WorldWideScience

Sample records for parsimony on-line measurement

  1. Maximum Parsimony on Phylogenetic networks

    Science.gov (United States)

    2012-01-01

    Background Phylogenetic networks are generalizations of phylogenetic trees, that are used to model evolutionary events in various contexts. Several different methods and criteria have been introduced for reconstructing phylogenetic trees. Maximum Parsimony is a character-based approach that infers a phylogenetic tree by minimizing the total number of evolutionary steps required to explain a given set of data assigned on the leaves. Exact solutions for optimizing parsimony scores on phylogenetic trees have been introduced in the past. Results In this paper, we define the parsimony score on networks as the sum of the substitution costs along all the edges of the network; and show that certain well-known algorithms that calculate the optimum parsimony score on trees, such as Sankoff and Fitch algorithms extend naturally for networks, barring conflicting assignments at the reticulate vertices. We provide heuristics for finding the optimum parsimony scores on networks. Our algorithms can be applied for any cost matrix that may contain unequal substitution costs of transforming between different characters along different edges of the network. We analyzed this for experimental data on 10 leaves or fewer with at most 2 reticulations and found that for almost all networks, the bounds returned by the heuristics matched with the exhaustively determined optimum parsimony scores. Conclusion The parsimony score we define here does not directly reflect the cost of the best tree in the network that displays the evolution of the character. However, when searching for the most parsimonious network that describes a collection of characters, it becomes necessary to add additional cost considerations to prefer simpler structures, such as trees over networks. The parsimony score on a network that we describe here takes into account the substitution costs along the additional edges incident on each reticulate vertex, in addition to the substitution costs along the other edges which are

  2. On the quirks of maximum parsimony and likelihood on phylogenetic networks.

    Science.gov (United States)

    Bryant, Christopher; Fischer, Mareike; Linz, Simone; Semple, Charles

    2017-03-21

    Maximum parsimony is one of the most frequently-discussed tree reconstruction methods in phylogenetic estimation. However, in recent years it has become more and more apparent that phylogenetic trees are often not sufficient to describe evolution accurately. For instance, processes like hybridization or lateral gene transfer that are commonplace in many groups of organisms and result in mosaic patterns of relationships cannot be represented by a single phylogenetic tree. This is why phylogenetic networks, which can display such events, are becoming of more and more interest in phylogenetic research. It is therefore necessary to extend concepts like maximum parsimony from phylogenetic trees to networks. Several suggestions for possible extensions can be found in recent literature, for instance the softwired and the hardwired parsimony concepts. In this paper, we analyze the so-called big parsimony problem under these two concepts, i.e. we investigate maximum parsimonious networks and analyze their properties. In particular, we show that finding a softwired maximum parsimony network is possible in polynomial time. We also show that the set of maximum parsimony networks for the hardwired definition always contains at least one phylogenetic tree. Lastly, we investigate some parallels of parsimony to different likelihood concepts on phylogenetic networks. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. More quality measures versus measuring what matters: a call for balance and parsimony.

    Science.gov (United States)

    Meyer, Gregg S; Nelson, Eugene C; Pryor, David B; James, Brent; Swensen, Stephen J; Kaplan, Gary S; Weissberg, Jed I; Bisognano, Maureen; Yates, Gary R; Hunt, Gordon C

    2012-11-01

    External groups requiring measures now include public and private payers, regulators, accreditors and others that certify performance levels for consumers, patients and payers. Although benefits have accrued from the growth in quality measurement, the recent explosion in the number of measures threatens to shift resources from improving quality to cover a plethora of quality-performance metrics that may have a limited impact on the things that patients and payers want and need (ie, better outcomes, better care, and lower per capita costs). Here we propose a policy that quality measurement should be: balanced to meet the need of end users to judge quality and cost performance and the need of providers to continuously improve the quality, outcomes and costs of their services; and parsimonious to measure quality, outcomes and costs with appropriate metrics that are selected based on end-user needs.

  4. Parsimonious Refraction Interferometry and Tomography

    KAUST Repository

    Hanafy, Sherif

    2017-02-04

    We present parsimonious refraction interferometry and tomography where a densely populated refraction data set can be obtained from two reciprocal and several infill shot gathers. The assumptions are that the refraction arrivals are head waves, and a pair of reciprocal shot gathers and several infill shot gathers are recorded over the line of interest. Refraction traveltimes from these shot gathers are picked and spawned into O(N2) virtual refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. The virtual traveltimes can be inverted to give the velocity tomogram. This enormous increase in the number of traveltime picks and associated rays, compared to the many fewer traveltimes from the reciprocal and infill shot gathers, allows for increased model resolution and a better condition number with the system of normal equations. A significant benefit is that the parsimonious survey and the associated traveltime picking is far less time consuming than that for a standard refraction survey with a dense distribution of sources.

