WorldWideScience

Sample records for partial discharge pd

  1. Partial discharge testing: a progress report. Statistical evaluation of PD data

    International Nuclear Information System (INIS)

    Warren, V.; Allan, J.

    2005-01-01

    It has long been known that comparing the partial discharge results obtained from a single machine is a valuable tool enabling companies to observe the gradual deterioration of a machine stator winding and thus plan appropriate maintenance for the machine. In 1998, at the annual Iris Rotating Machines Conference (IRMC), a paper was presented that compared thousands of PD test results to establish the criteria for comparing results from different machines and the expected PD levels. At subsequent annual Iris conferences, using similar analytical procedures, papers were presented that supported the previous criteria and: in 1999, established sensor location as an additional criterion; in 2000, evaluated the effect of insulation type and age on PD activity; in 2001, evaluated the effect of manufacturer on PD activity; in 2002, evaluated the effect of operating pressure for hydrogen-cooled machines; in 2003, evaluated the effect of insulation type and setting Trac alarms; in 2004, re-evaluated the effect of manufacturer on PD activity. Before going further in database analysis procedures, it would be prudent to statistically evaluate the anecdotal evidence observed to date. The goal was to determine which variables of machine conditions greatly influenced the PD results and which didn't. Therefore, this year's paper looks at the impact of operating voltage, machine type and winding type on the test results for air-cooled machines. Because of resource constraints, only data collected through 2003 was used; however, as before, it is still standardized for frequency bandwidth and pruned to include only full-load-hot (FLH) results collected for one sensor on operating machines. All questionable data, or data from off-line testing or unusual machine conditions was excluded, leaving 6824 results. Calibration of on-line PD test results is impractical; therefore, only results obtained using the same method of data collection and noise separation techniques are compared. For

  2. THE ANALYSIS OF PARTIAL DISCHARGE (PD FROM ELECTRICAL TREEING IN LINEAR LOW DENSITY POLYETHYLENE (LLDPE AND HIGH DENSITY POLYETHYLENE (HDPE

    Directory of Open Access Journals (Sweden)

    Hermawan Hermawan

    2012-02-01

    Full Text Available Recently, the transmission of electric energy has been developed by insulated cable. The suitable materialas an insulated cable is LLDPE and HDPE. In order to understand the quality of insulation system, themeasuring of PD has done. PD could begin completely insulation failure (breakdown. Therefore, it is veryimportant to understand the characteristic of PD and the enclose event on it, because PD is a main factorwhich caused insulation failure.This paper presents the result of PD measurement in the laboratory that used needle-plane electrode. Itwas supported by equipments such as osiloskop Digital GDS 2104 GW Instek, HPF, and RC detector.Polymer sample that used in this research is LLDPE (Linier Low Density Polyethylene and HDPE with 20x 4 x 25 mm3 dimension in each. Needle was made by steel (length 50 mm and diameter 1.15 mm, it wasstick to the polymer material. The distance between needle to the plane is 5 mm. The applied voltage foreach sample was 16 kVrms, 18 kVrms, 20 kVrms and 22 kVrms. The Taking of PD data was done in thefirst minute, 10th minute, 20th and so on until 180th minute.The measurement result shows that the characteristic of PD number and maximum charge as a function oftime and as a function of applied voltage inclined increasing both on LLDPE and HDPE. But, PD intensityin HDPE is higher than LLDPE.

  3. Partial Discharge Phase Distribution Of Palm Oil As Insulating Liquid

    Directory of Open Access Journals (Sweden)

    Abdul Rajab

    2011-04-01

    Full Text Available Due to the low biodegradability level of mineral oil and its susceptibility to the fire, palm oil was proposed as alternative insulating liquid. This paper discusses partial discharge (PD in palm oil under sinusoidal voltages and the comparison with mineral oil. PD was generated using a needle-plane electrode configuration which is enable enhancing electric field at the needle tip. PD pulses were detected using RC detector and they were measured using a Computer-based partial discharge measurement system. The results showed that PD activities in both oils are similar. The PD was initiated at the negative polarity of applied voltage. The discharges took place in both polarity’s of applied voltage with PD number was higher at negative one. Several discharges phenomena showed the presence of space charge which changed electric field and governed PD activities besides the main field introduced by voltage application.

  4. A Modular Approach for Teaching Partial Discharge Phenomenon through Experiment

    Science.gov (United States)

    Chatterjee, B.; Dey, D.; Chakravorti, S.

    2011-01-01

    Partial discharge (PD) monitoring is an effective predictive maintenance tool for electrical power equipment. As a result, an understanding of the theory related to PD and the associated measurement techniques is now necessary knowledge for power engineers in their professional life. This paper presents a modular course on PD phenomenon in which…

  5. Computer-based instrumentation for partial discharge detection in GIS

    International Nuclear Information System (INIS)

    Md Enamul Haque; Ahmad Darus; Yaacob, M.M.; Halil Hussain; Feroz Ahmed

    2000-01-01

    Partial discharge is one of the prominent indicators of defects and insulation degradation in a Gas Insulated Switchgear (GIS). Partial discharges (PD) have a harmful effect on the life of insulation of high voltage equipment. The PD detection using acoustic technique and subsequent analysis is currently an efficient method of performing non-destructive testing of GIS apparatus. A low cost PC-based acoustic PD detection instrument has been developed for the non-destructive diagnosis of GIS. This paper describes the development of a PC-based instrumentation system for partial discharge detection in GIS and some experimental results have also presented. (Author)

  6. Partial discharge characteristics and mechanism in voids at impulse voltages

    International Nuclear Information System (INIS)

    Zhao, X F; Guo, Z F; Wang, Y Y; Li, J H; Li, Y M; Yao, X

    2011-01-01

    Partial discharge (PD) characteristics and mechanism in artificial cavities in an epoxy plate have been investigated for different void dimensions and impulse voltage waveforms. A differential measurement system was developed in order to detect PD current pulses effectively. Experimental results showed that the 50% probability PD inception voltage (PDIV 50 ) increases initially as the cavity diameter decreases at constant depth for double exponential impulses as well as oscillating impulses, but after aging, it becomes independent of the cavity diameter. Moreover, some distinctive characteristics of PD (e.g. main discharge and reverse discharge during the rise and fall phases of the applied voltage) were also investigated. The differences of the PD propagation and the mechanism between double exponential impulses and oscillating impulse were discussed

  7. Propagation of Partial Discharge and Noise Pulses in Turbine Generators

    DEFF Research Database (Denmark)

    Henriksen, Mogens; Stone, G. C.; Kurtz, M.

    1986-01-01

    Changes with time in the partial discharge (PD) activity originating in a generator stator's insulation system provide information about the electrical integrity of the stator winding. It is desirable to measure PD during normal service to minimize costs. To do this successfully, the influence...... of electrical interference must be reduced. Tests are reported which characterize the nature of discharge and noise pulses when using capacitive couplers mounted on each of the phase leads and an RF current transformer mounted on the neutral lead for signal detection. Significant differences between PD...... and electrical noise have been observed....

  8. SVM-based Partial Discharge Pattern Classification for GIS

    Science.gov (United States)

    Ling, Yin; Bai, Demeng; Wang, Menglin; Gong, Xiaojin; Gu, Chao

    2018-01-01

    Partial discharges (PD) occur when there are localized dielectric breakdowns in small regions of gas insulated substations (GIS). It is of high importance to recognize the PD patterns, through which we can diagnose the defects caused by different sources so that predictive maintenance can be conducted to prevent from unplanned power outage. In this paper, we propose an approach to perform partial discharge pattern classification. It first recovers the PRPD matrices from the PRPD2D images; then statistical features are extracted from the recovered PRPD matrix and fed into SVM for classification. Experiments conducted on a dataset containing thousands of images demonstrates the high effectiveness of the method.

  9. A Review of Online Partial Discharge Measurement of Large Generators

    Directory of Open Access Journals (Sweden)

    Yuanlin Luo

    2017-10-01

    Full Text Available Online partial discharge (PD measurements have long been used as an effective means to assess the condition of the stator windings of large generators. An increase in the use of PD online measurement systems during the last decade is evident. Improvements in the detection capabilities are partly the reason for the increased popularity. Another reason has been the development of digital signal processing techniques. In addition, rapid progress is being made in automated single PD source classification. However, there are still some factors hindering wider application of the system, such as the complex PD mechanism and PD pulse propagation in stator windings, the presence of detrimental noise and disturbances on-site, and multiple PD sources occurring simultaneously. To avoid repetition of past work and to provide an overview for fresh researchers in this area, this paper presents a comprehensive survey of the state-of-the-art knowledge on PD mechanism, PD pulse propagation in stator windings, PD signal detection methods and signal processing techniques. Areas for further research are also presented.

  10. Development of Partial Discharging Simulation Test Equipment

    Science.gov (United States)

    Kai, Xue; Genghua, Liu; Yan, Jia; Ziqi, Chai; Jian, Lu

    2017-12-01

    In the case of partial discharge training for recruits who lack of on-site work experience, the risk of physical shock and damage of the test equipment may be due to the limited skill level and improper operation by new recruits. Partial discharge simulation tester is the use of simulation technology to achieve partial discharge test process simulation, relatively true reproduction of the local discharge process and results, so that the operator in the classroom will be able to get familiar with and understand the use of the test process and equipment.The teacher sets up the instrument to display different partial discharge waveforms so that the trainees can analyze the test results of different partial discharge types.

  11. Partial discharge as a stator winding evaluation tool

    International Nuclear Information System (INIS)

    Maughan, C.V.

    2005-01-01

    This paper has been prepared to illustrate the value of partial discharge (PD) testing in assessing the condition of stator windings on operating generators and motors. The database of one particular PD system vendor was chosen for this study because of the magnitude of data accumulated by this company over the last 15 years. It was felt that sufficient data had been accumulated to allow useful statistical analysis of the capabilities of PD testing. The PD detection technology used by Iris has been installed on about 6000 generators and motors, and has inspection information from about 3600 machines. On these 3600 generators and motors, PD has successfully identified 209 potential problems that were verified by inspection to be present. In most cases, moderate corrective maintenance permitted return of the equipment to service without major repairs. An estimate of the actual number of avoided failures was not possible from the available reports. But it is clear that many potentially serious stator winding failures were avoided as a result of removal of these machines from service because of high PD readings. No attempt has been made in the paper to provide technical background or details of the PD test/analysis processes. There are numerous technical papers and industry guides; the interested reader is referred to IEEE 1434, EPRI Reports, and other documents in the Bibliography. While this paper is based somewhat narrowly on data from only one company, there are several other companies involved in PD testing and evaluation. As described below in this paper, these companies have also been successful in identifying stator winding problems through the use of PD equipment. Clearly, PD testing is a useful tool in monitoring and assessing the condition of stator windings, as well as other associated electrical equipment in the power plant. Because of the power of PD testing, it is expected that the use of PD monitoring will continue to expand at a significant rate in

  12. Partial discharges and bulk dielectric field enhancement

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Johansson, Torben

    2000-01-01

    A consequence of partial discharge activity within a gaseous void is the production of a field enhancement in the solid dielectric in the proximity of the void. This situation arises due to the charge created by the partial discharges accumulating at the void wall. The influence of the spatial...

  13. Partial Discharge Tests using the Cigré II method

    DEFF Research Database (Denmark)

    Casale, M. Di Lorenzo del; Schifani, R.; Holbøll, Joachim

    2000-01-01

    In this paper, the results of an experimental project on insulating material aging, performed in both Denmark and Italy, are reported. This study was concerned with partial discharge (PD) behavior at temperatures between 30 and 80°C using CIGRE method II. The material tested was a commercial...... polymethylmethacrylate (PMMA) which was chosen not for its good dielectric properties but rather because much of its discharge resistance data at ambient temperature is already well documented. A description is given of the theoretical and experimental methodology followed in this work. Mixed Weibull analysis techniques...... in terms of the PD amplitude and phase distribution characteristics were employed to distinguish the presence of different aging mechanisms. Such a difference was observed at 30 and at 80°C. At 30°C the analysis inferred a single discharge aging process acting until breakdown, while at 80°C the results...

  14. Partial discharge testing of in-situ power cable accessories

    Energy Technology Data Exchange (ETDEWEB)

    Orban, H. E.

    2002-07-01

    An overview of commercially available diagnostic methods for in-situ power cable accessories is given and relevant field experiences with these diagnostics are described. The discussion includes both PILC and polymeric insulated cables. Two major types of degradation are most frequently involved in cable systems. One is an overall condition caused by chemical aging and /or water treeing. Diagnostics for this type of aging include dissipation factor (loss angle), harmonic analysis, return voltage, isothermal relaxation current, dielectric response, or dc leakage current. The second type of degradation is discrete or incremental; condition assessment utilizes dissipation factor measurements or partial discharge (PD) level measurements. The focus in this paper is on PD diagnostics, especially off-line methods such as the 60 Hz test, the combined AC and VLF diagnostic, and the oscillating wave test system test. Among on-line diagnostics, ultrasonic detection of partial discharge and measurement of partial discharge by installing direct, capacitive or inductive couplers near cable accessories, are described. Overall, partial discharge detection and location in cable accessories is considered inadequate, since interpretation of results is difficult due to the number of variables involved. 28 refs., 1 tab.

  15. Partial discharges within two spherical voids in an epoxy resin

    International Nuclear Information System (INIS)

    Illias, H A; Mokhlis, H; Tunio, M A; Chen, G; Bakar, A H A

    2013-01-01

    A void in a dielectric insulation material may exist due to imperfection in the insulation manufacturing or long term stressing. Voids have been identified as one of the common sources of partial discharge (PD) activity within an insulation system, such as in cable insulation and power transformers. Therefore, it is important to study PD phenomenon within void cavities in insulation. In this work, a model of PD activity within two spherical voids in a homogeneous dielectric material has been developed using finite element analysis software to study the parameters affecting PD behaviour. The parameters that have been taken into account are the void surface conductivity, electron generation rate and the inception and extinction fields. Measurements of PD activity within two spherical voids in an epoxy resin under ac sinusoidal applied voltage have also been performed. The simulation results have been compared with the measurement data to validate the model and to identify the parameters affecting PD behaviour. Comparison between measurements of PD activity within single and two voids in a dielectric material have also been made to observe the difference of the results under both conditions. (paper)

  16. Partial discharge transients: The field theoretical approach

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Crichton, George C

    1998-01-01

    Up until the mid-1980s the theory of partial discharge transients was essentially static. This situation had arisen because of the fixation with the concept of void capacitance and the use of circuit theory to address what is in essence a field problem. Pedersen rejected this approach and instead...... began to apply field theory to the problem of partial discharge transients. In the present paper, the contributions of Pedersen using the field theoretical approach will be reviewed and discussed....

  17. Online partial discharges localization system

    Directory of Open Access Journals (Sweden)

    Primo Alberto Calva Chavarria

    2013-01-01

    Full Text Available En este artículo se presentan el diseño y construcción de un sistema no invasivo de localización de descargas parciales (PD's en línea; el cual consiste básicamente de cuatro antenas iguales tipo discono con un ancho de banda de 30 MHz a 1.2 GHZ y una frecuencia central de 615 MHz, conectada a un registrador digital de alta velocidad y cuatro canales; las señales electromagnéticas obtenidas se procesan en una computadora portátil empleando la Transformada Wavelet y la Transformada Rápida de Fourier (FFT para la discriminación del ruido electromagnético y la identificación de la fuente de origen de las descargas parciales (DPs respectivamente, adicionalmente se emplea un método esférico de localización espacial en R3. Se reportan mediciones obtenidas en un laboratorio de alta tensión y en campo.

  18. Towards Optical Partial Discharge Detection with Micro Silicon Photomultipliers

    Directory of Open Access Journals (Sweden)

    Ming Ren

    2017-11-01

    Full Text Available Optical detection is reliable in intrinsically characterizing partial discharges (PDs. Because of the great volume and high-level power supply of the optical devices that can satisfy the requirements in photosensitivity, optical PD detection can merely be used in laboratory studies. To promote the practical application of the optical approach in an actual power apparatus, a silicon photomultiplier (SiPM-based PD sensor is introduced in this paper, and its basic properties, which include the sensitivity, pulse resolution, correlation with PD severity, and electromagnetic (EM interference immunity, are experimentally evaluated. The stochastic phase-resolved PD pattern (PRPD for three typical insulation defects are obtained by SiPM PD detector and are compared with those obtained using a high-frequency current transformer (HFCT and a vacuum photomultiplier tube (PMT. Because of its good performances in the above aspects and its additional advantages, such as the small size, low power supply, and low cost, SiPM offers great potential in practical optical PD monitoring.

  19. A novel technique for partial discharge measurement

    International Nuclear Information System (INIS)

    Farrokh, Fattahi; Navid, Tagizadegan; Ahmad, Zentabchi; Mehdi, Rashidi

    2005-01-01

    Full text : Partial discharges are a sensitive measure of local electrical stress and therefore the measurements is very often used as a quality check of the insulation. The inception of partial discharges gives information on the limit of the electrical strength of the insulating material before a complete discharge between the conductors takes place. Therefore the insulating material can be tested with high stress but without damaging or reducing the performance of the insulation. Also, for partial discharge measurements it should be taken into account that every stress of the insulation will have an influence on the life expectancy of the material, but a reasonable compromise between the stress during the measurement in order to get reliable results and the influence of he lifetime should be found and established in the relevant standard for the particular equipment, for example transformers, cables and so on

  20. Influence of bulk dielectric polarization upon partial discharge transients effect of heterogeneous dielectric geometry

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Crichton, George C.

    2000-01-01

    A physically valid theory of partial discharge (PD) transients is based upon the concept of the charge induced upon the detecting electrode by the PD. This induced charge consists of two components. One is associated with the actual space charge in the void, while the other is related to changes...

  1. Partial discharges in ellipsoidal and spheroidal voids

    DEFF Research Database (Denmark)

    Crichton, George C; Karlsson, P. W.; Pedersen, Aage

    1989-01-01

    Transients associated with partial discharges in voids can be described in terms of the charges induced on the terminal electrodes of the system. The relationship between the induced charge and the properties which are usually measured is discussed. The method is illustrated by applying it to a s......Transients associated with partial discharges in voids can be described in terms of the charges induced on the terminal electrodes of the system. The relationship between the induced charge and the properties which are usually measured is discussed. The method is illustrated by applying...

  2. Partial discharges in spheroidal voids: Void orientation

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson

    1997-01-01

    Partial discharge transients can be described in terms of the charge induced on the detecting electrode. The influence of the void parameters upon the induced charge is examined and discussed for spheroidal voids. It is shown that a quantitative interpretation of the induced charge requires...

  3. Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated Switchgears

    Directory of Open Access Journals (Sweden)

    Guoming Wang

    2017-11-01

    Full Text Available With the increasing demand for precise condition monitoring and diagnosis of gas-insulated switchgears (GISs, it has become a challenge to improve the detection sensitivity of partial discharge (PD induced in the GIS spacer. This paper deals with the elimination of the capacitive component from the phase-resolved partial discharge (PRPD signal generated in GIS spacers based on discrete wavelet transform (WT. Three types of typical insulation defects were simulated using PD cells. The single PD pulses were detected and were further used to determine the optimal mother wavelet. As a result, the bior6.8 was selected to decompose the PD signal into 8 levels and the signal energy at each level was calculated. The decomposed components related with capacitive disturbance were discarded, whereas those associated with PD were de-noised by a threshold and a thresholding function. Finally, the PRPD signals were reconstructed using the de-noised components.

  4. Critical analysis of partial discharge dynamics in air filled spherical voids

    Science.gov (United States)

    Callender, G.; Golosnoy, I. O.; Rapisarda, P.; Lewin, P. L.

    2018-03-01

    In this paper partial discharge (PD) is investigated inside a spherical air filled void at atmospheric pressure using a drift diffusion model. Discharge dynamics consisted of an electron avalanche transitioning into positive streamer, in agreement with earlier work on dielectric barrier discharges. Different model configurations were utilised to test many of the concepts employed in semi-analytical PD activity models, which use simplistic descriptions of the discharge dynamics. The results showed that many of these concepts may be erroneous, with significant discrepancies between the canonical reasoning and the simulation results. For example, the residual electric field, the electric field after a discharge, is significantly lower than the estimates used by classical PD activity models in the literature.

  5. Analysis of Insulating Material of XLPE Cables considering Innovative Patterns of Partial Discharges

    Directory of Open Access Journals (Sweden)

    Fernando Figueroa Godoy

    2017-01-01

    Full Text Available This paper aims to analyze the quality of insulation in high voltage underground cables XLPE using a prototype which classifies the following usual types of patterns of partial discharge (PD: (1 internal PD, (2 superficial PD, (3 corona discharge in air, and (4 corona discharge in oil, in addition to considering two new PD patterns: (1 false contact and (2 floating ground. The tests and measurements to obtain the patterns and study cases of partial discharges were performed at the Testing Laboratory Equipment and Materials (LEPEM of the Federal Electricity Commission of Mexico (CFE using a measuring equipment LDIC and norm IEC60270. To classify the six patterns of partial discharges mentioned above a Probabilistic Neural Network Bayesian Modified (PNNBM method having the feature of using a large amount of data will be used and it is not saturated. In addition, PNN converges, always finding a solution in a short period of time with low computational cost. The insulation of two high voltage cables with different characteristics was analyzed. The test results allow us to conclude which wire has better insulation.

  6. Technical advancements in the integration of online partial discharge monitoring in distribution cable networks

    NARCIS (Netherlands)

    Wagenaars, P.; Wouters, P.A.A.F.; Wielen, van der P.C.J.M.; Steennis, F.

    2009-01-01

    Online partial discharge (PD) detection and location systems for medium-voltage (MV) cables have been developed over the past years and are currently introduced by utilities on an increasingly large scale. This paper addresses a few of the new challenges related to the integration of these systems

  7. Online calibration of high-frequency partial discharge signals in three-phase belted power cables

    NARCIS (Netherlands)

    Wouters, P.A.A.F.

    2005-01-01

    Partial discharge (PD) magnitudes from classical detection techniques are expressed in terms of apparent charges. Signals from HF/VHF/UHF techniques on substation components are often hard to express in this quantity because of complex signal excitation and propagation channels. A method to

  8. Optical fiber sensor of partial discharges in High Voltage DC experiments

    Science.gov (United States)

    Búa-Núñez, I.; Azcárraga-Ramos, C. G.; Posada-Román, J. E.; Garcia-Souto, J. A.

    2014-05-01

    A setup simulating High Voltage DC (HVDC) transformers barriers was developed to demonstrate the effectiveness of an optical fiber (OF) sensor in detecting partial discharges (PD) under these peculiar conditions. Different PD detection techniques were compared: electrical methods, and acoustic methods. Standard piezoelectric sensors (R15i-AST) and the above mentioned OF sensors were used for acoustic detection. The OF sensor was able to detect PD acoustically with a sensitivity better than the other detection methods. The multichannel instrumentation system was tested in real HVDC conditions with the aim of analyzing the behavior of the insulation (mineral oil/pressboard).

  9. Design parameter based method of partial discharge detection and location in power transformers

    Directory of Open Access Journals (Sweden)

    Kumar Santosh Annadurai

    2009-01-01

    Full Text Available Insulation defect detection in time ensures higher operational reliability of power system assets. Power transformers are the most critical unit of power systems both from economical and operational front. Hence it becomes necessary to have knowledge of the actual insulation condition of transformer to increase dependability of the system. The performance and ageing of the transformer insulation is mainly affected by Partial discharges (PD. Proper diagnosis in terms of amplitude and location of partial discharge in a power transformer enables us to predict well in advance, with much confidence, the defect in insulation system, which avoids large catastrophic failures. In this work a 20kVA, 230/50kV single phase core type transformer is used for evaluation of the transfer function-based partial discharge detection and location using modeling of the winding, using design data. The simulation of capturing on-line PD pulses across the bushing tap capacitor is done for various tap positions. Standard PD source model is used to inject PD pulse signal at 10 tap locations in the winding and corresponding response signatures are captured at the bushing tap end (across 1000pF. The equivalent high frequency model of the winding is derived from the design parameters using analytical calculations and simulations in packages such as MAGNET and ANSOFT. The test conditions are simulated using ORCAD-9 and the results are evaluated for location accuracy using design parameter based PD monitoring method. .

  10. Measurement of partial discharge inception characteristics in sub-cooled liquid nitrogen

    International Nuclear Information System (INIS)

    Koo, J.Y.; Lee, S.H.; Shin, W.J.; Khan, Umer A.; Oh, S.H.; Seong, J.K.; Lee, B.W.

    2011-01-01

    We measured partial discharge and partial discharge initiation voltage of subcooled liquid nitrogen. Various kinds of test samples have been prepared. Sub-cooled temperature in liquid nitrogen were changed. The number of PD pluses were decreased when 68 K liquid nitrogen was used. Sub-cooled liquid nitrogen has positive effects to suppress PD activities. Partial discharge (PD) measurement is one of the effective diagnostic techniques to predict abnormal high voltage dielectric insulation conditions of the electric equipments. PD diagnostic techniques were also could be utilized to evaluate the conditions of cryogenic dielectric insulation media of high temperature superconducting electric equipment in liquid nitrogen. Generally, liquid nitrogen at 77 K is used as cryogenic and dielectric media for high temperature superconducting devices for high voltage electric power systems. But due to generation of bubbles during quench conditions which cause harmful effect on the properties of liquid nitrogen insulation, sub-cooled nitrogen under 77 K was also employed to suppress bubble formation. In this work, investigation of PD characteristics of sub-cooled liquid nitrogen was conducted in order to clarify the relation between PD inception and the temperature of liquid nitrogen. It was observed that measured PDIV (PD inception voltage) shows little differences according to the sub-cooled temperature of liquid nitrogen, but the magnitude and total numbers of PD has been slightly decreased according the decrease of cooled temperature of liquid nitrogen. From experimental results, it was deduced that the sub-cooled liquid nitrogen from 68 K to 77 K, could be applicable without any considerations of the variation of PDIV.

  11. Inductive Sensor Performance in Partial Discharges and Noise Separation by Means of Spectral Power Ratios

    Directory of Open Access Journals (Sweden)

    Jorge Alfredo Ardila-Rey

    2014-02-01

    Full Text Available Partial discharge (PD detection is a standardized technique to qualify electrical insulation in machines and power cables. Several techniques that analyze the waveform of the pulses have been proposed to discriminate noise from PD activity. Among them, spectral power ratio representation shows great flexibility in the separation of the sources of PD. Mapping spectral power ratios in two-dimensional plots leads to clusters of points which group pulses with similar characteristics. The position in the map depends on the nature of the partial discharge, the setup and the frequency response of the sensors. If these clusters are clearly separated, the subsequent task of identifying the source of the discharge is straightforward so the distance between clusters can be a figure of merit to suggest the best option for PD recognition. In this paper, two inductive sensors with different frequency responses to pulsed signals, a high frequency current transformer and an inductive loop sensor, are analyzed to test their performance in detecting and separating the sources of partial discharges.

  12. Artificial Neural Network Application for Partial Discharge Recognition: Survey and Future Directions

    Directory of Open Access Journals (Sweden)

    Abdullahi Abubakar Mas’ud

    2016-07-01

    Full Text Available In order to investigate how artificial neural networks (ANNs have been applied for partial discharge (PD pattern recognition, this paper reviews recent progress made on ANN development for PD classification by a literature survey. Contributions from several authors have been presented and discussed. High recognition rate has been recorded for several PD faults, but there are still many factors that hinder correct recognition of PD by the ANN, such as high-amplitude noise or wide spectral content typical from industrial environments, trial and error approaches in determining an optimum ANN, multiple PD sources acting simultaneously, lack of comprehensive and up to date databank of PD faults, and the appropriate selection of the characteristics that allow a correct recognition of the type of source which are currently being addressed by researchers. Several suggestions for improvement are proposed by the authors include: (1 determining the optimum weights in training the ANN; (2 using PD data captured over long stressing period in training the ANN; (3 ANN recognizing different PD degradation levels; (4 using the same resolution sizes of the PD patterns when training and testing the ANN with different PD dataset; (5 understanding the characteristics of multiple concurrent PD faults and effectively recognizing them; and (6 developing techniques in order to shorten the training time for the ANN as applied for PD recognition Finally, this paper critically assesses the suitability of ANNs for both online and offline PD detections outlining the advantages to the practitioners in the field. It is possible for the ANNs to determine the stage of degradation of the PD, thereby giving an indication of the seriousness of the fault.

  13. Influence of Nanosilica Filler Content in LDPE Composites on Partial Discharge Characteristics

    Institute of Scientific and Technical Information of China (English)

    Z. Abdul-Malek; A.M. Azzin; Y.Z. Ariel; Aulia; K.Y. Lau; M. Jaafar

    2011-01-01

    Partial discharges (PDs) due to artificial void in samples of LDPE nanocomposite sheet have been investiga- ted in this work. PDs may cause the degradation of insulating materials and may affect the lifetime of high-voltage ap- paratus. An experimental work using sphere ball-plane electrode system (CIGRE Method II) and a 1.0 mm LDPE composite sheet was carried out. Different weight percentages of nanosilica (0%, 2%, 4%, 6% and 8%) were used. PD experimental results, such as PD magnitude and PD number (both PD pulse polarities), as functions of the ap- plied stress duration at a specified applied voltage were compared. The surface morphology of specimens was also presented and this conforms to the PD findings. The experimental results show that the PD characteristics of the LDPE generally improve with the introduction of nanosilica, the composite with the highest content of filler, namely the 8% (wt) nanosilica sample has the least partial discharge activities.

  14. Partial discharge early-warning through ultraviolet spectroscopic detection of SO2

    International Nuclear Information System (INIS)

    Zhao, Yu; Wang, Xianpei; Dai, Dangdang; Dong, Zhengcheng; Huang, Yunguang

    2014-01-01

    Surveillance of SF 6  decomposition products is significant for detection of partial discharge (PD) in gas insulation switchgear (GIS). As a basis in on-site detection and diagnosis, PD early-warning aims to quickly find the abnormalities using a simple and cheap device. In this paper, SO 2  is chosen as a feature product and detected through ultraviolet spectroscopy. The derivative method is employed for baseline correction and spectral enhancement. The standard gases of the main decomposition products are qualitatively and quantitatively detected. Then decomposition experiments with different defects are designed to further verify the feasibility. As a stable decomposition product under PD, SO 2  is proved to be applicable for PD early-warning in the field. By selecting the appropriate wavelength range, namely 290–310 nm, ultraviolet derivative spectroscopy is sensitive enough to the trace SO 2  in the decomposed gas and the interference of other products can be avoided. Fast Fourier transform could be used for feature extraction in qualitative detection. Concentrations of SO 2  and other by-products increase with increasing discharge time and could be affected by the discharge energy and PD type. Ultraviolet detection based on SO 2  is effective for PD early-warning but the threshold should still be carefully selected in practice. (paper)

  15. A Comparison of Inductive Sensors in the Characterization of Partial Discharges and Electrical Noise Using the Chromatic Technique

    Directory of Open Access Journals (Sweden)

    Jorge Alfredo Ardila-Rey

    2018-03-01

    Full Text Available Partial discharges (PDs are one of the most important classes of ageing processes that occur within electrical insulation. PD detection is a standardized technique to qualify the state of the insulation in electric assets such as machines and power cables. Generally, the classical phase-resolved partial discharge (PRPD patterns are used to perform the identification of the type of PD source when they are related to a specific degradation process and when the electrical noise level is low compared to the magnitudes of the PD signals. However, in practical applications such as measurements carried out in the field or in industrial environments, several PD sources and large noise signals are usually present simultaneously. In this study, three different inductive sensors have been used to evaluate and compare their performance in the detection and separation of multiple PD sources by applying the chromatic technique to each of the measured signals.

  16. A Comparison of Inductive Sensors in the Characterization of Partial Discharges and Electrical Noise Using the Chromatic Technique.

    Science.gov (United States)

    Ardila-Rey, Jorge Alfredo; Montaña, Johny; de Castro, Bruno Albuquerque; Schurch, Roger; Covolan Ulson, José Alfredo; Muhammad-Sukki, Firdaus; Bani, Nurul Aini

    2018-03-29

    Partial discharges (PDs) are one of the most important classes of ageing processes that occur within electrical insulation. PD detection is a standardized technique to qualify the state of the insulation in electric assets such as machines and power cables. Generally, the classical phase-resolved partial discharge (PRPD) patterns are used to perform the identification of the type of PD source when they are related to a specific degradation process and when the electrical noise level is low compared to the magnitudes of the PD signals. However, in practical applications such as measurements carried out in the field or in industrial environments, several PD sources and large noise signals are usually present simultaneously. In this study, three different inductive sensors have been used to evaluate and compare their performance in the detection and separation of multiple PD sources by applying the chromatic technique to each of the measured signals.

  17. Ultrasonic partial discharge monitoring method on instrument transformers

    Directory of Open Access Journals (Sweden)

    Kartalović Nenad

    2012-01-01

    Full Text Available Sonic and ultrasonic partial discharge monitoring have been applied since the early days of these phenomena monitoring. Modern measurement and partial discharge acoustic (ultrasonic and sonic monitoring method has been rapidly evolving as a result of new electronic component design, information technology and updated software solutions as well as the development of knowledge in the partial discharge diagnosis. Electrical discharges in the insulation system generate voltage-current pulses in the network and ultrasonic waves that propagate through the insulation system and structure. Amplitude-phase-frequency analysis of these signals reveals information about the intensity, type and location of partial discharges. The paper discusses the possibility of ultrasonic method selectivity improvement and the increase of diagnosis reliability in the field. Measurements were performed in the laboratory and in the field while a number of transformers were analysed for dissolved gases in the oil. A comparative review of methods for the partial discharge detection is also presented in this paper.

  18. Partial discharge transients and the influence of dielectric polarization

    DEFF Research Database (Denmark)

    Pedersen, A.; Crichton, George C; McAllister, Iain Wilson

    1996-01-01

    Based on a field-theoretical approach, a physically valid theory of partial discharge transients has been developed. The theory is based upon the concept of the charge induced upon the detecting electrode by the partial discharge. This induced charge is shown to be composed of a component...

  19. The theory and measurement of partial discharge transients

    DEFF Research Database (Denmark)

    Pedersen, Aage; Crichton, George C; McAllister, Iain Wilson

    1991-01-01

    A theoretical approach to partial discharge transients is presented. This approach is based on the relationship between the charge induced on the measurement electrode by those created in the interelectrode volume during partial discharge activity. The primary sources for these induced charges ar...... electrode systems of practical interest is illustrated. A discussion of the salient features and practical aspects of the theory is included...

  20. The influence of spherical cavity surface charge distribution on the sequence of partial discharge events

    International Nuclear Information System (INIS)

    Illias, Hazlee A; Chen, George; Lewin, Paul L

    2011-01-01

    In this work, a model representing partial discharge (PD) behaviour of a spherical cavity within a homogeneous dielectric material has been developed to study the influence of cavity surface charge distribution on the electric field distribution in both the cavity and the material itself. The charge accumulation on the cavity surface after a PD event and charge movement along the cavity wall under the influence of electric field magnitude and direction has been found to affect the electric field distribution in the whole cavity and in the material. This in turn affects the likelihood of any subsequent PD activity in the cavity and the whole sequence of PD events. The model parameters influencing cavity surface charge distribution can be readily identified; they are the cavity surface conductivity, the inception field and the extinction field. Comparison of measurement and simulation results has been undertaken to validate the model.

  1. The influence of spherical cavity surface charge distribution on the sequence of partial discharge events

    Energy Technology Data Exchange (ETDEWEB)

    Illias, Hazlee A [Department of Electrical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia); Chen, George; Lewin, Paul L, E-mail: h.illias@um.edu.my [Tony Davies High Voltage Laboratory, School of Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ (United Kingdom)

    2011-06-22

    In this work, a model representing partial discharge (PD) behaviour of a spherical cavity within a homogeneous dielectric material has been developed to study the influence of cavity surface charge distribution on the electric field distribution in both the cavity and the material itself. The charge accumulation on the cavity surface after a PD event and charge movement along the cavity wall under the influence of electric field magnitude and direction has been found to affect the electric field distribution in the whole cavity and in the material. This in turn affects the likelihood of any subsequent PD activity in the cavity and the whole sequence of PD events. The model parameters influencing cavity surface charge distribution can be readily identified; they are the cavity surface conductivity, the inception field and the extinction field. Comparison of measurement and simulation results has been undertaken to validate the model.

  2. Partial discharge signal denoising with spatially adaptive wavelet thresholding and support vector machines

    Energy Technology Data Exchange (ETDEWEB)

    Mota, Hilton de Oliveira; Rocha, Leonardo Chaves Dutra da [Department of Computer Science, Federal University of Sao Joao del-Rei, Visconde do Rio Branco Ave., Colonia do Bengo, Sao Joao del-Rei, MG, 36301-360 (Brazil); Salles, Thiago Cunha de Moura [Department of Computer Science, Federal University of Minas Gerais, 6627 Antonio Carlos Ave., Pampulha, Belo Horizonte, MG, 31270-901 (Brazil); Vasconcelos, Flavio Henrique [Department of Electrical Engineering, Federal University of Minas Gerais, 6627 Antonio Carlos Ave., Pampulha, Belo Horizonte, MG, 31270-901 (Brazil)

    2011-02-15

    In this paper an improved method to denoise partial discharge (PD) signals is presented. The method is based on the wavelet transform (WT) and support vector machines (SVM) and is distinct from other WT-based denoising strategies in the sense that it exploits the high spatial correlations presented by PD wavelet decompositions as a way to identify and select the relevant coefficients. PD spatial correlations are characterized by WT modulus maxima propagation along decomposition levels (scales), which are a strong indicative of the their time-of-occurrence. Denoising is performed by identification and separation of PD-related maxima lines by an SVM pattern classifier. The results obtained confirm that this method has superior denoising capabilities when compared to other WT-based methods found in the literature for the processing of Gaussian and discrete spectral interferences. Moreover, its greatest advantages become clear when the interference has a pulsating or localized shape, situation in which traditional methods usually fail. (author)

  3. Study and optimization of the partial discharges in capacitor model ...

    African Journals Online (AJOL)

    that the main cause of failure of these devices is the appearance of partial discharges initiated on edges of armatures. These devices can quickly slam if discharges occur continuously during the liquid impregnation. One of the criteria for selecting impregnating liquids is the behavior of gas bubbles when discharges occur.

  4. Classification of Partial Discharge Measured under Different Levels of Noise Contamination.

    Directory of Open Access Journals (Sweden)

    Wong Jee Keen Raymond

    Full Text Available Cable joint insulation breakdown may cause a huge loss to power companies. Therefore, it is vital to diagnose the insulation quality to detect early signs of insulation failure. It is well known that there is a correlation between Partial discharge (PD and the insulation quality. Although many works have been done on PD pattern recognition, it is usually performed in a noise free environment. Also, works on PD pattern recognition in actual cable joint are less likely to be found in literature. Therefore, in this work, classifications of actual cable joint defect types from partial discharge data contaminated by noise were performed. Five cross-linked polyethylene (XLPE cable joints with artificially created defects were prepared based on the defects commonly encountered on site. Three different types of input feature were extracted from the PD pattern under artificially created noisy environment. These include statistical features, fractal features and principal component analysis (PCA features. These input features were used to train the classifiers to classify each PD defect types. Classifications were performed using three different artificial intelligence classifiers, which include Artificial Neural Networks (ANN, Adaptive Neuro-Fuzzy Inference System (ANFIS and Support Vector Machine (SVM. It was found that the classification accuracy decreases with higher noise level but PCA features used in SVM and ANN showed the strongest tolerance against noise contamination.

  5. An Intelligent Sensor for the Ultra-High-Frequency Partial Discharge Online Monitoring of Power Transformers

    Directory of Open Access Journals (Sweden)

    Jian Li

    2016-05-01

    Full Text Available Ultra-high-frequency (UHF partial discharge (PD online monitoring is an effective way to inspect potential faults and insulation defects in power transformers. The construction of UHF PD online monitoring system is a challenge because of the high-frequency and wide-frequency band of the UHF PD signal. This paper presents a novel, intelligent sensor for UHF PD online monitoring based on a new method, namely a level scanning method. The intelligent sensor can directly acquire the statistical characteristic quantities and is characterized by low cost, few data to output and transmit, Ethernet functionality, and small size for easy installation. The prototype of an intelligent sensor was made. Actual UHF PD experiments with three typical artificial defect models of power transformers were carried out in a laboratory, and the waveform recording method and intelligent sensor proposed were simultaneously used for UHF PD measurement for comparison. The results show that the proposed intelligent sensor is qualified for the UHF PD online monitoring of power transformers. Additionally, three methods to improve the performance of intelligent sensors were proposed according to the principle of the level scanning method.

  6. A lower dimensional feature vector for identification of partial discharges of different origin using time measurements

    International Nuclear Information System (INIS)

    Evagorou, Demetres; Kyprianou, Andreas; Georghiou, George E; Lewin, Paul L; Stavrou, Andreas

    2012-01-01

    Partial discharge (PD) classification into sources of different origin is essential in evaluating the severity of the damage caused by its activity on the insulation of power cables and their accessories. More specifically, some types of PD can be classified as having a detrimental effect on the integrity of the insulation while others can be deemed relatively harmless, rendering the correct classification of different PD types of vital importance to electrical utilities. In this work, a feature vector was proposed based on higher order statistics on selected nodes of the wavelet packet transform (WPT) coefficients of time domain measurements, which can compactly represent the characteristics of different PD sources. To assess its performance, experimental data acquired under laboratory conditions for four different PD sources encountered in power systems were used. The two learning machine methods, namely the support vector machine and the probabilistic neural network, employed as the classification algorithms, achieved overall classification rates of around 98%. In comparison, the utilization of the scaled, raw WPT coefficients as a feature vector resulted in classification accuracy of around 99%, but with a significantly higher number of dimensions (1304 to 16), validating the PD identification ability of the proposed feature. Dimensionality reduction becomes a key factor in online, real-time data collection and processing of PD measurements, reducing the classification effort and the data-storage requirements. Therefore, the proposed method can constitute a potential tool for such online measurements, after addressing issues related to on-site measurements such as the rejection of interference. (paper)

  7. Study and optimization of the partial discharges in capacitor model ...

    African Journals Online (AJOL)

    The initial potential as well as the temperature are known to influence the partial discharge ... The development of electrostatic industry has ... the liquid impregnation. One of the ..... the Surface of Corona charged Uniforms layers of HIPS.

  8. Resonant Frequency Calculation and Optimal Design of Peano Fractal Antenna for Partial Discharge Detection

    Directory of Open Access Journals (Sweden)

    Jian Li

    2012-01-01

    Full Text Available Ultra-high-frequency (UHF approaches have caught increasing attention recently and have been considered as a promising technology for online monitoring partial discharge (PD signals. This paper presents a Peano fractal antenna for UHF PD online monitoring of transformer with small size and multiband. The approximate formula for calculating the first resonant frequency of the Peano fractal antenna is presented. The results show that the first resonant frequency of the Peano fractal antenna is smaller than the Hilbert fractal antenna when the outer dimensions are equivalent approximately. The optimal geometric parameters of the antenna were obtained through simulation. Actual PD experiments had been carried out for two typically artificial insulation defect models, while the proposed antenna and the existing Hilbert antenna were both used for the PD measurement. The experimental results show that Peano fractal antenna is qualified for PD online UHF monitoring and a little more suitable than the Hilbert fractal antenna for pattern recognition by analyzing the waveforms of detected UHF PD signals.

  9. Highly Active, Carbon-supported, PdSn Nano-core, Partially ...

    African Journals Online (AJOL)

    Carbon-supported, Pt partially covered, PdSn alloy nanoparticles (Pt-PdSn/C) were synthesized via a metathetical reaction of PdSn alloy nanoparticles, and a platinum precursor. The electrochemical activity was evaluated by methanol oxidation. The Pt-PdSn/C catalysts were characterized by transmission electron ...

  10. Influence of void defects on partial discharge behavior of superconducting busbar insulation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Chunyu; Huang, Xiongyi, E-mail: huangxy@ipp.ac.cn; Lu, Kun; Li, Guoliang; Zhu, Haisheng; Wang, Jun; Wang, Cao; Dai, Zhiheng; Fang, Linlin; Song, Yuntao

    2017-06-15

    Highlights: • PD detection method was used to check the quality of the superconducting busbar insulation. • The samples with different void fraction were manufactured for comparing. • The discharge inception voltage, PRPD pattern was tested and studied for the samples with different void content. • The PD behaviors in oil bath and air condition were compared. - Abstract: For a magnetic confinement fusion device, the superconducting magnets and busbars need to be insulated with one layer of solid insulation to isolate the high voltage potential from the ground. The insulation layer commonly consists of several interleaved layers of epoxy resin-impregnated glass fiber tapes and polyimide films. The traditional electrical inspection methods for such solidified insulation on the magnet and busbar are a DC voltage test or a Paschen test. These tests measure the quality of the insulation based on the value of leakage currents. However, even if there is a larger quantity of high dielectric strength material implemented, if there are some microcavities or delaminations in the insulation system, the leakage current may be limited to microampere levels under testing levels over dozens of kilovolts. Therefore, it is difficult to judge the insulation quality just by the magnitudes of leakage current. Under long-term operation, such imperceptible defects will worsen and finally completely break down the insulation because of partial discharge (PD) incidents. Therefore, a PD detection test is an important complement to the DC voltage and Paschen tests for magnet and busbar insulations in the field of fusion. It is known that the PD detection test is a mature technique in the electric power industry. In this paper, the PD characteristics of samples containing glass fiber-reinforced composite insulations for use with the superconducting busbar were presented and discussed. Various samples with different void contents were prepared and the PD behaviors were tested.

  11. Influence of void defects on partial discharge behavior of superconducting busbar insulation

    International Nuclear Information System (INIS)

    Wang, Chunyu; Huang, Xiongyi; Lu, Kun; Li, Guoliang; Zhu, Haisheng; Wang, Jun; Wang, Cao; Dai, Zhiheng; Fang, Linlin; Song, Yuntao

    2017-01-01

    Highlights: • PD detection method was used to check the quality of the superconducting busbar insulation. • The samples with different void fraction were manufactured for comparing. • The discharge inception voltage, PRPD pattern was tested and studied for the samples with different void content. • The PD behaviors in oil bath and air condition were compared. - Abstract: For a magnetic confinement fusion device, the superconducting magnets and busbars need to be insulated with one layer of solid insulation to isolate the high voltage potential from the ground. The insulation layer commonly consists of several interleaved layers of epoxy resin-impregnated glass fiber tapes and polyimide films. The traditional electrical inspection methods for such solidified insulation on the magnet and busbar are a DC voltage test or a Paschen test. These tests measure the quality of the insulation based on the value of leakage currents. However, even if there is a larger quantity of high dielectric strength material implemented, if there are some microcavities or delaminations in the insulation system, the leakage current may be limited to microampere levels under testing levels over dozens of kilovolts. Therefore, it is difficult to judge the insulation quality just by the magnitudes of leakage current. Under long-term operation, such imperceptible defects will worsen and finally completely break down the insulation because of partial discharge (PD) incidents. Therefore, a PD detection test is an important complement to the DC voltage and Paschen tests for magnet and busbar insulations in the field of fusion. It is known that the PD detection test is a mature technique in the electric power industry. In this paper, the PD characteristics of samples containing glass fiber-reinforced composite insulations for use with the superconducting busbar were presented and discussed. Various samples with different void contents were prepared and the PD behaviors were tested.

  12. Characteristics of Partial Discharge and Ozone Generation for Twisted-pair of Enameled Wires under High-repetitive Impulse Voltage Application

    Science.gov (United States)

    Kanazawa, Seiji; Enokizono, Masato; Shibakita, Toshihide; Umehara, Eiji; Toshimitsu, Jun; Ninomiya, Shinji; Taniguchi, Hideki; Abe, Yukari

    In recent years, inverter drive machines such as a hybrid vehicle and an electric vehicle are operated under high voltage pulse with high repetition rate. In this case, inverter surge is generated and affected the machine operation. Especially, the enameled wire of a motor is deteriorated due to the partial discharge (PD) and finally breakdown of the wire will occur. In order to investigate a PD on a resistant enameled wire, characteristics of PD in the twisted pair sample under bipolar repetitive impulse voltages are investigated experimentally. The relationship between the applied voltage and discharge current was measured at PD inception and extinction, and we estimated the repetitive PD inception and extinction voltages experimentally. The corresponding optical emission of the discharge was also observed by using an ICCD camera. Furthermore, ozone concentration due to the discharge was measured during the life-time test of the resistant enameled wires from a working environmental point of view.

  13. Improving detection sensitivity for partial discharge monitoring of high voltage equipment

    Science.gov (United States)

    Hao, L.; Lewin, P. L.; Swingler, S. G.

    2008-05-01

    Partial discharge (PD) measurements are an important technique for assessing the health of power apparatus. Previous published research by the authors has shown that an electro-optic system can be used for PD measurement of oil-filled power transformers. A PD signal generated within an oil-filled power transformer may reach a winding and then travel along the winding to the bushing core bar. The bushing, acting like a capacitor, can transfer the high frequency components of the partial discharge signal to its earthed tap point. Therefore, an effective PD current measurement can be implemented at the bushing tap by using a radio frequency current transducer around the bushing-tap earth connection. In addition, the use of an optical transmission technique not only improves the electrical noise immunity and provides the possibility of remote measurement but also realizes electrical isolation and enhances safety for operators. However, the bushing core bar can act as an aerial and in addition noise induced by the electro-optic modulation system may influence overall measurement sensitivity. This paper reports on a machine learning technique, namely the use of a support vector machine (SVM), to improve the detection sensitivity of the system. Comparison between the signal extraction performances of a passive hardware filter and the SVM technique has been assessed. The results obtained from the laboratory-based experiment have been analysed and indicate that the SVM approach provides better performance than the passive hardware filter and it can reliably detect discharge signals with apparent charge greater than 30 pC.

  14. Improving detection sensitivity for partial discharge monitoring of high voltage equipment

    International Nuclear Information System (INIS)

    Hao, L; Lewin, P L; Swingler, S G

    2008-01-01

    Partial discharge (PD) measurements are an important technique for assessing the health of power apparatus. Previous published research by the authors has shown that an electro-optic system can be used for PD measurement of oil-filled power transformers. A PD signal generated within an oil-filled power transformer may reach a winding and then travel along the winding to the bushing core bar. The bushing, acting like a capacitor, can transfer the high frequency components of the partial discharge signal to its earthed tap point. Therefore, an effective PD current measurement can be implemented at the bushing tap by using a radio frequency current transducer around the bushing-tap earth connection. In addition, the use of an optical transmission technique not only improves the electrical noise immunity and provides the possibility of remote measurement but also realizes electrical isolation and enhances safety for operators. However, the bushing core bar can act as an aerial and in addition noise induced by the electro-optic modulation system may influence overall measurement sensitivity. This paper reports on a machine learning technique, namely the use of a support vector machine (SVM), to improve the detection sensitivity of the system. Comparison between the signal extraction performances of a passive hardware filter and the SVM technique has been assessed. The results obtained from the laboratory-based experiment have been analysed and indicate that the SVM approach provides better performance than the passive hardware filter and it can reliably detect discharge signals with apparent charge greater than 30 pC

  15. Use of ultrasonic array method for positioning multiple partial discharge sources in transformer oil.

    Science.gov (United States)

    Xie, Qing; Tao, Junhan; Wang, Yongqiang; Geng, Jianghai; Cheng, Shuyi; Lü, Fangcheng

    2014-08-01

    Fast and accurate positioning of partial discharge (PD) sources in transformer oil is very important for the safe, stable operation of power systems because it allows timely elimination of insulation faults. There is usually more than one PD source once an insulation fault occurs in the transformer oil. This study, which has both theoretical and practical significance, proposes a method of identifying multiple PD sources in the transformer oil. The method combines the two-sided correlation transformation algorithm in the broadband signal focusing and the modified Gerschgorin disk estimator. The method of classification of multiple signals is used to determine the directions of arrival of signals from multiple PD sources. The ultrasonic array positioning method is based on the multi-platform direction finding and the global optimization searching. Both the 4 × 4 square planar ultrasonic sensor array and the ultrasonic array detection platform are built to test the method of identifying and positioning multiple PD sources. The obtained results verify the validity and the engineering practicability of this method.

  16. Study and optimization of the partial discharges in capacitor model ...

    African Journals Online (AJOL)

    Page 1 ... experiments methodology for the study of such processes, in view of their modeling and optimization. The obtained result is a mathematical model capable to identify the parameters and the interactions between .... 5mn; the next landing is situated in 200 V over the voltage of partial discharges appearance and.

  17. Influences of Traction Load Shock on Artificial Partial Discharge Faults within Traction Transformer—Experimental Test for Pattern Recognition

    Directory of Open Access Journals (Sweden)

    Shuaibing Li

    2017-10-01

    Full Text Available Partial discharge (PD measurement and its pattern recognition are vital to fault diagnosis of transformers, especially to those traction substation transformers undergoing repetitive traction load shocks. This paper presents the primary factors induced by traction load shocks including high total harmonics distortion (THD, transient voltage impulse and high-temperature rise, and their effects on the feature parameters of PD. Experimental tests are conducted on six artificial PD models with these factors introduced one by one. Results reveal that the maximum PD quantity and the PD repetitive rate are favorable to be enlarged when the oil temperature exceeds 80 °C or the THD is higher than 16% with certain orders of harmonic. The decline in PD inception voltage can mainly be attributed to the transient voltage impulse. The variation in central frequency of the fast Fourier transformation (FFT spectra transformed from ultra-high frequency signals can mainly be attributed to high THD, especially when it exceeds 20%. The temperature rise has no significant influence on the FFT spectra; the transient voltage impulse, however, can result in a central frequency shift of the floating particle discharge. With the rapid development of high-speed railways, the study presented in this paper will be helpful for field PD detection and recognition of traction substation transformers in the future.

  18. Temperature Effect on Electrical Treeing and Partial Discharge Characteristics of Silicone Rubber-Based Nanocomposites

    Directory of Open Access Journals (Sweden)

    Mohd Hafizi Ahmad

    2015-01-01

    Full Text Available This study investigated electrical treeing and its associated phase-resolved partial discharge (PD activities in room-temperature, vulcanized silicone rubber/organomontmorillonite nanocomposite sample materials over a range of temperatures in order to assess the effect of temperature on different filler concentrations under AC voltage. The samples were prepared with three levels of nanofiller content: 0% by weight (wt, 1% by wt, and 3% by wt. The electrical treeing and PD activities of these samples were investigated at temperatures of 20°C, 40°C, and 60°C. The results show that the characteristics of the electrical tree changed with increasing temperature. The tree inception times decreased at 20°C due to space charge dynamics, and the tree growth time increased at 40°C due to the increase in the number of cross-link network structures caused by the vulcanization process. At 60°C, more enhanced and reinforced properties of the silicone rubber-based nanocomposite samples occurred. This led to an increase in electrical tree inception time and electrical tree growth time. However, the PD characteristics, particularly the mean phase angle of occurrence of the positive and negative discharge distributions, were insensitive to variations in temperature. This reflects an enhanced stability in the nanocomposite electrical properties compared with the base polymer.

  19. Wireless Sensor Network for Radiometric Detection and Assessment of Partial Discharge in High-Voltage Equipment

    Science.gov (United States)

    Upton, D. W.; Saeed, B. I.; Mather, P. J.; Lazaridis, P. I.; Vieira, M. F. Q.; Atkinson, R. C.; Tachtatzis, C.; Garcia, M. S.; Judd, M. D.; Glover, I. A.

    2018-03-01

    Monitoring of partial discharge (PD) activity within high-voltage electrical environments is increasingly used for the assessment of insulation condition. Traditional measurement techniques employ technologies that either require off-line installation or have high power consumption and are hence costly. A wireless sensor network is proposed that utilizes only received signal strength to locate areas of PD activity within a high-voltage electricity substation. The network comprises low-power and low-cost radiometric sensor nodes which receive the radiation propagated from a source of PD. Results are reported from several empirical tests performed within a large indoor environment and a substation environment using a network of nine sensor nodes. A portable PD source emulator was placed at multiple locations within the network. Signal strength measured by the nodes is reported via WirelessHART to a data collection hub where it is processed using a location algorithm. The results obtained place the measured location within 2 m of the actual source location.

  20. An all-fiber partial discharge monitoring system based on both intrinsic fiber optic interferometry sensor and fluorescent fiber

    Science.gov (United States)

    Yin, Zelin; Zhang, Ruirui; Tong, Jie; Chen, Xi

    2013-12-01

    Partial discharges (PDs) are an electrical phenomenon that occurs within a transformer whenever the voltage stress is sufficient to produce ionization in voids or inclusions within a solid dielectric, at conductor/dielectric interfaces, or in bubbles within liquid dielectrics such as oil; high-frequency transient current discharges will then appear repeatedly and will progressively deteriorate the insulation, ultimately leading to breakdown. Fiber sensor has great potential on the partial discharge detection in high-voltage equipment for its immunity to electromagnetic interference and it can take direct measurement in the high voltage equipment. The energy released in PDs produces a number of effects, resulting in flash, chemical and structural changes and electromagnetic emissions and so on. Acoustic PD detection is based on the mechanical pressure wave emitted from the discharge and fluorescent fiber PD detection is based on the emitted light produced by ionization, excitation and recombination processes during the discharge. Both of the two methods have the shortage of weak anti-interference capacity in the physical environment, like thunder or other sound source. In order to avoid the false report, an all-fiber combined PD detection system of the two methods is developed in this paper. In the system the fluorescent fiber PD sensor is considered as a reference signal, three F-P based PD detection sensors are used to both monitor the PD intensity and calculate the exact position of the discharge source. Considering the wave band of the F-P cavity and the fluorescent probe are quite different, the reflection spectrum of the F-P cavity is in the infrared region, however the fluorescent probe is about 600nm to 700nm, thus the F-P sensor and fluorescent fiber probe can be connected in one fiber and the reflection light can be detected by two different detectors without mutual interference. The all-fiber partial discharge monitoring system not only can detect the PDs

  1. Effect of electric field configuration on streamer and partial discharge phenomena in a hydrocarbon insulating liquid under AC stress

    International Nuclear Information System (INIS)

    Liu, Z; Liu, Q; Wang, Z D

    2016-01-01

    This paper concerns pre-breakdown phenomena, including streamer characteristics from a fundamental perspective and partial discharge (PD) measurements from an industrial perspective, in a hydrocarbon insulating liquid. The aim was to investigate the possible changes of the liquid’s streamer and PD characteristics and their correlations when the uniformity of the AC electric field varies. In the experiments, a plane-to-plane electrode system incorporating a needle protrusion was used in addition to a needle-to-plane electrode system. When the applied electric field became more uniform, fewer radial branches occurred and streamer propagation towards the ground electrode was enhanced. The transition from streamer propagation dominated breakdown in divergent fields to streamer initiation dominated breakdown in uniform fields was evidenced. Relationships between streamer and PD characteristics were established, which were found to be electric field dependent. PD of the same apparent charge would indicate longer streamers if the electric field is more uniform. (paper)

  2. Partial discharge measurements on 110kV current transformers. Setting the control value. Case study

    Science.gov (United States)

    Dan, C.; Morar, R.

    2017-05-01

    The case study presents a series of partial discharge measurements, reflecting the state of insulation of 110kV CURRENT TRANSFORMERS located in Sibiu county substations. Measurements were performed based on electrical method, using MPD600: an acquisition and analysis toolkit for detecting, recording, and analyzing partial discharges. MPD600 consists of one acquisition unit, an optical interface and a computer with dedicated software. The system allows measurements of partial discharge on site, even in presence of strong electromagnetic interferences because it provides synchronous acquisition from all measurement points. Therefore, measurements, with the ability to be calibrated, do render: - a value subject to interpretation according to IEC 61869-1:2007 + IEC 61869-2:2012 + IEC 61869-3:2011 + IEC 61869-5:2011 and IEC 60270: 2000; - the possibility to determine the quantitative limit of PD (a certain control value) to which the equipment can be operated safely and repaired with minimal costs (relative to the high costs implied by eliminating the consequences of a failure) identified empirically (process in which the instrument transformer subjected to the tests was completely destroyed).

  3. Partial discharge location technique for covered-conductor overhead distribution lines

    Energy Technology Data Exchange (ETDEWEB)

    Isa, M.

