WorldWideScience

Sample records for partial nephrectomy newer

  1. Anatomic partial nephrectomy: technique evolution.

    Science.gov (United States)

    Azhar, Raed A; Metcalfe, Charles; Gill, Inderbir S

    2015-03-01

    Partial nephrectomy provides equivalent long-term oncologic and superior functional outcomes as radical nephrectomy for T1a renal masses. Herein, we review the various vascular clamping techniques employed during minimally invasive partial nephrectomy, describe the evolution of our partial nephrectomy technique and provide an update on contemporary thinking about the impact of ischemia on renal function. Recently, partial nephrectomy surgical technique has shifted away from main artery clamping and towards minimizing/eliminating global renal ischemia during partial nephrectomy. Supported by high-fidelity three-dimensional imaging, novel anatomic-based partial nephrectomy techniques have recently been developed, wherein partial nephrectomy can now be performed with segmental, minimal or zero global ischemia to the renal remnant. Sequential innovations have included early unclamping, segmental clamping, super-selective clamping and now culminating in anatomic zero-ischemia surgery. By eliminating 'under-the-gun' time pressure of ischemia for the surgeon, these techniques allow an unhurried, tightly contoured tumour excision with point-specific sutured haemostasis. Recent data indicate that zero-ischemia partial nephrectomy may provide better functional outcomes by minimizing/eliminating global ischemia and preserving greater vascularized kidney volume. Contemporary partial nephrectomy includes a spectrum of surgical techniques ranging from conventional-clamped to novel zero-ischemia approaches. Technique selection should be tailored to each individual case on the basis of tumour characteristics, surgical feasibility, surgeon experience, patient demographics and baseline renal function.

  2. Robot-assisted partial nephrectomy in contemporary practice

    Directory of Open Access Journals (Sweden)

    Youssef S. Tanagho

    2013-01-01

    Full Text Available Laparoscopic renal surgery is associated with reduced blood loss, shorter hospital stay, enhanced cosmesis, and more rapid convalescence relative to open renal surgery. Laparoscopic partial nephrectomy is a minimally invasive, nephron-sparing alternative to laparoscopic radical nephrectomy for the management of small renal masses. While offering similar oncological outcomes to laparoscopic radical nephrectomy, the technical challenges and prolonged learning curve associated with laparoscopic partial nephrectomy limit its wider dissemination. Robot-assisted partial nephrectomy, although still an evolving procedure with no long-term data, has emerged as a viable alternative to laparoscopic partial nephrectomy, with favorable preliminary outcomes. This article provides an overview of the role of robot-assisted partial nephrectomy in the management of renal cell carcinoma. The clinical indications and principles of surgical technique for this procedure are discussed. The oncological, renal functional, and perioperative outcomes of robot-assisted partial nephrectomy are also evaluated, as are complication rates.

  3. Prospective study of robotic partial nephrectomy for renal cancer in Japan: Comparison with a historical control undergoing laparoscopic partial nephrectomy.

    Science.gov (United States)

    Tanaka, Kazushi; Teishima, Jun; Takenaka, Atsushi; Shiroki, Ryoichi; Kobayashi, Yasuyuki; Hattori, Kazunori; Kanayama, Hiro-Omi; Horie, Shigeo; Yoshino, Yasushi; Fujisawa, Masato

    2018-05-01

    To evaluate the outcomes of robotic partial nephrectomy compared with those of laparoscopic partial nephrectomy for T1 renal tumors in Japanese centers. Patients with a T1 renal tumor who underwent robotic partial nephrectomy were eligible for inclusion in the present study. The primary end-point consisted of three components: a negative surgical margin, no conversion to open or laparoscopic surgery and a warm ischemia time ≤25 min. We compared data from these patients with the data from a retrospective study of laparoscopic partial nephrectomy carried out in Japan. A total of 108 patients were registered in the present study; 105 underwent robotic partial nephrectomy. The proportion of patients who met the primary end-point was 91.3% (95% confidence interval 84.1-95.9%), which was significantly higher than 23.3% in the historical data. Major complications were seen in 19 patients (18.1%). The mean change in the estimated glomerular filtration rate in the operated kidney, 180 days postoperatively, was -10.8 mL/min/1.73 m 2 (95% confidence interval -12.3-9.4%). Robotic partial nephrectomy for patients with a T1 renal tumor is a safe, feasible and more effective operative method compared with laparoscopic partial nephrectomy. It can be anticipated that robotic partial nephrectomy will become more widely used in Japan in the future. © 2018 The Japanese Urological Association.

  4. Laparoscopic Partial Nephrectomy With Potassium-titanyl-phosphate Laser Versus Conventional Laparoscopic Partial Nephrectomy: An Animal Randomized Controlled Trial

    NARCIS (Netherlands)

    Rioja, Jorge; Morcillo, Esther; Novalbos, José P.; Sánchez-Hurtado, Miguel A.; Soria, Federico; Pérez-Duarte, Francisco; Díaz-Güemes Martín-Portugüés, Idoia; Laguna, Maria Pilar; Sánchez-Margallo, Francisco Miguel; Rodríguez-Rubio Cortadellas, Federico

    2017-01-01

    OBJECTIVE To explore the feasibility, safety, and short-term results of potassium-titanyl-phosphate (KTP) laser laparoscopic partial nephrectomy (KTP-LPN) vs conventional laparoscopic partial nephrectomy (C-LPN). MATERIALS AND METHODS Thirty large white female pigs were randomized to KTP-LPN or

  5. Laparoscopic partial nephrectomy for endophytic hilar tumors

    DEFF Research Database (Denmark)

    Di Pierro, G B; Tartaglia, N; Aresu, L

    2014-01-01

    To analyze feasibility and outcomes of laparoscopic partial nephrectomy (LPN) for endophytic hilar tumors in low-intermediate (ASA I-II) risk patients.......To analyze feasibility and outcomes of laparoscopic partial nephrectomy (LPN) for endophytic hilar tumors in low-intermediate (ASA I-II) risk patients....

  6. When Partial Nephrectomy is Unsuccessful: Understanding the Reasons for Conversion from Robotic Partial to Radical Nephrectomy at a Tertiary Referral Center.

    Science.gov (United States)

    Kara, Önder; Maurice, Matthew J; Mouracade, Pascal; Malkoç, Ercan; Dagenais, Julien; Nelson, Ryan J; Chavali, Jaya Sai S; Stein, Robert J; Fergany, Amr; Kaouk, Jihad H

    2017-07-01

    We sought to identify the preoperative factors associated with conversion from robotic partial nephrectomy to radical nephrectomy. We report the incidence of this event. Using our institutional review board approved database, we abstracted data on 1,023 robotic partial nephrectomies performed at our center between 2010 and 2015. Standard and converted cases were compared in terms of patients and tumor characteristics, and perioperative, functional and oncologic outcomes. Logistic regression analysis was done to identify predictors of radical conversion. The overall conversion rate was 3.1% (32 of 1,023 cases). The most common reasons for conversion were tumor involvement of hilar structures (8 cases or 25%), failure to achieve negative margins on frozen section (7 or 21.8%), suspicion of advanced disease (5 or 15.6%) and failure to progress (5 or 15.6%). Patients requiring conversion were older and had a higher Charlson score (both p partial nephrectomy cases had similar short-term oncologic outcomes but better renal functional preservation (p partial nephrectomy conversion to radical nephrectomy was 3.1%, including 2.2% of preoperatively anticipated nephrectomy cases. Increasing tumor size and complexity, and poor preoperative renal function are the main predictors of conversion. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. Zero ischemia laparoscopic partial thulium laser nephrectomy.

    LENUS (Irish Health Repository)

    Thomas, Arun Z

    2013-11-01

    Laser technology presents a promising alternative to achieve tumor excision and renal hemostasis with or without hilar occlusion, yet its use in partial nephrectomy has not been significantly evaluated. We prospectively evaluated the thulium:yttrium-aluminum-garnet laser in laparoscopic partial nephrectomy (LPN) in our institution over a 1-year period.

  8. Prospective study on laser-assisted laparascopic partial nephrectomy

    Science.gov (United States)

    Sroka, Ronald; Hennig, Georg; Zilinberg, Katja; Khoder, Wael Y.

    2012-02-01

    Introduction: Developments in laparoscopic partial nephrectomy (LPN) opened a demand for surgical tools compatible with laparoscopic manipulations to make laser assisted technique safe, feasible and reproducible. Warm ischemia and bleeding during laparoscopic partial nephrectomy place technical constraints on surgeons. Therefore it was the aim to develop a safe and effective laser assisted partial nephrectomy technique without need for ischemia. Patients and methods: A diode laser emitting light at 1318nm in cw mode was coupled into a bare fibre (core diameter 600 μm) thus able to transfer up to 100W to the tissue. After dry lab experience, a total of 10 patients suffering from kidney malformations underwent laparoscopic/retroperitoneoscopic partial nephrectomy. Clinically, postoperative renal function and serum c-reactive protein (CRP) were monitored. Laser induced coagulation depth and effects on resection margins were evaluated. Demographic, clinical and follow-up data are presented. Using a commercial available fibre guidance instrument for lanringeal intervention, the demands on an innovative laser fibre guidance instrument for the laser assisted laparoscopic partial nephrectomy (LLPN) are summarized. Results: Overall, all laparascopic intervention were succesfull and could be performed without conversion to open surgery. Mean operative time and mean blood loss were comparable to conventional open and laparascopic approaches. Laser assisted resection of the kidney tissue took max 15min. After extirpation of the tumours all patients showed clinical favourable outcome during follow up period. Tumour sizes were measured to be up 5cm in diameter. The depth of the coagulation on the removed tissue ranged between laser assisted coagulated after removal. The sealing of the surface was induced by a slightly larger coagulation margin, but could not measured so far. Based on this experiences a simple and easy to use instrument described serving also for suction and

  9. Robot-assisted laparoscopic partial nephrectomy: Current review of the technique and literature.

    Science.gov (United States)

    Singh, Iqbal

    2009-10-01

    To visit the operative technique and to review the current published English literature on the technique, and outcomes following robot-assisted laparoscopic partial nephrectomy (RPN). We searched the published English literature and the PubMed(()) for published series of 'robotic partial nephrectomy' (RPN) using the keywords; robot, robot-assisted laparoscopic partial nephrectomy, laparoscopic partial nephrectomy, partial nephrectomy and laparoscopic surgery. The search yielded 15 major selected series of 'robotic partial nephrectomy'; these were reviewed, tracked and analysed in order to determine the current status and role of RPN in the management of early renal neoplasm(s), as a minimally invasive surgical alternative to open partial nephrectomy. A review of the initial peri-operative outcome of the 350 cases of select series of RPN reported in published English literature revealed a mean operating time, warm ischemia time, estimated blood loss and hospital stay, of 191 minutes, 25 minutes, 162 ml and 2.95 days, respectively. The overall computed mean complication rate of RPN in the present select series was about 7.4%. RPN is a safe, feasible and effective minimally invasive surgical alternative to laparoscopic partial nephrectomy for early stage (T(1)) renal neoplasm(s). It has acceptable initial renal functional outcomes without the increased risk of major complications in experienced hands. Prospective randomised, controlled, comparative clinical trials with laparoscopic partial nephrectomy (LPN) are the need of the day. While the initial oncological outcomes of RPN appear to be favourable, long-term data is awaited.

  10. Robot-assisted partial nephrectomy in contemporary practice

    Energy Technology Data Exchange (ETDEWEB)

    Tanagho, Youssef S.; Bhayani, Sam B.; Figenshau, Robert S., E-mail: tanaghoy@wudosis.wustl.edu [Division of Urologic Surgery, Washington University School of Medicine, St. Louis, MO (United States)

    2013-01-11

    Laparoscopic renal surgery is associated with reduced blood loss, shorter hospital stay, enhanced cosmesis, and more rapid convalescence relative to open renal surgery. Laparoscopic partial nephrectomy (LPN) is a minimally invasive, nephron-sparing alternative to laparoscopic radical nephrectomy (RN) for the management of small renal masses. While offering similar oncological outcomes to laparoscopic RN, the technical challenges and prolonged learning curve associated with LPN limit its wider dissemination. Robot-assisted partial nephrectomy (RAPN), although still an evolving procedure with no long-term data, has emerged as a viable alternative to LPN, with favorable preliminary outcomes. This article provides an overview of the role of RAPN in the management of renal cell carcinoma. The clinical indications and principles of surgical technique for this procedure are discussed. The oncological, renal functional, and perioperative outcomes of RAPN are also evaluated, as are complication rates.

  11. Robot-assisted partial nephrectomy in contemporary practice

    International Nuclear Information System (INIS)

    Tanagho, Youssef S.; Bhayani, Sam B.; Figenshau, Robert S.

    2013-01-01

    Laparoscopic renal surgery is associated with reduced blood loss, shorter hospital stay, enhanced cosmesis, and more rapid convalescence relative to open renal surgery. Laparoscopic partial nephrectomy (LPN) is a minimally invasive, nephron-sparing alternative to laparoscopic radical nephrectomy (RN) for the management of small renal masses. While offering similar oncological outcomes to laparoscopic RN, the technical challenges and prolonged learning curve associated with LPN limit its wider dissemination. Robot-assisted partial nephrectomy (RAPN), although still an evolving procedure with no long-term data, has emerged as a viable alternative to LPN, with favorable preliminary outcomes. This article provides an overview of the role of RAPN in the management of renal cell carcinoma. The clinical indications and principles of surgical technique for this procedure are discussed. The oncological, renal functional, and perioperative outcomes of RAPN are also evaluated, as are complication rates.

  12. Robot-assisted laparoscopic partial nephrectomy: Current review of the technique and literature

    Directory of Open Access Journals (Sweden)

    Singh Iqbal

    2009-01-01

    Full Text Available Aim: To visit the operative technique and to review the current published English literature on the technique, and outcomes following robot-assisted laparoscopic partial nephrectomy (RPN. Materials and Methods: We searched the published English literature and the PubMed (TM for published series of ′robotic partial nephrectomy′ (RPN using the keywords; robot, robot-assisted laparoscopic partial nephrectomy, laparoscopic partial nephrectomy, partial nephrectomy and laparoscopic surgery. Results: The search yielded 15 major selected series of ′robotic partial nephrectomy′; these were reviewed, tracked and analysed in order to determine the current status and role of RPN in the management of early renal neoplasm(s, as a minimally invasive surgical alternative to open partial nephrectomy. A review of the initial peri-operative outcome of the 350 cases of select series of RPN reported in published English literature revealed a mean operating time, warm ischemia time, estimated blood loss and hospital stay, of 191 minutes, 25 minutes, 162 ml and 2.95 days, respectively. The overall computed mean complication rate of RPN in the present select series was about 7.4%. Conclusions: RPN is a safe, feasible and effective minimally invasive surgical alternative to laparoscopic partial nephrectomy for early stage (T 1 renal neoplasm(s. It has acceptable initial renal functional outcomes without the increased risk of major complications in experienced hands. Prospective randomised, controlled, comparative clinical trials with laparoscopic partial nephrectomy (LPN are the need of the day. While the initial oncological outcomes of RPN appear to be favourable, long-term data is awaited.

  13. Ex-vivo partial nephrectomy after living donor nephrectomy: Surgical technique for expanding kidney donor pool

    Directory of Open Access Journals (Sweden)

    Yaw A Nyame

    2017-01-01

    Full Text Available Renal transplantation has profound improvements in mortality, morbidity, and overall quality of life compared to renal replacement therapy. This report aims to illustrate the use of ex-vivo partial nephrectomy in a patient with a renal angiomyolipoma prior to living donor transplantation. The surgical outcomes of the donor nephrectomy and recipient transplantation are reported with 2 years of follow-up. Both the donor and recipient are healthy and without any significant comorbidities. In conclusion, urologic techniques such as partial nephrectomy can be used to expand the living donor pool in carefully selected and well informed transplant recipients. Our experience demonstrated a safe and positive outcome for both the recipient and donor, and is consistent with other reported outcomes in the literature.

  14. Robotic partial nephrectomy for complex renal tumors: surgical technique.

    Science.gov (United States)

    Rogers, Craig G; Singh, Amar; Blatt, Adam M; Linehan, W Marston; Pinto, Peter A

    2008-03-01

    Laparoscopic partial nephrectomy requires advanced training to accomplish tumor resection and renal reconstruction while minimizing warm ischemia times. Complex renal tumors add an additional challenge to a minimally invasive approach to nephron-sparing surgery. We describe our technique, illustrated with video, of robotic partial nephrectomy for complex renal tumors, including hilar, endophytic, and multiple tumors. Robotic assistance was used to resect 14 tumors in eight patients (mean age: 50.3 yr; range: 30-68 yr). Three patients had hereditary kidney cancer. All patients had complex tumor features, including hilar tumors (n=5), endophytic tumors (n=4), and/or multiple tumors (n=3). Robotic partial nephrectomy procedures were performed successfully without complications. Hilar clamping was used with a mean warm ischemia time of 31 min (range: 24-45 min). Mean blood loss was 230 ml (range: 100-450 ml). Histopathology confirmed clear-cell renal cell carcinoma (n=3), hybrid oncocytic tumor (n=2), chromophobe renal cell carcinoma (n=2), and oncocytoma (n=1). All patients had negative surgical margins. Mean index tumor size was 3.6 cm (range: 2.6-6.4 cm). Mean hospital stay was 2.6 d. At 3-mo follow-up, no patients experienced a statistically significant change in serum creatinine or estimated glomerular filtration rate and there was no evidence of tumor recurrence. Robotic partial nephrectomy is safe and feasible for select patients with complex renal tumors, including hilar, endophytic, and multiple tumors. Robotic assistance may facilitate a minimally invasive, nephron-sparing approach for select patients with complex renal tumors who might otherwise require open surgery or total nephrectomy.

  15. Delayed Partial Nephrectomy for Hydronephrosis After Renal Trauma.

    Science.gov (United States)

    Setia, Shaan; Jackson, Jessica Nicole; Herndon, C D Anthony; Corbett, Sean T

    2017-03-01

    Delayed sequelae following conservative management of renal trauma in the pediatric population are uncommon. Reports of delayed operations to manage these sequelae are even less common. Here we present the case of a 16-year-old male patient who had delayed development of upper urinary tract obstruction with recurrent infections following high-grade renal trauma managed conservatively. Ultimately, he required a robotic-assisted partial nephrectomy 2 years after initial nonoperative management. This is unique as no prior studies to our knowledge have described delayed hydronephrosis and delayed partial nephrectomy over a year following renal trauma. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Review of laparoscopic partial nephrectomy in the treatment of renal tumors, T1 stadium in adults

    International Nuclear Information System (INIS)

    Zamora Montes de Oca, Maria Jose

    2012-01-01

    The T1 renal cancer in adults is made known; incidence, characteristics and management. Renal cell carcinoma has been the most common malignancy of the kidney, percentage is close to three percent of solid tumors of adults. The treatments for this tumor are analyzed: open radical nephrectomy, laparoscopic radical nephrectomy, open partial nephrectomy and laparoscopic partial nephrectomy. Laparoscopic partial nephrectomy has represented an alternative option acceptable, safely and with good oncological and surgical outcomes for patients, as it is used to conserve nephrons and simultaneously to resect the tumor of a complete form promoting in the future the patient present a good renal function. Additionally, a adequate oncological control has reduced the risk of submit postoperative renal failure. An evolution of laparoscopic partial nephrectomy is presented determining the procedure for renal tumors in state T1 in the adults [es

  17. Open Partial Nephrectomy in Renal Cancer: A Feasible Gold Standard Technique in All Hospitals

    Directory of Open Access Journals (Sweden)

    J. M. Cozar

    2008-01-01

    Full Text Available Introduction. Partial nephrectomy (PN is playing an increasingly important role in localized renal cell carcinoma (RCC as a true alternative to radical nephrectomy. With the greater experience and expertise of surgical teams, it has become an alternative to radical nephrectomy in young patients when the tumor diameter is 4 cm or less in almost all hospitals since cancer-specific survival outcomes are similar to those obtained with radical nephrectomy. Materials and Methods. The authors comment on their own experience and review the literature, reporting current indications and outcomes including complications. The surgical technique of open partial nephrectomy is outlined. Conclusions. Nowadays, open PN is the gold standard technique to treat small renal masses, and all nonablative techniques must pass the test of time to be compared to PN. It is not ethical for patients to undergo radical surgery just because the urologists involved do not have adequate experience with PN. Patients should be involved in the final treatment decision and, when appropriate, referred to specialized centers with experience in open or laparoscopic partial nephrectomies.

  18. Robotic-assisted laparoscopic partial nephrectomy: initial experience in Brazil and a review of the literature

    Directory of Open Access Journals (Sweden)

    Carlo Camargo Passerotti

    2012-02-01

    Full Text Available CONTEXT AND PURPOSE: Partial nephrectomy has become the standard of care for renal tumors less than 4 cm in diameter. Controversy still exists, however, regarding the best surgical approach, especially when minimally invasive techniques are taken into account. Robotic-assisted laparoscopic partial nephrectomy (RALPN has emerged as a promising technique that helps surgeons achieve the standards of open partial nephrectomy care while offering a minimally invasive approach. The objective of the present study was to describe our initial experience with robotic-assisted laparoscopic partial nephrectomy and extensively review the pertinent literature. MATERIALS AND METHODS: Between August 2009 and February 2010, eight consecutive selected patients with contrast enhancing renal masses observed by CT were submitted to RALPN in a private institution. In addition, we collected information on the patients' demographics, preoperative tumor characteristics and detailed operative, postoperative and pathological data. In addition, a PubMed search was performed to provide an extensive review of the robotic-assisted laparoscopic partial nephrectomy literature. RESULTS: Seven patients had RALPN on the left or right sides with no intraoperative complications. One patient was electively converted to a robotic-assisted radical nephrectomy. The operative time ranged from 120 to 300 min, estimated blood loss (EBL ranged from 75 to 400 mL and, in five cases, the warm ischemia time (WIT ranged from 18 to 32 min. Two patients did not require any clamping. Overall, no transfusions were necessary, and there were no intraoperative complications or adverse postoperative clinical events. All margins were negative, and all patients were disease-free at the 6-month follow-up. CONCLUSIONS: Robotic-assisted laparoscopic partial nephrectomy is a feasible and safe approach to small renal cortical masses.Further prospective studies are needed to compare open partial nephrectomy with

  19. Robotic-assisted partial Nephrectomy: initial experience in South America

    Directory of Open Access Journals (Sweden)

    Gustavo C. Lemos

    2011-08-01

    Full Text Available OBJECTIVE:To report the initial outcomes of robotic-assisted partial nephrectomy in a tertiary center in South America. MATERIAL AND METHODS: From 11/2008 to 12/2009, a total of 16 transperitoneal robotic-assisted partial nephrectomies were performed in 15 patients to treat 18 kidney tumors. One patient with bilateral tumor had two procedures, while two patients with two synchronous unilateral tumors had a single operation to remove them. Eleven (73% patients were male and the right kidney was affected in 7 (46% patients. The median patient age and tumor size were 57 years old and 30 mm, respectively. Five (28% tumors were hilar and/or centrally located. RESULTS: The median operative time, warm ischemia time and estimated blood loss was 140 min, 27 min and 120 mL, respectively. Blood transfusion was required in one patient with bilateral tumor, and one additional pyelolithotomy was performed due to a 15mm stone located in the renal pelvis. The histopathology analysis showed 15 (83% malignant tumors, which 10 (67% were clear cell carcinoma. The median hospital stay was 72 hrs and no major complication was observed. CONCLUSION: Robotic-assisted partial nephrectomy is safe and represents a valuable option to perform minimally invasive nephron-sparing surgery.

  20. Robot-assisted laparoscopic versus open partial nephrectomy in patients with chronic kidney disease: A propensity score-matched comparative analysis of surgical outcomes.

    Science.gov (United States)

    Takagi, Toshio; Kondo, Tsunenori; Tachibana, Hidekazu; Iizuka, Junpei; Omae, Kenji; Kobayashi, Hirohito; Yoshida, Kazuhiko; Tanabe, Kazunari

    2017-07-01

    To compare surgical outcomes between robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy in patients with chronic kidney disease. Of 550 patients who underwent partial nephrectomy between 2012 and 2015, 163 patients with T1-2 renal tumors who had an estimated glomerular filtration rate between 30 and 60 mL/min/1.73 m 2 , and underwent robot-assisted laparoscopic partial nephrectomy or open partial nephrectomy were retrospectively analyzed. To minimize selection bias between the two surgical methods, patient variables were adjusted by 1:1 propensity score matching. The present study included 75 patients undergoing robot-assisted laparoscopic partial nephrectomy and 88 undergoing open partial nephrectomy. After propensity score matching, 40 patients were included in each operative group. The mean preoperative estimated glomerular filtration rate was 49 mL/min/1.73 m 2 . The mean ischemia time was 21 min in robot-assisted laparoscopic partial nephrectomy (warm ischemia) and 35 min in open partial nephrectomy (cold ischemia). Preservation of the estimated glomerular filtration rate 3-6 months postoperatively was not significantly different between robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy (92% vs 91%, P = 0.9348). Estimated blood loss was significantly lower in the robot-assisted laparoscopic partial nephrectomy group than in the open partial nephrectomy group (104 vs 185 mL, P = 0.0025). The postoperative length of hospital stay was shorter in the robot-assisted laparoscopic partial nephrectomy group than in the open partial nephrectomy group (P negative surgical margin status were not significantly different between the two groups. In our experience, robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy provide similar outcomes in terms of functional preservation and perioperative complications among patients with chronic kidney disease. However, a lower estimated blood loss and

  1. Different methods of hilar clamping during partial nephrectomy: Impact on renal function.

    Science.gov (United States)

    Lee, Jeong Woo; Kim, Hwanik; Choo, Minsoo; Park, Yong Hyun; Ku, Ja Hyeon; Kim, Hyeon Hoe; Kwak, Cheol

    2014-03-01

    To evaluate the impact of different hilar clamping methods on changes in renal function after partial nephrectomy. We analyzed the clinical data of 369 patients who underwent partial nephrectomy for a single renal tumor of size ≤4.0 cm and a normal contralateral kidney. Patients were separated into three groups depending on hilar clamping method: non-clamping, cold ischemia and warm ischemia. Estimated glomerular filtration rate was examined at preoperative, nadir and 1 year postoperatively. Percent change in estimated glomerular filtration rate was used as the parameter to assess the renal functional outcome. Percent change in nadir estimated glomerular filtration rate in the non-clamping group was significantly less compared with the cold ischemia and warm ischemia groups (P hilar clamping (both warm ischemia and cold ischemia) were significantly associated with percent change in nadir estimated glomerular filtration rate, but not in 1-year estimated glomerular filtration rate. Non-clamping partial nephrectomy results in a lower percent change in nadir estimated glomerular filtration rate, whereas it carries an estimated glomerular filtration rate change at 1 year that is similar to partial nephrectomy with cold ischemia and warm ischemia. Cold ischemia and warm ischemia provide a similar effect on renal function. Therefore, when hilar clamping is required, minimization of ischemia time is necessary. © 2013 The Japanese Urological Association.

  2. Efficiency and Reliability of Laparoscopic Partial Nephrectomy for Renal Tumors Larger than 4 cm

    Directory of Open Access Journals (Sweden)

    Faruk Özgör

    2015-03-01

    Full Text Available Aim: To evaluate safety and efficiency of laparoscopic partial nephrectomy for renal tumors larger than 4 cm. Methods: We retrospectivelly evaluated the medical records of 65 patients who underwent laparascopic partial nephrectomy between May 2009 and June 2013 in our clinic. The patients were divided into two groups according to tumor size. Patients with a tumor 4 cm were included in group 1 (n=45 and group 2 (n=20, respectively. Demographic, perioperative and postoperative parameters were compared between the groups. Histopathological examination and surgical margin status were also evaluated. Results: The mean age of the patients was 59.2±10.9 (range: 26- 81 years. The mean tumor size and the mean RENAL nephrometry score were significantly higher in group 2 than in group 1. The mean operation time and warm ischemia time were similar between groups but estimated blood loss and transfusion requirement were significantly higher in group 2. Convertion to open surgery was seen two patients in group 2 and one patient in group 1. Only one patient underwent radical nephrectomy for uncontrolled bleeding in group 2. There was no difference in preoperative and 3-month postoperative serum creatinine levels between the groups. The incidence of positive surgical margin was 0% and 5% in group 1 and group 2, respectively. Conclusion: Laparoscopic partial nephrectomy for renal tumors is an effective and feasible procedure with acceptable oncologic results. However, tranfusion rate and requiremet of pelvicaliceal system repair were more common in patients with tumor >4 cm. (The Medical Bulletin of Haseki 2015; 53:30-5

  3. Hospitalization for partial nephrectomy was not associated with intrathecal opioid analgesia: Retrospective analysis.

    Science.gov (United States)

    Weingarten, Toby N; Del Mundo, Serena B; Yeoh, Tze Yeng; Scavonetto, Federica; Leibovich, Bradley C; Sprung, Juraj

    2014-10-01

    The aim of this retrospective study is to test the hypothesis that the use of spinal analgesia shortens the length of hospital stay after partial nephrectomy. We reviewed all patients undergoing partial nephrectomy for malignancy through flank incision between January 1, 2008, and June 30, 2011. We excluded patients who underwent tumor thrombectomy, used sustained-release opioids, or had general anesthesia supplemented by epidural analgesia. Patients were grouped into "spinal" (intrathecal opioid injection for postoperative analgesia) versus "general anesthetic" group, and "early" discharge group (within 3 postoperative days) versus "late" group. Association between demographics, patient physical status, anesthetic techniques, and surgical complexity and hospital stay were analyzed using multivariable logistic regression analysis. Of 380 patients, 158 (41.6%) were discharged "early" and 151 (39.7%) were "spinal" cases. Both spinal and early discharge groups had better postoperative pain control and used less postoperative systemic opioids. Spinal analgesia was associated with early hospital discharge, odds ratio 1.52, (95% confidence interval 1.00-2.30), P = 0.05, but in adjusted analysis was no longer associated with early discharge, 1.16 (0.73-1.86), P = 0.52. Early discharge was associated with calendar year, with more recent years being associated with early discharge. Spinal analgesia combined with general anesthesia was associated with improved postoperative pain control during the 1(st) postoperative day, but not with shorter hospital stay following partial nephrectomy. Therefore, unaccounted practice changes that occurred during more recent times affected hospital stay.

  4. External Validation of Contact Surface Area as a Predictor of Postoperative Renal Function in Patients Undergoing Partial Nephrectomy.

    Science.gov (United States)

    Haifler, Miki; Ristau, Benjamin T; Higgins, Andrew M; Smaldone, Marc C; Kutikov, Alexander; Zisman, Amnon; Uzzo, Robert G

    2017-09-20

    We sought to externally validate a mathematical formula for tumor contact surface area as a predictor of postoperative renal function in patients undergoing partial nephrectomy for renal cell carcinoma. We queried a prospectively maintained kidney cancer database for patients who underwent partial nephrectomy between 2014 and 2016. Contact surface area was calculated using data obtained from preoperative cross-sectional imaging. The correlation between contact surface area and perioperative variables was examined. The correlation between postoperative renal functional outcomes, contact surface area and the R.E.N.A.L. (radius, exophytic/endophytic properties, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines and tumor touches main renal artery or vein) nephrometry score was also assessed. A total of 257 patients who underwent partial nephrectomy had sufficient data to enter the study. Median contact surface area was 14.5 cm 2 (IQR 6.2-36) and the median nephrometry score was 9 (IQR 7-10). Spearman correlation analysis showed that contact surface area correlated with estimated blood loss (r s = 0.42, p contact surface area and nephrometry score were independent predictors of the absolute change in the estimated glomerular filtration rate (each p contact surface area was a better predictor of a greater than 20% postoperative decline in the estimated glomerular filtration rate compared with the nephrometry score (AUC 0.94 vs 0.80). Contact surface area correlated with the change in postoperative renal function after partial nephrectomy. It can be used in conjunction with the nephrometry score to counsel patients about the risk of renal functional decline after partial nephrectomy. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. 30-day hospital readmission after robotic partial nephrectomy--are we prepared for Medicare readmission reduction program?

    Science.gov (United States)

    Brandao, Luis Felipe; Zargar, Homayoun; Laydner, Humberto; Akca, Oktay; Autorino, Riccardo; Ko, Oliver; Samarasekera, Dinesh; Li, Jianbo; Rabets, John; Krishnan, Jayram; Haber, Georges-Pascal; Kaouk, Jihad; Stein, Robert J

    2014-09-01

    After CMS introduced the concept of the Hospital Readmissions Reduction Program, hospitals and health care centers became financially penalized for exceeding specific readmission rates. We retrospectively reviewed our institutional review board approved database of patients undergoing robotic partial nephrectomy at our institution and included in our analysis patients who were readmitted to any hospital as an inpatient stay within 30 days from discharge home after robotic partial nephrectomy. From March 2006 to March 2013 a total of 627 patients underwent robotic partial nephrectomy at our center and 28 (4.46%) were readmitted within 30 days of surgery. Postoperative bleeding was responsible for 8 (28.5%) readmissions. Pulmonary embolism was reported in 3 cases and retroperitoneal abscess was diagnosed in 2. Urinary leak requiring surgical intervention developed in 2 patients, pneumonia was diagnosed in 2 and 2 patients were readmitted for chest pain. Overall 9 (32.1%) patients presented with major complications requiring intervention. On multivariable analysis Charlson comorbidity index score was the only factor significantly associated with a higher 30-day readmission rate (p = 0.03). If the Charlson score was 5 or greater the chance of hospital readmission would be 2.7 times higher. Increased comorbidity, specifically a Charlson score of 5 or greater, was the only significant predictor of a higher incidence of 30-day readmission. This information can be useful in counseling patients regarding robotic partial nephrectomy and in determining baseline rates if CMS expands the number of conditions they evaluate for excess 30-day readmissions. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. [A new technique for ensuring negative surgical margins during partial nephrectomy: the ex vivo ultrasound control].

    Science.gov (United States)

    Desmonts, A; Tillou, X; Le Gal, S; Secco, M; Orczyk, C; Bensadoun, H; Doerfler, A

    2013-10-01

    To evaluate the feasibility and the efficiency of intraoperative ex vivo ultrasound of resection margins in patients undergoing partial nephrectomy by urologist. Patients undergoing partial nephrectomy from July 2010 to November 2012 for T1-T2 renal tumors were included in analysis. Tumor margin status was immediately determined by ex vivo ultrasound done by the surgeon himself. Results were compared with margin status on definitive pathological evaluation. A total of 26 men and 15 women with a median age of 61 (30-82) years old were included in analysis. Intraoperative ex vivo ultrasound revealed negative surgical margins in 38 cases and positive margins in two. Final pathological results revealed negative margins in all except one case. Ultrasound sensitivity and specificity were 100% and 97%, respectively. Mean ultrasound duration was 1minute±1. Mean tumor and margin sizes were 3.4±1.8cm and 2.38±1.76mm, respectively. Intraoperative ex vivo ultrasound of resection margins in patients undergoing partial nephrectomy by a urologist seemed to be feasible, efficient and easy. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  7. Robotic partial nephrectomy for renal cell carcinomas with venous tumor thrombus.

    Science.gov (United States)

    Abaza, Ronney; Angell, Jordan

    2013-06-01

    To describe the first report of robotic partial nephrectomies (RPNs) for renal cell carcinoma (RCC) with venous tumor thrombus (VTT). Partial nephrectomy for RCC extending into the renal vein has been described in limited fashion, but such a complex procedure has not previously been reported in minimally-invasive fashion. We demonstrate the feasibility of robotic nephron-sparing surgery despite vein thrombi and the results of the initial four highly-selected patients to have undergone this novel procedure. Two patients underwent RPN for RCC with VTT involving intraparenchymal vein branches, and 2 others had VTT involving the main renal vein. Mean patient age was 65 years (range 50-74 years). Mean tumor size was 7.75 cm (range 4.3-12.8 cm) with mean RENAL (radius, exophytic/endophytic, nearness to collecting system, anterior/posterior, and location) nephrometry score of 9.75 (range 8-12). Mean warm ischemia time was 24.2 minutes (range 19-27 minutes) and mean estimated blood loss was 168.8 mL (range 100-300 mL). No patients required transfusion, and there were no intraoperative complications. No patients required conversion to open or standard laparoscopic surgery. All 4 patients were discharged home on the first postoperative day. A single postoperative complication occurred in 1 patient who was readmitted with an ileus that resolved spontaneously. All patients had negative surgical margins. Two patients developed metastatic disease on surveillance imaging. RPN in patients with VTT is safe and feasible in selected patients. Given the risk of metastatic disease in patients with pathologic stage T3a RCC, the role of nephron sparing requires further evaluation such that radical nephrectomy remains the standard of care. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Selective Arterial Clamping Versus Hilar Clamping for Minimally Invasive Partial Nephrectomy.

    Science.gov (United States)

    Yezdani, Mona; Yu, Sue-Jean; Lee, David I

    2016-05-01

    Partial nephrectomy has become an accepted treatment of cT1 renal masses as it provides improved long-term renal function compared to radical nephrectomy (Campbell et al. J Urol. 182:1271-9, 2009). Hilar clamping is utilized to help reduce bleeding and improve visibility during tumor resection. However, concern over risk of kidney injury with hilar clamping has led to new techniques to reduce length of warm ischemia time (WIT) during partial nephrectomy. These techniques have progressed over the years starting with early hilar unclamping, controlled hypotension during tumor resection, selective arterial clamping, minimal margin techniques, and off-clamp procedures. Selective arterial clamping has progressed significantly over the years. The main question is what are the exact short- and long-term renal effects from increasing clamp time. Moreover, does it make sense to perform these more time-consuming or more complex procedures if there is no long-term preservation of kidney function? More recent studies have shown no difference in renal function 6 months from surgery when selective arterial clamping or even hilar clamping is employed, although there is short-term improved decline in estimated glomerular filtration rate (eGFR) with selective clamping and off-clamp techniques (Komninos et al. BJU Int. 115:921-8, 2015; Shah et al. 117:293-9, 2015; Kallingal et al. BJU Int. doi: 10.1111/bju.13192, 2015). This paper reviews the progression of total hilar clamping to selective arterial clamping (SAC) and the possible difference its use makes on long-term renal function. SAC may be attempted based on surgeon's decision-making, but may be best used for more complex, larger, more central or hilar tumors and in patients who have renal insufficiency at baseline or a solitary kidney.

  9. Hybrid laparoscopic and robotic ultrasound-guided radiofrequency ablation-assisted clampless partial nephrectomy.

    Science.gov (United States)

    Nadler, Robert B; Perry, Kent T; Smith, Norm D

    2009-07-01

    To describe a clampless approach made possible by creating an avascular plane of tissue with radiofrequency ablation. Laparoscopic partial nephrectomy is slowly gaining acceptance as a method to treat small (generator. Typically, we used a power setting of 50 W but have found settings as low as 25 W necessary to provide hemostasis for larger vessels. The tumor was then sharply excised with a negative margin using robotic scissors and electrocautery to facilitate tissue cutting. Retrograde injection of methylthioninium chloride and saline through an externalized ureteral catheter allowed for precise sutured closure of the collecting system. FloSeal and BioGlue were then applied, making surgical bolsters or parenchymal sutures unnecessary. Intraoperative histologic evaluation of the surgical margin and repeat resection of the tumor bed was possible because the renal hilum was not clamped, and no warm ischemia was used. This technique, which combines the improving technologies of robotic surgery, intraoperative laparoscopic ultrasonography, and radiofrequency ablation, might make more surgeons comfortable with the intricacies of laparoscopic suturing and eliminate prolonged warm ischemia times. Overall, this method should result in more patients being able to undergo minimally invasive laparoscopic partial nephrectomy.

  10. Safety and Efficacy of transarterial nephrectomy as an alternative to surgical nephrectomy

    International Nuclear Information System (INIS)

    Cho, Jooae; Shin, Ji Hoon; Yoon, Hyun Ki; Ko, Gi Young; Gwon, Dong Il; Ko, Heung Kyu; Kim, Jin Hyoung; Sung, Kyu Bo

    2014-01-01

    To evaluate the safety and efficacy of transarterial nephrectomy, i.e., complete renal artery embolization, as an alternative to surgical nephrectomy. This retrospective study included 11 patients who underwent transarterial nephrectomy due to a high risk of surgical nephrectomy or their refusal to undergo surgery during the period from April 2002 to February 2013. Medical records and radiographic images were reviewed retrospectively to collect information regarding underlying etiologies, clinical presentations and embolization outcomes. The underlying etiologies for transarterial nephrectomy included recurrent hematuria (chronic transplant rejection [n = 3], arteriovenous malformation or fistula [n = 3], angiomyolipoma [n = 1], or end-stage renal disease [n = 1]), inoperable renal or ureteral injury (n = 2), and ectopic kidney with urinary incontinence (n 1). The technical success rate was 100%, while clinical success was achieved in eight patients (72.7%). Subsequent surgical nephrectomy was required for three patients due to an incomplete nephrectomy effect (n = 2) or necrotic pyelonephritis (n = 1). Procedure-related complications were post-infarction syndrome in one patient and necrotic pyelonephritis in another patient. Of four patients with follow-up CT, four showed renal atrophy and two showed partial renal enhancement. No patient developed a procedure-related hypertension. Transarterial nephrectomy may be a safe and effective alternative to surgical nephrectomy in patients with high operative risks.

  11. Safety and Efficacy of transarterial nephrectomy as an alternative to surgical nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jooae; Shin, Ji Hoon; Yoon, Hyun Ki; Ko, Gi Young; Gwon, Dong Il; Ko, Heung Kyu; Kim, Jin Hyoung; Sung, Kyu Bo [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2014-08-15

    To evaluate the safety and efficacy of transarterial nephrectomy, i.e., complete renal artery embolization, as an alternative to surgical nephrectomy. This retrospective study included 11 patients who underwent transarterial nephrectomy due to a high risk of surgical nephrectomy or their refusal to undergo surgery during the period from April 2002 to February 2013. Medical records and radiographic images were reviewed retrospectively to collect information regarding underlying etiologies, clinical presentations and embolization outcomes. The underlying etiologies for transarterial nephrectomy included recurrent hematuria (chronic transplant rejection [n = 3], arteriovenous malformation or fistula [n = 3], angiomyolipoma [n = 1], or end-stage renal disease [n = 1]), inoperable renal or ureteral injury (n = 2), and ectopic kidney with urinary incontinence (n 1). The technical success rate was 100%, while clinical success was achieved in eight patients (72.7%). Subsequent surgical nephrectomy was required for three patients due to an incomplete nephrectomy effect (n = 2) or necrotic pyelonephritis (n = 1). Procedure-related complications were post-infarction syndrome in one patient and necrotic pyelonephritis in another patient. Of four patients with follow-up CT, four showed renal atrophy and two showed partial renal enhancement. No patient developed a procedure-related hypertension. Transarterial nephrectomy may be a safe and effective alternative to surgical nephrectomy in patients with high operative risks.

  12. Better recovery of kidney function in patients with de novo chronic kidney disease after partial nephrectomy compared with those with pre-existing chronic kidney disease.

    Science.gov (United States)

    Takagi, Toshio; Kondo, Tsunenori; Iizuka, Junpei; Omae, Kenji; Kobayashi, Hirohito; Hashimoto, Yasunobu; Yoshida, Kazuhiko; Tanabe, Kazunari

    2014-06-01

    We compared kidney functional recovery between patients with pre-existing chronic kidney disease, those with de novo chronic kidney disease and those with normal kidney function, after partial nephrectomy. A total of 311 patients who underwent partial nephrectomy at Tokyo Women's Medical University Hospital, Tokyo, Japan, between January 2004 and July 2011 with sufficient kidney functional data participated in the study. Patients with pre-existing chronic kidney disease (group1: 78 patients) were defined as those with estimated glomerular filtration rate under 60 mL/min/m(2) before partial nephrectomy. Patients with de novo chronic kidney disease (group 2: 49) were defined as those with estimated glomerular filtration rate over 60 mL/min/m(2) before surgery and who developed estimated glomerular filtration rate under 60 mL/min/m(2) 3 months after partial nephrectomy. Normal patients (group 3: 184) were defined as those with estimated glomerular filtration rate over 60 mL/min/m(2) both before and after partial nephrectomy. Group 1 was associated with older age and higher comorbidity, including hypertension and diabetes mellitus, compared with other groups. R.E.N.A.L. score was not significantly different between the groups. Although the percent change of estimated glomerular filtration rate between the preoperative period and 3 months after partial nephrectomy in group 2 was significantly decreased compared with that in other groups (group 1: -6.8%, group 2: -18%, group 3: -7.3%), the renal functional recovery between 3 and 12 months after partial nephrectomy in group 2 was better than that in other groups (group 1: -0.5%, group 2: 5.6%, group 3: -0.4%). Patients with de novo chronic kidney disease had better kidney functional recovery than the other two groups, which might suggest that they were surgically assaulted and developed chronic kidney disease in the early postoperative period, and were essentially different from those with pre-existing chronic kidney

  13. Retroperitoneal approach for robot-assisted partial nephrectomy: technique and early outcomes

    Directory of Open Access Journals (Sweden)

    A. Porreca

    Full Text Available ABSTRACT Objectives The aim of our study is to present early outcomes of our series of retroperitoneal-RAPN (Robot Assisted Partial Nephrectomy. Materials and methods From September 2010 until December 2015, we performed 81 RAPN procedures (44 at left kidney and 37 at right. Average size was 3cm (1-9. Average PADUA score 7.1 (5-10. Average surgical time (overall and only robot time, ischemia time, blood loss, pathological stage, complications and hospital stay have been recorded. Results All of the cases were completed successfully without any operative complication or surgical conversion. Average surgical time was 177 minutes (75-340. Operative time was 145 minutes (80-300, overall blood loss was 142cc (60-310cc. In 30 cases the pedicle was late clamped with an average ischemia time of 4 minutes (2-7. None of the patient had positive surgical margins at definitive histology (49pT1a, 12pT1b, 3pT2a, 2pT3a. Hospital stay was 3 days (2-7. Conclusions The retroperitoneal robotic partial nephrectomy approach is safe and allows treatment of even quite complex tumors. It also combines the already well known advantages guaranteed by the da Vinci® robotic surgical system, with the advantages of the retroperitoneoscopic approach.

  14. Comparison of robotic and laparoscopic partial nephrectomy for small renal tumours

    Directory of Open Access Journals (Sweden)

    Abdulmuttalip Simsek

    2017-06-01

    Full Text Available Objective: To evaluate a single surgeon oncological and functional outcomes of laparoscopic partial nephrectomy (LPN compared to robotic partial nephrectomy (RPN for pT1a renal tumours. Materials and methods: Between 2006 and 2016, a retrospective review of 42 patients who underwent LPN (n = 20 or RPN (n = 22 by same surgeon was performed. Patients were matched for gender, age, body mass index (BMI, American Society of Anaesthesiologists (ASA score, tumour side, RENAL and PADUA scores, peri-operative and post-operative outcomes. Results: There was no significant differences between the two groups with respect to patient gender, age, BMI, ASA score, tumours side, RENAL and PADUA scores. Mean operative time for RPN was 176 vs. 227 minutes for LPN (p = 0.001. Warm ischemia time was similar in both groups (p = 0.58. Estimated blood loss (EBL was higher in the LPN. There was no significant difference with preoperative and postoperative creatinine and percent change in eGFR levels. Only one case in LPN had positive surgical margin. Conclusions: RPN is a developing procedure, and technically feasible and safe for small-size renal tumours. Moreover RPN is a comparable and alternative operation to LPN, providing equivalent oncological and functional outcomes, as well as saving more healthy marginal tissue and easier and faster suturing.

  15. Anatomic features involved in technical complexity of partial nephrectomy.

    Science.gov (United States)

    Hou, Weibin; Yan, Weigang; Ji, Zhigang

    2015-01-01

    Nephrometry score systems, including RENAL nephrometry, preoperative aspects and dimensions used for an anatomical classification system, C-index, diameter-axial-polar nephrometry, contact surface area score, calculating resected and ischemized volume, renal tumor invasion index, surgical approach renal ranking score, zonal NePhRO score, and renal pelvic score, have been reviewed. Moreover, salient anatomic features like the perinephric fat and vascular variants also have been discussed. We then extract 7 anatomic characteristics, namely tumor size, spatial location, adjacency, exophytic/endophytic extension, vascular variants, pelvic anatomy, and perinephric fat as important features for partial nephrectomy. For novice surgeons, comprehensive and adequate anatomic consideration may help them in their early clinical practice. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. A Mathematical Method to Calculate Tumor Contact Surface Area: An Effective Parameter to Predict Renal Function after Partial Nephrectomy.

    Science.gov (United States)

    Hsieh, Po-Fan; Wang, Yu-De; Huang, Chi-Ping; Wu, Hsi-Chin; Yang, Che-Rei; Chen, Guang-Heng; Chang, Chao-Hsiang

    2016-07-01

    We proposed a mathematical formula to calculate contact surface area between a tumor and renal parenchyma. We examined the applicability of using contact surface area to predict renal function after partial nephrectomy. We performed this retrospective study in patients who underwent partial nephrectomy between January 2012 and December 2014. Based on abdominopelvic computerized tomography or magnetic resonance imaging, we calculated the contact surface area using the formula (2*π*radius*depth) developed by integral calculus. We then evaluated the correlation between contact surface area and perioperative parameters, and compared contact surface area and R.E.N.A.L. (Radius/Exophytic/endophytic/Nearness to collecting system/Anterior/Location) score in predicting a reduction in renal function. Overall 35, 26 and 45 patients underwent partial nephrectomy with open, laparoscopic and robotic approaches, respectively. Mean ± SD contact surface area was 30.7±26.1 cm(2) and median (IQR) R.E.N.A.L. score was 7 (2.25). Spearman correlation analysis showed that contact surface area was significantly associated with estimated blood loss (p=0.04), operative time (p=0.04) and percent change in estimated glomerular filtration rate (p contact surface area and R.E.N.A.L. score independently affected percent change in estimated glomerular filtration rate (p contact surface area was a better independent predictor of a greater than 10% change in estimated glomerular filtration rate compared to R.E.N.A.L. score (AUC 0.86 vs 0.69). Using this simple mathematical method, contact surface area was associated with surgical outcomes. Compared to R.E.N.A.L. score, contact surface area was a better predictor of functional change after partial nephrectomy. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Application of modified R.E.N.A.L. nephrometry score system in evaluating the retroperitoneal partial nephrectomy for T1 renal cell carcinoma.

    Science.gov (United States)

    Wang, Qinzhang; Qian, Biao; Li, Qiang; Ni, Zhao; Li, Yinglong; Wang, Xinmin

    2015-01-01

    This study aims to investigate the application of the modified R.E.N.A.L. nephrometry score system in evaluating the operation difficulty of retroperitoneal partial nephrectomy in T1 renal cell carcinoma patients. A total of 52 patients with T1 renal cell carcinoma were enrolled. They all had retroperitoneal partial nephrectomy. Their clinical data was retrospectively analyzed. R.E.N.A.L. nephrometry score system was modified based on the features of retroperitoneal partial nephrectomy. The specificity, sensitivity and Youden index were compared between R.E.N.A.L. nephrometry score system and the modified R.E.N.A.L. nephrometry score system. The effect of the modified R.E.N.A.L. nephrometry score system on perioperative outcomes was analyzed. Three degrees of operation difficulty were defined by the modified R.E.N.A.L. nephrometry score system, which included the low, medium and high degree of operation difficulty. The specificity, sensitivity and Youden index of the modified R.E.N.A.L. nephrometry score system were better than those of the original R.E.N.A.L. nephrometry score system. Compared with low degree of operation difficulty, patients with medium and high degree of operation difficulty had significantly higher levels of operative time, warm ischemia time, and intraoperative blood loss (P system has a good effect in evaluating the operation difficulty of retroperitoneal partial nephrectomy.

  18. The financial impact of robotic technology for partial and radical nephrectomy.

    Science.gov (United States)

    Kates, Max; Ball, Mark W; Patel, Hiten D; Gorin, Michael A; Pierorazio, Phillip M; Allaf, Mohamad E

    2015-03-01

    We sought to evaluate the financial impact of robotic technology for partial nephrectomy (PN) and radical nephrectomy (RN) in the state of Maryland. The Maryland Health Services Cost Review Commission (HSCRC) documents all acute care hospital charges data. This database was queried for patients who underwent laparoscopic or robot-assisted RN and PN from 2008 to 2012. Total hospital charge, subcharge, and length of stay (LOS) were analyzed separately for RN and PN. Overall, 2834 patients were identified. Of those, 282 were laparoscopic PN (LPN), 1078 robot-assisted PN (RPN), 1098 laparoscopic RN (LRN), and 376 robot-assisted RN (RRN). For PN, the total hospital charge was $19,062 for LPN and $18,255 for RPN (P=0.138), with a charge savings of $807 per case in favor of robotics. For RN, the total hospital charge was $23,391 for RRN and $18,280 for LRN (P=0.004), with a charge premium of $5111 for robotic cases. LOS was shorter for RPN compared with LPN (2.51 vs 2.99 days, Pfinancial implications of RRN use for routine cases warrants further study.

  19. Peritumoral Artery Scoring System: a Novel Scoring System to Predict Renal Function Outcome after Laparoscopic Partial Nephrectomy.

    Science.gov (United States)

    Zhang, Ruiyun; Wu, Guangyu; Huang, Jiwei; Shi, Oumin; Kong, Wen; Chen, Yonghui; Xu, Jianrong; Xue, Wei; Zhang, Jin; Huang, Yiran

    2017-06-06

    The present study aimed to assess the impact of peritumoral artery characteristics on renal function outcome prediction using a novel Peritumoral Artery Scoring System based on computed tomography arteriography. Peritumoral artery characteristics and renal function were evaluated in 220 patients who underwent laparoscopic partial nephrectomy and then validate in 51 patients with split and total glomerular filtration rate (GFR). In particular, peritumoral artery classification and diameter were measured to assign arteries into low, moderate, and high Peritumoral Artery Scoring System risk categories. Univariable and multivariable logistic regression analyses were then used to determine risk factors for major renal functional decline. The Peritumoral Artery Scoring System and four other nephrometry systems were compared using receiver operating characteristic curve analysis. The Peritumoral Artery Scoring System was significantly superior to the other systems for predicting postoperative renal function decline (p system was a superior independent predictor of estimated glomerular filtration rate (eGFR) decline (area-under-the-curve = 0.865, p renal function outcome after laparoscopic partial nephrectomy.

  20. [Comparison of validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy].

    Science.gov (United States)

    Bi, Sheng; Xia, Ming

    2015-08-11

    To compare the validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy. A total of 28 patients were divided into two groups (holmium: YAG laser group without renal artery clamping and traditional surgery group with renal artery clamping). The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were recorded. The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were 80 ml, 77 min, 0 min, 7.4 days, 35 ml/min, 0, 0.9 cm, respectively, in holmium: YAG laser group. And in traditional surgery group were 69 ml, 111 min, 25.5 min, 7.3 days, 34 ml/min, 0, 2.0 cm, respectively. The differences of total operative time, renal artery clamping time and depth of tissue injury between two groups were statistically significant. The others were not statistically significant. Holmium: YAG laser is effective and safe in partial nephrectomy. It can decrease the total operative time, minimize the warm ischemia time and enlarge the extent of surgical excision.

  1. Do fibrin sealants impact negative outcomes after robot-assisted partial nephrectomy?

    Science.gov (United States)

    Cohen, Jason; Jayram, Gautam; Mullins, Jeffrey K; Ball, Mark W; Allaf, Mohamad E

    2013-10-01

    Contemporary rates of postoperative hemorrhage after partial nephrectomy (PN) are low. Commercially available hemostatic agents are commonly used during this surgery to reduce this risk despite a paucity of data supporting the practice. We assessed the impact of fibrin sealant hemostatic agents, a costly addition to surgeries, during robot-assisted partial nephrectomy (RAPN). Between 2007 and 2011, 114 consecutive patients underwent RAPN by a single surgeon (MEA). Evicel fibrin sealant was used in the first 74 patients during renorraphy. The last 40 patients had renorraphy performed without the use of any hemostatic agents. Clinicopathologic, operative, and complication data were compared between groups. Multivariate and univariate logistic regression analysis was performed to test the association between the use of fibrin sealants and operative outcomes. Patient demographic data and clinical tumor characteristics were similar between groups. The use of fibrin sealant did not increase operative time (166.3 vs 176.1 minutes, P=0.28), warm ischemia time (WIT) (14.4 vs 16.1 minutes, P=0.18), or length of hospital stay (2.6 vs 2.4 days, P=0.35). The omission of these agents did not increase estimated blood loss (116.6 vs 176.1 mL, P=0.8) or postoperative blood transfusion (0% vs 2.5%, P=0.17). Univariate analysis demonstrated no association between use of fibrin sealants and increased complications (P>0.05). Multivariable logistic regression showed no statistically significant predictive value of omission of hemostatic agents for perioperative outcomes (P>0.05). Perioperative hemorrhage and other major complications after contemporary RAPN are rare in experienced hands. In our study, the use of fibrin sealants during RAPN does not decrease the rate of complications, blood loss, or hospital stay. Furthermore, no impact is seen on operative time, WIT, or other negative outcomes. Omitting these agents during RAPN could be a safe, effective, cost-saving measure.

  2. Cost comparison of open and robotic partial nephrectomy using a short postoperative pathway.

    Science.gov (United States)

    Mano, Roy; Schulman, Ariel; Hakimi, A Ari; Sternberg, Itay A; Bernstein, Melanie; Bochner, Bernard H; Coleman, Jonathan A; Russo, Paul

    2015-03-01

    To compare immediate perioperative direct costs of open partial nephrectomy (OPN) and robotic partial nephrectomy (RPN), managed under a common care pathway. Retrospective review of detailed institutional cost data for patients treated with OPN and RPN during 2011 was conducted. Cost and clinical data of OPN and RPN were compared for all patients and for patients stratified by length of stay (LOS), American Society of Anesthesiologists (ASA), and RENAL nephrometry scores. The study cohort included 190 OPN and 63 RPN cases. OPN was associated with higher ASA scores (P days (2-3 days) for OPN compared with 1 day (1-2 days) for RPN (P cost of OPN was lower than that of RPN with a difference of $3091 (P costs were higher in OPN, surgical costs were higher in RPN ($854 and $3695 difference in median costs, respectively; P cost of OPN for patients with an above-average LOS remained lower than that of RPN ($2680 difference in median costs; P = .001). RPN costs remained significantly higher when stratifying patients by their ASA and RENAL nephrometry scores. Despite the shorter hospital LOS associated with RPN, the immediate perioperative cost of OPN was lower than that of RPN for patients managed under a common care pathway, mainly due to high robotic purchase and maintenance costs. In light of the current health care debate, such financial disincentives may compromise the sustainability of advances in medical technology. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Urine leak in minimally invasive partial nephrectomy: analysis of risk factors and role of intraoperative ureteral catheterization

    Directory of Open Access Journals (Sweden)

    Homayoun Zargar

    2014-12-01

    Full Text Available Purpose To investigate risk factors for urine leak in patients undergoing minimally invasive partial nephrectomy (MIPN and to determine the role of intraoperative ureteral catheterization in preventing this postoperative complication. Materials and Methods MIPN procedures done from September 1999 to July 2012 at our Center were reviewed from our IRB-approved database. Patient and tumor characteristics, operative techniques and outcomes were analyzed. Patients with evidence of urine leak were identified. Outcomes were compared between patients with preoperative ureteral catheterization (C-group and those without (NC-group. Univariable and multivariable analyses were performed to identify factors predicting postoperative urine leak. Results A total of 1,019 cases were included (452 robotic partial nephrectomy cases and 567 laparoscopic partial nephrectomy cases. Five hundred twenty eight patients (51.8% were in the C-group, whereas 491 of them (48.2% in the NC-group. Urine leak occurred in 31(3% cases, 4.6% in the C-group and 1.4% in the NC-group (p<0.001. Tumors in NC-group had significantly higher RENAL score, shorter operative and warm ischemic times. On multivariable analysis, tumor proximity to collecting system (OR=9.2; p<0.01, surgeon’s early operative experience (OR=7.8; p<0.01 and preoperative moderate to severe CKD (OR=3.1; p<0.01 significantly increased the odds of the occurrence of a postoperative urine leak. Conclusion Clinically significant urine leak after MIPN in a high volume institution setting is uncommon. This event is more likely to occur in cases of renal masses that are close to the collecting system, in patients with preoperative CKD and when operating surgeon is still in the learning curve for the procedure. Our findings suggest that routine intraoperative ureteral catheterization during MIPN does not reduce the probability of postoperative urine leak. In addition, it adds to the overall operative time.

  4. Multiple Renal Artery Pseudoaneurysms in Patients Undergoing Renal Artery Embolization Following Partial Nephrectomy: Correlation with RENAL Nephrometry Scores

    International Nuclear Information System (INIS)

    Gupta, Nakul; Patel, Anish; Ensor, Joe; Ahrar, Kamran; Ahrar, Judy; Tam, Alda; Odisio, Bruno; Huang, Stephen; Murthy, Ravi; Mahvash, Armeen; Avritscher, Rony; McRae, Stephen; Sabir, Sharjeel; Wallace, Michael; Matin, Surena; Gupta, Sanjay

    2017-01-01

    PurposeTo describe the incidence of multiple renal artery pseudoaneurysms (PSA) in patients referred for renal artery embolization following partial nephrectomy and to study its relationship to RENAL nephrometry scores.Materials and MethodsThe medical records of 25 patients referred for renal artery embolization after partial nephrectomy were retrospectively reviewed for the following parameters: size and number of tumors, RENAL nephrometry scores, angiographic abnormalities, technical and clinical outcomes, and estimated glomerular filtration rates (eGFRs) after embolization.ResultsTwenty-four patients had primary renal tumors, while 1 patient had a pancreatic tumor invading the kidney. Multiple tumors were resected in 4 patients. Most patients (92 %) were symptomatic, presenting with gross hematuria, flank pain, or both. Angiography revealed PSA with (n = 5) or without (n = 20) AV fistulae. Sixteen patients (64 %) had multiple PSA involving multiple renal vessels. Higher RENAL nephrometry scores were associated with an increasing likelihood of multiple PSA. Multiple vessels were embolized in 14 patients (56 %). Clinical success was achieved after one (n = 22) or two (n = 3) embolization sessions in all patients. Post-embolization eGFR values at different time points after embolization were not significantly different from the post-operative eGFR.ConclusionA majority of patients requiring renal artery embolization following partial nephrectomy have multiple pseudoaneurysms, often requiring selective embolization of multiple vessels. Higher RENAL nephrometry score is associated with an increasing likelihood of multiple pseudoaneurysms. We found transarterial embolization to be a safe and effective treatment option with no long-term adverse effect on renal function in all but one patient with a solitary kidney.

  5. Multiple Renal Artery Pseudoaneurysms in Patients Undergoing Renal Artery Embolization Following Partial Nephrectomy: Correlation with RENAL Nephrometry Scores

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Nakul [Houston Methodist Hospital (United States); Patel, Anish [The University of Texas Southwestern Medical Center (United States); Ensor, Joe [Houston Methodist Research Institute, The Houston Methodist Cancer Center (United States); Ahrar, Kamran; Ahrar, Judy; Tam, Alda; Odisio, Bruno; Huang, Stephen; Murthy, Ravi; Mahvash, Armeen; Avritscher, Rony; McRae, Stephen; Sabir, Sharjeel; Wallace, Michael [The University of Texas MD Anderson Cancer Center, Department of Interventional Radiology (United States); Matin, Surena [The University of Texas MD Anderson Cancer Center, Department of Urology (United States); Gupta, Sanjay, E-mail: sgupta@mdanderson.org [The University of Texas MD Anderson Cancer Center, Department of Interventional Radiology (United States)

    2017-02-15

    PurposeTo describe the incidence of multiple renal artery pseudoaneurysms (PSA) in patients referred for renal artery embolization following partial nephrectomy and to study its relationship to RENAL nephrometry scores.Materials and MethodsThe medical records of 25 patients referred for renal artery embolization after partial nephrectomy were retrospectively reviewed for the following parameters: size and number of tumors, RENAL nephrometry scores, angiographic abnormalities, technical and clinical outcomes, and estimated glomerular filtration rates (eGFRs) after embolization.ResultsTwenty-four patients had primary renal tumors, while 1 patient had a pancreatic tumor invading the kidney. Multiple tumors were resected in 4 patients. Most patients (92 %) were symptomatic, presenting with gross hematuria, flank pain, or both. Angiography revealed PSA with (n = 5) or without (n = 20) AV fistulae. Sixteen patients (64 %) had multiple PSA involving multiple renal vessels. Higher RENAL nephrometry scores were associated with an increasing likelihood of multiple PSA. Multiple vessels were embolized in 14 patients (56 %). Clinical success was achieved after one (n = 22) or two (n = 3) embolization sessions in all patients. Post-embolization eGFR values at different time points after embolization were not significantly different from the post-operative eGFR.ConclusionA majority of patients requiring renal artery embolization following partial nephrectomy have multiple pseudoaneurysms, often requiring selective embolization of multiple vessels. Higher RENAL nephrometry score is associated with an increasing likelihood of multiple pseudoaneurysms. We found transarterial embolization to be a safe and effective treatment option with no long-term adverse effect on renal function in all but one patient with a solitary kidney.

  6. Hilar Parenchymal Oversew: a novel technique for robotic partial nephrectomy hilar tumor renorrhaphy.

    Science.gov (United States)

    Chavali, Jaya Sai S; Nelson, Ryan; Maurice, Matthew J; Kara, Onder; Mouracade, Pascal; Dagenais, Julien; Reese, Jeremy; Bayona, Pilar; Haber, Georges-Pascal; Stein, Robert J

    2018-01-01

    A renorrhaphy technique which is effective for hemostasis but does not place undue tension on the branch vessels of the renal sinus remains one of the challenging steps after hilar tumor resection during robotic partial nephrectomy (RPN). The published V-hilar suture (VHS) technique is one option for reconstruction after an RPN involving the hilum. The objective of this video is to show a novel renorrhaphy technique, Hilar Parenchymal Oversew that has been effective for such cases. We present two cases of RPN for renal hilar tumors. The first case depicts use of the VHS renorrhaphy technique for a tumor that abuts the renal hilum along 20% of its diameter. The second case demonstrates tumor resection and reconstruction for a tumor that has >50% involvement of the hilum along its diameter. After tumor resection, individual sinus vessels can be selectively oversewn with 2-0 Vicryl suture on SH needle. The remaining exposed parenchyma is controlled using the Hilar Parenchymal Oversew technique with a #0 Vicryl on CT-1 needle. For the Hilar Parenchymal Oversew surgery operative time was 225 min, estimated blood loss was 140 ml, warm ischemia time was 19 minutes, and there were no intraoperative complications. Pathology was consistent with clear cell renal cancer with negative margins. Robotic partial nephrectomy with the Hilar Parenchymal Oversew technique is a good alternative to VHS renorrhaphy in the management of renal hilar tumors "bulging" into the renal sinus with >50% of the tumor diameter abutting the hilum. Copyright® by the International Brazilian Journal of Urology.

  7. Partial nephrectomy online: a preliminary evaluation of the quality of health information on the Internet.

    Science.gov (United States)

    Fast, Angela M; Deibert, Christopher M; Boyer, Celia; Hruby, Gregory W; McKiernan, James M

    2012-12-01

    What's known on the subject? and What does the study add? Patients are highly likely to access the Internet for health information, and studies have reported that inaccurate or low-quality information may alter patients' expectations and negatively impact informed decision-making. In a unique collaboration with the Health On the Internet (HON) Foundation, we evaluated the top 20 search results for the urology search term 'partial nephrectomy,' and identified the highest and lowest scoring criteria to increase awareness of areas of concern and improvement. To further evaluate the quality of information available on the Internet with regard to the management of localized renal cancer, we evaluated websites providing information on 'partial nephrectomy' in conjunction with the Health On the Internet (HON) Foundation. Many patients now utilize the Internet as a resource to provide further information on disease, treatments and outcomes, and health information on the Internet is largely unregulated. Inaccurate information may contribute to unrealistic expectations and dissatisfied patients. A google.com search identified the top 30 websites for the search term 'partial nephrectomy'. The HON Foundation evaluated each website according to the eight principles for Health on the Internet code of conduct (HONcode) certification and reported the overall frequency of certification, as well as individual website compliance with each of the principles. Overall, seven (23.3%) of 30 websites met the requirements of HONcode certification and an additional two (6.7%) websites were under review to maintain their certification based on updating their resources. The remaining 21 (70%) websites did not meet the standards for certification. The lowest performing criteria included proper citation of medical information and a clear distinction of advertising from editorial content. The low rate of HONcode compliance for these websites illustrates the poor quality of information that

  8. Retroperitoneal Laparoscopic Partial Nephrectomy Versus Radical Nephrectomy for Clinical T1 Renal Hilar Tumor: Comparison of Perioperative Characteristics and Short-Term Functional and Oncologic Outcomes.

    Science.gov (United States)

    Yang, Chuance; Wang, Zhenlong; Huang, Shanlong; Xue, Li; Fu, Delai; Chong, Tie

    2018-04-18

    To present our single-center experience with retroperitoneal laparoscopic partial nephrectomy (LPN) and retroperitoneal laparoscopic radical nephrectomy (LRN) for T1 renal hilar tumors and evaluate which one is better. A retrospective review of 63 patients with hilar tumors undergoing retroperitoneal LPN or LRN was performed. The perioperative characteristics, change in estimated glomerular filtration rate (eGFR) from baseline to month 3, and oncologic outcomes were summarized. In total, 25 patients underwent LPN, and 38 patients underwent LRN. The mean tumor size in the LPN and LRN groups was 4.5 and 4.9 cm, respectively. The mean operation time was longer in the LPN group than that in the LRN group (212.5 minutes versus 160.7 minutes, respectively; P  .05). In experienced hands, although retroperitoneal LRN can result in shorter operation times and shorter lengths of stay, retroperitoneal LPN can preserve renal function better than LRN. Retroperitoneal LPN should be the priority in selected patients with T1 renal hilar tumors, especially for patients with renal insufficiency.

  9. Impact of Renal Hilar Control on Outcomes of Robotic Partial Nephrectomy: Systematic Review and Cumulative Meta-analysis.

    Science.gov (United States)

    Cacciamani, Giovanni E; Medina, Luis G; Gill, Tania S; Mendelsohn, Alec; Husain, Fatima; Bhardwaj, Lokesh; Artibani, Walter; Sotelo, Renè; Gill, Inderbir S

    2018-02-05

    During robotic partial nephrectomy (RPN), various techniques of hilar control have been described, including on-clamp, early unclamping, selective/super-selective clamping, and completely-unclamped RPN. To evaluate the impact of various hilar control techniques on perioperative, functional, and oncological outcomes of RPN for tumors. We conducted a systematic literature review and meta-analysis of all comparative studies on various hilar control techniques during RPN using PubMed, Scopus, and Web of Science according to the Preferred Reporting Items for Systematic Review and Meta-analysis statement, and Methods and Guide for Effectiveness and Comparative Effectiveness Review of the Agency for Healthcare Research and Quality. Cumulative meta-analysis of comparative studies was conducted using Review Manager 5.3. Of 987 RPN publications in the literature, 19 qualified for this analysis. Comparison of off-clamp versus on-clamp RPN (n=9), selective clamping versus on-clamp RPN (n=3), super selective clamping versus on-clamp RPN (n=5), and early unclamped versus on-clamp (n=3) were reported. Patients undergoing RPN using off-clamp, selective/super selective, or early unclamp techniques had higher estimated blood loss compared with on-clamp RPN (weight mean difference [WMD]: 47.83, p=0.000, WMD: 41.06, p=0.02, and WMD: 37.50, p=0.47); however, this did not seem clinically relevant, since transfusion rates were similar (odds ratio [OR]: 0.98, p=0.95, OR: 0.72, p=0.7, and OR: 1.36, p=0.33, respectively). All groups appeared similar with regards to hospital stay, transfusions, overall and major complications, and positive cancer margin rates. Short- and long-term renal functional outcomes appeared superior in the off-clamp and super selective clamp groups compared with the on-clamp RPN cohort. Off-clamp, selective/super selective clamp, and early unclamp hilar control techniques are safe and feasible approaches for RPN surgery, with similar perioperative and oncological

  10. Laparo-Endoscopic Single-Site Surgery for Radical and Cytoreductive Nephrectomy, Renal Vein Thrombectomy, and Partial Nephrectomy: A Prospective Pilot Evaluation

    Directory of Open Access Journals (Sweden)

    Ithaar H. Derweesh

    2010-01-01

    Full Text Available Introduction. Laparo-endoscopic single-site surgery (LESS may diminish morbidity of laparoscopic surgery. We prospectively evaluated feasibility and outcomes of LESS-Radical Nephrectomy (LESS-RN and Partial Nephrectomy (LESS-PN. Methods. 10 patients underwent LESS-RN (6 and LESS-PN (4 between 2/2009-5/2009. LESS-RN included 2 with renal vein thrombectomy, one of which was also cytoreductive. Transperitoneal LESS access was obtained by periumbilical incision. Patient/tumor characteristics, oncologic, and quality of life (QoL outcomes were analyzed. Results. 3 Men/7 Women (mean age 58.7 years, median follow-up 9.8 months underwent LESS. 9/10 cases were completed successfully. All had negative margins. Mean operative time was 161 minutes, estimated blood loss was 125 mL, and incision size was 4.4 cm. Median tumor size for LESS-RN and -PN was 5.0 and 1.7 cm (=.045. Median LESS-PN ischemia time was 24 minutes; mean preoperative/postoperative creatinine were 0.7/0.8 mg/dL (=.19. Mean pain score at discharge was 1.3. Mean preoperative, 3-, and 6-month postoperative SF-36 QoL Score was 73.8, 74.4 and 77.1 (=.222. All patients are currently alive. Conclusions. LESS-RN, renal vein thrombectomy, and PN are technically feasible and safe while maintaining adherence to oncologic principles, with excellent QoL preservation and low discharge pain scores. Further study is requisite.

  11. Fast Track Open Partial Nephrectomy: Reduced Postoperative Length of Stay with a Goal-Directed Pathway Does Not Compromise Outcome

    Directory of Open Access Journals (Sweden)

    Bilal Chughtai

    2008-01-01

    Full Text Available Introduction. The aim of this study is to examine the feasibility of reducing postoperative hospital stay following open partial nephrectomy through the implementation of a goal directed clinical management pathway. Materials and Methods. A fast track clinical pathway for open partial nephrectomy was introduced in July 2006 at our institution. The pathway has daily goals and targets discharge for all patients on the 3rd postoperative day (POD. Defined goals are (1 ambulation and liquid diet on the evening of the operative day; (2 out of bed (OOB at least 4 times on POD 1; (3 removal of Foley catheter on the morning of POD 2; (4 removal of Jackson Pratt drain on the afternoon of POD 2; (4 discharge to home on POD 3. Patients and family are instructed in the fast track protocol preoperatively. Demographic data, tumor size, length of stay, and complications were captured in a prospective database, and compared to a control group managed consecutively immediately preceding the institution of the fast track clinical pathway. Results. Data on 33 consecutive patients managed on the fast track clinical pathway was compared to that of 25 control patients. Twenty two (61% out of 36 fast track patients and 4 (16% out of 25 control patients achieved discharge on POD 3. Overall, fast track patients had a shorter hospital stay than controls (median, 3 versus 4 days; P = .012. Age (median, 55 versus 57 years, tumor size (median, 2.5 versus 2.5 cm, readmission within 30 days (5.5% versus 5.1%, and complications (10.2% versus 13.8% were similar in the fast track patients and control, respectively. Conclusions. In the present series, a fast track clinical pathway after open partial nephrectomy reduced the postoperative length of hospital stay and did not appear to increase the postoperative complication rate.

