WorldWideScience

Sample records for partial molar heats

  1. Standard partial molar heat capacities and enthalpies of formation of aqueous aluminate under hydrothermal conditions from integral heat of solution measurements

    International Nuclear Information System (INIS)

    Coulier, Yohann; Tremaine, Peter R.

    2014-01-01

    Highlights: • Heats of solution of NaAlO 2 (s) were measured at five temperatures up to 250 °C. • Standard molar enthalpies of solution were determined from the measured heats of solution. • Standard molar enthalpies of solution were correlated with the density model. • The density model allows us to determine the standard molar heat capacities of reaction. - Abstract: Heats of solution of sodium aluminum oxide, NaAlO 2 (s), were measured in aqueous sodium hydroxide solutions using a Tian–Calvet heat-flow calorimeter (Setaram, Model C80) with high pressure “batch cells” made of hastelloy C-276, at five temperatures from (373.15 to 523.15) K, steam saturation pressure, and concentrations from (0.02 to 0.09) mol · kg −1 . Standard molar enthalpies of solution, Δ soln H ∘ , and relative standard molar enthalpies, [H ∘ (T) − H ∘ (298.15 K)], of NaAl(OH) 4 (aq) were determined from the measured heats of solution. The results were fitted with the “density” model. The temperature dependence of Δ soln H ∘ from the model yielded the standard molar heat capacities of reaction, Δ soln C p ∘ , from which standard partial molar heat capacities for aqueous aluminate, C p ∘ [A1(OH) 4 − ,aq], were calculated. Standard partial molar enthalpies of formation, Δ f H ∘ , and entropies, S ∘ , of A1(OH) 4 − (aq) were also determined. The values for C p ∘ [A1(OH) 4 − ,aq] agree with literature data determined up to T = 413 K from enthalpy of solution and heat capacity measurements to within the combined experimental uncertainties. They are consistent with differential heat capacity measurements up to T = 573 K from Schrödle et al. (2010) [29] using the same calorimeter, but this method has the advantage that measurements could be made at much lower concentrations in the presence of an excess concentration of ligand. To our knowledge, these are the first standard partial molar heat capacities measured under hydrothermal conditions by the

  2. The partial molar heat capacity, expansion, isentropic, and isothermal compressions of thymidine in aqueous solution at T = 298.15 K

    International Nuclear Information System (INIS)

    Hedwig, Gavin R.; Jameson, Geoffrey B.; Hoiland, Harald

    2011-01-01

    Highlights: → Solution densities and sound speeds were measured for aqueous solutions of thymidine. → Partial molar volumetric properties at infinite dilution and T = 298.15 K were derived. → The partial molar isentropic and isothermal compressions are of opposite signs. → The partial molar heat capacity for thymidine at infinite dilution was determined. - Abstract: Solution densities have been determined for aqueous solutions of thymidine at T = (288.15, 298.15, 303.15, and 313.15) K. The partial molar volumes at infinite dilution, V 2 0 , obtained from the density data were used to derive the partial molar isobaric expansion at infinite dilution for thymidine at T = 298.15 K, E 2 0 {E 2 0 =(∂V 2 0 /∂T) p }. The partial molar heat capacity at infinite dilution for thymidine, C p,2 0 , at T = 298.15 K has also been determined. Sound speeds have been measured for aqueous solutions of thymidine at T = 298.15 K. The partial molar isentropic compression at infinite dilution, K S,2 0 , and the partial molar isothermal compression at infinite dilution, K T,2 0 {K T,2 0 =-(∂V 2 0 /∂P) T }, have been derived from the sound speed data. The V 2 0 , E 2 0 , C p,2 0 , and K S,2 0 results for thymidine are critically compared with those available from the literature.

  3. Aqueous partial molar heat capacities and volumes for NaReO4 and NaTcO4

    International Nuclear Information System (INIS)

    Lemire, R.J.; Saluja, P.P.S.; Campbell, A.B.

    1989-01-01

    As part of the Canadian Nuclear Fuel Waste Management Program, data are required to model the equilibrium thermodynamic behavior of key radionuclides at temperatures above 25 degree C. A flow microcalorimeter/densimeter system has been commissioned to measure heat capacities and densities of solutions containing radioactive species. Measurements for solutions of aqueous NaReO 4 (a common analogue for NaTcO 4 ) were made at seven temperatures (15 to 100 degree C) over the concentration range 0.05 to 0.2 mol·kg -1 . Subsequently, measurements were made for NaTcO 4 solutions under similar conditions. The heat capacity and density data are analyzed using Pitzer's ion-interaction model, and values of the NaReO 4 partial molar heat capacities are compared to literature values based on integral heats of solution. The agreement between the two sets of NaReO 4 data is good below 75 degree C, but only fair at the higher temperatures. Values of the partial molar volumes have also been derived. The uncertainties introduced by using thermodynamic data for ReO 4 - , in the absence of data for TcO 4 - , are discussed

  4. Partial molar volumes and partial molar adiabatic compressibilities of a short chain perfluorosurfactant: Sodium heptafluorobutyrate in aqueous solutions at different temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Blanco, Elena [Group of Biophysics and Interfaces, Department of Applied Physics, Faculty of Physics, University of Santiago de Compostela, E-15782 Santiago de Compostela (Spain); Ruso, Juan M. [Group of Biophysics and Interfaces, Department of Applied Physics, Faculty of Physics, University of Santiago de Compostela, E-15782 Santiago de Compostela (Spain)]. E-mail: faruso@usc.es; Prieto, Gerardo [Group of Biophysics and Interfaces, Department of Applied Physics, Faculty of Physics, University of Santiago de Compostela, E-15782 Santiago de Compostela (Spain); Sarmiento, Felix [Group of Biophysics and Interfaces, Department of Applied Physics, Faculty of Physics, University of Santiago de Compostela, E-15782 Santiago de Compostela (Spain)

    2005-12-15

    Density and ultrasound measurements of sodium heptafluorobutyrate in aqueous solutions at T = (283.15, 288.15, 293.15, 298.15, 303.15, 308.15, 313.15, 318.15, and 323.15) K have been obtained. From these results partial molar volumes and isentropic partial molar adiabatic compressibilities were calculated. Deviations from the Debye-Hueckel limiting law provide evidence for limited association at lower concentrations. The change of the partial molar volume and isentropic partial molar adiabatic compressibility upon aggregation was calculated. Variations of the change of partial molar volumes and isentropic partial molar adiabatic compressibility upon aggregation are discussed in terms of temperature.

  5. Partial molar volumes and partial molar adiabatic compressibilities of a short chain perfluorosurfactant: Sodium heptafluorobutyrate in aqueous solutions at different temperatures

    International Nuclear Information System (INIS)

    Blanco, Elena; Ruso, Juan M.; Prieto, Gerardo; Sarmiento, Felix

    2005-01-01

    Density and ultrasound measurements of sodium heptafluorobutyrate in aqueous solutions at T = (283.15, 288.15, 293.15, 298.15, 303.15, 308.15, 313.15, 318.15, and 323.15) K have been obtained. From these results partial molar volumes and isentropic partial molar adiabatic compressibilities were calculated. Deviations from the Debye-Hueckel limiting law provide evidence for limited association at lower concentrations. The change of the partial molar volume and isentropic partial molar adiabatic compressibility upon aggregation was calculated. Variations of the change of partial molar volumes and isentropic partial molar adiabatic compressibility upon aggregation are discussed in terms of temperature

  6. Dilatometric measurement of the partial molar volume of water sorbed to durum wheat flour.

    Science.gov (United States)

    Hasegawa, Ayako; Ogawa, Takenobu; Adachi, Shuji

    2013-01-01

    Moisture sorption isotherms were measured at 25 °C for untreated, dry-heated and pre-gelatinized durum wheat flour samples. The isotherms could be expressed by the Guggenheim-Anderson-de Boer equation. The amount of water sorbed to the untreated flour was highest for low water activity, with water sorbed to the pre-gelatinized and dry-heated flour samples following. The dry-heated and pregelatinized flour samples exhibited the same dependence of the moisture content on the partial molar volume of water at 25 °C as the untreated flour. The partial molar volume of water was ca. 9 cm(3)/mol at a moisture content of 0.03 kg-H2O/kg-d.m. The volume increased with increasing moisture content, and reached a constant value of ca. 17.5 cm(3)/mol at a moisture content of 0.2 kg-H2O/kg-d.m. or higher.

  7. Apparent and standard partial molar heat capacities and volumes of aqueous tartaric acid and its sodium salts at elevated temperature and pressure

    International Nuclear Information System (INIS)

    Xie Wei; Trevani, Liliana; Tremaine, Peter R.

    2004-01-01

    Apparent molar heat capacities and volumes have been determined for aqueous solutions of tartaric acid (H 2 Tar, Tar=C 4 H 4 O 6 ), two buffer solutions of (H 2 Tar/NaHTar) and (NaHTar/Na 2 Tar), and solutions of disodium tartrate (Na 2 Tar) at four temperatures in the range 283.15≤T/K≤328.15 at p=1 MPa. Apparent molar volumes for H 2 Tar(aq) and Na 2 Tar(aq) have been measured at temperatures 377.15≤T/K≤529.15 and p=10.4 MPa. The experimental results have been represented with a model to describe the molality and temperature dependence. Extrapolations to infinite dilution yielded standard partial molar heat capacities C p 0 and volumes V 0 for the species H 2 Tar(aq), HTar - (aq) and Tar 2- (aq) over the range of experimental measurements. The temperature dependence of V 0 for Na 2 Tar(aq) is consistent with other aqueous electrolytes, while that of H 2 Tar(aq) may be anomalous, in that it does not show divergence towards increasingly positive values with increasing temperature

  8. The Component Slope Linear Model for Calculating Intensive Partial Molar Properties: Application to Waste Glasses

    International Nuclear Information System (INIS)

    Reynolds, Jacob G.

    2013-01-01

    Partial molar properties are the changes occurring when the fraction of one component is varied while the fractions of all other component mole fractions change proportionally. They have many practical and theoretical applications in chemical thermodynamics. Partial molar properties of chemical mixtures are difficult to measure because the component mole fractions must sum to one, so a change in fraction of one component must be offset with a change in one or more other components. Given that more than one component fraction is changing at a time, it is difficult to assign a change in measured response to a change in a single component. In this study, the Component Slope Linear Model (CSLM), a model previously published in the statistics literature, is shown to have coefficients that correspond to the intensive partial molar properties. If a measured property is plotted against the mole fraction of a component while keeping the proportions of all other components constant, the slope at any given point on a graph of this curve is the partial molar property for that constituent. Actually plotting this graph has been used to determine partial molar properties for many years. The CSLM directly includes this slope in a model that predicts properties as a function of the component mole fractions. This model is demonstrated by applying it to the constant pressure heat capacity data from the NaOH-NaAl(OH 4 H 2 O system, a system that simplifies Hanford nuclear waste. The partial molar properties of H 2 O, NaOH, and NaAl(OH) 4 are determined. The equivalence of the CSLM and the graphical method is verified by comparing results detennined by the two methods. The CSLM model has been previously used to predict the liquidus temperature of spinel crystals precipitated from Hanford waste glass. Those model coefficients are re-interpreted here as the partial molar spinel liquidus temperature of the glass components

  9. The partial molar volume of BeSO4 in aqueous solutions

    International Nuclear Information System (INIS)

    Kuschel, F.; Seidel, J.

    1981-01-01

    The density of aqueous solutions of BeSO 4 has been measured as a function of the mole fraction in the range of 0.02487 x 10 -2 to 6.3082 x 10 -2 . From the results obtained the molar volume and partial molar volume have been calculated and the limiting value of the partial molar volume for Be 2+ was extrapolated in accordance with the Debye-Hueckel law

  10. Parsing partial molar volumes of small molecules: a molecular dynamics study.

    Science.gov (United States)

    Patel, Nisha; Dubins, David N; Pomès, Régis; Chalikian, Tigran V

    2011-04-28

    We used molecular dynamics (MD) simulations in conjunction with the Kirkwood-Buff theory to compute the partial molar volumes for a number of small solutes of various chemical natures. We repeated our computations using modified pair potentials, first, in the absence of the Coulombic term and, second, in the absence of the Coulombic and the attractive Lennard-Jones terms. Comparison of our results with experimental data and the volumetric results of Monte Carlo simulation with hard sphere potentials and scaled particle theory-based computations led us to conclude that, for small solutes, the partial molar volume computed with the Lennard-Jones potential in the absence of the Coulombic term nearly coincides with the cavity volume. On the other hand, MD simulations carried out with the pair interaction potentials containing only the repulsive Lennard-Jones term produce unrealistically large partial molar volumes of solutes that are close to their excluded volumes. Our simulation results are in good agreement with the reported schemes for parsing partial molar volume data on small solutes. In particular, our determined interaction volumes() and the thickness of the thermal volume for individual compounds are in good agreement with empirical estimates. This work is the first computational study that supports and lends credence to the practical algorithms of parsing partial molar volume data that are currently in use for molecular interpretations of volumetric data.

  11. Thermodynamic interrelation between excess limiting partial molar characteristics of a liquid nonelectrolyte

    International Nuclear Information System (INIS)

    Ivanov, Evgeniy V.

    2012-01-01

    Highlights: ► Excess limiting molar volume may be regarded as a solvation-related characteristic. ► Volumetric and enthalpic effects of dissolution are interrelated thermodynamically. ► Possibility to estimate the partial change in solute compressibility is described. - Abstract: On the basis of thermodynamic analysis, it is concluded that the excess limiting partial molar volume, like the excess limiting partial molar enthalpy, can be considered as a solvation-related characteristic of a liquid nonelectrolyte. A thermodynamically grounded interrelation between standard volumetric and enthalpic effects of solution of a liquid nonelectrolyte (or series of nonelectrolytes) is suggested.

  12. Excess molar volumes and partial molar volumes for (propionitrile + an alkanol) at T = 298.15 K and p = 0.1 MPa

    International Nuclear Information System (INIS)

    Deenadayalu, N.; Bhujrajh, P.

    2006-01-01

    The excess molar volumes and the partial molar volumes for (propionitrile + an alkanol) at T = 298.15 K and at atmospheric pressure are reported. The hydrogen bonding between the OH133;NC groups are discussed in terms of the chain length of the alkanol. The alkanols studied are (methanol, ethanol, 1-propanol, 2-propanol, 1-butanol, and 1-pentanol). The excess molar volume data was fitted to the Redlich-Kister equation The partial molar volumes were calculated from the Redlich-Kister coefficients

  13. Partial molar volumes of proteins: amino acid side-chain contributions derived from the partial molar volumes of some tripeptides over the temperature range 10-90 degrees C.

    Science.gov (United States)

    Häckel, M; Hinz, H J; Hedwig, G R

    1999-11-15

    The partial molar volumes of tripeptides of sequence glycyl-X-glycine, where X is one of the amino acids alanine, leucine, threonine, glutamine, phenylalanine, histidine, cysteine, proline, glutamic acid, and arginine, have been determined in aqueous solution over the temperature range 10-90 degrees C using differential scanning densitometry . These data, together with those reported previously, have been used to derive the partial molar volumes of the side-chains of all 20 amino acids. The side-chain volumes are critically compared with literature values derived using partial molar volumes for alternative model compounds. The new amino acid side-chain volumes, along with that for the backbone glycyl group, were used to calculate the partial specific volumes of several proteins in aqueous solution. The results obtained are compared with those observed experimentally. The new side-chain volumes have also been used to re-determine residue volume changes upon protein folding.

  14. Apparent and standard molar volumes and heat capacities of aqueous Ni(ClO4)2 from 25 to 85oC

    International Nuclear Information System (INIS)

    Pan, P.; Campbell, A.B.

    1997-01-01

    Apparent molar heat capacities and volumes of aqueous Ni(ClO 4 ) 2 were measured from 25 to 85 o C over a concentration range of 0.02 to 0.8 mol-kg -1 using a Picker flow microcalorimeter and a Picker vibrating-tube densimeter. An extended Debye-Huckel equation was fitted to the experimental data to obtain expressions for the apparent molar properties as functions of ionic strength for Ni(ClO 4 ) 2 (aq). The standard-state partial molar properties for Ni(ClO 4 ) 2 (aq) in the temperature range 25 to 85 o C were obtained and can be expressed by empirical equations. The standard partial molar heat capacities and volumes for Ni 2+ (aq) from 25 to 86 o C were obtained by using the additivity rule and data for ClO - 4 (aq) in the literature. These values were extrapolated to 300 o C by employing the Helgeson-Kirkham-Flower (HKF) equations, amended to include a standard-state correction term. (author)

  15. Partial Molar Volumes of Aqua Ions from First Principles.

    Science.gov (United States)

    Wiktor, Julia; Bruneval, Fabien; Pasquarello, Alfredo

    2017-08-08

    Partial molar volumes of ions in water solution are calculated through pressures obtained from ab initio molecular dynamics simulations. The correct definition of pressure in charged systems subject to periodic boundary conditions requires access to the variation of the electrostatic potential upon a change of volume. We develop a scheme for calculating such a variation in liquid systems by setting up an interface between regions of different density. This also allows us to determine the absolute deformation potentials for the band edges of liquid water. With the properly defined pressures, we obtain partial molar volumes of a series of aqua ions in very good agreement with experimental values.

  16. Partial molar volumes of hydrogen and deuterium in niobium and vanadium

    International Nuclear Information System (INIS)

    Herro, H.M.

    1979-01-01

    Lattice dilation studies and direct pressure experiments gave comparable values for the partial molar volumes of hydrogen and deuterium in niobium and vanadium. Small isotope effects in the partial molar volume of hydrogen were measured in both metals by the differential isotope method. Hydrogen had a larger partial molar volume than deuterium in niobium, but the reverse was true in vanadium. The isotope effect measured in niobium can be represented as being due to the larger amplitude of vibration of the hydrogen atom than the deuterium atom in the metal lattice. Since hydrogen has a larger mean displacement from the equilibrium position than does deuterium, the average force hydrogen exerts on the metal atoms is greater than the force deuterium exerts. The isotope effect in vanadium is likely a result of anharmonic effects in the lattice and local vibrational modes

  17. The unfolding effects on the protein hydration shell and partial molar volume: a computational study.

    Science.gov (United States)

    Del Galdo, Sara; Amadei, Andrea

    2016-10-12

    In this paper we apply the computational analysis recently proposed by our group to characterize the solvation properties of a native protein in aqueous solution, and to four model aqueous solutions of globular proteins in their unfolded states thus characterizing the protein unfolded state hydration shell and quantitatively evaluating the protein unfolded state partial molar volumes. Moreover, by using both the native and unfolded protein partial molar volumes, we obtain the corresponding variations (unfolding partial molar volumes) to be compared with the available experimental estimates. We also reconstruct the temperature and pressure dependence of the unfolding partial molar volume of Myoglobin dissecting the structural and hydration effects involved in the process.

  18. Partial molar volumes of hydrogen and deuterium in niobium, vanadium, and tantalum

    International Nuclear Information System (INIS)

    Peterson, D.T.; Herro, H.M.

    1983-01-01

    The partial molar volumes of hydrogen and deuterium were measured in vanadium, niobium, and tantalum by a differential pressure technique. One-half of an electrolytically charged sample plat was compressed between hardened steel blocks in a hydraulic press. The activity of hydrogen in the hig pressure region was raised and caused hydrogen to diffuse into the low pressure region. The partia molar volume was calculated from the ratio of the hydrogen concentrations in the high and low pressure regions of the sample. Small isotope effects were found in the partial molar volume. Hydrogen had the larger volume in niobium and tantalum, but the reverse was true in vanadium

  19. Determination of partial molar volumes from free energy perturbation theory†

    Science.gov (United States)

    Vilseck, Jonah Z.; Tirado-Rives, Julian

    2016-01-01

    Partial molar volume is an important thermodynamic property that gives insights into molecular size and intermolecular interactions in solution. Theoretical frameworks for determining the partial molar volume (V°) of a solvated molecule generally apply Scaled Particle Theory or Kirkwood–Buff theory. With the current abilities to perform long molecular dynamics and Monte Carlo simulations, more direct methods are gaining popularity, such as computing V° directly as the difference in computed volume from two simulations, one with a solute present and another without. Thermodynamically, V° can also be determined as the pressure derivative of the free energy of solvation in the limit of infinite dilution. Both approaches are considered herein with the use of free energy perturbation (FEP) calculations to compute the necessary free energies of solvation at elevated pressures. Absolute and relative partial molar volumes are computed for benzene and benzene derivatives using the OPLS-AA force field. The mean unsigned error for all molecules is 2.8 cm3 mol−1. The present methodology should find use in many contexts such as the development and testing of force fields for use in computer simulations of organic and biomolecular systems, as a complement to related experimental studies, and to develop a deeper understanding of solute–solvent interactions. PMID:25589343

  20. Determination of partial molar volumes from free energy perturbation theory.

    Science.gov (United States)

    Vilseck, Jonah Z; Tirado-Rives, Julian; Jorgensen, William L

    2015-04-07

    Partial molar volume is an important thermodynamic property that gives insights into molecular size and intermolecular interactions in solution. Theoretical frameworks for determining the partial molar volume (V°) of a solvated molecule generally apply Scaled Particle Theory or Kirkwood-Buff theory. With the current abilities to perform long molecular dynamics and Monte Carlo simulations, more direct methods are gaining popularity, such as computing V° directly as the difference in computed volume from two simulations, one with a solute present and another without. Thermodynamically, V° can also be determined as the pressure derivative of the free energy of solvation in the limit of infinite dilution. Both approaches are considered herein with the use of free energy perturbation (FEP) calculations to compute the necessary free energies of solvation at elevated pressures. Absolute and relative partial molar volumes are computed for benzene and benzene derivatives using the OPLS-AA force field. The mean unsigned error for all molecules is 2.8 cm(3) mol(-1). The present methodology should find use in many contexts such as the development and testing of force fields for use in computer simulations of organic and biomolecular systems, as a complement to related experimental studies, and to develop a deeper understanding of solute-solvent interactions.

  1. Apparent molar volumes and apparent molar heat capacities of aqueous D-lactose · H2O at temperatures from (278.15 to 393.15) K and at the pressure 0.35 MPa

    International Nuclear Information System (INIS)

    Sargent, J.D.; Niederhauser, T.L.; Woolley, E.M.

    2004-01-01

    Apparent molar volumes V phi and apparent molar heat capacities C p,phi were determined for aqueous solutions of D-lactose · H 2 O at molalities (0.01 to 0.34) mol · kg -1 at temperatures (278.15 to 393.15) K, and at the pressure 0.35 MPa. Our V phi values were calculated from densities obtained using a vibrating tube densimeter, and our C p,phi values were obtained using a twin fixed-cell, power-compensation, differential-output, temperature-scanning calorimeter. Our results for D-lactose(aq) and for D-lactcose · H 2 O were fitted to functions of m and T and compared with the literature results for aqueous D-glucose and D-galactose solutions. Infinite dilution partial molar volumes V 2 compfn and heat capacities C p,2 compfn are given over the range of temperatures

  2. Apparent molar volumes and apparent molar heat capacities of aqueous magnesium nitrate, strontium nitrate, and manganese nitrate at temperatures from 278.15 K to 393.15 K and at the pressure 0.35 MPa

    International Nuclear Information System (INIS)

    Jones, J.S.; Ziemer, S.P.; Brown, B.R.; Woolley, E.M.

    2007-01-01

    Apparent molar volumes V φ and apparent molar heat capacities C p,φ were determined at the pressure 0.35 MPa for aqueous solutions of magnesium nitrate Mg(NO 3 ) 2 at molalities m = (0.02 to 1.0) mol . kg -1 , strontium nitrate Sr(NO 3 ) 2 at m = (0.05 to 3.0) mol . kg -1 , and manganese nitrate Mn(NO 3 ) 2 at m = (0.01 to 0.5) mol . kg -1 . Our V φ values were calculated from solution densities obtained at T = (278.15 to 368.15) K using a vibrating-tube densimeter, and our C p,φ values were calculated from solution heat capacities obtained at T = (278.15 to 393.15) K using a twin fixed-cell, differential, temperature-scanning calorimeter. Empirical functions of m and T were fitted to our results, and standard state partial molar volumes and heat capacities were obtained over the ranges of T investigated

  3. Partial molar volume of n-alcohols at infinite dilution in water calculated by means of scaled particle theory.

    Science.gov (United States)

    Graziano, Giuseppe

    2006-04-07

    The partial molar volume of n-alcohols at infinite dilution in water is smaller than the molar volume in the neat liquid phase. It is shown that the formula for the partial molar volume at infinite dilution obtained from the scaled particle theory equation of state for binary hard sphere mixtures is able to reproduce in a satisfactory manner the experimental data over a large temperature range. This finding implies that the packing effects play the fundamental role in determining the partial molar volume at infinite dilution in water also for solutes, such as n-alcohols, forming H bonds with water molecules. Since the packing effects in water are largely related to the small size of its molecules, the latter feature is the ultimate cause of the decrease in partial molar volume associated with the hydrophobic effect.

  4. Partial and apparent molar volumes of aqueous solutions of the 1:1 type electrolytes

    International Nuclear Information System (INIS)

    Klugman, I.Yu.

    2002-01-01

    Formulas for calculating partial and apparent molar volumes of MX (M=Li-Cs; X = Cl-I) electrolyte aqueous solutions in a wide range of concentrations from 0 to 4 mol/kg with error not in excess of 0.05% are suggested. It is shown that the previously employed formulas for calculating partial molar volumes of electrolytes give false indications of mutual effect of ions and actually they are fit solely for very small concentrations [ru

  5. Thermodynamics of aqueous methyldiethanolamine (MDEA) and methyldiethanolammonium chloride (MDEAH+Cl-) over a wide range of temperature and pressure: Apparent molar volumes, heat capacities, and isothermal compressibilities

    International Nuclear Information System (INIS)

    Hawrylak, B.; Palepu, R.; Tremaine, Peter R.

    2006-01-01

    Apparent molar volumes of aqueous methyldiethanolamine and its salt were determined with platinum vibrating tube densitometers over a range of temperatures from 283K= o , heat capacities C p o , and isothermal compressibilities κ T o . The standard partial molar volumes V o for the neutral amine and its salt show increasingly positive and negative values, respectively, at high temperatures and pressures, as predicted by corresponding states and group additivity arguments. The density model and the revised Helgeson-Kirkham-Flowers (HKF) model have been used to represent the temperature and pressure dependence of the standard partial molar properties to yield a full thermodynamic description of the system

  6. Apparent molar volumes and apparent molar heat capacities of dilute aqueous solutions of ethanol, 1-propanol, and 2-propanol at temperatures from 278.15 K to 393.15 K and at the pressure 0.35 MPa

    International Nuclear Information System (INIS)

    Origlia-Luster, M.L.; Woolley, E.M.

    2003-01-01

    Apparent molar volumes V phi and apparent molar heat capacities C p,phi have been determined for dilute aqueous solutions of ethanol, 1-propanol, and 2-propanol at temperatures from 278.15 K to 393.15 K and at the pressure 0.35 MPa. The molalities investigated ranged from 0.05 mol·kg -1 to 1.0 mol·kg -1 . We used a vibrating tube densimeter (DMA 512P, Anton PAAR, Austria) to determine the densities and volumetric properties. Heat capacities were obtained using a twin fixed-cell, power-compensation, differential-output, temperature-scanning calorimeter (NanoDSC 6100, Calorimetry Sciences Corporation, American Fork, UT, USA). The results were fit by regression to equations that describe the surfaces (V phi ,T,m) and (C p,phi ,T,m). Infinite dilution partial molar volumes V 2 0 and heat capacities C 0 p,2 were obtained over the range of temperatures by extrapolation of these surfaces to m=0 mol·kg -1

  7. Standard partial molar volumes of some electrolytes in ethylene carbonate based mixtures

    International Nuclear Information System (INIS)

    Zhao, Yang; Wang, Jianji.; Lu, Hui; Lin, Ruisen

    2004-01-01

    Apparent molar volumes V 2,phi and standard partial molar volumes V 2,phi 0 of LiClO 4 , LiBr and three symmetrical tetraalkylammonium bromides R 4 NBr (R=ethyl, propyl, butyl) have been determined at 298.15 K from precise density measurements in solvent mixtures of ethylene carbonate with tetrahydrofuran (THF), acetonitrile (AN), ethyl acetate (EA) and dimethoxyethane (DME). It is shown that the V 2,phi 0 values of LiClO 4 and LiBr are dependent strongly on the nature of the solvents, whereas the contribution of CH 2 group to the partial molar volume of the tetraalkylammonium salts has nothing to do with the nature of the solvents and the composition of the solvent mixtures. This provided a helpful evidence for the unsolvation of large tetraalkylammonium cations in organic solvents. The results have been discussed from ion-solvent interactions and the dielectric effect of the solvents

  8. Partial Molar Volume of Methanol in Water: Effect of Polarizability

    Czech Academy of Sciences Publication Activity Database

    Moučka, F.; Nezbeda, Ivo

    2009-01-01

    Roč. 74, č. 4 (2009), s. 559-563 ISSN 0010-0765 R&D Projects: GA AV ČR IAA400720802 Institutional research plan: CEZ:AV0Z40720504 Keywords : water–methanol mixtures * partial molar volume * polarizability Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 0.856, year: 2009

  9. Effect of Molecular Size of Solutes on Their Partial Molar Volumes in Supercritical n-Pentane

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The densities of n-pentane, methane-n-pentane, propane-n-pentane, n-heptane-n-pentane, and n-decane-n-pentane binary mixtures were determined at 476.5K in the pressure range from 2 to 5 MPa. The partial molar volumes of the solutes in n-pentane were calculated using the density data. It was found that the partial molar volumes of methane and propane are positive , while those of n-heptane and n-decane are negative.

  10. Infinitely dilute partial molar properties of proteins from computer simulation.

    Science.gov (United States)

    Ploetz, Elizabeth A; Smith, Paul E

    2014-11-13

    A detailed understanding of temperature and pressure effects on an infinitely dilute protein's conformational equilibrium requires knowledge of the corresponding infinitely dilute partial molar properties. Established molecular dynamics methodologies generally have not provided a way to calculate these properties without either a loss of thermodynamic rigor, the introduction of nonunique parameters, or a loss of information about which solute conformations specifically contributed to the output values. Here we implement a simple method that is thermodynamically rigorous and possesses none of the above disadvantages, and we report on the method's feasibility and computational demands. We calculate infinitely dilute partial molar properties for two proteins and attempt to distinguish the thermodynamic differences between a native and a denatured conformation of a designed miniprotein. We conclude that simple ensemble average properties can be calculated with very reasonable amounts of computational power. In contrast, properties corresponding to fluctuating quantities are computationally demanding to calculate precisely, although they can be obtained more easily by following the temperature and/or pressure dependence of the corresponding ensemble averages.

  11. Partial molar volume of anionic polyelectrolytes in aqueous solution.

    Science.gov (United States)

    Salamanca, Constain; Contreras, Martín; Gamboa, Consuelo

    2007-05-15

    In this work the partial molar volumes (V) of different anionic polyelectrolytes and hydrophobically modified polyelectrolytes (PHM) were measured. Polymers like polymaleic acid-co-styrene, polymaleic acid-co-1-olefin, polymaleic acid-co-vinyl-2-pyrrolidone, and polyacrylic acid (abbreviated as MAS-n, PA-n-K2, AMVP, and PAA, respectively) were employed. These materials were investigated by density measurements in highly dilute aqueous solutions. The molar volume results allow us to discuss the effect of the carboxylic groups and the contributions from the comonomeric principal chain. The PAA presents the smaller V, while the largest V value was for AMVP. The V of PHM shows a linear relationship with the number of methylene groups in the lateral chain. It is found that the magnitude of the contribution per methylene group decreases as the hydrophobic character of the environment increases.

  12. Determination of Partial Molar Volumes of EPA and DHA Ethyl Esters in Supercritical Carbon Dioxide

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The use of supercritical-fluid chromatography for determining partial molar volumes of ethyl esters of cis-5,8,11,14,17-eicosapentaenoic acid (EPA) and cis -4,7,10,13,16,19- docosa-hexaenoic acid (DHA) in supercritical carbon dioxide is presented and discussed. Partial molar volumes of EPA and DHA esters are obtained from the variation of the retention properties with the density of mobile phase at 313.15 K, 323.15 K, 333.15 K and in the pressure range from 9 MPa to 21 MPa.

  13. Deptermination of Partial Molar Volumes of EPA and DHA Ethyl Esters in Supercritical Carbon Dioxide

    Institute of Scientific and Technical Information of China (English)

    MeiHUANG; XianDaWANG; 等

    2002-01-01

    The use of supercritical-fluid shromatogrphy for determining partial molar volumes of ethyl esters of cis-5,8,11,14,17-eicosapentaenoic acid (EPA) and cis-4,7,10,13,16,19-docosa-hexaenoic acid(DHA) in supercritical carbon dioxide is presented and discussed. Partial molar volumes of EPA and DHA esters are obtained from the variation of the retention properties with the density of mobile phase at 313.15K,323.15K,333.15K and in the pressure range from 9 MPa to 21 MPa.

  14. Partial molar volumes of (acetonitrile + water) mixtures over the temperature range (273.15 to 318.15) K

    International Nuclear Information System (INIS)

    Yeow, Y. Leong; Leong, Yee-Kwong

    2007-01-01

    Isothermal molar volume data of (acetonitrile + water) mixtures, between T = 273.15 K and T = 318.15 K, extracted from different sources are combined and treated as a single set to even out minor differences between sources and to increase the number of data points for each temperature. Tikhonov regularization is applied to compute the isothermal first and second derivatives of these data with respect to molar composition. For the reference temperature of 298.15 K, this computation is extended to the third derivative. Generalized Cross Validation is used to guide the selection of the regularization parameter that keeps noise amplification under control. The resulting first derivatives are used to construct the partial molar volume curves which are then checked against published results. Properties of the partial molar volumes are analysed by examining their derivatives. Finally the general shape of the second derivative curve of molar volume is explained qualitatively in terms of tripartite segmentation of the molar composition interval but quantitative comparisons are required to confirm this explanation

  15. Partial molar volumes of some drug and pro-drug substances in 1-octanol at T = 298.15 K

    International Nuclear Information System (INIS)

    Manin, Alex N.; Shmukler, Liudmila E.; Safonova, Liubov P.; Perlovich, German L.

    2010-01-01

    The article deals with measuring the densities of phenol, acetanilide, benzamide, benzoic acid, phenacetin, i-(acetylamino)-benzoic acid, i-hydroxy-benzamide, and i-acetaminophen (where i = 1, 2, 3) in 1-octanol in the wide concentration interval at T = 298.15 K. It also concerns the evaluation of apparent molar volumes and partial molar volumes at infinite dilution, V 2 0 -bar as well as comparative analysis of the free volumes per molecule in the octanolic solutions, V 2 free , and in the crystal lattices, V 2 free (cr), from the nature and position of the substitutes. Also described is the evaluation of the increments of V 2 0 -bar andV 2 free for the unsubstituted molecules and isomers and the methods to obtain partial molar volumes for various functional groups at infinite dilution in 1-octanol at T = 298.15 K. Also considered is the limiting partial molar volume of the solutes in terms of the scaled particle theory.

  16. Partial molar volume of mefenamic acid in alcohol at temperatures between T=293.15 and T=313.15 K

    OpenAIRE

    Iqbal, Muhammad J.; Siddiquah, Mahrukh

    2006-01-01

    Apparent molar volume (Vphi), partial molar volume (V), solute-solute interaction parameter (Sv), partial molar expansivity (E(0)2) and isobaric thermal expansion coefficient (alpha2) of mefenamic acid in six different organic solvents namely, methanol, ethanol, 1-propanol, 2-propanol, 1-butanol, and 2-butanol, have been calculated from the measured solution densities over a temperature range of T=293.15 and T=313.15±0.1K. The solution densities were measured by an automated vibrating tube de...

  17. Ab initio calculations of partial molar properties in the single-site approximation

    DEFF Research Database (Denmark)

    Ruban, Andrei; Skriver, Hans Lomholt

    1997-01-01

    We discuss the application of the single-site approximation in calculations of partial molar quantities, e.g., impurity solution energy, segregation energy, and effective chemical potential, which are related to a variation of the composition of an alloy or its nonequivalent parts. We demonstrate...

  18. Thermodynamic study of (heptane + amine) mixtures. II. Excess and partial molar volumes at 298.15 K

    International Nuclear Information System (INIS)

    Lepori, Luciano; Gianni, Paolo; Spanedda, Andrea; Matteoli, Enrico

    2011-01-01

    Research highlights: → Excess and partial molar volumes of primary (amines + heptane) mixtures. → Excess volumes are positive for small size amines and decrease as the size increases. → Group contributions to predict the partial molar volumes of amines in heptane. → The void volume is larger for branched than for linear amines in heptane. - Abstract: Excess molar volumes V E at 298.15 K were determined by means of a vibrating tube densimeter for binary mixtures of heptane + primary n-alkyl (C 3 to C 10 ) and branched amines (iso-propyl-, iso-, sec-, and tert-butyl-, iso-, tert-pentyl-, and pentan-3-amine) in the whole composition range. The apparent molar volumes of solid dodecyl- and tetradecylamine in heptane dilute solution were also determined. The V E values were found positive for mixtures involving C 3 to C 8 linear amines, with V E decreasing with chain lengthening. Heptane + nonyl and decylamine showed s-shaped, markedly asymmetric, curves. Mixtures with branched C 3 to C 5 amines displayed positive V E 's larger than those observed in the mixtures of the corresponding linear isomers. Partial molar volumes V o at infinite dilution in heptane were evaluated for the examined amines and compared with those of alkanes and alkanols taken from the literature. An additivity scheme, based on the intrinsic volume approach, was applied to estimate group (CH 3 , CH 2 , CH, C, NH 2 , and OH) contributions to V o . The effect of branching on V o and the limiting slope of the apparent excess molar volumes were evaluated and discussed in terms of solute-solvent and solute-solute interactions.

  19. On a relationship between molecular polarizability and partial molar volume in water.

    Science.gov (United States)

    Ratkova, Ekaterina L; Fedorov, Maxim V

    2011-12-28

    We reveal a universal relationship between molecular polarizability (a single-molecule property) and partial molar volume in water that is an ensemble property characterizing solute-solvent systems. Since both of these quantities are of the key importance to describe solvation behavior of dissolved molecular species in aqueous solutions, the obtained relationship should have a high impact in chemistry, pharmaceutical, and life sciences as well as in environments. We demonstrated that the obtained relationship between the partial molar volume in water and the molecular polarizability has in general a non-homogeneous character. We performed a detailed analysis of this relationship on a set of ~200 organic molecules from various chemical classes and revealed its fine well-organized structure. We found that this structure strongly depends on the chemical nature of the solutes and can be rationalized in terms of specific solute-solvent interactions. Efficiency and universality of the proposed approach was demonstrated on an external test set containing several dozens of polyfunctional and druglike molecules.

  20. Molar Pregnancy

    Science.gov (United States)

    ... weeks of pregnancy Ovarian cysts Anemia Overactive thyroid (hyperthyroidism) Causes A molar pregnancy is caused by an ... have this complication than a partial molar pregnancy. Prevention If you've had a molar pregnancy, talk ...

  1. Standard molar volumes and heat capacities of aqueous solutions of sodium trifluoromethanesulfonate at temperatures up to 573 K and pressures to 28 MPa

    International Nuclear Information System (INIS)

    Pourtier, Emilie; Ballerat-Busserolles, Karine; Majer, Vladimir; Šedlbauer, Josef

    2013-01-01

    Highlights: ► Original HT/HP data for NaTr(aq) obtained using non-commercial instruments. ► First heat capacity data for NaTr(aq) at conditions remote from ambient. ► Correction for association when calculating stand. therm. properties of Tr(aq) anion. - Abstract: Densities and heat capacities of aqueous solutions of sodium trifluoromethanesulfonate (sodium triflate) of concentrations from 0.025 to 0.3 mol · kg −1 were measured with high temperature, high pressure custom-made instruments at temperatures up to 573 K and at pressures up to 28 MPa. Standard molar volumes and standard molar heat capacities were obtained via extrapolation of the apparent molar properties to infinite dilution. The results for volumetric properties are consistent with earlier literature data, but no previous measurements exist for heat capacities of sodium triflate at superambient conditions. The new data were used for calculating the standard molar volumes and heat capacities for the triflate anion and compared with the results for triflic acid that should be essentially identical within the expected error margins. At temperatures above 473 K an effort was made to refine the processing of literature data for HCl(aq), taking into account its partial association, and subsequently to modify the value for Na + ion calculated from the standard thermodynamic values of NaCl(aq) where its ion pairing was already considered. This approach yields reasonable agreement at high temperatures between the values for triflate ion calculated from its salt and those for triflic acid.

  2. Infinite dilution partial molar volumes of platinum(II) 2,4-pentanedionate in supercritical carbon dioxide.

    Science.gov (United States)

    Kong, Chang Yi; Siratori, Tomoya; Funazukuri, Toshitaka; Wang, Guosheng

    2014-10-03

    The effects of temperature and density on retention of platinum(II) 2,4-pentanedionate in supercritical fluid chromatography were investigated at temperatures of 308.15-343.15K and pressure range from 8 to 40MPa by the chromatographic impulse response method with curve fitting. The retention factors were utilized to derive the infinite dilution partial molar volumes of platinum(II) 2,4-pentanedionate in supercritical carbon dioxide. The determined partial molar volumes were small and positive at high pressures but exhibited very large and negative values in the highly compressible near critical region of carbon dioxide. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Partial molar volumes of some drug and pro-drug substances in 1-octanol at T = 298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Manin, Alex N.; Shmukler, Liudmila E.; Safonova, Liubov P. [Institute of Solution Chemistry, Russian Academy of Sciences, 153045 Ivanovo (Russian Federation); Perlovich, German L., E-mail: glp@isc-ras.r [Institute of Solution Chemistry, Russian Academy of Sciences, 153045 Ivanovo (Russian Federation)

    2010-03-15

    The article deals with measuring the densities of phenol, acetanilide, benzamide, benzoic acid, phenacetin, i-(acetylamino)-benzoic acid, i-hydroxy-benzamide, and i-acetaminophen (where i = 1, 2, 3) in 1-octanol in the wide concentration interval at T = 298.15 K. It also concerns the evaluation of apparent molar volumes and partial molar volumes at infinite dilution, V{sub 2}{sup 0}-bar as well as comparative analysis of the free volumes per molecule in the octanolic solutions, V{sub 2}{sup free}, and in the crystal lattices, V{sub 2}{sup free} (cr), from the nature and position of the substitutes. Also described is the evaluation of the increments of V{sub 2}{sup 0}-bar andV{sub 2}{sup free} for the unsubstituted molecules and isomers and the methods to obtain partial molar volumes for various functional groups at infinite dilution in 1-octanol at T = 298.15 K. Also considered is the limiting partial molar volume of the solutes in terms of the scaled particle theory.

  4. Relationship between the partial molar and molar quantity of a thermodynamic state function in a multicomponent mixture – revisited

    International Nuclear Information System (INIS)

    Näfe, H.

    2013-01-01

    As far as a multicomponent mixture is concerned, different versions exist in the literature for the relationship between the partial molar and molar quantity of a thermodynamic state function with the most prominent example of the two quantities being the activity coefficient of an arbitrary component and the excess Gibbs free energy of a mixture comprising this component. Since the relationships published so far have to a large degree been derived independently of each other and result from apparently conflicting approaches, they are still considered as separate subjects in the literature. It is demonstrated that despite this curious situation all relationships are equivalent to each other from a mathematical point of view

  5. Electrolytic conductivity and molar heat capacity of two aqueous solutions of ionic liquids at room-temperature: Measurements and correlations

    International Nuclear Information System (INIS)

    Lin Peiyin; Soriano, Allan N.; Leron, Rhoda B.; Li Menghui

    2010-01-01

    As part of our systematic study on physicochemical characterization of ionic liquids, in this work, we report new measurements of electrolytic conductivity and molar heat capacity for aqueous solutions of two 1-ethyl-3-methylimidazolium-based ionic liquids, namely: 1-ethyl-3-methylimidazolium dicyanamide and 1-ethyl-3-methylimidazolium 2-(2-methoxyethoxy) ethylsulfate, at normal atmospheric condition and for temperatures up to 353.2 K. The electrolytic conductivity and molar heat capacity were measured by a commercial conductivity meter and a differential scanning calorimeter (DSC), respectively. The estimated experimental uncertainties for the electrolytic conductivity and molar heat capacity measurements were ±1% and ±2%, respectively. The property data are reported as functions of temperature and composition. A modified empirical equation from another researcher was used to correlate the temperature and composition dependence of the our electrolytic conductivity results. An excess molar heat capacity expression derived using a Redlich-Kister type equation was used to represent the temperature and composition dependence of the measured molar heat capacity and calculated excess molar heat capacity of the solvent systems considered. The correlations applied represent the our measurements satisfactorily as shown by an acceptable overall average deviation of 6.4% and 0.1%, respectively, for electrolytic conductivity and molar heat capacity.

  6. A study of partial molar volumes of citric acid and tartaric acid

    Indian Academy of Sciences (India)

    Partial molar volumes of citric acid and tartaric acid have been determined in water and binary aqueous mixtures of ethanol (5, 10, 15, 20 and 25% by weight of ethanol) at different temperatures and acid concentrations from the solution density measurements. The data have been evaluated by using Masson equation and ...

  7. Calculation of partial molar volume of components in supercritical ammonia synthesis system

    Institute of Scientific and Technical Information of China (English)

    Cunwen WANG; Chuanbo YU; Wen CHEN; Weiguo WANG; Yuanxin WU; Junfeng ZHANG

    2008-01-01

    The partial molar volumes of components in supercritical ammonia synthesis system are calculated in detail by the calculation formula of partial molar volume derived from the R-K equation of state under different conditions. The objectives are to comprehend phase beha-vior of components and to provide the theoretic explana-tion and guidance for probing novel processes of ammonia synthesis under supercritical conditions. The conditions of calculation are H2/N2= 3, at a concentra-tion of NH3 in synthesis gas ranging from 2% to 15%, Concentration of medium in supercritical ammonia syn-thesis system ranging from 20% to 50%, temperature ran-ging from 243 K to 699 K and pressure ranging from 0.1 MPa to 187 MPa. The results show that the ammonia synthesis system can reach supercritical state by adding a suitable supercritical medium and then controlling the reaction conditions. It is helpful for the supercritical ammonia synthesis that medium reaches supercritical state under the conditions of the corresponding total pres-sure and components near the normal temperature or near the critical temperature of medium or in the range of tem-perature of industrialized ammonia synthesis.

  8. Partial Molar Volumes of 15-Crown-5 Ether in Mixtures of N,N-Dimethylformamide with Water.

    Science.gov (United States)

    Tyczyńska, Magdalena; Jóźwiak, Małgorzata

    2014-01-01

    The density of 15-crown-5 ether (15C5) solutions in the mixtures of N,N -dimethylformamide (DMF) and water (H 2 O) was measured within the temperature range 293.15-308.15 K using an Anton Paar oscillatory U-tube densimeter. The results were used to calculate the apparent molar volumes ( V Φ ) of 15C5 in the mixtures of DMF + H 2 O over the whole concentration range. Using the apparent molar volumes and Redlich and Mayer equation, the standard partial molar volumes of 15-crown-5 were calculated at infinite dilution ([Formula: see text]). The limiting apparent molar expansibilities ( α ) were also calculated. The data are discussed from the point of view of the effect of concentration changes on interactions in solution.

  9. Measurement of the molar heat capacities of MoO2 and MoO3 from 350 to 950 K

    International Nuclear Information System (INIS)

    Inaba, H.; Miyahara, K.; Naito, K.

    1984-01-01

    Molar heat capacities of MoO 2 and MoO 3 were measured in the range between 350 and 950 K by means of adiabatic scanning calorimetry. For MoO 2 , a sharp heat-capacity anomaly with a molar enthalpy change of (178 +- 24) J.mol -1 and a molar entropy change of (0.207 +- 0.028) J.K -1 .mol -1 was observed at 865 K, which had not been detected by drop calorimetry. For MoO 3 , two heat-capacity anomalies with molar enthalpy changes of (88 +- 21) and (60 +- 36) J.mol -1 were found at 808 K and 857 K, respectively; neither anomaly had been detected by the drop method. The lattice molar heat capacities of MoO 2 and MoO 3 are estimated as Csub(l,m)(MoO 2 ) = D(469 K/T) + E(578 K/T) + E(876 K/T) and Csub(l,m)(MoO 3 ) = D(208 K/T) + 2E(488 K/T) + E(1170 K/T), where D(x) and E(x) are the Debye and Einstein functions, respectively. The temperature coefficient of the electronic molar heat capacity of MoO 2 is estimated as (6.0 +- 0.5) mJ.K -2 .mol -1 . The excess heat capacity in MoO 3 found at higher temperatures is interpreted as being due to vacancy formation with a molar activation energy of (98 +-5) kJ.mol -1 . The origin of the heat-capacity anomalies is inferred as arising from the slight movement of distorted MoO 6 octahedra in the MoO 2 and MoO 3 structures. (author)

  10. A principle to correlate extreme values of excess thermodynamic functions with partial molar quantities

    Institute of Scientific and Technical Information of China (English)

    尉志武; 刘芸; 周蕊; 薛芳渝

    2001-01-01

    Excess thermodynamic properties are widely used quantitatively for fluids. It was found that at constant temperature and pressure a molar excess quantity of a mutually miscible binary mixture at the extreme points equals the excess partial molar quantities of the two components, i.e.F1E = F2E = FmE , forming a triple cross point. The relationship is hold for properties such as en-thalpy, entropy, Gibbs free energy, and volume, and is applicable for excess functions with multi extreme points. Solutions at extreme points can be referred to as special mixtures. Particularly fora special mixture of Gibbs free energy, activity coefficients of the two components are identical.

  11. Hydrophobic hydration and the anomalous partial molar volumes in ethanol-water mixtures

    International Nuclear Information System (INIS)

    Tan, Ming-Liang; Te, Jerez; Cendagorta, Joseph R.; Miller, Benjamin T.; Brooks, Bernard R.; Ichiye, Toshiko

    2015-01-01

    The anomalous behavior in the partial molar volumes of ethanol-water mixtures at low concentrations of ethanol is studied using molecular dynamics simulations. Previous work indicates that the striking minimum in the partial molar volume of ethanol V E as a function of ethanol mole fraction X E is determined mainly by water-water interactions. These results were based on simulations that used one water model for the solute-water interactions but two different water models for the water-water interactions. This is confirmed here by using two more water models for the water-water interactions. Furthermore, the previous work indicates that the initial decrease is caused by association of the hydration shells of the hydrocarbon tails, and the minimum occurs at the concentration where all of the hydration shells are touching each other. Thus, the characteristics of the hydration of the tail that cause the decrease and the features of the water models that reproduce this type of hydration are also examined here. The results show that a single-site multipole water model with a charge distribution that mimics the large quadrupole and the p-orbital type electron density out of the molecular plane has “brittle” hydration with hydrogen bonds that break as the tails touch, which reproduces the deep minimum. However, water models with more typical site representations with partial charges lead to flexible hydration that tends to stay intact, which produces a shallow minimum. Thus, brittle hydration may play an essential role in hydrophobic association in water

  12. Low-tmperature Heat Capacities and Standard Molar Enthalpy of Formation of 4-Nitrobenzyl Alcohol

    Institute of Scientific and Technical Information of China (English)

    MENG, Qingfen; TAN, Zhicheng; WANG, Xiaohuan; DONG, Yaping; LI, Wu; SHI, Quan

    2009-01-01

    Low-temperature heat capacities of 4-nitrobenzyl alcohol (4-NBA) have been measured by a high precision automated adiabatic calorimeter over the temperature range from 78 to 396 K. The melting temperature, the molar calculated in the range from 80 to 400 K at the interval of 5 K. The constant-volume energy and standard molar en- at T=298.15 K. The standard molar enthalpy of formation has been derived, ΔfHom(C7H7NO3, s)=-(206.49± namic quantities through a Hess thermochemical cycle.

  13. A principle to correlate extreme values of excess thermody-namic functions with partial molar quantities

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Excess thermodynamic properties are widely used quantitatively for fluids. It was found that at constant temperature and pressure a molar excess quantity of a mutually miscible binary mixture at the extreme points equals the excess partial molar quantities of the two components, i.e. , forming a triple cross point. The relationship is hold for properties such as enthalpy, entropy, Gibbs free energy, and volume, and is applicable for excess functions with multi extreme points. Solutions at extreme points can be referred to as special mixtures. Particularly for a special mixture of Gibbs free energy, activity coefficients of the two components are identical.

  14. The (water + acetonitrile) mixture revisited: A new approach for calculating partial molar volumes

    International Nuclear Information System (INIS)

    Carmen Grande, Maria del; Julia, Jorge Alvarez; Barrero, Carmen R.; Marschoff, Carlos M.; Bianchi, Hugo L.

    2006-01-01

    Density and viscosity of (water + acetonitrile) mixtures were measured over the whole composition range at the temperatures: (298.15, 303.15, 308.15, 313.15, and 318.15) K. A new mathematical approach was developed which allows the calculation of the derivatives of density with respect to composition avoiding the appearance of local discontinuities. Thus, reliable partial molar volumes and thermal expansion coefficients were obtained

  15. Quadrupole terms in the Maxwell equations: Born energy, partial molar volume, and entropy of ions.

    Science.gov (United States)

    Slavchov, Radomir I; Ivanov, Tzanko I

    2014-02-21

    A new equation of state relating the macroscopic quadrupole moment density Q to the gradient of the field ∇E in an isotropic fluid is derived: Q = αQ(∇E - U∇·E/3), where the quadrupolarizability αQ is proportional to the squared molecular quadrupole moment. Using this equation of state, a generalized expression for the Born energy of an ion dissolved in quadrupolar solvent is obtained. It turns out that the potential and the energy of a point charge in a quadrupolar medium are finite. From the obtained Born energy, the partial molar volume and the partial molar entropy of a dissolved ion follow. Both are compared to experimental data for a large number of simple ions in aqueous solutions. From the comparison the value of the quadrupolar length LQ is determined, LQ = (αQ/3ɛ)(1/2) = 1-4 Å. Data for ion transfer from aqueous to polar oil solution are analyzed, which allowed for the determination of the quadrupolarizability of nitrobenzene.

  16. Partial molar volume of proteins studied by the three-dimensional reference interaction site model theory.

    Science.gov (United States)

    Imai, Takashi; Kovalenko, Andriy; Hirata, Fumio

    2005-04-14

    The three-dimensional reference interaction site model (3D-RISM) theory is applied to the analysis of hydration effects on the partial molar volume of proteins. For the native structure of some proteins, the partial molar volume is decomposed into geometric and hydration contributions using the 3D-RISM theory combined with the geometric volume calculation. The hydration contributions are correlated with the surface properties of the protein. The thermal volume, which is the volume of voids around the protein induced by the thermal fluctuation of water molecules, is directly proportional to the accessible surface area of the protein. The interaction volume, which is the contribution of electrostatic interactions between the protein and water molecules, is apparently governed by the charged atomic groups on the protein surface. The polar atomic groups do not make any contribution to the interaction volume. The volume differences between low- and high-pressure structures of lysozyme are also analyzed by the present method.

  17. Experimental heat capacity of solid hydrogen as a function of molar volume

    International Nuclear Information System (INIS)

    Krause, J.K.

    1978-01-01

    Constant volume heat capacity measurements have been made on six solid hydrogen samples with low orthohydrogen concentrations. The measurements extend from approximately 1.5 K to the melting line, with molar volumes ranging from 22.787 cm 3 /mole to 16.193 cm 3 /mole. Although clustering of the ortho molecules was observed, the low temperature heat capacity anomaly due to the orthohydrogen pairs could be described quite well by the assumption of a fixed distribution. The data were corrected to obtain a lattice heat capacity which on extrapolation to T = 0 yielded Debye temperatures and a volume dependent Grueneisen parameter. A modified Mie-Grueneisen approximation was used to define a volume and temperature dependent Grueneisen parameter which was used to calculate the equation of state, P(V,T), and isothermal bulk modulus, B/sub T/(V,T), for the six isochores. An extrapolation of the equation of state to T = 0 and P = 0 by two different methods yields a molar volume which, when compared with other determinations, gives a recommended value of 23.20 +- 0.05 cm 3 /mole. A rapid increase in the conversion rate of orthohydrogen to parahydrogen was observed at approximately theta/sub o/12. The molar volumes along the melting curve also have been determined directly for the first time in this volume range. These results have been used to show that a low temperature Lindemann melting relation is only approximately valid for solid hydrogen to 50 K

  18. Hydration of alcohol clusters in 1-propanol-water mixture studied by quasielastic neutron scattering and an interpretation of anomalous excess partial molar volume.

    Science.gov (United States)

    Misawa, M; Inamura, Y; Hosaka, D; Yamamuro, O

    2006-08-21

    Quasielastic neutron scattering measurements have been made for 1-propanol-water mixtures in a range of alcohol concentration from 0.0 to 0.167 in mole fraction at 25 degrees C. Fraction alpha of water molecules hydrated to fractal surface of alcohol clusters in 1-propanol-water mixture was obtained as a function of alcohol concentration. Average hydration number N(ws) of 1-propanol molecule is derived from the value of alpha as a function of alcohol concentration. By extrapolating N(ws) to infinite dilution, we obtain values of 12-13 as hydration number of isolated 1-propanol molecule. A simple interpretation of structural origin of anomalous excess partial molar volume of water is proposed and as a result a simple equation for the excess partial molar volume is deduced in terms of alpha. Calculated values of the excess partial molar volumes of water and 1-propanol and the excess molar volume of the mixture are in good agreement with experimental values.

  19. Low-temperature heat capacities and standard molar enthalpy of formation of N-methylnorephedrine C211H17NO(s)

    Institute of Scientific and Technical Information of China (English)

    Di You-Ying; Wang Da-Qi; Shi Quan; Tan Zhi-Cheng

    2008-01-01

    This paper reports that low-temperature heat capacities of N-methylnorephedrine C11H17NO(s) have been mea- sured by a precision automated adiabatic calorimeter over the temperature range from T=78 K to T=400 K. A solid to liquid phase transition of the compound was found in the heat capacity curve in the temperature range of T=342- 364 K. The peak temperature, molar enthalpy and entropy of fusion of the substance were determined. The experimental values of the molar heat capacities in the temperature regions of T=78-342 K and T=364-400 K were fitted to two poly- nomial equations of heat capacities with the reduced temperatures by least squares method. The smoothed molar heat capacities and thermodynamic functions of N-methylnorephedrine C11H17NO(s) relative to the standard refer- ence temperature 298.15 K were calculated based on the fitted polynomials and tabulated with an interval of 5 K. The constant-volume energy of combustion of the compound at T=298.15 K was measured by means of an isoperibol preci- sion oxygen-bomb combustion calorimeter. The standard molar enthalpy of combustion of the sample was calculated. The standard molar enthalpy of formation of the compound was determined from the combustion enthalpy and other auxiliary thermodynamic data through a Hess thermochemical cycle.

  20. Partial molar volumes of L-alanine, DL-serine, DL-threonine, L-histidine, glycine, and glycylglycine in water, NaCl, and DMSO aqueous solutions at T 298.15 K

    International Nuclear Information System (INIS)

    Yuan Quan; Li Zhifen; Wang Baohuai

    2006-01-01

    The apparent molar volumes of L-alanine, DL-serine, DL-threonine, L-histidine, glycine, and glycylglycine in water and in the aqueous solutions of NaCl and DMSO with various concentrations at T = 298.15 K have been measured by the precise vibrating-tube digital densimeter. The calculated partial molar volumes at infinite dilution have been used to obtain corresponding transfer volumes from water to various solutions. The experimental results show that the standard partial molar volumes of the above amino acids and peptide at the dilute DMSO aqueous solutions are very close to those in water. However, the volumes show several types of variations with the increase of the concentrations of DMSO due to different types of side chain of amino acids, which should be discussed specifically. The NaCl changes considerably the infinite dilution standard partial molar volumes of the above amino acids and peptide in the aqueous solutions. The infinite dilution standard partial molar volumes of the each amino acids and peptide increase with the concentrations of NaCl. The experimental results have been rationalized by a cosphere overlap model

  1. Heat deposition on the partial limiter

    International Nuclear Information System (INIS)

    Itoh, Kimitaka; Itoh, Sanae-I; Nagasaki, Kazunobu.

    1990-01-01

    The effect of the partial limiter in the outermost magnetic surface of toroidal plasmas is studied. The power deposition on the partial limiter and its effect on the temperature profile are analysed. Interpretation in terms of the perpendicular heat conductivity is also discussed. (author)

  2. Partial Molar Volumes of Air-Component Gases in Several Liquid n-Alkanes and 1-Alkanols at 313.15 K

    Czech Academy of Sciences Publication Activity Database

    Izák, Pavel; Cibulka, I.; Heintz, A.

    1995-01-01

    Roč. 109, č. 2 (1995), s. 227-234 ISSN 0378-3812 Keywords : data density * partial molar volume * gas -liquid mixture Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.024, year: 1995

  3. Note: Nonpolar solute partial molar volume response to attractive interactions with water

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Steven M.; Ashbaugh, Henry S., E-mail: hanka@tulane.edu [Department of Chemical and Biomolecular Engineering, Tulane University, New Orleans, Louisiana 70118 (United States)

    2014-01-07

    The impact of attractive interactions on the partial molar volumes of methane-like solutes in water is characterized using molecular simulations. Attractions account for a significant 20% volume drop between a repulsive Weeks-Chandler-Andersen and full Lennard-Jones description of methane interactions. The response of the volume to interaction perturbations is characterized by linear fits to our simulations and a rigorous statistical thermodynamic expression for the derivative of the volume to increasing attractions. While a weak non-linear response is observed, an average effective slope accurately captures the volume decrease. This response, however, is anticipated to become more non-linear with increasing solute size.

  4. Note: Nonpolar solute partial molar volume response to attractive interactions with water.

    Science.gov (United States)

    Williams, Steven M; Ashbaugh, Henry S

    2014-01-07

    The impact of attractive interactions on the partial molar volumes of methane-like solutes in water is characterized using molecular simulations. Attractions account for a significant 20% volume drop between a repulsive Weeks-Chandler-Andersen and full Lennard-Jones description of methane interactions. The response of the volume to interaction perturbations is characterized by linear fits to our simulations and a rigorous statistical thermodynamic expression for the derivative of the volume to increasing attractions. While a weak non-linear response is observed, an average effective slope accurately captures the volume decrease. This response, however, is anticipated to become more non-linear with increasing solute size.

  5. Towards a universal method for calculating hydration free energies: a 3D reference interaction site model with partial molar volume correction

    International Nuclear Information System (INIS)

    Palmer, David S; Frolov, Andrey I; Ratkova, Ekaterina L; Fedorov, Maxim V

    2010-01-01

    We report a simple universal method to systematically improve the accuracy of hydration free energies calculated using an integral equation theory of molecular liquids, the 3D reference interaction site model. A strong linear correlation is observed between the difference of the experimental and (uncorrected) calculated hydration free energies and the calculated partial molar volume for a data set of 185 neutral organic molecules from different chemical classes. By using the partial molar volume as a linear empirical correction to the calculated hydration free energy, we obtain predictions of hydration free energies in excellent agreement with experiment (R = 0.94, σ = 0.99 kcal mol -1 for a test set of 120 organic molecules). (fast track communication)

  6. Towards a universal method for calculating hydration free energies: a 3D reference interaction site model with partial molar volume correction.

    Science.gov (United States)

    Palmer, David S; Frolov, Andrey I; Ratkova, Ekaterina L; Fedorov, Maxim V

    2010-12-15

    We report a simple universal method to systematically improve the accuracy of hydration free energies calculated using an integral equation theory of molecular liquids, the 3D reference interaction site model. A strong linear correlation is observed between the difference of the experimental and (uncorrected) calculated hydration free energies and the calculated partial molar volume for a data set of 185 neutral organic molecules from different chemical classes. By using the partial molar volume as a linear empirical correction to the calculated hydration free energy, we obtain predictions of hydration free energies in excellent agreement with experiment (R = 0.94, σ = 0.99 kcal mol (- 1) for a test set of 120 organic molecules).

  7. Partial molar volumes and viscosities of aqueous hippuric acid solutions containing LiCl and MnCl2 · 4H2O at 303.15 K

    Science.gov (United States)

    Deosarkar, S. D.; Tawde, P. D.; Zinjade, A. B.; Shaikh, A. I.

    2015-09-01

    Density (ρ) and viscosity (η) of aqueous hippuric acid (HA) solutions containing LiCl and MnCl2 · 4H2O have been studied at 303.15 K in order to understand volumetric and viscometric behavior of these systems. Apparent molar volume (φv) of salts were calculated from density data and fitted to Massons relation and partial molar volumes (φ{v/0}) at infinite dilution were determined. Relative viscosity data has been used to determine viscosity A and B coefficients using Jones-Dole relation. Partial molar volume and viscosity coefficients have been discussed in terms of ion-solvent interactions and overall structural fittings in solution.

  8. Low-temperature heat capacity and standard molar enthalpy of formation of 9-fluorenemethanol (C14H12O)

    International Nuclear Information System (INIS)

    Di, You-Ying; Tan, Zhi-Cheng.; Sun, Xiao-Hong; Wang, Mei-Han; Xu, Fen; Liu, Yuan-Fa; Sun, Li-Xian; Zhang, Hong-Tao

    2004-01-01

    Low-temperature heat capacities of the 9-fluorenemethanol (C 14 H 12 O) have been precisely measured with a small sample automatic adiabatic calorimeter over the temperature range between T=78 K and T=390 K. The solid-liquid phase transition of the compound has been observed to be T fus =(376.567±0.012) K from the heat-capacity measurements. The molar enthalpy and entropy of the melting of the substance were determined to be Δ fus H m =(26.273±0.013) kJ · mol -1 and Δ fus S m =(69.770±0.035) J · K -1 · mol -1 . The experimental values of molar heat capacities in solid and liquid regions have been fitted to two polynomial equations by the least squares method. The constant-volume energy and standard molar enthalpy of combustion of the compound have been determined, Δ c U(C 14 H 12 O, s)=-(7125.56 ± 4.62) kJ · mol -1 and Δ c H m compfn (C 14 H 12 O, s)=-(7131.76 ± 4.62) kJ · mol -1 , by means of a homemade precision oxygen-bomb combustion calorimeter at T=(298.15±0.001) K. The standard molar enthalpy of formation of the compound has been derived, Δ f H m compfn (C 14 H 12 O,s)=-(92.36 ± 0.97) kJ · mol -1 , from the standard molar enthalpy of combustion of the compound in combination with other auxiliary thermodynamic quantities through a Hess thermochemical cycle

  9. Partial molar volume and isentropic compressibility of symmetrical and asymmetrical quaternary ammonium bromides in aqueous solution

    International Nuclear Information System (INIS)

    Moreno, Nicolás; Buchner, Richard; Vargas, Edgar F.

    2015-01-01

    Highlights: • Structural effects of the cations on surrounding water molecules are discussed. • Alkyl-chain geometry determines the hydration of Bu 4 N + isomers. • The “compactness” in the hydration shells varies significantly among the isomers. - Abstract: Values of apparent molar volume and isentropic compressibility of symmetric and asymmetric isomers of tetrabutylammonium bromide, namely tetra-n-butylammonium bromide, tetra-iso-butylammonium bromide, tetra-sec-butylammonium bromide, di-n-butyl-di-iso-butylammonium bromide and di-n-butyl-di-sec-butylammonium bromide, in aqueous solution were determined from density and speed of sound measurements. These properties were obtained as a function of molal concentration within the range of 0.01 < m/mol · kg −1 < 0.1 covering temperatures from 278.15 ⩽ T/K ⩽ 293.15. The partial molar volumes and the apparent isentropic molar compressibility at infinite dilution were calculated and their dependence on temperature examined. The results show that cations with sec-butyl chains have larger structural volumes compared to those with iso-butyl chains. In addition, cations with sec-butyl chains induce smaller structural changes in their hydration shell than the others

  10. Pressure effects on the structure, kinetic, and thermodynamic properties of heat-induced aggregation of protein studied by FT-IR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Y [Applied Chemistry Department, Ritsumeikan University, Kusatsu, Shiga 525-8577 (Japan); Okuno, A [Research Department 3, Central Research, Bridgestone Co. Kodaira, Tokyo 187-8531 (Japan); Kato, M, E-mail: taniguti@sk.ritsumei.ac.j [Pharmaceutical Sciences Department, Ritsumeikan University, Kusatsu, Shiga 525-8577 (Japan)

    2010-03-01

    Pressure can retrain the heat-induced aggregation and dissociate the heat-induced aggregates. We observed the aggregation-preventing pressure effect and the aggregates-dissociating pressure effect to characterize the heat-induced aggregation of equine serum albumin (ESA) by FT-IR spectroscopy. The results suggest the {alpha}-helical structure collapses at the beginning of heat-induced aggregation through the swollen structure, and then the rearrangement of structure to the intermolecular {beta}-sheet takes place through partially unfolded structure. We determined the activation volume for the heat-induced aggregation ({Delta}V'' = +93 ml/mol) and the partial molar volume difference between native state and heat-induced aggregates ({Delta}V=+32 ml/mol). This positive partial molar volume difference suggests that the heat-induced aggregates have larger internal voids than the native structure. Moreover, the positive volume change implies that the formation of the intermolecular {beta}-sheet is unfavorable under high pressure.

  11. Apparent molar volumes and apparent molar heat capacities of Pr(NO3)3(aq), Gd(NO3)3(aq), Ho(NO3)3(aq), and Y(NO3)3(aq) at T (288.15, 298.15, 313.15, and 328.15) K and p = 0.1 MPa

    International Nuclear Information System (INIS)

    Hakin, Andrew W.; Liu Jinlian; Erickson, Kristy; Munoz, Julie-Vanessa; Rard, Joseph A.