    2013-02-01

    In Finland, covered-conductor (CC) overhead lines are commonly used in medium voltage (MV) networks because the loads are widely distributed in the forested terrain. Such parts of the network are exposed to leaning trees which produce partial discharges (PDs) in CC lines. This thesis presents a technique to locate the PD source on CC overhead distribution line networks. The algorithm is developed and tested using a simulated study and experimental measurements. The Electromagnetic Transient Program-Alternative Transient Program (EMTP-ATP) is used to simulate and analyze a three-phase PD monitoring system, while MATLAB is used for post-processing of the high frequency signals which were measured. A Rogowski coil is used as the measuring sensor. A multi-end correlation-based technique for PD location is implemented using the theory of maximum correlation factor in order to find the time difference of arrival (TDOA) between signal arrivals at three synchronized measuring points. The three stages of signal analysis used are: (1) denoising by applying discrete wavelet transform (DWT); (2) extracting the PD features using the absolute or windowed standard deviation (STD) and; (3) locating the PD point. The advantage of this technique is the ability to locate the PD source without the need to know the first arrival time and the propagation velocity of the signals. In addition, the faulty section of the CC line between three measuring points can also be identified based on the degrees of correlation. An experimental analysis is performed to evaluate the PD measurement system performance for PD location on CC overhead lines. The measuring set-up is arranged in a high voltage (HV) laboratory. A multi-end measuring method is chosen as a technique to locate the PD source point on the line. A power transformer 110/20 kV was used to energize the AC voltage up to 11.5 kV/phase (20 kV system). The tests were designed to cover different conditions such as offline and online

  4. Partial Discharge Spectral Characterization in HF, VHF and UHF Bands Using Particle Swarm Optimization.

    Science.gov (United States)

    Robles, Guillermo; Fresno, José Manuel; Martínez-Tarifa, Juan Manuel; Ardila-Rey, Jorge Alfredo; Parrado-Hernández, Emilio

    2018-03-01

    The measurement of partial discharge (PD) signals in the radio frequency (RF) range has gained popularity among utilities and specialized monitoring companies in recent years. Unfortunately, in most of the occasions the data are hidden by noise and coupled interferences that hinder their interpretation and renders them useless especially in acquisition systems in the ultra high frequency (UHF) band where the signals of interest are weak. This paper is focused on a method that uses a selective spectral signal characterization to feature each signal, type of partial discharge or interferences/noise, with the power contained in the most representative frequency bands. The technique can be considered as a dimensionality reduction problem where all the energy information contained in the frequency components is condensed in a reduced number of UHF or high frequency (HF) and very high frequency (VHF) bands. In general, dimensionality reduction methods make the interpretation of results a difficult task because the inherent physical nature of the signal is lost in the process. The proposed selective spectral characterization is a preprocessing tool that facilitates further main processing. The starting point is a clustering of signals that could form the core of a PD monitoring system. Therefore, the dimensionality reduction technique should discover the best frequency bands to enhance the affinity between signals in the same cluster and the differences between signals in different clusters. This is done maximizing the minimum Mahalanobis distance between clusters using particle swarm optimization (PSO). The tool is tested with three sets of experimental signals to demonstrate its capabilities in separating noise and PDs with low signal-to-noise ratio and separating different types of partial discharges measured in the UHF and HF/VHF bands.

  5. Defect Pattern Recognition Based on Partial Discharge Characteristics of Oil-Pressboard Insulation for UHVDC Converter Transformer

    Directory of Open Access Journals (Sweden)

    Wen Si

    2018-03-01

    Full Text Available The ultra high voltage direct current (UHVDC transmission system has advantages in delivering electrical energy over long distance at high capacity. UHVDC converter transformer is a key apparatus and its insulation state greatly affects the safe operation of the transmission system. Partial discharge (PD characteristics of oil-pressboard insulation under combined AC-DC voltage are the foundation for analyzing the insulation state of UHVDC converter transformers. The defect pattern recognition based on PD characteristics is an important part of the state monitoring of converter transformers. In this paper, PD characteristics are investigated with the established experimental platform of three defect models (needle-plate, surface discharge and air gap under 1:1 combined AC-DC voltage. The different PD behaviors of three defect models are discussed and explained through simulation of electric field strength distribution and discharge mechanism. For the recognition of defect types when multiple types of sources coexist, the Random Forests algorithm is used for recognition. In order to reduce the computational layer and the loss of information caused by the extraction of traditional features, the preprocessed single PD pulses and phase information are chosen to be the features for learning and test. Zero-padding method is discussed for normalizing the features. Based on the experimental data, Random Forests and Least Squares Support Vector Machine are compared in the performance of computing time, recognition accuracy and adaptability. It is proved that Random Forests is more suitable for big data analysis.

  6. On the Feasibility of Gap Detection of Power Transformer Partial Discharge UHF Signals: Gap Propagation Characteristics of Electromagnetic Waves

    OpenAIRE

    Xiaoxing Zhang; Guozhi Zhang; Yalong Li; Jian Zhang; Rui Huang

    2017-01-01

    This study analyzed the transformer electromagnetic gap propagation characteristics. The influence of gap size is also analyzed, and the results experimentally verified. The obtained results indicated that the gap propagation characteristics of electromagnetic wave signals radiated by the partial discharge (PD) source in different directions are substantially different. The intensity of the electromagnetic wave in the gap reaches a maximum at a gap height of 1 cm; and inside the gap, the inte...

  7. Partial discharge tests and characterisation of the Advanced Photon Source linac modulator cables

    International Nuclear Information System (INIS)

    Cours, A.

    2007-01-01

    The advanced photon source (APS) linac modulators are PFN-type pulsers with switch-mode charging power supplies (PSs). The PS and the PFN are connected to each other by 15 feet of 100-kV x-ray cable, with the PFN end of the cable terminated with a connector that was confirmed partial-discharge (PD)-free up to 38 kV ac (53.5 kV peak). Another end of the cable is terminated with a connector that was designed by the PS manufacturer and cannot easily be replaced with another type of connector, since part of it is located inside the densely packed PS. PD tests of the cables with this type of connector show that the PD inception voltages (PDIVs) in different cables turn out to be located within a wide voltage range: 21 to 27 kV ac that corresponds to 29 to 38 kV peak. In order to evaluate the insulation condition of the modulator cables, detect insulation deterioration, and ensure failure-preventing equipment maintenance, over the last two years the PDIVs of all high-voltage (HV) cables in use in the modulators have been tested about every three and a half months. Before the tests, all cables were removed from the equipment, carefully cleaned, inspected, and regreased. The tests were performed using a 40-kV PD detector. The test results show that: 1 The PDIVs remain almost unchanged in all tested cables. 2 From test to test, the PDIV of any particular cable may slightly oscillate around some average value. This possibly depends on the connector regreasing technique. 3 There is no direct evidence of cable insulation deterioration during more than two years of operation under voltage higher than the PD inception level.

  8. Characterization and comprehension of corona partial discharge in air under power frequency to very low frequency voltage

    Science.gov (United States)

    Yuanxiang, ZHOU; Zhongliu, ZHOU; Ling, ZHANG; Yunxiao, ZHANG; Yajun, MO; Jiantao, SUN

    2018-05-01

    For the partial discharge test of electrical equipment with large capacitance, the use of low-frequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply. However, the validity of PD test under low frequency voltage needs to be evaluated. In order to investigate the influence of voltage frequency on corona discharge in the air, the discharge test of the tip-plate electrode under the frequency from 50 to 0.1 Hz is carried out based on the impulse current method. The results show that some of the main features of corona under low frequency do not change. The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle. The magnitude of discharge and interval in positive cycle are random, while that in negative cycle are regular. With the decrease of frequency, the inception voltage increases. The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated, with discussion and interpretation from the aspects of space charge transportation, effective discharge time and transition of discharge modes. There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency. The experimental results can be the reference for mode identification of partial discharge under low frequency tests. The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency (usually 50 Hz). Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies.

  9. A Rectangular Planar Spiral Antenna for GIS Partial Discharge Detection

    Directory of Open Access Journals (Sweden)

    Xiaoxing Zhang

    2014-01-01

    Full Text Available A rectangular planar spiral antenna sensor was designed for detecting the partial discharge in gas insulation substations (GIS. It can expediently receive electromagnetic waves leaked from basin-type insulators and can effectively suppress low frequency electromagnetic interference from the surrounding environment. Certain effective techniques such as rectangular spiral structure, bow-tie loading, and back cavity structure optimization during the antenna design process can miniaturize antenna size and optimize voltage standing wave ratio (VSWR characteristics. Model calculation and experimental data measured in the laboratory show that the antenna possesses a good radiating performance and a multiband property when working in the ultrahigh frequency (UHF band. A comparative study between characteristics of the designed antenna and the existing quasi-TEM horn antenna was made. Based on the GIS defect simulation equipment in the laboratory, partial discharge signals were detected by the designed antenna, the available quasi-TEM horn antenna, and the microstrip patch antenna, and the measurement results were compared.

  10. Fundamental aspects of excitation and propagation of on-line partial discharge signals in three-phase medium voltage cable systems

    NARCIS (Netherlands)

    Wielen, van der P.C.J.M.; Steennis, E.F.; Wouters, P.A.A.F.

    2003-01-01

    On-line partial discharge (PD) detection of three-phase belted medium voltage cable connections results in a number of interpretation differences as compared to off-line measurements where only one phase is energized. The induced currents and charges in the phase conductors and earth screen upon a

  11. Calibration of ultra-high frequency (UHF) partial discharge sensors using FDTD method

    Science.gov (United States)

    Ishak, Asnor Mazuan; Ishak, Mohd Taufiq

    2018-02-01

    Ultra-high frequency (UHF) partial discharge sensors are widely used for conditioning monitoring and defect location in insulation system of high voltage equipment. Designing sensors for specific applications often requires an iterative process of manufacturing, testing and mechanical modifications. This paper demonstrates the use of finite-difference time-domain (FDTD) technique as a tool to predict the frequency response of UHF PD sensors. Using this approach, the design process can be simplified and parametric studies can be conducted in order to assess the influence of component dimensions and material properties on the sensor response. The modelling approach is validated using gigahertz transverse electromagnetic (GTEM) calibration system. The use of a transient excitation source is particularly suitable for modeling using FDTD, which is able to simulate the step response output voltage of the sensor from which the frequency response is obtained using the same post-processing applied to the physical measurement.

  12. Partial Discharge Monitoring on Metal-Enclosed Switchgear with Distributed Non-Contact Sensors

    Directory of Open Access Journals (Sweden)

    Chongxing Zhang

    2018-02-01

    Full Text Available Metal-enclosed switchgear, which are widely used in the distribution of electrical energy, play an important role in power distribution networks. Their safe operation is directly related to the reliability of power system as well as the power quality on the consumer side. Partial discharge detection is an effective way to identify potential faults and can be utilized for insulation diagnosis of metal-enclosed switchgear. The transient earth voltage method, an effective non-intrusive method, has substantial engineering application value for estimating the insulation condition of switchgear. However, the practical application effectiveness of TEV detection is not satisfactory because of the lack of a TEV detection application method, i.e., a method with sufficient technical cognition and analysis. This paper proposes an innovative online PD detection system and a corresponding application strategy based on an intelligent feedback distributed TEV wireless sensor network, consisting of sensing, communication, and diagnosis layers. In the proposed system, the TEV signal or status data are wirelessly transmitted to the terminal following low-energy signal preprocessing and acquisition by TEV sensors. Then, a central server analyzes the correlation of the uploaded data and gives a fault warning level according to the quantity, trend, parallel analysis, and phase resolved partial discharge pattern recognition. In this way, a TEV detection system and strategy with distributed acquisition, unitized fault warning, and centralized diagnosis is realized. The proposed system has positive significance for reducing the fault rate of medium voltage switchgear and improving its operation and maintenance level.

  13. Partial Discharge Monitoring on Metal-Enclosed Switchgear with Distributed Non-Contact Sensors.

    Science.gov (United States)

    Zhang, Chongxing; Dong, Ming; Ren, Ming; Huang, Wenguang; Zhou, Jierui; Gao, Xuze; Albarracín, Ricardo

    2018-02-11

    Metal-enclosed switchgear, which are widely used in the distribution of electrical energy, play an important role in power distribution networks. Their safe operation is directly related to the reliability of power system as well as the power quality on the consumer side. Partial discharge detection is an effective way to identify potential faults and can be utilized for insulation diagnosis of metal-enclosed switchgear. The transient earth voltage method, an effective non-intrusive method, has substantial engineering application value for estimating the insulation condition of switchgear. However, the practical application effectiveness of TEV detection is not satisfactory because of the lack of a TEV detection application method, i.e., a method with sufficient technical cognition and analysis. This paper proposes an innovative online PD detection system and a corresponding application strategy based on an intelligent feedback distributed TEV wireless sensor network, consisting of sensing, communication, and diagnosis layers. In the proposed system, the TEV signal or status data are wirelessly transmitted to the terminal following low-energy signal preprocessing and acquisition by TEV sensors. Then, a central server analyzes the correlation of the uploaded data and gives a fault warning level according to the quantity, trend, parallel analysis, and phase resolved partial discharge pattern recognition. In this way, a TEV detection system and strategy with distributed acquisition, unitized fault warning, and centralized diagnosis is realized. The proposed system has positive significance for reducing the fault rate of medium voltage switchgear and improving its operation and maintenance level.

  14. Partial discharges and breakdown in C3F8

    International Nuclear Information System (INIS)

    Koch, M; Franck, C M

    2014-01-01

    Traditional search processes of gases or gas mixtures for replacing SF 6 involve time consuming measurements of partial discharges and breakdown behaviour for several voltage waveforms and different field configurations. Recently a model for prediction of this behaviour for SF 6 was described in literature. The model only requires basic properties of the gas such as the critical field strength and the effective ionization coefficient, which can be obtained by swarm parameter measurements, and thermodynamic properties, which can be calculated. In this paper, we show for the well-known and electronegative gas octafluoropropane (C 3 F 8 ) that it is possible to transfer the model developed for SF 6 to this gas to describe the breakdown behaviour of C 3 F 8 . Thus the model can be beneficial in the screening process of new insulation gases. (paper)

  15. Partial discharges and breakdown in C3F8

    Science.gov (United States)

    Koch, M.; Franck, C. M.

    2014-10-01

    Traditional search processes of gases or gas mixtures for replacing SF6 involve time consuming measurements of partial discharges and breakdown behaviour for several voltage waveforms and different field configurations. Recently a model for prediction of this behaviour for SF6 was described in literature. The model only requires basic properties of the gas such as the critical field strength and the effective ionization coefficient, which can be obtained by swarm parameter measurements, and thermodynamic properties, which can be calculated. In this paper, we show for the well-known and electronegative gas octafluoropropane (C3F8) that it is possible to transfer the model developed for SF6 to this gas to describe the breakdown behaviour of C3F8. Thus the model can be beneficial in the screening process of new insulation gases.

  16. On the Feasibility of Gap Detection of Power Transformer Partial Discharge UHF Signals: Gap Propagation Characteristics of Electromagnetic Waves

    Directory of Open Access Journals (Sweden)

    Xiaoxing Zhang

    2017-10-01

    Full Text Available This study analyzed the transformer electromagnetic gap propagation characteristics. The influence of gap size is also analyzed, and the results experimentally verified. The obtained results indicated that the gap propagation characteristics of electromagnetic wave signals radiated by the partial discharge (PD source in different directions are substantially different. The intensity of the electromagnetic wave in the gap reaches a maximum at a gap height of 1 cm; and inside the gap, the intensity of the electromagnetic wave depicted an increasing trend at the tail area of the gap. Finally, from the obtained results, some suggestions on where to install sensors in practical systems for ultra high frequency (UHF PD signal detection in the transformer gap are provided. The obtained results confirmed the feasibility of using this approach. These results can be seen as a benchmark and a challenge for further research in this field.

  17. UHF Signal Processing and Pattern Recognition of Partial Discharge in Gas-Insulated Switchgear Using Chromatic Methodology.

    Science.gov (United States)

    Wang, Xiaohua; Li, Xi; Rong, Mingzhe; Xie, Dingli; Ding, Dan; Wang, Zhixiang

    2017-01-18

    The ultra-high frequency (UHF) method is widely used in insulation condition assessment. However, UHF signal processing algorithms are complicated and the size of the result is large, which hinders extracting features and recognizing partial discharge (PD) patterns. This article investigated the chromatic methodology that is novel in PD detection. The principle of chromatic methodologies in color science are introduced. The chromatic processing represents UHF signals sparsely. The UHF signals obtained from PD experiments were processed using chromatic methodology and characterized by three parameters in chromatic space ( H , L , and S representing dominant wavelength, signal strength, and saturation, respectively). The features of the UHF signals were studied hierarchically. The results showed that the chromatic parameters were consistent with conventional frequency domain parameters. The global chromatic parameters can be used to distinguish UHF signals acquired by different sensors, and they reveal the propagation properties of the UHF signal in the L-shaped gas-insulated switchgear (GIS). Finally, typical PD defect patterns had been recognized by using novel chromatic parameters in an actual GIS tank and good performance of recognition was achieved.

  18. Study on the Application of an Ultra-High-Frequency Fractal Antenna to Partial Discharge Detection in Switchgears

    Directory of Open Access Journals (Sweden)

    Chenguo Yao

    2013-12-01

    Full Text Available The ultra-high-frequency (UHF method is used to analyze the insulation condition of electric equipment by detecting the UHF electromagnetic (EM waves excited by partial discharge (PD. As part of the UHF detection system, the UHF sensor determines the detection system performance in signal extraction and recognition. In this paper, a UHF antenna sensor with the fractal structure for PD detection in switchgears was designed by means of modeling, simulation and optimization. This sensor, with a flat-plate structure, had two resonance frequencies of 583 MHz and 732 MHz. In the laboratory, four kinds of insulation defect models were positioned in the testing switchgear for typical PD tests. The results show that the sensor could reproduce the electromagnetic waves well. Furthermore, to optimize the installation position of the inner sensor for achieving best detection performance, the precise simulation model of switchgear was developed to study the propagation characteristics of UHF signals in switchgear by finite-difference time-domain (FDTD method. According to the results of simulation and verification test, the sensor should be positioned at the right side of bottom plate in the front cabinet. This research established the foundation for the further study on the application of UHF technique in switchgear PD online detection.

  19. On the electrodynamics of partial discharges in voids in solid dielectrics

    DEFF Research Database (Denmark)

    Pedersen, Aage

    1989-01-01

    It is suggested that a correct interpretation of partial-discharge transients can be obtained only through the concept of induced charge. The application of this concept enables a partial-discharge theory to be developed by means of which the influence of relevant void parameters can be assessed ...

  20. Partial discharge patterns related to surface deterioration in voids in epoxy

    DEFF Research Database (Denmark)

    Holbøll, Joachim; Henriksen, Mogens

    1990-01-01

    Results are presented from an investigation of the relationship between changes in partial discharge patterns and the surface deterioration process taking place in small naturally formed spherical voids in epoxy plastic. The voids were exposed to a moderate electric stress above inception level......, where partial discharges were present for more than 1500 h. Two types of electrical tree growth were found, the bush like tree and a single channel-like tree, which led to very different partial discharge patterns. It is concluded that the formation of crystals on a void surface leads to an immediate...... and easy-to-detect increase in the partial discharge activity with subsequent severe surface deterioration (deep pit formations) in the vicinity of the crystal. However, the partial discharge signal from a specimen with a black channel-like tree structure did not give any indication of channel growth...

  1. Solving of some Problems with On-Line Mode Measurement of Partial Discharges

    Directory of Open Access Journals (Sweden)

    Karel Zalis

    2004-01-01

    Full Text Available This paper deals with the problems discussing the transition from off-line diagnostic methods to on-line ones. Based on the experience with commercial partial discharge measuring equipment a new digital system for the evaluation of partial discharge measurement including software and hardware facilities has been developed at the Czech Technical University in Prague. Two expert systems work in this complex evaluating system: a rule-based expert system performing an amplitude analysis of partial discharge impulses for determining the damage of the insulation system, and a neural network which is used for a phase analysis of partial discharge impulses to determine the kind of partial discharge activity. Problem of the elimination of disturbances is also discussed.

  2. Comments on evaluation of energy of partial discharges in ionization chambers

    International Nuclear Information System (INIS)

    Lechowski, Z.

    1980-01-01

    A method of evaluation of energy of partial discharges in ionization chambers which are intended for investigation on electric strength of insulating materials is presented. It is demonstrated that an ionization chamber must be considered as a set of discharge sources and that for energy evaluation an amplitude analysis of apparent charge of discharges is useful. (author)

  3. Excess heat production in Pd/D during periodic pulse discharge current in various conditions

    Energy Technology Data Exchange (ETDEWEB)

    Karabut, A.B. [FSUE ' LUCH' , 24 Zheleznodorozhnaya St., Podolsk, Moscow Region 142100 (Russian Federation)

    2006-07-01

    Experimental date from low-energy nuclear reactions (LENR) in condensed media are presented. The nuclear reactions products were found in solid cathode media used in glow discharge. Apparently, the nuclear reactions were initiated when bombarding the cathode surface by plasma ions with the energy of 1.0 - 2.0 keV. Excess heat from a high current glow discharge reaction in D{sub 2}, Xe, and Kr using cathodes already charged with preliminary deuterium-charged Pd and Ti cathode samples are given. Excess heat up to 10-15 W and efficiency up to 130% were recorded under the experiments for Pd cathode samples in D{sub 2} discharge. Excess heat up to 5 W and efficiency up to 150% were recorded for Pd cathodes that were charged with deuterium before the run, in Xe and Kr discharges. At the same time excess heat was not observed for pure Pd cathode samples in Xe and Kr discharges. The formation of impurity nuclides ({sup 7}Li, {sup 13}C, {sup 15}N, {sup 20}Ne, {sup 29}Si, {sup 44}Ca, {sup 48}Ca, {sup 56}Fe, {sup 57}Fe, {sup 59}Co, {sup 64}Zn, {sup 66}Zn, {sup 75}As, {sup 107}Ag, {sup 109}Ag, {sup 110}Cd, {sup 111}Cd, {sup 112}Cd, {sup 114}Cd and {sup 115}In) with 'the efficiency up to 10{sup 13} at./s was recorded. The isotopic ratios of these new nuclides were quite different from the natural ratios. Soft X-ray radiation from the solid-state cathode with the intensity up to 0.01 Gy/s was recorded in experiments with discharges in H{sub 2}, D{sub 2}, Ar, Xe, and Kr. The X-ray radiation was observed in bursts of up to 10{sup 6} photons, with up to 10{sup 5} bursts per second while the discharge was formed and within 100 ms after turning off the discharge current. The results of the X-ray radiation registration showed that the excited energy levels have a lifetime up to 100 ms or more, and the energy of 1.2 - 2.5 keV. A possible mechanism for producing excess heat and nuclear transmutation reactions in the solid medium with the excited energy levels is considered.

  4. Excess heat production in Pd/D during periodic pulse discharge current in various conditions

    International Nuclear Information System (INIS)

    Karabut, A.B.

    2006-01-01

    Experimental date from low-energy nuclear reactions (LENR) in condensed media are presented. The nuclear reactions products were found in solid cathode media used in glow discharge. Apparently, the nuclear reactions were initiated when bombarding the cathode surface by plasma ions with the energy of 1.0 - 2.0 keV. Excess heat from a high current glow discharge reaction in D 2 , Xe, and Kr using cathodes already charged with preliminary deuterium-charged Pd and Ti cathode samples are given. Excess heat up to 10-15 W and efficiency up to 130% were recorded under the experiments for Pd cathode samples in D 2 discharge. Excess heat up to 5 W and efficiency up to 150% were recorded for Pd cathodes that were charged with deuterium before the run, in Xe and Kr discharges. At the same time excess heat was not observed for pure Pd cathode samples in Xe and Kr discharges. The formation of impurity nuclides ( 7 Li, 13 C, 15 N, 20 Ne, 29 Si, 44 Ca, 48 Ca, 56 Fe, 57 Fe, 59 Co, 64 Zn, 66 Zn, 75 As, 107 Ag, 109 Ag, 110 Cd, 111 Cd, 112 Cd, 114 Cd and 115 In) with 'the efficiency up to 10 13 at./s was recorded. The isotopic ratios of these new nuclides were quite different from the natural ratios. Soft X-ray radiation from the solid-state cathode with the intensity up to 0.01 Gy/s was recorded in experiments with discharges in H 2 , D 2 , Ar, Xe, and Kr. The X-ray radiation was observed in bursts of up to 10 6 photons, with up to 10 5 bursts per second while the discharge was formed and within 100 ms after turning off the discharge current. The results of the X-ray radiation registration showed that the excited energy levels have a lifetime up to 100 ms or more, and the energy of 1.2 - 2.5 keV. A possible mechanism for producing excess heat and nuclear transmutation reactions in the solid medium with the excited energy levels is considered

  5. Partial discharge patterns and surface deterioration in voids in filled and unfilled epoxy

    DEFF Research Database (Denmark)

    Holbøll, Joachim; Henriksen, Mogens

    1992-01-01

    /height analyses were performed over a period of 2400 h and showed very characteristic discharge patterns for each material combination. A unique behavior with regard to changes of pulse repetition rate and maximum apparent charge was observed for PD in alumina- and silica-filled epoxy. The void surfaces were...

  6. On the Use of Monopole Antennas for Determining the Effect of the Enclosure of a Power Transformer Tank in Partial Discharges Electromagnetic Propagation.

    Science.gov (United States)

    Albarracín, Ricardo; Ardila-Rey, Jorge Alfredo; Mas'ud, Abdullahi Abubakar

    2016-01-25

    A well-defined condition-monitoring for power transformers is key to implementing a correct condition-based maintenance (CBM). In this regard, partial discharges (PD) measurement and its analysis allows to carry out on-line maintenance following the standards IEC-60270 and IEC-60076. However, new PD measurements techniques, such as acoustics or electromagnetic (EM) acquisitions using ultra-high-frequency (UHF) sensors are being taken into account, IEC-62478. PD measurements with antennas and the effect of their EM propagation in power transformer tanks is an open research topic that is considered in this paper. In this sense, an empty tank model is studied as a rectangular cavity and their resonances are calculated and compared with their measurement with a network analyser. Besides, two low cost improved monopole antennas deployed inside and outside of the tank model capture background noise and PD pulses in three different test objects (Nomex, twisted pair and insulator). The average spectrum of them are compared and can be found that mainly, the antenna frequency response, the frequency content distribution depending on the PD source and the enclosure resonances modes are the main factors to be considered in PD acquisitions with these sensors. Finally, with this set-up, it is possible to measure PD activity inside the tank from outside.

  7. Application to the system of insulated of diagnosis in high-voltage motors by partial discharge

    International Nuclear Information System (INIS)

    Mikami, M.

    2005-01-01

    In order to detect electric insulators degradation of high-voltage electric motors at an early stage, measurements of partial discharge of operating high-voltage electric motors (about 150 units) in the nuclear power plants were conducted from 2001 to 2004 by the use of on-line monitoring systems that could measure partial discharge of electric insulators. Influencing factors for measured values were identified from measured data and evaluation criteria of electric insulators integrity were established based on variations of partial discharge values. (T. Tanaka)

  8. Partial oxidation of methane in a temperature-controlled dielectric barrier discharge reactor

    KAUST Repository

    Zhang, Xuming; Cha, Min

    2015-01-01

    We studied the relative importance of the reduced field intensity and the background reaction temperature in the partial oxidation of methane in a temperature-controlled dielectric barrier discharge reactor. We obtained important mechanistic insight

  9. Partial discharge localization in power transformers based on the sequential quadratic programming-genetic algorithm adopting acoustic emission techniques

    Science.gov (United States)

    Liu, Hua-Long; Liu, Hua-Dong

    2014-10-01

    Partial discharge (PD) in power transformers is one of the prime reasons resulting in insulation degradation and power faults. Hence, it is of great importance to study the techniques of the detection and localization of PD in theory and practice. The detection and localization of PD employing acoustic emission (AE) techniques, as a kind of non-destructive testing, plus due to the advantages of powerful capability of locating and high precision, have been paid more and more attention. The localization algorithm is the key factor to decide the localization accuracy in AE localization of PD. Many kinds of localization algorithms exist for the PD source localization adopting AE techniques including intelligent and non-intelligent algorithms. However, the existed algorithms possess some defects such as the premature convergence phenomenon, poor local optimization ability and unsuitability for the field applications. To overcome the poor local optimization ability and easily caused premature convergence phenomenon of the fundamental genetic algorithm (GA), a new kind of improved GA is proposed, namely the sequence quadratic programming-genetic algorithm (SQP-GA). For the hybrid optimization algorithm, SQP-GA, the sequence quadratic programming (SQP) algorithm which is used as a basic operator is integrated into the fundamental GA, so the local searching ability of the fundamental GA is improved effectively and the premature convergence phenomenon is overcome. Experimental results of the numerical simulations of benchmark functions show that the hybrid optimization algorithm, SQP-GA, is better than the fundamental GA in the convergence speed and optimization precision, and the proposed algorithm in this paper has outstanding optimization effect. At the same time, the presented SQP-GA in the paper is applied to solve the ultrasonic localization problem of PD in transformers, then the ultrasonic localization method of PD in transformers based on the SQP-GA is proposed. And

  10. The electric strength of high-voltage transformers insulation at effect of partial dischargers

    International Nuclear Information System (INIS)

    Khoshravan, E.; Zeraatparvar, A.; Gashimov, A.M.; Mehdizadeh, R.N.

    2001-01-01

    Full text : In paper the change of electric strength of high-voltage transformers insulation at the effect of partial discharges with space charge accumulation was investigated. It is revealed that the effect of partial discharges of insulation materials results the reduction of their pulsing electric strength which can restore the own initial value at releasing of saved charge the volume of a material under condition of absence the ineversible structural changes in it. Researches of high-voltage transformers insulation's non-failure operation conditions show, that at increasing of insulation work time in a strong electrical field the reduction of average breakdown voltages with simultaneous increasing of spread in discharge voltage values takes place. It authentically testifies to reduction of short-time discharge voltage of insulation materials during their electrical aging. As the basic reason of insulation electrical aging the partial discharges occurring in gas cavities inside insulation were considered. It is known that the space charges will be formed in insulation elements of high-voltage devices which effects in dielectrical property of these elements including the electric strength and the space charge formation can occur also at partial discharges in an alternating voltage while the service of high-voltage transformers. In the given work the experiments in revealing separate influence partial discharges in pulsing electric strength of insulation materials at presence and at absence inside them the space charge were spent

  11. Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors.

    Science.gov (United States)

    Castro, Bruno; Clerice, Guilherme; Ramos, Caio; Andreoli, André; Baptista, Fabricio; Campos, Fernando; Ulson, José

    2016-08-10

    Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique.

  12. Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors

    Directory of Open Access Journals (Sweden)

    Bruno Castro

    2016-08-01

    Full Text Available Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique.

  13. A Novel Partial Discharge Ultra-High Frequency Signal De-Noising Method Based on a Single-Channel Blind Source Separation Algorithm

    Directory of Open Access Journals (Sweden)

    Liangliang Wei

    2018-02-01

    Full Text Available To effectively de-noise the Gaussian white noise and periodic narrow-band interference in the background noise of partial discharge ultra-high frequency (PD UHF signals in field tests, a novel de-noising method, based on a single-channel blind source separation algorithm, is proposed. Compared with traditional methods, the proposed method can effectively de-noise the noise interference, and the distortion of the de-noising PD signal is smaller. Firstly, the PD UHF signal is time-frequency analyzed by S-transform to obtain the number of source signals. Then, the single-channel detected PD signal is converted into multi-channel signals by singular value decomposition (SVD, and background noise is separated from multi-channel PD UHF signals by the joint approximate diagonalization of eigen-matrix method. At last, the source PD signal is estimated and recovered by the l1-norm minimization method. The proposed de-noising method was applied on the simulation test and field test detected signals, and the de-noising performance of the different methods was compared. The simulation and field test results demonstrate the effectiveness and correctness of the proposed method.

  14. Efficient method for location and detection of partial discharge in transformer oil by DOA estimation of circular array of ultrasonic sensors

    Science.gov (United States)

    Saravanakumar, N.; Sathiyasekar, K.

    2018-01-01

    The electrical insulation failures in oil transformers are mainly occurs due to the inappropriate placing of Partial Discharge (PD) sources. In order to eliminate the insulation defects and also to locate the PD sources in an appropriate location, a new approach called circular array of ultrasonic sensors (CAUS) with various analysis is proposed. At first de-noise the PD signal from the CAUS using the fast independent component analysis (Fast ICA) algorithm. Secondly, the wide band signal from CAUS is converted into narrow band signal by using the total least square algorithm (TLS). Third, parse representation of array covariance vector (SRACV) technique is utilized to separate DOA (Direction of Arrival) in three directions from PD to CAUS. Finally, the PD sources are placed in an appropriate location by using the pitch and azimuth angles of those three DOAs and the exact coordination of three planes are calculated by using the particle swarm optimization algorithm. The simulation result demonstrates the effectiveness of proposed approach in terms of PD location in transformer oil.

  15. Evaluation of deterioration of insulators in high-voltage motors by partial discharge

    International Nuclear Information System (INIS)

    Mikami, Masao

    2003-01-01

    For the purpose of early detection of deterioration of insulators in high-voltage motors which are widely utilized in nuclear power stations, a new type on-line partial discharge monitor developed at INSS was applied to test the deterioration of about 150 sets of high-voltage motors running in nuclear power stations practically. From the results, it is shown that (1) tendency of the deterioration can be obtained by this method in general, (2) the magnitude of the on-line partial discharge hardly correlates with that of off-line measurement, but depends on temperature and other environmental conditions, and (3) by observing phase characteristics of partial discharge, it is possible to make a diagnosis of phase-to-phase tracking in end-winding coils of a stator. (author)

  16. On nuclear DD synthesis at the initial stage of nanosecond vacuum discharge with deuterium-loaded Pd anode

    Science.gov (United States)

    Kurilenkov, Yu K.; Gus'kov, S. Yu; Karpukhin, V. T.; Oginov, A. V.; Samoylov, I. S.

    2018-01-01

    Earlier, there was demonstrated generation of DD neutrons in an interelectrode medium of a low-energy (˜ 1 J) nanosecond vacuum discharge with a hollow cathode and a deuterium-loaded Pd anode. There was revealed essential role of formation of a virtual cathode and a potential well corresponding thereto in the processes of collisional DD synthesis in the interelectrode space. In this work, we have obtained as a result of an experiment and discussed the neutron yield at the very initial stage of the discharge, when the beam of auto-electrons just starts to irradiate the non-ideal surface of the deuterium-loaded Pd anode.

  17. Limpieza de patrones φ,q,n de descargas parciales; Denoising of partial discharge φ,q,n patterns

    Directory of Open Access Journals (Sweden)

    Santiago Alfredo Dorrbercker Drake

    2015-04-01

    Full Text Available La medición de descargas parciales (DP se sustenta en la detección y filtraje de pulsos de corriente que aparecen en una banda de frecuencia que abarca desde los kilohertzios hasta los gigahertzios, por tal motivo los detectores de descargas parciales (DDP poseen sistemas para desagregar dichos pulsos de corriente. Sin embargo, los DDP también permiten el paso de otras señales de alta frecuencia (ruidos que se mezclan con los pulsos de DP y afectan la medición, interpretación y caracterización de las DP. Para atenuar ese efecto, se han desarrollado distintas técnicas para separar los ruidos tanto asociados a las señales como los existentes en los patrones φ,q,n.  En este artículo se presentan los resultados obtenidos en la reducción de los ruidos asociados a la conmutación de tiristores y los ruidos esporádicos, de los patrones φ,q,n mediante el empleo de técnicas de procesamiento de imágenes digitales. The measurement of partial (PD discharges is sustained in the detection and filtration of current pulses which appear in a band of frequency that include from the kilohertz until the gigahertzios, for such a reason the detectors of partial (PDD discharges they possess systems for the separation of this current pulses. However, PDD also allows the step of other signals of high frequency, denominated noises, that mix with the pulses of PD and they affect measurement, interpretation and characterization of PD. To attenuate that effect, different techniques have been developed to separate the noises so much associated to the signs like the existent ones in the φ,q,n patterns. In this paper are presented the results obtained in the noise reduction of the noises associated to the thyristor’s commutation and the sporadic noises, in the φ,q,n patterns by means of the technical of digital images processing

  18. Development of a method of partial discharge detection in extra-high voltage cross-linked polyethylene insulated cable lines

    International Nuclear Information System (INIS)

    Katsuta, G.; Toya, A.; Muraoka, K.; Endoh, T.; Sekii, Y.; Ikeda, C.

    1992-01-01

    This paper reports that deterioration in the insulation performance of extra-high voltage XLPE cables is believed to be attributable to the deterioration caused by partial discharges. In the authors study, after using an XLPE cable to investigate the behavior of partial discharges under various adverse conditions, we succeeded in developing a highly sensitive new method of measuring partial discharge in XLPE cable lines. Partial discharges in a 275 kV XLPE cable live line has been measured using this newly developed method. As a result, a detection sensitivity of 1 pC has been achieved

  19. Influence of bulk dielectric polarization upon partial discharge transients: Effect of void geometry and orientation

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Crichton, G.C.

    2005-01-01

    The induced charge arising from a partial discharge consists of 2 components. One is associated with the actual space charge in the void. The other is related to changes in the polarization of the bulk dielectric. These changes are a direct consequence of the field produced by the space charge...

  20. Virtual-Instrument-Based Online Monitoring System for Hands-on Laboratory Experiment of Partial Discharges

    Science.gov (United States)

    Karmakar, Subrata

    2017-01-01

    Online monitoring of high-voltage (HV) equipment is a vital tool for early detection of insulation failure. Most insulation failures are caused by partial discharges (PDs) inside the HV equipment. Because of the very high cost of establishing HV equipment facility and the limitations of electromagnetic interference-screened laboratories, only a…

  1. Partial Discharge Measurements in HV Rotating Machines in Dependence on Pressure of Coolant

    Directory of Open Access Journals (Sweden)

    I. Kršňák

    2002-01-01

    Full Text Available The influence of the pressure of the coolant used in high voltage rotating machines on partial discharges occurring in stator insulation is discussed in this paper. The first part deals with a theoretical analysis of the topic. The second part deals with the results obtained on a real generator in industrial conditions. Finally, theoretical assumptions and obtained results are compared.

  2. Shoulder replacement - discharge

    Science.gov (United States)

    Total shoulder arthroplasty - discharge; Endoprosthetic shoulder replacement - discharge; Partial shoulder replacement - discharge; Partial shoulder arthroplasty - discharge; Replacement - shoulder - discharge; Arthroplasty - shoulder - discharge

  3. Acoustic position finding of partial discharges in transformers. Combination of partial discharge measurement technology with 3D visualization; Akustische Ortung von Teilentladungen in Transformatoren. TE-Messtechnik und 3-D-Visualisierung kombiniert

    Energy Technology Data Exchange (ETDEWEB)

    Kraetge, Alexander; Hoek, Stefan [Omicron Electronics GmbH, Klaus (Austria)

    2013-11-01

    A new measuring system facilitates the detection of partial discharges in transformers by means of the fully synchronous combination of measurement technology for electrical partial discharges with intuitive 3D visualization of the test object. The contribution under consideration describes the application of this system with examples from the measurement practice.

  4. Comparing PD results with visual inspection

    International Nuclear Information System (INIS)

    Rossi, A.; Stone, G.C.

    2005-01-01

    ENEL is the main generation utility in Italy, with more than 200 hydro units and 120 turbine generators, totaling 39,000 MW of capacity. To help identify the maintenance needs of the stator windings in these units, ENEL has been gradually equipping the generators with partial discharge (PD) sensors that facilitate an on-line measurement of the PD. The paper describes results from several machines that have PD. In all cases, the high PD was confirmed by visual inspections. Although PD usually found the units with severe insulation problems, it was not always possible to determine the causes of the deterioration from the PD pattern. (author)

  5. On-line Monitoring Device for High-voltage Switch Cabinet Partial Discharge Based on Pulse Current Method

    Science.gov (United States)

    Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.

    2017-12-01

    The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.

  6. Ageing of insulation and diagnosis of electrical equipment through detection of partial discharge

    International Nuclear Information System (INIS)

    Lopez Vergara, T.; Velasco Bernal, C.

    1994-01-01

    Ageing in electrical equipment affects mainly its insulation system. Such ageing in the insulation system is determined by its organic nature, basically constituted by three families of materials: cellulose, resin and hydrocarbon. All of these are affected by high temperatures, which tend to produce a break in the molecular chains (if the temperatures are not too high) or carbonization and gasification of the material (if they are). The radiation absorbed by the insulating materials also destroys molecular chains, causing degradation of the material. The break of the molecular chains, especially in the polymer-based materials, fragments the material, mainly in areas subjected to mechanical forces and stresses. From the electrical point of view, fissures occurring the insulating material lead to a much lower dielectric strength in certain parts of the materials, which could produce partial discharge conditions. Therefore, the growth of partial discharges in electrical equipment items is frequently the consequences of ageing, and be used to evaluate their residual life. Empresarios Agrupados has developed a system to detect partial discharges which can be used while equipment is still in operation. The measurements taken with this system are sufficiently accurate and repetitive to be used in evaluating the condition of medium-voltage electrical equipment insulation. (Author)

  7. Moisture Migration in an Oil-Paper Insulation System in Relation to Online Partial Discharge Monitoring of Power Transformers

    Directory of Open Access Journals (Sweden)

    Wojciech Sikorski

    2016-12-01

    Full Text Available Most power transformers operating in a power system possess oil-paper insulation. A serious defect of this type of insulation, which is associated with long operation time, is an increase in the moisture content. Moisture introduces a number of threats to proper operation of the transformer, e.g., ignition of partial discharges (PDs. Due to the varying temperature of the insulation system during the unit’s normal operation, a dynamic change (migration of water takes place, precipitating the oil-paper system from a state of hydrodynamic equilibrium. This causes the PDs to be variable in time, and they may intensify or extinguish. Studies on model objects have been conducted to determine the conditions (temperature, humidity, time that will have an impact on the ignition and intensity of the observed phenomenon of PDs. The conclusions of this study will have a practical application in the evaluation of measurements conducted in the field, especially in relation to the registration of an online PD monitoring system.

  8. Partial oxidation of methane in a temperature-controlled dielectric barrier discharge reactor

    KAUST Repository

    Zhang, Xuming

    2015-01-01

    We studied the relative importance of the reduced field intensity and the background reaction temperature in the partial oxidation of methane in a temperature-controlled dielectric barrier discharge reactor. We obtained important mechanistic insight from studying high-temperature and low-pressure conditions with similar reduced field intensities. In the tested range of background temperatures (297 < T < 773 K), we found that the conversion of methane and oxygen depended on both the electron-induced chemistry and the thermo-chemistry, whereas the chemical pathways to the products were overall controlled by the thermo-chemistry at a given temperature. We also found that the thermo-chemistry enhanced the plasma-assisted partial oxidation process. Our findings expand our understanding of the plasma-assisted partial oxidation process and may be helpful in the design of cost-effective plasma reformers. © 2014 The Combustion Institute.

  9. Synthesis of AuPd alloyed nanoparticles via room-temperature electron reduction with argon glow discharge as electron source.

    Science.gov (United States)

    Yang, Manman; Wang, Zongyuan; Wang, Wei; Liu, Chang-Jun

    2014-01-01

    Argon glow discharge has been employed as a cheap, environmentally friendly, and convenient electron source for simultaneous reduction of HAuCl4 and PdCl2 on the anodic aluminum oxide (AAO) substrate. The thermal imaging confirms that the synthesis is operated at room temperature. The reduction is conducted with a short time (30 min) under the pressure of approximately 100 Pa. This room-temperature electron reduction operates in a dry way and requires neither hydrogen nor extra heating nor chemical reducing agent. The analyses using X-ray photoelectron spectroscopy (XPS) confirm all the metallic ions have been reduced. The characterization with X-ray diffraction (XRD) and high-resolution transmission electron microscopy (HRTEM) shows that AuPd alloyed nanoparticles are formed. There also exist some highly dispersed Au and Pd monometallic particles that cannot be detected by XRD and transmission electron microscopy (TEM) because of their small particle sizes. The observed AuPd alloyed nanoparticles are spherical with an average size of 14 nm. No core-shell structure can be observed. The room-temperature electron reduction can be operated in a larger scale. It is an easy way for the synthesis of AuPd alloyed nanoparticles.

  10. Statistical Analysis of Partial Discharge Characteristics in Transformer Oil at the “Point-Plane” Electrode at Alternating Voltage

    Directory of Open Access Journals (Sweden)

    Korobeynikov S.M.

    2017-08-01

    Full Text Available In this paper, we consider the problems related to measuring and analyzing the characteristics of partial discharges which are the main instrument for oil-filled high-voltage electrical equipment diagnosing. The experiments on recording of partial discharges in transformer oil have been carried out in the “point-plane” electrode system at alternating current. The instantaneous voltage and the apparent charge have been measured depending on the root-mean-square voltage and the phase angle of partial discharges. This paper aimes at carrying out a statistical analysis of the obtained experimental results, in particular, the construction of a parametric probabilistic model of the dependence of the partial discharge inception voltage distribution on the value of the root-mean-square voltage. It differs from usual discharges which occur in liquid dielectric materials in case of sharp inhomogeneous electrode system. It has been suggested that discharges of a different type are the discharges in gas bubbles that occur when partial discharges in a liquid emerge. This assumption is confirmed by the fact that the number of such discharges increases with increasing the root-mean-square voltage value. It is the main novelty of this paper. This corresponds to the nature of the occurrence of such discharges. After rejecting the observations corresponding to discharges in gas bubbles, a parametric probabilistic model has been constructed. The model obtained makes it possible to determine the probability of partial discharge occurrence in a liquid at a given value of the instantaneous voltage depending on the root-mean-square voltage.

  11. Effectiveness of Partition and Graph Theoretic Clustering Algorithms for Multiple Source Partial Discharge Pattern Classification Using Probabilistic Neural Network and Its Adaptive Version: A Critique Based on Experimental Studies

    Directory of Open Access Journals (Sweden)

    S. Venkatesh

    2012-01-01

    Full Text Available Partial discharge (PD is a major cause of failure of power apparatus and hence its measurement and analysis have emerged as a vital field in assessing the condition of the insulation system. Several efforts have been undertaken by researchers to classify PD pulses utilizing artificial intelligence techniques. Recently, the focus has shifted to the identification of multiple sources of PD since it is often encountered in real-time measurements. Studies have indicated that classification of multi-source PD becomes difficult with the degree of overlap and that several techniques such as mixed Weibull functions, neural networks, and wavelet transformation have been attempted with limited success. Since digital PD acquisition systems record data for a substantial period, the database becomes large, posing considerable difficulties during classification. This research work aims firstly at analyzing aspects concerning classification capability during the discrimination of multisource PD patterns. Secondly, it attempts at extending the previous work of the authors in utilizing the novel approach of probabilistic neural network versions for classifying moderate sets of PD sources to that of large sets. The third focus is on comparing the ability of partition-based algorithms, namely, the labelled (learning vector quantization and unlabelled (K-means versions, with that of a novel hypergraph-based clustering method in providing parsimonious sets of centers during classification.

  12. On-line Monitoring System Based on Principle of Electro-acoustic Monitoring for Transformer Partial Discharge

    Directory of Open Access Journals (Sweden)

    Guang Ya LIU

    2014-02-01

    Full Text Available Partial discharge inside a transformer is mainly responsible for the insulation aging and damage of the transformer. However, partial discharge is usually accompanied by external signals like sound, light and electrical signals and detectable physical phenomena such as characteristical gas and dielectric loss. Therefore, it is of great significance to monitor online the external signals and phenomena formed during partial discharge of the transformer when the transformer diagnoses faults. This paper gives a comprehensive overview of the electro-acoustic joint monitoring principles and its monitoring systems and the judgment skills concerned, on the basis of which the monitoring system is designed.

  13. Method for measuring the stochastic properties of corona and partial-discharge pulses

    International Nuclear Information System (INIS)

    Van Brunt, R.J.; Kulkarni, S.V.

    1989-01-01

    A new method is described for measuring the stochastic behavior of corona and partial-discharge pulses which utilizes a pulse selection and sorting circuit in conjunction with a computer-controlled multichannel analyzer to directly measure various conditional and unconditional pulse-height and pulse-time-separation distributions. From these measured distributions it is possible to determine the degree of correlation between successive discharge pulses. Examples are given of results obtained from measurements on negative, point-to-plane (Trichel-type) corona pulses in a N 2 /O 2 gas mixture which clearly demonstrate that the phenomenon is inherently stochastic in the sense that development of a discharge pulse is significantly affected by the amplitude of and time separation from the preceding pulse. It is found, for example, that corona discharge pulse amplitude and time separation from an earlier pulse are not independent random variables. Discussions are given about the limitations of the method, sources of error, and data analysis procedures required to determine self-consistency of the various measured distributions

  14. Fiber Fabry-Perot sensors for detection of partial discharges in power transformers.

    Science.gov (United States)

    Yu, Bing; Kim, Dae Woong; Deng, Jiangdong; Xiao, Hai; Wang, Anbo

    2003-06-01

    A diaphragm-based interferometric fiberoptic sensor that uses a low-coherence light source was designed and tested for on-line detection of the acoustic waves generated by partial discharges inside high-voltage power transformers. The sensor uses a fused-silica diaphragm and a single-mode optical fiber encapsulated in a fused-silica glass tube to form an extrinsic Fabry-Perot interferometer, which is interrogated by low-coherence light. Test results indicate that these fiber optic acoustic sensors are capable of faithfully detecting acoustic signals propagating inside transformer oil with high sensitivity and wide bandwidth.

  15. Facile synthesis of Pt–Pd bimetallic nanoparticles by plasma discharge in liquid and their electrocatalytic activity toward methanol oxidation in alkaline media

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung-Min; Lee, Yu-Jin [Center for Surface Technology and Applications, Korea Aerospace University, Gyeonggi-do, 412-791 (Korea, Republic of); Department of Materials Engineering, Korea Aerospace University, Gyeonggi-do, 412-791 (Korea, Republic of); Kim, Jung-Wan [Center for Surface Technology and Applications, Korea Aerospace University, Gyeonggi-do, 412-791 (Korea, Republic of); Division of Bioengineering, InCheon National University, Incheon, 406-772 (Korea, Republic of); Lee, Sang-Yul, E-mail: sylee@kau.ac.kr [Center for Surface Technology and Applications, Korea Aerospace University, Gyeonggi-do, 412-791 (Korea, Republic of); Department of Materials Engineering, Korea Aerospace University, Gyeonggi-do, 412-791 (Korea, Republic of)

    2014-12-01

    The Pt–Pd bimetallic nanoparticles for direct methanol fuel cell applications were successfully prepared by plasma discharge in aqueous solution. The obtained nanoparticles were characterized by energy dispersive X-ray spectroscopy, X-ray diffraction spectroscopy, and transmission electron microscopy. During plasma discharge, the nanoparticles were produced from the erosion of electrodes. It was noted that the erosion amount of anode electrodes was much greater than that of cathode electrodes so that the composition of Pt–Pd bimetallic nanoparticles could be changed with different power types and electrode configurations. Diffraction patterns fitted from Gaussian devolution indicated that the crystalline phase of Pt{sub 40}Pd{sub 60} products was composed of pure Pt, pure Pd and Pt–Pd alloy phases. The morphology of synthesized nanoparticles showed that nanowires connected with quasi-spherical nanoparticles with 2–3 nm in diameter were observed and large spherical particles with > 50 nm in diameter were also detected intermittently. The cyclic voltammetric measurement and continuous potential scan demonstrated that Pt{sub 40}Pd{sub 60} had much higher catalytic activity and better resistance to CO poisoning than Pt{sub 94}Pd{sub 6} and Pt{sub 1}Pd{sub 99} for methanol oxidation. These results indicate that the Pt{sub 40}Pd{sub 60} could be an excellent candidate for the direct methanol fuel cell applications.

  16. Partial Discharge Detection Using Low Cost RTL-SDR Model for Wideband Spectrum Sensing

    DEFF Research Database (Denmark)

    Mohamed, H.; Lazaridis, Pavlos; Upton, D.

    2016-01-01

    an optimal approach for PD signal analysis, and are very costly. In this paper an RTLSDR (Software Defined Radio) based spectrum analyser has been proposed in order to provide a potentially low cost solution for PD detection and monitoring. Initially, a portable spectrum analyser has been used for PD...

  17. Development and verification of a software tool for the acoustic location of partial discharge in a power transformer

    Directory of Open Access Journals (Sweden)

    Polužanski Vladimir

    2014-01-01

    Full Text Available This paper discusses the development and verification of software tool for determining the location of partial discharge in a power transformer with the acoustic method. Classification and systematization of physical principles and detection methods and tests of partial discharge in power transformers are shown at the beginning of this paper. The most important mathematical models, features, algorithms, and real problems that affect measurement accuracy are highlighted. This paper describes the development and implementation of a software tool for determining the location of partial discharge in a power transformer based on a no iterative mathematical algorithm. Verification and accuracy of measurement are proved both by computer simulation and experimental results available in the literature.

  18. Analysis of Partial Discharge Activity for Evaluation of the State of High Power Electric Generators Stator Windings

    Directory of Open Access Journals (Sweden)

    Dumitrescu Sorin

    2016-08-01

    Full Text Available The paper shows the importance of trending of partial discharge activity in assessing the insulation condition. It is presented the principle of the measurement method and the quantities that characterize partial discharges and also the criteria utilized for the assessement of the insulation condition of the hydrogenerators. Results of the measurements made on several hydrogenerators are presented, like the variation with time of the two main quantities that characterize the partial discharges, maximum magnitude, Qm and the normalized quantity, NQN over a period of about 10 years. Further, a classification of the insulation condition by 3 main and 2 intermediary categories and the definition of these categories are given. The criteria used for the assessment of the insulation condition are presented in the form of a table: quantitative criteria by the ± NQN and ± Qm values and qualitative criteria for the analysis of the 2D and 3D diagrams. At the end of each set of measurements, an analyze of the insulation condition annual evaluation is made, also a verdict is put, and of course, the recommendations made relating to the maintenance and the decisions that have been taken. The paper ends with several considerations on the method of on-line partial discharges and especially, on the conditions for valid trending activity in time.

  19. Antenna Deployment for the Localization of Partial Discharges in Open-Air Substations

    Science.gov (United States)

    Robles, Guillermo; Fresno, José Manuel; Sánchez-Fernández, Matilde; Martínez-Tarifa, Juan Manuel

    2016-01-01

    Partial discharges are ionization processes inside or on the surface of dielectrics that can unveil insulation problems in electrical equipment. The charge accumulated is released under certain environmental and voltage conditions attacking the insulation both physically and chemically. The final consequence of a continuous occurrence of these events is the breakdown of the dielectric. The electron avalanche provokes a derivative of the electric field with respect to time, creating an electromagnetic impulse that can be detected with antennas. The localization of the source helps in the identification of the piece of equipment that has to be decommissioned. This can be done by deploying antennas and calculating the time difference of arrival (TDOA) of the electromagnetic pulses. However, small errors in this parameter can lead to great displacements of the calculated position of the source. Usually, four antennas are used to find the source but the array geometry has to be correctly deployed to have minimal errors in the localization. This paper demonstrates, by an analysis based on simulation and also experimentally, that the most common layouts are not always the best options and proposes a simple antenna layout to reduce the systematic error in the TDOA calculation due to the positions of the antennas in the array. PMID:27092501

  20. Comparison of capacitive and inductive sensors designed for partial discharges measurements in electrical power apparatus

    Directory of Open Access Journals (Sweden)

    Kunicki Michał

    2017-01-01

    Full Text Available In the paper results of simultaneously conducted measurements achieved using capacitive and inductive sensors are presented according to different PD model sources immersed in a mineral transformer insulation oil. All measurements are preceded under laboratory conditions using typical measurement set up commonly applied for on-site PD detection: measuring impedance and capacitor and high frequency current transformer (HFCT are used respectively. Measuring frequency and voltage level influence as well as phase resolved PD patterns analysis are investigated in the research. Various fundamental PD signal descriptors assigned for selected frequencies are also proposed and compared for chosen sensors. The main purpose of the presented research is to compare PD measurement results achieved using selected type of sensors during laboratory measurements and to point the best application areas in fields of PD detection in high voltage apparatus under normal operating conditions. Furthermore a proper measurement results interpretation coming from different sensors as well as measurement conducting problems and achieved patterns disparities are also discussed in the paper.

  1. Evaluation efficiency for mobile as discharge measurement device for partially filled circular channel

    Directory of Open Access Journals (Sweden)

    I.M.H. Rashwan

    2013-06-01

    Full Text Available Discharge measurement is an important step in engineering applications such as sewerage system, irrigation and drainage system. Mobile flume is a simple and low-cost discharge measuring device constructed of two pieces of pipes, one installed vertically inside the other. The circular mobile flume depends on the concept of developing a contracted zone to have a control section. To evaluate the efficiency of this type of device mathematical and experimental studies are presented. Specific energy, discharge and Froude number equations are used to develop mathematical model. Experimental work is carried out to measure the discharge values corresponding to the specific energy values. The experimental data is used to evaluate the mobile flume as a device to measure discharge. A new equation for the discharge coefficient is presented. This equation can be used to determined accurate discharge with knowing the contraction ratio and measured specific energy.

  2. Possibility of a two-dimensional spin liquid in CePdAl induced by partial geometric frustration?

    Energy Technology Data Exchange (ETDEWEB)

    Fritsch, V. [Universitaet Augsburg, Institut fuer Physik, Experimentalphysik VI (Germany); Karlsruher Institut fuer Technologie (Germany); Grube, K.; Kittler, W.; Taubenheim, C.; Loehneysen, H. von [Karlsruher Institut fuer Technologie (Germany); Huesges, Z.; Lucas, S.; Stockert, O. [Max-Planck-Institut fuer chemische Physik fester Stoffe, Dresden (Germany); Green, E. [Hochfeldzentrum Dresden-Rossendorf (Germany)

    2015-07-01

    CePdAl crystallizes in the hexagonal ZrNiAl structure, where the magnetic ions form a distorted kagome lattice. At T{sub N} = 2.7 K the onset of antiferromagnetic (AF) order is observed. Neutron scattering experiments revealed a partial frustration in the distorted kagome planes of this structure: two-thirds of the Ce moments form ferromagnetic chains, which are antiferromagnetically coupled, the remaining third do not participate in any long-range order. Along the c-axis the magnetic moments exhibit an amplitude modulation. Accordingly, the kagome planes are stacked on top of each other, resulting in corrugated AF planes parallel to the c-axis formed by the ordered magnetic moments, which are separated by the frustrated moments. It is an intriguing and yet unresolved question if this third of frustrated moments forms a spin liquid state in CePdAl. Based on measurements of specific heat, thermal expansion, magnetization and electrical resistivity we want to discuss this possibility.

  3. Development of acoustic partial discharge detection device; Bubun hoden kenshutsusochi wo riyo shita onkyo niyoru hendensetsubi no zetsuen rekka shindan gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Kiyoka [Kawasaki Steel Corp., Tokyo (Japan)

    1999-06-15

    This paper introduces an acoustic partial discharge detection device, consisting of a microphone, amplifier circuit for analog signals, A/D (Digital Signal Processor). This device has the following unique characteristics: (1) Judging whether or not there is partial discharge by analyzing supersonic signals. (2) High sensitivity for detecting discharge ; 100 pC from a distance of 1.2 m. (3)Locating the position of discharge occurrence by using a sharpe directional parabola microphone and laser beam pointer. The detector was used in the steel works to detect partial discharge on high-voltage electrical apparatus, where faults due to partial discharge were found in the potential transformer and current transformer. The effectiveness of the device was thus verified. (author)

  4. Oscillatory behaviour of catalytic properties, structure and temperature during the catalytic partial oxidation of methane on Pd/Al2O3

    DEFF Research Database (Denmark)

    Kimmerle, B.; Baiker, A.; Grunwaldt, Jan-Dierk

    2010-01-01

    Pd/Al2O3 catalysts showed an oscillatory behaviour during the catalytic partial oxidation (CPO) of methane, which was investigated simultaneously by IR-thermography, X-ray absorption spectroscopy, and online mass-spectrometry to correlate the temperature, state of the catalyst and catalytic...... to self-reduction leading to extinction of the process. The latter was the key driver for the oscillations and thus gave additional insight into the mechanism of partial methane oxidation....