  12. Targeted Endovascular Temporary Vessel Occlusion with a Reverse Thermosensitive Polymer for Near-Bloodless Partial Nephrectomy: Comparison to Standard Surgical Clamping Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Flacke, Sebastian, E-mail: Sebastian.Flacke@lahey.org [Lahey Clinic, Tuft University Medical School, Department of Radiology (United States); Harty, Niall J.; Laskey, Daniel H.; Moinzadeh, Alireza [Lahey Clinic, Tuft University Medical School, Department of Urology (United States); Benn, James A. [Pluromed Inc (United States); Villani, Rosanna [DaVinci Biomedical Research Products (United States); Kalra, Aarti [Lahey Clinic, Tuft University Medical School, Department of Pathology (United States); Libertino, John A.; Madras, Peter N. [Lahey Clinic, Tuft University Medical School, Department of Urology (United States)

    2012-10-15

    Purpose: To determine whether reversible blood flow interruption to a randomly chosen target region of the kidney may be achieved with the injection of a reverse thermoplastic polymer through an angiographic catheter, thereby facilitating partial nephrectomy without compromising blood flow to the remaining kidney or adding risks beyond those encountered by the use of hilar clamping. Methods: Fifteen pigs underwent partial nephrectomy after blood flow interruption by vascular cross-clamping or injection of polymer (Lumagel Trade-Mark-Sign ) into a segmental artery. Five animals were euthanized after surgery (three open and two laparoscopic resection, cross-clamping n = 2), and 10 (open resection, cross-clamping n = 4) were euthanized after 6 weeks' survival. Blood specimens were obtained periodically, and angiogram and necropsy were performed at 6 weeks. Results: Selective renal ischemia was achieved in all cases. Surgical resection time averaged 9 and 24.5 min in the open and laparoscopic groups, respectively. Estimated blood loss was negligible with the exception of one case where an accessory renal artery was originally overlooked. Reversal of the polymer to a liquid state was consistent angiographically and visually in all cases. Time to complete flow return averaged 7.4 and 2 min for polymer and clamping, respectively. Angiography at 6 weeks revealed no evidence of vascular injury. Laboratory data and necropsies revealed no differences between animals undergoing vascular clamping or polymer injection. Conclusion: Lumagel was as effective as vascular clamping in producing a near bloodless operative field for partial nephrectomy while maintaining flow to the uninvolved portion of the affected kidney.

  13. Clinical application of calculated split renal volume using computed tomography-based renal volumetry after partial nephrectomy: Correlation with technetium-99m dimercaptosuccinic acid renal scan data.

    Science.gov (United States)

    Lee, Chan Ho; Park, Young Joo; Ku, Ja Yoon; Ha, Hong Koo

    2017-06-01

    To evaluate the clinical application of computed tomography-based measurement of renal cortical volume and split renal volume as a single tool to assess the anatomy and renal function in patients with renal tumors before and after partial nephrectomy, and to compare the findings with technetium-99m dimercaptosuccinic acid renal scan. The data of 51 patients with a unilateral renal tumor managed by partial nephrectomy were retrospectively analyzed. The renal cortical volume of tumor-bearing and contralateral kidneys was measured using ImageJ software. Split estimated glomerular filtration rate and split renal volume calculated using this renal cortical volume were compared with the split renal function measured with technetium-99m dimercaptosuccinic acid renal scan. A strong correlation between split renal function and split renal volume of the tumor-bearing kidney was observed before and after surgery (r = 0.89, P volumetry had a strong correlation with the split renal function measured using technetium-99m dimercaptosuccinic acid renal scan. Computed tomography-based split renal volume measurement before and after partial nephrectomy can be used as a single modality for anatomical and functional assessment of the tumor-bearing kidney. © 2017 The Japanese Urological Association.

  14. Commentary on "a matched comparison of perioperative outcomes of a single laparoscopic surgeon versus a multisurgeon robot-assisted cohort for partial nephrectomy." Ellison JS, Montgomery JS, Wolf Jr JS, Hafez KS, Miller DC, Weizer AZ, Department of Urology, University of Michigan, Ann Arbor, MI, USA: J Urol 2012;188(1):45-50.

    Science.gov (United States)

    Kane, Christopher

    2013-02-01

    Minimally invasive nephron sparing surgery is gaining popularity for small renal masses. Few groups have evaluated robot-assisted partial nephrectomy compared to other approaches using comparable patient populations. We present a matched pair analysis of a heterogeneous group of surgeons who performed robot-assisted partial nephrectomy and a single experienced laparoscopic surgeon who performed conventional laparoscopic partial nephrectomy. Perioperative outcomes and complications were compared. All 249 conventional laparoscopic and robot-assisted partial nephrectomy cases from January 2007 to June 2010 were reviewed from our prospectively maintained institutional database. Groups were matched 1:1 (108 matched pairs) by R.E.N.A.L. (radius, exophytic/endophytic properties, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines) nephrometry score, transperitoneal vs retroperitoneal approach, patient age and hilar nature of the tumor. Statistical analysis was done to compare operative outcomes and complications. Matched analysis revealed that nephrometry score, age, gender, tumor side and American Society of Anesthesia physical status classification were similar. Operative time favored conventional laparoscopic partial nephrectomy. During the study period robot-assisted partial nephrectomy showed significant improvements in estimated blood loss and warm ischemia time compared to those of the experienced conventional laparoscopic group. Postoperative complication rates, and complication distributions by Clavien classification and type were similar for conventional laparoscopic and robot-assisted partial nephrectomy (41.7% and 35.0%, respectively). Robot-assisted partial nephrectomy has a noticeable but rapid learning curve. After it is overcome the robotic procedure results in perioperative outcomes similar to those achieved with conventional laparoscopic partial nephrectomy done by an experienced surgeon. Robot

  15. Review of laparoscopic partial nephrectomy in the treatment of renal tumors, T1 stadium in adults; Revision de la nefrectomia parcial laparoscopica en el tratamiento de los tumores renales, estadio T1 en adultos

    Energy Technology Data Exchange (ETDEWEB)

    Zamora Montes de Oca, Maria Jose

    2012-07-01

    The T1 renal cancer in adults is made known; incidence, characteristics and management. Renal cell carcinoma has been the most common malignancy of the kidney, percentage is close to three percent of solid tumors of adults. The treatments for this tumor are analyzed: open radical nephrectomy, laparoscopic radical nephrectomy, open partial nephrectomy and laparoscopic partial nephrectomy. Laparoscopic partial nephrectomy has represented an alternative option acceptable, safely and with good oncological and surgical outcomes for patients, as it is used to conserve nephrons and simultaneously to resect the tumor of a complete form promoting in the future the patient present a good renal function. Additionally, a adequate oncological control has reduced the risk of submit postoperative renal failure. An evolution of laparoscopic partial nephrectomy is presented determining the procedure for renal tumors in state T1 in the adults [Spanish] El cancer renal T1 en adultos es dado a conocer; su incidencia, caracteristicas y manejo. El carcinoma de celulas renales ha sido la malignidad mas comun de los rinones, su porcentaje se acerca al tres porciento de los tumores solidos de los adultos. Los tratamientos para combatir ese tumor son analizados: nefrectomia radical abierta, nefrectomia radical laparoscopica, nefrectomia parcial abierta y nefrectomia parcial laparoscopica. La nefrectonomia parcial laparoscopica ha representado una opcion alternativa aceptable, segura y con buenos resultados oncologicos y quirurgicos para los pacientes, ya que es utilizada para conservar nefronas y a la vez poder resecar el tumor de una forma completa promoviendo en el futuro que el paciente presente un buen funcionamiento renal. Ademas, un adecuado control oncologico ha reducido el riesgo de presentar insuficiencia renal postoperatoria. Una evolucion de la nefrectonomia parcial laparoscopica es presentada determinando el procedimiento para tumores renales en estado T1 en los adultos.

  16. Augmented reality during robot-assisted laparoscopic partial nephrectomy: toward real-time 3D-CT to stereoscopic video registration.

    Science.gov (United States)

    Su, Li-Ming; Vagvolgyi, Balazs P; Agarwal, Rahul; Reiley, Carol E; Taylor, Russell H; Hager, Gregory D

    2009-04-01

    To investigate a markerless tracking system for real-time stereo-endoscopic visualization of preoperative computed tomographic imaging as an augmented display during robot-assisted laparoscopic partial nephrectomy. Stereoscopic video segments of a patient undergoing robot-assisted laparoscopic partial nephrectomy for tumor and another for a partial staghorn renal calculus were processed to evaluate the performance of a three-dimensional (3D)-to-3D registration algorithm. After both cases, we registered a segment of the video recording to the corresponding preoperative 3D-computed tomography image. After calibrating the camera and overlay, 3D-to-3D registration was created between the model and the surgical recording using a modified iterative closest point technique. Image-based tracking technology tracked selected fixed points on the kidney surface to augment the image-to-model registration. Our investigation has demonstrated that we can identify and track the kidney surface in real time when applied to intraoperative video recordings and overlay the 3D models of the kidney, tumor (or stone), and collecting system semitransparently. Using a basic computer research platform, we achieved an update rate of 10 Hz and an overlay latency of 4 frames. The accuracy of the 3D registration was 1 mm. Augmented reality overlay of reconstructed 3D-computed tomography images onto real-time stereo video footage is possible using iterative closest point and image-based surface tracking technology that does not use external navigation tracking systems or preplaced surface markers. Additional studies are needed to assess the precision and to achieve fully automated registration and display for intraoperative use.

  17. Robotic retroperitoneal partial nephrectomy: a step-by-step guide.

    Science.gov (United States)

    Ghani, Khurshid R; Porter, James; Menon, Mani; Rogers, Craig

    2014-08-01

    To describe a step-by-step guide for successful implementation of the retroperitoneal approach to robotic partial nephrectomy (RPN) PATIENTS AND METHODS: The patient is placed in the flank position and the table fully flexed to increase the space between the 12th rib and iliac crest. Access to the retroperitoneal space is obtained using a balloon-dilating device. Ports include a 12-mm camera port, two 8-mm robotic ports and a 12-mm assistant port placed in the anterior axillary line cephalad to the anterior superior iliac spine, and 7-8 cm caudal to the ipsilateral robotic port. Positioning and port placement strategies for successful technique include: (i) Docking robot directly over the patient's head parallel to the spine; (ii) incision for camera port ≈1.9 cm (1 fingerbreadth) above the iliac crest, lateral to the triangle of Petit; (iii) Seldinger technique insertion of kidney-shaped balloon dilator into retroperitoneal space; (iv) Maximising distance between all ports; (v) Ensuring camera arm is placed in the outer part of the 'sweet spot'. The retroperitoneal approach to RPN permits direct access to the renal hilum, no need for bowel mobilisation and excellent visualisation of posteriorly located tumours. © 2014 The Authors. BJU International © 2014 BJU International.

  18. The Role of Indocyanine Green for Robotic Partial Nephrectomy: Early Results, Limitations and Future Directions

    Directory of Open Access Journals (Sweden)

    Zachary Klaassen

    2014-07-01

    Full Text Available The surgical management of small renal masses has continued to evolve, particularly with the advent of the robotic partial nephrectomy (RPN. Recent studies at high volume institutions utilizing near infrared imaging with indocyanine green (ICG fluorescent dye to delineate renal tumor anatomy has generated interest among robotic surgeons for improving warm ischemia times and positive margin rate for RPN. To date, early studies suggest positive margin rate using ICG is comparable to traditional RPN, however this technology improves visualization of the renal vasculature allowing selective clamping or zero ischemia. The precise combination of fluorescent compound, dose, and optimal tumor anatomy for ICG RPN has yet to be elucidated.

  19. Application and analysis of retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping for patients with multiple renal tumor: initial experience.

    Science.gov (United States)

    Zhu, Jundong; Jiang, Fan; Li, Pu; Shao, Pengfei; Liang, Chao; Xu, Aiming; Miao, Chenkui; Qin, Chao; Wang, Zengjun; Yin, Changjun

    2017-09-11

    To explore the feasibility and safety of retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping for the patients with multiple renal tumor of who have solitary kidney or contralateral kidney insufficiency. Nine patients who have undergone retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping between October 2010 and January 2017 were retrospectively analyzed. Clinical materials and parameters during and after the operation were summarized. Nineteen tumors were resected in nine patients and the operations were all successful. The operation time ranged from 100 to 180 min (125 min); clamping time of segmental renal artery was 10 ~ 30 min (23 min); the amount of blood loss during the operation was 120 ~ 330 ml (190 ml); hospital stay after the operation is 3 ~ 6d (5d). There was no complication during the perioperative period, and the pathology diagnosis after the surgery showed that there were 13 renal clear cell carcinomas, two papillary carcinoma and four perivascular epithelioid cell tumors with negative margins from the 19 tumors. All patients were followed up for 3 ~ 60 months, and no local recurrence or metastasis was detected. At 3-month post-operation follow-up, the mean serum creatinine was 148.6 ± 28.1 μmol/L (p = 0.107), an increase of 3.0 μmol/L from preoperative baseline. For the patients with multiple renal tumors and solitary kidney or contralateral kidney insufficiency, retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping was feasible and safe, which minimized the warm ischemia injury to the kidney and preserved the renal function effectively.

  20. A multimodal imaging framework for enhanced robot-assisted partial nephrectomy guidance

    Science.gov (United States)

    Halter, Ryan J.; Wu, Xiaotian; Hartov, Alex; Seigne, John; Khan, Shadab

    2015-03-01

    Robot-assisted laparoscopic partial nephrectomies (RALPN) are performed to treat patients with locally confined renal carcinoma. There are well-documented benefits to performing partial (opposed to radical) kidney resections and to using robot-assisted laparoscopic (opposed to open) approaches. However, there are challenges in identifying tumor margins and critical benign structures including blood vessels and collecting systems during current RALPN procedures. The primary objective of this effort is to couple multiple image and data streams together to augment visual information currently provided to surgeons performing RALPN and ultimately ensure complete tumor resection and minimal damage to functional structures (i.e. renal vasculature and collecting systems). To meet this challenge we have developed a framework and performed initial feasibility experiments to couple pre-operative high-resolution anatomic images with intraoperative MRI, ultrasound (US) and optical-based surface mapping and kidney tracking. With these registered images and data streams, we aim to overlay the high-resolution contrast-enhanced anatomic (CT or MR) images onto the surgeon's view screen for enhanced guidance. To date we have integrated the following components of our framework: 1) a method for tracking an intraoperative US probe to extract the kidney surface and a set of embedded kidney markers, 2) a method for co-registering intraoperative US scans with pre-operative MR scans, and 3) a method for deforming pre-op scans to match intraoperative scans. These components have been evaluated through phantom studies to demonstrate protocol feasibility.

  1. Robot-assisted partial nephrectomy for hilar tumors: perioperative outcomes.

    Science.gov (United States)

    Eyraud, Rémi; Long, Jean-Alexandre; Snow-Lisy, Devon; Autorino, Riccardo; Hillyer, Shahab; Klink, Joseph; Rizkala, Emad; Stein, Robert J; Kaouk, Jihad H; Haber, Georges-Pascal

    2013-06-01

    To compare perioperative outcomes of robot-assisted partial nephrectomy (RAPN) for hilar vs nonhilar tumors. The study retrospectively reviewed 364 patients with available computed tomography scans undergoing RAPN. Demographic data and perioperative outcomes results were compared between the hilar (group 1, n = 70) and nonhilar tumors (group 2, n = 294). Multivariate analysis was used to identify predictors of warm ischemia time (WIT), estimated blood loss (EBL), major perioperative complications, and postoperative renal function. There were no differences with respect to demographic variables. Hilar tumors had higher RENAL (radius, exophytic/endophytic properties of the tumor, nearness of tumor deepest portion to the collecting system or sinus, anterior/posterior descriptor and the location relative to polar lines) scores (P hilar tumors were associated with greater operative time (210 vs 180 minutes, P hilar vs nonhilar patients on postoperative day 3 (70.12 vs 74.71 mL/min/1.73 m(2), P = .31) or at last follow-up (72.62 vs 75.78 mL/min/1.73 m(2), P = .40), respectively. Multivariate analysis found hilar location was independently associated with increased WIT without significant changes in EBL, major complications, or postoperative renal function. RAPN represents a safe and effective procedure for hilar tumors. Hilar location for patients undergoing RAPN in a high-volume institution seems not be associated with an increased risk of transfusions, major complications, or decline of early postoperative renal function. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Comparing renal function preservation after laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy for clinical T1a renal tumor: using a 3D parenchyma measurement system.

    Science.gov (United States)

    Zhu, Liangsong; Wu, Guangyu; Huang, Jiwei; Wang, Jianfeng; Zhang, Ruiyun; Kong, Wen; Xue, Wei; Huang, Yiran; Chen, Yonghui; Zhang, Jin

    2017-05-01

    To compare the renal function preservation between laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy. Data were analyzed from 246 patients who underwent laparoscopic radio frequency ablation assisted tumor enucleation and laparoscopic partial nephrectomy for solitary cT1a renal cell carcinoma from January 2013 to July 2015. To reduce the intergroup difference, we used a 1:1 propensity matching analysis. The functional renal parenchyma volume preservation were measured preoperative and 12 months after surgery. The total renal function recovery and spilt GFR was compared. Multivariable logistic analysis was used for predictive factors for renal function decline. After 1:1 propensity matching, each group including 100 patients. Patients in the laparoscopic radio frequency ablation assisted tumor enucleation had a smaller decrease in estimate glomerular filtration rate at 1 day (-7.88 vs -20.01%, p renal parenchyma volume preservation (89.19 vs 84.27%, p renal parenchyma volume preservation, warm ischemia time and baseline renal function were the important independent factors in determining long-term functional recovery. The laparoscopic radio frequency ablation assisted tumor enucleation technology has unique advantage and potential in preserving renal parenchyma without ischemia damage compared to conventional laparoscopic partial nephrectomy, and had a better outcome, thus we recommend this technique in selected T1a patients.

  3. Multi-institutional analysis of robotic partial nephrectomy for hilar versus nonhilar lesions in 446 consecutive cases.

    Science.gov (United States)

    Dulabon, Lori M; Kaouk, Jihad H; Haber, Georges-Pascal; Berkman, Douglas S; Rogers, Craig G; Petros, Firas; Bhayani, Sam B; Stifelman, Michael D

    2011-03-01

    Minimally invasive approaches to partial nephrectomy have been rapidly gaining popularity but require advanced laparoscopic surgical skills. Renal hilar tumors, due to their anatomic location, pose additional technical challenges to the operating surgeon. We compared the outcomes of robot-assisted partial nephrectomy (RPN) for hilar and nonhilar tumors in our large multicenter contemporary series of patients. We retrospectively reviewed prospectively collected data on 446 consecutive patients who underwent RPN by renal surgeons experienced in minimally invasive techniques at four academic institutions from June 2006 to March 2010. Patients were stratified into two groups: those with hilar lesions and those with nonhilar lesions. Patient demographics, operative outcomes, and postoperative outcomes, including oncologic outcomes, were recorded. Forty-one patients (9%) had hilar renal masses; 405 patients (91%) had nonhilar masses. There was no statistical differences in patient demographics except for larger median tumor size in the hilar cohort (3.2 cm vs 2.6 cm; p=0.001). The only significant difference in operative outcomes was an increase in warm ischemia times for the hilar group versus the nonhilar group (26.3±7.4 min vs 19.6±10.0 min; p=<0.0001). There were no differences in postoperative outcomes; however, there was a trend for increased risk of malignancy and higher stage tumors in the hilar lesion group. Final pathologic margin status was similar in both groups. Only one patient in the nonhilar group had evidence of recurrence at 21 mo. The study was limited by the lack of standard anatomic classification of renal tumors and the potential influence of the surgeons' prior robotic experience. The data represent the largest series of its kind and strongly suggest that RPN is a safe, effective, and feasible option for the minimally invasive approach to renal hilar tumors with no increased risk of adverse outcomes compared with nonhilar tumors in the hands of

  4. Who is at risk of death from nephrectomy? An analysis of thirty-day mortality after 21 380 nephrectomies in 3 years of the British Association of Urological Surgeons (BAUS) National Nephrectomy Audit.

    Science.gov (United States)

    Fernando, Archie; Fowler, Sarah; Van Hemelrijck, Mieke; O'Brien, Tim

    2017-09-01

    To ascertain contemporary overall and differential thirty-day mortality (TDM) rates after all types of nephrectomy in the UK, and to identify potential new risk factors for death. We conducted a retrospective analysis of the 110 deaths that occurred within 30 days of surgery out of the total of 21 380 nephrectomies performed, and calculated the odds ratio (OR) and 95% confidence interval (CI) for TDM based on peri-operative characteristics. The overall TDM rate was 110/21380 (0.5%). The TDM rates after radical, partial, simple nephrectomy and nephro-ureterectomy were 0.6% (63/11057), 0.1% (4/3931), 0.4% (11/2819) and 0.9% (28/3091), respectively. TDM increased with age, stage, estimated blood loss (EBL), operating time and performance status. EBL of 1-2 L was associated with a greater risk of TDM than EBL of 2-5 L (OR 1.38; 95% CI 1.03-2.24). Conversion from minimally invasive surgery was associated with higher risk than non-conversion (OR 2.53; 95% CI 1.14-4.51. Curative surgery was safer than cytoreductive surgery (OR 0.31; 95% CI 0.18-0.54). There was an association between surgical volume and TDM. This study provides contemporary insights into the true risks of all types of nephrectomy. The TDM rate after nephrectomy in the UK appears acceptably low at 0.5%. Established risk factors were confirmed and the following novel risk factors were identified: modest EBL (1-2 L) and conversion from minimally invasive surgery. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  5. Internal validation of the renal pelvic score: a novel marker of renal pelvic anatomy that predicts urine leak after partial nephrectomy.

    Science.gov (United States)

    Tomaszewski, Jeffrey J; Smaldone, Marc C; Cung, Bic; Li, Tianyu; Mehrazin, Reza; Kutikov, Alexander; Canter, Daniel J; Viterbo, Rosalia; Chen, David Y T; Greenberg, Richard E; Uzzo, Robert G

    2014-08-01

    To internally validate the renal pelvic score (RPS) in an expanded cohort of patients undergoing partial nephrectomy (PN). Our prospective institutional renal cell carcinoma database was used to identify all patients undergoing PN for localized renal cell carcinoma from 2007 to 2013. Patients were classified by RPS as having an intraparenchymal or extraparenchymal renal pelvis. Multivariate logistic regression models were used to examine the relationship between RPS and urine leak. Eight hundred thirty-one patients (median age, 60 ± 11.6 years; 65.1% male) undergoing PN (57.3% robotic) for low (28.9%), intermediate (56.5%), and high complexity (14.5%) localized renal tumors (median size, 3.0 ± 2.3 cm; median nephrometry score, 7.0 ± 2.6) were included. Fifty-four patients (6.5%) developed a clinically significant or radiographically identified urine leak. Seventy-two of 831 renal pelvises (8.7%) were classified as intraparenchymal. Intrarenal pelvic anatomy was associated with a markedly increased risk of urine leak (43.1% vs 3.0%; P renal pelvis; odds ratio [OR], 24.8; confidence interval [CI], 11.5-53.4; P Renal pelvic anatomy as measured by the RPS best predicts urine leak after open and robotic partial nephrectomy. Although external validation of the RPS is required, preoperative identification of patients at increased risk for urine leak should be considered in perioperative management and counseling algorithms. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Impact of arterial occlusion during partial nephrectomy on residual renal function. An evaluation with {sup 99m}technetium-dimercaptosuccinic acid scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Tsunenori; Nakazawa, Hayakazu; Ito, Fumio; Onitsuka, Shiro; Ryoji, Osamu; Yago, Rie; Hashimoto, Yasunobu; Toma, Hiroshi [Tokyo Women' s Medical Coll. (Japan)

    2002-08-01

    Partial nephrectomy (PNx) has been performed with temporary renal arterial occlusion and in situ renal hypothermia (conventional PNx). However, the impact of temporary renal arterial occlusion on residual renal function has not been well assessed. To address this question, we performed renal scintigraphy with {sup 99m}technetium-dimercaptosuccinic acid (DMSA) for the quantitative measurement of postoperative residual renal function after conventional PNx and partial nephrectomy without arterial occlusion (non-clamping PNx). Thirty-four patients underwent postoperative DMSA scintigraphy after PNx for renal cell carcinoma. No obvious difference in preoperative renal function between the diseased kidney and the contralateral kidney was found in any of the patients. Of these patients, 24 underwent conventional PNx, and 10 underwent non-clamping PNx. Residual renal function was evaluated using the relative DMSA uptake of the operated kidney. The relative DMSA uptake of the operated kidney was 39.9{+-}7.3% (25.1-58.8) after conventional PNx compared to 34.8{+-}8.9% (13.5-45.5) after non-clamping PNx. This difference was not statistically significant (P=0.15). Total ischemic time during conventional PNx had no adverse influence on the residual renal function. In the analysis of the other determinant factors influencing residual renal function, tumor size was the only significant factor that inversely correlated with the relative DMSA uptake. Our results showed that arterial clamping during PNx has no negative impact on the functional residual capacity as long as in situ renal hypothermia is adequately performed. (author)

  7. Visual Enhancement of Laparoscopic Partial Nephrectomy With 3-Charge Coupled Device Camera: Assessing Intraoperative Tissue Perfusion and Vascular Anatomy by Visible Hemoglobin Spectral Response

    Science.gov (United States)

    2010-10-01

    reliably distinguish vascular structures during hilar dissection, and detect and monitor changes in renal tissue perfus:ion dw·ing and after warm...and in 25 patients with hilar tu- mors 16 in whom perioperative outcomes were com- parable to those of peripheral tumors. In a retro- spective study...Richstone et al also reported the safe performance of LPN for hilar tumors in 17 patients.17 Repeat partial nephrectomy for ipsilat- eral tumor has

  8. Laparoscopic partial nephrectomy for endophytic hilar tumors: feasibility and outcomes.

    Science.gov (United States)

    Di Pierro, G B; Tartaglia, N; Aresu, L; Polara, A; Cielo, A; Cristini, C; Grande, P; Gentile, V; Grosso, G

    2014-06-01

    To analyze feasibility and outcomes of laparoscopic partial nephrectomy (LPN) for endophytic hilar tumors in low-intermediate (ASA I-II) risk patients. This is a single centre retrospective study. From May 2009 to September 2011, 208 LPNs were performed at our institution. Overall 11 (5.2%) elective LPNs were for hilar tumors not visible on kidney surface. Hilar tumor was defined as a mass located in the renal hilum and in contact with a major renal vessel on preoperative imaging. Procedures were carried out by a single experienced surgeon (G.G.) via retroperitoneal approach by clamping the only main renal artery. Mean (range) age of patients was 45.3 years (38.2-64.1), tumor size 1.6 cm (1.2-2.0), warm ischemia time 24 min (19-32), operative time 140 min (110-200) and estimated blood loss 270 ml (100-750). Two collecting system injuries were observed and repaired intraoperatively. No conversion to open surgery was required. Final pathological examination revealed 10 renal cell carcinomas and 1 oncocytoma. A negative surgical margin was obtained in 10/11 (91%) patients. Renal function and serum hemoglobin were nearly unaltered pre and post-surgery. No tumor recurrence was observed at mean (range) follow-up of 34 months (15-43). In experienced hands, LPN represents a feasible, safe and effective treatment for selected patients diagnosed with endophytic hilar masses. A larger number of patients and longer follow-up are required to draw definitive conclusions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Robotic-assisted partial nephrectomy: surgical technique using a 3-arm approach and sliding-clip renorrhaphy

    Directory of Open Access Journals (Sweden)

    Jose M. Cabello

    2009-04-01

    Full Text Available INTRODUCTION: For the treatment of renal tumors, minimally invasive nephron-sparing surgery has become increasingly performed due to proven efficiency and excellent functional and oncological outcomes. The introduction of robotics into urologic laparoscopic surgery has allowed surgeons to perform challenging procedures in a reliable and reproducible manner. We present our surgical technique for robotic assisted partial nephrectomy (RPN using a 3-arm approach, including a sliding-clip renorrhaphy. MATERIAL AND METHODS: Our RPN technique is presented which describes the trocar positioning, hilar dissection, tumor identification using intraoperative ultrasound for margin determination, selective vascular clamping, tumor resection, and reconstruction using a sliding-clip technique. CONCLUSION: RPN using a sliding-clip renorrhaphy is a valid and reproducible surgical technique that reduces the challenge of the procedure by taking advantage of the enhanced visualization and control afforded by the robot. The renorrhaphy described is performed under complete control of the console surgeon, and has demonstrated a reduction in the warm ischemia times in our series.

  10. Does training of fellows affect peri-operative outcomes of robot-assisted partial nephrectomy?

    Science.gov (United States)

    Khene, Zine-Eddine; Peyronnet, Benoit; Bosquet, Elise; Pradère, Benjamin; Robert, Corentin; Fardoun, Tarek; Kammerer-Jacquet, Solène-Florence; Verhoest, Grégory; Rioux-Leclercq, Nathalie; Mathieu, Romain; Bensalah, Karim

    2017-10-01

    To evaluate the impact of fellows' involvement on the peri-operative outcomes of robot-assisted partial nephrectomy (RAPN). We analysed 216 patients who underwent RAPN for a small renal tumour. We stratified our cohort into two groups according to the involvement of a fellow surgeon during the procedure: expert surgeon operating alone (expert group) and fellow operating under the supervision of the expert surgeon (fellow group). Peri-operative data were compared between the two groups. Linear and logistic regression analyses were performed to assess the impact of fellows' involvement on peri-operative and postoperative outcomes. Trifecta and margins ischaemia complications (MIC) score achievement rates were used to assess the quality of surgery in both the expert and fellow groups. Trifecta was defined as a combination of warm ischaemia time negative surgical margins and no peri-operative complications. MIC score was defined as negative surgical margins, ischaemia time Training fellows to perform RAPN is associated with longer operating time and WIT but does not appear to compromise other peri-operative outcomes. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  11. Bilateral adrenal hemorrhage due to heparin-induced thrombocytopenia following partial nephrectomy – a case report [v1; ref status: indexed, http://f1000r.es/2pn

    Directory of Open Access Journals (Sweden)

    Ashley G. Winter

    2014-01-01

    Full Text Available Heparin-induced thrombocytopenia (HIT can cause severe life-threatening events such as bilateral adrenal hemorrhage (BAH. A 48-year-old female developed a pulmonary embolus (PE following partial nephrectomy. The anticoagulation treatment for her PE was complicated by HIT and subsequent BAH. To the author’s knowledge, this is the first reported case of HIT-associated BAH following renal surgery.

  12. Robot-assisted Partial Nephrectomy: 5-yr Oncological Outcomes at a Single European Tertiary Cancer Center.

    Science.gov (United States)

    Vartolomei, Mihai Dorin; Matei, Deliu Victor; Renne, Giuseppe; Tringali, Valeria Maria; Crisan, Nicolae; Musi, Gennaro; Mistretta, Francesco Alessandro; Russo, Andrea; Cozzi, Gabriele; Cordima, Giovani; Luzzago, Stefano; Cioffi, Antonio; Di Trapani, Ettore; Catellani, Michele; Delor, Maurizio; Bottero, Danilo; Imbimbo, Ciro; Mirone, Vincenzo; Ferro, Matteo; de Cobelli, Ottavio

    2017-10-27

    Nowadays, there is a debate about which surgical treatment should be best for clinical T1 renal tumors. If the oncological outcomes are considered, there are many open and laparoscopic series published. As far as robotic series are concerned, only a few of them report 5-yr oncological outcomes. The aim of this study was to analyze robot-assisted partial nephrectomy (RAPN) midterm oncological outcomes achieved in a tertiary robotic reference center. Between April 2009 and September 2013, 123 consecutive patients with clinical T1-stage renal masses underwent RAPN in our tertiary cancer center. Inclusion criteria were as follows: pathologically confirmed renal cell carcinomas (RCCs) and follow-up for >12 mo. Eighteen patients were excluded due to follow-up of <12 mo and 15 due to benign final pathology. Median follow-up was 59 mo (interquartile range 44-73 mo). Patients were followed according to guideline recommendations and institutional protocol. Outcomes were measured by time to disease progression, overall survival, or time to cancer-specific death. Kaplan-Meier method was used to estimate survival; log-rank tests were applied for pair-wise comparison of survival. From the 90 patients included, 66 (73.3%) had T1a, 12 (13.3%) T1b, three (3.3%) T2a, and nine (10%) T3a tumors. Predominant histological type was clear cell carcinoma: 67 (74.5%). Fuhrmann grade 1 and 2 was found in 73.3% of all malignant tumors. Two patients (2.2%) had positive surgical margins, and complication rate was 17.8%. Relapse rate was 7.7%, including two cases (2.2%) of local recurrences and five (5.5%) distant metastasis. Five-year disease-free survival was 90.9%, 5-yr cancer-specific survival was 97.5%, and 5-yr overall survival was 95.1%. Midterm oncological outcomes after RAPN for localized RCCs (predominantly T1a tumors of low anatomic complexity) were shown to be good, adding significant evidence to support the oncological efficacy and safety of RAPN for the treatment of this type of

  13. Robotic unclamped "minimal-margin" partial nephrectomy: ongoing refinement of the anatomic zero-ischemia concept.

    Science.gov (United States)

    Satkunasivam, Raj; Tsai, Sheaumei; Syan, Sumeet; Bernhard, Jean-Christophe; de Castro Abreu, Andre Luis; Chopra, Sameer; Berger, Andre K; Lee, Dennis; Hung, Andrew J; Cai, Jie; Desai, Mihir M; Gill, Inderbir S

    2015-10-01

    Anatomic partial nephrectomy (PN) techniques aim to decrease or eliminate global renal ischemia. To report the technical feasibility of completely unclamped "minimal-margin" robotic PN. We also illustrate the stepwise evolution of anatomic PN surgery with related outcomes data. This study was a retrospective analysis of 179 contemporary patients undergoing anatomic PN at a tertiary academic institution between October 2009 and February 2013. Consecutive consented patients were grouped into three cohorts: group 1, with superselective clamping and developmental-curve experience (n = 70); group 2, with superselective clamping and mature experience (n = 60); and group 3, which had completely unclamped, minimal-margin PN (n = 49). Patients in groups 1 and 2 underwent superselective tumor-specific devascularization, whereas patients in group 3 underwent completely unclamped minimal-margin PN adjacent to the tumor edge, a technique that takes advantage of the radially oriented intrarenal architecture and anatomy. Primary outcomes assessed the technical feasibility of robotic, completely unclamped, minimal-margin PN; short-term changes in estimated glomerular filtration rate (eGFR); and development of new-onset chronic kidney disease (CKD) stage >3. Secondary outcome measures included perioperative variables, 30-d complications, and histopathologic outcomes. Demographic data were similar among groups. For similarly sized tumors (p = 0.13), percentage of kidney preserved was greater (p = 0.047) and margin width was narrower (p = 0.0004) in group 3. In addition, group 3 had less blood loss (200, 225, and 150ml; p = 0.04), lower transfusion rates (21%, 23%, and 4%; p = 0.008), and shorter hospital stay (p = 0.006), whereas operative time and 30-d complication rates were similar. At 1-mo postoperatively, median percentage reduction in eGFR was similar (7.6%, 0%, and 3.0%; p = 0.53); however, new-onset CKD stage >3 occurred less frequently in group 3 (23%, 10%, and 2%; p = 0

  14. Robotic partial nephrectomy with intracorporeal renal hypothermia using ice slush.

    Science.gov (United States)

    Kaouk, Jihad H; Samarasekera, Dinesh; Krishnan, Jayram; Autorino, Riccardo; Acka, Oktay; Brando, Luis Felipe; Laydner, Humberto; Zargar, Homayoun

    2014-09-01

    To outline our technique for intracorporeal cooling with ice slush during robotic partial nephrectomy (RPN), with real-time parenchymal temperature monitoring. Eleven consecutive patients with enhancing solid renal masses suitable for treatment with RPN between September 2013 and January 2014 were included in the analysis. Institutional review board approval and informed consent were obtained. Preoperative patient characteristics, intraoperative surgical parameters including patient body temperature and ipsilateral kidney temperature with real-time monitoring, and short-term functional outcomes were analyzed. Median age was 55 years (range, 39-75 years) and American Society of Anesthesiologists score was 3 (range, 2-4). Median tumor size was 4 cm (range, 2.3-7.1) and RENAL nephrometry score was 9 (range, 5-11). One patient had a solitary kidney. During cooling, the lowest median renal parenchymal temperature was 17.05°C (range, 11°C-26°C) and cold ischemia time was 27.17 minutes (range, 18-49 minutes). Median time to latest postoperative estimated glomerular filtration rate was 12 days (range, 2-30 days). Median glomerular filtration rate preservation was 81% (range, 47.9%-126%). There was one positive margin. There were no postoperative complications, and no patients experienced a prolonged ileus. The limitations of this study include a small number of patients and short-term follow-up. RPN with renal hypothermia using intracorporeal ice slush is technically feasible. Our simplified method of introducing the ice slush was free of complications and highly reproducible. The use of a needle temperature probe allowed us to monitor in real time cooling of the renal parenchyma. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Laparoscopic partial nephrectomy for hilar tumors: oncologic and renal functional outcomes.

    Science.gov (United States)

    George, Arvin K; Herati, Amin S; Rais-Bahrami, Soroush; Waingankar, Nikhil; Kavoussi, Louis R

    2014-01-01

    To present our experience with laparoscopic partial nephrectomy (LPN) for hilar tumors and evaluate intermediate oncologic and renal functional outcomes. A retrospective review of LPN cases performed in 488 patients was performed. Hilar lesions were defined as renal cortical tumors in direct physical contact with the renal artery, vein, or both, as identified on preoperative imaging and confirmed intraoperatively. The clinicopathologic parameters, perioperative course, complications, and oncologic and 6-month renal functional outcomes were analyzed. A total of 488 patients underwent LPN, of which 43 were hilar. The mean tumor size for hilar and nonhilar tumors was 3.6 cm and 3.1 cm, respectively. The mean operative time was shorter for hilar as compared with nonhilar tumors (129.1 minutes vs 141.8 minutes). Mean estimated blood loss was greater in LPN for hilar tumors (311.65 mL vs 298.4 mL). There were no statistically significant differences noted in any of the perioperative parameters investigated despite a higher nephrometry complexity score in the hilar group. Change in estimated glomerular filtration rate at 6 months showed a decrease of 10.9 mL/min and 8.8 mL/min for hilar and nonhilar tumors, respectively (P = NS). There was 1 recurrence detected in the hilar group, with a median follow-up of 41.6 months. In the hands of an experienced laparoscopist, LPN can safely be performed for hilar tumors, with preservation of perioperative outcomes and durable renal functional and oncologic outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Mini-flank supra-12th rib incision for open partial nephrectomy for renal tumor with RENAL nephrometry score ≥10: an innovation of traditional open surgery.

    Science.gov (United States)

    Wang, Hang; Sun, Li-an; Wang, Yiwei; Xiang, Zhuoyi; Zhou, Lin; Guo, Jianming; Wang, Guomin

    2015-04-01

    The skill of supra-12th rib mini-flank approach for open partial nephrectomy (MI-OPN) provides an advanced operative method for renal tumor. Compared with laparoscopic and robotic surgery, it may be a feasible selection for the complex renal tumors. We describe our techniques and results of MI-OPN in complex renal tumors with high RENAL nephrometry score (RENAL nephrometry score ≥10). Fifty-five patients diagnosed with renal tumors between January 2009 and July 2013 were included in this study. Eligibility criteria comprised of patients with complex renal tumor (RENAL score ≥10) being candidates for partial nephrectomy (PN). All patients received MI-OPN and all surgeries were performed by a single urologist. The preoperative workup comprised of medical history, physical examination, and routine laboratory tests. Serum creatinine was recorded preoperatively and 2 to 3 months after operation. Operative time, ischemia time, blood loss, operative and postoperative complications, renal function, and pathology parameters were recorded. MI-OPN was successfully performed in all cases. Mean tumor size was 4.7 cm (range: 2.5-8.1). Mean warm ischemia time was 28.1 minutes (range: 21-39), mean operative time was 105 minutes (range: 70-150) and mean estimated blood loss was 68 mL (range: 10-400). Mean postoperative hospital stay was 6.5 days (range: 5-12). Postoperative complications were found in 3 patients (5.5%). The mean pre- and postoperative serum creatinine levels were 76.2 μmol/L (range: 47-132) and 87.1 μmol/L (range: 61-189) with significant difference (P = 0.004). The mean pre- and postoperative estimated glomerular filtration rate (eGFR) were 91.5 (range: 34-133) and 82.5 (range: 22-126.5), respectively with significant difference (P = 0.024). In an average follow-up of 19.9 months (range: 8-50), no local recurrence or systemic progression occurred. In conclusion, MI-OPN can combine the benefits of both minimal invasive and traditional open

  17. The effect of zero-ischaemia laparoscopic minimally invasive partial nephrectomy using the modified sequential preplaced suture renorrhaphy technique on long-term renal functions.

    Science.gov (United States)

    Sönmez, Mehmet Giray; Kara, Cengiz

    2017-09-01

    Laparoscopic minimally invasive partial nephrectomy (MIPN) is the preferred technique in renal surgery, especially T1 phase kidney tumours, and it is recommended for the protection of renal functions in methods that do not involve ischaemia. To evaluate long-term renal functions of zero-ischaemia laparoscopic MIPN patients who underwent a modified sequential preplaced suture renorrhaphy technique. In a total of 17 renal units in 16 patients with kidney tumours that were determined incidentally and did not cause any complaints, the masses were extracted via laparoscopic partial nephrectomy (LPN) using the modified sequential preplaced suture renorrhaphy technique. Creatinine and estimated glomerular filtration rate (eGFR) values of the patients were measured preoperatively and on the first day and after 12 months postoperatively, and the results were compared. The differences between the pre- and postoperative values were statistically significant (p = 0.033, p = 0.045), but the changes in postoperative creatinine and eGFR values were clinically insignificant. While the differences between preoperative and first-day postoperative creatinine and eGFR values were found to be statistically significant (p = 0.039, p = 0.042, respectively), a statistically significant difference was not detected between preoperative and 12-month postoperative creatinine and eGFR values (p = 0.09, p = 0.065, respectively). The global percentage of functional recovery was measured as 92.5% on the first day and 95.9% at the 12 th month. The modified sequential preplaced suture renorrhaphy technique is an effective, reliable method for avoiding complications and preserving renal functions and nephrons in appropriate patients.

  18. Objective measures of renal mass anatomic complexity predict rates of major complications following partial nephrectomy.

    Science.gov (United States)

    Simhan, Jay; Smaldone, Marc C; Tsai, Kevin J; Canter, Daniel J; Li, Tianyu; Kutikov, Alexander; Viterbo, Rosalia; Chen, David Y T; Greenberg, Richard E; Uzzo, Robert G

    2011-10-01

    The association between tumor complexity and postoperative complications after partial nephrectomy (PN) has not been well characterized. We evaluated whether increasing renal tumor complexity, quantitated by nephrometry score (NS), is associated with increased complication rates following PN using the Clavien-Dindo classification system (CCS). We queried our prospectively maintained kidney cancer database for patients undergoing PN from 2007 to 2010 for whom NS was available. All patients underwent PN. Tumors were categorized into low- (NS: 4-6), moderate- (NS: 7-9), and high-complexity (NS: 10-12) lesions. Complication rates within 30 d were graded (CCS: I-5), stratified as minor (CCS: I or 2) or major (CCS: 3-5), and compared between groups. A total of 390 patients (mean age: 58.0 ± 11.9 yr; 66.9% male) undergoing PN (44.6% open, 55.4% robotic) for low- (28%), moderate- (55.6%), and high-complexity (16.4%) tumors (mean tumor size: 3.74 ± 2.4 cm; median: 3.2 cm) from 2007 to 2010 were identified. Tumor size, estimated blood loss, and ischemia time all significantly differed (prenal tumors. Copyright © 2011 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  19. Spontaneous Retroperitoneal Hemorrhage (Wunderlich Syndrome due to Large Upper Pole Renal Angiomyolipoma: Does Robotic-Assisted Laparoscopic Partial Nephrectomy Have a Role in Primary Treatment?

    Directory of Open Access Journals (Sweden)

    Achilles Ploumidis

    2013-01-01

    Full Text Available Spontaneous rapture with consequent retroperitoneal hemorrhage (Wunderlich’s syndrome is the complication mostly feared from large renal angiomyolipomas (RAMLs. In hemodynamic stable patients, minimal invasive therapies have superseded open surgery as the mainstay of treatment, with contemporary cases mostly treated by selective arterial embolization. Robotic-assisted laparoscopic partial nephrectomy (RALPN is an established minimal access treatment that has been used in the past for benign and malignant lesions of the kidney in the elective setting, but rarely in urgent situations as primary treatment. We present a case of a ruptured RAML in a young female treated effectively by RALPN.

  20. Laparoscopic donor nephrectomy

    Directory of Open Access Journals (Sweden)

    Gupta Nitin

    2005-01-01

    Full Text Available Of the various options for patients with end stage renal disease, kidney transplantation is the treatment of choice for a suitable patient. The kidney for transplantation is retrieved from either a cadaver or a live donor. Living donor nephrectomy has been developed as a method to address the shortfall in cadaveric kidneys available for transplantation. Laparoscopic living donor nephrectomy (LLDN, by reducing postoperative pain, shortening convalescence, and improving the cosmetic outcome of the donor nephrectomy, has shown the potential to increase the number of living kidney donations further by removing some of the disincentives inherent to donation itself. The technique of LLDN has undergone evolution at different transplant centers and many modifications have been done to improve donor safety and recipient outcome. Virtually all donors eligible for an open surgical procedure may also undergo the laparoscopic operation. Various earlier contraindications to LDN, such as right donor kidney, multiple vessels, anomalous vasculature and obesity have been overcome with increasing experience. Laparoscopic live donor nephrectomy can be done transperitoneally or retroperitoneally on either side. The approach is most commonly transperitoneal, which allows adequate working space and easy dissection. A review of literature and our experience with regards to standard approach and the modifications is presented including a cost saving model for the developing countries. An assessment has been made, of the impact of LDN on the outcome of donor and the recipient.

  1. Use of the Satinsky clamp for hilar clamping during robotic partial nephrectomy: indications, technique, and multi-center outcomes.

    Science.gov (United States)

    Abdullah, Newaj; Rahbar, Haider; Barod, Ravi; Dalela, Deepansh; Larson, Jeff; Johnson, Michael; Mass, Alon; Zargar, Homayoun; Kaouk, Jihad; Allaf, Mohamad; Bhayani, Sam; Stifelman, Michael; Rogers, Craig

    2017-03-01

    A Satinsky clamp may be a backup option for hilar clamping during robotic partial nephrectomy (RPN) if there are challenges with application of bulldog clamps, but there are potential safety concerns. We evaluate outcomes of RPN using Satinsky vs. bulldog clamps, and provide tips for safe use of the Satinsky as a backup option. Using a multi-center database, we identified 1073 patients who underwent RPN between 2006 and 2013, and had information available about method of hilar clamping (bulldog clamp vs. Satinsky clamp). Patient baseline characteristics, tumor features, and perioperative outcomes were compared between the Satinsky and bulldog clamp groups. A Satinsky clamp was used for hilar clamping in 94 (8.8 %) RPN cases, and bulldog clamps were used in 979 (91.2 %) cases. The use of a Satinsky clamp was associated with greater operative time (198 vs. 175 min, p hilar clamping during challenging RPN cases, but requires careful technique, and was rarely necessary.

  2. 'Trifecta' outcomes of robot-assisted partial nephrectomy in solitary kidney: a Vattikuti Collective Quality Initiative (VCQI) database analysis.

    Science.gov (United States)

    Arora, Sohrab; Abaza, Ronney; Adshead, James M; Ahlawat, Rajesh K; Challacombe, Benjamin J; Dasgupta, Prokar; Gandaglia, Giorgio; Moon, Daniel A; Yuvaraja, Thyavihally B; Capitanio, Umberto; Larcher, Alessandro; Porpiglia, Francesco; Porter, James R; Mottrie, Alexander; Bhandari, Mahendra; Rogers, Craig

    2018-01-01

    To analyse the outcomes of robot-assisted partial nephrectomy (RAPN) in patients with a solitary kidney in a large multi-institutional database. In all, 2755 patients in the Vattikuti Collective Quality Initiative database underwent RAPN by 22 surgeons at 14 centres in nine countries. Of these patients, 74 underwent RAPN with a solitary kidney between 2007 and 2016. We retrospectively analysed the functional and oncological outcomes of these 74 patients. A 'trifecta' of outcomes was assessed, with trifecta defined as a warm ischaemia time (WIT) of negative surgical margins, and no complications intraoperatively or within 3 months of RAPN. All 74 patients underwent RAPN successfully with one conversion to radical nephrectomy. The median (interquartile range [IQR]) operative time was 180 (142-230) min. Early unclamping was used in 11 (14.9%) patients and zero ischaemia was used in 12 (16.2%). Trifecta outcomes were achieved in 38 of 66 patients (57.6%). The median (IQR) WIT was 15.5 (8.75-20.0) min for the entire cohort. The overall complication rate was 24.1% and the rate of Clavien-Dindo grade ≤II complications was 16.3%. Positive surgical margins were present in four cases (5.4%). The median (IQR) follow-up was 10.5 (2.12-24.0) months. The median drop in estimated glomerular filtration rate at 3 months was 7.0 mL/min/1.72 m 2 (11.01%). Our findings suggest that RAPN is a safe and effective treatment option for select renal tumours in solitary kidneys in terms of a trifecta of negative surgical margins, WIT of <20 min, and low operative and perioperative morbidity. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  3. Generation of Chimeric “ABS Nanohemostat” Complex and Comparing Its Histomorphological In Vivo Effects to the Traditional Ankaferd Hemostat in Controlled Experimental Partial Nephrectomy Model

    Directory of Open Access Journals (Sweden)

    Emre Huri

    2013-01-01

    Full Text Available Purpose. Using the classical Ankaferd Blood Stopper (ABS solution to create active hemostasis during partial nephrectomy (PN may not be so effective due to insufficient contact surface between the ABS hemostatic liquid agent and the bleeding area. In order to broaden the contact surface, we generated a chimeric hemostatic agent, ABS nanohemostat, via combining a self-assembling peptide amphiphile molecule with the traditional Ankaferd hemostat. Materials and Methods. In order to generate ABS nanohemostat, a positively charged Peptide Amphiphile (PA molecule was synthesized by using solid phase peptide synthesis. For animal experiments, 24 Wistar rats were divided into the following 4 groups: Group 1: control; Group 2: conventional PN with only 0.5 ml Ankaferd hemostat; Group 3: conventional PN with ABS + peptide gel; Group 4: conventional PN with only 0.5 ml peptide solution. Results. Mean warm ischemia times (WITs were 232.8 ± 56.3, 65.6±11.4, 75.5± 17.2, and 58.1±17.6 seconds in Group 1 to Group 4, respectively. Fibrosis was not different among the groups, while inflammation was detected to be significantly different in G3 and G4. Conclusions. ABS nanohemostat has comparable hemostatic efficacy to the traditional Ankaferd hemostat in the partial nephrectomy experimental model. Elucidation of the cellular and tissue effects of this chimeric compound may establish a catalytic spark and open new avenues for novel experimental and clinical studies in the battlefield of hemostasis.

  4. High-fidelity simulation-based team training in urology: evaluation of technical and nontechnical skills of urology residents during laparoscopic partial nephrectomy.

    Science.gov (United States)

    Abdelshehid, Corollos S; Quach, Stephen; Nelson, Corey; Graversen, Joseph; Lusch, Achim; Zarraga, Jerome; Alipanah, Reza; Landman, Jaime; McDougall, Elspeth M

    2013-01-01

    The use of low-risk simulation training for resident education is rapidly expanding as teaching centers integrate simulation-based team training (SBTT) sessions into their education curriculum. SBTT is a valuable tool in technical and communication skills training and assessment for residents. We created a unique SBTT scenario for urology residents involving a laparoscopic partial nephrectomy procedure. Urology residents were randomly paired with a certified registered nurse anesthetists or an anesthesia resident. The scenario incorporated a laparoscopic right partial nephrectomy utilizing a unique polyvinyl alcohol kidney model with an embedded 3cm lower pole exophytic tumor and the high-fidelity SimMan3G mannequin. The Urology residents were instructed to pay particular attention to the patient's identifying information provided at the beginning of the case. Two scripted events occurred, the patient had an anaphylactic reaction to a drug and, after tumor specimen was sent for a frozen section, the confederate pathologist called into the operating room (OR) twice, first with the wrong patient name and subsequently with the wrong specimen. After the scenario was complete, technical performance and nontechnical performance were evaluated and assessed. A debriefing session followed the scenario to discuss and assess technical performance and interdisciplinary nontechnical communication between the team. All Urology residents (n = 9) rated the SBTT scenario as a useful tool in developing communication skills among the OR team and 88% rated the model as useful for technical skills training. Despite cuing to note patient identification, only 3 of 9 (33%) participants identified that the wrong patient information was presented when the confederate "pathologist" called in to report pathology results. All urology residents rated SBTT sessions as useful for the development of communication skills between different team members and making residents aware of unlikely but

  5. Surgeons' preferences and practice patterns regarding intraoperative frozen section during partial nephrectomy.

    Science.gov (United States)

    Sidana, Abhinav; Donovan, James F; Gaitonde, Krishnanath

    2014-08-01

    Intraoperative frozen section (FS) evaluation for tumor margin during partial nephrectomy (PN) is a matter of controversy in urologic oncology. We evaluated the preferences and practice patterns of urologists regarding intraoperative FS during PN. A 17-item questionnaire was designed to collect information on surgeons' preferences and practice patterns regarding FS during PN. The survey was sent to the members of the Society of Urologic Oncology and Endourological Society. A total of 197 responses were received. Overall, 69% and 58% of respondents chose to obtain FS (always or sometimes) during open PN (OPN) and laparoscopic PN (LPN), respectively. There was a strong correlation between the surgeons' preferences during OPN and LPN. Younger surgeons are less likely to obtain FS during OPN. For surgeons who did not routinely obtain FS, "confidence about complete resection" was the most common reason (79%), followed by "no change in management with positive margins" (35%). Most surgeons (75%) believed the margins to be negative, if surgical margin was free of tumor microscopically by a single cell layer. Older surgeons considered negative margins to be free of tumor microscopically by ≥5 mm. Overall, 54% and 42% of respondents would repeat FS for positive microscopic margins during OPN and LPN, respectively. Of the respondents, 95% would not recommend additional treatment for positive margins on final pathology. Despite recent literature pointing to low clinical utility of FS, most surgeons still obtain FS during PN. Older surgeons tend to obtain FS more often. Fellowship training and practice type do not appear to influence preferences and practice patterns in regard to FS. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Isolated omental metastasis of renal cell carcinoma after extraperitoneal open partial nephrectomy: A case report

    Directory of Open Access Journals (Sweden)

    Ömer Acar

    2016-01-01

    Conclusion: To our knowledge, this is the first reported case of metachronously developed, isolated omental metastasis of an initially T1 clear-cell RCC. Constitutional symptoms, despite a long interval since nephrectomy, should raise the possibility of a paraneoplastic syndrome being associated with metastatic RCC. Morphological and molecular imaging studies together with histopathological documentation will be diagnostic.

  7. Simultaneous bilateral robotic partial nephrectomy: Case report and critical evaluation of the technique.

    Science.gov (United States)

    Giberti, Claudio; Gallo, Fabrizio; Schenone, Maurizio; Cortese, Pierluigi

    2014-06-16

    We report our first simultaneous bilateral robot assisted partial nephrectomy (RAPN) in order to show and critically discuss the feasibility of this procedure. Materials and methods A 69-year-old male patient visited our department due to incidental finding of bilateral mesorenal small masses (2.5 cm on the right and 3.5 cm on the left) suspicious for malignancy. We started from the right side with patient in flank position. Port placement: 12-mm periumbilical camera port, two 8-mm robotic ports in wide ''V''configuration, additional 12 mm assistant port on the midline between the umbilicus and symphysis pubis. A right unclamping RAPN with sliding clip renorrhaphy was performed. The trocars were removed and the robot undocked. Without interrupting the anesthesiological procedures, the patient was reported in supine position and, after 180 degrees rotation of the surgical bed, was newly placed in contralateral flank position. Using both the previous periumbilical and midline ports, two other 8-mm robotic trocars were placed. The robot was then redocked and RAPN was also performed on the left side using the same previously reported technique. Results Total time: 285 min. Estimated blood losses: 150 cc. Postoperative period: uneventful. Pathological examination: bilateral renal cell carcinoma, negative surgical margins. Conclusions Our experience was encouraging and confirmed the feasibility and safety of this procedure. The planning of our technique was time and cost effective with cosmetic benefit for the patient. However, we think that an appropriate selection of the patients and a skill in robotic renal surgery are advisable before approaching this type of surgery.

  8. Multicenter Experience with Nonischemic Multiport Laparoscopic and Laparoendoscopic Single-Site Partial Nephrectomy Utilizing Bipolar Radiofrequency Ablation Coagulator

    Directory of Open Access Journals (Sweden)

    Wassim M. Bazzi

    2011-01-01

    Full Text Available Objective. To investigate feasibility of multiport and laparoendoscopic single-site (LESS nonischemic laparoscopic partial nephrectomy (NI-LPN utilizing bipolar radiofrequency coagulator. Methods. Multicenter retrospective review of 60 patients (46 multiport/14 LESS undergoing NI-LPN between 4/2006 and 9/2009. Multiport and LESS NI-LPN utilized Habib 4X bipolar radiofrequency coagulator to form a hemostatic zone followed by nonischemic tumor excision and renorrhaphy. Demographics, tumor/perioperative characteristics, and outcomes were analyzed. Results. 59/60 (98.3% successfully underwent NI-LPN. Mean tumor size was 2.35 cm. Mean operative time was 160.0 minutes. Mean estimated blood loss was 131.4 mL. Preoperative/postoperative creatinine (mg/dL was 1.02/1.07 (=.471. All had negative margins. 12 (20% patients developed complications. 3 (5% developed urine leaks. No differences between multiport and LESS-PN were noted as regards demographics, tumor size, outcomes, and complications. Conclusion. Initial experience demonstrates that nonischemic multiport and LESS-PN is safe and efficacious, with excellent short-term preservation of renal function. Long-term data are needed to confirm oncological efficacy.

  9. Laparoscopic Donor Nephrectomy: Early Experience at a Single Center in Pakistan.

    Science.gov (United States)

    Mohsin, Rehan; Shehzad, Asad; Bajracharya, Uspal; Ali, Bux; Aziz, Tahir; Mubarak, Muhammed; Hashmi, Altaf; Rizvi, Adibul Hasan

    2018-04-01

    Laparoscopic donor nephrectomy has become the criterion standard for kidney retrieval from living donors. There is no information on the experience and outcomes of laparoscopic donor nephrectomy in Pakistan. The objective of the study was to identify benefits and harms of using laparoscopic compared with open nephrectomy techniques for renal allograft retrieval. In this a retrospective study, patient files from May 2014 to September 2015 were analyzed. Patients were divided into 2 groups: those with open donor nephrectomy and those with laparoscopic donor nephrectomy. Donor case files and operative notes were analyzed for age, sex, laterality, body mass index, warm ischemia time, perioperative and postoperative complications, surgery time, and length of hospital stay. Finally, serum creatinine patterns of both donors and recipients were analyzed. Data were analyzed using SPSS version 10 (SPSS: An IBM Company, IBM Corporation, Armonk, NY, USA). Of 388 total donors, 190 (49%) had open donor nephrectomy and 198 (51%) had laparoscopic donor nephrectomy. For both groups, most donors were older than 25 years with male preponderance. Left-to-right kidney donation ratio was markedly higher in the laparoscopic group than in the open donor nephrectomy group, with 6 cases of double renal artery also included in this study. There were no significant differences in surgery times between the 2 groups, whereas the laparoscopic donor nephrectomy group had shorter hospital stay. Analgesic requirements were markedly shorter in the laparoscopic donor nephrectomy group. The 1-year graft function was not significantly different between the 2 groups. The results for laparoscopic donor nephrectomy were comparable to those for open donor nephrectomy, and its acceptability was high. Laparoscopic donor nephrectomy should be the preferred approach for procuring the kidney graft.

  10. Relief of chronic partial ureteral obstruction attenuates salt-sensitive hypertension in rats

    DEFF Research Database (Denmark)

    Carlström, M.; Wåhlin, N.; Skøtt, Ole

    2007-01-01

    shown that animals with chronic partial unilateral ureteral obstruction develop salt-sensitive hypertension. In this study, the effects of ipsilateral and contralateral nephrectomy and ureterovesicostomy on blood pressure were studied in hydronephrotic animals. METHODS: Partial unilateral ureteral...... obstruction was created in 3-week-old male Sprague-Dawley rats and blood pressure was measured telemetrically 4-6 weeks later during a normal and high salt diet before and after uninephrectomy or ureterovesicostomy. Plasma samples for renin assay were collected during both diets before and after ipsilateral...... nephrectomy. RESULTS: All hydronephrotic animals developed salt-sensitive hypertension, of different degrees. Before nephrectomy the plasma renin concentration was significantly higher in the hydronephrotic animals than in controls (160 +/- 15 microGU mL(-1) vs. 96 +/- 12 microGU mL(-1), respectively...

  11. Comparison of the significance of the RENAL, PADUA, and C-index nephrometric scales for the prediction of the complexity of laparoscopic nephrectomy

    Directory of Open Access Journals (Sweden)

    Yu. G. Alyaev

    2018-01-01

    Full Text Available Objective: to compare the predictive value of RENAL, PADUA, C-index nephrometry score systems according to projection of complexity  of operative measure in terms of warm ischaemic time, extent of blood loss and rate of postoperative complications.Materials and methods. Information for the research was collected from 314 patients with localized kidney cancer, who had laparoscopic partial nephrectomy from January 2012 to May 2017. In 210 (66.8 % cases, in addition to the routine examinations, 3D modelling and operative measure planning were carried out. The average tumor volume of the patients was equal to 62.5 ± 33.5 mm3. All patients before  the operation were estimated the complexity of operative measure on the nephrometry score systems: PADUA, RENAL, C-index. The average sum of balls according to scale RENAL – 7.56 ± 1.12, on scale PADUA – 7.98 ± 1.55, on scale C-index – 2.76 ± 1.14. Then in retrospect by the method of logistic regression analysis was determined predictive value of RENAL, PADUA, C-index nephrometry score systems for prediction of warm ischaemic time, duration of operative measure, extent of intraoperative blood loss and possibility of rate of postoperative complications.Results. In 265 (84.4 cases transperitoneal approach was perfomed and in 49 (15.6 % cases it was retroperitoneal approach. The average time of laparoscopic partial nephrectomy is 140.15 ± 55.8 min, the average time of ischaemic warm is 13.35 ± 7,65 min. The average extent of blood loss during the laparoscopic partial nephrectomy is 291.95 ± 196.5 ml. Intraoperative complications were found in 8 (2.54 % cases. Postoperative complications were estimated according to the Clavien–Dindo classification of surgical complications and were found in 31  (9.9 % cases, among them 12 (3.8 % patients had surgical complications. The index of the RENAL nephrometry scoring system had the highest predictive value in the multivariant analysis for warm ischaemic

  12. Nephrectomy (Kidney Removal)

    Science.gov (United States)

    ... nephrectomy is needed because of other kidney diseases. Kidney function Most people have two kidneys — fist-sized ... and the disease that prompted the surgery? Monitoring kidney function Most people can function well with only ...

  13. Three-dimensional renal CT angiography for guiding segmental renal artery clamping during laparoscopic partial nephrectomy

    International Nuclear Information System (INIS)

    Xu, Yi; Shao, Pengfei; Zhu, Xiaomei; Lv, Qiang; Liu, Wangyan; Xu, Hai; Zhu, Yinsu; Yang, Guangyu; Tang, Lijun; Yin, Changjun

    2013-01-01

    Aim: To evaluate the effectiveness of three-dimensional (3D) renal computed tomography angiography (CTA) in guiding segmental renal artery clamping during laparoscopic partial nephrectomy (LPN). Materials and methods: Forty-three patients with renal tumours undergoing renal CTA before LPN were retrospectively enrolled in this study. 3D arteriogram reconstructed images were created to identify the renal tumour-supplying arteries. The number and location of these targeted vessels were annotated on 3D images preoperatively and compared with the clamped vessels during LPN. The consistency between target vessels annotated at CTA and clamped arteries at LPN was compared both using a patient-based analysis and vessel-based analysis. The χ 2 test was applied to analyse the influence of tumour size, location, and growth pattern on the number of clamped segmental renal branches. Results: On patient-based analysis, the number of targeted vessels was consistent with the clamped vessels during LPN in 33 of 43 patients. On vessel-based analysis, 56 of 65 target vessels annotated at CTA were clamped during LPN. More segmental renal branches (p = 0.04) were clamped in patients with tumours of larger size. Tumour location and growth pattern had no association with the number of clamped segmental branches during LPN. Conclusion: High-quality CTA images and 3D reconstruction images can detect detailed information of tumour-supplying arteries to renal tumours. 3D renal CTA is an effective way to guide segmental renal artery clamping during LPN

  14. Analysis of 88 nephrectomies in a rural tertiary care center of India

    Directory of Open Access Journals (Sweden)

    Biswajit Datta

    2012-01-01

    Full Text Available Nephrectomy is not an uncommon surgery in day-to-day practice of urology. Trauma is the most common cause of emergency nephrectomy. On the other hand, elective nephrectomy is done for both benign and malignant diseases of the kidney. This study has been performed to know the different causes of nephrectomy in a rural, tertiary care center of India. In our series, we have studied all the elective nephrectomies done in our hospital during a period of eight years. We have analyzed 88 cases of nephrectomies regarding their age, sex, laterality of disease, and histopathologic report of the nephrectomy specimens. Out of 88 cases, 61 were males and 27 were females. In our series, 62.5% cases of nephrectomies were done for benign causes and 37.5% cases for malignant causes. Among the benign causes, neglected pelviureteric junction obstruction was the leading cause, followed by calculus disease resulting in obstruction. On the other hand, renal cell carcinoma was the most common malignant pathology requiring nephrectomy.

  15. Chylous ascites as a complication of left sided robot-assisted laparoscopic partial nephrectomy

    Directory of Open Access Journals (Sweden)

    Gaurav Pahouja

    2016-10-01

    Full Text Available Objective: The aim of the study was to present a case series of the sparsely reported complication of chylous ascites (CA after left sided robot-assisted laparoscopic partial nephrectomy (RALPN, identify possible risk factors for the development of postoperative CA, and explore current recommendations for identification, management and prevention of CA. Material and methods: A retrospective review of patients that were treated with a RALPN during a one year time period (August 2012 to August 2013 by one surgeon at our institution was conducted. A total of 12 patients were included in the study. Demographics, tumor characteristics, and perioperative outcomes were assessed. Results: Three patients in the study experienced postoperative CA. All three patients had left sided surgery. The initial clinical suspicion for CA was raised due to complaints of abdominal pain with increased milky appearance of JP fluid. JP triglycerides were elevated in all three patients. The patients responded to conservative measures, with two patients treated with medium chain triglyceride diets and one patient treated with total parenteral nutrition (TPN. Among the patients treated with RALPN, the group that was diagnosed with postoperative CA (CA group was found to have a statistically significant lower average body mass index (BMI as compared to the group that did not have CA (non-CA group (24.67 kg/m2 in the CA group versus 31.77 kg/m2 in the non-CA group; P = 0.026. Other demographic data, tumor characteristics, and perioperative outcomes were similar in both groups. Conclusions: CA as a result of RALPN is a newly reported and rare postoperative complication. As utilization of RALPN continues to increase, urologists should be aware of this possible complication and be adept at diagnosing and managing CA. We suggest that left sided retroperitoneal surgery and a lower BMI preoperatively be considered risk factors for developing this complication.

  16. Robot-Assisted Laparoendoscopic Single-Site Partial Nephrectomy With the Novel Da Vinci Single-Site Platform: Initial Experience

    Science.gov (United States)

    Komninos, Christos; Tuliao, Patrick; Kim, Dae Keun; Choi, Young Deuk; Chung, Byung Ha

    2014-01-01

    Purpose To report our initial clinical cases of robotic laparoendoscopic single-site (R-LESS) partial nephrectomy (PN) performed with the use of the novel Da Vinci R-LESS platform. Materials and Methods Three patients underwent R-LESS PN from November 2013 through February 2014. Perioperative and postoperative outcomes were collected and intraoperative difficulties were noted. Results Operative time and estimated blood loss volume ranged between 100 and 110 minutes and between 50 and 500 mL, respectively. None of the patients was transfused. All cases were completed with the off-clamp technique, whereas one case required conversion to the conventional (multiport) approach because of difficulty in creating the appropriate scope for safe tumor resection. No major postoperative complications occurred, and all tumors were resected in safe margins. Length of hospital stay ranged between 3 and 7 days. The lack of EndoWrist movements, the external collisions, and the bed assistant's limited working space were noticed to be the main drawbacks of this surgical method. Conclusions Our initial experience with R-LESS PN with the novel Da Vinci platform shows that even though the procedure is feasible, it should be applied in only appropriately selected patients. However, further improvement is needed to overcome the existing limitations. PMID:24955221

  17. Anatomic renal artery branch microdissection to facilitate zero-ischemia partial nephrectomy.

    Science.gov (United States)

    Ng, Casey K; Gill, Inderbir S; Patil, Mukul B; Hung, Andrew J; Berger, Andre K; de Castro Abreu, Andre Luis; Nakamoto, Masahiko; Eisenberg, Manuel S; Ukimura, Osamu; Thangathurai, Duraiyah; Aron, Monish; Desai, Mihir M

    2012-01-01

    Robot-assisted and laparoscopic partial nephrectomies (PNs) for medial tumors are technically challenging even with the hilum clamped and, until now, were impossible to perform with the hilum unclamped. Evaluate whether targeted vascular microdissection (VMD) of renal artery branches allows zero-ischemia PN to be performed even for challenging medial tumors. A prospective cohort evaluation of 44 patients with renal masses who underwent robot-assisted or laparoscopic zero-ischemia PN either with anatomic VMD (group 1; n=22) or without anatomic VMD (group 2; n=22) performed by a single surgeon from April 2010 to January 2011. Zero-ischemia PN with VMD incorporates four maneuvers: (1) preoperative computed tomographic reconstruction of renal arterial branch anatomy, (2) anatomic dissection of targeted, tumor-specific tertiary or higher-order renal arterial branches, (3) neurosurgical aneurysm microsurgical bulldog clamp(s) for superselective tumor devascularization, and (4) transient, controlled reduction of blood pressure, if necessary. Baseline, perioperative, and postoperative data were collected prospectively. Group 1 tumors were larger (4.3 vs 2.6 cm; p=0.011), were more often hilar (41% vs 9%; p=0.09), were medial (59% and 23%; p=0.017), were closer to the hilum (1.46 vs 3.26 cm; p=0.0002), and had a lower C index score (2.1 vs 3.9; p=0.004) and higher RENAL nephrometry scores (7.7 vs 6.2; p=0.013). Despite greater complexity, no group 1 tumor required hilar clamping, and perioperative outcomes were similar to those of group 2: operating room time (4.7 and 4.1h), median blood loss (200 and 100ml), surgical margins for cancer (all negative), major complications (0% and 9%), and minor complications (18% and 14%). The median serum creatinine level was similar 2 mo postoperatively (1.2 and 1.3mg/dl). The study was limited by the relatively small sample size. Anatomic targeted dissection and superselective control of tumor-specific renal arterial branches facilitate

  18. National nephrectomy registries: Reviewing the need for population-based data.

    Science.gov (United States)

    Pearson, John; Williamson, Timothy; Ischia, Joseph; Bolton, Damien M; Frydenberg, Mark; Lawrentschuk, Nathan

    2015-09-01

    Nephrectomy is the cornerstone therapy for renal cell carcinoma (RCC) and continued refinement of the procedure through research may enhance patient outcomes. A national nephrectomy registry may provide the key information needed to assess the procedure at a national level. The aim of this study was to review nephrectomy data available at a population-based level in Australia and to benchmark these data against data from the rest of the world as an examination of the national nephrectomy registry model. A PubMed search identified records pertaining to RCC nephrectomy in Australia. A similar search identified records relating to established nephrectomy registries internationally and other surgical registries of clinical importance. These records were reviewed to address the stated aims of this article. Population-based data within Australia for nephrectomy were lacking. Key issues identified were the difficulty in benchmarking outcomes and no ongoing monitoring of trends. The care centralization debate, which questions whether small-volume centers provide comparable outcomes to high-volume centers, is ongoing. Patterns of adherence and the effectiveness of existing protocols are uncertain. A review of established international registries demonstrated that the registry model can effectively address issues comparable to those identified in the Australian literature. A national nephrectomy registry could address deficiencies identified in a given nation's nephrectomy field. The model is supported by evidence from international examples and will provide the population-based data needed for studies. Scope exists for possible integration with other registries to develop a more encompassing urological or surgical registry. Need remains for further exploration of the feasibility and practicalities of initiating such a registry including a minimum data set, outcome indicators, and auditing of data.

  19. TECHNIQUE OF EXTRACORPOREAL PARTIAL NEPHRECTOMY IN TERMS OF PHARMACO-COLD ISCHEMIA WITHOUT CROSSING THE URETER WITH RENAL VESSELS ORTHOTOPIC REPLANTATION IN PATIENTS WITH RENAL CELL CARCINOMA

    Directory of Open Access Journals (Sweden)

    Alexander Gritskevitch

    2015-01-01

    Full Text Available Background. The most difficult is to determine medical tactics in patients with renal cell carcinoma (RCC with intraparenchimal and central localization in the single, the only functioning kidney, as well as with a combination of tumor and other illnesses in contralateral kidney. Partial nephrectomy leading to renal replacement therapy results in life-threatening complications and poor prognosis. The priority is to develop organ-preserving treatment: from minimally invasive endoscopic surgery to ex vivo kidney resection. Aim: to develop a technique of extracorporeal partial nephrectomy in terms of pharmaco-cold ischemia without crossing the ureter with renal vessels orthotopic replantation in patients with RCC. Materials and methods. The study included 37 patients with pT1a-T3vN0M0-1G1-3 RCC with intraparenchymal and central tumor location. The average age of the patients was 55.32 ± 13.1 years. The ratio of men and women - 2.7:1. Bilateral renal tumors were observed in 3 (8.1% patients, and the RCC of the single functioning kidney in 6 (16.2% patients. One patient (2.7% was diagnosed RCC of a single kidney with intraluminal invasion (cava-renal form. Results. The mean operation time was 413.97 ± 89.14 minutes. The mean warm ischemia time – 8.39 ± 4.75 minutes. Cold ischemia lasted from 70 to 240 minutes, on the average 151.41 ± 41.29 min. The amount of blood loss made up 729.03 ± 481.4 ml. Perioperative complications were detected in 3 (8.1% patients. In two cases after starting the renal blood flow the kidney was found to be nonviable and had to be removed. And in one case the recurrent prosthetic thrombosis of the renal artery resulted in a renal scarring. Postoperative complications were observed in 18 (48.6% patients. According to Clavien-Dindo classification there were 8 low grade (I-II degree complications (44.4%, 8 other of III degree, and one IV degree complication, and there was one lethal case (V degree. Conclusion

  20. Intraoperative evaluation of renal blood flow during laparoscopic partial nephrectomy with a novel Doppler system.

    Science.gov (United States)

    Mues, Adam C; Okhunov, Zhamshid; Badani, Ketan; Gupta, Mantu; Landman, Jaime

    2010-12-01

    Hemostasis remains a major challenge associated with laparoscopic renal surgery. We evaluated a cost-effective novel Doppler probe (DP) for assessment of vascular control during laparoscopic partial nephrectomy (LPN). We prospectively collected data during LPN procedures. We documented tumor location and size as well as subjective quality of the hilar dissection. The DP was compared with our standard intraoperative ultrasound system (SUS) for the ability to detect blood flow during hilar dissection and to determine parenchymal ischemia around the tumor after clamping of the renal vessels. Twenty patients underwent LPN by a single surgeon. The mean tumor size was 3.0 cm (range: 1.2-6.3 cm). The times to assess the kidney using the SUS and DP were 68.6 seconds (range: 20-155) and 44.5 seconds (range: 15-180), respectively. Evaluation prior to renal hilar clamping demonstrated the presence of blood flow in all 20 patients (100%) using the SUS and in 17 of 20 (85%) using the DP. Similarly, cessation of blood flow with clamping was documented in 100% of cases with SUS and 85% with DP. Persistent flow was detected by both SUS and DP in two patients requiring further dissection and reclamping. Then, both systems detected the absence of flow before tumor resection. With blood flow interruption confirmation, no patient had significant bleeding at the time of renal parenchymal transection. Intraoperative Doppler ultrasound technologies minimize the risk of significant bleeding during LPN. The DP is a small, simple, effective probe that can be used to assess blood flow interruption to the kidney during laparoscopic renal surgery.

  1. Indications, Complications and Mortality of Nephrectomy in Tikur ...

    African Journals Online (AJOL)

    Background: Nephrectomy is a standard therapeutic urological procedure for malignancy of kidneys and upper urinary tract, and for damaged kidneys with little or no contribution to the overall renal function. There are geographical variations in indications for nephrectomy as certain urological diseases are more prevalent in ...

