  1. The theory and measurement of partial discharge transients

    DEFF Research Database (Denmark)

    Pedersen, Aage; Crichton, George C; McAllister, Iain Wilson

    1991-01-01

    A theoretical approach to partial discharge transients is presented. This approach is based on the relationship between the charge induced on the measurement electrode by those created in the interelectrode volume during partial discharge activity. The primary sources for these induced charges ar...... electrode systems of practical interest is illustrated. A discussion of the salient features and practical aspects of the theory is included...

  2. Development of Partial Discharging Simulation Test Equipment

    Science.gov (United States)

    Kai, Xue; Genghua, Liu; Yan, Jia; Ziqi, Chai; Jian, Lu

    2017-12-01

    In the case of partial discharge training for recruits who lack of on-site work experience, the risk of physical shock and damage of the test equipment may be due to the limited skill level and improper operation by new recruits. Partial discharge simulation tester is the use of simulation technology to achieve partial discharge test process simulation, relatively true reproduction of the local discharge process and results, so that the operator in the classroom will be able to get familiar with and understand the use of the test process and equipment.The teacher sets up the instrument to display different partial discharge waveforms so that the trainees can analyze the test results of different partial discharge types.

  3. SVM-based Partial Discharge Pattern Classification for GIS

    Science.gov (United States)

    Ling, Yin; Bai, Demeng; Wang, Menglin; Gong, Xiaojin; Gu, Chao

    2018-01-01

    Partial discharges (PD) occur when there are localized dielectric breakdowns in small regions of gas insulated substations (GIS). It is of high importance to recognize the PD patterns, through which we can diagnose the defects caused by different sources so that predictive maintenance can be conducted to prevent from unplanned power outage. In this paper, we propose an approach to perform partial discharge pattern classification. It first recovers the PRPD matrices from the PRPD2D images; then statistical features are extracted from the recovered PRPD matrix and fed into SVM for classification. Experiments conducted on a dataset containing thousands of images demonstrates the high effectiveness of the method.

  4. Comments on evaluation of energy of partial discharges in ionization chambers

    International Nuclear Information System (INIS)

    Lechowski, Z.

    1980-01-01

    A method of evaluation of energy of partial discharges in ionization chambers which are intended for investigation on electric strength of insulating materials is presented. It is demonstrated that an ionization chamber must be considered as a set of discharge sources and that for energy evaluation an amplitude analysis of apparent charge of discharges is useful. (author)

  5. Use of ultrasonic array method for positioning multiple partial discharge sources in transformer oil.

    Science.gov (United States)

    Xie, Qing; Tao, Junhan; Wang, Yongqiang; Geng, Jianghai; Cheng, Shuyi; Lü, Fangcheng

    2014-08-01

    Fast and accurate positioning of partial discharge (PD) sources in transformer oil is very important for the safe, stable operation of power systems because it allows timely elimination of insulation faults. There is usually more than one PD source once an insulation fault occurs in the transformer oil. This study, which has both theoretical and practical significance, proposes a method of identifying multiple PD sources in the transformer oil. The method combines the two-sided correlation transformation algorithm in the broadband signal focusing and the modified Gerschgorin disk estimator. The method of classification of multiple signals is used to determine the directions of arrival of signals from multiple PD sources. The ultrasonic array positioning method is based on the multi-platform direction finding and the global optimization searching. Both the 4 × 4 square planar ultrasonic sensor array and the ultrasonic array detection platform are built to test the method of identifying and positioning multiple PD sources. The obtained results verify the validity and the engineering practicability of this method.

  6. Ultrasonic partial discharge monitoring method on instrument transformers

    Directory of Open Access Journals (Sweden)

    Kartalović Nenad

    2012-01-01

    Full Text Available Sonic and ultrasonic partial discharge monitoring have been applied since the early days of these phenomena monitoring. Modern measurement and partial discharge acoustic (ultrasonic and sonic monitoring method has been rapidly evolving as a result of new electronic component design, information technology and updated software solutions as well as the development of knowledge in the partial discharge diagnosis. Electrical discharges in the insulation system generate voltage-current pulses in the network and ultrasonic waves that propagate through the insulation system and structure. Amplitude-phase-frequency analysis of these signals reveals information about the intensity, type and location of partial discharges. The paper discusses the possibility of ultrasonic method selectivity improvement and the increase of diagnosis reliability in the field. Measurements were performed in the laboratory and in the field while a number of transformers were analysed for dissolved gases in the oil. A comparative review of methods for the partial discharge detection is also presented in this paper.

  7. Inductive Sensor Performance in Partial Discharges and Noise Separation by Means of Spectral Power Ratios

    Directory of Open Access Journals (Sweden)

    Jorge Alfredo Ardila-Rey

    2014-02-01

    Full Text Available Partial discharge (PD detection is a standardized technique to qualify electrical insulation in machines and power cables. Several techniques that analyze the waveform of the pulses have been proposed to discriminate noise from PD activity. Among them, spectral power ratio representation shows great flexibility in the separation of the sources of PD. Mapping spectral power ratios in two-dimensional plots leads to clusters of points which group pulses with similar characteristics. The position in the map depends on the nature of the partial discharge, the setup and the frequency response of the sensors. If these clusters are clearly separated, the subsequent task of identifying the source of the discharge is straightforward so the distance between clusters can be a figure of merit to suggest the best option for PD recognition. In this paper, two inductive sensors with different frequency responses to pulsed signals, a high frequency current transformer and an inductive loop sensor, are analyzed to test their performance in detecting and separating the sources of partial discharges.

  8. Partial discharges and bulk dielectric field enhancement

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Johansson, Torben

    2000-01-01

    A consequence of partial discharge activity within a gaseous void is the production of a field enhancement in the solid dielectric in the proximity of the void. This situation arises due to the charge created by the partial discharges accumulating at the void wall. The influence of the spatial...

  9. A novel technique for partial discharge measurement

    International Nuclear Information System (INIS)

    Farrokh, Fattahi; Navid, Tagizadegan; Ahmad, Zentabchi; Mehdi, Rashidi

    2005-01-01

    Full text : Partial discharges are a sensitive measure of local electrical stress and therefore the measurements is very often used as a quality check of the insulation. The inception of partial discharges gives information on the limit of the electrical strength of the insulating material before a complete discharge between the conductors takes place. Therefore the insulating material can be tested with high stress but without damaging or reducing the performance of the insulation. Also, for partial discharge measurements it should be taken into account that every stress of the insulation will have an influence on the life expectancy of the material, but a reasonable compromise between the stress during the measurement in order to get reliable results and the influence of he lifetime should be found and established in the relevant standard for the particular equipment, for example transformers, cables and so on

  10. Partial discharge transients: The field theoretical approach

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Crichton, George C

    1998-01-01

    Up until the mid-1980s the theory of partial discharge transients was essentially static. This situation had arisen because of the fixation with the concept of void capacitance and the use of circuit theory to address what is in essence a field problem. Pedersen rejected this approach and instead...... began to apply field theory to the problem of partial discharge transients. In the present paper, the contributions of Pedersen using the field theoretical approach will be reviewed and discussed....

  11. Computer-based instrumentation for partial discharge detection in GIS

    International Nuclear Information System (INIS)

    Md Enamul Haque; Ahmad Darus; Yaacob, M.M.; Halil Hussain; Feroz Ahmed

    2000-01-01

    Partial discharge is one of the prominent indicators of defects and insulation degradation in a Gas Insulated Switchgear (GIS). Partial discharges (PD) have a harmful effect on the life of insulation of high voltage equipment. The PD detection using acoustic technique and subsequent analysis is currently an efficient method of performing non-destructive testing of GIS apparatus. A low cost PC-based acoustic PD detection instrument has been developed for the non-destructive diagnosis of GIS. This paper describes the development of a PC-based instrumentation system for partial discharge detection in GIS and some experimental results have also presented. (Author)

  12. Partial discharge transients and the influence of dielectric polarization

    DEFF Research Database (Denmark)

    Pedersen, A.; Crichton, George C; McAllister, Iain Wilson

    1996-01-01

    Based on a field-theoretical approach, a physically valid theory of partial discharge transients has been developed. The theory is based upon the concept of the charge induced upon the detecting electrode by the partial discharge. This induced charge is shown to be composed of a component...

  13. Partial discharges in ellipsoidal and spheroidal voids

    DEFF Research Database (Denmark)

    Crichton, George C; Karlsson, P. W.; Pedersen, Aage

    1989-01-01

    Transients associated with partial discharges in voids can be described in terms of the charges induced on the terminal electrodes of the system. The relationship between the induced charge and the properties which are usually measured is discussed. The method is illustrated by applying it to a s......Transients associated with partial discharges in voids can be described in terms of the charges induced on the terminal electrodes of the system. The relationship between the induced charge and the properties which are usually measured is discussed. The method is illustrated by applying...

  14. Partial discharge patterns related to surface deterioration in voids in epoxy

    DEFF Research Database (Denmark)

    Holbøll, Joachim; Henriksen, Mogens

    1990-01-01

    Results are presented from an investigation of the relationship between changes in partial discharge patterns and the surface deterioration process taking place in small naturally formed spherical voids in epoxy plastic. The voids were exposed to a moderate electric stress above inception level......, where partial discharges were present for more than 1500 h. Two types of electrical tree growth were found, the bush like tree and a single channel-like tree, which led to very different partial discharge patterns. It is concluded that the formation of crystals on a void surface leads to an immediate...... and easy-to-detect increase in the partial discharge activity with subsequent severe surface deterioration (deep pit formations) in the vicinity of the crystal. However, the partial discharge signal from a specimen with a black channel-like tree structure did not give any indication of channel growth...

  15. Solving of some Problems with On-Line Mode Measurement of Partial Discharges

    Directory of Open Access Journals (Sweden)

    Karel Zalis

    2004-01-01

    Full Text Available This paper deals with the problems discussing the transition from off-line diagnostic methods to on-line ones. Based on the experience with commercial partial discharge measuring equipment a new digital system for the evaluation of partial discharge measurement including software and hardware facilities has been developed at the Czech Technical University in Prague. Two expert systems work in this complex evaluating system: a rule-based expert system performing an amplitude analysis of partial discharge impulses for determining the damage of the insulation system, and a neural network which is used for a phase analysis of partial discharge impulses to determine the kind of partial discharge activity. Problem of the elimination of disturbances is also discussed.

  16. Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors.

    Science.gov (United States)

    Castro, Bruno; Clerice, Guilherme; Ramos, Caio; Andreoli, André; Baptista, Fabricio; Campos, Fernando; Ulson, José

    2016-08-10

    Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique.

  17. Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors

    Directory of Open Access Journals (Sweden)

    Bruno Castro

    2016-08-01

    Full Text Available Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique.

  18. Partial discharge testing of in-situ power cable accessories

    Energy Technology Data Exchange (ETDEWEB)

    Orban, H. E.

    2002-07-01

    An overview of commercially available diagnostic methods for in-situ power cable accessories is given and relevant field experiences with these diagnostics are described. The discussion includes both PILC and polymeric insulated cables. Two major types of degradation are most frequently involved in cable systems. One is an overall condition caused by chemical aging and /or water treeing. Diagnostics for this type of aging include dissipation factor (loss angle), harmonic analysis, return voltage, isothermal relaxation current, dielectric response, or dc leakage current. The second type of degradation is discrete or incremental; condition assessment utilizes dissipation factor measurements or partial discharge (PD) level measurements. The focus in this paper is on PD diagnostics, especially off-line methods such as the 60 Hz test, the combined AC and VLF diagnostic, and the oscillating wave test system test. Among on-line diagnostics, ultrasonic detection of partial discharge and measurement of partial discharge by installing direct, capacitive or inductive couplers near cable accessories, are described. Overall, partial discharge detection and location in cable accessories is considered inadequate, since interpretation of results is difficult due to the number of variables involved. 28 refs., 1 tab.

  19. On the electrodynamics of partial discharges in voids in solid dielectrics

    DEFF Research Database (Denmark)

    Pedersen, Aage

    1989-01-01

    It is suggested that a correct interpretation of partial-discharge transients can be obtained only through the concept of induced charge. The application of this concept enables a partial-discharge theory to be developed by means of which the influence of relevant void parameters can be assessed ...

  20. Study and optimization of the partial discharges in capacitor model ...

    African Journals Online (AJOL)

    that the main cause of failure of these devices is the appearance of partial discharges initiated on edges of armatures. These devices can quickly slam if discharges occur continuously during the liquid impregnation. One of the criteria for selecting impregnating liquids is the behavior of gas bubbles when discharges occur.

  1. An all-fiber partial discharge monitoring system based on both intrinsic fiber optic interferometry sensor and fluorescent fiber

    Science.gov (United States)

    Yin, Zelin; Zhang, Ruirui; Tong, Jie; Chen, Xi

    2013-12-01

    Partial discharges (PDs) are an electrical phenomenon that occurs within a transformer whenever the voltage stress is sufficient to produce ionization in voids or inclusions within a solid dielectric, at conductor/dielectric interfaces, or in bubbles within liquid dielectrics such as oil; high-frequency transient current discharges will then appear repeatedly and will progressively deteriorate the insulation, ultimately leading to breakdown. Fiber sensor has great potential on the partial discharge detection in high-voltage equipment for its immunity to electromagnetic interference and it can take direct measurement in the high voltage equipment. The energy released in PDs produces a number of effects, resulting in flash, chemical and structural changes and electromagnetic emissions and so on. Acoustic PD detection is based on the mechanical pressure wave emitted from the discharge and fluorescent fiber PD detection is based on the emitted light produced by ionization, excitation and recombination processes during the discharge. Both of the two methods have the shortage of weak anti-interference capacity in the physical environment, like thunder or other sound source. In order to avoid the false report, an all-fiber combined PD detection system of the two methods is developed in this paper. In the system the fluorescent fiber PD sensor is considered as a reference signal, three F-P based PD detection sensors are used to both monitor the PD intensity and calculate the exact position of the discharge source. Considering the wave band of the F-P cavity and the fluorescent probe are quite different, the reflection spectrum of the F-P cavity is in the infrared region, however the fluorescent probe is about 600nm to 700nm, thus the F-P sensor and fluorescent fiber probe can be connected in one fiber and the reflection light can be detected by two different detectors without mutual interference. The all-fiber partial discharge monitoring system not only can detect the PDs

  2. A Comparison of Inductive Sensors in the Characterization of Partial Discharges and Electrical Noise Using the Chromatic Technique.

    Science.gov (United States)

    Ardila-Rey, Jorge Alfredo; Montaña, Johny; de Castro, Bruno Albuquerque; Schurch, Roger; Covolan Ulson, José Alfredo; Muhammad-Sukki, Firdaus; Bani, Nurul Aini

    2018-03-29

    Partial discharges (PDs) are one of the most important classes of ageing processes that occur within electrical insulation. PD detection is a standardized technique to qualify the state of the insulation in electric assets such as machines and power cables. Generally, the classical phase-resolved partial discharge (PRPD) patterns are used to perform the identification of the type of PD source when they are related to a specific degradation process and when the electrical noise level is low compared to the magnitudes of the PD signals. However, in practical applications such as measurements carried out in the field or in industrial environments, several PD sources and large noise signals are usually present simultaneously. In this study, three different inductive sensors have been used to evaluate and compare their performance in the detection and separation of multiple PD sources by applying the chromatic technique to each of the measured signals.

  3. Partial discharges in spheroidal voids: Void orientation

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson

    1997-01-01

    Partial discharge transients can be described in terms of the charge induced on the detecting electrode. The influence of the void parameters upon the induced charge is examined and discussed for spheroidal voids. It is shown that a quantitative interpretation of the induced charge requires...

  4. The electric strength of high-voltage transformers insulation at effect of partial dischargers

    International Nuclear Information System (INIS)

    Khoshravan, E.; Zeraatparvar, A.; Gashimov, A.M.; Mehdizadeh, R.N.

    2001-01-01

    Full text : In paper the change of electric strength of high-voltage transformers insulation at the effect of partial discharges with space charge accumulation was investigated. It is revealed that the effect of partial discharges of insulation materials results the reduction of their pulsing electric strength which can restore the own initial value at releasing of saved charge the volume of a material under condition of absence the ineversible structural changes in it. Researches of high-voltage transformers insulation's non-failure operation conditions show, that at increasing of insulation work time in a strong electrical field the reduction of average breakdown voltages with simultaneous increasing of spread in discharge voltage values takes place. It authentically testifies to reduction of short-time discharge voltage of insulation materials during their electrical aging. As the basic reason of insulation electrical aging the partial discharges occurring in gas cavities inside insulation were considered. It is known that the space charges will be formed in insulation elements of high-voltage devices which effects in dielectrical property of these elements including the electric strength and the space charge formation can occur also at partial discharges in an alternating voltage while the service of high-voltage transformers. In the given work the experiments in revealing separate influence partial discharges in pulsing electric strength of insulation materials at presence and at absence inside them the space charge were spent

  5. Method for measuring the stochastic properties of corona and partial-discharge pulses

    International Nuclear Information System (INIS)

    Van Brunt, R.J.; Kulkarni, S.V.

    1989-01-01

    A new method is described for measuring the stochastic behavior of corona and partial-discharge pulses which utilizes a pulse selection and sorting circuit in conjunction with a computer-controlled multichannel analyzer to directly measure various conditional and unconditional pulse-height and pulse-time-separation distributions. From these measured distributions it is possible to determine the degree of correlation between successive discharge pulses. Examples are given of results obtained from measurements on negative, point-to-plane (Trichel-type) corona pulses in a N 2 /O 2 gas mixture which clearly demonstrate that the phenomenon is inherently stochastic in the sense that development of a discharge pulse is significantly affected by the amplitude of and time separation from the preceding pulse. It is found, for example, that corona discharge pulse amplitude and time separation from an earlier pulse are not independent random variables. Discussions are given about the limitations of the method, sources of error, and data analysis procedures required to determine self-consistency of the various measured distributions

  6. A Comparison of Inductive Sensors in the Characterization of Partial Discharges and Electrical Noise Using the Chromatic Technique

    Directory of Open Access Journals (Sweden)

    Jorge Alfredo Ardila-Rey

    2018-03-01

    Full Text Available Partial discharges (PDs are one of the most important classes of ageing processes that occur within electrical insulation. PD detection is a standardized technique to qualify the state of the insulation in electric assets such as machines and power cables. Generally, the classical phase-resolved partial discharge (PRPD patterns are used to perform the identification of the type of PD source when they are related to a specific degradation process and when the electrical noise level is low compared to the magnitudes of the PD signals. However, in practical applications such as measurements carried out in the field or in industrial environments, several PD sources and large noise signals are usually present simultaneously. In this study, three different inductive sensors have been used to evaluate and compare their performance in the detection and separation of multiple PD sources by applying the chromatic technique to each of the measured signals.

  7. Design parameter based method of partial discharge detection and location in power transformers

    Directory of Open Access Journals (Sweden)

    Kumar Santosh Annadurai

    2009-01-01

    Full Text Available Insulation defect detection in time ensures higher operational reliability of power system assets. Power transformers are the most critical unit of power systems both from economical and operational front. Hence it becomes necessary to have knowledge of the actual insulation condition of transformer to increase dependability of the system. The performance and ageing of the transformer insulation is mainly affected by Partial discharges (PD. Proper diagnosis in terms of amplitude and location of partial discharge in a power transformer enables us to predict well in advance, with much confidence, the defect in insulation system, which avoids large catastrophic failures. In this work a 20kVA, 230/50kV single phase core type transformer is used for evaluation of the transfer function-based partial discharge detection and location using modeling of the winding, using design data. The simulation of capturing on-line PD pulses across the bushing tap capacitor is done for various tap positions. Standard PD source model is used to inject PD pulse signal at 10 tap locations in the winding and corresponding response signatures are captured at the bushing tap end (across 1000pF. The equivalent high frequency model of the winding is derived from the design parameters using analytical calculations and simulations in packages such as MAGNET and ANSOFT. The test conditions are simulated using ORCAD-9 and the results are evaluated for location accuracy using design parameter based PD monitoring method. .

  8. Partial Discharge Phase Distribution Of Palm Oil As Insulating Liquid

    Directory of Open Access Journals (Sweden)

    Abdul Rajab

    2011-04-01

    Full Text Available Due to the low biodegradability level of mineral oil and its susceptibility to the fire, palm oil was proposed as alternative insulating liquid. This paper discusses partial discharge (PD in palm oil under sinusoidal voltages and the comparison with mineral oil. PD was generated using a needle-plane electrode configuration which is enable enhancing electric field at the needle tip. PD pulses were detected using RC detector and they were measured using a Computer-based partial discharge measurement system. The results showed that PD activities in both oils are similar. The PD was initiated at the negative polarity of applied voltage. The discharges took place in both polarity’s of applied voltage with PD number was higher at negative one. Several discharges phenomena showed the presence of space charge which changed electric field and governed PD activities besides the main field introduced by voltage application.

  9. On-line Monitoring Device for High-voltage Switch Cabinet Partial Discharge Based on Pulse Current Method

    Science.gov (United States)

    Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.

    2017-12-01

    The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.

  10. Evaluation of deterioration of insulators in high-voltage motors by partial discharge

    International Nuclear Information System (INIS)

    Mikami, Masao

    2003-01-01

    For the purpose of early detection of deterioration of insulators in high-voltage motors which are widely utilized in nuclear power stations, a new type on-line partial discharge monitor developed at INSS was applied to test the deterioration of about 150 sets of high-voltage motors running in nuclear power stations practically. From the results, it is shown that (1) tendency of the deterioration can be obtained by this method in general, (2) the magnitude of the on-line partial discharge hardly correlates with that of off-line measurement, but depends on temperature and other environmental conditions, and (3) by observing phase characteristics of partial discharge, it is possible to make a diagnosis of phase-to-phase tracking in end-winding coils of a stator. (author)

  11. A Novel Partial Discharge Ultra-High Frequency Signal De-Noising Method Based on a Single-Channel Blind Source Separation Algorithm

    Directory of Open Access Journals (Sweden)

    Liangliang Wei

    2018-02-01

    Full Text Available To effectively de-noise the Gaussian white noise and periodic narrow-band interference in the background noise of partial discharge ultra-high frequency (PD UHF signals in field tests, a novel de-noising method, based on a single-channel blind source separation algorithm, is proposed. Compared with traditional methods, the proposed method can effectively de-noise the noise interference, and the distortion of the de-noising PD signal is smaller. Firstly, the PD UHF signal is time-frequency analyzed by S-transform to obtain the number of source signals. Then, the single-channel detected PD signal is converted into multi-channel signals by singular value decomposition (SVD, and background noise is separated from multi-channel PD UHF signals by the joint approximate diagonalization of eigen-matrix method. At last, the source PD signal is estimated and recovered by the l1-norm minimization method. The proposed de-noising method was applied on the simulation test and field test detected signals, and the de-noising performance of the different methods was compared. The simulation and field test results demonstrate the effectiveness and correctness of the proposed method.

  12. Fiber Fabry-Perot sensors for detection of partial discharges in power transformers.

    Science.gov (United States)

    Yu, Bing; Kim, Dae Woong; Deng, Jiangdong; Xiao, Hai; Wang, Anbo

    2003-06-01

    A diaphragm-based interferometric fiberoptic sensor that uses a low-coherence light source was designed and tested for on-line detection of the acoustic waves generated by partial discharges inside high-voltage power transformers. The sensor uses a fused-silica diaphragm and a single-mode optical fiber encapsulated in a fused-silica glass tube to form an extrinsic Fabry-Perot interferometer, which is interrogated by low-coherence light. Test results indicate that these fiber optic acoustic sensors are capable of faithfully detecting acoustic signals propagating inside transformer oil with high sensitivity and wide bandwidth.

  13. Acoustic position finding of partial discharges in transformers. Combination of partial discharge measurement technology with 3D visualization; Akustische Ortung von Teilentladungen in Transformatoren. TE-Messtechnik und 3-D-Visualisierung kombiniert

    Energy Technology Data Exchange (ETDEWEB)

    Kraetge, Alexander; Hoek, Stefan [Omicron Electronics GmbH, Klaus (Austria)

    2013-11-01

    A new measuring system facilitates the detection of partial discharges in transformers by means of the fully synchronous combination of measurement technology for electrical partial discharges with intuitive 3D visualization of the test object. The contribution under consideration describes the application of this system with examples from the measurement practice.

  14. Ion source of discharge type

    Energy Technology Data Exchange (ETDEWEB)

    Enchevich, I.B. [TRIUMF, Cyclotron Div., Vancouver, British Columbia (Canada); Korenev, S.A. [JINR, Hihg Energy Physics Lab., Dubna, Moscow (Russian Federation)

    1992-07-01

    A new scheme of ion source based on a dielectric surface sliding discharge is described. The conditions to form this type of discharge are analyzed and experimental results are shown. The main parameters of this ion source are: accelerating voltage U = 1/20kV; continuous extracted ion beam; current density j = 0.01/0.5 A/cm{sup 2}; ions of Cl, F, C, H; residual gas pressure P = 10{sup -6} Torr. A magnetic system is used to separate the different types of ions. The dielectric material in the discharge circuit (anode plasma emitter) defines the type of ions. The emission characteristics of plasma emitter and the discharge parameters are presented. The ion current yield satisfies the Child-Langmuir law. (author)

  15. Ion source of discharge type

    International Nuclear Information System (INIS)

    Enchevich, I.B.; Korenev, S.A.

    1992-07-01

    A new scheme of ion source based on a dielectric surface sliding discharge is described. The conditions to form this type of discharge are analyzed and experimental results are shown. The main parameters of this ion source are: accelerating voltage U = 1/20kV; continuous extracted ion beam; current density j = 0.01/0.5 A/cm 2 ; ions of Cl, F, C, H; residual gas pressure P = 10 -6 Torr. A magnetic system is used to separate the different types of ions. The dielectric material in the discharge circuit (anode plasma emitter) defines the type of ions. The emission characteristics of plasma emitter and the discharge parameters are presented. The ion current yield satisfies the Child-Langmuir law. (author)

  16. Application to the system of insulated of diagnosis in high-voltage motors by partial discharge

    International Nuclear Information System (INIS)

    Mikami, M.

    2005-01-01

    In order to detect electric insulators degradation of high-voltage electric motors at an early stage, measurements of partial discharge of operating high-voltage electric motors (about 150 units) in the nuclear power plants were conducted from 2001 to 2004 by the use of on-line monitoring systems that could measure partial discharge of electric insulators. Influencing factors for measured values were identified from measured data and evaluation criteria of electric insulators integrity were established based on variations of partial discharge values. (T. Tanaka)

  17. Partial discharge tests and characterisation of the Advanced Photon Source linac modulator cables

    International Nuclear Information System (INIS)

    Cours, A.

    2007-01-01

    The advanced photon source (APS) linac modulators are PFN-type pulsers with switch-mode charging power supplies (PSs). The PS and the PFN are connected to each other by 15 feet of 100-kV x-ray cable, with the PFN end of the cable terminated with a connector that was confirmed partial-discharge (PD)-free up to 38 kV ac (53.5 kV peak). Another end of the cable is terminated with a connector that was designed by the PS manufacturer and cannot easily be replaced with another type of connector, since part of it is located inside the densely packed PS. PD tests of the cables with this type of connector show that the PD inception voltages (PDIVs) in different cables turn out to be located within a wide voltage range: 21 to 27 kV ac that corresponds to 29 to 38 kV peak. In order to evaluate the insulation condition of the modulator cables, detect insulation deterioration, and ensure failure-preventing equipment maintenance, over the last two years the PDIVs of all high-voltage (HV) cables in use in the modulators have been tested about every three and a half months. Before the tests, all cables were removed from the equipment, carefully cleaned, inspected, and regreased. The tests were performed using a 40-kV PD detector. The test results show that: 1 The PDIVs remain almost unchanged in all tested cables. 2 From test to test, the PDIV of any particular cable may slightly oscillate around some average value. This possibly depends on the connector regreasing technique. 3 There is no direct evidence of cable insulation deterioration during more than two years of operation under voltage higher than the PD inception level.

  18. Analysis of Insulating Material of XLPE Cables considering Innovative Patterns of Partial Discharges

    Directory of Open Access Journals (Sweden)

    Fernando Figueroa Godoy

    2017-01-01

    Full Text Available This paper aims to analyze the quality of insulation in high voltage underground cables XLPE using a prototype which classifies the following usual types of patterns of partial discharge (PD: (1 internal PD, (2 superficial PD, (3 corona discharge in air, and (4 corona discharge in oil, in addition to considering two new PD patterns: (1 false contact and (2 floating ground. The tests and measurements to obtain the patterns and study cases of partial discharges were performed at the Testing Laboratory Equipment and Materials (LEPEM of the Federal Electricity Commission of Mexico (CFE using a measuring equipment LDIC and norm IEC60270. To classify the six patterns of partial discharges mentioned above a Probabilistic Neural Network Bayesian Modified (PNNBM method having the feature of using a large amount of data will be used and it is not saturated. In addition, PNN converges, always finding a solution in a short period of time with low computational cost. The insulation of two high voltage cables with different characteristics was analyzed. The test results allow us to conclude which wire has better insulation.

  19. Statistical Analysis of Partial Discharge Characteristics in Transformer Oil at the “Point-Plane” Electrode at Alternating Voltage

    Directory of Open Access Journals (Sweden)

    Korobeynikov S.M.

    2017-08-01

    Full Text Available In this paper, we consider the problems related to measuring and analyzing the characteristics of partial discharges which are the main instrument for oil-filled high-voltage electrical equipment diagnosing. The experiments on recording of partial discharges in transformer oil have been carried out in the “point-plane” electrode system at alternating current. The instantaneous voltage and the apparent charge have been measured depending on the root-mean-square voltage and the phase angle of partial discharges. This paper aimes at carrying out a statistical analysis of the obtained experimental results, in particular, the construction of a parametric probabilistic model of the dependence of the partial discharge inception voltage distribution on the value of the root-mean-square voltage. It differs from usual discharges which occur in liquid dielectric materials in case of sharp inhomogeneous electrode system. It has been suggested that discharges of a different type are the discharges in gas bubbles that occur when partial discharges in a liquid emerge. This assumption is confirmed by the fact that the number of such discharges increases with increasing the root-mean-square voltage value. It is the main novelty of this paper. This corresponds to the nature of the occurrence of such discharges. After rejecting the observations corresponding to discharges in gas bubbles, a parametric probabilistic model has been constructed. The model obtained makes it possible to determine the probability of partial discharge occurrence in a liquid at a given value of the instantaneous voltage depending on the root-mean-square voltage.

  20. Critical analysis of partial discharge dynamics in air filled spherical voids

    Science.gov (United States)

    Callender, G.; Golosnoy, I. O.; Rapisarda, P.; Lewin, P. L.

    2018-03-01

    In this paper partial discharge (PD) is investigated inside a spherical air filled void at atmospheric pressure using a drift diffusion model. Discharge dynamics consisted of an electron avalanche transitioning into positive streamer, in agreement with earlier work on dielectric barrier discharges. Different model configurations were utilised to test many of the concepts employed in semi-analytical PD activity models, which use simplistic descriptions of the discharge dynamics. The results showed that many of these concepts may be erroneous, with significant discrepancies between the canonical reasoning and the simulation results. For example, the residual electric field, the electric field after a discharge, is significantly lower than the estimates used by classical PD activity models in the literature.

  1. A Review of Online Partial Discharge Measurement of Large Generators

    Directory of Open Access Journals (Sweden)

    Yuanlin Luo

    2017-10-01

    Full Text Available Online partial discharge (PD measurements have long been used as an effective means to assess the condition of the stator windings of large generators. An increase in the use of PD online measurement systems during the last decade is evident. Improvements in the detection capabilities are partly the reason for the increased popularity. Another reason has been the development of digital signal processing techniques. In addition, rapid progress is being made in automated single PD source classification. However, there are still some factors hindering wider application of the system, such as the complex PD mechanism and PD pulse propagation in stator windings, the presence of detrimental noise and disturbances on-site, and multiple PD sources occurring simultaneously. To avoid repetition of past work and to provide an overview for fresh researchers in this area, this paper presents a comprehensive survey of the state-of-the-art knowledge on PD mechanism, PD pulse propagation in stator windings, PD signal detection methods and signal processing techniques. Areas for further research are also presented.

  2. Study and optimization of the partial discharges in capacitor model ...

    African Journals Online (AJOL)

    The initial potential as well as the temperature are known to influence the partial discharge ... The development of electrostatic industry has ... the liquid impregnation. One of the ..... the Surface of Corona charged Uniforms layers of HIPS.

  3. On-line Monitoring System Based on Principle of Electro-acoustic Monitoring for Transformer Partial Discharge

    Directory of Open Access Journals (Sweden)

    Guang Ya LIU

    2014-02-01

    Full Text Available Partial discharge inside a transformer is mainly responsible for the insulation aging and damage of the transformer. However, partial discharge is usually accompanied by external signals like sound, light and electrical signals and detectable physical phenomena such as characteristical gas and dielectric loss. Therefore, it is of great significance to monitor online the external signals and phenomena formed during partial discharge of the transformer when the transformer diagnoses faults. This paper gives a comprehensive overview of the electro-acoustic joint monitoring principles and its monitoring systems and the judgment skills concerned, on the basis of which the monitoring system is designed.

  4. Development of a method of partial discharge detection in extra-high voltage cross-linked polyethylene insulated cable lines

    International Nuclear Information System (INIS)

    Katsuta, G.; Toya, A.; Muraoka, K.; Endoh, T.; Sekii, Y.; Ikeda, C.

    1992-01-01

    This paper reports that deterioration in the insulation performance of extra-high voltage XLPE cables is believed to be attributable to the deterioration caused by partial discharges. In the authors study, after using an XLPE cable to investigate the behavior of partial discharges under various adverse conditions, we succeeded in developing a highly sensitive new method of measuring partial discharge in XLPE cable lines. Partial discharges in a 275 kV XLPE cable live line has been measured using this newly developed method. As a result, a detection sensitivity of 1 pC has been achieved

  5. Partial discharge characteristics and mechanism in voids at impulse voltages

    International Nuclear Information System (INIS)

    Zhao, X F; Guo, Z F; Wang, Y Y; Li, J H; Li, Y M; Yao, X

    2011-01-01

    Partial discharge (PD) characteristics and mechanism in artificial cavities in an epoxy plate have been investigated for different void dimensions and impulse voltage waveforms. A differential measurement system was developed in order to detect PD current pulses effectively. Experimental results showed that the 50% probability PD inception voltage (PDIV 50 ) increases initially as the cavity diameter decreases at constant depth for double exponential impulses as well as oscillating impulses, but after aging, it becomes independent of the cavity diameter. Moreover, some distinctive characteristics of PD (e.g. main discharge and reverse discharge during the rise and fall phases of the applied voltage) were also investigated. The differences of the PD propagation and the mechanism between double exponential impulses and oscillating impulse were discussed

  6. Partial Discharge Tests using the Cigré II method

    DEFF Research Database (Denmark)

    Casale, M. Di Lorenzo del; Schifani, R.; Holbøll, Joachim

    2000-01-01

    In this paper, the results of an experimental project on insulating material aging, performed in both Denmark and Italy, are reported. This study was concerned with partial discharge (PD) behavior at temperatures between 30 and 80°C using CIGRE method II. The material tested was a commercial...... polymethylmethacrylate (PMMA) which was chosen not for its good dielectric properties but rather because much of its discharge resistance data at ambient temperature is already well documented. A description is given of the theoretical and experimental methodology followed in this work. Mixed Weibull analysis techniques...... in terms of the PD amplitude and phase distribution characteristics were employed to distinguish the presence of different aging mechanisms. Such a difference was observed at 30 and at 80°C. At 30°C the analysis inferred a single discharge aging process acting until breakdown, while at 80°C the results...

  7. A Rectangular Planar Spiral Antenna for GIS Partial Discharge Detection

    Directory of Open Access Journals (Sweden)

    Xiaoxing Zhang

    2014-01-01

    Full Text Available A rectangular planar spiral antenna sensor was designed for detecting the partial discharge in gas insulation substations (GIS. It can expediently receive electromagnetic waves leaked from basin-type insulators and can effectively suppress low frequency electromagnetic interference from the surrounding environment. Certain effective techniques such as rectangular spiral structure, bow-tie loading, and back cavity structure optimization during the antenna design process can miniaturize antenna size and optimize voltage standing wave ratio (VSWR characteristics. Model calculation and experimental data measured in the laboratory show that the antenna possesses a good radiating performance and a multiband property when working in the ultrahigh frequency (UHF band. A comparative study between characteristics of the designed antenna and the existing quasi-TEM horn antenna was made. Based on the GIS defect simulation equipment in the laboratory, partial discharge signals were detected by the designed antenna, the available quasi-TEM horn antenna, and the microstrip patch antenna, and the measurement results were compared.

  8. Study and optimization of the partial discharges in capacitor model ...

    African Journals Online (AJOL)

    Page 1 ... experiments methodology for the study of such processes, in view of their modeling and optimization. The obtained result is a mathematical model capable to identify the parameters and the interactions between .... 5mn; the next landing is situated in 200 V over the voltage of partial discharges appearance and.

  9. Propagation of Partial Discharge and Noise Pulses in Turbine Generators

    DEFF Research Database (Denmark)

    Henriksen, Mogens; Stone, G. C.; Kurtz, M.

    1986-01-01

    Changes with time in the partial discharge (PD) activity originating in a generator stator's insulation system provide information about the electrical integrity of the stator winding. It is desirable to measure PD during normal service to minimize costs. To do this successfully, the influence...... of electrical interference must be reduced. Tests are reported which characterize the nature of discharge and noise pulses when using capacitive couplers mounted on each of the phase leads and an RF current transformer mounted on the neutral lead for signal detection. Significant differences between PD...... and electrical noise have been observed....

  10. A Modular Approach for Teaching Partial Discharge Phenomenon through Experiment

    Science.gov (United States)

    Chatterjee, B.; Dey, D.; Chakravorti, S.

    2011-01-01

    Partial discharge (PD) monitoring is an effective predictive maintenance tool for electrical power equipment. As a result, an understanding of the theory related to PD and the associated measurement techniques is now necessary knowledge for power engineers in their professional life. This paper presents a modular course on PD phenomenon in which…

  11. Measurement of partial discharge inception characteristics in sub-cooled liquid nitrogen

    International Nuclear Information System (INIS)

    Koo, J.Y.; Lee, S.H.; Shin, W.J.; Khan, Umer A.; Oh, S.H.; Seong, J.K.; Lee, B.W.

    2011-01-01

    We measured partial discharge and partial discharge initiation voltage of subcooled liquid nitrogen. Various kinds of test samples have been prepared. Sub-cooled temperature in liquid nitrogen were changed. The number of PD pluses were decreased when 68 K liquid nitrogen was used. Sub-cooled liquid nitrogen has positive effects to suppress PD activities. Partial discharge (PD) measurement is one of the effective diagnostic techniques to predict abnormal high voltage dielectric insulation conditions of the electric equipments. PD diagnostic techniques were also could be utilized to evaluate the conditions of cryogenic dielectric insulation media of high temperature superconducting electric equipment in liquid nitrogen. Generally, liquid nitrogen at 77 K is used as cryogenic and dielectric media for high temperature superconducting devices for high voltage electric power systems. But due to generation of bubbles during quench conditions which cause harmful effect on the properties of liquid nitrogen insulation, sub-cooled nitrogen under 77 K was also employed to suppress bubble formation. In this work, investigation of PD characteristics of sub-cooled liquid nitrogen was conducted in order to clarify the relation between PD inception and the temperature of liquid nitrogen. It was observed that measured PDIV (PD inception voltage) shows little differences according to the sub-cooled temperature of liquid nitrogen, but the magnitude and total numbers of PD has been slightly decreased according the decrease of cooled temperature of liquid nitrogen. From experimental results, it was deduced that the sub-cooled liquid nitrogen from 68 K to 77 K, could be applicable without any considerations of the variation of PDIV.

  12. Partial oxidation of methane in a temperature-controlled dielectric barrier discharge reactor

    KAUST Repository

    Zhang, Xuming; Cha, Min

    2015-01-01

    We studied the relative importance of the reduced field intensity and the background reaction temperature in the partial oxidation of methane in a temperature-controlled dielectric barrier discharge reactor. We obtained important mechanistic insight

  13. Ageing of insulation and diagnosis of electrical equipment through detection of partial discharge

    International Nuclear Information System (INIS)

    Lopez Vergara, T.; Velasco Bernal, C.

    1994-01-01

    Ageing in electrical equipment affects mainly its insulation system. Such ageing in the insulation system is determined by its organic nature, basically constituted by three families of materials: cellulose, resin and hydrocarbon. All of these are affected by high temperatures, which tend to produce a break in the molecular chains (if the temperatures are not too high) or carbonization and gasification of the material (if they are). The radiation absorbed by the insulating materials also destroys molecular chains, causing degradation of the material. The break of the molecular chains, especially in the polymer-based materials, fragments the material, mainly in areas subjected to mechanical forces and stresses. From the electrical point of view, fissures occurring the insulating material lead to a much lower dielectric strength in certain parts of the materials, which could produce partial discharge conditions. Therefore, the growth of partial discharges in electrical equipment items is frequently the consequences of ageing, and be used to evaluate their residual life. Empresarios Agrupados has developed a system to detect partial discharges which can be used while equipment is still in operation. The measurements taken with this system are sufficiently accurate and repetitive to be used in evaluating the condition of medium-voltage electrical equipment insulation. (Author)

  14. On the Feasibility of Gap Detection of Power Transformer Partial Discharge UHF Signals: Gap Propagation Characteristics of Electromagnetic Waves

    OpenAIRE

    Xiaoxing Zhang; Guozhi Zhang; Yalong Li; Jian Zhang; Rui Huang

    2017-01-01

    This study analyzed the transformer electromagnetic gap propagation characteristics. The influence of gap size is also analyzed, and the results experimentally verified. The obtained results indicated that the gap propagation characteristics of electromagnetic wave signals radiated by the partial discharge (PD) source in different directions are substantially different. The intensity of the electromagnetic wave in the gap reaches a maximum at a gap height of 1 cm; and inside the gap, the inte...

  15. Wireless Sensor Network for Radiometric Detection and Assessment of Partial Discharge in High-Voltage Equipment

    Science.gov (United States)

    Upton, D. W.; Saeed, B. I.; Mather, P. J.; Lazaridis, P. I.; Vieira, M. F. Q.; Atkinson, R. C.; Tachtatzis, C.; Garcia, M. S.; Judd, M. D.; Glover, I. A.

    2018-03-01

    Monitoring of partial discharge (PD) activity within high-voltage electrical environments is increasingly used for the assessment of insulation condition. Traditional measurement techniques employ technologies that either require off-line installation or have high power consumption and are hence costly. A wireless sensor network is proposed that utilizes only received signal strength to locate areas of PD activity within a high-voltage electricity substation. The network comprises low-power and low-cost radiometric sensor nodes which receive the radiation propagated from a source of PD. Results are reported from several empirical tests performed within a large indoor environment and a substation environment using a network of nine sensor nodes. A portable PD source emulator was placed at multiple locations within the network. Signal strength measured by the nodes is reported via WirelessHART to a data collection hub where it is processed using a location algorithm. The results obtained place the measured location within 2 m of the actual source location.

  16. Antenna Deployment for the Localization of Partial Discharges in Open-Air Substations

    Science.gov (United States)

    Robles, Guillermo; Fresno, José Manuel; Sánchez-Fernández, Matilde; Martínez-Tarifa, Juan Manuel

    2016-01-01

    Partial discharges are ionization processes inside or on the surface of dielectrics that can unveil insulation problems in electrical equipment. The charge accumulated is released under certain environmental and voltage conditions attacking the insulation both physically and chemically. The final consequence of a continuous occurrence of these events is the breakdown of the dielectric. The electron avalanche provokes a derivative of the electric field with respect to time, creating an electromagnetic impulse that can be detected with antennas. The localization of the source helps in the identification of the piece of equipment that has to be decommissioned. This can be done by deploying antennas and calculating the time difference of arrival (TDOA) of the electromagnetic pulses. However, small errors in this parameter can lead to great displacements of the calculated position of the source. Usually, four antennas are used to find the source but the array geometry has to be correctly deployed to have minimal errors in the localization. This paper demonstrates, by an analysis based on simulation and also experimentally, that the most common layouts are not always the best options and proposes a simple antenna layout to reduce the systematic error in the TDOA calculation due to the positions of the antennas in the array. PMID:27092501

  17. Operation of Ferroelectric Plasma Sources in a Gas Discharge Mode

    International Nuclear Information System (INIS)

    Dunaevsky, A.; Fisch, N.J.

    2004-01-01

    Ferroelectric plasma sources in vacuum are known as sources of ablative plasma, formed due to surface discharge. In this paper, observations of a gas discharge mode of operation of the ferroelectric plasma sources (FPS) are reported. The gas discharge appears at pressures between approximately 20 and approximately 80 Torr. At pressures of 1-20 Torr, there is a transition from vacuum surface discharge to the gas discharge, when both modes coexist and the surface discharges sustain the gas discharge. At pressures between 20 and 80 Torr, the surface discharges are suppressed, and FPS operate in pure gas discharge mode, with the formation of almost uniform plasma along the entire surface of the ceramics between strips. The density of the expanding plasma is estimated to be about 1013 cm-3 at a distance of 5.5 mm from the surface. The power consumption of the discharge is comparatively low, making it useful for various applications. This paper also presents direct measurements of the yield of secondary electron emission from ferroelectric ceramics, which, at low energies of primary electrons, is high and dependent on the polarization of the ferroelectric material

  18. Development of acoustic partial discharge detection device; Bubun hoden kenshutsusochi wo riyo shita onkyo niyoru hendensetsubi no zetsuen rekka shindan gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Kiyoka [Kawasaki Steel Corp., Tokyo (Japan)

    1999-06-15

    This paper introduces an acoustic partial discharge detection device, consisting of a microphone, amplifier circuit for analog signals, A/D (Digital Signal Processor). This device has the following unique characteristics: (1) Judging whether or not there is partial discharge by analyzing supersonic signals. (2) High sensitivity for detecting discharge ; 100 pC from a distance of 1.2 m. (3)Locating the position of discharge occurrence by using a sharpe directional parabola microphone and laser beam pointer. The detector was used in the steel works to detect partial discharge on high-voltage electrical apparatus, where faults due to partial discharge were found in the potential transformer and current transformer. The effectiveness of the device was thus verified. (author)

  19. Characterization and comprehension of corona partial discharge in air under power frequency to very low frequency voltage

    Science.gov (United States)

    Yuanxiang, ZHOU; Zhongliu, ZHOU; Ling, ZHANG; Yunxiao, ZHANG; Yajun, MO; Jiantao, SUN

    2018-05-01

    For the partial discharge test of electrical equipment with large capacitance, the use of low-frequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply. However, the validity of PD test under low frequency voltage needs to be evaluated. In order to investigate the influence of voltage frequency on corona discharge in the air, the discharge test of the tip-plate electrode under the frequency from 50 to 0.1 Hz is carried out based on the impulse current method. The results show that some of the main features of corona under low frequency do not change. The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle. The magnitude of discharge and interval in positive cycle are random, while that in negative cycle are regular. With the decrease of frequency, the inception voltage increases. The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated, with discussion and interpretation from the aspects of space charge transportation, effective discharge time and transition of discharge modes. There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency. The experimental results can be the reference for mode identification of partial discharge under low frequency tests. The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency (usually 50 Hz). Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies.

  20. Shoulder replacement - discharge

    Science.gov (United States)

    Total shoulder arthroplasty - discharge; Endoprosthetic shoulder replacement - discharge; Partial shoulder replacement - discharge; Partial shoulder arthroplasty - discharge; Replacement - shoulder - discharge; Arthroplasty - shoulder - discharge

  1. Development and verification of a software tool for the acoustic location of partial discharge in a power transformer

    Directory of Open Access Journals (Sweden)

    Polužanski Vladimir

    2014-01-01

    Full Text Available This paper discusses the development and verification of software tool for determining the location of partial discharge in a power transformer with the acoustic method. Classification and systematization of physical principles and detection methods and tests of partial discharge in power transformers are shown at the beginning of this paper. The most important mathematical models, features, algorithms, and real problems that affect measurement accuracy are highlighted. This paper describes the development and implementation of a software tool for determining the location of partial discharge in a power transformer based on a no iterative mathematical algorithm. Verification and accuracy of measurement are proved both by computer simulation and experimental results available in the literature.

  2. Gas-discharge sources with charged particle emission from the plasma of glow discharge with a hollow cathode

    CERN Document Server

    Semenov, A P

    2001-01-01

    One studied properties of a magnetron discharge with a cold hollow and uncooled rod cathodes. One demonstrated the dominant effect of thermoelectron emission of a rod cathode heated in a discharge on characteristics of discharge and on emission properties of a gas-discharge plasma and the possibility pf a smooth transition of glow discharge to diffusion mode of arc discharge combustion. Paper describes sources of ions and electrons with improved physical and generalized design and engineering parameters. One shows the promise of the electrode structure of a hollow cathode magnetron discharge to be used as a source, in particular, of the atomic hydrogen and of atom flow of a working rod cathode

  3. Partial discharge measurements on 110kV current transformers. Setting the control value. Case study

    Science.gov (United States)

    Dan, C.; Morar, R.

    2017-05-01

    The case study presents a series of partial discharge measurements, reflecting the state of insulation of 110kV CURRENT TRANSFORMERS located in Sibiu county substations. Measurements were performed based on electrical method, using MPD600: an acquisition and analysis toolkit for detecting, recording, and analyzing partial discharges. MPD600 consists of one acquisition unit, an optical interface and a computer with dedicated software. The system allows measurements of partial discharge on site, even in presence of strong electromagnetic interferences because it provides synchronous acquisition from all measurement points. Therefore, measurements, with the ability to be calibrated, do render: - a value subject to interpretation according to IEC 61869-1:2007 + IEC 61869-2:2012 + IEC 61869-3:2011 + IEC 61869-5:2011 and IEC 60270: 2000; - the possibility to determine the quantitative limit of PD (a certain control value) to which the equipment can be operated safely and repaired with minimal costs (relative to the high costs implied by eliminating the consequences of a failure) identified empirically (process in which the instrument transformer subjected to the tests was completely destroyed).

  4. Calibration of ultra-high frequency (UHF) partial discharge sensors using FDTD method

    Science.gov (United States)

    Ishak, Asnor Mazuan; Ishak, Mohd Taufiq

    2018-02-01

    Ultra-high frequency (UHF) partial discharge sensors are widely used for conditioning monitoring and defect location in insulation system of high voltage equipment. Designing sensors for specific applications often requires an iterative process of manufacturing, testing and mechanical modifications. This paper demonstrates the use of finite-difference time-domain (FDTD) technique as a tool to predict the frequency response of UHF PD sensors. Using this approach, the design process can be simplified and parametric studies can be conducted in order to assess the influence of component dimensions and material properties on the sensor response. The modelling approach is validated using gigahertz transverse electromagnetic (GTEM) calibration system. The use of a transient excitation source is particularly suitable for modeling using FDTD, which is able to simulate the step response output voltage of the sensor from which the frequency response is obtained using the same post-processing applied to the physical measurement.

  5. Validation of mathematical models for predicting the swirling flow and the vortex rope in a Francis turbine operated at partial discharge

    DEFF Research Database (Denmark)

    Kuibin, P.A.; Okulov, Valery; Susan-Resiga, R.F.

    2010-01-01

    recover all this information without actually computing the full three-dimensional unsteady flow in the hydraulic turbine. As a result, we provide valuable mathematical tools for assessing the turbine behaviour at off-design operating regimes in the early stages of runner design, with computational effort......The vortex rope in a hydro turbine draft tube is one the main and strong sources of pulsations in non-optimal modes of hydro turbine operation. We examine the case of a Francis turbine model operated at partial discharge, where a strong precessing vortex rope is developed in the discharge cone...... several orders of magnitude less than the current approaches of simulating the complex turbine flow....

  6. Influence of Nanosilica Filler Content in LDPE Composites on Partial Discharge Characteristics

    Institute of Scientific and Technical Information of China (English)

    Z. Abdul-Malek; A.M. Azzin; Y.Z. Ariel; Aulia; K.Y. Lau; M. Jaafar

    2011-01-01

    Partial discharges (PDs) due to artificial void in samples of LDPE nanocomposite sheet have been investiga- ted in this work. PDs may cause the degradation of insulating materials and may affect the lifetime of high-voltage ap- paratus. An experimental work using sphere ball-plane electrode system (CIGRE Method II) and a 1.0 mm LDPE composite sheet was carried out. Different weight percentages of nanosilica (0%, 2%, 4%, 6% and 8%) were used. PD experimental results, such as PD magnitude and PD number (both PD pulse polarities), as functions of the ap- plied stress duration at a specified applied voltage were compared. The surface morphology of specimens was also presented and this conforms to the PD findings. The experimental results show that the PD characteristics of the LDPE generally improve with the introduction of nanosilica, the composite with the highest content of filler, namely the 8% (wt) nanosilica sample has the least partial discharge activities.

  7. Confined discharge plasma sources for Z-pinch experiments

    International Nuclear Information System (INIS)

    Hinshelwood, D.D.; Goodrich, P.J.; Mehlman, G.; Scherrer, V.E.; Stephanakis, S.J.; Young, F.C.

    1989-01-01

    The authors report their investigation Z-pinch implosions on the NRL Gamble II generator using metallic sources of sodium and aluminum, and non-metallic source of sodium (NaF), magnesium (MgF 2 ), and aluminum (Al 2 0 3 ). For 1 MA driving currents, peak Κ-shell radiated powers of about 100 GW and energies of about 1.5 kj have been obtained with both pure aluminum and NaF implosions. The aluminum results are comparable to those in previous Gamble II experiments with aluminum wire arrays. Confined discharge sources have been used to generate tens of GW in the Na Heα pump line and flourescence of the neon has been observed. The effects of nozzle shape and size, chamber diameter, amount of fuse material, and confined discharge current have been investigated in Gamble II implosion experiments. These studies indicate that confined discharge sources are capable of supplying significantly more material than required for implosions at the 1 MA level, so that this technique could be extended to higher current generators

  8. Partial discharges within two spherical voids in an epoxy resin

    International Nuclear Information System (INIS)

    Illias, H A; Mokhlis, H; Tunio, M A; Chen, G; Bakar, A H A

    2013-01-01

    A void in a dielectric insulation material may exist due to imperfection in the insulation manufacturing or long term stressing. Voids have been identified as one of the common sources of partial discharge (PD) activity within an insulation system, such as in cable insulation and power transformers. Therefore, it is important to study PD phenomenon within void cavities in insulation. In this work, a model of PD activity within two spherical voids in a homogeneous dielectric material has been developed using finite element analysis software to study the parameters affecting PD behaviour. The parameters that have been taken into account are the void surface conductivity, electron generation rate and the inception and extinction fields. Measurements of PD activity within two spherical voids in an epoxy resin under ac sinusoidal applied voltage have also been performed. The simulation results have been compared with the measurement data to validate the model and to identify the parameters affecting PD behaviour. Comparison between measurements of PD activity within single and two voids in a dielectric material have also been made to observe the difference of the results under both conditions. (paper)

  9. Analysis of Partial Discharge Activity for Evaluation of the State of High Power Electric Generators Stator Windings

    Directory of Open Access Journals (Sweden)

    Dumitrescu Sorin

    2016-08-01

    Full Text Available The paper shows the importance of trending of partial discharge activity in assessing the insulation condition. It is presented the principle of the measurement method and the quantities that characterize partial discharges and also the criteria utilized for the assessement of the insulation condition of the hydrogenerators. Results of the measurements made on several hydrogenerators are presented, like the variation with time of the two main quantities that characterize the partial discharges, maximum magnitude, Qm and the normalized quantity, NQN over a period of about 10 years. Further, a classification of the insulation condition by 3 main and 2 intermediary categories and the definition of these categories are given. The criteria used for the assessment of the insulation condition are presented in the form of a table: quantitative criteria by the ± NQN and ± Qm values and qualitative criteria for the analysis of the 2D and 3D diagrams. At the end of each set of measurements, an analyze of the insulation condition annual evaluation is made, also a verdict is put, and of course, the recommendations made relating to the maintenance and the decisions that have been taken. The paper ends with several considerations on the method of on-line partial discharges and especially, on the conditions for valid trending activity in time.

  10. Influence of discharge gap on the discharge stability in a short vacuum arc ion source

    Energy Technology Data Exchange (ETDEWEB)

    Chen, L. [Institute of Electronic Engineering, China Academy of Engineering Physics, Mianyang, Sichuan 621900 (China); Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Zhang, G. L.; Jin, D. Z.; Dai, J. Y. [Institute of Electronic Engineering, China Academy of Engineering Physics, Mianyang, Sichuan 621900 (China); Yang, L. [Institute of Nuclear Science and Technology, Louzhou University, Lanzhou, Gansu 730000 (China)

    2012-02-15

    The influence of the discharge gap between cathode and anode on the discharge stability in a short vacuum arc (SVA) ion source is presented in this paper. Planar cathode and cylindrical hollow anode made of titanium are investigated. There is a great need in present accelerator injection research for SVA source to produce the small deviation of the ion current beam. Current research shows that increasing the short discharge gap can reduce the level of ion current deviation and ion charge deviation from 29% and 31% to 15% and 17%, respectively. A microplasma plume generation mechanism in SVA and scanning electron microscopic results can be used to explain this interesting phenomenon.

  11. Large area, surface discharge pumped, vacuum ultraviolet light source

    Science.gov (United States)

    Sze, R.C.; Quigley, G.P.

    1996-12-17

    Large area, surface discharge pumped, vacuum ultraviolet (VUV) light source is disclosed. A contamination-free VUV light source having a 225 cm{sup 2} emission area in the 240-340 nm region of the electromagnetic spectrum with an average output power in this band of about 2 J/cm{sup 2} at a wall-plug efficiency of approximately 5% is described. Only ceramics and metal parts are employed in this surface discharge source. Because of the contamination-free, high photon energy and flux, and short pulse characteristics of the source, it is suitable for semiconductor and flat panel display material processing. 3 figs.

  12. Improving detection sensitivity for partial discharge monitoring of high voltage equipment

    Science.gov (United States)

    Hao, L.; Lewin, P. L.; Swingler, S. G.

    2008-05-01

    Partial discharge (PD) measurements are an important technique for assessing the health of power apparatus. Previous published research by the authors has shown that an electro-optic system can be used for PD measurement of oil-filled power transformers. A PD signal generated within an oil-filled power transformer may reach a winding and then travel along the winding to the bushing core bar. The bushing, acting like a capacitor, can transfer the high frequency components of the partial discharge signal to its earthed tap point. Therefore, an effective PD current measurement can be implemented at the bushing tap by using a radio frequency current transducer around the bushing-tap earth connection. In addition, the use of an optical transmission technique not only improves the electrical noise immunity and provides the possibility of remote measurement but also realizes electrical isolation and enhances safety for operators. However, the bushing core bar can act as an aerial and in addition noise induced by the electro-optic modulation system may influence overall measurement sensitivity. This paper reports on a machine learning technique, namely the use of a support vector machine (SVM), to improve the detection sensitivity of the system. Comparison between the signal extraction performances of a passive hardware filter and the SVM technique has been assessed. The results obtained from the laboratory-based experiment have been analysed and indicate that the SVM approach provides better performance than the passive hardware filter and it can reliably detect discharge signals with apparent charge greater than 30 pC.

  13. Improving detection sensitivity for partial discharge monitoring of high voltage equipment

    International Nuclear Information System (INIS)

    Hao, L; Lewin, P L; Swingler, S G

    2008-01-01

    Partial discharge (PD) measurements are an important technique for assessing the health of power apparatus. Previous published research by the authors has shown that an electro-optic system can be used for PD measurement of oil-filled power transformers. A PD signal generated within an oil-filled power transformer may reach a winding and then travel along the winding to the bushing core bar. The bushing, acting like a capacitor, can transfer the high frequency components of the partial discharge signal to its earthed tap point. Therefore, an effective PD current measurement can be implemented at the bushing tap by using a radio frequency current transducer around the bushing-tap earth connection. In addition, the use of an optical transmission technique not only improves the electrical noise immunity and provides the possibility of remote measurement but also realizes electrical isolation and enhances safety for operators. However, the bushing core bar can act as an aerial and in addition noise induced by the electro-optic modulation system may influence overall measurement sensitivity. This paper reports on a machine learning technique, namely the use of a support vector machine (SVM), to improve the detection sensitivity of the system. Comparison between the signal extraction performances of a passive hardware filter and the SVM technique has been assessed. The results obtained from the laboratory-based experiment have been analysed and indicate that the SVM approach provides better performance than the passive hardware filter and it can reliably detect discharge signals with apparent charge greater than 30 pC

  14. Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated Switchgears

    Directory of Open Access Journals (Sweden)

    Guoming Wang

    2017-11-01

    Full Text Available With the increasing demand for precise condition monitoring and diagnosis of gas-insulated switchgears (GISs, it has become a challenge to improve the detection sensitivity of partial discharge (PD induced in the GIS spacer. This paper deals with the elimination of the capacitive component from the phase-resolved partial discharge (PRPD signal generated in GIS spacers based on discrete wavelet transform (WT. Three types of typical insulation defects were simulated using PD cells. The single PD pulses were detected and were further used to determine the optimal mother wavelet. As a result, the bior6.8 was selected to decompose the PD signal into 8 levels and the signal energy at each level was calculated. The decomposed components related with capacitive disturbance were discarded, whereas those associated with PD were de-noised by a threshold and a thresholding function. Finally, the PRPD signals were reconstructed using the de-noised components.

  15. [Automatic adjustment control system for DC glow discharge plasma source].

    Science.gov (United States)

    Wan, Zhen-zhen; Wang, Yong-qing; Li, Xiao-jia; Wang, Hai-zhou; Shi, Ning

    2011-03-01

    There are three important parameters in the DC glow discharge process, the discharge current, discharge voltage and argon pressure in discharge source. These parameters influence each other during glow discharge process. This paper presents an automatic control system for DC glow discharge plasma source. This system collects and controls discharge voltage automatically by adjusting discharge source pressure while the discharge current is constant in the glow discharge process. The design concept, circuit principle and control program of this automatic control system are described. The accuracy is improved by this automatic control system with the method of reducing the complex operations and manual control errors. This system enhances the control accuracy of glow discharge voltage, and reduces the time to reach discharge voltage stability. The glow discharge voltage stability test results with automatic control system are provided as well, the accuracy with automatic control system is better than 1% FS which is improved from 4% FS by manual control. Time to reach discharge voltage stability has been shortened to within 30 s by automatic control from more than 90 s by manual control. Standard samples like middle-low alloy steel and tin bronze have been tested by this automatic control system. The concentration analysis precision has been significantly improved. The RSDs of all the test result are better than 3.5%. In middle-low alloy steel standard sample, the RSD range of concentration test result of Ti, Co and Mn elements is reduced from 3.0%-4.3% by manual control to 1.7%-2.4% by automatic control, and that for S and Mo is also reduced from 5.2%-5.9% to 3.3%-3.5%. In tin bronze standard sample, the RSD range of Sn, Zn and Al elements is reduced from 2.6%-4.4% to 1.0%-2.4%, and that for Si, Ni and Fe is reduced from 6.6%-13.9% to 2.6%-3.5%. The test data is also shown in this paper.

  16. 40 CFR 122.29 - New sources and new dischargers.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false New sources and new dischargers. 122.29 Section 122.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS EPA ADMINISTERED PERMIT PROGRAMS: THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Permit...

  17. Partial oxidation of methane in a temperature-controlled dielectric barrier discharge reactor

    KAUST Repository

    Zhang, Xuming

    2015-01-01

    We studied the relative importance of the reduced field intensity and the background reaction temperature in the partial oxidation of methane in a temperature-controlled dielectric barrier discharge reactor. We obtained important mechanistic insight from studying high-temperature and low-pressure conditions with similar reduced field intensities. In the tested range of background temperatures (297 < T < 773 K), we found that the conversion of methane and oxygen depended on both the electron-induced chemistry and the thermo-chemistry, whereas the chemical pathways to the products were overall controlled by the thermo-chemistry at a given temperature. We also found that the thermo-chemistry enhanced the plasma-assisted partial oxidation process. Our findings expand our understanding of the plasma-assisted partial oxidation process and may be helpful in the design of cost-effective plasma reformers. © 2014 The Combustion Institute.

  18. Online calibration of high-frequency partial discharge signals in three-phase belted power cables

    NARCIS (Netherlands)

    Wouters, P.A.A.F.