  5. Analysis of the Sensitivity of K-Type Molecular Sieve-Deposited MWNTs for the Detection of SF₆ Decomposition Gases under Partial Discharge.

    Science.gov (United States)

    Zhang, Xiaoxing; Li, Xin; Luo, Chenchen; Dong, Xingchen; Zhou, Lei

    2015-11-11

    Sulfur hexafluoride (SF6) is widely utilized in gas-insulated switchgear (GIS). However, part of SF6 decomposes into different components under partial discharge (PD) conditions. Previous research has shown that the gas responses of intrinsic and 4 Å-type molecular sieve-deposited multi-wall carbon nanotubes (MWNTs) to SOF2 and SO2F2, two important decomposition components of SF6, are not obvious. In this study, a K-type molecular sieve-deposited MWNTs sensor was developed. Its gas response characteristics and the influence of the mixture ratios of gases on the gas-sensing properties were studied. The results showed that, for sensors with gas mixture ratios of 5:1, 10:1, and 20:1, the resistance change rate increased by nearly 13.0% after SOF2 adsorption, almost 10 times that of MWNTs sensors, while the sensors' resistance change rate with a mixture ratio of 10:1 reached 17.3% after SO2F2 adsorption, nearly nine times that of intrinsic MWNT sensors. Besides, a good linear relationship was observed between concentration of decomposition components and the resistance change rate of sensors.

  6. Analysis of the Sensitivity of K-Type Molecular Sieve-Deposited MWNTs for the Detection of SF6 Decomposition Gases under Partial Discharge

    Science.gov (United States)

    Zhang, Xiaoxing; Li, Xin; Luo, Chenchen; Dong, Xingchen; Zhou, Lei

    2015-01-01

    Sulfur hexafluoride (SF6) is widely utilized in gas-insulated switchgear (GIS). However, part of SF6 decomposes into different components under partial discharge (PD) conditions. Previous research has shown that the gas responses of intrinsic and 4 Å-type molecular sieve-deposited multi-wall carbon nanotubes (MWNTs) to SOF2 and SO2F2, two important decomposition components of SF6, are not obvious. In this study, a K-type molecular sieve-deposited MWNTs sensor was developed. Its gas response characteristics and the influence of the mixture ratios of gases on the gas-sensing properties were studied. The results showed that, for sensors with gas mixture ratios of 5:1, 10:1, and 20:1, the resistance change rate increased by nearly 13.0% after SOF2 adsorption, almost 10 times that of MWNTs sensors, while the sensors’ resistance change rate with a mixture ratio of 10:1 reached 17.3% after SO2F2 adsorption, nearly nine times that of intrinsic MWNT sensors. Besides, a good linear relationship was observed between concentration of decomposition components and the resistance change rate of sensors. PMID:26569245

  7. Analysis of the Sensitivity of K-Type Molecular Sieve-Deposited MWNTs for the Detection of SF6 Decomposition Gases under Partial Discharge

    Directory of Open Access Journals (Sweden)

    Xiaoxing Zhang

    2015-11-01

    Full Text Available Sulfur hexafluoride (SF6 is widely utilized in gas-insulated switchgear (GIS. However, part of SF6 decomposes into different components under partial discharge (PD conditions. Previous research has shown that the gas responses of intrinsic and 4 Å-type molecular sieve-deposited multi-wall carbon nanotubes (MWNTs to SOF2 and SO2F2, two important decomposition components of SF6, are not obvious. In this study, a K-type molecular sieve-deposited MWNTs sensor was developed. Its gas response characteristics and the influence of the mixture ratios of gases on the gas-sensing properties were studied. The results showed that, for sensors with gas mixture ratios of 5:1, 10:1, and 20:1, the resistance change rate increased by nearly 13.0% after SOF2 adsorption, almost 10 times that of MWNTs sensors, while the sensors’ resistance change rate with a mixture ratio of 10:1 reached 17.3% after SO2F2 adsorption, nearly nine times that of intrinsic MWNT sensors. Besides, a good linear relationship was observed between concentration of decomposition components and the resistance change rate of sensors.

  8. Dielectric strength behaviour and mechanical properties of transparent insulation materials suitable to optical monitoring of partial discharges

    International Nuclear Information System (INIS)

    Lothongkam, Chaiyaporn

    2014-01-01

    A novel optical detection method for partial discharge in HV/EHV cable terminations has been proposed. Optical sensor fibres integrated into the HV equipment provide high sensitivity as well as immunity to electromagnetic interference and enable therefore on-line monitoring in electromagnetically noisy environment. The availability of optically transparent silicone rubbers that meet strict dielectric and mechanical criteria is a crucial prerequisite for the implementation of this method. The optically transparent silicone rubbers can be applied for the fabrication of a modern rubber stress cone as well as for the development of a new optical sensing element sensitive to PD activities. In this thesis, AC dielectric strength behaviour and mechanical properties of three types of commercially available silicone rubbers were investigated. One of the characterized silicone rubbers was a translucent type whereas the two others were optically transparent types, however with different chemical curing reactions. The measurements of tensile strength and elongation at break were carried out according to the ISO 37 standard. For investigation of the dielectric strength E b behaviour of the virgin and modified silicone rubbers, a new methodology was developed. It is, at the same time, highly reliable and efficient, saves time and reduces material consumption in comparison to previously reported methodologies. The key component of this methodology is a specifically developed test facility. Furthermore, the methodology comprises determinations for easy preparation and handling of high-quality test specimens. This test method provides various advantages over other methods that have previously been used for measurement of the fundamental quantity E b value of silicone rubbers. Both technical and economic demands are satisfied. The new facility also enables cost-effective routine tests in material research laboratories. The high quality of the obtained test results was verified by

  9. On-line diagnosis of high power motors based on ultra wide band partial discharge detection; Diagnostico en linea de motores de gran capacidad mediante la deteccion de descargas parciales utilizando tecnicas de banda ultra ancha

    Energy Technology Data Exchange (ETDEWEB)

    Carvajal M, F. Antonio; Garcia Colon H, Vicente R. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Asiain, Tomas [Instituto Politecnico Nacional, Escuela Superior de Ingenieria Mecanica y Electrica (Mexico)

    2009-07-01

    In this work a non-standardized method for on-line diagnostic of high capacity motors based on Ultra Wide Band (UWB) Partial Discharge (PD) measuring techniques is theoretically supported, implemented and applied. The method developed is non invasive and consist in the measurement of PD in the main motor power supply cables and its ground shields connection using a near field sensor (Rogowski coil, clamp-on type) with a bandwidth of 2 to 40 MHz. The measured signals by the sensor, are stretched electronically, digitized and fed to a conventional Partial Discharge digital detector. The UWB PD detection system used displays the output in a Pulse repetition frequency-Charge-Phase angle (N-Q-?) PD pattern. The results obtained in thirteen 2500 H.P., 13.8 kV motors performed during operating in an Oil Pumping facility are presented, including its analysis and comparison with values and PD patterns reported in literature. [Spanish] En este trabajo se presentan los fundamentos teoricos, la implementacion y aplicacion de un metodo no normalizado, para el diagnostico en linea de motores de gran capacidad, basado en la deteccion de Descargas Parciales (DP) utilizando tecnicas de medicion de Banda Ultra Ancha. El metodo desarrollado es no invasivo y consiste en la medicion de las DP en los conductores y conexiones a tierra de la pantalla de los cables principales de suministro de energia al motor, utilizando un sensor de campo cercano (bobina Rogowski, tipo gancho) cuyo ancho de banda de medicion es de 2 a 40 MHz. Las senales medidas por el sensor son electronicamente procesadas para ampliar su duracion, digitalizadas y enviadas a un detector digital de Descargas Parciales convencional. El sistema de deteccion de DP en Banda Ultra Ancha despliega la medicion en un patron de DP tipo frecuencia de repeticion de Pulso-Carga-Angulo de fase (N-Q-?). Se presentan los resultados obtenidos de la evaluacion en linea de trece motores de 2500 C.P. a 13.8 kV, instalados y operando en una

  10. 77 FR 58830 - State Program Requirements; Application To Administer Partial National Pollutant Discharge...

    Science.gov (United States)

    2012-09-24

    .... ODAFF does not have jurisdiction over storm water discharges associated with industrial activity (as defined at 40 CFR 122.26(b)(14)) at facilities whose primary industrial activity is storage of grain, feed... regulated by ODAFF that only incidentally store grain, feed, seed, fertilizer, and agriculture chemicals to...

  11. Development of a perpendicular vibration-induced electrical discharge machining process for fabrication of partially wavy inner structures

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ju Chul; Park, Sang Hu; Min, June Kee; Ha, Man Yeong; Shin, Bo Sung [Pusan National University, Busan (Korea, Republic of); Cho, Jong Rae [Korea Maritime University, Busan (Korea, Republic of)

    2016-05-15

    Heat transfer enhancement is an important issue in energy systems. To improve the efficiency of a cooling channel used inside injection molds, turbine blades, and high-temperature devices, channels with various shapes, such as wavy, elliptical, and twisted, have been studied. A cooling channel with a partially wavy inner structure has shown outstanding cooling performance despite a small increase in friction factor. However, generating a partially wavy inner structure inside a channel through conventional machining processes is not easy. To address this problem, we developed a new process called Perpendicular vibration-induced electrical discharge machining (PV-EDM). A specific electrode and one- and random-directional vibrating devices controlled by a pneumatic load were designed for the PV-EDM process. Experimental results showed that local shaping on the inner wall of a channel is possible, which confirmed the possibility of application of this process to actual industrial problems.

  12. Analysis of the partial discharge pulse propagation in the stat or winding of a synchronous machine

    Directory of Open Access Journals (Sweden)

    José Luis Oslinger-Gutiérrez

    2015-01-01

    Full Text Available En este artículo se presenta un estudio de la propagación de pu lsos de descarga parcial en el d evanado del estator de una máqu ina eléctrica sincrónica. El estudio se realizó inyecta ndo pulsos artificiales de descarg a parcial en el devanado del esta tor de una máquina sincrónica de polos salientes de 2.4 kV/210 kVA. Se encontró que la propagación de la señal de d escarga parcial se pre senta en dos modos: el modo lento, en el cual las bobinas actúan como una línea de transmisión, y el modo rápido, en el que el p ulso se propaga a través de las cabezas de bobina. El modo rápi do es debido a los acoplamientos capacitivos e induc tivos de las cabezas de bobina . En el modo lento, una señal de descarga parcial se manifiesta en los terminales del generador después de un tiempo de viaje que depende de la dista ncia recorrida por el pulso. Se e ncontró una fuerte correlación positiva entre el tiempo de llegada del modo lento y la l ongitud recorrida por el pulso en el modo lento. La resistenci a óhmica de DC entre el punto de inyección y el punto de medición fue utilizada para repre sentar la distancia recorrida por el pulso en el modo lento. Los acoplamientos capacitivos e inductivos de las cabezas de bobina ocasionan crosstalk entre fases. Como consecuencia, una señal de PD puede ser medid a en fases diferentes a la de origen. En el modo lento, las señales sufren atenuación e n su amplitud, debido a la dispe rsión de la señal y a la absorci ón de energía, a m edida que se propagan en el modo lento.

  13. Development of method for detecting signs deterioration in insulator of high-voltage motors. 2. Test Results of a new on-line partial discharge monitor for high-voltage motors in nuclear power stations

    International Nuclear Information System (INIS)

    Tochio, Atsushi; Kaneda, Yoshiharu; Urakawa, Nobuo

    2000-01-01

    For the purpose of early detection of deterioration of insulators in high-voltage motors which are widely utilized in nuclear power stations, a new on-line partial discharge (PD) monitor was developed and was tested for sixteen motors which were practically running in nuclear power stations. From the test results, it is seen that (1) good signal to noise ratio is obtained by adopting a two frequency correlation method, (2) a resistance temperature detector (RTD) in a motor has sufficient sensitivity to detect PD, (3) when RTD is not installed or is unable to use for this purpose, a radio frequency current transformer (RFCT) can be utilized, although its sensitivity is about 1/10 of that of the RTD monitor. Finally we found a good correlation between the results of this on-line method and the conventional off-line method in which the insulator resistance of a concerned motor was measured during its shut-down, and thereby we demonstrated that this method could be applicable to the on-line test of high-voltage motors in nuclear power stations. (author)

  14. Improved Method for PD-Quantification in Power Cables

    DEFF Research Database (Denmark)

    Holbøll, Joachim T.; Villefrance, Rasmus; Henriksen, Mogens

    1999-01-01

    n this paper, a method is described for improved quantification of partial discharges(PD) in power cables. The method is suitable for PD-detection and location systems in the MHz-range, where pulse attenuation and distortion along the cable cannot be neglected. The system transfer function...... was calculated and measured in order to form basis for magnitude calculation after each measurements. --- Limitations and capabilities of the method will be discussed and related to relevant field applications of high frequent PD-measurements. --- Methods for increased signal/noise ratio are easily implemented...

  15. Effect of different surface treatments and retainer designs on the retention of posterior Pd-Ag porcelain-fused-to-metal resin-bonded fixed partial dentures.

    Science.gov (United States)

    Chen, Xiwen; Zhang, Yixin; Zhou, Jinru; Chen, Chenfeng; Zhu, Zhimin; Li, Lei

    2018-02-01

    The aim of this study was to investigate the adhesive property of palladium-silver alloy (Pd-Ag) and the simulated clinical performance of Pd-Ag porcelain-fused-to-metal (PFM), resin-bonded, fixed partial dentures (RBFPDs). A total of 40 Pd-Ag discs (diameter=5 mm) were prepared and divided into the following four groups (n=10): a) No sandblasting, used as a control; and b, 50 µm; c, 110 µm; and d, 250 µm aluminum oxide (Al 2 O 3 ) particles, respectively. Another 50 discs were pre-sandblasted and divided into five groups (n=10) subjected to different treatments: e) Sandblasting, used as a control; f) silane; g) alloy primer; h) silica coating + silane and i) silica coating + alloy primer. All 90 discs were bonded to enamel with Panavia F 2.0 and then subjected to shear bond strength (SBS) testing. The fracture surfaces were examined by scanning electron microscopy. Next, 40 missing maxillary second premolar models were restored with one of the four following RBFPD designs (n=10): I) A premolar occlusal bar combined with molar double rests (MDR); II) both occlusal bars with a wing (OBB); III) a premolar occlusal bar combined with a molar dental band (MDB); and IV) two single rests adjacent to the edentulous space with a wing (SRB) used as a control. All specimens were aged with thermal cycling and mechanical loading. Subsequently, they were loaded until broken. The data were analyzed by one-way analysis of variance. Al 2 O 3 (250 µm) abrasion provided the highest SBS (P<0.05). The alloy primer and silica + silane exhibited increased SBS. Furthermore, fracture analysis revealed that the failure mode varied among the different treatments. Whereas MDB exhibited the highest retention (P<0.05), that of OBB was greater than that of MDR (P<0.05), and the control exhibited the lowest retention. Abrasion with Al 2 O 3 (250 µm) effectively increased the adhesive property of Pd-Ag. Additionally, treatment with the alloy primer and silica coating + silane was able to

  16. Partial discharge characteristics of polymer nanocomposite materials in electrical insulation: a review of sample preparation techniques, analysis methods, potential applications, and future trends.

    Science.gov (United States)

    Izzati, Wan Akmal; Arief, Yanuar Z; Adzis, Zuraimy; Shafanizam, Mohd

    2014-01-01

    Polymer nanocomposites have recently been attracting attention among researchers in electrical insulating applications from energy storage to power delivery. However, partial discharge has always been a predecessor to major faults and problems in this field. In addition, there is a lot more to explore, as neither the partial discharge characteristic in nanocomposites nor their electrical properties are clearly understood. By adding a small amount of weight percentage (wt%) of nanofillers, the physical, mechanical, and electrical properties of polymers can be greatly enhanced. For instance, nanofillers in nanocomposites such as silica (SiO2), alumina (Al2O3) and titania (TiO2) play a big role in providing a good approach to increasing the dielectric breakdown strength and partial discharge resistance of nanocomposites. Such polymer nanocomposites will be reviewed thoroughly in this paper, with the different experimental and analytical techniques used in previous studies. This paper also provides an academic review about partial discharge in polymer nanocomposites used as electrical insulating material from previous research, covering aspects of preparation, characteristics of the nanocomposite based on experimental works, application in power systems, methods and techniques of experiment and analysis, and future trends.

  17. A Novel High-Performance Beam-Supported Membrane Structure with Enhanced Design Flexibility for Partial Discharge Detection

    Directory of Open Access Journals (Sweden)

    Chenzhao Fu

    2017-03-01

    Full Text Available A novel beam-supported membrane (BSM structure for the fiber optic extrinsic Fabry-Perot interferometer (EFPI sensors showing an enhanced performance and an improved resistance to the temperature change was proposed for detecting partial discharges (PDs. The fundamental frequency, sensitivity, linear range, and flatness of the BSM structure were investigated by employing the finite element simulations. Compared with the intact membrane (IM structure commonly used by EFPI sensors, BSM structure provides extra geometrical parameters to define the fundamental frequency when the diameter of the whole membrane and its thickness is determined, resulting in an enhanced design flexibility of the sensor structure. According to the simulation results, it is noted that BSM structure not only shows a much higher sensitivity (increased by almost four times for some cases, and a wider working range of fundamental frequency to choose, but also an improved linear range, making the system development much easier. In addition, BSM structure presents a better flatness than its IM counterpart, providing an increased signal-to-noise ratio (SNR. A further improvement of performance is thought to be possible with a step-forward structural optimization. The BSM structure shows a great potential to design the EFPI sensors, as well as others for detecting the acoustic signals.

  18. Investigation of slot discharge on a 239 MVA hydro generator stator winding

    Energy Technology Data Exchange (ETDEWEB)

    Li, S.; Hong, W. [BC Hydro and Power Authority, Vancouver, BC (Canada)

    2009-07-01

    This paper discussed a slot discharge investigation conducted on a 239 MVA generator stator winding. The generator in which the winding was located had experienced core split distortion, stator winding phase-to-phase failures, winding failures during Hipot testing, and high partial discharge (PD) activity. The results of on-line PD testing data were evaluated. The stator winding was subjected to visual inspections, bar dissections, and failure mechanism analyses. Eleven winding bars were removed from the stator slots in order to assess groundwall insulation conditions and identify the cause of the slot discharge activity. It was determined that the root cause of the slot discharge was a loose, non-uniform bar in the slot. The vibrating bar caused the semi-conductive coating to wear out and degraded the armour tape. Results of the study demonstrated the importance of on-line PD monitoring for detecting slot PD activity. 4 refs., 3 tabs., 11 figs.

  19. Influence of N2 partial pressure on structural and microhardness properties of TiN/ZrN multilayers deposited by Ar/N2 vacuum arc discharge

    Science.gov (United States)

    Naddaf, M.; Abdallah, B.; Ahmad, M.; A-Kharroub, M.

    2016-08-01

    The influence of N2 partial pressure on structural, mechanical and wetting properties of multilayered TiN/ZrN thin films deposited on silicon substrates by vacuum arc discharge of (N2 + Ar) gas mixtures is investigated. X-ray diffraction (XRD) results show that the average texturing coefficient of (1 1 1) orientation and the grain size of both TiN and ZrN individual layers increase with increasing the N2 partial pressure. The Rutherford back scattering (RBS) measurements and analysis reveal that incorporation of the nitrogen in the film increases with increasing the N2 partial pressure and both TiN and ZrN individual layers have a nitrogen over-stoichiometry for N2 partial pressure ⩾50%. The change in the film micro-hardness is correlated to the changes in crystallographic texture, grain size, stoichiometry and the residual stress in the film as a function of the N2 partial pressure. In particular, stoichiometry of ZrN and TiN individual is found to play the vital role in determining the multilayer hardness. The multilayer film deposited at N2 partial pressure of 25% has the best stoichiometric ratio of both TiN and ZrN layers and the highest micro-hardness of about 32 GPa. In addition, water contact angle (WCA) measurements and analysis show a decrease in the work of adhesion on increasing the N2 partial pressure.

  20. Influence of N_2 partial pressure on structural and microhardness properties of TiN/ZrN multilayers deposited by Ar/N_2 vacuum arc discharge

    International Nuclear Information System (INIS)

    Naddaf, M.; Abdallah, B.; Ahmad, M.; A-Kharroub, M.

    2016-01-01

    The influence of N_2 partial pressure on structural, mechanical and wetting properties of multilayered TiN/ZrN thin films deposited on silicon substrates by vacuum arc discharge of (N_2 + Ar) gas mixtures is investigated. X-ray diffraction (XRD) results show that the average texturing coefficient of (1 1 1) orientation and the grain size of both TiN and ZrN individual layers increase with increasing the N_2 partial pressure. The Rutherford back scattering (RBS) measurements and analysis reveal that incorporation of the nitrogen in the film increases with increasing the N_2 partial pressure and both TiN and ZrN individual layers have a nitrogen over-stoichiometry for N_2 partial pressure ⩾50%. The change in the film micro-hardness is correlated to the changes in crystallographic texture, grain size, stoichiometry and the residual stress in the film as a function of the N_2 partial pressure. In particular, stoichiometry of ZrN and TiN individual is found to play the vital role in determining the multilayer hardness. The multilayer film deposited at N_2 partial pressure of 25% has the best stoichiometric ratio of both TiN and ZrN layers and the highest micro-hardness of about 32 GPa. In addition, water contact angle (WCA) measurements and analysis show a decrease in the work of adhesion on increasing the N_2 partial pressure.

  1. Characterization and electrocatalytic activity of Pt–M (M=Cu, Ag, and Pd) bimetallic nanoparticles synthesized by pulsed plasma discharge in water

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung-Min; Cho, Ah-Rong; Lee, Sang-Yul, E-mail: sylee@kau.ac.kr [Korea Aerospace University, Department of Materials Engineering, Center for Surface Technology and Applications (Korea, Republic of)

    2015-07-15

    The synthetic approach for electrocatalysts is one of the most important methods of determining electrocatalytic performance. In this work, we synthesized Pt and Pt–M (M=Cu, Ag, and Pd) bimetallic nanoparticles using a pulsed plasma discharge in water. A morphological investigation revealed that the as-synthesized Pt and Pt–M bimetallic nanoparticles constituted a nanochain network structure interconnected with primary nanoparticles of 4–6 nm in size, and the nanochains grew from the primary nanoparticles via the oriented attachment. The Z-contrast, EDX line scanning, and XRD analysis confirmed that the Pt was alloyed with M without elemental segregation or phase segregation. Furthermore, it was found that the composition difference was dependent on the electrode temperature determined by the power density and thermal parameters. The electrochemical results revealed that the electrocatalytic activity, stability, and durability of the Pt–Ag bimetallic nanoparticles were superior with respect to the methanol oxidation reaction, which could be attributed to the downshift of the d-band center via electronic modification.

  2. Power source for inactivation of micro-organisms with partial high voltage discharge in a continuous process

    NARCIS (Netherlands)

    Creyghton, Y.; Beurskens, R.; Fiala, A.; Haan, S.W.H. de

    2002-01-01

    An electrical discharge technology is investigated as non-thermal method for inactivation of microorganisms. Potential applications include treatment of drinking water (e.g. legionella) and liquid food pasteurization (e.g. fruit juices). A strong interest exists in mild food conservation processes

  3. Structural, mechanical, electrical and wetting properties of ZrNx films deposited by Ar/N2 vacuum arc discharge: Effect of nitrogen partial pressure

    Science.gov (United States)

    Abdallah, B.; Naddaf, M.; A-Kharroub, M.

    2013-03-01

    Non-stiochiometric zirconium nitride (ZrNx) thin films have been deposited on silicon substrates by vacuum arc discharge of (N2 + Ar) gas mixtures at different N2 partial pressure ratio. The microstructure, mechanical, electrical and wetting properties of these films are studied by means of X-ray diffraction (XRD), micro-Raman spectroscopy, Rutherford back scattering (RBS) technique, conventional micro-hardness testing, electrical resistivity, atomic force microscopy (AFM) and contact angle (CA) measurements. RBS results and analysis show that the (N/Zr) ratio in the film increases with increasing the N2 partial pressure. A ZrNx film with (Zr/N) ratio in the vicinity of stoichiometric ZrN is obtained at N2 partial pressure of 10%. XRD and Raman results indicate that all deposited films have strained cubic crystal phase of ZrN, regardless of the N2 partial pressure. On increasing the N2 partial pressure, the relative intensity of (1 1 1) orientation with respect to (2 0 0) orientation is seen to decrease. The effect of N2 partial pressure on micro-hardness and the resistivity of the deposited film is revealed and correlated to the alteration of grain size, crystallographic texture, stoichiometry and residual stress developed in the film. In particular, it is found that residual stress and nitrogen incorporation in the film play crucial role in the alteration of micro-hardness and resistivity respectively. In addition, CA and AFM results demonstrate that as N2 partial pressure increases, both the surface hydrophobicity and roughness of the deposited film increase, leading to a significant decrease in the film surface free energy (SFE).

  4. Validation of mathematical models for predicting the swirling flow and the vortex rope in a Francis turbine operated at partial discharge

    DEFF Research Database (Denmark)

    Kuibin, P.A.; Okulov, Valery; Susan-Resiga, R.F.

    2010-01-01

    recover all this information without actually computing the full three-dimensional unsteady flow in the hydraulic turbine. As a result, we provide valuable mathematical tools for assessing the turbine behaviour at off-design operating regimes in the early stages of runner design, with computational effort......The vortex rope in a hydro turbine draft tube is one the main and strong sources of pulsations in non-optimal modes of hydro turbine operation. We examine the case of a Francis turbine model operated at partial discharge, where a strong precessing vortex rope is developed in the discharge cone...... several orders of magnitude less than the current approaches of simulating the complex turbine flow....

  5. Influence of dielectric polarization upon PD transients: Use of hollow dielectric spheres

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson

    1997-01-01

    Hollow glass spheres have recently been employed to provide a reproducible source of partial discharges. The influence of the shell permittivity upon the PD transients is examined. It is shown that, relative to the non-shell situation, the magnitude of such transients may be increased or decrease......, depending on the ratio of the shell-to-bulk dielectric permittivities....

  6. Measuring system of partial discharges with optical links and interphase for PC; Sistema de medicion de descargas parciales con enlaces opticos e interfase para PC

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco Arteaga, Maria Jojutla Olimpia

    1999-07-01

    In this work a measuring system of partial discharges based on the traditional electrical detection technique is presented, but that unlike the existing systems it uses an optical link of communication. On one hand, the optical fiber avoids that the electromagnetic interference of the area affects the measurement and on the other hand, allows to make measurements online. With a personal computer and an application program the system is controlled, besides storing and displaying graphically the acquired data. As a result of this thesis the developed system obtains the magnitude and the phase of every partial discharge occurred during a time interval fixed or selected by the user, as well as the total number of discharges. In a graphical form it presents the magnitude and the phase of each discharge, in addition to the corresponding histogram of frequencies. [Spanish] En este trabajo se presenta un sistema de medicion de descargas parciales basado en la tecnica de deteccion electrica tradicional, pero que a diferencia de los sistemas existentes utiliza un enlace de comunicacion optico. Por un lado, la fibra optica evita que la interferencia electromagnetica del medio afecte la medicion y por otro, permite hacer mediciones en linea. Con una computadora personal y un programa de aplicacion se controla el sistema, ademas de almacenar y presentar graficamente la informacion adquirida. Como resultado de esta tesis el sistema desarrollado obtiene la magnitud y la fase de cada descarga parcial ocurrida durante un intervalo de tiempo fijo o seleccionado por el usuario, asi como el numero total de descargas. En forma grafica presenta la magnitud y la fase de cada descarga, ademas del histograma de frecuencias correspondiente.

  7. Discharge characteristics in inhomogeneous fields under air flow

    DEFF Research Database (Denmark)

    Vogel, Stephan; Holbøll, Joachim

    2017-01-01

    the frequency and magnitude of partial discharges in the vicinity of the electrode due to an increased rate of space charge removal around the tip of the needle and in the gap. The positive polarity shows higher dependency on air flow compared to the negative polarity. It is shown that positive breakdown......This research investigates the impact of high velocity air flow on Partial Discharge (PD) patterns generated in strongly inhomogeneous fields. In the laboratory, a needle plane electrode configuration was exposed to a high electrical DC-field and a laminar air flow up to 22 ms. The needle...

  8. PD-pulse characteristics in rotating machine insulation

    DEFF Research Database (Denmark)

    Holbøll, Joachim; Henriksen, Mogens; Jensen, A

    1994-01-01

    In this paper results are presented from investigations on partial discharges (PD) in insulation systems, resembling the stator insulation in high voltage rotating machines. A model, simulating a stator winding in a slot, has been developed, consisting of simple rotating machine insulation test...... bars with epoxy/mica insulation, mounted between steel sheets forming a dot, in order to investigate the fundamental behaviour of PD in insulation defects in epoxy/mica insulation and the characteristics of the resulting electrical pulses. Stator slot couplers (SSC) were used to detect pulses coming...

  9. Angina - discharge

    Science.gov (United States)

    Chest pain - discharge; Stable angina - discharge; Chronic angina - discharge; Variant angina - discharge; Angina pectoris - discharge; Accelerating angina - discharge; New-onset angina - discharge; Angina-unstable - discharge; ...

  10. Detection of partial discharges in oil transformers with the aid of acoustic emission analysis; Detektion von Teilentladungen in Oeltransformatoren durch die Schallemissionsanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Loehr, M. [Physical Acoustics BV - Deutschland, Hamburg (Germany)

    2007-07-01

    Since the early eighties, acoustic emission analysis has been used for functional testing of transformers. Partial discharges of 150 pC and above are detected reliably. Transformers with oil/paper insulation as a rule are inspected during operation by analysis of the transformer oil at regular intervals or continuously. This integral method provides no information on the operating conditions causing partial discharge and no information on their location. This information gap may be closed by acoustic emission analysis, which will provide the key information required for selective planning of preventive measures. Physical Acoustics (PAC) tested several hundreds of transformers successfully for their operating performance (see also EPRI Project I.D. No. 051481). As a result, e.g., transformers can now be operated for a longer period of time below critical load. [German] Die Schallemissionsanalyse wird seit den fruehen 80-iger Jahren letzten Jahrhunderts von Transformator-Herstellern bei der Funktionspruefung eingesetzt. Hierbei werden Teilentladungen von 150 pC und mehr zuverlaessig detektiert. Oel-papierisolierte Transformatoren werden in der Regel waehrend des Betriebs durch eine Analyse des Transformator-Oels inspeziert. Die Oelanalyse kann in regelmaessigen Abstaenden oder dauerhaft erfolgen. Als integrales Verfahren bietet diese Methode keine Information zu den Betriebsbedingungen unter den Teilentladungen auftreten und gibt auch keine Information zum Ort deren Auftretens. Diese Informationsluecke kann durch den Einsatz einer Schallemissionspruefung (AT) geschlossen werden. Mit dem Messen der Schallemission durch am Trafokessel angebrachte Sensoren kann der Ort und der Zeitpunkt von Stoerungen festgestellt werden. Mit diesen Schluesselinformationen wird es moeglich, die weiteren notwendigen Massnahmen gezielt zu planen. Physical Acoustics (PAC) hat mehrere hunderte von Transformatoren erfolgreich auf ihr Betriebsverhalten untersucht (siehe auch EPRI-Projekt I

  11. 103Pd decay

    International Nuclear Information System (INIS)

    Belyavenko, V.S.; Borozenets, G.P.; Vishnevskij, I.N.; Zheltonozhskij, V.A.

    1986-01-01

    103 Pd decay in different chemical states has been investigated. The change of the partial half-life period equal to 0.67±0.15% has been detected. The γ-spectrum has been measured to a high precision. The new data have been obtained on population probabilities of 103 Rh excited states and the total energy of decay for 103 Pd has been determined to a high precision (543.0±0.8). The values of log ft have been determined

  12. Application of affinity propagation algorithm based on manifold distance for transformer PD pattern recognition

    Science.gov (United States)

    Wei, B. G.; Huo, K. X.; Yao, Z. F.; Lou, J.; Li, X. Y.

    2018-03-01

    It is one of the difficult problems encountered in the research of condition maintenance technology of transformers to recognize partial discharge (PD) pattern. According to the main physical characteristics of PD, three models of oil-paper insulation defects were set up in laboratory to study the PD of transformers, and phase resolved partial discharge (PRPD) was constructed. By using least square method, the grey-scale images of PRPD were constructed and features of each grey-scale image were 28 box dimensions and 28 information dimensions. Affinity propagation algorithm based on manifold distance (AP-MD) for transformers PD pattern recognition was established, and the data of box dimension and information dimension were clustered based on AP-MD. Study shows that clustering result of AP-MD is better than the results of affinity propagation (AP), k-means and fuzzy c-means algorithm (FCM). By choosing different k values of k-nearest neighbor, we find clustering accuracy of AP-MD falls when k value is larger or smaller, and the optimal k value depends on sample size.

  13. Basal cell carcinoma: PD-L1/PD-1 checkpoint expression and tumor regression after PD-1 blockade.

    Science.gov (United States)

    Lipson, Evan J; Lilo, Mohammed T; Ogurtsova, Aleksandra; Esandrio, Jessica; Xu, Haiying; Brothers, Patricia; Schollenberger, Megan; Sharfman, William H; Taube, Janis M

    2017-01-01

    Monoclonal antibodies that block immune regulatory proteins such as programmed death-1 (PD-1) have demonstrated remarkable efficacy in controlling the growth of multiple tumor types. Unresectable or metastatic basal cell carcinoma, however, has largely gone untested. Because PD-Ligand-1 (PD-L1) expression in other tumor types has been associated with response to anti-PD-1, we investigated the expression of PD-L1 and its association with PD-1 expression in the basal cell carcinoma tumor microenvironment. Among 40 basal cell carcinoma specimens, 9/40 (22%) demonstrated PD-L1 expression on tumor cells, and 33/40 (82%) demonstrated PD-L1 expression on tumor-infiltrating lymphocytes and associated macrophages. PD-L1 was observed in close geographic association to PD-1+ tumor infiltrating lymphocytes. Additionally, we present, here, the first report of an objective anti-tumor response to pembrolizumab (anti-PD-1) in a patient with metastatic PD-L1 (+) basal cell carcinoma, whose disease had previously progressed through hedgehog pathway-directed therapy. The patient remains in a partial response 14 months after initiation of therapy. Taken together, our findings provide a rationale for testing anti-PD-1 therapy in patients with advanced basal cell carcinoma, either as initial treatment or after acquired resistance to hedgehog pathway inhibition.

  14. The Influence of the Presence of Multiple Voids on the Discharge Patterns in Solid Epoxy Insulation

    DEFF Research Database (Denmark)

    Holbøll, Joachim T.; Henriksen, Mogens; Larsen, Esben

    1996-01-01

    In this paper, partial discharge test results from initial long term testing on samples which contain more voids, when exposed to a high electric stress will be presented. The influence on the discharge patterns, phase- and height-analyses, of such parameter as the number of voids and the void...... diameters will be given. A first evaluation/opinion of the impact this could have on the estimation of the insulation condition of electrical equipment, based on the identification of PD-patterns, will also be given....

  15. Influence of N{sub 2} partial pressure on structural and microhardness properties of TiN/ZrN multilayers deposited by Ar/N{sub 2} vacuum arc discharge

    Energy Technology Data Exchange (ETDEWEB)

    Naddaf, M., E-mail: ascientific24@aec.org.sy [Department of Molecular Biology and Biotechnology, Atomic Energy Commission of Syria (AECS), P.O. Box 6091, Damascus (Syrian Arab Republic); Abdallah, B. [Department of Physics, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic); Ahmad, M. [IBA Laboratory, Department of Chemistry, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic); A-Kharroub, M. [Department of Physics, Atomic Energy Commission of Syria, P.O. Box 6091, Damascus (Syrian Arab Republic)

    2016-08-15

    The influence of N{sub 2} partial pressure on structural, mechanical and wetting properties of multilayered TiN/ZrN thin films deposited on silicon substrates by vacuum arc discharge of (N{sub 2} + Ar) gas mixtures is investigated. X-ray diffraction (XRD) results show that the average texturing coefficient of (1 1 1) orientation and the grain size of both TiN and ZrN individual layers increase with increasing the N{sub 2} partial pressure. The Rutherford back scattering (RBS) measurements and analysis reveal that incorporation of the nitrogen in the film increases with increasing the N{sub 2} partial pressure and both TiN and ZrN individual layers have a nitrogen over-stoichiometry for N{sub 2} partial pressure ⩾50%. The change in the film micro-hardness is correlated to the changes in crystallographic texture, grain size, stoichiometry and the residual stress in the film as a function of the N{sub 2} partial pressure. In particular, stoichiometry of ZrN and TiN individual is found to play the vital role in determining the multilayer hardness. The multilayer film deposited at N{sub 2} partial pressure of 25% has the best stoichiometric ratio of both TiN and ZrN layers and the highest micro-hardness of about 32 GPa. In addition, water contact angle (WCA) measurements and analysis show a decrease in the work of adhesion on increasing the N{sub 2} partial pressure.

  16. PD Lab

    NARCIS (Netherlands)

    Bilow, Marcel; Entrop, Alexis Gerardus; Lichtenberg, Jos; Stoutjesdijk, Pieter

    2015-01-01

    PD Lab explores the applications of building sector related product development. PD lab investigates and tests digital production technologies like CNC milled wood connections. It will also act as a platform in its wider meaning to investigate the effects and influences of file to factory

  17. 基于听觉场景分析的局部放电降噪算法研究%A Study of Ambient Noise Cancellation Algorithm of Partial Discharge Using CASA

    Institute of Scientific and Technical Information of China (English)

    刘闻

    2016-01-01

    In this paper,based on the partial discharge test of the high pressure chamber of the subway,the factory area and other noise environment,the paper proposes a kind of CASA algorithm,which is indepen-dent of the type of noise and the partial discharge noise reduction based on the analysis of the auditory scene.The algorithm uses two channels to col ect the signal energy,the simulation of the test instrument to extract the intensity difference of different channel signals,as a basis to identify the signal and noise.Then,the acoustic masking effect is used to cover the noise,and the enhancement of the partial discharge signal is realized.%该文针对周围为地铁,厂区等噪声环境下的高压室进行超声波局部放电测试,提出一种与噪声的类型无关、基于听觉场景分析的局部放电降噪CASA算法。该算法利用两个通道采集到的信号能量的不同,模拟局放测试仪提取不同信道信号的强度差,以此为依据来辨别信号和噪声。然后利用声学掩蔽效应,对噪声进行掩蔽,实现局部放电信号的增强。

  18. An investigation of the Pd-Ag-Ru-Gd quaternary system phase diagram

    International Nuclear Information System (INIS)

    Zhang Kanghou; Xu Yun

    2005-01-01

    On the basis of the Ag-Pd-Gd, Ag-Ru-Gd and Pd-Ru-Gd ternary systems, the partial phase diagram of Pd-Ag-Ru-Gd (Gd 3 Gd and Ag 51 Gd 14 ; five two-phase regions: Pd(Ag) + (Ru), Pd(Ag) + Ag 51 Gd 14 (Ru) + Ag 51 Gd 14 , Pd(Ag) + Pd 3 Gd and (Ru) + Pd 3 Gd; three three-phase regions: Pd(Ag) + Pd 3 Gd + (Ru), Pd(Ag) + Ag 51 Gd 14 + (Ru) and (Ru) + Ag 51 Gd 14 + Pd 3 Gd; one four-phase region Pd(Ag) + (Ru) + Ag 51 Gd 14 + Pd 3 Gd. No new quaternary intermetallic phase has been found

  19. Pancreatitis - discharge

    Science.gov (United States)

    Chronic pancreatitis - discharge; Pancreatitis - chronic - discharge; Pancreatic insufficiency - discharge; Acute pancreatitis - discharge ... You were in the hospital because you have pancreatitis. This is a swelling of the pancreas. You ...

  20. PD Lab

    Directory of Open Access Journals (Sweden)

    Marcel Bilow

    2015-08-01

    Full Text Available PD Lab explores the applications of building sector related product development.  PD lab investigates and tests digital production technologies like CNC milled wood connections. It will also act as a platform in its wider meaning to investigate the effects and influences of file to factory production, to explore the potential in the field of sustainability, material use, logistics and the interaction of stakeholders within the chain of the building process.

  1. Heart pacemaker - discharge

    Science.gov (United States)

    Cardiac pacemaker implantation - discharge; Artificial pacemaker - discharge; Permanent pacemaker - discharge; Internal pacemaker - discharge; Cardiac resynchronization therapy - discharge; CRT - discharge; ...

  2. Nipple Discharge

    Science.gov (United States)

    ... any unexpected nipple discharge evaluated by a doctor. Nipple discharge in men under any circumstances could be a problem and needs further evaluation. One or both breasts may produce a nipple discharge, either spontaneously or when you squeeze your ...

  3. Fusion of 110Pd with 110Pd

    International Nuclear Information System (INIS)

    Morawek, W.

    1991-07-01

    In the framework of this thesis the excitation functions of the systems 110 Pd + 110 Pd and 110 Pd + 104 Ru could be measured. The evaporation-residual-nucleus cross sections is deviating from lighter systems dominated by channels, which arise from evaporation of α particles. In the reaction 110 Pd + 110 Pd no xn channels were observed. In comparison to other reactions qualitatively a strong fusion hindrance of this system is shown. (orig./HSI) [de

  4. Chaotic characteristics of corona discharges in atmospheric air

    International Nuclear Information System (INIS)

    Tan Xiangyu; Zhang Qiaogen; Wang Xiuhuan; Sun Fu; Zha Wei; Jia Zhijie

    2008-01-01

    A point-plane electrode system in atmospheric air is established to investigate the mechanism of the corona discharge. By using this system, the current pulses of the corona discharges under the 50 Hz ac voltage are measured using partial discharge (PD) measurement instrument and constitute the point-plane voltage-current (V-I) characteristic equation together with the voltage. Then, this paper constructs the nonlinear circuit model and differential equations of the system in an attempt to give the underlying dynamic mechanism based on the nonlinear V-I characteristics of the point-plane corona discharges. The results show that the chaotic phenomenon is found in the corona circuit by the experimental study and nonlinear dynamic analysis. The basic dynamic characteristics, including the Lyapunov exponent, the existence of the strange attractors, and the equilibrium points, are also found and analyzed in the development process of the corona circuit. Moreover, the time series of the corona current pulses obtained in the experiment is used to demonstrate the chaotic characteristics of the corona current based on the nonlinear dynamic circuit theory and the experimental basis. It is pointed out that the corona phenomenon is not a purely stochastic phenomenon but a short term deterministic chaotic activity

  5. Classification of PD sources in HV cables using neural networks and the LN-FDTD method

    Energy Technology Data Exchange (ETDEWEB)

    Barros, W.H.; Oliveira, R.M.; Sobrinho, C.L.; Leite, R.C. [Univ. Federal do Para, Para (Brazil). Dept. of Computational and Electrical Engineering

    2008-07-01

    Partial discharges can be generated by the presence of several defects, and are often the cause of failures in electrical equipment insulators. In this study, a local non-orthogonal finite difference time-domain method (LN-FDTD) was used to simulate the sources of partial discharges in a high voltage coaxial cable model. The artificial neural network (ANN) technique used a Marquandt-Levenberg training algorithm to detect and classify cable PD sources. A set of harmonics obtained from the difference between the registered signals in the time domain was used as part of the training procedure. A failure was inserted on an electrical cable in each simulation in order to obtain the correlated data. Input signals were injected using a voltage pulse represented by a Gaussian function. A total of 90 simulations were conducted to generate 360 data groups in order to consider 6 different types of failures. Results of the study showed that the method can be used to detect and classify partial discharges in cables. 12 refs., 21 figs.

  6. Atomic Structure of Au−Pd Bimetallic Alloyed Nanoparticles

    KAUST Repository

    Ding, Yong; Fan, Fengru; Tian, Zhongqun; Wang, Zhong Lin

    2010-01-01

    shell of the NPs was systematically investigated by high-resolution transmission electron microscopy. In the NPs coated with a single atomic layer of Pd, the strain between the surface Pd layer and the Au core is released by Shockley partial dislocations

  7. NIPPLE DISCHARGE

    Directory of Open Access Journals (Sweden)

    T. N. Bukharova

    2008-01-01

    Full Text Available According to the data available in the literature, as high as 50% of women have benign breast tumors frequently accompanied by nip- ple discharge. Nipple discharge may be serous, bloody, purulent, and colostric. The most common causes are breast abscess, injury, drugs, prolactinoma, intraductal pappiloma, ductal ectasia, intraductal cancer (not more than 10%.

  8. Ileostomy - discharge

    Science.gov (United States)

    ... dried fruits (such as raisins), mushrooms, chunky relishes, coconut, and some Chinese vegetables. Tips for when no ... ask your doctor Living with your ileostomy Low-fiber diet Small bowel resection - discharge Total colectomy or ...

  9. Application Research of the Sparse Representation of Eigenvector on the PD Positioning in the Transformer Oil

    Directory of Open Access Journals (Sweden)

    Qing Xie

    2016-01-01

    Full Text Available The partial discharge (PD detection of electrical equipment is important for the safe operation of power system. The ultrasonic signal generated by the PD in the oil is a broadband signal. However, most methods of the array signal processing are used for the narrowband signal at present, and the effect of some methods for processing wideband signals is not satisfactory. Therefore, it is necessary to find new broadband signal processing methods to improve detection ability of the PD source. In this paper, the direction of arrival (DOA estimation method based on sparse representation of eigenvector is proposed, and this method can further reduce the noise interference. Moreover, the simulation results show that this direction finding method is feasible for broadband signal and thus improve the following positioning accuracy of the three-array localization method. And experimental results verify that the direction finding method based on sparse representation of eigenvector is feasible for the ultrasonic array, which can achieve accurate estimation of direction of arrival and improve the following positioning accuracy. This can provide important guidance information for the equipment maintenance in the practical application.

  10. Atomic Structure of Au−Pd Bimetallic Alloyed Nanoparticles

    KAUST Repository

    Ding, Yong

    2010-09-08

    Using a two-step seed-mediated growth method, we synthesized bimetallic nanoparticles (NPs) having a gold octahedron core and a palladium epitaxial shell with controlled Pd-shell thickness. The mismatch-release mechanism between the Au core and Pd shell of the NPs was systematically investigated by high-resolution transmission electron microscopy. In the NPs coated with a single atomic layer of Pd, the strain between the surface Pd layer and the Au core is released by Shockley partial dislocations (SPDs) accompanied by the formation of stacking faults. For NPs coated with more Pd (>2 nm), the stacking faults still exist, but no SPDs are found. This may be due to the diffusion of Au atoms into the Pd shell layers to eliminate the SPDs. At the same time, a long-range ordered L11 AuPd alloy phase has been identified in the interface area, supporting the assumption of the diffusion of Au into Pd to release the interface mismatch. With increasing numbers of Pd shell layers, the shape of the Au-Pd NP changes, step by step, from truncated-octahedral to cubic. After the bimetallic NPs were annealed at 523 K for 10 min, the SPDs at the surface of the NPs coated with a single atomic layer of Pd disappeared due to diffusion of the Au atoms into the surface layer, while the stacking faults and the L11 Au-Pd alloyed structure remained. When the annealing temperature was increased to 800 K, electron diffraction patterns and diffraction contrast images revealed that the NPs became a uniform Au-Pd alloy, and most of the stacking faults disappeared as a result of the annealing. Even so, some clues still support the existence of the L11 phase, which suggests that the L11 phase is a stable, long-range ordered structure in Au-Pd bimetallic NPs. © 2010 American Chemical Society.

  11. Modelo de estado para el estudio de las descargas parciales en el aislamiento principal de las máquinas eléctricas rotatorias de gran potencia; Big Rotating Machines State Model for Partial Discharges Studies in Main Insulation

    Directory of Open Access Journals (Sweden)

    Santiago A Dorrbercker Drake

    2011-02-01

    Full Text Available Se presenta un modelo de estado que caracteriza la tensión de ignición de las descargas parciales (DP enel aislamiento principal de las máquinas eléctricas rotatorias de gran potencia (MERGP.  Los objetivos delmodelamiento se dirigieron en dos vertientes:  la primera a conocer el comportamiento del menor nivel detensión que produce DP y la segunda destinada al comportamiento del tamaño de las cavidades, en lasque puede aparecer DP, atendiendo al nivel instantáneo de la tensión de corriente alterna (CA aplicada alas mismas. El presente trabajo se propone, proveer de una herramienta capaz de modelar el comportamientode algunos parámetros característicos de las DP en el aislamiento principal de las MERGP, cuando elaislamiento principal es sometido a diferentes condiciones de trabajo.  This paper describes a state model for PD inception voltage in main insulation of big rotating machines(BRM.  Intends of the present paper were:  to show the behaviour of PD inception voltage under differentfactors; and to know the relationships between the size of cavities and the instantaneous value of ACapplied voltage to the insulation. The objective of this paper is offer a computational tool able to model theperformance of some PD characteristic parameters when main insulation is under operation conditions.

  12. Interfacial processes in the Pd/a-Ge:H system

    Science.gov (United States)

    Edelman, F.; Cytermann, C.; Brener, R.; Eizenberg, M.; Weil, R.; Beyer, W.

    1993-06-01

    The kinetics of phase transformation has been studied in a two-layer structure of Pd/a-Ge:H after vacuum annealing at temperatures from 180 to 500°C. The a-Ge:H was deposited at 250°C on both c-Si and cleaved NaCl substrates in an RF glow discharge from a GeH 4/H 2 mixture. It was found that, similarly to the Pd/c-Ge and the Pd/a-Ge (e-gun deposited) systems, in the case of 0.15-0.2 μm Pd/0.6-1.0 μm a-Ge:H interfacial germanides formed first through the production of Pd 2Ge (plus a small amount of PdGe), and then PdGe was produced. The growth of both compounds was found to be diffusion-controlled. The nonreacted a-Ge:H layer beneath the germanide overlayer crystallized at 400-500°C. A reverse sequence of germanides formation was revealed in the case of 50 nm Pd/30 nm a-Ge:H, studied by in situ heat treatment in the TEM utilizing non-supported samples. The first germanide detected was PdGe and then, as a result of PdGe and Ge reaction or the PdGe decomposition, Pd 2Ge formed. The temperature dependence of the incubation time before the first ˜ 10 nm PdGe grains formed, followed an Arrhenius curve with an activation energy of 1.45 eV.

  13. Partial scram incident in FBTR

    International Nuclear Information System (INIS)

    Usha, S.; Pillai, C.P.; Muralikrishna, G.

    1989-01-01

    Evaluation of a partial scram incident occurred at the Fast Breeder Test Reactor at Kalpakkam was carried out. Based on the observations of the experiments it was ascertained that the nonpersistant order was due to superimposed noise component on the channel that was close to the threshold and had resulted in intermittent supply to electro-magnetic (EM) coils. Owing to a larger discharge time and a smaller charge time, the EM coils got progressively discharged. It was confirmed that during the incident, partial scram took place since the charging and discharging patterns of the EM coils are dissimilar and EM coils of rods A, E and F had discharged faster than others for noise component of a particular duty cycle. However, nonlatching of scram order was because of the fact that noise pulse duration was less than latching time. (author)

  14. Discharge Dialogue

    DEFF Research Database (Denmark)

    Horsbøl, Anders

    2012-01-01

    For several years, efforts have been made to strengthen collaboration between health professionals with different specializations and to improve patient transition from hospital to home (care). In the Danish health care system, these efforts have concentrated on cancer and heart diseases, whereas...... coordinator, employed at the hospital, is supposed to anticipate discharge and serve as mediator between the hospital and the municipal home care system. Drawing on methods from discourse and interaction analysis, the paper studies the practice of the discharge coordinator in two encounters between patients...... how the home context provides different resources for identification of patient needs and mutual decision making....

  15. Angioplasty and stent - heart - discharge

    Science.gov (United States)

    Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...

  16. Radiological discharges

    International Nuclear Information System (INIS)

    Woodliffe, J.

    1990-01-01

    Current practice of North Sea States on the discharge and disposal of liquid radioactive wastes to the North Sea are based on the declaration issued at the Second International Conference on the Protection of the North Sea, known as the London Declaration. This has three main points the first of which emphasises the application of the Best Available Technology to protect the North Sea, the second provides a framework on which future controls on radioactive discharges should be based. The third identifies two parts of the framework; to take into account the recommendations of international organizations and that any repositories of radioactive waste which are built should not pollute the North Sea. This chapter looks at how the concensus based on the London Declaration is working, gauges the progress made in the implementation of the policy goal, identifies existing and future areas for concern and proposes ways of strengthening the control of radioactive discharges. The emphasis is on the United Kingdom practice and regulations for liquid wastes, most of which comes from the Sellafield Reprocessing Plant. (author)

  17. Time domain PD-detection vs. dielectric spectroscopy

    DEFF Research Database (Denmark)

    Holbøll, Joachim T.; Edin, Hans; Gäfvert, Uno

    1997-01-01

    A theoretically developed relationship between partial discharges and the response from a system for dielectric spectroscopy was experimentally confirmed. The losses caused by the discharges were highest at test voltages with low frequencies. At 0.1 Hz, tanδ tip-up at discharge inception was very...

  18. Microscopic degradation mechanism of polyimide film caused by surface discharge under bipolar continuous square impulse voltage

    International Nuclear Information System (INIS)

    Luo Yang; Wu Guang-Ning; Liu Ji-Wu; Peng Jia; Gao Guo-Qiang; Zhu Guang-Ya; Wang Peng; Cao Kai-Jiang

    2014-01-01

    Polyimide (PI) film is an important type of insulating material used in inverter-fed motors. Partial discharge (PD) under a sequence of high-frequency square impulses is one of the key factors that lead to premature failures in insulation systems of inverter-fed motors. In order to explore the damage mechanism of PI film caused by discharge, an aging system of surface discharge under bipolar continuous square impulse voltage (BCSIV) is designed based on the ASTM 2275 01 standard and the electrical aging tests of PI film samples are performed above the partial discharge inception voltage (PDIV). The chemical bonds of PI polymer chains are analyzed through Fourier transform infrared spectroscopy (FTIR) and the dielectric properties of unaged and aged PI samples are investigated by LCR testers HIOKI 3532-50. Finally, the micro-morphology and micro-structure changes of PI film samples are observed through scanning electron microscopy (SEM). The results show that the physical and chemical effects of discharge cut off the chemical bonds of PI polymer chains. The fractures of ether bond (C—O—C) and imide ring (C—N—C) on the backbone of a PI polymer chain leads to the decrease of molecular weight, which results in the degradation of PI polymers and the generation of new chemical groups and materials, like carboxylic acid, ketone, aldehydes, etc. The variation of microscopic structure of PI polymers can change the orientation ability of polarizable units when the samples are under an AC electric field, which would cause the dielectric constant ε to increase and dielectric loss tan δ to decrease. The SEM images show that the degradation path of PI film is initiated from the surface and then gradually extends to the interior with continuous aging. The injection charge could result in the PI macromolecular chain degradation and increase the trap density in the PI polymer bulk. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  19. A Fiber Optic PD Sensor Using a Balanced Sagnac Interferometer and an EDFA-Based DOP Tunable Fiber Ring Laser

    Science.gov (United States)

    Wang, Lutang; Fang, Nian; Wu, Chunxu; Qin, Haijuan; Huang, Zhaoming

    2014-01-01

    A novel fiber-optic acoustic sensor using an erbium-doped fiber amplifier (EDFA)-based fiber ring laser and a balanced Sagnac interferometer for acoustic sensing of the partial discharge (PD) in power transformers is proposed and demonstrated. As a technical background, an experimental investigation on how the variations of the fiber birefringence affect the sensor performances was carried out, and the results are discussed. The operation principles are described, and the relevant formulas are derived. The analytical results show that an EDFA-based fiber ring laser operating in chaotic mode can provide a degree of polarization (DOP) tunable light beam for effectively suppressing polarization fading noises. The balanced Sagnac interferometer can eliminate command intensity noises and enhance the signal-to-noise ratio (SNR). Furthermore, it inherently operates at the quadrature point of the response curve without any active stabilizations. Several experiments are conducted for evaluating the performances of the sensor system, as well as for investigating the ability of the detection of high-frequency acoustic emission signals. The experimental results demonstrate that the DOP of the laser beam can be continuously tuned from 0.2% to 100%, and the power fluctuation in the whole DOP tuning range is less than 0.05 dBm. A high-frequency response up to 300 kHz is reached, and the high sensing sensitivity for detections of weak corona discharges, as well as partial discharges also is verified. PMID:24824371

  20. Plot Description (PD)

    Science.gov (United States)

    Robert E. Keane

    2006-01-01

    The Plot Description (PD) form is used to describe general characteristics of the FIREMON macroplot to provide ecological context for data analyses. The PD data characterize the topographical setting, geographic reference point, general plant composition and cover, ground cover, fuels, and soils information. This method provides the general ecological data that can be...

  1. Hysterectomy - vaginal - discharge

    Science.gov (United States)

    Vaginal hysterectomy - discharge; Laparoscopically assisted vaginal hysterectomy - discharge; LAVH - discharge ... you were in the hospital, you had a vaginal hysterectomy. Your surgeon made a cut in your ...

  2. Partial Cancellation

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Partial Cancellation. Full Cancellation is desirable. But complexity requirements are enormous. 4000 tones, 100 Users billions of flops !!! Main Idea: Challenge: To determine which cross-talker to cancel on what “tone” for a given victim. Constraint: Total complexity is ...

  3. Lung surgery - discharge

    Science.gov (United States)

    ... Lung biopsy - discharge; Thoracoscopy - discharge; Video-assisted thoracoscopic surgery - discharge; VATS - discharge ... milk) for 2 weeks after video-assisted thoracoscopic surgery and 6 to 8 weeks after open surgery. ...

  4. Pediatric heart surgery - discharge

    Science.gov (United States)

    ... discharge; Heart valve surgery - children - discharge; Heart surgery - pediatric - discharge; Heart transplant - pediatric - discharge ... Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ed. Philadelphia, PA: Elsevier; 2016:chap 434. ...

  5. Plasma breakdown in a capacitively-coupled radiofrequency argon discharge

    Science.gov (United States)

    Smith, H. B.; Charles, C.; Boswell, R. W.

    1998-10-01

    Low pressure, capacitively-coupled rf discharges are widely used in research and commercial ventures. Understanding of the non-equilibrium processes which occur in these discharges during breakdown is of interest, both for industrial applications and for a deeper understanding of fundamental plasma behaviour. The voltage required to breakdown the discharge V_brk has long been known to be a strong function of the product of the neutral gas pressure and the electrode seperation (pd). This paper investigates the dependence of V_brk on pd in rf systems using experimental, computational and analytic techniques. Experimental measurements of V_brk are made for pressures in the range 1 -- 500 mTorr and electrode separations of 2 -- 20 cm. A Paschen-style curve for breakdown in rf systems is developed which has the minimum breakdown voltage at a much smaller pd value, and breakdown voltages which are significantly lower overall, than for Paschen curves obtained from dc discharges. The differences between the two systems are explained using a simple analytic model. A Particle-in-Cell simulation is used to investigate a similar pd range and examine the effect of the secondary emission coefficient on the rf breakdown curve, particularly at low pd values. Analytic curves are fitted to both experimental and simulation results.

  6. Partial processing

    International Nuclear Information System (INIS)

    1978-11-01

    This discussion paper considers the possibility of applying to the recycle of plutonium in thermal reactors a particular method of partial processing based on the PUREX process but named CIVEX to emphasise the differences. The CIVEX process is based primarily on the retention of short-lived fission products. The paper suggests: (1) the recycle of fission products with uranium and plutonium in thermal reactor fuel would be technically feasible; (2) it would, however, take ten years or more to develop the CIVEX process to the point where it could be launched on a commercial scale; (3) since the majority of spent fuel to be reprocessed this century will have been in storage for ten years or more, the recycling of short-lived fission products with the U-Pu would not provide an effective means of making refabrication fuel ''inaccessible'' because the radioactivity associated with the fission products would have decayed. There would therefore be no advantage in partial processing

  7. Partial gigantism

    Directory of Open Access Journals (Sweden)

    М.М. Karimova

    2017-05-01

    Full Text Available A girl with partial gigantism (the increased I and II fingers of the left foot is being examined. This condition is a rare and unresolved problem, as the definite reason of its development is not determined. Wait-and-see strategy is recommended, as well as correcting operations after closing of growth zones, and forming of data pool for generalization and development of schemes of drug and radial therapeutic methods.