  2. File list: Unc.Kid.50.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Kid.50.AllAg.Nephrectomy_sample hg19 Unclassified Kidney Nephrectomy sample htt...p://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.Kid.50.AllAg.Nephrectomy_sample.bed ...

  3. File list: DNS.Kid.05.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Kid.05.AllAg.Nephrectomy_sample hg19 DNase-seq Kidney Nephrectomy sample http:/.../dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.Kid.05.AllAg.Nephrectomy_sample.bed ...

  4. File list: Unc.Kid.10.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Kid.10.AllAg.Nephrectomy_sample hg19 Unclassified Kidney Nephrectomy sample htt...p://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.Kid.10.AllAg.Nephrectomy_sample.bed ...

  5. File list: DNS.Kid.50.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Kid.50.AllAg.Nephrectomy_sample hg19 DNase-seq Kidney Nephrectomy sample http:/.../dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.Kid.50.AllAg.Nephrectomy_sample.bed ...

  6. File list: Unc.Kid.20.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Kid.20.AllAg.Nephrectomy_sample hg19 Unclassified Kidney Nephrectomy sample htt...p://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.Kid.20.AllAg.Nephrectomy_sample.bed ...

  7. File list: Pol.Kid.20.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Kid.20.AllAg.Nephrectomy_sample hg19 RNA polymerase Kidney Nephrectomy sample h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Kid.20.AllAg.Nephrectomy_sample.bed ...

  8. File list: Pol.Kid.10.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Kid.10.AllAg.Nephrectomy_sample hg19 RNA polymerase Kidney Nephrectomy sample h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Kid.10.AllAg.Nephrectomy_sample.bed ...

  9. File list: Pol.Kid.05.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Kid.05.AllAg.Nephrectomy_sample hg19 RNA polymerase Kidney Nephrectomy sample h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Kid.05.AllAg.Nephrectomy_sample.bed ...

  10. File list: Oth.Kid.10.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Kid.10.AllAg.Nephrectomy_sample hg19 TFs and others Kidney Nephrectomy sample h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.Kid.10.AllAg.Nephrectomy_sample.bed ...

  11. File list: Oth.Kid.50.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Kid.50.AllAg.Nephrectomy_sample hg19 TFs and others Kidney Nephrectomy sample h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.Kid.50.AllAg.Nephrectomy_sample.bed ...

  12. File list: Oth.Kid.05.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Kid.05.AllAg.Nephrectomy_sample hg19 TFs and others Kidney Nephrectomy sample h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.Kid.05.AllAg.Nephrectomy_sample.bed ...

  13. File list: Oth.Kid.20.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Kid.20.AllAg.Nephrectomy_sample hg19 TFs and others Kidney Nephrectomy sample h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.Kid.20.AllAg.Nephrectomy_sample.bed ...

  14. Is simple nephrectomy truly simple? Comparison with the radical alternative.

    Science.gov (United States)

    Connolly, S S; O'Brien, M Frank; Kunni, I M; Phelan, E; Conroy, R; Thornhill, J A; Grainger, R

    2011-03-01

    The Oxford English dictionary defines the term "simple" as "easily done" and "uncomplicated". We tested the validity of this terminology in relation to open nephrectomy surgery. Retrospective review of 215 patients undergoing open, simple (n = 89) or radical (n = 126) nephrectomy in a single university-affiliated institution between 1998 and 2002. Operative time (OT), estimated blood loss (EBL), operative complications (OC) and length of stay in hospital (LOS) were analysed. Statistical analysis employed Fisher's exact test and Stata Release 8.2. Simple nephrectomy was associated with shorter OT (mean 126 vs. 144 min; p = 0.002), reduced EBL (mean 729 vs. 859 cc; p = 0.472), lower OC (9 vs. 17%; 0.087), and more brief LOS (mean 6 vs. 8 days; p < 0.001). All parameters suggest favourable outcome for the simple nephrectomy group, supporting the use of this terminology. This implies "simple" nephrectomies are truly easier to perform with less complication than their radical counterpart.

  15. Development and Validity of a Silicone Renal Tumor Model for Robotic Partial Nephrectomy Training.

    Science.gov (United States)

    Monda, Steven M; Weese, Jonathan R; Anderson, Barrett G; Vetter, Joel M; Venkatesh, Ramakrishna; Du, Kefu; Andriole, Gerald L; Figenshau, Robert S

    2018-04-01

    To provide a training tool to address the technical challenges of robot-assisted laparoscopic partial nephrectomy, we created silicone renal tumor models using 3-dimensional printed molds of a patient's kidney with a mass. In this study, we assessed the face, content, and construct validity of these models. Surgeons of different training levels completed 4 simulations on silicone renal tumor models. Participants were surveyed on the usefulness and realism of the model as a training tool. Performance was measured using operation-specific metrics, self-reported operative demands (NASA Task Load Index [NASA TLX]), and blinded expert assessment (Global Evaluative Assessment of Robotic Surgeons [GEARS]). Twenty-four participants included attending urologists, endourology fellows, urology residents, and medical students. Post-training surveys of expert participants yielded mean results of 79.2 on the realism of the model's overall feel and 90.2 on the model's overall usefulness for training. Renal artery clamp times and GEARS scores were significantly better in surgeons further in training (P ≤.005 and P ≤.025). Renal artery clamp times, preserved renal parenchyma, positive margins, NASA TLX, and GEARS scores were all found to improve across trials (P <.001, P = .025, P = .024, P ≤.020, and P ≤.006, respectively). Face, content, and construct validity were demonstrated in the use of a silicone renal tumor model in a cohort of surgeons of different training levels. Expert participants deemed the model useful and realistic. Surgeons of higher training levels performed better than less experienced surgeons in various study metrics, and improvements within individuals were observed over sequential trials. Future studies should aim to assess model predictive validity, namely, the association between model performance improvements and improvements in live surgery. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Renal mass anatomic characteristics and perioperative outcomes of laparoscopic partial nephrectomy: a critical analysis.

    Science.gov (United States)

    Tsivian, Matvey; Ulusoy, Said; Abern, Michael; Wandel, Ayelet; Sidi, A Ami; Tsivian, Alexander

    2012-10-01

    Anatomic parameters determining renal mass complexity have been used in a number of proposed scoring systems despite lack of a critical analysis of their independent contributions. We sought to assess the independent contribution of anatomic parameters on perioperative outcomes of laparoscopic partial nephrectomy (LPN). Preoperative imaging studies were reviewed for 147 consecutive patients undergoing LPN for a single renal mass. Renal mass anatomy was recorded: Size, growth pattern (endo-/meso-/exophytic), centrality (central/hilar/peripheral), anterior/posterior, lateral/medial, polar location. Multivariable models were used to determine associations of anatomic parameters with warm ischemia time (WIT), operative time (OT), estimated blood loss (EBL), intra- and postoperative complications, as well as renal function. All models were adjusted for the learning curve and relevant confounders. Median (range) tumor size was 3.3 cm (1.5-11 cm); 52% were central and 14% hilar. While 44% were exophytic, 23% and 33% were mesophytic and endophytic, respectively. Anatomic parameters did not uniformly predict perioperative outcomes. WIT was associated with tumor size (P=0.068), centrality (central, P=0.016; hilar, P=0.073), and endophytic growth pattern (P=0.017). OT was only associated with tumor size (Panatomic parameter predicted EBL. Tumor centrality increased the odds of overall and intraoperative complications, without reaching statistical significance. Postoperative renal function was not associated with any of the anatomic parameters considered after adjustment for baseline function and WIT. Learning curve, considered as a confounder, was independently associated with reduced WIT and OT as well as reduced odds of intraoperative complications. This study provides a detailed analysis of the independent impact of renal mass anatomic parameters on perioperative outcomes. Our findings suggest diverse independent contributions of the anatomic parameters to the

  17. File list: His.Kid.10.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Kid.10.AllAg.Nephrectomy_sample hg19 Histone Kidney Nephrectomy sample SRX95646...1037587,SRX1037586,SRX1037580 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.Kid.10.AllAg.Nephrectomy_sample.bed ...

  18. File list: His.Kid.05.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Kid.05.AllAg.Nephrectomy_sample hg19 Histone Kidney Nephrectomy sample SRX95646...1037579,SRX1037580,SRX1037585 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.Kid.05.AllAg.Nephrectomy_sample.bed ...

  19. File list: His.Kid.20.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Kid.20.AllAg.Nephrectomy_sample hg19 Histone Kidney Nephrectomy sample SRX95646...1037587,SRX1037580,SRX1037579 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.Kid.20.AllAg.Nephrectomy_sample.bed ...

  20. File list: His.Kid.50.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Kid.50.AllAg.Nephrectomy_sample hg19 Histone Kidney Nephrectomy sample SRX95646...X1037580,SRX1037579,SRX956473 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.Kid.50.AllAg.Nephrectomy_sample.bed ...

  1. Robotic partial nephrectomy for clinical stage T1 tumors: Experience in 42 cases

    Directory of Open Access Journals (Sweden)

    Kemal Ener

    2016-01-01

    Full Text Available The aim of this study was to evaluate outcomes of robotic partial nephrectomy (RAPN procedures. At two centers, 42 patients underwent RAPN. Radius, Exo/Endophytic, Nearness, Anterior/Posterior, Location (R.E.N.A.L. nephrometry and PADUA scores of patients were calculated by computed tomography (CT or magnetic resonance imaging (MRI. Intra- and perioperative (0–30 days complications were evaluated using modified Clavien classification. A four-arm da Vinci-S robotic surgical system was used and outcomes were evaluated retrospectively. Mean age of the patients was 52.3 ± 6.5 years. Mean tumor size was 3.1 ± 1.0 (1.4–6.6 cm. R.E.N.A.L. nephrometry and PADUA scores were 6.0 ± 1.5 and 7.5 ± 0.9, respectively. Mean surgical time was 127.7 ± 18.7 minutes and estimated blood loss was 100 ± 18.1 cc. Mean warm ischemia time was 16.0 ± 8.9 (0–30 minutes. Intraoperative complications did not develop in any patient. Median hospital stay was 3.0 (2–6 days. Except for 17 patients, hilar clamping was performed in 25 patients. Histopathology results included 34 renal cell carcinoma (22 clear cell, 7 chromophobe cell, 4 papillary cell, and 1 clear papillary cell. Oncocytoma (n = 4, adenoma (n = 1, fibroadipose tissue (n = 1, papillary epithelial hyperplasia (n = 1, and chronic pyelonephritis (n = 1 were present. Surgical margins were negative in all patients. During a median follow-up period of 15.5 ± 10.9 (3–46 months, neither local recurrence nor distant metastasis was detected. In conclusion, RAPN is a safe, minimally invasive surgical approach, with excellent surgical and oncological outcomes in T1 kidney tumors. Zero ischemia off-clamp RAPN is also safe in selected masses with the advantage of avoiding complete renal ischemia.

  2. A Literature Review of Renal Surgical Anatomy and Surgical Strategies for Partial Nephrectomy.

    Science.gov (United States)

    Klatte, Tobias; Ficarra, Vincenzo; Gratzke, Christian; Kaouk, Jihad; Kutikov, Alexander; Macchi, Veronica; Mottrie, Alexandre; Porpiglia, Francesco; Porter, James; Rogers, Craig G; Russo, Paul; Thompson, R Houston; Uzzo, Robert G; Wood, Christopher G; Gill, Inderbir S

    2015-12-01

    A detailed understanding of renal surgical anatomy is necessary to optimize preoperative planning and operative technique and provide a basis for improved outcomes. To evaluate the literature regarding pertinent surgical anatomy of the kidney and related structures, nephrometry scoring systems, and current surgical strategies for partial nephrectomy (PN). A literature review was conducted. Surgical renal anatomy fundamentally impacts PN surgery. The renal artery divides into anterior and posterior divisions, from which approximately five segmental terminal arteries originate. The renal veins are not terminal. Variations in the vascular and lymphatic channels are common; thus, concurrent lymphadenectomy is not routinely indicated during PN for cT1 renal masses in the setting of clinically negative lymph nodes. Renal-protocol contrast-enhanced computed tomography or magnetic resonance imaging is used for standard imaging. Anatomy-based nephrometry scoring systems allow standardized academic reporting of tumor characteristics and predict PN outcomes (complications, remnant function, possibly histology). Anatomy-based novel surgical approaches may reduce ischemic time during PN; these include early unclamping, segmental clamping, tumor-specific clamping (zero ischemia), and unclamped PN. Cancer cure after PN relies on complete resection, which can be achieved by thin margins. Post-PN renal function is impacted by kidney quality, remnant quantity, and ischemia type and duration. Surgical renal anatomy underpins imaging, nephrometry scoring systems, and vascular control techniques that reduce global renal ischemia and may impact post-PN function. A contemporary ideal PN excises the tumor with a thin negative margin, delicately secures the tumor bed to maximize vascularized remnant parenchyma, and minimizes global ischemia to the renal remnant with minimal complications. In this report we review renal surgical anatomy. Renal mass imaging allows detailed delineation of the

  3. Unilateral nephrectomy in a juvenile llama

    International Nuclear Information System (INIS)

    Van Hoogmoed, L.; Snyder, J.R.; Roberts, G.; Harmon, F.A.

    1997-01-01

    The purpose of this study was to describe the clinical presentation, diagnostic evaluation, and surgical management of a llama with an ectopic ureter. Nine-month-old female llama. The diagnostic evaluation included the use of computed tomography and an excretory ureterogram to confirm and identify the location of the ectopic ureter. Surgical management involved a unilateral nephrectomy. Computed tomography is a valuable asset to diagnose the presence and terminal location of an ectopic ureter in llamas, and nephrectomy appears to be a viable procedure to resolve the subsequent urinary incontinence

  4. Non-neoplastic parenchymal changes in kidney cancer and post-partial nephrectomy recovery of renal function.

    Science.gov (United States)

    Bazzi, Wassim M; Chen, Ling Y; Cordon, Billy H; Mashni, Joseph; Sjoberg, Daniel D; Bernstein, Melanie; Russo, Paul

    2015-09-01

    To explore the association of non-neoplastic parenchymal changes (nNPC) with patients' health and renal function recovery after partial nephrectomy (PN). This retrospective review identified 800 pT1a patients who underwent PN at Memorial Sloan Kettering Cancer Center from 2007 to 2012. Pathology reports were reviewed for nNPC graded as mild or severe: vascular sclerosis (VS), glomerulosclerosis (GS), and fibrosis/scarring. Correlations between nNPC and known preoperative predictors of renal function [age, sex, African-American race, estimated glomerular filtration rate (eGFR), American Society of Anesthesiologists (ASA) score, body mass index, coronary artery disease, and hypertension (HTN)] were assessed using Spearman's rank correlation (ρ). Multivariable linear regression, adjusted for the described known preoperative risk predictors, was performed to evaluate whether the parenchymal features were able to predict 6-month postoperative eGFR. In this study, 46 % of tumors had benign surrounding parenchyma. We noted statistically significant yet weak associations of VS with age (ρ = 0.19; p < 0.001), ASA (ρ = 0.09; p < 0.001), preoperative eGFR (ρ = -0.14; p < 0.001), and HTN (ρ = 0.14; p < 0.001). GS also significantly correlated with HTN, but the correlation was again small (ρ = 0.12; p < 0.001). After adjusting for known risk predictors, only GS was a significant predictor of 6-month postoperative eGFR. When compared with no GS, mild and severe GS were negatively associated with a decrease of 4.9 and 10.8 mL/min/1.73 m(2) in 6-month postoperative eGFR, respectively. Presence of VS and GS correlated with patients' baseline health, and presence of GS predicted postoperative renal function recovery.

  5. Robotic partial nephrectomy - Evaluation of the impact of case mix on the procedural learning curve.

    Science.gov (United States)

    Roman, A; Ahmed, K; Challacombe, B

    2016-05-01

    Although Robotic partial nephrectomy (RPN) is an emerging technique for the management of small renal masses, this approach is technically demanding. To date, there is limited data on the nature and progression of the learning curve in RPN. To analyse the impact of case mix on the RPN LC and to model the learning curve. The records of the first 100 RPN performed, were analysed at our institution that were carried out by a single surgeon (B.C) (June 2010-December 2013). Cases were split based on their Preoperative Aspects and Dimensions Used for an Anatomical (PADUA) score into the following groups: 6-7, 8-9 and >10. Using a split group (20 patients in each group) and incremental analysis, the mean, the curve of best fit and R(2) values were calculated for each group. Of 100 patients (F:28, M:72), the mean age was 56.4 ± 11.9 years. The number of patients in each PADUA score groups: 6-7, 8-9 and >10 were 61, 32 and 7 respectively. An increase in incidence of more complex cases throughout the cohort was evident within the 8-9 group (2010: 1 case, 2013: 16 cases). The learning process did not significantly affect the proxies used to assess surgical proficiency in this study (operative time and warm ischaemia time). Case difficulty is an important parameter that should be considered when evaluating procedural learning curves. There is not one well fitting model that can be used to model the learning curve. With increasing experience, clinicians tend to operate on more difficult cases. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  6. Unilateral pulmonary edema after laparoscopic nephrectomy

    Directory of Open Access Journals (Sweden)

    Shreepathi Krishna Achar

    2011-01-01

    Full Text Available Unilateral-dependent pulmonary edema though reported in laparoscopic donor nephrectomies, has not been reported after laparoscopic non-donor nephrectomies. A 75-kg, 61-year-old man, a diagnosed case of right renal cell carcinoma was scheduled for laparoscopic nephrectomy. After establishing general anesthesia, the patient was positioned in the left-sided modified kidney (flank position. During the 5.75-hour procedure, he was hemodynamically stable except for a transient drop in blood pressure immediately after positioning. Intra-abdominal pressure was maintained less than 15 mmHg throughout the procedure. Blood loss was approximately 50 mL and urine output was 100 mL in the first hour followed by a total of 20 mL in the next 4.75 hours. Total fluid received during the procedure included 1.5 L of Ringer′s lactate and 1.0 L of 6% hydroxyethyl starch. After an uneventful procedure he developed respiratory distress in the postoperative period with a radiological evidence of dependent lung edema. Clinical and radiological improvement followed noninvasive ventilation, intravenous diuretics and oxygen therapy.

  7. The perioperative outcomes between renal hilar and non-hilar tumors following robotic-assisted partial nephrectomy (RAPN).

    Science.gov (United States)

    Lu, Shih-Yen; Chung, Hsiao-Jen; Huang, Eric Yi-Hsiu; Lin, Tzu-Pin; Lin, Alex T L

    2018-03-15

    The aim of this study was to compare the perioperative outcomes between renal hilar tumors and non-hilar tumors after robotic-assisted partial nephrectomy (RAPN). A retrospective review of consecutive patients who underwent RAPN from December 2009 to September 2015 at our institution was recruited. Perioperative outcomes including demographic characteristics, perioperative, pathological and renal function outcomes were compared between the hilar group (n = 30) and non-hilar group (n = 170). In characteristics, hilar group was younger (52.4 vs. 58 years, p = 0.04) and had less body mass index (23.7 vs. 25.4 kg/m 2 , p = 0.018). Hilar group had larger tumor size (4.8 vs. 3.7 cm, p = 0.009), higher Preoperative Aspects and Dimensions Used for an Anatomical (PADUA) score (10.7 vs. 8.5, p Hilar tumor was associated with longer operative time (293.6 vs. 240.5 min, p = 0.001) and warm ischemia time (39.9 vs. 21.8 min, p hilar tumor patients had no difference of the change of creatinine and estimated glomerular filtration rate (eGFR) at postoperative 6 and 12 month as compared with non-hilar tumor patients. For renal hilar tumor, RAPN could provide acceptable results of perioperative, pathological and renal function outcome as compared with non-hilar tumor group. Thus RAPN is a safe and effective nephron-sparing surgery technique for renal hilar tumors. Copyright © 2018. Published by Elsevier Taiwan LLC.

  8. An audit of nephrectomy by general surgeons | Mungadi | Nigerian ...

    African Journals Online (AJOL)

    ... nephrectomy for non functioning hydronephrotic kidneys. The outcome in the treatment of the congenital renal anomalies, malignant and trauma to the kidney was not satisfactory suggesting the trained urologist will be better equipped to sort things out. Keywords: audit, nephrectomy, general surgeons. Nigerian Journal of ...

  9. File list: NoD.Kid.10.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Kid.10.AllAg.Nephrectomy_sample hg19 No description Kidney Nephrectomy sample h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/NoD.Kid.10.AllAg.Nephrectomy_sample.bed ...

  10. File list: NoD.Kid.05.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Kid.05.AllAg.Nephrectomy_sample hg19 No description Kidney Nephrectomy sample h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/NoD.Kid.05.AllAg.Nephrectomy_sample.bed ...

  11. File list: NoD.Kid.20.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.Kid.20.AllAg.Nephrectomy_sample hg19 No description Kidney Nephrectomy sample h...ttp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/NoD.Kid.20.AllAg.Nephrectomy_sample.bed ...

  12. Single access laparoscopic nephrectomy

    Directory of Open Access Journals (Sweden)

    Jay D Raman

    2008-01-01

    Full Text Available Laparoscopic nephrectomy has assumed a central role in the management of benign and malignant kidney diseases. While laparoscopy is less morbid than open surgery, it still requires several incisions each at least 1-2 cm in length. Each incision carries morbidity risks of bleeding, hernia and/or internal organ damage, and incrementally decreases cosmesis. An alternative to conventional laparoscopy is single access or keyhole surgery, which utilizes magnetic anchoring and guidance system (MAGS technology or articulating laparoscopic instruments. These technical innovations obviate the need to externally space trocars for triangulation, thus allowing for the creation of a small, solitary portal of entry into the abdomen. Laboratory and early clinical series demonstrate feasibility as well as safe and successful completion of keyhole nephrectomy. Future work is necessary to improve existing instrumentation, increase clinical experience, assess benefits of this surgical approach, and explore other potential applications for this technique.

  13. Fast access and early ligation of the renal pedicle significantly facilitates retroperitoneal laparoscopic radical nephrectomy procedures: modified laparoscopic radical nephrectomy

    Directory of Open Access Journals (Sweden)

    Yang Qing

    2013-01-01

    Full Text Available Abstract Background The objective of this study was to develop a modified retroperitoneal laparoscopic nephrectomy and compare its results with the previous technique. Methods One hundred retroperitoneal laparoscopic nephrectomies were performed from February 2007 to October 2011. The previous technique was performed in 60 cases (Group 1. The modified technique (n = 40 included fast access to the renal pedicle according to several anatomic landmarks and early ligation of renal vessels (Group 2. The mean operation time, mean blood loss, duration of hospital stay conversion rate and complication rate were compared between the groups. Results No significant differences were detected regarding mean patient age, mean body mass index, and tumor size between the two groups (P >0.05. The mean operation time was 59.5 ± 20.0 and 39.5 ± 17.5 minutes, respectively, in Groups 1 and 2 (P P P >0.05. Conclusions Early ligature using fast access to the renal vessels during retroperitoneal laparoscopic radical nephrectomy contributed to less operation time and intraoperative blood loss compared with the previous technique. In addition, the modified technique permits the procedure to be performed following the principles of open radical nephrectomy.

  14. Renal blood flow using arterial spin labelling MRI and calculated filtration fraction in healthy adult kidney donors Pre-nephrectomy and post-nephrectomy.

    Science.gov (United States)

    Cutajar, Marica; Hilton, Rachel; Olsburgh, Jonathon; Marks, Stephen D; Thomas, David L; Banks, Tina; Clark, Christopher A; Gordon, Isky

    2015-08-01

    Renal plasma flow (RPF) (derived from renal blood flow, RBF) and glomerular filtration rate (GFR) allow the determination of the filtration fraction (FF), which may have a role as a non-invasive renal biomarker. This is a hypothesis-generating pilot study assessing the effect of nephrectomy on renal function in healthy kidney donors. Eight living kidney donors underwent arterial spin labelling (ASL) magnetic resonance imaging (MRI) and GFR measurement prior to and 1 year after nephrectomy. Chromium-51 labelled ethylenediamine tetraacetic acid ((51)Cr-EDTA) with multi-blood sampling was undertaken and GFR calculated. The RBF and GFR obtained were used to calculate FF. All donors showed an increase in single kidney GFR of 24 - 75 %, and all but two showed an increase in FF (-7 to +52 %) after nephrectomy. The increase in RBF, and hence RPF, post-nephrectomy was not as great as the increase in GFR in seven out of eight donors. As with any pilot study, the small number of donors and their relatively narrow age range are potential limiting factors. The ability to measure RBF, and hence RPF, non-invasively, coupled with GFR measurement, allows calculation of FF, a biomarker that might provide a sensitive indicator of loss of renal reserve in potential donors. • Non-invasive MRI measured renal blood flow and calculated renal plasma flow. • Effect of nephrectomy on blood flow and filtration in donors is presented. • Calculated filtration fraction may be a useful new kidney biomarker.

  15. Nonfunctioning Renal Allograft Embolization as an Alternative to Graft Nephrectomy: Report on Seven Years' Experience

    International Nuclear Information System (INIS)

    Atar, Eli; Belenky, Alexander; Neuman-Levin, Margalit; Yussim, A.; Bar-Nathan, Nathan; Bachar, Gil N.

    2003-01-01

    Purpose: Graft nephrectomy is the treatment of choice in patients with graft intolerance syndrome, but it is associated with high morbidity and mortality rates. Renal vascular embolization has been suggested as a possible alternative. The aim of this study was to evaluate the efficacy and safety of arterial embolization of these nonfunctioning transplanted kidneys. Methods: Twenty-six transplanted kidneys in 25 patients with irreversible renal graft rejection and graft intolerance who underwent arterial embolization at our center from August 1994 to April 2001 we reanalyzed for procedural success and long-term outcome. Embolization was performed with absolute alcohol or with polyvinyl alcohol (Ivalon) and coils. Results: Twenty-four of the 26 (92%) procedures were technically successful, but in one patient only partial occlusion of one of two renal arteries was achieved, and in another the renal artery was already completely occluded. There were two major complications: emphysematous pyelonephritis necessitating nephrectomy and groin abscess that was drained. Follow-up ranged from 8 to 84 months. Clinical success was achieved in 24 of the 26 procedures(92%), and only in one patient did embolization fail to relieve the symptoms, and nephrectomy was performed 3 months later. Conclusion: Renal vascular embolization is a simple, safe and effective technique for the treatment of nonfunctioning renal allografts associated with graft intolerance syndrome. We suggest that it be considered the treatment of choice

  16. File list: InP.Kid.10.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Kid.10.AllAg.Nephrectomy_sample hg19 Input control Kidney Nephrectomy sample SR...90,SRX1037589,SRX1037588,SRX1037582 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.Kid.10.AllAg.Nephrectomy_sample.bed ...

  17. File list: InP.Kid.50.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Kid.50.AllAg.Nephrectomy_sample hg19 Input control Kidney Nephrectomy sample SR...84,SRX1037589,SRX1037590,SRX1037583 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.Kid.50.AllAg.Nephrectomy_sample.bed ...

  18. File list: InP.Kid.05.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Kid.05.AllAg.Nephrectomy_sample hg19 Input control Kidney Nephrectomy sample SR...84,SRX1037590,SRX1037588,SRX1037589 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.Kid.05.AllAg.Nephrectomy_sample.bed ...

  19. File list: InP.Kid.20.AllAg.Nephrectomy_sample [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Kid.20.AllAg.Nephrectomy_sample hg19 Input control Kidney Nephrectomy sample SR...83,SRX1037590,SRX1037588,SRX1037582 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.Kid.20.AllAg.Nephrectomy_sample.bed ...

  20. Clinical effectiveness, tolerability and cost-effectiveness of newer drugs for epilepsy in adults: a systematic review and economic evaluation.

    Science.gov (United States)

    Wilby, J; Kainth, A; Hawkins, N; Epstein, D; McIntosh, H; McDaid, C; Mason, A; Golder, S; O'Meara, S; Sculpher, M; Drummond, M; Forbes, C

    2005-04-01

    AEDs or other newer AEDs. For newer AEDs versus placebo, a trend was observed in favour of newer drugs, and there was evidence of statistically significant differences in proportion of responders favouring newer drugs. However, it was not possible to assess long-term effectiveness. Most trials were conducted in patients with partial seizures. For newer AEDs versus older drugs, there was no evidence to assess the effectiveness of LEV, LTG or OXC, and evidence for other newer drugs was limited to single studies. Trials only included patients with partial seizures and follow-up was relatively short. There was no evidence to assess effectiveness of adjunctive LEV, OXC or TPM versus other newer drugs, and there were no time to event or cognitive data. No studies assessed the effectiveness of adjunctive AEDs in the elderly or pregnant women. There was some evidence from one study (GBP versus LTG) that both drugs have some beneficial effect on behaviour in people with learning disabilities. Eighty RCTs reported the incidence of adverse events. There was no consistent or convincing evidence to draw any conclusions concerning relative safety and tolerability of newer AEDs compared with each other, older AEDs or placebo. The integrated economic analysis for monotherapy for newly diagnosed patients with partial seizures showed that older AEDs were more likely to be cost-effective, although there was considerable uncertainty in these results. The integrated analysis suggested that newer AEDs used as adjunctive therapy for refractory patients with partial seizures were more effective and more costly than continuing with existing treatment alone. Combination therapy, involving new AEDs, may be cost-effective at a threshold willingness to pay per quality-adjusted life year (QALY) greater than 20,000 pounds, depending on patients' previous treatment history. There was, again, considerable uncertainty in these results. There were few data available to determine effectiveness of

  1. The most common cause of non-functioning kidney nephrectomy: Urolithiasis

    Directory of Open Access Journals (Sweden)

    Şenol Adanur

    2014-09-01

    Full Text Available Objective: Our aim is to evaluate and present the characteristics of patients underwent nephrectomy due to nonfunctional kidney secondary to urolithiasis in our clinic. Methods:Totally 696 patients were anlyzed retrospectively who underwent nephrectomy in our clinic between January 2000 and December 2012. Etiologies and characteristics of nephrectomy applied patients due to nontumoral non-functional kidney related with urinary tract stones are evaluated. Diagnoses of the patients were confirmed by using urinary system ultrasonography, ab dominal computed tomography, intravenous urography and renal scintigraphy. Results:Nephrectomy was performed for 280 (40.2% patients due to tumor formation and for 416 (59.8% patients due to non-functional kidney of totally 696 patients.43.8% (182 of non-funtional kidney cases were resulted by upper urinary tract stones. Mean age of nephrectomy performed urolithiasis patients were 43.7±16.9 years. 53.3% (97 of patients were male and 46.7% (85 patients were female. Preoperative mean creatinine value of patients were detected 2.98±0.47 mg/dl. Renal stone local izatian was ureteropelvic junction in 81.3% (148, ureter in 14.3% (26 and renal+ureter in 4.4% (8 of the patients. 66.8% of reteropelvic junction stones were 10-30 mm in size. Conclusion: Upper urinary tract stones are primer responsible of non-functional kidney development besides forming most of the non-tumor related nephrectomies. Routine urinary system examination should be suggested to patients with a history of urolithiasis in order to prevent later probable organ losses.

  2. Laparoendoscopic pfannenstiel nephrectomy using conventional laparoscopic instruments - preliminary experience

    Directory of Open Access Journals (Sweden)

    Anibal W. Branco

    2010-12-01

    Full Text Available PURPOSE: To confirm the feasibility of the laparoendoscopic Pfannenstiel nephrectomy using conventional laparoscopic instruments. MATERIALS AND METHODS: Since March 2009, laparoscopic nephrectomy through a Pfannenstiel incision has been performed in selected patients in our service. The Veress needle was placed through the umbilicus which allowed carbon dioxide inflow. One 5 mm (or 10 mm trocar was placed at the umbilicus for the laparoscope, to guide the placement of three trocars over the Pfannenstiel incision. Additional trocars were placed as follows: a 10 mm in the midline, a 10 mm ipsilateral to the kidney to be removed (2 cm away from the middle one, and a 5 mm contralateral to the kidney to be removed (2 cm away from the middle one. The entire procedure was performed using conventional laparoscopic instruments. At the end of the surgery, trocars were removed and all three incisions were united into a single Pfannenstiel incision for specimen retrieval. RESULTS: Five nephrectomies were performed following this technique: one atrophic kidney, one kidney donation, two renal cancers and one bilateral renal atrophy. Median operative time was 100 minutes and median intraoperative blood loss was 100 cc. No intraoperative complications occurred and no patients required blood transfusion. Median length of hospital stay was 1 day (range 1 to 2 days. CONCLUSIONS: The use of the Pfannenstiel incision for laparoscopic nephrectomy seems to be feasible even when using conventional laparoscopic instruments, and can be considered a potential alternative for traditional laparoscopic nephrectomy.

  3. Open Partial Nephrectomy for High-Risk Renal Masses Is Associated with Renal Pseudoaneurysms: Assessment of a Severe Procedure-Related Complication

    Directory of Open Access Journals (Sweden)

    M. C. Kriegmair

    2015-01-01

    Full Text Available Objectives. A symptomatic renal pseudoaneurysm (RPA is a severe complication after open partial nephrectomy (OPN. The aim of our study was to assess incidence and risk factors for RPA formation. Furthermore, we present our management strategy. Patients and Methods. Clinical records of consecutive patients undergoing OPN were assessed for surgical outcome and postoperative complications. Renal masses were risk stratified for tumor complexity according to the PADUA score. Uni- and multivariate analysis for symptomatic RPAs were performed using the t-tests and logistic regression. Results. We identified 233 patients treated with OPN. Symptomatic RPAs were observed in 13 (5.6% patients, on average 14 (4–42 days after surgery. Uni- and multivariate analysis identified tumor complexity to be an independent predictor for symptomatic RPAs (p=0.004. There was a significant correlation between RPAs and transfusion and the duration of stay (p<0.001 and p=0.021. Symptomatic RPAs were diagnosed with CT scans and successfully treated with arterial embolization. Discussion. Symptomatic RPAs are not uncommon after OPN for high-risk renal masses. A high nephrometry score is a predictor for this severe complication and may enable a risk-stratified followup. RPAs can successfully be located by CT angiography, which enables targeted angiographic treatment.

  4. Laparoscopic nephrectomy: initial experience with 120 cases.

    LENUS (Irish Health Repository)

    Cheema, I A

    2010-02-01

    Laparoscopic nephrectomy for both benign and malignant diseases of kidney is increasingly being performed. We report our experience with the first 120 consecutive laparoscopic nephrectomy performed in our hospital. It is the retrospective analysis of a prospectively maintained database of 4 years period. The parameters examined included age, gender, indications, operative time, blood loss, intraoperative and post operative complications. Mean age of surgery was 59 years (rang 19-84years). The indications for surgery included solid renal masses (71 patients), non-functioning kidneys (43), and collecting system tumours (6). The mean operating time was 132 minutes (range 75-270), average blood loss was 209 ml (range 0-1090) and average hospital stay was 4.7days (range 2-20). Bleeding, bowel injury and poor progression of laparoscopic procedure were the reasons in 7 (5.8%) cases converted to open surgery. There was 1 (0.8%) perioperative mortality. Eight (6.6%) patients developed post operative complications. Laparoscopic nephrectomy has inherent benefits and may be considered an alternate therapeutic option for kidney diseases with acceptable morbidity

  5. Laparoscopic nephrectomy: initial experience with 120 cases.

    LENUS (Irish Health Repository)

    Cheema, I A

    2012-02-01

    Laparoscopic nephrectomy for both benign and malignant diseases of kidney is increasingly being performed. We report our experience with the first 120 consecutive laparoscopic nephrectomy performed in our hospital. It is the retrospective analysis of a prospectively maintained database of 4 years period. The parameters examined included age, gender, indications, operative time, blood loss, intraoperative and post operative complications. Mean age of surgery was 59 years (rang 19-84years). The indications for surgery included solid renal masses (71 patients), non-functioning kidneys (43), and collecting system tumours (6). The mean operating time was 132 minutes (range 75-270), average blood loss was 209 ml (range 0-1090) and average hospital stay was 4.7days (range 2-20). Bleeding, bowel injury and poor progression of laparoscopic procedure were the reasons in 7 (5.8%) cases converted to open surgery. There was 1 (0.8%) perioperative mortality. Eight (6.6%) patients developed post operative complications. Laparoscopic nephrectomy has inherent benefits and may be considered an alternate therapeutic option for kidney diseases with acceptable morbidity

  6. Hand-assisted right laparoscopic nephrectomy in living donor

    Directory of Open Access Journals (Sweden)

    Fernando Meyer

    2005-02-01

    Full Text Available OBJECTIVE: To assess results obtained with the authors' technique of right hand-assisted laparoscopic nephrectomy in living kidney donors. MATERIALS AND METHODS: We retrospectively analyzed 16 kidney donors who underwent hand-assisted right laparoscopic nephrectomy from February 2001 to July 2004. Among these patients, 7 were male and 9 were female, with mean age ranging between 22 and 58 years (mean 35.75. RESULTS: Surgical time ranged from 55 to 210 minutes (mean 127.81 min and warm ischemia time from 2 to 6 minutes (mean 3.78 min with mean intra-operative blood loss estimated at 90.62 mL. There was no need for conversion in any case. Discharge from hospital occurred between the 3rd and 6th days (mean 3.81. On the graft assessment, immediate diuresis was seen in 15 cases (93.75% and serum creatinine on the 7th post-operative day was 1.60 mg/dL on average. Renal vein thrombosis occurred in 1 patient (6.25% who required graft removal, and lymphocele was seen in 1 recipient (6.25%. CONCLUSION: Hand-assisted right laparoscopic nephrectomy in living donors is a safe and effective alternative to open nephrectomy. Despite a greater technical difficulty, the procedure presented low postoperative morbidity providing good morphological and functional quality of the graft on the recipient.

  7. Efficacy of virtual computerized tomography laparoscopy for retroperitoneoscopic nephrectomy

    International Nuclear Information System (INIS)

    Shigeta, Masanobu; Kadonishi, Yuichi; Yasumoto, Hiroaki; Mita, Koji; Usui, Tsuguru; Marukawa, Kazushi

    2004-01-01

    Retroperitoneoscopic nephrectomy is less invasive than open nephrectomy, and is an alternative surgical procedure for renal tumors and upper urothelial tumors. We evaluated the efficacy of virtual computerized tomography laparoscopy (VCTL) as a navigator for retroperitoneoscopic nephrectomy to ascertain the correct anatomy of the renal hilum pre-operatively under the retroperitoneoscopic view. Seventy-three kidneys with localized renal tumors (n=44), upper urothelial tumors (n=23), or benign renal disease (n=6) underwent multidetector-row CT. VCTL was carried out by the volume-rendered technique. The findings were compared with those of real retroperitoneoscopy. After the operation, each operator scored 1 to 5 in evaluating the usefulness of virtual retroperitoneoscopy (score 5 indicated very useful). The percentages of renal arteries depicted by VCTL compared with those noted during real surgery were 93% for kidneys with renal tumors, 100% for upper urothelial tumors and 83% for benign renal disease. Two renal arteries of 2 kidneys were not detected by virtual imaging. These were about 1 mm in diameter and directly branched from the aorta, however retroperitoneoscopic nephrectomy was performed uneventfully. VCTL depicted all the renal veins. The anatomy of the renal hilum seen on VCTL and real retroperitoneoscopy was identical, without the minor angle deviation caused by drawing the kidney during the operation. The average score for the usefulness of VCTL was 4.1, ranging from 3 to 5. The accurate surgical anatomy of the renal hilum could be predicted in almost all patients pre-operatively. VCTL is an excellent navigator for retroperitoneoscopic nephrectomy. (author)

  8. Hand-assisted retroperitoneoscopic versus standard laparoscopic donor nephrectomy: HARP-trial

    Directory of Open Access Journals (Sweden)

    Alwayn Ian PJ

    2010-03-01

    Full Text Available Abstract Background Transplantation is the only treatment offering long-term benefit to patients with chronic kidney failure. Live donor nephrectomy is performed on healthy individuals who do not receive direct therapeutic benefit of the procedure themselves. In order to guarantee the donor's safety, it is important to optimise the surgical approach. Recently we demonstrated the benefit of laparoscopic nephrectomy experienced by the donor. However, this method is characterised by higher in hospital costs, longer operating times and it requires a well-trained surgeon. The hand-assisted retroperitoneoscopic technique may be an alternative to a complete laparoscopic, transperitoneal approach. The peritoneum remains intact and the risk of visceral injuries is reduced. Hand-assistance results in a faster procedure and a significantly reduced operating time. The feasibility of this method has been demonstrated recently, but as to date there are no data available advocating the use of one technique above the other. Methods/design The HARP-trial is a multi-centre randomised controlled, single-blind trial. The study compares the hand-assisted retroperitoneoscopic approach with standard laparoscopic donor nephrectomy. The objective is to determine the best approach for live donor nephrectomy to optimise donor's safety and comfort while reducing donation related costs. Discussion This study will contribute to the evidence on any benefits of hand-assisted retroperitoneoscopic versus standard laparoscopic donor nephrectomy. Trial Registration Dutch Trial Register NTR1433

  9. Temporary targeted renal blood flow interruption using a reverse thermosensitive polymer to facilitate bloodless partial nephrectomy: a swine survival study.

    Science.gov (United States)

    Harty, Niall J; Laskey, Daniel H; Moinzadeh, Alireza; Flacke, Sebastian; Benn, James A; Villani, Rosanna; Kalra, Aarti; Libertino, John A; Madras, Peter N

    2012-09-01

    What's known on the subject? and What does the study add? Lumagel™ is a reverse thermosensitive polymer (RTP) that has previously been described in the literature as providing temporary vascular occlusion to allow for bloodless partial nephrectomy (PN) while maintaining blood flow to the untargeted portion of the kidney. At body temperature, Lumagel™ has the consistency of a viscous gel but upon cooling rapidly converts to a liquid state and does not reconstitute thereafter. This property has allowed for it to be used in situations requiring temporary vascular occlusion. Previous experience with similar RTPs in coronary arteries proved successful, with no detectable adverse events. We have previously described our technique for temporary vascular occlusion of the main renal artery, as well as segmental and sub-segmental renal branches, to allow for bloodless PN in either an open or minimally invasive approach. These experiments were performed in the acute setting. This study is a two-armed survival trial to assess whether this RTP is as safe as hilar clamping for bloodless PN. Surviving animals showed normal growth after using the RTP, absence of toxicity, no organ dysfunction, and no pathological changes attributable to the RTP. We conclude that Lumagel™ is as safe as conventional PN with hilar clamping, while adding the advantage of uninterrupted perfusion during renal resection. To examine whether randomly selected regions of the kidney could undergo temporary flow interruption with a reverse thermosensitive polymer (RTP), Lumagel™ (Pluromed, Inc., Woburn, MA, USA), followed by partial nephrectomy (PN), without adding risks beyond those encountered in the same procedure with the use of hilar clamping. A two-armed (RTP vs hilar clamp), 6-week swine survival study was performed. Four swine underwent PN using hilar clamps, while six underwent PN with flow interruption using the RTP. The RTP, administered angiographically, was used for intraluminal occlusion

  10. Renal blood flow using arterial spin labelling MRI and calculated filtration fraction in healthy adult kidney donors pre-nephrectomy and post-nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Cutajar, Marica; Clark, Christopher A.; Gordon, Isky [University College London, Imaging and Biophysics Unit, Institute of Child Health, London (United Kingdom); Hilton, Rachel; Olsburgh, Jonathon [Renal Unit, Guy' s and St Thomas' NHS Foundation Trust, London (United Kingdom); Marks, Stephen D. [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Paediatric Nephrology, London (United Kingdom); Thomas, David L. [University College London, Department of Brain Repair and Rehabilitation, Institute of Neurology, London (United Kingdom); Banks, Tina [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Radiology, London (United Kingdom)

    2015-08-15

    Renal plasma flow (RPF) (derived from renal blood flow, RBF) and glomerular filtration rate (GFR) allow the determination of the filtration fraction (FF), which may have a role as a non-invasive renal biomarker. This is a hypothesis-generating pilot study assessing the effect of nephrectomy on renal function in healthy kidney donors. Eight living kidney donors underwent arterial spin labelling (ASL) magnetic resonance imaging (MRI) and GFR measurement prior to and 1 year after nephrectomy. Chromium-51 labelled ethylenediamine tetraacetic acid ({sup 51}Cr-EDTA) with multi-blood sampling was undertaken and GFR calculated. The RBF and GFR obtained were used to calculate FF. All donors showed an increase in single kidney GFR of 24 - 75 %, and all but two showed an increase in FF (-7 to +52 %) after nephrectomy. The increase in RBF, and hence RPF, post-nephrectomy was not as great as the increase in GFR in seven out of eight donors. As with any pilot study, the small number of donors and their relatively narrow age range are potential limiting factors. The ability to measure RBF, and hence RPF, non-invasively, coupled with GFR measurement, allows calculation of FF, a biomarker that might provide a sensitive indicator of loss of renal reserve in potential donors. (orig.)

  11. Renal blood flow using arterial spin labelling MRI and calculated filtration fraction in healthy adult kidney donors pre-nephrectomy and post-nephrectomy

    International Nuclear Information System (INIS)

    Cutajar, Marica; Clark, Christopher A.; Gordon, Isky; Hilton, Rachel; Olsburgh, Jonathon; Marks, Stephen D.; Thomas, David L.; Banks, Tina

    2015-01-01

    Renal plasma flow (RPF) (derived from renal blood flow, RBF) and glomerular filtration rate (GFR) allow the determination of the filtration fraction (FF), which may have a role as a non-invasive renal biomarker. This is a hypothesis-generating pilot study assessing the effect of nephrectomy on renal function in healthy kidney donors. Eight living kidney donors underwent arterial spin labelling (ASL) magnetic resonance imaging (MRI) and GFR measurement prior to and 1 year after nephrectomy. Chromium-51 labelled ethylenediamine tetraacetic acid ( 51 Cr-EDTA) with multi-blood sampling was undertaken and GFR calculated. The RBF and GFR obtained were used to calculate FF. All donors showed an increase in single kidney GFR of 24 - 75 %, and all but two showed an increase in FF (-7 to +52 %) after nephrectomy. The increase in RBF, and hence RPF, post-nephrectomy was not as great as the increase in GFR in seven out of eight donors. As with any pilot study, the small number of donors and their relatively narrow age range are potential limiting factors. The ability to measure RBF, and hence RPF, non-invasively, coupled with GFR measurement, allows calculation of FF, a biomarker that might provide a sensitive indicator of loss of renal reserve in potential donors. (orig.)

  12. Laparoscopic nephrectomy: analysis of 34 patients

    Directory of Open Access Journals (Sweden)

    Domingos André Luís Alonso

    2003-01-01

    Full Text Available OBJECTIVE: To analyze the clinical experience of laparoscopic nephrectomy for benign and malignant diseases at a university hospital. METHODS: From February 2000 to March 2003, 34 patients (14 men and 20 women underwent transperitoneal laparoscopic total nephrectomy at the Hospital das Clinicas - FMRP-USP: 28 (82.3% patients had benign diseases and 6 (17.7% malignant neoplasias. Benign diseases were represented by: urinary stones (N-9, 32.1%, chronic pyelonephritis (N-8, 28.6%, vesicoureteral reflux (N-4, 14.3%, ureteropelvic obstruction (N-3, 10.7%, multicystic kidney (N-2, 7.1% and pyonephrosis (N-2, 7.1%. Patients age range was 2-79 years (mean - 35,1 years. RESULTS: In 32/34 patients the procedures were accomplished successfully. In 2 (5.8% cases of pyonephrosis, open conversion was necessary due to perinephric abscess and difficulties in dissection of renal hilum. Two patients had intraoperative complications (1 duodenum serous laceration an 1 vascular lesion of renal hilum, but both were managed laparoscopically. Two (5.8% post operative complications (1 delayed bleeding and 1 pancreatic fistula required open surgical exploration. The mean time of hospital stay was 58h (18 to 240h. CONCLUSION: Laparoscopic nephrectomy proved to be a method safe and associated with a low rate of morbidity, shorter hospital stay and no casualties.

  13. Comparison between magnetic anchoring and guidance system camera-assisted laparoendoscopic single-site surgery nephrectomy and conventional laparoendoscopic single-site surgery nephrectomy in a porcine model: focus on ergonomics and workload profiles.

    Science.gov (United States)

    Han, Woong Kyu; Tan, Yung K; Olweny, Ephrem O; Yin, Gang; Liu, Zhuo-Wei; Faddegon, Stephen; Scott, Daniel J; Cadeddu, Jeffrey A

    2013-04-01

    To compare surgeon-assessed ergonomic and workload demands of magnetic anchoring and guidance system (MAGS) laparoendoscopic single-site surgery (LESS) nephrectomy with conventional LESS nephrectomy in a porcine model. Participants included two expert and five novice surgeons who each performed bilateral LESS nephrectomy in two nonsurvival animals using either the MAGS camera or conventional laparoscope. Task difficulty and workload demands of the surgeon and camera driver were assessed using the validated National Aeronautics and Space Administration Task Load Index (NASA-TLX) questionnaire. Surgeons were also asked to score 6 parameters on a Likert scale (range 1=low/easy to 5=high/hard): procedure-associated workload, ergonomics, technical challenge, visualization, accidental events, and instrument handling. Each step of the nephrectomy was also timed and instrument clashing was quantified. Scores for each parameter on the Likert scale were significantly lower for MAGS-LESS nephrectomy. Mean number of internal and external clashes were significantly lower for the MAGS camera (pNASA-TLX workload ratings by the surgeon and camera driver showed that MAGS resulted in a significantly lower workload than the conventional laparoscope during LESS nephrectomy (p<0.05). The use of the MAGS camera during LESS nephrectomy lowers the task workload for both the surgeon and camera driver when compared to conventional laparoscope use. Subjectively, it appears to also improve surgeons' impressions of ergonomics and technical challenge. Pending approval for clinical use, further evaluation in the clinical setting is warranted.

  14. Compensatory renal hypertrophia in patients undergoing unilateral nephrectomy

    DEFF Research Database (Denmark)

    Mogensen, P; Munck, O; Tonnesen, K H

    1977-01-01

    Estimations of the residual glomerular filtration rate (GFR) were made from renography and GFR measurements before unilateral nephrectomy in 28 patients aged 42-77 years. The GFR was measured one week and three months after the operation and comparisons were made between the function of the remai......Estimations of the residual glomerular filtration rate (GFR) were made from renography and GFR measurements before unilateral nephrectomy in 28 patients aged 42-77 years. The GFR was measured one week and three months after the operation and comparisons were made between the function...

  15. Protective response in renal transplantation: no clinical or molecular differences between open and laparoscopic donor nephrectomy

    Directory of Open Access Journals (Sweden)

    Christiano Machado

    2013-04-01

    Full Text Available OBJECTIVE: Prolonged warm ischemia time and increased intra-abdominal pressure caused by pneumoperitoneum during a laparoscopic donor nephrectomy could enhance renal ischemia reperfusion injury. For this reason, laparoscopic donor nephrectomy may be associated with a slower graft function recovery. However, an adequate protective response may balance the ischemia reperfusion damage. This study investigated whether laparoscopic donor nephrectomy modified the protective response of renal tissue during kidney transplantation. METHODS: Patients undergoing live renal transplantation were prospectively analyzed and divided into two groups based on the donor nephrectomy approach used: 1 the control group, recipients of open donor nephrectomy (n = 29, and 2 the study group, recipients of laparoscopic donor nephrectomy (n = 26. Graft biopsies were obtained at two time points: T-1 = after warm ischemia time and T+1 = 45 minutes after kidney reperfusion. The samples were analyzed by immunohistochemistry for the Bcl-2 and HO-1 proteins and by real-time polymerase chain reaction for the mRNA expression of Bcl-2, HO-1 and vascular endothelial growth factor. RESULTS: The area under the curve for creatinine and delayed graft function were similar in both the laparoscopic and open groups. There was no difference in the protective gene expression between the laparoscopic donor nephrectomy and open donor nephrectomy groups. The protein expression of HO-1 and Bcl-2 were similar between the open and laparoscopic groups. Furthermore, the gene expression of B-cell lymphoma 2 correlated with the warm ischemia time in the open group (p = 0.047 and that of vascular endothelial growth factor with the area under the curve for creatinine in the laparoscopic group (p = 0.01. CONCLUSION: The postoperative renal function and protective factor expression were similar between laparoscopic donor nephrectomy and open donor nephrectomy. These findings ensure

  16. The Piezo Actuator-Driven Pulsed Water Jet System for Minimizing Renal Damage after Off-Clamp Laparoscopic Partial Nephrectomy.

    Science.gov (United States)

    Kamiyama, Yoshihiro; Yamashita, Shinichi; Nakagawa, Atsuhiro; Fujii, Shinji; Mitsuzuka, Koji; Kaiho, Yasuhiro; Ito, Akihiro; Abe, Takaaki; Tominaga, Teiji; Arai, Yoichi

    2017-09-01

    In the setting of partial nephrectomy (PN) for renal cell carcinoma, postoperative renal dysfunction might be caused by surgical procedure. The aim of this study was to clarify the technical safety and renal damage after off-clamp laparoscopic PN (LPN) with a piezo actuator-driven pulsed water jet (ADPJ) system. Eight swine underwent off-clamp LPN with this surgical device, while off-clamp open PN was also performed with radio knife or soft coagulation. The length of the removed kidney was 40 mm, and the renal parenchyma was dissected until the renal calyx became clearly visible. The degree of renal degeneration from the resection surface was compared by Hematoxylin-Eosin staining and immunostaining for 1-methyladenosine, a sensitive marker for the ischemic tissue damage. The mRNA levels of neutrophil gelatinase-associated lipocalin (Ngal), a biomarker for acute kidney injury, were measured by quantitative real-time PCR. Off-clamp LPN with ADPJ system was successfully performed while preserving fine blood vessels and the renal calix with little bleeding. In contrast to other devices, the resection surface obtained with the ADPJ system showed only marginal degree of ischemic changes. Indeed, the expression level of Ngal mRNA was lower in the resection surface obtained with the ADPJ system than that with soft coagulation (p = 0.02). Furthermore, using the excised specimens of renal cell carcinoma, we measured the breaking strength at each site of the human kidney, suggesting the applicability of this ADPJ to clinical trials. In conclusion, off-clamp LPN with the ADPJ system could be safely performed with attenuated renal damage.

  17. Does robotic assistance confer an economic benefit during laparoscopic radical nephrectomy?

    Science.gov (United States)

    Yang, David Y; Monn, M Francesca; Bahler, Clinton D; Sundaram, Chandru P

    2014-09-01

    While robotic assisted radical nephrectomy is safe with outcomes and complication rates comparable to those of the pure laparoscopic approach, there is little evidence of an economic or clinical benefit. From the 2009 to 2011 Nationwide Inpatient Sample database we identified patients 18 years old or older who underwent radical nephrectomy for primary renal malignancy. Robotic assisted and laparoscopic techniques were noted. Patients treated with the open technique and those with evidence of metastatic disease were excluded from analysis. Descriptive statistics were performed using the chi-square and Mann-Whitney tests, and the Student t-test. Multiple linear regression was done to examine factors associated with increased hospital costs and charges. We identified 24,312 radical nephrectomy cases for study inclusion, of which 7,787 (32%) were performed robotically. There was no demographic difference between robotic assisted and pure laparoscopic radical nephrectomy cases. Median total charges were $47,036 vs $38,068 for robotic assisted vs laparoscopic surgery (p robotic assisted surgery were $15,149 compared to $11,735 for laparoscopic surgery (p robotic assistance conferred an estimated $4,565 and $11,267 increase in hospital costs and charges, respectively, when adjusted for adapted Charlson comorbidity index score, perioperative complications and length of stay (p Robotic assisted radical nephrectomy results in increased medical expense without improving patient morbidity. Assuming surgeon proficiency with pure laparoscopy, robotic technology should be reserved primarily for complex surgeries requiring reconstruction. Traditional laparoscopic techniques should continue to be used for routine radical nephrectomy. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Initial experience with transperitoneal laparoscopic nephrectomy in an Irish hospital setting.

    LENUS (Irish Health Repository)

    Forde, J C

    2009-08-01

    Laparoscopic nephrectomy has gained widespread acceptance as a treatment for both benign and malignant conditions and is becoming increasingly popular in Irish hospitals. We report a single surgeon, single centre experience with 20 consecutive laparoscopic nephrectomies comparing them to 20 open cases performed prior to the establishment of a laparoscopic service.

  19. The Use of Newer High Translucency Zirconia in Aesthetic Zone

    Directory of Open Access Journals (Sweden)

    Zishan Dangra

    2014-01-01

    Full Text Available Loss of anterior tooth causes aesthetic and functional disharmony. Although no restorative material can approach the appearance of intact tooth enamel, glass ceramic, at the increased risk of brittle fracture, can mimic original tooth color better than the other restorative options. The newest zirconia material comes with unparalleled individualization in aesthetics and optimal physical properties. One of the basic principles of tooth preparation is conservation of tooth structure. This clinical report describes the replacement of maxillary and mandibular incisor with latest generation zirconia adhesive fixed partial denture. The authors have achieved unmatched aesthetics with newer high translucency zirconia.

  20. Risk reduction strategies in laparoscopic donor nephrectomy: A comparative study

    Directory of Open Access Journals (Sweden)

    T Manohar

    2006-01-01

    Full Text Available OBJECTIVES: As the advancements, modifications and standardization of laparoscopy are taking place, there is a need for the reduction in morbidity associated with laparoscopic live donor nephrectomy. This study was performed to determine and reconfirm the advantages of laparoscopic donor nephrectomy over its open counterpart. MATERIALS AND METHODS: Two hundred open live donor nephrectomy (ODN cases were compared to 264 cases of laparoscopic live donor nephrectomy (LDN. Pretransplant functional and radiological evaluation was done routinely by excretory urogram and renal arteriography. In case of vascular variations, CT angiography was preferred. Open cases were done by conventional method and laparoscopic group underwent certain technical and surgical modifications, including meticulous planning for the port placement. Operative time, analgesia requirement, start of the orals, hospital stay, blood loss, late allograft function, incidence of rejection, complications and technical problems were analyzed. RESULTS: Operative time was 135.8 ± 43 and 165 ± 44.4 min ( P < 0.0001, requirement of analgesia was 60.5 ± 40 and 320 ± 120 mg ( P < 0.0001, hospital stay was 4 ± 0.04 and 5.7 ± 2.03 days ( P < 0.0001, warm ischemia time was 6.1 ± 2.0 and 4.1 ± 0.80 min ( P < 0.0001 and time taken for the serum creatinine to stabilize in the recipient was 4.1 ± 1.6 and 4.32 ± 1.40 days ( P =0.06 for LDN and ODN groups respectively. There was a significant reduction in the blood loss in LDN group ( P =0.0005. Overall complications were 6.81 and 14.5% and ureteric injury was seen in 0.37 and 1% in LDN and ODN respectively. CONCLUSION: Laparoscopic live donor nephrectomy can now be performed with low morbidity and mortality to both donors and recipients and is proving to be the preferred operation to open donor nephrectomy. Our continued innovations in technical modifications have made this novel operation successful.

  1. Laparoscopic nephrectomy using the harmonic scalpel.

    Science.gov (United States)

    Helal, M; Albertini, J; Lockhart, J; Albrink, M

    1997-08-01

    Laparoscopic nephrectomy is gaining popularity. Improved instrumentation is making surgery easier with fewer complications. Our first three laparoscopic nephrectomies using the Harmonic Scalpel were performed on two women and one man. The surgical indications were nonfunctioning kidneys (two left, one right) with hypertension in one patient and stone disease in two. The three patients had a mean age of 46.3 years. The average hospital stay was 4 days, the average operative time 3.7 hours, and the average blood loss 160 mL. No complications occurred. Patients resumed oral intake within 8 hours postoperatively. We found the Harmonic Scalpel easy and safe to use. It saved time, was cost effective, and was capable of easily controlling small-vessel bleeding. In conclusion, the Harmonic Scalpel could be used effectively for both dissection and bleeding control without suction or other instrumentation.

  2. Da Vinci Xi and Si platforms have equivalent perioperative outcomes during robot-assisted partial nephrectomy: preliminary experience.

    Science.gov (United States)

    Abdel Raheem, Ali; Sheikh, Abulhasan; Kim, Dae Keun; Alatawi, Atalla; Alabdulaali, Ibrahim; Han, Woong Kyu; Choi, Young Deuk; Rha, Koon Ho

    2017-03-01

    The aims of this study were to compare the perioperative outcomes of da Vinci Xi to Si during robotic-assisted partial nephrectomy (RAPN) and to discuss the feasibility of our novel port placement scheme for the da Vinci Xi platform, to overcome the existing kinetic and technical difficulties we faced with the linear port placement in patients with a small body habitus. A retrospective data analysis of patients who underwent RPN using da Vinci Xi (n = 18) was carried out. The outcomes of the Xi group were compared with the Si group (n = 18) selected using a case-matched methodology. For da Vinci Xi, we applied the universal linear port placement in 12 patients and our modified port placement in the remaining 6 patients. The Xi group had a shorter mean docking time of 17.8 ± 2.6 min compared to the Si group of 20.5 ± 2.1 min (p = 0.002); otherwise, no significant difference was present with regard to the remaining perioperative variables (p > 0.05). The modified Xi port placement had a shorter mean console time of 70.8 ± 9.7 min compared to the universal linear port placement of 89.3 ± 17.2 min (p = 0.03). Moreover, it provided a broader field of vision with excellent robotic arms movement, minimizing collisions and allowing an easier and comfortable surgical assist. Da Vinci Xi appears to be feasible and safe during RPN with similar outcomes to Si. The novel Xi port placement makes surgery easier in patients with low BMI.

  3. Laparoscopic nephrectomy in live donor

    Directory of Open Access Journals (Sweden)

    Mitre Anuar I.

    2004-01-01

    Full Text Available OBJECTIVE: To present the initial experience of videolaparoscopic nephrectomy in live renal donor. MATERIALS AND METHODS: In the period from April 2000 to August 2003, 50 left nephrectomies in live donor were performed by videolaparoscopy for transplantation. Twenty-eight patients were male (56% and 22 female (44%. Mean age was 37.2 years, and the mean body mass index (BMI was 27.1 kg/m². RESULTS: Mean surgical time was 179.5 minutes, and warm ischemia time of the graft was 3.79 minutes. The mean estimated bleeding was 141 mL. There was no need of blood transfusion or conversion to open surgery. In 42 cases (84%, the vascular portion of the graft was considered good by the recipient's surgical team and in all cases, the ureter was considered of proper size, though in one of them (2% its vascularization was considered improper. The transplanted kidneys produced urine still in the surgical room in 46 of the 50 transplantations considered. In only 2 cases opioid was required for analgesia. In average, 3.1 doses of dipyrone were used for each patient during hospital stay, and hospital discharge occurred, in average, after 3.2 days post-operatively. Two patients required re-operations and one of them evolved to death. CONCLUSIONS: The laparoscopic nephrectomy in live donor for renal transplantation is an alternative to conventional open surgery. In relation to the graft, no alteration, either anatomic or functional, was detected. Though there is already a large documentation in the international literature regarding this procedure, in our setting a prospective randomized study with the usual surgical study is still necessary in order to prove the advantages and disadvantages of the method.

  4. Laparoscopic nephrectomy in live donor

    Directory of Open Access Journals (Sweden)

    Anuar I. Mitre

    2004-02-01

    Full Text Available OBJECTIVE: To present the initial experience of videolaparoscopic nephrectomy in live renal donor. MATERIALS AND METHODS: In the period from April 2000 to August 2003, 50 left nephrectomies in live donor were performed by videolaparoscopy for transplantation. Twenty-eight patients were male (56% and 22 female (44%. Mean age was 37.2 years, and the mean body mass index (BMI was 27.1 kg/m². RESULTS: Mean surgical time was 179.5 minutes, and warm ischemia time of the graft was 3.79 minutes. The mean estimated bleeding was 141 mL. There was no need of blood transfusion or conversion to open surgery. In 42 cases (84%, the vascular portion of the graft was considered good by the recipient's surgical team and in all cases, the ureter was considered of proper size, though in one of them (2% its vascularization was considered improper. The transplanted kidneys produced urine still in the surgical room in 46 of the 50 transplantations considered. In only 2 cases opioid was required for analgesia. In average, 3.1 doses of dipyrone were used for each patient during hospital stay, and hospital discharge occurred, in average, after 3.2 days post-operatively. Two patients required re-operations and one of them evolved to death. CONCLUSIONS: The laparoscopic nephrectomy in live donor for renal transplantation is an alternative to conventional open surgery. In relation to the graft, no alteration, either anatomic or functional, was detected. Though there is already a large documentation in the international literature regarding this procedure, in our setting a prospective randomized study with the usual surgical study is still necessary in order to prove the advantages and disadvantages of the method.

  5. Retroperitoneoscopic nephrectomy in benign pathology.

    Science.gov (United States)

    Quintela, Rodrigo S; Cotta, Leonardo R; Neves, Marcelo F; Abelha, David L; Tavora, Jose E

    2006-01-01

    We report our experience with 43 retroperitoneal laparoscopic nephrectomy for benign kidney disease. All patients had a poor function from obstructive uropathology and renal atrophy. None of these patients had a previous lumbotomy. Retroperitoneoscopy was performed with 4 trocar port technique in a lateral position. The retroperitoneal space is created by using a Gaur's balloon made of sterile glove. The approach to vascular pedicle was done posteriorly and vessels were clipped by metal and Hem-o-lock (Weck Closure Systems, North Carolina, USA) clips. The sample was intact extracted in an Endo-Bag prolonging one trocar incision. Median operative time was 160 minutes and median blood loss was 200 mL. Four cases (9%) were converted to open surgery: one case due to bleeding and 3 cases due to technical difficulties regarding perirenal adherences. Most patients (39) checked out from the Hospital in day two. Four of them were left over 3 days due to wound complications. Retroperitoneoscopy offers a safe, effective and reproductive access to nephrectomy for benign pathologies.

  6. Variability of inter-observer agreement on feasibility of partial nephrectomy before and after neoadjuvant axitinib for locally advanced renal cell carcinoma (RCC): independent analysis from a phase II trial.

    Science.gov (United States)

    Karam, Jose A; Devine, Catherine E; Fellman, Bryan M; Urbauer, Diana L; Abel, E Jason; Allaf, Mohamad E; Bex, Axel; Lane, Brian R; Thompson, R Houston; Wood, Christopher G

    2016-04-01

    To evaluate how many patients could have undergone partial nephrectomy (PN) rather than radical nephrectomy (RN) before and after neoadjuvant axitinib therapy, as assessed by five independent urological oncologists, and to study the variability of inter-observer agreement. Pre- and post-systemic treatment computed tomography scans from 22 patients with clear cell renal cell carcinoma in a phase II neoadjuvant axitinib trial were reviewed by five independent urological oncologists. R.E.N.A.L. nephrometry score and κ statistics were calculated. The median R.E.N.A.L. nephrometry score changed from 11 before treatment to 10 after treatment (P = 0.002). Five tumours with moderate complexity before axitinib treatment remained moderate complexity after treatment. Of 17 tumours with high complexity before axitinib treatment, three became moderate complexity after treatment. The overall κ statistic was 0.611. Moderate-complexity κ was 0.611 vs a high-complexity κ of 0.428. Before axitinib treatment the κ was 0.550 vs 0.609 after treatment. After treatment with axitinib, all five reviewers agreed that only five patients required RN (instead of eight before treatment) and that 10 patients could now undergo PN (instead of three before treatment). The odds of PN feasibility were 22.8-times higher after treatment with axitinib. There is considerable variability in inter-observer agreement on the feasibility of PN in patients treated with neoadjuvant targeted therapy. Although more patients were candidates for PN after neoadjuvant axitinib therapy, it remains difficult to identify these patients a priori. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  7. Percutaneous Radiofrequency Ablation Versus Robotic-Assisted Partial Nephrectomy for the Treatment of Small Renal Cell Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Pantelidou, Maria [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Challacombe, Ben [King’s Health Partners, Department of Urology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); McGrath, Andrew [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Brown, Matthew [King’s Health Partners, Department of Urology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Ilyas, Shahzad; Katsanos, Konstantinos, E-mail: konstantinos.katsanos@gstt.nhs.uk; Adam, Andreas [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2016-11-15

    IntroductionThe authors compared the oncologic outcomes of radiofrequency ablation (RFA) with robotic-assisted partial nephrectomy (RPN) for the treatment of T1 stage renal cell carcinoma (RCC).Materials and methodsThis was a retrospective data analysis of a high-volume single tertiary centre. Patients were treated with RFA or RPN following multidisciplinary decision making. Only histologically proven RCCs were included. Baseline demographics were collected, and PADUA scores of tumour features were calculated to standardize baseline anatomy. Peri-operative complications, kidney function and oncological outcomes were compared.ResultsSixty-three cases were included in each group. Baseline renal function was poorer in RFA, and 16/63 RFA patients had tumours in single kidneys compared to 1/63 RPN cases (p < 0.001). Length of stay was shorter in RFA (1 vs. 3 days, p < 0.0001). Post-procedure renal function decline at 30 days was significantly less in RFA [(−0.8) ± 9.6 vs. (−16.1) ± 19.5 mls/min/1.73 m{sup 2}; p < 0.0001]. More minor complications were recorded in RPN (10/63 vs. 4/63, p = 0.15), but local recurrence was numerically higher in RFA (6/63 vs. 1/63, p = 0.11). Disease-free survival (DFS) was not significantly different (adjusted HR = 0.6, 95 % Cl 0.1–3.7; p = 0.60). Increasing tumour size was an independent predictor of local recurrence (adjusted HR = 1.7; 95 % Cl 1.1–2.6 per cm; p = 0.02).ConclusionsBoth RPN and RFA offer very good oncological outcomes for the treatment of T1 RCC with low peri-operative morbidity and similar oncologic outcomes. RFA demonstrated fewer peri-operative complications and better preservation of renal function, whereas RPN had an insignificantly lower local recurrence rate. RFA should be offered alongside RPN for selected cases.

  8. Percutaneous Radiofrequency Ablation Versus Robotic-Assisted Partial Nephrectomy for the Treatment of Small Renal Cell Carcinoma

    International Nuclear Information System (INIS)

    Pantelidou, Maria; Challacombe, Ben; McGrath, Andrew; Brown, Matthew; Ilyas, Shahzad; Katsanos, Konstantinos; Adam, Andreas

    2016-01-01

    IntroductionThe authors compared the oncologic outcomes of radiofrequency ablation (RFA) with robotic-assisted partial nephrectomy (RPN) for the treatment of T1 stage renal cell carcinoma (RCC).Materials and methodsThis was a retrospective data analysis of a high-volume single tertiary centre. Patients were treated with RFA or RPN following multidisciplinary decision making. Only histologically proven RCCs were included. Baseline demographics were collected, and PADUA scores of tumour features were calculated to standardize baseline anatomy. Peri-operative complications, kidney function and oncological outcomes were compared.ResultsSixty-three cases were included in each group. Baseline renal function was poorer in RFA, and 16/63 RFA patients had tumours in single kidneys compared to 1/63 RPN cases (p < 0.001). Length of stay was shorter in RFA (1 vs. 3 days, p < 0.0001). Post-procedure renal function decline at 30 days was significantly less in RFA [(−0.8) ± 9.6 vs. (−16.1) ± 19.5 mls/min/1.73 m"2; p < 0.0001]. More minor complications were recorded in RPN (10/63 vs. 4/63, p = 0.15), but local recurrence was numerically higher in RFA (6/63 vs. 1/63, p = 0.11). Disease-free survival (DFS) was not significantly different (adjusted HR = 0.6, 95 % Cl 0.1–3.7; p = 0.60). Increasing tumour size was an independent predictor of local recurrence (adjusted HR = 1.7; 95 % Cl 1.1–2.6 per cm; p = 0.02).ConclusionsBoth RPN and RFA offer very good oncological outcomes for the treatment of T1 RCC with low peri-operative morbidity and similar oncologic outcomes. RFA demonstrated fewer peri-operative complications and better preservation of renal function, whereas RPN had an insignificantly lower local recurrence rate. RFA should be offered alongside RPN for selected cases.

  9. Palliative nephrectomy until targeted therapy of disseminated kidney cancer patients

    Directory of Open Access Journals (Sweden)

    A. V. Klimov

    2015-01-01

    Full Text Available Objective: to assess the role of palliative nephrectomy in disseminated kidney cancer patients planned to undergo targeted antiangiogenic treatment.Subjects and methods. The investigation included data on 83 patients with T1-4N0 / +M1 disseminated renal cell carcinoma (RCC who had received at least 2 targeted therapy cycles in 2009 to 2011. In 48 (57.8 % patients, the treatment was preceded by palliative nephrectomy that was not carried out in 35 (42.2 %. Before starting targeted therapy, all the cases were confirmed to be diagnosed with clear cell RCC, with a sarcomatoid component being in 7 (8.4 % patients. The median follow-up of all the patients was 21 (12–36 months.Results. The unremoved affected kidney in disseminated kidney cancer patients receiving targeted antiangiogenic therapy is an independent factor for the poor prognosis of progression-free (odds ratio (OR, 2.4; 95 % confidence interval (CI, 1.2–4.7 and overall (OR, 2.8; 95 % CI, 1.3–6.3 survival. Palliative nephrectomy does not improve the prognosis in patients with a low somatic status, the N+ category, and metastases into the bones and nonregional lymph nodes.Conclusion. Palliative nephrectomy in the selected patients with disseminated kidney cancer on targeted antiangiogenic therapy increases progression-free and overall survival.

  10. Laparoscopic partial nephrectomy in rats Nefrectomia parcial laparoscópica em ratos

    Directory of Open Access Journals (Sweden)

    Fernando Meyer

    2007-04-01

    Full Text Available PURPOSE: To establish an experimental model of laparoscopic partial nephrectomy (LPN in rats and to analyze morphological alterations in the renal parenchyma utilizing an electric cautery and harmonic scalpel. METHODS: Forty Wistar rats were used, divided in 2 experiments with 20 rats each: experiment I, LPN was performed with an electric cautery and the rats were subdivided into groups A and B; experiment II, LPN was performed with a harmonic scalpel and they were subdivided into groups C and D. The animals in groups A and C were sacrificed shortly after surgery and the remnant kidney was removed to study the following variables: necroses and degeneration. In groups B and D a laparatomy was performed for retrieval of the remnant kidney on the 14th day after surgery to analyze fibrous scarring. RESULTS: For the variables necroses and fibrous scarring, the electric cautery creates, on average, greater width than that produced by the harmonic scalpel (p=0.0002 and p=0.0068 respectively. Regarding the variable of degeneration, we found no significant difference between the two types of scalpels (p=0.1267. CONCLUSIONS: LPN in rats is an adequate and feasible experimental model. The electric cautery caused greater damage to remnant renal tissue when compared to harmonic scalpel.OBJETIVO: Estabelecer um modelo experimental de nefrectomia parcial laparoscópica (NPL em ratos e analisar as alterações morfológicas no parênquima renal utilizando-se bisturi elétrico e harmônico. MÉTODOS: Foram utilizados 40 ratos Wistar, distribuídos em dois experimentos com 20 ratos cada: experimento I, NPL utilizando-se de bisturi elétrico e subdividindo-se os ratos em grupos A e B; experimento II, NPL realizada com bisturi harmônico e subdividindo-se os ratos em grupos C e D. Os animais dos grupos A e C foram sacrificados após a cirurgia para a remoção do rim operado e estudo das seguintes variáveis: necrose e degeneração. Nos grupos B e D a laparotomia

  11. Surgical treatment of metachronous metastases in different organs following radical nephrectomy

    Directory of Open Access Journals (Sweden)

    Carlos M. N. de Jesus

    2003-06-01

    Full Text Available Renal clear cell carcinoma (RCCC is a neoplasia resistant to radio and chemotherapy, with surgical treatment being the procedure that is recognized for its curative treatment. This case report demonstrates the success of an aggressive surgical treatment for consecutive and late metachronous metastases following radical nephrectomy. CASE REPORT: Asymptomatic 50-year old man. During a routine examination, an incidental mass was found by renal ultrasonography. He underwent right radical nephrectomy due to RCCC in June 1992. During the follow-up metastases were evidenced in cerebellum on the seventh year, and in left lung and pancreas on the eighth year following the radical nephrectomy, with all of them successfully treated by surgical excision. COMMENTS: The surgical excision of consecutive and late metachronous metastases in different organs arising from RCCC is feasible, being a good therapeutic alternative in selected cases.

  12. Renal pelvic anatomy is associated with incidence, grade, and need for intervention for urine leak following partial nephrectomy.