    2005-01-01

    Partial discharge (PD) magnitudes from classical detection techniques are expressed in terms of apparent charges. Signals from HF/VHF/UHF techniques on substation components are often hard to express in this quantity because of complex signal excitation and propagation channels. A method to

  19. Technological plasma source equipped with combined system of vacuum-arc discharge initiation

    International Nuclear Information System (INIS)

    Sysoev, Yu.O.

    2013-01-01

    The construction and the operation principle of erosion plasma source with a three-stage system of vacuum-arc discharge excitation is described. As first two step was used the modified contactless start system with plasma injector, which was widely used in standard plasma sources of the ''Bulat'' systems. The operation principle of the third stage was based on the transition of glow discharge to arc discharge. Coordinated operation of three stages during various stages of coating deposition provided significant increasing of service life and reliability of the system of vacuum-arc discharge initiation and extended the functionality of the plasma source

  20. Classification of Partial Discharge Measured under Different Levels of Noise Contamination.

    Directory of Open Access Journals (Sweden)

    Wong Jee Keen Raymond

    Full Text Available Cable joint insulation breakdown may cause a huge loss to power companies. Therefore, it is vital to diagnose the insulation quality to detect early signs of insulation failure. It is well known that there is a correlation between Partial discharge (PD and the insulation quality. Although many works have been done on PD pattern recognition, it is usually performed in a noise free environment. Also, works on PD pattern recognition in actual cable joint are less likely to be found in literature. Therefore, in this work, classifications of actual cable joint defect types from partial discharge data contaminated by noise were performed. Five cross-linked polyethylene (XLPE cable joints with artificially created defects were prepared based on the defects commonly encountered on site. Three different types of input feature were extracted from the PD pattern under artificially created noisy environment. These include statistical features, fractal features and principal component analysis (PCA features. These input features were used to train the classifiers to classify each PD defect types. Classifications were performed using three different artificial intelligence classifiers, which include Artificial Neural Networks (ANN, Adaptive Neuro-Fuzzy Inference System (ANFIS and Support Vector Machine (SVM. It was found that the classification accuracy decreases with higher noise level but PCA features used in SVM and ANN showed the strongest tolerance against noise contamination.

  1. Technical advancements in the integration of online partial discharge monitoring in distribution cable networks

    NARCIS (Netherlands)

    Wagenaars, P.; Wouters, P.A.A.F.; Wielen, van der P.C.J.M.; Steennis, F.

    2009-01-01

    Online partial discharge (PD) detection and location systems for medium-voltage (MV) cables have been developed over the past years and are currently introduced by utilities on an increasingly large scale. This paper addresses a few of the new challenges related to the integration of these systems

  2. Investigation of gas discharge ion sources for on-line mass separation

    International Nuclear Information System (INIS)

    Kirchner, R.

    1976-03-01

    The development of efficient gas discharge ion sources with axial beam extraction for on-line mass separation is described. The aim of the investigation was to increase the ion source temperature, the lifetime and the ionisation yield in comparison to present low-pressure are discharge ion sources and to reduce the ion current density from usually 1 to 100 mA/cm 3 . In all ion sources the pressure range below the minimal ignition pressure of the arc discharge was investigated. As a result an ion source was developed which works at small changes in geometry and in electric device of a Nielsen source with high ionization yield (up to 50% for xenon) stabil and without ignition difficulties up to 10 -5 Torr. At a typical pressure of 3 x 10 -5 Torr ion current and ion current density are about 1 μA and 0.1 mA/cm 3 respectively besides high yield and a great emission aperture (diameter 1.2 mm). (orig.) [de

  3. Combined corona discharge and UV photoionization source for ion mobility spectrometry.

    Science.gov (United States)

    Bahrami, Hamed; Tabrizchi, Mahmoud

    2012-08-15

    An ion mobility spectrometer is described which is equipped with two non-radioactive ion sources, namely an atmospheric pressure photoionization and a corona discharge ionization source. The two sources cannot only run individually but are additionally capable of operating simultaneously. For photoionization, a UV lamp was mounted parallel to the axis of the ion mobility cell. The corona discharge electrode was mounted perpendicular to the UV radiation. The total ion current from the photoionization source was verified as a function of lamp current, sample flow rate, and drift field. Simultaneous operation of the two ionization sources was investigated by recording ion mobility spectra of selected samples. The design allows one to observe peaks from either the corona discharge or photoionization individually or simultaneously. This makes it possible to accurately compare peaks in the ion mobility spectra from each individual source. Finally, the instrument's capability for discriminating two peaks appearing in approximately identical drift times using each individual ionization source is demonstrated. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Partial Discharge Measurements in HV Rotating Machines in Dependence on Pressure of Coolant

    Directory of Open Access Journals (Sweden)

    I. Kršňák

    2002-01-01

    Full Text Available The influence of the pressure of the coolant used in high voltage rotating machines on partial discharges occurring in stator insulation is discussed in this paper. The first part deals with a theoretical analysis of the topic. The second part deals with the results obtained on a real generator in industrial conditions. Finally, theoretical assumptions and obtained results are compared.

  5. Influence of bulk dielectric polarization upon partial discharge transients effect of heterogeneous dielectric geometry

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Crichton, George C.

    2000-01-01

    A physically valid theory of partial discharge (PD) transients is based upon the concept of the charge induced upon the detecting electrode by the PD. This induced charge consists of two components. One is associated with the actual space charge in the void, while the other is related to changes...

  6. Virtual-Instrument-Based Online Monitoring System for Hands-on Laboratory Experiment of Partial Discharges

    Science.gov (United States)

    Karmakar, Subrata

    2017-01-01

    Online monitoring of high-voltage (HV) equipment is a vital tool for early detection of insulation failure. Most insulation failures are caused by partial discharges (PDs) inside the HV equipment. Because of the very high cost of establishing HV equipment facility and the limitations of electromagnetic interference-screened laboratories, only a…

  7. Extreme-UV electrical discharge source

    Science.gov (United States)

    Fornaciari, Neal R.; Nygren, Richard E.; Ulrickson, Michael A.

    2002-01-01

    An extreme ultraviolet and soft x-ray radiation electric capillary discharge source that includes a boron nitride housing defining a capillary bore that is positioned between two electrodes one of which is connected to a source of electric potential can generate a high EUV and soft x-ray radiation flux from the capillary bore outlet with minimal debris. The electrode that is positioned adjacent the capillary bore outlet is typically grounded. Pyrolytic boron nitride, highly oriented pyrolytic boron nitride, and cubic boron nitride are particularly suited. The boron nitride capillary bore can be configured as an insert that is encased in an exterior housing that is constructed of a thermally conductive material. Positioning the ground electrode sufficiently close to the capillary bore outlet also reduces bore erosion.

  8. Defect Pattern Recognition Based on Partial Discharge Characteristics of Oil-Pressboard Insulation for UHVDC Converter Transformer

    Directory of Open Access Journals (Sweden)

    Wen Si

    2018-03-01

    Full Text Available The ultra high voltage direct current (UHVDC transmission system has advantages in delivering electrical energy over long distance at high capacity. UHVDC converter transformer is a key apparatus and its insulation state greatly affects the safe operation of the transmission system. Partial discharge (PD characteristics of oil-pressboard insulation under combined AC-DC voltage are the foundation for analyzing the insulation state of UHVDC converter transformers. The defect pattern recognition based on PD characteristics is an important part of the state monitoring of converter transformers. In this paper, PD characteristics are investigated with the established experimental platform of three defect models (needle-plate, surface discharge and air gap under 1:1 combined AC-DC voltage. The different PD behaviors of three defect models are discussed and explained through simulation of electric field strength distribution and discharge mechanism. For the recognition of defect types when multiple types of sources coexist, the Random Forests algorithm is used for recognition. In order to reduce the computational layer and the loss of information caused by the extraction of traditional features, the preprocessed single PD pulses and phase information are chosen to be the features for learning and test. Zero-padding method is discussed for normalizing the features. Based on the experimental data, Random Forests and Least Squares Support Vector Machine are compared in the performance of computing time, recognition accuracy and adaptability. It is proved that Random Forests is more suitable for big data analysis.

  9. Discharge behavior of vacuum arc ion source working in pulse mode

    International Nuclear Information System (INIS)

    Tang Pingying; Dai Jingyi; Tan Xiaohua; Jin Dazhi; Liu Tie; Ding Bonan

    2005-01-01

    Discharge behavior of the vacuum arc ion source working in pulse mode was investigated using high-speed photography and spectrum diagnosis. The evolvement of cathode spot on hydrogen-impregnated electrode was captured by high-speed photography, and the emission spectra of cathode spot at different pulse currents were analyzed. The experimental results show that in most cases, only one cathode spot can be found in the discharge zone of vacuum arc ion source, and the spot moves a little during the same discharge. Temperature of the cathode spot may rise while the discharge current increases, and ultimately the density of hydrogen ion will be increased. At the same time, sputtering of the electrode is enhanced and the quality of ion plasma will be reduced. (authors)

  10. Partial Discharge Spectral Characterization in HF, VHF and UHF Bands Using Particle Swarm Optimization.

    Science.gov (United States)

    Robles, Guillermo; Fresno, José Manuel; Martínez-Tarifa, Juan Manuel; Ardila-Rey, Jorge Alfredo; Parrado-Hernández, Emilio

    2018-03-01

    The measurement of partial discharge (PD) signals in the radio frequency (RF) range has gained popularity among utilities and specialized monitoring companies in recent years. Unfortunately, in most of the occasions the data are hidden by noise and coupled interferences that hinder their interpretation and renders them useless especially in acquisition systems in the ultra high frequency (UHF) band where the signals of interest are weak. This paper is focused on a method that uses a selective spectral signal characterization to feature each signal, type of partial discharge or interferences/noise, with the power contained in the most representative frequency bands. The technique can be considered as a dimensionality reduction problem where all the energy information contained in the frequency components is condensed in a reduced number of UHF or high frequency (HF) and very high frequency (VHF) bands. In general, dimensionality reduction methods make the interpretation of results a difficult task because the inherent physical nature of the signal is lost in the process. The proposed selective spectral characterization is a preprocessing tool that facilitates further main processing. The starting point is a clustering of signals that could form the core of a PD monitoring system. Therefore, the dimensionality reduction technique should discover the best frequency bands to enhance the affinity between signals in the same cluster and the differences between signals in different clusters. This is done maximizing the minimum Mahalanobis distance between clusters using particle swarm optimization (PSO). The tool is tested with three sets of experimental signals to demonstrate its capabilities in separating noise and PDs with low signal-to-noise ratio and separating different types of partial discharges measured in the UHF and HF/VHF bands.

  11. Emission characteristics of laser ablation-hollow cathode glow discharge spectral source

    Directory of Open Access Journals (Sweden)

    Karatodorov Stefan

    2014-11-01

    Full Text Available The emission characteristics of a scheme combining laser ablation as sample introduction source and hollow cathode discharge as excitation source are presented. The spatial separation of the sample material introduction by laser ablation and hollow cathode excitation is achieved by optimizing the gas pressure and the sample-cathode gap length. At these conditions the discharge current is maximized to enhance the analytical lines intensity.

  12. Electrical discharge light sources: a challenge for the future

    International Nuclear Information System (INIS)

    Zissis, G.

    2001-01-01

    The first electric powder lamp operated that 150 years ago, since then the evolution of light sources is astonishing. Today, more than 10 % of the global electric power produced worldwide serve fore light production from several billions lamps. Since last three decades incandescent lamps are gradually replaced by more energy efficient discharge lamps. In parallel, new generation of light emitting diodes, producing bright colours (including white) with luminous efficacy challenging even discharge lamps, appeared in past years. The objective of this paper is to focus on the state of art in the domain of light sources and discuss the challenges for the near future. (author)

  13. PREFACE: Diagnostics for electrical discharge light sources: pushing the limits Diagnostics for electrical discharge light sources: pushing the limits

    Science.gov (United States)

    Zissis, Georges; Haverlag, Marco

    2010-06-01

    Light sources play an indispensable role in the daily life of any human being. Quality of life, health and urban security related to traffic and crime prevention depend on light and on its quality. In fact, every day approximately 30 billion electric light sources operate worldwide. These electric light sources consume almost 19% of worldwide electricity production. Finding new ways to light lamps is a challenge where the stakes are scientific, technological, economic and environmental. The production of more efficient light sources is a sustainable solution for humanity. There are many opportunities for not only enhancing the efficiency and reliability of lighting systems but also for improving the quality of light as seen by the end user. This is possible through intelligent use of new technologies, deep scientific understanding of the operating principles of light sources and knowledge of the varied human requirements for different types of lighting in different settings. A revolution in the domain of light source technology is on the way: high brightness light emitting diodes arriving in the general lighting market, together with organic LEDs (OLEDs), are producing spectacular advances. However, unlike incandescence, electrical discharge lamps are far from disappearing from the market. In addition, new generations of discharge lamps based on molecular radiators are becoming a reality. There are still many scientific and technological challenges to be raised in this direction. Diagnostics are important for understanding the fundamental mechanisms taking place in the discharge plasma. This understanding is an absolute necessity for system optimization leading to more efficient and high quality light sources. The studied medium is rather complex, but new diagnostic techniques coupled to innovative ideas and powerful tools have been developed in recent years. This cluster issue of seven papers illustrates these efforts. The selected papers cover all domains, from

  14. Optical fiber sensor of partial discharges in High Voltage DC experiments

    Science.gov (United States)

    Búa-Núñez, I.; Azcárraga-Ramos, C. G.; Posada-Román, J. E.; Garcia-Souto, J. A.

    2014-05-01

    A setup simulating High Voltage DC (HVDC) transformers barriers was developed to demonstrate the effectiveness of an optical fiber (OF) sensor in detecting partial discharges (PD) under these peculiar conditions. Different PD detection techniques were compared: electrical methods, and acoustic methods. Standard piezoelectric sensors (R15i-AST) and the above mentioned OF sensors were used for acoustic detection. The OF sensor was able to detect PD acoustically with a sensitivity better than the other detection methods. The multichannel instrumentation system was tested in real HVDC conditions with the aim of analyzing the behavior of the insulation (mineral oil/pressboard).

  15. Influence of bulk dielectric polarization upon partial discharge transients: Effect of void geometry and orientation

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Crichton, G.C.

    2005-01-01

    The induced charge arising from a partial discharge consists of 2 components. One is associated with the actual space charge in the void. The other is related to changes in the polarization of the bulk dielectric. These changes are a direct consequence of the field produced by the space charge...

  16. Partial discharge early-warning through ultraviolet spectroscopic detection of SO2

    International Nuclear Information System (INIS)

    Zhao, Yu; Wang, Xianpei; Dai, Dangdang; Dong, Zhengcheng; Huang, Yunguang

    2014-01-01

    Surveillance of SF 6  decomposition products is significant for detection of partial discharge (PD) in gas insulation switchgear (GIS). As a basis in on-site detection and diagnosis, PD early-warning aims to quickly find the abnormalities using a simple and cheap device. In this paper, SO 2  is chosen as a feature product and detected through ultraviolet spectroscopy. The derivative method is employed for baseline correction and spectral enhancement. The standard gases of the main decomposition products are qualitatively and quantitatively detected. Then decomposition experiments with different defects are designed to further verify the feasibility. As a stable decomposition product under PD, SO 2  is proved to be applicable for PD early-warning in the field. By selecting the appropriate wavelength range, namely 290–310 nm, ultraviolet derivative spectroscopy is sensitive enough to the trace SO 2  in the decomposed gas and the interference of other products can be avoided. Fast Fourier transform could be used for feature extraction in qualitative detection. Concentrations of SO 2  and other by-products increase with increasing discharge time and could be affected by the discharge energy and PD type. Ultraviolet detection based on SO 2  is effective for PD early-warning but the threshold should still be carefully selected in practice. (paper)

  17. Partial discharge characteristics of polymer nanocomposite materials in electrical insulation: a review of sample preparation techniques, analysis methods, potential applications, and future trends.

    Science.gov (United States)

    Izzati, Wan Akmal; Arief, Yanuar Z; Adzis, Zuraimy; Shafanizam, Mohd

    2014-01-01

    Polymer nanocomposites have recently been attracting attention among researchers in electrical insulating applications from energy storage to power delivery. However, partial discharge has always been a predecessor to major faults and problems in this field. In addition, there is a lot more to explore, as neither the partial discharge characteristic in nanocomposites nor their electrical properties are clearly understood. By adding a small amount of weight percentage (wt%) of nanofillers, the physical, mechanical, and electrical properties of polymers can be greatly enhanced. For instance, nanofillers in nanocomposites such as silica (SiO2), alumina (Al2O3) and titania (TiO2) play a big role in providing a good approach to increasing the dielectric breakdown strength and partial discharge resistance of nanocomposites. Such polymer nanocomposites will be reviewed thoroughly in this paper, with the different experimental and analytical techniques used in previous studies. This paper also provides an academic review about partial discharge in polymer nanocomposites used as electrical insulating material from previous research, covering aspects of preparation, characteristics of the nanocomposite based on experimental works, application in power systems, methods and techniques of experiment and analysis, and future trends.

  18. Effectiveness of Partition and Graph Theoretic Clustering Algorithms for Multiple Source Partial Discharge Pattern Classification Using Probabilistic Neural Network and Its Adaptive Version: A Critique Based on Experimental Studies

    Directory of Open Access Journals (Sweden)

    S. Venkatesh

    2012-01-01

    Full Text Available Partial discharge (PD is a major cause of failure of power apparatus and hence its measurement and analysis have emerged as a vital field in assessing the condition of the insulation system. Several efforts have been undertaken by researchers to classify PD pulses utilizing artificial intelligence techniques. Recently, the focus has shifted to the identification of multiple sources of PD since it is often encountered in real-time measurements. Studies have indicated that classification of multi-source PD becomes difficult with the degree of overlap and that several techniques such as mixed Weibull functions, neural networks, and wavelet transformation have been attempted with limited success. Since digital PD acquisition systems record data for a substantial period, the database becomes large, posing considerable difficulties during classification. This research work aims firstly at analyzing aspects concerning classification capability during the discrimination of multisource PD patterns. Secondly, it attempts at extending the previous work of the authors in utilizing the novel approach of probabilistic neural network versions for classifying moderate sets of PD sources to that of large sets. The third focus is on comparing the ability of partition-based algorithms, namely, the labelled (learning vector quantization and unlabelled (K-means versions, with that of a novel hypergraph-based clustering method in providing parsimonious sets of centers during classification.

  19. Partial discharges and breakdown in C3F8

    International Nuclear Information System (INIS)

    Koch, M; Franck, C M

    2014-01-01

    Traditional search processes of gases or gas mixtures for replacing SF 6 involve time consuming measurements of partial discharges and breakdown behaviour for several voltage waveforms and different field configurations. Recently a model for prediction of this behaviour for SF 6 was described in literature. The model only requires basic properties of the gas such as the critical field strength and the effective ionization coefficient, which can be obtained by swarm parameter measurements, and thermodynamic properties, which can be calculated. In this paper, we show for the well-known and electronegative gas octafluoropropane (C 3 F 8 ) that it is possible to transfer the model developed for SF 6 to this gas to describe the breakdown behaviour of C 3 F 8 . Thus the model can be beneficial in the screening process of new insulation gases. (paper)

  20. Partial discharges and breakdown in C3F8

    Science.gov (United States)

    Koch, M.; Franck, C. M.

    2014-10-01

    Traditional search processes of gases or gas mixtures for replacing SF6 involve time consuming measurements of partial discharges and breakdown behaviour for several voltage waveforms and different field configurations. Recently a model for prediction of this behaviour for SF6 was described in literature. The model only requires basic properties of the gas such as the critical field strength and the effective ionization coefficient, which can be obtained by swarm parameter measurements, and thermodynamic properties, which can be calculated. In this paper, we show for the well-known and electronegative gas octafluoropropane (C3F8) that it is possible to transfer the model developed for SF6 to this gas to describe the breakdown behaviour of C3F8. Thus the model can be beneficial in the screening process of new insulation gases.

  1. [The glow discharge as an atomization and ionization source

    International Nuclear Information System (INIS)

    1990-01-01

    This is to summarize the research progress in this project at the University of Florida over the past 13 months. In keeping with the directions of the Federal Demonstration Project, the report will be brief, presenting an overview of the major findings. We have continued the study of the glow discharge, primarily as an ionization source for elemental analysis. Glow discharge interest continues to grow in the analytical chemistry community as evidenced by the number of special symposia at major conferences, by the new researchers entering the field, and by the introduction of new instrumentation. There is little doubt that glow discharge mass spectrometry, for example, is now a major technique in the elemental analysis of solids

  2. A double-stage pulsed discharge fluorine atom beam source

    International Nuclear Information System (INIS)

    Ren Zefeng; Qiu Minghui; Che Li; Dai Dongxu; Wang Xiuyan; Yang Xueming

    2006-01-01

    Molecular-beam intensity and speed ratio are two major limiting factors in many molecular-beam experiments. This article reports a high-intensity, high-speed-ratio, pulsed supersonic fluorine atom beam source using a double-stage discharge beam source. Its performance is indicated by the high-resolution time-of-flight spectrum in the crossed beam experiment of F( 2 P)+para-H 2

  3. Capillary discharge sources of hard UV radiation

    International Nuclear Information System (INIS)

    Cachoncinlle, C; Dussart, R; Robert, E; Goetze, S; Pons, J; Mohanty, S R; Viladrosa, R; Fleurier, C; Pouvesle, J M

    2002-01-01

    We developed and studied three different extreme ultraviolet (EUV) capillary discharge sources either dedicated to the generation of coherent or incoherent EUV radiation. The CAPELLA source has been developed especially as an EUV source for the metrology at 13.4 nm. With one of these sources, we were able to produce gain on the Balmer-Hα (18.22 nm) and Hβ (13.46 nm) spectral lines in carbon plasma. By injecting 70 GW cm -3 we measured gain-length products up to 1.62 and 3.02 for the Hα and Hβ, respectively optimization of the EUV capillary source CAPELLA led to the development of an EUV lamp which emits 2 mJ in the bandwidth of the MoSi mirror, per joule stored, per shot and in full solid angle. The wall-plug efficiency is 0.2%. Stability of this lamp is better than 4% and the lamp can operate at repetition rate of 50 Hz

  4. Artificial Neural Network Application for Partial Discharge Recognition: Survey and Future Directions

    Directory of Open Access Journals (Sweden)

    Abdullahi Abubakar Mas’ud

    2016-07-01

    Full Text Available In order to investigate how artificial neural networks (ANNs have been applied for partial discharge (PD pattern recognition, this paper reviews recent progress made on ANN development for PD classification by a literature survey. Contributions from several authors have been presented and discussed. High recognition rate has been recorded for several PD faults, but there are still many factors that hinder correct recognition of PD by the ANN, such as high-amplitude noise or wide spectral content typical from industrial environments, trial and error approaches in determining an optimum ANN, multiple PD sources acting simultaneously, lack of comprehensive and up to date databank of PD faults, and the appropriate selection of the characteristics that allow a correct recognition of the type of source which are currently being addressed by researchers. Several suggestions for improvement are proposed by the authors include: (1 determining the optimum weights in training the ANN; (2 using PD data captured over long stressing period in training the ANN; (3 ANN recognizing different PD degradation levels; (4 using the same resolution sizes of the PD patterns when training and testing the ANN with different PD dataset; (5 understanding the characteristics of multiple concurrent PD faults and effectively recognizing them; and (6 developing techniques in order to shorten the training time for the ANN as applied for PD recognition Finally, this paper critically assesses the suitability of ANNs for both online and offline PD detections outlining the advantages to the practitioners in the field. It is possible for the ANNs to determine the stage of degradation of the PD, thereby giving an indication of the seriousness of the fault.

  5. Partial Discharge Monitoring on Metal-Enclosed Switchgear with Distributed Non-Contact Sensors

    Directory of Open Access Journals (Sweden)

    Chongxing Zhang

    2018-02-01

    Full Text Available Metal-enclosed switchgear, which are widely used in the distribution of electrical energy, play an important role in power distribution networks. Their safe operation is directly related to the reliability of power system as well as the power quality on the consumer side. Partial discharge detection is an effective way to identify potential faults and can be utilized for insulation diagnosis of metal-enclosed switchgear. The transient earth voltage method, an effective non-intrusive method, has substantial engineering application value for estimating the insulation condition of switchgear. However, the practical application effectiveness of TEV detection is not satisfactory because of the lack of a TEV detection application method, i.e., a method with sufficient technical cognition and analysis. This paper proposes an innovative online PD detection system and a corresponding application strategy based on an intelligent feedback distributed TEV wireless sensor network, consisting of sensing, communication, and diagnosis layers. In the proposed system, the TEV signal or status data are wirelessly transmitted to the terminal following low-energy signal preprocessing and acquisition by TEV sensors. Then, a central server analyzes the correlation of the uploaded data and gives a fault warning level according to the quantity, trend, parallel analysis, and phase resolved partial discharge pattern recognition. In this way, a TEV detection system and strategy with distributed acquisition, unitized fault warning, and centralized diagnosis is realized. The proposed system has positive significance for reducing the fault rate of medium voltage switchgear and improving its operation and maintenance level.

  6. Partial Discharge Monitoring on Metal-Enclosed Switchgear with Distributed Non-Contact Sensors.

    Science.gov (United States)

    Zhang, Chongxing; Dong, Ming; Ren, Ming; Huang, Wenguang; Zhou, Jierui; Gao, Xuze; Albarracín, Ricardo

    2018-02-11

    Metal-enclosed switchgear, which are widely used in the distribution of electrical energy, play an important role in power distribution networks. Their safe operation is directly related to the reliability of power system as well as the power quality on the consumer side. Partial discharge detection is an effective way to identify potential faults and can be utilized for insulation diagnosis of metal-enclosed switchgear. The transient earth voltage method, an effective non-intrusive method, has substantial engineering application value for estimating the insulation condition of switchgear. However, the practical application effectiveness of TEV detection is not satisfactory because of the lack of a TEV detection application method, i.e., a method with sufficient technical cognition and analysis. This paper proposes an innovative online PD detection system and a corresponding application strategy based on an intelligent feedback distributed TEV wireless sensor network, consisting of sensing, communication, and diagnosis layers. In the proposed system, the TEV signal or status data are wirelessly transmitted to the terminal following low-energy signal preprocessing and acquisition by TEV sensors. Then, a central server analyzes the correlation of the uploaded data and gives a fault warning level according to the quantity, trend, parallel analysis, and phase resolved partial discharge pattern recognition. In this way, a TEV detection system and strategy with distributed acquisition, unitized fault warning, and centralized diagnosis is realized. The proposed system has positive significance for reducing the fault rate of medium voltage switchgear and improving its operation and maintenance level.

  7. Towards Optical Partial Discharge Detection with Micro Silicon Photomultipliers

    Directory of Open Access Journals (Sweden)

    Ming Ren

    2017-11-01

    Full Text Available Optical detection is reliable in intrinsically characterizing partial discharges (PDs. Because of the great volume and high-level power supply of the optical devices that can satisfy the requirements in photosensitivity, optical PD detection can merely be used in laboratory studies. To promote the practical application of the optical approach in an actual power apparatus, a silicon photomultiplier (SiPM-based PD sensor is introduced in this paper, and its basic properties, which include the sensitivity, pulse resolution, correlation with PD severity, and electromagnetic (EM interference immunity, are experimentally evaluated. The stochastic phase-resolved PD pattern (PRPD for three typical insulation defects are obtained by SiPM PD detector and are compared with those obtained using a high-frequency current transformer (HFCT and a vacuum photomultiplier tube (PMT. Because of its good performances in the above aspects and its additional advantages, such as the small size, low power supply, and low cost, SiPM offers great potential in practical optical PD monitoring.

  8. Partial discharge location technique for covered-conductor overhead distribution lines

    Energy Technology Data Exchange (ETDEWEB)

    Isa, M.

    2013-02-01

    In Finland, covered-conductor (CC) overhead lines are commonly used in medium voltage (MV) networks because the loads are widely distributed in the forested terrain. Such parts of the network are exposed to leaning trees which produce partial discharges (PDs) in CC lines. This thesis presents a technique to locate the PD source on CC overhead distribution line networks. The algorithm is developed and tested using a simulated study and experimental measurements. The Electromagnetic Transient Program-Alternative Transient Program (EMTP-ATP) is used to simulate and analyze a three-phase PD monitoring system, while MATLAB is used for post-processing of the high frequency signals which were measured. A Rogowski coil is used as the measuring sensor. A multi-end correlation-based technique for PD location is implemented using the theory of maximum correlation factor in order to find the time difference of arrival (TDOA) between signal arrivals at three synchronized measuring points. The three stages of signal analysis used are: (1) denoising by applying discrete wavelet transform (DWT); (2) extracting the PD features using the absolute or windowed standard deviation (STD) and; (3) locating the PD point. The advantage of this technique is the ability to locate the PD source without the need to know the first arrival time and the propagation velocity of the signals. In addition, the faulty section of the CC line between three measuring points can also be identified based on the degrees of correlation. An experimental analysis is performed to evaluate the PD measurement system performance for PD location on CC overhead lines. The measuring set-up is arranged in a high voltage (HV) laboratory. A multi-end measuring method is chosen as a technique to locate the PD source point on the line. A power transformer 110/20 kV was used to energize the AC voltage up to 11.5 kV/phase (20 kV system). The tests were designed to cover different conditions such as offline and online

  9. Fluid jet electric discharge source

    Science.gov (United States)

    Bender, Howard A [Ripon, CA

    2006-04-25

    A fluid jet or filament source and a pair of coaxial high voltage electrodes, in combination, comprise an electrical discharge system to produce radiation and, in particular, EUV radiation. The fluid jet source is composed of at least two serially connected reservoirs, a first reservoir into which a fluid, that can be either a liquid or a gas, can be fed at some pressure higher than atmospheric and a second reservoir maintained at a lower pressure than the first. The fluid is allowed to expand through an aperture into a high vacuum region between a pair of coaxial electrodes. This second expansion produces a narrow well-directed fluid jet whose size is dependent on the size and configuration of the apertures and the pressure used in the reservoir. At some time during the flow of the fluid filament, a high voltage pulse is applied to the electrodes to excite the fluid to form a plasma which provides the desired radiation; the wavelength of the radiation being determined by the composition of the fluid.

  10. Efficient method for location and detection of partial discharge in transformer oil by DOA estimation of circular array of ultrasonic sensors

    Science.gov (United States)

    Saravanakumar, N.; Sathiyasekar, K.

    2018-01-01

    The electrical insulation failures in oil transformers are mainly occurs due to the inappropriate placing of Partial Discharge (PD) sources. In order to eliminate the insulation defects and also to locate the PD sources in an appropriate location, a new approach called circular array of ultrasonic sensors (CAUS) with various analysis is proposed. At first de-noise the PD signal from the CAUS using the fast independent component analysis (Fast ICA) algorithm. Secondly, the wide band signal from CAUS is converted into narrow band signal by using the total least square algorithm (TLS). Third, parse representation of array covariance vector (SRACV) technique is utilized to separate DOA (Direction of Arrival) in three directions from PD to CAUS. Finally, the PD sources are placed in an appropriate location by using the pitch and azimuth angles of those three DOAs and the exact coordination of three planes are calculated by using the particle swarm optimization algorithm. The simulation result demonstrates the effectiveness of proposed approach in terms of PD location in transformer oil.

  11. Method and apparatus for debris mitigation for an electrical discharge source

    Science.gov (United States)

    Klebanoff, Leonard E [San Clemente, CA; Rader, Daniel J [Albuquerque, NM; Silfvast, William T [Helena, CA

    2006-01-24

    Method and apparatus for mitigating the transport of debris generated and dispersed from electric discharge sources by thermophoretic and electrostatic deposition. A member is positioned adjacent the front electrode of an electric discharge source and used to establish a temperature difference between it and the front electrode. By flowing a gas between the member and the front electrode a temperature gradient is established that can be used for thermophoretic deposition of particulate debris on either the member or front electrode depending upon the direction of the thermal gradient. Establishing an electric field between the member and front electrode can aid in particle deposition by electrostatic deposition.

  12. Metod And Apparatus For Debris Mitigation For An Electrical Discharge Source

    Science.gov (United States)

    Klebanoff, Leonard E.; Silfvast, William T.; Rader, Daniel J.

    2005-05-03

    Method and apparatus for mitigating the transport of debris generated and dispersed from electric discharge sources by thermophoretic and electrostatic deposition. A member is positioned adjacent the front electrode of an electric discharge source and used to establish a temperature difference between it and the front electrode. By flowing a gas between the member and the front electrode a temperature gradient is established that can be used for thermophoretic deposition of particulate debris on either the member or front electrode depending upon the direction of the thermal gradient. Establishing an electric field between the member and front electrode can aid in particle deposition by electrostatic deposition.

  13. Ion source using a hollow cathode discharge system and especially, particle accelerator comprising said source

    International Nuclear Information System (INIS)

    Mourier, Georges.

    1975-01-01

    An ion source provided with a hollow cathode discharge system is presented. The ion extraction system is designed in view of generating a beam directed towards a point of use located far from the point of ion production. Said source essentially comprises two cathodes facing each other, an anode at a continuous voltage with respect to the cathodes, a heated filament beyond the cathode on the path of the extracted beam, and a grid between said filament and cathode. The ion extraction is limited to a certain portion of the ions present inside the plasma, so as the discharge to continue to be sustained by itself. For that purpose pierced cathodes are used, with a transparency (the ratio of the hole area to the whole cathode area) not much higher than 50% [fr

  14. Source of high-voltage power supply for ozone generators at glow discharge

    International Nuclear Information System (INIS)

    Bruev, A.A.; Golota, V.I.; Zavada, L.M.; Taran, G.V.

    2000-01-01

    High-voltage power supply source on quasi-resonance inverter base which works at direct current regime is described. This source forms 20 kV voltage with 0 - 10 mA current regulation. It protects the source from current break-downs and feeds ozone generators at glow discharge

  15. Discharge physics and chemistry of a novel atmospheric pressure plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.; Henins, I.; Hermann, J.W.; Selwyn, G.S.; Jeong, J.Y.; Hickis, R.

    1999-07-01

    The atmospheric pressure plasma jet (APPJ) is a unique plasma source operating at atmospheric pressure. The APPJ operates with RF power and produces a stable non-thermal discharge in capacitively-coupled configuration. The discharge is spatially and temporally homogeneous and provides a unique gas phase chemistry that is well suited for various applications including etching, film deposition, surface treatment and decontamination of chemical and biological warfare (CBW) agents. A theoretical model shows electron densities of 0.2--2 x 10{sup 11} cm{sup {minus}3} for a helium discharge at a power level of 3--30 W cm{sup {minus}3}. The APPJ also produces a large flux, equivalent of up to 10,000 monolayer s{sup {minus}1}, of chemically-active, atomic and metastable molecular species which can impinge surfaces several cm downstream of the confined source. In addition, the efforts are in progress to measure the electron density using microwave diagnostics and to benchmark the gas phase chemical model by using LIF and titration.

  16. Optical pumping in a microfabricated Rb vapor cell using a microfabricated Rb discharge light source

    International Nuclear Information System (INIS)

    Venkatraman, V.; Kang, S.; Affolderbach, C.; Mileti, G.; Shea, H.

    2014-01-01

    Miniature ( 3 ) vapor-cell based devices using optical pumping of alkali atoms, such as atomic clocks and magnetometers, today mostly employ vertical-cavity surface-emitting lasers as pump light sources. Here, we report on the demonstration of optical pumping in a microfabricated alkali vapor resonance cell using (1) a microfabricated Rb discharge lamp light source, as well as (2) a conventional glass-blown Rb discharge lamp. The microfabricated Rb lamp cell is a dielectric barrier discharge (DBD) light source, having the same inner cell volume of around 40 mm 3 as that of the resonance cell, both filled with suitable buffer gases. A miniature (∼2 cm 3 volume) test setup based on the M z magnetometer interrogation technique was used for observation of optical-radiofrequency double-resonance signals, proving the suitability of the microfabricated discharge lamp to introduce efficient optical pumping. The pumping ability of this light source was found to be comparable to or even better than that of a conventional glass-blown lamp. The reported results indicate that the micro-fabricated DBD discharge lamp has a high potential for the development of a new class of miniature atomic clocks, magnetometers, and quantum sensors

  17. Ion source based on Penning discharge for production of doubly charged helium ions

    Directory of Open Access Journals (Sweden)

    V. I. Voznyi

    2017-11-01

    Full Text Available The article presents the results of operation of ion source with Penning discharge developed in the IAP of NAS of Ukraine to produce doubly charged helium ions He2+ beam and to increase the energy of accelerated ions up to 3.2 MeV. This energy is necessary for ERDA channel when measuring hydrogen concentration in the structural materials used in nuclear engineering. The ion source parameters are the following: discharge voltage is 6 kV, discharge current is 0.8 - 1.2 mA, the current of singly charged helium ions He+ 24 μA, the current of doubly charged helium ions He2+ 0.5 μA.

  18. A Compact Source of Flash-Corona Discharge for Biomedical Applications

    Science.gov (United States)

    Moshkunov, S. I.; Khomich, V. Yu.; Shershunova, E. A.

    2018-01-01

    A compact source of low-temperature plasma for biological and medical applications is proposed, which operates at kilohertz frequencies in the regime of flash-corona discharge with an energy of 0.1 mJ/pulse. The plasma source was tested in application to plasma pretreatment of green salad seeds. Plasma-treated seeds exhibited increased (by about 25%) germination speed as compared to that in the untreated control.

  19. Beam-plasma discharge in a Kyoto beam-plasma-ion source

    International Nuclear Information System (INIS)

    Ishikawa, J.; Takagi, T.

    1983-01-01

    A beam-plasma type ion source employing an original operating principle has been developed by the present authors. The ion source consists of an ion extraction region with an electron gun, a thin long drift tube as the plasma production chamber, and a primary electron beam collector. An electron beam is effectively utilized for the dual purpose of high density plasma production as a result of beam-plasma discharge, and high current ion beam extraction with ion space-charge compensation. A high density plasma of the order of 10 11 --10 13 cm -3 was produced by virtue of the beam-plasma discharge which was caused by the interaction between a space-charge wave on the electron beam and a high frequency plasma wave. The plasma density then produced was 10 2 --10 3 times the density produced only by collisional ionization by the electron beam. In order to obtain a stable beam-plasma discharge, a secondary electron beam emitted from the electron collector should be utilized. The mechanism of the beam-plasma discharge was analyzed by use of a linear theory in the case of the small thermal energy of the electron beam, and by use of a quasilinear theory in the case of the large thermal energy. High current ion beams of more than 0.1 A were extracted even at a low extraction voltage of 1--5 kV

  20. Study on a negative hydrogen ion source with hot cathode arc discharge.

    Science.gov (United States)

    Lin, S H; Fang, X; Zhang, H J; Qian, C; Ma, B H; Wang, H; Li, X X; Zhang, X Z; Sun, L T; Zhang, Z M; Yuan, P; Zhao, H W

    2014-02-01

    A negative hydrogen (H(-)) ion source with hot cathode arc discharge was designed and fabricated as a primary injector for a 10 MeV PET cyclotron at IMP. 1 mA dc H(-) beam with ɛ N, RMS = 0.08 π mm mrad was extracted at 25 kV. Halbach hexapole was adopted to confine the plasma. The state of arc discharge, the parameters including filament current, arc current, gas pressure, plasma electrode bias, and the ratio of I(e(-))/I(H(-)) were experimentally studied. The discussion on the result, and opinions to improve the source were given.

  1. A lower dimensional feature vector for identification of partial discharges of different origin using time measurements

    International Nuclear Information System (INIS)

    Evagorou, Demetres; Kyprianou, Andreas; Georghiou, George E; Lewin, Paul L; Stavrou, Andreas

    2012-01-01

    Partial discharge (PD) classification into sources of different origin is essential in evaluating the severity of the damage caused by its activity on the insulation of power cables and their accessories. More specifically, some types of PD can be classified as having a detrimental effect on the integrity of the insulation while others can be deemed relatively harmless, rendering the correct classification of different PD types of vital importance to electrical utilities. In this work, a feature vector was proposed based on higher order statistics on selected nodes of the wavelet packet transform (WPT) coefficients of time domain measurements, which can compactly represent the characteristics of different PD sources. To assess its performance, experimental data acquired under laboratory conditions for four different PD sources encountered in power systems were used. The two learning machine methods, namely the support vector machine and the probabilistic neural network, employed as the classification algorithms, achieved overall classification rates of around 98%. In comparison, the utilization of the scaled, raw WPT coefficients as a feature vector resulted in classification accuracy of around 99%, but with a significantly higher number of dimensions (1304 to 16), validating the PD identification ability of the proposed feature. Dimensionality reduction becomes a key factor in online, real-time data collection and processing of PD measurements, reducing the classification effort and the data-storage requirements. Therefore, the proposed method can constitute a potential tool for such online measurements, after addressing issues related to on-site measurements such as the rejection of interference. (paper)

  2. Light and Light Sources High-Intensity Discharge Lamps

    CERN Document Server

    Flesch, Peter G

    2006-01-01

    Light and Light Sources gives an introduction to the working principles of high-intensity discharge (HID) lamps and points out challenges and problems associated with the development and operation of HID lamps. The state-of-the-art in electrode and plasma diagnostics as well as numerical methods used for the understanding of HID lamps are described. This volume addresses students as well as scientists and researchers at universities and in industry.

  3. Optical pumping in a microfabricated Rb vapor cell using a microfabricated Rb discharge light source

    Energy Technology Data Exchange (ETDEWEB)

    Venkatraman, V.; Kang, S.; Affolderbach, C.; Mileti, G., E-mail: gaetano.mileti@unine.ch [Laboratoire Temps-Fréquence, University of Neuchâtel, Neuchâtel 2000 (Switzerland); Shea, H. [Microsystems for Space Technologies Laboratory, Ecole Polytechnique Fédérale de Lausanne (EPFL), Neuchâtel 2002 (Switzerland)

    2014-02-03

    Miniature (sources. Here, we report on the demonstration of optical pumping in a microfabricated alkali vapor resonance cell using (1) a microfabricated Rb discharge lamp light source, as well as (2) a conventional glass-blown Rb discharge lamp. The microfabricated Rb lamp cell is a dielectric barrier discharge (DBD) light source, having the same inner cell volume of around 40 mm{sup 3} as that of the resonance cell, both filled with suitable buffer gases. A miniature (∼2 cm{sup 3} volume) test setup based on the M{sub z} magnetometer interrogation technique was used for observation of optical-radiofrequency double-resonance signals, proving the suitability of the microfabricated discharge lamp to introduce efficient optical pumping. The pumping ability of this light source was found to be comparable to or even better than that of a conventional glass-blown lamp. The reported results indicate that the micro-fabricated DBD discharge lamp has a high potential for the development of a new class of miniature atomic clocks, magnetometers, and quantum sensors.

  4. On the Feasibility of Gap Detection of Power Transformer Partial Discharge UHF Signals: Gap Propagation Characteristics of Electromagnetic Waves

    Directory of Open Access Journals (Sweden)

    Xiaoxing Zhang

    2017-10-01

    Full Text Available This study analyzed the transformer electromagnetic gap propagation characteristics. The influence of gap size is also analyzed, and the results experimentally verified. The obtained results indicated that the gap propagation characteristics of electromagnetic wave signals radiated by the partial discharge (PD source in different directions are substantially different. The intensity of the electromagnetic wave in the gap reaches a maximum at a gap height of 1 cm; and inside the gap, the intensity of the electromagnetic wave depicted an increasing trend at the tail area of the gap. Finally, from the obtained results, some suggestions on where to install sensors in practical systems for ultra high frequency (UHF PD signal detection in the transformer gap are provided. The obtained results confirmed the feasibility of using this approach. These results can be seen as a benchmark and a challenge for further research in this field.

  5. Interpretation of duoplasmatron-type ion sources from a model of the discharge

    International Nuclear Information System (INIS)

    Lejeune, C.

    1971-06-01

    The performance logical improvement of these sources needs a precise knowledge of the emitting ionized medium, on which the whole of the properties is depending. Ion production mechanisms have been studied in the discharge together with their transport towards the extraction hole. The source properties are described, in a new manner, as a function of the discharge modes. The discharge is characterized by the existence of a mode change, related to anode column neutral atom lowering in anode column (arc starvation). The complementarity of probe measurements and the energy spectra analysis of the charges emitted by the anode hole allowed to get the potential axial profile, to discover an electric energetic electron beam extracted from cathodic plasma by the striction shealth potential difference and to determine the electron density radial profile in the anode column. Result analysis allows to get a simple scheme of plasmas and laws controlling them in each of the important modes. The density and potential axial theoretical repartition has been calculated as a function of independent parameters-anode pressure and arc intensity and of three secondary parameters characterizing the energy exchange (electron temperature) and magnetic field topography. The agreement between model predictions and experimental variations for source properties -more specifically gas nature and geometry- allow to give the duoplasmatrons sources similitude rules. The discharge model has allowed to interpret the luminous emission spectra from the anode column. It has been shown theoretically that the peculiar conditions of ionization and excitation allow to use the column as an amplifier medium in the optically field. This plasma has been used successfully as an active medium for an ionic laser in a continuous mode [fr

  6. The nature and source of irregular discharges to stormwater entering Sydney estuary, Australia

    International Nuclear Information System (INIS)

    Beck, H.J.; Birch, G.F.

    2014-01-01

    Irregular discharges of polluted stormwater into drainage systems during base flow (no rainfall) result in acute ecological impacts within fluvial and estuarine environments. In this study, metal and TSS concentrations were significantly more variable during business hours of weekdays (i.e. high-business activity) than weekends/public holidays (i.e. low-business activity) within three highly-urbanised catchments of Sydney estuary (Australia), as determined by analysing multivariate dispersion (PERMDISP). Concentrations of TSS and all metals analysed (Al, Ca, Cu, Fe, Mg, Pb and Zn) were also significantly greater during high- than low-business periods within at least one of the three catchments. In no case were concentrations significantly higher during low- than high-business periods. This pattern of contamination supports the hypothesis that commercial and industrial sources are major contributors of irregular discharges of contamination to Sydney estuary. Irregular discharges and consequential ecological impacts may be effectively reduced in this environment by focussing management efforts on these activities. - Highlights: • Irregular discharges of pollution have acute impacts on aquatic ecosystems. • These discharges were thought to be made during low activity periods, such as night. • Pollution was more concentrated and erratic during high- than low-business periods. • Timing of pollution suggests commercial and industrial activities are major sources. • Discharges effectively reduced by managing commercial and industrial activities. - Previously unreported irregular, illegal discharges of polluted stormwater released to estuaries result in acute ecological impacts and are potentially related to commercial/industrial activities

  7. Fundamental aspects of excitation and propagation of on-line partial discharge signals in three-phase medium voltage cable systems

    NARCIS (Netherlands)

    Wielen, van der P.C.J.M.; Steennis, E.F.; Wouters, P.A.A.F.

    2003-01-01

    On-line partial discharge (PD) detection of three-phase belted medium voltage cable connections results in a number of interpretation differences as compared to off-line measurements where only one phase is energized. The induced currents and charges in the phase conductors and earth screen upon a

  8. Power source for inactivation of micro-organisms with partial high voltage discharge in a continuous process

    NARCIS (Netherlands)

    Creyghton, Y.; Beurskens, R.; Fiala, A.; Haan, S.W.H. de

    2002-01-01

    An electrical discharge technology is investigated as non-thermal method for inactivation of microorganisms. Potential applications include treatment of drinking water (e.g. legionella) and liquid food pasteurization (e.g. fruit juices). A strong interest exists in mild food conservation processes

  9. Characteristics of Partial Discharge and Ozone Generation for Twisted-pair of Enameled Wires under High-repetitive Impulse Voltage Application

    Science.gov (United States)

    Kanazawa, Seiji; Enokizono, Masato; Shibakita, Toshihide; Umehara, Eiji; Toshimitsu, Jun; Ninomiya, Shinji; Taniguchi, Hideki; Abe, Yukari

    In recent years, inverter drive machines such as a hybrid vehicle and an electric vehicle are operated under high voltage pulse with high repetition rate. In this case, inverter surge is generated and affected the machine operation. Especially, the enameled wire of a motor is deteriorated due to the partial discharge (PD) and finally breakdown of the wire will occur. In order to investigate a PD on a resistant enameled wire, characteristics of PD in the twisted pair sample under bipolar repetitive impulse voltages are investigated experimentally. The relationship between the applied voltage and discharge current was measured at PD inception and extinction, and we estimated the repetitive PD inception and extinction voltages experimentally. The corresponding optical emission of the discharge was also observed by using an ICCD camera. Furthermore, ozone concentration due to the discharge was measured during the life-time test of the resistant enameled wires from a working environmental point of view.

  10. Partially hydrolyzed guar gum as a potential prebiotic source.

    Science.gov (United States)

    Mudgil, Deepak; Barak, Sheweta; Patel, Ami; Shah, Nihir

    2018-06-01

    Guar galactomannan was enzymatically hydrolyzed to obtain partially hydrolyzed guar gum which can be utilized as prebiotic source. In present study, growth of probiotics (Lactic Acid Bacteria strains) were studied with glucose, partially hydrolyzed guar gum and native guar gum. All the six strains were galactose &/or mannose positive using the API CHl 50 test. Almost all these strains showed an ability to assimilate partially hydrolyzed guar gum with respect to increase in optical density and viable cell count with concomitant decrease in the pH of the growth medium. Streptococcus thermophilus MD2 exhibited higher growth (7.78 log cfu/ml) while P. parvulus AI1 showed comparatively less growth (7.24 log cfu/ml) as compared to used lactobacillus and Weissella strains. Outcomes of the current study suggest that partially hydrolyzed guar can be considered as potential prebiotic compound that may further stimulate the growth of potentially probiotic bacteria or native gut microflora. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Neutralization of an ion beam from the end-Hall ion source by a plasma electron source based on a discharge in crossed E × H fields

    Science.gov (United States)

    Dostanko, A. P.; Golosov, D. A.

    2009-10-01

    The possibility of using a plasma electron source (PES) with a discharge in crossed E × H field for compensating the ion beam from an end-Hall ion source (EHIS) is analyzed. The PES used as a neutralizer is mounted in the immediate vicinity of the EHIS ion generation and acceleration region at 90° to the source axis. The behavior of the discharge and emission parameters of the EHIS is determined for operation with a filament neutralizer and a plasma electron source. It is found that the maximal discharge current from the ion source attains a value of 3.8 A for operation with a PES and 4 A for operation with a filament compensator. It is established that the maximal discharge current for the ion source strongly depends on the working gas flow rate for low flow rates (up to 10 ml/min) in the EHIS; for higher flow rates, the maximum discharge current in the EHIS depends only on the emissivity of the PES. Analysis of the emission parameters of EHISs with filament and plasma neutralizers shows that the ion beam current and the ion current density distribution profile are independent of the type of the electron source and the ion current density can be as high as 0.2 mA/cm2 at a distance of 25 cm from the EHIS anode. The balance of currents in the ion source-electron source system is considered on the basis of analysis of operation of EHISs with various sources of electrons. It is concluded that the neutralization current required for operation of an ion source in the discharge compensation mode must be equal to or larger than the discharge current of the ion source. The use of PES for compensating the ion beam from an end-Hall ion source proved to be effective in processes of ion-assisted deposition of thin films using reactive gases like O2 or N2. The application of the PES technique makes it possible to increase the lifetime of the ion-assisted deposition system by an order of magnitude (the lifetime with a Ti cathode is at least 60 h and is limited by the

  12. Discharging a DC bus capacitor of an electrical converter system

    Science.gov (United States)

    Kajouke, Lateef A; Perisic, Milun; Ransom, Ray M

    2014-10-14

    A system and method of discharging a bus capacitor of a bidirectional matrix converter of a vehicle are presented here. The method begins by electrically shorting the AC interface of the converter after an AC energy source is disconnected from the AC interface. The method continues by arranging a plurality of switching elements of a second energy conversion module into a discharge configuration to establish an electrical current path from a first terminal of an isolation module, through an inductive element, and to a second terminal of the isolation module. The method also modulates a plurality of switching elements of a first energy conversion module, while maintaining the discharge configuration of the second energy conversion module, to at least partially discharge a DC bus capacitor.

  13. Initial operation of the CW 8X H- ion source discharge

    International Nuclear Information System (INIS)

    Smith, H.V. Jr.; Allison, P.; Geisik, C.; Schmitt, D.R.; Schneider, J.D.; Stelzer, J.E.

    1993-01-01

    A pulsed 8Χ source was built and the H - beam current, emittance, and power efficiency were measured. These results were promising, so a cooled, dc version designed for operation at arc power levels up to 30 kW was built. Testing of the CW 8Χ source discharge is underway. The design dc power loading on the cathode surface is 900 W/cm 2 , considerably higher than achieved in any pervious Penning surface-plasma source (SPS). Thus, the electrode surfaces are cooled with pressurized, hot water. We describe the source and present the initial operating experience and arc test results

  14. Initial operation of the CW 8X H- ion source discharge

    International Nuclear Information System (INIS)

    Smith, H.V. Jr.; Allison, P.; Geisik, C.; Schmitt, D.R.; Schneider, J.D.; Stelzer, J.E.

    1993-01-01

    A pulsed 8X source was built and the H - beam current, emittance, and power efficiency were measured. These results were promising, so a cooled, dc version designed for operation at arc power levels up to 30 kW was built. Testing of the CW 8X source discharge is underway. The design dc power loading on the cathode surface is 900 W/cm 2 , considerably higher than achieved in any previous Penning surface-plasma source (SPS). Thus, the electrode surfaces are cooled with pressurized, hot water. The authors describe the source and present the initial operating experience and arc test results

  15. Development of high efficiency Versatile Arc Discharge Ion Source at CERN ISOLDE.

    Science.gov (United States)

    Penescu, L; Catherall, R; Lettry, J; Stora, T

    2010-02-01

    We report here recent developments of Forced Electron Beam Induced Arc Discharge (FEBIAD) ion sources at the ISOLDE radioactive ion beam facility, hosted at the European Organization for Nuclear Research (CERN). As a result of the propositions to improve the ionization efficiency, two FEBIAD prototypes have been produced and successfully tested in 2008. Off-line studies showed that the 1+ ionization efficiencies for noble gases are 5-20 times larger than with the standard ISOLDE FEBIAD ion sources and reach 60% for radon, which allowed the identification at ISOLDE of (229)Rn, an isotope that had never previously been observed in the laboratory. A factor of 3 increase is also expected for the ionization efficiency of the other elements. The experimental and theoretical methodology is presented. The theoretical model, which gives precise insights on the processes affecting the ionization, is used to design optimal sources (grouped under the name of VADIS--Versatile Arc Discharge Ion Source) for the different chemical classes of the produced isotopes, as already demonstrated for the noble gases.

  16. New type of discharge-produced plasma source for extreme ultraviolet based on liquid tin jet electrodes

    NARCIS (Netherlands)

    Koshelev, K.N.; Krivtsun, V.M.; Ivanov, V.; Yakushev, O.; Chekmarev, A.; Koloshnikov, V.; Snegirev, E.; Medvedev, Viacheslav

    2012-01-01

    A new approach for discharge-produced plasma (DPP) extreme ultraviolet (EUV) sources based on the usage of two liquid metallic alloy jets as discharge electrodes has been proposed and tested. Discharge was ignited using laser ablation of one of the cathode jets. A system with two jet electrodes was

  17. Using Soluble Reactive Phosphorus and Ammonia to Identify Point Source Discharge from Large Livestock Facilities

    Science.gov (United States)

    Borrello, M. C.; Scribner, M.; Chessin, K.

    2013-12-01

    A growing body of research draws attention to the negative environmental impacts on surface water from large livestock facilities. These impacts are mostly in the form of excessive nutrient loading resulting in significantly decreased oxygen levels. Over-application of animal waste on fields as well as direct discharge into surface water from facilities themselves has been identified as the main contributor to the development of hypoxic zones in Lake Erie, Chesapeake Bay and the Gulf of Mexico. Some regulators claim enforcement of water quality laws is problematic because of the nature and pervasiveness of non-point source impacts. Any direct discharge by a facility is a violation of permits governed by the Clean Water Act, unless the facility has special dispensation for discharge. Previous research by the principal author and others has shown runoff and underdrain transport are the main mechanisms by which nutrients enter surface water. This study utilized previous work to determine if the effects of non-point source discharge can be distinguished from direct (point-source) discharge using simple nutrient analysis and dissolved oxygen (DO) parameters. Nutrient and DO parameters were measured from three sites: 1. A stream adjacent to a field receiving manure, upstream of a large livestock facility with a history of direct discharge, 2. The same stream downstream of the facility and 3. A stream in an area relatively unimpacted by large-scale agriculture (control site). Results show that calculating a simple Pearson correlation coefficient (r) of soluble reactive phosphorus (SRP) and ammonia over time as well as temperature and DO, distinguishes non-point source from point source discharge into surface water. The r value for SRP and ammonia for the upstream site was 0.01 while the r value for the downstream site was 0.92. The control site had an r value of 0.20. Likewise, r values were calculated on temperature and DO for each site. High negative correlations

  18. [Characteristics and loads of key sources of pollutions discharged into Beishi River, Changzhou City].

    Science.gov (United States)

    Li, Chun-Ping; Jiang, Jian-Guo; Chen, Ai-Mei; Wu, Jia-Ling; Fan, Xiu-Juan; Ye, Bin

    2010-11-01

    Choosing the Beishi river, Changzhou City as the study area, the sewage generation, pollutants characteristics and sewage discharge in catchment area of Beishi river were conducted, detailed investigated and monitored. After using pollution coefficients, the yearly loads of all sources of pollutions were calculated to determine the highest sewage. The results showed that: except pH, the high concentration of SS, COD, BOD5, ammonia nitrogen, TN and TP discharged from MSW collecting houses, MSW transfer stations, public toilets and dining in Changzhou city far exceeded the "Integrated Wastewater Discharge Standard" (GB 8978-1996) and "Effluent Discharged into the City Sewer Water Quality Standards" (CJ 3082-1999). Among which: the highest concentration of COD discharged from MSW transfer stations was up to 51 700 mg/L, while the ammonia nitrogen and TN were as high as 1 616 mg/L and 2 044 mg/L in the toilet wastewater. In addition to this, the ratio of wastewater discharged directly into the river through storm water pipe network was higher from MSW houses, MSW transfer stations, public toilets, dining and other waste in Changzhou city. The 125.2 t/a of COD and 40.53 t/a of BOD5 were the two highest concentrations of various sources of pollution. The highest annual polluting loads discharged into Beishi river is dining, followed by the sanitation facilities. Therefore, cutting pollution control of food and sanitation facilities along the river is particularly urgent.

  19. Argon discharge characteristics in cold cathode penning ion source. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Abd El-Baki, M M; Abd El-Rahman, M M; Basal, N I [Ion Sources and Accelerators Department, Nuclear Research Center, Atomic energy Authority, Cairo, (Egypt)

    1996-03-01

    This study includes the production of argon discharge inside cold cathode penning ion source with axial d.c. extraction. The arc characteristics are investigated under the influence of the discharge parameters such as the pressure, axial magnetic field. At zero magnetic field and pressure 4.2 x 10{sup -4} torr, the arc voltage which is needed for arc initiation is relatively large V{sub arc} = 430 V, and I{sub arc} = 0.3 A. The application of the magnetic field helps the appearance of argon arc at lower voltage, e.g. at I{sub B} = 0.8 A, the arc voltage V{sub arc} = 320 V, and I{sub arc} = 0.3 A. It is found that the arc current increase with the increase of pressure, i.e. the increase of gas flow inside the source, while the arc voltage decreases. 7 fig.

  20. Organic impurities harmful to arc discharge in multi-ampere duo-pigatron ion source

    International Nuclear Information System (INIS)

    Peng Zhudong; Wang Shouhu; Chen Miaosun; Huang Chongan; Ge Yishan; Fu Peng; E Maohuai

    1989-01-01

    Besides mechanism producing plasmain Duo-Pigatron Ion Source, the main purpose of this paper is to introduce the problem on arc discharge exhaustion caused by oil pollution. The problem was discovered during developing a 15 cm Duo-Pigatron Ion Source. The paper also describes its physical process

  1. Electrode configuration for extreme-UV electrical discharge source

    Science.gov (United States)

    Spence, Paul Andrew; Fornaciari, Neal Robert; Chang, Jim Jihchyun

    2002-01-01

    It has been demonstrated that debris generation within an electric capillary discharge source, for generating extreme ultraviolet and soft x-ray, is dependent on the magnitude and profile of the electric field that is established along the surfaces of the electrodes. An electrode shape that results in uniform electric field strength along its surface has been developed to minimize sputtering and debris generation. The electric discharge plasma source includes: (a) a body that defines a circular capillary bore that has a proximal end and a distal end; (b) a back electrode positioned around and adjacent to the distal end of the capillary bore wherein the back electrode has a channel that is in communication with the distal end and that is defined by a non-uniform inner surface which exhibits a first region which is convex, a second region which is concave, and a third region which is convex wherein the regions are viewed outwardly from the inner surface of the channel that is adjacent the distal end of the capillary bore so that the first region is closest to the distal end; (c) a front electrode positioned around and adjacent to the proximal end of the capillary bore wherein the front electrode has an opening that is communication with the proximal end and that is defined by a non-uniform inner surface which exhibits a first region which is convex, a second region which is substantially linear, and third region which is convex wherein the regions are viewed outwardly from the inner surface of the opening that is adjacent the proximal end of the capillary bore so that the first region is closest to the proximal end; and (d) a source of electric potential that is connected across the front and back electrodes.

  2. Ionized-cluster source based on high-pressure corona discharge

    International Nuclear Information System (INIS)

    Lokuliyanage, K.; Huber, D.; Zappa, F.; Scheier, P.

    2006-01-01

    Full text: It has been demonstrated that energetic beams of large clusters, with thousands of atoms, can be a powerful tool for surface modification. Normally ionized cluster beams are obtained by electron impact on neutral beams produced in a supersonic expansion. At the University of Innsbruck we are pursuing the realization of a high current cluster ion source based on the corona discharge.The idea in the present case is that the ionization should occur prior to the supersonic expansion, thus supersede the need of subsequent electron impact. In this contribution we present the project of our source in its initial stage. The intensity distribution of cluster sizes as a function of the source parameters, such as input pressure, temperature and gap voltage, are investigated with the aid of a custom-built time of flight mass spectrometer. (author)

  3. The source, discharge, and chemical characteristics of water from Agua Caliente Spring, Palm Springs, California

    Science.gov (United States)

    Contributors: Brandt, Justin; Catchings, Rufus D.; Christensen, Allen H.; Flint, Alan L.; Gandhok, Gini; Goldman, Mark R.; Halford, Keith J.; Langenheim, V.E.; Martin, Peter; Rymer, Michael J.; Schroeder, Roy A.; Smith, Gregory A.; Sneed, Michelle; Martin, Peter

    2011-01-01

    Agua Caliente Spring, in downtown Palm Springs, California, has been used for recreation and medicinal therapy for hundreds of years and currently (2008) is the source of hot water for the Spa Resort owned by the Agua Caliente Band of the Cahuilla Indians. The Agua Caliente Spring is located about 1,500 feet east of the eastern front of the San Jacinto Mountains on the southeast-sloping alluvial plain of the Coachella Valley. The objectives of this study were to (1) define the geologic structure associated with the Agua Caliente Spring; (2) define the source(s), and possibly the age(s), of water discharged by the spring; (3) ascertain the seasonal and longer-term variability of the natural discharge, water temperature, and chemical characteristics of the spring water; (4) evaluate whether water-level declines in the regional aquifer will influence the temperature of the spring discharge; and, (5) estimate the quantity of spring water that leaks out of the water-collector tank at the spring orifice.

  4. Partial coherence and imperfect optics at a synchrotron radiation source modeled by wavefront propagation

    Science.gov (United States)

    Laundy, David; Alcock, Simon G.; Alianelli, Lucia; Sutter, John P.; Sawhney, Kawal J. S.; Chubar, Oleg

    2014-09-01

    A full wave propagation of X-rays from source to sample at a storage ring beamline requires simulation of the electron beam source and optical elements in the beamline. The finite emittance source causes the appearance of partial coherence in the wave field. Consequently, the wavefront cannot be treated exactly with fully coherent wave propagation or fully incoherent ray tracing. We have used the wavefront code Synchrotron Radiation Workshop (SRW) to perform partially coherent wavefront propagation using a parallel computing cluster at the Diamond Light Source. Measured mirror profiles have been used to correct the wavefront for surface errors.

  5. Microplasma discharge vacuum ultraviolet photoionization source for atmospheric pressure ionization mass spectrometry.

