WorldWideScience

Sample records for partial body measurements

  1. Improvement of measuring techniques with whole-body and partial-body counters

    International Nuclear Information System (INIS)

    Anon

    1998-01-01

    Mathematical simulation methods have been applied for optimizing and standardizing the calibration of whole-body and partial-body counters for any nuclide accumulation in the human body. (orig./CB) [de

  2. Attenuation corrections through energy spectra analysis of whole body and partial body measurements applying gamma spectroscopy; Schwaechungskorrektur bei gammaspektroskopischen Ganz- und Teilkoerpermessungen durch Analyse der Energiespektren

    Energy Technology Data Exchange (ETDEWEB)

    Schelper, L.F.; Lassmann, M.; Haenscheid, H.; Reiners, C. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    1997-12-01

    The study was carried out within the framework of activities for testing means of direct determination of radioactivity levels in the human body due to incorporated, inhomogenously distributed radionuclides. A major task was to derive the average depth of activity distributions, particularly from photon radiation at energies below 500 keV, for the purpose of making suitable attenuation corrections. The paper presents two applicable methods which yield information on the mean depths of activity distributions, obtained through additional analyses of the energy spectra. The analyses are based on measuring the dependence of intensity of the Compton radiation on the length of pathways of the photons penetrating the soft tissue, or on measuring the energy-dependent absorption effects with photons. (orig./CB) [Deutsch] Im Rahmen der direkten Aktivitaetsbestimmung bei inhomogener Radionukliddeposition im menschlichen Koerper mittels Ganz- oder Teilkoerpermessanlagen im klinischen Bereich oder im Strahlenschutz sollte besonders bei Photonenstrahlung mit Energien von weniger als 500 keV eine Ermittlung der mittleren Tiefe der Aktivitaetsverteilung zur Schwaechungskorrektur erfolgen. Im klinischen Umfeld ist es haeufig moeglich, zur Tiefenkorrektur die mittlere Organtiefe und damit die schwaechende Gewebsschicht mittels Ultraschall zu bestimmen. Ergaenzend hierzu werden im Folgenden zwei Methoden vorgestellt, welche Aussagen ueber die mittlere Tiefe von Aktivitaetsverteilungen durch Gewinnung von Zusatzinformationen aus dem Energiespektrum im Rahmen von gamma-spektroskopischen Personenmessungen ermoeglichen. Dazu werden einerseits die Abhaengigkeit der Intensitaet der Comptonstrahlung von der Laenge der Wegstrecke von Photonen durch Weichgewebe und andererseits energieabhaengige Absorptionseffekte bei Photonen als Grundlage herangezogen. (orig.)

  3. Beta dosimetry using partial body dosimeters II. Results of intercomparison measurements of 1998/1999 - PTB report

    International Nuclear Information System (INIS)

    Ambrosi, P.; Helmstaedter, K.

    2000-12-01

    In 1998 the PTB organised a second series of intercomparison measurements for selected beta dosimeters worn on the extremities. In April 1999 these intercomparison measurements and the results obtained were discussed in a one day meeting. The contributions given and the results obtained and the conclusions drawn after extensive discussions are presented in this PTB report. (orig.) [de

  4. Partial body hyperthermia: a potent radioprotector

    International Nuclear Information System (INIS)

    Baydoun, S.; Alya, GH.; Taleb, M.; Mohammad, A.

    1995-12-01

    With the aim to investigate the potential role of some radioprotectors, partial body hyperthermia (PBH) was tested as a protector against the lethality induced by γ irradiation. Two groups of Wistar rats [gr.(1): Females and gr.(2): Males] were treated with PBH by 'dipping' the lower parts of the animals in water-bath at 43 C for 1 hr. Animals were, then, irradiated with a lethal dose of γ radiation (9 Gy) 20 hrs post PBH. Our results show that: -PHB has a protecting role against the lethality induced by γ irradiation with a protection factor [Survival in rats treated with PBH and radiation / survival in rats treated with radiation] of 10 in gr.(1) and 7 in gr.(2) - The role of PBH was more enhanced in females As compared with males. (author). 19 refs., 4 figs., 1 tab

  5. Partial Body Hyperthermia: A Potent radioprotector

    International Nuclear Information System (INIS)

    Baydoun, S.A.; Mohammad, A.; Alya, Gh.; Taleb, M.

    1998-01-01

    With the aim to investigate the potential role of some radioprotectors, partial body hyperthermia (PBH) was tested as a protector against the lethality induced by gamma-irradiation. Two groups of Wistar rats [ gr. (1): females and gr. (2): males] were treated with PBH by dipping the lower parts of the animals in water-bath at 43 degree for 1 hr. Animals were, then, irradiated with a lethal dose of gamma-radiation (9 Gy) 20 hr s post PBH. Our results show that: PBH has a protecting role against the lethality induced by gamma-irradiation with a protection factor [survival in rats treated with PBH and radiation/ survival in rats treated with radiation] of 10 in gr.(1) and 7 in gr. (2). The role of PBH was more enhanced in females as compared with males

  6. A novel technique for partial discharge measurement

    International Nuclear Information System (INIS)

    Farrokh, Fattahi; Navid, Tagizadegan; Ahmad, Zentabchi; Mehdi, Rashidi

    2005-01-01

    Full text : Partial discharges are a sensitive measure of local electrical stress and therefore the measurements is very often used as a quality check of the insulation. The inception of partial discharges gives information on the limit of the electrical strength of the insulating material before a complete discharge between the conductors takes place. Therefore the insulating material can be tested with high stress but without damaging or reducing the performance of the insulation. Also, for partial discharge measurements it should be taken into account that every stress of the insulation will have an influence on the life expectancy of the material, but a reasonable compromise between the stress during the measurement in order to get reliable results and the influence of he lifetime should be found and established in the relevant standard for the particular equipment, for example transformers, cables and so on

  7. FastStats: Body Measurements

    Science.gov (United States)

    ... this? Submit What's this? Submit Button NCHS Home Body Measurements Recommend on Facebook Tweet Share Compartir Data ... 7 MB] Related FastStats Obesity/Overweight Related Links Body Mass Index table CDC Growth Charts National Health ...

  8. Partial pressure measurements with an active spectrometer

    International Nuclear Information System (INIS)

    Brooks, N.H.; Jensen, T.H.; Colchin, R.J.; Maingi, R.; Wade, M.R.; Finkenthal, D.F.; Naumenko, N.; Tugarinov, S.

    1998-07-01

    Partial pressure neutral ga measurements have been made using a commercial Penning gauge in conjunction with an active spectrometer. In prior work utilizing bandpass filters and conventional spectrometers, trace concentrations of the hydrogen isotopes H, D, T and of the noble gases He, Ne and Ar were determined from characteristic spectral lines in the light emitted by the neutral species of these elements. For all the elements mentioned, the sensitivity was limited by spectral contamination from a pervasive background of molecular hydrogen radiation. The active spectrometer overcomes this limitations by means of a digital lock-in method and correlation with reference spectra. Preliminary measurements of an admixture containing a trace amount of neon in deuterium show better than a factor of 20 improvement in sensitivity over conventional techniques. This can be further improved by correlating the relative intensities of multiple lines to sets of reference spectra

  9. Non-invasive measurement of calcium and phosphorus in human body by NAA technique

    International Nuclear Information System (INIS)

    Wang Haiying; Luo Xianqing; Huang Hanqiao

    1995-01-01

    A system of measuring calcium and phosphorus in human legs has been developed by the use of partial-body neutron activation analysis and partial-body counting technique. The results are compared for the normals and osteoporotic patients

  10. Partial Body Weight-Supported Treadmill Training in Spinocerebellar Ataxia.

    Science.gov (United States)

    de Oliveira, Laura Alice Santos; Martins, Camilla Polonini; Horsczaruk, Carlos Henrique Ramos; da Silva, Débora Cristina Lima; Vasconcellos, Luiz Felipe; Lopes, Agnaldo José; Meira Mainenti, Míriam Raquel; Rodrigues, Erika de Carvalho

    2018-01-01

    The motor impairments related to gait and balance have a huge impact on the life of individuals with spinocerebellar ataxia (SCA). Here, the aim was to assess the possibility of retraining gait, improving cardiopulmonary capacity, and challenging balance during gait in SCA using a partial body weight support (BWS) and a treadmill. Also, the effects of this training over functionality and quality of life were investigated. Eight SCA patients were engaged in the first stage of the study that focused on gait training and cardiovascular conditioning. From those, five took part in a second stage of the study centered on dynamic balance training during gait. The first and second stages lasted 8 and 10 weeks, respectively, both comprising sessions of 50 min (2 times per week). The results showed that gait training using partial BWS significantly increased gait performance, treadmill inclination, duration of exercise, and cardiopulmonary capacity in individuals with SCA. After the second stage, balance improvements were also found. Combining gait training and challenging tasks to the postural control system in SCA individuals is viable, well tolerated by patients with SCA, and resulted in changes in capacity for walking and balance.

  11. High-resolution gamma spectroscopy with whole-body and partial-body counters. Experience, recommendations. Report

    International Nuclear Information System (INIS)

    Sahre, P.

    1997-12-01

    The application of high-resolution gamma spectroscopy with whole-body and partial-body counters shows a steadily rising upward trend over the last few years. This induced the ''Arbeitskreis Inkorporationsueberwachung'' of the association ''Fachverband fuer Strahlenschutz e.V.'' to organise a meeting for joint elaboration of a guide on recommended applications of this measuring technique, based on a review of existing experience and results. A key item on the agenda of the meeting was the comparative evaluation of the Ge semiconductor detector and the NaI solid scintillation detector. (orig./CB) [de

  12. Hematopoietic stem cell migration and proliferation after Partial body irradiation

    International Nuclear Information System (INIS)

    Murata, Takashi; Utsumi, Makoto; Hotta, Tomomitsu; Yamada, Hideo

    1983-01-01

    Stem cell migration in hematopoietic recovery after partial body irradiation was investigated with special emphasis on the comparative roles of the bone marrow and the spleen. The number of CFU-S in circulation declined rapidly and reached zero within a day after irradiation, thereafter it increased gradually. This finding suggests the presence of two different phases of stem cell migration. One is a rapid migrating phase in which stem cells are released rapidly within a day after irradiation, and the other is a slow migrating phase. The result of split doses of local body irradiation experiments implicated a role for the spleen distinct from that of the bone marrow in the preferential distribution of stem cells early after irradiation. The cell kinetic study showed that the proliferation of CFU-S occurred actively in irradiated bone marrow and the spleens as compared to that in unirradiated control. But on Day 7 and on Day 10 after irradiation, the proliferation of CFU-S in shielded bone marrow did not occur as actively as those in irradiated areas. The results of our present studies suggest that the spleen is not only the storage pools of migrating stem cells but also the main site of active proliferation of CFU-S in the early period of hematopoietic regeneration. (author)

  13. Measuring radioactivity in the body

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1961-09-15

    Techniques of measuring the total amount of radioactivity in the body of a living person as well as the principal applications of such measurements were reviewed at a Symposium on Whole Body Counting held in Vienna from 12 to 16 June 1961. The whole body counters can be divided into two broad groups: (a) counters for the radiation protection surveillance of the general public and radiation workers, capable of detecting extremely low levels of radioactivity in the human body, and (b) counters for medical research and diagnosis, designed to check the retention and excretion of radioactive substances administered to patients for metabolic and pathological studies. In both cases, the primary requirement is that the counter must be able to measure the total activity in the body. In recent years, there has been a remarkable development of the instruments and techniques for such measurements. One of the main purposes of the symposium in Vienna was to discuss how best to use these highly sophisticated instruments.

  14. Murine partial-body radiation exposure model for biodosimetry studies - Preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Blakely, William F., E-mail: blakely@afrri.usuhs.mil [Uniformed Services University, Armed Forces Radiobiology Research Institute, Scientific Research Department, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States); Sandgren, David J., E-mail: Sandgren@afrri.usuhs.mil [Uniformed Services University, Armed Forces Radiobiology Research Institute, Scientific Research Department, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States); Nagy, Vitaly, E-mail: nagy@afrri.usuhs.mil [Uniformed Services University, Armed Forces Radiobiology Research Institute, Scientific Research Department, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States); Kim, Sung-Yop, E-mail: kimy@afrri.usuhs.mil [Uniformed Services University, Armed Forces Radiobiology Research Institute, Scientific Research Department, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States); Ossetrova, Natalia I., E-mail: ossetrova@afrri.usuhs.mil [Uniformed Services University, Armed Forces Radiobiology Research Institute, Scientific Research Department, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)

    2011-09-15

    The objective of the present study was to establish a murine partial-body radiation exposure model for studies supporting the identification and validation of novel biological dosimetry diagnostic assays. A lead shielding - Plexiglas irradiation apparatus with cutouts to permit irradiation of single-mouse-holder constrained CD2F1 male mice to total-body (3/3), mid- and lower-body (2/3), mid-body only (1/3), and 100% lead shielding sham-treated (0 Gy) controls (0/3) with a 250-kVp X-ray source (dose: 6 Gy, dose rate: 0.50 Gy min{sup -1}) was used. Doses and dose uniformity were measured using alanine - electron paramagnetic resonance (EPR) and ionization chambers. Dosimetry mapping results showed {approx}2 and {approx}12% non-uniformity in the radiation fields for the two smaller (1/3, 2/3) and one larger (3/3) fields, respectively. Hematology results showed no marked differences in neutrophil and platelet counts 1 and 2 days (d) after irradiation. The lymphocyte counts, as expected, demonstrate a progressive decline below baseline levels 1 and 2 d after irradiation with increasing fraction of the body exposed, while the neutrophil to lymphocyte ratios show the inverse effect, with a progressive increase with the fraction of body exposed. The bone marrow biomarker, Flt3 ligand, demonstrated a progressive increase in values with increasing fraction of the body exposed; the 2 d response was enhanced compared to 1 d. The radioresponse 1 d after irradiation for the acute phase reactant protein biomarker, serum amyloid A (SAA) that is synthesized by the liver, was significantly influenced depending on whether the mouse head was in the radiation field. Use of multiple biomarkers based on hematology and proteomic targets provide an enhancement in early-phase partial-body radiation exposure assessment.

  15. Image Reconstruction For Bioluminescence Tomography From Partial Measurement

    OpenAIRE

    Jiang, M.; Zhou, T.; Cheng, J. T.; Cong, W. X.; Wang, Ge

    2007-01-01

    The bioluminescence tomography is a novel molecular imaging technology for small animal studies. Known reconstruction methods require the completely measured data on the external surface, although only partially measured data is available in practice. In this work, we formulate a mathematical model for BLT from partial data and generalize our previous results on the solution uniqueness to the partial data case. Then we extend two of our reconstruction methods for BLT to this case. The first m...

  16. Estimation Of Body Weight From Linear Body Measurements In Two ...

    African Journals Online (AJOL)

    The prediction of body weight from body girth, keel length and thigh length was studied using one hundred Ross and one hundred Anak Titan broilers. Data were collected on the birds from day-old to 9 weeks of age. Body measurement was regressed against body weight at 9 weeks of age using simple linear and ...

  17. Partial dynamical symmetries in quantal many-body systems

    International Nuclear Information System (INIS)

    Van Isacker, P.

    2001-01-01

    Partial dynamical symmetries are associated with Hamiltonians that are partially solvable. The determination of the properties of a quantal system of N interacting particles moving in an external potential requires the solution of the eigenvalue equation associated with a second-quantised Hamiltonian. In many situations of interest the Hamiltonian commutes with transformations that constitute a symmetry algebra G sym . This characteristic opens a way to find all analytically solvable Hamiltonians. The author gives a brief review of some recent developments

  18. SLAC three-body partial wave analysis system

    International Nuclear Information System (INIS)

    Aston, D.; Lasinski, T.A.; Sinervo, P.K.

    1985-10-01

    We present a heuristic description of the SLAC-LBL three-meson partial wave model, and describe how we have implemented it at SLAC. The discussion details the assumptions of the model and the analysis, and emphasizes the methods we have used to prepare and fit the data. 28 refs., 12 figs., 1 tab

  19. Measurements of body protein for clinical investigation

    International Nuclear Information System (INIS)

    Mernagh, J.R.; Harrison, J.E.; McNeill, M.G.; Jeejeebhoy, K.N.; Krishnan, S.S.

    1986-01-01

    Body protein (nitrogen) is determined by bilaterally irradiating the body with neutrons using Pu-Be sources and measuring the resultant 10.8 MeV gamma rays from the reaction 14 N(n,8) 15 N. In the authors lab the whole body can be scanned or separate segments of the body can be measured independently. A nitrogen index has been developed based on body size and is used as a predictor of normal total body nitrogen (TBN). They have found that TBN, when normalized to body size in this way, provides a reliable index of protein status which cannot be accurately determined by body weight, anthropometry, or body potassium measurements. Changes in body composition with age were studied by measuring the composition of 56 healthy female volunteers aged 20-80. Measurements were made for K( 40 K), Ca and N. It was shown that protein and bone mineral decrease with age but that this is not reflected in K or anthropometry measurements. Results of other studies to be presented include: body protein measurements pre and post TPN (total parenteral nutrition), nutritional status of patients on long term CAPD (continuous ambulatory peritoneal dialysis) and changes in body composition as a result of TPN in patients with small cell lung cancer receiving chemotherapy. Clinical results show that indirect measurements of body protein based on weight, potassium, or anthropometry, do not give an accurate measure of body protein. For an accurate measurement, direct measurement of body protein is necessary

  20. A new Bayesian model applied to cytogenetic partial body irradiation estimation

    International Nuclear Information System (INIS)

    Higueras, Manuel; Puig, Pedro; Ainsbury, Elizabeth A.; Vinnikov, Volodymyr A.; Rothkamm, Kai

    2016-01-01

    A new zero-inflated Poisson model is introduced for the estimation of partial body irradiation dose and fraction of body irradiated. The Bayes factors are introduced as tools to help determine whether a data set of chromosomal aberrations obtained from a blood sample reflects partial or whole body irradiation. Two examples of simulated cytogenetic radiation exposure data are presented to demonstrate the usefulness of this methodology in cytogenetic biological dosimetry. (authors)

  1. The theory and measurement of partial discharge transients

    DEFF Research Database (Denmark)

    Pedersen, Aage; Crichton, George C; McAllister, Iain Wilson

    1991-01-01

    A theoretical approach to partial discharge transients is presented. This approach is based on the relationship between the charge induced on the measurement electrode by those created in the interelectrode volume during partial discharge activity. The primary sources for these induced charges ar...... electrode systems of practical interest is illustrated. A discussion of the salient features and practical aspects of the theory is included...

  2. Radiographic analysis of partial or total vertebral body resection

    International Nuclear Information System (INIS)

    Whitten, C.G.; Hammer, G.H.; El-Khoury, G.Y.; Hugus, J.; Weinstein, J.N.

    1991-01-01

    Partial and total vertebrectomies are used in the treatment of primary and metastatic neoplasms of the spine. Serial radiographic studies are crucial in the follow-up of patients with vertebrectomies. This paper presents 33 cases and illustrates radiographic examples of both successful and complicated vertebrectomies, including radiographic signs of local tumor recurrence, loosening, migration or fracture of the hardware or methylmethacrylate, bone graft failure, and progressive spinal instability

  3. Treadmill training with partial body weight support after stroke.

    Science.gov (United States)

    Hesse, Stefan; Werner, Cordula; von Frankenberg, Sophie; Bardeleben, Anita

    2003-02-01

    Treadmill therapy with partial BWS is a promising new approach to improve gait ability after stroke. This task-specific approach enables nonambulatory patients the repetitive practice of complex gait cycles instead of single-limb gait-preparatory maneuvers. Patients walk more symmetrically with less spasticity and better cardiovascular efficiency on the treadmill than with floor walking. Several controlled, clinical studies have shown the potential of treadmill training as a therapeutic intervention for nonambulatory patients with chronic stroke-related hemiplegia. Furthermore, controlled trials in acute stroke survivors have shown that treadmill training is as effective as other physiotherapy approaches that stress the repetitive practice of gait. Controlled multicenter trials comparing locomotor training with conventional therapy will be forthcoming. An electromechanical gait trainer that relieves the strenuous effort of the therapists and provides control of the trunk in a phase-dependent manner is a new technical alternative for gait training in severely impaired stroke patients.

  4. Growth hormone and prolactin responses during partial and whole body warm-water immersions.

    Science.gov (United States)

    Koska, J; Rovensky, J; Zimanova, T; Vigas, M

    2003-05-01

    To elucidate the role of core and skin thermoreceptors in the release of growth hormone (GH) and prolactin (PRL), a sequence of two experiments using whole-body (head-out) and partial (one forearm) hot water immersions was performed. Experiment 1: Nine healthy men were exposed to head-out and partial water immersions (25 min, 38-39 degrees C). Head-out immersion increased the core temperature (38.0 +/- 0.1 vs. 36.7 +/- 0.1 degrees C, P immersion the core temperature was slightly elevated (36.8 +/- 0.1 vs. 36.6 +/- 0.1, P immersed one forearm once in 39 degrees C and once in 38 degrees C water. The measurements were performed in 5-min intervals. The GH concentration increased gradually from the beginning of the immersions (min 10; 39 degrees C: 1.9 +/- 1.0 vs. 0.6 +/- 0.3 ng mL(-1), P Immersion in 38 degrees C water did not induce core temperature changes. Peripheral thermoreceptors are involved in GH release when the body is exposed to elevated environmental temperature while a substantial elevation of core temperature is a precondition of PRL release.

  5. Partial Measurements and the Realization of Quantum-Mechanical Counterfactuals

    Science.gov (United States)

    Paraoanu, G. S.

    2011-07-01

    We propose partial measurements as a conceptual tool to understand how to operate with counterfactual claims in quantum physics. Indeed, unlike standard von Neumann measurements, partial measurements can be reversed probabilistically. We first analyze the consequences of this rather unusual feature for the principle of superposition, for the complementarity principle, and for the issue of hidden variables. Then we move on to exploring non-local contexts, by reformulating the EPR paradox, the quantum teleportation experiment, and the entanglement-swapping protocol for the situation in which one uses partial measurements followed by their stochastic reversal. This leads to a number of counter-intuitive results, which are shown to be resolved if we give up the idea of attributing reality to the wavefunction of a single quantum system.

  6. Linear algebraic theory of partial coherence: discrete fields and measures of partial coherence.

    Science.gov (United States)

    Ozaktas, Haldun M; Yüksel, Serdar; Kutay, M Alper

    2002-08-01

    A linear algebraic theory of partial coherence is presented that allows precise mathematical definitions of concepts such as coherence and incoherence. This not only provides new perspectives and insights but also allows us to employ the conceptual and algebraic tools of linear algebra in applications. We define several scalar measures of the degree of partial coherence of an optical field that are zero for full incoherence and unity for full coherence. The mathematical definitions are related to our physical understanding of the corresponding concepts by considering them in the context of Young's experiment.

  7. Diagnosis of partial body radiation exposure in mice using peripheral blood gene expression profiles.

    Directory of Open Access Journals (Sweden)

    Sarah K Meadows

    2010-07-01

    Full Text Available In the event of a terrorist-mediated attack in the United States using radiological or improvised nuclear weapons, it is expected that hundreds of thousands of people could be exposed to life-threatening levels of ionizing radiation. We have recently shown that genome-wide expression analysis of the peripheral blood (PB can generate gene expression profiles that can predict radiation exposure and distinguish the dose level of exposure following total body irradiation (TBI. However, in the event a radiation-mass casualty scenario, many victims will have heterogeneous exposure due to partial shielding and it is unknown whether PB gene expression profiles would be useful in predicting the status of partially irradiated individuals. Here, we identified gene expression profiles in the PB that were characteristic of anterior hemibody-, posterior hemibody- and single limb-irradiation at 0.5 Gy, 2 Gy and 10 Gy in C57Bl6 mice. These PB signatures predicted the radiation status of partially irradiated mice with a high level of accuracy (range 79-100% compared to non-irradiated mice. Interestingly, PB signatures of partial body irradiation were poorly predictive of radiation status by site of injury (range 16-43%, suggesting that the PB molecular response to partial body irradiation was anatomic site specific. Importantly, PB gene signatures generated from TBI-treated mice failed completely to predict the radiation status of partially irradiated animals or non-irradiated controls. These data demonstrate that partial body irradiation, even to a single limb, generates a characteristic PB signature of radiation injury and thus may necessitate the use of multiple signatures, both partial body and total body, to accurately assess the status of an individual exposed to radiation.

  8. Nutritional assessment with body composition measurements

    International Nuclear Information System (INIS)

    Shizgal, H.M.

    1987-01-01

    The measurement of body composition by multiple isotope dilution provides an accurate and precise measure of both the nutritional state and the response to nutritional support. A multiple isotope dilution technique has been developed that permits measurement of the three major components of body composition: body fat, extracellular mass (ECM), and body cell mass (BCM). Normal body composition was defined by data obtained in 25 healthy volunteers. Malnutrition is characterized by a loss of BCM and an expansion of the ECM, and as a result the lean body mass is not significantly different from normal. The loss of body weight with malnutrition therefore often reflects the loss of body fat. The utility of body composition measurements was demonstrated by determining the effect of total parenteral nutrition on body composition to determine the relationship between caloric intake and the change in the BCM. A statistically significant relationship was developed which demonstrated that a caloric intake in the range of 30-40 cal/kg/day is required for maintenance. To restore a depleted or malnourished BCM requires a caloric intake in excess of that required for maintenance. The measurement of body composition by multiple isotope dilution is complex and time consuming, and requires specialized laboratory facilities and specially trained personnel. As a result, these measurements are not suited for routine patient management, but should rather be reserved for research purposes

  9. Magnetic Evidence for a Partially Differentiated Carbonaceous Chondrite Parent Body and Possible Implications for Asteroid 21 Lutetia

    Science.gov (United States)

    Weiss, Benjamin; Carporzen, L.; Elkins-Tanton, L.; Shuster, D. L.; Ebel, D. S.; Gattacceca, J.; Binzel, R. P.

    2010-10-01

    The origin of remanent magnetization in the CV carbonaceous chondrite Allende has been a longstanding mystery. The possibility of a core dynamo like that known for achondrite parent bodies has been discounted because chondrite parent bodies are assumed to be undifferentiated. Here we report that Allende's magnetization was acquired over several million years (Ma) during metasomatism on the parent planetesimal in a > 20 microtesla field 8-9 Ma after solar system formation. This field was present too recently and directionally stable for too long to have been the generated by the protoplanetary disk or young Sun. The field intensity is in the range expected for planetesimal core dynamos (Weiss et al. 2010), suggesting that CV chondrites are derived from the outer, unmelted layer of a partially differentiated body with a convecting metallic core (Elkins-Tanton et al. 2010). This suggests that asteroids with differentiated interiors could be present today but masked under chondritic surfaces. In fact, CV chondrites are spectrally similar to many members of the Eos asteroid family whose spectral diversity has been interpreted as evidence for a partially differentiated parent asteroid (Mothe-Diniz et al. 2008). CV chondrite spectral and polarimetric data also resemble those of asteroid 21 Lutetia (e.g., Belskaya et al. 2010), recently encountered by the Rosetta spacecraft. Ground-based measurements of Lutetia indicate a high density of 2.4-5.1 g cm-3 (Drummond et al. 2010), while radar data seem to rule out a metallic surface composition (Shepard et al. 2008). If Rosetta spacecraft measurements confirm a high density and a CV-like surface composition for Lutetia, then we propose Lutetia may be an example of a partially differentiated carbonaceous chondrite parent body. Regardless, the very existence of primitive achondrites, which contain evidence of both relict chondrules and partial melting, are prima facie evidence for the formation of partially differentiated bodies.

  10. A new method for body fat evaluation, body adiposity index, is useful in women with familial partial lipodystrophy.

    Science.gov (United States)

    Godoy-Matos, Amélio F; Moreira, Rodrigo O; Valerio, Cynthia M; Mory, Patricia B; Moises, Regina S

    2012-02-01

    BMI is a widely used method to evaluate adiposity. However, it has several limitations, particularly an inability to differentiate lean from fat mass. A new method, body adiposity index (BAI), has been recently proposed as a new measurement capable to determine fat excess better than BMI. The aim of this study was to investigate BAI as a mean to evaluate adiposity in a group of women with familial partial lipodystrophy (FPLD) and compare it with BMI. Thirteen women with FLPD Dunnigan type (FPLD2) and 13 healthy volunteers matched by age and BMI were studied. Body fat content and distribution were analyzed by dual X-ray absorptiometry (DXA). Plasma leptin was also measured. BAI was significantly lower in FPLD2 in comparison to control group (24.6 ± 1.5 vs. 30.4 ± 4.3; P < 0.001) and presented a more significant correlation with total fat (%) (r = 0.71; P < 0.001) and fat Mass (g) (r = 0.80; P < 0.001) than BMI (r = 0.27; P = 0.17 for total fat and r = 0.52; P = 0.006 for fat mass). There was a correlation between leptin and BAI (r = 0.57; P = 0.01), [corrected] but not between leptin and BMI. In conclusion, BAI was able to catch differences in adiposity in a sample of FPLD2 patients. It also correlated better with leptin levels than BMI. Therefore, we provide further evidence that BAI may become a more reliable indicator of fat mass content than the currently available measurements.

  11. Understanding Rasch Measurement: Partial Credit Model and Pivot Anchoring.

    Science.gov (United States)

    Bode, Rita K.

    2001-01-01

    Describes the Rasch measurement partial credit model, what it is, how it differs from other Rasch models, and when and how to use it. Also describes the calibration of instruments with increasingly complex items. Explains pivot anchoring and illustrates its use and describes the effect of pivot anchoring on step calibrations, item hierarchy, and…

  12. Microwave measurements of water vapor partial pressure at high temperatures

    International Nuclear Information System (INIS)

    Latorre, V.R.

    1991-01-01

    One of the desired parameters in the Yucca Mountain Project is the capillary pressure of the rock comprising the repository. This parameter is related to the partial pressure of water vapor in the air when in equilibrium with the rock mass. Although there are a number of devices that will measure the relative humidity (directly related to the water vapor partial pressure), they generally will fail at temperatures on the order of 150C. Since thee author has observed borehole temperatures considerably in excess of this value in G-Tunnel at the Nevada Test Site (NTS), a different scheme is required to obtain the desired partial pressure data at higher temperatures. This chapter presents a microwave technique that has been developed to measure water vapor partial pressure in boreholes at temperatures up to 250C. The heart of the system is a microwave coaxial resonator whose resonant frequency is inversely proportional to the square root of the real part of the complex dielectric constant of the medium (air) filling the resonator. The real part of the dielectric constant of air is approximately equal to the square of the refractive index which, in turn, is proportional to the partial pressure of the water vapor in the air. Thus, a microwave resonant cavity can be used to measure changes in the relative humidity or partial pressure of water vapor in the air. Since this type of device is constructed of metal, it is able to withstand very high temperatures. The actual limitation is the temperature limit of the dielectric material in the cable connecting the resonator to its driving and monitoring equipment-an automatic network analyzer in our case. In the following sections, the theory of operation, design, construction, calibration and installation of the microwave diagnostics system is presented. The results and conclusions are also presented, along with suggestions for future work

  13. System Entropy Measurement of Stochastic Partial Differential Systems

    Directory of Open Access Journals (Sweden)

    Bor-Sen Chen

    2016-03-01

    Full Text Available System entropy describes the dispersal of a system’s energy and is an indication of the disorder of a physical system. Several system entropy measurement methods have been developed for dynamic systems. However, most real physical systems are always modeled using stochastic partial differential dynamic equations in the spatio-temporal domain. No efficient method currently exists that can calculate the system entropy of stochastic partial differential systems (SPDSs in consideration of the effects of intrinsic random fluctuation and compartment diffusion. In this study, a novel indirect measurement method is proposed for calculating of system entropy of SPDSs using a Hamilton–Jacobi integral inequality (HJII-constrained optimization method. In other words, we solve a nonlinear HJII-constrained optimization problem for measuring the system entropy of nonlinear stochastic partial differential systems (NSPDSs. To simplify the system entropy measurement of NSPDSs, the global linearization technique and finite difference scheme were employed to approximate the nonlinear stochastic spatial state space system. This allows the nonlinear HJII-constrained optimization problem for the system entropy measurement to be transformed to an equivalent linear matrix inequalities (LMIs-constrained optimization problem, which can be easily solved using the MATLAB LMI-toolbox (MATLAB R2014a, version 8.3. Finally, several examples are presented to illustrate the system entropy measurement of SPDSs.

  14. Ultrasound gel minimizes third body debris with partial hardware removal in joint arthroplasty

    Directory of Open Access Journals (Sweden)

    Aidan C. McGrory

    2017-03-01

    Full Text Available Hundreds of thousands of revision surgeries for hip, knee, and shoulder joint arthroplasties are now performed worldwide annually. Partial removal of hardware during some types of revision surgeries may create significant amounts of third body metal, polymer, or bone cement debris. Retained debris may lead to a variety of negative health effects including damage to the joint replacement. We describe a novel technique for the better containment and easier removal of third body debris during partial hardware removal. We demonstrate hardware removal on a hip joint model in the presence and absence of water-soluble gel to depict the reduction in metal debris volume and area of spread.

  15. Partial body irradiation of small laboratory animals with an industrial X-ray tube

    International Nuclear Information System (INIS)

    Frenzel, Thorsten; Kruell, Andreas; Grohmann, Carsten; Schumacher, Udo

    2014-01-01

    Dedicated precise small laboratory animal irradiation sources are needed for basic cancer research and to meet this need expensive high precision radiation devices have been developed. To avoid such expenses a cost efficient way is presented to construct a device for partial body irradiation of small laboratory animals by adding specific components to an industrial X-ray tube. A custom made radiation field tube was added to an industrial 200 kV X-ray tube. A light field display as well as a monitor ionization chamber were implemented. The field size can rapidly be changed by individual inserts of MCP96 that are used for secondary collimation of the beam. Depth dose curves and cross sectional profiles were determined with the use of a custom made water phantom. More components like positioning lasers, a custom made treatment couch, and a commercial isoflurane anesthesia unit were added to complete the system. With the accessories described secondary small field sizes down to 10 by 10 mm 2 (secondary collimator size) could be achieved. The dosimetry of the beam was constructed like those for conventional stereotactical clinical linear accelerators. The water phantom created showed an accuracy of 1 mm and was well suited for all measurements. With the anesthesia unit attached to the custom made treatment couch the system is ideal for the radiation treatment of small laboratory animals like mice. It was feasible to shrink the field size of an industrial X-ray tube from whole animal irradiation to precise partial body irradiation of small laboratory animals. Even smaller secondary collimator sizes than 10 by 10 mm 2 are feasible with adequate secondary collimator inserts. Our custom made water phantom was well suited for the basic dosimetry of the X-ray tube.

  16. Exploring point-cloud features from partial body views for gender classification

    Science.gov (United States)

    Fouts, Aaron; McCoppin, Ryan; Rizki, Mateen; Tamburino, Louis; Mendoza-Schrock, Olga

    2012-06-01

    In this paper we extend a previous exploration of histogram features extracted from 3D point cloud images of human subjects for gender discrimination. Feature extraction used a collection of concentric cylinders to define volumes for counting 3D points. The histogram features are characterized by a rotational axis and a selected set of volumes derived from the concentric cylinders. The point cloud images are drawn from the CAESAR anthropometric database provided by the Air Force Research Laboratory (AFRL) Human Effectiveness Directorate and SAE International. This database contains approximately 4400 high resolution LIDAR whole body scans of carefully posed human subjects. Success from our previous investigation was based on extracting features from full body coverage which required integration of multiple camera images. With the full body coverage, the central vertical body axis and orientation are readily obtainable; however, this is not the case with a one camera view providing less than one half body coverage. Assuming that the subjects are upright, we need to determine or estimate the position of the vertical axis and the orientation of the body about this axis relative to the camera. In past experiments the vertical axis was located through the center of mass of torso points projected on the ground plane and the body orientation derived using principle component analysis. In a natural extension of our previous work to partial body views, the absence of rotational invariance about the cylindrical axis greatly increases the difficulty for gender classification. Even the problem of estimating the axis is no longer simple. We describe some simple feasibility experiments that use partial image histograms. Here, the cylindrical axis is assumed to be known. We also discuss experiments with full body images that explore the sensitivity of classification accuracy relative to displacements of the cylindrical axis. Our initial results provide the basis for further

  17. Effects of whole-body and partial-body x irradiation upon epidermal mitotic activity during wound healing in mouse skin

    International Nuclear Information System (INIS)

    Kobayashi, K.

    1977-01-01

    Mitotic activity of normal (unwounded) and wounded skin was measured in the control (nonirradiated) and whole-body or partial-body x-irradiated mouse. Higher mitotic activity in the anterior than in the posterior region of the body was found in both the normal and the wounded skin of the control mouse. Whole-body irradiation (500 R) depressed completely the mitotic activity of normal skin 2 to 4 days after irradiation. In spite of this depression in mitotic activity, a surgical incision made 1 to 3 days after irradiation could induce a burst of proliferation after an inhibition of an initial mitosis increase. When the animals were partially irradiated with 500 R 3 days before wounding, it was shown that mitosis at 24 hr after wounding was inhibited markedly by the local effect of irradiation and that mitosis also could be inhibited diversely by the abscopal effect of irradiation. Because of a close similarity of sequential mitotic patterns between whole-body-irradiated and flapped-skin-only-irradiated groups (direct irradiation), the effect of irradiation upon mitosis was considered to be primarily local. Some discussions were made concerning the possible reasons which made a difference in mitotic patterns between the head-only-irradiated group, the irradiated group including the head and other parts of the body except for the skin flap

  18. Treadmill Training with Partial Body-Weight Support in Children with Cerebral Palsy: A Systematic Review

    Science.gov (United States)

    Mutlu, Akmer; Krosschell, Kristin; Spira, Deborah Gaebler

    2009-01-01

    OKAim: The aim of this systematic review was to examine the literature on the effects of partial body-weight support treadmill training (PBWSTT) in children with cerebral palsy (CP) on functional outcomes and attainment of ambulation. Method: We searched the relevant literature from 1950 to July 2007. We found eight studies on the use of PWSBTT on…

  19. Treadmill training with partial body-weight support after anterior cruciate ligament reconstruction: a randomized controlled trial.

    Science.gov (United States)

    Luo, Yuan; Shen, Weizhong; Jiang, Zhong; Sha, Jiao

    2016-12-01

    [Purpose] To compare the effects of treadmill training with partial body weight support (TTPBWS) and conventional physical therapy (PT) on subjects with anterior cruciate ligament reconstructions. [Subjects and Methods] A total of 40 subjects were randomly allocated to either a treatment group or a control group. Subjects received either treadmill training with partial body weight support (treatment group) or conventional physical therapy (control group). The circumferences of the lower extremities, Holden classifications, 10-meter walking times and the International Knee Documentation Committee (IKDC) scores were compared at 12 and 24 weeks post-operation. The knee joint stability was tested at 24 weeks post-operation using a KT-1000. [Results] Significant differences were found between the two groups at the 12 weeks post-operation. For most of the measures, there was no significant difference between the groups at 24 weeks post-operation. Interestingly, for most of the measures, there was no significant difference between their values in the treatment group at 12 weeks and their values in the control group at 24 weeks post-operation. [Conclusion] The function of a subject's lower extremities can be improved and the improvement was clearly accelerated by the intervention of treadmill training with partial body weight support, without compromising the stability of the knee joints in a given follow-up period.

  20. Experimental studies on cytogenetic dosimetry for in vitro simulated and in vivo partial body exposure

    International Nuclear Information System (INIS)

    Han Baoguang; Chen Di; Jin Cuizhen; Liu Xiulin; Luo Yisheng

    1993-01-01

    The feasibility was examined of the contaminated Poisson distribution method as applied to dose estimation of in vitro simulated and in vivo partial body exposure of New Zealand rabbits. For this purpose, the preparatory experiments were conducted. Aberration yields were obtained for mixed cultures prepared from normal and irradiated peripheral lymphocytes with volume ratio 3 to 7 and for pure cultures of irradiated cells. Comparison of the dicentric yields from these two types of cultures indicated that the probability of cultured irradiated cells entering M 1 phase was exponentially decreased as the absorbed dose increased with a D 37 value of 2.41 Gy. Analysis of the dicentric yields obtained from pure cultures demonstrated that the dose-response relationship of dicentric yields was represented by a linear-quadratic model. Partial body exposures with irradiated fractions ranging from 90% to 30% were simulated by irradiating rabbit blood in vitro with 5 Gy 60 Co γ rays. The contaminated Poisson distribution method was utilized to derive the fraction of irradiated blood in the mixed culture and its absorbed dose. The results showed the estimations are in good agreement with true values. Moreover, the same results were arrived at for in vivo partial body irradiation in spite of many complicated factors inhered. Two groups of rabbits were irradiated in vivo on right halves along their backbones at 3.6 Gy and 5.0 Gy respectively. Heart blood was sampled 24 hours later. The result analysed by the same method approximated the true values. Before the in vivo irradiation, heart blood was sampled and irradiated in vitro to simulate half body and whole body exposure, which provided self-control for its in vivo data. These offered further proof for the previous results of in vitro simulated partial body exposure

  1. Assessment of body temperature measurement options.

    Science.gov (United States)

    Sund-Levander, Märtha; Grodzinsky, Ewa

    Assessment of body temperature is important for decisions in nursing care, medical diagnosis, treatment and the need of laboratory tests. The definition of normal body temperature as 37°C was established in the middle of the 19th century. Since then the technical design and the accuracy of thermometers has been much improved. Knowledge of physical influence on the individual body temperature, such as thermoregulation and hormones, are still not taken into consideration in body temperature assessment. It is time for a change; the unadjusted mode should be used, without adjusting to another site and the same site of measurement should be used as far as possible. Peripheral sites, such as the axillary and the forehead site, are not recommended as an assessment of core body temperature in adults. Frail elderly individuals might have a low normal body temperature and therefore be at risk of being assessed as non-febrile. As the ear site is close to the hypothalamus and quickly responds to changes in the set point temperature, it is a preferable and recommendable site for measurement of body temperature.

  2. One session of partial-body cryotherapy (-110 °C) improves muscle damage recovery.

    Science.gov (United States)

    Ferreira-Junior, J B; Bottaro, M; Vieira, A; Siqueira, A F; Vieira, C A; Durigan, J L Q; Cadore, E L; Coelho, L G M; Simões, H G; Bemben, M G

    2015-10-01

    To evaluate the effects of a single session of partial-body cryotherapy (PBC) on muscle recovery, 26 young men performed a muscle-damaging protocol that consisted of five sets of 20 drop jumps with 2-min rest intervals between sets. After the exercise, the PBC group (n = 13) was exposed to 3 min of PBC at -110 °C, and the control group (n = 13) was exposed to 3 min at 21 °C. Anterior thigh muscle thickness, isometric peak torque, and muscle soreness of knee extensors were measured pre, post, 24, 48, 72, and 96 h following exercise. Peak torque did not return to baseline in control group (P  0.05). Peak torque was also higher after PBC at 72 and 96 h compared with control group (P < 0.05). Muscle thickness increased after 24 h in the control group (P < 0.05) and was significantly higher compared with the PBC group at 24 and 96 h (P < 0.05). Muscle soreness returned to baseline for the PBC group at 72 h compared with 96 h for controls. These results indicate that PBC after strenuous exercise may enhance recovery from muscle damage. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Measurement of Radioactivity in the Human Body

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Nilsson, I

    1960-12-15

    A body counter with a steel room and a 4-inch-diameter by 4-inch thick Nal scintillation counter has been in operation since February 1958. It is used to control the internal contamination in people working with radioactive materials. Measurements have also been made on the natural activity in the human body. The average cesium-137/potassium ratio in a group of Swedish males was in May 1959 73 {mu}{mu}c per gram of body potassium and in June 1960 55 {mu}{mu}c per gram of body potassium. The cessation of the nuclear bomb tests has caused a decrease in the cesium level in people. This gives some information of how cesium is entering the biosphere.

  4. Sensing Movement: Microsensors for Body Motion Measurement

    Directory of Open Access Journals (Sweden)

    Hansong Zeng

    2011-01-01

    Full Text Available Recognition of body posture and motion is an important physiological function that can keep the body in balance. Man-made motion sensors have also been widely applied for a broad array of biomedical applications including diagnosis of balance disorders and evaluation of energy expenditure. This paper reviews the state-of-the-art sensing components utilized for body motion measurement. The anatomy and working principles of a natural body motion sensor, the human vestibular system, are first described. Various man-made inertial sensors are then elaborated based on their distinctive sensing mechanisms. In particular, both the conventional solid-state motion sensors and the emerging non solid-state motion sensors are depicted. With their lower cost and increased intelligence, man-made motion sensors are expected to play an increasingly important role in biomedical systems for basic research as well as clinical diagnostics.

  5. Measurement of Radioactivity in the Human Body

    International Nuclear Information System (INIS)

    Andersson, I.Oe.; Nilsson, I.

    1960-12-01

    A body counter with a steel room and a 4-inch-diameter by 4-inch thick Nal scintillation counter has been in operation since February 1958. It is used to control the internal contamination in people working with radioactive materials. Measurements have also been made on the natural activity in the human body. The average cesium-137/potassium ratio in a group of Swedish males was in May 1959 73 μμc per gram of body potassium and in June 1960 55 μμc per gram of body potassium. The cessation of the nuclear bomb tests has caused a decrease in the cesium level in people. This gives some information of how cesium is entering the biosphere

  6. Biological dose estimation of partial body exposures in cervix cancer patients

    International Nuclear Information System (INIS)

    Di Giorgio, Marina; Nasazzi, Nora B.; Taja, Maria R.; Roth, B.; Sardi, M.; Menendez, P.

    2000-01-01

    At present, unstable chromosome aberrations analysis in peripheral blood lymphocytes is the most sensitive method to provide a biological estimation of the dose in accidental radiation over exposures. The assessment of the dose is particularly reliable in cases of acute, uniform, whole-body exposures or after irradiation of large parts of the body. However, the scenarios of most radiation accidents result in partial-body exposures or non-uniform dose distribution, leading to a differential exposure of lymphocytes in the body. Inhomogeneity produces a yield of dicentrics, which does not conform to a Poisson distribution, but is generally over dispersed. This arises because those lymphocytes in tissues outside the radiation field will not be damaged. Most of the lymphocytes (80 %) belong to the 'redistributional pool' (lymphatic tissues and other organs) and made recirculate into peripheral blood producing a mixed irradiated and unirradiated population of lymphocytes. So-called over dispersion, with a variance greater than the mean, can be taken as an indication of non-uniform exposure. The main factors operating in vivo partial-body irradiation may be the location and size of the irradiation field and, at high doses, various cellular reactions such as reduced blast transformation, mitotic delay or interphase death may contribute. For partial-body exposures, mathematical-statistical analysis of chromosome aberration data can be performed to derive a dose estimate for the irradiated fraction of the body, been more realistic than to quote a mean equivalent uniform whole body dose. The 'Contaminated Poisson' method of Dolphin or the Qdr method of Sasaki, both based on similar principles, can achieve this. Contaminated Poisson considers the over dispersed distribution of dicentrics among all the cells scored. The observed distribution is considered to be the sum of a Poisson distribution, which represents the irradiated fraction of the body, and the remaining unexposed

  7. Response of stem cell system to whole body and partial body irradiation

    International Nuclear Information System (INIS)

    Gidali, J.

    1975-01-01

    The pluripotent stem cell system, though being distributed in the body, reacts homogeneously to irradiation. This homogeneity is controlled by short-range (local) and long-range (humoral) regulations acting primarily on pluripotent and committed stem cells. Migration of stem cells from unirradiated to irradiated areas may play a role in the regeneration processes even if local regeneration may also occur. Migration induction as well as proliferation induction in the shielded area do not seem to be specific radiation-induced reactions. Both may be influenced either by some physiological regulators released after irradiation in a higher quantity or by some non-specific triggering agents. Both repeated and continuous irradiation induce the establishment of a new steady state. In the steady state after repeated sublethal irradiations, the CFU count stays at a suboptimal level either as a consequence of an increased differentiation or of some undefined damage in milieu control. In the new steady state during continuous irradiation, the number of mature elements in blood is close to the normal while CFU population is reduced to less than 2 percent of its original level

  8. DNA damage focus analysis in blood samples of minipigs reveals acute partial body irradiation.

    Directory of Open Access Journals (Sweden)

    Andreas Lamkowski

    Full Text Available Radiation accidents frequently involve acute high dose partial body irradiation leading to victims with radiation sickness and cutaneous radiation syndrome that implements radiation-induced cell death. Cells that are not lethally hit seek to repair ionizing radiation (IR induced damage, albeit at the expense of an increased risk of mutation and tumor formation due to misrepair of IR-induced DNA double strand breaks (DSBs. The response to DNA damage includes phosphorylation of histone H2AX in the vicinity of DSBs, creating foci in the nucleus whose enumeration can serve as a radiation biodosimeter. Here, we investigated γH2AX and DNA repair foci in peripheral blood lymphocytes of Göttingen minipigs that experienced acute partial body irradiation (PBI with 49 Gy (± 6% Co-60 γ-rays of the upper lumbar region. Blood samples taken 4, 24 and 168 hours post PBI were subjected to γ-H2AX, 53BP1 and MRE11 focus enumeration. Peripheral blood lymphocytes (PBL of 49 Gy partial body irradiated minipigs were found to display 1-8 DNA damage foci/cell. These PBL values significantly deceed the high foci numbers observed in keratinocyte nuclei of the directly γ-irradiated minipig skin regions, indicating a limited resident time of PBL in the exposed tissue volume. Nonetheless, PBL samples obtained 4 h post IR in average contained 2.2% of cells displaying a pan-γH2AX signal, suggesting that these received a higher IR dose. Moreover, dispersion analysis indicated partial body irradiation for all 13 minipigs at 4 h post IR. While dose reconstruction using γH2AX DNA repair foci in lymphocytes after in vivo PBI represents a challenge, the DNA damage focus assay may serve as a rapid, first line indicator of radiation exposure. The occurrence of PBLs with pan-γH2AX staining and of cells with relatively high foci numbers that skew a Poisson distribution may be taken as indicator of acute high dose partial body irradiation, particularly when samples are available

  9. Dipeptidyl peptidase-4 levels are increased and partially related to body fat distribution in patients with familial partial lipodystrophy type 2.

    Science.gov (United States)

    Valerio, Cynthia Melissa; de Almeida, Juliana Severo; Moreira, Rodrigo Oliveira; Aguiar, Luiza Barreto S; Siciliano, Priscila O; Carvalho, Denise P; Godoy-Matos, Amelio F

    2017-01-01

    Dipeptidyl peptidase-4 (DDP4) is an enzyme responsible for glucagon-like peptide-1 inactivation and plays an important role in glucose metabolism. The aim of this study was to evaluate DPP4 levels in patients with familial partial lipodystrophy type 2 (FPLD2) and correlate it with body fat distribution. Fourteen patients with FPLD2 were selected to participate in this study and matched to a healthy control group (n = 8). All participants had anthropometrical data registered. Body adiposity index (BAI) was used to evaluate fat distribution in this population. Body fat content and distribution were analyzed by dual X-ray absorptiometry (DXA). Biochemical exams, including DPP4 levels, were performed in all individuals. Despite the same body mass index, lipodystrophic patients had a significant lower hip (median 92.0 vs 94.5; p = 0.028), HDL cholesterol (42.6 ± 10.4 vs 66.1 ± 16.0; p correlation was found between DPP4 levels and percentage of total body fat (r = 0.86; p = 0.0025) and android fat (r = 0.78; p = 0.014). Patients with FPLD2 exhibit an increase in DDP4 levels in comparison to a healthy control group. The increase in the levels of this enzyme does not seem to be related to the diagnosis of diabetes and might be associated with an increase in central fat (estimated using BAI and measured using DXA). These results might be used to reinforce the concept that DDP4 is an adipokine related to central fat distribution.

  10. Effects of partial-body cryotherapy (- 110°C) on muscle recovery between high-intensity exercise bouts.

    Science.gov (United States)

    Ferreira-Junior, J B; Bottaro, M; Vieira, C A; Soares, S R S; Vieira, A; Cleto, V A; Cadore, E L; Coelho, D B; Simoes, H G; Brown, L E

    2014-12-01

    The aim of this study was to evaluate the effects of a single partial-body cryotherapy bout between training sessions on strength recovery. 12 young men (23.9±5.9 years) were randomly exposed to 2 different conditions separated by 7 days: 1) Partial-body cryotherapy (subjects were exposed to 3 min of partial-body cryotherapy at - 110 °C between 2 high-intensity training sessions); 2) Control (subjects were not exposed to partial-body cryotherapy between 2 high-intensity training sessions). Subjects were exposed to partial-body cryotherapy after the first training session. The 2 knee extension high-intensity training sessions were separated by a 40-min rest interval. Knee extension training consisted of 6 sets of 10 repetitions at 60°.s(-1) for concentric actions and 6 sets of 10 at 180.s(-1) for eccentric actions. The decrease in eccentric peak torque and total work was significantly (pcryotherapy (5.6 and 2%, respectively) when compared to control (16 and 11.6%, respectively). However, the decrease in concentric peak torque and total work was not different (p>0.05) between partial-body cryotherapy (9.4 and 6.5%, respectively) and control (7.5 and 5.2%, respectively). These results indicate that the use of partial-body cryotherapy between-training sessions can enhance eccentric muscle performance recovery. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Parasympathetic activity and blood catecholamine responses following a single partial-body cryostimulation and a whole-body cryostimulation.

    Directory of Open Access Journals (Sweden)

    Christophe Hausswirth

    Full Text Available The aim of this study was to compare the effects of a single whole-body cryostimulation (WBC and a partial-body cryostimulation (PBC (i.e., not exposing the head to cold on indices of parasympathetic activity and blood catecholamines. Two groups of 15 participants were assigned either to a 3-min WBC or PBC session, while 10 participants constituted a control group (CON not receiving any cryostimulation. Changes in thermal, physiological and subjective variables were recorded before and during the 20-min after each cryostimulation. According to a qualitative statistical analysis, an almost certain decrease in skin temperature was reported for all body regions immediately after the WBC (mean decrease±90% CL, -13.7±0.7°C and PBC (-8.3±0.3°C, which persisted up to 20-min after the session. The tympanic temperature almost certainly decreased only after the WBC session (-0.32±0.04°C. Systolic and diastolic blood pressures were very likely increased after the WBC session, whereas these changes were trivial in the other groups. In addition, heart rate almost certainly decreased after PBC (-10.9% and WBC (-15.2% sessions, in a likely greater proportion for WBC compared to PBC. Resting vagal-related heart rate variability indices (the root-mean square difference of successive normal R-R intervals, RMSSD, and high frequency band, HF were very likely increased after PBC (RMSSD: +54.4%, HF: +138% and WBC (RMSSD: +85.2%, HF: +632% sessions without any marked difference between groups. Plasma norepinephrine concentrations were likely to very likely increased after PBC (+57.4% and WBC (+76.2%, respectively. Finally, cold and comfort sensations were almost certainly altered after WBC and PBC, sensation of discomfort being likely more pronounced after WBC than PBC. Both acute cryostimulation techniques effectively stimulated the autonomic nervous system (ANS, with a predominance of parasympathetic tone activation. The results of this study also suggest

  12. Whole- and partial-body cryostimulation/cryotherapy: Current technologies and practical applications.

    Science.gov (United States)

    Bouzigon, Romain; Grappe, Frederic; Ravier, Gilles; Dugue, Benoit

    2016-10-01

    Cold therapy is commonly used as a method to relieve pain and inflammation. This review focuses primarily on two methods of cold therapy that have received recent attention: whole-body cryotherapy and partial-body cryotherapy. These methods are used to induce physiological and psychological benefits in humans in the context of medicine, health and sports. The subjects experiencing cryotherapy are dressed in minimal clothing and are exposed to very cold air (at -110°C or less) for 1-4min. Despite the increasing scientific interest in these methods, there is a lack of information about the technologies used. Moreover, there is no existing reference concerning exposure protocols and the relationship between temperature, duration, number of repetitions and the treatments' desired effects. The aim of this review is to compare whole- and partial-body cryotherapy effects (especially on skin temperature) and to classify the protocols for exposure according to the desired effects. This review emphasises 1) the lack of information concerning the actual temperatures inside the cabin or chamber during exposure and 2) the heterogeneity among the exposure protocols that have been reported in the scientific literature. This review will be valuable and relevant to health professionals endeavouring to optimize the cold treatments offered to patients and producers of cryotherapy apparatus striving to create more efficient devices that meet market requirements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Extra source implantation for suppression floating-body effect in partially depleted SOI MOSFETs

    International Nuclear Information System (INIS)

    Chen Jing; Luo Jiexin; Wu Qingqing; Chai Zhan; Huang Xiaolu; Wei Xing; Wang Xi

    2012-01-01

    Silicon-on-insulate (SOI) MOSFETs offer benefits over bulk competitors for fully isolation and smaller junction capacitance. The performance of partially depleted (PD) SOI MOSFETs, though, is not good enough. Since the body is floating, the extra holes (for nMOSFETs) in this region accumulate, causing body potential arise, which of course degrades the performance of the device. How to suppress the floating-body effect becomes critical. There are mainly two ways for the goal. One is to employ body-contact structures, and the other SiGe source/drain structures. However, the former consumes extra area, not welcomed in the state-of-the-art chips design. The latter is not compatible with the traditional CMOS technology. Finding a structure both saving area and compatible technology is the most urgent for PD SOI MOSFETs. Recently, we have developed a new structure with extra heavy boron implantation in the source region for PD SOI nMOSFETs. It consumes no extra area and is also compatible with CMOS technology. The device is found to be free of kink effect in simulation, which implies the floating-body effect is greatly suppressed. In addition, the mechanisms of the kink-free, as well as the impact of different implanting conditions are interpreted.

  14. A Review of Online Partial Discharge Measurement of Large Generators

    Directory of Open Access Journals (Sweden)

    Yuanlin Luo

    2017-10-01

    Full Text Available Online partial discharge (PD measurements have long been used as an effective means to assess the condition of the stator windings of large generators. An increase in the use of PD online measurement systems during the last decade is evident. Improvements in the detection capabilities are partly the reason for the increased popularity. Another reason has been the development of digital signal processing techniques. In addition, rapid progress is being made in automated single PD source classification. However, there are still some factors hindering wider application of the system, such as the complex PD mechanism and PD pulse propagation in stator windings, the presence of detrimental noise and disturbances on-site, and multiple PD sources occurring simultaneously. To avoid repetition of past work and to provide an overview for fresh researchers in this area, this paper presents a comprehensive survey of the state-of-the-art knowledge on PD mechanism, PD pulse propagation in stator windings, PD signal detection methods and signal processing techniques. Areas for further research are also presented.

  15. Biological Dosimetry Using Micronucleus Assay in Simulated Partial-Body Exposure to Ionizing Radiation

    Directory of Open Access Journals (Sweden)

    S. Purnami

    2017-08-01

    Full Text Available In radiation accidents, it is common that only several parts of the body are exposed to radiation. As a consequence there is a mixture of exposed and unexposed lymphocytes in peripheral blood cells of the samples. This phenomenon will cause the dose value estimated using the exposed lymphocytes to be lower than the actual dose. In this study, an assessment of partial body exposures using micronucleus assay by estimating the partial body dose and fraction of irradiated blood was conducted. An optimal D0 value also has been determined in this study to estimate the fraction of irradiated cells. Peripheral blood lymphocytes (PBLs from three healthy donors were irradiated in vitro with 2 Gy of X-rays. Partial radiation exposure was simulated by mixing the irradiated and non-irradiated blood in different proportions. The proportions of mixtures of blood samples irradiated in vitro were 5, 10, 15, 20, and 30 %. Blood samples were then cultured and harvested based on micronuclei assay protocol. At least 2000 binucleated cells with well-preserved cytoplasm were scored for the MN frequency. Dose Estimate 5.1 software was used to calculate the dispersion index (σ2/y and normalized unit of this index (U in each proportion of bloods. The fractions of irradiated cells were calculated with CABAS (Chromosomal Aberration Calculation Software for several different D0 values (2.7; 3.8; 5.4. The results showed that D0 value at 5.4 gave the closest results to the actual proportion of irradiated bloods, while for the dose estimation the estimated doses value from all proportions in all donors were higher than the actual dose. The factor that may cause this phenomenon was that the dose response calibration curve used to predict the radiation dose was not constructed in the laboratory used. Overall it can be concluded that a biodosimetry using MN assay can be used to estimate the radiation dose in partial body exposure. In order to establish a biodosimetry using MN

  16. Whole body measurements in Bavarian school children

    International Nuclear Information System (INIS)

    Schmier, H.; Berg, D.

    1992-12-01

    On behalf of the Bavarian State Ministry for State Development and Environmental Affairs measurements were conducted using the whole body counters at the Institute for Radiation Hygiene (of the Federal Office for Radiation Protection), and the Institute for Radiation Biology (of the GSF Research Centre for Environment and Health). Between September 1988 and July 1990 about 1600 school children from all over Bavaria were investigated for incorporated radiocesium. The aim of these measurements was to evaluate the whole body activity due to regionally differing soil contaminations in Bavaria following the accident in the nuclear power plant in Chernobyl and to assess the effective dose from an intake of radionuclides for the pupils by comparing the results of their WBC measurements with those of reference groups of children which underwent WBC examinations at regular intervals at both institutes since the middle of the year 1986. The results of the WBC measurements of those pupils who had not eaten mushrooms in the days before the measurement are in good agreement with the results of comparative measurements in children living in the regions of Munich and Frankfurt-am-Main. Based on these results an effective dose of 0,2 mSv for the Munich region children and of 0,1 mSv for Nothern Bavarian children can be derived. For children living in the highest contaminated region of Bavaria, i.e. the counties adjacent to the Alps, no comparable reference group results are available, but the amount of incorporated radiocesium is only twice that for pupils in the Munich region. The mean value for the specific activity of radiocesium in South Bavarian school children who consumed mushrooms was found to be twice the value of pupils who did not. This is also true for that group of children whose parents had bought allegedly low contaminated foodstuffs. Other effecs of nutrition habits on the specific whole body activity could not be found. (orig.) [de

  17. Revisiting Biomarkers of Total-Body and Partial-Body Exposure in a Baboon Model of Irradiation.

    Directory of Open Access Journals (Sweden)

    Marco Valente

    Full Text Available In case of a mass casualty radiation event, there is a need to distinguish total-body irradiation (TBI and partial-body irradiation (PBI to concentrate overwhelmed medical resources to the individuals that would develop an acute radiation syndrome (ARS and need hematologic support (i.e., mostly TBI victims. To improve the identification and medical care of TBI versus PBI individuals, reliable biomarkers of exposure could be very useful. To investigate this issue, pairs of baboons (n = 18 were exposed to different situations of TBI and PBI corresponding to an equivalent of either 5 Gy 60Co gamma irradiation (5 Gy TBI; 7.5 Gy left hemibody/2.5 right hemibody TBI; 5.55 Gy 90% PBI; 6.25 Gy 80% PBI; 10 Gy 50% PBI, 15 Gy 30% PBI or 2.5 Gy (2.5 Gy TBI; 5 Gy 50% PBI. More than fifty parameters were evaluated before and after irradiation at several time points up to 200 days. A partial least square discriminant analysis showed a good distinction of TBI from PBI situations that were equivalent to 5 Gy. Furthermore, all the animals were pooled in two groups, TBI (n = 6 and PBI (n = 12, for comparison using a logistic regression and a non parametric statistical test. Nine plasmatic biochemical markers and most of hematological parameters turned out to discriminate between TBI and PBI animals during the prodromal phase and the manifest illness phase. The most significant biomarkers were aspartate aminotransferase, creatine kinase, lactico dehydrogenase, urea, Flt3-ligand, iron, C-reactive protein, absolute neutrophil count and neutrophil-to-lymphocyte ratio for the early period, and Flt3-ligand, iron, platelet count, hemoglobin, monocyte count, absolute neutrophil count and neutrophil-to-lymphocyte ratio for the ARS phase. These results suggest that heterogeneity could be distinguished within a range of 2.5 to 5 Gy TBI.

  18. Supersymmetric many-body systems from partial symmetries — integrability, localization and scrambling

    Energy Technology Data Exchange (ETDEWEB)

    Padmanabhan, Pramod [Fields, Gravity & Strings, CTPU, Institute for Basic Science,Daejeon 34037 (Korea, Republic of); Rey, Soo-Jong [Fields, Gravity & Strings, CTPU, Institute for Basic Science,Daejeon 34037 (Korea, Republic of); School of Physics and Astronomy & Center for Theoretical Physics, Seoul National University,Seoul 06544 (Korea, Republic of); Department of Basic Sciences, University of Science and Technology, Daejeon 34113 (Korea, Republic of); Teixeira, Daniel; Trancanelli, Diego [Institute of Physics, University of São Paulo, 05314-970 São Paulo (Brazil)

    2017-05-25

    Partial symmetries are described by generalized group structures known as symmetric inverse semigroups. We use the algebras arising from these structures to realize supersymmetry in (0+1) dimensions and to build many-body quantum systems on a chain. This construction consists in associating appropriate supercharges to chain sites, in analogy to what is done in spin chains. For simple enough choices of supercharges, we show that the resulting states have a finite non-zero Witten index, which is invariant under perturbations, therefore defining supersymmetric phases of matter protected by the index. The Hamiltonians we obtain are integrable and display a spectrum containing both product and entangled states. By introducing disorder and studying the out-of-time-ordered correlators (OTOC), we find that these systems are in the many-body localized phase and do not thermalize. Finally, we reformulate a theorem relating the growth of the second Rényi entropy to the OTOC on a thermal state in terms of partial symmetries.

  19. Rocket measurement of auroral partial parallel distribution functions

    Science.gov (United States)

    Lin, C.-A.

    1980-01-01

    The auroral partial parallel distribution functions are obtained by using the observed energy spectra of electrons. The experiment package was launched by a Nike-Tomahawk rocket from Poker Flat, Alaska over a bright auroral band and covered an altitude range of up to 180 km. Calculated partial distribution functions are presented with emphasis on their slopes. The implications of the slopes are discussed. It should be pointed out that the slope of the partial parallel distribution function obtained from one energy spectra will be changed by superposing another energy spectra on it.

  20. Estimating Body Weight of Cattle Using Linear Body Measurements ...

    African Journals Online (AJOL)

    The relationships between body weight (BW) and heart girth, body length and height at withers of 116 Indigenous, 72 Friesian, 95 Brahman, 88 Red Dane and 123 Crossbred cattle from 42 smallholder herds in Nharira-Lancashire, Zimbabwe, were investigated. The principal objective was to develop simple models that ...

  1. Estimation of Body Weight from Body Size Measurements and Body Condition Scores in Dairy Cows

    DEFF Research Database (Denmark)

    Enevoldsen, Carsten; Kristensen, T.

    1997-01-01

    , and body condition score were consistently associated with BW. The coefficients of multiple determination varied from 80 to 89%. The number of significant terms and the parameter estimates of the models differed markedly among groups of cows. Apparently, these differences were due to breed and feeding...... regimen. Results from this study indicate that a reliable model for estimating BW of very different dairy cows maintained in a wide range of environments can be developed using body condition score, demographic information, and measurements of hip height and hip width. However, for management purposes......The objective of this study was to evaluate the use of hip height and width, body condition score, and relevant demographic information to predict body weight (BW) of dairy cows. Seven regression models were developed from data from 972 observations of 554 cows. Parity, hip height, hip width...

  2. Dose-response relationships for chromosome aberrations in peripheral blood lymphocytes after whole- and partial-body irradiations. Pt. 1

    International Nuclear Information System (INIS)

    Liniecki, J.; Bajerska, A.; Wyszynska, K.

    1983-01-01

    Dose-response relationships were established for yield of dicentrics and for a fraction of damaged metaphases in lymphocytes after γ-irradiation of rabbits' whole blood in vitro. These relationships were based on the scoring of cells only in their first post-stimulation division and they served as a reference system for comparison with results of 60 Co γ-irradiation in vivo, either of the whole or of predetermined parts of an animal's body. There was a statistically acceptable agreement between dose-response data established for dicentric yield after whole-body irradiation in vivo and the reference dose-response curve derived from exposure of rabbit's blood in vitro. For partial-body (1/2) irradiations there was a satisfactory agreement between the dose-response curves in vitro for dicentric yield and fraction of metaphases damaged on the one hand and the response in vivo when the latter was related to mean doses to circulating blood. However, there was a drastic disagreement with the dose responses in vitro when measured cytogenetic quantities were plotted versus mean doses to body mass. When the latter were substituted for by comparable doses to circulating blood the in vivo-in vitro agreement was acceptable after irradiation. (orig.)

  3. Some long-term effects of negative pions in mice exposed to partial body irradiation

    International Nuclear Information System (INIS)

    Coggle, J.E.

    1977-01-01

    The long-term effects of partial body exposure of one-day-old mice given either 60 Co γ rays or negative pions have been studied. Both radiations produced considerable life-shortening; for pions 6.8 +- 1.5% of life was lost per 100 rad and for γ rays the value was 5.7 +- 0.5% per 100 rad. The RBE of pions for ten weeks of life-shortening was about 1.3 compared with 60 Co γ rays, although at lower doses the RBE may be higher reaching about two for six weeks of life-shortening. The incidence rate of tumours at any particular age was greater in mice irradiated with pions at the peak and in those given higher doses of γ rays than in the controls. (author)

  4. Acute Effects of Partial-Body Cryotherapy on Isometric Strength: Maximum Handgrip Strength Evaluation.

    Science.gov (United States)

    De Nardi, Massimo; Pizzigalli, Luisa; Benis, Roberto; Caffaro, Federica; Micheletti Cremasco, Margherita

    2017-12-01

    De Nardi, M, Pizzigalli, L, Benis, R, Caffaro, F, and Cremasco, MM. Acute effects of partial-body cryotherapy on isometric strength: maximum handgrip strength evaluation. J Strength Cond Res 31(12): 3497-3502, 2017-The aim of the study was to evaluate the influence of a single partial-body cryotherapy (PBC) session on the maximum handgrip strength (JAMAR Hydraulic Hand dynamometer). Two hundred healthy adults were randomized into a PBC group and a control group (50 men and 50 women in each group). After the initial handgrip strength test (T0), the experimental group performed a 150-second session of PBC (temperature range between -130 and -160° C), whereas the control group stayed in a thermo neutral room (22.0 ± 0.5° C). Immediately after, both groups performed another handgrip strength test (T1). Data underlined that both groups showed an increase in handgrip strength values, especially the experimental group (Control: T0 = 39.48 kg, T1 = 40.01 kg; PBC: T0 = 39.61 kg, T1 = 41.34 kg). The analysis also reported a statistical effect related to gender (F = 491.99, P ≤ 0.05), with women showing lower handgrip strength values compared with men (women = 30.43 kg, men = 52.27 kg). Findings provide the first evidence that a single session of PBC leads to the improvement of muscle strength in healthy people. The results of the study imply that PBC could be performed also before a training session or a sport competition, to increase hand isometric strength.