    Science.gov (United States)

    Tomaszewski, Jeffrey J; Cung, Bic; Smaldone, Marc C; Mehrazin, Reza; Kutikov, Alexander; Viterbo, Rosalia; Chen, David Y T; Greenberg, Richard E; Uzzo, Robert G

    2014-11-01

    Although the effect of tumor complexity on perioperative outcome measures is well established, the impact of renal pelvic anatomy on perioperative outcomes remains poorly defined. To evaluate renal pelvic anatomy as an independent predictor of urine leak in moderate- and high-complexity tumors undergoing nephron-sparing surgery. Patients undergoing open partial nephrectomy (PN) for localized RCC were stratified into intermediate- and high-complexity groups using a nephrometry score (7-9 and 10-12, respectively). A renal pelvic score (RPS) was defined by the percentage of renal pelvis contained inside the volume of the renal parenchyma. On this basis, patients were categorized as having an intraparenchymal (>50%) or extraparenchymal (renal pelvis. Characteristics of patients with and without an intraparenchymal renal pelvic anatomy were compared. Inclusion criteria were met by 255 patients undergoing PN for intermediate (73.6%) and complex (26.4%) localized renal tumors (mean size: 4.6±2.9cm). Twenty-four (9.6%) renal pelves were classified as completely intraparenchymal. Following stratification by RPS, groups differed with respect to Charlson comorbidity index, body mass index, and largest tumor size, while no differences were observed between hospital length of stay, nephrometry score, estimated blood loss, operative time, and age. Intrarenal pelvic anatomy was associated with a markedly increased risk of urine leak (75% vs 6.5%; p=0.001), secondary intervention (37.5% vs 3.9%; prenal pelvic anatomy is an uncommon anatomic variant associated with an increased rate of urine leak following PN. Elevated pressures within a small intraparenchymal renal pelvis might explain the increased risk. Preoperative imaging characteristics suggestive of increased risk for urine leak should be considered in perioperative management algorithms. Copyright © 2013. Published by Elsevier B.V.

  13. Safety and hemostatic efficacy of fibrin pad in partial nephrectomy: Results of an open-label Phase I and a randomized, standard-of-care-controlled Phase I/II study

    Directory of Open Access Journals (Sweden)

    Nativ Ofer

    2012-11-01

    Full Text Available Abstract Background Bleeding severity, anatomic location, tissue characteristics, and visibility are common challenges encountered while managing intraoperative bleeding, and conventional hemostatic measures (suture, ligature, and cautery may sometimes be ineffective or impractical. While topical absorbable hemostats (TAH are useful hemostatic adjuvants, each TAH has associated disadvantages. Methods We evaluated the safety and hemostatic efficacy of a new advanced biologic combination product―fibrin pad―to potentially address some gaps associated with TAHs. Fibrin pad was assessed as adjunctive hemostat in open partial nephrectomy in single-center, open-label, Phase I study (N = 10, and as primary hemostat in multicenter, single-blind, randomized, standard-of-care (SOC-controlled Phase I/II study (N = 7 in Israel. It was used to control mild-to-moderate bleeding in Phase I and also spurting arterial bleeding in Phase I/II study. Phase I study assessed safety and Phase I/II study, proportion of successes at 10 min following randomization, analyzed by Fisher exact tests at 5% significance level. Results Phase I (N = 10: All patients completed the study. Hemostasis was achieved within 3–4 min (average = 3.1 min of a single application in all patients. Fibrin pad was found to be safe for human use, with no product-related adverse events reported. Phase I/II (N = 7: Hemostatic success at 10 min (primary endpoint was achieved in 3/4 patients treated with fibrin pad versus 0/3 patients treated with SOC. No clinically significant change in laboratory or coagulation parameters was recorded, except a case of post-procedural hemorrhage with fibrin pad, which was considered serious and related to the fibrin pad treatment, and required re-operation. Although Data Safety Monitoring Board authorized trial continuation, the sponsor decided against proceeding toward an indication for primary treatment of severe arterial

  14. Trends in the incidence of benign pathological lesions at partial nephrectomy for presumed renal cell carcinoma in renal masses on preoperative computed tomography imaging. A single institute experience with 290 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung-Hwan; Park, Sang-Un; Rha, Koon-Ho; Choi, Young-Deuk; Hong, Sung-Joon; Yang, Seung-Choul; Mah, Sang-Yol; Chung, Byung-Ha [Health System, Yonsei Univ., Seoul (Korea, Republic of)

    2010-06-15

    The aim of this study was to determine trends in the incidence of benign lesions in patients undergoing surgery for suspicious renal masses on preoperative computed tomography scan. The records of 1065 patients who underwent open consecutive partial nephrectomy (PN) or radical nephrectomy (RN) between January 2001 and December 2008 were reviewed. Patients who underwent PN during the periods 2001-2002, 2003-2004, 2005-2006, and 2007-2008 were assigned to groups 1, 2, 3 and 4, respectively. The frequencies of benign and malignant lesions in these groups were assessed according to size and histology subtypes. The ratio of PN to RN was 12.4%, 18.3%, 24.3% and 37.2% in groups 1, 2, 3 and 4, respectively (P<0.05). The mean size of resected lesions was 2.6 cm (range 0.8-6.2 cm). Of the 290 cases, histopathology revealed benign findings in 52 (17.9%). Benign pathology was found in three of 18 cases (16.7%) in group 1, seven of 36 cases (19.4%) in group 2, 12 of 63 cases (19.0%) in group 3 and 30 of 173 cases (17.3%) in group 4. There was no significant difference in the frequency of benign histology among groups. PN, as opposed to RN, has shown a rising tendency over time. The frequency of benign pathology findings after PN for suspicious renal masses on preoperative computed tomography imaging has not decreased. Proper management should favor nephron-sparing surgery for renal lesions if such lesions can be removed satisfactorily with PN. (author)

  15. An adjuvant autologous therapeutic vaccine (HSPPC-96; vitespen) versus observation alone for patients at high risk of recurrence after nephrectomy for renal cell carcinoma: a multicentre, open-label, randomised phase III trial.

    NARCIS (Netherlands)

    Wood, C.; Srivastava, P.; Bukowski, R.; Lacombe, L.; Gorelov, A.I.; Gorelov, S.; Mulders, P.F.A.; Zielinski, H.; Hoos, A.; Teofilovici, F.; Isakov, L.; Flanigan, R.; Figlin, R.; Gupta, R; Escudier, B.

    2008-01-01

    BACKGROUND: Treatment of localised renal cell carcinoma consists of partial or radical nephrectomy. A substantial proportion of patients are at risk for recurrence because no effective adjuvant therapy exists. We investigated the use of an autologous, tumour-derived heat-shock protein (glycoprotein

  16. Comparison of donor, and early and late recipient outcomes following hand assisted and laparoscopic donor nephrectomy.

    Science.gov (United States)

    Lucas, Steven M; Liaw, Aron; Mhapsekar, Rishi; Yelfimov, Daniel; Goggins, William C; Powelson, John A; Png, Keng Siang; Sundaram, Chandru P

    2013-02-01

    While laparoscopic donor nephrectomy has encouraged living kidney donation, debate exists about the safest laparoscopic technique. We compared purely laparoscopic and hand assisted laparoscopic donor nephrectomies in terms of donor outcome, early graft function and long-term graft outcome. We reviewed the records of consecutive laparoscopic and hand assisted laparoscopic donor nephrectomies performed by a single surgeon from 2002 to 2011. Donor operative time and perioperative morbidity were compared. Early graft function for kidneys procured by each technique was evaluated by rates of delayed graft function, need for dialysis and recipient discharge creatinine. Long-term outcomes were evaluated by graft function. A total of 152 laparoscopic donor nephrectomies were compared with 116 hand assisted laparoscopic donor nephrectomies. Hand assisted procedures were more often done for the right kidney (41.1% vs 17.1%, p recipient outcomes were also similar. Delayed function occurred after 0% hand assisted vs 0.9% purely laparoscopic nephrectomies, dialysis was required in 0.9% vs 1.7% and rejection episodes developed in 9.7% vs 18.4% (p >0.05). At last followup the organ was nonfunctioning in 6.1% of hand assisted and 7.7% of purely laparoscopic cases (p >0.05). The recipient glomerular filtration rate at discharge home was similar in the 2 groups. Hand assisted laparoscopic donor nephrectomy had shorter warm ischemia time but perioperative donor morbidity and graft outcome were comparable. The choice of technique should be based on patient and surgeon preference. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Newer agents for the management of overactive bladder | Epstein ...

    African Journals Online (AJOL)

    Newer agents for the management of overactive bladder. ... that these newer agents decrease the frequency of incontinence episodes, the number ... for selection of an appropriate agent based on individual factors such as cost and tolerability.

  18. Future of newer basal insulin

    OpenAIRE

    Madhu, S. V.; Velmurugan, M.

    2013-01-01

    Basal insulin have been developed over the years. In recent times newer analogues have been added to the armanentarium for diabetes therapy. This review specifically reviews the current status of different basal insulins

  19. Comparison of renal function following donor nephrectomy versus radical nephrectomy for renal tumor

    Directory of Open Access Journals (Sweden)

    Mohamed Etafy

    2015-01-01

    Full Text Available In this study, we compared renal function in patients after donor nephrectomy (DN and radical nephrectomy (RN. We retrospectively reviewed 68 patients (mean follow-up 15 months, including 30 patients who had undergone DN and 38 patients who had undergone RN. The study was performed between April 2006 and July 2010 at a single institute. Patients were matched for age and co-morbidities (hypertension and diabetes mellitus. We calculated the estimated glomerular filtration rate (eGFR using the Modification of Diet in Renal Disease study group equation. Parameters studied included GFR (≥60 to 2.0 mg/dL, metabolic acidosis (serum bicarbonate 30 mg. There were no significant demographic differences between the two study groups. After a mean follow-up of 15 months, low eGFR (<60 mL/min/1.73 m 2 was seen in 28% and 6.7% of patients in the RN and DN groups, respectively (P = 0.03. Similarly, proteinuria was seen in 21% vs 0%, P = 0.007, and de novo elevated creatinine was seen in 13% vs 0%, respectively P = 0.04; thus the changes were greater in the RN group. Our study shows that undergoing RN had a significantly greater risk of developing renal insufficiency and proteinuria compared with age-and co-morbidity-matched patients undergoing DN. We concluded that patients undergoing RN show a significantly greater risk of developing renal insufficiency and proteinuria compared with the patients undergoing DN.

  20. Newer techniques for intravascular and intraoperative neurointerventional procedures

    International Nuclear Information System (INIS)

    Higashida, R.T.; Halbach, V.V.; Hieshima, G.B.; Yang, P.

    1987-01-01

    A videotape demonstrating newer techniques used in intravascular and intraoperative embolization procedures will be presented. The authors discuss the use of some of the newer embolic agents, real-time digital subtraction angiography, roadmapping techniques, and the use of microcatheters and steerable micro guide wires, which has greatly facilitated neurovascullar embolization procedures and enhanced patient safety. A number of actual intraoperative and intravascular cases will be shown demonstrating treatment of vascular malformations of the brain and spinal cord, carotid cavernous sinus fistulas, aneurysms and dural arteriovenous malformations. The indications for treatment, patient selection, technical preparation and newer methodologies and approaches to complex vascular lesions of the brain and spinal cord are discussed in detail

  1. Need for intraoperative ultrasound and surgical recommendation for partial nephrectomy: correlation with tumor imaging features and urologist practice patterns.

    Science.gov (United States)

    Sun, Maryellen R M; Wagner, Andrew A; San Francisco, Ignacio F; Brook, Alexander; Kavoussi, Louis; Russo, Paul; Steele, Graeme; Viterbo, Rosalia; Pedrosa, Ivan

    2012-03-01

    This study aimed to evaluate the need for intraoperative ultrasound (IOUS) and recommendation for surgical approach in the resection of renal tumors through a survey of practicing urologists, with correlation to tumor imaging features and urologist practice pattern. An institutional review board-approved retrospective review, compliant with the Health Insurance Portability and Accountability Act, of 44 renal tumors that underwent laparoscopic partial nephrectomy at the study institution was performed. The numeric component of the RENAL nephrometry score (radius [diameter], % exophytic, nearness [to collecting system/renal sinus], location) was calculated for each case using preoperative computed tomography/magnetic resonance imaging. Five anonymized images of each tumor were presented to 4 academic urologists with varying practice patterns. Reviewers independently scored each case for its need for IOUS, for recommendation of a surgical technique, and for the difficulty of the proposed surgery. The RENAL scores were as follows: RENAL 1 (low complexity, score 4-6; n = 19); RENAL 2 (moderate complexity, score 7-9; n = 23); RENAL 3 (high complexity, score 10-12; n = 2). The only RENAL score component significantly influencing need for IOUS was percentage exophytic (P = 0.00002). There was an inverse relationship between normalized and averaged need for IOUS and percentage exophytic (P recommendation of surgical method was the reviewer him/herself, with each reviewer's recommendations closely matching his/her practice pattern. Size and percentage exophytic represented the only tumor features significantly (P = 0.03) influencing surgical recommendation. There was a significant difference in the perceived need for IOUS and surgical recommendation when 4 academic urologists reviewed a series of renal masses requiring resection. Percentage exophytic correlated inversely with need for IOUS. Urologist's practice pattern and tumor size and percentage exophytic were most

  2. Retroperitoneal versus transperitoneal robotic-assisted laparoscopic partial nephrectomy: a matched-pair, bicenter analysis with cost comparison using time-driven activity-based costing.

    Science.gov (United States)

    Laviana, Aaron A; Tan, Hung-Jui; Hu, Jim C; Weizer, Alon Z; Chang, Sam S; Barocas, Daniel A

    2018-03-01

    To perform a bicenter, retrospective study of perioperative outcomes of retroperitoneal versus transperitoneal robotic-assisted laparoscopic partial nephrectomy (RALPN) and assess costs using time-driven activity-based costing (TDABC). We identified 355 consecutive patients who underwent RALPN at University of California Los Angeles and the University of Michigan during 2009-2016. We matched according to RENAL nephrometry score, date, and institution for 78 retroperitoneal versus 78 transperitoneal RALPN. Unadjusted analyses were performed using McNemar's Chi-squared or paired t test, and adjusted analyses were performed using multivariable repeated measures regression analysis. From multivariable models, predicted probabilities were derived according to approach. Cost analysis was performed using TDABC. Patients treated with retroperitoneal versus transperitoneal RALPN were similar in age (P = 0.490), sex (P = 0.715), BMI (P = 0.273), and comorbidity (P = 0.393). Most tumors were posterior or lateral in both the retroperitoneal (92.3%) and transperitoneal (85.9%) groups. Retroperitoneal RALPN was associated with shorter operative times (167.0 versus 191.1 min, P = 0.001) and length of stay (LOS) (1.8 versus 2.7 days, P factoring in disposable equipment, operative time, LOS, and personnel. In two high-volume, tertiary centers, retroperitoneal RALPN is associated with reduced operative times and shortened LOS in posterior and lateral tumors, whereas sharing similar clinicopathologic outcomes, which may translate into lower healthcare costs. Further investigation into anterior tumors is needed.

  3. Radical Nephrectomy for Primary Retroperitoneal Liposarcoma Near the Kidney has a Beneficial Effect on Disease-Free Survival.

    Science.gov (United States)

    Rhu, Jinsoo; Cho, Chan Woo; Lee, Kyo Won; Park, Hyojun; Park, Jae Berm; Choi, Yoon-La; Kim, Sung Joo

    2018-01-01

    The purpose of this study is to analyze the clinical impact of radical nephrectomy on retroperitoneal liposarcoma near the kidney. Data of patients who underwent surgery for unilateral primary retroperitoneal liposarcoma near the kidney were retrospectively collected. Patients were divided into four groups according to whether they underwent nephrectomy and combined resection of other organs. Kaplan-Meier survival analysis was used to estimate disease-free survival and overall survival. Multivariable Cox analysis was used to analyze factors related to disease-free survival and overall survival. Nephrectomy (HR = 0.260, CI = 0.078-0.873, p = 0.029) had a beneficial effect on disease-free survival, while interaction model of nephrectomy*other organ resection (HR = 4.655, CI = 1.767-12.263, p = 0.002) showed poor disease-free survival. Other organ resection was not related to disease-free survival (HR = 1.543, CI = 0.146-16.251, p = 0.718). Operation method (p = 0.007) and FNCLCC grade (p free survival. While combined organ resection without nephrectomy group (HR = 1.604, CI = 0.167-15.370, p = 0.682) and radical nephrectomy with combined organ resection group (HR = 1.309, CI = 0.448-3.825, p = 0.622) did not show significant difference in disease-free survival from the mass excision only group, radical nephrectomy without combined organ resection group (HR = 0.279, CI = 0.078-0.991, p = 0.048) showed superior disease-free survival. Radical nephrectomy of unilateral primary retroperitoneal liposarcoma near the kidney has a beneficial effect on disease-free survival.

  4. Renal artery aneurysm in hand-assisted laparoscopic donor nephrectomy: case report.

    Science.gov (United States)

    Maciel, R F; Branco, A J; Branco, A W; Guterres, J C; Silva, A E; Ramos, L B; Rost, C; Vieira, C A; Cicogna, P E S; Daudt, C A; Deboni, L M; Vieira, M A; Luz, H A; Vieira, J A

    2003-12-01

    We report a living donor who underwent laparoscopic nephrectomy using a hand-assisted device (HALD). At preoperative arteriography the donor showed a renal artery aneurysm. The patient was a 37-year-old female, 166 cm height, white, weighing 87 kg, HLA identical to the recipient. HALD was indicated due to the better visualization of renal pedicle and greater security in an obese patient. Renal artery aneurysm is a rare condition, with many possible complications. The method proved to be adequate and safe for donor nephrectomy, despite a renal artery aneurysm.

  5. Single minimum incision endoscopic radical nephrectomy for renal tumors with preoperative virtual navigation using 3D-CT volume-rendering

    Directory of Open Access Journals (Sweden)

    Shioyama Yasukazu

    2010-04-01

    Full Text Available Abstract Background Single minimum incision endoscopic surgery (MIES involves the use of a flexible high-definition laparoscope to facilitate open surgery. We reviewed our method of radical nephrectomy for renal tumors, which is single MIES combined with preoperative virtual surgery employing three-dimensional CT images reconstructed by the volume rendering method (3D-CT images in order to safely and appropriately approach the renal hilar vessels. We also assessed the usefulness of 3D-CT images. Methods Radical nephrectomy was done by single MIES via the translumbar approach in 80 consecutive patients. We performed the initial 20 MIES nephrectomies without preoperative 3D-CT images and the subsequent 60 MIES nephrectomies with preoperative 3D-CT images for evaluation of the renal hilar vessels and the relation of each tumor to the surrounding structures. On the basis of the 3D information, preoperative virtual surgery was performed with a computer. Results Single MIES nephrectomy was successful in all patients. In the 60 patients who underwent 3D-CT, the number of renal arteries and veins corresponded exactly with the preoperative 3D-CT data (100% sensitivity and 100% specificity. These 60 nephrectomies were completed with a shorter operating time and smaller blood loss than the initial 20 nephrectomies. Conclusions Single MIES radical nephrectomy combined with 3D-CT and virtual surgery achieved a shorter operating time and less blood loss, possibly due to safer and easier handling of the renal hilar vessels.

  6. Robotic-assisted single-port donor nephrectomy using the da Vinci single-site platform.

    Science.gov (United States)

    LaMattina, John C; Alvarez-Casas, Josue; Lu, Irene; Powell, Jessica M; Sultan, Samuel; Phelan, Michael W; Barth, Rolf N

    2018-02-01

    Although single-port donor nephrectomy offers improved cosmetic outcomes, technical challenges have limited its application to selected centers. Our center has performed over 400 single-port donor nephrectomies. The da Vinci single-site robotic platform was utilized in an effort to overcome the steric, visualization, ergonomic, and other technical limitations associated with the single-port approach. Food and Drug Administration device exemption was obtained. Selection criteria for kidney donation included body mass index da Vinci single-site platform. Our experience supported the safety of this approach but found that the technology added cost and complexity without tangible benefit. Development of articulating instruments, energy, and stapling devices will be necessary for increased application of robotic single-site surgery for donor nephrectomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Factors Affecting Changes in the Glomerular Filtration Rate after Unilateral Nephrectomy in Living Kidney Donors and Patients with Renal Disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hye Ok; Chae, Sun Young; Back, Sora; Moon, Dae Hyuk [University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2010-04-15

    We evaluated the factors affecting changes in the postoperative glomerular filtration rate (GFR) after unilateral nephrectomy in living kidney donors and patients with renal disease. We studied 141 subjects who underwent living donor nephrectomy for renal transplantation (n=75) or unilateral nephrectomy for renal diseases (n=66). The GFR of the individual kidney was determined by Tc-99m DTPA scintigraphy before and after nephrectomy. By performing multiple linear regression analysis, we evaluated the factors that are thought to affect changes in GFR, such as age, sex, body mass index (BMI), preoperative GFR, preoperative creatinine level, operated side, presence of diabetes mellitus (DM), presence of hypertension (HTN), and duration of follow-up. In both the donor nephrectomy and the disease nephrectomy groups, GFR increased significantly after nephrectomy (46.9{+-}8.4 to 58.1{+-}12.5 vs. 43.0{+-}9.6 to 48.6{+-}12.8 ml/min, p<0.05). In the donor nephrectomy group, age was significantly associated with change in GFR ({beta}=-0.3, P<0.005). In the disease nephrectomy group, HTN, preoperative creatinine level, and age were significantly associated with change in GFR ({beta}=-6.2, p<0.005; {beta}=-10.9, p<0.01; {beta}=-0.2, p<0.01, respectively). This compensatory change in GFR was not significantly related to sex, duration of follow-up, or operated side in either group. The compensatory change in the GFR of the remaining kidney declined with increasing age in both living kidney donors and patients with renal disease.

  8. Laparoscopic donor nephrectomy versus open donor nephrectomy: Recipient′s perspective

    Directory of Open Access Journals (Sweden)

    Tukaram E Jamale

    2012-01-01

    Full Text Available Effects of laparoscopic donor nephrectomy (LDN on graft function, especially early post-transplant, have been controversial. To assess and compare early and late graft function in kidneys procured by open and laparoscopic methods, a retrospective observational study was carried out on 37 recipients-donors who underwent LDN after introduction of this technique in February 2007 at our center, a tertiary care nephrology referral center. Demographic, immunological and intraoperative variables as well as immunosuppressive protocols and number of human leukocyte antigen (HLA mismatches were noted. Early graft function was assessed by serum creatinine on Days two, five, seven, 14 and 28 and at the time of discharge. Serum creatinine values at three months and at one year post-transplant were considered as the surrogates of late graft function. Data obtained were compared with the data from 33 randomly selected kidney transplants performed after January 2000 by the same surgical team, in whom open donor nephrectomy was used. Pearson′s chi square test, Student′s t test and Mann-Whitney U test were used for statistical analysis. Early graft function (serum creatinine on Day five 2.15 mg/dL vs 1.49 mg/dL, P = 0.027 was poorer in the LDN group. Late graft function as assessed by serum creatinine at three months (1.45 mg/dL vs 1.31 mg/dL, P = 0.335 and one year (1.56 mg/dL vs 1.34 mg/dL, P = 0.275 was equivalent in the two groups. Episodes of early acute graft dysfunction due to acute tubular necrosis were significantly higher in the LDN group (37.8% vs 12.1%, Z score 2.457, P = 0.014. Warm ischemia time was significantly prolonged in the LDN group (255 s vs 132.5 s, P = 0.002. LDN is associated with slower recovery of graft function and higher incidence of early acute graft dysfunction due to acute tubular necrosis. Late graft function at one year is however comparable.

  9. Hand-assisted robotic right donor nephrectomy in patient with total situs inversus: A case report.

    Science.gov (United States)

    Gonzalez-Heredia, Raquel; Garcia-Roca, Raquel; Benedetti, Enrico

    2016-01-01

    Total situs inversus" is an infrequent congenital condition. The robot has been already proved as a safe and attractive approach for living donor nephrectomies. We report here the first right donor nephrectomy in a patient with total situs inversus that is performed using the Da Vinci platform. Published by Elsevier Ltd.

  10. Hand-assisted robotic right donor nephrectomy in patient with total situs inversus: A case report

    Directory of Open Access Journals (Sweden)

    Raquel Gonzalez-Heredia

    2016-01-01

    Full Text Available Total situs inversus” is an infrequent congenital condition. The robot has been already proved as a safe and attractive approach for living donor nephrectomies. We report here the first right donor nephrectomy in a patient with total situs inversus that is performed using the Da Vinci platform.

  11. [Bilateral nephrectomy in patients with end-stage renal failure and chronic active pyelonephritis].

    Science.gov (United States)

    Lysenko, M A; Vtorenko, V I; Trushkin, R N; Lubennikov, A E; Sysoev, A M; Sokolov, A A

    2016-02-01

    This study analyzed the results of bilateral nephrectomy in 14 patients with end-stage renal disease (ESRD) and chronic active pyelonephritis. Seven patients had urosepsis, and 10 patients had a purulent form of pyelonephritis, which was one-sided in 7 of them. In the early postoperative period, on average, after 9.3 days, 9 patients died. Statistically significant risk factors for death were: chronic hemodialysis, long-term antibiotic therapy, and existing sepsis. Intraoperative complications and postoperative morbidity were not significantly associated with death. The study results imply the need of differentiated approach to bilateral nephrectomy in patients with ESRD and risk factors for fatal outcome. It must be performed on the strong indications since the intervention does not lead to eradication of sepsis. It is advisable to perform "preventive, sanation" bilateral nephrectomy in the "cold period" in patients at risk for developing urosepsis.

  12. Cecal Volvulus Following Laparoscopic Nephrectomy and Renal Transplantation

    Science.gov (United States)

    Ravindra, Kadiyala

    2009-01-01

    Cecal volvulus is a rare cause of bowel obstruction that carries a high mortality. Recent surgery is known to be a risk factor for the development of cecal volvulus. We present a case of cecal volvulus following laparoscopic nephrectomy and renal transplantation. PMID:20202405

  13. Augmented reality: a new tool to improve surgical accuracy during laparoscopic partial nephrectomy? Preliminary in vitro and in vivo results.

    Science.gov (United States)

    Teber, Dogu; Guven, Selcuk; Simpfendörfer, Tobias; Baumhauer, Mathias; Güven, Esref Oguz; Yencilek, Faruk; Gözen, Ali Serdar; Rassweiler, Jens

    2009-08-01

    Use of an augmented reality (AR)-based soft tissue navigation system in urologic laparoscopic surgery is an evolving technique. To evaluate a novel soft tissue navigation system developed to enhance the surgeon's perception and to provide decision-making guidance directly before initiation of kidney resection for laparoscopic partial nephrectomy (LPN). Custom-designed navigation aids, a mobile C-arm capable of cone-beam imaging, and a standard personal computer were used. The feasibility and reproducibility of inside-out tracking principles were evaluated in a porcine model with an artificially created intraparenchymal tumor in vitro. The same algorithm was then incorporated into clinical practice during LPN. Evaluation of a fully automated inside-out tracking system was repeated in exactly the same way for 10 different porcine renal units. Additionally, 10 patients underwent retroperitoneal LPNs under manual AR guidance by one surgeon. The navigation errors and image-acquisition times were determined in vitro. The mean operative time, time to locate the tumor, and positive surgical margin were assessed in vivo. The system was able to navigate and superpose the virtually created images and real-time images with an error margin of only 0.5 mm, and fully automated initial image acquisition took 40 ms. The mean operative time was 165 min (range: 135-195 min), and mean time to locate the tumor was 20 min (range: 13-27 min). None of the cases required conversion to open surgery. Definitive histology revealed tumor-free margins in all 10 cases. This novel AR tracking system proved to be functional with a reasonable margin of error and image-to-image registration time. Mounting the pre- or intraoperative imaging properties on real-time videoendoscopic images in a real-time manner will simplify and increase the precision of laparoscopic procedures.

  14. Newer approaches to opioid detoxification

    Directory of Open Access Journals (Sweden)

    Siddharth Sarkar

    2012-01-01

    Full Text Available Opioid use disorders present with distressing withdrawal symptoms at the time of detoxification. The pharmacological agents and methods currently in use for detoxification mainly include buprenorphine, methadone, and clonidine. Many other pharmacological agents have been tried for opioid detoxification. This review takes a look at the newer pharmacological options, both opioid agonists and non-agonist medications that have been utilized for detoxification. Peer reviewed articles were identified using PubMed and PsychInfo databases. The keywords included for the search were a combination of ′opioid′ and ′detoxification′ and their synonyms. All the articles published in the last 10 years were screened for. Relevant data was extracted from identified studies. Many newer pharmacological agents have been tried in detoxification of opioids. However, the quest for a safe, efficacious, cost-effective pharmacological option which requires minimal monitoring still continues. The role of non-pharmacological measures and alternative medicine needs further evaluation.

  15. Oxcarbazepine versus carbamazepine monotherapy for partial onset seizures

    NARCIS (Netherlands)

    Koch, Marcus W.; Polman, Susanne K. L.

    2009-01-01

    Background Partial onset seizures are often treated with the standard antiepileptic drug carbamazepine. Oxcarbazepine is a newer antiepileptic drug related to carbamazepine that is claimed to be better tolerated. Objectives To compare efficacy and tolerability of carbamazepine and oxcarbazepine

  16. Morphological variants of renal carcinoma in radical nephrectomy specimens

    International Nuclear Information System (INIS)

    Humera, A.; Kehar, I.

    2015-01-01

    To determine the morphological variants of Renal Cell Carcinoma (RCC) to detect the commonest histopathological type with special focus to the newly introduced entity Clear Cell Papillary Renal Cell Carcinoma (CCPRCC). Study Design: Case series. Place and Duration of Study: Department of Pathology, Basic Medical Sciences Institute, JPMC, Karachi, from January 2007 to December 2012. Methodology: Paraffin embedded blocks of 32 cases of radical nephrectomy specimens for renal mass were selected from records of Pathology Department, BMSI. Cases were excluded due to inadequate biopsies. Remaining 30 cases of renal cell carcinoma were included in study. H and E staining was done for all cases and PAS stain was employed for a few cases. All cases were reviewed under light microscope. Results: The 30 cases of renal cell carcinoma included 21 (70%) clear cell renal cell carcinoma, 03 (10%) clear cell papillary renal cell carcinoma, 02 (6.6%) papillary renal cell carcinoma and 04 (13.33%) hybrid tumors. Majority of cases (53.3%) found in age range between 40 - 60 years while 23.33% cases were found in 7th and 6.6% in 8th decade of life. While 16.66% cases were in younger age group that is between 31 - 40 years of age. Sixty percent cases of right radical nephrectomies and 40% cases of left radical nephrectomies. Conclusion: CCRCC was most common histopathologic type followed by CCPRCC, hybrid tumors and PRCC. (author)

  17. Retroperitoneoscopic live donor nephrectomy: Review of the first 50 ...

    African Journals Online (AJOL)

    but the working space in the initial stages of the operation is ... To evaluate donor safety and graft outcomes for the first 50 retroperitoneoscopic ... maintained during the early learning curve of the transition to minimalaccess donor nephrectomy ...

  18. [Robotic assisted laparoscopic living donor nephrectomy: preoperative assessment and results of 100 cases].

    Science.gov (United States)

    Laplace, B; Ladrière, M; Claudon, M; Eschwege, P; Kessler, M; Hubert, J

    2014-04-01

    To assess short term morbidity and renal function after robotic laparoscopic living donor nephrectomy. We performed a retrospective analysis of 100 consecutives patients undergoing a robotic laparoscopic living donors nephrectomy. We analyzed isotopic measure of the renal function before and 4 months after surgery, the side, the number of arteries, the blood loss, the operative time and warm ischemia time. In the outcomes, we collected the complications, the length of stay, and for the receiver, the renal function recovery time, dialysis, survival and renal function at one year. Left kidney nephrectomy was performed in 85 patients and we observed 25 multiples renal arteries. Mean estimated blood loss was 0,8 g/dL. Mean operative time and warm ischemia time were respectively 174 ± 30 and 4.8 ± 1.7 minutes. Seven complications occured, with 2 major (Clavien-Dindo System). Mean length of stay was 5.1 ± 1.9 days. Mean glomerular filtration decrease was 26% and remains stable at one year after surgery. Grafts had an immediate renal function recovery for 99%, and were all functional after one year, with mean MDRD clearance of 57 ± 14mL/min. Robotic procedure in laparoscopic living donor nephrectomy seems to guarantee low morbidity and the stability of the renal function decrease of 26%. Copyright © 2013. Published by Elsevier Masson SAS.

  19. Introduction of hand-assisted retroperitoneoscopic living donor nephrectomy at Karolinska University Hospital Huddinge.

    Science.gov (United States)

    Gjertsen, H; Sandberg, A-K A; Wadström, J; Tydén, G; Ericzon, B-G

    2006-10-01

    Living donor kidney transplantation accounts for about 50% of the total number of renal transplantations at our center. From 1999 through 2005, 75 out of 220 living donor nephrectomies were performed with a laparoscopic technique (LLDN). In June 2005, we introduced the technique of hand-assisted retroperitoneoscopic nephrectomy (HARS) for living donors. Since the introduction until the end of 2005, 11 out of 18 living donor nephrectomies (LDN) were performed with HARS. Reduced operation time was observed for the HARS group (mean, 166 minutes) compared with the LLDN (mean, 244 minutes). Two grafts showed delayed function, one in the LLND group and one in the HARS group. No major perioperative or postoperative complications were observed in the HARS group, whereas one patient who underwent LLDN developed severe pancreatitis. So far in our hands HARS is a fast and safe procedure with results comparable with open LDN. Compared to LLDN, we experienced reduced operation time together with the advantage of retroperitoneal access.

  20. The Risk of Specific Congenital Anomalies in Relation to Newer Antiepileptic Drugs

    DEFF Research Database (Denmark)

    de Jong, Josta; Garne, Ester; de Jong-van den Berg, Lolkje T.W.

    2016-01-01

    BACKGROUND: More information is needed about possible associations between the newer anti-epileptic drugs (AEDs) in the first trimester of pregnancy and specific congenital anomalies of the fetus. OBJECTIVES: We performed a literature review to find signals for potential associations between newer...... studies with pregnancies exposed to newer AEDs and detailed information on congenital anomalies. The congenital anomalies in the studies were classified according to the congenital anomaly subgroups of European Surveillance of Congenital Anomalies (EUROCAT). We compared the prevalence of specific...... and were not supported by other studies. No signals were found for the other newer AEDs, or the information was too limited to provide such a signal. CONCLUSION: In terms of associations between monotherapy with a newer AED in the first trimester of pregnancy and a specific congenital anomaly, the signals...

  1. Newer antiepileptic drugs in the treatment of status epilepticus: impact on prognosis.

    Science.gov (United States)

    Jaques, Léonore; Rossetti, Andrea O

    2012-05-01

    Newer antiepileptic drugs (AEDs) are increasingly prescribed and seem to have a comparable efficacy as the classical AEDs; however, their impact on status epilepticus (SE) prognosis has received little attention. In our prospective SE database (2006-2010), we assessed the use of older versus newer AEDs (levetiracetam, pregabalin, topiramate, lacosamide) over time and its relationship to outcome (return to clinical baseline conditions, new handicap, or death). Newer AEDs were used more often toward the end of the study period (42% of episodes versus 30%). After adjustment for SE etiology, SE severity score, and number of compounds needed to terminate SE, newer AEDs were independently related to a reduced likelihood of return to baseline (p<0.001) but not to increased mortality. These findings seem in line with recent findings on refractory epilepsy. Also, in view of the higher price of the newer AEDs, well-designed, prospective assessments analyzing the impact of newer AEDs on efficacy and tolerability in patients with SE appear mandatory. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Hilar location is an independent prognostic factor for recurrence in T1 renal cell carcinoma after nephrectomy.

    Science.gov (United States)

    Shim, Myungsun; Song, Cheryn; Park, Sejun; Kim, Aram; Choi, Seung-Kwon; Kim, Choung-Soo; Ahn, Hanjong

    2015-01-01

    We investigated the prognostic significance of tumor location at the renal hilum near the sinus structure on the recurrence in T1 renal cell carcinoma (RCC). A total of 1,818 T1 RCC patients who underwent radical (RN) or partial nephrectomy (PN) from 1997 to 2011 were retrospectively reviewed. A hilar tumor was defined as a tumor abutting the main renal artery and/or vein or its segmental branches, without invasion. We compared the recurrence-free survival (RFS) rates between hilar and nonhilar T1 RCC and analyzed predictors of RFS after nephrectomy. Patients with hilar tumors showed a poorer 5-year RFS compared with nonhilar tumors both in T1a (89.7 vs. 98.5 %, p hilar tumors were associated with lower 5-year RFS (87.6 vs. 97.2 % for RN, 78.1 vs. 98.2 % for PN, both p hilar tumor, PN was associated with poorer 5-year RFS than RN (79.5 vs. 93.0 %, p hilar location remained as an independent predictor of recurrence in both T1a and T1b tumors (both p = 0.001). Hilar tumors show a higher recurrence rate than nonhilar counterparts in T1 RCC. In T1a hilar tumors, PN demonstrated poorer RFS than RN. Potential intrinsic renal anatomical or lymphovascular structural differences as well as differences in cancer characteristics need further investigations.

  3. Laparoscopic donor nephrectomy: meeting the challenge of consumerism?

    Science.gov (United States)

    Siddins, Mark; Hart, Gabrielle; He, Bulang; Kanchanabat, Burapa; Mohan Rao, M

    2003-11-01

    Despite the increasing adoption of laparoscopic donor nephrectomy, no study has examined donor perceptions following this procedure. In particular, it has been tacitly assumed that a less invasive procedure might in itself provide a more satisfactory donor experience. The present study reviews the experience of donors undergoing laparoscopic nephrectomy, and examines the extent to which contemporary management practice addresses issues relevant to consumerism. Forty-two donors participated in a structured telephone interview, and 33 (79%) returned a written questionnaire. Coming through the survey was a strong sense of commitment to donation, and most respondents were satisfied with the experience. The main criticisms related to hotel services, the duration of the preoperative investigations, the perceived quality of nursing care on the general wards, medical communication and the duration of postoperative follow up. The self-reported time to meet recovery goals was extremely broad. Considering the nature of criticisms offered by the respondents, it is concluded that the expectations of donors as health-care consumers will only be met through modification of existing protocols.

  4. Evolution of robotic nephrectomy for living donation: from hand-assisted to totally robotic technique.

    Science.gov (United States)

    Giacomoni, Alessandro; Di Sandro, Stefano; Lauterio, Andrea; Concone, Giacomo; Mangoni, Iacopo; Mihaylov, Plamen; Tripepi, Matteo; De Carlis, Luciano

    2014-09-01

    The application of robotic-assisted surgery offers EndoWrist instruments and 3-D visualization of the operative field, which are improvements over traditional laparoscopy. The results of the few studies published so far have shown that living donor nephrectomy using the robot-assisted technique is safe, feasible, and offers advantages to patients. Since November 2009, 16 patients have undergone robotic-assisted living donor nephrectomy at our Institute. Patients were divided into two groups according to the surgical technique adopted for the procedure: Group A, hand-assisted robotic nephrectomy (eight patients); Group B, totally robotic nephrectomy (eight patients). Intra-operative bleeding was similar in the two groups (90 vs 100 mL for Group A and B, respectively). Median warm ischemia time was significantly shorter in Group A (2.3 vs 5.1 min for Group A and B, respectively, P-value = 0.05). Switching to the open procedure was never required. Median operative time was not significantly longer in Group A than Group B (275 min vs 250 min, respectively). Robotic assisted living kidney recovery is a safe and effective procedure. Considering the overall technical, clinical, and feasibility aspects of living kidney donation, we believe that the robotic assisted technique is the method of choice for surgeon's comfort and donors' safety. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Compensatory changes in the function of the remaining kidney immediately after unilateral nephrectomy in sheep

    International Nuclear Information System (INIS)

    Ziada, G.; Khalil, M.; Youseif, H.

    2009-01-01

    Live kidney donation is an established form of organ donation but carries the risk of an unnecessary surgery in a normal individual for the benefit of the recipient. Despite a number of recent studies on the renal function of long-term kidney donors, little attention has been paid to the damaging effects of compensatory hyper-filtration on renal tubular cells immediately after donor nephrectomy. The present study therefore aimed to examine the immediate changes in renal function of the remaining kidney using a sheep model of unilateral nephrectomy. We used the gamma camera-based method to measure the glomerular filtration rate and the tubular excretion values after simultaneous injection of 99m Tc-diethylene triamine pentaacetic acid and 131 I-ortho-iodohippurate tracers. Compared were the differences in the functions between the remaining left kidney immediately after clamping the right renal pedicle and the baseline values that were measured one week before unilateral nephrectomy. After radionuclide data acquisition was completed, the right kidney was removed. The mean glomerular filtration rate (GFR) increased by 52.3% from the baseline values (29.5±2.7 to 45.0±6.7 ml/min; n=40, p<0.001), while the mean effective renal plasma flow (ERPF) increased by 40% (225.5±27.8 to 357.8±38.94 ml/min; p<0.001), respectively. Mean filtration fraction was increased from 0.117 to 0.127 immediately after nephrectomy (p<0.001). We conclude that after unilateral nephrectomy the remaining kidney immediately compensates for the loss of a donated kidney by increasing glomerular filtration rate and effective renal plasma flow. (author)

  6. HAND-ASSISTED LAPAROSCOPIC DONOR NEPHRECTOMY. THE FIRST RUSSIAN EXPERIENCE

    Directory of Open Access Journals (Sweden)

    S. V. Gautier

    2010-01-01

    Full Text Available The first experience of hand-assisted laparoscopic donor nephrectomy is described in the article. A new technique of the operation and it’s results are discussed in details. Advantages of this type of the operation in comparison with open and full laparoscopic techniques are presented. 

  7. Impact of radical nephrectomy on renal functional outcome in ...

    African Journals Online (AJOL)

    H.H. Qureshi

    2015-10-09

    Oct 9, 2015 ... Abstract. Introduction: Renal cell carcinoma (RCC) accounts for 3% of all adult tumors. The mainstay of treatment of. RCCs in the past has remained radical nephrectomy (RN). Studies have found a higher cumulative incidence of development of chronic renal insufficiency in patients undergoing RN for RCC ...

  8. Graft intolerance syndrome requiring graft nephrectomy after late kidney graft failure: can it be predicted? A retrospective cohort study.

    Science.gov (United States)

    Bunthof, Kim L W; Verhoeks, Carmen M; van den Brand, Jan A J G; Hilbrands, Luuk B

    2018-02-01

    Graft nephrectomy is recommended in case of early graft failure. When the graft fails more than 3-6 months after transplantation, it is current practice to follow a wait-and-see policy. A common indication for graft removal is the graft intolerance syndrome. We aimed to create a risk prediction model for the occurrence of graft intolerance resulting in graft nephrectomy. We collected data of kidney transplantations performed in our center between 1980 and 2010 that failed at least 6 months after transplantation. We evaluated the association between baseline characteristics and the occurrence of graft nephrectomy because of graft intolerance using a competing risk regression model. Prognostic factors were included in a multivariate prediction model. In- and exclusion criteria were met in 288 cases. In 48 patients, the graft was removed because of graft intolerance. Donor age, the number of rejections, and shorter graft survival were predictive factors for graft nephrectomy because of the graft intolerance syndrome. These factors were included in a prediction rule. Using donor age, graft survival, and the number of rejections, clinicians can predict the need for graft nephrectomy with a reasonable accuracy. © 2017 Steunstichting ESOT.

  9. Newer nonconventional modes of mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Preet Mohinder Singh

    2014-01-01

    Full Text Available The conventional modes of ventilation suffer many limitations. Although they are popularly used and are well-understood, often they fail to match the patient-based requirements. Over the years, many small modifications in ventilators have been incorporated to improve patient outcome. The ventilators of newer generation respond to patient′s demands by additional feedback systems. In this review, we discuss the popular newer modes of ventilation that have been accepted in to clinical practice. Various intensive care units over the world have found these modes to improve patient ventilator synchrony, decrease ventilator days and improve patient safety. The various modes discusses in this review are: Dual control modes (volume assured pressure support, volume support, Adaptive support ventilation, proportional assist ventilation, mandatory minute ventilation, Bi-level airway pressure release ventilation, (BiPAP, neurally adjusted ventilatory assist and NeoGanesh. Their working principles with their advantages and clinical limitations are discussed in brief.

  10. Laparoscopic radical nephrectomy versus open radical nephrectomy in T1-T3 renal tumors: An outcome analysis

    Directory of Open Access Journals (Sweden)

    Arvind P Ganpule

    2008-01-01

    Full Text Available Aims: To compare laparoscopic radical nephrectomy (LRN with open radical nephrectomy (ORN in T1-T3 renal lesions. Materials and Methods: The records of 65 patients who underwent LRN between January 2002 and December 2006 were entered prospectively in a database. The patients were compared with 56 patients who had undergone ORN between January 2000 and December 2005. The two groups were comparable in terms of age, body mass index (BMI and tumor size. LRN was compared with ORN in terms of operative room time, blood loss, complications , analgesic requirement, hospital stay and start of oral intake. The oncologic efficacy was evaluated in stages T1 and T2 in terms of cancer-free and overall survival. Results: The laparoscopy group had a significantly shorter hospital stay (5.72, range 3-23 days vs. 9.18, range 4-23 days, p value: < 0.0001, analgesia requirement (175.65, range 50-550 mg vs. 236, range 0-1100 mg of tramadol, p value: < 0.03, hemoglobin decline (1.55, range 0.1 to 4.4 mg/dl vs. 2.25, range 0.2 - 7 mg/dL, p value: < 0.001 and hematocrit drop (4.83, range 0.3 - 12.9 vs. 7.06 range 2 -18, p value: < 0.0001. The majority of specimens showed renal cell carcinoma. In the laparoscopy group, 29 tumors were T1 stage, 18 were T2, while eight were T3. In the open surgery group, 25 tumors were T1, 19 were T2 and 12 were T3. The cancer-free survival rate at 24 months for ORN and LRN in T1 lesions was 91.7% and 93.15% respectively and the patient survival rate was 100% in both groups. The cancer-free survival rate at 24 months for ORN and LRN in T2 lesions was 88.9% and 94.1%, respectively and the patient survival was 100% and 94%, respectively. After LRN, there was one instance of port site metastasis, local recurrence and distant metastasis. All recurrences were distant after ORN. Conclusion: Laparoscopic radical nephrectomy has advantages in terms of shorter hospitalization and a lower analgesia requirement. It is feasible and produces effective

  11. Non-invasive monitoring of tissue oxygenation during laparoscopic donor nephrectomy

    Directory of Open Access Journals (Sweden)

    Kirk Allan D

    2008-04-01

    Full Text Available Abstract Background Standard methods for assessment of organ viability during surgery are typically limited to visual cues and tactile feedback in open surgery. However, during laparoscopic surgery, these processes are impaired. This is of particular relevance during laparoscopic renal donation, where the condition of the kidney must be optimized despite considerable manipulation. However, there is no in vivo methodology to monitor renal parenchymal oxygenation during laparoscopic surgery. Methods We have developed a method for the real time, in vivo, whole organ assessment of tissue oxygenation during laparoscopic nephrectomy to convey meaningful biological data to the surgeon during laparoscopic surgery. We apply the 3-CCD (charge coupled device camera to monitor qualitatively renal parenchymal oxygenation with potential real-time video capability. Results We have validated this methodology in a porcine model across a range of hypoxic conditions, and have then applied the method during clinical laparoscopic donor nephrectomies during clinically relevant pneumoperitoneum. 3-CCD image enhancement produces mean region of interest (ROI intensity values that can be directly correlated with blood oxygen saturation measurements (R2 > 0.96. The calculated mean ROI intensity values obtained at the beginning of the laparoscopic nephrectomy do not differ significantly from mean ROI intensity values calculated immediately before kidney removal (p > 0.05. Conclusion Here, using the 3-CCD camera, we qualitatively monitor tissue oxygenation. This means of assessing intraoperative tissue oxygenation may be a useful method to avoid unintended ischemic injury during laparoscopic surgery. Preliminary results indicate that no significant changes in renal oxygenation occur as a result of pneumoperitoneum.

  12. Retroperitoneal laparoscopic nephrectomy: the effect of the learning curve, and concentrating expertise, on operating times.

    Science.gov (United States)

    Skinner, Adrian; Maoate, Kiki; Beasley, Spencer

    2010-05-01

    Laparoscopic nephrectomy is an accepted alternative to open nephrectomy. We analyzed our first 80 procedures of laparoscopic nephrectomy to evaluate the effect of experience and configuration of service on operative times. A retrospective review of 80 consecutive children who underwent retroperitoneal laparoscopic nephrectomy or heminephrectomy during an 11-year period from 1997 at Christchurch Hospital (Christchurch, New Zealand) was conducted. Operative times, in relation to the experience of the surgeon for this procedure, were analyzed. Four surgeons, assisted by an annually rotating trainee registrar, performed the procedure in 26 girls and 54 boys (range, 8 months to 15 years). Operating times ranged from 38 to 225 minutes (mean, 104). The average operative time fell from 105 to 90 minutes. One surgeon performed 40% of the procedures and assisted with a further 55%. The operative times for all surgeons showed a tendency to reduce, but this was not marked. Most procedures were performed by two surgeons working together, although one surgeon was involved in the majority of cases. The lead surgeon is often assisted by a fellow consultant colleague. Operative times were influenced by experience, but not markedly so. The shorter operative times and minimal "learning curve," compared with other reported series, may, in part, be due to the involvement of two surgeons experienced in laparoscopy for the majority of cases.

  13. Residual kidney function after donor nephrectomy. Assessment by 99mTc-MAG3-Clearance

    International Nuclear Information System (INIS)

    Hamscho, N.; Doebert, N.; Menzel, C.; Berner, U.; Zaplatnikov, K.; Gruenwald, F.; Wilhelm, A.; Gossmann, J.; Scheuermann, E.H.

    2005-01-01

    Aim: We evaluated the long-term residual renal function after donor nephrectomy using 99m Tc-mercaptoacetyltriglycin (MAG3)-clearance. Donors, methods: Altogether 49 kidney donors were examined using 99m Tc-MAG3-clearance after nephrectomy for donation to a relative (m:f=11.38; age 55±27 years). The donors were examined 16±8 years postoperatively (1.5-26 years). 42 donors (86%) showed normal creatinine values, whereas the other seven (14%) exhibited slightly elevated levels. 20 donors were examined pre- and postoperatively and compared intraindividually. The kidney function was compared to the age adapted normal values of healthy persons with two kidneys (67-133% of age related mean). Results: After nephrectomy all donors showed a normal perfusion, good secretion, merely physiological intrarenal transit and a normal elimination from the kidneys. The 99m Tc-MAG3-clearance was 69±15% of the normal mean value of healthy carriers of two kidneys regardless of the gender. 20 donors with a preoperative examination showed a significantly reduced total renal function from 84±15% of the mean normal value preoperatively to 60±15% postoperatively (p 99m Tc-MAG3-clearance measured prior to nephrectomy and the clearance levels after nephrectomy. Also, no correlation between the preoperative 99m Tc-MAG3-clearance and the postoperative serum creatinine values could be observed. Althogether, 22% of the donors (11/49) developed arterial hypertension 10±8 years after donation (1-23 years). This corresponds to the normal age prevalence of hypertension in the carriers of two kidneys. Three donors suffered from arterial hypertension prior to the operation. Conclusion: Kidney donors with normal or slightly elevated creatinine values postoperatively show a 99m Tc-MAG3 clearance value of 69% of the mean value of healthy carriers of two kidneys. This may serve as a reference value for healthy carriers of one kidney. In our study we demonstrated a good compensation of the contralateral

  14. Renal function after unilateral nephrectomy for Wilms' tumour: the influence of radiation therapy

    International Nuclear Information System (INIS)

    Graaf, S.S.N. de; Gent, H. van; Reitsma-Bierens, W.Ch.C.; Luyk, W.H.J. van; Postma, A.; Dolsma, W.V.

    1996-01-01

    The effect of therapy on renal function after unilateral nephrectomy for Wilms' tumour was studied. In the second year following unilateral nephrectomy, glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) were estimated simultaneously by measuring 125 I-iothalamate clearance and 131 I-hippurate clearance. Of 41 evaluable patients, 29 received chemotherapy as sole treatment modality following nephrectomy (group 1); 12 patients additionally received radiation therapy to a field that included the remaining kidney (group 2). Results were expressed as standard deviation scores (z-scores). In group 1, mean z-score for GFR was -0.27 (94.6% of normal) and in group 2 mean z-score was -1.51 (72.7% of normal for two kidneys) (P = 0.022, Mann-Whitney U-test). Mean z-score for ERPF was -0.09 (97.0%) in group 1 and -1.53 (73.8%) in group 2 (P 0.039). It was concluded that the combination of chemotherapy and radiation therapy, in contrast to chemotherapy alone, negatively affects the ability of the remaining kidney to adjust its function after the loss of its counterpart. (author)

  15. Factors influencing the operating time for single-port laparoscopic radical nephrectomy: focus on the anatomy and distribution of the renal artery and vein.

    Science.gov (United States)

    Matsumoto, Kazuhiro; Miyajima, Akira; Fukumoto, Keishiro; Komatsuda, Akari; Niwa, Naoya; Hattori, Seiya; Takeda, Toshikazu; Kikuchi, Eiji; Asanuma, Hiroshi; Oya, Mototsugu

    2017-10-01

    It is considered that laparoscopic single-site surgery should be performed by specially trained surgeons because of the technical difficulty in using special instruments through limited access. We investigated suitable patients for single-port laparoscopic radical nephrectomy, focusing on the anatomy and distribution of the renal artery and vein. This retrospective study was conducted in 52 consecutive patients who underwent single-port radical nephrectomy by the transperitoneal approach. In patients undergoing right nephrectomy, a 2-mm port was added for liver retraction. We retrospectively re-evaluated all of the recorded surgical videos and preoperative computed tomography images. The pneumoperitoneum time (PT) was used as an objective index of surgical difficulty. The PT was significantly shorter for right nephrectomy than left nephrectomy (94 vs. 123 min, P = 0.004). With left nephrectomy, dissection of the spleno-renal ligament to mobilize the spleen medially required additional time. Also, the left renal vein could only be divided after securing the adrenal, gonadal and lumbar veins. In patients whose renal artery was located cranial to the renal vein, PT tended to be longer than in the other patients (131 vs. 108 min, P = 0.070). In patients with a superior renal artery, the inferior renal vein invariably covered the artery and made it difficult to ligate the renal artery via the umbilical approach at the first procedure. These findings indicate that patients undergoing right nephrectomy in whom the renal artery is not located cranial to the renal vein are suitable for single-port laparoscopic radical nephrectomy. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  16. Association of Live Donor Nephrectomy and Reversal of Renal Artery Spasm

    Directory of Open Access Journals (Sweden)

    Jalal Azmandian

    2014-01-01

    Full Text Available Background: Kidney transplantation is the best treatment option for kidney failure. Major medical progress has been made in the field of renal transplantation over the last 40 years. The surgical procedure has been standardized and the complication rate is low. Overall, the outcome of renal transplantation is excellent and has improved over time. Vascular complications after renal transplantation are the most frequent type of complication following urological complications. Renal artery spasm (RAS following manipulation of renal artery is a common problem during live donor nephrectomy (LDN. The aim of this study was to determine whether or not it is necessary to wait for reverse of RAS and resumption of urinary flow before nephrectomy. Materials and Methods: In this clinical trial 16 cases of LDN who developed RAS during surgery received intra-arterial injection of 40 mg papaverine. In 8 cases surgery continued towards nephrectomy and in other 8 cases we waited for reverse of RAS. All analyses were performed using SPSS-11. Results: In both groups urinary flow started a few minutes (Mean, 12 min after declamping of transplanted kidney and normal renal consistency and color were achieved. There was no significant difference between urinary volume during 12 h after transplantation in two groups. Conclusion: The results showed that it might not be necessary to wait for reverse of RAS before LDN. Both patient (less anesthesia complications and hospital (less expenses will benefit from this time saving.

  17. [Anesthesia experiences on laparoscopic nephrectomy with da Vinci S robotics].

    Science.gov (United States)

    Mou, Ling; Lan, Zhixun

    2015-09-01

    To summarize the clinical anesthesia experiences in 20 patients who underwent laparoscopic nephrectomy with da Vinci S robotics.
 Anesthesia data of 20 patients from Sichuan Provincial People's Hospital, who underwent laparoscopic nephrectomy with da Vinci S robotics from August 2014 to November 2014, were analyzed and summarized. The anesthesia time, operation time, CO(2) pneumoperitoneum time, PaCO(2) and PETCO(2) were recorded.
 All patients were anesthetized and underwent surgery with da Vinci S robotics. The anesthesia time was (220±14) min, the operation time was (187±11) min, and the CO(2) pneumoperitoneum time was (180±13) min. The PaCO(2) and PETCO(2) were significantly elevated at 1.5 h after operation compared with those at the baseline (before pneumoperitoneum) (Pda vinci S robotics. However, the duration of CO(2) pneumoperitoneum is significantly increased compared to that of other surgical procedures, resulting in high airway resistance and acid-base disturbance.

  18. Experience and Security of the Hand-Assisted Laparoscopic Nephrectomy of a Living Donor in a Public Health Center.

    Science.gov (United States)

    Garcia-Covarrubias, L; Prieto-Olivares, P; Bahena-Portillo, A; Cicero-Lebrija, A; Hinojosa-Heredia, H; Fernández-Lopez, L J; Almeida-Nieto, C; Visag-Castillo, V J; Carrión-Barrera, J; Castro-Ñuco, I; Pedraza-Rojas, E; Rosas-Herrera, A; García-Covarrubias, A; Fernández-Angel, D; Diliz-Perez, H S

    2018-03-01

    Hand-assisted laparoscopic nephrectomy (HALDN) is currently the procedure of choice for obtaining living donor kidneys for transplantation. In our institution, it has been the standard procedure for 5 years. Previous studies have shown the same function of the graft as that obtained by open surgery, with a lower rate of bleeding and no differences in complications. We sought to demonstrate the experience and safety of HALDN compared with open donor nephrectomy in healthy donors for kidney transplantation. A retrospective analytical observational study was conducted, reviewing the records of the living donors for kidney transplant undergoing open donor nephrectomy or HALDN in our center from March 1, 2009, to March 1, 2016. Renal function was assessed by the estimated glomerular filtration rate by the Modification of Diet in Renal Disease method before and after donation, as well as bleeding (mL), and complications (according to Clavien), performing a comparative analysis between the two techniques using parametric or nonparametric tests. A total of 179 living donor nephrectomies were performed during the study period-31 open donor nephrectomy (17.3%) and 148 HALDN (82.7%)-without relevant baseline differences, except for creatinine. HALDN has a shorter surgical time (156,473 ± 87.75 minutes vs 165,484 ± 69.95 minutes) and less bleeding (244.59 ± 416.08 mL vs 324.19 ± 197.986 mL) and a shorter duration of hospital stay (3.74 ± 1.336 days vs 4.75 ± 1.226 days). There were no significant differences in surgical complications at 30 days, or graft loss reported; there were 3 conversions (1.7%) from the HALDN to the open technique. There were no differences in renal function in the donors or recipients at the 5th day or the month after surgery. Laparoscopic nephrectomy has replaced open surgery as the gold standard for living kidney donors. HALDN is a safe and feasible procedure when compared with open donor nephrectomy, achieving a shorter surgical time with

  19. Newer trends in the diagnosis of pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jankharia, G R

    1996-12-31

    The contents are indications for the newer modalities i.e. ultrasound, computerized tomography HRTC, magnetic resonance on the pulmonary lesions such as lung diseases, emphysema , tuberculosis, bronchogenic carcinoma.

  20. Newer trends in the diagnosis of pulmonary lesions

    International Nuclear Information System (INIS)

    Jankharia, G.R.

    1995-01-01

    The contents are indications for the newer modalities i.e. ultrasound, computerized tomography HRTC, magnetic resonance on the pulmonary lesions such as lung diseases, emphysema , tuberculosis, bronchogenic carcinoma

  1. Refractory Septic Shock Treated with Nephrectomy under the Support of Extracorporeal Membrane Oxygenation

    Directory of Open Access Journals (Sweden)

    Young Kun Lee

    2015-08-01

    Full Text Available Conventional medical therapies have not been very successful in treating adults with refractory septic shock. The effects of direct hemoperfusion using polymyxin B and veno-arterial extracorporeal membrane oxygenation (ECMO for refractory septic shock remain uncertain. A 66-year-old man was admitted to the emergency department and suffered from sepsis-induced hemodynamic collapse. For hemodynamic improvement, we performed direct hemoperfusion using polymyxin B. Computed tomography scan of this patient revealed emphysematous pyelonephritis (EPN, for which he underwent emergent nephrectomy with veno-arterial ECMO support. To the best of our knowledge, this is the first report of successful treatment of EPN with refractory septic shock using polymyxin B hemoperfusion and nephrectomy under the support of ECMO.

  2. Effects of Open versus Laparoscopic Nephrectomy Techniques on Oxidative Stress Markers in Patients with Renal Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Celestyna Mila-Kierzenkowska

    2013-01-01

    Full Text Available The aim of the study was to determine the concentration of lipid peroxidation products, the activity of selected antioxidant and lysosomal enzymes, and protease inhibitor in patients with renal cell carcinoma who underwent radical nephrectomy. The studied group included 44 patients: 21 of them underwent open surgery, while 23 underwent laparoscopy. Blood samples were collected three times: before treatment and 12 hours and five days after nephrectomy. In blood of participants, the concentration of thiobarbituric acid reactive substances (TBARS, the activity of catalase (CAT, superoxide dismutase (SOD and glutathione peroxidase (GPx, and the activity of acid phosphatase (AcP, arylsulfatase (ASA, cathepsin D (CTSD, and α1-antitrypsin (AAT were assayed. No statistically significant differences in investigated parameters were found between studied groups. Moreover, TBARS concentration and CAT, SOD, and GPx activity were not altered in the course of both types of surgery. Five days after both open and laparoscopic nephrectomy techniques, AAT activity was higher than its activity 12 hours after the procedure. The obtained results suggest that laparoscopy may be used for nephrectomy as effectively as open surgery without creating greater oxidative stress. Reduced period of convalescence at patients treated with laparoscopy may be due to less severe response of acute-phase proteins.

  3. The effect of Mastin® on expression of Nrf2 in the rat heart with subtotally nephrectomy chronic Kidney disease model

    Science.gov (United States)

    Nathania, J.; Soetikno, V.

    2017-08-01

    Chronic kidney disease (CKD) is increasingly prevalent in Indonesia and worldwide. One of the major causes of morbidity and mortality in CKD is the complication of cardiovascular disease. Mastin® is a supplement that is locally produced in Indonesia and is made from extract of mangosteen pericarp, which is reported to have antioxidative, anti-inflammatory, and antitumor properties. The present study aimed to investigate whether Mastin® could improve antioxidant responses in the rat heart during CKD by measuring the expression of nuclear factor erythroid-2-related factor (Nrf)2, a master regulator of antioxidant response elements. RNA was extracted from the heart tissue of three groups of rats: a normal group, a nephrectomy group, and a nephrectomy with Mastin® group. Two-step real-time RT-PCR was then conducted to calculate the relative expression of the Nrf2 gene. Nrf2 expression was markedly decreased in the nephrectomy group vs the normal group, but slightly increas ed in the nephrectomy with Mastin® group vs the nephrectomy group. CKD resulted in impaired activation of the Nrf2 pathway in the rat heart. Although the administration of Mastin® slightly increased Nrf2 expression, it was not enough to confer cardioprotective effects through the Nrf2 pathway.

  4. Cranial pole nephrectomy in the pig model: anatomic analysis of arterial injuries in tridimensional endocasts.

    Science.gov (United States)

    Pereira-Sampaio, Marco A; Henry, Robert W; Favorito, Luciano A; Sampaio, Francisco J B

    2012-06-01

    To assess the intrarenal arteries injuries after cranial pole nephrectomy in a pig model to compare these findings with those in humans. Polyester resin was injected through the ureter and the renal artery to make three-dimensional casts of 61 pig kidneys. The cranial pole of the kidneys was sectioned at four different sites before the solidification of the resin, and the casts were examined for arterial damage. Section performed through the hilus (15 kidneys): The cranial division of the renal artery was sectioned in two (13.33%) cases, the ventral branch of the cranial division of the renal artery was sectioned in 13 (86.7%) cases, and the dorsal branch of the cranial division of the renal artery was sectioned in 11 (73.34%) cases. Section at 0.5 cm cranial to the hilus (16 kidneys): The cranial division of the renal artery was sectioned in 1 (6.25%) case, the ventral branch of the cranial division of the renal artery was sectioned in 14 (87.5%) cases, and the dorsal branch of the cranial division of the renal artery was sectioned in 13 (81.25%) cases. Section at 1.0 cm cranial to the hilus (15 kidneys): The ventral branch of the cranial division of the renal artery was sectioned in five (33.33%) cases, and the dorsal branch of the cranial division of the renal artery was injured in five (33.33%) cases. Section at 1.5 cm cranial to the hilus (15 kidneys): No lesions were found in the main arteries, only in the interlobular branches. As previously demonstrated in humans, sections at 1.0 cm or more cranially to the hilus in pigs also showed a significant decrease in damage to the major intrarenal arteries. Therefore, as regards arterial damage, the pig kidney is a useful model for partial nephrectomy in the cranial (upper) pole.

  5. Newer Trends in Laser Tattoo Removal

    Science.gov (United States)

    Shah, Swapnil D; Aurangabadkar, Sanjeev J

    2015-01-01

    Q switched lasers are the current gold standard for laser tattoo removal. Though these systems are generally quite effective in clearing tattoos & have an established safety record, certain limitations exist while following the standard protocol. To overcome these limitation newer techniques such as multipass method, combination treatments with chemical agent and other laser have been introduced. These methods help in faster, less painful and complication free tattoo removal. PMID:25949019

  6. Newer trends in laser tattoo removal

    Directory of Open Access Journals (Sweden)

    Swapnil D Shah

    2015-01-01

    Full Text Available Q switched lasers are the current gold standard for laser tattoo removal. Though these systems are generally quite effective in clearing tattoos & have an established safety record, certain limitations exist while following the standard protocol. To overcome these limitation newer techniques such as multipass method, combination treatments with chemical agent and other laser have been introduced. These methods help in faster, less painful and complication free tattoo removal.

  7. LAPAROSCOPIC NEPHRECTOMY USING RADIOFREQUENCY THERMAL ABLATION

    Directory of Open Access Journals (Sweden)

    B. Ya. Alekseev

    2012-01-01

    Full Text Available The wide use of current diagnostic techniques, such as ultrasound study, computed tomography, and magnetic resonance imaging, has led to significantly increased detection rates for disease in its early stages. This gave rise to a change in the standards for the treatment of locally advanced renal cell carcinoma (RCC. Laparoscopic nephrectomy (LN has recently become the standard treatment of locally advanced RCC in the clinics having much experience with laparoscopic surgery. The chief drawback of LN is difficulties in maintaining intraoperative hemostasis and a need for creating renal tissue ischemia. The paper gives the intermediate results of application of the new procedure of LN using radiofrequency thermal ablation in patients with non-ischemic early-stage RCC.

  8. Kidney transplantation: A new era of laparoscopic living donor nephrectomy in Indonesia

    Directory of Open Access Journals (Sweden)

    Albertus Marcelino

    2018-01-01

    Conclusion: Laparoscopic living donor nephrectomies had been performed successfully with improvement of surgical parameter in due time. Thus, laparoscopic approach has entered a new era for kidney procurement in Indonesia.

  9. Impact of preoperative calculation of nephron volume loss on future of partial nephrectomy techniques; planning a strategic roadmap for improving functional preservation and securing oncological safety.

    Science.gov (United States)

    Rha, Koon H; Abdel Raheem, Ali; Park, Sung Y; Kim, Kwang H; Kim, Hyung J; Koo, Kyo C; Choi, Young D; Jung, Byung H; Lee, Sang K; Lee, Won K; Krishnan, Jayram; Shin, Tae Y; Cho, Jin-Seon

    2017-11-01

    To assess the correlation of the resected and ischaemic volume (RAIV), which is a preoperatively calculated volume of nephron loss, with the amount of postoperative renal function (PRF) decline after minimally invasive partial nephrectomy (PN) in a multi-institutional dataset. We identified 348 patients from March 2005 to December 2013 at six institutions. Data on all cases of laparoscopic (n = 85) and robot-assisted PN (n = 263) performed were retrospectively gathered. Univariable and multivariable linear regression analyses were used to identify the associations between various time points of PRF and the RAIV, as a continuous variable. The mean (sd) RAIV was 24.2 (29.2) cm 3 . The mean preoperative estimated glomerular filtration rate (eGFR) and the eGFRs at postoperative day 1, 6 and 36 months after PN were 91.0 and 76.8, 80.2 and 87.7 mL/min/1.73 m 2 , respectively. In multivariable linear regression analysis, the amount of decline in PRF at follow-up was significantly correlated with the RAIV (β 0.261, 0.165, 0.260 at postoperative day 1, 6 and 36 months after PN, respectively). This study has the limitation of its retrospective nature. Preoperatively calculated RAIV significantly correlates with the amount of decline in PRF during long-term follow-up. The RAIV could lead our research to the level of prediction of the amount of PRF decline after PN and thus would be appropriate for assessing the technical advantages of emerging techniques. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  10. Hand-assisted bilateral nephrectomy in a patient with adult polycystic kidney disease

    Directory of Open Access Journals (Sweden)

    Marcello Alves Pinto

    Full Text Available CONTEXT: Dominantly autosomal polycystic disease is characterized by multiple bilateral and non-functional cysts, which lead to progressive kidney failure. OBJECTIVE: Our objective was to report on a case of hand-assisted bilateral nephrectomy in a 28-year-old female patient with adult polycystic disease and recurring pyelonephritis in a kidney transplant program. CASE REPORT: A hand-assisted bilateral nephrectomy was performed through a supra-umbilical median incision of approximately 6 cm, and with 3 ports of 10 mm. The length of the surgery was 3 hours and 15 minutes. The kidneys were removed after the aspiration of some cysts through the supra-umbilical incision. Pain control was achieved via the use of analgesics. The blood loss during surgery was 160 ml. During the postoperative period, the patient developed right-side pneumothorax, which was drained with no further occurrence. This drain was kept in place for 48 hours. The length of hospitalization was 4 days.

  11. Initial experience with hand-assisted laparoscopic donor nephrectomy

    DEFF Research Database (Denmark)

    Wiborg, Majken Højrup; Toft, Anja; Jahn, Henrik

    2017-01-01

    -38 kg/m²) in males. The median intraoperative bleeding was 175 ml. The median warm ischaemia time was 3.2 min (1.5-6.7 min). The median operative time was 230 min (161-360 min). The median hospital stay was 4 days (2-10 days). Thirty donors (28%) had 34 early complications. Six donors (6%) needed...... recipients had a functional transplant after 1 year. CONCLUSION: Hand-assisted donor nephrectomy is a safe procedure. Potential candidates should be advised...

  12. Relationship between changes of serum leptin levels and degree of glomerulosclerosis in rats after 5/6 nephrectomy

    International Nuclear Information System (INIS)

    Yang Licai; Zhang Daoyou; Zhu Xinjian; Wang Yuwei; Gao Chaoqing; Xu Haihong

    2006-01-01

    Objective: To investigate the relationship between changes of serum leptin levels and glomerulosclerosis index, TGF-β 1 expression at glomerulus as well as degree of ECM proliferation in rats after 5/6 nephrectomy. Methods: Eight rats underwent two-stage 5/6 nephrectomy to establish a progressive glomeruloselerosis model. Six weeks after the second operation, the rats were sacrificed, the renal tissue was examined with routine pathological sections for study of glomerulosclerosis as well as with immunohistochemical studies for TGF-β 1 , collagen IV and fibronectin expressions. Six rats underwent sham operation served as controls. Serum creatinine, urea nitrogen and leptin levels were measured in all these animals. Results: The serum levels of leptin were significantly higher in rats after 5/6 nephrectomy than the rats with sham operations (14.88 ± 1.46ng/ml vs 10.84 ± 2.67ng/ml, P < 0. 01 ). Serum levels of leptin were positively correlated with the glomeruloselerosis index and collagen IV, fibronectin expressions ( P < 0.01 ). Conclusion: Hyperleptinemia may be one of the causative factors of development of glomerulosclerosis. (authors)

  13. Segmental thoracic spinal anesthesia in patient with Byssinosis undergoing nephrectomy

    OpenAIRE

    Patel, Kiran; Salgaonkar, Sweta

    2012-01-01

    Byssinosis is an occupational disease occurring commonly in cotton mill workers; it usually presents with features of chronic obstructive pulmonary disease (COPD). The management of patients with COPD presents a significant challenges to the anesthetist. Regional anesthesia is preferred in most of these patients to avoid perioperative and postoperative complications related to general anesthesia. We report a known case of Byssinosis who underwent nephrectomy under segmental spinal anesthesia ...

  14. Newer methods of extraction of teeth

    Directory of Open Access Journals (Sweden)

    MHendra Chandha

    2016-06-01

    Full Text Available Atraumatic extraction methods are deemed to be important to minimize alveolar bone loss after tooth extraction. With the advent of such techniques, exodontia is no more a dreaded procedure in anxious patients. Newer system and techniques for extraction of teeth have evolved in the recent few decades. This article reviews and discusses new techniques to make simple and complex exodontias more efficient with improved patient outcomes. This includes physics forceps, powered periotome, piezosurgery, benex extractor, sonic instrument for bone surgery, lasers.

  15. Investigating the effects of inhaling ginger essence on post-nephrectomy nausea and vomiting.

    Science.gov (United States)

    Adib-Hajbaghery, Mohsen; Hosseini, Fatemeh Sadat

    2015-12-01

    There is a knowledge gap regarding the effects of ginger essence on postoperative nausea and vomiting. This study aimed to evaluate the effect of ginger essence on post-nephrectomy nausea and vomiting. A randomized controlled trial was conducted. This study was conducted from third April to first October 2014 in Labbafinejad hospital, Tehran, Iran. Totally, 120 nephrectomy patients were randomly allocated to either the treatment or the control groups. After nephrectomy, we applied two drops of ginger essence to a 2 × 2-inch gauze that was attached to the patients' collars in the treatment group to allow patients to inhale the evaporated essence along with the air room and then repeated every 30 min for two hours. The control group was similarly treated with normal saline. Nausea was assessed using a visual analogue scale every 30 min for two hours and at the sixth hour after surgery. The paired- and independent-samples t and repeated measures analysis of variance tests were used for data analysis. The means nausea intensity were in the treatment and the control groups were 7.09 ± 1.59 and 7.40 ± 1.71 at thirty minutes after surgery (P value > 0.05). However, the mean nausea intensity in the treatment group at the four subsequent times were significantly lower than the control group (P value ginger essence has positive effect on postoperative nausea and vomiting. Using ginger essence for managing postoperative nausea and vomiting is recommended. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. C-reactive protein in patients with advanced metastatic renal cell carcinoma: Usefulness in identifying patients most likely to benefit from initial nephrectomy

    International Nuclear Information System (INIS)

    Ito, Hiroki; Kishida, Takeshi; Miura, Takeshi; Kubota, Yoshinobu; Yao, Masahiro; Shioi, Koichi; Murakami, Takayuki; Takizawa, Akitoshi; Sano, Futoshi; Kawahara, Takashi; Mizuno, Nobuhiko; Makiyama, Kazuhide; Nakaigawa, Noboru

    2012-01-01

    C-reactive protein (CRP) is considered a useful serum marker for patients with RCC. However, its clinical utility in advanced metastatic renal cell carcinoma (AM-RCC), particularly in deciding whether to perform nephrectomy at the onset, is not well studied. We retrospectively evaluated 181 patients with AM-RCC, including 18 patients underwent potentially curative surgery, 111 underwent cytoreductive nephrectomy, and 52 received medical treatment only. CRP cutoff points were determined by receiver operating characteristic (ROC) curve analysis. Kaplan-Meier and Cox regression analyses were used for survival tests. ROC analysis suggested that grouping patients according to 3 CRP ranges was a rational model. Patients with highly elevated CRP (≥67.0 mg/L) presented remarkably poor prognosis despite treatment (nephrectomy or medical treatment only). Cox regression models demonstrated that risk factors of overall survival for patients who underwent nephrectomy were the CRP ranges defined in this study (≤18.0 mg/L, >18.0 and <67.0 mg/L, and ≥67.0 mg/L), ECOG PS (0, 1, and ≥2), and number of metastatic organ sites (0–1 and ≥2). The retrospective design is a limitation of this study. Our study demonstrated that the serum CRP level is a statistically significant prognostic parameter for patients with AM-RCC. The data also indicated that pretreatment serum CRP level provides useful prognostic information that helps in deciding whether to perform initial nephrectomy for patients with AM-RCC

  17. Segmental thoracic spinal anesthesia in patient with Byssinosis undergoing nephrectomy.

    Science.gov (United States)

    Patel, Kiran; Salgaonkar, Sweta

    2012-01-01

    Byssinosis is an occupational disease occurring commonly in cotton mill workers; it usually presents with features of chronic obstructive pulmonary disease (COPD). The management of patients with COPD presents a significant challenges to the anesthetist. Regional anesthesia is preferred in most of these patients to avoid perioperative and postoperative complications related to general anesthesia. We report a known case of Byssinosis who underwent nephrectomy under segmental spinal anesthesia at the low thoracic level.