    2005-01-01

    Relative densities and relative massic heat capacities have been measured for acidified solutions of Y(NO 3 ) 3 (aq), Pr(NO 3 ) 3 (aq), and Gd(NO 3 ) 3 (aq) at T = (288.15, 298.15, 313.15, and 328.15) K and p = 0.1 MPa. In addition, relative densities and massic heat capacities have been measured at the same temperatures and pressure for Y(NO 3 ) 3 (aq) and Ho(NO 3 ) 3 (aq) solutions without excess acid (n.b. measurements at T = 328.15 K for Ho(NO 3 ) 3 (aq) were not performed due to the limited volume of solution available). Apparent molar volumes and apparent molar heat capacities for the aqueous salt solutions have been calculated from the experimental apparent molar properties of the acidified solutions using Young's rule, whereas the apparent molar properties of the solutions without excess acid were calculated directly from the measured densities and massic heat capacities. The two sets of data for the Y(NO 3 ) 3 (aq) systems provide a check of the internal consistency of the Young's rule approach we have utilised. The concentration dependences of the apparent molar volumes and heat capacities of the aqueous salt solutions have been modelled at each investigated temperature using the Pitzer ion interaction equations to yield apparent molar properties at infinite dilution. Complex formation within the aqueous rare earth nitrate systems is discussed qualitatively by probing the concentration dependence of apparent molar volumes and heat capacities. In spite of the complex formation in the aqueous rare earth nitrate systems, there is a high degree of self-consistency between the apparent molar volumes and heat capacities at infinite dilution reported in this manuscript and those previously reported for aqueous rare earth perchlorates

  12. Thermodynamic properties of peptide solutions 20. Partial molar volumes and isothermal compressions for some tripeptides of sequence gly-X-gly (X = gly, ala, leu, asn, thr, and tyr) in aqueous solution at T = 298.15 K and p = (10–120) MPa

    International Nuclear Information System (INIS)

    Hedwig, Gavin R.; Høiland, Harald

    2016-01-01

    Highlights: • Sound speeds were measured for aqueous solutions of some tripeptides at high pressures. • Partial molar volumes and isothermal compressions were derived for T = 298.15 K and p = (10–120) MPa. • The partial molar volumes for non-polar amino acid side-chains decrease with increasing pressure. • The partial molar volumes for polar side-chains do not change significantly with increasing pressure. - Abstract: Sound speeds have been measured for aqueous solutions of six tripeptides of sequence glycyl-X-glycine, where X is one of the amino acids glycine, alanine, leucine, asparagine, threonine, and tyrosine at T = 298.15 K and at the pressures p = (10, 20, 40, 60, 80, 100, and 120) MPa. Using methods described in previous work, these sound speeds were used to derive the partial molar volumes at infinite dilution, V_2"o, the partial molar isentropic compressions at infinite dilution, K_S_,_2"o, and the partial molar isothermal compressions at infinite dilution, K"o_T_,_2 {K"o_T_,_2 = −(∂V_2"o/∂p)_T}, for the tripeptides in aqueous solution at the elevated pressures. The results were used to calculate the partial molar volumes and partial molar isothermal compressions for the various amino acid side-chains over the pressure range p = (10–120) MPa.

  13. A combined experimental and computational investigation of excess molar enthalpies of (nitrobenzene + alkanol) mixtures

    International Nuclear Information System (INIS)

    Neyband, Razieh Sadat; Zarei, Hosseinali

    2015-01-01

    Highlights: • Excess molar enthalpies for the binary mixtures of nitrobenzene + alkanols mixtures were measured. • The infinite dilution excess partial molar enthalpies were calculated using the ab initio methods. • The PCM calculations were performed. • The computed excess partial molar enthalpies at infinite dilution were compared to experimental results. - Abstract: Excess molar enthalpies (H m E ) for the binary mixtures of {(nitrobenzene + ethanol), 1-propanol, 2-propanol, 1-butanol and 2-butanol} have been measured over the entire composition range at ambient pressure (81.5 kPa) and temperature 298 K using a Parr 1455 solution calorimeter. From the experimental results, the excess partial molar enthalpies (H i E ) and excess partial molar enthalpies at infinite dilution (H i E,∞ ) were calculated. The excess molar enthalpies (H m E ) are positive for all {nitrobenzene (1) + alkanol (2)} mixtures over the entire composition range. A state-of-the-art computational strategy for the evaluation of excess partial molar enthalpies at infinite dilution was followed at the M05-2X/6-311++G ∗∗ level of theory with the PCM model. The experimental excess partial molar enthalpies at infinite dilution have been compared to the computational data of the ab initio in liquid phase. Integrated experimental and computational results help to clarify the nature of the intermolecular interactions in {nitrobenzene (1) + alkanol (2)} mixtures. The experimental and computational work which was done in this study complements and extends the general research on the computation of excess partial molar enthalpy at infinite dilution of binary mixtures

  14. Apparent molar heat capacities and apparent molar volumes of Pr(ClO4)3(aq), Gd(ClO4)3(aq), Ho(ClO4)3(aq), and Tm(ClO4)3(aq) at T=(288.15, 298.15, 313.15, and 328.15) K and p=0.1 MPa

    International Nuclear Information System (INIS)

    Hakin, Andrew W.; Lian Liu, Jin; Erickson, Kristy; Munoz, Julie-Vanessa

    2004-01-01

    Acidified aqueous solutions of Pr(ClO 4 ) 3 (aq), Gd(ClO 4 ) 3 (aq), Ho(ClO 4 ) 3 (aq), and Tm(ClO 4 ) 3 (aq) were prepared from the corresponding oxides by dissolution in dilute perchloric acid. Once characterized with respect to trivalent metal cation and acid content, the relative densities of the solutions were measured at T=(288.15, 298.15, 313.15, and 328.15) K and p=0.1 MPa using a Sodev O2D vibrating tube densimeter. The relative massic heat capacities of the aqueous systems were also determined, under the same temperature and pressure conditions, using a Picker Flow Microcalorimeter. All measurements were made on solutions containing rare earth salt in the concentration range 0.01 ≤ m/(mol · kg -1 ) ≤ 0.2. Relative densities and relative massic heat capacities were used to calculate the apparent molar volumes and apparent molar heat capacities of the acidified salt solutions from which the apparent molar properties of the aqueous salt solutions were extracted by the application of Young's Rule. The concentration dependences of the isothermal apparent molar volumes and heat capacities of each aqueous salt solution were modelled using Pitzer ion-interaction equations. These models produced estimates of apparent molar volumes and apparent molar heat capacities at infinite dilution for each set of isothermal V phi,2 and C pphi,2 values. In addition, the temperature and concentration dependences of the apparent molar volumes and apparent molar heat capacities of the aqueous rare earth perchlorate salt solutions were modelled using modified Pitzer ion-interaction equations. The latter equations utilized the Helgeson, Kirkham, and Flowers equations of state to model the temperature dependences (at p=0.1 MPa) of apparent molar volumes and apparent molar heat capacities at infinite dilution. The results of the latter models were compared to those previously published in the literature. Apparent molar volumes and apparent heat capacities at infinite dilution

  15. Predicting pathology in impacted mandibular third molars

    Directory of Open Access Journals (Sweden)

    Aveek Mukherji

    2017-01-01

    Full Text Available Introduction: The rising incidence of the impacted mandibular third molars and their association with pathologies is now considered a public health problem. Aims and Objectives: The objective of this study was to assess the position of impacted mandibular third molars that are prone to developing pathologies and to determine the frequency and type of pathological conditions associated with these impacted teeth to facilitate planning for their prophylactic removal. Materials and Methods: Consecutive panoramic radiographs and clinical examination of 300 patients with impacted mandibular third molars were collected. They were segregated according to Pell and Gregory’s classification, Winter’s classification, and according to their state of eruption. These were correlated with associated pathologies based on clinical and radiological criteria. Statistical Analysis Used: Descriptive statistics included computation of percentages, mean, and standard deviations. The statistical test applied for the analysis was Pearson’s Chi-square test (χ2. For this test, confidence interval and P value were set at 93% and ≤0.03, respectively. Results: The pathology most commonly associated with impacted third molars was pericoronitis, which had the highest frequency of occurrence in partially erupted, distoangular, and IA positioned (as per Pell and Gregory classification impacted teeth. Impacted mandibular third molars, which were in IA position, placed mesially, and partially erupted, were prone to develop pathologies such as dental caries and periodontitis. Conclusion: The clinical and radiographical features of impacted third molar may be correlated to the development of their pathological complications. The partially impacted mandibular third molars with mesioangularly aligned in IA position have the highest potential to cause pathological complications.

  16. 1. Thermochemical properties

    International Nuclear Information System (INIS)

    Rand, M.H.

    1975-01-01

    Thermodynamic properties (activity; molar heat capacity; free energy of reactions; partial molar free energy of solution; heat of reactions; heat of formation at 298 0 K; partial molar heat of solution; molar heat of evaporation, fusion, sublimation and transformation; standard entropy at 298 0 K; entropy of reactions; partial molar entropy of solution; molar entropy of evaporation, fusion, sublimation and transformation) of thorium, its compounds and binary alloy systems are reviewed

  17. Partial molar volumes of organic solutes in water. XXIII. Cyclic ketones at T = (298 to 573) K and pressures up to 30 MPa

    International Nuclear Information System (INIS)

    Cibulka, Ivan; Simurka, Lukas; Hnedkovsky, Lubomir; Bolotov, Alexander

    2011-01-01

    Research highlights: → In this study we examine standard molar volumes of aqueous cyclic ketones. → State parameters of measurements were (298 to 573) K and pressures up to 30 MPa. → Differences in behavior of monoketones and cyclohexane-1,4-dione were observed. → Group contribution method was designed and examined. - Abstract: Density data for dilute aqueous solutions of four cyclic ketones (cyclopentanone, cyclohexanone, cycloheptanone, and cyclohexane-1,4-dione) are presented together with standard molar volumes (partial molar volumes at infinite dilution) calculated from the experimental data. The measurements were performed at temperatures from T = 298 K up to T = 573 K. Experimental pressures were close to the saturated vapor pressure of water, and (15 and 30) MPa. The data were obtained using a high-temperature high-pressure flow vibrating-tube densimeter. Experimental standard molar volumes were correlated as a function of temperature and pressure using an empirical polynomial function. Contributions of the molecular structural segments (methylene and carbonyl groups) to the standard molar volume were also evaluated and analyzed.

  18. Effect of temperature on the partial molar volume, isentropic compressibility and viscosity of DL-2-aminobutyric acid in water and in aqueous sodium chloride solutions

    International Nuclear Information System (INIS)

    Romero, Carmen M.; Rodríguez, Diana M.; Ribeiro, Ana C.F.; Esteso, Miguel A.

    2017-01-01

    Highlights: • Apparent volumes, apparent compressibilities, viscosities of DL-2-aminobutyric acid. • Effect of temperature on the values for these properties. • Hydrophobic and hydrophilic interactions and the effect of sodium chloride. - Abstract: Density, sound velocity and viscosity of DL-2-aminobutyric acid in water and in aqueous sodium chloride solutions have been measured at temperatures of (293.15, 298.15, 303.15, 308.15 and 313.15) K. The experimental results were used to determine the apparent molar volume and the apparent molar compressibility as a function of composition at these temperatures. The limiting values of both the partial molar volume and the partial molar adiabatic compressibility at infinite dilution of DL-2-aminobutyric acid in water and in aqueous sodium chloride solutions were determined at each temperature. The experimental viscosity values were adjusted by a least-squares method to a second order equation as proposed by Tsangaris-Martin to obtain the viscosity B coefficient which depends on the size, shape and charge of the solute molecule. The influence of the temperature on the behaviour of the selected properties is discussed in terms of both the solute hydration and the balance between hydrophobic and hydrophilic interactions between the acids and water, and the effect of the sodium chloride concentration.

  19. Apparent molar volumes and apparent molar heat capacities of aqueous lead nitrate at temperatures from 278.15 K to 393.15 K and at the pressure 0.35 MPa

    International Nuclear Information System (INIS)

    Brown, B.R.; Niederhauser, T.L.; Merkley, E.D.; Woolley, E.M.

    2004-01-01

    Apparent molar volumes V phi and apparent molar heat capacities C p,phi were determined for aqueous solutions of lead nitrate [Pb(NO 3 ) 2 ] at m=(0.02 to 0.5) mol · kg -1 , at T=(278.15 to 393.15) K, and at the pressure 0.35 MPa. Our V phi values were calculated from densities obtained using a vibrating-tube densimeter, and our C p,phi values were obtained using a twin fixed-cell, power-compensation, differential-output, temperature-scanning calorimeter. Our results were fitted to functions of m and T and compared with results from the literature

  20. Low-temperature heat capacity and the standard molar enthalpy of formation of compound chromium(III) tri(pyrazine-2-carboxylate)

    International Nuclear Information System (INIS)

    Gao, Shengli; Zhang, Sheng; Chen, Sanping; Yang, Desuo

    2012-01-01

    Highlights: ► Low-temperature heat capacities of chromium(III) tri(pyrazine-2-carboxylate) were measured from 78 to 400 K. ► Thermodynamic functions of the compound at 298.15 K were calculated based on low-temperature heat capacity. ► The standard molar enthalpy of formation of the target was determined to be −1207.86 ± 3.39 kJ mol −1 through a designed thermochemical cycle. - Abstract: Low-temperature heat capacities of the coordination compound, chromium(III) tri(pyrazine-2-carboxylate), formulated as Cr(pyza) 3 (pyza = pyrazine-2-carboxylate), were measured by a precision automated adiabatic calorimeter over the temperature range of 78–400 K. A polynomial equation of heat capacities as a function of the temperature was fitted by the least square method. Based on the fitted polynomial equation, the fitted heat capacities and thermodynamic functions of the compound relative to the standard reference temperature 298.15 K were calculated at the interval of 5 K. In accordance with a reasonable thermochemical cycle designed, the standard molar enthalpy of formation of the title complex was determined to be −1207.86 ± 3.39 kJ mol −1 by an isoperibol solution–reaction calorimeter.

  1. Apparent molar volumes and apparent molar heat capacities of Pr(NO{sub 3}){sub 3}(aq), Gd(NO{sub 3}){sub 3}(aq), Ho(NO{sub 3}){sub 3}(aq), and Y(NO{sub 3}){sub 3}(aq) at T (288.15, 298.15, 313.15, and 328.15) K and p = 0.1 MPa

    Energy Technology Data Exchange (ETDEWEB)

    Hakin, Andrew W. [Department of Chemistry and Biochemistry, University of Lethbridge, 4401 University Drive, Lethbridge, Alberta, T1K 3M4 (Canada)]. E-mail: hakin@uleth.ca; Liu Jinlian [Department of Chemistry and Biochemistry, University of Lethbridge, 4401 University Drive, Lethbridge, Alberta, T1K 3M4 (Canada); Erickson, Kristy [Department of Chemistry and Biochemistry, University of Lethbridge, 4401 University Drive, Lethbridge, Alberta, T1K 3M4 (Canada); Munoz, Julie-Vanessa [Department of Chemistry and Biochemistry, University of Lethbridge, 4401 University Drive, Lethbridge, Alberta, T1K 3M4 (Canada); Rard, Joseph A. [Energy and Environment Directorate, Lawrence Livermore National Laboratory, University of California, Livermore, CA 94550 (United States)

    2005-02-01

    Relative densities and relative massic heat capacities have been measured for acidified solutions of Y(NO{sub 3}){sub 3}(aq), Pr(NO{sub 3}){sub 3}(aq), and Gd(NO{sub 3}){sub 3}(aq) at T = (288.15, 298.15, 313.15, and 328.15) K and p = 0.1 MPa. In addition, relative densities and massic heat capacities have been measured at the same temperatures and pressure for Y(NO{sub 3}){sub 3}(aq) and Ho(NO{sub 3}){sub 3}(aq) solutions without excess acid (n.b. measurements at T = 328.15 K for Ho(NO{sub 3}){sub 3}(aq) were not performed due to the limited volume of solution available). Apparent molar volumes and apparent molar heat capacities for the aqueous salt solutions have been calculated from the experimental apparent molar properties of the acidified solutions using Young's rule, whereas the apparent molar properties of the solutions without excess acid were calculated directly from the measured densities and massic heat capacities. The two sets of data for the Y(NO{sub 3}){sub 3}(aq) systems provide a check of the internal consistency of the Young's rule approach we have utilised. The concentration dependences of the apparent molar volumes and heat capacities of the aqueous salt solutions have been modelled at each investigated temperature using the Pitzer ion interaction equations to yield apparent molar properties at infinite dilution. Complex formation within the aqueous rare earth nitrate systems is discussed qualitatively by probing the concentration dependence of apparent molar volumes and heat capacities. In spite of the complex formation in the aqueous rare earth nitrate systems, there is a high degree of self-consistency between the apparent molar volumes and heat capacities at infinite dilution reported in this manuscript and those previously reported for aqueous rare earth perchlorates.

  2. Fast Computation of Solvation Free Energies with Molecular Density Functional Theory: Thermodynamic-Ensemble Partial Molar Volume Corrections.

    Science.gov (United States)

    Sergiievskyi, Volodymyr P; Jeanmairet, Guillaume; Levesque, Maximilien; Borgis, Daniel

    2014-06-05

    Molecular density functional theory (MDFT) offers an efficient implicit-solvent method to estimate molecule solvation free-energies, whereas conserving a fully molecular representation of the solvent. Even within a second-order approximation for the free-energy functional, the so-called homogeneous reference fluid approximation, we show that the hydration free-energies computed for a data set of 500 organic compounds are of similar quality as those obtained from molecular dynamics free-energy perturbation simulations, with a computer cost reduced by 2-3 orders of magnitude. This requires to introduce the proper partial volume correction to transform the results from the grand canonical to the isobaric-isotherm ensemble that is pertinent to experiments. We show that this correction can be extended to 3D-RISM calculations, giving a sound theoretical justification to empirical partial molar volume corrections that have been proposed recently.

  3. Molar development in sheep: morphology, radiography, microhardness

    International Nuclear Information System (INIS)

    Milhaud, G.; Nezit, J.

    1991-01-01

    The chronology of molar development is studied from radiographic and macroscopic observations on 48 south Pre-Alps were living under optimal nutritional conditions. It was found that the first molar started its development in utero, the second molar at one month after birth, and the third molar, at 9-10 months. The first molar emerged into the oral cavity at 3 months, the second at 9 months and the third molar at 18 months. The first molar began the development of its roots at 6-7 months, the second molar at 11-12 months and the third molar at 20-22 months. The first molar reached completion of the growth of its roots at 3.5-4 years, the second and the third molars at about 6 years. The molars show the particularity of being functional during the three months which follow their eruption although the development of the crown is not completed. Then the accelerated wear is only partially compensated by the growth of the roots. The study also shows how the combined effects of wear and dentine deposit in the pulp cavity affect the morphology of molars. It reveals the marked hardness of enamel (240 Vickers units) and the low resistance of dentine at the surface of attrition (30 Vickers units)

  4. The in vitro effect of Antimicrobial Photodynamic Therapy on dental microcosm biofilms from partially erupted permanent molars: A pilot study.

    Science.gov (United States)

    de Oliveira, Fabiana Sodré; Cruvinel, Thiago; Cusicanqui Méndez, Daniela Alejandra; Dionísio, Evandro José; Rios, Daniela; Machado, Maria Aparecida Andrade Moreira

    2018-03-01

    Antimicrobial Photodynamic Therapy (aPDT) could enhance the prevention of dental caries lesions in pits and fissures of partially erupted molars, by killing microorganisms from complex dental biofilms. This pilot study aimed to evaluate the effect of Antimicrobial Photodynamic Therapy (aPDT) on the viability of specific microorganism groups of dental microcosm biofilms from occlusal surfaces of first permanent molars in eruption. Dental microcosm biofilms grown on bovine enamel blocks, from dental plaque collected on occlusal surfaces of a partially erupted lower right first permanent molar, with McBain medium plus 1% sucrose in anaerobic condition at 37 °C for 72 h. The experiments were performed in eight groups: L-P- = no treatment (control), L18.75P- = 18.75 J/cm 2 LED, L37.5P- = 37.5 J/cm 2 LED, L75P- = 75 J/cm 2 LED, L-P+ = 200 mM TBO, L18.75P+ = 200 mM TBO + 18.75 J/cm 2 LED, L37.5P+ = 200 mM TBO + 37.5 J/cm 2 LED, and L75P+ = 200 mM TBO + 75 J/cm 2 LED. The counts of total microorganisms, total streptococci and mutans streptococci were determined on selective media agar plates by colony-forming units per mL. The log-transformed counts were analyzed by Kruskal-Wallis and post-hoc Dunn's test (P < 0.05). The counts of all microorganisms treated in the group L75P+ were statistically lower than those treated in L-P-. The aPDT promoted a significant reduction of microorganisms, with a trend of dose-dependent effect. TBO-mediated aPDT was effective in reducing the viability of specific microbial groups in dental microcosm biofilms originated from occlusal of permanent molars in eruption. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Experimental study of the density and derived volumetric (excess, apparent, and partial molar volumes) properties of aqueous 1-propanol mixtures at temperatures from 298 K to 582 K and pressures up to 40 MPa

    International Nuclear Information System (INIS)

    Abdulagatov, I.M.; Azizov, N.D.

    2014-01-01

    Highlights: • Density of (water + 1-propanol) mixtures. • Excess molar volumes of (water + 1-propanol) mixtures. • Apparent molar volumes of (water + 1-propanol) mixtures. -- Abstract: Densities of (water + 1-propanol) mixtures have been measured over the temperature range from 298 K to 582 K and at pressures up to 40 MPa using the constant-volume piezometer immersed in a precision liquid thermostat. The measurements were made for six compositions of (0.869, 2.465, 2.531, 7.407, 14.377, and 56.348) mol · kg −1 of 1-propanol. The expanded uncertainty of the density, pressure, temperature, and concentration measurements at the 95% confidence level with a coverage factor of k = 2 is estimated to be 0.06%, 0.05%, 15 mK, and 0.015%, respectively. The derived volumetric properties such as excess (V m E ), apparent (V Φ ), and partial (V ¯ 2 ∞ ) molar volumes were calculated using the measured values of density for the mixture and for pure components (water and 1-propanol). The concentration dependences of the apparent molar volumes were extrapolated to zero concentration to yield the partial molar volumes of 1-propanol at infinite dilution (V ¯ 2 ∞ ). The temperature, pressure, and concentration dependence of density and derived properties of the mixture were studied. All experimental and derived properties (excess, apparent, and partial molar volumes) were compared with the reported data by other authors. The small and negative values of excess molar volume for the mixtures were found at all experimental temperatures, pressures, and over the entire concentration range. The excess molar volume minimum is found at concentration about 0.4 mole fraction of 1-propanol. The concentration minimum of the derived apparent molar volumes V Φ near the 2.5 mol · kg −1 (dilute mixture) was observed

  6. Apparatus to measure vapor pressure, differential vapor pressure, liquid molar volume, and compressibility of liquids and solutions to the critical point. Vapor pressures, molar volumes, and compressibilities of protiobenzene and deuteriobenzene at elevated temperatures

    International Nuclear Information System (INIS)

    Kooner, Z.S.; Van Hook, W.A.

    1986-01-01

    An apparatus designed to measure vapor pressure differences between two similar liquids, such as isotopic isomers, or between a solution and its reference solvent at temperatures and pressures extending to the critical point is described. Vapor-phase volume is minimized and pressure is transmitted to the transducer through the liquid, thereby avoiding several experimental difficulties. Liquid can be injected into the heated part of the system by volumetrically calibrated screw injectors, thus permitting measurements of liquid molar volume, compressibility, and expansivity. The addition of a high-pressure circulating pump and injection valve allows the apparatus to be employed as a continuous dilution differential vapor pressure apparatus for determining partial molar free energies of solution. In the second part of the paper data on the vapor pressure, molar volume, compressibility, and expansivity and their isotope effects for C 6 H 6 and C 6 D 6 from room temperature to near the critical temperature are reported

  7. Apparent molar heat capacities and apparent molar volumes of Pr(ClO{sub 4}){sub 3}(aq), Gd(ClO{sub 4}){sub 3}(aq), Ho(ClO{sub 4}){sub 3}(aq), and Tm(ClO{sub 4}){sub 3}(aq) at T=(288.15, 298.15, 313.15, and 328.15) K and p=0.1 MPa

    Energy Technology Data Exchange (ETDEWEB)

    Hakin, Andrew W. E-mail: hakin@uleth.ca; Lian Liu, Jin; Erickson, Kristy; Munoz, Julie-Vanessa

    2004-09-01

    Acidified aqueous solutions of Pr(ClO{sub 4}){sub 3}(aq), Gd(ClO{sub 4}){sub 3}(aq), Ho(ClO{sub 4}){sub 3}(aq), and Tm(ClO{sub 4}){sub 3}(aq) were prepared from the corresponding oxides by dissolution in dilute perchloric acid. Once characterized with respect to trivalent metal cation and acid content, the relative densities of the solutions were measured at T=(288.15, 298.15, 313.15, and 328.15) K and p=0.1 MPa using a Sodev O2D vibrating tube densimeter. The relative massic heat capacities of the aqueous systems were also determined, under the same temperature and pressure conditions, using a Picker Flow Microcalorimeter. All measurements were made on solutions containing rare earth salt in the concentration range 0.01 {<=} m/(mol {center_dot} kg{sup -1}) {<=} 0.2. Relative densities and relative massic heat capacities were used to calculate the apparent molar volumes and apparent molar heat capacities of the acidified salt solutions from which the apparent molar properties of the aqueous salt solutions were extracted by the application of Young's Rule. The concentration dependences of the isothermal apparent molar volumes and heat capacities of each aqueous salt solution were modelled using Pitzer ion-interaction equations. These models produced estimates of apparent molar volumes and apparent molar heat capacities at infinite dilution for each set of isothermal V{sub phi,2} and C{sub pphi,2} values. In addition, the temperature and concentration dependences of the apparent molar volumes and apparent molar heat capacities of the aqueous rare earth perchlorate salt solutions were modelled using modified Pitzer ion-interaction equations. The latter equations utilized the Helgeson, Kirkham, and Flowers equations of state to model the temperature dependences (at p=0.1 MPa) of apparent molar volumes and apparent molar heat capacities at infinite dilution. The results of the latter models were compared to those previously published in the literature. Apparent

  8. Solvation molar enthalpies and heat capacities of n-alkanes and n-alkylbenzenes on stationary phases of wide-ranging polarity.

    Science.gov (United States)

    Lebrón-Aguilar, Rosa; Quintanilla-López, Jesús Eduardo; Santiuste, José María

    2010-12-03

    A comparison of the most usual gas chromatographic methods for the calculation of partial molar enthalpies of solvation (Δ(sol)H(o)) has been carried out. Those methods based on the fitting of lnV(g) or ln(k/T) vs. 1/T and ln(k/T) vs. (1/T and the temperature arrangement, T(a)) are the most adequate ones for obtaining Δ(sol)H(o) values. However, the latter is the only reliable option for Δ(sol)H(o) estimation when commercial WCOT capillary columns are used, since in this case the estimation of some variables involved in the V(g) determination is less accurate or even impossible. Consequently, in this paper, Δ(sol)H(o) obtained from ln(k/T) vs. (1/T+T(a)) fitting at 373.15 and 298.15K for n-alkanes and n-alkylbenzenes on 12 commercial capillary columns coated with stationary phases covering the 203-3608 McReynolds polarity range are reported. Moreover, molar heat capacities of solvation at constant pressure (Δ(sol)C(p)(o)) have also been calculated using this method. A clear influence on Δ(sol)H(o) of the type and content of the substitution group in the stationary phase was observed. In addition, a linear relationship of Δ(sol)C(p)(o) with the van der Waals volume of the n-alkanes and the temperature gradient of density of the stationary phase was found. The effect of the size of the hydrocarbon on both thermodynamic variables was also investigated. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Theoretical study of the partial molar volume change associated with the pressure-induced structural transition of ubiquitin.

    Science.gov (United States)

    Imai, Takashi; Ohyama, Shusaku; Kovalenko, Andriy; Hirata, Fumio

    2007-09-01

    The partial molar volume (PMV) change associated with the pressure-induced structural transition of ubiquitin is analyzed by the three-dimensional reference interaction site model (3D-RISM) theory of molecular solvation. The theory predicts that the PMV decreases upon the structural transition, which is consistent with the experimental observation. The volume decomposition analysis demonstrates that the PMV reduction is primarily caused by the decrease in the volume of structural voids in the protein, which is partially canceled by the volume expansion due to the hydration effects. It is found from further analysis that the PMV reduction is ascribed substantially to the penetration of water molecules into a specific part of the protein. Based on the thermodynamic relation, this result implies that the water penetration causes the pressure-induced structural transition. It supports the water penetration model of pressure denaturation of proteins proposed earlier.

  10. Partial molar volume of paracetamol in water, 0.1 M HCl and 0.154 M NaCl at T = (298.15, 303.15, 308.15 and 310.65) K and at 101.325 kPa

    Energy Technology Data Exchange (ETDEWEB)

    Iqbal, Muhammad Javed [Department of Chemistry, Quaid-i-Azam University, Islamabad, Capital 54320 (Pakistan)]. E-mail: mjiqauchem@yahoo.com; Malik, Qaisar Mahmood [Department of Chemistry, Quaid-i-Azam University, Islamabad, Capital 54320 (Pakistan)]. E-mail: qaisar_@hotmail.com

    2005-12-15

    The apparent molar volume of paracetamol (4-acetamidophenol) in water, 0.1 M HCl and 0.154 M NaCl as solvents at (298.15, 303.15, 308.15 and 310.65) K temperatures and at a pressure of 101.325 kPa were determined from the density data obtained with the help of a vibrating-tube Anton Paar DMA-48 densimeter. The partial molar volume, V {sub m}, of paracetamol in these solvents at different temperatures was evaluated by extrapolating the apparent molar volume versus molality plots to m = 0. In addition, the partial molar expansivity, E {sup .}, the isobaric coefficient of thermal expansion, {alpha} {sub p}, and the interaction coefficient, S {sub v}, have also been computed. The expansivity data show dependence of E {sup .} values on the structure of the solute molecules.

  11. Partial molar volume of paracetamol in water, 0.1 M HCl and 0.154 M NaCl at T = (298.15, 303.15, 308.15 and 310.65) K and at 101.325 kPa

    International Nuclear Information System (INIS)

    Iqbal, Muhammad Javed; Malik, Qaisar Mahmood

    2005-01-01

    The apparent molar volume of paracetamol (4-acetamidophenol) in water, 0.1 M HCl and 0.154 M NaCl as solvents at (298.15, 303.15, 308.15 and 310.65) K temperatures and at a pressure of 101.325 kPa were determined from the density data obtained with the help of a vibrating-tube Anton Paar DMA-48 densimeter. The partial molar volume, V m , of paracetamol in these solvents at different temperatures was evaluated by extrapolating the apparent molar volume versus molality plots to m = 0. In addition, the partial molar expansivity, E . , the isobaric coefficient of thermal expansion, α p , and the interaction coefficient, S v , have also been computed. The expansivity data show dependence of E . values on the structure of the solute molecules

  12. A Molar Pregnancy within the Fallopian Tube

    Directory of Open Access Journals (Sweden)

    Laura Allen

    2016-01-01

    Full Text Available Background. Discussion of the incidence of molar pregnancy and ectopic pregnancy. Role of salpingostomy and special considerations for postoperative care. Case. The patient is a 29-year-old G7P4 who presented with vaginal bleeding in the first trimester and was initially thought to have a spontaneous abortion. Ultrasound was performed due to ongoing symptoms and an adnexal mass was noted. She underwent uncomplicated salpingostomy and was later found to have a partial molar ectopic pregnancy. Conclusion. This case illustrates the rare occurrence of a molar ectopic pregnancy. There was no indication of molar pregnancy preoperatively and this case highlights the importance of submitting and reviewing pathological specimens.

  13. Apparent and partial molar volumes of long-chain alkyldimethylbenzylammonium chlorides and bromides in aqueous solutions at T=15 deg. C and T=25 deg. C

    International Nuclear Information System (INIS)

    Gonzalez-Perez, A.; Ruso, J.M.; Nimo, J.; Rodriguez, J.R.

    2003-01-01

    Density measurements of dodecyl- (C 12 DBACl), tetradecyl- (C 14 DBACl), hexadecyldimethylbenzylammonium chloride (C 16 DBACl) and of decyl- (C 10 DBABr) and dodecyldimethylbenzylammonium bromide (C 12 DBABr) in aqueous solutions at T=15 deg. C and T=25 deg. C have been carried out. From these results, apparent and partial molar volumes were calculated. Positive deviations from the Debye-Hueckel limiting law provide evidence for limited association at concentrations below the critical micelle concentration. The change of the apparent molar volume upon micellization was calculated. The relevant parameters have been presented in function of the alkyl chain length. Apparent molar volumes of the present compounds in the micellar phase, V phi m , and the change upon micellization, ΔV phi m , have been discussed in terms of temperature and type of counterion

  14. Association of the Mandibular Third Molar Position to the Pericoronitis

    Directory of Open Access Journals (Sweden)

    Tsvetan Tsvetanov

    2018-02-01

    Full Text Available Introduction: Pericoronitis is inflammation of the soft tissues surrounding the crown of a partially erupted tooth. Objective: To provide measurement of lower third molar angulation and determine relationship between mandibular third molar position and presence of pericoronitis. Material and methods: We studied 104 patients with lower third molar pericoronitis with clinical manifestations and measurement of lower third molar angulation. The mean age of patients was 25.7 years (range 18-35 years. Results: In this study was used the following statistical analysis, Pearson correlation coefficient and Spearman’s correlation coefficient (nonparametric version of the Pearson correlation coefficient for measure of the linear correlation between two variables - pericoronitis and angulation of the lower third molars. The chi-square test was used to assesses case incidences. The level of significance was p<0.05. 36.04% of partially impacted mandibular third molars were mesioangular followed by the vertical (25.47%, horizontal (18.97%, distoangular (9.21%, buccal (5.42% and lingual (3.79% position. The lowest part of the mandibular third molars is located in the ramus of mandible (1.08%. The present study was found in relation to mesioangular, distoangular, vertical impaction and pericoronitis (p<0.05. Conclusion: We conclude that the position of lower third molar may be able to be associated with presence of pericoronitis.

  15. Molecular analysis of 16S rRNA genes identifies potentially periodontal pathogenic bacteria and archaea in the plaque of partially erupted third molars.

    Science.gov (United States)

    Mansfield, J M; Campbell, J H; Bhandari, A R; Jesionowski, A M; Vickerman, M M

    2012-07-01

    Small subunit rRNA sequencing and phylogenetic analysis were used to identify cultivable and uncultivable microorganisms present in the dental plaque of symptomatic and asymptomatic partially erupted third molars to determine the prevalence of putative periodontal pathogens in pericoronal sites. Template DNA prepared from subgingival plaque collected from partially erupted symptomatic and asymptomatic mandibular third molars and healthy incisors was used in polymerase chain reaction with broad-range oligonucleotide primers to amplify 16S rRNA bacterial and archaeal genes. Amplicons were cloned, sequenced, and compared with known nucleotide sequences in online databases to identify the microorganisms present. Two thousand three hundred two clones from the plaque of 12 patients carried bacterial sequences from 63 genera belonging to 11 phyla, including members of the uncultivable TM7, SR1, and Chloroflexi, and difficult-to-cultivate Synergistetes and Spirochaetes. Dialister invisus, Filifactor alocis, Fusobacterium nucleatum, Porphyromonas endodontalis, Prevotella denticola, Tannerella forsythia, and Treponema denticola, which have been associated with periodontal disease, were found in significantly greater abundance in pericoronal compared with incisor sites. Dialister invisus and F nucleatum were found in greater abundance in sites exhibiting clinical symptoms. The archaeal species, Methanobrevibacter oralis, which has been associated with severe periodontitis, was found in 3 symptomatic patients. These findings have provided new insights into the complex microbiota of pericoronitis. Several bacterial and archaeal species implicated in periodontal disease were recovered in greater incidence and abundance from the plaque of partially erupted third molars compared with incisors, supporting the hypothesis that the pericoronal region may provide a favored niche for periodontal pathogens in otherwise healthy mouths. Copyright © 2012 American Association of Oral and

  16. Thermodynamic study of (heptane + amine) mixtures. III: Excess and partial molar volumes in mixtures with secondary, tertiary, and cyclic amines at 298.15 K

    International Nuclear Information System (INIS)

    Lepori, Luciano; Gianni, Paolo; Spanedda, Andrea; Matteoli, Enrico

    2011-01-01

    Graphical abstract: Highlights: → Excess volumes of (sec., tert., or cyclic amines + heptane) mixtures. → Excess volumes are positive for small size amines and decrease as the size increases. → Group contributions to predict the partial molar volumes of amines in heptane. → The void volume is larger for sec. and tert. than for linear amines in heptane. → The void volume is much smaller for cyclic than for linear amines in heptane. - Abstract: Excess molar volumes V E at 298.15 K were determined by means of a vibrating tube densimeter for binary mixtures of {heptane + open chain secondary (diethyl to dibutyl) and tertiary (triethyl to tripentyl) amines} as well as for cyclic imines (C 2 , C 3 , C 4 , C 6 , and C 7 ) and primary cycloalkylamines (C 5 , C 6 , C 7 , and C 12 ). The V E values were found positive for mixtures involving small size amines, with V E decreasing as the size increases. Negative V E 's were found for tributyl- and tripentylamine, heptamethylenimine, and cyclododecylamine. Mixtures of heptane with cycloheptylamine showed an s-shaped curve. Partial molar volumes V 0 of amines at infinite dilution in heptane were obtained from V E and compared with V 0 of hydrocarbons and other classes of organic compounds taken from literature. An additivity scheme, based on the intrinsic volume approach, was applied to estimate group (CH 3 , CH 2 , CH, C, NH 2 , NH, N, OH, O, CO, and COO) contributions to V 0 . These contributions, the effect of cyclization on V 0 , and the limiting slope of the apparent excess molar volumes were discussed in terms of solute-solvent and solute-solute interactions.

  17. Effectiveness of various sterilization methods of contaminated post-fitted molar band

    Directory of Open Access Journals (Sweden)

    Anggia Tridianti

    2013-06-01

    Full Text Available Background: Molar band as anchoring device may be contaminated during the fitting process. Thus, decontamination process is essential to prevent cross-infection between patients. Purpose: The objective of this research was to determine the amount of bacteria in molar band post-fitted on the patient teeth, after previously undergone pre-sterilization using alcohol and ultrasonic cleaning bath followed by sterilization using dry heat oven and steam autoclave, in order to find the best method in decontamination of post-fitted molar band. Methods: Four molar bands which already fitted on one patient then divided evenly into two groups. The first group was pre-sterilized using alcohol. One of the bands then sterilized using dry heat oven, while the other one was sterilized using steam autoclave. The second group was pre-sterilized using ultrasonic cleaning bath. One band from this group then sterilized using dry heat oven and the other was sterilized using steam autoclave. The next step was to immerse all the bands in a phosphate-buffered saline solution. Using micropipette, the solution was retrieved and dropped upon a petri dish containing Brain Heart Infusion broth. The dish was then stored in an incubator for 24 hours, prior to counting the number of bacteria existed. The same methods were used to the rest of the patients, with total 128 molar bands from 32 patients. Results: There was a profound difference in numbers of bacteria found between those methods of sterilization. However, there was a non significant difference between the two groups which were at the alcohol-steam autoclave group and at the ultrasonic cleaning bath-steam autoclave group. Conclusion: This study showed that steam autoclave is better than for sterilizing molar band, as it left the minimal amount of bacteria in post-fitted molar band.Latar belakang: Molar band merupakan suatu alat penjangkaran yang dapat mengalami kontaminasi selama proses fitting band, sehingga perlu

  18. Prevalence of missing and impacted third molars in adults aged 25 years and above

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yun Hoa; Cho, Bong Hae [Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Pusan National University, Yansan (Korea, Republic of)

    2013-12-15

    The purpose of this study was to determine the prevalence of missing and impacted third molars in people aged 25 years and above. The study sample of 3,799 patients was chosen randomly from patients who visited Pusan National University Dental Hospital and had panoramic radiographs taken. The data collected included presence and impaction state, angulation, and depth of impaction of third molars, and radiographically detected lesions of third molars and adjacent second molars. A greater percentage of men than women retained at least one third molar. The incidence of third molars decreased with increasing age. The incidence of partially impacted third molars greatly declined after the age of 30. Vertically impacted maxillary third molars and horizontally impacted mandibular third molars were most frequent in all age groups. Among the maxillary third molars, those impacted below the cervical line of the second molar were most frequent in all age groups, and among the mandibular third molars, deeply impacted third molars were most frequent in those aged over 40. Dental caries was the most common radiographic lesion of the third molars. Mesioangularly impacted third molars showed radiographic lesions in 13 (9.5%) adjacent maxillary second molars and 117 (27.4%) mandibular second molars. The number of remaining third molars decreased and the percentage of Class C depth increased with age. Caries was the most frequent lesion in third molars. Partially impacted mesioangular third molars showed a high incidence of caries or periodontal bone loss of the adjacent second molar. Regular oral examination will be essential to keep asymptomatic third molars in good health.

  19. Prevalence of missing and impacted third molars in adults aged 25 years and above

    International Nuclear Information System (INIS)

    Jung, Yun Hoa; Cho, Bong Hae

    2013-01-01

    The purpose of this study was to determine the prevalence of missing and impacted third molars in people aged 25 years and above. The study sample of 3,799 patients was chosen randomly from patients who visited Pusan National University Dental Hospital and had panoramic radiographs taken. The data collected included presence and impaction state, angulation, and depth of impaction of third molars, and radiographically detected lesions of third molars and adjacent second molars. A greater percentage of men than women retained at least one third molar. The incidence of third molars decreased with increasing age. The incidence of partially impacted third molars greatly declined after the age of 30. Vertically impacted maxillary third molars and horizontally impacted mandibular third molars were most frequent in all age groups. Among the maxillary third molars, those impacted below the cervical line of the second molar were most frequent in all age groups, and among the mandibular third molars, deeply impacted third molars were most frequent in those aged over 40. Dental caries was the most common radiographic lesion of the third molars. Mesioangularly impacted third molars showed radiographic lesions in 13 (9.5%) adjacent maxillary second molars and 117 (27.4%) mandibular second molars. The number of remaining third molars decreased and the percentage of Class C depth increased with age. Caries was the most frequent lesion in third molars. Partially impacted mesioangular third molars showed a high incidence of caries or periodontal bone loss of the adjacent second molar. Regular oral examination will be essential to keep asymptomatic third molars in good health.

  20. Lattice Boltzmann analysis of effect of heating location and Rayleigh number on natural convection in partially heated open ended cavity

    Energy Technology Data Exchange (ETDEWEB)

    Gangawane, Krunal Madhukar; Bharti, Ram Prakash; Kumar, Surendra [Indian Institute of Technology Roorkee, Uttarakhand (India)

    2015-08-15

    Natural convection characteristics of a partially heated open ended square cavity have been investigated numerically by using an in-house computational flow solver based on the passive scalar thermal lattice Boltzmann method (PS-TLBM) with D2Q9 (two-dimensional and nine-velocity link) lattice model. The partial part of left wall of the cavity is heated isothermally at either of the three different (bottom, middle and top) locations for the fixed heating length as half of characteristic length (H/2) while the right wall is open to the ambient conditions. The other parts of the cavity are thermally isolated. In particular, the influences of partial heating locations and Rayleigh number (103≤ Ra≤106) in the laminar zone on the local and global natural convection characteristics (such as streamline, vorticity and isotherm contours; centerline variations of velocity and temperature; and local and average Nusselt numbers) have been presented and discussed for the fixed value of the Prandtl number (Pr=0.71). The streamline patterns show qualitatively similar nature for all the three heating cases and Rayleigh numbers, except the change in the recirculation zone which is found to be largest for middle heating case. Isotherm patterns are shifted towards a partially heated wall on increasing Rayleigh number and/or shifting of heating location from bottom to top. Both the local and average Nusselt numbers, as anticipated, shown proportional increase with Rayleigh number. The cavity with middle heating location shown higher heat transfer rate than that for the top and bottom heating cases. Finally, the functional dependence of the average Nusselt number on flow governing parameters is also presented as a closure relationship for the best possible utilization in engineering practices and design.

  1. Apparent molar volumes and compressibilities of electrolytes and ions in γ-butyrolactone

    International Nuclear Information System (INIS)

    Krakowiak, Joanna; Wawer, Jarosław; Farmas, Aleksander

    2012-01-01

    Highlights: ► Density and speed of sound for salts solutions in γ-butyrolactone were measured. ► The apparent molar volumes and compressibilities have been determined. ► The limiting molar quantities are split into independent ionic contributions. ► These data are used to describe ion–solvent interactions. - Abstract: The densities of tetraphenylphosphonium bromide, sodium tetraphenylborate, lithium perchlorate, sodium perchlorate and lithium bromide in γ-butyrolactone at (288.15, 293.15, 298.15, 303.15, 308.15 and 313.15) K and speed of sound at 298.15 K have been measured. From these data apparent molar volumes V Φ at (288.15, 293.15, 298.15, 303.15, 308.15 and 313.15) K and the apparent molar isentropic compressibility K S,Φ , at T = 298.15 K of the salts have been determined. The apparent molar volumes and the apparent molar isentropic compressibilities were fitted to the Redlich, Rosenfeld and Mayer equation as well as to the Pitzer and Masson equations yielding infinite dilution data. The obtained limiting values have been used to estimate the ionic data of the standard partial molar volume and the standard partial isentropic compressibility in γ-butyrolactone solutions.

  2. Partial molar volumes of organic solutes in water. XXIV. Selected alkane-α,ω-diols at temperatures T = 298 K to 573 K and pressures up to 30 MPa

    International Nuclear Information System (INIS)

    Cibulka, Ivan; Hnědkovský, Lubomír

    2013-01-01

    Highlights: • Standard molar volumes of three alkane-α,ω-diols (C 5 , C 8 , C 9 ) in water are presented. • Data were obtained in the range T from (298 to 573) K and p up to 30 MPa. • Dependences on carbon atom number, temperature, and pressure are analysed. -- Abstract: Density data for dilute aqueous solutions of three alkane-α,ω-diols (pentane-1,5-diol, octane-1,8-diol, nonane-1,9-diol) are presented together with standard molar volumes (partial molar volumes at infinite dilution) calculated from the experimental data. The measurements were performed at temperatures from T = 298 K up to T = 573 K. Experimental pressures were slightly above the saturation vapour pressure of water, and (15 and 30) MPa. The data were obtained using a high-temperature high-pressure flow vibrating-tube densimeter. Measured standard molar volumes were combined with data previously published for other members of the homologous series and discussed. Experimental standard molar volumes were correlated as a function of temperature and pressure using an empirical polynomial function. Dependences of standard molar volumes on temperature and pressure were analysed. Contributions of the methylene group to the standard molar volume were also evaluated and discussed

  3. Prevalence of missing and impacted third molars in adults aged 25 years and above

    Science.gov (United States)

    Jung, Yun-Hoa

    2013-01-01

    Purpose The purpose of this study was to determine the prevalence of missing and impacted third molars in people aged 25 years and above. Materials and Methods The study sample of 3,799 patients was chosen randomly from patients who visited Pusan National University Dental Hospital and had panoramic radiographs taken. The data collected included presence and impaction state, angulation, and depth of impaction of third molars, and radiographically detected lesions of third molars and adjacent second molars. Results A greater percentage of men than women retained at least one third molar. The incidence of third molars decreased with increasing age. The incidence of partially impacted third molars greatly declined after the age of 30. Vertically impacted maxillary third molars and horizontally impacted mandibular third molars were most frequent in all age groups. Among the maxillary third molars, those impacted below the cervical line of the second molar were most frequent in all age groups, and among the mandibular third molars, deeply impacted third molars were most frequent in those aged over 40. Dental caries was the most common radiographic lesion of the third molars. Mesioangularly impacted third molars showed radiographic lesions in 13 (9.5%) adjacent maxillary second molars and 117 (27.4%) mandibular second molars. Conclusion The number of remaining third molars decreased and the percentage of Class C depth increased with age. Caries was the most frequent lesion in third molars. Partially impacted mesioangular third molars showed a high incidence of caries or periodontal bone loss of the adjacent second molar. Regular oral examination will be essential to keep asymptomatic third molars in good health. PMID:24380060

  4. Effect of partial heating at mid of vertical plate adjacent to porous medium

    Science.gov (United States)

    Mulla, Mohammed Fahimuddin; Pallan, Khalid. M.; Al-Rashed, A. A. A. A.

    2018-05-01

    Heat and mass transfer in porous medium due to heating of vertical plate at mid-section is analyzed for various physical parameters. The heat and mass transfer in porous medium is modeled with the help of momentum, energy and concentration equations in terms of non-dimensional partial differential equations. The partial differential equations are converted into simpler form of algebraic equations with the help of finite element method. A computer code is developed to assemble the matrix form of algebraic equations into global matrices and then to solve them in an iterative manner to obtain the temperature, concentration and streamline distribution inside the porous medium. It is found that the heat transfer behavior of porous medium heated at middle section is considerably different from other cases.

  5. Solubilities and partial molar volumes of N,N′-dibutyl-oxalamide, N,N′-dihexyl-oxalamide, N,N′-dioctyl-oxalamide in supercritical carbon dioxide

    International Nuclear Information System (INIS)

    Luo, Jie; Yang, Hai-Jian; Jin, Jing; Chang, Fei

    2012-01-01

    Highlights: ► Three new “CO 2 -philic” compounds were designed and synthesized. ► The tested solubility data were calculated and correlated with two models. ► Satisfactory agreements were obtained between the tested and calculated data. ► AARD was lower than 13% for Chrastil model correlation. ► The partial molar volumes V ¯ 2 for each compound were estimated. - Abstract: Three new potent CO 2 -philic compounds were synthesized and their structures were characterized by FT-IR, NMR, and elemental analysis. The solubility of the three compounds in supercritical CO 2 was determined at T = (313 to 353) K from 9.1 MPa to 15.0 MPa. The experimental data were correlated with two density-based models proposed by Bartle and Chrastil, and the calculated results showed good agreement with the tested data. The calculated data by Bartle model differed from the measured values by (6.76 to 9.60)%, and the average value of absolute relative deviations (AARD) with Chrastil model were observed to be between (7.42 to 12.27)%. Furthermore, solubility data were also utilized to estimate the partial molar volume V ¯ 2 for each compound in the supercritical phase using the theory developed by Kumar and Johnston.

  6. The Partial Molar Volume and Compressibility of FeO in CaO-SiO2 Liquids: Systematic Variation with Fe2+ Coordination Change

    Science.gov (United States)

    Guo, X.; Lange, R. A.; Ai, Y.

    2009-12-01

    Iron is an important element in magmatic liquid, since its concentration can range up to 18% in some basaltic liquids, and it has two oxidation states. In order to model magmatic processes, thermodynamic descriptions of silicate melts must include precise information for both the FeO and Fe2O3 components. Currently, the partial molar volume of FeO is not as well known as that for Fe2O3 because of the difficulty of performing double-bob density measurements under reducing conditions. Yet these data are required in order to convert sound speed measurements on FeO-bearing liquids into compressibility data, which in turn are needed extend density models for magmatic liquids to elevated pressures. Moreover, there is growing evidence from the spectroscopic literature that Fe2+ occurs in 4, 5, and 6-fold coordination in silicate melts, and thus it is possible that the partial molar volume and compressibility of FeO may vary with Fe2+ coordination, and thus with melt composition. To explore these issues, we have conducted both density and relaxed sound speed measurements on liquids in the CaO-FeO-SiO2 system, where the CaO/SiO2 ratio was systematically varied at constant FeO concentration (40 mol%). Density was measured between 1594 and 1813K with the double-bob Archimedean method using molybdenum bobs and crucible in a reducing gas (1%CO-99%Ar) environment. The sounds speeds were measured under similar conditions with a frequency-sweep acoustic interferometer. The derived partial molar volume of FeO increases systematically from 13.7 to 15.2 cm3/mol at 1673 K as the CaO/SiO2 ratio increases and the Fe2+ coordination number decreases. From a comparison with the crystalline volume of FeO (halite structure; 12.06 cm3/mol), which serves as a lower limit for VFeO in silicate liquids when Fe2+ is in 6-fold coordination, we estimate that the average Fe2+ coordination in our experimental melts extends up to values between 5 and 4, consistent with the spectroscopic literature. The

  7. Apparent molar volumes and compressibilities of lanthanum, gadolinium and lutetium trifluoromethanesulfonates in dimethylsulfoxide

    International Nuclear Information System (INIS)

    Warmińska, Dorota; Wawer, Jarosław

    2012-01-01

    Highlights: ► Sequence of volumes and compressibilities of Ln 3+ ions in DMSO is: La 3+ > Gd 3+ 3+ . ► Sequence of the partial molar volumes do not change with temperature. ► These results are the consequence of nature of the ion–solvent bonding. - Abstract: Temperature dependencies of the densities of dimethylsulfoxide solutions of lanthanum, gadolinium and lutetium trifluoromethanesulfonates have been determined over a wide range of concentrations. The apparent molar volumes and partial molar volumes of the salts at infinite dilution, as well as the expansibilities of the salts, have been calculated from density data. Additionally, the apparent molar isentropic compressibilities of lanthanum, gadolinium and lutetium trifluoromethanesulfonates have been calculated from sound velocity data at 298.15 K. The data obtained have been interpreted in terms of ion−solvent interactions.

  8. Buoyancy Effect of Ionic Vacancy on the Change of the Partial Molar Volume in Ferricyanide-Ferrocyanide Redox Reaction under a Vertical Gravity Field

    Directory of Open Access Journals (Sweden)

    Yoshinobu Oshikiri

    2013-01-01

    Full Text Available With a gravity electrode (GE in a vertical gravity field, the buoyancy effect of ionic vacancy on the change of the partial molar volume in the redox reaction between ferricyanide (FERRI and ferrocyanide (FERRO ions was examined. The buoyancy force of ionic vacancy takes a positive or negative value, depending on whether the rate-determining step is the production or extinction of the vacancy. Though the upward convection over an upward electrode in the FERRO ion oxidation suggests the contribution of the positive buoyancy force arising from the vacancy production, the partial molar volume of the vacancy was not measured. On the other hand, for the downward convection under a downward electrode in the FERRI ion reduction, it was not completely but partly measured by the contribution of the negative buoyancy force from the vacancy extinction. Since the lifetime of the vacancy is decreased by the collision between ionic vacancies during the convection, the former result was ascribed to the shortened lifetime due to the increasing collision efficiency in the enhanced upward convection over an upward electrode, whereas the latter was thought to arise from the elongated lifetime due to the decreasing collision efficiency by the stagnation under the downward electrode.

  9. Thermodynamics of proton dissociation from aqueous bicarbonate: apparent molar volumes and apparent molar heat capacities of potassium carbonate and potassium bicarbonate at T=(278.15 to 393.15) K and at the pressure 0.35 MPa

    International Nuclear Information System (INIS)

    Sorenson, E.C.; Woolley, E.M.

    2004-01-01

    We have determined the apparent molar volumes V phi and apparent molar heat capacities C p,phi of aqueous potassium carbonate and potassium bicarbonate solutions in the ranges (0.014≤m/(mol · kg -1 )≤0.51) and (278.15≤T/K≤393.15) at the pressure p=0.35 MPa. Corrections for speciation due to hydrolysis and disproportionation in solution were applied using Young's rule, and semi-empirical equations representing (V phi ,m,T) and (C p,phi ,m,T) for the species {2K + , CO 3 2- (aq)} and {K + , HCO 3 - (aq)} were fitted to the experimental results. We have used these equations to estimate the change in volume Δ r V m , change in heat capacity Δ r C p,m , enthalpy change Δ r H m , entropy change Δ r S m , and equilibrium molality quotient pQ for the second proton dissociation reaction from aqueous carbonic acid

  10. Intrinsic alterations in the partial molar volume on the protein denaturation: surficial Kirkwood-Buff approach.

    Science.gov (United States)

    Yu, Isseki; Takayanagi, Masayoshi; Nagaoka, Masataka

    2009-03-19

    The partial molar volume (PMV) of the protein chymotrypsin inhibitor 2 (CI2) was calculated by all-atom MD simulation. Denatured CI2 showed almost the same average PMV value as that of native CI2. This is consistent with the phenomenological question of the protein volume paradox. Furthermore, using the surficial Kirkwood-Buff approach, spatial distributions of PMV were analyzed as a function of the distance from the CI2 surface. The profiles of the new R-dependent PMV indicate that, in denatured CI2, the reduction in the solvent electrostatic interaction volume is canceled out mainly by an increment in thermal volume in the vicinity of its surface. In addition, the PMV of the denatured CI2 was found to increase in the region in which the number density of water atoms is minimum. These results provide a direct and detailed picture of the mechanism of the protein volume paradox suggested by Chalikian et al.

  11. Effect of two dimensional heat conduction within the wall on heat transfer of a tube partially heated on its circumference

    International Nuclear Information System (INIS)

    Satoh, Isao; Kurosaki, Yasuo

    1987-01-01

    This paper dealt with the numerical calculations of the heat transfer of a tube partially heated on its circumference, considering two-dimensional heat conduction within the wall. The contribution of the unheated region of the tube wall to heat tranfer of the heated region was explained by the term of 'fin efficiency of psuedo-fin', it was clarified that the fin efficiency of the unheated region was little affected by the temperature difference between the inner and outer surfaces of the wall, and could be approximated by the fin efficency of a rectangular fin. Both the circumferential and radial heat conductions within the wall affected the temperature difference between the inner and outer surfaces of the heated region; however, the effect of the temperature difference on the circumferentially average Nusselt number could be obtained by using the analytical solution of radially one-dimensional heat conduction. Using these results, a diagram showing the effect of wall conduction on heat transfer, which is useful for designing the circumferentially nonuniformly heated coolant passages, was obtained. (author)

  12. The Partial Molar Volume and Thermal Expansivity of Fe2O3 in Alkali Silicate Liquids: Evidence for the Average Coordination of Fe3+

    Science.gov (United States)

    Liu, Q.; Lange, R.

    2003-12-01

    Ferric iron is an important component in magmatic liquids, especially in those formed at subduction zones. Although it has long been known that Fe3+ occurs in four-, five- and six-fold coordination in crystalline compounds, only recently have all three Fe3+ coordination sites been confirmed in silicate glasses utilizing XANES spectroscopy at the Fe K-edge (Farges et al., 2003). Because the density of a magmatic liquid is largely determined by the geometrical packing of its network-forming cations (e.g., Si4+, Al3+, Ti4+, and Fe3+), the capacity of Fe3+ to undergo composition-induced coordination change affects the partial molar volume of the Fe2O3 component, which must be known to calculate how the ferric-ferrous ratio in magmatic liquids changes with pressure. Previous work has shown that the partial molar volume of Fe2O3 (VFe2O3) varies between calcic vs. sodic silicate melts (Mo et al., 1982; Dingwell and Brearley, 1988; Dingwell et al., 1988). The purpose of this study is to extend the data set in order to search for systematic variations in VFe2O3 with melt composition. High temperature (867-1534° C) density measurements were performed on eleven liquids in the Na2O-Fe2O3-FeO-SiO2 (NFS) system and five liquids in the K2O-Fe2O3-FeO-SiO2 (KFS) system using Pt double-bob Archimedean method. The ferric-ferrous ratio in the sodic and potassic liquids at each temperature of density measurement were calculated from the experimentally calibrated models of Lange and Carmichael (1989) and Tangeman et al. (2001) respectively. Compositions range (in mol%) from 4-18 Fe2O3, 0-3 FeO, 12-39 Na2O, 25-37 K2O, and 43-78 SiO2. Our density data are consistent with those of Dingwell et al. (1988) on similar sodic liquids. Our results indicate that for all five KFS liquids and for eight of eleven NFS liquids, the partial molar volume of the Fe2O3 component is a constant (41.57 ñ 0.14 cm3/mol) and exhibits zero thermal expansivity (similar to that for the SiO2 component). This value

  13. Fate of third molar in line of mandibular angle fracture - Retrospective study

    Directory of Open Access Journals (Sweden)

    Preetha Balaji

    2015-01-01

    Conclusion: The present study fails to identify any concrete factors that would predict the failure of the retained third molar that were involved in the line of mandibular fractures. The proof presented here, especially with low complication rates indicate that all impacted third molar along the line of fracture be removed and unless necessary, the partially erupted teeth would also be extracted. In such a situation, the rate of infection and survival of the third molar would have been entirely different.

  14. Excess molar volumes and isentropic compressibilities of binary ...

    Indian Academy of Sciences (India)

    Excess molar volume; binary liquid mixtures; isentropic compressibility; intermolecular interactions. ... mixtures are essential for fluid flow, mass flow and heat transfer processes in chemical ... Experimentally determined values of density(ρ).

  15. Low-temperature heat capacities and standard molar enthalpy of formation of 4-(2-aminoethyl)-phenol(C8H11NO)

    Institute of Scientific and Technical Information of China (English)

    Di You-Ying; Kong Yu-Xia; Yang Wei-Wei; Tan Zhi-Cheng

    2008-01-01

    This paper reports that low-temperature heat capacities of 4-(2-aminoethyl)-phenol(C8H11NO)are measured by a precision automated adiabatic calorimeter over the temperature range from 78 to 400 K.A polynomial equation of heat capacities as a function of the temperature was fitted by the least square method.Based on the fitted polynomial,the smoothed heat capacities and thermodynamic functions of the compound relative to the standard reference temperature 298.15 K were calculated and tabulated at the interval of 5 K.The energy equivalent,gcalor,of the oxygen-bomb The constant-volume energy of combustion of the compound at T=298.15 K was measured by a precision oxygen-bomb combustion and other thermodynamic principles.Finally,the standard molar enthalpy of formation of the compound

  16. Apparent molar volumes and apparent molar heat capacities of aqueous adonitol, dulcitol, glycerol, meso-erythritol, myo-inositol, D-sorbitol, and xylitol at temperatures from (278.15 to 368.15) K and at the pressure 0.35 MPa

    Energy Technology Data Exchange (ETDEWEB)

    Blodgett, M.B. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602-5700 (United States); Ziemer, S.P. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602-5700 (United States); Brown, B.R. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602-5700 (United States); Niederhauser, T.L. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602-5700 (United States); Woolley, E.M. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602-5700 (United States)]. E-mail: earl_woolley@byu.edu

    2007-04-15

    Apparent molar volumes V {sub {phi}} were determined for aqueous adonitol, dulcitol, glycerol, meso-erythritol, myo-inositol, D-sorbitol, and xylitol at temperatures from (278.15 to 368.15) K and at the pressure 0.35 MPa, and apparent molar heat capacities C {sub p,{phi}} of the same solutions were determined at temperatures from (278.15 to 363.15) K at the same pressure. Molalities m/(mol . kg{sup -1}) of the solutions were in the range (0.02 {<=} m {<=} 3.2) for adonitol, (0.02 {<=} m {<=} 0.15) for dulcitol, (0.02 {<=} m {<=} 5.0) for glycerol, (0.02 {<=} m {<=} 3.0) for meso-erythritol, (0.02 {<=} m {<=} 0.5) for myo-inositol, (0.02 {<=} m {<=} 2.0) for D-sorbitol, and (0.02 {<=} m {<=} 2.7) for xylitol. A vibrating tube densimeter was used to obtain solution densities and a fixed-cell temperature scanning calorimeter was used to obtain heat capacities. Values of V {sub {phi}} and C {sub p,{phi}} for these sugar alcohols are discussed relative to one another and compared to values from the literature, where available.

  17. Efficacy of orally administered prednisolone versus partial endodontic treatment on pain reduction in emergency care of acute irreversible pulpitis of mandibular molars: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Kérourédan, Olivia; Jallon, Léonard; Perez, Paul; Germain, Christine; Péli, Jean-François; Oriez, Dominique; Fricain, Jean-Christophe; Arrivé, Elise; Devillard, Raphaël

    2017-03-28

    Irreversible pulpitis is a highly painful inflammatory condition of the dental pulp which represents a common dental emergency. Recommended care is partial endodontic treatment. The dental literature reports major difficulties in achieving adequate analgesia to perform this emergency treatment, especially in the case of mandibular molars. In current practice, short-course, orally administered corticotherapy is used for the management of oral pain of inflammatory origin. The efficacy of intraosseous local steroid injections for irreversible pulpitis in mandibular molars has already been demonstrated but resulted in local comorbidities. Oral administration of short-course prednisolone is simple and safe but its efficacy to manage pain caused by irreversible pulpitis has not yet been demonstrated. This trial aims to evaluate the noninferiority of short-course, orally administered corticotherapy versus partial endodontic treatment for the emergency care of irreversible pulpitis in mandibular molars. This study is a noninferiority, open-label, randomized controlled clinical trial conducted at the Bordeaux University Hospital. One hundred and twenty subjects will be randomized in two 1:1 parallel arms: the intervention arm will receive one oral dose of prednisolone (1 mg/kg) during the emergency visit, followed by one morning dose each day for 3 days and the reference arm will receive partial endodontic treatment. Both groups will receive planned complete endodontic treatment 72 h after enrollment. The primary outcome is the proportion of patients with pain intensity below 5 on a Numeric Scale 24 h after the emergency visit. Secondary outcomes include comfort during care, the number of injected anesthetic cartridges when performing complete endodontic treatment, the number of antalgic drugs and the number of patients coming back for consultation after 72 h. This randomized trial will assess the ability of short-term corticotherapy to reduce pain in irreversible

  18. Deciduous molar hypomineralization and molar incisor hypomineralization

    NARCIS (Netherlands)

    Elfrink, M.E.C.; ten Cate, J.M.; Jaddoe, V.W.V.; Hofman, A.; Moll, H.A.; Veerkamp, J.S.J.

    2012-01-01

    This study was embedded in the Generation R Study, a population-based prospective cohort study from fetal life until young adulthood. This study focused on the relationship between Deciduous Molar Hypomineralization (DMH) and Molar Incisor Hypomineralization (MIH). First permanent molars develop

  19. Phase equilibria and excess molar volumes of tetrahydrofuran (1) + deuterium oxide (2)

    International Nuclear Information System (INIS)

    Lejcek, P.; Matous, J.; Novak, J.P.; Pick, J.

    1975-01-01

    Vapour + liquid equilibrium at 313.15 and 333.15K, liquid + liquid equilibrium throughout the whole region of limited miscibility, and excess molar volumes at 298.15K have been studied for tetrahydrofuran + deuterium oxide. The mixtures show large positive deviations from Raoult's law and a closed loop of limited miscibility. The modified Redlich-Kister equation has been used for the correlation of the vapour + liquid equilibrium. The computation has been carried out according to a recently proposed procedure which makes it possible to obtain such constants of the correlation relation which are not inconsistent with physical reality, i.e. with the complete miscibility (partial delta 2 G/deltax 1 2 >0) under experimental conditions. Thermodynamic consistency was checked by the classical Redlich-Kister test and the one proposed by Ulrichson and Stevenson. Excess molar volumes are negative at all compositions with a point of inflexion in the water-rich region which indicates the extremes in partial molar volumes. (author)

  20. Measurement and correlation of excess molar volumes for mixtures of 1-propanol and aromatic hydrocarbons

    International Nuclear Information System (INIS)

    Gahlyan, Suman; Rani, Manju; Maken, Sanjeev Kumar; Lee, Inkyu; Moon, Il

    2015-01-01

    Excess molar volumes (V m E ) have been measured at 303.15 K for 1-propanol+benzene or toluene or o- or m- or p-xylene mixtures using V-shape dilatometer. The V m E values, for an equimolar composition, vary in the order: benzene>toluene-m-xylene>o-xylene>p-xylene. The V m E data have been used to calculate partial molar volumes, excess partial molar volumes, and apparent molar volumes of 1-propanol and aromatic hydrocarbons over the entire range of composition. The excess volume data have also been interpreted in terms of graph-theoretical approach and Prigogine-Flory-Patterson theory (PFP). While PFP theory fails to predict the V m E values for systems with s-shaped V m E versus x 1 graph, the V m E values calculated by graph theory compare reasonably well with the corresponding experimental values. This graph theory analysis has further yielded information about the state of aggregation of pure components as well as of the mixtures

  1. Solubility comparison and partial molar volumes of 1,2-hexanediol before and after end-group modification by methyl oxalyl chloride and ethyl oxalyl monochloride in supercritical CO2

    International Nuclear Information System (INIS)

    Zhao, Lu; Yang, Hai-Jian; Cai, Zhuofu

    2013-01-01

    Highlights: ► Two new “CO 2 -philic” compounds were designed and synthesized. ► The tested solubility data were calculated and correlated with two models. ► Satisfactory agreements were obtained between the tested and calculated data. ► The partial molar volumes V ¯ 2 for three compounds were estimated. - Abstract: Bis(methoxy oxalic)-1,2-haxenediester and bis(ethoxy oxalic)-1,2-haxenediester were synthesized by modifying the end groups of 1,2-hexanediol with methyl oxalyl chloride and ethyl oxalyl monochloride. The solubilities of all three compounds in supercritical carbon dioxide were determined at different conditions of pressures (8.8 to 18.8) MPa and temperatures (313, 333, and 353) K. Then, the solubility data were correlated with the Bartle model and the Chrastil model. The average absolute relative deviation (AARD) for the Bartle model was in the range of (3.89 to 25.46)% which is within a good approximation. The Chrastil model also showed satisfactory agreement and the AARD was in the range of (3.70 to 16.92)%. Furthermore, the partial molar volumes of those compounds were estimated following the theory developed by Kumar and Johnston.

  2. Application of ERAS-model and Prigogine-Flory-Patterson theory to excess molar volumes for ternary mixtures of (2-chlorobutane + butylacetate + isobutanol) at T = 298.15 K

    International Nuclear Information System (INIS)

    Khanlarzadeh, K.; Iloukhani, H.

    2011-01-01

    Highlights: → Density of ternary and three binary mixtures of (2-chlorobutane + butylacetate + isobutanol) determined. → Excess molar volume, partial molar volume and apparent molar volume were calculated. → Excess molar volume was correlated as a function of mole fraction by using the Redlich-Kister and Cibulka equation for all mixtures. → The experimental results have been used to test the applicability of the ERAS-model and PFP theory. - Abstract: Densities of the ternary mixture consisting of {2-chlorobutane (1) + butylacetate (2) + isobutanol (3)} and related binary mixtures were measured over the whole range of composition at T = 298.15 K and ambient pressure. Excess molar volumes V m E for the mixtures were derived and correlated as a function of mole fraction by using the Redlich-Kister and the Cibulka equations for binary and ternary mixtures, respectively. From the experimental data, partial molar volumes, V-bar m,i excess partial molar volumes, V-bar i E partial molar volumes at infinite dilution V-bar m,i 0 and apparent molar volumes V-bar φ,i were also calculated. For all binary mixtures over the entire range of mole fractions V m E data are positive. The experimental results of the constituted binary mixtures have been used to test the applicability of the extended real associated solution (ERAS-model) and Prigogine-Flory-Paterson (PFP) theory.