  5. Parsimonious wave-equation travel-time inversion for refraction waves

    KAUST Repository

    Fu, Lei

    2017-02-14

    We present a parsimonious wave-equation travel-time inversion technique for refraction waves. A dense virtual refraction dataset can be generated from just two reciprocal shot gathers for the sources at the endpoints of the survey line, with N geophones evenly deployed along the line. These two reciprocal shots contain approximately 2N refraction travel times, which can be spawned into O(N2) refraction travel times by an interferometric transformation. Then, these virtual refraction travel times are used with a source wavelet to create N virtual refraction shot gathers, which are the input data for wave-equation travel-time inversion. Numerical results show that the parsimonious wave-equation travel-time tomogram has about the same accuracy as the tomogram computed by standard wave-equation travel-time inversion. The most significant benefit is that a reciprocal survey is far less time consuming than the standard refraction survey where a source is excited at each geophone location.

  6. Parsimonious relevance models

    NARCIS (Netherlands)

    Meij, E.; Weerkamp, W.; Balog, K.; de Rijke, M.; Myang, S.-H.; Oard, D.W.; Sebastiani, F.; Chua, T.-S.; Leong, M.-K.

    2008-01-01

    We describe a method for applying parsimonious language models to re-estimate the term probabilities assigned by relevance models. We apply our method to six topic sets from test collections in five different genres. Our parsimonious relevance models (i) improve retrieval effectiveness in terms of

  7. Parsimonious wave-equation travel-time inversion for refraction waves

    KAUST Repository

    Fu, Lei; Hanafy, Sherif M.; Schuster, Gerard T.

    2017-01-01

    We present a parsimonious wave-equation travel-time inversion technique for refraction waves. A dense virtual refraction dataset can be generated from just two reciprocal shot gathers for the sources at the endpoints of the survey line, with N

  8. Maximum parsimony on subsets of taxa.

    Science.gov (United States)

    Fischer, Mareike; Thatte, Bhalchandra D

    2009-09-21

    In this paper we investigate mathematical questions concerning the reliability (reconstruction accuracy) of Fitch's maximum parsimony algorithm for reconstructing the ancestral state given a phylogenetic tree and a character. In particular, we consider the question whether the maximum parsimony method applied to a subset of taxa can reconstruct the ancestral state of the root more accurately than when applied to all taxa, and we give an example showing that this indeed is possible. A surprising feature of our example is that ignoring a taxon closer to the root improves the reliability of the method. On the other hand, in the case of the two-state symmetric substitution model, we answer affirmatively a conjecture of Li, Steel and Zhang which states that under a molecular clock the probability that the state at a single taxon is a correct guess of the ancestral state is a lower bound on the reconstruction accuracy of Fitch's method applied to all taxa.

  9. Parsimonious refraction interferometry

    KAUST Repository

    Hanafy, Sherif

    2016-09-06

    We present parsimonious refraction interferometry where a densely populated refraction data set can be obtained from just two shot gathers. The assumptions are that the first arrivals are comprised of head waves and direct waves, and a pair of reciprocal shot gathers is recorded over the line of interest. The refraction traveltimes from these reciprocal shot gathers can be picked and decomposed into O(N2) refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. This enormous increase in the number of virtual traveltime picks and associated rays, compared to the 2N traveltimes from the two reciprocal shot gathers, allows for increased model resolution and better condition numbers in the normal equations. Also, a reciprocal survey is far less time consuming than a standard refraction survey with a dense distribution of sources.

  10. Parsimonious refraction interferometry

    KAUST Repository

    Hanafy, Sherif; Schuster, Gerard T.

    2016-01-01

    We present parsimonious refraction interferometry where a densely populated refraction data set can be obtained from just two shot gathers. The assumptions are that the first arrivals are comprised of head waves and direct waves, and a pair of reciprocal shot gathers is recorded over the line of interest. The refraction traveltimes from these reciprocal shot gathers can be picked and decomposed into O(N2) refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. This enormous increase in the number of virtual traveltime picks and associated rays, compared to the 2N traveltimes from the two reciprocal shot gathers, allows for increased model resolution and better condition numbers in the normal equations. Also, a reciprocal survey is far less time consuming than a standard refraction survey with a dense distribution of sources.

  11. Reconstructing phylogenetic networks using maximum parsimony.

    Science.gov (United States)

    Nakhleh, Luay; Jin, Guohua; Zhao, Fengmei; Mellor-Crummey, John

    2005-01-01

    Phylogenies - the evolutionary histories of groups of organisms - are one of the most widely used tools throughout the life sciences, as well as objects of research within systematics, evolutionary biology, epidemiology, etc. Almost every tool devised to date to reconstruct phylogenies produces trees; yet it is widely understood and accepted that trees oversimplify the evolutionary histories of many groups of organims, most prominently bacteria (because of horizontal gene transfer) and plants (because of hybrid speciation). Various methods and criteria have been introduced for phylogenetic tree reconstruction. Parsimony is one of the most widely used and studied criteria, and various accurate and efficient heuristics for reconstructing trees based on parsimony have been devised. Jotun Hein suggested a straightforward extension of the parsimony criterion to phylogenetic networks. In this paper we formalize this concept, and provide the first experimental study of the quality of parsimony as a criterion for constructing and evaluating phylogenetic networks. Our results show that, when extended to phylogenetic networks, the parsimony criterion produces promising results. In a great majority of the cases in our experiments, the parsimony criterion accurately predicts the numbers and placements of non-tree events.