  5. Elucidating mechanisms for insect body size: partial support for the oxygen-dependent induction of moulting hypothesis.

    Science.gov (United States)

    Kivelä, Sami M; Viinamäki, Sonja; Keret, Netta; Gotthard, Karl; Hohtola, Esa; Välimäki, Panu

    2018-01-25

    Body size is a key life history trait, and knowledge of its mechanistic basis is crucial in life history biology. Such knowledge is accumulating for holometabolous insects, whose growth is characterised and body size affected by moulting. According to the oxygen-dependent induction of moulting (ODIM) hypothesis, moult is induced at a critical mass at which oxygen demand of growing tissues overrides the supply from the tracheal respiratory system, which principally grows only at moults. Support for the ODIM hypothesis is controversial, partly because of a lack of proper data to explicitly test the hypothesis. The ODIM hypothesis predicts that the critical mass is positively correlated with oxygen partial pressure ( P O 2 ) and negatively with temperature. To resolve the controversy that surrounds the ODIM hypothesis, we rigorously test these predictions by exposing penultimate-instar Orthosia gothica (Lepidoptera: Noctuidae) larvae to temperature and moderate P O 2  manipulations in a factorial experiment. The relative mass increment in the focal instar increased along with increasing P O 2 , as predicted, but there was only weak suggestive evidence of the temperature effect. Probably owing to a high measurement error in the trait, the effect of P O 2  on the critical mass was sex specific; high P O 2  had a positive effect only in females, whereas low P O 2  had a negative effect only in males. Critical mass was independent of temperature. Support for the ODIM hypothesis is partial because of only suggestive evidence of a temperature effect on moulting, but the role of oxygen in moult induction seems unambiguous. The ODIM mechanism thus seems worth considering in body size analyses. © 2018. Published by The Company of Biologists Ltd.

  6. High-resolution gamma spectroscopy with whole-body and partial-body counters. Experience, recommendations. Report; Hochaufloesende Gamma-Spektrometrie an Ganz- und Teilkoerperzaehlern. Erfahrungen, Empfehlungen. Bericht

    Energy Technology Data Exchange (ETDEWEB)

    Sahre, P. [comp.

    1997-12-01

    The application of high-resolution gamma spectroscopy with whole-body and partial-body counters shows a steadily rising upward trend over the last few years. This induced the ``Arbeitskreis Inkorporationsueberwachung`` of the association ``Fachverband fuer Strahlenschutz e.V.`` to organise a meeting for joint elaboration of a guide on recommended applications of this measuring technique, based on a review of existing experience and results. A key item on the agenda of the meeting was the comparative evaluation of the Ge semiconductor detector and the NaI solid scintillation detector. (orig./CB) [Deutsch] Der Einsatz der hochaufloesenden Gammaspektroskopie in Ganz- und Teilkoerperzaehlern hat in den letzten Jahren stetig zugenommen. Der ``Arbeitskreis Inkorporationsueberwachung`` des Fachverbandes fuer Strahlenschutz e.V. hat darum bisherige Erfahrungen zusammengetragen und Empfehlungen fuer den Einsatz dieser Messtechnik erarbeitet. Der Schwerpunkt der Tagung lag beim Vergleich von Germaniumhalbleiter- mit Natriumjodid-Festszintillationsdetektoren.Tl-Detektoren eignen sich v.a. beim Vorhandensein bekannter und zeitlich konstanter Nuklidvektoren (Kernkraftwerke, Nuklearmedizin). Bei unbekanntem bzw. variablem Nuklidvektor (Stoerfall, Unfall, Forschung) sollen Ge-Detektoren benutzt werden (orig./ABI)

  7. Generic calculation of two-body partial decay widths at the full one-loop level

    Science.gov (United States)

    Goodsell, Mark D.; Liebler, Stefan; Staub, Florian

    2017-11-01

    We describe a fully generic implementation of two-body partial decay widths at the full one-loop level in the SARAH and SPheno framework compatible with most supported models. It incorporates fermionic decays to a fermion and a scalar or a gauge boson as well as scalar decays into two fermions, two gauge bosons, two scalars or a scalar and a gauge boson. We present the relevant generic expressions for virtual and real corrections. Whereas wave-function corrections are determined from on-shell conditions, the parameters of the underlying model are by default renormalised in a \\overline{ {DR}} (or \\overline{ {MS}}) scheme. However, the user can also define model-specific counter-terms. As an example we discuss the renormalisation of the electric charge in the Thomson limit for top-quark decays in the standard model. One-loop-induced decays are also supported. The framework additionally allows the addition of mass and mixing corrections induced at higher orders for the involved external states. We explain our procedure to cancel infrared divergences for such cases, which is achieved through an infrared counter-term taking into account corrected Goldstone boson vertices. We compare our results for sfermion, gluino and Higgs decays in the minimal supersymmetric standard model (MSSM) against the public codes SFOLD, FVSFOLD and HFOLD and explain observed differences. Radiatively induced gluino and neutralino decays are compared against the original implementation in SPheno in the MSSM. We exactly reproduce the results of the code CNNDecays for decays of neutralinos and charginos in R-parity violating models. The new version SARAH 4.11.0 by default includes the calculation of two-body decay widths at the full one-loop level. Current limitations for certain model classes are described.

  8. Generic calculation of two-body partial decay widths at the full one-loop level

    Energy Technology Data Exchange (ETDEWEB)

    Goodsell, Mark D. [UPMC Univ. Paris 06 (France); Centre National de la Recherche Scientifique (CNRS), 75 - Paris (France); Sorbonne Univ., Paris (France); Liebler, Stefan [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Staub, Florian [Karlsruhe Institute for Technology, Karlsruhe (Germany). Inst. for Theoretical Physics; Karlsruhe Institute for Technology, Eggenstein-Leopoldshafen (Germany). Inst. for Nuclear Physics

    2017-04-15

    We describe a fully generic implementation of two-body partial decay widths at the full one-loop level in the SARAH and SPheno framework compatible with most supported models. It incorporates fermionic decays to a fermion and a scalar or a gauge boson as well as scalar decays into two fermions, two gauge bosons, two scalars or a scalar and a gauge boson. We present the relevant generic expressions for virtual and real corrections. Whereas wavefunction corrections are determined from on-shell conditions, the parameters of the underlying model are by default renormalised in a DR (or MS) scheme. However, the user can also define model-specific counter-terms. As an example we discuss the renormalisation of the electric charge in the Thomson limit for top-quark decays in the standard model. One-loop induced decays are also supported. The framework additionally allows the addition of mass and mixing corrections induced at higher orders for the involved external states. We explain our procedure to cancel infra-red divergences for such cases, which is achieved through an infra-red counter-term taking into account corrected Goldstone boson vertices. We compare our results for sfermion, gluino and Higgs decays in the minimal supersymmetric standard model (MSSM) against the public codes SFOLD, FVSFOLD and HFOLD and explain observed differences. Radiative induced gluino and neutralino decays are compared against the original implementation in SPheno in the MSSM. We exactly reproduce the results of the code CNNDecays for decays of neutralinos and charginos in R-parity violating models. The new version SARAH 4.11.0 by default includes the calculation of two-body decay widths at the full one-loop level. Current limitations for certain model classes are described.

  9. Generic calculation of two-body partial decay widths at the full one-loop level

    Energy Technology Data Exchange (ETDEWEB)

    Goodsell, Mark D. [Sorbonne Universites, UPMC Univ Paris 06, UMR 7589, LPTHE, Paris (France); CNRS, UMR 7589, LPTHE, Paris (France); Liebler, Stefan [DESY, Hamburg (Germany); Staub, Florian [Karlsruhe Institute of Technology, Institute for Theoretical Physics (ITP), Karlsruhe (Germany); Karlsruhe Institute of Technology, Institute for Nuclear Physics (IKP), Eggenstein-Leopoldshafen (Germany)

    2017-11-15

    We describe a fully generic implementation of two-body partial decay widths at the full one-loop level in the SARAH and SPheno framework compatible with most supported models. It incorporates fermionic decays to a fermion and a scalar or a gauge boson as well as scalar decays into two fermions, two gauge bosons, two scalars or a scalar and a gauge boson. We present the relevant generic expressions for virtual and real corrections. Whereas wave-function corrections are determined from on-shell conditions, the parameters of the underlying model are by default renormalised in a DR (or MS) scheme. However, the user can also define model-specific counter-terms. As an example we discuss the renormalisation of the electric charge in the Thomson limit for top-quark decays in the standard model. One-loop-induced decays are also supported. The framework additionally allows the addition of mass and mixing corrections induced at higher orders for the involved external states. We explain our procedure to cancel infrared divergences for such cases, which is achieved through an infrared counter-term taking into account corrected Goldstone boson vertices. We compare our results for sfermion, gluino and Higgs decays in the minimal supersymmetric standard model (MSSM) against the public codes SFOLD, FVSFOLD and HFOLD and explain observed differences. Radiatively induced gluino and neutralino decays are compared against the original implementation in SPheno in the MSSM. We exactly reproduce the results of the code CNNDecays for decays of neutralinos and charginos in R-parity violating models. The new version SARAH 4.11.0 by default includes the calculation of two-body decay widths at the full one-loop level. Current limitations for certain model classes are described. (orig.)

  10. Generic calculation of two-body partial decay widths at the full one-loop level

    International Nuclear Information System (INIS)

    Goodsell, Mark D.; Liebler, Stefan; Staub, Florian; Karlsruhe Institute for Technology, Eggenstein-Leopoldshafen

    2017-04-01

    We describe a fully generic implementation of two-body partial decay widths at the full one-loop level in the SARAH and SPheno framework compatible with most supported models. It incorporates fermionic decays to a fermion and a scalar or a gauge boson as well as scalar decays into two fermions, two gauge bosons, two scalars or a scalar and a gauge boson. We present the relevant generic expressions for virtual and real corrections. Whereas wavefunction corrections are determined from on-shell conditions, the parameters of the underlying model are by default renormalised in a DR (or MS) scheme. However, the user can also define model-specific counter-terms. As an example we discuss the renormalisation of the electric charge in the Thomson limit for top-quark decays in the standard model. One-loop induced decays are also supported. The framework additionally allows the addition of mass and mixing corrections induced at higher orders for the involved external states. We explain our procedure to cancel infra-red divergences for such cases, which is achieved through an infra-red counter-term taking into account corrected Goldstone boson vertices. We compare our results for sfermion, gluino and Higgs decays in the minimal supersymmetric standard model (MSSM) against the public codes SFOLD, FVSFOLD and HFOLD and explain observed differences. Radiative induced gluino and neutralino decays are compared against the original implementation in SPheno in the MSSM. We exactly reproduce the results of the code CNNDecays for decays of neutralinos and charginos in R-parity violating models. The new version SARAH 4.11.0 by default includes the calculation of two-body decay widths at the full one-loop level. Current limitations for certain model classes are described.

  11. Treadmill training with partial body weight support after stroke: a review.

    Science.gov (United States)

    Hesse, Stefan

    2008-01-01

    Restoration and improvement of gait after stroke are major aspects of neurorehabilitation. Mobilization out of the bed into the wheelchair and verticalisation with the help of a standing frame are first steps. With the patient cardiovascular stable, gait restoration is put on the agenda. Instead of tone-inhibiting and gait preparatory maneuvers, patients should practice complex gait cycles repetitively. Treadmill training with partial body weight support enables the harness-secured patients to practice numerous steps assisted by two or three therapists. In controlled studies, it proved equally effective as walking on the floor. Gait machines, as the Lokomat or the Gait Trainer GTI, intend to relieve the strenuous effort for the therapists. For the GTI, several controlled trials showed a superior effect in acute stroke patients with respect to walking ability and velocity. For the ambulatory patient, aerobic treadmill training is effective to improve speed and endurance without worsening gait quality. Belt velocity and inclination are gradually increased so that the patients reach a predefined target heart rate. On the belt, patients walk more symmetrically, and higher velocities result in a facilitation of paretic muscles and render gait more efficient. In summary, gait rehabilitation has seen dramatic changes over the last years. More is to be expected.

  12. Body weight prediction of Brakmas and Bali cattle using body measurements

    Directory of Open Access Journals (Sweden)

    Mohd. Hafiz, A.W.

    2016-06-01

    Full Text Available In the rural areas facilities for farm animal weighing are often difficult to find and the construction of such facilities is relatively expensive. Therefore a study was conducted with the objective to estimate body weight of Brakmas and Bali cattle using prediction equations of linear body measurements. Data of body weight and body measurements, namely withers height, body length and heart girth from 279 heads of Brakmas (age 1 to 10 y old and 74 heads of Bali (age 1 to 10 y old cows were collected. The animals were in average body condition of 3 (1= emaciated, 3= moderate fat cover, and 5= excess fat cover. The correlation analysis showed that body weight of Brakmas cattle was highly correlated with its body length, heart girth and withers height with the correlation coefficients of 0.967, 0.964 and 0.942, respectively, while body weight in Bali cattle had the highest correlation with heart girth followed by body length and height at withers with the correlation coefficient of 0.985, 0.954 and 0.945, respectively. Regression analysis showed that body length provided a good estimate of live body weight with high precision as it accounted for 91.6% of the variability in body weight in Brakmas cattle, while heart girth accounted 97.1% of body weight variability in Bali cattle. The combination of body length-withers height, body length-heart girth and body length-withers height-heart girth showed an improvement in terms of predictive precision with the changes of 0.21%, 0.21% and 0.44%, respectively, in coeficient of determination (R2 compared to a single measure of body length in Brakmas cattle. The combination of heart girth-body length did not show any change in R2 in Bali cattle compared to a single measure of heart girth. Combining heart girth-height at withers and the combination of all body measurements showed the increment in coefficients of determination at 0.41% and 0.51%, respectively as compared to heart girth. Although the combination

  13. Testing measurement invariance of composites using partial least squares

    NARCIS (Netherlands)

    Henseler, Jörg; Ringle, Christian M.; Sarstedt, Marko

    2016-01-01

    Purpose Research on international marketing usually involves comparing different groups of respondents. When using structural equation modeling (SEM), group comparisons can be misleading unless researchers establish the invariance of their measures. While methods have been proposed to analyze

  14. Mars Atmospheric Entry Integrated Navigation with Partial Intermittent Measurements

    Directory of Open Access Journals (Sweden)

    Tai-shan Lou

    2017-01-01

    Full Text Available Signal degradation suffered by the vehicle is a combination brownout and blackout during Mars atmospheric entry. The communications brownout means that signal fades and blackout means that the signal is lost completely. The communications brownout and blackout periods are analyzed and predicted with an altitude and velocity profiles. In the brownout period, the range measurements between the vehicle and the orbiters are modeled as intermittent measurements with the radio signal arrival probabilities, which are distributed as a Rayleigh distribution of the electron number density around the entry vehicle. A new integrated navigation strategy during the Mars atmospheric entry phase is proposed to consider the probabilities of the radio measurements in the communications brownout and blackout periods under the IMU/beacon scenario based on the information filter with intermittent measurements. Numerical navigation simulations are designed to show the performance of the proposed navigation strategy under the integrated navigation scenario.

  15. Gigi tiruan sebagian lepasan sebagai benda asing dalam trakea (Removable partial denture as foreign body in trachea

    Directory of Open Access Journals (Sweden)

    Sri Herawati JPB

    2005-09-01

    Full Text Available Foreign bodies in the trachea are not uncommon. Usually the patients come with dyspnea and a history of having aspirate something. This is an emergency case and needs extraction of the foreign body via bronchoscopy with general anesthesia as soon as possible. The optimal preparation is a controlled, well-equipped and well prepared operative setting. A case of removable partial denture as foreign body in trachea was reported and the extraction of the denture was done with difficulty due to the size of the denture compared with the width of the rima glottis and the trachea.

  16. Determining nonsmooth first order terms from partial boundary measurements

    DEFF Research Database (Denmark)

    Knudsen, Kim; Salo, Mikko

    2007-01-01

    We extend results of Dos Santos Ferreira-Kenig-Sjöstrand-Uhlmann(arXiv:math.AP/0601466) to less smooth coefficients, and we show that measurements on part of the boundary for the magnetic Schrödinger operator determine uniquely the magnetic field related to a H¨older continuous potential. We give...

  17. Measurement of total body radioactivity in man

    International Nuclear Information System (INIS)

    Naversten, Y.

    1982-01-01

    Techniques for the determination of whole-body radioactivity in man using uncollimated NaI(Tl) detectors have been studied. Geometrical effects and photon attenuation effects due to the different shapes of humans as well as due to varying in-vivo radioactivity distributions have been evaluated particularly for scanning-bed geometries and the chair geometry. Theoretically it is shown that the attenuation effects are generally dominating, for full-energy-peak pulse-range methods. For the application in radiation protection a cheap and simple chair-geometry unit has been constructed and used at various places distantly from the home-laboratory, for studies of body activity of Cs-137 in northern Sweden. High body activities were found particularly in reindeer-breeding Lapps. The elimination rate of Cs-137 in man was studied in the stationary whole-body counter in Lund as well as with the field-system. For the study of the performances at low and high photon energies clinical applications of methods for gastro-intestinal absorption of vitamin B12 (Co-57; 122 keV) and total body potassium determination (K-40; 1.46 MeV, K-42; 1.52 MeV) have been evaluated. Theoretical and experimental results as well as experiences of applications in radiation protection and medicine show that the scanning-bed geometry effectively evens out redistributional effects. For optimum results, however, scatter-energy pulse-ranges rather than full-energy-peak ranges should be used. (Auth.)

  18. Quantitative whole-body MRI in familial partial lipodystrophy type 2: changes in adipose tissue distribution coincide with biochemical improvement.

    LENUS (Irish Health Repository)

    McLaughlin, Patrick D

    2012-11-01

    OBJECTIVE: Familial partial lipodystrophy type 2 (Online Mendelian Inheritance in Man no. 151660) is a systemic disorder characterized by regional lipoatrophy and lipohypertrophy, severe insulin resistance, and early cardiovascular death. At initial presentation, whole-body MRI allows the radiologist to accurately characterize patients with familial partial lipodystrophy and helps differentiate familial partial lipodystrophy from many other subtypes of lipodystophy. We present the findings of serial quantitative MRI analysis in two patients with familial partial lipodystrophy type 2 and outline the objective imaging changes that occur during medical therapy with oral rosiglitazone. CONCLUSION: Cervical adipose volume and visceral adipose area increased by 105% and 60% in the two patients and hepatic fat fraction decreased by 55% during a 21-month period of medical therapy. These changes coincided with a decrease in biochemical indexes of insulin resistance. Whole body quantitative MRI may therefore help to demonstrate the subclinical changes in fat deposition that occur as a result of novel treatment of familial partial lipodystrophy and with continued research may play a role in guiding the choice, duration, and intensity of novel medical therapy.

  19. Live weight and body measurement of Hungarian Thoroughbred broodmares

    Directory of Open Access Journals (Sweden)

    Szabolcs Bene

    2013-09-01

    Full Text Available Live weights and 21 body measurements of 110 adult brood mares from Thoroughbred breed were evaluated in Hungary. Body measurements and some body measure indices were determined. One way ANOVA was used to compare the studs. Regression equations were developed to estimate the live weight from body measurements. Population genetic parameters of the examined traits were estimated. Only few differences among studs, concerning evaluated body measurements, were presented - firstly: body measurements, related to the kilter and nutritional status (hearth girth - were significant. Between the mentioned traits and the live weight medium positive correlation (r = 0.47 - 0.79; P<0.01 was found. For the estimation of live weight with regression model the necessary data are as follows: hearth girth, 2nd width of rump and diagonal length of body. The determination coefficient was 0.80 (P<0.01. Height at withers, of back and at rump (h2 = 0.66, 0.67 and 0.51 showed medium heritability values. The heritability of depth of chest and height of bieler-point were 0.32 and 0.48, respectively. Quite small differences were found between the stallions in most of the body measurements. The live weight and height measurements were exceptions, as here the differences between the sires were slightly higher. As a conclusion it can be stated that the Thoroughbred population in Hungary is quite homogenous in terms of the most important body measurements.

  20. Dynamic Anthropometry – Deffning Protocols for Automatic Body Measurement

    Directory of Open Access Journals (Sweden)

    Slavenka Petrak

    2017-12-01

    Full Text Available The paper presents the research on possibilities of protocol development for automatic computer-based determination of measurements on a 3D body model in defined dynamic positions. Initially, two dynamic body positions were defined for the research on dimensional changes of targeted body lengths and surface segments during body movement from basic static position into a selected dynamic body position. The assumption was that during body movement, specifi c length and surface dimensions would change significantly from the aspect of clothing construction and functionality of a garment model. 3D body scanning of a female test sample was performed in basic static and two defined dynamic positions. 3D body models were processed and measurement points were defined as a starting point for the determination of characteristic body measurements. The protocol for automatic computer measurement was defined for every dynamic body position by the systematic set of activities based on determined measurement points. The verification of developed protocols was performed by automatic determination of defined measurements on the test sample and by comparing the results with the conventional manual measurement.

  1. Estimation of Live Weight of Calves from Body Measurements within ...

    African Journals Online (AJOL)

    All phenotypic correlations between body measurements were positive and significant (P<0.001). The highest correlation coefficient was found between chest girth and body weight. The polynomial equation using chest girth as an independent variable predicted body weight more accurately within breed as compared to the ...

  2. Solving of some Problems with On-Line Mode Measurement of Partial Discharges

    Directory of Open Access Journals (Sweden)

    Karel Zalis

    2004-01-01

    Full Text Available This paper deals with the problems discussing the transition from off-line diagnostic methods to on-line ones. Based on the experience with commercial partial discharge measuring equipment a new digital system for the evaluation of partial discharge measurement including software and hardware facilities has been developed at the Czech Technical University in Prague. Two expert systems work in this complex evaluating system: a rule-based expert system performing an amplitude analysis of partial discharge impulses for determining the damage of the insulation system, and a neural network which is used for a phase analysis of partial discharge impulses to determine the kind of partial discharge activity. Problem of the elimination of disturbances is also discussed.

  3. γ-ray induced chromosome aberration in rabbit peripheral blood lymphocytes irradiated in partial and whole body and decline of aberration rate with time post-exposure

    International Nuclear Information System (INIS)

    Zhang Lianzhen; Deng Zhicheng; Wang Haiyan

    1997-01-01

    Te author presents the results of study on 60 Co γ-ray induced chromosome aberration in rabbits peripheral blood lymphocytes irradiated in partial and whole body and the aberration rate decrease with the time of post-exposure. The experiments included 5 groups, it was whole-body exposure group, partial-body exposure (abdomen and pelvic cavity) group, blood irradiation group in vitro and control group respectively. Radiation dose was 3.0 Gy delivered at rate of 0.5 Gy/min. The results show that it was no significant differences between whole body and in blood irradiation group. The chromosome aberration yield in whole body exposure group was higher than that in partial-body group and in the abdomen exposure group was higher than in that in the pelvic cavity irradiation; The chromosome aberration rate decreased with the time of post-exposure in partial and whole body by γ-ray irradiation

  4. Field measurements of radium in the human body

    International Nuclear Information System (INIS)

    Toohey, R.E.; May, H.A.

    1978-01-01

    Two whole body counting systems have been developed and employed for field measurements. The radium contents of nine previously unmeasured cases have been determined during three field trips. Future trips are being scheduled to make body radioactivity measurements on a specific subpopulation of CHR radium cases

  5. Establishment of Average Body Measurement and the Development ...

    African Journals Online (AJOL)

    cce

    body measurement for height and backneck to waist for ages 2,3,4 and 5 years. The ... average measurements of the different parts of the body must be established. ..... and OAU Charter on Rights of the child: Lagos: Nigeria Country office.

  6. Measurement of Organ Uptake by Whole-Body Counting

    International Nuclear Information System (INIS)

    Dudley, R.A.

    1970-01-01

    This paper reviews methods for the measurement of radioactivity in body organs based on whole-body radioactivity measurements. Such measurements can of course only be used to measure radioactivity in a body organ when the radioactivity is exclusively localized in the organ or when the ratio of radioactivity in the organ to that in the whole body is known from other sources of information. They find particular applications, however, when the organ is so widely dispersed throughout the body that more localized measurement is impossible. Examples of situations in which whole-body radioactivity measurements have been used in this way are cited. The more important techniques used for such measurements are described and their respective advantages and disadvantages indicated. The importance of uniformity of counting efficiency with position of source throughout the body is stressed. Simple systems incorporating sodium iodide crystal scintillation detectors are shown to combine satisfactory sensitivity and uniformity of efficiency for clinical measurements of radioactivity in body organs and have the additional advantage that they can be readily adapted for profile scanning. Systems incorporating plastic or liquid scintillation detectors are less convenient in this respect. (author)

  7. Measurement of body potassium with a whole-body counter: relationship between lean body mass and resting energy expenditure

    International Nuclear Information System (INIS)

    Jensen, M.D.; Braun, J.S.; Vetter, R.J.; Marsh, H.M.

    1988-01-01

    We conducted studies to determine whether the Mayo whole-body counter could be used to measure body potassium, and thus lean body mass (LBM), and whether moderate obesity alters resting energy expenditure when corrected for LBM. Twenty-four nonobese and 18 moderately obese adults underwent body potassium (40K) counting, as well as tritiated water space measurement and indirect calorimetry. LBM values predicted from 40K counting and tritiated water space measurements were highly correlated (P = 0.001; r = 0.88). Resting energy expenditure was closely related to LBM (P less than 0.0001; r = 0.78): kcal/day = 622 kcal + (LBM.20.0 kcal/kg LBM). In this relationship, the obese subjects did not differ from nonobese subjects. In summary, the Mayo whole-body counter can accurately measure LBM, and moderate obesity has no detectable effect on corrected resting energy expenditure

  8. Aminophylline partially prevents the decrease of body temperature during laparoscopic abdominal surgery.

    Science.gov (United States)

    Kim, Dae Woo; Lee, Jung Ah; Jung, Hong Soo; Joo, Jin Deok; In, Jang Hyeok; Jeon, Yeon Soo; Chun, Ga Young; Choi, Jin Woo

    2014-08-01

    Aminophylline can elicit thermogenesis in rats or increase metabolic rate during cold stress in lambs. We tested the hypothesis that aminophylline would reduce the change in core body temperature during laparoscopic abdominal surgery requiring pneumoperitoneum. Fifty patients were randomly divided into an aminophylline group (n=25) and a saline control group (n=25). Esophageal temperature, index finger temperature, and hemodynamic variables, such as mean blood pressure and heart rate, were measured every 15 min during sevoflurane anesthesia. In the aminophylline group, esophageal temperatures at T45 (36.1±0.38 vs. 35.7±0.29, P=0.024), T60 (36.0±0.39 vs. 35.6±0.28, P=0.053), T75 (35.9±0.34 vs. 35.5±0.28, P=0.025), T90 (35.8±0.35 vs. 35.3±0.33, P=0.011), and T105 (35.8±0.36 vs. 35.1±0.53, P=0.017) and index finger temperatures at T15 (35.8±0.46 vs. 34.9±0.33, Ptemperature through a thermogenic effect, despite reduced peripheral thermoregulatory vasoconstriction.

  9. Body Temperature Measurements for Metabolic Phenotyping in Mice

    Science.gov (United States)

    Meyer, Carola W.; Ootsuka, Youichirou; Romanovsky, Andrej A.

    2017-01-01

    Endothermic organisms rely on tightly balanced energy budgets to maintain a regulated body temperature and body mass. Metabolic phenotyping of mice, therefore, often includes the recording of body temperature. Thermometry in mice is conducted at various sites, using various devices and measurement practices, ranging from single-time probing to continuous temperature imaging. Whilst there is broad agreement that body temperature data is of value, procedural considerations of body temperature measurements in the context of metabolic phenotyping are missing. Here, we provide an overview of the various methods currently available for gathering body temperature data from mice. We explore the scope and limitations of thermometry in mice, with the hope of assisting researchers in the selection of appropriate approaches, and conditions, for comprehensive mouse phenotypic analyses. PMID:28824441

  10. Estimating body weight and body composition of chickens by using noninvasive measurements.

    Science.gov (United States)

    Latshaw, J D; Bishop, B L

    2001-07-01

    The major objective of this research was to develop equations to estimate BW and body composition using measurements taken with inexpensive instruments. We used five groups of chickens that were created with different genetic stocks and feeding programs. Four of the five groups were from broiler genetic stock, and one was from sex-linked heavy layers. The goal was to sample six males from each group when the group weight was 1.20, 1.75, and 2.30 kg. Each male was weighed and measured for back length, pelvis width, circumference, breast width, keel length, and abdominal skinfold thickness. A cloth tape measure, calipers, and skinfold calipers were used for measurement. Chickens were scanned for total body electrical conductivity (TOBEC) before being euthanized and frozen. Six females were selected at weights similar to those for males and were measured in the same way. Each whole chicken was ground, and a portion of ground material of each was used to measure water, fat, ash, and energy content. Multiple linear regression was used to estimate BW from body measurements. The best single measurement was pelvis width, with an R2 = 0.67. Inclusion of three body measurements in an equation resulted in R2 = 0.78 and the following equation: BW (g) = -930.0 + 68.5 (breast, cm) + 48.5 (circumference, cm) + 62.8 (pelvis, cm). The best single measurement to estimate body fat was abdominal skinfold thickness, expressed as a natural logarithm. Inclusion of weight and skinfold thickness resulted in R2 = 0.63 for body fat according to the following equation: fat (%) = 24.83 + 6.75 (skinfold, ln cm) - 3.87 (wt, kg). Inclusion of the result of TOBEC and the effect of sex improved the R2 to 0.78 for body fat. Regression analysis was used to develop additional equations, based on fat, to estimate water and energy contents of the body. The body water content (%) = 72.1 - 0.60 (body fat, %), and body energy (kcal/g) = 1.097 + 0.080 (body fat, %). The results of the present study

  11. Oscillation measuring device for body of rotation

    International Nuclear Information System (INIS)

    Komita, Hideo.

    1994-01-01

    The present invention concerns an internal pump of a BWR type reactor and provides a device for detecting oscillations of a rotational shaft. Namely, recesses are formed along an identical circumference on the outer circumferential surface of the rotating portion each at a predetermined distance. The recesses rotate along with the rotation. An eddy current type displacement gage measures the distance to the outer circumferential surface of the rotating portion. The recesses are detected by the displacement gage as pulse signals. When the rotating portion oscillates, it is detected by the displacement gage as waveform signals. Accordingly, the output signals of the eddy current type displacement gage are formed by pulse signals superposed on the waveform signals. A rising detection circuit detects the rising position of the pulse signals as the components of the number of rotation of the rotating portion, and fall detection circuit detects the falling position. A comparator circuit is disposed in parallel with both of rising/falling detection circuits. A predetermined threshold value is set in the comparator circuit to output a signal when the inputted signal exceeds the value. (I.S.)

  12. Principal Component Analysis of Body Measurements In Three ...

    African Journals Online (AJOL)

    This study was conducted to explore the relationship among body measurements in 3 strains of broilers chicken (Arbor Acre, Marshal and Ross) using principal component analysis with the view of identifying those components that define body conformation in broilers. A total of 180 birds were used, 60 per strain.

  13. Improved measurement system for the whole body monitor

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1983-01-01

    A static four-detector system has been established as a whole body radioactivity measurement system. A technique is being developed to position the detectors in such a manner as to minimise longitudinal distribution effects within a subject. This technique, which represents the human body as a simple geometric model, requires the determination of efficiency at any point within this model

  14. Relationship between pelvic and linear body measurements in ...

    African Journals Online (AJOL)

    The aim of this study was to determine pelvic height, width and area and to estimate correlations between these measurements and other external linear body parameters, i.e. body height, shoulder height, chest depth, front quarter width, hindquarter width, rump length and rump slope in Dorper ewes. A total of 332 young ...

  15. Comparative study of growth and linear body measurements in Anak ...

    African Journals Online (AJOL)

    The study was designed to compare the performance of two different breeds of broilers (Anak and Hubbard) using body weight and body linear measurements. Data on a total of 200 (100 each) Anak and Hubbard broiler breeds were collected weekly and the experiment lasted for 8 weeks. The parameters investigated ...

  16. Miniature ingestible telemeter devices to measure deep-body temperature

    Science.gov (United States)

    Pope, J. M.; Fryer, T. B. (Inventor)

    1976-01-01

    A telemetry device comprised of a pill-size ingestible transmitter developed to obtain deep body temperature measurements of a human is described. The device has particular utility in the medical field where deep body temperatures provide an indication of general health.

  17. Analytic properties of the partial amplitudes in the three-body problem

    International Nuclear Information System (INIS)

    Blokhintsev, L.D.; Simonov, Yu.A.

    1978-01-01

    The singularities of the partial waves for a multiple scattering series of a system of three nonrelativistic particles with arbitrary masses are studied. Both on-shell and off-shell diagrams are considered for binary processes (2→2), break-up processes (2→3) and also three-particle scattering (3→3). For any diagram there are obtained: 1) simple analytic expressions for the loci of the nonpotential singularities of the partial amplitudes, i.e. for the singularities independent of the form of interaction between particles; 2) necessary and sufficient conditions of an existence of these singularities on the physical sheet; 3) a character of the singularities. A criterium is found for the kinematic possibility of a process of N subsequent pair collisions in a classical system of three point like masses with the contact interaction the maximal number Nsub(max) of these collisions is deduced

  18. Key to good fit: body measurement problems specific to key ...

    African Journals Online (AJOL)

    Key to good fit: body measurement problems specific to key dimensions. ... to explore and describe the problems that the South African Clothing Industry currently ... A postal survey was conducted among South African apparel and footwear ...

  19. Predicting live weight using body measurements in Afar goats in ...

    African Journals Online (AJOL)

    Bheema

    Predicting live weight using body measurements in Afar goats in north eastern. Ethiopia ... farmers get value for their stock rather than the middlemen. However ..... of West African long-legged and West African dwarf sheep in Northern Ghana.

  20. Growth performance and certain body measurements of ostrich ...

    African Journals Online (AJOL)

    Growth performance and certain body measurements of ostrich chicks as affected by dietary protein levels during 2–9 weeks of age. Kh M Mahrose, AI Attia, IE Ismail, DE Abou-Kassem, ME Abd El-Hack ...

  1. Measurement of the Lorentz-FitzGerald body contraction

    Science.gov (United States)

    Rafelski, Johann

    2018-02-01

    A complete foundational discussion of acceleration in the context of Special Relativity (SR) is presented. Acceleration allows the measurement of a Lorentz-FitzGerald body contraction created. It is argued that in the back scattering of a probing laser beam from a relativistic flying electron cloud mirror generated by an ultra-intense laser pulse, a first measurement of a Lorentz-FitzGerald body contraction is feasible.

  2. Body composition as measured by in vivo neutron activation analysis

    International Nuclear Information System (INIS)

    Cohn, S.H.; Sawitsky, A.; Vartsky, D.; Yasumura, S.; Zanzi, I.; Gartenhaus, W.; Ellis, K.J.

    1979-01-01

    A large scale study is currently underway on the changes in body composition resulting from the cachexia of malignancy. The ultimate objective of the overall project is to assess the changes in body composition associated with hyperalimentation and other modes of nutritional support to cancer patients. The first phase of this study is now in progress. In this phase, a study is being made of a control group of normal patients to provide baseline data against which data from cancer patients can be evaluated. Total body nitrogen and potassium are measured in a group of normal men and women, and are analyzed as a function of age. Additionally, changes in skeletal mass (total body calcium) are also recorded, and body water is measured simultaneously with the use of tritiated water

  3. A method for measuring the inertia properties of rigid bodies

    Science.gov (United States)

    Gobbi, M.; Mastinu, G.; Previati, G.

    2011-01-01

    A method for the measurement of the inertia properties of rigid bodies is presented. Given a rigid body and its mass, the method allows to measure (identify) the centre of gravity location and the inertia tensor during a single test. The proposed technique is based on the analysis of the free motion of a multi-cable pendulum to which the body under consideration is connected. The motion of the pendulum and the forces acting on the system are recorded and the inertia properties are identified by means of a proper mathematical procedure based on a least square estimation. After the body is positioned on the test rig, the full identification procedure takes less than 10 min. The natural frequencies of the pendulum and the accelerations involved are quite low, making this method suitable for many practical applications. In this paper, the proposed method is described and two test rigs are presented: the first is developed for bodies up to 3500 kg and the second for bodies up to 400 kg. A validation of the measurement method is performed with satisfactory results. The test rig holds a third part quality certificate according to an ISO 9001 standard and could be scaled up to measure the inertia properties of huge bodies, such as trucks, airplanes or even ships.

  4. The development and medical applications of a simple facility for partial body in vivo neutron activation analysis using californium-252 sources

    International Nuclear Information System (INIS)

    Boddy, K.

    1978-11-01

    A simple and cheap facility for partial body neutron activation analysis has been designed, based on the use of two 100 μg 252 Cf neutron sources. The results reported show that calcium can be measured in parts of the body such as the tibia with a precision as good as +- 1.6 % for a radiation dose of 2 rem. The uniformity of the thermal neutron flux density is better than +- 3 % over 10 cm. Some applications of this irradiation facility for studies of trace elements, in particular cadmium in liver and aluminium in liver or brain, have also been explored. However, the sensitivity attainable is not yet sufficient for the study of normal levels, but could be of interest in toxicological investigations

  5. A walker with a device of partial suspension for patients with gait disturbance: body weight supported walker.

    Science.gov (United States)

    Ochi, Mitsuhiro; Makino, Kenichiro; Wada, Futoshi; Saeki, Satoru; Hachisuka, Kenji

    2009-09-01

    We developed a walker, the Body Weight Supported (BWS) Walker, with a device of partial suspension for patients with gait disturbance. It consists of a light frame with casters, a harness, and a winch system. One therapist alone can perform gait training safely with the BWS Walker without any additional physical load, even if a patient has severe gait disturbance, and the therapist can concentrate on evaluating and improving the patient' s standing balance and gait pattern. Because the BWS Walker is less expensive, simpler, and easier to operate than other BWS systems, we believe the BWS Walker can be widely applicable in training for patients with severe and moderate gait disturbance.

  6. Influence of the dose rate on the proliferation capacity of haematopoietic elementary cells in vivo after partial body irradiation

    International Nuclear Information System (INIS)

    Sauer, R.

    1977-01-01

    During direct irradiation of the bone marrow, the dose rate effect was so paradoxical that a temporally protracted exposure has a stronger influence on the proliferation capacity of the elementary cells than one with high dose performance. During the recreation process, the elementary cells proliferated in the sense of a rebound-phaenomenon. This was also referred to the observation that in the non-irradiated bone marrow of animals exposed to partial body irradiation, an activation of the elementary cells started. The results have consequences for the oncological radiotherapy. (orig.) [de

  7. Moderate red-wine consumption partially prevents body weight gain in rats fed a hyperlipidic diet.

    Science.gov (United States)

    Vadillo, Montserrat; Bargalló, Montserrat Vadillo; Ardévol, Anna; Grau, Anna Ardévol; Fernández-Larrea, Juan; Fernández-Larrea, Juan de Dios; Pujadas, Gerard; Anguiano, Gerard Pujadas; Bladé, Cinta; Segarra, Maria Cinta Bladé; Salvadó, Maria Josepa; Rovira, Maria Josepa Salvadó; Arola, Lluís; Ferré, Lluia Arola; Blay, Mayte; Olivé, Mayte Blay

    2006-02-01

    Red wine is a beverage that can exert a broad spectrum of health-promoting actions both in humans and laboratory animal models if consumed moderately. However, information about its effect on body weight is scarce. We have evaluated the effect of moderate red wine consumption on body weight and energy intake in male Zucker lean rats fed a hypercaloric diet for 8 weeks. For this purpose, we used three 5-animal groups: a high-fat diet group (HFD), a high-fat-diet red-wine-drinking group (HFRWD), and a standard diet group (SD). After 8 weeks, the HFRWD group had a lower body weight gain (175.66 +/- 2.78% vs 188.22 +/- 4.83%; Pred wine didn't modified the fed efficiency 0.012 +/- 0.001 g/KJ for HFRWD group versus 0.013 +/- 0.001 g/KJ for the HFD one (P=.080). These findings, though preliminary, show that moderate red wine intake can prevent the increase of body weight by modulating energy intake in a rat diet-induced model of obesity.

  8. Many-body effect in the partial singles N2,3 photoelectron spectroscopy spectrum of atomic Cd

    International Nuclear Information System (INIS)

    Ohno, Masahide

    2008-01-01

    We can extract out the photoelectron kinetic energy (KE) dependent imaginary part of the core-hole self-energy by employing Auger-photoelectron coincidence spectroscopy (APECS). The variation with photoelectron KE in the Auger electron spectroscopy (AES) spectral peak intensity of a selected decay channel measured in coincidence with photoelectrons of a selected KE is the partial singles (non-coincidence) photoelectron spectroscopy (PES) spectrum, i.e., the product of the singles PES one and the branching ratio of the partial Auger decay width of a selected decay channel to the imaginary part of the core-hole self-energy. When a decay channel the partial Auger decay width of which is photoelectron KE independent is selected, we can extract out spectroscopically the imaginary part of the core-hole self-energy because the variation with photoelectron KE in the relative spectral intensity of the partial singles PES spectrum to the singles one is that in the branching ratio of the partial Auger decay width of a selected decay channel. As an example we discussed the N 2,3 -hole self-energy of atomic Cd

  9. National survey of human body radioactivity measured by a mobile whole-body counter and installed whole-body counters

    International Nuclear Information System (INIS)

    Boddy, K.; Fenwick, J.D.; McKenzie, A.L.

    1989-05-01

    Body radioactivity in the general public has been measured in 2339 volunteers throughout the U.K. A mobile whole-body monitor visited collaborating Medical Physics Departments and data were also contributed by Medical Physics Departments possessing installed counters. Levels of body radiocaesium ranged from below detection level to 4149 Bq. Radiocaesium levels were normalised by dividing by the content of natural body potassium-40. In all cases, the dose rate to the body from radiocaesium was less than that from potassium-40. Radiocaesium levels were 2-3 times higher in N.W. England, Scotland and N. Wales than the rest of the country, but this factor is much less than the variation in deposition of Chernobyl radiocaesium. This discrepancy may be accounted for by the nationwide distribution of foodstuffs. At all sites where volunteers were monitored, the ratio of caesium-137/caesium-134 was consistent with a radiocaesium intake attributable primarily to fallout from the Chernobyl fire. (author)

  10. Repair and regeneration of vertebral body after antero-lateral partial vertebrectomy using beta-tricalcium phosphate

    International Nuclear Information System (INIS)

    Momma, Fumiyuki; Amagasa, Masaharu; Nakazawa, Teruo

    2008-01-01

    Antero-lateral partial vertebrectomy (ALPV) was used for decompression in 91 patients with multilevel cervical disorders. The high-speed drill was used to excise about 1/3 of the vertebral body for relief of anterior compression of the cord and nerve roots under the operating microscope. The key point was opening of the medial wall of the foramen of transverse process at the beginning of the ALPV, allowing the determination of the lateral borders of the ALPVs. To repair and regenerate the vertebral body, a beta-tricalcium phosphate (β-TCP) block was trimmed into a cuneiform shape and implanted into the sites of the ALPV excluding the upper and lowermost vertebral bodies. Postoperative computed tomography confirmed that β-TCP was gradually replaced by newly formed bone from the surface towards the center of the block, and that the affected vertebral body was remodeled by 6 to 12 months after the implantation of β-TCP. The cortical bone borders on the bone marrow at the site of the regeneration. The pedicles on the side of the ALPVs were rebuilt during regeneration of the affected vertebrae. Thus, the vertebral foramen of the cervical spine was widened in the anterior direction at the levels of the ALPVs, resulting in restoration of the physiological size of the cervical cord. The cervical curvature remained unchanged and a certain degree of cervical mobility (mean 86%) was preserved in this series. (author)

  11. Histologically Measured Cardiomyocyte Hypertrophy Correlates with Body Height as Strongly as with Body Mass Index

    Directory of Open Access Journals (Sweden)

    Richard E. Tracy

    2011-01-01

    Full Text Available Cardiac myocytes are presumed to enlarge with left ventricular hypertrophy (LVH. This study correlates histologically measured myocytes with lean and fat body mass. Cases of LVH without coronary heart disease and normal controls came from forensic autopsies. The cross-sectional widths of myocytes in H&E-stained paraffin sections followed log normal distributions almost to perfection in all 104 specimens, with constant coefficient of variation across the full range of ventricular weight, as expected if myocytes of all sizes contribute proportionately to hypertrophy. Myocyte sizes increased with height. By regression analysis, height2.7 as a proxy for lean body mass and body mass index (BMI as a proxy for fat body mass, exerted equal effects in the multiple correlation with myocyte volume, and the equation rejected race and sex. In summary, myocyte sizes, as indexes of LVH, suggest that lean and fat body mass may contribute equally.

  12. Diagnostic accuracy of routine postoperative body temperature measurements

    NARCIS (Netherlands)

    Vermeulen, Hester; Storm-Versloot, Marja N.; Goossens, Astrid; Speelman, Peter; Legemate, Dink A.

    2005-01-01

    BACKGROUND: On surgical wards, body temperature is routinely measured, but there is no proof that this is useful for detecting postoperative infection. The aim of this study was to compare temperature measurements (the test) with the confirmed absence or presence of a postoperative infection (the

  13. Repeatability of Objective Measurements of Linear Udder and Body ...

    African Journals Online (AJOL)

    The objective of this study was to estimates the repeatability of objective measurements on linear udder and body conformation traits and to evaluate the objectivity of the measurements in Friesian x Bunaji cows. Data from 50 (F1) Frisian X Bunaji cows collected between 2007 and 2008 at the Dairy Research Farm of the ...

  14. High frequency body mass measurement, feedback, and health behaviors

    NARCIS (Netherlands)

    Kooreman, P.; Scherpenzeel, A.

    We analyze weight and fat percentage measurements of respondents in an online general population panel in the Netherlands, collected using wireless scales, with an average frequency of 1.6 measurements per week. First, we document the existence of a weekly cycle; body mass is lowest on Fridays and

  15. SOI Transistor measurement techniques using body contacted transistors

    International Nuclear Information System (INIS)

    Worley, E.R.; Williams, R.

    1989-01-01

    Measurements of body contacted SOI transistors are used to isolate parameters of the back channel and island edge transistor. Properties of the edge and back channel transistor have been measured before and after X-ray irradiation (ARACOR). The unique properties of the edge transistor are shown to be a result of edge geometry as confirmed by a two dimensional transistor simulator

  16. Treadmill training with partial body weight support compared with conventional gait training for low-functioning children and adolescents with nonspastic cerebral palsy: a two-period crossover study.

    Science.gov (United States)

    Su, Ivan Y W; Chung, Kenny K Y; Chow, Daniel H K

    2013-12-01

    Partial body weight-supported treadmill training has been shown to be effective in gait training for patients with neurological disorders such as spinal cord injuries and stroke. Recent applications on children with cerebral palsy were reported, mostly on spastic cerebral palsy with single subject design. There is lack of evidence on the effectiveness of such training for nonspastic cerebral palsy, particularly those who are low functioning with limited intellectual capacity. This study evaluated the effectiveness of partial body weight-supported treadmill training for improving gross motor skills among these clients. A two-period randomized crossover design with repeated measures. A crossover design following an A-B versus a B-A pattern was adopted. The two training periods consisted of 12-week partial body weight-supported treadmill training (Training A) and 12-week conventional gait training (Training B) with a 10-week washout in between. Ten school-age participants with nonspastic cerebral palsy and severe mental retardation were recruited. The Gross Motor Function Measure-66 was administered immediately before and after each training period. Significant improvements in dimensions D and E of the Gross Motor Function Measure-66 and the Gross Motor Ability Estimator were obtained. Our findings revealed that the partial body weight-supported treadmill training was effective in improving gross motor skills for low-functioning children and adolescents with nonspastic cerebral palsy. .

  17. Pyramidal resistor networks for electrical impedance tomography with partial boundary measurements

    International Nuclear Information System (INIS)

    Borcea, L; Mamonov, A V; Druskin, V; Vasquez, F Guevara

    2010-01-01

    We introduce an inversion algorithm for electrical impedance tomography (EIT) with partial boundary measurements in two dimensions. It gives stable and fast reconstructions using sparse parameterizations of the unknown conductivity on optimal grids that are computed as part of the inversion. We follow the approach in Borcea et al (2008 Inverse Problems 24 035013) and Vasquez (2006 PhD thesis Rice University, Houston, TX, USA) that connects inverse discrete problems for resistor networks to continuum EIT problems, using optimal grids. The algorithm in Borcea et al (2008 Inverse Problems 24 035013) and Vasquez (2006 PhD Thesis Rice University, Houston, TX, USA) is based on circular resistor networks, and solves the EIT problem with full boundary measurements. It is extended in Borcea et al (2010 Inverse Problems 26 045010) to EIT with partial boundary measurements, using extremal quasi-conformal mappings that transform the problem to one with full boundary measurements. Here we introduce a different class of optimal grids, based on resistor networks with pyramidal topology, that is better suited for the partial measurements setup. We prove the unique solvability of the discrete inverse problem for these networks and develop an algorithm for finding them from the measurements of the Dirichlet to Neumann map. Then, we show how to use the networks to define the optimal grids and to approximate the unknown conductivity. We assess the performance of our approach with numerical simulations and compare the results with those in Borcea et al (2010)

  18. Circular resistor networks for electrical impedance tomography with partial boundary measurements

    International Nuclear Information System (INIS)

    Borcea, L; Mamonov, A V; Druskin, V

    2010-01-01

    We introduce an algorithm for the numerical solution of electrical impedance tomography (EIT) in two dimensions, with partial boundary measurements. The algorithm is an extension of the one in Borcea et al (2008 Inverse Problems 24 035013 (31pp)) and Vasquez (2006 PhD Thesis Rice University, Houston, TX, USA) for EIT with full boundary measurements. It is based on resistor networks that arise in finite volume discretizations of the elliptic partial differential equation for the potential on so-called optimal grids that are computed as part of the problem. The grids are adaptively refined near the boundary, where we measure and expect better resolution of the images. They can be used very efficiently in inversion, by defining a reconstruction mapping that is an approximate inverse of the forward map, and acts therefore as a preconditioner in any iterative scheme that solves the inverse problem via optimization. The main result in this paper is the construction of optimal grids for EIT with partial measurements by extremal quasiconformal (Teichmüller) transformations of the optimal grids for EIT with full boundary measurements. We present the algorithm for computing the reconstruction mapping on such grids, and we illustrate its performance with numerical simulations. The results show an interesting trade-off between the resolution of the reconstruction in the domain of the solution and distortions due to artificial anisotropy induced by the distribution of the measurement points on the accessible boundary

  19. Modifications of animal response to Partial Body Hyperthermia (PBH) as a potent radioprotector: Relationships with animal age and sex

    International Nuclear Information System (INIS)

    Alya, G.

    2002-04-01

    Currently available radio protectors are poorly tolerated in man. Thus, the use of the most promising agent, WR 2721 [S-2 (3-aminoprophylamino) ethylphosphoro thioic acid] has been limited due to its poor clinical tolerance. In a search for less toxic and/or without side effects agents, radioprotective effects of partial body hyperthermia (PBH) have been tested on Wistar rats of both sexes at different ages. Groups of male and female rats were irradiated [Total Body Irradiation (TBI)] in a perforated plexi-glass boxes using a 60 Co source. The irradiation dose was 9 Gy which is considered as a lethal dose of 100% of animals (LD 1 00) (the dose rate was = 80-85 rad.min -1 ). Irradiated animals were monitored for 2 weeks at least, and percentage of survival was calculated on the control groups. Partial Body Hyperthermia was carried out 20 hours prior to irradiation of 200-250 gr rats (by immersion of lower parts and legs of rats, in water bath at 43 centigrade for 1 h). Irradiated PBH treated animals were monitored for 30 days after irradiation and the survival percentage was calculated. Our results showed that PBH treatment, can be considered as a radioprotector. Moreover, the results of the undertaken study showed that this response changes as a function of animal age and sex. Thus, PBH was more effective on young rats (males and females), However, after 30 days of irradiation, PBH was more effective on males than females. The conclusion reached by this study is that animal response to PBH decreases with aging. Despite that the precise mechanism by which PBH induces retardation of death and enhance survival of rats is still obscure, Hyperthermia is known to enhance the immune response. Literature reveals that the productions of cytokines such as interferons and interleukins as well as natural killer cell activity are enhanced after hyperthermia. (author)

  20. Partial discharge measurements on 110kV current transformers. Setting the control value. Case study

    Science.gov (United States)

    Dan, C.; Morar, R.

    2017-05-01

    The case study presents a series of partial discharge measurements, reflecting the state of insulation of 110kV CURRENT TRANSFORMERS located in Sibiu county substations. Measurements were performed based on electrical method, using MPD600: an acquisition and analysis toolkit for detecting, recording, and analyzing partial discharges. MPD600 consists of one acquisition unit, an optical interface and a computer with dedicated software. The system allows measurements of partial discharge on site, even in presence of strong electromagnetic interferences because it provides synchronous acquisition from all measurement points. Therefore, measurements, with the ability to be calibrated, do render: - a value subject to interpretation according to IEC 61869-1:2007 + IEC 61869-2:2012 + IEC 61869-3:2011 + IEC 61869-5:2011 and IEC 60270: 2000; - the possibility to determine the quantitative limit of PD (a certain control value) to which the equipment can be operated safely and repaired with minimal costs (relative to the high costs implied by eliminating the consequences of a failure) identified empirically (process in which the instrument transformer subjected to the tests was completely destroyed).

  1. Body awareness: construct and self-report measures.

    Directory of Open Access Journals (Sweden)

    Wolf E Mehling

    Full Text Available Heightened body awareness can be adaptive and maladaptive. Improving body awareness has been suggested as an approach for treating patients with conditions such as chronic pain, obesity and post-traumatic stress disorder. We assessed the psychometric quality of selected self-report measures and examined their items for underlying definitions of the construct.PubMed, PsychINFO, HaPI, Embase, Digital Dissertations Database.Abstracts were screened; potentially relevant instruments were obtained and systematically reviewed. Instruments were excluded if they exclusively measured anxiety, covered emotions without related physical sensations, used observer ratings only, or were unobtainable. We restricted our study to the proprioceptive and interoceptive channels of body awareness. The psychometric properties of each scale were rated using a structured evaluation according to the method of McDowell. Following a working definition of the multi-dimensional construct, an inter-disciplinary team systematically examined the items of existing body awareness instruments, identified the dimensions queried and used an iterative qualitative process to refine the dimensions of the construct.From 1,825 abstracts, 39 instruments were screened. 12 were included for psychometric evaluation. Only two were rated as high standard for reliability, four for validity. Four domains of body awareness with 11 sub-domains emerged. Neither a single nor a compilation of several instruments covered all dimensions. Key domains that might potentially differentiate adaptive and maladaptive aspects of body awareness were missing in the reviewed instruments.Existing self-report instruments do not address important domains of the construct of body awareness, are unable to discern between adaptive and maladaptive aspects of body awareness, or exhibit other psychometric limitations. Restricting the construct to its proprio- and interoceptive channels, we explore the current understanding

  2. A new method of body habitus correction for total body potassium measurements

    International Nuclear Information System (INIS)

    O'Hehir, S; Green, S; Beddoe, A H

    2006-01-01

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use

  3. A new method of body habitus correction for total body potassium measurements

    Energy Technology Data Exchange (ETDEWEB)

    O' Hehir, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Green, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Beddoe, A H [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom)

    2006-09-07

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use.

  4. Measuring Parameters of Massive Black Hole Binaries with Partially-Aligned Spins

    Science.gov (United States)

    Lang, Ryan N.; Hughes, Scott A.; Cornish, Neil J.

    2010-01-01

    It is important to understand how well the gravitational-wave observatory LISA can measure parameters of massive black hole binaries. It has been shown that including spin precession in the waveform breaks degeneracies and produces smaller expected parameter errors than a simpler, precession-free analysis. However, recent work has shown that gas in binaries can partially align the spins with the orbital angular momentum, thus reducing the precession effect. We show how this degrades the earlier results, producing more pessimistic errors in gaseous mergers. However, we then add higher harmonics to the signal model; these also break degeneracies, but they are not affected by the presence of gas. The harmonics often restore the errors in partially-aligned binaries to the same as, or better than/ those that are obtained for fully precessing binaries with no harmonics. Finally, we investigate what LISA measurements of spin alignment can tell us about the nature of gas around a binary,

  5. Measurements of whole-body radioactivity in the UK population

    International Nuclear Information System (INIS)

    Fenwick, J.D.; Boddy, K.; McKenzie, A.L.; Oxby, C.B.

    1992-01-01

    A national survey of whole-body radioactivity was undertaken. A mobile whole-body counter visited collaborating Medical Physics Departments and Hospitals in England and Wales. Data were also obtained from an installed whole-body counter at the West Cumberland Hospital, Whitehaven, and from a control site at Addenbrooke's Hospital, Cambridge. 1657 volunteer members of the public were measured, including 162 children. 36% of volunteers had been measured in a similar survey 2 years earlier, and showed between a two and five fold reduction in body radiocaesium. No radiocaesium was detected in 54% of people measured. Measurements showed a progressive fall over the course of the study, reaching a baseline of 0.3 Bq 137 Cs/gK. In 1989, the additional radiation dose incurred from radiocaesium varied from a maximum of 4.1 μSv in Cumbria to 1.5 μSv in the South East, compared with the average annual radiation dose of 2500 μSv due to all other causes. No other gamma-emitting radionuclides were found. Results are consistent with Chernobyl as the source of the radiocaesium detected. (author)

  6. Convergence of Algorithms for Reconstructing Convex Bodies and Directional Measures

    DEFF Research Database (Denmark)

    Gardner, Richard; Kiderlen, Markus; Milanfar, Peyman

    2006-01-01

    We investigate algorithms for reconstructing a convex body K in Rn from noisy measurements of its support function or its brightness function in k directions u1, . . . , uk. The key idea of these algorithms is to construct a convex polytope Pk whose support function (or brightness function) best...

  7. Direct measurement of the partial decay energy of 7Be inner bremstrahlung spectrum

    International Nuclear Information System (INIS)

    Sanjeeviah, H.; Sanjeeviah, B.

    1978-01-01

    The inner bremsstrahlung spectrum accompanying orbital electron capture decay of 7 Be to the first excited state of 7 Li was measured in coincidence with 477 keV gamma rays. From the Jauch plot of the spectrum the partial decay energy was found to be 394 +- 16 keV. The shape factor of the inner bremsstrahlung spectrum close to the end point was accurately determined. It was found to be a constant X(1.001 +- 0.002) (author)

  8. Bioimpedance measurement of body water correlates with measured volume balance in injured patients.

    Science.gov (United States)

    Rosemurgy, A S; Rodriguez, E; Hart, M B; Kurto, H Z; Albrink, M H

    1993-06-01

    Bioimpedance technology is being used increasingly to determine drug volume of distribution, body water status, and nutrition repletion. Its accuracy in patients experiencing large volume flux is not established. To address this, we undertook this prospective study in 54 consecutive seriously injured adults who had emergency celiotomy soon after arrival in the emergency department. Bioimpedance measurements were obtained in the emergency department before the patient was transported to the operating room, on completion of celiotomy, and 24 hours and 48 hours after celiotomy. Bioimpedance measurements of body water were compared with measured fluid balance. If insensible losses are subtracted from measured fluid balance, the percentage of body weight, which is body water determined by bioimpedance, closely follows fluid flux. This study supports the use of bioimpedance measurements in determining total body water even during periods of surgery, blood loss, and vigorous resuscitation.

  9. On the Smooth Dependence of SRB Measures for Partially Hyperbolic Systems

    Science.gov (United States)

    Zhang, Zhiyuan

    2018-02-01

    In this paper, we study the differentiability of SRB measures for partially hyperbolic systems. We show that for any {s ≥ 1}, for any integer {ℓ ≥ 2}, any sufficiently large r, any φ \\in Cr(T, R)} such that the map {f : T^2 \\to T^2, f(x,y) = (ℓ x, y + φ(x))} is {C^r}-stably ergodic, there exists an open neighbourhood of f in {C^r(T^2,T^2)} such that any map in this neighbourhood has a unique SRB measure with {C^{s-1}} density, which depends on the dynamics in a {C^s} fashion. We also construct a C^{∞} mostly contracting partially hyperbolic diffeomorphism {f: T^3 \\to T^3} such that all f' in a C 2 open neighbourhood of f possess a unique SRB measure {μ_{f'}} and the map {f' \\mapsto μ_{f'}} is strictly Hölder at f, in particular, non-differentiable. This gives a partial answer to Dolgopyat's Question 13.3 in Dolgopyat (Commun Math Phys 213:181-201, 2000).

  10. Investigation of human body potential measured by a non-contact measuring system.

    Science.gov (United States)

    Ichikawa, Norimitsu

    2016-12-07

    A human body is occasionally electrified in a room. This charged object will be a source of electrostatic accidents, including the malfunction of electronic equipment. Hence, prevention of these accidents is required. Accidents occasionally occur, even though antistatic clothes and shoes are used. One of the causes for these accidents is that there is a lack of the preventive measures. This situation occurs when using, for example, unconductive wax. In this study, human body potential (voltage) is measured using a non-contact measuring system. An investigation of the human body's voltage when using this system is conducted. The result demonstrates that the voltage of a human body wearing antistatic clothes and shoes or light clothes and slippers exceeds a malfunctioning voltage of a microelectronics device when the body walks on floors. Thus, accidents may occur even if a human body wearing the antistatic clothes walks on flooring. These results will be useful in estimating determination whether electrostatic accidents occur or not.

  11. Measurement of body fat and hydration of the fat-free body in health and disease

    International Nuclear Information System (INIS)

    Streat, S.J.; Beddoe, A.H.; Hill, G.L.

    1985-01-01

    Body fat mass, fat-free body mass and body water are basic components of body composition which are used in nutritional and metabolic studies and in patient care. A method of measuring total body fat (TBF), fat-free mass (FFM) and its hydration (TBW/FFM) involving prompt gamma in vivo neutron activation analysis (IVNAA) and tritium dilution has been compared with the more traditional methods of densitometry and skinfold anthropometry in 36 normal volunteers, and with skinfold anthropometry in 56 patients presenting for nutritional support. While the mean values of TBF were in reasonable agreement for the three methods in normals it was founds that skinfold anthropometry underestimated TBF relative to the IVNAA/tritium method by, on average, 3.0 kg (19%) in patients. Furthermore, the ranges of values in normals of the ratio TBW/FFM for the anthropometric (0.62 to 0.80) and densitometric (0.65 to 0.80) methods were much wider than the range for the IVNAA/tritium method (0.69 to 0.76), in which TBW was measured by tritium dilution in all cases. In the patients, the ranges of this ratio were 0.52 to 0.90 for the anthropometric method and 0.67 to 0.82 for the IVNAA/tritium method; clearly anthropometry yields values of TBW/FFM which are outside accepted biological limits. On the basis of these findings, ranges of TBW/FFM are suggested for both normal adults (0.69 to 0.75) and patients requiring nutritional support (0.67 to 0.83). Finally it is concluded that the IVNAA/tritium method is a suitable method for measuring TBF and FFM and particularly so when body composition is abnormal

  12. West African donkey's liveweight estimation using body measurements

    Directory of Open Access Journals (Sweden)

    Pierre Claver Nininahazwe

    2017-10-01

    Full Text Available Aim: The objective of this study was to determine a formula for estimating the liveweight in West African donkeys. Materials and Methods: Liveweight and a total of 6 body measurements were carried out on 1352 donkeys from Burkina Faso, Mali, Niger, and Senegal. The correlations between liveweight and body measurements were determined, and the most correlated body measurements with liveweight were used to establish regression lines. Results: The average weight of a West African donkey was 126.0±17.1 kg, with an average height at the withers of 99.5±3.67 cm; its body length was 104.4±6.53 cm, and a heart girth (HG of 104.4±6.53 cm. After analyzing the various regression lines and correlations, it was found that the HG could better estimate the liveweight of West African donkeys by simple linear regression method. Indeed, the liveweight (LW showed a better correlation with the HG (R2=0.81. The following formulas (Equations 1 and 2 could be used to estimate the LW of West Africa donkeys. Equation 1: Estimated LW (kg = 2.55 x HG (cm - 153.49; Equation 2: Estimated LW (kg = Heart girth (cm2.68 / 2312.44. Conclusion: The above formulas could be used to manufacture weighing tape to be utilized by veterinary clinicians and farmers to estimate donkey's weight in the view of medication and adjustment of load.

  13. A bedside measure of body composition in Duchenne muscular dystrophy.

    Science.gov (United States)

    Elliott, Sarah A; Davidson, Zoe E; Davies, Peter S W; Truby, Helen

    2015-01-01

    In clinical practice, monitoring body composition is a critical component of nutritional assessment and weight management in boys with Duchenne muscular dystrophy. We aimed to evaluate the accuracy of a simple bedside measurement tool for body composition, namely bioelectrical impedance analysis, in boys with Duchenne muscular dystrophy. Measures of fat-free mass were determined using a bioelectrical impedance analysis machine and compared against estimations obtained from a reference body composition model. Additionally, the use of raw impedance values was analyzed using three existing predictive equations for the estimation of fat-free mass. Accuracy of bioelectrical impedance analysis was assessed by comparison against the reference model by calculation of biases and limits of agreement. Body composition was measured in 10 boys with Duchenne muscular dystrophy, mean age 9.01 ± 2.34 years. The bioelectrical impedance analysis machine values of fat-free mass were on average 2.3 ± 14.1 kg higher than reference values. Limits of agreement (based on 95% confidence interval of the mean) were -7.4 to 2.9 kg. There was a significant correlation between the mean fat-free mass and difference in fat-free mass between the bioelectrical impedance analysis machine and the reference model (r = -0.86; P = 0.02) suggesting that the bias was not consistent across the range of measurements. The most accurate predictive equation for the estimation of fat-free mass using raw impedance values was the equation by Pietrobelli et al. (mean difference, -0.7 kg; 95% limits of agreement, -3.5 to 2.0 kg). In a clinical setting, where a rapid assessment of body composition is advantageous, the use of raw impedance values, combined with the equation by Pietrobelli et al., is recommended for the accurate estimation of fat-free mass, in boys with Duchenne muscular dystrophy. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Association of macrophage inhibitory cytokine-1 with nutritional status, body composition and bone mineral density in patients with anorexia nervosa: the influence of partial realimentation.

    Science.gov (United States)

    Dostálová, Ivana; Kaválková, Petra; Papežová, Hana; Domluvilová, Daniela; Zikán, Vít; Haluzík, Martin

    2010-04-23

    Macrophage inhibitory cytokine-1 (MIC-1) is a key inducer of cancer-related anorexia and weight loss. However, its possible role in the etiopathogenesis of nutritional disorders of other etiology such as anorexia nervosa (AN) is currently unknown. We measured fasting serum concentrations of MIC-1 in patients with AN before and after 2-month nutritional treatment and explored its relationship with nutritional status, metabolic and biochemical parameters. Sixteen previously untreated women with AN and twenty-five normal-weight age-matched control women participated in the study. We measured serum concentrations of MIC-1 and leptin by ELISA, free fatty acids by enzymatic colorimetric assay, and biochemical parameters by standard laboratory methods; determined resting energy expenditure by indirect calorimetry; and assessed bone mineral density and body fat content by dual-energy X-ray absorptiometry. ANOVA, unpaired t-test or Mann-Whitney test were used for groups comparison as appropriate. The comparisons of serum MIC-1 levels and other studied parameters in patients with AN before and after partial realimentation were assessed by paired t-test or Wilcoxon Signed Rank Test as appropriate. At baseline, fasting serum MIC-1 concentrations were significantly higher in patients with AN relative to controls. Partial realimentation significantly reduced serum MIC-1 concentrations in patients with AN but it still remained significantly higher compared to control group. In AN group, serum MIC-1 was inversely related to Buzby nutritional risk index, serum insulin-like growth factor-1, serum glucose, serum total protein, serum albumin, and lumbar bone mineral density and it significantly positively correlated with the duration of AN and age. MIC-1 concentrations in AN patients are significantly higher relative to healthy women. Partial realimentation significantly decreased MIC-1 concentration in AN group. Clinical significance of these findings needs to be further clarified.

  15. Association of macrophage inhibitory cytokine-1 with nutritional status, body composition and bone mineral density in patients with anorexia nervosa: the influence of partial realimentation

    Directory of Open Access Journals (Sweden)

    Zikán Vít

    2010-04-01

    Full Text Available Abstract Background Macrophage inhibitory cytokine-1 (MIC-1 is a key inducer of cancer-related anorexia and weight loss. However, its possible role in the etiopathogenesis of nutritional disorders of other etiology such as anorexia nervosa (AN is currently unknown. Methods We measured fasting serum concentrations of MIC-1 in patients with AN before and after 2-month nutritional treatment and explored its relationship with nutritional status, metabolic and biochemical parameters. Sixteen previously untreated women with AN and twenty-five normal-weight age-matched control women participated in the study. We measured serum concentrations of MIC-1 and leptin by ELISA, free fatty acids by enzymatic colorimetric assay, and biochemical parameters by standard laboratory methods; determined resting energy expenditure by indirect calorimetry; and assessed bone mineral density and body fat content by dual-energy X-ray absorptiometry. ANOVA, unpaired t-test or Mann-Whitney test were used for groups comparison as appropriate. The comparisons of serum MIC-1 levels and other studied parameters in patients with AN before and after partial realimentation were assessed by paired t-test or Wilcoxon Signed Rank Test as appropriate. Results At baseline, fasting serum MIC-1 concentrations were significantly higher in patients with AN relative to controls. Partial realimentation significantly reduced serum MIC-1 concentrations in patients with AN but it still remained significantly higher compared to control group. In AN group, serum MIC-1 was inversely related to Buzby nutritional risk index, serum insulin-like growth factor-1, serum glucose, serum total protein, serum albumin, and lumbar bone mineral density and it significantly positively correlated with the duration of AN and age. Conclusions MIC-1 concentrations in AN patients are significantly higher relative to healthy women. Partial realimentation significantly decreased MIC-1 concentration in AN group

  16. A Measure of the Conformity of a Parameter Set to a Trend: The Partially Ordered Case.

    Science.gov (United States)

    1983-05-01

    A-A3214 A MEASURE OF THE CONFORMIYO QAPARAMEfERSETO QA / TREND: THE PARTIAL .U) IOWA UNIV IOWA CIT DEPT OF ......STATISTICS AND ACTURIAL SCIENCE.T...and j with i o j. Such a vector 0 = (Oi,0j,.... 0k is said to be isotone (with respect to _). In studying such inference procedures it is helpful to...noticed that none of the measures studied here are applicable in alIl the situations considered. In studying locat ion pa rameter- wlhich are not

  17. NATURAL USER INTERFACE SENSORS FOR HUMAN BODY MEASUREMENT

    Directory of Open Access Journals (Sweden)

    J. Boehm

    2012-08-01

    Full Text Available The recent push for natural user interfaces (NUI in the entertainment and gaming industry has ushered in a new era of low cost three-dimensional sensors. While the basic idea of using a three-dimensional sensor for human gesture recognition dates some years back it is not until recently that such sensors became available on the mass market. The current market leader is PrimeSense who provide their technology for the Microsoft Xbox Kinect. Since these sensors are developed to detect and observe human users they should be ideally suited to measure the human body. We describe the technology of a line of NUI sensors and assess their performance in terms of repeatability and accuracy. We demonstrate the implementation of a prototype scanner integrating several NUI sensors to achieve full body coverage. We present the results of the obtained surface model of a human body.