  8. Physics of partially ionized plasmas

    CERN Document Server

    Krishan, Vinod

    2016-01-01

    Plasma is one of the four fundamental states of matter; the other three being solid, liquid and gas. Several components, such as molecular clouds, diffuse interstellar gas, the solar atmosphere, the Earth's ionosphere and laboratory plasmas, including fusion plasmas, constitute the partially ionized plasmas. This book discusses different aspects of partially ionized plasmas including multi-fluid description, equilibrium and types of waves. The discussion goes on to cover the reionization phase of the universe, along with a brief description of high discharge plasmas, tokomak plasmas and laser plasmas. Various elastic and inelastic collisions amongst the three particle species are also presented. In addition, the author demonstrates the novelty of partially ionized plasmas using many examples; for instance, in partially ionized plasma the magnetic induction is subjected to the ambipolar diffusion and the Hall effect, as well as the usual resistive dissipation. Also included is an observation of kinematic dynam...

  9. Photogenic partial seizures.

    Science.gov (United States)

    Hennessy, M J; Binnie, C D

    2000-01-01

    To establish the incidence and symptoms of partial seizures in a cohort of patients investigated on account of known sensitivity to intermittent photic stimulation and/or precipitation of seizures by environmental visual stimuli such as television (TV) screens or computer monitors. We report 43 consecutive patients with epilepsy, who had exhibited a significant EEG photoparoxysmal response or who had seizures precipitated by environmental visual stimuli and underwent detailed assessment of their photosensitivity in the EEG laboratory, during which all were questioned concerning their ictal symptoms. All patients were considered on clinical grounds to have an idiopathic epilepsy syndrome. Twenty-eight (65%) patients reported visually precipitated attacks occurring initially with maintained consciousness, in some instances evolving to a period of confusion or to a secondarily generalized seizure. Visual symptoms were most commonly reported and included positive symptoms such as coloured circles or spots, but also blindness and subjective symptoms such as "eyes going funny." Other symptoms described included nonspecific cephalic sensations, deja-vu, auditory hallucinations, nausea, and vomiting. No patient reported any clear spontaneous partial seizures, and there were no grounds for supposing that any had partial epilepsy excepting the ictal phenomenology of some or all of the visually induced attacks. These findings provide clinical support for the physiological studies that indicate that the trigger mechanism for human photosensitivity involves binocularly innervated cells located in the visual cortex. Thus the visual cortex is the seat of the primary epileptogenic process, and the photically triggered discharges and seizures may be regarded as partial with secondary generalization.

  10. Tennis elbow surgery - discharge

    Science.gov (United States)

    ... epicondylitis surgery - discharge; Lateral tendinosis surgery - discharge; Lateral tennis elbow surgery - discharge ... long as you are told. This helps ensure tennis elbow will not return. You may be prescribed a ...

  11. Ankle replacement - discharge

    Science.gov (United States)

    ... total - discharge; Total ankle arthroplasty - discharge; Endoprosthetic ankle replacement - discharge; Osteoarthritis - ankle ... You had an ankle replacement. Your surgeon removed and reshaped ... an artificial ankle joint. You received pain medicine and were ...

  12. Hip fracture - discharge

    Science.gov (United States)

    ... neck fracture repair - discharge; Trochanteric fracture repair - discharge; Hip pinning surgery - discharge ... in the hospital for surgery to repair a hip fracture, a break in the upper part of ...

  13. Asthma - child - discharge

    Science.gov (United States)

    Pediatric asthma - discharge; Wheezing - discharge; Reactive airway disease - discharge ... Your child has asthma , which causes the airways of the lungs to swell and narrow. In the hospital, the doctors and nurses helped ...

  14. Influence of expander components on the processes at the negative plates of lead-acid cells on high-rate partial-state-of-charge cycling. Part II. Effect of carbon additives on the processes of charge and discharge of negative plates

    Energy Technology Data Exchange (ETDEWEB)

    Pavlov, D.; Nikolov, P.; Rogachev, T. [Institute of Electrochemistry and Energy Systems, Bulgarian Academy of Sciences, Acad. Georgi Bonchev Street, bl. 10, Sofia 1113 (Bulgaria)

    2010-07-15

    Lead-acid batteries operated in the high-rate partial-state-of-charge (HRPSoC) duty rapidly lose capacity on cycling, because of sulfation of the negative plates. As the battery operates from a partially discharged state, the small PbSO{sub 4} crystals dissolve and precipitate onto the bigger crystals. The latter have low solubility and hence PbSO{sub 4} accumulates progressively in the negative plates causing capacity loss. In order to suppress this process, the rate of the charge process should be increased. In a previous publication of ours we have established that reduction of Pb{sup 2+} ions to Pb may proceed on the surface of both Pb and carbon black particles. Hence, the reversibility of the charge-discharge processes improves, which leads to improved cycle life performance of the batteries in the HRPSoC mode. However, not all carbon forms accelerate the charge processes. The present paper discusses the electrochemical properties of two groups of carbon blacks: Printex and active carbons. The influence of Vaniseprse A and BaSO{sub 4} (the other two components of the expander added to the negative plates) on the reversibility of the charge-discharge processes on the negative plates is also considered. It has been established that lignosulfonates are adsorbed onto the lead surface and retard charging of the battery. BaSO{sub 4} has the opposite effect, which improves the reversibility of the processes on cycling and hence prolongs battery life in the HRPSoC duty. It has been established that the cycle life of lead-acid cells depends on the type of carbon black or active carbon added to the negative plates. When the carbon particles are of nano-sizes (<180 nm), the HRPSoC cycle life is between 10,000 and 20,000 cycles. Lignosulfonates suppress this beneficial effect of carbon black and activated carbon additives to about 10,000 cycles. Cells with active carbons have the longest cycle life when they contain also BaSO{sub 4} but no lignosulfonate. A summary of

  15. Prostate brachytherapy - discharge

    Science.gov (United States)

    Implant therapy - prostate cancer - discharge; Radioactive seed placement - discharge ... You had a procedure called brachytherapy to treat prostate cancer. Your treatment lasted 30 minutes or more, ...

  16. Electronic Structure of Fe-Pd Alloys Studied by Using Photoemission Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Nahm, T-U. [Hanyang University, Seoul (Korea, Republic of)

    2017-07-15

    We investigated the electronic structure of Fe{sub x}Pd{sub 1−x} (x = 0.25, 0.5, and 0.75) alloys by measuring valence-band and core-level photoelectron spectra. The Fe 3d and Pd 4d partial spectral weights were determined by using the Cooper minimum phenomenon of the Pd 4d photoionization cross section. We found that the experimentally determined Fe partial spectral weight of Fe{sub 50}Pd{sub 50} alloy differ much from the band calculation results, and we could not observe a spectral structure due to the Pd 4d states mixed with the Fe 3d majority states at the binding energy of 0.9 eV. We suggest that a plausible explanation for these discrepancies should be the spin-dependent lifetime of the Fe 3d states.

  17. `Pd20Sn13' revisited: crystal structure of Pd6.69Sn4.31

    Directory of Open Access Journals (Sweden)

    Wilhelm Klein

    2015-07-01

    Full Text Available The crystal structure of the title compound was previously reported with composition `Pd20Sn13' [Sarah et al. (1981. Z. Metallkd, 72, 517–520]. For the original structure model, as determined from powder X-ray data, atomic coordinates from the isostructural compound Ni13Ga3Ge6 were transferred. The present structure determination, resulting in a composition Pd6.69Sn4.31, is based on single crystal X-ray data and includes anisotropic displacement parameters for all atoms as well as standard uncertainties for the atomic coordinates, leading to higher precision and accuracy for the structure model. Single crystals of the title compound were obtained via a solid-state reaction route, starting from the elements. The crystal structure can be derived from the AlB2 type of structure after removing one eighth of the atoms at the boron positions and shifting adjacent atoms in the same layer in the direction of the voids. One atomic site is partially occupied by both elements with a Pd:Sn ratio of 0.38 (3:0.62 (3. One Sn and three Pd atoms are located on special positions with site symmetry 2. (Wyckoff letter 3a and 3b.

  18. Diffusion of hydrogen in Pd-(Ce, Y, B) alloys

    International Nuclear Information System (INIS)

    Sakamoto, Y.; Kaneko, H.; Tsukahara, T.; Hirata, S.

    1987-01-01

    The study has been carried out to determine the diffusivity of hydrogen in Pd alloys containing Ce, Y and B in atom fractions up to θ/sub μ/ = 0.1 by an electrochemical permeation method, and to examine the lattice dilation effect on the diffusivity in these alloys. Ce and Y have been chosen because the solid solubility of both in Pd is about 13 at% in spite of the very large atomic size-factor difference between Pd and the solutes, and thus the expansion of the Pd lattice by Ce and Y is much larger than by Ag. Furthermore, it is of interest that the partial enthalpy of the dissolved hydrogen at infinite dilution ΔH 0 /sub H/ for Ce and Y is much smaller than for Pd. On the other hand, B atom also expands the Pd lattice in a way similar to Y, and sometimes B atoms may dissolve in the octahedral interstitial sites in the same way as hydrogen atoms

  19. Experimental Investigation on Propagation Characteristics of PD Radiated UHF Signal in Actual 252 kV GIS

    Directory of Open Access Journals (Sweden)

    Tianhui Li

    2017-07-01

    Full Text Available For partial discharge (PD diagnostics in gas insulated switchgears (GISs based on the ultra-high-frequency (UHF method, it is essential to study the attenuation characteristics of UHF signals so as to improve the application of the UHF technique. Currently, the performance of UHF has not been adequately considered in most experimental research, while the constructive conclusions about the installation and position of UHF sensors are relatively rare. In this research, by using a previously-designed broadband sensor, the output signal is detected and analyzed experimentally in a 252 kV GIS with L-shaped structure and disconnecting switch. Since the relative position of the sensor and the defect is usually fixed by prior research, three circumferential angle positions of the defect in cross section are performed. The results are studied by time, statistics and frequency analyses. This identifies that the discontinuity conductor of DS will lead to a rise of both the peak to peak value (Vpp and the transmission rate of the UHF signal. Then, the frequency analysis indicates that the reason for the distinction of signal amplitude and transmission rate is that the mode components of the PD signal are distinctively affected by the special structure of GIS. Finally, the optimal circumferential angle position of the UHF Sensor is given based on the comparison of transmission rates.

  20. Electronic structure of Pd42.5Ni7.5Cu30P20, an excellent bulk metallic glass former: Comparison to the Pd40Ni40P20 reference glass

    International Nuclear Information System (INIS)

    Hosokawa, S.; Sato, H.; Happo, N.; Mimura, K.; Tezuka, Y.; Ichitsubo, T.; Matsubara, E.; Nishiyama, N.

    2007-01-01

    In-house photoemission and inverse-photoemission spectra (PES and IPES) were measured on Pd 42.5 Ni 7.5 Cu 30 P 20 and Pd 40 Ni 40 P 20 bulk metallic glasses in order to clarify the origin of excellent glass-forming ability from the viewpoint of electronic structure. Minima are observed for both the metallic glasses at a slightly higher energy than the Fermi level. Incident photon-energy dependent PES spectra were obtained using synchrotron radiation and the Pd 4d partial density of states (DOS) was estimated from the PES data. Soft X-ray emission spectra were also measured near the Ni and Cu 2p 3/2 absorption edges to evaluate, respectively, the Ni and Cu 3d partial DOS in the valence band. The Pd 4d and the Ni and Cu 3d partials in the conduction band were obtained from X-ray absorption spectra around the Pd 3p 3/2 and Ni and Cu 2p 3/2 absorption edges, respectively. It was found that the Pd 4d partial DOS near the Fermi energy largely decreases and becomes localized by replacing the Ni atoms with the Cu atoms, which may be closely related to the excellent glass-forming ability of the Pd 42.5 Ni 7.5 Cu 30 P 20 bulk metallic glass due to a selective formation of Pd-P covalent bonds

  1. Estimating sediment discharge: Appendix D

    Science.gov (United States)

    Gray, John R.; Simões, Francisco J. M.

    2008-01-01

    Sediment-discharge measurements usually are available on a discrete or periodic basis. However, estimates of sediment transport often are needed for unmeasured periods, such as when daily or annual sediment-discharge values are sought, or when estimates of transport rates for unmeasured or hypothetical flows are required. Selected methods for estimating suspended-sediment, bed-load, bed- material-load, and total-load discharges have been presented in some detail elsewhere in this volume. The purposes of this contribution are to present some limitations and potential pitfalls associated with obtaining and using the requisite data and equations to estimate sediment discharges and to provide guidance for selecting appropriate estimating equations. Records of sediment discharge are derived from data collected with sufficient frequency to obtain reliable estimates for the computational interval and period. Most sediment- discharge records are computed at daily or annual intervals based on periodically collected data, although some partial records represent discrete or seasonal intervals such as those for flood periods. The method used to calculate sediment- discharge records is dependent on the types and frequency of available data. Records for suspended-sediment discharge computed by methods described by Porterfield (1972) are most prevalent, in part because measurement protocols and computational techniques are well established and because suspended sediment composes the bulk of sediment dis- charges for many rivers. Discharge records for bed load, total load, or in some cases bed-material load plus wash load are less common. Reliable estimation of sediment discharges presupposes that the data on which the estimates are based are comparable and reliable. Unfortunately, data describing a selected characteristic of sediment were not necessarily derived—collected, processed, analyzed, or interpreted—in a consistent manner. For example, bed-load data collected with

  2. Frequency Dependent PD-pulse Distortion in Rotating Machines

    DEFF Research Database (Denmark)

    Holbøll, Joachim T.; Henriksen, Mogens

    1996-01-01

    at the machine terminals. The results show a variation of the attenuation of the discharge pulses inside the machine of about 20 dB highest for pulses from the far end, i.e. the neutral point. The capability of exact localization of the discharges in the winding gives a correct measure of the range...... of the current transformer based detection method, when being applied to rotating machines. The results are discussed with regard to the practical application of PD detection systems on rotating machines, particularly considering aspects of range and applicability of systems in the HF ranges...

  3. Resolution in partially accomodative esotropia during occlusion treatment for amblyopia.

    Science.gov (United States)

    Koc, F; Ozal, H; Yasar, H; Firat, E

    2006-03-01

    To evaluate alignment changes in partially accommodative esotropia during occlusion treatment for amblyopia. Changes at the deviation angles of 63 partially accommodative esotropia patients, who had occlusion treatment for amblyopia, were evaluated retrospectively. Mean deviation angle at the start of therapy without glasses was 45 PD (10-90 PD) and became 27 PD (5-70 PD) after at least 2 months with glasses. During 12 (2-36) months of occlusion period, mean manifest deviation angle with glasses decreased to 11 PD (0-50) (P amblyopia resolved in 71.5% of the cases. After termination of amblyopia treatment 24 (38%) cases had surgery for the residual deviation but if we had planned surgery before amblyopia treatment, 81% of the patients would have had surgery. Should amblyopia be treated initially or should we operate first in patients with strabismus and amblyopia together? Our research suggests that we should not hurry to operate in high hypermetropic partially accommodative cases, which have amblyopia and a long-term history of strabismus. Initial amblyopia treatment in these cases allows time for resolution of the nonaccomodative component in strabismus and can significantly decrease the necessity for surgery.

  4. Influence of expander components on the processes at the negative plates of lead-acid cells on high-rate partial-state-of-charge cycling. Part I: Effect of lignosulfonates and BaSO{sub 4} on the processes of charge and discharge of negative plates

    Energy Technology Data Exchange (ETDEWEB)

    Pavlov, D.; Nikolov, P.; Rogachev, T. [Institute of Electrochemistry and Energy Systems, Bulgarian Academy of Sciences, Acad. Georgi Bonchev Street, bl. 10, Sofia 1113 (Bulgaria)

    2010-07-15

    This study investigates the influence of the organic expander component (Vanisperse A) and of BaSO{sub 4} on the performance of negative lead-acid battery plates on high-rate partial-state-of-charge (HRPSoC) cycling. Batteries operating in the HRPSoC mode should be classified as a separate type of lead-acid batteries. Hence, the additives to the negative plates should differ from the conventional expander composition. It has been established that lignosulfonates are adsorbed onto the lead surface and thus impede the charge processes, which results in impaired reversibility of the charge-discharge processes and hence shorter cycle life on HRPSoC operation, limited by sulfation of the negative plates. BaSO{sub 4} exerts the opposite effect: it improves the reversibility of the processes in the HRPSoC mode and hence prolongs the cycle life of the cells. The most pronounced effect of BaSO{sub 4} has been registered when it is added in concentration of 1.0 wt.% versus the leady oxide (LO) used for paste preparation. It has also been established that BaSO{sub 4} lowers the overpotential of PbSO{sub 4} nucleation. The results of the present investigation indicate that BaSO{sub 4} affects also the crystallization process of Pb during cell charging. Thus, BaSO{sub 4} eventually improves the performance characteristics of lead-acid cells on HRPSoC cycling. (author)

  5. Vessel Sewage Discharges

    Science.gov (United States)

    Vessel sewage discharges are regulated under Section 312 of the Clean Water Act, which is jointly implemented by the EPA and Coast Guard. This homepage links to information on marine sanitation devices and no discharge zones.

  6. Influence of hydrogen on the thermoelectric power of palladium alloyed with neighbouring elements: I. Pd/Ru/H and Pd/Rh/H alloys

    CERN Document Server

    Szafranski, A W

    2003-01-01

    Pd/Ru and Pd/Rh alloys have been loaded with hydrogen in high-pressure conditions. The resulting hydrogen contents were close to the stoichiometric composition, H/(Pd + Me) = 1. Lower hydrogen contents have been obtained by successive partial desorptions. The thermoelectric power and electrical resistance of one- and two-phase alloys have been measured simultaneously in the temperature range between 80 and 300 K. A Nordheim-Gorter type correlation of the two quantities has been observed in many cases and the partial thermopowers corresponding to electron-phonon scattering and lattice disorder could be determined. The observed anomalous behaviour of the total and partial thermopowers is attributed to virtual bound states of ruthenium or rhodium.

  7. Early discharge following birth

    DEFF Research Database (Denmark)

    Nilsson, Ingrid M. S.; Kronborg, Hanne; Knight, Christopher H.

    2017-01-01

    .26–0.48) and primiparous compared to multiparous had an OR of 0.22 (CI 0.17–0.29) for early discharge. Other predictors for early discharge were: no induction of labour, no epidural painkiller, bleeding less than 500 ml during delivery, higher gestational age, early expected discharge and positive breastfeeding experience...

  8. Heart attack - discharge

    Science.gov (United States)

    ... and lifestyle Cholesterol - drug treatment Controlling your high blood pressure Deep vein thrombosis - discharge Dietary fats explained Fast food tips Heart attack - discharge Heart attack - what to ask your doctor Heart bypass ... pacemaker - discharge High blood pressure - what to ask your doctor How to read ...

  9. Electrodeless discharge lamp is easily started, has high stability

    Science.gov (United States)

    Bell, W. E.; Bloom, A. L.

    1966-01-01

    Electrodeless discharge borosilicate glass lamp is used in various high-resolution optical systems. It is partially charged with krypton, contains small amounts of rubidium, and is enclosed in a hermetically sealed envelope that maintains the lamp at an optimum temperature during discharge. The lamp is quickly started by its excitation coil.

  10. GRACE-based estimates of water discharge over the Yellow River basin

    Directory of Open Access Journals (Sweden)

    Qiong Li

    2016-05-01

    Full Text Available As critical component of hydrologic cycle, basin discharge is a key issue for understanding the hydrological and climatologic related to water and energy cycles. Combining GRACE gravity field models with ET from GLDAS models and precipitation from GPCP, discharge of the Yellow River basin are estimated from the water balance equation. While comparing the results with discharge from GLDAS model and in situ measurements, the results reveal that discharge from Mosaic and CLM GLDAS model can partially represent the river discharge and the discharge estimation from water balance equation could reflect the discharge from precipitation over the Yellow River basin.

  11. Computational physics of electric discharges in gas flows

    CERN Document Server

    Surzhikov, Sergey T

    2012-01-01

    Gas discharges are of interest for many processes in mechanics, manufacturing, materials science and aerophysics. To understand the physics behind the phenomena is of key importance for the effective use and development of gas discharge devices. This worktreats methods of computational modeling of electrodischarge processes and dynamics of partially ionized gases. These methods are necessary to tackleproblems of physical mechanics, physics of gas discharges and aerophysics.Particular attention is given to a solution of two-dimensional problems of physical mechanics of glow discharges.The use o

  12. The role of destabilization of palladium hydride in the hydrogen uptake of Pd-containing activated carbons

    International Nuclear Information System (INIS)

    Bhat, V V; Contescu, C I; Gallego, N C

    2009-01-01

    This paper reports on differences in stability of Pd hydride phases in palladium particles with various degrees of contact with microporous carbon supports. A sample containing Pd embedded in activated carbon fibre (2 wt% Pd) was compared with commercial Pd nanoparticles deposited on microporous activated carbon (3 wt% Pd) and with support-free nanocrystalline palladium. The morphology of the materials was characterized by electron microscopy, and the phase transformations were analysed over a large range of hydrogen partial pressures (0.003-10 bar) and at several temperatures using in situ x-ray diffraction. The results were verified with volumetric hydrogen uptake measurements. Results indicate that higher degrees of Pd-carbon contacts for Pd particles embedded in a microporous carbon matrix induce efficient 'pumping' of hydrogen out of β- PdH x . It was also found that thermal cleaning of carbon surface groups prior to exposure to hydrogen further enhances the hydrogen pumping power of the microporous carbon support. In brief, this study highlights that the stability of β- PdH x phase supported on carbon depends on the degree of contact between Pd and carbon and on the nature of the carbon surface.

  13. [Co/Pd]4–Co–Pd–NiFe spring magnets with highly tunable and uniform magnetization tilt angles

    International Nuclear Information System (INIS)

    Anh Nguyen, T.N.; Benatmane, N.; Fallahi, V.; Fang, Yeyu; Mohseni, S.M.; Dumas, R.K.; Åkerman, Johan

    2012-01-01

    By varying the Pd thickness (t Pd ) from 0 to 8 nm in [Co/Pd] 4 /Co/Pd(t Pd )/NiFe exchange springs, we demonstrate (i) continuous tailoring of the exchange coupling between a [Co/Pd] 4 /Co layer with perpendicular anisotropy, and a NiFe layer with an in-plane easy axis, (ii) tuning of the NiFe out-of-plane magnetization angle from 20 ○ to 80 ○ , and (iii) an up to two-fold increase in the NiFe damping. The partial decoupling also results in a highly uniform NiFe magnetization. These properties make [Co/Pd] 4 /Co/Pd(t Pd )/NiFe spring magnets ideal candidates for use as tilted polarizers, by combining stable and well-defined spin directions of its carriers with a high degree of angular freedom. - Highlights: ► Continuous tailoring of the exchange coupling between a [Co/Pd] 4 /Co layer and a NiFe layer. ►Tuning of the NiFe out-of-plane magnetization angle from 20° to 80°. ►A highly uniform NiFe magnetization. ►An up to two-fold increase in the NiFe damping.

  14. Promotion Effect of Alkali Metal Hydroxides on Polymer-Stabilized Pd Nanoparticles for Selective Hydrogenation of C–C Triple Bonds in Alkynols

    OpenAIRE

    Nikoshvili, Linda Zh.; Bykov, Alexey V.; Khudyakova, Tatiana E.; Lagrange, Thomas; Héroguel, Florent; Luterbacher, Jeremy S.; Matveeva, Valentina G.; Sulman, Esther M.; Dyson, Paul J.; Kiwi-Minsker, Lioubov

    2017-01-01

    Postimpregnation of Pd nanoparticles (NPs) stabilized within hyper-cross-linked polystyrene with sodium or potassium hydroxides of optimal concentration was found to significantly increase the catalytic activity for the partial hydrogenation of the C–C triple bond in 2-methyl-3-butyn-2-ol at ambient hydrogen pressure. The alkali metal hydroxide accelerates the transformation of the residual Pd(II) salt into Pd(0) NPs and diminishes the reaction induction period. In addition, the selectivity t...

  15. Charge-exchange neutral hydrogen measurements in TFTR using Pd-MOS microsensors

    International Nuclear Information System (INIS)

    Bastasz, R.; Kilpatrick, S.J.; Ruzic, D.N.

    1991-06-01

    An array of Pd-metal-oxide semiconductor (Pd-MOS) diodes has been used to monitor the fluence and energy of charge-exchange neutral hydrogen isotopes striking the wall of the Tokamak Fusion Test Reactor (TFTR). The array was positioned 4 cm behind the graphite-tiled wall at the toroidal midplane and exposed to several hundred plasma discharges. Hydrogen isotopes striking the Pd-MOS diodes were detected by measuring the leakage current, which is affected by the presence of these species at the Pd/SiO 2 interface. It was found that the midplane flux strongly increased for neutral-beam heated plasmas and correlated with co-injected neutral beam power. The majority of the neutral flux was <50 eV in energy but its energy distribution extended to above 500 eV. 20 refs., 4 figs

  16. Glow discharging device

    International Nuclear Information System (INIS)

    Maeno, Katsuki; Kawasaki, Kozo; Hiratsuka, Hajime; Kawashima, Shuichi.

    1989-01-01

    In a thermonuclear device, etc. impurities adsorbed to inner walls of a vacuum vessel by glow discharge are released to clean the vacuum vessel for preventing intrusion of the impurities into plasmas. The object of the present invention is to minimize the capacity of a power source equipment for the glow discharge device to the least extent. That is, a stabilization resistance is connected in series between each of a plurality of anodes which are inserted and arranged at the inside of a vacuum vessel as a cathode and a power source respectively. The resistance value R is selected so as to satisfy the relation: R < (Vi - Vm)/Ii, in which Vi: glow discharge starting voltage, Vm: glow discharge keeping voltage, Ii: glow discharge starting current. Accordingly, if a voltage is applied from a power source to a plurality of anodes, scattering of electric discharge between the anodes can be suppressed and the effect of voltage drop during discharge by the stabilization resistance can be eliminated. As a result, it is possible to provide an economically advantageous glow discharge device with the capacity for the power source facility being to the least extent. (K.M.)

  17. Magnetotransport in Pd-rich PdFe alloys

    Czech Academy of Sciences Publication Activity Database

    Kudrnovský, Josef; Drchal, Václav; Turek, Ilja

    2013-01-01

    Roč. 26, č. 5 (2013), s. 1749-1752 ISSN 1557-1939 R&D Projects: GA ČR(CZ) GAP204/11/1228 Institutional support: RVO:68378271 ; RVO:68081723 Keywords : galvanomagnetic transport * Pd-rich PdFe * long-range order * effect of temperature * anisotropic magnetoresistance Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.930, year: 2013

  18. CO-AXIAL DISCHARGES

    Science.gov (United States)

    Luce, J.S.; Smith, L.P.

    1960-11-22

    A method and apparatus are given for producing coaxial arc discharges in an evacuated enclosure and within a strong, confining magnetic field. The arcs are maintained at a high potential difference. Electrons will diffuse to the more positive arc from the negative arc, and positive ions will diffuse from the more positive arc to the negative arc. Coaxial arc discharges have the advantage that ions which return to strike the positive arc discharge will lose no energy since they do not strike a solid wall or electrode. Those discharges are useful in confining an ionized plasma between the discharges, and have the advantage of preventing impurities from the walls of the enclosure from entering ihe plasma area because of the arc barrier set up bv the cylindrical outer arc.

  19. Anti-PD-L1 Treatment Induced Central Diabetes Insipidus.

    Science.gov (United States)

    Zhao, Chen; Tella, Sri Harsha; Del Rivero, Jaydira; Kommalapati, Anuhya; Ebenuwa, Ifechukwude; Gulley, James; Strauss, Julius; Brownell, Isaac

    2018-02-01

    Immune checkpoint inhibitors, including anti-programmed cell death protein 1 (PD-1), anti-programmed cell death protein ligand 1 (PD-L1), and anti-cytotoxic T-lymphocyte antigen 4 (anti-CTLA4) monoclonal antibodies, have been widely used in cancer treatment. They are known to cause immune-related adverse events (irAEs), which resemble autoimmune diseases. Anterior pituitary hypophysitis with secondary hypopituitarism is a frequently reported irAE, especially in patients receiving anti-CTLA4 treatment. In contrast, posterior pituitary involvement, such as central diabetes insipidus (DI), is relatively rare and is unreported in patients undergoing PD-1/PD-L1 blockade. We describe a case of a 73-year-old man with Merkel cell carcinoma who received the anti-PD-L1 monoclonal antibody avelumab and achieved partial response. The patient developed nocturia, polydipsia, and polyuria 3 months after starting avelumab. Further laboratory testing revealed central DI. Avelumab was held and he received desmopressin for the management of central DI. Within 6 weeks after discontinuation of avelumab, the patient's symptoms resolved and he was eventually taken off desmopressin. The patient remained off avelumab and there were no signs or symptoms of DI 2 months after the discontinuation of desmopressin. To our knowledge, this is the first report of central DI associated with anti-PD-L1 immunotherapy. The patient's endocrinopathy was successfully managed by holding treatment with the immune checkpoint inhibitor. This case highlights the importance of early screening and appropriate management of hormonal irAEs in subjects undergoing treatment with immune checkpoint inhibitors to minimize morbidity and mortality. Copyright © 2017 Endocrine Society

  20. Modelling electric discharge chemistry

    International Nuclear Information System (INIS)

    McFarlane, J.; Wren, J.C.

    1991-07-01

    The chemistry occurring in a electric discharge was modelled to predict how it would be influenced by discharge conditions. The discharge was characterized by a calculated Boltzmann electron-energy distribution, from which rate constants for electron-molecule processes in air were determined. These rate constants were used in a chemical kinetics calculation that also included reactions between neutral molecules, ions, free radicals and electronically excited species. The model describes how the discharge chemistry was influenced by humidity, electric field, electron number density, and concentrations of key reagents identified in the study. The use of an electric discharge to destroy airborne contaminant molecules was appraised, the targeted contaminants being CF 2 Cl 2 , HCN, and SO 2 . The modelling results indicate that an electric discharge should be able to remove HCN and CF 2 Cl 2 effectively, especially if the discharge conditions have been optimized. Effective destruction is achieved with a moderate electric field (over 1 x 10 -15 V.cm 2 ), a substantial electron number density (over 1 x 10 12 cm -3 ), and the presence of H 2 0 in the process air. The residence time in the discharge was also shown to be important in contaminant destruction. An attempt was made to explain the results of the electric discharge abatement of SO 2 , a component of a simulated flue-gas mixture. Results from the model indicate that the discharge parameters that increase the concentration of hydroxyl radical also increase the rate of decomposition of SO 2 . An objective of the study was to explain the apparent enhancement of SO 2 destruction by the presence of a small amount of NO 2 . It was thought that a likely explanation would be the stabilization of HOSO 2 , an important intermediate in the oxidation of SO 2 by NO 2 . (49 figs., 14 tabs., 75 refs.)

  1. Efficient Catalytic Reduction of Hexavalent Chromium With Pd-decorated Carbon Nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Dang; Choi, Hyun Chul [Chonnam National University, Gwangju (Korea, Republic of)

    2016-05-15

    Heavy metal pollution is currently a serious environmental issue. Chromium (Cr) and chromium compounds are commonly found in wastewater discharged by various industries such as wood preservation, leather tanning, electroplating, metal finishing, and the production of chemicals. Pd nanoparticles can easily be introduced into CNTs by performing DCC-activated amidation. Our TEM and XRD results indicate that well-dispersed metallic Pd nanoparticles are anchored on the surface of the amidated CNTs. The XPS results suggest that the Pd content of the sample is approximately 9.8 atomic %. In comparison with the commercial Pd catalyst, the prepared Pd-CNTs were demonstrated to exhibit good catalytic activity in the reduction of 4-NP by NaBH4. Moreover, the Pd-CNT catalyst can easily be separated by performing a simple filtration and reused over at least 10 cycles. This Pd-CNT catalyst is therefore believed to have significant potential for use as a reusable catalyst in the reduction of Cr(Vi)

  2. Numerical Modelling of Electrical Discharges

    International Nuclear Information System (INIS)

    Durán-Olivencia, F J; Pontiga, F; Castellanos, A

    2014-01-01

    The problem of the propagation of an electrical discharge between a spherical electrode and a plane has been solved by means of finite element methods (FEM) using a fluid approximation and assuming weak ionization and local equilibrium with the electric field. The numerical simulation of this type of problems presents the usual difficulties of convection-diffusion-reaction problems, in addition to those associated with the nonlinearities of the charged species velocities, the formation of steep gradients of the electric field and particle densities, and the coexistence of very different temporal scales. The effect of using different temporal discretizations for the numerical integration of the corresponding system of partial differential equations will be here investigated. In particular, the so-called θ-methods will be used, which allows to implement implicit, semi-explicit and fully explicit schemes in a simple way

  3. Central peaking of magnetized gas discharges

    International Nuclear Information System (INIS)

    Chen, Francis F.; Curreli, Davide

    2013-01-01

    Partially ionized gas discharges used in industry are often driven by radiofrequency (rf) power applied at the periphery of a cylinder. It is found that the plasma density n is usually flat or peaked on axis even if the skin depth of the rf field is thin compared with the chamber radius a. Previous attempts at explaining this did not account for the finite length of the discharge and the boundary conditions at the endplates. A simple 1D model is used to focus on the basic mechanism: the short-circuit effect. It is found that a strong electric field (E-field) scaled to electron temperature T e , drives the ions inward. The resulting density profile is peaked on axis and has a shape independent of pressure or discharge radius. This “universal” profile is not affected by a dc magnetic field (B-field) as long as the ion Larmor radius is larger than a

  4. Effects of additive Pd on the structures and electrochemical hydrogen storage properties of Mg{sub 67}Co{sub 33}-based composites or alloys with BCC phase

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yao; Zhuang, Xiangyang [School of Materials Science and Engineering, Southeast University, Nanjing 211189 (China); Zhu, Yunfeng [College of Materials Science and Engineering, Nanjing Tech University, 5 Xinmofan Road, Nanjing 210009 (China); Zhan, Leyu [School of Materials Science and Engineering, Southeast University, Nanjing 211189 (China); Pu, Zhenggan [College of Materials Science and Engineering, Nanjing Tech University, 5 Xinmofan Road, Nanjing 210009 (China); Wan, Neng [SEU-FEI Nano Pico Center, Key Laboratory of MEMS of Ministry of Education, School of Electronics Science and Engineering, Southeast University, Nanjing 210096 (China); Li, Liquan [College of Materials Science and Engineering, Nanjing Tech University, 5 Xinmofan Road, Nanjing 210009 (China)

    2015-02-15

    Highlights: • Additive Pd in Mg{sub 67}Co{sub 33} benefits to form a ternary BCC alloy. • Introducing 5.0 at.% Pd in Mg{sub 67}Co{sub 33} lifts the initial discharge capacity from 10 mAh/g to maximum 530 mAh/g. • Exchange current density was increased due to the homogeneously dispersed Pd. • Additive Pd slightly enhances the hydrogen diffusion coefficient of Mg-Co-Pd composites or alloys. - Abstract: Mg{sub 67}Co{sub 33} and Mg{sub 67}Co{sub 33}-Pd composites/alloys prepared by ball milling for 120 h possess nano-crystalline with body-centered cubic (BCC) structure, which was verified by high resolution transmission electron microscopy (HRTEM) and selected area electron diffraction (SAED) analyses. The introduced 5.0 at.% Pd significantly lifts the initial discharge capacity from 10 mAh g{sup -1} of Mg{sub 67}Co{sub 33} to maximum 530 mAh g{sup -1}. Pd also drives the Mg{sub 67}Co{sub 33}-Pd composite forming a full BCC alloy during ball milling. The distribution of Pd gradually becomes homogeneous with the augmentation of the ball milling time according to the analyses by scanning electron microscopy-energy dispersive spectrometer (SEM-EDS). Exchange current density increased with the milling time and can be ascribed to the homogeneously dispersion of Pd over the surface. The introduced Pd also enhances the hydrogen diffusion coefficient of the Mg{sub 67}Co{sub 33}-Pd composites/alloys.

  5. Partial tooth gear bearings

    Science.gov (United States)

    Vranish, John M. (Inventor)

    2010-01-01

    A partial gear bearing including an upper half, comprising peak partial teeth, and a lower, or bottom, half, comprising valley partial teeth. The upper half also has an integrated roller section between each of the peak partial teeth with a radius equal to the gear pitch radius of the radially outwardly extending peak partial teeth. Conversely, the lower half has an integrated roller section between each of the valley half teeth with a radius also equal to the gear pitch radius of the peak partial teeth. The valley partial teeth extend radially inwardly from its roller section. The peak and valley partial teeth are exactly out of phase with each other, as are the roller sections of the upper and lower halves. Essentially, the end roller bearing of the typical gear bearing has been integrated into the normal gear tooth pattern.

  6. CO-induced Pd segregation and the effect of subsurface Pd on CO adsorption on CuPd surfaces

    International Nuclear Information System (INIS)

    Padama, A A B; Villaos, R A B; Albia, J R; Diño, W A; Nakanishi, H; Kasai, H

    2017-01-01

    We report results of our study on the adsorption of CO on CuPd surfaces with bulk stoichiometric and nonstoichiometric layers using density functional theory (DFT). We found that the presence of Pd atoms in the subsurface layer promotes the adsorption of CO. We also observed CO-induced Pd segregation on the CuPd surface and we attribute this to the strong CO–Pd interaction. Lastly, we showed that the adsorption of CO promotes Pd–Pd interaction as compared to the pristine surface which promotes strong Cu–Pd interaction. These results indicate that CO adsorption on CuPd surfaces can be tuned by taking advantage of the CO-induced segregation and by considering the role of subsurface Pd atoms. (paper)

  7. Essays on partial retirement

    NARCIS (Netherlands)

    Kantarci, T.

    2012-01-01

    The five essays in this dissertation address a range of topics in the micro-economic literature on partial retirement. The focus is on the labor market behavior of older age groups. The essays examine the economic and non-economic determinants of partial retirement behavior, the effect of partial

  8. Discharge lamp technologies

    Science.gov (United States)

    Dakin, James

    1994-01-01

    This talk is an overview of discharge lamp technology commonly employed in general lighting, with emphasis on issues pertinent to lighting for plant growth. Since the audience is primarily from the plant growth community, and this begins the light source part of the program, we will start with a brief description of the discharge lamps. Challenges of economics and of thermal management make lamp efficiency a prime concern in controlled environment agriculture, so we will emphasize science considerations relating to discharge lamp efficiency. We will then look at the spectra and ratings of some representative lighting products, and conclude with a discussion of technological advances.

  9. Capacitor discharge engineering

    CERN Document Server

    Früngel, Frank B A

    1976-01-01

    High Speed Pulse Technology, Volume III: Capacitor Discharge Engineering covers the production and practical application of capacitor dischargers for the generation and utilization of high speed pulsed of energy in different forms. This nine-chapter volume discusses the principles of electric current, voltage, X-rays, gamma rays, heat, beams of electrons, neutrons and ions, magnetic fields, sound, and shock waves in gases and liquids. Considerable chapters consider the applications of capacitor discharges, such as impulse hardening of steel, ultrapulse welding of precision parts, X-ray flash t

  10. Predicting tile drainage discharge

    DEFF Research Database (Denmark)

    Iversen, Bo Vangsø; Kjærgaard, Charlotte; Petersen, Rasmus Jes

    used in the analysis. For the dynamic modelling, a simple linear reservoir model was used where different outlets in the model represented tile drain as well as groundwater discharge outputs. This modelling was based on daily measured tile drain discharge values. The statistical predictive model...... was based on a polynomial regression predicting yearly tile drain discharge values using site specific parameters such as soil type, catchment topography, etc. as predictors. Values of calibrated model parameters from the dynamic modelling were compared to the same site specific parameter as used...

  11. Independent Validation of the SEND-PD and Correlation with the MDS-UPDRS Part IA

    Directory of Open Access Journals (Sweden)

    Mayela Rodríguez-Violante

    2014-01-01

    Full Text Available Introduction. Neuropsychiatric symptoms in Parkinson’s disease can be assessed by the MDS-UPDRS part IA. The Scale for Evaluation of Neuropsychiatric Disorders in Parkinson’s disease (SEND-PD has been recently developed to assess the severity of some neuropsychiatric symptoms. The objective of this study is to compare the performance of the SEND-PD with the corresponding items of the MDS-UPDRS part IA. Methods. Patients with Parkinson’s disease were evaluated using the MDS-UPDRS and the SEND-PD by independent raters. Partial SEND-PD and neuropsychiatric MDS-UPDRS part IA were constructed with equivalent items for comparison. Results. A total of 260 consecutive patients were included. Overall, 61.2% of the patients did not report any psychotic symptom and 83.5% did not report any ICD symptom. On the other hand, 78.5% of the patients did report at least one symptom related to apathy, depression, or anxiety. The partial SEND-PD score was 2.9±3.1 (range from 0 to 16. The neuropsychiatric MDS-UPDRS part IA score was 2.9±3 (range from 0 to 14. The correlation coefficient between corresponding items ranged from 0.67 to 0.98 and between both summary indexes was rs=0.93 (all, P<0.001. Conclusion. A high association between equivalent items of the SEND-PD and the MDS-UPDRS was found.

  12. Theoretical and experimental identification of a plasma in a gaseous discharge between two parallel plates electrodes

    International Nuclear Information System (INIS)

    Delgado Aparicio Villaran, Luis Felipe; Chaname D, Julio

    1996-01-01

    This work allows a basic approach to the identification of a gaseous discharge plasma (of air, hydrogen, argon or any other gas) between two metallic electrodes separated by a variable distance 'd' in the range of 1 to 17 cm. The discharge zone identification (anodic and cathodic regions), the tabulation of the characteristic curves V (volts), versus vs I (m A), and V (Volts) versus pd (Torr x cm), as well the implementation of some electric probes, will characterize this plasma. (author)

  13. Electric discharge during electrosurgery.

    Science.gov (United States)

    Shashurin, Alexey; Scott, David; Zhuang, Taisen; Canady, Jerome; Beilis, Isak I; Keidar, Michael

    2015-04-16

    Electric discharge utilized for electrosurgery is studied by means of a recently developed method for the diagnostics of small-size atmospheric plasma objects based on Rayleigh scattering of microwaves on the plasma volume. Evolution of the plasma parameters in the near-electrode sheaths and in the positive column is measured and analyzed. It is found that the electrosurgical system produces a glow discharge of alternating current with strongly contracted positive column with current densities reaching 10(3) A/cm(2). The plasma electron density and electrical conductivities in the channel were found be 10(16) cm(-3) and (1-2) Ohm(-1) cm(-1), respectively. The discharge interrupts every instance when the discharge-driving AC voltage crosses zero and re-ignites again every next half-wave at the moment when the instant voltage exceeds the breakdown threshold.

  14. Vaginal delivery - discharge

    Science.gov (United States)

    Pregnancy - discharge after vaginal delivery ... You may have bleeding from your vagina for up to 6 weeks. Early on, you may pass some small clots when you first get up. Bleeding will slowly become ...

  15. Prostate radiation - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000399.htm Prostate radiation - discharge To use the sharing features on ... keeping or getting an erection may occur after prostate radiation therapy. You may not notice this problem ...

  16. Brain injury - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000163.htm Brain injury - discharge To use the sharing features on ... know was in the hospital for a serious brain injury. At home, it will take time for ...

  17. Brain aneurysm repair - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000123.htm Brain aneurysm repair - discharge To use the sharing features ... this page, please enable JavaScript. You had a brain aneurysm . An aneurysm is a weak area in ...

  18. Brain radiation - discharge

    Science.gov (United States)

    Radiation - brain - discharge; Cancer - brain radiation; Lymphoma - brain radiation; Leukemia - brain radiation ... Decadron) while you are getting radiation to the brain. It may make you hungrier, cause leg swelling ...

  19. Atrial fibrillation - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000237.htm Atrial fibrillation - discharge To use the sharing features on this ... have been in the hospital because you have atrial fibrillation . This condition occurs when your heart beats faster ...

  20. Pneumonia - adults - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000017.htm Pneumonia in adults - discharge To use the sharing features on this page, please enable JavaScript. You have pneumonia, which is an infection in your lungs. In ...

  1. Knee arthroscopy - discharge

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000199.htm Knee arthroscopy - discharge To use the sharing features on this ... surgery to treat problems in your knee (knee arthroscopy). You may have been checked for: Torn meniscus. ...

  2. Cosmetic breast surgery - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000273.htm Cosmetic breast surgery - discharge To use the sharing features on this page, please enable JavaScript. You had cosmetic breast surgery to change the size or shape ...

  3. Shoulder surgery - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000179.htm Shoulder surgery - discharge To use the sharing features on this page, please enable JavaScript. You had shoulder surgery to repair the tissues inside or around your ...

  4. Recurrent Partial Words

    Directory of Open Access Journals (Sweden)

    Francine Blanchet-Sadri

    2011-08-01

    Full Text Available Partial words are sequences over a finite alphabet that may contain wildcard symbols, called holes, which match or are compatible with all letters; partial words without holes are said to be full words (or simply words. Given an infinite partial word w, the number of distinct full words over the alphabet that are compatible with factors of w of length n, called subwords of w, refers to a measure of complexity of infinite partial words so-called subword complexity. This measure is of particular interest because we can construct partial words with subword complexities not achievable by full words. In this paper, we consider the notion of recurrence over infinite partial words, that is, we study whether all of the finite subwords of a given infinite partial word appear infinitely often, and we establish connections between subword complexity and recurrence in this more general framework.

  5. Electrochemical and structural characterization of carbon-supported Pt-Pd bimetallic electrocatalysts prepared by electroless deposition

    Energy Technology Data Exchange (ETDEWEB)

    Ohashi, Masato; Beard, Kevin D.; Ma Shuguo; Blom, Douglas A.; St-Pierre, Jean; Van Zee, John W. [Department of Chemical Engineering, University of South Carolina, Columbia, SC 29208 (United States); Monnier, John R., E-mail: monnier@cec.sc.ed [Department of Chemical Engineering, University of South Carolina, Columbia, SC 29208 (United States)

    2010-10-01

    Electrochemical and structural characteristics of various Pt-Pd/C bimetallic catalysts prepared by electroless deposition (ED) methods have been investigated. Structural analysis was conducted by X-ray diffraction spectroscopy, X-ray photoelectron spectroscopy, scanning transmission electron microscopy, and energy dispersive X-ray spectroscopy (EDS). Monometallic Pt or Pd particles were not detected by EDS, indicating the ED methodology formed only bimetallic particles. The size of the Pt-Pd bimetallic particles was smaller than those of a commercially available Pt/C catalyst. The morphology of the Pt on Pd/C catalysts was identified and corresponded to Pd particles partially encapsulated by Pt. The electrochemical characteristics of the lowest Pd loading catalyst (7.0% Pt on 0.5% Pd/C) for the oxygen reduction reaction (ORR) have been investigated by the rotating ring disk electrode technique. The electrochemical activity was equal or lower than the commercially available Pt/C catalyst; however, the amount of hydrogen peroxide observed at the ring was reduced by the Pd, suggesting that such a catalyst has the potential to decrease ionomer degradation in applications. The Pt on Pd/C catalysts also show a higher tolerance to ripening induced by potential cycling. Therefore, catalyst suitability cannot be judged solely by its initial performance; information related to specific degradation mechanisms is also needed for a more complete assessment.

  6. Discharges for lighting

    International Nuclear Information System (INIS)

    Stoffels, W W; Nimalasuriya, T; Flikweert, A J; Mulders, H C J

    2007-01-01

    The most common man-made discharge is a lamp. Even though lamps are often considered a mature technology, the discharge physics is often poorly understood. Two recent initiatives discussed here show that plasma research can help to make significant improvements. First we discuss color separation in metal halide lamps, which is a problem that prevents these highly efficient lamps from being used in more applications. Secondly a novel lamp concept is presented that may replace the current mercury based fluorescent lamps

  7. Synthesis of Pd and Rh metal nanoparticles in the interlayer space of organically modified montmorillonite

    International Nuclear Information System (INIS)

    Patel, Hasmukh A.; Bajaj, Hari C.; Jasra, Raksh Vir

    2008-01-01

    This study reports the synthesis of palladium and rhodium metal nanoparticles supported on montmorillonite (MMT) and partially organically modified MMT (POMM) using tetraamine palladium and hexaamine rhodium complex as precursor for palladium and rhodium respectively. The synthesized nanoparticles were characterized by powder X-ray diffraction PXRD and TEM. The PXRD study shows characteristic crystallographic planes for Pd and Rh metal and confirm the formation of metal nanoparticles in MMT and POMM. The TEM images reveal the effect of organic modification of MMT on decreasing particle size of Pd and Rh metal. The Pd and Rh metal nanoparticles are agglomerated in pristine MMT while nanoparticles are well dispersed in POMM. ICP-AES analysis was carried out to estimate quantitative amount of Pd and Rh metal in MMT and POMM

  8. Discharge lamp technologies

    Energy Technology Data Exchange (ETDEWEB)

    Dakin, J. [GE Lighting, Cleveland, OH (United States)

    1994-12-31

    This talk is an overview of discharge lamp technology commonly employed in general lighting, with emphasis on issues pertinent to lighting for plant growth. Since the audience is primarily from the plant growth community, and this begins the light source part of the program, we will start with a brief description of the discharge lamps. Challenges of economics and of thermal management make lamp efficiency a prime concern in controlled environment agriculture, so we will emphasize science considerations relating to discharge lamp efficiency. We will then look at the spectra and ratings of some representative lighting products, and conclude with a discussion of technological advance. A general overview of discharge lighting technology can be found in the book of Waymouth (1971). A recent review of low pressure lighting discharge science is found in Dakin (1991). The pioneering paper of Reiling (1964) provides a good introduction to metal halide discharges. Particularly relevant to lighting for plant growth, a recent and thorough treatment of high pressure Na lamps is found in the book by deGroot and vanVliet (1986). Broad practical aspects of lighting application are thoroughly covered in the IES Lighting Handbook edited by Kaufman (1984).

  9. Chaos in gas discharges

    International Nuclear Information System (INIS)

    Piel, A.

    1993-01-01

    Many gas discharges exhibit natural oscillations which undergo a transition from regular to chaotic behavior by changing an experimental parameter or by applying external modulation. Besides several isolated investigations, two classes of discharge phenomena have been studied in more detail: ionization waves in medium pressure discharges and potential relaxation oscillations in filament cathode discharges at very low pressure. The latter phenomenon will be discussed by comparing experimental results from different discharge arrangements with particle-in-cell simulations and with a model based on the van-der-Pol equation. The filament cathode discharge has two stable modes of operation: the low current anode-glow-mode and the high current temperature-limited-mode, which form the hysteresis curve in the I(U) characteristics. Close to the hysteresis point of the AGM periodic relaxation oscillations occur. The authors demonstrate that the AGM can be understood by ion production in the anode layer, stopping of ions by charge exchange, and trapping in the virtual cathode around the filament. The relaxation oscillations consist of a slow filling phase and a rapid phase that invokes formation of an unstable double-layer, current-spiking, and ion depletion from the cathodic plasma. The relaxation oscillations can be mode-locked by external modulation. Inside a mode-locked state, a period doubling cascade is observed at high modulation degree

  10. Molecular mechanism of PD-1/PD-L1 blockade via anti-PD-L1 antibodies atezolizumab and durvalumab.

    Science.gov (United States)

    Lee, Hyun Tae; Lee, Ju Yeon; Lim, Heejin; Lee, Sang Hyung; Moon, Yu Jeong; Pyo, Hyo Jeong; Ryu, Seong Eon; Shin, Woori; Heo, Yong-Seok

    2017-07-17

    In 2016 and 2017, monoclonal antibodies targeting PD-L1, including atezolizumab, durvalumab, and avelumab, were approved by the FDA for the treatment of multiple advanced cancers. And many other anti-PD-L1 antibodies are under clinical trials. Recently, the crystal structures of PD-L1 in complex with BMS-936559 and avelumab have been determined, revealing details of the antigen-antibody interactions. However, it is still unknown how atezolizumab and durvalumab specifically recognize PD-L1, although this is important for investigating novel binding sites on PD-L1 targeted by other therapeutic antibodies for the design and improvement of anti-PD-L1 agents. Here, we report the crystal structures of PD-L1 in complex with atezolizumab and durvalumab to elucidate the precise epitopes involved and the structural basis for PD-1/PD-L1 blockade by these antibodies. A comprehensive comparison of PD-L1 interactions with anti-PD-L1 antibodies provides a better understanding of the mechanism of PD-L1 blockade as well as new insights into the rational design of improved anti-PD-L1 therapeutics.

  11. Estimation of Medium Voltage Cable Parameters for PD Detection

    DEFF Research Database (Denmark)

    Villefrance, Rasmus; Holbøll, Joachim T.; Henriksen, Mogens

    1998-01-01

    Medium voltage cable characteristics have been determined with respect to the parameters having influence on the evaluation of results from PD-measurements on paper/oil and XLPE-cables. In particular, parameters essential for discharge quantification and location were measured. In order to relate...... and phase constants. A method to estimate this propagation constant, based on high frequency measurements, will be presented and will be applied to different cable types under different conditions. The influence of temperature and test voltage was investigated. The relevance of the results for cable...

  12. Separation of 103Pd from metal Rhodium by dry distillation

    International Nuclear Information System (INIS)

    Szuecs, Z.; Takacs, S.

    2009-01-01

    Complete text of publication follows. Introduction. The use of Auger emitters as potential radiopharmaceuticals is increasingly investigated. One such radionuclide of interest is 103m Rh. This can be produced from 103 Ru or from 103 Pd in an in vivo generator. It has been proven on theoretical considerations that use of 103 Pd/ 103m Rh in vivo generator will be successful in delivering 103 mRh to a target site when complexed to a tumor selective carrier. 103 Pd is widely used in internal radiotherapy with one of the production routes via the irradiation of Rh by protons in a cyclotron. The charged particle production of 103 Pd is the only way for no-carrier -added production of this radionuclide, which is required for use in nuclear medicine. However, the widely used separation technique to get 103 Pd from the target material (as well as recovery of the Rh) by wet chemistry is a very complicated, labour intensive and expensive procedure, resulting in low yields of 103 Pd and high amounts of radioactive waste. An alternative more efficient separation and production technology can be developed based on differential evaporation. The principle is the following: The produced 103 Pd 'contaminating' new element within the crystal structure of the Rh target can be forced to diffuse out from the deformed crystal lattice by heating up the target. In this process the 103 Pd accumulates on the surface of the target from where it can be evaporated. A prerequisite for this process is that the target metal (Rh) has a different partial pressure than the evaporated metal (Pd). The thick target yield is 6MBq/μ Ah and the activities of potential contaminating radioisotopes produced by side reaction are negligible, if the energy of the irradiating beam will be chosen precisely. The natural abundance of 116 Cd is 7,5%, it means that the price of the enriched material is reasonable. A potential cyclotron facility with α-beam was found at JINR, Dubna, Russia where the radiochemical

  13. Dialysis Modality and Readmission Following Hospital Discharge: A Population-Based Cohort Study.

    Science.gov (United States)

    Perl, Jeffrey; McArthur, Eric; Bell, Chaim; Garg, Amit X; Bargman, Joanne M; Chan, Christopher T; Harel, Shai; Li, Lihua; Jain, Arsh K; Nash, Danielle M; Harel, Ziv

    2017-07-01

    Readmissions following hospital discharge among maintenance dialysis patients are common, potentially modifiable, and costly. Compared with patients receiving in-center hemodialysis (HD), patients receiving peritoneal dialysis (PD) have fewer routine dialysis clinic encounters and as a result may be more susceptible to a hospital readmission following discharge. Population-based retrospective-cohort observational study. Patients treated with maintenance dialysis who were discharged following an acute-care hospitalization during January 1, 2003, to December 31, 2013, across 164 acute-care hospitals in Ontario, Canada. For those with multiple hospitalizations, we randomly selected a single hospitalization as the index hospitalization. Dialysis modality PD or in-center HD. Propensity scores were used to match each patient on PD therapy to 2 patients on in-center HD therapy to ensure that baseline indicators of health were similar between the 2 groups. All-cause 30-day readmission following the index hospital discharge. 28,026 dialysis patients were included in the study. 4,013 PD patients were matched to 8,026 in-center HD patients. Among the matched cohort, 30-day readmission rates were 7.1 (95% CI, 6.6-7.6) per 1,000 person-days for patients on PD therapy and 6.0 (95% CI, 5.7-6.3) per 1,000 person-days for patients on in-center HD therapy. The risk for a 30-day readmission among patients on PD therapy was higher compared with those on in-center HD therapy (adjusted HR, 1.19; 95% CI, 1.08-1.31). The primary results were consistent across several key prespecified subgroups. Lack of information for the frequency of nephrology physician encounters following discharge from the hospital in both the PD and in-center HD cohorts. Limited validation of International Classification of Diseases, Tenth Revision codes. The risk for 30-day readmission is higher for patients on home-based PD compared to in-center HD therapy. Interventions to improve transitions in care between the

  14. Investigations on afterglows of neon gas discharges

    International Nuclear Information System (INIS)

    Steenhuysen, L.W.G.

    1979-01-01

    Experimental and numerical investigations on afterglows of neon gas discharges are described. The investigated pressure range extends from 0.5 torr to 100 torr; the discharge currents lie between about 1 mA and 100 mA. The decay of the 1s atom densities has been determined experimentally as function of the time elapsed in the afterglow. From the measured decay of metastable 1s 5 atom densities at gas pressure 5 atoms as well as the coefficinets of atomic collisional transfer between the 1s 5 and 1s 4 level are determined. To obtain more insight in the mutual influences of the various loss and production processes of 1s atoms and charge carriers in the afterglow a numerical model has been formed. The behaviour of the afterglow radiation intensity has been measured on discharges with a gas pressure of 1, 10, 20, 50 and 100 torr and a discharge current of 22, 24 and 50 mA. From the results the recombination distribution fractions of the 1s levels are determined and the electron densities at the start of the afterglow of 20, 50 and 100 torr discharges. With the help of the selective excitation spectroscopy the coefficients of atomic transfer between the 2p levels have been measured in the afterglow of discharge with a gas pressure of 1, 10, 20, 50 and 100 torr and a discharge current of 22 mA. From these results and the measured intensities of the various spectral lines in the afterglow the partial recombination coefficients for the 2p levels are calculated. (Auth. )

  15. Alternative splice variants of the human PD-1 gene

    DEFF Research Database (Denmark)

    Nielsen, Christian; Ohm-Laursen, Line; Barington, Torben

    2005-01-01

    PD-1 is an immunoregulatory receptor expressed on the surface of activated T cells, B cells, and monocytes. We describe four alternatively spliced PD-1 mRNA transcripts (PD-1Deltaex2, PD-1Deltaex3, PD-1Deltaex2,3, and PD-1Deltaex2,3,4) in addition to the full length isoform. PD-1Deltaex2 and PD-1...... and flPD-1 upon activation suggests an important interplay between the putative soluble PD-1 and flPD-1 possibly involved in maintenance of peripheral self-tolerance and prevention of autoimmunity....

  16. Pd-catalyzed Z-selective semihydrogenation of alkynes: determining the type of active species

    NARCIS (Netherlands)

    Drost, R.M.; Rosar, V.; Marta, S.D.; Lutz, M.; Demitri, N.; Milani, B.; de Bruin, B.; Elsevier, C.J.

    2015-01-01

    A protocol was developed to distinguish between well-defined molecular and nanoparticle-based catalysts for the Pd-catalyzed semihydrogenation reaction of alkynes to Z-alkenes. The protocol applies quantitative partial poisoning and dynamic light scattering methods, which allow the institution of

  17. Pd-Catalyzed Z-Selective Semihydrogenation of Alkynes : Determining the Type of Active Species

    NARCIS (Netherlands)

    Drost, Ruben M.; Rosar, Vera; Marta, Silvia Dalla; Lutz, Martin; Demitri, Nicola; Milani, Barbara; De Bruin, Bas; Elsevier, Cornelis J.