    Science.gov (United States)

    Symonds, Joshua M; Gann, Reuben N; Fernández, Facundo M; Orlando, Thomas M

    2014-09-01

    In this paper, we demonstrate the first use of an atmospheric pressure microplasma-based vacuum ultraviolet (VUV) photoionization source in atmospheric pressure mass spectrometry applications. The device is a robust, easy-to-operate microhollow cathode discharge (MHCD) that enables generation of VUV photons from Ne and Ne/H(2) gas mixtures. Photons were detected by excitation of a microchannel plate detector and by analysis of diagnostic sample ions using a mass spectrometer. Reactive ions, charged particles, and metastables produced in the discharge were blocked from entering the ionization region by means of a lithium fluoride window, and photoionization was performed in a nitrogen-purged environment. By reducing the output pressure of the MHCD, we observed heightened production of higher-energy photons, making the photoionization source more effective. The initial performance of the MHCD VUV source has been evaluated by ionizing model analytes such as acetone, azulene, benzene, dimethylaniline, and glycine, which were introduced in solid or liquid phase. These molecules represent species with both high and low proton affinities, and ionization energies ranging from 7.12 to 9.7 eV.

  6. Radio frequency glow discharge source with integrated voltage and current probes used for evaluation of discharge parameters

    International Nuclear Information System (INIS)

    Wilken, L.; Hoffmann, V.; Wetzig, K.

    2006-01-01

    A radio frequency (rf) Grimm-type glow discharge source for the chemical analysis of solid samples, with integrated voltage and current probes, was developed. All elements of a plasma equivalent circuit are determined from the measured current-voltage characteristics. The procedure is based on the independent evaluation of the ion current and electron current region. The physical meaning of the parameters is investigated by comparisons with measurements from dc glow discharges. We found that the reduced rf current of the powered electrode is comparable to the reduced current in dc discharges. A formula is developed that corrects the reduced current due to gas heating. The sheath thickness at the powered rf electrode is evaluated and is between 75 and 1100 μm. The voltage of the bulk plasma is in the range 2-15 V, and the resistance is between 30 and 400 Ω. The bulk plasma consumes about 3% of the total power, and the reduced voltage is comparable to the reduced electrical field in the positive column of direct current discharges. The sheath voltage at the grounded electrode is in the range 25-100 V, the capacities are between 10 and 400 pF, and the resistances are in the range 100 Ω-5000 Ω. We also found invariants for the evaluated sheath parameters

  7. V-I curves and plasma parameters in a high density DC glow discharge generated by a current-source

    International Nuclear Information System (INIS)

    Granda-Gutierrez, E E; Lopez-Callejas, R; Piedad-Beneitez, A de la; BenItez-Read, J S; Pacheco-Sotelo, J O; Pena-Eguiluz, R; A, R Valencia; Mercado-Cabrera, A; Barocio, S R

    2008-01-01

    Nitrogen DC glow discharges, conducted in a cylindrical geometry, have been characterized using a new current-source able to provide 10 -3 - 3 A for the sustainment of the discharge, instead of a conventional voltage-source. The V-I characteristic curves obtained from these discharges were found to fit the general form i(v) = A(p)v k(p) , whereby the plasma itself can be modeled as a voltage-controlled current-source. We conclude that the fitting parameters A and k, which mainly depend on the gas pressure p, are strongly related to the plasma characteristics, so much so that they can indicate the pressure interval in which the maximum plasma density is located, with values in the order of 10 16 m -3 at reduced discharge potential (300-600 V) and low working pressure (10 -1 - 10 1 Pa)

  8. Glow discharging device

    International Nuclear Information System (INIS)

    Maeno, Katsuki; Kawasaki, Kozo; Hiratsuka, Hajime; Kawashima, Shuichi.

    1989-01-01

    In a thermonuclear device, etc. impurities adsorbed to inner walls of a vacuum vessel by glow discharge are released to clean the vacuum vessel for preventing intrusion of the impurities into plasmas. The object of the present invention is to minimize the capacity of a power source equipment for the glow discharge device to the least extent. That is, a stabilization resistance is connected in series between each of a plurality of anodes which are inserted and arranged at the inside of a vacuum vessel as a cathode and a power source respectively. The resistance value R is selected so as to satisfy the relation: R < (Vi - Vm)/Ii, in which Vi: glow discharge starting voltage, Vm: glow discharge keeping voltage, Ii: glow discharge starting current. Accordingly, if a voltage is applied from a power source to a plurality of anodes, scattering of electric discharge between the anodes can be suppressed and the effect of voltage drop during discharge by the stabilization resistance can be eliminated. As a result, it is possible to provide an economically advantageous glow discharge device with the capacity for the power source facility being to the least extent. (K.M.)

  9. Numerical simulation of atmospheric-pressure helium discharge driven by combined radio frequency and trapezoidal pulse sources

    International Nuclear Information System (INIS)

    Wang Qi; Sun Jizhong; Zhang Jianhong; Ding Zhenfeng; Wang Dezhen

    2010-01-01

    Atmospheric-pressure capacitive discharges driven by combined radio frequency (rf) and trapezoidal pulse sources are investigated using a one-dimensional self-consistent fluid model. The results show that the plasma intensity in the rf discharge can be enhanced drastically when a low duty ratio short pulse source is additionally applied. The mechanism for the increase in the plasma density can be attributed to a strong localized electric field induced by the applied short pulse; the strong electric field generates a great number of high energy electrons and chemically active particles, which subsequently generate more electrons and ions. The rf capacitive discharges with the aid of externally applied short pulses can achieve a high plasma density with better power efficiency.

  10. Rebound of a coal tar creosote plume following partial source zone treatment with permanganate.

    Science.gov (United States)

    Thomson, N R; Fraser, M J; Lamarche, C; Barker, J F; Forsey, S P

    2008-11-14

    The long-term management of dissolved plumes originating from a coal tar creosote source is a technical challenge. For some sites stabilization of the source may be the best practical solution to decrease the contaminant mass loading to the plume and associated off-site migration. At the bench-scale, the deposition of manganese oxides, a permanganate reaction byproduct, has been shown to cause pore plugging and the formation of a manganese oxide layer adjacent to the non-aqueous phase liquid creosote which reduces post-treatment mass transfer and hence mass loading from the source. The objective of this study was to investigate the potential of partial permanganate treatment to reduce the ability of a coal tar creosote source zone to generate a multi-component plume at the pilot-scale over both the short-term (weeks to months) and the long-term (years) at a site where there is >10 years of comprehensive synoptic plume baseline data available. A series of preliminary bench-scale experiments were conducted to support this pilot-scale investigation. The results from the bench-scale experiments indicated that if sufficient mass removal of the reactive compounds is achieved then the effective solubility, aqueous concentration and rate of mass removal of the more abundant non-reactive coal tar creosote compounds such as biphenyl and dibenzofuran can be increased. Manganese oxide formation and deposition caused an order-of-magnitude decrease in hydraulic conductivity. Approximately 125 kg of permanganate were delivered into the pilot-scale source zone over 35 days, and based on mass balance estimates 35% reduction for all monitored compounds except for biphenyl, dibenzofuran and fluoranthene 150 days after treatment, which is consistent with the bench-scale experimental results. Pre- and post-treatment soil core data indicated a highly variable and random spatial distribution of mass within the source zone and provided no insight into the mass removed of any of the

  11. Carbon source from the toroidal pumped limiter during long discharge operation in Tore Supra

    International Nuclear Information System (INIS)

    Dufour, E.; Brosset, C.; Lowry, C.; Bucalossi, J.; Chappuis, P.; Corre, Y.; Desgranges, C.; Guirlet, R.; Gunn, J.; Loarer, T.; Mitteau, R.; Monier-Garbet, P.; Pegourie, B.; Reichle, R.; Thomas, P.; Tsitrone, E.; Hogan, J.; Roubin, P.; Martin, C.; Arnas, C.

    2005-01-01

    A better understanding of deuterium retention mechanisms requires the knowledge of carbon sources in Tore-Supra. The main source of carbon in the vacuum vessel during long discharges is the toroidal pumped limiter (TPL). This work is devoted to the experimental characterisation of the carbon source from the TPL surface during long discharges using a visible spectroscopy diagnostic. Moreover, we present an attempt to perform a carbon balance over a typical campaign and we discuss it with regards to the deuterium in-vessel inventory deduced from particle balance and the deuterium content of the deposited layers. The study shows that only a third of the estimated deuterium trapped in the vessel is trapped in the carbon deposits. Thus, in the present state of our knowledge and characterisation of the permanent retention, one has to search for mechanisms other than co-deposition to explain the deuterium retention in Tore Supra. (A.C.)

  12. Development of a perpendicular vibration-induced electrical discharge machining process for fabrication of partially wavy inner structures

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ju Chul; Park, Sang Hu; Min, June Kee; Ha, Man Yeong; Shin, Bo Sung [Pusan National University, Busan (Korea, Republic of); Cho, Jong Rae [Korea Maritime University, Busan (Korea, Republic of)

    2016-05-15

    Heat transfer enhancement is an important issue in energy systems. To improve the efficiency of a cooling channel used inside injection molds, turbine blades, and high-temperature devices, channels with various shapes, such as wavy, elliptical, and twisted, have been studied. A cooling channel with a partially wavy inner structure has shown outstanding cooling performance despite a small increase in friction factor. However, generating a partially wavy inner structure inside a channel through conventional machining processes is not easy. To address this problem, we developed a new process called Perpendicular vibration-induced electrical discharge machining (PV-EDM). A specific electrode and one- and random-directional vibrating devices controlled by a pneumatic load were designed for the PV-EDM process. Experimental results showed that local shaping on the inner wall of a channel is possible, which confirmed the possibility of application of this process to actual industrial problems.

  13. The Golden mean, Fibonacci matrices and partial weakly super-increasing sources

    International Nuclear Information System (INIS)

    Esmaeili, M.; Gulliver, T.A.; Kakhbod, A.

    2009-01-01

    A source S={s 1 ,s 2 ,...}, with at least i+1 source symbols, having a binary Huffman code with codeword lengths satisfying l 1 =1,l 2 =2,...,l i =i, is called an i-level partial weakly super-increasing (PWSI) source. Connections between these sources, Fibonacci matrices and the Golden mean are studied. It is shown that the Euclidean projection of the distributions associated with these sources is given by Fibonacci-Hessenberg matrices. While there is no upper bound on the expected codeword length of Huffman codes representing PWSI sources (and hence no upper bound on their entropy), the Fibonacci sequence and the Golden mean (1+√(5))/2 provide a lower bound on the maximum expected codeword length of these codes.

  14. Discharge plasmas as EUV Sources for Future Micro Lithography

    Science.gov (United States)

    Kruecken, Thomas

    2007-08-01

    Future extreme ultraviolet (EUV) lithography will require very high radiation intensities in a narrow wavelength range around 13.5 nm, which is most efficiently emitted as line radiation by highly ionized heavy particles. Currently the most intense EUV sources are based on xenon or tin gas discharges. After having investigated the limits of a hollow cathode triggered xenon pinch discharge Philips Extreme UV favors a laser triggered tin vacuum spark discharge. Plasma and radiation properties of these highly transient discharges will be compared. Besides simple MHD-models the ADAS software package has been used to generate important atomic and spectral data of the relevant ion stages. To compute excitation and radiation properties, collisional radiative equilibria of individual ion stages are computed. For many lines opacity effects cannot be neglected. In the xenon discharges the optical depths allow for a treatment based on escape factors. Due to the rapid change of plasma parameters the abundancies of the different ionization stages must be computed dynamically. This requires effective ionization and recombination rates, which can also be supplied by ADAS. Due to very steep gradients (up to a couple orders of magnitude per mm) the plasma of tin vacuum spark discharges is very complicated. Therefore we shall describe here only some technological aspects of our tin EUV lamp: The electrode system consists of two rotating which are pulled through baths of molten tin such that a tin film remains on their surfaces. With a laser pulse some tin is ablated from one of the wheels and travels rapidly through vacuum towards the other rotating wheel. When the tin plasma reaches the other electrodes it ignites and the high current phase starts, i.e. the capacitor bank is unloaded, the plasma is pinched and EUV is radiated. Besides the good spectral properties of tin this concept has some other advantages: Erosion of electrodes is no severe problem as the tin film is

  15. Low pressure arc discharges with hollow cathodes and their using in plasma generators and charged particle sources

    CERN Document Server

    Vintizenko, L G; Koval, N N; Tolkachev, V S; Lopatin, I V; Shchanin, P M

    2001-01-01

    Paper presents the results of investigation into arc discharges with a hollow cathode generating 10 sup 1 sup 0 -10 sup 1 sup 2 concentration gas-discharge plasma in essential (approx 1 m sup 3) volumes at low (10 sup - sup 2 -1 Pa) pressures and up to 200 A discharge currents. One studied design of discharge systems with heated and cold cathodes their peculiar features, presented the parameters of plasma generators and of charged particle sources based on arc discharges and discussed, as well, the problems of more rational application of those systems in the processes for surface modification of solids

  16. Partial scram incident in FBTR

    International Nuclear Information System (INIS)

    Usha, S.; Pillai, C.P.; Muralikrishna, G.

    1989-01-01

    Evaluation of a partial scram incident occurred at the Fast Breeder Test Reactor at Kalpakkam was carried out. Based on the observations of the experiments it was ascertained that the nonpersistant order was due to superimposed noise component on the channel that was close to the threshold and had resulted in intermittent supply to electro-magnetic (EM) coils. Owing to a larger discharge time and a smaller charge time, the EM coils got progressively discharged. It was confirmed that during the incident, partial scram took place since the charging and discharging patterns of the EM coils are dissimilar and EM coils of rods A, E and F had discharged faster than others for noise component of a particular duty cycle. However, nonlatching of scram order was because of the fact that noise pulse duration was less than latching time. (author)

  17. Monitoring physical properties of a submarine groundwater discharge source at Kalogria Bay, SW Peloponnissos, Greece

    Directory of Open Access Journals (Sweden)

    Papathanassiou E.

    2012-04-01

    Full Text Available An impressive SGD in Kalogria Bay (SW Peloponnissos was surveyed for the first time in 2006, revealing the existence of 2 major and 2 minor point sources of freshwater (salinity ~l-2; the discharge was ~ 1000 m3 h−1. The major point source was located in a karstic cavity at 25 m depth. In July 2009, and for a period of one year, the site was monitored intensively. During summer, the underwater discharge was not very strong, the water was flowing from many dispersed points, and salinity range was 20–36. During autumn and winter, flow velocity increased considerably (> 1 m s−1, and the SGDs discharged water of low salinity (< 2. Gradually, the smaller SGDs ceased their operation, and the major SGD emanated brackish water during spring and summer, thus hampering the possibilities of freshwater exploitation, in a touristic area which suffers from great aridity and water demand is high during summer.

  18. Discharge regimes and density jumps in a helicon plasma source

    International Nuclear Information System (INIS)

    Shinohara, S.; Yonekura, K.

    1999-01-01

    A high density plasma source using a helicon wave is becoming very attractive in plasma processing and confinement devices. In the previous work, the characteristics of this wave and plasma performance with diameters of 5 and 45 cm have been studied, and the helicon wave was only observed after the density jump. Recently, density jumps from the low to high electron densities with a level of 10 13 cm -3 were investigated by changing the antenna wavenumber spectrum, and the obtained results were compared with the inductively coupled plasma (ICP). However, the mechanisms of density jumps and plasma production are still open questions to be answered. Here, the authors try to investigate the discharge regimes and density jumps in a helicon plasma source, by changing the antenna wavenumber spectrum. For he case of the parallel current directions in the antenna, where the low wavenumber spectrum part is large, the density jump was observed with the low RF input power of P in < 300 W regardless of the magnetic field. On the other hand, for the case of the opposite directions, where the low wavenumber spectrum part is small, the threshold power to obtain the jump became high with the increase in the magnetic field. This can be understood from the dispersion relation of the helicon wave. The wave structures and the dispersion relations in the discharge modes will be also shown

  19. Temperature Effect on Electrical Treeing and Partial Discharge Characteristics of Silicone Rubber-Based Nanocomposites

    Directory of Open Access Journals (Sweden)

    Mohd Hafizi Ahmad

    2015-01-01

    Full Text Available This study investigated electrical treeing and its associated phase-resolved partial discharge (PD activities in room-temperature, vulcanized silicone rubber/organomontmorillonite nanocomposite sample materials over a range of temperatures in order to assess the effect of temperature on different filler concentrations under AC voltage. The samples were prepared with three levels of nanofiller content: 0% by weight (wt, 1% by wt, and 3% by wt. The electrical treeing and PD activities of these samples were investigated at temperatures of 20°C, 40°C, and 60°C. The results show that the characteristics of the electrical tree changed with increasing temperature. The tree inception times decreased at 20°C due to space charge dynamics, and the tree growth time increased at 40°C due to the increase in the number of cross-link network structures caused by the vulcanization process. At 60°C, more enhanced and reinforced properties of the silicone rubber-based nanocomposite samples occurred. This led to an increase in electrical tree inception time and electrical tree growth time. However, the PD characteristics, particularly the mean phase angle of occurrence of the positive and negative discharge distributions, were insensitive to variations in temperature. This reflects an enhanced stability in the nanocomposite electrical properties compared with the base polymer.

  20. Partial discharge signal denoising with spatially adaptive wavelet thresholding and support vector machines

    Energy Technology Data Exchange (ETDEWEB)

    Mota, Hilton de Oliveira; Rocha, Leonardo Chaves Dutra da [Department of Computer Science, Federal University of Sao Joao del-Rei, Visconde do Rio Branco Ave., Colonia do Bengo, Sao Joao del-Rei, MG, 36301-360 (Brazil); Salles, Thiago Cunha de Moura [Department of Computer Science, Federal University of Minas Gerais, 6627 Antonio Carlos Ave., Pampulha, Belo Horizonte, MG, 31270-901 (Brazil); Vasconcelos, Flavio Henrique [Department of Electrical Engineering, Federal University of Minas Gerais, 6627 Antonio Carlos Ave., Pampulha, Belo Horizonte, MG, 31270-901 (Brazil)

    2011-02-15

    In this paper an improved method to denoise partial discharge (PD) signals is presented. The method is based on the wavelet transform (WT) and support vector machines (SVM) and is distinct from other WT-based denoising strategies in the sense that it exploits the high spatial correlations presented by PD wavelet decompositions as a way to identify and select the relevant coefficients. PD spatial correlations are characterized by WT modulus maxima propagation along decomposition levels (scales), which are a strong indicative of the their time-of-occurrence. Denoising is performed by identification and separation of PD-related maxima lines by an SVM pattern classifier. The results obtained confirm that this method has superior denoising capabilities when compared to other WT-based methods found in the literature for the processing of Gaussian and discrete spectral interferences. Moreover, its greatest advantages become clear when the interference has a pulsating or localized shape, situation in which traditional methods usually fail. (author)

  1. Development of a short pulsed corona discharge ionization source for ion mobility spectrometry

    International Nuclear Information System (INIS)

    An Yuan; Aliaga-Rossel, R.; Choi, Peter; Gilles, Jean-Paul

    2005-01-01

    The development of a pulsed corona discharge ionization source and its use in ion mobility spectrometry (IMS) is presented. In a point-plane electrode geometry, an electrical pulse up to 12 kV, 150 ns rise time and 500 ns pulse width was used to generate a corona discharge in air. A single positive high voltage pulse was able to generate about 1.6x10 10 ions at energy consumption of 22 μJ. Since the temporal distribution of ions is in a pulsed form, the possibility of removal the ion gate has been investigated. By purposely arranging the interface between discharge field and drift field, nearly 10 7 positive ions were drawn into the drift region with absence of the ion gate after every single discharge. The positive spectrum of acetone dimer (working at room temperature) was obtained with a resolving power of 20 by using this configuration. The advantages of this new scheme are the low power consumption compared with the dc method as well as the simplicity of the IMS cell structure

  2. Classification of PD sources in HV cables using neural networks and the LN-FDTD method

    Energy Technology Data Exchange (ETDEWEB)

    Barros, W.H.; Oliveira, R.M.; Sobrinho, C.L.; Leite, R.C. [Univ. Federal do Para, Para (Brazil). Dept. of Computational and Electrical Engineering

    2008-07-01

    Partial discharges can be generated by the presence of several defects, and are often the cause of failures in electrical equipment insulators. In this study, a local non-orthogonal finite difference time-domain method (LN-FDTD) was used to simulate the sources of partial discharges in a high voltage coaxial cable model. The artificial neural network (ANN) technique used a Marquandt-Levenberg training algorithm to detect and classify cable PD sources. A set of harmonics obtained from the difference between the registered signals in the time domain was used as part of the training procedure. A failure was inserted on an electrical cable in each simulation in order to obtain the correlated data. Input signals were injected using a voltage pulse represented by a Gaussian function. A total of 90 simulations were conducted to generate 360 data groups in order to consider 6 different types of failures. Results of the study showed that the method can be used to detect and classify partial discharges in cables. 12 refs., 21 figs.

  3. Influence of void defects on partial discharge behavior of superconducting busbar insulation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Chunyu; Huang, Xiongyi, E-mail: huangxy@ipp.ac.cn; Lu, Kun; Li, Guoliang; Zhu, Haisheng; Wang, Jun; Wang, Cao; Dai, Zhiheng; Fang, Linlin; Song, Yuntao

    2017-06-15

    Highlights: • PD detection method was used to check the quality of the superconducting busbar insulation. • The samples with different void fraction were manufactured for comparing. • The discharge inception voltage, PRPD pattern was tested and studied for the samples with different void content. • The PD behaviors in oil bath and air condition were compared. - Abstract: For a magnetic confinement fusion device, the superconducting magnets and busbars need to be insulated with one layer of solid insulation to isolate the high voltage potential from the ground. The insulation layer commonly consists of several interleaved layers of epoxy resin-impregnated glass fiber tapes and polyimide films. The traditional electrical inspection methods for such solidified insulation on the magnet and busbar are a DC voltage test or a Paschen test. These tests measure the quality of the insulation based on the value of leakage currents. However, even if there is a larger quantity of high dielectric strength material implemented, if there are some microcavities or delaminations in the insulation system, the leakage current may be limited to microampere levels under testing levels over dozens of kilovolts. Therefore, it is difficult to judge the insulation quality just by the magnitudes of leakage current. Under long-term operation, such imperceptible defects will worsen and finally completely break down the insulation because of partial discharge (PD) incidents. Therefore, a PD detection test is an important complement to the DC voltage and Paschen tests for magnet and busbar insulations in the field of fusion. It is known that the PD detection test is a mature technique in the electric power industry. In this paper, the PD characteristics of samples containing glass fiber-reinforced composite insulations for use with the superconducting busbar were presented and discussed. Various samples with different void contents were prepared and the PD behaviors were tested.

  4. Influence of void defects on partial discharge behavior of superconducting busbar insulation

    International Nuclear Information System (INIS)

    Wang, Chunyu; Huang, Xiongyi; Lu, Kun; Li, Guoliang; Zhu, Haisheng; Wang, Jun; Wang, Cao; Dai, Zhiheng; Fang, Linlin; Song, Yuntao

    2017-01-01

    Highlights: • PD detection method was used to check the quality of the superconducting busbar insulation. • The samples with different void fraction were manufactured for comparing. • The discharge inception voltage, PRPD pattern was tested and studied for the samples with different void content. • The PD behaviors in oil bath and air condition were compared. - Abstract: For a magnetic confinement fusion device, the superconducting magnets and busbars need to be insulated with one layer of solid insulation to isolate the high voltage potential from the ground. The insulation layer commonly consists of several interleaved layers of epoxy resin-impregnated glass fiber tapes and polyimide films. The traditional electrical inspection methods for such solidified insulation on the magnet and busbar are a DC voltage test or a Paschen test. These tests measure the quality of the insulation based on the value of leakage currents. However, even if there is a larger quantity of high dielectric strength material implemented, if there are some microcavities or delaminations in the insulation system, the leakage current may be limited to microampere levels under testing levels over dozens of kilovolts. Therefore, it is difficult to judge the insulation quality just by the magnitudes of leakage current. Under long-term operation, such imperceptible defects will worsen and finally completely break down the insulation because of partial discharge (PD) incidents. Therefore, a PD detection test is an important complement to the DC voltage and Paschen tests for magnet and busbar insulations in the field of fusion. It is known that the PD detection test is a mature technique in the electric power industry. In this paper, the PD characteristics of samples containing glass fiber-reinforced composite insulations for use with the superconducting busbar were presented and discussed. Various samples with different void contents were prepared and the PD behaviors were tested.

  5. An ion source for radiofrequency-pulsed glow discharge time-of-flight mass spectrometry

    International Nuclear Information System (INIS)

    González Gago, C.; Lobo, L.; Pisonero, J.; Bordel, N.; Pereiro, R.; Sanz-Medel, A.

    2012-01-01

    A Grimm-type glow discharge (GD) has been designed and constructed as an ion source for pulsed radiofrequency GD spectrometry when coupled to an orthogonal time of flight mass spectrometer. Pulse shapes of argon species and analytes were studied as a function of the discharge conditions using a new in-house ion source (UNIOVI GD) and results have been compared with a previous design (PROTOTYPE GD). Different behavior and shapes of the pulse profiles have been observed for the two sources evaluated, particularly for the plasma gas ionic species detected. In the more analytically relevant region (afterglow), signals for 40 Ar + with this new design were negligible, while maximum intensity was reached earlier in time for 41 (ArH) + than when using the PROTOTYPE GD. Moreover, while maximum 40 Ar + signals measured along the pulse period were similar in both sources, 41 (ArH) + and 80 (Ar 2 ) + signals tend to be noticeable higher using the PROTOTYPE chamber. The UNIOVI GD design was shown to be adequate for sensitive direct analysis of solid samples, offering linear calibration graphs and good crater shapes. Limits of detection (LODs) are in the same order of magnitude for both sources, although the UNIOVI source provides slightly better LODs for those analytes with masses slightly higher than 41 (ArH) + . - Highlights: ► A new RF-pulsed GD ion source (UNIOVI GD) coupled to TOFMS has been characterized. ► Linear calibration graphs and LODs in the low ppm range are achieved. ► Craters with flat bottoms and vertical walls are obtained. ► UNIOVI source can be easily cleaned as it does not require flow tube. ► UNIOVI GD has a simple design and thus its manufacture is easy and cheap.

  6. Diagnostics of a negative hydrogen ion source based on a planar-coil inductively-driven discharge

    International Nuclear Information System (INIS)

    Lishev, Stiliyan St.; Shivarova, Antonia P.; Iordanov, Dimitar I.; Todorov, Dimitar T.; Demerdzhiev, Angel P.

    2013-01-01

    Recent activity on a volume-production negative-hydrogen-ion source with the design of a matrix of small-radius discharges inductively driven by a planar coil is reported. A single discharge of the matrix has been studied by employing probe-and laser-photodetachment diagnostics. The measurements have been carried out in the first - small-size - chamber of a two-chamber discharge vessel, with rf power introduced by a planar coil positioned on its front wall. The measured profiles of the negative ion density show strong axial dependence, with two maxima located at the positions corresponding to the maxima of the dc potential, where the maxima of the electron density are also located. The first maximum is in the vicinity of the rf power input and the second one is close to the interface between the two chambers of the discharge vessel.

  7. Excited Atoms and Molecules in High Pressure Gas Discharges

    International Nuclear Information System (INIS)

    Vuskovic, L.; Popovic, S.

    2003-01-01

    Various types of high-pressure non-thermal discharges are increasingly drawing attention in view of many interesting applications. These, partially ionized media in non-equilibrium state, tend to generate complex effects that are difficult to interpret without a detailed knowledge of elementary processes involved. Electronically excited molecules and atoms may play an important role as intermediate states in a wide range of atomic and molecular processes, many of which are important in high-pressure discharges. They can serve also as reservoirs of energy or as sources of high energy electrons either through the energy pooling or through superelastic collisions. By presenting the analysis of current situation on the processes involving excited atoms and molecules of interest for high-pressure gas discharges, we will attempt to draw attention on the insufficiency of available data. In the same time we will show how to circumvent this situation and still be able to develop accurate models and interpretations of the observed phenomena

  8. Approximations to the electron energy distribution and positive column models for low-pressure discharge light sources

    International Nuclear Information System (INIS)

    Lister, G G; Sheverev, V A; Uhrlandt, D

    2002-01-01

    The applicability of 'fluid' models based on analytic approximations of the electron energy distribution function (EEDF) and of kinetic models for low-pressure discharge light sources is discussed. Traditionally, 'fluid' models of fluorescent lamps assume that the EEDF is Maxwellian up to the energy of the first excited state. It is shown that such an approach is sufficiently accurate in most cases of conventional as well as of 'highly loaded' fluorescent lamps. However, this assumption is strongly violated for many rare gas glow discharges for mercury free light sources. As an example, a neon dc discharge is studied. The densities of the four lowest excited states and the electric field have been measured. The experimental results can be fairly well reproduced by a kinetic positive column model. This article was scheduled to appear in issue 14 of J. Phys. D: Appl. Phys. To access this special issue please follow this link: http://stacks.iop.org/0022-3727/35/i=14/

  9. Partial discharge as a stator winding evaluation tool

    International Nuclear Information System (INIS)

    Maughan, C.V.

    2005-01-01

    This paper has been prepared to illustrate the value of partial discharge (PD) testing in assessing the condition of stator windings on operating generators and motors. The database of one particular PD system vendor was chosen for this study because of the magnitude of data accumulated by this company over the last 15 years. It was felt that sufficient data had been accumulated to allow useful statistical analysis of the capabilities of PD testing. The PD detection technology used by Iris has been installed on about 6000 generators and motors, and has inspection information from about 3600 machines. On these 3600 generators and motors, PD has successfully identified 209 potential problems that were verified by inspection to be present. In most cases, moderate corrective maintenance permitted return of the equipment to service without major repairs. An estimate of the actual number of avoided failures was not possible from the available reports. But it is clear that many potentially serious stator winding failures were avoided as a result of removal of these machines from service because of high PD readings. No attempt has been made in the paper to provide technical background or details of the PD test/analysis processes. There are numerous technical papers and industry guides; the interested reader is referred to IEEE 1434, EPRI Reports, and other documents in the Bibliography. While this paper is based somewhat narrowly on data from only one company, there are several other companies involved in PD testing and evaluation. As described below in this paper, these companies have also been successful in identifying stator winding problems through the use of PD equipment. Clearly, PD testing is a useful tool in monitoring and assessing the condition of stator windings, as well as other associated electrical equipment in the power plant. Because of the power of PD testing, it is expected that the use of PD monitoring will continue to expand at a significant rate in

  10. The design and characteristics of direct current glow discharge atomic emission source operated with plain and hollow cathodes

    International Nuclear Information System (INIS)

    Qayyum, A.; Mahmood, M.I.

    2008-01-01

    A compact direct current glow discharge atomic emission source has been designed and constructed for analytical applications. This atomic emission source works very efficiently at a low-input electrical power. The design has some features that make it distinct from that of the conventional Grimm glow discharge source. The peculiar cathode design offered greater flexibility on size and shape of the sample. As a result the source can be easily adopted to operate in Plain or Hollow Cathode configuration. I-V and spectroscopic characteristics of the source were compared while operating it with plain and hollow copper cathodes. It was observed that with hollow cathode, the source can be operated at a less input power and generates greater Cu I and Cu II line intensities. Also, the intensity of Cu II line rise faster than Cu I line with argon pressure for both cathodes. But the influence of pressure on Cu II lines was more significant when the source is operated with hollow cathode

  11. Modulating Function-Based Method for Parameter and Source Estimation of Partial Differential Equations

    KAUST Repository

    Asiri, Sharefa M.

    2017-01-01

    Partial Differential Equations (PDEs) are commonly used to model complex systems that arise for example in biology, engineering, chemistry, and elsewhere. The parameters (or coefficients) and the source of PDE models are often unknown

  12. The optimisation of an intense Z-pinch discharge as a plasma source for absorption spectroscopy investigations

    International Nuclear Information System (INIS)

    Sandolache, Gabriela; Zoita, Vasile; Iova, Iancu; Fleurier, Claude; Hong, Dunpin; Bauchire, Jean Marc

    2002-01-01

    The characterisation of the low voltage circuit breaker arc from the optical and plasma physics points of view represents an element of importance for understanding the operating mechanism and the current interruption process. The development of the broad band optical absorption spectroscopy method seems to be well adapted in order to perform the circuit breaker arc analysis. A pulsed power device based on a Z-pinch type discharge has been developed as a plasma source for absorption spectroscopy investigations. The spatial extension of this radiation source, its brightness, reproducibility are well adapted to characterize the circuit-breaker arc. In addition, a very short emission period compared to the lifetime of the arc discharge provides an excellent time resolution for the absorption spectroscopy method. The first compression phase of the linear pinch produced in argon has been studied from the point of view of its use as a light source. The initial pressure of argon was varied from 0.5 to 2 mbar and the condenser bank energy from 5.1 to 8.7 kJ. The characterization of the emitted radiation, especially the influence of the condenser bank voltage and the argon pressure on the discharge has been studied. Collapse dynamics of the argon compressional pinch and the spectrally resolved continuum emission at the time of maximum compression have been observed. A very satisfactory plasma source optimisation has been achieved that fulfils the conditions required for the absorption spectroscopy method. (authors)

  13. Hydrogen isotopic spectral determination in inert gases with the use of light source with contracted discharge

    International Nuclear Information System (INIS)

    Nemets, V.M.; Solov'ev, A.A.

    1981-01-01

    Isotopic-spectral technique for hydrogen determination in helium, neon and argon is developed. It employs a contracted high-frequency discharge as a light source to decrease the distorting effect. of a dummy signal and the ''memory'' effect of the discharge tube. The discharge is realized in a quartz tube approximately 7 mm dia. and gas pressure in it approximately 6x10 4 Pa. The analysis technique comprises sampling of gas, dosed introduction of deuterium into the sample, selection of a mixture portion into the discharge tube, spectroscopic determination of hydrogen isotope ratio and calculation of the sought for hydrogen concentration. The lower boundary of the determined concentrations of hydrogen constitutes 7x10 - 5 , 2x10 - 4 and 4x10 - 4 volumetric per cent in helium, neon, and argon, respectively

  14. Can Concentration - Discharge Relationships Diagnose Material Source During Extreme Events?

    Science.gov (United States)

    Karwan, D. L.; Godsey, S.; Rose, L.

    2017-12-01

    Floods can carry >90% of the basin material exported in a given year as well as alter flow pathways and material sources. In turn, sediment and solute fluxes can increase flood damages and negatively impact water quality and integrate physical and chemical weathering of landscapes and channels. Concentration-discharge (C-Q) relationships are used to both describe export patterns as well as compute them. Metrics for describing C-Q patterns and inferring their controls are vulnerable to infrequent sampling that affects how C-Q relationships are interpolated and interpreted. C-Q relationships are typically evaluated from multiple samples, but because hydrological extremes are rare, data are often unavailable for extreme events. Because solute and sediment C-Q relationships likely respond to changes in hydrologic extremes in different ways, there is a pressing need to define their behavior under extreme conditions, including how to properly sample to capture these patterns. In the absence of such knowledge, improving load estimates in extreme floods will likely remain difficult. Here we explore the use of C-Q relationships to determine when an event alters a watershed system such that it enters a new material source/transport regime. We focus on watersheds with sediment and discharge time series include low-frequency and/or extreme events. For example, we compare solute and sediment patterns in White Clay Creek in southeastern Pennsylvania across a range of flows inclusive of multiple hurricanes for which we have ample ancillary hydrochemical data. TSS is consistently mobilized during high flow events, even during extreme floods associated with hurricanes, and sediment fingerprinting indicates different sediment sources, including in-channel remobilization and landscape erosion, are active at different times. In other words, TSS mobilization in C-Q space is not sensitive to the source of material being mobilized. Unlike sediments, weathering solutes in this watershed

  15. Atmospheric-pressure solution-cathode glow discharge: A versatile ion source for atomic and molecular mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, Andrew J. [Department of Chemistry, Indiana University, Bloomington, IN, 47405 (United States); Williams, Kelsey L. [Department of Chemistry and Biochemistry, Kent State University, Kent, OH, 44242 (United States); Hieftje, Gary M. [Department of Chemistry, Indiana University, Bloomington, IN, 47405 (United States); Shelley, Jacob T., E-mail: shellj@rpi.edu [Department of Chemistry and Biochemistry, Kent State University, Kent, OH, 44242 (United States); Department of Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, Troy, NY, 12180 (United States)

    2017-01-15

    An atmospheric-pressure solution-cathode glow discharge (SCGD) has been evaluated as an ion source for atomic, molecular, and ambient desorption/ionization mass spectrometry. The SCGD consists of a direct-current plasma, supported in the ambient air in the absence of gas flows, and sustained upon the surface of a flowing liquid cathode. Analytes introduced in the flowing liquid, as an ambient gas, or as a solid held near the plasma are vaporized and ionized by interactions within or near the discharge. Introduction of acidic solutions containing metal salts produced bare elemental ions as well as H{sub 2}O, OH{sup −} and NO{sub 3}{sup −} adducts. Detection limits for these elemental species ranged from 0.1 to 4 ppb, working curves spanned more than 4 orders of linear dynamic range, and precision varied between 5 and 16% relative standard deviation. Small organic molecules were also efficiently ionized from solution, and both the intact molecular ion and fragments were observed in the resulting SCGD mass spectra. Fragmentation of molecular species was found to be tunable; high discharge currents led to harder ionization, while low discharge currents produced stronger molecular-ion signals. Ambient gases and solids, desorbed by the plasma from a glass probe, were also readily ionized by the SCGD. Indeed, strong analyte signals were obtained from solid samples placed at least 2 cm from the plasma. These findings indicate that the SCGD might be useful also for ambient desorption/ionization mass spectrometry. Combined with earlier results that showed the SCGD is useful for ionization of labile biomolecules, the results here indicate that the SCGD is a highly versatile ion source capable of providing both elemental and molecular mass-spectral information. - Highlights: • Solution-cathode glow discharge used as an ionization source for mass spectrometry. • SCGD-MS can provide atomic as well as intact molecular mass spectra. • Atomic limits of detection range

  16. Comparison of dielectric barrier discharge, atmospheric pressure radiofrequency-driven glow discharge and direct analysis in real time sources for ambient mass spectrometry of acetaminophen

    Energy Technology Data Exchange (ETDEWEB)

    Kratzer, Jan [Institute for National Measurement Standards, National Research Council of Canada, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada); Institute of Analytical Chemistry of the ASCR, v.v.i., Veveri 97, CZ-602 00 Brno (Czech Republic); Mester, Zoltan [Institute for National Measurement Standards, National Research Council of Canada, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada); Sturgeon, Ralph E., E-mail: Ralph.Sturgeon@nrc-cnrc.gc.ca [Institute for National Measurement Standards, National Research Council of Canada, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada)

    2011-08-15

    Three plasma-based ambient pressure ion sources were investigated; laboratory constructed dielectric barrier and rf glow discharges, as well as a commercial corona discharge (DART source). All were used to desorb and ionize a model analyte, providing sampling techniques for ambient mass spectrometry (MS). Experimental parameters were optimized to achive highest signal for acetaminophen as the analyte. Insight into the mechanisms of analyte desorption and ionization was obtained by means of emission spectrometry and ion current measurements. Desorption and ionization mechanisms for this analyte appear to be identical for all three plasma sources. Emission spectra differ only in the intensities of various lines and bands. Desorption of solid analyte requires transfer of thermal energy from the plasma source to sample surface, in the absence of which complete loss of MS response occurs. For acetaminophen, helium was the best plasma gas, providing 100- to 1000-fold higher analyte response than with argon or nitrogen. The same trend was also evident with background ions (protonated water clusters). MS analyte signal intensity correlates with the ion density (expressed as ion current) in the plasma plume and with emission intensity from excited state species in the plasma. These observations support an ionization process which occurs via proton transfer from protonated water clusters to analyte molecules.

  17. Evaluation efficiency for mobile as discharge measurement device for partially filled circular channel

    Directory of Open Access Journals (Sweden)

    I.M.H. Rashwan

    2013-06-01

    Full Text Available Discharge measurement is an important step in engineering applications such as sewerage system, irrigation and drainage system. Mobile flume is a simple and low-cost discharge measuring device constructed of two pieces of pipes, one installed vertically inside the other. The circular mobile flume depends on the concept of developing a contracted zone to have a control section. To evaluate the efficiency of this type of device mathematical and experimental studies are presented. Specific energy, discharge and Froude number equations are used to develop mathematical model. Experimental work is carried out to measure the discharge values corresponding to the specific energy values. The experimental data is used to evaluate the mobile flume as a device to measure discharge. A new equation for the discharge coefficient is presented. This equation can be used to determined accurate discharge with knowing the contraction ratio and measured specific energy.

  18. Partial podocyte replenishment in experimental FSGS derives from nonpodocyte sources.

    Science.gov (United States)

    Kaverina, Natalya V; Eng, Diana G; Schneider, Remington R S; Pippin, Jeffrey W; Shankland, Stuart J

    2016-06-01

    The current studies used genetic fate mapping to prove that adult podocytes can be partially replenished following depletion. Inducible NPHS2-rtTA/tetO-Cre/RS-ZsGreen-R reporter mice were generated to permanently label podocytes with the ZsGreen reporter. Experimental focal segmental glomerulosclerosis (FSGS) was induced with a cytotoxic podocyte antibody. On FSGS day 7, immunostaining for the podocyte markers p57, synaptopodin, and podocin were markedly decreased by 44%, and this was accompanied by a decrease in ZsGreen fluorescence. The nuclear stain DAPI was absent in segments of reduced ZsGreen and podocyte marker staining, which is consistent with podocyte depletion. Staining for p57, synaptopodin, podocin, and DAPI increased at FSGS day 28 and was augmented by the ACE inhibitor enalapril, which is consistent with a partial replenishment of podocytes. In contrast, ZsGreen fluorescence did not return and remained significantly low at day 28, indicating replenishment was from a nonpodocyte origin. Despite administration of bromodeoxyuridine (BrdU) thrice weekly throughout the course of disease, BrdU staining was not detected in podocytes, which is consistent with an absence of proliferation. Although ZsGreen reporting was reduced in the tuft at FSGS day 28, labeled podocytes were detected along the Bowman's capsule in a subset of glomeruli, which is consistent with migration from the tuft. Moreover, more than half of the migrated podocytes coexpressed the parietal epithelial cell (PEC) proteins claudin-1, SSeCKS, and PAX8. These results show that although podocytes can be partially replenished following abrupt depletion, a process augmented by ACE inhibition, the source or sources are nonpodocyte in origin and are independent of proliferation. Furthermore, a subset of podocytes migrate to the Bowman's capsule and begin to coexpress PEC markers. Copyright © 2016 the American Physiological Society.

  19. Alfven wave propagation in a partially ionized plasma

    International Nuclear Information System (INIS)

    Watts, Christopher; Hanna, Jeremy

    2004-01-01

    Results from a laboratory study of the dispersion relation of Alfven waves propagating through a partially ionized plasma are presented. The plasma is generated using a helicon source, creating a high density, current-free discharge, where the source can be adjusted to one of several modes with varying neutral fraction. Depending on the neutral fraction, the measured dispersion curve of shear Alfven waves can change significantly. Measurement results are compared with theoretical predictions of the effect of neutral particles on Alfven wave propagation. In fitting the theory, the neutral fraction is independently estimated using two simple particle transport models, one collisionless, the other collisional. The two models predict comparable neutral fractions, and agree well with the neutral fraction required for the Alfven dispersion theory

  20. Experimental Evaluation of Discharge Characteristics in Inhomogeneous Fields under Air Flow

    DEFF Research Database (Denmark)

    Vogel, Stephan; Holbøll, Joachim

    2018-01-01

    voltages and a laminar air flow up to 22 m/s. In the first setup, the gap was exposed to a variable DC potential of up to 100 kV in order to create space charges in the vicinity of the electrode. The impact of the air flow on partial discharges and the dynamic behavior of the space charges is evaluated...... by means of partial discharge measurement and ultraviolet photography. The results show that the air flow increases the frequency of partial discharges in the gap due to an increased rate of space charge removal in the high field area around the tip of the electrode. The partial discharge behavior shows...... higher dependency on air flow at positive tip polarity as compared to the negative polarity. In the second setup, the standard impulse voltage created by a multistage impulse voltage generator was superimposed to a DC voltage, which continuously created corona and space charges around the tip...

  1. Sources of Magmatic Volatiles Discharging from Subduction Zone Volcanoes

    Science.gov (United States)

    Fischer, T.

    2001-05-01

    Subduction zones are locations of extensive element transfer from the Earth's mantle to the atmosphere and hydrosphere. This element transfer is significant because it can, in some fashion, instigate melt production in the mantle wedge. Aqueous fluids are thought to be the major agent of element transfer during the subduction zone process. Volatile discharges from passively degassing subduction zone volcanoes should in principle, provide some information on the ultimate source of magmatic volatiles in terms of the mantle, the crust and the subducting slab. The overall flux of volatiles from degassing volcanoes should be balanced by the amount of volatiles released from the mantle wedge, the slab and the crust. Kudryavy Volcano, Kurile Islands, has been passively degassing at 900C fumarole temperatures for at least 40 years. Extensive gas sampling at this basaltic andesite cone and application of CO2/3He, N2/3He systematics in combination with C and N- isotopes indicates that 80% of the CO2 and approximately 60% of the N 2 are contributed from a sedimentary source. The mantle wedge contribution for both volatiles is, with 12% and 17% less significant. Direct volatile flux measurements from the volcano using the COSPEC technique in combination with direct gas sampling allows for the calculation of the 3He flux from the volcano. Since 3He is mainly released from the astenospheric mantle, the amount of mantle supplying the 3He flux can be determined if initial He concentrations of the mantle melts are known. The non-mantle flux of CO2 and N2 can be calculated in similar fashion. The amount of non-mantle CO2 and N2 discharging from Kudryavy is balanced by the amount of CO2 and N2 subducted below Kudryavy assuming a zone of melting constrained by the average spacing of the volcanoes along the Kurile arc. The volatile budget for Kudryavy is balanced because the volatile flux from the volcano is relatively small (75 t/day (416 Mmol/a) SO2, 360 Mmol/a of non-mantle CO2 and

  2. The influence of spherical cavity surface charge distribution on the sequence of partial discharge events

    International Nuclear Information System (INIS)

    Illias, Hazlee A; Chen, George; Lewin, Paul L

    2011-01-01

    In this work, a model representing partial discharge (PD) behaviour of a spherical cavity within a homogeneous dielectric material has been developed to study the influence of cavity surface charge distribution on the electric field distribution in both the cavity and the material itself. The charge accumulation on the cavity surface after a PD event and charge movement along the cavity wall under the influence of electric field magnitude and direction has been found to affect the electric field distribution in the whole cavity and in the material. This in turn affects the likelihood of any subsequent PD activity in the cavity and the whole sequence of PD events. The model parameters influencing cavity surface charge distribution can be readily identified; they are the cavity surface conductivity, the inception field and the extinction field. Comparison of measurement and simulation results has been undertaken to validate the model.

  3. The influence of spherical cavity surface charge distribution on the sequence of partial discharge events

    Energy Technology Data Exchange (ETDEWEB)

    Illias, Hazlee A [Department of Electrical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia); Chen, George; Lewin, Paul L, E-mail: h.illias@um.edu.my [Tony Davies High Voltage Laboratory, School of Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ (United Kingdom)

    2011-06-22

    In this work, a model representing partial discharge (PD) behaviour of a spherical cavity within a homogeneous dielectric material has been developed to study the influence of cavity surface charge distribution on the electric field distribution in both the cavity and the material itself. The charge accumulation on the cavity surface after a PD event and charge movement along the cavity wall under the influence of electric field magnitude and direction has been found to affect the electric field distribution in the whole cavity and in the material. This in turn affects the likelihood of any subsequent PD activity in the cavity and the whole sequence of PD events. The model parameters influencing cavity surface charge distribution can be readily identified; they are the cavity surface conductivity, the inception field and the extinction field. Comparison of measurement and simulation results has been undertaken to validate the model.

  4. ZVI-Clay remediation of a chlorinated solvent source zone, Skuldelev, Denmark: 2. Groundwater contaminant mass discharge reduction

    DEFF Research Database (Denmark)

    Fjordbøge, Annika Sidelmann; Lange, Ida Vedel; Bjerg, Poul Løgstrup

    2012-01-01

    The impact of source mass depletion on the down-gradient contaminant mass discharge was monitored for a 19-month period as a part of a field demonstration of the ZVI-Clay soil mixing remediation technology. Groundwater samples were collected from conventional monitoring wells (120 samples) and a ...... down-gradient contaminant mass discharge reduction (76%) for the parent compound (PCE), while the overall reduction of chlorinated ethenes was smaller (21%)....

  5. Glow discharge lamp: a light source for optical emission spectroscopy

    International Nuclear Information System (INIS)

    Vishwanathan, K.S.; Srinivasan, V.; Nalini, S.; Mahalingam, T.R.

    1990-01-01

    A glow discharge lamp based on a modified version of the Grimm design has been fabricated. Its utility as a radiation source for optical emmission spectrography by standardising a method for the analysis of low alloy steels using a set of certified standards from DMRL, Hyderabad, has been demonstrated. A model has been proposed where the sputtering rates of different metals have been correlated with their heats of sublimation, metallic radii and densities. Sputtering rates of ten different metals obtained from literature have been used to test this model, and the correlation appears to be excellent. (author). 19 re fs., 13 figs., 2 tabs

  6. Measuring system of partial discharges with optical links and interphase for PC; Sistema de medicion de descargas parciales con enlaces opticos e interfase para PC

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco Arteaga, Maria Jojutla Olimpia

    1999-07-01

    In this work a measuring system of partial discharges based on the traditional electrical detection technique is presented, but that unlike the existing systems it uses an optical link of communication. On one hand, the optical fiber avoids that the electromagnetic interference of the area affects the measurement and on the other hand, allows to make measurements online. With a personal computer and an application program the system is controlled, besides storing and displaying graphically the acquired data. As a result of this thesis the developed system obtains the magnitude and the phase of every partial discharge occurred during a time interval fixed or selected by the user, as well as the total number of discharges. In a graphical form it presents the magnitude and the phase of each discharge, in addition to the corresponding histogram of frequencies. [Spanish] En este trabajo se presenta un sistema de medicion de descargas parciales basado en la tecnica de deteccion electrica tradicional, pero que a diferencia de los sistemas existentes utiliza un enlace de comunicacion optico. Por un lado, la fibra optica evita que la interferencia electromagnetica del medio afecte la medicion y por otro, permite hacer mediciones en linea. Con una computadora personal y un programa de aplicacion se controla el sistema, ademas de almacenar y presentar graficamente la informacion adquirida. Como resultado de esta tesis el sistema desarrollado obtiene la magnitud y la fase de cada descarga parcial ocurrida durante un intervalo de tiempo fijo o seleccionado por el usuario, asi como el numero total de descargas. En forma grafica presenta la magnitud y la fase de cada descarga, ademas del histograma de frecuencias correspondiente.

  7. Estimating sedimentation rates and sources in a partially urbanized catchment using caesium-137

    Science.gov (United States)

    Ormerod, L. M.

    1998-06-01

    While there has been increased interest in determining sedimentation rates and sources in agricultural and forested catchments in recent years, there have been few studies dealing with urbanized catchments. A study of sedimentation rates and sources within channel and floodplain deposits of a partially urbanized catchment has been undertaken using the 137Cs technique. Results for sedimentation rates showed no particular downstream pattern. This may be partially explained by underestimation of sedimentation rates at some sites by failure to sample the full 137Cs profile, floodplain erosion and deliberate removal of sediment. Evidence of lateral increases in net sedimentation rates with distance from the channel may be explained by increased floodplain erosion at sites closer to the channel and floodplain formation by lateral deposition. Potential sediment sources for the catchment were considered to be forest topsoil, subsurface material and sediments derived from urban areas, which were found to be predominantly subsurface material. Tracing techniques showed an increase in subsurface material for downstream sites, confirming expectations that subsurface material would increase in the downstream direction in response to the direct and indirect effects of urbanization.

  8. Resonant Frequency Calculation and Optimal Design of Peano Fractal Antenna for Partial Discharge Detection

    Directory of Open Access Journals (Sweden)

    Jian Li

    2012-01-01

    Full Text Available Ultra-high-frequency (UHF approaches have caught increasing attention recently and have been considered as a promising technology for online monitoring partial discharge (PD signals. This paper presents a Peano fractal antenna for UHF PD online monitoring of transformer with small size and multiband. The approximate formula for calculating the first resonant frequency of the Peano fractal antenna is presented. The results show that the first resonant frequency of the Peano fractal antenna is smaller than the Hilbert fractal antenna when the outer dimensions are equivalent approximately. The optimal geometric parameters of the antenna were obtained through simulation. Actual PD experiments had been carried out for two typically artificial insulation defect models, while the proposed antenna and the existing Hilbert antenna were both used for the PD measurement. The experimental results show that Peano fractal antenna is qualified for PD online UHF monitoring and a little more suitable than the Hilbert fractal antenna for pattern recognition by analyzing the waveforms of detected UHF PD signals.

  9. Characteristics of cold atmospheric plasma source based on low-current pulsed discharge with coaxial electrodes

    Science.gov (United States)

    Bureyev, O. A.; Surkov, Yu S.; Spirina, A. V.

    2017-05-01

    This work investigates the characteristics of the gas discharge system used to create an atmospheric pressure plasma flow. The plasma jet design with a cylindrical graphite cathode and an anode rod located on the axis of the system allows to realize regularly reproducible spark breakdowns mode with a frequency ∼ 5 kHz and a duration ∼ 40 μs. The device generates a cold atmospheric plasma flame with 1 cm in diameter in the flow of various plasma forming gases including nitrogen and air at about 100 mA average discharge current. In the described construction the cathode spots of individual spark channels randomly move along the inner surface of the graphite electrode creating the secondary plasma stream time-average distributed throughout the whole exit aperture area after the decay of numerous filamentary discharge channels. The results of the spectral diagnostics of plasma in the discharge gap and in the stream coming out of the source are presented. Despite the low temperature of atoms and molecules in plasma stream the cathode spots operation with temperature of ∼ 4000 °C at a graphite electrode inside a discharge system enables to saturate the plasma by CN-radicals and atomic carbon in the case of using nitrogen as the working gas.

  10. Dielectric barrier discharges: progress on plasma sources and on the understanding of regimes and single filaments

    Science.gov (United States)

    Brandenburg, Ronny

    2017-05-01

    Dielectric barrier discharges (DBDs) are plasmas generated in configurations with an insulating (dielectric) material between the electrodes which is responsible for a self-pulsing operation. DBDs are a typical example of nonthermal atmospheric or normal pressure gas discharges. Initially used for the generation of ozone, they have opened up many other fields of application. Therefore DBDs are a relevant tool in current plasma technology as well as an object for fundamental studies. Another motivation for further research is the fact that so-called partial discharges in insulated high voltage systems are special types of DBDs. The breakdown processes, the formation of structures, and the role of surface processes are currently under investigation. This review is intended to give an update to the already existing literature on DBDs considering the research and development within the last two decades. The main principles and different modes of discharge generation are summarized. A collection of known as well as special electrode configurations and reactor designs will be presented. This shall demonstrate the different and broad possibilities, but also the similarities and common aspects of devices for different fields of applications explored within the last years. The main part is devoted to the progress on the investigation of different aspects of breakdown and plasma formation with the focus on single filaments or microdischarges. This includes a summary of the current knowledge on the electrical characterization of filamentary DBDs. In particular, the recent new insights on the elementary volume and surface memory mechanisms in these discharges will be discussed. An outlook for the forthcoming challenges on research and development will be given.

  11. Experimental Investigation of the Corona Discharge in Electrical Transmission due to AC/DC Electric Fields

    Directory of Open Access Journals (Sweden)

    Fuangpian Phanupong

    2016-01-01

    Full Text Available Nowadays, using of High Voltage Direct Current (HVDC transmission to maximize the transmission efficiency, bulk power transmission, connection of renewable power source from wind farm to the grid is of prime concern for the utility. However, due to the high electric field stress from Direct Current (DC line, the corona discharge can easily be occurred at the conductor surface leading to transmission loss. Therefore, the polarity effect of DC lines on corona inception and breakdown voltage should be investigated. In this work, the effect of DC polarity and Alternating Current (AC field stress on corona inception voltage and corona discharge is investigated on various test objects, such as High Voltage (HV needle, needle at ground plane, internal defect, surface discharge, underground cable without cable termination, cable termination with simulated defect and bare overhead conductor. The corona discharge is measured by partial discharge measurement device with high-frequency current transformer. Finally, the relationship between supply voltage and discharge intensity on each DC polarity and AC field stress can be successfully determined.

  12. Ignition method of corona discharge with modulation of the field in ion source of ion mobility spectrometer

    International Nuclear Information System (INIS)

    Gromov, Evgeniy

    2011-01-01

    The new method for the ignition of the corona discharge has been developed, which improves the stability of the ion mobility spectrometer and the resolution of the instrument. The system of forming a corona discharge without additional electrodes, which are used in a number of known structures for the pre-ionization, has been developed. This simplifies the design of the proposed source and an electronic control circuit. IMS technology is widely used in different civil and military fields for vapor-phase detection of explosive, narcotics, chemical warfare agents, biology molecules and so on. There are set of methods whose are used for the ionization of molecules under analysis. They are the following: radioactive ionization, ultraviolet photoionization, laser ionization, electric field ionization, corona spray ionization, electro spray ionization, roentgen ionization, and surface ionization. All these methods has their own advantages and disadvantages. A comparing of ion mobility spectra of non-polar hydrocarbons for photoionization, corona discharge ionization and 63 Ni ionization, had carried in. In our work we have investigated four types of IMS spectrometers whose use different sources for molecules under analysis ionization. They use radioactive ionization, ultraviolet photoionization, laser ionization, and roentgen ionization. The traditional explosives had investigated in experiments. In electricity, a corona discharge is an electrical discharge brought on by the ionization of a fluid surrounding a conductor, which occurs when the potential gradient (the strength of the electric field) exceeds a certain value, but conditions are insufficient to cause complete electrical breakdown or arcing.

  13. Limpieza de patrones φ,q,n de descargas parciales; Denoising of partial discharge φ,q,n patterns

    Directory of Open Access Journals (Sweden)

    Santiago Alfredo Dorrbercker Drake

    2015-04-01

    Full Text Available La medición de descargas parciales (DP se sustenta en la detección y filtraje de pulsos de corriente que aparecen en una banda de frecuencia que abarca desde los kilohertzios hasta los gigahertzios, por tal motivo los detectores de descargas parciales (DDP poseen sistemas para desagregar dichos pulsos de corriente. Sin embargo, los DDP también permiten el paso de otras señales de alta frecuencia (ruidos que se mezclan con los pulsos de DP y afectan la medición, interpretación y caracterización de las DP. Para atenuar ese efecto, se han desarrollado distintas técnicas para separar los ruidos tanto asociados a las señales como los existentes en los patrones φ,q,n.  En este artículo se presentan los resultados obtenidos en la reducción de los ruidos asociados a la conmutación de tiristores y los ruidos esporádicos, de los patrones φ,q,n mediante el empleo de técnicas de procesamiento de imágenes digitales. The measurement of partial (PD discharges is sustained in the detection and filtration of current pulses which appear in a band of frequency that include from the kilohertz until the gigahertzios, for such a reason the detectors of partial (PDD discharges they possess systems for the separation of this current pulses. However, PDD also allows the step of other signals of high frequency, denominated noises, that mix with the pulses of PD and they affect measurement, interpretation and characterization of PD. To attenuate that effect, different techniques have been developed to separate the noises so much associated to the signs like the existent ones in the φ,q,n patterns. In this paper are presented the results obtained in the noise reduction of the noises associated to the thyristor’s commutation and the sporadic noises, in the φ,q,n patterns by means of the technical of digital images processing

  14. Development of a positive column pulsed capillary discharge source for use with high resolution Fourier transform spectrometer

    International Nuclear Information System (INIS)

    Syed, W A A

    2002-01-01

    We report the designing and application of a positive column pulsed capillary discharge with the Fourier transform spectrometer (FTS). The pulsed light source has been used for the first time with the ultraviolet FTS. The experiment has been carried out with the high energy pulsed discharge with energy of 2-3 J lasting about 300 ns. A system has been developed to trigger the discharge at about 600 Hz with the pulses directly taken from the FTS sampling system. The spectrum of Ar III has been recorded in the 19 000-50 000 cm -1 region with good signal to noise ratio. The results have opened a wide range of applications in spectroscopy of multiply ionized species

  15. Modeling of magnetically enhanced capacitively coupled plasma sources: Ar discharges

    International Nuclear Information System (INIS)

    Kushner, Mark J.

    2003-01-01

    Magnetically enhanced capacitively coupled plasma sources use transverse static magnetic fields to modify the performance of low pressure radio frequency discharges. Magnetically enhanced reactive ion etching (MERIE) sources typically use magnetic fields of tens to hundreds of Gauss parallel to the substrate to increase the plasma density at a given pressure or to lower the operating pressure. In this article results from a two-dimensional hybrid-fluid computational investigation of MERIE reactors with plasmas sustained in argon are discussed for an industrially relevant geometry. The reduction in electron cross field mobility as the magnetic field increases produces a systematic decrease in the dc bias (becoming more positive). This decrease is accompanied by a decrease in the energy and increase in angular spread of the ion flux to the substrate. Similar trends are observed when decreasing pressure for a constant magnetic field. Although for constant power the magnitudes of ion fluxes to the substrate increase with moderate magnetic fields, the fluxes decreased at larger magnetic fields. These trends are due, in part, to a reduction in the contributions of more efficient multistep ionization

  16. Ozone Production With Dielectric Barrier Discharge: Effects of Power Source and Humidity

    KAUST Repository

    Zhang, Xuming

    2016-08-24

    Ozone synthesis in air dielectric barrier discharge (DBD) was studied with an emphasis on the effects of power sources and humidity. Discharge characteristics were investigated to understand the physical properties of plasma and corresponding system performance. It was found that 10-ns pulsed DBD produced a homogeneous discharge mode, while ac DBD yielded an inhomogeneous pattern with many microdischarge channels. At a similar level of the energy density (ED), decreasing the flowrate is more effective in the production of ozone for the cases of the ac DBD, while increased voltage is more effective for the pulsed DBD. Note that the maximum ozone production efficiency (110 g/kWh) was achieved with the pulsed DBD. At the ED of ∼ 85 J/L, the ozone concentrations with dry air were over three times higher than those with the relative humidity of 100% for both the ac DBD and pulsed DBD cases. A numerical simulation was conducted using a global model to understand a detailed chemical role of water vapor to ozone production. It was found HO and OH radicals from water vapor significantly consumed O atoms, resulting in a reduction in ozone production. The global model qualitatively captured the experimental trends, providing further evidence that the primary effect of humidity on ozone production is chemical in nature.

  17. Medium pressure mercury discharge for use as an intense white light source

    International Nuclear Information System (INIS)

    Kitsinelis, S; Devonshire, R; Stone, D A; Tozer, R C

    2005-01-01

    In this paper, we demonstrate the possibilities that exist in developing a high brightness white light source. The lamp employs mercury at a few Torr and is operated with short pulses of the order of 1 μs at a frequency of 10 kHz. The emission spectrum is atomic in nature and the white light is the outcome of a relative enhancement of the mercury yellow lines at 577 and 579 nm with respect to the rest of the visible lines, which shifts the colour coordinates of the source towards the black body locus of the chromaticity diagram. The pulse operation of a lamp containing mercury at a vapour pressure of 20 Torr offers a greater near-UV and visible output compared to a phosphor-uncoated, low-pressure pulsed compact mercury discharge

  18. Quasi-homogeneous partial coherent source modeling of multimode optical fiber output using the elementary source method

    Science.gov (United States)

    Fathy, Alaa; Sabry, Yasser M.; Khalil, Diaa A.

    2017-10-01

    Multimode fibers (MMF) have many applications in illumination, spectroscopy, sensing and even in optical communication systems. In this work, we present a model for the MMF output field assuming the fiber end as a quasi-homogenous source. The fiber end is modeled by a group of partially coherent elementary sources, spatially shifted and uncorrelated with each other. The elementary source distribution is derived from the far field intensity measurement, while the weighting function of the sources is derived from the fiber end intensity measurement. The model is compared with practical measurements for fibers with different core/cladding diameters at different propagation distances and for different input excitations: laser, white light and LED. The obtained results show normalized root mean square error less than 8% in the intensity profile in most cases, even when the fiber end surface is not perfectly cleaved. Also, the comparison with the Gaussian-Schell model results shows a better agreement with the measurement. In addition, the complex degree of coherence, derived from the model results, is compared with the theoretical predictions of the modified Van Zernike equation showing very good agreement, which strongly supports the assumption that the large core MMF could be considered as a quasi-homogenous source.