  18. Natural User Interface Sensors for Human Body Measurement

    Science.gov (United States)

    Boehm, J.

    2012-08-01

    The recent push for natural user interfaces (NUI) in the entertainment and gaming industry has ushered in a new era of low cost three-dimensional sensors. While the basic idea of using a three-dimensional sensor for human gesture recognition dates some years back it is not until recently that such sensors became available on the mass market. The current market leader is PrimeSense who provide their technology for the Microsoft Xbox Kinect. Since these sensors are developed to detect and observe human users they should be ideally suited to measure the human body. We describe the technology of a line of NUI sensors and assess their performance in terms of repeatability and accuracy. We demonstrate the implementation of a prototype scanner integrating several NUI sensors to achieve full body coverage. We present the results of the obtained surface model of a human body.

  19. Inertial Navigation System/Doppler Velocity Log (INS/DVL Fusion with Partial DVL Measurements

    Directory of Open Access Journals (Sweden)

    Asaf Tal

    2017-02-01

    Full Text Available The Technion autonomous underwater vehicle (TAUV is an ongoing project aiming to develop and produce a small AUV to carry on research missions, including payload dropping, and to demonstrate acoustic communication. Its navigation system is based on an inertial navigation system (INS aided by a Doppler velocity log (DVL, magnetometer, and pressure sensor (PS. In many INSs, such as the one used in TAUV, only the velocity vector (provided by the DVL can be used for aiding the INS, i.e., enabling only a loosely coupled integration approach. In cases of partial DVL measurements, such as failure to maintain bottom lock, the DVL cannot estimate the vehicle velocity. Thus, in partial DVL situations no velocity data can be integrated into the TAUV INS, and as a result its navigation solution will drift in time. To circumvent that problem, we propose a DVL-based vehicle velocity solution using the measured partial raw data of the DVL and additional information, thereby deriving an extended loosely coupled (ELC approach. The implementation of the ELC approach requires only software modification. In addition, we present the TAUV six degrees of freedom (6DOF simulation that includes all functional subsystems. Using this simulation, the proposed approach is evaluated and the benefit of using it is shown.

  20. Body mass index and blood pressure measurement during pregnancy.

    LENUS (Irish Health Repository)

    Hogan, Jennifer L

    2012-02-01

    OBJECTIVE: The accurate measurement of blood pressure requires the use of a large cuff in subjects with a high mid-arm circumference (MAC). This prospective study examined the need for a large cuff during pregnancy and its correlation with maternal obesity. METHODS: Maternal body mass index (BMI), fat mass, and MAC were measured. RESULTS: Of 179 women studied, 15.6% were obese. With a BMI of level 1 obesity, 44% needed a large cuff and with a BMI of level 2 obesity 100% needed a large cuff. CONCLUSION: All women booking for antenatal care should have their MAC measured to avoid the overdiagnosis of pregnancy hypertension.

  1. MEASUREMENT OF THE B{sup 0} LIFETIME USING PARTIAL RECONSTRUCTION

    Energy Technology Data Exchange (ETDEWEB)

    Krishnamurthy, M

    2003-10-31

    We present here the first measurement of the B{sup 0} lifetime using partial reconstruction in B{sup 0} {yields} D*{sup -} {rho}{sup +} decay. A sample of approximately 5500 B{sup 0} {yields} D*{sup -} {rho}{sup +} events were identified among 22.7 million B{bar B} pairs collected by the BABAR experiment during the years 1999-2000. With this data, the B{sup 0} lifetime is measured to be 1.616 {+-} 0.064 {+-} 0.075 ps, in good agreement with the world average. This measurement demonstrates that is it possible to use this technique to perform time-dependent B{sup 0} decay analysis that is central to the measurement of the charge-parity (CP) asymmetries. Investigation of CP observables through measurements of the decays of B{sup 0} mesons is the primary goal of the BABAR experiment at the PEP-II storage ring located at Stanford Linear Accelerator Center (SLAC). As the B{sup 0} particle decays to final states that are directly sensitive to the CP parameter {gamma} are highly suppressed, a promising alternative approach is to use the final state B{sup 0} {yields} D*h. Using the partial event reconstruction analysis method it is possible to compensate for the small CP asymmetries in this decay.

  2. Effect of surface potential and intrinsic magnetic field on resistance of a body in a supersonic flow of rarefied partially ionized gas

    International Nuclear Information System (INIS)

    Shuvalov, V.A.

    1986-01-01

    The character of flow over a body, structure of the perturbed zone, and flow resistance in a supersonic flow of rarefied partially ionized gas are determined by the intrinsic magnetic field and surface potential of the body. There have been practically no experimental studies of the effect of intrinsic magnetic field on flow of a rarefied plasma. Studies of the effect of surface potential have been limited to the case R/λd 10 2 (where R is the characteristic dimension of the body and λd is the Debye radius). At the same time R/λd > 10 2 , the regime of flow over a large body, is of the greatest practical interest. The present study will consider the effect of potential and intrinsic magnetic field on resistance of a large (R/λd > 10 2 ) axisymmetric body (disk, sphere) in a supersonic flow of rarefield partially ionized gas

  3. Changes in body chemical composition with age measured by total-body neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Vaswani, A.; Zanzi, I.; Aloia, J.F.; Roginsky, M.S.; Ellis, K.J.

    1976-01-01

    Total-body levels of calcium and phosphorus (reflecting skeletal mass) and total-body levels of potassium (reflecting muscle mass) were measured by neutron activation analysis in 39 men and 40 women ages 30 to 90 yr. In order to intercompare the total body calcium (TBCa) values in a heterogeneous population, such as this, it was necessary to normalize the data for skeletal size. The normalization consisted of dividing the absolute calcium level by the predicted calcium level for each individual matched to a set of critical parameters. The parameter used in the computation of normal values were age, sex, muscle mass, i.e., total body potassium (TBK) and height. For the calcium data of the women, it was necessary to add an age correction factor after the age of 55 yr. The calcium ratio (mean ratio of the predicted to measured TBCa) in men was 1.000 +- 7.8 percent and in women 0.996 +- 7.1 percent. The TBCa of normal males and females can thus be predicted to +-13 percent (at the 90 percent confidence level). An exception to this was found in males (70 to 90 yr) who exhibited a mean calcium ratio greater than 1.13

  4. Sensor for Measuring Hydrogen Partial Pressure in Parabolic Trough Power Plant Expansion Tanks

    Energy Technology Data Exchange (ETDEWEB)

    Glatzmaier, Greg C.; Cooney, Daniel A.

    2017-06-27

    The National Renewable Energy Laboratory and Acciona Energy North America are working together to design and implement a process system that provides a permanent solution to the issue of hydrogen buildup at parabolic trough power plants. We are pursuing a method that selectively removes hydrogen from the expansion tanks that serve as reservoirs for the heat transfer fluid (HTF) that circulates in the collector field and power block components. Our modeling shows that removing hydrogen from the expansion tanks at a design rate reduces and maintains dissolved hydrogen in the circulating HTF to a selected target level. Our collaborative work consists of several tasks that are needed to advance this process concept to a development stage, where it is ready for implementation at a commercial power plant. Our main effort is to design and evaluate likely process-unit operations that remove hydrogen from the expansion tanks at a specified rate. Additionally, we designed and demonstrated a method and instrumentation to measure hydrogen partial pressure and concentration in the expansion-tank headspace gas. We measured hydrogen partial pressure in the headspace gas mixture using a palladium-alloy membrane, which is permeable exclusively to hydrogen. The membrane establishes a pure hydrogen gas phase that is in equilibrium with the hydrogen in the gas mixture. We designed and fabricated instrumentation, and demonstrated its effectiveness in measuring hydrogen partial pressures over a range of three orders of magnitude. Our goal is to install this instrument at the Nevada Solar One power plant and to demonstrate its effectiveness in measuring hydrogen levels in the expansion tanks under normal plant operating conditions.

  5. Developing a Novel Measure of Body Satisfaction Using Virtual Reality

    Science.gov (United States)

    Purvis, Clare K.; Jones, Megan; Bailey, Jakki O.; Bailenson, Jeremy; Taylor, C. Barr

    2015-01-01

    Body image disturbance (BID), considered a key feature in eating disorders, is a pervasive issue among young women. Accurate assessment of BID is critical, but the field is currently limited to self-report assessment methods. In the present study, we build upon existing research, and explore the utility of virtual reality (VR) to elicit and detect changes in BID across various immersive virtual environments. College-aged women with elevated weight and shape concerns (n = 38) and a non-weight and shape concerned control group (n = 40) were randomly exposed to four distinct virtual environments with high or low levels of body salience and social presence (i.e., presence of virtual others). Participants interacted with avatars of thin, normal weight, and overweight body size (BMI of approximately 18, 22, and 27 respectively) in virtual social settings (i.e., beach, party). We measured state-level body satisfaction (state BD) immediately after exposure to each environment. In addition, we measured participants’ minimum interpersonal distance, visual attention, and approach preference toward avatars of each size. Women with higher baseline BID reported significantly higher state BD in all settings compared to controls. Both groups reported significantly higher state BD in a beach with avatars as compared to other environments. In addition, women with elevated BID approached closer to normal weight avatars and looked longer at thin avatars compared to women in the control group. Our findings indicate that VR may serve as a novel tool for measuring state-level BID, with applications for measuring treatment outcomes. Implications for future research and clinical interventions are discussed. PMID:26469860

  6. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  7. Body Fat Measurements in Singaporean Adults Using Four Methods

    Directory of Open Access Journals (Sweden)

    Xinyan Bi

    2018-03-01

    Full Text Available Few studies have been conducted to measure body composition in Asian populations. In this study, we determined the percent body fat (PBF by using dual-energy X-ray absorptiometry (DEXA, air-displacement plethysmography (ADP or BOD POD, bioelectrical impedance analysis (BIA and skinfold (SKF in 445 healthy Singaporean adults. We observed that the BOD POD, BIA and SKF estimates of PBF were highly correlated with that from DEXA (as a reference method among Singaporean adults. However, they all underestimated PBF (differences of 3.9% for BOD POD, 5.6% for BIA and 12.5% for SKF. Our results filled a gap in the literature by testing the relationships between DEXA and BOD POD, BIA and SKF in a large sample with a wide range of body mass index (BMI from 16.1 to 37.5 kg/m2 and age from 21 to 69.2 years. The differences of PBF measured by different methods were dependent on age, gender and ethnicity. No significant difference was observed between DEXA and BOD POD in men aged > 40 or in BMI tertile 3. However, the mean difference between DEXA and BOD POD was significant in women. Different measuring methods of estimating PBF therefore must be cautiously interpreted.

  8. Partial Body Weight-Supported Treadmill Training in Patients With Parkinson Disease: Impact on Gait and Clinical Manifestation.

    Science.gov (United States)

    Ganesan, Mohan; Sathyaprabha, Talakad N; Pal, Pramod Kumar; Gupta, Anupam

    2015-09-01

    To evaluate the effect of conventional gait training (CGT) and partial weight-supported treadmill training (PWSTT) on gait and clinical manifestation. Prospective experimental research design. Hospital. Patients with idiopathic Parkinson disease (PD) (N=60; mean age, 58.15±8.7y) on stable dosage of dopaminomimetic drugs were randomly assigned into the 3 following groups (20 patients in each group): (1) nonexercising PD group, (2) CGT group, and (3) PWSTT group. The interventions included in the study were CGT and PWSTT. The sessions of the CGT and PWSTT groups were given in patient's self-reported best on status after regular medications. The interventions were given for 30min/d, 4d/wk, for 4 weeks (16 sessions). Clinical severity was measured by the Unified Parkinson Disease Rating Scale (UPDRS) and its subscores. Gait was measured by 2 minutes of treadmill walking and the 10-m walk test. Outcome measures were evaluated in their best on status at baseline and after the second and fourth weeks. Four weeks of CGT and PWSTT gait training showed significant improvements of UPDRS scores, its subscores, and gait performance measures. Moreover, the effects of PWSTT were significantly better than CGT on most measures. PWSTT is a promising intervention tool to improve the clinical and gait outcome measures in patients with PD. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. Measurement of partial discharge inception characteristics in sub-cooled liquid nitrogen

    International Nuclear Information System (INIS)

    Koo, J.Y.; Lee, S.H.; Shin, W.J.; Khan, Umer A.; Oh, S.H.; Seong, J.K.; Lee, B.W.

    2011-01-01

    We measured partial discharge and partial discharge initiation voltage of subcooled liquid nitrogen. Various kinds of test samples have been prepared. Sub-cooled temperature in liquid nitrogen were changed. The number of PD pluses were decreased when 68 K liquid nitrogen was used. Sub-cooled liquid nitrogen has positive effects to suppress PD activities. Partial discharge (PD) measurement is one of the effective diagnostic techniques to predict abnormal high voltage dielectric insulation conditions of the electric equipments. PD diagnostic techniques were also could be utilized to evaluate the conditions of cryogenic dielectric insulation media of high temperature superconducting electric equipment in liquid nitrogen. Generally, liquid nitrogen at 77 K is used as cryogenic and dielectric media for high temperature superconducting devices for high voltage electric power systems. But due to generation of bubbles during quench conditions which cause harmful effect on the properties of liquid nitrogen insulation, sub-cooled nitrogen under 77 K was also employed to suppress bubble formation. In this work, investigation of PD characteristics of sub-cooled liquid nitrogen was conducted in order to clarify the relation between PD inception and the temperature of liquid nitrogen. It was observed that measured PDIV (PD inception voltage) shows little differences according to the sub-cooled temperature of liquid nitrogen, but the magnitude and total numbers of PD has been slightly decreased according the decrease of cooled temperature of liquid nitrogen. From experimental results, it was deduced that the sub-cooled liquid nitrogen from 68 K to 77 K, could be applicable without any considerations of the variation of PDIV.

  10. MEASUREMENT OF THE B0 ---> D*- A+(1) BRANCHING FRACTION WITH PARTIALLY RECONSTRUCTED D*

    Energy Technology Data Exchange (ETDEWEB)

    Salvatore, Pasquale F

    2002-07-26

    The B{sup 0} {yields} D*{sup -} a{sub 1}{sup +} branching fraction has been measured with data collected by the BaBar experiment in 1999 and 2000 corresponding to a total integrated luminosity of 20.6 fb{sup -1}. Signal events have been selected using a partial reconstruction technique, in which only the a{sub 1}{sup +} and the slow pion ({pi}{sub s}) from the D*{sup -} decay are identified. A signal yield of 18400 {+-} 1200 events has been found, corresponding to a preliminary branching fraction of (1.20 {+-} 0.07(stat) {+-} 0.14(syst))%.

  11. Measurement and prediction of the solubility of acid gases in monoethanolamine solutions at low partial pressures

    Energy Technology Data Exchange (ETDEWEB)

    Nasir, P; Mather, A E

    1977-12-01

    An apparatus for the determination of the solubility of hydrogen sulfide, carbon dioxide, and their mixtures in ethanolamine solutions at low pressures is described. With this apparatus, the solubility of H/sub 2/S, CO/sub 2/ and their mixtures in aqueous solutions of monoethanolamine was measured at partial pressures between 0.001 kPa and 9 kPa at temperatures of 80 and 100/sup 0/C. The results for the mixture were compared with two methods of prediction based on a thermodynamic model. 6 figures, 4 tables.

  12. Hydrogen production by the iodine-sulphur thermochemical cycle. Total and partial pressure measurements

    International Nuclear Information System (INIS)

    D Doizi; V Dauvois; J L Roujou; V Delanne; P Fauvet; B Larousse; O Hercher; P Carles; C Moulin

    2006-01-01

    The iodine sulphur thermochemical cycle appears to be one of the most promising candidate for the massive production of hydrogen using nuclear energy. The key step in this cycle is the HI distillation section which must be optimized to get a good efficiency of the overall cycle. The concept of reactive versus extractive distillation of HI has been proposed because of its potentiality. The design and the optimization of the reactive distillation column requires the knowledge of the liquid vapour equilibrium over the ternary HI-I 2 -H 2 O mixtures up to 300 C and 100 bars. A general methodology based on three experimental devices imposed by the very corrosive and concentrated media will be described: 1) I1 for the total pressure measurement versus different ternary compositions. 2) I2 for the partial and total pressure measurements around 130 C and 2 bars to validate the choice of the analytical optical 'online' techniques we have proposed. 3) I3 for the partial and total pressures measurements in the process domain. The results obtained on pure samples, binary mixtures HI-H 2 O and ternary mixtures using an experimental design analysis in the experimental device I2 will be discussed. (authors)

  13. Robust estimation of partially linear models for longitudinal data with dropouts and measurement error.

    Science.gov (United States)

    Qin, Guoyou; Zhang, Jiajia; Zhu, Zhongyi; Fung, Wing

    2016-12-20

    Outliers, measurement error, and missing data are commonly seen in longitudinal data because of its data collection process. However, no method can address all three of these issues simultaneously. This paper focuses on the robust estimation of partially linear models for longitudinal data with dropouts and measurement error. A new robust estimating equation, simultaneously tackling outliers, measurement error, and missingness, is proposed. The asymptotic properties of the proposed estimator are established under some regularity conditions. The proposed method is easy to implement in practice by utilizing the existing standard generalized estimating equations algorithms. The comprehensive simulation studies show the strength of the proposed method in dealing with longitudinal data with all three features. Finally, the proposed method is applied to data from the Lifestyle Education for Activity and Nutrition study and confirms the effectiveness of the intervention in producing weight loss at month 9. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Anorexia nervosa and nutritional assessment: contribution of body composition measurements.

    Science.gov (United States)

    Mattar, Lama; Godart, Nathalie; Melchior, Jean Claude; Pichard, Claude

    2011-06-01

    The psychiatric condition of patients suffering from anorexia nervosa (AN) is affected by their nutritional status. An optimal assessment of the nutritional status of patients is fundamental in understanding the relationship between malnutrition and the psychological symptoms. The present review evaluates some of the available methods for measuring body composition in patients with AN. We searched literature in Medline using several key terms relevant to the present review in order to identify papers. Only articles in English or French were reviewed. A brief description is provided for each body composition technique, with its applicability in AN as well as its limitation. All methods of measuring body composition are not yet validated and/or feasible in patients with AN. The present review article proposes a practical approach for selecting the most appropriate methods depending on the setting, (i.e. clinical v. research) and the goal of the assessment (initial v. follow-up) in order to have a more personalised treatment for patients suffering from AN.

  15. Implantable microchip transponders for body temperature measurements in pigs

    DEFF Research Database (Denmark)

    Lohse, Louise; Uttenthal, Åse; Enøe, Claes

    thermometer. This work, however, can be quite time consuming and laborious, and further compromising the immediate well-fare of the pig, when restraining of the individual animal is necessary. Therefore, an electronic body monitoring system using implantable microchip transponders for measuring peripheral...... body temperature was tested, in order to evaluate the utility and reliability of this tool, in domestic pigs. The system is presently used and well optimized in small laboratory animals [1, 2]. We tested the microchip transponders during experimental infection of pigs with classical swine fever virus...... microchip transponder was injected deep subcutaneously by the left ear base of each individual. The transponder was before insertion programmed with ID identical to the individual pig’s ear tag number. The pigs were randomly divided into 3 groups: one group placebo-infected and two groups virus...

  16. An Electronic Method for Measuring the Fit of Removable Partial Denture Frameworks to Dental Casts

    Directory of Open Access Journals (Sweden)

    Robert J Williams

    2009-06-01

    Full Text Available It is well established that the Removable Partial Denture (RPD is an effective treatment prosthesis. The objectives of a successful RPD are: to preserve the health of remaining oral structure, restore function and restore esthetics. To achieve these objectives, an RPD framework must fit accurately to the supporting structures. This paper presents a method for measuring the gaps or spaces present between the RPD framework and supporting structures which will enable the dentist and the dental technician to evaluate the accuracy of fitting of the prosthesis before it is delivered to the patient. The method used in this research is based on the principle of electric capacitance and uses a specially designed prototype measurement system.

  17. Measuring mode indices of a partially coherent vortex beam with Hanbury Brown and Twiss type experiment

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ruifeng; Wang, Feiran; Chen, Dongxu; Wang, Yunlong; Zhou, Yu; Gao, Hong; Zhang, Pei, E-mail: zhangpei@mail.ustc.edu.cn; Li, Fuli [Key Laboratory of Quantum Information and Quantum Optoelectronic Devices, Shaanxi Province, Xi' an Jiaotong University, Xi' an 710049 (China)

    2016-02-01

    It is known that the cross-correlation function (CCF) of a partially coherent vortex (PCV) beam shows a robust link with the radial and azimuthal mode indices. However, the previous proposals are difficult to measure the CCF in practical systems, especially in the case of astronomical objects. In this letter, we demonstrate experimentally that the Hanbury Brown and Twiss effect can be used to measure the mode indices of the original vortex beam and investigate the relationship between the spatial coherent width and the characterization of CCF of the PCV beam. The technique we exploit is quite efficient and robust, and it may be useful in the field of free space communication and astronomy which are related to the photon's orbital angular momentum.

  18. Measuring mode indices of a partially coherent vortex beam with Hanbury Brown and Twiss type experiment

    International Nuclear Information System (INIS)

    Liu, Ruifeng; Wang, Feiran; Chen, Dongxu; Wang, Yunlong; Zhou, Yu; Gao, Hong; Zhang, Pei; Li, Fuli

    2016-01-01

    It is known that the cross-correlation function (CCF) of a partially coherent vortex (PCV) beam shows a robust link with the radial and azimuthal mode indices. However, the previous proposals are difficult to measure the CCF in practical systems, especially in the case of astronomical objects. In this letter, we demonstrate experimentally that the Hanbury Brown and Twiss effect can be used to measure the mode indices of the original vortex beam and investigate the relationship between the spatial coherent width and the characterization of CCF of the PCV beam. The technique we exploit is quite efficient and robust, and it may be useful in the field of free space communication and astronomy which are related to the photon's orbital angular momentum

  19. The Impact of Partial Measurement Invariance on Testing Moderation for Single and Multi-Level Data

    Directory of Open Access Journals (Sweden)

    Yu-Yu Hsiao

    2018-05-01

    Full Text Available Moderation effect is a commonly used concept in the field of social and behavioral science. Several studies regarding the implication of moderation effects have been done; however, little is known about how partial measurement invariance influences the properties of tests for moderation effects when categorical moderators were used. Additionally, whether the impact is the same across single and multilevel data is still unknown. Hence, the purpose of the present study is twofold: (a To investigate the performance of the moderation test in single-level studies when measurement invariance does not hold; (b To examine whether unique features of multilevel data, such as intraclass correlation (ICC and number of clusters, influence the effect of measurement non-invariance on the performance of tests for moderation. Simulation results indicated that falsely assuming measurement invariance lead to biased estimates, inflated Type I error rates, and more gain or more loss in power (depends on simulation conditions for the test of moderation effects. Such patterns were more salient as sample size and the number of non-invariant items increase for both single- and multi-level data. With multilevel data, the cluster size seemed to have a larger impact than the number of clusters when falsely assuming measurement invariance in the moderation estimation. ICC was trivially related to the moderation estimates. Overall, when testing moderation effects with categorical moderators, employing a model that accounts for the measurement (noninvariance structure of the predictor and/or the outcome is recommended.

  20. The Impact of Partial Measurement Invariance on Testing Moderation for Single and Multi-Level Data.

    Science.gov (United States)

    Hsiao, Yu-Yu; Lai, Mark H C

    2018-01-01

    Moderation effect is a commonly used concept in the field of social and behavioral science. Several studies regarding the implication of moderation effects have been done; however, little is known about how partial measurement invariance influences the properties of tests for moderation effects when categorical moderators were used. Additionally, whether the impact is the same across single and multilevel data is still unknown. Hence, the purpose of the present study is twofold: (a) To investigate the performance of the moderation test in single-level studies when measurement invariance does not hold; (b) To examine whether unique features of multilevel data, such as intraclass correlation (ICC) and number of clusters, influence the effect of measurement non-invariance on the performance of tests for moderation. Simulation results indicated that falsely assuming measurement invariance lead to biased estimates, inflated Type I error rates, and more gain or more loss in power (depends on simulation conditions) for the test of moderation effects. Such patterns were more salient as sample size and the number of non-invariant items increase for both single- and multi-level data. With multilevel data, the cluster size seemed to have a larger impact than the number of clusters when falsely assuming measurement invariance in the moderation estimation. ICC was trivially related to the moderation estimates. Overall, when testing moderation effects with categorical moderators, employing a model that accounts for the measurement (non)invariance structure of the predictor and/or the outcome is recommended.

  1. Principal components regression of body measurements in five ...

    African Journals Online (AJOL)

    Username, Password, Remember me, or Register ... Body weight and seven biometric traits that are; body length (BL), breast girth (BG), wing length ... Pearson correlations between body weight and biometric traits were positive and highly ...

  2. Optical Signature Analysis of Tumbling Rocket Bodies via Laboratory Measurements

    Science.gov (United States)

    Cowardin, H.; Lederer, S.; Liou, J.-C.

    2012-01-01

    The NASA Orbital Debris Program Office has acquired telescopic lightcurve data on massive intact objects, specifically spent rocket bodies, in order to ascertain tumble rates in support of the Active Debris Removal (ADR) task to help remediate the LEO environment. Rotation rates are needed to plan and develop proximity operations for potential future ADR operations. To better characterize and model optical data acquired from ground-based telescopes, the Optical Measurements Center (OMC) at NASA/JSC emulates illumination conditions in space using equipment and techniques that parallel telescopic observations and source-target-sensor orientations. The OMC employs a 75-watt Xenon arc lamp as a solar simulator, an SBIG CCD camera with standard Johnson/Bessel filters, and a robotic arm to simulate an object's position and rotation. The light source is mounted on a rotary arm, allowing access any phase angle between 0 -- 360 degrees. The OMC does not attempt to replicate the rotation rates, but focuses on how an object is rotating as seen from multiple phase angles. The two targets studied are scaled (1:48), SL-8 Cosmos 3M second stages. The first target is painted in the standard government "gray" scheme and the second target is primary white, as used for commercial missions. This paper summarizes results of the two scaled rocket bodies, each rotated about two primary axes: (a) a spin-stabilized rotation and (b) an end-over-end rotation. The two rotation states are being investigated as a basis for possible spin states of rocket bodies, beginning with simple spin states about the two primary axes. The data will be used to create a database of potential spin states for future works to convolve with more complex spin states. The optical signatures will be presented for specific phase angles for each rocket body and shown in conjunction with acquired optical data from multiple telescope sources.

  3. Method for measuring the stochastic properties of corona and partial-discharge pulses

    International Nuclear Information System (INIS)

    Van Brunt, R.J.; Kulkarni, S.V.

    1989-01-01

    A new method is described for measuring the stochastic behavior of corona and partial-discharge pulses which utilizes a pulse selection and sorting circuit in conjunction with a computer-controlled multichannel analyzer to directly measure various conditional and unconditional pulse-height and pulse-time-separation distributions. From these measured distributions it is possible to determine the degree of correlation between successive discharge pulses. Examples are given of results obtained from measurements on negative, point-to-plane (Trichel-type) corona pulses in a N 2 /O 2 gas mixture which clearly demonstrate that the phenomenon is inherently stochastic in the sense that development of a discharge pulse is significantly affected by the amplitude of and time separation from the preceding pulse. It is found, for example, that corona discharge pulse amplitude and time separation from an earlier pulse are not independent random variables. Discussions are given about the limitations of the method, sources of error, and data analysis procedures required to determine self-consistency of the various measured distributions

  4. Dilatometric measurement of the partial molar volume of water sorbed to durum wheat flour.

    Science.gov (United States)

    Hasegawa, Ayako; Ogawa, Takenobu; Adachi, Shuji

    2013-01-01

    Moisture sorption isotherms were measured at 25 °C for untreated, dry-heated and pre-gelatinized durum wheat flour samples. The isotherms could be expressed by the Guggenheim-Anderson-de Boer equation. The amount of water sorbed to the untreated flour was highest for low water activity, with water sorbed to the pre-gelatinized and dry-heated flour samples following. The dry-heated and pregelatinized flour samples exhibited the same dependence of the moisture content on the partial molar volume of water at 25 °C as the untreated flour. The partial molar volume of water was ca. 9 cm(3)/mol at a moisture content of 0.03 kg-H2O/kg-d.m. The volume increased with increasing moisture content, and reached a constant value of ca. 17.5 cm(3)/mol at a moisture content of 0.2 kg-H2O/kg-d.m. or higher.

  5. General correlation and partial correlation analysis in finding interactions: with Spearman rank correlation and proportion correlation as correlation measures

    OpenAIRE

    WenJun Zhang; Xin Li

    2015-01-01

    Between-taxon interactions can be detected by calculating the sampling data of taxon sample type. In present study, Spearman rank correlation and proportion correlation are chosen as the general correlation measures, and their partial correlations are calculated and compared. The results show that for Spearman rank correlation measure, in all predicted candidate direct interactions by partial correlation, about 16.77% (x, 0-45.4%) of them are not successfully detected by Spearman rank correla...

  6. Measurement of caesium-137 in the human body using a whole body counter

    Science.gov (United States)

    Elessawi, Elkhadra Abdulmula

    Gamma radiation in the environment is mainly due to naturally occurring radionuclides. However, there is also a contribution from anthropogenic radionuclides such as 137Cs which originate from nuclear fission processes. Since 1986, the accident at the Chernobyl power plant has been a significant source of artificial environmental radioactivity. In order to assess the radiological impact of these radionuclides, it is necessary to measure their activities in samples drawn from the environment and in plants and animals including human populations. The whole body counter (WBC) at the University Hospital of Wales in Cardiff makes in vivo measurements of gamma emitting radionuclides using a scanning ring of six large-volume thallium-doped sodium iodide (Nal(Tl)) scintillation detectors. In this work the WBC was upgraded by the addition of two high purity germanium (HPGe) detectors. The performance and suitability of the detection systems were evaluated by comparing the detection limits for Cs. Sensitivities were measured using sources of known activity in a water filled anthropomorphic phantom and theoretical minimum detectable count-rates were estimated from phantom background pulse height spectra. The theoretical minimum detectable activity was about 24 Bq for the combination of six Nal(Tl) detectors whereas for the individual HPGe detectors it was 64 Bq and 65 Bq, despite the much improved energy resolution Activities of 137Cs in the human body between 1993 and 2007 were estimated from the background Nal(Tl) spectra of 813 patients and compared with recent measurements in 14 volunteers. The body burden of Cs in Cardiff patients increased from an average of about 60 Bq in the early and mid 1990s to a maximum of about 100 Bq in 2000. By 2007 it had decreased to about 40 Bq. This latter value was similar to that of Cardiff residents at the time of the Chernobyl accident and to that of the volunteers measured in 2007 (51 Bq). However, it was less than the mean activity of

  7. Concordance of In-Home "Smart" Scale Measurement with Body Weight Measured In-Person.

    Science.gov (United States)

    Ross, Kathryn M; Wing, Rena R

    2016-06-01

    Newer "smart" scales that transmit participants' body weights directly to data collection centers offer the opportunity to simplify weight assessment in weight management research; however, little data exist on the concordance of these data compared to weights measured at in-person assessments. We compared the weights of 58 participants (mean±SD BMI = 31.6±4.8, age = 52.1±9.7 years, 86.2% White, 65.5% Female) measured by study staff at an in-person assessment visit to weights measured on the same day at home using BodyTrace "smart" scales. These measures occurred after 3 months of an internet-based weight management intervention. Weight (mean±SD) measured at the 3-month in-person assessment visit was 81.5±14.7kg compared to 80.4±14.5kg measured on the same day using in-home body weight scales; mean bias =1.1±0.8kg, 95% limits of agreement = -0.5 to 2.6. Two outliers in the data suggest that there may be greater variability between measurements for participants weighing above 110 kg. Results suggest good concordance between the measurements and support the use of the BodyTrace smart scale in weight management research. Future trials using BodyTrace scales for outcome assessment should clearly define protocols for measurement and associated instructions to participants (e.g., instruct individuals to weigh at the same time of day, similarly clothed). Finally, measure concordance should be investigated in a group of individuals weighing more than 110kg.

  8. A lower dimensional feature vector for identification of partial discharges of different origin using time measurements

    International Nuclear Information System (INIS)

    Evagorou, Demetres; Kyprianou, Andreas; Georghiou, George E; Lewin, Paul L; Stavrou, Andreas

    2012-01-01

    Partial discharge (PD) classification into sources of different origin is essential in evaluating the severity of the damage caused by its activity on the insulation of power cables and their accessories. More specifically, some types of PD can be classified as having a detrimental effect on the integrity of the insulation while others can be deemed relatively harmless, rendering the correct classification of different PD types of vital importance to electrical utilities. In this work, a feature vector was proposed based on higher order statistics on selected nodes of the wavelet packet transform (WPT) coefficients of time domain measurements, which can compactly represent the characteristics of different PD sources. To assess its performance, experimental data acquired under laboratory conditions for four different PD sources encountered in power systems were used. The two learning machine methods, namely the support vector machine and the probabilistic neural network, employed as the classification algorithms, achieved overall classification rates of around 98%. In comparison, the utilization of the scaled, raw WPT coefficients as a feature vector resulted in classification accuracy of around 99%, but with a significantly higher number of dimensions (1304 to 16), validating the PD identification ability of the proposed feature. Dimensionality reduction becomes a key factor in online, real-time data collection and processing of PD measurements, reducing the classification effort and the data-storage requirements. Therefore, the proposed method can constitute a potential tool for such online measurements, after addressing issues related to on-site measurements such as the rejection of interference. (paper)

  9. Accuracy of a new partial coherence interferometry analyser for biometric measurements.

    Science.gov (United States)

    Holzer, M P; Mamusa, M; Auffarth, G U

    2009-06-01

    Precise biometry is an essential preoperative measurement for refractive surgery as well as cataract surgery. A new device based on partial coherence interferometry technology was tested and evaluated for accuracy of measurements. In a prospective study 200 eyes of 100 healthy phakic volunteers were examined with a functional prototype of the new ALLEGRO BioGraph (Wavelight AG)/LENSTAR LS 900 (Haag Streit AG) biometer and with the IOLMaster V.5 (Carl Zeiss Meditec AG). As recommended by the manufacturers, repeated measurements were performed with both devices and the results compared using Spearman correlation calculations (WinSTAT). Spearman correlation showed high correlations for axial length and keratometry measurements between the two devices tested. Anterior chamber depth, however, had a lower correlation between the two biometry devices. In addition, the mean values of the anterior chamber depth differed (IOLMaster 3.48 (SD 0.42) mm versus BioGraph/LENSTAR 3.64 (SD 0.26) mm); however, this difference was not statistically different (p>0.05, t test). The new biometer provided results that correlated very well with those of the IOLMaster. The ALLEGRO BioGraph/LENSTAR LS 900 is a precise device containing additional features that will be helpful tools for any cataract or refractive surgeon.

  10. Measuring Parameters of Massive Black Hole Binaries with Partially Aligned Spins

    Science.gov (United States)

    Lang, Ryan N.; Hughes, Scott A.; Cornish, Neil J.

    2011-01-01

    The future space-based gravitational wave detector LISA will be able to measure parameters of coalescing massive black hole binaries, often to extremely high accuracy. Previous work has demonstrated that the black hole spins can have a strong impact on the accuracy of parameter measurement. Relativistic spin-induced precession modulates the waveform in a manner which can break degeneracies between parameters, in principle significantly improving how well they are measured. Recent studies have indicated, however, that spin precession may be weak for an important subset of astrophysical binary black holes: those in which the spins are aligned due to interactions with gas. In this paper, we examine how well a binary's parameters can be measured when its spins are partially aligned and compare results using waveforms that include higher post-Newtonian harmonics to those that are truncated at leading quadrupole order. We find that the weakened precession can substantially degrade parameter estimation, particularly for the "extrinsic" parameters sky position and distance. Absent higher harmonics, LISA typically localizes the sky position of a nearly aligned binary about an order of magnitude less accurately than one for which the spin orientations are random. Our knowledge of a source's sky position will thus be worst for the gas-rich systems which are most likely to produce electromagnetic counterparts. Fortunately, higher harmonics of the waveform can make up for this degradation. By including harmonics beyond the quadrupole in our waveform model, we find that the accuracy with which most of the binary's parameters are measured can be substantially improved. In some cases, the improvement is such that they are measured almost as well as when the binary spins are randomly aligned.

  11. Measurement of whole body cellular and collagen nitrogen, potassium, and other elements by neutron activation and whole body counting

    International Nuclear Information System (INIS)

    James, H.M.; Fabricius, P.J.; Dykes, P.W.

    1987-01-01

    Whole body nitrogen can be measured by neutron activation analysis with an acceptable radiation dose; it is an index of body protein which, in normal subjects, is 65% cellular protein and 35% extracellular connective collagen. Whole body potassium can be measured by whole body counting without irradiating the subject; it is an index of body cell mass. We measured whole body nitrogen, potassium, extracellular water, intracellular water, and fat-folds. The differences between 37 malnourished patients and five normal subjects suggested that the patients had 9 kg less cell mass than normal, but no difference in extracellular mass. Measurements were made on eight patients before and after 14 days of total parenteral nutrition; balance of nitrogen intake and excretion also was measured. The changes were consistent with mean increases of 3 kg of cellular mass and 3 kg of fat with no change of extracellular mass. The accuracy and sensitivity of the whole body measurements need further confirmation for use in patients with changing body composition. Where tissue wasting is largely from the cellular compartment, potassium could be a more sensitive index of wasting than nitrogen. Multielement analysis of nitrogen, potassium, chlorine, and carbon will probably be valuable in elucidating body composition in malnutrition

  12. Comparative analysis of speed's impact on muscle demands during partial body weight support motor-assisted elliptical training.

    Science.gov (United States)

    Burnfield, Judith M; Irons, Sonya L; Buster, Thad W; Taylor, Adam P; Hildner, Gretchen A; Shu, Yu

    2014-01-01

    Individuals with walking limitations often experience challenges engaging in functionally relevant exercise. An adapted elliptical trainer (motor to assist pedal movement, integrated body weight harness, ramps/stairs, and grab rails) has been developed to help individuals with physical disabilities and chronic conditions regain/retain walking capacity and fitness. However, limited published studies are available to guide therapeutic interventions. This repeated measures study examined the influence of motor-assisted elliptical training speed on lower extremity muscle demands at four body weight support (BWS) levels commonly used therapeutically for walking. Electromyography (EMG) and pedal trajectory data were recorded as ten individuals without known disability used the motor-assisted elliptical trainer at three speeds [20,40, 60 revolutions per minute (RPM)] during each BWS level (0%, 20%, 40%, 60%). Overall, the EMG activity (peak, mean, duration) in key stabilizer muscles (i.e., gluteus medius, gluteus maximus, vastus lateralis, medial gastrocnemius and soleus) recorded at 60 RPM exceeded those at 40 RPM, which were higher than values at 20 RPM in all but three situations (gluteus medius mean at 0% BWS, vastus lateralis mean at 20% BWS, soleus duration at 40% BWS); however, these differences did not always achieve statistical significance. Slower motor-assisted speeds can be used to accommodate weakness of gluteus medius, gluteus maximus, vastus lateralis, medial gastrocnemius and soleus. As strength improves, training at faster motor-assisted speeds may provide a means to progressively challenge key lower extremity stabilizers. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Association between different phases of menstrual cycle and body image measures of perceived size, ideal size, and body dissatisfaction.

    Science.gov (United States)

    Teixeira, André Luiz S; Dias, Marcelo Ricardo C; Damasceno, Vinícius O; Lamounier, Joel A; Gardner, Rick M

    2013-12-01

    The association between phases of the menstrual cycle and body image was investigated. 44 university women (M age = 23.3 yr., SD = 4.7) judged their perceived and ideal body size, and body dissatisfaction was calculated at each phase of the menstrual cycle, including premenstrual, menstrual, and intermenstrual. Participants selected one of nine figural drawings ranging from very thin to obese that represented their perceived size and ideal size. Body dissatisfaction was measured as the absolute difference between scores on perceived and ideal figural drawings. During each menstrual phase, anthropometric measures of weight, height, body mass index, circumference of waist and abdomen, and body composition were taken. There were no significant differences in any anthropometric measures between the three menstrual cycle phases. Perceived body size and body dissatisfaction were significantly different between menstrual phases, with the largest perceived body size and highest body dissatisfaction occurring during the menstrual phase. Ideal body size did not differ between menstrual phases, although participants desired a significantly smaller ideal size as compared to the perceived size.

  14. Methodological aspects of EEG and Body dynamics measurements during motion.

    Directory of Open Access Journals (Sweden)

    Pedro eReis

    2014-03-01

    Full Text Available EEG involves recording, analysis, and interpretation of voltages recorded on the human scalp originating from brain grey matter. EEG is one of the favorite methods to study and understand processes that underlie behavior. This is so, because EEG is relatively cheap, easy to wear, light weight and has high temporal resolution. In terms of behavior, this encompasses actions, such as movements, that are performed in response to the environment. However, there are methodological difficulties when recording EEG during movement such as movement artifacts. Thus, most studies about the human brain have examined activations during static conditions. This article attempts to compile and describe relevant methodological solutions that emerged in order to measure body and brain dynamics during motion. These descriptions cover suggestions of how to avoid and reduce motion artifacts, hardware, software and techniques for synchronously recording EEG, EMG, kinematics, kinetics and eye movements during motion. Additionally, we present various recording systems, EEG electrodes, caps and methods for determination of real/custom electrode positions. In the end we will conclude that it is possible to record and analyze synchronized brain and body dynamics related to movement or exercise tasks.

  15. Individualized estimation of human core body temperature using noninvasive measurements.

    Science.gov (United States)

    Laxminarayan, Srinivas; Rakesh, Vineet; Oyama, Tatsuya; Kazman, Josh B; Yanovich, Ran; Ketko, Itay; Epstein, Yoram; Morrison, Shawnda; Reifman, Jaques

    2018-06-01

    A rising core body temperature (T c ) during strenuous physical activity is a leading indicator of heat-injury risk. Hence, a system that can estimate T c in real time and provide early warning of an impending temperature rise may enable proactive interventions to reduce the risk of heat injuries. However, real-time field assessment of T c requires impractical invasive technologies. To address this problem, we developed a mathematical model that describes the relationships between T c and noninvasive measurements of an individual's physical activity, heart rate, and skin temperature, and two environmental variables (ambient temperature and relative humidity). A Kalman filter adapts the model parameters to each individual and provides real-time personalized T c estimates. Using data from three distinct studies, comprising 166 subjects who performed treadmill and cycle ergometer tasks under different experimental conditions, we assessed model performance via the root mean squared error (RMSE). The individualized model yielded an overall average RMSE of 0.33 (SD = 0.18)°C, allowing us to reach the same conclusions in each study as those obtained using the T c measurements. Furthermore, for 22 unique subjects whose T c exceeded 38.5°C, a potential lower T c limit of clinical relevance, the average RMSE decreased to 0.25 (SD = 0.20)°C. Importantly, these results remained robust in the presence of simulated real-world operational conditions, yielding no more than 16% worse RMSEs when measurements were missing (40%) or laden with added noise. Hence, the individualized model provides a practical means to develop an early warning system for reducing heat-injury risk. NEW & NOTEWORTHY A model that uses an individual's noninvasive measurements and environmental variables can continually "learn" the individual's heat-stress response by automatically adapting the model parameters on the fly to provide real-time individualized core body temperature estimates. This

  16. A Data-Driven Response Virtual Sensor Technique with Partial Vibration Measurements Using Convolutional Neural Network

    Science.gov (United States)

    Sun, Shan-Bin; He, Yuan-Yuan; Zhou, Si-Da; Yue, Zhen-Jiang

    2017-01-01

    Measurement of dynamic responses plays an important role in structural health monitoring, damage detection and other fields of research. However, in aerospace engineering, the physical sensors are limited in the operational conditions of spacecraft, due to the severe environment in outer space. This paper proposes a virtual sensor model with partial vibration measurements using a convolutional neural network. The transmissibility function is employed as prior knowledge. A four-layer neural network with two convolutional layers, one fully connected layer, and an output layer is proposed as the predicting model. Numerical examples of two different structural dynamic systems demonstrate the performance of the proposed approach. The excellence of the novel technique is further indicated using a simply supported beam experiment comparing to a modal-model-based virtual sensor, which uses modal parameters, such as mode shapes, for estimating the responses of the faulty sensors. The results show that the presented data-driven response virtual sensor technique can predict structural response with high accuracy. PMID:29231868

  17. A Data-Driven Response Virtual Sensor Technique with Partial Vibration Measurements Using Convolutional Neural Network.

    Science.gov (United States)

    Sun, Shan-Bin; He, Yuan-Yuan; Zhou, Si-Da; Yue, Zhen-Jiang

    2017-12-12

    Measurement of dynamic responses plays an important role in structural health monitoring, damage detection and other fields of research. However, in aerospace engineering, the physical sensors are limited in the operational conditions of spacecraft, due to the severe environment in outer space. This paper proposes a virtual sensor model with partial vibration measurements using a convolutional neural network. The transmissibility function is employed as prior knowledge. A four-layer neural network with two convolutional layers, one fully connected layer, and an output layer is proposed as the predicting model. Numerical examples of two different structural dynamic systems demonstrate the performance of the proposed approach. The excellence of the novel technique is further indicated using a simply supported beam experiment comparing to a modal-model-based virtual sensor, which uses modal parameters, such as mode shapes, for estimating the responses of the faulty sensors. The results show that the presented data-driven response virtual sensor technique can predict structural response with high accuracy.

  18. Comparison of anterior segment measurements using rotating Scheimpflug imaging and partial coherence interferometry

    Directory of Open Access Journals (Sweden)

    Akbar Fotouhi

    2013-08-01

    Full Text Available METHODS:As part of the first phase of Shahroud Eye Cohort Study with 5 190 subjects of 40 to 64 years of age, CCT and ACD were measured using Scheimpflug imaging with the Pentacam (Oculus, Inc., Lynnwood, WA, USA and partial coherence interferometry with the Allegro BioGraph (Wavelight, Erlangen, Germany.RESULTS:After applying exclusion criteria, we had data of 4 387 subjects with a mean age of 50.7±6.2 years. Mean CCT with Pentacam and BioGraph were 528.6±33.2μm and 525.6±32μm respectively; the difference was statistically significant (PPCONCLUSION:For both CCT and ACD, the BioGraph gave significantly lower values than the Pentacam (P<0.05. Despite the high inter-device correlation, the 95% limits of agreements were wide, and this may limit their interchangeability in measuring the CCT and ACD.

  19. Effects of Whole and Partial Body Exposure to Dry Heat on Certain Performance Measures.

    Science.gov (United States)

    1981-05-01

    Robert Bachert who assisted with the statistical analyses; and he acknowledges the support of the Lite Mr. George C. Frost for his advice on the...of the study and interpretation of data: Dr. Arthur L Dudycha, Dr. Barry H. Kantowitz, Dr. N. M. Downie, Dr. Ernest J. McCormick, and Dr. Robert D...D., Summers, W. C., & Smedley , D. C., November 1974, Evaluation of a water- cooled helmet liner (AMRL-TR-74-135). Aerospace Medical Research

  20. Partial body weight support treadmill training speed influences paretic and non-paretic leg muscle activation, stride characteristics, and ratings of perceived exertion during acute stroke rehabilitation.

    Science.gov (United States)

    Burnfield, Judith M; Buster, Thad W; Goldman, Amy J; Corbridge, Laura M; Harper-Hanigan, Kellee

    2016-06-01

    Intensive task-specific training is promoted as one approach for facilitating neural plastic brain changes and associated motor behavior gains following neurologic injury. Partial body weight support treadmill training (PBWSTT), is one task-specific approach frequently used to improve walking during the acute period of stroke recovery (training parameters and physiologic demands during this early recovery phase. To examine the impact of four walking speeds on stride characteristics, lower extremity muscle demands (both paretic and non-paretic), Borg ratings of perceived exertion (RPE), and blood pressure. A prospective, repeated measures design was used. Ten inpatients post unilateral stroke participated. Following three familiarization sessions, participants engaged in PBWSTT at four predetermined speeds (0.5, 1.0, 1.5 and 2.0mph) while bilateral electromyographic and stride characteristic data were recorded. RPE was evaluated immediately following each trial. Stride length, cadence, and paretic single limb support increased with faster walking speeds (p⩽0.001), while non-paretic single limb support remained nearly constant. Faster walking resulted in greater peak and mean muscle activation in the paretic medial hamstrings, vastus lateralis and medial gastrocnemius, and non-paretic medial gastrocnemius (p⩽0.001). RPE also was greatest at the fastest compared to two slowest speeds (ptraining at the slowest speeds. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Acoustic position finding of partial discharges in transformers. Combination of partial discharge measurement technology with 3D visualization; Akustische Ortung von Teilentladungen in Transformatoren. TE-Messtechnik und 3-D-Visualisierung kombiniert

    Energy Technology Data Exchange (ETDEWEB)

    Kraetge, Alexander; Hoek, Stefan [Omicron Electronics GmbH, Klaus (Austria)

    2013-11-01

    A new measuring system facilitates the detection of partial discharges in transformers by means of the fully synchronous combination of measurement technology for electrical partial discharges with intuitive 3D visualization of the test object. The contribution under consideration describes the application of this system with examples from the measurement practice.

  2. Effects of dose and of partial body ionizing radiation on taste aversion learning in rats with lesions of the area postrema

    International Nuclear Information System (INIS)

    Rabin, B.M.; Hunt, W.A.; Lee, J.

    1984-01-01

    The effect of area postrema lesions on the acquisition of a conditioned taste aversion following partial body exposure to ionizing radiation was investigated in rats exposed to head-only irradiation at 100, 200 and 300 rad or to body-only irradiation at 100 and 200 rad. Following head-only irradiation area postrema lesions produced a significant attenuation of the radiation-induced taste aversion at all dose levels, although the rats still showed a significant reduction in sucrose preference. Following body-only exposure, area postrema lesions completely disrupted the acquisition of the conditioned taste aversion. The results are interpreted as indicating that: (a) the acquisition of a conditioned taste aversion following body-only exposure is mediated by the area postrema; and (b) taste aversion learning following radiation exposure to the head-only is mediated by both the area postrema and a mechanism which is independent of the area postrema

  3. Whole body measurements for in vivo monitoring in emergency situations

    International Nuclear Information System (INIS)

    Doerfel, H.

    2000-01-01

    The conventional procedures for in vivo monitoring of γ-emitting radionuclides require a lot of information, such as time and pathway of intake, physical and chemical form of incorporated materials, metabolism etc. In emergency situations this information is rarely available, thus resulting in significant uncertainties for the estimation of intake and committed dose equivalent. Moreover, the procedure is time consuming and thus only a relatively small number of persons can be monitored. In order to cope with these difficulties, a new method for direct internal dosimetry has recently been developed at Karlsruhe Nuclear Research Centre. The method is based on the measurement of the integral photon flux emitted from the body using a special detector system which has been optimised in such a way that the system sensitivity matches the respective dose factors for a maximum number of radionuclides and deposition sites in the body. The detector system consists of four plastic scintillation detectors, which are positioned at the thyroid, at the lungs, under the gastro-intestinal tract and over the thighs of the person monitored in a seated posture. The system allows for detection of effective dose equivalent rates down to 1.6 μSv/week, the mean detection uncertainty being about 200% for known radionuclide mixtures and about 600% for unknown radionuclide mixtures, respectively. The detector system is very easy to handle; the measurement can be performed by untrained individuals and the results are available after a very short measuring time (20 s). Thus, the detector system is appropriate especially for short-term decision making after incidents or accidents. Because of its relative low weight (1 t) the detector system could be installed as a mobile unit in a container for transportation by car, train or aircraft. Thus, in emergency situations the detector system can be brought to the site within a short period of time. It allows for the rapid monitoring of a large number

  4. Optical Signature Analysis of Tumbling Rocket Bodies via Laboratory Measurements

    Science.gov (United States)

    Cowardin, H.; Lederer, S.; Liou, J.-C.; Ojakangas, G.; Mulrooney, M.

    2012-09-01

    The NASA Orbital Debris Program Office has acquired telescopic lightcurve data on massive intact objects, specifically spent rocket bodies (R/Bs), to ascertain tumble rates in support of the Active Debris Removal (ADR) studies to help remediate the LEO environment. Tumble rates are needed to plan and develop proximity and docking operations for potential future ADR operations. To better characterize and model optical data acquired from ground-based telescopes, the Optical Measurements Center (OMC) at NASA/JSC emulates illumination conditions in space using equipment and techniques that parallel telescopic observations and source-target-sensor orientations. The OMC employs a 75-W Xenon arc lamp as a solar simulator, an SBIG CCD camera with standard Johnson/Bessel filters, and a robotic arm to simulate an object's position and rotation. The OMC does not attempt to replicate the rotation rates, but focuses on ascertaining how an object is rotating as seen from multiple phase angles. The two targets studied are scaled (1:48) SL-8 Cosmos 3M second stages. The first target is painted in the standard Russian government "gray" scheme and the second target is white/orange as used for commercial missions. This paper summarizes results of the two scaled rocket bodies, each observed in three independent rotation states: (a) spin-stabilized rotation (about the long axis), (b) end-over-end rotation, and (c) a 10 degree wobble about the center of mass. The first two cases represent simple spin about either primary axis. The third - what we call "wobble" - represents maximum principal axis rotation, with an inertia tensor that is offset from the symmetry axes. By comparing the resultant phase and orientation-dependent laboratory signatures with actual lightcurves derived from telescopic observations of orbiting R/Bs, we intend to assess the intrinsic R/B rotation states. In the simplest case, simulated R/B behavior coincides with principal axis spin states, while more complex R

  5. An Extension of the Partial Credit Model with an Application to the Measurement of Change.

    Science.gov (United States)

    Fischer, Gerhard H.; Ponocny, Ivo

    1994-01-01

    An extension to the partial credit model, the linear partial credit model, is considered under the assumption of a certain linear decomposition of the item x category parameters into basic parameters. A conditional maximum likelihood algorithm for estimating basic parameters is presented and illustrated with simulation and an empirical study. (SLD)

  6. Development of a Force Measurement Device for Lower-Body Muscular Strength Measuring of Skaters

    Science.gov (United States)

    Kim, Dong Ki; Lee, Jeong Tae

    This paper presents a force measurement system that can measure a lower-body muscular strength of skaters. The precise measurement and analysis of the left and right lower-body strength of skaters is necessary, because a left/right lower-body strength balance is helpful to improve the athletes' performance and to protect them from injury. The system is constructed with a skate sliding board, a couple of sensor-units with load cell, indicator and control box, guard, force pad, and support bracket. The developed force measurement system is calibrated by the calibration setup, and the uncertainty of the force sensing unit on the left is within 0.087% and the uncertainty of the force sensing unit on the right is within 0.109%. In order to check the feasibility of the developed measurement device, a kinematic analysis is conducted with skater. As a result, the subject shows the deviation of left and right of 12.1 N with respect to average strength and 39.1 N with respect to the maximum strength. This evaluation results are reliable enough to make it possible to measure a lower-body muscular strength of skaters. The use of this measurement system will be expected to correct the posture of skaters and record the sports dynamics data for each athlete. It is believed that through the development of this equipment, skaters in elementary, middle, high schools, colleges, and the professional level have the systematic training to compete with world-class skaters.

  7. Effects of conventional overground gait training and a gait trainer with partial body weight support on spatiotemporal gait parameters of patients after stroke

    OpenAIRE

    Park, Byoung-Sun; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Noh, Ji-Woong; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Kim, Junghwan

    2015-01-01

    [Purpose] The purpose of this study was to confirm the effects of both conventional overground gait training (CGT) and a gait trainer with partial body weight support (GTBWS) on spatiotemporal gait parameters of patients with hemiparesis following chronic stroke. [Subjects and Methods] Thirty stroke patients were alternately assigned to one of two treatment groups, and both groups underwent CGT and GTBWS. [Results] The functional ambulation classification on the affected side improved signifi...

  8. Measurement of Online Student Engagement: Utilization of Continuous Online Student Behavior Indicators as Items in a Partial Credit Rasch Model

    Science.gov (United States)

    Anderson, Elizabeth

    2017-01-01

    Student engagement has been shown to be essential to the development of research-based best practices for K-12 education. It has been defined and measured in numerous ways. The purpose of this research study was to develop a measure of online student engagement for grades 3 through 8 using a partial credit Rasch model and validate the measure…

  9. Forming positive-negative images using conditioned partial measurements from reference arm in ghost imaging.

    Science.gov (United States)

    Wen, Jianming

    2012-09-01

    A recent thermal ghost imaging experiment implemented in Wu's group [Chin. Phys. Lett. 279, 074216 (2012)] showed that both positive and negative images can be constructed by applying a novel algorithm. This algorithm allows us to form the images with the use of partial measurements from the reference arm (even which never passes through the object), conditioned on the object arm. In this paper, we present a simple theory that explains the experimental observation and provides an in-depth understanding of conventional ghost imaging. In particular, we theoretically show that the visibility of formed images through such an algorithm is not bounded by the standard value 1/3. In fact, it can ideally grow up to unity (with reduced imaging quality). Thus, the algorithm described here not only offers an alternative way to decode spatial correlation of thermal light, but also mimics a "bandpass filter" to remove the constant background such that the visibility or imaging contrast is improved. We further show that conditioned on one still object present in the test arm, it is possible to construct the object's image by sampling the available reference data.

  10. Reinforcement learning for partially observable dynamic processes: adaptive dynamic programming using measured output data.

    Science.gov (United States)

    Lewis, F L; Vamvoudakis, Kyriakos G

    2011-02-01

    Approximate dynamic programming (ADP) is a class of reinforcement learning methods that have shown their importance in a variety of applications, including feedback control of dynamical systems. ADP generally requires full information about the system internal states, which is usually not available in practical situations. In this paper, we show how to implement ADP methods using only measured input/output data from the system. Linear dynamical systems with deterministic behavior are considered herein, which are systems of great interest in the control system community. In control system theory, these types of methods are referred to as output feedback (OPFB). The stochastic equivalent of the systems dealt with in this paper is a class of partially observable Markov decision processes. We develop both policy iteration and value iteration algorithms that converge to an optimal controller that requires only OPFB. It is shown that, similar to Q -learning, the new methods have the important advantage that knowledge of the system dynamics is not needed for the implementation of these learning algorithms or for the OPFB control. Only the order of the system, as well as an upper bound on its "observability index," must be known. The learned OPFB controller is in the form of a polynomial autoregressive moving-average controller that has equivalent performance with the optimal state variable feedback gain.

  11. Performance Characteristics and Prediction of Bodyweight using Linear Body Measurements in Four Strains of Broiler Chicken

    OpenAIRE

    I. Udeh; J.O. Isikwenu and G. Ukughere

    2011-01-01

    The objectives of this study were to compare the performance characteristics of four strains of broiler chicken from 2 to 8 weeks of age and predict body weight of the broilers using linear body measurements. The four strains of broiler chicken used were Anak, Arbor Acre, Ross and Marshall. The parameters recorded were bodyweight, weight gain, total feed intake, feed conversion ratio, mortality and some linear body measurements (body length, body width, breast width, drumstick length, shank l...

  12. Microchip-based body temperature measurements in pigs

    DEFF Research Database (Denmark)

    Nielsen, Jens; Lohse, Louise

    In the present study, we tested whether an electronic identification and body temperature monitorring technology presently applied in small experimental animals could be transferred for use in pigs....

  13. Dose monitoring in Partial Liquid Ventilation by infrared measurement of expired perfluorochemicals.

    Science.gov (United States)

    Mazzoni, M; Nugent, L; Klein, D; Hoffman, J; Sekins, K M; Flaim, S F

    1999-01-01

    Patients undergoing Partial Liquid Ventilation (PLV) with the perfluorochemical liquid perflubron (PFB) continuously evaporate the drug from the lung during ventilatory expiration. In this study, two infrared (IR) devices, a modified industrial analyzer ("experimental prototype") and a custom-designed device suitable for use in a clinical environment ("clinical prototype"), were calibrated and validated on the bench to measure a range of PFB concentrations (CPFB) in a gas stream. PFB loss from the lung (area under the CPFB-vs-time-curve) could be correlated during PLV simulation with changes in tidal volume, breathing rate, and variable CPFB-vs-time profiles. The two IR devices produced nearly identical measurements for the same CPFB standards (maximum deviation = 1.5%). The experimental IR prototype was tested in 17 anesthetized, paralyzed, and ventilated swine (42-53 kg) to quantify the total amount and rate of evaporate loss of PFB over 12 hours of PLV, both with and without periodic supplemental PFB doses. The residual PFB volumes in the animal lungs at the end of the study, as determined by a gravimetric postmortem lung method, were found to agree on average for all animals to within 10% of the residual PFB volume as predicted by the IR approach. Furthermore, the IR signal of CPFB does not appear to correlate with the absolute amount of PFB in the lungs, but may reflect the relative proportion of PFB-wetted airway and alveolar surface. The authors conclude that IR quantitation of PFB evaporative loss is acceptably accurate for extended periods of PLV and may be a useful tool in the clinic for PFB dose monitoring and maintenance, thereby helping to optimize PLV treatment.

  14. Direct methods for measuring radionuclides in the human body

    International Nuclear Information System (INIS)

    1996-01-01

    Occupational exposure leading to intakes of internally incorporated radionuclides can occur as a result of various activities. This includes work associated with the different stages of the nuclear fuel cycle, the use of radioactive sources in medicine, scientific research, agriculture and industry, and occupations which involve exposure to enhanced levels of naturally occurring radionuclides. In 1987 the IAEA published a Safety Guide on basic principles for occupational radiation monitoring which set forth principles and objectives of a strategy for monitoring exposures of workers. Since drafting of the present Safety Practice commenced, the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS) have been issued. On the basis of the principles laid down in the BSS, the 1987 Safety Guide is also being revised, and recommendations on the assessment of the occupational intake of radioactive materials are to be added. The present Safety Practice, which deals with direct measurement of radionuclides in the human body, is the first to be published in this area. Refs, figs, tabs

  15. Treadmill training with partial body weight support and an electromechanical gait trainer for restoration of gait in subacute stroke patients: a randomized crossover study.

    Science.gov (United States)

    Werner, C; Von Frankenberg, S; Treig, T; Konrad, M; Hesse, S

    2002-12-01

    The purpose of this study was to compare treadmill and electromechanical gait trainer therapy in subacute, nonambulatory stroke survivors. The gait trainer was designed to provide nonambulatory subjects the repetitive practice of a gait-like movement without overexerting therapists. This was a randomized, controlled study with a crossover design following an A-B-A versus a B-A-B pattern. A consisted of 2 weeks of gait trainer therapy, and B consisted of 2 weeks of treadmill therapy. Thirty nonambulatory hemiparetic patients, 4 to 12 weeks after stroke, were randomly assigned to 1 of the 2 groups receiving locomotor therapy every workday for 15 to 20 minutes for 6 weeks. Weekly gait ability (functional ambulation category [FAC]), gait velocity, and the required physical assistance during both kinds of locomotor therapy were the primary outcome measures, and other motor functions (Rivermead motor assessment score) and ankle spasticity (modified Ashworth score) were the secondary outcome measures. Follow-up occurred 6 months later. The groups did not differ at study onset with respect to the clinical characteristics and effector variables. During treatment, the FAC, gait velocity, and Rivermead scores improved in both groups, and ankle spasticity did not change. Median FAC level was 4 (3 to 4) in group A compared with 3 (2 to 3) in group B at the end of treatment (P=0.018), but the difference at 6-month follow up was not significant. The therapeutic effort was less on the gait trainer, with 1 instead of 2 therapists assisting the patient at study onset. All but seven patients preferred the gait trainer. The newly developed gait trainer was at least as effective as treadmill therapy with partial body weight support while requiring less input from the therapist. Further studies are warranted.

  16. Nasonia Parasitic Wasps Escape from Haller's Rule by Diphasic, Partially Isometric Brain-Body Size Scaling and Selective Neuropil Adaptations

    NARCIS (Netherlands)

    Groothuis, Jitte; Smid, Hans M.

    2017-01-01

    Haller's rule states that brains scale allometrically with body size in all animals, meaning that relative brain size increases with decreasing body size. This rule applies both on inter- and intraspecific comparisons. Only 1 species, the extremely small parasitic wasp Trichogramma evanescens, is

  17. changes in body composition and other anthropometric measures of ...

    African Journals Online (AJOL)

    This study aimed to investigate the changes in body composition and other anthropometric .... showing a good fit between the values obtained from the equation ..... ideally at 6-monthly intervals, in order to provide useful information to ... training on quality of life in HAART-treated HIV-positive Rwandan subjects with body fat ...

  18. Investigation into the relationship between body surface area and total body potassium using Monte Carlo and measurement

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, J.A. [Medical Physics and Imaging, Queen Elizabeth Hospital, Birmingham (United Kingdom)]. E-mail: jane.rogers@university-b.wmids.nhs.uk; Blake-James, M. [School of Physics and Astronomy, University of Birmingham, Birmingham (United Kingdom); Green, S.; Beddoe, A.H. [Medical Physics and Imaging, Queen Elizabeth Hospital, Birmingham (United Kingdom)

    2002-03-07

    The use of body surface area (BSA) as a means of indexing chemotherapy doses is widespread even though the value of this practice is uncertain. In principle, the body cell mass (BCM) more closely represents the body's metabolic size and this is investigated here as an alternative to BSA; since 98% of body potassium is intracellular the derivation of total body potassium (TBK) via the measurement of {sup 40}K in a whole body counter (WBC) will provide a useful normalizing index for metabolic size, potentially avoiding toxicity and underdosing. The Queen Elizabeth Hospital WBC has been used in this study, initially involving single geometrical phantoms and then combinations of these to simulate human body habitus. Monte Carlo N-particle (MCNP) codes were constructed to model the phantoms and simulate the measurements made in the WBC. Efficiency corrections were derived by comparing measurement and modelled data for each detector separately. A method of modelling a person in the WBC as a series of ellipsoids was developed. Twenty-four normal males and 24 females were measured for their {sup 40}K emissions. Individual MCNP codes were constructed for each volunteer and the results used in conjunction with the measurements to derive TBK, correcting for body habitus effects and detector efficiencies. An estimate of the component of error arising from sources other than counting statistics was included by analysing data from the measurement of phantoms. The total residual errors (expressed as coefficients of variation) for males and females were 10.1% and 8.5% respectively. The measurement components were determined to be 2.4% and 2.5%, implying that the biological components were 9.8% and 8.1% respectively. These results suggest that the use of BSA for indexing chemotherapy doses is likely to give rise to clinically significant under- or overdosing. (author)

  19. Scan posture definition and hip girth measurement: the impact on clothing design and body scanning.

    Science.gov (United States)

    Gill, Simeon; Parker, Christopher J

    2017-08-01

    Ergonomic measurement is central to product design and development; especially for body worn products and clothing. However, there is a large variation in measurement definitions, complicated by new body scanning technology that captures measurements in a posture different to traditional manual methods. Investigations of hip measurement definitions in current clothing measurement practices supports analysis of the effect of scan posture and hip measurement definition on the circumferences of the hip. Here, the hip girth is a key clothing measurement that is not defined in current body scanning measurement standards. Sixty-four participants were scanned in the standard scan posture of a [TC] 2 body scanner, and also in a natural posture similar to that of traditional manual measurement collection. Results indicate that scan posture affects hip girth circumferences, and that some current clothing measurement practices may not define the largest lower body circumference. Recommendations are made concerning how the hip is defined in measurement practice and within body scanning for clothing product development. Practitioner Summary: The hip girth is an important measurement in garment design, yet its measurement protocol is not currently defined. We demonstrate that body posture during body scanning affects hip circumferences, and that current clothing measurement practices may not define the largest lower body circumference. This paper also provides future measurement practice recommendations.

  20. Whole-body counter intercomparison measurements in Hungary and Italy

    Energy Technology Data Exchange (ETDEWEB)

    Andrasi, A. [Atomic Energy Research Institute, Budapest (Hungary). KFKI; Tarroni, G. [ENEA, Centro Ricerche `Ezio Clementel`, Bologna (Italy). Dipt. Ambiente

    1999-01-01

    In the frame of a co-operation agreement between Austrian Research Center Seibersdorf, Italian ENEA Institute for Radiation Protection and Hungarian KFKI Atomic Energy Research Centre, an intercomparison on WBC measurements using a modular bottle phantom was performed during 1995 in Hungary, on May-July 1996 in the Northern part of Italy. Results related to the relative bias for the three body masses are reported, together with indication of their compliance with ANSI report N13.30. It turned out that majority of the results were found to be within the performance criteria of the ANSI report, however there were also few outfalling results which were a good indication to check and improve the reliability of calibration and/or other methodological procedures. In the contrary of the expectance, the results related to 20 kg phantom resulted not significantly worse than those obtained for the adult phantom indicating the capacity for the participating WBC centres of measuring people from the general population. [Italiano] Nell`ambito di un accordo di collaborazione tra il Centro di Ricerca di Seibersdorf (Austria), l`Istituto per la Radioprotezione dell`ENEA (ENEA AMB PRO IRP) ed il Centro di Ricerca per l`Energia Atomica KFKI di Budapest (Ungheria), si e` svolto un interconfronto su misure WBC basato sull`utilizzo di un unico fantoccio modulare a bottiglie cui hanno partecipato centri WBC Ungheresi (1995) ed Italiani (Maggio-Giugno 1996). Nel presente rapporto tecnico vengono presentati i risultati ottenuti ed una loro analisi impostata sui criteri di valutazione recentemente proposti dall`ANSI nel rapporto N. 13.30. Sulla base di tale criterio la maggior parte dei risultati dell`interconfronto rientra nell`intervallo di accettabilita`; nei pochi casi di non accettabilita` si rende invece necessaria una revisione dei dati di calibrazione e delle metodologie. Contrariamente a quanto si poteva prevedere, i risultati relativi al fantoccio da 20 kg appaiono sostanzialmente

  1. Using path analysis to predict bodyweight from body measurements ...

    African Journals Online (AJOL)

    Esnart Mukumbo

    2017-10-05

    Oct 5, 2017 ... South African Journal of Animal Science 2017, 47 (No. 6) .... Some farmers kept Dorper and Karakul sheep, while others kept Boer, Savannah and ..... body weight and biometric traits of red Sokoto goats in northern Nigeria.