    2015-01-01

    A protocol was developed to distinguish between well-defined molecular and nanoparticle-based catalysts for the Pd-catalyzed semihydrogenation reaction of alkynes to Z-alkenes. The protocol applies quantitative partial poisoning and dynamic light scattering methods, which allow the institution of

  18. Development of highly transparent Pd-coated Ag nanowire electrode for display and catalysis applications

    Energy Technology Data Exchange (ETDEWEB)

    Canlier, Ali, E-mail: ali.canlier@agu.edu.tr [Department of Materials Science and Nanotechnology Engineering, Abdullah Gul University, P.O. Box 38080, Kayseri (Turkey); Ucak, Umit Volkan, E-mail: sirvolkan@gmail.com [Department of Materials Science and Nanotechnology Engineering, Abdullah Gul University, P.O. Box 38080, Kayseri (Turkey); Graduate School of Energy, Environment, Water, and Sustainability (EEWS), Korea Advanced Institute of Science and Technology (KAIST), P.O. Box 305-701, Daejeon (Korea, Republic of); Usta, Hakan, E-mail: husta38@gmail.com [Department of Materials Science and Nanotechnology Engineering, Abdullah Gul University, P.O. Box 38080, Kayseri (Turkey); Cho, Changsoon, E-mail: cscho@kaist.ac.kr [Graduate School of Energy, Environment, Water, and Sustainability (EEWS), Korea Advanced Institute of Science and Technology (KAIST), P.O. Box 305-701, Daejeon (Korea, Republic of); Lee, Jung-Yong, E-mail: jungyong.lee@kaist.ac.kr [Graduate School of Energy, Environment, Water, and Sustainability (EEWS), Korea Advanced Institute of Science and Technology (KAIST), P.O. Box 305-701, Daejeon (Korea, Republic of); Sen, Unal, E-mail: senunal@gmail.com [Department of Mechanical Engineering, Abdullah Gul University, P.O. Box 38080, Kayseri (Turkey); Citir, Murat, E-mail: muratcitir@gmail.com [Department of Chemical Engineering, Abdullah Gul University, P.O. Box 38080, Kayseri (Turkey)

    2015-09-30

    Highlights: • Highly uniform thin-layer coating of Pd onto Ag nanowire surface was accomplished. • A transparent electrode of Pd-coated Ag nanowire was uniformly deposited on flexible substrate. • 95% of optical transmittance and 175 Ω/sq sheet resistance were obtained. • Extremely low haze of 1.9% and high oxidation stability proved an efficient transparent electrode. • This electrode can be used as Pd-catalyst for synthesis reactions and fuel cell electrode applications. - Abstract: Ag nanowire transparent electrode has excellent transmittance (90%) and sheet resistance (20 Ω/sq), yet there are slight drawbacks such as optical haze and chemical instability against aerial oxidation. Chemical stability of Ag nanowires needs to be improved in order for it to be suitable for electrode applications. In our recent article, we demonstrated that coating Ag nanowires with a thin layer of Au through galvanic exchange reactions enhances the chemical stability of Ag nanowire films highly and also helps to obtain lower haze. In this study, coating of a thin Pd layer has been applied successfully onto the surface of Ag nanowires. A mild Pd complex oxidant [Pd(en){sub 2}](NO{sub 3}){sub 2} was prepared in order to oxidize Ag atoms partially on the surface via galvanic displacement. The mild galvanic exchange allowed for a thin layer (1–2 nm) of Pd coating on the Ag nanowires with minimal truncation of the nanowire, where the average length and the diameter were 12.5 μm and 59 nm, respectively. The Pd-coated Ag nanowires were suspended in methanol and then electrostatically sprayed on flexible polycarbonate substrates. It has been revealed that average total transmittance remain around 95% within visible spectrum region (400–800 nm) whereas sheet resistance rises up to 175 Ω/sq. To the best of our knowledge, for the first time in the literature, Pd coating was employed on Ag nanowires in order to design transparent electrodes for high transparency and strong

  19. KSC-03PD-2322

    Science.gov (United States)

    2003-01-01

    KENNEDY SPACE CENTER, FLA. The STS-114 crew is welcomed to Hangar AF, Cape Canaveral Air Force Station, by Joseph Chaput, with United Space Alliance. The crew, from left, are Mission Specialist Soichi Noguchi, Commander Eileen Collins, Mission Specialist Stephen Robinson and (partially hidden) Pilot James Kelly. Noguchi is with the Japanese space agency NASDA. On the mission, the crew will carry the MultiPurpose Logistics Module (MPLM) Raffaello and External Stowage Platform 2 to the International Space Station. The MPLM will contain supplies and equipment. Another goal of the mission is to remove and replace a Control Moment Gyro. Launch date for mission STS-114 is under review. Hangar AF is the site where SRB Retrieval Ships return the spent solid rocket boosters after a Shuttle launch. The SRBs are lifted from the water and placed on rail cars to begin the disassembly and refurbishment process.

  20. Multipactor discharge apparatus

    International Nuclear Information System (INIS)

    1976-01-01

    The invention deals with a multipactor discharge apparatus which can be used for tuning microwave organs such as magnetron oscillators and other cavity resonators. This apparatus is suitable for delivering an improved tuning effect in a resonation organ wherefrom the working frequency must be set. This apparatus is equipped with two multipactor discharge electrodes set in a configuration such to that a net current flows from one electrode to another. These electrodes are parallel and flat. The apparatus can be used in magnetron devices as well for continuous waves as for impulses

  1. Red herring vaginal discharge.

    Science.gov (United States)

    Lee, Jun Hee; Pringle, Kirsty; Rajimwale, Ashok

    2013-09-18

    Labial hair tourniquet syndrome is a rare condition that can be easily misdiagnosed and ultimately lead to irreversible damage. An 11-year-old premenarche girl presented with a 5-day history of pain and swelling in the labia with associated vaginal discharge. The general practitioner treated her with clotrimazole without improvement. On examination, there was an oedematous swelling of the right labia with a proximal hair tourniquet. Local anaesthetic was applied and the hair removed with forceps. There was instant relief of pain and the discharge stopped within 24 h. The patient was sent home with a course of antibiotics.

  2. Travelling-wave-sustained discharges

    International Nuclear Information System (INIS)

    Schlueter, Hans; Shivarova, Antonia

    2007-01-01

    This review is on discharges maintained by travelling waves: new plasma sources, discovered in 1974 and considered as a prototype of the gas discharges according to their definition as nonlinear systems which unify in a self-consistent manner plasmas and fields. In the presentation here of the fluid-plasma models of the diffusion-controlled regime of the travelling-wave-sustained discharges (TWSDs), the basic features of the discharge maintenance-the discharge self-consistency and the electron heating in the high-frequency field-are stressed. Operation of stationary and pulsed discharges, discharge maintenance without and in external magnetic fields as well as discharge production in different gases (argon, helium, helium-argon gas mixtures and hydrogen) are covered. Modulation instability of diffusion-controlled discharges and discharge filamentation at higher gas pressures are also included in the review. Experimental findings which motivate aspects of the reported modelling are pointed out

  3. Discharges from nuclear power stations

    International Nuclear Information System (INIS)

    1991-02-01

    HM Inspectorate of Pollution commissioned, with authorising responsibilities in England and Wales, a study into the discharges of radioactive effluents from Nuclear Power Stations. The study considered arisings from nuclear power stations in Europe and the USA and the technologies to treat and control the radioactive discharges. This report contains details of the technologies used at many nuclear power stations to treat and control radioactive discharges and gives, where information was available, details of discharges and authorised discharge limits. (author)

  4. G6PD: The Test

    Science.gov (United States)

    ... a G6PD deficiency if a male inherits the single X chromosome with an altered gene. Since women have two X sex chromosomes, they inherit two ... deficiency. In addition, a mother may pass the single mutated gene to any male children. Rarely do women have two mutated gene copies ( homozygous ), which could ...

  5. Empowering Patients: PD in Healthcare

    DEFF Research Database (Denmark)

    Kensing, Finn; Strand, Dixi Louise; Bansler, Jørgen P.

    2004-01-01

    In this paper, we discuss PD issues and concerns in the context of a national initiative the purpose of which is to provide IT support for the communication and collaboration within a heterogeneous network of patients/citizens and health care professionals. We present the notion of patient empowe...

  6. Synergetic mechanism of methanol–steam reforming reaction in a catalytic reactor with electric discharges

    International Nuclear Information System (INIS)

    Kim, Taegyu; Jo, Sungkwon; Song, Young-Hoon; Lee, Dae Hoon

    2014-01-01

    Highlights: • Methanol–steam reforming was performed on Cu catalysts under an electric discharge. • Discharge had a synergetic effect on the catalytic reaction for methanol conversion. • Discharge lowered the temperature for catalyst activation or light off. • Discharge controlled the yield and selectivity of species in a reforming process. • Adsorption triggered by a discharge was a possible mechanism for a synergetic effect. - Abstract: Methanol–steam reforming was performed on Cu/ZnO/Al 2 O 3 catalysts under an electric discharge. The discharge occurred between the electrodes where the catalysts were packed. The electric discharge was characterized by the discharge voltage and electric power to generate the discharge. The existence of a discharge had a synergetic effect on the catalytic reaction for methanol conversion. The electric discharge provided modified reaction paths resulting in a lower temperature for catalyst activation or light off. The discharge partially controlled the yield and selectivity of species in a reforming process. The aspect of control was examined in view of the reaction kinetics. The possible mechanisms for the synergetic effect between the catalytic reaction and electric discharge on methanol–steam reforming were addressed. A discrete reaction path, particularly adsorption triggered by an electric discharge, was suggested to be the most likely mechanism for the synergetic effect. These results are expected to provide a guide for understanding the plasma–catalyst hybrid reaction

  7. Time-resolved QXAFS studies on the formation and dynamic behavior of the highly active Pd catalyst

    International Nuclear Information System (INIS)

    Okumura, Kazu

    2009-01-01

    The stepwise growth of Pd in USY zeolite was followed by in situ scanning quick X-ray absorption fine structure (QXAFS) spectroscopy involving repeated alternating exposures to H 2 and O 2 flows at room temperature. During the first reduction of 0.4 wt%-Pd/USY with 8% H 2 , Pd clusters of 13 atoms with a coordination number (CN) of 5.1 formed within 20 min in the supercage of USY. The growth followed first-order kinetics with respect to the concentration of Pd 2+ and the CN of Pd-Pd. The clusters were stable up to 443 K. The clusters were partially oxidized in less than 2 min on exposure to 8% O 2 , and then quickly reduced with 8% H 2 (second reduction) to afford larger Pd clusters of 26 atoms. The clusters continued to increase in size in a stepwise fashion on further alternate exposures to O 2 and H 2 . The finely dispersed Pd 0 species exhibited extremely high activity in the Suzuki-Miyaura coupling reactions when the o-xylene solution was activated with H 2 -bubbling. (author)

  8. PD-L1-specific T cells

    DEFF Research Database (Denmark)

    Ahmad, Shamaila Munir; Borch, Troels Holz; Hansen, Morten

    2016-01-01

    -specific T cells that recognize both PD-L1-expressing immune cells and malignant cells. Thus, PD-L1-specific T cells have the ability to modulate adaptive immune reactions by reacting to regulatory cells. Thus, utilization of PD-L1-derived T cell epitopes may represent an attractive vaccination strategy...... for targeting the tumor microenvironment and for boosting the clinical effects of additional anticancer immunotherapy. This review summarizes present information about PD-L1 as a T cell antigen, depicts the initial findings about the function of PD-L1-specific T cells in the adjustment of immune responses...

  9. Dual inhibition of STAT1 and STAT3 activation downregulates expression of PD-L1 in human breast cancer cells.

    Science.gov (United States)

    Sasidharan Nair, Varun; Toor, Salman M; Ali, Bassam R; Elkord, Eyad

    2018-05-02

    Breast cancer is the most commonly diagnosed cancer, and it is a leading cause of cancer-related deaths in females worldwide. Triple-negative breast cancer (TNBC) constitutes 15% of breast cancer and shows distinct metastasis profiles with poor prognosis. Strong PD-L1 expression has been observed in some tumors, supporting their escape from immune surveillance. Targeting PD-L1 could be a promising therapeutic approach in breast cancer patients. We investigated potential molecular mechanisms for constitutive expression of PD-L1 by inhibiting upstream STAT1 and STAT3 signals. PD-L1 expression in three breast cancer cell lines was measured using quantitative PCR and western blotting. Activation of STAT1 and STAT3 was blocked using pharmacological inhibitors and siRNA. The mechanism underlying the constitutive expression of PD-L1 was investigated using ChIP and co-immunoprecipitation assays. We found that individual inhibition of STAT1 and STAT3 activation partially downregulated PD-L1, while combined inhibition completely downregulated PD-L1 expression. Moreover, our results suggest that pSTAT1-pSTAT3 dimerize in cytosol and translocate to the nucleus, where they bind to PD-L1 promoter and induce PD-L1 expression. These findings provide a rationale for combined targeting of STAT1 and STAT3 for the development of immune-based cancer therapies for down regulation of PD-L1 expression.

  10. Hyperbolic partial differential equations

    CERN Document Server

    Witten, Matthew

    1986-01-01

    Hyperbolic Partial Differential Equations III is a refereed journal issue that explores the applications, theory, and/or applied methods related to hyperbolic partial differential equations, or problems arising out of hyperbolic partial differential equations, in any area of research. This journal issue is interested in all types of articles in terms of review, mini-monograph, standard study, or short communication. Some studies presented in this journal include discretization of ideal fluid dynamics in the Eulerian representation; a Riemann problem in gas dynamics with bifurcation; periodic M

  11. Successful removable partial dentures.

    Science.gov (United States)

    Lynch, Christopher D

    2012-03-01

    Removable partial dentures (RPDs) remain a mainstay of prosthodontic care for partially dentate patients. Appropriately designed, they can restore masticatory efficiency, improve aesthetics and speech, and help secure overall oral health. However, challenges remain in providing such treatments, including maintaining adequate plaque control, achieving adequate retention, and facilitating patient tolerance. The aim of this paper is to review the successful provision of RPDs. Removable partial dentures are a successful form of treatment for replacing missing teeth, and can be successfully provided with appropriate design and fabrication concepts in mind.

  12. Beginning partial differential equations

    CERN Document Server

    O'Neil, Peter V

    2011-01-01

    A rigorous, yet accessible, introduction to partial differential equations-updated in a valuable new edition Beginning Partial Differential Equations, Second Edition provides a comprehensive introduction to partial differential equations (PDEs) with a special focus on the significance of characteristics, solutions by Fourier series, integrals and transforms, properties and physical interpretations of solutions, and a transition to the modern function space approach to PDEs. With its breadth of coverage, this new edition continues to present a broad introduction to the field, while also addres

  13. Selective Hydrogenation of Acrolein Over Pd Model Catalysts: Temperature and Particle-Size Effects.

    Science.gov (United States)

    O'Brien, Casey P; Dostert, Karl-Heinz; Schauermann, Swetlana; Freund, Hans-Joachim

    2016-10-24

    The selectivity in the hydrogenation of acrolein over Fe 3 O 4 -supported Pd nanoparticles has been investigated as a function of nanoparticle size in the 220-270 K temperature range. While Pd(111) shows nearly 100 % selectivity towards the desired hydrogenation of the C=O bond to produce propenol, Pd nanoparticles were found to be much less selective towards this product. In situ detection of surface species by using IR-reflection absorption spectroscopy shows that the selectivity towards propenol critically depends on the formation of an oxopropyl spectator species. While an overlayer of oxopropyl species is effectively formed on Pd(111) turning the surface highly selective for propenol formation, this process is strongly hindered on Pd nanoparticles by acrolein decomposition resulting in CO formation. We show that the extent of acrolein decomposition can be tuned by varying the particle size and the reaction temperature. As a result, significant production of propenol is observed over 12 nm Pd nanoparticles at 250 K, while smaller (4 and 7 nm) nanoparticles did not produce propenol at any of the temperatures investigated. The possible origin of particle-size dependence of propenol formation is discussed. This work demonstrates that the selectivity in the hydrogenation of acrolein is controlled by the relative rates of acrolein partial hydrogenation to oxopropyl surface species and of acrolein decomposition, which has significant implications for rational catalyst design. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Active sites and mechanisms for H2O2 decomposition over Pd catalysts

    Science.gov (United States)

    Plauck, Anthony; Stangland, Eric E.; Dumesic, James A.; Mavrikakis, Manos

    2016-01-01

    A combination of periodic, self-consistent density functional theory (DFT-GGA-PW91) calculations, reaction kinetics experiments on a SiO2-supported Pd catalyst, and mean-field microkinetic modeling are used to probe key aspects of H2O2 decomposition on Pd in the absence of cofeeding H2. We conclude that both Pd(111) and OH-partially covered Pd(100) surfaces represent the nature of the active site for H2O2 decomposition on the supported Pd catalyst reasonably well. Furthermore, all reaction flux in the closed catalytic cycle is predicted to flow through an O–O bond scission step in either H2O2 or OOH, followed by rapid H-transfer steps to produce the H2O and O2 products. The barrier for O–O bond scission is sensitive to Pd surface structure and is concluded to be the central parameter governing H2O2 decomposition activity. PMID:27006504

  15. 151Eu nuclear resonant inelastic scattering of Eu3Pd20Ge6

    International Nuclear Information System (INIS)

    Tsutsui, S.; Yoda, Y.; Kobayashi, Y.; Higashitaniguchi, S.; Seto, M.; Kitagawa, J.; Takabatake, T.

    2010-01-01

    151 Eu nuclear resonant inelastic scattering of Eu 3 Pd 20 Ge 6 . The Eu partial phonon density of states (DOS) in Eu 3 Pd 20 Ge 6 are investigated using 151 Eu nuclear resonance inelastic scattering (NRIS). 151 Eu NRIS was carried out at BL09XU of SPring-8. Significant temperature dependence was found in the partial phonon DOS. Judging from the valence change at the Eu 4a site and the comparison with the ab initio calculation of Eu 3 Pd 20 Ge 6 , the change of the Eu DOS is caused by the electronic states. On the other hand, significant acoustic contribution was found even at the guest site of the Eu ones. In addition, slower average velocity than transverse sound velocity was obtained by Eu partial phonon DOS. Considering that heat is carried by the acoustic phonon in materials, the present results demonstrate that the moderate thermal insulation in Eu 3 Pd 20 Ge 6 is connected with the observation of slow average sound velocity at the Eu sites. (K.F.)

  16. Partial knee replacement - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100225.htm Partial knee replacement - series—Normal anatomy To use the sharing ... A.M. Editorial team. Related MedlinePlus Health Topics Knee Replacement A.D.A.M., Inc. is accredited ...

  17. Single neutron pick-up on {sup 104}Pd

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, M.R.D.; Andre, J.P.A.M. de; Borello-Lewin, T.; Horodynski-Matsushigue, L.B.; Duarte, J.L.M.; Rodrigues, C.L. [Universidade de Sao Paulo, SP (Brazil). Inst. de Fisica; Ukita, G.M. [Universidade de Santo Amaro, SP (Brazil). Faculdade de Psicologia

    2006-12-15

    Low-lying levels of {sup 103}Pd have been investigated through the (d,t) reaction on {sup 104}Pd, at an incident deuteron energy of 15.0 MeV. Outgoing particles were momentum analyzed by an Enge magnetic spectrograph and detected in nuclear emulsion plates, with an energy resolution of 8 keV. Previous (d,t) work suffered from a much worse resolution than that here achieved. A partial analysis of the data obtained is reported, referring to six out of the fourteen scattering angles for which data were obtained. Angular distributions associated with eight of the thirteen levels seen up to 1.1 MeV of excitation have been compared to DWBA one-neutron pick-up predictions. Both, the attributed excitation energy values and the transferred angular momenta are in excellent agreement with the results of other kind of experiments, as tabulated by the Nuclear Data Sheets. Some peculiar structure characteristics, associated with the yrast 5/2{sup +}, 3/2{sup +} and 7/2{sup +} states found in the Ru chain could be recognized also in {sup 103}Pd, pointing to the possibility of a more global understanding of this transitional mass region. (author)

  18. Single neutron pick-up on 104Pd

    International Nuclear Information System (INIS)

    Rodrigues, M.R.D.; Andre, J.P.A.M. de; Borello-Lewin, T.; Horodynski-Matsushigue, L.B.; Duarte, J.L.M.; Rodrigues, C.L.; Ukita, G.M.

    2006-01-01

    Low-lying levels of 103 Pd have been investigated through the (d,t) reaction on 104 Pd, at an incident deuteron energy of 15.0 MeV. Outgoing particles were momentum analyzed by an Enge magnetic spectrograph and detected in nuclear emulsion plates, with an energy resolution of 8 keV. Previous (d,t) work suffered from a much worse resolution than that here achieved. A partial analysis of the data obtained is reported, referring to six out of the fourteen scattering angles for which data were obtained. Angular distributions associated with eight of the thirteen levels seen up to 1.1 MeV of excitation have been compared to DWBA one-neutron pick-up predictions. Both, the attributed excitation energy values and the transferred angular momenta are in excellent agreement with the results of other kind of experiments, as tabulated by the Nuclear Data Sheets. Some peculiar structure characteristics, associated with the yrast 5/2 + , 3/2 + and 7/2 + states found in the Ru chain could be recognized also in 103 Pd, pointing to the possibility of a more global understanding of this transitional mass region. (author)

  19. Vessel Sewage Discharges: No-Discharge Zones (NDZs)

    Science.gov (United States)

    States may petition the EPA to establish areas, called no discharge zones (NDZs), where vessel sewage discharges are prohibited. This page describes how NDZs are designated, the types of designations, who enforces them, and how to comply.

  20. Beginning partial differential equations

    CERN Document Server

    O'Neil, Peter V

    2014-01-01

    A broad introduction to PDEs with an emphasis on specialized topics and applications occurring in a variety of fields Featuring a thoroughly revised presentation of topics, Beginning Partial Differential Equations, Third Edition provides a challenging, yet accessible,combination of techniques, applications, and introductory theory on the subjectof partial differential equations. The new edition offers nonstandard coverageon material including Burger's equation, the telegraph equation, damped wavemotion, and the use of characteristics to solve nonhomogeneous problems. The Third Edition is or

  1. Experimental Evaluation of Discharge Characteristics in Inhomogeneous Fields under Air Flow

    DEFF Research Database (Denmark)

    Vogel, Stephan; Holbøll, Joachim

    2018-01-01

    voltages and a laminar air flow up to 22 m/s. In the first setup, the gap was exposed to a variable DC potential of up to 100 kV in order to create space charges in the vicinity of the electrode. The impact of the air flow on partial discharges and the dynamic behavior of the space charges is evaluated...... by means of partial discharge measurement and ultraviolet photography. The results show that the air flow increases the frequency of partial discharges in the gap due to an increased rate of space charge removal in the high field area around the tip of the electrode. The partial discharge behavior shows...... higher dependency on air flow at positive tip polarity as compared to the negative polarity. In the second setup, the standard impulse voltage created by a multistage impulse voltage generator was superimposed to a DC voltage, which continuously created corona and space charges around the tip...

  2. Pulse electrical discharges in water and their applications

    International Nuclear Information System (INIS)

    Sunka, Pavel

    2001-01-01

    Partial electrical discharges in a water solution as a function of conductivity have been studied experimentally. Using needle-plate electrodes it has been demonstrated that the discharge evolves in two phases. During the first streamer-like phase, the discharge propagated with a velocity of 10 6 cm/s, while during the second arc-like phase the length of the discharge remained almost constant although the current still increased. Higher solution conductivity resulted in the generation of shorter channels, in larger discharge current, and in a higher plasma electron density. Degradation of phenol by the discharge has also been demonstrated. A special metallic electrode covered by a thin layer of porous ceramic has been developed and used for generation of a multichannel discharge. At comparable solution conductivity the ceramic-coated electrode produced plasma with very similar parameters as the needle-plate electrode configuration. Generation of strong focused shock waves by the multichannel discharge in a highly conductive solution has also been demonstrated

  3. Monitoring of lightning discharge

    International Nuclear Information System (INIS)

    Grigor'ev, V.A.

    2001-01-01

    The paper presents a brief description of a lightning discharge recording system developed at the NPO 'Monitoring Techniques' under the direction of V.M. Moskolenko (Moscow). The system provides information about dangerous environmental occurrences such as tornados and hurricanes, making the forecast of extreme situations possible, especially in the areas of dangerous industries and objects. The created automatic system can be useful in solving the tasks relating to nuclear test monitoring. (author)

  4. Underwater Ship Husbandry Discharges

    Science.gov (United States)

    2011-11-01

    which entered into force in September of 2008, prohibits the use of harmful organotins such as tributyltin ( TBT ) in AFCs used on international...States. The use of TBT AFCs is explicitly prohibited under the VGP, and vessels must remove such coatings or paint over them to prevent toxic ...to hull husbandry include (1) the discharge of toxic chemicals used as biocides in AFCs and (2) biofouling as a vector for aquatic nuisance species

  5. Radioactive wastes and discharges

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The guide sets out the radiation safety requirements and limits for the treatment of radioactive waste. They shall be observed when discharging radioactive substances into the atmosphere or sewer system, or when delivering solid, low-activity waste to a landfill site without a separate waste treatment plan. The guide does not apply to the radioactive waste resulting from the utilisation of nuclear energy or natural resources.

  6. Radioactive wastes and discharges

    International Nuclear Information System (INIS)

    2000-01-01

    The guide sets out the radiation safety requirements and limits for the treatment of radioactive waste. They shall be observed when discharging radioactive substances into the atmosphere or sewer system, or when delivering solid, low-activity waste to a landfill site without a separate waste treatment plan. The guide does not apply to the radioactive waste resulting from the utilisation of nuclear energy or natural resources

  7. Pd enhanced WC catalyst to promote heterogeneous methane combustion

    International Nuclear Information System (INIS)

    Terracciano, Anthony Carmine; De Oliveira, Samuel; Siddhanti, Deepti; Blair, Richard; Vasu, Subith S.; Orlovskaya, Nina

    2017-01-01

    Highlights: • Pd enhanced WC catalyst particles were synthesized via mechanochemical alloying. • Catalyst was characterized by XRD, XRF, SEM, and EDS. • Catalyst was deposited on porous ZrO_2 and evaluated in heterogeneous combustion. • During combustion temperature profiles and spectral emissions were collected. - Abstract: The efficiency of combustion for low cost heat production could be greatly enhanced if an active and low cost catalyst would be used to facilitate the chemical reactions occurring during combustor operation. Within this work an experimental study of palladium (Pd) enhanced tungsten carbide (WC) catalyst, synthesized via high energy ball milling and deposited by dip coating onto a magnesia partially stabilized zirconia (MgO-ZrO_2) porous matrix of 10 ppin was evaluated in heterogeneous methane combustion. The synthesized powder was characterized by X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM) coupled with Energy Dispersive Spectroscopy (EDS) analysis, as well as by X-ray Fluorescence (XRF); and the morphology of the deposited WC-Pd coating was also characterized using SEM and EDS. Performance evaluation of the heterogeneous combustor with WC-Pd coated MgO-ZrO_2 porous media was conducted at constant air flow rate and various equivalence ratios of methane/air gaseous mixtures, while monitoring axial temperature profiles within the combustion chamber using thermocouples, as well as thermal radiative and acoustic emissions from the combustor exhaust using an externally placed CCD camera and a microphone. It was found that there is a strong dependence of flame position and maximum temperature on equivalence ratio (φ) over the range of 0.47 ± 0.02 ⩽ φ ⩽ 0.75 ± 0.02. Additionally it was found that over the same equivalence ratio range, there is a characteristic 4 peak acoustic signature between 200 and 500 Hz. It was found that at higher equivalence ratios 0.51 ± 0.02 ⩽ φ ⩽ 0.75 ± 0.02 the performance of combustor

  8. Power partial-discard strategy to obtain improved performance for simulated moving bed chromatography.

    Science.gov (United States)

    Chung, Ji-Woo; Kim, Kyung-Min; Yoon, Tae-Ung; Kim, Seung-Ik; Jung, Tae-Sung; Han, Sang-Sup; Bae, Youn-Sang

    2017-12-22

    A novel power partial-discard (PPD) strategy was developed as a variant of the partial-discard (PD) operation to further improve the separation performance of the simulated moving bed (SMB) process. The PPD operation varied the flow rates of discard streams by introducing a new variable, the discard amount (DA) as well as varying the reported variable, discard length (DL), while the conventional PD used fixed discard flow rates. The PPD operations showed significantly improved purities in spite of losses in recoveries. Remarkably, the PPD operation could provide more enhanced purity for a given recovery or more enhanced recovery for a given purity than the PD operation. The two variables, DA and DL, in the PPD operation played a key role in achieving the desired purity and recovery. The PPD operations will be useful for attaining high-purity products with reasonable recoveries. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Human striatal recordings reveal abnormal discharge of projection neurons in Parkinson's disease.

    Science.gov (United States)

    Singh, Arun; Mewes, Klaus; Gross, Robert E; DeLong, Mahlon R; Obeso, José A; Papa, Stella M

    2016-08-23

    Circuitry models of Parkinson's disease (PD) are based on striatal dopamine loss and aberrant striatal inputs into the basal ganglia network. However, extrastriatal mechanisms have increasingly been the focus of attention, whereas the status of striatal discharges in the parkinsonian human brain remains conjectural. We now report the activity pattern of striatal projection neurons (SPNs) in patients with PD undergoing deep brain stimulation surgery, compared with patients with essential tremor (ET) and isolated dystonia (ID). The SPN activity in ET was very low (2.1 ± 0.1 Hz) and reminiscent of that found in normal animals. In contrast, SPNs in PD fired at much higher frequency (30.2 ± 1.2 Hz) and with abundant spike bursts. The difference between PD and ET was reproduced between 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine-treated and normal nonhuman primates. The SPN activity was also increased in ID, but to a lower level compared with the hyperactivity observed in PD. These results provide direct evidence that the striatum contributes significantly altered signals to the network in patients with PD.

  10. Plasma Discharge Process in a Pulsed Diaphragm Discharge System

    Science.gov (United States)

    Duan, Jianjin; Hu, Jue; Zhang, Chao; Wen, Yuanbin; Meng, Yuedong; Zhang, Chengxu

    2014-12-01

    As one of the most important steps in wastewater treatment, limited study on plasma discharge process is a key challenge in the development of plasma applications. In this study, we focus on the plasma discharge process of a pulsed diaphragm discharge system. According to the analysis, the pulsed diaphragm discharge proceeds in seven stages: (1) Joule heating and heat exchange stage; (2) nucleated site formation; (3) plasma generation (initiation of the breakdown stage); (4) avalanche growth and plasma expansion; (5) plasma contraction; (6) termination of the plasma discharge; and (7) heat exchange stage. From this analysis, a critical voltage criterion for breakdown is obtained. We anticipate this finding will provide guidance for a better application of plasma discharges, especially diaphragm plasma discharges.

  11. Compact Intracloud Discharges

    Energy Technology Data Exchange (ETDEWEB)

    Smith, David A. [Univ. of Colorado, Boulder, CO (United States)

    1998-11-01

    In November of 1993, mysterious signals recorded by a satellite-borne broadband VHF radio science experiment called Blackboard led to a completely unexpected discovery. Prior to launch of the ALEXIS satellite, it was thought that its secondary payload, Blackboard, would most often detect the radio emissions from lightning when its receiver was not overwhelmed by noise from narrowband communication carriers. Instead, the vast majority of events that triggered the instrument were isolated pairs of pulses that were one hundred times more energetic than normal thunderstorm electrical emissions. The events, which came to be known as TIPPs (for transionospheric pulse pairs), presented a true mystery to the geophysics community. At the time, it was not even known whether the events had natural or anthropogenic origins. After two and one half years of research into the unique signals, two ground-based receiver arrays in New Mexico first began to detect and record thunderstorm radio emissions that were consistent with the Blackboard observations. On two occasions, the ground-based systems and Blackboard even recorded emissions that were produced by the same exact events. From the ground based observations, it has been determined that TIPP events areproduced by brief, singular, isolated, intracloud electrical discharges that occur in intense regions of thunderstorms. These discharges have been dubbed CIDS, an acronym for compact intracloud discharges. During the summer of 1996, ground-based receiver arrays were used to record the electric field change signals and broadband HF emissions from hundreds of CIDS. Event timing that was accurate to within a few microseconds made possible the determination of source locations using methods of differential time of arrival. Ionospheric reflections of signals were recorded in addition to groundwave/line-of-sight signals and were used to determine accurate altitudes for the discharges. Twenty-four CIDS were recorded from three

  12. Partial differential equations

    CERN Document Server

    Evans, Lawrence C

    2010-01-01

    This text gives a comprehensive survey of modern techniques in the theoretical study of partial differential equations (PDEs) with particular emphasis on nonlinear equations. The exposition is divided into three parts: representation formulas for solutions; theory for linear partial differential equations; and theory for nonlinear partial differential equations. Included are complete treatments of the method of characteristics; energy methods within Sobolev spaces; regularity for second-order elliptic, parabolic, and hyperbolic equations; maximum principles; the multidimensional calculus of variations; viscosity solutions of Hamilton-Jacobi equations; shock waves and entropy criteria for conservation laws; and, much more.The author summarizes the relevant mathematics required to understand current research in PDEs, especially nonlinear PDEs. While he has reworked and simplified much of the classical theory (particularly the method of characteristics), he primarily emphasizes the modern interplay between funct...

  13. Discharging a DC bus capacitor of an electrical converter system

    Science.gov (United States)

    Kajouke, Lateef A; Perisic, Milun; Ransom, Ray M

    2014-10-14

    A system and method of discharging a bus capacitor of a bidirectional matrix converter of a vehicle are presented here. The method begins by electrically shorting the AC interface of the converter after an AC energy source is disconnected from the AC interface. The method continues by arranging a plurality of switching elements of a second energy conversion module into a discharge configuration to establish an electrical current path from a first terminal of an isolation module, through an inductive element, and to a second terminal of the isolation module. The method also modulates a plurality of switching elements of a first energy conversion module, while maintaining the discharge configuration of the second energy conversion module, to at least partially discharge a DC bus capacitor.

  14. Continuous pile discharging machine

    International Nuclear Information System (INIS)

    Smith, P.P.

    1976-01-01

    A device for discharging cartridges from tubes under fluid pressure includes a cylindrical housing adapted to be seated in a leak-tight manner on the end of one of the tubes, a chute depending from the cylindrical housing near the end seated on the end of the tube, a rotatable piston having a wrench on the forward end thereof disposed in the cylindrical housing and adapted to manipulate a plug in the end of the tube, and a telescopic hydraulic ram adapted to move the piston toward the plug. In addition the wrench contains a magnet which prevents inadvertent uncoupling of the wrench and the plug. 7 claims, 10 drawing figures

  15. Capacitive discharge exciplex lamps

    Energy Technology Data Exchange (ETDEWEB)

    Sosnin, E A; Erofeev, M V; Tarasenko, V F [High Current Electronics Institute, 2/3, Akademichesky Ave., Tomsk 634055 (Russian Federation)

    2005-09-07

    Simple-geometry exciplex lamps of a novel type excited by a capacitive discharge (CD-excilamps) have been investigated. An efficient radiation has been obtained on KrBr*, KrCl*, XeBr*, XeCl* molecules and I* atom. The highest values of efficiency of various working molecules are approximately 10-18%. The lifetime of the operating gas mixture in KrCl*, XeCl*, I* and XeBr* exciplex lamps excited by a CD is above 1000 h. Owing to the above-mentioned characteristics, the exciplex lamps excited by a CD are supposed to be very promising for various applications.

  16. Capacitive discharge exciplex lamps

    International Nuclear Information System (INIS)

    Sosnin, E A; Erofeev, M V; Tarasenko, V F

    2005-01-01

    Simple-geometry exciplex lamps of a novel type excited by a capacitive discharge (CD-excilamps) have been investigated. An efficient radiation has been obtained on KrBr*, KrCl*, XeBr*, XeCl* molecules and I* atom. The highest values of efficiency of various working molecules are approximately 10-18%. The lifetime of the operating gas mixture in KrCl*, XeCl*, I* and XeBr* exciplex lamps excited by a CD is above 1000 h. Owing to the above-mentioned characteristics, the exciplex lamps excited by a CD are supposed to be very promising for various applications

  17. Continuous pile discharging machine

    Science.gov (United States)

    Smith, Phillips P.

    1976-05-11

    A device for discharging cartridges from tubes under fluid pressure includes a cylindrical housing adapted to be seated in a leak-tight manner on the end of one of the tubes, a chute depending from the cylindrical housing near the end seated on the end of the tube, a rotatable piston having a wrench on the forward end thereof disposed in the cylindrical housing and adapted to manipulate a plug in the end of the tube, and a telescopic hydraulic ram adapted to move the piston toward the plug. In addition the wrench contains a magnet which prevents inadvertent uncoupling of the wrench and the plug.

  18. Optimization of partial search

    International Nuclear Information System (INIS)

    Korepin, Vladimir E

    2005-01-01

    A quantum Grover search algorithm can find a target item in a database faster than any classical algorithm. One can trade accuracy for speed and find a part of the database (a block) containing the target item even faster; this is partial search. A partial search algorithm was recently suggested by Grover and Radhakrishnan. Here we optimize it. Efficiency of the search algorithm is measured by the number of queries to the oracle. The author suggests a new version of the Grover-Radhakrishnan algorithm which uses a minimal number of such queries. The algorithm can run on the same hardware that is used for the usual Grover algorithm. (letter to the editor)

  19. PD-1/PD-L1 Inhibitors for Immuno-oncology: From Antibodies to Small Molecules.

    Science.gov (United States)

    Geng, Qiaohong; Jiao, Peifu; Jin, Peng; Su, Gaoxing; Dong, Jinlong; Yan, Bing

    2018-02-12

    The recent regulatory approvals of immune checkpoint protein inhibitors, such as ipilimumab, pembrolizumab, nivolumab, atezolizumab, durvalumab, and avelumab ushered a new era in cancer therapy. These inhibitors do not attack tumor cells directly but instead mobilize the immune system to re-recognize and eradicate tumors, which endows them with unique advantages including durable clinical responses and substantial clinical benefits. PD-1/PD-L1 inhibitors, a pillar of immune checkpoint protein inhibitors, have demonstrated unprecedented clinical efficacy in more than 20 cancer types. Besides monoclonal antibodies, diverse PD- 1/PD-L1 inhibiting candidates, such as peptides, small molecules have formed a powerful collection of weapons to fight cancer. The goal of this review is to summarize and discuss the current PD-1/PD-L1 inhibitors including candidates under clinical development, their molecular interactions with PD-1 or PD-L1, the disclosed structureactivity relationships of peptides and small molecules as inhibitors. Current PD-1/PD-L1 inhibitors under clinical development are exclusively dominated by antibodies. The molecular interactions of therapeutic antibodies with PD-1 or PD-L1 have been gradually elucidated for the design of novel inhibitors. Various peptides and traditional small molecules have been investigated in preclinical model to discover novel PD-1/PD-L1 inhibitors. Peptides and small molecules may play an important role in immuno-oncology because they may bind to multiple immune checkpoint proteins via rational design, opening opportunity for a new generation of novel PD-1/PD-L1 inhibitors. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  20. Topological phase, electronic, magnetic and optical properties of ScPdBi compound with Gd, Np and Cm impurities

    Energy Technology Data Exchange (ETDEWEB)

    Narimani, Mitra; Nourbakhsh, Zahra, E-mail: z.nourbakhsh@sci.ui.ac.ir

    2017-07-15

    Highlights: • Gd, Np and Cm impurities induce the magnetic moment in ScPdBi compound. • ScPdBi compound with Gd, Np and Cm impurities has normal band order. • The ε(0) and R(0) increase by increasing the atomic number of X atom. - Abstract: The electronic, magnetic and optical properties of X-doped ScPdBi (X = Gd, Np, Cm) are investigated in the framework of density functional theory. The exchange-correlation potential is treated using generalized gradient approximation with Coulomb interaction parameter. The band order and energy band gap of X-doped ScPdBi are investigated by calculation of band structure. The effect of doping impurity on magnetic properties of ScPdBi compound is studied by calculation of total and partial magnetic moments of X-doped ScPdBi compound. Furthermore, the optical properties of X-doped ScPdBi are calculated and compared in the energy range of 0–25 eV.

  1. Correlation between Mechanical Behavior and Actuator-type Performance of Ni-Ti-Pd High-temperature Shape Memory Alloys

    Science.gov (United States)

    Bigelow, Glen S.; Padula, Santo A., II; Garg, Anita; Noebe, Ronald D.

    2007-01-01

    High-temperature shape memory alloys in the NiTiPd system are being investigated as lower cost alternatives to NiTiPt alloys for use in compact solid-state actuators for the aerospace, automotive, and power generation industries. A range of ternary NiTiPd alloys containing 15 to 46 at.% Pd has been processed and actuator mimicking tests (thermal cycling under load) were used to measure transformation temperatures, work behavior, and dimensional stability. With increasing Pd content, the work output of the material decreased, while the amount of permanent strain resulting from each load-biased thermal cycle increased. Monotonic isothermal tension testing of the high-temperature austenite and low temperature martensite phases was used to partially explain these behaviors, where a mismatch in yield strength between the austenite and martensite phases was observed at high Pd levels. Moreover, to further understand the source of the permanent strain at lower Pd levels, strain recovery tests were conducted to determine the onset of plastic deformation in the martensite phase. Consequently, the work behavior and dimensional stability during thermal cycling under load of the various NiTiPd alloys is discussed in relation to the deformation behavior of the materials as revealed by the strain recovery and monotonic tension tests.

  2. Improved mechanical performance and delayed corrosion phenomena in biodegradable Mg-Zn-Ca alloys through Pd-alloying.

    Science.gov (United States)

    González, S; Pellicer, E; Fornell, J; Blanquer, A; Barrios, L; Ibáñez, E; Solsona, P; Suriñach, S; Baró, M D; Nogués, C; Sort, J

    2012-02-01

    The influence of partial substitution of Mg by Pd on the microstructure, mechanical properties and corrosion behaviour of Mg(72-x)Zn(23)Ca(5)Pd(x) (x=0, 2 and 6 at.%) alloys, synthesized by copper mould casting, is investigated. While the Mg(72)Zn(23)Ca(5) alloy is mainly amorphous, the addition of Pd decreases the glass-forming ability, thus favouring the formation of crystalline phases. From a mechanical viewpoint, the hardness increases with the addition of Pd, from 2.71 GPa for x=0 to 3.9 GPa for x=6, mainly due to the formation of high-strength phases. In turn, the wear resistance is maximized for an intermediate Pd content (i.e., Mg(70)Zn(23)Ca(5)Pd(2)). Corrosion tests in a simulated body fluid (Hank's solution) indicate that Pd causes a shift in the corrosion potential towards more positive values, thus delaying the biodegradability of this alloy. Moreover, since the cytotoxic studies with mouse preosteoblasts do not show dead cells after culturing for 27 h, these alloys are potential candidates to be used as biomaterials. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Time-resolved processes in a pulsed electrical discharge in argon bubbles in water

    Science.gov (United States)

    Gershman, S.; Belkind, A.

    2010-12-01

    A phenomenological picture of a pulsed electrical discharge in gas bubbles in water is produced by combining electrical, spectroscopic, and imaging characterization methods. The discharge is generated by applying 1 μ s pulses of 5 to 20 kV between a needle and a disk electrode submerged in water. An Ar gas bubble surrounds the tip of the needle electrode. Imaging, electrical characteristics, and time-resolved optical emission spectroscopic data suggest a fast streamer propagation mechanism and the formation of a plasma channel in the bubble. Comparing the electrical and imaging data for consecutive pulses applied to the bubble at a frequency of 1 Hz indicates that each discharge proceeds as an entirely new process with no memory of the previous discharge aside from the presence of long-lived chemical species, such as ozone and oxygen. Imaging and electrical data show the presence of two discharge events during each applied voltage pulse, a forward discharge near the beginning of the applied pulse depositing charge on the surface of the bubble and a reverse discharge removing the accumulated charge from the water/gas interface when the applied voltage is turned off. The pd value of ~ 300-500 torr cm, the 1 μs long pulse duration, low repetition rate, and unidirectional character of the applied voltage pulses make the discharge process here unique compared to the traditional corona or dielectric barrier discharges.

  4. MIS gas sensors based on porous silicon with Pd and WO{sub 3}/Pd electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Solntsev, V.S. [Institute of Semiconductor Physics, National Academy of Science of Ukraine, 03028, Kiev (Ukraine); Gorbanyuk, T.I., E-mail: tatyanagor@mail.r [Institute of Semiconductor Physics, National Academy of Science of Ukraine, 03028, Kiev (Ukraine); Litovchenko, V.G.; Evtukh, A.A. [Institute of Semiconductor Physics, National Academy of Science of Ukraine, 03028, Kiev (Ukraine)

    2009-09-30

    Pd and WO{sub 3}/Pd gate metal-oxide-semiconductor (MIS) gas sensitive structures based on porous silicon layers are studied by the high frequency C(V) method. The chemical compositions of composite WO{sub 3}/Pd electrodes are characterized by secondary-ion mass spectrometry (SIMS). The atomic force microscopy (AFM) was used for morphologic studies of WO{sub 3}/Pd films. As shown in the experiments, WO{sub 3}/Pd structures are more sensitive and selective to the adsorption of hydrogen sulphide compared to Pd gate. The analyses of kinetic characteristics allow us to determine the response and characteristic times for these structures. The response time of MIS-structures with thin composite WO{sub 3}/Pd electrodes (the thickness of Pd is about 50 nm with WO{sub 3} clusters on its surface) is slower compared to the structures with Pd electrodes. Slower sensor responses of WO{sub 3}-based gas sensors may be associated with different mechanism of gas sensitivity of given structures. The enhanced sensitivity and selectivity to H{sub 2}S action of WO{sub 3}/Pd MIS-structures can also be explained by the chemical reaction that occurs at the catalytic active surface of gate electrodes. The possible mechanisms of enhanced sensitivity and selectivity to H{sub 2}S adsorption of MIS gas sensors with WO{sub 3}/Pd composite gate electrodes compared to pure Pd have been analyzed.

  5. Investigating unexpected magnetism of mesoporous silica-supported Pd and PdO nanoparticles

    KAUST Repository

    Song, Hyon Min; Zink, Jeffrey I.; Khashab, Niveen M.

    2015-01-01

    supported Pd and PdO NPs. The heating rate and the annealing conditions determine the particle size and the phase of the NPs, with a fast heating rate of 30 °C/min producing the largest supported Pd NPs. Unusual magnetic behaviors are observed. (1) Contrary

  6. Cryogenic high current discharges

    International Nuclear Information System (INIS)

    Meierovich, B.E.

    1994-01-01

    Z-pinches formed from frozen deuterium fibers by a rapidly rising current have enhanced stability and high neutron yield. The efforts to understand the enhanced stability and neutron yield on the basis of classical picture of Bennett equilibrium of the current channel has not given satisfactory results. The traditional approach does not take into account the essential difference between the frozen deuterium fiber Z-pinches and the usual Z-pinches such as exploding wires or classical gas-puffed Z-pinches. The very low temperature of the fiber atoms (10 K), together with the rapidly rising current, result in the coexistence of a high current channel with unionized fiber atoms for a substantial period of time. This phenomena lasts during the risetime. This approach takes into account the difference of the breakdown in a dielectric deuterium fiber and the breakdown in a metallic wire. This difference is essential to the understanding of specific features of cryogenic high current discharges. Z-pinches in frozen deuterium fibers should be considered as a qualitatively new phenomenon on the boundary of cryogenic and high current physics. It is a start of a new branch in plasma physics: the physics of cryogenic high current discharges

  7. Auxiliary partial liver transplantation

    NARCIS (Netherlands)

    C.B. Reuvers (Cornelis Bastiaan)

    1986-01-01

    textabstractIn this thesis studies on auxiliary partial liver transplantation in the dog and the pig are reported. The motive to perform this study was the fact that patients with acute hepatic failure or end-stage chronic liver disease are often considered to form too great a risk for successful

  8. Partial Remission Definition

    DEFF Research Database (Denmark)

    Andersen, Marie Louise Max; Hougaard, Philip; Pörksen, Sven

    2014-01-01

    OBJECTIVE: To validate the partial remission (PR) definition based on insulin dose-adjusted HbA1c (IDAA1c). SUBJECTS AND METHODS: The IDAA1c was developed using data in 251 children from the European Hvidoere cohort. For validation, 129 children from a Danish cohort were followed from the onset...

  9. Fundamental partial compositeness

    DEFF Research Database (Denmark)

    Sannino, Francesco; Strumia, Alessandro; Tesi, Andrea

    2016-01-01

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Unde...

  10. Partially ordered models

    NARCIS (Netherlands)

    Fernandez, R.; Deveaux, V.

    2010-01-01

    We provide a formal definition and study the basic properties of partially ordered chains (POC). These systems were proposed to model textures in image processing and to represent independence relations between random variables in statistics (in the later case they are known as Bayesian networks).

  11. Partially Hidden Markov Models

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Rissanen, Jorma

    1996-01-01

    Partially Hidden Markov Models (PHMM) are introduced. They differ from the ordinary HMM's in that both the transition probabilities of the hidden states and the output probabilities are conditioned on past observations. As an illustration they are applied to black and white image compression where...

  12. Honesty in partial logic

    NARCIS (Netherlands)

    W. van der Hoek (Wiebe); J.O.M. Jaspars; E. Thijsse

    1995-01-01

    textabstractWe propose an epistemic logic in which knowledge is fully introspective and implies truth, although truth need not imply epistemic possibility. The logic is presented in sequential format and is interpreted in a natural class of partial models, called balloon models. We examine the

  13. The effect of partial order on galvanomagnetic transport properties of ferromagnetic PdFe and PdCo alloys

    Czech Academy of Sciences Publication Activity Database

    Kudrnovský, Josef; Drchal, Václav; Turek, Ilja

    2015-01-01

    Roč. 92, č. 22 (2015), "224421-1"-"224421-8" ISSN 1098-0121 R&D Projects: GA ČR GA15-13436S Institutional support: RVO:68378271 ; RVO:68081723 Keywords : anomalous Hall effect * anisotropis magnetoresistance * first-principles * effect of ordering Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.736, year: 2014

  14. DFT study on stability and H{sub 2} adsorption activity of bimetallic Au{sub 79−n}Pd{sub n} (n = 1–55) clusters

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xuejing [State Key Laboratory of Fine Chemicals, Dalian University of Technology, Dalian 116024 (China); Tian, Dongxu, E-mail: tiandx@dlut.edu.cn [State Key Laboratory of Fine Chemicals, Dalian University of Technology, Dalian 116024 (China); Meng, Changgong [State Key Laboratory of Fine Chemicals, Dalian University of Technology, Dalian 116024 (China)

    2013-03-29

    Highlights: ► Stability of Pd substitution type is face > mid-edge > corner > edge. ► H{sub 2} adsorption activity is in contrast with the stability of Pd substitution type. ► Non-activated dissociation of H{sub 2} occurs in Au{sub 36}Pd{sub 43−3} with high thermal stability. ► ε{sub d} agrees with that Pd at edge and corner are more active than face and mid-edge. - Abstract: The stability and H{sub 2} adsorption activity of bimetallic Au{sub 79−n}Pd{sub n} (n = 1–55) clusters were studied by density functional theory with GGA-PW91 functional. The stability order for four Pd substitution types is face > mid-edge > corner > edge, and the stability is improved with increasing Pd content. In contrast with the stability order, H{sub 2} adsorption activity is corner ≈ edge > mid-edge > face. The Au{sub 36}Pd{sub 43} (3) with Au:Pd ≈ 1:1 ratio and twenty-four Pd substitutions at (1 1 1) facets and nineteen Pd substitutions at subshell sites shows high stability and H{sub 2} non-activated dissociation activity. The partial density of d-states and d band center revealed that the electronic properties are closely associated with the geometric characteristic and adsorption activity. Correlating the d band center ε{sub d} and the adsorption energies, the ε{sub d} order agrees with the adsorption activity that the Pd substitution at edge and corner sites are more active than at face and mid-edge sites.

  15. Algebraic partial Boolean algebras

    International Nuclear Information System (INIS)

    Smith, Derek

    2003-01-01

    Partial Boolean algebras, first studied by Kochen and Specker in the 1960s, provide the structure for Bell-Kochen-Specker theorems which deny the existence of non-contextual hidden variable theories. In this paper, we study partial Boolean algebras which are 'algebraic' in the sense that their elements have coordinates in an algebraic number field. Several of these algebras have been discussed recently in a debate on the validity of Bell-Kochen-Specker theorems in the context of finite precision measurements. The main result of this paper is that every algebraic finitely-generated partial Boolean algebra B(T) is finite when the underlying space H is three-dimensional, answering a question of Kochen and showing that Conway and Kochen's infinite algebraic partial Boolean algebra has minimum dimension. This result contrasts the existence of an infinite (non-algebraic) B(T) generated by eight elements in an abstract orthomodular lattice of height 3. We then initiate a study of higher-dimensional algebraic partial Boolean algebras. First, we describe a restriction on the determinants of the elements of B(T) that are generated by a given set T. We then show that when the generating set T consists of the rays spanning the minimal vectors in a real irreducible root lattice, B(T) is infinite just if that root lattice has an A 5 sublattice. Finally, we characterize the rays of B(T) when T consists of the rays spanning the minimal vectors of the root lattice E 8

  16. Structural Biology of the Immune Checkpoint Receptor PD-1 and Its Ligands PD-L1/PD-L2

    NARCIS (Netherlands)

    Zak, Krzysztof M.; Grudnik, Przemyslaw; Magiera, Katarzyna; Dömling, Alexander; Dubin, Grzegorz; Holak, Tad A.

    2017-01-01

    Cancer cells can avoid and suppress immune responses through activation of inhibitory immune checkpoint proteins, such as PD-1, PD-L1, and CTLA-4. Blocking the activities of these proteins with monoclonal antibodies, and thus restoring T cell function, has delivered breakthrough therapies against

  17. Self-stabilized discharge filament in plane-parallel barrier discharge configuration: formation, breakdown mechanism, and memory effects

    Science.gov (United States)

    Tschiersch, R.; Nemschokmichal, S.; Bogaczyk, M.; Meichsner, J.

    2017-10-01

    Single self-stabilized discharge filaments were investigated in the plane-parallel electrode configuration. The barrier discharge was operated inside a gap of 3 mm shielded by glass plates to both electrodes, using helium-nitrogen mixtures and a square-wave feeding voltage at a frequency of 2 kHz. The combined application of electrical measurements, ICCD camera imaging, optical emission spectroscopy and surface charge diagnostics via the electro-optic Pockels effect allowed the correlation of the discharge development in the volume and on the dielectric surfaces. The formation criteria and existence regimes were found by systematic variation of the nitrogen admixture to helium, the total pressure and the feeding voltage amplitude. Single self-stabilized discharge filaments can be operated over a wide parameter range, foremost, by significant reduction of the voltage amplitude after the operation in the microdischarge regime. Here, the outstanding importance of the surface charge memory effect on the long-term stability was pointed out by the recalculated spatio-temporally resolved gap voltage. The optical emission revealed discharge characteristics that are partially reminiscent of both the glow-like barrier discharge and the microdischarge regime, such as a Townsend pre-phase, a fast cathode-directed ionization front during the breakdown and radially propagating surface discharges during the afterglow.

  18. Diffusion of condenser water discharge

    International Nuclear Information System (INIS)

    Iwakiri, Toshio

    1977-01-01

    Thermal and nuclear power stations in Japan are mostly located in coastal area, and the cooling water is discharged into sea as warm water. Recently, large interest is taken in this matter, and it is desirable to predict the diffusion of warm discharge accurately and to take effective measures for lowering the temperature. As for the methods of predicting the diffusion of warm discharge, simplified estimation, mathematical analysis and hydrographical model experiment are used corresponding to objects and conditions. As for the measures to lower temperature, the method of discharging warm water into deep sea bottom was confirmed to be very effective. In this paper, the phenomena of diffusion of warm discharge in sea, the methods of predicting the diffusion of warm discharge, and the deep sea discharge as the measure for lowering temperature are outlined. The factors concerning the diffusion of warm discharge in sea are the conditions of discharge, topography and sea state, and the diffusion is roughly divided into mixing diffusion in the vicinity of warm water outlet and eddy diffusion in distant region. It is difficult to change artificially the conditions of diffusion in distant region, and the measures of raising the rate of dilution in near region are effective, therefore the deep sea discharge is adopted. (Kako, I.)

  19. Heart bypass surgery - minimally invasive - discharge

    Science.gov (United States)

    ... invasive direct coronary artery bypass - discharge; MIDCAB - discharge; Robot assisted coronary artery bypass - discharge; RACAB - discharge; Keyhole ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  20. Vaginal Discharge: What's Normal, What's Not

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Vaginal Discharge: What's Normal, What's Not KidsHealth / For Teens / ... Discharge: What's Normal, What's Not Print What Is Vaginal Discharge? Vaginal discharge is fluid that comes from ...

  1. In-situ study of hydriding kinetics in Pd-based thin film systems

    Energy Technology Data Exchange (ETDEWEB)

    Delmelle, Renaud; Proost, Joris [Univ. Catholique de Louvain, Louvain-la-Neuve (Belgium). Div. of Materials and Process Engineering

    2010-07-01

    The hydriding kinetics of Pd thin films has been investigated in detail. The key experimental technique used in this work consists of a high resolution curvature measurement setup, which continuously monitors the reflections of multiple laser beams coming off a cantilevered sample. After mounting the sample inside a vacuum chamber, a H-containing gas mixture is introduced to instantaneously generate a given hydrogen partial pressure (p{sub H2}) inside the chamber. The resulting interaction of H with the Pd layer then leads to a volume expansion of the thin film system. This induces in turn changes in the sample curvature as a result of internal stresses developing in the Pd film during a hydriding cycle. Based on such curvature date obtained in-situ at different p{sub H2}, a two-step model for the kinetics of Pd-hydride formation has been proposed and expressions for the hydrogen adsorption and absorption velocities have been derived. The rate-limiting steps have been identified by studying the p{sub H2}-dependence of these velocities. Furthermore, from our in-situ experimental data, relevant kinetic parameters have been calculated. The effect of dry air exposure of the Pd films on the hydriding kinetics has been considered as well. (orig.)

  2. Analysis of Multipactor Discharge

    International Nuclear Information System (INIS)

    Lau, Y. Y.

    2005-01-01

    Several comprehensive studies of radio frequency (rf) breakdown and rf heating are reported. They are of general interest to magnetic confinement fusion, rf linac, and high power microwave source development. The major results include: (1) a ground-breaking theory of multipactor discharge on dielectric, including a successful proof-of-principle experiment that verified the newly developed scaling laws, (2) an in depth investigation of the failure mechanisms of diamond windows and ceramic windows, and of the roles of graphitization, thin films of coating and contaminants, and (3) a most comprehensive theory, to date, on the heating of particulates by an electromagnetic pulse, and on the roles of rf magnetic field heating and of rf electric field heating, including the construction of new scaling laws that govern them. The above form a valuable knowledge base for the general problem of heating phenomenology

  3. Radioactive wastes and discharges

    International Nuclear Information System (INIS)

    1993-01-01

    According to the Section 24 of the Finnish Radiation Decree (1512/91), the Finnish Centre for Radiation and Nuclear Safety shall specify the concentration and activity limits and principles for the determination whether a waste can be defined as a radioactive waste or not. The radiation safety requirements and limits for the disposal of radioactive waste are given in the guide. They must be observed when discharging radioactive waste into the atmosphere or sewer system, or when delivering solid low-activity waste to a landfill site without a separate waste disposal plan. The guide does not apply to the radioactive waste resulting from the utilization of nuclear energy of natural resources. (4 refs., 1 tab.)