  3. Apparent molar volumes and apparent molar heat capacities of aqueous adonitol, dulcitol, glycerol, meso-erythritol, myo-inositol, D-sorbitol, and xylitol at temperatures from (278.15 to 368.15) K and at the pressure 0.35 MPa

    International Nuclear Information System (INIS)

    Blodgett, M.B.; Ziemer, S.P.; Brown, B.R.; Niederhauser, T.L.; Woolley, E.M.

    2007-01-01

    Apparent molar volumes V φ were determined for aqueous adonitol, dulcitol, glycerol, meso-erythritol, myo-inositol, D-sorbitol, and xylitol at temperatures from (278.15 to 368.15) K and at the pressure 0.35 MPa, and apparent molar heat capacities C p,φ of the same solutions were determined at temperatures from (278.15 to 363.15) K at the same pressure. Molalities m/(mol . kg -1 ) of the solutions were in the range (0.02 ≤ m ≤ 3.2) for adonitol, (0.02 ≤ m ≤ 0.15) for dulcitol, (0.02 ≤ m ≤ 5.0) for glycerol, (0.02 ≤ m ≤ 3.0) for meso-erythritol, (0.02 ≤ m ≤ 0.5) for myo-inositol, (0.02 ≤ m ≤ 2.0) for D-sorbitol, and (0.02 ≤ m ≤ 2.7) for xylitol. A vibrating tube densimeter was used to obtain solution densities and a fixed-cell temperature scanning calorimeter was used to obtain heat capacities. Values of V φ and C p,φ for these sugar alcohols are discussed relative to one another and compared to values from the literature, where available

  4. Group additivity values for enthalpies of formation (298 K), entropies (298 K), and molar heat capacities (300 K < T < 1500 K) of gaseous fluorocarbons

    International Nuclear Information System (INIS)

    Van Otterloo, Maren K.; Girshick, Steven L.; Roberts, Jeffrey T.

    2007-01-01

    A group additivity method was developed to estimate standard enthalpies of formation and standard entropies at 298 K of linear radical and closed-shell, gaseous fluorocarbon neutrals containing four or more carbon atoms. The method can also be used to estimate constant pressure molar heat capacities of the same compounds over the temperature range 300 K to 1500 K. Seventeen groups and seven fluorine-fluorine interaction terms were defined from 12 fluorocarbon molecules. Interaction term values from Yamada and Bozzelli [T. Yamada, J.W. Bozzelli, J. Phys. Chem. A 103 (1999) 7373-7379] were utilized. The enthalpy of formation group values were derived from G3MP2 calculations by Bauschlicher and Ricca [C.W. Bauschlicher, A. Ricca, J. Phys. Chem. A 104 (2000) 4581-4585]. Standard entropy and molar heat capacity group values were estimated from ab initio geometry optimization and frequency calculations at the Hartree-Fock level using the 6-31G(d) basis set. Enthalpies of formation for larger fluorocarbons estimated from the group additivity method compare well to enthalpies of formation found in the literature

  5. Densities, molar volumes, and isobaric expansivities of (d-xylose+hydrochloric acid+water) systems

    International Nuclear Information System (INIS)

    Zhang Qiufen; Yan Zhenning; Wang Jianji; Zhang Hucheng

    2006-01-01

    Densities of (d-xylose+HCl+water) have been measured at temperature in the range (278.15 to 318.15) K as a function of concentration of both d-xylose and hydrochloric acid. The densities have been used to estimate the molar volumes and isobaric expansivity of the ternary solutions. The molar volumes of the ternary solutions vary linearly with mole fraction of d-xylose. The standard partial molar volumes V 2,φ - bar for d-xylose in aqueous solutions of molality (0.2, 0.4, 0.7, 1.1, 1.6, and 2.1) mol.kg -1 HCl have been determined. In the investigated temperature range, the relation: V 2,φ - bar =c 1 +c 2 {(T/K)-273.15} 1/2 , can be used to describe the temperature dependence of the standard partial molar volumes. These results have, in conjunction with the results obtained in water, been used to deduce the standard volumes of transfer, Δ t V - bar , of d-xylose from water to aqueous HCl solutions. An increase in the transfer volume of d-xylose with increasing HCl concentrations has been explained by the stronger interactions of H + with the hydrophilic groups of d-xylose

  6. 二氧化碳与2-丁醇二元体系在高压下的亨利系数和偏摩尔体积性质计算%Calculation of Henry's coefficient and partial molar volume of carbon dioxide in 2-butanol at elevated pressures

    Institute of Scientific and Technical Information of China (English)

    田爱琴; 孙洪博; 陈文涛; 王琳

    2012-01-01

    Based on vapor-liquid phase equilibria data for CO2+2-butanol binary system from 323K to 353K by constant-volume visual high-pressure cell, the solubility model of CO2 in 2-butanol was established with Krichevsky-Kasarnovsky equation. Henry's coefficients and partial molar volumes of CO2 at infinite dilution were calculated. Meanwhile, Partial molar volumes of CO2 and 2-butanol at equilibrium were calculated from partial molar volumes properties together with Peng-Robinson equation of state and Van der Waals-2 mixed rule. The results showed that Henry's coefficients and partial molar volumes of CO2 at infinite dilution were both the function of temperature, and Henry's coefficients decreased with temperature. The partial molar volumes of CO2 at infinite dilution were negative and the magnitudes decreased with temperature. The calculated effects of partial molar volumes of vapor and liquid phase at equilibrium showed that the partial molar volumes of CO2 and 2-butanol in liquid phase were positive, but in vapor the partial molar volumes of CO2 were negative and the partial molar volumes of 2-butanol were positive. The research provided theoretical basis for deciding supercritical extraction conditions and instructing industrial production.%利用固定体积可视高压釜测量出的在323 K~353 K温度范围内的CO2与2-丁醇二元体系在高压下的汽液相平衡数据,根据Krichevsky-Kasarnovsky方程建立了CO2在液相中的溶解度模型,得到了该二元体系在高压下的亨利系数和CO2在无限稀释溶液中的偏摩尔体积等性质.同时根据偏摩尔体积性质和Peng-Robinson状态方程及Van der Waals-2混合规则来计算该体系在平衡状态下的气、液相的偏摩尔体积.结果表明CO2在2-丁醇中的亨利系数和CO2在无限稀释溶液中的偏摩尔体积均为温度的函数,CO2在2-丁醇中的亨利系数随温度的升高而降低.CO2在无限稀释溶液中的偏摩尔体积(V)1

  7. [Surgery of lower third molars and lesions of the lingual nerve].

    Science.gov (United States)

    Chiapasco, M; Pedrinazzi, M; Motta, J; Crescentini, M; Ramundo, G

    1996-11-01

    The authors describe a technical expedient applied during the removal of totally or partially impacted lower third molars, in order to prevent lingual nerve damage. EXPERIMENTAL ASSAY: Retrospective study. The sample includes 1835 extractions of totally or partially impacted lower third molars, performed on 1030 patients, 493 males and 537 females, aging between 12 and 72 years. All the operations were carried out under local anaesthesia with standardization of the surgical protocol. A mucoperiosteal paramarginal flap was used in case of germectomy, whereas a mucoperiosteal marginal flap with mesial releasing incision was used in case of fully mature teeth. Ostectomy and tooth sectioning were performed using a round and fissure bur respectively, assembled on a straight low-speed handpiece and under irrigation with sterile saline. The authors reported only one case of transient lingual nerve paresthesia (0.05%) which occurred in a 19-years old female presenting a totally impacted third molar mesial-lingual inclination. Symptoms disappeared spontaneously one week postoperatively. Therefore the overall incidence of permanent nerve damage was equal to 0%. The data reported in literature show a lingual nerve lesion incidence ranging between 0% and 22%. With this simple surgical expedient the incidence of permanent lingual damage was 0%. Thus, it is the authors' opinion that this simple expedient should be applied in all cases of impacted third molar removal.

  8. Treatment of ectopically erupting maxillary permanent first molars with a distal extended stainless steel crown.

    Science.gov (United States)

    Roberts, M W

    1986-01-01

    The exaggerated mesial eruption of the permanent first molar can result in the tooth becoming impacted, or the premature atypical resorption and exfoliation of the primary molar, with a resultant loss of space. A stainless steel crown with a distal guide plane was placed on a primary molar to correct the aberrant eruption angle of the permanent tooth. This procedure can be used successfully for both partially and totally tissue-impacted teeth, and is described in this report.

  9. Measurement and correlation of excess molar volumes for mixtures of 1-propanol and aromatic hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Gahlyan, Suman; Rani, Manju; Maken, Sanjeev Kumar [Deenbandhu Chhotu Ram University of Science and Technology, Murthal (India); Lee, Inkyu; Moon, Il [Yonsei University, Seoul (Korea, Republic of)

    2015-01-15

    Excess molar volumes (V{sub m}{sup E} ) have been measured at 303.15 K for 1-propanol+benzene or toluene or o- or m- or p-xylene mixtures using V-shape dilatometer. The V{sub m}{sup E} values, for an equimolar composition, vary in the order: benzene>toluene-m-xylene>o-xylene>p-xylene. The V{sub m}{sup E} data have been used to calculate partial molar volumes, excess partial molar volumes, and apparent molar volumes of 1-propanol and aromatic hydrocarbons over the entire range of composition. The excess volume data have also been interpreted in terms of graph-theoretical approach and Prigogine-Flory-Patterson theory (PFP). While PFP theory fails to predict the V{sub m}{sup E} values for systems with s-shaped V{sub m}{sup E} versus x{sub 1} graph, the V{sub m}{sup E} values calculated by graph theory compare reasonably well with the corresponding experimental values. This graph theory analysis has further yielded information about the state of aggregation of pure components as well as of the mixtures.

  10. Apparent molar volumes and compressibilities of alkaline earth metal ions in methanol and dimethylsulfoxide

    International Nuclear Information System (INIS)

    Warminska, Dorota; Wawer, Jaroslaw; Grzybkowski, Waclaw

    2010-01-01

    Temperature dependencies of density of magnesium (II), calcium (II), strontium (II), barium (II) perchlorates as well as beryllium (II), and sodium trifluoromethanesulfonates in methanol and dimethylsulfoxide have been determined over the composition range studied. From density data the apparent molar volumes and partial molar volumes of the salts at infinite dilution as well as the expansibilities have been evaluated. The apparent molar isentropic compressibilities of alkaline earth metal perchlorates and beryllium (II) and sodium triflates in methanol and DMSO have been calculated from sound speed data obtained at T = 298.15 K.

  11. Excess Molar Volume,Viscosity and Heat Capacity for the Mixture of 1,2—Propanediol—Water at Different Temperatures

    Institute of Scientific and Technical Information of China (English)

    杨长生; 马沛生; 唐多强; 靳凤民

    2003-01-01

    Experimental densities,viscosities and heat capacities at different emperatures were presented over the entire mole fraction range for the binary mixture of 1,2-propanediol and water,Density values were used in the determination of excess molar volumes,VE,At the same time,the excess viscosity was in vestigated,The values of VE and ηE were fitted to the Redlich-kister equation.Good agreement was observed,The excess volumes are negative over the entire range of composition.They show an U-shaped-concentration dependence and decrease in abolute values with increase of temperature,Values of ηE are negative over the entire range of the composition,and has a trend very similar to that of VE ,The analysis shows that at any temperature the specific heat of mixture is a linear function of the composition as x1>20%,All the extended lines intersect at one point.An empirical equation is obtained to calculate the specific heat to mixture at any composition and temperature in the experimental range.

  12. INFORMATIVE THERMODYNAMIC PROPERTIES OF THE EFFECT OF STEREOCHEMISTRY ON CARBOHYDRATE HYDRATION

    NARCIS (Netherlands)

    GALEMA, SA; ENGBERTS, JBFN; HOILAND, H; FORLAND, GM

    1993-01-01

    Partial molar heat capacities of aqueous solutions of pentoses, hexoses, methyl aldoglycopyranosides, and some disaccharides as well as partial molar expansibilities and isothermal compressibilities of methyl aldoglycopyranosides in aqueous solution are reported. A comparison is made with partial

  13. 293.15 K到333.15 K温度下一些氨基酸及其相应基团水溶液中的偏摩尔体积研究%Studies on Partial Molar Volumes of Some Amino Acids and Their Groups in Aqueous Solutions from 293.15 K to 333.15 K

    Institute of Scientific and Technical Information of China (English)

    赵长伟; 马沛生; 夏淑倩

    2004-01-01

    Densities of aqueous solutions of eight amino acids, glycine, L-alanine, L-valine, L-isoleucine, L-serine,L-threonine, L-arginine and L-phenylalanine, are measured as a function of amino acid concentration from 293.15 K to 333.15K. These data are used to calculate the apparent molar volume V and infinite dilution apparent molar volume V0 (partial molar volume). Data of five amino acids are used to correlate partial molar volume V0 using group contribution method to estimate the contributions of the zwitterionic end groups (NH3+,COO-) and CH2group, OH group, CNHNHNH2 group and C6H5(phenyl) group of amino acids. The results show that V0 values for all kinds of groups of amino acids studied increase with increase of temperature except those for CH2 group,which are almost constant within the studied temperature range. Data of other amino acids, L-valine, L-isoleucine and L-threonine, are chosen for comparison with the predicted partial molar volume V0 using the group additivity parameters obtained. The results confirm that this group additivity method has excellent predictive utility.

  14. Molar concentration-depth profiles at the solution surface of a cationic surfactant reconstructed with angle resolved X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Wang Chuangye; Morgner, Harald

    2011-01-01

    In the current work, we first reconstructed the molar fraction-depth profiles of cation and anion near the surface of tetrabutylammonium iodide dissolved in formamide by a refined calculation procedure, based on angle resolved X-ray photoelectron spectroscopy experiments. In this calculation procedure, both the transmission functions of the core levels and the inelastic mean free paths of the photoelectrons have been taken into account. We have evaluated the partial molar volumes of surfactant and solvent by the densities of such solutions with different bulk concentrations. With those partial molar volumes, the molar concentration-depth profiles of tetrabutylammonium ion and iodide ion were determined. The surface excesses of both surfactant ions were then achieved directly by integrating these depth profiles. The anionic molar concentration-depth profiles and surface excesses have been compared with their counterparts determined by neutral impact ion scattering spectroscopy. The comparisons exhibit good agreements. Being capable of determining molar concentration-depth profiles of surfactant ions by core levels with different kinetic energies may extend the applicable range of ARXPS in investigating solution surfaces.

  15. MOLAR UPRIGHTING

    Directory of Open Access Journals (Sweden)

    Eka Erwansyah

    2006-04-01

    Full Text Available The mesial tipping of molar is frequently found in orthodontic cases. This molar malposition must be corrected since it may cause periodontal disorders, occlusal interferences, and temporomandibular joint dysfunction, and is often needed in planning a fixed bridge. This paper is a literature study to discuss about appliance designs, indication, and contraindications, and complication and treatment protocols of molar uprighting by fixed orthodontic appliances. By knowing the techniques of molar uprighting, the moments mentioned above can be avoided.

  16. Intrusion of an overerupted molar using orthodontic miniscrew implant: A preprosthodontic therapy

    Directory of Open Access Journals (Sweden)

    Indumathi Sivakumar

    2014-01-01

    Full Text Available The purpose of this case report is to demonstrate the use of orthodontic miniscrew implant in the intrusion of overerupted molar as a preprosthodontic therapy. A 37-year-old woman with an overerupted maxillary right first molar encroaching on the opposing mandibular edentulous space was successfully intruded using a single miniscrew implant and partial fixed orthodontic appliance. The prosthodontic clinician may adopt this conservative and cost-effective strategy in their routine practice and avoid clinical crown reduction.

  17. Apparent molar volumes and apparent molar heat capacities of aqueous tetrahydrofuran, dimethyl sulfoxide, 1,4-dioxane, and 1,2-dimethoxyethane at temperatures from 278.15 K to 393.15 K and at the pressure 0.35 MPa

    International Nuclear Information System (INIS)

    Swenson, D.M.; Blodgett, M.B.; Ziemer, S.P.; Woolley, E.M.

    2008-01-01

    We determined apparent molar volumes V φ at 278.15 ≤ (T/K) ≤ 368.15 and apparent molar heat capacities C p,φ at 278.15 ≤ (T/K) ≤ 393.15 at p = 0.35 MPa for aqueous solutions of tetrahydrofuran at m from (0.016 to 2.5) mol . kg -1 , dimethyl sulfoxide at m from (0.02 to 3.0) mol . kg -1 , 1,4-dioxane at m from (0.015 to 2.0) mol . kg -1 , and 1,2-dimethoxyethane at m from (0.01 to 2.0) mol . kg -1 . Values of V φ were determined from densities measured with a vibrating-tube densimeter, and values of C p,φ were determined with a twin fixed-cell, differential, temperature-scanning calorimeter. Empirical functions of m and T for each compound were fitted to our V φ and C p,φ results

  18. Fusión de un tercer molar mandibular con un cuarto molar supernumerario Fusion of mandibular third molar with supernumerary fourth molar

    Directory of Open Access Journals (Sweden)

    C. López Carriches

    2008-10-01

    Full Text Available La fusión dental es la unión de dos gérmenes dentales normalmente separados, mientras que la geminación se define como el intento de división de un único germen dental. La fusión y geminación de molares es poco frecuente en la dentición permanente. Describimos un caso clínico de un tercer molar inferior derecho fusionado a un cuarto molar supernumerario en un paciente varón de 36 años que ha presentado repetidos episodios de pericoronaritis. Tras el estudio radiológico se realiza la exodoncia del cordal semiincluido bajo anestesia local. Llevamos a cabo una revisión bibliográfica al respecto.Dental fusion is the union of two tooth buds that normally are separated, while gemination is defined as an attempt by a single tooth bud to divide. The fusion and gemination of molars is uncommon in permanent teeth. We report a clinical case of a right lower third molar fused to a supernumerary fourth molar in a 36-year-old male patient with repeated episodes of inflammation. After the radiologic study, the semi-impacted third molar was extracted under local anesthesia. The literature was reviewed.

  19. Hydrophobic hydration and anomalous excess partial molar volume of tert-butyl alcohol-water mixture studied by quasielastic neutron scattering

    International Nuclear Information System (INIS)

    Nakada, Masaru; Maruyama, Kenji; Misawa, Masakatsu; Yamamuro, Osamu

    2007-01-01

    Quasielastic neutron scattering has been used to investigate the hydration of alcohol clusters in tert-butyl alcohol-water mixture. The measurements were made in a range of alcohol concentration, x TBA , from 0.0 to 0.17 in mole fraction at 25degC. Fraction, α, of water molecules hydrated to fractal-surface of alcohol clusters in tert-butyl alcohol-water mixture was obtained as a function of alcohol concentration. Average hydration number N WS of tert-butyl alcohol molecule was derived from the value of α as a function of alcohol concentration. The value of N WS for an isolated alcohol molecule in water was 19-21. The anomalous excess partial molar volume of tert-butyl alcohol-water mixture was interpreted successfully by applying the same model with the same values of volume parameter as used for 1-propanol-water mixture, δ 1 (=-0.36 cm 3 ·mol -1 ) and δ 2 (=0.60 cm 3 ·mol -1 ). (author)

  20. AXIAL MODIFICATIONS OF PERMANENT LOWER MOLARS AFTER PREMATURE LOSSES OF TEMPORARY MOLARS.

    Science.gov (United States)

    Cernei, E R; Mavru, R B; Zetu, Irina Nicoleta

    2016-01-01

    The aim of our study was to determine the impact of premature loss of temporary lower molars upon the longitudinal axis of the first and second permanent molars. The study groups included 61 patients, 6-9 year olds with premature loss of primary molars and a control group of 24 patients with intact temporary teeth. We evaluated the angle between longitudinal axis of first and second lower permanent molars and occlusal plane. It was observed that premature loss of lower second deciduous molar modifies more the vertical axis of first and second permanent molars than the premature loss of first lower primary molar. Reducing space occurs mainly through mesial inclination of molars that separates the edentulous breach. Temporary loss of both lower first molars on the same quadrant causes an accelerated eruption of both premolars increasing the prevalence of eruption sequence: "4-5-3-7". The preservation of the occlusal morpho-functional complex using space maintainers mainly when the premature loss of the second primary molars occurs is the best interceptive treatment option.

  1. The influence of premature loss of temporary upper molars on permanent molars.

    Science.gov (United States)

    Cernei, E R; Maxim, Dana Cristiana; Zetu, Irina Nicoleta

    2015-01-01

    Premature loss of primary molars due to dental caries and their complications has been associated with space loss and eruptive difficulties, especially when the loss occurs early. The aim of our study was to determine the impact of premature loss of temporary upper molars upon the longitudinal axis of the first and second upper permanent molar. The study group included 64 patients 6-9 years old with premature loss of primary molars and a control group of 48 patients with intact temporary teeth. It was evaluated the angle between longitudinal axis of first and second upper permanent molars and occlusal plane. The sofware used is Easy Dent 4 Viewer®.The data were analyzed by using the Statistical Package for the Social Sciences (version 20.0; SPSS, Chicago, III). It was observed that premature loss of upper second deciduous molars modifies greater the vertical axis of the permanent molars than the premature loss of first upper primary molar. First upper primary molar loss cause an acceleration eruption of first premolar, which will produce a distal inclintion of the both permanent molars. The use of space maintainers after premature loss of the second upper temporary molar is a last solution in preventing tridimensional lesions in the dental arch and occlusion.

  2. Influence of hydrostatic pressure on dynamics and spatial distribution of protein partial molar volume: time-resolved surficial Kirkwood-Buff approach.

    Science.gov (United States)

    Yu, Isseki; Tasaki, Tomohiro; Nakada, Kyoko; Nagaoka, Masataka

    2010-09-30

    The influence of hydrostatic pressure on the partial molar volume (PMV) of the protein apomyoglobin (AMb) was investigated by all-atom molecular dynamics (MD) simulations. Using the time-resolved Kirkwood-Buff (KB) approach, the dynamic behavior of the PMV was identified. The simulated time average value of the PMV and its reduction by 3000 bar pressurization correlated with experimental data. In addition, with the aid of the surficial KB integral method, we obtained the spatial distributions of the components of PMV to elucidate the detailed mechanism of the PMV reduction. New R-dependent PMV profiles identified the regions that increase or decrease the PMV under the high pressure condition. The results indicate that besides the hydration in the vicinity of the protein surface, the outer space of the first hydration layer also significantly influences the total PMV change. These results provide a direct and detailed picture of pressure induced PMV reduction.

  3. A finite element analysis of the stress distribution to the mandible from impact forces with various orientations of third molars*

    Science.gov (United States)

    Liu, Yun-feng; Wang, Russell; Baur, Dale A.; Jiang, Xian-feng

    2018-01-01

    Objective: To investigate the stress distribution to the mandible, with and without impacted third molars (IM3s) at various orientations, resulting from a 2000-Newton impact force either from the anterior midline or from the body of the mandible. Materials and methods: A 3D mandibular virtual model from a healthy dentate patient was created and the mechanical properties of the mandible were categorized to 9 levels based on the Hounsfield unit measured from computed tomography (CT) images. Von Mises stress distributions to the mandibular angle and condylar areas from static impact forces (Load I-front blow and Load II left blow) were evaluated using finite element analysis (FEA). Six groups with IM3 were included: full horizontal bony, full vertical bony, full 450 mesioangular bony, partial horizontal bony, partial vertical, and partial 450 mesioangular bony impaction, and a baseline group with no third molars. Results: Von Mises stresses in the condyle and angle areas were higher for partially than for fully impacted third molars under both loading conditions, with partial horizontal IM3 showing the highest fracture risk. Stresses were higher on the contralateral than on the ipsilateral side. Under Load II, the angle area had the highest stress for various orientations of IM3s. The condylar region had the highest stress when IM3s were absent. Conclusions: High-impact forces are more likely to cause condylar rather than angular fracture when IM3s are missing. The risk of mandibular fracture is higher for partially than fully impacted third molars, with the angulation of impaction having little effect on facture risk. PMID:29308606

  4. Mass-action model analysis of the apparent molar volume and heat capacity of pluronics in water and liposome suspensions at 25 °C.

    Science.gov (United States)

    Quirion, François; Meilleur, Luc; Lévesque, Isabelle

    2013-07-09

    Pluronics are block copolymers composed of a central block of polypropylene oxide and two side chains of polyethylene oxide. They are used in water to generate aggregates and gels or added to phospholipid suspensions to prepare microparticles for drug delivery applications. The structure of these systems has been widely investigated. However, little is known about the mechanisms leading to these structures. This investigation compares the apparent molar volumes and heat capacities of Pluronics F38, F108, F127, P85, P104, and P103 at 25 °C in water and in the presence of lecithin liposomes. The changes in molar volumes, heat capacities, and enthalpies generated by a mass-action model are in good agreement with the loss of hydrophobic hydration of the polypropylene oxide central block of the Pluronics. However, the molecularity of the endothermic transitions is much smaller than the aggregation numbers reported in the literature for the same systems. It is suggested that Pluronics go through dehydration of their central block to form unimolecular or small entities having a hydrophobic polypropylene oxide core. In water, these entities would assemble athermally to form larger aggregates. In the presence of liposomes, they would be transferred into the hydrophobic lecithin bilayers of the liposomes. Light transmission experiments suggest that the liposome suspensions are significantly altered only when the added Pluronics are in the dehydrated state.

  5. Effects of partial slip boundary condition and radiation on the heat and mass transfer of MHD-nanofluid flow

    Science.gov (United States)

    Abd Elazem, Nader Y.; Ebaid, Abdelhalim

    2017-12-01

    In this paper, the effect of partial slip boundary condition on the heat and mass transfer of the Cu-water and Ag-water nanofluids over a stretching sheet in the presence of magnetic field and radiation. Such partial slip boundary condition has attracted much attention due to its wide applications in industry and chemical engineering. The flow is basically governing by a system of partial differential equations which are reduced to a system of ordinary differential equations. This system has been exactly solved, where exact analytical expression has been obtained for the fluid velocity in terms of exponential function, while the temperature distribution, and the nanoparticles concentration are expressed in terms of the generalized incomplete gamma function. In addition, explicit formulae are also derived from the rates of heat transfer and mass transfer. The effects of the permanent parameters on the skin friction, heat transfer coefficient, rate of mass transfer, velocity, the temperature profile, and concentration profile have been discussed through tables and graphs.

  6. Determinations of enthalpy and partial molar enthalpy in the alloys Bi–Cd–Ga–In–Zn, Bi–Cd–Ga–Zn and Au–Cu–Sn

    International Nuclear Information System (INIS)

    Arslan, Hüseyin

    2015-01-01

    In the present study, the relations of thermodynamic associated with Chou's general solution model (GSM), the models of Muggianu and Toop have been used in order to calculate the mixing enthalpy and partial molar mixing enthalpy of mixing of Bi–Cd–Ga–In–Zn, Bi–Cd–Ga–Zn with equimolar section at a temperature of 730 K and Au–Cu–Sn with the section x Au /x Cu = 1/1 on the entire molar fraction range as a function of alloy composition at a temperature of 900 K. Some negativities are reported in the selected alloys mentioned above, particularly at high temperatures for the human health as well as difficulties in experimental measurement and high costs. Moreover, aim of us is to close the current article gap seen in the literature. In order to close the current gap seen in the literature, the article on the thermodynamic properties of the Bi–Cd–Ga–In–Zn alloys are presented in this study. - Highlights: • Thermodynamic properties of alloys in the study in given conditions were treated. • The activity of Bi seen in all models shows greatly positive deviation from ideality. • The enthalpy of Sn shows small negative values in x Au /x Cu = 1 at 900 K. • The activity of Sn shows negative deviation from ideality in the same conditions

  7. Study of thermodynamic and acoustic behaviour of nicotinic acid in binary aqueous mixtures of D-lactose

    Science.gov (United States)

    Sharma, Ravi; Thakur, R. C.

    2017-07-01

    In the present study, the thermodynamic properties such as partial molar volumes, partial molar expansibilities, partial molar compressibilities, partial molar heat capacities and isobaric thermal expansion coefficient of different solutions of nicotinic acid in binary aqueous mixtures of D-lactose have been determined at different temperatures (298.15, 303.15, 308.15, 313.15) K. Masson's equation is used to interpret the data in terms of solute-solute and solute-solvent interactions. In the present study it has been found that nicotinic acid behaves as structure maker in aqueous and binary aqueous mixtures of D-lactose.

  8. The Partial Molar Volume and Compressibility of the FeO Component in Model Basalts (Mixed CaAl2Si2O8-CaMgSi2O6-CaFeSi2O6 Liquids) at 0 GPa: evidence of Fe2+ in 6-fold coordination

    Science.gov (United States)

    Guo, X.; Lange, R. A.; Ai, Y.

    2010-12-01

    FeO is an important component in magmatic liquids and yet its partial molar volume at one bar is not as well known as that for Fe2O3 because of the difficulty of performing double-bob density measurements under reducing conditions. Moreover, there is growing evidence from spectroscopic studies that Fe2+ occurs in 4, 5, and 6-fold coordination in silicate melts, and it is expected that the partial molar volume and compressibility of the FeO component will vary accordingly. We have conducted both density and relaxed sound speed measurements on four liquids in the An-Di-Hd (CaAl2Si2O8-CaMgSi2O6-CaFeSi2O6) system: (1) Di-Hd (50:50), (2) An-Hd (50:50), (3) An-Di-Hd (33:33:33) and (4) Hd (100). Densities were measured between 1573 and 1838 K at one bar with the double-bob Archimedean method using molybdenum bobs and crucibles in a reducing gas (1%CO-99%Ar) environment. The sound speeds were measured under similar conditions with a frequency-sweep acoustic interferometer, and used to calculate isothermal compressibility. All the density data for the three multi-component (model basalt) liquids were combined with density data on SiO2-Al2O3-CaO-MgO-K2O-Na2O liquids (Lange, 1997) in a fit to a linear volume equation; the results lead to a partial molar volume (±1σ) for FeO =11.7 ± 0.3(±1σ) cm3/mol at 1723 K. This value is similar to that for crystalline FeO at 298 K (halite structure; 12.06 cm3/mol), which suggests an average Fe2+ coordination of ~6 in these model basalt compositions. In contrast, the fitted partial molar volume of FeO in pure hedenbergite liquid is 14.6 ± 0.3 at 1723 K, which is consistent with an average Fe2+ coordination of 4.3 derived from EXAFS spectroscopy (Rossano, 2000). Similarly, all the compressibility data for the three multi-component liquids were combined with compressibility data on SiO2-Al2O3-CaO-MgO liquids (Ai and Lange, 2008) in a fit to an ideal mixing model for melt compressibility; the results lead to a partial molar

  9. Endodontic management of a mandibular third molar fused with a fourth molar.

    Science.gov (United States)

    Turell, I L; Zmener, O

    1999-05-01

    Developmental anomalies in permanent molars frequently require surgical intervention. A case of a mandibular third molar fused with a fourth molar which was successfully treated with conservative endodontic therapy is reported.

  10. Analysis on the Role of RSG-GAS Pool Cooling System during Partial Loss of Heat Sink Accident

    Science.gov (United States)

    Susyadi; Endiah, P. H.; Sukmanto, D.; Andi, S. E.; Syaiful, B.; Hendro, T.; Geni, R. S.

    2018-02-01

    RSG-GAS is a 30 MW reactor that is mostly used for radioisotope production and experimental activities. Recently, it is regularly operated at half of its capacity for efficiency reason. During an accident, especially loss of heat sink, the role of its pool cooling system is very important to dump decay heat. An analysis using single failure approach and partial modeling of RELAP5 performed by S. Dibyo, 2010 shows that there is no significant increase in the coolant temperature if this system is properly functioned. However lessons learned from the Fukushima accident revealed that an accident can happen due to multiple failures. Considering ageing of the reactor, in this research the role of pool cooling system is to be investigated for a partial loss of heat sink accident which is at the same time the protection system fails to scram the reactor when being operated at 15 MW. The purpose is to clarify the transient characteristics and the final state of the coolant temperature. The method used is by simulating the system in RELAP5 code. Calculation results shows the pool cooling systems reduce coolant temperature for about 1 K as compared without activating them. The result alsoreveals that when the reactor is being operated at half of its rated power, it is still in safe condition for a partial loss of heat sink accident without scram.

  11. Performance simulation of an absorption heat transformer operating with partially miscible mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, D.; Cachot, T.; Hornut, J.M. [LSGC-CNRS-ENSIC, Nancy (France); Univ. Henri Poincare, Nancy (France). IUT

    2002-07-08

    This paper proposes to study the thermodynamics performances of a new absorption heat-transformer cycle, where the separation step is obtained by the cooling and settling of a partially miscible mixture at low temperature. This new cycle has been called an absorption-demixing heat transformer (ADHT) cycle. A numerical simulation code has been written, and has allowed us to evaluate the temperature lift and thermal yield of 2 working pairs. Both high qualitative and quantitative performances have been obtained, so demonstrating the feasibility and industrial interest for such a cycle. Moreover a comparison of the simulation results with performances really obtained on an experimental ADHT has confirmed the pertinence of the simulation code.(author)

  12. [A phd completed 10. Implant-supported removable partial -dentures in a Kennedy Class I-situation in the mandible].

    Science.gov (United States)

    Jensen-Louwerse, C

    2017-06-01

    Implant-supported removable partial dentures in the mandible often cause problems, which means that patients wear their dentures seldom if at all. A solution is to place implants that the dentures can be snapped onto. There is, however, no consensus about the best position of the implants in the mandible yet. In addition, it is worthwhile to balance the cost of treatment with its effectiveness. In a randomised cross-over clinical trial involving 30 patients with a shortened dental arch, the implant-supported removable partial denture in the mandible was evaluated based on the experience of the patient, mean time of wearing, chewing ability and the clinical and radiographic parameters in relation to 2 different implant positions: 2 in the pre-molar region or 2 in the molar region. The cost-effectiveness of both treatments was also evaluated. From the patient's point of view, the implant-supported removable partial dentures are best supported by implants placed in the molar region. The research also revealed, however, that significantly more bleeding occurred around implants placed in the molar region and from a clinical perspective placement in the pre-molar region would have preference. The cost-effectiveness of the treatment with an implant-supported removable partial denture depends on the choice of outcome measurement and monetary threshold.

  13. Thickness and fit of mouthguards according to heating methods.

    Science.gov (United States)

    Mizuhashi, Fumi; Koide, Kaoru; Takahashi, Mutsumi

    2014-02-01

    The purpose of this study was to examine the difference in the thickness and fit of mouthguards made by four different heating methods of the mouthguard sheet material. A Sports Mouthguard(®) of 3.8-mm thickness was used in this study. Four heating methods were performed. In one method, the sheet was heated only one side. In the other methods, one side of the sheet was heated first until the center of the sheet was displaced by 0.5 cm, 1.0 cm, and 1.5 cm from the baseline, and then turned upside down and heated. The sheets were adapted using a vacuum former when the heated sheets hung 1.5 cm from the baseline. We measured the thickness and fit of the mouthguard at the areas of the central incisor and first molar. The difference in thickness at the central incisor and first molar regions was analyzed by two-way anova. The difference in fit with different heating methods was analyzed by one-way anova. The results showed that the thickness of the mouthguard differed in the central incisor and first molar areas (P heating methods. The fit of the mouthguard at the central incisor and first molar areas was significantly different among the heating methods (P heated surface of the sheet contacted the surface of the working model. This finding may help to fabricate accurate mouthguards. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Experimental excess molar properties of binary mixtures of (3-amino-1-propanol + isobutanol, 2-propanol) at T = (293.15 to 333.15) K and modelling the excess molar volume by Prigogine–Flory–Patterson theory

    International Nuclear Information System (INIS)

    Kermanpour, F.; Niakan, H.Z.

    2012-01-01

    Highlights: ► Density and viscosity of binary mixtures of propanol derivatives were measured at T = (293.15 to 333.15) K. ► The excess molar properties were calculated from these experimental data and correlated by Redlich–Kister equation. ► The PFP model was applied for correlating the excess molar volumes. - Abstract: Density and viscosity of binary mixtures of (x 1 3-amino-1-propanol + x 2 isobutanol) and (x 1 3-amino-1-propanol + x 2 2-propanol) were measured over the entire composition range and from temperatures (293.15 to 333.15) K at ambient pressure. The excess molar volumes and viscosity deviations were calculated and correlated by the Redlich–Kister (RK) equation. The thermal expansion coefficient and its excess value, isothermal coefficient of excess molar enthalpy, and excess partial molar volumes were determined by using the experimental values of density and are described as a function of composition and temperature. The excess molar volumes are negative over the entire mole fraction range for both mixtures and increase with increasing temperature. The excess molar volumes obtained were correlated by the Prigogine–Flory–Patterson (PFP) model. The viscosity deviations of the binary mixtures are negative over the entire composition range and decrease with increasing temperature.

  15. Liquid heat capacity of the solvent system (piperazine + n-methyldiethanolamine + water)

    International Nuclear Information System (INIS)

    Chen, Y.-R.; Caparanga, Alvin R.; Soriano, Allan N.; Li, M.-H.

    2010-01-01

    A new set of values for the heat capacity of aqueous mixtures of piperazine (PZ) and n-methyldiethanolamine (MDEA) at different concentrations and temperatures are reported in this paper. The differential scanning calorimetry technique was used to measure the property over the range T = 303.2 K to T = 353.2 K for mixtures containing 0.60 to 0.90 mole fraction water with 15 different concentrations of the system (PZ + MDEA + H 2 O). Heat capacity for four concentrations of the binary system (PZ + MDEA) was also measured. A Redlich-Kister-type equation was adopted to estimate the excess molar heat capacity, which was used to predict the value of the molar heat capacity at a particular concentration and temperature, which would then be compared against the measured value. A total of 165 data points fit into the model resulted in a low overall average absolute deviation of 4.6% and 0.3% for the excess molar heat capacity and molar heat capacity, respectively. Thus, the results presented here are of acceptable accuracy for use in engineering process design.

  16. Relation between heat of vaporization, ion transport, molar volume, and cation-anion binding energy for ionic liquids.

    Science.gov (United States)

    Borodin, Oleg

    2009-09-10

    A number of correlations between heat of vaporization (H(vap)), cation-anion binding energy (E(+/-)), molar volume (V(m)), self-diffusion coefficient (D), and ionic conductivity for 29 ionic liquids have been investigated using molecular dynamics (MD) simulations that employed accurate and validated many-body polarizable force fields. A significant correlation between D and H(vap) has been found, while the best correlation was found for -log(DV(m)) vs H(vap) + 0.28E(+/-). A combination of enthalpy of vaporization and a fraction of the cation-anion binding energy was suggested as a measure of the effective cohesive energy for ionic liquids. A deviation of some ILs from the reported master curve is explained based upon ion packing and proposed diffusion pathways. No general correlations were found between the ion diffusion coefficient and molecular volume or the diffusion coefficient and cation/anion binding energy.

  17. Prediction of nanofluids properties: the density and the heat capacity

    Science.gov (United States)

    Zhelezny, V. P.; Motovoy, I. V.; Ustyuzhanin, E. E.

    2017-11-01

    The results given in this report show that the additives of Al2O3 nanoparticles lead to increase the density and decrease the heat capacity of isopropanol. Based on the experimental data the excess molar volume and the excess molar heat capacity were calculated. The report suggests new method for predicting the molar volume and molar heat capacity of nanofluids. It is established that the values of the excess thermodynamic functions are determined by the properties and the volume of the structurally oriented layers of the base fluid molecules near the surface of nanoparticles. The heat capacity of the structurally oriented layers of the base fluid is less than the heat capacity of the base fluid for given parameters due to the greater regulation of its structure. It is shown that information on the geometric dimensions of the structured layers of the base fluid near nanoparticles can be obtained from data on the nanofluids density and at ambient temperature - by the dynamic light scattering method. For calculations of the nanofluids heat capacity over a wide range of temperatures a new correlation based on the extended scaling is proposed.

  18. Molar volume and adsorption isotherm dependence of capillary forces in nanoasperity contacts.

    Science.gov (United States)

    Asay, David B; Kim, Seong H

    2007-11-20

    The magnitude of the capillary force at any given temperature and adsorbate partial pressure depends primarily on four factors: the surface tension of the adsorbate, its liquid molar volume, its isothermal behavior, and the contact geometry. At large contacting radii, the adsorbate surface tension and the contact geometry are dominating. This is the case of surface force apparatus measurements and atomic force microscopy (AFM) experiments with micrometer-size spheres. However, as the size of contacting asperities decreases to the nanoscale as in AFM experiments with sharp tips, the molar volume and isotherm of the adsorbate become very important to capillary formation as well as capillary adhesion. This effect is experimentally and theoretically explored with simple alcohol molecules (ethanol, 1-butanol, and 1-pentanol) which have comparable surface tensions but differing liquid molar volumes. Adsorption isotherms for these alcohols on silicon oxide are also reported.

  19. Heat capacity measurement of CeNbO4(s)

    International Nuclear Information System (INIS)

    Bhojane, S.M.; Kulkarni, Jayanthi; Kulkarni, S.G.

    2012-01-01

    Molar heat capacity of CeNbO 4 (s) was determined using differential scanning calorimeter in the temperature range of 550 to 900 K. The molar heat capacity values were least squares analysed and the dependence of molar heat capacity with temperature for CeNbO 4 (s) can be given as, J K -1 mol -1 = 94.7320 + 0.0852T-1.6073 x 10 6 T -2 (550≤T(K)≤900) Cerium is commonly used as an inactive analogue to plutonium; also it is an important fission product with moderate yield. Various Nb alloys are used as cladding material in nuclear industry. Hosts of thermodynamic data are needed to understand the various phenomena that occur in a nuclear reactor. In the present study, the molar heat capacity of CeNbO 4 (s) has been determined using high temperature differential scanning calorimeter in temperature range 550 to 900 K. This is one of the important compounds in the ternary system of Ce-Nb-O

  20. Fusion of mandibular third molar with supernumerary fourth molar

    OpenAIRE

    López Carriches, C.; Leco Berrocal, I.; Baca Pérez-Bryan, R.

    2008-01-01

    La fusión dental es la unión de dos gérmenes dentales normalmente separados, mientras que la geminación se define como el intento de división de un único germen dental. La fusión y geminación de molares es poco frecuente en la dentición permanente. Describimos un caso clínico de un tercer molar inferior derecho fusionado a un cuarto molar supernumerario en un paciente varón de 36 años que ha presentado repetidos episodios de pericoronaritis. Tras el estudio radiológico se realiza la exodoncia...

  1. Comparative analysis of unilateral removable partial denture and classical removable partial denture by using finite element method

    Directory of Open Access Journals (Sweden)

    Radović Katarina

    2010-01-01

    Full Text Available Introduction. Various mobile devices are used in the therapy of unilateral free-end saddle. Unilateral dentures with precise connectivity elements are not used frequently. In this paper the problem of applying and functionality of unilateral freeend saddle denture without major connector was taken into consideration. Objective. The aim was to analyze and compare a unilateral RPD (removable partial denture and a classical RPD by calculating and analyzing stresses under different loads. Methods. 3D models of unilateral removable partial denture and classical removable partial denture with casted clasps were made by using computer program CATIA V5 (abutment teeth, canine and first premolar, with crowns and abutment tissues were also made. The models were built in full-scale. Stress analyses for both models were performed by applying a force of 300 N on the second premolar, a force of 500 N on the first molar and a force of 700 N on the second molar. Results. The Fault Model Extractor (FME analysis and calculation showed the complete behavior of unilateral removable partial denture and abutments (canine and first premolar, as well as the behavior of RPD under identical loading conditions. Applied forces with extreme values caused high stress levels on both models and their abutments within physiological limits. Conclusion. Having analyzed stresses under same conditions, we concluded that the unilateral RPD and classical RPD have similar physiological values.

  2. [Correlation between the lower first permanent molar axis and the premature loss of temporary molars].

    Science.gov (United States)

    Petcu, Ana; Maxim, A; Haba, Danisia

    2009-01-01

    The aim of our study was to determine the impact of premature loss of temporary molars upon the longitudinal axis of the first permanent molar. The study sample was formed by 94 orthopanthomografies of child patients with premature loss of lower temporary molars (first or second) after clinical eruption of the first permanent molar. All panoramic radiographs have been realized with the same panoramic unit with 1.4% magnification coefficient and were analyzed using a standardized technique of tracing the images of teeth and bone on matte acetate paper. It was evaluated the angle between longitudinal axis of first permanent lower molar and occlusal plane. It was observed that premature loss of lower second deciduous molar modifies greater the vertical axis of first permanent molar (between 61 degrees and 79 degrees) then premature loss of first lower primary molar. This is perhaps because the loss of space in the case of premature exfoliation of first primary molar is due more to distal drift of canine then mesial drift of molars. The drift to mesial of first permanent molar is more accentuated proportional with the age at which appeared premature loss and so it is loss of leeway space.

  3. Life time test of a partial model of HTGR helium-helium heat exchanger

    International Nuclear Information System (INIS)

    Kitagawa, Masaki; Hattori, Hiroshi; Ohtomo, Akira; Teramae, Tetsuo; Hamanaka, Junichi; Itoh, Mitsuyoshi; Urabe, Shigemi

    1984-01-01

    Authors had proposed a design guide for the HTGR components and applied it to the design and construction of the 1.5 Mwt helium heat exchanger test loop for the nuclear steel making under the financial support of the Japanese Ministry of International Trade and Industry. In order to assure that the design method covers all the conceivable failure mode and has enough safety margin, a series of life time tests of partial model may be needed. For this project, three types of model tests were performed. A life time test of a partial model of the center manifold pipe and eight heat exchanger tubes were described in this report. A damage criterion with a set of material constants and a simplified method for stress-strain analysis for stub tube under three dimensional load were newly developed and used to predict the lives of each tube. The predicted lives were compared with the experimental lives and good agreement was found between the two. The life time test model was evaluated according to the proposed design guide and it was found that the guide has a safety factor of approximately 200 in life for this particular model. (author)

  4. The influence of heat treatments on several types of base-metal removable partial denture alloys.

    Science.gov (United States)

    Morris, H F; Asgar, K; Rowe, A P; Nasjleti, C E

    1979-04-01

    Four removable partial denture alloys, Vitallium (Co-Cr alloy), Dentillium P.D. (Fe-Cr alloy), Durallium L.G. (Co-Cr-Ni alloy), and Ticonium 100 (Ni-Cr alloy), were evaluated in the as-cast condition and after heat treatment for 15 minutes at 1,300 degrees, 1,600 degrees, 1,900 degrees, and 2,200 degrees F followed by quenching in water. The following properties were determined and compared for each alloy at each heat treatment condition: the yield strengths at 0.01%, 0.1%, and 0.2% offsets, the ultimate tensile strength, the percent elongation, the modulus of elasticity, and the Knoop microhardness. The results were statistically analyzed. Photomicrographs were examined for each alloy and test condition. The following conclusions were made: 1. The "highest values" were exhibited by the as-cast alloy. 2. Heat treatment of the partial denture alloys tested resulted in reductions in strength, while the elongations varied. This study demonstrates that, in practice, one should avoid (a) prolonged "heat-soaking" while soldering and (b) grinding or polishing of the casting until the alloy is "red hot". 3. Durallium L.G. was the least affected by the various heat treatment conditions. 4. Conventional reporting of the yield strength at 0.2% offset, the ultimate tensile strength, and percent elongation are not adequate to completely describe and compare the mechanical behavior of alloys. The reporting of the yield strength at 0.01% offset, in addition to the other reported properties, will provide a more complete description of the behavior of the dental alloys.

  5. [Hyperthyroidism in molar pregnancy].

    Science.gov (United States)

    Boufettal, H; Mahdoui, S; Noun, M; Hermas, S; Samouh, N

    2014-03-01

    Hyperthyroidism is a rare complication of molar pregnancy. We report a 39-year-old woman who presented a thyrotoxic syndrome accompanying a molar pregnancy. Serum thyroid hormones were elevated and returned to normal level after uterine evacuation of a molar pregnancy. The authors detail the role of thyroid stimulating property of human gonadotropin chorionic hormone and its structural changes during the gestational trophoblastic diseases. These changes give the latter the thyroid stimulating properties and signs of hyperthyroidism. Molar pregnancy may be a cause of hyperthyroidism. The diagnosis of molar pregnancy should be a mention to thyrotoxicosique syndrome in a woman of childbearing age. Copyright © 2013. Published by Elsevier SAS.

  6. Pathological (late) fractures of the mandibular angle after lower third molar removal: a case series.

    Science.gov (United States)

    Cutilli, Tommaso; Bourelaki, Theodora; Scarsella, Secondo; Fabio, Desiderio Di; Pontecorvi, Emanuele; Cargini, Pasqualino; Junquera, Luis

    2013-04-30

    Pathological (late) fracture of the mandibular angle after third molar surgery is very rare (0.005% of third molar removals). There are 94 cases reported in the literature; cases associated with osseous pathologies such as osteomyelitis or any local and systemic diseases that may compromise mandibular bone strength have not been included. We describe three new cases of pathological (late) fracture of the mandibular angle after third molar surgery. The first patient was a 27-year-old Caucasian man who had undergone surgical removal of a 3.8, mesioangular variety, class II-C third molar 20 days before admission to our clinic. The fracture of his left mandibular angle, complete and composed, occurred during chewing. The second patient was a 32-year-old Caucasian man. He had undergone surgical removal of a 3.8, mesioangular variety, class II-B third molar 22 days before his admission. The fracture, which occurred during mastication, was studied by computed tomography that showed reparative tissue in the fracture site. The third patient was a 36-year-old Caucasian man who had undergone surgical removal of a 3.8, vertical variety, class II-C third molar 25 days before the observation. In this case the fracture of his mandibular angle was oblique (unfavorable), complete and composed. The fracture had occurred during chewing. We studied the fracture by optical projection tomography and computed tomography.All of the surgical removals of the 3.8 third molars, performed by the patients' dentists who had more than 10 years of experience, were difficult. We treated the fractures with open surgical reduction, internal fixation by titanium miniplates and intermaxillary elastic fixation removed after 6 weeks. The literature indicates that the risk of pathological (late) fracture of the mandibular angle after third molar surgery for total inclusions (class II-III, type C) is twice that of partial inclusions due to the necessity of ostectomies more generous than those for partial

  7. Mobility of partially molten crust, heat and mass transfer, and the stabilization of continents

    Science.gov (United States)

    Teyssier, Christian; Whitney, Donna L.; Rey, Patrice F.

    2017-04-01

    The core of orogens typically consists of migmatite terrains and associated crustal-derived granite bodies (typically leucogranite) that represent former partially molten crust. Metamorphic investigations indicate that migmatites crystallize at low pressure (cordierite stability) but also contain inclusions of refractory material (mafic, aluminous) that preserve evidence of crystallization at high pressure (HP), including HP granulite and eclogite (1.0-1.5 GPa), and in some cases ultrahigh pressure (2.5-3.0 GPa) when the continental crust was subducted (i.e. Norwegian Caledonides). These observations indicate that the partially molten crust originates in the deep crust or at mantle depths, traverses the entire orogenic crust, and crystallizes at shallow depth, in some cases at the near-surface ( 2 km depth) based on low-T thermochronology. Metamorphic assemblages generally show that this nearly isothermal decompression is rapid based on disequilibrium textures (symplectites). Therefore, the mobility of partially molten crust results in one of the most significant heat and mass transfer mechanisms in orogens. Field relations also indicate that emplacement of partially molten crust is the youngest major event in orogeny, and tectonic activity essentially ceases after the partially molten crust is exhumed. This suggests that flow and emplacement of partially molten crust stabilize the orogenic crust and signal the end of orogeny. Numerical modeling (open source software Underworld; Moresi et al., 2007, PEPI 163) provides useful insight into the mechanisms of exhumation of partially molten crust. For example, extension of thickened crust with T-dependent viscosity shows that extension of the shallow crust initially drives the mobility of the lowest viscosity crust (T>700°C), which begins to flow in a channel toward the zone of extension. This convergent flow generates channel collision and the formation of a double-dome of foliation (two subdomes separated by a steep

  8. SECOND MOLAR UPRIGHTING AFTER PREMATURE LOSS OF MANDIBULAR FIRST PERMANENT MOLAR--CASE REPORT.

    Science.gov (United States)

    Cernei, E R; Mavru, R B; Zetui, Irina Nicoleta

    2015-01-01

    Uprighting a tipped molar by using an uprighting spring is a fundamental orthodontic treatment technique. Following a weak anchorage done only by the anterior teeth the permanent lower second molar will rotate around its center of resistance, and besides the distalizing movement will occur its extrusion. Following the reaction, the mandibular anterior teeth will have a movement of intrusion. All these elements will lead to anterior open bite. Correction of vertical problems has become easier with the advent of mini-implants. U.I patient aged 24 years presenting for aesthetic and functional disorders. Clinical examination reveals intraoral Class I molar malocclusion on the right sight, upper narrowing arch with a slight overbite, and the both permanent first molars on the left side lost prematurely. The tooth 37 is inclined at 600 degrees to the plane of occlusion. To avoid front opening occlusion we used an orthodontic miniscrew inserted between the canine and the first premolar on the same side to achieve the second molar up righting. Lower second molar uprighting was achieved without unwanted movements in anterior mandibular region and without molar extrusion. Using mini implants in uprighting a tipped molar will achieve the desired tooth movement and will reduce the number of unwanted side effects and eventually to improve patient's esthetics.

  9. Densities, excess molar volumes, speeds of sound and isothermal compressibilities for {2-(2-hexyloxyethoxy)ethanol + n-alkanol} systems at temperatures between (288.15 and 308.15) K

    International Nuclear Information System (INIS)

    Pal, Amalendu; Gaba, Rekha

    2008-01-01

    The densities, ρ and the speeds of sound, u, for {2-(2-hexyloxyethoxy)ethanol (C 6 E 2 ) + methanol, +1-propanol, +1-pentanol, and +1-heptanol} have been measured as a function of composition using an Anton-Paar DSA 5000 densimeter at temperatures (288.15, 293.15, 298.15, 303.15, and 308.15) K and atmospheric pressure over the whole concentration range. The ρ and u values were used to calculate excess molar volumes, V E , and excess molar isentropic compressibility, K S,m E , respectively. Also, thermal expansivity, α, partial molar volume, V-bar i , and partial molar volume of the components at infinite dilution, V-bar i 0 , have been calculated. The variation of these properties with composition and temperature of the mixtures are discussed in terms of molecular interactions

  10. Enhanced heat transfer in partially open square cavities with thin fin by using electric field

    International Nuclear Information System (INIS)

    Kasayapanand, N.; Kiatsiriroat, T.

    2009-01-01

    Numerical modeling of the electric field effect on the natural convection in the partially open square cavities with thin fin attached is investigated. The interactions among electric, flow, and temperature fields are analyzed by using a computational fluid dynamics technique. It is found that the flow and heat transfer enhancements are a decreasing function of the Rayleigh number. Moreover, the volume flow rate and heat transfer coefficient are substantially improved by electrohydrodynamic especially at low aperture size, high aperture position, and high inclined angle. Surprisingly, the maximum convective heat transfer is obtained at the minimum electrical energy consumption by placing electrodes at a suitable position. The optimum electrode arrangements for both single fin and multiple fins are also achieved

  11. Excess Molar Volume, Viscosity and Heat Capacity for the Binary Mixture of p-Xylene and Acetic Acid at Different Temperatures%对二甲苯和醋酸二元液体混合物在不同温度下的超额摩尔体积、粘度和热容

    Institute of Scientific and Technical Information of China (English)

    杨长生; 马沛生; 唐多强; 尹秋响; 赵长伟

    2002-01-01

    Experimental densities, viscosities and heat capacities at different temperatures were presented overthe entire range of mole fraction for the binary mixture of p-xylene and acetic acid. Density values were used in thedetermination of excess molar volumes, VE. At the same time, the excess viscosity and excess molar heat capacitieswere calculated. The values of VE, ηE and cpE were fitted to the Redlich-Kister equation. Good agreements wereobserved. The excess molar volumes are positive with a large maximum value located in the central concentrationrange. The excess viscosity has an opposite trend to the excess molar volume VE. ηE values are negative over theentire range of the mixture. The cure of dependence of cEp on concentration has a special shape. The molecularinteraction between p-xylene and acetic acid is discussed.

  12. Determination of thermodynamic properties of poly(cyclohexyl methacrylate)by inverse gas chromatography

    Institute of Scientific and Technical Information of China (English)

    Ismet KAYA; Cigdem Yigit PALA

    2014-01-01

    In this work,some thermodynamic properties of poly( cyclohexyl methacrylate)were studied by inverse gas chromatography( IGC). For this purpose,the polymeric substance was coated on Chromosorb W and which was filled into a glass column. The retention times(tr)of the probes were determined from the interactions of poly(cyclohexyl methacrylate)with n-pentane,n-hexane,n-heptane,n-octane,n-decane, methanol,ethanol,2-propanol,butanol,acetone,ethyl methyl ketone,benzene,toluene and o-xylene by IGC technique. Then,the specific volume(V0g)was determined for each probe molecule. By using(1/T;lnV0g) graphics,the glass transition temperature of poly( cyclohexyl methacrylate)was found to be 373 K. The adsorp-tion heat under the glass transition temperature(ΔH a ),and partial molar heat of sorption above the glass tran-sition(ΔHS1 ),partial molar free energy of sorption(ΔGS1 )and partial molar entropy of sorption(ΔSS1 )belong-ing to sorption for every probe were calculated. The partial molar heat of mixing at infinite dilution(ΔH∞1 ), partial molar free energy of mixing at infinite dilution(ΔG∞1 ),Flory-Huggins interaction parameter(χ∞12 )and weight fraction activity coefficient(a1/w1)∞ values of polymer-solute systems were calculated at different col-umn temperatures. The solubility parameters(δ2 )of the polymer were obtained by IGC technique.

  13. Determination of thermodynamic properties of poly (cyclohexyl methacrylate) by inverse gas chromatography.

    Science.gov (United States)

    Kaya, Ismet; Pala, Cigdem Yigit

    2014-07-01

    In this work, some thermodynamic properties of poly (cyclohexyl methacrylate) were studied by inverse gas chromatography (IGC). For this purpose, the polymeric substance was coated on Chromosorb W and which was filled into a glass column. The retention times (t(r)) of the probes were determined from the interactions of poly (cyclohexyl methacrylate) with n-pentane, n-hexane, n-heptane, n-octane, n-decane, methanol, ethanol, 2-propanol, butanol, acetone, ethyl methyl ketone, benzene, toluene and o-xylene by IGC technique. Then, the specific volume (Vg(0)) was determined for each probe molecule. By using (1/T; lnVg(0)) graphics, the glass transition temperature of poly (cyclohexyl methacrylate) was found to be 373 K. The adsorption heat under the glass transition temperature (deltaH(a)), and partial molar heat of sorption above the glass transition (deltaH1(S)), partial molar free energy of sorption (deltaG1(S)) and partial molar entropy of sorption (deltaS1(S)) belonging to sorption for every probe were calculated. The partial molar heat of mixing at infinite dilution (deltaH1(infinity)), partial molar free energy of mixing at infinite dilution (deltaG1(infinity)), Flory-Huggins interaction parameter (chi12(infinity)) and weight fraction activity coefficient (a1/w1)(infinity) values of polymer-solute systems were calculated at different column temperatures. The solubility parameters (delta2) of the polymer were obtained by IGC technique.

  14. Removable molar power arm

    Directory of Open Access Journals (Sweden)

    Raj Kumar Verma

    2013-01-01

    Full Text Available Attachment of force elements from the gingival hook of maxillary molar tubes during the retraction of the anterior teeth is very common in orthodontic practice. As the line of force passes below the center of resistance (CR of molar, it results its mesial tipping and also anchorage loss. To overcome this problem, the line of force should pass along the CR of molar. This article highlights a method to overcome this problem by attaching a removable power arm to the headgear tube of molar tube during the retraction of the anterior teeth.

  15. Application of Prigogine-Flory-Patterson theory to excess molar volume of mixtures of 1-butyl-3-methylimidazolium ionic liquids with N-methyl-2-pyrrolidinone

    International Nuclear Information System (INIS)

    Qi Feng; Wang Haijun

    2009-01-01

    The densities of two binary mixtures formed by 1-butyl-3-methylimidazolium tetrafluoroborate [bmim][BF 4 ] and 1-butyl-3-methy limidazolium hexafluorophosphate [bmim][PF 6 ] with compound N-methyl-2-pyrrolidinone have been determined over the full range of composition and range of temperature from (298.15 to 313.15) K and at atmospheric pressure using a vibrating-tube densimeter (DMA4500). Excess molar volumes, V m E , have been obtained from these experimental results, and been fitted by the fourth-order Redlich-Kister equation. From the experimental results, partial molar volumes, apparent molar volume and partial molar volumes at infinite dilution were calculated over the whole composition range. Our results show that V m E decreases slightly when temperature increases in the systems studied. The experimental results have been used to test the applicability of the Prigogine-Flory-Patterson (PFP) theory. The results have been interpreted in terms of ion-dipole interactions and structural factors of the ionic liquid and these organic molecular liquids

  16. Spectrum of excess partial molar absorptivity. Part II: a near infrared spectroscopic study of aqueous Na-halides.

    Science.gov (United States)

    Sebe, Fumie; Nishikawa, Keiko; Koga, Yoshikata

    2012-04-07

    Our earlier thermodynamic studies suggested that F(-) and Cl(-) form hydration shells with the hydration number 14 ± 2 and 2.3 ± 0.6, respectively, and leave the bulk H(2)O away from hydration shells unperturbed. Br(-) and I(-), on the other hand, form hydrogen bonds directly with the momentarily existing hydrogen bond network of H(2)O, and retard the degree of entropy-volume cross fluctuation inherent in liquid H(2)O. The effect of the latter is stronger for I(-) than Br(-). Here we seek additional information about this qualitative difference between Cl(-) and (Br(-) and I(-)) pair by near infrared (NIR) spectroscopy. We analyze the ν(2) + ν(3) band of H(2)O in the range 4600-5500 cm(-1) of aqueous solutions of NaCl, NaBr and NaI, by a new approach. From observed absorbance, we calculate excess molar absorptivity, ε(E), excess over the additive contributions of solute and solvent. ε(E) thus contains information about the effect of inter-molecular interactions in the ν(2) + ν(3) spectrum. The spectrum of ε(E) shows three bands; two negative ones at 5263 and 4873 cm(-1), and the positive band at 5123 cm(-1). We then define and calculate the excess partial molar absorptivity of each salt, ε(E)(salt). From the behaviour of ε(E)(salt) we suggest that the negative band at 5263 cm(-1) represents free H(2)O without much hydrogen bonding under the influence of local electric field of ions. Furthermore, from a sudden change in the x(salt) (mole fraction of salt) dependence of ε(E)(salt), we suggest that there is an ion-pairing in x(salt) > 0.032, 0.036, and 0.04 for NaCl, NaBr and NaI respectively. The positive band of ε(E) at 5123 cm(-1) is attributed to a modestly organized hydrogen bond network of H(2)O (or liquid-likeness), and the x(salt) dependence of ε indicated a qualitative difference in the effect of Cl(-) from those of Br(-) and I(-). Namely, the values of ε(E)(salt) stay constant for Cl(-) but those for Br(-) and I(-) decrease smoothly on

  17. Isentropic expansion and related thermodynamic properties of non-ionic amphiphile-water mixtures.

    Science.gov (United States)

    Reis, João Carlos R; Douhéret, Gérard; Davis, Michael I; Fjellanger, Inger Johanne; Høiland, Harald

    2008-01-28

    A concise thermodynamic formalism is developed for the molar isentropic thermal expansion, ES,m = ( partial differential Vm/ partial differential T)(Sm,x), and the ideal and excess quantities for the molar, apparent molar and partial molar isentropic expansions of binary liquid mixtures. Ultrasound speeds were determined by means of the pulse-echo-overlap method in aqueous mixtures of 2-methylpropan-2-ol at 298.15 K over the entire composition range. These data complement selected extensive literature data on density, isobaric heat capacity and ultrasound speed for 9 amphiphile (methanol, ethanol, propan-1-ol, propan-2-ol, 2-methylpropan-2-ol, ethane-1,2-diol, 2-methoxyethanol, 2-ethoxyethanol or 2-butoxyethanol)-water binary systems, which form the basis of tables listing molar and excess molar isobaric expansions and heat capacities, and molar and excess molar isentropic compressions and expansions at 298.15 K and at 65 fixed mole fractions spanning the entire composition range and fine-grained in the water-rich region. The dependence on composition of these 9 systems is graphically depicted for the excess molar isobaric and isentropic expansions and for the excess partial molar isobaric and isentropic expansions of the amphiphile. The analysis shows that isentropic thermal expansion properties give a much stronger response to amphiphile-water molecular interactions than do their isobaric counterparts. Depending on the pair property-system, the maximum excess molar isentropic value is generally twenty- to a hundred-fold greater than the corresponding maximum isobaric value, and occurs at a lower mole fraction of the amphiphile. Values at infinite dilution of the 9 amphiphiles in water are given for the excess partial molar isobaric heat capacity, isentropic compression, isobaric expansion and isentropic expansion. These values are interpreted in terms of the changes occurring when amphiphile molecules cluster into an oligomeric form. Present results are discussed

  18. Maxillary second molar impaction in the adjacent ectopic third molar: Report of five rare cases

    Science.gov (United States)

    Souki, Bernardo Q.; Cheib, Paula L.; de Brito, Gabriela M.; Pinto, Larissa S. M. C.

    2015-01-01

    Maxillary second molar impaction in the adjacent ectopic third molar is a rare condition that practitioners might face in the field of pediatric dentistry and orthodontics. The early diagnosis and extraction of the adjacent ectopic third molar have been advocated, and prior research has reported a high rate of spontaneous eruption following third molar removal. However, some challenges in the daily practice are that the early diagnosis of this type of tooth impaction is difficult with conventional radiographic examination, and sometimes the early surgical removal of the maxillary third molar must be postponed because of the risks of damaging the second molar. The objective of this study is to report a case series of five young patients with maxillary second molar impaction and to discuss the difficulty of early diagnosis with the conventional radiographic examination, and unpredictability of self-correction. PMID:26321848

  19. Maxillary second molar impaction in the adjacent ectopic third molar: Report of five rare cases

    Directory of Open Access Journals (Sweden)

    Bernardo Q Souki

    2015-01-01

    Full Text Available Maxillary second molar impaction in the adjacent ectopic third molar is a rare condition that practitioners might face in the field of pediatric dentistry and orthodontics. The early diagnosis and extraction of the adjacent ectopic third molar have been advocated, and prior research has reported a high rate of spontaneous eruption following third molar removal. However, some challenges in the daily practice are that the early diagnosis of this type of tooth impaction is difficult with conventional radiographic examination, and sometimes the early surgical removal of the maxillary third molar must be postponed because of the risks of damaging the second molar. The objective of this study is to report a case series of five young patients with maxillary second molar impaction and to discuss the difficulty of early diagnosis with the conventional radiographic examination, and unpredictability of self-correction.

  20. The premature loss of primary first molars: space loss to molar occlusal relationships and facial patterns.

    Science.gov (United States)

    Alexander, Stanley A; Askari, Marjan; Lewis, Patricia

    2015-03-01

    To investigate space changes with the premature loss of primary first molars and their relationship to permanent molar occlusion and facial forms. Two hundred twenty-six participants (ranging in age from 7 years 8 months to 8 years 2 months; 135 female, 91 male) met all inclusion criteria designed to study space loss as a result of the premature loss of the primary first molar. After 9 months, space loss was evaluated in relationship to molar occlusion and facial form. Statistical evaluation was performed with the paired t-test and with a two-way analysis of variance for independent groups. Patients with leptoprosopic facial form and end-on molar occlusions all exhibited a statistically significant difference when compared to controls in terms of space loss (P molar occlusion displayed space loss as well (P molar occlusion displayed space loss in the maxilla (P molar occlusions showed no significant difference in space loss. The relationship between the first permanent molar occlusion and facial form of the child has an influence on the loss of space at the primary first molar site.

  1. An innovative technique to distalize maxillary molar using microimplant supported rapid molar distalizer

    Directory of Open Access Journals (Sweden)

    Meenu Goel

    2013-01-01

    Full Text Available Introduction: In recent years, enhancements in implants have made their use possible as a mode of absolute anchorage in orthodontic patients. In this paper, the authors have introduced an innovative technique to unilaterally distalize the upper left 1 st molar to obtain an ideal Class I molar relationship from a Class II existing molar relationship with an indigenous designed distalizer. Clinical Innovation: For effective unilateral diatalization of molar, a novel cantilever sliding jig assembly was utilized with coil spring supported by a buccally placed single micro implant. The results showed 3 mm of bodily distalization with 1 mm of intrusion and 2° of distal tipping of upper left 1 st molar in 1.5 months. Discussion: This appliance is relatively easy to insert, well-tolerated, and requires minimal patient cooperation compared to other present techniques of molar distalization. Moreover, it is particularly useful in cases that are Class II on one side and Class I on the other, with a minor midline discrepancy and nominal overjet. Patient acceptance level was reported to be within patients physiological and comfort limits.

  2. Are Hypomineralized Primary Molars and Canines Associated with Molar-Incisor Hypomineralization?

    Science.gov (United States)

    da Silva Figueiredo Sé, Maria Jose; Ribeiro, Ana Paula Dias; Dos Santos-Pinto, Lourdes Aparecida Martins; de Cassia Loiola Cordeiro, Rita; Cabral, Renata Nunes; Leal, Soraya Coelho

    2017-11-01

    The purpose of this study was to evaluate the prevalence of and relationship between hypomineralized second primary molars (HSPM) and hypomineralized primary canines (HPC) with molar-incisor hypomineralization (MIH) in 1,963 schoolchildren. The European Academy of Paediatric Dentistry (EAPD) criterion was used for scoring HSPM/HPC and MIH. Only children with four permanent first molars and eight incisors were considered in calculating MIH prevalence (n equals 858); for HSPM/HPC prevalence, only children with four primary second molars (n equals 1,590) and four primary canines (n equals 1,442) were considered. To evaluate the relationship between MIH/HSPM, only children meeting both criteria cited were considered (n equals 534), as was true of MIH/HPC (n equals 408) and HSPM/HPC (n equals 360; chi-square test and logistic regression). The prevalence of MIH was 14.69 percent (126 of 858 children). For HSPM and HPC, the prevalence was 6.48 percent (103 of 1,592) and 2.22 percent (32 of 1,442), respectively. A significant relationship was observed between MIH and both HSPM/HPC (PMIH based on HSPM was 6.31 (95 percent confidence interval [CI] equals 2.59 to 15.13) and for HPC was 6.02 (95 percent CI equals 1.08 to 33.05). The results led to the conclusion that both hypomineralized second primary molars and hypomineralized primary canines are associated with molar-incisor hypomineralization, because children with HSPM/HPC are six times more likely to develop MIH.