  19. Determination of trace amounts of impurities in molybdenum by spark source and glow discharge mass spectrometry

    International Nuclear Information System (INIS)

    Saito, Morimasa

    1994-01-01

    For the determination of trace and ultra-trace amounts of impurities in high-purity molybdenum, spark source mass spectrometry and glow discharge mass spectrometry were studied. In spark source mass spectrometry using the metal probe method, the liquid-helium cryogenic pump was used in order to protect the surface of the samples from oxidation. The theoretical relative sensitivity factors (Mo=1) calculated from physical properties were used. The analytical results obtained for molybdenum tablet and high-purity molybdenum were in good agreement with those obtained by other methods (atomic absorption spectrometry and others). In glow discharge mass spectrometry, the relative sensitivity factors were calculated by using the results obtained by spark source mass spectrometry and atomic absorption spectrometry, and this method was applied to the determination of ultra-trace amounts of impurities in ultra high-purity molybdenum and gave the satisfactory results. The detection limits (2σ, n=10) in the integration time of 600 s for U and Th were 0.6 ppb and 0.3 ppb, and the values for Al, Si, Cr, Mn and Cu were in the range of 10 ppb to 0.5 ppb. (author)

  20. Computational physics of electric discharges in gas flows

    CERN Document Server

    Surzhikov, Sergey T

    2012-01-01

    Gas discharges are of interest for many processes in mechanics, manufacturing, materials science and aerophysics. To understand the physics behind the phenomena is of key importance for the effective use and development of gas discharge devices. This worktreats methods of computational modeling of electrodischarge processes and dynamics of partially ionized gases. These methods are necessary to tackleproblems of physical mechanics, physics of gas discharges and aerophysics.Particular attention is given to a solution of two-dimensional problems of physical mechanics of glow discharges.The use o

  1. Discharge characteristics in inhomogeneous fields under air flow

    DEFF Research Database (Denmark)

    Vogel, Stephan; Holbøll, Joachim

    2017-01-01

    the frequency and magnitude of partial discharges in the vicinity of the electrode due to an increased rate of space charge removal around the tip of the needle and in the gap. The positive polarity shows higher dependency on air flow compared to the negative polarity. It is shown that positive breakdown......This research investigates the impact of high velocity air flow on Partial Discharge (PD) patterns generated in strongly inhomogeneous fields. In the laboratory, a needle plane electrode configuration was exposed to a high electrical DC-field and a laminar air flow up to 22 ms. The needle...

  2. Study of the Dissociative Processes in O_2 Discharges. Development of an Atomic Oxygen Beam Source

    International Nuclear Information System (INIS)

    Pagnon, Daniel

    1992-01-01

    The first part of this work is devoted to the study of dissociative processes in an oxygen glow discharge at low pressure (0,1-5 Torr, 1-80 mA). The kinetics of oxygen atoms has been determined supported by the measurements of atomic concentrations by VUV absorption spectroscopy and actinometry. The reaction coefficients for dissociative excitation and direct excitation of oxygen atoms have been calculated using the cross sections of the literature and a previously calculated EEDF. It has been demonstrated that dissociative excitation is negligible in respect with direct excitation for dissociation rates smaller than 2,5 %. An upper limit of 20 % for dissociative rates is observed. This limit has been explained by the increase of the atomic recombination at the discharge wall with increasing wall temperature. Using all these results, we have designed and optimized a source of oxygen atoms which has then been adapted on a MBE device. The spatial distribution of the atomic density has been measured in molecular jet by laser induced fluorescence (LIF) and Resonant Multi-Photon Ionization (RMPI). A stimulated emission has been evidenced and the coefficient for this process evaluated. A model for the effusion of atoms has been developed from which the flow of atoms on the sample can be predicted. This source has already been used in industrial MBE devices for in-situ oxidation of copper films, superconductors, and substrates for VLSI high speed applications. The methodology of this work and the diagnostics developed can be applied to other kinds of discharges, of other molecular gases, to design sources of atoms for the treatment of large area samples. (author) [fr

  3. Structural, mechanical, electrical and wetting properties of ZrNx films deposited by Ar/N2 vacuum arc discharge: Effect of nitrogen partial pressure

    Science.gov (United States)

    Abdallah, B.; Naddaf, M.; A-Kharroub, M.

    2013-03-01

    Non-stiochiometric zirconium nitride (ZrNx) thin films have been deposited on silicon substrates by vacuum arc discharge of (N2 + Ar) gas mixtures at different N2 partial pressure ratio. The microstructure, mechanical, electrical and wetting properties of these films are studied by means of X-ray diffraction (XRD), micro-Raman spectroscopy, Rutherford back scattering (RBS) technique, conventional micro-hardness testing, electrical resistivity, atomic force microscopy (AFM) and contact angle (CA) measurements. RBS results and analysis show that the (N/Zr) ratio in the film increases with increasing the N2 partial pressure. A ZrNx film with (Zr/N) ratio in the vicinity of stoichiometric ZrN is obtained at N2 partial pressure of 10%. XRD and Raman results indicate that all deposited films have strained cubic crystal phase of ZrN, regardless of the N2 partial pressure. On increasing the N2 partial pressure, the relative intensity of (1 1 1) orientation with respect to (2 0 0) orientation is seen to decrease. The effect of N2 partial pressure on micro-hardness and the resistivity of the deposited film is revealed and correlated to the alteration of grain size, crystallographic texture, stoichiometry and residual stress developed in the film. In particular, it is found that residual stress and nitrogen incorporation in the film play crucial role in the alteration of micro-hardness and resistivity respectively. In addition, CA and AFM results demonstrate that as N2 partial pressure increases, both the surface hydrophobicity and roughness of the deposited film increase, leading to a significant decrease in the film surface free energy (SFE).

  4. Partial differential equation-based localization of a monopole source from a circular array.

    Science.gov (United States)

    Ando, Shigeru; Nara, Takaaki; Levy, Tsukassa

    2013-10-01

    Wave source localization from a sensor array has long been the most active research topics in both theory and application. In this paper, an explicit and time-domain inversion method for the direction and distance of a monopole source from a circular array is proposed. The approach is based on a mathematical technique, the weighted integral method, for signal/source parameter estimation. It begins with an exact form of the source-constraint partial differential equation that describes the unilateral propagation of wide-band waves from a single source, and leads to exact algebraic equations that include circular Fourier coefficients (phase mode measurements) as their coefficients. From them, nearly closed-form, single-shot and multishot algorithms are obtained that is suitable for use with band-pass/differential filter banks. Numerical evaluation and several experimental results obtained using a 16-element circular microphone array are presented to verify the validity of the proposed method.

  5. Application of MEVVA discharge to material surface modification

    International Nuclear Information System (INIS)

    Gao Yu; Geng Man; Huang Yuming; Gong Xiaorong; Yu Yijun; Tang Deli; Tie Jun

    1996-01-01

    The authors describes some characteristics of the MEVVA discharge, the process of generating a cathode-arc plasma and the advantages of the MEVVA discharge compared with the kind of heating-vaporizing-ionizing source. Some practical parameters and the operating process of the MEVVA ion source as well as a plasma source with MEVVA discharge used in a PSII device are presented. Various plasmas having good-quality and high-performance are obtained with MEVVA discharges and have been widely used in sight-line processing and omnibearing ion implantation for material surface modification

  6. Travelling-wave-sustained discharges

    International Nuclear Information System (INIS)

    Schlueter, Hans; Shivarova, Antonia

    2007-01-01

    This review is on discharges maintained by travelling waves: new plasma sources, discovered in 1974 and considered as a prototype of the gas discharges according to their definition as nonlinear systems which unify in a self-consistent manner plasmas and fields. In the presentation here of the fluid-plasma models of the diffusion-controlled regime of the travelling-wave-sustained discharges (TWSDs), the basic features of the discharge maintenance-the discharge self-consistency and the electron heating in the high-frequency field-are stressed. Operation of stationary and pulsed discharges, discharge maintenance without and in external magnetic fields as well as discharge production in different gases (argon, helium, helium-argon gas mixtures and hydrogen) are covered. Modulation instability of diffusion-controlled discharges and discharge filamentation at higher gas pressures are also included in the review. Experimental findings which motivate aspects of the reported modelling are pointed out

  7. Influence of N2 partial pressure on structural and microhardness properties of TiN/ZrN multilayers deposited by Ar/N2 vacuum arc discharge

    Science.gov (United States)

    Naddaf, M.; Abdallah, B.; Ahmad, M.; A-Kharroub, M.

    2016-08-01

    The influence of N2 partial pressure on structural, mechanical and wetting properties of multilayered TiN/ZrN thin films deposited on silicon substrates by vacuum arc discharge of (N2 + Ar) gas mixtures is investigated. X-ray diffraction (XRD) results show that the average texturing coefficient of (1 1 1) orientation and the grain size of both TiN and ZrN individual layers increase with increasing the N2 partial pressure. The Rutherford back scattering (RBS) measurements and analysis reveal that incorporation of the nitrogen in the film increases with increasing the N2 partial pressure and both TiN and ZrN individual layers have a nitrogen over-stoichiometry for N2 partial pressure ⩾50%. The change in the film micro-hardness is correlated to the changes in crystallographic texture, grain size, stoichiometry and the residual stress in the film as a function of the N2 partial pressure. In particular, stoichiometry of ZrN and TiN individual is found to play the vital role in determining the multilayer hardness. The multilayer film deposited at N2 partial pressure of 25% has the best stoichiometric ratio of both TiN and ZrN layers and the highest micro-hardness of about 32 GPa. In addition, water contact angle (WCA) measurements and analysis show a decrease in the work of adhesion on increasing the N2 partial pressure.

  8. Influence of N_2 partial pressure on structural and microhardness properties of TiN/ZrN multilayers deposited by Ar/N_2 vacuum arc discharge

    International Nuclear Information System (INIS)

    Naddaf, M.; Abdallah, B.; Ahmad, M.; A-Kharroub, M.

    2016-01-01

    The influence of N_2 partial pressure on structural, mechanical and wetting properties of multilayered TiN/ZrN thin films deposited on silicon substrates by vacuum arc discharge of (N_2 + Ar) gas mixtures is investigated. X-ray diffraction (XRD) results show that the average texturing coefficient of (1 1 1) orientation and the grain size of both TiN and ZrN individual layers increase with increasing the N_2 partial pressure. The Rutherford back scattering (RBS) measurements and analysis reveal that incorporation of the nitrogen in the film increases with increasing the N_2 partial pressure and both TiN and ZrN individual layers have a nitrogen over-stoichiometry for N_2 partial pressure ⩾50%. The change in the film micro-hardness is correlated to the changes in crystallographic texture, grain size, stoichiometry and the residual stress in the film as a function of the N_2 partial pressure. In particular, stoichiometry of ZrN and TiN individual is found to play the vital role in determining the multilayer hardness. The multilayer film deposited at N_2 partial pressure of 25% has the best stoichiometric ratio of both TiN and ZrN layers and the highest micro-hardness of about 32 GPa. In addition, water contact angle (WCA) measurements and analysis show a decrease in the work of adhesion on increasing the N_2 partial pressure.

  9. Influences of Traction Load Shock on Artificial Partial Discharge Faults within Traction Transformer—Experimental Test for Pattern Recognition

    Directory of Open Access Journals (Sweden)

    Shuaibing Li

    2017-10-01

    Full Text Available Partial discharge (PD measurement and its pattern recognition are vital to fault diagnosis of transformers, especially to those traction substation transformers undergoing repetitive traction load shocks. This paper presents the primary factors induced by traction load shocks including high total harmonics distortion (THD, transient voltage impulse and high-temperature rise, and their effects on the feature parameters of PD. Experimental tests are conducted on six artificial PD models with these factors introduced one by one. Results reveal that the maximum PD quantity and the PD repetitive rate are favorable to be enlarged when the oil temperature exceeds 80 °C or the THD is higher than 16% with certain orders of harmonic. The decline in PD inception voltage can mainly be attributed to the transient voltage impulse. The variation in central frequency of the fast Fourier transformation (FFT spectra transformed from ultra-high frequency signals can mainly be attributed to high THD, especially when it exceeds 20%. The temperature rise has no significant influence on the FFT spectra; the transient voltage impulse, however, can result in a central frequency shift of the floating particle discharge. With the rapid development of high-speed railways, the study presented in this paper will be helpful for field PD detection and recognition of traction substation transformers in the future.

  10. A Simple Analytical Model for Predicting the Detectable Ion Current in Ion Mobility Spectrometry Using Corona Discharge Ionization Sources

    Science.gov (United States)

    Kirk, Ansgar Thomas; Kobelt, Tim; Spehlbrink, Hauke; Zimmermann, Stefan

    2018-05-01

    Corona discharge ionization sources are often used in ion mobility spectrometers (IMS) when a non-radioactive ion source with high ion currents is required. Typically, the corona discharge is followed by a reaction region where analyte ions are formed from the reactant ions. In this work, we present a simple yet sufficiently accurate model for predicting the ion current available at the end of this reaction region when operating at reduced pressure as in High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) or most IMS-MS instruments. It yields excellent qualitative agreement with measurement results and is even able to calculate the ion current within an error of 15%. Additional interesting findings of this model are the ion current at the end of the reaction region being independent from the ion current generated by the corona discharge and the ion current in High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) growing quadratically when scaling down the length of the reaction region. [Figure not available: see fulltext.

  11. On the Use of Monopole Antennas for Determining the Effect of the Enclosure of a Power Transformer Tank in Partial Discharges Electromagnetic Propagation.

    Science.gov (United States)

    Albarracín, Ricardo; Ardila-Rey, Jorge Alfredo; Mas'ud, Abdullahi Abubakar

    2016-01-25

    A well-defined condition-monitoring for power transformers is key to implementing a correct condition-based maintenance (CBM). In this regard, partial discharges (PD) measurement and its analysis allows to carry out on-line maintenance following the standards IEC-60270 and IEC-60076. However, new PD measurements techniques, such as acoustics or electromagnetic (EM) acquisitions using ultra-high-frequency (UHF) sensors are being taken into account, IEC-62478. PD measurements with antennas and the effect of their EM propagation in power transformer tanks is an open research topic that is considered in this paper. In this sense, an empty tank model is studied as a rectangular cavity and their resonances are calculated and compared with their measurement with a network analyser. Besides, two low cost improved monopole antennas deployed inside and outside of the tank model capture background noise and PD pulses in three different test objects (Nomex, twisted pair and insulator). The average spectrum of them are compared and can be found that mainly, the antenna frequency response, the frequency content distribution depending on the PD source and the enclosure resonances modes are the main factors to be considered in PD acquisitions with these sensors. Finally, with this set-up, it is possible to measure PD activity inside the tank from outside.

  12. Evaluation of a new dielectric barrier discharge excitation source for the determination of arsenic with atomic emission spectrometry.

    Science.gov (United States)

    Zhu, Zhenli; He, Haiyang; He, Dong; Zheng, Hongtao; Zhang, Caixiang; Hu, Shenghong

    2014-05-01

    A low power dielectric barrier discharge excitation source was developed to determine arsenic in a cost-effective manner. Arsenic in water was reduced to AsH₃ by hydride generation (HG), which was transported to the miniature dielectric barrier discharge (DBD) excitation source for excitation and optical detection at As 193.7 nm atomic line. The DBD source consists of a quartz tube, a tungsten rod electrode, and a copper coil electrode. The main operation parameters and the potential interferences affecting the determination were investigated. The detection limit for arsenic with the proposed DBD-AES was 4.8 μg L(-1) when the HG products were dried with concentrated H₂SO₄ before introducing to DBD. Repeatability, expressed as the relative standard deviation of the spectral peak height, was 2.8% (n=11) for 0.1 mg L(-1) arsenic solution. The proposed method was successfully applied to the determinations of certified reference material (GBW08605) and nature water samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Rotating dust ring in an RF discharge coupled with a dc-magnetron sputter source. Experiment and simulation

    International Nuclear Information System (INIS)

    Matyash, K; Froehlich, M; Kersten, H; Thieme, G; Schneider, R; Hannemann, M; Hippler, R

    2004-01-01

    During an experiment involving coating of dust grains trapped in an RF discharge using a sputtering dc-magnetron source, a rotating dust ring was observed and investigated. After the magnetron was switched on, the dust cloud levitating above the RF electrode formed a ring rotating as a rigid body. Langmuir probe diagnostics were used for the measurement of plasma density and potential. It was discovered that the coupling of the dc-magnetron source to the RF discharge causes steep radial gradients in electron density and plasma potential. The rotation of the dust ring is attributed to the azimuthal component of the ion drag force, which appears due to the azimuthal drift of the ions caused by crossed radial electric and axial magnetic fields. In order to get more insight into the mechanism of dust ring rotation, a Particle-in-Cell simulation of a rotating dust cloud was performed. The results of the experiment and simulation are presented and discussed

  14. Rotating dust ring in an RF discharge coupled with a dc-magnetron sputter source. Experiment and simulation

    Energy Technology Data Exchange (ETDEWEB)

    Matyash, K [Institut fuer Niedertemperaturplasmaphysik Greifswald, Fr.-L.-Jahn-Strasse 19, 17489 Greifswald (Germany); Froehlich, M [Institut fuer Physik, Ernst-Moritz-Arndt-Universitaet Greifswald, Domstrasse 10a, 17487 Greifswald (Germany); Kersten, H [Institut fuer Niedertemperaturplasmaphysik Greifswald, Fr.-L.-Jahn-Strasse 19, 17489 Greifswald (Germany); Thieme, G [Institut fuer Physik, Ernst-Moritz-Arndt-Universitaet Greifswald, Domstrasse 10a, 17487 Greifswald (Germany); Schneider, R [Max-Planck-Institut fuer Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstrasse 1, 17489 Greifswald (Germany); Hannemann, M [Institut fuer Niedertemperaturplasmaphysik Greifswald, Fr.-L.-Jahn-Strasse 19, 17489 Greifswald (Germany); Hippler, R [Institut fuer Physik, Ernst-Moritz-Arndt-Universitaet Greifswald, Domstrasse 10a, 17487 Greifswald (Germany)

    2004-10-07

    During an experiment involving coating of dust grains trapped in an RF discharge using a sputtering dc-magnetron source, a rotating dust ring was observed and investigated. After the magnetron was switched on, the dust cloud levitating above the RF electrode formed a ring rotating as a rigid body. Langmuir probe diagnostics were used for the measurement of plasma density and potential. It was discovered that the coupling of the dc-magnetron source to the RF discharge causes steep radial gradients in electron density and plasma potential. The rotation of the dust ring is attributed to the azimuthal component of the ion drag force, which appears due to the azimuthal drift of the ions caused by crossed radial electric and axial magnetic fields. In order to get more insight into the mechanism of dust ring rotation, a Particle-in-Cell simulation of a rotating dust cloud was performed. The results of the experiment and simulation are presented and discussed.

  15. Electrodeless discharge lamp is easily started, has high stability

    Science.gov (United States)

    Bell, W. E.; Bloom, A. L.

    1966-01-01

    Electrodeless discharge borosilicate glass lamp is used in various high-resolution optical systems. It is partially charged with krypton, contains small amounts of rubidium, and is enclosed in a hermetically sealed envelope that maintains the lamp at an optimum temperature during discharge. The lamp is quickly started by its excitation coil.

  16. Role of secondary emission on discharge dynamics in an atmospheric pressure dielectric barrier discharge

    Energy Technology Data Exchange (ETDEWEB)

    Tay, W. H.; Kausik, S. S.; Yap, S. L.; Wong, C. S., E-mail: cswong@um.edu.my [Plasma Technology Research Centre, Department of Physics, Faculty of Science, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2014-04-15

    The discharge dynamics in an atmospheric pressure dielectric barrier discharge (DBD) is studied in a DBD reactor consisting of a pair of stainless steel parallel plate electrodes. The DBD discharge has been generated by a 50 Hz ac high voltage power source. The high-speed intensified charge coupled device camera is used to capture the images of filaments occurring in the discharge gap. It is observed that frequent synchronous breakdown of micro discharges occurs across the discharge gap in the case of negative current pulse. The experimental results reveal that secondary emissions from the dielectric surface play a key role in the synchronous breakdown of plasma filaments.

  17. 基于听觉场景分析的局部放电降噪算法研究%A Study of Ambient Noise Cancellation Algorithm of Partial Discharge Using CASA

    Institute of Scientific and Technical Information of China (English)

    刘闻

    2016-01-01

    In this paper,based on the partial discharge test of the high pressure chamber of the subway,the factory area and other noise environment,the paper proposes a kind of CASA algorithm,which is indepen-dent of the type of noise and the partial discharge noise reduction based on the analysis of the auditory scene.The algorithm uses two channels to col ect the signal energy,the simulation of the test instrument to extract the intensity difference of different channel signals,as a basis to identify the signal and noise.Then,the acoustic masking effect is used to cover the noise,and the enhancement of the partial discharge signal is realized.%该文针对周围为地铁,厂区等噪声环境下的高压室进行超声波局部放电测试,提出一种与噪声的类型无关、基于听觉场景分析的局部放电降噪CASA算法。该算法利用两个通道采集到的信号能量的不同,模拟局放测试仪提取不同信道信号的强度差,以此为依据来辨别信号和噪声。然后利用声学掩蔽效应,对噪声进行掩蔽,实现局部放电信号的增强。

  18. An Intelligent Sensor for the Ultra-High-Frequency Partial Discharge Online Monitoring of Power Transformers

    Directory of Open Access Journals (Sweden)

    Jian Li

    2016-05-01

    Full Text Available Ultra-high-frequency (UHF partial discharge (PD online monitoring is an effective way to inspect potential faults and insulation defects in power transformers. The construction of UHF PD online monitoring system is a challenge because of the high-frequency and wide-frequency band of the UHF PD signal. This paper presents a novel, intelligent sensor for UHF PD online monitoring based on a new method, namely a level scanning method. The intelligent sensor can directly acquire the statistical characteristic quantities and is characterized by low cost, few data to output and transmit, Ethernet functionality, and small size for easy installation. The prototype of an intelligent sensor was made. Actual UHF PD experiments with three typical artificial defect models of power transformers were carried out in a laboratory, and the waveform recording method and intelligent sensor proposed were simultaneously used for UHF PD measurement for comparison. The results show that the proposed intelligent sensor is qualified for the UHF PD online monitoring of power transformers. Additionally, three methods to improve the performance of intelligent sensors were proposed according to the principle of the level scanning method.

  19. GRACE-based estimates of water discharge over the Yellow River basin

    Directory of Open Access Journals (Sweden)

    Qiong Li

    2016-05-01

    Full Text Available As critical component of hydrologic cycle, basin discharge is a key issue for understanding the hydrological and climatologic related to water and energy cycles. Combining GRACE gravity field models with ET from GLDAS models and precipitation from GPCP, discharge of the Yellow River basin are estimated from the water balance equation. While comparing the results with discharge from GLDAS model and in situ measurements, the results reveal that discharge from Mosaic and CLM GLDAS model can partially represent the river discharge and the discharge estimation from water balance equation could reflect the discharge from precipitation over the Yellow River basin.

  20. UHF Signal Processing and Pattern Recognition of Partial Discharge in Gas-Insulated Switchgear Using Chromatic Methodology.

    Science.gov (United States)

    Wang, Xiaohua; Li, Xi; Rong, Mingzhe; Xie, Dingli; Ding, Dan; Wang, Zhixiang

    2017-01-18

    The ultra-high frequency (UHF) method is widely used in insulation condition assessment. However, UHF signal processing algorithms are complicated and the size of the result is large, which hinders extracting features and recognizing partial discharge (PD) patterns. This article investigated the chromatic methodology that is novel in PD detection. The principle of chromatic methodologies in color science are introduced. The chromatic processing represents UHF signals sparsely. The UHF signals obtained from PD experiments were processed using chromatic methodology and characterized by three parameters in chromatic space ( H , L , and S representing dominant wavelength, signal strength, and saturation, respectively). The features of the UHF signals were studied hierarchically. The results showed that the chromatic parameters were consistent with conventional frequency domain parameters. The global chromatic parameters can be used to distinguish UHF signals acquired by different sensors, and they reveal the propagation properties of the UHF signal in the L-shaped gas-insulated switchgear (GIS). Finally, typical PD defect patterns had been recognized by using novel chromatic parameters in an actual GIS tank and good performance of recognition was achieved.

  1. Deactivation of Escherichia coli in a post-discharge chamber coupled to an atmospheric pressure multi-electrode DBD plasma source

    International Nuclear Information System (INIS)

    Pérez-Ruiz, V H; López-Callejas, R; De la Piedad Beneitez, A; Peña-Eguiluz, R; Mercado-Cabrera, A; Muñoz-Castro, A E; Barocio, S R; Valencia-Alvarado, R; Rodríguez-Méndez, B G

    2012-01-01

    Experimental results from applying a room pressure RF multi-electrode DBD plasma source to the inhibition of the population growth of Gram negative Escherichia coli (E. coli) within a post-discharge reactor are reported. The sample to be treated is deposited in the post-discharge chamber at about 50 mm from the plasma source outlet. Thus, the active species generated by the source are conveyed toward the chamber by the working gas flow. The plasma characterization included the measurement of the axial temperature at different distances from the reactor outlet by means of a K-type thermocouple. The resulting 294 K to 322 K temperature interval corresponded to distances between 10 mm to 1 mm respectively. As the material under treatment is placed further away, any thermal damage of the sample by the plasma is prevented. The measurement and optimization of the ozone O 3 concentration has also been carried out, provided that this is an active specie with particularly high germicide power. The effectiveness treatment of the E. coli bacteria growth inhibition by the proposed plasma source reached 99% when a 10 3 CFU/mL concentration on an agar plate had been exposed during ten minutes.

  2. Pulse electrical discharges in water and their applications

    International Nuclear Information System (INIS)

    Sunka, Pavel

    2001-01-01

    Partial electrical discharges in a water solution as a function of conductivity have been studied experimentally. Using needle-plate electrodes it has been demonstrated that the discharge evolves in two phases. During the first streamer-like phase, the discharge propagated with a velocity of 10 6 cm/s, while during the second arc-like phase the length of the discharge remained almost constant although the current still increased. Higher solution conductivity resulted in the generation of shorter channels, in larger discharge current, and in a higher plasma electron density. Degradation of phenol by the discharge has also been demonstrated. A special metallic electrode covered by a thin layer of porous ceramic has been developed and used for generation of a multichannel discharge. At comparable solution conductivity the ceramic-coated electrode produced plasma with very similar parameters as the needle-plate electrode configuration. Generation of strong focused shock waves by the multichannel discharge in a highly conductive solution has also been demonstrated

  3. Instream Biological Assessment of NPDES Point Source Discharges at the Savannah River Site, 2000

    International Nuclear Information System (INIS)

    Specht, W.L.

    2001-01-01

    The Savannah River Site (SRS) currently has 31 NPDES outfalls that have been permitted by the South Carolina Department of Health and Environmental Control (SCDHEC) to discharge to SRS streams and the Savannah River. In order to determine the cumulative impacts of these discharges to the receiving streams, a study plan was developed to perform in-stream assessments of the fish assemblages, macroinvertebrate assemblages, and habitats of the receiving streams. These studies were designed to detect biological impacts due to point source discharges. Sampling was initially conducted between November 1997 and July 1998 and was repeated in the summer and fall of 2000. A total of 18 locations were sampled (Table 1, Figure 1). Sampling locations for fish and macroinvertebrates were generally the same. However, different locations were sampled for fish (Road A-2) and macroinvertebrates (Road C) in the lower portion of Upper Three Runs, to avoid interference with ongoing fisheries studies at Road C. Also, fish were sampled in Fourmile Branch at Road 4 rather than at Road F because the stream at Road F was too narrow and shallow to support many fish. Sampling locations and parameters are detailed in Sections 2 and 3 of this report. In general, sampling locations were selected that would permit comparisons upstream and downstream of NPDES outfalls. In instances where this approach was not feasible because effluents discharge into the headwaters of a stream, appropriate unimpacted reference were used for comparison purposes. This report summarizes the results of the sampling that was conducted in 2000 and also compares these data to the data that were collected in 1997 and 1998

  4. A Bayesian geostatistical approach for evaluating the uncertainty of contaminant mass discharges from point sources

    Science.gov (United States)

    Troldborg, M.; Nowak, W.; Binning, P. J.; Bjerg, P. L.

    2012-12-01

    Estimates of mass discharge (mass/time) are increasingly being used when assessing risks of groundwater contamination and designing remedial systems at contaminated sites. Mass discharge estimates are, however, prone to rather large uncertainties as they integrate uncertain spatial distributions of both concentration and groundwater flow velocities. For risk assessments or any other decisions that are being based on mass discharge estimates, it is essential to address these uncertainties. We present a novel Bayesian geostatistical approach for quantifying the uncertainty of the mass discharge across a multilevel control plane. The method decouples the flow and transport simulation and has the advantage of avoiding the heavy computational burden of three-dimensional numerical flow and transport simulation coupled with geostatistical inversion. It may therefore be of practical relevance to practitioners compared to existing methods that are either too simple or computationally demanding. The method is based on conditional geostatistical simulation and accounts for i) heterogeneity of both the flow field and the concentration distribution through Bayesian geostatistics (including the uncertainty in covariance functions), ii) measurement uncertainty, and iii) uncertain source zone geometry and transport parameters. The method generates multiple equally likely realizations of the spatial flow and concentration distribution, which all honour the measured data at the control plane. The flow realizations are generated by analytical co-simulation of the hydraulic conductivity and the hydraulic gradient across the control plane. These realizations are made consistent with measurements of both hydraulic conductivity and head at the site. An analytical macro-dispersive transport solution is employed to simulate the mean concentration distribution across the control plane, and a geostatistical model of the Box-Cox transformed concentration data is used to simulate observed

  5. Liquid sampling-atmospheric pressure glow discharge as a secondary excitation source: Assessment of plasma characteristics

    International Nuclear Information System (INIS)

    Manard, Benjamin T.; Gonzalez, Jhanis J.; Sarkar, Arnab; Dong, Meirong; Chirinos, Jose; Mao, Xianglei; Russo, Richard E.; Marcus, R. Kenneth

    2014-01-01

    The liquid sampling-atmospheric pressure glow discharge (LS-APGD) has been assessed as a secondary excitation source with a parametric evaluation regarding carrier gas flow rate, applied current, and electrode distance. With this parametric evaluation, plasma optical emission was monitored in order to obtain a fundamental understanding with regards to rotational temperature (T rot ), excitation temperature (T exc ), electron number density (n e ), and plasma robustness. Incentive for these studies is not only for a greater overall fundamental knowledge of the APGD, but also in instrumenting a secondary excitation/ionization source following laser ablation (LA). Rotational temperatures were determined through experimentally fitting of the N 2 and OH molecular emission bands while atomic excitation temperatures were calculated using a Boltzmann distribution of He and Mg atomic lines. The rotational and excitation temperatures were determined to be ∼ 1000 K and ∼ 2700 K respectively. Electron number density was calculated to be on the order of ∼ 3 × 10 15 cm −3 utilizing Stark broadening effects of the Hα line of the Balmer series and a He I transition. In addition, those diagnostics were performed introducing magnesium (by solution feed and laser ablation) into the plasma in order to determine any perturbation under heavy matrix sampling. The so-called plasma robustness factor, derived by monitoring Mg II/Mg I emission ratios, is also employed as a reflection of potential perturbations in microplasma energetics across the various operation conditions and sample loadings. While truly a miniaturized source ( 3 volume), the LS-APGD is shown to be quite robust with plasma characteristics and temperatures being unaffected upon introduction of metal species, whether by liquid or laser ablation sample introduction. - Highlights: • Liquid sampling-atmospheric pressure glow discharge (LS-APGD) • LS-APGD as a secondary excitation source for laser-ablated (LA

  6. Study on pulsed-discharge devices with high current rising rate for point spot short-wavelength source in dense plasma observations

    International Nuclear Information System (INIS)

    Tachinami, Fumitaka; Anzai, Nobuyuki; Sasaki, Toru; Kikuchi, Takashi; Harada, Nob.

    2014-01-01

    A pulsed-power generator with high current rise based on a pulse-forming-network was studied toward generating intense point-spot X-ray source. To obtain the high rate of current rise, we have designed the compact discharge device with low circuit inductance. The results indicate that the inductance of the compact discharge device was dominated by a gap switch inductance. To reduce the gap switch inductance and operation voltage, the feasible gap switch inductance in the vacuum chamber has been estimated by the circuit simulation. The gap switch inductance can be reduced by the lower pressure operation. It means that the designed discharge device achieves the rate of current rise of 10 12 A/s

  7. Use of a discharge in an hollow cathode as neutral atom source for resonant ionization mass spectrometry

    International Nuclear Information System (INIS)

    Berthoud, T.; Briand, A.; Khelifa, N.; Mauchien, P.

    1987-01-01

    The resonance ionization mass spectrometry in our laboratory is aimed at simplification of isotope measurements of elements present in mixtures and at measurement of very small isotopes. An atomization source which produces an atomic beam collimated from a discharge in a hollow cathode has been developed. First results of this spectrometry with an uranium atomic jet are presented [fr

  8. Influence of N{sub 2} partial pressure on structural and microhardness properties of TiN/ZrN multilayers deposited by Ar/N{sub 2} vacuum arc discharge

    Energy Technology Data Exchange (ETDEWEB)

    Naddaf, M., E-mail: ascientific24@aec.org.sy [Department of Molecular Biology and Biotechnology, Atomic Energy Commission of Syria (AECS), P.O. Box 6091, Damascus (Syrian Arab Republic); Abdallah, B. [Department of Physics, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic); Ahmad, M. [IBA Laboratory, Department of Chemistry, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic); A-Kharroub, M. [Department of Physics, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic)

    2016-08-15

    The influence of N{sub 2} partial pressure on structural, mechanical and wetting properties of multilayered TiN/ZrN thin films deposited on silicon substrates by vacuum arc discharge of (N{sub 2} + Ar) gas mixtures is investigated. X-ray diffraction (XRD) results show that the average texturing coefficient of (1 1 1) orientation and the grain size of both TiN and ZrN individual layers increase with increasing the N{sub 2} partial pressure. The Rutherford back scattering (RBS) measurements and analysis reveal that incorporation of the nitrogen in the film increases with increasing the N{sub 2} partial pressure and both TiN and ZrN individual layers have a nitrogen over-stoichiometry for N{sub 2} partial pressure ⩾50%. The change in the film micro-hardness is correlated to the changes in crystallographic texture, grain size, stoichiometry and the residual stress in the film as a function of the N{sub 2} partial pressure. In particular, stoichiometry of ZrN and TiN individual is found to play the vital role in determining the multilayer hardness. The multilayer film deposited at N{sub 2} partial pressure of 25% has the best stoichiometric ratio of both TiN and ZrN layers and the highest micro-hardness of about 32 GPa. In addition, water contact angle (WCA) measurements and analysis show a decrease in the work of adhesion on increasing the N{sub 2} partial pressure.

  9. Self-stabilized discharge filament in plane-parallel barrier discharge configuration: formation, breakdown mechanism, and memory effects

    Science.gov (United States)

    Tschiersch, R.; Nemschokmichal, S.; Bogaczyk, M.; Meichsner, J.

    2017-10-01

    Single self-stabilized discharge filaments were investigated in the plane-parallel electrode configuration. The barrier discharge was operated inside a gap of 3 mm shielded by glass plates to both electrodes, using helium-nitrogen mixtures and a square-wave feeding voltage at a frequency of 2 kHz. The combined application of electrical measurements, ICCD camera imaging, optical emission spectroscopy and surface charge diagnostics via the electro-optic Pockels effect allowed the correlation of the discharge development in the volume and on the dielectric surfaces. The formation criteria and existence regimes were found by systematic variation of the nitrogen admixture to helium, the total pressure and the feeding voltage amplitude. Single self-stabilized discharge filaments can be operated over a wide parameter range, foremost, by significant reduction of the voltage amplitude after the operation in the microdischarge regime. Here, the outstanding importance of the surface charge memory effect on the long-term stability was pointed out by the recalculated spatio-temporally resolved gap voltage. The optical emission revealed discharge characteristics that are partially reminiscent of both the glow-like barrier discharge and the microdischarge regime, such as a Townsend pre-phase, a fast cathode-directed ionization front during the breakdown and radially propagating surface discharges during the afterglow.

  10. Hospitalization for partial nephrectomy was not associated with intrathecal opioid analgesia: Retrospective analysis.

    Science.gov (United States)

    Weingarten, Toby N; Del Mundo, Serena B; Yeoh, Tze Yeng; Scavonetto, Federica; Leibovich, Bradley C; Sprung, Juraj

    2014-10-01

    The aim of this retrospective study is to test the hypothesis that the use of spinal analgesia shortens the length of hospital stay after partial nephrectomy. We reviewed all patients undergoing partial nephrectomy for malignancy through flank incision between January 1, 2008, and June 30, 2011. We excluded patients who underwent tumor thrombectomy, used sustained-release opioids, or had general anesthesia supplemented by epidural analgesia. Patients were grouped into "spinal" (intrathecal opioid injection for postoperative analgesia) versus "general anesthetic" group, and "early" discharge group (within 3 postoperative days) versus "late" group. Association between demographics, patient physical status, anesthetic techniques, and surgical complexity and hospital stay were analyzed using multivariable logistic regression analysis. Of 380 patients, 158 (41.6%) were discharged "early" and 151 (39.7%) were "spinal" cases. Both spinal and early discharge groups had better postoperative pain control and used less postoperative systemic opioids. Spinal analgesia was associated with early hospital discharge, odds ratio 1.52, (95% confidence interval 1.00-2.30), P = 0.05, but in adjusted analysis was no longer associated with early discharge, 1.16 (0.73-1.86), P = 0.52. Early discharge was associated with calendar year, with more recent years being associated with early discharge. Spinal analgesia combined with general anesthesia was associated with improved postoperative pain control during the 1(st) postoperative day, but not with shorter hospital stay following partial nephrectomy. Therefore, unaccounted practice changes that occurred during more recent times affected hospital stay.

  11. Discharge lamp technologies

    Science.gov (United States)

    Dakin, James

    1994-01-01

    This talk is an overview of discharge lamp technology commonly employed in general lighting, with emphasis on issues pertinent to lighting for plant growth. Since the audience is primarily from the plant growth community, and this begins the light source part of the program, we will start with a brief description of the discharge lamps. Challenges of economics and of thermal management make lamp efficiency a prime concern in controlled environment agriculture, so we will emphasize science considerations relating to discharge lamp efficiency. We will then look at the spectra and ratings of some representative lighting products, and conclude with a discussion of technological advances.

  12. Prerequisites for Accurate Monitoring of River Discharge Based on Fixed-Location Velocity Measurements

    Science.gov (United States)

    Kästner, K.; Hoitink, A. J. F.; Torfs, P. J. J. F.; Vermeulen, B.; Ningsih, N. S.; Pramulya, M.

    2018-02-01

    River discharge has to be monitored reliably for effective water management. As river discharge cannot be measured directly, it is usually inferred from the water level. This practice is unreliable at places where the relation between water level and flow velocity is ambiguous. In such a case, the continuous measurement of the flow velocity can improve the discharge prediction. The emergence of horizontal acoustic Doppler current profilers (HADCPs) has made it possible to continuously measure the flow velocity. However, the profiling range of HADCPs is limited, so that a single instrument can only partially cover a wide cross section. The total discharge still has to be determined with a model. While the limitations of rating curves are well understood, there is not yet a comprehensive theory to assess the accuracy of discharge predicted from velocity measurements. Such a theory is necessary to discriminate which factors influence the measurements, and to improve instrument deployment as well as discharge prediction. This paper presents a generic method to assess the uncertainty of discharge predicted from range-limited velocity profiles. The theory shows that a major source of error is the variation of the ratio between the local and cross-section-averaged velocity. This variation is large near the banks, where HADCPs are usually deployed and can limit the advantage gained from the velocity measurement. We apply our theory at two gauging stations situated in the Kapuas River, Indonesia. We find that at one of the two stations the index velocity does not outperform a simple rating curve.

  13. Moisture Migration in an Oil-Paper Insulation System in Relation to Online Partial Discharge Monitoring of Power Transformers

    Directory of Open Access Journals (Sweden)

    Wojciech Sikorski

    2016-12-01

    Full Text Available Most power transformers operating in a power system possess oil-paper insulation. A serious defect of this type of insulation, which is associated with long operation time, is an increase in the moisture content. Moisture introduces a number of threats to proper operation of the transformer, e.g., ignition of partial discharges (PDs. Due to the varying temperature of the insulation system during the unit’s normal operation, a dynamic change (migration of water takes place, precipitating the oil-paper system from a state of hydrodynamic equilibrium. This causes the PDs to be variable in time, and they may intensify or extinguish. Studies on model objects have been conducted to determine the conditions (temperature, humidity, time that will have an impact on the ignition and intensity of the observed phenomenon of PDs. The conclusions of this study will have a practical application in the evaluation of measurements conducted in the field, especially in relation to the registration of an online PD monitoring system.

  14. Xenon capillary discharge as a source of soft X-ray

    Czech Academy of Sciences Publication Activity Database

    Vrba, Pavel; Vrbová, M.

    2002-01-01

    Roč. 52, supplement D (2002), s. 112-116 ISSN 0011-4626. [Symposium on Plasma Physics and Technology/20th./. Prague, 10.06.2002-13.06.2002] Institutional research plan: CEZ:AV0Z2043910 Keywords : capillary discharge, soft X-ray Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.311, year: 2002

  15. Physics of partially ionized plasmas

    CERN Document Server

    Krishan, Vinod

    2016-01-01

    Plasma is one of the four fundamental states of matter; the other three being solid, liquid and gas. Several components, such as molecular clouds, diffuse interstellar gas, the solar atmosphere, the Earth's ionosphere and laboratory plasmas, including fusion plasmas, constitute the partially ionized plasmas. This book discusses different aspects of partially ionized plasmas including multi-fluid description, equilibrium and types of waves. The discussion goes on to cover the reionization phase of the universe, along with a brief description of high discharge plasmas, tokomak plasmas and laser plasmas. Various elastic and inelastic collisions amongst the three particle species are also presented. In addition, the author demonstrates the novelty of partially ionized plasmas using many examples; for instance, in partially ionized plasma the magnetic induction is subjected to the ambipolar diffusion and the Hall effect, as well as the usual resistive dissipation. Also included is an observation of kinematic dynam...

  16. The Effects of Added Hydrogen on Noble Gas Discharges Used as Ambient Desorption/Ionization Sources for Mass Spectrometry

    Science.gov (United States)

    Ellis, Wade C.; Lewis, Charlotte R.; Openshaw, Anna P.; Farnsworth, Paul B.

    2016-09-01

    We demonstrate the effectiveness of using hydrogen-doped argon as the support gas for the dielectric barrier discharge (DBD) ambient desorption/ionization (ADI) source in mass spectrometry. Also, we explore the chemistry responsible for the signal enhancement observed when using both hydrogen-doped argon and hydrogen-doped helium. The hydrogen-doped argon was tested for five analytes representing different classes of molecules. Addition of hydrogen to the argon plasma gas enhanced signals for gas-phase analytes and for analytes coated onto glass slides in positive and negative ion mode. The enhancements ranged from factors of 4 to 5 for gas-phase analytes and factors of 2 to 40 for coated slides. There was no significant increase in the background. The limit of detection for caffeine was lowered by a factor of 79 using H2/Ar and 2 using H2/He. Results are shown that help explain the fundamental differences between the pure-gas discharges and those that are hydrogen-doped for both argon and helium. Experiments with different discharge geometries and grounding schemes indicate that observed signal enhancements are strongly dependent on discharge configuration.

  17. Submarine groundwater discharge as an important nutrient source influencing nutrient structure in coastal water of Daya Bay, China

    Science.gov (United States)

    Wang, Xuejing; Li, Hailong; Zheng, Chunmiao; Yang, Jinzhong; Zhang, Yan; Zhang, Meng; Qi, Zhanhui; Xiao, Kai; Zhang, Xiaolang

    2018-03-01

    As an important nutrient source for coastal waters, submarine groundwater discharge (SGD) has long been largely ignored in Daya Bay, China. In this study, we estimate the fluxes of SGD and associated nutrients into this region using a 224Ra mass balance model and assess the contribution/importance of nutrients by SGD, benthic sediments, local rivers, and atmospheric deposition. The results of 224Ra mass balance show that the estimated SGD ranges from (2.76 ± 1.43) × 106 m3/d to (1.03 ± 0.53) × 107 m3/d with an average of (6.32 ± 2.42) × 106 m3/d, about 16 times the total discharge rate of local rivers. The nutrient loading from SGD is estimated to be (1.05-1.99) × 105 mol/d for NO3-N, (4.04-12.16) × 103 mol/d for DIP, and (3.54-11.35) × 105 mol/d for Si. Among these considered nutrient sources, we find that SGD is the primary source for Si and NO3-N, contributing 68% and 42% of all considered sources, respectively. The atmospheric NO3-N flux is comparable to that from SGD. The local rivers are the most important source for DIP, contributing 75% of all considered sources. SGD with high N:P ratio (NO3-N/DIP) of 37.0 delivers not only a large quantity of nutrients, but also changes nutrient structure in coastal water. Based on a DIP budget, primary productivity is evaluated to be 54-73 mg C/m2 d, in which SGD accounts for approximately 30% of total production. This study indicates that SGD is a key source of nutrients to coastal waters and may cause an obvious change of primary production and nutrient structure in Daya Bay.

  18. Detection of partial discharges in oil transformers with the aid of acoustic emission analysis; Detektion von Teilentladungen in Oeltransformatoren durch die Schallemissionsanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Loehr, M. [Physical Acoustics BV - Deutschland, Hamburg (Germany)

    2007-07-01

    Since the early eighties, acoustic emission analysis has been used for functional testing of transformers. Partial discharges of 150 pC and above are detected reliably. Transformers with oil/paper insulation as a rule are inspected during operation by analysis of the transformer oil at regular intervals or continuously. This integral method provides no information on the operating conditions causing partial discharge and no information on their location. This information gap may be closed by acoustic emission analysis, which will provide the key information required for selective planning of preventive measures. Physical Acoustics (PAC) tested several hundreds of transformers successfully for their operating performance (see also EPRI Project I.D. No. 051481). As a result, e.g., transformers can now be operated for a longer period of time below critical load. [German] Die Schallemissionsanalyse wird seit den fruehen 80-iger Jahren letzten Jahrhunderts von Transformator-Herstellern bei der Funktionspruefung eingesetzt. Hierbei werden Teilentladungen von 150 pC und mehr zuverlaessig detektiert. Oel-papierisolierte Transformatoren werden in der Regel waehrend des Betriebs durch eine Analyse des Transformator-Oels inspeziert. Die Oelanalyse kann in regelmaessigen Abstaenden oder dauerhaft erfolgen. Als integrales Verfahren bietet diese Methode keine Information zu den Betriebsbedingungen unter den Teilentladungen auftreten und gibt auch keine Information zum Ort deren Auftretens. Diese Informationsluecke kann durch den Einsatz einer Schallemissionspruefung (AT) geschlossen werden. Mit dem Messen der Schallemission durch am Trafokessel angebrachte Sensoren kann der Ort und der Zeitpunkt von Stoerungen festgestellt werden. Mit diesen Schluesselinformationen wird es moeglich, die weiteren notwendigen Massnahmen gezielt zu planen. Physical Acoustics (PAC) hat mehrere hunderte von Transformatoren erfolgreich auf ihr Betriebsverhalten untersucht (siehe auch EPRI-Projekt I

  19. Characterization of polarized electrons coming from helium post-discharge source

    International Nuclear Information System (INIS)

    Zerhouni, R.O.

    1996-02-01

    The objective of this thesis is the characterization of the polarized electron source developed at Orsay and foreseen to be coupled to a cw accelerator for nuclear physics experiments. The principle of operation of this source relies on the chemo-ionization reaction between optically aligned helium triplet metastable atoms and CO 2 molecules. The helium metastable atoms are generated by injection of purified helium into a 2,45 GHz micro-wave discharge. They are optically pumped using two beams of 1,083 micro-meter resonant radiation, one circularly and the other linearly polarized. Both beams are delivered by a high power LNA laser. The metastable atomic beam interacts with a dense (10 13 cm -3 ) spin singlet CO 2 target. A fraction of the produced polarized electrons is extracted and collimated by electrostatic optics. Either to the Mott polarimeter or to the Faraday cup in order to measure the electron polarization and extracted current. For current intensities of 100 micro-Amperes, the electronic polarization reaches 62 % and shows that this type of source has reached the same high competitive level as the most performing GaAs ones. Additionally, the optical properties of the extracted beam are found to be excellent. These properties (energy spread and emittance) reflect the electron energy distribution at the chemo-ionization region. The upper limit of the beam's energy spread is 0.24 eV since this value characterizes our instrumental resolution. The average normalized emittance is found to be 0.6 pi mm-mrad. These values satisfy the requirements of most cw accelerators. All the measurements were performed at low electron beam transport energies (1 to 2 KeV). (author). 105 refs., 54 figs., 4 tabs

  20. Dielectric barrier discharges applied for soft ionization and their mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, Sebastian; Klute, Felix David; Schütz, Alexander; Franzke, Joachim, E-mail: joachim.franzke@isas.de

    2017-01-25

    Dielectric barrier discharges are used for analytical applications as dissociative source for optical emission spectrometry and for ambient-ionization techniques. In the range of ambient-ionization techniques it has attracted much attention in fields like food safety, biological analysis, mass spectrometry for reaction monitoring and imaging forensic identification. In this review some examples are given for the application as desorption/ionization source as well as for the sole application as ionization source with different sample introductions. It will be shown that the detection might depend on the certain distance of the plasma in reference to the sample or the kind of discharge which might be produced by different shapes of the applied high voltage. Some attempts of characterization are presented. A more detailed characterization of the dielectric barrier discharge realized with two ring electrodes, each separately covered with a dielectric layer, is described. - Highlights: • Dielectric barrier discharge applied as desorption/ionization source. • Dielectric barrier discharge applied solely as ionization source. • Different geometries in order to maintain soft ionization. • Characterization of the LTP probe. • Dielectric barrier discharges with two dielectric barriers (ring-ring shape).

  1. Discharge lamp technologies

    Energy Technology Data Exchange (ETDEWEB)

    Dakin, J. [GE Lighting, Cleveland, OH (United States)

    1994-12-31

    This talk is an overview of discharge lamp technology commonly employed in general lighting, with emphasis on issues pertinent to lighting for plant growth. Since the audience is primarily from the plant growth community, and this begins the light source part of the program, we will start with a brief description of the discharge lamps. Challenges of economics and of thermal management make lamp efficiency a prime concern in controlled environment agriculture, so we will emphasize science considerations relating to discharge lamp efficiency. We will then look at the spectra and ratings of some representative lighting products, and conclude with a discussion of technological advance. A general overview of discharge lighting technology can be found in the book of Waymouth (1971). A recent review of low pressure lighting discharge science is found in Dakin (1991). The pioneering paper of Reiling (1964) provides a good introduction to metal halide discharges. Particularly relevant to lighting for plant growth, a recent and thorough treatment of high pressure Na lamps is found in the book by deGroot and vanVliet (1986). Broad practical aspects of lighting application are thoroughly covered in the IES Lighting Handbook edited by Kaufman (1984).

  2. Development of soft ionization using direct current pulse glow discharge plasma source in mass spectrometry for volatile organic compounds analysis

    Science.gov (United States)

    Nunome, Yoko; Kodama, Kenji; Ueki, Yasuaki; Yoshiie, Ryo; Naruse, Ichiro; Wagatsuma, Kazuaki

    2018-01-01

    This study describes an ionization source for mass analysis, consisting of glow discharge plasma driven by a pulsed direct-current voltage for soft plasma ionization, to detect toxic volatile organic compounds (VOCs) rapidly and easily. The novelty of this work is that a molecular adduct ion, in which the parent molecule attaches with an NO+ radical, [M + NO]+, can be dominantly detected as a base peak with little or no fragmentation of them in an ambient air plasma at a pressure of several kPa. Use of ambient air as the discharge plasma gas is suitable for practical applications. The higher pressure in an ambient air discharge provided a stable glow discharge plasma, contributing to the soft ionization of organic molecules. Typical mass spectra of VOCs toluene, benzene, o-xylene, chlorobenzene and n-hexane were observed as [M + NO]+ adduct ion whose peaks were detected at m/z 122, 108, 136, 142 and 116, respectively. The NO generation was also confirmed by emission bands of NO γ-system. The ionization reactions were suggested, such that NO+ radical formed in an ambient air discharge could attach with the analyte molecule.

  3. Liquid sampling-atmospheric pressure glow discharge as a secondary excitation source: Assessment of plasma characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Manard, Benjamin T. [Department of Chemistry, Clemson University, Clemson, SC 29634 (United States); Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Gonzalez, Jhanis J. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Sarkar, Arnab [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Dong, Meirong; Chirinos, Jose; Mao, Xianglei; Russo, Richard E. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Marcus, R. Kenneth [Department of Chemistry, Clemson University, Clemson, SC 29634 (United States)

    2014-04-01

    The liquid sampling-atmospheric pressure glow discharge (LS-APGD) has been assessed as a secondary excitation source with a parametric evaluation regarding carrier gas flow rate, applied current, and electrode distance. With this parametric evaluation, plasma optical emission was monitored in order to obtain a fundamental understanding with regards to rotational temperature (T{sub rot}), excitation temperature (T{sub exc}), electron number density (n{sub e}), and plasma robustness. Incentive for these studies is not only for a greater overall fundamental knowledge of the APGD, but also in instrumenting a secondary excitation/ionization source following laser ablation (LA). Rotational temperatures were determined through experimentally fitting of the N{sub 2} and OH molecular emission bands while atomic excitation temperatures were calculated using a Boltzmann distribution of He and Mg atomic lines. The rotational and excitation temperatures were determined to be ∼ 1000 K and ∼ 2700 K respectively. Electron number density was calculated to be on the order of ∼ 3 × 10{sup 15} cm{sup −3} utilizing Stark broadening effects of the Hα line of the Balmer series and a He I transition. In addition, those diagnostics were performed introducing magnesium (by solution feed and laser ablation) into the plasma in order to determine any perturbation under heavy matrix sampling. The so-called plasma robustness factor, derived by monitoring Mg II/Mg I emission ratios, is also employed as a reflection of potential perturbations in microplasma energetics across the various operation conditions and sample loadings. While truly a miniaturized source (< 1 mm{sup 3} volume), the LS-APGD is shown to be quite robust with plasma characteristics and temperatures being unaffected upon introduction of metal species, whether by liquid or laser ablation sample introduction. - Highlights: • Liquid sampling-atmospheric pressure glow discharge (LS-APGD) • LS-APGD as a secondary

  4. Comparison between off-resonance and electron Bernstein waves heating regime in a microwave discharge ion source

    Energy Technology Data Exchange (ETDEWEB)

    Castro, G.; Di Giugno, R.; Miracoli, R. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Universita degli Studi di Catania, Dipartimento di Fisica e Astronomia, V. S. Sofia 64, 95123 Catania (Italy); Mascali, D. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); CSFNSM, Viale A. Doria 6, 95125 Catania (Italy); Romano, F. P. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); CNR-IBAM Via Biblioteca 4, 95124 Catania (Italy); Celona, L.; Gammino, S.; Lanaia, D.; Ciavola, G. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Serafino, T. [CSFNSM, Viale A. Doria 6, 95125 Catania (Italy); Di Bartolo, F. [Universita di Messina, Ctr. da Papardo-Sperone, 98100 Messina (Italy); Gambino, N. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Universita degli Studi di Catania, Dipartimento di Fisica e Astronomia, V. S. Sofia 64, 95123 Catania (Italy); IET-Institute of Energy Technology, LEC-Laboratory for Energy Conversion, ETH Zurich, Sonneggstrasse 3, CH-8092 Zurich (Switzerland)

    2012-02-15

    A microwave discharge ion source (MDIS) operating at the Laboratori Nazionali del Sud of INFN, Catania has been used to compare the traditional electron cyclotron resonance (ECR) heating with an innovative mechanisms of plasma ignition based on the electrostatic Bernstein waves (EBW). EBW are obtained via the inner plasma electromagnetic-to-electrostatic wave conversion and they are absorbed by the plasma at cyclotron resonance harmonics. The heating of plasma by means of EBW at particular frequencies enabled us to reach densities much larger than the cutoff ones. Evidences of EBW generation and absorption together with X-ray emissions due to high energy electrons will be shown. A characterization of the discharge heating process in MDISs as a generalization of the ECR heating mechanism by means of ray tracing will be shown in order to highlight the fundamental physical differences between ECR and EBW heating.

  5. Thermal modeling of cylindrical lithium ion battery during discharge cycle

    International Nuclear Information System (INIS)

    Jeon, Dong Hyup; Baek, Seung Man

    2011-01-01

    Highlights: → Transient and thermo-electric finite element analysis (FEA) of cylindrical lithium ion (Li-ion) battery was presented. → This model provides the thermal behavior of Li-ion battery during discharge cycle. → A LiCoO 2 /C battery at various discharge rates was investigated. → The contribution of heat source due to joule heating was significant at a high discharge rate. → The contribution of heat source due to entropy change was dominant at a low discharge rate. - Abstract: Transient and thermo-electric finite element analysis (FEA) of cylindrical lithium ion (Li-ion) battery was presented. The simplified model by adopting a cylindrical coordinate was employed. This model provides the thermal behavior of Li-ion battery during discharge cycle. The mathematical model solves conservation of energy considering heat generations due to both joule heating and entropy change. A LiCoO 2 /C battery at various discharge rates was investigated. The temperature profile from simulation had similar tendency with experiment. The temperature profile was decomposed with contributions of each heat sources and was presented at several discharge rates. It was found that the contribution of heat source due to joule heating was significant at a high discharge rate, whereas that due to entropy change was dominant at a low discharge rate. Also the effect of cooling condition and the LiNiCoMnO 2 /C battery were analyzed for the purpose of temperature reduction.

  6. Recent advances in incoherent light sources in the vacuum-ultraviolet (88-200nm) based on electric discharge plasmas

    International Nuclear Information System (INIS)

    Ward, B.K.; Carman, R.J.; Mildren, R.P.; Kane, D.M.

    2004-01-01

    Full text: Rare-gas and rare gas-halide excimer lamps are powerful, frequency agile, mercury-free sources of high power, narrow band (10nm-30nm), UV and VUV radiation covering the wavelength range 88nm-320nm. A very efficient and practically convenient method of excitation is achieved using the dielectric barrier discharge (DBD). In the DBD, charge build-up on an insulating (dielectric) barrier at one or both of the electrodes provides an intrinsic mechanism for quenching the discharge before the transition to a high current discharge. The UV/VUV output from rare-gas DBD lamps is highly monochromatic, derived predominantly from 2nd excimer continuum, with negligible output at visible and infrared wavelengths. For DBD lamps powered by sinusoidal voltage waveforms (50Hz-100kHz), the electrical to optical conversion efficiency typically reaches 10-20%. The discharge structure consists of multiple transient plasma aments that occur stochastically in time during the discharge cycle leading to VUV output pulses with irregular spacing and amplitude. We have shown, however, that using discrete high-voltage pulses of relatively short duration, produces a short-lived homogeneous discharge that generates much higher peak power from short (sub-microsecond) VUV output pulses, with an additional increase (two- fold) in overall efficiency. Conversion efficiencies between 40-60% have also been reported for short-pulse excitation techniques. Efficient generation of pulsed, high peak-power VUV output is of interest for a broad range of applications in time-resolved spectroscopy, photo-lithography, materials processing and surface modification/cleaning, killing of micro- organisms and bacteria, sterilization, and in ozone production for water purification

  7. Assessment of the discharge regime and water budget of Belo Vrelo (source of the Tolišnica River, central Serbia

    Directory of Open Access Journals (Sweden)

    Čokorilo-Ilić Marina

    2014-01-01

    Full Text Available A sufficiently long spring discharge regime monitoring data set allows for a large number of analyses, to better understand the process of transformation of precipitation into a discharge hydrograph. It is also possible to determine dynamic groundwater volumes in a karst spring catchment area, the water budget equation parameters and the like. It should be noted that a sufficiently long data set is deemed to be a continuous spring discharge time series of more than 30 years. Such time series are rare in Serbia. They are generally much shorter (less than 15 years, and the respective catchment areas therefore fall into the “ungauged” category. In order to extend existing karst spring discharge time series, we developed a model whose outputs, apart from mean monthly spring discharges, include daily real evapotranspiration rates, catchment size and dynamic volume variation during the analytical period. So far the model has solely been used to assess the discharge regime and water budget of karst springs. The present paper aims to demonstrate that the model also yields good results in the case of springs that drain aquifers developed in marbles. Belo Vrelo (“White Spring”, source of the Tolišnica River, which drains marbles and marbleized limestones and dolomites of Čemerno Mountain, was selected for the present case study. [OI-176022

  8. A dynamical regularization algorithm for solving inverse source problems of elliptic partial differential equations

    Science.gov (United States)

    Zhang, Ye; Gong, Rongfang; Cheng, Xiaoliang; Gulliksson, Mårten

    2018-06-01

    This study considers the inverse source problem for elliptic partial differential equations with both Dirichlet and Neumann boundary data. The unknown source term is to be determined by additional boundary conditions. Unlike the existing methods found in the literature, which usually employ the first-order in time gradient-like system (such as the steepest descent methods) for numerically solving the regularized optimization problem with a fixed regularization parameter, we propose a novel method with a second-order in time dissipative gradient-like system and a dynamical selected regularization parameter. A damped symplectic scheme is proposed for the numerical solution. Theoretical analysis is given for both the continuous model and the numerical algorithm. Several numerical examples are provided to show the robustness of the proposed algorithm.

  9. Effect of electric field configuration on streamer and partial discharge phenomena in a hydrocarbon insulating liquid under AC stress

    International Nuclear Information System (INIS)

    Liu, Z; Liu, Q; Wang, Z D

    2016-01-01

    This paper concerns pre-breakdown phenomena, including streamer characteristics from a fundamental perspective and partial discharge (PD) measurements from an industrial perspective, in a hydrocarbon insulating liquid. The aim was to investigate the possible changes of the liquid’s streamer and PD characteristics and their correlations when the uniformity of the AC electric field varies. In the experiments, a plane-to-plane electrode system incorporating a needle protrusion was used in addition to a needle-to-plane electrode system. When the applied electric field became more uniform, fewer radial branches occurred and streamer propagation towards the ground electrode was enhanced. The transition from streamer propagation dominated breakdown in divergent fields to streamer initiation dominated breakdown in uniform fields was evidenced. Relationships between streamer and PD characteristics were established, which were found to be electric field dependent. PD of the same apparent charge would indicate longer streamers if the electric field is more uniform. (paper)

  10. Small surface wave discharge at atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Kiss' ovski, Zh; Kolev, M; Ivanov, A; Lishev, St; Koleva, I, E-mail: kissov@phys.uni-sofia.b [Faculty of Physics, Sofia University, BG-1164 Sofia (Bulgaria)

    2009-09-21

    A small surface wave driven source produces plasma at atmospheric pressure. Microwave power at frequency 2.45 GHz is coupled with the source and a discharge is ignited at power levels below 10 W. The coaxial exciter of the surface waves has a length of 10 mm because its dielectric is a high permittivity discharge tube. The plasma source operates as a plasma jet in the case of plasma columns longer than the tube length. The source maintains stable plasma columns over a wide range of neutral gas flow and applied power in continuous and pulse regimes. An additional advantage of this source is the discharge self-ignition. An electron temperature of T{sub e} {approx} 1.9 eV and a density of n{sub e} {approx} 3.9 x 10{sup 14} cm{sup -3} are estimated by the probe diagnostics method. The emission spectra in the wavelength range 200-1000 nm under different experimental conditions are analysed and they prove the applicability of the source for analytical spectroscopy. The dependences of column length, reflected power and plasma parameters on the gas flow and the input power are discussed. (fast track communication)

  11. A Novel High-Performance Beam-Supported Membrane Structure with Enhanced Design Flexibility for Partial Discharge Detection

    Directory of Open Access Journals (Sweden)

    Chenzhao Fu

    2017-03-01

    Full Text Available A novel beam-supported membrane (BSM structure for the fiber optic extrinsic Fabry-Perot interferometer (EFPI sensors showing an enhanced performance and an improved resistance to the temperature change was proposed for detecting partial discharges (PDs. The fundamental frequency, sensitivity, linear range, and flatness of the BSM structure were investigated by employing the finite element simulations. Compared with the intact membrane (IM structure commonly used by EFPI sensors, BSM structure provides extra geometrical parameters to define the fundamental frequency when the diameter of the whole membrane and its thickness is determined, resulting in an enhanced design flexibility of the sensor structure. According to the simulation results, it is noted that BSM structure not only shows a much higher sensitivity (increased by almost four times for some cases, and a wider working range of fundamental frequency to choose, but also an improved linear range, making the system development much easier. In addition, BSM structure presents a better flatness than its IM counterpart, providing an increased signal-to-noise ratio (SNR. A further improvement of performance is thought to be possible with a step-forward structural optimization. The BSM structure shows a great potential to design the EFPI sensors, as well as others for detecting the acoustic signals.