  18. Newer Root Canal Irrigants in Horizon: A Review

    Directory of Open Access Journals (Sweden)

    Sushma Jaju

    2011-01-01

    Full Text Available Sodium hypochloride is the most commonly used endodontic irrigant, despite limitations. None of the presently available root canal irrigants satisfy the requirements of ideal root canal irrigant. Newer root canal irrigants are studied for potential replacement of sodium hypochloride. This article reviews the potential irrigants with their advantages and limitations with their future in endodontic irrigation.

  19. Pressure ulcers: Current understanding and newer modalities of treatment

    Directory of Open Access Journals (Sweden)

    Surajit Bhattacharya

    2015-01-01

    Full Text Available This article reviews the mechanism, symptoms, causes, severity, diagnosis, prevention and present recommendations for surgical as well as non-surgical management of pressure ulcers. Particular focus has been placed on the current understandings and the newer modalities for the treatment of pressure ulcers. The paper also covers the role of nutrition and pressure-release devices such as cushions and mattresses as a part of the treatment algorithm for preventing and quick healing process of these wounds. Pressure ulcers develop primarily from pressure and shear; are progressive in nature and most frequently found in bedridden, chair bound or immobile people. They often develop in people who have been hospitalised for a long time generally for a different problem and increase the overall time as well as cost of hospitalisation that have detrimental effects on patient′s quality of life. Loss of sensation compounds the problem manifold, and failure of reactive hyperaemia cycle of the pressure prone area remains the most important aetiopathology. Pressure ulcers are largely preventable in nature, and their management depends on their severity. The available literature about severity of pressure ulcers, their classification and medical care protocols have been described in this paper. The present treatment options include various approaches of cleaning the wound, debridement, optimised dressings, role of antibiotics and reconstructive surgery. The newer treatment options such as negative pressure wound therapy, hyperbaric oxygen therapy, cell therapy have been discussed, and the advantages and disadvantages of current and newer methods have also been described.

  20. Pressure ulcers: Current understanding and newer modalities of treatment

    Science.gov (United States)

    Bhattacharya, Surajit; Mishra, R. K.

    2015-01-01

    This article reviews the mechanism, symptoms, causes, severity, diagnosis, prevention and present recommendations for surgical as well as non-surgical management of pressure ulcers. Particular focus has been placed on the current understandings and the newer modalities for the treatment of pressure ulcers. The paper also covers the role of nutrition and pressure-release devices such as cushions and mattresses as a part of the treatment algorithm for preventing and quick healing process of these wounds. Pressure ulcers develop primarily from pressure and shear; are progressive in nature and most frequently found in bedridden, chair bound or immobile people. They often develop in people who have been hospitalised for a long time generally for a different problem and increase the overall time as well as cost of hospitalisation that have detrimental effects on patient's quality of life. Loss of sensation compounds the problem manifold, and failure of reactive hyperaemia cycle of the pressure prone area remains the most important aetiopathology. Pressure ulcers are largely preventable in nature, and their management depends on their severity. The available literature about severity of pressure ulcers, their classification and medical care protocols have been described in this paper. The present treatment options include various approaches of cleaning the wound, debridement, optimised dressings, role of antibiotics and reconstructive surgery. The newer treatment options such as negative pressure wound therapy, hyperbaric oxygen therapy, cell therapy have been discussed, and the advantages and disadvantages of current and newer methods have also been described. PMID:25991879

  1. Medline Plus

    Full Text Available ... Mission Medical Center, Merriam, KS, 05/04/2012) Kidney Cancer Robot Assisted Partial Nephrectomy Using Fluorescence (Shawnee Mission ... NC, 09/17/2015) Kidneys and Urinary System Kidney Cancer Robot Assisted Partial Nephrectomy Using Fluorescence (Shawnee Mission ...

  2. Cytoreductive nephrectomy vs medical therapy as initial treatment: a rational approach to the sequence question in metastatic renal cell carcinoma.

    Science.gov (United States)

    Spiess, Philippe E; Fishman, Mayer N

    2010-10-01

    Renal cell carcinoma (RCC) can be considered as two distinct entities: localized and metastatic disease. We conducted a review of the scientific literature published within the past decade pertaining to cytoreductive nephrectomy for metastatic RCC. Retrospective data and historical prospective series have demonstrated the survival benefit of debulking nephrectomy in well-selected RCC patients. New medical therapies, including vascular endothelial growth factor and mTOR pathway blocking drugs, are active biological agents, with survival improvement and potential regression of metastatic and primary tumors. Our current therapeutic challenge is the optimal integration of multimodal therapy consisting of systemic therapy and surgery including cytoreductive nephrectomy, debulking, and metastasectomy. Empiric data to guide this decision are limited. The decision concerning whether medical or surgical therapy should be the primary treatment approach selected must be made on an individual basis, taking into account patient performance status, clinical parameters, and physician expertise and recommendations, thus making each case a unique therapeutic challenge.

  3. Radical nephrectomy performed by open, laparoscopy with or without hand-assistance or robotic methods by the same surgeon produces comparable perioperative results

    Directory of Open Access Journals (Sweden)

    Tanya Nazemi

    2006-02-01

    Full Text Available PURPOSE: Radical nephrectomy can be performed using open or laparoscopic (with or without hand assistance methods, and most recently using the da Vinci Surgical Robotic System. We evaluated the perioperative outcomes using a contemporary cohort of patients undergoing radical nephrectomy by one of the above 4 methods performed by the same surgeon. MATERIALS AND METHODS: The relevant clinical information on 57 consecutive patients undergoing radical nephrectomy from September 2000 until July 2004 by a single surgeon was entered in a Microsoft Access DatabaseTM and queried. Following appropriate statistical analysis, p values < 0.05 were considered significant. RESULTS: Of 57 patients, the open, robotic, laparoscopy with or without hand assistance radical nephrectomy were performed in 18, 6, 21, and 12 patients, respectively. The age, sex, body mass index (BMI, incidence of malignancy, specimen and tumor size, tumor stage, Fuhrman grade, hospital stay, change in postoperative creatinine, drop in hemoglobin, and perioperative complications were not significantly different between the methods. While the estimated median blood loss, postoperative narcotic use for pain control, and hospital stay were significantly higher in the open surgery method (p < 0.05, the median operative time was significantly shorter compared to the robotic method (p = 0.02. Operating room costs were significantly higher in the robotic and laparoscopic groups; however, there was no significant difference in total hospital costs between the 4 groups. CONCLUSIONS: The study demonstrates that radical nephrectomy can be safely performed either by open, robotic, or laparoscopic with or without hand assistance methods without significant difference in perioperative complication rates. A larger cohort and longer follow up are needed to validate our findings and establish oncological outcomes.

  4. Novel prediction model of renal function after nephrectomy from automated renal volumetry with preoperative multidetector computed tomography (MDCT).

    Science.gov (United States)

    Isotani, Shuji; Shimoyama, Hirofumi; Yokota, Isao; Noma, Yasuhiro; Kitamura, Kousuke; China, Toshiyuki; Saito, Keisuke; Hisasue, Shin-ichi; Ide, Hisamitsu; Muto, Satoru; Yamaguchi, Raizo; Ukimura, Osamu; Gill, Inderbir S; Horie, Shigeo

    2015-10-01

    The predictive model of postoperative renal function may impact on planning nephrectomy. To develop the novel predictive model using combination of clinical indices with computer volumetry to measure the preserved renal cortex volume (RCV) using multidetector computed tomography (MDCT), and to prospectively validate performance of the model. Total 60 patients undergoing radical nephrectomy from 2011 to 2013 participated, including a development cohort of 39 patients and an external validation cohort of 21 patients. RCV was calculated by voxel count using software (Vincent, FUJIFILM). Renal function before and after radical nephrectomy was assessed via the estimated glomerular filtration rate (eGFR). Factors affecting postoperative eGFR were examined by regression analysis to develop the novel model for predicting postoperative eGFR with a backward elimination method. The predictive model was externally validated and the performance of the model was compared with that of the previously reported models. The postoperative eGFR value was associated with age, preoperative eGFR, preserved renal parenchymal volume (RPV), preserved RCV, % of RPV alteration, and % of RCV alteration (p volumetry and clinical indices might yield an important tool for predicting postoperative renal function.

  5. Intravesical ligation as a new technique to manage a refluxing native ureter without simultaneous nephrectomy in renal transplantation.

    Science.gov (United States)

    Guzmán, J A

    2012-12-01

    This article aims to describe an original technique to correct refluxing native ureters observed during a prerenal transplantation study. The correction is performed by intravesical ligation of the native refluxing ureters at the same time as renal transplantation without simultaneous nephrectomy. Between January 2004 and December 2010 we performed intravesical ligation of a refluxing ureter simultaneous with a transplantation procedure without a concomittant native nephrectomy in 12 of 345 subjects (3.47%). The 8 bilateral and 4 unilateral ligations were performed on 11 cadaveric and 1 living-related nonidentical donor transplantations. The implantation of the kidney donor ureter was performed anatomically in the bladder trigone through a transvesical ureteroneocystostomy with a transmural, submucosal antireflux tunnel. Early and late postoperative recovery was satisfactory in all patients. There was no documented kidney area pain, proven urinary tract infection, morbidity or mortality attributed to the procedure. Intravesical ligation is a practical technique to manage vesicoureteral reflux into the native ureters simultaneously with the ureteral implantation of the kidney donor in a single surgical renal transplant procedure without native kidney nephrectomy. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Transumbilical laparoendoscopic single-site donor nephrectomy: Without the use of a single port access device

    Directory of Open Access Journals (Sweden)

    Deepak Dubey

    2011-01-01

    Conclusions : Transumbilical LESS-DN can be cost-effectively performed using conventional laparoscopy instruments and without the need for a single port access device. Warm ischemia times with this technique are comparable with that during conventional multiport laparoscopic donor nephrectomy.

  7. Laparoscopic versus open nephrectomy for live kidney donors.

    Science.gov (United States)

    Wilson, Colin H; Sanni, Aliu; Rix, David A; Soomro, Naeem A

    2011-11-09

    Waiting lists for kidney transplantation continue to grow and live organ donation has become more important as the number of brain stem dead cadaveric organ donors continues to fall. The major disincentive to potential kidney donors is the pain and morbidity associated with open surgery. To identify the benefits and harms of using laparoscopic compared to open nephrectomy techniques to recover kidneys from live organ donors. We searched the online databases CENTRAL (in The Cochrane Library 2010, Issue 2), MEDLINE (January 1966 to January 2010) and EMBASE (January 1980 to January 2010) and handsearched textbooks and reference lists. Randomised controlled trials comparing laparoscopic donor nephrectomy (LDN) with open donor nephrectomy (ODN). Two review authors independently screened titles and abstracts for eligibility, assessed study quality, and extracted data. We contacted study authors for additional information where necessary. Six studies were identified that randomised 596 live kidney donors to either LDN or ODN arms. All studies were assessed as having low or unclear risk of bias for selection bias, allocation bias, incomplete outcome data and selective reporting bias. Four of six studies had high risk of bias for blinding. Various different combinations of techniques were used in each study, resulting in heterogeneity in the results. The conversion rate from LDN to ODN ranged from 1% to 1.8%. LDN was generally found to be associated with reduced analgesia use, shorter hospital stay, and faster return to normal physical functioning. The extracted kidney was exposed to longer warm ischaemia periods (2 to 17 minutes) with no associated short-term consequences. ODN was associated with shorter duration of procedure. For those outcomes that could be meta-analysed there were no significant differences between LDN or ODN for perioperative complications (RR 0.87, 95% CI 0.47 to 4.59), reoperations (RR 0.57, 95% CI 0.09 to 3.64), early graft loss (RR 0.31, 95% CI 0

  8. Reducing radiation exposure in an electrophysiology lab with introduction of newer fluoroscopic technology

    Directory of Open Access Journals (Sweden)

    Munish Sharma

    2017-09-01

    Full Text Available The use of fluoroscopic devices exposes patients and operators to harmful effects of ionizing radiation in an electrophysiology (EP lab. We sought to know if the newer fluoroscopic technology (Allura Clarity installed in a hybrid EP helps to reduce prescribed radiation dose. We performed radiation dose analysis of 90 patients who underwent various procedures in the EP lab at a community teaching hospital after the introduction of newer fluoroscopic technology in June of 2016.Watchman device insertion, radiofrequency ablation procedures, permanent pacemaker (PPM/implantable cardioverter defibrillator (ICD placement and battery changes were included in the study to compare radiation exposure during different procedures performed commonly in an EP lab. In all cases of watchman device placement, radiofrequency ablation procedures, PPM/ICD placement and battery changes, there was a statistically significant difference (<0.05 in radiation dose exposure. Significant reduction in radiation exposure during various procedures performed in an EP lab was achieved with aid of newer fluoroscopic technology and better image detection technology.

  9. Impact of Cytoreductive Nephrectomy on Survival in Patients with Metastatic Renal Cell Carcinoma Treated by Targeted Therapy

    Directory of Open Access Journals (Sweden)

    Yan Song

    2016-01-01

    Conclusions: Five risk factors (age, BMI, LDH, serum calcium, and number of metastatic sites seemed to be helpful for selecting patients who would benefit from undergoing upfront cytoreductive nephrectomy.

  10. Medline Plus

    Full Text Available ... Center, Merriam, KS, 05/04/2012) Kidney Cancer Robot Assisted Partial Nephrectomy Using Fluorescence (Shawnee Mission Medical Center, Merriam, KS, 10/ ... 17/2015) Kidneys and Urinary System ... Cancer Robot Assisted Partial Nephrectomy Using Fluorescence (Shawnee Mission Medical Center, Merriam, KS, 10/ ...

  11. Renal cell carcinoma-associated adult dermatomyositis treated laparoscopic nephrectomy

    Directory of Open Access Journals (Sweden)

    Elizabeth Nevins

    2013-01-01

    Full Text Available A 77-year-old female, who suffered from rheumatoid arthritis and hypothyroidism, developed severe muscle weakness. Clinical features, blood results and muscle biopsy suggested a possible diagnosis of dermatomyositis. A computed tomography of the chest, abdomen and pelvis showed a solid mass in the left kidney. She underwent a left laparoscopic nephrectomy and histology confirmed conventional (clear cell renal cell carcinoma. She recovered slowly and almost back to normal life after 6 months. Early appreciation of the typical skin rash may provide a clue to the diagnosis and screening for neoplasm may improve prognosis.

  12. Unilateral Dependant Pulmonary Edema During Laparoscopic Donor Nephrectomy: Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Manisha Modi

    2009-01-01

    Full Text Available Unilateral pulmonary edema of the dependant lung was observed in three patients during laparoscopic donor nephrectomy. Patients were treated with 02 supplementation by face mask, fluid restriction and diuretic. All the patients were relieved of symptoms with radiological improvement. The possible causes of this unusual complication following laparoscopic surgery appear to be prolonged lateral decubitus position and high intraoperative fluid infusion.

  13. Unusual complication after laparoscopic left nephrectomy for renal tumour: a case report

    Directory of Open Access Journals (Sweden)

    Arantxa Arruabarrena

    2010-06-01

    Full Text Available In splenic rupture after blunt trauma, iatrogenic spleen injury or non-traumatic cases it is essential that the surgeonmakes correct decisions. Conservative treatment must include continual monitoring and repeated, stringent evaluationof the splenic injury (the American Association for the Surgery of Trauma – AAST in order to avoid any delay indiagnosis of delayed spleen rupture and the high mortality it causes. We present the case of an unexpected complicationafter radical nephrectomy performed for renal cell carcinoma. A 61-year old man sought medical help for acuteabdominal pain. He presented with some cardiovascular risk factors (diabetes mellitus, smoker of 30 cigarettes perday and moderate alcohol use. In the Emergency Unit, computed tomography scan revealed an incidental tumour ofthe left kidney. Nephrectomy via the laparoscopic approach was done without any iatrogenic complications, with lessthan 500 cc of blood loss. Firm adhesions between the spleen and abdominal wall, which caused some minor tractionthat resulted in a small subcapsular haematoma, were the only surprising intraoperative finding. Within the first 6 h,the patient presented with haemodynamic instability, while the drain evacuated less than 50 cc of discharge.However, CT scan showed that subcapsular haematoma had increased to the size of 10 × 10 cm without freeperitoneal fluid present. Unfortunately, 6 h later emergency surgery had to be performed due to rupture of thesubcapsular splenic haematoma. Massive haemoperitoneum was evacuated and the splenic capsule was the onlyremnant of the spleen that could be found on re-intervention. So far, it is the first case describing an increasing subcapsularhaematoma of the spleen, most likely caused by the traction of firm adhesions to the organ. We discussmeans to avoid such a complication: with liberation of the adhesions, placement of a perisplenic mesh, embolizationof the splenic artery or subcapsular nephrectomy. An acute

  14. Unilateral Partial Nephrectomy with Warm Ischemia Results in Acute Hypoxia Inducible Factor 1-Alpha (HIF-1α and Toll-Like Receptor 4 (TLR4 Overexpression in a Porcine Model.

    Directory of Open Access Journals (Sweden)

    Zhiyong Zhang

    Full Text Available Ischemia/reperfusion (I/R during partial nephrectomy (PN contributes to acute kidney injury (AKI, which is inaccurately assessed using existent clinical markers of renal function. We evaluated I/R-related changes in expression in hypoxia inducible factor 1α (HIF-1α and toll-like receptor 4 (TLR4, within kidney tissue and peripheral blood leukocytes (PBL in a porcine model of PN.Three adult pigs each underwent unilateral renal hilar cross clamping for 180 min followed by a 15 min reperfusion. The contralateral kidney served as control. Biopsies of clamped kidneys were obtained at baseline (time 0, every 60 min during the hypoxic phase, and post-reperfusion. Control kidneys were biopsied once at 180 min. Peripheral blood was sampled at time 0, every 30 min during the hypoxic phase, and post-reperfusion. HIF-1α and TLR4 expression in kidney tissue and PBL were analyzed by Western blotting. I/R-related histological changes were assessed.Expression of HIF-1α in clamped kidneys and PBL was below detection level at baseline, rising to detectable levels after 60 min of hypoxia, and continuing to rise throughout the hypoxic and reperfusion phases. Expression of TLR-4 in clamped kidneys followed a similar trend with initial detection after 30-60 min of hypoxia. Control kidneys exhibited no change in HIF-1α or TLR-4 expression. I/R-related histologic changes were minimal, primarily mild tubular dilatation.In a porcine model of PN, HIF-1α and TLR4 exhibited robust, I/R-related increases in expression in kidney tissue and PBL. Further studies investigating these molecules as potential markers of AKI are warranted.

  15. Newer agents in antiplatelet therapy: a review

    Directory of Open Access Journals (Sweden)

    Yeung J

    2012-06-01

    Full Text Available Jennifer Yeung, Michael HolinstatCardeza Foundation for Hematologic Research, Department of Medicine, Thomas Jefferson University, Philadelphia, PA, USAAbstract: Antiplatelet therapy remains the mainstay in preventing aberrant platelet activation in pathophysiological conditions such as myocardial infarction, ischemia, and stroke. Although there has been significant advancement in antiplatelet therapeutic approaches, aspirin still remains the gold standard treatment in the clinical setting. Limitations in safety, efficacy, and tolerability have precluded many of the antiplatelet inhibitors from use in patients. Unforeseen incidences of increased bleeding risk and recurrent arterial thrombosis observed in patients have hampered the development of superior next generation antiplatelet therapies. The pharmacokinetic and pharmacodynamic profiles have also limited the effectiveness of a number of antiplatelet inhibitors currently in use due to variability in metabolism, time to onset, and reversibility. A focused effort in the development of newer antiplatelet therapies to address some of these shortcomings has resulted in a significant number of potential antiplatelet drugs which target enzymes (phosphodiesterase, cyclooxygenase, receptors (purinergic, prostaglandins, protease-activated receptors, thromboxane, and glycoproteins (αIIbß3, GPVI, vWF, GPIb in the platelet. The validation and search for newer antiplatelet therapeutic approaches proven to be superior to aspirin is still ongoing and should yield a better pharmacodynamic profile with fewer untoward side-effects to what is currently in use today.Keywords: platelet aggregation inhibitors, blood platelets, purinergic P2Y receptor antagonists, receptor, PAR-1, platelet glycoprotein GPIIb-IIIa, thrombosis

  16. Clinical toxicology of newer recreational drugs.

    Science.gov (United States)

    Hill, Simon L; Thomas, Simon H L

    2011-10-01

    Novel synthetic 'designer' drugs with stimulant, ecstasy-like (entactogenic) and/or hallucinogenic properties have become increasingly popular among recreational drug users in recent years. The substances used change frequently in response to market trends and legislative controls and it is an important challenge for poisons centres and clinical toxicologists to remain updated on the pharmacological and toxicological effects of these emerging agents. To review the available information on newer synthetic stimulant, entactogenic and hallucinogenic drugs, provide a framework for classification of these drugs based on chemical structure and describe their pharmacology and clinical toxicology. A comprehensive review of the published literature was performed using PUBMED and Medline databases, together with additional non-peer reviewed information sources, including books, media reports, government publications and internet resources, including drug user web forums. Novel synthetic stimulant, entactogenic or hallucinogenic designer drugs are increasingly available to users as demonstrated by user surveys, poisons centre calls, activity on internet drug forums, hospital attendance data and mortality data. Some population sub groups such as younger adults who attend dance music clubs are more likely to use these substances. The internet plays an important role in determining the awareness of and availability of these newer drugs of abuse. Most novel synthetic stimulant, entactogenic or hallucinogenic drugs of abuse can be classified according to chemical structure as piperazines (e.g. benzylpiperazine (BZP), trifluoromethylphenylpiperazine), phenethylamines (e.g. 2C or D-series of ring-substituted amfetamines, benzodifurans, cathinones, aminoindans), tryptamines (e.g. dimethyltryptamine, alpha-methyltryptamine, ethyltryptamine, 5-methoxy-alphamethyltryptamine) or piperidines and related substances (e.g. desoxypipradrol, diphenylprolinol). Alternatively classification may

  17. Radiopharmaceuticals for oncology: status and newer trends- an overview

    International Nuclear Information System (INIS)

    Ramamoorthy, N.; Prabhakar, G.

    1997-01-01

    Radiopharmaceuticals have provided a powerful means in the diagnosis and follow up of cancer patients. Radiopharmaceuticals for the treatment of metastatic thyroid cancer and palliation of metastatic bone pain are in extensive use. Newer agents are on the anvil for more efficacious diagnosis and therapy. This article gives an overview of the status and trends in this context. (author)

  18. Lack of effect of bilateral nephrectomy on the pharmacokinetics of 14C-indapamide (REV 2555) and its metabolites in the dog

    International Nuclear Information System (INIS)

    Klunk, L.J.; Mangat, S.; Treitman, J.A.; Grebow, P.E.

    1983-01-01

    Renal impairment can affect the disposition of metabolites, as well as unchanged drug, especially when there is significant renal clearance of metabolites. The pharmacokinetics of indapamide, a highly metabolized drug, and total indapamide equivalents (as an indicator of metabolites plus unchanged drug) were determined in the anephric dog. An intravenous dose of 14 C-indapamide was administered to dogs first after a sham-operation, and then following bilateral nephrectomy. The disposition of total indapamide equivalents, calculated from total radioactivity, was not substantially different after nephrectomy as compared to after sham-operation, with an increase after nephrectomy in the area under the blood level curve (+26.2%), and decreases in the elimination rate constant (-6.9%), volume of distribution (-12.7%) and total blood clearance (-21.9%). The only statistically significant change was the decrease in the volume of distribution. The elimination kinetics of unchanged drug were also qualitatively similar in both cases. After nephrectomy, a decrease was seen in the elimination rate constant (-10.9%) and the volume of distribution (-16.3%) while slight increases in the total blood clearance (+1.9%) and the area under the blood level curve (+4.8%) were noted. These findings could have important implications for advantageous use of indapamide in treatment of hypertensive patients with renal failure since these data suggest that metabolites as well as unchanged drug could still be effectively eliminated by an alternate, non-renal route, thus minimizing accumulation of these compounds

  19. Anaesthesia for laparoscopic nephrectomy: Does end-tidal carbon dioxide measurement correlate with arterial carbon dioxide measurement?

    Science.gov (United States)

    Jayan, Nithin; Jacob, Jaya Susan; Mathew, Mohan

    2018-04-01

    Not many studies have explored the correlation between arterial carbon dioxide tension (PaCO 2 ) and end-tidal carbon dioxide tension (ETCO 2 ) in surgeries requiring pneumoperitoneum of more than 1 hour duration with the patient in non-supine position. The aim of our study was to evaluate the correlation of ETCO 2 with PaCO 2 in patients undergoing laparoscopic nephrectomy under general anaesthesia. A descriptive study was performed in thirty patients undergoing laparoscopic nephrectomy from September 2014 to August 2015. The haemodynamic parameters, minute ventilation, PaCO 2 and ETCO 2 measured at three predetermined points during the procedure were analysed. Correlation was checked using Pearson's Correlation Coefficient Test. P <0.05 was considered statistically significant. Statistical analysis of the values showed a positive correlation between ETCO 2 and PaCO 2 ( P < 0.05). Following carbon dioxide insufflation, both ETCO 2 and PaCO 2 increased by 5.4 and 6.63 mmHg, respectively, at the end of the 1 st hour. The PaCO 2 -ETCO 2 gradient was found to increase during the 1 st hour following insufflation (4.07 ± 2.05 mmHg); it returned to the pre-insufflation values in another hour (2.93 ± 1.43 mmHg). Continuous ETCO 2 monitoring is a reliable indicator of the trend in arterial CO 2 fluctuations in the American Society of Anesthesiologists Grades 1 and 2 patients undergoing laparoscopic nephrectomy under general anaesthesia.

  20. Ultrasound-guided transversus abdominis plane blocks for patients undergoing laparoscopic hand-assisted nephrectomy: a randomized, placebo-controlled trial

    Directory of Open Access Journals (Sweden)

    Aniskevich S

    2014-04-01

    Full Text Available Stephen Aniskevich,1 C Burcin Taner,2 Dana K Perry,2 Christopher B Robards,3 Steven B Porter,3 Colleen S Thomas,4 Ilana I Logvinov,5 Steven R Clendenen41Department of Anesthesia, Division of Transplant Anesthesia, 2Department of Transplantation, 3Department of Anesthesia, Division of Regional Anesthesia, 4Division of Health Sciences Research, Section of Biostatistics, 5Department of Anesthesia, Mayo Clinic Florida, Jacksonville, FL, USAAbstract: Postoperative pain is a common complaint following living kidney donation or tumor resection using the laparoscopic hand-assisted technique. To evaluate the potential analgesic benefit of transversus abdominis plane blocks, we conducted a randomized, double-blind, placebo-controlled study in 21 patients scheduled to undergo elective living-donor nephrectomy or single-sided nephrectomy for tumor. Patients were randomized to receive either 20 mL of 0.5% ropivacaine or 20 mL of 0.9% saline bilaterally to the transversus abdominis plane under ultrasound guidance. We found that transversus abdominis plane blocks reduced overall pain scores at 24 hours, with a trend toward decreased total morphine consumption. Nausea, vomiting, sedation, and time to discharge were not significantly different between the two study groups.Keywords: transversus abdominis plane block, nephrectomy, kidney donor, ultrasound guidance

  1. Laparoscopic donor nephrectomy increases the supply of living donor kidneys: a center-specific microeconomic analysis.

    Science.gov (United States)

    Kuo, P C; Johnson, L B

    2000-05-27

    A tenet of microeconomics is that new technology will shift the supply curve to the right. Laparoscopic donor nephrectomy (LDN) is a new technique for removal of living donor kidneys. Centers performing this procedure have noted an increased number of patients presenting for donor evaluation. This has not been previously studied. The records of all LDN performed from May 1998 to February 1999 were reviewed. The following variables were examined: sex, age, related vs. unrelated donation, estimated blood loss, i.v. analgesia, length of stay, and time out of work. Donors undergoing traditional open donor nephrectomy during January 1997 to May 1998 served as the control group. A composite cost index was constructed. LDN significantly decreased length of stay, pain, and time out of work; the supply function shifted to the right. Telephone interviews revealed that 47% donated solely because of the LDN procedure. LDN increases the supply of living donor kidneys.

  2. Renal structure and function evaluation of rats from dams that received increased sodium intake during pregnancy and lactation submitted or not to 5/6 nephrectomy.

    Science.gov (United States)

    Marin, Evelyn Cristina Santana; Balbi, Ana Paula Coelho; Francescato, Heloísa Della Coletta; Alves da Silva, Cleonice Giovanini; Costa, Roberto Silva; Coimbra, Terezila M

    2008-01-01

    Adult rats submitted to perinatal salt overload presented renin-angiotensin system (RAS) functional disturbances. The RAS contributes to the renal development and renal damage in a 5/6 nephrectomy model. The aim of the present study was to analyze the renal structure and function of offspring from dams that received a high-salt intake during pregnancy and lactation. We also evaluated the influence of the prenatal high-salt intake on the evolution of 5/6 nephrectomy in adult rats. A total of 111 sixty-day-old rat pups from dams that received saline or water during pregnancy and lactation were submitted to 5/6 nephrectomy (nephrectomized) or to a sham operation (sham). The animals were killed 120 days after surgery, and the kidneys were removed for immunohistochemical and histological analysis. Systolic blood pressure (SBP), albuminuria, and glomerular filtration rate (GFR) were evaluated. Increased SBP, albuminuria, and decreased GFR were observed in the rats from dams submitted to high-sodium intake before surgery. However, there was no difference in these parameters between the groups after the 5/6 nephrectomy. The scores for tubulointerstitial lesions and glomerulosclerosis were higher in the rats from the sham saline group compared to the same age control rats, but there was no difference in the histological findings between the groups of nephrectomized rats. In conclusion, our data showed that the high-salt intake during pregnancy and lactation in rats leads to structural changes in the kidney of adult offspring. However, the progression of the renal lesions after 5/6 nephrectomy was similar in both groups.

  3. Chylous ascites following radical nephrectomy: a case report

    Directory of Open Access Journals (Sweden)

    Shah Shahzad S

    2008-01-01

    Full Text Available Abstract Introduction Chylous ascites may result from diverse pathologies. Ascites results either due to blockage of the lymphatics or leak secondary to inadvertent trauma during surgery. Case presentation We report the first case of chylous ascites following radical nephrectomy for a renal cell carcinoma involving the right half of a crossed fused renal ectopia. The patient was managed conservatively. Conclusion Post-operative chylous ascites is a rare complication of retroperitoneal and mediastinal surgery. Most cases resolve with conservative treatment which aims at decreasing lymph production and optimizing nutritional requirements along with palliative measures. Refractory cases need either open or laparoscopic ligation of the leaking lymphatic channels. A review of the current literature on the management of post-operative chylous ascites is presented.

  4. Hand-assisted robotic right donor nephrectomy in patient with total sinus inversus: A case report

    Science.gov (United States)

    Gonzalez-Heredia, Raquel; Garcia-Roca, Raquel; Benedetti, Enrico

    2016-01-01

    Total situs inversus” is an infrequent congenital condition. The robot has been already proved as a safe and attractive approach for living donor neprectomies. We report here the first right donor nephrectomy in a patient with total sinus inversus that is performed using the Da Vinci platform. PMID:27085108

  5. Laparoscopic radical nephrectomy: incorporating advantages of hand assisted and standard laparoscopy.

    Science.gov (United States)

    Ponsky, Lee E; Cherullo, Edward E; Banks, Kevin L W; Greenstein, Marc; Streem, Stevan B; Klein, Eric A; Zippe, Craig D

    2003-06-01

    We present an approach to laparoscopic radical nephrectomy and intact specimen extraction, which incorporates hand assisted and standard laparoscopic techniques. A refined approach to laparoscopic radical nephrectomy is described and our experience is reviewed. A low, muscle splitting Gibson incision is made just lateral to the rectus muscle and the hand port is inserted. A trocar is placed through the hand port and pneumoperitoneum is established. With the laparoscope in the hand port trocar 2 additional trocars are placed under direct vision. The laparoscope is then repositioned through the middle trocar and standard laparoscopic instruments are used through the other 2 trocars including the one in the hand port. If at any time during the procedure the surgeon believes the hand would be useful or needed, the trocar is removed from the hand port and the hand is inserted. This approach has been applied to 7 patients. Mean estimated blood loss was 200 cc (range 50 to 300) and mean operative time was 276.7 minutes (range 247 to 360). Mean specimen weight was 767 gm. (range 538 to 1,170). Pathologically 6 specimens were renal cell carcinoma (grades 2 to 4) and 1 was oncocytoma. Mean length of hospital stay was 3.71 days (range 2 to 7). There were no major complications. We believe that this approach enables the surgeon to incorporate the advantages of the hand assisted and standard laparoscopic approaches.

  6. Control of the large renal vein in limited dissected space during laparoscopic nephrectomy: a simple and reliable method

    NARCIS (Netherlands)

    Kijvikai, Kittinut; Laguna, M. Pilar; de la Rosette, Jean

    2006-01-01

    We describe our technique for large renal vein control in the limited dissected space during laparoscopic nephrectomy. This technique is a simple, inexpensive and reliable method, especially for large and short renal vein ligation

  7. The natural history of renal function after surgical management of renal cell carcinoma: Results from the Canadian Kidney Cancer Information System.

    Science.gov (United States)

    Mason, Ross; Kapoor, Anil; Liu, Zhihui; Saarela, Olli; Tanguay, Simon; Jewett, Michael; Finelli, Antonio; Lacombe, Louis; Kawakami, Jun; Moore, Ronald; Morash, Christopher; Black, Peter; Rendon, Ricardo A

    2016-11-01

    Patients who undergo surgical management of renal cell carcinoma (RCC) are at risk for chronic kidney disease and its sequelae. This study describes the natural history of renal function after radical and partial nephrectomy and explores factors associated with postoperative decline in renal function. This is a multi-institutional cohort study of patients in the Canadian Kidney Cancer Information System who underwent partial or radical nephrectomy for RCC. Estimated glomerular filtration rate (eGFR) and stage of chronic kidney disease were determined preoperatively and at 3, 12, and 24 months postoperatively. Linear regression was used to determine the association between postoperative eGFR and type of surgery (radical vs. partial), duration of ischemia, ischemia type (warm vs. cold), and tumor size. With a median follow-up of 26 months, 1,379 patients were identified from the Canadian Kidney Cancer Information System database including 665 and 714 who underwent partial and radical nephrectomy, respectively. Patients undergoing radical nephrectomy had a lower eGFR (mean = 19ml/min/1.73m 2 lower) at 3, 12, and 24 months postoperatively (Prenal function occurred early and remained stable throughout follow-up. A lower preoperative eGFR and increasing age were also associated with a lower postoperative eGFR (P0.05). Severe renal failure (eGFRrenal function remains stable in patients undergoing surgery for RCC. Patients undergoing radical nephrectomy have a greater long-term reduction in renal function compared with those undergoing partial nephrectomy. Ischemia duration and type are not predictive of postoperative renal function when adhering to generally short ischemia durations. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. The assessment of renal cortex and parenchymal volume using automated CT volumetry for predicting renal function after donor nephrectomy.

    Science.gov (United States)

    Mitsui, Yosuke; Sadahira, Takuya; Araki, Motoo; Wada, Koichiro; Tanimoto, Ryuta; Ariyoshi, Yuichi; Kobayashi, Yasuyuki; Watanabe, Masami; Watanabe, Toyohiko; Nasu, Yasutomo

    2018-04-01

    Contrast-enhanced CT is necessary before donor nephrectomy and is usually combined with a Tc-99m-mercapto-acetyltriglycine (MAG3) scan to check split renal function (SRF). However, all transplant programs do not use MAG3 because of its high cost and exposure to radiation. We examined whether CT volumetry of the kidney can be a new tool for evaluating SRF. Sixty-three patients underwent live donor nephrectomy. Patients without a 1.0 mm slice CT or follow-up for volumetry was analyzed at 1, 3, and 12 months post nephrectomy. Strong correlations were observed preoperatively in a Bland-Altman plot between SRF measured by MAG3 and either CT cortex or parenchymal volumetry. In addition, eGFR after donation correlated with SRF measured by MAG3 or CT volumetry. The correlation coefficients (R) for eGFR Mag3 split were 0.755, 0.615, and 0.763 at 1, 3 and 12 months, respectively. The corresponding R values for cortex volume split were 0.679, 0.638, and 0.747. Those for parenchymal volume split were 0.806, 0.592, and 0.764. Measuring kidney by CT volumetry is a cost-effective alternative to MAG3 for evaluating SRF and predicting postoperative donor renal function. Both cortex and parenchymal volumetry were similarly effective.

  9. Icariin protects rats against 5/6 nephrectomy-induced chronic kidney failure by increasing the number of renal stem cells.

    Science.gov (United States)

    Huang, Zhongdi; He, Liqun; Huang, Di; Lei, Shi; Gao, Jiandong

    2015-10-21

    Chronic kidney disease poses a serious health problem worldwide with increasing prevalence and lack of effective treatment. This study aimed to investigate the mechanism of icariin in alleviating chronic renal failure induced by 5/6 nephrectomy in rats. The chronic renal failure model was established by a two-phased 5/6 nephrectomy procedure. The model rats were given daily doses of water or icariin for 8 weeks. The kidney morphology was checked by HE staining. The levels of blood urea nitrogen, serum creatinine, and serum uric acid were measured by colometric methods. The expression of specified genes was analyzed by quantitative real-time PCR and immunohistochemical staining. The number of renal stem/progenitor cells was analyzed by CD133 and CD24 immunohistochemical staining. Icariin protected against CDK-caused damages to kidney histology and improved renal function, significantly reduced levels of BUN, creatinine, and uric acid. Icariin inhibited the expression level of TGF-β1 whereas upregulated HGF, BMP-7, WT-1, and Pax2 expression. Moreover, ccariin significantly increased the expression of CD24, CD133, Osr1, and Nanog in remnant kidney and the numbers of CD133(+)/CD24(+) renal stem/progenitor cells. These data demonstrated that icariin effectively alleviated 5/6 nephrectomy induced chronic renal failure through increasing renal stem/progenitor cells.

  10. Newer techniques of mechanical ventilation: an overview.

    Science.gov (United States)

    Donn, Steven M; Sinha, Sunil K

    2002-10-01

    The introduction of newer, state-of-the-art, microprocessor controlled ventilator systems provides clinicians with opportunities to apply a number of advanced ventilatory modalities which were not previously available for treating newborns. Some of these techniques will need further scientific evaluation in controlled trials, but this should not preclude their use in clinical settings, as their safety has already been proved by "standard setters" for use in neonates. There is a firm physiological rationale for their use, and individual centres have already acquired substantial experience in the application of these modalities. The trend towards increasing sophistication and greater versatility is likely to continue, and clinicians involved in the care of sick newborn infants must keep abreast of these developments.

  11. Mercaptoacetyltriglycine-3 renogram is not superior to estimated glomerular filtration rate measurement for the prediction of long-term renal function after nephrectomy

    International Nuclear Information System (INIS)

    Kanamaru, Hiroshi; Yamamoto, Masakazu; Nagahama, Kanji

    2011-01-01

    The objective of this study was to evaluate the clinical usefulness of effective renal plasma flow (ERPF) measured using preoperative mercaptoacetyltriglycine-3 (MAG3) renogram for the prediction of chronic renal insufficiency after nephrectomy. A total of 47 patients underwent preoperative MAG3 renal scintigraphy and subsequent unilateral nephrectomy. Correlations between the 5-year postoperative estimated glomerular filtration rate (eGFR) and the preoperative ERPF of the contralateral kidney (cERPF), ERPF of the diseased kidney (dERPF), total ERPF (tERPF), cERPF to dERPF ratio, serum creatinine (sCr) level, eGFR, as well as the influence of preoperative comorbidities (diabetes, hypertension) on the postoperative eGFR, were evaluated with both univariate and multivariate analyses. Multiple linear regression analysis showed that preoperative cERPF significantly correlated with postoperative eGFR. However, a much stronger correlation was observed between the preoperative and postoperative eGFR. Multiple logistic regression analysis showed that only preoperative eGFR was a significant predicator of the development of advanced-stage chronic kidney disease (CKD). Preoperative MAG3 renogram is not superior to eGFR measurement as a prognostic indicator of long-term renal function after unilateral nephrectomy. (author)

  12. TORPEDO: Prospective, double blind, randomized clinical trial comparing the use of Ketorolac verse placebo during live donor nephrectomy for kidney transplant

    Directory of Open Access Journals (Sweden)

    Jeffrey Campsen

    2017-06-01

    Full Text Available The aim of this pilot study was to determine if the use of Ketorolac for donor nephrectomies could decrease the use of narcotics. Methods: This is a prospective, double blind, randomized trial involving patients undergoing nephrectomy for live donor kidney transplantation. Three arms: 1. Ketorolac 30 mg IV×1 in the OR, then ketorolac 15 mg IV every 6 h for 7 doses. 2. Ketorolac 30 mg IV×1 in the OR, then placebo IV every 6 h for 7 doses. 3. Placebo IV×1 in the OR, then placebo IV every 6 h for 7 doses. Outcomes: blood loss, mortality, renal function, cumulative narcotic use, length of hospital stay (LOS, and urinary retention. Results: There were no patient deaths, blood transfusions or renal dysfunction in any study arm. Arm 1 had less narcotic use, reduced length of stay, and reduced urinary retention than Arm 3. Conclusion: There was reduced LOS, less narcotic use and less urinary retention in the Ketorolac group (Arm 1 versus the placebo group (Arm 3. Based on these results we will proceed with a larger study to compare the use of non-opioid analgesics in donor nephrectomies.

  13. 45 CFR 170.455 - Testing and certification to newer versions of certain standards.

    Science.gov (United States)

    2010-10-01

    ... INFORMATION TECHNOLOGY HEALTH INFORMATION TECHNOLOGY STANDARDS, IMPLEMENTATION SPECIFICATIONS, AND CERTIFICATION CRITERIA AND CERTIFICATION PROGRAMS FOR HEALTH INFORMATION TECHNOLOGY Temporary Certification Program for HIT § 170.455 Testing and certification to newer versions of certain standards. (a) ONC-ATCBs...

  14. Follow the light: projector-based augmented reality intracorporeal system for laparoscopic surgery.

    Science.gov (United States)

    Edgcumbe, Philip; Singla, Rohit; Pratt, Philip; Schneider, Caitlin; Nguan, Christopher; Rohling, Robert

    2018-04-01

    A projector-based augmented reality intracorporeal system (PARIS) is presented that includes a miniature tracked projector, tracked marker, and laparoscopic ultrasound (LUS) transducer. PARIS was developed to improve the efficacy and safety of laparoscopic partial nephrectomy (LPN). In particular, it has been demonstrated to effectively assist in the identification of tumor boundaries during surgery and to improve the surgeon's understanding of the underlying anatomy. PARIS achieves this by displaying the orthographic projection of the cancerous tumor on the kidney's surface. The performance of PARIS was evaluated in a user study with two surgeons who performed 32 simulated robot-assisted partial nephrectomies. They performed 16 simulated partial nephrectomies with PARIS for guidance and 16 simulated partial nephrectomies with only an LUS transducer for guidance. With PARIS, there was a significant reduction [30% ([Formula: see text])] in the amount of healthy tissue excised and a trend toward a more accurate dissection around the tumor and more negative margins. The combined point tracking and reprojection root-mean-square error of PARIS was 0.8 mm. PARIS' proven ability to improve key metrics of LPN surgery and qualitative feedback from surgeons about PARIS supports the hypothesis that it is an effective surgical navigation tool.

  15. Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects.

    Science.gov (United States)

    Mota Filho, Francisco Hidelbrando Alves; Sávio, Luis Felipe; Sakata, Rafael Eiji; Ivanovic, Renato Fidelis; da Silva, Marco Antonio Nunes; Maia, Ronaldo; Passerotti, Carlo

    2018-01-01

    Robot-Assisted Single Site Radical Nephrectomy (RASS-RN) has been reported by surgeons in Europe and United States (1-3). To our best knowledge this video presents the first RASS-RN with concomitant cholecystectomy performed in Latin America. A 66 year-old renal transplant male due to chronic renal failure presented with an incidental 1.3cm nodule in the upper pole of the right kidney. In addition, symptomatic gallbladder stones were detected. Patient was placed in modified flank position. Multichannel single port device was placed using Hassan's technique through a 3cm supra-umbilical incision. Standard radical nephrectomy and cholecystectomy were made using na 8.5mm camera, two 5mm robotic arms and an assistant 5mm access. Surgery time and estimated blood loss were 208 minutes and 100mL, respectively. Patient did well and was discharged within less than 48 hours, without complications. Pathology report showed benign renomedullary tumor of interstitial cells and chronic cholecystitis. Robotic technology improves ergonomics, gives better precision and enhances ability to approach complex surgeries. Robot-assisted Single Port aims to reduce the morbidity of multiple trocar placements while maintaining the advantages of robotic surgery (2). Limitations include the use of semi-rigid instruments providing less degree of motion and limited space leading to crash between instruments. On the other hand, it is possible to perform complex and concomitant surgeries with just one incision. RASS-RN seems to be safe and feasible option for selected cases. Studies should be performed to better understand the results using single port technique in Urology. Copyright® by the International Brazilian Journal of Urology.

  16. Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects

    Directory of Open Access Journals (Sweden)

    Francisco Hidelbrando Alves Mota Filho

    Full Text Available ABSTRACT Introduction Robot-Assisted Single Site Radical Nephrectomy (RASS-RN has been reported by surgeons in Europe and United States (1–3. To our best knowledge this video presents the first RASS-RN with concomitant cholecystectomy performed in Latin America. Case A 66 year-old renal transplant male due to chronic renal failure presented with an incidental 1.3cm nodule in the upper pole of the right kidney. In addition, symptomatic gallbladder stones were detected. Results Patient was placed in modified flank position. Multichannel single port device was placed using Hassan's technique through a 3 cm supra-umbilical incision. Standard radical nephrectomy and cholecystectomy were made using an 8.5mm camera, two 5mm robotic arms and an assistant 5mm access. Surgery time and estimated blood loss were 208 minutes and 100mL, respectively. Patient did well and was discharged within less than 48 hours, without complications. Pathology report showed benign renomedullary tumor of interstitial cells and chronic cholecystitis. Discussion Robotic technology improves ergonomics, gives better precision and enhances ability to approach complex surgeries. Robot-assisted Single Port aims to reduce the morbidity of multiple trocar placements while maintaining the advantages of robotic surgery (2. Limitations include the use of semi-rigid instruments providing less degree of motion and limited space leading to crash between instruments. On the other hand, it is possible to perform complex and concomitant surgeries with just one incision. Conclusion RASS-RN seems to be safe and feasible option for selected cases. Studies should be performed to better understand the results using single port technique in Urology.

  17. Negative pressure wound therapy for partial-thickness burns.

    Science.gov (United States)

    Dumville, Jo C; Munson, Christopher; Christie, Janice

    2014-12-15

    A burn wound is a complex and evolving injury, with both local and systemic consequences. Burn treatments include a variety of dressings, as well as newer strategies, such as negative pressure wound therapy (NPWT), which, by means of a suction force that drains excess fluids from the burn, tries to promote the wound healing process and minimise progression of the burn wound. To assess the effectiveness of NPWT for people with partial-thickness burns. We searched the Cochrane Wounds Group Specialised Register (searched 04 September 2014); The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2014, Issue 8). All randomised controlled trials (RCTs) and controlled clinical trials (CCTs) that evaluated the safety and effectiveness of NPWT for partial-thickness burns. Two review authors used standardised forms, and extracted the data independently. We assessed each trial for risk of bias, and resolved differences by discussion. One RCT, that was an interim report, satisfied the inclusion criteria. We undertook a narrative synthesis of results, as the absence of data and poor reporting precluded us from carrying out any formal statistical analysis. The trial was at high risk of bias. There was not enough evidence available to permit any conclusions to be drawn regarding the use of NPWT for treatment of partial-thickness burn wounds.

  18. Laparoscopic nephrectomy for a single-system ectopic ureter draining a small, dysplastic and poorly functioning kidney in children

    International Nuclear Information System (INIS)

    Jeong, Byong-Chang; Lim, Dae-Jung; Lee, Sang-Chul; Choi, Hwang; Kim, Hyeon-Hoe

    2007-01-01

    The purpose of this study was to assess the efficacy of laparoscopic nephrectomy for a single-system ectopic ureter draining a dysplastic kidney in children. Between February 1999 and September 2005, 16 girls with a mean age of 6.2 years (range: 2-15 years) presented with urinary incontinence accompanied by regular voiding since birth (15 patients) and vaginitis (one patient). Ultrasonography, intravenous urography and a technetium-99m dimercaptosuccinic acid ( 99m Tc-DMSA) renal scan showed the presence of only a single kidney in all cases. Computed tomography (CT) showed a dysplastic kidney definitely in nine patients, structures suspicious of dysplastic kidney in three cases, and no dysplastic kidney in four cases. Magnetic resonance imaging was carried out in the four cases with non-visualized dysplastic kidneys by CT, and showed a suspicious lesion in only one case, and no lesion in the other three patients. All patients underwent transperitoneal laparoscopic nephrectomy for a dysplastic kidney. Laparoscopy identifies all dysplastic kidneys easily, even in those cases in which dystrophic kidney could not be identified by preoperative imaging. Dysplastic kidneys and ectopic ureters were removed successfully in all 16 patients. Mean operative time was 109 min (range: 40-155 min) with little intraoperative bleeding. Mean postoperative hospital stay was 2.6 days (range: 2-4 days). No intraoperative complication was encountered, except in one single case, in which a small bowel injury occurred during open Hasson's procedure. All patients became dry soon after the operation. Laparoscopic nephrectomy for an ectopic ureter draining into a dysplastic kidney is a safe and effective method, and can be carried out successfully, despite a failure by preoperative imaging studies to localize the dysplastic kidney. (author)

  19. Oncological outcomes of laparoscopic radical nephrectomy for renal cancer Resultados oncológicos da nefrectomia radical laparoscópica no tratamento do carcinoma renal

    Directory of Open Access Journals (Sweden)

    Jose R. Colombo Jr.

    2007-01-01

    Full Text Available PURPOSE: To report the 5-year oncological outcomes of patients undergoing laparoscopic radical nephrectomy for renal cancer compared to a cohort of patients undergoing open radical nephrectomy. METHODS: We retrospectively analyzed the data of 88 patients undergoing radical nephrectomy for renal cell carcinoma prior to January 2000. Of these, 45 patients underwent laparoscopic radical nephrectomy, and 43 patients underwent open radical nephrectomy. Inclusion criteria comprised clinically organ-confined tumors of 15 cm or less in size without concomitant lymphadenopathy or vena cava thrombus. Oncological follow-up data were obtained from charts, radiological reports, and phone calls to patients or their families, and were calculated from the date of surgery to the date of last appointment with physician or date of death. RESULTS: All laparoscopic procedures were completed without open conversion. On comparing the laparoscopic radical nephrectomy and open radical nephrectomy groups, mean tumor size was 5. 8 vs 6.2 cm (P = . 44, mean blood loss was 183 vs 461 mL (P = . 004, and mean operative time was 2.8 vs 3.7 hrs (P OBJETIVO: Relatar os resultados oncológicos após 5 anos de seguimento em pacientes submetidos a nefrectomia radical laparoscópica para tratamento do câncer renal, comparando esses com os resultados obtidos com um grupo de pacientes submetidos a nefrectomia radical aberta. MÉTODOS: Foram analisadas retrospectivamente as informações obtidas de 88 pacientes submetidos a nefrectomia radical para o tratamento do carcinoma renal realizadas previamente a Janeiro de 2000. Destes pacientes, 45 foram tratados com nefrectomia radical laparoscópica e 43 com nefrectomia radical aberta. Foram incluídos pacientes com tumores localizados com tamanho máximo de 15 cm, sem adenopatia ou sinal de envolvimento de veia renal na avaliação radiologica pré-operatória. As informações sobre o seguimento dos pacientes foram obtidas a partir de

  20. Radiation protection in newer imaging technologies

    International Nuclear Information System (INIS)

    Rehani, M. M.

    2010-01-01

    Not even a week passes without a paper getting published in peer reviewed journals on radiation protection in newer imaging technologies that either did not exist 10 y ago or were not established for routine use. Computed tomography (CT) happens to be a common element in most of these technologies. Radiation protection is high on the agenda of manufacturers and researchers and that is becoming a driving force for users and international organisations. The media and thus the public have their own share in increasing the momentum. The slice war seems to be shifting to dose war. Manufacturers are now chasing the target of sub-mSv CT. The era of two digit mSv effective dose for a CT procedure is far from losing ground, although cardiac CT within 5 mSv seems possible. A few years ago the change in technology was faster than adoption of dose management but currently even the development of dose reduction techniques is faster than its adoption. There is dearth of large scale surveys of practice and lack of surveys with change in technology. (authors)

  1. Adverse drug reaction monitoring of newer oral anti diabetic drugs – a pharmacovigilance perspective

    Directory of Open Access Journals (Sweden)

    Ankita Bhattacharjee

    2016-04-01

    Full Text Available Objective: To monitor and evaluate adverse drug reactions (ADRs of newer oral anti-diabetic drugs in type II diabetics by spontaneous/solicited ADR monitoring.Material and methods: Two hundred and thirty two diabetic patients on newer oral antidiabetic drugs were evaluated prospectively in a cross-sectional study over a period of eighteen months. All patients were followed up for ADRs which were evaluated for incidence, frequency, severity and causality. ADR severity was graded according to University of Virginia Health System Adverse Drug Reaction Reporting program criteria and causality assessment was done using WHO-UMC scale.Results: 190 out of 232 patients (42 patients lost to follow up were evaluated. ADRs were observed in 34 cases (17.9%. Most common ADRs were gastrointestinal (44.2% followed by musculoskeletal (17.6%, metabolic (14.7%, infections (5.9% and others (17.6%. The maximal frequency of ADRs was seen with sitagliptin (6.4% followed by vildagliptin(3.8%, saxagliptin(2.7%, saroglitazar(2.1%, linagliptin(1.6%, canagliflozin(1.6%. 25(73.5%, 8(23.5% and 1(3% ADRs were mild, moderate and severe respectively. 24(70% ADRs were classified as possible, 9(27% probable and 1(3% unlikely on causality assessment. Conclusion: Newer oral antidiabetic drugs like gliptins and SGLT-2 inhibitors have potential to cause ADRs. Gastro-intestinal, musculoskeletal, metabolic were most common ADRs. Active pharmacovigilance should be carried out for risk identification and management. 

  2. Melanotic Xp11 Translocation Renal Cancer Managed With Radical Nephrectomy and IVC Tumor Thrombectomy

    Directory of Open Access Journals (Sweden)

    Iyad S. Khourdaji

    2017-01-01

    Full Text Available Melanotic Xp11 translocation renal cancer is a rarely observed neoplasm primarily affecting adolescents and young adults. Given the paucity of data describing this malignancy, its natural history and subsequent long-term management are not well understood. We report a case of melanotic Xp11 translocation with tumor thrombus extension managed with radical nephrectomy and inferior vena cava (IVC tumor thrombectomy. To our knowledge, this is the first case report to describe use of conventional tumor thrombectomy techniques in a patient with melanotic Xp11 translocation renal cancer.

  3. Reducing Operating Room Costs Through Real-Time Cost Information Feedback: A Pilot Study.

    Science.gov (United States)

    Tabib, Christian H; Bahler, Clinton D; Hardacker, Thomas J; Ball, Kevin M; Sundaram, Chandru P

    2015-08-01

    To create a protocol for providing real-time operating room (OR) cost feedback to surgeons. We hypothesize that this protocol will reduce costs in a responsible way without sacrificing quality of care. All OR costs were obtained and recorded for robot-assisted partial nephrectomy and laparoscopic donor nephrectomy. Before the beginning of this project, costs pertaining to the 20 most recent cases were analyzed. Items were identified from previous cases as modifiable for replacement or omission. Timely feedback of total OR costs and cost of each item used was provided to the surgeon after each case, and costs were analyzed. A cost analysis of the robot-assisted partial nephrectomy before the washout period indicates expenditures of $5243.04 per case. Ten recommended modifiable items were found to have an average per case cost of $1229.33 representing 23.4% of the total cost. A postwashout period cost analysis found the total OR cost decreased by $899.67 (17.2%) because of changes directly related to the modifiable items. Therefore, 73.2% of the possible identified savings was realized. The same stepwise approach was applied to laparoscopic donor nephrectomies. The average total cost per case before the washout period was $3530.05 with $457.54 attributed to modifiable items. After the washout period, modifiable items costs were reduced by $289.73 (8.0%). No complications occurred in the donor nephrectomy cases while one postoperative complication occurred in the partial nephrectomy group. Providing surgeons with feedback related to OR costs may lead to a change in surgeon behavior and decreased overall costs. Further studies are needed to show equivalence in patient outcomes.

  4. Comparative Study of the Effect of Intravenous Paracetamol and Tramadol in Relieving of Postoperative Pain after General Anesthesia in Nephrectomy Patients.

    Science.gov (United States)

    Manne, Venkata Sesha Sai Krishna; Gondi, Srinivasa Rao

    2017-01-01

    The aim of this study was to compare the effect of intravenous paracetamol and tramadol in relieving of postoperative pain after general anesthesia for nephrectomy in prospective donor patients for kidney transplantation. A randomized study was conducted on 100 adult patients scheduled for nephrectomy aged from 35 to 55 years of both sexes and divided into two groups and were administered intravenous paracetamol and tramadol for postoperative pain relief and assessed with visual analog scale score and variations in vital parameters to assess extent of pain relief. After statistical interpretation of collected data, the observations were extrapolated. There was a statistically significant difference in the pain intensity scores obtained between the paracetamol and tramadol groups. On the basis of the present study, it is concluded that tramadol due to its lesser onset of action time was superior to paracetamol in providing acute postoperative pain relief.

  5. Cost effectiveness of open versus laparoscopic living-donor nephrectomy

    DEFF Research Database (Denmark)

    Hamidi, Vida; Andersen, Marit Helen; Oyen, Ole

    2009-01-01

    , and a consequent potential to increase the pool of kidney donors. However, the cost effectiveness of LLDN remains unknown. The aim of this study was to explore the health and cost consequences of replacing open-donor nephrectomy by LLDN. METHODS: Kidney donors were randomized to laparoscopic (n=63) or open surgery...... (n=59). We obtained data on operating time, personnel costs, length of stay, cost of analgesic, disposable instruments and complications, and indirect costs. Quality of life was captured before the operation and at 1, 6, and 12 months postdonation by means of short form-36. The scores were translated...... into utilities by means of Brazier's 6D algorithm. RESULTS: The cost per patient was U.S. $55,292 with laparoscopic and U.S. $29,886 with open surgery. The greatest cost difference was in costs attributed to complications (U.S. $33,162 vs. U.S. $4,573). The 1-year quality-adjusted life years (QALYs) were 0...

  6. Newer treatments for fibromyalgia syndrome

    Directory of Open Access Journals (Sweden)

    Richard E Harris

    2008-12-01

    Full Text Available Richard E Harris, Daniel J ClauwDepartment of Anesthesiology, The University of Michigan, Ann Arbor, MI, USAAbstract: Fibromyalgia syndrome is a common chronic pain disorder of unknown etiology. The lack of understanding of the pathophysiology of fibromyalgia has made this condition frustrating for patients and clinicians alike. The most common symptoms of this disorder are chronic widespread pain, fatigue, sleep disturbances, difficulty with memory, and morning stiffness. Emerging evidence points towards augmented pain processing within the central nervous system (CNS as having a primary role in the pathophysiology of this disorder. Currently the two drugs that are approved by the United States Food and Drug Administration (FDA for the management of fibromyalgia are pregabalin and duloxetine. Newer data suggests that milnacipran, a dual norepinephrine and serotonin reuptake inhibitor, may be promising for the treatment of fibromyalgia. A double-blind, placebo-controlled trial of milnacipran in 125 fibromyalgia patients showed significant improvements relative to placebo. Milnacipran given either once or twice daily at doses up to 200 mg/day was generally well tolerated and yielded significant improvements relative to placebo on measures of pain, patient’s global impression of change in their disease state, physical function, and fatigue. Future studies are needed to validate the efficacy of milnacipran in fibromyalgia.Keywords: fibromyalgia, pain, pharmacological, treatment

  7. Provider-based research networks and diffusion of surgical technologies among patients with early-stage kidney cancer.

    Science.gov (United States)

    Tan, Hung-Jui; Meyer, Anne-Marie; Kuo, Tzy-Mey; Smith, Angela B; Wheeler, Stephanie B; Carpenter, William R; Nielsen, Matthew E

    2015-03-15

    Provider-based research networks such as the National Cancer Institute's Community Clinical Oncology Program (CCOP) have been shown to facilitate the translation of evidence-based cancer care into clinical practice. This study compared the utilization of laparoscopy and partial nephrectomy among patients with early-stage kidney cancer according to their exposure to CCOP-affiliated providers. With linked Surveillance, Epidemiology, and End Results-Medicare data, patients with T1aN0M0 kidney cancer who had been treated with nephrectomy from 2000 to 2007 were identified. For each patient, the receipt of care from a CCOP physician or hospital and treatment with laparoscopy or partial nephrectomy were determined. Adjusted for patient characteristics (eg, age, sex, and marital status) and other organizational features (eg, community hospital and National Cancer Institute-designated cancer center), multivariate logistic regression was used to estimate the association between each surgical innovation and CCOP affiliation. During the study interval, 1578 patients (26.8%) were treated by a provider with a CCOP affiliation. Trends in the utilization of laparoscopy and partial nephrectomy remained similar between affiliated and nonaffiliated providers (P ≥ .05). With adjustments for patient characteristics, organizational features, and clustering, no association was noted between CCOP affiliation and the use of laparoscopy (odds ratio [OR], 1.11; 95% confidence interval [CI], 0.81-1.53) or partial nephrectomy (OR, 1.04; 95% CI, 0.82-1.32) despite the more frequent receipt of these treatments in academic settings (P kidney cancer, indicating perhaps a more limited scope to provider-based research networks as they pertain to translational efforts in cancer care. © 2014 American Cancer Society.

  8. Comparative clinical evaluation of removable partial dentures made of two different materials in Kennedy Applegate class II partially edentulous situation.

    Science.gov (United States)

    Hundal, Maninder; Madan, Rajesh

    2015-12-01

    Cast Chromium Cobalt alloy has been the material of choice for fabricating Removable Partial Dentures (RPDs) but has certain drawbacks. Newer materials like the flexible Nylon based Super Polyamide have been introduced to overcome these drawbacks. The present study has compared the above two materials for nine clinical parameters. The study was carried out on 30 patients presenting with a Kennedy Applegate class II partially edentulous situation who were divided into two equal groups and clinically assessed. Statistically significant results were obtained in favor of flexible RPDs, in the parameters of 'aesthetics' and 'overall patient satisfaction'. Both groups showed more or less similar values for 'frequency of fracture of the prosthesis during usage' with the incidence being slightly higher for patients wearing the cast RPDs. The clinical parameters of 'oral soft tissue tolerance', 'gingival health', 'periodontal health' and 'adaptability in areas with undercut' were statistically at par for all the 30 patients thus suggesting the comparable biocompatibility of the two materials. The highlight of this study was the relative ease in fabrication of the flexible RPDs as compared to the cast RPDs. Based on the favorable clinical results of this study, it can be summarized that the flexible RPDs is a viable alternative to cast RPDs in Kennedy Applegate class II partially edentulous situation in the short term.

  9. MDCT evaluation of potential living renal donor, prior to laparoscopic donor nephrectomy: What the transplant surgeon wants to know?

    International Nuclear Information System (INIS)

    Ghonge, Nitin P; Gadanayak, Satyabrat; Rajakumari, Vijaya

    2014-01-01

    As Laparoscopic Donor Nephrectomy (LDN) offers several advantages for the donor such as lesser post-operative pain, fewer cosmetic concerns and faster recovery time, there is growing global trend towards LDN as compared to open nephrectomy. Comprehensive pre-LDN donor evaluation includes assessment of renal morphology including pelvi-calyceal and vascular system. Apart from donor selection, evaluation of the regional anatomy allows precise surgical planning. Due to limited visualization during laparoscopic renal harvesting, detailed pre-transplant evaluation of regional anatomy, including the renal venous anatomy is of utmost importance. MDCT is the modality of choice for pre-LDN evaluation of potential renal donors. Apart from appropriate scan protocol and post-processing methods, detailed understanding of surgical techniques is essential for the Radiologist for accurate image interpretation during pre-LDN MDCT evaluation of potential renal donors. This review article describes MDCT evaluation of potential living renal donor, prior to LDN with emphasis on scan protocol, post-processing methods and image interpretation. The article laid special emphasis on surgical perspectives of pre-LDN MDCT evaluation and addresses important points which transplant surgeons want to know

  10. Health effects of Chernobyl: newer perspectives

    International Nuclear Information System (INIS)

    Desai, Usha

    1996-01-01

    On the 26th of April 1986, the 4th unit of the Chernobyl Nuclear Power Plant in the former Soviet Union exploded, following a scheduled but not-well-planned testing of a turbo-generator prior to a shutdown of the reactor. This led to a release of large amounts of radioactive material into the atmosphere, resulting in a cloud not only over in the Soviet Union, but due to prevailing meteorological condition, over the Eastern Europe as well. Over the past ten years, a large number of agencies in the areas of human health and hygiene, agriculture and veterinary sciences in addition to those involved in radiation protection and radiation safety have studied the impact of the accident. These studies were also extended to evaluate and mitigate the consequences. The accident has been a warning, and has provided lessons in mitigating the consequences of any industrial accident. Newer perspectives have emerged in the area of early diagnosis and treatment of the acute effects of radiation. Research in the areas of genetics, molecular biology and radiation biology will contribute to better medical care in future. (author). 3 tabs

  11. Laparoscopic resection of tumor recurrence after radical nephrectomy for localized renal cell carcinoma.

    Science.gov (United States)

    Curcio, Lessandro; Cunha, Antonio Claudio; Renteria, Juan; Presto, Daniel

    2014-01-01

    Local recurrence of Renal Cell Carcinoma (RCC) after radical nephrectomy is a rare event. Some known risk factors are: clinical/pathological stage, locorregional disease and lyimph node positivity. Since up to 30-40% of patients can achieve a disease-free status, we show a case (video) in which we performed a laparoscopic excision of a local RCC, taking advantage of all the well-known benefits of laparoscopy. A 56 years old female with a history of open radical nephrectomy two years before was diagnosed with a mass at the time of surveillance CT imaging during follow-up. The suspected local recurrence was 12 cm, and vascularized predominantly by tributaries originating from the iliac vessels. There was no other site of disease (i.e. brain, lung, liver, bones) and laboratory tests were normal. Laparoscopic approach was approached, by inserting 4 trocars (2 of 10 and 2 of 5mm) with the patient in the lateral position. The procedure lasted 130 minutes, with 220 mL of estimated bleeding; the larger vessels were ligated with polymer clips (Hem-o-lok) and the smaller handled by ultrasonic clamp. The specimen was removed by a small incision below the umbilicus in an appropriate bag. The patient was feed in the first postoperative day and discharged on the third day. Histopathology revealed sarcoma, with a high degree of mitosis, and negative surgical margins. She was referred to medical oncology for adjuvant therapy consideration. The laparoscopic resection of recurrent tumor should be encouraged in highly selected cases. The minimally invasive method, with its known advantages, especially for more debilitated patients, can be advantageous when applied to suitable cases.

  12. Use of newer technologies with existing service for family reintegration of unknown psychiatric patients: A case series.

    Science.gov (United States)

    Gowda, Guru S; Telang, Ashay; Sharath, Chandra Reddy; Issac, Thomas Gregor; Haripriya, Chintala; Ramu, Praveen Shivalli; Math, Suresh Bada

    2017-10-29

    Homeless Mentally Ill (HMI) patients pose a challenge in treatment, management and rehabilitation services. HMI patients are often difficult to engage in treatment, and associated with relapse and rehospitalization, even after recovery. Family plays an important role in treatment engagement and care of the mentally ill person in India. Here, we report two unknown psychiatric patients who were reintegrated to their families using newer technologies with existing service. Newer technologies have helped in early identification of HMI families and reintegration into them. The early reintegration reduced the unnecessary detention of HMI patients inside the hospital after recovery. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Marginal leakage of two newer glass-ionomer-based sealant materials assessed using micro-CT.

    NARCIS (Netherlands)

    Chen, X.; Cuijpers, V.M.J.I.; Fan, M.; Frencken, J.E.F.M.

    2010-01-01

    OBJECTIVES: To test newer glass-ionomer-based materials as sealant materials. One glass-ionomer sealant was light-cured to obtain an early setting reaction. The null-hypothesis tested was: there is no difference in marginal leakage of sealants produced with high-viscosity glass-ionomer, with and

  14. Chronic granulomatous disease: Value of the newer imaging modalities

    International Nuclear Information System (INIS)

    Stricof, D.D.; Glazer, M.; Amendola, A.

    1984-01-01

    The contribution of computed tomography (CT), ultrasound (US), and nuclear medicine studies in the evaluation and management of seven patients with chronic granulatous disease was retrospectively reviewed. These modalities proved valuable in detecting sites of infection, particularly in the abdomen. Three patients had liver abscesses, two had suppurative retroperitoneal lymphadenopathy, one had empyema, and one hand a scrotal abscess. Furthermore, CT or US-guided percutaneous aspiration and/or drainage of infected material was successfully performed on three separate occasions in a single patient, obviating the need for surgery. The newer imaging modalities are useful in the prompt diagnosis and in some instances non-operative therapy of complications of chronic granulomatous disease. (orig.)

  15. Economics of long-distance transmission, storage, and distribution of heat from nuclear plants with existing and newer techniques

    International Nuclear Information System (INIS)

    Margen, P.H.

    1978-01-01

    Conventional and newer types of hot-water pipes are applied to the bulk transport of reject heat from central nuclear power plants to the district heating network of cities or groups of cities. With conventional pipes, the transport of 300 to 2000 MW of heat over distances of 30 to 100 km can be justified, while with newer pipe types, even longer distances would often be economic. For medium-size district heating schemes, low-temperature heat transport from simple heat-only reactors suitable for closer location to cities is of interest. For daily storage of heat on district heating systems, steel heat accumulators are currently used in Sweden. The development of more advanced cheaper heat accumulators, such as lake storage schemes, could make even seasonal heat storage economic. Newer distribution technology extends the economic field of penetration of district heating even to suburban one-family house districts. With proper design and optimization, nuclear district heating can be competitive in a wide market and achieve very substantial fossil-fuel savings

  16. Idiopathic Non-Cirrhotic Intrahepatic Portal Hypertension (NCIPH)—Newer Insights into Pathogenesis and Emerging Newer Treatment Options

    Science.gov (United States)

    Goel, Ashish; Elias, Joshua E.; Eapen, Chundamannil E.; Ramakrishna, Banumathi; Elias, Elwyn

    2014-01-01

    Chronic microangiopathy of portal venules results in idiopathic non-cirrhotic intrahepatic portal hypertension (NCIPH). Recent data suggest a role for vasoactive factors of portal venous origin in the pathogenesis of this ‘pure’ vasculopathy of the liver. Enteropathies (often silent), are an important ‘driver’ of this disease. NCIPH is under-recognized and often mis-labeled as cryptogenic cirrhosis. Liver biopsy is needed to prove the diagnosis of NCIPH. In these patients, with advancing disease and increased porto-systemic shunting, the portal venous vasoactive factors bypass the liver filter and contribute to the development of pulmonary vascular endothelial disorders—porto-pulmonary hypertension and hepato-pulmonary syndrome as well as mesangiocapillary glomerulonephritis. Prognosis in NCIPH patients is determined by presence, recognition and management of associated disorders. With better understanding of the pathogenesis of NCIPH, newer treatment options are being explored. Imbalance in ADAMTS 13 (a disintegrin and metalloprotease with thrombospondin type 1 motif, member 13): vWF (von-Willebrand factor) ratio is documented in NCIPH patients and may have a pathogenic role. Therapeutic interventions to correct this imbalance may prove to be important in the management of NCIPH. PMID:25755567

  17. Adjuvant Sunitinib in High-Risk Renal-Cell Carcinoma after Nephrectomy.

    Science.gov (United States)

    Ravaud, Alain; Motzer, Robert J; Pandha, Hardev S; George, Daniel J; Pantuck, Allan J; Patel, Anup; Chang, Yen-Hwa; Escudier, Bernard; Donskov, Frede; Magheli, Ahmed; Carteni, Giacomo; Laguerre, Brigitte; Tomczak, Piotr; Breza, Jan; Gerletti, Paola; Lechuga, Mariajose; Lin, Xun; Martini, Jean-Francois; Ramaswamy, Krishnan; Casey, Michelle; Staehler, Michael; Patard, Jean-Jacques

    2016-12-08

    Sunitinib, a vascular endothelial growth factor pathway inhibitor, is an effective treatment for metastatic renal-cell carcinoma. We sought to determine the efficacy and safety of sunitinib in patients with locoregional renal-cell carcinoma at high risk for tumor recurrence after nephrectomy. In this randomized, double-blind, phase 3 trial, we assigned 615 patients with locoregional, high-risk clear-cell renal-cell carcinoma to receive either sunitinib (50 mg per day) or placebo on a 4-weeks-on, 2-weeks-off schedule for 1 year or until disease recurrence, unacceptable toxicity, or consent withdrawal. The primary end point was disease-free survival, according to blinded independent central review. Secondary end points included investigator-assessed disease-free survival, overall survival, and safety. The median duration of disease-free survival was 6.8 years (95% confidence interval [CI], 5.8 to not reached) in the sunitinib group and 5.6 years (95% CI, 3.8 to 6.6) in the placebo group (hazard ratio, 0.76; 95% CI, 0.59 to 0.98; P=0.03). Overall survival data were not mature at the time of data cutoff. Dose reductions because of adverse events were more frequent in the sunitinib group than in the placebo group (34.3% vs. 2%), as were dose interruptions (46.4% vs. 13.2%) and discontinuations (28.1% vs. 5.6%). Grade 3 or 4 adverse events were more frequent in the sunitinib group (48.4% for grade 3 events and 12.1% for grade 4 events) than in the placebo group (15.8% and 3.6%, respectively). There was a similar incidence of serious adverse events in the two groups (21.9% for sunitinib vs. 17.1% for placebo); no deaths were attributed to toxic effects. Among patients with locoregional clear-cell renal-cell carcinoma at high risk for tumor recurrence after nephrectomy, the median duration of disease-free survival was significantly longer in the sunitinib group than in the placebo group, at a cost of a higher rate of toxic events. (Funded by Pfizer; S-TRAC Clinical

  18. Anaesthetic management of a patient with deep brain stimulation implant for radical nephrectomy

    Directory of Open Access Journals (Sweden)

    Monica Khetarpal

    2014-01-01

    Full Text Available A 63-year-old man with severe Parkinson′s disease (PD who had been implanted with deep brain stimulators into both sides underwent radical nephrectomy under general anaesthesia with standard monitoring. Deep brain stimulation (DBS is an alternative and effective treatment option for severe and refractory PD and other illnesses such as essential tremor and intractable epilepsy. Anaesthesia in the patients with implanted neurostimulator requires special consideration because of the interaction between neurostimulator and the diathermy. The diathermy can damage the brain tissue at the site of electrode. There are no standard guidelines for the anaesthetic management of a patient with DBS electrode in situ posted for surgery.