  3. Mini implant supported molar tubes: A novel method for attaching the molar tubes

    Directory of Open Access Journals (Sweden)

    Nitin V Muralidhar

    2017-01-01

    Full Text Available Banding or bonding procedures have been the only means of attaching molar tubes onto the permanent molar teeth till date in the field of orthodontics. This clinical innovation aims to include the use of mini implant for the purpose of attaching the molar tubes thereby eliminating the iatrogenic effects of banding and bonding of the teeth.

  4. Molar Incisor Hypomineralization, Prevalence, and Etiology

    Directory of Open Access Journals (Sweden)

    Sulaiman Mohammed Allazzam

    2014-01-01

    Full Text Available Aim. To evaluate the prevalence and possible etiological factors associated with molar incisor hypomineralization (MIH among a group of children in Jeddah, Saudi Arabia. Methods. A group of 8-12-year-old children were recruited (n=267  from the Pediatric Dental Clinics at the Faculty of Dentistry, King Abdulaziz University. Children had at least one first permanent molar (FPM, erupted or partially erupted. Demographic information, children’s medical history, and pregnancy-related data were obtained. The crowns of the FPM and permanent incisors were examined for demarcated opacities, posteruptive breakdown (PEB, atypical restorations, and extracted FPMs. Children were considered to have MIH if one or more FPM with or without involvement of incisors met the diagnostic criteria. Results. MIH showed a prevalence of 8.6%. Demarcated opacities were the most common form. Maxillary central incisors were more affected than mandibular (P=0.01. The condition was more prevalent in children with history of illnesses during the first four years of life including tonsillitis (P=0.001, adenoiditis (P=0.001, asthma (P=0.001, fever (P=0.014, and antibiotics intake (P=0.001. Conclusions. The prevalence of MIH is significantly associated with childhood illnesses during the first four years of life including asthma, adenoid infections, tonsillitis, fever, and antibiotics intake.

  5. Numerical heat transfer analysis of transcritical hydrocarbon fuel flow in a tube partially filled with porous media

    Directory of Open Access Journals (Sweden)

    Jiang Yuguang

    2016-01-01

    Full Text Available Hydrocarbon fuel has been widely used in air-breathing scramjets and liquid rocket engines as coolant and propellant. However, possible heat transfer deterioration and threats from local high heat flux area in scramjet make heat transfer enhancement essential. In this work, 2-D steady numerical simulation was carried out to study different schemes of heat transfer enhancement based on a partially filled porous media in a tube. Both boundary and central layouts were analyzed and effects of gradient porous media were also compared. The results show that heat transfer in the transcritical area is enhanced at least 3 times with the current configuration compared to the clear tube. Besides, the proper use of gradient porous media also enhances the heat transfer compared to homogenous porous media, which could help to avoid possible over-temperature in the thermal protection.

  6. Theory of chromatography of partially cyclic polymers: Tadpole-type and manacle-type macromolecules.

    Science.gov (United States)

    Vakhrushev, Andrey V; Gorbunov, Alexei A

    2016-02-12

    A theory of chromatography is developed for partially cyclic polymers of tadpole- and manacle-shaped topological structures. We present exact equations for the distribution coefficient K at different adsorption interactions; simpler approximate formulae are also derived, relevant to the conditions of size-exclusion, adsorption, and critical chromatography. Theoretical chromatograms of heterogeneous partially cyclic polymers are simulated, and conditions for good separation by topology are predicted. According to the theory, an effective SEC-radius of tadpoles and manacles is mostly determined by the molar mass M, and by the linear-cyclic composition. In the interactive chromatography, the effect of molecular topology on the retention becomes significant. At the critical interaction point, partial dependences K(Mlin) and K(Mring) are qualitatively different: while being almost independent of Mlin, K increases with Mring. This behavior could be realized in critical chromatography-for separation of partially cyclic polymers by the number and molar mass of cyclic elements. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. What is the fundamental ion-specific series for anions and cations? Ion specificity in standard partial molar volumes of electrolytes and electrostriction in water and non-aqueous solvents.

    Science.gov (United States)

    Mazzini, Virginia; Craig, Vincent S J

    2017-10-01

    The importance of electrolyte solutions cannot be overstated. Beyond the ionic strength of electrolyte solutions the specific nature of the ions present is vital in controlling a host of properties. Therefore ion specificity is fundamentally important in physical chemistry, engineering and biology. The observation that the strengths of the effect of ions often follows well established series suggests that a single predictive and quantitative description of specific-ion effects covering a wide range of systems is possible. Such a theory would revolutionise applications of physical chemistry from polymer precipitation to drug design. Current approaches to understanding specific-ion effects involve consideration of the ions themselves, the solvent and relevant interfaces and the interactions between them. Here we investigate the specific-ion effects trends of standard partial molar volumes and electrostrictive volumes of electrolytes in water and eleven non-aqueous solvents. We choose these measures as they relate to bulk properties at infinite dilution, therefore they are the simplest electrolyte systems. This is done to test the hypothesis that the ions alone exhibit a specific-ion effect series that is independent of the solvent and unrelated to surface properties. The specific-ion effects trends of standard partial molar volumes and normalised electrostrictive volumes examined in this work show a fundamental ion-specific series that is reproduced across the solvents, which is the Hofmeister series for anions and the reverse lyotropic series for cations, supporting the hypothesis. This outcome is important in demonstrating that ion specificity is observed at infinite dilution and demonstrates that the complexity observed in the manifestation of specific-ion effects in a very wide range of systems is due to perturbations of solvent, surfaces and concentration on the underlying fundamental series. This knowledge will guide a general understanding of specific

  8. Molecular theory of partial molar volume and its applications to biomolecular systems

    Directory of Open Access Journals (Sweden)

    T.Imai

    2007-09-01

    Full Text Available The paial molar volume (PMV is a thermodynamic quantity which contains important information about the solute-solvent interactions as well as the solute structure in solution.Additionally, the PMV is the most essential quantity in the analysis of the pressure effect on chemical reactions. This aicle reviews the recent developments in molecular theories of the PMV, especially the reference interaction site model (RISMtheory of molecular liquids and its three-dimensional generalization version (3D-RISM, which are combined with the Kirkwood-Buff solution theory to calculate the PMV. This aicle also introduces our recent applications of the theory to some interesting issues concerning the PMV of biomolecules. In addition, theoretical representations of the effects of intramolecular fluctuation on the PMV, which are significant for biomacromolecules, are briefly discussed.

  9. Oxygen from Hydrogen Peroxide. A Safe Molar Volume-Molar Mass Experiment.

    Science.gov (United States)

    Bedenbaugh, John H.; And Others

    1988-01-01

    Describes a molar volume-molar mass experiment for use in general chemistry laboratories. Gives background technical information, procedures for the titration of aqueous hydrogen peroxide with standard potassium permanganate and catalytic decomposition of hydrogen peroxide to produce oxygen, and a discussion of the results obtained in three…

  10. Extrações de molares na Ortodontia Molar extractions in orthodontics

    Directory of Open Access Journals (Sweden)

    Marco Antônio Schroeder

    2011-12-01

    Full Text Available O tratamento ortodôntico com extração de molares em pacientes adultos é tecnicamente mais complexo, devido a inúmeros fatores. Em geral, o espaço a ser fechado é maior do que o espaço dos pré-molares e, por isso, a ancoragem é crítica e o tempo de tratamento mais longo. É comum esses casos apresentarem algum grau de comprometimento periodontal por causa da idade dos pacientes e, portanto, necessitam de maior controle da mecânica ortodôntica para reduzir os efeitos colaterais do fechamento do espaço. Por isso, bons resultados de finalização são mais difíceis de ser alcançados. Sendo assim, este artigo tem como objetivo apresentar as razões para a indicação de extração de molares nos tratamentos ortodônticos, as contraindicações, as diferentes fases da mecânica ortodôntica, esclarecer os fatores envolvidos nesse tipo de planejamento e tratamento e apresentar casos clínicos tratados com extração de molares.Orthodontic treatment with extraction of molars in adult patients is technically more complex due to a number of factors. In general, the space to be closed is greater than premolar spaces rendering critical anchorage and longer treatment time. Often such cases exhibit some degree of periodontal involvement due to patient age. Hence, the need for greater control over orthodontic mechanics to reduce the side effects of space closure. Therefore, good finishing results can be more difficult to achieve. Thus, the purpose of this article is to determine the reasons for molar extraction indications, describe different stages of orthodontic mechanics, and explain the issues involved in this kind of planning and treatment. Additionally, it aims at describing some treatments with molar extractions.

  11. Molar volume of eutectic solvents as a function of molar composition and temperature☆

    Institute of Scientific and Technical Information of China (English)

    Farouq S. Mjalli

    2016-01-01

    The conventional Rackett model for predicting liquid molar volume has been modified to cater for the effect of molar composition of the Deep Eutectic Solvents (DES). The experimental molar volume data for a group of commonly used DES has been used for optimizing the improved model. The data involved different molar compositions of each DES. The validation of the new model was performed on another set of DESs. The average relative deviation of the model on the training and validation datasets was approximately 0.1%while the Rackett model gave a relative deviation of more than 1.6%. The modified model deals with variations in DES molar com-position and temperature in a more consistent way than the original Rackett model which exhibits monotonic performance degradation as temperature moves away from reference conditions. Having the composition of the DES as a model variable enhances the practical utilization of the predicting model in diverse design and process simulation applications.

  12. Differential Expression of p63 in Hydropic and Molar Gestations

    International Nuclear Information System (INIS)

    Masood, S.; Kehar, S. I.; Shawana, S.; Aamir, I.

    2015-01-01

    Objective:To observe the differential expression of p63 in hydropic and molar gestation. Study Design: Cross-sectional analytical study. Place and Duration of Study: Department of Pathology, Basic Medical Sciences Institute, Jinnah Postgraduate and Medical Centre, Karachi, from January 2006 to June 2013. Methodology: Ninety placental biopsies including 30 cases each of hydropic abortions, partial hydatidiform mole and complete hydatidiform mole were analyzed for morphological features and results of immunohistochemical staining. Results were described as frequency. Significance was determined using test of proportions with significance at p < 0.05. Results: Out of 30 cases of hydropic abortion, 6 were negative, 15 were weak, 4 were moderate and 5 showed strong degree of intensity for p63. Out of 30 cases of partial hydatidiform mole, 3 were negative, 2 showed weak, 4 showed moderate and 21 cases showed strong degree of intensity for p63. All 30 cases of complete hydatidiform mole strongly stained for p63. Conclusion: The intensity of staining of p63 was stronger in cases of molar pregnancy as compared to hydropic abortion. There was loss of p63 expression in cytotrophoblastic cells in all abortions. In limited resources settings, where facilities for PCR/FISH and DNA ploidy analysis is not available, the authors advocate p63 in routine clinical practice to provide the most refined diagnosis of hydatidiform moles. (author)

  13. Application of the PFV EoS correlation to excess molar volumes of (1-ethyl-3-methylimidazolium ethylsulfate + alkanols) at different temperatures

    International Nuclear Information System (INIS)

    Deenadayalu, N.; Sen, S.; Sibiya, P.N.

    2009-01-01

    The experimental densities for the binary systems of an ionic liquid and an alkanol {1-ethyl-3-methylimidazolium ethylsulfate [EMIM] + [EtSO 4 ] - + methanol or 1-propanol or 2-propanol} were determined at T = (298.15, 303.15, and 313.15) K. The excess molar volumes for the above systems were then calculated from the experimental density values for each temperature. The Redlich-Kister smoothing polynomial was used to fit the experimental results and the partial molar volumes were determined from the Redlich-Kister coefficients. For all the systems studied, the excess molar volume results were negative over the entire composition range for all the temperatures. The excess molar volumes were correlated with the pentic four parameter virial (PFV) equation of state (EoS) model

  14. Part 2: Limiting apparent molar volume of organic and inorganic 1:1 electrolytes in (water + ethylammonium nitrate) mixtures at 298 K - Thermodynamic approach using Bahe-Varela pseudo-lattice theory

    International Nuclear Information System (INIS)

    Bouguerra, Sabbah; Bou Malham, Ibrahim; Letellier, Pierre; Mayaffre, Alain; Turmine, Mireille

    2008-01-01

    Values of partial molar volumes at infinite dilution of 9 inorganic and 4 organic 1:1 electrolytes have been determined in (water + ethylammonium nitrate) (EAN) binary at 298.15 K throughout the composition scale. Our theoretical analysis shows that the values of partial molar volumes at infinite dilution of a solute in a binary are linked to those of the partial molar volumes of the components of mixed solvent. This applies to mixtures of molecular solvents as well as (water + ionic liquid) media. The use of the 'pseudo-lattice theory' of Bahe recently supplemented Varela can be used for calculations and to obtain information about the interactions between 1:1 electrolytes as solutes at infinite dilution and their concentrated saline environment. We show that the 'pseudo-lattice theory' allows accurate description of the behaviours of symmetrical tetraalkylammoniums bromide between the infinitely dilute state and concentrations higher than 2 mol . L -1

  15. Mixed convection in a nanofluid filled-cavity with partial slip subjected to constant heat flux and inclined magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Ismael, Muneer A. [Mechanical Engineering Department, Engineering College, University of Basrah, Basrah (Iraq); Mansour, M.A. [Department of Mathematics, Assuit University, Faculty of Science, Assuit (Egypt); Chamkha, Ali J. [Mechanical Engineering Department, Prince Mohammad Bin Fahd University, Al-Khobar 31952 (Saudi Arabia); Prince Sultan Endowment for Energy and Environment, Prince Mohammad Bin Fahd University, Al-Khobar 31952 (Saudi Arabia); Rashad, A.M., E-mail: am_rashad@yahoo.com [Department of Mathematics, Aswan University, Faculty of Science, Aswan 81528 (Egypt)

    2016-10-15

    Mixed convection in a lid-driven square cavity filled with Cu-water nanofluid and subjected to inclined magnetic field is investigated in this paper. Partial slip effect is considered along the lid driven horizontal walls. A constant heat flux source on the left wall is considered, meanwhile the right vertical wall is cooled isothermally. The remainder cavity walls are thermally insulted. A control finite volume method is used as a numerical appliance of the governing equations. Six pertinent parameters were studied these; the orientation of the magnetic field (Φ=0–360°), Richardson number (Ri=0.001–1000), Hartman number (Ha=0–100), the size and position of the heat source (B=0.2–0.8, D=0.3–0.7, respectively), nanoparticles volume fraction (ϕ=0.0–0.1), and the lid-direction of the horizontal walls (λ=±1) where the positive sign means lid-driven to the right while the negative sign means lid-driven to the left. The results show that the orientation and the strength of the magnetic field can play a significant role in controlling the convection under the effect of partial slip. It is also found that the natural convection decreases with increasing the length of the heat source for all ranges of the studied parameters, while it is do so due to the vertical distance up to Hartman number of 50, beyond this value the natural convection decreases with lifting the heat source narrower to the top wall. - Highlights: • Partial slip along moving walls of MHD cavity filled with nanofluid is considered. • The suppression exerted by the magnetic field decreases with its orientation. • Nusselt number is enhanced slightly with nanoparticles at shortest heat source. • Nusselt number is enhanced with nanoparticles at stronger magnetic field.

  16. Mixed convection in a nanofluid filled-cavity with partial slip subjected to constant heat flux and inclined magnetic field

    International Nuclear Information System (INIS)

    Ismael, Muneer A.; Mansour, M.A.; Chamkha, Ali J.; Rashad, A.M.

    2016-01-01

    Mixed convection in a lid-driven square cavity filled with Cu-water nanofluid and subjected to inclined magnetic field is investigated in this paper. Partial slip effect is considered along the lid driven horizontal walls. A constant heat flux source on the left wall is considered, meanwhile the right vertical wall is cooled isothermally. The remainder cavity walls are thermally insulted. A control finite volume method is used as a numerical appliance of the governing equations. Six pertinent parameters were studied these; the orientation of the magnetic field (Φ=0–360°), Richardson number (Ri=0.001–1000), Hartman number (Ha=0–100), the size and position of the heat source (B=0.2–0.8, D=0.3–0.7, respectively), nanoparticles volume fraction (ϕ=0.0–0.1), and the lid-direction of the horizontal walls (λ=±1) where the positive sign means lid-driven to the right while the negative sign means lid-driven to the left. The results show that the orientation and the strength of the magnetic field can play a significant role in controlling the convection under the effect of partial slip. It is also found that the natural convection decreases with increasing the length of the heat source for all ranges of the studied parameters, while it is do so due to the vertical distance up to Hartman number of 50, beyond this value the natural convection decreases with lifting the heat source narrower to the top wall. - Highlights: • Partial slip along moving walls of MHD cavity filled with nanofluid is considered. • The suppression exerted by the magnetic field decreases with its orientation. • Nusselt number is enhanced slightly with nanoparticles at shortest heat source. • Nusselt number is enhanced with nanoparticles at stronger magnetic field.

  17. Prevalent of root resorption of second molar adjustment the impacted third molar in prepiacal and panoramic radiographs

    Directory of Open Access Journals (Sweden)

    Mohammad Ebrahimi Saravi

    2013-10-01

    Full Text Available   Background and Aims: Impacted third molar reduces the bone level in the distal aspect of second molar, and sometimes it can lead to root resorption of the adjacent tooth. The purpose of this study was to determine this resorption using panoramic and periapical radiographs.   Materials and Methods: In this cross-sectional descriptive study 54 patient (28 men, 26 women above 15 years old with the average of 22 years in Oral and Maxillofacial Department of Tehran University were studied. A periapical radiography from the third molar and a panoramic radiograph were taken from each patient (Because of their routine use and evaluation of accuracy of panoramic compared with periapical, and the magnitude of the root resorption for the second molar was determined by 2 observers and written in a questionnaire. Data were analyzed using Fisher test.   Results: The prevalence of the root resorption of the second molar adjacent to the impacted third molar in the panoramic and the periapical radiographies, with respect to the limitation of the sample size were 46.3% and 31.5%, respectively, with 95% confidence(P>0.05. Most of these resorptions were in the cervical third of the second molar roots and in cases in which the third molars were mesially oriented or horizontal. There was also no significant difference between panoramic and periapical radiographs.   Conclusion: Due to the increased risk of the resorption of the second molar adjacent to the third molar, extraction of the impacted third molars, especiall y mesially oriented or horizontal ones are recommended.

  18. Thermal behaviour of pressure tube under fully and partially voided heating conditions using 19 pin fuel element simulator

    International Nuclear Information System (INIS)

    Yadav, Ashwini K.; Kumar, Ravi; Gupta, Akhilesh; Chatterjee, B.; Mukhopadhya, D.; Lele, H.G.

    2011-01-01

    In a nuclear reactor temperature can rise drastically during LOCA due to failure of heat transportation system and subsequently leads to mechanical deformations like sagging, ballooning and breaching of pressure tube. To understand the phenomenon an experiment has been carried out using 19 pin fuel element simulator. Main purpose of the experiment was to trace temperature profiles over the pressure tube, calandria tube and clad tubes of 220 MWe Indian Pressurised Heavy Water Reactor (IPHWR). The symmetrical heating of pressure tube of 1 m length was done through resistance heating of 19 pins under 13.5 kW power using a rectifier and the variation of temperatures over the circumference of pressure tube (PT), calandria tube (CT) and clad tubes were measured. The sagging of pressure tube was initiated at 460 deg C temperature and highest temperature attained was 650 deg C. The highest temperature attained by clad tubes was 680 deg C (over outer ring) and heat is dissipated to calandria vessel mainly due to radiation and natural convection. Again to simulate partially voided conditions, asymmetrical heating of pressure was carried out by injecting 8 kW power to upper 8 pins of fuel simulator. A maximum temperature difference of 295 deg C was observed over the circumference of pressure tube which highlights the magnitude of thermal stresses and its role in breaching of pressure tube under partially voided conditions. Integrity of pressure tube was retained during both symmetrical and asymmetrical heatup conditions. (author)

  19. Ceramic onlay for endodontically treated mandibular molar

    Directory of Open Access Journals (Sweden)

    Roopadevi Garlapati

    2014-01-01

    Full Text Available Restoration of endodontically treated teeth is important for the success of endodontic treatment. In full coverage restorations, maximum amount of tooth structure is compromised, so as to conserve the amount of tooth structure partial coverage restorations, can be preferred. This case report is on fabrication of a conservative tooth colored restoration for an endodontically treated posterior tooth. A 22-year-old male patient presented with pain in the mandibular left first molar. After endodontic treatment, composite material was used as postendodontic restoration. The tooth was then prepared to receive a ceramic onlay and bonded with self-adhesive universal resin cement. Ceramic onlay restoration was periodically examined up to 2 years.

  20. Excess molar volumes and refractive indices of (methoxybenzene+benzene, or toluene, or o-xylene, or m-xylene, or p-xylene, or mesitylene) binary mixtures between T=(288.15 to 303.15)K

    International Nuclear Information System (INIS)

    Al-Kandary, Jasem A.; Al-Jimaz, Adel S.; Abdul-Latif, Abdul-Haq M.

    2006-01-01

    Densities ρ and refractive indices n D for (anisole+benzene, or toluene, or o-xylene, or m-xylene or p-xylene or mesitylene) binary mixtures over the entire range of mole fraction, at temperatures (288.15, 293.15, 298.15, and 303.15)K and atmospheric pressure, have been measured. The excess molar volume V E and molar refraction deviation ΔR m , have been calculated and fitted to the Redlich-Kister polynomial relation to estimate the binary coefficients and standard errors. The excess molar volumes are positive for (anisole+mesitylene) binary mixtures and negative for (anisole+benzene, or toluene, or xylene isomers) binary mixtures at various temperatures. Partial molar volumes V-bar i and partial excess molar volumes V-bar i E have been also derived from the experimental data. The calculated values have been used to explain the dependency of intermolecular interaction between the mixing components on the alkyl substitution on benzene ring

  1. Octanol-Water Partition Coefficient from 3D-RISM-KH Molecular Theory of Solvation with Partial Molar Volume Correction.

    Science.gov (United States)

    Huang, WenJuan; Blinov, Nikolay; Kovalenko, Andriy

    2015-04-30

    The octanol-water partition coefficient is an important physical-chemical characteristic widely used to describe hydrophobic/hydrophilic properties of chemical compounds. The partition coefficient is related to the transfer free energy of a compound from water to octanol. Here, we introduce a new protocol for prediction of the partition coefficient based on the statistical-mechanical, 3D-RISM-KH molecular theory of solvation. It was shown recently that with the compound-solvent correlation functions obtained from the 3D-RISM-KH molecular theory of solvation, the free energy functional supplemented with the correction linearly related to the partial molar volume obtained from the Kirkwood-Buff/3D-RISM theory, also called the "universal correction" (UC), provides accurate prediction of the hydration free energy of small compounds, compared to explicit solvent molecular dynamics [ Palmer , D. S. ; J. Phys.: Condens. Matter 2010 , 22 , 492101 ]. Here we report that with the UC reparametrized accordingly this theory also provides an excellent agreement with the experimental data for the solvation free energy in nonpolar solvent (1-octanol) and so accurately predicts the octanol-water partition coefficient. The performance of the Kovalenko-Hirata (KH) and Gaussian fluctuation (GF) functionals of the solvation free energy, with and without UC, is tested on a large library of small compounds with diverse functional groups. The best agreement with the experimental data for octanol-water partition coefficients is obtained with the KH-UC solvation free energy functional.

  2. Human dental age estimation combining third molar(s) development and tooth morphological age predictors.

    Science.gov (United States)

    Thevissen, P W; Galiti, D; Willems, G

    2012-11-01

    In the subadult age group, third molar development, as well as age-related morphological tooth information can be observed on panoramic radiographs. The aim of present study was to combine, in subadults, panoramic radiographic data based on developmental stages of third molar(s) and morphological measurements from permanent teeth, in order to evaluate its added age-predicting performances. In the age range between 15 and 23 years, 25 gender-specific radiographs were collected within each age category of 1 year. Third molar development was classified and registered according the 10-point staging and scoring technique proposed by Gleiser and Hunt (1955), modified by Köhler (1994). The Kvaal (1995) measuring technique was applied on the indicated teeth from the individuals' left side. Linear regression models with age as response and third molar-scored stages as explanatory variables were developed, and morphological measurements from permanent teeth were added. From the models, determination coefficients (R (2)) and root-mean-square errors (RMSE) were calculated. Maximal-added age information was reported as a 6 % R² increase and a 0.10-year decrease of RMSE. Forensic dental age estimations on panoramic radiographic data in the subadult group (15-23 year) should only be based on third molar development.

  3. Heat capacities of aqueous polar aromatic compounds over a wide range of conditions. Part I: phenol, cresols, aniline, and toluidines

    International Nuclear Information System (INIS)

    Censky, Miroslav; Hnedkovsky, Lubomir; Majer, Vladimir

    2005-01-01

    The heat capacities of dilute aqueous solutions of phenol (hydroxybenzene), three cresols (2-, 3- and 4-methylhydroxybenzene), aniline (aminobenzene) and three toluidines (2-, 3- and 4-methylaminobenzene) were determined using a modified flow Picker-type high temperature calorimeter. The measurements were performed at temperatures between (303 and 623) K or 573 K for compounds containing hydroxy or amino group, respectively, and at several pressures up to 30 MPa. Standard heat capacities (partial molar heat capacities at infinite dilution) obtained from the experimental data exhibit a strong increase with temperature above 500 K consistent with the evolution of the standard volumes reported earlier. The data for aqueous phenol were used for testing several semiempiric models proposed for description of the standard thermodynamic properties of aqueous solutes. Their ability to reproduce the temperature and pressure dependence of standard heat capacities and to extrapolate towards higher conditions were examined

  4. Thermodynamics of proton dissociations from aqueous glycine at temperatures from 278.15 to 393.15 K, molalities from 0 to 1.0 mol . kg-1, and at the pressure 0.35 MPa: Apparent molar heat capacities and apparent molar volumes of glycine, glycinium chloride, and sodium glycinate

    International Nuclear Information System (INIS)

    Ziemer, S.P.; Niederhauser, T.L.; Merkley, E.D.; Price, J.L.; Sorenson, E.C.; McRae, B.R.; Patterson, B.A.; Origlia-Luster, M.L.; Woolley, E.M.

    2006-01-01

    We have measured the densities of aqueous solutions of glycine, glycine plus equimolal HCl, and glycine plus equimolal NaOH at temperatures 278.15 ≤ T/K ≤ 368.15, molalities 0.01 ≤ m/mol . kg -1 ≤ 1.0, and at p = 0.35 MPa, using a vibrating tube densimeter. We have also measured the heat capacities of these solutions at 278.15 ≤ T/K ≤ 393.15 and at the same m and p using a fixed-cell differential scanning calorimeter. We used the densities to calculate apparent molar volumes V φ and the heat capacities to calculate apparent molar heat capacities C p,φ for these solutions. We used our results and values of V φ (T, m) and C p,φ (T, m) for HCl(aq), NaOH(aq), NaCl(aq) from the literature to calculate parameters for Δ r C p,m (T, m) for the first and second proton dissociations from protonated aqueous cationic glycine. We then integrated this value of Δ r C p,m (T, m) in an iterative algorithm, using Young's Rule to account for the effects of speciation and chemical relaxation on the observed V φ and C p,φ of the solutions. This procedure yielded parameters for V φ (T, m) and C p,φ (T, m) for glycinium chloride {H 2 Gly + Cl - (aq)} and sodium glycinate {Na + Gly - (aq)} which successfully modeled our observed results. We have then calculated values of Δ r C p,m , Δ r H m , Δ r V m , and pQ a for the first and second proton dissociations from protonated aqueous glycine as functions of T and m

  5. Modeling of strongly heat-driven flow in partially saturated fractured porous media

    International Nuclear Information System (INIS)

    Pruess, K.; Tsang, Y.W.; Wang, J.S.Y.

    1985-01-01

    The authors have performed modeling studies on the simultaneous transport of heat, liquid water, vapor, and air in partially saturated fractured porous media, with particular emphasis on strongly heat-driven flow. The presence of fractures makes the transport problem very complex, both in terms of flow geometry and physics. The numerical simulator used for their flow calculations takes into account most of the physical effects which are important in multi-phase fluid and heat flow. It has provisions to handle the extreme non-linearities which arise in phase transitions, component disappearances, and capillary discontinuities at fracture faces. They model a region around an infinite linear string of nuclear waste canisters, taking into account both the discrete fractures and the porous matrix. From an analysis of the results obtained with explicit fractures, they develop equivalent continuum models which can reproduce the temperature, saturation, and pressure variation, and gas and liquid flow rates of the discrete fracture-porous matrix calculations. The equivalent continuum approach makes use of a generalized relative permeability concept to take into account the fracture effects. This results in a substantial simplification of the flow problem which makes larger scale modeling of complicated unsaturated fractured porous systems feasible. Potential applications for regional scale simulations and limitations of the continuum approach are discussed. 27 references, 13 figures, 2 tables

  6. Modeling of strongly heat-driven flow in partially saturated fractured porous media

    International Nuclear Information System (INIS)

    Pruess, K.; Tsang, Y.W.; Wang, J.S.Y.

    1984-10-01

    We have performed modeling studies on the simultaneous transport of heat, liquid water, vapor, and air in partially saturated fractured porous media, with particular emphasis on strongly heat-driven flow. The presence of fractures makes the transport problem very complex, both in terms of flow geometry and physics. The numerical simulator used for our flow calculations takes into account most of the physical effects which are important in multi-phase fluid and heat flow. It has provisions to handle the extreme non-linearities which arise in phase transitions, component disappearances, and capillary discontinuities at fracture faces. We model a region around an infinite linear string of nuclear waste canisters, taking into account both the discrete fractures and the porous matrix. From an analysis of the results obtained with explicit fractures, we develop equivalent continuum models which can reproduce the temperature, saturation, and pressure variation, and gas and liquid flow rates of the discrete fracture-porous matrix calculations. The equivalent continuum approach makes use of a generalized relative permeability concept to take into account for fracture effects. This results in a substantial simplification of the flow problem which makes larger scale modeling of complicated unsaturated fractured porous systems feasible. Potential applications for regional scale simulations and limitations of the continuum approach are discussed. 27 references, 13 figures, 2 tables

  7. A three-dimensional finite element analysis of molar distalization with a palatal plate, pendulum, and headgear according to molar eruption stage

    Science.gov (United States)

    Kang, Ju-Man; Park, Jae Hyun; Bayome, Mohamed; Oh, Moonbee; Park, Chong Ook; Mo, Sung-Seo

    2016-01-01

    Objective This study aimed to (1) evaluate the effects of maxillary second and third molar eruption status on the distalization of first molars with a modified palatal anchorage plate (MPAP), and (2) compare the results to the outcomes of the use of a pendulum and that of a headgear using three-dimensional finite element analysis. Methods Three eruption stages were established: an erupting second molar at the cervical one-third of the first molar root (Stage 1), a fully erupted second molar (Stage 2), and an erupting third molar at the cervical one-third of the second molar root (Stage 3). Retraction forces were applied via three anchorage appliance models: an MPAP with bracket and archwire, a bone-anchored pendulum appliance, and cervical-pull headgear. Results An MPAP showed greater root movement of the first molar than crown movement, and this was more noticeable in Stages 2 and 3. With the other devices, the first molar showed distal tipping. Transversely, the first molar had mesial-out rotation with headgear and mesial-in rotation with the other devices. Vertically, the first molar was intruded with an MPAP, and extruded with the other appliances. Conclusions The second molar eruption stage had an effect on molar distalization, but the third molar follicle had no effect. The application of an MPAP may be an effective treatment option for maxillary molar distalization. PMID:27668192

  8. MANAGEMENT OF MANDIBULAR THIRD MOLAR SURGERY TO PRESERVE PERIODONTAL HEALTH OF SECOND MOLAR

    Directory of Open Access Journals (Sweden)

    Elitsa G. Deliverska

    2017-06-01

    Full Text Available Background: Extraction of impacted third molar violates surrounding soft and bony tissues. Various surgical approaches and surgical technics have an important impact on the periodontal health of the adjacent second molar. Purpose: The aim of this review is to analyse the causes that can affect postoperative periodontal outcomes for the mandibular second molars (LM2 adjacent to the impacted/ semi impacted mandibular third molars (LM3. Material and Methods: Electronic searches were conducted through the MEDLINE (PubMed, Scopus, etc. databases to screen all relevant articles published from inception to April 2017. Results: Different flap techniques had no significant impact on the probing depth reduction or on the clinical attachment level of LM2. Szmyd and paramarginal flap designs may be the most effective in reducing the probing depth after third molar surgery, and the envelope flap may be the least effective. Use of bone substitutes and guided tissue regeneration therapy has been proposed, to eliminate or prevent these periodontal defects, but there is still no consensus on their predictability or clinical benefit. Higher costs and the risk of postoperative inflammatory complications should also be taken into proper account, as with any surgical procedure. “Orthodontic extraction” is indicated for that impacted M3 that present a high risk of postoperative periodontal defects at the distal aspect of adjacent M2. Conclusion: Risk factors associated with bone loss following lower third molar extraction includes age, the direction of the eruption, preoperative bone defects, and resorbtion of the LM2 root surface. Prevention of such periodontal defects continues to challenge clinicians.

  9. Apparent and partial molal heat capacities of aqueous rare earth nitrate solutions at 250C

    International Nuclear Information System (INIS)

    Spedding, F.H.; Baker, J.L.; Walters, J.P.

    1979-01-01

    Specific heats of aqueous solutions of the trinitrates of La, Pr, Nd, Sm, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu were measured from 0.1 m to saturation at 25 0 C. Apparent molal heat capacities, phi/sub cp/, were calculated for these solutions, and empirical polynomial equations were obtained which expressed phi/sub cp/ as a function of m/sup 1/2/ for each salt. The partial molal heat capacities of the solvent, anti C 1 /sub p/, and solute, anti C 2 /sub p/, were calculated from these equations. Unlike chloride and perchlorate data reported earlier, values of anti C 1 /sub p/ for nitrate solutions across the rare earth series did not show a two series effect. Instead, anti C 1 /sub p/ values at lower concentrations (0.5 and 1.0 m) appear correlated with reported first formation constants for rare earth-nitrate complexes. 31 references, 9 figures, 2 tables

  10. 3D magneto-convective heat transfer in CNT-nanofluid filled cavity under partially active magnetic field

    Science.gov (United States)

    Al-Rashed, Abdullah A. A. A.; Kolsi, Lioua; Oztop, Hakan F.; Aydi, Abdelkarim; Malekshah, Emad Hasani; Abu-Hamdeh, Nidal; Borjini, Mohamed Naceur

    2018-05-01

    A computational study has been performed to investigate the effects of partially active magnetic field on natural convection heat transfer in CNT-nanofluid filled and three-dimensional differentially heated closed space. Two cases are considered to see this effect as magnetic field is applied to upper half (Case I) and lower half (Case II) while remaining walls are insulated. The finite volume method is used to solve governing equations and results are obtained for different governing parameters as Hartmann number (0 ≤ Ha ≤ 100), nanoparticle volume fraction (0 ≤ φ ≤ 0.05) and height of the active zone (0 ≤ LB ≤ 1). It is found that location of magnetic field plays an important role even at the same Hartmann number. Thus, it can be a good parameter to control heat and fluid flow inside the closed space.

  11. Incidence of root canal treatment of second molars following adjacent impacted third molar extraction

    Directory of Open Access Journals (Sweden)

    Yener Oguz

    2016-03-01

    Conclusion: Although the incidence is minimal, iatrogenic subluxation injuries occurring during the surgical removal of impacted third molars can lead to pulpal complications and a requirement for root canal treatment of adjacent second molars.

  12. Densities and apparent molar volumes of aqueous LiI solutions at temperatures from (296 to 600) K and at pressures up to 30 MPa

    International Nuclear Information System (INIS)

    Abdulagatov, I.M.; Azizov, N.D.

    2004-01-01

    Densities of five aqueous LiI solutions (0.0906, 0.2832, 0.6621, 1.6046, and 3.0886) mol . kg -1 H 2 O were measured in the liquid phase with a constant-volume piezometer immersed in a precision liquid thermostat. Measurements were made along various isotherms between (296.95 and 600.25) K. The range of pressure was (0.1 to 30) MPa. The total uncertainty of density, pressure, temperature, and concentration measurements was estimated to be less than 0.06%, 0.05%, 15 mK, and 0.014%, respectively. To check and confirm the accuracy of the measurements, (p,V m ,T,x) data were taken for pure water at selected temperatures and pressures. Experimental and calculated (IAPWS formulation) densities for pure water show excellent agreement within their experimental uncertainties (average absolute deviation is 0.02%). Values of saturated densities were determined by extrapolating experimental p - ρ data to the vapour pressure at fixed temperature and composition using a linear interpolating equation. Apparent molar volumes were derived using measured values of density for solutions and pure water. The apparent molar volumes were extrapolated to zero concentration (m → 0) to yield partial molar volumes of electrolyte (LiI) at infinite dilution. The temperature, pressure, and concentration dependence of apparent and partial molar volumes was studied. The measured values of density, apparent and partial molar volume were compared with data reported in the literature by other authors. A polynomial type of equation of state for specific volume was obtained as a function of temperature, pressure, and composition by a least-squares method using the experimental data. The average absolute deviation (AAD) between measured and calculated values from this polynomial equation for density was 0.065%

  13. Analysis of the passive heat removal enhancement for AP1000 containment due to the partially wetted coverage

    Energy Technology Data Exchange (ETDEWEB)

    Li, Cheng, E-mail: 510395453@qq.com [State Nuclear Power Technology Research & Development Center, 102209 Beijing (China); Li, Le [Tsinghua University, Institute of Nuclear and New Energy Technology, 100084 Beijing (China); Li, Junming [Tsinghua University, Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Thermal Engineering, Beijing 100084 (China); Zhang, Yajun [Tsinghua University, Institute of Nuclear and New Energy Technology, 100084 Beijing (China); Li, Zhihui [State Nuclear Power Technology Research & Development Center, 102209 Beijing (China)

    2017-03-15

    Highlights: • Heat removal by steam condensation, thermal conduction and evaporation is the most important scheme for AP1000 PCCS. Traditionally, studies on containment wall condensation and evaporation have been widely made, while it lacks studies on the shell two-dimension (2-D) thermal conduction. Currently, based on the known heat and mass transfer correlations and the phenomenon from water wetted coverage test, the physical model for 2-D thermal conduction is given and numerical simulation is then made. By discussions, it forms the following highlights. • The partially wetted surface can enhance the whole heat transfer process (including inner condensation, wall thermal conduction and outside cooling) and the maximum enhancement factor can be as large as 63%. There is an enhancement peak at around dry strip fraction a = 90%. When L is less than 0.03 m, its influence on heat transfer is small and the enhancement is mainly affected by dry coverage. However, for larger L, both α and L contribute much to larger enhancement. • Location at the spring line is often used for safety analysis and the dry strip fraction there for AP1000 is mainly at 10%–80%. Accordingly, further analysis is made on L (0.03 < L < 0.3) and a fitting expression is given for α = 10%–80%. It could be used to improve the corresponding software and it could also be used for containment scaling-down criteria analysis. - Abstract: AP1000 containment uses the water film evaporation, coupled with containment inner condensation, to remove the core decay heat. However, water film cannot fully cover heat transfer surface and dry-wetted strips appear. As a result, heat transfer within the containment shell is a two-dimension thermal conduction. Current work numerically studied the AP1000 heat removal enhancement due to the partially wetted coverage phenomenon. It used the evaporation and condensation boundary conditions and Fluent software to calculate the local heat fluxes and their

  14. Analysis of the passive heat removal enhancement for AP1000 containment due to the partially wetted coverage

    International Nuclear Information System (INIS)

    Li, Cheng; Li, Le; Li, Junming; Zhang, Yajun; Li, Zhihui

    2017-01-01

    Highlights: • Heat removal by steam condensation, thermal conduction and evaporation is the most important scheme for AP1000 PCCS. Traditionally, studies on containment wall condensation and evaporation have been widely made, while it lacks studies on the shell two-dimension (2-D) thermal conduction. Currently, based on the known heat and mass transfer correlations and the phenomenon from water wetted coverage test, the physical model for 2-D thermal conduction is given and numerical simulation is then made. By discussions, it forms the following highlights. • The partially wetted surface can enhance the whole heat transfer process (including inner condensation, wall thermal conduction and outside cooling) and the maximum enhancement factor can be as large as 63%. There is an enhancement peak at around dry strip fraction a = 90%. When L is less than 0.03 m, its influence on heat transfer is small and the enhancement is mainly affected by dry coverage. However, for larger L, both α and L contribute much to larger enhancement. • Location at the spring line is often used for safety analysis and the dry strip fraction there for AP1000 is mainly at 10%–80%. Accordingly, further analysis is made on L (0.03 < L < 0.3) and a fitting expression is given for α = 10%–80%. It could be used to improve the corresponding software and it could also be used for containment scaling-down criteria analysis. - Abstract: AP1000 containment uses the water film evaporation, coupled with containment inner condensation, to remove the core decay heat. However, water film cannot fully cover heat transfer surface and dry-wetted strips appear. As a result, heat transfer within the containment shell is a two-dimension thermal conduction. Current work numerically studied the AP1000 heat removal enhancement due to the partially wetted coverage phenomenon. It used the evaporation and condensation boundary conditions and Fluent software to calculate the local heat fluxes and their

  15. Vapor pressures and standard molar enthalpies, entropies, and Gibbs free energies of sublimation of 2,4- and 3,4-dinitrobenzoic acids

    International Nuclear Information System (INIS)

    Vecchio, Stefano; Brunetti, Bruno

    2009-01-01

    The vapor pressures of the solid and liquid 2,4- and 3,4-dinitrobenzoic acids were determined by torsion-effusion and thermogravimetry under both isothermal and non-isothermal conditions, respectively. From the temperature dependence of vapor pressure derived by the experimental torsion-effusion and thermogravimetry data the molar enthalpies of sublimation Δ cr g H m 0 ( ) and vaporization Δ l g H m 0 ( ) were determined, respectively, at the middle of the respective temperature intervals. The melting temperatures and the molar enthalpies of fusion of these compounds were measured by d.s.c. Finally, the results obtained by all the methods proposed were corrected at the reference temperature of 298.15 K using the estimated heat capacity differences between gas and liquid for vaporization experiments and the estimated heat capacity differences between gas and solid for sublimation experiments. Therefore, the averages of the standard (p o = 0.1 MPa) molar enthalpies, entropies and Gibbs free energies of sublimation at 298.15 K, have been derived.

  16. Hypomineralized Second Primary Molars as Predictor of Molar Incisor Hypomineralization

    Science.gov (United States)

    Negre-Barber, A.; Montiel-Company, J. M.; Boronat-Catalá, M.; Catalá-Pizarro, M.; Almerich-Silla, J. M.

    2016-01-01

    Molar incisor hypomineralization (MIH) is a developmental defect of dental enamel that shares features with hypomineralized second primary molars (HSPM). Prior to permanent tooth eruption, second primary molars could have predictive value for permanent molar and incisor hypomineralization. To assess this possible relationship, a cross-sectional study was conducted in a sample of 414 children aged 8 and 9 years from the INMA cohort in Valencia (Spain). A calibrated examiner (linear-weighted Kappa 0.83) performed the intraoral examinations at the University of Valencia between November 2013 and 2014, applying the diagnostic criteria for MIH and HSPM adopted by the European Academy of Paediatric Dentistry. 100 children (24.2%) presented MIH and 60 (14.5%) presented HSPM. Co-occurrence of the two defects was observed in 11.1% of the children examined. The positive predictive value was 76.7% (63.9–86.6) and the negative predictive value 84.7% (80.6–88.3). The positive likelihood ratio (S/1-E) was 10.3 (5.9–17.9) and the negative likelihood ratio (1-S/E) 0.57 (0.47–0.68). The odds ratio was 18.2 (9.39–35.48). It was concluded that while the presence of HSPM can be considered a predictor of MIH, indicating the need for monitoring and control, the absence of this defect in primary dentition does not rule out the appearance of MIH. PMID:27558479

  17. Plasminogen and angiostatin interact with heat shock proteins.

    Science.gov (United States)

    Dudani, Anil K; Mehic, Jelica; Martyres, Anthony

    2007-06-01

    Previous studies from this laboratory have demonstrated that plasminogen and angiostatin bind to endothelial cell (EC) surface-associated actin via their kringles in a specific manner. Heat shock proteins (hsps) like hsp 27 are constitutively expressed by vascular ECs and regulate actin polymerization, cell growth, and migration. Since many hsps have also been found to be highly abundant on cell surfaces and there is evidence that bacterial surface hsps may interact with human plasminogen, the purpose of this study was to determine whether human plasminogen and angiostatin would interact with human hsps. ELISAs were developed in our laboratory to assess these interactions. It was observed that plasminogen bound to hsps 27, 60, and 70. In all cases, binding was inhibited (85-90%) by excess (50 mM) lysine indicating kringle involvement. Angiostatin predominantly bound to hsp 27 and to hsp 70 in a concentration- and kringle-dependent manner. As observed previously for actin, there was concentration-dependent inhibition of angiostatin's interaction with hsp 27 by plasminogen. In addition, 30-fold molar excess actin inhibited (up to 50%), the interaction of plasminogen with all hsps. However, 30-fold molar excess actin could only inhibit the interaction of angiostatin with hsp 27 by 15-20%. Collectively, these data indicate that (i) while plasminogen interacts specifically with hsp 27, 60, and 70, angiostatin interacts predominantly with hsp 27 and to some extent with hsp 70; (ii) plasminogen only partially displaces angiostatin's binding to hsp 27 and (iii) actin only partially displaces plasminogen/angiostatin binding to hsps. It is conceivable therefore that surface-associated hsps could mediate the binding of these ligands to cells like ECs.

  18. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures

    Science.gov (United States)

    Creugers, N. H. J.; Witter, D. J.; Van 't Spijker, A.; Gerritsen, A. E.; Kreulen, C. M.

    2010-01-01

    Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n = 25) were compared with subjects with shortened dental arches without extension (n = 74) and with subjects who had worn a mandibular extension removable partial denture in the past (n = 19). Subjects with complete dentitions (n = 72) were controls. Data were collected at baseline and at 3-, 6-, and 9-year observations. Results. Occlusal activity in terms of reported awareness of bruxism and occlusal tooth wear of lower anterior teeth did not differ significantly between the groups. In contrast, occlusal tooth wear of premolars in shortened dental arches with or without extension dentures was significantly higher than in the controls. Differences amongst groups with respect to signs and symptoms related to temporomandibular disorders were not found. Occlusal support of the dentures did not influence anterior spatial relationship. Occlusal contacts of the denture teeth decreased from 70% for second premolars via 50% for first molars, to 30% for second molars. Conclusions. Mandibular distal extension removable partial dentures in moderate shortened dental arches had no effects on occlusion and temporomandibular function. PMID:20671961

  19. Experimental study on heat transfer enhancement of laminar ferrofluid flow in horizontal tube partially filled porous media under fixed parallel magnet bars

    Energy Technology Data Exchange (ETDEWEB)

    Sheikhnejad, Yahya; Hosseini, Reza, E-mail: hoseinir@aut.ac.ir; Saffar Avval, Majid

    2017-02-15

    In this study, steady state laminar ferroconvection through circular horizontal tube partially filled with porous media under constant heat flux is experimentally investigated. Transverse magnetic fields were applied on ferrofluid flow by two fixed parallel magnet bar positioned on a certain distance from beginning of the test section. The results show promising notable enhancement in heat transfer as a consequence of partially filled porous media and magnetic field, up to 2.2 and 1.4 fold enhancement were observed in heat transfer coefficient respectively. It was found that presence of both porous media and magnetic field simultaneously can highly improve heat transfer up to 2.4 fold. Porous media of course plays a major role in this configuration. Virtually, application of Magnetic field and porous media also insert higher pressure loss along the pipe which again porous media contribution is higher that magnetic field. - Highlights: • Porous media can improve the coefficient of heat transfer up to 2.2 fold. • Both porous media and Nano particles have undesired pressure drop effect. • Application of both porous media and magnetic field in ferrofluid flow will result in significant enhancement in heat transfer up to 2.4 fold. • Magnet bar effect is mainly restricted to approximately one fourth of the test section. • Diluted Ferrofluids 2%, results in over 1.4 fold enhancement in heat transfer coefficient.

  20. CANINE ECTOPIC TREATMENT WITH FIRST MOLAR EXTRACTION

    Directory of Open Access Journals (Sweden)

    Angelica Margo

    2015-06-01

    Full Text Available Decision to extract or not and the type of tooth must be analyzed carefully in orthodontic treatment. Preferable tooth to be extracted was the tooth with large caries or restoration. Usually the type of tooth to be extracted was second molar (if the third molar appears, incisor, first molar, and combination of several teeth. Orthodontic treatment with molar extraction is more difficult to treat and the result is usually compromise. There are several considerations in extracting first molar such as tooth with large caries or restoration, hypoplasia, periapical disease, large discrepancy, high maxilla-mandibular plane angle, and cases with anterior open bite. Nowadays, orthodontic cases with molar extraction do not prolong the treatment time compared to premolar extraction case, but the anchorage system must be considered carefully. The present case was treated with extraction of first molar to solve anterior crowding with maximum anchorage at the upper jaw and using Nance Holding Appliance.

  1. Molar Incisiv Hypomineralisasjon - MIH Litteraturstudie

    OpenAIRE

    Khan, Aisha Farnaz

    2017-01-01

    Introduksjon: MIH er definert som emaljehypomineralisering av systemisk opprinnelse der 1 til 4 av første permanente molarer er rammet. Incisiver er også ofte affiserte. Hensikten med denne litteraturstudien er å lage en oversikt over, og vurdere tilgjengelig litteratur om MIH, og bruke litteraturen som bakgrunn for å utarbeide en informasjonsbrosjyre om MIH. Materiale og metode: Det ble utført et elektronisk søk i PubMed med søkestrengene ”Molar incisor hypomineralization MIH” og ”Molar inci...

  2. Expressly fabricated molar tube bases: enhanced adhesion.

    Science.gov (United States)

    Sharma, Tarun; Phull, Tarun Singh; Rana, Tarun; Kumar, Varun

    2014-06-01

    Clinicians, Orthodontists and their patients' parents often expect the best results in the shortest time span possible. Orthodontic bonding of molar tubes has been an acceptable risk in a modern era of refined biomaterials and instrumentation. Although many orthodontists still prefer banding to bonding, it is the failure rate of the tubes on molars which accounts to an impedance in molar bonding. One of the reasons for molar attachment failures is attributed to improper adaptation of the buccal tube base with or without increased thickness of composite. Merits of banding the second molars especially when these are the terminal teeth for anchorage have been overemphasized in the literature. The present article presents a simple and relatively less time consuming technique of preparing molar tubes to be bonded on tooth surfaces which may be quite difficult to isolate especially for bonding, for example, mandibular second molars. The increased surface area of the composite scaffold helps not only in enhanced bond strength but also serves to reduce the incidence of plaque accumulation given the dexterity of invitro preparation. The removal of the occlusal part of the molar tube scaffold helps in prevention of open / raised bite tendencies. The present innovation, therefore, is not merely serendipity but a structured technique to overcome a common dilemma for the clinical orthodontist. The present dictum of banding being superior to molar tube bonding may prove to be futile with trendsetting molar attachments. It is also an established fact that bonding proves to be a lesser expensive modality when compared to banding procedures.

  3. Permanent molars: Delayed development and eruption

    Directory of Open Access Journals (Sweden)

    Arathi R

    2006-05-01

    Full Text Available Delayed development and eruption of all the permanent molars is a rare phenomenon, which can cause disturbance in the developing occlusion. The eruption of permanent first and second molars is very important for the coordination of facial growth and for providing sufficient occlusal support for undisturbed mastication. In the case described, the first permanent molars were delayed in their development and were seen erupting at the age of nine and a half years. Severe disparity between the left and the right side of the dentition with respect to the rate of development of molars were also present.

  4. Má oclusão de Classe I com biprotrusão e ausência dos primeiros molares inferiores Angle Class I malocclusion with bimaxillary dental protrusion and missing mandibular first molars

    Directory of Open Access Journals (Sweden)

    Aldino Puppin Filho

    2011-12-01

    Full Text Available O presente relato de caso descreve o tratamento ortodôntico de uma paciente de 24 anos de idade, portadora de má oclusão de Classe I de Angle, com protrusão dos incisivos superiores e inferiores, além de perda recente dos primeiros molares inferiores. O tratamento idealizado envolveu a exodontia dos primeiros pré-molares superiores, aliada ao fechamento dos espaços presentes na arcada inferior. O resultado obtido demonstra a necessidade de planos de tratamento individualizados e a importância dos conceitos biomecânicos para movimentar adequadamente os dentes. Esse caso clínico foi apresentado à Diretoria do Board Brasileiro de Ortodontia e Ortopedia Facial (BBO, representando a categoria livre escolha, como parte dos requisitos para obtenção do título de Diplomado pelo BBO.This case report describes the orthodontic treatment of a 24-year-old patient presenting with Angle Class I malocclusion, bimaxillary dental protrusion and recent loss of mandibular molars. Treatment involved extraction of the maxillary first premolars and closing of mandibular first molar spaces. Treatment outcomes demonstrate the need for individualized treatment planning and highlight the key role played by biomechanical concepts in achieving proper orthodontic tooth movement. This case was presented to the Brazilian Board of Orthodontics and Facial Orthopedics (BBO as representative of the free choice category in partial fulfillment of the requirements for obtaining the BBO Diploma.

  5. Heat and Mass Transport in Heat Pipe Wick Structures

    OpenAIRE

    Iverson, B. D.; Davis, T. W.; Garimella, S V; North, M. T.; Kang, S.

    2007-01-01

    Anovel experimental approach is developed for characterizing the performance of heat pipe wick structures. This approach simulates the actual operation of wick structures in a heat pipe. Open, partially submerged, sintered copper wicks of varying pore size are studied under the partially saturated conditions found in normal heat pipe operation. A vertical wick orientation, where the capillary lift is in opposition to gravity, is selected to test the wicks under the most demanding conditions. ...

  6. Excess molar volumes and isentropic compressibility of binary systems {trioctylmethylammonium bis(trifluoromethysulfonyl)imide + methanol or ethanol or 1-propanol} at different temperatures

    International Nuclear Information System (INIS)

    Sibiya, P.N.; Deenadayalu, N.

    2008-01-01

    This paper reports measurements of densities for the binary systems of an ionic liquid and an alkanol at T = (298.15, 303.15, and 313.15) K. The IL is trioctylmethylammonium bis(trifluoromethylsulfonyl)imide [OMA] + [Tf 2 N] - and the alkanols are methanol, or ethanol, or 1-propanol. The speed of sound at T = 298.15 K for the same binary systems was also measured. The excess molar volumes and the isentropic compressibilities for the above systems were then calculated from the experimental densities and the speed of sound, respectively. Redlich-Kister smoothing polynomial equation was used to fit the excess molar volume and the deviation in isentropic compressibility data. The partial molar volumes were determined from the Redlich-Kister coefficients. For all the systems studied, the excess molar volumes have both negative and positive values, while the deviations in isentropic compressibility are negative over the entire composition range

  7. Reaction phenomena of catalytic partial oxidation of methane under the impact of carbon dioxide addition and heat recirculation

    International Nuclear Information System (INIS)

    Chen, Wei-Hsin; Lin, Shih-Cheng

    2015-01-01

    The reaction phenomena of CPOM (catalytic partial oxidation of methane) in a Swiss-roll reactor are studied numerically where a rhodium-based catalyst bed is embedded at the center of the reactor. CO 2 is added into the feed gas and excess enthalpy recovery is performed to evaluate their influences on CPOM performance. In the study, the mole ratio of O 2 to CH 4 (O 2 /CH 4 ratio) is fixed at 0.5 and the mole ratio of CO 2 to O 2 (CO 2 /O 2 ratio) is in the range of 0–2. The results reveal that CO 2 addition into the influent has a slight effect on methane combustion, but significantly enhances dry reforming and suppresses steam reforming. The reaction extents of steam reforming and dry reforming in CPOM without heat recovery and CO 2 addition are in a comparable state. Once CO 2 is added into the feed gas, the dry reforming is enhanced, thereby dominating CH 4 consumption. Compared to the reactor without excess enthalpy recovery, heat recirculation drastically increases the maximum reaction temperature and CH 4 conversion in the catalyst bed; it also intensifies the H 2 selectivity, H 2 yield, CO 2 conversion, and syngas production rate. The predictions indicate that the heat recirculation is able to improve the syngas formation up to 45%. - Highlights: • Catalytic partial oxidation of methane with CO 2 addition and heat recovery is studied. • CO 2 addition has a slight effect on methane combustion. • CO 2 addition significantly enhances dry reforming and suppresses steam reforming. • Dry reforming dominates CH 4 consumption when CO 2 addition is large. • Heat recirculation can improve the syngas formation up to 45%

  8. The determination of molar volumes of uranous nitrate and nitric acid in systems of U(NO3)4-HNO3-H2O and U(NO3)4-HNO3-30% TBP kerosene

    International Nuclear Information System (INIS)

    Tao Chengying

    1986-01-01

    The data of molar volumes of uranous nitrate and nitric acid are necessary for the calculation of the changes in phase volume during the extraction in U(NO 3 ) 4 -HNO 3 /30%TBP-kerosene system. However, the data of the partial molar volume of U(NO 3 ) 4 are not available in literature. In the present work, the molar volumes of U(NO 3 ) 4 and HNO 3 are calculated by linear fitting of the experimental data. The result of the molar volume of HNO 3 is consistent with those in literature

  9. Specific heats of degenerate ideal gases

    OpenAIRE

    Caruso, Francisco; Oguri, Vitor; Silveira, Felipe

    2017-01-01

    From arguments based on Heisenberg's uncertainty principle and Pauli's exclusion principle, the molar specific heats of degenerate ideal gases at low temperatures are estimated, giving rise to values consistent with the Nerst-Planck Principle (third law of Thermodynamics). The Bose-Einstein condensation phenomenon based on the behavior of specific heat of massive and non-relativistic boson gases is also presented.

  10. Mini-implant-supported Molar Distalization

    Directory of Open Access Journals (Sweden)

    Amit Goyal

    2012-01-01

    Full Text Available Temporary anchorage devices popularly called mini-implants or miniscrews are the latest addition to an orthodontist′s armamentarium. The following case report describes the treatment of a 16-year-old girl with a pleasant profile, moderate crowding and Angle′s Class II molar relationship. Maxillary molar distalization was planned and mini-implants were used to preserve the anterior anchorage. After 13 months of treatment, Class I molar and canine relation was achieved bilaterally and there was no anterior proclination. Thus, mini-implants provide a viable option to the clinician to carry out difficult tooth movements without any side effects.

  11. PERBEDAAN TOPICAL FLUORIDE APPLICATION DAN FISSURE SEALANT DALAM MENCEGAH KARIES PADAGIGI MOLAR SATU

    Directory of Open Access Journals (Sweden)

    Pawarti Pawarti

    2017-07-01

    Full Text Available Abstract: Topical Fluoride Application And Fissure Sealant To Prevent Dental Caries Permanent First Molars. Anatomy pits and fissures of teeth are caries initiation vulnerable areas of the permanent molars that grow at the age of 6 years where children can not perform oral hygiene. Caries prevention can be done by closing the pits and fissures or application of fluoride (topical fluoride application on the surface of the teeth. The purpose of this study was to analyze the difference fissure sealants and topical application of fluoride to prevent dental caries of first permanent molars. This study was a quasi-experimental study with time series, a sample was taken by purposive 117-second grade students of SDN District of North Pontianak. Data were analyzed using t-test. The result showed that fissure sealant more effective in caries prevention of first permanent molar than topical fluoride application where there were none caries teeth after and month fissure sealant, 25% sealant partially off and 11% fully off. Teeth that have done fluoride after 6 months of 3.9% of dental caries, the eighth month of 5.4% of dental caries. There was a significant difference between the effectiveness of fissure sealants with topical application of fluoride to prevent dental caries in first permanent molars p-value < 0.05, after 6-month p-value: 0.004 and after 8-month p-value: 0.001. Abstrak: Topical Fluoride Application Dan Fissure Sealant Untuk Mencegah Karies Pada Gigi Molar Satu Permanen. Anatomi pit dan fisura gigi merupakan daerah rentan inisiasi karies gigi molar satu permanen yang tumbuh pada usia 6 tahun anak belum bisa melakukan kebersihan mulutnya. Pencegahan karies dapat dilakukan dengan cara menutup pit dan fissure atau pengolesan fluor (topical fluoride application pada permukaan gigi. Tujuan penelitian ini untuk menganalisis perbedaan efektivitas fissure sealant dan topical fluoride application untuk mencegah karies gigi molar satu permanen anak

  12. Influence of unilateral maxillary first molar extraction treatment on second and third molar inclination in Class II subdivision patients

    NARCIS (Netherlands)

    Livas, Christos; Pandis, Nikolaos; Booij, Johan Willem; Halazonetis, Demetrios J.; Katsaros, Christos; Ren, Yijin

    Objective: To assess the maxillary second molar (M2) and third molar (M3) inclination following orthodontic treatment of Class II subdivision malocclusion with unilateral maxillary first molar (M1) extraction. Materials and Methods: Panoramic radiographs of 21 Class II subdivision adolescents (eight

  13. Relationship between partial and average atomic volumes of components in Au-Ni alloys%Au-Ni合金中组元的平均原子体积和偏摩尔体积的关系

    Institute of Scientific and Technical Information of China (English)

    谢佑卿

    2011-01-01

    在系统合金科学框架中建立有关无序合金的平均摩尔性质(体积和势能)的函数.通过对这些函数进行推导,可以得到平均摩尔体积函数、偏摩尔体积函数及派生出与成分相关的函数.在组元的偏摩尔性质和平均摩尔性质之间的普适方程、差分方程、在偏摩尔性质和平均摩尔性质之间不同参数的约束方程和普适的Gibbs-Duhem公式.可以证明从合金平均摩尔性质的不同函数计算的偏摩尔性质是相等的,但总体来说偏摩尔性质不等于给定组元的平均摩尔性质,即偏摩尔性质不能代表相应组元的摩尔性质.通过计算Au-Ni系中组元的偏摩尔体积和平均原子体积以及合金的平均原子体积,证明所建立的公式和函数的正确性.%In the framework of systematic science of alloys,the average molar property (volume and potential energy) functions of disordered alloys were established.From these functions,the average molar property functions,partial molar property functions,derivative functions with respect to composition,general equation of relationship between partial and average molar properties of components,difference equation and constraining equation of different values between partial and average molar properties,as well as general Gibbs-Duhem formula were derived.It was proved that the partial molar properties calculated from various combinative functions of average molar properties of alloys are equal,but in general,the partial molar properties are not equal to the average molar properties of a given component.This means that the partial molar properties cannot represent the corresponding properties of the component.All the equations and functions established in this work were proved to be correct by calculating the results of partial and average atomic volumes of components as well as average atomic volumes of alloys in the Au-Ni system.

  14. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures

    Directory of Open Access Journals (Sweden)

    N. H. J. Creugers

    2010-01-01

    Full Text Available Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n=25 were compared with subjects with shortened dental arches without extension (n=74 and with subjects who had worn a mandibular extension removable partial denture in the past (n=19. Subjects with complete dentitions (n=72 were controls. Data were collected at baseline and at 3-, 6-, and 9-year observations. Results. Occlusal activity in terms of reported awareness of bruxism and occlusal tooth wear of lower anterior teeth did not differ significantly between the groups. In contrast, occlusal tooth wear of premolars in shortened dental arches with or without extension dentures was significantly higher than in the controls. Differences amongst groups with respect to signs and symptoms related to temporomandibular disorders were not found. Occlusal support of the dentures did not influence anterior spatial relationship. Occlusal contacts of the denture teeth decreased from 70% for second premolars via 50% for first molars, to 30% for second molars. Conclusions. Mandibular distal extension removable partial dentures in moderate shortened dental arches had no effects on occlusion and temporomandibular function.

  15. Morphologic study of the maxillary molars. Part II: Internal anatomy.

    Science.gov (United States)

    Pécora, J D; Woelfel, J B; Sousa Neto, M D; Issa, E P

    1992-01-01

    The internal anatomy of three hundred and seventy (370) decalcified and cleared human maxillary molars was studied. Seventy-five percent of the first molars, 58% of the second molars and 68% of the third molars studied presented three (3) root canals and 25% of the first molars, 42% of the second molars and 32% of the third molars presented four (4) root canals. The authors observed that the incidence of two root canals in the mesiobuccal root was higher in second maxillary molars than in first maxillary molars.

  16. Pulpectomy procedures in primary molar teeth

    OpenAIRE

    Hany Mohamed Aly Ahmed

    2014-01-01

    Premature loss of primary molars can cause a number of undesirable consequences including loss of arch length, insufficient space for erupting premolars and mesial tipping of the permanent molars. Pulpectomy of primary molar teeth is considered as a reasonable treatment approach to ensure either normal shedding or a long-term survival in instances of retention. Despite being a more conservative treatment option than extraction, efficient pulpectomy of bizarre and tortuous root canals encased ...

  17. Vapor pressures and standard molar enthalpies, entropies and Gibbs energies of sublimation of two hexachloro herbicides using a TG unit

    International Nuclear Information System (INIS)

    Vecchio, Stefano

    2010-01-01

    The vapor pressures above the solid hexachlorobenzene (HCB) and above both the solid and liquid 1,2,3,4,5,6-hexachlorocyclohexane (lindane) were determined in the ranges 332-450 K and 347-429 K, respectively, by measuring the mass loss rates recorded by thermogravimetry under both isothermal and nonisothermal conditions. The results obtained were compared with those taken from literature. From the temperature dependence of vapor pressure derived by the experimental thermogravimetry data the molar enthalpies of sublimation Δ cr g H m o ( ) were selected for HCB and lindane as well as the molar enthalpy of vaporization Δ l g H m o ( ) for lindane only, at the middle of the respective temperature intervals. The melting temperatures and the molar enthalpies of fusion Δ cr l H m o (T fus ) of lindane were measured by differential scanning calorimetry. Finally, the standard molar enthalpies of sublimation Δ cr g H m o (298.15 K) were obtained for both chlorinated compounds at the reference temperature of 298.15 K using the Δ cr g H m o ( ), Δ l g H m o ( ) and Δ cr l H m o (T fus ) values, as well as the heat capacity differences between gas and liquid and the heat capacity differences between gas and solid, Δ l g C p,m o and Δ cr g C p,m o , respectively, both estimated by applying a group additivity procedure. Therefore, the averages of the standard (p o = 0.1 MPa) molar enthalpies, entropies and Gibbs energies of sublimation at 298.15 K, have been derived.

  18. Dental lesions and restorative treatment in molars

    Directory of Open Access Journals (Sweden)

    Gheorghiu Irina-Maria

    2017-08-01

    Full Text Available This article review specific clinical issues of the molar teeth, as well as the therapeutic approach of their pathology. The dental pathology we face in the group of molars is related to: dental caries, dental trauma (crown and crown-root fractures, dental wear phenomena. The therapeutic approach of the molar teeth is represented by: restoration of the loss of hard dental tissues; endodontic treatments of pulpal and periapical complications; surgical treatment. The restorative treatments in molars are: direct restorations, with or without supplementary anchorage for obturations; inlay, onlay; prosthetic crown.

  19. Application of some geometrical and empirical models to excess molar volume for the multi-component mixtures at T = 298.15 K

    International Nuclear Information System (INIS)

    Iloukhani, H.; Khanlarzadeh, K.

    2012-01-01

    Highlights: ► Excess molar volume of quartenary mixtures of 1-chlorobutane, 2-chlorobutane, butylamine, and butylacetate was determined. ► The experimental data were correlated by some empirical and semi empirical models. ► A comparison with PFP theory has been successfully applied from binary data. - Abstract: Densities of the quaternary mixture consisting of {1-chlorobutane (1) + 2-chlorobutane (2) + butylamine (3) + butylacetate (4)} and related ternary mixtures of {1-chlorobutane (1) + 2-chlorobutane (2) + butylamine (3)}, {1-chlorobutane (1) + 2-chlorobutane (2) + butylacetate (4)}, {2-chlorobutane (2) + butylamine (3) + butylacetate (4)}, and binary systems of {1-chlorobutane (1) + 2-chlorobutane (2)}, {2-chlorobutane (2) + butylamine (3)}, were measured over the whole range of composition at T = 298.15 K and ambient pressure. Excess molar volumes, V m E , for the mixtures were derived and correlated as a function of mole fraction by using the Redlich–Kister and the Cibulka equations for binary and ternary mixtures, respectively. From the experimental data, partial molar volumes, V m,i and excess partial molar volumes, V m,i E were also calculated for binary systems. The experimental results of the constituted binary mixtures have been used to test the applicability of the Prigogine–Flory–Paterson (PFP) theory. A number of geometrical and empirical equations were also used to verify their ability to predict ternary and quaternary properties from their lower order mixtures. The experimental data were used to evaluate the nature and type of intermolecular interactions in multi-component mixtures.

  20. Autogenous transplantation of maxillary and mandibular molars.

    Science.gov (United States)

    Reich, Peter P

    2008-11-01

    Autogenous tooth transplantation has been used as a predictable surgical approach to correct malocclusion and replace edentulous areas. This article focuses on the surgical approach and technique for molar transplantation. Thirty-two patients aged between 11 and 25 years underwent 44 autogenous molar transplantations. The procedure involved transplantation of impacted or newly erupted third molars into the extraction sockets of nonrestorable molars and surgical removal and replacement of horizontally impacted molars into their proper vertical alignment. Five basic procedural concepts were applied: 1) atraumatic extraction, avoiding disruption of the root sheath and root buds; 2) apical contouring of bone at the transplantation site and maxillary sinus lift via the Summers osteotome technique, when indicated, for maxillary molars; 3) preparation of a 4-wall bony socket; 4) avoidance of premature occlusal interferences; and 5) stabilization of the tooth with placement of a basket suture. All 32 patients successfully underwent the planned procedure. To date, 2 patients have had localized infection that resulted in loss of the transplant. The remaining 42 transplants remain asymptomatic and functioning, with a mean follow-up period of 19 months. No infection, ankylosis, loss of the transplant, or root resorption has been noted. In addition, endodontic therapy has not been necessary on any transplanted teeth. Autogenous tooth transplantation has been discussed and described in the literature previously, with a primary focus on cuspid and bicuspid transplantation. The molar transplant is infrequently discussed in today's literature, possibly because of the preponderance of titanium dental implants. Autogenous molar transplantation is a viable procedure with low morbidity and excellent functional and esthetic outcomes. This report shows the successful transplantation of 42 of 44 molars in 32 patients with a mean follow-up period of 19 months.