  12. Partial discharge testing: a progress report. Statistical evaluation of PD data

    International Nuclear Information System (INIS)

    Warren, V.; Allan, J.

    2005-01-01

    It has long been known that comparing the partial discharge results obtained from a single machine is a valuable tool enabling companies to observe the gradual deterioration of a machine stator winding and thus plan appropriate maintenance for the machine. In 1998, at the annual Iris Rotating Machines Conference (IRMC), a paper was presented that compared thousands of PD test results to establish the criteria for comparing results from different machines and the expected PD levels. At subsequent annual Iris conferences, using similar analytical procedures, papers were presented that supported the previous criteria and: in 1999, established sensor location as an additional criterion; in 2000, evaluated the effect of insulation type and age on PD activity; in 2001, evaluated the effect of manufacturer on PD activity; in 2002, evaluated the effect of operating pressure for hydrogen-cooled machines; in 2003, evaluated the effect of insulation type and setting Trac alarms; in 2004, re-evaluated the effect of manufacturer on PD activity. Before going further in database analysis procedures, it would be prudent to statistically evaluate the anecdotal evidence observed to date. The goal was to determine which variables of machine conditions greatly influenced the PD results and which didn't. Therefore, this year's paper looks at the impact of operating voltage, machine type and winding type on the test results for air-cooled machines. Because of resource constraints, only data collected through 2003 was used; however, as before, it is still standardized for frequency bandwidth and pruned to include only full-load-hot (FLH) results collected for one sensor on operating machines. All questionable data, or data from off-line testing or unusual machine conditions was excluded, leaving 6824 results. Calibration of on-line PD test results is impractical; therefore, only results obtained using the same method of data collection and noise separation techniques are compared. For

  13. Investigation of airflow effects on the dielectric barrier discharge with single/double discharge channel arrangement

    Science.gov (United States)

    Fan, Zhihui; Yan, Huijie; Liu, Yidi; Guo, Hongfei; Wang, Yuying; Ren, Chunsheng

    2018-05-01

    Atmospheric-pressure dielectric barrier discharge (DBD) with airflow participation has been widely used in recent years. In this paper, effects of airflow on DBD characteristics are experimentally investigated by single/double pin-to-plate DBD arrangements with an AC exciting source. The discharge electrical characteristics and the movements of discharge channels in airflow are investigated with a single pin electrode arrangement. The current intensities increase in positive cycles and decrease in negative cycles with the increase in airflow velocity. The transition from a filamentary discharge to a diffuse discharge is observed under certain airflow conditions, and the discharge channels move with the airflow with a movement velocity less than the corresponding airflow velocity. In the cases of double pin electrode arrangements, the repulsion between double pin discharge channels is apparent at a 10 mm distance but is not obvious at a 20 mm distance. When the airflow is introduced into the discharge gap, not as in the case of single pin electrode arrangement, the movements of discharge channels in airflow are affected by adjacent discharge channels. The corresponding reasons are analyzed in the paper.

  14. Ultraviolet-B radiation enhancement in dielectric barrier discharge based xenon chloride exciplex source by air

    Energy Technology Data Exchange (ETDEWEB)

    Gulati, P., E-mail: pgulati1512@gmail.com [CSIR-Central Electronics Engineering Research Institute (CSIR-CEERI), Pilani, Rajasthan-333031 (India); Department of Physics, Banasthali University, P.O. Banasthali Vidyapith, Rajasthan 304022 (India); Prakash, R.; Pal, U. N.; Kumar, M. [CSIR-Central Electronics Engineering Research Institute (CSIR-CEERI), Pilani, Rajasthan-333031 (India); Vyas, V. [Department of Physics, Banasthali University, P.O. Banasthali Vidyapith, Rajasthan 304022 (India)

    2014-07-07

    A single barrier dielectric barrier discharge tube of quartz with multi-strip Titanium-Gold (Ti-Au) coatings have been developed and utilized for ultraviolet-B (UV-B) radiation production peaking at wavelength 308 nm. The observed radiation at this wavelength has been examined for the mixtures of the Xenon together with chlorine and air admixtures. The gas mixture composition, chlorine gas content, total gas pressure, and air pressure dependency of the UV intensity, has been analyzed. It is found that the larger concentration of Cl{sub 2} deteriorates the performance of the developed source and around 2% Cl{sub 2} in this source produced optimum results. Furthermore, an addition of air in the xenon and chlorine working gas environment leads to achieve same intensity of UV-B light but at lower working gas pressure where significant amount of gas is air.

  15. Ultraviolet-B radiation enhancement in dielectric barrier discharge based xenon chloride exciplex source by air

    Science.gov (United States)

    Gulati, P.; Prakash, R.; Pal, U. N.; Kumar, M.; Vyas, V.

    2014-07-01

    A single barrier dielectric barrier discharge tube of quartz with multi-strip Titanium-Gold (Ti-Au) coatings have been developed and utilized for ultraviolet-B (UV-B) radiation production peaking at wavelength 308 nm. The observed radiation at this wavelength has been examined for the mixtures of the Xenon together with chlorine and air admixtures. The gas mixture composition, chlorine gas content, total gas pressure, and air pressure dependency of the UV intensity, has been analyzed. It is found that the larger concentration of Cl2 deteriorates the performance of the developed source and around 2% Cl2 in this source produced optimum results. Furthermore, an addition of air in the xenon and chlorine working gas environment leads to achieve same intensity of UV-B light but at lower working gas pressure where significant amount of gas is air.

  16. Partial and specific source memory for faces associated to other- and self-relevant negative contexts.

    Science.gov (United States)

    Bell, Raoul; Giang, Trang; Buchner, Axel

    2012-01-01

    Previous research has shown a source memory advantage for faces presented in negative contexts. As yet it remains unclear whether participants remember the specific type of context in which the faces were presented or whether they can only remember that the face was associated with negative valence. In the present study, participants saw faces together with descriptions of two different types of negative behaviour and neutral behaviour. In Experiment 1, we examined whether the participants were able to discriminate between two types of other-relevant negative context information (cheating and disgusting behaviour) in a source memory test. In Experiment 2, we assessed source memory for other-relevant negative (threatening) context information (other-aggressive behaviour) and self-relevant negative context information (self-aggressive behaviour). A multinomial source memory model was used to separately assess partial source memory for the negative valence of the behaviour and specific source memory for the particular type of negative context the face was associated with. In Experiment 1, source memory was specific for the particular type of negative context presented (i.e., cheating or disgusting behaviour). Experiment 2 showed that source memory for other-relevant negative information was more specific than source memory for self-relevant information. Thus, emotional source memory may vary in specificity depending on the degree to which the negative emotional context is perceived as threatening.

  17. Repetitively pulsed UV radiation source based on a run-away electron preionised diffuse discharge in nitrogen

    Science.gov (United States)

    Baksht, E. Kh; Burachenko, A. G.; Lomaev, M. I.; Panchenko, A. N.; Tarasenko, V. F.

    2015-04-01

    An extended repetitively pulsed source of spontaneous UV radiation is fabricated, which may also be used for producing laser radiation. Voltage pulses with an incident wave amplitude of up to 30 kV, a half-amplitude duration of ~4 ns and a rise time of ~2.5 ns are applied to a gap with a nonuniform electric field. For an excitation region length of 35 cm and a nitrogen pressure of 30 - 760 Torr, a diffusive discharge up to a pulse repetition rate of 2 kHz is produced without using an additional system for gap preionisation. An investigation is made of the plasma of the run-away electron preionised diffuse discharge. Using a CCD camera it is found that the dense diffused plasma fills the gap in a time shorter than 1 ns. X-ray radiation is recorded from behind the foil anode throughout the pressure range under study; a supershort avalanche electron beam is recorded by the collector electrode at pressures below 100 Torr.

  18. Discharge cleaning on KSTAR 1st plasma events

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, J. G.; Wang, J. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, J. S.; Yang, H. L.; Kim, K. P.; Kim, K. M. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2008-10-15

    A discharge cleaning of a vacuum vessel was conducted with a GDC (Glow discharge cleaning) and a ICRF-DC(ICRF assisted discharge cleaning) for the KSTAR first plasma event period. The base pressure of the vessel was kept below 10-7 mbar via a cool down of the cryo-vessel, a 100C baking, and a GDC. (Partial pressure of hydrogen and nitrogen is below 10-8 mbar). The diagnostics for a discharge cleaning is a differential pumped RGA attached to a pumping duct and a cold cathode and a hot cathode gauge attached to the vessel and the pumping duct respectively. To analyze the discharge characteristics, a microwave interferometer, Bremsstahlung, H-alphas and a TV camera were used. Two straps among the four straps of the ICRF antenna are used for the ICRF-DC and ICRF heating experiments. The phase difference between the adjacent straps was 0 degree and the operating frequency was 30-33MHz.

  19. Fast plasma discharge capillary design as a high power throughput soft x-ray emission source.

    Science.gov (United States)

    Wyndham, E S; Favre, M; Valdivia, M P; Valenzuela, J C; Chuaqui, H; Bhuyan, H

    2010-09-01

    We present the experimental details and results from a low energy but high repetition rate compact plasma capillary source for extreme ultraviolet and soft x-ray research and applications. Two lengths of capillary are mounted in two versions of a closely related design. The discharge operates in 1.6 and 3.2 mm inner diameter alumina capillaries of lengths 21 and 36 mm. The use of water both as dielectric and as coolant simplifies the compact low inductance design with nanosecond discharge periods. The stored electrical energy of the discharge is approximately 0.5 J and is provided by directly charging the capacitor plates from an inexpensive insulated-gate bipolar transistor in 1 μs or less. We present characteristic argon spectra from plasma between 30 and 300 Å as well as temporally resolved x-ray energy fluence in discrete bands on axis. The spectra also allow the level of ablated wall material to be gauged and associated with useful capillary lifetime according to the chosen configuration and energy storage. The connection between the electron beams associated with the transient hollow cathode mechanism, soft x-ray output, capillary geometry, and capillary lifetime is reported. The role of these e-beams and the plasma as measured on-axis is discussed. The relation of the electron temperature and the ionization stages observed is discussed in the context of some model results of ionization in a non-Maxwellian plasma.

  20. Investigation on discharge characteristics of a coaxial dielectric barrier discharge reactor driven by AC and ns power sources

    Science.gov (United States)

    Qian, WANG; Feng, LIU; Chuanrun, MIAO; Bing, YAN; Zhi, FANG

    2018-03-01

    A coaxial dielectric barrier discharge (DBD) reactor with double layer dielectric barriers has been developed for exhaust gas treatment and excited either by AC power or nanosecond (ns) pulse to generate atmospheric pressure plasma. The comparative study on the discharge characteristics of the discharge uniformity, power deposition, energy efficiency, and operation temperature between AC and ns pulsed coaxial DBD is carried out in terms of optical and electrical characteristics and operation temperature for optimizing the coaxial DBD reactor performance. The voltages across the air gap and dielectric layer and the conduction and displacement currents are extracted from the applied voltages and measured currents of AC and ns pulsed coaxial DBDs for the calculation of the power depositions and energy efficiencies through an equivalent electrical model. The discharge uniformity and operating temperature of the coaxial DBD reactor are monitored and analyzed by optical images and infrared camera. A heat conduction model is used to calculate the temperature of the internal quartz tube. It is found that the ns pulsed coaxial DBD has a much higher instantaneous power deposition in plasma, a lower total power consumption, and a higher energy efficiency compared with that excited by AC power and is more homogeneous and stable. The temperature of the outside wall of the AC and ns pulse excited coaxial DBD reaches 158 °C and 64.3 °C after 900 s operation, respectively. The experimental results on the comparison of the discharge characteristics of coaxial DBDs excited by different powers are significant for understanding of the mechanism of DBDs, reducing energy loss, and optimizing the performance of coaxial DBD in industrial applications.

  1. Development and analytical characterization of a Grimm-type glow discharge ion source operated with high gas flow rates and coupled to a mass spectrometer with high mass resolution

    International Nuclear Information System (INIS)

    Beyer, Claus; Feldmann, Ingo; Gilmour, Dave; Hoffmann, Volker; Jakubowski, Norbert

    2002-01-01

    A Grimm-type glow discharge ion source has been developed and was coupled to a commercial inductively coupled plasma mass spectrometer (ICP-MS) with high mass resolution (Axiom, ThermoElemental, Winsford, UK) by exchanging the front plate of the ICP-MS interface system only. In addition to high discharge powers of up to 70 W, which are typical for a Grimm-type design, this source could be operated with relative high gas flow rates of up to 240 ml min -1 . In combination with a high discharge voltage the signal intensities are reaching a constant level within the first 20 s after the discharge has started. An analytical characterization of this source is given utilizing a calibration using the steel standard reference material NIST 1261A-1265A. The sensitivity for the investigated elements measured with a resolution of 4000 is in the range of 500-6000 cps μg -1 g -1 , and a relative standard deviation (R.S.D.) of the measured isotope relative to Fe of less than 8% for the major and minor components of the sample has been achieved. Limits of detection at ng g -1 levels could be obtained

  2. The effect of an auxiliary discharge on anode sheath potentials in a transverse discharge

    International Nuclear Information System (INIS)

    Foster, J.E.; Gallimore, A.D.

    1997-01-01

    A novel scheme that employs the use of an auxiliary discharge has been shown to reduce markedly anode sheath potentials in a transverse discharge. An 8.8 A low-pressure argon discharge in the presence of a transverse magnetic field was used as the plasma source in this study. In such discharges, the transverse flux that is collected by the anode is severely limited due to marked reductions in the transverse diffusion coefficient. Findings of this study indicate that the local electron number density and the transverse flux increase when the auxiliary discharge is operated. Changes in these parameters are reflected in the measured anode sheath voltage. Anode sheath potentials, estimated by using Langmuir probes, were shown to be reduced by over 33% when the auxiliary discharge is operated. These reductions in anode sheath potentials translated into significant reductions in anode power flux as measured using water calorimeter techniques. The reductions in anode power flux also correlate well with changes in the electron transverse flux. Finally, techniques implementing these positive effects in real plasma accelerators are discussed. copyright 1997 American Institute of Physics

  3. Electrical and spectroscopic characterization of a surgical argon plasma discharge

    International Nuclear Information System (INIS)

    Keller, Sandra; Neugebauer, Alexander; Bibinov, Nikita; Awakowicz, Peter

    2013-01-01

    For electrosurgical procedures, the argon plasma coagulation (APC) discharge is a well-established atmospheric-pressure plasma tool for thermal haemostasis and devitalization of biological tissue. To characterize this plasma source, voltage-current measurements, microphotography, optical emission spectroscopy and numerical simulation are applied. Two discharge modes are established during the operation of the APC plasma source. A short transient spark discharge is ignited within the positive half period of the applied high voltage after a streamer channel connects the APC probe and the counter-electrode. During the second phase, which continues under negative high voltage, a glow discharge is stabilized in the plasma channel.

  4. The diagnostic neutral beam injector with arc-discharge plasma source on the TCV Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Karpushov, Alexander N. [Ecole Polytechnique Federale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas, Association Euratom-Confederation Suisse, CH-1015 Lausanne (Switzerland)], E-mail: alexander.karpushov@epfl.ch; Andrebe, Yanis; Duval, Basil P.; Bortolon, Alessandro [Ecole Polytechnique Federale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas, Association Euratom-Confederation Suisse, CH-1015 Lausanne (Switzerland)

    2009-06-15

    The diagnostic neutral beam injector (DNBI) together with a charge exchange recombination spectroscopy (CXRS) system has been used on the TCV Tokamak as a diagnostic tool for local measurements of plasma ion temperature, velocity and carbon impurity density based on analysis of the beam induced impurity radiation emission since 2000. To improve the performance of the CXRS diagnostic, several upgrades of both the optical system and the neutral beam were performed. An increase of the plasma source size together with beam optimization in 2003 resulted in a twofold increase the beam current. The RF plasma generator was replaced by an arc-discharge plasma source together with a new ion optical system (IOS) in 2006 and subsequent beam optimization is presented herein. This was designed to increase the line brightness of the beam in the CXRS observation region without increasing of the injected power (to avoid plasma perturbation by the beam). The beam characteristics are measured by a multi-chord scanning of Doppler-shifted H{sub {alpha}} emission, thermal measurements on a movable calorimeter and visible optical measurements inside the Tokamak vessel.

  5. Central peaking of magnetized gas discharges

    International Nuclear Information System (INIS)

    Chen, Francis F.; Curreli, Davide

    2013-01-01

    Partially ionized gas discharges used in industry are often driven by radiofrequency (rf) power applied at the periphery of a cylinder. It is found that the plasma density n is usually flat or peaked on axis even if the skin depth of the rf field is thin compared with the chamber radius a. Previous attempts at explaining this did not account for the finite length of the discharge and the boundary conditions at the endplates. A simple 1D model is used to focus on the basic mechanism: the short-circuit effect. It is found that a strong electric field (E-field) scaled to electron temperature T e , drives the ions inward. The resulting density profile is peaked on axis and has a shape independent of pressure or discharge radius. This “universal” profile is not affected by a dc magnetic field (B-field) as long as the ion Larmor radius is larger than a

  6. Study on the Application of an Ultra-High-Frequency Fractal Antenna to Partial Discharge Detection in Switchgears

    Directory of Open Access Journals (Sweden)

    Chenguo Yao

    2013-12-01

    Full Text Available The ultra-high-frequency (UHF method is used to analyze the insulation condition of electric equipment by detecting the UHF electromagnetic (EM waves excited by partial discharge (PD. As part of the UHF detection system, the UHF sensor determines the detection system performance in signal extraction and recognition. In this paper, a UHF antenna sensor with the fractal structure for PD detection in switchgears was designed by means of modeling, simulation and optimization. This sensor, with a flat-plate structure, had two resonance frequencies of 583 MHz and 732 MHz. In the laboratory, four kinds of insulation defect models were positioned in the testing switchgear for typical PD tests. The results show that the sensor could reproduce the electromagnetic waves well. Furthermore, to optimize the installation position of the inner sensor for achieving best detection performance, the precise simulation model of switchgear was developed to study the propagation characteristics of UHF signals in switchgear by finite-difference time-domain (FDTD method. According to the results of simulation and verification test, the sensor should be positioned at the right side of bottom plate in the front cabinet. This research established the foundation for the further study on the application of UHF technique in switchgear PD online detection.

  7. Persulfate injection into a gasoline source zone

    Science.gov (United States)

    Sra, Kanwartej S.; Thomson, Neil R.; Barker, Jim F.

    2013-07-01

    One pore volume of unactivated sodium persulfate was delivered into an emplaced gasoline residual source zone at CFB Borden. Concentrations of inorganic species (S2O82 -, SO42 -, Na+, dissolved inorganic carbon (DIC)) and selected gasoline compounds (benzene, toluene, ethylbenzene, xylenes, trimethylbenzenes and naphthalene) were monitored across a transect equipped with 90 multilevel sampling points for > 10 months post-injection. Mass loading (M˙) of compounds constructed from the transect data was used for assessment purposes. Breakthrough of inorganic species was observed when the injection slug crossed the monitoring transect. An increase in M indicated persulfate consumption during oxidation of gasoline compounds or degradation due to the interaction with aquifer materials. M increased by > 100% suggesting some mineralization of gasoline compounds during treatment. Mass loading for all the monitored gasoline compounds reduced by 46 to 86% as the inorganic slug crossed the monitoring transect. The cumulative mass discharge across the monitoring transect was 19 to 58% lower than that expected without persulfate injection. After the inorganic injection slug was flushed from the source zone a partial rebound (40 to 80% of baseline levels) of mass discharge of the monitored gasoline compounds was observed. The ensemble of data collected provides insight into the fate and transport of the injected persulfate solution, and the accompanying treatment of a gasoline the source zone.

  8. Repetitively pulsed UV radiation source based on a run-away electron preionised diffuse discharge in nitrogen

    Energy Technology Data Exchange (ETDEWEB)

    Baksht, E Kh; Burachenko, A G; Lomaev, M I; Panchenko, A N; Tarasenko, V F [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

    2015-04-30

    An extended repetitively pulsed source of spontaneous UV radiation is fabricated, which may also be used for producing laser radiation. Voltage pulses with an incident wave amplitude of up to 30 kV, a half-amplitude duration of ∼4 ns and a rise time of ∼2.5 ns are applied to a gap with a nonuniform electric field. For an excitation region length of 35 cm and a nitrogen pressure of 30 – 760 Torr, a diffusive discharge up to a pulse repetition rate of 2 kHz is produced without using an additional system for gap preionisation. An investigation is made of the plasma of the run-away electron preionised diffuse discharge. Using a CCD camera it is found that the dense diffused plasma fills the gap in a time shorter than 1 ns. X-ray radiation is recorded from behind the foil anode throughout the pressure range under study; a supershort avalanche electron beam is recorded by the collector electrode at pressures below 100 Torr. (laser applications and other topics in quantum electronics)

  9. An intense lithium ion beam source using vacuum baking and discharge cleaning techniques

    International Nuclear Information System (INIS)

    Moschella, J.J.; Kusse, B.R.; Longfellow, J.P.; Olson, J.C.

    1991-01-01

    We have developed a high-purity, intense, lithium ion beam source which operates at 500 kV and 120 A/cm 2 with pulse widths of 125 ns full width half maximum. The beams were generated using a lithium chloride anode in planar magnetically insulated geometry. We have found that the combination of vacuum baking of the anode at 250 degree C followed by the application of 100 W of pure argon, steady-state, glow discharge cleaning reduced the impurity concentration in the beam to approximately 10% (components other than chlorine or lithium were considered impurities). Although the impurities were low, the concentration of chlorine in the 1+ and 2+ charge states was significant (∼25%). The remaining 65% of the beam consisted of Li + ions. Without the special cleaning process, over half the beam particles were impurities. It was determined that these impurities entered the beam at the anode surface but came originally from material in the vacuum chamber. After the cleaning process, recontamination was observed to occur in approximately 6 min. This long recontamination time, which was much greater than the expected monolayer formation time, was attributed to the elevated temperature of the anode. We also compared the electrical characteristics of the beams produced by LiCl anodes to those generated by a standard polyethylene proton source. In contrast to the polyethylene anode, the LiCl source exhibited a higher impedance, produced beams of lower ion current efficiency and had longer turn on times

  10. Model of discharge lamps with magnetic ballast

    OpenAIRE

    Molina, Julio; Sainz Sapera, Luis; Mesas García, Juan José; Bergas Jané, Joan Gabriel

    2013-01-01

    Magnetic ballast discharge lamp modeling has been extensively studied because these lamps can be an important source of harmonics. Discharge lamp models usually represent the arc voltage by a square waveform. However, this waveform can be far from actual arc voltages, which affects the accuracy of the lamp models. This paper investigates the actual arc voltage behavior of discharge lamps from laboratory measurements and proposes a novel characterization of these voltages to reformulate the co...

  11. Hospital Nurses' and Physicians' Use of Information Sources during their Production of Discharge Summaries: A Cross-Sectional Study

    OpenAIRE

    Hellesø, Ragnhild; Sogstad, Maren Kristine Raknes

    2014-01-01

    Hospital nurses' and physicians' production and exchange of accurate information between levels of care are crucial for ensuring safe and seamless care for patients in transition. We report on a study in which we explored hospital providers' use of information sources when they prepared discharge information for colleges in the community health-care sector. In this cross-sectional study, 510 nurses and 236 physicians responded through a questionnaire. Our findings show that nurses and physici...

  12. An optical sensors for monitoring SF6 dissociation in a corona discharge

    International Nuclear Information System (INIS)

    Irawan, R.; Scelsi, G.B.; Woolsey, G.A.

    1999-01-01

    Sulphur hexafluoride (SF 6 ) is a chemically inert gas (Schumb, 1947) and has high dielectric strength, 3 times greater than air (Morrison and Robins, 1994). In high voltage systems, it is used both as a dielectric and an arc-quenching medium. An electrical breakdown event such as a partial discharge (corona) or arc will dissociate SF 6 into sulphur fluorides, sulphur and fluorine. In a contaminant-free environment, the dissociation products recombine back to SF 6 after extinction of the electrical discharge. Otherwise, some of the products will react with contaminants such as water vapour and oxygen, and with the metal surfaces and electrodes of the discharge chamber, to produce by-products including gaseous sulphur oxyfluorides and solid by-products (Van Brunt, 1985; Griffin et al, 1990 and Vukovic, 1997). As a consequence, a reduction in SF 6 concentration takes place, and the insulating efficiency of the system is degraded. If the SF 6 is not renewed, failure of the high voltage system is likely to eventually occur. One method of monitoring a system is to look for the presence of partial discharges, using techniques such as ultrasonic wave detection (Auckland et al, 1996) or fluorescent plastic fibre (Kurosawa et al., 1997). More directly, the integrity of the SF 6 may be examined using techniques such as mass spectrometry, gas chromatography-mass spectrometry and Fourier Transform Infra-Red Spectroscopy. Such techniques, however, are bulky and require gas samples to be extracted, and so they are unsuited to field use. Since SF 6 insulating systems involve high voltages and a high level of electromagnetic interference, direct in-situ optical monitoring appears to provide the best approach. This paper describes the development of such an optical sensing technique, specifically for continuous monitoring of SF 6 degradation in partial or corona discharges

  13. Experimental study on the impedance of linear discharge R.F. ion sources - modifications on the 'MOAK' type source; Etude experimentale de l'impedance des sources d'ions H. F. a decharge lineaire - modifications au modele de source du types 'MOAK'

    Energy Technology Data Exchange (ETDEWEB)

    Fremiot, Ch [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1962-07-15

    A method of measuring the ion R.F. source impedance is described, and the influence of the working parameters on that impedance is studied. The origin of some working anomalies is deduced with a new coupling method. The gas flow is decreased by modifying the geometry of the discharge vessel. (author) [French] On decrit une methode de mesure de l'impedance d'une source d'ions H.F. et on etudie l'influence des parametres de fonctionnement sur cette Impedance. On en deduit l'origine de quelques anomalies de fonctionnement ainsi qu'une nouvelle methode de couplage. On reduit le debit gazeux en modifiant la geometrie de l'ampoule. (auteur)

  14. Investigation of Combined High-Frequency and Arc Discharges

    International Nuclear Information System (INIS)

    Taran, V.S.; Nezovibatko, Yu.N.; Marinin, V.G.; Shvets, O.M.; Ridozub, V.N.; Gasilin, V.V.

    2001-01-01

    In this paper we analyze experiment with arc and high-frequency (HF) plasma sources carried out in modified devise of the ''Bulat'' type. The HF-sources and combined discharges have attracted considerable attention for surface cleaning and coating. The utilization of such discharges allows decreasing droplet fraction formation and providing better adhesion and microhardness values. The existence of HF-field in plasma allows obtaining either conductive or dielectric coatings and they can be deposited on any substrates. (author)

  15. Single-event burnout hardening of planar power MOSFET with partially widened trench source

    Science.gov (United States)

    Lu, Jiang; Liu, Hainan; Cai, Xiaowu; Luo, Jiajun; Li, Bo; Li, Binhong; Wang, Lixin; Han, Zhengsheng

    2018-03-01

    We present a single-event burnout (SEB) hardened planar power MOSFET with partially widened trench sources by three-dimensional (3D) numerical simulation. The advantage of the proposed structure is that the work of the parasitic bipolar transistor inherited in the power MOSFET is suppressed effectively due to the elimination of the most sensitive region (P-well region below the N+ source). The simulation result shows that the proposed structure can enhance the SEB survivability significantly. The critical value of linear energy transfer (LET), which indicates the maximum deposited energy on the device without SEB behavior, increases from 0.06 to 0.7 pC/μm. The SEB threshold voltage increases to 120 V, which is 80% of the rated breakdown voltage. Meanwhile, the main parameter characteristics of the proposed structure remain similar with those of the conventional planar structure. Therefore, this structure offers a potential optimization path to planar power MOSFET with high SEB survivability for space and atmospheric applications. Project supported by the National Natural Science Foundation of China (Nos. 61404161, 61404068, 61404169).

  16. A current driven capacitively coupled chlorine discharge

    International Nuclear Information System (INIS)

    Huang, Shuo; Gudmundsson, J T

    2014-01-01

    The effect of driving current, driving frequency and secondary electrons on capacitively coupled chlorine discharge is systematically investigated using a hybrid approach consisting of a particle-in-cell/Monte Carlo simulation and a volume-averaged global model. The driving current is varied from 20 to 80 A m −2 , the driving frequency is varied from 13.56 to 60 MHz and the secondary electron emission coefficient is varied from 0.0 to 0.4. Key plasma parameters including electron energy probability function, electron heating rate, ion energy and angular distributions are explored and their variations with control parameters are analyzed and compared with other discharges. Furthermore, we extend our study to dual-frequency (DF) capacitively coupled chlorine discharge by adding a low-frequency current source and explore the effect of the low-frequency source on the discharge. The low-frequency current density is increased from 0 to 4 A m −2 . The flux of Cl 2 + ions to the surface increases only slightly while the average energy of Cl 2 + ions to the surface increases almost linearly with increasing low-frequency current, which shows possible independent control of the flux and energy of Cl 2 + ions by varying the low-frequency current in a DF capacitively coupled chlorine discharge. However, the increase in the flux of Cl + ions with increasing low-frequency current, which is mainly due to the increased dissociation fraction of the background gas caused by extra power supplied by the low-frequency source, is undesirable. (paper)

  17. Long pulse KrCl laser with a high discharge quality

    NARCIS (Netherlands)

    Casper, L.C.; Bastiaens, Hubertus M.J.; Peters, P.J.M.; Boller, Klaus J.; Hofstra, R.M.

    2007-01-01

    The discharge quality and optimum pump parameters of a long-pulse high-pressure gas discharge excited KrCl laser are investigated. A three-electrode prepulse–mainpulse excitation circuit is employed as pump source. The discharge volume contains a gas mixture of HCl/Kr/Ne operated at a total pressure

  18. Acoustic effects of single electrostatic discharges

    International Nuclear Information System (INIS)

    Orzech, Łukasz

    2015-01-01

    Electric discharges, depending on their character, can emit different types of energy, resulting in different effects. Single electrostatic discharges besides generation of electromagnetic pulses are also the source of N acoustic waves. Their specified parameters depending on amount of discharging charge enable determination of value of released charge in a function of acoustic descriptor (e.g. acoustic pressure). Presented approach is the basics of acoustic method for measurement of single electrostatic discharges, enabling direct and contactless measurement of value of charge released during ESD. Method for measurement of acoustic effect of impact of a single electrostatic discharge on the environment in a form of pressure shock wave and examples of acoustic descriptors in a form of equation Q=f(p a ) are described. The properties of measuring system as well as the results of regression static analyses used to determine the described relationships are analysed in details. (paper)

  19. The source of X-rays and high-charged ions based on moderate power vacuum discharge with laser triggering

    Directory of Open Access Journals (Sweden)

    Alkhimova Mariya A.

    2015-06-01

    Full Text Available The source of X-ray radiation with the energy of quanta that may vary in the range hν = 1÷12 keV was developed for studies in X-ray interaction with matter and modification of solid surfaces. It was based on a vacuum spark discharge with the laser triggering. It was shown in our experiments that there is a possibility to adjust X-ray radiation spectrum by changing the configuration of the electrode system when the energy stored in the capacitor is varied within the range of 1÷17 J. A comprehensive study of X-ray imaging and quanta energy was carried out. These experiments were carried out for the case of both direct and reverse polarity of the voltage on the electrodes. Additionally, ion composition of plasma created in a laser-triggered vacuum discharge was analyzed. Highly charged ions Zn(+21, Cu(+20 and Fe(+18 were observed.

  20. Partial discharge patterns and surface deterioration in voids in filled and unfilled epoxy

    DEFF Research Database (Denmark)

    Holbøll, Joachim; Henriksen, Mogens

    1992-01-01

    /height analyses were performed over a period of 2400 h and showed very characteristic discharge patterns for each material combination. A unique behavior with regard to changes of pulse repetition rate and maximum apparent charge was observed for PD in alumina- and silica-filled epoxy. The void surfaces were...

  1. 77 FR 58830 - State Program Requirements; Application To Administer Partial National Pollutant Discharge...

    Science.gov (United States)

    2012-09-24

    .... ODAFF does not have jurisdiction over storm water discharges associated with industrial activity (as defined at 40 CFR 122.26(b)(14)) at facilities whose primary industrial activity is storage of grain, feed... regulated by ODAFF that only incidentally store grain, feed, seed, fertilizer, and agriculture chemicals to...

  2. Is groundwater discharge a significant source of carbon dioxide in North Creek, NSW, Australia?

    Science.gov (United States)

    Atkins, M. L.; Santos, I. R.; Ruiz-Halpern, S.

    2012-12-01

    Dissolved carbon dioxide is enriched in groundwater. However, the contribution of groundwater discharge as a source of CO2 to freshwater ecosystems, estuaries and coastal waters is poorly understood. CO2 evasion from waterbodies has been considered a significant contributor to the global carbon cycle. We assessed for radon (natural groundwater tracer), pCO2 and other parameters in the tidal North Creek in northern NSW, Australia. Once a natural wetland area, the floodplain has been extensively drained for agricultural and residential development. A 16km high resolution spatial survey revealed increasing radon (up to 17.3 dpm L-1) and pCO2 (up to 11151 μatm) concentration in the upstream direction. Allocated 24-h time series experiments were performed at two fixed sites downstream and upstream. Creek water was continuously pumped into a shower head equilibrator. A Licor-7000 and RAD7 monitor were connected in series in a closed air loop system incorporating the showerhead exchanger to measure pCO2 and radon at 10 minute intervals. Under normal hydrological conditions, radon (17.5 - 58.7 dpm L-1) and pCO2 (3031 - 14880 μatm) concentrations were high. Upstream measurements demonstrated a strong correlation between pCO2 and radon (r2 = 0.81, n = 142, p standard deviation and median flux for the three time series deployments were 167 mmol m-2 d-1, 44 mmol m-2 d-1 and 154 mmol m-2 d-1 respectively, rendering this aquatic system a major pathway of CO2 to the atmosphere. Our observations imply that groundwater discharge drove CO2 dynamics at the upstream site while mangrove respiration drove CO2 at the downstream site. Overall, groundwater discharge accounted for at least 32% of surface water in North Creek. Our observations demonstrate that groundwater seepage is an important factor driving CO2 supersaturation in this coastal creek. Groundwater should be accounted for in CO2 budgets in coastal waters.

  3. Photogenic partial seizures.

    Science.gov (United States)

    Hennessy, M J; Binnie, C D

    2000-01-01

    To establish the incidence and symptoms of partial seizures in a cohort of patients investigated on account of known sensitivity to intermittent photic stimulation and/or precipitation of seizures by environmental visual stimuli such as television (TV) screens or computer monitors. We report 43 consecutive patients with epilepsy, who had exhibited a significant EEG photoparoxysmal response or who had seizures precipitated by environmental visual stimuli and underwent detailed assessment of their photosensitivity in the EEG laboratory, during which all were questioned concerning their ictal symptoms. All patients were considered on clinical grounds to have an idiopathic epilepsy syndrome. Twenty-eight (65%) patients reported visually precipitated attacks occurring initially with maintained consciousness, in some instances evolving to a period of confusion or to a secondarily generalized seizure. Visual symptoms were most commonly reported and included positive symptoms such as coloured circles or spots, but also blindness and subjective symptoms such as "eyes going funny." Other symptoms described included nonspecific cephalic sensations, deja-vu, auditory hallucinations, nausea, and vomiting. No patient reported any clear spontaneous partial seizures, and there were no grounds for supposing that any had partial epilepsy excepting the ictal phenomenology of some or all of the visually induced attacks. These findings provide clinical support for the physiological studies that indicate that the trigger mechanism for human photosensitivity involves binocularly innervated cells located in the visual cortex. Thus the visual cortex is the seat of the primary epileptogenic process, and the photically triggered discharges and seizures may be regarded as partial with secondary generalization.

  4. Persulfate injection into a gasoline source zone.

    Science.gov (United States)

    Sra, Kanwartej S; Thomson, Neil R; Barker, Jim F

    2013-07-01

    One pore volume of unactivated sodium persulfate was delivered into an emplaced gasoline residual source zone at CFB Borden. Concentrations of inorganic species (S2O8(2-), SO4(2-), Na(+), dissolved inorganic carbon (DIC)) and selected gasoline compounds (benzene, toluene, ethylbenzene, xylenes, trimethylbenzenes and naphthalene) were monitored across a transect equipped with 90 multilevel sampling points for >10months post-injection. Mass loading (M˙) of compounds constructed from the transect data was used for assessment purposes. Breakthrough of inorganic species was observed when the injection slug crossed the monitoring transect. An increase in [Formula: see text] indicated persulfate consumption during oxidation of gasoline compounds or degradation due to the interaction with aquifer materials. M˙DIC increased by >100% suggesting some mineralization of gasoline compounds during treatment. Mass loading for all the monitored gasoline compounds reduced by 46 to 86% as the inorganic slug crossed the monitoring transect. The cumulative mass discharge across the monitoring transect was 19 to 58% lower than that expected without persulfate injection. After the inorganic injection slug was flushed from the source zone a partial rebound (40 to 80% of baseline levels) of mass discharge of the monitored gasoline compounds was observed. The ensemble of data collected provides insight into the fate and transport of the injected persulfate solution, and the accompanying treatment of a gasoline the source zone. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. High pressure discharges in cavities formed by microfabrication techniques

    International Nuclear Information System (INIS)

    Khan, B.A.; Cammack, D.A.; Pinker, R.D.; Racz, J.

    1997-01-01

    High pressure discharges are the basis of small high intensity light sources. In this work, we demonstrate the formation of high pressure discharges, in cavities formed by applying micromachining and integrated circuit techniques to quartz substrates. Cavities containing varying amounts of mercury and argon were fabricated to obtain high pressure discharges. A high pressure mercury discharge was formed in the electrodeless cavities by exciting them with a microwave source, operating at 2.45 GHz and in the electroded cavities by applying a dc voltage. The contraction of the discharge into a high pressure arc was observed. A broad emission spectrum due to self-absorption and collisions between excited atoms and normal atoms, typical of high pressure mercury discharges, was measured. The light output and efficacy increased with increasing pressure. The measured voltage was used to estimate the pressure within the electroded cavities, which is as high as 127 atm for one of the two cavities discussed in this work. Efficacies over 40 lumens per watt were obtained for the electrodeless cavities and over 50 scr(l)m/W for the electroded cavities. copyright 1997 American Institute of Physics

  6. California study compares natural/drilling discharge contaminants offshore

    International Nuclear Information System (INIS)

    Steinhauer, W.G.; Imamura, E.; Barminski, J.R.; Neff, J.M.

    1992-01-01

    An analysis of drilling fluid and this paper reports that cuttings discharges in the southern Santa Maria basin offshore California indicates that the amount of metal and hydrocarbon contaminants from drilling operations is small relative to that from natural sources. The metal and hydrocarbon discharges were calculated for only one of the three platforms discharging between 1986 and 1989 in the Point Arguello field. However, assuming concentrations are similar on each platform, the combined input of metals and hydrocarbons over the 3-year period was still low (except for barium and lead) compared to the average annual flux from natural sources. The MMS is monitoring the Santa Maria basin to understand possible long-term environmental effects of oil and gas development (California Monitoring Program, Phase II; and Effects of OCS Production Platforms on Rocky Reef Fishes and Fisheries). A site-specific study area was established to determine effects of drilling-related discharges at Chevron U.S.S. Inc.'s platform Hidalgo in the Point Arguello field. Part of the study included review of discharge records for platforms Hidalgo, Hermosa (Chevron), and Harvest (Texaco Exploration and Production Inc.)

  7. Paediatric vaginal discharge | Makwela | South African Family Practice

    African Journals Online (AJOL)

    Vaginal discharge in the prepubertal patient is a common symptom, and can be a source of distress for the caregiver and concern for the healthcare worker. Several factors predispose these patients to the development of recurrent vaginal discharge. Unless noticed by the caregiver, this problem can persist for long periods ...

  8. The formation of diffuse discharge by short-front nanosecond voltage pulses and the modification of dielectrics in this discharge

    Science.gov (United States)

    Orlovskii, V. M.; Panarin, V. A.; Shulepov, M. A.

    2014-07-01

    The dynamics of diffuse discharge formation under the action of nanosecond voltage pulses with short fronts (below 1 ns) in the absence of a source of additional preionization and the influence of a dielectric film on this process have been studied. It is established that the diffuse discharge is induced by the avalanche multiplication of charge initiated by high-energy electrons and then maintained due to secondary breakdowns propagating via ionized gas channels. If a dielectric film (polyethylene, Lavsan, etc.) is placed on the anode, then multiply repeated discharge will lead to surface and bulk modification of the film material. Discharge-treated polyethylene film exhibits a change in the optical absorption spectrum in the near-IR range.

  9. Estimating sediment discharge: Appendix D

    Science.gov (United States)

    Gray, John R.; Simões, Francisco J. M.

    2008-01-01

    Sediment-discharge measurements usually are available on a discrete or periodic basis. However, estimates of sediment transport often are needed for unmeasured periods, such as when daily or annual sediment-discharge values are sought, or when estimates of transport rates for unmeasured or hypothetical flows are required. Selected methods for estimating suspended-sediment, bed-load, bed- material-load, and total-load discharges have been presented in some detail elsewhere in this volume. The purposes of this contribution are to present some limitations and potential pitfalls associated with obtaining and using the requisite data and equations to estimate sediment discharges and to provide guidance for selecting appropriate estimating equations. Records of sediment discharge are derived from data collected with sufficient frequency to obtain reliable estimates for the computational interval and period. Most sediment- discharge records are computed at daily or annual intervals based on periodically collected data, although some partial records represent discrete or seasonal intervals such as those for flood periods. The method used to calculate sediment- discharge records is dependent on the types and frequency of available data. Records for suspended-sediment discharge computed by methods described by Porterfield (1972) are most prevalent, in part because measurement protocols and computational techniques are well established and because suspended sediment composes the bulk of sediment dis- charges for many rivers. Discharge records for bed load, total load, or in some cases bed-material load plus wash load are less common. Reliable estimation of sediment discharges presupposes that the data on which the estimates are based are comparable and reliable. Unfortunately, data describing a selected characteristic of sediment were not necessarily derived—collected, processed, analyzed, or interpreted—in a consistent manner. For example, bed-load data collected with

  10. Plasma Discharge in Toroidal System

    International Nuclear Information System (INIS)

    Usada, Widdi; Suryadi; Purwadi, Agus; Kasiyo

    1996-01-01

    A toroidal discharge apparatus has been made as an initial research in magnetic confinement system. This system consists of a capacitor, a RF source, an igniter system, a primary coil, a torus, and completed by Rogowski probe as a current detector. In this system, the discharge occurs when the minimum voltage is operated at 5 kV. The experiment result shows that the coupling factor is 0.35, it is proved that there is an equality between estimated and measurement results of the primary inductance i.e 8.5 μH

  11. Acoustic signal analysis in the creeping discharge

    International Nuclear Information System (INIS)

    Nakamiya, T; Sonoda, Y; Tsuda, R; Ebihara, K; Ikegami, T

    2008-01-01

    We have previously succeeded in measuring the acoustic signal due to the dielectric barrier discharge and discriminating the dominant frequency components of the acoustic signal. The dominant frequency components appear over 20kHz of acoustic signal by the dielectric barrier discharge. Recently surface discharge control technology has been focused from practical applications such as ozonizer, NO X reactors, light source or display. The fundamental experiments are carried to examine the creeping discharge using the acoustic signal. When the high voltage (6kV, f = 10kHz) is applied to the electrode, the discharge current flows and the acoustic sound is generated. The current, voltage waveforms of creeping discharge and the sound signal detected by the condenser microphone are stored in the digital memory scope. In this scheme, Continuous Wavelet Transform (CWT) is applied to discriminate the acoustic sound of the micro discharge and the dominant frequency components are studied. CWT results of sound signal show the frequency spectrum of wideband up to 100kHz. In addition, the energy distributions of acoustic signal are examined by CWT

  12. Investigation of the sources and fate of radioactive discharges to public sewers

    International Nuclear Information System (INIS)

    Titley, J.; Carey, A.; Crockett, G.

    2000-01-01

    The practise of disposing of small amounts of liquid radioactive waste from non-nuclear organisations to public sewer systems, is currently being reviewed by the Environment Agency, Scottish Environmental Protection Agency and the Industrial Pollution and Radiochemical Inspectorate. Changing sewage treatment and disposal practises, particularly the increasing use of incineration to treat sewage sludge in urban areas, have prompted this review. This study was undertaken as part of the review process to determine whether disposal into the public sewer system remains a safe disposal option. This report describes a study to investigate the sources and fates of authorised discharges of radionuclides into the sewer system. Sewage transport, treatment, discharge and incineration systems are described and the fate of radionuclides in the systems considered. A model (SMART) was developed to predict radionuclide behaviour through these systems and calculate the resulting doses. Case studies of two large urban sewerage systems were carried out in Leeds and Central London. Leeds is served by one sewage treatment works at Knostrop, which receives disposals of ten radionuclides from six disposers. Up to seven of the radionuclides were measurable in effluents, sludges or incinerator ash at the works. Naturally occurring and fallout radionuclides were also detected. Central London is served by one large works at Beckton which receives disposals of twenty radionuclides from 65 disposers. Up to ten of the disposed radionuclides, plus naturally occurring and fallout radionuclides were detected in effluents, sludges, incinerator cake or ash at Beckton. For both sites the largest authorised disposals were of Tc-99m, C-14, I-125, I-131 and H-3. The behaviour of radionuclides during incineration was assessed using measurements and literature values. The radiological implications of disposals in Leeds and Central London were assessed using the model SMART and by measuring dose rates

  13. Plasma diagnostics discharge parameters and chemistry

    CERN Document Server

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  14. Investigations on afterglows of neon gas discharges

    International Nuclear Information System (INIS)

    Steenhuysen, L.W.G.

    1979-01-01

    Experimental and numerical investigations on afterglows of neon gas discharges are described. The investigated pressure range extends from 0.5 torr to 100 torr; the discharge currents lie between about 1 mA and 100 mA. The decay of the 1s atom densities has been determined experimentally as function of the time elapsed in the afterglow. From the measured decay of metastable 1s 5 atom densities at gas pressure 5 atoms as well as the coefficinets of atomic collisional transfer between the 1s 5 and 1s 4 level are determined. To obtain more insight in the mutual influences of the various loss and production processes of 1s atoms and charge carriers in the afterglow a numerical model has been formed. The behaviour of the afterglow radiation intensity has been measured on discharges with a gas pressure of 1, 10, 20, 50 and 100 torr and a discharge current of 22, 24 and 50 mA. From the results the recombination distribution fractions of the 1s levels are determined and the electron densities at the start of the afterglow of 20, 50 and 100 torr discharges. With the help of the selective excitation spectroscopy the coefficients of atomic transfer between the 2p levels have been measured in the afterglow of discharge with a gas pressure of 1, 10, 20, 50 and 100 torr and a discharge current of 22 mA. From these results and the measured intensities of the various spectral lines in the afterglow the partial recombination coefficients for the 2p levels are calculated. (Auth. )

  15. Reinvestigation of the charge density distribution in arc discharge fusion system

    Energy Technology Data Exchange (ETDEWEB)

    Sheng, Lin Horng; Yee, Lee Kim; Nan, Phua Yeong; Thung, Yong Yun; Khok, Yong Thian; Rahman, Faidz Abd [Centre of Photonics and Advance Material, Universiti Tunku Abdul Rahman Kuala Lumpur (Malaysia)

    2015-04-24

    A continual arc discharge system has been setup and the light intensity of arc discharge has been profiled. The mathematical model of local energy density distribution in arc discharge fusion has been simulated which is in good qualitative agreement with light intensity profile of arc discharge in the experiments. Eventually, the local energy density distribution of arc discharge system is able to be precisely manipulated to act as heat source in the fabrication of fused fiber devices.

  16. Reinvestigation of the charge density distribution in arc discharge fusion system

    International Nuclear Information System (INIS)

    Sheng, Lin Horng; Yee, Lee Kim; Nan, Phua Yeong; Thung, Yong Yun; Khok, Yong Thian; Rahman, Faidz Abd

    2015-01-01

    A continual arc discharge system has been setup and the light intensity of arc discharge has been profiled. The mathematical model of local energy density distribution in arc discharge fusion has been simulated which is in good qualitative agreement with light intensity profile of arc discharge in the experiments. Eventually, the local energy density distribution of arc discharge system is able to be precisely manipulated to act as heat source in the fabrication of fused fiber devices

  17. Basic principles and applications of atmospheric-pressure discharge plasmas

    International Nuclear Information System (INIS)

    Becker, K.H.

    2002-01-01

    The principles that govern the generation and maintenance of atmospheric - pressure discharge plasmas are summarized. The properties and operating parameters of various types such as dielectric barrier discharge plasmas (DBDs), corona discharge plasmas (CDs), microhollow cathode discharge plasmas (MHCDs) , and dielectric capillary electrode discharge plasmas (CDEDs) are introduced. All of them are self sustained, non equilibrium gas discharges that can be operated at atmospheric pressure. CDs and DBDDs represent very similar types of discharges, while DBDs are characterized by insulating layers on one or both electrodes, CDs depend on inhomogeneous electric fields at least in some parts of the electrode configuration to restrict the primary ionization processes to a small fraction of the inter - electrode region. Their application to novel light sources in the ultraviolet (UV) and vacuum ultraviolet (VUV) spectral region is described. (nevyjel)

  18. Luminescent Characteristics of a Pulsed Discharge Plasma in Xe-KBr Mixture

    Science.gov (United States)

    Heneral, A. A.; Zhmenyak, Y. V.

    2018-03-01

    A mixture of xenon with a nontoxic halogen carrier Xe-KBr is used to create a plasma radiation source at the 282-nm transition of the XeBr* molecule excited by a high-voltage pulsed-periodic discharge. The luminescence spectra of the plasma of a longitudinal pulsed-periodic discharge in the Xe-KBr mixture at low pressures are studied experimentally. The most intense UV bands of exciplex XeBr* molecules are recorded in the spectral range of 250-350 nm. The spectral, temporal, and energetic characteristics of the radiation source are presented, as well as the dependence of the XeBr* exciplex molecule formation efficiency on the discharge excitation conditions. The optimal conditions for the excitation of UV radiation in the pulsed-periodic discharge plasma are determined.

  19. Relativistic Electrons in Electric Discharges

    DEFF Research Database (Denmark)

    Cinar, Deniz

    at the time when also gigantic electric discharges were observed at 10-90 km altitude in the stratosphere and mesosphere, the so called “jets” and “sprites”, commonly referred to as “Transient Luminous Events” (TLEs). TGFs were _rst thought connected to TLEs, but later research has pointed to lightning......Thunderstorms generate bursts of X- and Gamma radiation. When observed from spacecraft, the bursts are referred to as “Terrestrial Gamma-ray Flashes” (TGFs). They are bremsstrahlung from energetic electrons accelerated in thunderstorm electric _elds. The TGFs were _rst observed in the 90ties...... discharges as the source. The “Atmosphere-Space Interactions Monitor” (ASIM) for the International Space Station in 2016, led by DTU Space, and the French microsatellite TARANIS, also with launch in 2016, will identify with certainty the source of TGFs. In preparation for the missions, the Ph.D. project has...

  20. Brachytherapy Partial Breast Irradiation: Analyzing Effect of Source Configurations on Dose Metrics Relevant to Toxicity

    International Nuclear Information System (INIS)

    Cormack, Robert A.; Devlin, Phillip M.

    2008-01-01

    Purpose: Recently, the use of partial breast irradiation (PBI) for patients with early-stage breast cancer with low-risk factors has increased. The volume of the high-dose regions has been correlated with toxicity in interstitial treatment. Although no such associations have been made in applicator-based experience, new applicators are being developed that use complex noncentered source configurations. This work studied the effect of noncentered source placements on the volume of the high-dose regions around a spherical applicator. Methods and Materials: Many applicator configurations were numerically simulated for a range of inflation radii. For each configuration, a dose homogeneity index was used as a dose metric to measure the volume of the high-dose region. Results: All multisource configurations examined resulted in an increase of the high-dose region compared with a single-center source. The resulting decrease in the prescription dose homogeneity index was more pronounced for sources further from the center of the applicator, and the effect was reduced as the number of dwell locations was increased. Conclusion: The geometries of particular applicators were not considered to achieve a more general result. On the basis of the calculations of this work, it would appear that treatment using noncentered dwell locations will lead to an increase in the volume of the high-dose regions

  1. Quantitative x-ray absorption imaging with a broadband source: application to high-intensity discharge lamps

    Energy Technology Data Exchange (ETDEWEB)

    Curry, J J [National Institute of Standards and Technology, Gaithersburg, MD 20899-8422 (United States)], E-mail: jjcurry@nist.gov

    2008-07-21

    The case of x-ray absorption imaging in which the x-ray source is broadband and the detector does not provide spectral resolution is analysed. The specific motivation is observation of the Hg vapour distribution in high-intensity discharge (HID) lamps. When absorption by the vapour is small, the problem can be couched accurately in terms of a mean absorption cross section averaged over the x-ray spectral distribution, weighted by the energy-dependent response of the detector. The method is tested against a Au foil standard and then applied to Hg. The mean absorption cross section for Hg is calculated for a Ag-anode x-ray tube at accelerating voltages of 25, 30 and 35 kV, and for HIDs in fused silica or polycrystalline alumina arc tubes.

  2. The characteristics of SPECT images in childhood benign partial epilepsy

    International Nuclear Information System (INIS)

    Jia Shaowei; Liao Jianxiang; Liu Xiaoyan; Zheng Xiyuan; Qin Jiong; Pan Zhongyun; Zuo Qihua

    1998-01-01

    Purpose: To investigate childhood benign partial epilepsy (BPE) with SPECT. Methods: Double SPECT imaging was performed on 21 cases of BPE at the stage of wake (interval spike discharge) and sleep (spike discharge), under EEG monitoring. The transverse images were reconstructed after digital image subtraction. The quantitative analysis was conducted with brain flow change rate (BFCR) % mathematical model. Results: EEG monitoring demonstrated approximately normal background of 21 cases of BPE during the stage of wake, and spike discharge frequency markedly increased during the stage of sleep, 117 foci were showed by SPeCT in cases of BPE, and the average was 5.6 +- 1.6 foci/case. The characteristics of SPECT transverse images were 1) multiple foci of mirror, 2) mostly seen in Rolandic region, 3) circular symbol, 4) the radioactivity in foci decreased during the stage of wake (interval spike discharge) and increased during the stage of sleep (spike discharge). The concordance of SPECT and EEG was 93.1% (109/117 foci). The BFCR% of all epileptogenic foci exceeded normal limit (99% confidence interval). There was no correlation between the spike discharge frequency and BFCR% (r = 0.45, P>0.05). Conclusions: Regional cerebral blood flow and function were abnormal during the epileptogenic foci were discharging abnormally in BPE

  3. Partial discharge localization in power transformers based on the sequential quadratic programming-genetic algorithm adopting acoustic emission techniques

    Science.gov (United States)

    Liu, Hua-Long; Liu, Hua-Dong

    2014-10-01

    Partial discharge (PD) in power transformers is one of the prime reasons resulting in insulation degradation and power faults. Hence, it is of great importance to study the techniques of the detection and localization of PD in theory and practice. The detection and localization of PD employing acoustic emission (AE) techniques, as a kind of non-destructive testing, plus due to the advantages of powerful capability of locating and high precision, have been paid more and more attention. The localization algorithm is the key factor to decide the localization accuracy in AE localization of PD. Many kinds of localization algorithms exist for the PD source localization adopting AE techniques including intelligent and non-intelligent algorithms. However, the existed algorithms possess some defects such as the premature convergence phenomenon, poor local optimization ability and unsuitability for the field applications. To overcome the poor local optimization ability and easily caused premature convergence phenomenon of the fundamental genetic algorithm (GA), a new kind of improved GA is proposed, namely the sequence quadratic programming-genetic algorithm (SQP-GA). For the hybrid optimization algorithm, SQP-GA, the sequence quadratic programming (SQP) algorithm which is used as a basic operator is integrated into the fundamental GA, so the local searching ability of the fundamental GA is improved effectively and the premature convergence phenomenon is overcome. Experimental results of the numerical simulations of benchmark functions show that the hybrid optimization algorithm, SQP-GA, is better than the fundamental GA in the convergence speed and optimization precision, and the proposed algorithm in this paper has outstanding optimization effect. At the same time, the presented SQP-GA in the paper is applied to solve the ultrasonic localization problem of PD in transformers, then the ultrasonic localization method of PD in transformers based on the SQP-GA is proposed. And

  4. Fast Partial Evaluation of Pattern Matching in Strings

    DEFF Research Database (Denmark)

    Ager, Mads Sig; Danvy, Olivier; Rohde, Henning Korsholm

    2003-01-01

    We show how to obtain all of Knuth, Morris, and Pratt's linear-time string matcher by partial evaluation of a quadratic-time string matcher with respect to a pattern string. Although it has been known for 15 years how to obtain this linear matcher by partial evaluation of a quadratic one, how...... to obtain it in linear time has remained an open problem.Obtaining a linear matcher by partial evaluation of a quadratic one is achieved by performing its backtracking at specialization time and memoizing its results. We show (1) how to rewrite the source matcher such that its static intermediate...... computations can be shared at specialization time and (2) how to extend the memoization capabilities of a partial evaluator to static functions. Such an extended partial evaluator, if its memoization is implemented efficiently, specializes the rewritten source matcher in linear time....

  5. Glow-discharge-created electron beams and beam-excited lasers

    International Nuclear Information System (INIS)

    Meyer, J.D.

    1989-01-01

    Efficiently created glow discharge electron beams have been developed and studied in detail. The beam mode of operation occurs in the abnormal glow adjacent to the glow-to-arc transition regime. In contrast to electron beams generated in high vacuum from thermionic electron emitting sources, this type of discharge creates electrons directly in soft vacuum by secondary electron emission from cold cathode surfaces following the bombardment of the cathode surface by fast ions and neutral atoms. Factors influencing the efficient electron emission from cold cathodes are presented with emphasis on cathode materials. Sintered ceramic-metal cathodes and oxide-coated cathodes are presented, both of which can produce high power, efficiently generated, d.c. electron beams with discharge currents up to 1 amp (∼130 mA/cm 2 ) at volt ages of up to 6 kV. Novel cathode designs and discharge geometries are presented with specific emphasis on both self-focussed beams emitted from circular cathodes and line-source electron beams emitted from rectangular cathodes forming a thin sheet of electrons. Electrostatically focussed line-source electron beams are spatially characterized by experimentally measuring the effect of discharge parameters and cathode design upon the focussed beam width, focal point, and uniformity. This is achieved by scanning a current collecting detector in three dimensions in order to profile the distribution of electron beam current. Discharge electron beams are further characterized by their electron energy distribution. Measured electron flux energy distributions of transmitted beam electrons in the negative glow are compared to theoretical models. The relative effects of elastic and inelastic collisions mechanisms upon both the overall form and detailed structure of the energy distribution are discussed

  6. Correlation-Based Amplitude Estimation of Coincident Partials in Monaural Musical Signals

    Directory of Open Access Journals (Sweden)

    Jayme Garcia Arnal Barbedo

    2010-01-01

    Full Text Available This paper presents a method for estimating the amplitude of coincident partials generated by harmonic musical sources (instruments and vocals. It was developed as an alternative to the commonly used interpolation approach, which has several limitations in terms of performance and applicability. The strategy is based on the following observations: (a the parameters of partials vary with time; (b such a variation tends to be correlated when the partials belong to the same source; (c the presence of an interfering coincident partial reduces the correlation; and (d such a reduction is proportional to the relative amplitude of the interfering partial. Besides the improved accuracy, the proposed technique has other advantages over its predecessors: it works properly even if the sources have the same fundamental frequency, it is able to estimate the first partial (fundamental, which is not possible using the conventional interpolation method, it can estimate the amplitude of a given partial even if its neighbors suffer intense interference from other sources, it works properly under noisy conditions, and it is immune to intraframe permutation errors. Experimental results show that the strategy clearly outperforms the interpolation approach.

  7. Low-pressure glow discharges with oscillating electrons in different electrode systems

    International Nuclear Information System (INIS)

    Bersenev, V.V.; Gavriolv, N.V.; Nikulin, S.P.

    1995-01-01

    One of the main applications of low - pressure glow discharges is the development on their basis of charged - particle beam sources. The use of glow discharges with oscillating electrons, which can operate stably in the voltage and pressure range to the left of the left branch of Pashen's curve, shows promise, because the decrease in critical pressure p 0 , below which the discharge operation becomes impossible, in the discharge system of a source promotes an increase in the electrical strength of its accelerating system. This, in its turn, makes possible the expansion of the operation range of accelerating voltages. This experimental investigation of glow discharges in such well - known systems with oscillating electrons, as Hollow Cathode (HC), Penning's System (PS) and Inverse Magnetron (IM), is aimed at revealing the system operating at the lowest pressure. Besides, both common features and peculiarities of discharge operation in these systems are discussed. Though there is an extensive amount of published information covering all the specified discharges, the carrying out of such investigation is justified, since a comparative analysis of results obtained by different authors is hampered by various conditions of their experiments

  8. Extra source implantation for suppression floating-body effect in partially depleted SOI MOSFETs

    International Nuclear Information System (INIS)

    Chen Jing; Luo Jiexin; Wu Qingqing; Chai Zhan; Huang Xiaolu; Wei Xing; Wang Xi

    2012-01-01

    Silicon-on-insulate (SOI) MOSFETs offer benefits over bulk competitors for fully isolation and smaller junction capacitance. The performance of partially depleted (PD) SOI MOSFETs, though, is not good enough. Since the body is floating, the extra holes (for nMOSFETs) in this region accumulate, causing body potential arise, which of course degrades the performance of the device. How to suppress the floating-body effect becomes critical. There are mainly two ways for the goal. One is to employ body-contact structures, and the other SiGe source/drain structures. However, the former consumes extra area, not welcomed in the state-of-the-art chips design. The latter is not compatible with the traditional CMOS technology. Finding a structure both saving area and compatible technology is the most urgent for PD SOI MOSFETs. Recently, we have developed a new structure with extra heavy boron implantation in the source region for PD SOI nMOSFETs. It consumes no extra area and is also compatible with CMOS technology. The device is found to be free of kink effect in simulation, which implies the floating-body effect is greatly suppressed. In addition, the mechanisms of the kink-free, as well as the impact of different implanting conditions are interpreted.

  9. Geochemistry of Ua Huka basalts (Marquesas): partial melting variations and mantle source heterogeneity

    International Nuclear Information System (INIS)

    Ielsch, G.; Caroff, M.; Maury, R.C.; Cotten, J.; Barsczus, H.G.; Guillou, H.