  4. One-pot synthesis of Pd-Pt@Pd core-shell nanocrystals with enhanced electrocatalytic activity for formic acid oxidation

    KAUST Repository

    Yuan, Qiang; Huang, Dabing; Wang, Honghui; Zhou, Zhiyou; Wang, Qingxiao

    2014-01-01

    Well-defined Pd-Pt@Pd core-shell nanocrystals with a Pd-Pt alloy core and a conformal Pd shell of ~2-3 nm were directly synthesized through a one-pot, aqueous solution approach without any preformed Pd or Pt seeds. These Pd-Pt@Pd core

  5. Two apparent glucose-6-phosphate dehydrogenase variants in normal XY males: G6PD Alabama.

    Science.gov (United States)

    Prchal, J T; Hall, K; Csepreghy, M; Lilly, M; Berkow, R; Scott, C W

    1988-03-01

    A six-year-old black boy who had transient hemolysis after a viral infection was found to have mildly decreased red cell glucose-6-phosphate dehydrogenase (G6PD) activity (1.25 IU/g hemoglobin). Two G6PD bands, both slightly faster than normal G6PD B, were seen on electrophoresis in both the propositus as well as in his maternal grandfather. This is an unexpected finding, since the G6PD gene is located on the long arm of the X chromosome that is subject to X-chromosome inactivation, and available evidence indicates that it is present as a single functional copy in the human genome. The obvious possibility of duplication of the X chromosome was eliminated by cytogenetic analysis with G-banding. G6PD duplication is unlikely, since peripheral blood granulocytes, platelets, and lymphocytes; cultured skin and bone marrow fibroblasts; and Epstein-Barr virus-stimulated lymphocytes yielded only a single electrophoretic band with mobility identical to the slower band seen in crude red blood cell hemolysate. Study of partially purified red blood cell hemolysate G6PD also yielded a single band with identical mobility. Kinetic studies of the enzyme in the propositus and in three generations of his family identified a unique, previously unpublished G6PD mutant that is herein designated G6PD Alabama. Red blood cells were separated by density gradient into a reticulocyte-enriched, an intermediate, and a dense, older portion. Two distinct enzyme bands were identified on electrophoresis of hemolysate from the reticulocyte-enriched portion, but not from the other two portions. It is postulated that two transcriptional products of the mutant G6PD gene exist; one with a short half-life and detectable only in young red blood cells, and another with a longer half-life present in all cells. The existence of two distinct mutant genes in the genome or a unique post-translational form of the mutant G6PD detected only in reticulocytes cannot be excluded.

  6. The characteristics of SPECT images in childhood benign partial epilepsy

    International Nuclear Information System (INIS)

    Jia Shaowei; Liao Jianxiang; Liu Xiaoyan; Zheng Xiyuan; Qin Jiong; Pan Zhongyun; Zuo Qihua

    1998-01-01

    Purpose: To investigate childhood benign partial epilepsy (BPE) with SPECT. Methods: Double SPECT imaging was performed on 21 cases of BPE at the stage of wake (interval spike discharge) and sleep (spike discharge), under EEG monitoring. The transverse images were reconstructed after digital image subtraction. The quantitative analysis was conducted with brain flow change rate (BFCR) % mathematical model. Results: EEG monitoring demonstrated approximately normal background of 21 cases of BPE during the stage of wake, and spike discharge frequency markedly increased during the stage of sleep, 117 foci were showed by SPeCT in cases of BPE, and the average was 5.6 +- 1.6 foci/case. The characteristics of SPECT transverse images were 1) multiple foci of mirror, 2) mostly seen in Rolandic region, 3) circular symbol, 4) the radioactivity in foci decreased during the stage of wake (interval spike discharge) and increased during the stage of sleep (spike discharge). The concordance of SPECT and EEG was 93.1% (109/117 foci). The BFCR% of all epileptogenic foci exceeded normal limit (99% confidence interval). There was no correlation between the spike discharge frequency and BFCR% (r = 0.45, P>0.05). Conclusions: Regional cerebral blood flow and function were abnormal during the epileptogenic foci were discharging abnormally in BPE

  7. (G6PD) in stored blood

    African Journals Online (AJOL)

    Red blood cell viability in stored blood determines successful transfusion. Glucose-6-phosphate dehydrogenase (G6PD) activity has been shown to maintain red blood cell membrane integrity. This study was, therefore, aimed at estimating the G6PD activity in stored blood bags at the blood bank of the University of Nigeria ...

  8. H-H interactions in Pd

    DEFF Research Database (Denmark)

    Christensen, O. B.; Ditlevsen, Peter; Jacobsen, Karsten Wedel

    1989-01-01

    -medium theory to calculate total energies we show the same tendency for the short-range part of the H-H interaction when two H atoms are squeezed into a single site in Pd or PdH. At longer range (of the order a lattice constant) there is an attractive, lattice-mediated H-H interaction. On the basis...

  9. Partially composite Higgs models

    DEFF Research Database (Denmark)

    Alanne, Tommi; Buarque Franzosi, Diogo; Frandsen, Mads T.

    2018-01-01

    We study the phenomenology of partially composite-Higgs models where electroweak symmetry breaking is dynamically induced, and the Higgs is a mixture of a composite and an elementary state. The models considered have explicit realizations in terms of gauge-Yukawa theories with new strongly...... interacting fermions coupled to elementary scalars and allow for a very SM-like Higgs state. We study constraints on their parameter spaces from vacuum stability and perturbativity as well as from LHC results and find that requiring vacuum stability up to the compositeness scale already imposes relevant...... constraints. A small part of parameter space around the classically conformal limit is stable up to the Planck scale. This is however already strongly disfavored by LHC results. in different limits, the models realize both (partially) composite-Higgs and (bosonic) technicolor models and a dynamical extension...

  10. Arthroscopic partial medial meniscectomy

    Directory of Open Access Journals (Sweden)

    Dašić Žarko

    2011-01-01

    Full Text Available Background/Aim. Meniscal injuries are common in professional or recreational sports as well as in daily activities. If meniscal lesions lead to physical impairment they usually require surgical treatment. Arthroscopic treatment of meniscal injuries is one of the most often performed orthopedic operative procedures. Methods. The study analyzed the results of arthroscopic partial medial meniscectomy in 213 patients in a 24-month period, from 2006, to 2008. Results. In our series of arthroscopically treated medial meniscus tears we noted 78 (36.62% vertical complete bucket handle lesions, 19 (8.92% vertical incomplete lesions, 18 (8.45% longitudinal tears, 35 (16.43% oblique tears, 18 (8.45% complex degenerative lesions, 17 (7.98% radial lesions and 28 (13.14% horisontal lesions. Mean preoperative International Knee Documentation Committee (IKDC score was 49.81%, 1 month after the arthroscopic partial medial meniscectomy the mean IKDC score was 84.08%, and 6 months after mean IKDC score was 90.36%. Six months after the procedure 197 (92.49% of patients had good or excellent subjective postoperative clinical outcomes, while 14 (6.57% patients subjectively did not notice a significant improvement after the intervention, and 2 (0.93% patients had no subjective improvement after the partial medial meniscectomy at all. Conclusion. Arthroscopic partial medial meniscetomy is minimally invasive diagnostic and therapeutic procedure and in well selected cases is a method of choice for treatment of medial meniscus injuries when repair techniques are not a viable option. It has small rate of complications, low morbidity and fast rehabilitation.

  11. Dicarboxylic acids from electric discharge

    Science.gov (United States)

    Zeitman, B.; Chang, S.; Lawless, J. G.

    1974-01-01

    An investigation was conducted concerning the possible synthesis of a suite of dicarboxylic acids similar to that found in the Murchison meteorite. The investigation included the conduction of a chemical evolution experiment which simulated electric discharge through the primitive atmosphere of the earth. The suite of dicarboxylic acids obtained in the electric discharge experiment is similar to that of the Murchison meteorite, except for the fact that 2-chlorosuccinic acid is present in the spark discharge.

  12. Hierarchical partial order ranking

    International Nuclear Information System (INIS)

    Carlsen, Lars

    2008-01-01

    Assessing the potential impact on environmental and human health from the production and use of chemicals or from polluted sites involves a multi-criteria evaluation scheme. A priori several parameters are to address, e.g., production tonnage, specific release scenarios, geographical and site-specific factors in addition to various substance dependent parameters. Further socio-economic factors may be taken into consideration. The number of parameters to be included may well appear to be prohibitive for developing a sensible model. The study introduces hierarchical partial order ranking (HPOR) that remedies this problem. By HPOR the original parameters are initially grouped based on their mutual connection and a set of meta-descriptors is derived representing the ranking corresponding to the single groups of descriptors, respectively. A second partial order ranking is carried out based on the meta-descriptors, the final ranking being disclosed though average ranks. An illustrative example on the prioritisation of polluted sites is given. - Hierarchical partial order ranking of polluted sites has been developed for prioritization based on a large number of parameters

  13. Multiplexed Immunofluorescence Reveals Potential PD-1/PD-L1 Pathway Vulnerabilities in Craniopharyngioma.

    Science.gov (United States)

    Coy, Shannon; Rashid, Rumana; Lin, Jia-Ren; Du, Ziming; Donson, Andrew M; Hankinson, Todd C; Foreman, Nicholas K; Manley, Peter E; Kieran, Mark W; Reardon, David A; Sorger, Peter K; Santagata, Sandro

    2018-03-02

    Craniopharyngiomas are neoplasms of the sellar/parasellar region that are classified into adamantinomatous (ACP) and papillary (PCP) subtypes. Surgical resection of craniopharyngiomas is challenging, and recurrence is common, frequently leading to profound morbidity. BRAF V600E mutations render PCP susceptible to BRAF/MEK inhibitors, but effective targeted therapies are needed for ACP. We explored the feasibility of targeting the PD-1/PD-L1 immune checkpoint pathway in ACP and PCP. We mapped and quantified PD-L1 and PD-1 expression in ACP and PCP resections using immunohistochemistry, immunofluorescence, and RNA in situ hybridization. We used tissue-based cyclic immunofluorescence (t-CyCIF) to map the spatial distribution of immune cells and characterize cell cycle and signaling pathways in ACP tumor cells which intrinsically express PD-1. All ACP (15±14% of cells, n=23, average±S.D.) and PCP (35±22% of cells, n=18) resections expressed PD-L1. In ACP, PD-L1 was predominantly expressed by tumor cells comprising the cyst-lining. In PCP, PD-L1 was highly-expressed by tumor cells surrounding the stromal fibrovascular cores. ACP also exhibited tumor cell-intrinsic PD-1 expression in whorled epithelial cells with nuclear-localized beta-catenin. These cells exhibited evidence of elevated mTOR and MAPK signaling. Profiling of immune populations in ACP and PCP showed a modest density of CD8+ T-cells. ACP exhibit PD-L1 expression in the tumor cyst-lining and intrinsic PD-1 expression in cells proposed to comprise an oncogenic stem-like population. In PCP, proliferative tumor cells express PD-L1 in a continuous band at the stromal-epithelial interface. Targeting PD-L1 and/or PD-1 in both subtypes of craniopharyngioma might therefore be an effective therapeutic strategy.

  14. Ultrahigh vacuum dc magnetron sputter-deposition of epitaxial Pd(111)/Al2O3(0001) thin films.

    Science.gov (United States)

    Aleman, Angel; Li, Chao; Zaid, Hicham; Kindlund, Hanna; Fankhauser, Joshua; Prikhodko, Sergey V; Goorsky, Mark S; Kodambaka, Suneel

    2018-05-01

    Pd(111) thin films, ∼245 nm thick, are deposited on Al 2 O 3 (0001) substrates at ≈0.5 T m , where T m is the Pd melting point, by ultrahigh vacuum dc magnetron sputtering of Pd target in pure Ar discharges. Auger electron spectra and low-energy electron diffraction patterns acquired in situ from the as-deposited samples reveal that the surfaces are compositionally pure 111-oriented Pd. Double-axis x-ray diffraction (XRD) ω-2θ scans show only the set of Pd 111 peaks from the film. In triple-axis high-resolution XRD, the full width at half maximum intensity Γ ω of the Pd 111 ω-rocking curve is 630 arc sec. XRD 111 pole figure obtained from the sample revealed six peaks 60°-apart at a tilt angles corresponding to Pd 111 reflections. XRD ϕ scans show six 60°-rotated 111 peaks of Pd at the same ϕ angles for 11[Formula: see text]3 of Al 2 O 3 based on which the epitaxial crystallographic relationships between the film and the substrate are determined as [Formula: see text]ǁ[Formula: see text] with two in-plane orientations of [Formula: see text]ǁ[Formula: see text] and [Formula: see text]ǁ[Formula: see text]. Using triple axis symmetric and asymmetric reciprocal space maps, interplanar spacings of out-of-plane (111) and in-plane (11[Formula: see text]) are found to be 0.2242 ± 0.0003 and 0.1591 ± 0.0003 nm, respectively. These values are 0.18% lower than 0.2246 nm for (111) and the same, within the measurement uncertainties, as 0.1588 nm for (11[Formula: see text]) calculated from the bulk Pd lattice parameter, suggesting a small out-of-plane compressive strain and an in-plane tensile strain related to the thermal strain upon cooling the sample from the deposition temperature to room temperature. High-resolution cross-sectional transmission electron microscopy coupled with energy dispersive x-ray spectra obtained from the Pd(111)/Al 2 O 3 (0001) samples indicate that the Pd-Al 2 O 3 interfaces are essentially atomically abrupt and

  15. Electron Bernstein wave current drive in the start-up phase of a tokamak discharge

    International Nuclear Information System (INIS)

    Montes, A.; Ludwig, G.O.

    1986-04-01

    Current drive by electron Bernstein waves in the start-up phase of tokamak discharges is studied. A general analytical expression is derived for the figure of merit J/Pd associated with these waves. This is coupled with a ray tracing code, allowing the calculation of the total current generated per unit of incident power in realistic tokamak conditions. The resuts show that the electron Bernstein waves can drive substantial currents even at very low electron temperatures. (Author) [pt

  16. Partial synchronization of different chaotic oscillators using robust PID feedback

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar-Lopez, Ricardo [Departamento de Energia, Universidad Autonoma Metropolitana - Azcapotzalco, San Pablo 180, Reynosa-Tamaulipas, Azcapotzalco, 02200 Mexico, D.F. (Mexico)]. E-mail: raguilar@correo.azc.uam.mx; Martinez-Guerra, Rafael [Departamento de Control Automatico, CINVESTAV IPN, Apartado Postal 14-740, Mexico, D.F. C.P. 07360 (Mexico)]. E-mail: rguerra@ctrl.cinvestav.mx

    2007-07-15

    This work deals with the partial synchronization problem of two different chaotic oscillators considering model uncertainties in the slave system via control approach. The slave system is forced to follow the master signal via a linearizing controller based on model uncertainty reconstructor which leads to proportional-integral-derivative (PID) control structure. This reconstructor is related with a proportional-derivative (PD) reduced-order observer, it would be considered as a sub-slave system for the original slave of the synchronization procedure. The asymptotic performance of the synchronization methodology is proven via the dynamic of the synchronization error. Numerical experiment illustrates the closed-loop behavior of the proposed methodology.

  17. Partial synchronization of different chaotic oscillators using robust PID feedback

    International Nuclear Information System (INIS)

    Aguilar-Lopez, Ricardo; Martinez-Guerra, Rafael

    2007-01-01

    This work deals with the partial synchronization problem of two different chaotic oscillators considering model uncertainties in the slave system via control approach. The slave system is forced to follow the master signal via a linearizing controller based on model uncertainty reconstructor which leads to proportional-integral-derivative (PID) control structure. This reconstructor is related with a proportional-derivative (PD) reduced-order observer, it would be considered as a sub-slave system for the original slave of the synchronization procedure. The asymptotic performance of the synchronization methodology is proven via the dynamic of the synchronization error. Numerical experiment illustrates the closed-loop behavior of the proposed methodology

  18. Anti-tumor immunotherapy by blockade of the PD-1/PD-L1 pathway with recombinant human PD-1-IgV.

    Science.gov (United States)

    Zhang, C; Wu, S; Xue, X; Li, M; Qin, X; Li, W; Han, W; Zhang, Y

    2008-01-01

    Blockade of the programmed death-1 (PD-1)/PD-ligand 1 (PD-L1) pathway can delay tumor growth and prolong the survival of tumor-bearing mice. The extracellular immunoglobulin (Ig) V domain of PD-1 is important for the interaction between PD-1 and PD-L1, suggesting that PD-1-IgV may be a potential target for anti-tumor immunotherapy. The extracellular sequence of human PD-1-IgV (hPD-1-IgV) was expressed in Escherichia coli and purified. The anti-tumor effect of hPD-1-IgV on tumor-bearing mice was tested. hPD-1-IgV recombinant protein could bind PD-L1 at molecular and cellular levels and enhance Cytotoxic T Lymphocyte (CTL) activity and anti-tumor effect on tumor-bearing mice in vivo. The percentage of CD4(+)CD25(+) T cells in tumor-bearing mice was decreased compared with control mice after administration of the recombinant protein. Our results suggest that inhibition of the interaction between PD-1 and PD-L1 by hPD-1-IgV may be a promising strategy for specific tumor immunotherapy.

  19. An aqueous rechargeable formate-based hydrogen battery driven by heterogeneous Pd catalysis.

    Science.gov (United States)

    Bi, Qing-Yuan; Lin, Jian-Dong; Liu, Yong-Mei; Du, Xian-Long; Wang, Jian-Qiang; He, He-Yong; Cao, Yong

    2014-12-01

    The formate-based rechargeable hydrogen battery (RHB) promises high reversible capacity to meet the need for safe, reliable, and sustainable H2 storage used in fuel cell applications. Described herein is an additive-free RHB which is based on repetitive cycles operated between aqueous formate dehydrogenation (discharging) and bicarbonate hydrogenation (charging). Key to this truly efficient and durable H2 handling system is the use of highly strained Pd nanoparticles anchored on graphite oxide nanosheets as a robust and efficient solid catalyst, which can facilitate both the discharging and charging processes in a reversible and highly facile manner. Up to six repeated discharging/charging cycles can be performed without noticeable degradation in the storage capacity. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Investigating unexpected magnetism of mesoporous silica-supported Pd and PdO nanoparticles

    KAUST Repository

    Song, Hyon Min

    2015-01-13

    The synthesis and magnetic behavior of matrix-supported Pd and PdO nanoparticles (NPs) are described. Mesoporous silica with hexagonal columnal packing is selected as a template, and the impregnation method with thermal annealing is used to obtain supported Pd and PdO NPs. The heating rate and the annealing conditions determine the particle size and the phase of the NPs, with a fast heating rate of 30 °C/min producing the largest supported Pd NPs. Unusual magnetic behaviors are observed. (1) Contrary to the general belief that smaller Pd NPs or cluster size particles have higher magnetization, matrix-supported Pd NPs in this study maintain the highest magnetization with room temperature ferromagnetism when the size is the largest. (2) Twin boundaries along with stacking faults are more pronounced in these large Pd NPs and are believed to be the reason for this high magnetization. Similarly, supported PdO NPs were prepared under air conditions with different heating rates. Their phase is tetragonal (P42/mmc) with cell parameters of a = 3.050 Å and c = 5.344 Å, which are slightly larger than in the bulk phase (a = 3.03 Å, c = 5.33 Å). Faster heating rate of 30 °C/min also produces larger particles and larger magnetic hysteresis loop, although magnetization is smaller and few twin boundaries are observed compared to the supported metallic Pd NPs.

  1. Partially ordered algebraic systems

    CERN Document Server

    Fuchs, Laszlo

    2011-01-01

    Originally published in an important series of books on pure and applied mathematics, this monograph by a distinguished mathematician explores a high-level area in algebra. It constitutes the first systematic summary of research concerning partially ordered groups, semigroups, rings, and fields. The self-contained treatment features numerous problems, complete proofs, a detailed bibliography, and indexes. It presumes some knowledge of abstract algebra, providing necessary background and references where appropriate. This inexpensive edition of a hard-to-find systematic survey will fill a gap i

  2. Infinite partial summations

    International Nuclear Information System (INIS)

    Sprung, D.W.L.

    1975-01-01

    This paper is a brief review of those aspects of the effective interaction problem that can be grouped under the heading of infinite partial summations of the perturbation series. After a brief mention of the classic examples of infinite summations, the author turns to the effective interaction problem for two extra core particles. Their direct interaction is summed to produce the G matrix, while their indirect interaction through the core is summed in a variety of ways under the heading of core polarization. (orig./WL) [de

  3. On universal partial words

    OpenAIRE

    Chen, Herman Z. Q.; Kitaev, Sergey; Mütze, Torsten; Sun, Brian Y.

    2016-01-01

    A universal word for a finite alphabet $A$ and some integer $n\\geq 1$ is a word over $A$ such that every word in $A^n$ appears exactly once as a subword (cyclically or linearly). It is well-known and easy to prove that universal words exist for any $A$ and $n$. In this work we initiate the systematic study of universal partial words. These are words that in addition to the letters from $A$ may contain an arbitrary number of occurrences of a special `joker' symbol $\\Diamond\

  4. Partial differential equations

    CERN Document Server

    Agranovich, M S

    2002-01-01

    Mark Vishik's Partial Differential Equations seminar held at Moscow State University was one of the world's leading seminars in PDEs for over 40 years. This book celebrates Vishik's eightieth birthday. It comprises new results and survey papers written by many renowned specialists who actively participated over the years in Vishik's seminars. Contributions include original developments and methods in PDEs and related fields, such as mathematical physics, tomography, and symplectic geometry. Papers discuss linear and nonlinear equations, particularly linear elliptic problems in angles and gener

  5. Partial differential equations

    CERN Document Server

    Levine, Harold

    1997-01-01

    The subject matter, partial differential equations (PDEs), has a long history (dating from the 18th century) and an active contemporary phase. An early phase (with a separate focus on taut string vibrations and heat flow through solid bodies) stimulated developments of great importance for mathematical analysis, such as a wider concept of functions and integration and the existence of trigonometric or Fourier series representations. The direct relevance of PDEs to all manner of mathematical, physical and technical problems continues. This book presents a reasonably broad introductory account of the subject, with due regard for analytical detail, applications and historical matters.

  6. Partial differential equations

    CERN Document Server

    Sloan, D; Süli, E

    2001-01-01

    /homepage/sac/cam/na2000/index.html7-Volume Set now available at special set price ! Over the second half of the 20th century the subject area loosely referred to as numerical analysis of partial differential equations (PDEs) has undergone unprecedented development. At its practical end, the vigorous growth and steady diversification of the field were stimulated by the demand for accurate and reliable tools for computational modelling in physical sciences and engineering, and by the rapid development of computer hardware and architecture. At the more theoretical end, the analytical insight in

  7. Elliptic partial differential equations

    CERN Document Server

    Han, Qing

    2011-01-01

    Elliptic Partial Differential Equations by Qing Han and FangHua Lin is one of the best textbooks I know. It is the perfect introduction to PDE. In 150 pages or so it covers an amazing amount of wonderful and extraordinary useful material. I have used it as a textbook at both graduate and undergraduate levels which is possible since it only requires very little background material yet it covers an enormous amount of material. In my opinion it is a must read for all interested in analysis and geometry, and for all of my own PhD students it is indeed just that. I cannot say enough good things abo

  8. Generalized Partial Volume

    DEFF Research Database (Denmark)

    Darkner, Sune; Sporring, Jon

    2011-01-01

    Mutual Information (MI) and normalized mutual information (NMI) are popular choices as similarity measure for multimodal image registration. Presently, one of two approaches is often used for estimating these measures: The Parzen Window (PW) and the Generalized Partial Volume (GPV). Their theoret...... of view as well as w.r.t. computational complexity. Finally, we present algorithms for both approaches for NMI which is comparable in speed to Sum of Squared Differences (SSD), and we illustrate the differences between PW and GPV on a number of registration examples....

  9. Discharge cleaning for a tokamak

    International Nuclear Information System (INIS)

    Ishii, Shigeyuki

    1983-01-01

    Various methods of discharge cleaning for tokamaks are described. The material of the first walls of tokamaks is usually stainless steel, inconel, titanium and so on. Hydrogen is exclusively used as the discharge gas. Glow discharge cleaning (GDC), Taylor discharge cleaning (TDC), and electron cyclotron resonance discharge cleaning (ECR-DC) are discussed in this paper. The cleaning by GDC is made by moving a movable anode to the center of a tokamak vassel. Taylor found the good cleaning effect of induced discharge by high pressure and low power discharge. This is called TDC. When the frequency of high frequency discharge in a magnetic field is equal to that of the electron cyclotron resonance, the break down potential is lowered if the pressure is sufficiently low. The ECR-CD is made by using this effect. In TDC and ECR-DC, the electron temperature, which has a close relation to the production rate of H 0 , can be controlled by the pressure. In GDC, the operating pressure was improved by the radio frequency glow (RG) method. However, there is still the danger of arcing. In case of GDC and ECR-DC, the position of plasma can be controlled, but not in case of TDC. The TDC is accepted by most of takamak devices in the world. (Kato, T.)

  10. Electrochemical hydrogen storage in ZrCrNiPd{sub x} alloys

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, F.C. [Centro Atomico Bariloche (CAB), Comision Nacional de Energia Atomica (CNEA), C. P. 8400, S. C. de Bariloche (RN) (Argentina); CONICET Consejo Nacional de Investigaciones Cientificas y Tecnicas, Av. Rivadavia 1917, C1033AAJ, Ciudad de Buenos Aires (Argentina); Peretti, H.A. [Centro Atomico Bariloche (CAB), Comision Nacional de Energia Atomica (CNEA), C. P. 8400, S. C. de Bariloche (RN) (Argentina); Instituto Balseiro, Universidad Nacional de Cuyo, C. P. 8400, S. C. de Bariloche (RN) (Argentina); Visintin, A. [CONICET Consejo Nacional de Investigaciones Cientificas y Tecnicas, Av. Rivadavia 1917, C1033AAJ, Ciudad de Buenos Aires (Argentina); Instituto de Investigaciones Fisicoquimicas, Teoricas y Aplicadas, Universidad Nacional de La Plata, Suc. 4, C.C.: 16/Comision de Investigaciones Cientificas Provincia de Buenos Aires (C.I.C.), CP: 1900, La Plata (Argentina)

    2010-06-15

    The consumption of rechargeable batteries at worldwide level has increased constantly in the last years, mainly due to the use of portable devices such as cellular phones, digital cameras, computers, music and video reproducers, etc. Nickel Metal Hydride (NiMH) is a rechargeable battery system widely used in these devices, also including the most of electrical and hybrid vehicles (EV and HEV). The study of hydride forming alloys is fundamental for its use as negative electrode component in NiMH batteries. In previous works, the electrocatalytic effect of Pd element addition to the electrode, in powder form and by means of electroless technique, has been studied. In this work, AB{sub 2}-type alloys are studied, in which Pd is incorporated to the structure by re-melting inside an arc furnace. The base alloy composition is ZrCrNi, and the composition of the elaborated compounds is ZrCrNiPd{sub x} (x = 0.095 and 0.19). The effect of the composition modification on these materials on properties such as electrochemical discharge capacity, activation and high rate dischargeability (HRD) is analyzed. (author)

  11. The practice of terminal discharge.

    Science.gov (United States)

    Radha Krishna, Lalit Kumar; Murugam, Vengadasalam; Quah, Daniel Song Chiek

    2017-01-01

    'Terminal discharges' are carried out in Singapore for patients who wish to die at home. However, if due diligence is not exercised, parallels may be drawn with euthanasia. We present a theoretical discussion beginning with the definition of terminal discharges and the reasons why they are carried out in Singapore. By considering the intention behind terminal discharges and utilising a multidisciplinary team to deliberate on the clinical, social and ethical intricacies with a patient- and context-specific approach, euthanasia is avoided. It is hoped that this will provide a platform for professionals in palliative medicine to negotiate challenging issues when arranging a terminal discharge, so as to avoid the pitfall of committing euthanasia in a country such as Singapore where euthanasia is illegal. It is hoped that a set of guidelines for terminal discharges may someday be realised to assist professionals in Singapore and around the world.

  12. The ASDEX Upgrade discharge schedule

    International Nuclear Information System (INIS)

    Neu, G.; Engelhardt, K.; Raupp, G.; Treutterer, W.; Zasche, D.; Zehetbauer, T.

    2007-01-01

    ASDEX Upgrade's recently commissioned discharge control system (DCS) marks the transition from a traditional programmed system to a highly flexible 'data driven' one. The allocation of application processes (APs) to controllers, the interconnection of APs through uniquely named signals, and AP control parameter values are all defined as data, and can easily be adapted to the requirements of a particular discharge. The data is laid down in a set of XML documents which APs request via HTTP from a configuration server before a discharge. The use of XML allows for easy parsing, and structural validation through (XSD) schemas. The central input to the configuration process is the discharge schedule (DS), which embodies the dynamic behaviour of a planned discharge as reference trajectories grouped in segments, concatenated through transition conditions. Editing, generation and validation tools, and version control through CVS allow for efficient management of DSs

  13. Unilateral removable partial dentures.

    Science.gov (United States)

    Goodall, W A; Greer, A C; Martin, N

    2017-01-27

    Removable partial dentures (RPDs) are widely used to replace missing teeth in order to restore both function and aesthetics for the partially dentate patient. Conventional RPD design is frequently bilateral and consists of a major connector that bridges both sides of the arch. Some patients cannot and will not tolerate such an extensive appliance. For these patients, bridgework may not be a predictable option and it is not always possible to provide implant-retained restorations. This article presents unilateral RPDs as a potential treatment modality for such patients and explores indications and contraindications for their use, including factors relating to patient history, clinical presentation and patient wishes. Through case examples, design, material and fabrication considerations will be discussed. While their use is not widespread, there are a number of patients who benefit from the provision of unilateral RPDs. They are a useful treatment to have in the clinician's armamentarium, but a highly-skilled dental team and a specific patient presentation is required in order for them to be a reasonable and predictable prosthetic option.

  14. Capability of defective graphene-supported Pd{sub 13} and Ag{sub 13} particles for mercury adsorption

    Energy Technology Data Exchange (ETDEWEB)

    Meeprasert, Jittima; Junkaew, Anchalee; Rungnim, Chompoonut; Kunaseth, Manaschai [National Nanotechnology Center, NSTDA, 111 Thailand Science Park, Klong Luang, Pathum Thani 12120 Thailand (Thailand); Kungwan, Nawee [Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Promarak, Vinich [School of Molecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology, Wangchan, Rayong 21210 (Thailand); Namuangruk, Supawadee, E-mail: supawadee@nanotec.or.th [National Nanotechnology Center, NSTDA, 111 Thailand Science Park, Klong Luang, Pathum Thani 12120 Thailand (Thailand)

    2016-02-28

    Graphical abstract: Defective graphene (DG) supported Ag{sub 13} and Pd{sub 13} nanoparticles acts as sorbents for elementary mercury (Hg{sup 0}) adsorption. Hg is inert to DG surface, but it moderately adsorbs on deposited Ag{sub 13}-DG and strongly adsorbs on deposited Pd{sub 13}-DG. - Highlights: • Pd{sub 13}-DG composite has highest stability. • Pd{sub 13}-DG composite is the most reactive sorbent for Hg{sup 0} adsorption. • Hg{sup 0} adsorption abilities of Pd-DG composites are relatively higher than those of Ag-DG composites. • The d-band center of deposited metal is an adsorption descriptor of composite models. - Abstract: Reactivity of single-vacancy defective graphene (DG) and DG-supported Pd{sub n} and Ag{sub n} (n = 1, 13) for mercury (Hg{sup 0}) adsorption has been studied using density functional theory calculation. The results show that Pd{sub n} binds defective site of DG much stronger than the Ag{sub n}, while metal nanocluster binds DG stronger than single metal atom. Metal clustering affects the adsorption ability of Pd composite while that of Ag is comparatively less. The binding strength of −8.49 eV was found for Pd{sub 13} binding on DG surface, indicating its high stability. Analyses of structure, energy, partial density of states, and d-band center (ε{sub d}) revealed that the adsorbed metal atom or cluster enhances the reactivity of DG toward Hg adsorption. In addition, the Hg adsorption ability of M{sub n}-DG composite is found to be related to the ε{sub d} of the deposited M{sub n}, in which the closer ε{sub d} of M{sub n} to the Fermi level correspond to the higher adsorption strength of Hg on M{sub n}-DG composite. The order of Hg adsorption strength on M{sub n}-DG composite are as follows: Pd{sub 13} (−1.68 eV) >> Ag{sub 13} (−0.67 eV) ∼ Ag{sub 1} (−0.69 eV) > Pd{sub 1} (−0.62 eV). Pd{sub 13}-DG composite is therefore more efficient sorbent for Hg{sup 0} removal in terms of high stability and high adsorption

  15. Magnetic domains and frustration in metallic CePdAl

    Energy Technology Data Exchange (ETDEWEB)

    Lucas, Stefan; Huesges, Zita; Huang, Chien-Lung; Stockert, Oliver [Max Planck Institute CPfS, Dresden (Germany); Fritsch, Veronika; Sakai, Akito [EP 6, Electronic Correlations and Magnetism, University of Augsburg (Germany); Grube, Kai; Taubenheim, Christian; Loehneysen, Hilbert von [Karlsruhe Institute of Technology (Germany)

    2016-07-01

    Magnetic frustration is an exciting topic in condensed matter physics, since it can lead to new ground states of materials, e.g. a spin liquid or spin glass state. Effects of magnetic frustration have been investigated intensively for insulating materials. However, the existence of magnetic frustration in metallic systems is still under debate. CePdAl is a metallic Kondo system, where geometric magnetic frustration arises from the formation of Ce ions on a distorted Kagome lattice. Neutron scattering experiments revealed, that only two thirds of the magnetic Ce moments order antiferromagnetically below T{sub N}=2.7 K, whereas the other third remains mainly disordered. Thermodynamic as well as neutron scattering measurements are presented to verify the existence of partial magnetic frustration in CePdAl. Recently neutron diffraction experiments under magnetic fields applied along two orthogonal directions in the magnetically hard basal plane were performed. They show opposite effects on the magnetic intensity of a selected magnetic domain depending on the field direction with respect to the propagation vector. If this is only an effect of different domain population or also due to a change in magnetic frustration shall be discussed.

  16. Preparation of Bimetallic Pd-Co Nanoparticles on Graphene Support for Use as Methanol Tolerant Oxygen Reduction Electrocatalysts

    Directory of Open Access Journals (Sweden)

    R. N. Singh

    2012-12-01

    Full Text Available Graphene-supported (40-x wt% Pd x wt% Co (0≤x≤13.33 alloys/composites have been prepared by a microwave-assisted polyol reduction method and been investigated for their structural and electrocatalytic properties for the oxygen reduction reaction (ORR in 0.5 M H2SO4 at 298 K. The study demonstrated that the bimetallic Pd-Co composite nanoparticles are, in fact, alloy nanoparticles with fcc crystalline structure. Partial substitution of Pd by Co (from 3.64 to 13.33 wt% in 40 wt% Pd/graphene decreases the lattice parameter as well as the crystallite size and increases the apparent catalytic activity, the latter, however, being the greatest with 8 wt% Co. The ORR activity of the active 32 wt% Pd 8wt% Co is found to be considerably low when it was deposited on the support multiwall carbon nanotubes under similar conditions. The rotating disk electrode study indicated that the ORR on 32 wt% Pd 8 wt% Co/GNS in 0.5 M H2SO4 follows approximately the four-electron pathway.

  17. PD-1/PD-L signaling pathway in chronic hepatitis B

    Directory of Open Access Journals (Sweden)

    TAO Lilin

    2016-12-01

    Full Text Available Hepatitis B is one of the major diseases that affect the health of Chinese people, and chronic hepatitis B virus (HBV infection can lead to disease progression. Programmed death-1 (PD-1 discovered in recent years is an important coordinated stimulus molecule which belongs to the B7/CD28 family. After its binding with programmed death ligand (PD-L, it can regulate the activation, differentiation, and proliferation of T lymphocytes. PD-1 and its ligand are differently expressed in different stages of chronic HBV infection. The interaction between PD-1 and its ligand in different immune cells induces immune tolerance in human body and finally leads to the chronicity of HBV infection. Blocking the PD-1/PD-L signaling pathway through different ways can improve T cell exhaustion, suggesting that this might be one of the directions of antiviral therapy in future.

  18. Tutorial on Online Partial Evaluation

    Directory of Open Access Journals (Sweden)

    William R. Cook

    2011-09-01

    Full Text Available This paper is a short tutorial introduction to online partial evaluation. We show how to write a simple online partial evaluator for a simple, pure, first-order, functional programming language. In particular, we show that the partial evaluator can be derived as a variation on a compositionally defined interpreter. We demonstrate the use of the resulting partial evaluator for program optimization in the context of model-driven development.

  19. Theoretical analysis of hydrogen chemisorption on Pd(111), Re(0001) and PdML/Re(0001), ReML/Pd(111) pseudomorphic overlayers

    DEFF Research Database (Denmark)

    Pallassana, Venkataraman; Neurock, Matthew; Hansen, Lars Bruno

    1999-01-01

    not appear to provide an independent parameter for assessing surface reactivity. The weak chemisorption of hydrogen on the Pd-ML/Re(0001) surface relates to substantial lowering of the d-band center of Pd, when it is pseudomorphically deposited as a monolayer on a Re substrate. [S0163-1829(99)00331-2].......Gradient-corrected density-functional theory (DFT-GGA) periodic slab calculations have been used to analyze the binding of atomic hydrogen on monometallic Pd(111), Re(0001), and bimetallic Pd-mL/Re(0001) [pseudomorphic monolayer of Pd(111) on Re(0001)] and Re-ML/Pd(111) surfaces. The computed...

  20. Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Type-directed partial evaluation uses a normalization function to achieve partial evaluation. These lecture notes review its background, foundations, practice, and applications. Of specific interest is the modular technique of offline and online type-directed partial evaluation in Standard ML...

  1. Type-Directed Partial Evaluation

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Type-directed partial evaluation uses a normalization function to achieve partial evaluation. These lecture notes review its background, foundations, practice, and applications. Of specific interest is the modular technique of offline and online type-directed partial evaluation in Standard ML of ...

  2. Nanostructure analysis of friction welded Pd-Ni-P/Pd-Cu-Ni-P metallic glass interface

    International Nuclear Information System (INIS)

    Ohkubo, T.; Shoji, S.; Kawamura, Y.; Hono, K.

    2005-01-01

    Friction welded Pd 40 Ni 40 P 20 /Pd 40 Cu 30 Ni 10 P 20 metallic glass interface has been characterized by energy filtering transmission electron microscopy. The interface is fully amorphous with a gradual compositional change of Cu and Ni in the range of 30 nm. By annealing above T g , the interdiffusion of Cu and Ni progressed in the supercooled liquid region, and the crystallization occurred from the Pd 40 Ni 40 P 20 glass

  3. Cytotoxicity of Pd nanostructures supported on PEN: Influence of sterilization on Pd/PEN interface

    Energy Technology Data Exchange (ETDEWEB)

    Polívková, M., E-mail: polivkoa@vscht.cz [Department of Solid State Engineering, University of Chemistry and Technology Prague, 166 28 Prague (Czech Republic); Siegel, J. [Department of Solid State Engineering, University of Chemistry and Technology Prague, 166 28 Prague (Czech Republic); Rimpelová, S. [Department of Biochemistry and Microbiology, University of Chemistry and Technology Prague, 166 28 Prague (Czech Republic); Hubáček, T. [Institute of Hydrobiology, Biology Centre of the AS CR, 370 05 Ceske Budejovice (Czech Republic); Kolská, Z. [Materials Centre of Usti n. L., J.E. Purkyne University, 400 96 Usti nad Labem (Czech Republic); Švorčík, V. [Department of Solid State Engineering, University of Chemistry and Technology Prague, 166 28 Prague (Czech Republic)

    2017-01-01

    Non-conventional antimicrobial agents, such as palladium nanostructures, have been increasingly used in the medicinal technology. However, experiences uncovering their harmful and damaging effects to human health have begun to appear. In this study, we have focused on in vitro cytotoxicity assessment of Pd nanostructures supported on a biocompatible polymer. Pd nanolayers of variable thicknesses (ranging from 1.1 to 22.4 nm) were sputtered on polyethylene naphthalate (PEN). These nanolayers were transformed by low-temperature post-deposition annealing into discrete nanoislands. Samples were characterized by AFM, XPS, ICP-MS and electrokinetic analysis before and after annealing. Sterilization of samples prior to cytotoxicity testing was done by UV irradiation, autoclave and/or ethanol. Among the listed sterilization techniques, we have chosen the gentlest one which had minimal impact on sample morphology, Pd dissolution and overall Pd/PEN interface quality. Cytotoxic response of Pd nanostructures was determined by WST-1 cell viability assay in vitro using three model cell lines: mouse macrophages (RAW 264.7) and two types of mouse embryonic fibroblasts (L929 and NIH 3T3). Finally, cell morphology in response to Pd/PEN was evaluated by means of fluorescence microscopy. - Highlights: • Annealing of Pd nanolayers on PEN resulted to Pd aggregation and formation of discrete nanoislands. • UV treatment was found as the gentlest sterilization method in term of physicochemical properties of Pd/PEN interface. • Autoclaving and chemical sterilization by ethanol resulted into remarkable changes of Pd/PEN interface. • Cytotoxicity of Pd samples was insignificant. • Pd nanostructures are potentially applicable as health-unobjectionable antibacterial coatings of medical devices.

  4. Preparation of 103Pd seed-molecular plating of 103Pd onto silver rod

    International Nuclear Information System (INIS)

    Zhang Chunfu; Wang Yongxian; Tian Haibin; Yin Duanzhi

    2002-01-01

    A method for 103 Pd 'molecular plating' onto the surface of a silver rod is reported. The optimal composition of the plating bath is as follows: palladium chloride 0.1 mol/l, formaldehyde 2 mol/l, nitric acid 1 mol/l, and formic acid 0.4 mol/l. The 103 Pd molecular plating procedure will last 25 min at 30 deg. C. This article provides a valuable experience for the preparation of 103 Pd brachytherapy seed

  5. Preparation of 103Pd seeds. Part 2. 'Molecular Plating' of 103Pd onto copper rod

    International Nuclear Information System (INIS)

    Chunfu Zhang; Yongxian Wang; Haibin Tian; Duanzhi Yin

    2002-01-01

    A method for 103 Pd 'molecular plating' onto the surface of the copper rod is reported. The optimal composition of the plating bath was: palladium chloride 2 g/l, ammonium hydroxide (28%) 150 ml/l, sodium hypophosphite 12 g/l, and ammonium chloride 37 g/l. The whole procedure of 103 Pd 'molecular plating' will last 50 minutes at 40 deg C. Valuable experience for the preparation of 103 Pd seeds is provided. (author)

  6. Nonoverlapping roles of PD-1 and FoxP3 in maintaining immune tolerance in a novel autoimmune pancreatitis mouse model.

    Science.gov (United States)

    Zhang, Baihao; Chikuma, Shunsuke; Hori, Shohei; Fagarasan, Sidonia; Honjo, Tasuku

    2016-07-26

    PD-1 (programmed-death 1), an immune-inhibitory receptor required for immune self-tolerance whose deficiency causes autoimmunity with variable severity and tissue specificity depending on other genetic factors, is expressed on activated T cells, including the transcription factor FoxP3(+) Treg cells known to play critical roles in maintaining immune tolerance. However, whether PD-1 expression by the Treg cells is required for their immune regulatory function, especially in autoimmune settings, is still unclear. We found that mice with partial FoxP3 insufficiency developed early-onset lympho-proliferation and lethal autoimmune pancreatitis only when PD-1 is absent. The autoimmune phenotype was rescued by the transfer of FoxP3-sufficient T cells, regardless of whether they were derived from WT or PD-1-deficient mice, indicating that Treg cells dominantly protect against development of spontaneous autoimmunity without intrinsic expression of PD-1. The absence of PD-1 combined with partial FoxP3 insufficiency, however, led to generation of ex-FoxP3 T cells with proinflammatory properties and expansion of effector/memory T cells that contributed to the autoimmune destruction of target tissues. Altogether, the results suggest that PD-1 and FoxP3 work collaboratively in maintaining immune tolerance mostly through nonoverlapping pathways. Thus, PD-1 is modulating the activation threshold and maintaining the balance between regulatory and effector T cells, whereas FoxP3 is sufficient for dominant regulation through maintaining the integrity of the Treg function. We suggest that genetic or environmental factors that even moderately affect the expression of both PD-1 and FoxP3 can cause life-threatening autoimmune diseases by disrupting the T-cell homeostasis.

  7. PD-1/PD-L blockade in gastrointestinal cancers: lessons learned and the road toward precision immunotherapy

    Directory of Open Access Journals (Sweden)

    Junyu Long

    2017-08-01

    Full Text Available Abstract Gastrointestinal (GI malignancies are the most prevalent tumors worldwide, with increasing incidence and mortality. Although surgical resection, chemotherapy, radiotherapy, and molecular targeted therapy have led to significant advances in the treatment of GI cancer patients, overall survival is still low. Therefore, alternative strategies must be identified to improve patient outcomes. In the tumor microenvironment, tumor cells can escape the host immune response through the interaction of PD-1 and PD-L, which inhibits the function of T cells and tumor-infiltrating lymphocytes while increasing the function of immunosuppressive T regulatory cells. The use of an anti-PD-1/PD-L blockade enables reprogramming of the immune system to efficiently identify and kill tumor cells. In recent years, the efficacy of PD-1/PD-L blockade has been demonstrated in many tumors, and this treatment is expected to be a pan-immunotherapy for tumors. Here, we review the signaling pathway underlying the dysregulation of PD-1/PD-L in tumors, summarize the current clinical data for PD-1/PD-L inhibitors in GI malignancies, and discuss road toward precision immunotherapy in relation to PD-1/PD-L blockade. The preliminary data for PD-1/PD-L inhibitors are encouraging, and the precision immunotherapy of PD-1/PD-L inhibitors will be a viable and pivotal clinical strategy for GI cancer therapy.

  8. PD-1/PD-L blockade in gastrointestinal cancers: lessons learned and the road toward precision immunotherapy.

    Science.gov (United States)

    Long, Junyu; Lin, Jianzhen; Wang, Anqiang; Wu, Liangcai; Zheng, Yongchang; Yang, Xiaobo; Wan, Xueshuai; Xu, Haifeng; Chen, Shuguang; Zhao, Haitao

    2017-08-03

    Gastrointestinal (GI) malignancies are the most prevalent tumors worldwide, with increasing incidence and mortality. Although surgical resection, chemotherapy, radiotherapy, and molecular targeted therapy have led to significant advances in the treatment of GI cancer patients, overall survival is still low. Therefore, alternative strategies must be identified to improve patient outcomes. In the tumor microenvironment, tumor cells can escape the host immune response through the interaction of PD-1 and PD-L, which inhibits the function of T cells and tumor-infiltrating lymphocytes while increasing the function of immunosuppressive T regulatory cells. The use of an anti-PD-1/PD-L blockade enables reprogramming of the immune system to efficiently identify and kill tumor cells. In recent years, the efficacy of PD-1/PD-L blockade has been demonstrated in many tumors, and this treatment is expected to be a pan-immunotherapy for tumors. Here, we review the signaling pathway underlying the dysregulation of PD-1/PD-L in tumors, summarize the current clinical data for PD-1/PD-L inhibitors in GI malignancies, and discuss road toward precision immunotherapy in relation to PD-1/PD-L blockade. The preliminary data for PD-1/PD-L inhibitors are encouraging, and the precision immunotherapy of PD-1/PD-L inhibitors will be a viable and pivotal clinical strategy for GI cancer therapy.

  9. Applications of the pharmacokinetic/pharmacodynamic (PK/PD) analysis of antimicrobial agents.

    Science.gov (United States)

    Asín-Prieto, Eduardo; Rodríguez-Gascón, Alicia; Isla, Arantxazu

    2015-05-01

    The alarming increase of resistance against multiple currently available antibiotics is leading to a rapid lose of treatment options against infectious diseases. Since the antibiotic resistance is partially due to a misuse or abuse of the antibiotics, this situation can be reverted when improving their use. One strategy is the optimization of the antimicrobial dosing regimens. In fact, inappropriate drug choice and suboptimal dosing are two major factors that should be considered because they lead to the emergence of drug resistance and consequently, poorer clinical outcomes. Pharmacokinetic/pharmacodynamic (PK/PD) analysis in combination with Monte Carlo simulation allows to optimize dosing regimens of the antibiotic agents in order to conserve their therapeutic value. Therefore, the aim of this review is to explain the basis of the PK/PD analysis and associated techniques, and provide a brief revision of the applications of PK/PD analysis from a therapeutic point-of-view. The establishment and reevaluation of clinical breakpoints is the sticking point in antibiotic therapy as the clinical use of the antibiotics depends on them. Two methodologies are described to establish the PK/PD breakpoints, which are a big part of the clinical breakpoint setting machine. Furthermore, the main subpopulations of patients with altered characteristics that can condition the PK/PD behavior (such as critically ill, elderly, pediatric or obese patients) and therefore, the outcome of the antibiotic therapy, are reviewed. Finally, some recommendations are provided from a PK/PD point of view to enhance the efficacy of prophylaxis protocols used in surgery. Copyright © 2015 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  10. Discharge Planning in Chronic Conditions

    Science.gov (United States)

    McMartin, K

    2013-01-01

    Background Chronically ill people experience frequent changes in health status accompanied by multiple transitions between care settings and care providers. Discharge planning provides support services, follow-up activities, and other interventions that span pre-hospital discharge to post-hospital settings. Objective To determine if discharge planning is effective at reducing health resource utilization and improving patient outcomes compared with standard care alone. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2004, until December 13, 2011. Review Methods Reports, randomized controlled trials, systematic reviews, and meta-analyses with 1 month or more of follow-up and limited to specified chronic conditions were examined. Outcomes included mortality/survival, readmissions and emergency department (ED) visits, hospital length of stay (LOS), health-related quality of life (HRQOL), and patient satisfaction. Results One meta-analysis compared individualized discharge planning to usual care and found a significant reduction in readmissions favouring individualized discharge planning. A second meta-analysis compared comprehensive discharge planning with postdischarge support to usual care. There was a significant reduction in readmissions favouring discharge planning with postdischarge support. However, there was significant statistical heterogeneity. For both meta-analyses there was a nonsignificant reduction in mortality between the study arms. Limitations There was difficulty in distinguishing the relative contribution of each element within the terms “discharge planning” and “postdischarge support.” For most studies, “usual care” was not explicitly described. Conclusions Compared with usual care, there was moderate quality evidence that individualized discharge planning is more effective at reducing readmissions or hospital LOS but not mortality, and very low quality evidence that it is more

  11. Impact of back-gate bias on the hysteresis effect in partially depleted SOI MOSFETs

    International Nuclear Information System (INIS)

    Luo Jie-Xin; Chen Jing; Zhou Jian-Hua; Wu Qing-Qing; Chai Zhan; Yu Tao; Wang Xi

    2012-01-01

    The hysteresis effect in the output characteristics, originating from the floating body effect, has been measured in partially depleted (PD) silicon-on-insulator (SOI) MOSFETs at different back-gate biases. I D hysteresis has been developed to clarify the hysteresis characteristics. The fabricated devices show the positive and negative peaks in the I D hysteresis. The experimental results show that the I D hysteresis is sensitive to the back gate bias in 0.13-μm PD SOI MOSFETs and does not vary monotonously with the back-gate bias. Based on the steady-state Shockley-Read-Hall (SRH) recombination theory, we have successfully interpreted the impact of the back-gate bias on the hysteresis effect in PD SOI MOSFETs. (condensed matter: structural, mechanical, and thermal properties)

  12. Recurrent vaginal discharge in children.

    Science.gov (United States)

    McGreal, Sharon; Wood, Paul

    2013-08-01

    Childhood vaginal discharge remains a frequent reason for referral from primary to secondary care. The Pediatric and Adolescent Gynecology (PAG) service at Kettering General Hospital was established in 1993 and provides a specialized service that meets the needs of children with gynaecological conditions. To investigate recurrent vaginal discharge noting symptomatology, defining pathogens, common and rarer causes, exploring management regimes, and any changes in practice over time. Retrospective review spanning 15 years identifying prepubertal children attending the outpatient PAG clinic with recurrent vaginal discharge. We reviewed the medical notes individually. 110 patients were identified; 85% were referred from primary care. The age distribution was bimodal at four and eight years. Thirty-five percent of our patients were discharged after the initial consultation. The commonest cause of discharge was vulvovaginitis (82%). Other important causes included suspected sexual abuse (5%), foreign body (3%), labial adhesions (3%), vaginal agenesis (2%). 35% of patients were admitted for vaginoscopy. Vaginal discharge is the most common gynecological symptom in prepubertal girls and can cause repeated clinical episodes. Vulvovaginitis is the most common cause and often responds to simple hygiene measures. Awareness of the less common causes of vaginal discharge is essential. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  13. Extreme ultraviolet spectroscopy of low pressure helium microwave driven discharges

    Science.gov (United States)

    Espinho, Susana; Felizardo, Edgar; Tatarova, Elena; Alves, Luis Lemos

    2016-09-01

    Surface wave driven discharges are reliable plasma sources that can produce high levels of vacuum and extreme ultraviolet radiation (VUV and EUV). The richness of the emission spectrum makes this type of discharge a possible alternative source in EUV/VUV radiation assisted applications. However, due to challenging experimental requirements, publications concerning EUV radiation emitted by microwave plasmas are scarce and a deeper understanding of the main mechanisms governing the emission of radiation in this spectral range is required. To this end, the EUV radiation emitted by helium microwave driven plasmas operating at 2.45 GHz has been studied for low pressure conditions. Spectral lines from excited helium atoms and ions were detected via emission spectroscopy in the EUV/VUV regions. Novel data concerning the spectral lines observed in the 23 - 33 nm wavelength range and their intensity behaviour with variation of the discharge operational conditions are presented. The intensity of all the spectral emissions strongly increases with the microwave power delivered to the plasma up to 400 W. Furthermore, the intensity of all the ion spectral emissions in the EUV range decreases by nearly one order of magnitude as the pressure was raised from 0.2 to 0.5 mbar. Work funded by FCT - Fundacao para a Ciencia e a Tecnologia, under Project UID/FIS/50010/2013 and grant SFRH/BD/52412/2013 (PD-F APPLAuSE).

  14. Pd-nanoparticles cause increased toxicity to kiwifruit pollen compared to soluble Pd(II)

    International Nuclear Information System (INIS)

    Speranza, Anna; Leopold, Kerstin; Maier, Marina; Taddei, Anna Rita; Scoccianti, Valeria

    2010-01-01

    In the present study, endpoints including in vitro pollen performance (i.e., germination and tube growth) and lethality were used as assessments of nanotoxicity. Pollen was treated with 5-10 nm-sized Pd particles, similar to those released into the environment by catalytic car exhaust converters. Results showed Pd-nanoparticles altered kiwifruit pollen morphology and entered the grains more rapidly and to a greater extent than soluble Pd(II). At particulate Pd concentrations well below those of soluble Pd(II), pollen grains experienced rapid losses in endogenous calcium and pollen plasma membrane damage was induced. This resulted in severe inhibition and subsequent cessation of pollen tube emergence and elongation at particulate Pd concentrations as low as 0.4 mg L -1 . Particulate Pd emissions related to automobile traffic have been increasing and are accumulating in the environment. This could seriously jeopardize in vivo pollen function, with impacts at an ecosystem level. - Nanoparticulate Pd - which resembles emissions from automobile catalysts - affects pollen to a higher extent than soluble Pd.

  15. Pd-nanoparticles cause increased toxicity to kiwifruit pollen compared to soluble Pd(II)

    Energy Technology Data Exchange (ETDEWEB)

    Speranza, Anna, E-mail: anna.speranza@unibo.i [Dipartimento di Biologia, Universita di Bologna, via Irnerio 42, 40126 Bologna (Italy); Leopold, Kerstin, E-mail: kerstin.leopold@lrz.tu-muenchen.d [Arbeitsgruppe fuer Analytische Chemie, Technische Universitaet Muenchen, Garching (Germany); Maier, Marina, E-mail: marina.maier@ch.tum.d [Arbeitsgruppe fuer Analytische Chemie, Technische Universitaet Muenchen, Garching (Germany); Taddei, Anna Rita, E-mail: artaddei@unitus.i [CIME, Universita della Tuscia, Viterbo (Italy); Scoccianti, Valeria, E-mail: valeria.scoccianti@uniurb.i [Dipartimento di Scienze dell' Uomo, dell' Ambiente e della Natura, Universita di Urbino ' Carlo Bo' , Urbino (Italy)

    2010-03-15

    In the present study, endpoints including in vitro pollen performance (i.e., germination and tube growth) and lethality were used as assessments of nanotoxicity. Pollen was treated with 5-10 nm-sized Pd particles, similar to those released into the environment by catalytic car exhaust converters. Results showed Pd-nanoparticles altered kiwifruit pollen morphology and entered the grains more rapidly and to a greater extent than soluble Pd(II). At particulate Pd concentrations well below those of soluble Pd(II), pollen grains experienced rapid losses in endogenous calcium and pollen plasma membrane damage was induced. This resulted in severe inhibition and subsequent cessation of pollen tube emergence and elongation at particulate Pd concentrations as low as 0.4 mg L{sup -1}. Particulate Pd emissions related to automobile traffic have been increasing and are accumulating in the environment. This could seriously jeopardize in vivo pollen function, with impacts at an ecosystem level. - Nanoparticulate Pd - which resembles emissions from automobile catalysts - affects pollen to a higher extent than soluble Pd.

  16. Recovery of high-purity metallic Pd from Pd(II)-sorbed biosorbents by incineration.

    Science.gov (United States)

    Won, Sung Wook; Lim, Areum; Yun, Yeoung-Sang

    2013-06-01

    This work reports a direct way to recover metallic palladium with high purity from Pd(II)-sorbed polyethylenimine-modified Corynebacterium glutamicum biosorbent using a combined method of biosorption and incineration. This study is focused on the incineration part which affects the purity of recovered Pd. The incineration temperature and the amount of Pd loaded on the biosorbent were considered as major factors in the incineration process, and their effects were examined. The results showed that both factors significantly affected the enhancement of the recovery efficiency and purity of the recovered Pd. SEM-EDX and XRD analyses were used to confirm that Pd phase existed in the ash. As a result, the recovered Pd was changed from PdO to zero-valent Pd as the incineration temperature was increased from 600 to 900°C. Almost 100% pure metallic Pd was recovered with recovery efficiency above 99.0% under the conditions of 900°C and 136.9 mg/g. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Applied partial differential equations

    CERN Document Server

    Logan, J David

    2004-01-01

    This primer on elementary partial differential equations presents the standard material usually covered in a one-semester, undergraduate course on boundary value problems and PDEs. What makes this book unique is that it is a brief treatment, yet it covers all the major ideas: the wave equation, the diffusion equation, the Laplace equation, and the advection equation on bounded and unbounded domains. Methods include eigenfunction expansions, integral transforms, and characteristics. Mathematical ideas are motivated from physical problems, and the exposition is presented in a concise style accessible to science and engineering students; emphasis is on motivation, concepts, methods, and interpretation, rather than formal theory. This second edition contains new and additional exercises, and it includes a new chapter on the applications of PDEs to biology: age structured models, pattern formation; epidemic wave fronts, and advection-diffusion processes. The student who reads through this book and solves many of t...

  18. Inductance loop and partial

    CERN Document Server

    Paul, Clayton R

    2010-01-01

    "Inductance is an unprecedented text, thoroughly discussing "loop" inductance as well as the increasingly important "partial" inductance. These concepts and their proper calculation are crucial in designing modern high-speed digital systems. World-renowned leader in electromagnetics Clayton Paul provides the knowledge and tools necessary to understand and calculate inductance." "With the present and increasing emphasis on high-speed digital systems and high-frequency analog systems, it is imperative that system designers develop an intimate understanding of the concepts and methods in this book. Inductance is a much-needed textbook designed for senior and graduate-level engineering students, as well as a hands-on guide for working engineers and professionals engaged in the design of high-speed digital and high-frequency analog systems."--Jacket.

  19. Fundamental partial compositeness

    CERN Document Server

    Sannino, Francesco

    2016-11-07

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Successful models exist because gauge quantum numbers of Standard Model fermions admit a minimal enough 'square root'. Furthermore, right-handed SM fermions have an SU(2)$_R$-like structure, yielding a custodially-protected composite Higgs. Baryon and lepton numbers arise accidentally. Standard Model fermions acquire mass at tree level, while the Higgs potential and flavor violations are generated by quantum corrections. We further discuss accidental symmetries and other dynamical features stemming from the new strongly interacting scalars. If the same phenomenology can be obtained from models without our elementary scalars, they would reappear as composite states.