  1. Does fixed retention prevent overeruption of unopposed mandibular second molars in maxillary first molar extraction cases?

    NARCIS (Netherlands)

    Livas, Christos; Halazonetis, Demetrios J; Booij, Johan W; Katsaros, Christos; Ren, Yijin

    2016-01-01

    BACKGROUND: The objective of this study was to investigate whether multistranded fixed retainers prevented overeruption of unopposed mandibular second molars in maxillary first molar extraction cases. METHODS: The panoramic radiographs of 65 Class II Division 1 Caucasian Whites (28 females, 37

  2. Maxillary molar distalization with first class appliance.

    Science.gov (United States)

    Ramesh, Namitha; Palukunnu, Biswas; Ravindran, Nidhi; Nair, Preeti P

    2014-02-27

    Non-extraction treatment has gained popularity for corrections of mild-to-moderate class II malocclusion over the past few decades. The distalization of maxillary molars is of significant value for treatment of cases with minimal arch discrepancy and mild class II molar relation associated with a normal mandibular arch and acceptable profile. This paper describes our experience with a 16-year-old female patient who reported with irregularly placed upper front teeth and unpleasant smile. The patient was diagnosed to have angles class II malocclusion with moderate maxillary anterior crowding, deep bite of 4 mm on a skeletal class II base with an orthognathic maxilla and retrognathic mandible and normal growth pattern. She presented an ideal profile and so molar distalization was planned with the first-class appliance. Molars were distalised by 8 mm on the right and left quadrants and class I molar relation achieved within 4 months. The space gained was utilised effectively to align the arch and establish a class I molar and canine relation.

  3. Characteristics of hydrogen produced by partial oxidation and auto-thermal reforming in a small methanol reformer

    Science.gov (United States)

    Horng, Rong-Fang; Chou, Huann-Ming; Lee, Chiou-Hwang; Tsai, Hsien-Te

    This paper investigates experimentally, the transient characteristics of a small methanol reformer using partial oxidation (POX) and auto-thermal reforming (ATR) for fuel cell applications. The parameters varied were heating temperature, methanol supply rate, steady mode shifting temperature, O 2/C (O 2/CH 3OH) and S/C (H 2O/CH 3OH) molar ratios with the main aim of promoting a rapid response and a high flow rate of hydrogen. The experiments showed that a high steady mode shifting temperature resulted in a faster temperature rise at the catalyst outlet and vice versa and that a low steady mode shifting temperature resulted in a lower final hydrogen concentration. However, when the mode shifting temperature was too high, the hydrogen production response was not necessarily improved. It was subsequently shown that the optimum steady mode shifting temperature for this experimental set-up was approximately 75 °C. Further, the hydrogen concentration produced by the auto-thermal process was as high as 49.12% and the volume flow rate up to 23.0 L min -1 compared to 40.0% and 20.5 L min -1 produced by partial oxidation.

  4. Magnetic Heat Pump Containing Flow Diverters

    Science.gov (United States)

    Howard, Frank S.

    1995-01-01

    Proposed magnetic heat pump contains flow diverters for suppression of undesired flows. If left unchecked, undesired flows mix substantial amounts of partially heated and partially cooled portions of working fluid, effectively causing leakage of heat from heated side to cooled side. By reducing leakage of heat, flow diverters increase energy efficiency of magnetic heat pump, potentially offering efficiency greater than compressor-driven refrigerator.

  5. Calculation of partial enthalpies in argon-krypton mixtures by NPT molecular dynamics

    NARCIS (Netherlands)

    Sindzingre, P.; Massobrio, C.; Ciccotti, G.; Frenkel, D.

    1989-01-01

    In an earlier paper, we have indicated how, by using a particle-insertion technique, partial molar enthalpies and related quantities can be evaluated from simulations on a single state point. In the present paper we apply this method to a Lennard-Jones argon-krypton mixture. For this particular

  6. Thermodynamics of the interactions of some amino acids and peptides with dodecyltrimethylammonium bromide and tetradecyltrimethylammonium bromide

    International Nuclear Information System (INIS)

    Talele, Paurnima; Kishore, Nand

    2014-01-01

    Highlights: • Interactions of amino acids and peptides were studied with two cationic surfactants. • Partial molar properties and hydration numbers did not change significantly. • Measured properties indicate balance of polar and non-polar interactions. • Peptide bonds did not strengthen the extent of polar interactions with surfactant. • Results provide quantitative fine details of cationic surfactant–amino acids/peptides interactions. -- Abstract: The values of apparent molar volume V 2,ϕ and apparent molar adiabatic compressibility K S,2,ϕ of amino acids glycine, L-alanine, DL-α-amino-n-butyric acid, L-valine, L-leucine and peptides glycyl-glycine, glycyl-glycyl-glycine and glycyl-leucine have been determined in aqueous solutions of cationic surfactants dodecyltrimethylammonium bromide (DTAB) and tetradecyltrimethylammonium bromide (TTAB) by means of density and sound velocity measurements. The heat evolved or absorbed (q) during the course of interactions of amino acids and peptides with the aqueous solutions of surfactants were determined by isothermal titration calorimetry at T = 298.15 K. The values of standard partial molar volume V 2,m 0 and standard partial molar adiabatic compressibility K s,2,m 0 at infinite dilution were calculated from the values of V 2,ϕ and K S,2,ϕ . Similarly the values of limiting enthalpies of dilution (Δ dil H 0 ) of the amino acids/peptides were calculated from heat evolved or absorbed during calorimetric experiments. The standard partial molar quantities of transfer from water to aqueous surfactant solutions have been used to identify the interactions of amino acids and peptides with surfactants in terms of ionic–ionic, ionic–hydrophobic and hydrophobic–hydrophobic group interactions

  7. Dimensional analysis to transform the differential equations in partial derivates in the theory of heat transmission into ordinary ones

    International Nuclear Information System (INIS)

    Diaz Sanchidrian, C.

    1989-01-01

    The present paper applies dimensional analysis with spatial discrimination to transform the differential equations in partial derivatives developed in the theory of heat transmission into ordinary ones. The effectivity of the method is comparable to that methods based in transformations of uni or multiparametric groups, with the advantage of being more direct and simple. (Author)

  8. Association between Peritonsillar Abscess and Molar Caries

    Directory of Open Access Journals (Sweden)

    M Shayani Nasab

    2006-05-01

    Full Text Available Background: Peritonsillar abscess is the most common deep neck infections that are related with periodontal disease which has the same pathogenesis. We determined the relationship between peritonsillar infection and molar caries. Methods: In a cross-sectional study, 33 consecutive patients whom referred to Hamadan university clinic of otolaryngologic for peritonsillar abscess were examined by otolaryngologist and dentist who investigated relationship between peritonsillar infection and molar caries. Results: There were 27 males and 6 females with mean age 26.7+_7 years. The frequency caries on ipsilateral peritonsillar infection sides was in relation to molars caries on opposite sides (conterol group. This corrolation was significant with odds ratio 2.5. Conclusion: Molar caries were seen 2.5 times more likely to have peritonsillar infection compared with normal molar sides. Key Words: Peritonsillar abscess, Infection, Periodontal disease, Dental caries

  9. Apparent molar volumes and compressibilities of lanthanum, gadolinium, lutetium and sodium trifluoromethanesulfonates in N,N-dimethylformamide and N,N-dimethylacetamide

    International Nuclear Information System (INIS)

    Warmińska, Dorota; Fuchs, Anna; Lundberg, Daniel

    2013-01-01

    Highlights: ► In DMF the sequence values of both volumes and compressibilities of Ln 3+ ions are: La 3+ ≈ Gd 3+ > Lu 3+ . ► In DMA the ionic volumes of lanthanoid(III) metal ions are, within error limits, identical. ► Obtained results are the consequence of an ion–solvent bonding nature. -- Abstract: The concentration and temperature dependencies of density of lanthanum, gadolinium, lutetium and sodium trifluoromethanesulfonates in N,N-dimethylformamide (DMF) and N,N-dimethylacetamide (DMA) have been determined. From density data the apparent molar volumes and partial molar volumes of the salts at infinite dilution as well as the expansibilities have been evaluated. The apparent molar isentropic compressibilities of lanthanum, gadolinium, lutetium and sodium trifluoromethanesulfonates in DMF and DMA have been calculated from sound velocity data obtained at 298.15 K. The results have been discussed in terms of ion–solvent interactions

  10. Recurrent hydatidiform mole: A case report of six consecutive molar pregnancies complicated by choriocarcinoma, and review of the literature

    Directory of Open Access Journals (Sweden)

    Ahlam A Al-Ghamdi

    2011-01-01

    Full Text Available Hydatidiform mole (HM is the most common form of gestational trophoblastic neoplasia. Recurrence of HM is extremely rare. Here, we report the case of a patient with six consecutive partial HMs without normal pregnancy. A 42-year-old lady who was referred to us at King Fahad Hospital of the University, Al Khobar, initially as a case of 26-year-old with persistent trophoblastic disease after three recurrent molar pregnancies that were confirmed histologically in the referring hospital. She underwent evacuation and curettage and was followed up by serial β-human chorionic gonadotropin levels, and did not require chemotherapy. She then had three more molar pregnancies in 1995, 1996, and 2004; all molar pregnancies were evacuated by suction curettage at her base hospital, but in the last event, she complained of shortness of breath and abdominal pain. Diagnostic workup in our hospital confirmed choriocarcinoma, for which she received multiple regimen chemotherapy and was cured. Unfortunately, she lately presented with symptoms suggestive of premature menopause.

  11. Radiologic study of mandibular third molar of Korean youths

    International Nuclear Information System (INIS)

    Ahn, Hyung Kyu

    1982-01-01

    The author has made a study on the classification of the mandibular 3rd molars of Korean youths through dental radiography by means of Pell and Gregory's classification and on the prevalence of the dental caries of distal surface of the mandibular 2nd molar adjacent to the mandibular 3rd molars turned anteriorly. The results are as follow; 1. It was found that the largest case number was class I (272 cases, 52.9%) in the relation of the tooth to the ramus of the mandible and 2nd molar. 2. The mesio-angular position was the largest number (239 cases, 46.5%) in the relation of the long axis of the impacted mandibular 3rd molar to the long axis of the 2nd molar. 3. The mesio-angular position of class I was the largest number (140 cases, 27.2%) in the relation of the tooth to the ramus of the mandible and 2nd molar and the long axis of the impacted mandibular 3rd moral to the long axis of the 2nd molar. 4. The average angle of the long axis of mandibular 3rd molar in mesioangular position or horizontal position to the occlusal plane was 143 W 5. Mandibular 3rd molar with lesion such as dental cries or pericoronitis was 73 cases (14.2). 6. The caries incidence rate of the distal surface of the 2nd molar was about 3.1%.

  12. Third molar development: measurements versus scores as age predictor.

    Science.gov (United States)

    Thevissen, P W; Fieuws, S; Willems, G

    2011-10-01

    Human third molar development is widely used to predict chronological age of sub adult individuals with unknown or doubted age. For these predictions, classically, the radiologically observed third molar growth and maturation is registered using a staging and related scoring technique. Measures of lengths and widths of the developing wisdom tooth and its adjacent second molar can be considered as an alternative registration. The aim of this study was to verify relations between mandibular third molar developmental stages or measurements of mandibular second molar and third molars and age. Age related performance of stages and measurements were compared to assess if measurements added information to age predictions from third molar formation stage. The sample was 340 orthopantomograms (170 females, 170 males) of individuals homogenously distributed in age between 7 and 24 years. Mandibular lower right, third and second molars, were staged following Gleiser and Hunt, length and width measurements were registered, and various ratios of these measurements were calculated. Univariable regression models with age as response and third molar stage, measurements and ratios of second and third molars as predictors, were considered. Multivariable regression models assessed if measurements or ratios added information to age prediction from third molar stage. Coefficients of determination (R(2)) and root mean squared errors (RMSE) obtained from all regression models were compared. The univariable regression model using stages as predictor yielded most accurate age predictions (males: R(2) 0.85, RMSE between 0.85 and 1.22 year; females: R(2) 0.77, RMSE between 1.19 and 2.11 year) compared to all models including measurements and ratios. The multivariable regression models indicated that measurements and ratios added no clinical relevant information to the age prediction from third molar stage. Ratios and measurements of second and third molars are less accurate age predictors

  13. Bilateral maxillary fused second and third molars: a rare occurrence.

    Science.gov (United States)

    Liang, Rui-Zhen; Wu, Jin-Tao; Wu, You-Nong; Smales, Roger J; Hu, Ming; Yu, Jin-Hua; Zhang, Guang-Dong

    2012-12-01

    This case report describes the diagnosis and endodontic therapy of maxillary fused second and third molars, using cone-beam computed tomography (CBCT). A 31-year-old Chinese male, with no contributory medical or family/social history, presented with throbbing pain in the maxillary right molar area following an unsuccessful attempted tooth extraction. Clinical examination revealed what appeared initially to be a damaged large extra cusp on the buccal aspect of the distobuccal cusp of the second molar. However, CBCT revealed that a third molar was fused to the second molar. Unexpectedly, the maxillary left third molar also was fused to the second molar, and the crown of an unerupted supernumerary fourth molar was possibly also fused to the apical root region of the second molar. Operative procedures should not be attempted without adequate radiographic investigation. CBCT allowed the precise location of the root canals of the right maxillary fused molar teeth to permit successful endodontic therapy, confirmed after 6 months.

  14. Autotransplantation of Mandibular Third Molar: A Case Report

    Directory of Open Access Journals (Sweden)

    Pabbati Ravi kumar

    2012-01-01

    Full Text Available Autogenous transplantation is a feasible, fast, and economical option for the treatment of nonsalvageable teeth when a suitable donor tooth is available. This paper presents successful autotransplantation of a mature mandibular left third molar (38 without anatomical variances is used to replace a mandibular left second molar (37. The mandibular second molar was nonrestorable due to extensive root caries and resorption of distal root. After extraction of mandibular second and third molars, root canal therapy was done for the third molar extraorally, and the tooth was reimplanted into the extracted socket of second molar site. After one year, clinical and radiographic examination revealed satisfactory outcome with no signs or symptoms suggestive of pathology. In selected cases, autogenous tooth transplantation, even after complete root formation of the donor tooth, may be considered as a practical treatment alternative to conventional prosthetic rehabilitation or implant treatment.

  15. Survival of sealants in molars affected by molar-incisor hypomineralization: 18-month follow-up

    Directory of Open Access Journals (Sweden)

    Camila Maria Bullio FRAGELLI

    2017-04-01

    Full Text Available Abstract The objective of this study was to evaluate the clinical survival of sealants applied in first permanent molars (FPMs affected by molar-incisor hypomineralization (MIH, at 18 months of follow-up. Forty-one first permanent molars were selected from 21 children, 6–8 years of age. MIH was classified by one calibrated examiner (kappa = 0.80 according to EAPD criteria. The inclusion criteria were fully erupted FPMs with MIH or sound FPMs (without MIH for which sealant treatment was indicated. The FPMs were assigned to two groups: CG (control group and HG (MIH group. Both groups were treated with sealant (FluroShield. Clinical follow-up was performed from baseline to 18 months to assess anatomical form, marginal adaptation, retention and presence of caries, according to criteria set by the United States Public Health Service-Modified, and was conducted by a blinded examiner (kappa = 0.80. The actuarial method was used to evaluate the survival of the sealants. The survival rates for the groups were compared using Fisher’s exact test (α = 5%. The cumulative survival rates were 81% at 1 month, 68.8% at 6 months, 68.8% at 12 months, and 62.6% at 18 months for CG, and 88% at 1 month, 84% at 6 months, 76% at 12 months, and 72% at 18 months for HG. No significant difference was found between the groups. The sealants in molars affected by MIH presented a survival rate similar to the sealants in the control, suggesting that sealants may be an adequate approach for preventing carious lesions in MIH-affected molars.

  16. Intrapulpal Temperature Rise During Light Activation of Restorative Composites in a Primary Molar.

    Science.gov (United States)

    Vinall, Craig V; Garcia-Silva, Tales C; Lou, Jennifer S B; Wells, Martha H; Tantbirojn, Daranee; Versluis, Antheunis

    2017-05-15

    To investigate intrapulpal temperature rise in a primary molar during light activation of a composite restoration to determine if clinically significant pulpal temperatures (greater than 5.5 degrees Celsius) were reached. Restorative composites (EsthetX HD, Filtek Supreme Ultra, Filtek Bulk Fill) were placed into a primary molar with occlusal preparation (1.5 mm depth; remaining pulpal floor thickness one mm). The pulp was extirpated through a root access to place a thermocouple against the pulpal roof. Temperature changes were recorded during composite restoration light polymerization with three curing lights (one quartz-tungsten-halogen, two LEDs). Sample size was 10. Samples received additional irradiation to assure complete polymerization, followed by a third irradiation for calculating the exothermic heat contribution (subtracting third irradiation temperatures from first irradiation temperatures). Cured restorations were removed after each test, and the tooth was reused. Results were analyzed with Kruskal-Wallis (α =0.05). Type of curing light and composite material affected the intrapulpal temperature rise, which was up to five degrees Celsius for one combination of LED-composite. Clinicians should be aware of the potential for clinically significant intrapulpal temperature rises when light-activating composite restorations in a primary molar with a moderately deep cavity.

  17. Managing molar-incisor hypomineralization: A systematic review.

    Science.gov (United States)

    Elhennawy, Karim; Schwendicke, Falk

    2016-12-01

    We systematically reviewed treatment modalities for MIH-affected molars and incisors. Trials on humans with ≥1 MIH molar/incisor reporting on various treatments were included. Two authors independently searched and extracted records. Sample-size-weighted annual failure rates were estimated where appropriate. The risk of bias was assessed using the Newcastle-Ottawa scale. Electronic databases (PubMed, Embase, Cochrane CENTRAL, Google Scholar) were screened, and hand searches and cross-referencing performed. Fourteen (mainly observational) studies were included. Ten trials (381 participants) investigated MIH-molars, four (139) MIH-incisors. For molars, remineralization, restorative or extraction therapies had been assessed. For restorative approaches, mean (SD) annual failure rates were highest for fissure sealants (12[6]%) and glass-ionomer restorations (12[2]%), and lowest for indirect restorations (1[3]%), preformed metal crowns (1.3 [2.1]%) and composite restorations (4[3]%). Ony study assessed extraction of molars in young patients (median age 8.2 years), the majority of them without malocclusions, but third molars in development. Spontaneous alignment of second molars was more frequent in the maxilla (55%) than the mandible (47%). For incisors, desensitizing agents successfully managed hypersensitivity. Micro-abrasion and composite veneers improved aesthetics. Few, mainly moderate to high-risk-studies investigated treatment of MIH. Remineralization or sealants seem suitable for MIH-molars with limited severity and/or hypersensitivity. For severe cases, restorations with composites or indirect restorations or preformed metal crowns seem suitable. Prior to tooth extraction as last resort factors like the presence of a general malocclusion, patients' age and the status of neighboring teeth should be considered. No recommendations can be given for MIH-incisors. Dentists need to consider the specific condition of each tooth and the needs and expectations of

  18. A Structural Molar Volume Model for Oxide Melts Part III: Fe Oxide-Containing Melts

    Science.gov (United States)

    Thibodeau, Eric; Gheribi, Aimen E.; Jung, In-Ho

    2016-04-01

    As part III of this series, the model is extended to iron oxide-containing melts. All available experimental data in the FeO-Fe2O3-Na2O-K2O-MgO-CaO-MnO-Al2O3-SiO2 system were critically evaluated based on the experimental condition. The variations of FeO and Fe2O3 in the melts were taken into account by using FactSage to calculate the Fe2+/Fe3+ distribution. The molar volume model with unary and binary model parameters can be used to predict the molar volume of the molten oxide of the Li2O-Na2O-K2O-MgO-CaO-MnO-PbO-FeO-Fe2O3-Al2O3-SiO2 system in the entire range of compositions, temperatures, and oxygen partial pressures from Fe saturation to 1 atm pressure.

  19. Standard molar Gibbs free energy of formation of URh3(s)

    International Nuclear Information System (INIS)

    Prasad, Rajendra; Sayi, Y.S.; Radhakrishna, J.; Yadav, C.S.; Shankaran, P.S.; Chhapru, G.C.

    1992-01-01

    Equilibrium partial pressures of CO(g) over the system (UO 2 (s) + C(s) + Rh(s) + URh 3 (s)) were measured in the temperature range 1327 - 1438 K. Standard Gibbs molar free energy of formation of URh 3 (Δ f G o m ) in the above temperature range can be expressed as Δ f G o m (URh 3 ,s,T)+-3.0(kJ/mol)= -348.165 + 0.03144 T(K). The second and third law enthalpy of formation, ΔfH o m (URh 3 ,s,298.15 K) are (-318.4 +- 3.0) and (298.3 +- 2.5) kJ/mol respectively. (author). 7 refs., 3 tabs

  20. Taking advantage of an unerupted third molar: a case report

    Directory of Open Access Journals (Sweden)

    Igor Figueiredo Pereira

    Full Text Available ABSTRACT Introduction: Treatments with dental surgery seek to displace tooth to the correct position within the dental arch. Objective: To report a clinical case that took advantage of an unerupted third molar. Case history: A male patient, 18 years of age, was referred by his dentist to evaluate the third molars. The clinical exam revealed no visible lower third molars. The computed tomography (CT exam showed the presence of a supernumerary tooth in the region of the mandibular ramus, on the left side, and impaction of the third molar, which was causing root resorption on the second molar, thus making it impossible to remain in the buccal cavity. The preferred option, therefore, was to remove both second molar and the supernumerary tooth, in addition to attaching a device to the third molar during surgery for further traction. Results: After 12 months, the third molar reached the proper position. Conclusion: When a mandibular second permanent molar shows an atypical root resorption, an impacted third molar can effectively substitute the tooth by using an appropriate orthodontic-surgical approach.

  1. Prevalence of cheese molars in eleven-year-old Dutch children.

    Science.gov (United States)

    Weerheijm, K L; Groen, H J; Beentjes, V E; Poorterman, J H

    2001-01-01

    In the Netherlands, first permanent molars with idiopathic enamel disturbances (IED) are called cheese molars. Though concern is expressed about their prevalence, adequate figures on the subject are missing. The porous enamel of cheese molars can be very sensitive to cold air and can decay rapidly. The aim of the present study was to investigate the prevalence in eleven-year-old Dutch children of cheese molars (IED). During an epidemiological study performed in four cities in the Netherlands, the first permanent molars and central incisors of eleven-year-old children were examined for hypoplasia, opacities, posteruptive enamel loss, premature extraction, and atypical restorations. The observation of a hypoplasia excluded the possibility of cheese molar. A total of 497 children were examined. Six percent (n = 128) of the molars (n = 1988) showed signs of IED (cheese molars), 10 percent of the children had cheese molars of which 8 percent two or more. Incisors (4 percent) with opacities were found in 3 percent in combination with two or more cheese molars. Among the four cities, no significant differences in occurrence were found. The results of this study showed that in 10 percent of the Dutch children eleven years of age, cheese molars (IED) were found. The cause for the phenomenon called cheese molars appears to be child centered. Further studies on prevalence, causes and prevention are mandatory.

  2. External and internal anatomy of third molars.

    Science.gov (United States)

    Guerisoli, D M; de Souza, R A; de Sousa Neto, M D; Silva, R G; Pécora, J D

    1998-01-01

    The external and internal anatomy of 269 third molars (155 maxillary and 114 mandibular) were studied. The teeth were measured, classified according to their root number and shape and the internal anatomy was observed by the use of diaphanization. A great anatomical variability was found, with the presence of up to 5 roots in maxillary third molars and 3 roots in mandibular third molars. The number of root canals followed the same pattern.

  3. Numerical investigation of double diffusive buoyancy forces induced natural convection in a cavity partially heated and cooled from sidewalls

    Directory of Open Access Journals (Sweden)

    Rasoul Nikbakhti

    2016-03-01

    Full Text Available This paper deals with a numerical investigation of double-diffusive natural convective heat and mass transfer in a cavity filled with Newtonian fluid. The active parts of two vertical walls of the cavity are maintained at fixed but different temperatures and concentrations, while the other two walls, as well as inactive areas of the sidewalls, are considered to be adiabatic and impermeable to mass transfer. The length of the thermally active part equals half of the height. The non-dimensional forms of governing transport equations that describe double-diffusive natural convection for two-dimensional incompressible flow are functions of temperature or energy, concentration, vorticity, and stream-function. The coupled differential equations are discretized via FDM (Finite Difference Method. The Successive-Over-Relaxation (SOR method is used in the solution of the stream function equation. The analysis has been done for an enclosure with different aspect ratios ranging from 0.5 to 11 for three different combinations of partially active sections. The results are presented graphically in terms of streamlines, isotherms and isoconcentrations. In addition, the heat and mass transfer rate in the cavity is measured in terms of the average Nusselt and Sherwood numbers for various parameters including thermal Grashof number, Lewis number, buoyancy ratio and aspect ratio. It is revealed that the placement order of partially thermally active walls and the buoyancy ratio influence significantly the flow pattern and the corresponding heat and mass transfer performance in the cavity.

  4. Partial molar volumes of organic solutes in water. XXVI. 15-Crown-5 and 18-crown-6 ethers at temperatures (298 to 573) K and pressures up to 30 MPa

    International Nuclear Information System (INIS)

    Cibulka, Ivan

    2015-01-01

    Highlights: • Density data were obtained in the range T from (298 to 573) K and p up to 30 MPa. • Standard molar volumes of two crown ethers in water are presented. • Group contribution method was designed to estimate standard molar volumes of cyclic ethers. - Abstract: Densities of dilute aqueous solutions of two cyclic ethers, viz. 15-crown-5 and 18-crown-6, measured over the temperature range from (298 to 573) K and at pressures up to 30 MPa using an automated flow vibrating-tube densimeter are reported. Standard molar volumes were evaluated from the measured data. Present data were combined with those obtained previously for several cyclic ethers and predictions of standard molar volumes based on group contribution approach were tested and analysed

  5. Prediction of postoperative pain after mandibular third molar surgery

    DEFF Research Database (Denmark)

    Rudin, Asa; Eriksson, Lars; Liedholm, Rolf

    2010-01-01

    . Standardized surgery was performed during local anesthesia. Postoperative pain management was with rescue paracetamol and ibuprofen. The patients were instructed to record each day their pain at rest and during dynamic conditions, and their requirement of analgesics for 14 days following surgery.......To evaluate the predictive potential of preoperative psychological and psychophysiological variables in estimating severity of postoperative pain following mandibular third molar surgery (MTMS). Methods: Following ethical committee approval and informed consent, 40 consecutive patients scheduled...... for MTMS were included. Preoperative psychometric indicators of anxiety, depression, and vulnerability were evaluated by patient questionnaires. Thermal thresholds and heat pain perception (1 second phasic stimuli: 44 degrees C to 48 degrees C) were evaluated with quantitative sensory testing techniques...

  6. Image analysis of the eruptive positions of third molars and adjacent second molars as indicators of age evaluation in Thai patients.

    Science.gov (United States)

    Mahasantipiya, Phattaranant May; Pramojanee, Sakarat; Thaiupathump, Trasapong

    2013-12-01

    This study was performed to determine the relationship between the stage of tooth eruption (both vertical and mesio-angular) and chronological age. Indirect digital panoramic radiographs were used to measure the distances from the dentinoenamel junction (DEJ) of the second molars to the occlusal plane of the second molar teeth and of the adjacent third molars in 264 Thai males and 437 Thai females using ImageJ software. The ratio of those distances was calculated by patient age, and the correlation coefficient of the ratio of the third molar length to the second molar length was calculated. The correlation between the height of the vertically erupted upper third molar teeth and age was at the intermediate level. The age range of ≥15 to age determined from the eruptional height and actual chronological age was statistically significant. The mean age of the female subjects, in which the position of the right upper third molar teeth was at or above the DEJ of the adjacent second molar but below one half of its coronal height was 19.9±2.6 years. That for the left side was 20.2±2.7 years. The mean ages of the male subjects were 20.1±3.3 years and 19.8±2.7 years for the right and left sides, respectively. It might be possible to predict chronological age from the eruption height of the wisdom teeth.

  7. [Orthodontic Management of the Impacted Mandibular Second Molar Tooth].

    Science.gov (United States)

    Mah, Michael; Takada, Kenji

    2016-09-01

    When the mandibular permanent second molar becomes impacted, it is identified as a malocclusion that needs treatment as it often leads to unwanted complications such as caries and periodontitis of the adjacent permanent first molar. Other less common complications include root resorption of the adjacent first molar root or continued root development to be in close proximity to the inferior dental alveolar nerve. This paper seeks to differentiate various levels of severity of impaction and review treatment options that are considered clinically available for the proper management of the impacted mandibular permanent second molar. Treatment options that will be discussed in this article include timing of second molar removal for replacement by the third molar, relief of impaction via second premolar removal, surgical repositioning and the combination of third molar removal, surgical exposure and orthodontic uprighting of the impacted tooth. Depending on the severity of the impaction, most impactions can be easily and predictably corrected with nickel titanium archwires or auxillary open coil springs or uprighting springs. Uncommonly, the mandibular permanent second molar can become severely impacted and in close proximity to the inferior dentoalveolar nerve. In these instances, the use of temporary anchorage devices such as microimplants has shown to be successful in uprighting the severely impacted mandibular permanent second molars. © EDP Sciences, SFODF, 2016.

  8. Epidemiological Status of Third Molars in an Iranian Population

    Directory of Open Access Journals (Sweden)

    Mahnaz Sheikhi

    2016-07-01

    Full Text Available Background Impaction of third molars is a common phenomenon. The incidence of impacted third molars varies in different populations. Objectives The aim of this study is to assess radiographic status (root development degree, angulation, and eruption level of the third molar in Iranian population via panoramic radiographs. Patients and Methods 647 patients, ranging in age from 17 - 25, were selected from three regions of Iran. Based on their panoramic radiographs, their root development degree, angulation, and eruption levels were analyzed. Results The angulation of upper third molars were vertical (44.6%, distoangular (44.1%, mesioangular (10.7%, and horizontal (0.6%. For lower third molars, the angulation was mesioangular (44.5%, vertical (33.8%, distoangular (12.2%, and horizontal (9.5%. The eruption levels of maxillary third molars were C > A> B, and for mandibular third molars they were A > B> C. The order of root development prevalence of the maxillary and mandibular third molars was complete > 2/3 > 1/3. Conclusions The most common status of impaction of the third molars in the maxilla was vertical angulation, level C of eruption, and complete root formation. In the mandible it was mesioangular, level A of eruption, and complete root formation. Since the study sample consists of patients from the north, middle, and south of Iran, the sample can represent the whole population of Iran.

  9. Root growth during molar eruption in extant great apes.

    Science.gov (United States)

    Kelley, Jay; Dean, Christopher; Ross, Sasha

    2009-01-01

    While there is gradually accumulating knowledge about molar crown formation and the timing of molar eruption in extant great apes, very little is known about root formation during the eruption process. We measured mandibular first and second molar root lengths in extant great ape osteological specimens that died while either the first or second molars were in the process of erupting. For most specimens, teeth were removed so that root lengths could be measured directly. When this was not possible, roots were measured radiographically. We were particularly interested in the variation in the lengths of first molar roots near the point of gingival emergence, so specimens were divided into early, middle and late phases of eruption based on the number of cusps that showed protein staining, with one or two cusps stained equated with immediate post-gingival emergence. For first molars at this stage, Gorilla has the longest roots, followed by Pongo and Pan. Variation in first molar mesial root lengths at this stage in Gorilla and Pan, which comprise the largest samples, is relatively low and represents no more than a few months of growth in both taxa. Knowledge of root length at first molar emergence permits an assessment of the contribution of root growth toward differences between great apes and humans in the age at first molar emergence. Root growth makes up a greater percentage of the time between birth and first molar emergence in humans than it does in any of the great apes. Copyright (c) 2009 S. Karger AG, Basel.

  10. One year Survival Rate of Ketac Molar versus Vitro Molar for Occlusoproximal ART Restorations: a RCT

    Directory of Open Access Journals (Sweden)

    PACHECO Anna Luisa de Brito

    2017-11-01

    Full Text Available Abstract Good survival rates for single-surface Atraumatic Restorative Treatment (ART restorations have been reported, while multi-surface ART restorations have not shown similar results. The aim of this study was to evaluate the survival rate of occluso-proximal ART restorations using two different filling materials: Ketac Molar EasyMix (3M ESPE and Vitro Molar (DFL. A total of 117 primary molars with occluso-proximal caries lesions were selected in 4 to 8 years old children in Barueri city, Brazil. Only one tooth was selected per child. The subjetcs were randomly allocated in two groups according to the filling material. All treatments were performed following the ART premises and all restorations were evaluated after 2, 6 and 12 months. Restoration survival was evaluated using Kaplan-Meier survival analysis and Log-rank test, while Cox regression analysis was used for testing association with clinical factors (α = 5%. There was no difference in survival rate between the materials tested, (HR = 1.60, CI = 0.98–2.62, p = 0.058. The overall survival rate of restorations was 42.74% and the survival rate per group was Ketac Molar = 50,8% and Vitro Molar G2 = 34.5%. Cox regression test showed no association between the analyzed clinical variables and the success of the restorations. After 12 months evaluation, no difference in the survival rate of ART occluso-proximal restorations was found between tested materials.

  11. Mandibular molar crown-topography, a biological predisposing ...

    African Journals Online (AJOL)

    Mandibular molar crown-topography, a biological predisposing factor to development of caries – a post-mortem analysis of 2500 extracted lower permanent molars at the dental centre, University of Benin teaching hospital.

  12. Morphometric evaluation of external root resorption of mandibular second molar teeth adjacent to the impacted third molars in CBCT imaging of Tehran\\'s population between 2011-2014

    Directory of Open Access Journals (Sweden)

    Fatemeh Ezoddini Ardakani

    2017-04-01

    Full Text Available Introduction: Presence of external root resorption in second molars associated with impacted mandibular third molars was not rare. The neglect of this issue may leads to penetration of the pulp and loss of the second molars. The aim of this study was to investigate the incidence and risk factors affecting the external root resorption in second molars associated with mandibular impacted third molars were inclined mesially and horizontally by Cone Beam Computer Tomography (CBCT images. Methods: In this cross sectional study the samples consisted of 231 scans with mesially and horizontally impacted mandibular third molars. Incidence of external root resorption of second molars and the effects of age, gender and clinical parameters such as location and intensity of external root resorption were considered. Moreover, depth and inclination of impacted mandibular third molar were evaluated by CBCT. The data were analyzed by Chi-square test. Results: The overall incidence of external root resorption in the second molars was 22.08%. Incidence of external root resorption in second molars was significantly related to gender and inclination of third molar. The relations between external root resorption and impaction depth of third molar or the patient's age was not statistically significant. However, the relationship between external root resorption and the intensity or depth of impacted third molar and location of root resorption was statistically meaningful. Conclusion: Patient’s gender and horizontal inclination of third molars are the most important factors affecting the presence of external root resorption in the second molars associated with mesially and horizontally impacted mandibular third molars.

  13. Volumetric and calorimetric properties of aqueous ionene solutions.

    Science.gov (United States)

    Lukšič, Miha; Hribar-Lee, Barbara

    2017-02-01

    The volumetric (partial and apparent molar volumes) and calorimetric properties (apparent heat capacities) of aqueous cationic polyelectrolyte solutions - ionenes - were studied using the oscillating tube densitometer and differential scanning calorimeter. The polyion's charge density and the counterion properties were considered as variables. The special attention was put to evaluate the contribution of electrostatic and hydrophobic effects to the properties studied. The contribution of the CH 2 group of the polyion's backbone to molar volumes and heat capacities was estimated. Synergistic effect between polyion and counterions was found.

  14. Bilateral lower second molar impaction in teenagers: An emergent problem?

    Directory of Open Access Journals (Sweden)

    Shinohara Elio

    2010-01-01

    Full Text Available The frequency of simultaneously impacted second and third molars in teenagers is increasing and becoming a common occurrence in adolescent oral surgery practice. The traditional treatment is the removal of the third molar by conventional access but repositioning of the surgical flap to the distal face of the first molar can predispose to complications such as pericoronitis and delayed healing of the attached gingiva. We present a case in which we use the germectomy approach to remove the impacted third molar for the eruption of the second molar through a vestibular incision. This incision offers excellent bone exposure and exit route for the third molar without disturbing the gingiva attached architecture on the distal face of the first molar providing good healing environment.

  15. Partial molar volumes of organic solutes in water. XXVII. Two aliphatic polyethers (triglyme, tetraglyme) at temperatures T = 298–573 K and pressures up to 30 MPa

    International Nuclear Information System (INIS)

    Cibulka, Ivan

    2016-01-01

    Highlights: • Standard molar volumes of two linear aliphatic polyethers in water are presented. • Data were obtained in the range T from (298 to 573) K and p up to 30 MPa. • Data combined with those obtained previously are analyzed and compared with standard molar volumes of cyclic ethers. - Abstract: Densities of dilute aqueous solutions of two linear aliphatic polyethers: 2,5,8,11-tetraoxadodecane (triethylene glycol dimethyl ether, triglyme) and 2,5,8,11,14-pentaoxapentadecane (tetraethylene glycol dimethyl ether, tetraglyme), measured in the temperature range from (298 to 573) K and at pressures up to 30 MPa using an automated flow vibrating-tube densimeter are reported. Standard molar volumes were evaluated from the measured data. The present values complement previous measurements performed for the title polyethers at atmospheric pressure in the temperature range from (278 to 343) K and extend the knowledge to temperature and pressure ranges in which the data on standard molar volumes for lower members of the homologous series (monoglyme, diglyme) are already available.

  16. Image analysis of the eruptive positions of third molars and adjacent second molars as indicators of age evaluation in Thai patients

    Energy Technology Data Exchange (ETDEWEB)

    Mahasantipiya, Phattaranant May; Pramojanee, Sakarat; Thaiupathump, Trasapong [Chiang Mai University, Chiang Mai (Thailand)

    2013-12-15

    This study was performed to determine the relationship between the stage of tooth eruption (both vertical and mesio-angular) and chronological age. Indirect digital panoramic radiographs were used to measure the distances from the dentinoenamel junction (DEJ) of the second molars to the occlusal plane of the second molar teeth and of the adjacent third molars in 264 Thai males and 437 Thai females using ImageJ software. The ratio of those distances was calculated by patient age, and the correlation coefficient of the ratio of the third molar length to the second molar length was calculated. The correlation between the height of the vertically erupted upper third molar teeth and age was at the intermediate level. The age range of ≥15 to <16 years was noted to be the range in which the correlation between the chronological age determined from the eruptional height and actual chronological age was statistically significant. The mean age of the female subjects, in which the position of the right upper third molar teeth was at or above the DEJ of the adjacent second molar but below one half of its coronal height was 19.9±2.6 years. That for the left side was 20.2±2.7 years. The mean ages of the male subjects were 20.1±3.3 years and 19.8±2.7 years for the right and left sides, respectively. It might be possible to predict chronological age from the eruption height of the wisdom teeth.

  17. Image analysis of the eruptive positions of third molars and adjacent second molars as indicators of age evaluation in Thai patients

    International Nuclear Information System (INIS)

    Mahasantipiya, Phattaranant May; Pramojanee, Sakarat; Thaiupathump, Trasapong

    2013-01-01

    This study was performed to determine the relationship between the stage of tooth eruption (both vertical and mesio-angular) and chronological age. Indirect digital panoramic radiographs were used to measure the distances from the dentinoenamel junction (DEJ) of the second molars to the occlusal plane of the second molar teeth and of the adjacent third molars in 264 Thai males and 437 Thai females using ImageJ software. The ratio of those distances was calculated by patient age, and the correlation coefficient of the ratio of the third molar length to the second molar length was calculated. The correlation between the height of the vertically erupted upper third molar teeth and age was at the intermediate level. The age range of ≥15 to <16 years was noted to be the range in which the correlation between the chronological age determined from the eruptional height and actual chronological age was statistically significant. The mean age of the female subjects, in which the position of the right upper third molar teeth was at or above the DEJ of the adjacent second molar but below one half of its coronal height was 19.9±2.6 years. That for the left side was 20.2±2.7 years. The mean ages of the male subjects were 20.1±3.3 years and 19.8±2.7 years for the right and left sides, respectively. It might be possible to predict chronological age from the eruption height of the wisdom teeth.

  18. Treatment of ectopic first permanent molar teeth.

    Science.gov (United States)

    Hennessy, Joe; Al-Awadhi, E A; Dwyer, Lian O; Leith, Rona

    2012-11-01

    Ectopic eruption of the first permanent molar is a relatively common occurence in the developing dentition. A range of treatment options are available to the clinician provided that diagnosis is made early. Non-treatment can result in premature exfoliation of the second primary molar, space loss and impaction of the second premolar. This paper will describe the management of ectopic first permanent molars, using clinical examples to illustrate the available treatment options. This paper is relevant to every general dental practitioner who treats patients in mixed dentition.

  19. Annual cycle solar energy utilization with seasonal storage. Part 7. Examination on design and control of the system partially recovering exhaust heat of heat pump; Kisetsukan chikunetsu ni yoru nenkan cycle taiyo energy riyo system ni kansuru kenkyu. 7. Bubuntekina hainetsu kaishu wo koryoshita baai no sekkei seigyoho no kento

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, H; Okumiya, M [Nagoya University, Nagoya (Japan)

    1996-10-27

    The capacity and performance of the existing system that recovers the overall heating and cooling exhaust heat completely into a seasonal storage tank and the system that discharges the exhaust heat slightly to the outside and recovers it partially were compared and investigated. The system uses a central single-duct discharge system as an air-conditioning system. A heat pump and a flat-plate solar collector installed on the roof of a building are used as the heat source. The seasonal storage tank in the ground just under the building is a cylindrical water tank of 5 m deep with the concrete used as body. The upper surface of a storage tank is heat-insulated by a stylo-platform of 200 mm, and the lower side surface by a stylo-platform of 100 mm. Calculation when the difference in temperature used in a seasonal storage tank is set to 35{degree}C and 25{degree}C was performed for the system that has two control methods. The overall exhaust heat recovery system is almost the same in energy performance as the partial exhaust heat recovery system. The partial exhaust heat recovery system is more advantageous on the economic side. 4 refs., 6 figs., 3 tabs.

  20. A thermodynamic and kinetic study of the de- and rehydration of Ca(OH){sub 2} at high H{sub 2}O partial pressures for thermo-chemical heat storage

    Energy Technology Data Exchange (ETDEWEB)

    Schaube, F.; Koch, L. [German Aerospace Center, Institute of Technical Thermodynamics, Pfaffenwaldring 38-40, 70569 Stuttgart (Germany); Woerner, A., E-mail: antje.woerner@dlr.de [German Aerospace Center, Institute of Technical Thermodynamics, Pfaffenwaldring 38-40, 70569 Stuttgart (Germany); Mueller-Steinhagen, H. [German Aerospace Center, Institute of Technical Thermodynamics, Pfaffenwaldring 38-40, 70569 Stuttgart (Germany)

    2012-06-20

    Highlights: Black-Right-Pointing-Pointer Investigation of the thermodynamic equilibrium and reaction enthalpy of 'Ca(OH){sub 2} {r_reversible} CaO + H{sub 2}O'. Black-Right-Pointing-Pointer Investigation of the reaction kinetics of the dehydration of Ca(OH){sub 2} at partial pressures up to 956 mbar. Black-Right-Pointing-Pointer Investigation of the reaction kinetics of the rehydration of Ca(OH){sub 2} at partial pressures up to 956 mbar. - Abstract: Heat storage technologies are used to improve energy efficiency of power plants and recovery of process heat. Storing thermal energy by reversible thermo-chemical reactions offers a promising option for high storage capacities especially at high temperatures. Due to its low material cost, the use of the reversible reaction Ca(OH){sub 2} Rightwards-Harpoon-Over-Leftwards-Harpoon CaO + H{sub 2}O has been proposed. This paper reports on the physical properties such as heat capacity, thermodynamic equilibrium, reaction enthalpy and kinetics. To achieve high reaction temperatures, high H{sub 2}O partial pressures are required. Therefore the cycling stability is confirmed for H{sub 2}O partial pressures up to 95.6 kPa and the dehydration and hydration kinetics are studied. Quantitative data are collected and expressions are derived which are in good agreement with the presented measurements. At 1 bar H{sub 2}O partial pressure the expected equilibrium temperature is 505 Degree-Sign C and the reaction enthalpy is 104.4 kJ/mol.

  1. Heat Transfer and Thermal Stress Analysis of a Mandibular Molar Tooth Restored by Different Indirect Restorations Using a Three-Dimensional Finite Element Method.

    Science.gov (United States)

    Çelik Köycü, Berrak; İmirzalıoğlu, Pervin

    2017-07-01

    Daily consumption of food and drink creates rapid temperature changes in the oral cavity. Heat transfer and thermal stress caused by temperature changes in restored teeth may damage the hard and soft tissue components, resulting in restoration failure. This study evaluates the temperature distribution and related thermal stress on mandibular molar teeth restored via three indirect restorations using three-dimensional (3D) finite element analysis (FEA). A 3D finite element model was constructed of a mandibular first molar and included enamel, dentin, pulp, surrounding bone, and indirect class 2 restorations of type 2 dental gold alloy, ceramic, and composite resin. A transient thermal FEA was performed to investigate the temperature distribution and the resulting thermal stress after simulated temperature changes from 36°C to 4 or 60°C for a 2-second time period. The restoration models had similar temperature distributions at 2 seconds in both the thermal conditions. Compared with 60°C exposure, the 4°C condition resulted in thermal stress values of higher magnitudes. At 4ºC, the highest stress value observed was tensile stress (56 to 57 MPa), whereas at 60°C, the highest stress value observed was compressive stress (42 to 43 MPa). These stresses appeared at the cervical region of the lingual enamel. The thermal stress at the restoration surface and resin cement showed decreasing order of magnitude as follows: composite > gold > ceramic, in both thermal conditions. The properties of the restorative materials do not affect temperature distribution at 2 seconds in restored teeth. The pulpal temperature is below the threshold for vital pulp tissue (42ºC). Temperature changes generate maximum thermal stress at the cervical region of the enamel. With the highest thermal expansion coefficient, composite resin restorations exhibit higher stress patterns than ceramic and gold restorations. © 2015 by the American College of Prosthodontists.

  2. PULPOTOMIES WITH PORTLAND CEMENT IN HUMAN PRIMARY MOLARS

    Science.gov (United States)

    Conti, Taísa Regina; Sakai, Vivien Thiemy; Fornetti, Ana Paula Camolese; Moretti, Ana Beatriz Silveira; Oliveira, Thais Marchini; Lourenço, Natalino; Machado, Maria Aparecida Andrade Moreira; Abdo, Ruy Cesar Camargo

    2009-01-01

    Two clinical cases in which Portland cement (PC) was applied as a medicament after pulpotomy of mandibular primary molars in children are presented. Pulpotomy using PC was carried out in two mandibular first molars and one mandibular second molar, which were further followed-up. At the 3, 6 and 12-month follow-up appointments, clinical and radiographic examinations of the pulpotomized teeth and their periradicular area revealed that the treatments were successful in maintaining the teeth asymptomatic and preserving pulpal vitality. Additionally, the formation of a dentin bridge immediately below the PC could be observed in the three molars treated. PC may be considered as an effective alternative for primary molar pulpotomies, at least in a short-term period. Randomized clinical trials with human teeth are required in order to determine the suitability of PC before unlimited clinical use can be recommended. PMID:19148409

  3. Molar Heat Increment under Impact of Transverse Contraction in Metals

    Czech Academy of Sciences Publication Activity Database

    Pekárek, Viktor

    2007-01-01

    Roč. 52, č. 3 (2007), s. 261-268 ISSN 0001-7043 Institutional research plan: CEZ:AV0Z20570509 Keywords : atomic structure * thermal agitation * heat expansion Subject RIV: BM - Solid Matter Physics ; Magnetism

  4. Implant-supported mandibular removable partial dentures; patient-based outcome measures in relation to implant position

    NARCIS (Netherlands)

    Jensen, Charlotte; Raghoebar, Gerry M.; Kerdijk, Wouter; Meijer, Henny J. A.; Cune, Marco S.

    2016-01-01

    Objectives: To assess the benefits of implant support to Removable Partial Dentures (RPD) in patients with a bilateral free-ending situation in the mandible and to determine the most favorable implant position: the premolar (PM) or the molar (M) region. Methods: Thirty subjects with a bilateral

  5. Treatment of ectopic first permanent molar teeth.

    LENUS (Irish Health Repository)

    Hennessy, Joe

    2012-11-01

    Ectopic eruption of the first permanent molar is a relatively common occurence in the developing dentition. A range of treatment options are available to the clinician provided that diagnosis is made early. Non-treatment can result in premature exfoliation of the second primary molar, space loss and impaction of the second premolar. This paper will describe the management of ectopic first permanent molars, using clinical examples to illustrate the available treatment options. CLINICAL RELEVANCE: This paper is relevant to every general dental practitioner who treats patients in mixed dentition.

  6. In vitro comparative evaluation of cleaning efficacy and volumetric filling in primary molars: Cone beam computed tomography evaluation

    Directory of Open Access Journals (Sweden)

    Anshula Neeraj Deshpande

    2017-01-01

    Full Text Available Introduction: Pulpectomy of primary teeth is mostly carried out with hand files and broaches which is tricky and time consuming procedure. The development of new design features like varying tapers, non-cutting safety tips and varying length of cutting blades have resulted in new generation of rotary instruments. Aim: To compare and evaluate cleaning efficacy, canal preparation and volumetric filling using conventional files and rotary V Taper files through cone beam computed tomography. Materials and Method: Thirty extracted primary molars were selected. The teeth were randomly divided into three groups each containing 10 teeth i.e. 30 canals in each group. Group A was instrumented with K files; Group B rotary V Taper files and Group C was Hybrid group. Sodium hypochlorite (1% was used for irrigation. Root canal filling was done with Zinc Oxide Eugenol cement in all groups. The volumetric analysis i.e. Percentage of Volume (POV of the root canal filling in primary molars was done through CBCT Software. Result: In present study, p- value was found to be significant (<0.05. Almost 100% of canals of hybrid group were fully filled and 63.3% of canals of hand filing group were partially filled. The filling was found to be dense and no. of voids was least in hybrid group. Conclusion: Clinical time required in primary molar endodontics, especially with unpredictability and difficulty of canal morphology, is inevitable. The study confirms superior ability of rotary-file systems to shape severely curved canals with less time and significant decrease in procedural errors like partial filling, voids and inappropriate canal preparation.

  7. Internal structure of mandible around mandibular molar using computed tomography. Anatomical consideration of molar anchorage in orthodontic treatment

    International Nuclear Information System (INIS)

    Enomoto, Yutaka; Yamashita, Daisuke; Saito, Katsuhiko; Kasai, Kazutaka

    2008-01-01

    For establishment of fine occlusion, facial profile and oral function in orthodontic treatment, molar anchorage in teeth movement is important manner in extracted cases. The aims of this study were to investigate the relationship between facial morphology and internal structure of mandibular body in molar region by computer tomography, and to discuss about molar anchorage in orthodontic treatment. The data for this study were obtained from 35 modern male Japanese skulls (mean age; 27 year-old, ranged from 18 year-old to 47 year-old). Measurement variables were FMA, SN to mandibular plane angle, gonial angle, alveolar breadth, cortical bone thickness of buccal and lingual sides, and the distance between dental root and cortical bone. As a result, alveolar breadth and the distance between dental root and cortical bone were narrow in long facial type, on the contrary, these variables were wide in short facial type. The result suggested that these variables were considered important factors as molar anchorage in extracted cases. (author)

  8. Low-temperature molar heat capacities and entropies of MnO2 (pyrolusite), Mn3O4 (hausmanite), and Mn2O3 (bixbyite)

    Science.gov (United States)

    Robie, R.A.; Hemingway, B.S.

    1985-01-01

    Pyrolusite (MnO2), hausmanite (Mn3O4), and bixbyite (Mn2O3), are important ore minerals of manganese and accurate values for their thermodynamic properties are desirable to understand better the {p(O2), T} conditions of their formation. To provide accurate values for the entropies of these important manganese minerals, we have measured their heat capacities between approximately 5 and 380 K using a fully automatic adiabatically-shielded calorimeter. All three minerals are paramagnetic above 100 K and become antiferromagnetic or ferrimagnetic at lower temperatures. This transition is expressed by a sharp ??-type anomaly in Cpmo for each compound with Ne??el temperatures TN of (92.2??0.2), (43.1??0.2), and (79.45??0.05) K for MnO2, Mn3O4, and Mn2O3, respectively. In addition, at T ??? 308 K, Mn2O3 undergoes a crystallographic transition, from orthorhombic (at low temperatures) to cubic. A significant thermal effect is associated with this change. Hausmanite is ferrimagnetic below TN and in addition to the normal ??-shape of the heat-capacity maxima in MnO2 and Mn2O3, it has a second rounded maximum at 40.5 K. The origin of this subsidiary bump in the heat capacity is unknown but may be related to a similar "anomalous bump" in the curve of magnetization against temperature at about 39 K observed by Dwight and Menyuk.(1) At 298.15 K the standard molar entropies of MnO2, Mn3O4, and Mn2O3, are (52.75??0.07), (164.1??0.2), and (113.7??0.2) J??K-1??mol-1, respectively. Our value for Mn3O4 is greater than that adopted in the National Bureau of Standards tables(2) by 14 per cent. ?? 1985.

  9. Hippocampus-dependent spatial memory impairment due to molar tooth loss is ameliorated by an enriched environment.

    Science.gov (United States)

    Kondo, Hiroko; Kurahashi, Minori; Mori, Daisuke; Iinuma, Mitsuo; Tamura, Yasuo; Mizutani, Kenmei; Shimpo, Kan; Sonoda, Shigeru; Azuma, Kagaku; Kubo, Kin-ya

    2016-01-01

    Teeth are crucial, not only for mastication, but for overall nutrition and general health, including cognitive function. Aged mice with chronic stress due to tooth loss exhibit impaired hippocampus-dependent learning and memory. Exposure to an enriched environment restores the reduced hippocampal function. Here, we explored the effects of an enriched environment on learning deficits and hippocampal morphologic changes in aged senescence-accelerated mouse strain P8 (SAMP8) mice with tooth loss. Eight-month-old male aged SAMP8 mice with molar intact or with molars removed were housed in either a standard environment or enriched environment for 3 weeks. The Morris water maze was performed for spatial memory test. The newborn cell proliferation, survival, and differentiation in the hippocampus were analyzed using 5-Bromodeoxyuridine (BrdU) immunohistochemical method. The hippocampal brain-derived neurotrophic factor (BDNF) levels were also measured. Mice with upper molars removed (molarless) exhibited a significant decline in the proliferation and survival of newborn cells in the dentate gyrus (DG) as well as in hippocampal BDNF levels. In addition, neuronal differentiation of newly generated cells was suppressed and hippocampus-dependent spatial memory was impaired. Exposure of molarless mice to an enriched environment attenuated the reductions in the hippocampal BDNF levels and neuronal differentiation, and partially improved the proliferation and survival of newborn cells, as well as the spatial memory ability. These findings indicated that an enriched environment could ameliorate the hippocampus-dependent spatial memory impairment induced by molar tooth loss. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Empleo racional de la coronectomía en la extracción de terceros molares incluidos Rational application of coronectomy when treating lower impacted third molar

    Directory of Open Access Journals (Sweden)

    C. Recio Lora

    2009-08-01

    Full Text Available Los terceros molares son los dientes que, con más frecuencia, sufren el fracaso de su erupción y quedan incluidos o retenidos dentro de los maxilares. Un gran porcentaje de nuestros pacientes presentan los cordales incluidos y, de ellos, una parte importante se acompaña de patología que hace aconsejable su tratamiento quirúrgico. La técnica de la coronectomía aplicada al tercer molar incluido fue descrita por primera vez por Ecuyer y Debien en 1984 como la eliminación parcial de dicho diente, dejando deliberadamente parte de su raíz en el interior de la mandíbula. Fue propuesta para evitar la lesión del nervio dentario inferior (NDI en aquéllos casos en los que existía una íntima relación entre ambas estructuras anatómicas. Aunque el objetivo de la técnica es muy claro, no está libre de controversia, ya que el cirujano debe valorar la posibilidad de una complicación infecciosa de origen pulpar. Presentamos un caso clínico exitoso de esta técnica, junto al análisis de la postura ante la técnica de los distintos autores, así como sus ventajas e inconvenientes.Third molars are the teeth that most frequently fail to erupt and remain impacted or retained inside the bone. A large percentage of our patients have impacted wisdom teeth and many of these patients also have pathologies that require surgical treatment. Applied coronectomy technique of the impacted third molar was first described by Ecuyer and Debien in 1984. The described it as partial elimination of the tooth in question, deliberately leaving part of the root inside the bone. This was proposed to avoid injuring the inferior dental nerve in cases where there was a close relationship between the two anatomical structures. Although the objective of the procedure is very clear, it is still controversial. Therefore, the surgeon should evaluate the possibility of an infectious complication of pulpar origin. We present the successful clinical case that uses this technique

  11. A notable difference between ideal gas and infinite molar volume limit of van der Waals gas

    International Nuclear Information System (INIS)

    Liu, Q H; Shen, Y; Bai, R L; Wang, X

    2010-01-01

    The van der Waals equation of state does not sufficiently represent a gas unless a thermodynamic potential with two proper and independent variables is simultaneously determined. The limiting procedures under which the behaviour of the van der Waals gas approaches that of an ideal gas are letting two van der Waals coefficients be zero rather than letting the molar volume become infinitely large; otherwise, the partial derivative of internal energy with respect to pressure at a fixed temperature does not vanish.

  12. A notable difference between ideal gas and infinite molar volume limit of van der Waals gas

    Science.gov (United States)

    Liu, Q. H.; Shen, Y.; Bai, R. L.; Wang, X.

    2010-05-01

    The van der Waals equation of state does not sufficiently represent a gas unless a thermodynamic potential with two proper and independent variables is simultaneously determined. The limiting procedures under which the behaviour of the van der Waals gas approaches that of an ideal gas are letting two van der Waals coefficients be zero rather than letting the molar volume become infinitely large; otherwise, the partial derivative of internal energy with respect to pressure at a fixed temperature does not vanish.

  13. Radiographic evaluation of bone regeneration after the application of plasma rich in growth factors in a lower third molar socket: a case report

    Science.gov (United States)

    2009-01-01

    A 42-year-old Mediterranean male presented complaining of inability to sustain good oral care at the posterior aspect of the lower right jaw. The main problems were food impaction in the area and the subsequent malodor. The patient reported remarkable medical history. Clinical examination revealed local erytherma with noticeable bone defect distal to the second molar with obvious defect in the mesial wall of the third molar; the penetration depth was found to be up to 6 mm. Radiological evaluation confirmed the defect and it was attributed to the mesioangularly partially impacted lower third molar. It was decided that third molar should be extracted and concentrate of the patient's growth factors (PRGF) to be applied into the bony defect to stimulate bone regeneration and promote healing. The third molar tooth was, then, removed surgically and the PRGF, which was prepared preoperatively, was implanted in the socket. At the first postoperative day, moderate pain was the main complaint and was controlled by NSAIDs. One week postoperatively, the sutures were removed and there was good tissue healing on examination. On the fiftieth postoperative day, radiographic evaluation took place and showed noticeable enhancement of density and radio-opacity in the third molar socket area, in comparison with the baseline image. Further, clinical examination showed significant reduction of periodontal pocketing and evidence of new bone formation. In conclusion, PRGF was very successful in stimulating bone regeneration and promote healing following dental extraction. PMID:20062651

  14. Adhesives for bonded molar tubes during fixed brace treatment.

    Science.gov (United States)

    Millett, Declan T; Mandall, Nicky A; Mattick, Rye Cr; Hickman, Joy; Glenny, Anne-Marie

    2017-02-23

    Orthodontic treatment involves using fixed or removable appliances (dental braces) to correct the positions of teeth. The success of a fixed appliance depends partly on the metal attachments (brackets and bands) being glued to the teeth so that they do not become detached during treatment. Brackets (metal squares) are usually attached to teeth other than molars, where bands (metal rings that go round each tooth) are more commonly used. Orthodontic tubes (stainless steel tubes that allow wires to pass through them), are typically welded to bands but they may also be glued directly (bonded) to molars. Failure of brackets, bands and bonded molar tubes slows down the progress of treatment with a fixed appliance. It can also be costly in terms of clinical time, materials and time lost from education/work for the patient. This is an update of the Cochrane review first published in 2011. A new full search was conducted on 15 February 2017 but no new studies were identified. We have only updated the search methods section in this new version. The conclusions of this Cochrane review remain the same. To evaluate the effectiveness of the adhesives used to attach bonded molar tubes, and the relative effectiveness of the adhesives used to attach bonded molar tubes versus adhesives used to attach bands, during fixed appliance treatment, in terms of: (1) how often the tubes (or bands) come off during treatment; and (2) whether they protect the bonded (or banded) teeth against decay. The following electronic databases were searched: Cochrane Oral Health's Trials Register (to 15 February 2017), the Cochrane Central Register of Controlled Trials (CENTRAL; 2017, Issue 1) in the Cochrane Library (searched 15 February 2017), MEDLINE Ovid (1946 to 15 February 2017), and Embase Ovid (1980 to 15 February 2017). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials. No restrictions were placed on the language or

  15. Actitud terapéutica ante sacos foliculares de terceros molares incluídos Therapeutic approach to impacted third molar follicles

    Directory of Open Access Journals (Sweden)

    R. González García

    2005-04-01

    Full Text Available El quiste dentígero o folicular es un quiste odontogénico del desarrollo. Está revestido por el epitelio del folículo dentario, y suele estar en relación con un diente permanente incluído. Presentamos el caso clínico de un paciente en el que se observa la aparición de un quiste dentígero a partir del saco folicular de un tercer molar incluído no exodonciado, y lo comparamos con la evolución de un cordal incluído y su saco folicular contralaterales en los que se realizó la exodoncia. El tratamiento definitivo del quiste dentígero asociado a un tercer molar incluído es quirúrgico, con la exodoncia de la pieza y enucleación del quiste. Los sacos foliculares mayores de 2 mm asociados a terceros molares incluídos evolucionan en numerosas ocasiones a quistes foliculares. Está indicada la exodoncia de dichos cordales para evitar la evolución a quiste dentígero.The dentigerous cyst or follicular cyst is a developmental odontogenic cyst. It is covered by the epithelium of the dental follicle, and it tends to be related to an impacted permanent tooth. The case report of a patient who was seen to develop a dentigerous cyst arising from the follicle of an impacted non-extracted third molar is presented. This is then compared with the evolution of the contralateral impacted third molar and its follicle that was extracted. The definitive treatment for a dentigerous cyst associated with an impacted third molar is surgical, the extraction of the tooth and enucleation of the cyst. Follicles measuring more+ than 2 mm and that are associated with impacted third molars often develop into follicular cysts. The extraction of these third molars is indicated in order to avoid the development of a dentigerous cyst

  16. Introduction to partial differential equations

    CERN Document Server

    Greenspan, Donald

    2000-01-01

    Designed for use in a one-semester course by seniors and beginning graduate students, this rigorous presentation explores practical methods of solving differential equations, plus the unifying theory underlying the mathematical superstructure. Topics include basic concepts, Fourier series, second-order partial differential equations, wave equation, potential equation, heat equation, approximate solution of partial differential equations, and more. Exercises appear at the ends of most chapters. 1961 edition.

  17. Presence of third molars in orthodontic patients from northern Greece

    Directory of Open Access Journals (Sweden)

    Barka G

    2012-05-01

    Full Text Available Georgia Barka,1 Georgios Tretiakov,1 Theodosios Theodosiou,2 Ioulia Ioannidou-Marathiotou31School of Dentistry, 2Biostatistics, Department of Informatics, School of Natural Sciences, 3Department of Orthodontics, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, GreeceObjective: The purpose of the present study was to investigate the frequency of presence of third molar teeth and their distribution in each jaw and each side, according to sex, in a group of orthodontic patients with permanent dentition from northern Greece.Methods: The sample included panoramic radiographs from 220 patients with permanent dentition (mean age 13.62 ± 1.81. The Χ2 test was used to assess the relationships between the variables, and the Fisher's exact test was used in cases where the expected frequencies in each cell were <5.Results: The frequency of third molar presence was 79.1%, and 20.9% was the frequency of third molar agenesis. Intersexual differences in the number of third molars was not statistically significant. There was a correlation between the distribution of third molars on the right and the left side (Fisher's exact test = 100.788; P = 0. The two sides showed the same tendency toward the presence or absence of third molars. A correlation was also found between the distribution of maxillary and mandibular third molars (Fisher's exact test = 24.372; P = 0. In each jaw, the presence or absence of third molars was highly related to the number of third molars found in the other jaw.Conclusion: The present results showed that in this orthodontic group of northern Greek patients, presence accounted for 79.1% and agenesis for 20.9%. No significant difference was found between the frequencies of third molar presence on the left and right sides in either the maxilla or mandible.Keywords: third molars, presence, orthodontic population, Greeks

  18. Results of the mockup experiment on partial LOCA

    International Nuclear Information System (INIS)

    Dreier, J.; Winkler, H.

    1985-01-01

    A mockup experiment has been performed to verify the heat transfer model for a partial loss of coolant accident in the swimming pool reactor SAPHIR. Three coolant channels with the same dimensions as in a SAPHIR fuel element were simulated using four electrically heated plates. For a water level such that the heated plates are partially submerged, plate temperatures remain below 160 0 C for plate powers of up to 650 W. For water levels low enough to just block the channels, plate temperatures of 400 0 C are reached for plate powers as low as 60 W. Details of the experiment and further results are discussed

  19. Molar Incisor Hypomineralisation

    NARCIS (Netherlands)

    Elfrink, M.; Weerheijm, K.L.

    2013-01-01

    Molar Incisor Hypomineralisation (mih) wordt omschreven als een hypomineralisatie (van systemische oorsprong) van één tot vier blijvende eerste molaren, vaak in combinatie met aangedane incisieven. mih-molaren zijn fragieler en cariësgevoeliger dan gewone molaren. Een kenmerk van mih-molaren is een

  20. Molar Incisor Hypomineralisation

    NARCIS (Netherlands)

    Elfrink, M.; Weerheijm, K.L.

    2009-01-01

    Molar Incisor Hypomineralisation (MIH) wordt gedefinieerd als een hypomineralisatie van systemische oorsprong van één tot vier blijvende eerste molaren, vaak in combinatie met aangedane incisieven. MIH-molaren zijn fragieler en cariësgevoeliger dan gewone molaren. Een kenmerk van MIH-molaren is een

  1. Molar Incisor Hypomineralisation

    NARCIS (Netherlands)

    Elfrink, M.; Weerheijm, K.

    2011-01-01

    Molar Incisor Hypomineralisation (mih ) wordt gedefinieerd als een hypomineralisatie van systemische oorsprong van één tot vier blijvende eerste molaren, vaak in combinatie met aangedane incisieven. mih -molaren zijn fragieler en cariësgevoeliger dan gewone molaren. Een kenmerk van mih -molaren is

  2. The not-so-harmless maxillary primary first molar extraction.

    Science.gov (United States)

    Northway, W M

    2000-12-01

    Premature loss of primary molars has been associated with space loss and eruptive difficulties, especially when the loss occurs to the primary second molars and when it occurs early. This has not been thought to be the case for primary first molars. The author revisited 13 cases from an earlier study on the effects of premature loss of maxillary primary molars. These longitudinal cases were scrutinized, using serial panoramic radiographs, to explain the irregular response in terms of dental migration. The author presents two case reports. In the earlier study, the author used digitized study casts and the concept of D + E space--the space occupied by the primary first and second molars--to describe the dental migration that occurred after premature tooth loss. Using analysis of variance on data generated using an instrument capable of measuring in tenths of millimeters, the author produced findings regarding the amount of space loss, rate of space loss, effect of age at loss, amount of space regained at the time of replacement by the permanent tooth and effect on Angle's classification. Finally, the author created a simulation describing directional change; this revealed that the maxillary primary first molar loss resulted in a mesial displacement of the permanent canine during eruption. When the maxillary primary first molar is lost prematurely, the first premolar erupts in a more mesial direction than normal, as a result of the mesial incline of the primary second molar, and consumes the space of the permanent canine, which becomes blocked out. Rather than use a space maintainer after the premature loss of the maxillary primary first molar, the author suggests, clinicians can choose from a number of other options for preventing the first premolar from erupting too far in a mesial direction.

  3. Liquid phase PVTx properties of (water + tert-butanol) binary mixtures at temperatures from 278.15 to 323.15 K and pressures from 0.1 to 100 MPa. II. Molar isothermal compressions, molar isobaric expansions, molar thermal pressure coefficients, and internal pressure

    International Nuclear Information System (INIS)

    Egorov, Gennadiy I.; Makarov, Dmitriy M.; Kolker, Arkadiy M.