    1998-01-01

    The main shield volcano of Ua Huka Island (Marquesas Archipelago) was emplaced between 2.2 and 2.4 Ma, and then affected by two caldera collapse events. After a 0.9 Ma-long gap, volcanic activity resumed with the emplacement of two smaller volcanoes in the southwest part of the island, between 1.5 and 0.75 Ma. The geochemical characteristics of Ua Huka mafic lavas, which range from olivine tholeiites to alkali basalts and basanites, are consistent with a temporal decrease in partial melting degrees of a heterogeneous mantle source. The associated temporal variation of the isotopic signatures of Ua Huka basalts implies a more important contribution of a Depleted MORB Mantle (DMM) end-member during the genesis of the youngest basanitic lavas. Such a variation was not previously documented in the Marquesas Archipelago. (authors)

  10. Polyaniline/partially exfoliated multi-walled carbon nanotubes based nanocomposites for supercapacitors

    International Nuclear Information System (INIS)

    Potphode, Darshna D.; Sivaraman, P.; Mishra, Sarada P.; Patri, Manoranjan

    2015-01-01

    In the present study, polyaniline (PANI)/partially exfoliated multi-walled carbon nanotubes (Px-MWCNT) nanocomposites were investigated for supercapacitor application. Nanocomposites with varying weight/weight ratio of PANI and Px-MWCNT were prepared by in-situ polymerization of aniline over Px-MWCNT. Transmission and scanning electron microscopic analysis showed that the MWCNT was partial unzipped along the length of tubes. The morphology of PANI/Px-MWCNT nanocomposites exhibited wrapping of PANI over Px-MWCNT. Symmetric supercapacitors containing PANI/Px-MWCNT nanocomposites as the electrode material were fabricated. The electrochemical characterization of the nanocomposites was carried by two electrode method (unit cell configuration). Cyclic voltammetric analysis showed a synergistic increase in specific capacitance of the nanocomposites. Charge-discharge cycle study indicated that nanocomposites have greater charge-discharge rate capability than pure PANI. The observed result is attributed to the shorter diffusion length of ions in the nanocomposites as compared to that of pure PANI. The electrochemical impedance spectra of supercapacitors were resolved into real and losscapacitances. The loss capacitance indicated that the time constant of the nanocomposites decreases with increase in the Px-MWCNT content. The supercapacitors showed enhanced stability during continuous charge-discharge cycling as the PX-MWCNT content in the nanocomposites increased. PANI-50 and PANI-25 nanocomposites based supercapacitors exhibited 91% and 93% capacitive retention after 2000 charge-discharge cycle while pure PANI showed only 67% capacitance retention for the same number of cycles

  11. Experiments on Ion-Ion Plasmas From Discharges

    Science.gov (United States)

    Leonhardt, Darrin; Walton, Scott; Blackwell, David; Murphy, Donald; Fernsler, Richard; Meger, Robert

    2001-10-01

    Use of both positive and negative ions in plasma processing of materials has been shown to be advantageous[1] in terms of better feature evolution and control. In this presentation, experimental results are given to complement recent theoretical work[2] at NRL on the formation and decay of pulsed ion-ion plasmas in electron beam generated discharges. Temporally resolved Langmuir probe and mass spectrometry are used to investigate electron beam generated discharges during the beam on (active) and off (afterglow) phases in a variety of gas mixtures. Because electron-beam generated discharges inherently[3] have low electron temperatures (<0.5eV in molecular gases), negative ion characteristics are seen in the active as well as afterglow phases since electron detachment increases with low electron temperatures. Analysis of temporally resolved plasma characteristics deduced from these measurements will be presented for pure O_2, N2 and Ar and their mixtures with SF_6. Oxygen discharges show no noticeable negative ion contribution during the active or afterglow phase, presumably due to the higher energy electron attachment threshold, which is well above any electron temperature. In contrast, SF6 discharges demonstrate ion-ion plasma characteristics in the active glow and are completely ion-ion in the afterglow. Comparison between these discharges with published cross sections and production mechanisms will also be presented. [1] T.H. Ahn, K. Nakamura & H. Sugai, Plasma Sources Sci. Technol., 5, 139 (1996); T. Shibyama, H. Shindo & Y. Horiike, Plasma Sources Sci. Technol., 5, 254 (1996). [2] See presentation by R. F. Fernsler, at this conference. [3] D. Leonhardt, et al., 53rd Annual GEC, Houston, TX.

  12. Determination of plasma spot current and arc discharge plasma current on the system of plasma cathode electron sources using Rogowski coil technique

    International Nuclear Information System (INIS)

    Wirjoadi; Bambang Siswanto; Lely Susita RM; Agus Purwadi; Sudjatmoko

    2015-01-01

    It has been done the function test experiments of ignitor electrode system and the plasma generator electrode system to determine the current spot plasma and arc discharge plasma current with Rogowski coil technique. Ignitor electrode system that gets power supply from IDPS system can generate the plasma spot current of 11.68 ampere to the pulse width of about 33 μs, this value is greater than the design probably because of electronic components used in the IDPS system was not as planned. For the plasma generator electrode system that gets power from ADPS system capable of producing an arc discharge plasma current around 103.15 amperes with a pulse width of about 96 μs, and this value as planned. Based on the value of the arc discharge plasma current can be determined plasma electron density, which is about 10.12 10"1"9 electrons/m"3, and with this electron density value, an ignitor electrode system and a plasma generator system is quite good if used as a plasma cathode electron source system. (author)

  13. High-performance cathode elements for gas-discharge light sources

    Directory of Open Access Journals (Sweden)

    Sevastyanov V. V.

    2009-02-01

    Full Text Available Application of cathode elements of the arc-discharge activator made on the basis of developed material — alloy of iridium and rare-earth metals (of cerium group — has been suggested. The working samples of arc lamps have been produced and tested. The location of metal-alloy cathode has been optimized. The tests demonstrated, that after 4500 hours of work the lighting-up and glowing parameters of such lamps remained stable.

  14. Liquid sampling-atmospheric pressure glow discharge as a secondary excitation source: Assessment of plasma characteristics

    Science.gov (United States)

    Manard, Benjamin T.; Gonzalez, Jhanis J.; Sarkar, Arnab; Dong, Meirong; Chirinos, Jose; Mao, Xianglei; Russo, Richard E.; Marcus, R. Kenneth

    The liquid sampling-atmospheric pressure glow discharge (LS-APGD) has been assessed as a secondary excitation source with a parametric evaluation regarding carrier gas flow rate, applied current, and electrode distance. With this parametric evaluation, plasma optical emission was monitored in order to obtain a fundamental understanding with regards to rotational temperature (Trot), excitation temperature (Texc), electron number density (ne), and plasma robustness. Incentive for these studies is not only for a greater overall fundamental knowledge of the APGD, but also in instrumenting a secondary excitation/ionization source following laser ablation (LA). Rotational temperatures were determined through experimentally fitting of the N2 and OH molecular emission bands while atomic excitation temperatures were calculated using a Boltzmann distribution of He and Mg atomic lines. The rotational and excitation temperatures were determined to be ~ 1000 K and ~ 2700 K respectively. Electron number density was calculated to be on the order of ~ 3 × 1015 cm- 3 utilizing Stark broadening effects of the Hα line of the Balmer series and a He I transition. In addition, those diagnostics were performed introducing magnesium (by solution feed and laser ablation) into the plasma in order to determine any perturbation under heavy matrix sampling. The so-called plasma robustness factor, derived by monitoring Mg II/Mg I emission ratios, is also employed as a reflection of potential perturbations in microplasma energetics across the various operation conditions and sample loadings. While truly a miniaturized source (laser ablation sample introduction.

  15. Angina - discharge

    Science.gov (United States)

    Chest pain - discharge; Stable angina - discharge; Chronic angina - discharge; Variant angina - discharge; Angina pectoris - discharge; Accelerating angina - discharge; New-onset angina - discharge; Angina-unstable - discharge; ...

  16. Laser ablation/ionization studies in a glow discharge

    International Nuclear Information System (INIS)

    Hess, K.R.; Harrison, W.W.

    1985-01-01

    The pin cathode glow discharge is used in the laboratory as an atomization/ionization source for a variety of applications, including solids mass spectrometry. Coupled with a tunable dye laser, the glow discharge may also serve as an atom reservoir for resonance ionization mass spectrometry in which the laser ionizes the discharge sputtered atoms. By tightly focusing the laser onto solid samples, various ablation effects may also be investigated. The laser may be used to generate an ionized plasma which may be directly analyzed by mass spectrometry. Alternatively, the ablated neutral atoms may be used in post-ablation excitation/ionization processes, in this case the glow discharge. The results of these investigations are the basis of this paper

  17. Investigation of plasma potential and pulsed discharge characteristics in enhanced glow discharge plasma immersion ion implantation and deposition

    International Nuclear Information System (INIS)

    Li Liuhe; Lu Qiuyuan; Fu, Ricky K.Y.; Chu, Paul K.

    2009-01-01

    Enhanced glow discharge plasma immersion ion implantation and deposition (EGD-PII and D) does not require external plasma sources. In this technique, the plasma is produced by self-glow discharge when a high negative voltage is applied to the sample. The small-area, pointed-shape hollow anode and large area tabular cathode form an electron-focused electric field. Using a special electric field design, the electrons from either the plasma or target (secondary electrons) are focused to a special hollow anode. As a result of the special electron-focusing field, the self-glow discharge process can be enhanced to achieve effective ion implantation into the substrate. In this work, the plasma potential distribution is investigated in details and the possible pulse discharge mechanism is discussed. The unique characteristics of the pulsed plasma and plasma extinction are studied.

  18. X-ray preionization for electric discharge lasers

    International Nuclear Information System (INIS)

    Lin, S.; Levatter, J.I.

    1979-01-01

    Using x rays of 60--200-keV photon energy (lambdaapprox.0.06--0.2 A) as an ionizing radiation source in a transmission-line-driven low-inductance discharge chamber, we have succeeded in generating spatially homogeneous pulsed avalanche discharges of several liter volume at greater than 1 atm pressure for up to 100-nsec duration. In concurrent laser generation experiments with relatively lossy windows, we have observed high-optical-quality pulsed uv laser output of up to 2 J/liter from such discharges in rare-gas/halogen mixtures, and IR laser output of up to 12.5 J/liter from a He/N 2 /CO 2 mixture

  19. Dynamic of ozone formation in nanosecond microwave discharges

    International Nuclear Information System (INIS)

    Akhmedzhanov, R.A.; Vikharev, A.L.; Gorbachev, A.M.

    1995-01-01

    Nanosecond gas discharges are efficient sources of chemically active plasma. Studies of the nanosecond microwave discharge are interesting for remote modification of the chemical composition of the atmosphere in term of its purification, for diagnostics of impurities and ozone replenishment in the regions of local open-quotes ozone holesclose quotes. In this connection a study of plasma chemical processes in such a discharge seems appropriate, as well as modeling of ecological consequences of the effect of powerful microwave radiation on the atmosphere. The present paper contains generalized results of studying the process of ozone formation in a pulse-periodic freely localized nanosecond microwave discharge. The experiments were performed in a wide range of parameters: microwave radiation wavelength λ = 0.8 and 3cm, pulse duration τ = 6 and 500ns, pulse power P = 50kW and 20MW, pulse repetition rate F = 1-10 3 Hz. The working gases were air and oxygen under pressure P = 10-100Torr. As a source of the microwave radiation a pulse magnetron was used with a device for pulse compression based on the waveguide resonator, and a relativistic microwave generator. The discharge was produced in the focus of the parabolic mirror and had the form of homogeneous cylinder. The plasma chemical processes were studied in two cases. The discharge was created either in the quartz tube placed along the focal line of the mirror or in the free air. Dynamics of formation of ozone and nitrogen oxides in the discharge was studied by means of absorption spectroscopy in the regime of accumulation of the products of chemical reactions (in a closed volume) and their diffusion spreading

  20. Plasma processes in water under effect of short duration pulse discharges

    Science.gov (United States)

    Gurbanov, Elchin

    2013-09-01

    It is very important to get a clear water without any impurities and bacteria by methods, that don't change the physical and chemical indicators of water now. In this article the plasma processes during the water treatment by strong electric fields and short duration pulse discharges are considered. The crown discharge around an electrode with a small radius of curvature consists of plasma leader channels with a high conductivity, where the thermo ionization processes and UV-radiation are taken place. Simultaneously the partial discharges around potential electrode lead to formation of atomic oxygen and ozone. The spark discharge arises, when plasma leader channels cross the all interelectrode gap, where the temperature and pressure are strongly grown. As a result the shock waves and dispersing liquid streams in all discharge gap are formed. The plasma channels extend, pressure inside it becomes less than hydrostatic one and the collapse and UV-radiation processes are started. The considered physical processes can be successfully used as a basis for development of pilot-industrial installations for conditioning of drinking water and to disinfecting of sewage.

  1. Power supply instrumentation for pulsed dielectric barrier discharges

    International Nuclear Information System (INIS)

    Quiroz Velázquez, V E; López Callejas, R; De la Piedad Beneitez, A; Rodríguez Méndez, B G; Peña Eguiluz, R; Muñoz Castro, A E; Barocio, S R; Mercado Cabrera, A; Valencia Alvarado, R

    2012-01-01

    The design and implementation of a pulsed high voltage supply intended to the production and control of pulsed dielectric barrier discharges are reported. The instrumentation includes three independently built DC sources coupled to Flyback-like converters using three 1:50 high voltage transformers. The system is capable of supplying voltages up to 70 kV at a 100-2000 Hz repetition rate, delivering 1-500 μs wide pulses. The system has been applied to the development of pulsed dielectric barrier discharges in a stainless steel coaxial reactor 30 cm long and with a 2.54 cm diameter. The inner nickel electrode diameter is 0.005 cm and is embedded in alumina. The discharges have been carried out in room pressure air. Discharges have been implemented. The discharge is made is a water environment for purposes of bacterial elimination.

  2. Pulsed Electron Source with Grid Plasma Cathode and Longitudinal Magnetic Field for Modification of Material and Product Surfaces

    Science.gov (United States)

    Devyatkov, V. N.; Koval, N. N.

    2018-01-01

    The description and the main characteristics of the pulsed electron source "SOLO" developed on the basis of the plasma cathode with grid stabilization of the emission plasma boundary are presented. The emission plasma is generated by a low-pressure arc discharge, and that allows to form the dense low-energy electron beam with a wide range of independently adjustable parameters of beam current pulses (pulse duration of 20-250 μs, pulse repetition rate of 1-10 s-1, amplitude of beam current pulses of 20-300 A, and energy of beam electrons of 5-25 keV). The special features of generation of emission plasma by constricted low-pressure arc discharge in the grid plasma cathode partially dipped into a non-uniform magnetic field and of formation and transportation of the electron beam in a longitudinal magnetic field are considered. The application area of the electron source and technologies realized with its help are specified.

  3. Synergetic mechanism of methanol–steam reforming reaction in a catalytic reactor with electric discharges

    International Nuclear Information System (INIS)

    Kim, Taegyu; Jo, Sungkwon; Song, Young-Hoon; Lee, Dae Hoon

    2014-01-01

    Highlights: • Methanol–steam reforming was performed on Cu catalysts under an electric discharge. • Discharge had a synergetic effect on the catalytic reaction for methanol conversion. • Discharge lowered the temperature for catalyst activation or light off. • Discharge controlled the yield and selectivity of species in a reforming process. • Adsorption triggered by a discharge was a possible mechanism for a synergetic effect. - Abstract: Methanol–steam reforming was performed on Cu/ZnO/Al 2 O 3 catalysts under an electric discharge. The discharge occurred between the electrodes where the catalysts were packed. The electric discharge was characterized by the discharge voltage and electric power to generate the discharge. The existence of a discharge had a synergetic effect on the catalytic reaction for methanol conversion. The electric discharge provided modified reaction paths resulting in a lower temperature for catalyst activation or light off. The discharge partially controlled the yield and selectivity of species in a reforming process. The aspect of control was examined in view of the reaction kinetics. The possible mechanisms for the synergetic effect between the catalytic reaction and electric discharge on methanol–steam reforming were addressed. A discrete reaction path, particularly adsorption triggered by an electric discharge, was suggested to be the most likely mechanism for the synergetic effect. These results are expected to provide a guide for understanding the plasma–catalyst hybrid reaction

  4. Modeling High Pressure Micro Hollow Cathode Discharges

    National Research Council Canada - National Science Library

    Boeuf, Jean-Pierre; Pitchford, Leanne

    2004-01-01

    This report results from a contract tasking CPAT as follows: The Grantee will perform theoretical modeling of point, surface, and volume high-pressure plasmas created using Micro Hollow Cathode Discharge sources...

  5. Discharge Planning in Chronic Conditions

    Science.gov (United States)

    McMartin, K

    2013-01-01

    Background Chronically ill people experience frequent changes in health status accompanied by multiple transitions between care settings and care providers. Discharge planning provides support services, follow-up activities, and other interventions that span pre-hospital discharge to post-hospital settings. Objective To determine if discharge planning is effective at reducing health resource utilization and improving patient outcomes compared with standard care alone. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2004, until December 13, 2011. Review Methods Reports, randomized controlled trials, systematic reviews, and meta-analyses with 1 month or more of follow-up and limited to specified chronic conditions were examined. Outcomes included mortality/survival, readmissions and emergency department (ED) visits, hospital length of stay (LOS), health-related quality of life (HRQOL), and patient satisfaction. Results One meta-analysis compared individualized discharge planning to usual care and found a significant reduction in readmissions favouring individualized discharge planning. A second meta-analysis compared comprehensive discharge planning with postdischarge support to usual care. There was a significant reduction in readmissions favouring discharge planning with postdischarge support. However, there was significant statistical heterogeneity. For both meta-analyses there was a nonsignificant reduction in mortality between the study arms. Limitations There was difficulty in distinguishing the relative contribution of each element within the terms “discharge planning” and “postdischarge support.” For most studies, “usual care” was not explicitly described. Conclusions Compared with usual care, there was moderate quality evidence that individualized discharge planning is more effective at reducing readmissions or hospital LOS but not mortality, and very low quality evidence that it is more

  6. Identification of nitrate sources and discharge-depending nitrate dynamics in a mesoscale catchment

    Science.gov (United States)

    Mueller, Christin; Strachauer, Ulrike; Brauns, Mario; Musolff, Andreas; Kunz, Julia Vanessa; Brase, Lisa; Tarasova, Larisa; Merz, Ralf; Knöller, Kay

    2017-04-01

    During the last decades, nitrate concentrations in surface and groundwater have increased due to land use change and accompanying application of fertilizer in agriculture as well as increased atmospheric deposition. To mitigate nutrient impacts on downstream aquatic ecosystems, it is important to quantify potential nitrate sources, instream nitrate processing and its controls in a river system. The objective of this project is to characterize and quantify (regional) scale dynamics and trends in water and nitrogen fluxes of the entire Holtemme river catchment in central Germany making use of isotopic fingerprinting methods. Here we compare two key date sampling campaigns in 2014 and 2015, with spatially highly resolved measurements of discharge at 23 sampling locations including 11 major tributaries and 12 locations at the main river. Additionally, we have data from continuous runoff measurements at 10 locations operated by the local water authorities. Two waste water treatment plants contribute nitrogen to the Holtemme stream. This contribution impacts nitrate loads and nitrate isotopic signatures depending on the prevailing hydrological conditions. Nitrogen isotopic signatures in the catchment are mainly controlled by different sources (nitrified soil nitrogen in the headwater and manure/ effluents from WWTPs in the lowlands) and increase with raising nitrate concentrations along the main river. Nitrate loads at the outlet of the catchment are extremely different between both sampling campaigns (2014: NO3- = 97 t a-1, 2015: NO3- = 5 t a-1) which is associated with various runoff (2014: 0.8 m3 s-1, 2015: 0.2 m3 s-1). In 2015, the inflow from WWTP's raises the NO3- loads and enriches δ18O-NO3 values. Generally, oxygen isotope signatures from nitrate are more variable and are controlled by biogeochemical processes in concert with the oxygen isotopic composition of the ambient water. Elevated δ18O-NO3 in 2015 are most likely due to higher temperatures and lower

  7. Chemistry of groundwater discharge inferred from longitudinal river sampling

    Science.gov (United States)

    Batlle-Aguilar, J.; Harrington, G. A.; Leblanc, M.; Welch, C.; Cook, P. G.

    2014-02-01

    We present an approach for identifying groundwater discharge chemistry and quantifying spatially distributed groundwater discharge into rivers based on longitudinal synoptic sampling and flow gauging of a river. The method is demonstrated using a 450 km reach of a tropical river in Australia. Results obtained from sampling for environmental tracers, major ions, and selected trace element chemistry were used to calibrate a steady state one-dimensional advective transport model of tracer distribution along the river. The model closely reproduced river discharge and environmental tracer and chemistry composition along the study length. It provided a detailed longitudinal profile of groundwater inflow chemistry and discharge rates, revealing that regional fractured mudstones in the central part of the catchment contributed up to 40% of all groundwater discharge. Detailed analysis of model calibration errors and modeled/measured groundwater ion ratios elucidated that groundwater discharging in the top of the catchment is a mixture of local groundwater and bank storage return flow, making the method potentially useful to differentiate between local and regional sourced groundwater discharge. As the error in tracer concentration induced by a flow event applies equally to any conservative tracer, we show that major ion ratios can still be resolved with minimal error when river samples are collected during transient flow conditions. The ability of the method to infer groundwater inflow chemistry from longitudinal river sampling is particularly attractive in remote areas where access to groundwater is limited or not possible, and for identification of actual fluxes of salts and/or specific contaminant sources.

  8. Magnesium-aerial primary current source

    Directory of Open Access Journals (Sweden)

    Barba I. N.

    2007-12-01

    Full Text Available Novel metal-air chemical power sources (CPS 3,0-ВМБ-7,5 have been developed. They have an unlimited shelf life and, even after decades of storage, give almost 100% of the designed capacity. These sources are water-activated. An aqueous salt solution is used as an electrolyte. Such sources are designed for single continuous or discontinuous discharge. The paper presents electrochemical reactions at the electrodes during CPS discharge. Comparison of electrical characteristics of the developed power source and various types of "dry cells" has shown that the developed sources have higher energy characteristics.

  9. Analysis of the Sensitivity of K-Type Molecular Sieve-Deposited MWNTs for the Detection of SF₆ Decomposition Gases under Partial Discharge.

    Science.gov (United States)

    Zhang, Xiaoxing; Li, Xin; Luo, Chenchen; Dong, Xingchen; Zhou, Lei

    2015-11-11

    Sulfur hexafluoride (SF6) is widely utilized in gas-insulated switchgear (GIS). However, part of SF6 decomposes into different components under partial discharge (PD) conditions. Previous research has shown that the gas responses of intrinsic and 4 Å-type molecular sieve-deposited multi-wall carbon nanotubes (MWNTs) to SOF2 and SO2F2, two important decomposition components of SF6, are not obvious. In this study, a K-type molecular sieve-deposited MWNTs sensor was developed. Its gas response characteristics and the influence of the mixture ratios of gases on the gas-sensing properties were studied. The results showed that, for sensors with gas mixture ratios of 5:1, 10:1, and 20:1, the resistance change rate increased by nearly 13.0% after SOF2 adsorption, almost 10 times that of MWNTs sensors, while the sensors' resistance change rate with a mixture ratio of 10:1 reached 17.3% after SO2F2 adsorption, nearly nine times that of intrinsic MWNT sensors. Besides, a good linear relationship was observed between concentration of decomposition components and the resistance change rate of sensors.

  10. Occurrence of epileptiform discharges and sleep during EEG recordings in children after melatonin intake versus sleep-deprivation.

    Science.gov (United States)

    Gustafsson, Greta; Broström, Anders; Ulander, Martin; Vrethem, Magnus; Svanborg, Eva

    2015-08-01

    To determine if melatonin is equally efficient as partial sleep deprivation in inducing sleep without interfering with epileptiform discharges in EEG recordings in children 1-16 years old. We retrospectively analysed 129 EEGs recorded after melatonin intake and 113 EEGs recorded after partial sleep deprivation. Comparisons were made concerning occurrence of epileptiform discharges, the number of children who fell asleep and the technical quality of EEG recordings. Comparison between different age groups was also made. No significant differences were found regarding occurrence of epileptiform discharges (33% after melatonin intake, 36% after sleep deprivation), or proportion of unsuccessful EEGs (8% and 10%, respectively). Melatonin and sleep deprivation were equally efficient in inducing sleep (70% in both groups). Significantly more children aged 1-4 years obtained sleep after melatonin intake in comparison to sleep deprivation (82% vs. 58%, p⩽0.01), and in comparison to older children with melatonin induced sleep (58-67%, p⩽0.05). Sleep deprived children 9-12 years old had higher percentage of epileptiform discharges (62%, p⩽0.05) compared to younger sleep deprived children. Melatonin is equally efficient as partial sleep deprivation to induce sleep and does not affect the occurrence of epileptiform discharges in the EEG recording. Sleep deprivation could still be preferable in older children as melatonin probably has less sleep inducing effect. Melatonin induced sleep have advantages, especially in younger children as they fall asleep easier than after sleep deprivation. The procedure is easier for the parents than keeping a young child awake for half the night. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Plasma-surface interaction in negative hydrogen ion sources

    Science.gov (United States)

    Wada, Motoi

    2018-05-01

    A negative hydrogen ion source delivers more beam current when Cs is introduced to the discharge, but a continuous operation of the source reduces the beam current until more Cs is added to the source. This behavior can be explained by adsorption and ion induced desorption of Cs atoms on the plasma grid surface of the ion source. The interaction between the ion source plasma and the plasma grid surface of a negative hydrogen ion source is discussed in correlation to the Cs consumption of the ion source. The results show that operation with deuterium instead of hydrogen should require more Cs consumption and the presence of medium mass impurities as well as ions of the source wall materials in the arc discharge enlarges the Cs removal rate during an ion source discharge.

  12. Chaotic characteristics of corona discharges in atmospheric air

    International Nuclear Information System (INIS)

    Tan Xiangyu; Zhang Qiaogen; Wang Xiuhuan; Sun Fu; Zha Wei; Jia Zhijie

    2008-01-01

    A point-plane electrode system in atmospheric air is established to investigate the mechanism of the corona discharge. By using this system, the current pulses of the corona discharges under the 50 Hz ac voltage are measured using partial discharge (PD) measurement instrument and constitute the point-plane voltage-current (V-I) characteristic equation together with the voltage. Then, this paper constructs the nonlinear circuit model and differential equations of the system in an attempt to give the underlying dynamic mechanism based on the nonlinear V-I characteristics of the point-plane corona discharges. The results show that the chaotic phenomenon is found in the corona circuit by the experimental study and nonlinear dynamic analysis. The basic dynamic characteristics, including the Lyapunov exponent, the existence of the strange attractors, and the equilibrium points, are also found and analyzed in the development process of the corona circuit. Moreover, the time series of the corona current pulses obtained in the experiment is used to demonstrate the chaotic characteristics of the corona current based on the nonlinear dynamic circuit theory and the experimental basis. It is pointed out that the corona phenomenon is not a purely stochastic phenomenon but a short term deterministic chaotic activity

  13. Spectroscopic Study of Electrical Glow Discharges in Gases

    Science.gov (United States)

    Reyes, P. G.; Evangelista, M.; Trujillo, C.; Castillo, F.; Rangel, J.

    2006-12-01

    The variation of the power of the light emitted in a Glow Discharge in Gases of low pressure (GDGLP) excited by a DC source was studied. A lack of dependency of the kind of gas used and the pressure it is located at was obtained. This is comparable to the potential drop which takes place in the discharge by inelastic collisions such as ionization, recombination, excitation, relaxation, etc.

  14. Impact of partially treated sewage effluent on the water quality of ...

    African Journals Online (AJOL)

    Impact of partially treated sewage effluent on the water quality of recipient. Epie Creek in the Niger Delta area of Nigeria was investigated experimentally by analysing the physico-chemical and biological characteristics of the surface water samples collected at four (4) sampling stations: at the effluent discharge point (fall ...

  15. Numerical simulation of compact intracloud discharge and generated electromagnetic pulse

    Science.gov (United States)

    Babich, L. P.; Bochkov, E. I.; Kutsyk, I. M.

    2015-06-01

    Using the concept of the relativistic runaway electron avalanche, numerical simulation of compact intracloud discharge as a generator of powerful natural electromagnetic pulses (EMPs) in the HF-UHF range was conducted. We evaluated the numbers of electrons initiating the avalanche, with which the calculated EMP characteristics are consistent with measured ones. The discharge capable of generating EMPs produces runaway electrons in numbers close to those in the source of terrestrial γ-flashes (TGF) registered in the nearest space, which may be an argument for a joint EMP and TGF source.

  16. Soft x-ray amplification in an ablative capillary discharge

    International Nuclear Information System (INIS)

    Kwek, K.H.; Low, K.S.; Tan, C.A.; Lim, C.S.

    1999-01-01

    Soft x-ray amplification in CVI 18.2 nm line is observed in an ablative UHMW-PE capillary discharge. The gain coefficient is measured to be 1.9 cm -1 . The electron density is about 2 x 10 19 cm -3 . This indicates that capillary discharge pumping device can be a source for a compact soft x-ray laser. (author)

  17. Defocusing effects of lensless ghost imaging and ghost diffraction with partially coherent sources

    Science.gov (United States)

    Zhou, Shuang-Xi; Sheng, Wei; Bi, Yu-Bo; Luo, Chun-Ling

    2018-04-01

    The defocusing effect is inevitable and degrades the image quality in the conventional optical imaging process significantly due to the close confinement of the imaging lens. Based on classical optical coherent theory and linear algebra, we develop a unified formula to describe the defocusing effects of both lensless ghost imaging (LGI) and lensless ghost diffraction (LGD) systems with a partially coherent source. Numerical examples are given to illustrate the influence of defocusing length on the quality of LGI and LGD. We find that the defocusing effects of the test and reference paths in the LGI or LGD systems are entirely different, while the LGD system is more robust against defocusing than the LGI system. Specifically, we find that the imaging process for LGD systems can be viewed as pinhole imaging, which may find applications in ultra-short-wave band imaging without imaging lenses, e.g. x-ray diffraction and γ-ray imaging.

  18. Mercury-free discharges for lighting - editorial

    NARCIS (Netherlands)

    Haverlag, M.

    2007-01-01

    This special Cluster of articles in Journal of Physics D: Applied Physics covers the subject of mercury-free discharges that are being investigated by different light source researchers, as an alternative to existing mercury-containing lamps. The main driving force to move away from

  19. Electric probe data analysis for glow discharge diagnostics

    International Nuclear Information System (INIS)

    Cain, B.L.

    1987-01-01

    This report summarizes the development and application of digital computations for the analysis of data from an electric probe used for glow discharge diagnostics. The essential physics of the probe/discharge interaction is presented, along with formulations from modern electric probe theory. These results are then digitally implemented by a set of computer programs which both calculate discharge properties of electron temperature and density, and aid in the interpretation of these property estimates. The method of analysis, and the theories selected for implementation, are valid only for low pressure, collisionless sheath, and quiescent discharges where the single electric probe has a much smaller area than the discharge reference electrode. However, certain algorithms are included which, in some cases, can extend the analysis into intermediate pressure regimes. The digital programs' functional capabilities are demonstrated by the analysis of experimental probe data, collected using a laboratory glow discharge. Typical sources of error inherent in the electric probe method are discussed, along with an analysis of error induced by the computational methods of the programs. 27 refs., 49 figs., 20 tabs

  20. Electrolyte effects in a model of proton discharge on charged electrodes

    Science.gov (United States)

    Wiebe, Johannes; Kravchenko, Kateryna; Spohr, Eckhard

    2015-01-01

    We report results on the influence of NaCl electrolyte dissolved in water on proton discharge reactions from aqueous solution to charged platinum electrodes. We have extended a recently developed combined proton transfer/proton discharge model on the basis of empirical valence bond theory to include NaCl solutions with several different concentrations of cations and anions, both stoichiometric (1:1) compositions and non-stoichiometric ones with an excess of cations. The latter solutions partially screen the electrostatic potential from the surface charge of the negatively charged electrode. 500-1000 trajectories of a discharging proton were integrated by molecular dynamics simulations until discharge occurred, or for at most 1.5 ns. The results show a strong dependence on ionic strength, but only a weak dependence on the screening behavior, when comparing stoichiometric and non-stoichiometric solutions. Overall, the Na+ cations exert a more dominant effect on the discharge reaction, which we argue is likely due to the very rigid arrangements of the cations on the negatively polarized electrode surface. Thus, our model predicts, for the given and very high negative surface charge densities, the fastest discharge reaction for pure water, but obviously cannot take into account the fact that such high charge densities are even more out of reach experimentally than for higher electrolyte concentrations.

  1. UK strategy for radioactive discharges 2001-2020. Consultation document

    International Nuclear Information System (INIS)

    2000-06-01

    This consultation draft of a strategy for radioactive discharges describes how the United Kingdom (UK) will implement the agreements reached at the 1998 Ministerial meeting of the OSPAR Commission, with regard to radioactive substances. It also provides a policy base for future reviews of discharge authorisations by the regulatory bodies and for strategic planning by the nuclear operators. The strategy sets a framework for radioactive discharges from UK installations over the next twenty years. Its aims are: progressive and substantial reductions in radioactive discharges from the UK as a whole and from each of the main sectors responsible for such discharges; progressive reduction of human exposure to ionising radiation resulting from radioactive discharges, so that no member of the general public in the UK will be exposed to a dose of more than 0.02 mSv a year, as a result of authorised radioactive discharges made from 2020 onwards; progressive reductions in concentrations of radionuclides in the marine environment resulting from radioactive discharges, such that by 2020 they add close to zero to historic levels. The scope of the UK strategy encompasses radioactive discharges from nuclear licensed sites, defence activities and other nuclear and non-nuclear sources of radioactive discharges. It covers both liquid and aerial discharges, although it is assumed that in general liquid discharges will have the largest and most measurable effects in the marine environment

  2. Delineating Landfill Leachate Discharge To An Arsenic Contaminated Waterway

    Science.gov (United States)

    Discharge of contaminated ground water may serve as a primary and on-going source of contamination to surface water. A field investigation was conducted at a Superfund site in Massachusetts, USA to define the locus of contaminant flux and support source identification for arseni...

  3. Characterization of a dielectric barrier plasma gun discharging at atmospheric pressure

    International Nuclear Information System (INIS)

    Zhang Guangqiu; Ge Yuanjing; Zhang Yuefei; Chen Guangliang

    2004-01-01

    The authors develop a plasma gun based on dielectric barrier discharge and working at atmospheric pressure. A theoretical model to predict the gun discharge voltage is built, which is in agreement with the experimental results. After investigating the characterization of discharging gun and utilizing it for polymerization, authors find that the gun can be used as a source to generate a stable uniform plasma for different plasma-processing technologies. (author)

  4. A prototype of an electric-discharge gas flow oxygen−iodine laser: I. Modeling of the processes of singlet oxygen generation in a transverse cryogenic slab RF discharge

    Energy Technology Data Exchange (ETDEWEB)

    Vagin, N. P.; Ionin, A. A., E-mail: aion@sci.lebedev.ru; Kochetov, I. V.; Napartovich, A. P.; Sinitsyn, D. V., E-mail: dsinit@sci.lebedev.ru; Yuryshev, N. N. [Russian Academy of Sciences, Lebedev Physical Institute (Russian Federation)

    2017-03-15

    The existing kinetic model describing self-sustained and electroionization discharges in mixtures enriched with singlet oxygen has been modified to calculate the characteristics of a flow RF discharge in molecular oxygen and its mixtures with helium. The simulations were performed in the gas plug-flow approximation, i.e., the evolution of the plasma components during their motion along the channel was represented as their evolution in time. The calculations were carried out for the O{sub 2}: He = 1: 0, 1: 1, 1: 2, and 1: 3 mixtures at an oxygen partial pressure of 7.5 Torr. It is shown that, under these conditions, volumetric gas heating in a discharge in pure molecular oxygen prevails over gas cooling via heat conduction even at an electrode temperature as low as ~100 K. When molecular oxygen is diluted with helium, the behavior of the gas temperature changes substantially: heat removal begins to prevail over volumetric gas heating, and the gas temperature at the outlet of the discharge zone drops to ~220–230 K at room gas temperature at the inlet, which is very important in the context of achieving the generation threshold in an electric-discharge oxygen−iodine laser based on a slab cryogenic RF discharge.

  5. A prototype of an electric-discharge gas flow oxygen−iodine laser: I. Modeling of the processes of singlet oxygen generation in a transverse cryogenic slab RF discharge

    International Nuclear Information System (INIS)

    Vagin, N. P.; Ionin, A. A.; Kochetov, I. V.; Napartovich, A. P.; Sinitsyn, D. V.; Yuryshev, N. N.

    2017-01-01

    The existing kinetic model describing self-sustained and electroionization discharges in mixtures enriched with singlet oxygen has been modified to calculate the characteristics of a flow RF discharge in molecular oxygen and its mixtures with helium. The simulations were performed in the gas plug-flow approximation, i.e., the evolution of the plasma components during their motion along the channel was represented as their evolution in time. The calculations were carried out for the O 2 : He = 1: 0, 1: 1, 1: 2, and 1: 3 mixtures at an oxygen partial pressure of 7.5 Torr. It is shown that, under these conditions, volumetric gas heating in a discharge in pure molecular oxygen prevails over gas cooling via heat conduction even at an electrode temperature as low as ~100 K. When molecular oxygen is diluted with helium, the behavior of the gas temperature changes substantially: heat removal begins to prevail over volumetric gas heating, and the gas temperature at the outlet of the discharge zone drops to ~220–230 K at room gas temperature at the inlet, which is very important in the context of achieving the generation threshold in an electric-discharge oxygen−iodine laser based on a slab cryogenic RF discharge.

  6. Thermal mechanism of prepeak formation in Pulsed Glow Discharge

    Science.gov (United States)

    Voronov, Maxim; Hoffmann, Volker; Steingrobe, Tobias; Buscher, Wolfgang; Engelhard, Carsten; Storey, Andrew; Ray, Steven; Hieftje, Gary

    2012-10-01

    A microsecond Pulsed Glow Discharge (μs PGD) in a Grimm-type source is characterized by the so-called ``prepeak,'' which is a spike in both electrical current and emission intensity at the leading edge of the discharge pulse. The prepeak is followed by synchronized vibrations of the current and the emission. To understand the nature of these phenomena, a microphone was inserted into the discharge chamber. Acoustical waves were detected and found to be in correlation with the measured vibrations. This points to a thermal mechanism for prepeak formation: the gas is heated in the leading edge of the discharge pulse and then expanded. To prove this suggestion, a Monte-Carlo based model was developed to simulate the evolution of Ar concentration, temperature, and flow in time and space. Potentially, the model could be used for gas simulations in a wide range of different applications. Here, the model is incorporated into an existing but modified model of the μs PGD in a Grimm-type plasma excitation source. Results of the simulations confirm that the thermal mechanism is responsible for the formation of the electrical prepeak and the pressure waves.

  7. High pressure microwave discharge for electrodeless Xe-lamp

    International Nuclear Information System (INIS)

    Kudela, J.; Kando, M.

    1998-01-01

    Preliminary results are presented of the investigation into the high pressure Xe microwave discharge in bent tubes, sustained by electromagnetic surface wave. The research was aimed to help with the design of a new generation of high intensity light sources with generally more complex shapes than those commonly used. The results show that the electromagnetic surface wave can effectively sustain discharge in tubes with various bending radii within the large pressure range. The curved shapes of discharge tubes improve the cooling of the lamp which is one of the major technological difficulties. It was shown that under relatively lower powers and higher gas pressures (100 Torr) the discharge exhibits a streamer-like filamentation and the branching of filaments. The phenomena of the effective sustaining of the discharge by surface wave propagation along curved plasma columns will be investigated in more detail by measurements of the profiles of surface wave electric and magnetic field intensities. (author)

  8. Triggering Excimer Lasers by Photoionization from Corona Discharges

    Science.gov (United States)

    Xiong, Zhongmin; Duffey, Thomas; Brown, Daniel; Kushner, Mark

    2009-10-01

    High repetition rate ArF (192 nm) excimer lasers are used for photolithography sources in microelectronics fabrication. In highly attaching gas mixtures, preionization is critical to obtaining stable, reproducible glow discharges. Photoionization from a separate corona discharge is one technique for preionization which triggers the subsequent electron avalanche between the main electrodes. Photoionization triggering of an ArF excimer laser sustained in multi-atmosphere Ne/Ar/F2/Xe gas mixtures has been investigated using a 2-dimensional plasma hydrodynamics model including radiation transport. Continuity equations for charged and neutral species, and Poisson's equation are solved coincident with the electron temperature with transport coefficients obtained from solutions of Boltzmann's equation. Photoionizing radiation is produced by a surface discharge which propagates along a corona-bar located adjacent to the discharge electrodes. The consequences of pulse power waveform, corona bar location, capacitance and gas mixture on uniformity, symmetry and gain of the avalanche discharge will be discussed.

  9. Simulation of dust particles in dual-frequency capacitively coupled silane discharges

    International Nuclear Information System (INIS)

    Liu Xiangmei; Song Yuanhong; Xu Xiang; Wang Younian

    2010-01-01

    The behavior of nanoparticles in dual-frequency capacitively coupled silane discharges is investigated by employing a one-dimensional self-consistent fluid model. The numerical simulation tries to trace the formation, charging, growth, and transport of dust particles during the discharge, under the influences of the high- and low-frequency electric sources, as well as the gas pressure. The effects of the presence of the nanoparticles and larger anions on the plasma properties are also discussed, especially, for the bulk potential, electron temperature, and densities of various particles. The calculation results show that the nanoparticle density and charge distribution are mainly influenced by the voltage and frequency of the high-frequency source, while the voltage of the low-frequency source can also exert an effect on the nanoparticle formation, compared with the frequency. As the discharge lasts, the electric potential and electron density keep decreasing, while the electron temperature gets increasing after a sudden drop.

  10. Numerical simulation of narrow bipolar electromagnetic pulses generated by thunderstorm discharges

    Science.gov (United States)

    Bochkov, E. I.; Babich, L. P.; Kutsyk, I. M.

    2013-07-01

    Using the concept of avalanche relativistic runaway electrons (REs), we perform numerical simulations of compact intracloud discharge (CID) as a generator of powerful natural electromagnetic pulses (EMPs) in the HF-VHF range, called narrow bipolar pulses (NBPs). For several values of the field overvoltage and altitude at which the discharge develops, the numbers of seed electrons initiating the avalanche are evaluated, with which the calculated EMP characteristics are consistent with the measured NBP parameters. We note shortcomings in the hypothesis assuming participation of cosmic ray air showers in avalanche initiation. The discharge capable of generating NBPs produces REs in numbers close to those in the source of terrestrial γ-ray flashes (TGFs), which can be an argument in favor of a unified NBP and TGF source.

  11. Numerical simulation of narrow bipolar electromagnetic pulses generated by thunderstorm discharges

    International Nuclear Information System (INIS)

    Bochkov, E. I.; Babich, L. P.; Kutsyk, I. M.

    2013-01-01

    Using the concept of avalanche relativistic runaway electrons (REs), we perform numerical simulations of compact intracloud discharge (CID) as a generator of powerful natural electromagnetic pulses (EMPs) in the HF-VHF range, called narrow bipolar pulses (NBPs). For several values of the field overvoltage and altitude at which the discharge develops, the numbers of seed electrons initiating the avalanche are evaluated, with which the calculated EMP characteristics are consistent with the measured NBP parameters. We note shortcomings in the hypothesis assuming participation of cosmic ray air showers in avalanche initiation. The discharge capable of generating NBPs produces REs in numbers close to those in the source of terrestrial γ-ray flashes (TGFs), which can be an argument in favor of a unified NBP and TGF source

  12. New developments in glow discharge optical emission and mass spectrometry

    International Nuclear Information System (INIS)

    Hoffmann, Volker; Dorka, Roland; Wilken, Ludger; Wetzig, Klaus

    2000-01-01

    This paper describes new developments in flow discharge optical emission (GD-OES) and mass spectrometry (GD-MS) at IFW and presents corresponding new applications (analysis of microelectronic multi-layer system by radio frequency glow discharge optical emission spectrometry (RF-GD-OES) and analysis of pure iron by a new Grimm-type GD-MS source)

  13. Fast Partial Evaluation of Pattern Matching in Strings

    DEFF Research Database (Denmark)

    Ager, Mads Sig; Danvy, Olivier; Rohde, Henning Korsholm

    2006-01-01

    We show how to obtain all of Knuth, Morris, and Pratt's linear-time string matcher by specializing a quadratic-time string matcher with respect to a pattern string. Although it has been known for 15 years how to obtain this linear matcher by partial evaluation of a quadratic one, how to obtain...... it in linear time has remained an open problem. Obtaining a linear matcher by partial evaluation of a quadratic one is achieved by performing its backtracking at specialization time and memoizing its results. We show (1) how to rewrite the source matcher such that its static intermediate computations can...... be shared at specialization time and (2) how to extend the memoization capabilities of a partial evaluator to static functions. Such an extended partial evaluator, if its memoization is implemented efficiently, specializes the rewritten source matcher in linear time. Finally, we show that the method also...

  14. Fast Partial Evaluation of Pattern Matching in Strings

    DEFF Research Database (Denmark)

    Ager, Mads Sig; Danvy, Olivier; Rohde, Henning Korsholm

    2003-01-01

    We show how to obtain all of Knuth, Morris, and Pratt's linear-time string matcher by specializing a quadratic-time string matcher with respect to a pattern string. Although it has been known for 15 years how to obtain this linear matcher by partial evaluation of a quadratic one, how to obtain...... it in linear time has remained an open problem. Obtaining a linear matcher by partial evaluation of a quadratic one is achieved by performing its backtracking at specialization time and memoizing its results. We show (1) how to rewrite the source matcher such that its static intermediate computations can...... be shared at specialization time and (2) how to extend the memoization capabilities of a partial evaluator to static functions. Such an extended partial evaluator, if its memoization is implemented efficiently, specializes the rewritten source matcher in linear time. Finally, we show that the method also...

  15. Impacts of urban wastewater discharge on seagrass meadows ( Zostera noltii)

    Science.gov (United States)

    Cabaço, Susana; Machás, Raquel; Vieira, Vasco; Santos, Rui

    2008-06-01

    The abiotic disturbance of urban wastewater discharge and its effects in the population structure, plant morphology, leaf nutrient content, epiphyte load and macroalgae abundance of Zostera noltii meadows were investigated in Ria Formosa coastal lagoon, southern Portugal using both univariate and multivariate analysis. Four sites were assessed, on a seasonal basis, along a gradient from a major Waste Water Treatment Works (WWTW) discharge to a main navigation channel. The wastewater discharge caused an evident environmental disturbance through the nutrient enrichment of the water and sediment, particularly of ammonium. Zostera noltii of the sites closest to the nutrient source showed higher leaf N content, clearly reflecting the nitrogen load. The anthropogenic nutrient enrichment resulted in higher biomass, and higher leaf and internode length, except for the meadow closest to the wastewater discharge (270 m). The high ammonium concentration (158-663 μM) in the water at this site resulted in the decrease of biomass, and both the leaf and internode length, suggesting a toxic effect on Z. noltii. The higher abundance of macroalgae and epiphytes found in the meadow closest to the nutrient source may also affect the species negatively. Shoot density was higher at the nutrient-undisturbed site. Two of the three abiotic processes revealed by Principal Component Analysis were clearly related to the WWTW discharge, a contrast between water column salinity and nutrient concentration and a sediment contrast between both porewater nutrients and temperature and redox potential. A multiple regression analysis showed that these abiotic processes had a significant effect on the biomass-density dynamics of meadows and on the overall size of Z. noltii plants, respectively. Results show that the wastewater discharge is an important source of environmental disturbance and nutrients availability in Ria Formosa lagoon affecting the population structure, morphology and N content of Z

  16. Investigation of slot discharge on a 239 MVA hydro generator stator winding

    Energy Technology Data Exchange (ETDEWEB)

    Li, S.; Hong, W. [BC Hydro and Power Authority, Vancouver, BC (Canada)

    2009-07-01

    This paper discussed a slot discharge investigation conducted on a 239 MVA generator stator winding. The generator in which the winding was located had experienced core split distortion, stator winding phase-to-phase failures, winding failures during Hipot testing, and high partial discharge (PD) activity. The results of on-line PD testing data were evaluated. The stator winding was subjected to visual inspections, bar dissections, and failure mechanism analyses. Eleven winding bars were removed from the stator slots in order to assess groundwall insulation conditions and identify the cause of the slot discharge activity. It was determined that the root cause of the slot discharge was a loose, non-uniform bar in the slot. The vibrating bar caused the semi-conductive coating to wear out and degraded the armour tape. Results of the study demonstrated the importance of on-line PD monitoring for detecting slot PD activity. 4 refs., 3 tabs., 11 figs.

  17. A study on prevention of an electric discharge at an extraction electrode of an electron cyclotron resonance ion source for cancer therapy.

    Science.gov (United States)

    Kishii, Y; Kawasaki, S; Kitagawa, A; Muramatsu, M; Uchida, T

    2014-02-01

    A compact ECR ion source has utilized for carbon radiotherapy. In order to increase beam intensity with higher electric field at the extraction electrode and be better ion supply stability for long periods, electric geometry and surface conditions of an extraction electrode have been studied. Focusing attention on black deposited substances on the extraction electrode, which were observed around the extraction electrode after long-term use, the relation between black deposited substances and the electrical insulation property is investigated. The black deposited substances were inspected for the thickness of deposit, surface roughness, structural arrangement examined using Raman spectroscopy, and characteristics of electric discharge in a test bench, which was set up to simulate the ECR ion source.

  18. The source, discharge, and chemical characteristics of selected springs, and the abundance and health of associated endemic anuran species in the Mojave network parks

    Science.gov (United States)

    Schroeder, Roy A.; Smith, Gregory A.; Martin, Peter; Flint, Alan L.; Gallegos, Elizabeth; Fisher, Robert N.; Martin, Peter; Schroeder, Roy A.

    2015-01-01

    Hydrological and biological investigations were done during 2005 and 2006 in cooperation with the U.S. National Park Service to investigate the source, discharge, and chemical characteristics of selected springs and the abundance and health of endemic anuran (frog and toad) species at Darwin Falls in Death Valley National Park, Piute Spring in Mojave National Preserve, and Fortynine Palms Oasis in Joshua Tree National Park. Discharge from the springs at these sites sustains isolated riparian habitats in the normally dry Mojave Desert. Data were collected on water quantity (discharge) and quality, air and water temperature, and abundance and health of endemic anuran species. In addition, a single survey of the abundance and health of endemic anuran species was completed at Rattlesnake Canyon in Joshua Tree National Park. Results from this study were compared to limited historical data, where they exist, and can provide a baseline for future hydrological and biological investigations to evaluate the health and sustainability of the resource and its response to changing climate and increasing human use.

  19. Charge Management in LISA Pathfinder: The Continuous Discharging Experiment

    Science.gov (United States)

    Ewing, Becca Elizabeth

    2018-01-01

    Test mass charging is a significant source of excess force and force noise in LISA Pathfinder (LPF). The planned design scheme for mitigation of charge induced force noise in LISA is a continuous discharge by UV light illumination. We report on analysis of a charge management experiment on-board LPF conducted during December 2016. We discuss the measurement of test mass charging noise with and without continuous UV illumination, in addition to the dynamic response in the continuous discharge scheme. Results of the continuous discharge system will be discussed for their application to operating LISA with lower test mass charge.

  20. Regulating manure application discharges from concentrated animal feeding operations in the United States

    International Nuclear Information System (INIS)

    Centner, Terence J.; Feitshans, Theodore A.

    2006-01-01

    In the United States, reducing pollution from agriculture has received attention due to data suggesting that this is the leading source of impairment of many waterbodies. The federal government revised its regulations governing concentrated animal feeding operations (CAFOs) to enhance governmental oversight over sources of pollution. For the application of manure resulting in pollutant discharges, CAFOs need to implement nutrient management plans. A federal court affirmed the ability of the US federal government to oversee the application of manure from CAFOs that have discharges. Simultaneously, owners and operators of CAFOs who have implemented an appropriate nutrient management plan may forgo securing a permit if their discharges qualify under the agricultural stormwater discharge exemption. - New rules applying to the application of manure by large concentrated animal feeding operations should reduce water contamination

  1. Design and Validation of an Open-Source, Partial Task Trainer for Endonasal Neuro-Endoscopic Skills Development: Indian Experience.

    Science.gov (United States)

    Singh, Ramandeep; Baby, Britty; Damodaran, Natesan; Srivastav, Vinkle; Suri, Ashish; Banerjee, Subhashis; Kumar, Subodh; Kalra, Prem; Prasad, Sanjiva; Paul, Kolin; Anand, Sneh; Kumar, Sanjeev; Dhiman, Varun; Ben-Israel, David; Kapoor, Kulwant Singh

    2016-02-01

    Box trainers are ideal simulators, given they are inexpensive, accessible, and use appropriate fidelity. The development and validation of an open-source, partial task simulator that teaches the fundamental skills necessary for endonasal skull-base neuro-endoscopic surgery. We defined the Neuro-Endo-Trainer (NET) SkullBase-Task-GraspPickPlace with an activity area by analyzing the computed tomography scans of 15 adult patients with sellar suprasellar parasellar tumors. Four groups of participants (Group E, n = 4: expert neuroendoscopists; Group N, n =19: novice neurosurgeons; Group R, n = 11: neurosurgery residents with multiple iterations; and Group T, n = 27: neurosurgery residents with single iteration) performed grasp, pick, and place tasks using NET and were graded on task completion time and skills assessment scale score. Group E had lower task completion times and greater skills assessment scale scores than both Group N and R (P ≤ 0.03, 0.001). The performance of Groups N and R was found to be equivalent; in self-assessing neuro-endoscopic skill, the participants in these groups were found to have equally low pretraining scores (4/10) with significant improvement shown after NET simulation (6, 7 respectively). Angled scopes resulted in decreased scores with tilted plates compared with straight plates (30° P ≤ 0.04, 45° P ≤ 0.001). With tilted plates, decreased scores were observed when we compared the 0° with 45° endoscope (right, P ≤ 0.008; left, P ≤ 0.002). The NET, a face and construct valid open-source partial task neuroendoscopic trainer, was designed. Presimulation novice neurosurgeons and neurosurgical residents were described as having insufficient skills and preparation to practice neuro-endoscopy. Plate tilt and endoscope angle were shown to be important factors in participant performance. The NET was found to be a useful partial-task trainer for skill building in neuro-endoscopy. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Evaluation of thermal stress in the anode chamber wall of a large volume magnetic bucket ion source

    International Nuclear Information System (INIS)

    Wells, Russell; Horiike, Hiroshi; Kuriyama, Masaaki; Ohara, Yoshihiro

    1984-02-01

    Thermal stress analysis was performed on the plasma chamber of the Large Volume Magnetic Multipole Bucket Ion Source (LVB) designed for use on the JT-60 NBI system. The energy absorbed by the walls of the plasma chambers of neutral beam injectors is of the order of 1% of the accelerator electrical drain power. A previous study indicates that a moderately high heat flux, of about 600W/cm 2 , is concentrated on the magnetic field cusp lines during normal full power operation. Abnormal arc discharges during conditioning of a stainless steel LVB produced localized melting of the stainless steel at several locations near the cusps lines. The power contained in abnormal arc discharges (arc spots) was estimated from the observed melting. Thermal stress analysis was performed numerically on representative sections of the copper LVB design for both stable and abnormal arc discharge conditions. Results show that this chamber should not fail due to thermal fatigue stesses arising from normal arc discharges. However, fatigue failure may occur after several hundred to a few thousand arc spots of 30mS duration at any one location. Limited arc discharge operation of the copper bucket was performed to partially verify the chamber's durability. (author)

  3. Plasma rotation by electric and magnetic fields in a discharge cylinder

    Science.gov (United States)

    Wilhelm, H. E.; Hong, S. H.

    1977-01-01

    A theoretical model for an electric discharge consisting of a spatially diverging plasma sustained electrically between a small ring cathode and a larger ring anode in a cylindrical chamber with an axial magnetic field is developed to study the rotation of the discharge plasma in the crossed electric and magnetic fields. The associated boundary-value problem for the coupled partial differential equations which describe the electric potential and the plasma velocity fields is solved in closed form. The electric field, current density, and velocity distributions are discussed in terms of the Hartmann number and the Hall coefficient. As a result of Lorentz forces, the plasma rotates with speeds as high as 1 million cm/sec around its axis of symmetry at typical conditions. As an application, it is noted that rotating discharges of this type could be used to develop a high-density plasma-ultracentrifuge driven by j x B forces, in which the lighter (heavier) ion and atom components would be enriched in (off) the center of the discharge cylinder.

  4. Analysis of the Sensitivity of K-Type Molecular Sieve-Deposited MWNTs for the Detection of SF6 Decomposition Gases under Partial Discharge

    Science.gov (United States)

    Zhang, Xiaoxing; Li, Xin; Luo, Chenchen; Dong, Xingchen; Zhou, Lei

    2015-01-01

    Sulfur hexafluoride (SF6) is widely utilized in gas-insulated switchgear (GIS). However, part of SF6 decomposes into different components under partial discharge (PD) conditions. Previous research has shown that the gas responses of intrinsic and 4 Å-type molecular sieve-deposited multi-wall carbon nanotubes (MWNTs) to SOF2 and SO2F2, two important decomposition components of SF6, are not obvious. In this study, a K-type molecular sieve-deposited MWNTs sensor was developed. Its gas response characteristics and the influence of the mixture ratios of gases on the gas-sensing properties were studied. The results showed that, for sensors with gas mixture ratios of 5:1, 10:1, and 20:1, the resistance change rate increased by nearly 13.0% after SOF2 adsorption, almost 10 times that of MWNTs sensors, while the sensors’ resistance change rate with a mixture ratio of 10:1 reached 17.3% after SO2F2 adsorption, nearly nine times that of intrinsic MWNT sensors. Besides, a good linear relationship was observed between concentration of decomposition components and the resistance change rate of sensors. PMID:26569245

  5. Analysis of the Sensitivity of K-Type Molecular Sieve-Deposited MWNTs for the Detection of SF6 Decomposition Gases under Partial Discharge

    Directory of Open Access Journals (Sweden)

    Xiaoxing Zhang

    2015-11-01

    Full Text Available Sulfur hexafluoride (SF6 is widely utilized in gas-insulated switchgear (GIS. However, part of SF6 decomposes into different components under partial discharge (PD conditions. Previous research has shown that the gas responses of intrinsic and 4 Å-type molecular sieve-deposited multi-wall carbon nanotubes (MWNTs to SOF2 and SO2F2, two important decomposition components of SF6, are not obvious. In this study, a K-type molecular sieve-deposited MWNTs sensor was developed. Its gas response characteristics and the influence of the mixture ratios of gases on the gas-sensing properties were studied. The results showed that, for sensors with gas mixture ratios of 5:1, 10:1, and 20:1, the resistance change rate increased by nearly 13.0% after SOF2 adsorption, almost 10 times that of MWNTs sensors, while the sensors’ resistance change rate with a mixture ratio of 10:1 reached 17.3% after SO2F2 adsorption, nearly nine times that of intrinsic MWNT sensors. Besides, a good linear relationship was observed between concentration of decomposition components and the resistance change rate of sensors.

  6. Wastewater discharge impact on drinking water sources along the Yangtze River (China).

    Science.gov (United States)

    Wang, Zhuomin; Shao, Dongguo; Westerhoff, Paul

    2017-12-01

    Unplanned indirect (de facto) wastewater reuse occurs when wastewater is discharged into surface waters upstream of potable drinking water treatment plant intakes. This paper aims to predict percentages and trends of de facto reuse throughout the Yangtze River watershed in order to understand the relative contribution of wastewater discharges into the river and its tributaries towards averting water scarcity concerns. The Yangtze River is the third longest in the world and supports more than 1/15 of the world's population, yet the importance of wastewater on the river remains ill-defined. Municipal wastewater produced in the Yangtze River Basin increased by 41% between 1998 and 2014, from 2580m 3 /s to 3646m 3 /s. Under low flow conditions in the Yangtze River near Shanghai, treated wastewater contributions to river flows increased from 8% in 1998 to 14% in 2014. The highest levels of de facto reuse appeared along a major tributary (Han River) of the Yangtze River, where de facto reuse can exceed 20%. While this initial analysis of de facto reuse used water supply and wastewater data from 110 cities in the basin and 11 gauging stations with >50years of historic streamflow data, the outcome was limited by the lack of gauging stations at more locations (i.e., data had to be predicted using digital elevation mapping) and lack of precise geospatial location of drinking water intakes or wastewater discharges. This limited the predictive capability of the model relative to larger datasets available in other countries (e.g., USA). This assessment is the first analysis of de facto wastewater reuse in the Yangtze River Basin. It will help identify sections of the river at higher risk for wastewater-related pollutants due to presence of-and reliance on-wastewater discharge that could be the focus of field studies and model predictions of higher spatial and temporal resolution. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Effect of air-water mixture drawoff from condenser discharge chamberson the Chernobylsk NPP turbine operating efficiency

    International Nuclear Information System (INIS)

    Trushin, V.N.; Aleksandrov, I.P.; Borets, V.I.

    1985-01-01

    It is established experimentally that reliable operation of air drawoffs from conden.ser discharge chambers influences greatly on efficiency of a cooling system of low-pressure condensers (LPC). The interacting influence of drawoff lines operating in parallel is outlined, which may, under certain conditions, lead to partial or total neutralization of the drawoff system, that, in its turn, leads to formation of a unique waterfall flow regime in the discharge chamber of LPC outside its partition. Waterfall regime leads to reduction of cooling water flow rate, to partial uncovering of. the fuel element cluster with the proper fall of vacuum and turbine efficiency. Experimental investigations, carried out at a condenser model, permit to find a way and give recommendations to prevent the formation of waterfall regime of outflow

  8. Redox reactions with empirical potentials: atomistic battery discharge simulations.

    Science.gov (United States)

    Dapp, Wolf B; Müser, Martin H

    2013-08-14

    Batteries are pivotal components in overcoming some of today's greatest technological challenges. Yet to date there is no self-consistent atomistic description of a complete battery. We take first steps toward modeling of a battery as a whole microscopically. Our focus lies on phenomena occurring at the electrode-electrolyte interface which are not easily studied with other methods. We use the redox split-charge equilibration (redoxSQE) method that assigns a discrete ionization state to each atom. Along with exchanging partial charges across bonds, atoms can swap integer charges. With redoxSQE we study the discharge behavior of a nano-battery, and demonstrate that this reproduces the generic properties of a macroscopic battery qualitatively. Examples are the dependence of the battery's capacity on temperature and discharge rate, as well as performance degradation upon recharge.

  9. Fast imaging of intermittent electrospraying of water with positive corona discharge

    International Nuclear Information System (INIS)

    Pongrác, B; Janda, M; Martišovitš, V; Machala, Z; Kim, H H

    2014-01-01

    The effect of the electrospraying of water in combination with a positive direct current (dc) streamer corona discharge generated in air was investigated in this paper. We employed high-speed camera visualizations and oscilloscopic discharge current measurements in combination with an intensified charge-coupled device camera for fast time-resolved imaging. The repetitive process of Taylor cone formation and droplet formation from the mass fragments of water during the electrospray was visualized. Depending on the applied voltage, the following intermittent modes of electrospraying typical for water were observed: dripping mode, spindle mode, and oscillating-spindle mode. The observed electrospraying modes were repetitive with a frequency of a few hundreds of Hz, as measured from the fast image sequences. This frequency agreed well with the frequency of the measured streamer current pulses. The presence of filamentary streamer discharges at relatively low voltages probably prevented the establishment of a continuous electrospray in the cone–jet mode. After each streamer, a positive glow corona discharge was established on the water filament tip, and it propagated from the stressed electrode along with the water filament elongation. The results show a reciprocal character of intermittent electrospraying of water, and the presence of corona discharge, where both the electrospray and the discharge affect each other. The generation of a corona discharge from the water cone depended on the repetitive process of the cone formation. Also, the propagation and curvature of the water filament were influenced by the discharge and its resultant space charge. Furthermore, these phenomena were partially influenced by the water conductivity. (paper)

  10. Control of hydrocarbon radicals and film deposition by using an RF Whistler wave discharge

    International Nuclear Information System (INIS)

    Mieno, Tetsu; Shoji, Tatsuo; Kadota, Kiyoshi.

    1991-10-01

    Production of hydrocarbon radicals is controlled by using an RF Whistler wave discharge in a low pressure region (∼0.1 Pa). Plasma density of 10 10 - 10 13 cm -3 , electron temperature of 2-20 eV is obtained for the discharge of admixture of Ar and small content of source gases (CH 4 , C 2 H 2 , CO). Spectroscopic measurement indicates that densities of CH and H radicals and deposition rate of amorphous carbon:H film increase with electron density, electron temperature and source gas pressure. The etching effect of H atoms influences on the deposition rate and a high deposition rate (90 μm/hr for CO/Ar discharge) is obtained even in a low neutral pressure discharge. (author)

  11. Characterization of DBD plasma source for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Kuchenbecker, M; Vioel, W [University of Applied Sciences and Arts, Faculty of Natural Sciences and Technology, Von-Ossietzky-Str. 99, 37085 Goettingen (Germany); Bibinov, N; Awakowicz, P [Institute for Electrical Engineering and Plasma Technology, Ruhr-Universitaet Bochum, Universitaetstr. 150, 44780 Bochum (Germany); Kaemlimg, A; Wandke, D, E-mail: m.kuchenbecker@web.d, E-mail: Nikita.Bibinov@rub.d, E-mail: awakowicz@aept-ruhr-uni-bochum.d, E-mail: vioel@hawk-hhg.d [CINOGY GmbH, Max-Naeder-Str. 15, 37114 Duderstadt (Germany)

    2009-02-21

    The dielectric barrier discharge (DBD) plasma source for biomedical application is characterized using optical emission spectroscopy, plasma-chemical simulation and voltage-current measurements. This plasma source possesses only one electrode covered by ceramic. Human body or some other object with enough high electric capacitance or connected to ground can serve as the opposite electrode. DBD consists of a number of microdischarge channels distributed in the gas gap between the electrodes and on the surface of the dielectric. To characterize the plasma conditions in the DBD source, an aluminium plate is used as an opposite electrode. Electric parameters, the diameter of microdischarge channel and plasma parameters (electron distribution function and electron density) are determined. The gas temperature is measured in the microdischarge channel and calculated in afterglow phase. The heating of the opposite electrode is studied using probe measurement. The gas and plasma parameters in the microdischarge channel are studied at varied distances between electrodes. According to an energy balance study, the input microdischarge electric energy dissipates mainly in heating of electrodes (about 90%) and partially (about 10%) in the production of chemical active species (atoms and metastable molecules).