  2. SU-E-I-59: Image Quality and Dose Measurement for Partial Cone-Beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Abouei, E; Ford, N [University of British Columbia, Vancouver, BC (Canada)

    2014-06-01

    Purpose: To characterize performance of cone beam CT (CBCT) used in dentistry investigating quantitatively the image quality and radiation dose during dental CBCT over different settings for partial rotation of the x-ray tube. Methods: Image quality and dose measurements were done on a variable field of view (FOV) dental CBCT (Carestream 9300). X-ray parameters for clinical settings were adjustable for 2–10 mA, 60–90 kVp, and two optional voxel size values, but time was fixed for each FOV. Image quality was assessed by scanning cylindrical poly-methyl methacrylate (PMMA) image quality phantom (SEDENTEXCT IQ), and then the images were analyzed using ImageJ to calculate image quality parameters such as noise, uniformity, and contrast to noise ratio (CNR). A protocol proposed by SEDENTEXCT, dose index 1 (DI1), was applied to dose measurements obtained using a thimble ionization chamber and cylindrical PMMA dose index phantom (SEDENTEXCT DI). Dose distributions were obtained using Gafchromic film. The phantoms were positioned in the FOV to imitate a clinical positioning. Results: The image noise was 6–12.5% which, when normalized to the difference of mean voxel value of PMMA and air, was comparable between different FOVs. Uniformity was 93.5ß 99.7% across the images. CNR was 1.7–4.2 and 6.3–14.3 for LDPE and Aluminum, respectively. Dose distributions were symmetric about the rotation angle's bisector. For large and medium FOVs at 4 mA and 80–90 kVp, DI1 values were in the range of 1.26–3.23 mGy. DI1 values were between 1.01–1.93 mGy for small FOV (5×5 cm{sup 2}) at 4–5 mA and 75–84 kVp. Conclusion: Noise decreased by increasing kVp, and the CNR increased for each FOV. When FOV size increased, image noise increased and CNR decreased. DI1 values were increased by increasing tube current (mA), tube voltage (kVp), and/or FOV. Funding for this project from NSERC Discovery grant, UBC Faculty of Dentistry Research Equipment Grant and UBC Faculty of

  3. SU-E-I-59: Image Quality and Dose Measurement for Partial Cone-Beam CT

    International Nuclear Information System (INIS)

    Abouei, E; Ford, N

    2014-01-01

    Purpose: To characterize performance of cone beam CT (CBCT) used in dentistry investigating quantitatively the image quality and radiation dose during dental CBCT over different settings for partial rotation of the x-ray tube. Methods: Image quality and dose measurements were done on a variable field of view (FOV) dental CBCT (Carestream 9300). X-ray parameters for clinical settings were adjustable for 2–10 mA, 60–90 kVp, and two optional voxel size values, but time was fixed for each FOV. Image quality was assessed by scanning cylindrical poly-methyl methacrylate (PMMA) image quality phantom (SEDENTEXCT IQ), and then the images were analyzed using ImageJ to calculate image quality parameters such as noise, uniformity, and contrast to noise ratio (CNR). A protocol proposed by SEDENTEXCT, dose index 1 (DI1), was applied to dose measurements obtained using a thimble ionization chamber and cylindrical PMMA dose index phantom (SEDENTEXCT DI). Dose distributions were obtained using Gafchromic film. The phantoms were positioned in the FOV to imitate a clinical positioning. Results: The image noise was 6–12.5% which, when normalized to the difference of mean voxel value of PMMA and air, was comparable between different FOVs. Uniformity was 93.5ß 99.7% across the images. CNR was 1.7–4.2 and 6.3–14.3 for LDPE and Aluminum, respectively. Dose distributions were symmetric about the rotation angle's bisector. For large and medium FOVs at 4 mA and 80–90 kVp, DI1 values were in the range of 1.26–3.23 mGy. DI1 values were between 1.01–1.93 mGy for small FOV (5×5 cm 2 ) at 4–5 mA and 75–84 kVp. Conclusion: Noise decreased by increasing kVp, and the CNR increased for each FOV. When FOV size increased, image noise increased and CNR decreased. DI1 values were increased by increasing tube current (mA), tube voltage (kVp), and/or FOV. Funding for this project from NSERC Discovery grant, UBC Faculty of Dentistry Research Equipment Grant and UBC Faculty of Dentistry

  4. [Measurements of tibio-femoral contact area after experimental partial and subtotal meniscectomie (author's transl)].

    Science.gov (United States)

    Hehne, H J; Riede, U N; Hauschild, G; Schlageter, M

    1981-02-01

    By means of section material, 24 partial and 58 subtotal meniscectomies were performed and the loss of tibio-femoral contact was evaluated by the Touchier-method planimetrically. In cases of partial resection this loss was 12% only, where as in subtotal resection 46%, where by the remaining contact zones lay in the central-, anyway meniscusfree area. The diagram of the chondral splitting lines showed a maximum of compression here, consecutively the remaining contact zone is reduced to the in earlier times most affected cartilage areas. The result correlates to the appearance of chondromalacies of the central tibial plateau in our own section cases and of postoperative osteoarthritis after subtotal meniscectomies in literature. Subtotal meniscectomies lead to incongruence and increased pressure. a pseudo-regeneration seems not to compensate the meniscus function sufficiently. A result for the clinic one should, when possible, resect menisci only partially.

  5. Motion-oriented 3D analysis of body measurements

    Science.gov (United States)

    Loercher, C.; Morlock, S.; Schenk, A.

    2017-10-01

    The aim of this project is to develop an ergonomically based and motion-oriented size system. New concepts are required in order to be able to deal competently with complex requirements of function-oriented workwear and personal protective equipment (PPE). Body dimensions change through movement, which are basis for motion optimized clothing development. This affects fit and ergonomic comfort. The situation has to be fundamentally researched in order to derive well-founded anthropometric body data, taking into account kinematic requirements of humans and to define functional dimensions for clothing industry. Research focus shall be on ergonomic design of workwear and PPE. There are huge differences in body forms, proportions and muscle manifestations between genders. An improved basic knowledge can be provided as a result, supporting development as well as sales of motion-oriented clothing with perfect fit for garment manufacturers.

  6. Partial Discharge Measurements in HV Rotating Machines in Dependence on Pressure of Coolant

    Directory of Open Access Journals (Sweden)

    I. Kršňák

    2002-01-01

    Full Text Available The influence of the pressure of the coolant used in high voltage rotating machines on partial discharges occurring in stator insulation is discussed in this paper. The first part deals with a theoretical analysis of the topic. The second part deals with the results obtained on a real generator in industrial conditions. Finally, theoretical assumptions and obtained results are compared.

  7. Quantitative genetics parameters show partial independent evolutionary potential for body mass and metabolism in stonechats from different populations

    NARCIS (Netherlands)

    Tieleman, B. I.; Versteegh, M. A.; Helm, B.; Dingemanse, N. J.; Volff, Jean-Nicolas

    2009-01-01

    Phenotypic variation in physiological traits, such as energy metabolism, is commonly subjected to adaptive interpretations, but little is known about the heritable basis or genetic correlations among physiological traits in non-domesticated species. Basal metabolic rate (BMR) and body mass are

  8. Reliability and validity for measurement of body composition: A field ...

    African Journals Online (AJOL)

    All three of these instruments do not involve high costs, do not require high technical skills, mobile, save time, and are suitable for use in large populations. Because all three instruments can estimate the percentage of body fat, but it is important to identify the most appropriate instruments and have high reliability. Hence, this ...

  9. Does Impedance Measure a Functional State of the Body Fat?

    Czech Academy of Sciences Publication Activity Database

    Větrovská, R.; Vilikus, Z.; Klaschka, Jan; Stránská, Z.; Svačina, Š.; Svobodová, Š.; Matoulek, M.

    2014-01-01

    Roč. 63, Suppl. 2 (2014), S309-S320 ISSN 0862-8408 Institutional support: RVO:67985807 Keywords : body composition * DEXA * fat mass * obesity * anthropometric methods * fat tissue functional properties Subject RIV: FB - Endocrinology, Diabetology, Metabolism, Nutrition Impact factor: 1.293, year: 2014

  10. Changes in body composition and other anthropometric measures ...

    African Journals Online (AJOL)

    Background and objectives. An understanding of the effect of highly active antiretroviral therapy (HAART) on various aspects of health, including nutritional status, is needed to ensure that population-specific guidelines can be developed for South Africa. This study aimed to investigate the changes in body composition and ...

  11. Corrections of the whole body counting for various measurement geometries

    International Nuclear Information System (INIS)

    Fueloep, M.; Ragan, P.; Lahham, A.

    1996-01-01

    A simple method was suggested for making corrections during the calibration of HPGe detectors employed for the whole-body counting of humans ranging from infants to adults. The results obtained by calculations were verified by using phantoms. (P.A.). 1 tab., 5 figs., 3 refs

  12. Body condition score, morphometric measurements and estimation of body weight in mature Icelandic horses in Denmark

    DEFF Research Database (Denmark)

    Jensen, Rasmus Bovbjerg; Danielsen, Signe H.; Tauson, Anne-Helene

    2016-01-01

    Background: Obesity is related to the development of several diseases like insulin resistance and laminitis in horses. The prevalence of obesity among mature Icelandic horses in Denmark has not been investigated previously. This study aimed to find the prevalence of obesity, to compare body condi...

  13. Development of a low tritium partial pressure permeation system for mass transport measurement in lead lithium eutectic

    International Nuclear Information System (INIS)

    Pawelko, R.; Shimada, M.; Katayama, K.; Fukada, S.; Terai, T.

    2014-01-01

    A new experimental system designed to investigate tritium mass transfer properties in materials important to fusion technology is operational at the Safety and Tritium Applied Research (STAR) facility located at the Idaho National Laboratory (INL). The tritium permeation measurement system was developed as part of the Japan/US TITAN collaboration to investigate tritium mass transfer properties in liquid lead lithium eutectic (LLE) alloy. The system is similar to a hydrogen/deuterium permeation measurement system developed at Kyushu University and also incorporates lessons learned from previous tritium permeation experiments conducted at the STAR facility. This paper describes the experimental system that is configured specifically to measure tritium mass transfer properties at low tritium partial pressures. We present preliminary tritium permeation results for α-Fe and α-Fe/LLE samples at 600degC and at tritium partial pressures between 1.0E-3 and 2.4 Pain helium. The preliminary results are compared with literature data. (author)

  14. Method for sensing and measuring a concentration or partial pressure of a reactant used in a redox reaction

    Science.gov (United States)

    Findl, E.

    1984-12-21

    A method for sensing or measuring the partial pressure or concentration of an electroactive species used in conjunction with an electrolyte, the method being characterized by providing a constant current between an anode and a cathode of an electrolyte-containing cell, while measuring changes in voltage that occur between either the anode and cathode or between a reference electrode and one of the main electrodes of the cell, thereby to determine the concentration or partial pressure of the electro-active species as a function of said measured voltage changes. The method of the invention can be practiced using either a cell having only an anode and a cathode, or using a cell having an anode and a cathode in combination with a reference electrode. Accurate measurements of small concentrations or partial pressures of electro-active species are obtainable with the method of the invention, by using constant currents of only a few microamperes between the anode and cathode of the cell, while the concentration-determining voltage is measured.

  15. Measuring Accurate Body Parameters of Dressed Humans with Large-Scale Motion Using a Kinect Sensor

    Directory of Open Access Journals (Sweden)

    Sidan Du

    2013-08-01

    Full Text Available Non-contact human body measurement plays an important role in surveillance, physical healthcare, on-line business and virtual fitting. Current methods for measuring the human body without physical contact usually cannot handle humans wearing clothes, which limits their applicability in public environments. In this paper, we propose an effective solution that can measure accurate parameters of the human body with large-scale motion from a Kinect sensor, assuming that the people are wearing clothes. Because motion can drive clothes attached to the human body loosely or tightly, we adopt a space-time analysis to mine the information across the posture variations. Using this information, we recover the human body, regardless of the effect of clothes, and measure the human body parameters accurately. Experimental results show that our system can perform more accurate parameter estimation on the human body than state-of-the-art methods.

  16. Indicadores para estimativa da digestibilidade parcial em bovinos Markers for measurements of partial digestion in cattle

    Directory of Open Access Journals (Sweden)

    Marcia Dias

    2007-06-01

    period (daytime vs. diurnal on nutrient digestion. Four crossbred Holstein x Zebu heifers fitted with ruminal and ileal cannulas were used in this trial. Animals were housed in individual pens and fed ad libitum bermudagrass hay plus 1 kg of concentrate (27% CP. The experiment lasted 60 days with seven days for diet adaptation and four days interval between each of the three 15-days experimental periods. Total fecal collection was done on day 1, 7, and 13, omasal sampling from day 2 to 4, and ileal digesta collection from day 8 to 10 of each period. Single [indigestible neutral detergent fiber (iNDF, indigestible acid detergent fiber (iADF, and chromium oxide (Cr2O3] and double system markers [Co-EDTA plus iNDF (Co-iNDF and Co-EDTA plus iADF (Co-iADF were used to measure flow of omasal digesta. Only single markers were used to determine ileal digesta flow. No significant difference was observed on partial nutrient digestibility comparing samples collected during the daytime with those collected during a 24-h period (diurnal suggesting that samples may be collect only during the daytime. Although iNDF, iADF and Co-iADF can all be used to estimate partial digestion of nutrients flowing past the omasum, it is recommended the use of internal markers (iNDF or iADF because of low costs and simple determination.

  17. Measurement of the γγ partial width of the χ2 charmonium resonance

    International Nuclear Information System (INIS)

    Armstrong, T.A.; Bettoni, D.; Bharadwaj, V.; Biino, C.; Borreani, G.; Broemmelsiek, D.; Buzzo, A.; Calabrese, R.; Ceccucci, A.; Cester, R.; Church, M.; Dalpiaz, P.; Dalpiaz, P.F.; Dibenedetto, R.; Dimitroyannis, D.; Fabbri, M.; Fast, J.; Gianoli, A.; Ginsburg, C.M.; Gollwitzer, K.; Hahn, A.; Hasan, M.A.; Hsueh, S.; Lewis, R.; Luppi, E.; Macri, M.; Majewska, A.M.; Mandelkern, M.; Marchetto, F.; Marinelli, M.; Marques, J.; Marsh, W.; Martini, M.; Masuzawa, M.; Menichetti, E.; Migliori, A.; Mussa, R.; Palestini, S.; Pallavicini, M.; Pastrone, N.; Patrignani, C.; Peoples, J. Jr.; Pesando, L.; Petrucci, F.; Pia, M.G.; Rapidis, P.A.; Ray, R.; Reid, J.; Rinaudo, G.; Roccuzzo, B.; Rosen, J.; Santroni, A.; Sarmiento, M.; Savrie, M.; Scalisi, A.; Schultz, J.; Seth, K.K.; Smith, A.; Smith, G.A.; Sozzi, M.; Trokenheim, S.; Weber, M.F.; Werkema, S.; Zhang, Y.; Zhao, J.; Zioulas, G.

    1993-01-01

    The E760 Collaboration has studied the reaction bar pp→χ 2 →γγ using a hydrogen gas jet target in the Fermilab antiproton acumulator ring. The following values are obtained for the branching ratio and partial width to two photons; B(χ 2 →γγ)=(1.60±0.45)x10 -4 and Γ(χ 2 →γγ)=321±95 eV

  18. Experimental Measurement of Frozen and Partially Melted Water Droplet Impact Dynamics

    Science.gov (United States)

    Palacios, Jose; Yan, Sihong; Tan, Jason; Kreeger, Richard E.

    2014-01-01

    High-speed video of single frozen water droplets impacting a surface was acquired. The droplets diameter ranged from 0.4 mm to 0.9 mm and impacted at velocities ranging from 140 m/sec to 309 m/sec. The techniques used to freeze the droplets and launch the particles against the surfaces is described in this paper. High-speed video was used to quantify the ice accretion area to the surface for varying impact angles (30 deg, 45 deg, 60 deg), impacting velocities, and break-up angles. An oxygen /acetylene cross-flow flame used to ensure partial melting of the traveling frozen droplets is also discussed. A linear relationship between impact angle and ice accretion is identified for fully frozen particles. The slope of the relationship is affected by impact speed. Perpendicular impacts, i.e. 30 deg, exhibited small differences in ice accretion for varying velocities, while an increase of 60% in velocity from 161 m/sec to 259 m/sec, provided an increase on ice accretion area of 96% at an impact angle of 60 deg. The increase accretion area highlights the importance of impact angle and velocity on the ice accretion process of ice crystals. It was experimentally observed that partial melting was not required for ice accretion at the tested velocities when high impact angles were used (45 and 60 deg). Partially melted droplets doubled the ice accretion areas on the impacting surface when 0.0023 Joules were applied to the particle. The partially melted state of the droplets and a method to quantify the percentage increase in ice accretion area is also described in the paper.

  19. Measurements of Charmless Three-Body and Quasi-Two-Body B Decays

    Energy Technology Data Exchange (ETDEWEB)

    Barrera, Barbara

    2000-08-28

    The authors present preliminary results of a search for several exclusive charmless hadronic B decays from electron-positron annihilation data collected by the BaBar detector near the Upsilon(4S) resonance. These include three-body decay modes with final states h{+-}h{sup minus-plus}h{+-} and h{+-}h{sup minus-plus}pi{sup 0}, and quasi-two-body decay modes with final states X{sup 0}h and X{sup 0}K{sub S}{sup 0}, where h = pi or K and X{sup 0} = eta-prime or omega. They find beta(B{sup 0} --> rho{sup minus-plus}pi{sup {+-}}) = (49{+-}13{sub {minus}5}{sup +6}) x 10{sup {minus}6} and beta(B{sup +} --> eta-prime-K{sup +}) = (62{+-}18{+-}8) x 10{sup {minus}6} and present upper limits for right other decays.

  20. Measurement of Local Partial Pressure of Oxygen in the Brain Tissue under Normoxia and Epilepsy with Phosphorescence Lifetime Microscopy

    Science.gov (United States)

    Zhang, Cong; Bélanger, Samuel; Pouliot, Philippe; Lesage, Frédéric

    2015-01-01

    In this work a method for measuring brain oxygen partial pressure with confocal phosphorescence lifetime microscopy system is reported. When used in conjunction with a dendritic phosphorescent probe, Oxyphor G4, this system enabled minimally invasive measurements of oxygen partial pressure (pO2) in cerebral tissue with high spatial and temporal resolution during 4-AP induced epileptic seizures. Investigating epileptic events, we characterized the spatio-temporal distribution of the "initial dip" in pO2 near the probe injection site and along nearby arterioles. Our results reveal a correlation between the percent change in the pO2 signal during the "initial dip" and the duration of seizure-like activity, which can help localize the epileptic focus and predict the length of seizure. PMID:26305777

  1. Measurement of Local Partial Pressure of Oxygen in the Brain Tissue under Normoxia and Epilepsy with Phosphorescence Lifetime Microscopy.

    Science.gov (United States)

    Zhang, Cong; Bélanger, Samuel; Pouliot, Philippe; Lesage, Frédéric

    2015-01-01

    In this work a method for measuring brain oxygen partial pressure with confocal phosphorescence lifetime microscopy system is reported. When used in conjunction with a dendritic phosphorescent probe, Oxyphor G4, this system enabled minimally invasive measurements of oxygen partial pressure (pO2) in cerebral tissue with high spatial and temporal resolution during 4-AP induced epileptic seizures. Investigating epileptic events, we characterized the spatio-temporal distribution of the "initial dip" in pO2 near the probe injection site and along nearby arterioles. Our results reveal a correlation between the percent change in the pO2 signal during the "initial dip" and the duration of seizure-like activity, which can help localize the epileptic focus and predict the length of seizure.

  2. 47 CFR 73.154 - AM directional antenna partial proof of performance measurements.

    Science.gov (United States)

    2010-10-01

    ... available to the FCC upon request. Maps showing new measurement points, i.e., points not measured in the...) Measurement points shall be selected from the points measured in latest full proof of performance provided..., the licensee shall measure directional field strength for comparison to either the directional or the...

  3. Measurement of partial coefficients of sputtering of titanium atoms from TiC and TiN coatings

    International Nuclear Information System (INIS)

    Vychegzhanin, G.A.; Gribanov, Yu.A.; Dikij, N.P.; Zhmurin, P.N.; Letuchij, A.N.; Matyash, P.P.; Sidokur, P.I.; Shono, D.A.

    1989-01-01

    Method of laser fluorescent spectroscopy was used to measure partial coefficients of sputtering of titanium atoms from TiC and TiN coatings under irradiation by 1 keV hydrogen ions. Irradiation was conducted in a plant with reflective discharge. Investigation of damaged layer in irradiated samples was conducted. The presence of near-the-surface layer enrichment with titanium atoms was revealed both in TiC and TiN samples. 12 refs.; 4 figs

  4. Quality of life outcome measures following partial glossectomy: Assessment using the UW-QOL scale

    Directory of Open Access Journals (Sweden)

    Kazi R

    2008-01-01

    Full Text Available Background: The consequences of a diagnosis of head and neck cancer and the impact of treatment have a clear and direct influence on well-being and associated quality of life (QOL in these patients. Aims: To determine the QOL in head and neck cancer patients following a partial glossectomy operation. Design and Setting: Cross-sectional cohort study; Head and Neck Oncology Unit, tertiary referral center. Materials and Methods: 38 patients with partial glossectomy were assessed with the University of Washington head and neck quality of life (UW-QOL scale, version 4. Statistical Analysis: Statistical analysis was performed using the Statistical Package for Social Sciences 10.0 (SPSS Inc, Chicago version III. Information from the scale was correlated using the Mann Whitney test. A P value less than/equal to 0.05 was considered as significant. Results: The mean (sd composite score of the QOL in our series was 73.6 (16.1. The majority (71.8% quoted their QOL as good or very good. Swallowing (n = 16, 47.1%, speech (n = 15, 44.1% and saliva (n = 15, 44.1% were most commonly cited issues over the last 7 days. On the other hand, the groups with reconstruction, neck dissection, complications and radiotherapy demonstrated a significant reduction of quality of life scores (Mann Whitney test, P < 0.05. Conclusion: The composite score and overall QOL as assessed using the UW-QOL scale (version 4 were modestly high in our series of partial glossectomy patients. Swallowing, speech, and saliva are regarded as the most important issues. Stage of the disease, neck dissection, reconstruction, complications, radiotherapy and time since operation were seen to significantly affect domain scores.

  5. Development of a wall-shear-stress sensor and measurements in mini-channels with partial blockages

    Science.gov (United States)

    Afara, Samer; Medvescek, James; Mydlarski, Laurent; Baliga, Bantwal R.; MacDonald, Mark

    2014-05-01

    The design, construction, operation and validation of a wall-shear-stress sensor, and measurements obtained using this sensor in air flows downstream of partial blockages in a mini-channel are presented. The sensor consisted of a hot wire mounted over a small rectangular slot and operated using a constant-temperature anemometer. It was used to investigate flows similar to those within the mini-channels inside notebook computers. The overall goal of the present work was to develop a sensor suitable for measurements of the wall-shear stress in such flows, which can be used to validate corresponding numerical simulations, as the latter are known to be often surprisingly inaccurate. To this end, measurements of the wall-shear stress, and the corresponding statistical moments and power spectral densities, were obtained at different distances downstream of the partial blockage, with blockage ratios of 39.7, 59.2, and 76.3 %. The Reynolds number (based on average velocity and hydraulic diameter) ranged from 100 to 900. The results confirmed the presence of unsteadiness, separation, reattachment, and laminar-turbulent transition in the ostensibly laminar flow of air in mini-channels with partial blockages. The present results demonstrate why accurate numerical predictions of cooling air flows in laptop and notebook computers remain a challenging task.

  6. Applications of quantum measurement in single and many body systems

    International Nuclear Information System (INIS)

    Steixner, V.

    2010-01-01

    This thesis contains a study about the influence of the back action of a signal emitted by a trapped ion onto itself. The continuous measurement signal is used to alter the motional state of the ion, corresponding to classical friction, in order to cool the ion. The quantum mechanical evolution of the ion with the help of stochastic Schroedinger- and master equations is explored, as well as experimental results. A second method of feedback to obtain the momentum necessary for cooling by means of electromagnetically induced transparency is discussed next. This method allows for a theoretical cooling down to the motional ground state. In a second part of the thesis, the measurement of particle currents in optical lattices is discussed. The usual method of measuring spatial correlations in a cold gas, the time-of-flight method, disadvantageously destroys the measured sample. Here a measurement scheme for atoms with an internal Lambda level structure, coupled with lasers as a Raman transition, is used instead. The measured photons are transformed with the help of homodyne detection into a continuous photon current proportional to the particle current. This thesis contains numerical and analytical calculations for this measurement process and the back action on the measured system. As an application example, the measurement of superfluid currents in a ring optical lattice is described, as well as the entanglement of two of these macroscopic quantum objects. (author) [de

  7. Technical Note: Partial body irradiation of mice using a customized PMMA apparatus and a clinical 3D planning/LINAC radiotherapy system

    Energy Technology Data Exchange (ETDEWEB)

    Karagounis, Ilias V.; Koukourakis, Michael I., E-mail: targ@her.forthnet.gr, E-mail: mkoukour@med.duth.gr [Department of Radiotherapy–Oncology, Radiopathology and Radiobiology Unit, Medical School, Democritus University of Thrace, Alexandroupolis 68100 (Greece); Abatzoglou, Ioannis M., E-mail: abadzoglou@yahoo.gr [Medical Physics Department, University General Hospital of Alexandroupolis, Alexandroupolis 68100 (Greece)

    2016-05-15

    Purpose: In vivo radiobiology experiments involving partial body irradiation (PBI) of mice are of major importance because they allow for the evaluation of individual organ tolerance; overcoming current limitations of experiments using lower dose, whole body irradiation. In the current study, the authors characterize and validate an effective and efficient apparatus for multiple animal PBI, directed to the head, thorax, or abdomen of mice. Methods: The apparatus is made of polymethylmethacrylate and consists of a rectangular parallelepiped prism (40 cm × 16 cm × 8 cm), in which five holes were drilled to accomodate standard 60 ml syringes, each housing an unanesthetized, fully immobilized mouse. Following CT-scanning and radiotherapy treatment planning, radiation fields were designed to irradiate the head, thorax, or abdomen of the animal. Thermoluminescent dosimeters (TLDs) were used to confirm the treatment planning dosimetry for primary beam and scattered radiation. Results: Mice are efficiently placed into 60 ml syringes and immobilized, without the use of anesthetics. Although partial rotational movement around the longitudinal axis and a minor 2 mm forward/backward movement are permitted, this does not compromise the irradiation of the chosen body area. TLDs confirmed the dose values predicted by the treatment planning dosimetry, both for primary beam and scattered radiation. Conclusions: The customized PMMA apparatus described and validated is cost-effective, convenient to use, and efficient in performing PBI without the use of anesthesia. The developed apparatus permits the isolated irradiation of the mouse head, thorax, and abdomen. Importantly, the apparatus allows the delivery of PBI to five mice, simultaneously, representing an efficient way to effectively expose a large number of animals to PBI through multiple daily fractions, simulating clinical radiotherapy treatment schedules.

  8. Classification of Partial Discharge Measured under Different Levels of Noise Contamination.

    Directory of Open Access Journals (Sweden)

    Wong Jee Keen Raymond

    Full Text Available Cable joint insulation breakdown may cause a huge loss to power companies. Therefore, it is vital to diagnose the insulation quality to detect early signs of insulation failure. It is well known that there is a correlation between Partial discharge (PD and the insulation quality. Although many works have been done on PD pattern recognition, it is usually performed in a noise free environment. Also, works on PD pattern recognition in actual cable joint are less likely to be found in literature. Therefore, in this work, classifications of actual cable joint defect types from partial discharge data contaminated by noise were performed. Five cross-linked polyethylene (XLPE cable joints with artificially created defects were prepared based on the defects commonly encountered on site. Three different types of input feature were extracted from the PD pattern under artificially created noisy environment. These include statistical features, fractal features and principal component analysis (PCA features. These input features were used to train the classifiers to classify each PD defect types. Classifications were performed using three different artificial intelligence classifiers, which include Artificial Neural Networks (ANN, Adaptive Neuro-Fuzzy Inference System (ANFIS and Support Vector Machine (SVM. It was found that the classification accuracy decreases with higher noise level but PCA features used in SVM and ANN showed the strongest tolerance against noise contamination.

  9. Simultaneous and multi-point measurement of ammonia emanating from human skin surface for the estimation of whole body dermal emission rate.

    Science.gov (United States)

    Furukawa, Shota; Sekine, Yoshika; Kimura, Keita; Umezawa, Kazuo; Asai, Satomi; Miyachi, Hayato

    2017-05-15

    Ammonia is one of the members of odor gases and a possible source of odor in indoor environment. However, little has been known on the actual emission rate of ammonia from the human skin surface. Then, this study aimed to estimate the whole-body dermal emission rate of ammonia by simultaneous and multi-point measurement of emission fluxes of ammonia employing a passive flux sampler - ion chromatography system. Firstly, the emission fluxes of ammonia were non-invasively measured for ten volunteers at 13 sampling positions set in 13 anatomical regions classified by Kurazumi et al. The measured emission fluxes were then converted to partial emission rates using the surface body areas estimated by weights and heights of volunteers and partial rates of 13 body regions. Subsequent summation of the partial emission rates provided the whole body dermal emission rate of ammonia. The results ranged from 2.9 to 12mgh -1 with an average of 5.9±3.2mgh -1 per person for the ten healthy young volunteers. The values were much greater than those from human breath, and thus the dermal emission of ammonia was found more significant odor source than the breath exhalation in indoor environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Measurement of Turbid Body Optical Properties Using Attenuation of ...

    African Journals Online (AJOL)

    The main objective of this work was to investigate the laser light interaction with highly diffusing tissue media like milk. In this work collimated transmission, fluence rate measurements and angular distribution of intensity measurements were made on three types of milks having different fat contents such as fresh cow milk ...

  11. Whole body [O-15]water pharmacokinetics measured in blood

    NARCIS (Netherlands)

    Maguire, RP; Spyrou, NM; Leenders, KL

    A simple pharmacokinetic model to explain the time course of [0-15]water in human whole blood after bolus injection is described. The model has been derived from measurements in twelve healthy volunteers who were measured repeatedly, resulting in 67 datasets, made in the context of PET blood flow

  12. Measurements of the total-body potassium contents. Application of reference value with the whole-body counter

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tetsuo [Chiba Univ. (Japan). Inst. for Training Radiological Technicians; Saegusa, Kenji; Arimizu, Noboru; Kuniyasu, Yoshio; Itoh, Hisao

    2001-08-01

    The total-body potassium contents were measured in 405 healthy volunteers and 186 patients with whole body counter in Chiba University Hospital. The total-body potassium contents was expressed by the reference value (R value). The R value was calculated as measured potassium contents (g) divided by the body surface area (m{sup 2}) and adjusted by age and sex of healthy persons. The R value was 100.65{+-}9.22% in 405 healthy volunteers. Those of each disease were as follows: liver cirrhosis; 94.24{+-}11.22%, chronic hepatitis; 95.74{+-}11.24%, hyperthyroidism; 99.37{+-}10.8%, periodic paralysis; 82.0{+-}9.01%, Barter's syndrome; 93.99{+-}9.86%, myasthenia gravis; 97.34{+-}6.42% and hypo-potassemia; 90.64{+-}11.76%, respectively. The R values of other diseases such as uterine cancer, breast cancer, anemia, hypertension were 97.78{+-}11.5%, 99.22{+-}8.88%, 96.64{+-}12.73%, 98.5{+-}9.63% respectively. Fourteen patients showed especially lower R values under 75%. These were 1 liver cirrhosis, 3 hypertension, 1 diabetes mellitus, 3 hypo-potassemia, 1 periodic paralysis, 2 Barter's syndrome, 2 chemical poisoning, and 1 breast cancer. Follow-up study was performed in some patients with the lower R values. The result of follow-up study showed that there was a relationship between improvement of symptoms and increase of total body potassium contents. (author)

  13. Body Image in Transmen: Multidimensional Measurement and the Effects of Mastectomy.

    Science.gov (United States)

    van de Grift, Tim C; Kreukels, Baudewijntje P C; Elfering, Lian; Özer, Müjde; Bouman, Mark-Bram; Buncamper, Marlon E; Smit, Jan Maerten; Mullender, Margriet G

    2016-11-01

    Transmen are generally dissatisfied with their breasts and often opt for mastectomy. However, little is known about the specific effects of this procedure on this group's body image. To prospectively assess the effect of mastectomy on the body image of transmen, including cognitive, emotional, and behavioral aspects. During a 10-month period, all transmen applying for mastectomy were invited to participate in this study. The 33 participants completed assessments preoperatively and at least 6 months postoperatively. Participants were surveyed on body satisfaction (Body Image Scale for Transsexuals), body attitudes (Multidimensional Body-Self Relations Questionnaire), appearance schemas (Appearance Schemas Inventory), situational bodily feelings (Situational Inventory of Body Image Dysphoria), body image-related quality of life (Body Image Quality of Life Inventory), and self-esteem (Rosenberg Self-Esteem Scale). Control values were retrieved from the literature and a college sample. Before surgery, transmen reported less positive body attitudes and satisfaction, a lower self-esteem and body image-related quality of life compared with cisgender men and women. Mastectomy improved body satisfaction most strongly, although respondents reported improvements in all domains (eg, decreased dysphoria when looking in the mirror and improved feelings of self-worth). Most outcome measurements were strongly correlated. Mastectomy improves body image beyond satisfaction with chest appearance alone. Body satisfaction and feelings of "passing" in social situations are associated with a higher quality of life and self-esteem. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Triceps skin fold thickness as a measure of body fat in Nigerian

    African Journals Online (AJOL)

    owner

    2012-11-26

    Nov 26, 2012 ... and body fat distribution.2,3 Skin fold thickness measure- ments are a well ... different recognized areas for the measurement of SFT, ..... 'western children.' These .... Asia Pacific J Clin ... sity in children and young people:.

  15. Food insecurity partially mediates associations between social disadvantage and body composition among older adults in india: Results from the study on global AGEing and adult health (SAGE).

    Science.gov (United States)

    Schrock, Joshua M; McClure, Heather H; Snodgrass, J Josh; Liebert, Melissa A; Charlton, Karen E; Arokiasamy, Perianayagam; Naidoo, Nirmala; Kowal, Paul

    2017-11-01

    Our objective was to test whether food insecurity mediates cross-sectional associations between social disadvantage and body composition among older adults (aged 50+) in India (n = 6556). Adjusting for key sociodemographic and dietary variables, we examined whether markers of social disadvantage (lower educational attainment, lower household wealth, belonging to a disadvantaged caste/tribe, and belonging to a minority religion) were associated with food insecurity. We then examined whether food insecurity, in turn, was associated with anthropometric measures of body composition, body mass index (BMI), and waist circumference (WC). We also tested whether food insecurity mediated the relationship between social disadvantage and body composition. In adjusted models, lower household wealth [lowest quintile (Q5) vs highest quintile (Q1): odds ratio (OR) = 13.57, P insecurity. Those who were severely food insecure had greater odds of being underweight (OR = 1.36, P insecurity explained 4.7%-29.7% of the relationship between social disadvantage and body composition, depending on the variables considered. Our results are consistent with the hypothesis that food insecurity is a mechanism linking social disadvantage and body composition among older adults in India. These analyses contribute to a better understanding of processes leading to variation in body composition, which may help enhance the design of interventions aimed at improving population nutritional status. © 2017 Wiley Periodicals, Inc.

  16. Partial alignment and measurement of residual dipolar couplings of proteins under high hydrostatic pressure

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Yinan; Wand, A. Joshua, E-mail: wand@mail.med.upenn.edu [University of Pennsylvania, Department of Biochemistry and Biophysics, Johnson Research Foundation (United States)

    2013-08-15

    High-pressure NMR spectroscopy has emerged as a complementary approach for investigating various structural and thermodynamic properties of macromolecules. Noticeably absent from the array of experimental restraints that have been employed to characterize protein structures at high hydrostatic pressure is the residual dipolar coupling, which requires the partial alignment of the macromolecule of interest. Here we examine five alignment media that are commonly used at ambient pressure for this purpose. We find that the spontaneous alignment of Pf1 phage, d(GpG) and a C12E5/n-hexnanol mixture in a magnetic field is preserved under high hydrostatic pressure. However, DMPC/DHPC bicelles and collagen gel are found to be unsuitable. Evidence is presented to demonstrate that pressure-induced structural changes can be identified using the residual dipolar coupling.

  17. In vivo measurement of total body carbon using 238Pu/Be neutron sources

    International Nuclear Information System (INIS)

    Sutcliffe, J.F.; Mitra, S.; Hill, G.L.

    1990-01-01

    Total body carbon has been measured by in vivo neutron activation analysis (IVNAA) in 278 surgical gastroenterological patients and 29 normal volunteers. This is based on the inelastic scattering reaction { 12 C(n,n') 12 C*} for neutrons with energy above 4.8MeV, producing 4.43 MeV gamma rays. Since only part of the body is scanned, total body carbon is estimated as the ratio of the gamma ray emission from carbon to the emission from hydrogen, using hydrogen as the internal standard. The precision of the estimate is ±1.6kg for a whole body dose of 0.3mSv. There is a significant difference between the estimates of total body water from IVNAA measurements of carbon and nitrogen and measurements of body water in these subjects by tritium dilution (t=3.1, p < 0.005). (author)

  18. Relationship of body mass index and waist to hip ratio measurement with hypertension in young adult medical students

    International Nuclear Information System (INIS)

    Zafar, S.; Haque, I.U.; Rehman, A.U.

    2007-01-01

    To examine the BMI profile and waist to hip ratio measurements of young adult medical students of Lahore medical and dental college and its relationship with hypertension. All the students of Lahore medical and dental college were asked to undergo physical examination. Height, weight, waist circumference, hip circumference, systolic and diastolic blood pressure were recorded. The partial correlation coefficient was used to quantify the association between BMI and waist-to-hip circumference ratio with systolic and diastolic blood pressure. Linear regression analysis was used to assess the influence of body mass index and waist-to-hip circumference ratio on the variance of systolic and diastolic BP. Mean BMI was 23.24 (SD+-4.31). Descriptive analysis revealed that 103 (21.3%) of the study population were classified as underweight, 251 (52 %) as normal weight, 99 (20.5%) as overweight, and 30 (6.2 %) as obese. Abdominal adiposity, as measured by increased WHR, was present in 56 subjects (11.59 %). Partial correlation controlled for age revealed strong positive correlation between BMI and WHR for males. 7.24% had high systolic blood pressure, minimum systolic BP was 90 while maximum being 160 mmHg. Same was the value for high diastolic blood pressure i.e. 35 (7.24%), range was from 60 to 100mm Hg. Results of the partial correlation coefficient controlled for age, indicated a significant positive correlation between SBP and DBP. Stepwise linear regression analysis controlled for age revealed that both body mass index and waist-to-hip circumference ratio were independently correlated with both systolic and diastolic blood pressures. The present results suggest that prevalence of overweight and obesity among the medical students is higher than in general population. Those with either higher BMI or central adiposity distribution are potential candidates of increased risk of hypertension and cardiovascular disease. (author)

  19. Measured versus self-reported body height and body mass in patients after an acute coronary syndrome

    Directory of Open Access Journals (Sweden)

    Domagała Zygmunt

    2017-12-01

    Full Text Available The basic anthropometric data describing a person in the broadest context are body weight and height, two of the most frequently analyzed somatometric parameters. The same is true I in relation to clinical patients. The aim of the present study was to compare the self-reported and actual body weight, height and BMI in patients suffering from coronary artery disease and undergoing cardiac rehabilitation. The study sample consisted of 100 patients treated for coronary artery disease. The patients were asked to state their body weight and height. At the same time a three-person study team took measurements, which were later the basis for verification and objective assessment of the data provided by the patients. Statistical analysis was performed with Statistics 11.0 PL software. The analysis of mean results for the assessed group of patients has shown the presence of statistically significant differences between declared and actual data. The differences were observed for both male and female study population. It has been proven that the subjects declare greater body height (mean value 1.697 m vs. 1.666 m and lower body weight (80.643 kg vs. 82.051 kg. Based on the data from surveys and direct measurements, the body mass index for the self-reported and actual data was calculated. A comparison of these values has shown considerable statistically significant differences. The differences between declared and actual data point to highly subjective self-assessment, which disqualifies the declared data in the context of monitoring of treatment and rehabilitation processes. The authors believe that actual data should be used in direct trial examination of patients suffering from coronary artery disease who presented with acute coronary syndrome.

  20. Effects of conventional overground gait training and a gait trainer with partial body weight support on spatiotemporal gait parameters of patients after stroke.

    Science.gov (United States)

    Park, Byoung-Sun; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Noh, Ji-Woong; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Kim, Junghwan

    2015-05-01

    [Purpose] The purpose of this study was to confirm the effects of both conventional overground gait training (CGT) and a gait trainer with partial body weight support (GTBWS) on spatiotemporal gait parameters of patients with hemiparesis following chronic stroke. [Subjects and Methods] Thirty stroke patients were alternately assigned to one of two treatment groups, and both groups underwent CGT and GTBWS. [Results] The functional ambulation classification on the affected side improved significantly in the CGT and GTBWS groups. Walking speed also improved significantly in both groups. [Conclusion] These results suggest that the GTBWS in company with CGT may be, in part, an effective method of gait training for restoring gait ability in patients after a stroke.

  1. Measurement of total-body oxygen, nitrogen, and carbon in vivo by photon activation analysis

    International Nuclear Information System (INIS)

    Ulin, K.

    1984-01-01

    With the aim of assessing nutritional status, the feasibility of measuring the total body quantities of the major body elements, i.e. oxygen, nitrogen, and carbon, using the photon beam of a 45 MV betatron and a whole-body counter, has been evaluated in detail. Following photon activation a single energy γ-radiation (.511 MeV) is observed from all three elements to be measured. The half-lives of 15 O, 13 N, and 11 C, however, are sufficiently different (20.5 min, 10.0 min, and 20.4 min. respectively) to permit their measurement from an analysis of the measured decay curve. Following corrections for interfering reactions, a computer curve-fitting algorithm is used to resolve the data into 15 O, 13 N, and 11 C components. Measurements of O, N, and C have been made both in phantoms and in live and dead rats. A comparison of the body composition results from this technique with results from chemical analysis indicates that measured carbon can quite accurately predict total body fat. The comparison of the total body nitrogen measurement by photon activation with total body protein by chemical analysis was inconclusive and suggests that further work be done to verify the estimated accuracy of the nitrogen measurement

  2. Comparison of capacitive and inductive sensors designed for partial discharges measurements in electrical power apparatus

    Directory of Open Access Journals (Sweden)

    Kunicki Michał

    2017-01-01

    Full Text Available In the paper results of simultaneously conducted measurements achieved using capacitive and inductive sensors are presented according to different PD model sources immersed in a mineral transformer insulation oil. All measurements are preceded under laboratory conditions using typical measurement set up commonly applied for on-site PD detection: measuring impedance and capacitor and high frequency current transformer (HFCT are used respectively. Measuring frequency and voltage level influence as well as phase resolved PD patterns analysis are investigated in the research. Various fundamental PD signal descriptors assigned for selected frequencies are also proposed and compared for chosen sensors. The main purpose of the presented research is to compare PD measurement results achieved using selected type of sensors during laboratory measurements and to point the best application areas in fields of PD detection in high voltage apparatus under normal operating conditions. Furthermore a proper measurement results interpretation coming from different sensors as well as measurement conducting problems and achieved patterns disparities are also discussed in the paper.

  3. Optimized statistical parametric mapping for partial-volume-corrected amyloid positron emission tomography in patients with Alzheimer's disease and Lewy body dementia

    Science.gov (United States)

    Oh, Jungsu S.; Kim, Jae Seung; Chae, Sun Young; Oh, Minyoung; Oh, Seung Jun; Cha, Seung Nam; Chang, Ho-Jong; Lee, Chong Sik; Lee, Jae Hong

    2017-03-01

    We present an optimized voxelwise statistical parametric mapping (SPM) of partial-volume (PV)-corrected positron emission tomography (PET) of 11C Pittsburgh Compound B (PiB), incorporating the anatomical precision of magnetic resonance image (MRI) and amyloid β (A β) burden-specificity of PiB PET. First, we applied region-based partial-volume correction (PVC), termed the geometric transfer matrix (GTM) method, to PiB PET, creating MRI-based lobar parcels filled with mean PiB uptakes. Then, we conducted a voxelwise PVC by multiplying the original PET by the ratio of a GTM-based PV-corrected PET to a 6-mm-smoothed PV-corrected PET. Finally, we conducted spatial normalizations of the PV-corrected PETs onto the study-specific template. As such, we increased the accuracy of the SPM normalization and the tissue specificity of SPM results. Moreover, lobar smoothing (instead of whole-brain smoothing) was applied to increase the signal-to-noise ratio in the image without degrading the tissue specificity. Thereby, we could optimize a voxelwise group comparison between subjects with high and normal A β burdens (from 10 patients with Alzheimer's disease, 30 patients with Lewy body dementia, and 9 normal controls). Our SPM framework outperformed than the conventional one in terms of the accuracy of the spatial normalization (85% of maximum likelihood tissue classification volume) and the tissue specificity (larger gray matter, and smaller cerebrospinal fluid volume fraction from the SPM results). Our SPM framework optimized the SPM of a PV-corrected A β PET in terms of anatomical precision, normalization accuracy, and tissue specificity, resulting in better detection and localization of A β burdens in patients with Alzheimer's disease and Lewy body dementia.

  4. Energy measurement and fragment identification using digital signals from partially depleted Si detectors

    International Nuclear Information System (INIS)

    Pasquali, G.; Pastore, G.; Barlini, S.; Bini, M.; Poggi, G.; Stefanini, A.A.; Valdre, S.; Le Neindre, N.; Bougault, R.; Lopez, O.; Vient, E.; Ademard, G.; Borderie, B.; Edelbruck, P.; Rivet, M.F.; Salomon, F.; Bonnet, E.; Chbihi, A.; Frankland, J.D.; Gruyer, D.; Casini, G.; Olmi, A.; Piantelli, S.; Cinausero, M.; Gramegna, F.; Marchi, T.; Duenas, J.A.; Kordyasz, A.; Kozik, T.; Twarog, T.; Morelli, L.; Ordine, A.; Parlog, M.; Rosato, E.; Spadaccini, G.; Alba, R.; Maiolino, C.; Santonocito, D.

    2014-01-01

    A study of identification properties of a Si-Si ΔE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated with a depleted layer ranging from 90% to 60% of the detector thickness. Fragment identification has been performed using either the ΔE-E technique or the Pulse Shape Analysis (PSA). Both detectors are reverse mounted: particles enter from the low field side, to enhance the PSA performance. The achieved charge and mass resolution has been quantitatively expressed using a Figure of Merit (FoM). Charge collection efficiency has been evaluated and the possibility of energy calibration corrections has been considered. We find that the ΔE-E performance is not affected by incomplete depletion even when only 60% of the wafer is depleted. Isotopic separation capability improves at lower bias voltages with respect to full depletion, though charge identification thresholds are higher than at full depletion. Good isotopic identification via PSA has been obtained from a partially depleted detector, whose doping uniformity is not good enough for isotopic identification at full depletion. (orig.)

  5. Objective measures of renal mass anatomic complexity predict rates of major complications following partial nephrectomy.

    Science.gov (United States)

    Simhan, Jay; Smaldone, Marc C; Tsai, Kevin J; Canter, Daniel J; Li, Tianyu; Kutikov, Alexander; Viterbo, Rosalia; Chen, David Y T; Greenberg, Richard E; Uzzo, Robert G

    2011-10-01

    The association between tumor complexity and postoperative complications after partial nephrectomy (PN) has not been well characterized. We evaluated whether increasing renal tumor complexity, quantitated by nephrometry score (NS), is associated with increased complication rates following PN using the Clavien-Dindo classification system (CCS). We queried our prospectively maintained kidney cancer database for patients undergoing PN from 2007 to 2010 for whom NS was available. All patients underwent PN. Tumors were categorized into low- (NS: 4-6), moderate- (NS: 7-9), and high-complexity (NS: 10-12) lesions. Complication rates within 30 d were graded (CCS: I-5), stratified as minor (CCS: I or 2) or major (CCS: 3-5), and compared between groups. A total of 390 patients (mean age: 58.0 ± 11.9 yr; 66.9% male) undergoing PN (44.6% open, 55.4% robotic) for low- (28%), moderate- (55.6%), and high-complexity (16.4%) tumors (mean tumor size: 3.74 ± 2.4 cm; median: 3.2 cm) from 2007 to 2010 were identified. Tumor size, estimated blood loss, and ischemia time all significantly differed (prenal tumors. Copyright © 2011 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  6. Novel Measures to Assess the Effects of Partial Sleep Deprivation on Sensory, Working, and Permanent Memory

    Directory of Open Access Journals (Sweden)

    Dominique Gosselin

    2017-09-01

    Full Text Available Sleepiness has repeatedly been demonstrated to affect performance on a variety of cognitive tasks. While the effects of total sleep deprivation (TSD have been extensively studied, acute partial sleep deprivation (PSD, a more frequent form of sleep loss, has been studied much less often. The present study examined the effects of sleep deprivation on novel tasks involving classic sensory, working, and permanent memory systems. While the tasks did implicate different memory systems, they shared a need for effortful, sustained attention to maintain successful performance. Because of the novelty of the tasks, an initial study of the effects of TSD was carried out. The effects of PSD were subsequently examined in a second study, in which subjects were permitted only 4 h of sleep. A general detrimental effect of both total and PSD on accuracy of detection was observed and to a lesser extent, a slowing of the speed of responding on the different tasks. This overall effect is best explained by the often-reported inability to sustain attention following sleep loss. Specific effects on distinct cognitive processes were also observed, and these were more apparent following total than PSD.

  7. Novel Measures to Assess the Effects of Partial Sleep Deprivation on Sensory, Working, and Permanent Memory.

    Science.gov (United States)

    Gosselin, Dominique; De Koninck, Joseph; Campbell, Kenneth

    2017-01-01

    Sleepiness has repeatedly been demonstrated to affect performance on a variety of cognitive tasks. While the effects of total sleep deprivation (TSD) have been extensively studied, acute partial sleep deprivation (PSD), a more frequent form of sleep loss, has been studied much less often. The present study examined the effects of sleep deprivation on novel tasks involving classic sensory, working, and permanent memory systems. While the tasks did implicate different memory systems, they shared a need for effortful, sustained attention to maintain successful performance. Because of the novelty of the tasks, an initial study of the effects of TSD was carried out. The effects of PSD were subsequently examined in a second study, in which subjects were permitted only 4 h of sleep. A general detrimental effect of both total and PSD on accuracy of detection was observed and to a lesser extent, a slowing of the speed of responding on the different tasks. This overall effect is best explained by the often-reported inability to sustain attention following sleep loss. Specific effects on distinct cognitive processes were also observed, and these were more apparent following total than PSD.

  8. Energy measurement and fragment identification using digital signals from partially depleted Si detectors

    Energy Technology Data Exchange (ETDEWEB)

    Pasquali, G.; Pastore, G.; Barlini, S.; Bini, M.; Poggi, G.; Stefanini, A.A.; Valdre, S. [Universita di Firenze, Dipartimento di Fisica, Sesto Fiorentino (Italy); INFN, Sezione di Firenze, Sesto Fiorentino (Italy); Le Neindre, N.; Bougault, R.; Lopez, O.; Vient, E. [ENSICAEN et Universite de Caen, LPC, IN2P3-CNRS, Caen-Cedex (France); Ademard, G.; Borderie, B.; Edelbruck, P.; Rivet, M.F.; Salomon, F. [Universite Paris-Sud 11, Institut de Physique Nucleaire, CNRS/IN2P3, Orsay cedex (France); Bonnet, E.; Chbihi, A.; Frankland, J.D.; Gruyer, D. [CEA/DSM-CNRS/IN2P3, GANIL, B.P. 5027, Caen cedex (France); Casini, G.; Olmi, A.; Piantelli, S. [INFN, Sezione di Firenze, Sesto Fiorentino (Italy); Cinausero, M.; Gramegna, F.; Marchi, T. [INFN-LNL Legnaro, Legnaro (Padova) (Italy); Duenas, J.A. [FCCEE Universidad de Huelva, Departamento de Fisica Aplicada, Huelva (Spain); Kordyasz, A. [University of Warsaw, Heavy Ion Laboratory, Warsaw (Poland); Kozik, T.; Twarog, T. [Institute of Nuclear Physics IFJ-PAN, Jagiellonian University, Krakow (Poland); Morelli, L. [INFN, Bologna (Italy); Universita di Bologna, Bologna (Italy); Ordine, A. [INFN, Sezione di Napoli, Napoli (Italy); Parlog, M. [ENSICAEN et Universite de Caen, LPC, IN2P3-CNRS, Caen-Cedex (France); ' ' Horia Hulubei' ' National Institute of Physics and Nuclear Engineering, Bucharest (Romania); Rosato, E.; Spadaccini, G. [INFN, Sezione di Napoli, Napoli (Italy); Universita di Napoli ' ' Federico II' ' , Dipartimento di Fisica, Napoli (Italy); Alba, R.; Maiolino, C.; Santonocito, D. [INFN-LNS Catania, Catania (Italy); Collaboration: FAZIA Collaboration

    2014-05-15

    A study of identification properties of a Si-Si ΔE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated with a depleted layer ranging from 90% to 60% of the detector thickness. Fragment identification has been performed using either the ΔE-E technique or the Pulse Shape Analysis (PSA). Both detectors are reverse mounted: particles enter from the low field side, to enhance the PSA performance. The achieved charge and mass resolution has been quantitatively expressed using a Figure of Merit (FoM). Charge collection efficiency has been evaluated and the possibility of energy calibration corrections has been considered. We find that the ΔE-E performance is not affected by incomplete depletion even when only 60% of the wafer is depleted. Isotopic separation capability improves at lower bias voltages with respect to full depletion, though charge identification thresholds are higher than at full depletion. Good isotopic identification via PSA has been obtained from a partially depleted detector, whose doping uniformity is not good enough for isotopic identification at full depletion. (orig.)

  9. Evaluation efficiency for mobile as discharge measurement device for partially filled circular channel

    Directory of Open Access Journals (Sweden)

    I.M.H. Rashwan

    2013-06-01

    Full Text Available Discharge measurement is an important step in engineering applications such as sewerage system, irrigation and drainage system. Mobile flume is a simple and low-cost discharge measuring device constructed of two pieces of pipes, one installed vertically inside the other. The circular mobile flume depends on the concept of developing a contracted zone to have a control section. To evaluate the efficiency of this type of device mathematical and experimental studies are presented. Specific energy, discharge and Froude number equations are used to develop mathematical model. Experimental work is carried out to measure the discharge values corresponding to the specific energy values. The experimental data is used to evaluate the mobile flume as a device to measure discharge. A new equation for the discharge coefficient is presented. This equation can be used to determined accurate discharge with knowing the contraction ratio and measured specific energy.

  10. Anthropometric body measurements based on multi-view stereo image reconstruction.

    Science.gov (United States)

    Li, Zhaoxin; Jia, Wenyan; Mao, Zhi-Hong; Li, Jie; Chen, Hsin-Chen; Zuo, Wangmeng; Wang, Kuanquan; Sun, Mingui

    2013-01-01

    Anthropometric measurements, such as the circumferences of the hip, arm, leg and waist, waist-to-hip ratio, and body mass index, are of high significance in obesity and fitness evaluation. In this paper, we present a home based imaging system capable of conducting anthropometric measurements. Body images are acquired at different angles using a home camera and a simple rotating disk. Advanced image processing algorithms are utilized for 3D body surface reconstruction. A coarse body shape model is first established from segmented body silhouettes. Then, this model is refined through an inter-image consistency maximization process based on an energy function. Our experimental results using both a mannequin surrogate and a real human body validate the feasibility of the proposed system.

  11. Measuring cues for stand-off deception detection based on full-body nonverbal features in body-worn cameras

    Science.gov (United States)

    Bouma, Henri; Burghouts, Gertjan; den Hollander, Richard; van der Zee, Sophie; Baan, Jan; ten Hove, Johan-Martijn; van Diepen, Sjaak; van den Haak, Paul; van Rest, Jeroen

    2016-10-01

    Deception detection is valuable in the security domain to distinguish truth from lies. It is desirable in many security applications, such as suspect and witness interviews and airport passenger screening. Interviewers are constantly trying to assess the credibility of a statement, usually based on intuition without objective technical support. However, psychological research has shown that humans can hardly perform better than random guessing. Deception detection is a multi-disciplinary research area with an interest from different fields, such as psychology and computer science. In the last decade, several developments have helped to improve the accuracy of lie detection (e.g., with a concealed information test, increasing the cognitive load, or measurements with motion capture suits) and relevant cues have been discovered (e.g., eye blinking or fiddling with the fingers). With an increasing presence of mobile phones and bodycams in society, a mobile, stand-off, automatic deception detection methodology based on various cues from the whole body would create new application opportunities. In this paper, we study the feasibility of measuring these visual cues automatically on different parts of the body, laying the groundwork for stand-off deception detection in more flexible and mobile deployable sensors, such as body-worn cameras. We give an extensive overview of recent developments in two communities: in the behavioral-science community the developments that improve deception detection with a special attention to the observed relevant non-verbal cues, and in the computer-vision community the recent methods that are able to measure these cues. The cues are extracted from several body parts: the eyes, the mouth, the head and the fullbody pose. We performed an experiment using several state-of-the-art video-content-analysis (VCA) techniques to assess the quality of robustly measuring these visual cues.

  12. Probabilistic teleportation via multi-parameter measurements and partially entangled states

    Science.gov (United States)

    Wei, Jiahua; Shi, Lei; Han, Chen; Xu, Zhiyan; Zhu, Yu; Wang, Gang; Wu, Hao

    2018-04-01

    In this paper, a novel scheme for probabilistic teleportation is presented with multi-parameter measurements via a non-maximally entangled state. This is in contrast to the fact that the measurement kinds for quantum teleportation are usually particular in most previous schemes. The detail implementation producers for our proposal are given by using of appropriate local unitary operations. Moreover, the total success probability and classical information of this proposal are calculated. It is demonstrated that the success probability and classical cost would be changed with the multi-measurement parameters and the entanglement factor of quantum channel. Our scheme could enlarge the research range of probabilistic teleportation.

  13. State-of-the-art measurements in human body composition: A moving frontier of clinical importance

    Science.gov (United States)

    Gallagher, D.; Shaheen, I.; Zafar, K.

    2010-01-01

    The measurement of human body composition allows for the estimation of body tissues, organs, and their distributions in living persons without inflicting harm. From a nutritional perspective, the interest in body composition has increased multi-fold with the global increase in the prevalence of obesity and its complications. The latter has driven in part the need for improved measurement methods with greater sensitivity and precision. There is no single gold standard for body-composition measurements in-vivo. All methods incorporate assumptions that do not apply in all individuals and the more accurate models are derived by using a combination of measurements, thereby reducing the importance of each assumption. This review will discuss why the measurement of body composition or human phenotyping is important; discuss new areas where the measurement of body composition (human phenotyping) is recognized as having important application; and will summarize recent advances made in new methodology. Reference will also be made to areas we cannot yet measure due to the lack of appropriate measurement methodologies, most especially measurements methods that provide information on kinetic states (not just static state) and metabolic function. PMID:21234275

  14. Measurements of the total-body potassium contents. Application of reference value with the whole-body counter

    International Nuclear Information System (INIS)

    Yamamoto, Tetsuo; Saegusa, Kenji; Arimizu, Noboru; Kuniyasu, Yoshio; Itoh, Hisao

    2001-01-01

    The total-body potassium contents were measured in 405 healthy volunteers and 186 patients with whole body counter in Chiba University Hospital. The total-body potassium contents was expressed by the reference value (R value). The R value was calculated as measured potassium contents (g) divided by the body surface area (m 2 ) and adjusted by age and sex of healthy persons. The R value was 100.65±9.22% in 405 healthy volunteers. Those of each disease were as follows: liver cirrhosis; 94.24±11.22%, chronic hepatitis; 95.74±11.24%, hyperthyroidism; 99.37±10.8%, periodic paralysis; 82.0±9.01%, Barter's syndrome; 93.99±9.86%, myasthenia gravis; 97.34±6.42% and hypo-potassemia; 90.64±11.76%, respectively. The R values of other diseases such as uterine cancer, breast cancer, anemia, hypertension were 97.78±11.5%, 99.22±8.88%, 96.64±12.73%, 98.5±9.63% respectively. Fourteen patients showed especially lower R values under 75%. These were 1 liver cirrhosis, 3 hypertension, 1 diabetes mellitus, 3 hypo-potassemia, 1 periodic paralysis, 2 Barter's syndrome, 2 chemical poisoning, and 1 breast cancer. Follow-up study was performed in some patients with the lower R values. The result of follow-up study showed that there was a relationship between improvement of symptoms and increase of total body potassium contents. (author)

  15. Measurements of the Z partial decay width into c anti c and multiplicity of charm quarks per b decay

    International Nuclear Information System (INIS)

    Abreu, P.; Adam, W.; Adye, T.

    2000-01-01

    The partial decay width R c of the Z into c anti c quark pair and the number of charm quarks n c per b decay are measured with the DELPHI detector at LEP 1. Particle identification provides clear D 0 , D + , D s + and Λ c + signatures. The charm hadron production rate is measured in each channel by a fit to the scaled energy, impact parameter information and the invariant mass spectrum. Two measurements of R c are presented, from the D *+ production rate and from the overall charm counting, including strange charm baryon production, in c anti c events. The multiplicity n c , which includes hidden c anti c and strange charm baryon production, is inferred from the charm counting in b anti b events. The final results are R c =0.1665±0.0095 and n c =1.166±0.086. (orig.)

  16. Dietary restraint partially mediates the relationship between impulsivity and binge eating only in lean individuals: The importance of accounting for body mass in studies of restraint

    Directory of Open Access Journals (Sweden)

    Jaime Ashley Coffino

    2016-10-01

    Full Text Available Binge eating is characteristic of eating and weight-related disorders such as binge eating disorder, bulimia nervosa, and obesity. In light of data that suggests impulsivity is associated with overeating specifically in restrained eaters, this study sought to elucidate the exact nature of the associations between these variables, hypothesizing that the relationship between impulsivity and binge eating is mediated by restrained eating. We further hypothesized that the role of dietary restraint as a mediator would be moderated by body mass index (BMI. Study participants (n = 506, 50.6% female were categorized based on self-reported BMI as under- and normal weight (BMI < 25, 65.8%, n = 333 or overweight and obese (BMI ≥ 25, 34.2%, n = 173 and completed the restrained eating subscale of the Dutch Eating Behavior Questionnaire, the difficulties with impulse control subscale of the Difficulties with Emotion Regulation Scale, and the Binge Eating Scale. Findings provide initial evidence for the hypothesized moderated mediation model, with dietary restraint partially mediating the relationship between impulsivity and binge eating severity only in lean respondents. In respondents with overweight or obesity, impulsivity was significantly correlated with binge eating severity, but dietary restraint was not. Findings inform our conceptualization of dietary restraint as a possible risk factor for binge eating and highlight the importance of accounting for body mass in research on the impact of dietary restraint on eating behaviors.

  17. Non-contact measurement of partial gas pressure and distribution of elemental composition using energy-resolved neutron imaging

    Directory of Open Access Journals (Sweden)

    A. S. Tremsin

    2017-01-01

    Full Text Available Neutron resonance absorption imaging is a non-destructive technique that can characterize the elemental composition of a sample by measuring nuclear resonances in the spectrum of a transmitted beam. Recent developments in pixelated time-of-flight imaging detectors coupled with pulsed neutron sources pose new opportunities for energy-resolved imaging. In this paper we demonstrate non-contact measurements of the partial pressure of xenon and krypton gases encapsulated in a steel pipe while simultaneously passing the neutron beam through high-Z materials. The configuration was chosen as a proof of principle demonstration of the potential to make non-destructive measurement of gas composition in nuclear fuel rods. The pressure measured from neutron transmission spectra (∼739 ± 98 kPa and ∼751 ± 154 kPa for two Xe resonances is in relatively good agreement with the pressure value of ∼758 ± 21 kPa measured by a pressure gauge. This type of imaging has been performed previously for solids with a spatial resolution of ∼ 100 μm. In the present study it is demonstrated that the high penetration capability of epithermal neutrons enables quantitative mapping of gases encapsulate within high-Z materials such as steel, tungsten, urania and others. This technique may be beneficial for the non-destructive testing of bulk composition of objects (such as spent nuclear fuel assemblies and others containing various elements opaque to other more conventional imaging techniques. The ability to image the gaseous substances concealed within solid materials also allows non-destructive leak testing of various containers and ultimately measurement of gas partial pressures with sub-mm spatial resolution.

  18. Monte Carlo study of thermal flux profiles and body correction factors for body protein measurements of obese subjects

    International Nuclear Information System (INIS)

    McGregor, B.J.; Allen, B.J.

    1991-01-01

    In previous calculations for total body nitrogen measurements of children, the anterior/posterior thermal neutron flux profile with depth was found to be fairly flat after an initial rise. However, for obese adults significant variations are found in the flux profile with the central flux value being as low as 20% of the peak value. The significance of these flux variations is examined. Correction factors are calculated for the varying attenuation of the nitrogen and hydrogen photons by a range of obese bodies. The calculations included the effect of the thermal flux profile as well as that of an outer layer of low nitrogen content adipose tissue. The bodies are assumed to have a homogeneous hydrogen content. A study of four obese body models with varying sex and fat content shows that the correction factors do not vary much between males and females. This is surprising since the female models are assumed to have a surface fat layer twice as thick as for the male models. The correction factors are found to be only slightly sensitive to the thermal flux variations with depth. 5 refs., 1 tab., 4 figs

  19. Triceps skin fold thickness as a measure of body fat in Nigerian ...

    African Journals Online (AJOL)

    Background: Skin fold thickness (SFT) at selected areas offers a simple method of subcutaneous fat assessment and provides a good estimate of obesity and body fat distribution. The triceps SFT has been shown to be one of the best and most popular sites for SFT measurement in children. Objective: To assess the body fat ...

  20. Weights and linear measurements of the body and some organs of ...

    African Journals Online (AJOL)

    The absolute weights of the body, heart, kidneys, spleen, pancreas, liver, gonads, digestive tract and adrenal glands, as well as the absolute linear measurements of the body, digestive tract and oviduct were determined in adult female and male African white-bellied tree pangolins. The relative weights, relative lengths and ...

  1. Body conscious? Interoceptive awareness, measured by heartbeat perception, is negatively correlated with self-objectification.

    Science.gov (United States)

    Ainley, Vivien; Tsakiris, Manos

    2013-01-01

    'Self-objectification' is the tendency to experience one's body principally as an object, to be evaluated for its appearance rather than for its effectiveness. Within objectification theory, it has been proposed that self-objectification accounts for the poorer interoceptive awareness observed in women, as measured by heartbeat perception. Our study is, we believe, the first specifically to test this relationship. Using a well-validated and reliable heartbeat perception task, we measured interoceptive awareness in women and compared this with their scores on the Self-Objectification Questionnaire, the Self-Consciousness Scale and the Body Consciousness Questionnaire. Interoceptive awareness was negatively correlated with self-objectification. Interoceptive awareness, public body consciousness and private body consciousness together explained 31% of the variance in self-objectification. However, private body consciousness was not significantly correlated with interoceptive awareness, which may explain the many nonsignificant results in self-objectification studies that have used private body consciousness as a measure of body awareness. We propose interoceptive awareness, assessed by heartbeat perception, as a measure of body awareness in self-objectification studies. Our findings have implications for those clinical conditions, in women, which are characterised by self-objectification and low interoceptive awareness, such as eating disorders.

  2. Body conscious? Interoceptive awareness, measured by heartbeat perception, is negatively correlated with self-objectification.

    Directory of Open Access Journals (Sweden)

    Vivien Ainley

    Full Text Available BACKGROUND: 'Self-objectification' is the tendency to experience one's body principally as an object, to be evaluated for its appearance rather than for its effectiveness. Within objectification theory, it has been proposed that self-objectification accounts for the poorer interoceptive awareness observed in women, as measured by heartbeat perception. Our study is, we believe, the first specifically to test this relationship. METHODOLOGY/PRINCIPAL FINDINGS: Using a well-validated and reliable heartbeat perception task, we measured interoceptive awareness in women and compared this with their scores on the Self-Objectification Questionnaire, the Self-Consciousness Scale and the Body Consciousness Questionnaire. Interoceptive awareness was negatively correlated with self-objectification. Interoceptive awareness, public body consciousness and private body consciousness together explained 31% of the variance in self-objectification. However, private body consciousness was not significantly correlated with interoceptive awareness, which may explain the many nonsignificant results in self-objectification studies that have used private body consciousness as a measure of body awareness. CONCLUSIONS/SIGNIFICANCE: We propose interoceptive awareness, assessed by heartbeat perception, as a measure of body awareness in self-objectification studies. Our findings have implications for those clinical conditions, in women, which are characterised by self-objectification and low interoceptive awareness, such as eating disorders.

  3. Partial Sleep Deprivation Attenuates the Positive Affective System: Effects Across Multiple Measurement Modalities.

    Science.gov (United States)

    Finan, Patrick H; Quartana, Phillip J; Remeniuk, Bethany; Garland, Eric L; Rhudy, Jamie L; Hand, Matthew; Irwin, Michael R; Smith, Michael T

    2017-01-01

    Ample behavioral and neurobiological evidence links sleep and affective functioning. Recent self-report evidence suggests that the affective problems associated with sleep loss may be stronger for positive versus negative affective state and that those effects may be mediated by changes in electroencepholographically measured slow wave sleep (SWS). In the present study, we extend those preliminary findings using multiple measures of affective functioning. In a within-subject randomized crossover experiment, we tested the effects of one night of sleep continuity disruption via forced awakenings (FA) compared to one night of uninterrupted sleep (US) on three measures of positive and negative affective functioning: self-reported affective state, affective pain modulation, and affect-biased attention. The study was set in an inpatient clinical research suite. Healthy, good sleeping adults (N = 45) were included. Results indicated that a single night of sleep continuity disruption attenuated positive affective state via FA-induced reductions in SWS. Additionally, sleep continuity disruption attenuated the inhibition of pain by positive affect as well as attention bias to positive affective stimuli. Negative affective state, negative affective pain facilitation, nor negative attention bias were altered by sleep continuity disruption. The present findings, observed across multiple measures of affective function, suggest that sleep continuity disruption has a stronger influence on the positive affective system relative to the negative affective affective system. © Sleep Research Society 2016. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  4. Regional alveolar partial pressure of oxygen measurement with parallel accelerated hyperpolarized gas MRI.