  19. Newer antiatherosclerosis treatment strategies.

    Science.gov (United States)

    Aggarwal, Amitesh; Singh, Safal

    2011-01-01

    Atherosclerosis has been a target of much clinical and molecular research. As a result of this extensive research, it is amply clear that atherogenesis is a multifactorial process involving an interplay of metabolic, immune and inflammatory mechanisms. Antiatherosclerotic strategies are today aiming for a multipronged approach targeting each arm of this multifactorial process. The newer agents under development can be divided into three broad categories: anti-inflammatory agents, modulators of intermediary metabolism and antiatherosclerosis vaccines. Potential targets for anti-inflammatory agents include inhibition of conversion of low-density lipoprotein (LDL) to oxidised LDL, blocking or downregulation of cell adhesion molecules, chemokine modulation and macrophage receptor blockade. Beyond inhibition of plaque formation, efforts are also ongoing to develop agents which stabilise the plaque by increasing its fibrous content and inhibiting its disruption. So far as research in the sphere of intermediary metabolism is concerned, the focus is now primarily on raising high-density lipoprotein and promoting reverse cholesterol transport; potential targets include cholesteryl ester transfer protein, liver X-receptor, lecithin cholesterol acyltransferase and high-density lipoprotein mimetics. Acyl-coenzymeA: cholesterol acyltransferase is another enzyme whose selective and differential inhibition is under active investigation. The concept of immunisation against a non-communicable disease such as atherosclerosis is still in its nascent stages. However, with increasing evidence to suggest the role of antigen-specific T-cell-mediated immunity in atherogenesis, this approach is potentially promising. Possible antigens under evaluation include oxidised LDL and its subparticles, heat-shock proteins and cholesteryl ester transfer protein. With cardiovascular disease being the single leading cause of death worldwide, the development of a safe and successful antiatherosclerosis

  20. Pre- and post-operative evaluations of eight dogs following right nephrectomy due to Dioctophyma renale.

    Science.gov (United States)

    Mesquita, L R; Rahal, S C; Faria, L G; Takahira, R K; Rocha, N S; Mamprim, M J; Oliveira, H S

    2014-01-01

    Dioctophyma renale is a large nematode distributed worldwide that may cause progressive and severe destruction of renal parenchyma. The present study aimed to evaluate pre- and post-operatively dogs submitted to right nephrectomy due to D. renale and to assess the histopathological damage of the removed kidney. Eight crossbred dogs, aged from 12 to 48 months that were unilaterally nephrectomized due to the presence of D. renale were evaluated. Physical examination, urinalysis, complete blood count, serum biochemistry, and abdominal ultrasound were performed immediately before and one month after nephrectomy. The nephrectomized right kidneys were submitted to macroscopic and microscopic evaluations. Urinalysis preoperatively detected occult blood in all dogs and D. renale eggs in five cases. Complete blood count showed all parameters within the reference range, except one dog post-operatively. Serum biochemistry performed before and after surgery verified that urea, creatinine and sodium were within the reference range values in all dogs. Other findings varied among the dogs. The length and arterial resistive index mean values of the left kidney were similar pre- and post-operatively. Thus, the inconsiderable change in laboratory findings pre- and post-operatively was attributable to compensation by left kidney function for the removed abnormal right kidney. Right kidney histology revealed chronic nephropathy due to D. renale. Imaging diagnosis should be performed on dogs suspected as carrying the disease or on those from an enzootic area since the laboratory findings are not specific except eggs in the urine.

  1. Effectiveness and Safety of Newer Antidiabetic Medications for Ramadan Fasting Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Ehab Mudher Mikhael

    2016-01-01

    Full Text Available Hypoglycemia is the most common side effects for most glucose-lowering therapies. It constitutes a serious risk that faces diabetic patients who fast during Ramadan (the 9th month in the Islamic calendar. New glucose-lowering classes like dipeptidyl peptidase-4 (DPP-4 inhibitors, glucagon-like peptide 1 receptor agonist (GLP-1 RA, and sodium-glucose cotransporter-2 (SGLT-2 inhibitors are efficacious in controlling blood glucose level with less tendency to induce hypoglycemia and thus may constitute a good choice for diabetic patients during Ramadan. This study reviews the safety and efficacy of newer glucose-lowering therapies during Ramadan. This study was accomplished through a careful literature search about studies that assess the benefit and side effects of these new glucose-lowering therapies during Ramadan during September 2015. Vildagliptin, sitagliptin, liraglutide, exenatide, and dapagliflozin were the only studied glucose-lowering therapies. All of the studied newer glucose-lowering therapies except dapagliflozin were associated with reduced risk to induce hypoglycemia. Gastrointestinal upset was common with the usage of liraglutide while increased thirst sensation was common with dapagliflozin. In conclusion DPP-4 inhibitors such as vildagliptin and sitagliptin may form a suitable glucose-lowering therapy option for Ramadan fasting patients.

  2. Renal artery stenosis and hypertension after abdominal irradiation for Hodgkin disease. Successful treatment with nephrectomy

    International Nuclear Information System (INIS)

    Salvi, S.; Green, D.M.; Brecher, M.L.; Magoos, I.; Gamboa, L.N.; Fisher, J.E.; Baliah, T.; Afshani, E.

    1983-01-01

    Hypertension secondary to stenosis of the left renal artery developed in a thirteen-year-old male six years after completion of inverted Y irradiation (3,600 rad) for abdominal Hodgkin disease. Surgical treatment with nephrectomy resulted in control of the hypertension without the use of antihypertensive agents. We review the literature for this unusual complication of abdominal irradiation, and recommend that a 99mTc-DMSA renal scan, selective renal vein sampling for renin determinations, and renal arteriography be performed on any patient in whom hypertension develops following abdominal irradiation in childhood

  3. Improved measurement of the glomerular filtration rate from Tc-99m DTPA scintigraphy in patients following nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong-il; Ha, Seunggyun [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Seoul National University Bundang Hospital, Department of Nuclear Medicine, Seongnam-si, Gyeonggi-do (Korea, Republic of); So, Young [Konkuk University School of Medicine, Department of Nuclear Medicine, Chungju (Korea, Republic of); Lee, Won Woo [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Seoul National University, Institute of Radiation Medicine, Medical Research Center, Seoul (Korea, Republic of); Seoul National University Bundang Hospital, Department of Nuclear Medicine, Seongnam-si, Gyeonggi-do (Korea, Republic of); Byun, Seok-Soo [Seoul National University College of Medicine, Department of Urology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Kim, Sang Eun [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Seoul National University, Institute of Radiation Medicine, Medical Research Center, Seoul (Korea, Republic of)

    2014-02-15

    We aimed to improve Tc-99m DTPA glomerular filtration rate (GFR) scintigraphy (Gates' method) in a prospective study using Cr-51 EDTA GFR test as a gold standard. Fifty-seven Tc-99m DTPA GFR scintigrams in 45 subjects (male/female = 33:12, age = 45.9 ± 17.6 years, 14 healthy volunteers and 31 nephrectomised patients) were compared using Cr-51 EDTA GFR tests. Using the %renal uptake of Tc-99m DTPA and Cr-51 EDTA GFR, a revised equation for GFR was established through linear regression analysis. The revised equation for improved GFR was GFR(mL/min) = (%renal uptake x 11.7773) - 0.7354. Gates' original GFRs (70.1 ± 20.5 mL/min/1.73 m{sup 2}) were significantly lower than Cr-51 EDTA GFRs (97.0 ± 31.9 mL/min/1.73 m{sup 2}; P < 0.0001), but the improved GFRs (98.0 ± 26.3 mL/min/1.73 m{sup 2}) were not different from (P = 0.7360) and had a significant correlation with (r = 0.73, P < 0.0001) the Cr-51 EDTA GFRs. The revised GFR equation effectively demonstrated perioperative GFR changes in kidneys that were operated on and the contralateral kidneys at 3 and 6 months post-partial nephrectomy (n = 25). GFR measurement using Tc-99m DTPA scintigraphy could be significantly improved by a revised equation derived from the comparison with Cr-51 EDTA GFR. (orig.)

  4. Crash-related mortality and model year: are newer vehicles safer?

    Science.gov (United States)

    Ryb, Gabriel E; Dischinger, Patricia C; McGwin, Gerald; Griffin, Russell L

    2011-01-01

    The objective of this study was to determine whether occupants of newer vehicles experience a lower risk of crash-related mortality. The occurrence of death was studied in relation to vehicle model year (MY) among front seat vehicular occupants, age ≥ 16 captured in the National Automotive Sampling System Crashworthiness Data System (NASS-CDS) between 2000 and 2008. The associations between death and other occupant, vehicular and crash characteristics were also explored. Multiple logistic regression models for the prediction of death were built with model year as the independent variable and other characteristics linked to death as covariates. Imputation was used for missing data; weighted data was used. A total of 70,314 cases representing 30,514,372 weighted cases were available for analysis. Death occurred in 0.6% of the weighted population. Death was linked to age>60, male gender, higher BMI, near lateral direction of impact, high delta v, rollover, ejection and vehicle mismatch, and negatively associated with seatbelt use and rear and far lateral direction of impact. Mortality decreased with later model year groups (MY<94 0.78%, MY 94-97 0.53%, MY 98-04 0.51% and MY 05-08 0.38%, p=<0.0001). After adjustment for confounders, MY 94-97, MY 98-04 and MY 05-08 showed decreased odds of death [OR 0.80 (0.69-0.94), 0.82 (0.70-0.97), and 0.67 (0.47-0.96), respectively] when compared to MY <94. Newer vehicles are associated with lower crash-related mortality. Their introduction into the vehicle fleet may explain, at least in part, the decrease in mortality rates in the past two decades.

  5. End Stage and Chronic Kidney Disease:Associations with Renal Cancer

    Directory of Open Access Journals (Sweden)

    Paul eRusso

    2012-04-01

    Full Text Available There is a well known association between end stage renal disease and the development of kidney cancer in the native kidney of patients requiring renal replacement therapy. There is now emerging evidence that lesser degrees of renal insufficiency (chronic kidney disease, CKD are also associated with an increased likelihood of cancer in general and kidney cancer in particular. Nephro pathological changes are commonly observed in the non tumor bearing portions of kidney resected at the time of partial and radical nephrectomy. In addition, patients with renal cancer are more likely to have CKD at the time of diagnosis and treatment than the general population. The exact mechanism by which renal insufficiency transforms normal kidney cells into tumor cells is not known. Possible mechanisms include uremic immune inhibition or increased exposure to circulating toxins not adequately cleared by the kidneys. Surgeons managing kidney tumors must have an increased awareness of their patient’s renal functional status as they plan their resection. Kidney sparing approaches, including partial nephrectomy or active surveillance in older and morbidly ill patients, can prevent CKD or delay the further decline in renal function which is well documented with radical nephrectomy. Despite emerging evidence that partial nephrectomy provides equivalent local tumor control to radical nephrectomy while at the same time preventing CKD, this operation remains under utilized in the United States and abroad. Increased awareness of the bi directional relationship between kidney function and kidney cancer is essential in the contemporary management of kidney cancer.

  6. Laparoscopic resection of tumor recurrence after radical nephrectomy for localized renal cell carcinoma

    Directory of Open Access Journals (Sweden)

    Lessandro Curcio

    2014-06-01

    Full Text Available Introduction Local recurrence of Renal Cell Carcinoma (RCC after radical nephrectomy is a rare event. Some known risk factors are: clinical/pathological stage, locorregional disease and lyimph node positivity. Since up to 30-40% of patients can achieve a disease-free status, we show a case (video in which we performed a laparoscopic excision of a local RCC, taking advantage of all the well-known benefits of laparoscopy.Case report A 56 years old female with a history of open radical nephrectomy two years before was diagnosed with a mass at the time of surveillance CT imaging during follow-up. The suspected local recurrence was 12cm, and vascularized predominantly by tributaries originating from the iliac vessels. There was no other site of disease (i.e. brain, lung, liver, bones and laboratory tests were normal. Laparoscopic approach was approached, by inserting 4 trocars (2 of 10 and 2 of 5mm with the patient in the lateral position.Result The procedure lasted 130 minutes, with 220mL of estimated bleeding; the larger vessels were ligated with polymer clips (Hem-o-lok and the smaller handled by ultrasonic clamp. The specimen was removed by a small incision below the umbilicus in an appropriate bag. The patient was feed in the first postoperative day and discharged on the third day. Histopathology revealed sarcoma, with a high degree of mitosis, and negative surgical margins. She was referred to medical oncology for adjuvant therapy consideration.Conclusion The laparoscopic resection of recurrent tumor should be encouraged in highly selected cases. The minimally invasive method, with its known advantages, especially for more debilitated patients, can be advantageous when applied to suitable cases.

  7. Adjuvant Sunitinib for High-risk Renal Cell Carcinoma After Nephrectomy: Subgroup Analyses and Updated Overall Survival Results.

    Science.gov (United States)

    Motzer, Robert J; Ravaud, Alain; Patard, Jean-Jacques; Pandha, Hardev S; George, Daniel J; Patel, Anup; Chang, Yen-Hwa; Escudier, Bernard; Donskov, Frede; Magheli, Ahmed; Carteni, Giacomo; Laguerre, Brigitte; Tomczak, Piotr; Breza, Jan; Gerletti, Paola; Lechuga, Mariajose; Lin, Xun; Casey, Michelle; Serfass, Lucile; Pantuck, Allan J; Staehler, Michael

    2018-01-01

    Adjuvant sunitinib significantly improved disease-free survival (DFS) versus placebo in patients with locoregional renal cell carcinoma (RCC) at high risk of recurrence after nephrectomy (hazard ratio [HR] 0.76, 95% confidence interval [CI] 0.59-0.98; p=0.03). To report the relationship between baseline factors and DFS, pattern of recurrence, and updated overall survival (OS). Data for 615 patients randomized to sunitinib (n=309) or placebo (n=306) in the S-TRAC trial. Subgroup DFS analyses by baseline risk factors were conducted using a Cox proportional hazards model. Baseline risk factors included: modified University of California Los Angeles integrated staging system criteria, age, gender, Eastern Cooperative Oncology Group performance status (ECOG PS), weight, neutrophil-to-lymphocyte ratio (NLR), and Fuhrman grade. Of 615 patients, 97 and 122 in the sunitinib and placebo arms developed metastatic disease, with the most common sites of distant recurrence being lung (40 and 49), lymph node (21 and 26), and liver (11 and 14), respectively. A benefit of adjuvant sunitinib over placebo was observed across subgroups, including: higher risk (T3, no or undetermined nodal involvement, Fuhrman grade ≥2, ECOG PS ≥1, T4 and/or nodal involvement; hazard ratio [HR] 0.74, 95% confidence interval [CI] 0.55-0.99; p=0.04), NLR ≤3 (HR 0.72, 95% CI 0.54-0.95; p=0.02), and Fuhrman grade 3/4 (HR 0.73, 95% CI 0.55-0.98; p=0.04). All subgroup analyses were exploratory, and no adjustments for multiplicity were made. Median OS was not reached in either arm (HR 0.92, 95% CI 0.66-1.28; p=0.6); 67 and 74 patients died in the sunitinib and placebo arms, respectively. A benefit of adjuvant sunitinib over placebo was observed across subgroups. The results are consistent with the primary analysis, which showed a benefit for adjuvant sunitinib in patients at high risk of recurrent RCC after nephrectomy. Most subgroups of patients at high risk of recurrent renal cell carcinoma after

  8. Newer trace elements measured by RNNA and AAS

    International Nuclear Information System (INIS)

    Gharib, A.G.

    2004-01-01

    Very recently, special attention has been made on a few more trace elements in foodstuff as newer essential for animal and human health in certain ranges of concentration or intakes. These traces are namely: Aluminium, Nickel, Vanadium and Tin. A1 and Ni have been measured by Atomic Absorption Spectroscopy and two latter ones measured by Radiochemical Neutron Activation Analysis in some references laboratories. Here also scandium was analyzed by Instrumental Neutron Activation Analysis as well. These measurements were made for the most of Iranian diets and other participant countries' diets in frame of coordinated research project led by International Atomic Energy Agency period of 1986-1994, but practically it took more years. Here in this work the daily dietary intakes of aforesaid trace elements are given and discussed while the results of other 20 more nutritionally important trace elements were appeared somewhere else

  9. MDCT evaluation of potential living renal donor, prior to laparoscopic donor nephrectomy: What the transplant surgeon wants to know?

    Directory of Open Access Journals (Sweden)

    Nitin P Ghonge

    2014-01-01

    Full Text Available As Laparoscopic Donor Nephrectomy (LDN offers several advantages for the donor such as lesser post-operative pain, fewer cosmetic concerns and faster recovery time, there is growing global trend towards LDN as compared to open nephrectomy. Comprehensive pre-LDN donor evaluation includes assessment of renal morphology including pelvi-calyceal and vascular system. Apart from donor selection, evaluation of the regional anatomy allows precise surgical planning. Due to limited visualization during laparoscopic renal harvesting, detailed pre-transplant evaluation of regional anatomy, including the renal venous anatomy is of utmost importance. MDCT is the modality of choice for pre-LDN evaluation of potential renal donors. Apart from appropriate scan protocol and post-processing methods, detailed understanding of surgical techniques is essential for the Radiologist for accurate image interpretation during pre-LDN MDCT evaluation of potential renal donors. This review article describes MDCT evaluation of potential living renal donor, prior to LDN with emphasis on scan protocol, post-processing methods and image interpretation. The article laid special emphasis on surgical perspectives of pre-LDN MDCT evaluation and addresses important points which transplant surgeons want to know.

  10. Simultaneous nephrectomy and coronary artery bypass grafting through extended sternotomy

    Directory of Open Access Journals (Sweden)

    Budrikis Algimantas

    2012-08-01

    Full Text Available Abstract Background The advances in surgical techniques, resuscitation and anesthesiology support over the last years have allowed simultaneous thoracic and abdominal operations to be made for cancer and concomitant severe heart vessel disease relieving the patient from several diseases simultaneously and achieving long lasting remission or cure. Clinical case A simultaneous nephrectomy and coronary artery bypass grafting procedure through extended sternotomy is reported. A 63-year-old man with severe coronary artery disease was found to have renal carcinoma. Diagnosis Postoperative pathological investigation of the tumor revealed the presence of renal cell carcinoma pT3a N0 M0, G2. Coronarography revealed advanced three-vessel coronary artery disease. Treatment We successfully performed a simultaneous curative surgery for renal carcinoma and coronary artery bypass graft surgery under cardiopulmonary bypass using a novel technique of extended sternotomy. Simultaneous surgery thus appears to be a beneficial and safe approach for the treatment of coronary artery disease and resectable renal cancer in carefully selected patients.

  11. Newer insights in teledermatology practice

    Directory of Open Access Journals (Sweden)

    Garehatty Rudrappa Kanthraj

    2011-01-01

    Full Text Available The study and practice of dermatology care using interactive audio, visual, and data communications from a distance is called teledermatology. A teledermatology practice (TP provides teleconsultation as well tele-education. Initially, dermatologists used videoconference. Convenience, cost-effectiveness and easy application of the practice made "store and forward" to emerge as a basic teledermatology tool. The advent of newer technologies like third generation (3G and fourth generation (4G mobile teledermatology (MT and dermatologists′ interest to adopt tertiary TP to pool expert (second opinion to address difficult-to-manage cases (DMCs has resulted in a rapid change in TP. Online discussion groups (ODGs, author-based second opinion teledermatology (AST, or a combination of both are the types of tertiary TP. This article analyzes the feasibility studies and provides latest insight into TP with a revised classification to plan and allocate budget and apply appropriate technology. Using the acronym CAP-HAT, which represents five important factors like case, approach, purpose, health care professionals, and technology, one can frame a TP. Store-and-forward teledermatology (SAFT is used to address routine cases (spotters. Chronic cases need frequent follow-up care. Leg ulcer and localized vitiligo need MT while psoriasis and leprosy require SAFT. Pigmented skin lesions require MT for triage and combination of teledermoscopy, telepathology, and teledermatology for diagnosis. A self-practising dermatologist and national health care system dermatologist use SAFT for routine cases and a combination of ASTwith an ODG to address a DMC. A TP alone or in combination with face-to-face consultation delivers quality care.

  12. Do the different types of renal surgery impact the quality of life in the postoperative period?

    DEFF Research Database (Denmark)

    Azawi, Nessn H.; Tesfalem, H; Dahl, C

    2015-01-01

    was associated with a significant decrease in emotional functioning and role functioning compared with never thinking about one's cancer. CONCLUSION: Total nephrectomy was a negative predictor of overall global health status. There is a demand for a reasonable follow-up program with an individual control......PURPOSE: Because more than 70 % of patients with localized tumors experience 10 years of cancer-specific survival, their quality of life (QoL) after surgery is important. The aim of this study was to explore the impact of the type of surgery (partial vs. total nephrectomy) and the postoperative...... outcome on the QoL of patients with renal cancer. METHODS: A total of 205 patients underwent partial or total nephrectomy at the Department of Urology, Roskilde Hospital, between February 2008 and June 2013 and survived until the time of the survey. The European Organization for Research and Treatment...

  13. Randomized clinical trial of transversus abdominis plane block versus placebo control in live-donor nephrectomy.

    Science.gov (United States)

    Hosgood, Sarah A; Thiyagarajan, Umasanker M; Nicholson, Harriet F L; Jeyapalan, Inthira; Nicholson, Michael L

    2012-09-15

    Laparoscopic surgery reduces pain after donor nephrectomy; however, most patients still require a significant amount of postoperative parenteral opiate analgesia. Therefore, there is a need to investigate techniques that might further reduce postoperative pain. This study assessed the safety and efficacy of using a transversus abdominis plane (TAP) block in a randomized, double-blind, placebo-controlled trial. Forty-six patients were analyzed in the trial and were randomized to undergo the TAP block procedure with either bupivacaine (n=24) or saline placebo (Control n=22) injected into the muscle plane. Prefilled syringes were dispensed with the group allocation concealed to maintain blinding. After surgery, the amount of morphine, level of pain, and measures of recovery were recorded. The amount of morphine used 6 hr after surgery was significantly lower in patients receiving TAP block with bupivacaine compared with the control (presented as mean [SD], 12.4 [8.4] vs. 21.2 [14.0] mg; P=0.015). However, the total amount of morphine used was similar in both groups 45.6 [31.4] vs. 52.7 [28.8] mg; P=0.771. Patients in the bupivacaine group experienced significantly less pain on postoperative days 1 (score, 19 [15] vs. 37 [20]; P=0.003) and 2 (score, 11 [10] vs. 19 [13]; P=0.031). Recovery and postoperative hospital stay were similar in both groups. There were no complications associated with the procedure. The TAP block procedure is beneficial in reducing postoperative pain and early morphine requirements in laparoscopic live-donor nephrectomy.

  14. Ozone Therapy on Rats Submitted to Subtotal Nephrectomy: Role of Antioxidant System

    Directory of Open Access Journals (Sweden)

    José Luis Calunga

    2005-01-01

    Full Text Available Chronic renal failure (CRF represents a world health problem. Ozone increases the endogenous antioxidant defense system, preserving the cell redox state. The aim of this study is to evaluate the effect of ozone/oxygen mixture in the renal function, morphology, and biochemical parameters, in an experimental model of CRF (subtotal nephrectomy. Ozone/oxygen mixture was applied daily, by rectal insufflation (0.5 mg/kg for 15 sessions after the nephrectomy. Renal function was evaluated, as well as different biochemical parameters, at the beginning and at the end of the study (10 weeks. Renal plasmatic flow (RPF, glomerular filtration rate (GFR, the urine excretion index, and the sodium and potassium excretions (as a measurement of tubular function in the ozone group were similar to those in Sham group. Nevertheless, nephrectomized rats without ozone (positive control group showed the lowest RPF, GFR, and urine excretion figures, as well as tubular function. Animals treated with ozone showed systolic arterial pressure (SAP figures lower than those in the positive control group, but higher values compared to Sham group. Serum creatinine values and protein excretion in 24 hours in the ozone group were decreased compared with nephrectomized rats, but were still higher than normal values. Histological study demonstrated that animals treated with ozone showed less number of lesions in comparison with nephrectomized rats. Thiobarbituric acid reactive substances were significantly increased in nephrectomized and ozone-treated nephrectomized rats in comparison with Sham group. In the positive control group, superoxide dismutase (SOD and catalase (CAT showed the lowest figures in comparison with the other groups. However, ozone/oxygen mixture induced a significant stimulation in the enzymatic activity of CAT, SOD, and glutathione peroxidase, as well as reduced glutathione in relation with Sham and positive control groups. In this animal model of CRF, ozone

  15. Changes in glomerular filtration rate, lithium clearance and plasma protein clearances in the early phase after unilateral nephrectomy in living healthy renal transplant donors

    DEFF Research Database (Denmark)

    Strandgaard, S; Kamper, A; Skaarup, P

    1988-01-01

    1. Glomerular and tubular function was studied before and 2 months after unilateral nephrectomy in 14 healthy kidney donors by measurement of the clearances of 51Cr-labelled ethylenediaminetetra-acetate, lithium, beta 2-microglobulin, albumin and immunoglobulin G. 2. The glomerular filtration rat...

  16. Two-Year Clinical Outcomes of Newer-Generation Drug-Eluting Stent Implantation Following Rotational Atherectomy for Heavily Calcified Lesions.

    Science.gov (United States)

    Jinnouchi, Hiroyuki; Kuramitsu, Shoichi; Shinozaki, Tomohiro; Kobayashi, Yohei; Hiromasa, Takashi; Morinaga, Takashi; Mazaki, Toru; Sakakura, Kenichi; Soga, Yoshimitsu; Hyodo, Makoto; Shirai, Shinichi; Ando, Kenji

    2015-01-01

    Clinical outcomes of implantation of the newer-generation drug-eluting stent (DES) following rotational atherectomy for heavily calcified lesions remain unclear in the real-world setting. We enrolled 252 consecutive patients (273 lesions) treated with newer-generation DES following rotational atherectomy. The primary endpoint was the cumulative 2-year incidence of major adverse cardiovascular events (MACE), defined as cardiac death, myocardial infarction, clinically-driven target lesion revascularization, and definite stent thrombosis. Complete clinical follow-up information at 2-year was obtained for all patients. The mean age was 73.2±9.0 years and 155 patients (61.5%) were male. Cumulative 2-year incidence of MACE (cardiac death, myocardial infarction, clinically-driven target lesion revascularization and definite stent thrombosis) was 20.3% (7.0%, 2.1%, 18.1% and 2.1%, respectively). Predictors of MACE were presenting with acute coronary syndrome (hazard ratio [HR]: 3.80, 95% confidence interval [CI]: 1.29-11.2, P=0.02), hemodialysis (HR: 1.93, 95% CI: 1.04-3.56, P=0.04) and previous coronary artery bypass graft (HR: 2.26, 95% CI: 1.02-5.00, P=0.045). PCI for calcified lesions requiring rotational atherectomy is still challenging even in the era of newer-generation DES.

  17. Urology residents experience comparable workload profiles when performing live porcine nephrectomies and robotic surgery virtual reality training modules.

    Science.gov (United States)

    Mouraviev, Vladimir; Klein, Martina; Schommer, Eric; Thiel, David D; Samavedi, Srinivas; Kumar, Anup; Leveillee, Raymond J; Thomas, Raju; Pow-Sang, Julio M; Su, Li-Ming; Mui, Engy; Smith, Roger; Patel, Vipul

    2016-03-01

    In pursuit of improving the quality of residents' education, the Southeastern Section of the American Urological Association (SES AUA) hosts an annual robotic training course for its residents. The workshop involves performing a robotic live porcine nephrectomy as well as virtual reality robotic training modules. The aim of this study was to evaluate workload levels of urology residents when performing a live porcine nephrectomy and the virtual reality robotic surgery training modules employed during this workshop. Twenty-one residents from 14 SES AUA programs participated in 2015. On the first-day residents were taught with didactic lectures by faculty. On the second day, trainees were divided into two groups. Half were asked to perform training modules of the Mimic da Vinci-Trainer (MdVT, Mimic Technologies, Inc., Seattle, WA, USA) for 4 h, while the other half performed nephrectomy procedures on a live porcine model using the da Vinci Si robot (Intuitive Surgical Inc., Sunnyvale, CA, USA). After the first 4 h the groups changed places for another 4-h session. All trainees were asked to complete the NASA-TLX 1-page questionnaire following both the MdVT simulation and live animal model sessions. A significant interface and TLX interaction was observed. The interface by TLX interaction was further analyzed to determine whether the scores of each of the six TLX scales varied across the two interfaces. The means of the TLX scores observed at the two interfaces were similar. The only significant difference was observed for frustration, which was significantly higher at the simulation than the animal model, t (20) = 4.12, p = 0.001. This could be due to trainees' familiarity with live anatomical structures over skill set simulations which remain a real challenge to novice surgeons. Another reason might be that the simulator provides performance metrics for specific performance traits as well as composite scores for entire exercises. Novice trainees experienced

  18. Treatment options for renal cell carcinoma in renal allografts: a case series from a single institution.

    Science.gov (United States)

    Swords, Darden C; Al-Geizawi, Samer M; Farney, Alan C; Rogers, Jeffrey; Burkart, John M; Assimos, Dean G; Stratta, Robert J

    2013-01-01

    Renal cell carcinoma (RCC) is more common in renal transplant and dialysis patients than the general population. However, RCC in transplanted kidneys is rare, and treatment has previously consisted of nephrectomy with a return to dialysis. There has been recent interest in nephron-sparing procedures as a treatment option for RCC in allograft kidneys in an effort to retain allograft function. Four patients with RCC in allograft kidneys were treated with nephrectomy, partial nephrectomy, or radiofrequency ablation. All of the patients are without evidence of recurrence of RCC after treatment. We found nephron-sparing procedures to be reasonable initial options in managing incidental RCCs diagnosed in functioning allografts to maintain an improved quality of life and avoid immediate dialysis compared with radical nephrectomy of a functioning allograft. However, in non-functioning renal allografts, radical nephrectomy may allow for a higher chance of cure without the loss of transplant function. Consequently, radical nephrectomy should be utilized whenever the allograft is non-functioning and the patient's surgical risk is not prohibitive. © 2013 John Wiley & Sons A/S.

  19. Current Controversies in Newer Therapies to Treat Birth Asphyxia

    Directory of Open Access Journals (Sweden)

    Pia Wintermark

    2011-01-01

    Full Text Available Despite major advances in monitoring technology and knowledge of fetal and neonatal pathophysiology, neonatal hypoxic-ischemic encephalopathy (HIE remains one of the main causes of severe adverse neurological outcome in children. Until recently, there were no therapies other than supportive measures. Over the past several years, mild hypothermia has been proven to be safe to treat HIE. Unfortunately, this neuroprotective strategy seems efficient in preventing brain injury in some asphyxiated newborns, but not in all of them. Thus, there is increasing interest to rapidly understand how to refine hypothermia therapy and add neuroprotective or neurorestorative strategies. Several promising newer treatments to treat birth asphyxia and prevent its devastating neurological consequences are currently being tested. In this paper, the physiopathology behind HIE, the currently available treatment, the potential alternatives, and the next steps before implementation of these other treatments are reviewed.

  20. Older and Newer Media: Patterns of Use and Effects on Adolescents' Health and Well-Being

    Science.gov (United States)

    Brown, Jane D.; Bobkowski, Piotr S.

    2011-01-01

    The past decade's research on the use and effects of older (television, music, movies, magazines) and newer media (the Internet, cell phones, social networking) on adolescents' health and well-being is reviewed. A portrait of patterns of use of the media is provided and then the predictors and effects of those patterns on adolescents' mental…

  1. Medline Plus

    Full Text Available ... Mission Medical Center, Merriam, KS, 05/04/2012) Kidney Cancer Robot Assisted Partial Nephrectomy Using Fluorescence (Shawnee ... Medical Center, Winston-Salem, NC, 09/17/2015) Kidneys and Urinary System Kidney Cancer Robot Assisted Partial ...

  2. Effect of Regional Hospital Competition and Hospital Financial Status on the Use of Robotic-Assisted Surgery.

    Science.gov (United States)

    Wright, Jason D; Tergas, Ana I; Hou, June Y; Burke, William M; Chen, Ling; Hu, Jim C; Neugut, Alfred I; Ananth, Cande V; Hershman, Dawn L

    2016-07-01

    Despite the lack of efficacy data, robotic-assisted surgery has diffused rapidly into practice. Marketing to physicians, hospitals, and patients has been widespread, but how this marketing has contributed to the diffusion of the technology remains unknown. To examine the effect of regional hospital competition and hospital financial status on the use of robotic-assisted surgery for 5 commonly performed procedures. A cohort study of 221 637 patients who underwent radical prostatectomy, total nephrectomy, partial nephrectomy, hysterectomy, or oophorectomy at 1370 hospitals in the United States from January 1, 2010, to December 31, 2011, was conducted. The association between hospital competition, hospital financial status, and performance of robotic-assisted surgery was examined. The association between hospital competition was measured with the Herfindahl-Hirschman Index (HHI), hospital financial status was estimated as operating margin, and performance of robotic-assisted surgery was examined using multivariate mixed-effects regression models. We identified 221 637 patients who underwent one of the procedures of interest. The cohort included 30 345 patients who underwent radical prostatectomy; 20 802, total nephrectomy; 8060, partial nephrectomy; 134 985, hysterectomy; and 27 445, oophorectomy. Robotic-assisted operations were performed for 20 500 (67.6%) radical prostatectomies, 1405 (6.8%) total nephrectomies, 2759 (34.2%) partial nephrectomies, 14 047 (10.4%) hysterectomies, and 1782 (6.5%) oophorectomies. Use of robotic-assisted surgery increased for each procedure from January 2010 through December 2011. For all 5 operations, increased market competition (as measured by the HHI) was associated with increased use of robotic-assisted surgery. For prostatectomy, the risk ratios (95% CIs) for undergoing a robotic-assisted procedure were 2.20 (1.50-3.24) at hospitals in moderately competitive markets and 2.64 (1.84-3.78) for highly competitive markets

  3. Current Status of Nephron-Sparing Surgery (NSS) in the Management of Renal Tumours.

    Science.gov (United States)

    Venkatramani, Vivek; Swain, Sanjaya; Satyanarayana, Ramgopal; Parekh, Dipen J

    2017-06-01

    Nephron-sparing surgery has emerged as the surgical treatment of choice for small renal masses over the past two decades, replacing the traditional teaching of radical nephrectomy for renal cell carcinoma. With time, there has been an evolution in the techniques and indications for partial nephrectomy. This review summarizes the current status of nephron-sparing surgery for renal carcinoma and also deals with the future of this procedure.

  4. Morphometric scores for renal tumors: What does the radiologist need to know?

    Energy Technology Data Exchange (ETDEWEB)

    Millet, Ingrid; Doyon, Fernanda Curros; Pages, Emma [Department of Imaging, CHU Montpellier (France); Thuret, Rodolphe [Department of Urology, CHU Montpellier (France); Taourel, Patrice, E-mail: p-taourel@chu-montpellier.fr [Department of Imaging, CHU Montpellier (France)

    2014-08-15

    Numerous therapeutic options are possible in the treatment of renal carcinomas including radical nephrectomy, partial nephrectomy, cryoablation, radiofrequency, active follow-up and among surgical treatments, different approaches may be used such as laparotomy, laparoscopy, robotic-assisted intervention. The choice between these different procedures is partially based on the anatomic conditions of the tumors. Different anatomic scores determined from cross-sectional imaging have been built to predict the complexity of the surgical procedure. The goals of this article are to review the relevant morphologic pattern for management of patients with renal tumors, to know how to calculate these different scores and to understand the clinical applications of these scores.

  5. Morphometric scores for renal tumors: What does the radiologist need to know?

    International Nuclear Information System (INIS)

    Millet, Ingrid; Doyon, Fernanda Curros; Pages, Emma; Thuret, Rodolphe; Taourel, Patrice

    2014-01-01

    Numerous therapeutic options are possible in the treatment of renal carcinomas including radical nephrectomy, partial nephrectomy, cryoablation, radiofrequency, active follow-up and among surgical treatments, different approaches may be used such as laparotomy, laparoscopy, robotic-assisted intervention. The choice between these different procedures is partially based on the anatomic conditions of the tumors. Different anatomic scores determined from cross-sectional imaging have been built to predict the complexity of the surgical procedure. The goals of this article are to review the relevant morphologic pattern for management of patients with renal tumors, to know how to calculate these different scores and to understand the clinical applications of these scores

  6. The newer aspect of dexmedetomidine use in dentistry: As an additive to local anesthesia, initial experience, and review of literature.

    Science.gov (United States)

    Kumar, Prashant; Thepra, Manju; Bhagol, Amrish; Priya, Kannu; Singh, Virendra

    2016-01-01

    Despite the availability of a wide variety of pharmacological agents in the field of anesthesia, there has always been a continuous search for newer local anesthetic agents with improved efficacy, potency, and better handling properties. Dexmedetomidine, a selective alpha-2 adrenergic receptor agonist, is an emerging agent for provision of additive local anesthetic effect if used with conventional local anesthetics, which can be implicated in dentistry for performing many minor oral surgical procedures. The present paper reports a pilot study comparing clinical efficacy and potency of this newer emerging drug in combination with lignocaine. Ten patients undergoing orthodontic extraction for correction of malocclusion and other dentofacial deformities requiring orthodontic treatment were locally infiltrated with 2% lignocaine plus dexmedetomidine 1μ/ml and 2% lignocaine plus adrenaline in 1:200,000 dilution at two different appointments. The onset of action, duration of action, and pain threshold were assessed. Onset of action was found to be faster with longer duration of action with the newer drug dexmedetomidine and lignocaine combination when compared with combination of lignocaine and adrenaline. The study demonstrated that the combination of dexmedetomidine with lignocaine enhances the local anesthetic potency of lignocaine without significant systemic effects when locally injected into oral mucosa.

  7. [Post-operative pain after ultrasound transversus abdominis plane block versus trocar site infiltration in laparoscopic nephrectomy: a prospective study].

    Science.gov (United States)

    Araújo, Ana M; Guimarães, Joana; Nunes, Catarina S; Couto, Paula S; Amadeu, Eduarda

    Transversus abdominis plane (TAP) block is useful in reducing post-operative pain in laparoscopic nephrectomy compared to placebo. The purpose of this work is to compare post-operative pain and recovery after TAP block or trocar site infiltration (TSI) in this surgery. A prospective, single blinded study on patients scheduled for laparoscopic nephrectomy. Patients were assigned to two groups: TSI Group: trocar site infiltration at the end of surgery; TAP Group: unilateral ultrasound-guided TAP block after induction. Sevoflurane and remifentanil, in a target controlled infusion mode, were used for maintenance of general anesthesia. Before the end of surgery paracetamol, tramadol and morphine were administered. Visual analogue scale (VAS 0-100mm) at rest and with cough was applied in three moments: in recovery room (T1 at admission and T2 before discharge) and 24h after surgery (T3). Pain scores with incentive spirometer were also evaluated at T3. In recovery, morphine was administered as a rescue drug whenever VAS>30mm. Time to oral intake, chair sitting, ambulation and length of hospital stay were evaluated 24h after surgery. Student's t-test and Chi-square test, and linear regression models. A p-value0.05). VAS at rest (TAP vs. TSI groups) was: T1=33±29 vs. 39±32, T2=10±9 vs. 17±18 and T3=7±12 vs. 10±18. VAS with cough (TAP vs. TSI groups) was: T1=51±34 vs. 45±32, T2=24±24 vs. 33±23 and T3=20±23 vs. 23±23. VAS with incentive spirometer (TAP vs. TSI groups) was: T3=21±27 vs. 21±25. Intraoperative remifentanil consumption was similar between TAP (0.16±0.07mcg.kg -1 .min -1 ) and TSI (0.18±0.9mcg.kg -1 .min -1 ) groups. There were no differences in opioid consumption between TAP (4.4±3.49mg) and TSI (6.87±4.83mg) groups during recovery. Functional recovery parameters were not statistically different between groups. Multimodal analgesia with TAP block did not show a significant clinical benefit compared with trocar site infiltration in laparoscopic

  8. Post-operative pain after ultrasound transversus abdominis plane block versus trocar site infiltration in laparoscopic nephrectomy: a prospective study

    Directory of Open Access Journals (Sweden)

    Ana M. Araújo

    Full Text Available Abstract Background Transversus abdominis plane (TAP block is useful in reducing post-operative pain in laparoscopic nephrectomy compared to placebo. The purpose of this work is to compare post-operative pain and recovery after TAP block or trocar site infiltration (TSI in this surgery. Methods A prospective, single blinded study on patients scheduled for laparoscopic nephrectomy. Patients were assigned to two groups: TSI Group: trocar site infiltration at the end of surgery; TAP Group: unilateral ultrasound-guided TAP block after induction. Sevoflurane and remifentanil, in a target controlled infusion mode, were used for maintenance of general anesthesia. Before the end of surgery paracetamol, tramadol and morphine were administered. Visual analogue scale (VAS 0-100 mm at rest and with cough was applied in three moments: in recovery room (T1 at admission and T2 before discharge and 24 h after surgery (T3. Pain scores with incentive spirometer were also evaluated at T3. In recovery, morphine was administered as a rescue drug whenever VAS > 30 mm. Time to oral intake, chair sitting, ambulation and length of hospital stay were evaluated 24 h after surgery. Statistical analysis: Student's t-test and Chi-square test, and linear regression models. A p-value 0.05. VAS at rest (TAP vs. TSI groups was: T1 = 33 ± 29 vs. 39 ± 32, T2 = 10 ± 9 vs. 17 ± 18 and T3 = 7 ± 12 vs. 10 ± 18. VAS with cough (TAP vs. TSI groups was: T1 = 51 ± 34 vs. 45 ± 32, T2 = 24 ± 24 vs. 33 ± 23 and T3 = 20 ± 23 vs. 23 ± 23. VAS with incentive spirometer (TAP vs. TSI groups was: T3 = 21 ± 27 vs. 21 ± 25. Intraoperative remifentanil consumption was similar between TAP (0.16 ± 0.07 mcg.kg-1.min-1 and TSI (0.18 ± 0.9 mcg.kg-1.min-1 groups. There were no differences in opioid consumption between TAP (4.4 ± 3.49 mg and TSI (6.87 ± 4.83 mg groups during recovery. Functional recovery parameters were not statistically different between groups. Conclusions Multimodal

  9. Renal Hemangiopericytoma

    Directory of Open Access Journals (Sweden)

    İbrahim Halil Bozkurt

    2015-03-01

    Full Text Available Hemangiopericytoma is an uncommon perivascular tumor originating from pericytes in the pelvis, head and tneck, and the meninges; extremely rarely in the urinary system. We report a case of incidentally detected renal mass in which radiologic evaluation was suggestive of renal cell carcinoma. First, we performed partial nephrectomy, and then, radical nephrectomy because of positive surgical margins and the pathological examination of the surgical specimen that revealed a hemangiopericytoma. No additional treatment was administered.

  10. Staged Hand-Assisted Bilateral Native Nephrectomy for Management of Posttransplant Polyuria in an Adult with Dent's Disease

    Science.gov (United States)

    Montero, Rosa M.; Olsburgh, Jonathon

    2015-01-01

    Polyuria after kidney transplantation causes graft dysfunction and increased thrombotic risk. We present a case of a polyuric adult with Dent's disease who underwent staged bilateral native nephrectomies, the first operation before transplant and the second four months after transplant. This led to improved allograft function maintained during four years of follow-up. The retroperitoneal laparoscopic approach was well tolerated and allowed continuation of peritoneal dialysis before transplantation. A staged approach helps regulate fluid balance perioperatively and may be tailored to individual need according to posttransplant urine output. This novel approach should be considered for polyuric patients with tubular dysfunction including Dent's disease. PMID:25649339

  11. Newer Demographic Development of the Settlement of Murter

    Directory of Open Access Journals (Sweden)

    Sonja Podgorelec

    1998-10-01

    Full Text Available Murter is the largest settlement on the same-named island and also in the entire Šibenik archipelago. As opposed to most of the settlements on the island, its population was less involved in earlier emigration flows, whereas newer emigration began to effect Murter only after the sixties. The effect of the depopulation period is visible in the changes of the age-sex structure, where can be seen primarily in ageing of the population and a disproportion in the sex ratio. Yet it can be confirmed that the settlement of Murter has not such an unfavourable demographic situation as do most Dalmatian islands. A slightly falling birth rate can be noticed, as well as a slight increase in the death rate. The demographic perspective of this population is relatively favourable (due to an expected development of tourism, development of agriculture and trades, nautical infrastructures etc., if addition emigration factors will not come into play. Based on a multiple-criteria evaluation of developmental levels, the island of Murter, primarily due to the central position of the settlement Murter, is ranked 11th out of 47 Croatian islands. The reason is that all higher ranked islands also have a significantly larger area.

  12. [Kidney function and renal cancer surgery].

    Science.gov (United States)

    Izzedine, Hassan; Méjean, Arnaud; Escudier, Bernard

    2014-02-01

    Although radical nephrectomy is still practiced in many patients with large renal tumors, oncology and nephrology arguments for kidney-sparing approach for small renal masses has taken over this first. Indeed, partial nephrectomy provides equivalent oncologic results while preserving renal function and thereby limit morbidity and cardiovascular mortality related to chronic kidney disease. In addition, patients who develop kidney cancer often have medical comorbidities that may affect renal function, such as diabetes and hypertension. Histological examination of renal tissue adjacent to the tumor showed significant pathological changes in the majority of patients. For elderly patients or patients with comorbidities, active surveillance allows kidney-sparing approach with extremely low rates of progression and metastasis of cancer disease. Despite these significant advances in understanding for the treatment of small renal masses, partial nephrectomy remains underused. Better management must take into account the preservation of renal function in order to increase overall survival. A strategy for the systematic evaluation of renal function in patients with CR, with multidisciplinary staff (nephrologist urologist and oncologist), is therefore highly desirable.

  13. Commentary on "Detailed analysis of morbidity following nephrectomy for renal cell carcinoma in octogenarians." Berger J, Fardoun T, Brassart E, Capon G, Bigot P, Bernhard JC, Rigaud J, Patard JJ, Descazeaud A, Department of Urology, Dupuytren University Hospital, Limoges, France: J Urol 2012;188(3):736-40 (Epub 2012 Jul 19).

    Science.gov (United States)

    Boorjian, Stephen

    2013-01-01

    We evaluated the morbidity of nephrectomy in patients older than 80 years of age. Between June 2002 and March 2011, 2,530 patients underwent surgery for renal tumor at 5 French academic centers. Of these patients, 180 (7.1%) were 80 years of age or older; 22 (12%) and 158 (88%) patients underwent partial and radical nephrectomy, respectively, and 47 (26.1%) of whom were treated with a laparoscopic approach. Mean patient age was 82.3 years. Median Charlson score was 4. Mean preoperative glomerular filtration rate was 47 ml/min. A total of 136 complications were recorded in 70 patients (38.8% of all patients). Of these patients, 28 (15.5%), 25 (13.9%), and 17 (9.4%) experienced 1, 2, and 3 or more complications, respectively. According to the modified Clavien classification grade I, II, III, IV, and V complications were observed in 7, 81, 19, 23, and 6 patients, respectively. The transfusion rate was 31.1% (56). On logistic regression analysis, the parameters of Eastern Cooperative Oncology Group Performance Status 2 to 4 (P = 0.035) and preoperative glomerular filtration rate less than 30 ml/min (P = 0.03) were independent predictive factors of morbidity. Morbidity and mortality are significant in the octogenarian population. The risk of complications should be considered in decision making for patients with renal cell carcinoma who were older than age 80 years. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Anti-GBM disease after nephrectomy for xanthogranulomatous pyelonephritis in a patient expressing HLA DR15 major histocompatibility antigens: a case report.

    Science.gov (United States)

    O'Hagan, Emma; Mallett, Tamara; Convery, Mairead; McKeever, Karl

    2015-01-01

    Antiglomerular basement membrane (anti-GBM) antibody disease is uncommon in the pediatric population. There are no cases in the literature describing the development of anti-GBM disease following XGP or nephrectomy. We report the case of a 7-year-old boy with no past history of urological illness, treated with antimicrobials and nephrectomy for diffuse, unilateral xanthogranulomatous pyelonephritis (XGP). Renal function and ultrasound scan of the contralateral kidney postoperatively were normal. Three months later, the child represented in acute renal failure with rapidly progressive glomerulonephritis requiring hemodialysis. Renal biopsy showed severe crescentic glomerulonephritis with 95% of glomeruli demonstrating circumferential cellular crescents. Strong linear IgG staining of the glomerular basement membranes was present, in keeping with anti-GBM disease. Circulating anti-GBM antibodies were positive. Treatment with plasma exchange, methylprednisolone, and cyclophosphamide led to normalization of anti-GBM antibody titers. Frequency of hemodialysis was reduced as renal function improved, and he is currently independent of dialysis with estimated glomerular filtration rate 20.7 mls/min/1.73 m 2 . Case studies in the adult literature have reported the development of a rapidly progressive anti-GBM antibody-induced glomerulonephritis following renal surgery where patients expressed HLA DR2/HLA DR15 major histocompatibility (MHC) antigens. Of note, our patient also expresses the HLA DR15 MHC antigen.

  15. Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Akiyama, Yuji; Ishifuro, Minoru; Ookubo, Masaomi [Hiroshima Univ. (Japan). Hospital] (and others)

    2002-12-01

    In recent years, laparoscopic surgery has attracted attention as a minimally invasive type of surgery because of the small surgical wounds and early recovery it provides. We carry out this technique on the basis of volume data that we make use of in multi-slice CT imaging technology in laparoscopic nephrectomy by the retroperitoneal approach, and we have created CT virtual laparoscopy by virtual endoscopic display as an intra-operative navigator with an image analysis system. We provide information on detailed vascular anatomy to form intra-operative images that act as similar support images. With the provision of this volume data, we consider virtual endoscopic display the most suitable method for surgery. When we perform virtual laparoscopy, we simulate the insertion point and angle, the order of vascular structures and their locations, the number of arteries and veins, and their bifurcation points and ligation points in conjunction with the surgeon prior to operation. As the branch patterns of the renal artery are varied, perioperative confusion and surgical mishaps can be avoided through the information that is provided beforehand. Thus surgery is more accurate and proceeds more smoothly, because the surgeon has accurate anatomical information. In addition, the time required for surgery is decreased, reducing risk and the possibility of complications. (author)

  16. Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy

    International Nuclear Information System (INIS)

    Akiyama, Yuji; Ishifuro, Minoru; Ookubo, Masaomi

    2002-01-01

    In recent years, laparoscopic surgery has attracted attention as a minimally invasive type of surgery because of the small surgical wounds and early recovery it provides. We carry out this technique on the basis of volume data that we make use of in multi-slice CT imaging technology in laparoscopic nephrectomy by the retroperitoneal approach, and we have created CT virtual laparoscopy by virtual endoscopic display as an intra-operative navigator with an image analysis system. We provide information on detailed vascular anatomy to form intra-operative images that act as similar support images. With the provision of this volume data, we consider virtual endoscopic display the most suitable method for surgery. When we perform virtual laparoscopy, we simulate the insertion point and angle, the order of vascular structures and their locations, the number of arteries and veins, and their bifurcation points and ligation points in conjunction with the surgeon prior to operation. As the branch patterns of the renal artery are varied, perioperative confusion and surgical mishaps can be avoided through the information that is provided beforehand. Thus surgery is more accurate and proceeds more smoothly, because the surgeon has accurate anatomical information. In addition, the time required for surgery is decreased, reducing risk and the possibility of complications. (author)

  17. Renal Cell Carcinoma of 4 cm or Less: An Appraisal of Its Clinical Presentation and Contemporary Surgical Management

    Directory of Open Access Journals (Sweden)

    Victor T.W. Lee

    2006-01-01

    Conclusion: A significant proportion of patients had incidental diagnosis of small renal cell carcinoma. Local control may be achieved with either radical or partial nephrectomy, with excellent survival expected.

  18. Laparoscopic Nephrectomy versus Open Nephrectomy for Patients with Autosomal Dominant Polycystic Kidney Disease: A Systematic Review and Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Pengyu Guo

    Full Text Available To compare efficacy and safety of laparoscopicnephrectomy (LN versus open nephrectomy (ON in the management of autosomal dominant polycystic kidney disease (ADPKD, we conducted a systematic review and meta-analysis.A systematic search of the electronic databases PubMed, Scopus, and the Cochrane Library was performed up to October 2014. This systematic review was performed based on observational comparative studies that assessed the two techniques. The weighted mean difference (WMD and risk ratio (RR, with their corresponding 95% confidence interval (CI, were calculated to compare continuous and dichotomous variables, respectively.Seven studies were identified, including 195 cases (118 LN/77 ON. Although LN was associated with longer operative time (WMD 30.236, 95%CI 14.541 -45.932, P<0.001 and the specimen might not have been resected as heavy as the ON group (WMD -986.516, 95%CI -1883.24--89.795, P = 0.031, patients in this group might benefit from a shorter length of hospital stay (WMD -3.576, 95%CI 4.976--2.176, P <0.001, less estimated blood loss (WMD -180.245, 95%CI -317.939--42.556, P = 0.010, and lower need of transfusion (RR 0.345, 95%CI 0.183-0.650, P = 0.001. The LN group also had less overall complications (RR 0.545, 95%CI 0.329-0.903, P = 0.018. The need of narcotic analgesics between the two groups might have no significant difference (WMD -54.66, 95%CI -129.76-20.44, P = 0.154.LN for giant symptomatic ADPKD was feasible, safe and efficacious. Morbidity was significantly reduced compared with the open approach. For an experienced laparoscopist, LN might be a better alternative.

  19. The analgesic efficacy of ultrasound-guided transversus abdominis plane block for retroperitoneoscopic donor nephrectomy: A randomized controlled study

    Directory of Open Access Journals (Sweden)

    Beena K Parikh

    2013-01-01

    Full Text Available Background: Transversus abdominis plane (TAP block is suitable for lower abdominal surgeries. Blind TAP block has many complications and uncertainty of its effects. Use of ultrasonography increases the safety and efficacy. This study was conducted to evaluate the analgesic efficacy of ultrasound (USG-guided TAP block for retroperitoneoscopic donor nephrectomy (RDN. Methods: In a prospective randomized double-blind study, 60 patients undergoing laparoscopic donor nephrectomy were randomly divided into two groups by closed envelope method. At the end of surgery, USG-guided TAP block was given to the patients of both the groups. Study group (group S received inj. Bupivacaine (0.375%, whereas control group (group C received normal saline. Inj. Tramadol (1 mg/kg was given as rescue analgesic at visual analog scale (VAS more than 3 in any group at rest or on movement. The analgesic efficacy was judged by VAS both at rest and on movement, time to first dose of rescue analgesic, cumulative dose of tramadol, sedation score, and nausea score, which were also noted at 30 min, 2, 4, 6, 12, 18, and 24 h postoperatively. Total tramadol consumption at 24 h was also assessed. Results: Patients in group S had significantly lower VAS score, longer time to first dose of rescue analgesic (547.13±266.96 min vs. 49.17±24.95 min and lower tramadol consumption (103.8±32.18 mg vs. 235.8±47.5 mg in 24 h. Conclusion: The USG-guided TAP block is easy to perform and effective as a postoperative analgesic regimen in RDN, with opioids-sparing effect and without any complications.

  20. Staged Hand-Assisted Bilateral Native Nephrectomy for Management of Posttransplant Polyuria in an Adult with Dent’s Disease

    Directory of Open Access Journals (Sweden)

    Rosa M. Montero

    2015-01-01

    Full Text Available Polyuria after kidney transplantation causes graft dysfunction and increased thrombotic risk. We present a case of a polyuric adult with Dent’s disease who underwent staged bilateral native nephrectomies, the first operation before transplant and the second four months after transplant. This led to improved allograft function maintained during four years of follow-up. The retroperitoneal laparoscopic approach was well tolerated and allowed continuation of peritoneal dialysis before transplantation. A staged approach helps regulate fluid balance perioperatively and may be tailored to individual need according to posttransplant urine output. This novel approach should be considered for polyuric patients with tubular dysfunction including Dent’s disease.

  1. Adjuvant Everolimus for Resected Kidney Cancer

    Science.gov (United States)

    In this clinical trial, patients with renal cell cancer who have undergone partial or complete nephrectomy will be randomly assigned to take everolimus tablets or matching placebo tablets daily for 54 weeks.

  2. The Effect on Survival and Mortality of the Highest SUVmax Value ...

    African Journals Online (AJOL)

    2018-02-23

    Feb 23, 2018 ... University Diyarbakir Gazi Yasargil Training and Research Hospital between. August 2007 and April .... 0.239), and a negative correlation with lung metastasis ..... Comparison of laparoscopic and open partial nephrectomies.

  3. Effect of walking speed and placement position interactions in determining the accuracy of various newer pedometers

    Directory of Open Access Journals (Sweden)

    Wonil Park

    2014-06-01

    Full Text Available Older types of pedometers had varied levels of accuracy, which ranged from 0% to 45%. In addition, to obtain accurate results, it was also necessary to position them in a certain way. By contrast, newer models can be placed anywhere on the body; however, their accuracy is unknown when they are placed at different body sites. We determined the accuracy of various newer pedometers under controlled laboratory and free walking conditions. A total of 40 participants, who varied widely in age and body mass index, were recruited for the study. The numbers of steps recorded using five different pedometers placed at the waist, the chest, in a pocket, and on an armband were compared against those counted with a hand tally counter. With the exception of one, all the pedometers were accurate at moderate walking speeds, irrespective of their placement on the body. However, the accuracy tended to decrease at slower and faster walking speeds, especially when the pedometers were worn in the pockets or kept in the purse (p < 0.05. In conclusion, most pedometers examined were accurate when they were placed at the waist, chest, and armband irrespective of the walking speed or terrain. However, some pedometers had reduced accuracy when they were kept in a pocket or placed in a purse, especially at a slower and faster walking speeds.

  4. Newer Gene Editing Technologies toward HIV Gene Therapy

    Directory of Open Access Journals (Sweden)

    Premlata Shankar

    2013-11-01

    Full Text Available Despite the great success of highly active antiretroviral therapy (HAART in ameliorating the course of HIV infection, alternative therapeutic approaches are being pursued because of practical problems associated with life-long therapy. The eradication of HIV in the so-called “Berlin patient” who received a bone marrow transplant from a CCR5-negative donor has rekindled interest in genome engineering strategies to achieve the same effect. Precise gene editing within the cells is now a realistic possibility with recent advances in understanding the DNA repair mechanisms, DNA interaction with transcription factors and bacterial defense mechanisms. Within the past few years, four novel technologies have emerged that can be engineered for recognition of specific DNA target sequences to enable site-specific gene editing: Homing Endonuclease, ZFN, TALEN, and CRISPR/Cas9 system. The most recent CRISPR/Cas9 system uses a short stretch of complementary RNA bound to Cas9 nuclease to recognize and cleave target DNA, as opposed to the previous technologies that use DNA binding motifs of either zinc finger proteins or transcription activator-like effector molecules fused to an endonuclease to mediate sequence-specific DNA cleavage. Unlike RNA interference, which requires the continued presence of effector moieties to maintain gene silencing, the newer technologies allow permanent disruption of the targeted gene after a single treatment. Here, we review the applications, limitations and future prospects of novel gene-editing strategies for use as HIV therapy.

  5. Medline Plus

    Full Text Available ... 2009) Mitral Valve Prolapse Minimally Invasive Heart Surgery: Robot Assisted Mitral Valve Repair (Baptist Health South Florida, ... Center, Merriam, KS, 05/04/2012) Kidney Cancer Robot Assisted Partial Nephrectomy Using Fluorescence (Shawnee Mission Medical ...

  6. Medline Plus

    Full Text Available ... Medical Center, Chicago, IL, 6/26/2014) Heart Failure Surgical Ventricular Reconstruction (Montefiore Medical Center, New York, ... Mission Medical Center, Merriam, KS, 05/04/2012) Kidney Cancer Robot Assisted Partial Nephrectomy Using Fluorescence (Shawnee ...

  7. Medline Plus

    Full Text Available ... Winston-Salem, NC, 09/17/2015) Kidneys and Urinary System Kidney Cancer Robot Assisted Partial Nephrectomy Using ... Norfolk General Hospital, Norfolk, VA, 3/25/2009) Urinary Incontinence Advanced Procedures in Male Incontinence: The Male ...

  8. Premalignant Lesions in the Kidney

    Directory of Open Access Journals (Sweden)

    Ziva Kirkali

    2001-01-01

    Full Text Available Renal cell carcinoma (RCC is the most malignant urologic disease. Different lesions, such as dysplasia in the tubules adjacent to RCC, atypical hyperplasia in the cyst epithelium of von Hippel-Lindau syndrome, and adenoma have been described for a number of years as possible premalignant changes or precursor lesions of RCC. In two recent papers, kidneys adjacent to RCC or removed from other causes were analyzed, and dysplastic lesions were identified and defined in detail. Currently renal intraepithelial neoplasia (RIN is the proposed term for classification. The criteria for a lesion to be defined as premalignant are (1 morphological similarity; (2 spatial association; (3 development of microinvasive carcinoma; (4 higher frequency, severity, and extent then invasive carcinoma; (5 progression to invasive cancer; and (6 similar genetic alterations. RIN resembles the neoplastic cells of RCC. There is spatial association. Progression to invasive carcinoma is described in experimental cancer models, and in some human renal tumors. Similar molecular alterations are found in some putative premalignant changes. The treatment for RCC is radical or partial nephrectomy. Preneoplastic lesions may remain in the renal remnant in patients treated by partial nephrectomy and may be the source of local recurrences. RIN seems to be a biologic precursor of some RCCs and warrants further investigation. Interpretation and reporting of these lesions would reveal important resources for the biological nature and clinical significance. The management of RIN diagnosed in a renal biopsy and partial nephrectomy needs to be answered.

  9. Radiosensitization of renal cell carcinoma in vitro through the induction of autophagy

    International Nuclear Information System (INIS)

    Anbalagan, Selvakumar; Pires, Isabel M.; Blick, Christopher; Hill, Mark A.; Ferguson, David J.P.; Chan, Denise A.; Hammond, Ester M.

    2012-01-01

    Background and purpose: For patients diagnosed with advanced renal cell carcinoma (RCC), there are few therapeutic options. Radiation therapy is predominantly used to treat metastasis and has not proven effective in the adjuvant setting for renal cancer. Furthermore, RCC is resistant to standard cytotoxic chemotherapies. Targeted anti-angiogenics are the standard of care for RCC but are not curative. Newer agents, such as mTOR inhibitors and others that induce autophagy, have shown great promise for treating RCC. Here, we investigate the potential use of the small molecule STF-62247 to modulate radiation. Materials and methods: Using RCC cell lines, we evaluate sensitivity to radiation in addition to agents that induce autophagic cell death by clonogenic survival assays. Furthermore, these were also tested under physiological oxygen levels. Results: STF-62247 specifically induces autophagic cell death in cells that have lost VHL, an essential mutation in the development of RCC. Treatment with STF-62247 did not alter cell cycle progression but when combined with radiation increased cell killing under oxic and hypoxic/physiological conditions. Conclusions: This study highlights the possibility of combining targeted therapeutics such as STF-62247 or temsirolimus with radiation to reduce the reliance on partial or full nephrectomy and improve patient prognosis.

  10. Ethical issues in newer assisted reproductive technologies: A view from Nigeria.

    Science.gov (United States)

    Fadare, J O; Adeniyi, A A

    2015-12-01

    Infertility is a prevalent condition in many developing countries with significant physical and psychosocial implications. The aim of this study is to discuss briefly the ethics of newer assisted reproductive technology (ART) with special emphasis on the peculiarities in Nigeria. MEDLINE and Google Scholar were searched for English-language articles from January 1990 to July 2014 using the search terms "ethics of ART AND Nigeria," "ethical issues in in vitro fertilization AND Nigeria." Using the above search phrases, a total of 43 articles were retrieved out of which only 5 dealt specifically with the subject matter. The core ethical issues found in the reviewed literature are listed in [Table 1]. Inequitable access to ART due to its high cost, lack of regulatory body, safety of the procedure, and fate of the embryos were the main themes identified from the papers. Surrogacy, sex selection, and gamete donation were additional relevant ethical issues. There is an urgent need for stakeholders in developing countries to formulate cultural and context-specific guidelines to help address some of these ethical dilemmas.

  11. Development of a human cadaver model for training in laparoscopic donor nephrectomy.

    Science.gov (United States)

    Sutton, Erica R H; Billeter, Adrian; Druen, Devin; Roberts, Henry; Rice, Jonathan

    2017-06-01

    The organ procurement network recommends a surgeon record 15 cases as surgeon or assistant for laparoscopic donor nephrectomies (LDN) prior to independent practice. The literature suggests that the learning curve for improved perioperative and patient outcomes is closer to 35 cases. In this article, we describe our development of a model utilizing fresh tissue and objective, quantifiable endpoints to document surgical progress, and efficiency in each of the major steps involved in LDN. Phase I of model development focused on the modifications necessary to maintain visualization for laparoscopic surgery in a human cadaver. Phase II tested proposed learner-based metrics of procedural competency for multiport LDN by timing procedural steps of LDN in a novice learner. Phases I and II required 12 and nine cadavers, with a total of 35 kidneys utilized. The following metrics improved with trial number for multiport LDN: time taken for dissection of the gonadal vein, ureter, renal hilum, adrenal and lumbrical veins, simulated warm ischemic time (WIT), and operative time. Human cadavers can be used for training in LDN as evidenced by improvements in timed learner-based metrics. This simulation-based model fills a gap in available training options for surgeons. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Deregulated Renal Calcium and Phosphate Transport during Experimental Kidney Failure

    NARCIS (Netherlands)

    Pulskens, W.P.C.; Verkaik, M.; Sheedfar, F.; Loon, E.P.M. van; Sluis, B. van de; Vervloet, M.G.; Hoenderop, J.G.J.; Bindels, R.J.M.

    2015-01-01

    Impaired mineral homeostasis and inflammation are hallmarks of chronic kidney disease (CKD), yet the underlying mechanisms of electrolyte regulation during CKD are still unclear. Here, we applied two different murine models, partial nephrectomy and adenine-enriched dietary intervention, to induce

  13. Towards a standardised informed consent procedure for live donor nephrectomy: the PRINCE (Process of Informed Consent Evaluation) project-study protocol for a nationwide prospective cohort study.

    Science.gov (United States)

    Kortram, Kirsten; Spoon, Emerentia Q W; Ismail, Sohal Y; d'Ancona, Frank C H; Christiaans, Maarten H L; van Heurn, L W Ernest; Hofker, H Sijbrand; Hoksbergen, Arjan W J; Homan van der Heide, Jaap J; Idu, Mirza M; Looman, Caspar W N; Nurmohamed, S Azam; Ringers, Jan; Toorop, Raechel J; van de Wetering, Jacqueline; Ijzermans, Jan N M; Dor, Frank J M F

    2016-04-01

    Informed consent is mandatory for all (surgical) procedures, but it is even more important when it comes to living kidney donors undergoing surgery for the benefit of others. Donor education, leading to informed consent, needs to be carried out according to certain standards. Informed consent procedures for live donor nephrectomy vary per centre, and even per individual healthcare professional. The basis for a standardised, uniform surgical informed consent procedure for live donor nephrectomy can be created by assessing what information donors need to hear to prepare them for the operation and convalescence. The PRINCE (Process of Informed Consent Evaluation) project is a prospective, multicentre cohort study, to be carried out in all eight Dutch kidney transplant centres. Donor knowledge of the procedure and postoperative course will be evaluated by means of pop quizzes. A baseline cohort (prior to receiving any information from a member of the transplant team in one of the transplant centres) will be compared with a control group, the members of which receive the pop quiz on the day of admission for donor nephrectomy. Donor satisfaction will be evaluated for all donors who completed the admission pop-quiz. The primary end point is donor knowledge. In addition, those elements that have to be included in the standardised format informed consent procedure will be identified. Secondary end points are donor satisfaction, current informed consent practices in the different centres (eg, how many visits, which personnel, what kind of information is disclosed, in which format, etc) and correlation of donor knowledge with surgeons' estimation thereof. Approval for this study was obtained from the medical ethical committee of the Erasmus MC, University Medical Center, Rotterdam, on 18 February 2015. Secondary approval has been obtained from the local ethics committees in six participating centres. Approval in the last centre has been sought. Outcome will be published in a

  14. Hilar control during laparoscopic donor nephrectomy: Practice patterns in Canada.

    Science.gov (United States)

    Mcgregor, Thomas B; Patel, Premal; Chan, Gabriel; Sener, Alp

    2017-10-01

    In recent years, the method of vascular control during laparoscopic donor nephrectomy (LDN) has come under scrutiny due to catastrophic consequences of a device failure. This study sought to examine the surgical preferences of Canadian donor surgeons with regards to vascular control and their perception on the safety of these modalities. We also surveyed the experience with device malfunction and their subsequent management during LDN. An online survey was sent out to donor surgeons registered with the Canadian Society of Transplantation. Surveys were anonymous and voluntary. Descriptive statistics were used to analyze the collected responses. Recollection of the sequelae and outcomes from device malfunction were also queried. Twenty-eight of 37 surgeons (76% response rate) responded to the survey. At least one surgeon from every institution in Canada performing LDN responded to the survey. Laparoscopic stapler is the most commonly used device for securing the renal artery (61%) and renal vein (67%). Overall, surgeons felt the stapler was the safest method of securing the renal artery. Stapler misfire and clip slippage were reported by eight (28.5%) and 12 (43%) surgeons, respectively. Most cases were salvageable: laparoscopically (30%), open conversion (30%), and by hand port (5%). Slippage of a plastic locking clip resulted in one emergent laparotomy on POD#1 and one stapler misfire was converted to open resulting in donor death. Although rare, hemorrhagic complications can occur from device malfunction resulting in poor outcomes for healthy volunteers undergoing LDN. Surgeons need to remain vigilant when selecting the appropriate modality for vascular control.

  15. Two Different Maintenance Strategies in the Hospital Environment: Preventive Maintenance for Older Technology Devices and Predictive Maintenance for Newer High-Tech Devices.

    Science.gov (United States)

    Sezdi, Mana

    2016-01-01

    A maintenance program generated through the consideration of characteristics and failures of medical equipment is an important component of technology management. However, older technology devices and newer high-tech devices cannot be efficiently managed using the same strategies because of their different characteristics. This study aimed to generate a maintenance program comprising two different strategies to increase the efficiency of device management: preventive maintenance for older technology devices and predictive maintenance for newer high-tech devices. For preventive maintenance development, 589 older technology devices were subjected to performance verification and safety testing (PVST). For predictive maintenance development, the manufacturers' recommendations were used for 134 high-tech devices. These strategies were evaluated in terms of device reliability. This study recommends the use of two different maintenance strategies for old and new devices at hospitals in developing countries. Thus, older technology devices that applied only corrective maintenance will be included in maintenance like high-tech devices.

  16. Peritoneal Dialysis and Retroperitoneal Laparoscopic Radical Nephrectomy: A Favorable Experience With a Patient Complicated by Renal Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Reika Imai

    2017-12-01

    Full Text Available Peritoneal dialysis (PD is an accepted modality for managing end-stage kidney disease. We herein report a 75-year-old female patient on chronic PD who was complicated by renal cell carcinoma. She was successfully treated with retroperitoneal laparoscopic radical nephrectomy followed by a prompt resumption of the procedure. Various surgeries disturbing the abdominal wall integrity often disrupt the regular PD schedule, and using minimally invasive approaches is therefore an attractive therapeutic option. Our experience emphasizes the feasibility and safety of a retroperitoneal approach–based laparoscopic technique based on several empirical examples. However, systemic studies on this topic are obviously lacking, so we strongly recommend the accumulation of more cases similar to our own. Several surgical concerns that need to be dealt with among PD patients are also discussed.

  17. Prevalence, correlates, and impact of coronary calcification on adverse events following PCI with newer-generation DES: Findings from a large multiethnic registry.

    Science.gov (United States)

    Copeland-Halperin, Robert S; Baber, Usman; Aquino, Melissa; Rajamanickam, Anitha; Roy, Swathi; Hasan, Choudhury; Barman, Nitin; Kovacic, Jason C; Moreno, Pedro; Krishnan, Prakash; Sweeny, Joseph M; Mehran, Roxana; Dangas, George; Kini, Annapoorna S; Sharma, Samin K

    2018-04-01

    We sought to determine the prevalence, predictors, and clinical impact of target lesion calcification in patients undergoing percutaneous coronary intervention (PCI) with newer generation drug-eluting stents (DES) and devices. Coronary calcification is independently associated with adverse outcomes following PCI. While newer DES and contemporary devices are considered safer and more efficacious, their influence on outcomes following PCI of heavily calcified lesions is unknown. We performed a retrospective analysis of a large, multiethnic cohort of patients undergoing PCI with new generation DES at an academic center between 2009 and 2013. Coronary calcification was qualitatively assessed as none/mild, moderate, or severe. Independent demographic, clinical, and anatomic predictors of moderate/severe calcification were identified using logistic regression. Associations between coronary calcification and 1-year MACE (death, myocardial infarction, or target vessel revascularization) were examined using Cox modeling. Compared to patients with none/mild (n = 10,180; 82.0%), those with moderate (n = 1,271; 10.0%) or severe (n = 994; 8.0%) calcification were older, more often Caucasian, had more complex target lesions, and worse renal function. The strongest demographic, clinical, and anatomic correlates of moderate/severe calcification were age, Caucasian race, renal dysfunction, lesion length, and left main location. Unadjusted MACE rates among those with none/mild, moderate, and severe calcification were 8.3, 14.6, and 17.8%, respectively (P < 0.001). After multivariable adjustment, the hazard ratio (95% CI) for MACE associated with moderate or severe coronary calcification was 1.63. Target lesion calcification remains independently associated with adverse outcomes in patients treated with newer generation DES and modern devices. © 2017 Wiley Periodicals, Inc.

  18. Use of bipolar radiofrequency in parenchymal transection of the liver, pancreas and kidney.

    Science.gov (United States)

    Pai, Madhava; Spalding, Duncan; Jiao, Long; Habib, Nagy

    2012-01-01

    Intraoperative blood loss has been shown to be an important factor correlating with increased morbidity and mortality in oncological surgery. Despite technological advances in parenchymal transection devices, bleeding remains the single most important complication. To address this, we designed and developed a bipolar radiofrequency (RF) device, the Habib 4X (Angiodynamics, Inc., Queensbury, N.Y., USA), which was initially used specifically for liver resections. A search using Medline, Embase and Google™ Scholar was performed for the period January 2001 to August 2011. The following Mesh terms were used: 'bipolar radiofrequency', 'Habib 4X', 'laparoscopic', 'liver resection', 'partial nephrectomy' and 'distal pancreatectomy'. The references of the studies included were also reviewed. Series from our centre were excluded. There were seven series published, reporting a total of 188 liver resections [113 minor (Habib 4X) device over this period. The median blood loss reported ranged from 15 to 427 ml with a transfusion rate of 0-14% In addition, five series of partial nephrectomies were also identified, reporting a total of 149 (45 open and 104 laparoscopic) cases. Hilar clamping was not used in any of the cases, and the mean blood loss reported was 100-337 ml whilst the transfusion rate ranged from 0 to 7.1%. There was only one published series of distal pancreatectomies; these were laparoscopic and included 14 patients. This review of bipolar RF-assisted liver resections, partial nephrectomies and distal pancreatectomies reported in the literature to date shows that there are significant advantages in using this device in these types of operation. Copyright © 2012 S. Karger AG, Basel.