    2013-01-01

    Highlights: ► Molar isothermal compressions and molar isobaric expansions were evaluated. ► Coefficients of thermal pressure and internal pressure were obtained. ► Concentration dependences of coefficients under study display extremes. ► Temperature and pressure dependences of internal pressure of the mixture were linear. -- Abstract: Molar isothermal compressions, molar isobaric expansions, molar coefficients of thermal pressure, and internal pressure were calculated over the whole concentration range of {water (1) + tert-butanol (2)} mixture at pressures from 0.1 to 100 MPa and temperatures from 278.15 to 323.15 K. It was revealed that the extremes, observed on concentration dependences of molar isothermal compression K T,m and molar isobaric expansion E P,m of the mixture, became more pronounced with pressure growth and temperature lowering. Values of molar thermal pressure coefficients of the mixture sharply rose at compositions with small TBA mole fraction and then decreased practically linearly with the alcohol content increasing. Temperature and pressure dependences of the mixture internal pressure were almost linear, and at low TBA concentrations changed significantly from the dependences of water, tert-butanol and their mixtures at large alcohol content

  4. Ultrasonic velocities, densities, and excess molar volumes of binary mixtures of N,N-dimethyl formamide with methyl acrylate, or ethyl acrylate, or butyl acrylate, or 2-ethyl hexyl acrylate at T = 308.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Kondaiah, M. [Department of Physics, Acharya Nagarjuna University, Nagarjuna Nagar 522510, Andhra Pradesh (India); Sravana Kumar, D. [Dr. V.S. Krishna Govt. Degree College, Visakhapatnam, Andhra Pradesh (India); Sreekanth, K. [Department of Physics, Acharya Nagarjuna University, Nagarjuna Nagar 522510, Andhra Pradesh (India); Krishna Rao, D., E-mail: krdhanekula@yahoo.co.in [Department of Physics, Acharya Nagarjuna University, Nagarjuna Nagar 522510, Andhra Pradesh (India)

    2011-12-15

    Highlights: > Positive values of V{sub m}{sup E}, indicate dispersion forces between acrylic esters and DMF. > V{sub m}{sup E} values compared with Redlich-Kister polynomial. > Partial molar volumes data conclude that weak interactions exist in the systems. > Measured velocity values compared with theoretical values obtained by polynomials. - Abstract: Ultrasonic velocities, u, densities, {rho}, of binary mixtures of N,N-dimethyl formamide (DMF) with methyl acrylate (MA), ethyl acrylate (EA), butyl acrylate (BA), and 2-ethyl hexyl acrylate (EHA), including pure liquids, over the entire composition range have been measured at T = 308.15 K. Using the experimental results, the excess molar volume, V{sub m}{sup E}, partial molar volumes, V-bar {sub m,1}, V-bar{sub m,2}, and excess partial molar volumes, V-bar{sub m,1}{sup E}, V-bar{sub m,2}{sup E} have been calculated. Molecular interactions in the systems have been studied in the light of variation of excess values of calculated properties. The excess properties have been fitted to Redlich-Kister type polynomial and the corresponding standard deviations have been calculated. The positive values of V{sub m}{sup E} indicate the presence of dispersion forces between the DMF and acrylic ester molecules. Further theoretical values of sound velocity in the mixtures have been evaluated using various theories and have been compared with experimental sound velocities to verify the applicability of such theories to the systems studied. Theoretical ultrasonic velocity data have been used to study molecular interactions in the binary systems investigated.

  5. Standard molar enthalpy of formation of methoxyacetophenone isomers

    International Nuclear Information System (INIS)

    Amaral, Luísa M.P.F.; Morais, Victor M.F.; Ribeiro da Silva, Manuel A.V.

    2014-01-01

    Highlights: • Experimental and computational energetic study of methoxyacetophenone isomers. • Enthalpies of formation and phase transition determined by calorimetric techniques. • Quantum chemical calculations allowed estimation of enthalpies of formation. • Structure and energy correlations were established. - Abstract: Values of the standard (p o = 0.1 MPa) molar enthalpy of formation of 2′-, 3′- and 4′-methoxyacetophenones were derived from their standard molar energy of combustion, in oxygen, at T = 298.15 K, measured by static bomb combustion calorimetry. The Calvet high temperature vacuum sublimation technique was used to measure the enthalpies of sublimation/vaporization of the compounds studied. The standard molar enthalpies of formation of the three compounds, in the gaseous phase, at T = 298.15 K, have been derived from the corresponding standard molar enthalpies of formation in the condensed phase and the standard molar enthalpies for the phase transition. The results obtained are −(232.0 ± 2.5), −(237.7 ± 2.7) and −(241.1 ± 2.1) kJ · mol −1 for 2′-, 3′- and 4′-methoxyacetophenone, respectively. Standard molar enthalpies of formation were also estimated from different methodologies: the Cox scheme as well as two different computational approaches using density functional theory-based B3LYP and the multilevel G3 methodologies

  6. Three-Dimensional, Numerical Investigation of Flow and Heat Transfer in Rectangular Channels Subject to Partial Blockage

    KAUST Repository

    Salama, Amgad; El-Amin, Mohamed; Sun, Shuyu

    2014-01-01

    Numerical simulation of flow and heat transfer in two adjacent channels is conducted with one of the channels partially blocked. This system simulates typical channels of a material testing reactor. The blockage is assumed due to the buckling of one of the channel plates inward along its width. The blockage ratio considered in this work is defined as the ratio between the cross-sectional area of the blocked and the unblocked channel. In this work, we consider a blockage ratio of approximately 40%. However, the blockage is different along the width of the channel, ranging from 0% at the end of the channel to 90% in the middle. The channel walls are sandwiching volumetric heat sources that vary spatially as chopped cosine functions. Interesting patterns are highlighted and investigated. The reduction in the flow area of one channel results in the flow redistributing among the two channels according to the changes in their hydraulic conductivities. The results of the numerical simulations show that the maximum wall temperature in the blocked channel is well below the boiling temperature at the operating pressure.

  7. Three-Dimensional, Numerical Investigation of Flow and Heat Transfer in Rectangular Channels Subject to Partial Blockage

    KAUST Repository

    Salama, Amgad

    2014-08-25

    Numerical simulation of flow and heat transfer in two adjacent channels is conducted with one of the channels partially blocked. This system simulates typical channels of a material testing reactor. The blockage is assumed due to the buckling of one of the channel plates inward along its width. The blockage ratio considered in this work is defined as the ratio between the cross-sectional area of the blocked and the unblocked channel. In this work, we consider a blockage ratio of approximately 40%. However, the blockage is different along the width of the channel, ranging from 0% at the end of the channel to 90% in the middle. The channel walls are sandwiching volumetric heat sources that vary spatially as chopped cosine functions. Interesting patterns are highlighted and investigated. The reduction in the flow area of one channel results in the flow redistributing among the two channels according to the changes in their hydraulic conductivities. The results of the numerical simulations show that the maximum wall temperature in the blocked channel is well below the boiling temperature at the operating pressure.

  8. Angulation change of the third molar tooth in orthodontic treatment

    Directory of Open Access Journals (Sweden)

    Ardiansyah S. Pawinru

    2017-04-01

    Full Text Available Objective : Impaction of the third molar tooth mandibular is often found in patients with orthodontic treatment. In orthodontic treatment, extraction cases of impaction of the third molar tooth are usually performed, but the patients often refuse this extraction. Extraction of premolar has a good effect on the third molar mandibular angulation during treatment. Material and Methods : This study is a retrospective clinical study with descriptive analytic to find out the effect of the first mandibular premolar tooth extraction to angulation change of the third molar mandibular in orthodontic treatment with a standard edgewise method. Angulation change was performed by comparing the third molar mandibular angulation before and after orthodontic treatment with panoramic radiographs. Angulation of the third molar tooth mandibular was calculated from the angle formed between the long axis of the tooth with the reference line infraorbita. Results : The sample comprised 60 of impacted mandibular third molar region of the left and right regions of 30 patients who had been treated declared cured in clinic of orthodontic specialist of Dentistry Faculty Padjadjaran University. The sample was divided into three (3 groups of patients before treatment angulation of the third molar tooth mandibular under 300, 300 to 600 and above 60o, then measured change of angulation and observed whether it increased, fixed or decreased. Results were analyzed by T- test and Wilcoxon test showed that there was a significant change in angulation of the third molar mandibular in orthodontic treatment with the first premolar tooth mandibular extraction. Conclusion : This study is that the first premolar tooth mandibular extraction affects the angulation of the third molar tooth mandibular after orthodontic treatment.

  9. Variation and decomposition of the partial molar volume of small gas molecules in different organic solvents derived from molecular dynamics simulations.

    Science.gov (United States)

    Klähn, Marco; Martin, Alistair; Cheong, Daniel W; Garland, Marc V

    2013-12-28

    The partial molar volumes, V(i), of the gas solutes H2, CO, and CO2, solvated in acetone, methanol, heptane, and diethylether are determined computationally in the limit of infinite dilution and standard conditions. Solutions are described with molecular dynamics simulations in combination with the OPLS-aa force field for solvents and customized force field for solutes. V(i) is determined with the direct method, while the composition of V(i) is studied with Kirkwood-Buff integrals (KBIs). Subsequently, the amount of unoccupied space and size of pre-formed cavities in pure solvents is determined. Additionally, the shape of individual solvent cages is analyzed. Calculated V(i) deviate only 3.4 cm(3) mol(-1) (7.1%) from experimental literature values. Experimental V(i) variations across solutions are reproduced qualitatively and also quantitatively in most cases. The KBI analysis identifies differences in solute induced solvent reorganization in the immediate vicinity of H2 (<0.7 nm) and solvent reorganization up to the third solvation shell of CO and CO2 (<1.6 nm) as the origin of V(i) variations. In all solutions, larger V(i) are found in solvents that exhibit weak internal interactions, low cohesive energy density and large compressibility. Weak internal interactions facilitate solvent displacement by thermal solute movement, which enhances the size of solvent cages and thus V(i). Additionally, attractive electrostatic interactions of CO2 and the solvents, which do not depend on internal solvent interactions only, partially reversed the V(i) trends observed in H2 and CO solutions where electrostatic interactions with the solvents are absent. More empty space and larger pre-formed cavities are found in solvents with weak internal interactions, however, no evidence is found that solutes in any considered solvent are accommodated in pre-formed cavities. Individual solvent cages are found to be elongated in the negative direction of solute movement. This wake behind

  10. Variation and decomposition of the partial molar volume of small gas molecules in different organic solvents derived from molecular dynamics simulations

    Science.gov (United States)

    Klähn, Marco; Martin, Alistair; Cheong, Daniel W.; Garland, Marc V.

    2013-12-01

    The partial molar volumes, bar V_i, of the gas solutes H2, CO, and CO2, solvated in acetone, methanol, heptane, and diethylether are determined computationally in the limit of infinite dilution and standard conditions. Solutions are described with molecular dynamics simulations in combination with the OPLS-aa force field for solvents and customized force field for solutes. bar V_i is determined with the direct method, while the composition of bar V_i is studied with Kirkwood-Buff integrals (KBIs). Subsequently, the amount of unoccupied space and size of pre-formed cavities in pure solvents is determined. Additionally, the shape of individual solvent cages is analyzed. Calculated bar V_i deviate only 3.4 cm3 mol-1 (7.1%) from experimental literature values. Experimental bar V_i variations across solutions are reproduced qualitatively and also quantitatively in most cases. The KBI analysis identifies differences in solute induced solvent reorganization in the immediate vicinity of H2 (<0.7 nm) and solvent reorganization up to the third solvation shell of CO and CO2 (<1.6 nm) as the origin of bar V_i variations. In all solutions, larger bar V_i are found in solvents that exhibit weak internal interactions, low cohesive energy density and large compressibility. Weak internal interactions facilitate solvent displacement by thermal solute movement, which enhances the size of solvent cages and thus bar V_i. Additionally, attractive electrostatic interactions of CO2 and the solvents, which do not depend on internal solvent interactions only, partially reversed the bar V_i trends observed in H2 and CO solutions where electrostatic interactions with the solvents are absent. More empty space and larger pre-formed cavities are found in solvents with weak internal interactions, however, no evidence is found that solutes in any considered solvent are accommodated in pre-formed cavities. Individual solvent cages are found to be elongated in the negative direction of solute

  11. Rare occurrence of the left maxillary horizontal third molar impaction ...

    African Journals Online (AJOL)

    Rare occurrence of the left maxillary horizontal third molar impaction, the right maxillary third molar vertical impaction and the left mandibular third molar vertical impaction with inferior alveolar nerve proximity in a 30 year old female: a case report.

  12. The contemporary management of third molars.

    Science.gov (United States)

    Hyam, D M

    2018-03-01

    The management of third molars requires a significant assessment and decision process both for the patient and the clinician. The clinician must always identify the indication for third molar surgery, assess the risks of the proposed procedure, and then modify their plan to account for the patient's current and future health, their social and financial setting, and the patient's tolerance of risk. In doing this, the clinician can tailor a solution to meet the individual patient's needs. This decision to remove a third molar is made in the fluid setting of the patient's quality of life and requires regular review. This article gives the clinician the tools, the matrix, and the confidence to guide patients through this process, and outlines some of the pitfalls and common points of bias within the process. © 2018 Australian Dental Association.

  13. Partial differential equations of mathematical physics

    CERN Document Server

    Sobolev, S L

    1964-01-01

    Partial Differential Equations of Mathematical Physics emphasizes the study of second-order partial differential equations of mathematical physics, which is deemed as the foundation of investigations into waves, heat conduction, hydrodynamics, and other physical problems. The book discusses in detail a wide spectrum of topics related to partial differential equations, such as the theories of sets and of Lebesgue integration, integral equations, Green's function, and the proof of the Fourier method. Theoretical physicists, experimental physicists, mathematicians engaged in pure and applied math

  14. [Evaluation of cermet fillings in abutment teeth in removable partial prostheses].

    Science.gov (United States)

    Saulic, S; Tihacek-Sojic, Lj

    2001-01-01

    The aim of the study was to describe the clinical process of setting the purpose filling on abutment teeth, after finishing the removable partial dentures. The aim was also to investigate the use of cermet glass-ionomer cement for the purpose filling in the abutment teeth for removable partial dentures, as well as to investigate the surface of the purpose filling. For the clinical evaluation of purpose filling slightly modified criteria according to Ryg's were used in 20 patients with different type of edentulousness. Changes occurring on the surface of purpose filling have been experimentally established by the method of scanning electron microscopy on the half-grown third molars in seven patients. It could be concluded that cement glass-ionomer was not the appropriate material for the purpose fillings in abutment teeth for removable partial dentures.

  15. Cuartos molares supernumerarios: relato de caso clínico

    Directory of Open Access Journals (Sweden)

    Daniela Nascimento Silva

    2006-04-01

    Full Text Available Los dientes supernumerarios se diagnostican mediante exámenes radiográficos de rutina, pues generalmente son asintomáticos. Los cuartos molares representan el segundo grupo de dientes supernumerarios con más frecuencias; ocurren en posición distal a los terceros molares, especialmente en el maxilar superior, y en la mayoría de casos, estos están incluidos. El objetivo de este artículo es realizar la presentación de un caso, de una mujer de 30 anos con los cuartos molares incluidos en el maxilar inferior y describir la técnica para su remoción.Supernumerary teeth are generally asymptomatic and are diagnosed by routine X-ray tests. The fourth molar teeth represent the second group of the most frequent supernumerary teeth, occur in distal position to the third molar teeth, specially in the superior maxilla and, in most of the cases, they are included. The aim of this paper is to comment on the case of a 30-year-old woman with the fourth molar teeth included in the inferior maxilla and to describe the technique used for their removal.

  16. Impacted third molar transplantation on the malpracticed extraction socket.

    Science.gov (United States)

    Kim, Soung Min; Amponsah, Emmanuel K

    2017-12-01

    Autotransplantation with or without endodontic therapy is regarded as an alternative treatment option for the replacement of missing teeth. A primary responsibility of a maxillofacial surgeon is to reverse any malpractice to promote successful outcomes and improve the patient's quality of life. This paper presents a malpractice case of incorrect extraction of the lower second molar instead of the impacted third molar. A simple technique of transplanting the impacted third molar to the site of the extracted second molar is introduced by a maxillofacial specialist in Ghana. By making an intentional root socket and fixation without using additional appliances, a novel second molar was achieved with complete recovery. This patient was followed after transplant for a four-year period with the best satisfaction. A grant of the Korean Health Technology R&D Project, Ministry of Health & Welfare, Republic of Korea. (HI15C0689).

  17. Mathematical programming model for heat exchanger design through optimization of partial objectives

    International Nuclear Information System (INIS)

    Onishi, Viviani C.; Ravagnani, Mauro A.S.S.; Caballero, José A.

    2013-01-01

    Highlights: • Rigorous design of shell-and-tube heat exchangers according to TEMA standards. • Division of the problem into sets of equations that are easier to solve. • Selected heuristic objective functions based on the physical behavior of the problem. • Sequential optimization approach to avoid solutions stuck in local minimum. • The results obtained with this model improved the values reported in the literature. - Abstract: Mathematical programming can be used for the optimal design of shell-and-tube heat exchangers (STHEs). This paper proposes a mixed integer non-linear programming (MINLP) model for the design of STHEs, following rigorously the standards of the Tubular Exchanger Manufacturers Association (TEMA). Bell–Delaware Method is used for the shell-side calculations. This approach produces a large and non-convex model that cannot be solved to global optimality with the current state of the art solvers. Notwithstanding, it is proposed to perform a sequential optimization approach of partial objective targets through the division of the problem into sets of related equations that are easier to solve. For each one of these problems a heuristic objective function is selected based on the physical behavior of the problem. The global optimal solution of the original problem cannot be ensured even in the case in which each of the sub-problems is solved to global optimality, but at least a very good solution is always guaranteed. Three cases extracted from the literature were studied. The results showed that in all cases the values obtained using the proposed MINLP model containing multiple objective functions improved the values presented in the literature

  18. Calorimetric determination of the heat of precipitation of pseudoephedrine racemic compound--its agreement with the heat of solution.

    Science.gov (United States)

    Pudipeddi, M; Sokoloski, T D; Duddu, S P; Carstensen, J T

    1995-10-01

    The heat of precipitation of dl-pseudoephedrine was determined by direct calorimetry using a Tronac isoperibolic calorimeter. The precipitation of dl-pseudoephedrine was induced by mixing aqueous solutions of the two enantiomers, namely, d- and l-pseudoephedrine, directly in the calorimeter. The molar heat of precipitation of dl-pseudoephedrine was -2.7 and -3.0 kcal/mol at 25 and 30 degrees C, respectively. The aqueous solubility of dl-pseudoephedrine was determined over a temperature range of 20-40 degrees C. The van't Hoff solubility plot was nonlinear. The apparent heat of solution at saturation was obtained from the solubility data using a nonlinear regression model. A good agreement between the magnitude of the apparent heat of solution at saturation and the heat of precipitation was noticed at both 25 and 30 degrees C.

  19. Estudio de volumen molar y refracción molar de miscelas de triglicéridos (triacetina, tributirina o tricaprilina y alcoholes (etanol, 1-butanol o 1-hexanol

    Directory of Open Access Journals (Sweden)

    Rodríguez Rodríguez, M.

    1992-12-01

    Full Text Available Values of molar refraction for every studied mixtures show linear plots versus molar fractions of triglyceride. Values of molar volume show this behaviour, but only for tributyrin-butanol or tricaprylin-butanol miscellas. However, in tributyrin-ethanol mixtures, volume contractions have been found, whereas triacetin-butanol and tributyrin-hexanol show volume expansions. These facts are related to the mode of being structured of the alcohol and triglyceride molecules in mixtures. A linear relationship between molar volume and temperature have been found, and also a linear dependence between the coefficient of thermal expansion at constant pressure and the molar fraction of triglyceride.

    Los valores de la refracción molar en todas las miscelas estudiadas presentan variaciones lineales frente a la fracción molar de triglicérido. la misma variación que presentan los valores del volumen molar de las miscelas tributirina y tricaprilina en butanol. Sin embargo, en las miscelas de tributirina-etanol se encuentran contracciones de volumen mientras que en las de triacetina-butanol y tributirina-hexanol expansiones, atribuidas en ambos casos a la forma de estructurarse las moléculas de alcohol y triglicérido en las miscelas. Por otra parte, se encuentra una variación lineal entre el volumen molar de las miscelas y la temperatura, y se establece una relación lineal entre el coeficiente de dilatación térmico molar a presión constante y la fracción molar de triglicérido en los cinco sistemas estudiados.

  20. Elective extractions of first permanent molars: a review

    Directory of Open Access Journals (Sweden)

    Melike Kiraz

    2018-05-01

    Full Text Available Permanent first molar teeth possess a key role in the setting-up of the occlusion, contribute significantly to the chewing function and serve as a guide for other teeth. However, it is frequently encountered that permanent first molar teeth are extracted due to the predicted negative prognoses of caries or developmental defects. As a result of the uncontrolled extraction of the permanent first molar teeth during the growth and development period, drifting of adjacent teeth, continued eruption of the opposing teeth and displacements can be seen. Furthermore, following one-sided extraction, midline deviations, oppositional tooth eruption, skeletal and dental asymmetry, unilateral chewing habits, and temporo-mandibular joint disorders may occur. To prevent these pathological conditions and to maintain the stability of the occlusal relation, it is necessary to do compensation and balancing extractions of the permanent first molar teeth on the opposite/symmetric arc, assuming mesial drag of the permanent second and third molar teeth. With such controlled-extractions, especially in Class I cases, orthodontic or prosthetic treatments, which may require extra time, cost and effort, could be prevented and a conceivable occlusion can be established.

  1. Partial Pressures of Te2 and Thermodynamic Properties of Ga-Te System

    Science.gov (United States)

    Su, Ching-Hua; Curreri, Peter A. (Technical Monitor)

    2001-01-01

    The partial pressures of Te2 in equilibrium with Ga(1-x)Te(x) samples were measured by optical absorption technique from 450 to 1100 C for compositions, x, between 0.333 and 0.612. To establish the relationship between the partial pressure of Te, and the measured optical absorbance, the calibration runs of a pure Te sample were also conducted to determine the Beer's Law constants. The partial pressures of Te2 in equilibrium with the GaTe(s) and Ga2Te3(s)compounds, or the so-called three-phase curves, were established. These partial pressure data imply the existence of the Ga3Te4(s) compound. From the partial pressures of Te2 over the Ga-Te melts, partial molar enthalpy and entropy of mixing for Te were derived and they agree reasonable well with the published data. The activities of Te in the Ga-Te melts were also derived from the measured partial pressures of Te2. These data agree well with most of the previous results. The possible reason for the high activity of Te measured for x less than 0.60 is discussed.

  2. Influence of Implant Position on Stress Distribution in Implant-Assisted Distal Extension Removable Partial Dentures: A 3D Finite Element Analysis.

    Science.gov (United States)

    Memari, Yeganeh; Geramy, Allahyar; Fayaz, Amir; Rezvani Habib Abadi, Shirin; Mansouri, Yasaman

    2014-09-01

    Distal extension removable partial denture is a prosthesis with lack of distal dental support with a 13-fold difference in resiliency between the mucosa and the periodontal ligament, resulting in leverage during compression forces. It may be potentially destructive to the abutments and the surrounding tissues. The aim of this study was to assess the effect of implant location on stress distribution, in distal extension implant assisted removable partial dentures. Three-dimensional models of a bilateral distal extension partially edentulous mandible containing anterior teeth and first premolar in both sides of the arch, a partial removable denture and an implant (4×10mm) were designed. With the aid of the finite element program ANSYS 8.0, the models were meshed and strictly vertical forces of 10 N were applied to each cusp tip. Displacement and von Mises Maps were plotted for visualization of results. When an implant was placed in the second premolar region, the highest stress on implant, abutment tooth and cancellous bone was shown. The lowest stress was shown on implant and bone in the 1(st) molar area. Implants located in the first molar area showed the least distribution of stresses in the analyzed models.

  3. Pattern of third molar impaction in a Saudi population

    Directory of Open Access Journals (Sweden)

    Ali H Hassan

    2010-10-01

    Full Text Available Ali H Hassan11Department of Preventive Dental Sciences, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi ArabiaObjective: To evaluate the current pattern of third molar impaction in a sample of Saudi patients.Methods: One thousand thirty-nine orthopantomograms (OPG of patients ranging in age from 19 to 46 years (536 males and 503 females were evaluated to determine the frequency of impacted third molars, their levels of eruption, and their angulations.Results: Four hundred twenty-two (40.5% of the 1039 OPG showed at least one impacted third molar, with no significant difference between males (222; 52.6% and females (200; 47.4% (P = 0.284. The most common number of impacted third molars per OPG was one (72.5%. Impacted third molars were 1.64 times more likely to occur in the mandible than in the maxilla. The most common angulation of impaction in the mandible was the mesial (33.4%, while the most common angulation in the maxilla, was the vertical (49.6%. Level B impaction was the most common in both maxilla (48.2% and mandible (67.7%. There was no significant difference in the frequency of impaction between the right and left sides in both jaws.Conclusion: The pattern of third molar impaction in the western region of Saudi Arabia is characterized by a high prevalence of impaction that is greater in the mandibles and with no sex predilection.Keywords: third molar, impaction, prevalence, Saudi 

  4. A new partial SOI-LDMOSFET with a modified buried oxide layer for improving self-heating and breakdown voltage

    International Nuclear Information System (INIS)

    Jamali Mahabadi, S E; Orouji, Ali A; Keshavarzi, P; Moghadam, Hamid Amini

    2011-01-01

    In this paper, for the first time, we propose a partial silicon-on-insulator (P-SOI) lateral double-diffused metal-oxide-semiconductor-field-effect-transistor (LDMOSFET) with a modified buried layer in order to improve breakdown voltage (BV) and self-heating effects (SHEs). The main idea of this work is to control the electric field by shaping the buried layer. With two steps introduced in the buried layer, the electric field distribution is modified. Also a P-type window introduced makes the substrate share the vertical voltage drop, leading to a high vertical BV. Moreover, four interface electric field peaks are introduced by the buried P-layer, the Si window and two steps, which modulate the electric field in the SOI layer and the substrate. Hence, a more uniform electric field is obtained; consequently, a high BV is achieved. Furthermore, the Si window creates a conduction path between the active layer and substrate and alleviates the SHE. Two-dimensional simulations show that the BV of double step partial silicon on insulator is nearly 69% higher and alleviates SHEs 17% in comparison with its single step partial SOI counterpart and nearly 265% higher and alleviate SHEs 18% in comparison with its conventional SOI counterpart

  5. Partially ionized gas flow and heat transfer in the separation, reattachment, and redevelopment regions downstream of an abrupt circular channel expansion.

    Science.gov (United States)

    Back, L. H.; Massier, P. F.; Roschke, E. J.

    1972-01-01

    Heat transfer and pressure measurements obtained in the separation, reattachment, and redevelopment regions along a tube and nozzle located downstream of an abrupt channel expansion are presented for a very high enthalpy flow of argon. The ionization energy fraction extended up to 0.6 at the tube inlet just downstream of the arc heater. Reattachment resulted from the growth of an instability in the vortex sheet-like shear layer between the central jet that discharged into the tube and the reverse flow along the wall at the lower Reynolds numbers, as indicated by water flow visualization studies which were found to dynamically model the high-temperature gas flow. A reasonably good prediction of the heat transfer in the reattachment region where the highest heat transfer occurred and in the redevelopment region downstream can be made by using existing laminar boundary layer theory for a partially ionized gas. In the experiments as much as 90 per cent of the inlet energy was lost by heat transfer to the tube and the nozzle wall.

  6. Results of the mock-up experiment on partial LOCA

    International Nuclear Information System (INIS)

    Dreier, J.; Winkler, H.

    1985-01-01

    A mockup experiment has been performed to verify the heat transfer model for a partial loss of coolant accident in the swimming pool reactor SAPHIR. Three coolant channels with the same dimensions as in a SAPHIR fuel element were simulated using four electrically heated plates. For a water level such that the heated plates are partially submerged, plate temperatures remain below 160 deg. C for plate powers of up to 650 W. For water levels low enough to just block the channels, plate temperatures of 400 deg. C are reached for plate powers as low as 60 W. Details of the experiment and further results are discussed. (author)

  7. High intensity heat pulse problem

    International Nuclear Information System (INIS)

    Yalamanchili, R.

    1977-01-01

    The use of finite-difference methods for the solution of partial differential equations is common in both design and research and development because of the advance of computers. The numerical methods for the unsteady heat diffusion equation received most attention not only because of heat transfer problems but also happened to be the basis for any study of parabolic partial differential equations. It is common to test the heat equation first even the methods developed for complex nonlinear parabolic partial differential equations arising in fluid mechanics or convective heat transfer. It is concluded that the finite-element method is conservative in both stability and monoscillation characteristics than the finite-difference method but not as conservative as the method of weighted-residuals. Since the finite-element is unique because of Gurtin's variational principle and numerous finite-differences can be constructed, it is found that some finite-difference schemes are better than the finite-element scheme in accuracy also. Therefore, further attention is focused here on finite-difference schemes only. Various physical problems are considered in the field of heat transfer. These include: numerous problems in steady and unsteady heat conduction; heat pulse problems, such as, plasma torch; problems arising from machining operations, such as, abrasive cut-off and surface grinding. (Auth.)

  8. Cementoblastoma Relating to Right Mandibular Second Primary Molar

    Directory of Open Access Journals (Sweden)

    Sivakumar Nuvvula

    2016-01-01

    Full Text Available Cementoblastoma is a benign lesion of the odontogenic ectomesenchymal origin. It rarely occurs in primary dentition. This report describes a case of a cementoblastoma relating to the right mandibular second primary molar in a 7-year-old girl. Her panoramic radiograph revealed a well-defined radiopaque lesion with a radiolucent border extending from the distal surface of the mandibular right first primary molar to the distal surface of mandibular second primary molar. The tumor was attached to the mesial root of primary second molar and was excised along with the teeth involved and sent for histopathological evaluation, which showed irregular trabeculae of mineralized tissue interspersed with fibrovascular connective tissue, trabeculae of mineralized tissue with prominent reversal lines, and peripheral rimming of the mineralized tissue with blast cells. On a six-month follow-up, there has been no recurrence of the lesion.

  9. Experimental and predicted data of excess molar enthalpies and excess molar volumes for the ternary system (1,3-dichlorobenzene + benzene + 1-chlorohexane) at T = 298.15 K

    International Nuclear Information System (INIS)

    Mato, Marta M.; Verdes, Pedro V.; Paz Andrade, M.I.; Legido, José Luis

    2014-01-01

    Graphical abstract: - Highlights: • Experimental enthalpy and densitiy for the mixture 1,3-dichlorobenzene + benzene + 1-chlorohexane were measured. • The excess molar volumes were calculated from the densities of the pure liquids and their mixtures. • The Cibulka equation was used to correlate the ternary contribution of the excess molar properties. • The experimental data were used to test several empirical equations. - Abstract: Experimental excess molar enthalpies, densities and excess molar volumes for the ternary system {x 1 1,3-dichlorobenzene + x 2 benzene + (1 − x 1 − x 2 ) 1-chlorohexane} have been determined at the temperature of 298.15 K and atmospheric pressure. Values of excess molar enthalpies were measured using a Calvet microcalorimeter, and excess molar volumes were determined from the densities of the pure liquids and mixtures, using a vibrating-tube densimeter. The results were fitted by means of different variable degree polynomials. Smooth representations of the results are presented and used to construct constant contours of excess molar enthalpy and excess molar volume on Roozeboom diagrams. Several empirical expressions that have been suggested for use with parameters and predicting excess properties of ternary mixtures from the experimental binary data were tested

  10. Genetic integration of molar cusp size variation in baboons.

    Science.gov (United States)

    Koh, Christina; Bates, Elizabeth; Broughton, Elizabeth; Do, Nicholas T; Fletcher, Zachary; Mahaney, Michael C; Hlusko, Leslea J

    2010-06-01

    Many studies of primate diversity and evolution rely on dental morphology for insight into diet, behavior, and phylogenetic relationships. Consequently, variation in molar cusp size has increasingly become a phenotype of interest. In 2007 we published a quantitative genetic analysis of mandibular molar cusp size variation in baboons. Those results provided more questions than answers, as the pattern of genetic integration did not fit predictions from odontogenesis. To follow up, we expanded our study to include data from the maxillary molar cusps. Here we report on these later analyses, as well as inter-arch comparisons with the mandibular data. We analyzed variation in two-dimensional maxillary molar cusp size using data collected from a captive pedigreed breeding colony of baboons, Papio hamadryas, housed at the Southwest National Primate Research Center. These analyses show that variation in maxillary molar cusp size is heritable and sexually dimorphic. We also estimated additive genetic correlations between cusps on the same crown, homologous cusps along the tooth row, and maxillary and mandibular cusps. The pattern for maxillary molars yields genetic correlations of one between the paracone-metacone and protocone-hypocone. Bivariate analyses of cuspal homologues on adjacent teeth yield correlations that are high or not significantly different from one. Between dental arcades, the nonoccluding cusps consistently yield high genetic correlations, especially the metaconid-paracone and metaconid-metacone. This pattern of genetic correlation does not immediately accord with the pattern of development and/or calcification, however these results do follow predictions that can be made from the evolutionary history of the tribosphenic molar. Copyright 2009 Wiley-Liss, Inc.

  11. Autologous Platelet-rich Plasma after Third Molar Surgery.

    Science.gov (United States)

    Gandevivala, Adil; Sangle, Amit; Shah, Dinesh; Tejnani, Avneesh; Sayyed, Aatif; Khutwad, Gaurav; Patel, Arpit Arunbhai

    2017-01-01

    The aim of this study is to compare the efficacy of autologous platelet-rich plasma (PRP) in the third molar impactions, with respect to: pain, swelling, healing, and periodontal status distal to the second molar in patients who need surgical removal of bilateral impacted mandibular third molars. Twenty-five patients of both sexes aged between 16 and 60 years who required bilateral surgical removal of their impacted third molars and met the inclusion criteria were included in the study. After surgical extraction of the third molar, primary closure was performed in the control group, whereas PRP was placed in the socket followed by primary closure in the case group. The outcome variables were pain, swelling, wound healing, and periodontal probe depth that were follow-up period of 2 months. Quantitative data are presented as mean. Statistical significance was checked by t -test. There was a difference in the pain (0.071) and facial swelling (0.184), reduction between test and control on day 3, but it was not found to be significant. Periodontal pocket depth (0.001) and wound healing (0.001) less in case group compared with the control group was found to be significant. The use of PRP lessens the severity of immediate postoperative sequelae and decreases preoperative pocket depth.

  12. Changes in heart rate during third molar surgery

    NARCIS (Netherlands)

    Hollander, M. H. J.; Schortinghuis, J.; Vissink, A.

    2016-01-01

    Anxiety is an undesirable psychological phenomenon. Patients are usually anxious when subjected to third molar surgery, but the pattern of anxiety is unknown. The aim of this study was to assess the intensity and course of anxiety during third molar surgery. This study included 48 consecutive

  13. Unusal canal configuration in maxillary and mandibular second molars

    Directory of Open Access Journals (Sweden)

    Ramachandran Ragunathan

    2016-01-01

    Full Text Available This clinical article describes three different case reports of maxillary and mandibular second molars with the unusual anatomy of single root with a single canal and their endodontic management. An unusual case of bilateralism is observed in the first two cases in the form of single-rooted second mandibular molars in both the quadrant of the same patient. The presence of maxillary second molar with single root and single canal in the third case is unusual.

  14. Three-dimensional space changes after premature loss of a maxillary primary first molar.

    Science.gov (United States)

    Park, Kitae; Jung, Da-Woon; Kim, Ji-Yeon

    2009-11-01

    A space maintainer is generally preferred when a primary first molar is lost before or during active eruption of the first permanent molars in order to prevent space loss. However, controversy prevails regarding the space loss after eruption of the permanent first molars. The purpose of this study was to examine spatial changes subsequent to premature loss of a maxillary primary first molar after the eruption of the permanent first molars. Thirteen children, five girls and eight boys, expecting premature extraction of a maxillary primary first molar because of caries and/or failed pulp therapy, were selected. Spatial changes were investigated using a three-dimensional laser scanner by comparing the primary molar space, arch width, arch length, and arch perimeter before and after the extraction of a maxillary primary first molar. Also, the inclination and angulation changes in the maxillary primary canines, primary second molars, and permanent first molars adjacent to the extraction site were investigated before and after the extraction of the maxillary primary first molar in order to examine the source of space loss. There was no statistically significant space loss on the extraction side compared to the control side (P = 0.33). No consistent findings were seen on the inclination and angulation changes on the extraction side. The premature loss of a maxillary primary first molar, in cases with class I molar relationship, has limited influence on the space in permanent dentition.

  15. Fracture behavior of human molars.

    Science.gov (United States)

    Keown, Amanda J; Lee, James J-W; Bush, Mark B

    2012-12-01

    Despite the durability of human teeth, which are able to withstand repeated loading while maintaining form and function, they are still susceptible to fracture. We focus here on longitudinal fracture in molar teeth-channel-like cracks that run along the enamel sidewall of the tooth between the gum line (cemento-enamel junction-CEJ) and the occlusal surface. Such fractures can often be painful and necessitate costly restorative work. The following study describes fracture experiments made on molar teeth of humans in which the molars are placed under axial compressive load using a hard indenting plate in order to induce longitudinal cracks in the enamel. Observed damage modes include fractures originating in the occlusal region ('radial-median cracks') and fractures emanating from the margin of the enamel in the region of the CEJ ('margin cracks'), as well as 'spalling' of enamel (the linking of longitudinal cracks). The loading conditions that govern fracture behavior in enamel are reported and observations made of the evolution of fracture as the load is increased. Relatively low loads were required to induce observable crack initiation-approximately 100 N for radial-median cracks and 200 N for margin cracks-both of which are less than the reported maximum biting force on a single molar tooth of several hundred Newtons. Unstable crack growth was observed to take place soon after and occurred at loads lower than those calculated by the current fracture models. Multiple cracks were observed on a single cusp, their interactions influencing crack growth behavior. The majority of the teeth tested in this study were noted to exhibit margin cracks prior to compression testing, which were apparently formed during the functional lifetime of the tooth. Such teeth were still able to withstand additional loading prior to catastrophic fracture, highlighting the remarkable damage containment capabilities of the natural tooth structure.

  16. Ruptured tubal molar pregnancy

    African Journals Online (AJOL)

    2011-05-19

    May 19, 2011 ... In most instances, moles develop within the uterine cavity, but may occur at ... Patients with tubal molar pregnancy are very difficult to distinguish .... There was a left-sided adnexal mass, whose size could not be appreciated ...

  17. Taurodont molars: Review of literature and radiological features

    International Nuclear Information System (INIS)

    Saini, T.; Wilson, C. A.

    1990-01-01

    Taurodontic molar teeth are present as a clinical entity in modem man. This is a suggestion that the occurrence has a racial bias. The importance of the differential diagnosis of teeth with enlarged pulp is discussed, and the possible influence of taurodontic molars on treatment planning is outlined. (author)

  18. Excess molar volumes and isentropic compressibilities of binary

    Indian Academy of Sciences (India)

    Excess molar volumes (E) and deviation in isentropic compressibilities (s) have been investigated from the density and speed of sound measurements of six binary liquid mixtures containing -alkanes over the entire range of composition at 298.15 K. Excess molar volume exhibits inversion in sign in one binary ...

  19. Vaporization study on vanadium-oxygen solid solution by mass spectrometric method

    International Nuclear Information System (INIS)

    Banchorndhevakul, W.; Matsui, Tsuneo; Naito, Keiji

    1986-01-01

    The vapor pressures over vanadium-oxygen solid solution (0.001 ≤ O/V ≤ 0.145) were measured by mass-spectrometric method in the temperature range of 1,855 ∼ 2,117 K. The main vapor species were observed to be V(g) and VO(g). The vapor pressure of V(g) is higher than that of VO(g) over the solid solutions with all O/V ratios except for O/V = 0.145. The vapor pressure of V(g) is nearly independent of O/V ratio. The vapor pressure of VO(g) decreases with decreasing O/V ratio. The oxygen partial pressure was calculated as a function of temperature and O/V ratio from the vapor pressures of V(g) and VO(g), from which the partial molar enthalpy and entropy of oxygen in the solid solution were determined. The partial molar enthalpy of oxygen was observed to be independent of composition, suggesting the presence of very weak interaction between interstitial oxygens. The compositional dependence of the partial molar entropy of oxygen can be explained by assuming the occupation of the octahedral site in bcc vanadium lattice by the interstitial oxygens. The excess partial molar entropy of oxygen was compared with the value derived from the sum of the contributions from the volume expansion, electronic heat capacity and vibrational terms. (author)

  20. Radiographic evaluation of third molar development in 6 to 24 year olds

    International Nuclear Information System (INIS)

    Jung, Yun Hwa; Cho, Bong Hae

    2014-01-01

    This study investigated the developmental stages of third molars in relation to chronological age and compared third molar development according to location and gender. A retrospective analysis of panoramic radiographs of 2490 patients aged between 6 and 24 years was conducted, and the developmental stages of the third molars were evaluated using the modified Demirjian's classification. The mean age, standard deviation, minimal and maximal age, and percentile distributions were recorded for each stage of development. A Mann-Whitney U test was performed to test the developmental differences in the third molars between the maxillary and mandibular arches and between genders. A linear regression analysis was used for assessing the correlation between the third molar development and chronological age. The developmental stages of the third molars were more advanced in the maxillary arch than the mandibular arch. Males reached the developmental stages earlier than females. The average age of the initial mineralization of the third molars was 8.57 years, and the average age at apex closure was 21.96 years. The mean age of crown completion was 14.52 and 15.04 years for the maxillary and the mandibular third molars, respectively. The developmental stages of the third molars clearly showed a strong correlation with age. The third molars developed earlier in the upper arch than the lower arch; further, they developed earlier in males than in females.

  1. Partial differential equations for scientists and engineers

    CERN Document Server

    Farlow, Stanley J

    1993-01-01

    Most physical phenomena, whether in the domain of fluid dynamics, electricity, magnetism, mechanics, optics, or heat flow, can be described in general by partial differential equations. Indeed, such equations are crucial to mathematical physics. Although simplifications can be made that reduce these equations to ordinary differential equations, nevertheless the complete description of physical systems resides in the general area of partial differential equations.This highly useful text shows the reader how to formulate a partial differential equation from the physical problem (constructing th

  2. Prevention of alveolar osteitis after third molar surgery: Comparative ...

    African Journals Online (AJOL)

    Prevention of alveolar osteitis after third molar surgery: Comparative study of the ... for surgical extraction of lower third molar were prospectively, consecutively, and ... Information on demographic, types and level of impaction, indications for ...

  3. A study of the eruption of the mandibular first permanent molar

    OpenAIRE

    河野, 美砂子; Kohno, Misako

    1995-01-01

    The object of this study was to know what positional changes of the mandibular first permanent molars occur just before their gingival emergence. The eruptive process of the mandibular first molars was investigated during the period from alveolareruption to preoraleruption. The subjects were 14 patients whose second primary molars were prematurely lost in one side and remained on the other side. Longitudinal oblique cephalograms were used to estimate the eruptive process of the first molars o...

  4. Classical fluids of negative heat capacity

    Energy Technology Data Exchange (ETDEWEB)

    Landsberg, P.T. [Southampton Univ., (United Kingdom). Faculty of Mathematical Studies; Woodard, R.P. [Florida Univ., Gainesville, FL (United States). Dept. of Physics

    1992-06-01

    It is shown that new parameters X can be defined such that the heat capacity C{sub X} {equivalent_to} T({partial_derivative}S/{partial_derivative}T)X is negative, even when the canonical ensemble (i.e. at fixed T = ({partial_derivative}U/{partial_derivative}S) and Y {ne} X) is stable. As examples we treat black body radiation and general gas systems with nonsingular {kappa}{sub T}. For the case of a simple ideal gas we even exhibit an apparatus which enforces a constraint X(p,V) = const. that makes C{sub X} < 0. Since it is possible to invent constraints for which canonically stable systems have negative heat capacity we speculate that it may also be possible to infer the statistical mechanics of canonically unstable systems - for which even the traditional heat capacities are negative - by imposing constraints that stabilize the associated, inoncanonical ensembles.

  5. Classical fluids of negative heat capacity

    Energy Technology Data Exchange (ETDEWEB)

    Landsberg, P.T. (Southampton Univ., (United Kingdom). Faculty of Mathematical Studies); Woodard, R.P. (Florida Univ., Gainesville, FL (United States). Dept. of Physics)

    1992-06-01

    It is shown that new parameters X can be defined such that the heat capacity C{sub X} {equivalent to} T({partial derivative}S/{partial derivative}T)X is negative, even when the canonical ensemble (i.e. at fixed T = ({partial derivative}U/{partial derivative}S) and Y {ne} X) is stable. As examples we treat black body radiation and general gas systems with nonsingular {kappa}{sub T}. For the case of a simple ideal gas we even exhibit an apparatus which enforces a constraint X(p,V) = const. that makes C{sub X} < 0. Since it is possible to invent constraints for which canonically stable systems have negative heat capacity we speculate that it may also be possible to infer the statistical mechanics of canonically unstable systems - for which even the traditional heat capacities are negative - by imposing constraints that stabilize the associated, inoncanonical ensembles.

  6. Double versus single cartridge of 4% articaine infiltration into the retro-molar area for lower third molar surgery.

    Science.gov (United States)

    Sawang, Kamonpun; Chaiyasamut, Teeranut; Kiattavornchareon, Sirichai; Pairuchvej, Verasak; Bhattarai, Bishwa Prakash; Wongsirichat, Natthamet

    2017-06-01

    There are no studies regarding 4% articaine infiltration injection into the retro-molar area for an impacted lower third molar (LITM) surgery. This study aimed to evaluate the efficacy of infiltration using 1.7 ml (single cartridge: SC) of 4% articaine versus 3.4 ml (double cartridges: DC) of 4% articaine with 1:100,000 epinephrine in LITM surgery. This study involved 30 healthy patients with symmetrical LITM. The patients were assigned to receive either a DC or SC of 4% articaine with 1:100,000 epinephrine as a local anesthetic for each operation. Onset, duration, profoundness, need for additional anesthetic administration, total volume of anesthetic used, vitality of the tooth, and pain score during operation were recorded. The DC of 4 % articaine had a significantly higher success rate (83.3%) than did the SC (53.3%; P molar region can be an alternative anesthetic for LITM surgery.

  7. Excess molar enthalpies for binary mixtures of different amines with water

    International Nuclear Information System (INIS)

    Zhang, Ruilei; Chen, Jian; Mi, Jianguo

    2015-01-01

    Highlights: • Isothermal excess molar enthalpies for binary mixtures of different amines with water. • The Redlich–Kister equation and the NRTL model was used to fit the experimental data. • The excess molar enthalpies were discussed with different structures of amines. - Abstract: The isothermal excess molar enthalpies for binary mixtures of different amines with water were measured with a C-80 Setaram calorimeter. The experimental results indicate that the excess molar enthalpy is related to the molecular structure. The experimental excess molar enthalpies were satisfactorily fitted with the Redlich–Kister equation. They were also used to test the suitability of the NRTL model, and the deviations are a little larger than the R–K equation

  8. Root canal morphology of primary molars: a micro-computed tomography study.

    Science.gov (United States)

    Fumes, A C; Sousa-Neto, M D; Leoni, G B; Versiani, M A; da Silva, L A B; da Silva, R A B; Consolaro, A

    2014-10-01

    This was to investigate the root canal morphology of primary molar teeth using micro-computed tomography. Primary maxillary (n = 20) and mandibular (n = 20) molars were scanned at a resolution of 16.7 μm and analysed regarding the number, location, volume, area, structured model index (SMI), area, roundness, diameters, and length of canals, as well as the thickness of dentine in the apical third. Data were statistically compared by using paired-sample t test, independent sample t test, and one-way analysis of variance with significance level set as 5%. Overall, no statistical differences were found between the canals with respect to length, SMI, dentine thickness, area, roundness, and diameter (p > 0.05). A double canal system was observed in the mesial and mesio-buccal roots of the mandibular and maxillary molars, respectively. The thickness in the internal aspect of the roots was lower than in the external aspect. Cross-sectional evaluation of the roots in the apical third showed flat-shaped canals in the mandibular molars and ribbon- and oval-shaped canals in the maxillary molars. External and internal anatomy of the primary first molars closely resemble the primary second molars. The reported data may help clinicians to obtain a thorough understanding of the morphological variations of root canals in primary molars to overcome problems related to shaping and cleaning procedures, allowing appropriate management strategies for root canal treatment.

  9. Apparent molar volumes and compressibilities of selected electrolytes in dimethylsulfoxide

    International Nuclear Information System (INIS)

    Warminska, Dorota; Grzybkowski, Waclaw

    2010-01-01

    Densities at T = (293.15, 298.15, 303.15, 313.15, 323.15, and 333.15) K and sound velocities at T = 298.15 K of tetraphenylphosphonium bromide, sodium tetraphenylborate, sodium bromide, and sodium perchlorate in dimethylsulfoxide have been measured over the composition range from (0 to 0.3) mol . kg -1 . From these data, apparent molar volumes and apparent molar isentropic compressibilities at infinite dilution as well as the expansibilities have been evaluated. The results have been discussed in terms of employing tetraphenylphosphonium tetraphenylborate as a reference electrolyte in splitting the limiting apparent molar volumes and apparent molar isentropic compressibilities into ionic contributions.

  10. Radiographic evaluation of third molar development in 6- to 24-year-olds

    Science.gov (United States)

    Jung, Yun-Hoa

    2014-01-01

    Purpose This study investigated the developmental stages of third molars in relation to chronological age and compared third molar development according to location and gender. Materials and Methods A retrospective analysis of panoramic radiographs of 2490 patients aged between 6 and 24 years was conducted, and the developmental stages of the third molars were evaluated using the modified Demirjian's classification. The mean age, standard deviation, minimal and maximal age, and percentile distributions were recorded for each stage of development. A Mann-Whitney U test was performed to test the developmental differences in the third molars between the maxillary and mandibular arches and between genders. A linear regression analysis was used for assessing the correlation between the third molar development and chronological age. Results The developmental stages of the third molars were more advanced in the maxillary arch than the mandibular arch. Males reached the developmental stages earlier than females. The average age of the initial mineralization of the third molars was 8.57 years, and the average age at apex closure was 21.96 years. The mean age of crown completion was 14.52 and 15.04 years for the maxillary and the mandibular third molars, respectively. Conclusion The developmental stages of the third molars clearly showed a strong correlation with age. The third molars developed earlier in the upper arch than the lower arch; further, they developed earlier in males than in females. PMID:25279338

  11. The origin of the lower fourth molar in canids, inferred by individual variation

    Directory of Open Access Journals (Sweden)

    Masakazu Asahara

    2016-11-01

    Full Text Available Background An increase in tooth number is an exception during mammalian evolution. The acquisition of the lower fourth molar in the bat-eared fox (Otocyon megalotis, Canidae, Carnivora, Mammalia is one example; however, its developmental origin is not clear. In some canids (Canidae, individual variation exist as supernumerary molar M4. This study focuses on the acquisition of the lower fourth molar in canids and proposes that the inhibitory cascade model can explain its origin. Methods Occlusal view projected area of lower molars was determined from 740 mandibles obtained from Canis latrans, Nyctereutes procyonoides, and Urocyon cinereoargenteus museum specimens. For each molar, relative sizes of molars (M2/M1 and M3/M1 scores affected by inhibition/activation dynamics during development, were compared between individuals with and without supernumerary molar (M4. Results Possession of a supernumerary molar was associated with significantly larger M2/M1 score in Canis latrans, M3/M1 score in Nyctereutes procyonoides, and M2/M1 and M3/M1 scores in Urocyon cinereoargenteus compared to individuals of these species that lacked supernumerary molars. Discussion We propose that, in canids, the supernumerary fourth molar is attributable to reduced inhibition and greater activation during molar development. In the bat-eared fox, altered inhibition and activation dynamics of dental development during omnivorous-insectivorous adaptation may be a contributing factor in the origin of the lower fourth molar.

  12. Morphometric variation of extant platyrrhine molars: taxonomic implications for fossil platyrrhines

    Directory of Open Access Journals (Sweden)

    Mónica Nova Delgado

    2016-05-01

    Full Text Available The phylogenetic position of many fossil platyrrhines with respect to extant ones is not yet clear. Two main hypotheses have been proposed: the layered or successive radiations hypothesis suggests that Patagonian fossils are Middle Miocene stem platyrrhines lacking modern descendants, whereas the long lineage hypothesis argues for an evolutionary continuity of all fossil platyrrhines with the extant ones. Our geometric morphometric analysis of a 15 landmark-based configuration of platyrrhines’ first and second lower molars suggest that morphological stasis may explain the reduced molar shape variation observed. Platyrrhine lower molar shape might be a primitive retention of the ancestral state affected by strong ecological constraints throughout the radiation of the main platyrrhine families. The Patagonian fossil specimens showed two distinct morphological patterns of lower molars, Callicebus—like and Saguinus—like, which might be the precursors of the extant forms, whereas the Middle Miocene specimens, though showing morphological resemblances with the Patagonian fossils, also displayed new, derived molar patterns, Alouatta—like and Pitheciinae—like, thereby suggesting that despite the overall morphological stasis of molars, phenotypic diversification of molar shape was already settled during the Middle Miocene.

  13. Detection of Mesiobuccal Canal in Maxillary Molars and Distolingual Canal in Mandibular Molars by Dental CT: A Retrospective Study of 100 Cases

    Directory of Open Access Journals (Sweden)

    Sushma Rathi

    2010-01-01

    Full Text Available Objective. To detect presence of MB2 canal in maxillary molars and distolingual canal in mandibular molars by Dental CT. Material and Methods. A retrospective study of 100 Dental CTs was done. Axial and paraxial images obtained were used to assess the presence of MB2 canal in maxillary molars and distolingual canal in mandibular molars. Results. The youngest patient was of 11 years while the eldest patient was of 77 years. Males were 58 in number and females were 42 in number. MB2 canals were present in 57 patients and distolingual canal was present in 18 patients. Maximum MB2 canals were present in age group between 51 and 60 years, while distolingual canals were present in age group of 21–30 years. Conclusion. Dental CT allows adequate visualization of variation in root canal morphology and can be important diagnostic tool for successful endodontic therapy.

  14. Influence of Implant Position on Stress Distribution in Implant-Assisted Distal Extension Removable Partial Dentures: A 3D Finite Element Analysis.

    Directory of Open Access Journals (Sweden)

    Yeganeh Memari

    2014-10-01

    Full Text Available Distal extension removable partial denture is a prosthesis with lack of distal dental support with a 13-fold difference in resiliency between the mucosa and the periodontal ligament, resulting in leverage during compression forces. It may be potentially destructive to the abutments and the surrounding tissues. The aim of this study was to assess the effect of implant location on stress distribution, in distal extension implant assisted removable partial dentures.Three-dimensional models of a bilateral distal extension partially edentulous mandible containing anterior teeth and first premolar in both sides of the arch, a partial removable denture and an implant (4×10mm were designed. With the aid of the finite element program ANSYS 8.0, the models were meshed and strictly vertical forces of 10 N were applied to each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.When an implant was placed in the second premolar region, the highest stress on implant, abutment tooth and cancellous bone was shown. The lowest stress was shown on implant and bone in the 1(st molar area.Implants located in the first molar area showed the least distribution of stresses in the analyzed models.

  15. Orthodontic space closure after first molar extraction without skeletal anchorage.

    Science.gov (United States)

    Jacobs, Collin; Jacobs-Müller, Claudia; Luley, Carolin; Erbe, Christina; Wehrbein, Heiner

    2011-03-01

    The aim of the study was an analysis of effects and side-effects during mesialization of second molars after extraction of the first permanent molars using the anterior dentition/premolars (PM) as an anchorage unit. A total of 35 patients were examined retrospectively who had undergone unilateral or bilateral first permanent molar extraction in the upper or lower arch due to carious lesions. Space closure was carried out in all cases through mesialization of the second molar using an elastic chain fixed to an edgewise stainless steel archwire and tying the anterior dentition/PM together with a continuous laceback ligature. Tooth movement was assessed from lateral cephalograms, orthopantomograms (OPGs) and images of the patient's study casts taken before and after the end of therapy. Space closure after first molar extractions by mesialization of the second molars without skeletal anchorage was largely achieved by bodily forward movement of the teeth, including a small tipping component or tooth-uprighting component when molars were already mesially inclined. Unilateral and bilateral mesialization of the second molars led to retrusion in the maxilla and mandible [(∆incl.=-3.6° (max., bil.), ∆incl.=-4.2° (mand., bil.)] and to translational retraction [(∆s=-2.3 mm (max., bil.), ∆s=-1.6 mm (mand., bil.)] of the incisors. Examination of the soft tissues revealed an increased posterior displacement of the upper and lower lips to the esthetic line [(∆s=-2.8 mm (max. bil.), ∆s=-2.2 mm (mand., bil.)]. In cases of unilateral mesialization less than 50% of the patients had a slight midline deviation in the mandible towards the extraction side. Side effects during mesialization of the second molars without skeletal anchorage in the anterior dentition/PM were observed primarily affecting the incisors integrated into the anterior anchorage unit. These side-effects resulted in posterior displacement of the soft tissues, including a change in profile. This must be

  16. Improved method to determine the molar volume and compositions of the NaCl-H2O-CO2 system inclusion

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    On the basis of Parry’s method (1986), an improved method was established to determine the molar volume (Vm) and compositions (X) of the NaCl-H2O-CO2 (NHC) system inclusion. To use this method, the determination of Vm-X only requires three microthermometric data of a NHC inclusion: partial homog-enization temperature (Th ,CO2), salinity (S) and total homogenization temperature (Th). Theoretically, four associated equations are needed containing four unknown parameters: X CO2, XNaCl, Vm and F (volume fraction of CO2 phase in total inclusion when occurring partial homogenization). When they are released, the Vm-X are determined. The former three equations, only correlated with Th ,CO2, S and F, have simplified expressions:XCO2=f1(Th,CO2,S,F),XNaCl=f2(Th,CO2,S,F),Vm=f3(Th,CO2,S,F). The last one is the thermodynamic relationship of X CO2, XNaCl, Vm and Th:f4(XCO2,XNaCl,Vm,Th)=0.Since the above four associated equations are complicated, it is necessary to adopt iterative technique to release them. The technique can be described by:(i) Freely input a F value (0≤F≤1),with Th ,CO2 and S, into the former three equations. As a result,X CO 2,XNaCl and the molar volume value recorded as Vm1 are derived. (ii) Input the X CO2 and XNaCl gotten in the step above into the last equation, and another molar volume value recorded as Vm2 is determined. (iii) If Vm1 is unequal to Vm2, the calculation will be restarted from “(i)”. The iteration is completed until Vm1 is equal to Vm2, which means that the four associated equations are released. Compared to Parry’s (1986) solution method, the improved method is more convenient to use, as well as more accurate to determine X CO 2. It is available for a NHC inlusion whose partial homogenization temperature is higher than clatherate melting temperature and there are no solid salt crystals in the inclusion at parital homogenization.

  17. Improved method to determine the molar volume and compositions of the NaCl-H2O-CO2 system inclusion

    Institute of Scientific and Technical Information of China (English)

    SONG YuCai; HU WenXuan; NI Pei; DUAN ZhenHao; ZHANG XueFeng

    2007-01-01

    On the basis of Parry's method (1986),an improved method was established to determine the molar volume(Vm)and compositions(X)of the NaCl-H2O-CO2(NHC)system inclusion.To use this method,the determination of Vm-X only requires three microthermometric data of a NHC inclusion:partial homogenization temperature(Th,CO2),salinity(s)and total homogenization temperature(Th).Theoretically,four associated equations are needed containing four unknown parameters:Xco2,XNcl,Vm and F (volume fraction of CO2 phase in total inclusion when occurring partial homogenization).When they are released,the Vm-X are determined.The former three equations,only correlated with Th,co2,S and F,have simplified expressions:XCO2=f1(Th,CO2,S,F),XNaCl=f2(Th,CO2,S,F),Vm=f3(Th,CO2,S,F).The last one is the thermodynamic relationship of Xco2,Xnacl,vm and Th:f4(XCO2,XNacl,Vm,Th)=0. Since the above four associated equations are complicated,it is necessary to adopt iterative technique to release them.The technique can be described by:(i)Freely input a F value(0≤F≤1),with Th,co2 and S,into the former three equations.As a result,Xco2,XNacl and the molar volume value recorded as Vm1 are derived.(ii)Input the Xco2 and XNacl gotten in the step above into the last equation,and another molar volume value recorded as Vm2 is determined.(iii) If Vm1 is unequal to Vm2,the calculation will be restarted from"(i)".The iteration is completed until Vm1 is equal to Vm2,which means that the four associated equations are released.Compared to Parry's (1986) solution method,the improved method is more convenient to use,as well as more accurate to determine Xco2.It is available for a NHC inlusion whose partial homogenization temperature is higher than clatherate melting temperature and there are no solid salt crystals in the inclusion at parital homogenization.

  18. Molar exergy and flow exergy of pure chemical fuels

    International Nuclear Information System (INIS)

    Zanchini, Enzo; Terlizzese, Tiziano

    2009-01-01

    Expressions of the molar exergy and of the molar flow exergy of a pure chemical fuel are deduced rigorously from the basic principles of thermodynamics. It is shown that molar exergy and molar flow exergy coincide when the temperature T and the pressure p of the fuel are equal to the temperature T B and the pressure p B of the environment; a general relation between exergy and flow exergy is proved as a consequence. The deduction of the expression of the molar exergy of a chemical fuel for non-standard values of T B and p B is clarified. For hydrogen, carbon dioxide and several hydrocarbons, tables are reported to allow a simple calculation of the molar exergy of the fuel for any value of the temperature T B and the relative humidity φ B of the environment, in the range 268.15 K ≤ T B ≤ 313.15 K and 0.1 ≤ φ B ≤ 1, with reference to the standard atmospheric pressure. Additional tables are provided to evaluate the difference between the exergy or the flow exergy of the fuel in its given initial state and the exergy at T = T B and p = p B . In these tables, it is assumed that fuel and environment have the same temperature and that the fuel pressure varies in the range 1.01325 bar ≤ p ≤ 200 bar; the fuel may be gas or liquid.

  19. Microleakage of different adhesive systems in primary molars ...

    African Journals Online (AJOL)

    Background and aim: This study aimed to examine the microleakage of class V cavities of primary molars prepared by either a conventional dental bur or Er:YAG laser and one of two different adhesive systems. Methods: A total of 50 tooth samples from primary molars were used in this study. They were randomly assigned ...

  20. Excess molar volume and viscosity deviation for binary mixtures of γ-butyrolactone with dimethyl sulfoxide

    International Nuclear Information System (INIS)

    Krakowiak, Joanna; Śmiechowski, Maciej

    2017-01-01

    Highlights: • Densities and viscosities of DMSO-GBL binary liquid mixtures were measured. • The volumetric parameters and excess quantities were obtained. • Ab initio calculations were performed for single molecules and dimers in the studied mixture. • The interactions in solutions are weaker than in pure solvents. - Abstract: The densities of binary liquid mixtures of dimethyl sulfoxide and γ-butyrolactone at (293.15, 298.15, 303.15 and 313.15) K and viscosity at T = 298.15 K have been measured at atmospheric pressure over the entire range of concentration. From these data the excess molar volumes V E at (293.15, 298.15, 303.15 and 313.15) K and the viscosity deviation, the excess entropy, and the excess Gibbs energy of activation for viscous flow at T = 298.15 K have been determined. These data were mathematically represented by the Redlich-Kister polynomial. Partial and apparent molar volumes have been calculated for better understanding of the interactions in the binary systems. The obtained data indicate the lack of specific interactions between unlike molecules, which seem to be a little weaker as compared to the interactions in pure solvents.

  1. Standard molar enthalpies of formation of monochloroacetophenone isomers

    International Nuclear Information System (INIS)

    Ribeiro da Silva, Manuel A.V.; Amaral, Luisa M.P.F.

    2010-01-01

    The standard (p 0 =0.1MPa) molar enthalpies of formation of the liquids 2'-, 3'-, and 4'-chloroacetophenones were derived from the standard molar energies of combustion, in oxygen, to yield CO 2 (g) and HCl . 600H 2 O(l), at T = 298.15 K, measured by rotating-bomb combustion calorimetry. The Calvet microcalorimetry was used to measure the enthalpies of vaporization of the three compounds. These two thermodynamic parameters yielded the standard molar enthalpies of formation of the chloroacetophenone isomers, in the gaseous phase, at T = 298.15 K. (table) An empirical scheme, developed by Cox, was used to estimate the gas-phase enthalpies of formation and the obtained values were compared with the experimental ones.

  2. Teaching Modeling with Partial Differential Equations: Several Successful Approaches

    Science.gov (United States)

    Myers, Joseph; Trubatch, David; Winkel, Brian

    2008-01-01

    We discuss the introduction and teaching of partial differential equations (heat and wave equations) via modeling physical phenomena, using a new approach that encompasses constructing difference equations and implementing these in a spreadsheet, numerically solving the partial differential equations using the numerical differential equation…

  3. Incisor and molar overjet, arch contraction, and molar relationship in the mixed dentition in repaired complete unilateral cleft lip and palate: A qualitative and quantitative appraisal.

    Science.gov (United States)

    Disthaporn, Suteeta; Suri, Sunjay; Ross, Bruce; Tompson, Bryan; Baena, Diogenes; Fisher, David; Lou, Wendy

    2017-07-01

    To compare the mixed dentition incisor and molar overjet, severity of contraction of the dental arch, and the sagittal molar relationship on the cleft side vs the noncleft side in children with repaired complete unilateral cleft of the lip and palate (UCLP). Orthodontic records taken prior to orthodontic preparation for alveolar bone grafting were screened to select study casts from patients with nonsyndromic repaired complete UCLP who did not have mandibular skeletal or dental asymmetry. The study sample comprised dental casts from 74 children aged 8.9 ± 1 years. Standardized digital photographs were acquired at 1:1 magnification. A coordinate system was developed using digital image-processing software (Photoshop CS4 and Adobe Illustrator). Incisor and molar overjet, Angle's classification, and arch contraction were recorded. Descriptive statistics, paired t-tests, and kappa statistics were used to compare the cleft and noncleft sides. A negative overjet of -1 to -5 mm was often present at the incisors, with greater frequency and magnitude on the cleft side. Class II molar relation was more frequent on the cleft side (61.1%) than on the noncleft side (47.2%). Significantly greater contraction of the cleft side deciduous canine and deciduous first molar was noted, while the difference was very minor at the first permanent molar. Cleft side maxillary arch contraction was most severe in the deciduous canine and first deciduous molar region and progressively less severe in the posterior region of the arch. A greater frequency and severity of negative overjet and Class II molar relationship was seen on the cleft side.

  4. Heat and mass transfer on a MHD third grade fluid with partial slip flow past an infinite vertical insulated porous plate in a porous medium

    International Nuclear Information System (INIS)

    Baoku, I.G.; Olajuwon, B.I.; Mustapha, A.O.

    2013-01-01

    Highlights: ► We model the flow of a MHD third grade fluid, heat and mass transfer in a porous medium with partial slip flow regime. ► We examine the effects of pertinent parameters on the velocity, temperature and species concentration distributions. ► The values momentum and thermal boundary layers increase with increasing third grade parameter β. ► The consequences of increasing the permeability parameter m and partial slip parameter λ give rise to fluid velocity. ► The magnetic field parameter H decreases the momentum boundary layer and increases the concentration boundary layer. -- Abstract: The influence of third grade, partial slip and other thermophysical parameters on the steady flow, heat and mass transfer of viscoelastic third grade fluid past an infinite vertical insulated plate subject to suction across the boundary layer has been investigated. The space occupying the fluid is porous. The momentum equation is characterized by a highly nonlinear boundary value problem in which the order of the differential equation exceeds the number of available boundary conditions. An efficient numerical scheme of midpoint technique with Richardson’s extrapolation is employed to solve the governing system of coupled nonlinear equations of momentum, energy and concentration. Numerical calculations were carried out for different values of various interesting non-dimensional quantities in the slip flow regime with heat and mass transfer and were shown with the aid of figures. The values of the wall shear stress, the local rate of heat and mass transfers were obtained and tabulated. The analysis shows that as the fluid becomes more shear thickening, the momentum boundary layer decreases but the thermal boundary layer increases; the magnetic field strength is found to decrease with an increasing temperature distribution when the porous plate is insulated. The consequences of increasing the permeability parameter and Schmidt number decrease both the momentum

  5. First molar cross-bite is more closely associated with a reverse chewing cycle than anterior or pre-molar cross-bite during mastication.

    Science.gov (United States)

    Tomonari, H; Ikemori, T; Kubota, T; Uehara, S; Miyawaki, S

    2014-12-01

    A posterior cross-bite is defined as an abnormal bucco-lingual relationship between opposing molars, pre-molars or both in centric occlusion. Although it has been reported that patients with unilateral posterior cross-bite often show unique chewing patterns, the relationship between the form of cross-bite and masticatory jaw movement remains unclear in adult patients. The objective of this study was to investigate masticatory jaw movement among different forms of cross-bite. One hundred and one adults were recruited in this study: 27 had unilateral first molar cross-bite (MC group); 28, unilateral pre-molar cross-bite (PC group); 23, anterior cross-bite (AC group); and 23, normal occlusion (control group). Masticatory jaw movement of the lower incisor point was recorded with six degrees of freedom jaw-tracking system during unilateral mastication. Our results showed that the reverse chewing ratio during deliberate unilateral mastication was significantly larger in the MC group than in the PA (P chewing cycle. © 2014 John Wiley & Sons Ltd.

  6. The molar hydrodynamic volume changes of factor VIIa due to GlycoPEGylation

    DEFF Research Database (Denmark)

    Plesner, Bitten; Westh, Peter; Hvidt, Søren

    2011-01-01

    The effects of GlycoPEGylation on the molar hydrodynamic volume of recombinant human rFVIIa were investigated using rFVIIa and two GlycoPEGylated recombinant human FVIIa derivatives, a linear 10 kDa PEG and a branched 40 kDa PEG, respectively. Molar hydrodynamic volumes were determined by capillary......, that the molar hydrodynamic volume of the conjugated protein is not just an addition of the molar hydrodynamic volume of the PEG and the protein. The molar hydrodynamic volume of the GlycoPEGylated protein is larger than the volume of its composites. These results suggest that both the linear and the branched...

  7. Method of nuclear power plant transition to partial loa

    International Nuclear Information System (INIS)

    Ilyunin, V.G.; Kuznetsov, I.A.; Murogov, V.M.; Shmelev, A.N.

    1977-01-01

    Five variants are proposed of a nuclear power plant with two reactors, of which one a breeder reactor, suitable for work under partial electrical load. Both reactors have a common secondary coolant circuit with a turbine, the breeder reactor operates at a lower coolant temperature in the primary coolant circuit than the other. In the transition of the power plant to the partial electrical load mode, the coolants of both reactors mix at a certain ratio. Heating of the turbine working medium is controlled so that the breeder reactor output increases rather than decreases. The breeding ratio is thereby also increased. Excess heat in the breeder reactor primary circuit is removed via a separate coolant circuit provided with a heat consumer. (Z.M.)