    Science.gov (United States)

    Kadlecek, Stephen; Hamedani, Hooman; Xu, Yinan; Emami, Kiarash; Xin, Yi; Ishii, Masaru; Rizi, Rahim

    2013-10-01

    Alveolar oxygen tension (Pao2) is sensitive to the interplay between local ventilation, perfusion, and alveolar-capillary membrane permeability, and thus reflects physiologic heterogeneity of healthy and diseased lung function. Several hyperpolarized helium ((3)He) magnetic resonance imaging (MRI)-based Pao2 mapping techniques have been reported, and considerable effort has gone toward reducing Pao2 measurement error. We present a new Pao2 imaging scheme, using parallel accelerated MRI, which significantly reduces measurement error. The proposed Pao2 mapping scheme was computer-simulated and was tested on both phantoms and five human subjects. Where possible, correspondence between actual local oxygen concentration and derived values was assessed for both bias (deviation from the true mean) and imaging artifact (deviation from the true spatial distribution). Phantom experiments demonstrated a significantly reduced coefficient of variation using the accelerated scheme. Simulation results support this observation and predict that correspondence between the true spatial distribution and the derived map is always superior using the accelerated scheme, although the improvement becomes less significant as the signal-to-noise ratio increases. Paired measurements in the human subjects, comparing accelerated and fully sampled schemes, show a reduced Pao2 distribution width for 41 of 46 slices. In contrast to proton MRI, acceleration of hyperpolarized imaging has no signal-to-noise penalty; its use in Pao2 measurement is therefore always beneficial. Comparison of multiple schemes shows that the benefit arises from a longer time-base during which oxygen-induced depolarization modifies the signal strength. Demonstration of the accelerated technique in human studies shows the feasibility of the method and suggests that measurement error is reduced here as well, particularly at low signal-to-noise levels. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  5. Measuring body composition in overweight individuals by dual energy x-ray absorptiometry

    International Nuclear Information System (INIS)

    Brownbill, Rhonda A; Ilich, Jasminka Z

    2005-01-01

    Dual energy x-ray absorptiometry (DXA) is widely used for body composition measurements in normal-weight and overweight/obese individuals. The limitations of bone densitometers have been frequently addressed. However, the possible errors in assessing body composition in overweight individuals due to incorrect positioning or limitations of DXA to accurately assess both bone mineral density and body composition in obese individuals have not received much attention and are the focus of this report. We discuss proper ways of measuring overweight individuals and point to some studies where that might not have been the case. It appears that currently, the most prudent approach to assess body composition of large individuals who cannot fit under the scanning area would be to estimate regional fat, namely the regions of thigh and/or abdomen. Additionally, using two-half body scans, although time consuming, may provide a relatively accurate measurement of total body fat, however, more studies using this technique are needed to validate it. Researchers using bone densitometers for body composition measurements need to have an understanding of its limitations in overweight individuals and address them appropriately when interpreting their results. Studies on accuracy and precision in measurements of both bone and soft tissue composition in overweight individuals using available densitometers are needed

  6. Validation of bioelectrical-impedance analysis as a measurement of change in body composition in obesity

    International Nuclear Information System (INIS)

    Kushner, R.F.; Kunigk, A.; Alspaugh, M.; Andronis, P.T.; Leitch, C.A.; Schoeller, D.A.

    1990-01-01

    The bioelectrical-impedance-analysis (BIA) method accurately measures body composition in weight-stable subjects. This study validates the use of BIA to measure change in body composition. Twelve obese females underwent weight loss at a mean rate of 1.16 kg/wk. Body composition was measured by deuterium oxide dilution (D2O), BIA, and skinfold anthropometry (SFA) at baseline and at 5% decrements in weight. Highly significant correlations were obtained between D2O and BIA (r = 0.971) and between D2O and SFA (r = 0.932). Overall, BIA predicted change in fat-free mass with greater accuracy (to 0.4 kg) and precision (+/- 1.28 kg) than did anthropometry (to 0.8 kg and +/- 2.58 kg, respectively). We conclude that BIA is a useful clinical method for measuring change in body composition

  7. Rate estimation in partially observed Markov jump processes with measurement errors

    OpenAIRE

    Amrein, Michael; Kuensch, Hans R.

    2010-01-01

    We present a simulation methodology for Bayesian estimation of rate parameters in Markov jump processes arising for example in stochastic kinetic models. To handle the problem of missing components and measurement errors in observed data, we embed the Markov jump process into the framework of a general state space model. We do not use diffusion approximations. Markov chain Monte Carlo and particle filter type algorithms are introduced, which allow sampling from the posterior distribution of t...

  8. A nonintrusive temperature measuring system for estimating deep body temperature in bed.

    Science.gov (United States)

    Sim, S Y; Lee, W K; Baek, H J; Park, K S

    2012-01-01

    Deep body temperature is an important indicator that reflects human being's overall physiological states. Existing deep body temperature monitoring systems are too invasive to apply to awake patients for a long time. Therefore, we proposed a nonintrusive deep body temperature measuring system. To estimate deep body temperature nonintrusively, a dual-heat-flux probe and double-sensor probes were embedded in a neck pillow. When a patient uses the neck pillow to rest, the deep body temperature can be assessed using one of the thermometer probes embedded in the neck pillow. We could estimate deep body temperature in 3 different sleep positions. Also, to reduce the initial response time of dual-heat-flux thermometer which measures body temperature in supine position, we employed the curve-fitting method to one subject. And thereby, we could obtain the deep body temperature in a minute. This result shows the possibility that the system can be used as practical temperature monitoring system with appropriate curve-fitting model. In the next study, we would try to establish a general fitting model that can be applied to all of the subjects. In addition, we are planning to extract meaningful health information such as sleep structure analysis from deep body temperature data which are acquired from this system.

  9. Body fat and blood pressure: comparison of blood pressure measurements in Chinese children with different body fat levels.

    Science.gov (United States)

    Ma, Jun; Wang, Zhiqiang; Dong, Bin; Song, Yi; Hu, Peijin; Zhang, Bing

    2012-11-14

    Children in China are experiencing a rapid increase in the prevalence of obesity, which is associated with hypertension. To compare the effect of body fat on blood pressure (BP) with that of the normal physical growth, we compared BP levels in Chinese children with different body fat levels. In the present population-based study, 13 972 children in the highest-skinfold-thickness-quartile group were individually matched to 13 972 children in the lowest-skinfold-thickness-quartile group by height and weight. Similarly, 5103 children in the highest-waist-circumference-quartile group were matched to the same number of children in the lowest-waist-circumference-quartile group. The high- and low-fat groups had similar height and weight but the high-fat group had significantly higher skinfold and waist circumference measurements. The differences in systolic BP (SBP) between the high- and low-skinfold-thickness groups were small: 0·01 (95 % CI -0·41, 0·44) mmHg in boys and 0·20 (95 % CI -0·15, 0·54) mmHg in girls. The differences in diastolic BP (DBP) were also small (0·39 and 0·38 mmHg for boys and girls, respectively) but were statistically significant. The differences in both SBP and DBP between the high- and low-waist-circumference groups were small but not statistically significant. For a given body size as measured by height and weight, relative body fat had little impact on BP levels in these children. Fat mass and lean mass may have a similar quantitative impact on BP in healthy-weight children.

  10. Evaluation of electrical broad bandwidth impedance spectroscopy as a tool for body composition measurement in cows in comparison with body measurements and the deuterium oxide dilution method.

    Science.gov (United States)

    Schäff, C T; Pliquett, U; Tuchscherer, A; Pfuhl, R; Görs, S; Metges, C C; Hammon, H M; Kröger-Koch, C

    2017-05-01

    Body fatness and degree of body fat mobilization in cows vary enormously during their reproduction cycle and influence energy partitioning and metabolic adaptation. The objective of the study was to test bioelectrical impedance spectroscopy (BIS) as a method for predicting fat depot mass (FDM), in living cows. The FDM is defined as the sum of subcutaneous, omental, mesenteric, retroperitoneal, and carcass fat mass. Bioelectrical impedance spectroscopy is compared with the prediction of FDM from the deuterium oxide (DO) dilution method and from body conformation measurements. Charolais × Holstein Friesian (HF; = 18; 30 d in milk) crossbred cows and 2 HF (lactating and nonlactating) cows were assessed by body conformation measurements, BIS, and the DO dilution method. The BCS of cows was a mean of 3.68 (SE 0.64). For the DO dilution method, a bolus of 0.23 g/kg BW DO (60 atom%) was intravenously injected and deuterium (D) enrichment was analyzed in plasma and whey by stabile isotope mass spectrometry, and total body water content was calculated. Impedance measurement was performed using a 4-electrode interface and time domain-based measurement system consisting of a voltage/current converter for applying current stimulus and an amplifier for monitoring voltage across the sensor electrodes. For the BIS, we used complex impedances over three frequency decades that delivers information on intra- and extracellular water and capacity of cell membranes. Impedance data (resistance of extra- and intracellular space, cell membrane capacity, and phase angle) were extracted 1) by simple curve fit to extract the resistance at direct current and high frequency and 2) by using an electrical equivalent circuit. Cows were slaughtered 7 d after BIS and D enrichment measurements and dissected for the measurement of FDM. Multiple linear regression analyses were performed to predict FDM based on data obtained from body conformation measurements, BIS, and D enrichment, and applied

  11. Measurements of Radioactivity in Body Organs. Report of a Panel of Experts

    International Nuclear Information System (INIS)

    1970-01-01

    Measurements of radioactivity in body organs in vivo entail physical and other problems which do not arise in measurements of radioactivity in vitro. From 8-12 December 1969 the International Atomic Energy Agency convened at its Headquarters in Vienna a panel of experts to review the existing status of techniques for such measurements

  12. Measurement of the partial widths of the Z into up- and down-type quarks

    CERN Document Server

    Abbiendi, G.; Akesson, P.F.; Alexander, G.; Allison, John; Amaral, P.; Anagnostou, G.; Anderson, K.J.; Arcelli, S.; Asai, S.; Axen, D.; Azuelos, G.; Bailey, I.; Barberio, E.; Barillari, T.; Barlow, R.J.; Batley, R.J.; Bechtle, P.; Behnke, T.; Bell, Kenneth Watson; Bell, P.J.; Bella, G.; Bellerive, A.; Benelli, G.; Bethke, S.; Biebel, O.; Boeriu, O.; Bock, P.; Boutemeur, M.; Braibant, S.; Brigliadori, L.; Brown, Robert M.; Buesser, K.; Burckhart, H.J.; Campana, S.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, D.G.; Ciocca, C.; Csilling, A.; Cuffiani, M.; Dado, S.; De Roeck, A.; De Wolf, E.A.; Desch, K.; Dienes, B.; Donkers, M.; Doucet, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Etzion, E.; Fabbri, F.; Feld, L.; Ferrari, P.; Fiedler, F.; Fleck, I.; Ford, M.; Frey, A.; Gagnon, P.; Gary, John William; Gaycken, G.; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Giunta, Marina; Goldberg, J.; Gross, E.; Grunhaus, J.; Gruwe, M.; Gunther, P.O.; Gupta, A.; Hajdu, C.; Hamann, M.; Hanson, G.G.; Harel, A.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herten, G.; Heuer, R.D.; Hill, J.C.; Hoffman, Kara Dion; Horvath, D.; Huntemeyer, P.; Igo-Kemenes, P.; Ishii, K.; Jeremie, H.; Jovanovic, P.; Junk, T.R.; Kanaya, N.; Kanzaki, J.; Karlen, D.; Kawagoe, K.; Kawamoto, T.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Klein, K.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Komamiya, S.; Kramer, T.; Krieger, P.; von Krogh, J.; Kruger, K.; Kuhl, T.; Kupper, M.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Layter, J.G.; Lellouch, D.; Lettso, J.; Levinson, L.; Lillich, J.; Lloyd, S.L.; Loebinger, F.K.; Lu, J.; Ludwig, A.; Ludwig, J.; Mader, W.; Marcellini, S.; Martin, A.J.; Masetti, G.; Mashimo, T.; Mattig, Peter; McKenna, J.; McPherson, R.A.; Meijers, F.; Menges, W.; Merritt, F.S.; Mes, H.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Moed, S.; Mohr, W.; Mori, T.; Mutter, A.; Nagai, K.; Nakamura, I.; Nanjo, H.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oh, A.; Okpara, A.; Oreglia, M.J.; Orito, S.; Pahl, C.; Pasztor, G.; Pater, J.R.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poli, B.; Pooth, O.; Przybycien, M.; Quadt, A.; Rabbertz, K.; Rembser, C.; Renkel, P.; Roney, J.M.; Rosati, S.; Rozen, Y.; Runge, K.; Sachs, K.; Saeki, T.; Sarkisyan, E.K.G.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schoerner-Sadenius, Thomas; Schroder, Matthias; Schumacher, M.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Sherwood, P.; Skuja, A.; Smith, A.M.; Sobie, R.; Soldner-Rembold, S.; Spano, F.; Stahl, A.; Strom, David M.; Strohmer, R.; Tarem, S.; Tasevsky, M.; Teuscher, R.; Thomson, M.A.; Torrence, E.; Toya, D.; Tran, P.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Ujvari, B.; Vollmer, C.F.; Vannerem, P.; Vertesi, R.; Verzocchi, M.; Voss, H.; Vossebeld, J.; Waller, D.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wengler, T.; Wermes, N.; Wetterling, D.; Wilson, G.W.; Wilson, J.A.; Wolf, G.; Wyatt, T.R.; Yamashita, S.; Zer-Zion, D.; Zivkovic, Lidija

    2004-01-01

    Using the entire OPAL LEP1 on-peak Z hadronic decay sample, Z -> qbarq gamma decays were selected by tagging hadronic final states with isolated photon candidates in the electromagnetic calorimeter. Combining the measured rates of Z -> qbarq gamma decays with the total rate of hadronic Z decays permits the simultaneous determination of the widths of the Z into up- and down-type quarks. The values obtained, with total errors, were Gamma u = 300 ^{+19}_{-18} MeV and Gamma d = 381 ^{+12}_{-12} MeV. The results are in good agreement with the Standard Model expectation.

  13. Analysis of measured data of human body based on error correcting frequency

    Science.gov (United States)

    Jin, Aiyan; Peipei, Gao; Shang, Xiaomei

    2014-04-01

    Anthropometry is to measure all parts of human body surface, and the measured data is the basis of analysis and study of the human body, establishment and modification of garment size and formulation and implementation of online clothing store. In this paper, several groups of the measured data are gained, and analysis of data error is gotten by analyzing the error frequency and using analysis of variance method in mathematical statistics method. Determination of the measured data accuracy and the difficulty of measured parts of human body, further studies of the causes of data errors, and summarization of the key points to minimize errors possibly are also mentioned in the paper. This paper analyses the measured data based on error frequency, and in a way , it provides certain reference elements to promote the garment industry development.

  14. Monitoring in microvascular tissue transfer by measurement of oxygen partial pressure: four years experience with 125 microsurgical transplants.

    Science.gov (United States)

    Jonas, René; Schaal, Thomas; Krimmel, Michael; Gülicher, Dirk; Reinert, Siegmar; Hoffmann, Jürgen

    2013-06-01

    In a prospective study, the characteristics and benefit of an invasive measurement of oxygen partial pressure (pO(2)) with the aid of a polarographic sensor were investigated in 125 microsurgical reconstructions of the head and neck area over a period of 45 months. Measurements were performed over 96 h in eight different types of microsurgically revascularized flaps for extra- and intraoral reconstructions and were evaluated separately for each flap type. Of 125 reconstructions the system indicated malperfusion in 18 cases. Salvage surgery was performed in 17 cases due to venous thrombosis (6 cases), arterial thrombosis (3 cases), a combination of arterial and venous thrombosis (2 cases), rheological problems (3 cases), venous insufficiency by hematoma (2 cases) and kinking of vessels (1 case). In 10 cases salvage surgery was successful, 7 flaps were lost despite salvage surgery. In all these cases, the polarographic probe indicated the necessity of salvage surgery correctly. After 96 h no malperfusion was seen. Postoperatively, a common and characteristic development of the oxygen partial pressure in different types of flaps was seen. Initially, a clear increase of pO(2) could be measured. During 96 h, a slow decrease of pO(2) was observed. In conclusion polarographic measurement of pO(2) can be an excellent apparative supplement for the postoperative clinical control of microsurgically revascularized transplants. In buried flaps, this technique represents the only reliable method for transplant monitoring. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Comparison between auricular and standard rectal thermometers for the measurement of body temperature in dogs.

    Science.gov (United States)

    Sousa, Marlos G; Carareto, Roberta; Pereira-Junior, Valdo A; Aquino, Monally C C

    2011-04-01

    Although the rectal mucosa remains the traditional site for measuring body temperature in dogs, an increasing number of clinicians have been using auricular temperature to estimate core body temperature. In this study, 88 mature healthy dogs had body temperatures measured with auricular and rectal thermometers. The mean temperature and confidence intervals were similar for each method, but Bland-Altman plots showed high biases and limits of agreement unacceptable for clinical purposes. The results indicate that auricular and rectal temperatures should not be interpreted interchangeably.

  16. An Evaluation of pectus excavatum by means of body surface measurements on chest CT scans

    International Nuclear Information System (INIS)

    Hirotani, Taichi; Ohama, Kazunori; Shimotake, Takashi; Ishikawa, Nobuki; Watanabe, Reiji

    2009-01-01

    The aim of this study is to determine whether the body surface index replaces the Haller index in order to evaluate the severity of pectus excavatum. Sixty-nine cases with a diagnosis of pectus excavatum between August 2001 and January 2008 were prospectively enrolled in the study. The anterior-posterior chest dimension, lateral chest dimension and depth of the most profound depressed area were measured. The body surface index was expressed as an equation A/(B-C), where A was the transverse diameter, B was the anterior-posterior diameter and C was the depth of the depressed area. This index was compared to the Haller index in each patient. In this study, each value was measured on a chest CT scan. The body surface index significantly correlated with the Haller index, in which the coefficient of correlation was 0.879 (p<0.01). The body surface index corresponding to Haller index 3.25 seems to be 1.67. We could find the body surface index corresponding to each Haller index. We propose that an evaluation of pectus excavatum by means of body surface measurements is clinically useful, and may replace the Haller index. The body surface index may allow us to assess the severity of pectus excavatum without a CT scan, resulting in a reduction of radiation exposure for children with pectus excavatum. It's possible to evaluate the body surface index by using a relational table between this index and the Hailer index. We'll evaluate the body surface index by using values measured on a real body. (author)

  17. Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation

    International Nuclear Information System (INIS)

    Rahimi, Asal; Thomas, Kimberly; Spangler, Ann; Rao, Roshni; Leitch, Marilyn; Wooldridge, Rachel; Rivers, Aeisha; Seiler, Stephen; Albuquerque, Kevin; Stevenson, Stella; Goudreau, Sally; Garwood, Dan; Haley, Barbara; Euhus, David; Heinzerling, John; Ding, Chuxiong; Gao, Ang; Ahn, Chul; Timmerman, Robert

    2017-01-01

    Purpose: To evaluate the tolerability of a dose-escalated 5-fraction stereotactic body radiation therapy for partial-breast irradiation (S-PBI) in treating early-stage breast cancer after partial mastectomy; the primary objective was to escalate dose utilizing a robotic stereotactic radiation system treating the lumpectomy cavity without exceeding the maximum tolerated dose. Methods and Materials: Eligible patients included those with ductal carcinoma in situ or invasive nonlobular epithelial histologies and stage 0, I, or II, with tumor size <3 cm. Patients and physicians completed baseline and subsequent cosmesis outcome questionnaires. Starting dose was 30 Gy in 5 fractions and was escalated by 2.5 Gy total for each cohort to 40 Gy. Results: In all, 75 patients were enrolled, with a median age of 62 years. Median follow-up for 5 cohorts was 49.9, 42.5, 25.7, 20.3, and 13.5 months, respectively. Only 3 grade 3 toxicities were experienced. There was 1 dose-limiting toxicity in the overall cohort. Ten patients experienced palpable fat necrosis (4 of which were symptomatic). Physicians scored cosmesis as excellent or good in 95.9%, 100%, 96.7%, and 100% at baseline and 6, 12, and 24 months after S-PBI, whereas patients scored the same periods as 86.5%, 97.1%, 95.1%, and 95.3%, respectively. The disagreement rates between MDs and patients during those periods were 9.4%, 2.9%, 1.6%, and 4.7%, respectively. There have been no recurrences or distant metastases. Conclusion: Dose was escalated to the target dose of 40 Gy in 5 fractions, with the occurrence of only 1 dose-limiting toxicity. Patients felt cosmetic results improved within the first year after surgery and stereotactic body radiation therapy. Our results show minimal toxicity with excellent cosmesis; however, further follow-up is warranted in future studies. This study is the first to show the safety, tolerability, feasibility, and cosmesis results of a 5-fraction dose-escalated S-PBI treatment for

  18. Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Rahimi, Asal, E-mail: asal.rahimi@utsouthwestern.edu [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Thomas, Kimberly; Spangler, Ann [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Rao, Roshni; Leitch, Marilyn; Wooldridge, Rachel; Rivers, Aeisha [Department of Surgery, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Seiler, Stephen [Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Albuquerque, Kevin; Stevenson, Stella [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Goudreau, Sally [Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Garwood, Dan [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Haley, Barbara [Department of Medical Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Euhus, David [Department of Surgery, Johns Hopkins University, Baltimore, Maryland (United States); Heinzerling, John [Department of Radiation Oncology, Levine Cancer Institute, Charlotte, North Carolina (United States); Ding, Chuxiong [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Gao, Ang; Ahn, Chul [Department of Statistics, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Timmerman, Robert [University of Texas Southwestern Medical Center, Dallas, Texas (United States)

    2017-05-01

    Purpose: To evaluate the tolerability of a dose-escalated 5-fraction stereotactic body radiation therapy for partial-breast irradiation (S-PBI) in treating early-stage breast cancer after partial mastectomy; the primary objective was to escalate dose utilizing a robotic stereotactic radiation system treating the lumpectomy cavity without exceeding the maximum tolerated dose. Methods and Materials: Eligible patients included those with ductal carcinoma in situ or invasive nonlobular epithelial histologies and stage 0, I, or II, with tumor size <3 cm. Patients and physicians completed baseline and subsequent cosmesis outcome questionnaires. Starting dose was 30 Gy in 5 fractions and was escalated by 2.5 Gy total for each cohort to 40 Gy. Results: In all, 75 patients were enrolled, with a median age of 62 years. Median follow-up for 5 cohorts was 49.9, 42.5, 25.7, 20.3, and 13.5 months, respectively. Only 3 grade 3 toxicities were experienced. There was 1 dose-limiting toxicity in the overall cohort. Ten patients experienced palpable fat necrosis (4 of which were symptomatic). Physicians scored cosmesis as excellent or good in 95.9%, 100%, 96.7%, and 100% at baseline and 6, 12, and 24 months after S-PBI, whereas patients scored the same periods as 86.5%, 97.1%, 95.1%, and 95.3%, respectively. The disagreement rates between MDs and patients during those periods were 9.4%, 2.9%, 1.6%, and 4.7%, respectively. There have been no recurrences or distant metastases. Conclusion: Dose was escalated to the target dose of 40 Gy in 5 fractions, with the occurrence of only 1 dose-limiting toxicity. Patients felt cosmetic results improved within the first year after surgery and stereotactic body radiation therapy. Our results show minimal toxicity with excellent cosmesis; however, further follow-up is warranted in future studies. This study is the first to show the safety, tolerability, feasibility, and cosmesis results of a 5-fraction dose-escalated S-PBI treatment for

  19. Between-centre variability versus variability over time in DXA whole body measurements evaluated using a whole body phantom

    Energy Technology Data Exchange (ETDEWEB)

    Louis, Olivia [Department of Radiology, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)]. E-mail: olivia.louis@az.vub.ac.be; Verlinde, Siska [Belgian Study Group for Pediatric Endocrinology (Belgium); Thomas, Muriel [Belgian Study Group for Pediatric Endocrinology (Belgium); De Schepper, Jean [Department of Pediatrics, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)

    2006-06-15

    This study aimed to compare the variability of whole body measurements, using dual energy X-ray absorptiometry (DXA), among geographically distinct centres versus that over time in a given centre. A Hologic-designed 28 kg modular whole body phantom was used, including high density polyethylene, gray polyvinylchloride and aluminium. It was scanned on seven Hologic QDR 4500 DXA devices, located in seven centres and was also repeatedly (n = 18) scanned in the reference centre, over a time span of 5 months. The mean between-centre coefficient of variation (CV) ranged from 2.0 (lean mass) to 5.6% (fat mass) while the mean within-centre CV ranged from 0.3 (total mass) to 4.7% (total area). Between-centre variability compared well with within-centre variability for total area, bone mineral content and bone mineral density, but was significantly higher for fat (p < 0.001), lean (p < 0.005) and total mass (p < 0.001). Our results suggest that, even when using the same device, the between-centre variability remains a matter of concern, particularly where body composition is concerned.

  20. Measurement of the Time-Dependent CP Asymmetry of Partially Reconstructed B0 to D*+D*- Decays

    Energy Technology Data Exchange (ETDEWEB)

    Lees, J. P.

    2012-08-13

    We present a new measurement of the time-dependent CP asymmetry of B{sup 0} {yields}D*{sup +}D*{sup -} decays using (471 {+-} 5) million B{bar B} pairs collected with the BABAR detector at the PEP-II B Factory at the SLAC National Accelerator Laboratory. Using the technique of partial reconstruction, we measure the time-dependent CP asymmetry parameters S = -0.34 {+-} 0.12 {+-} 0.05 and C = +0:15 {+-} 0.09 {+-} 0.04. Using the value for the CP-odd fraction R{perpendicular} = 0.158 {+-} 0.028 {+-} 0.006, previously measured by BABAR with fully reconstructed B{sup 0} {yields} D{sup *+}D{sup *-} events, we extract the CP-even components S{sub +} = -0.49 {+-} 0.18 {+-} 0.07 {+-} 0.04 and C{sub +} = +0.15 {+-} 0.09 {+-} 0.04. In each case, the first uncertainty is statistical and the second is systematic; the third uncertainty on S{sub +} is the contribution from the uncertainty on R{perpendicular}. The measured value of the CP-even component S{sub +} is consistent with the value of sin 2{beta} measured in b {yields} (c{bar c})s transitions, and with the Standard Model expectation of small penguin contributions.

  1. Two-photon high-resolution measurement of partial pressure of oxygen in cerebral vasculature and tissue

    Science.gov (United States)

    Sakadžić, Sava; Roussakis, Emmanuel; Yaseen, Mohammad A.; Mandeville, Emiri T.; Srinivasan, Vivek J.; Arai, Ken; Ruvinskaya, Svetlana; Devor, Anna; Lo, Eng H.; Vinogradov, Sergei A.; Boas, David A.

    2010-01-01

    The ability to measure oxygen partial pressure (pO2) with high temporal and spatial resolution in three dimensions is crucial for understanding oxygen delivery and consumption in normal and diseased brain. Among existing pO2 measurement methods, phosphorescence quenching is optimally suited for the task. However, previous attempts to couple phosphorescence with two-photon laser scanning microscopy have faced substantial difficulties because of extremely low two-photon absorption cross-sections of conventional phosphorescent probes. Here, we report the first practical in vivo two-photon high-resolution pO2 measurements in small rodents’ cortical microvasculature and tissue, made possible by combining an optimized imaging system with a two-photon-enhanced phosphorescent nanoprobe. The method features a measurement depth of up to 250 µm, sub-second temporal resolution and requires low probe concentration. Most importantly, the properties of the probe allowed for the first direct high-resolution measurement of cortical extravascular (tissue) pO2, opening numerous possibilities for functional metabolic brain studies. PMID:20693997

  2. Two-photon high-resolution measurement of partial pressure of oxygen in cerebral vasculature and tissue.

    Science.gov (United States)

    Sakadzić, Sava; Roussakis, Emmanuel; Yaseen, Mohammad A; Mandeville, Emiri T; Srinivasan, Vivek J; Arai, Ken; Ruvinskaya, Svetlana; Devor, Anna; Lo, Eng H; Vinogradov, Sergei A; Boas, David A

    2010-09-01

    Measurements of oxygen partial pressure (pO(2)) with high temporal and spatial resolution in three dimensions is crucial for understanding oxygen delivery and consumption in normal and diseased brain. Among existing pO(2) measurement methods, phosphorescence quenching is optimally suited for the task. However, previous attempts to couple phosphorescence with two-photon laser scanning microscopy have faced substantial difficulties because of extremely low two-photon absorption cross-sections of conventional phosphorescent probes. Here we report to our knowledge the first practical in vivo two-photon high-resolution pO(2) measurements in small rodents' cortical microvasculature and tissue, made possible by combining an optimized imaging system with a two-photon-enhanced phosphorescent nanoprobe. The method features a measurement depth of up to 250 microm, sub-second temporal resolution and requires low probe concentration. The properties of the probe allowed for direct high-resolution measurement of cortical extravascular (tissue) pO(2), opening many possibilities for functional metabolic brain studies.

  3. Non-extendability of semilattice-valued measures on partially ordered sets

    CERN Document Server

    Wehrung, F

    2005-01-01

    For a distributive join-semilattice S with zero, a S-valued poset measure on a poset P is a map m:PxP->S such that m(x,z) S, for a larger poset P*, such that for all a,b in S and all x <= y in P*, m*(y,x)=avb implies that there are a positive integer n and a decomposition x=z\\_0 <= z\\_1 <= ... <= z\\_n=y in P* such that either m*(z\\_{i+1},z\\_i) <= a or m*(z\\_{i+1},z\\_i) <= b, for all i < n. In this note we prove that this is not possible as a rule, even in case the poset P we start with is a chain and S has size $\\aleph\\_1$. The proof uses a "monotone refinement property" that holds in S provided S is either a lattice, or countable, or strongly distributive, but fails for our counterexample. This strongly contrasts with the analogue problem for distances on (discrete) sets, which is known to have a positive (and even functorial) solution.

  4. Partial gamma-ray cross section measurements in 109Ag(n, x n y p gamma) reactions

    Energy Technology Data Exchange (ETDEWEB)

    Fotiadis, Nikolaos [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Devlin, Matthew James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Nelson, Ronald Owen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Carroll, James [US Army Research Laboratory, Adelphi, MD (United States)

    2015-06-02

    We report on absolute partial cross sections for production of discrete γ-rays using 109Ag(n, xnypγ) reactions with x ≤ 7 and y ≤ 1 in a total of 12 reaction channels. The data were taken using the GEANIE spectrometer comprised of 20 high-purity Ge detectors with 20 BGO escape-suppression shields. The broad-spectrum pulsed neutron beam of the Los Alamos Neutron Science Center’s (LANSCE) WNR facility provided neutrons in the energy range from 0.2 to 300 MeV. The time-of- flight technique was used to determine the incident neutron energies. Partial γ-ray cross sections have been measured for a total of 109 transitions and for neutron energies 0.8 MeV< En<300 MeV. An estimate of the population of isomers in the (n, n'), (n, 2n) and (n, 3n) channels was made.

  5. First results of total and partial cross-section measurements of the 107Ag(p,γ)108Cd reaction

    Science.gov (United States)

    Heim, Felix; Mayer, Jan; Scholz, Philipp; Spieker, Mark; Zilges, Andreas

    2018-01-01

    The γ process is assumed to play an important role in the nucleosynthesis of the majority of the p nuclei. Since the network of the γ process includes so many different reactions and - mainly unstable - nuclei, cross-section values are predominantly calculated in the scope of the Hauser-Feshbach statistical model. The values heavily depend on the nuclear-physics input parameters. The results of total and partial cross-section measurements are used to improve the accuracy of the theoretical calculations. In order to extend the experimental database, the 107Ag(p,γ)108Cd reaction was studied via the in-beam method at the high-efficiency HPGe γ-ray spectrometer HORUS at the University of Cologne. Proton beams with energies between 3.5 MeV and 5.0 MeV were provided by the 10 MV FN-Tandem accelerator leading to the determination of four new total cross-section values. After slight adjustments of the nuclear level density and γ-ray strength function an excellent agreement between theoretical calculations and experimentally deduced values for both total and partial cross sections has been obtained.

  6. Standardized uptake value of FDG corrected by lean body mass measured by DEXA

    International Nuclear Information System (INIS)

    Guirao, M.A.; Sanchez, A.M.; Saravi, F.D.; Mosconi, S.; Frias, L.

    2002-01-01

    Evaluating the metabolic activity of tumor lesion sometimes becomes important to evaluate grading of malignancy, prognosis, or response to therapy. The most used measure of the metabolic activity of [18F]-Fluorodeoxiglucose (FDG) in clinical PET is the Standardized Uptake Value (SUV). It relates the activity measured by the PET scan to the injected dose of FDG divided by the body mass. This approach overestimates SUV in 'heavy' patients, as the proportion of the 'low avid of FDG' fat mass increases. For this reason, different approaches are being evaluated to obtain a more accurate SUV measure. Aims: to compare the measured lean body mass by Dual X-Ray Absorptiometry with the previous methods of correction, to assess the more independent to the body constitution. Material and Methods: FDG metabolism was studied to 15 patients of both sexes, age between 28 and 72 y.o., body weight 55 to 92 Kg. One hour after the IV injection of 0.0045mCi/Kg of FDG, a whole body emission and transmission scan was performed to each subject in a positron emission tomograph (QUEST 250, GE-UGM, USA) for over 1 hour. Body lean mass composition was measured the same or next day by DEXA (Lunar DPX-L, USA.) ROIs were drawn on brain, liver and muscle. SUVbw =[(corrected mCi/g of tissue) / (mCi injected / body weight in grams)] was calculated for each tissue, and then recalculated replacing body weight with the measured lean body mass (SUVlm), calculated lean mass (SUVlc), body mass index (SUVmi) and body surface area (SUVsa). Corrected SUVs were normalized to each SUVbw average for a comparable visualization of results. Results: obtained data was analyzed by linear regression and curve estimation for each case in all tissues with the SPSS statistical software. A positive correlation between SUVbw and subject weight was confirmed for the 3 tissues. In Muscle and liver there was no significant correlation. The liver scanning time was variable ( 90 to 123 minutes after injection). Relating liver

  7. Influence of body position, food and beverage consumption on BIS measurements

    Science.gov (United States)

    Medrano, G.; Eitner, F.; Ismail, A. H.; Pikkemaat, R.; Cordes, A.; Floege, J.; Leonhardt, S.

    2010-04-01

    Continuous monitoring of fluid changes using bioimpedance spectroscopy (BIS) during hemodialysis could help to predict hypotensive complications and extend the patient's life. Food and beverage consumption during the treatment may influence the measurements and the calculated fluid removal. In the present article the change observed in whole body and segmental (knee-to-knee, abdomen) BIS measurements following a sequence similar to the one of dialysis treatment (lying down, sitting and eating, lying down) on healthy subjects is presented. The measurements have been performed using a commercial bioimpedance device with a frequency range of 5 kHz to 1 MHz. Knee-to-knee measurements seem to be less sensitive to these influences, compared to the standard whole body and the alternative abdomen BIS measurements. The results indicate that the individual influence of both body posture and food and beverage consumption may be superposed when combined.

  8. Partial-Body Irradiation in Patients with Prostate Cancer Treated with IMRT Has Little Effect on the Composition of Serum Proteome.

    Science.gov (United States)

    Pietrowska, Monika; Jelonek, Karol; Polanska, Joanna; Wojakowska, Anna; Marczak, Lukasz; Chawinska, Ewa; Chmura, Aleksanda; Majewski, Wojciech; Miszczyk, Leszek; Widlak, Piotr

    2015-06-30

    Partial body irradiation during cancer radiotherapy (RT) induces a response of irradiated tissues that could be observed at the level of serum proteome. Here we aimed to characterize the response to RT in group of patients treated because of prostate cancer. Five consecutive blood samples were collected before, during, and after the end of RT in a group of 126 patients who received definitive treatment with a maximum dose of 76 Gy. Serum peptidome, which was profiled in the 2000-16,000 Da range using MALDI-MS. Serum proteins were identified and quantified using the shotgun LC-MS/MS approach. The majority of changes in serum peptidome were detected between pre-treatment samples and samples collected after 3-4 weeks of RT (~25% of registered peptides changed their abundances significantly), yet the intensity of observed changes was not correlated significantly with the degree of acute radiation toxicity or the volume of irradiated tissues. Furthermore, there were a few serum proteins identified, the abundances of which were different in pre-RT and post-RT samples, including immunity and inflammation-related factors. Observed effects were apparently weaker than in comparable groups of head and neck cancer patients in spite of similar radiation doses and volumes of irradiated tissues in both groups. We concluded that changes observed at the level of serum proteome were low for this cohort of prostate cancer patients, although the specific components involved are associated with immunity and inflammation, and reflect the characteristic acute response of the human body to radiation.

  9. Partial-Body Irradiation in Patients with Prostate Cancer Treated with IMRT Has Little Effect on the Composition of Serum Proteome

    Directory of Open Access Journals (Sweden)

    Monika Pietrowska

    2015-06-01

    Full Text Available Partial body irradiation during cancer radiotherapy (RT induces a response of irradiated tissues that could be observed at the level of serum proteome. Here we aimed to characterize the response to RT in group of patients treated because of prostate cancer. Five consecutive blood samples were collected before, during, and after the end of RT in a group of 126 patients who received definitive treatment with a maximum dose of 76 Gy. Serum peptidome, which was profiled in the 2000–16,000 Da range using MALDI-MS. Serum proteins were identified and quantified using the shotgun LC-MS/MS approach. The majority of changes in serum peptidome were detected between pre-treatment samples and samples collected after 3–4 weeks of RT (~25% of registered peptides changed their abundances significantly, yet the intensity of observed changes was not correlated significantly with the degree of acute radiation toxicity or the volume of irradiated tissues. Furthermore, there were a few serum proteins identified, the abundances of which were different in pre-RT and post-RT samples, including immunity and inflammation-related factors. Observed effects were apparently weaker than in comparable groups of head and neck cancer patients in spite of similar radiation doses and volumes of irradiated tissues in both groups. We concluded that changes observed at the level of serum proteome were low for this cohort of prostate cancer patients, although the specific components involved are associated with immunity and inflammation, and reflect the characteristic acute response of the human body to radiation.

  10. Relationship between Arm Span Measurements and Body Height in Dinaric Alpes Population: a Systematic Review

    Directory of Open Access Journals (Sweden)

    Bojan Masanovic

    2017-08-01

    Full Text Available Several researches have reported the benefit of using various body parameters in predicting standing height, and arm span happened to be one of the most reliable ones in adults. On the other hand, it is well-known the tallness and body proportions are specific in the area that are covered by Dinaric Alpes. Therefore, the purpose of this study was to investigate the potential relationship between arm span measurements and body height in Dinaric Alpes population. The most visible electronic database (Google Scholar was searched for original research articles available until September 2017. Then research findings were summarized and relationship between arm span measurements and body height in Dinaric Alpes population were identified, as well as areas of future research were recommended. The assessment of body height using various anthropometric measures is very typical from the past centuries and it has been attempted to be studied by many researchers. However, it is important to underline that the arm span has been obtained as the most reliable body indicator for predicting the true height of an individual. However, the studies sampled with the populations lived at Dinaric Alpes mountains have specific estimates. Therefore, all above-mentioned have confirmed the necessity for developing separate body height models for each population on account of ethnic as well as regional differences.

  11. Reproducibility of DXA measurements of bone mineral density and body composition in children

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, Cheryl M.; Roza, Melissa A.; Webber, Colin E. [Hamilton Health Sciences, Department of Nuclear Medicine, Hamilton, ON (Canada); Barr, Ronald D. [McMaster Children' s Hospital, Hamilton, ON (Canada)

    2009-02-15

    The technique of X-ray-based dual photon absorptiometry (DXA) is frequently used in children for the detection of changes in bone mass or body composition. Such changes can only be considered real if the uncertainties arising from the measurement technique are exceeded. Our objectives were twofold: (1) to determine the reproducibility of bone mineral density (BMD) measurements in children at the spine and the hip and from the whole body, as well as of whole-body measurements of mineral mass, lean body mass and fat mass in children; and (2) to estimate, from the measured precision, the time interval that needs to elapse before a statistically significant change in a DXA variable can be detected. The reproducibility of techniques for the measurement of BMD and body composition using DXA was measured in 15 young children (9 girls and 6 boys) and 17 older children (9 girls and 8 boys). Reproducibility was derived from the standard deviation of three repeated measurements of spine BMD, total hip BMD, whole-body BMD (WBBMD), whole-body bone mineral content (WBBMC), lean mass and fat mass. Technique precision was better than 0.01 g cm{sup -2} for spine BMD and for WBBMD. Hip BMD measurements were slightly less precise, particularly in younger children (0.013 g cm{sup -2}). For body composition variables, technique precision was 13 g for WBBMC, 201 g for lean body mass and 172 g for fat mass in younger children. Technique precision for older children was 18 g, 251 g and 189 g for the corresponding variables. Predictions showed that the absence of a normal increase in WBBMC in a small-for-age girl could be established after 12 months. For spine BMD, a significant increase should be observable after 6 months for boys over the age of 11 years. For younger boys, more than 12 months has to elapse before anticipated changes can be detected with confidence. The time intervals required to elapse before decisions can be made concerning the significance of observed differences

  12. Reproducibility of DXA measurements of bone mineral density and body composition in children

    International Nuclear Information System (INIS)

    Leonard, Cheryl M.; Roza, Melissa A.; Webber, Colin E.; Barr, Ronald D.

    2009-01-01

    The technique of X-ray-based dual photon absorptiometry (DXA) is frequently used in children for the detection of changes in bone mass or body composition. Such changes can only be considered real if the uncertainties arising from the measurement technique are exceeded. Our objectives were twofold: (1) to determine the reproducibility of bone mineral density (BMD) measurements in children at the spine and the hip and from the whole body, as well as of whole-body measurements of mineral mass, lean body mass and fat mass in children; and (2) to estimate, from the measured precision, the time interval that needs to elapse before a statistically significant change in a DXA variable can be detected. The reproducibility of techniques for the measurement of BMD and body composition using DXA was measured in 15 young children (9 girls and 6 boys) and 17 older children (9 girls and 8 boys). Reproducibility was derived from the standard deviation of three repeated measurements of spine BMD, total hip BMD, whole-body BMD (WBBMD), whole-body bone mineral content (WBBMC), lean mass and fat mass. Technique precision was better than 0.01 g cm -2 for spine BMD and for WBBMD. Hip BMD measurements were slightly less precise, particularly in younger children (0.013 g cm -2 ). For body composition variables, technique precision was 13 g for WBBMC, 201 g for lean body mass and 172 g for fat mass in younger children. Technique precision for older children was 18 g, 251 g and 189 g for the corresponding variables. Predictions showed that the absence of a normal increase in WBBMC in a small-for-age girl could be established after 12 months. For spine BMD, a significant increase should be observable after 6 months for boys over the age of 11 years. For younger boys, more than 12 months has to elapse before anticipated changes can be detected with confidence. The time intervals required to elapse before decisions can be made concerning the significance of observed differences between

  13. Body measurements and carcass characteristics correlation of Nellore young bulls finishidedED IN FEEDLOT

    Directory of Open Access Journals (Sweden)

    Bruna Laurindo Rosa

    2014-10-01

    Full Text Available In this work it was aimed to evaluate Pearson correlations between body measurements, carcass characteristics and production of 35 Nellore bulls, confined for 96 days, with 402±14.90 kg and 18 months old. Weightings, ultrasound images and 14 measurements were obtained at the beginning of each experimental period and before slaughter, totaling four weight ratings of ultrasound images and measurements per animal. For the evaluation of body measurements and ultrasound images with carcass traits the values from the last measurement were considered. The images were made along with weighing animals through a Scanner, and measurements with a tape measure and a zoométrica cane, and these were correlated with each other and with productive and carcass characteristics. For measures of loin eye area evaluated by ultrasonography, it were found positive correlations with body length (0.32, rump (0.36 and thigh (0.20; withers height (0.20 and pelviano contour (0.38 (P<0.05. Variables of hip height and chest, chest width and pin bones, and heart girth showed positive correlations with two or more productive traits of economic interest, such as slaughter weight, hot carcass weight and dressing percentage (P<0.05. Significant correlations were found for most of the variables studied. Linear body measurements such as length and height emerge as a tool that can be useful in the formation of more homogenous lots and to predict the point of slaughter, along with the weight of the animals.

  14. Influence of visual and auditory biofeedback on partial body weight support treadmill training of individuals with chronic hemiparesis: a randomized controlled clinical trial.

    Science.gov (United States)

    Brasileiro, A; Gama, G; Trigueiro, L; Ribeiro, T; Silva, E; Galvão, É; Lindquist, A

    2015-02-01

    Stroke is an important causal factor of deficiency and functional dependence worldwide. To determine the immediate effects of visual and auditory biofeedback, combined with partial body weight supported (PBWS) treadmill training on the gait of individuals with chronic hemiparesis. Randomized controlled trial. Outpatient rehabilitation hospital. Thirty subjects with chronic hemiparesis and ability to walk with some help. Participants were randomized to a control group that underwent only PBWS treadmill training; or experimental I group with visual biofeedback from the display monitor, in the form of symbolic feet as the subject took a step; or experimental group II with auditory biofeedback associated display, using a metronome at 115% of the individual's preferred cadence. They trained for 20 minutes and were evaluated before and after training. Spatio-temporal and angular gait variables were obtained by kinematics from the Qualisys Motion Analysis system. Increases in speed and stride length were observed for all groups over time (speed: F=25.63; Phemiparesis, in short term. Additional studies are needed to determine whether, in long term, the biofeedback will promote additional benefit to the PBWS treadmill training. The findings of this study indicate that visual and auditory biofeedback does not bring immediate benefits on PBWS treadmill training of individuals with chronic hemiparesis. This suggest that, for additional benefits are achieved with biofeedback, effects should be investigated after long-term training, which may determine if some kind of biofeedback is superior to another to improve the hemiparetic gait.

  15. Impact of eating and drinking on body composition measurements by bioelectrical impedance.

    Science.gov (United States)

    Androutsos, O; Gerasimidis, K; Karanikolou, A; Reilly, J J; Edwards, C A

    2015-04-01

    Bioelectrical impedance analysis would be a more practical tool to measure body composition in clinical settings, dietetic practice and epidemiological studies if patients/subjects did not have to fast before measurements. The present study assessed whether the ingestion of food or drink had any biologically significant effect on bioimpedance measurements and body composition by the foot-to-foot method. Fifty-five healthy adults [30 males and 25 females; mean (SD) age 27.7 (7.1) years; mean (SD)body mass index 24 (3.8) kg m(-2)] were randomly assigned to a 2-day food trial (high-fat meal or high-carbohydrate meal) or a 2-day drink trial (water or high electrolyte drink). Body composition measurements were carried out in the fasting state, immediately after meal consumption and every 30 min for 2 h by the foot-to-foot single frequency bioimpedance technique. Bioimpedance increased significantly after the ingestion of food and fluid, although the changes were small. The electrolyte drink, high-fat and high-carbohydrate meals significantly increased the percentage body fat and fat mass. In all cases, the median percentage changes from baseline were approximately 1% in body fat percentage units. Although there were statistically significant changes in body composition estimates after food or drink consumption, these were small and within the imprecision of the impedance technique, and so are unlikely to be of clinical significance. The present study suggests that impedance measures of body fatness in clinical settings do not require strict adherence to fasting, and this should increase the opportunities for clinical application. © 2014 The British Dietetic Association Ltd.

  16. Use of a pulsed neutron generator for in vivo measurement of body carbon

    International Nuclear Information System (INIS)

    Kehayias, J.J.; Ellis, K.J.; Cohn, S.H.; Yasumura, S.

    1986-01-01

    The measurement of total body fat is of importance in studies of nutritional assessment, dietary regimens, and for the management of obesity. In the past, fat has been determined either by anthropometric methods, which introduce high uncertainties, or by model-dependent estimation of fat-free tissue. The validity, however, of the different models in disease is questionable. Total body carbon measurements provide a more direct evaluation of body fat both in normal subjects and in patients. The authors present here a facility for carbon measurements without the use of a major accelerator. The same facility can be used for the measurement of other major body elements and for the evaluation of the body's compartments. Carbon is measured in vivo through neutron inelastic scattering, by detecting the 4.44 MeV gamma rays. A miniature (10 cm long) 14 MeV D-T neutron generator is used. The short half-life of the 4.44 MeV state of carbon requires detection of the gamma rays simultaneously with the 10 μs neutron pulse. Generators with low pulsing rate were found inappropriate for carbon measurement because of their low duty-cycle (high neutron output during pulse). The detection system consists of NaI(T1) detectors and fast electronics for handling the high even rate during the neutron pulse. A description of the facility and an evaluation of the technique will be presented

  17. Multi frequency phase fluorimetry (MFPF) for oxygen partial pressure measurement: ex vivo validation by polarographic clark-type electrode.

    Science.gov (United States)

    Boehme, Stefan; Duenges, Bastian; Klein, Klaus U; Hartwich, Volker; Mayr, Beate; Consiglio, Jolanda; Baumgardner, James E; Markstaller, Klaus; Basciani, Reto; Vogt, Andreas

    2013-01-01

    Measurement of partial pressure of oxygen (PO2) at high temporal resolution remains a technological challenge. This study introduces a novel PO2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) PO2 measurements. MFPF technology was first investigated in N = 8 anaesthetised pigs at FIO2 of 0.21, 0.4, 0.6, 0.8 and 1.0. At each FIO2 level, blood samples were withdrawn and PO2 was measured in vitro with MFPF using two FOXY-AL300 probes immediately followed by CTE measurement. Secondly, MFPF-PO2 readings were compared to CTE in an artificial circulatory setup (human packed red blood cells, haematocrit of 30%). The impacts of temperature (20, 30, 40°C) and blood flow (0.8, 1.6, 2.4, 3.2, 4.0 L min(-1)) on MFPF-PO2 measurements were assessed. MFPF response time in the gas- and blood-phase was determined. Porcine MFPF-PO2 ranged from 63 to 749 mmHg; the corresponding CTE samples from 43 to 712 mmHg. Linear regression: CTE = 15.59+1.18*MFPF (R(2) = 0.93; P0.05). MFPF response-time (monoexponential) was 1.48±0.26 s for the gas-phase and 1.51±0.20 s for the blood-phase. MFPF-derived PO2 readings were reproducible and showed excellent correlation and good agreement with Clark-type electrode-based PO2 measurements. There was no relevant impact of temperature and blood flow upon MFPF-PO2 measurements. The response time of the MFPF FOXY-AL300 probe was adequate for real-time sensing in the blood phase.

  18. Neutron activation probe for measuring the presence of uranium in ore bodies

    International Nuclear Information System (INIS)

    Goldstein, N.P.; Smith, R.C.

    1979-01-01

    A neutron activation proble comprises a pulsed neutron source in series with a plurality of delayed neutron detectors for measuring radioactivity in a well borehole together with a NaI (Tl) counter for measuring the high energy 2.62 MeV gamma line from thorium. The neutron source emits neutrons which produce fission in uranium and thorium in the ore body and the delayed neutron detectors measure the delayed neutrons produced from such fission while the NaI (Tl) counter measures the 2.62 MeV gamma line from the undisturbed thorium in the ore body. The signal from the NaI (Tl) counter is processed and subtracted from the signal from the delayed neutron detectors with the result being indicative of the amount of uranium present in the ore body

  19. Quantitation of the degree of osteoporosis by measure of total-body calcium employing neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Zanzi, I.; Vaswani, A.; Wallach, S.; Aloia, J.; Ellis, K.J.

    1975-01-01

    Two techniques for measuring the amount of Ca in the total skeleton were employed: total-body neutron activation analysis (TBNAA) and the determination of the mineral content of a bone of the appendicular skeleton (absorptiometric measurement of the radius, BMC). (U.S.)

  20. Prediction of human core body temperature using non-invasive measurement methods.

    Science.gov (United States)

    Niedermann, Reto; Wyss, Eva; Annaheim, Simon; Psikuta, Agnes; Davey, Sarah; Rossi, René Michel

    2014-01-01

    The measurement of core body temperature is an efficient method for monitoring heat stress amongst workers in hot conditions. However, invasive measurement of core body temperature (e.g. rectal, intestinal, oesophageal temperature) is impractical for such applications. Therefore, the aim of this study was to define relevant non-invasive measures to predict core body temperature under various conditions. We conducted two human subject studies with different experimental protocols, different environmental temperatures (10 °C, 30 °C) and different subjects. In both studies the same non-invasive measurement methods (skin temperature, skin heat flux, heart rate) were applied. A principle component analysis was conducted to extract independent factors, which were then used in a linear regression model. We identified six parameters (three skin temperatures, two skin heat fluxes and heart rate), which were included for the calculation of two factors. The predictive value of these factors for core body temperature was evaluated by a multiple regression analysis. The calculated root mean square deviation (rmsd) was in the range from 0.28 °C to 0.34 °C for all environmental conditions. These errors are similar to previous models using non-invasive measures to predict core body temperature. The results from this study illustrate that multiple physiological parameters (e.g. skin temperature and skin heat fluxes) are needed to predict core body temperature. In addition, the physiological measurements chosen in this study and the algorithm defined in this work are potentially applicable as real-time core body temperature monitoring to assess health risk in broad range of working conditions.

  1. Q{sub {gamma}-H2AX}, an analysis method for partial-body radiation exposure using {gamma}-H2AX in non-human primate lymphocytes

    Energy Technology Data Exchange (ETDEWEB)

    Redon, Christophe E., E-mail: redonc@mail.nih.gov [NIH, NCI, CCR, Laboratory of Molecular Pharmacology, Bethesda, MD 20892 (United States); Nakamura, Asako J.; Gouliaeva, Ksenia [NIH, NCI, CCR, Laboratory of Molecular Pharmacology, Bethesda, MD 20892 (United States); Rahman, Arifur; Blakely, William F. [Armed Forces Radiobiology Research Institute, Uniformed Services University, Bethesda, MD 20889-5603 (United States); Bonner, William M. [NIH, NCI, CCR, Laboratory of Molecular Pharmacology, Bethesda, MD 20892 (United States)

    2011-09-15

    We previously used the {gamma}-H2AX assay as a biodosimeter for total-body irradiation (TBI) exposure ({gamma}-rays) in a rhesus macaque (Macaca mulatta) model. Utilizing peripheral blood lymphocytes and plucked hairs, we obtained statistically significant {gamma}-H2AX responses days after total-body exposure to 1-8.5 Gy ({sup 60}Co {gamma}-rays at 55 cGy min{sup -1}). Here, we introduce a partial-body exposure analysis method, Q{sub {gamma}-H2AX}, which is based on the number of {gamma}-H2AX foci per damaged cells as evident by having one or more {gamma}-H2AX foci per cell. Results from the rhesus monkey - TBI study were used to establish Q{sub {gamma}-H2AX} dose-response calibration curves to assess acute partial-body exposures. {gamma}-H2AX foci were detected in plucked hairs for several days after in vivo irradiation demonstrating this assay's utility for dose assessment in various body regions. The quantitation of {gamma}-H2AX may provide a robust biodosimeter for analyzing partial-body exposures to ionizing radiation in humans.

  2. Methods of Assessing Body Fatness among Children: Implications for the National Child Measurement Programme

    Science.gov (United States)

    Wheeler, Sharon; Twist, Craig

    2010-01-01

    Body mass index (BMI) is increasingly recognized as an inadequate measure for determining obesity in children. Therefore, the aim within this study was to investigate other indirect methods of body fat assessment that could potentially be used in place of BMI. Twenty-four children (boys: 13.8 [plus or minus] 0.8 yr; girls: 13.3 [plus or minus] 0.5…

  3. Electric Field Measurement of the Living Human Body for Biomedical Applications: Phase Measurement of the Electric Field Intensity

    Directory of Open Access Journals (Sweden)

    Ichiro Hieda

    2013-01-01

    Full Text Available The authors are developing a technique for conducting measurements inside the human body by applying a weak electric field at a radio frequency (RF. Low RF power is fed to a small antenna, and a similar antenna located 15–50 cm away measures the electric field intensity. Although the resolution of the method is low, it is simple, safe, cost-effective, and able to be used for biomedical applications. One of the technical issues suggested by the authors' previous studies was that the signal pattern acquired from measurement of a human body was essentially different from that acquired from a phantom. To trace the causes of this difference, the accuracy of the phase measurements was improved. This paper describes the new experimental system that can measure the signal phase and amplitude and reports the results of experiments measuring a human body and a phantom. The results were analyzed and then discussed in terms of their contribution to the phase measurement.

  4. Calorimetry Minisensor for the Localised Measurement of Surface Heat Dissipated from the Human Body.

    Science.gov (United States)

    Socorro, Fabiola; Rodríguez de Rivera, Pedro Jesús; Rodríguez de Rivera, Manuel

    2016-11-06

    We have developed a calorimetry sensor that can perform a local measurement of the surface heat dissipated from the human body. The operating principle is based on the law of conductive heat transfer: heat dissipated by the human body passes across a thermopile located between the individual and a thermostat. Body heat power is calculated from the signals measured by the thermopile and the amount of power dissipated across the thermostat in order to maintain a constant temperature. The first prototype we built had a detection area measuring 6 × 6 cm², while the second prototype, which is described herein, had a 2 × 2 cm² detection area. This new design offers three advantages over the initial one: (1) greater resolution and three times greater thermal sensitivity; (2) a twice as fast response; and (3) it can take measurements from smaller areas of the body. The sensor has a 5 mW resolution, but the uncertainty is greater, up to 15 mW, due to the measurement and calculation procedure. The order of magnitude of measurements made in healthy subjects ranged from 60 to 300 mW at a thermostat temperature of 28 °C and an ambient room temperature of 21 °C. The values measured by the sensor depend on the ambient temperature and the thermostat's temperature, while the power dissipated depends on the individual's metabolism and any physical and/or emotional activity.

  5. Beyond Body Mass Index: Using Anthropometric Measures and Body Composition Indicators to Assess Odds of an Endometriosis Diagnosis.

    Science.gov (United States)

    Backonja, Uba; Hediger, Mary L; Chen, Zhen; Lauver, Diane R; Sun, Liping; Peterson, C Matthew; Buck Louis, Germaine M

    2017-09-01

    Body mass index (BMI) and endometriosis have been inversely associated. To address gaps in this research, we examined associations among body composition, endometriosis, and physical activity. Women from 14 clinical sites in the Salt Lake City, Utah and San Francisco, California areas and scheduled for laparoscopy/laparotomy were recruited during 2007-2009. Participants (N = 473) underwent standardized anthropometric assessments to estimate body composition before surgery. Using a cross-sectional design, odds of an endometriosis diagnosis (adjusted odds ratio [aOR]; 95% confidence interval [CI]) were calculated for anthropometric and body composition measures (weight in kg; height in cm; mid upper arm, waist, hip, and chest circumferences in cm; subscapular, suprailiac, and triceps skinfold thicknesses in mm; arm muscle and fat areas in cm 2 ; centripetal fat, chest-to-waist, chest-to-hip, waist-to-hip, and waist-to-height ratios; arm fat index; and BMI in kg/m 2 ). Physical activity (metabolic equivalent of task-minutes/week) and sedentariness (average minutes sitting on a weekday) were assessed using the International Physical Activity Questionnaire-Short Form. Measures were modeled continuously and in quartiles based on sample estimates. Adjusted models were controlled for age (years, continuous), site (Utah/California), smoking history (never, former, or current smoker), and income (below, within 180%, and above of the poverty line). Findings were standardized by dividing variables by their respective standard deviations. We used adjusted models to examine whether odds of an endometriosis diagnosis were moderated by physical activity or sedentariness. Inverse relationships were observed between endometriosis and standardized: weight (aOR = 0.71, 95% CI 0.57-0.88); subscapular skinfold thickness (aOR = 0.79, 95% CI 0.65-0.98); waist and hip circumferences (aOR = 0.79, 95% CI 0.64-0.98 and aOR = 0.76, 95% CI 0.61-0.94, respectively); total

  6. Carotid body size measured by computed tomographic angiography in individuals born prematurely.

    Science.gov (United States)

    Bates, Melissa L; Welch, Brian T; Randall, Jess T; Petersen-Jones, Humphrey G; Limberg, Jacqueline K

    2018-05-24

    We tested the hypothesis that the carotid bodies would be smaller in individuals born prematurely or exposed to perinatal oxygen therapy when compared individuals born full term that did not receive oxygen therapy. A retrospective chart review was conducted on patients who underwent head/neck computed tomography angiography (CTA) at the Mayo Clinic between 10 and 40 years of age (n = 2503). Patients were identified as premature ( body images captured during the CTA were performed. Carotid body visualization was possible in 43% of patients and 52% of age, sex, and body mass index (BMI)-matched controls but only 17% of juvenile preterm subjects (p = 0.07). Of the carotid bodies that could be visualized, widest axial measurements of the carotid bodies in individuals born prematurely (n = 7, 34 ± 4 weeks gestation, birth weight: 2460 ± 454 g; average size: 2.5 ± 0.2 cm) or individuals exposed to perinatal oxygen therapy (n = 3, 38 ± 2 weeks gestation, Average size: 2.2 ± 0.1 cm) were not different when compared to controls (2.3 ± 0.2 cm and 2.3 ± 0.2 cm, respectively, p > 0.05). Carotid body size, as measured using CTA, is not smaller in adults born prematurely or exposed to perinatal oxygen therapy when compared to sex, age, and BMI-matched controls. However, carotid body visualization was lower in juvenile premature patients. The decreased ability to visualize the carotid bodies in these individuals may be a result of their prematurity. Copyright © 2018. Published by Elsevier B.V.

  7. Comparison of Dolphins' Body and Brain Measurements with Four Other Groups of Cetaceans Reveals Great Diversity.

    Science.gov (United States)

    Ridgway, Sam H; Carlin, Kevin P; Van Alstyne, Kaitlin R; Hanson, Alicia C; Tarpley, Raymond J

    2016-01-01

    We compared mature dolphins with 4 other groupings of mature cetaceans. With a large data set, we found great brain diversity among 5 different taxonomic groupings. The dolphins in our data set ranged in body mass from about 40 to 6,750 kg and in brain mass from 0.4 to 9.3 kg. Dolphin body length ranged from 1.3 to 7.6 m. In our combined data set from the 4 other groups of cetaceans, body mass ranged from about 20 to 120,000 kg and brain mass from about 0.2 to 9.2 kg, while body length varied from 1.21 to 26.8 m. Not all cetaceans have large brains relative to their body size. A few dolphins near human body size have human-sized brains. On the other hand, the absolute brain mass of some other cetaceans is only one-sixth as large. We found that brain volume relative to body mass decreases from Delphinidae to a group of Phocoenidae and Monodontidae, to a group of other odontocetes, to Balaenopteroidea, and finally to Balaenidae. We also found the same general trend when we compared brain volume relative to body length, except that the Delphinidae and Phocoenidae-Monodontidae groups do not differ significantly. The Balaenidae have the smallest relative brain mass and the lowest cerebral cortex surface area. Brain parts also vary. Relative to body mass and to body length, dolphins also have the largest cerebellums. Cortex surface area is isometric with brain size when we exclude the Balaenidae. Our data show that the brains of Balaenidae are less convoluted than those of the other cetaceans measured. Large vascular networks inside the cranial vault may help to maintain brain temperature, and these nonbrain tissues increase in volume with body mass and with body length ranging from 8 to 65% of the endocranial volume. Because endocranial vascular networks and other adnexa, such as the tentorium cerebelli, vary so much in different species, brain size measures from endocasts of some extinct cetaceans may be overestimates. Our regression of body length on endocranial

  8. Characteristics of attention-related body sensations. Temporal stability and associations with measures of body focus, affect, sustained attention, and heart rate variability.

    Science.gov (United States)

    Tihanyi, Benedek T; Ferentzi, Eszter; Köteles, Ferenc

    2017-09-01

    This study investigated the temporal stability and correlates of attention-related body sensations that emerge without external stimulation during rest and due to focused attention on a body part. To assess attention-related body sensations, participants were asked to focus on a freely chosen body area with closed eyes, and had to report whether the sensation of that area had changed. Self-report questionnaires were used to assess various aspects of body focus (body awareness, body responsiveness, somatosensory amplification, subjective somatic symptoms), and positive and negative affectivity. Previous experiences in body-mind therapies were also measured. PEBL Continuous Performance Test was used to assess sustained attention. Heart rate variability scores were based on a 3-minute long resting heart rate measurement. Fifty-eight university students (22.3 ± 3.95 years; 34 females) participated in the study. The stability of attention-related body sensations was measured 8 weeks later on a randomly chosen sub-group (n = 28). Attention-related body sensations showed a mediocre temporal stability (r ρ  = 0.47, p = 0.012). People reporting attention-related body sensations showed significantly higher body awareness, somatosensory amplification, and resting heart rate; and marginally higher somatic symptoms. No relation was found with body-mind practice, body responsiveness, positive and negative affect, the vagal component of heart rate variability, and performance in the sustained attention task. Attention-related sensations are relatively stable over time. They are connected to some, but not to all of the aspects of body focus. Further studies are needed to elaborate the influencing stable and situational factors.

  9. Hepatic contrast medium enhancement at computed tomography and its correlation with various body size measures

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Nouhad, Jallo; Cederlund, Kerstin; Aspelin, Peter; Torkel, Brismar B., E-mail: anders.svensson@karolinska.se [Dept. of Clinical Science, Intervention and Technology at Karolinska Inst., Div. of Medical Imaging and Technology, Stockholm (Sweden); (Dept. of Radiology, Karolinska Univ. Hospital, Huddinge, Stockholm (Sweden)); Nyman, Ulf (Dept. of Diagnostic Radiology, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden)); Bjoerk, Jonas (Competence Centre for Clinical Research, Skaane Univ. Hospital, Lund (Sweden)

    2012-07-15

    Background. When the same dose of iodine is given to all patients when performing abdominal computed tomography (CT) there may be a wide inter-individual variation in contrast medium (CM) enhancement of the liver. Purpose. To evaluate if any of the measures body height (BH), body mass index (BMI), lean body mass (LBM), ideal body weight (IBW), and body surface area (BSA) correlated better than body weight (BW) with hepatic enhancement, and to compare the enhancement when using iodixanol and iomeprol. Material and Methods. One hundred patients referred for standard three-phase CT examination of abdomen were enrolled. Body weight and height were measured at the time of the CT examination. Forty grams of iodine (iodixanol 320 mg I/mL or iomeprol 400 mg I/mL) was injected at a rate of 1.6 g-I/s, followed by a 50 mL saline flush. The late arterial phase was determined by using a semi-automatic smart prep technique with a scan delay of 20 s. The hepatic parenchymal phase started automatically 25 s after the late arterial phase. CM concentration was estimated by placement of regions of interest in aorta (native and late arterial phase) and in liver (native and parenchymal phase). Results. BW (r -0.51 and -0.64), LBM (r = -0.54 and -0.59), and BSA (r -0.54 and -0.65) showed the best correlation coefficients with aortic and hepatic parenchymal enhancement, respectively, without any significant differences between the measures. Comparing iodixanol and iomeprol there was no significant difference in aortic enhancement. The liver enhancement was significantly higher (P < 0.05) using iodixanol than iomeprol. Conclusion. To achieve a consistent hepatic enhancement, CM dose may simply be adjusted to body weight instead of using more complicated calculated parameters based on both weight and height.

  10. Wearable sensors in intelligent clothing for measuring human body temperature based on optical fiber Bragg grating.

    Science.gov (United States)

    Li, Hongqiang; Yang, Haijing; Li, Enbang; Liu, Zhihui; Wei, Kejia

    2012-05-21

    Measuring body temperature is considerably important to physiological studies as well as clinical investigations. In recent years, numerous observations have been reported and various methods of measurement have been employed. The present paper introduces a novel wearable sensor in intelligent clothing for human body temperature measurement. The objective is the integration of optical fiber Bragg grating (FBG)-based sensors into functional textiles to extend the capabilities of wearable solutions for body temperature monitoring. In addition, the temperature sensitivity is 150 pm/°C, which is almost 15 times higher than that of a bare FBG. This study combines large and small pipes during fabrication to implant FBG sensors into the fabric. The law of energy conservation of the human body is considered in determining heat transfer between the body and its clothing. The mathematical model of heat transmission between the body and clothed FBG sensors is studied, and the steady-state thermal analysis is presented. The simulation results show the capability of the material to correct the actual body temperature. Based on the skin temperature obtained by the weighted average method, this paper presents the five points weighted coefficients model using both sides of the chest, armpits, and the upper back for the intelligent clothing. The weighted coefficients of 0.0826 for the left chest, 0.3706 for the left armpit, 0.3706 for the right armpit, 0.0936 for the upper back, and 0.0826 for the right chest were obtained using Cramer's Rule. Using the weighting coefficient, the deviation of the experimental result was ± 0.18 °C, which favors the use for clinical armpit temperature monitoring. Moreover, in special cases when several FBG sensors are broken, the weighted coefficients of the other sensors could be changed to obtain accurate body temperature.

  11. Measurement of whole-body human centers of gravity and moments of inertia.

    Science.gov (United States)

    Albery, C B; Schultz, R B; Bjorn, V S

    1998-06-01

    With the inclusion of women in combat aircraft, the question of safe ejection seat operation has been raised. The potential expanded population of combat pilots would include both smaller and larger ejection seat occupants, which could significantly affect seat performance. The method developed to measure human whole-body CG and MOI used a scale, a knife edge balance, and an inverted torsional pendulum. Subjects' moments of inertia were measured along six different axes. The inertia tensor was calculated from these values, and principal moments of inertia were then derived. Thirty-eight antropometric measurements were also taken for each subject to provide a means for direct correlation of inertial properties to body dimensions and for modeling purposes. Data collected in this study has been used to validate whole-body mass properties predictions. In addition, data will be used to improve Air Force and Navy ejection seat trajectory models for the expanded population.