  20. Fundamental partial compositeness

    International Nuclear Information System (INIS)

    Sannino, Francesco; Strumia, Alessandro; Tesi, Andrea; Vigiani, Elena

    2016-01-01

    We construct renormalizable Standard Model extensions, valid up to the Planck scale, that give a composite Higgs from a new fundamental strong force acting on fermions and scalars. Yukawa interactions of these particles with Standard Model fermions realize the partial compositeness scenario. Under certain assumptions on the dynamics of the scalars, successful models exist because gauge quantum numbers of Standard Model fermions admit a minimal enough ‘square root’. Furthermore, right-handed SM fermions have an SU(2)_R-like structure, yielding a custodially-protected composite Higgs. Baryon and lepton numbers arise accidentally. Standard Model fermions acquire mass at tree level, while the Higgs potential and flavor violations are generated by quantum corrections. We further discuss accidental symmetries and other dynamical features stemming from the new strongly interacting scalars. If the same phenomenology can be obtained from models without our elementary scalars, they would reappear as composite states.

  1. One-pot synthesis of Pd-Pt@Pd core-shell nanocrystals with enhanced electrocatalytic activity for formic acid oxidation

    KAUST Repository

    Yuan, Qiang

    2014-01-01

    Well-defined Pd-Pt@Pd core-shell nanocrystals with a Pd-Pt alloy core and a conformal Pd shell of ~2-3 nm were directly synthesized through a one-pot, aqueous solution approach without any preformed Pd or Pt seeds. These Pd-Pt@Pd core-shell nanocrystals show an enhanced electrocatalytic activity for formic acid oxidation compared with commercial Pd black. This journal is © 2014 The Royal Society of Chemistry.

  2. Partial oxidation process

    International Nuclear Information System (INIS)

    Najjar, M.S.

    1987-01-01

    A process is described for the production of gaseous mixtures comprising H/sub 2/+CO by the partial oxidation of a fuel feedstock comprising a heavy liquid hydrocarbonaceous fuel having a nickel, iron, and vanadium-containing ash or petroleum coke having a nickel, iron, and vanadium-containing ash, or mixtures thereof. The feedstock includes a minimum of 0.5 wt. % of sulfur and the ash includes a minimum of 5.0 wt. % vanadium, a minimum of 0.5 ppm nickel, and a minimum of 0.5 ppm iron. The process comprises: (1) mixing together a copper-containing additive with the fuel feedstock; wherein the weight ratio of copper-containing additive to ash in the fuel feedstock is in the range of about 1.0-10.0, and there is at least 10 parts by weight of copper for each part by weight of vanadium; (2) reacting the mixture from (1) at a temperature in the range of 2200 0 F to 2900 0 F and a pressure in the range of about 5 to 250 atmospheres in a free-flow refactory lined partial oxidation reaction zone with a free-oxygen containing gas in the presence of a temperature moderator and in a reducing atmosphere to produce a hot raw effluent gas stream comprising H/sub 2/+CO and entrained molten slag; and where in the reaction zone and the copper-containing additive combines with at least a portion of the nickel and iron constituents and sulfur found in the feedstock to produce a liquid phase washing agent that collects and transports at least a portion of the vanadium-containing oxide laths and spinels and other ash components and refractory out of the reaction zone; and (3) separating nongaseous materials from the hot raw effluent gas stream

  3. Legal aspects of thermal discharges

    International Nuclear Information System (INIS)

    Martin, A.J.

    1974-01-01

    An overview of those legal areas which directly affect technical and planning decisions is presented in the form of 2 legal approaches which constrain the indiscriminate release of thermal discharges to receiving waters. One takes the form of private remedies which have traditionally been available to aggrieved parties who are in some way damaged by the harmful discharge. The 2nd approach utilizes the various statutory constraints leading to direct governmental action. It appears that statutory law is playing the prominent role in restricting the temperature to which receiving waters may be raised as a result of such discharges by using effluent limitations and water quality standards. (Water Resour. Abstr.)

  4. An introduction to gas discharges

    CERN Document Server

    Howatson, A M

    2013-01-01

    An Introduction to Gas Discharges: Second Edition aims to provide a compact introduction to the subject of gas discharges, which continues to make both scientific and industrial progress. In this second edition, the author has made minor corrections, rewritten and expanded some sections, used SI units and modernized notions, in hopes of making the book more up to date. Included in the book is a short history of the subject, an introduction that enumerates the types of gas discharges, the fundamental processes, and then moves on to the more specific areas such as the breakdown, the self-sustai

  5. CQI project improves discharge process.

    Science.gov (United States)

    1998-08-01

    At Gibson Rehab Center in Williamsport, PA, a continuous quality improvement project to bolster the institution's discharge planning process has resulted in increased satisfaction and an award for quality. The 15-month project was spearheaded by a multidisciplinary team charged with identifying areas that had a significant impact on customer service and suggesting better ways of delivering that service. Among the changes the group suggested were establishing a weekly discharge planning group for new neuro patients, assigning a discharge coordinator for each treatment team, and creating an interdisciplinary communication sheet for the home health therapy staff.

  6. CO oxidation on PdO surfaces

    DEFF Research Database (Denmark)

    Hirvi, Janne T.; Kinnunen, Toni-Jani J.; Suvanto, Mika

    2010-01-01

    Density functional calculations were performed in order to investigate CO oxidation on two of the most stable bulk PdO surfaces. The most stable PdO(100) surface, with oxygen excess, is inert against CO adsorption, whereas strong adsorption on the stoichiometric PdO(101) surface leads to favorable...... oxidation via the Langmuir–Hinshelwood mechanism. The reaction with a surface oxygen atom has an activation energy of 0.66 eV, which is comparable to the lowest activation energies observed on metallic surfaces. However, the reaction rate may be limited by the coverage of molecular oxygen. Actually...... adsorption, following the Eley–Rideal mechanism and taking advantage of the reaction tunnel provided by the adjacent palladium atom, has an activation energy of only 0.24 eV. The reaction mechanism and activation energy for the palladium activated CO oxidation on the most stable PdO(100)–O surface...

  7. Vaginal itching and discharge - child

    Science.gov (United States)

    Pruritus vulvae; Itching - vaginal area; Vulvar itching; Yeast infection - child ... Common causes of vaginal itching and discharge in young girls include: Chemicals such as perfumes and dyes in detergents, fabric softeners, creams, ointments, ...

  8. Microwave discharges in capillary tubes

    International Nuclear Information System (INIS)

    Dervisevic, Emil

    1984-01-01

    This research thesis aims at being a contribution to the study of microwave discharge by a surface wave, and more precisely focusses on the discharge in capillary tubes filled with argon. The author first present theoretical models which describe, on the one hand, the propagation of the surface wave along the plasma column, and, on the other hand, longitudinal and radial profiles of the main discharge characteristics. The second part addresses the study of the influence of parameters (gas pressure and tube radius) on discharge operation and characteristics. Laws of similitude as well as empirical relationships between argon I and argon II emission line intensities, electron density, and electric field in the plasma have been established [fr

  9. Ion source of discharge type

    Energy Technology Data Exchange (ETDEWEB)

    Enchevich, I.B. [TRIUMF, Cyclotron Div., Vancouver, British Columbia (Canada); Korenev, S.A. [JINR, Hihg Energy Physics Lab., Dubna, Moscow (Russian Federation)

    1992-07-01

    A new scheme of ion source based on a dielectric surface sliding discharge is described. The conditions to form this type of discharge are analyzed and experimental results are shown. The main parameters of this ion source are: accelerating voltage U = 1/20kV; continuous extracted ion beam; current density j = 0.01/0.5 A/cm{sup 2}; ions of Cl, F, C, H; residual gas pressure P = 10{sup -6} Torr. A magnetic system is used to separate the different types of ions. The dielectric material in the discharge circuit (anode plasma emitter) defines the type of ions. The emission characteristics of plasma emitter and the discharge parameters are presented. The ion current yield satisfies the Child-Langmuir law. (author)

  10. Ion source of discharge type

    International Nuclear Information System (INIS)

    Enchevich, I.B.; Korenev, S.A.

    1992-07-01

    A new scheme of ion source based on a dielectric surface sliding discharge is described. The conditions to form this type of discharge are analyzed and experimental results are shown. The main parameters of this ion source are: accelerating voltage U = 1/20kV; continuous extracted ion beam; current density j = 0.01/0.5 A/cm 2 ; ions of Cl, F, C, H; residual gas pressure P = 10 -6 Torr. A magnetic system is used to separate the different types of ions. The dielectric material in the discharge circuit (anode plasma emitter) defines the type of ions. The emission characteristics of plasma emitter and the discharge parameters are presented. The ion current yield satisfies the Child-Langmuir law. (author)

  11. Hospitalization for partial nephrectomy was not associated with intrathecal opioid analgesia: Retrospective analysis.

    Science.gov (United States)

    Weingarten, Toby N; Del Mundo, Serena B; Yeoh, Tze Yeng; Scavonetto, Federica; Leibovich, Bradley C; Sprung, Juraj

    2014-10-01

    The aim of this retrospective study is to test the hypothesis that the use of spinal analgesia shortens the length of hospital stay after partial nephrectomy. We reviewed all patients undergoing partial nephrectomy for malignancy through flank incision between January 1, 2008, and June 30, 2011. We excluded patients who underwent tumor thrombectomy, used sustained-release opioids, or had general anesthesia supplemented by epidural analgesia. Patients were grouped into "spinal" (intrathecal opioid injection for postoperative analgesia) versus "general anesthetic" group, and "early" discharge group (within 3 postoperative days) versus "late" group. Association between demographics, patient physical status, anesthetic techniques, and surgical complexity and hospital stay were analyzed using multivariable logistic regression analysis. Of 380 patients, 158 (41.6%) were discharged "early" and 151 (39.7%) were "spinal" cases. Both spinal and early discharge groups had better postoperative pain control and used less postoperative systemic opioids. Spinal analgesia was associated with early hospital discharge, odds ratio 1.52, (95% confidence interval 1.00-2.30), P = 0.05, but in adjusted analysis was no longer associated with early discharge, 1.16 (0.73-1.86), P = 0.52. Early discharge was associated with calendar year, with more recent years being associated with early discharge. Spinal analgesia combined with general anesthesia was associated with improved postoperative pain control during the 1(st) postoperative day, but not with shorter hospital stay following partial nephrectomy. Therefore, unaccounted practice changes that occurred during more recent times affected hospital stay.

  12. Radioactive discharges from Sellafield (UK)

    International Nuclear Information System (INIS)

    Pentreath, R.J.

    1985-01-01

    This study of low-level liquid radioactive discharges from the British Nuclear Fuels Ltd Sellafield site into the eastern basin of the Irish Sea, prepared on the basis of existing publications and documents, reviews chemical forms and rate of discharges, physical oceanography, sediment distribution and fisheries of the Irish Sea, behaviour of radionuclides in seawater, association with sedimentary materials, accumulation of radionuclides by biological materials, environmental monitoring, surveillance and assessment of radiation exposure of the public and impact on the environment

  13. Chronic obstructive pulmonary disease - adults - discharge

    Science.gov (United States)

    ... coughing up dark mucus Your fingertips or the skin around your fingernails are blue Alternative Names COPD - adults - discharge; Chronic obstructive airways disease - adults - discharge; Chronic obstructive lung disease - adults - discharge; ...

  14. Combined SEP and anti-PD-L1 antibody produces a synergistic antitumor effect in B16-F10 melanoma-bearing mice.

    Science.gov (United States)

    Hu, Zhengping; Ye, Liang; Xing, Yingying; Hu, Jinhang; Xi, Tao

    2018-01-09

    The increased PD-L1 induces poorer prognosis in melanoma. The treatment with PD-1/PD-L1 antibodies have a low response rate. The combination immunotherapies are the encouraging drug development strategy to receive maximal therapeutic benefit. In this study, we investigated the enhanced antitumor and immunomodulatory activity of combined SEP and αPD-L1 in B16-F10 melanoma-bearing mice. The results shown that combined SEP and αPD-L1 presented significant synergistic antitumor effects, increased the frequency of CD8 + and CD4 + T cells in spleen and tumor, cytotoxic activity of CTL in spleen, and IL-2 and IFN-γ levels in splenocytes and tumor. The combination treatment also produced synergistic increase in P-ERK1/2 level in spleen. Immunohistochemistry shown that SEP induced the PD-L1 expression in melanoma tissue possibly by promoting IFN-γ excretion, which led to the synergistic anti-tumor effects of aPD-L1 and SEP. Furthermore, in the purified T lymphocyte from the naive mice, the combination of SEP and αPD-L1 had more potent than SEP or αPD-L1 in promoting T lymphocyte proliferation and cytokines secretion including IL-2 and IFN-γ, at least partially by activating MEK/ERK pathway. Our study provides the scientific basis for a clinical trial that would involve combination of anti-PD-L1 mAb and SEP for sustained melanoma control.

  15. Ballooning stability of JET discharges

    International Nuclear Information System (INIS)

    Huysmans, G.T.A.; Goedbloed, J.P.; Galvao, R.M.O.; Lazzaro, E.; Smeulders, P.

    1989-01-01

    Conditions under which ballooning modes are expected to be excited have recently been obtained in two different types of discharges in JET. In the first type, extremely large pressure gradients have been produced in the plasma core through pellet injections in the current rise phase followed by strong additional heating. In the second type, the total pressure of the discharge is approaching the Troyon limit. The stability of these discharges with respect to the ideal MHD ballooning modes has been studied with the stability code HBT. The equilibria are reconstructed with the IDENTC code using the external magnetic measurements and the experimental pressure profile. The results show that the evaluated high beta discharge is unstable in the central region of the plasma. This instability is related to the low shear and not to a large pressure gradient, as expected at the Troyon limit. In the pellet discharges the regions with the large pressure gradients are unstable to ballooning modes at the time of the beta decay, which ends the period of enhanced performance. The maximum pressure gradient in these discharges is limited by the boundary of the first region of stability. The observed phenomena at the beta decay are similar to those observed at the beta limit in DIII-D and TFTR. (author)

  16. Filamentary and diffuse barrier discharges

    International Nuclear Information System (INIS)

    Kogelschatz, U.

    2001-01-01

    Barrier discharges, sometimes also referred to as dielectric-barrier discharges or silent discharges, are characterized by the presence of at least one insulating layer in contact with the discharge between two planar or cylindrical electrodes connected to an ac power supply. The main advantage of this type of electrical discharge is, that non-equilibrium plasma conditions in atmospheric-pressure gases can be established in an economic and reliable way. This has led to a number of important applications including industrial ozone generation, surface modification of polymers, plasma chemical vapor deposition, excitation of CO 2 lasers, excimer lamps and, most recently, large-area flat plasma display panels. Depending on the application, the width of the discharge gap can range from less than 0.1 mm to about 100 mm and the applied frequency from below line frequency to several gigahertz. Typical materials used for the insulating layer (dielectric barrier) are glass, quartz, ceramics but also thin enamel or polymer layers

  17. Bimetallic magnetic PtPd-nanoparticles as efficient catalyst for PAH removal from liquid media

    Science.gov (United States)

    Zanato, A. F. S.; Silva, V. C.; Lima, D. A.; Jacinto, M. J.

    2017-11-01

    Monometallic Pd- and bimetallic PtPd-nanoparticles supported on a mesoporous magnetic magnetite@silica matrix resembling a core-shell structure (Fe3O4@mSiO2) have been fabricated. The material was characterized by transmission electron microscope (TEM), high-angle annular dark field-scanning transmission electron microscopy (HAADF-STEM), X-ray photoelectron spectra (XPS), energy dispersive spectroscopy (EDS) and inductively coupled plasma mass spectrometry (ICP-MS). The catalysts were applied in the removal of anthracene from liquid phase via catalytic hydrogenation. It was found that anthracene as a model compound could be completely converted into the partially hydrogenated species by the monometallic and bimetallic solids. However, during the recycling study the bimetallic material (Fe3O4@mSiO2PtPd-) showed an enhanced activity towards anthracene removal compared with the monometallic materials. A single portion of the PtPd-based catalyst can be used up to 11 times in the hydrogenation of anthracene under mild conditions (6 atm of H2, 75 °C, 20 min). Thanks to the presence of a dense magnetic core, the catalysts were capable of responding to an applied external magnetic field and once the reaction was completed, catalyst/product separation was straightforward.

  18. Discharge cleaning on KSTAR 1st plasma events

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, J. G.; Wang, J. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, J. S.; Yang, H. L.; Kim, K. P.; Kim, K. M. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2008-10-15

    A discharge cleaning of a vacuum vessel was conducted with a GDC (Glow discharge cleaning) and a ICRF-DC(ICRF assisted discharge cleaning) for the KSTAR first plasma event period. The base pressure of the vessel was kept below 10-7 mbar via a cool down of the cryo-vessel, a 100C baking, and a GDC. (Partial pressure of hydrogen and nitrogen is below 10-8 mbar). The diagnostics for a discharge cleaning is a differential pumped RGA attached to a pumping duct and a cold cathode and a hot cathode gauge attached to the vessel and the pumping duct respectively. To analyze the discharge characteristics, a microwave interferometer, Bremsstahlung, H-alphas and a TV camera were used. Two straps among the four straps of the ICRF antenna are used for the ICRF-DC and ICRF heating experiments. The phase difference between the adjacent straps was 0 degree and the operating frequency was 30-33MHz.

  19. Experts' understanding of partial derivatives using the Partial Derivative Machine

    OpenAIRE

    Roundy, David; Dorko, Allison; Dray, Tevian; Manogue, Corinne A.; Weber, Eric

    2014-01-01

    Partial derivatives are used in a variety of different ways within physics. Most notably, thermodynamics uses partial derivatives in ways that students often find confusing. As part of a collaboration with mathematics faculty, we are at the beginning of a study of the teaching of partial derivatives, a goal of better aligning the teaching of multivariable calculus with the needs of students in STEM disciplines. As a part of this project, we have performed a pilot study of expert understanding...

  20. Development of 103Pd preparation

    International Nuclear Information System (INIS)

    Tri Murni

    2003-01-01

    Development of 1 03 P d preparation. Radioisotope of 1 03 P d was prepared for medical purpose patient suffering prostate cancer at early stage for therapeutic treatment. In the form of seed, the 1 03 P d radioisotope as a curing agent for prostate cancer is the most effective form with the least side effect. Radioisotope of 1 03 P d is the radioisotope emitting γ of 357 keV. In this investigation 1 03 P d was prepared from natural Pd powder or 1 02 P d enriched bombarded using thermal neutron in the reactor with 1 02 P d( n, γ) 1 03 P d reaction and 1 03 P d radioisotope was obtained. The target was then added with hydrogen peroxide after a with 1N HCl was added followed by drying . Then 2N NH 4 OH was added until the pH of the solution reached 8-10. In every steps of the process, the analysis were performed using MCA while the radiochemical purity were analyses using paper chromatography. The end result of the dissolution process showed that it is an accord with 1 03 P dCl 2 in NH 4 OH solution specification of Nordion

  1. Classification of electrical discharges in DC Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Srutarshi, E-mail: sruban.stephens@gmail.com [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Deb, A.K. [Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302 (India); Rajan, Rehim N. [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Kishore, N.K. [Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302 (India)

    2016-08-11

    Controlled electrical discharge aids in conditioning of the system while uncontrolled discharges damage its electronic components. DC Accelerator being a high voltage system is no exception. It is useful to classify electrical discharges according to the severity. Experimental prototypes of the accelerator discharges are developed. Photomultiplier Tubes (PMTs) are used to detect the signals from these discharges. Time and Frequency domain characteristics of the detected discharges are used to extract features. Machine Learning approaches like Fuzzy Logic, Neural Network and Least Squares Support Vector Machine (LSSVM) are employed to classify the discharges. This aids in detecting the severity of the discharges.

  2. Safety and Activity of Anti–PD-L1 Antibody in Patients with Advanced Cancer

    Science.gov (United States)

    Brahmer, Julie R.; Tykodi, Scott S.; Chow, Laura Q.M.; Hwu, Wen-Jen; Topalian, Suzanne L.; Hwu, Patrick; Drake, Charles G.; Camacho, Luis H.; Kauh, John; Odunsi, Kunle; Pitot, Henry C.; Hamid, Omid; Bhatia, Shailender; Martins, Renato; Eaton, Keith; Chen, Shuming; Salay, Theresa M.; Alaparthy, Suresh; Grosso, Joseph F.; Korman, Alan J.; Parker, Susan M.; Agrawal, Shruti; Goldberg, Stacie M.; Pardoll, Drew M.; Gupta, Ashok; Wigginton, Jon M.

    2013-01-01

    BACKGROUND Programmed death 1 (PD-1) protein, a T-cell coinhibitory receptor, and one of its ligands, PD-L1, play a pivotal role in the ability of tumor cells to evade the host’s immune system. Blockade of interactions between PD-1 and PD-L1 enhances immune function in vitro and mediates antitumor activity in preclinical models. METHODS In this multicenter phase 1 trial, we administered intravenous anti–PD-L1 antibody (at escalating doses ranging from 0.3 to 10 mg per kilogram of body weight) to patients with selected advanced cancers. Anti–PD-L1 antibody was administered every 14 days in 6-week cycles for up to 16 cycles or until the patient had a complete response or confirmed disease progression. RESULTS As of February 24, 2012, a total of 207 patients — 75 with non–small-cell lung cancer, 55 with melanoma, 18 with colorectal cancer, 17 with renal-cell cancer, 17 with ovarian cancer, 14 with pancreatic cancer, 7 with gastric cancer, and 4 with breast cancer — had received anti–PD-L1 antibody. The median duration of therapy was 12 weeks (range, 2 to 111). Grade 3 or 4 toxic effects that investigators considered to be related to treatment occurred in 9% of patients. Among patients with a response that could be evaluated, an objective response (a complete or partial response) was observed in 9 of 52 patients with melanoma, 2 of 17 with renal-cell cancer, 5 of 49 with non–small-cell lung cancer, and 1 of 17 with ovarian cancer. Responses lasted for 1 year or more in 8 of 16 patients with at least 1 year of follow-up. CONCLUSIONS Antibody-mediated blockade of PD-L1 induced durable tumor regression (objective response rate of 6 to 17%) and prolonged stabilization of disease (rates of 12 to 41% at 24 weeks) in patients with advanced cancers, including non–small-cell lung cancer, melanoma, and renal-cell cancer. (Funded by Bristol-Myers Squibb and others; ClinicalTrials.gov number, NCT00729664.) PMID:22658128

  3. Successful treatment of dopamine dysregulation syndrome with dopamine D2 partial agonist antipsychotic drug

    Directory of Open Access Journals (Sweden)

    Mizushima Jin

    2012-07-01

    Full Text Available Abstract Dopamine dysregulation syndrome (DDS consists of a series of complications such as compulsive use of dopaminergic medications, aggressive or hypomanic behaviors during excessive use, and withdrawal states characterized by dysphoria and anxiety, caused by long-term dopaminergic treatment in patients with Parkinson’s disease (PD. Although several ways to manage DDS have been suggested, there has been no established treatment that can manage DDS without deterioration of motor symptoms. In this article, we present a case of PD in whom the administration of the dopamine D2 partial agonistic antipsychotic drug aripiprazole improved DDS symptoms such as craving and compulsive behavior without worsening of motor symptoms. Considering the profile of this drug as a partial agonist at D2 receptors, it is possible that it exerts its therapeutic effect on DDS by modulating the dysfunctional dopamine system.

  4. CO tolerance of PdPt/C and PdPtRu/C anodes for PEMFC

    International Nuclear Information System (INIS)

    Garcia, Amanda C.; Paganin, Valdecir A.; Ticianelli, Edson A.

    2008-01-01

    The performance of H 2 /O 2 proton exchange membrane fuel cells (PEMFCs) fed with CO-contaminated hydrogen was investigated for anodes with PdPt/C and PdPtRu/C electrocatalysts. The physicochemical properties of the catalysts were characterized by energy dispersive X-ray (EDX) analyses, X-ray diffraction (XRD) and 'in situ' X-ray absorption near edge structure (XANES). Experiments were conducted in electrochemical half and single cells by cyclic voltammetry (CV) and I-V polarization measurements, while DEMS was employed to verify the formation of CO 2 at the PEMFC anode outlet. A quite high performance was achieved for the PEMFC fed with H 2 + 100 ppm CO with the PdPt/C and PdPtRu/C anodes containing 0.4 mg metal cm -2 , with the cell presenting potential losses below 200 mV at 1 A cm -2 , with respect to the system fed with pure H 2 . For the PdPt/C catalysts no CO 2 formation was seen at the PEMFC anode outlet, indicating that the CO tolerance is improved due to the existence of more free surface sites for H 2 electrooxidation, probably due to a lower Pd-CO interaction compared to pure Pd or Pt. For PdPtRu/C the CO tolerance may also have a contribution from the bifunctional mechanism, as shown by the presence of CO 2 in the PEMFC anode outlet

  5. Progress of PD-1/PD-L1 Inhibitors in Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Zhansheng JIANG

    2017-02-01

    Full Text Available Pembrolizumab, an inhibitor target programmed death 1 (PD-1, was approved into the first line therapy in advanced non-small cell lung cancer (NSCLC. It was a milestone that immune checkpoints drugs have played an important role in the treatment system of NSCLC. The results of clinical trials revealed the superiority of PD-1/programmed death ligand 1 (PD-L1 inhibitors compared with chemotherapy in first-line, second-line and multidrug resistance phase therapy. Objective response rate (ORR was up to 80% with pembrolizumab plus chemotherapy, and progression-free survival (PFS with single pembrolizumab in first line was nearly 1 year (10.3 months, the hazard ratio for death fell by 40%. Overall survival (OS was more or less 1 year with single drug pembrolizumab, nivolumab and atezolizumab for second line therapy. PD-L1 expression was a predictor of PD-1/PD-L1 inhibitors. The positive rate of PD-L1 (more than 1% in advanced NSCLC was about 60% with little difference between the tissue types. However, there was no gold standard test of PD-L1 expression.

  6. Measurement of benzenethiol adsorption to nanostructured Pt, Pd, and PtPd films using Raman spectroelectrochemistry.

    Science.gov (United States)

    Pomfret, Michael B; Pietron, Jeremy J; Owrutsky, Jeffrey C

    2010-05-04

    Raman spectroscopy and electrochemical methods were used to study the behavior of the model adsorbate benzenethiol (BT) on nanostructured Pt, Pd, and PtPd electrodes as a function of applied potential. Benzenethiol adsorbs out of ethanolic solutions as the corresponding thiolate, and voltammetric stripping data reveal that BT is oxidatively removed from all of the nanostructured metals upon repeated oxidative and reductive cycling. Oxidative stripping potentials for BT increase in the order Pt oxidizing potentials via cleavage of the Pt-S bond. In contrast, on nanoscale Pd and PtPd, BT is irreversibly lost due to cleavage of BT C-S bonds at oxidizing potentials, which leaves adsorbed sulfur oxides on Pd and PtPd films and effects the desulfurization of BT. While Pd and PtPd films are less sulfur-resistant than Pt films, palladium oxides, which form at higher potentials than Pt oxides, oxidatively desulfurize BT. In situ spectroelectrochemical Raman spectroscopy provides real-time, chemically specific information that complements the cyclic voltammetric data. The combination of these techniques affords a powerful and convenient method for guiding the development of sulfur-tolerant PEMFC catalysts.

  7. Preparation of supported Au–Pd and Cu–Pd by the combined strong ...

    Indian Academy of Sciences (India)

    BOONTIDA PONGTHAWORNSAKUN

    2017-10-25

    Oct 25, 2017 ... Bimetallic catalyst; Au–Pd/TiO2; Cu–Pd/TiO2; strong electrostatic adsorption; electroless deposition .... The liquid samples .... composition and gas mixture product at the outlet of reactor ... the TiO2 support (no change in the deposition curve of. TiO2). ..... TrimmDL1980In Design of Industrial Catalysts (Ams-.

  8. Investigation of electronic structure and chemical bonding of intermetallic Pd2HfIn: An ab-initio study

    Science.gov (United States)

    Bano, Amreen; Gaur, N. K.

    2018-05-01

    Ab-initio calculations are carried out to study the electronic and chemical bonding properties of Intermetallic full Heusler compound Pd2HfIn which crystallizes in F-43m structure. All calculations are performed by using density functional theory (DFT) based code Quantum Espresso. Generalized gradient approximations (GGA) of Perdew- Burke- Ernzerhof (PBE) have been adopted for exchange-correlation potential. Calculated electronic band structure reveals the metallic character of the compound. From partial density of states (PDoS), we found the presence of relatively high intensity electronic states of 4d-Pd atom at Fermi level. We have found a pseudo-gap just abouve the Fermi level and N(E) at Fermi level is observed to be 0.8 states/eV, these finding indicates the existence of superconducting character in Pd2HfIn.

  9. Domain structures and magnetization reversal in Co/Pd and CoFeB/Pd multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Sbiaa, R., E-mail: rachid@squ.edu.om [Department of Physics, Sultan Qaboos University, P.O. Box 36, PC 123 (Oman); Ranjbar, M. [Physics Department, University of Gothenburg, 412 96 Gothenburg (Sweden); Åkerman, J. [Physics Department, University of Gothenburg, 412 96 Gothenburg (Sweden); Materials Physics, School of ICT, Royal Institute of Technology (KTH), 164 40 Kista (Sweden)

    2015-05-07

    Domain structures and magnetization reversal of (Co/Pd) and (CoFeB/Pd) multilayers with 7 and 14 repeats were investigated. The Co-based multilayers show much larger coercivities, a better squareness, and a sharper magnetization switching than CoFeB-based multilayers. From magnetic force microscopy observations, both structures show strong reduction in domains size as the number of repeats increases but the magnetic domains for Co-based multilayers are more than one order of magnitude larger than for CoFeB-based multilayers. By imaging domains at different times, breaks in the (CoFeB/Pd) multilayer stripes were observed within only few hours, while no change could be seen for (Co/Pd) multilayers. Although CoFeB single layers are suitable for magnetoresistive devices due to their large spin polarization and low damping constants, their lamination with Pd suffers mainly from thermal instability.

  10. Metal-semiconductor transition at a comparable resistivity level and positive magnetoresistance in Mn3Mn1-x Pd x N thin films

    Science.gov (United States)

    Xu, T.; Ji, G. P.; Cao, Z. X.; Ji, A. L.

    2018-02-01

    Thin films of antiperovskite Mn3Mn1-x Pd x N with x up to 0.36 were grown by reactive magnetron co-sputtering method. All the deposits exhibit a [1 0 0] preferential orientation, with the lattice constant slightly enlarged in samples with ever more Pd atoms partially substituting the MnI atoms in Mn3MnN matrix. The replacement of MnI atoms in antiperovskite structure by Pd atoms, besides reducing the saturation magnetization, also invokes a metal-semiconductor transition which occurs remarkably at a comparable resistivity level. Moreover, a positive magnetoresistance was observed in samples of a high Pd content. These tunable electrical and magnetic properties of ternary antiperovskite compounds might promise some ingenious applications in electronic industry.

  11. Partial Actions and Power Sets

    Directory of Open Access Journals (Sweden)

    Jesús Ávila

    2013-01-01

    Full Text Available We consider a partial action (X,α with enveloping action (T,β. In this work we extend α to a partial action on the ring (P(X,Δ,∩ and find its enveloping action (E,β. Finally, we introduce the concept of partial action of finite type to investigate the relationship between (E,β and (P(T,β.

  12. Algorithms over partially ordered sets

    DEFF Research Database (Denmark)

    Baer, Robert M.; Østerby, Ole

    1969-01-01

    in partially ordered sets, answer the combinatorial question of how many maximal chains might exist in a partially ordered set withn elements, and we give an algorithm for enumerating all maximal chains. We give (in § 3) algorithms which decide whether a partially ordered set is a (lower or upper) semi......-lattice, and whether a lattice has distributive, modular, and Boolean properties. Finally (in § 4) we give Algol realizations of the various algorithms....

  13. Magnetic characteristics of CoPd and FePd antidot arrays on nanoperforated Al2O3 templates

    Science.gov (United States)

    Maximenko, A.; Fedotova, J.; Marszałek, M.; Zarzycki, A.; Zabila, Y.

    2016-02-01

    Hard magnetic antidot arrays show promising results in context of designing of percolated perpendicular media. In this work the technology of magnetic FePd and CoPd antidot arrays fabrication is presented and correlation between surface morphology, structure and magnetic properties is discussed. CoPd and FePd antidot arrays were fabricated by deposition of Co/Pd and Fe/Pd multilayers (MLs) on porous anodic aluminum oxide templates with bowl-shape cell structure with inclined intercellular regions. FePd ordered L10 structure was obtained by successive vacuum annealing at elevated temperatures (530 °C) and confirmed by XRD analysis. Systematic analysis of magnetization curves evidenced perpendicular magnetic anisotropy of CoPd antidot arrays, while FePd antidot arrays revealed isotropic magnetic anisotropy with increased out-of-plane magnetic contribution. MFM images of antidots showed more complicated contrast, with alternating magnetic dots oriented parallel and antiparallel to tip magnetization moment.

  14. Generation and oxidation of aerosol deposited PdAg nanoparticles

    Science.gov (United States)

    Blomberg, S.; Gustafson, J.; Martin, N. M.; Messing, M. E.; Deppert, K.; Liu, Z.; Chang, R.; Fernandes, V. R.; Borg, A.; Grönbeck, H.; Lundgren, E.

    2013-10-01

    PdAg nanoparticles with a diameter of 10 nm have been generated by an aerosol particle method, and supported on a silica substrate. By using a combination of X-ray Energy Dispersive Spectroscopy and X-ray Photoelectron Spectroscopy it is shown that the size distribution of the particles is narrow and that the two metals form an alloy with a mixture of 75% Pd and 25% Ag. Under oxidizing conditions, Pd is found to segregate to the surface and a thin PdO like oxide is formed similar to the surface oxide previously reported on extended PdAg and pure Pd surfaces.

  15. Anatomic partial nephrectomy: technique evolution.

    Science.gov (United States)

    Azhar, Raed A; Metcalfe, Charles; Gill, Inderbir S

    2015-03-01

    Partial nephrectomy provides equivalent long-term oncologic and superior functional outcomes as radical nephrectomy for T1a renal masses. Herein, we review the various vascular clamping techniques employed during minimally invasive partial nephrectomy, describe the evolution of our partial nephrectomy technique and provide an update on contemporary thinking about the impact of ischemia on renal function. Recently, partial nephrectomy surgical technique has shifted away from main artery clamping and towards minimizing/eliminating global renal ischemia during partial nephrectomy. Supported by high-fidelity three-dimensional imaging, novel anatomic-based partial nephrectomy techniques have recently been developed, wherein partial nephrectomy can now be performed with segmental, minimal or zero global ischemia to the renal remnant. Sequential innovations have included early unclamping, segmental clamping, super-selective clamping and now culminating in anatomic zero-ischemia surgery. By eliminating 'under-the-gun' time pressure of ischemia for the surgeon, these techniques allow an unhurried, tightly contoured tumour excision with point-specific sutured haemostasis. Recent data indicate that zero-ischemia partial nephrectomy may provide better functional outcomes by minimizing/eliminating global ischemia and preserving greater vascularized kidney volume. Contemporary partial nephrectomy includes a spectrum of surgical techniques ranging from conventional-clamped to novel zero-ischemia approaches. Technique selection should be tailored to each individual case on the basis of tumour characteristics, surgical feasibility, surgeon experience, patient demographics and baseline renal function.

  16. Partial order infinitary term rewriting

    DEFF Research Database (Denmark)

    Bahr, Patrick

    2014-01-01

    We study an alternative model of infinitary term rewriting. Instead of a metric on terms, a partial order on partial terms is employed to formalise convergence of reductions. We consider both a weak and a strong notion of convergence and show that the metric model of convergence coincides with th...... to the metric setting -- orthogonal systems are both infinitarily confluent and infinitarily normalising in the partial order setting. The unique infinitary normal forms that the partial order model admits are Böhm trees....

  17. Glow discharge in singlet oxygen

    International Nuclear Information System (INIS)

    Vagin, N.P.; Ionin, A.A.; Klimachev, Yu.M.; Sinitsyn, D.V.; Yuryshev, N.N.; Kochetov, I.V.; Napartovich, A.P.

    2003-01-01

    Currently, there is no experimental data on the plasma balance in gas mixtures with a high content of singlet delta oxygen O 2 ( 1 Δ g ). These data can be obtained by studying the parameters of an electric discharge in singlet oxygen produced by a chemical generator. The O 2 ( 1 Δ g ) molecules significantly change the kinetics of electrons and negative ions in plasma. Hence, the discharge conditions at low and high O 2 ( 1 Δ g ) concentrations are very different. Here, the parameters of the positive column of a glow discharge in a gas flow from a chemical singlet-oxygen generator are studied. It is experimentally shown that, at an O 2 ( 1 Δ g ) concentration of 50% and at pressures of 1.5 and 2 torr, the electric field required to sustain the discharge is considerably lower than in the case when all of the oxygen molecules are in the ground state. A theoretical model of the glow discharge is proposed whose predictions are in good agreement with the experimental data

  18. PD-1 checkpoint inhibition: Toxicities and management.

    Science.gov (United States)

    Hahn, Andrew W; Gill, David M; Agarwal, Neeraj; Maughan, Benjamin L

    2017-12-01

    With the recent approval of 5 PD-1/PD-L1 inhibitors for a number of malignancies, PD-1 axis inhibition is drastically changing the treatment landscape of immunotherapy in cancer. As PD-1/PD-L1 are involved in peripheral immune tolerance, inhibition of this immune checkpoint has led to novel immune-related adverse events including colitis, hepatitis, pneumonitis, rash, and endocrinopathies among many others. In this seminar, we will analyze the incidence of immune-related adverse events for nivolumab, pembrolizumab, atezolizumab, durvalumab, and avelumab. Then, we will discuss the specific management of the most common immune-mediated adverse events including colitis, hepatitis, pneumonitis, rash, endocrinopathies, nephritis, and neurologic toxicities. Immune-related adverse events are frequently treated with immunosuppressive medication such as steroids and mycofenolate mofetil. There are specific immune-related adverse events which are frequently seen by the treating oncologist from checkpoint inhibitors. It is essential to understand the recommended treatment options to minimize toxicity and mortality from this important class of anti-neoplastic therapies. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Electron runaway in rf discharges

    International Nuclear Information System (INIS)

    Chen, F.F.

    1992-10-01

    The critical electric field is computed as a function of pressure and starting energy for electrons to run away to high energies in moderate pressure discharges. The runaway conditions depend critically on the shape of the elastic cross section vs. energy curve. Computations are made for H, H 2 , and He gases, and it is shown that runaway occurs much more readily in atomic hydrogen than in the other gases. The values of the runaway fields are larger than would normally occur in dc discharges, where large voltages would lead to arc formation. However, in rf discharges such electric fields can be sustained over times long compared to electron transit times but short compared to ion transit times. (author)

  20. Discharge quenching circuit for counters

    International Nuclear Information System (INIS)

    Karasik, A.S.

    1982-01-01

    A circuit for quenching discharges in gas-discharge detectors with working voltage of 3-5 kV based on transistors operating in the avalanche mode is described. The quenching circuit consists of a coordinating emitter follower, amplifier-shaper for avalanche key cascade control which changes potential on the counter electrodes and a shaper of discharge quenching duration. The emitter follower is assembled according to a widely used flowsheet with two transistors. The circuit permits to obtain a rectangular quenching pulse with front of 100 ns and an amplitude of up to 3.2 kV at duration of 500 μm-8 ms. Application of the quenching circuit described permits to obtain countering characteristics with the slope less than or equal to 0.02%/V and plateau extent greater than or equal to 300 V [ru

  1. Pengaruh Karakteristik Budaya Organisasi, Locus of Control dan Disiplin Kerja Terhadap Kinerja Karyawan Studi Pada Perusahaan Daerah Pengelola Air Limbah (PD PAL Kota Banjarmasin.

    Directory of Open Access Journals (Sweden)

    Dessy Rosiana

    2016-09-01

    Full Text Available This research was aimed to simultaneously analyze the significantly positive effect of organizational culture characteristics, locus of control and work discipline towards employee performance at PD PAL Banjarmasin; also to partially analyze the significantly positive effect of organizational culture characteristics, locus of control, and work discipline towards employee performance at PD PAL Banjarmasin. The type of this research was explanatory research. All population became the samples in this research. The information collection of 53 employees who acted as the respondents in this research was done by using questionnaire arranged in 5 Likert Scale. The data analysis used multiple linear regression analysis, multiple determination coefficient, as well as F test and t test. The result of this research showed that the variable of organizational culture characteristics, locus of control and work discipline simultaneously has a significantly positive effect towards employee performance at PD PAL Banjarmasin. The organizational culture characteristics partially does not  have a positive and significant effect towards employee performance. Partially   the locus control has a significantly positive effect towards employee performance. Work discipline partially has a significantly positive effect towards employee performance. The implication to the management, based on the result of this research, is (1 the implementation of the organizational culture characteristics needs to be socialized among employee of PD PAL, and (2 a strong control on the locus control and discipline is needed to improve the employee performance. Keywords: Organizational Culture Characteristics, Locus of Control, Work Discipline, Employee Performance

  2. EFFECTS OF DEXAMETHASONE AND PHENIRAMINE MALEATE ON HEMODYNAMIC AND RESPIRATORY PARAMETERS AFTER CEMENTATION IN CEMENTED PARTIAL HIP PROSTHESIS.

    Science.gov (United States)

    Yektaş, Abdulkadir; Gümüş, Funda; Totoz, Tolga; Gül, Nurten; Erkalp, Kerem; Alagöl, Ayşin

    2015-02-01

    To prevent hemodynamic and respiratory changes that are likely to occur during cementation in partial hip prosthesis by prophylactic use of pheniramine maleate and dexamethasone. The study included 40 patients aged between 60 and 85 years with an American Society ofAnesthesiologists (ASA) grade of II-III who underwent partial hip prosthesis. Just after spinal anesthesia, 4 mL normal saline was pushed in patients in Group S, whereas 45.5 mg pheniramine maleate and 8 mg dexamethasone mixture was pushed intravenously in a total volume of 4 mL in patients in Group PD. Amounts of atropine and adrenaline administered after cementation were significantly higher in Group S than in Group PD (P pheniramine maleate and dexamethasone in partial hip prosthesis led to an increase in SpO2 value and a decrease in the utilization of adrenaline and atropine after cementation.

  3. State Waste Discharge Permit application, 183-N Backwash Discharge Pond

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect groundwater would be subject to permitting under the structure of Chapter 173--216 (or 173--218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Department of Energy, Richland Operations Office entered into Consent Order No. DE91NM-177, (Ecology and DOE-RL 1991). The Consent Order No. DE91NM-177 requires a series of permitting activities for liquid effluent discharges. Liquid effluents on the Hanford Site have been classified as Phase I, Phase II, and Miscellaneous Streams. The Consent Order No. DE91NM-177 establishes milestones for State Waste Discharge Permit application submittals for all Phase I and Phase II streams, as well as the following 11 Miscellaneous Streams as identified in Table 4 of the Consent Order No. DE91NM-177.

  4. Design of a Multi-Tube Pd-Membrane Module for Tritium Recovery from He in DEMO

    Directory of Open Access Journals (Sweden)

    Marco Incelli

    2016-10-01

    Full Text Available Dense self-supported Pd-alloy membranes are used to selectively separate hydrogen and hydrogen isotopes. In particular, deuterium (D and tritium (T are currently identified as the main elements for the sustainability of the nuclear fusion reaction aimed at carbon free power generation. In the fusion nuclear reactors, a breeding blanket produces the tritium that is extracted and purified before being sent to the plasma chamber in order to sustain the fusion reaction. In this work, the application of Pd-alloy membranes has been tested for recovering tritium from a solid breeding blanket through a helium purge stream. Several simulations have been performed in order to optimize the design of a Pd-Ag multi-tube module in terms of geometry, operating parameters, and membrane module configuration (series vs. parallel. The results demonstrate that a pre-concentration stage before the Pd-membrane unit is mandatory because of the very low tritium concentration in the He which leaves the breeding blanket of the fusion reactor. The most suitable operating conditions could be reached by: (i increasing the hydrogen partial pressure in the lumen side and (ii decreasing the shell pressure. The preliminary design of a membrane unit has been carried out for the case of the DEMO fusion reactor: the optimized membrane module consists of an array of 182 Pd-Ag tubes of 500 mm length, 10 mm diameter, and 0.100 mm wall thickness (total active area of 2.85 m2.

  5. On Degenerate Partial Differential Equations

    OpenAIRE

    Chen, Gui-Qiang G.

    2010-01-01

    Some of recent developments, including recent results, ideas, techniques, and approaches, in the study of degenerate partial differential equations are surveyed and analyzed. Several examples of nonlinear degenerate, even mixed, partial differential equations, are presented, which arise naturally in some longstanding, fundamental problems in fluid mechanics and differential geometry. The solution to these fundamental problems greatly requires a deep understanding of nonlinear degenerate parti...

  6. [Acrylic resin removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of

  7. Partial Epilepsy with Auditory Features

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2004-07-01

    Full Text Available The clinical characteristics of 53 sporadic (S cases of idiopathic partial epilepsy with auditory features (IPEAF were analyzed and compared to previously reported familial (F cases of autosomal dominant partial epilepsy with auditory features (ADPEAF in a study at the University of Bologna, Italy.

  8. Current-Induced Membrane Discharge

    DEFF Research Database (Denmark)

    Andersen, Mathias Bækbo; van Soestbergen, M.; Mani, A.

    2012-01-01

    . Salt depletion leads to a large electric field resulting in a local pH shift within the membrane with the effect that the membrane discharges and loses its ion selectivity. Since salt co-ions, H+ ions, and OH- ions contribute to OLC, CIMD interferes with electrodialysis (salt counterion removal...... neglects chemical effects and remains to be quantitatively tested. Here, we show that charge regulation and water self-ionization can lead to OLC by "current-induced membrane discharge'' (CIMD), even in the absence of fluid flow, in ion-exchange membranes much thicker than the local Debye screening length...

  9. Plasma Discharge in Toroidal System

    International Nuclear Information System (INIS)

    Usada, Widdi; Suryadi; Purwadi, Agus; Kasiyo

    1996-01-01

    A toroidal discharge apparatus has been made as an initial research in magnetic confinement system. This system consists of a capacitor, a RF source, an igniter system, a primary coil, a torus, and completed by Rogowski probe as a current detector. In this system, the discharge occurs when the minimum voltage is operated at 5 kV. The experiment result shows that the coupling factor is 0.35, it is proved that there is an equality between estimated and measurement results of the primary inductance i.e 8.5 μH

  10. Taming Instabilities in Plasma Discharges

    International Nuclear Information System (INIS)

    Klinger, T.; Krahnstover, N. O.; Mausbach, T.; Piel, A.

    2000-01-01

    Recent experimental work on taming instabilities in plasma discharges is discussed. Instead of suppressing instabilities, it is desired to achieve control over their dynamics, done by perturbing appropriately the current flow in the external circuit of the discharge. Different discrete and continuous feedback as well as open-loop control schemes are applied. Chaotic oscillations in plasma diodes are controlled using the OGY discrete feedback scheme. This is demonstrated both in experiment and computer simulation. Weakly developed ionization wave turbulence is tamed by continuous feedback control. Open-loop control of stochastic fluctuations - stochastic resonance - is demonstrated in a thermionic plasma diode. (author)

  11. Physico-chemical properties of Pd nanoparticles produced by Pulsed Laser Ablation in different organic solvents

    International Nuclear Information System (INIS)

    Cristoforetti, Gabriele; Pitzalis, Emanuela; Spiniello, Roberto; Ishak, Randa; Giammanco, Francesco; Muniz-Miranda, Maurizio; Caporali, Stefano

    2012-01-01

    Palladium nanoparticles are arousing an increasing interest because of their strong activity in heterogeneous catalysis in a wide range of reactions. Driven by the interest of producing Pd nanoparticles to be deposited for catalysis over hydrophobic supports, we investigated their synthesis via Pulsed Laser Ablation in Liquid in several organic solvents, as acetone, ethanol, 2-propanol, toluene, n-hexane. The colloids were produced by using a Nd:YAG ns laser and without the addition of surfactant agents. The morphology, composition, stability and oxidation state of the obtained nanoparticles were investigated by TEM-EDS analysis, UV-vis spectroscopy, X-ray Photoelectron Spectroscopy and micro-Raman spectroscopy. The results evidence that the nature of the solvent influences both the yield and the physico-chemical properties of the produced nanoparticles. While in acetone and alcohols spheroidal, non aggregated and stable particles are obtained, in case of toluene and n-hexane few unstable particles surrounded by a gel-like material are produced. Raman/XPS measurements suggest the presence of amorphous or graphitic carbon onto crystalline Pd nanoparticles, which could have hindered their growth and determined the observed smaller sizes if compared to nanoparticles produced in water. The stability of Pd colloids obtained in acetone and alcohols was attributed to adsorbed anions like enolates or alcoholates; non polar solvents like toluene and n-hexane, unable to give rise to adsorbed anionic species, cannot provide any stabilization to the palladium nanoparticles. XPS analyses also evidenced a partial oxidation of particles surface, with a ratio Pd 2+ :Pd 0 of 1:2.5 and 1:4 in acetone and ethanol, respectively.

  12. Dynamics diffusion behaviors of Pd small clusters on a Pd(1 1 1) surface

    International Nuclear Information System (INIS)

    Liu, Fusheng; Hu, Wangyu; Deng, Huiqiu; He, Rensheng; Yang, Xiyuan; Lu, Kuilin; Deng, Lei; Luo, Wenhua

    2010-01-01

    Using molecular dynamics, nudged elastic band and modified analytic embedded atom methods, the self-diffusion dynamics properties of palladium atomic clusters up to seven atoms on the Pd (1 1 1) surface have been studied at temperatures ranging from 300 to 1000 K. The simulation time varies from 20 to 75 ns according to the cluster sizes and the temperature ranges. The heptamer and trimer are more stable than the other neighboring clusters. The diffusion coefficients of the clusters are derived from the mean square displacement of the cluster's mass-center, and the diffusion prefactors D 0 and activation energies E a are derived from the Arrhenius relation. The activation energy of the clusters increases with the increasing atom number in the clusters, especially for Pd 6 to Pd 7 . The analysis of trajectories shows the noncompact clusters diffuse by the local diffusion mechanism but the compact clusters diffuse mainly by the whole gliding mechanism, and some static energy barriers of the diffusion modes are calculated. From Pd 2 to Pd 6 , the prefactors are in the range of the standard value 10 −3  cm 2  s −1 , and the prefactor of Pd 7 cluster is 2 orders of magnitude greater than that of the single Pd adatom because of a large number of nonequivalent diffusion processes. The heptamer can be the nucleus in the room temperature range according to nucleation theory

  13. Partial twisting for scalar mesons

    International Nuclear Information System (INIS)

    Agadjanov, Dimitri; Meißner, Ulf-G.; Rusetsky, Akaki

    2014-01-01

    The possibility of imposing partially twisted boundary conditions is investigated for the scalar sector of lattice QCD. According to the commonly shared belief, the presence of quark-antiquark annihilation diagrams in the intermediate state generally hinders the use of the partial twisting. Using effective field theory techniques in a finite volume, and studying the scalar sector of QCD with total isospin I=1, we however demonstrate that partial twisting can still be performed, despite the fact that annihilation diagrams are present. The reason for this are delicate cancellations, which emerge due to the graded symmetry in partially quenched QCD with valence, sea and ghost quarks. The modified Lüscher equation in case of partial twisting is given

  14. Lactoferricin B reverses cisplatin resistance in head and neck squamous cell carcinoma cells through targeting PD-L1.

    Science.gov (United States)

    Zhang, Pei; Liu, Jinzhong; Li, Wenlu; Li, Shanshan; Han, Xinguang

    2018-05-15

    Head and neck squamous cell carcinoma (HNSCC) ranks among the top most common cancers with a poor prognosis. The mechanism of chemoresistance is still not well known. This study is to investigate the programmed death-ligand 1 (PD-L1) expression in HNSCC, and test the effect of lactoferricin B (LfcinB) on chemoresistance and its mechanism. We analyzed 510 HNSCC patients in TCGA database and investigated how CD274 expression was related to patient prognosis. PD-L1 was verified from HNSCC samples at local hospital with immunohistochemistry. PD-L1 expression in the acquired cisplatin-resistant HNSCC cells was examined by PCR and WB in order to test PD-L1-induced chemoresistance. LfcinB inoculation in cisplatin-resistant HNSCC cells and in the nude mice was introduced to test the effect of LfcinB on targeting cisplatin resistance and its mechanism. High CD274 mRNA (>125 FPKM) from TCGA database had a significantly reduced 5-year survival rate, and a lower 5-year survival rate in the chemotherapy and radiotherapy-treated patients (P < .05). PD-L1 overexpression was further supported from analysis of 40 HNSCC specimens. PD-L1 and IL-6 in the established cisplatin-resistant HNSCC cells were shown significantly higher (P < .05). IL-6 and PD-L1 expression were partially inhibited by the anti-IL-6/STAT3 antibody. LfcinB displayed a direct cytotoxic effect on cisplatin-resistant HNSCC cells and HNSCC xenografts of cisplatin-resistant cells in the nude mice displayed significant reduction in tumor volume after LfcinB injection (P < .05). Besides, the increase of IL-6 and PD-L1 in cisplatin-resistant HNSCC cells was abolished in vitro by LfcinB (P < .05). PD-L1 expression in HNSCC cells correlates with poor prognosis and chemoresistance, and LfcinB might provide therapeutic potential in HNSCC patients through modulating IL-6 and PD-L1. © 2018 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  15. Magnetic characteristics of CoPd and FePd antidot arrays on nanoperforated Al_2O_3 templates

    International Nuclear Information System (INIS)

    Maximenko, A.; Fedotova, J.; Marszałek, M.; Zarzycki, A.; Zabila, Y.

    2016-01-01

    Hard magnetic antidot arrays show promising results in context of designing of percolated perpendicular media. In this work the technology of magnetic FePd and CoPd antidot arrays fabrication is presented and correlation between surface morphology, structure and magnetic properties is discussed. CoPd and FePd antidot arrays were fabricated by deposition of Co/Pd and Fe/Pd multilayers (MLs) on porous anodic aluminum oxide templates with bowl-shape cell structure with inclined intercellular regions. FePd ordered L1_0 structure was obtained by successive vacuum annealing at elevated temperatures (530 °C) and confirmed by XRD analysis. Systematic analysis of magnetization curves evidenced perpendicular magnetic anisotropy of CoPd antidot arrays, while FePd antidot arrays revealed isotropic magnetic anisotropy with increased out-of-plane magnetic contribution. MFM images of antidots showed more complicated contrast, with alternating magnetic dots oriented parallel and antiparallel to tip magnetization moment. - Highlights: • CoPd and FePd antidots were fabricated on porous anodic aluminum oxide templates. • CoPd antidot arrays have perpendicular magnetic anisotropy. • FePd antidot arrays revealed isotropic magnetic behavior. • The complex morphology of nanoporous template resulted in a complex magnetic domains image.

  16. Atomic displacements due to interstitial hydrogen in Cu and Pd

    Indian Academy of Sciences (India)

    2015-11-27

    Nov 27, 2015 ... Atomic displacements; density functional theory; Kanzaki method. ... pseudopotentials for H, Cu and Pd are generated self-consistently. ... Both Cu and Pd lattices show lattice expansion due to the presence of hydrogen and ...

  17. Nitrite reduction mechanism on a Pd surface.

    Science.gov (United States)

    Shin, Hyeyoung; Jung, Sungyoon; Bae, Sungjun; Lee, Woojin; Kim, Hyungjun

    2014-11-04

    Nitrate (NO3-) is one of the most harmful contaminants in the groundwater, and it causes various health problems. Bimetallic catalysts, usually palladium (Pd) coupled with secondary metallic catalyst, are found to properly treat nitrate-containing wastewaters; however, the selectivity toward N2 production over ammonia (NH3) production still requires further improvement. Because the N2 selectivity is determined at the nitrite (NO2-) reduction step on the Pd surface, which occurs after NO3- is decomposed into NO2- on the secondary metallic catalyst, we here performed density functional theory (DFT) calculations and experiments to investigate the NO2- reduction pathway on the Pd surface activated by hydrogen. Based on extensive DFT calculations on the relative energetics among ∼100 possible intermediates, we found that NO2- is easily reduced to NO* on the Pd surface, followed by either sequential hydrogenation steps to yield NH3 or a decomposition step to N* and O* (an adsorbate on Pd is denoted using an asterisk). Based on the calculated high migration barrier of N*, we further discussed that the direct combination of two N* to yield N2 is kinetically less favorable than the combination of a highly mobile H* with N* to yield NH3. Instead, the reduction of NO2- in the vicinity of the N* can yield N2O* that can be preferentially transformed into N2 via diverse reaction pathways. Our DFT results suggest that enhancing the likelihood of N* encountering NO2- in the solution phase before combination with surface H* is important for maximizing the N2 selectivity. This is further supported by our experiments on NO2- reduction by Pd/TiO2, showing that both a decreased H2 flow rate and an increased NO2- concentration increased the N2 selectivity (78.6-93.6% and 57.8-90.9%, respectively).

  18. Superdeformation in /sup 104,105/Pd

    International Nuclear Information System (INIS)

    Macchiavelli, A.O.; Burde, J.; Diamond, R.M.; Beausang, C.W.; Deleplanque, M.A.; McDonald, R.J.; Stephens, F.S.; Draper, J.E.

    1988-01-01

    In the present Rapid Communication, we report the discovery of a rotational band in /sup 105/Pd and possibly one in /sup 104/Pd that can be interpreted as arising from superdeformed shapes. The moments of inertia, J/sup (1)/ and J/sup (2)/, of these bands are similar to those measured in the Ce--Nd region, once the A/sup 5/3/ mass dependence is removed. This implies a deformation ε∼0.35--0.4. If so, this is the third mass region where superdeformed bands have been found at high spins

  19. Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients

    Directory of Open Access Journals (Sweden)

    Pramita Suwal

    2017-03-01

    Full Text Available Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy class I and II arches with or without modification areas were selected for the study. Group-A was treated with cast partial denture and Group-B with acrylic partial denture. Data collected during follow-up visit of 3 months, 6 months, and 1 year by evaluating retention, stability, masticatory efficiency, comfort, periodontal health of abutment. Results: Chi-square test was applied to find out differences between the groups at 95% confidence interval where p = 0.05. One year comparison shows that cast partial denture maintained retention and stability better than acrylic partial denture (p< 0.05. The masticatory efficiency was significantly compromising from 3rd month to 1 year in all acrylic partial denture groups (p< 0.05. The comfort of patient with cast partial denture was maintained better during the observation period (p< 0.05. Periodontal health of abutment was gradually deteriorated in all acrylic denture group (p

  20. Spheres of discharge of springs

    Science.gov (United States)

    Springer, Abraham E.; Stevens, Lawrence E.

    2009-02-01

    Although springs have been recognized as important, rare, and globally threatened ecosystems, there is as yet no consistent and comprehensive classification system or common lexicon for springs. In this paper, 12 spheres of discharge of springs are defined, sketched, displayed with photographs, and described relative to their hydrogeology of occurrence, and the microhabitats and ecosystems they support. A few of the spheres of discharge have been previously recognized and used by hydrogeologists for over 80 years, but others have only recently been defined geomorphologically. A comparison of these spheres of discharge to classification systems for wetlands, groundwater dependent ecosystems, karst hydrogeology, running waters, and other systems is provided. With a common lexicon for springs, hydrogeologists can provide more consistent guidance for springs ecosystem conservation, management, and restoration. As additional comprehensive inventories of the physical, biological, and cultural characteristics are conducted and analyzed, it will eventually be possible to associate spheres of discharge with discrete vegetation and aquatic invertebrate assemblages, and better understand the habitat requirements of rare or unique springs species. Given the elevated productivity and biodiversity of springs, and their highly threatened status, identification of geomorphic similarities among spring types is essential for conservation of these important ecosystems.

  1. Problems with textile wastewater discharge

    International Nuclear Information System (INIS)

    Rantala, Pentti

    1987-01-01

    The general character of textile industry wastewaters is briefly discussed. General guidelines and practice in Finland when discharging textile industry wastewaters to municipal sewer systems is described. A survey revealed that most municipalities experience some problems due to textile industry wastewaters. Pretreatment is not always practiced and in some cases pretreatment is not operated efficiently. (author)

  2. Discharge measurements at gaging stations

    Science.gov (United States)

    Turnipseed, D. Phil; Sauer, Vernon B.