  19. Oxcarbazepine versus carbamazepine monotherapy for partial onset seizures.

    Science.gov (United States)

    Koch, Marcus W; Polman, Susanne Kl

    2009-10-07

    Partial onset seizures are often treated with the standard antiepileptic drug carbamazepine. Oxcarbazepine is a newer antiepileptic drug related to carbamazepine that is claimed to be better tolerated. To compare efficacy and tolerability of carbamazepine and oxcarbazepine monotherapy for partial onset seizures. We searched the Cochrane Epilepsy Group Specialised Register (4 August 2009), the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library issue 3, 2009), MEDLINE (January 1966 to May 2008), reference lists of relevant articles and conference proceedings. We also contacted manufacturers and researchers in the field for published or unpublished data. Blinded and unblinded randomised controlled trials of carbamazepine versus oxcarbazepine monotherapy for partial onset seizures. Both authors independently assessed trial quality, according to the guidelines in the Cochrane Reviewer's Handbook, and extracted information about study population, type of intervention, outcome measures and study design. All analyses in this review are by intention-to-treat. We tested for statistical heterogeneity among the identified studies using the chi-squared test. Three trials (723 participants) were included. Only one trial used adequate outcome measures of efficacy; therefore, the results pertaining to efficacy are based on a single trial, whereas the results pertaining to adverse events are based on all three included trials. There was no overall difference in time to treatment withdrawal between the two drugs (hazard ratio (HR) of oxcarbazepine (OXC) versus carbamazepine (CBZ): 1.04, 95% confidence interval (CI) 0.78 to 1.39). Further analyses showed no significant difference in treatment withdrawal for unacceptable side effects (HR of OXC versus CBZ: 0.85, 95% CI 0.59 to 1.24) and in treatment withdrawal for inadequate seizure control (HR of OXC versus CBZ: 1.33, 95% CI 0.82 to 2.15). Oxcarbazepine and carbamazepine appeared to be similarly effective

  20. Cytokine-Modulating Strategies and Newer Cytokine Targets for Arthritis Therapy

    Directory of Open Access Journals (Sweden)

    Shivaprasad H. Venkatesha

    2014-12-01

    Full Text Available Cytokines are the key mediators of inflammation in the course of autoimmune arthritis and other immune-mediated diseases. Uncontrolled production of the pro-inflammatory cytokines such as interferon-γ (IFN-γ, tumor necrosis factor α (TNFα, interleukin-6 (IL-6, and IL-17 can promote autoimmune pathology, whereas anti-inflammatory cytokines including IL-4, IL-10, and IL-27 can help control inflammation and tissue damage. The pro-inflammatory cytokines are the prime targets of the strategies to control rheumatoid arthritis (RA. For example, the neutralization of TNFα, either by engineered anti-cytokine antibodies or by soluble cytokine receptors as decoys, has proven successful in the treatment of RA. The activity of pro-inflammatory cytokines can also be downregulated either by using specific siRNA to inhibit the expression of a particular cytokine or by using small molecule inhibitors of cytokine signaling. Furthermore, the use of anti-inflammatory cytokines or cytokine antagonists delivered via gene therapy has proven to be an effective approach to regulate autoimmunity. Unexpectedly, under certain conditions, TNFα, IFN-γ, and few other cytokines can display anti-inflammatory activities. Increasing awareness of this phenomenon might help develop appropriate regimens to harness or avoid this effect. Furthermore, the relatively newer cytokines such as IL-32, IL-34 and IL-35 are being investigated for their potential role in the pathogenesis and treatment of arthritis.

  1. Production and partial purification of glucoamylase from Aspergillus ...

    African Journals Online (AJOL)

    SAM

    2014-05-21

    May 21, 2014 ... producing ability on potato dextrose agar using plate assay method fortified with starch agar, and ... under the terms of the Creative Commons Attribution License ... the process cost, consequently, the search for newer glu-.

  2. Twelve-year survival after multiple recurrences and repeated metastasectomies for renal cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Wang Jue

    2011-11-01

    Full Text Available Abstract Background Metastatic renal cell carcinoma (RCC presents a therapeutic challenge for clinicians because of the unpredictable clinical course, resistance to chemotherapy or radiotherapy and the limited response to immunotherapy. Patients and Methods We report a case of a 62-year-old woman who underwent nephrectomy for T4N0 RCC, clear cell type, Fuhrman grade 3/4 in 1999. The patinet subsequently had multiple tumor recurrences. Results The patient underwent eight metastasectomies, including multiple partial left nephrectomies, right adrenalectomy, a complete left nephrectomy, and distal pancreatectomy. She remains well and tumor free 12 years after initial diagnosis. Conclusion Repeated resections after initial metastasectomy can be carried out safely and provide long-term survival in selected patients with recurrent metastasis from RCC. The findings from our case indicate that close follow-up for the early detection of recurrence and complete resection of metastases can improve the results after repeated resection.

  3. Renal lymph nodes for tumor staging: appraisal of 871 nephrectomies with examination of hilar fat.

    Science.gov (United States)

    Mehta, Vikas; Mudaliar, Kumaran; Ghai, Ritu; Quek, Marcus L; Milner, John; Flanigan, Robert C; Picken, Maria M

    2013-11-01

    Despite decades of research, the role of lymphadenectomy in the management of renal cell carcinoma (RCC) is still not clearly defined. Before the implementation of targeted therapies, lymph node metastases were considered to be a portent of markedly decreased survival, regardless of the tumor stage. However, the role of lymphadenectomy and the relative benefit of retroperitoneal lymph node dissection in the context of modern adjunctive therapies have not been conclusively addressed in the clinical literature. The current pathologic literature does not offer clear recommendations with regard to the minimum number of lymph nodes that should be examined in order to accurately stage the pN in renal cell carcinoma. Although gross examination of the hilar fat to assess the nodal status is performed routinely, it has not yet been determined whether this approach is adequate. To evaluate the status of lymph nodes and their rate of identification in the pathologic examination of nephrectomy specimens in adult renal malignancies. We reviewed the operative and pathology reports of 871 patients with renal malignancies treated by nephrectomy. All tumors were classified according to the seventh edition of the Tumor-Nodes-Metastasis classification. Patients were divided into 3 groups: Nx, no lymph nodes recovered; N0, negative; and N1, with positive lymph nodes. Grossly visible lymph nodes were submitted separately; as per grossing protocol, hilar fatty tissue was submitted for microscopic examination. We evaluated the factors that affected the number of lymph nodes identified and the variables that allowed the prediction of nodal involvement. Lymph nodes were recovered in 333 of 871 patients (38%): hilar in 125 patients, nonhilar in 137 patients, and hilar and nonhilar in 71 patients. Patients with positive lymph nodes (n = 87) were younger, had larger primary tumors, and had lymph nodes of average size, as well as a higher pT stage, nuclear grade, and rate of metastases

  4. Diagnostic accuracy of a volume-rendered computed tomography movie and other computed tomography-based imaging methods in assessment of renal vascular anatomy for laparoscopic donor nephrectomy.

    Science.gov (United States)

    Yamamoto, Shingo; Tanooka, Masao; Ando, Kumiko; Yamano, Toshiko; Ishikura, Reiichi; Nojima, Michio; Hirota, Shozo; Shima, Hiroki

    2009-12-01

    To evaluate the diagnostic accuracy of computed tomography (CT)-based imaging methods for assessing renal vascular anatomy, imaging studies, including standard axial CT, three-dimensional volume-rendered CT (3DVR-CT), and a 3DVR-CT movie, were performed on 30 patients who underwent laparoscopic donor nephrectomy (10 right side, 20 left side) for predicting the location of the renal arteries and renal, adrenal, gonadal, and lumbar veins. These findings were compared with videos obtained during the operation. Two of 37 renal arteries observed intraoperatively were missed by standard axial CT and 3DVR-CT, whereas all arteries were identified by the 3DVR-CT movie. Two of 36 renal veins were missed by standard axial CT and 3DVR-CT, whereas 1 was missed by the 3DVR-CT movie. In 20 left renal hilar anatomical structures, 20 adrenal, 20 gonadal, and 22 lumbar veins were observed during the operation. Preoperatively, the standard axial CT, 3DVR-CT, and 3DVR-CT movie detected 11, 19, and 20 adrenal veins; 13, 14, and 19 gonadal veins; and 6, 11, and 15 lumbar veins, respectively. Overall, of 135 renal vascular structures, the standard axial CT, 3DVR-CT, and 3DVR-CT movie accurately detected 99 (73.3%), 113 (83.7%), and 126 (93.3%) vessels, respectively, which indicated that the 3DVR-CT movie demonstrated a significantly higher detection rate than other CT-based imaging methods (P renal vascular anatomy before laparoscopic donor nephrectomy.

  5. An adjuvant autologous therapeutic vaccine (HSPPC-96; vitespen) versus observation alone for patients at high risk of recurrence after nephrectomy for renal cell carcinoma: a multicentre, open-label, randomised phase III trial.

    Science.gov (United States)

    Wood, Christopher; Srivastava, Pramod; Bukowski, Ronald; Lacombe, Louis; Gorelov, Andrei I; Gorelov, Sergei; Mulders, Peter; Zielinski, Henryk; Hoos, Axel; Teofilovici, Florentina; Isakov, Leah; Flanigan, Robert; Figlin, Robert; Gupta, Renu; Escudier, Bernard

    2008-07-12

    Treatment of localised renal cell carcinoma consists of partial or radical nephrectomy. A substantial proportion of patients are at risk for recurrence because no effective adjuvant therapy exists. We investigated the use of an autologous, tumour-derived heat-shock protein (glycoprotein 96)-peptide complex (HSPPC-96; vitespen) as adjuvant treatment in patients at high risk of recurrence after resection of locally advanced renal cell carcinoma. In this open-label trial, patients were randomly assigned to receive either vitespen (n=409) or observation alone (n=409) after nephrectomy. Randomisation was done in a one to one ratio by a computer-generated pseudo-random number generator, with a block size of four, and was stratified by performance score, lymph node status, and nuclear grade. Vitespen was given intradermally once a week for 4 weeks, then every 2 weeks until vaccine depletion. The primary endpoint was recurrence-free survival. The final analysis of recurrence-free survival was planned to take place after 214 or more events of disease recurrence or deaths before recurrence had occurred. Analysis was by intention to treat (ITT). This study is registered with ClinicalTrials.gov, number NCT00033904. 48 patients in the vitespen group and 42 in the observation group were excluded from the ITT population because they did not meet post-surgery inclusion criteria; the ITT population thus consisted of 361 patients in the vitespen group and 367 in the observation group. Final analysis of recurrence-free survival was triggered in November, 2005. Re-review of all patients in the ITT population by the clinical events committee identified 149 actual recurrences (73 in the vitespen group and 76 in the observation group), nine deaths before recurrence (two in the vitespen group and seven in the observation group), and 124 patients with baseline metastatic or residual disease (61 in the vitespen group and 63 in the observation group). Thus, after a median follow-up of 1

  6. Study of adverse events following immunisation with universal and newer vaccines in the Serampore IMA Child Clinic over a period of 7 years.

    Science.gov (United States)

    Das, Pradip Kumar

    2013-04-01

    Immunisation is an important part of childcare practice. It is one of the most beneficial and cost effective measures for the prevention of diseases. From the previous retrospective studies, it was evident that smallpox has been completely eradicated throughout now-a-days with the wholehearted and sincere efforts of healthcare providers by applying efficient and safe vaccine against smallpox, same is true also to polio which is now close to worldwide eradication and measles and rubella are no longer endemic in certain parts of the world. Not only has that with the introduction of safer and more efficient newer vaccines, the incidence of most other vaccine preventable disease of childhood also reduced considerably. The aim of the present study is to estimate the incidence and clinical presentation of adverse events following immunisation with universal and newer vaccines for a period of seven years using prospective active surveillance. Children under the age of 7 years were taken for universal and newer scheduled vaccinations given in the Serampore IMA Child Clinic under the supervision of the clinicians maintaining strictly the guidelines of Expanded Programme of Immunisation (Government of India). This study of adverse events following immunisation in the Serampore IMA Child Clinic confirms that the adverse events such as fever (0.37%), pain and swelling at the site of injection (0.32%0, urticarial rash (0.02%), anaphylactic shock (0.003%) are negligible. There were only two reports of anaphylaxis following preschool and infant schedule vaccines, including measles, mumps and rubella (MMR), Haemophilus influenzae type B vaccines and typhoid vaccines in approximately 52,000 infants received over a period of 7 years starting from 1st April, 2005 to 31st March, 2012 and there were no deaths or longterm effects reported during the post follow-up period in the Serampore IMA Child Clinic.

  7. A novel robotic system for single-port urologic surgery: first clinical investigation.

    Science.gov (United States)

    Kaouk, Jihad H; Haber, Georges-Pascal; Autorino, Riccardo; Crouzet, Sebastien; Ouzzane, Adil; Flamand, Vincent; Villers, Arnauld

    2014-12-01

    The idea of performing a laparoscopic procedure through a single abdominal incision was conceived with the aim of expediting postoperative recovery. To determine the clinical feasibility and safety of single-port urologic procedures by using a novel robotic surgical system. This was a prospective institutional review board-approved, Innovation, Development, Exploration, Assessment, Long-term Study (IDEAL) phase 1 study. After enrollment, patients underwent a major urologic robotic single-port procedure over a 3-wk period in July 2010. The patients were followed for 3 yr postoperatively. Different types of urologic surgeries were performed using the da Vinci SP Surgical System. This system is intended to provide the same core clinical capabilities as the existing multiport da Vinci system, except that three articulating endoscopic instruments and an articulating endoscopic camera are inserted into the patient through a single robotic port. The main outcomes were the technical feasibility of the procedures (as measured by the rate of conversions) and the safety of the procedures (as measured by the incidence of perioperative complications). Secondary end points consisted of evaluating other key surgical perioperative outcomes as well as midterm functional and oncologic outcomes. A total of 19 patients were enrolled in the study. Eleven of them underwent radical prostatectomy; eight subjects underwent nephrectomy procedures (partial nephrectomy, four; radical nephrectomy, two; and simple nephrectomy, two). There were no conversions to alternative surgical approaches. Overall, two major (Clavien grade 3b) postoperative complications were observed in the radical prostatectomy group and none in the nephrectomy group. At 1-yr follow-up, one radical prostatectomy patient experienced biochemical recurrence, which was successfully treated with salvage radiation therapy. The median warm ischemia time for three of the partial nephrectomies was 38 min. At 3-yr follow-up all

  8. The Management of Synchronous Bilateral Wilms Tumor: A Report from the National Wilms Tumor Study Group

    Science.gov (United States)

    Hamilton, Thomas E.; Ritchey, Michael L.; Haase, Gerald M.; Argani, Pedram; Peterson, Susan M.; Anderson, James R.; Green, Daniel M.; Shamberger, Robert C.

    2013-01-01

    Objective To provide guidelines for future trials, we reviewed the outcomes of children with synchronous bilateral Wilms tumors (BWT) treated on National Wilms Tumor Study-4 (NWTS-4). Methods NWTS-4 enrolled 3,335 patients (pts) including 188 pts with BWT (5.6%). Treatment and outcome data were collected. Results Among 188 BWT pts registered with NWTS-4, 195 kidneys in 123 patients had initial open biopsy, 44 kidneys in 31 pts had needle biopsies. Although pre-resection chemotherapy was recommended, 87 kidneys in 83 pts were managed with primary resection: Complete nephrectomy 48 in 48 pts, 31 partial/wedge nephrectomies in 27 pts, enucleations 8 in 8 pts. No initial surgery was performed in 45 kidneys in 43 pts, 5 kidneys in 3 pts not coded. Anaplasia was diagnosed after completion of the initial course of chemotherapy in 14 pts (initial surgical procedure: 9 open biopsies, 4 needle biopsies, 1 partial nephrectomy). The average number of days from the start of chemotherapy to diagnosis of anaplasia was 390 (range 44–1,925 days). Relapse or progression of disease occurred in 54 children. End stage renal failure occurred in 23 children, 6 of whom had bilateral nephrectomies. The 8 year event free survival (EFS) for BWT with favorable histology was 74%, and overall survival (OS) was 89%; while the EFS for BWT with unfavorable histology was 40%, OS was 45%. Conclusion The current analysis of patients with BWT treated on NWTS-4 shows that preservation of renal parenchyma is possible in many pts following initial preoperative chemotherapy. The incidence of end-stage renal disease remains significantly higher in children with BWT. Future studies are warranted to address the need for earlier biopsy in non-responsive tumors and earlier definitive surgery to recognize unfavorable histology in these high risk patients. PMID:21394016

  9. 3D-printed soft-tissue physical models of renal malignancies for individualized surgical simulation: a feasibility study.

    Science.gov (United States)

    Maddox, Michael M; Feibus, Allison; Liu, James; Wang, Julie; Thomas, Raju; Silberstein, Jonathan L

    2018-03-01

    To construct patient-specific physical three-dimensional (3D) models of renal units with materials that approximates the properties of renal tissue to allow pre-operative and robotic training surgical simulation, 3D physical kidney models were created (3DSystems, Rock Hill, SC) using computerized tomography to segment structures of interest (parenchyma, vasculature, collection system, and tumor). Images were converted to a 3D surface mesh file for fabrication using a multi-jet 3D printer. A novel construction technique was employed to approximate normal renal tissue texture, printers selectively deposited photopolymer material forming the outer shell of the kidney, and subsequently, an agarose gel solution was injected into the inner cavity recreating the spongier renal parenchyma. We constructed seven models of renal units with suspected malignancies. Partial nephrectomy and renorrhaphy were performed on each of the replicas. Subsequently all patients successfully underwent robotic partial nephrectomy. Average tumor diameter was 4.4 cm, warm ischemia time was 25 min, RENAL nephrometry score was 7.4, and surgical margins were negative. A comparison was made between the seven cases and the Tulane Urology prospectively maintained robotic partial nephrectomy database. Patients with surgical models had larger tumors, higher nephrometry score, longer warm ischemic time, fewer positive surgical margins, shorter hospitalization, and fewer post-operative complications; however, the only significant finding was lower estimated blood loss (186 cc vs 236; p = 0.01). In this feasibility study, pre-operative resectable physical 3D models can be constructed and used as patient-specific surgical simulation tools; further study will need to demonstrate if this results in improvement of surgical outcomes and robotic simulation education.

  10. Prevention of reflex natriuresis after acute unilateral nephrectomy by neonatal administration of MSG

    International Nuclear Information System (INIS)

    Lin, S.Y.; Wiedemann, E.; Deschepper, C.F.; Alper, R.H.; Humphreys, M.H.

    1987-01-01

    Acute unilateral nephrectomy (AUN) results in natriuresis from the remaining kidney through reflex pathways involving the central nervous system and requiring an intact pituitary gland. The natriuresis is accompanied by an increase in the plasma concentration of a peptide or peptides derived from the N-terminal fragment (NTF) of proopiomelanocortin. The authors measured plasma immunoreactive NTF-like material (IR-NTF) by radioimmunoassay, before and after AUN in control rats and rats treated neonatally with monosodium glutamate (MSG), a procedure that produces neuroendocrine dysfunction by destroying cell bodies in the hypothalamic arcuate nucleus, median eminence, and other brain regions. In control rats, IR-NTF increased from 85.8 +/- 54.9 (SD) to 207 +/- 98.1 fmol/ml after AUN as sodium excretion (U/sub Na/V) doubled. In MSG-treated rats, AUN produced no change in plasma IR-NTF concentration, nor did U/sub Na/V increase. Tissue content of IR-NTF was reduced in the arcuate nucleus and anterior lobe of pituitaries from MSG-treated rats compared with controls, but was no different in the neurointermediate lobe. These results indicate that the hypothalamic lesion produced by neonatal administration of MSG prevents both the increase in plasma IR-NTF concentration and the natruiuresis after AUN, and therefore lend further support to the concept of a casual relationship between these two consequences of AUN

  11. [Preoperative assessment of renal vascular anatomy for donor nephrectomy: Is CT superior to MRI?].

    Science.gov (United States)

    Arvin-Berod, A; Bricault, I; Terrier, N; Skowron, O; Cadi, P; Boillot, B; Thuillier, C; Cluze, C; Descotes, J-L; Rambeaud, J-J; Long, J-A

    2011-01-01

    computed tomography angiography (CTA) and magnetic resonance angiography (MRA) are both used in the preoperative assessment of vascular anatomy before donor nephrectomy. Our objective was to determine retrospectively and to compare the sensitivity of CTA and MRA imaging in preoperative renal vascularisation in living kidney donors. between 1999 and 2007, 42 kidney donors were assessed in our center: 27 by MRA, 10 by CTA, and five by both techniques. Images were interpreted using multiplanar reconstructions. Results were compared retrospectively with peroperative findings; discordant cases were re-examined by an experienced radiologist. Numbers of vessels detected with imaging methods was compared with numbers actually found at the operating time. MRA showed 35/43 arteries (Se 81.4 %) and 33/34 veins (Se 97.1 %), and CTA showed 18/18 arteries (Se 100 %) and 15/16 veins (Se 93.8 %). The presence of multiple arteries was detected in only one third of cases (3/9) on MRI scans; this difference was statistically significant. The missed arteries were not detected on second examination of the MRI scans with the knowledge of peroperative findings. MRA is less sensitive than CTA for preoperative vascularisation imaging in living renal donors, especially in the detection of multiple renal arteries. 2010 Elsevier Masson SAS. All rights reserved.

  12. Outcomes of Patients with Renal Cell Carcinoma and Sarcomatoid Dedifferentiation Treated with Nephrectomy and Systemic Therapies: Comparison between the Cytokine and Targeted Therapy Eras.

    Science.gov (United States)

    Keskin, Sarp K; Msaouel, Pavlos; Hess, Kenneth R; Yu, Kai-Jie; Matin, Surena F; Sircar, Kanishka; Tamboli, Pheroze; Jonasch, Eric; Wood, Christopher G; Karam, Jose A; Tannir, Nizar M

    2017-09-01

    We studied overall survival and prognostic factors in patients with sarcomatoid renal cell carcinoma treated with nephrectomy and systemic therapy in the cytokine and targeted therapy eras. This is a retrospective study of patients with sarcomatoid renal cell carcinoma who underwent nephrectomy and received systemic therapy at our center in the cytokine era (1987 to 2005) or the targeted therapy era (2006 to 2015). Multivariate regression models were used to determine the association of covariables with survival. Of the 199 patients with sarcomatoid renal cell carcinoma 167 (83.9%) died (median overall survival 16.5 months, 95% CI 15.2-20.9). Survival of patients with clear cell histology was significantly longer vs those with nonclear cell histology (p = 0.034). Patients with synchronous metastatic disease had significantly shorter survival than patients with metachronous metastatic disease (median 12.1 vs 23.3 months, p = 0.0064). Biopsy of the primary tumor or a metastatic site could detect the presence of sarcomatoid features in only 7.5% of cases. Although a significant improvement in survival rate was observed in the first year in patients treated in the targeted therapy era (p = 0.011), this effect was attenuated at year 2, disappeared at years 3 to 5 after diagnosis and was not evident in patients with poor risk features. Patients with sarcomatoid renal cell carcinoma still have poor prognosis with no clear long-term benefit of targeted therapy. This underscores the need to develop more effective systemic therapies for these patients. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. Two Different Maintenance Strategies in the Hospital Environment: Preventive Maintenance for Older Technology Devices and Predictive Maintenance for Newer High-Tech Devices

    OpenAIRE

    Sezdi, Mana

    2016-01-01

    A maintenance program generated through the consideration of characteristics and failures of medical equipment is an important component of technology management. However, older technology devices and newer high-tech devices cannot be efficiently managed using the same strategies because of their different characteristics. This study aimed to generate a maintenance program comprising two different strategies to increase the efficiency of device management: preventive maintenance for older tec...

  14. Pitfalls in the management of infantile renal neoplasia

    African Journals Online (AJOL)

    Are diagnostic possibilities transformed enough to warrant a change of approach in a setting like this? What are the 'benign' lesions that require consideration? .... diagnosis. Though accurate in the UKCCSG studies, its use as a one off diagnostic tool may have limitations as demonstrated in our case. Partial nephrectomy is ...

  15. Results of the PEP`93 intercomparison of reference cell calibrations and newer technology performance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Osterwald, C.R.; Emery, K. [National Renewable Energy Lab., Golden, CO (United States); Anevsky, S. [All-Union Research Inst. for Optophysical Measurements, Moscow (Russian Federation)] [and others

    1996-05-01

    This paper presents the results of an international intercomparison of photovoltaic (PV) performance measurements and calibrations. The intercomparison, which was organized and operated by a group of experts representing national laboratories from across the globe (i.e., the authors of this paper), was accomplished by circulating two sample sets. One set consisted of twenty silicon reference cells that would, hopefully, form the basis of an international PV reference scale. A qualification procedure applied to the calibration results gave average calibration numbers with an overall standard deviation of less than 2% for the entire set. The second set was assembled from a wide range of newer technologies that present unique problems for PV measurements. As might be expected, these results showed much larger differences among laboratories. Methods were then identified that should be used to measure such devices, along with problems to avoid.

  16. Robotic-assisted laparoscopic radical nephrectomy using the Da Vinci Si system: how to improve surgeon autonomy. Our step-by-step technique.

    Science.gov (United States)

    Davila, Hugo H; Storey, Raul E; Rose, Marc C

    2016-09-01

    Herein, we describe several steps to improve surgeon autonomy during a Left Robotic-Assisted Laparoscopic Radical Nephrectomy (RALRN), using the Da Vinci Si system. Our kidney cancer program is based on 2 community hospitals. We use the Da Vinci Si system. Access is obtained with the following trocars: Two 8 mm robotic, one 8 mm robotic, bariatric length (arm 3), 15 mm for the assistant and 12 mm for the camera. We use curved monopolar scissors in robotic arm 1, Bipolar Maryland in arm 2, Prograsp Forceps in arm 3, and we alternate throughout the surgery with EndoWrist clip appliers and the vessel sealer. Here, we described three steps and the use of 3 robotic instruments to improve surgeon autonomy. Step 1: the lower pole of the kidney was dissected and this was retracted upwards and laterally. This maneuver was performed using the 3rd robotic arm with the Prograsp Forceps. Step 2: the monopolar scissors was replaced (robotic arm 1) with the robotic EndoWrist clip applier, 10 mm Hem-o-Lok. The renal artery and vein were controlled and transected by the main surgeon. Step 3: the superior, posterolateral dissection and all bleeders were carefully coagulated by the surgeon with the EndoWrist one vessel sealer. We have now performed 15 RALRN following these steps. Our results were: blood loss 300 cc, console time 140 min, operating room time 200 min, anesthesia time 180 min, hospital stay 2.5 days, 1 incisional hernia, pathology: (13) RCC clear cell, (1) chromophobe and (1) papillary type 1. Tumor Stage: (5) T1b, (8) T2a, (2) T2b. We provide a concise, step-by-step technique for radical nephrectomy (RN) using the Da Vinci Si robotic system that may provide more autonomy to the surgeon, while maintaining surgical outcome equivalent to standard laparoscopic RN.

  17. Factors associated with admission to the intensive care unit in patients undergoing nephrectomy

    Directory of Open Access Journals (Sweden)

    L.D. Carrillo-Córdova

    2017-10-01

    Full Text Available Background: At present, there is no known risk factor analysis in patients undergoing nephrectomy secondary to lithiasis that favor their entry into the intensive care unit. There is no consensus in methods that report post-surgical complications. As a consequence, the reported incidence of complications in renal surgery ranges from 2% to 54%, regardless of the surgical approach. Methodology: A total of 58 patients with diagnosis of renal exclusion confirmed by renal scintigraphy, and lithiasis, were submitted to simple nephrectomy by a group of expert surgeons. A total of 58 patients were evaluated. Descriptive statistics were measured for the demographic variables. Inferential statistics were evaluated in quantitative variables using the Student's T test, with a p < 0.005. Chi square test was used for the qualitative variables. Results: When the multivariate analysis was carried out between the variables: age, weight, height, diabetes mellitus, systemic hypertension, smoking, abscess and transfusion, it was not possible to identify correlation between these and the development of complications or admission to the intensive care unit. However, when assessing by logistic regression the relationship between transfusing a patient and developing complications, a positive relationship was found with a p = 0.003, and an OR 13.45 CI [2.4–72]. Patients who suffered complications required a longer stay in the intensive care unit (p = 0.002. Conclusions: It was observed that patients with comorbidities such as hypertension, diabetes mellitus and anemia are more likely to require handling per unit of intensive care, even greater in those requiring transsurgical transfusion. Because there are not enough studies that relate the different risk factors that require intensive care unit management, a risk classification or transsurgical transfusion indications in these patients cannot yet be mentioned. Resumen: Antecedentes: En la

  18. Adjuvant Sunitinib for High-risk Renal Cell Carcinoma After Nephrectomy: Subgroup Analyses and Updated Overall Survival Results

    DEFF Research Database (Denmark)

    Motzer, Robert J; Ravaud, Alain; Patard, Jean-Jacques

    2018-01-01

    BACKGROUND: Adjuvant sunitinib significantly improved disease-free survival (DFS) versus placebo in patients with locoregional renal cell carcinoma (RCC) at high risk of recurrence after nephrectomy (hazard ratio [HR] 0.76, 95% confidence interval [CI] 0.59-0.98; p=0.03). OBJECTIVE: To report...... sunitinib over placebo was observed across subgroups, including: higher risk (T3, no or undetermined nodal involvement, Fuhrman grade ≥2, ECOG PS ≥1, T4 and/or nodal involvement; hazard ratio [HR] 0.74, 95% confidence interval [CI] 0.55-0.99; p=0.04), NLR ≤3 (HR 0.72, 95% CI 0.54-0.95; p=0.02), and Fuhrman...... grade 3/4 (HR 0.73, 95% CI 0.55-0.98; p=0.04). All subgroup analyses were exploratory, and no adjustments for multiplicity were made. Median OS was not reached in either arm (HR 0.92, 95% CI 0.66-1.28; p=0.6); 67 and 74 patients died in the sunitinib and placebo arms, respectively. CONCLUSIONS...

  19. Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients

    Directory of Open Access Journals (Sweden)

    Pramita Suwal

    2017-03-01

    Full Text Available Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy class I and II arches with or without modification areas were selected for the study. Group-A was treated with cast partial denture and Group-B with acrylic partial denture. Data collected during follow-up visit of 3 months, 6 months, and 1 year by evaluating retention, stability, masticatory efficiency, comfort, periodontal health of abutment. Results: Chi-square test was applied to find out differences between the groups at 95% confidence interval where p = 0.05. One year comparison shows that cast partial denture maintained retention and stability better than acrylic partial denture (p< 0.05. The masticatory efficiency was significantly compromising from 3rd month to 1 year in all acrylic partial denture groups (p< 0.05. The comfort of patient with cast partial denture was maintained better during the observation period (p< 0.05. Periodontal health of abutment was gradually deteriorated in all acrylic denture group (p

  20. Marginal adaptation of newer root canal sealers to dentin: A SEM study.

    Science.gov (United States)

    Polineni, Swapnika; Bolla, Nagesh; Mandava, Pragna; Vemuri, Sayesh; Mallela, Madhusudana; Gandham, Vijaya Madhuri

    2016-01-01

    This in vitro study evaluated and compared the marginal adaptation of three newer root canal sealers to root dentin. Thirty freshly extracted human single-rooted teeth with completely formed apices were taken. Teeth were decoronated, and root canals were instrumented. The specimens were randomly divided into three groups (n = 10) based upon the sealer used. Group 1 - teeth were obturated with epoxy resin sealer (MM-Seal). Group 2 - teeth were obturated with mineral trioxide aggregate (MTA) based sealer (MTA Fillapex), Group 3 - teeth were obturated with bioceramic sealer (EndoSequence BC sealer). Later samples were vertically sectioned using hard tissue microtome and marginal adaptation of sealers to root dentin was evaluated under coronal and apical halves using scanning electron microscopy (SEM) and marginal gap values were recorded. The data were statistically analyzed by two-way ANOVA and Tukey's multiple post hoc test. The highest marginal gap was seen in Group 2 (apical-16680.00 nm, coronal-10796 nm) and the lowest marginal gap was observed in Group 1 (apical-599.42 nm, coronal-522.72 nm). Coronal halves showed superior adaptation compared to apical halves in all the groups under SEM. Within the limitations of this study epoxy resin-based MM-Seal showed good marginal adaptation than other materials tested.

  1. Effectiveness, tolerability and practical application of the newer generation anti-obesity medications

    Directory of Open Access Journals (Sweden)

    Jeffrey S MacDaniels

    2016-03-01

    Full Text Available Objective: Comparison of the efficacy and tolerability of five newer anti-obesity medications to guide clinical decision making, examining bupropion–naltrexone combination, liraglutide, lorcaserin, orlistat, and phentermine–topiramate combination. Methods: A brief literature review and internet search for high-powered, randomized and placebo-controlled drug trials was conducted. Drug trial information was established for five currently approved anti-obesity medications. Secondarily, a statistical comparison of medications through Number Needed to Treat (NNT and Number Needed to Harm (NNH analyses were attempted as a way to provide a clinical analysis across these varied medications. Finally, a commentary about clinical application is issued for each agent accounting for typical side-effects, serious side-effects, mechanism of action and ease of use. Results: All five agents are currently approved oral medications to lower weight. The NNT range was 3–12, and NNH range was 4–17. The agent with the best NNT is phentermine–topiramate combination (NNT=3 and the agent with the best NNH is bupropion–naltrexone combination (NNH=17. Conclusion: When considering each patient’s clinical presentation, knowledge of each drug’s mechanism of action, side-effect profile, efficacy, and NNT and NNH values can help in selecting an anti-obesity medication to augment his or her weight loss efforts.

  2. Acute liver injury associated with a newer formulation of the herbal weight loss supplement Hydroxycut.

    Science.gov (United States)

    Araujo, James L; Worman, Howard J

    2015-05-06

    Despite the widespread use of herbal and dietary supplements (HDS), serious cases of hepatotoxicity have been reported. The popular herbal weight loss supplement, Hydroxycut, has previously been implicated in acute liver injury. Since its introduction, Hydroxycut has undergone successive transformations in its formulation; yet, cases of liver injury have remained an ongoing problem. We report a case of a 41-year-old Hispanic man who developed acute hepatocellular liver injury with associated nausea, vomiting, jaundice, fatigue and asterixis attributed to the use of a newer formulation of Hydroxycut, SX-7 Clean Sensory. The patient required hospitalisation and improved with supportive therapy. Despite successive transformations in its formulation, potential liver injury appears to remain an ongoing problem with Hydroxycut. Our case illustrates the importance of obtaining a thorough medication history, including HDS, regardless of new or reformulated product marketing efforts. 2015 BMJ Publishing Group Ltd.

  3. A scintillation camera technique for quantitative estimation of separate kidney function and its use before nephrectomy

    International Nuclear Information System (INIS)

    Larsson, I.; Lindstedt, E.; Ohlin, P.; Strand, S.E.; White, T.

    1975-01-01

    A scintillation camera technique was used for measuring renal uptake of [ 131 I]Hippuran 80-110 s after injection. Externally measured Hippuran uptake was markedly influenced by kidney depth, which was measured by lateral-view image after injection of [ 99 Tc]iron ascorbic acid complex or [ 197 Hg]chlormerodrine. When one kidney was nearer to the dorsal surface of the body than the other, it was necessary to correct the externally measured Hippuran uptake for kidney depth to obtain reliable information on the true partition of Hippuran between the two kidneys. In some patients the glomerular filtration rate (GFR) was measured before and after nephrectomy. Measured postoperative GFR was compared with preoperative predicted GFR, which was calculated by multiplying the preoperative Hippuran uptake of the kidney to be left in situ, as a fraction of the preoperative Hippuran uptake of both kidneys, by the measured preoperative GFR. The measured postoperative GFR was usually moderately higher than the preoperatively predicted GFR. The difference could be explained by a postoperative compensatory increase in function of the remaining kidney. Thus, the present method offers a possibility of estimating separate kidney function without arterial or ureteric catheterization. (auth)

  4. Compensatory Structural and Functional Adaptation after Radical Nephrectomy for Renal Cell Carcinoma According to Preoperative Stage of Chronic Kidney Disease.

    Science.gov (United States)

    Choi, Don Kyoung; Jung, Se Bin; Park, Bong Hee; Jeong, Byong Chang; Seo, Seong Il; Jeon, Seong Soo; Lee, Hyun Moo; Choi, Han-Yong; Jeon, Hwang Gyun

    2015-10-01

    We investigated structural hypertrophy and functional hyperfiltration as compensatory adaptations after radical nephrectomy in patients with renal cell carcinoma according to the preoperative chronic kidney disease stage. We retrospectively identified 543 patients who underwent radical nephrectomy for renal cell carcinoma between 1997 and 2012. Patients were classified according to preoperative glomerular filtration rate as no chronic kidney disease--glomerular filtration rate 90 ml/minute/1.73 m(2) or greater (230, 42.4%), chronic kidney disease stage II--glomerular filtration rate 60 to less than 90 ml/minute/1.73 m(2) (227, 41.8%) and chronic kidney disease stage III--glomerular filtration rate 30 to less than 60 ml/minute/1.73 m(2) (86, 15.8%). Computerized tomography performed within 2 months before surgery and 1 year after surgery was used to assess functional renal volume for measuring the degree of hypertrophy of the remnant kidney, and the preoperative and postoperative glomerular filtration rate per unit volume of functional renal volume was used to calculate the degree of hyperfiltration. Among all patients (mean age 56.0 years) mean preoperative glomerular filtration rate, functional renal volume and glomerular filtration rate/functional renal volume were 83.2 ml/minute/1.73 m(2), 340.6 cm(3) and 0.25 ml/minute/1.73 m(2)/cm(3), respectively. The percent reduction in glomerular filtration rate was statistically significant according to chronic kidney disease stage (no chronic kidney disease 31.2% vs stage II 26.5% vs stage III 12.8%, p kidney was not statistically significant (no chronic kidney disease 18.5% vs stage II 17.3% vs stage III 16.5%, p=0.250). The change in glomerular filtration rate/functional renal volume was statistically significant (no chronic kidney disease 18.5% vs stage II 20.1% vs stage III 45.9%, p chronic kidney disease stage (p <0.001). Patients with a lower preoperative glomerular filtration rate had a smaller reduction in

  5. Prognostic Significance of Blood Type A in Patients with Renal Cell Carcinoma.

    Science.gov (United States)

    Ko, Kyungtae; Park, Young Hyun; Jeong, Chang Wook; Ku, Ja Hyeon; Kim, Hyeon Hoe; Kwak, Cheol

    2016-08-25

    In this study, we evaluated the prognostic significance of the ABO blood type in patients with renal cell carcinoma (RCC) who had undergone partial or radical nephrectomy. Information on the ABO blood type was obtained from 1750 patients with RCC. A total of 1243 men and 507 women (mean age, 55.41 ± 12.43 years) with RCC who had undergone partial or radical nephrectomy were enrolled in this study. The median follow-up duration was 35.0 months (interquartile range [IQR], 16.0-67.0). During the follow-up period, 271 patients experienced RCC recurrence, and 137 patients died from RCC. Type A was the most common blood type (568, 32.5%), followed by type O (525, 30.0%), type B (464, 26.5%), and type AB (193, 11.0%). Generally, blood type was not associated with any clinicopathological factors. Unlike blood type O, the multivariate analysis of progression-free survival (PFS) showed that blood type non-O (A, B, and AB) was an independent prognostic factor for a worse outcome (95% confidence interval [CI]: 1.24- 2.37, hazard ratio [HR] = 1.71, P = .001; 95% CI: 1.08-2.13, HR = 1.51, P = .016; 95% CI: 1.03-2.43, HR = 1.58, P = .037, respectively). Cancer-specific survival (CSS) analysis showed that blood type A was an independent factor associated with a worse prognosis for CSS (95% CI: 1.05-2.64, HR 1.66, P = .031, respectively). The ABO blood type is significantly associated with PFS and CSS in patients with RCC following partial or radical nephrectomy. Blood type non-O (A, B, and AB) is an independent prognostic factor for a worse PFS outcome, and blood type A is an independent factor associated with a worse CSS prognosis. .

  6. Antiandrogenic and antimineralocorticoid health benefits of COC containing newer progestogens: dienogest and drospirenone.

    Science.gov (United States)

    Regidor, Pedro-Antonio; Schindler, Adolf E

    2017-10-10

    Data have demonstrated that COCs, besides offering a satisfactory and safe contraception, offer a variety of non-contraceptive health benefits and therapeutic positive aspects. Many prescribes and users, however, do not realize these positive aspects especially the non-contraceptive health benefits. While the contraceptive use is the primary indication for COC use for most women, these users should be advised in regard of the non-contraceptive benefits when contraception is discussed and prescribed. Using COCs specifically for non-contraceptive indications is an off-label use in many clinical situations (only some exceptions as e.g. acne vulgaris in some countries are allowed clinical entities for the use of these drugs). Therefore, appropriate discussions with the patient regarding this fact should performed and documented by the prescribing physicians. Independent of the off-label situation, COCs containing the newer progestogens dienogest and drospirenone with their antiandrogenic and antimineralocorticoid health benefits play an important role in the management of many diseases and their use should therefore be considered by clinician's. This review will focus on the effects of these COCs on the endometrium, the skin, the fat tissue and the premenstrual syndrome.

  7. Ultrastructural changes and nestin expression accompanying compensatory renal growth after unilateral nephrectomy in adult rats

    Directory of Open Access Journals (Sweden)

    Eladl MA

    2017-02-01

    Full Text Available Mohamed Ahmed Eladl,1,2 Wael M Elsaed,2,3 Hoda Atef,4 Mohamed El-Sherbiny2 1Department of Basic Medical Sciences, University of Sharjah, Sharjah, United Arab Emirates; 2Anatomy and Embryology Department, Faculty of Medicine, Mansoura University, Mansoura, Egypt; 3Anatomy and Embryology Department, Faculty of Medicine, Taibah University, Madinah, Saudi Arabia; 4Department of Histology, University of Mansoura, Mansoura, Egypt Background: Several renal disorders affect the glomerular podocytes. Compensatory structural and functional changes have been observed in animals that have undergone unilateral renal ablation. These changes occur as a pliant response to quench the increased functional demand to maintain homeostasis of fluid and solutes. Nestin is an intermediate filament protein present in the glomerular podocytes of the adult kidney and is linked with the maintenance of its foot process structure. Structural changes in the podocytes ultimately restructure the filtration barrier. Very few studies related to the ultrastructural and histopathologic changes of the podocytes are documented. The present study aimed to assess the histopathologic changes at the ultrastructural level in the adapted kidney at different time intervals following unilateral renal ablation in adult rats and its relation with nestin.Methods: Forty-eight rats were divided into four groups (n=12 in each group. The animals of Group A were control naïve rats, while the group B, group C and group D animals underwent left unilateral nephrectomy and the remaining right kidney was removed on days 10, 20 and 30, respectively. Each group included four sham-operated rats, which were sacrificed at the same time as the naïve rats. Each nephrectomized sample was weighed and its sections were subjected to hematoxylin and eosin examination, transmission electron microscopic study as well as immunostaining using the intermediate filament protein nestin.Results: No difference was found

  8. Complications and renal functional deterioration in patients with co ...

    African Journals Online (AJOL)

    E. Sharma

    2016-07-26

    Jul 26, 2016 ... (CCS) [7] with scores varying from 2 to 7. Eleven patients had CCS of 2, twelve patients had CCS of 3, nineteen patients had CCS of. 4, eighteen patients had CCS of 5, seven patients had CCS of 6 and one patient had CCS of 7 (Chart 1). Partial nephrectomy was done laparoscopically, hilar clamping.

  9. Comparative field evaluation of some newer versus conventional insecticides for the control of aphids (homoptera: aphididae) on oilseed rape (brassica napus l.)

    International Nuclear Information System (INIS)

    Sarwar, M.; Ahmad, N.; Bux, M.; Nasrullah, A.; Tofique, M.

    2011-01-01

    This study was designed to evaluate the effects of new insecticides like, Imidacloprid (Confidor 200 EC), Thiomethoxam (Actara 25 WG) and Acetamiprid (Megamos 20 SL) belonging to Nitroguanidine group along with conventional insecticides such as, Chlorpyrifos (Lorsban 40 EC) and Dimethoate (Systoate 40 EC) belonging to Organophosphate group against aphids' population on oilseed rape (Brassica napus L.). A perusal of data, based on the overall performance of the test compounds, reflected that newer insecticides were superior in reducing the population of aphids and yield enhancement as compared to conventional insecticides. The best results were achieved with the application of Imidacloprid by recording the lowest number of aphids (2.2 per plant) than obtained with Thiomethoxam and Acetamiprid (3.22 and 4.66, respectively). Other insecticides, viz., Chlorpyrifos and Dimethoate were also found to be effective in maintaining the aphids' population at lower levels per plant (16.2 and 17.5, respectively) over untreated control (227.7). Imidacloprid was responsible for increasing the grain yield to 3722.85 Kg per Hectare, approached by Thiomethoxam, Acetamiprid, Chlorpyrifos and Dimethoate as against unsprayed control (2980.0, 2542.85, 1542.85, 540.0 and 604.85 Kg per Hectare, respectively). Study indicated that selective use of newer insecticides would seem a reasonable strategy in aphids controlling and integration of such chemicals in insects' management package could help to reduce pest densities. (author)

  10. Selection criteria for the clinical use of the newer antiepileptic drugs.

    NARCIS (Netherlands)

    Deckers, C.L.P.; Knoester, P.D.; Haan, G.J. de; Keyser, A.J.M.; Renier, W.O.; Hekster, Y.A.

    2003-01-01

    In recent years, several new antiepileptic drugs (AEDs) have been licensed: felbamate, gabapentin, lamotrigine, levetiracetam, oxcarbazepine, tiagabine, topiramate, vigabatrin and zonisamide. These drugs have proven efficacy as add-on therapy in patients with difficult-to-treat partial epilepsy, as

  11. Effect of tocopherol on atherosclerosis, vascular function, and inflammation in apolipoprotein E knockout mice with subtotal nephrectomy.

    Science.gov (United States)

    Shing, Cecilia M; Fassett, Robert G; Peake, Jonathan M; Coombes, Jeff S

    2014-12-01

    Inflammation and endothelial dysfunction contribute to cardiovascular disease, prevalent in chronic kidney disease (CKD). Antioxidant supplements such as tocopherols may reduce inflammation and atherosclerosis. This study aimed to investigate the effect of tocopherol supplementation on vascular function, aortic plaque formation, and inflammation in apolipoprotein E(-/-) mice with 5/6 nephrectomy as a model of combined cardiovascular and kidney disease. Nephrectomized mice were assigned to a normal chow diet group (normal chow), a group receiving 1000 mg/kg diet of α-tocopherol supplementation or a group receiving 1000 mg/kg diet mixed-tocopherol (60% γ-tocopherol). Following 12 weeks, in vitro aortic endothelial-independent relaxation was enhanced with both α-tocopherol and mixed-tocopherol (P tocopherol enhanced aortic contraction at noradrenaline concentrations of 3 × 10(-7) M to 3 × 10(-5) M (P tocopherol reduced systemic concentrations of IL-6 (P tocopherol also reduced MCP-1 (P tocopherol supplementation when compared to normal chow (P Tocopherol supplementation favorably influenced vascular function and cytokine profile, while it was also effective in reducing atherosclerosis in the apolipoprotein E(-/-) mouse with CKD. © 2014 John Wiley & Sons Ltd.

  12. The efficacy and safety of newer anticonvulsants in patients with dementia.

    Science.gov (United States)

    Dolder, Christian R; Nealy, Kimberly L

    2012-08-01

    Anticonvulsants are a class of medications that have received considerable interest as possible treatments in patients with behavioural disturbances in dementia. The role of these medications for such a use remains controversial. The current paper reviews the published evidence surrounding the safety and efficacy (i.e. as a behavioural and cognitive treatment) of newer anticonvulsants in patients with dementia. A MEDLINE, International Pharmaceutical Abstracts, PsycINFO and clinicaltrials.gov search through to December 2011 was conducted for anticonvulsants that have received regulatory approval since 1996. Studies reporting behavioural or cognitive outcomes in patients with dementia were included. Nine trials involving only four medications met selection criteria and were included: levetiracetam (n = 4), oxcarbazepine (n = 1), topiramate (n = 2) and zonisamide (n = 2). Levetiracetam may have a role in the treatment of behavioural symptoms in dementia but study limitations substantially hinder the strength of such a recommendation. Oxcarbazepine and topiramate, based on limited data, do not appear to be effective treatments of behavioural symptoms in dementia. A lack of trials do not allow for conclusions to be made regarding zonisamide. From a cognitive standpoint, levetiracetam was the anticonvulsant most examined in patients with dementia, it appears to have less deleterious effects than some anticonvulsants. Limited data are available on the safety of these medications in elderly patients; however, studies completed thus far have demonstrated some adverse events that are more common or problematic with the use of these drugs in this patient population (i.e. somnolence, dizziness, hyponatraemia, weight loss).

  13. A Rare Case of Metastasis to the Thyroid Gland from Renal Clear Cell Carcinoma 11 Years after Nephrectomy and Concurrent Primary Esophageal Carcinoma

    Directory of Open Access Journals (Sweden)

    Mohammad Saud Khan

    2018-01-01

    Full Text Available Renal cell carcinoma is known to cause metastasis to unusual sites, which can be both synchronous or metachronous. Thyroid gland is a rare site for metastasis, but when it occurs, renal cell carcinoma is the most common primary neoplasm. We report the case of a 81-year-old female patient who had a significant medical history of right clear cell renal carcinoma with adrenal metastasis. She underwent right radical nephrectomy and adrenalectomy followed by radiofrequency ablation of left adrenal metastasis and systemic chemotherapy with sunitinib. Eleven years later, she presented with dysphagia and was found to have distal esophageal adenocarcinoma. On imaging, there was incidental detection of a left renal mass lesion and a right thyroid nodule, which on histopathology and immunohistochemistry were confirmed to be clear cell carcinoma of renal origin.

  14. Recurrent Partial Words

    Directory of Open Access Journals (Sweden)

    Francine Blanchet-Sadri

    2011-08-01

    Full Text Available Partial words are sequences over a finite alphabet that may contain wildcard symbols, called holes, which match or are compatible with all letters; partial words without holes are said to be full words (or simply words. Given an infinite partial word w, the number of distinct full words over the alphabet that are compatible with factors of w of length n, called subwords of w, refers to a measure of complexity of infinite partial words so-called subword complexity. This measure is of particular interest because we can construct partial words with subword complexities not achievable by full words. In this paper, we consider the notion of recurrence over infinite partial words, that is, we study whether all of the finite subwords of a given infinite partial word appear infinitely often, and we establish connections between subword complexity and recurrence in this more general framework.

  15. Robotic Laparoendoscopic Single-site Retroperitioneal Renal Surgery: Initial Investigation of a Purpose-built Single-port Surgical System.

    Science.gov (United States)

    Maurice, Matthew J; Ramirez, Daniel; Kaouk, Jihad H

    2017-04-01

    Robotic single-site retroperitoneal renal surgery has the potential to minimize the morbidity of standard transperitoneal and multiport approaches. Traditionally, technological limitations of non-purpose-built robotic platforms have hindered the application of this approach. To assess the feasibility of retroperitoneal renal surgery using a new purpose-built robotic single-port surgical system. This was a preclinical study using three male cadavers to assess the feasibility of the da Vinci SP1098 surgical system for robotic laparoendoscopic single-site (R-LESS) retroperitoneal renal surgery. We used the SP1098 to perform retroperitoneal R-LESS radical nephrectomy (n=1) and bilateral partial nephrectomy (n=4) on the anterior and posterior surfaces of the kidney. Improvements unique to this system include enhanced optics and intelligent instrument arm control. Access was obtained 2cm anterior and inferior to the tip of the 12th rib using a novel 2.5-cm robotic single-port system that accommodates three double-jointed articulating robotic instruments, an articulating camera, and an assistant port. The primary outcome was the technical feasibility of the procedures, as measured by the need for conversion to standard techniques, intraoperative complications, and operative times. All cases were completed without the need for conversion. There were no intraoperative complications. The operative time was 100min for radical nephrectomy, and the mean operative time was 91.8±18.5min for partial nephrectomy. Limitations include the preclinical model, the small sample size, and the lack of a control group. Single-site retroperitoneal renal surgery is feasible using the latest-generation SP1098 robotic platform. While the potential of the SP1098 appears promising, further study is needed for clinical evaluation of this investigational technology. In an experimental model, we used a new robotic system to successfully perform major surgery on the kidney through a single small

  16. A comparison of numerical solutions of partial differential equations with probabilistic and possibilistic parameters for the quantification of uncertainty in subsurface solute transport.

    Science.gov (United States)

    Zhang, Kejiang; Achari, Gopal; Li, Hua

    2009-11-03

    Traditionally, uncertainty in parameters are represented as probabilistic distributions and incorporated into groundwater flow and contaminant transport models. With the advent of newer uncertainty theories, it is now understood that stochastic methods cannot properly represent non random uncertainties. In the groundwater flow and contaminant transport equations, uncertainty in some parameters may be random, whereas those of others may be non random. The objective of this paper is to develop a fuzzy-stochastic partial differential equation (FSPDE) model to simulate conditions where both random and non random uncertainties are involved in groundwater flow and solute transport. Three potential solution techniques namely, (a) transforming a probability distribution to a possibility distribution (Method I) then a FSPDE becomes a fuzzy partial differential equation (FPDE), (b) transforming a possibility distribution to a probability distribution (Method II) and then a FSPDE becomes a stochastic partial differential equation (SPDE), and (c) the combination of Monte Carlo methods and FPDE solution techniques (Method III) are proposed and compared. The effects of these three methods on the predictive results are investigated by using two case studies. The results show that the predictions obtained from Method II is a specific case of that got from Method I. When an exact probabilistic result is needed, Method II is suggested. As the loss or gain of information during a probability-possibility (or vice versa) transformation cannot be quantified, their influences on the predictive results is not known. Thus, Method III should probably be preferred for risk assessments.

  17. Computed tomography findings of pancreatic metastases from renal cell carcinoma

    International Nuclear Information System (INIS)

    Prando, Adilson

    2008-01-01

    Objective: To present computed tomography findings observed in four patients submitted to radical nephrectomy for renal cell carcinoma who developed pancreatic metastases afterwards. Materials and methods: The four patients underwent radical nephrectomy for stage Tz1 (n=2) and stage T3a (n=2) renal cell carcinoma. The mean interval between nephrectomy and detection of pancreatic metastases was eight years. Two asymptomatic patients presented with solitary pancreatic metastases (confined to the pancreas). Two symptomatic patients presented with single and multiple pancreatic metastases, both with tumor recurrence in the contralateral kidney. Results: Computed tomography studies demonstrated pancreatic metastases as solitary (n=2), single (n=1) or multiple (n=1) hypervascular lesions. Partial pancreatectomy was performed in two patients with solitary pancreatic metastases and both are free of disease at four and two years after surgery. Conclusion: Pancreatic metastases from renal cell carcinoma are rare and can occur many years after the primary tumor presentation. Multiple pancreatic metastases and pancreatic metastases associated with tumor recurrence in the contralateral kidney are uncommon. Usually, on computed tomography images pancreatic metastases are visualized as solitary hypervascular lesions, simulating isletcell tumors. Surgical management should be considered for patients with solitary pancreatic lesions. (author)

  18. Computed tomography findings of pancreatic metastases from renal cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Prando, Adilson [Hospital Vera Cruz, Campinas, SP (Brazil). Dept. of Radiology and Imaging Diagnosis]. E-mail: adilson.prando@gmail.com

    2008-07-15

    Objective: To present computed tomography findings observed in four patients submitted to radical nephrectomy for renal cell carcinoma who developed pancreatic metastases afterwards. Materials and methods: The four patients underwent radical nephrectomy for stage Tz1 (n=2) and stage T3a (n=2) renal cell carcinoma. The mean interval between nephrectomy and detection of pancreatic metastases was eight years. Two asymptomatic patients presented with solitary pancreatic metastases (confined to the pancreas). Two symptomatic patients presented with single and multiple pancreatic metastases, both with tumor recurrence in the contralateral kidney. Results: Computed tomography studies demonstrated pancreatic metastases as solitary (n=2), single (n=1) or multiple (n=1) hypervascular lesions. Partial pancreatectomy was performed in two patients with solitary pancreatic metastases and both are free of disease at four and two years after surgery. Conclusion: Pancreatic metastases from renal cell carcinoma are rare and can occur many years after the primary tumor presentation. Multiple pancreatic metastases and pancreatic metastases associated with tumor recurrence in the contralateral kidney are uncommon. Usually, on computed tomography images pancreatic metastases are visualized as solitary hypervascular lesions, simulating isletcell tumors. Surgical management should be considered for patients with solitary pancreatic lesions. (author)

  19. Aripiprazole, A Drug that Displays Partial Agonism and Functional Selectivity.

    Science.gov (United States)

    Tuplin, Erin W; Holahan, Matthew R

    2017-11-14

    The treatment of schizophrenia is challenging due to the wide range of symptoms (positive, negative, cognitive) associated with the disease. Typical antipsychotics that antagonize D2 receptors are effective in treating positive symptoms, but extrapyramidal side-effects (EPS) are a common occurrence. Atypical antipsychotics targeting 5-HT2A and D2 receptors are more effective at treating cognitive and negative symptoms compared to typical antipsychotics, but these drugs also result in side-effects such as metabolic syndromes. To identify evidence in the literature that elucidates the pharmacological profile of aripiprazole.s. We searched PubMed for peer reviewed articles on aripiprazole and its clinical efficacy, side-effects, pharmacology, and effects in animal models of schizophrenia symptoms. Aripiprazole is a newer atypical antipsychotic that displays a unique pharmacological profile, including partial D2 agonism and functionally selective properties. Aripiprazole is effective at treating the positive symptoms of schizophrenia and has the potential to treat negative and cognitive symptoms at least as well as other atypical antipsychotics. The drug has a favorable side-effect profile and has a low propensity to result in EPS or metabolic syndromes. Animal models of schizophrenia have been used to determine the efficacy of aripiprazole in symptom management. In these instances, aripiprazole resulted in the reversal of deficits in extinction, pre-pulse inhibition, and social withdrawal. Because aripiprazole requires a greater than 90% occupancy rate at D2 receptors to be clinically active and does not produce EPS, this suggests a functionally selective effect on intracellular signaling pathways. A combination of factors such as dopamine system stabilization via partial agonism, functional selectivity at D2 receptors, and serotonin-dopamine system interaction may contribute to the ability of aripiprazole to successfully manage schizophrenia symptoms. This review

  20. Partial differential equation techniques for analysing animal movement: A comparison of different methods.

    Science.gov (United States)

    Wang, Yi-Shan; Potts, Jonathan R

    2017-03-07

    Recent advances in animal tracking have allowed us to uncover the drivers of movement in unprecedented detail. This has enabled modellers to construct ever more realistic models of animal movement, which aid in uncovering detailed patterns of space use in animal populations. Partial differential equations (PDEs) provide a popular tool for mathematically analysing such models. However, their construction often relies on simplifying assumptions which may greatly affect the model outcomes. Here, we analyse the effect of various PDE approximations on the analysis of some simple movement models, including a biased random walk, central-place foraging processes and movement in heterogeneous landscapes. Perhaps the most commonly-used PDE method dates back to a seminal paper of Patlak from 1953. However, our results show that this can be a very poor approximation in even quite simple models. On the other hand, more recent methods, based on transport equation formalisms, can provide more accurate results, as long as the kernel describing the animal's movement is sufficiently smooth. When the movement kernel is not smooth, we show that both the older and newer methods can lead to quantitatively misleading results. Our detailed analysis will aid future researchers in the appropriate choice of PDE approximation for analysing models of animal movement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Partial tooth gear bearings

    Science.gov (United States)

    Vranish, John M. (Inventor)

    2010-01-01

    A partial gear bearing including an upper half, comprising peak partial teeth, and a lower, or bottom, half, comprising valley partial teeth. The upper half also has an integrated roller section between each of the peak partial teeth with a radius equal to the gear pitch radius of the radially outwardly extending peak partial teeth. Conversely, the lower half has an integrated roller section between each of the valley half teeth with a radius also equal to the gear pitch radius of the peak partial teeth. The valley partial teeth extend radially inwardly from its roller section. The peak and valley partial teeth are exactly out of phase with each other, as are the roller sections of the upper and lower halves. Essentially, the end roller bearing of the typical gear bearing has been integrated into the normal gear tooth pattern.

  2. Comments on the Eslicarbazepine Acetate Section of the Article ‘Therapeutic Drug Monitoring of the Newer Anti-Epilepsy Medications’

    Directory of Open Access Journals (Sweden)

    Patricio Soares-da-Silva

    2010-12-01

    Full Text Available The recent review of Matthew D. Krasowski on ‘Therapeutic Drug Monitoring of the Newer Anti-Epilepsy Medications’ is a useful foundation of comparative interpretations on our current knowledge about therapeutic drug monitoring. Within the review, the statement that therapeutic drug monitoring has a minimal role in the therapeutic use of eslicarbazepine acetate due to its relatively predictable pharmacokinetics reflects the existing body of evidence although some information such as eslicarbazepine acetate’s chemical structure, proportions of its metabolites, their pharmacokinetics and chiral method of plasma level measurement need to be revised. These critical characteristics differentiate the novel compound from former dibenzazepines such as carbamazepine and oxcarbazepine in its clinical effects and needs for therapeutic drug monitoring.

  3. CPDES2: A preconditioned conjugate gradient solver for linear asymmetric matrix equations arising from coupled partial differential equations in two dimensions

    Science.gov (United States)

    Anderson, D. V.; Koniges, A. E.; Shumaker, D. E.

    1988-11-01

    Many physical problems require the solution of coupled partial differential equations on two-dimensional domains. When the time scales of interest dictate an implicit discretization of the equations a rather complicated global matrix system needs solution. The exact form of the matrix depends on the choice of spatial grids and on the finite element or finite difference approximations employed. CPDES2 allows each spatial operator to have 5 or 9 point stencils and allows for general couplings between all of the component PDE's and it automatically generates the matrix structures needed to perform the algorithm. The resulting sparse matrix equation is solved by either the preconditioned conjugate gradient (CG) method or by the preconditioned biconjugate gradient (BCG) algorithm. An arbitrary number of component equations are permitted only limited by available memory. In the sub-band representation used, we generate an algorithm that is written compactly in terms of indirect indices which is vectorizable on some of the newer scientific computers.

  4. CPDES3: A preconditioned conjugate gradient solver for linear asymmetric matrix equations arising from coupled partial differential equations in three dimensions

    Science.gov (United States)

    Anderson, D. V.; Koniges, A. E.; Shumaker, D. E.

    1988-11-01

    Many physical problems require the solution of coupled partial differential equations on three-dimensional domains. When the time scales of interest dictate an implicit discretization of the equations a rather complicated global matrix system needs solution. The exact form of the matrix depends on the choice of spatial grids and on the finite element or finite difference approximations employed. CPDES3 allows each spatial operator to have 7, 15, 19, or 27 point stencils and allows for general couplings between all of the component PDE's and it automatically generates the matrix structures needed to perform the algorithm. The resulting sparse matrix equation is solved by either the preconditioned conjugate gradient (CG) method or by the preconditioned biconjugate gradient (BCG) algorithm. An arbitrary number of component equations are permitted only limited by available memory. In the sub-band representation used, we generate an algorithm that is written compactly in terms of indirect induces which is vectorizable on some of the newer scientific computers.

  5. Comparison of newer-generation drug-eluting with bare-metal stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFORTABLE-AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) trials.

    Science.gov (United States)

    Sabaté, Manel; Räber, Lorenz; Heg, Dik; Brugaletta, Salvatore; Kelbaek, Henning; Cequier, Angel; Ostojic, Miodrag; Iñiguez, Andrés; Tüller, David; Serra, Antonio; Baumbach, Andreas; von Birgelen, Clemens; Hernandez-Antolin, Rosana; Roffi, Marco; Mainar, Vicente; Valgimigli, Marco; Serruys, Patrick W; Jüni, Peter; Windecker, Stephan

    2014-01-01

    This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up. Copyright © 2014 American

  6. Can a Modified Bosniak Classification System Risk Stratify Pediatric Cystic Renal Masses?

    Science.gov (United States)

    Saltzman, Amanda F; Carrasco, Alonso; Colvin, Alexandra N; Meyers, Mariana L; Cost, Nicholas G

    2018-03-20

    We characterize and apply the modified Bosniak classification system to a cohort of children with cystic renal lesions and known surgical pathology. We identified all patients at our institution with cystic renal masses who also underwent surgery for these lesions. Patients without available preoperative imaging or pathology were excluded. All radiological imaging was independently reviewed by a pediatric radiologist blinded to pathological findings. Imaging characteristics (size, border, septations, calcifications, solid components, vascularity) were recorded from the most recent preoperative ultrasounds and computerized tomograms. The modified Bosniak classification system was applied to these scans and then correlated with final pathology. A total of 22 patients met study criteria. Median age at surgery was 6.1 years (range 11 months to 16.8 years). Of the patients 12 (54.5%) underwent open nephrectomy, 6 (27.3%) open partial nephrectomy, 2 (9.1%) laparoscopic cyst decortication, 1 (4.5%) open renal biopsy and 1 (4.5%) laparoscopic partial nephrectomy. Final pathology was benign in 9 cases (41%), intermediate in 6 (27%) and malignant in 7 (32%). All malignant lesions were modified Bosniak class 4, all intermediate lesions were modified class 3 or 4 and 8 of 9 benign lesions (89%) were modified class 1 or 2. Cystic renal lesions in children with a modified Bosniak class of 1 or 2 were most often benign, while class 3 or 4 lesions warranted surgical excision since more than 90% of masses harbored intermediate or malignant pathology. The modified Bosniak classification system appears to allow for a reasonable clinical risk stratification of pediatric cystic renal masses. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. A difficult decision: what should we do when malignant tumours are diagnosed in patients supported by left ventricular assist devices?

    Science.gov (United States)

    Smail, Hassiba; Pfister, Christian; Baste, Jean-Marc; Nafeh-Bizet, Catherine; Gay, Arnaud; Barbay, Virginie; Bessou, Jean-Paul; Peillon, Christophe; Litzler, Pierre-Yves

    2015-09-01

    Left ventricular assist devices (LVADs) are used as a bridge to heart transplantation. During the preimplantation or pretransplantation screening, malignant tumours can be discovered. Owing to the lack of guidelines, the management is difficult. We describe our perioperative approach and the patients' outcomes. Between 2006 and 2014, 55 patients underwent implantation of HeartMate II LVAD. Five were diagnosed with malignant tumours: 2 renal, 2 lung and 1 breast tumours. The renal tumours were diagnosed during the preimplantation screening. An LVAD was implanted in both followed by partial nephrectomies 8 and 9 months later. The lung cancers were diagnosed after device implantation, a left pulmonary segmentectomy and a right upper sleeve lobectomy were performed. The breast cancer was diagnosed few months after support and a tumourectomy with lymphadenectomy was performed. Tumour resection was performed successfully in all patients. Prior to surgery haemostasis, device and heart function were evaluated. During surgery, haemodynamics and anticoagulation were monitored. Reoperations were necessary to evacuate haemothorax after lobectomy and an abdominal haematoma post-nephrectomy. After discussion with oncologists, 3 patients were relisted for heart transplantation. Two were successfully transplanted 2 and 3 years after partial nephrectomy with an actual survival of 56 and 59 months after the cancer diagnosis. The follow-up revealed no cancer recurrences. Malignant tumours during support with LVAD can be successfully resected. A multidisciplinary evaluation in these high-risk patients is mandatory. After careful evaluation, regaining the patient's heart transplant candidacy is possible. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. Economics of long distance transmission, storage and distribution of heat from nuclear plants with existing and newer techniques

    International Nuclear Information System (INIS)

    Margen, Peter

    1977-01-01

    Nuclear plants can provide heat for district heating in mainly two ways. Central nuclear power plants sufficiently large to be economic as electricity producers could instead be designed for heat extraction at temperatures useful for district heating. The second promising way is to design simple low temperature reactors, so simple and safe that near urban location becomes feasible. The manner of transport distribution and storage of heat is discussed in this paper which are very important especially in the cost calculations. The economic objectives can often be attained already with conventional technigues even when transport distances are large. But newer techniques of transport promise to make even cities at greater distances from major nuclear power plants economically connectible whilst new techniques for small distribution pipes help to extend the economic distribution area to the less dense one-family house districts. (M.S.)

  9. Bilateral native nephrectomy to reduce oxalate stores in children at the time of combined liver-kidney transplantation for primary hyperoxaluria type 1.

    Science.gov (United States)

    Lee, Eliza; Ramos-Gonzalez, Gabriel; Rodig, Nancy; Elisofon, Scott; Vakili, Khashayar; Kim, Heung Bae

    2018-05-01

    Primary hyperoxaluria type-1 (PH-1) is a rare genetic disorder in which normal hepatic metabolism of glyoxylate is disrupted resulting in diffuse oxalate deposition and end-stage renal disease (ESRD). While most centers agree that combined liver-kidney transplant (CLKT) is the appropriate treatment for PH-1, perioperative strategies for minimizing recurrent oxalate-related injury to the transplanted kidney remain unclear. We present our management of children with PH-1 and ESRD on hemodialysis (HD) who underwent CLKT at our institution from 2005 to 2015. On chart review, three patients (2 girls, 1 boy) met study criteria. Two patients received deceased-donor split-liver grafts, while one patient received a whole liver graft. All patients underwent bilateral native nephrectomy at transplant to minimize the total body oxalate load. Median preoperative serum oxalate was 72 μmol/L (range 17.8-100). All patients received HD postoperatively until predialysis serum oxalate levels fell stores and may mitigate damage to the renal allograft.

  10. Contemporary, age-based trends in the incidence and management of patients with early-stage kidney cancer.

    Science.gov (United States)

    Tan, Hung-Jui; Filson, Christopher P; Litwin, Mark S

    2015-01-01

    Although kidney cancer incidence and nephrectomy rates have risen in tandem, clinical advances have generated new uncertainty regarding the optimal management of patients with small renal tumors, especially the elderly. To clarify existing practice patterns, we assessed contemporary trends in the incidence and management of patients with early-stage kidney cancer. Using Surveillance, Epidemiology, and End Results data, we identified adult patients diagnosed with T1aN0M0 kidney cancer from 2000 to 2010. We determined age-adjusted and age-specific incidence and management rates (i.e., nonoperative, ablation, partial nephrectomy [PN], and radical nephrectomy) per 100,000 adults and determined the average annual percent change (AAPC). Finally, we compared management groups using multinomial logistic regression accounting for patient characteristics, cancer information, and county-level measures for health. From 2000 to 2010, we identified 41,645 adults diagnosed with T1aN0M0 kidney cancer. Overall incidence increased from 3.7 to 7.0 per 100,000 adults (AAPC = 7.0%, Pmanagement and ablation approached nephrectomy rates for those aged 75 to 84 years and became the predominant strategy for patients older than 84 years. Adjusting for clinical, oncological, and environmental factors, older patients less frequently underwent PN and more often received ablative or nonoperative management (P<0.001). As the incidence of early-stage kidney cancer rises, patients are increasingly treated with nonoperative and nephron-sparing strategies, especially among the most elderly. The broader array of treatment options suggests opportunities to better personalize kidney cancer care for seniors. Published by Elsevier Inc.

  11. Experts' understanding of partial derivatives using the Partial Derivative Machine

    OpenAIRE

    Roundy, David; Dorko, Allison; Dray, Tevian; Manogue, Corinne A.; Weber, Eric

    2014-01-01

    Partial derivatives are used in a variety of different ways within physics. Most notably, thermodynamics uses partial derivatives in ways that students often find confusing. As part of a collaboration with mathematics faculty, we are at the beginning of a study of the teaching of partial derivatives, a goal of better aligning the teaching of multivariable calculus with the needs of students in STEM disciplines. As a part of this project, we have performed a pilot study of expert understanding...

  12. Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Type-directed partial evaluation uses a normalization function to achieve partial evaluation. These lecture notes review its background, foundations, practice, and applications. Of specific interest is the modular technique of offline and online type-directed partial evaluation in Standard ML...

  13. Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Type-directed partial evaluation uses a normalization function to achieve partial evaluation. These lecture notes review its background, foundations, practice, and applications. Of specific interest is the modular technique of offline and online type-directed partial evaluation in Standard ML of ...

  14. Role of R.E.N.A.L. Nephrometry Score in Laparoscopic Partial Nephrectomy

    Directory of Open Access Journals (Sweden)

    Hai-Jiang Zhou

    2017-01-01

    Conclusions: The RNS is a valuable tool for evaluating the complexity of renal tumor anatomy. It can aid surgeons in preoperative decision-making concerning management therapy. Future multicenter, large sample size studies are warranted for evaluating its predicting performance of perioperative outcomes.

  15. Initial Clinical Experience With Surgical Technique of Robot-assisted Transperitoneal Laparoscopic Partial Nephrectomy

    Directory of Open Access Journals (Sweden)

    Cheng-Kuang Yang

    2009-12-01

    Conclusion: Robot-assisted LPN is feasible and may be a viable alternative to open or LPN in selected patients with small exophytic renal tumors. Compared with standard LPN, the robotic assisted LPN approach with precise renal reconstruction under a safe warm ischemia time is feasible and can be easily adopted by those with experience in robot-assisted surgery.

  16. Standardized analysis of laparoscopic and robotic-assisted partial nephrectomy complications with Clavien classification

    Directory of Open Access Journals (Sweden)

    Chia-Min Yang

    2014-12-01

    Conclusion: The overall complication rate in the present study was comparable to that reported in previous studies, although our patients had a larger mean tumor size and higher-complexity procedures.

  17. Compatriot partiality and cosmopolitan justice: Can we justify compatriot partiality within the cosmopolitan framework?

    Directory of Open Access Journals (Sweden)

    Rachelle Bascara

    2016-10-01

    Full Text Available This paper shows an alternative way in which compatriot partiality could be justified within the framework of global distributive justice. Philosophers who argue that compatriot partiality is similar to racial partiality capture something correct about compatriot partiality. However, the analogy should not lead us to comprehensively reject compatriot partiality. We can justify compatriot partiality on the same grounds that liberation movements and affirmative action have been justified. Hence, given cosmopolitan demands of justice, special consideration for the economic well-being of your nation as a whole is justified if and only if the country it identifies is an oppressed developing nation in an unjust global order.This justification is incomplete. We also need to say why Person A, qua national of Country A, is justified in helping her compatriots in Country A over similarly or slightly more oppressed non-compatriots in Country B. I argue that Person A’s partiality towards her compatriots admits further vindication because it is part of an oppressed group’s project of self-emancipation, which is preferable to paternalistic emancipation.Finally, I identify three benefits in my justification for compatriot partiality. First, I do not offer a blanket justification for all forms of compatriot partiality. Partiality between members of oppressed groups is only a temporary effective measure designed to level an unlevel playing field. Second, because history attests that sovereign republics could arise as a collective response to colonial oppression, justifying compatriot partiality on the grounds that I have identified is conducive to the development of sovereignty and even democracy in poor countries, thereby avoiding problems of infringement that many humanitarian poverty alleviation efforts encounter. Finally, my justification for compatriot partiality complies with the implicit cosmopolitan commitment to the realizability of global justice

  18. Essays on partial retirement

    NARCIS (Netherlands)

    Kantarci, T.

    2012-01-01

    The five essays in this dissertation address a range of topics in the micro-economic literature on partial retirement. The focus is on the labor market behavior of older age groups. The essays examine the economic and non-economic determinants of partial retirement behavior, the effect of partial

  19. Urinary KIM-1 and AQP-1 in patients with clear renal cell carcinoma: Potential noninvasive biomarkers

    Directory of Open Access Journals (Sweden)

    Mijušković Mirjana

    2016-01-01

    Full Text Available Background/Aim. Kidney injury molecule-1 (KIM-1 and aquaporin-1 (AQP-1 are potential early urinary biomarkers of clear renal cell carcinoma (cRCC. The aim of this study was to ascertain relationship between the urine concentrations KIM-1 and AQP-1 with tumor size, grade, pT stage and type of operation (radical or partial nephrectomy in patients with cRCC. Methods. Urinary concentrations of urinary KIM-1 (uKIM-1 and urinary AQP-1 (uAQP-1 were determined by commercially available ELISA kits. The analysis included 40 patients undergoing partial or radical nephrectomy for cRCC and 40 age- and sex-matched healthy adult volunteers. Results. The median preoperative concentrations of KIM-1 in the cRCC group [0.724 ± 1.120 ng/mg urinary creatinine (Ucr] were significantly greater compared with controls (healthy volunteers (0.210 ± 0.082 ng/mgUcr (p = 0.0227. Postoperatively, uKIM-1 concentration decreased significantly to control values (0.177 ± 0.099 ng/mgUcr vs 0.210 ± 0.082 ng/mgUcr, respectively. The size, grade and stage of tumor were correlated positively with preoperative uKIM-1 concentrations. Contrary to these results, concentrations of uAQP-1 in the cRCC group were significantly lower (0.111 ± 0.092 ng/mgUcr compared with the control group (0.202 ± 0.078 ng/mgUcr (p = 0.0014. Postoperatively, the concentrations of uAQP-1 increased progressively up to control values, approximately. We find no significant correlation between preoperative uAQP-1 concentrations and tumor size, grade and stage. Conclusion. uKIM-1 was found to be a reliable diagnostic marker of cRCC, based on its significantly increased values before and decreased values after the nephrectomy. [Projekat Ministarstva nauke Republike Srbije, br. III41018

  20. MO-E-213-03: Newer Radiation Protection Requirements in Last Decade

    Energy Technology Data Exchange (ETDEWEB)

    Clements, J. [Kaiser Permanente (United States)

    2015-06-15

    The focus of work of medical physicists in 1980’s was on quality control and quality assurance. Radiation safety was important but was dominated by occupational radiation protection. A series of over exposures of patients in radiotherapy, nuclear medicine and observation of skin injuries among patients undergoing interventional procedures in 1990’s started creating the need for focus on patient protection. It gave medical physicists new directions to develop expertise in patient dosimetry and dose management. Publications creating awareness on cancer risks from CT in early part of the current century and over exposures in CT in 2008 brought radiation risks in public domain and created challenging situations for medical physicists. Increasing multiple exposures of individual patient and patient doses of few tens of mSv or exceeding 100 mSv are increasing the role of medical physicists. Expansion of usage of fluoroscopy in the hands of clinical professionals with hardly any training in radiation protection shall require further role for medical physicists. The increasing publications in journals, recent changes in Safety Standards, California law, all increase responsibilities of medical physicists in patient protection. Newer technological developments in dose efficiency and protective devices increase percentage of time devoted by medical physicists on radiation protection activities. Without radiation protection, the roles, responsibilities and day-to-day involvement of medical physicists in diagnostic radiology becomes questionable. In coming years either medical radiation protection may emerge as a specialty or medical physicists will have to keep major part of day-to-day work on radiation protection. Learning Objectives: To understand how radiation protection has been increasing its role in day-to-day activities of medical physicist To be aware about international safety Standards, national and State regulations that require higher attention to radiation

  1. Intra-operative ultrasound-based augmented reality guidance for laparoscopic surgery.

    Science.gov (United States)

    Singla, Rohit; Edgcumbe, Philip; Pratt, Philip; Nguan, Christopher; Rohling, Robert

    2017-10-01

    In laparoscopic surgery, the surgeon must operate with a limited field of view and reduced depth perception. This makes spatial understanding of critical structures difficult, such as an endophytic tumour in a partial nephrectomy. Such tumours yield a high complication rate of 47%, and excising them increases the risk of cutting into the kidney's collecting system. To overcome these challenges, an augmented reality guidance system is proposed. Using intra-operative ultrasound, a single navigation aid, and surgical instrument tracking, four augmentations of guidance information are provided during tumour excision. Qualitative and quantitative system benefits are measured in simulated robot-assisted partial nephrectomies. Robot-to-camera calibration achieved a total registration error of 1.0 ± 0.4 mm while the total system error is 2.5 ± 0.5 mm. The system significantly reduced healthy tissue excised from an average (±standard deviation) of 30.6 ± 5.5 to 17.5 ± 2.4 cm 3 ( p < 0.05) and reduced the depth from the tumor underside to cut from an average (±standard deviation) of 10.2 ± 4.1 to 3.3 ± 2.3 mm ( p < 0.05). Further evaluation is required in vivo, but the system has promising potential to reduce the amount of healthy parenchymal tissue excised.