  12. In vivo ultrasound and biometric measurements predict the empty body chemical composition in Nellore cattle.

    Science.gov (United States)

    Castilhos, A M; Francisco, C L; Branco, R H; Bonilha, S F M; Mercadante, M E Z; Meirelles, P R L; Pariz, C M; Jorge, A M

    2018-05-04

    Evaluation of the body chemical composition of beef cattle can only be measured postmortem and those data cannot be used in real production scenarios to adjust nutritional plans. The objective of this study was to develop multiple linear regression equations from in vivo measurements, such as ultrasound parameters [backfat thickness (uBFT, mm), rump fat thickness (uRF, mm), and ribeye area (uLMA, cm2)], shrunk body weight (SBW, kg), age (AG, d), hip height (HH, m), as well as from postmortem measurements (composition of the 9th to 11th rib section) to predict the empty body and carcass chemical composition for Nellore cattle. Thirty-three young bulls were used (339 ± 36.15 kg and 448 ± 17.78 d for initial weight and age, respectively). Empty body chemical composition (protein, fat, water, and ash in kg) was obtained by combining noncarcass and carcass components. Data were analyzed using the PROC REG procedure of SAS software. Mallows' Cp values were close to the ideal value of number of independent variables in the prediction equations plus one. Equations to predict chemical components of both empty body and carcass using in vivo measurements presented higher R2 values than those determined by postmortem measurements. Chemical composition of the empty body using in vivo measurements was predicted with R2 > 0.73. Equations to predict chemical composition of the carcass from in vivo measurements showed R2 lower (R2Chemical compounds from components of the empty body of Nellore cattle can be calculated by the following equations: protein (kg) = 47.92 + 0.18 × SBW - 1.46 × uRF - 30.72 × HH (R2 = 0.94, RMSPE = 1.79); fat (kg) = 11.33 + 0.16 × SBW + 2.09 × uRF - 0.06 × AG (R2 = 0.74, RMSPE = 4.18); water (kg) = - 34.00 + 0.55 × SBW + 0.10 × AG - 2.34 × uRF (R2 = 0.96, RMSPE = 5.47). In conclusion, the coefficients of determination (for determining the chemical composition of the empty body) of the equations derived from in vivo measures were higher than those

  13. Evaluation of body condition score measured throughout lactation as an indicator of fertility in dairy cattle

    OpenAIRE

    Banos, G; Brotherstone, S; Coffey, MP

    2004-01-01

    Body condition score (BCS) records of primiparous Holstein cows were analyzed both as a single measure per animal and as repeated measures per sire of cow. The former resulted in a single, average, genetic evaluation for each sire, and the latter resulted in separate genetic evaluations per day of lactation. Repeated measure analysis yielded genetic correlations of less than unity between days of lactation, suggesting that BCS may not be the same trait across lactation. Differences between da...

  14. A study on the applicability of implantable microchip transponders for body temperature measurements in pigs

    Directory of Open Access Journals (Sweden)

    Enøe Claes

    2010-05-01

    Full Text Available Abstract Background The applicability of an electronic monitoring system using microchip transponders for measurement of body temperatures was tested in 6-week-old conventional Danish weaners infected with classical swine fever virus (CSFV. Subcutaneous tissue temperatures obtained by the implantable transponders were compared with rectal temperatures, recorded by a conventional digital thermometer. Methods In a preliminary study, transponders were inserted subcutaneously at 6 different positions of the body of 5 pigs. The transponders positioned by the ear base provided the best correlation to rectal temperature. To test the stability of the monitoring system in a larger group of pigs, transponders were therefore inserted by the left ear base in a subsequent infection experiment with 30 pigs. Results Generally, the microchip transponders measured a subcutaneous tissue temperature, which was about 1°C lower than the rectal temperature. However, a simple linear relationship between the measures of the two methods was found. Conclusions Our study showed that the tested body monitoring system may represent a promising tool to obtain an approximate correlate of body temperatures in groups of pigs. In contrast, however, the tested system did not constitute a suitable tool to measure body temperatures of individual animals in the present pig infection experiment.

  15. Measurement of total-body cobalt-57 vitamin B12 absorption with a gamma camera

    International Nuclear Information System (INIS)

    Cardarelli, J.A.; Slingerland, D.W.; Burrows, B.A.; Miller, A.

    1985-01-01

    Previously described techniques for the measurement of the absorption of [ 57 Co]vitamin B 12 by total-body counting have required an iron room equipped with scanning or multiple detectors. The present study uses simplifying modifications which make the technique more available and include the use of static geometry, the measurement of body thickness to correct for attenuation, a simple formula to convert the capsule-in-air count to a 100% absorption count, and finally the use of an adequately shielded gamma camera obviating the need of an iron room

  16. Measurement of total body chlorine by prompt gamma in vivo neutron activation analysis

    International Nuclear Information System (INIS)

    Beddoe, A.H.; Streat, S.J.; Hill, G.L.

    1987-01-01

    A method of measuring total body chlorine (TBCl) by prompt gamma in vivo neutron activation analysis is described depending on the same NaI(Tl) spectra used for determinations of total body nitrogen. Ratios of chlorine to hydrogen are derived and TBCl determined using a model of body composition depending on measured body weight, total body water (by tritium dilution) and protein (6.25 x nitrogen) as well as estimated body minerals and glycogen. The precision of the method based on scanning an anthropomorphic phantom is approximately 9% (SD), for a patient dose equivalent of less than 0.30 mSv. Spectra collected from 67 normal volunteers (32 male, 35 female) yielded mean values of TBCl of 72 +- 19 (SD) g in males and 53.6 +- 15 g in females, in broad agreement with values reported by workers using delayed gamma methods. Results are presented for two human cadavers analysed by neutron activation and conventional chemical analysis; the ratios of TBCl (neutron activation) to TBCl (chemical) were 0.980 +- 0.028 (SEM) and 0.91 +- 0.09. It is suggested that an improvement in precision will be achieved by increasing the scanning time (thereby increasing the radiation dose equivalent) and by adding two more detectors. (author)

  17. Further development of drag bodies for the measurement of mass flow rates during blowdown experiments

    International Nuclear Information System (INIS)

    Brockmann, E.; John, H.; Reimann, J.

    1983-01-01

    Drag bodies have already been used for sometime for the measurement of mass flow rates in blowdown experiments. Former research concerning the drag body behaviour in non-homogeneous two-phase flows frequently dealt with special effects by means of theoretical models only. For pipe flows most investigations were conducted for ratios of drag plate area to pipe cross section smaller 0.02. The present paper gives the results of experiments with drag bodies in a horizontal, non-homogeneous two-phase pipe flow with slip, which were carried through under the sponsorship of the German Ministry for Research and Technology (BMFT). Special interest was layed on the behaviour of the drag coefficient in stationary flows and at various cross sectional ratios. Both design and response of various drag bodies, which were developed at the Battelle-Institut, were tested in stationary and instationary two-phase flows. The influences of density and velocity profiles as well as the drag body position were studied. The results demonstrate, that the drag body is capable of measuring mass flow rates in connection with a gamma densitometer also in non-homogeneous two-phase flows. Satisfying results could be obtained, using simply the drag coefficient which was determined from single-phase flow calibrations

  18. Spectral composition of a measuring signal during measurements of vibration rates of a moving body

    Science.gov (United States)

    Daynauskas, I. A. I.; Slepov, N. N.

    1973-01-01

    Cybernetics diagnostics of machines and mechanisms using the spectral approach is discussed. The problem of establishing the accuracy of determination of the spectral composition is investigated. In systems with rectilinear or rotary movement, the vibrations appear in the form of movement rate vibrations, which are equivalent to frequency modulation of the signal, in proportion to the mean movement rate of the body. The case of a harmonic signal which reproduces and analyzes the characteristics of the frequency modulated signal is discussed. Mathematical models are developed to show the relationships of the parameters.

  19. New possibilities in the prevention of eating disorders: The introduction of positive body image measures.

    Science.gov (United States)

    Piran, Niva

    2015-06-01

    Delineating positive psychological processes in inhabiting the body, as well as quantitative measures to assess them, can facilitate progress in the field of prevention of eating disorders by expanding outcome evaluation of prevention interventions, identifying novel mediators of change, and increasing highly needed research into protective factors. Moreover, enhancing positive ways of inhabiting the body may contribute toward the maintenance of gains of prevention interventions. Integrated social etiological models to eating disorders that focus on gender and other social variables, such as the Developmental Theory of Embodiment (Piran & Teall, 2012a), can contribute to positive body image intervention development and research within the prevention field. Using the Developmental Theory of Embodiment as a lens, this article explores whether existing prevention programs (i.e., Cognitive Dissonance and Media Smart) may already work to promote positive body image, and whether prevention programs need to be expanded toward this goal. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Simulating local measurements on a quantum many-body system with stochastic matrix product states

    DEFF Research Database (Denmark)

    Gammelmark, Søren; Mølmer, Klaus

    2010-01-01

    We demonstrate how to simulate both discrete and continuous stochastic evolutions of a quantum many-body system subject to measurements using matrix product states. A particular, but generally applicable, measurement model is analyzed and a simple representation in terms of matrix product operators...... is found. The technique is exemplified by numerical simulations of the antiferromagnetic Heisenberg spin-chain model subject to various instances of the measurement model. In particular, we focus on local measurements with small support and nonlocal measurements, which induce long-range correlations....

  1. Body Measurements of Donkeys of Poitevin and Catalan Breeds and their Crossbreds in Morocco

    Directory of Open Access Journals (Sweden)

    I. Boujenane

    2008-01-01

    Full Text Available The study concerned the analysis of body measurements of 125 Poitevin (P, 107 Catalan (C and 77 reciprocal crossbred (PxC et CxP donkeys used in the national stud farms of Morocco. The donkeys were born between 1937 and 1973 in Morocco, France and Spain. The genetic type had a significant effect on all measurements studied except on the height at withers. Poitevin donkeys had a height at withers, heart girth, body weight, body length, substernal gap and front cannon bone circumference of 139.7 cm, 152.4 cm, 346.4 kg, 143.2 cm, 76.8 cm and 20.5 cm, respectively. Compared to Catalan donkeys the differences were – 0.5 cm, 2.7 cm, 15.7 kg, 3.7 cm, – 1.4 cm and 1.5 cm, and compared to crossbreds 1.4 cm, 2.3 cm, 14.2 kg, 5.1 cm, – 0.5 cm and 1.3 cm, respectively. The heterosis effect was significant for the body length (– 2.30% and the front cannon bone circumference (– 2.78% only. It was concluded that body measurements of Poitevin and Catalan donkey breeds were slightly different.

  2. Body measurements and testosteron level of male Timor deer (Rusa timorensis at various hierarchies

    Directory of Open Access Journals (Sweden)

    D. Samsudewa

    2017-12-01

    Full Text Available The aim of this research was to observe body (neck, chest and scrotum circumferences and testosterone level of α-male, β-male and subordinate male Timor deer reared under captivity after establisment of the dominance hierarchy. Twelve males (51 ± 6 months old; 68.29 ± 8.41 kg body weight and in same antler stages were used in this research. The bucks was grouped into three stall each containing four bucks. ELISA kit and tape measurements were used for plasma Testosterone assay and body measurement, respectively. Data was collected before and 43 days after establishment of the dominance hierarchy. Wilcoxon signed ranks test and Kruskal-Wallis H test of non-parametric analysis was used. Significant difference was tested with Mann-Whitney U test. The results showed no significantly different for body circumferences (neck, chest, scrotum and testosterone level of male Timor deer before establishment of dominance hierarchy. Chest and scrotum circumferences of male Timor deer after establihment of dominance hierarchy showed no significantly different. Significantly difference shown on parameter neck circumference (P<0.05; χ2 = 8.74 and testosteron level (P<0.05; χ2 = 7.87 after establishment of dominance hierarchy. In conclusion, dominance hierarchy affected the testosterone level and body measurement.

  3. Multi Frequency Phase Fluorimetry (MFPF) for Oxygen Partial Pressure Measurement: Ex Vivo Validation by Polarographic Clark-Type Electrode

    Science.gov (United States)

    Boehme, Stefan; Duenges, Bastian; Klein, Klaus U.; Hartwich, Volker; Mayr, Beate; Consiglio, Jolanda; Baumgardner, James E.; Markstaller, Klaus; Basciani, Reto; Vogt, Andreas

    2013-01-01

    Background Measurement of partial pressure of oxygen (PO2) at high temporal resolution remains a technological challenge. This study introduces a novel PO2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) PO2 measurements. Methodology/Principal Findings MFPF technology was first investigated in N = 8 anaesthetised pigs at FIO2 of 0.21, 0.4, 0.6, 0.8 and 1.0. At each FIO2 level, blood samples were withdrawn and PO2 was measured in vitro with MFPF using two FOXY-AL300 probes immediately followed by CTE measurement. Secondly, MFPF-PO2 readings were compared to CTE in an artificial circulatory setup (human packed red blood cells, haematocrit of 30%). The impacts of temperature (20, 30, 40°C) and blood flow (0.8, 1.6, 2.4, 3.2, 4.0 L min−1) on MFPF-PO2 measurements were assessed. MFPF response time in the gas- and blood-phase was determined. Porcine MFPF-PO2 ranged from 63 to 749 mmHg; the corresponding CTE samples from 43 to 712 mmHg. Linear regression: CTE = 15.59+1.18*MFPF (R2 = 0.93; PPO2 ranged from 20 to 567 mmHg and CTE samples from 11 to 575 mmHg. Linear regression: CTE = −8.73+1.05*MFPF (R2 = 0.99; PPO2 due to variations of temperature were less than 6 mmHg (range 0–140 mmHg) and less than 35 mmHg (range 140–750 mmHg); differences due to variations in blood flow were less than 15 mmHg (all P-values>0.05). MFPF response-time (monoexponential) was 1.48±0.26 s for the gas-phase and 1.51±0.20 s for the blood-phase. Conclusions/Significance MFPF-derived PO2 readings were reproducible and showed excellent correlation and good agreement with Clark-type electrode-based PO2 measurements. There was no relevant impact of temperature and blood flow upon MFPF-PO2 measurements. The response time of the MFPF FOXY-AL300 probe was adequate for real-time sensing in the blood phase. PMID:23565259

  4. Implant-supported mandibular removable partial dentures; patient-based outcome measures in relation to implant position.

    Science.gov (United States)

    Jensen, Charlotte; Raghoebar, Gerry M; Kerdijk, Wouter; Meijer, Henny J A; Cune, Marco S

    2016-12-01

    To assess the benefits of implant support to Removable Partial Dentures (RPD) in patients with a bilateral free-ending situation in the mandible and to determine the most favorable implant position: the premolar (PM) or the molar (M) region. Thirty subjects with a bilateral unbounded posterior saddle received 2 PM and 2M implants. A new RPD was placed. Implant support was provided 3 months later. Two PM implants supported the RPD. After 3 months the 2M implants were used or vice versa. Outcome measures included oral health related quality of life (OHIP-NL49), general health status (SF-36), contentment assessed on a Visual Analogue Scale (VAS) and the number of hours that the RPD was worn. Data were collected prior to treatment, 3 months after having functioned with a new RPD and after 3 and 6 months with implant support. Finally, patients expressed their preferred implant position. The general health status (SF-36) was not influenced. OHIP-NL49 values and mean wearing-time were statistical significantly more favorable for ISRPD's, regardless of the implant position. Per day, the ISRPD's were worn 2-3h more than the unsupported new RPD. Patients' expectations were met as the VAS-scores of anticipated and realized contentment did not reach a statistical significant level (p>0.05). VAS scores for ISRPD's with M implant support were higher than for PM implant support. Finally, 56.7% of subjects preferred the M implant support, 13.3% expressed no preference and 30% opted for PM implant support. Mandibular implant support favorably influences oral health related patient-based outcome measures in patients with a bilateral free-ending situation. The majority of patients prefer the implant support to be in the molar region. Patients with a bilateral free-ending situation in the mandible opposed by a maxillary denture benefit from implant support to their mandibular removable partial denture. Most patients prefer this support to be in the molar region. Copyright © 2016

  5. Changes in CT density-measurement of intraorbital wooden foreign bodies

    International Nuclear Information System (INIS)

    Otani, Etsuko; Hiyama, Fusako; Machi, Setsuko; Hagihara, Masahiro.

    1991-01-01

    We examined in vitro changes in CT density-measurement of intraorbital wooden foreign bodies. Dry wooden sticks were immersed in distilled water, saline, and serum. Computerized tomography scans were taken several times during 22 weeks. Scans were taken in room air and in fatty tissue. The CT density-measurement of the central part of the wooden bodies was calculated. That of the dry wood was about 500 HU; all of the wooden foreign bodies became denser during the 22 weeks, with those immersed in distilled water and saline at about 130 HU, and those immersed in serum at about 150 HU. It was confirmed that wood becomes denser after soaking in aqueous environments. The CT density of wood soaked in water depends on the density of wood fiber, and the CT density of the wood fiber itself. (author)

  6. A simple calibration of a whole-body counter for the measurement of total body potassium in humans

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; El-Fiki, S.A.; El-Enany, N.; Youssef, S.K.; Aly, A.M.; Abbas, M.T.

    1992-01-01

    A simple calibration procedure for the Inshas whole body counter for evaluating total body potassium has been adopted. More than 120 Egyptian employees in the Nuclear Research Center (N.R.C.) were studied for their total body potassium (TBK). The potassium values were found to have an average of 2.85±0.57 g K kg -1 body weight for males and 2.62±0.52 g K kg -1 for females, which are higher than the recommended value given for reference man by ICRP. The TBK varied directly with body build index and is slightly sex dependent (Author)

  7. Combine body mass index and body fat percentage measures to improve the accuracy of obesity screening in young adults.

    Science.gov (United States)

    Hung, Shang-Ping; Chen, Ching-Yu; Guo, Fei-Ran; Chang, Ching-I; Jan, Chyi-Feng

    Obesity screening among young adult groups is meaningful. Body mass index (BMI) is limited to discriminate between fat and lean mass. Asian young adult group tends to have lower BMI and higher body fat percentage (BFP) than other ethnic groups. Accuracy of obesity screening by commonly used BMI criteria is unclear in young Taiwanese population. A total of 894 young adults (447 males and 447 females) aged 20-26 were recruited. BMI, regional fat percentage and BFP determined by bioelectrical impedance analysis (BIA) were measured. BMI cutoff points were based on the criteria adopted by the Ministry of Health and Welfare in Taiwan. Cutoff points of low or high BFP were defined as 24% in men and 31.4% in women. Prevalence of BFP defining obesity was 14.8% in young men and 27.3% in young women. 23.2% of young men and only 8.3% of young women were classified to overweight or obesity categories according to the BMI criteria. Disagreement was noticed mainly among overweight males and normal weight females. 68.7% of BMI defining overweight young men had low BFP; however, 29.7% of young women of BMI defining normal group had high BFP. Up to 69.7% of young women with high BFP would be missed by BMI category only. Disagreement between BMI and BFP was significant among young adults, especially young women. We suggest combining BMI and BIA for obesity and overweight screening in Asian young adults. Copyright © 2016 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.

  8. Recurrent Partial Words

    Directory of Open Access Journals (Sweden)

    Francine Blanchet-Sadri

    2011-08-01

    Full Text Available Partial words are sequences over a finite alphabet that may contain wildcard symbols, called holes, which match or are compatible with all letters; partial words without holes are said to be full words (or simply words. Given an infinite partial word w, the number of distinct full words over the alphabet that are compatible with factors of w of length n, called subwords of w, refers to a measure of complexity of infinite partial words so-called subword complexity. This measure is of particular interest because we can construct partial words with subword complexities not achievable by full words. In this paper, we consider the notion of recurrence over infinite partial words, that is, we study whether all of the finite subwords of a given infinite partial word appear infinitely often, and we establish connections between subword complexity and recurrence in this more general framework.

  9. Creation of virtual reality stimulus for a psychophysiological body balance measurement

    Directory of Open Access Journals (Sweden)

    Tero Alatalo

    2008-11-01

    Full Text Available Tero Alatalo1, Martti Juhola1, Veikko Surakka1,2, Timo Tossavainen11Department of Computer Sciences, University of Tampere, Tampere, Finland; 2Department of Clinical Neurophysiology, Tampere University Hospital, Tampere, FinlandAbstract: Virtual reality methods and equipment can be used to create stimulations for several psychophysiological measurements. Such stimulations can be flexibly modified and their versatility is wide; in principle even such could be prepared that are not possible in the real physical world like virtual flying in the space. For the generation of virtual reality stimulations we constructed a three-dimensional (3D graphics engine to measure body balance variations in response to emotional stimulation. The stimulation was implemented as a virtual reality scene, where the subject watched a street view with a human figure approaching the subject at a constant speed. The functioning of the system was tested by measuring body balance variations while the approaching figure’s facial expression was angry, neutral, or happy. The results showed that our young, healthy subjects were slightly, but still statistically significantly affected by the stimulation of the approaching figure. Thus, the whole system offers a tool for controlled experimental studies for analyzing body balance, for example, during stimulating approach-withdrawal behavior. There are several opportunities to further develop new visual psychophysiological stimulations and test forms.Keywords: virtual reality stimulations, signal analysis, body balance measurements, approachwithdrawal behavior, emotions

  10. Total body composition measurements using in vivo neutron activation at the University of Washington

    International Nuclear Information System (INIS)

    Lewellen, T.L.

    1986-01-01

    The University of Washington Division of Nuclear Medicine has been using in vivo irradiation to study whole body calcium since 1969. Over 350 patients have been studied and currently five patients per week are being measured in support of research programs on bone wasting disease. (author)

  11. Lecture notes on: Electrical theory behind the measurement of body fluids with bioimpedance spectroscopy (BIS)

    DEFF Research Database (Denmark)

    Jødal, Lars

    The lecture notes describe how body fluid volumes can be measured/estimated using the technique bio-impedance spectroscopy (BIS). The opening chapters assume little or none technical/mathematical knowledge and can hopefully be read by anyone interested in the techneque. Later chapters become more...

  12. New equivalent-electrical circuit model and a practical measurement method for human body impedance.

    Science.gov (United States)

    Chinen, Koyu; Kinjo, Ichiko; Zamami, Aki; Irei, Kotoyo; Nagayama, Kanako

    2015-01-01

    Human body impedance analysis is an effective tool to extract electrical information from tissues in the human body. This paper presents a new measurement method of impedance using armpit electrode and a new equivalent circuit model for the human body. The lowest impedance was measured by using an LCR meter and six electrodes including armpit electrodes. The electrical equivalent circuit model for the cell consists of resistance R and capacitance C. The R represents electrical resistance of the liquid of the inside and outside of the cell, and the C represents high frequency conductance of the cell membrane. We propose an equivalent circuit model which consists of five parallel high frequency-passing CR circuits. The proposed equivalent circuit represents alpha distribution in the impedance measured at a lower frequency range due to ion current of the outside of the cell, and beta distribution at a high frequency range due to the cell membrane and the liquid inside cell. The calculated values by using the proposed equivalent circuit model were consistent with the measured values for the human body impedance.

  13. Long-term adherence to a local guideline on postoperative body temperature measurement: mixed methods analysis

    NARCIS (Netherlands)

    Storm-Versloot, Marja N.; Knops, Anouk M.; Ubbink, Dirk T.; Goossens, Astrid; Legemate, Dink A.; Vermeulen, Hester

    2012-01-01

    Aim To find out whether a successful multifaceted implementation approach of a local evidence-based guideline on postoperative body temperature measurements (BTM) was persistent over time, and which factors influenced long-term adherence. Methods Mixed methods analysis. Patient records were

  14. In vivo and in situ measurement and modelling of intra-body effective complex permittivity

    DEFF Research Database (Denmark)

    Nadimi, Esmaeil S; Blanes-Vidal, Victoria; Harslund, Jakob L F

    2015-01-01

    Radio frequency tracking of medical micro-robots in minimally invasive medicine is usually investigated upon the assumption that the human body is a homogeneous propagation medium. In this Letter, the authors conducted various trial programs to measure and model the effective complex permittivity e...

  15. Modelling of fillet traits based on body measurements in three Nile tilapia strains (Oreochromis niloticus L.)

    NARCIS (Netherlands)

    Rutten, M.J.M.; Bovenhuis, H.; Komen, J.

    2004-01-01

    In Nile tilapia, breeding programs focus mainly on growth, and information on genetic improvement of fillet yield is scarce. In this study, slaughter data were collected on 1215 tilapia and used to analyze the relationship between body measurements and fillet weight and fillet yield. Fish were

  16. Measurement of body composition in cats using computed tomography and dual energy X-ray absorptiometry

    DEFF Research Database (Denmark)

    Buelund, Lene E; Nielsen, Dorte H; McEvoy, Fintan

    2011-01-01

    compared CT and DEXA data from 73 healthy adult neutered domestic cats. Three approaches for measuring adipose tissue percentage from full-body CT scans were explored. By examining the frequency distribution of voxels by Hounsfield unit (HU) value, it is possible to calculate a fat index (Fat...

  17. Measurement and Interpretation of Body Mass Index during Childhood and Adolescence

    Science.gov (United States)

    Malone, Susan Kohl; Zemel, Babette S.

    2015-01-01

    The landscape of childhood health and disease has changed over the past century, and school nurses are now in a unique position to address the conditions that lead to chronic disease, such as obesity. Measuring body mass index (BMI) during childhood and adolescence is the recommended method for screening and/or monitoring obesity in school…

  18. Considerations for the measurement of core, skin and mean body temperatures.

    Science.gov (United States)

    Taylor, Nigel A S; Tipton, Michael J; Kenny, Glen P

    2014-12-01

    Despite previous reviews and commentaries, significant misconceptions remain concerning deep-body (core) and skin temperature measurement in humans. Therefore, the authors have assembled the pertinent Laws of Thermodynamics and other first principles that govern physical and physiological heat exchanges. The resulting review is aimed at providing theoretical and empirical justifications for collecting and interpreting these data. The primary emphasis is upon deep-body temperatures, with discussions of intramuscular, subcutaneous, transcutaneous and skin temperatures included. These are all turnover indices resulting from variations in local metabolism, tissue conduction and blood flow. Consequently, inter-site differences and similarities may have no mechanistic relationship unless those sites have similar metabolic rates, are in close proximity and are perfused by the same blood vessels. Therefore, it is proposed that a gold standard deep-body temperature does not exist. Instead, the validity of each measurement must be evaluated relative to one's research objectives, whilst satisfying equilibration and positioning requirements. When using thermometric computations of heat storage, the establishment of steady-state conditions is essential, but for clinically relevant states, targeted temperature monitoring becomes paramount. However, when investigating temperature regulation, the response characteristics of each temperature measurement must match the forcing function applied during experimentation. Thus, during dynamic phases, deep-body temperatures must be measured from sites that track temperature changes in the central blood volume. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. A wireless body measurement system to study fatigue in multiple sclerosis

    NARCIS (Netherlands)

    Yu, F.; Bilberg, A.; Stenager, E.; Rabotti, C.; Zhang, B.; Mischi, M.

    2012-01-01

    Fatigue is reported as the most common symptom by patients with multiple sclerosis (MS). The physiological and functional parameters related to fatigue in MS patients are currently not well established. A new wearable wireless body measurement system, named Fatigue Monitoring System (FAMOS), was

  20. Measurement of activated rCBF by the 133Xe inhalation technique: a comparison of total versus partial curve analysis

    International Nuclear Information System (INIS)

    Leli, D.A.; Katholi, C.R.; Hazelrig, J.B.; Falgout, J.C.; Hannay, H.J.; Wilson, E.M.; Wills, E.L.; Halsey, J.H. Jr.

    1985-01-01

    An initial assessment of the differential sensitivity of total versus partial curve analysis in estimating task related focal changes in cortical blood flow measured by the 133 Xe inhalation technique was accomplished by comparing the patterns during the performance of two sensorimotor tasks by normal subjects. The validity of these patterns was evaluated by comparing them to the activation patterns expected from activation studies with the intra-arterial technique and the patterns expected from neuropsychological research literature. Subjects were 10 young adult nonsmoking healthy male volunteers. They were administered two tasks having identical sensory and cognitive components but different response requirements (oral versus manual). The regional activation patterns produced by the tasks varied with the method of curve analysis. The activation produced by the two tasks was very similar to that predicted from the research literature only for total curve analysis. To the extent that the predictions are correct, these data suggest that the 133 Xe inhalation technique is more sensitive to regional flow changes when flow parameters are estimated from the total head curve. The utility of the total head curve analysis will be strengthened if similar sensitivity is demonstrated in future studies assessing normal subjects and patients with neurological and psychiatric disorders

  1. Measurement of the body composition of living gray seals by hydrogen isotope dilution

    International Nuclear Information System (INIS)

    Reilly, J.J.; Fedak, M.A.

    1990-01-01

    The body composition of living gray seals (Halichoerus grypus) can be accurately predicted from a two-step model that involves measurement of total body water (TBW) by 2 H or 3 H dilution and application of predictive relationships between body components and TBW that were derived empirically by slaughter chemical analysis. TBW was overestimated by both 2 HHO and 3 HHO dilution; mean overestimates were 2.8 +/- 0.9% (SE) with 2H and 4.0 +/- 0.6% with 3 H. The relationships for prediction of total body fat (TBF), protein (TBP), gross energy (TBGE), and ash (TBA) were as follows: %TBF = 105.1 - 1.47 (%TBW); %TBP = 0.42 (%TBW) - 4.75; TBGE (MJ) = 40.8 (mass in kg) - 48.5 (TBW in kg) - 0.4; and TBA (kg) = 0.1 - 0.008 (mass in kg) + 0.05 (TBW in kg). These relationships are applicable to gray seals of both sexes over a wide range of age and body conditions, and they predict the body composition of gray seals more accurately than the predictive equations derived from ringed seals (Pusa hispida) and from the equation of Pace and Rathbun, which has been reported to be generally applicable to mammals

  2. Total body-calcium measurements: comparison of two delayed-gamma neutron activation facilities

    International Nuclear Information System (INIS)

    Ma, R.; Ellis, K.J.; Shypailo, R.J.; Pierson, R.N. Jr.

    1999-01-01

    This study compares two independently calibrated delayed-gamma neutron activation (DGNA) facilities, one at the Brookhaven National Laboratory (BNL), Upton, New York, and the other at the Children's Nutrition Research Center (CNRC), Houston, Texas that measure total body calcium (TBCa). A set of BNL phantoms was sent to CNRC for neutron activation analysis, and a set of CNRC phantoms was measured at BNL. Both facilities showed high precision (<2%), and the results were in good agreement, within 5%. (author)

  3. Headset Bluetooth and cell phone based continuous central body temperature measurement system.

    Science.gov (United States)

    Sanches, J Miguel; Pereira, Bruno; Paiva, Teresa

    2010-01-01

    The accurate measure of the central temperature is a very important physiologic indicator in several clinical applications, namely, in the characterization and diagnosis of sleep disorders. In this paper a simple system is described to continuously measure the body temperature at the ear. An electronic temperature sensor is coupled to the microphone of a common commercial auricular Bluetooth device that sends the temperature measurements to a mobile phone to which is paired. The measurements are stored at the mobile phone and periodically sent to a medical facility by email or SMS (short messaging service).

  4. Out-of-equilibrium body potential measurements in pseudo-MOSFET for sensing applications

    Science.gov (United States)

    Benea, Licinius; Bawedin, Maryline; Delacour, Cécile; Ionica, Irina

    2018-05-01

    The aim of this paper is to present the out-of-equilibrium body potential behaviour in the Ψ-MOSFET configuration. Consistent measurements in this experimental setup succeeded in providing a substantial understanding of its characteristics in the depletion region. The final objective of this work is to envision this new measurement technique for biochemical sensor applications. Among its advantages, the most important are its simplicity, the good sensitivity, the measurement of a potential instead of a current and the low bias needed for detection compared to the conventional drain current measurements.

  5. Body posture measurement in a context of example-based teaching

    International Nuclear Information System (INIS)

    Benoit, Eric; Perrin, Stephane; Coquin, Didier

    2015-01-01

    This paper presents a measurement process of body postures operated in a context of humanoid robot learning. The basic measured quantities are the angle joints of a human skeleton and the angle joints of a humanoid robot. Due to the differences between the two mechanical structures, the measurement results are expressed into a common representation space by the way of fuzzy scales. This paper shows how the common representation space can be defined, and presents a method to match weakly defined postures with uncertain measurements of a human posture

  6. A systematic review of the measurement properties of the Body Image Scale (BIS) in cancer patients.

    Science.gov (United States)

    Melissant, Heleen C; Neijenhuijs, Koen I; Jansen, Femke; Aaronson, Neil K; Groenvold, Mogens; Holzner, Bernhard; Terwee, Caroline B; van Uden-Kraan, Cornelia F; Cuijpers, Pim; Verdonck-de Leeuw, Irma M

    2018-06-01

    Body image is acknowledged as an important aspect of health-related quality of life in cancer patients. The Body Image Scale (BIS) is a patient-reported outcome measure (PROM) to evaluate body image in cancer patients. The aim of this study was to systematically review measurement properties of the BIS among cancer patients. A search in Embase, MEDLINE, PsycINFO, and Web of Science was performed to identify studies that investigated measurement properties of the BIS (Prospero ID 42017057237). Study quality was assessed (excellent, good, fair, poor), and data were extracted and analyzed according to the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) methodology on structural validity, internal consistency, reliability, measurement error, hypothesis testing for construct validity, and responsiveness. Evidence was categorized into sufficient, insufficient, inconsistent, or indeterminate. Nine studies were included. Evidence was sufficient for structural validity (one factor solution), internal consistency (α = 0.86-0.96), and reliability (r > 0.70); indeterminate for measurement error (information on minimal important change lacked) and responsiveness (increasing body image disturbance in only one study); and inconsistent for hypothesis testing (conflicting results). Quality of the evidence was moderate to low. No studies reported on cross-cultural validity. The BIS is a PROM with good structural validity, internal consistency, and test-retest reliability, but good quality studies on the other measurement properties are needed to optimize evidence. It is recommended to include a wider variety of cancer diagnoses and treatment modalities in these future studies.

  7. The elastic body model: a pedagogical approach integrating real time measurements and modelling activities

    International Nuclear Information System (INIS)

    Fazio, C; Guastella, I; Tarantino, G

    2007-01-01

    In this paper, we describe a pedagogical approach to elastic body movement based on measurements of the contact times between a metallic rod and small bodies colliding with it and on modelling of the experimental results by using a microcomputer-based laboratory and simulation tools. The experiments and modelling activities have been built in the context of the laboratory of mechanical wave propagation of the two-year graduate teacher education programme of Palermo's University. Some considerations about observed modifications in trainee teachers' attitudes in utilizing experiments and modelling are discussed

  8. Body composition in hemodialysis patients measured by dual-energy X-ray absorptiometry

    DEFF Research Database (Denmark)

    Stenver, Doris Irene; Gotfredsen, Arne; Hilsted, J

    1995-01-01

    Dual-energy X-ray absorptiometry (DXA) measures three of the principal components of the body: fat mass, lean soft-tissue mass (comprising muscle, inner organs, and the body water), and the bone mineral content. The purpose of this study was to test the estimation capacity of DXA when it is applied...... and reduction in fat-free mass (lean soft-tissue mass plus bone mineral content) was observed by DXA. The estimation of the fat-free mass was independent of the amount of fluid loss. No significant differences in variance between the data obtained before and after the dialysis were observed. We conclude...

  9. Effect of size and composition of the body on absolute measurement of calcium in vivo

    International Nuclear Information System (INIS)

    Spinks, T.J.

    1979-01-01

    The effect of size and composition of the body on the measurement of total calcium in absolute units by neutron activation analysis is described. The neutron beam, produced from a cyclotron, was of mean energy 7.5 MeV. Counting of the activities induced in a patient was carried out with a multidetector whole body counter. Calibration of the system was achieved by using two phantoms of different sizes containing known quantities of calcium. The dimensions of various phantom sections were varied to determine the effect on efficiency of activation, an approximately linear relationship with body thickness being found. The influence of body habitus on counting efficiency was assessed by counting different patients who had been given known quantities of 42 K. The effects of (a) the non-uniform distribution of calcium and (b) the variation in density of different tissues on both activation and counting efficiency are discussed. It is estimated that the 68% confidence limits on the measurement of 49 Ca count rate per unit neutron fluence is +- 3.0% and on the measurement of calcium in grams +- 8.2%. (author)

  10. A Comparison of Locomotor Therapy Interventions: Partial-Body Weight-Supported Treadmill, Lokomat, and G-EO Training in People With Traumatic Brain Injury.

    Science.gov (United States)

    Esquenazi, Alberto; Lee, Stella; Wikoff, Amanda; Packel, Andrew; Toczylowski, Theresa; Feeley, John

    2017-09-01

    Literature in the application of gait training techniques in persons with traumatic brain injury (TBI) is limited. Current techniques require multiple staff and are physically demanding. The use of a robotic locomotor training may provide improved training capacity for this population. To examine the impact of 3 different modes of locomotor therapy on gait velocity and spatiotemporal symmetry using an end effector robot (G-EO); a robotic exoskeleton (Lokomat), and manual assisted partial-body weight-supported treadmill training (PBWSTT) in participants with traumatic brain injury. Randomized, prospective study. Tertiary rehabilitation hospital. A total of 22 individuals with ≥12 months chronic TBI with hemiparetic pattern able to walk overground without assistance at velocities between 0.2 and 0.6 m/s. Eighteen sessions of 45 minutes of assigned locomotor training. Overground walking self-selected velocity (SSV), maximal velocity (MV), spatiotemporal asymmetry ratio, 6-Minute Walk Test (6MWT), and mobility domain of Stroke Impact Scale (MSIS). Severity in walking dysfunction was similar across groups as determined by walking velocity data. At baseline, participants in the Lokomat group had a baseline velocity that was slightly slower compared with the other groups. Training elicited a statistically significant median increase in SSV for all groups compared with pretraining (Lokomat, P = .04; G-EO, P = .03; and PBWSTT, P = .02) and MV excluding the G-EO group (Lokomat, P = .04; PBWSTT, P = .03 and G-EO, P = .15). There were no pre-post significant differences in swing time, stance time, and step length asymmetry ratios at SSV or MV for any of the interventions. Mean rank in the change of SSV and MV was not statistically significantly different between groups. Participants in the G-EO and PBWSTT groups significantly improved their 6MWT posttraining (P = .04 and .03, respectively). The MSIS significantly improved only for the Lokomat group (P = .04 and .03). The

  11. Body Mass Index (BMI) in women booking for antenatal care: comparison between selfreported and digital measurements.

    LENUS (Irish Health Repository)

    Fattah, Chro

    2012-02-01

    OBJECTIVE: We set out to compare measurement of Body Mass Index (BMI) with selfreporting in women early in pregnancy. STUDY DESIGN: We studied 100 women booking for antenatal care in the first trimester with a normal ongoing pregnancy. Selfreported maternal weight and height were recorded and the Body Mass Index was calculated. Afterwards maternal weight and height were digitally measured and actual BMI was calculated. RESULTS: If selfreporting is used for BMI classification, we found that 22% of women were classified incorrectly when BMI was measured. 12% of the women who were classified as having a normal selfreported BMI were overweight and 5% classified as overweight were obese. Similar findings have been reported outside pregnancy. CONCLUSIONS: These findings have implications for clinical practice, and for research studies exploring the relationship between maternal adiposity and pregnancy complications.

  12. A wireless body measurement system to study fatigue in multiple sclerosis

    DEFF Research Database (Denmark)

    Yu, Fei; Rabotti, Chiara; Bilberg, Arne

    2012-01-01

    Fatigue is reported as the most common symptom by patients with multiple sclerosis (MS). The physiological and functional parameters related to fatigue in MS patients are currently not well established. A new wearable wireless body measurement system, named Fatigue Monitoring System (FAMOS......), was developed to study fatigue in MS. It can continuously measure electrocardiogram, body-skin temperature, electromyogram and motions of feet. The goal of this study is to test the ability of distinguishing fatigued MS patients from healthy subjects by the use of FAMOS. This paper presents the realization...... of the measurement system including the design of both hardware and dedicated signal processing algorithms. Twenty-six participants including 17 MS patients with fatigue and 9 sex- and age-matched healthy controls were included in the study for continuous 24 h monitoring. The preliminary results show significant...

  13. Associations of Body Composition Measurements with Serum Lipid, Glucose and Insulin Profile: A Chinese Twin Study

    Science.gov (United States)

    Liao, Chunxiao; Gao, Wenjing; Cao, Weihua; Lv, Jun; Yu, Canqing; Wang, Shengfeng; Zhou, Bin; Pang, Zengchang; Cong, Liming; Wang, Hua; Wu, Xianping; Li, Liming

    2015-01-01

    Objectives To quantitate and compare the associations of various body composition measurements with serum metabolites and to what degree genetic or environmental factors affect obesity-metabolite relation. Methods Body mass index (BMI), waist circumference (WC), lean body mass (LBM), percent body fat (PBF), fasting serum high density lipoprotein cholesterol (HDL-C), low density lipoprotein cholesterol (LDL-C), triglycerides (TG), total cholesterol (TC), glucose, insulin and lifestyle factors were assessed in 903 twins from Chinese National Twin Registry (CNTR). Homeostasis model assessment of insulin resistance (HOMA-IR) was calculated from fasting serum glucose and insulin. Linear regression models and bivariate structural equation models were used to examine the relation of various body composition measurements with serum metabolite levels and genetic/environmental influences on these associations, respectively. Results At individual level, adiposity measurements (BMI, WC and PBF) showed significant associations with serum metabolite concentrations in both sexes and the associations still existed in male twins when using within-MZ twin pair comparison analyses. Associations of BMI with TG, insulin and HOMA-IR were significantly stronger in male twins compared to female twins (BMI-by-sex interaction p = 0.043, 0.020 and 0.019, respectively). Comparison of various adiposity measurements with levels of serum metabolites revealed that WC explained the largest fraction of variance in serum LDL-C, TG, TC and glucose concentrations while BMI performed best in explaining variance in serum HDL-C, insulin and HOMA-IR levels. Of these phenotypic correlations, 64–81% were attributed to genetic factors, whereas 19–36% were attributed to unique environmental factors. Conclusions We observed different associations between adiposity and serum metabolite profile and demonstrated that WC and BMI explained the largest fraction of variance in serum lipid profile and insulin

  14. Development and validation of parenting measures for body image and eating patterns in childhood.

    Science.gov (United States)

    Damiano, Stephanie R; Hart, Laura M; Paxton, Susan J

    2015-01-01

    Evidence-based parenting interventions are important in assisting parents to help their children develop healthy body image and eating patterns. To adequately assess the impact of parenting interventions, valid parent measures are required. The aim of this study was to develop and assess the validity and reliability of two new parent measures, the Parenting Intentions for Body image and Eating patterns in Childhood (Parenting Intentions BEC) and the Knowledge Test for Body image and Eating patterns in Childhood (Knowledge Test BEC). Participants were 27 professionals working in research or clinical treatment of body dissatisfaction or eating disorders, and 75 parents of children aged 2-6 years, who completed the measures via an online questionnaire. Seven scenarios were developed for the Parenting Intentions BEC to describe common experiences about the body and food that parents might need to respond to in front of their child. Parents ranked four behavioural intentions, derived from the current literature on parenting risk factors for body dissatisfaction and unhealthy eating patterns in children. Two subscales were created, one representing positive behavioural intentions, the other negative behavioural intentions. After piloting a larger pool of items, 13 statements were used to construct the Knowledge Test BEC. These were designed to be factual statements about the influence of parent language, media, family meals, healthy eating, and self-esteem on child eating and body image. The validity of both measures was tested by comparing parent and professional scores, and reliability was assessed by comparing parent scores over two testing occasions. Compared with parents, professionals reported significantly higher scores on the Positive Intentions subscale and significantly lower on the Negative Intentions subscale of the Parenting Intentions BEC; confirming the discriminant validity of six out of the seven scenarios. Test-retest reliability was also confirmed as

  15. Song repertoire size correlates with measures of body size in Eurasian blackbirds

    DEFF Research Database (Denmark)

    Hesler, Nana; Mundry, Roger; Sacher, Thomas

    2012-01-01

    In most oscine bird species males possess a repertoire of different song patterns. The size of these repertoires is assumed to serve as an honest signal of male quality. The Eurasian blackbird’s (Turdus merula) song contains a large repertoire of different element types with a flexible song...... organisation. Here we investigated whether repertoire size in Eurasian blackbirds correlates with measures of body size, namely length of wing, 8th primary, beak and tarsus. So far, very few studies have investigated species with large repertoires and a flexible song organisation in this context. We found...... positive correlations, meaning that larger males had larger repertoires. Larger males may have better fighting abilities and, thus, advantages in territorial defence. Larger structural body size may also reflect better conditions during early development. Therefore, under the assumption that body size...

  16. Whole body measurements of sodium turnover in offspring of patients with sustained essential hypertension

    International Nuclear Information System (INIS)

    Henningsen, N.C.; Ohlsson, O.; Mattson, S.; Nosslin, B.; Lund Univ.; Lund Univ.

    1982-01-01

    The elimination rate (percent per day) of injected 22 Na using a whole body measurement technique was significantly lower (26%, 5.8 +- 1.5) in normotensive of borderline hypertensive offspring of essential hypertensive patients than in 15 age- and sex-matched, normotensive controls (7.3 +- 1.0). There were no significant differences in exchangeable sodium, whole body potassium or in the urinary exeretion of sodium, potassium and creatinine. The basis for the difference in turnover rate during weck 1 is probably an alteration in the cellular handling of sodium (i.e. increased intracellular sodium) in the still normotensive offspring of patients with essential hypertension. The long-term (more than 100 days) whole body retention of 22 Na was found to be only 0.1% of that injected, which justifies the use of the method on larger population groups. (orig.)

  17. Assessment of Human Ambulatory Speed by Measuring Near-Body Air Flow

    Directory of Open Access Journals (Sweden)

    Stefano Salati

    2010-09-01

    Full Text Available Accurate measurements of physical activity are important for the diagnosis of the exacerbation of chronic diseases. Accelerometers have been widely employed in clinical research for measuring activity intensity and investigating the association between physical activity and adverse health conditions. However, the ability of accelerometers in assessing physical activity intensity such as walking speed has been constrained by the inter-individual variability in sensor output and by the necessity of developing unobtrusive low-power monitoring systems. This paper will present a study aimed at investigating the accuracy of a wearable measuring system of near-body air flow to determine ambulatory speed in the field.

  18. Study of the dairy characters of lactating Murrah buffaloes on the basis of body parts measurements

    Directory of Open Access Journals (Sweden)

    Sandeep Dhillod

    2017-01-01

    Full Text Available Aim: The aim of the study was to correlate the milk yield of Murrah buffaloes with certain body parts measurements. Materials and Methods: A total of 70 lactating Murrah buffaloes were selected from Buffalo Farm, Lala Lajpat Rai University of Veterinary and Animal Science, Hisar and were randomly selected in a range from first to fifth parity. Traits studied were 305 days milk yield (MY, body weight (BW, body length (BL, muzzle width (MW, height at wither (HW, abdominal girth (AG, chest girth (CG, body depth fore, body depth rear, hip bone distance (HBD, pin bone distance (PBD, skin thickness (STK, and tail length (TL. Data were collected and statically analyzed by Pearson’s correlation method. Result: The result of this study showed that Murrah buffaloes had the average 2604.8±39.5 kg for MY, 556.1±4.9 kg for BW, and 152.2±0.8 cm for BL. This study showed that buffaloes had positive significant (p<0.05 correlation between MY and BW (0.26. Highly significant (p<0.01 correlation was observed between MY and AG (0.64, MW (0.42. Significant (p<0.01 negative correlation was observed between MY and STK (−0.79. Different body part measurements (BW, BL, HW, AG, CG, MW, TL, BD, PBD, HBD, STK were significantly correlated with each other. Conclusion: This study can be helpful as a selection tool to enhance and evaluate the production potential by setting standards of Murrah buffalo breed. BW, abdominal growth, muzzle thickness, and STK were found key factors while selecting a dairy Murrah buffalo.

  19. Radium-226 body burden in U miners by measurement of Rn in exhaled breath.

    Science.gov (United States)

    Srivastava, G K; Raghavayya, M; Kotrappa, P; Somasundaram, S

    1986-02-01

    Uranium miners were made to inhale Rn-free medical O2 and exhale through a 5.2-1 A1 chamber before reporting to work. The chamber was sealed and isolated from the sampling circuit. An electrostatic plate collected the freshly formed Rn-decay products. The subsequent programmed alpha counting of the plate yielded a Rn concentration in the exhaled breath. Assuming that the exhaled breath represents a certain fraction of the Rn produced inside the body, the body burden of 226Ra was calculated. Standardisation of this procedure and the data collected on 310 miners are discussed. The procedure is simple and applicable for routine measurements. The miner needs to be in the laboratory for only 10 min. The system is also portable for field application. For routine use, the minimum detectable concentration is 3.87 Bq X m-3 which corresponds to a body burden of 0.26 kBq in a typical miner, if one assumes the Rn release fraction from the body as 84%. The system offers a more convenient and sensitive alternative to whole-body counting of workers for 226Ra.

  20. High-frequency ultrasound measurements of the normal ciliary body and iris.

    Science.gov (United States)

    Garcia, Julian P S; Spielberg, Leigh; Finger, Paul T

    2011-01-01

    To determine the normal ultrasonographic thickness of the iris and ciliary body. This prospective 35-MHz ultrasonographic study included 80 normal eyes of 40 healthy volunteers. The images were obtained at the 12-, 3-, 6-, and 9-o'clock radial meridians, measured at three locations along the radial length of the iris and at the thickest section of the ciliary body. Mixed model was used to estimate eye site-adjusted means and standard errors and to test the statistical difference of adjusted results. Parameters included mean thickness, standard deviation, and range. Mean thicknesses at the iris root, midway along the radial length of the iris, and at the juxtapupillary margin were 0.4 ± 0.1, 0.5 ± 0.1, and 0.6 ± 0.1 mm, respectively. Those of the ciliary body, ciliary processes, and ciliary body + ciliary processes were 0.7 ± 0.1, 0.6 ± 0.1, and 1.3 ± 0.2 mm, respectively. This study provides standard, normative thickness data for the iris and ciliary body in healthy adults using ultrasonographic imaging. Copyright 2011, SLACK Incorporated.

  1. Human Body Parts Tracking and Kinematic Features Assessment Based on RSSI and Inertial Sensor Measurements

    Directory of Open Access Journals (Sweden)

    Gaddi Blumrosen

    2013-08-01

    Full Text Available Acquisition of patient kinematics in different environments plays an important role in the detection of risk situations such as fall detection in elderly patients, in rehabilitation of patients with injuries, and in the design of treatment plans for patients with neurological diseases. Received Signal Strength Indicator (RSSI measurements in a Body Area Network (BAN, capture the signal power on a radio link. The main aim of this paper is to demonstrate the potential of utilizing RSSI measurements in assessment of human kinematic features, and to give methods to determine these features. RSSI measurements can be used for tracking different body parts’ displacements on scales of a few centimeters, for classifying motion and gait patterns instead of inertial sensors, and to serve as an additional reference to other sensors, in particular inertial sensors. Criteria and analytical methods for body part tracking, kinematic motion feature extraction, and a Kalman filter model for aggregation of RSSI and inertial sensor were derived. The methods were verified by a set of experiments performed in an indoor environment. In the future, the use of RSSI measurements can help in continuous assessment of various kinematic features of patients during their daily life activities and enhance medical diagnosis accuracy with lower costs.

  2. Body composition measures of obese adolescents by the deuterium oxide dilution method and by bioelectrical impedance

    Directory of Open Access Journals (Sweden)

    C.M.M. Resende

    2011-11-01

    Full Text Available The objectives of the present study were to describe and compare the body composition variables determined by bioelectrical impedance (BIA and the deuterium dilution method (DDM, to identify possible correlations and agreement between the two methods, and to construct a linear regression model including anthropometric measures. Obese adolescents were evaluated by anthropometric measures, and body composition was assessed by BIA and DDM. Forty obese adolescents were included in the study. Comparison of the mean values for the following variables: fat body mass (FM; kg, fat-free mass (FFM; kg, and total body water (TBW; % determined by DDM and by BIA revealed significant differences. BIA overestimated FFM and TBW and underestimated FM. When compared with data provided by DDM, the BIA data presented a significant correlation with FFM (r = 0.89; P < 0.001, FM (r = 0.93; P < 0.001 and TBW (r = 0.62; P < 0.001. The Bland-Altman plot showed no agreement for FFM, FM or TBW between data provided by BIA and DDM. The linear regression models proposed in our study with respect to FFM, FM, and TBW were well adjusted. FFM obtained by DDM = 0.842 x FFM obtained by BIA. FM obtained by DDM = 0.855 x FM obtained by BIA + 0.152 x weight (kg. TBW obtained by DDM = 0.813 x TBW obtained by BIA. The body composition results of obese adolescents determined by DDM can be predicted by using the measures provided by BIA through a regression equation.

  3. Genetic association between body energy measured throughout lactation and fertility in dairy cattle.

    Science.gov (United States)

    Banos, G; Coffey, M P

    2010-02-01

    The objective of this study was to quantify the genetic association of body energy assessed throughout lactation with a cow's fertility. Nine direct and indirect body energy traits were defined at different stages of lactation. Four were daily records of energy balance, energy content, cumulative effective energy (CEE) and body condition score (BCS) calculated between lactation days 4 and 311. The other five traits included duration of negative energy balance (DNEB), rate of recovery during DNEB (RNEB), sum of negative energy balance (SNEB), nadir of energy content (NEC) and number of days from calving to NEC. Of these traits, energy balance, DNEB, RNEB and SNEB were primarily based on individual cow feed intake and milk yield, and considered direct measures of body energy. The other traits were calculated from body lipid and protein changes, predicted from BCS and live weight profiles, and were considered indirect measures of body energy. Fertility was defined by number of days between calving and commencement of luteal activity (DLA), first observed oestrus (DH) and conception (DC), and number of services per conception. A total of 957 cows in their first four lactations were considered in the study. Genetic models fitted cubic splines to define longitudinal traits (energy balance, energy content, CEE and BCS) and calculate heritability and genetic correlation with fertility. Daily heritability estimate ranges were 0.10 to 0.34, 0.35 to 0.61, 0.32 to 0.53 and 0.24 to 0.56 for energy balance, energy content, CEE and BCS, respectively, and, in most cases, tended to increase towards the middle of lactation and remain relatively stable thereafter. Of the other body energy traits, heritability of NEC (0.44) was the most notable. Statistically significant (P body energy have the strongest genetic association with cow fertility. NEC and early lactation (circa day 50) BCS and energy content are the most useful traits for selection in terms of the correlated improvement

  4. Body composition and bone mineral density measurements by using a multi-energy method

    International Nuclear Information System (INIS)

    Herve, L.

    2003-01-01

    Dual-energy X-ray absorptiometry is a major technique to evaluate bone mineral density, thus allowing diagnosis of bone decalcification ( osteoporosis). Recently, this method has proved useful to quantify body composition (fat ratio). However, these measurements suffer from artefacts which can lead to diagnosis errors in a number of cases. This work has aimed to improve both the reproducibility and the accuracy of bone mineral density and body composition measurements. To this avail, the acquisition conditions were optimised in order to ameliorate the results reproducibility and we have proposed a new method to correct inaccuracies in the determination of bone mineral density. Experimental validations yield encouraging results on both synthetic phantoms and biological samples. (author)

  5. Measurement of total body calcium in osteoporotic patients treated with salmon calcitonin

    International Nuclear Information System (INIS)

    Zanzi, I.; Thompson, K.; Cohn, S.H.

    1981-01-01

    In the past, the evaluation of therapies for osteoporosis has been limited by the lack of a suitable quantitative end point. The introduction of the technique of in vivo total body neutron activation analysis (TBNAA) has made possible the precise and accurate measurement of total body calcium (TBCa). Since almost 99 percent of TBCa is in the skeleton, TBNAA gives a direct measurement of skeletal mass. Thus, changes in skeletal mass serve as an objective criterion in the evaluation of the efficacy of the therapy in osteoporosis. Studies performed at Brookhaven National Laboratory and elsewhere have reported the use of calcitonin (CT) in the treatment of primary osteoporosis and related conditions in a limited number of patients. The physiological effects of CT as an inhibitor of bone resorption has been the rationale of its use. The results of a randomized, controlled, 2 year therapeutical trial of CT in a group of postmenopausal osteoporotic women are presented in this report

  6. Possibility of semiconductor counters application for internal contamination measurement of whole human body

    International Nuclear Information System (INIS)

    Cunic, O.; Orlic, M.; Bek-Uzarov, Dj.; Pavlovic, S.; Pavlovic, R.

    1997-01-01

    The possibility of high resolution semiconductor counters application in 'Vinca' Whole Body Counter for direct beta-gamma internal contamination measurement are discussed, assuming the following relevant characteristics: efficiency, resolution and counter price. A comparison with appropriate characteristics of NaI(Tl) crystal used in 'Vinca' WBC is treated. It is evident that the scintillation counters have the higher detection efficiency, but HPGe counters having much better resolution and recently lowest prices are also acceptable to join the existing NaI(Tl) counters with the HPGe counters in the same time, allow better spectral analyses of the human body activity and additionally more precise estimation of the equivalent doses rate which is generally a essential problem in WBC measurements. (author)

  7. Non-invasive body temperature measurement of wild chimpanzees using fecal temperature decline.

    Science.gov (United States)

    Jensen, Siv Aina; Mundry, Roger; Nunn, Charles L; Boesch, Christophe; Leendertz, Fabian H

    2009-04-01

    New methods are required to increase our understanding of pathologic processes in wild mammals. We developed a noninvasive field method to estimate the body temperature of wild living chimpanzees habituated to humans, based on statistically fitting temperature decline of feces after defecation. The method was established with the use of control measures of human rectal temperature and subsequent changes in fecal temperature over time. The method was then applied to temperature data collected from wild chimpanzee feces. In humans, we found good correspondence between the temperature estimated by the method and the actual rectal temperature that was measured (maximum deviation 0.22 C). The method was successfully applied and the average estimated temperature of the chimpanzees was 37.2 C. This simple-to-use field method reliably estimates the body temperature of wild chimpanzees and probably also other large mammals.

  8. Assessment of human body influence on exposure measurements of electric field in indoor enclosures.

    Science.gov (United States)

    de Miguel-Bilbao, Silvia; García, Jorge; Ramos, Victoria; Blas, Juan

    2015-02-01

    Personal exposure meters (PEMs) used for measuring exposure to electromagnetic fields (EMF) are typically used in epidemiological studies. As is well known, these measurement devices cause a perturbation of real EMF exposure levels due to the presence of the human body in the immediate proximity. This paper aims to model the alteration caused by the body shadow effect (BSE) in motion conditions and in indoor enclosures at the Wi-Fi frequency of 2.4 GHz. For this purpose, simulation techniques based on ray-tracing have been carried out, and their results have been verified experimentally. A good agreement exists between simulation and experimental results in terms of electric field (E-field) levels, and taking into account the cumulative distribution function (CDF) of the spatial distribution of amplitude. The Kolmogorov-Smirnov (KS) test provides a P-value greater than 0.05, in fact close to 1. It has been found that the influence of the presence of the human body can be characterized as an angle of shadow that depends on the dimensions of the indoor enclosure. The CDFs show that the E-field levels in indoor conditions follow a lognormal distribution in the absence of the human body and under the influence of BSE. In conclusion, the perturbation caused by BSE in PEMs readings cannot be compensated for by correction factors. Although the mean value is well adjusted, BSE causes changes in CDF that would require improvements in measurement protocols and in the design of measuring devices to subsequently avoid systematic errors. © 2014 Wiley Periodicals, Inc.

  9. Body Conscious? Interoceptive Awareness, Measured by Heartbeat Perception, Is Negatively Correlated with Self-Objectification

    OpenAIRE

    Ainley, Vivien; Tsakiris, Manos

    2013-01-01

    BACKGROUND: 'Self-objectification' is the tendency to experience one's body principally as an object, to be evaluated for its appearance rather than for its effectiveness. Within objectification theory, it has been proposed that self-objectification accounts for the poorer interoceptive awareness observed in women, as measured by heartbeat perception. Our study is, we believe, the first specifically to test this relationship. METHODOLOGY/PRINCIPAL FINDINGS: Using a well-validated and reliable...

  10. Individual and collective bodies: using measures of variance and association in contextual epidemiology.

    Science.gov (United States)

    Merlo, J; Ohlsson, H; Lynch, K F; Chaix, B; Subramanian, S V

    2009-12-01

    Social epidemiology investigates both individuals and their collectives. Although the limits that define the individual bodies are very apparent, the collective body's geographical or cultural limits (eg "neighbourhood") are more difficult to discern. Also, epidemiologists normally investigate causation as changes in group means. However, many variables of interest in epidemiology may cause a change in the variance of the distribution of the dependent variable. In spite of that, variance is normally considered a measure of uncertainty or a nuisance rather than a source of substantive information. This reasoning is also true in many multilevel investigations, whereas understanding the distribution of variance across levels should be fundamental. This means-centric reductionism is mostly concerned with risk factors and creates a paradoxical situation, as social medicine is not only interested in increasing the (mean) health of the population, but also in understanding and decreasing inappropriate health and health care inequalities (variance). Critical essay and literature review. The present study promotes (a) the application of measures of variance and clustering to evaluate the boundaries one uses in defining collective levels of analysis (eg neighbourhoods), (b) the combined use of measures of variance and means-centric measures of association, and (c) the investigation of causes of health variation (variance-altering causation). Both measures of variance and means-centric measures of association need to be included when performing contextual analyses. The variance approach, a new aspect of contextual analysis that cannot be interpreted in means-centric terms, allows perspectives to be expanded.

  11. An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column.

    Science.gov (United States)

    Rohlmann, Antonius; Gabel, Udo; Graichen, Friedmar; Bender, Alwina; Bergmann, Georg

    2007-06-01

    Realistic loads on a spinal implant are required among others for optimization of implant design and preclinical testing. In addition, such data may help to choose the optimal physiotherapy program for patients with such an implant and to evaluate the efficacy of aids like braces or crutches. Presently, no implant is available that can measure loads in the anterior spinal column during activities of daily life. Therefore, an implant instrumented for in vivo load measurement was developed for vertebral body replacement. The aim of this paper is to describe in detail a telemeterized implant that measures forces and moments acting on it. Six load sensors, a nine-channel telemetry unit and a coil for inductive power supply of the electronic circuits were integrated into a modified vertebral body replacement (Synex). The instrumented part of the implant is hermetically sealed. Patients are videotaped during measurements, and implant loads are displayed on and off line. The average accuracy of load measurement is better than 2% for force and 5% for moment components with reference to the maximum value of 3000 N and 20 Nm, respectively. The measuring implant described here will provide additional information on spinal loads.

  12. A combination of body condition measurements is more informative than conventional condition indices: temporal variation in body condition and corticosterone in brown tree snakes (Boiga irregularis).

    Science.gov (United States)

    Waye, Heather L; Mason, Robert T

    2008-02-01

    The body condition index is a common method for quantifying the energy reserves of individual animals. Because good body condition is necessary for reproduction in many species, body condition indices can indicate the potential reproductive output of a population. Body condition is related to glucocorticoid production, in that low body condition is correlated to high concentrations of corticosterone in reptiles. We compared the body condition index and plasma corticosterone levels of brown tree snakes on Guam in 2003 to those collected in 1992/1993 to determine whether that population still showed the chronic stress and poor condition apparent in the earlier study. We also examined the relationship between fat mass, body condition and plasma corticosterone concentrations as indicators of physiological condition of individuals in the population. Body condition was significantly higher in 2003 than in the earlier sample for mature male and female snakes, but not for juveniles. The significantly lower levels of corticosterone in all three groups in 2003 suggests that although juveniles did not have significantly improved energy stores they, along with the mature males and females, were no longer under chronic levels of stress. Although the wet season of 2002 was unusually rainy, low baseline levels of corticosterone measured in 2000 indicate that the improved body condition of snakes in 2003 is likely the result of long-term changes in prey populations rather than annual variation in response to environmental conditions.

  13. [Comparison of body temperatures in children measured using 3 different thermometers: tympanic, skin and digital axillary].

    Science.gov (United States)

    Padilla-Raygoza, Nicolás; Ruiz-Paloalto, M Laura; Díaz-Guerrero, Rosalina; Olvera-Villanueva, Georgina; Maldonado, Angélica; Raygoza-Mendoza, María Del Pilar

    2014-01-01

    To compare body temperature measurements using tympanic, skin and digital axillary thermometers. Hospitalized or outpatient children from the General Hospital Celaya, ISSSTE Hospital Clinic and General Hospital No. 4 IMSS, and the pediatric private service in Celaya, Guanajuato, from 1 day of life until 16 years old, were recruited over a one month period, after their parents signed the consent form. The order of each institution was selected by simple randomization. Body temperatures were measured in triplicate using tympanic, skin and digital axillary thermometers. The sample consisted of 554 children. The Pearson r between the tympanic and digital axillary thermometers was 0.57 to 0.65, with a positive linear relationship (P<.05); between the skin and the digital axillary thermometers, it was between 0.47 and 0.52 with a positive linearrelationship (P<.05). The intra-observer Kappa for the tympanic thermometer was 0.86, and for the inter-observer was 0.77; for the skin thermometer it was 0.82 and 0.67, respectively, and for the digital axillary thermometer it was 0.86 for intra-observer reliability and 0.78 for inter -observer reliability. Tympanic and axillary thermometers showed better precision in measuring the body temperature in children than skin thermometers. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  14. In-vivo whole body measurement of internal radioactivity in the Nordic countries

    Energy Technology Data Exchange (ETDEWEB)

    Risco Norrlid, L. del (Swedish Radiation Safety Authority (Sweden)); Halldorsson, O. (Icelandic Radiation Safety Authority (Iceland)); Holm, S. (NM and PET at Copenhagen' s Univ. Hospital (Denmark)); Huikari, J. (Radiation and Nuclear Safety Authority (Finland)); Isaksson, M. (Goeteborg Univ., Dept. Radiation Physics Sahlgren Academy (Sweden)); Lind, B. (Norwegian Radiation Protection Authority (Norway)); Roed, H. (Danish State Institute for Radiation Protection (Denmark))

    2011-02-15

    The PIANOLIB activity aims to harmonize the calibrations of the measurement equipment in the region and to evaluate the quality status of this kind of measurement by means of a proficiency test exercise. In this report the first results of the PIANOLIB activity are presented, that is, a compilation of existent regional resources for in-vivo whole body measurement and the phantom library website. In 2010 the project PIANOLIB collected the relevant information about the regional facilities, distributed the exercise instructions and managed the circulation of the phantom IRINA among the participant laboratories. The inventory within the activity has showed that the regional whole body counting assets has relatively diminished compared to 2006, the last time an inventory of the kind was made. Both the field laboratories as the stationary ones are equipped with sophisticated whole-body counting systems with Ge-or NaI-detectors. The regional competence is good and still retains experienced staff, but it is clear that a new generation is coming that needs training and exchange of experiences. It is important to keep the practice of intercomparison and NKS continues to be the best framework for supporting this kind of activity. (Author)

  15. Agreement between auricular and rectal measurements of body temperature in healthy cats.

    Science.gov (United States)

    Sousa, Marlos G; Carareto, Roberta; Pereira-Junior, Valdo A; Aquino, Monally C C

    2013-04-01

    Measurement of body temperature is a routine part of the clinical assessment of a patient. However, this procedure may be time-consuming and stressful to most animals because the standard site of temperature acquisition remains the rectal mucosa. Although an increasing number of clinicians have been using auricular temperature to estimate core body temperature, evidence is still lacking regarding agreement between these two methods in cats. In this investigation, we evaluated the agreement between temperatures measured in the rectum and ear in 29 healthy cats over a 2-week period. Temperatures were measured in the rectum (using digital and mercury-in-glass thermometers) and ear once a day for 14 consecutive days, producing 406 temperature readings for each thermometer. Mean temperature and confidence intervals were similar between methods, and Bland-Altman plots showed small biases and narrow limits of agreement acceptable for clinical purposes. The interobserver variability was also checked, which indicated a strong correlation between two near-simultaneous temperature readings. Results are consistent with auricular thermometry being a reliable alternative to rectal thermometry for assessing core body temperature in healthy cats.

  16. In-vivo whole body measurement of internal radioactivity in the Nordic countries

    International Nuclear Information System (INIS)

    Risco Norrlid, L. del; Halldorsson, O.; Holm, S.; Huikari, J.; Isaksson, M.; Lind, B.; Roed, H.