    2010-01-01

    The techniques and standards for making discharge measurements at streamflow gaging stations are described in this publication. The vertical axis rotating-element current meter, principally the Price current meter, has been traditionally used for most measurements of discharge; however, advancements in acoustic technology have led to important developments in the use of acoustic Doppler current profilers, acoustic Doppler velocimeters, and other emerging technologies for the measurement of discharge. These new instruments, based on acoustic Doppler theory, have the advantage of no moving parts, and in the case of the acoustic Doppler current profiler, quickly and easily provide three-dimensional stream-velocity profile data through much of the vertical water column. For much of the discussion of acoustic Doppler current profiler moving-boat methodology, the reader is referred to U.S. Geological Survey Techniques and Methods 3-A22 (Mueller and Wagner, 2009). Personal digital assistants (PDAs), electronic field notebooks, and other personal computers provide fast and efficient data-collection methods that are more error-free than traditional hand methods. The use of portable weirs and flumes, floats, volumetric tanks, indirect methods, and tracers in measuring discharge are briefly described.

  3. Ions mobilities in corona discharge

    International Nuclear Information System (INIS)

    Bakhtaev, Sh. A.; Bochkareva, G. V.; Sydykova, G. K.

    2000-01-01

    Ion mobility in unipolar corona at small inter-electron distances (up to 0.01 m) when as coroning element serves micro-wire is consider. Experimental data of ion mobility in corona discharge external zone in atmospheric air are obtained and its comparative analysis with known data is worked out. (author)

  4. Air corona discharge chemical kinetics

    International Nuclear Information System (INIS)

    Kline, L.E.; Kanter, I.E.

    1984-01-01

    We have theoretically studied the initial chemical processing steps which occur in pulseless, negative, dc corona discharges in flowing air. A rate equation model is used because these discharges consist of a very small ionization zone near the pin with most of the pin-plane gap filled by a drift zone where both the electric field and the electron density are relatively uniform. The primary activated species are N 2 (A),O and O 2 (a 1 Δ). The predicted activated species density due to one discharge is 100 ppm per ms . mA cm 2 assuming E/n=60 Td. In pure, dry air the final product due to these activated species is primarily O 3 . The NO /sub x/ production is about 0.5 ppm per mA. In moist air there is an additional production of about 1.5 ppm per mA of HO /sub x/ species. The predicted ozone formation reactions will be ''intercepted'' when impurities are present in the air. Impurities present at densities below about 0.1% will react primarily with the activated species rather than with electrons. Hence the predicted activated species density provides an estimate of the potential chemical processing performance of the discharge

  5. Electronic Discharge Letter Mobile App

    NARCIS (Netherlands)

    Lezcano, Leonardo; Triana, Michel; Ternier, Stefaan; Hartkopf, Kathleen; Stieger, Lina; Schroeder, Hanna; Sopka, Sasa; Drachsler, Hendrik; Maher, Bridget; Henn, Patrick; Orrego, Carola; Specht, Marcus

    2014-01-01

    The electronic discharge letter mobile app takes advantage of Near Field Communication (NFC) within the PATIENT project and a related post-doc study. NFC enabled phones to read passive RFID tags, but can also use this short-range wireless technology to exchange (small) messages. NFC in that sense

  6. Discharge cleaning of carbon deposits

    International Nuclear Information System (INIS)

    Mozetic, M.; Vesel, A.; Drenik, A.

    2006-01-01

    Experimental results of discharge cleaning of carbon deposits are presented. Deposits were prepared by creating plasma in pure methane. The methane was cracked in RF discharge at the output power of 250 W. The resultant radicals were bonded to the wall of discharge vessel forming a thin film of hydrogenated black carbon with the thickness of about 200nm. The film was then cleaned in situ by oxygen plasma with the density of about 1x10 16 m -3 , electron temperature of 5 eV, neutral gas kinetic temperature of about 100 0 C and neutral atom density of 6x10 21 m -3 . The treatment time was 30 minutes. The efficiency of plasma cleaning was monitored by optical emission spectroscopy. As long as the wall was contaminated with carbon deposit, substantial emission of the CO molecules was detected. As the cleaning was in progress, the CO emission was decreasing and vanished after 30 minutes when the discharge vessel became free of any carbon. The results are explained by interaction of plasma radicals with carbon deposits. (author)

  7. An experimental detrending approach to attributing change of pan evaporation in comparison with the traditional partial differential method

    Science.gov (United States)

    Wang, Tingting; Sun, Fubao; Xia, Jun; Liu, Wenbin; Sang, Yanfang

    2017-04-01

    In predicting how droughts and hydrological cycles would change in a warming climate, change of atmospheric evaporative demand measured by pan evaporation (Epan) is one crucial element to be understood. Over the last decade, the derived partial differential (PD) form of the PenPan equation is a prevailing attribution approach to attributing changes to Epan worldwide. However, the independency among climatic variables required by the PD approach cannot be met using long term observations. Here we designed a series of numerical experiments to attribute changes of Epan over China by detrending each climatic variable, i.e., an experimental detrending approach, to address the inter-correlation among climate variables, and made comparison with the traditional PD method. The results show that the detrending approach is superior not only to a complicate system with multi-variables and mixing algorithm like aerodynamic component (Ep,A) and Epan, but also to a simple case like radiative component (Ep,R), when compared with traditional PD method. The major reason for this is the strong and significant inter-correlation of input meteorological forcing. Very similar and fine attributing results have been achieved based on detrending approach and PD method after eliminating the inter-correlation of input through a randomize approach. The contribution of Rh and Ta in net radiation and thus Ep,R, which has been overlooked based on the PD method but successfully detected by detrending approach, provides some explanation to the comparing results. We adopted the control run from the detrending approach and applied it to made adjustment of PD method. Much improvement has been made and thus proven this adjustment an effective way in attributing changes to Epan. Hence, the detrending approach and the adjusted PD method are well recommended in attributing changes in hydrological models to better understand and predict water and energy cycle.

  8. Sputtered Pd as hydrogen storage for a chip-integrated microenergy system.

    Science.gov (United States)

    Slavcheva, E; Ganske, G; Schnakenberg, U

    2014-01-01

    The work presents a research on preparation and physical and electrochemical characterisation of dc magnetron sputtered Pd films envisaged for application as hydrogen storage in a chip-integrated hydrogen microenergy system. The influence of the changes in the sputtering pressure on the surface structure, morphology, and roughness was analysed by X-ray diffraction (XRD), scanning electron microscopy (SEM), and atomic force microscopy (AMF). The electrochemical activity towards hydrogen adsorption/desorption and formation of PdH were investigated in 0.5 M H2SO4 using the methods of cyclic voltammetry and galvanostatic polarisation. The changes in the electrical properties of the films as a function of the sputtering pressure and the level of hydrogenation were evaluated before and immediately after the electrochemical charging tests, using a four-probe technique. The research resulted in establishment of optimal sputter regime, ensuring fully reproducible Pd layers with highly developed surface, moderate porosity, and mechanical stability. Selected samples were integrated as hydrogen storage in a newly developed unitized microenergy system and tested in charging (water electrolysis) and discharging (fuel cell) operative mode at ambient conditions demonstrating a stable recycling performance.

  9. Redox reactions with empirical potentials: atomistic battery discharge simulations.

    Science.gov (United States)

    Dapp, Wolf B; Müser, Martin H

    2013-08-14

    Batteries are pivotal components in overcoming some of today's greatest technological challenges. Yet to date there is no self-consistent atomistic description of a complete battery. We take first steps toward modeling of a battery as a whole microscopically. Our focus lies on phenomena occurring at the electrode-electrolyte interface which are not easily studied with other methods. We use the redox split-charge equilibration (redoxSQE) method that assigns a discrete ionization state to each atom. Along with exchanging partial charges across bonds, atoms can swap integer charges. With redoxSQE we study the discharge behavior of a nano-battery, and demonstrate that this reproduces the generic properties of a macroscopic battery qualitatively. Examples are the dependence of the battery's capacity on temperature and discharge rate, as well as performance degradation upon recharge.

  10. New discharge tube with virtual cathode

    International Nuclear Information System (INIS)

    Seidelmann, L.; Aubrecht, L.

    2003-01-01

    Till this time known methods of the excitation of the discharge between electrodes are using either secondary or thermo emission of electrons by the cathode. Usually we speak about the self-maintained discharge. Lifetime of the cathode, that is shortened by the emission, limits in principle, the lifetime of the whole discharge tube. The discharge can, according to the present state of the art, be induced also by the inductive way. Arrangement for excitation of such discharge is rather expensive. The construction of the inductive excited discharge tube is considerably influenced by the necessity of the limitation of the losses in excitation magnetic circuits. Especially length of the discharge and pressure of the working gas are limited by the economic standpoints. Function of the discharge is always connected with unwanted electromagnetic radiation, whose restraint is expensive and represents limiting factor for arrangement of the discharge tube (Authors)

  11. Expression of PD-1 and PD-L1 in poorly differentiated neuroendocrine carcinomas of the digestive system: a potential target for anti-PD-1/PD-L1 therapy.

    Science.gov (United States)

    Roberts, Jordan A; Gonzalez, Raul S; Das, Satya; Berlin, Jordan; Shi, Chanjuan

    2017-12-01

    Poorly differentiated neuroendocrine carcinoma of the digestive system has a dismal prognosis with limited treatment options. This study aimed to investigate expression of the PD-1/PD-L1 pathway in these tumors. Thirty-seven patients with a poorly differentiated neuroendocrine carcinoma of the digestive system were identified. Their electronic medical records, pathology reports, and pathology slides were reviewed for demographics, clinical history, and pathologic features. Tumor sections were immunohistochemically labeled for PD-1 and PD-L1, and expression of PD-1 and PD-L1 on tumor and tumor-associated immune cells was analyzed and compared between small cell and large cell neuroendocrine carcinomas. The mean age of patients was 61 years old with 18 men and 19 women. The colorectum (n=20) was the most common primary site; other primary sites included the pancreaticobiliary system, esophagus, stomach, duodenum, and ampulla. Expression of PD-1 was detected on tumor cells (n=6, 16%) as well as on tumor-associated immune cells (n=23, 63%). The 6 cases with PD-1 expression on tumor cells also had the expression on immune cells. Expression of PD-L1 was visualized on tumor cells in 5 cases (14%) and on tumor-associated immune cells in 10 cases (27%). There was no difference in PD-1 and PD-L1 expression between small cell and large cell neuroendocrine carcinomas. In conclusion, PD-1/PD-L1 expression is a frequent occurrence in poorly differentiated neuroendocrine carcinomas of the digestive system. Checkpoint blockade targeting the PD-1/PD-L1 pathway may have a potential role in treating patients with this disease. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. PD-1 Checkpoint Inhibitor Associated Autoimmune Encephalitis

    Directory of Open Access Journals (Sweden)

    Stephanie Schneider

    2017-05-01

    Full Text Available Objective: To report first-hand narrative experience of autoimmune encephalitis and to briefly review currently available evidence of autoimmune encephalitis in cancer patients treated with immune checkpoint inhibitors. Setting: A case study is presented on the management of a patient who developed autoimmune encephalitis during nivolumab monotherapy occurring after 28 weeks on anti-PD-1 monotherapy (nivolumab 3 mg/kg every 2 weeks for non-small cell lung cancer. Results: No substantial improvement was observed by antiepileptic treatment. After administration of 80 mg methylprednisolone, neurologic symptoms disappeared within 24 h and the patient fully recovered. Conclusions: Immune checkpoint inhibitor treatment can lead to autoimmune encephalitis. Clinical trial data indicate a frequency of autoimmune encephalitis of ≥0.1 to <1% with a higher probability during combined or sequential anti-CTLA-4/anti-PD-1 therapy than during anti-PD-1 or anti-PD-L1 monotherapy. Further collection of evidence and translational research is warranted.

  13. Investigation of antimagnetic rotation in 100Pd

    International Nuclear Information System (INIS)

    Zhu, S.; Garg, U.; Afanasjev, A. V.; Frauendorf, S.; Kharraja, B.; Ghugre, S. S.; Chintalapudi, S. N.; Janssens, R. V. F.; Carpenter, M. P.; Kondev, F. G.

    2001-01-01

    High spin states have been studied in the nucleus 100 Pd with the aim of investigating the novel phenomenon of ''antimagnetic rotation.'' A cascade of four ''rotational-band-like'' transitions is proposed as corresponding to antimagnetic rotation, based on the observed spectroscopic properties and a comparison with calculations in the configuration-dependent cranked Nilsson-Strutinsky formalism

  14. Ferromagnetism of Pd-Fe (abstract)

    Science.gov (United States)

    Griffith, G.; Carnegie, D. W., Jr.; Claus, H.

    1984-03-01

    We present new low field ac susceptibility measurements on Pd1-xFex alloys (0.002≤X<0.01). The Curie temperature TC, determined from these measurements, are significantly lower than those previously obtained in higher magnetic fields [G. J. Nieuwenhuys, Adv. Phys. 24, 515 (1975)]. We also found that for a given sample, TC depends very sensitively on its heat treatment. As an example, for an alloy with 0.4 at. % Fe, TC can be varied between 4 and 10 K. In other alloys, like PdNi or RhNi similar changes in TC are due to changes in the degree of atomic short-range order [S. Crane, D. W. Carnegie, Jr., and H. Claus, J. Appl. Phys. 53, 2179 (1982)]. However, for PdFe we show evidence that the changes in TC are due to absorption of small amounts of oxygen, the samples with the highest amount of oxygen having the highest TC. It thus seems that oxygen has the opposite effect from hydrogen on the exchange enhanced susceptibility of Pd [J. A. Mydosh, Phys. Rev. Lett. 33, 1562 (1974)].

  15. Partially massless fields during inflation

    Science.gov (United States)

    Baumann, Daniel; Goon, Garrett; Lee, Hayden; Pimentel, Guilherme L.

    2018-04-01

    The representation theory of de Sitter space allows for a category of partially massless particles which have no flat space analog, but could have existed during inflation. We study the couplings of these exotic particles to inflationary perturbations and determine the resulting signatures in cosmological correlators. When inflationary perturbations interact through the exchange of these fields, their correlation functions inherit scalings that cannot be mimicked by extra massive fields. We discuss in detail the squeezed limit of the tensor-scalar-scalar bispectrum, and show that certain partially massless fields can violate the tensor consistency relation of single-field inflation. We also consider the collapsed limit of the scalar trispectrum, and find that the exchange of partially massless fields enhances its magnitude, while giving no contribution to the scalar bispectrum. These characteristic signatures provide clean detection channels for partially massless fields during inflation.

  16. Microbially supported synthesis of catalytically active bimetallic Pd-Au nanoparticles

    DEFF Research Database (Denmark)

    Hosseinkhani, Baharak; Søbjerg, Lina Sveidal; Rotaru, Amelia-Elena

    2012-01-01

    Transformation (FFT) analyses confirmed that the nanoparticles indeed were bimetallic. The bimetallic nanoparticles did not have a core-shell structure, but were superior to monometallic particles at reducing p-nitrophenol to p-aminophenol. Hence, formation of microbially supported nanoparticles may be a cheap......(II) to the bio-supported particles resulted in increased particle size. UV-Vis spectrophotometry and HR-TEM analyses indicated that the previously monometallic nanoparticles had become fully or partially covered by Au(0) or Pd(0), respectively. Furthermore, Energy Dispersive Spectrometry (EDS) and Fast Fourier...

  17. Metadislocation reactions and metadislocation networks in the complex metallic alloy ξ'-Al-Pd-Mn

    International Nuclear Information System (INIS)

    Heggen, Marc; Feuerbacher, Michael

    2005-01-01

    Metadislocations are novel structural defects firstly observed in the complex metallic alloy ξ'-Al-Pd-Mn. We present a transmission electron microscopy study on metadislocation reactions and networks. It is shown that metadislocations can dissociate into partials, which leads to a decrease of the elastic line energy. Connected groups of metadislocations can assume large and complex network structures with large total Burgers vectors. However, the local elastic strain at the individual metadislocation cores as well as the fault-plane energies remain small. By this mechanism, effective large Burgers vectors, contributing massively to plastic strain, can be distributed over a large portion of the material

  18. Circulating precursor CCR7(lo)PD-1(hi) CXCR5⁺ CD4⁺ T cells indicate Tfh cell activity and promote antibody responses upon antigen reexposure.

    Science.gov (United States)

    He, Jing; Tsai, Louis M; Leong, Yew Ann; Hu, Xin; Ma, Cindy S; Chevalier, Nina; Sun, Xiaolin; Vandenberg, Kirsten; Rockman, Steve; Ding, Yan; Zhu, Lei; Wei, Wei; Wang, Changqi; Karnowski, Alexander; Belz, Gabrielle T; Ghali, Joanna R; Cook, Matthew C; Riminton, D Sean; Veillette, André; Schwartzberg, Pamela L; Mackay, Fabienne; Brink, Robert; Tangye, Stuart G; Vinuesa, Carola G; Mackay, Charles R; Li, Zhanguo; Yu, Di

    2013-10-17

    Follicular B helper T (Tfh) cells support high affinity and long-term antibody responses. Here we found that within circulating CXCR5⁺ CD4⁺ T cells in humans and mice, the CCR7(lo)PD-1(hi) subset has a partial Tfh effector phenotype, whereas CCR7(hi)PD-1(lo) cells have a resting phenotype. The circulating CCR7(lo)PD-1(hi) subset was indicative of active Tfh differentiation in lymphoid organs and correlated with clinical indices in autoimmune diseases. Thus the CCR7(lo)PD-1(hi) subset provides a biomarker to monitor protective antibody responses during infection or vaccination and pathogenic antibody responses in autoimmune diseases. Differentiation of both CCR7(hi)PD-1(lo) and CCR7(lo)PD-1(hi) subsets required ICOS and BCL6, but not SAP, suggesting that circulating CXCR5⁺ helper T cells are primarily generated before germinal centers. Upon antigen reencounter, CCR7(lo)PD-1(hi) CXCR5⁺ precursors rapidly differentiate into mature Tfh cells to promote antibody responses. Therefore, circulating CCR7(lo)PD-1(hi) CXCR5⁺ CD4⁺ T cells are generated during active Tfh differentiation and represent a new mechanism of immunological early memory. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Introduction to partial differential equations

    CERN Document Server

    Greenspan, Donald

    2000-01-01

    Designed for use in a one-semester course by seniors and beginning graduate students, this rigorous presentation explores practical methods of solving differential equations, plus the unifying theory underlying the mathematical superstructure. Topics include basic concepts, Fourier series, second-order partial differential equations, wave equation, potential equation, heat equation, approximate solution of partial differential equations, and more. Exercises appear at the ends of most chapters. 1961 edition.

  20. Feasibility of wear compensation in micro EDM milling based on discharge counting and discharge population characterization

    DEFF Research Database (Denmark)

    Bissacco, Giuliano; Hansen, Hans Nørgaard; Tristo, G.

    2011-01-01

    This paper investigates the applicability of real time wear compensation in micro EDM milling based on discharge counting and discharge population characterization. Experiments were performed involving discharge counting and tool electrode wear measurement in a wide range of process parameters...

  1. Methanol steam reforming over Pd/ZnO and Pd/CeO{sub 2} catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Ranganathan, Easwar S.; Bej, Shyamal K.; Thompson, Levi T. [University of Michigan, Department of Chemical Engineering, 3026 H.H. Dow Building, 2300 Hayward Avenue, Ann Arbor, MI 48109-2136 (United States)

    2005-08-10

    The goal of work described in this paper was to better understand the methanol steam reforming (MSR) activity and selectivity patterns of ZnO and CeO{sub 2} supported Pd catalysts. This reaction is being used to produce H{sub 2}-rich gas for a number of applications including hydrogen fuel cells. The Pd/ZnO catalysts had lower MSR rates but were more selective for the production of CO{sub 2} than the Pd/CeO{sub 2} catalysts. The CH{sub 3}OH conversion rates were proportional to the H{sub 2} chemisorption uptake suggesting that the rate determining step was catalyzed by Pd. The corresponding turnover frequencies averaged 0.8+/-0.3s{sup -1} and 0.4+/-0.2s{sup -1} at 230{sup o}C for the Pd/ZnO and Pd/CeO{sub 2} catalysts, respectively. The selectivities are explained based on the reaction pathways, and characteristics of the support. The key surface intermediate appeared to be a formate. The ZnO supported catalysts had a higher density of acidic sites and favored pathways where the intermediate was converted to CO{sub 2} while the CeO{sub 2} supported catalysts had a higher density of basic sites and favored the production of CO.

  2. Kinetics of monolayer graphene growth by segregation on Pd(111)

    Energy Technology Data Exchange (ETDEWEB)

    Mok, H. S.; Murata, Y.; Kodambaka, S., E-mail: kodambaka@ucla.edu [Department of Materials Science and Engineering, University of California Los Angeles, Los Angeles, California 90095 (United States); Ebnonnasir, A.; Ciobanu, C. V. [Department of Mechanical Engineering and Materials Science Program, Colorado School of Mines, Golden, Colorado 80401 (United States); Nie, S.; McCarty, K. F. [Sandia National Laboratories, Livermore, California 94550 (United States)

    2014-03-10

    Using in situ low-energy electron microscopy and density functional theory calculations, we follow the growth of monolayer graphene on Pd(111) via surface segregation of bulk-dissolved carbon. Upon lowering the substrate temperature, nucleation of graphene begins on graphene-free Pd surface and continues to occur during graphene growth. Measurements of graphene growth rates and Pd surface work functions establish that this continued nucleation is due to increasing C adatom concentration on the Pd surface with time. We attribute this anomalous phenomenon to a large barrier for attachment of C adatoms to graphene coupled with a strong binding of the non-graphitic C to the Pd surface.

  3. Kinetics of monolayer graphene growth by segregation on Pd(111)

    International Nuclear Information System (INIS)

    Mok, H. S.; Murata, Y.; Kodambaka, S.; Ebnonnasir, A.; Ciobanu, C. V.; Nie, S.; McCarty, K. F.

    2014-01-01

    Using in situ low-energy electron microscopy and density functional theory calculations, we follow the growth of monolayer graphene on Pd(111) via surface segregation of bulk-dissolved carbon. Upon lowering the substrate temperature, nucleation of graphene begins on graphene-free Pd surface and continues to occur during graphene growth. Measurements of graphene growth rates and Pd surface work functions establish that this continued nucleation is due to increasing C adatom concentration on the Pd surface with time. We attribute this anomalous phenomenon to a large barrier for attachment of C adatoms to graphene coupled with a strong binding of the non-graphitic C to the Pd surface

  4. [Acrylic resin removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Creugers, N H J

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of removable partial dentures, the acrylic resin removable partial denture has 3 favourable aspects: the economic aspect, its aesthetic quality and the ease with which it can be extended and adjusted. Disadvantages are an increased risk of caries developing, gingivitis, periodontal disease, denture stomatitis, alveolar bone reduction, tooth migration, triggering of the gag reflex and damage to the acrylic resin base. Present-day indications are ofa temporary or palliative nature or are motivated by economic factors. Special varieties of the acrylic resin removable partial denture are the spoon denture, the flexible denture fabricated of non-rigid acrylic resin, and the two-piece sectional denture. Furthermore, acrylic resin removable partial dentures can be supplied with clasps or reinforced by fibers or metal wires.

  5. Relativistic Electrons in Electric Discharges

    DEFF Research Database (Denmark)

    Cinar, Deniz

    at the time when also gigantic electric discharges were observed at 10-90 km altitude in the stratosphere and mesosphere, the so called “jets” and “sprites”, commonly referred to as “Transient Luminous Events” (TLEs). TGFs were _rst thought connected to TLEs, but later research has pointed to lightning......Thunderstorms generate bursts of X- and Gamma radiation. When observed from spacecraft, the bursts are referred to as “Terrestrial Gamma-ray Flashes” (TGFs). They are bremsstrahlung from energetic electrons accelerated in thunderstorm electric _elds. The TGFs were _rst observed in the 90ties...... discharges as the source. The “Atmosphere-Space Interactions Monitor” (ASIM) for the International Space Station in 2016, led by DTU Space, and the French microsatellite TARANIS, also with launch in 2016, will identify with certainty the source of TGFs. In preparation for the missions, the Ph.D. project has...

  6. Runaway electrons in toroidal discharges

    International Nuclear Information System (INIS)

    Knoepfel, H.

    1979-01-01

    Experimental and theoretical studies of runaway electrons in toroidal devices are reviewed here, with particular reference to tokamaks. The complex phenomenology of runaway effects, which have been the subject of research for the past twenty years, is organized within the framework of a number of physical models. The mechanisms and rates for runaway production are discussed first, followed by sections on runaway-driven kinetic relaxation processes and runaway orbit confinement. Next, the equilibrium and stability of runaway-dominated discharges are reviewed. Models for runaway production at early times in the discharge and the scaling of runaway phenomena to larger devices are also discussed. Finally, detection techniques and possible applications of runaways are mentioned. (author)

  7. Energy discharge heater power supply

    International Nuclear Information System (INIS)

    Jaskierny, W.

    1992-11-01

    The heater power supply is intended to supply capacitively stored,energy to embedded heater strips in cryo magnets. The amount of energy can be controlled by setting different charge different capacitor values. Two chassis' can be operated in series or interlocks are provided. The charge voltage, number of capacitors pulse can be monitored. There and dual channel has two discharge supplies in one chassis. This report reviews the characteristics of this power supply further

  8. Electrostatic probes in luminescent discharges

    International Nuclear Information System (INIS)

    Cunha Raposo, C. da.

    1980-01-01

    A system to produce luminescent type plasma by continuos discharge and ionization by high frequency was constructed. The ionization was done in the air and in the argon under pressures from 3 to 10 mmHg. The parameters of a non magnetized collisional plasma and the parameters of a magnetized plasma such as, density, eletron temperature and potential, using a Langmuir probe with plane geometry, were determined. (M.C.K.) [pt

  9. Self-assembly of bimetallic AuxPd1-x alloy nanoparticles via dewetting of bilayers through the systematic control of temperature, thickness, composition and stacking sequence

    Science.gov (United States)

    Kunwar, Sundar; Pandey, Puran; Sui, Mao; Bastola, Sushil; Lee, Jihoon

    2018-03-01

    Bimetallic alloy nanoparticles (NPs) are attractive materials for various applications with their morphology and elemental composition dependent optical, electronic, magnetic and catalytic properties. This work demonstrates the evolution of AuxPd1-x alloy nanostructures by the solid-state dewetting of sequentially deposited bilayers of Au and Pd on sapphire (0001). Various shape, size and configuration of AuxPd1‑x alloy NPs are fabricated by the systematic control of annealing temperature, deposition thickness, composition as well as stacking sequence. The evolution of alloy nanostructures is attributed to the surface diffusion, interface diffusion between bilayers, surface and interface energy minimization, Volmer-Weber growth model and equilibrium configuration. Depending upon the temperature, the surface morphologies evolve with the formation of pits, grains and voids and gradually develop into isolated semi-spherical alloy NPs by the expansion of voids and agglomeration of Au and Pd adatoms. On the other hand, small isolated to enlarged elongated and over-grown layer-like alloy nanostructures are fabricated due to the coalescence, partial diffusion and inter-diffusion with the increased bilayer thickness. In addition, the composition and stacking sequence of bilayers remarkably affect the final geometry of AuxPd1‑x nanostructures due to the variation in the dewetting process. The optical analysis based on the UV–vis-NIR reflectance spectra reveals the surface morphology dependent plasmonic resonance, scattering, reflection and absorption properties of AuxPd1‑x alloy nanostructures.

  10. Reduction of deviation angle during occlusion therapy: in partially accommodative esotropia with moderate amblyopia.

    Science.gov (United States)

    Chun, Bo Young; Kwon, Soon Jae; Chae, Sun Hwa; Kwon, Jung Yoon

    2007-09-01

    To evaluate changes in ocular alignment in partially accommodative esotropic children age ranged from 3 to 8 years during occlusion therapy for amblyopia. Angle measurements of twenty-two partially accommodative esotropic patients with moderate amblyopia were evaluated before and at 2 years after occlusion therapy. Mean deviation angle with glasses at the start of occlusion treatment was 19.45+/-5.97 PD and decreased to 12.14+/-12.96 PD at 2 years after occlusion therapy (pocclusion therapy, 9 (41%) cases were indications of surgery for residual deviation but if we had planned surgery before occlusion treatment, 18 (82%) of patients would have had surgery. There was a statistical relationship between increase of visual acuity ratio and decrease of deviation angle (r=-0.479, p=0.024). There was a significant reduction of deviation angle of partially accommodative esotropic patients at 2 years after occlusion therapy. Our results suggest that occlusion therapy has an influence on ocular alignment in partially accommodative esotropic patients with amblyopia.

  11. Internal Electrostatic Discharge Monitor - IESDM

    Science.gov (United States)

    Kim, Wousik; Goebel, Dan M.; Jun, Insoo; Garrett, Henry B.

    2011-01-01

    A document discusses an innovation designed to effectively monitor dielectric charging in spacecraft components to measure the potential for discharge in order to prevent damage from internal electrostatic discharge (IESD). High-energy electrons penetrate the structural materials and shielding of a spacecraft and then stop inside dielectrics and keep accumulating. Those deposited charges generate an electric field. If the electric field becomes higher than the breakdown threshold (approx. =2 x 10(exp 5) V/cm), discharge occurs. This monitor measures potentials as a function of dielectric depth. Differentiation of potential with respect to the depth yields electric field. Direct measurement of the depth profile of the potential in a dielectric makes real-time electronic field evaluation possible without simulations. The IESDM has been designed to emulate a multi-layer circuit board, to insert very thin metallic layers between the dielectric layers. The conductors serve as diagnostic monitoring locations to measure the deposited electron-charge and the charge dynamics. Measurement of the time-dependent potential of the metal layers provides information on the amount of charge deposited in the dielectrics and the movement of that charge with time (dynamics).

  12. A theoretical derivation of the transients related to partial discharges in ellipsoidal voids

    DEFF Research Database (Denmark)

    Crichton, George C; Karlsson, A.; Pedersen, Aage

    1988-01-01

    be drawn about the effects of the gas within the void as well as the size, shape, and location of voids. The method is illustrated by applying it to a spheroidal void in a simple disk-type gas-insulated-substation (GIS) spacer. It is found that the nonattaching gas generates an induced charge...

  13. PD-1 Blockade in Advanced Melanoma in Patients with Hepatitis C and/or HIV

    Directory of Open Access Journals (Sweden)

    Diwakar Davar

    2015-01-01

    Full Text Available On the basis of remarkable antitumor activity, programmed death receptor-1 (PD-1 inhibitors pembrolizumab and nivolumab were approved for the treatment of advanced melanoma in the second-line setting following progression on either CTLA-4 inhibitor ipilimumab or BRAF/MEK inhibitors (for BRAF mutated melanoma. Given hypothesized risk of triggering exacerbations of autoimmune diseases and/or chronic viral infections, clinical trials (including regulatory studies evaluating checkpoint blocking antibodies PD-1 and CTLA-4 have excluded patients with autoimmune diseases, chronic hepatitis B/C virus (HBV/HCV, and/or human immunodeficiency virus (HIV infections. Herein, we describe two patients with advanced melanoma and concomitant HCV/HIV infections treated with PD-1 inhibitor pembrolizumab. Patient 2 with HIV/HCV coinfection progressed after 2 doses of pembrolizumab. Patient 1 who had HCV alone was treated with pembrolizumab with initial partial response. HCV viral load remained stable after 9 cycles of pembrolizumab following which 12-week course of HCV-directed therapy was commenced, resulting in prompt reduction of HCV viral load below detectable levels. Response is ongoing and HCV viral load remains undetectable. In both patients, no significant toxicities were observed when pembrolizumab was initiated. We argue for the further investigation of checkpoint inhibition in cancer patients with underlying chronic viral infections in the context of carefully designed clinical trials.

  14. Clinical evaluation of removable partial dentures on the periodontal health of abutment teeth: a retrospective study.

    Science.gov (United States)

    Dula, Linda J; Ahmedi, Enis F; Lila-Krasniqi, Zana D; Shala, Kujtim Sh

    2015-01-01

    The aim of this retrospective study was to evaluate the effect of removable partial dentures in periodontal abutment teeth in relation to the type of denture support and design of RPD in a five-year worn period. Methods : A total of 64 patients with removable partial dentures (RPDs), participated in this study. It were examined ninety-one RPDs. There were seventy-five RPDs with clasp-retained and sixteenth were RPDs with attachments. There were 28 females and 36 males, aged between 40-64 years, 41 maxillary and 50 mandible RPDs. For each subjects the following data were collected: denture design, denture support, and Kennedy classification. Abutment teeth were assessed for plaque index (PI), calculus index (CI), blending on probing (BOP), probing depth (PD), gingival recession (GR), tooth mobility (TM). Level of significance was set at pdenture support of RPD, BOP, PD, PI, GR, CI and TM-index showed no statistically significant difference. Based on the denture design of RPD's, BOP, PD, PI, CI, and TM-index proved no statistically significant difference. Except GR-index according to denture design confirmed statistically significant difference in RPD with clasp pdentures and below the clasp arms in abutment teeth.

  15. Leaving the hospital - your discharge plan

    Science.gov (United States)

    ... patientinstructions/000867.htm Leaving the hospital - your discharge plan To use the sharing features on this page, ... once you leave. This is called a discharge plan. Your health care providers at the hospital will ...

  16. EPA Region 1 No Discharge Zones

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset details No Discharge Zones (NDZ) for New England. Boaters may not discharge waste into these areas. Boundaries were determined mostly by Federal...

  17. Early hospital discharge and early puerperal complications.

    Science.gov (United States)

    Ramírez-Villalobos, Dolores; Hernández-Garduño, Adolfo; Salinas, Aarón; González, Dolores; Walker, Dilys; Rojo-Herrera, Guadalupe; Hernández-Prado, Bernardo

    2009-01-01

    To evaluate the association between time of postpartum discharge and symptoms indicative of complications during the first postpartum week. Women with vaginal delivery at a Mexico City public hospital, without complications before the hospital discharge, were interviewed seven days after delivery. Time of postpartum discharge was classified as early (25 hours). The dependent variable was defined as the occurrence and severity of puerperal complication symptoms. Out of 303 women, 208 (68%) were discharged early. However, women with early discharge and satisfactory prenatal care had lower odds of presenting symptoms in early puerperium than women without early discharge and inadequate prenatal care (OR 0.36; 95% confidence intervals = 0.17-0.76). There was no association between early discharge and symptoms of complications during the first postpartum week; the odds of complications were lower for mothers with early discharge and satisfactory prenatal care.

  18. Aqueous phase hydrogenation of phenol catalyzed by Pd and PdAg on ZrO 2

    Energy Technology Data Exchange (ETDEWEB)

    Resende, Karen A.; Hori, Carla E.; Noronha, Fabio B.; Shi, Hui; Gutierrez, Oliver Y.; Camaioni, Donald M.; Lercher, Johannes A.

    2017-11-01

    Hydrogenation of phenol in aqueous phase was studied over a series of ZrO2-supported Pd catalysts in order to explore the effects of particle size and of Ag addition on the activity of Pd. Kinetic assessments were performed in a batch reactor, on monometallic Pd/ZrO2 samples with different Pd loadings (0.5%, 1% and 2%), as well as on a 1% PdAg/ZrO2 sample. The turnover frequency (TOF) increases with the Pd particle size. The reaction orders in phenol and H2 indicate that the surface coverages by phenol, H2 and their derived intermediates are higher on 0.5% Pd/ZrO2 than on other samples. The activation energy was the lowest on the least active sample (0.5% Pd/ZrO2), while being identical on 1% and 2% Pd/ZrO2 catalysts. Thus, the significantly lower activity of the small Pd particles (1-2 nm on average) in 0.5%Pd/ZrO2 is explained by the unfavorable activation entropies for the strongly bound species. The presence of Ag increases considerably the TOF of the reaction by decreasing the Ea and increasing the coverages of phenol and H2.

  19. Early discharge hospital at home.

    Science.gov (United States)

    Gonçalves-Bradley, Daniela C; Iliffe, Steve; Doll, Helen A; Broad, Joanna; Gladman, John; Langhorne, Peter; Richards, Suzanne H; Shepperd, Sasha

    2017-06-26

    Early discharge hospital at home is a service that provides active treatment by healthcare professionals in the patient's home for a condition that otherwise would require acute hospital inpatient care. This is an update of a Cochrane review. To determine the effectiveness and cost of managing patients with early discharge hospital at home compared with inpatient hospital care. We searched the following databases to 9 January 2017: the Cochrane Effective Practice and Organisation of Care Group (EPOC) register, Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, CINAHL, and EconLit. We searched clinical trials registries. Randomised trials comparing early discharge hospital at home with acute hospital inpatient care for adults. We excluded obstetric, paediatric and mental health hospital at home schemes.   DATA COLLECTION AND ANALYSIS: We followed the standard methodological procedures expected by Cochrane and EPOC. We used the GRADE approach to assess the certainty of the body of evidence for the most important outcomes. We included 32 trials (N = 4746), six of them new for this update, mainly conducted in high-income countries. We judged most of the studies to have a low or unclear risk of bias. The intervention was delivered by hospital outreach services (17 trials), community-based services (11 trials), and was co-ordinated by a hospital-based stroke team or physician in conjunction with community-based services in four trials.Studies recruiting people recovering from strokeEarly discharge hospital at home probably makes little or no difference to mortality at three to six months (risk ratio (RR) 0.92, 95% confidence interval (CI) 0.57 to 1.48, N = 1114, 11 trials, moderate-certainty evidence) and may make little or no difference to the risk of hospital readmission (RR 1.09, 95% CI 0.71 to 1.66, N = 345, 5 trials, low-certainty evidence). Hospital at home may lower the risk of living in institutional setting at six months (RR 0.63, 96% CI

  20. High-temperature stability of Au/Pd/Cu and Au/Pd(P)/Cu surface finishes

    Science.gov (United States)

    Ho, C. E.; Hsieh, W. Z.; Lee, P. T.; Huang, Y. H.; Kuo, T. T.

    2018-03-01

    Thermal reliability of Au/Pd/Cu and Au/Pd(4-6 wt.% P)/Cu trilayers in the isothermal annealing at 180 °C were investigated by X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (TOF-SIMS), and transmission electron microscopy (TEM). The pure Pd film possessed a nanocrystalline structure with numerous grain boundaries, thereby facilitating the interdiffusion between Au and Cu. Out-diffusion of Cu through Pd and Au grain boundaries yielded a significant amount of Cu oxides (CuO and Cu2O) over the Au surface and gave rise to void formation in the Cu film. By contrast, the Pd(P) film was amorphous and served as a good diffusion barrier against Cu diffusion. The results of this study indicated that amorphous Pd(P) possessed better oxidation resistance and thermal reliability than crystalline Pd.

  1. Impact of partially treated sewage effluent on the water quality of ...

    African Journals Online (AJOL)

    Impact of partially treated sewage effluent on the water quality of recipient. Epie Creek in the Niger Delta area of Nigeria was investigated experimentally by analysing the physico-chemical and biological characteristics of the surface water samples collected at four (4) sampling stations: at the effluent discharge point (fall ...

  2. Personality Disorders Associated with Full and Partial Posttraumatic Stress Disorder in the U.S. Population: Results from Wave 2 of the National Epidemiologic Survey on Alcohol and Related Conditions

    Science.gov (United States)

    Pietrzak, Robert H.; Goldstein, Risë B.; Southwick, Steven M.; Grant, Bridget F.

    2010-01-01

    Background While it is well known that personality disorders are associated with trauma exposure and PTSD, limited nationally representative data are available on DSM-IV personality disorders that co-occur with posttraumatic stress disorder (PTSD) and partial PTSD. Methods Face-to-face interviews were conducted with 34,653 adults participating in the Wave 2 National Epidemiologic Survey on Alcohol and Related Conditions. Logistic regression analyses controlling for sociodemographics and additional psychiatric comorbidity evaluated associations of PTSD and partial PTSD with personality disorders. Results Prevalence rates of lifetime PTSD and partial PTSD were 6.4% and 6.6%, respectively. After adjustment for sociodemographic characteristics and additional psychiatric comorbidity, respondents with full PTSD were more likely than trauma controls to meet criteria for schizotypal, narcissistic, and borderline personality disorders (ORs=2.1–2.5); and respondents with partial PTSD were more likely than trauma controls to meet diagnostic criteria for borderline (OR=2.0), schizotypal (OR=1.8), and narcissistic (OR=1.6) PDs. Women with PTSD were more likely than controls to have obsessive-compulsive PD. Women with partial PTSD were more likely than controls to have antisocial PD; and men with partial PTSD were less likely than women with partial PTSD to have avoidant PD. Conclusions PTSD and partial PTSD are associated with borderline, schizotypal, and narcissistic personality disorders. Modestly higher rates of obsessive-compulsive PD were observed among women with full PTSD, and of antisocial PD among women with partial PTSD. PMID:20950823

  3. Capacitor discharges, magnetohydrodynamics, X-rays, ultrasonics

    CERN Document Server

    Früngel, Frank B A

    1965-01-01

    High Speed Pulse Technology, Volume 1: Capacitor Discharges - Magnetohydrodynamics - X-Rays - Ultrasonics deals with the theoretical and engineering problems that arise in the capacitor discharge technique.This book discusses the characteristics of dielectric material, symmetrical switch tubes with mercury filling, and compensation conductor forms. The transformed discharge for highest current peaks, ignition transformer for internal combustion engines, and X-ray irradiation of subjects in mechanical motion are also elaborated. This text likewise covers the transformed capacitor discharge in w

  4. Basic Studies of Distributed Discharge Limiters

    Science.gov (United States)

    2014-02-10

    electron avalanche ionization discharges induced by a focused 110 GHz millimeter-wave beam in atmospheric air. Discharges take place in a free volume of...plasma. 3.1.7 Vacuum Ultraviolet emission from pulsed discharges at atmospheric pressure. Fig. 6. Energy level diagram for molecular and...the utilized spectral simulation software, SPECTRAPLOT. 3.1.8 Non-intrusive diagnostic method for dissociation degree in pulsed discharges

  5. Parachute technique for partial penectomy

    Directory of Open Access Journals (Sweden)

    Fernando Korkes

    2010-04-01

    Full Text Available PURPOSE: Penile carcinoma is a rare but mutilating malignancy. In this context, partial penectomy is the most commonly applied approach for best oncological results. We herein propose a simple modification of the classic technique of partial penectomy, for better cosmetic and functional results. TECHNIQUE: If partial penectomy is indicated, the present technique can bring additional benefits. Different from classical technique, the urethra is spatulated only ventrally. An inverted "V" skin flap with 0.5 cm of extension is sectioned ventrally. The suture is performed with vicryl 4-0 in a "parachute" fashion, beginning from the ventral portion of the urethra and the "V" flap, followed by the "V" flap angles and than by the dorsal portion of the penis. After completion of the suture, a Foley catheter and light dressing are placed for 24 hours. CONCLUSIONS: Several complex reconstructive techniques have been previously proposed, but normally require specific surgical abilities, adequate patient selection and staged procedures. We believe that these reconstructive techniques are very useful in some specific subsets of patients. However, the technique herein proposed is a simple alternative that can be applied to all men after a partial penectomy, and takes the same amount of time as that in the classic technique. In conclusion, the "parachute" technique for penile reconstruction after partial amputation not only improves the appearance of the penis, but also maintains an adequate function.

  6. THE CHALLENGE OF PD PATIENTS: GLUCOSE AND GLUCOSE DEGRADATION PRODUCTS IN PD SOLUTION

    Directory of Open Access Journals (Sweden)

    Yong-Lim Kim

    2012-06-01

    Full Text Available The main osmotic agent found in the peritoneal dialysis (PD solution is glucose. It has been of a wide use for great crystalloid osmotic power at a low concentration, simple metabolism, and excellent safety. On the other hand, anywhere between 60 to 80% of the glucose in the PD solution is absorbed - a 100 to 300 mg of daily glucose absorption. Once into the systemic circulation, glucose can be a cause for metabolic complications including obesity. Indeed, the diabetiform change observed in the peritoneal membrane in the long-term PD patients is believed attributable to the high-concentration glucose in the PD solution. The glucose absorbed from peritoneal cavity raises the risk of ‘glucose toxicity’, leading to insulin resistance and beta cell failure. Clinical similarity can be found in postprandial hyperglycemia, which is known to be associated with oxidative stress, endothelial dysfunction, NF-κb, and inflammation, affecting myocardial blood flow. Moreover, it is a proven independent risk factor of coronary artery disease in patients with type 2 diabetes, particularly of female gender. Though speculative yet, glucose toxicity might explain a higher mortality of PD patients after the first year compared with those on hemodialysis (more so in female, advanced-age patients with diabetes. Also included in the picture are glucose degradation products (GDPs generated along the course of heat sterilization or storage of the PD solution. They have been shown to induce apoptosis of peritoneal mesothelial cells, renal tubular epithelial cells, and endothelial cells, while spurring production of TGF-β and VEGF and facilitating epithelial mesenchymal transition. GDPs provide a stronger reactivity than glucose in the formation of AGEs, a known cause for microvascular complications and arteriosclerosis. Unfortunately, clinical studies using a low-GDP PD solution have provided mixed results on the residual renal function, peritonitis, peritoneal

  7. The PD1:PD-L1/2 Pathway from Discovery to Clinical Implementation.

    Science.gov (United States)

    Bardhan, Kankana; Anagnostou, Theodora; Boussiotis, Vassiliki A

    2016-01-01

    The immune system maintains a critically organized network to defend against foreign particles, while evading self-reactivity simultaneously. T lymphocytes function as effectors and play an important regulatory role to orchestrate the immune signals. Although central tolerance mechanism results in the removal of the most of the autoreactive T cells during thymic selection, a fraction of self-reactive lymphocytes escapes to the periphery and pose a threat to cause autoimmunity. The immune system evolved various mechanisms to constrain such autoreactive T cells and maintain peripheral tolerance, including T cell anergy, deletion, and suppression by regulatory T cells (T Regs ). These effects are regulated by a complex network of stimulatory and inhibitory receptors expressed on T cells and their ligands, which deliver cell-to-cell signals that dictate the outcome of T cell encountering with cognate antigens. Among the inhibitory immune mediators, the pathway consisting of the programed cell death 1 (PD-1) receptor (CD279) and its ligands PD-L1 (B7-H1, CD274) and PD-L2 (B7-DC, CD273) plays an important role in the induction and maintenance of peripheral tolerance and for the maintenance of the stability and the integrity of T cells. However, the PD-1:PD-L1/L2 pathway also mediates potent inhibitory signals to hinder the proliferation and function of T effector cells and have inimical effects on antiviral and antitumor immunity. Therapeutic targeting of this pathway has resulted in successful enhancement of T cell immunity against viral pathogens and tumors. Here, we will provide a brief overview on the properties of the components of the PD-1 pathway, the signaling events regulated by PD-1 engagement, and their consequences on the function of T effector cells.

  8. The PD1: PD-L1/2 pathway from discovery to clinical implementation

    Directory of Open Access Journals (Sweden)

    Kankana Bardhan

    2016-12-01

    Full Text Available The immune system has the difficult challenge of discerning and defending against a diversity of microbial pathogens, while simultaneously avoiding self-reactivity. T lymphocytes function as effectors and regulators of the immune system. While central tolerance mechanism results in deletion of the majority of self-reactive T lymphocytes during thymic selection, a fraction of self reactive lymphocytes escapes to the periphery and retains the potential to inflict destructive autoimmune pathology. The immune system evolved various mechanisms to restrain such auto-reactive T cells and maintain peripheral tolerance, including T cell anergy, deletion, and suppression by regulatory T cells (TRegs. These effects are regulated by a complex network of stimulatory and inhibitory receptors expressed on T cells and their ligands, which deliver cell-to-cell signals that dictate the outcome of T cell encountering with cognate antigens. Among the inhibitory immune mediators, the pathway consisting of the programmed cell death 1 (PD-1 receptor (CD279 and its ligands PD-L1 (B7-H1, CD274 and PD-L2 (B7-DC; CD273 plays a vital role in the induction and maintenance of peripheral tolerance and for the maintenance of T cell homeostasis. In contrast to its beneficial role in self-tolerance, the PD-1: PD-L1/L2 pathway mediates potent inhibitory signals that prevent the expansion and function of T effector cells and have detrimental effects on antiviral and antitumor immunity. Therapeutic targeting of this pathway has resulted in successful enhancement of T cell immunity against viral pathogens and tumors. Here, we will provide a brief overview on the properties of the components of the PD-1 pathway, the signaling events that are regulated by PD-1 triggering, and their consequences on the function of T effector cells.

  9. Avelumab, an anti-PD-L1 antibody, in patients with locally advanced or metastatic breast cancer: a phase 1b JAVELIN Solid Tumor study.

    Science.gov (United States)

    Dirix, Luc Y; Takacs, Istvan; Jerusalem, Guy; Nikolinakos, Petros; Arkenau, Hendrik-Tobias; Forero-Torres, Andres; Boccia, Ralph; Lippman, Marc E; Somer, Robert; Smakal, Martin; Emens, Leisha A; Hrinczenko, Borys; Edenfield, William; Gurtler, Jayne; von Heydebreck, Anja; Grote, Hans Juergen; Chin, Kevin; Hamilton, Erika P

    2018-02-01

    Agents targeting programmed death receptor 1 (PD-1) or its ligand (PD-L1) have shown antitumor activity in the treatment of metastatic breast cancer (MBC). The aim of this study was to assess the activity of avelumab, a PD-L1 inhibitor, in patients with MBC. In a phase 1 trial (JAVELIN Solid Tumor; NCT01772004), patients with MBC refractory to or progressing after standard-of-care therapy received avelumab intravenously 10 mg/kg every 2 weeks. Tumors were assessed every 6 weeks by RECIST v1.1. Adverse events (AEs) were graded by NCI-CTCAE v4.0. Membrane PD-L1 expression was assessed by immunohistochemistry (Dako PD-L1 IHC 73-10 pharmDx). A total of 168 patients with MBC, including 58 patients with triple-negative breast cancer (TNBC), were treated with avelumab for 2-50 weeks and followed for 6-15 months. Patients were heavily pretreated with a median of three prior therapies for metastatic or locally advanced disease. Grade ≥ 3 treatment-related AEs occurred in 13.7% of patients, including two treatment-related deaths. The confirmed objective response rate (ORR) was 3.0% overall (one complete response and four partial responses) and 5.2% in patients with TNBC. A trend toward a higher ORR was seen in patients with PD-L1+ versus PD-L1- tumor-associated immune cells in the overall population (16.7% vs. 1.6%) and in the TNBC subgroup (22.2% vs. 2.6%). Avelumab showed an acceptable safety profile and clinical activity in a subset of patients with MBC. PD-L1 expression in tumor-associated immune cells may be associated with a higher probability of clinical response to avelumab in MBC.

  10. Hydrologic and water quality characteristics of a partially-flooded, abandoned underground coal mine

    International Nuclear Information System (INIS)

    Aljoe, W.W.

    1994-01-01

    The hydrologic and water quality characteristics of a partially flooded, abandoned underground coal mine near Latrobe, PA, were studied to support the development of techniques for in situ abatement of its acidic discharge. A quantitative understanding of the conditions affecting discharge flow was considered to be very important in this regard. Statistical analysis of hydrologic data collected at the site shows that the flow rate of the main discharge (a borehole that penetrates the mine workings just behind a set of portal seals) is a linear function of the height of the mine pool above the borehole outlet. Seepage through or around the portal seals is collected by a set of french drains whose discharge rate is largely independent of the mine pool elevation. This seepage was enhanced after a breakthrough that occurred during a period of unusually high pool levels. The mine pool recharge rate during winter is about 2.5 times greater than that of any other season; recharge rates during spring, summer, and fall are approximately equal. Mine pool and discharge water quality information, along with bromide tracer tests, suggest that the original main entries discharge primarily to the french drains, while the borehole carries the discharge from an unmonitored set of entries northwest of the mains. The water quality of the east french drain discharge may have been improved substantially after seepage through the alkaline materials used to construct the portal seals

  11. Laparoscopic Partial Hepatectomy of Focal Nodular Hyperplasia

    Directory of Open Access Journals (Sweden)

    Mayu Sakata

    2012-11-01

    Full Text Available Focal nodular hyperplasia is a benign liver lesion incidentally discovered with increasing frequency because of the proliferation of imaging studies. Radiographic characterization can diagnose this pathologic lesion and nonoperative therapy is the standard of care. However, surgical resection may be required for diagnostic reasons or symptomatic patients. Depending on the anatomic location of the lesion, biopsy and/or resection can be performed laparoscopically. We herein report the case of a 26-year-old Japanese woman with a hepatic tumor who required a medical examination. Her medical history was negative for alcohol abuse, oral contraceptive administration and trauma. Clinical examination showed no significant symptoms. Ultrasonography, computed tomography and magnetic resonance imaging showed a mass located in the left lateral segment of the liver with a diameter of about 40 mm. It was difficult to diagnose the tumor definitively from these imaging studies, so we performed laparoscopic partial hepatectomy with successive firing of endoscopic staplers. The histopathological diagnosis was focal nodular hyperplasia. Surgical procedures and postoperative course were uneventful and the patient was discharged from the hospital on postoperative day 5.

  12. Radio frequency discharge with dust particles

    NARCIS (Netherlands)

    Chutov, Y. I.; W. J. Goedheer,; Kravchenko, O. Y.; Zuz, V. M.; Yan, M.; Martins, R.; Ferreira, I.; Fortunato, E.; Kroesen, G.

    2000-01-01

    A 1D PIC/MCC method has been developed for computer simulations of low-pressure RF discharges with dust particles using the method for dust-free discharges. A RF discharge in argon with dust particles distributed uniformly in the interelectrode gap is simulated at parameters providing a possibility

  13. 32 CFR 724.117 - Discharge review.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 5 2010-07-01 2010-07-01 false Discharge review. 724.117 Section 724.117 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY PERSONNEL NAVAL DISCHARGE REVIEW BOARD Definitions § 724.117 Discharge review. A nonadversary administrative reappraisal at the level of...

  14. Expansion of a nitrogen discharge by sound

    International Nuclear Information System (INIS)

    Antinyan, M.A.; Galechyan, G.A.; Tavakalyan, L.B.

    1992-01-01

    When the background pressure and the discharge current in a gas discharge are raised the plasma column is tightened up into a filament. Then the discharge occupies a region of the discharge tube whose transverse dimensions are substantially less than those of the tube. This contraction phenomenon in discharges restricts the range of parameters used in various devices to the range of relatively low discharge currents and low gas pressures. This contraction interferes with creating high-power gas lasers, since it acts destructively on the lasing process. In order to suppress filamentation of discharges the working gas has been pumped through the system at high speed, with considerable success. The turbulent mixing in the stream plays an important role in creating an uncontracted discharge at high pressures. The purpose of the present work is to study the possibility of undoing the contraction of a nitrogen discharge, which is one of the main components in the operation of a CO 2 laser, by introducing an intense sound wave in the discharge tube. Discharge contraction and the effect of a sound wave propagating along the plasma column have been investigated experimentally in nitrogen by studying the current-voltage characteristics of a contracted discharge. 6 refs., 3 figs

  15. On regulation of radioactive airborne discharge

    International Nuclear Information System (INIS)

    Stroganov, A.A.; Kuryndin, A.V.; Shapovalov, A.S.; Orlov, M.Yu.

    2013-01-01

    Authors present the Russian regulatory basis of radioactive airborne discharges which was updated after enactment of the Methodology for airborne discharge limits development. Criteria for establishing of airborne discharge limits, scope and other features of methodology are also considered in the article [ru

  16. Effectiveness of community-based rehabilitation after traumatic brain injury for 489 program completers compared with those precipitously discharged.

    Science.gov (United States)

    Altman, Irwin M; Swick, Shannon; Parrot, Devan; Malec, James F

    2010-11-01

    To evaluate outcomes of home- and community-based postacute brain injury rehabilitation (PABIR). Retrospective analysis of program evaluation data for treatment completers and noncompleters. Home- and community-based PABIR conducted in 7 geographically distinct U.S. cities. Patients (N=489) with traumatic brain injury who completed the prescribed course of rehabilitation (completed-course-of-treatment [CCT] group) compared with 114 who were discharged precipitously before program completion (precipitous-discharge [PD] group). PABIR delivered in home and community settings by certified professional staff on an individualized basis. Mayo-Portland Adaptability Inventory (MPAI-4) completed by means of professional consensus on admission and at discharge; MPAI-4 Participation Index at 3- and 12-month follow-up through telephone contact. Analysis of covariance (CCT vs PD group as between-subjects variable, admission MPAI-4 score as covariate) showed significant differences between groups at discharge on the full MPAI-4 (F=82.25; P<.001), Ability Index (F=50.24; P<.001), Adjustment Index (F=81.20; P<.001), and Participation Index (F=59.48; P<.001). A large portion of the sample was lost to follow-up; however, available data showed that group differences remained statistically significant at follow-up. Results provided evidence of the effectiveness of home- and community-based PABIR and that treatment effects were maintained at follow-up. Copyright © 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  17. Partial Transposition on Bipartite System

    International Nuclear Information System (INIS)

    Xi-Jun, Ren; Yong-Jian, Han; Yu-Chun, Wu; Guang-Can, Guo

    2008-01-01

    Many properties of partial transposition are unclear as yet. Here we carefully consider the number of the negative eigenvalues of ρ T (ρ's partial transposition) when ρ is a two-partite state. There is strong evidence to show that the number of negative eigenvalues of ρ T is N(N − 1)/2 at most when ρ is a state in Hilbert space C N C N . For the special case, the 2 × 2 system, we use this result to give a partial proof of the conjecture |ρ T | T ≥ 0. We find that this conjecture is strongly connected with the entanglement of the state corresponding to the negative eigenvalue of ρ T or the negative entropy of ρ

  18. Partial volume effect in MRI

    International Nuclear Information System (INIS)

    Maeda, Munehiro; Yoshiya, Kazuhiko; Suzuki, Eiji

    1989-01-01

    According to the direction and the thickness of the imaging slice in tomography, the border between the tissues becomes unclear (partial volume effect). In the present MRI experiment, we examined border area between fat and water components using phantom in order to investigate the partial volume effect in MRI. In spin echo sequences, the intensity of the border area showed a linear relationship with composition of fat and water. Whereas, in inversion recovery and field echo sequences, we found the parameters to produce an extremely low intensity area at the border region between fat and water. This low intensity area was explained by cancellation of NMR signals from fat and water due to the difference in the direction of magnetic vectors. Clinically, partial volume effect can cause of mis-evaluation of walls, small nodules, tumor capsules and the tumor invasion in the use of inversion recovery and field echo sequences. (author)

  19. Partially composite Goldstone Higgs boson

    DEFF Research Database (Denmark)

    Alanne, Tommi; Franzosi, Diogo Buarque; Frandsen, Mads T.

    2017-01-01

    We consider a model of dynamical electroweak symmetry breaking with a partially composite Goldstone Higgs boson. The model is based on a strongly interacting fermionic sector coupled to a fundamental scalar sector via Yukawa interactions. The SU(4)×SU(4) global symmetry of these two sectors...... is broken to a single SU(4) via Yukawa interactions. Electroweak symmetry breaking is dynamically induced by condensation due to the strong interactions in the new fermionic sector which further breaks the global symmetry SU(4)→Sp(4). The Higgs boson arises as a partially composite state which is an exact...... Goldstone boson in the limit where SM interactions are turned off. Terms breaking the SU(4) global symmetry explicitly generate a mass for the Goldstone Higgs boson. The model realizes in different limits both (partially) composite Higgs and (bosonic) technicolor models, thereby providing a convenient...

  20. Landsliding in partially saturated materials

    Science.gov (United States)

    Godt, J.W.; Baum, R.L.; Lu, N.

    2009-01-01

    [1] Rainfall-induced landslides are pervasive in hillslope environments around the world and among the most costly and deadly natural hazards. However, capturing their occurrence with scientific instrumentation in a natural setting is extremely rare. The prevailing thinking on landslide initiation, particularly for those landslides that occur under intense precipitation, is that the failure surface is saturated and has positive pore-water pressures acting on it. Most analytic methods used for landslide hazard assessment are based on the above perception and assume that the failure surface is located beneath a water table. By monitoring the pore water and soil suction response to rainfall, we observed shallow landslide occurrence under partially saturated conditions for the first time in a natural setting. We show that the partially saturated shallow landslide at this site is predictable using measured soil suction and water content and a novel unified effective stress concept for partially saturated earth materials. Copyright 2009 by the American Geophysical Union.