  2. Initial laboratory experience with a novel ultrasound probe for standard and single-port robotic kidney surgery: increasing console surgeon autonomy and minimizing instrument clashing.

    Science.gov (United States)

    Yakoubi, Rachid; Autorino, Riccardo; Laydner, Humberto; Guillotreau, Julien; White, Michael A; Hillyer, Shahab; Spana, Gregory; Khanna, Rakesh; Isaac, Wahib; Haber, Georges-Pascal; Stein, Robert J; Kaouk, Jihad H

    2012-06-01

    The aim of this study was to evaluate a novel ultrasound probe specifically developed for robotic surgery by determining its efficiency in identifying renal tumors. The study was carried out using the Da Vinci™ surgical system in one female pig. Renal tumor targets were created by percutaneous injection of a tumor mimic mixture. Single-port and standard robotic partial nephrectomy were performed. Intraoperative ultrasound was performed using both standard laparoscopic probe and the new ProART™ Robotic probe. Probe maneuverability and ease of handling for tumor localization were recorded. The standard laparoscopic probe was guided by the assistant. Significant clashing with robotic arms was noted during the single-port procedure. The novel robotic probe was easily introduced through the assistant trocar, and held by the console surgeon using the robotic Prograsp™ with no registered clashing in the external operative field. The average time for grasping the new robotic probe was less than 10 s. Once inserted and grasped, no limitation was found in terms of instrument clashing during the single-port procedure. This novel ultrasound probe developed for robotic surgery was noted to be user-friendly when performing porcine standard and especially single-port robotic partial nephrectomy. Copyright © 2011 John Wiley & Sons, Ltd.

  3. Pain Elimination during Injection with Newer Electronic Devices: A Comparative Evaluation in Children.

    Science.gov (United States)

    Bansal, Neha; Saha, Sonali; Jaiswal, Jn; Samadi, Firoza

    2014-05-01

    The present study was taken up to clinically evaluate and compare effectiveness of transcutaneous electrical nerve stimulator (TENS) and comfort control syringe (CCS) in various pediatric dental procedures as an alternative to the conventional method of local anesthesia (LA) administration. Ninety healthy children having at least one deciduous molar tooth indicated for extraction in either maxillary right or left quadrant in age group of 6 to 10 years were randomly divided into three equal groups having 30 subjects each. Group I: LA administration using conventional syringe, group II: LA administration using TENS along with the conventional syringe, group III: LA administration using CCS. After LA by the three techniques, pain, anxiety and heart rate were measured. The observations, thus, obtained were subjected to statistical analysis using analysis of variance (ANOVA), student t-test and paired t-test. The mean pain score was maximum in group I followed by group II, while group III revealed the minimum pain, where LA was administered using CCS. Mean anxiety score was maximum in group I followed by group II, while group III revealed the minimum score. Mean heart rate was maximum in group I followed in descending order by groups II and III. The study supports the belief that CCS could be a viable alternative in comparison to the other two methods of LA delivery in children. How to cite this article: Bansal N, Saha S, Jaiswal JN, Samadi F. Pain Elimination during Injection with Newer Electronic Devices: A Comparative Evaluation in Children. Int J Clin Pediatr Dent 2014;7(2):71-76.

  4. Systematic Review of Efficacy and Safety of Newer Antidiabetic Drugs Approved from 2013 to 2017 in Controlling HbA1c in Diabetes Patients

    Directory of Open Access Journals (Sweden)

    Sivanandy Palanisamy

    2018-06-01

    Full Text Available Type 2 Diabetes Mellitus (T2DM is the most common form of diabetes mellitus and accounts for about 95% of all diabetes cases. Many newer oral as well as parenteral antidiabetic drugs have been introduced in to the market in recent years to control hyperglycemic conditions in diabetes patients and many of these drugs produce potential side effects in diabetes patients. Hence, this systematic review was aimed to analyze and compare the efficacy and safety of oral antidiabetic agents in controlling HbA1c in T2DM patients, that were approved by the United States-Food and Drug Administration (US-FDA from 2013 to 2017. All randomized controlled, double-blind trials published in English during the search period involving the newer antidiabetic agents were selected. In the outcome assessment comparison, semaglutide demonstrated the highest efficacy in lowering HbA1c, with a 1.6% reduction (p < 0.0001 when given at a dose of 1.0 mg. The safety profile of all the agents as compared to placebo or control were similar, with no or slight increase in the occurrence of adverse events (AEs but no fatal reaction was reported. The most common AEs of all the antidiabetic agents were gastrointestinal in nature, with several cases of hypoglycemic events. However, among all these agents, semaglutide seems to be the most efficacious drug to improve glycemic control in terms of HbA1c. Alogliptin has the least overall frequency of AEs compared to other treatment groups.

  5. The treatment of type 2 diabetes in the presence of renal impairment: what we should know about newer therapies

    Directory of Open Access Journals (Sweden)

    Davies M

    2016-06-01

    Full Text Available Melanie Davies,1,2 Sudesna Chatterjee,1,2 Kamlesh Khunti1,2 1Diabetes Research Centre, University of Leicester, 2Leicester Diabetes Centre, University Hospitals of Leicester NHS Trust, Leicester, UK Abstract: Worldwide, an estimated 200 million people have chronic kidney disease (CKD, the most common causes of which include hypertension, arteriosclerosis, and diabetes. Importantly, ~40% of patients with diabetes develop CKD, yet evidence from major multicenter randomized controlled trials shows that intensive blood glucose control through pharmacological intervention can reduce the incidence and progression of CKD. Standard therapies for the treatment of type 2 diabetes include metformin, sulfonylureas, meglitinides, thiazolidinediones, and insulin. While these drugs have an important role in the management of type 2 diabetes, only the thiazolidinedione pioglitazone can be used across the spectrum of CKD (stages 2–5 and without dose adjustment; there are contraindications and dose adjustments required for the remaining standard therapies. Newer therapies, particularly dipeptidyl peptidase-IV inhibitors, glucagon-like peptide-1 receptor agonists, and sodium-glucose cotransporter-2 inhibitors, are increasingly being used in the treatment of type 2 diabetes; however, a major consideration is whether these newer therapies can also be used safely and effectively across the spectrum of renal impairment. Notably, reductions in albuminuria, a marker of CKD, are observed with many of the drug classes. Dipeptidyl peptidase-IV inhibitors can be used in all stages of renal impairment, with appropriate dose reduction, with the exception of linagliptin, which can be used without dose adjustment. No dose adjustment is required for liraglutide, albiglutide, and dulaglutide in CKD stages 2 and 3, although all glucagon-like peptide-1 receptor agonists are currently contraindicated in stages 4 and 5 CKD. At stage 3 CKD or greater, the sodium

  6. Computed tomography, after abdominal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, H.; Toedt, H.C.

    1985-09-01

    The CT-examinations of 131 patients were analyzed after abdominal surgery. After nephrectomy, splenectomy, partial hepatectomy and pancreatectomy a displacement of the neighbouring intraabdominal and retroperitoneal organs was seen. Scar-tissue was observed containing fat, which faciltated the differential diagnosis to tumor recurrency. The changes of the roentgenmorphology were not so obvious after gastrointestinal surgery. After vascular surgery the permeability of an anastomosis or an operated artery could be demonstrated by bolus injection. (orig.).

  7. Computed tomography, after abdominal surgery

    International Nuclear Information System (INIS)

    Vogel, H.; Toedt, H.C.; Hamburg Univ.

    1985-01-01

    The CT-examinations of 131 patients were analyzed after abdominal surgery. After nephrectomy, splenectomy, partial hepatectomy and pancreatectomy a displacement of the neighbouring intraabdominal and retroperitoneal organs was seen. Scar-tissue was observed containing fat, which fascilated the differentialdiagnosis to tumorrecurrency. The changes of the roentgenmorphology were not so abvious after gastro-intestinal surgery. After vascular surgery the permeability of an anastomosis or an operated artery could be demonstrated by bolusinjection. (orig.) [de

  8. MR imaging of renal cell carcinoma: associations among signal intensity, tumor enhancement, and pathologic findings.

    OpenAIRE

    Yabuki, Takayuki; Togami, Izumi; Kitagawa, Takahiro; Sasai, Nobuya; Tsushima, Tomoyasu; Shirasaki, Yoshinori; Hiraki, Yoshio

    2003-01-01

    The purpose of this study was to compare the MR characteristics of renal cell carcinomas against histologic findings and to assess the correlations among signal intensity, tumor enhancement, and pathologic findings. Fifty-four patients (56 lesions) were examined by MR imaging and then underwent partial or radical nephrectomy. The pathologic diagnosis of all lesions was renal cell carcinoma. All MR examinations were performed as dynamic studies using the same 1.5-T scanner. MR characteristics ...

  9. Adverse cardiac effects of exogenous angiotensin 1-7 in rats with subtotal nephrectomy are prevented by ACE inhibition.

    Directory of Open Access Journals (Sweden)

    Louise M Burrell

    Full Text Available We previously reported that exogenous angiotensin (Ang 1-7 has adverse cardiac effects in experimental kidney failure due to its action to increase cardiac angiotensin converting enzyme (ACE activity. This study investigated if the addition of an ACE inhibitor (ACEi to Ang 1-7 infusion would unmask any beneficial effects of Ang 1-7 on the heart in experimental kidney failure. Male Sprague-Dawley rats underwent subtotal nephrectomy (STNx and were treated with vehicle, the ACEi ramipril (oral 1mg/kg/day, Ang 1-7 (subcutaneous 24 μg/kg/h or dual therapy (all groups, n = 12. A control group (n = 10 of sham-operated rats were also studied. STNx led to hypertension, renal impairment, cardiac hypertrophy and fibrosis, and increased both left ventricular ACE2 activity and ACE binding. STNx was not associated with changes in plasma levels of ACE, ACE2 or angiotensin peptides. Ramipril reduced blood pressure, improved cardiac hypertrophy and fibrosis and inhibited cardiac ACE. Ang 1-7 infusion increased blood pressure, cardiac interstitial fibrosis and cardiac ACE binding compared to untreated STNx rats. Although in STNx rats, the addition of ACEi to Ang 1-7 prevented any deleterious cardiac effects of Ang 1-7, a limitation of the study is that the large increase in plasma Ang 1-7 with ramipril may have masked any effect of infused Ang 1-7.

  10. The effect of kidney morcellation on operative time, incision complications, and postoperative analgesia after laparoscopic nephrectomy

    Directory of Open Access Journals (Sweden)

    Affonso H. Camargo

    2006-06-01

    Full Text Available INTRODUCTION: Compare the outcomes between kidney morcellation and two types of open specimen extraction incisions, several covariates need to be taken into consideration that have not yet been studied. MATERIALS AND METHODS: We retrospectively reviewed 153 consecutive patients who underwent laparoscopic nephrectomy at our institution, 107 who underwent specimen morcellation and 46 with intact specimen removal, either those with connected port sites with a muscle-cutting incision and those with a remote, muscle-splitting incision. Operative time, postoperative analgesia requirements, and incisional complications were evaluated using univariate and multivariate analysis, comparing variables such as patient age, gender, body mass index (BMI, laterality, benign versus cancerous renal conditions, estimated blood loss, specimen weight, overall complications, and length of stay. RESULTS: There was no significant difference for operative time between the 2 treatment groups (p = 0.65. Incision related complications occurred in 2 patients (4.4% from the intact specimen group but none in the morcellation group (p = 0.03. Overall narcotic requirement was lower in patients with morcellated (41 mg compared to intact specimen retrieval (66 mg on univariate (p = 0.03 and multivariate analysis (p = 0.049. Upon further stratification, however, there was no significant difference in mean narcotic requirement between the morcellation and muscle-splitting incision subgroup (p = 0.14. CONCLUSION: Morcellation does not extend operative time, and is associated with significantly less postoperative pain compared to intact specimen retrieval overall, although this is not statistically significant if a remote, muscle-splitting incision is made. Morcellation markedly reduces the risk of incisional-related complications.

  11. Tutorial on Online Partial Evaluation

    Directory of Open Access Journals (Sweden)

    William R. Cook

    2011-09-01

    Full Text Available This paper is a short tutorial introduction to online partial evaluation. We show how to write a simple online partial evaluator for a simple, pure, first-order, functional programming language. In particular, we show that the partial evaluator can be derived as a variation on a compositionally defined interpreter. We demonstrate the use of the resulting partial evaluator for program optimization in the context of model-driven development.

  12. Clinical implications of a rare renal entity: Pleomorphic Hyalinizing Angiectatic Tumor (PHAT).

    Science.gov (United States)

    Scalici Gesolfo, Cristina; Serretta, Vincenzo; Di Maida, Fabrizio; Giannone, Giulio; Barresi, Elisabetta; Franco, Vito; Montironi, Rodolfo

    2017-02-01

    Pleomorphic Hyalinizing Angiectatic Tumor (PHAT) is a rare benign lesion characterized by slow growth, infiltrative behavior and high rate of local recurrences. Only one case has been described in retroperitoneum, at renal hilum, but not involving pelvis or parenchyma. Here we present the first case of PHAT arising in the renal parenchyma. A nodular lesion in right kidney lower pole was diagnosed to a 61 year old woman. The patient underwent right nephrectomy. Microscopically, the lesion showed solid and pseudo-cystic components with hemorrhagic areas characterized by aggregates of ectatic blood vessels. Pleomorphic cells were characterized by large eosinophilic cytoplasm with irregular and hyperchromatic nuclei. Immunohistochemistry was performed and the lesion was classified as a Pleomorphic Hyalinizing Angiectatic Tumor (PHAT). Due to the clinical behavior of this tumor, in spite of its benign nature, review of the surgical margins and close follow up after partial nephrectomy are mandatory. Copyright © 2016. Published by Elsevier GmbH.

  13. The effect of newer anti-rheumatic drugs on osteogenic cell proliferation: an in-vitro study

    Directory of Open Access Journals (Sweden)

    Laing Patrick

    2009-05-01

    Full Text Available Abstract Background Disease modifying anti-rheumatic drugs (DMARDs may interfere with bone healing. Previous studies give conflicting advice regarding discontinuation of these drugs in the peri-operative setting. No consensus exists in current practice especially with the newer DMARDs such as Leflunomide, Etanercept, and Infliximab. The aim of this study was to assess the in-vitro effect of these drugs alone and in relevant clinical combinations on Osteoblast activity. Methods Osteoblasts were cultured from femoral heads obtained from five young otherwise healthy patients undergoing total hip replacement. The cells were cultured using techniques that have been previously described. A full factorial design was used to set up the experiment on samples obtained from the five donors. Normal therapeutic concentrations of the various DMARDs were added alone and in combination to the media. The cell proliferation was estimated after two weeks using spectrophotometric technique using Roche Cell proliferation Kit. Multilevel regression analysis was used to estimate which drugs or combination of drugs significantly affected cell proliferation. Results Infliximab and Leflunomide had an overall significant inhibitory effect (p Conclusion Our study indicates that in-vitro osteoblast proliferation can be inhibited by the presence of certain DMARDs. Combinations of drugs had an influence and could negate the action of a drug on osteoblast proliferation. The response to drugs may be donor-dependent.

  14. An Assessment of Five (PANSS, SAPS, SANS, NSA-16, CGI-SCH) commonly used Symptoms Rating Scales in Schizophrenia and Comparison to Newer Scales (CAINS, BNSS).

    Science.gov (United States)

    Kumari, Suneeta; Malik, Mansoor; Florival, Christina; Manalai, Partam; Sonje, Snezana

    2017-01-01

    Scales measuring positive and negative symptoms in schizophrenia remain the primary mo Scales measuring positive and negative symptoms in schizophrenia remain the primary mode of assessing and diagnosing schizophrenia by clinicians and researchers. The scales are mainly used to monitor the severity of positive and negative symptoms and track treatment response in schizophrenics. Although these scales are widely used, quality as well as general utility of each scale varies. The quality is determined by the validity and reliability of the scales. The utility of the scale is determined by the time of administration and the settings for which the scales can be administered in research or clinical settings. There are relatively fewer articles on the utility of newer scales like CAINS (Clinical Assessment Interview for Negative Symptoms) and the BNSS (Brief Negative Symptom Scale) that compare them to the older scales PANSS (Positive and Negative Symptoms Scale), SAPS (Scale for the Assessment of Positive Symptoms) SANS (the Scale for the Assessment of Negative Symptoms), NSA-16 (Negative Symptom Assessment-16) and CGI-SCH (Clinical Global Impression Schizophrenia. The older scales were developed more than 30 years ago. Since then, our understanding of negative symptoms has evolved and currently there are newer rating scales evaluating the validity of negative symptoms. The older scales do not incorporate the latest research on negative symptoms. CAINS and BNSS are attractive for both their reliability and their concise accessible format, however, a scale that is simpler, accessible, user-friendly, that incorporates a multidimensional model of schizophrenia, addresses the psychosocial and cognitive component has yet to be developed.

  15. Partially Observed Mixtures of IRT Models: An Extension of the Generalized Partial-Credit Model

    Science.gov (United States)

    Von Davier, Matthias; Yamamoto, Kentaro

    2004-01-01

    The generalized partial-credit model (GPCM) is used frequently in educational testing and in large-scale assessments for analyzing polytomous data. Special cases of the generalized partial-credit model are the partial-credit model--or Rasch model for ordinal data--and the two parameter logistic (2PL) model. This article extends the GPCM to the…

  16. Partial lesions of the intratemporal segment of the facial nerve: graft versus partial reconstruction.

    Science.gov (United States)

    Bento, Ricardo F; Salomone, Raquel; Brito, Rubens; Tsuji, Robinson K; Hausen, Mariana

    2008-09-01

    In cases of partial lesions of the intratemporal segment of the facial nerve, should the surgeon perform an intraoperative partial reconstruction, or partially remove the injured segment and place a graft? We present results from partial lesion reconstruction on the intratemporal segment of the facial nerve. A retrospective study on 42 patients who presented partial lesions on the intratemporal segment of the facial nerve was performed between 1988 and 2005. The patients were divided into 3 groups based on the procedure used: interposition of the partial graft on the injured area of the nerve (group 1; 12 patients); keeping the preserved part and performing tubulization (group 2; 8 patients); and dividing the parts of the injured nerve (proximal and distal) and placing a total graft of the sural nerve (group 3; 22 patients). Fracture of the temporal bone was the most frequent cause of the lesion in all groups, followed by iatrogenic causes (p lesion of the facial nerve is still questionable. Among these 42 patients, the best results were those from the total graft of the facial nerve.

  17. Full-length VP2 gene analysis of canine parvovirus reveals emergence of newer variants in India.

    Science.gov (United States)

    Nookala, Mangadevi; Mukhopadhyay, Hirak Kumar; Sivaprakasam, Amsaveni; Balasubramanian, Brindhalakshmi; Antony, Prabhakar Xavier; Thanislass, Jacob; Srinivas, Mouttou Vivek; Pillai, Raghavan Madhusoodanan

    2016-12-01

    The canine parvovirus (CPV) infection is a highly contagious and serious enteric disease of dogs with high fatality rate. The present study was taken up to characterize the full-length viral polypeptide 2 (VP2) gene of CPV of Indian origin along with the commercially available vaccines. The faecal samples from parvovirus suspected dogs were collected from various states of India for screening by PCR assay and 66.29% of samples were found positive. Six CPV-2a, three CPV-2b, and one CPV-2c types were identified by sequence analysis. Several unique and existing mutations have been noticed in CPV types analyzed indicating emergence of newer variants of CPV in India. The phylogenetic analysis revealed that all the field CPV types were grouped in different subclades within two main clades, but away from the commercial vaccine strains. CPV-2b and CPV-2c types with unique mutations were found to be establishing in India apart from the prevailing CPV-2a type. Mutations and the positive selection of the mutants were found to be the major mechanism of emergence and evolution of parvovirus. Therefore, the incorporation of local strain in the vaccine formulation may be considered for effective control of CPV infections in India.

  18. Partial twisting for scalar mesons

    International Nuclear Information System (INIS)

    Agadjanov, Dimitri; Meißner, Ulf-G.; Rusetsky, Akaki

    2014-01-01

    The possibility of imposing partially twisted boundary conditions is investigated for the scalar sector of lattice QCD. According to the commonly shared belief, the presence of quark-antiquark annihilation diagrams in the intermediate state generally hinders the use of the partial twisting. Using effective field theory techniques in a finite volume, and studying the scalar sector of QCD with total isospin I=1, we however demonstrate that partial twisting can still be performed, despite the fact that annihilation diagrams are present. The reason for this are delicate cancellations, which emerge due to the graded symmetry in partially quenched QCD with valence, sea and ghost quarks. The modified Lüscher equation in case of partial twisting is given

  19. Complex pattern of colon cancer recurrence including a kidney metastasis: A case report

    OpenAIRE

    Waleczek, Helfried; Wente, Moritz N; Kozianka, Jürgen

    2005-01-01

    We report a case of a 77-year-old female with a local recurrence of cancer after right hemicolectomy which infiltrated the pancreatic head affording pancrea-toduodenectomy, who developed 3 years later recurrent tumor masses localized in the mesentery of the jejunum and in the lower pole of the left kidney. Partial nephrectomy and a segment resection of the small bowel were performed. Histological examination of both specimens revealed a necrotic metastasis of the primary carcinoma of the colo...

  20. Partial order infinitary term rewriting

    DEFF Research Database (Denmark)

    Bahr, Patrick

    2014-01-01

    We study an alternative model of infinitary term rewriting. Instead of a metric on terms, a partial order on partial terms is employed to formalise convergence of reductions. We consider both a weak and a strong notion of convergence and show that the metric model of convergence coincides with th...... to the metric setting -- orthogonal systems are both infinitarily confluent and infinitarily normalising in the partial order setting. The unique infinitary normal forms that the partial order model admits are Böhm trees....

  1. Beginning partial differential equations

    CERN Document Server

    O'Neil, Peter V

    2011-01-01

    A rigorous, yet accessible, introduction to partial differential equations-updated in a valuable new edition Beginning Partial Differential Equations, Second Edition provides a comprehensive introduction to partial differential equations (PDEs) with a special focus on the significance of characteristics, solutions by Fourier series, integrals and transforms, properties and physical interpretations of solutions, and a transition to the modern function space approach to PDEs. With its breadth of coverage, this new edition continues to present a broad introduction to the field, while also addres

  2. Hyperbolic partial differential equations

    CERN Document Server

    Witten, Matthew

    1986-01-01

    Hyperbolic Partial Differential Equations III is a refereed journal issue that explores the applications, theory, and/or applied methods related to hyperbolic partial differential equations, or problems arising out of hyperbolic partial differential equations, in any area of research. This journal issue is interested in all types of articles in terms of review, mini-monograph, standard study, or short communication. Some studies presented in this journal include discretization of ideal fluid dynamics in the Eulerian representation; a Riemann problem in gas dynamics with bifurcation; periodic M

  3. Partial differential equations

    CERN Document Server

    Evans, Lawrence C

    2010-01-01

    This text gives a comprehensive survey of modern techniques in the theoretical study of partial differential equations (PDEs) with particular emphasis on nonlinear equations. The exposition is divided into three parts: representation formulas for solutions; theory for linear partial differential equations; and theory for nonlinear partial differential equations. Included are complete treatments of the method of characteristics; energy methods within Sobolev spaces; regularity for second-order elliptic, parabolic, and hyperbolic equations; maximum principles; the multidimensional calculus of variations; viscosity solutions of Hamilton-Jacobi equations; shock waves and entropy criteria for conservation laws; and, much more.The author summarizes the relevant mathematics required to understand current research in PDEs, especially nonlinear PDEs. While he has reworked and simplified much of the classical theory (particularly the method of characteristics), he primarily emphasizes the modern interplay between funct...

  4. Partial Cooperative Equilibria: Existence and Characterization

    Directory of Open Access Journals (Sweden)

    Amandine Ghintran

    2010-09-01

    Full Text Available We study the solution concepts of partial cooperative Cournot-Nash equilibria and partial cooperative Stackelberg equilibria. The partial cooperative Cournot-Nash equilibrium is axiomatically characterized by using notions of rationality, consistency and converse consistency with regard to reduced games. We also establish sufficient conditions for which partial cooperative Cournot-Nash equilibria and partial cooperative Stackelberg equilibria exist in supermodular games. Finally, we provide an application to strategic network formation where such solution concepts may be useful.

  5. Post-operative pain after ultrasound transversus abdominis plane block versus trocar site infiltration in laparoscopic nephrectomy: a prospective study

    Directory of Open Access Journals (Sweden)

    Ana M. Araújo

    2017-09-01

    Full Text Available Background: Transversus abdominis plane (TAP block is useful in reducing post-operative pain in laparoscopic nephrectomy compared to placebo. The purpose of this work is to compare post-operative pain and recovery after TAP block or trocar site infiltration (TSI in this surgery. Methods: A prospective, single blinded study on patients scheduled for laparoscopic nephrectomy. Patients were assigned to two groups: TSI Group: trocar site infiltration at the end of surgery; TAP Group: unilateral ultrasound-guided TAP block after induction. Sevoflurane and remifentanil, in a target controlled infusion mode, were used for maintenance of general anesthesia. Before the end of surgery paracetamol, tramadol and morphine were administered. Visual analogue scale (VAS 0–100 mm at rest and with cough was applied in three moments: in recovery room (T1 at admission and T2 before discharge and 24 h after surgery (T3. Pain scores with incentive spirometer were also evaluated at T3. In recovery, morphine was administered as a rescue drug whenever VAS > 30 mm. Time to oral intake, chair sitting, ambulation and length of hospital stay were evaluated 24 h after surgery. Statistical analysis: Student's t-test and Chi-square test, and linear regression models. A p-value  0.05. VAS at rest (TAP vs. TSI groups was: T1 = 33 ± 29 vs. 39 ± 32, T2 = 10 ± 9 vs. 17 ± 18 and T3 = 7 ± 12 vs. 10 ± 18. VAS with cough (TAP vs. TSI groups was: T1 = 51 ± 34 vs. 45 ± 32, T2 = 24 ± 24 vs. 33 ± 23 and T3 = 20 ± 23 vs. 23 ± 23. VAS with incentive spirometer (TAP vs. TSI groups was: T3 = 21 ± 27 vs. 21 ± 25. Intraoperative remifentanil consumption was similar between TAP (0.16 ± 0.07 mcg.kg−1.min−1 and TSI (0.18 ± 0.9 mcg.kg−1.min−1 groups. There were no differences in opioid consumption between TAP (4.4 ± 3.49 mg and TSI (6.87 ± 4.83 mg groups during recovery. Functional recovery parameters were not

  6. Successful removable partial dentures.

    Science.gov (United States)

    Lynch, Christopher D

    2012-03-01

    Removable partial dentures (RPDs) remain a mainstay of prosthodontic care for partially dentate patients. Appropriately designed, they can restore masticatory efficiency, improve aesthetics and speech, and help secure overall oral health. However, challenges remain in providing such treatments, including maintaining adequate plaque control, achieving adequate retention, and facilitating patient tolerance. The aim of this paper is to review the successful provision of RPDs. Removable partial dentures are a successful form of treatment for replacing missing teeth, and can be successfully provided with appropriate design and fabrication concepts in mind.

  7. 32 CFR 751.13 - Partial payments.

    Science.gov (United States)

    2010-07-01

    ... voucher and all other information related to the partial payment shall be placed in the claim file. Action... 32 National Defense 5 2010-07-01 2010-07-01 false Partial payments. 751.13 Section 751.13 National... Claims Against the United States § 751.13 Partial payments. (a) Partial payments when hardship exists...

  8. Evolving practice patterns for the management of small renal masses in the USA.

    Science.gov (United States)

    Yang, Glen; Villalta, Jacqueline D; Meng, Maxwell V; Whitson, Jared M

    2012-10-01

    What's known on the subject? and What does the study add? Treatment options for small renal masses include radical nephrectomy (RN), partial nephrectomy (PN), ablation, and surveillance. PN provides equivalent oncological as RN for small tumours, but long-term outcomes for ablation and surveillance are poorly defined. Due to changing techniques and technology, treatment patterns for small renal masses are rapidly developing. Prior studies had analysed utilisation trends for PN and RN to 2006, revealing a relative rise in the rate of PN. However, overall treatment trends including surveillance and ablation had not been studied using a population-based cohort. It has become increasingly clear that RN is associated with greater renal and cardiovascular deterioration than nephron-sparing treatments. Thus, it is important to understand current population-based practice patterns for the treatment of small renal masses to assess whether practitioners are adhering to ever-changing principles in this field. The present study provides up-to-date treatment trends in the USA using a large population-based cohort. To describe the changing practice patterns in the management of small renal masses, including the use of surveillance and ablative techniques. All patients in the Surveillance, Epidemiology and End Results (SEER) registry treated for renal masses of ≤7 cm in diameter, from 1998 to 2008, were included for analysis. Annual trends in the use of surveillance, ablation, partial nephrectomy (PN), and radical nephrectomy (RN) were calculated. Multinomial logistic regression was used to determine the association of demographic and clinical characteristics with treatment method. In all, 48 148 patients from 17 registry sites with a mean age of 63.4 years were included for analysis. Between 1998 and 2008, for masses of vs 50%, 16% vs 33%, respectively) and ablation (1% vs 11%, 2% vs 9%, respectively). In multivariable analysis, later year of diagnosis, male gender, being

  9. [Acrylic resin removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Creugers, N H J

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of removable partial dentures, the acrylic resin removable partial denture has 3 favourable aspects: the economic aspect, its aesthetic quality and the ease with which it can be extended and adjusted. Disadvantages are an increased risk of caries developing, gingivitis, periodontal disease, denture stomatitis, alveolar bone reduction, tooth migration, triggering of the gag reflex and damage to the acrylic resin base. Present-day indications are ofa temporary or palliative nature or are motivated by economic factors. Special varieties of the acrylic resin removable partial denture are the spoon denture, the flexible denture fabricated of non-rigid acrylic resin, and the two-piece sectional denture. Furthermore, acrylic resin removable partial dentures can be supplied with clasps or reinforced by fibers or metal wires.

  10. Laparoscopic partial nephrectomy: A series of one hundred cases performed by the same surgeon

    Directory of Open Access Journals (Sweden)

    José M Campero

    2012-01-01

    Conclusions: Our results are similar to those reported in the international literature. LPN is a challenging surgical technique that in hands of a trained and experienced surgeon has excellent and reproducible results for the management of small renal masses and cysts.

  11. Partial Actions and Power Sets

    Directory of Open Access Journals (Sweden)

    Jesús Ávila

    2013-01-01

    Full Text Available We consider a partial action (X,α with enveloping action (T,β. In this work we extend α to a partial action on the ring (P(X,Δ,∩ and find its enveloping action (E,β. Finally, we introduce the concept of partial action of finite type to investigate the relationship between (E,β and (P(T,β.

  12. Algorithms over partially ordered sets

    DEFF Research Database (Denmark)

    Baer, Robert M.; Østerby, Ole

    1969-01-01

    in partially ordered sets, answer the combinatorial question of how many maximal chains might exist in a partially ordered set withn elements, and we give an algorithm for enumerating all maximal chains. We give (in § 3) algorithms which decide whether a partially ordered set is a (lower or upper) semi......-lattice, and whether a lattice has distributive, modular, and Boolean properties. Finally (in § 4) we give Algol realizations of the various algorithms....

  13. Partial Deconvolution with Inaccurate Blur Kernel.

    Science.gov (United States)

    Ren, Dongwei; Zuo, Wangmeng; Zhang, David; Xu, Jun; Zhang, Lei

    2017-10-17

    Most non-blind deconvolution methods are developed under the error-free kernel assumption, and are not robust to inaccurate blur kernel. Unfortunately, despite the great progress in blind deconvolution, estimation error remains inevitable during blur kernel estimation. Consequently, severe artifacts such as ringing effects and distortions are likely to be introduced in the non-blind deconvolution stage. In this paper, we tackle this issue by suggesting: (i) a partial map in the Fourier domain for modeling kernel estimation error, and (ii) a partial deconvolution model for robust deblurring with inaccurate blur kernel. The partial map is constructed by detecting the reliable Fourier entries of estimated blur kernel. And partial deconvolution is applied to wavelet-based and learning-based models to suppress the adverse effect of kernel estimation error. Furthermore, an E-M algorithm is developed for estimating the partial map and recovering the latent sharp image alternatively. Experimental results show that our partial deconvolution model is effective in relieving artifacts caused by inaccurate blur kernel, and can achieve favorable deblurring quality on synthetic and real blurry images.Most non-blind deconvolution methods are developed under the error-free kernel assumption, and are not robust to inaccurate blur kernel. Unfortunately, despite the great progress in blind deconvolution, estimation error remains inevitable during blur kernel estimation. Consequently, severe artifacts such as ringing effects and distortions are likely to be introduced in the non-blind deconvolution stage. In this paper, we tackle this issue by suggesting: (i) a partial map in the Fourier domain for modeling kernel estimation error, and (ii) a partial deconvolution model for robust deblurring with inaccurate blur kernel. The partial map is constructed by detecting the reliable Fourier entries of estimated blur kernel. And partial deconvolution is applied to wavelet-based and learning

  14. Comparative clinical study of conjunctival toxicities of newer generation fluoroquinolones without the influence of preservatives

    Directory of Open Access Journals (Sweden)

    Han Sang Park

    2015-12-01

    Full Text Available To compare the conjunctival epithelial toxicities of three newer-generation fluoroquinolones without preservatives. In a prospective, randomized, double blind comparative study, 47 eyes of 47 patients with a primary pterygium were enrolled, and divided randomly into three groups (levofloxacin 0.5%, gatifloxacin 0.3%, and moxifloxacin 0.5%. After pterygium surgery with the same conjunctival autograft technique, each patient maintained a regimen with a randomly assigned fluoroquinolone eye drop. Patients were examined every other day after surgery until the epithelium had completely healed. Photos were taken and used to measure the area of residual epithelial defects. Conjunctival healing time and speed (initial defect area/healing time (mm2/d compared in each group using Kruskal-Wallis tests. There were no significant differences in mean age, gender, and conjunctival defect size of the donor site between these groups. However, the mean of conjunctival healing time and speed were statistically different in each group. The mean of conjunctival epithelial healing time was 8.93±2.69d (levofloxacin group, 10.31±2.96d (gatifloxacin group, and 13.50±4.10d (moxifloxacin group, P=0.006. The mean conjuctival epithelial healing speed was 6.18±1.39 mm2/d (levofloxacin group, 5.52±1.68 mm2/d (gatifloxacin group, and 4.40±1.30 mm2/d (moxifloxacin group, P=0 .003. Without the influence of preservatives, levofloxacin and gatifloxacin might be less toxic to the regeneration of conjunctival epithelial cells and cause a faster conjunctival wound healing relative to moxifloxacin.

  15. Renal cell carcinoma in patients with a solitary kidney after nephrectomy treated with radiofrequency ablation: Mid term results

    International Nuclear Information System (INIS)

    Hoffmann, Ralf-Thorsten; Jakobs, Tobias F.; Kubisch, Constanze H.; Trumm, Christoph; Weber, Christof; Siebels, Michael; Helmberger, Thomas K.; Reiser, Maximilian F.

    2010-01-01

    This retrospective study aimed to evaluate the feasibility and effectiveness of radiofrequency ablation (RFA) in patients with solitary kidney for the treatment of renal cell carcinoma (RCC). Within 2 years 10 patients (seven males, three females; age 65 ± 8 years) were treated. All patients had a history of nephrectomy of the contralateral kidney. The indications for RFA were inoperability or high probability of complete renal failure after surgical enucleation of the tumor. 13 tumors with a size between 1.9 and 4.2 cm (average 2.7 cm) were treated. In patients with a tumor diameter larger than 2.5 cm a transarterial embolization was performed prior to RFA to reduce heat sink effect and risk of bleeding. Therapeutical success was defined as a lack of contrast enhancement in follow up examinations and shrinking of the treated area. Furthermore all patients' renal function was monitored. RFA of renal tumors under CT-fluoroscopy was feasible in all patients. Within the follow up (3 and 24 months) no tumor recurrence or major complication was detected. One patient developed another RCC and was successfully treated with a second RF-ablation. None of the patients developed renal failure with the need of hemodialysis. In one of the patients a hemorrhage into the surrounding tissue was noticed, which stopped spontaneously. RFA is a valuable and effective therapeutical option in patients with solitary kidney suffering from inoperable renal cell carcinoma. The complication rate is small and an excellent tumor control can be achieved without deterioration of the renal function.

  16. Algebraic partial Boolean algebras

    International Nuclear Information System (INIS)

    Smith, Derek

    2003-01-01

    Partial Boolean algebras, first studied by Kochen and Specker in the 1960s, provide the structure for Bell-Kochen-Specker theorems which deny the existence of non-contextual hidden variable theories. In this paper, we study partial Boolean algebras which are 'algebraic' in the sense that their elements have coordinates in an algebraic number field. Several of these algebras have been discussed recently in a debate on the validity of Bell-Kochen-Specker theorems in the context of finite precision measurements. The main result of this paper is that every algebraic finitely-generated partial Boolean algebra B(T) is finite when the underlying space H is three-dimensional, answering a question of Kochen and showing that Conway and Kochen's infinite algebraic partial Boolean algebra has minimum dimension. This result contrasts the existence of an infinite (non-algebraic) B(T) generated by eight elements in an abstract orthomodular lattice of height 3. We then initiate a study of higher-dimensional algebraic partial Boolean algebras. First, we describe a restriction on the determinants of the elements of B(T) that are generated by a given set T. We then show that when the generating set T consists of the rays spanning the minimal vectors in a real irreducible root lattice, B(T) is infinite just if that root lattice has an A 5 sublattice. Finally, we characterize the rays of B(T) when T consists of the rays spanning the minimal vectors of the root lattice E 8

  17. [Removable partial dentures. Oral functions and types].

    Science.gov (United States)

    Creugers, N H J; de Baat, C

    2009-11-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic tissue-supported dentures, dentures with cast metal frameworks en dentures with cast metal frameworks and (semi)precision attachments. Interrupted tooth arches,free-ending tooth arches, and a combination of interrupted as well as free-ending tooth arches can be restored using these dentures. Well-known disadvantages of removable partial dentures are problematic oral hygiene, negative influence on the remaining dentition and limited oral comfort. Due to the advanced possibilities of fixed tooth- or implant-supported partial dentures, whether or not free-ending, or tooth- as well as implant-supported partial dentures, the indication of removable partial dentures is restricted. Nevertheless, for the time being the demand for removable partial dentures is expected to continue.

  18. [Conventional retaining of removable partial dentures

    NARCIS (Netherlands)

    Keltjens, H.M.A.M.; Witter, D.J.; Creugers, N.H.J.

    2009-01-01

    Mechanical and biological criteria have to be met in retaining the metal frame of a removable partial denture. Additionally, a removable partial denture is part of the occlusal interface by the clasps and the denture teeth. With respect to mechanical aspects, all rigid parts of the removable partial

  19. Isolated Renal Hydatid Disease: Experience at the Queen Rania Urology Center, The King Hussein Medical Center

    International Nuclear Information System (INIS)

    Abu-Qamar, Adnan A.; Aljader, Khalaf M.; Habboub, Hazem

    2004-01-01

    In this retrospective study, we present our experience on the diagnosis and management of isolated Hydatid disease of kidneys. Between January 1999 and January 2003, eight patients were diagnosed to have Hydatid disease of kidney and constituted the subjects of this study. Their age ranged between 20 and 63 years age (mean 40); there were five males and three females. Loin pain was the commonest mode of presentation in these patients. Investigations performed included urine analysis, serological tests, eosinophil count and relevant radiological studies. Urine analysis showed hydatiduria in one patient, the Casoni's test was positive in two, Ghedini skin test was positive in three and esinophilia was noted in two other patients. All patients were treated surgically using loin supracoastal extra-peritoneal approach. Total nephrectomy was performed in five patients, partial nephrectomy in one while excision of the cyst was performed in two patients. Our report suggests that a combination of various investigative modalities with a high index of suspicion is necessary in establishing the correct diagnosis. Surgery remains the main option of treatment for renal hydatid disease. (author)

  20. Isolated renal hydatid disease: experience at the queen rania urology center, the king hussein medical center.

    Science.gov (United States)

    Abu-Qamar, Adnan A; Aljader, Khalaf M; Habboub, Hazem

    2004-01-01

    In this retrospective study, we present our experience on the diagnosis and management of isolated Hydatid disease of the kidneys. Between January 1999 and January 2003, eight patients were diagnosed to have Hydatid disease of the kidney and constituted the subjects of this study. Their age ranged between 20 and 63 years age (mean 40); there were five males and three females. Loin pain was the commonest mode of presentation in these patients. Investigations performed included urine analysis, serological tests, eosinophil count and relevant radiological studies. Urine analysis showed hydatiduria in one patient, the Casoni's test was positive in two, Ghedini skin test was positive in three and eosinophilia was noted in two other patients. All patients were treated surgically using loin supracostal extra-peritoneal approach. Total nephrectomy was performed in five patients, partial nephrectomy in one while excision of the cyst was performed in two patients. Our report suggests that a combination of various investigative modalities with a high index of suspicion is necessary in establishing the correct diagnosis. Surgery remains the main option of treatment for renal hydatid disease.

  1. Longitudinal change in renal function after nephroureterectomy in patients with upper tract urothelial carcinoma

    Directory of Open Access Journals (Sweden)

    Chih-Yuan Chou

    2015-06-01

    Conclusion: In this study, it was found that the average renal function of the patients with upper tract urothelial carcinoma is not as good as the general population. More than half of the normal renal function patients have new onset chronic kidney disease after surgery. For preventing further deterioration of renal function, the implication of partial nephrectomy or segmental ureterectomy for selected patients with localized urothelial carcinoma should be re-examined. Besides, neoadjuvant chemotherapy should be considered for those who are not good candidates for local treatment.

  2. Renal cell carcinoma in patient with crossed fused renal ectopia

    Directory of Open Access Journals (Sweden)

    Ozgur Cakmak

    2016-01-01

    Full Text Available Primary renal cell carcinomas have rarely been reported in patients with crossed fused renal ectopia. We presented a patient with right to left crossed fused kidney harbouring renal tumor. The most frequent tumor encountered in crossed fused renal ectopia is renal cell carcinoma. In this case, partial nephrectomy was performed which pave way to preservation of the uninvolved both renal units. Due to unpredictable anatomy, careful preoperative planning and meticulous delineation of renal vasculature is essential for preservation of the uninvolved renal units.

  3. Photogenic partial seizures.

    Science.gov (United States)

    Hennessy, M J; Binnie, C D

    2000-01-01

    To establish the incidence and symptoms of partial seizures in a cohort of patients investigated on account of known sensitivity to intermittent photic stimulation and/or precipitation of seizures by environmental visual stimuli such as television (TV) screens or computer monitors. We report 43 consecutive patients with epilepsy, who had exhibited a significant EEG photoparoxysmal response or who had seizures precipitated by environmental visual stimuli and underwent detailed assessment of their photosensitivity in the EEG laboratory, during which all were questioned concerning their ictal symptoms. All patients were considered on clinical grounds to have an idiopathic epilepsy syndrome. Twenty-eight (65%) patients reported visually precipitated attacks occurring initially with maintained consciousness, in some instances evolving to a period of confusion or to a secondarily generalized seizure. Visual symptoms were most commonly reported and included positive symptoms such as coloured circles or spots, but also blindness and subjective symptoms such as "eyes going funny." Other symptoms described included nonspecific cephalic sensations, deja-vu, auditory hallucinations, nausea, and vomiting. No patient reported any clear spontaneous partial seizures, and there were no grounds for supposing that any had partial epilepsy excepting the ictal phenomenology of some or all of the visually induced attacks. These findings provide clinical support for the physiological studies that indicate that the trigger mechanism for human photosensitivity involves binocularly innervated cells located in the visual cortex. Thus the visual cortex is the seat of the primary epileptogenic process, and the photically triggered discharges and seizures may be regarded as partial with secondary generalization.

  4. The partial-birth stratagem.

    Science.gov (United States)

    1998-06-01

    In Wisconsin, physicians stopped performing abortions when a Federal District Court Judge refused to issue a temporary restraining order against the state's newly enacted "partial birth" abortion ban that was couched in such vague language it actually covered all abortions. While ostensibly attempting to ban late-term "intact dilation and extraction," the language of the law did not refer to that procedure or to late terms. Instead, it prohibited all abortions in which a physician "partially vaginally delivers a living child, causes the death of the partially delivered child with the intent to kill the child and then completes the delivery of the child." The law also defined "child" as "a human being from the time of fertilization" until birth. It is clear that this abortion ban is unconstitutional under Row v. Wade, and this unconstitutionality is compounded by the fact that the law allowed no exception to protect a woman's health, which is required by Roe for abortion bans after fetal viability. Wisconsin is only one of about 28 states that have enacted similar laws, and only two have restricted the ban to postviability abortions. Many of these laws have been struck down in court, and President Clinton has continued to veto the Federal partial-birth bill. The Wisconsin Judge acknowledged that opponents of the ban will likely prevail when the case is heard, but his action in denying the temporary injunction means that many women in Wisconsin will not receive timely medical care. The partial birth strategy is really only another anti-abortion strategy.

  5. Partially massless fields during inflation

    Science.gov (United States)

    Baumann, Daniel; Goon, Garrett; Lee, Hayden; Pimentel, Guilherme L.

    2018-04-01

    The representation theory of de Sitter space allows for a category of partially massless particles which have no flat space analog, but could have existed during inflation. We study the couplings of these exotic particles to inflationary perturbations and determine the resulting signatures in cosmological correlators. When inflationary perturbations interact through the exchange of these fields, their correlation functions inherit scalings that cannot be mimicked by extra massive fields. We discuss in detail the squeezed limit of the tensor-scalar-scalar bispectrum, and show that certain partially massless fields can violate the tensor consistency relation of single-field inflation. We also consider the collapsed limit of the scalar trispectrum, and find that the exchange of partially massless fields enhances its magnitude, while giving no contribution to the scalar bispectrum. These characteristic signatures provide clean detection channels for partially massless fields during inflation.

  6. The strategic value of partial vertical integration

    OpenAIRE

    Fiocco, Raffaele

    2014-01-01

    We investigate the strategic incentives for partial vertical integration, namely, partial ownership agreements between manufacturers and retailers, when retailers privately know their costs and engage in differentiated good price competition. The partial misalignment between the profit objectives within a partially integrated manufacturer-retailer hierarchy entails a higher retail price than under full integration. This `information vertical effect' translates into an opposite ...

  7. Partial dynamical systems, fell bundles and applications

    CERN Document Server

    Exel, Ruy

    2017-01-01

    Partial dynamical systems, originally developed as a tool to study algebras of operators in Hilbert spaces, has recently become an important branch of algebra. Its most powerful results allow for understanding structural properties of algebras, both in the purely algebraic and in the C*-contexts, in terms of the dynamical properties of certain systems which are often hiding behind algebraic structures. The first indication that the study of an algebra using partial dynamical systems may be helpful is the presence of a grading. While the usual theory of graded algebras often requires gradings to be saturated, the theory of partial dynamical systems is especially well suited to treat nonsaturated graded algebras which are in fact the source of the notion of "partiality". One of the main results of the book states that every graded algebra satisfying suitable conditions may be reconstructed from a partial dynamical system via a process called the partial crossed product. Running in parallel with partial dynamica...

  8. Physics of partially ionized plasmas

    CERN Document Server

    Krishan, Vinod

    2016-01-01

    Plasma is one of the four fundamental states of matter; the other three being solid, liquid and gas. Several components, such as molecular clouds, diffuse interstellar gas, the solar atmosphere, the Earth's ionosphere and laboratory plasmas, including fusion plasmas, constitute the partially ionized plasmas. This book discusses different aspects of partially ionized plasmas including multi-fluid description, equilibrium and types of waves. The discussion goes on to cover the reionization phase of the universe, along with a brief description of high discharge plasmas, tokomak plasmas and laser plasmas. Various elastic and inelastic collisions amongst the three particle species are also presented. In addition, the author demonstrates the novelty of partially ionized plasmas using many examples; for instance, in partially ionized plasma the magnetic induction is subjected to the ambipolar diffusion and the Hall effect, as well as the usual resistive dissipation. Also included is an observation of kinematic dynam...

  9. End Stage and Chronic Kidney Disease: Associations with Renal Cancer

    International Nuclear Information System (INIS)

    Russo, Paul

    2012-01-01

    There is a well known association between end stage renal disease and the development of kidney cancer in the native kidney of patients requiring renal replacement therapy. There is now emerging evidence that lesser degrees of renal insufficiency (chronic kidney disease, CKD) are also associated with an increased likelihood of cancer in general and kidney cancer in particular. Nephropathological changes are commonly observed in the non-tumor bearing portions of kidney resected at the time of partial and radical nephrectomy (RN). In addition, patients with renal cancer are more likely to have CKD at the time of diagnosis and treatment than the general population. The exact mechanism by which renal insufficiency transforms normal kidney cells into tumor cells is not known. Possible mechanisms include uremic immune inhibition or increased exposure to circulating toxins not adequately cleared by the kidneys. Surgeons managing kidney tumors must have an increased awareness of their patient’s renal functional status as they plan their resection. Kidney sparing approaches, including partial nephrectomy (PN) or active surveillance in older and morbidly ill patients, can prevent CKD or delay the further decline in renal function which is well documented with RN. Despite emerging evidence that PN provides equivalent local tumor control to RN while at the same time preventing CKD, this operation remains under utilized in the United States and abroad. Increased awareness of the bi directional relationship between kidney function and kidney cancer is essential in the contemporary management of kidney cancer.

  10. Anatomical Relationship Between the Kidney Collecting System and the Intrarenal Arteries in the Sheep: Contribution for a New Urological Model.

    Science.gov (United States)

    Buys-Gonçalves, Gabriela Faria; De Souza, Diogo Benchimol; Sampaio, Francisco José Barcellos; Pereira-Sampaio, Marco Aurélio

    2016-04-01

    Previous studies have demonstrated that the pig collecting system heals after partial nephrectomy without closure. Recently, a study in sheep showed that partial nephrectomy without closure of the collecting system resulted in urinary leakage and urinoma. The aim of this study was to present detailed anatomical findings on the intrarenal anatomy of the sheep. Forty two kidneys were used to produce tridimensional endocasts of the collecting system together with the intrarenal arteries. A renal pelvis which displayed 11-19 (mean of 16) renal recesses was present. There were no calices present. The renal artery was singular in each kidney and gave two primary branches one to the dorsal surface and one to ventral surface. Dorsal and ventral branches of the renal artery were classified based on the relationship between their branching pattern and the collecting system as: type I (cranial and caudal segmental arteries), type II (cranial, middle and caudal segmental arteries) or type III (cranial, cranial middle, caudal middle, and caudal segmental arteries). Type I was the most common branching pattern for the dorsal and ventral branches of the renal artery. The arterial supply of the caudal pole of the sheep kidney supports its use as an experimental model due to the similarity to the human kidney. However, the lack of a retropelvic artery discourages the use of the cranial pole in experiments in which the arteries are an important aspect to be considered. © 2016 Wiley Periodicals, Inc.

  11. COST ANALYSIS OF LONG ESTABLISHED AND NEWER ORAL ANTIEPILEPTIC DRUGS AVAILABLE IN THE INDIAN MARKET

    Directory of Open Access Journals (Sweden)

    Phatak Abhishek M, Hotwani Jitendra H, Deshmukhkiran R, Panchal Sagar S, Naik Madhura S

    2015-10-01

    Full Text Available Background: Large number of pharmaceutical companies manufactures antiepileptic drugs in India. The price variations among the marketed drugs are wide. Aims: The present study was aimed to find the cost of different oral antiepileptic drugs available in Indian market as monotherapy, combination therapy and number of manufacturing companies for each, to evaluate difference in cost of different brands of same dosage of same active drug by calculating percentage variation of cost. Methods and Materials: Cost of a drug being manufactured by different companies, in the same strength and dosage forms was obtained from “Indian Drug Review” Vol. XXI, Issue No.4, 2014 and “Current Index of Medical Specialties” July-October 2014. The difference in the maximum and minimum price of the same drug manufactured by different pharmaceutical companies and percentage variation in price was calculated. Results: The percentage price variation noted of long-established drugs was – Phenytoin (50mg: 140%, Carbamazepine (100mg: 1033%, Phenobarbital (30mg : 730%, Valproic acid (300mg : 420%. Newer drugs –Levetiracetam (250mg: 75%, Lamotrigine (25mg: 66%, Topiramate (50mg: 108%, Zonisamide (100mg: 19%. Combination drugs – Phenobarbital + Phenytoin (30+100 mg: 354.55%. Conclusion: The percentage price variation of different brands of the same commonly used long-established oral antiepileptic drug manufactured in India is very wide. The formulation or brand of Antiepileptic drugs (AED’s should preferably not be changed since variations in bioavailability or different pharmacokinetic profiles may increase the potential for reduced effect or excessive side effects. Hence, manufacturing companies should aim to decrease the price variation while maintaining the therapeutic efficacy.

  12. Partial Epilepsy with Auditory Features

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2004-07-01

    Full Text Available The clinical characteristics of 53 sporadic (S cases of idiopathic partial epilepsy with auditory features (IPEAF were analyzed and compared to previously reported familial (F cases of autosomal dominant partial epilepsy with auditory features (ADPEAF in a study at the University of Bologna, Italy.

  13. Utilization and perioperative complications of laparoscopic cryoablation vs. robotic partial nephrectomy for localized renal tumors

    Directory of Open Access Journals (Sweden)

    Aaron C. Weinberg

    2015-06-01

    Full Text Available ABSTRACTObjective:To compare the utilization, perioperative complications and predictors of LCA versus RPN in the treatment of localized renal tumors.Methods:From the Nationwide Inpatient Sample we identified patients undergoing RPN or LCA for the treatment of localized renal tumors from October 2008 through 2010. Patient and hospital-specific factors which predict postoperative complications and use of LCA were investigated.Results:14,275 patients with localized renal tumors were identified: 70.3% had RPN and 29.7% had LCA. LCA was more common in older patient and at hospitals without robotic consoles. No difference was identified in perioperative complications (0.2% vs. 0.2%, transfusion (5.1% vs. 6.2%, length of stay (2.9 vs. 3.0 days or median cost ($41,753 vs. $44,618 between the groups, LCA vs. RPN. On multivariate analysis sicker patients were more likely to have LCA (OR 1.34, p=0.048 and sicker patients had greater postoperative complications (OR 3.30, pConclusions:More patients had RPN vs. LCA; surgical technique was not predictive of postoperative complications. As technology develops to treat localized renal tumors, it will be important to continue to track outcomes and costs for procedures including RPN and LCA.

  14. [Removable partial dentures. Oral functions and types

    NARCIS (Netherlands)

    Creugers, N.H.J.; Baat, C. de

    2009-01-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic

  15. Beginning partial differential equations

    CERN Document Server

    O'Neil, Peter V

    2014-01-01

    A broad introduction to PDEs with an emphasis on specialized topics and applications occurring in a variety of fields Featuring a thoroughly revised presentation of topics, Beginning Partial Differential Equations, Third Edition provides a challenging, yet accessible,combination of techniques, applications, and introductory theory on the subjectof partial differential equations. The new edition offers nonstandard coverageon material including Burger's equation, the telegraph equation, damped wavemotion, and the use of characteristics to solve nonhomogeneous problems. The Third Edition is or

  16. [Acrylic resin removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of

  17. PARALLEL SOLUTION METHODS OF PARTIAL DIFFERENTIAL EQUATIONS

    Directory of Open Access Journals (Sweden)

    Korhan KARABULUT

    1998-03-01

    Full Text Available Partial differential equations arise in almost all fields of science and engineering. Computer time spent in solving partial differential equations is much more than that of in any other problem class. For this reason, partial differential equations are suitable to be solved on parallel computers that offer great computation power. In this study, parallel solution to partial differential equations with Jacobi, Gauss-Siedel, SOR (Succesive OverRelaxation and SSOR (Symmetric SOR algorithms is studied.

  18. Partial processing

    International Nuclear Information System (INIS)

    1978-11-01

    This discussion paper considers the possibility of applying to the recycle of plutonium in thermal reactors a particular method of partial processing based on the PUREX process but named CIVEX to emphasise the differences. The CIVEX process is based primarily on the retention of short-lived fission products. The paper suggests: (1) the recycle of fission products with uranium and plutonium in thermal reactor fuel would be technically feasible; (2) it would, however, take ten years or more to develop the CIVEX process to the point where it could be launched on a commercial scale; (3) since the majority of spent fuel to be reprocessed this century will have been in storage for ten years or more, the recycling of short-lived fission products with the U-Pu would not provide an effective means of making refabrication fuel ''inaccessible'' because the radioactivity associated with the fission products would have decayed. There would therefore be no advantage in partial processing

  19. Development of Partial Discharging Simulation Test Equipment

    Science.gov (United States)

    Kai, Xue; Genghua, Liu; Yan, Jia; Ziqi, Chai; Jian, Lu

    2017-12-01

    In the case of partial discharge training for recruits who lack of on-site work experience, the risk of physical shock and damage of the test equipment may be due to the limited skill level and improper operation by new recruits. Partial discharge simulation tester is the use of simulation technology to achieve partial discharge test process simulation, relatively true reproduction of the local discharge process and results, so that the operator in the classroom will be able to get familiar with and understand the use of the test process and equipment.The teacher sets up the instrument to display different partial discharge waveforms so that the trainees can analyze the test results of different partial discharge types.

  20. PARTIAL TRISOMY 4p AND PARTIAL MONOSOMY 13q: CASE REPORT AND A LITERATURE REVIEW.

    Science.gov (United States)

    Puvabanditsin, S; Herrera-Garcia, G; Gengel, N; Hussein, K; February, M; Mayne, J; Mehta, R

    2016-01-01

    We report on a term first born dichorionic-diamniotic twin with deletion of the distal long arm of chromosome 13, partial trisomy of the short arm of chromosome 4, intrauterine growth retardation, and multiple anomalies including microcephaly, colpocephaly, absent corpus callosum, bulbous tip of the nose, large and low set ears, macroglossia, thin upper lip, double outlet right ventricle, atria/ventricular septal defect, cleft mitral valve, pulmonary stenosis, single umbilical artery, multicystic dysplastic left kidney, sacral dimple, anterior displacement of anus, simian creases, abnormal thumb (congenital clasped thumb), overlapping toes, and congenital hypothyroidism. This is the first report of a patient with partial trisomy 4p and partial monosomy 13q.

  1. Partial Cancellation

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Partial Cancellation. Full Cancellation is desirable. But complexity requirements are enormous. 4000 tones, 100 Users billions of flops !!! Main Idea: Challenge: To determine which cross-talker to cancel on what “tone” for a given victim. Constraint: Total complexity is ...

  2. Partial molar volumes and partial molar adiabatic compressibilities of a short chain perfluorosurfactant: Sodium heptafluorobutyrate in aqueous solutions at different temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Blanco, Elena [Group of Biophysics and Interfaces, Department of Applied Physics, Faculty of Physics, University of Santiago de Compostela, E-15782 Santiago de Compostela (Spain); Ruso, Juan M. [Group of Biophysics and Interfaces, Department of Applied Physics, Faculty of Physics, University of Santiago de Compostela, E-15782 Santiago de Compostela (Spain)]. E-mail: faruso@usc.es; Prieto, Gerardo [Group of Biophysics and Interfaces, Department of Applied Physics, Faculty of Physics, University of Santiago de Compostela, E-15782 Santiago de Compostela (Spain); Sarmiento, Felix [Group of Biophysics and Interfaces, Department of Applied Physics, Faculty of Physics, University of Santiago de Compostela, E-15782 Santiago de Compostela (Spain)

    2005-12-15

    Density and ultrasound measurements of sodium heptafluorobutyrate in aqueous solutions at T = (283.15, 288.15, 293.15, 298.15, 303.15, 308.15, 313.15, 318.15, and 323.15) K have been obtained. From these results partial molar volumes and isentropic partial molar adiabatic compressibilities were calculated. Deviations from the Debye-Hueckel limiting law provide evidence for limited association at lower concentrations. The change of the partial molar volume and isentropic partial molar adiabatic compressibility upon aggregation was calculated. Variations of the change of partial molar volumes and isentropic partial molar adiabatic compressibility upon aggregation are discussed in terms of temperature.

  3. Partial molar volumes and partial molar adiabatic compressibilities of a short chain perfluorosurfactant: Sodium heptafluorobutyrate in aqueous solutions at different temperatures

    International Nuclear Information System (INIS)

    Blanco, Elena; Ruso, Juan M.; Prieto, Gerardo; Sarmiento, Felix

    2005-01-01

    Density and ultrasound measurements of sodium heptafluorobutyrate in aqueous solutions at T = (283.15, 288.15, 293.15, 298.15, 303.15, 308.15, 313.15, 318.15, and 323.15) K have been obtained. From these results partial molar volumes and isentropic partial molar adiabatic compressibilities were calculated. Deviations from the Debye-Hueckel limiting law provide evidence for limited association at lower concentrations. The change of the partial molar volume and isentropic partial molar adiabatic compressibility upon aggregation was calculated. Variations of the change of partial molar volumes and isentropic partial molar adiabatic compressibility upon aggregation are discussed in terms of temperature

  4. Partial vaginismus : definition, symptoms and treatment

    OpenAIRE

    Engman, Maria

    2007-01-01

    Vaginismus is a sexual pain disorder, where spasm of musculature of the outer third of the vagina interferes with intercourse. Vaginismus exists in two forms: total vaginismus, where intercourse is impossible, and the more seldom described partial vaginismus, in which intercourse is possible but painful. The aim of the thesis was to develop a useful definition of partial vaginismus for both clinical and scientific purposes; to describe the prevalence of partial vaginismus among women with sup...

  5. Abstract methods in partial differential equations

    CERN Document Server

    Carroll, Robert W

    2012-01-01

    Detailed, self-contained treatment examines modern abstract methods in partial differential equations, especially abstract evolution equations. Suitable for graduate students with some previous exposure to classical partial differential equations. 1969 edition.

  6. Partially molten magma ocean model

    International Nuclear Information System (INIS)

    Shirley, D.N.

    1983-01-01

    The properties of the lunar crust and upper mantle can be explained if the outer 300-400 km of the moon was initially only partially molten rather than fully molten. The top of the partially molten region contained about 20% melt and decreased to 0% at 300-400 km depth. Nuclei of anorthositic crust formed over localized bodies of magma segregated from the partial melt, then grew peripherally until they coverd the moon. Throughout most of its growth period the anorthosite crust floated on a layer of magma a few km thick. The thickness of this layer is regulated by the opposing forces of loss of material by fractional crystallization and addition of magma from the partial melt below. Concentrations of Sr, Eu, and Sm in pristine ferroan anorthosites are found to be consistent with this model, as are trends for the ferroan anorthosites and Mg-rich suites on a diagram of An in plagioclase vs. mg in mafics. Clustering of Eu, Sr, and mg values found among pristine ferroan anorthosites are predicted by this model

  7. Optimal partial-arcs in VMAT treatment planning

    International Nuclear Information System (INIS)

    Wala, Jeremiah; Salari, Ehsan; Chen Wei; Craft, David

    2012-01-01

    We present a method for improving the delivery efficiency of VMAT by extending the recently published VMAT treatment planning algorithm vmerge to automatically generate optimal partial-arc plans. A high-quality initial plan is created by solving a convex multicriteria optimization problem using 180 equi-spaced beams. This initial plan is used to form a set of dose constraints, and a set of partial-arc plans is created by searching the space of all possible partial-arc plans that satisfy these constraints. For each partial-arc, an iterative fluence map merging and sequencing algorithm (vmerge) is used to improve the delivery efficiency. Merging continues as long as the dose quality is maintained above a user-defined threshold. The final plan is selected as the partial-arc with the lowest treatment time. The complete algorithm is called pmerge. Partial-arc plans are created using pmerge for a lung, liver and prostate case, with final treatment times of 127, 245 and 147 s. Treatment times using full arcs with vmerge are 211, 357 and 178 s. The mean doses to the critical structures for the vmerge and pmerge plans are kept within 5% of those in the initial plan, and the target volume covered by the prescription isodose is maintained above 98% for the pmerge and vmerge plans. Additionally, we find that the angular distribution of fluence in the initial plans is predictive of the start and end angles of the optimal partial-arc. We conclude that VMAT delivery efficiency can be improved by employing partial-arcs without compromising dose quality, and that partial-arcs are most applicable to cases with non-centralized targets. (paper)

  8. Partial differential equations of mathematical physics

    CERN Document Server

    Sobolev, S L

    1964-01-01

    Partial Differential Equations of Mathematical Physics emphasizes the study of second-order partial differential equations of mathematical physics, which is deemed as the foundation of investigations into waves, heat conduction, hydrodynamics, and other physical problems. The book discusses in detail a wide spectrum of topics related to partial differential equations, such as the theories of sets and of Lebesgue integration, integral equations, Green's function, and the proof of the Fourier method. Theoretical physicists, experimental physicists, mathematicians engaged in pure and applied math

  9. Partial Evaluation of the Euclidian Algorithm

    DEFF Research Database (Denmark)

    Danvy, Olivier; Goldberg, Mayer

    1997-01-01

    -like behavior. Each of them presents a challenge for partial evaluation. The Euclidian algorithm is one of them, and in this article, we make it amenable to partial evaluation. We observe that the number of iterations in the Euclidian algorithm is bounded by a number that can be computed given either of the two...... arguments. We thus rephrase this algorithm using bounded recursion. The resulting program is better suited for automatic unfolding and thus for partial evaluation. Its specialization is efficient....

  10. Parachute technique for partial penectomy

    Directory of Open Access Journals (Sweden)

    Fernando Korkes

    2010-04-01

    Full Text Available PURPOSE: Penile carcinoma is a rare but mutilating malignancy. In this context, partial penectomy is the most commonly applied approach for best oncological results. We herein propose a simple modification of the classic technique of partial penectomy, for better cosmetic and functional results. TECHNIQUE: If partial penectomy is indicated, the present technique can bring additional benefits. Different from classical technique, the urethra is spatulated only ventrally. An inverted "V" skin flap with 0.5 cm of extension is sectioned ventrally. The suture is performed with vicryl 4-0 in a "parachute" fashion, beginning from the ventral portion of the urethra and the "V" flap, followed by the "V" flap angles and than by the dorsal portion of the penis. After completion of the suture, a Foley catheter and light dressing are placed for 24 hours. CONCLUSIONS: Several complex reconstructive techniques have been previously proposed, but normally require specific surgical abilities, adequate patient selection and staged procedures. We believe that these reconstructive techniques are very useful in some specific subsets of patients. However, the technique herein proposed is a simple alternative that can be applied to all men after a partial penectomy, and takes the same amount of time as that in the classic technique. In conclusion, the "parachute" technique for penile reconstruction after partial amputation not only improves the appearance of the penis, but also maintains an adequate function.

  11. Partial rectangular metric spaces and fixed point theorems.

    Science.gov (United States)

    Shukla, Satish

    2014-01-01

    The purpose of this paper is to introduce the concept of partial rectangular metric spaces as a generalization of rectangular metric and partial metric spaces. Some properties of partial rectangular metric spaces and some fixed point results for quasitype contraction in partial rectangular metric spaces are proved. Some examples are given to illustrate the observed results.

  12. Numerical Analysis of Partial Differential Equations

    CERN Document Server

    Lui, S H

    2011-01-01

    A balanced guide to the essential techniques for solving elliptic partial differential equations Numerical Analysis of Partial Differential Equations provides a comprehensive, self-contained treatment of the quantitative methods used to solve elliptic partial differential equations (PDEs), with a focus on the efficiency as well as the error of the presented methods. The author utilizes coverage of theoretical PDEs, along with the nu merical solution of linear systems and various examples and exercises, to supply readers with an introduction to the essential concepts in the numerical analysis

  13. Partial Transposition on Bipartite System

    International Nuclear Information System (INIS)

    Xi-Jun, Ren; Yong-Jian, Han; Yu-Chun, Wu; Guang-Can, Guo

    2008-01-01

    Many properties of partial transposition are unclear as yet. Here we carefully consider the number of the negative eigenvalues of ρ T (ρ's partial transposition) when ρ is a two-partite state. There is strong evidence to show that the number of negative eigenvalues of ρ T is N(N − 1)/2 at most when ρ is a state in Hilbert space C N C N . For the special case, the 2 × 2 system, we use this result to give a partial proof of the conjecture |ρ T | T ≥ 0. We find that this conjecture is strongly connected with the entanglement of the state corresponding to the negative eigenvalue of ρ T or the negative entropy of ρ

  14. Linear algebraic theory of partial coherence: discrete fields and measures of partial coherence.

    Science.gov (United States)

    Ozaktas, Haldun M; Yüksel, Serdar; Kutay, M Alper

    2002-08-01

    A linear algebraic theory of partial coherence is presented that allows precise mathematical definitions of concepts such as coherence and incoherence. This not only provides new perspectives and insights but also allows us to employ the conceptual and algebraic tools of linear algebra in applications. We define several scalar measures of the degree of partial coherence of an optical field that are zero for full incoherence and unity for full coherence. The mathematical definitions are related to our physical understanding of the corresponding concepts by considering them in the context of Young's experiment.

  15. Hierarchical partial order ranking

    International Nuclear Information System (INIS)

    Carlsen, Lars

    2008-01-01

    Assessing the potential impact on environmental and human health from the production and use of chemicals or from polluted sites involves a multi-criteria evaluation scheme. A priori several parameters are to address, e.g., production tonnage, specific release scenarios, geographical and site-specific factors in addition to various substance dependent parameters. Further socio-economic factors may be taken into consideration. The number of parameters to be included may well appear to be prohibitive for developing a sensible model. The study introduces hierarchical partial order ranking (HPOR) that remedies this problem. By HPOR the original parameters are initially grouped based on their mutual connection and a set of meta-descriptors is derived representing the ranking corresponding to the single groups of descriptors, respectively. A second partial order ranking is carried out based on the meta-descriptors, the final ranking being disclosed though average ranks. An illustrative example on the prioritisation of polluted sites is given. - Hierarchical partial order ranking of polluted sites has been developed for prioritization based on a large number of parameters

  16. On Degenerate Partial Differential Equations

    OpenAIRE

    Chen, Gui-Qiang G.

    2010-01-01

    Some of recent developments, including recent results, ideas, techniques, and approaches, in the study of degenerate partial differential equations are surveyed and analyzed. Several examples of nonlinear degenerate, even mixed, partial differential equations, are presented, which arise naturally in some longstanding, fundamental problems in fluid mechanics and differential geometry. The solution to these fundamental problems greatly requires a deep understanding of nonlinear degenerate parti...

  17. Introduction to partial differential equations

    CERN Document Server

    Greenspan, Donald

    2000-01-01

    Designed for use in a one-semester course by seniors and beginning graduate students, this rigorous presentation explores practical methods of solving differential equations, plus the unifying theory underlying the mathematical superstructure. Topics include basic concepts, Fourier series, second-order partial differential equations, wave equation, potential equation, heat equation, approximate solution of partial differential equations, and more. Exercises appear at the ends of most chapters. 1961 edition.

  18. Arthroscopic partial medial meniscectomy

    Directory of Open Access Journals (Sweden)

    Dašić Žarko

    2011-01-01

    Full Text Available Background/Aim. Meniscal injuries are common in professional or recreational sports as well as in daily activities. If meniscal lesions lead to physical impairment they usually require surgical treatment. Arthroscopic treatment of meniscal injuries is one of the most often performed orthopedic operative procedures. Methods. The study analyzed the results of arthroscopic partial medial meniscectomy in 213 patients in a 24-month period, from 2006, to 2008. Results. In our series of arthroscopically treated medial meniscus tears we noted 78 (36.62% vertical complete bucket handle lesions, 19 (8.92% vertical incomplete lesions, 18 (8.45% longitudinal tears, 35 (16.43% oblique tears, 18 (8.45% complex degenerative lesions, 17 (7.98% radial lesions and 28 (13.14% horisontal lesions. Mean preoperative International Knee Documentation Committee (IKDC score was 49.81%, 1 month after the arthroscopic partial medial meniscectomy the mean IKDC score was 84.08%, and 6 months after mean IKDC score was 90.36%. Six months after the procedure 197 (92.49% of patients had good or excellent subjective postoperative clinical outcomes, while 14 (6.57% patients subjectively did not notice a significant improvement after the intervention, and 2 (0.93% patients had no subjective improvement after the partial medial meniscectomy at all. Conclusion. Arthroscopic partial medial meniscetomy is minimally invasive diagnostic and therapeutic procedure and in well selected cases is a method of choice for treatment of medial meniscus injuries when repair techniques are not a viable option. It has small rate of complications, low morbidity and fast rehabilitation.

  19. Economical analysis of the second partial reload for Angra 1 with partial low-leakage

    International Nuclear Information System (INIS)

    Mascarenhas, H.A.; Teixeira, M.C.C.; Dias, A.M.

    1990-01-01

    Preliminary results for the Angra 1 second reload design with partial low-leakage were assessed with NUCOST 1.0, code for nuclear power costs calculation. In the proposed scheme, some partially burned fuel assemblies (FAs) are located at the core boundary, while new FAs occupy more internal positions. The nuclear design - utilizing the code system SAV (from Siemens/KWU Group, F.R. Germany) - has been performed with detail for the 3rd cycle while simpler approach has been utilized for subsequent reloads. Results of NUCOST 1.0 show that the partial low-leakage reload in the 3rd cycle of Angra 1 offers fuel costs 1% lower when compared to the Plant's actual reload scheme, what corresponds to an savings of about US$190.000. When operation and maintenance and capital costs are also considered, economies in the order of US$2.6 million are obrained. (author) [pt

  20. Partial Safety Factors for Rubble Mound Breakwaters

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Burcharth, H. F.; Christiani, E.

    1995-01-01

    On the basis of the failure modes formulated in the various subtasks calibration of partial safety factors are described in this paper. The partial safety factors can be used to design breakwaters under quite different design conditions, namely probabilities of failure from 0.01 to 0.4, design...... lifetimes from 20 to 100 years and different qualities of wave data. A code of practice where safety is taken into account using partial safety factors is called a level I code. The partial safety factors are calibrated using First Order Reliability Methods (FORM, see Madsen et al. [1]) where...... in section 3. First Order Reliability Methods are described in section 4, and in section 5 it is shown how partial safety factors can be introduced and calibrated. The format of a code for design and analysis of rubble mound breakwaters is discussed in section 6. The mathematical formulation of the limit...