    2011-02-01

    The PIANOLIB activity aims to harmonize the calibrations of the measurement equipment in the region and to evaluate the quality status of this kind of measurement by means of a proficiency test exercise. In this report the first results of the PIANOLIB activity are presented, that is, a compilation of existent regional resources for in-vivo whole body measurement and the phantom library website. In 2010 the project PIANOLIB collected the relevant information about the regional facilities, distributed the exercise instructions and managed the circulation of the phantom IRINA among the participant laboratories. The inventory within the activity has showed that the regional whole body counting assets has relatively diminished compared to 2006, the last time an inventory of the kind was made. Both the field laboratories as the stationary ones are equipped with sophisticated whole-body counting systems with Ge-or NaI-detectors. The regional competence is good and still retains experienced staff, but it is clear that a new generation is coming that needs training and exchange of experiences. It is important to keep the practice of intercomparison and NKS continues to be the best framework for supporting this kind of activity. (Author)

  17. Results obtained with LEGe detectors applied for partial-body counting in the low-energy range (3-150 keV); Erfahrungen mit LEGe-Detektoren bei Teilkoerpermessungen im Bereich niedriger Energien (3-150 keV)

    Energy Technology Data Exchange (ETDEWEB)

    Dettmann, K. [Bundesamt fuer Strahlenschutz, Berlin (Germany)

    1997-12-01

    Due to a change in the field of duties, the Phoswich detector hitherto used for organ and partial-body scanning for measuring low-energy {gamma} radiation and X-radiation had to be replaced by a modern detector system. A key application of the new system is detection and in vivo measurement of {sup 210}Pb in the human skeleton. This method of measuring {sup 210}Pb as a long-lived daughter product of radon is applied for retrospective assessment of radiation doses emanatingfrom the radon decay chain, applied to former uranium miners (WISMUT) and members of the population living or having lived in houses with high radon concentrations. The bone activities to be expected from relevant exposures are only slightly above those of the normal {sup 210}Pb content in the bones (10-30 Bq), and the Phoswich detector system was not able to detect incorporated activity down to these low levels. The new system was also tested for its suitability and efficiency in detecting radionuclide depositions in body organs, particularly the actinides that are difficult to identify, in compliance with the relevant regulatory guide. (orig./CB) [Deutsch] In der Inkorporationsmessstelle musste auf Grund neuer Aufgabenstellungen der fuer Organ- und Teilkoerpermessungen zum Nachweis niederenergetischer {gamma}- und Roentgenstrahlung eingesetzte Phoswich-Detektor durch ein modernes Detektorsystem ersetzt werden. Ein wichtiges Einsatzgebiet des neuen Systems ist die Bestimmung von {sup 210}Pb im menschlichen Skelett ueber In-vivo-Messungen. Diese Methode der Bestimmung von {sup 210}Pb als langlebiges Folgeprodukt des Radons dient der retrospektiven Ermittlung der Exposition durch Radon-Zerfallsprodukte bei ehemaligen Uranbergleuten (WISMUT) und Personen aus der Bevoelkerung, die in Wohnhaeusern mit hohen Radonkonzentrationen leben bzw. gelebt haben. Die fuer relevante Expositionen zu erwartenden Skelettaktivitaeten liegen nur wenig ueber dem {sup 210}Pb-Normalgehalt (10-30 Bq). Mit einer

  18. Tear progression of symptomatic full-thickness and partial-thickness rotator cuff tears as measured by repeated MRI.

    Science.gov (United States)

    Kim, Yang-Soo; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Hyo-Jin; Jee, Won-Hee; Park, Chang Kyun

    2017-07-01

    The purpose of this study was to analyse the natural course of symptomatic full-thickness and partial-thickness rotator cuff tears treated non-operatively and to identify risk factors affecting tear enlargement. One hundred and twenty-two patients who received non-surgical treatment for a partial- or full-thickness supraspinatus tear were included in this study. All rotator cuff tears were diagnosed with magnetic resonance imaging (MRI), and the same modality was used for follow-up studies. Follow-up MRI was performed after at least a 6-month interval. We evaluated the correlation between tear enlargement and follow-up duration. Eleven risk factors were analysed by both univariate and multivariate analyses to identify factors that affect enlargement of rotator cuff tears. The mean follow-up period was 24.4 ± 19.5 months. Out of 122 patients, 34 (27.9%) patients had an initial full-thickness tear and 88 (72.1%) patients had a partial-thickness tear. Considering all patients together, tear size increased in 51/122 (41.8%) patients, was unchanged in 65/122 (53.3%) patients, and decreased in 6/122 (4.9%) patients. Tear size increased for 28/34 (82.4%) patients with full-thickness tears and 23/88 (26.1%) patients with partial-thickness tears. From the two groups which were followed over 12 months, a higher rate of enlargement was observed in full-thickness tears than in partial-thickness tears (6-12 months, n.s.; 12-24 months, P = 0.002; over 24 months, P rotator cuff tears and 23/88 (26.1%) of symptomatic partial-thickness tears increased in size over a follow-up period of 6-100 months. Full-thickness tears showed a higher rate of enlargement than partial-thickness tears regardless of the follow-up duration. Univariate and multivariate analyses suggested that full-thickness tear was the most reliable risk factor for tear enlargement. The clinical relevance of these observations is that full-thickness rotator cuff tears treated conservatively should be

  19. Whole-body measurements of workers occupationally exposed to radionuclides at IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Cardoso, Joaquim Carlos S.; Xavier, Marcos

    2015-01-01

    The intake of radioactive material by workers can occur in the radiopharmaceuticals production, during the handling of these in the medical fields (nuclear medicine) and in biological and research laboratories. The workers who work in areas where exposures are significant are routinely monitored to demonstrate that the workers are receiving adequate protection from internal contamination. Direct measurements of whole-body and thyroid contents provide an estimate of the activity of these radionuclides in the potentially exposed workers. The whole-body measurements of the workers, trainees and visitors are routinely performed by the In Vivo Monitoring Laboratory (LMIV) of the Energy and Nuclear Research Institute (IPEN/CNEN-SP). The frequency of measurements is defined by the Radioprotection Service (SRP) and the Dose Calculation Group of IPEN. For this purpose LMIV has two counters, whole body. NaITl (8 x 4”), and thyroid one, NaITl (3 x 3”). The system was calibrated in energy and efficiency, with calibration sources of Eu-152, Am-241 and Co-60 with gamma emissions between 59.54 and 1408.08 keV, positioned within Alderson Research Labs. anthropomorphic phantom. The background measures were obtained of worker's spectrum that was not exposed occupationally yet. The concepts adopted in the HPS N13.30 Standard and proposed in ISO documents for standardization were used for activity measurements. During the period January 2010 to December 2014, approximately 4500 measurements had been carried in workers who develop tasks related to the production and research. The activities of the radionuclides and the workers' tasks relationship had been evaluated. (author)

  20. Whole-body measurements of workers occupationally exposed to radionuclides at IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Cardoso, Joaquim Carlos S.; Xavier, Marcos

    2013-01-01

    The intake of radioactive material by workers can occur in the radiopharmaceuticals production, during the handling of these in the medical fields (nuclear medicine) and in biological and research laboratories. The workers who work in areas where exposures are significant are routinely monitored to demonstrate that the workers are receiving adequate protection from internal contamination. Direct measurements of whole-body and thyroid contents provide an estimate of the activity of these radionuclides in the potentially exposed workers. The whole-body measurements of the workers, trainees and visitors are routinely performed by the In Vivo Monitoring Laboratory (LMIV) of the Energy and Nuclear Research Institute (IPEN/CNEN-SP). The frequency of measurements is defined by the Radioprotection Service (SRP) and the Dose Calculation Group of IPEN. For this purpose LMIV has two counters, whole body. NaIT1 (8x4″), and thyroid one, NaIT1 (3x3″). The system was calibrated in energy and efficiency, with calibration sources of Eu-152, Am-241 and Co-60 with gamma emissions between 59.54 and 1408.08 keV, positioned within Alderson Research Labs. anthropomorphic phantom. The background measures were obtained of worker's spectrum that wasn't exposed occupationally yet. The concepts adopted in the HPS N13.30 Standard and proposed in ISO documents for standardization were used for activity measurements. During the period January 2007 to December 2012, approximately 6700 measurements had been carried in workers who develop tasks related to the production and research. The activities of the radionuclides and the workers' tasks relationship had been evaluated. (author)

  1. Measurement of asbestos bodies in lung tissue of autopsy cases diagnosed with primary lung cancer

    International Nuclear Information System (INIS)

    Idei, Yuka; Kamada, Satoe; Matsumoto, Shoji; Ohnishi, Kazuo; Kitazawa, Riko; Kitazawa, Sohei

    2007-01-01

    To investigate the relation between asbestos-related lung cancer and the concentration of asbestos bodies in lung tissue, we analyzed the concentration in 24 autopsy cases diagnosed with primary lung cancer, with regard to the gender, age, histological type of lung cancer and occupation of each case. The asbestos bodies were measured according to Kohyama's method. Positive cases (more than 5,000 bodies per 1 g of dry lung tissue) were further analyzed for asbestosis and pleural plaques by chest X-ray and chest CT. Two cases exhibited more than 5,000 bodies, five cases between 1,000 and 5,000, and seventeen cases less than 1,000. The occupation of the two positive cases was not informative: one demonstrated neither asbestosis nor pleural plaques, and the other showed only pleural plaques. Although the number of cases of asbestos-related lung cancer is minimal among all lung cancer cases, the number of the former may exceed that of mesothelioma patients. Not only physicians but also radiologists, surgeons and pathologists need to collaborate in the diagnosis of asbestos-related lung cancer. (author)

  2. Theoretical study on the inverse modeling of deep body temperature measurement

    International Nuclear Information System (INIS)

    Huang, Ming; Chen, Wenxi

    2012-01-01

    We evaluated the theoretical aspects of monitoring the deep body temperature distribution with the inverse modeling method. A two-dimensional model was built based on anatomical structure to simulate the human abdomen. By integrating biophysical and physiological information, the deep body temperature distribution was estimated from cutaneous surface temperature measurements using an inverse quasilinear method. Simulations were conducted with and without the heat effect of blood perfusion in the muscle and skin layers. The results of the simulations showed consistently that the noise characteristics and arrangement of the temperature sensors were the major factors affecting the accuracy of the inverse solution. With temperature sensors of 0.05 °C systematic error and an optimized 16-sensor arrangement, the inverse method could estimate the deep body temperature distribution with an average absolute error of less than 0.20 °C. The results of this theoretical study suggest that it is possible to reconstruct the deep body temperature distribution with the inverse method and that this approach merits further investigation. (paper)

  3. Whole-body profile scanner for in vivo quantitative activity measurement

    International Nuclear Information System (INIS)

    Bergmann, H.

    1978-01-01

    A whole-body profile scanner has been developed by fitting parallel slit collimators to a shadow shield whole-body counter. Sensitivity, uniformity and resolution measurements were performed using a number of different counting conditions. It is shown that improved accuracy of activity measurements is obtained by using a wide window counting technique for low and medium energy gamma emitters (99m Tc, 131 I), whereas a photopeak window should be used for high energy gamma emitters (47 Ca). Due to the finite spatial resolution of the system a systematic error in evaluating regional activities from the counting rate profile occurs which is characterized by a spatial spillover factor. The spatial spillover factor is measured and is subsequently used to calculate the error on basis of a simple model. It is shown that only small errors are caused by spatial spillover when the length of a region is at least three times the full width half maximum of the point spread function. Applying the above mentioned simple rules it is concluded that profile scanning is a sensitive and accurate technique for activity measurements in vivo. Two examples of clinical applications (measurement of bone accretion rates of calcium and Tc-pyrophosphate, regional radioiodine retention in patients with thyroid carcinoma) and a review of the papers on profile scanning demonstrate the types of investigations in which profile scanning is superior to alternative techniques. (author)

  4. Discriminative ability of total body bone-mineral measured by dual photon absorptiometry

    International Nuclear Information System (INIS)

    Gotfredsen, A.; Poedenphant, J.; Nilas, L.; Christiansen, C.

    1989-01-01

    We investigated the descriminative ability of total body bone-mineral expressed as the total body bone-density (TBBD) measured by dual photon absorptiometry (DPA) in 79 healthy premenopausal women, 27 healthy postmenopausal women, and 120 female osteoporotic fracture patients presenting with either Colles' fracture, vertebral fracture or femoral neck-fracture. TBBD was compared to the bone-mineral density of the lumbar spine (BMD spine ) also measured by DPA, and to the bone-mineral content of the forearms (BMC forearm ) measured by single photon absorptiometry (SPA). TBBD, BMD spine and BMC forearm showed that all the fracture patient groups had significantly reduced bone-mass. Using receiver operating characteristic (ROC) analysis, we found that TBBD had a tendency towards better discriminative ability than BMD spine or BMC forearm with regard to the discrimination between healthy premenopausal women and the three types of osteoporotic fractures. BMC forearm had an intermediate position, whereas BMD spine had the smallest discriminative ability. TBBD also discriminated better between healthy postmenopausal women and hip-fracture patients than BMD spine or BMC forearm , whereas there was no significant difference between the three methods regarding the discrimination between the healthy postmenopausal women and the Colles' and spinal fracture patients. We conclude that the TBBD measurement by DPA has a discriminative potential which is better than the local spine or forearm measurements. (author)

  5. A Study on the Reliability of Sasang Constitutional Body Trunk Measurement

    Directory of Open Access Journals (Sweden)

    Eunsu Jang

    2012-01-01

    Full Text Available Objective. Body trunk measurement for human plays an important diagnostic role not only in conventional medicine but also in Sasang constitutional medicine (SCM. The Sasang constitutional body trunk measurement (SCBTM consists of the 5-widths and the 8-circumferences which are standard locations currently employed in the SCM society. This study suggests to what extent a comprehensive training can improve the reliability of the SCBTM. Methods. We recruited 10 male subjects and 5 male observers with no experience of anthropometric measurement. We conducted measurements twice before and after a comprehensive training. Relative technical error of measurement (%TEMs was produced to assess intra and inter observer reliabilities. Results. Post-training intra-observer %TEMs of the SCBTM were 0.27% to 1.85% reduced from 0.27% to 6.26% in pre-training, respectively. Post-training inter-observer %TEMs of those were 0.56% to 1.66% reduced from 1.00% to 9.60% in pre-training, respectively. Post-training % total TEMs which represent the whole reliability were 0.68% to 2.18% reduced from maximum value of 10.18%. Conclusion. A comprehensive training makes the SCBTM more reliable, hence giving a sufficiently confident diagnostic tool. It is strongly recommended to give a comprehensive training in advance to take the SCBTM.

  6. A study on the reliability of sasang constitutional body trunk measurement.

    Science.gov (United States)

    Jang, Eunsu; Kim, Jong Yeol; Lee, Haejung; Kim, Honggie; Baek, Younghwa; Lee, Siwoo

    2012-01-01

    Objective. Body trunk measurement for human plays an important diagnostic role not only in conventional medicine but also in Sasang constitutional medicine (SCM). The Sasang constitutional body trunk measurement (SCBTM) consists of the 5-widths and the 8-circumferences which are standard locations currently employed in the SCM society. This study suggests to what extent a comprehensive training can improve the reliability of the SCBTM. Methods. We recruited 10 male subjects and 5 male observers with no experience of anthropometric measurement. We conducted measurements twice before and after a comprehensive training. Relative technical error of measurement (%TEMs) was produced to assess intra and inter observer reliabilities. Results. Post-training intra-observer %TEMs of the SCBTM were 0.27% to 1.85% reduced from 0.27% to 6.26% in pre-training, respectively. Post-training inter-observer %TEMs of those were 0.56% to 1.66% reduced from 1.00% to 9.60% in pre-training, respectively. Post-training % total TEMs which represent the whole reliability were 0.68% to 2.18% reduced from maximum value of 10.18%. Conclusion. A comprehensive training makes the SCBTM more reliable, hence giving a sufficiently confident diagnostic tool. It is strongly recommended to give a comprehensive training in advance to take the SCBTM.

  7. Equations based on anthropometry to predict body fat measured by absorptiometry in schoolchildren and adolescents.

    Science.gov (United States)

    Ortiz-Hernández, Luis; Vega López, A Valeria; Ramos-Ibáñez, Norma; Cázares Lara, L Joana; Medina Gómez, R Joab; Pérez-Salgado, Diana

    To develop and validate equations to estimate the percentage of body fat of children and adolescents from Mexico using anthropometric measurements. A cross-sectional study was carried out with 601 children and adolescents from Mexico aged 5-19 years. The participants were randomly divided into the following two groups: the development sample (n=398) and the validation sample (n=203). The validity of previously published equations (e.g., Slaughter) was also assessed. The percentage of body fat was estimated by dual-energy X-ray absorptiometry. The anthropometric measurements included height, sitting height, weight, waist and arm circumferences, skinfolds (triceps, biceps, subscapular, supra-iliac, and calf), and elbow and bitrochanteric breadth. Linear regression models were estimated with the percentage of body fat as the dependent variable and the anthropometric measurements as the independent variables. Equations were created based on combinations of six to nine anthropometric variables and had coefficients of determination (r 2 ) equal to or higher than 92.4% for boys and 85.8% for girls. In the validation sample, the developed equations had high r 2 values (≥85.6% in boys and ≥78.1% in girls) in all age groups, low standard errors (SE≤3.05% in boys and ≤3.52% in girls), and the intercepts were not different from the origin (p>0.050). Using the previously published equations, the coefficients of determination were lower, and/or the intercepts were different from the origin. The equations developed in this study can be used to assess the percentage of body fat of Mexican schoolchildren and adolescents, as they demonstrate greater validity and lower error compared with previously published equations. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  8. Relationships Between Live Body and Carcass Measurements and Carcass Components in Omani Sheep

    Directory of Open Access Journals (Sweden)

    O. Mahgoub

    1998-01-01

    Full Text Available Thirty two Omani sheep including eight intact males. 16 castrated males and eight intact females were fed ad libitum a concentrate diet (l6% CP plus chopped Rhodesgrass hay (8% CP from weaning until slaughter at an average weight of 26 kg. Correlation and regression analyses were carried out to evaluate relationships between live body and carcass measurements with major body components. Generally there were positive correlations between slaughter weight, empty body weight (EBW and hot carcass weight with total carcass muscle (r2 =0.57, 0.59, 0.59. fat (r2= 0.47, 0.48, 0.68 and bone (r2 = 0.51, 0.44, 0.31 contents respectively. There were also positive correlations (r2 = 0.44- 0.59 between linear live body and carcass measurements with carcass muscle content. The depth of tissue over the 11th rib (GR had a high positive correlation (r2= 0.67 with total carcass fat content. The weight of most individual bones and muscles had positive correlations (r2=0.39 - 0.85 with carcass muscle and bone content. There was a positive correlation between weight chuck (r2 = 0.62, brisket and shank (r2< 0.38, leg (r2 = 0.79 and loin (r2 = 0.45 carcass cuts with total carcass muscle content. Muscle content in all carcass cuts had a positive correlation (r2 = 0.46-0.86 with total carcass muscle content. Bone content in all carcass cuts had a high positive correlation (r2 = 0.46-0.90 with the total carcass bone content. A 3-variahle (body length,  chest depth and leg length and a 4-variable (hot carcass weight , hook width,  rib width and GR models were generated which accounted for 84% and 70% of the variation in the total muscle content, respectively. This study showed that live body and carcass measurements have significant relationships with carcass components in Omani sheep. These relationships may be utilized for prediction of carcass composition in live animals as well as for carcass quality assessment.

  9. Implant-supported mandibular removable partial dentures; patient-based outcome measures in relation to implant position

    NARCIS (Netherlands)

    Jensen, Charlotte; Raghoebar, Gerry M.; Kerdijk, Wouter; Meijer, Henny J. A.; Cune, Marco S.

    2016-01-01

    Objectives: To assess the benefits of implant support to Removable Partial Dentures (RPD) in patients with a bilateral free-ending situation in the mandible and to determine the most favorable implant position: the premolar (PM) or the molar (M) region. Methods: Thirty subjects with a bilateral

  10. Fetal subcutaneous tissue measurements in pregnancy as a predictor of neonatal total body composition.

    Science.gov (United States)

    O'Connor, Clare; Doolan, Anne; O'Higgins, Amy; Segurado, Ricardo; Sheridan-Pereiraet, Margaret; Turner, Michael J; Stuart, Bernard; Kennelly, Máireád M

    2014-10-01

    The purpose of this study was to examine the relationship between prenatal measures of subcutaneous tissue as surrogate markers of fetal nutritional status and correlate them with neonatal total body composition. This prospective longitudinal study of 62 singleton pregnancies obtained serial biometry and subcutaneous tissue measurements at 28, 33 and 38 weeks gestation. These measurements were then correlated with neonatal body composition, which was analysed using the PEAPOD™ Infant Body Composition System (Cosmed USA, Concord, CA, USA). At 38 weeks gestation, fetal abdominal subcutaneous tissue (FAST) in millimetres was significantly associated with infant fat mass at delivery (+64 g per mm of FAST, p < 0.001). Thigh fat (TF) at 28 weeks gestation was associated with infant fat mass at delivery (+79 g/mm TF, p = 0.023). TF at 38 weeks gestation was associated with infant fat mass (+63/mm TF, p = 0.004). TF and FAST at 38 weeks were also predictive of both birth weight and increased abdominal circumference (AC) (p = 0.001) with FAST measurement predicting an additional 5.7 mm in AC per millimetre of FAST (p = 0.002) and TF predicting an additional 6.9 mm per mm of TF (p = 0.002). We believe that this study further validates the use of prenatal measures of subcutaneous tissue and may help to highlight fetuses at risk of newborn adiposity and metabolic syndrome. © 2014 John Wiley & Sons, Ltd.

  11. Novel Zero-Heat-Flux Deep Body Temperature Measurement in Lower Extremity Vascular and Cardiac Surgery.

    Science.gov (United States)

    Mäkinen, Marja-Tellervo; Pesonen, Anne; Jousela, Irma; Päivärinta, Janne; Poikajärvi, Satu; Albäck, Anders; Salminen, Ulla-Stina; Pesonen, Eero

    2016-08-01

    The aim of this study was to compare deep body temperature obtained using a novel noninvasive continuous zero-heat-flux temperature measurement system with core temperatures obtained using conventional methods. A prospective, observational study. Operating room of a university hospital. The study comprised 15 patients undergoing vascular surgery of the lower extremities and 15 patients undergoing cardiac surgery with cardiopulmonary bypass. Zero-heat-flux thermometry on the forehead and standard core temperature measurements. Body temperature was measured using a new thermometry system (SpotOn; 3M, St. Paul, MN) on the forehead and with conventional methods in the esophagus during vascular surgery (n = 15), and in the nasopharynx and pulmonary artery during cardiac surgery (n = 15). The agreement between SpotOn and the conventional methods was assessed using the Bland-Altman random-effects approach for repeated measures. The mean difference between SpotOn and the esophageal temperature during vascular surgery was+0.08°C (95% limit of agreement -0.25 to+0.40°C). During cardiac surgery, during off CPB, the mean difference between SpotOn and the pulmonary arterial temperature was -0.05°C (95% limits of agreement -0.56 to+0.47°C). Throughout cardiac surgery (on and off CPB), the mean difference between SpotOn and the nasopharyngeal temperature was -0.12°C (95% limits of agreement -0.94 to+0.71°C). Poor agreement between the SpotOn and nasopharyngeal temperatures was detected in hypothermia below approximately 32°C. According to this preliminary study, the deep body temperature measured using the zero-heat-flux system was in good agreement with standard core temperatures during lower extremity vascular and cardiac surgery. However, agreement was questionable during hypothermia below 32°C. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Non-invasive techniques for measuring body composition: state of the art and future prospects

    Energy Technology Data Exchange (ETDEWEB)

    Cohn, S.H.

    1985-01-01

    In the past 20 years, in vivo analysis of body elements by neutron activation has become an important tool in medical research. In particular, it provides a much needed means to make quantitative assessments of body composition of human beings in vivo. The data are useful both for basic physiological understanding and for diagnosis and management of a variety of diseases and disorders. This paper traces the development of the in vivo neutron activation technique from basic systems to the present state of the art facilities. A scan of some of the numerous clinical applications that have been made with this technique, reveals the broad potentialities of in vivo neutron activation. The paper also considers alternative routes of future development and raises some of the questions now faced in making the techniques more widely available to both medical practitioners and medical investigators. In vivo neutron activation has opened a new era of both clinical diagnosis and therapy evaluation, and investigation into the modelling of body composition. The techniques are new, but it is already clear that considerable strides can be made in increasing accuracy and precision, increasing the number of elements susceptible to measurement, and reducing the dose required for the measurement. 18 refs., 7 figs.

  13. Non-invasive techniques for measuring body composition: state of the art and future prospects

    International Nuclear Information System (INIS)

    Cohn, S.H.

    1985-01-01

    In the past 20 years, in vivo analysis of body elements by neutron activation has become an important tool in medical research. In particular, it provides a much needed means to make quantitative assessments of body composition of human beings in vivo. The data are useful both for basic physiological understanding and for diagnosis and management of a variety of diseases and disorders. This paper traces the development of the in vivo neutron activation technique from basic systems to the present state of the art facilities. A scan of some of the numerous clinical applications that have been made with this technique, reveals the broad potentialities of in vivo neutron activation. The paper also considers alternative routes of future development and raises some of the questions now faced in making the techniques more widely available to both medical practitioners and medical investigators. In vivo neutron activation has opened a new era of both clinical diagnosis and therapy evaluation, and investigation into the modelling of body composition. The techniques are new, but it is already clear that considerable strides can be made in increasing accuracy and precision, increasing the number of elements susceptible to measurement, and reducing the dose required for the measurement. 18 refs., 7 figs

  14. Theoretical simulation of the dual-heat-flux method in deep body temperature measurements.

    Science.gov (United States)

    Huang, Ming; Chen, Wenxi

    2010-01-01

    Deep body temperature reveals individual physiological states, and is important in patient monitoring and chronobiological studies. An innovative dual-heat-flux method has been shown experimentally to be competitive with the conventional zero-heat-flow method in its performance, in terms of measurement accuracy and step response to changes in the deep temperature. We have utilized a finite element method to model and simulate the dynamic process of a dual-heat-flux probe in deep body temperature measurements to validate the fundamental principles of the dual-heat-flux method theoretically, and to acquire a detailed quantitative description of the thermal profile of the dual-heat-flux probe. The simulation results show that the estimated deep body temperature is influenced by the ambient temperature (linearly, at a maximum rate of 0.03 °C/°C) and the blood perfusion rate. The corresponding depth of the estimated temperature in the skin and subcutaneous tissue layer is consistent when using the dual-heat-flux probe. Insights in improving the performance of the dual-heat-flux method were discussed for further studies of dual-heat-flux probes, taking into account structural and geometric considerations.

  15. Open-Ended Measurement of Whole-Body Movement: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Finn, Michael T. M.

    2018-02-01

    Full Text Available As the importance of embodiment emerges for psychology, there is a need to advance methodology for measuring the dynamics of movement in an open-ended fashion. Such a tool should be versatile across contexts and track spontaneous and natural movement with minimal constraints. We test the feasibility of a method for measuring whole-body movement over time that attempts to meet this need. We use a motion capture system comprised of two Microsoft Kinect version 2.0 cameras and iPiSoft Motion Capture software, and compare its estimates of magnitude rotational velocity and whole-body movement complexity (multivariate multiscale sample entropy; MMSE to that of a gold standard motion capture system across a variety of movement sequences. The candidate system satisfactorily estimated the instantaneous velocity of 13 body segments in agreement with the gold standard system across movement sequences demonstrating initial feasibility of this process. Summary calculations of velocity by sequence and MMSE calculations were also in high agreement with the gold standard, crucially suggesting that the candidate system could pick up on the complex dynamics of movement over time. The candidate system was feasible and demonstrates preliminary validity for general use in the tracking of continuous human movement for clinical and experimental psychology. We also provide R code and sample data for the importing and processing of movement data exported from iPiSoft Motion Capture Studio.

  16. Calibration of CDTN-whole body counter for in vivo measurements of I-131

    International Nuclear Information System (INIS)

    Oliveira, Cassio M.; Silva, Tania V. da; Alonso, Thessa C.; Squair, Peterson L.

    2009-01-01

    Iodine-131 is frequently used in nuclear medicine services for diagnosis and therapy of thyroid diseases. Furthermore, the Nuclear Technology Development Centre (CDTN/CNEN), in Belo Horizonte, uses Iodine-131 for radiobiology and radiopharmacy researches. The increasing use of this radionuclide for medical and research purposes as well as its high volatility creates a demand for feasible methodologies to perform occupational control of internal contamination. Therefore the objective this work is to develop methods of in vivo bioassay for evaluation Iodine-131 incorporation by using NaI(Tl) 6'' x 4'' scintillation detector of the CDTN-Whole Body Counter (WBC). Such detector was calibrated for in vivo measurements with a neck-thyroid phantom, simulating Iodine-131 incorporation. The chosen counting geometry was lying under monitoring bed of CDTNWBC. A methodology for bioassay data interpretation, based on standard ICRP 56 model was established with software AIDE (activity internal dose estimate) version 6.0. It was concluded that in vivo measurements have sufficient sensitivity for the monitoring of Iodine-131 through CDTN-Whole Body Counter. Therefore, the CDTN-Whole Body Counter equipment of Belo Horizonte are ready to attend suspicion intake cases of Iodine- 131 (author)

  17. Calibration of CDTN-whole body counter for in vivo measurements of I-131

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cassio M.; Silva, Tania V. da; Alonso, Thessa C.; Squair, Peterson L. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN/MG), Belo Horizonte, MG (Brazil)], e-mail: cmo@cdtn.br

    2009-07-01

    Iodine-131 is frequently used in nuclear medicine services for diagnosis and therapy of thyroid diseases. Furthermore, the Nuclear Technology Development Centre (CDTN/CNEN), in Belo Horizonte, uses Iodine-131 for radiobiology and radiopharmacy researches. The increasing use of this radionuclide for medical and research purposes as well as its high volatility creates a demand for feasible methodologies to perform occupational control of internal contamination. Therefore the objective this work is to develop methods of in vivo bioassay for evaluation Iodine-131 incorporation by using NaI(Tl) 6'' x 4'' scintillation detector of the CDTN-Whole Body Counter (WBC). Such detector was calibrated for in vivo measurements with a neck-thyroid phantom, simulating Iodine-131 incorporation. The chosen counting geometry was lying under monitoring bed of CDTNWBC. A methodology for bioassay data interpretation, based on standard ICRP 56 model was established with software AIDE (activity internal dose estimate) version 6.0. It was concluded that in vivo measurements have sufficient sensitivity for the monitoring of Iodine-131 through CDTN-Whole Body Counter. Therefore, the CDTN-Whole Body Counter equipment of Belo Horizonte are ready to attend suspicion intake cases of Iodine- 131 (author)

  18. Assessment of body fat composition in crossbred Angus × Nellore using biometric measurements.

    Science.gov (United States)

    Fonseca, M A; Tedeschi, L O; Filho, S C Valadares; De Paula, N F; Villadiego, F A C; Junior, J M Silva; Abreu, D C; Chizzotti, M L

    2017-12-01

    This study was conducted to assess the body and empty body fat physical and chemical composition through biometric measurements (BM) as well as postmortem measurements taken in 40 F Angus × Nellore bulls and steers. The animals used were 12.5 ± 0.51 mo of age, with an average shrunk BW of 233 ± 23.5 and 238 ± 24.6 kg for bulls and steers, respectively. Animals were fed 60:40 ratio of corn silage to concentrate diets. Eight animals (4 bulls and 4 steers) were slaughtered at the beginning of the trial, and the remaining animals were randomly assigned to a 1 + 2 × 3 factorial arrangement (1 reference group, 2 sexes, and 3 slaughter weights). The remaining animals were slaughtered when the average BW of the group reached 380 ± 19.5 (6 bulls and 5 steers), 440 ± 19.2 (6 bulls and 5 steers), and 500 ± 19.5 kg (5 bulls and 5 steers). Before the slaughter, the animals were led through a squeeze chute in which BM were taken, including hook bone width (HBW), pin bone width, abdomen width (AW), body length (BL), rump height, height at the withers, pelvic girdle length (PGL), rib depth (RD), girth circumference (GC), rump depth, body diagonal length (BDL), and thorax width. Additionally, the following postmortem measurements were obtained: total body surface (TBS), body volume (BV), subcutaneous fat (SF), internal physical fat (InF), intermuscular fat, carcass physical fat (CF), empty body physically separable fat (EBF), carcass chemical fat (CFch), empty body chemical fat (EBFch), fat thickness in the 12th rib, and 9th to 11th rib section fat. The equations were developed using a stepwise procedure to select the variables that should enter into the model. The and root mean square error (RMSE) were used to account for precision and accuracy. The ranges for and RMSE were 0.852 to 0.946 and 0.0625 to 0.103 m, respectively for TBS; 0.942 to 0.998 and 0.004 to 0.022 m, respectively, for BV; 0.767 to 0.967 and 2.70 to 3.24 kg, respectively, for SF; 0.816 to 0.900 and 3

  19. A Longitudinal Analysis of Adolescent Smoking: Using Smoking Status to Differentiate the Influence of Body Weight Measures

    Science.gov (United States)

    Hong, Traci; Johnson, Carolyn

    2013-01-01

    Background: Previous research has reported mixed results on the association between body weight measures (ie, perception of weight and weight loss goal) and cigarette smoking prevalence--and how these associations vary by sex and race. This longitudinal study assessed the relationship between these 2 body weight measures and smoking prevalence by…

  20. Combining Body Mass Index With Measures of Central Obesity in the Assessment of Mortality in Subjects With Coronary Disease

    DEFF Research Database (Denmark)

    Coutinho, Thais; Goel, Kashish; Corrêa de Sá, Daniel

    2013-01-01

    This study sought to assess the mortality risk of patients with coronary artery disease (CAD) based ona combination of body mass index (BMI) with measures of central obesity.......This study sought to assess the mortality risk of patients with coronary artery disease (CAD) based ona combination of body mass index (BMI) with measures of central obesity....

  1. Measures of Body Size and Composition and Risk of Incident Atrial Fibrillation in Older People

    Science.gov (United States)

    Karas, Maria G.; Yee, Laura M.; Biggs, Mary L.; Djoussé, Luc; Mukamal, Kenneth J.; Ix, Joachim H.; Zieman, Susan J.; Siscovick, David S.; Gottdiener, John S.; Rosenberg, Michael A.; Kronmal, Richard A.; Heckbert, Susan R.; Kizer, Jorge R.

    2016-01-01

    Various anthropometric measures, including height, have been associated with atrial fibrillation (AF). This raises questions about the appropriateness of using ratio measures such as body mass index (BMI), which contains height squared in its denominator, in the evaluation of AF risk. Among older adults, the optimal anthropometric approach to risk stratification of AF remains uncertain. Anthropometric and bioelectrical impedance measures were obtained from 4,276 participants (mean age = 72.4 years) free of cardiovascular disease in the Cardiovascular Health Study. During follow-up (1989–2008), 1,050 cases of AF occurred. BMI showed a U-shaped association, whereas height, weight, waist circumference, hip circumference, fat mass, and fat-free mass were linearly related to incident AF. The strongest adjusted association occurred for height (per each 1-standard-deviation increment, hazard ratio = 1.38, 95% confidence interval: 1.25, 1.51), which exceeded all other measures, including weight (hazard ratio = 1.21, 95% confidence interval: 1.13, 1.29). Combined assessment of log-transformed weight and height showed regression coefficients that departed from the 1 to −2 ratio inherent in BMI, indicating a loss of predictive information. Risk estimates for AF tended to be stronger for hip circumference than for waist circumference and for fat-free mass than for fat mass, which was explained largely by height. These findings highlight the prominent role of body size and the inadequacy of BMI as determinants of AF in older adults. PMID:27188936

  2. Molecular cloning, expression and characterization of bovine UQCC and its association with body measurement traits

    DEFF Research Database (Denmark)

    Liu, Yongfeng; Zan, Linsen; Zhao, Shuanping

    2010-01-01

    effects on the BL (p = 0.0047) and CD (p = 0.0454. Regarding association analysis of combination of the two SNPs, there are significant effects on the BL (p = 0.0215), CD (p = 0.0282) and PBW (p = 0.0329) in the total population. The results suggest that the UQCC gene is a candidate gene of body...... measurement traits in bovine reproduction and breeding, and provide data for establishing of an animal model using cattle to study big animal body type....... models of height as well as other stature indexes. We have cloned the cDNA sequence coding UQCC gene in bovine. Genomic structural analysis indicated that bovine UQCC shares a high similarity with human UQCC. Furthermore, Real-Time PCR analysis show that the expression of bovine UQCC is remarkably...

  3. Holographic interferometry applied to the measurement of displacements of the interior points of transparent bodies.

    Science.gov (United States)

    Sciammarella, C A; Gilbert, J A

    1976-09-01

    Utilizing the light scattering property of transparent media, holographic interferometry is applied to the measurement of displacement at the interior planes of three dimensional bodies. The use of a double beam illumination and the introduction of a fictitious displacement make it feasible to obtain information corresponding to components of displacement projected on the scattering plane. When the proposed techniques are invoked, it is possible to eliminate the use of a matching index of refraction fluid in many problems involving symmetrically loaded prismatic bodies. Scattered light holographic interferometry is limited in its use to small changes in the index of refraction and to low values of relative retardation. In spite of these restrictions, a large number of technical problems in both statics and dynamics can be solved.

  4. Alternatives to isotope ratio mass spectrometry for the measurement of deuterium content of body water

    International Nuclear Information System (INIS)

    Bluck, L.J.C.

    2000-01-01

    The measurement of breast milk intake using the isotope dilution techniques is now well established. The methodology involves the administration of a bolus of tracer followed by observation of the kinetics of its passage though the system. For example in the popular 'dose to the mother' method a dose of labeled water is administered to the mother, and over the following days samples of body fluids are taken and the concentration of tracer determined in order to establish the rate of loss of tracer from her body. Likewise samples are taken from the breast fed infant in order to determine the rates of tracer intake and subsequent loss. Deuterium is the tracer of choice for these experiments since it is non-radioactive, and therefore suitable for use in these vulnerable subject groups, and also because of its relative cheapness. Conventionally isotope ratio mass spectrometry (IRMS) has been used for the determination of the amount of deuterium in the body fluids. However this methodology is expensive (an instrument might typically cost US$ 150,000), and it requires a considerable amount of dedicated technical expertise for its operation. Consequently such instrumentation is not widely available, and this has limited the number and scope of studies using this technique. Recently there have been reports of possible alternative technologies for the determination of deuterium in body water which appear attractive because of the wider general availability of the equipment required. It is the purpose of this report to assess these reported methods for their suitability for breast milk intake measurements

  5. Structural health monitoring of cylindrical bodies under impulsive hydrodynamic loading by distributed FBG strain measurements

    International Nuclear Information System (INIS)

    Fanelli, Pierluigi; Ubertini, Stefano; Biscarini, Chiara; Jannelli, Elio; Ubertini, Filippo

    2017-01-01

    Various mechanical, ocean, aerospace and civil engineering problems involve solid bodies impacting the water surface and often result in complex coupled dynamics, characterized by impulsive loading conditions, high amplitude vibrations and large local deformations. Monitoring in such problems for purposes such as remaining fatigue life estimation and real time damage detection is a technical and scientific challenge of primary concern in this context. Open issues include the need for developing distributed sensing systems able to operate at very high acquisition frequencies, to be utilized to study rapidly varying strain fields, with high resolution and very low noise, while scientific challenges mostly relate to the definition of appropriate signal processing and modeling tools enabling the extraction of useful information from distributed sensing signals. Building on previous work by some of the authors, we propose an enhanced method for real time deformed shape reconstruction using distributed FBG strain measurements in curved bodies subjected to impulsive loading and we establish a new framework for applying this method for structural health monitoring purposes, as the main focus of the work. Experiments are carried out on a cylinder impacting the water at various speeds, proving improved performance in displacement reconstruction of the enhanced method compared to its previous version. A numerical study is then carried out considering the same physical problem with different delamination damages affecting the body. The potential for detecting, localizing and quantifying this damage using the reconstruction algorithm is thoroughly investigated. Overall, the results presented in the paper show the potential of distributed FBG strain measurements for real time structural health monitoring of curved bodies under impulsive hydrodynamic loading, defining damage sensitive features in terms of strain or displacement reconstruction errors at selected locations along

  6. A critical evalution of 24 hours whole-body (skeletal) retention of diphosphonate measurements

    International Nuclear Information System (INIS)

    Fogelman, I.; Bessent, R.G.; Scullion, J.E.; Cuthbert, G.F.

    1982-01-01

    In previous studies we have found that 24 hour whole-body retention (WBR) of diphosphonate is a valuable test for the assessment of skeletal metabolism. However, the reproducibility, accuracy and possible sources of error in WBR measurements have not previously been studied. In 21 paired studies the technique was found to be highly reproducible (r = 0.998, p < 0.0001). The coefficient of variation for whole-body counts on day 1 was 0.1% and on day 2, 1.1%. The net whole-body count of a phantom representing the 24 hour whole-body distribution of tracer was 98% of that of a uniform phantom. Ten subjects, counted twice within a few minutes to study the effect of repositioning showed a mean difference between counts of only 0.8%. For eleven subjects with traumatic fractures it was found that 9 had normal values for WBR, while 2 had minimally elevated results. For twenty patients with renal disease but no apparent skeletal disease a significant correlation between serum creatinine and WBR was found (r = 0.72, p<0.001). However WBR results were always normal when serum creatinine values were <130 μmol/l. It is suggested that WBR measurement is accurate and the technique is highly reproducible. The presence of a focal lesion is unlikely to affect a WBR result significantly and if serum creatinine is in the normal range then an elevated WBR result can be assumed to reflect increased skeletal metabolism without further concern as to renal function. (Author)

  7. Changes in Oxygen Partial Pressure in the Vitreous Body and Arterial Blood of Rabbits Depending on Oxygen Concentration in Inspired Mixture.

    Science.gov (United States)

    Amkhanitskaya, L I; Nikolaeva, G V; Sokolova, N A

    2015-07-01

    We demonstrated that the vitreous body of one-month-old rabbits becomes a "reservoir" for storage and accumulation of oxygen after exposure to additional oxygenation of the organism (O2 concentrations in inspired gas mixture were 40, 60, 85, and 99%). The higher was O2 concentration in inspired mixture, the higher was oxygen saturation of the blood and vitreous body. O2 concentration of 40% was relatively safe for eye tissues. O2 concentration >60% induced oxygen accumulation in the vitreous body, which can be a provoking factor for the development of oxygen-induced pathologies.

  8. Evaluation of the dose committed as based on direct measurements with the Whole Body Counter

    International Nuclear Information System (INIS)

    Meladani, C.; Castellani, C.M.; Battisti, P.; Tarroni, G.

    1989-01-01

    During normal working activities or in accidental situations, when the introduction of radioactive gamma emitters is non-negligible amount, accurate determination of effective committed dose equivalent based on direct measurements of the internal contamination cannot be avoided. Internal contamination measurements carried out by Whole Body Counter and the application of dosimetric and metabolic models as proposed by ICRP Publication 30 allow the intakes and committed dose equivalents to be evaluated. This paper presents the evaluation methodologies of committed dose equivalent both for istantaneous and extended contaminations. Furthermore, some advice about useful, opportune modes and time uncertainties due to the application of generalized models to particular situations, are also reported. On the basis of the Chernobyl experience, the general criteria for the chice and size of homogeneous groups of individuals to be measured, are finally submitted with a view to collecting the necessary radiation protection information concerning contamination of a part or a whole population

  9. Telemetric measurement of body core temperature in exercising unconditioned Labrador retrievers.

    Science.gov (United States)

    Angle, T Craig; Gillette, Robert L

    2011-04-01

    This project evaluated the use of an ingestible temperature sensor to measure body core temperature (Tc) in exercising dogs. Twenty-five healthy, unconditioned Labrador retrievers participated in an outdoor 3.5-km run, completed in 20 min on a level, 400-m grass track. Core temperature was measured continuously with a telemetric monitoring system before, during, and after the run. Data were successfully collected with no missing data points during the exercise. Core temperature elevated in the dogs from 38.7 ± 0.3°C at pre-exercise to 40.4 ± 0.6°C post-exercise. While rectal temperatures are still the standard of measurement, telemetric core temperature monitors may offer an easier and more comfortable means of sampling core temperature with minimal human and mechanical interference with the exercising dog.

  10. Assessment of body fat in the pony: part II. Validation of the deuterium oxide dilution technique for the measurement of body fat.

    Science.gov (United States)

    Dugdale, A H A; Curtis, G C; Milne, E; Harris, P A; Argo, C Mc

    2011-09-01

    Excessive accumulations or depletions of body fat have been associated with increased morbidity and mortality in horses and ponies. An objective, minimally-invasive method to accurately quantify body fat in living animals is required to aid nutritional management and define welfare/performance limits. To compare deuterium oxide (D(2) O) dilution-derived estimates of total body water (TBW) and body fat with values obtained by 'gold standard' proximate analysis and cadaver dissection. D(2) O dilution offers a valid method for the determination of TBW and body fat in equids. Seven mature (mean ± s.e. 13 ± 3 years, 212 ± 14 kg, body condition scores 1.25-7/9), healthy, Welsh Mountain pony mares, destined for euthanasia (for nonresearch purposes) were used. Blood samples were collected before and 4 h after D(2) O (0.11-0.13 g/kg bwt, 99.8 atom percent excess) administration. Plasma was analysed by gas isotope ratio mass spectrometry following filtration and zinc reduction. After euthanasia, white adipose tissue (WAT) mass was recorded before all body tissues were analysed by proximate chemical analyses. D(2) O-derived estimates of TBW and body fat were strongly associated with proximate analysis- and dissection-derived values (all r(2) >0.97, P≤0.0001). Bland-Altman analyses demonstrated good agreements between methods. D(2) O dilution slightly overestimated TBW (0.79%, limits of agreement (LoA) -3.75-2.17%) and underestimated total body lipid (1.78%, LoA -0.59-4.15%) and dissected WAT (0.72%, LoA -2.77-4.21%). This study provides the first validation of the D(2) O dilution method for the minimally-invasive, accurate, repeatable and objective measurement of body water and fat in living equids. © 2011 EVJ Ltd.

  11. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  12. Body measurements and carcass traits of castrated and non-castrated Mediterranean buffalos

    Directory of Open Access Journals (Sweden)

    Renata de Oliveira Santos Ramalho

    2013-01-01

    Full Text Available In this study was evaluated the effect of sex condition on body measurements and carcass traits as well as the correlations between them, using data of 20 Mediterranean, from Fazenda Três Rios, at Casimiro de Abreu, Rio de Janeiro, managed in tangola grass pasture, receiving mineral salt ad libitum, slaughtered at approximately 462,05 kg (±28.34. The body measurements were: thoracic depth (TD, croup length (CL, withers height (WH, rump width (RW, rump height (RH, ischium distance (ID, cushion thickness (CT, thoracic perimeter (TP, and dorsal line length (DLL. Data were submited to variance analysis and Pearson correlation. The castrated animals presented higher height of croup. Non-castrated animals had bigger yield from leather than the castrated animals, which influenced the lowest yield of carcass regarding the castrated ones. There was no difference for yield of paws, innards and head in function of the sexual condition. There was significant correlation between the slaughter weight (SW and the following corporal measures: TP, TD, RW, ID and WH.

  13. Identification of Capacitive MEMS Accelerometer Structure Parameters for Human Body Dynamics Measurements

    Directory of Open Access Journals (Sweden)

    Vincas Benevicius

    2013-08-01

    Full Text Available Due to their small size, low weight, low cost and low energy consumption, MEMS accelerometers have achieved great commercial success in recent decades. The aim of this research work is to identify a MEMS accelerometer structure for human body dynamics measurements. Photogrammetry was used in order to measure possible maximum accelerations of human body parts and the bandwidth of the digital acceleration signal. As the primary structure the capacitive accelerometer configuration is chosen in such a way that sensing part measures on all three axes as it is 3D accelerometer and sensitivity on each axis is equal. Hill climbing optimization was used to find the structure parameters. Proof-mass displacements were simulated for all the acceleration range that was given by the optimization problem constraints. The final model was constructed in Comsol Multiphysics. Eigenfrequencies were calculated and model’s response was found, when vibration stand displacement data was fed into the model as the base excitation law. Model output comparison with experimental data was conducted for all excitation frequencies used during the experiments.

  14. 3D Body Scanning Measurement System Associated with RF Imaging, Zero-padding and Parallel Processing

    Directory of Open Access Journals (Sweden)

    Kim Hyung Tae

    2016-04-01

    Full Text Available This work presents a novel signal processing method for high-speed 3D body measurements using millimeter waves with a general processing unit (GPU and zero-padding fast Fourier transform (ZPFFT. The proposed measurement system consists of a radio-frequency (RF antenna array for a penetrable measurement, a high-speed analog-to-digital converter (ADC for significant data acquisition, and a general processing unit for fast signal processing. The RF waves of the transmitter and the receiver are converted to real and imaginary signals that are sampled by a high-speed ADC and synchronized with the kinematic positions of the scanner. Because the distance between the surface and the antenna is related to the peak frequency of the conjugate signals, a fast Fourier transform (FFT is applied to the signal processing after the sampling. The sampling time is finite owing to a short scanning time, and the physical resolution needs to be increased; further, zero-padding is applied to interpolate the spectra of the sampled signals to consider a 1/m floating point frequency. The GPU and parallel algorithm are applied to accelerate the speed of the ZPFFT because of the large number of additional mathematical operations of the ZPFFT. 3D body images are finally obtained by spectrograms that are the arrangement of the ZPFFT in a 3D space.

  15. A new formula for estimation of standard liver volume using computed tomography-measured body thickness.

    Science.gov (United States)

    Ma, Ka Wing; Chok, Kenneth S H; Chan, Albert C Y; Tam, Henry S C; Dai, Wing Chiu; Cheung, Tan To; Fung, James Y Y; Lo, Chung Mau

    2017-09-01

    The objective of this article is to derive a more accurate and easy-to-use formula for finding estimated standard liver volume (ESLV) using novel computed tomography (CT) measurement parameters. New formulas for ESLV have been emerging that aim to improve the accuracy of estimation. However, many of these formulas contain body surface area measurements and logarithms in the equations that lead to a more complicated calculation. In addition, substantial errors in ESLV using these old formulas have been shown. An improved version of the formula for ESLV is needed. This is a retrospective cohort of consecutive living donor liver transplantations from 2005 to 2016. Donors were randomly assigned to either the formula derivation or validation groups. Total liver volume (TLV) measured by CT was used as the reference for a linear regression analysis against various patient factors. The derived formula was compared with the existing formulas. There were 722 patients (197 from the derivation group, 164 from the validation group, and 361 from the recipient group) involved in the study. The donor's body weight (odds ratio [OR], 10.42; 95% confidence interval [CI], 7.25-13.60; P Liver Transplantation 23 1113-1122 2017 AASLD. © 2017 by the American Association for the Study of Liver Diseases.

  16. Classification of obesity by means of the body mass index and verification by measurement of the body composition using the tritium dilution technique

    International Nuclear Information System (INIS)

    Leonhardt, W.; Fischer, S.; Weck, M.; Hanefeld, M.

    1988-01-01

    65 female and 142 male patients have been classified according to their body mass index (BMI) into the categories underweight (BMI 20 or less), normal weight (BMI over 20 - 25), overweight (BMI over 25 - 30), obesity (BMI over 30 - 40), and morbid obesity (BMI over 40). Body composition was measured in all patients using the tritium dilution method. Total body fat was calculated from the total body water values. Relative fat values increased from 17.1% (women) and 14.5% (men) resp. in underweight to 46.2% (women) and 43.3% (men) in morbid obesity. In all classes of BMI men exhibited higher values of body weight, body height and body water and lower values of absolute and relative fat as compared to women. However, the relative fat and water values, relative to 1 in the normal weight class, were equal for both sexes. The results demonstrate that the BMI is very well suited for the classification of obesity. (author)

  17. Evaluation of nuclear magnetic resonance spectroscopy for determination of deuterium abundance in body fluids: application to measurement of total-body water in human infants

    International Nuclear Information System (INIS)

    Rebouche, C.J.; Pearson, G.A.; Serfass, R.E.; Roth, C.W.; Finley, J.W.

    1987-01-01

    Nuclear magnetic resonance (NMR) spectroscopy was used to quantitate abundance of 2H in body water of human infants. This method provides precise measurement of total-body water without the extensive sample preparation requirements of previously described methods for determination of 2H content in body fluids. 2H2O (1 g/kg body weight) was administered to infants and saliva and urine were collected for up to 5 h. An internal standard was added directly to the fluid specimen and 2H enrichment in water was measured by NMR spectroscopy. Working range of deuterium abundance was 0.04-0.32 atom %. Coefficients of variation for saliva samples at 0.20 atom % 2H was 1.97%. 2H content in urine and saliva water reached a plateau by 4 h after administration, and amounts in the two fluids were virtually identical. Mean total-body water determination for six infants was 58.3 +/- 5.8% of body weight (range 53-66%)

  18. Dynamic monitoring of compliant bodies impacting the water surface through local strain measurements

    Science.gov (United States)

    Panciroli, Riccardo; Biscarini, Chiara; Jannelli, Elio; Ubertini, Filippo; Ubertini, Stefano

    2016-04-01

    The understanding and the experimental characterization of the evolution of impulsive loading is crucial in several fields in structural, mechanical and ocean engineering, naval architecture and aerospace. In this regards, we developed an experimental methodology to reconstruct the deformed shape of compliant bodies subjected to impulsive loadings, as those encountered in water entry events, starting from a finite number of local strain measurements performed through Fiber Bragg Gratings. The paper discusses the potential applications of the proposed methodology for: i) real-time damage detection and structural health monitoring, ii) fatigue assessment and iii) impulsive load estimation.

  19. Ordinance on the body responsible for taking measures in case of increased radioactivity (OROIR)

    International Nuclear Information System (INIS)

    1987-04-01

    This Ordinance, based on atomic energy legislation, public safety, military organisation and the defense council, replaced a previous ordinance of 1966 on alert in case of increased radioactivity. It sets up the body responsible for this work and describes the tasks to be performed in case of an occurrence which could create hazards for the population due to increased radioactivity. If a Swiss nuclear installation creates such a hazard, the 1982 Ordinance on emergency measures in the neighbourhood of nuclear installations also applies. The Ordinance entered into force on 1 May 1987 (NEA) [fr

  20. A new system using NMR technology for measurement of body composition in experimental animals

    International Nuclear Information System (INIS)

    Suzuki, Jun; Nishikibe, Masaru

    2004-01-01

    Measurement of body composition (fat mass) is an important item in pathophysiological and pharmacological studies using small animals (mice) in the fields of obesity and diabetes. The existing methods are, however, difficult, time consuming, and require a shielding facility. Now a novel system using nuclear magnetic resonance (NMR) technique was developed for measurement of body composition in small animals (mice) that provides noninvasive and rapid measurement without anesthetics; we introduced and evaluated this system and tried another application of this system. First, we validated this system using canola oil, soft tissues (adipose and skeletal muscle), and various kinds of rodent chows. Accuracy, precision, and reproducibility of this system were demonstrated to be equal to those in standard chemical methods. A strong positive correlation (y=x) between the results of NMR and chemical methods was found. Secondly, we evaluated accuracy and assay range of the NMR method using live mice that were fasted overnight or fed high fat diet (HFD). In fasted mice, a small but quantitative decrease of fat mass (5.1% from 9.1%) was detected. Total decrease of fat and lean mass (5.0 g) in fasted mice was equivalent to the decrease of body weight (5.0 g). In mice fed the HFD, increase of fat mass with relative decrease of lean mass were qualitatively detected in a time-dependent manner. We would like to emphasize that operation of the system was actually easy and measurements were accomplished in a short time (1 minute). Thirdly, we tried to use the NMR system for determination of hepatic fat contents using mice fasted or treated with a peroxisome proliferator-activated receptor (PPAR)γ agonist; our results showed a quantitative increase in fat by fasting or in decrease in fat by the drug treatment. The changes of fat contents determined by the NMR method were well correlated with the changes in triglyceride and total cholesterol values obtained by the biochemical assays

  1. A psychometric measure of working memory capacity for configured body movement.

    Directory of Open Access Journals (Sweden)

    Ying Choon Wu

    Full Text Available Working memory (WM models have traditionally assumed at least two domain-specific storage systems for verbal and visuo-spatial information. We review data that suggest the existence of an additional slave system devoted to the temporary storage of body movements, and present a novel instrument for its assessment: the movement span task. The movement span task assesses individuals' ability to remember and reproduce meaningless configurations of the body. During the encoding phase of a trial, participants watch short videos of meaningless movements presented in sets varying in size from one to five items. Immediately after encoding, they are prompted to reenact as many items as possible. The movement span task was administered to 90 participants along with standard tests of verbal WM, visuo-spatial WM, and a gesture classification test in which participants judged whether a speaker's gestures were congruent or incongruent with his accompanying speech. Performance on the gesture classification task was not related to standard measures of verbal or visuo-spatial working memory capacity, but was predicted by scores on the movement span task. Results suggest the movement span task can serve as an assessment of individual differences in WM capacity for body-centric information.

  2. Anaphylaxis Imaging: Non-Invasive Measurement of Surface Body Temperature and Physical Activity in Small Animals.

    Directory of Open Access Journals (Sweden)

    Krisztina Manzano-Szalai

    Full Text Available In highly sensitized patients, the encounter with a specific allergen from food, insect stings or medications may rapidly induce systemic anaphylaxis with potentially lethal symptoms. Countless animal models of anaphylaxis, most often in BALB/c mice, were established to understand the pathophysiology and to prove the safety of different treatments. The most common symptoms during anaphylactic shock are drop of body temperature and reduced physical activity. To refine, improve and objectify the currently applied manual monitoring methods, we developed an imaging method for the automated, non-invasive measurement of the whole-body surface temperature and, at the same time, of the horizontal and vertical movement activity of small animals. We tested the anaphylaxis imaging in three in vivo allergy mouse models for i milk allergy, ii peanut allergy and iii egg allergy. These proof-of-principle experiments suggest that the imaging technology represents a reliable non-invasive method for the objective monitoring of small animals during anaphylaxis over time. We propose that the method will be useful for monitoring diseases associated with both, changes in body temperature and in physical behaviour.

  3. Whole Body Computed Tomography with Advanced Imaging Techniques: A Research Tool for Measuring Body Composition in Dogs

    Directory of Open Access Journals (Sweden)

    Dharma Purushothaman

    2013-01-01

    Full Text Available The use of computed tomography (CT to evaluate obesity in canines is limited. Traditional CT image analysis is cumbersome and uses prediction equations that require manual calculations. In order to overcome this, our study investigated the use of advanced image analysis software programs to determine body composition in dogs with an application to canine obesity research. Beagles and greyhounds were chosen for their differences in morphology and propensity to obesity. Whole body CT scans with regular intervals were performed on six beagles and six greyhounds that were subjected to a 28-day weight-gain protocol. The CT images obtained at days 0 and 28 were analyzed using software programs OsiriX, ImageJ, and AutoCAT. The CT scanning technique was able to differentiate bone, lean, and fat tissue in dogs and proved sensitive enough to detect increases in both lean and fat during weight gain over a short period. A significant difference in lean : fat ratio was observed between the two breeds on both days 0 and 28 (P<0.01. Therefore, CT and advanced image analysis proved useful in the current study for the estimation of body composition in dogs and has the potential to be used in canine obesity research.

  4. Is Oral Temperature an Accurate Measurement of Deep Body Temperature? A Systematic Review

    Science.gov (United States)

    Mazerolle, Stephanie M.; Ganio, Matthew S.; Casa, Douglas J.; Vingren, Jakob; Klau, Jennifer

    2011-01-01

    Context: Oral temperature might not be a valid method to assess core body temperature. However, many clinicians, including athletic trainers, use it rather than criterion standard methods, such as rectal thermometry. Objective: To critically evaluate original research addressing the validity of using oral temperature as a measurement of core body temperature during periods of rest and changing core temperature. Data Sources: In July 2010, we searched the electronic databases PubMed, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINAHL), SPORTDiscus, Academic Search Premier, and the Cochrane Library for the following concepts: core body temperature, oral, and thermometers. Controlled vocabulary was used, when available, as well as key words and variations of those key words. The search was limited to articles focusing on temperature readings and studies involving human participants. Data Synthesis: Original research was reviewed using the Physiotherapy Evidence Database (PEDro). Sixteen studies met the inclusion criteria and subsequently were evaluated by 2 independent reviewers. All 16 were included in the review because they met the minimal PEDro score of 4 points (of 10 possible points), with all but 2 scoring 5 points. A critical review of these studies indicated a disparity between oral and criterion standard temperature methods (eg, rectal and esophageal) specifically as the temperature increased. The difference was −0.50°C ± 0.31°C at rest and −0.58°C ± 0.75°C during a nonsteady state. Conclusions: Evidence suggests that, regardless of whether the assessment is recorded at rest or during periods of changing core temperature, oral temperature is an unsuitable diagnostic tool for determining body temperature because many measures demonstrated differences greater than the predetermined validity threshold of 0.27°C (0.5°F). In addition, the differences were greatest at the highest rectal temperatures. Oral temperature cannot

  5. The choice of label and measurement technique in tracer studies of body protein metabolism in man

    International Nuclear Information System (INIS)

    James, W.P.T.; Sender, P.M.; Garlick, P.J.; Waterlow, J.C.

    1975-01-01

    The turnover of non-serum proteins in man has had limited study despite the physiological importance of maintaining the balance between synthesis and breakdown of body proteins. Body protein is usually considered as a single pool and breakdown rates are often measured by monitoring excreted label at intervals after pulse labelling with radioactive or 15 N amino acids. No label has yet been used for measuring tissue protein breakdown in man which is free from the major problem of label re-utilization. All measurements of breakdown rates, eg. with 75 Se-selenomethionine, 15 N- or 14 C-glycine, give rate constants which are too low. The heterogeneity of body proteins also means that an estimate of the weighted average breakdown rate can only be obtained after following the excretion of isotope for a long period, perhaps of the order of 3-4 half-lives which, for man, would be 100 days after labelling. We therefore use infusions with either 14 C- or 15 N-labelled amino acids to measure breakdown and synthesis rates: these values are less affected by problems of protein heterogeneity. Single injection techniques are subject to more error than constant infusions of label because of the difficulty of defining the precursor activity. 15 N labelling need not be confined to essential amino acids if total protein rather than amino acid turnover is studied: the latter involves measurements of the labelled amino acid itself which is difficult with 15 N because of the small amounts of free amino acid nitrogen available. Carbon labelling of non-essential amino acids is unsuitable for studies of protein turnover and the choice of the position of the label on the molecule is important when labelled essential amino acids are employed. Short-term changes in protein metabolism are evaluated better with amino acids with a small pool size; the equilibration time in the excretory bicarbonate pool is also shorter than in the urea pool so that 15 N is less useful than carbon labelling. We

  6. 3D Measurement of Forearm and Upper Arm during Throwing Motion using Body Mounted Sensor

    Science.gov (United States)

    Koda, Hideharu; Sagawa, Koichi; Kuroshima, Kouta; Tsukamoto, Toshiaki; Urita, Kazutaka; Ishibashi, Yasuyuki

    The aim of this study is to propose the measurement method of three-dimensional (3D) movement of forearm and upper arm during pitching motion of baseball using inertial sensors without serious consideration of sensor installation. Although high accuracy measurement of sports motion is achieved by using optical motion capture system at present, it has some disadvantages such as the calibration of cameras and limitation of measurement place. Whereas the proposed method for 3D measurement of pitching motion using body mounted sensors provides trajectory and orientation of upper arm by the integration of acceleration and angular velocity measured on upper limb. The trajectory of forearm is derived so that the elbow joint axis of forearm corresponds to that of upper arm. Spatial relation between upper limb and sensor system is obtained by performing predetermined movements of upper limb and utilizing angular velocity and gravitational acceleration. The integration error is modified so that the estimated final position, velocity and posture of upper limb agree with the actual ones. The experimental results of the measurement of pitching motion show that trajectories of shoulder, elbow and wrist estimated by the proposed method are highly correlated to those from the motion capture system within the estimation error of about 10 [%].

  7. Measurement of body temperature in normothermic and febrile rats: Limitations of using rectal thermometry.

    Science.gov (United States)

    Dangarembizi, Rachael; Erlwanger, Kennedy H; Mitchell, Duncan; Hetem, Robyn S; Madziva, Michael T; Harden, Lois M

    2017-10-01

    Stress-induced hyperthermia following rectal thermometry is reported in normothermic rats, but appears to be muted or even absent in febrile rats. We therefore investigated whether the use of rectal thermometry affects the accuracy of temperature responses recorded in normothermic and febrile rats. Using intra-abdominally implanted temperature-sensitive radiotelemeters we measured the temperature response to rectal temperature measurement in male Sprague Dawley rats (~200g) injected subcutaneously with Brewer's yeast (20ml/kg of a 20% Brewer's yeast solution=4000mg/kg) or saline (20ml/kg of 0.9% saline). Rats had been pre-exposed to, or were naive to rectal temperature measurement before the injection. The first rectal temperature measurement was taken in the plateau phase of the fever (18h after injection) and at hourly intervals thereafter. In normothermic rats, rectal temperature measurement was associated with an increase in abdominal temperature (0.66±0.27°C) that had a rapid onset (5-10min), peaked at 15-20min and lasted for 35-50min. The hyperthermic response to rectal temperature measurement was absent in febrile rats. Exposure to rectal temperature measurement on two previous occasions did not reduce the hyperthermia. There was a significant positive linear association between temperatures recorded using the two methods, but the agreement interval identified that rectal temperature measured with a thermocouple probe could either be 0.7°C greater or 0.5°C lower than abdominal temperature measured with radiotelemeter. Thus, due to stress-induced hyperthermia, rectal thermometry does not ensure accurate recording of body temperature in short-spaced, intermittent intervals in normothermic and febrile rats. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. The influence of N-acetylcysteine on the measurement of prothrombin time and activated partial thromboplastin time in healthy subjects

    DEFF Research Database (Denmark)

    Jepsen, S; Hansen, A B

    1994-01-01

    mg kg-1 h-1 for 32 h in six male subjects. The intrinsic, extrinsic and common pathway of coagulation were monitored with activated partial thromboplastin time (APTT), and prothrombin time, respectively. In addition, the extrinsic coagulation pathway was monitored with the clotting activity of single...... factors II, VII, and X. No effect on the intrinsic coagulation pathway was observed. There was a significant and rapid decrease in prothrombin time. Coagulation factors II, VII and X, the three components of prothrombin time, decreased significantly to different degrees. We conclude that infusion of N...

  9. Measurement of absorbed radiation doses during whole body irradiation for bone marrow transplants using thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Giordani, Adelmo Jose; Segreto, Helena Cristina Comodo; Segreto, Roberto Araujo; Medeiros, Regina Bitelli; Oliveira, Jose Salvador R. de

    2004-01-01

    The objective was to evaluate the precision of the absorbed radiation doses in bone marrow transplant therapy during whole body irradiation. Two-hundred CaSO 4 :Dy + teflon tablets were calibrated in air and in 'phantom'. These tablets were randomly selected and divided in groups of five in the patients' body. The dosimetric readings were obtained using a Harshaw 4000A reader. Nine patients had their entire bodies irradiated in parallel and opposite laterals in a cobalt-60 Alcion II model, with a dose rate of 0.80 Gy/min at 80.5 cm, {(10 ? 10) cm 2 field. The dosimetry of this unit was performed using a Victoreen 500 dosimeter. For the determination of the mean dose at each point evaluated, the individual values of the tablets calibrated in air or 'phantom' were used, resulting in a build up of 2 mm to superficialize the dose at a distance of 300 cm. In 70% of the patients a variation of less than 5% in the dose was obtained. In 30% of the patients this variation was less than 10%, when values obtained were compared to the values calculated at each point. A mean absorption of 14% was seen in the head, and an increase of 2% of the administered dose was seen in the lungs. In patients with latero-lateral distance greater than 35 cm the variation between the calculated doses and the measured doses reached 30% of the desired dose, without the use of compensation filters. The measured values of the absorbed doses at the various anatomic points compared to the desired doses (theoretic) presented a tolerance of ± 10%, considering the existent anatomical differences and when using the individual calibration factors of the tablets. (author)

  10. Association of objectively measured physical activity with body components in European adolescents.

    Science.gov (United States)

    Jiménez-Pavón, David; Fernández-Vázquez, Amaya; Alexy, Ute; Pedrero, Raquel; Cuenca-García, Magdalena; Polito, Angela; Vanhelst, Jérémy; Manios, Yannis; Kafatos, Anthony; Molnar, Dénes; Sjöström, Michael; Moreno, Luis A

    2013-07-18

    Physical activity (PA) is suggested to contribute to fat loss not only through increasing energy expenditure "per se" but also increasing muscle mass; therefore, it would be interesting to better understand the specific associations of PA with the different body's components such as fat mass and muscle mass. The aim of the present study was to examine the association between objectively measured PA and indices of fat mass and muscle components independently of each other giving, at the same time, gender-specific information in a wide cohort of European adolescents. A cross-sectional study in a school setting was conducted in 2200 (1016 males) adolescents (14.7 ± 1.2 years). Weight, height, skinfold thickness, bioimpedance and PA (accelerometry) were measured. Indices of fat mass (body mass index, % fat mass, sum of skinfolds) and muscular component (assessed as fat-free mass) were calculated. Multiple regression analyses were performed adjusting for several confounders including fat-free mass and fat mass when possible. Vigorous PA was positively associated with height (pgenders, except for average PA in relation with body mass index in females. Regarding muscular components, vigorous PA showed positive associations with fat-free mass and muscle mass (all pgenders. Average PA was positively associated with fat-free mass (both p<0.05) in males and females. The present study suggests that PA, especially vigorous PA, is negatively associated with indices of fat mass and positively associated with markers of muscle mass, after adjusting for several confounders (including indices of fat mass and muscle mass when possible). Future studies should focus not only on the classical relationship between PA and fat mass, but also on PA and muscular components, analyzing the independent role of both with the different PA intensities.

  11. Accuracy of 24-h whole-body (skeletal) retention of diphosphonate measurements

    International Nuclear Information System (INIS)

    Fogelman, I.; Scullion, J.E.; Bessent, R.; Cuthbert, G.F.

    1982-01-01

    The 24-h whole-body retention (WBR) of diphosphonate was a valuable test for the assessment of skeletal metabolism. However, the reproducibility, accuracy and possible sources of error in WBR measurements have not previously been studied. In 21 paired studies the technique was found to be highly reproducible (r=0.998, R<0.0001). The coefficient of variation for whole-body counts on day 1 was 0.1% and on day 2, 1.1%. A phantom was used to assess the possible error introduced by redistribution of tracer. The net whole-body count of the phantom representing the 24-h distribution was 98% of that of a uniform phantom. Ten subjects were counted twice within a few minutes to study the effect of repositioning, and showed a mean difference between counts of only 0.8%. Eleven subjects with traumatic fractures were studied to assess the possible contribution of focal lesions to WBR. It was found that nine subjects had normal values for WBR, while two had minimally elevated results. Twenty patients with renal disease but no apparent skeletal disease were also studied to assess the possible contribution of soft-tissue retention to WBR. A significant correlation between serum creatinine and WBR was found (r=0.72, P<0.001). However WBR results were always normal when serum creatinine values were <130 μmol/1. It is suggested that WBR measurement is accurate and the technique is hgihly reproducible. The presence of a focal lesion is unlikely to affect a WBR result significantly and if serum creatinine is the normal range then WBR can be assumed to reflect skeletal metabolism without further concern as to renal function. (orig.)

  12. Force sensing using 3D displacement measurements in linear elastic bodies

    Science.gov (United States)

    Feng, Xinzeng; Hui, Chung-Yuen

    2016-07-01

    In cell traction microscopy, the mechanical forces exerted by a cell on its environment is usually determined from experimentally measured displacement by solving an inverse problem in elasticity. In this paper, an innovative numerical method is proposed which finds the "optimal" traction to the inverse problem. When sufficient regularization is applied, we demonstrate that the proposed method significantly improves the widely used approach using Green's functions. Motivated by real cell experiments, the equilibrium condition of a slowly migrating cell is imposed as a set of equality constraints on the unknown traction. Our validation benchmarks demonstrate that the numeric solution to the constrained inverse problem well recovers the actual traction when the optimal regularization parameter is used. The proposed method can thus be applied to study general force sensing problems, which utilize displacement measurements to sense inaccessible forces in linear elastic bodies with a priori constraints.

  13. Phased Acoustic Array Measurements of a 5.75 Percent Hybrid Wing Body Aircraft

    Science.gov (United States)

    Burnside, Nathan J.; Horne, William C.; Elmer, Kevin R.; Cheng, Rui; Brusniak, Leon

    2016-01-01

    Detailed acoustic measurements of the noise from the leading-edge Krueger flap of a 5.75 percent Hybrid Wing Body (HWB) aircraft model were recently acquired with a traversing phased microphone array in the AEDC NFAC (Arnold Engineering Development Complex, National Full Scale Aerodynamics Complex) 40- by 80-Foot Wind Tunnel at NASA Ames Research Center. The spatial resolution of the array was sufficient to distinguish between individual support brackets over the full-scale frequency range of 100 to 2875 Hertz. For conditions representative of landing and take-off configuration, the noise from the brackets dominated other sources near the leading edge. Inclusion of flight-like brackets for select conditions highlights the importance of including the correct number of leading-edge high-lift device brackets with sufficient scale and fidelity. These measurements will support the development of new predictive models.

  14. Automatic and strategic measures as predictors of mirror gazing among individuals with body dysmorphic disorder symptoms.

    Science.gov (United States)

    Clerkin, Elise M; Teachman, Bethany A

    2009-08-01

    The current study tests cognitive-behavioral models of body dysmorphic disorder (BDD) by examining the relationship between cognitive biases and correlates of mirror gazing. To provide a more comprehensive picture, we investigated both relatively strategic (i.e., available for conscious introspection) and automatic (i.e., outside conscious control) measures of cognitive biases in a sample with either high (n = 32) or low (n = 31) BDD symptoms. Specifically, we examined the extent that (1) explicit interpretations tied to appearance, as well as (2) automatic associations and (3) strategic evaluations of the importance of attractiveness predict anxiety and avoidance associated with mirror gazing. Results indicated that interpretations tied to appearance uniquely predicted self-reported desire to avoid, whereas strategic evaluations of appearance uniquely predicted peak anxiety associated with mirror gazing, and automatic appearance associations uniquely predicted behavioral avoidance. These results offer considerable support for cognitive models of BDD, and suggest a dissociation between automatic and strategic measures.