  12. Pancreatitis - discharge

    Science.gov (United States)

    Chronic pancreatitis - discharge; Pancreatitis - chronic - discharge; Pancreatic insufficiency - discharge; Acute pancreatitis - discharge ... You were in the hospital because you have pancreatitis. This is a swelling of the pancreas. You ...

  13. Fluid model of dc glow discharge with nonlocal ionization source term

    International Nuclear Information System (INIS)

    Rafatov, I R; Bogdanov, E A; Kudryavtsev, A A

    2012-01-01

    We developed and tested a simple hybrid model for a glow discharge, which incorporates nonlocal ionization by fast electrons into the fluid framework. Calculations have been performed for an argon gas. Comparison with the experimental data as well as with the hybrid (particle) and fluid modelling results demonstated good applicability of the proposed model.

  14. factors associated with discharge against medical advice among

    African Journals Online (AJOL)

    Hospital environmental factors have a significant relationship with discharge against medical advice. A similar study ..... contractors, and by reinforcing the infection control committee this will .... Sources: Field survey, 2015. The results in Table ...

  15. Length of stay after vaginal birth: sociodemographic and readiness-for-discharge factors.

    Science.gov (United States)

    Weiss, Marianne; Ryan, Polly; Lokken, Lisa; Nelson, Magdalen

    2004-06-01

    The impact of reductions in postpartum length of stay have been widely reported, but factors influencing length of hospital stay after vaginal birth have received less attention. The study purpose was to compare the sociodemographic characteristics and readiness for discharge of new mothers and their newborns at 3 discharge time intervals, and to determine which variables were associated with postpartum length of stay. The study sample comprised 1,192 mothers who were discharged within 2 postpartum days after uncomplicated vaginal birth at a tertiary perinatal center in the midwestern United States. The sample was divided into 3 postpartum length-of-stay groups: group 1 (18-30 hr), group 2 (31-42 hr), and group 3 (43-54 hr). Sociodemographic and readiness-for-discharge data were collected by self-report and from a computerized hospital information system. Measures of readiness for discharge included perceived readiness (single item and Readiness for Discharge After Birth Scale), documented maternal and neonatal clinical problems, and feeding method. Compared with other groups, the longest length-of-stay group was older; of higher socioeconomic status and education; and with more primiparous, breastfeeding, white, married mothers who were living with the baby's father, had adequate home help, and had a private payor source. This group also reported greater readiness for discharge, but their newborns had more documented clinical problems during the postbirth hospitalization. In logistic regression modeling, earlier discharge was associated with young age, multiparity, public payor source, low socioeconomic status, lack of readiness for discharge, bottle-feeding, and absence of a neonatal clinical problem. Sociodemographic characteristics and readiness for discharge (clinical and perceived) were associated with length of postpartum hospital stay. Length of stay is an outcome of a complex interface between patient, provider, and payor influences on discharge timing

  16. Gas discharge ion source. II. Duopigatron

    International Nuclear Information System (INIS)

    Bacon, F.M.; Bickes, R.W. Jr.; O'Hagan, J.B.

    1978-01-01

    Ion source performance characteristics consisting of total ion current, ion energy distribution, mass distribution, and ion current density distribution have been measured for several models of a duopigatron. Variations on the duopigatron design involved plasma expansion cup material and dimensions, secondary cathode material, and interelectrode spacings. Of the designs tested, the one with a copper and molybdenum secondary cathode, and a mild steel plasma expansion cup proved to give the best results. The ion current density distribution was peaked at the center of the plasma expansion cup and fell off to 80% of the peak value at the cup wall for a cup 15.2 mm deep. A total ion current of 180 mA consisting of 60%-70% atomic ions was produced with an arc current of 20 A and source pressure of 9.3 Pa. More shallow cups produced a larger beam current and a more sharply peaked ion current density distribution. Typical ion energy distributions were bellshaped curves with a peak 10-20 V below anode potential and with ion energies extending 30-40 V on either side of the peak

  17. Partial dynamical systems, fell bundles and applications

    CERN Document Server

    Exel, Ruy

    2017-01-01

    Partial dynamical systems, originally developed as a tool to study algebras of operators in Hilbert spaces, has recently become an important branch of algebra. Its most powerful results allow for understanding structural properties of algebras, both in the purely algebraic and in the C*-contexts, in terms of the dynamical properties of certain systems which are often hiding behind algebraic structures. The first indication that the study of an algebra using partial dynamical systems may be helpful is the presence of a grading. While the usual theory of graded algebras often requires gradings to be saturated, the theory of partial dynamical systems is especially well suited to treat nonsaturated graded algebras which are in fact the source of the notion of "partiality". One of the main results of the book states that every graded algebra satisfying suitable conditions may be reconstructed from a partial dynamical system via a process called the partial crossed product. Running in parallel with partial dynamica...

  18. Spectroscopic measurements of an H- ion source discharge

    International Nuclear Information System (INIS)

    Keller, R.; Smith, H.V. Jr.

    1985-01-01

    Spectral emission lines from an H - Penning surface-plasma source (SPS), the 4X source, are examined in the visible and near ultraviolet. Electron distribution temperatures are deduced from integral line-strength measurements. These temperatures are surprisingly low, about 0.5 eV. Electron density values of about 1.5 x 10 14 cm -3 and H-atom energies between 2 and 2.6 eV are determined from the measured Balmer-line profiles. Assuming the H - energy is identical to the H-atom energy, an emittance limit of 0.006 π x cm x mrad is deduced for this source with a 5.4-mm aperture

  19. Heart pacemaker - discharge

    Science.gov (United States)

    Cardiac pacemaker implantation - discharge; Artificial pacemaker - discharge; Permanent pacemaker - discharge; Internal pacemaker - discharge; Cardiac resynchronization therapy - discharge; CRT - discharge; ...

  20. Gas discharge ion source. I. Duoplasmatron

    International Nuclear Information System (INIS)

    Bacon, F.M.

    1978-01-01

    The effects of the plasma expansion cup on the operation of a duoplasmatron ion source have been investigated by measuring the total ion current and the distributions of the ion energy, mass, and current density. A copper expansion cup did not affect the magnetic field near the anode of the ion source and consequently the ion current density distribution was sharply peaked near the center of the cup. Ion energy distributions were approximately symmetrical about anode potential. The dominant ionic species were D + 3 and D + at low and high arc currents, respectively. Changes in the electrical potential of the copper cup with respect to the anode produced negligible changes in the above data. A mild steel plasma expansion cup caused the magnetic field to diverge and intercept the cup walls, resulting in ion current density distributions that were flatter and more amenable to focusing than the ones with the copper cup. With the steel cup at anode potential, the ion mass distribution was similar to that from the copper cup; however, the ion energy distribution was asymmetrical about the anode potential with a peak about 10-20 V above anode potential. The total ion current from this mode of operation was about one-third the value from the copper cup. If the steel cup assumed floating potential, about 50 V below anode potential, the total current increased to the level observed from the copper cup and the ion energy distribution was similar to that observed with the copper cup but the current density distribution was much flatter than that of the copper cup. The ion mass distribution was 60%-70% atomic ions over the entire arc current range investigated. Based on these data, a modified plasma expansion cup was designed with tapered steel walls lined with a boron nitride insert. The overall performance of the duoplasmatron ion source with this cup was superior to any of the previous three modes of operation

  1. Plasma Ion Source with an Internal Evaporator

    International Nuclear Information System (INIS)

    Turek, M.; Drozdziel, A.; Pyszniak, K.; Prucnal, S.; Maczka, D.

    2011-01-01

    A new construction of a hollow cathode ion source equipped with an internal evaporator heated by a spiral cathode filament and arc discharge is presented. The source is especially suitable for production of ions from solids. The proximity of arc discharge region and extraction opening enables production of intense ion beams even for very low discharge current (I a = 1.2 A). The currents of 50 μA (Al + ) and 70 μA (Bi + ) were obtained using the extraction voltage of 25 kV. The source is able to work for several tens of hours without maintenance breaks, giving possibility of high dose implantations. The paper presents the detailed description of the ion source as well as its experimental characteristics like dependences of extracted currents and anode voltage on anode and cathode currents. (author)

  2. Electric discharge synthesis of HCN in simulated Jovian atmospheres

    Science.gov (United States)

    Stribling, Roscoe; Miller, Stanley L.

    1987-01-01

    Corona discharge is presently considered as a possible source of the HCN detected in the Jovian atmosphere at 2.2 x 10 to the -7th moles/sq cm column density, for the cases of gas mixtures containing H2, CH4, and NH3, with H2/CH4 ratios from 4.4 to 1585. A 3:1 ratio of corona discharge to lightning energy similar to that of the earth is applied to Jupiter. Depending on the lightning energy available on Jupiter and the eddy diffusion coefficients in the synthesis region, HCN column densities generated by corona discharge could account for about 10 percent of the HCN observed.

  3. Complete destructive interference of partially coherent fields

    NARCIS (Netherlands)

    Gbur, G.J.; Visser, T.D.; Wolf, E.

    2004-01-01

    A three-point source model is used to study the interference of wavefields which are mutually partially coherent. It is shown that complete destructive interference of the fields is possible in such a "three-pinhole interferometer" even if the sources are not fully coherent with respect to each

  4. CT-guided thermoplastic assisted segmentectomy is an optimal breast conserving surgery for breast cancer with nipple discharge

    International Nuclear Information System (INIS)

    Makita, Masujiro; Gomi, Naoya; Tachikawa, Tomohiro

    2004-01-01

    Improvement of imaging by injecting contrast agents into the discharging duct and immobilizing the breast mound with a drape-type thermoplastic shell in breast conserving surgery was assessed by evaluating 96 cases of breast cancer patients with nipple discharge treated by partial mastectomy between April 1998 and August 2003. These patients were divided to three groups: Group A was treated by ordinary partial mastectomy or microdochectomy without new methods. Group B underwent contrast imaging without shell immobilization, and Group C received both shell immobilization and contrast imaging. The negative rates of surgical margins in Groups A, B and C were 19.0%, 17.2%, and 37.5%, respectively. The rates of negative ''lateral'' surgical margins in Groups A, B and C were 23.8%, 27.6%, and 50%, respectively. The rate of negative ''lateral'' surgical margins in Group C was significantly higher than that in Group A. Our findings suggest CT-guided thermoplastic assisted segmentectomy, adopting both ductography CT and immobilization by shell, is an optimal breast conserving surgery for breast cancer with nipple discharge. (author)

  5. Simulation on Change Law of Runoff, Sediment and Non-point Source Nitrogen and Phosphorus Discharge under Different Land uses Based on SWAT Model: A Case Study of Er hai Lake Small Watershed

    Science.gov (United States)

    Tong, Xiao Xia; Lai Cui, Yuan; Chen, Man Yu; Hu, Bo; Xu, Wen Sheng

    2018-05-01

    The Er yuan watershed of Er hai district is chosen as the research area, the law of runoff and sediment and non-point source nitrogen and phosphorus discharges under different land uses during 2001 to 2014 are simulated based on SWAT model. Results of simulation indicate that the order of total runoff yield of different land use type from high to low is grassland, paddy fields, dry land. Specifically, the order of surface runoff yield from high to low is paddy fields, dry land, grassland, the order of lateral runoff yield from high to low is paddy fields, dry land, grassland, the order of groundwater runoff yield from high to low is grassland, paddy fields, dry land. The orders of sediment and nitrogen and phosphorus yield per unit area of different land use type are the same, grassland> paddy fields> dry land. It can be seen, nitrogen and phosphorus discharges from paddy fields and dry land are the main sources of agricultural non-point pollution of the irrigated area. Therefore, reasonable field management measures which can decrease the discharge of nitrogen and phosphorus of paddy fields and dry land are the key to agricultural non-point source pollution prevention and control.

  6. Characteristics of a multidipole ion source

    International Nuclear Information System (INIS)

    Leung, K.N.; Collier, R.D.; Marshall, L.B.; Gallaher, T.N.; Ingham, W.H.; Kribel, R.E.; Taylor, G.R.

    1978-01-01

    The properties of a steady-state, dc discharge multidipole ion source have been investigated. The plasma density in the source depends on the magnet geometries, the discharge voltage, and the bias voltage on the first extraction grid. Different schemes to reduce the loss of ions to the chamber wall are described. Hydrogen ion species in the extracted beam are studied by a mass analyzer

  7. Modeling of electrical confined-capillary-discharge where the discharge zone is extended by an additional pipe

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, E. [Propulsion Physics Laboratory, Soreq NRC, Yavne 81800 (Israel)], E-mail: eyal_we@soreq.gov.il; Zoler, D.; Wald, S. [Propulsion Physics Laboratory, Soreq NRC, Yavne 81800 (Israel); Elias, E. [Department of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa 32000 (Israel)

    2009-03-02

    Plasma injectors are a source of pulsed, high momentum and temperature fluid. This fluid can serve as a very efficient reactive mixing and accelerating agent in several applications including chemical waste decomposition and hard materials coating. It can also serve as an efficient medium for synthesis of nano-particles and their deposition on various substrates. In those applications tuning the momentum and the thermodynamic properties of the plasma jet is of paramount importance as the quality of the interaction strongly depends on them. This Letter proposes a method and a model that will allow additional tuning to the thermodynamic properties of the plasma jet by adding an extension to the discharge zone. A steady state model of processes taking place in a realistic confined capillary discharge system is presented. A comparison between this system and the parameters characterizing a discharge in a 'conventional' ablative system is presented. The results obtained indicate that the non-discharge zone may provide an additional degree of freedom to optimize the system's performance. It enhances the control of the plasma parameters that allows optimal and predictable momentum control over the plasma jet. The theoretical predictions for the plasma parameters agree well with experimentally obtained data.

  8. Protection of neutral-beam accelerator electrodes from spark discharges

    International Nuclear Information System (INIS)

    Praeg, W.F.

    1977-01-01

    The high-voltage (HV) electrodes of neutral beam sources (NBS's) must be protected from occasional sparks to ground. Spark currents can be limited with special transformers and reactors which introduce time delays that are long enough to quench the spark or to disconnect the energy source. A saturated time delay transformer (STDT) connected in series with the HV power supply detects spark faults and limits the current supplied by the power supply and its capacitance to ground; it also initiates spark quenching. Nonsaturated, longitudinal reactors limit the discharge current supplied by the energy stored in the circuit capacitance of the NBS filament and arc power supplies long enough to discharge this capacitance into a resistor. The design principles of these protective circuits are presented

  9. Protection of neutral-beam-accelerator electrodes from spark discharges

    International Nuclear Information System (INIS)

    Praeg, W.F.

    1977-01-01

    The high-voltage (HV) electrodes of neutral beam sources (NBS's) must be protected from occasional sparks to ground. Spark currents can be limited with special transformers and reactors which introduce time delays that are long enough to quench the spark or to disconnect the energy source. A saturated time delay transformer (STDT) connected in series with the HV power supply detects spark faults and limits the current supplied by the power supply and its capacitance to ground; it also initiates spark quenching. Nonsaturated, longitudinal reactors limit the discharge current supplied by the energy stored in the circuit capacitance of the NBS filament and arc power supplies long enough to discharge this capacitance into a resistor. The design principles of these protective circuits are presented in this paper

  10. Protection of neutral-beam-accelerator electrodes from spark discharges

    International Nuclear Information System (INIS)

    Praeg, W.F.

    1978-01-01

    The high-voltage (HV) electrodes of neutral beam sources (NBS's) must be protected from occasional sparks to ground. Spark currents can be limited with special transformers and reactors which introduce time delays that are long enough to quench the spark or to disconnect the energy source. A saturated time delay transformer (STDT) connected in series with the HV power supply detects spark faults and limits the current supplied by the power supply and its capacitance to ground; it also initiates spark quenching. Nonsaturated, longitudinal reactors limit the discharge current supplied by the energy stored in the circuit capacitance of the NBS filament and arc power supplies long enough to discharge this capacitance into a resistor. The design principles of these protective circuits are presented in this paper

  11. Discharge source coupled to a deceleration unit for anion beam generation: Application to H{sub 2}{sup −} photodetachment

    Energy Technology Data Exchange (ETDEWEB)

    Rudnev, V.; Ureña, A. González [Unidad de Láseres y Haces Moleculares, Instituto Pluridisciplinar, Universidad Complutense, Juan XXIII-1, Madrid 28040 (Spain)

    2013-12-15

    A cathode discharge source coupled to a deceleration unit for anion beam generation is described. The discharge source, made of stainless steel or duralumin electrodes and Macor insulators, is attached to the exit nozzle valve plate at one end, and to an Einzel lens to the other end. Subsequently, a cylindrical retardation unit is attached to the Einzel lens to decelerate the ions in order to optimize the laser beam interaction time required for spectroscopic investigations. The compact device is able to produce beam intensities of the order of 2 × 10{sup 12} anions/cm{sup 2} s and 20 μrad of angular divergence with kinetic energies ranging from 30 to 120 eV. Using distinct gas mixtures for the supersonic expansion together with a linear time-of-flight spectrometer, anions of great relevance in molecular astrophysics like, for example, H{sub 2}{sup −}, C{sub 3}H{sup −}, C{sub 2}{sup −}, C{sub 2}H{sup −}, HCN{sub 2}{sup −}, CO{sub 2}{sup −}, CO{sub 2}H{sup −}, C{sub 4}{sup −}, C{sub 4}H{sup −}, C{sub 5}H{sub 4}{sup −}, C{sub 5}H{sub 6}{sup −}, C{sub 7}N{sup −}, and C{sub 10}N{sup −} were produced. Finally, in order to demonstrate the capability of the experimental technique the photodetachment cross-section of the metastable H{sub 2}{sup −}, predominantly in the (v = 0, J = 26) state, was measured following laser excitation at λ{sub exc}= 565 nm obtaining a value of σ{sub ph}= 0.04 Å. To the best of our knowledge, it is the first time that this anion cross-section has been measured.

  12. On-line measurement of microwave power in ECR ion source

    International Nuclear Information System (INIS)

    Zhou Changgeng; Kang Wu; Hu Yonghong; Li Yan; Lou Benchao; Zu Xiulan; Xiong Riheng; Chen Junguang; Li Xiaoyun

    2005-01-01

    It is a new technology to apply an ECR ion source to the neutron generator. Because of the structure limitation, working state of the ECR ion source could not be judged by the color of gas discharging in discharge chamber. Therefore, it was hard to estimate if the ECR ion source was working properly in the neutron generator. The method to resolve the problem was described in this paper. The microwave power was measured on-line by a directional coupler and a small microwave power meter. The ion beam current could be educed from the measured incidence microwave power, and discharge state in discharge chamber could be determined. (authors)

  13. Assessment of wastewater treatment facility compliance with decreasing ammonia discharge limits using a regression tree model.

    Science.gov (United States)

    Suchetana, Bihu; Rajagopalan, Balaji; Silverstein, JoAnn

    2017-11-15

    A regression tree-based diagnostic approach is developed to evaluate factors affecting US wastewater treatment plant compliance with ammonia discharge permit limits using Discharge Monthly Report (DMR) data from a sample of 106 municipal treatment plants for the period of 2004-2008. Predictor variables used to fit the regression tree are selected using random forests, and consist of the previous month's effluent ammonia, influent flow rates and plant capacity utilization. The tree models are first used to evaluate compliance with existing ammonia discharge standards at each facility and then applied assuming more stringent discharge limits, under consideration in many states. The model predicts that the ability to meet both current and future limits depends primarily on the previous month's treatment performance. With more stringent discharge limits predicted ammonia concentration relative to the discharge limit, increases. In-sample validation shows that the regression trees can provide a median classification accuracy of >70%. The regression tree model is validated using ammonia discharge data from an operating wastewater treatment plant and is able to accurately predict the observed ammonia discharge category approximately 80% of the time, indicating that the regression tree model can be applied to predict compliance for individual treatment plants providing practical guidance for utilities and regulators with an interest in controlling ammonia discharges. The proposed methodology is also used to demonstrate how to delineate reliable sources of demand and supply in a point source-to-point source nutrient credit trading scheme, as well as how planners and decision makers can set reasonable discharge limits in future. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. All solid state pulsed power system for water discharge

    OpenAIRE

    Sakugawa, Takashi; Yamaguchi, Takahiro; Yamamoto, Kunihiro; Kiyan, Tsuyoshi; Namihira, Takao; Katsuki, Sunao; Akiyama, Hidenori; サクガワ, タカシ; ヤマグチ, タカヒロ; ヤマモト, クニヒロ; キヤン, ツヨシ; ナミヒラ, タカオ; カツキ, スナオ; アキヤマ, ヒデノリ; 佐久川, 貴志

    2005-01-01

    Pulsed power has been used to produce non-thermal plasmas in gases that generate a high electric field at the tip of streamer discharges, where high energy electrons, free radicals, and ozone are produced. Recently, all solid state pulsed power generators, which are operated with high repetition rate, long lifetime and high reliability, have been developed for industrial applications, such as high repetition rate pulsed gas lasers, high energy density plasma (EUV sources) and water discharges...

  15. Investigation of primary cooling water chemistry following the partial meltdown of Pu-Be neutron source in Tehran Research Reactor Core (TRR)

    Energy Technology Data Exchange (ETDEWEB)

    Aghoyeh, Reza Gholizadeh [School of Research and Development of Nuclear Reactors and Accelerators, Nuclear Science and Technology Research Institute (NSTRI), Atomic Energy Organization of Iran (AEOI), P.O. Box: 14155-1339, Tehran (Iran, Islamic Republic of); Khalafi, Hossein, E-mail: hkhalafi@aeoi.org.i [School of Research and Development of Nuclear Reactors and Accelerators, Nuclear Science and Technology Research Institute (NSTRI), Atomic Energy Organization of Iran (AEOI), P.O. Box: 14155-1339, Tehran (Iran, Islamic Republic of)

    2011-03-15

    Research highlights: Effect of Pu-Be neutron source meltdown in core on reactor water chemistry. Water chemistry of primary cooling before, during and after of above incident was compared. Training importance. Management of nuclear incident and accident. - Abstract: Effect of Pu-Be neutron source meltdown in core on reactor water chemistry was main aim of this study. Leaving the neutron source in the core after reactor power exceeds a few hundred Watts was the main reason for its partial meltdown. Water chemistry of primary cooling before, during and after of above incident was compared. Activity of some radio-nuclides such as Ba-140, La-140, I-131, I-132, Te-132 and Xe-135 increased. Other radio-nuclides such as Nd-147, Xe-133, Sr-91, I-133 and I-135 are also detected which were not existed before this incident.

  16. Observations and Inferred Physical Characteristics of Compact Intracloud Discharges

    International Nuclear Information System (INIS)

    Argo, P.E.; Eack, K.B.; Holden, D.N.; Massey, R.S.; Shao, X.; Smith, D.A.; Wiens, K.C.

    1999-01-01

    Compact intracloud discharges (CIDS) represent a distinct class of electrical discharges that occur within intense regions of thunderstorms. They are singular discharges that produce brief (typically 3 ampersand micro;s in duration) broadband RF emissions that are 20 to 30 dB more powerful than radiation from all other recorded lightning processes in the HF and VHF radio spectrum. Far field electric field change recordings of CIDS consist of a single, large-amplitude bipolar pulse that begins to rise during the RF-producing phase of the CID and typically lasts for 20 ampersand micro;s. During the summer of 1998 we operated a 4-station array of electric field change meters in New Mexico to support FORTE satellite observations of transient RF and optical sources and to learn more about the phenomenology and physical characteristics of CIDS. Over 800 CIDS were detected and located during the campaign. The events were identified on the basis of their unique field change waveforms. CID source heights determined using the relative delays of ionospherically reflected source emissions were typically between 4 and 11 km above ground level. Events of both positive and negative polarity were observed with events' of initially- negative polarity (indicative of discharges occurring between underlying positive and overlying negative charge) occurring at slightly higher altitudes. Within CID field change waveforms the CID pulse was often followed within a few ms by one or more smaller-amplitude pulses. We associate these subsequent pulses with the initial activity of a ''normal'' intracloud flash, the inference being that some fraction of the time, a CID initiates an intracloud lightning flash

  17. H- source developments

    International Nuclear Information System (INIS)

    Allison, P.W.

    1978-01-01

    The design and operation of a Penning discharge, cold cathode, surface plasma H - ion source are described. A high current density, about 2 A/cm 2 , is extracted from the source by putting about 20 keV across the 2 to 2 1 / 2 mm gap

  18. The Role of Electronegative Impurities in Ozone Generation by High Pressure Discharges

    International Nuclear Information System (INIS)

    Skalny, J.

    2000-01-01

    The high pressure discharges (pulsed or D C corona, barrier, gliding and the others), have been studied both experimentally and theoretically as sources of low temperature plasma for pollution control technologies. The potential of electrical discharge methods has been demonstrated for the decomposition of many types of VOC. The air or oxygen are used as a feed gas in which pollutant is diluted. The ozone production in air or oxygen in such discharges is also discussed

  19. Feasibility of partial replacement of fishmeal with proteins from different sources in diets of Korean rockfish ( Sebastes schlegeli)

    Science.gov (United States)

    Yan, Quangen; Zhu, Xiaoming; Yang, Yunxia; Han, Dong; Xie, Shouqi

    2014-12-01

    An 8-week feeding experiment was conducted in an indoor recirculation seawater system to investigate the effects of partial replacement of dietary fishmeal with proteins from five sources on the growth performance and feed utilization of Sebastes schlegeli. Six isonitrogenous and isoenergetic diets were formulated using fishmeal (FM, the control) as sole protein source, or proteins from five sources including poultry by-product meal (PBM), meat and bone meal (MBM), soybean meal (SBM), cottonseed meal (CSM) and canola meal (CNM). Fifteen percent of the crude protein provided by fish meal was replaced, respectively. The results showed that the differences in specific growth rate (SGR) and survival rate (SR) among fish fed PBM, MBM, SBM, CSM and whole FM diets were not significant. However, SGR and SR of fish fed CNM diet was significantly lower than that of other treatments. Feeding rate, feed conversion, nutrient retention showed similar patterns to that of growth. Fish fed CSM and CNM showed significantly lower apparent digestibility coefficient (ADC) of dry matter and gross energy than those fed others while fish fed CNM showed lower ADC of crude protein than those fed others ( Preplacement with CNM reduced fish growth and feed utilization.

  20. Efficacy of a partial hospital programme for adults with eating disorders.

    Science.gov (United States)

    Brown, Tiffany A; Cusack, Anne; Anderson, Leslie K; Trim, Julie; Nakamura, Tiffany; Trunko, Mary Ellen; Kaye, Walter H

    2018-05-01

    Partial hospital programmes (PHPs) have demonstrated efficacy in the treatment of eating disorders (EDs); however, few programmes have examined long-term outcomes across diagnoses, including subtypes of anorexia nervosa (AN). The present study examined the effectiveness of PHP for adult patients (n = 243) with AN-restricting subtype (n = 79), AN binge/purge subtype (n = 46), and bulimia nervosa (n = 118). These patients tended to have long-standing courses of illness (43%, illness duration >7 years) and high levels of psychiatric comorbidity (92.2%). Patients completed questionnaires at admission, discharge, and follow-up, M (SD) = 11.50 months (5.29). Through follow-up, all diagnoses demonstrated significant improvements in weight, ED psychopathology, and comorbid symptoms, with some exceptions for the AN binge/purge group. In exploratory analyses, 49% of patients met criteria for full or partial remission at discharge and 37% at follow-up. Results provide support for the effectiveness of PHP in improving ED outcomes in a severe sample through longer-term follow-up. Copyright © 2018 John Wiley & Sons, Ltd and Eating Disorders Association.

  1. Plasma Discharge Process in a Pulsed Diaphragm Discharge System

    Science.gov (United States)

    Duan, Jianjin; Hu, Jue; Zhang, Chao; Wen, Yuanbin; Meng, Yuedong; Zhang, Chengxu

    2014-12-01

    As one of the most important steps in wastewater treatment, limited study on plasma discharge process is a key challenge in the development of plasma applications. In this study, we focus on the plasma discharge process of a pulsed diaphragm discharge system. According to the analysis, the pulsed diaphragm discharge proceeds in seven stages: (1) Joule heating and heat exchange stage; (2) nucleated site formation; (3) plasma generation (initiation of the breakdown stage); (4) avalanche growth and plasma expansion; (5) plasma contraction; (6) termination of the plasma discharge; and (7) heat exchange stage. From this analysis, a critical voltage criterion for breakdown is obtained. We anticipate this finding will provide guidance for a better application of plasma discharges, especially diaphragm plasma discharges.

  2. Discharge inventory of pharmaceuticals and personal care products in Beijing, China

    Directory of Open Access Journals (Sweden)

    Zhixia Zhang

    2016-09-01

    Full Text Available Pharmaceuticals and personal care products (PPCPs are emerging environmental contaminants, whose potential risk for the ecological environment has caused wide attention in recent years. In China, quite a large amount of PPCPs were annually emitted into the environment. Their existence in different matrix has been reported frequently, including river water, sediment and soil. However, the contribution from different sources was seldom reported and still unclear in China. Wastewater treatment plant (WWTP was usually considered to be the main source to the urban river, but livestock and aquaculture farms were also reported as significant pollution sources of PPCPs due to poor environmental management in China. This study summarized environmental discharges of different PPCPs from various sources and obtained the discharge data through different environment media in Beijing, the statistical source of PPCPs was analyzed in detail. The sources comprised WWTPs, excess sludge, hospital wastewater, municipal untreated wastewater, aquaculture wastewater and landfill leachate. This article helps understand the general situation and the potential risk of PPCPs in Beijing.

  3. An inverse optimal control problem in the electrical discharge ...

    Indian Academy of Sciences (India)

    Marin Gostimirovic

    2018-05-10

    May 10, 2018 ... Keywords. EDM process; discharge energy; heat source parameters; inverse problem; optimization. 1. Introduction .... ation, thermal modeling of the EDM process would become ..... simulation of die-sinking EDM. CIRP Ann.

  4. Novel design of high voltage pulse source for efficient dielectric barrier discharge generation by using silicon diodes for alternating current

    Science.gov (United States)

    Truong, Hoa Thi; Hayashi, Misaki; Uesugi, Yoshihiko; Tanaka, Yasunori; Ishijima, Tatsuo

    2017-06-01

    This work focuses on design, construction, and optimization of configuration of a novel high voltage pulse power source for large-scale dielectric barrier discharge (DBD) generation. The pulses were generated by using the high-speed switching characteristic of an inexpensive device called silicon diodes for alternating current and the self-terminated characteristic of DBD. The operation started to be powered by a primary DC low voltage power supply flexibly equipped with a commercial DC power supply, or a battery, or DC output of an independent photovoltaic system without transformer employment. This flexible connection to different types of primary power supply could provide a promising solution for the application of DBD, especially in the area without power grid connection. The simple modular structure, non-control requirement, transformer elimination, and a minimum number of levels in voltage conversion could lead to a reduction in size, weight, simple maintenance, low cost of installation, and high scalability of a DBD generator. The performance of this pulse source has been validated by a load of resistor. A good agreement between theoretically estimated and experimentally measured responses has been achieved. The pulse source has also been successfully applied for an efficient DBD plasma generation.

  5. Inverted end-Hall-type low-energy high-current gaseous ion source

    International Nuclear Information System (INIS)

    Oks, E. M.; Vizir, A. V.; Shandrikov, M. V.; Yushkov, G. Yu.; Grishin, D. M.; Anders, A.; Baldwin, D. A.

    2008-01-01

    A novel approach to low-energy, high-current, gaseous ion beam generation was explored and an ion source based on this technique has been developed. The source utilizes a dc high-current (up to 20 A) gaseous discharge with electron injection into the region of ion generation. Compared to the conventional end-Hall ion source, the locations of the discharge anode and cathode are inverted: the cathode is placed inside the source and the anode outside, and correspondingly, the discharge current is in the opposite direction. The discharge operates in a diverging axial magnetic field, similar to the end-Hall source. Electron generation and injection is accomplished by using an additional arc discharge with a ''cold'' (filamentless) hollow cathode. Low plasma contamination is achieved by using a low discharge voltage (avoidance of sputtering), as well as by a special geometric configuration of the emitter discharge electrodes, thereby filtering (removing) the erosion products stemming from the emitter cathode. The device produces a dc ion flow with energy below 20 eV and current up to 2.5 A onto a collector of 500 cm 2 at 25 cm from the source edge, at a pressure ≥0.02 Pa and gas flow rate ≥14 SCCM. The ion energy spread is 2 to 3 eV (rms). The source is characterized by high reliability, low maintenance, and long lifetime. The beam contains less than 0.1% of metallic ions. The specific electric energy consumption is 400 eV per ion registered at the collector. The source operates with noble gases, nitrogen, oxygen, and hydrocarbons. Utilizing biasing, it can be used for plasma sputtering, etching, and other ion technologies

  6. Double discharges in unipolar-pulsed dielectric barrier discharge xenon excimer lamps

    International Nuclear Information System (INIS)

    Liu Shuhai; Neiger, Manfred

    2003-01-01

    Excitation of dielectric barrier discharge xenon excimer lamps by unipolar short square pulses is studied in this paper. Two discharges with different polarity are excited by each voltage pulse (double discharge phenomenon). The primary discharge occurs at the top or at the rising flank of the applied unipolar square pulse, which is directly energized by the external circuit. The secondary discharge with the reversed polarity occurs at the falling flank or shortly after the falling flank end (zero external voltage) depending on the pulse width, which is energized by the energy stored by memory charges deposited by the primary discharge. Fast-speed ICCD imaging shows the primary discharge has a conic discharge appearance with a channel broadening on the anode side. This channel broadening increases with increasing the pulse top level. Only the anode-side surface discharge is observed in the primary discharge. The surface discharge on the cathode side which is present in bipolar sine voltage excitation is not observed. On the contrary, the secondary discharge has only the cathode-side surface discharge. The surface discharge on the anode side is not observed. The secondary discharge is much more diffuse than the primary discharge. Time-resolved emission measurement of double discharges show the secondary discharge emits more VUV xenon excimer radiation but less infrared (IR) xenon atomic emission than the primary discharge. It was found that the IR xenon atomic emission from the secondary discharge can be reduced by shortening the pulse width. The energy efficiency of unipolar-pulsed xenon excimer lamps (the overall energy efficiency of double discharges) is much higher than that obtained under bipolar sine wave excitation. The output VUV spectrum under unipolar pulse excitation is found to be identical to that under sine wave excitation and independent of injected electric power

  7. Feasibility study on partial insulation winding technique for the development of self-protective MgB2 magnet

    Science.gov (United States)

    Kim, Y. G.; Kim, J. C.; Kim, J. M.; Yoo, B. H.; Hwang, D. Y.; Lee, H. G.

    2018-06-01

    This study investigates the feasibility of using the partial insulation winding technique for the development of a self-protective MgB2 MRI magnet with a fast charge-discharge rate. Charge-discharge and quench tests for a prototype PI MgB2 magnet confirmed that the magnet was successfully operated at full-field performance and exhibited self-protecting behavior in the event of a quench. Nonetheless, the required time to charge the 0.5-T/300-mm PI MgB2 magnet was almost five days, implying that the charge-discharge delay of the PI MgB2 magnet still needs to be ameliorated further to develop a real-scale MgB2 MRI magnet with a fast charge-discharge rate.

  8. Instream biological assessment of NPDES point source discharges at the Savannah River Site, 1997-1998

    International Nuclear Information System (INIS)

    Specht, W.L.

    2000-01-01

    The Savannah River Site currently has 33 permitted NPDES outfalls that have been permitted by the South Carolina Department of Health an Environmental Control to discharge to SRS streams and the Savannah River. In order to determine the cumulative impacts of these discharges to the receiving streams, a study plan was developed to perform in-stream assessments of the fish assemblages, macroinvertebrate assemblages, and habitats of the receiving streams

  9. Instream biological assessment of NPDES point source discharges at the Savannah River Site, 1997-1998

    Energy Technology Data Exchange (ETDEWEB)

    Specht, W.L.

    2000-02-28

    The Savannah River Site currently has 33 permitted NPDES outfalls that have been permitted by the South Carolina Department of Health an Environmental Control to discharge to SRS streams and the Savannah River. In order to determine the cumulative impacts of these discharges to the receiving streams, a study plan was developed to perform in-stream assessments of the fish assemblages, macroinvertebrate assemblages, and habitats of the receiving streams.

  10. Heat sources for glacial ice melt in a West Greenland tidewater outlet glacier fjord: The role of subglacial freshwater discharge

    DEFF Research Database (Denmark)

    Bendtsen, Jørgen; Mortensen, John; Lennert, Kunuk

    2015-01-01

    The melting of tidewater outlet glaciers from the Greenland Ice Sheet contributes significantly to global sea level rise. Accelerated mass loss is related to melt-processes in front of calving glaciers, yet the role of ocean heat transports is poorly understood. Here we present the first direct...... of the area near the glacier showed that ice melt was mainly due to ocean heat transport and that direct plume-associated melt was only important in periods with high meltwater discharge rates of ~100 m3 s−1. Ocean mixing outside of the plume area was thus the primary heat source for melting glacier ice....

  11. Approach to modeling of the fast energy discharge in cryogenic systems in the form of an electric arc

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    Superconducting magnets are supplied with a few kA of electric current and can store a large amount of energy. Therefore, cryogenic systems which are comprised of such magnets are subject to the risk of fast energy discharge from the magnets themselves in the form of an electric arc. The arcing can be a result of failure in the insulation of an electric circuit or in the connection between the magnet and its current lead. During the discharge, energy can be partially dissipated into the cryogen and partially into the cryogenic system metallic structure. The part of the energy that is transferred to the metallic structure will strongly heat up the metal surface, which can lead to material burning. In this case, the cryogen will flow through the perforation to the insulation vacuum space, which can trigger a rapid increase in pressure in the vacuum enclosure. However, the discharged energy that has been stored in the cryogen also causes a rapid increase in cryogenic pressure. Hence, the proper estimation of the...

  12. Characterization of a dielectric barrier discharge in controlled atmosphere

    Science.gov (United States)

    Kogelheide, Friederike; Offerhaus, Björn; Bibinov, Nikita; Bracht, Vera; Smith, Ryan; Lackmann, Jan-Wilm; Awakowicz, Peter; Stapelmann, Katharina; Bimap Team; Aept Team

    2016-09-01

    Non-thermal atmospheric-pressure plasmas are advantageous for various biomedical applications as they make a contact- and painless therapy possible. Due to the potential medical relevance of such plasma sources further understanding of the chemical and physical impact on biological tissue regarding the efficacy and health-promoting effect is necessary. The knowledge of properties and effects offers the possibility to configure plasmas free of risk for humans. Therefore, tailoring the discharge chemistry in regard to resulting oxidative and nitrosative effects on biological tissue by adjusting different parameters is of growing interest. In order to ensure stable conditions for the characterization of the discharge, the used dielectric barrier discharge was mounted in a vessel. Absolutely calibrated optical emission spectroscopy was carried out to analyze the electron density and the reduced electric field. The rather oxygen-based discharge was tuned towards a more nitrogen-based discharge by adjusting several parameters as reactive nitrogen species are known to promote wound healing. Furthermore, the impact of an ozone-free discharge has to be studied. This work was funded by the German Research Foundation (DFG) with the packet grant PAK 816 `Plasma Cell Interaction in Dermatology'.

  13. Localization Accuracy of Distributed Inverse Solutions for Electric and Magnetic Source Imaging of Interictal Epileptic Discharges in Patients with Focal Epilepsy.

    Science.gov (United States)

    Heers, Marcel; Chowdhury, Rasheda A; Hedrich, Tanguy; Dubeau, François; Hall, Jeffery A; Lina, Jean-Marc; Grova, Christophe; Kobayashi, Eliane

    2016-01-01

    Distributed inverse solutions aim to realistically reconstruct the origin of interictal epileptic discharges (IEDs) from noninvasively recorded electroencephalography (EEG) and magnetoencephalography (MEG) signals. Our aim was to compare the performance of different distributed inverse solutions in localizing IEDs: coherent maximum entropy on the mean (cMEM), hierarchical Bayesian implementations of independent identically distributed sources (IID, minimum norm prior) and spatially coherent sources (COH, spatial smoothness prior). Source maxima (i.e., the vertex with the maximum source amplitude) of IEDs in 14 EEG and 19 MEG studies from 15 patients with focal epilepsy were analyzed. We visually compared their concordance with intracranial EEG (iEEG) based on 17 cortical regions of interest and their spatial dispersion around source maxima. Magnetic source imaging (MSI) maxima from cMEM were most often confirmed by iEEG (cMEM: 14/19, COH: 9/19, IID: 8/19 studies). COH electric source imaging (ESI) maxima co-localized best with iEEG (cMEM: 8/14, COH: 11/14, IID: 10/14 studies). In addition, cMEM was less spatially spread than COH and IID for ESI and MSI (p < 0.001 Bonferroni-corrected post hoc t test). Highest positive predictive values for cortical regions with IEDs in iEEG could be obtained with cMEM for MSI and with COH for ESI. Additional realistic EEG/MEG simulations confirmed our findings. Accurate spatially extended sources, as found in cMEM (ESI and MSI) and COH (ESI) are desirable for source imaging of IEDs because this might influence surgical decision. Our simulations suggest that COH and IID overestimate the spatial extent of the generators compared to cMEM.

  14. Effects of oxygen partial pressure on Li-air battery performance

    Science.gov (United States)

    Kwon, Hyuk Jae; Lee, Heung Chan; Ko, Jeongsik; Jung, In Sun; Lee, Hyun Chul; Lee, Hyunpyo; Kim, Mokwon; Lee, Dong Joon; Kim, Hyunjin; Kim, Tae Young; Im, Dongmin

    2017-10-01

    For application in electric vehicles (EVs), the Li-air battery system needs an air intake system to supply dry oxygen at controlled concentration and feeding rate as the cathode active material. To facilitate the design of such air intake systems, we have investigated the effects of oxygen partial pressure (≤1 atm) on the performance of the Li-air cell, which has not been systematically examined. The amounts of consumed O2 and evolved CO2 from the Li-air cell are measured with a custom in situ differential electrochemical gas chromatography-mass spectrometry (DEGC-MS). The amounts of consumed O2 suggest that the oxygen partial pressure does not affect the reaction mechanism during discharge, and the two-electron reaction occurs under all test conditions. On the other hand, the charging behavior varies by the oxygen partial pressure. The highest O2 evolution ratio is attained under 70% O2, along with the lowest CO2 evolution. The cell cycle life also peaks at 70% O2 condition. Overall, an oxygen partial pressure of about 0.5-0.7 atm maximizes the Li-air cell capacity and stability at 1 atm condition. The findings here indicate that the appropriate oxygen partial pressure can be a key factor when developing practical Li-air battery systems.

  15. Behavior of water jet horizontally discharged from a small circular hole set on a circular pipe-surface into air

    International Nuclear Information System (INIS)

    Tsuyuki, Koji; Igarashi, Saburo; Sudo, Seiichi; Yamabe, Masahiro; Kikuchi, Akira; Oba, Risaburo

    2001-01-01

    In order to clarify the behavior of the water jet horizontally discharged from a small circular hole set on a circular pipe surface into air, in this paper, for the first step, we systematically observed the jet aspects, the efflux angle, the discharge coefficient and so on, when the hole diameter d is much smaller than the pipe diameter D. Since the upstream kinetic energy from the hole is somewhat higher than the downstream counterpart, the upstream partial jet with higher efflux angle crashes into the downstream partial jet and drives out the latter into up- and down-side, resulting in a marked pair of vortices, so that resulting in a three-dimensional spiral flow accompanying with marked surface waves. (author)

  16. Mitigation of pressure fluctuations in the discharge cone of hydraulic turbines using flow-feedback

    International Nuclear Information System (INIS)

    Tanasa, C; Susan-Resiga, R; Bosioc, A; Muntean, S

    2010-01-01

    Our previous experimental and numerical investigations of decelerated swirling flows in conical diffusers have demonstrated that water jet injection along the symmetry axis mitigates the pressure fluctuations associated with the precessing vortex rope. However, for swirling flows similar to Francis turbines operated at partial discharge, the jet becomes effective when the jet discharge is larger than 10% from the turbine discharge, leading to large volumetric losses when the jet is supplied from upstream the runner. As a result, we introduce in this paper a new approach for supplying the jet by using a fraction of the discharge collected downstream the conical diffuser. We present the technical implementation of this flow-feedback approach, and we investigated experimentally its capability in mitigating the pressure fluctuations generated by the precessing vortex rope. The main advantage of this flow-feedback approach is that is does not require additional energy to supply the jet and it does not decrease the turbine efficiency.

  17. Atomization of thorium in a hollow-cathode type discharge

    International Nuclear Information System (INIS)

    Pianarosa, P.; Demers, Y.; Gagne, J.M.

    1984-01-01

    The atomization of thorium metal in a hollow-cathode electrical discharge has been investigated. Laser absorption spectroscopy with the laser tuned on the 5760.55 A (0-17355 1 cm -1 ) transition of Th I was used to evaluate the density of atoms in the 3 F 2 ground state. The results obtained (densities up to 10 13 atoms cm -3 ) show that our discharge tube is a suitable source of thorium metal atoms for laser assisted spectroscopic analysis of this element. (author)

  18. A study of capillary discharge lamps in Ar-Hg and Xe-Hg mixtures

    International Nuclear Information System (INIS)

    Denisova, N; Gavare, Z; Revalde, G; Skudra, Ja; Veilande, R

    2011-01-01

    Low-pressure capillary discharge lamps in Ar-Hg and Xe-Hg mixtures are studied. The discharge size is 0.5 mm (500 μm) in radius. According to the literature, such types of plasma sources are classified as microplasmas. The studies include spectrally resolved optical measurements, tomographic reconstructions and numerical simulations using the collisional-radiative model for an Ar-Hg plasma. We discuss the problems of theoretical modelling and experimental diagnostics of microplasma sources. It is shown that the conventional collisional-radiative model, based on the assumption that transportation of atoms in the highly excited states can be neglected, has limitations in modelling a capillary discharge in an Ar-Hg mixture. It is found that diffusion of highly excited mercury atoms to the wall influences the emission properties of the capillary discharge. We have concluded that applications of the emission tomography method to microplasmas require a special analysis in each particular case.

  19. Preliminary investigation of processes that affect source term identification

    International Nuclear Information System (INIS)

    Wickliff, D.S.; Solomon, D.K.; Farrow, N.D.

    1991-09-01

    Solid Waste Storage Area (SWSA) 5 is known to be a significant source of contaminants, especially tritium ( 3 H), to the White Oak Creek (WOC) watershed. For example, Solomon et al. (1991) estimated the total 3 H discharge in Melton Branch (most of which originates in SWSA 5) for the 1988 water year to be 1210 Ci. A critical issue for making decisions concerning remedial actions at SWSA 5 is knowing whether the annual contaminant discharge is increasing or decreasing. Because (1) the magnitude of the annual contaminant discharge is highly correlated to the amount of annual precipitation (Solomon et al., 1991) and (2) a significant lag may exist between the time of peak contaminant release from primary sources (i.e., waste trenches) and the time of peak discharge into streams, short-term stream monitoring by itself is not sufficient for predicting future contaminant discharges. In this study we use 3 H to examine the link between contaminant release from primary waste sources and contaminant discharge into streams. By understanding and quantifying subsurface transport processes, realistic predictions of future contaminant discharge, along with an evaluation of the effectiveness of remedial action alternatives, will be possible. The objectives of this study are (1) to characterize the subsurface movement of contaminants (primarily 3 H) with an emphasis on the effects of matrix diffusion; (2) to determine the relative strength of primary vs secondary sources; and (3) to establish a methodology capable of determining whether the 3 H discharge from SWSA 5 to streams is increasing or decreasing

  20. Double chamber ion source

    International Nuclear Information System (INIS)

    Uman, M.F.; Winnard, J.R.; Winters, H.F.

    1978-01-01

    The ion source is comprised of two discharge chambers one of which is provided with a filament and an aperture leading into the other chamber which in turn has an extraction orifice. A low voltage arc discharge is operated in an inert gas atmosphere in the filament chamber while an arc of higher voltage is operated in the second ionization chamber which contains a vapor which will give the desired dopant ion species. The entire source is immersed in an axial magnetic field parallel to a line connecting the filament, the aperture between the two chambers and the extraction orifice. (author)

  1. Nested-scale discharge and groundwater level monitoring to improve predictions of flow route discharges and nitrate loads

    Science.gov (United States)

    van der Velde, Y.; Rozemeijer, J. C.; de Rooij, G. H.; van Geer, F. C.; Torfs, P. J. J. F.; de Louw, P. G. B.

    2010-10-01

    Identifying effective measures to reduce nutrient loads of headwaters in lowland catchments requires a thorough understanding of flow routes of water and nutrients. In this paper we assess the value of nested-scale discharge and groundwater level measurements for predictions of catchment-scale discharge and nitrate loads. In order to relate field-site measurements to the catchment-scale an upscaling approach is introduced that assumes that scale differences in flow route fluxes originate from differences in the relationship between groundwater storage and the spatial structure of the groundwater table. This relationship is characterized by the Groundwater Depth Distribution (GDD) curve that relates spatial variation in groundwater depths to the average groundwater depth. The GDD-curve was measured for a single field site (0.009 km2) and simple process descriptions were applied to relate the groundwater levels to flow route discharges. This parsimonious model could accurately describe observed storage, tube drain discharge, overland flow and groundwater flow simultaneously with Nash-Sutcliff coefficients exceeding 0.8. A probabilistic Monte Carlo approach was applied to upscale field-site measurements to catchment scales by inferring scale-specific GDD-curves from hydrographs of two nested catchments (0.4 and 6.5 km2). The estimated contribution of tube drain effluent (a dominant source for nitrates) decreased with increasing scale from 76-79% at the field-site to 34-61% and 25-50% for both catchment scales. These results were validated by demonstrating that a model conditioned on nested-scale measurements simulates better nitrate loads and better predictions of extreme discharges during validation periods compared to a model that was conditioned on catchment discharge only.

  2. The Influence of the Presence of Multiple Voids on the Discharge Patterns in Solid Epoxy Insulation

    DEFF Research Database (Denmark)

    Holbøll, Joachim T.; Henriksen, Mogens; Larsen, Esben

    1996-01-01

    In this paper, partial discharge test results from initial long term testing on samples which contain more voids, when exposed to a high electric stress will be presented. The influence on the discharge patterns, phase- and height-analyses, of such parameter as the number of voids and the void...... diameters will be given. A first evaluation/opinion of the impact this could have on the estimation of the insulation condition of electrical equipment, based on the identification of PD-patterns, will also be given....

  3. Hydrologic and water quality characteristics of a partially-flooded, abandoned underground coal mine

    International Nuclear Information System (INIS)

    Aljoe, W.W.

    1994-01-01

    The hydrologic and water quality characteristics of a partially flooded, abandoned underground coal mine near Latrobe, PA, were studied to support the development of techniques for in situ abatement of its acidic discharge. A quantitative understanding of the conditions affecting discharge flow was considered to be very important in this regard. Statistical analysis of hydrologic data collected at the site shows that the flow rate of the main discharge (a borehole that penetrates the mine workings just behind a set of portal seals) is a linear function of the height of the mine pool above the borehole outlet. Seepage through or around the portal seals is collected by a set of french drains whose discharge rate is largely independent of the mine pool elevation. This seepage was enhanced after a breakthrough that occurred during a period of unusually high pool levels. The mine pool recharge rate during winter is about 2.5 times greater than that of any other season; recharge rates during spring, summer, and fall are approximately equal. Mine pool and discharge water quality information, along with bromide tracer tests, suggest that the original main entries discharge primarily to the french drains, while the borehole carries the discharge from an unmonitored set of entries northwest of the mains. The water quality of the east french drain discharge may have been improved substantially after seepage through the alkaline materials used to construct the portal seals

  4. Sewage discharges and nutrient levels in Marimba River, Zimbabwe ...

    African Journals Online (AJOL)

    Sewage discharges and nutrient levels in Marimba River, Zimbabwe. ... Population distribution, land-use, industrial activity, urban agricultural ... River, one of the major inflow rivers into the Lake Chivero, Harare city\\'s main water supply source.

  5. Development status of electron cyclotron resonance ion sources (ECRIS). Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Zakhary, S G [Ion Sources and Accelerators Department, Nuclear Research Center, Atomic Energy Authority, Cairo, (Egypt)

    1996-03-01

    The present review provides a very brief introduction of the historical development of this recent trend type of ion sources. There are two main types of this source which use the microwave power (2.45 up to 20 GHz). ECR ion sources that can generate substantial currents of very high charge state ions ( for example ions of U with charge state +39, with intensities of a few hundred nano amperes for injection directly into cyclotrons or synchrotrons), and the microwave sources that can generate currents (100-500 mA) for ion implanters and accelerator injectors. In this work, the theory of the microwave discharge and influence of resonance on increasing the power density consumed by the discharge are studied. The power density consumed by the discharge is found to increase with increase of number of electrons in the discharge, and decreases with increase of discharge pressure. The description of the main components and factors affecting the design of the source are declared. Also the factors enhancing source performance such as: plasma cooling by the addition of light ions which absorb energy from the heavy ions thereby increasing the lifetime of the heavy ions, and increasing the extent of highly charged ions. Injection of electrons into the discharge increases the extracted ion current, and the decrease of the magnetic field in the extraction region decreases the beam emittance. 12 figs.

  6. Potential profile near singularity point in kinetic Tonks-Langmuir discharges as a function of the ion sources temperature

    Science.gov (United States)

    Kos, L.; Tskhakaya, D. D.; Jelić, N.

    2011-05-01

    A plasma-sheath transition analysis requires a reliable mathematical expression for the plasma potential profile Φ(x) near the sheath edge xs in the limit ɛ ≡λD/ℓ =0 (where λD is the Debye length and ℓ is a proper characteristic length of the discharge). Such expressions have been explicitly calculated for the fluid model and the singular (cold ion source) kinetic model, where exact analytic solutions for plasma equation (ɛ =0) are known, but not for the regular (warm ion source) kinetic model, where no analytic solution of the plasma equation has ever been obtained. For the latter case, Riemann [J. Phys. D: Appl. Phys. 24, 493 (1991)] only predicted a general formula assuming relatively high ion-source temperatures, i.e., much higher than the plasma-sheath potential drop. Riemann's formula, however, according to him, never was confirmed in explicit solutions of particular models (e.g., that of Bissell and Johnson [Phys. Fluids 30, 779 (1987)] and Scheuer and Emmert [Phys. Fluids 31, 3645 (1988)]) since "the accuracy of the classical solutions is not sufficient to analyze the sheath vicinity" [Riemann, in Proceedings of the 62nd Annual Gaseous Electronic Conference, APS Meeting Abstracts, Vol. 54 (APS, 2009)]. Therefore, for many years, there has been a need for explicit calculation that might confirm the Riemann's general formula regarding the potential profile at the sheath edge in the cases of regular very warm ion sources. Fortunately, now we are able to achieve a very high accuracy of results [see, e.g., Kos et al., Phys. Plasmas 16, 093503 (2009)]. We perform this task by using both the analytic and the numerical method with explicit Maxwellian and "water-bag" ion source velocity distributions. We find the potential profile near the plasma-sheath edge in the whole range of ion source temperatures of general interest to plasma physics, from zero to "practical infinity." While within limits of "very low" and "relatively high" ion source temperatures

  7. Sources for charged particles; Les sources de particules chargees

    Energy Technology Data Exchange (ETDEWEB)

    Arianer, J.

    1997-09-01

    This document is a basic course on charged particle sources for post-graduate students and thematic schools on large facilities and accelerator physics. A simple but precise description of the creation and the emission of charged particles is presented. This course relies on every year upgraded reference documents. Following relevant topics are considered: electronic emission processes, technological and practical considerations on electron guns, positron sources, production of neutral atoms, ionization, plasma and discharge, different types of positive and negative ion sources, polarized particle sources, materials for the construction of ion sources, low energy beam production and transport. (N.T.).

  8. Case Study: Effects of a Partial-Debris Dam on Riverbank Erosion in the Parlung Tsangpo River, China

    Directory of Open Access Journals (Sweden)

    Clarence Edward Choi

    2018-02-01

    Full Text Available This paper examines two successive debris flows that deposited a total of 1.4 million m3 of sediment into the Parlung Tsangpo River in China in 2010. As a result of these deposits, a partial-debris dam was formed in the river. This dam rerouted the discharge in the river along one of the riverbanks, which supported a highway. The rerouted discharge eroded the riverbank and the highway eventually collapsed. To enhance our understanding of the threat posed by partial-debris dams, a field investigation was carried out to measure the discharge in the river and to collect soil samples of the collapsed riverbank. Findings from the field investigation were then used to back-analyze fluvial erosion along the riverbank using a combined erosion framework proposed in this study. This combined framework adopts a dam-breach erosion model which can capture the progressive nature of fluvial erosion by considering the particle size distribution of the soil being eroded. The results from the back-analysis were then evaluated against unique high-resolution images obtained from satellites. This case study not only highlights the consequences of the formation of partial-debris dams on nearby infrastructure, but it also proposes the use of a combined erosion framework to provide a first-order assessment of riverbank stability. Unique high-resolution satellite images are used to assess the proposed erosion framework and key challenges in assessing erosion are discussed.

  9. Discharge data from 50 selected rivers for GCM validation

    International Nuclear Information System (INIS)

    Duemenil, L.; Isele, K.; Liebscher, H.J.; Schroeder, U.; Schumacher, M.; Wilke, K.

    1993-01-01

    This Technical Report refers to a joint project between GRDC Koblenz and MPI Hamburg. The Global Runoff Data Centre operates under the auspieces of WMO at the Federal Institute of Hydrology (Bundesanstalt fuer Gewaesserkunde) in Koblenz. River discharge data of the 50 largest rivers provide an independent data source for the validation of the hydrological cycle in general circulation models. This type of data is particularly valuable, because in some cases the available time series are exceptionally long. The data are presented as time series of annual average discharge (averaged over the period for which data is available, see below for caveats) and as annual cycles of monthly mean discharge averaged over the length of the time series available. (orig./KW)

  10. On-line measurement of the microwave power in ECR ion source

    International Nuclear Information System (INIS)

    Zhou Changgeng; Kang Wu; Hu Yonghong; Li Yan; Lou Benchao; Zu Xiulan; Xiong Riheng; Chen Junguang

    2005-01-01

    It is a new technology that ECR ion source is applied in the neutron generator. Because of effect of the structure, working state of ECR ion source could not be judged by the color of gas discharging in discharging chamber as doing in high frequency ion source. Therefore, state adjusting of ECR ion source was difficult in running of the neutron generator. The method to resolve the question is described in this paper. The micro-wave power was measured in case of running by using the method of directional coupler adding small microwave power meter. Because both were in the direct proportion, the ion beam current could be educed from microwave incidence power measured, and discharge state in discharge chamber could be judged. Finally, the neutron generator might be operated in best running state. (authors)

  11. Charged particle emission effects on the characteristics of glow discharges with oscillating electrons

    CERN Document Server

    Nikulin, S P

    2001-01-01

    One discusses the effect of selection of charged particles on conditions to maintain and the characteristics of a glow discharge with oscillating electrons. It is shown that there is a pressure dependent optimal level of ion selection when the energy efficiency of ion source reaches its maximum value. It is determined that departure of fast ionizing electrons affects negatively the discharge maintenance wile emission of slow plasma electrons may promote maintenance of a discharge high current shape. It is shown that high efficient electron emission without violation of a discharge stability may take place in a magnetic field due to different nature of spatial distributions of fast and slow particles in discharges with electron oscillation

  12. PS proton source

    CERN Multimedia

    1959-01-01

    The first proton source used at CERN's Proton Synchrotron (PS) which started operation in 1959. This is CERN's oldest accelerator still functioning today (2018). It is part of the accelerator chain that supplies proton beams to the Large Hadron Collider. The source is a Thonemann type. In order to extract and accelerate the protons at high energy, a high frequency electrical field is used (140Mhz). The field is transmitted by a coil around a discharge tube in order to maintain the gas hydrogen in an ionised state. An electrical field pulse, in the order of 15kV, is then applied via an impulse transformer between anode and cathode of the discharge tube. The electrons and protons of the plasma formed in the ionised gas in the tube, are then separated. Currents in the order of 200mA during 100 microseconds have benn obtained with this type of source.

  13. Nipple Discharge

    Science.gov (United States)

    ... any unexpected nipple discharge evaluated by a doctor. Nipple discharge in men under any circumstances could be a problem and needs further evaluation. One or both breasts may produce a nipple discharge, either spontaneously or when you squeeze your ...

  14. Lung surgery - discharge

    Science.gov (United States)

    ... Lung biopsy - discharge; Thoracoscopy - discharge; Video-assisted thoracoscopic surgery - discharge; VATS - discharge ... milk) for 2 weeks after video-assisted thoracoscopic surgery and 6 to 8 weeks after open surgery. ...

  15. Ostrich eggshell as calcium source for the synthesis of hydroxyapatite and hydroxyapatite partially substituted with zinc

    International Nuclear Information System (INIS)

    Ferreira, J.R.M.; Louro, L.H.L.; Costa, A.M.; Silva, M.H. Prado da; Campos, J.B. de

    2016-01-01

    In the present study, hydroxyapatite and Zn-substituted hydroxyapatite powders were synthesized using ostrich eggshell as a calcium source. The samples were analyzed by scanning electron microscopy with field emission gun, and X-ray diffraction (XRD) to identify the present phases, and X-ray fluorescence spectroscopy for quantitative chemical analysis of the synthesized and heat treated powders. The Fourier transform infrared spectroscopy technique was used before and after heat treatments at 700, 900 and 1100 °C in order to identify the functional groups present, as an additional technique to the XRD analysis. The results presented in this study represent a promising method for synthesis of hydroxyapatite and hydroxyapatite partially substituted with zinc, since the results showed no undesirable phases or impurities in the produced powders. It was observed that Zn-substituted hydroxyapatite showed higher thermal stability, when compared to pure hydroxyapatite. (author)

  16. Ostrich eggshell as calcium source for the synthesis of hydroxyapatite and hydroxyapatite partially substituted with zinc

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, J.R.M.; Louro, L.H.L.; Costa, A.M.; Silva, M.H. Prado da [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Campos, J.B. de, E-mail: josericardo@r-crio.com, E-mail: louro@ime.eb.br, E-mail: andrea@r-crio.com, E-mail: brantjose@gmail.com, E-mail: marceloprado@ime.eb.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2016-10-15

    In the present study, hydroxyapatite and Zn-substituted hydroxyapatite powders were synthesized using ostrich eggshell as a calcium source. The samples were analyzed by scanning electron microscopy with field emission gun, and X-ray diffraction (XRD) to identify the present phases, and X-ray fluorescence spectroscopy for quantitative chemical analysis of the synthesized and heat treated powders. The Fourier transform infrared spectroscopy technique was used before and after heat treatments at 700, 900 and 1100 °C in order to identify the functional groups present, as an additional technique to the XRD analysis. The results presented in this study represent a promising method for synthesis of hydroxyapatite and hydroxyapatite partially substituted with zinc, since the results showed no undesirable phases or impurities in the produced powders. It was observed that Zn-substituted hydroxyapatite showed higher thermal stability, when compared to pure hydroxyapatite. (author)

  17. Modulating Function-Based Method for Parameter and Source Estimation of Partial Differential Equations

    KAUST Repository

    Asiri, Sharefa M.