  8. Movimentação de molares inferiores ancorados em mini-parafusos Mandibular molar uprighting, using mini-screw as anchorage

    Directory of Open Access Journals (Sweden)

    Rosana Canteras Di Matteo

    2005-08-01

    Full Text Available Freqüentemente a movimentação ortodôntica exige recursos adicionais de ancoragem. Os mini-parafusos têm-se apresentado como uma possível solução. O propósito deste trabalho foi estabelecer um método para a verticalização de molares inferiores inclinados para mesial, utilizando ancoragem em mini-parafusos colocados na região de linha oblíqüa externa da mandíbula. Foram selecionados três pacientes entre 40 a 48 anos (dois do gênero feminino, um do gênero masculino, com molares inferiores inclinados para mesial e distalmente posicionados às áreas edêntulas. Os pacientes foram tratados ortodonticamente durante um período de 6 a 12 meses, com técnica ortodôntica MD3. Mini-parafusos de titânio foram colocados bilateralmente com anestesia local. Uma incisão sobre a linha oblíqüa externa da mandíbula, medindo aproximadamente 1 cm foi realizada em cada lado, distalmente aos molares inclinados. Após descolamento muco-periosteal, mini-parafusos foram implantados e foram realizadas suturas deixando suas cabeças exteriorizadas. Uma semana após a remoção das suturas, cargas ortodônticas (entre 150 a 200 gramas/força foram aplicadas através de forças elásticas. Verificamos que alguma inflamação foi observada ao redor dos mini-parafusos, mas foi controlada com procedimentos de higienização. O procedimento cirúrgico é simples, podendo ser realizado pelo ortodontista; as formas dimensionais dos mini-parafusos são adequadas e estes são de fácil remoção após uso. Concluímos que o uso de mini-parafusos representa uma alternativa efetiva de ancoragem ortodôntica na verticalização de molares inferiores.Tooth movement frequently requires additional anchorage resources. Mini-screws have been used as a possible solution to this matter. The purpose of this study was to establish a method of mandibular molar uprighting, using mini-screw as anchorage, positioned on the mandibular external oblique line, behind and

  9. Relationship between mandibular condyle and angle fractures and the presence of mandibular third molars.

    Science.gov (United States)

    Mah, Deuk-Hyun; Kim, Su-Gwan; Moon, Seong-Yong; Oh, Ji-Su; You, Jae-Seek

    2015-02-01

    We retrospectively evaluated the impact of mandibular third molars on the occurrence of angle and condyle fractures. This was a retrospective investigation using patient records and radiographs. The sample set consisted of 440 patients with mandibular fractures. Eruption space, depth and angulation of the third molar were measured. Of the 144 angle fracture patients, 130 patients had third molars and 14 patients did not. The ratio of angle fractures when a third molar was present (1.26 : 1) was greater than when no third molar was present (0.19 : 1; odds ratio, 6.58; Pcondyle fractures patients, the third molar was present in 84 patients and absent in 57 patients. The ratio of condyle fractures when a third molar was present (0.56 : 1) was lower than when no third molar was present (1.90 : 1; odds ratio, 0.30; Pfractures with third molars and the ratio of condyle fractures without a third molar were statistically significant. The occurrence of angle and condyle fractures was more affected by the continuity of the cortical bone at the angle than by the depth of a third molar. These results demonstrate that a third molar can be a determining factor in angle and condyle fractures.

  10. Microstructure of a tribosphenic molar - comparative analysis

    OpenAIRE

    ŠPOUTIL, František

    2010-01-01

    The proposed thesis concerns in the study of tribosphenic molar, the key apomorphy of mammalian clade, mainly in structure and development of its enamel coat. As the main model species served us European vespertilionid bat Myotis myotis. The aims of this thesis are: (1) to describe structure and microstructure of enamel in tribosphenic molars in detail; (2) to compare it with unicuspid teeth of the same dentition; (3) to describe mineralization process and enamel maturation in insectivorous d...

  11. Distribution and characteristics of molar-incisor hypomineralization

    Directory of Open Access Journals (Sweden)

    Janković Svjetlana

    2014-01-01

    Full Text Available Background/Aim. Developmental disorders of teeth are the problems that are becoming more present in pediatric dentistry, especially on first permanent molars and incisors. Molar Incisor Hypomineralization (MIH is proposed term for this phenomenon. The aim of this study was to establish the MIH prevalence in children living in the Foča municipality (Bosnia and Herzegovina as well as to assess characteristics and expression of hypomineralization within the tested population. Methods. A total of 141 children from the Foča municipality, 8 years of age, were included in this study. Criteria according to Weerhejm have been used for diagnosis of hypomineralization: demarcated opacity (DO, post-eruptive breakdown (PEB, atypical restoration (AR, extracted molars due to MIH (E-MIH and unerupted tooth (UT. Level and the prominence of color changes have been determined for patients with DO, PEB and AR. Results. MIH in this area was present in 12.8% of children. The prevalence of MIH changes expressed in percentages was as follows: DO was at 9.2%, PEB in 3.5%, AR in 5.6%, while E-MIH was 5.6%. A total of 9.9% of the examinees had mild, 5.6% moderate, and 7.8% severe form of MIH. White form of MIH defects was found in 9.9% of the examinees, white-yellow one in 5.6% and yellow-brown color in 3.5% of the examined children. These changes were more often present in the lower jaw (60.3%. In total, 6.4% of children had these changes present only on molars, while 6.4% of them both on molars and incisors simultaneously. Conclusion. A total of 12.8% of the examinees with MIH is not to be disregarded. With timely diagnosis, prevention and therapy complications could be avoided or mitigated.

  12. Fatigue resistance of CAD/CAM resin composite molar crowns.

    NARCIS (Netherlands)

    Shembish, F.A.; Tong, H.; Kaizer, M.; Janal, M.N.; Thompson, V.P.; Opdam, N.J.M.; Zhang, Y.

    2016-01-01

    OBJECTIVE: To demonstrate the fatigue behavior of CAD/CAM resin composite molar crowns using a mouth-motion step-stress fatigue test. Monolithic leucite-reinforced glass-ceramic crowns were used as a reference. METHODS: Fully anatomically shaped monolithic resin composite molar crowns (Lava

  13. A Survey of Removable Partial Denture (RPD Retentive Elements in Relation to Type of Edentulism and Abutment Teeth in Commercial Laboratories in Athens

    Directory of Open Access Journals (Sweden)

    Michael Sotiriou

    2014-01-01

    Full Text Available Objective. The aim of this survey was to record removable partial denture (RPD retentive elements and abutment teeth in partially edentulous patients, identified in commercial laboratories in Athens, Greece. Material and Methods. 628 master casts with the corresponding cast metal frameworks used in the construction of RPDs were evaluated. Casts were photographed to identify the number and position of existing teeth, the partial edentulism class and the retentive elements. Prevalence tables and the x2 test were used for the statistical analysis of the collected data (α=.05. Results. There were 276 maxillary (43.9% and 352 (56.1% mandibular casts. Maxillary edentulism entailed almost a total absence of right third molars in 96.7% and left third molars 96.0% of casts, with lower rates for the first and second molars. Edentulism in the posterior mandible presented a similar pattern. The most profound findings concerning retentive elements were: 91.9% of the retainers used were clasps and the remaining 8.1% were attachments. Of the clasps used, 48.9% were of the Roach Τ type, a finding more common in Kennedy Class I as compared to other Kennedy Classes (p<0.01. The circumferential clasps accounted for 19.3% of the total clasps used, and it was less frequently presented (8.8% in Kennedy I Classes (p<0.01. Conclusions. Roach clasps were used in the majority of cases whereas RPI clasps and attachments were rarely used.

  14. Endodontic treatment of an unusual connation of permanent mandibular molars: a case report.

    Science.gov (United States)

    Liu, Shengbo; Fan, Bing; Peng, Bin; Fan, Mingwen; Bian, Zhuan

    2006-10-01

    A 27-year-old patient with an anomalous mandibular molar was referred for endodontic therapy. Clinical and radiographic examination revealed the connation of a second mandibular molar with a third molar. Challenging endodontic therapy was performed in the unusual connated molars. A 2-year recall showed good treatment result.

  15. MicroCT study on the enamel mineral density of primary molars

    NARCIS (Netherlands)

    Elfrink, M.E.C.; Kalin, K.; van Ruijven, L.J.; ten Cate, J.M.; Veerkamp, J.S.J.

    2016-01-01

    Aim The aim of this study is to report on the mineral density of the enamel of primary molars related to the age of the child and to compare the mineral density of sound and carious enamel in those molars. Materials and methods This study included 23 children and 41 extracted primary molars. The

  16. Standard molar enthalpies of formation of monochloroacetophenone isomers

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro da Silva, Manuel A.V., E-mail: risilva@fc.up.p [Centro de Investigacao em Quimica, Department of Chemistry and Biochemistry, Faculty of Science, University of Porto, Rua do Campo Alegre, 687, P-4169-007 Porto (Portugal); Amaral, Luisa M.P.F. [Centro de Investigacao em Quimica, Department of Chemistry and Biochemistry, Faculty of Science, University of Porto, Rua do Campo Alegre, 687, P-4169-007 Porto (Portugal)

    2010-12-15

    The standard (p{sup 0}=0.1MPa) molar enthalpies of formation of the liquids 2'-, 3'-, and 4'-chloroacetophenones were derived from the standard molar energies of combustion, in oxygen, to yield CO{sub 2}(g) and HCl . 600H{sub 2}O(l), at T = 298.15 K, measured by rotating-bomb combustion calorimetry. The Calvet microcalorimetry was used to measure the enthalpies of vaporization of the three compounds. These two thermodynamic parameters yielded the standard molar enthalpies of formation of the chloroacetophenone isomers, in the gaseous phase, at T = 298.15 K. (table) An empirical scheme, developed by Cox, was used to estimate the gas-phase enthalpies of formation and the obtained values were compared with the experimental ones.

  17. Three-dimensional analysis of third molar development to estimate age of majority.

    Science.gov (United States)

    Márquez-Ruiz, Ana Belén; Treviño-Tijerina, María Concepción; González-Herrera, Lucas; Sánchez, Belén; González-Ramírez, Amanda Rocío; Valenzuela, Aurora

    2017-09-01

    Third molars are one of the few biological markers available for age estimation in undocumented juveniles close the legal age of majority, assuming an age of 18years as the most frequent legal demarcation between child and adult status. To obtain more accurate visualization and evaluation of third molar mineralization patterns from computed tomography images, a new software application, DentaVol©, was developed. Third molar mineralization according to qualitative (Demirjian's maturational stage) and quantitative parameters (third molar volume) of dental development was assessed in multi-slice helical computed tomography images of both maxillary arches displayed by DentaVol© from 135 individuals (62 females and 73 males) aged between 14 and 23years. Intra- and inter-observer agreement values were remarkably high for both evaluation procedures and for all third molars. A linear correlation between third molar mineralization and chronological age was found, with third molar maturity occurring earlier in males than in females. Assessment of dental development with both procedures, by using DentaVol© software, can be considered a good indicator of age of majority (18years or older) in all third molars. Our results indicated that virtual computed tomography imaging can be considered a valid alternative to orthopantomography for evaluations of third molar mineralization, and therefore a complementary tool for determining the age of majority. Copyright © 2017 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.

  18. Size of the lower third molar space in relation to age in Serbian population.

    Science.gov (United States)

    Zelić, Ksenija; Nedeljković, Nenad

    2013-10-01

    It is considered that the shortage of space is the major cause of the third molar impaction. The aim of this study was to establish the frequency of insufficient lower third molar eruption space in Serbian population, to question the differences in this frequency in the subjects of different age, to determine the influence of the lower third molar space (retromolar space) size on third molar eruption, and to investigate a possible correlation between the size of gonial angle and the space/third molar width ratio. Digital orthopantomograms were taken from 93 patients divided into two groups: early adult (16-18 years of age) and adult (18-26) patients. Retromolar space, mesiodistal third molar crown width, gonial angle and eruption levels were measured. The space/third molar width in early adult subjects was smaller (p third molars erupted in case of enough space in both age groups (p third molar width ratio is more favorable in adult subjects. Gonial angle is not in correlation with the retromolar space/third molar width ratio.

  19. Thermophysical Properties of Cold and Vacuum Plasma Sprayed Cu-Cr-X Alloys, NiAl and NiCrAlY Coatings. Part 2; Specific Heat Capacity

    Science.gov (United States)

    Raj, S. V.

    2017-01-01

    Part I of the paper discussed the temperature dependencies of the electrical resistivities, thermal conductivities, thermal diffusivities and total hemispherical emissivities of several vacuum plasma sprayed (VPS) and cold sprayed copper alloy monolithic coatings, VPS NiAl, VPS NiCrAlY, extruded GRCop-84 and as-cast Cu-17(wt.%)Cr-5%Al. Part II discusses the temperature dependencies of the constant pressure specific heat capacities, CP, of these coatings. The data were empirically were regression-fitted with the equation: CP = AT4 + BT3 + CT2 + DT +E where T is the absolute temperature and A, B, C, D and E are regression constants. The temperature dependencies of the molar enthalpy, molar entropy and Gibbs molar free energy determined from experimental values of molar specific heat capacity are reported. Calculated values of CP using the Neumann-Kopp (NK) rule were in poor agreement with experimental data. Instead, a modification of the Neumann-Kopp rule was found to predict values closer to the experimental data with an absolute deviation less than 6.5%. The specific molar heat capacities for all the alloys did not agree with the Dulong-Petit law, and CP is greater than 3R, where R is the universal gas constant, were measured for all the alloys except NiAl for which CP is less than 3R at all temperatures.

  20. Management of large losses of substances molars

    OpenAIRE

    Reynal, Florence

    2016-01-01

    This work aims to compare the different coronary restorative materials used for large tooth losses in primary molars. The first part of this thesis is dedicated to a description of the four main materials used in coronary restorations of molars : amalgam, glass-ionomer cements, resin-based composite and pedodontic crown. The second part is a systematic review of the literature. The aim is to compare the long-term survival rates of different restoration techniques, in order to help the practit...

  1. The temporal behaviour of MHD waves in a partially ionized prominence-like plasma: Effect of heating and cooling

    Science.gov (United States)

    Ballester, J. L.; Carbonell, M.; Soler, R.; Terradas, J.

    2018-01-01

    Context. During heating or cooling processes in prominences, the plasma microscopic parameters are modified due to the change of temperature and ionization degree. Furthermore, if waves are excited on this non-stationary plasma, the changing physical conditions of the plasma also affect wave dynamics. Aims: Our aim is to study how temporal variation of temperature and microscopic plasma parameters modify the behaviour of magnetohydrodynamic (MHD) waves excited in a prominence-like hydrogen plasma. Methods: Assuming optically thin radiation, a constant external heating, the full expression of specific internal energy, and a suitable energy equation, we have derived the profiles for the temporal variation of the background temperature. We have computed the variation of the ionization degree using a Saha equation, and have linearized the single-fluid MHD equations to study the temporal behaviour of MHD waves. Results: For all the MHD waves considered, the period and damping time become time dependent. In the case of Alfvén waves, the cut-off wavenumbers also become time dependent and the attenuation rate is completely different in a cooling or heating process. In the case of slow waves, while it is difficult to distinguish the slow wave properties in a cooling partially ionized plasma from those in an almost fully ionized plasma, the period and damping time of these waves in both plasmas are completely different when the plasma is heated. The temporal behaviour of the Alfvén and fast wave is very similar in the cooling case, but in the heating case, an important difference appears that is related with the time damping. Conclusions: Our results point out important differences in the behaviour of MHD waves when the plasma is heated or cooled, and show that a correct interpretation of the observed prominence oscillations is very important in order to put accurate constraints on the physical situation of the prominence plasma under study, that is, to perform prominence

  2. Molaren Inzisiven Hypomineralisation und Milchmolaren Hypomineralisation - klinisches Erscheinungsbild, Prävalenz und deren Ursachen - Molar Incisor Hypomineralisation and Deciduous Molar Hypomineralisation - clinical appearance, prevalence and determinants for its occurrence

    NARCIS (Netherlands)

    Elfrink, M.E.C.; Weerheijm, K.L.

    2012-01-01

    Background: Molar Incisor Hypomineralisation (MIH) and Deciduous Molar Hypomineralisation (DMH) are frequently occurring dental problems in children. Children with MIH have demarcated opacities in their erupting first permanent molars often in combination with demarcated opacities in their permanent

  3. Heat-transfer in a partially-blocked sodium-cooled rod bundle

    International Nuclear Information System (INIS)

    Han, J.T.

    1979-01-01

    Heat transfer coefficients were experimentally determined for 31-rod sodium-cooled bundle with a 6-subchannel central blockage. The Nusselt number is presented as a function of the Peclet number for both the free flow region undisturbed by the blockage and the wake region immediately downstream of the blockage. Results are compared with the existing correlations for liquid metals. The heat transfer coefficient was generally higher in the unblocked free flow region than in the wake region. A leak at the blockage improved the heat transfer coefficient in the wake region

  4. Management of inflammatory complications in third molar surgery: A ...

    African Journals Online (AJOL)

    Background: Pain, swelling and trismus are common complications associated with third molar surgery. These complications have been reported to have an adverse effect on the quality of life of patients undergoing third molar surgery. Objective: To review the different modalities of minimizing inflammatory complications in ...

  5. Heat capacity and thermodynamic properties of N-(2-cyanoethyl) aniline (C9H10N2)

    International Nuclear Information System (INIS)

    Tian Qifeng; Tan Zhicheng; Shi Quan; Xu Fen; Sun Lixian; Zhang Tao

    2005-01-01

    The low temperature heat capacities of N-(2-cyanoethyl)aniline were measured with an automated adiabatic calorimeter over the temperature range from 83 to 353 K. The temperature corresponding to the maximum value of the apparent heat capacity in the fusion interval, molar enthalpy and entropy of fusion of this compound were determined to be 323.33 ± 0.13 K, 19.4 ± 0.1 kJ mol -1 and 60.1 ± 0.1 J K -1 mol -1 , respectively. Using the fractional melting technique, the purity of the sample was determined to be 99.0 mol% and the melting temperature for the tested sample and the absolutely pure compound were determined to be 323.50 and 323.99 K, respectively. A solid-to-solid phase transition occurred at 310.63 ± 0.15 K. The molar enthalpy and molar entropy of the transition were determined to be 980 ± 5 J mol -1 and 3.16 ± 0.02 J K -1 mol -1 , respectively. The thermodynamic functions of the compound [H T - H 298.15 ] and [S T - S 298.15 ] were calculated based on the heat capacity measurements in the temperature range of 83-353 K with an interval of 5 K

  6. Pressure distribution of implant-supported removable partial dentures with stress-breaking attachments.

    Science.gov (United States)

    Kono, Kentaro; Kurihara, Daisuke; Suzuki, Yasunori; Ohkubo, Chikahiro

    2014-04-01

    This in vitro study investigated the pressure distribution of the implant-supported removable partial dentures (RPDs) with the stress-breaking attachments under the occlusal force. The experimental model of bilateral missing premolars and molars was modified from a commercial simulation model. Five pressure sensors were embedded near the bilateral first molars, first premolars, and medio-lingual alveolar crest. Two implants were placed near the second molars, and they were connected to the denture base using the following conditions: complete separation between the denture base and implant with cover screws (CRPD), flexible connection with a stress-breaking ball (SBB) attachment, and rigid connection without stress breaking with healing caps (HC). The pressure at five different areas of the soft tissue and the displacement of the RPDs were simultaneously measured, loading up to 50 N. The coefficient of variation (CV) for each connection was calculated from all data of the pressure at five areas to evaluate the pressure distribution. The pressure on medio-lingual alveolar crest and molars of the HC was less than SBB and CRPD. In contrast, the pressure on premolars of SBB was greater than for the HC and CRPD. The CV of SBB was less than that of HC and CRPD. Denture displacement of HC and SBB was less than for CRPD. Within the in vitro limitations, precise denture settlements and pressure distribution under the denture base could be controlled using an SBB attachment. An SBB attachment might be able to protect the implant from harmful force. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  7. Radiographic correlation of dental and skeletal age: Third molar, an age indicator.

    Science.gov (United States)

    Suma, Gn; Rao, Balaji B; Annigeri, Rajeshwari G; Rao, Dayashankara Jk; Goel, Sumit

    2011-01-01

    Age estimation plays a great role in forensic investigations, orthodontic and surgical treatment planning, and tooth transplantation. Teeth offer an excellent material for age determination by stages of development below the age of 25 years and by secondary changes after the age of 25 years. Third molar is often not included for this purpose due to its notorious developmental patterns. The aim of this study was to evaluate the development of third molar anlage in relation to skeletal maturities and the chronological age. One hundred and fifty-six young individuals, 78 males and 78 females, were selected. The stages of development of all the third molars in every individual were determined from panoramic radiographs. The skeletal development was assessed using hand wrist radiographs. Data were analyzed statistically for mean value, standard deviation and the relationship between the recorded characteristics. A STRONG CORRELATION WAS FOUND BETWEEN THIRD MOLAR DEVELOPMENT AND SKELETAL MATURITY (IN MALES: r=0.88, Pthird molar and 0.89 for mandibular third molar, Page, developmental stages of third molars and maturation of epiphyses of hand. Any of the three parameters could be used for the assessment of other maturities.

  8. Autotransplantation of a mandibular third molar: A case report

    Directory of Open Access Journals (Sweden)

    Elham Najafi

    2017-09-01

    Full Text Available Tooth autotransplantation defines as transition of one tooth from one position to another, in same individual. It is a biological procedure in which teeth have the potential to induce alveolar bone growth. It can be applied in patients before adolescence growth is finished. It significantly reduces time and cost compared to implants. Healing rapidly occurs and function is regained almost immediately. Our case was a 15-year-old male that his left mandibular third molar transplanted to the second molar sight after extraction of second molar because of unrestorable crown. During 9 month follow up transplanted tooth was asymptomatic, functional and responsive to sensibility tests. (Cold test, EPT.

  9. Variant Root Morphology of Third Mandibular Molar in Normal and ...

    African Journals Online (AJOL)

    isaac kipyator

    2017-11-12

    Nov 12, 2017 ... ABSTRACT. The mandibular third molar poses a challenge to dental surgeons due to it's unpredictable morphology ... treatment in the School of Dental Sciences since 2010. ... mandibular third molar include presence of three.

  10. Prevalência de perda precoce de molares decíduos: estudo retrospectivo = Prevalence of early loss of deciduous molars: a retrospective study

    Directory of Open Access Journals (Sweden)

    Alessandro Leite Cavalcanti

    2008-07-01

    Full Text Available Este estudo retrospectivo determinou a prevalência da perda precoce demolares decíduos em pacientes atendidos na clínica de Odontopediatria da Universidade Estadual da Paraíba. Foram examinados 515 prontuários, sendo os dados registrados em um formulário. Foram analisadas as variáveis: gênero, idade, tipo de molar decíduo perdido,arcada dentária (maxilar ou mandibular e lado (direito e esquerdo. Observou-se que a prevalência de perda precoce foi de 15,1%, existindo uma distribuição similar entre os gêneros. Em relação à idade da criança, a maior freqüência de perda acometeu pacientescom sete anos (32,1%. Houve distribuição equitativa da perda dentária entre as arcadas superior e inferior, com 43,6% cada uma, sendo o lado esquerdo o mais acometido (41%. O segundo molar superior esquerdo foi o mais acometido (17,9%, seguido do primeiromolar decíduo superior direito (16,1%. Pode-se concluir que a prevalência de perda precoce foi baixa e que os molares decíduos superiores foram os dentes mais comumente perdidos.This retrospective study determined the prevalence of early loss of deciduous molars in patients enrolled at the Pediatric Dentistry clinic at the State University of Paraíba. A review of 515 patient records were analyzed, registered in a form. The following variables were analyzed: gender, age, type of deciduous molar loss, region (maxilla or mandible and side (right and left. It was observed that the prevalence of early tooth loss was 15.1% and there was a similar distribution between the genders. In regard to age, the greatest frequency of tooth loss involved patients at 7 years old (32.1%. There was a similar distribution of tooth loss between the maxilla and mandible regions, at 43.6% each, with the left side being themost involved (41%. The second upper left deciduous molar was the most commonly missing tooth (17.9%, followed by the first upper right deciduous molar (16.1%. It can be concluded that the

  11. Western Saudi adolescent age estimation utilising third molar development.

    Science.gov (United States)

    Alshihri, Amin M; Kruger, Estie; Tennant, Marc

    2014-07-01

    The aim of this study was to establish reference data on third molar morphology/development for age estimation in Western Saudi adolescents, between ages 14 and 23 years of old. The orthopantomograms of 130 individuals (males and females), were examined, and the stage of third molar development were evaluated. Mean ages, standard deviations, and percentile distributions are presented for each stage of development. The mean estimated age for all participants (n = 130) was 219.7 months, and this differed significantly (P age (226.5 months). Deviations of predicted age from real age showed 28.5% of all participants had their age estimated within 1 year (±12 months) of their chronological age. Most (43%) had their age underestimated by more than 12 months and the remaining 28.5% had their age overestimated by more than 12 months of their chronological age. Differences in left-right symmetry information of third molars were detected and were higher in the maxilla (92%) than in the mandible (82%). For all molars reaching stage "H" most individuals (males and females) were over the age 18 years of old. Males reach the developmental stages earlier than females. Third molar tooth development can be reliably used to generate mean age and the estimated age range for an individual of unknown chronological age. Further studies with large populations are needed for better statistical results.

  12. Variabilidad de las proporciones molares en poblaciones humanas: un abordaje empleando modelos del desarrollo y experimentales / Variability of molar proportions in human populations: insights from developmental models and experiments in mice

    Directory of Open Access Journals (Sweden)

    Lucas A. D´Addona

    2016-03-01

    Full Text Available Los datos sobre la variación dental interpoblacional y sobre los mecanismos que regulan el desarrollo dental aportados por estudios experimentales aún no han sido integrados en el contexto de investigaciones antropobiológicas. En este sentido, el presente trabajo se propone: a evaluar la consistencia entre la variación de las proporciones molares en poblaciones humanas que exhiben gran variación en el tamaño dental con las predicciones derivadas de un modelo de desarrollo dental de cascada inhibitoria, y b analizar el efecto de los factores sistémicos que controlan el crecimiento del organismo sobre las proporciones de los molares inferiores empleando cepas de Mus musculus. Se calcularon las áreas de los molares inferiores mediante los diámetros bucolingual y mesiodistal. La variación interpoblacional en las proporciones M2/M1 y M3/M1 fue concordante con las expectativas derivadas del modelo y la mayoría de los grupos exhibieron una tendencia a la reducción del tamaño en sentido antero-posterior. Asimismo, se observó una asociación significativa y positiva entre el área molar total y las proporciones molares. En los modelos experimentales la alteración del crecimiento por factores sistémicos (subnutrición proteica y reducción de la hormona de crecimiento resultó en la disminución del área molar total y cambios en las proporciones molares. Estos últimos, consistentes con el incremento del efecto inhibitorio en sentido antero-posterior. En conjunto, los resultados sugieren que la modificación de los factores sistémicos que regulan el área molar total podría conducir a cambios en la proporción de activadores-inhibidores y contribuir a la diferenciación interpoblacional en las proporciones molares. Palabras clave: Modelo de cascada inhibitoria; tamaño dental; aproximación experimental y comparativa Data on dental variation among human populations and the mechanisms regulating tooth development elucidated by

  13. Age of patient at the extraction of the third molar.

    Science.gov (United States)

    Kautto, A; Vehkalahti, M M; Ventä, I

    2018-04-13

    The purpose of this study was to assess the age of patients at the time of extraction of third molars. Our data included all routine and surgical extractions of third molars (n=8199 teeth) performed by general and specialist dentists of the public oral health services of the city of Helsinki over the period 2013-2014. Measurements included patient's age, gender, the identified third molar, the type of anaesthesia, the method of extraction, and the diagnosis at extraction. Patients' ages ranged from 10 to 99years. We found significant differences between younger and older age groups: third molar extractions occurred more often for women than for men below the age of 30years (Page of 40years, but the corresponding prevalences reversed after the age of 40years. Diagnoses at extraction differed between younger and older patients. We conclude that the treatment pattern of third molars at public health services varies greatly over a lifetime, and that a greater variety exists than had been reported previously from oral and maxillofacial units. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. A Survey of Removable Partial Denture (RPD) Retentive Elements in Relation to the Type of Edentulism and Abutment Teeth Found in Commercial Laboratories, Athens, Greece

    Science.gov (United States)

    Sotiriou, Michael; Zissis, Alcibiades

    2014-01-01

    Objective The aim of this survey was to record removable partial denture (RPD) retentive elements and abutment teeth in partially edentulous patients, identified in commercial laboratories in Athens, Greece. Material and Methods 628 master casts with the corresponding cast metal frameworks used in the construction of RPDs were evaluated. Casts were photographed to identify the number and position of existing teeth, the partial edentulism class and the retentive elements. Prevalence tables and the x2 test were used for the statistical analysis of the collected data (α=.05). Results There were 276 maxillary (43.9%) and 352 (56.1%) mandibular casts. Maxillary edentulism entailed almost a total absence of right third molars in 96.7% and left third molars 96.0% of casts, with lower rates for the first and second molars. Edentulism in the posterior mandible presented a similar pattern. The most profound findings concerning retentive elements were: 91.9% of the retainers used were clasps and the remaining 8.1% were attachments. Of the clasps used, 48.9% were of the Roach Τ type, a finding more common in Kennedy Class I as compared to other Kennedy Classes (p<0.01). The circumferential clasps accounted for 19.3% of the total clasps used, and it was less frequently presented (8.8%) in Kennedy I Classes (p<0.01). Conclusions Roach clasps were used in the majority of cases whereas RPI clasps and attachments were rarely used. PMID:27688367

  15. The third molar as an age marker in adolescents: new approach to age evaluation.

    Science.gov (United States)

    Rozkovcova, Eva; Dostalova, Tatjana; Markova, Marie; Broukal, Zdenek

    2012-09-01

    Adolescence is a relatively short period between childhood and adulthood. It is very difficult to determine adulthood based on biological indicators. The third molar may be considered a potential age marker for the period between the ages of 16-21. Our study evaluated a set of 1700 panoramic radiographs of individuals aged between 5 and 21 years. Results confirmed the statistically significant difference in the course of third molars development. The mean deviation for individuals with one third molar agenesis is -0.98 years, for individuals with two third molars agenesis -1.89 years, and with three molars agenesis -3.28 years. Thus, the extent of the deviation is directly proportional to the number of unformed third molars. The calculation of age according to the mean of stages of all third molars could lead to the underestimation of age. No intergender differences were found. Age determination using third molars could be used for forensic purposes. © 2012 American Academy of Forensic Sciences.

  16. [Application of hand-use ProTaper instruments in endodontic treatment of molar canals].

    Science.gov (United States)

    Ma, Sui-qi; Xie, Qian; Zhou, Yin-feng

    2010-07-01

    To evaluate the application of hand-use ProTaper instruments in endodontic treatment of molar canals. A total of 203 permanent molars were randomly divided into the experimental group (99 molars) and control group (104 molars) prepared by hand-use ProTaper instruments and standard stainless steel K-file, respectively. The molars in the two groups were obturated by cold lateral condensation technique. The root canal preparation and obturation were evaluated by radiograph, and the working time of preparation and post-operative emergencies were analyzed. The preparation time in the experimental group was obviously shorter than that in the control group (Phand-use ProTaper instruments may improve the effect of root canal treatment of the molars and shorten the working time and reduce the post-operative emergencies.

  17. Fibrous epulis associated with impacted lower right third molar

    Directory of Open Access Journals (Sweden)

    Ni Putu Mira Sumarta

    2009-12-01

    Full Text Available Background: Epulis or epulides are lesions associated with gingival tissues. Fibrous epulis is a type of hyperplastic fibrous tissue mass located at the gingival which is slow growing, painless, having same color as the oral mucosa and firm on palpation. Anterior regions of the oral cavity are the frequently affected sites as these areas are more prone to be affected by calculus deposition and poor plaque control due to frequent teeth malposition. Removal of any irritating factors and excision of the lesion are the usual treatments. Purpose: This case report presents a rare case of fibrous epulis which occurred in the posterior region of the oral cavity and associated with impacted lower third molar. Case: A case of fibrous epulis at the lower right third molar area of three months duration is presented. The mass was slow growing, painless and on examination it was a pedunculated mass overlying the unerupted lower right third molar, having same color with the oral mucosa and firm on palpation. Clinically, the lesion was diagnosed as fibrous epulis associated with impacted lower right third molar. Case management: The treatment were surgical excision of the epulis and removal of the lower right third molar. The histopathology result showed tissue with squamous epithelial lining, achanthotic fibrous connective tissue, mononuclear inflammatory cells and few capillaries without signs of malignancy. This is consistent with the diagnosis of fibrous epulis. Conclusion: Fibrous epulis, although frequently occurred at the anterior region of the oral cavity, may rarely grow at the area of lower third molar. This phenomenon supports the theory that epulis can grow on any surface of oral mucous membrane as long as local irritants are present.

  18. Pendulum Therapy of Molar Distalization in Mixed Dentition.

    Science.gov (United States)

    Patil, Raju Umaji; Prakash, Amit; Agarwal, Anshu

    2016-01-01

    Early and timely pedo-orthodontic treatment is aimed at eliminating the disturbances of skeletal or dentoalveolar development, to harmonize the stomatognathic system before the full eruption of all permanent teeth. The advantages of pendulum appliance are its minimal dependence on patient's compliance (child cooperation), ease of fabrication, onetime activation and adjustment of the springs if necessary to correct minor transverse and vertical molar positions. This article reports a successful treatment method of class II malocclusion with pendulum appliance in mixed dentition phase. Distalization of maxillary molar was done, followed by guidance of canine impaction orthodontically and other dental correction using 0.022 MBT appliances. Posttreatment results were stable and remarkable. How to cite this article: Patil RU, Prakash A, Agarwal A. Pendulum Therapy of Molar Distalization in Mixed Dentition. Int J Clin Pediatr Dent 2016;9(1):67-73.

  19. Heat transfer properties and thermal cure of glass-ionomer dental cements.

    Science.gov (United States)

    Gavic, Lidia; Gorseta, Kristina; Glavina, Domagoj; Czarnecka, Beata; Nicholson, John W

    2015-10-01

    Under clinical conditions, conventional glass-ionomer dental cements can be cured by application of heat from dental cure lamps, which causes acceleration in the setting. In order for this to be successful, such heat must be able to spread sufficiently through the cement to enhance cure, but not transmit heat so effectively that the underlying dental pulp of the tooth is damaged. The current study was aimed at measuring heat transfer properties of modern restorative glass-ionomers to determine the extent to which they meet these twin requirements. Three commercial glass ionomer cements (Ionofil Molar, Ketac Molar and Equia™ Fill) were used in association with three different light emitting diode cure lamps designed for clinical use. In addition, for each cement, one set of specimens was allowed to cure without application of a lamp. Temperature changes were measured at three different depths (2, 3 and 4 mm) after cure times of 20, 40 and 60 s. The difference among the tested groups was evaluated by ANOVA (P heat irradiation, but much greater temperature increases when exposed to the cure lamp. However, temperature rises did not exceed 12.9 °C. Application of the cure lamp led to the establishment of a temperature gradient throughout each specimen. Differences were typically significant (P heating effect. Because the thermal conductivity of glass-ionomers is low, temperature rises at 4 mm depths were much lower than at 2 mm. At no time did the temperature rise sufficiently to cause concern about potential damage to the pulp.

  20. Partial radiogenic heat model for Earth revealed by geoneutrino measurements

    NARCIS (Netherlands)

    Abe, S.; et al., [Unknown; Decowski, M.P.

    2011-01-01

    The Earth has cooled since its formation, yet the decay of radiogenic isotopes, and in particular uranium, thorium and potassium, in the planet’s interior provides a continuing heat source. The current total heat flux from the Earth to space is 44.2±1.0 TW, but the relative contributions from

  1. Cul3-mediated Nrf2 ubiquitination and antioxidant response element (ARE) activation are dependent on the partial molar volume at position 151 of Keap1.

    Science.gov (United States)

    Eggler, Aimee L; Small, Evan; Hannink, Mark; Mesecar, Andrew D

    2009-07-29

    Nrf2 (nuclear factor erythroid 2-related factor 2) is a transcription factor that activates transcription of a battery of cytoprotective genes by binding to the ARE (antioxidant response element). Nrf2 is repressed by the cysteine-rich Keap1 (kelch-like ECH-associated protein 1) protein, which targets Nrf2 for ubiquitination and subsequent degradation by a Cul3 (cullin 3)-mediated ubiquitination complex. We find that modification of Cys(151) of human Keap1, by mutation to a tryptophan, relieves the repression by Keap1 and allows activation of the ARE by Nrf2. The Keap1 C151W substitution has a decreased affinity for Cul3, and can no longer serve to target Nrf2 for ubiquitination, though it retains its affinity for Nrf2. A series of 12 mutant Keap1 proteins, each containing a different residue at position 151, was constructed to explore the chemistry required for this effect. The series reveals that the extent to which Keap1 loses the ability to target Nrf2 for degradation, and hence the ability to repress ARE activation, correlates well with the partial molar volume of the residue. Other physico-chemical properties do not appear to contribute significantly to the effect. Based on this finding, a structural model is proposed whereby large residues at position 151 cause steric clashes that lead to alteration of the Keap1-Cul3 interaction. This model has significant implications for how electrophiles which modify Cys(151), disrupt the repressive function of Keap1.

  2. Age estimation using development of third molars in South Indian population: A radiological study.

    Science.gov (United States)

    Priyadharshini, K Indra; Idiculla, Jose Joy; Sivapathasundaram, B; Mohanbabu, V; Augustine, Dominic; Patil, Shankargouda

    2015-05-01

    To assess the estimation of chronological age based on the stages of third molar development following the eight stages (A-H) method of Demirjian et al. in Chennai population of South India. A sample consisting of 848 individuals (471 males and 377 females) aged between 14 and 30 years was randomly selected for the clinical evaluation and 323 orthopantomograms with clinically missing third molars were taken for radiological evaluation using Demirjian's method from a Chennai population of known chronological age and sex. Statistical analysis was performed using Pearson's Chi-square test and mean values were compared between the study groups using t-test or analysis of variance (ANOVA) followed by Tukey's highly significant difference (HSD). In the present study, P age of having clinically completely erupted maxillary third molars was 22.41 years in male subjects and 23.81 years in female subjects and that of mandibular third molars was 21.49 years in male subjects and 23.34 years in female subjects. Mandibular third molars were clinically missing more often in females than in males. Eruption of mandibular third molars was generally ahead of the emergence of maxillary third molars into the oral cavity. Third molar development between male and female subjects showed statistically significant differences at calcification stage F and stage G in maxillary third molars and stage F in mandibular third molars (P third molar eruption reached Demirjian's formation stages earlier in males than in females. It is suggested that in future studies, to increase the accuracy of age determination, indications of sexual maturity and ossification should also be evaluated in addition to third molar mineralization.

  3. Estudio de volumen molar y refracción molar de miscelas de triglicéridos (triacetina, tributirina o tricaprilina) y alcoholes (etanol, 1-butanol o 1-hexanol)

    OpenAIRE

    Rodríguez Rodríguez, M.; Galán Vallejo, M.; Muñoz Cueto, María J.

    1992-01-01

    Values of molar refraction for every studied mixtures show linear plots versus molar fractions of triglyceride. Values of molar volume show this behaviour, but only for tributyrin-butanol or tricaprylin-butanol miscellas. However, in tributyrin-ethanol mixtures, volume contractions have been found, whereas triacetin-butanol and tributyrin-hexanol show volume expansions. These facts are related to the mode of being structured of the alcohol and triglyceride molecules in mixtures. A linea...

  4. The prevalence and pattern of deciduous molar hypomineralization and molar-incisor hypomineralization in children from a suburban population in Nigeria

    OpenAIRE

    Temilola, Oluwaseyi Dada; Folayan, Morenike Oluwatoyin; Oyedele, Titus

    2015-01-01

    Background Molar Incisor Hypoplasia (MIH) and Deciduous Molar Hypoplasia (DMH) have significant impact on the quality of life of affected individuals. The objective of the study was to determine the prevalence, pattern and clinical presentation of MIH and DMH in children resident in Ile-Ife, Nigeria, and their association with sex and socioeconomic status of the children. Methods Information on age, sex and socioeconomic status was collected from 563 children aged 3 to 5?years and 8 to 10?yea...

  5. Comparison Of Bond Strength Of Orthodontic Molar Tubes Using Different Enamel Etching Techniques And Their Effect On Enamel

    International Nuclear Information System (INIS)

    Abd el Rahman, H.Y.

    2013-01-01

    In fixed orthodontic treatment, brackets and tubes are used for transferring orthodontic forces to the teeth. Those attachments were welded to cemented bands. Fifty years ago, direct bonding of brackets and other attachments has become a common technique in fixed orthodontic treatment. Orthodontists used to band teeth, especially molars and second premolars, to avoid the need for re bonding accessories in these regions of heavy masticatory forces. However, it is a known fact that direct bonding saves chair time as it does not require prior band selection and fitting, has the ability to maintain good oral hygiene, improve esthetics and make easier attachment to crowded and partially erupted teeth. Moreover, when the banding procedure is not performed with utmost care it can damage periodontal and/or dental tissues. Molar tubes bonding decreases the chance of decalcification caused by leakage beneath the bands. Since molar teeth are subjected to higher masticatory impact, especially lower molars, it would be convenient to devise methods capable of increasing the efficiency of their traditional bonding. These methods may include variation in bond able molar tube material, design, bonding materials and etching techniques. For achieving successful bonding, the bonding agent must penetrate the enamel surface; have easy clinical use, dimensional stability and enough bond strength. Different etching techniques were introduced in literature to increase the bond strength which includes: conventional acid etching, sandblasting and laser etching techniques. The process of conventional acid etching technique was invented In (1955) as the surface of enamel has great potential for bonding by micromechanical retention, to form ‘the mechanical lock‘. The primary effect of enamel etching is to increase the surface area. However, this roughens the enamel microscopically and results in a greater surface area on which to bond. By dissolving minerals in enamel, etchants remove the

  6. Adiabatic Fixed-Bed Gasification of Colombian Coffee Husk Using Air-Steam Blends for Partial Oxidation

    Directory of Open Access Journals (Sweden)

    Javier Bonilla

    2017-01-01

    Full Text Available The increasing energy consumption, mostly supplied by fossil fuels, has motivated the research and development of alternative fuel technologies to decrease the humanity’s dependence on fossil fuels, which leads to pollution of natural sources. Small-scale biomass gasification, using air-steam blends for partial oxidation, is a good alternative since biomass is a neutral carbon feedstock for sustainable energy generation. This research presents results obtained from an experimental study on coffee husk (CH gasification, using air-steam blends for partial oxidation in a 10 kW fixed-bed gasifier. Parametric studies on equivalence ratio (ER (1.53 < ER < 6.11 and steam-fuel (SF ratio (0.23 < SF < 0.89 were carried out. The results show that increasing both SF and ER results in a syngas rich in CH4 and H2 but poor in CO. Also, decreased SF and ER decrease the peak temperature (Tpeak at the gasifier combustion zone. The syngas high heating value (HHV ranged from 3112 kJ/SATPm3 to 5085 kJ/SATPm3 and its maximum value was obtained at SF = 0.87 and ER = 4.09. The dry basis molar concentrations of the species, produced under those operating conditions (1.53 < ER < 6.11 and 0.23 < SF < 0.89, were between 1.12 and 4.1% for CH4, between 7.77 and 13.49% for CO, and between 7.54 and 19.07% for H2. Other species were in trace amount.

  7. Management of Unilaterally Impacted Permanent Mandibular First, Second and Third Molars

    Directory of Open Access Journals (Sweden)

    Rohit Mehrotra

    2014-01-01

    Full Text Available This case report describes the treatment of a teenage patient with simultaneous impaction of all three right mandibular permanent molars. The impacted first and second mandibular molars were surgically exposed and orthodontically erupted into good alignment and occlusion while the impacted third molar in the same quadrant was extracted. The unique clinical presentation, various treatment alternatives, the decision making process in finalizing the treatment plan and its clinical implementation are discussed.

  8. A study on morphology control and optical properties of ZnO nanorods synthesized by microwave heating

    International Nuclear Information System (INIS)

    Tsai, M.K.; Huang, C.C.; Lee, Y.C.; Yang, C.S.; Yu, H.C.; Lee, J.W.; Hu, S.Y.; Chen, C.H.

    2012-01-01

    In this study, we present morphology control investigations on zinc oxide (ZnO) nanorods synthesized by microwave heating of a mixture of zinc nitrate hexahydrate and hexamethylenetetramine (HMTA) precursors in deionized water (DI water). To study the morphology and structural variations of the obtained ZnO nanorods in different molar ratio of zinc nitrate hexahydrate to HMTA, X-ray diffraction (XRD), scanning electron microscopy (SEM) images, Raman scattering, and photoluminescence (PL) spectroscopy were measured. XRD and SEM images are utilized to examine the crystalline quality as well as the morphological properties of the ZnO nanorods. It is found that morphology control can be achieved by simply adjusting the reactant concentrations and the molar ratio of zinc nitrate hexahydrate to HMTA. Raman scattering and PL spectroscopy measurements were demonstrated to study the size- and shape-dependent optical response of the ZnO nanorods. The Raman scattering result shows that the intensity of LO mode at around 576 cm -1 decreases with the increase in the molar ratio of zinc nitrate hexahydrate to HMTA, indicating the reduction of defect concentrations in the synthesized ZnO nanorods. Room temperature PL spectrum of the synthesized ZnO nanorods reveals an ultraviolet (UV) emission peak and a broad visible emission. An enhancement of UV emission appears in the PL spectra as the molar ratio of zinc nitrate hexahydrate to HMTA increases, indicating that the defect concentration of the synthesized ZnO nanorods can be reduced by increasing the molar ratio. - Highlights: → Morphology of ZnO nanorods can be controlled via microwave-heating synthesis. → Molar ratio of Zn(NO 3 ) 2 .6H 2 O to C 6 H 12 N 4 affects the aspect ratio of ZnO nanorod. → ZnO nanorod showing higher aspect ratio can exhibit better optical properties.

  9. The volumetric and thermochemical properties of YCl{sub 3}(aq), YbCl{sub 3}(aq), DyCl{sub 3}(aq), SmCl{sub 3}(aq), and GdCl{sub 3}(aq) at T=(288.15, 298.15, 313.15, and 328.15) K and p=0.1 MPa[Trivalent metal chlorides; Densities; Heat capacities; Single ion properties; Calorimetry; Densimetry

    Energy Technology Data Exchange (ETDEWEB)

    Hakin, Andrew W. E-mail: hakin@uleth.ca; Lukacs, Michael J.; Liu, Jin Lian; Erickson, Kristy

    2003-11-01

    Relative densities and massic heat capacities have been measured for acidified aqueous solutions of YCl{sub 3}(aq), YbCl{sub 3}(aq), DyCl{sub 3}(aq), SmCl{sub 3}(aq), and GdCl{sub 3}(aq) at T=(288.15, 298.15, 313.15, and 328.15) K and p=0.1 MPa. These measurements have been used to calculate experimental apparent molar volumes and heat capacities which, when used in conjunction with Young's rule, were used to calculate the apparent molar properties of the aqueous chloride salt solutions. The latter calculations required the use of volumetric and thermochemical data for aqueous solutions of hydrochloric acid that have been previously reported in the literature. The concentration dependences of the apparent molar properties have been modeled using Pitzer ion interaction equations to yield apparent molar volumes and heat capacities at infinite dilution. The temperature and concentration dependences of the apparent molar volumes and heat capacities of each trivalent salt system were modeled using modified Pitzer ion interaction equations. These equations utilized the revised Helgeson, Kirkham, and Flowers equations of state to model the temperature dependences of apparent molar volumes and heat capacities at infinite dilution. Calculated apparent molar volumes and heat capacities at infinite dilution have been used to calculate single ion properties for the investigated trivalent metal cations. These values have been compared to those previously reported in the literature. The differences between single ion values calculated in this study and those values calculated from thermodynamic data for aqueous perchlorate salts are also discussed.

  10. Probabilidad de retención de segundos molares permanentes mandibulares (Estudio piloto

    Directory of Open Access Journals (Sweden)

    Paulo Sandoval Vidal

    Full Text Available Objetivos: Determinar la frecuencia del segundo molar mandibular permanente (MM2 con probabilidad de impactación, en un grupo de pacientes de Ortodoncia de Temuco, Chile. Método: Estudio de corte transversal, con muestra por conveniencia. Se revisaron 2095 fichas de individuos de ambos sexos, con ausencia de patología sindrómica. Los datos recolectados se obtuvieron de radiografías panorámicas. Se midió el ángulo del segundo molar con respecto al plano oclusal, la invasión distal del primer molar y la distancia entre distal del primer molar y el borde anterior de la rama mandibular. Resultados: El promedio de edad de los pacientes relevados fue de 10 años. Se observó un 1,43% de probabilidad de retención de MM2 (n=30; en promedio y el plano el ángulo MM2 resultó de 27° el izquierdo y 26° el derecho; la invasión de MM2 en distal del primer molar resultó de 1,5 mm; el ángulo entre MM2 y el planos oclusal es de 123°; la distancia entre la cara distal del primer molar y el borde anterior de la rama mandibular fue 13 mm. Conclusiones: Existe una baja prevalencia de segundos molares mandibulares permanentes con probabilidad de impactación. La invasión a la cara distal del primer molar fue mayor en pacientes con riesgo de impactación

  11. Apparent molar volumes and viscosity B-coefficients of caffeine in aqueous thorium nitrate solutions at T = (298.15, 308.15, and 318.15) K

    International Nuclear Information System (INIS)

    Sinha, Biswajit; Roy, Pran Kumar; Sarkar, Bipul Kumar; Brahman, Dhiraj; Roy, Mahendra Nath

    2010-01-01

    Apparent molar volumes φ V and viscosity B-coefficients for caffeine in (0.00, 0.03, 0.05, and 0.07) mol . dm -3 aqueous thorium nitrate, Th(NO 3 ) 4 , solutions were determined from solution density and viscosity measurements over the temperature range (298.15 to 318.15) K as function of concentration of caffeine and the relation: φ V 0 =a 0 +a 1 T+a 2 T 2 , have been used to describe the temperature dependence of the standard partial molar volumes φ V 0 . These results have been used to deduce the standard volumes of transfer Δφ V 0 and viscosity B-coefficients of transfer ΔB for caffeine from water to aqueous Th(NO 3 ) 4 solutions for rationalizing various interactions in the ternary solutions. The structure-making or breaking ability of caffeine has been discussed in terms of the sign of (δ 2 φ V 0 /δT 2 ) P . The Friedman-Krishnan co-sphere model was used to explain the transfer volume of caffeine with increasing Th(NO 3 ) 4 molarity. The activation parameters of viscous flow for the ternary solutions were also discussed in terms of transition state theory.

  12. Middle mesial canals in mandibular molars: incidence and related factors.

    Science.gov (United States)

    Nosrat, Ali; Deschenes, Raney J; Tordik, Patricia A; Hicks, M Lamar; Fouad, Ashraf F

    2015-01-01

    Although the internal anatomy of mandibular molars has been extensively studied, information about middle mesial (MM) canals is limited. The primary aim of this retrospective study was to evaluate the incidence of MM canals in mandibular first and second molars. The secondary aim was to correlate the incidence of MM canals with variables of molar type, sex, age, ethnicity, and presence of a second distal canal. All mature permanent first and second mandibular molars treated from August 2012 to May 2014 were included in the analysis. After completion of root canal instrumentation in all main canals, the clinician inspected the isthmus area of the mesial root using the dental operating microscope. If there was a catch point in this area with a file or explorer, the operator spent more time attempting to negotiate an MM canal. Seventy-five mandibular first and second molars were treated during the specified period. Fifteen (20%) teeth had negotiable MM canals. The incidence of MM canals was 32.1% in patients ≤ 20 years old, 23.8% in patients 21-40 years old, and 3.8% in patients > 40 years. Analysis of data revealed a significant difference in the distribution of MM canals among different age groups (P molar type, and presence of a second distal canal were not significant. The incidence of negotiable MM canals overall and their frequency of identification in younger patients were higher than in previous reports. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  13. Modified distal shoe appliance for premature loss of multiple deciduous molars: a case report.

    Science.gov (United States)

    Bhat, Prasanna Kumar; K, Navin H; Idris, Mohammed; Christopher, Pradeep; Rai, Niharika

    2014-08-01

    Preservation of the primary dentition until the normal time of exfoliation is one of the most important factor involved in preventive and interceptive dentistry. The premature loss of second primary molar before the eruption of permanent first molar can create a significant arch space/tooth size discrepancy. Distal shoe space maintainer is a valuable part of the Paediatric Dentist's armamentarium in those cases where the second primary molar is prematurely lost and it helps to guide the first permanent molar into place. Conventional design poses various limitations in cases of premature loss of multiple deciduous molars. Thus, it is required to modify the conventional designs according to the needs of the patient. This case report describes an innovative modification of distal shoe appliance in cases of premature loss of multiple deciduous molars. In the present case, modification of distal shoe space maintainer was advocated because of inadequate abutments caused due to multiple loss of deciduous molars. Bilateral design of distal shoe was planned for unilateral loss of deciduous molars.

  14. Fusion or gemination? An unusual mandibular second molar

    Directory of Open Access Journals (Sweden)

    Angela Jordão Camargo

    2016-01-01

    Full Text Available Fusion and gemination is not an uncommon finding and affected most primary dentition and the permanent maxillary incisors. These changes can develop a series of complication. A 11-year-old male presented radiography finding: an unusual mandibular second molar. A well-documented case brings a challenge for radiologists classify between fusion and gemination. In conclusion, this alteration although common in other regions, there are no case in the literature involving “second and third” molar.

  15. A rare case of retained fourth molar teeth in maxilla and mandible. Case report

    Directory of Open Access Journals (Sweden)

    Rahnama Mansur

    2014-06-01

    Full Text Available The study presents a case of the rarely occurring totally retained fourth molar teeth simultaneously in maxilla and mandible. The appearance of supernumerary teeth is a relatively uncommon dental anomaly and it is rare for patients to have impacted fourth molars in two quadrant. The aim of this work is to describe the presence of unilateral (right fourth molars in the maxilla and the mandible in a young female patient aged 24 years. Orthopantomogram revealed impacted lower third molars but also unerupted unilateral (right upper and lower fourth molars. Before orthodontic treatment, the patient was subsequently admitted for removal of third and fourth impacted upper and lower molars under local anesthesia.

  16. Mandibular second molar with 3 mesial canals and a radix paramolaris

    Directory of Open Access Journals (Sweden)

    N Ragavendran

    2014-01-01

    Full Text Available Mandibular first molar commonly has two roots, the mesial and the distal root. Surprisingly in some mandibular first molar has an unusual extra third root in between mesial and distal root. This extra root is the most commonly seen in lingual side and is called as radix entomolaris. If this extra root is seen on the buccal side, it is termed as radix paramolaris (RP, which is a very rare phenomenon. Recently, various case report studies has shown the presence of third canal in the mesial and distal roots of mandibular molars. They are named as middle mesial and middle distal canal, respectively. Here, we present a case report of mandibular second molar showing three canals in the mesial root and a RP.

  17. An aegialodontid upper molar and the evolution of mammal dentition.

    Science.gov (United States)

    Lopatin, Alexey V; Averianov, Alexander O

    2006-08-25

    The most obvious key synapomorphy of the therian mammals is the tribosphenic pattern of their molars. Tribosphenic teeth are capable of both shearing and grinding, which substantially increase effectiveness of food processing and, in turn, permit evolution of a wide range of dietary specializations. Functional tribospheny developed repeatedly during mammalian evolution but was successful only in the Boreosphenida. The earliest stage in the development of boreosphenidan tribospheny has remained poorly understood, being documented only by lower molars of aegialodontids. Here, we report a known upper molar of an aegialodontid mammal, Kielantherium, from the Early Cretaceous of Mongolia.

  18. Standard molar enthalpies of formation and of sublimation of the terphenyl isomers

    International Nuclear Information System (INIS)

    Ribeiro da Silva, Manuel A.V.; Santos, Luis M.N.B.F.; Lima, Luis M. Spencer S.

    2008-01-01

    The standard (p 0 = 0.1 MPa) molar enthalpies of formation in the crystalline phases of ortho, meta and para-terphenyl isomers, at T = 298.15 K, were derived from the standard molar energies of combustion, measured by mini-bomb combustion calorimetry. The Knudsen mass-loss effusion technique was used to measure the dependence of the vapour pressure of the crystals with the temperature, thus deriving their standard molar enthalpies of sublimation by means of the Clausius-Clapeyron equation. Combining the standard molar enthalpies of formation and sublimation of the crystalline terphenyls, the standard molar enthalpies of formation in the gaseous state, at T = 298.15 K, were derived for the three isomers. Results are provided in a table. The results show small but detectable isomerization enthalpies between the terphenyls, indicating the following relative enthalpic stabilities: m- > p- ∼ o-terphenyl

  19. Standard molar enthalpies of formation of three N-benzoylthiocarbamic-O-alkylesters

    International Nuclear Information System (INIS)

    Ribeiro da Silva, Manuel A.V.; Santos, Luis M.N.B.F.; Schroeder, Bernd; Dietze, Frank; Beyer, Lothar

    2004-01-01

    The standard (p 0 =0.1 MPa) molar enthalpies of combustion in oxygen of three crystalline N-benzoylthiocarbamic-O-alkylesters, PhCONHCSOR, R=Et (Hbtcee), n-Bu (Hbtcbe), n-Hex (Hbtche), were measured at T=298.15 K by rotating bomb calorimetry. The standard molar enthalpies of sublimation of the three compounds were measured using Calvet microcalorimetry. These values were used to derive the standard molar enthalpies of formation of the compounds in their crystalline and gaseous phases, respectively

  20. Requirement of alveolar bone formation for eruption of rat molars

    Science.gov (United States)

    Wise, Gary E.; He, Hongzhi; Gutierrez, Dina L.; Ring, Sherry; Yao, Shaomian

    2011-01-01

    Tooth eruption is a localized event that requires a dental follicle (DF) to regulate the resorption of alveolar bone to form an eruption pathway. During the intra-osseous phase of eruption, the tooth moves through this pathway. The mechanism or motive force that propels the tooth through this pathway is controversial but many studies have shown that alveolar bone growth at the base of the crypt occurs during eruption. To determine if this bone growth (osteogenesis) was causal, experiments were designed in which the expression of an osteogenic gene in the DF, bone morphogenetic protein-6 (BMP6), was inhibited by injection of the 1st mandibular molar of the rat with an siRNA targeted against BMP6. The injection was followed by electroporation to promote uptake of the siRNA. In 45 first molars injected, eruption either was delayed or completely inhibited (7 molars). In the impacted molars, an eruption pathway formed but bone growth at the base of the crypt was greatly reduced as compared to the erupted first molar controls. These studies show that alveolar bone growth at the base of the crypt is required for tooth eruption and that BMP6 may be an essential gene for promoting this growth. PMID:21896048

  1. Modified distal shoe appliance for the loss of a primary second molar: a case report.

    Science.gov (United States)

    Dhull, Kanika Singh; Bhojraj, Nandlal; Yadav, Shweta; Prabhakaran, Sheeja Devi

    2011-01-01

    Preservation of primary teeth until their normal exfoliation plays a crucial role in preventive and interceptive dentistry. Premature loss of the primary second molar prior to the eruption of the permanent first molar in the absence of the primary second molar can lead to mesial movement and migration of the permanent molar before and during its eruption. In such cases, an intra-alveolar type of space maintainer to guide the eruption of the permanent first molar is indicated. In certain cases, however, the conventional design is not practical. This paper describes a new design for distal shoe appliances in cases of primary second molar loss prior to the eruption of the permanent mandibular first molar.

  2. Load Management in District Heating Operation

    OpenAIRE

    Li, Hongwei; Wang, Stephen Jia

    2015-01-01

    Smooth operation of district heating system will avoid installation of expensive peak heat boilers, improve plant partial load performance, increase the system redundancy for further network expansion and improve its resilience to ensuresecurity of supply during severe heating seasons. The peak heating load can be reduced through building demand side management. The building thermal mass can be used to shift the heating supply under the circumstance withoutjeopardizing the consumer thermal co...

  3. Estudios físico-químicos de miscelas de aceites vegetales XIV. Volumen molar, refracción molar y viscosidad de disoluciones de estearato de metilo en ciciohexano, hexano, tetracloroetileno o tricloroetileno

    Directory of Open Access Journals (Sweden)

    Muñoz Cueto, María J.

    1991-02-01

    Full Text Available In the miscelies studied, molar volume and molar refraction values show linear dependence with the molar fraction of methyl stearate. Viscosity values fit Hildebrand's modified equation, where the "Vo" parameter is a linear function of the molar fraction of methyl stearate. Regarding with this three physico-chemical properties, the mixtures studied behave like ideal mixtures of two organic liquids without ionization.

    En todas las miscelas estudiadas los valores del volumen molar y de la refracción molar presentan variaciones lineales en función de la fracción molar de estearato de metilo. Los valores de viscosidad de las miscelas estudiadas se ajustan a la ecuación de fluidez de Hildebrand modificada, siendo su parámetro "Vo" función lineal de la fracción molar de estearato de metilo. En relación con estas tres características, el comportamiento de las miscelas estudiadas no difiere significativamente del correspondiente a una mezcla "ideal" de dos líquidos orgánicos sin ionizar.

  4. Molar Uprighting: A Considerable and Safe Decision to Avoid Prosthetic Treatment

    Science.gov (United States)

    Raveli, Taísa Boamorte; Raveli, Dirceu Barnabé; de Mathias Almeida, Kelei Cristina; Pinto, Ary dos Santos

    2017-01-01

    Background: Tipped lower molar over edentulous space is very common in orthodontics practice when adults seek treatment. The segmented arch technique features a predictable force system that provides a controlled release of force that can produce light and continuous tooth movement. Case Description: A female adult patient, who lost a permanent lower first molar, needed correction of the position of her permanent first molar place. Instead of making space for rehabilitation, it was closed after second molar uprighting and a balanced interdigitation was created without prosthetics. The patient was successfully treated with segmented arch technique using root correction spring activated with geometry VI to promote uprighting of a tipped molar and Niti spring coil to promote space closure. Practical Implications: Segmented arch technique is known to provide predictable light and continuous forces, which is very much indicated in adult treatment. There are several things to consider when orthodontically treating adult patients. Their periodontal conditions might not be ideal, less bone apposition may occur, and side effects of orthodontic tooth movement are expected. Thus, a predictable and controlled orthodontic treatment is needed. PMID:29114332

  5. A note on the Lie symmetries of complex partial differential

    Indian Academy of Sciences (India)

    Folklore suggests that the split Lie-like operators of a complex partial differential equation are symmetries of the split system of real partial differential equations. However, this is not the case generally. We illustrate this by using the complex heat equation, wave equation with dissipation, the nonlinear Burgers equation and ...

  6. Unilateral maxillary molar distalization with zygoma-gear appliance.

    Science.gov (United States)

    Kilkis, Dogan; Bayram, Mehmet; Celikoglu, Mevlut; Nur, Metin

    2012-08-01

    The aim of this study was to present the orthodontic treatment of a 15-year-old boy with a unilateral maxillary molar distalization system, called the zygoma-gear appliance. It consisted of a zygomatic anchorage miniplate, an inner bow, and a Sentalloy closed coil spring (GAC International, Bohemia, NY). A distalizing force of 350 g was used during the distalization period. The unilateral Class II malocclusion was corrected in 5 months with the zygoma-gear appliance. The maxillary left first molar showed distalization of 4 mm with an inclination of 3°. The maxillary premolars moved distally with the help of the transseptal fibers. In addition, there were slight decreases in overjet (-0.5 mm) and maxillary incisor inclination (-1°), indicating no anchorage loss from the zygoma-gear appliance. Preadjusted fixed appliances (0.022 × 0.028-in, MBT system; 3M Unitek, Monrovia, Calif) were placed in both arches to achieve leveling and alignment. After 14 months of unilateral distalization with the zygoma-gear appliance and fixed appliances, Class I molar and canine relationships were established with satisfactory interdigitation of the posterior teeth. Acceptable overjet and overbite were also achieved. This article shows that this new system, the zygoma-gear appliance, can be used for unilateral maxillary molar distalization without anchorage loss. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  7. A New Thermodynamic Calculation Method for Binary Alloys: Part I: Statistical Calculation of Excess Functions

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The improved form of calculation formula for the activities of the components in binary liquids and solid alloys has been derived based on the free volume theory considering excess entropy and Miedema's model for calculating the formation heat of binary alloys. A calculation method of excess thermodynamic functions for binary alloys, the formulas of integral molar excess properties and partial molar excess properties for solid ordered or disordered binary alloys have been developed. The calculated results are in good agreement with the experimental values.

  8. Estudio de mezclas de disolventes orgánicos y triglicéridos de aceite de linaza o los ácidos grasos libres. I.- Volumen molar, refracción molar y viscosidad dinámica

    Directory of Open Access Journals (Sweden)

    Mantell Serrano, C.

    1995-06-01

    Full Text Available Measurements of molar volume, refraction index and dynamic viscosity in mixtures of fatty acids or triglycerides and trichloroethylene, tetrachloroethylene and hexane were realized. Temperature range studied was 278-313 K each 5 K. The relationship between molar volume and molar fraction show high correlation coefficient In fatty acids with trichloroethylene and tetrachloroethylene mixtures. On the other hand, hexane mixtures show little contractions of molar volume at low molar fractions. Triglyceride mixtures present important deviations with regard to the ideality of the molar volume. The adjusts obtained for the molar volume values versus temperature are acceptable, calculating the coefficients of thermal expansion of the studied mixtures. Equally, the adjust of the experimental results of viscosity for two prediction equations are studied: one of additive type and the other of parabolic type.

    Se han realizado medidas del volumen molar, índice de refracción y viscosidad dinámica en el intervalo de temperatura de 278 K a 313 K cada 5 K, a mezclas de ácidos grasos o triglicéridos con tricloroetileno, tetracloroetileno y hexano. Las mezclas de ácidos grasos con tricloroetileno y tetracloroetileno, presentan unos altos coeficientes de correlación para los valores del volumen molar frente a la fracción molar, mientras que las mezclas con hexano, a fracciones molares bajas, manifiestan una pequeña contracción del volumen molar. Las mezclas de triglicéridos presentan importantes desviaciones con respecto a la Idealidad del volumen molar. Los ajustes obtenidos para los valores del volumen molar frente a la temperatura son aceptables, determinándose los valores del coeficiente de dilatación volumétrica a presión constante de las mezclas estudiadas. Igualmente se ha estudiado el ajuste de los resultados experimentales de viscosidad a dos ecuaciones de predicción: una del tipo aditiva y otra del tipo parabólico.

  9. Endodontic treatment of a maxillary second molar with developmental anomaly: a case report.

    Science.gov (United States)

    Asgary, Saeed

    2007-01-01

    Fusion is a rare occurrence in molar teeth. The purpose of this rare case presentation is to describe the nonsurgical endodontic treatment of maxillary molar. A 28-year-old patient was referred for endodontic treatment of her chronic apical abscess of right maxillary second molar. In the clinical examination, a sinus tract adjacent to involved tooth and a small crown of supernumerary tooth fused to the buccal surface of the molar at gingival margin was observed. Endodontic treatment was decided for the involved molar for functional reason. Recall examination, a year after completion of endodontic and restorative treatments, showed the tooth was clinically asymptomatic and there was no radiographic lucency around the apical region.

  10. Patterns of third-molar agenesis and associated dental anomalies in an orthodontic population.

    Science.gov (United States)

    Celikoglu, Mevlut; Bayram, Mehmet; Nur, Metin

    2011-12-01

    The aim of this study was to investigate the frequency of dental anomalies in orthodontic patients with different patterns of third-molar agenesis, comparing them with patients without third-molar agenesis. A sample of 374 patients with agenesis of at least 1 third molar was divided into 4 groups according to the third-molar agenesis pattern, and a control group of 98 patients without third-molar agenesis was randomly selected from the patient archives. Panoramic radiographs and cast models were used to determine the associated dental anomalies, such as hypodontia, hyperdontia, impaction, dilaceration, microdontia, ectopic eruption, transposition, and transmigration. The Pearson chi-square and Fisher exact tests were used to determine the differences in the distribution of the associated dental anomalies among the groups. The prevalence of agenesis of other teeth (11.2%, n = 42) was significantly greater in our study sample (groups 1-4) than in the control group (group 5) (4.1%, n = 4; P dental anomalies in patients with agenesis of 3 and 4 third molars compared with the control group. Permanent tooth agenesis, microdontia of maxillary lateral incisors, and total dental anomalies are more frequently associated with agenesis of 4 third molars than with the presence of third molars. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  11. Elongational viscosity of narrow molar mass distribution polystyrene

    DEFF Research Database (Denmark)

    Bach, Anders; Almdal, Kristoffer; Rasmussen, Henrik Koblitz

    2003-01-01

    Transient and steady elongational viscosity has been measured for two narrow molar mass distribution polystyrene melts of molar masses 200 000 and 390 000 by means of a filament stretching rheometer. Total Hencky strains of about five have been obtained. The transient elongational viscosity rises...... above the linear viscoelastic prediction at intermediate strains, indicating strain hardening. The steady elongational viscosities are monotone decreasing functions of elongation rate. At elongation rates larger than the inverse reptation time, the steady elongational viscosity scales linearly...

  12. Endodontic Treatment of a Maxillary Second Molar with Developmental Anomaly: A Case Report

    OpenAIRE

    Asgary, Saeed

    2007-01-01

    Fusion is a rare occurrence in molar teeth. The purpose of this rare case presentation is to describe the nonsurgical endodontic treatment of maxillary molar. A 28-year-old patient was referred for endodontic treatment of her chronic apical abscess of right maxillary second molar. In the clinical examination, a sinus tract adjacent to involved tooth and a small crown of supernumerary tooth fused to the buccal surface of the molar at gingival margin was observed. Endodontic treatment was decid...

  13. Standard molar enthalpies of formation of 2-, 3- and 4-cyanobenzoic acids

    International Nuclear Information System (INIS)

    Ribeiro da Silva, Manuel A.V.; Amaral, Luisa M.P.F.; Boaventura, Cristina R.P.; Gomes, Jose R.B.