  15. Automatic and Strategic Measures as Predictors of Mirror Gazing Among Individuals with Body Dysmorphic Disorder Symptoms

    Science.gov (United States)

    Clerkin, Elise M.; Teachman, Bethany A.

    2011-01-01

    The current study tests cognitive-behavioral models of body dysmorphic disorder (BDD) by examining the relationship between cognitive biases and correlates of mirror gazing. To provide a more comprehensive picture, we investigated both relatively strategic (i.e., available for conscious introspection) and automatic (i.e., outside conscious control) measures of cognitive biases in a sample with either high (n=32) or low (n=31) BDD symptoms. Specifically, we examined the extent that 1) explicit interpretations tied to appearance, as well as 2) automatic associations and 3) strategic evaluations of the importance of attractiveness predict anxiety and avoidance associated with mirror gazing. Results indicated that interpretations tied to appearance uniquely predicted self-reported desire to avoid, while strategic evaluations of appearance uniquely predicted peak anxiety associated with mirror gazing, and automatic appearance associations uniquely predicted behavioral avoidance. These results offer considerable support for cognitive models of BDD, and suggest a dissociation between automatic and strategic measures. PMID:19684496

  16. Live weight and body measurements of male and female native ducks raised in different raising systems

    Directory of Open Access Journals (Sweden)

    Kadir Önk

    2018-05-01

    Full Text Available ABSTRACT The purpose of this study was to determine live weight and body measurements of male and female native ducks raised in different raising systems. One hundred and twenty native ducks (60 males, 60 females were used in the study. The ducks were raised in deep litter floor and cage systems. Live weight and body values were measured every two weeks, until they were 56 days old. Three-parameter logistic regression and Gompertz model were used to determine growth model of male and female ducks. Interactions of time-raising system and time-sex were statistically significant in terms of live weight. At the end of eight weeks, live weights of ducks raised in deep litter floor were higher than ducks raised in cage system. In addition, live weights of male ducks were higher than female ducks. Consequently, deep litter floor is more appropriate for live weight in native ducks. Accuracy rate of Three-parameter Logistic and Gompertz models for estimation of growth in ducks was between 0.91-0.95 and similar results were obtained from both models. The Gompertz model is appropriate for the data structure of this study because it contains fewer iterations than the Three-Parameter Logistic model.

  17. A wireless pH sensor using magnetoelasticity for measurement of body fluid acidity.

    Science.gov (United States)

    Pang, Pengfei; Gao, Xianjuan; Xiao, Xilin; Yang, Wenyue; Cai, Qingyun; Yao, Shouzhuo

    2007-04-01

    The determination of body fluid acidity using a wireless magnetoelastic pH-sensitive sensor is described. The sensor was fabricated by casting a layer of pH-sensitive polymer on a magnetoelastic ribbon. In response to an externally applied time-varying magnetic field, the magnetoelastic sensor mechanically vibrates at a characteristic frequency that is inversely dependent upon the mass of the pH polymer film, which varies as the film swells and shrinks in response to pH. As the magnetoelastic sensor is magnetostrictive, the mechanical vibrations of the sensor launch magnetic flux that can be detected remotely using a pickup coil. The sensor can be used for direct measurements of body fluid acidity without a pretreatment of the sample by using a filtration membrane. A reversible and linear response was obtained between pH 5.0 and 8.0 with a measurement resolution of pH 0.1 and a slope of 0.2 kHz pH(-1). Since there are no physical connections between the sensor and the instrument, the sensor can be applied to in vivo and in situ monitoring of the physiological pH and its fluctuations.

  18. Wake Measurement Downstream of a Hybrid Wing Body Model with Blown Flaps

    Science.gov (United States)

    Lin, John C.; Jones, Gregory S.; Allan, Brian G.; Westra, Bryan W.; Collins, Scott W.; Zeune, Cale H.

    2010-01-01

    Flow-field measurements were obtained in the wake of a full-span Hybrid Wing Body model with internally blown flaps. The test was performed at the NASA Langley 14 x 22 Foot Subsonic Tunnel at low speeds. Off-body measurements were obtained with a 7-hole probe rake survey system. Three model configurations were investigated. At 0deg angle of attack the surveys were completed with 0deg and 60deg flap deflections. At 10deg angle of attack the wake surveys were completed with a slat and a 60deg flap deflection. The 7-hole probe results further quantified two known swirling regions (downstream of the outboard flap edge and the inboard/outboard flap juncture) for the 60deg flap cases with blowing. Flowfield results and the general trends are very similar for the two blowing cases at nozzle pressure ratios of 1.37 and 1.56. High downwash velocities correlated with the enhanced lift for the 60deg flap cases with blowing. Jet-induced effects are the largest at the most inboard station for all (three) velocity components due in part to the larger inboard slot height. The experimental data are being used to improve computational tools for high-lift wings with integrated powered-lift technologies.

  19. Do digestive contents confound body mass as a measure of relative condition in nestling songbirds?

    Science.gov (United States)

    Streby, Henry M.; Peterson, Sean M.; Lehman, Justin A.; Kramer, Gunnar R.; Vernasco, Ben J.; Andersen, David E.

    2014-01-01

    Relative nestling condition, typically measured as nestling mass or as an index including nestling mass, is commonly purported to correlate with fledgling songbird survival. However, most studies directly investigating fledgling survival have found no such relationship. We weighed feces and stomach contents of nestling golden-winged warblers (Vermivora chrysoptera) to investigate the potential contribution of variation in digestive contents to differences in nestling mass. We estimated that the mass of a seventh-day (near fledging) nestling golden-winged warbler varies by 0.65 g (approx. 9% of mean nestling mass) depending on the contents of the nestling's digestive system at the time of weighing, and that digestive contents are dissimilar among nestlings at any moment the brood is removed from the nest for weighing. Our conservative estimate of within-individual variation in digestive contents equals 72% and 24% of the mean within-brood and population-wide range in nestling mass, respectively. Based on our results, a substantive but typically unknown amount of the variation in body mass among nestlings is confounded by differences in digestive contents. We conclude that short-term variation in digestive contents likely precludes the use of body mass, and therefore any mass-dependent index, as a measure of relative nestling condition or as a predictor of survival in golden-winged warblers and likely in many other songbirds of similar size.

  20. Theoretical and Experimental Studies of Epidermal Heat Flux Sensors for Measurements of Core Body Temperature

    Science.gov (United States)

    Zhang, Yihui; Webb, Richard Chad; Luo, Hongying; Xue, Yeguang; Kurniawan, Jonas; Cho, Nam Heon; Krishnan, Siddharth; Li, Yuhang; Huang, Yonggang

    2016-01-01

    Long-term, continuous measurement of core body temperature is of high interest, due to the widespread use of this parameter as a key biomedical signal for clinical judgment and patient management. Traditional approaches rely on devices or instruments in rigid and planar forms, not readily amenable to intimate or conformable integration with soft, curvilinear, time-dynamic, surfaces of the skin. Here, materials and mechanics designs for differential temperature sensors are presented which can attach softly and reversibly onto the skin surface, and also sustain high levels of deformation (e.g., bending, twisting, and stretching). A theoretical approach, together with a modeling algorithm, yields core body temperature from multiple differential measurements from temperature sensors separated by different effective distances from the skin. The sensitivity, accuracy, and response time are analyzed by finite element analyses (FEA) to provide guidelines for relationships between sensor design and performance. Four sets of experiments on multiple devices with different dimensions and under different convection conditions illustrate the key features of the technology and the analysis approach. Finally, results indicate that thermally insulating materials with cellular structures offer advantages in reducing the response time and increasing the accuracy, while improving the mechanics and breathability. PMID:25953120

  1. Standardization of a Volumetric Displacement Measurement for Two-Body Abrasion Scratch Test Data Analysis

    Science.gov (United States)

    Street, K. W. Jr.; Kobrick, R. L.; Klaus, D. M.

    2011-01-01

    A limitation has been identified in the existing test standards used for making controlled, two-body abrasion scratch measurements based solely on the width of the resultant score on the surface of the material. A new, more robust method is proposed for analyzing a surface scratch that takes into account the full three-dimensional profile of the displaced material. To accomplish this, a set of four volume- displacement metrics was systematically defined by normalizing the overall surface profile to denote statistically the area of relevance, termed the Zone of Interaction. From this baseline, depth of the trough and height of the plowed material are factored into the overall deformation assessment. Proof-of-concept data were collected and analyzed to demonstrate the performance of this proposed methodology. This technique takes advantage of advanced imaging capabilities that allow resolution of the scratched surface to be quantified in greater detail than was previously achievable. When reviewing existing data analysis techniques for conducting two-body abrasive scratch tests, it was found that the ASTM International Standard G 171 specified a generic metric based only on visually determined scratch width as a way to compare abraded materials. A limitation to this method was identified in that the scratch width is based on optical surface measurements, manually defined by approximating the boundaries, but does not consider the three-dimensional volume of material that was displaced. With large, potentially irregular deformations occurring on softer materials, it becomes unclear where to systematically determine the scratch width. Specifically, surface scratches on different samples may look the same from a top view, resulting in an identical scratch width measurement, but may vary in actual penetration depth and/or plowing deformation. Therefore, two different scratch profiles would be measured as having identical abrasion properties, although they differ

  2. Severity of Carpal Tunnel Syndrome and Diagnostic Accuracy of Hand and Body Anthropometric Measures

    Science.gov (United States)

    Mondelli, Mauro; Farioli, Andrea; Mattioli, Stefano; Aretini, Alessandro; Ginanneschi, Federica; Greco, Giuseppe; Curti, Stefania

    2016-01-01

    Objective To study the diagnostic properties of hand/wrist and body measures according to validated clinical and electrophysiological carpal tunnel syndrome (CTS) severity scales. Methods We performed a prospective case-control study. For each case, two controls were enrolled. Two five-stage clinical and electrophysiological scales were used to evaluate CTS severity. Anthropometric measurements were collected and obesity indicators and hand/wrist ratios were calculated. Area under the receiver operating characteristic curves (AUC), sensitivity, specificity, and likelihood ratios were calculated separately by gender. Results We consecutively enrolled 370 cases and 747 controls. The wrist-palm ratio, waist-hip-height ratio and waist-stature ratio showed the highest proportion of cases with abnormal values in the severe stages of CTS for clinical and electrophysiological severity scales in both genders. Accuracy tended to increase with CTS severity for females and males. In severe stage, most of the indexes presented moderate accuracy in both genders. Among subjects with severe CTS, the wrist-palm ratio presented the highest AUC for hand measures in the clinical and electrophysiological severity scales both in females (AUC 0.83 and 0.76, respectively) and males (AUC 0.91 and 0.82, respectively). Among subjects with severe CTS, the waist-stature ratio showed the highest AUC for body measures in the clinical and electrophysiological severity scales both in females (AUC 0.78 and 0.77, respectively) and males (AUC 0.84 and 0.76, respectively). The results of waist-hip-height ratio AUC were similar. Conclusions Wrist-palm ratio, waist-hip-height ratio and waist-stature ratio could contribute to support the diagnostic hypothesis of severe CTS that however has to be confirmed by nerve conduction study. PMID:27768728

  3. Severity of Carpal Tunnel Syndrome and Diagnostic Accuracy of Hand and Body Anthropometric Measures.

    Directory of Open Access Journals (Sweden)

    Mauro Mondelli

    Full Text Available To study the diagnostic properties of hand/wrist and body measures according to validated clinical and electrophysiological carpal tunnel syndrome (CTS severity scales.We performed a prospective case-control study. For each case, two controls were enrolled. Two five-stage clinical and electrophysiological scales were used to evaluate CTS severity. Anthropometric measurements were collected and obesity indicators and hand/wrist ratios were calculated. Area under the receiver operating characteristic curves (AUC, sensitivity, specificity, and likelihood ratios were calculated separately by gender.We consecutively enrolled 370 cases and 747 controls. The wrist-palm ratio, waist-hip-height ratio and waist-stature ratio showed the highest proportion of cases with abnormal values in the severe stages of CTS for clinical and electrophysiological severity scales in both genders. Accuracy tended to increase with CTS severity for females and males. In severe stage, most of the indexes presented moderate accuracy in both genders. Among subjects with severe CTS, the wrist-palm ratio presented the highest AUC for hand measures in the clinical and electrophysiological severity scales both in females (AUC 0.83 and 0.76, respectively and males (AUC 0.91 and 0.82, respectively. Among subjects with severe CTS, the waist-stature ratio showed the highest AUC for body measures in the clinical and electrophysiological severity scales both in females (AUC 0.78 and 0.77, respectively and males (AUC 0.84 and 0.76, respectively. The results of waist-hip-height ratio AUC were similar.Wrist-palm ratio, waist-hip-height ratio and waist-stature ratio could contribute to support the diagnostic hypothesis of severe CTS that however has to be confirmed by nerve conduction study.

  4. Re-visiting the tympanic membrane vicinity as core body temperature measurement site.

    Directory of Open Access Journals (Sweden)

    Wui Keat Yeoh

    Full Text Available Core body temperature (CBT is an important and commonly used indicator of human health and endurance performance. A rise in baseline CBT can be attributed to an onset of flu, infection or even thermoregulatory failure when it becomes excessive. Sites which have been used for measurement of CBT include the pulmonary artery, the esophagus, the rectum and the tympanic membrane. Among them, the tympanic membrane is an attractive measurement site for CBT due to its unobtrusive nature and ease of measurement facilitated, especially when continuous CBT measurements are needed for monitoring such as during military, occupational and sporting settings. However, to-date, there are still polarizing views on the suitability of tympanic membrane as a CBT site. This paper will revisit a number of key unresolved issues in the literature and also presents, for the first time, a benchmark of the middle ear temperature against temperature measurements from other sites. Results from experiments carried out on human and primate subjects will be presented to draw a fresh set of insights against the backdrop of hypotheses and controversies.

  5. Evaluation of body condition score measured throughout lactation as an indicator of fertility in dairy cattle.

    Science.gov (United States)

    Banos, G; Brotherstone, S; Coffey, M P

    2004-08-01

    Body condition score (BCS) records of primiparous Holstein cows were analyzed both as a single measure per animal and as repeated measures per sire of cow. The former resulted in a single, average, genetic evaluation for each sire, and the latter resulted in separate genetic evaluations per day of lactation. Repeated measure analysis yielded genetic correlations of less than unity between days of lactation, suggesting that BCS may not be the same trait across lactation. Differences between daily genetic evaluations on d 10 or 30 and subsequent daily evaluations were used to assess BCS change at different stages of lactation. Genetic evaluations for BCS level or change were used to estimate genetic correlations between BCS measures and fertility traits in order to assess the capacity of BCS to predict fertility. Genetic correlation estimates with calving interval and non-return rate were consistently higher for daily BCS than single measure BCS evaluations, but results were not always statistically different. Genetic correlations between BCS change and fertility traits were not significantly different from zero. The product of the accuracy of BCS evaluations with their genetic correlation with the UK fertility index, comprising calving interval and non-return rate, was consistently higher for daily than for single BCS evaluations, by 28 to 53%. This product is associated with the conceptual correlated response in fertility from BCS selection and was highest for early (d 10 to 75) evaluations.

  6. Re-visiting the tympanic membrane vicinity as core body temperature measurement site

    Science.gov (United States)

    Gan, Chee Wee; Liang, Wenyu

    2017-01-01

    Core body temperature (CBT) is an important and commonly used indicator of human health and endurance performance. A rise in baseline CBT can be attributed to an onset of flu, infection or even thermoregulatory failure when it becomes excessive. Sites which have been used for measurement of CBT include the pulmonary artery, the esophagus, the rectum and the tympanic membrane. Among them, the tympanic membrane is an attractive measurement site for CBT due to its unobtrusive nature and ease of measurement facilitated, especially when continuous CBT measurements are needed for monitoring such as during military, occupational and sporting settings. However, to-date, there are still polarizing views on the suitability of tympanic membrane as a CBT site. This paper will revisit a number of key unresolved issues in the literature and also presents, for the first time, a benchmark of the middle ear temperature against temperature measurements from other sites. Results from experiments carried out on human and primate subjects will be presented to draw a fresh set of insights against the backdrop of hypotheses and controversies. PMID:28414722

  7. CORRELATION BETWEEN SOME BODY MEASURES OF LIPPIZANER STALLION PER LINES AT ĐAKOVO STUD

    Directory of Open Access Journals (Sweden)

    T. Rastija

    2002-06-01

    Full Text Available Body measures of Lippizaner line stallions and their correlation were processed in Đakovo stud. The measures performed by Lydtin rod and stock band included withers height, chest girth and cannon bone circumference on the total of 75 heads. Neapolitano line was characterized by the fewest number of stallions (4 whereas Tulip by the largest one (20. Data attained by the measuring were processed by the statistical program SPSS/PC (Nie et. al. 1975. Neapolitano line stallions had the lowest withers height (164.00 cm measured by the band whereas Conversano line stallions had the highest one (166.33 cm. Withers height measured by the rod was the lowest in the Maestoso line stallion (156.50 cm and the highest one in the Favory line (159.20 cm. Chest girth ranged between 183.82 cm (Pluto line and 186.89 cm (Conversano line. Cannon bone circumference was uniform with all lines ranged from 20.05 cm (Tulipan line and 20.65 cm (Maestoso lines. Correlation between withers height measured by the band and rod and that one measured by the rod and chest girth was positive and highly significant. However, correlation between others ranged from slight positive to slight negative. Neapolitano line was known for the most pronounced correlation per lines whereas Tulip line for the weakest one. Correlation between withers height measured by the band and rod was in all lines highly significant (except Tulip line whereas other correlation varied from positive to negative.

  8. Precision of MRI-based body composition measurements of postmenopausal women

    Science.gov (United States)

    Romu, Thobias; Thorell, Sofia; Lindblom, Hanna; Berin, Emilia; Holm, Anna-Clara Spetz; Åstrand, Lotta Lindh; Karlsson, Anette; Borga, Magnus; Hammar, Mats; Leinhard, Olof Dahlqvist

    2018-01-01

    Objectives To determine precision of magnetic resonance imaging (MRI) based fat and muscle quantification in a group of postmenopausal women. Furthermore, to extend the method to individual muscles relevant to upper-body exercise. Materials and methods This was a sub-study to a randomized control trial investigating effects of resistance training to decrease hot flushes in postmenopausal women. Thirty-six women were included, mean age 56 ± 6 years. Each subject was scanned twice with a 3.0T MR-scanner using a whole-body Dixon protocol. Water and fat images were calculated using a 6-peak lipid model including R2*-correction. Body composition analyses were performed to measure visceral and subcutaneous fat volumes, lean volumes and muscle fat infiltration (MFI) of the muscle groups’ thigh muscles, lower leg muscles, and abdominal muscles, as well as the three individual muscles pectoralis, latissimus, and rhomboideus. Analysis was performed using a multi-atlas, calibrated water-fat separated quantification method. Liver-fat was measured as average proton density fat-fraction (PDFF) of three regions-of-interest. Precision was determined with Bland-Altman analysis, repeatability, and coefficient of variation. Results All of the 36 included women were successfully scanned and analysed. The coefficient of variation was 1.1% to 1.5% for abdominal fat compartments (visceral and subcutaneous), 0.8% to 1.9% for volumes of muscle groups (thigh, lower leg, and abdomen), and 2.3% to 7.0% for individual muscle volumes (pectoralis, latissimus, and rhomboideus). Limits of agreement for MFI was within ± 2.06% for muscle groups and within ± 5.13% for individual muscles. The limits of agreement for liver PDFF was within ± 1.9%. Conclusion Whole-body Dixon MRI could characterize a range of different fat and muscle compartments with high precision, including individual muscles, in the study-group of postmenopausal women. The inclusion of individual muscles, calculated from the

  9. Cutaneous noradrenaline measured by microdialysis in complex regional pain syndrome during whole-body cooling and heating

    DEFF Research Database (Denmark)

    Terkelsen, Astrid Juhl; Gierthmühlen, Janne; Petersen, Lars J.

    2013-01-01

    and in healthy volunteers. Seven patients and nine controls completed whole-body cooling (sympathetic activation) and heating (sympathetic inhibition) induced by a whole-body thermal suit with simultaneous measurement of the skin temperature, skin blood flow, and release of dermal noradrenaline. CRPS pain...

  10. Identifying cochlear implant channels with poor electrode-neuron interface: electrically-evoked auditory brainstem responses measured with the partial tripolar configuration

    Science.gov (United States)

    Bierer, Julie Arenberg; Faulkner, Kathleen F.; Tremblay, Kelly L.

    2011-01-01

    Objectives The goal of this study was to compare cochlear implant behavioral measures and electrically-evoked auditory brainstem responses (EABRs) obtained with a spatially focused electrode configuration. It has been shown previously that channels with high thresholds, when measured with the tripolar configuration, exhibit relatively broad psychophysical tuning curves (Bierer and Faulkner, 2010). The elevated threshold and degraded spatial/spectral selectivity of such channels are consistent with a poor electrode-neuron interface, such as suboptimal electrode placement or reduced nerve survival. However, the psychophysical methods required to obtain these data are time intensive and may not be practical during a clinical mapping procedure, especially for young children. Here we have extended the previous investigation to determine if a physiological approach could provide a similar assessment of channel functionality. We hypothesized that, in accordance with the perceptual measures, higher EABR thresholds would correlate with steeper EABR amplitude growth functions, reflecting a degraded electrode-neuron interface. Design Data were collected from six cochlear implant listeners implanted with the HiRes 90k cochlear implant (Advanced Bionics). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the partial tripolar configuration, for which a fraction of current (σ) from a center active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. EABRs were obtained in each subject for the two channels having the highest and lowest tripolar (σ=1 or 0.9) behavioral threshold. Evoked potentials were measured with both the monopolar (σ=0) and a more focused partial tripolar (σ ≥ 0.50) configuration. Results Consistent with previous studies, EABR thresholds were highly and positively correlated with behavioral thresholds

  11. Identifying cochlear implant channels with poor electrode-neuron interfaces: electrically evoked auditory brain stem responses measured with the partial tripolar configuration.

    Science.gov (United States)

    Bierer, Julie Arenberg; Faulkner, Kathleen F; Tremblay, Kelly L

    2011-01-01

    The goal of this study was to compare cochlear implant behavioral measures and electrically evoked auditory brain stem responses (EABRs) obtained with a spatially focused electrode configuration. It has been shown previously that channels with high thresholds, when measured with the tripolar configuration, exhibit relatively broad psychophysical tuning curves. The elevated threshold and degraded spatial/spectral selectivity of such channels are consistent with a poor electrode-neuron interface, defined as suboptimal electrode placement or reduced nerve survival. However, the psychophysical methods required to obtain these data are time intensive and may not be practical during a clinical mapping session, especially for young children. Here, we have extended the previous investigation to determine whether a physiological approach could provide a similar assessment of channel functionality. We hypothesized that, in accordance with the perceptual measures, higher EABR thresholds would correlate with steeper EABR amplitude growth functions, reflecting a degraded electrode-neuron interface. Data were collected from six cochlear implant listeners implanted with the HiRes 90k cochlear implant (Advanced Bionics). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the partial tripolar configuration, for which a fraction of current (σ) from a center active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. EABRs were obtained in each subject for the two channels having the highest and lowest tripolar (σ = 1 or 0.9) behavioral threshold. Evoked potentials were measured with both the monopolar (σ = 0) and a more focused partial tripolar (σ ≥ 0.50) configuration. Consistent with previous studies, EABR thresholds were highly and positively correlated with behavioral thresholds obtained with both the monopolar and partial

  12. Assessing the Nonequilibrium Thermodynamics in a Quenched Quantum Many-Body System via Single Projective Measurements

    Directory of Open Access Journals (Sweden)

    L. Fusco

    2014-08-01

    Full Text Available We analyze the nature of the statistics of the work done on or by a quantum many-body system brought out of equilibrium. We show that, for the sudden quench and for an initial state that commutes with the initial Hamiltonian, it is possible to retrieve the whole nonequilibrium thermodynamics via single projective measurements of observables. We highlight, in a physically clear way, the qualitative implications for the statistics of work coming from considering processes described by operators that either commute or do not commute with the unperturbed Hamiltonian of a given system. We consider a quantum many-body system and derive an expression that allows us to give a physical interpretation, for a thermal initial state, to all of the cumulants of the work in the case of quenched operators commuting with the unperturbed Hamiltonian. In the commuting case, the observables that we need to measure have an intuitive physical meaning. Conversely, in the noncommuting case, we show that, although it is possible to operate fully within the single-measurement framework irrespectively of the size of the quench, some difficulties are faced in providing a clear-cut physical interpretation to the cumulants. This circumstance makes the study of the physics of the system nontrivial and highlights the nonintuitive phenomenology of the emergence of thermodynamics from the fully quantum microscopic description. We illustrate our ideas with the example of the Ising model in a transverse field showing the interesting behavior of the high-order statistical moments of the work distribution for a generic thermal state and linking them to the critical nature of the model itself.

  13. Accuracy and reproducibility of adipose tissue measurements in young infants by whole body magnetic resonance imaging.

    Science.gov (United States)

    Bauer, Jan Stefan; Noël, Peter Benjamin; Vollhardt, Christiane; Much, Daniela; Degirmenci, Saliha; Brunner, Stefanie; Rummeny, Ernst Josef; Hauner, Hans

    2015-01-01

    MR might be well suited to obtain reproducible and accurate measures of fat tissues in infants. This study evaluates MR-measurements of adipose tissue in young infants in vitro and in vivo. MR images of ten phantoms simulating subcutaneous fat of an infant's torso were obtained using a 1.5T MR scanner with and without simulated breathing. Scans consisted of a cartesian water-suppression turbo spin echo (wsTSE) sequence, and a PROPELLER wsTSE sequence. Fat volume was quantified directly and by MR imaging using k-means clustering and threshold-based segmentation procedures to calculate accuracy in vitro. Whole body MR was obtained in sleeping young infants (average age 67±30 days). This study was approved by the local review board. All parents gave written informed consent. To obtain reproducibility in vivo, cartesian and PROPELLER wsTSE sequences were repeated in seven and four young infants, respectively. Overall, 21 repetitions were performed for the cartesian sequence and 13 repetitions for the PROPELLER sequence. In vitro accuracy errors depended on the chosen segmentation procedure, ranging from 5.4% to 76%, while the sequence showed no significant influence. Artificial breathing increased the minimal accuracy error to 9.1%. In vivo reproducibility errors for total fat volume of the sleeping infants ranged from 2.6% to 3.4%. Neither segmentation nor sequence significantly influenced reproducibility. With both cartesian and PROPELLER sequences an accurate and reproducible measure of body fat was achieved. Adequate segmentation was mandatory for high accuracy.

  14. Accuracy and reproducibility of adipose tissue measurements in young infants by whole body magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Jan Stefan Bauer

    Full Text Available MR might be well suited to obtain reproducible and accurate measures of fat tissues in infants. This study evaluates MR-measurements of adipose tissue in young infants in vitro and in vivo.MR images of ten phantoms simulating subcutaneous fat of an infant's torso were obtained using a 1.5T MR scanner with and without simulated breathing. Scans consisted of a cartesian water-suppression turbo spin echo (wsTSE sequence, and a PROPELLER wsTSE sequence. Fat volume was quantified directly and by MR imaging using k-means clustering and threshold-based segmentation procedures to calculate accuracy in vitro. Whole body MR was obtained in sleeping young infants (average age 67±30 days. This study was approved by the local review board. All parents gave written informed consent. To obtain reproducibility in vivo, cartesian and PROPELLER wsTSE sequences were repeated in seven and four young infants, respectively. Overall, 21 repetitions were performed for the cartesian sequence and 13 repetitions for the PROPELLER sequence.In vitro accuracy errors depended on the chosen segmentation procedure, ranging from 5.4% to 76%, while the sequence showed no significant influence. Artificial breathing increased the minimal accuracy error to 9.1%. In vivo reproducibility errors for total fat volume of the sleeping infants ranged from 2.6% to 3.4%. Neither segmentation nor sequence significantly influenced reproducibility.With both cartesian and PROPELLER sequences an accurate and reproducible measure of body fat was achieved. Adequate segmentation was mandatory for high accuracy.

  15. Measurements of Total and Partial Charge-changing Cross Sections for 200-400 MeV/nucleon 12C in Water and Polycarbonate

    Energy Technology Data Exchange (ETDEWEB)

    Toshito, T.; /CREST, Japan Sci. Tech. Corp. /KEK, Tsukuba; Kodama, K.; /Aichi U. of Education; Sihver, L.; /Chalmers U. Tech.; Yusa, K.; /Gunma U., Maebashi; Ozaki, M.; /JAXA, Sagamihara; Amako, K.; Kameoka, S.; Murakami, K.; Sasaki, T.; /KEK, Tsukuba; Aoki, S.; /Kobe U.; Ban, T.; Fukuda, T.; Komatsu, M.; Kubota, H.; Naganawa, N.; Nakamura, T.; Nakano, T.; Natsume, M.; Niwa, K.; Takahashi, S.; Yoshida, J.; /Nagoya U. /Naruto U. of Education /NIRS, Chiba /SLAC /Toho U.

    2011-11-10

    We have studied charged nuclear fragments produced by 200 - 400 MeV/nucleon carbon ions, interacting with water and polycarbonate, using a newly developed emulsion detector. Total and partial charge-changing cross sections for the production of B, Be, and Li fragments were measured and compared with both previously published measurements, and model predictions. This study is of importance for validating and improving carbon ion therapy treatment planning systems, and for estimating the radiological risks for personnel on space missions, since carbon is a significant component of the Galactic Cosmic Rays.

  16. Body cell mass measured by bioimpedance spectroscopy as a nutritional marker.

    Directory of Open Access Journals (Sweden)

    Aleksandra Rymarz

    2012-06-01

    Full Text Available Body Cell Mass (BCM is a sum of all metabolically active cells of the body. Aim of the study was to compare BCM with other nutritional and inflammatory markers in patients with chronic kidney disease (CKD stage 4-5 (NKF without dialysis treatment and in hemodialysis patients(HD. We included 45 adult patients with CKD and eGFR<30 ml/min not treated with dialysis (26 male, age: 59,7±16,8 and 39 adults treated with HD three times a week, for more than three months (26 male, 5 diabetics, age: 59,8 ±16. Body composition was measured using multifrequency biopimpedance spectroscopy: Body Composition Monitor - FMC. We used BCM index (BCMI defined as BCM divided by height to the power of 2. To measure hand grip strength (HGS we used dynamometr Jamar. In statistics analysis we used Pearson correlations (SPSS v18. Predialysis group: BCMI: 7,1 ±1,6 kg/m², Lean Tissue Index (LTI: 12,9 ±2,4 kg/m², Fat Tissue Index (FTI: 14,7 ±5,4 kg/m², BMI: 28,2 ±5 kg/m², serum creatinine level (SCr: 3,9 ±2,1 mg/dl, eGFR: 18,3 ±7,0034 ml/min/1,73 m², albumin (SA: 3,9 ±0,3 g/dl, prealbumin (PA: 32,8 ±8,8 mg/dl, CRP: 0,5 ±0,3 mg/dl. A positive correlation was found with BCMI and HGS (r = 0,55; p=0,001, PA (r = 0,41; p=0,004 and SCr (r =0,37; p=0,012. A negative correlation was found between BCMI and age (r = -0,48; p=0,006, CRP (r = -0,33; p=0,028. We do not observed correlation with BMI and SA. HD group: BCMI: 6,4±1,7 kg/m², LTI: 12,1±2,3 kg/m², FTI: 12 ±6 kg/m², BMI: 24,8 ±4,8, SCr: 8,9 ±2,6 mg/dl, TP: 6,7 ±0,6 g/dl, SA: 3,9 ±0,47 g/dl, PA 33,8 ±11,4 g/dl, CRP: 1,1 ±1,4 mg/dl. A positive, significant correlation was found between BCMI and HGS (r = 0,47; p=0,003. A negative correlation was found with BCMI and age (r = -0,55; p=0,0005 and with CRP (r = -0,31, but not statistically significant. We do not observed correlation between BCMI and BMI, SCr, TP, SA, PA, hemodialysis vintage, Kt/V. Assessment of body compartments is

  17. Body contour measurements by conoscopy: application in nuclear medicine, study of feasibility

    International Nuclear Information System (INIS)

    Scheiber, C.; Musse, O.; Mallet, Y.; Sirat, G.

    1997-01-01

    The aim of this study was to obtain a precise mapping of the human body contours as viewed by the gamma camera during acquisition for pathological focus detection and as intermediary in the fusion with morphological images sources (CT, IRM, US). The measurement of the human body contours, making use of a telemeter system, was proposed by O. Peria (Ph.D Thesis, University of Grenoble) by using a laser telemeter and then structured-light sources. We proposed utilization of a non-coherent interferometer, the conoscope developed by G. Sirat, coupled to an electro-mechanical sweeping system mounted on the gamma camera rack. The first tests realized with a slow prototype (3 pt/s), have allowed the recording of visage contours (a profile obtained by angular rotation of the camera (10 deg.) on an (Elscint, Haifa) Helix gamma camera). For this experiment the voluntary subject has worn protection spectacles (the light source being a laser of 1 mW). Among the advantages of this compact system (14 x 10 x 15 cm) we stress: a) a high precision (0.2 mm); b) being installed on the rack, the calibration procedures are simplified and their shifts are potentially reduced; c) the procedures of intra-modality image matching is simplified; d) an integrated fast electronic circuitry (DSP) allows to exploit directly, in real time if necessary, the obtained results (x,y,z coordinates of the studied point). We considered that by its precision, its insensitivity to luminous environment conditions and its integration with the turning gamma camera, the system deserves to be evaluated for application in medical imaging. This system as other intermediate captors, using body contours, allows the superimposing of data, other than the image data, what helps the stereotaxic localization

  18. Measurement of the body content of sodium, potassium, chloride, calcium, phophorus and nitrogen with reference to spironolactone

    International Nuclear Information System (INIS)

    Boddy, K.

    1978-01-01

    The total body content of sodium, chloride, nitrogen, calcium and phosphorus can be measured simultaneously by in vivo activation analysis and at the same time total body potassium can be determined directly by whole body counting. These procedures have been described and compared with methods using isotope dilution. The complementary nature of the techniques, when properly applied, as well as reported disparities have been illustrated by a number of clinical investigations generally involving aldosterone antagonists. The methods should provide a better insight to the complex changes in body conposition and metabolism accociated with hypertension (and other diseases) and their treatment. (Auth.)

  19. Subject positioning in the BOD POD® only marginally affects measurement of body volume and estimation of percent body fat in young adult men.

    Directory of Open Access Journals (Sweden)

    Maarten W Peeters

    Full Text Available INTRODUCTION: The aim of the study was to evaluate whether subject positioning would affect the measurement of raw body volume, thoracic gas volume, corrected body volume and the resulting percent body fat as assessed by air displacement plethysmography (ADP. METHODS: Twenty-five young adult men (20.7±1.1 y, BMI = 22.5±1.4 kg/m(2 were measured using the BOD POD® system using a measured thoracic gas volume sitting in a 'forward bent' position and sitting up in a straight position in random order. RESULTS: Raw body volume was 58±124 ml (p<0.05 higher in the 'straight' position compared to the 'bent' position. The mean difference in measured thoracic gas volume (bent-straight = -71±211 ml was not statistically significant. Corrected body volume and percent body fat in the bent position consequently were on average 86±122 ml (p<0.05 and 0.5±0.7% (p<0.05 lower than in the straight position respectively. CONCLUSION: Although the differences reached statistical significance, absolute differences are rather small. Subject positioning should be viewed as a factor that may contribute to between-test variability and hence contribute to (inprecision in detecting small individual changes in body composition, rather than a potential source of systematic bias. It therefore may be advisable to pay attention to standardizing subject positioning when tracking small changes in PF are of interest. The cause of the differences is shown not to be related to changes in the volume of isothermal air in the lungs. It is hypothesized and calculated that the observed direction and magnitude of these differences may arise from the surface area artifact which does not take into account that a subject in the bent position exposes more skin to the air in the device therefore potentially creating a larger underestimation of the actual body volume due to the isothermal effect of air close to the skin.

  20. Comparison of a triaxial fluxgate magnetometer and Toftness sensometer for body surface EMF measurement.

    Science.gov (United States)

    Zhang, John; Toftness, Dave; Snyder, Brian; Nosco, Dennis; Balcavage, Walter; Nindl, Gabi

    2004-12-01

    The use of magnetic fields to treat disease has intrigued mankind since the time of the ancient Greeks. More recently it has been shown that electromagnetic field (EMF) treatment aids bone healing, and repetitive transcranial magnetic stimulation (rTMS) appears to be beneficial in treating schizophrenia and depression. Since external EMFs influence internal body processes, we hypothesized that measurement of body surface EMFs might be used to detect disease states and direct the course of subsequent therapy. However, measurement of minute body surface EMFs requires use of a sensitive and well documented magnetometer. In this study we evaluated the sensitivity and frequency response of a fluxgate magnetometer with a triaxial probe for use in detecting body surface EMF and we compared the magnetometer readings with a signal from a Toftness Sensometer, operated by an experienced clinician, in the laboratory and in a clinical setting. A Peavy Audio Amplifier and variable power output Telulex signal generator were used to develop 50 microT EMFs in a three coil Merritt coil system. A calibrated magnetometer was used to set a 60 Hz 50 microT field in the coil and an ammeter was used to measure the current required to develop the 50 microT field. At frequencies other than 60 Hz, the field strength was maintained at 50 microT by adjusting the Telulex signal output to keep the current constant. The field generated was monitored using a 10 turn coil connected to an oscilloscope. The oscilloscope reading indicated that the field strength was the same at all frequencies tested. To determine if there was a correspondence between the signals detected by a fluxgate magnetometer (FGM1) and the Toftness Sensometer both devices were placed in the Merritt coil and readings were recorded from the FGM1 and compared with the ability of a highly experienced Toftness operator to detect the 50 microT field. Subsequently, in a clinical setting, FGM1 readings made by an FGM1 technician and

  1. Development of methods for body composition studies

    International Nuclear Information System (INIS)

    Mattsson, Soeren; Thomas, Brian J

    2006-01-01

    This review is focused on experimental methods for determination of the composition of the human body, its organs and tissues. It summarizes the development and current status of fat determinations from body density, total body water determinations through the dilution technique, whole and partial body potassium measurements for body cell mass estimates, in vivo neutron activation analysis for body protein measurements, dual-energy absorptiometry (DEXA), computed tomography (CT) and magnetic resonance imaging (MRI, fMRI) and spectroscopy (MRS) for body composition studies on tissue and organ levels, as well as single- and multiple-frequency bioimpedance (BIA) and anthropometry as simple easily available methods. Methods for trace element analysis in vivo are also described. Using this wide range of measurement methods, together with gradually improved body composition models, it is now possible to quantify a number of body components and follow their changes in health and disease. (review)

  2. Development of methods for body composition studies

    Energy Technology Data Exchange (ETDEWEB)

    Mattsson, Soeren [Department of Radiation Physics, Lund University, Malmoe University Hospital, SE-205 02 Malmoe (Sweden); Thomas, Brian J [School of Physical and Chemical Sciences, Queensland University of Technology, Brisbane, QLD 4001 (Australia)

    2006-07-07

    This review is focused on experimental methods for determination of the composition of the human body, its organs and tissues. It summarizes the development and current status of fat determinations from body density, total body water determinations through the dilution technique, whole and partial body potassium measurements for body cell mass estimates, in vivo neutron activation analysis for body protein measurements, dual-energy absorptiometry (DEXA), computed tomography (CT) and magnetic resonance imaging (MRI, fMRI) and spectroscopy (MRS) for body composition studies on tissue and organ levels, as well as single- and multiple-frequency bioimpedance (BIA) and anthropometry as simple easily available methods. Methods for trace element analysis in vivo are also described. Using this wide range of measurement methods, together with gradually improved body composition models, it is now possible to quantify a number of body components and follow their changes in health and disease. (review)

  3. Partial Cancellation

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Partial Cancellation. Full Cancellation is desirable. But complexity requirements are enormous. 4000 tones, 100 Users billions of flops !!! Main Idea: Challenge: To determine which cross-talker to cancel on what “tone” for a given victim. Constraint: Total complexity is ...

  4. Global Ocean Surface Water Partial Pressure of CO2 Database: Measurements Performed During 1968-2007 (Version 2007)

    Energy Technology Data Exchange (ETDEWEB)

    Kozyr, Alex [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Carbon Dioxide Information Analysis Center

    2008-09-30

    More than 4.1 million measurements of surface water partial pressure of CO2 obtained over the global oceans during 1968-2007 are listed in the Lamont-Doherty Earth Observatory (LDEO) database, which includes open ocean and coastal water measurements. The data assembled include only those measured by equilibrator-CO2 analyzer systems and have been quality-controlled based on the stability of the system performance, the reliability of calibrations for CO2 analysis, and the internal consistency of data. To allow re-examination of the data in the future, a number of measured parameters relevant to pCO2 measurements are listed. The overall uncertainty for the pCO2 values listed is estimated to be ± 2.5 µatm on the average. For simplicity and for ease of reference, this version is referred to as 2007, meaning that data collected through 31 December 2007 has been included. It is our intention to update this database annually. There are 37 new cruise/ship files in this update. In addition, some editing has been performed on existing files so this should be considered a V2007 file. Also we have added a column reporting the partial pressure of CO2 in seawater in units of Pascals. The data presented in this database include the analyses of partial pressure of CO2 (pCO2), sea surface temperature (SST), sea surface salinity (SSS), pressure of the equilibration, and barometric pressure in the outside air from the ship’s observation system. The global pCO2 data set is available free of charge as a numeric data package (NDP) from the Carbon Dioxide Information Analysis Center (CDIAC). The NDP consists of the oceanographic data files and this printed documentation, which describes the procedures and methods used to obtain the data.

  5. Clinical measurements of part-body calcium using neutron activation analysis

    International Nuclear Information System (INIS)

    Tothill, P.; Smith, M.A.; Simpson, J.D.; Chew, I.; MacPherson, J.N.; Winney, R.J.; Strong, J.A.

    1979-01-01

    Californium-252 sources have been used in a clinical environment for neutron activation analysis studies for a period of 2 1/2 years. During this period, changes in bone calcium in response to different treatment regimes have been measured in patients suffering from primary or secondary bone disease. The first measurements were performed on peripheral bone, in particular the forearm, using two sources of 252 Cf, minimum total activity 56mCi, for bilateral irradiation and two 15cmx10cm NaI crystals for detection. Optimization of the irradiation geometry and the patient irradiation programme enabled measurements to be performed with a precision of 1.6% and a dose of 3 rem. The precision estimate was based on 64 sets of repeated patient measurements and included errors due to patient movement. Apparatus was also developed to measure changes of calcium in the lumbar spine, particular attention being devoted to obtaining uniformity of sensitivity in the vertebrae. Unilateral irradiation with two 252 Cf sources, activity 100mCi each, separated by 20cm, and detection in whole-body counter with four 15cmx10cm NaI detectors gave a precision of 2% based on repeated measurements of 10 patients, with a dose of 1.3 rem to the spine and 10 rem to the skin surface. The following studies were undertaken: the effect of 1 α-hydroxycholecalciferol on 19 patients undergoing chronic haemodialysis, the use of vitamin D 2 and vitamin D 3 in the treatment of 33 patients with potential anticonvulsant osteomalacia, the effect of lithium carbonate in 20 patients with manic depression and the efficacy of conventional treatments in combating thyrotoxic osteodystrophy. (author)

  6. Energy spectra of massive two-body decay products and mass measurement

    CERN Document Server

    Agashe, Kaustubh; Hong, Sungwoo; Kim, Doojin

    2016-01-01

    We have recently established a new method for measuring the mass of unstable particles produced at hadron colliders based on the analysis of the energy distribution of a massless product from their two-body decays. The central ingredient of our proposal is the remarkable result that, for an unpolarized decaying particle, the location of the peak in the energy distribution of the observed decay product is identical to the (fixed) value of the energy that this particle would have in the rest-frame of the decaying particle, which, in turn, is a simple function of the involved masses. In addition, we utilized the property that this energy distribution is symmetric around the location of peak when energy is plotted on a logarithmic scale. The general strategy was demonstrated in several specific cases, including both beyond the SM particles, as well as for the top quark. In the present work, we generalize this method to the case of a massive decay product from a two-body decay; this procedure is far from trivial b...

  7. FY 2000 Annual Report for EMSP Project No.70108 - Effects of Fluid Distribution on Measured Geophysical Properties for Partially Saturated, Shallow Subsurface Conditions

    International Nuclear Information System (INIS)

    Berge, P.A.; Bonner, B.P.; Roberts, J.J.; Wildenschild, D.; Aracne-Ruddle, C.M.; Berryman, J.G.; Bertete-Aguirre, H.; Boro, C.O.; Carlberg, E.D.

    2000-01-01

    Our goal is to improve geophysical imaging of the vadose zone. We will achieve this goal by providing new methods to improve interpretation of field data. The purpose of this EMSP project is to develop relationships between laboratory measured geophysical properties and porosity, saturation, and fluid distribution, for partially saturated soils. Algorithms for relationships between soil composition, saturation, and geophysical measurements will provide new methods to interpret geophysical field data collected in the vadose zone at sites such as Hanford, WA. This report summarizes work after 10 months of a 3-year project. We have modified a laboratory ultrasonics apparatus developed in a previous EMSP project (No.55411) so that we can make velocity measurements for partially-saturated samples rather than fully-saturated or dry samples. We are testing the measurement apparatus using standard laboratory sand samples such as Ottawa sand samples. Preliminary results indicate that we can measure both compressional and shear velocities in these sand samples. We have received Hanford soil samples (sands from split-spoon cores from an uncontaminated site) and expect to make ultrasonic measurements on them also. We have used the LLNL x-ray facility to perform x-ray computed tomography (XCT) imaging for several partially-saturated Ottawa sand and Lincoln sand samples, and have also used the DOE Advance Photon Source at Argonne National Laboratory to make higher-resolution images of some sand samples. Preliminary results indicate that we can image amount and distribution of fluids in homogeneous sand samples. Continuing work from the previous EMSP project, we are testing a new data analysis method for seismic data that is expected to improve interpretation of seismic data from the vadose zone by showing how partial saturation affects seismic parameters. Our results suggest that the planned approach for this research is appropriate, that microstructure is an important factor

  8. Installation with magnetic suspension of test bodies for measurement of small forces. Verification of equivalence of inertial and gravitational mass

    International Nuclear Information System (INIS)

    Kalebin, S.M.

    1988-01-01

    Torsion installation with magnetic suspension of test bodies for detection of small forces is considered. Installation application for verification of equivalence of inertial and gravitational mass in the case of test body incidence on the Earth (Etvesh experiment) and in the case of their incidene on the Sun (Dicke experiment) is discussed. The total mass of test bodies, produced in the form of cylinders with 3 cm radius, equals 50 kg (one lead body and one copper body); beam radius of test bodies equals 3 cm (the cylinders are tight against one another); ferrite cylinder with 3 cm radius and 10 cm height is used for their suspension in magnetic field. Effect of thermal noise and electromagnetic force disturbances on measurement results is considered. Conducted calculations show that suggested installation enables to improve the accuracy of verifying mentioned equivalence at least by one order and upwards. This suggests that such installation is a matter of interest for experiments on small force detection

  9. Longitudinal measurements of total body water and body composition in healthy volunteers by online breath deuterium measurement and other near-subject methods

    Czech Academy of Sciences Publication Activity Database

    Engel, B.; Španěl, Patrik; Smith, D.; Diskin, A. M.; Davis, S. J.

    2005-01-01

    Roč. 2, č. 3 (2005), s. 99-106 ISSN 1479-456X R&D Projects: GA ČR(CZ) GA203/00/0632 Institutional research plan: CEZ:AV0Z40400503 Keywords : total body water * deuterium isotope dilution * FA-MS * bio-impendance Subject RIV: CF - Physical ; Theoretical Chemistry

  10. Morphological measurements and body indices for Cuban Creole goats and their crossbreds

    Directory of Open Access Journals (Sweden)

    Edilberto Chacón

    2011-08-01

    Full Text Available In this work, linear body measures were taken and production indices calculated for 100 Cuban Creole goats and 100 crossbred goats in order to aid in the characterization of animal genetic resources in Cuba. Low variation was found for all indices of the Creole goats, showing homogeneity between the groups of animals studied. Most of the functional indices are related to the milk biotype which is in agreement the possible origin of the breed from animals of the Iberian Peninsula and Canary Islands. The crossbreds were more varied, mostly due to undesigned disorganized crossing. These data may help in identifying a commercial niche for the breed and contribute to in situ conservation of the Cuban Creole goat.

  11. Dosimetric methods and results of measurement for total body electron irradiation

    International Nuclear Information System (INIS)

    Feng Ningyuan; Yu Geng; Yu Zihao

    1987-01-01

    A modified 'STANFORD TSEI TECHNIQUE' e.g. dual angled gantry, 6 turntable angles and 12 fields was developed on PHILIPS SL 75-20 linear accelerator to treat mycosis fungoides. A plastic scatter screen, 5 mm in thickness was used to reduce the primary electron energy to 4 MeV in order to control treatment depth (d 80 approx.= 1.2 cm) and skin dose up to 89%. The X-ray contamination was at an acceptable level of 2%. This measurement which involved multiple dosimetric methods, showed that the distance between the scattor screen and the patient, within 10-30 cm, had no influence on PDD and the dose distribution on the body surface was reasonably homogeneous, but strongly dependent on the anatomic positions. For those sites which were located in the electron beam shadows, boosting irradiation might be necessary. The preliminary clinical trials indicated that this technique is valid and feasible

  12. On-farm estimation of energy balance in dairy cows using only frequent body weight measurements and body condition score

    DEFF Research Database (Denmark)

    Thorup, Vivi Mørkøre; Edwards, David; Friggens, N C

    2012-01-01

    the performance of our estimated EBalbody against the traditional EBalinout method. From 76 Danish Holstein and Jersey cows, parity 1 or 2+, on a glycogenic or ketogenic TMR, BW was measured automatically at each milking, using a weighing platform installed in an automated milking system. From within milking......, the FEC profile did not suggest any systematic bias in EBalbody with stage of lactation. Moreover we successfully modeled EBalbody differences between breeds, parities and diets. For the farmer, the ability to predict energy balance for individual cows on-farm without having to measure feed intake would...

  13. Stability of the translocation frequency following whole-body irradiation measured in rhesus monkeys

    Science.gov (United States)

    Lucas, J. N.; Hill, F. S.; Burk, C. E.; Cox, A. B.; Straume, T.

    1996-01-01

    Chromosome translocations are persistent indicators of prior exposure to ionizing radiation and the development of 'chromosome painting' to efficiently detect translocations has resulted in a powerful biological dosimetry tool for radiation dose reconstruction. However, the actual stability of the translocation frequency with time after exposure must be measured before it can be used reliably to obtain doses for individuals exposed years or decades previously. Human chromosome painting probes were used here to measure reciprocal translocation frequencies in cells from two tissues of 8 rhesus monkeys (Macaca mulatta) irradiated almost three decades previously. Six of the monkeys were exposed in 1965 to whole-body (fully penetrating) radiation and two were unexposed controls. The primates were irradiated as juveniles to single doses of 0.56, 1.13, 2.00, or 2.25 Gy. Blood lymphocytes (and skin fibroblasts from one individual) were obtained for cytogenetic analysis in 1993, near the end of the animals' lifespans. Results show identical dose-response relationships 28 y after exposure in vivo and immediately after exposure in vitro. Because chromosome aberrations are induced with identical frequencies in vivo and in vitro, these results demonstrate that the translocation frequencies induced in 1965 have not changed significantly during the almost three decades since exposure. Finally, our emerging biodosimetry data for individual radiation workers are now confirming the utility of reciprocal translocations measured by FISH in radiation dose reconstruction.

  14. Assessing internal exposures and the efficacy of countermeasures from whole body measurements

    International Nuclear Information System (INIS)

    Likhtarev, I.; Kovgan, L.; Gluvchinsky, R.; Perevoznikov, O.; Morrey, M.; Prosser, S.L.; Jacob, P.; Prohl, G.; Kenigsberg, Y.; Skryabin, A.M.; Colgen, P.A.

    1996-01-01

    Traditional procedures for modelling the ingestion dose pathway combine environmental transfer models with human metabolic models in order to assess the doses received. In general, these models have been developed for specific ecological and socio-economic circumstances, rather than for globally-averaged conditions. Experiences which occurred following the Chernobyl accident have demonstrated that in the event of a large scale radiation accident it will be virtually impossible to monitor adequately all the radiologically significant components of human diet which may have become contaminated with radionuclides. This paper describes an internal dosimetry model based on the most widely available measurements following an accident: radiocesium measurements in soil and milk, and whole body measurements in humans. One application of the model to estimate ingestion doses received by inhabitants of the northern region of the Rovno Region in Ukraine is also described. In addition, this model enables the effectiveness of food Countermeasures to be estimated. This study formed part of Joint Study Programme 5 (JSP5) on pathway analysis and dose distributions and was jointly funded by the European Commission (EC) and Commonwealth of Independent States (CIS)

  15. A wireless, compact, and scalable bioimpedance measurement system for energy-efficient multichannel body sensor solutions

    International Nuclear Information System (INIS)

    Ramos, J; Ausín, J L; Lorido, A M; Redondo, F; Duque-Carrillo, J F

    2013-01-01

    In this paper, we present the design, realization and evaluation of a multichannel measurement system based on a cost-effective high-performance integrated circuit for electrical bioimpedance (EBI) measurements in the frequency range from 1 kHz to 1 MHz, and a low-cost commercially available radio frequency transceiver device, which provides reliable wireless communication. The resulting on-chip spectrometer provides high measuring EBI capabilities and constitutes the basic node to built EBI wireless sensor networks (EBI-WSNs). The proposed EBI-WSN behaves as a high-performance wireless multichannel EBI spectrometer where the number of nodes, i.e., number of channels, is completely scalable to satisfy specific requirements of body sensor networks. One of its main advantages is its versatility, since each EBI node is independently configurable and capable of working simultaneously. A prototype of the EBI node leads to a very small printed circuit board of approximately 8 cm 2 including chip-antenna, which can operate several years on one 3-V coin cell battery. A specifically tailored graphical user interface (GUI) for EBI-WSN has been also designed and implemented in order to configure the operation of EBI nodes and the network topology. EBI analysis parameters, e.g., single-frequency or spectroscopy, time interval, analysis by EBI events, frequency and amplitude ranges of the excitation current, etc., are defined by the GUI.

  16. Precision of dual energy X-ray absorptiometry for body composition measurements in cats

    International Nuclear Information System (INIS)

    Borges, N.C.; Vasconcellos, R.S.; Canola, J.C.; Carciofi, A.C.; Pereira, G.T.; Paula, F.J.A.

    2008-01-01

    A short-term precision error of the individual subject and the DEXA technique, such as the effect of the repositioning of the cat on the examination table, were established. Four neutered adult cats (BW=4342 g) and three females (BW=3459 g) were submitted to five repeated scans with and without repositioning between them. Precision was estimated from the mean of the five measurements and expressed by the individual coefficient of variation (CV). The precision error of the technique was estimated by the variance of scan pool (n=35) and expressed in CV for the technique (CVt). The degrees of freedom and confidence intervals were determined to avoid underestimation of precision errors. Bone mineral content (BMC), lean mass (LM), and fat mass (FM) averages were higher (P<0.05) when animals were repositioned. The CVt was significantly higher (P<0.05) for bone mineral density (BMD), LM, and FM when the animals were repositioned. For short-term precision measurements, the repositioning of the animal was important to establish the precision of the technique. The dual energy xray absorptiometry method provided precision for body composition measurements in adult cats. (author)

  17. Measurement of nitrogen in the body using a commercial PGNAA system--phantom experiments.

    Science.gov (United States)

    Chichester, D L; Empey, E

    2004-01-01

    An industrial prompt-gamma neutron activation analysis (PGNAA) system, originally designed for the real-time elemental analyses of bulk coal on a conveyor belt, has been studied to examine the feasibility of using such a system for body composition analysis. Experiments were conducted to measure nitrogen in a simple, tissue equivalent phantom comprised of 2.7 wt% of nitrogen. The neutron source for these experiments was 365 MBq (18.38 microg) of 252Cf located within an engineered low Z moderator and it yielded a dose rate in the measurement position of 3.91 mSv/h; data were collected using a 2780 cm(3) NaI(Tl) cylindrical detector with a digital signal processor and a 512 channel MCA. Source, moderator and detector geometries were unaltered from the system's standard configuration, where they have been optimized for considerations such as neutron thermalization, measurement sensitivity and uniformity, background radiation and external dose minimization. Based on net counts in the 10.8 MeV PGNAA nitrogen photopeak and its escape peaks the dose dependent nitrogen count rate was 11,600 counts/mSv with an uncertainty of 3.0% after 0.32 mSv (4.9 min), 2.0% after 0.74 mSv (11.4 min) and 1.0% after 3.02 mSv (46.4 min).

  18. COMPARATIVE KINEMATIC MEASURES OF TREADMILL RUNNING WITH OR WITHOUT BODY WEIGHT SUPPORT IN RUNNERS

    Directory of Open Access Journals (Sweden)

    Duane Millslagle

    2005-12-01

    Full Text Available Treadmill walking and running using a supportive harness has been used as a training method to rehabilitate injured patients' walking or running gait. Comparison of full weight support (FWS and body weight support (BWS kinematic measures in competitive runners has received little attention. The purpose of this study was to compare selected FWS to BWS kinematic measures in healthy competitive runners. Ten male runners (age = 21.4 ± 1.5 years with a training regimen averaging 64 km per week at 3.8 m·s-1 participated. All participants ran three 3-minute trials. The randomized trial conditions were: FWS, 20% BWS, and 40% BWS. All conditions were videotaped with 2 cameras and a 21-point, 3-D model was generated for analysis. From the position-time data, cycle length (CL, cycle frequency (CF, time of contact (TC, hip-, knee-, ankle- range of motion in degrees (H-ROM, K-ROM, and A-ROM, respectively, and vertical displacement of the center of mass (COM were derived and compared. With increasing support conditions, cycle length increased. Cycle frequency, hip and ankle angle ranges, and COM vertical displacement decreased (p 0.05. BWS running produced significant changes in selected kinematic measures. These changes may provide insight into runners' behavior when using BWS in training or recovery from competition. Additional investigation of BWS training affect with competitive runners would be recommended

  19. Effect of body position on respiratory system volumes in anesthetized red-tailed hawks (Buteo jamaicensis) as measured via computed tomography.

    Science.gov (United States)

    Malka, Shachar; Hawkins, Michelle G; Jones, James H; Pascoe, Peter J; Kass, Philip H; Wisner, Erik R

    2009-09-01

    To determine the effects of body position on lung and air-sac volumes in anesthetized and spontaneously breathing red-tailed hawks (Buteo jamaicensis). 6 adult red-tailed hawks (sex unknown). A crossover study design was used for quantitative estimation of lung and air-sac volumes in anesthetized hawks in 3 body positions: dorsal, right lateral, and sternal recumbency. Lung volume, lung density, and air-sac volume were calculated from helical computed tomographic (CT) images by use of software designed for volumetric analysis of CT data. Effects of body position were compared by use of repeated-measures ANOVA and a paired Student t test. Results for all pairs of body positions were significantly different from each other. Mean +/- SD lung density was lowest when hawks were in sternal recumbency (-677 +/- 28 CT units), followed by right lateral (-647 +/- 23 CT units) and dorsal (-630 +/- 19 CT units) recumbency. Mean lung volume was largest in sternal recumbency (28.6 +/- 1.5 mL), followed by right lateral (27.6 +/- 1.7 mL) and dorsal (27.0 +/- 1.5 mL) recumbency. Mean partial air-sac volume was largest in sternal recumbency (27.0 +/- 19.3 mL), followed by right lateral (21.9 +/- 16.1 mL) and dorsal (19.3 +/- 16.9 mL) recumbency. In anesthetized red-tailed hawks, positioning in sternal recumbency resulted in the greatest lung and air-sac volumes and lowest lung density, compared with positioning in right lateral and dorsal recumbency. Additional studies are necessary to determine the physiologic effects of body position on the avian respiratory system.

  20. Measuring body composition and energy expenditure in children with severe neurologic impairment and intellectual disability

    NARCIS (Netherlands)

    Rieken, Rob; van Goudoever, Johannes B.; Schierbeek, Henk; Willemsen, Sten P.; Calis, Elsbeth A. C.; Tibboel, Dick; Evenhuis, Heleen M.; Penning, Corine

    2011-01-01

    Accurate prediction equations for estimating body composition and total energy expenditure (TEE) in children with severe neurologic impairment and intellectual disability are currently lacking. The objective was to develop group-specific equations to predict body composition by using

  1. Partial processing

    International Nuclear Information System (INIS)

    1978-11-01

    This discussion paper considers the possibility of applying to the recycle of plutonium in thermal reactors a particular method of partial processing based on the PUREX process but named CIVEX to emphasise the differences. The CIVEX process is based primarily on the retention of short-lived fission products. The paper suggests: (1) the recycle of fission products with uranium and plutonium in thermal reactor fuel would be technically feasible; (2) it would, however, take ten years or more to develop the CIVEX process to the point where it could be launched on a commercial scale; (3) since the majority of spent fuel to be reprocessed this century will have been in storage for ten years or more, the recycling of short-lived fission products with the U-Pu would not provide an effective means of making refabrication fuel ''inaccessible'' because the radioactivity associated with the fission products would have decayed. There would therefore be no advantage in partial processing

  2. Partial gigantism

    Directory of Open Access Journals (Sweden)

    М.М. Karimova

    2017-05-01

    Full Text Available A girl with partial gigantism (the increased I and II fingers of the left foot is being examined. This condition is a rare and unresolved problem, as the definite reason of its development is not determined. Wait-and-see strategy is recommended, as well as correcting operations after closing of growth zones, and forming of data pool for generalization and development of schemes of drug and radial therapeutic methods.

  3. Psoas muscle cross-sectional area as a measure of whole body lean muscle mass in maintenance hemodialysis patients

    Science.gov (United States)

    Morrell, Glen R.; Ikizler, Talat A.; Chen, Xiaorui; Heilbrun, Marta E.; Wei, Guo; Boucher, Robert; Beddhu, Srinivasan

    2016-01-01

    Objective We investigate whether psoas or paraspinous muscle area measured on a single L4–5 image is a useful measure of whole lean body mass compared to dedicated mid-thigh magnetic resonance imaging (MRI). Design Observational study. Setting Outpatient dialysis units and a research clinic. Subjects 105 adult participants on maintenance hemodialysis. No control group was used. Exposure variables Psoas muscle area, paraspinous muscle area, and mid-thigh muscle area (MTMA) were measured by MRI. Main outcome measure Lean body mass was measured by dual-energy absorptiometry (DEXA) scan. Results In separate multivariable linear regression models, psoas, paraspinous, and mid-thigh muscle area were associated with increase in lean body mass. In separate multivariate logistic regression models, c-statistics for diagnosis of sarcopenia (defined as lean body mass) were 0.69 for paraspinous muscle area, 0.81 for psoas muscle area, and 0.89 for mid-thigh muscle area. With sarcopenia defined as lean body mass, the corresponding c-statistics were 0.71, 0.92, and 0.94. Conclusions We conclude that psoas muscle area provides a good measure of whole body muscle mass, better than paraspinous muscle area but slightly inferior to mid thigh measurement. Hence, in body composition studies a single axial MR image at the L4–L5 level can be used to provide information on both fat and muscle and may eliminate the need for time-consuming measurement of muscle area in the thigh. PMID:26994780

  4. Characterization and calibration of piezoelectric polymers: In situ measurements of body vibrations

    Science.gov (United States)

    Kappel, Marcel; Abel, Markus; Gerhard, Reimund

    2011-07-01

    Piezoelectric polymers are known for their flexibility in applications, mainly due to their bending ability, robustness, and variable sensor geometry. It is an optimal material for minimal-invasive investigations in vibrational systems, e.g., for wood, where acoustical impedance matches particularly well. Many applications may be imagined, e.g., monitoring of buildings, vehicles, machinery, alarm systems, such that our investigations may have a large impact on technology. Longitudinal piezoelectricity converts mechanical vibrations normal to the polymer-film plane into an electrical signal, and the respective piezoelectric coefficient needs to be carefully determined in dependence on the relevant material parameters. In order to evaluate efficiency and durability for piezopolymers, we use polyvinylidene fluoride and measure the piezoelectric coefficient with respect to static pressure, amplitude of the dynamically applied force, and long-term stability. A known problem is the slow relaxation of the material towards equilibrium, if the external pressure changes; here, we demonstrate how to counter this problem with careful calibration. Since our focus is on acoustical measurements, we determine accurately the frequency response curve - for acoustics probably the most important characteristic. Eventually, we show that our piezopolymer transducers can be used as a calibrated acoustical sensors for body vibration measurements on a wooden musical instrument, where it is important to perform minimal-invasive measurements. A comparison with the simultaneously recorded airborne sound yields important insight of the mechanism of sound radiation in comparison with the sound propagating in the material. This is especially important for transient signals, where not only the long-living eigenmodes contribute to the sound radiation. Our analyses support that piezopolymer sensors can be employed as a general tool for the determination of the internal dynamics of vibrating systems.

  5. Wide range of body composition measures are associated with cognitive function in community-dwelling older adults.

    Science.gov (United States)

    Won, Huiloo; Abdul Manaf, Zahara; Mat Ludin, Arimi Fitri; Shahar, Suzana

    2017-04-01

    Studies of the association between body composition, both body fat and body muscle, and cognitive function are rarely reported. The aim of the present study was to determine the association between a wide range of body composition measures with cognitive function in older adults. A total of 2322 Malaysian older adults aged 60 years and older were recruited using multistage random sampling in a population-based cross-sectional study. Out of 2322 older adults recruited, 2309 (48% men) completed assessments on cognitive function and body composition. Cognitive functions were assessed using the Malay version of the Mini-Mental State Examination, the Bahasa Malaysia version of Montreal Cognitive Assessment, Digit Span Test, Digit Symbol Test and Rey Auditory Verbal Learning Test. Body composition included body mass index, mid-upper arm circumference, waist circumference, calf circumference, waist-to-hip ratio, percentage body fat and skeletal muscle mass. The association between body composition and cognitive functions was analyzed using multiple linear regression. After adjustment for age, education years, hypertension, hypercholesterolemia, diabetes mellitus, depression, smoking status and alcohol consumption, we found that calf circumference appeared as a significant predictor for all cognitive tests among both men and women (P cognitive tests among women (P Cognitive Assessment among men (P older adults for optimal cognitive function. Geriatr Gerontol Int 2017; 17: 554-560. © 2016 Japan Geriatrics Society.

  6. Standard partial molar heat capacities and enthalpies of formation of aqueous aluminate under hydrothermal conditions from integral heat of solution measurements

    International Nuclear Information System (INIS)

    Coulier, Yohann; Tremaine, Peter R.

    2014-01-01

    Highlights: • Heats of solution of NaAlO 2 (s) were measured at five temperatures up to 250 °C. • Standard molar enthalpies of solution were determined from the measured heats of solution. • Standard molar enthalpies of solution were correlated with the density model. • The density model allows us to determine the standard molar heat capacities of reaction. - Abstract: Heats of solution of sodium aluminum oxide, NaAlO 2 (s), were measured in aqueous sodium hydroxide solutions using a Tian–Calvet heat-flow calorimeter (Setaram, Model C80) with high pressure “batch cells” made of hastelloy C-276, at five temperatures from (373.15 to 523.15) K, steam saturation pressure, and concentrations from (0.02 to 0.09) mol · kg −1 . Standard molar enthalpies of solution, Δ soln H ∘ , and relative standard molar enthalpies, [H ∘ (T) − H ∘ (298.15 K)], of NaAl(OH) 4 (aq) were determined from the measured heats of solution. The results were fitted with the “density” model. The temperature dependence of Δ soln H ∘ from the model yielded the standard molar heat capacities of reaction, Δ soln C p ∘ , from which standard partial molar heat capacities for aqueous aluminate, C p ∘ [A1(OH) 4 − ,aq], were calculated. Standard partial molar enthalpies of formation, Δ f H ∘ , and entropies, S ∘ , of A1(OH) 4 − (aq) were also determined. The values for C p ∘ [A1(OH) 4 − ,aq] agree with literature data determined up to T = 413 K from enthalpy of solution and heat capacity measurements to within the combined experimental uncertainties. They are consistent with differential heat capacity measurements up to T = 573 K from Schrödle et al. (2010) [29] using the same calorimeter, but this method has the advantage that measurements could be made at much lower concentrations in the presence of an excess concentration of ligand. To our knowledge, these are the first standard partial molar heat capacities measured under hydrothermal conditions by the

  7. Motor excitability measurements: the influence of gender, body mass index, age and temperature in healthy controls.

    Science.gov (United States)

    Casanova, I; Diaz, A; Pinto, S; de Carvalho, M

    2014-04-01

    The technique of threshold tracking to test axonal excitability gives information about nodal and internodal ion channel function. We aimed to investigate variability of the motor excitability measurements in healthy controls, taking into account age, gender, body mass index (BMI) and small changes in skin temperature. We examined the left median nerve of 47 healthy controls using the automated threshold-tacking program, QTRAC. Statistical multiple regression analysis was applied to test relationship between nerve excitability measurements and subject variables. Comparisons between genders did not find any significant difference (P>0.2 for all comparisons). Multiple regression analysis showed that motor amplitude decreases with age and temperature, stimulus-response slope decreases with age and BMI, and that accommodation half-time decrease with age and temperature. The changes related to demographic features on TRONDE protocol parameters are small and less important than in conventional nerve conduction studies. Nonetheless, our results underscore the relevance of careful temperature control, and indicate that interpretation of stimulus-response slope and accommodation half-time should take into account age and BMI. In contrast, gender is not of major relevance to axonal threshold findings in motor nerves. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  8. CP Violation and Lifetime Measurements of Two-body Charmless Decays of B Hadrons at LHCb

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00453516; Eklund, Lard

    This thesis presents lifetime measurements of charmless two-body decays of b hadrons, specifically the decay modes known as $B\\to h^+ h^{'-}$, where $B$ refers to meson or baryon containing a $b$ quark and $h^{(')}$ refers to a proton $p$, pion $\\pi$ or kaon $K$. Using the large data samples collected by the LHCb detector, the $B\\to h^+ h^{'-}$ channels with the largest branching fractions provide an opportunity to perform high-precisi