    2017-10-08

    Partial Differential Equations (PDEs) are commonly used to model complex systems that arise for example in biology, engineering, chemistry, and elsewhere. The parameters (or coefficients) and the source of PDE models are often unknown and are estimated from available measurements. Despite its importance, solving the estimation problem is mathematically and numerically challenging and especially when the measurements are corrupted by noise, which is often the case. Various methods have been proposed to solve estimation problems in PDEs which can be classified into optimization methods and recursive methods. The optimization methods are usually heavy computationally, especially when the number of unknowns is large. In addition, they are sensitive to the initial guess and stop condition, and they suffer from the lack of robustness to noise. Recursive methods, such as observer-based approaches, are limited by their dependence on some structural properties such as observability and identifiability which might be lost when approximating the PDE numerically. Moreover, most of these methods provide asymptotic estimates which might not be useful for control applications for example. An alternative non-asymptotic approach with less computational burden has been proposed in engineering fields based on the so-called modulating functions. In this dissertation, we propose to mathematically and numerically analyze the modulating functions based approaches. We also propose to extend these approaches to different situations. The contributions of this thesis are as follows. (i) Provide a mathematical analysis of the modulating function-based method (MFBM) which includes: its well-posedness, statistical properties, and estimation errors. (ii) Provide a numerical analysis of the MFBM through some estimation problems, and study the sensitivity of the method to the modulating functions\\' parameters. (iii) Propose an effective algorithm for selecting the method\\'s design parameters

  18. Electrical discharge phenomena application for solid fossil fuels in-situ conversion

    International Nuclear Information System (INIS)

    Bukharkin, A A; Lopatin, V V; Martemyanov, S M; Koryashov, I A

    2014-01-01

    The application of high voltage to oil shale initiates partial discharges (PDs) with the following treeing like in insulating dielectrics. Critical PDs and treeing with a high propagation rate occur under the low electrical intensity ∼10 2 V/cm due to oil shale's high porosity, heterogeneity and anisotropy. The completed discharge occurs as a result of these phenomena. Carbonization is initiated around a plasma channel at the treeing stage and extended during electromagnetic action time. Carbonized rock electrical resistance decreases by 8÷10 degrees to 10 ohm·cm, and shale and coal could be heated by Joule heat in carbonized volume and discharge plasma. A high-current supply is necessary for this heating stage. Also, a high- voltage supply with steep-grade characteristics can be used for PDs and treeing initiating and heating the carbonized rock with low resistance. Thus, these phenomena allow in-situ processing in order to produce a flammable gas and synthetic oil from inferior solid fossil fuels by pyrolytic conversion. Computations show that the ratio between energy derived from gas flaming and energy for shale conversion is more than fifty. Therefore, oil shale conversion with the help of electrical discharge phenomena application can be very efficient, as it needs little energy

  19. Catchment heterogeneity controls emergent archetype concentration-discharge relationships

    Science.gov (United States)

    Musolff, A.; Fleckenstein, J. H.; Rao, P. S.; Jawitz, J. W.

    2017-12-01

    Relationships between in-stream dissolved solute concentrations (C) and discharge (Q) are often-used indicators of catchment-scale processes and their interference with human activities. Here we analyze observational C-Q relationships from 61 catchments and 8 different solutes across a wide range of land-uses and discharge regimes. This analysis is combined with a parsimonious stochastic modeling approach to test how C-Q relationships arise from spatial heterogeneity in catchment solute sources coupled with different timescales of biogeochemical reactions. The observational data exhibit archetypical dilution, enrichment, and constant C-Q patterns. Moreover, with land-use intensification we find decreasing C variability relative to Q variability (chemostatic export regime). Our model indicates that the dominant driver of emergent C-Q patterns was structured heterogeneity of solute sources implemented as correlation of source concentration to travel time. Regardless of the C-Q pattern, with decreasing source heterogeneity we consistently find lower variability in C than in Q and a dominance of chemostatic export regimes. Here, the variance in exported loads is determined primarily by variance of Q. We conclude that efforts to improve stream water quality and ecological integrity in intensely managed catchments should lead away from landscape homogenization by introducing structured source heterogeneity. References: Musolff, A., J. H. Fleckenstein, P. S. C. Rao, and J. W. Jawitz (2017), Emergent archetype patterns of coupled hydrologic and biogeochemical responses in catchments, Geophys. Res. Lett., 44(9), 4143-4151, doi: 10.1002/2017GL072630.

  20. Sustained diffusive alternating current gliding arc discharge in atmospheric pressure air

    Science.gov (United States)

    Zhu, Jiajian; Gao, Jinlong; Li, Zhongshan; Ehn, Andreas; Aldén, Marcus; Larsson, Anders; Kusano, Yukihiro

    2014-12-01

    Rapid transition from glow discharge to thermal arc has been a common problem in generating stable high-power non-thermal plasmas especially at ambient conditions. A sustained diffusive gliding arc discharge was generated in a large volume in atmospheric pressure air, driven by an alternating current (AC) power source. The plasma column extended beyond the water-cooled stainless steel electrodes and was stabilized by matching the flow speed of the turbulent air jet with the rated output power. Comprehensive investigations were performed using high-speed movies measured over the plasma column, synchronized with simultaneously recorded current and voltage waveforms. Dynamic details of the novel non-equilibrium discharge are revealed, which is characterized by a sinusoidal current waveform with amplitude stabilized at around 200 mA intermediate between thermal arc and glow discharge, shedding light to the governing mechanism of the sustained spark-suppressed AC gliding arc discharge.

  1. Enhanced thermal and structural properties of partially phosphorylated polyvinyl alcohol - Aluminum phosphate (PPVA-Alpo4) nanocomposites with aluminium nitrate source

    Science.gov (United States)

    Saat, Asmalina Mohamed; Johan, Mohd Rafie

    2017-12-01

    Synthesis of AlPO4 nanocomposite depends on the ratio of aluminum to phosphate, method of synthesis and the source for aluminum and phosphate source used. Variation of phosphate and aluminum source used will form multiple equilibria reactions and affected by ions variability and concentration, stoichiometry, temperature during reaction process and especially the precipitation pH. Aluminum nitrate was used to produce a partially phosphorylated poly vinyl alcohol-aluminum phosphate (PPVA-AlPO4) nanocomposite with various nanoparticle shapes, structural and properties. Synthesis of PPVA-AlPO4 nanocomposite with aluminum nitrate shows enhancement of thermal and structural in comparison with pure PVA and modified PPVA. Thermogravimetric (TGA) analysis shows that the weight residue of PPVA-AlPO4 composite was higher than PPVA and PVA. X-ray diffraction (XRD) pattern of PVA shows a single peak broadening after the addition of phosphoric acid. Meanwhile, XRD pattern of PPVA-AlPO4 demonstrates multiple phases of AlPO4 in the nanocomposite. Field Emission Scanning Electron Microscopy (FESEM) confirmed the existence of multiple geometrical phases and nanosize of spherical particles.

  2. Time-Varying Networks of Inter-Ictal Discharging Reveal Epileptogenic Zone.

    Science.gov (United States)

    Zhang, Luyan; Liang, Yi; Li, Fali; Sun, Hongbin; Peng, Wenjing; Du, Peishan; Si, Yajing; Song, Limeng; Yu, Liang; Xu, Peng

    2017-01-01

    The neuronal synchronous discharging may cause an epileptic seizure. Currently, most of the studies conducted to investigate the mechanism of epilepsy are based on EEGs or functional magnetic resonance imaging (fMRI) recorded during the ictal discharging or the resting-state, and few studies have probed into the dynamic patterns during the inter-ictal discharging that are much easier to record in clinical applications. Here, we propose a time-varying network analysis based on adaptive directed transfer function to uncover the dynamic brain network patterns during the inter-ictal discharging. In addition, an algorithm based on the time-varying outflow of information derived from the network analysis is developed to detect the epileptogenic zone. The analysis performed revealed the time-varying network patterns during different stages of inter-ictal discharging; the epileptogenic zone was activated prior to the discharge onset then worked as the source to propagate the activity to other brain regions. Consistence between the epileptogenic zones detected by our proposed approach and the actual epileptogenic zones proved that time-varying network analysis could not only reveal the underlying neural mechanism of epilepsy, but also function as a useful tool in detecting the epileptogenic zone based on the EEGs in the inter-ictal discharging.

  3. Integrative Literature Review: Ascertaining Discharge Readiness for Pediatrics After Anesthesia.

    Science.gov (United States)

    Whitley, Deborah R

    2016-02-01

    Unplanned hospital readmissions after the administration of general anesthesia for ambulatory procedures may contribute to loss of reimbursement and assessment of financial penalties. Pediatric patients represent a unique anesthetic risk. The purpose of this integrative literature review was to ascertain specific criteria used to evaluate discharge readiness for pediatric patients after anesthesia. This study is an integrative review of literature. An integrative literature search was conducted and included literature sources dated January 2008 to November 2013. Key words included pediatric, anesthesia, discharge, criteria, standards, assessment, recovery, postoperative, postanesthesia, scale, score, outpatient, and ambulatory. Eleven literature sources that contributed significantly to the research question were identified. Levels of evidence included three systematic reviews, one randomized controlled trial, three cohort studies, two case series, and two expert opinions. This integrative literature review revealed evidence-based discharge criteria endorsing home readiness for postanesthesia pediatric patients should incorporate consideration for physiological baselines, professional judgment with regard to infant consciousness, and professional practice standards/guidelines. Additionally, identifying and ensuring discharge to a competent adult was considered imperative. Nurses should be aware that frequently used anesthesia scoring systems originated in the 1970s, and this review was unable to locate current literature examining the reliability and validity of their use in conjunction with modern anesthesia-related health care practices. Copyright © 2016 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  4. Diagnostics for electrical discharge light sources : pushing the limits

    NARCIS (Netherlands)

    Zissis, G.; Haverlag, M.

    2010-01-01

    Light sources play an indispensable role in the daily life of any human being. Quality of life, health and urban security related to traffic and crime prevention depend on light and on its quality. In fact, every day approximately 30 billion electric light sources operate worldwide. These electric

  5. Formation of Plasma Structures in Stimulated High-Pressure Microwave Discharge

    National Research Council Canada - National Science Library

    Popov, N. A; Vedenin, P. V

    2003-01-01

    In other papers, the possibility is observed of a jumplike propagation of an stimulated MW discharge toward the radiation source in the form of dipole plasma channels oriented along the electric field vector...

  6. Direct-current converter for gas-discharge lamps

    Science.gov (United States)

    Lutus, P.

    1980-01-01

    Metal/halide and similar gas-discharge lamps are powered from low-voltage dc source using small efficient converter. Converter is useful whenever 60-cycle ac power is not available or where space and weight allocations are limited. Possible applications are offshore platforms, mobile homes, and emergency lighting. Design innovations give supply high reliability and efficiency up to 75 percent.

  7. New design for a microwave discharge lamp.

    Science.gov (United States)

    Glangetas, A

    1980-03-01

    A simple discharge lamp with a microwave cavity fitting inside provides an intense source of VUV resonance radiation for photochemical work inside a vacuum chamber. Good coupling and minimum reabsorption result in better efficiency ( greater, similar1%) and more intense output power (up to 2.5x10(16) quanta s(-1)) than have been achieved previously.

  8. Spatial Characteristics and Driving Factors of Provincial Wastewater Discharge in China.

    Science.gov (United States)

    Chen, Kunlun; Liu, Xiaoqiong; Ding, Lei; Huang, Gengzhi; Li, Zhigang

    2016-12-09

    Based on the increasing pressure on the water environment, this study aims to clarify the overall status of wastewater discharge in China, including the spatio-temporal distribution characteristics of wastewater discharge and its driving factors, so as to provide reference for developing "emission reduction" strategies in China and discuss regional sustainable development and resources environment policies. We utilized the Exploratory Spatial Data Analysis (ESDA) method to analyze the characteristics of the spatio-temporal distribution of the total wastewater discharge among 31 provinces in China from 2002 to 2013. Then, we discussed about the driving factors, affected the wastewater discharge through the Logarithmic Mean Divisia Index (LMDI) method and classified those driving factors. Results indicate that: (1) the total wastewater discharge steadily increased, based on the social economic development, with an average growth rate of 5.3% per year; the domestic wastewater discharge is the main source of total wastewater discharge, and the amount of domestic wastewater discharge is larger than the industrial wastewater discharge. There are many spatial differences of wastewater discharge among provinces via the ESDA method. For example, provinces with high wastewater discharge are mainly the developed coastal provinces such as Jiangsu Province and Guangdong Province. Provinces and their surrounding areas with low wastewater discharge are mainly the undeveloped ones in Northwest China; (2) The dominant factors affecting wastewater discharge are the economy and technological advance; The secondary one is the efficiency of resource utilization, which brings about the unstable effect; population plays a less important role in wastewater discharge. The dominant driving factors affecting wastewater discharge among 31 provinces are divided into three types, including two-factor dominant type, three-factor leading type and four-factor antagonistic type. In addition, the

  9. Tesla's coherent plasma discharge -and- a plan for megavolts at Megahertz

    International Nuclear Information System (INIS)

    Nichson, J.D.

    1987-01-01

    In his lecture on Experiments With Alternate Currents of High Potential and High Frequency before the Institute of Electrical Engineers in London (1892), Tesla reports a discharge through a partially evacuated air tube of 1 meter length and 1 inch diameter. It is characterized by the following properties: (1) The filamentary discharge may be locally displaced by a nearby dielectric body or a magnet. (2) When the filament is released, it demonstrates behaviour similar to that of a string which suspends a weight, including the formation of standing waves with distinct nodes. (3) Its decay time is on the order of 8 minutes. (4) The vibrating filament may be split with a magnet to produce two vibrating filaments. (5) This effect could only be formed with a dynamo-driven coil at low air pressures in the tube. The disruptive discharge coil (coloquially a Tesla Coil) failed to produce the effect with its superior voltage and frequency range. It is here proposed that this phenomenon is related to positive leader formation. A model for this, consistent for AC and DC discharges, is advanced. Also, a novel method for regulation of a nitrogen-filled spark gap will be proposed. It is hoped that this new device will produce smooth, uniform discharges from the Tesla Coil. This, if theory is correct on many points, will reproduce Tesla's coherent plasma at higher pressures in free-standing form, and will allow other novel effects

  10. A global plasma model for reactive deposition of compound films by modulated pulsed power magnetron sputtering discharges

    Science.gov (United States)

    Zheng, B. C.; Wu, Z. L.; Wu, B.; Li, Y. G.; Lei, M. K.

    2017-05-01

    A spatially averaged, time-dependent global plasma model has been developed to describe the reactive deposition of a TiAlSiN thin film by modulated pulsed power magnetron sputtering (MPPMS) discharges in Ar/N2 mixture gas, based on the particle balance and the energy balance in the ionization region, and considering the formation and erosion of the compound at the target surface. The modeling results show that, with increasing the N2 partial pressure from 0% to 40% at a constant working pressure of 0.3 Pa, the electron temperature during the strongly ionized period increases from 4 to 7 eV and the effective power transfer coefficient, which represents the power fraction that effectively heats the electrons and maintains the discharge, increases from about 4% to 7%; with increasing the working pressure from 0.1 to 0.7 Pa at a constant N2 partial pressure of 25%, the electron temperature decreases from 10 to 4 eV and the effective power transfer coefficient decreases from 8% to 5%. Using the modeled plasma parameters to evaluate the kinetic energy of arriving ions, the ion-to-neutral flux ratio of deposited species, and the substrate heating, the variations of process parameters that increase these values lead to an enhanced adatom mobility at the target surface and an increased input energy to the substrate, corresponding to the experimental observation of surface roughness reduction, the microstructure transition from the columnar structure to the dense featureless structure, and the enhancement of phase separation. At higher N2 partial pressure or lower working pressure, the modeling results demonstrate an increase in electron temperature, which shifts the discharge balance of Ti species from Ti+ to Ti2+ and results in a higher return fraction of Ti species, corresponding to the higher Al/Ti ratio of deposited films at these conditions. The modeling results are well correlated with the experimental observation of the composition variation and the microstructure

  11. Translational, rotational, vibrational and electron temperatures of a gliding arc discharge

    DEFF Research Database (Denmark)

    Zhu, Jiajian; Ehn, Andreas; Gao, Jinlong

    2017-01-01

    , 0) band was used to simulate the rotational temperature (Tr) of the gliding arc discharge whereas the NO A–X (1, 0) and (0, 1) bands were used to determine its vibrational temperature (Tv). The instantaneous reduced electric field strength E/N was obtained by simultaneously measuring......Translational, rotational, vibrational and electron temperatures of a gliding arc discharge in atmospheric pressure air were experimentally investigated using in situ, non-intrusive optical diagnostic techniques. The gliding arc discharge was driven by a 35 kHz alternating current (AC) power source...... and operated in a glow-type regime. The two-dimensional distribution of the translational temperature (Tt) of the gliding arc discharge was determined using planar laser-induced Rayleigh scattering. The rotational and vibrational temperatures were obtained by simulating the experimental spectra. The OH A–X (0...

  12. Vessel Sewage Discharges: No-Discharge Zones (NDZs)

    Science.gov (United States)

    States may petition the EPA to establish areas, called no discharge zones (NDZs), where vessel sewage discharges are prohibited. This page describes how NDZs are designated, the types of designations, who enforces them, and how to comply.

  13. Corona discharge ion mobility spectrometry at reduced pressures

    International Nuclear Information System (INIS)

    Tabrizchi, Mahmoud; Rouholahnejad, Fereshteh

    2004-01-01

    Ion mobility spectrometers (IMSs) normally operate at ambient pressure. In this work an IMS cell has been designed and constructed to allow the pressure to be reduced inside the IMS cell. In this cell, corona discharge was employed as the ionization source. Reducing pressure affected both the discharge and the performance of the IMS. The discharge current was observed to increase with reducing pressure while the ignition potential decreased. The ion current received at the collector plate was also increased about 50 times when the pressure was reduced from ambient pressure to 15 Torr. The higher ion current can lead to an extended dynamic range. IMS spectra were recorded at various pressures and the results show that the drift times shift perfectly linear with pressure. This suggests that unlike temperature, pressure correction for ion mobility spectra is as simple as multiplying the drift times by a factor of 760/P

  14. Factory-discharged pharmaceuticals could be a relevant source of aquatic environment contamination: review of evidence and need for knowledge.

    Science.gov (United States)

    Cardoso, Olivier; Porcher, Jean-Marc; Sanchez, Wilfried

    2014-11-01

    Human and veterinary active pharmaceutical ingredients (APIs) are involved in contamination of surface water, ground water, effluents, sediments and biota. Effluents of waste water treatment plants and hospitals are considered as major sources of such contamination. However, recent evidences reveal high concentrations of a large number of APIs in effluents from pharmaceutical factories and in receiving aquatic ecosystems. Moreover, laboratory exposures to these effluents and field experiments reveal various physiological disturbances in exposed aquatic organisms. Also, it seems to be relevant to increase knowledge on this route of contamination but also to develop specific approaches for further environmental monitoring campaigns. The present study summarizes available data related to the impact of pharmaceutical factory discharges on aquatic ecosystem contaminations and presents associated challenges for scientists and environmental managers. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. The effect of external visible light on the breakdown voltage of a long discharge tube

    Science.gov (United States)

    Shishpanov, A. I.; Ionikh, Yu. Z.; Meshchanov, A. V.

    2016-06-01

    The breakdown characteristics of a discharge tube with a configuration typical of gas-discharge light sources and electric-discharge lasers (a so-called "long discharge tube") filled with argon or helium at a pressure of 1 Torr have been investigated. A breakdown has been implemented using positive and negative voltage pulses with a linear leading edge having a slope dU/ dt ~ 10-107 V/s. Visible light from an external source (halogen incandescent lamp) is found to affect the breakdown characteristics. The dependences of the dynamic breakdown voltage of the tube on dU/ dt and on the incident light intensity are measured. The breakdown voltage is found to decrease under irradiation of the high-voltage anode of the tube in a wide range of dU/ dt. A dependence of the effect magnitude on the light intensity and spectrum is obtained. Possible physical mechanisms of this phenomenon are discussed.

  16. Investigating the influence of DNAPL spill characteristics on source zone architecture and mass removal in pool-dominated source zones

    Science.gov (United States)

    Wallace, K. A.; Abriola, L.; Chen, M.; Ramsburg, A.; Pennell, K. D.; Christ, J.

    2009-12-01

    Multiphase, compositional simulators were employed to investigate the spill characteristics and subsurface properties that lead to pool-dominated, dense non-aqueous phase liquid (DNAPL) source zone architectures. DNAPL pools commonly form at textural interfaces where low permeability lenses restrict the vertical migration of DNAPL, allowing for DNAPL to accumulate, reaching high saturation. Significant pooling has been observed in bench-scale experiments and field settings. However, commonly employed numerical simulations rarely predict the pooling suspected in the field. Given the importance of pooling on the efficacy of mass recovery and the down-gradient contaminant signal, it is important to understand the predominant factors affecting the creation of pool-dominated source zones and their subsequent mass discharge. In this work, contaminant properties, spill characteristics and subsurface permeability were varied to investigate the factors contributing to the development of a pool-dominated source zone. DNAPL infiltration and entrapment simulations were conducted in two- and three-dimensional domains using the University of Texas Chemical Compositional (UTCHEM) simulator. A modified version of MT3DMS was then used to simulate DNAPL dissolution and mass discharge. Numerical mesh size was varied to investigate the importance of numerical model parameters on simulations results. The temporal evolution of commonly employed source zone architecture metrics, such as the maximum DNAPL saturation, first and second spatial moments, and fraction of DNAPL mass located in pools, was monitored to determine how the source zone architecture evolved with time. Mass discharge was monitored to identify the link between source zone architecture and down-gradient contaminant flux. Contaminant characteristics and the presence of extensive low permeability lenses appeared to have the most influence on the development of a pool-dominated source zone. The link between DNAPL mass

  17. The relationship between personal growth and psychological functioning in individuals treated in a partial hospital setting.

    Science.gov (United States)

    Danitz, Sara B; Orsillo, Susan M; Beard, Courtney; Björgvinsson, Thröstur

    2018-04-26

    We examined whether current level of personal growth and changes in personal growth predicted treatment response among participants in a partial hospital setting. Patients (N = 269; aged 18-70 years, M = 33.6; 52.4% female) completed measures of personal growth initiative (PGI), valuing personal growth (VPG), and psychological functioning measures at treatment admission and discharge from a partial hospital. PGI and VPG were negatively associated with depression and positively associated with psychological well-being. Baseline PGI and VPG did not predict changes in psychological functioning at discharge. PGI and VPG significantly increased following treatment, and increases were associated with decreases in depression and increases in well-being over and above previously established predictors. Valuing personal growth for intrinsic reasons and active engagement in the personal growth process may be important characteristics to cultivate in psychotherapy as they are malleable and negatively related to depression. © 2018 Wiley Periodicals, Inc.

  18. Bidimensional characterization of the emission spectra in a direct current atmospheric pressure glow discharge

    International Nuclear Information System (INIS)

    Orejas, Jaime; Pisonero, Jorge; Bordel, Nerea; Nelis, Thomas; Guillot, Philippe; Sanz-Medel, Alfredo

    2012-01-01

    An in-house atmospheric pressure glow discharge source, designed to be used as ionization/desorption source for ambient mass spectrometry, has been electrically characterized, and its optical emission spectra evaluated in detail. Electrical characterization showed that the plasma regime can vary from glow discharge to arc discharge depending on operating conditions (i.e. He flow rate and inter electrode distance). Furthermore, bidimensional images of the optical emission of some plasma species using filters as wavelength selectors, were registered from inside and outside the discharge chamber (inner region and afterglow region respectively), showing the spatial distribution of excited species (i.e. He*, N 2 + and O*). These distribution patterns are useful to study the chemistry of the discharge plasma, since different production pathways and different excitation energies affect the presence of these species in the plasma regions. - Highlights: ► An in-house APGD is characterized through electrical and OES measurements. ► Interelectrode distance had more effect on electric regime than He flow rate. ► Internal plume images showed differences on the production pathways for each species. ► Higher interelectrode distances and He flow rates showed better afterglow conditions.

  19. 40 CFR 458.45 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... paragraph, which may be discharged from the carbon black lamp process by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters. ...) EFFLUENT GUIDELINES AND STANDARDS CARBON BLACK MANUFACTURING POINT SOURCE CATEGORY Carbon Black Lamp...

  20. Software System for Finding the Incipient Faults in Power Transformers

    Directory of Open Access Journals (Sweden)

    Nikolina Petkova

    2015-05-01

    Full Text Available In this paper a new software system for finding of incipient faultsis presented.An experiment is made with real measurement of partial discharge(PD that appeared in power transformer. The software system usesacquisition data to define the real state of this transformer. One of the most important criteria for the power transformer’s state is the presence of partial discharges. The wave propagation caused by partial discharge depends on scheme of the winding and construction of the power equipment. In all cases, the PD source had a specific position so the wave measured from the PD –coupling device had a specific waveform. The waveform is different when PDcoupling device is put on a specific place. The waveform and the time of propagation are criteria for the localization of the source of incipient faults in the volume of power transformer.

  1. Dischargers_Example.png | ECHO | US EPA

    Science.gov (United States)

    ECHO, Enforcement and Compliance History Online, provides compliance and enforcement information for approximately 800,000 EPA-regulated facilities nationwide. ECHO includes permit, inspection, violation, enforcement action, and penalty information about facilities regulated under the Clean Air Act (CAA) Stationary Source Program, Clean Water Act (CWA) National Pollutant Elimination Discharge System (NPDES), and/or Resource Conservation and Recovery Act (RCRA). Information also is provided on surrounding demographics when available.

  2. Repetitively pulsed VUV emitter pumped by a barrier discharge in a mixture of helium with heavy water (D{sub 2}O) vapour

    Energy Technology Data Exchange (ETDEWEB)

    Shuaibov, Aleksandr K; Minya, A I; Hrytsak, R V; Gomoki, Z T; Shevera, Igor' V [Uzhgorod National University, Uzhgorod (Ukraine)

    2012-08-31

    A gas-discharge lamp based on a barrier discharge in a He - D{sub 2}O mixture at partial pressures p{sub D2O} = 0.04 - 0.33 kPa and p{sub He} = 10 - 60 kPa is studied. The emission spectrum of the discharge plasma contains mainly the A {yields} X and C {yields} X bands of OD hydroxyl ({lambda} = 144 - 160 nm). The intensities of these bands are optimised by varying the pressure and composition of working mixtures. (laser applications and other topics in quantum electronics)

  3. [Study on the discharge properties of xeon flash lamp and experimental measurement].

    Science.gov (United States)

    Zhao, You-Quan; Miao, Pei-Liang; He, Feng; Gu, Jian; Zhai, Rui-Wei

    2014-07-01

    The Xenon flash lamp is a new type of light source for analytical instrument. The present paper analyzed the discharge process of xenon flash lamp, presented the discharge test system, and conducted experimental measurement of the voltage, current and optical pulse signal in the process of discharge. The results show that in the preliminary discharge, the free electron concentration was at a low level, so the energy was at a low level, then following the gas discharge, numerous free electrons formed in the lamp, resultin in the increase in the concentration of free electrons, therefore discharge current rised rapidly and voltage reduced. The lamp released photons to generate light pulse in the moment of ionic recombination, The pulse xenon lamp light energy output and spectral characteristic is related to electron energy in recombination and combination level of xenon, if the input energy and the energy consumption of the xenon lamp is inconsistent, it will lead to repeated capacitor charging and discharging and produce oscillation waveform. This paper is very useful for understanding the process of xenon lamp discharge, optimizing the driver circuit and the production of xenon flash lamp.

  4. Analysis of nickel-base alloys by Grimm-type glow discharge emission and x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ferreira, N.P.; Strauss, J.A.; Van Maarseveen, I.; Ivanfy, A.B.

    1985-01-01

    Nickel-base alloys can be analysed as satisfactorily as steels by XRF as well as by the Grimm-type source, in spite of problems caused by element combinations, spectral line overlap and the influence of the structure and heat conduction properties on sputtering in the glow discharge source. This extended abstract briefly discusses the use of Grimm-type glow discharge emission and XRF as techniques for the analysis of nickel-base alloys

  5. Ostrich eggshell as calcium source for the synthesis of hydroxyapatite and hydroxyapatite partially substituted with zinc

    Directory of Open Access Journals (Sweden)

    J. R. M. Ferreira

    Full Text Available Abstract In the present study, hydroxyapatite and Zn-substituted hydroxyapatite powders were synthesized using ostrich eggshell as a calcium source. The samples were analyzed by scanning electron microscopy with field emission gun, and X-ray diffraction (XRD to identify the present phases, and X-ray fluorescence spectroscopy for quantitative chemical analysis of the synthesized and heat treated powders. The Fourier transform infrared spectroscopy technique was used before and after heat treatments at 700, 900 and 1100 °C in order to identify the functional groups present, as an additional technique to the XRD analysis. The results presented in this study represent a promising method for synthesis of hydroxyapatite and hydroxyapatite partially substituted with zinc, since the results showed no undesirable phases or impurities in the produced powders. It was observed that Zn-substituted hydroxyapatite showed higher thermal stability, when compared to pure hydroxyapatite.

  6. Numerical Modelling of Electrical Discharges

    International Nuclear Information System (INIS)

    Durán-Olivencia, F J; Pontiga, F; Castellanos, A

    2014-01-01

    The problem of the propagation of an electrical discharge between a spherical electrode and a plane has been solved by means of finite element methods (FEM) using a fluid approximation and assuming weak ionization and local equilibrium with the electric field. The numerical simulation of this type of problems presents the usual difficulties of convection-diffusion-reaction problems, in addition to those associated with the nonlinearities of the charged species velocities, the formation of steep gradients of the electric field and particle densities, and the coexistence of very different temporal scales. The effect of using different temporal discretizations for the numerical integration of the corresponding system of partial differential equations will be here investigated. In particular, the so-called θ-methods will be used, which allows to implement implicit, semi-explicit and fully explicit schemes in a simple way

  7. Ion beam source construction and applications

    International Nuclear Information System (INIS)

    Torab, S.I.R.

    2011-01-01

    The aim of this thesis is to improve the performance of a new shape cold cathode Penning ion source to be suitable for some applications. In this work, many trials have been made to reach the optimum dimensions of the new shape of cold Molybdenum cathode Penning ion source with radial extraction. The high output ion beam can be extracted in a direction transverse to the discharge region. The new shape cold cathode Penning ion source consists of Copper cylindrical hollow anode of 40 mm length, 12 mm diameter and has two similar cone ends of 15 mm length, 22 mm upper cone diameter and 12 mm bottom cone diameter. The two movable Molybdenum cathodes are fixed in Perspex insulator and placed symmetrically at two ends of the anode. The Copper emission disc of 2 mm thickness and has central aperture of different diameters is placed at the middle of the anode for ion beam exit. The inner surface of the emission disc is isolated from the anode by Perspex insulator except an area of diameter 5 mm to confine the electrical discharge in this area. A movable Faraday cup is placed at different distances from the emission electrode aperture and used to collect the output ion beam from the ion source. The working gases are admitted to the ion source through a hole in the anode via a needle valve which placed between the gas cylinder and the ion source. The optimum anode- cathode distance, the uncovered area diameter of the emission disc, the central aperture diameter of the emission electrode, the distance between emission electrode and Faraday cup have been determined using Argon gas. The optimum distances of the ion source were found to be equal to 6 mm, 5 mm, 2.5 mm, and 3 cm respectively where stable discharge current and maximum output ion beam current at low discharge current can be obtained. The discharge characteristics, ion beam characteristics, and the efficiency of the ion source have been measured at different operating conditions and different gas pressures using

  8. Electric discharge for treatment of trace contaminants

    Science.gov (United States)

    Flamm, D. L.; Wydeven, T. J. (Inventor)

    1978-01-01

    A radio frequency glow discharge reactor is described for removing trace oxidizable contaminants from an oxygen bearing atmosphere. The reaction chamber is defined by an inner metal electrode facing a dielectric backed by an outer conductive electrode. In one embodiment, a conductive liquid forms the conductor of an outer electrode and cools the dielectric. A resonator coupled to a variable radio frequency source generates the high voltages for creating a glow discharge in the chamber at a predetermined pressure whereby the trace contaminants are oxidized into a few simple non-toxic products that may be easily recovered. The corresponding process for removal of trace contaminants from an oxygen-bearing atmosphere with high efficiency independent of the concentration level is also disclosed.

  9. Fast capillary discharge facility CAPEX-U as a source of the soft X-ray radiation

    Czech Academy of Sciences Publication Activity Database

    Frolov, Oleksandr; Koláček, Karel; Schmidt, Jiří; Štraus, Jaroslav; Prukner, Václav

    2007-01-01

    Roč. 52, č. 16 (2007), s. 295-295 ISSN 0003-0503. [Annual Meeting of the Division of Plasma Physics/49th./. Orlando , Florida, 12.11.2007-16.11.2007] R&D Projects: GA ČR GA202/06/1324; GA AV ČR KJB100430702; GA AV ČR KAN300100702; GA MŠk 1P04LA235 Institutional research plan: CEZ:AV0Z20430508 Keywords : Capillary discharge * x-ray * laser * laser-triggered * spark gap * breakdown * plasma Subject RIV: BL - Plasma and Gas Discharge Physics http://meetings.aps.org/Meeting/DPP07/Content/901

  10. High energy XeBr electric discharge laser

    Science.gov (United States)

    Sze, Robert C.; Scott, Peter B.

    1981-01-01

    A high energy XeBr laser for producing coherent radiation at 282 nm. The XeBr laser utilizes an electric discharge as the excitation source to minimize formation of molecular ions thereby minimizing absorption of laser radiation by the active medium. Additionally, HBr is used as the halogen donor which undergoes harpooning reactions with Xe.sub.M * to form XeBr*.

  11. Application of Discharges in Vapor of Evaporated Metals for the Film Deposition from the Ionized Stream

    International Nuclear Information System (INIS)

    Kostin, E.G.

    2006-01-01

    results of researches of the discharge device for ionization of the vapor of solid materials are presented. Evaporation of a material was made by an electron gun with a deviation of a beam on 180 degree. Diode type discharge device for ionization was placed above a surface of evaporated metal and was in a longitudinal adjustable magnetic field. Discharge was carried out in crossed electric and magnetic fields. Partial ionization of the vapor was made by primary and secondary electrons of the gun in a vapor cloud above evaporated substance. Physical properties and structure of the films. The comparative analysis of the films properties, besieged in conditions of influence of bombardment by ions of evaporated metal were studied depending on energy and the contents of ions in a stream of particles on a substrate

  12. Collector floating potentials in a discharge plasma

    International Nuclear Information System (INIS)

    Cercek, M.; Gyergyek, T.

    1999-01-01

    We present the results of a study on electrode floating potential formation in a hot-cathode discharge plasma. The electron component of the plasma is composed from two populations. The high temperature component develops from primary electrons and the cool component from secondary electrons born by ionisation of cold neutral gas. A static, kinetic plasma-sheath model is use to calculate the pre-sheath potential and the floating potential of the electrode. For hot primary electrons a truncated Maxwellian distribution is assumed. The plasma system is also modelled numerically with a dynamic, electrostatic particle simulation. The plasma source injects temporally equal fluxes of ions and electrons with half-Maxwellian velocities. Again, the hot electron distribution is truncated in the high velocity tail. The plasma parameters, such as ion temperature and mass, electron temperatures, discharge voltages, etc. correspond to experimental values. The experimental measurements of the electrode floating potential are performed in weakly magnetised plasma produced with hot cathode discharge in argon gas. Theoretical, simulation and experimental results are compared and they agree very well.(author)

  13. Ca-doped LTO using waste eggshells as Ca source to improve the discharge capacity of anode material for lithium-ion battery

    Science.gov (United States)

    Setiawan, D.; Subhan, A.; Saptari, S. A.

    2017-07-01

    The necessity of high charge-discharge capacity lithium-ion battery becomes very urgent due to its applications demand. Several researches have been done to meet the demand including Ca doping on Li4Ti5O12 for anode material of lithium-ion batteries. Ca-doped Li4Ti5O12 (LTO) in the form of Li4-xCaxTi5O12 (x = 0, 0.05, 0.075, and 0.1) have been synthesized using simple solid state reaction. The materials preparation involved waste eggshells in the form of CaCO3 as Ca source. The structure and capacity of as-prepared samples were characterized using X-Ray Diffractometer and Cyclic Voltametry. X-Ray Diffractometer characterization revealed that all amount of dopant had entered the lattice structure of LTO successfully. The crystalline sizes were obtained by using Scherrer equation. No significant differences are detected in lattice parameters (˜8.35 Å) and crystalline sizes (˜27 nm) between all samples. Cyclic Voltametry characterization shows that Li4-xCaxTi5O12 (x = 0.05) has highest charge-discharge capacity of 177.14 mAh/g and 181.92 mAh/g, respectively. Redox-potentials of samples show no significant differences with the average of 1.589 V.

  14. Properties of water surface discharge at different pulse repetition rates

    International Nuclear Information System (INIS)

    Ruma,; Yoshihara, K.; Hosseini, S. H. R.; Sakugawa, T.; Akiyama, H.; Akiyama, M.; Lukeš, P.

    2014-01-01

    The properties of water surface discharge plasma for variety of pulse repetition rates are investigated. A magnetic pulse compression (MPC) pulsed power modulator able to deliver pulse repetition rates up to 1000 Hz, with 0.5 J per pulse energy output at 25 kV, was used as the pulsed power source. Positive pulse with a point-to-plane electrode configuration was used for the experiments. The concentration and production yield of hydrogen peroxide (H 2 O 2 ) were quantitatively measured and orange II organic dye was treated, to evaluate the chemical properties of the discharge reactor. Experimental results show that the physical and chemical properties of water surface discharge are not influenced by pulse repetition rate, very different from those observed for under water discharge. The production yield of H 2 O 2 and degradation rate per pulse of the dye did not significantly vary at different pulse repetition rates under a constant discharge mode on water surface. In addition, the solution temperature, pH, and conductivity for both water surface and underwater discharge reactors were measured to compare their plasma properties for different pulse repetition rates. The results confirm that surface discharge can be employed at high pulse repetition rates as a reliable and advantageous method for industrial and environmental decontamination applications.

  15. Negative Ion Sources: Magnetron and Penning

    CERN Document Server

    Faircloth, D.C.

    2013-12-16

    The history of the magnetron and Penning electrode geometry is briefly outlined. Plasma generation by electrical discharge-driven electron impact ionization is described and the basic physics of plasma and electrodes relevant to magnetron and Penning discharges are explained. Negative ions and their applications are introduced, along with their production mechanisms. Caesium and surface production of negative ions are detailed. Technical details of how to build magnetron and Penning surface plasma sources are given, along with examples of specific sources from around the world. Failure modes are listed and lifetimes compared.

  16. Negative Ion Sources: Magnetron and Penning

    International Nuclear Information System (INIS)

    Faircloth, D C

    2013-01-01

    The history of the magnetron and Penning electrode geometry is briefly outlined. Plasma generation by electrical discharge-driven electron impact ionization is described and the basic physics of plasma and electrodes relevant to magnetron and Penning discharges are explained. Negative ions and their applications are introduced, along with their production mechanisms. Caesium and surface production of negative ions are detailed. Technical details of how to build magnetron and Penning surface plasma sources are given, along with examples of specific sources from around the world. Failure modes are listed and lifetimes compared. (author)

  17. High efficiency atomic hydrogen source

    International Nuclear Information System (INIS)

    Lagomarsino, V.; Bassi, D.; Bertok, E.; De Paz, M.; Tommasini, F.

    1974-01-01

    This work presents preliminary results of research intended to produce a M.W. discharge atomic hydrogen source with good dissociation at pressures larger than 10 torr. Analysis of the recombination process at these pressures shows that the volume recombination by three body collisions may be more important than wall recombination or loss of atoms by diffusion and flow outside the discharge region

  18. State waste discharge permit application for cooling water and condensate discharges

    Energy Technology Data Exchange (ETDEWEB)

    Haggard, R.D.

    1996-08-12

    The following presents the Categorical State Waste Discharge Permit (SWDP) Application for the Cooling Water and Condensate Discharges on the Hanford Site. This application is intended to cover existing cooling water and condensate discharges as well as similar future discharges meeting the criteria set forth in this document.

  19. Glow plasma jet - experimental study of a transferred atmospheric pressure glow discharge

    International Nuclear Information System (INIS)

    Guerra-Mutis, Marlon H; U, Carlos V Pelaez; H, Rafael Cabanzo

    2003-01-01

    In this paper we present the experimental study of a glow plasma jet (GPJ) obtained from a transferred atmospheric pressure glow discharge (APGD) operating at 60 Hz. The characterization of the emission spectra for both electrical discharges is presented and the electrical circuit features for APGD generation are discussed. The potentiality of GPJ as a source of active species for depletion of contaminants in liquid hydrocarbon fractions is also established

  20. The transition mechanism from a symmetric single period discharge to a period-doubling discharge in atmospheric helium dielectric-barrier discharge

    International Nuclear Information System (INIS)

    Zhang, Dingzong; Wang, Yanhui; Wang, Dezhen

    2013-01-01

    Period-doubling and chaos phenomenon have been frequently observed in atmospheric-pressure dielectric-barrier discharges. However, how a normal single period discharge bifurcates into period-doubling state is still unclear. In this paper, by changing the driving frequency, we study numerically the transition mechanisms from a normal single period discharge to a period-doubling state using a one-dimensional self-consistent fluid model. The results show that before a discharge bifurcates into a period-doubling state, it first deviates from its normal operation and transforms into an asymmetric single period discharge mode. Then the weaker discharge in this asymmetric discharge will be enhanced gradually with increasing of the frequency until it makes the subsequent discharge weaken and results in the discharge entering a period-doubling state. In the whole transition process, the spatial distribution of the charged particle density and the electric field plays a definitive role. The conclusions are further confirmed by changing the gap width and the amplitude of the applied voltage

  1. The transition mechanism from a symmetric single period discharge to a period-doubling discharge in atmospheric helium dielectric-barrier discharge

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Dingzong; Wang, Yanhui; Wang, Dezhen [School of Physics and Optoelectronic Technology, Dalian University of Technology, Dalian 116024 (China)

    2013-06-15

    Period-doubling and chaos phenomenon have been frequently observed in atmospheric-pressure dielectric-barrier discharges. However, how a normal single period discharge bifurcates into period-doubling state is still unclear. In this paper, by changing the driving frequency, we study numerically the transition mechanisms from a normal single period discharge to a period-doubling state using a one-dimensional self-consistent fluid model. The results show that before a discharge bifurcates into a period-doubling state, it first deviates from its normal operation and transforms into an asymmetric single period discharge mode. Then the weaker discharge in this asymmetric discharge will be enhanced gradually with increasing of the frequency until it makes the subsequent discharge weaken and results in the discharge entering a period-doubling state. In the whole transition process, the spatial distribution of the charged particle density and the electric field plays a definitive role. The conclusions are further confirmed by changing the gap width and the amplitude of the applied voltage.

  2. Pharmaceutical manufacturing facility discharges can substantially increase the pharmaceutical load to U.S. wastewaters

    Science.gov (United States)

    Scott, Tia-Marie; Phillips, Patrick J.; Kolpin, Dana W.; Colella, Kaitlyn M.; Furlong, Edward T.; Foreman, William T.; Gray, James L.

    2018-01-01

    Discharges from pharmaceutical manufacturing facilities (PMFs) previously have been identified as important sources of pharmaceuticals to the environment. Yet few studies are available to establish the influence of PMFs on the pharmaceutical source contribution to wastewater treatment plants (WWTPs) and waterways at the national scale. Consequently, a national network of 13 WWTPs receiving PMF discharges, six WWTPs with no PMF input, and one WWTP that transitioned through a PMF closure were selected from across the United States to assess the influence of PMF inputs on pharmaceutical loading to WWTPs. Effluent samples were analyzed for 120 pharmaceuticals and pharmaceutical degradates. Of these, 33 pharmaceuticals had concentrations substantially higher in PMF-influenced effluent (maximum 555,000 ng/L) compared to effluent from control sites (maximum 175 ng/L). Concentrations in WWTP receiving PMF input are variable, as discharges from PMFs are episodic, indicating that production activities can vary substantially over relatively short (several months) periods and have the potential to rapidly transition to other pharmaceutical products. Results show that PMFs are an important, national-scale source of pharmaceuticals to the environment.

  3. Hysterectomy - vaginal - discharge

    Science.gov (United States)

    Vaginal hysterectomy - discharge; Laparoscopically assisted vaginal hysterectomy - discharge; LAVH - discharge ... you were in the hospital, you had a vaginal hysterectomy. Your surgeon made a cut in your ...

  4. Selected hydraulic test analysis techniques for constant-rate discharge tests

    International Nuclear Information System (INIS)

    Spane, F.A. Jr.

    1993-03-01

    The constant-rate discharge test is the principal field method used in hydrogeologic investigations for characterizing the hydraulic properties of aquifers. To implement this test, the aquifer is stressed by withdrawing ground water from a well, by using a downhole pump. Discharge during the withdrawal period is regulated and maintained at a constant rate. Water-level response within the well is monitored during the active pumping phase (i.e., drawdown) and during the subsequent recovery phase following termination of pumping. The analysis of drawdown and recovery response within the stress well (and any monitored, nearby observation wells) provides a means for estimating the hydraulic properties of the tested aquifer, as well as discerning formational and nonformational flow conditions (e.g., wellbore storage, wellbore damage, presence of boundaries, etc.). Standard analytical methods that are used for constant-rate pumping tests include both log-log type-curve matching and semi-log straight-line methods. This report presents a current ''state of the art'' review of selected transient analysis procedures for constant-rate discharge tests. Specific topics examined include: analytical methods for constant-rate discharge tests conducted within confined and unconfined aquifers; effects of various nonideal formation factors (e.g., anisotropy, hydrologic boundaries) and well construction conditions (e.g., partial penetration, wellbore storage) on constant-rate test response; and the use of pressure derivatives in diagnostic analysis for the identification of specific formation, well construction, and boundary conditions

  5. Catchment tracers reveal discharge, recharge and sources of groundwater-borne pollutants in a novel lake modelling approach

    Science.gov (United States)

    Kristensen, Emil; Madsen-Østerbye, Mikkel; Massicotte, Philippe; Pedersen, Ole; Markager, Stiig; Kragh, Theis

    2018-02-01

    Groundwater-borne contaminants such as nutrients, dissolved organic carbon (DOC), coloured dissolved organic matter (CDOM) and pesticides can have an impact the biological quality of lakes. The sources of pollutants can, however, be difficult to identify due to high heterogeneity in groundwater flow patterns. This study presents a novel approach for fast hydrological surveys of small groundwater-fed lakes using multiple groundwater-borne tracers. Water samples were collected from the lake and temporary groundwater wells, installed every 50 m within a distance of 5-45 m to the shore, were analysed for tracer concentrations of CDOM, DOC, total dissolved nitrogen (TDN, groundwater only), total nitrogen (TN, lake only), total dissolved phosphorus (TDP, groundwater only), total phosphorus (TP, lake only), δ18O / δ16O isotope ratios and fluorescent dissolved organic matter (FDOM) components derived from parallel factor analysis (PARAFAC). The isolation of groundwater recharge areas was based on δ18O measurements and areas with a high groundwater recharge rate were identified using a microbially influenced FDOM component. Groundwater discharge sites and the fractions of water delivered from the individual sites were isolated with the Community Assembly via Trait Selection model (CATS). The CATS model utilized tracer measurements of TDP, TDN, DOC and CDOM from the groundwater samples and related these to the tracer measurements of TN, TP, DOC and CDOM in the lake. A direct comparison between the lake and the inflowing groundwater was possible as degradation rates of the tracers in the lake were taken into account and related to a range of water retention times (WRTs) of the lake (0.25-3.5 years in 0.25-year increments). These estimations showed that WRTs above 2 years required a higher tracer concentration of inflowing water than found in any of the groundwater wells around the lake. From the estimations of inflowing tracer concentration, the CATS model isolated

  6. Assessing TCE source bioremediation by geostatistical analysis of a flux fence.

    Science.gov (United States)

    Cai, Zuansi; Wilson, Ryan D; Lerner, David N

    2012-01-01

    Mass discharge across transect planes is increasingly used as a metric for performance assessment of in situ groundwater remediation systems. Mass discharge estimates using concentrations measured in multilevel transects are often made by assuming a uniform flow field, and uncertainty contributions from spatial concentration and flow field variability are often overlooked. We extend our recently developed geostatistical approach to estimate mass discharge using transect data of concentration and hydraulic conductivity, so accounting for the spatial variability of both datasets. The magnitude and uncertainty of mass discharge were quantified by conditional simulation. An important benefit of the approach is that uncertainty is quantified as an integral part of the mass discharge estimate. We use this approach for performance assessment of a bioremediation experiment of a trichloroethene (TCE) source zone. Analyses of dissolved parent and daughter compounds demonstrated that the engineered bioremediation has elevated the degradation rate of TCE, resulting in a two-thirds reduction in the TCE mass discharge from the source zone. The biologically enhanced dissolution of TCE was not significant (~5%), and was less than expected. However, the discharges of the daughter products cis-1,2, dichloroethene (cDCE) and vinyl chloride (VC) increased, probably because of the rapid transformation of TCE from the source zone to the measurement transect. This suggests that enhancing the biodegradation of cDCE and VC will be crucial to successful engineered bioremediation of TCE source zones. © 2012, The Author(s). Ground Water © 2012, National Ground Water Association.

  7. Characterization of polarized electrons coming from helium post-discharge source; Caracterisation du faisceau d`electrons polarises issus d`une source a post-decharge d`helium

    Energy Technology Data Exchange (ETDEWEB)

    Zerhouni, R.O.

    1996-02-01

    The objective of this thesis is the characterization of the polarized electron source developed at Orsay and foreseen to be coupled to a cw accelerator for nuclear physics experiments. The principle of operation of this source relies on the chemo-ionization reaction between optically aligned helium triplet metastable atoms and CO{sub 2} molecules. The helium metastable atoms are generated by injection of purified helium into a 2,45 GHz micro-wave discharge. They are optically pumped using two beams of 1,083 micro-meter resonant radiation, one circularly and the other linearly polarized. Both beams are delivered by a high power LNA laser. The metastable atomic beam interacts with a dense (10{sup 13} cm {sup -3}) spin singlet CO{sub 2} target. A fraction of the produced polarized electrons is extracted and collimated by electrostatic optics. Either to the Mott polarimeter or to the Faraday cup in order to measure the electron polarization and extracted current. For current intensities of 100 micro-Amperes, the electronic polarization reaches 62 % and shows that this type of source has reached the same high competitive level as the most performing GaAs ones. Additionally, the optical properties of the extracted beam are found to be excellent. These properties (energy spread and emittance) reflect the electron energy distribution at the chemo-ionization region. The upper limit of the beam`s energy spread is 0.24 eV since this value characterizes our instrumental resolution. The average normalized emittance is found to be 0.6 pi mm-mrad. These values satisfy the requirements of most cw accelerators. All the measurements were performed at low electron beam transport energies (1 to 2 KeV). (author). 105 refs., 54 figs., 4 tabs.

  8. Hip fracture - discharge

    Science.gov (United States)

    ... neck fracture repair - discharge; Trochanteric fracture repair - discharge; Hip pinning surgery - discharge ... in the hospital for surgery to repair a hip fracture, a break in the upper part of ...

  9. Surface modification by EUV laser beam based on capillary discharge

    Czech Academy of Sciences Publication Activity Database

    Frolov, Oleksandr; Koláček, Karel; Schmidt, Jiří; Štraus, Jaroslav; Prukner, Václav; Shukurov, A.

    -, č. 58 (2011), s. 484-487 ISSN 2010-376X. [International Conference on Fusion and Plasma Physics. Bali, Indonésie, 26.10.2011-28.10.2011] R&D Projects: GA AV ČR KAN300100702; GA MŠk LA08024; GA MŠk(CZ) LC528 Institutional research plan: CEZ:AV0Z20430508 Keywords : soft x-ray * EUV * laser * radiation * source * capillary * discharge * plasma * ablation * surface modification Subject RIV: BL - Plasma and Gas Discharge Physics http://www.waset.org/journals/waset/v58/v58-99.pdf

  10. Uncertainty in river discharge observations: a quantitative analysis

    Directory of Open Access Journals (Sweden)

    G. Di Baldassarre

    2009-06-01

    Full Text Available This study proposes a framework for analysing and quantifying the uncertainty of river flow data. Such uncertainty is often considered to be negligible with respect to other approximations affecting hydrological studies. Actually, given that river discharge data are usually obtained by means of the so-called rating curve method, a number of different sources of error affect the derived observations. These include: errors in measurements of river stage and discharge utilised to parameterise the rating curve, interpolation and extrapolation error of the rating curve, presence of unsteady flow conditions, and seasonal variations of the state of the vegetation (i.e. roughness. This study aims at analysing these sources of uncertainty using an original methodology. The novelty of the proposed framework lies in the estimation of rating curve uncertainty, which is based on hydraulic simulations. These latter are carried out on a reach of the Po River (Italy by means of a one-dimensional (1-D hydraulic model code (HEC-RAS. The results of the study show that errors in river flow data are indeed far from negligible.

  11. Mobilization of radionuclides from sediments. Potential sources to Arctic waters

    International Nuclear Information System (INIS)

    Oughton, D.H.; Boerretzen, P.; Mathisen, B.; Salbu, B.; Tronstad, E.

    1995-01-01

    Contaminated soils and sediments can act as secondary sources of radionuclides to Arctic waters. In cases where the original source of contamination has ceased or been greatly reduced (e.g., weapons' testing, waste discharges from Mayak and Sellafield) remobilization of radionuclides from preciously contaminated sediments increases in importance. With respect to Arctic waters, potential secondary sources include sediments contaminated by weapons' testing, by discharges from nuclear installations to seawater, e.g., the Irish Sea, or by leakages from dumped waste containers. The major land-based source is run-off from soils and transport from sediments in the catchment areas of the Ob and Yenisey rivers, including those contaminated by Mayak discharges. Remobilization of radionuclides is often described as a secondary source of contamination. Whereas primary sources of man-made radionuclides tend to be point sources, secondary sources are usually more diffuse. Experiments were carried out on marine (Kara Sea, Irish Sea, Stepovogo and Abrosimov Fjords), estuarine (Ob-Yenisey) and dirty ice sediments. Total 137 Cs and 90 Sr concentrations were determined using standard radiochemical techniques. Tracer studies using 134 Cs and 85 Sr were used to investigate the kinetics of radionuclide adsorption and desorption. It is concluded that 90 Sr is much less strongly bound to marine sediments than 137 Cs, and can be chemically mobilized through ion exchange with elements is seawater. Radiocaesium is strongly and rapidly fixed to sediments. Discharges of 137 Cs to surface sediments (i.e., from dumped containers) would be expected to be retained in sediments to a greater extent than discharges to sea-waters. Physical mobilization of sediments, for example resuspension, may be of more importance for transport of 137 Cs than for 90 Sr. 7 refs., 4 figs

  12. The regulation of technetium-99 discharges at Sellafield

    International Nuclear Information System (INIS)

    Mayall, A.

    2002-01-01

    The reprocessing of spent Magnox fuel at BNFL Sellafield produces a liquid waste concentrate containing technetium-99 and other, more radiotoxic, radionuclides such as plutonium and americium. The concentrate is known as medium active concentrate (MAC). Prior to 1981, MAC was discharged to sea untreated after several years' storage, during which short-lived radionuclides underwent radioactive decay. In the early 1980s, discharges of MAC were suspended and it was retained in storage tanks, pending the construction of a plant to remove the radionuclides of greatest radiological concern (these did not include technetium- 99). The Enhanced Actinide Removal Plant started operation in 1994 and began to clear the backlog of stored waste MAC, as well as current arisings from Magnox reprocessing. As a consequence technetium-99 was once more discharged to sea. Subsequently, concentrations of this radionuclide in the marine environment increased. In particular, there was a significant increase in the concentration of technetium-99 in lobster in the Irish Sea. An increase in technetium-99 has also been detected at locations far distant from Sellafield, e.g. in Scandinavian coastal waters, albeit at very low concentrations. This dispersal of technetium- 99 throughout the Irish Sea and further afield has therefore caused concern, although the radiological impact is low. This paper examines the nature and source of the technetium-99 in sea discharges at Sellafield and the levels of past and current discharges as well as their impact. It goes on to describe the Environment Agency's recent proposals on the future regulation of technetium-99 discharges and how these should lead to substantial reductions in not only technetium-99 discharges, but also of other radionuclides such as caesium-137 and strontium-90. (author)

  13. Bidimensional characterization of the emission spectra in a direct current atmospheric pressure glow discharge

    Energy Technology Data Exchange (ETDEWEB)

    Orejas, Jaime [University of Oviedo, Department of Physics, C/ Gonzazlez Quiros S/N, Mieres (Spain); Pisonero, Jorge, E-mail: pisonerojorge@uniovi.es [University of Oviedo, Department of Physics, C/ Gonzazlez Quiros S/N, Mieres (Spain); Bordel, Nerea [University of Oviedo, Department of Physics, C/ Gonzazlez Quiros S/N, Mieres (Spain); Nelis, Thomas [Bern University of Applied Sciences, Quellgasse 21, 2501 Bienne (Switzerland); Guillot, Philippe [DPHE, CUFR J. F. Champollion, Universite de Toulouse, Place de Verdun, Albi (France); Sanz-Medel, Alfredo, E-mail: asm@uniovi.es [University of Oviedo, Department of Physical and Analytical Chemistry, C/ Julian Claveria 8, Oviedo (Spain)

    2012-10-15

    An in-house atmospheric pressure glow discharge source, designed to be used as ionization/desorption source for ambient mass spectrometry, has been electrically characterized, and its optical emission spectra evaluated in detail. Electrical characterization showed that the plasma regime can vary from glow discharge to arc discharge depending on operating conditions (i.e. He flow rate and inter electrode distance). Furthermore, bidimensional images of the optical emission of some plasma species using filters as wavelength selectors, were registered from inside and outside the discharge chamber (inner region and afterglow region respectively), showing the spatial distribution of excited species (i.e. He*, N{sub 2}{sup +} and O*). These distribution patterns are useful to study the chemistry of the discharge plasma, since different production pathways and different excitation energies affect the presence of these species in the plasma regions. - Highlights: Black-Right-Pointing-Pointer An in-house APGD is characterized through electrical and OES measurements. Black-Right-Pointing-Pointer Interelectrode distance had more effect on electric regime than He flow rate. Black-Right-Pointing-Pointer Internal plume images showed differences on the production pathways for each species. Black-Right-Pointing-Pointer Higher interelectrode distances and He flow rates showed better afterglow conditions.

  14. Auxiliary glow discharge in the trigger unit of a hollow-cathode thyratron

    Energy Technology Data Exchange (ETDEWEB)

    Korolev, Yu. D.; Landl, N. V., E-mail: landl@lnp.hcei.tsc.ru; Geyman, V. G.; Frants, O. B.; Shemyakin, I. A.; Nekhoroshev, V. O. [Russian Academy of Sciences, Institute of High-Current Electronics, Siberian Branch (Russian Federation)

    2016-08-15

    Results from studies of a low-current glow discharge with a hollow cathode are presented. A specific feature of the discharge conditions was that a highly emissive tablet containing cesium carbonate was placed in the cathode cavity. In the absence of a tablet, the discharge ignition voltage was typically ≥3.5 kV, while the burning voltage was in the range of 500–600 V. The use of the tablet made it possible to decrease the ignition voltage to 280 V and maintain the discharge burning voltage at a level of about 130 V. A model of the current sustainment in a hollow-cathode discharge is proposed. Instead of the conventional secondary emission yield, the model uses a generalized emission yield that takes into account not only ion bombardment of the cathode, but also the emission current from an external source. The model is used to interpret the observed current−voltage characteristics. The results of calculations agree well with the experimental data. It is shown that, in some discharge modes, the external emission current from the cathode can reach 25% of the total discharge current.

  15. Accuracy Improvement of Discharge Measurement with Modification of Distance Made Good Heading

    Directory of Open Access Journals (Sweden)

    Jongkook Lee

    2016-01-01

    Full Text Available Remote control boats equipped with an Acoustic Doppler Current Profiler (ADCP are widely accepted and have been welcomed by many hydrologists for water discharge, velocity profile, and bathymetry measurements. The advantages of this technique include high productivity, fast measurements, operator safety, and high accuracy. However, there are concerns about controlling and operating a remote boat to achieve measurement goals, especially during extreme events such as floods. When performing river discharge measurements, the main error source stems from the boat path. Due to the rapid flow in a flood condition, the boat path is not regular and this can cause errors in discharge measurements. Therefore, improvement of discharge measurements requires modification of boat path. As a result, the measurement errors in flood flow conditions are 12.3–21.8% before the modification of boat path, but 1.2–3.7% after the DMG modification of boat path. And it is considered that the modified discharges are very close to the observed discharge in the flood flow conditions. In this study, through the distance made good (DMG modification of the boat path, a comprehensive discharge measurement with high accuracy can be achieved.

  16. Ankle replacement - discharge

    Science.gov (United States)

    ... total - discharge; Total ankle arthroplasty - discharge; Endoprosthetic ankle replacement - discharge; Osteoarthritis - ankle ... You had an ankle replacement. Your surgeon removed and reshaped ... an artificial ankle joint. You received pain medicine and were ...

  17. Asthma - child - discharge

    Science.gov (United States)

    Pediatric asthma - discharge; Wheezing - discharge; Reactive airway disease - discharge ... Your child has asthma , which causes the airways of the lungs to swell and narrow. In the hospital, the doctors and nurses helped ...

  18. REE and Isotopic Compositions of Lunar Basalts Demonstrate Partial Melting of Hybridized Mantle Sources after Cumulate Overturn is Required

    Science.gov (United States)

    Dygert, N. J.; Liang, Y.

    2017-12-01

    Lunar basalts maintain an important record of the composition of the lunar interior. Much of our understanding of the Moon's early evolution comes from studying their petrogenesis. Recent experimental work has advanced our knowledge of major and trace element fractionation during lunar magma ocean (LMO) crystallization [e.g., 1-3], which produced heterogeneous basalt sources in the Moon's mantle. With the new experimental constraints, we can evaluate isotopic and trace element signatures in lunar basalts in unprecedented detail, refining inferences about the Moon's dynamic history. Two petrogenetic models are invoked to explain the compositions of the basalts. The assimilation model argues they formed as primitive melts of early LMO cumulates that assimilated late LMO cumulates as they migrated upward. The cumulate overturn model argues that dense LMO cumulates sank into the lunar interior, producing hybridized sources that melted to form the basalts. Here we compare predicted Ce/Yb and Hf and Nd isotopes of partial melts of LMO cumulates with measured compositions of lunar basalts to evaluate whether they could have formed by end-member petrogenetic models. LMO crystallization models suggest all LMO cumulates have chondrite normalized Ce/Yb 1.5; these could not have formed by assimilation of any LMO cumulate or residual liquid (or KREEP basalt, which has isotopically negative ɛNd and ɛHf). In contrast, basalt REE patterns and isotopes can easily be modeled assuming partial melting of hybridized mantle sources, indicating overturn may be required. A chemical requirement for overturn independently confirms that late LMO cumulates are sufficiently low in viscosity to sink into the lunar interior, as suggested by recent rock deformation experiments [4]. Overturned, low viscosity late LMO cumulates would be relatively stable around the core [5]. High Ce/Yb basalts require that overturned cumulates were mixed back into the overlying mantle by convection within a few

  19. Collective doses from airborne discharges by the UK nuclear industry

    International Nuclear Information System (INIS)

    Kelly, G.N.

    1981-01-01

    Small quantities of radionuclides are discharged in airborne effluents during the normal operation of nuclear installations. The dispersion of these nuclides in the atmosphere and their subsequent transfer through various sectors of the environment leads to the irradiation of the population. The collective dose to the UK population from airborne discharges in one particular year, 1978, from UK nuclear installations is estimated. The discharges in that year are typical of those in the recent past. Consideration is given to the contribution made by each type of establishment (eg, nuclear power stations, reprocessing plants) and the nuclides which contribute significantly to the collective dose are identified. The distributions of the collective dose in time and among individuals in the exposed population are important features in determining the significance attached to it and both aspects are discussed. The collective dose can be used as a measure of the health detriment associated with the discharge practices considered and is one of several quantities to be taken into account in assessing them. The collective doses from airborne discharges are finally contrasted with those from other sources of exposure of the population. (author)

  20. Gas-dynamic effects in the interaction of a motionless optical pulsating discharge with gas

    International Nuclear Information System (INIS)

    Tishchenko, V N; Grachev, G N; Smirnov, A L; Pavlov, A A; Pavlov, A A; Golubev, M P

    2008-01-01

    The effect of energy removal from the combustion zone of a motionless optical pulsating discharge in the horizontal direction along the axis of a repetitively pulsed laser beam producing the discharge is discovered. The directivity diagram of a hot gas flow is formed during the action of hundreds of pulses. The effect is observed for short pulse durations, when the discharge efficiently generates shock waves. For long pulse durations, the heated gas propagates upward, as in a thermal source. (laser applications and other topics in quantum electronics)