    2008-01-01

    The standard (p 0 = 0.1 MPa) molar enthalpies of formation of 2-, 3- and 4-cyanobenzoic acids were derived from their standard molar energies of combustion, in oxygen, at T = 298.15 K, measured by static bomb combustion calorimetry. The Calvet high temperature vacuum sublimation technique was used to measure the enthalpies of sublimation of 2- and 3-cyanobenzoic acids. The standard molar enthalpies of formation of the three compounds, in the gaseous phase, at T = 298.15 K, have been derived from the corresponding standard molar enthalpies of formation in the condensed phase and standard molar enthalpies for phase transition. The results obtained are -(150.7 ± 2.0) kJ . mol -1 , -(153.6 ± 1.7) kJ . mol -1 and -(157.1 ± 1.4) kJ . mol -1 for 2-cyano, 3-cyano and 4-cyanobenzoic acids, respectively. Standard molar enthalpies of formation were also estimated by employing two different methodologies: one based on the Cox scheme and the other one based on several different computational approaches. The calculated values show a good agreement with the experimental values obtained in this work

  14. Volumetric, acoustic and viscometric behaviour of dipotassium hydrogen phosphate and disodium hydrogen phosphate in aqueous solution of N-acetyl glycine at different temperatures

    International Nuclear Information System (INIS)

    Kumar, Harsh; Singla, Meenu; Mittal, Heena

    2016-01-01

    Highlights: • Densities, speeds of sound, viscosities of phosphate salts in aqueous N-acetyl glycine. • Large values of partial molar volume for dipotassium hydrogen phosphate. • Partial molar volume of transfer are positive for phosphate salts. • Positive B-coefficient values indicate ion–solvent interactions. - Abstract: Densities, speeds of sound and viscosities of dipotassium hydrogen phosphate (DPHP) and disodium hydrogen phosphate (DSHP) in aqueous solutions of N-acetyl glycine (AcGly) are reported at different temperatures. Densities and speeds of sound have been used to calculate apparent molar volume, apparent molar isentropic compression, partial molar volume, partial molar isentropic compression, partial molar volume of transfer, partial molar isentropic compression of transfer and partial molar expansivity. Pair and triplet interaction coefficients have also been calculated. Experimental viscosities have been used to determine B-coefficients. Further pair and triplet interaction coefficients have also been calculated. The results are discussed in terms of solute–solvent interactions.

  15. C-shaped root canal in a maxillary first molar: a case report.

    Science.gov (United States)

    Yilmaz, Z; Tuncel, B; Serper, A; Calt, S

    2006-02-01

    This case report presents an unusual C-shaped root canal system in a maxillary first molar tooth. Although C-shaped root canals are most frequently seen in the mandibular second molar, they may also appear in maxillary molars. A literature search revealed only a few case reports of C-shaped root canal systems in maxillary molars. The present case describes a C-shaped canal in the buccal root of a maxillary first molar. The endodontic access cavity displayed two canal orifices, one leading to the canal system in the buccal root, the other into the palatal root canal system. In the buccal root, what appeared to be the mesial and distal canals joined to form a single C-shaped canal. --Careful examination of radiographs and the internal anatomy of teeth is essential.-- The location and morphology of root canals should be identified at high magnification under the microscope.

  16. Use of palatally inserted mini-screw for upper molar distalization: A case series

    Directory of Open Access Journals (Sweden)

    Valliollah Arash

    2015-09-01

    Full Text Available  Abstract Reports have shown that molars can be distalized successfully with virtually no orthodontic anchorage loss with an intraosseous anchorage, even with fully erupted second molars. The purpose of this study was evaluating the effects of mini-screws as skeletal anchorage for upper molar distalization. In this case series, three patients needing maxillary first molar distalization, were selected. mini-screw was inserted in the anterior part of the palate. The screws were anchored to the first premolars by transpalatal arch and immediately loaded (150-160 g by 0.018-inch arch-wire and steel open-coil spring to distalize maxillary molars. The skeletal and dental changes were measured on cephalograms obtained before and after distalization. The amount of first molar distalization in the patients was 4 mm with 2°of tipping, 4 mm with 5°of tipping, and 3.5 mm with 2°of tipping respectively. Upper incisors and first premolars were stable during distalization.       

  17. Molar incisor hypomineralisation: clinical management of the young patient.

    LENUS (Irish Health Repository)

    Daly, Dympna

    2009-04-01

    Molar incisor hypomineralisation (MIH) is a common developmental condition resulting in enamel defects in first permanent molars and permanent incisors. It presents at eruption of these teeth. Early diagnosis is essential since rapid breakdown of tooth structure may occur, giving rise to acute symptoms and complicated treatment. The purpose of this article is to review MIH and illustrate its clinical management in young children.

  18. [Effects of removable partial dentures on the quality of life in people with shortened dental arches].

    Science.gov (United States)

    Armellini, D B; Heydecke, G; Witter, D J; Creugers, N H J

    2009-12-01

    In order to assess the enhanced value of removable partial dentures on the quality of life, patients at 2 university clinics were screened for the presence of complete or shortened dental arches. Those selected were assigned to 1 of 5 subgroups: 1) a shortened dental arch with all frontal teeth, 2) a shortened dental arch with one or more frontal diastemas, 3) a shortened dental arch with all frontal teeth, restored by a removable partial denture, 4) a shortened dental arch and several diastemas, restored by a removable partial denture, 5) a complete dental arch. The participants completed the Oral Health Impact Profile (OHIP-49) and the Short Form Health Survey (SF-36). Clinical data recorded were: whether any teeth were missing and if so which, whether or not these had been replaced by a removable partial denture, and the number of occluding pairs of (pre)molars. The results revealed that a shortenend dental arch has a certain impact on the quality of life. However, the participants only experienced benefits from a removable partial denture if the denture also replaced frontal teeth.

  19. MMP20 Overexpression Disrupts Molar Ameloblast Polarity and Migration.

    Science.gov (United States)

    Shin, M; Chavez, M B; Ikeda, A; Foster, B L; Bartlett, J D

    2018-02-01

    Ameloblasts responsible for enamel formation express matrix metalloproteinase 20 (MMP20), an enzyme that cleaves enamel matrix proteins, including amelogenin (AMELX) and ameloblastin (AMBN). Previously, we showed that continuously erupting incisors from transgenic mice overexpressing active MMP20 had a massive cell infiltrate present within their enamel space, leading to enamel mineralization defects. However, effects of MMP20 overexpression on mouse molars were not analyzed, although these teeth more accurately represent human odontogenesis. Therefore, MMP20-overexpressing mice ( Mmp20 +/+ Tg + ) were assessed by multiscale analyses, combining several approaches from high-resolution micro-computed tomography to enamel organ immunoblots. During the secretory stage at postnatal day 6 (P6), Mmp20 +/+ Tg + mice had a discontinuous ameloblast layer and, unlike incisors, molar P12 maturation stage ameloblasts abnormally migrated away from the enamel layer into the stratum intermedium/stellate reticulum. TOPflash assays performed in vitro demonstrated that MMP20 expression promoted β-catenin nuclear localization and that MMP20 expression promoted invasion through Matrigel-coated filters. However, for both assays, significant differences were eliminated in the presence of the β-catenin inhibitor ICG-001. This suggests that MMP20 activity promotes cell migration via the Wnt pathway. In vivo, the unique molar migration of amelogenin-expressing ameloblasts was associated with abnormal deposition of ectopic calcified nodules surrounding the adherent enamel layer. Enamel content was assessed just prior to eruption at P15. Compared to wild-type, Mmp20 +/+ Tg + molars exhibited significant reductions in enamel thickness (70%), volume (60%), and mineral density (40%), and MMP20 overexpression resulted in premature cleavage of AMBN, which likely contributed to the severe defects in enamel mineralization. In addition, Mmp20 +/+ Tg + mouse molar enamel organs had increased levels

  20. Space loss following premature loss of primary second molars.

    Science.gov (United States)

    Alnahwi, Hassan H; Donly, Kevin J; Contreras, Claudia I

    2015-01-01

    This study was designed to evaluate the amount of space loss (SL) caused by premature loss of primary second molars, determine whether the eruption status of permanent first molars is an important factor in the amount of SL, and evaluate the effectiveness of space maintainers (SMs) in SL prevention. SL associated with 100 prematurely extracted primary second molars was evaluated in 87 healthy patients. Teeth were divided into groups based on the use of SMs (36 with SM and 64 without SM). Bitewing and periapical radiographs taken before extraction and 6, 12, 24, 36, and 48 months after extraction were used to determine the amount of SL. Not every patient attended every recall appointment, so the sample size varied at different evaluation times. The most significant amount of SL occurred in the first 12 months after extraction. In patients who did not use an SM, at 6 months there was a mean SL of 2.12 mm (SD, 1.65 mm) and at 12 months there was a mean of 4.02 mm (SD, 1.65), with significantly more SL in the first 6 months (P 0.05). When patients without an SM were grouped by the eruption status of the permanent first molar, there was significantly more SL in the groups with unerupted first molars than there was in the groups with erupted first molars at both 6 months (P < 0.001) and 12 months (P < 0.05). At both 6 and 12 months, the amount of SL in patients who had an SM (n = 13 and n = 14, respectively) was not significantly different from the amount of SL in those who did not have an SM (n = 33 and n = 23, respectively). SMs should be placed as soon as possible following tooth extraction to prevent undue SL. Placement of an SM a year or more after extraction has minimal benefit, since most SL takes place within the first year. SL does occur even when SMs are used.

  1. Roentgenographic studies on the growth and development of lower third molars in Korean female

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hyoung Soon; Lee, Sung Woo [Department of Dental Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1976-11-15

    The author obtained the following results through the studies on 1012 roentgenograms of lower third molar regions of Korean female; 1. The rate of presence of lower third molars was 78.9 percent. 2. The period that crowns of lower third molars become completed was 16.1 years. 3. The period that completion of apices of lower third molars become completed was over 27 years.

  2. Molar Volume Analysis of Molten Ni-Al-Co Alloy by Measuring the Density

    Institute of Scientific and Technical Information of China (English)

    XIAO Feng; FANG Liang; FU Yuechao; YANG Lingchuan

    2004-01-01

    The density of molten Ni-Al-Co alloys was measured in the temperature range of 1714~1873K using a modified pycnometric method, and the molar volume of molten alloys was analyzed. The density of molten Ni-Al-Co alloys was found to decrease with increasing temperature and Co concentration in alloys. The molar volume of molten Ni-Al-Co alloys increases with increasing Co concentration in alloys. The molar volume of molten Ni-Al-Co alloys shows a negative deviation from the linear molar volume.

  3. Maxillary First Molars with 2 Distobuccal Canals: A Case Series.

    Science.gov (United States)

    Fogel, Howard M; Cunha, Rodrigo Sanches

    2017-11-01

    An appreciation of the anatomic complexity of the root canal system is essential at every step of endodontic treatment. Endodontic treatment of teeth with unusual root canal anatomy presents a unique challenge. Eight patients underwent nonsurgical root canal treatment of 3-rooted maxillary first molars in a specialty endodontic private practice. Four cases of Weine type II and 4 cases of Weine type III canal configurations in the distobuccal root of maxillary first molars were presented.This article highlighted an uncommon anatomic variation of 2 canals in the distobuccal root of the maxillary first molar. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. C-reactive protein a better indicator of inflammation after third molar ...

    African Journals Online (AJOL)

    operative pain and pre-operative levels of C-reactive and post-operative pain and swelling in impacted third molar surgery. Materials and Methods: In this prospective study subjects were patients indicated for mandibular third molar extraction.

  5. Two-rooted maxillary first molars with two canals: a case series.

    Science.gov (United States)

    Shakouie, Sahar; Mokhtari, Hadi; Ghasemi, Negin; Gholizadeh, Seddigheh

    2013-01-01

    Thorough understanding of the anatomic and internal morphology of a root canal system is absolutely essential for the success of endodontic treatment. Since permanent maxillary first molars have shown variation in internal anatomy, morphology, this tooth has been reviewed extensively. Presence of two canals in a two-rooted maxillary first molar has rarely been reported in studies describing tooth and root canal anatomies. In this report, three cases are presented, which involve the root canal treatment of maxillary first molars with fusion of the two buccal roots.

  6. Morphology of the Physiological Apical Foramen in Maxillary and Mandibular First Molars.

    Science.gov (United States)

    Abarca, J; Zaror, C; Monardes, H; Hermosilla, V; Muñoz, C; Cantin, M

    2014-06-01

    Information regarding the anatomy of the physiological apical foramen is limited. Knowing its diameter and shapes contributes to clinical work, specifically to the cleaning and shaping of the apical third. The aim of this ex vivo study was to determine the minimum and maximum diameters and shape of the physiological apical foramen in the roots of maxillary and mandibular first molars. A descriptive study was conducted on 89 recently extracted first molars. Roots 3-5 mm from the apex were sectioned and prepared for analysis at 40× magnification. The minimum and maximum diameters of each physiological foramen were measured using the program Motic Images plus 2.0 ML. The shape of the foramina, classified as round, oval or irregular, was determined by the difference between the maximum and minimum diameters. A total of 174 physiological foramina were analyzed. The average of the minimum and maximum diameters was between 0.24-0.33 mm in maxillary first molars and between 0.25-0.33 mm in mandibular first molars. In maxillary molars, the most common shape of the foramen was oval (50%), then irregular (32%), then round (18%). In mandibular molars, the oval shape was also the most frequent (59%), followed by irregular (23%) and round (18%). The findings of this study regarding the morphology of physiological apical foramina in first molars make it easier for the operator to choose the appropriately-sized instruments to perform endodontic therapy successfully.

  7. Morphology of the Physiological Apical Foramen in Maxillary and Mandibular First Molars

    Science.gov (United States)

    Abarca, J.; Zaror, C.; Monardes, H.; Hermosilla, V.; Muñoz, C.; Cantin, M.

    2015-01-01

    SUMMARY Information regarding the anatomy of the physiological apical foramen is limited. Knowing its diameter and shapes contributes to clinical work, specifically to the cleaning and shaping of the apical third. The aim of this ex vivo study was to determine the minimum and maximum diameters and shape of the physiological apical foramen in the roots of maxillary and mandibular first molars. A descriptive study was conducted on 89 recently extracted first molars. Roots 3–5 mm from the apex were sectioned and prepared for analysis at 40× magnification. The minimum and maximum diameters of each physiological foramen were measured using the program Motic Images plus 2.0 ML. The shape of the foramina, classified as round, oval or irregular, was determined by the difference between the maximum and minimum diameters. A total of 174 physiological foramina were analyzed. The average of the minimum and maximum diameters was between 0.24–0.33 mm in maxillary first molars and between 0.25–0.33 mm in mandibular first molars. In maxillary molars, the most common shape of the foramen was oval (50%), then irregular (32%), then round (18%). In mandibular molars, the oval shape was also the most frequent (59%), followed by irregular (23%) and round (18%). The findings of this study regarding the morphology of physiological apical foramina in first molars make it easier for the operator to choose the appropriately-sized instruments to perform endodontic therapy successfully. PMID:25937698

  8. Relationship of third molar movement during orthodontic treatment and root angulation

    Directory of Open Access Journals (Sweden)

    Morteza Oshagh

    2012-01-01

    Conclusion: The relation between the amount of third molar movement and its root angulation was not statistically significant. Therefore movement of third molars during orthodontic treatment should not be assumed as an etiologic factor of root angulations.

  9. Histopathologic Evaluation of Follicular Tissues Associated with Impacted Third Molars

    Directory of Open Access Journals (Sweden)

    M. Khorasani

    2008-06-01

    Full Text Available Objective: The aim of the present study was to histopathologically evaluate follicular tissues of third molars with pericoronal radiolucenciesof less than 2 millimeters.Materials and Methods: In this descriptive analytic study, 100 impacted third molars with normal follicular spaces were removed and their pericoronaltissues submitted for histopathologic examination. Different characteristicsof the epithelium and connective tissue were evaluated in all cases. Statisti-cal analysis was performed using chi square and Mann-Whitney tests.Results: In our study sample, 74% of the patients were female and 26% were male, ranging in age from 13 to 54 years (mean, 25.3 years. Lining epithelium was observed in 69% of the specimens of which 31%, 23% and 14% was cuboidal, squamous and columnar, respectively. A significant re-lationship was found between the presence of squamous epithelium and pa-tient age (P<0.05. Nonspecific chronic inflammation was the only patho-logic finding observed in 44% of the specimens. Inflammation was signifi-cantly associated with age and squamous metaplasia (P<0.05.Conclusion: Considering that pathologic lesions were not observed in anyof the studied cases, unerupted third molars should not be removed unless there is a clinical indication to do so, or in case the impacted molar shows evidence of pathological changes. Follow-up is suggested for asympto-matic impacted third molars.

  10. Lingual nerve injury following surgical removal of mandibular third molar

    Directory of Open Access Journals (Sweden)

    Abduljaleel Azad Samad

    2017-12-01

    Full Text Available Background and objective: The close proximity of lingual nerve in relation to the lingual cortical bone of the posterior mandibular third molar is clinically important because lingual nerve may be subjected to trauma during surgical removal of the impacted lower third molar. This prospective study aimed to evaluate the incidence of lingual nerve paresthesia following surgical removal of mandibular third molar in College of Dentistry, Hawler Medical University. Methods: A total of 116 third molars surgery were carried out under local anesthesia for 116 patients for removal of lower mandibular teeth Using Terence Ward's incision made in all cases, and after that, the buccal flap was reflected, lingual tissues had been retracted during bone removal with a periosteal elevator. The sensory disturbance was evaluated on the 7th postoperative day by standard questioning the patients: “Do you have any unusual feeling in your tongue, lingual gingiva and mucosa of the floor of the mouth?" Results: One patient experienced sensory disturbance, the lingual nerve paresthesia incidence was 0.9% as a transient sensory disturbance, while no patient of permanent sensory disturbance. Conclusion: The incidence of injury to the lingual nerve can be minimized by careful clinical evaluation, surgeon’s experience, surgical approach and knowledge about anatomical landmarks during surgical removal of an impacted lower third molar tooth.

  11. Standard molar enthalpies of formation of 2-, 3-, and 4-piperidinomethanol isomers

    International Nuclear Information System (INIS)

    Ribeiro da Silva, Manuel A.V.; Cabral, Joana I.T.A.

    2006-01-01

    The standard (p o =0.1MPa) molar energies of combustion in oxygen of 2-piperidinemethanol, 3-piperidinemethanol, and 4-piperidinemethanol, all in the crystalline phase, were measured, at T=298.15K, by static bomb calorimetry. These values were used to derive the standard molar enthalpies of combustion and the standard molar enthalpies of formation, in the condensed phase, for these compounds. Further, the standard molar enthalpies of sublimation, at T=298.15K, of these three piperidinomethanol isomers were determined by Cavet microcalorimetry. The combustion calorimetry results together with those from the Calvet microcalorimetry, were used to derive the standard molar enthalpies of formation, at T=298.15K, in the gaseous phase, of the three piperidinemethanol studied. -Δ c H m o (cr)Δ cr g H m o kJ.mol -1 kJ.mol -1 2-Piperidinemethanol3890.70+/-0.9293.02+/-0.503- Piperidinemethanol3895.3+/-1.195.9+/-1.44-Piperidinemethanol3891.3+/- 1.198.31+/-0.69

  12. In vitro evaluation of an alternative method to bond molar tubes

    Directory of Open Access Journals (Sweden)

    Célia Regina Maio Pinzan-Vercelino

    2011-02-01

    Full Text Available Despite the advances in bonding materials, many clinicians today still prefer to place bands on molar teeth. Molar bonding procedures need improvement to be widely accepted clinically. OBJECTIVE: The purpose of this study was to evaluate the shear bond strength when an additional adhesive layer was applied on the occlusal tooth/tube interface to provide reinforcement to molar tubes. MATERIAL AND METHODS: Sixty third molars were selected and allocated to the 3 groups: group 1 received a conventional direct bond followed by the application of an additional layer of adhesive on the occlusal tooth/tube interface, group 2 received a conventional direct bond, and group 3 received a conventional direct bond and an additional cure time of 10 s. The specimens were debonded in a universal testing machine. The results were analyzed statistically by ANOVA and Tukey's test (α=0.05. RESULTS: Group 1 had a significantly higher (p0.05. CONCLUSIONS: The present in vitro findings indicate that the application of an additional layer of adhesive on the tooth/tube interface increased the shear bond strength of the bonded molar tubes.

  13. Variant root morphology of third mandibular molar in normal and ...

    African Journals Online (AJOL)

    The mandibular third molar poses a challenge to dental surgeons due to it's unpredictable morphology which leads to increased difficulty during its extraction. The root morphology of the third molar is considered to be the most variable in the human dentition. The study aims to document these variations which will be useful ...

  14. Management of periodontally compromised mandibular molar with Hemisectioning: A case report

    Directory of Open Access Journals (Sweden)

    Bandu Napte

    2014-01-01

    Full Text Available Introduction: Hemisection involves sectioning of a periodontally involved mandibular molar so as to remove the involved root and save the remaining tooth. This procedure helps in saving a tooth which otherwise would have been deemed for extraction. Hemisection refers to removal or separation of root with its accompanying crown portion of two-rooted teeth, most commonly mandibular molars. Method: In this case report, an advanced Endo-Perio lesion on a left mandibular first molar was successfully treated by root-canal treatment and hemisection. This procedure helps preserve the tooth structure, alveolar bone and promote cost savings over other treatment options. Conclusion: Hemisection is a treatment option for saving a mandibular molar which is in advanced stage of periodontal disease of one root. Removal of the affected root will help in retaining the remaining tooth structure.

  15. Molar incisor hypomineralization: Considerations about treatment in a controlled longitudinal case

    Directory of Open Access Journals (Sweden)

    Daniela Cristina de Oliveira

    2015-01-01

    Full Text Available Molar incisor hypomineralization (MIH is a defect in the tooth enamel of systemic origin and may affect one or all four first permanent molars frequently associated with the permanent incisors. This case reports a 7-year-old child with severe MIH in the permanent molars associated with tooth decay and intense pain. In the first stage of treatment, therapy was performed with fluoride varnish and restoration with glass ionomer cement (GIC. After 6 years of clinical and radiographic follow-up, the restorations presented wear and fractures on the margins, indicating their replacement with composite resin. Severe cases of MIH in the early permanent molars can be treated with varnish and GIC to restore the patient′s comfort and strengthen the hypomineralized dental structures. The clinical and radiographic monitoring frequently indicated when the restoration with composite resin should be performed.

  16. Guide-Plane Retention in Designing Removable Partial Dentures.

    Science.gov (United States)

    Mothopi-Peri, Matshediso; Owen, C Peter

    To compare the influence of abutment teeth guide planes and guiding surfaces on retention of a removable partial denture (RPD). Extracted teeth embedded into a maxillary cast in the first premolar and second molar positions simulated two bounded saddles. Acrylic resin RPDs were made with no guide planes, then with guide planes, then with guiding surfaces added to directly contact the guide planes. The maximum loads on removal from the cast were recorded. There was a significant increase in retention force of 1.6 times when only guide planes were present and of 10.2 times when guiding surfaces intimately contacted the guide planes. The retention of acrylic resin RPDs can be substantially increased by making their guiding surfaces intimately contact the guide planes of the teeth.

  17. Approximal morphology as predictor of approximal caries in primary molar teeth

    DEFF Research Database (Denmark)

    Cortes, A; Martignon, S; Qvist, V

    2018-01-01

    consent was given, participated. Upper and lower molar teeth of one randomly selected side received a 2-day temporarily separation. Bitewing radiographs and silicone impressions of interproximal area (IPA) were obtained. One-year procedures were repeated in 52 children (84%). The morphology of the distal...... surfaces of the first molar teeth and the mesial surfaces on the second molar teeth (n=208) was scored from the occlusal aspect on images from the baseline resin models resulting in four IPA variants: concave-concave; concave-convex; convex-concave, and convex-convex. Approximal caries on the surface...

  18. Prevalence and Pattern of Third Molar Impaction; A retrospective study of radiographs in Oman

    Directory of Open Access Journals (Sweden)

    Samira M. Al-Anqudi

    2014-08-01

    Full Text Available Objectives: The aim of this retrospective study was to investigate the prevalence and pattern of third molar impaction in patients between 19‒26 years old attending Sultan Qaboos University Hospital (SQUH in Muscat, Oman. Methods: The study reviewed 1,000 orthopantomograms (OPGs of patients attending the Oral Health Department of SQUH between October 2010 and April 2011. Patients were evaluated to determine the prevalence of third molar impaction, angulation, level of eruption and associated pathological conditions. Results: Of the study population, 543 (54.3% OPGs showed at least one impacted third molar. The total number of impacted molars was 1,128. The most common number of impacted third molars was two (41%. The most common angulation of impaction in the mandible was the mesioangular (35% and the most common level of impaction in the mandible was level A. Of the 388 bilateral occurrences of impacted third molars, 377 were in the mandible. There was no significant difference in the frequency of impaction between the right and left sides of both jaws. Pathological conditions associated with impacted lower third molars were found in 18%, of which 14% were associated with a radiographic radiolucency of more than 2.5 mm, and 4% of impacted lower third molars were associated with dental caries. Conclusion: This study found that more than half of Omani adult patients ranging in age from 19‒26 years had at least one impacted third molar.

  19. Dental and skeletal changes after intraoral molar distalization with sectional jig assembly.

    Science.gov (United States)

    Gulati, S; Kharbanda, O P; Parkash, H

    1998-09-01

    The present study was conducted on 10 subjects to evaluate dental and skeletal changes after intraoral molar distalization. The maxillary molars were distalized with a sectional jig assembly. Sentalloy open coil springs were used to exert 150 gm of force for a period of 12 weeks. A modified Nance appliance was the main source of anchorage. The pre- and postdistalization records included dental study casts, clinical photographs, and cephalograms. A total of 665 readings recorded from lateral cephalograms and dental casts were subjected to statistical analysis. The mean distal movement of the first molar was 2.78 mm, which was highly significant (o < 0.001). It moved distally at the rate of 0.86 mm/month. There was clinically some distal tipping (3.50 degrees) and distopalatal rotation (2.40 degrees). These changes were statistically significant (p < 0.001). The second molars accompanied the first molars and moved distally by nearly the same amount. There was 1.00 mm increase in the overjet and 2.60 degrees mesial tip of second premolar. The changes in the facial skeleton and dentition bases were minimal and statistically not significant. However, there was clockwise rotation of the mandible of 1.30 degrees that was statistically significant. This was the result of molar extrusion (1.60 mm).

  20. Psychological impact of third molar surgery: a 1-month prospective study

    NARCIS (Netherlands)

    de Jongh, Ad; van Wijk, Arjen J.; Lindeboom, Jerome A.

    2011-01-01

    To prospectively examine the psychological impact of surgical third molar removal, and to identify possible psychological risk factors for the development of dental anxiety and symptoms of psychological trauma. Patients (N = 71) scheduled for surgical mandibular third molar removal were assessed

  1. Study of pulp chamber morphology of primary mandibular molars using spiral computed tomography.

    Science.gov (United States)

    Selvakumar, Haridoss; Kavitha, Swaminathan; Vijayakumar, Rajendran; Eapen, Thomas; Bharathan, Rajendran

    2014-11-01

    The purpose of this study was to evaluate the pulp chamber morphology in primary mandibular molars using spiral computed tomography (SCT). Sixty extracted primary mandibular molars were scanned using SCT for the (i) distance between the central fissure to furcation, (ii) distance between the central fissure to the floor of the pulp chamber, (iii) height of the pulp chamber (roof-floor), (iv) distance between the floor of the pulp chamber to the furcation. The mean and standard deviation was analyzed using statistical package for the social sciences (SPSS) program. The results of this study show that the average mean distance from the central fissure to the floor of the pulp chamber is 5.07 mm in first mandibular primary molar and 5.54 mm in second mandibular primary molar. It can be concluded that the greatest depth to which a bur can go during access opening without perforating the furcation in first primary mandibular molar is 5.07 mm and 5.54 mm in second primary mandibular molar.

  2. The effect of heat treatment on the internal structure of nanostructured block copolymer films

    Energy Technology Data Exchange (ETDEWEB)

    Sepe, A; Hoppe, E T; Jaksch, S; Magerl, D; Zhong, Q; Papadakis, C M [Technische Universitaet Muenchen, Physikdepartment, Fachgebiet Physik weicher Materie/Lehrstuhl fuer funktionelle Materialien, James-Franck-Strasse 1, 85747 Garching (Germany); Perlich, J [HASYLAB at DESY, Notkestrasse 85, 22603 Hamburg (Germany); Posselt, D [IMFUFA, Department of Science, Systems and Models, Roskilde University, PO Box 260, 4000 Roskilde (Denmark); Smilgies, D-M, E-mail: papadakis@tum.de [Cornell High Energy Synchrotron Source (CHESS), Wilson Laboratory, Cornell University, Ithaca, NY 14853 (United States)

    2011-06-29

    We report on the temperature dependence of the nanostructure of thin block copolymer films, as studied using in situ grazing-incidence small-angle x-ray scattering (GISAXS). We focus on spin-coated poly(styrene-b-butadiene) diblock copolymer thin films featuring lamellae perpendicular to the substrate. In situ GISAXS measurements elucidate the structural changes during heat treatment at temperatures between 60 and 130 {sup 0}C. Thermal treatment below 100 {sup 0}C does not destroy the perpendicular lamellar order. In contrast, treatment between 105 and 120 {sup 0}C leads to a broad distribution of lamellar orientations which only partially recovers upon subsequent cooling. Treatment at 130 {sup 0}C leads to severe changes of the film structure. We attribute the change of behavior at 100 {sup 0}C to the onset of the glass transition of the polystyrene block and the related increase of long-range mobility. Our results indicate that the perpendicular lamellar orientation for high molar mass samples is not stable under all conditions.

  3. Temporal abscess after third molar extraction in the mandible.

    Science.gov (United States)

    de Oliveira Neto, Patrício José; de Souza Maliska, Maximiana Cristina; Sawazaki, Renato; Asprino, Luciana; de Moraes, Márcio; Moreira, Roger William Fernandes

    2012-03-01

    Dental infections resulting before or after third molar removal are complications in which the maxillofacial surgeon may have to initiate an earlier management. The severe dental infections resulting before or after this procedure is one of the few life-threatening complications in which the maxillofacial surgeon may have to initiate an earlier management. Infections involving the temporal space are rare and infrequently reported. Infections in this space have also been observed secondary to maxillary sinusitis, maxillary sinus fracture, temporomandibular arthroscopy, and drug injection, although more commonly associated to third molar infections. A 22-year-old man had undergone extraction of tooth 38 secondary to pericoronaritis by a general dentist. Physical examination of his face demonstrated severe trismus, pain, and swelling in temporal region. A CT scan showed an inflammatory area into the temporal space. He was started on IV cephalosporin, but the clinical course of the patient was not satisfactory. Incision and drainage were performed from an extraoral and intraoral approach. After discharged, the antibiotic was switched to clindamycin IO 600 mg. The retromaxillary and temporal infections are quite common after maxillary molar extractions but not after mandibular third molar, the spread mechanism of ascension must be involved with the virulence of microorganisms, but more studies are necessary to clarify this occurrence.

  4. X-RAY MEASUREMENTS OF IMPACTED MANDIBULAR THIRD MOLARS

    Directory of Open Access Journals (Sweden)

    Petya G. Kanazirska

    2017-03-01

    Full Text Available The X-ray diagnostics is essential in case of retention of teeth. An important condition for proper treatment plan for impacted third molars of the mandible is the determination of the type of retention in the jaw in accordance with their medio-distal inclination and the space available for eruption (retromolar space. Purpose: The purpose of this article is to present an objective method for determination of the medio-distal inclination and the space for eruption of the third molars of the mandible. Materials and methods: The studied patients with impacted third molars of the mandible are 127, aged 17 through 60. They were examined with Cone-beam Computed Tomography (CBCT. On the orthopantomography, obtained after the scanning as a reconstructed image, we defined the medio-distal inclination and space for eruption of the third molars of the mandible. For this purpose, we summarized several methods. Results: The most common inclination of the third molars of the mandible with retained eruption is the medial one at 120 teeth (61.5% ± 3.5. Second in frequency is the vertical one-34 teeth (17.4% ± 2.7, followed by the distal inclination– 21 teeth (10.8% ± 2.2. With the lowest frequency are the teeth which are positioned horizontally –20 teeth (10.3% ± 2.2. Shortage of retromolar space is established for173 teeth (88.7% ± 2.3. In 22 teeth (11.3% ± 2.3 there is enough space in the jaw for eruption. Conclusion: An objective method for determination of the medio-distal inclination of the teeth and the space available for eruption is introduced for the first time in Bulgaria. By determining the inclination of impacted wisdom teeth under this methodology one can avoid the subjective factor–the seventh tooth. It is not a reference plane, because it can also be tilted or missing. With the help of the developed method the retromolar point can be determined more objectively.

  5. Signal mediators at induction of heat resistance of wheat plantlets by short-term heating

    Directory of Open Access Journals (Sweden)

    Yu. V. Karpets

    2015-12-01

    Full Text Available The effects of functional interplay of calcium ions, reactive oxygen species (ROS and nitric oxide (NO in the cells of wheat plantlets roots (Triticum aestivum L. at the induction of their heat resistance by a short-term influence of hyperthermia (heating at the temperature of 42 °С during 1 minute have been investigated. The transitional increase of NO and H2O2 content, invoked by heating, was suppressed by the treatment of plantlets with the antagonists of calcium EGTA (chelator of exocellular calcium, lanthanum chloride (blocker of calcium channels of various types and neomycin (inhibitor of phosphatidylinositol-dependent phospholipase C. The rise of hydrogen peroxide content, caused by hardening, was partially suppressed by the action of inhibitors of nitrate reductase (sodium wolframate and NO-synthase (NG-nitro-L-arginine methyl ester – L-NAME, and the increasing of nitric oxide content was suppressed by the treatment of plants with the antioxidant ionol and with the scavenger of hydrogen peroxide (dimethylthiourea. These compounds and antagonists of calcium also partially removed the effect of the rise of plantlets’ heat resistance, invoked by hardening heating. The conclusion on calcium’s role in the activation of enzymatic systems, generating reactive oxygen species and nitric oxide, and on the functional interplay of these signal mediators at the induction of heat resistance of plantlets by hardening heating is made.

  6. Using cone beam computed thomography in planning the extraction of impacted third molars

    Directory of Open Access Journals (Sweden)

    Vlahović Zoran

    2016-01-01

    Full Text Available The panoramic radiography is the most used diagnostic imaging method in planning impacted lower third molar extractions. However, often panoramic radiography does not provide enough information in treatment planning for performing safely surgical extraction of impacted third molars. CBCT (Cone beam computed tomography provides more precise information in diagnostic analysis especially for planning surgical procedures where complications can be expected due to close relationship between mandibular canal and lower impacted third molars. The aim of this study is comparative analysis of panoramic radiography and CBCT in evaluating the topographic relationship between mandibular canal and impacted third molars. The study included 50 patients with close relationship between mandibular canal and impacted third molars detected using panoramic radiography. After panoramic radiography analysis CBCT was performed in order to diagnose, plan and prevent complications during the surgical tooth extraction. CBCT examination considered comparative analysis with panoramic radiography, marking, volume rendering and assessment of mandibular canal in buccolingual direction. Out of total patients where suprimposition of mandibular canal and impacted third molar on panoramic radiography was detected, in 32 patients mandibular chanal was localised on lingual side. Mandibular canal was positioned at bucal side in 18 of 50 patients. Results of this research indicate that panoramic radiography can be useful in everyday practice for diagnosis, planning and preparing lower third molar extractions, but in cases where close relationship between mandibular canal and lower third molars is detected CBCT is recommended as more precise radiographic imaging method in order to prevent complications.

  7. Subcutaneous emphysema during third molar surgery: a case report

    OpenAIRE

    Romeo, Umberto; Galanakis, Alexandros; Lerario, Francesco; Daniele, Gabriele Maria; Tenore, Gianluca; Palaia, Gaspare

    2011-01-01

    Extraction of third molars is the most common surgical procedure performed in oral surgery on a daily basis and, despite surgical skills and expertise, complications may occur. Complications observed during or after third molar removal may include pain, swelling, bleeding, infection, sinus perforation and nerve damage. Fortunately, with a proper management and a good surgical technique, the incidence of such events is low. Subcutaneous emphysema associated with dental extraction occurs when t...

  8. Molar incisor hypomineralization: current research evidences

    Directory of Open Access Journals (Sweden)

    Manikandan Ekambaram

    2016-06-01

    Full Text Available Molar-Incisor Hypomineralization (MIH is a condition of systemic origin that involves one to four first permanent molar teeth and often associated with affected incisors. Although several associations to prenatal/perinatal childhood medical conditions have been reported, the etiology of MIH still remains unclear. The degree of enamel hypomineralization in the affected teeth can vary and the clinical problems associated with the teeth include increased susceptibility to caries, rapid wear, and post-eruptive enamel breakdown. Affected teeth are extremely challenging to treat as the enamel is porous, sensitive and treating clinicians might encounter great difficulty in achieving profound anaesthesia. The first part of thispresentation will give an update on prevalence, potential etiological factors, and management strategies of this condition. The second part of the presentation will cover a systematic review results on bonding strategies to hypomineralized enamel.

  9. Molar mass of poly(ethylene terephthalate) (PET) during ultimate uniaxial drawing

    NARCIS (Netherlands)

    Göschel, U.; Cools, P.J.C.H.

    2000-01-01

    The changes of the average molar mass Mw, Mn, Mz, and molar mass distributions during multistep uniaxial drawing of poly(ethylene terephthalate) (PET) to achieve ultimate mechanical properties have been studied in detail by means of size exclusion chromatography (SEC) with triple detection:

  10. Molar-Mass of Poly(Ethylene-Terephthalate) (PET) During Ultimate Uniaxial Drawing

    NARCIS (Netherlands)

    Göschel, A.G.P.U.; Cools, P.J.C.H.

    2000-01-01

    The changes of the average molar mass Mw, Mn, Mz, and molar mass distributions during multistep uniaxial drawing of poly(ethylene terephthalate) (PET) to achieve ultimate mechanical properties have been studied in detail by means of size exclusion chromatography (SEC) with triple detection:

  11. Micro-CT analyses of apical enlargement and molar root canal complexity

    DEFF Research Database (Denmark)

    Markvart, Merete; Darvann, Tron Andre; Larsen, Per

    2012-01-01

    AIM: To compare the effectiveness of two rotary hybrid instrumentation techniques with focus on apical enlargement in molar teeth and to quantify and visualize spatial details of instrumentation efficacy in root canals of different complexity. METHODOLOGY: Maxillary and mandibular molar teeth wer...

  12. Prevalence of Third Molar Agenesis: Associated Dental Anomalies in Non-Syndromic 5923 Patients.

    Science.gov (United States)

    Sujon, Mamun Khan; Alam, Mohammad Khursheed; Rahman, Shaifulizan Abdul

    2016-01-01

    The aim of this study was to investigate the prevalence of third molar agenesis and other associated dental anomalies in Bangladeshi population and to investigate the relationship of other dental anomalies with the third molar presence/agenesis. A retrospective study was performed using panoramic radiographs of 5923 patients, who ranged in age from 10 to 50 years. All radiographs were analyzed by Planmeca Romexis® 3.0 software (Planmeca Oy, Helsinki, Finland). Pearson chi-square and one way ANOVA (Post Hoc) test were conducted. The prevalence of third molar agenesis was 38.4%. The frequency of third molar agenesis was significantly higher in females than males (p dental anomalies was 6.5%, among them hypodontia was 3.1%. Prevalence of third molar agenesis varies in different geographic region. Among the other dental anomalies hypodontia was more prevalent.

  13. Dispositivo de seguridad para controlar mejor el tercer molar impactado durante exodoncia: Una nueva técnica Security device for a better control of impacted third molars during exodontia: A new technique

    Directory of Open Access Journals (Sweden)

    F. Hernández Altemir

    2005-04-01

    Full Text Available El desplazamiento accidental del tercer molar impactado es una complicación que ocurre de vez en cuando durante la exodoncia. La recuperación de estos dientes accidentalmente desplazados puede ser compleja debido a la mala visibilidad y el espacio limitado. Describimos una técnica fácil basada en un sistema de anclaje para controlar mejor los terceros molares impactados durante la exodoncia.Accidental displacement of impacted third molars is a complication that occasionally occurs during exodontia. The retrieval of these accidentally displaced third molars may be complex due to poor visibility and limited space. We describe an easy technique for a better control of impacted third molars during exodontia based on an anchoring system.

  14. Four osteotomy methods with piezosurgery to remove complicated mandibular third molars: a retrospective study.

    Science.gov (United States)

    Ge, Jing; Yang, Chi; Zheng, Jia-Wei; He, Dong-Mei; Zheng, Ling-Yan; Hu, Ying-Kai

    2014-11-01

    Piezosurgery has been used widely in oral and maxillofacial surgery, but there has been no report systematically describing an osteotomy method with piezosurgery for complicated mandibular third molar removal. The aim of this study was to introduce 4 osteotomy methods using piezosurgery and evaluate their effects. A retrospective study was conducted of patients with a complicated impacted mandibular third molar requiring extraction. The predictor variable was the extraction technique. Four osteotomy methods using piezosurgery were tested according to different impaction types: method 1 involved complete bone removal; method 2 involved segmental bone removal; method 3 involved bone removal combined with tooth splitting; and method 4 involved block bone removal. Outcome variables were success rate, operative time, major complications (including nerve injury, mandible fracture, severe hematoma, or severe edema), and serious pyogenic infection. Data were analyzed using descriptive statistics. The study was composed of 55 patients with 74 complicated impacted mandibular third molars. All impacted mandibular third molars were removed successfully. The average surgical time was 15 minutes (range, 8 to 26 minutes). Thirty-eight molars (51.4%) were extracted by method 1, 18 molars (24.3%) by method 2, 12 molars (16.2%) by method 3, and 6 molars (8.1%) by method 4. Two cases (2.7%) developed postoperative infections and recovered within 1 week using drainage and antibiotic administration. The 4 osteotomy methods with piezosurgery provide effective ways of removing complicated impacted mandibular third molars. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Restorasi Resin Komposit Menggunakan Pasak Tapered Self Threading Pada Molar Ketiga Kiri Mandibula

    Directory of Open Access Journals (Sweden)

    Ellen Krisanti

    2013-06-01

    Composite Resin Restoration Using Tapered Self Threading Poston Left Mandibular Third Molar. Root canal morphology of mandibular third molar has more complex variation than the other molars. In third molar, the extraction teeth are often executed; however, the third molar can be maintained in other conditions. One visit root canal treatment is a therapy option for this case. The purpose of this case report is to show the success of one visit root canal treatment in third molar with pulp necrosis by restoring the composite resin through tapered self-treading post. A 20 year-old female patient who came to the Prof Soedomo RSGM, FKG UGM complained about the pain when chewing food on her third molar and positive in percussion. The radiographs showed that there was an incomplete restoration. There was a gap between cavities with restoration. The treatment plan for this case was one visit root canal treatment and composite resin with tapered self-threading post as final restoration. From the case, it can concluded that one visit root canal treatment results in a smaller chance for microorganism recontamination than the multi-visit in order to ensure the success of the treatment. Direct composite resin restoration with tapered self-threading dowel is an alternative restoration after endodontic treatment because it works out faster and more retentive.

  16. NO formation in the burnout region of a partially premixed methane-air flame with upstream heat loss

    Energy Technology Data Exchange (ETDEWEB)

    Mokhov, A.V.; Levinsky, H.B.

    1999-09-01

    Measurements of temperature and NO concentration in laminar, partially premixed methane-air flames stabilized on a ceramic burner in coflow are reported. The NO concentration and temperature were determined by laser-induced fluorescence (LIF) and coherent anti-Stokes Raman scattering (CARS), respectively. Upstream heat loss to the burner was varied by changing the exit velocity of the fuel-air mixture at a constant equivalence ratio of 1,3; this alters the structure of the flame from an axisymmetric Bunsen-type to a strongly stabilized flat flame. To facilitate analysis of the results, a method is derived for separating the effects of dilution from those of chemical reaction based on the relation between the measured temperature and the local mixture fraction, including the effects of upstream heat loss. Using this method, the amount of NO formed during burnout of the hot, fuel-rich combustion products can be ascertained. In the Bunsen-type flame, it is seen that {approximately}40 ppm of NO are produced in this burnout region, at temperatures between {approximately}2,100 K and {approximately}1,900 K, probably via the Zeldovich mechanism. Reducing the exit velocity of 12 cm/s reduces the flame temperature substantially, and effectively eliminates this contribution. At velocities of 12 and 8 cm/s, {approximately}10 ppm of NO are formed in the burnout region, even though the gas temperatures are too low for Zeldovich NO to be significant. Although the mechanism responsible for these observations is as yet unclear, the results are consistent with the idea that the low temperatures in the fuel-rich gases caused by upstream heat loss retard the conversion of HCN (formed via the Fenimore mechanism) to NO, with this residual HCN then being converted to NO during burnout.

  17. Immediate Placement of Ultrawide-Diameter Implants in Molar Sockets: Description of a Recommended Technique

    NARCIS (Netherlands)

    Hattingh, A.C.; Bruyn, H. de; Ackermann, A.; Vandeweghe, S.

    2018-01-01

    Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with

  18. Synthesis and Properties of Some polyurethane/ Partially Aromatic Polyester Casting Samples

    International Nuclear Information System (INIS)

    Sadek, E.M.; Mazroua, A.M.; Emam, A.S.; Motawie, A.M.

    2005-01-01

    A series of partially aromatic terephthalate polyesters were synthesized by melt transesterification of dimethyl terephthalate with various types of aliphatic diol compounds in 1:1.1 molar ratio. Ethylene-, di-, tri-, tetra ethylene glycol and polyethylene glycol with different molecular weights 1000, 4000, 6000 as well as the prepared dihydroxy natural rubber were used. Another series of partially aromatic adipate and sebacate polyesters based on the prepared bisphenol A and its tetrabromo derivative were also synthesized by direct polycondensation esterification with adipic and sebacic acid. Polyurethane with NCO/OH ratio equal 4 was prepared from the reaction of 2,4 toluene diisocyanate with polyethylene glycol 1000. The prepared polyurethane was mixed with different weight percentages (2, 4, 6, 8, 10 or 12 % w/w) of the prepared partially aromatic polyesters to give polyurethane/polyester compositions. Mechanical and electrical properties as well as water and chemical resistance of the prepared film samples with thickness 3-4 mm were determined and compared with those of polyurethane film sample without polyester. The data indicate that 10 % w/w of the added partially aromatic polyester increases polyurethane tensile strength, improves its insulation properties and hydrolytic stability as well as its chemical resistance. Film samples based on bisphenol A impart excellent properties as compared with those based on aliphatic glycol species and dihydroxy natural rubber. Keywords: Partially aromatic polyesters, Dimethyl terephthalate, Glycols, Bisphenol A, Tetrabromo bisphenol A, Natural rubber, Adipic acid, Sebacic acid, Polyurethane, Casting

  19. Ectopic Molar Pregnancy: Diagnostic Efficacy of Magnetic Resonance Imaging and Review of the Literature.

    Science.gov (United States)

    Yamada, Yasushi; Ohira, Satoshi; Yamazaki, Teruyuki; Shiozawa, Tanri

    2016-01-01

    Ectopic molar pregnancy is extremely rare, and preoperative diagnosis is difficult. Our literature search found only one report of molar pregnancy diagnosed preoperatively. Moreover, there is no English literature depicting magnetic resonance image (MRI) findings of ectopic molar pregnancy. We report a case of ectopic molar pregnancy preoperatively diagnosed using MRI. A literature review of 31 cases of ectopic molar pregnancy demonstrated that lesions have been found in the fallopian tube (19 cases, 61%), ovary (5 cases, 16%), cornu (3 cases, 10%), peritoneum (2 cases, 6%), uterine cervix (1 case, 3%), and cesarean scar (1 case, 3%). Abdominal pain and abnormal vaginal bleeding were reported in 70% and 61% of the patients, respectively. Twenty-one cases (67%) presented with rupture and hemoperitoneum. All patients underwent surgical resection or dilatation and curettage. Methotrexate therapy was performed in one case because residual trophoblastic tissue was suspected. A second operation was performed in one case of ovarian molar pregnancy because serum hCG levels increased again after primary focal ovarian resection. No patients developed metastatic disease or relapsed. These findings suggest the prognosis of ectopic molar pregnancy to be favorable.

  20. Ectopic Molar Pregnancy: Diagnostic Efficacy of Magnetic Resonance Imaging and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Yasushi Yamada

    2016-01-01

    Full Text Available Ectopic molar pregnancy is extremely rare, and preoperative diagnosis is difficult. Our literature search found only one report of molar pregnancy diagnosed preoperatively. Moreover, there is no English literature depicting magnetic resonance image (MRI findings of ectopic molar pregnancy. We report a case of ectopic molar pregnancy preoperatively diagnosed using MRI. A literature review of 31 cases of ectopic molar pregnancy demonstrated that lesions have been found in the fallopian tube (19 cases, 61%, ovary (5 cases, 16%, cornu (3 cases, 10%, peritoneum (2 cases, 6%, uterine cervix (1 case, 3%, and cesarean scar (1 case, 3%. Abdominal pain and abnormal vaginal bleeding were reported in 70% and 61% of the patients, respectively. Twenty-one cases (67% presented with rupture and hemoperitoneum. All patients underwent surgical resection or dilatation and curettage. Methotrexate therapy was performed in one case because residual trophoblastic tissue was suspected. A second operation was performed in one case of ovarian molar pregnancy because serum hCG levels increased again after primary focal ovarian resection. No patients developed metastatic disease or relapsed. These findings suggest the prognosis of ectopic molar pregnancy to be favorable.

  1. A Priori Regularity of Parabolic Partial Differential Equations

    KAUST Repository

    Berkemeier, Francisco

    2018-01-01

    In this thesis, we consider parabolic partial differential equations such as the heat equation, the Fokker-Planck equation, and the porous media equation. Our aim is to develop methods that provide a priori estimates for solutions with singular

  2. Excess molar volumes of binary mixtures (an ionic liquid + water): A review

    International Nuclear Information System (INIS)

    Bahadur, Indra; Letcher, Trevor M.; Singh, Sangeeta; Redhi, Gan G.; Venkatesu, Pannuru; Ramjugernath, Deresh

    2015-01-01

    Highlights: • Review of excess molar volumes for mixtures of (ionic liquids (ILs) + H 2 O). • 6 cation groups reviewed including imidazolium and pyrrolidinium groups. • 13 anions reviewed including tetraborate, triflate, and hydrogensulphate. • Effects of anion, cation, and temperature investigated. - Abstract: This review covers recent developments in the area of excess molar volumes for mixtures of {ILs (1) + H 2 O (2)} where ILs refers to ionic liquids involving cations: imidazolium, pyridinium, pyrrolidinium, piperidinium, morpholinium and ammonium groups; and anions: tetraborate, triflate, hydrogensulphate, methylsulphate, ethylsulphate, thiocyanate, dicyanamide, octanate, acetate, nitrate, chloride, bromide, and iodine. The excess molar volumes of aqueous ILs were found to cover a wide range of values for the different ILs (ranging from −1.7 cm 3 · mol −1 to 1.2 cm 3 · mol −1 ). The excess molar volumes increased with increasing temperature for all systems studied in this review. The magnitude and in some cases the sign of the excess molar volumes for all the aqueous ILs mixtures, apart from the ammonium ILs, were very dependent on temperature. This was particularly important in the dilute IL concentration region. It was found that the sign and magnitude of the excess molar volumes of aqueous ILs (for ILs with hydrophobic cations), was more dependent on the nature of the anion than on the cation

  3. Impaction of lower third molars and their association with age: radiological perspectives.

    Science.gov (United States)

    Ryalat, Soukaina; AlRyalat, Saif Aldeen; Kassob, Zaid; Hassona, Yazan; Al-Shayyab, Mohammad H; Sawair, Faleh

    2018-04-04

    Third molars are the most commonly impacted teeth, and their extraction is the most commonly performed procedure in oral and maxillofacial surgery. The aim of the present study is to describe the pattern of mandibular third molar impaction and to define the most appropriate age for prophylactic extraction of mandibular third molar teeth. A total of 1198 orthopantomographs (OPGs) with 1810 impacted lower third molars were reviewed by two authors. The pattern of eruption in relation to patient's age was examined using standard radiographic points and angles. Statistical analysis was performed using SPSS for Windows release 16.0 (SPSS Inc., Chicago, IL, USA). In patients older than 20 years, vertical pattern of impaction was the most common (21.4%); while in young patients; horizontal impaction was more common (21.3%). Furthermore, there was a constant pattern of increase in Pell-Gregory ramus class 1 with increasing age, as the prevalence of class 1 was 0% at age 18 years compared to 54.9% at the age of 26 years. Frequency of vertical impaction of lower third molars was seen more at an older age (> 20 years) in this study, with an increase in the retromolar space. Late extraction of mandibular third molar teeth (i.e. after the age of 20) is therefore recommended when prophylactic extraction is considered.

  4. Periodontal considerations in the use of bonds or bands on molars in adolescents and adults.

    Science.gov (United States)

    Boyd, R L; Baumrind, S

    1992-01-01

    This longitudinal study compared the periodontal status of bonded and banded molars in 20 adult and 40 adolescent patients before, during and after treatment with fixed orthodontic appliances. Plaque accumulation (measured by the Plaque Index), gingival inflammation (measured by the Gingival Index and the bleeding tendency), and pocket depth were assessed by one examiner at sites along the mesio-buccal line angle of the maxillary right first molar and the mandibular left first molar. Assessments were made immediately prior to the placement of fixed appliances (pretreatment), at 1, 3, 6, 9, 12 and 18 months after appliances were placed; and 3 months after appliances were removed (posttreatment). Loss of attachment between the pretreatment and posttreatment visits also was determined. At pretreatment, no significant differences were found in gingival inflammation between maxillary and mandibular banded and bonded molars. During treatment, both maxillary and mandibular banded molars showed significantly (p less than 0.05) greater gingival inflammation and plaque accumulation than did bonded molars. Three months after appliance removal, the maxillary molars that had been banded continued to show significantly more gingival inflammation and loss of attachment than did the maxillary molars that had been bonded. When all banded and bonded teeth were grouped by patient age, mean values for plaque accumulation and gingival inflammation in the maxillary molar regions were significantly greater for adolescents than for adults.

  5. Fracture Resistance of Pulpotomized Primary Molar Restored with Extensive Class II Amalgam Restorations

    Directory of Open Access Journals (Sweden)

    F. Mazhari

    2008-06-01

    Full Text Available Objective: The aim of the present study was to evaluate fracture resistance of pulpoto-mized primary molar teeth restored with extensive multisurface amalgam restorations.Materials and Methods: Eighty extracted carious human primary molar teeth were se-lected forpresent study. Teeth were divided in to eight groups of ten. Mesio- or disto-occlusal and Mesio-occluso-distal cavities with different cavity wall thickness (1.5 or 2.5mm were prepared in both first and second primary molar teeth. After restoring teeth with amalgam, all specimens were stored in distilled water at 37°C for 7 days. Then samples were thermocycled for 1000 cycles from 5°C to 55°C. The specimens then were subjected to a compressive load in a universal testing machine at a crosshead speed of 0.5 mm min-1. ANOVA and t-test were used for statistical analysis.Results: Mean fracture resistance of first and second molar teeth were 975.5 N (SD=368.8 and 1049.2 N (SD=540.1 respectively. In the first molar group, fracture resis-tance of two-surface cavities was significantly more than three-surface cavities (P<0.001, however this difference was not statistically significant in the second molar group. In both first and second molar group, fracture resistance incavities with 2.5 mm wall thickness, was significantly more than the group with 1.5 mm wall thickness.Conclusion: The mean fracture resistance in pulpotomized primary molar restored with amalgam restorations was higher than reported maximum bite force in primary teeth even in extensive multi-surface restorations. Therefore, the teeth with large proximal carious lesions in schoolchildren could be restored with amalgam.

  6. Polarization and molar volumes of ortho- and para-deuterium solutions

    International Nuclear Information System (INIS)

    Milenko, Yu.Ya.; Sibileva, R.M.

    1976-01-01

    The dielectric constant of liquid solutions of ortho-and para-deuterium is measured over the range of 2.2-91% p-D 2 from 18.7 to 20.4deg K. Data on polarization and molar volumes are obtained for the whole (0-100%) concentration range. Corrected summary to paper [2] is also listed: dielectric constant of ortho- and para-hydrogen liquid solution is measured within a concentration range of 0-97% of o-molecules at 14-20.4deg K. It is established that dependence of the Clausius-Mossotti function for o-p-hydrogen solutions of o-p-composition is linear. Molar volumes of the o-p-mixtures are calculated. The excessive molar volumes are found, positive deviation from additivity, 0.15% is established

  7. Origin of choriocarcinoma in previous molar pregnancy proved by DNA analysis

    International Nuclear Information System (INIS)

    Vojtassak, J.; Repiska, V.; Konecna, B.; Zajac, V.; Korbel, M.; Danihel, L.

    1996-01-01

    A 17-year old woman had in a short time period (seven months) a very exciting reproduction history. Molar pregnancy in December 1993, choriocarcinoma in January 1994 and induced abortion in June 1994. DNA analysis proved the origin of the choriocarcinoma in the previous molar pregnancy. (author)

  8. Assessment of age of majority by measurement of open apices of the third molars using Cameriere's third molar maturity index.

    Science.gov (United States)

    Sharma, Preeti; Wadhwan, Vijay; Ravi Prakash, S M; Aggarwal, Pooja; Sharma, Neeraj

    2017-01-01

    Evaluation of biological age of a living subject around the legal cutoff age for adulthood has become a grave concern for forensic experts in India, mainly due to the consequences of criminal obligations in judicial proceedings. Thus, this study was planned to examine the open apices of third molars in discriminating between individuals who are aged 18 years or older and who are not 18 years or older and to assign a cutoff for estimation of the age of 18 years. Orthopantomographs of 1062 individuals (14 and 23 years) were assessed, to verify Cameriere's third molar maturity index (I 3M ). The apical ends of the roots of the left mandibular third molar were analyzed. If the apical ends of the roots are completely closed, then I 3M is zero; otherwise, it is calculated as the sum of the distances between the inner sides of the two open apices divided by the tooth length. The sensitivity of the test for 0.08 value was 74.7% for males and 66% for females. Specificity was 83.6% for males and 79.6% for females. The probability that an Indian individual with an I 3M age in Indian population.

  9. Endodontic therapy for a fused mandibular molar.

    Science.gov (United States)

    Rotstein, I; Moshonov, J; Cohenca, N

    1997-06-01

    Variations in tooth morphology present a clinical challenge when endodontic treatment is required. A case of conservative endodontic therapy for a fused mandibular second and third molar is presented.

  10. Clinical and orthopantomographic evaluation of mandibular third molar

    Directory of Open Access Journals (Sweden)

    F K Saraswati

    2010-01-01

    Full Text Available Objective: To evaluate sensitivity of orthopentograph (OPG in assessing the number and morphology of roots of the mandibular third molar. Materials and Methods : The study population consisted of 100 ILTMs (impacted lower third molars ranging from 18 to 42 years with equal sex distribution. All the teeth were subsequently extracted , collected and compared with OPG features for position, numb,er, morphology, and relation to mandibular canal. Conclusion: In conclusion, a large sample study is suggested with techniques like Clark′s and right angle technique which determines the three-dimensional orientation of the impacted teeth.

  11. Molar-incisor-hypomineralisation (MIH). Retrospective clinical study in Greek children. I. Prevalence and defect characteristics.

    Science.gov (United States)

    Lygidakis, N A; Dimou, G; Briseniou, E

    2008-12-01

    This was to evaluate the prevalence and the clinical characteristics of MIH in a group of Greek children. During the years 2003--2005, all MIH cases diagnosed according to the recently set criteria were selected from the new patients clinic of a Community Dental Centre for Children (Athens). Age, gender and teeth involved were recorded. The severity of MIH was determined collectively by dividing the affected teeth in two groups; a) mild defect (demarcated opacities) and b) moderate/severe defect (enamel breakdown and atypical restorations). Evaluation of the distribution of the affected teeth within MIH cases was performed in a separate group of 225 affected children aged 8-12 years with their entire 12 'index' teeth erupted. From the 3,518, 5.5 to 12 year old children that were examined, there were 360 (10.2%) children with MIH, 211 (58.6%) females and 149 (41.4%) males, with 1,926 affected teeth, 1,231 molars and 695 incisors. In the molars group, maxillary molars were more frequently affected (87.8/90.3%) than mandibular (81.7/82.2%). In the central incisor group, maxillary teeth were also more frequently affected (50/55%) than mandibular (24.4/25%), while laterals were the least affected. In all there were 37.9% molars with moderate/severe defects as compared with 4.9% incisors, the remaining 62.1% and 95.1% respectively being mild. The various associations between the affected teeth were evaluated in the sub-group of 225 MIH children with all 'index' teeth erupted (1,286 affected teeth, 776 molars and 510 incisors), with mean number of affected teeth per child being 5.7; separately for molars 3.4 and for incisors 2.2. In these cases 28.4% of the children had only molars affected and 71.6% had both molars and incisors. In descending order the associations of affected teeth more frequently found were: 4 molars/2 incisors (23.5%), 4 molars/4 incisors (16.8%), 4 molars alone (15.1%) and 2 molars alone (9.7%), the remaining being much less. As age increased the

  12. Heat pipe effects in nuclear waste isolation: a review

    International Nuclear Information System (INIS)

    Doughty, C.; Pruess, K.

    1985-12-01

    The existence of fractures favors heat pipe development in a geologic repository as does a partially saturated medium. A number of geologic media are being considered as potential repository sites. Tuff is partially saturated and fractured, basalt and granite are saturated and fractured, salt is unfractured and saturated. Thus the most likely conditions for heat pipe formation occur in tuff while the least likely occur in salt. The relative permeability and capillary pressure dependences on saturation are of critical importance for predicting thermohydraulic behavior around a repository. Mineral redistribution in heat pipe systems near high-level waste packages emplaced in partially saturated formations may significantly affect fluid flow and heat transfer processes, and the chemical environment of the packages. We believe that a combined laboratory, field, and theoretical effort will be needed to identify the relevant physical and chemical processes, and the specific parameters applicable to a particular site. 25 refs., 1 fig

  13. Strains Around Abutment Teeth with Different Attachments Used for Implant-Assisted Distal Extension Partial Overdentures: An In Vitro Study.

    Science.gov (United States)

    ELsyad, Moustafa Abdou; Omran, Abdelbaset Omar; Fouad, Mohammed Mohammed

    2017-01-01

    The aim of this study was to evaluate and compare strain around abutment teeth with different attachments used for implant-assisted distal extension partial overdentures (IADEPODs). A mandibular Kennedy class I acrylic model (remaining teeth from first premolar to first premolar) was constructed. A conventional partial denture was constructed over the model (control, group 1). Two laboratory implants were then placed bilaterally in the first molar areas parallel to each other and perpendicular to the residual ridge. Three additional experimental partial overdentures (PODs) were constructed and connected to the implants using ball (group 2), magnetic (group 3), and Locator (group 4) attachments. Three linear strain gauges were bonded buccal, lingual, and distal to the first premolar abutment tooth at the right (loading) and the left (nonloading) sides. For each group, a universal testing device was used to apply a unilateral vertical static load (50 N) on the first molar area, and the strain was recorded using a multichannel digital strainometer. Significant differences between groups and between sites of strain gauges were detected. Strains recorded for all groups were compressive (negative) in nature. Group 1 demonstrated the highest strain, followed by group 3 and group 4; group 2 recorded the lowest strain. For group 2, the highest strain was recoded at the lingual nonloading side. For group 1, group 3, and group 4, the highest strain was recorded at the buccal loading side. Within the limitation of the present study, ball attachments used to retain IADEPODs to the implants were associated with lower strains around abutment teeth than Locator and magnetic attachments. The highest strain was recorded with conventional partial dentures. © 2015 by the American College of Prosthodontists.

  14. What is the fundamental ion-specific series for anions and cations? Ion specificity in standard partial molar volumes of electrolytes and electrostriction in water and non-aqueous solvents† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c7sc02691a Click here for additional data file.

    Science.gov (United States)

    Mazzini, Virginia

    2017-01-01

    The importance of electrolyte solutions cannot be overstated. Beyond the ionic strength of electrolyte solutions the specific nature of the ions present is vital in controlling a host of properties. Therefore ion specificity is fundamentally important in physical chemistry, engineering and biology. The observation that the strengths of the effect of ions often follows well established series suggests that a single predictive and quantitative description of specific-ion effects covering a wide range of systems is possible. Such a theory would revolutionise applications of physical chemistry from polymer precipitation to drug design. Current approaches to understanding specific-ion effects involve consideration of the ions themselves, the solvent and relevant interfaces and the interactions between them. Here we investigate the specific-ion effects trends of standard partial molar volumes and electrostrictive volumes of electrolytes in water and eleven non-aqueous solvents. We choose these measures as they relate to bulk properties at infinite dilution, therefore they are the simplest electrolyte systems. This is done to test the hypothesis that the ions alone exhibit a specific-ion effect series that is independent of the solvent and unrelated to surface properties. The specific-ion effects trends of standard partial molar volumes and normalised electrostrictive volumes examined in this work show a fundamental ion-specific series that is reproduced across the solvents, which is the Hofmeister series for anions and the reverse lyotropic series for cations, supporting the hypothesis. This outcome is important in demonstrating that ion specificity is observed at infinite dilution and demonstrates that the complexity observed in the manifestation of specific-ion effects in a very wide range of systems is due to perturbations of solvent, surfaces and concentration on the underlying fundamental series. This knowledge will guide a general understanding of specific

  15. Standard molar enthalpies of formation of three methyl-pyrazole derivatives

    International Nuclear Information System (INIS)

    Ribeiro da Silva, Manuel A.V.; Cabral, Joana I.T.A.

    2012-01-01

    Highlights: ► Combustion calorimetry was used to determine Δ f H m ∘ (cr) of methyl-pyrazole derivatives. ► Vapour pressures were determined by the Knudsen mass-loss effusion technique. ► Gas-phase Δ f H m ∘ of the studied compounds have been derived. - Abstract: The standard (p ° = 0.1 MPa) molar enthalpies of formation of the crystalline 3-methyl-1-pyrazolecarboxamide; 3-methyl-3-pyrazoline-5-one; and 4-methyl-2-pyrazoline-5-one were derived from the standard massic energies of combustion, in oxygen, to yield CO 2 (g), H 2 O (l) and N 2 (g), at T = 298.15 K, measured by static bomb combustion calorimetry. The standard molar enthalpies of sublimation were calculated from the variation of the vapour pressures of each compound with temperature, measured by the Knudsen effusion technique. These two thermodynamic parameters yielded the standard molar enthalpies of formation of the pyrazole derivatives, in the gaseous phase, at T = 298.15 K. The derived standard molar enthalpies of formation, in gaseous state, are analyzed in terms of enthalpic increments and interpreted in terms of molecular structure.

  16. Hypomineralized second primary molars: prevalence data in Dutch 5-year-olds

    NARCIS (Netherlands)

    Elfrink, M.E.C.; Schuller, A.A.; Weerheijm, K.L.; Veerkamp, J.S.J.

    2008-01-01

    The aim of this cross-sectional observational study was to report on the prevalence of hypomineralizations in second primary molars in 5-year-old Dutch children. In the study 386 (45% girls) 5-year-old Dutch children, all insured by a Health Insurance Fund, participated. Scoring criteria for molar

  17. Three-dimensional primate molar enamel thickness.

    Science.gov (United States)

    Olejniczak, Anthony J; Tafforeau, Paul; Feeney, Robin N M; Martin, Lawrence B

    2008-02-01

    Molar enamel thickness has played an important role in the taxonomic, phylogenetic, and dietary assessments of fossil primate teeth for nearly 90 years. Despite the frequency with which enamel thickness is discussed in paleoanthropological discourse, methods used to attain information about enamel thickness are destructive and record information from only a single plane of section. Such semidestructive planar methods limit sample sizes and ignore dimensional data that may be culled from the entire length of a tooth. In light of recently developed techniques to investigate enamel thickness in 3D and the frequent use of enamel thickness in dietary and phylogenetic interpretations of living and fossil primates, the study presented here aims to produce and make available to other researchers a database of 3D enamel thickness measurements of primate molars (n=182 molars). The 3D enamel thickness measurements reported here generally agree with 2D studies. Hominoids show a broad range of relative enamel thicknesses, and cercopithecoids have relatively thicker enamel than ceboids, which in turn have relatively thicker enamel than strepsirrhine primates, on average. Past studies performed using 2D sections appear to have accurately diagnosed the 3D relative enamel thickness condition in great apes and humans: Gorilla has the relatively thinnest enamel, Pan has relatively thinner enamel than Pongo, and Homo has the relatively thickest enamel. Although the data set presented here has some taxonomic gaps, it may serve as a useful reference for researchers investigating enamel thickness in fossil taxa and studies of primate gnathic biology.

  18. Stability test for a parabolic partial differential equation

    NARCIS (Netherlands)

    Vajta, Miklos

    2001-01-01

    The paper describes a stability test applied to coupled parabolic partial differential equations. The PDE's describe the temperature distribution of composite structures with linear inner heat sources. The distributed transfer functions are developed based on the transmission matrix of each layer.

  19. Excess Molar Volume, Viscosity and Heat Capacity for the Mixture of 1,2-Propanediol-Water at Different Temperatures%1,2-丙二醇水溶液在不同温度下的超额摩尔体积黏度和热容

    Institute of Scientific and Technical Information of China (English)

    杨长生; 马沛生; 唐多强; 靳凤民

    2003-01-01

    Experimental densities, viscosities and heat capacities at different temperatures were presented over the entire mole fraction range for the binary mixture of 1,2-propanediol and water. Density values were used in the determination of excess molar volumes, VE. At the same time, the excess viscosity was investigated. The values of VE and ηE were fitted to the Redlich-Kister equation. Good agreement was observed. The excess volumes are negative over the entire range of composition. They show an U-shaped-concentration dependence and decrease in absolute values with increase of temperature. Values of ηE are negative over the entire range of the composition, and has a trend very similar to that of VE . The analysis shows that at any temperature the specific heat of mixture is a linear function of the composition as x1>20%. All the extended lines intersect at one point. An empirical equation is obtained to calculate the specific heat to mixture at any composition and temperature in the experimental range.

  20. Pressure Dependence of Molar Volume near the Melting Point in Benzene

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The pressure dependence of the molar volume was at constant temperatures close to the melting point in benzene. The molar volume of benzene was calculated using experimental data for the thermal expansivity for constant temperatures of 25℃, 28.5℃, 40℃, and 51℃ at various pressures for both the solid and liquid phases. The predictions are in good agreement with the observed volumes in both the solid and liquid phases of benzene. The predicted values of the molar volume for a constant temperature of 28.5℃ in the liquid phase of benzene agree well with experimental data in the literature.