  12. Dirichlet Process Parsimonious Mixtures for clustering

    OpenAIRE

    Chamroukhi, Faicel; Bartcus, Marius; Glotin, Hervé

    2015-01-01

    The parsimonious Gaussian mixture models, which exploit an eigenvalue decomposition of the group covariance matrices of the Gaussian mixture, have shown their success in particular in cluster analysis. Their estimation is in general performed by maximum likelihood estimation and has also been considered from a parametric Bayesian prospective. We propose new Dirichlet Process Parsimonious mixtures (DPPM) which represent a Bayesian nonparametric formulation of these parsimonious Gaussian mixtur...

  13. A unifying model of genome evolution under parsimony.

    Science.gov (United States)

    Paten, Benedict; Zerbino, Daniel R; Hickey, Glenn; Haussler, David

    2014-06-19

    Parsimony and maximum likelihood methods of phylogenetic tree estimation and parsimony methods for genome rearrangements are central to the study of genome evolution yet to date they have largely been pursued in isolation. We present a data structure called a history graph that offers a practical basis for the analysis of genome evolution. It conceptually simplifies the study of parsimonious evolutionary histories by representing both substitutions and double cut and join (DCJ) rearrangements in the presence of duplications. The problem of constructing parsimonious history graphs thus subsumes related maximum parsimony problems in the fields of phylogenetic reconstruction and genome rearrangement. We show that tractable functions can be used to define upper and lower bounds on the minimum number of substitutions and DCJ rearrangements needed to explain any history graph. These bounds become tight for a special type of unambiguous history graph called an ancestral variation graph (AVG), which constrains in its combinatorial structure the number of operations required. We finally demonstrate that for a given history graph G, a finite set of AVGs describe all parsimonious interpretations of G, and this set can be explored with a few sampling moves. This theoretical study describes a model in which the inference of genome rearrangements and phylogeny can be unified under parsimony.

  14. Improved Maximum Parsimony Models for Phylogenetic Networks.

    Science.gov (United States)

    Van Iersel, Leo; Jones, Mark; Scornavacca, Celine

    2018-05-01

    Phylogenetic networks are well suited to represent evolutionary histories comprising reticulate evolution. Several methods aiming at reconstructing explicit phylogenetic networks have been developed in the last two decades. In this article, we propose a new definition of maximum parsimony for phylogenetic networks that permits to model biological scenarios that cannot be modeled by the definitions currently present in the literature (namely, the "hardwired" and "softwired" parsimony). Building on this new definition, we provide several algorithmic results that lay the foundations for new parsimony-based methods for phylogenetic network reconstruction.

  15. DupTree: a program for large-scale phylogenetic analyses using gene tree parsimony.

    Science.gov (United States)

    Wehe, André; Bansal, Mukul S; Burleigh, J Gordon; Eulenstein, Oliver

    2008-07-01

    DupTree is a new software program for inferring rooted species trees from collections of gene trees using the gene tree parsimony approach. The program implements a novel algorithm that significantly improves upon the run time of standard search heuristics for gene tree parsimony, and enables the first truly genome-scale phylogenetic analyses. In addition, DupTree allows users to examine alternate rootings and to weight the reconciliation costs for gene trees. DupTree is an open source project written in C++. DupTree for Mac OS X, Windows, and Linux along with a sample dataset and an on-line manual are available at http://genome.cs.iastate.edu/CBL/DupTree

  16. Parsimonious Language Models for Information Retrieval

    NARCIS (Netherlands)

    Hiemstra, Djoerd; Robertson, Stephen; Zaragoza, Hugo

    We systematically investigate a new approach to estimating the parameters of language models for information retrieval, called parsimonious language models. Parsimonious language models explicitly address the relation between levels of language models that are typically used for smoothing. As such,

  17. MPBoot: fast phylogenetic maximum parsimony tree inference and bootstrap approximation.

    Science.gov (United States)

    Hoang, Diep Thi; Vinh, Le Sy; Flouri, Tomáš; Stamatakis, Alexandros; von Haeseler, Arndt; Minh, Bui Quang

    2018-02-02

    The nonparametric bootstrap is widely used to measure the branch support of phylogenetic trees. However, bootstrapping is computationally expensive and remains a bottleneck in phylogenetic analyses. Recently, an ultrafast bootstrap approximation (UFBoot) approach was proposed for maximum likelihood analyses. However, such an approach is still missing for maximum parsimony. To close this gap we present MPBoot, an adaptation and extension of UFBoot to compute branch supports under the maximum parsimony principle. MPBoot works for both uniform and non-uniform cost matrices. Our analyses on biological DNA and protein showed that under uniform cost matrices, MPBoot runs on average 4.7 (DNA) to 7 times (protein data) (range: 1.2-20.7) faster than the standard parsimony bootstrap implemented in PAUP*; but 1.6 (DNA) to 4.1 times (protein data) slower than the standard bootstrap with a fast search routine in TNT (fast-TNT). However, for non-uniform cost matrices MPBoot is 5 (DNA) to 13 times (protein data) (range:0.3-63.9) faster than fast-TNT. We note that MPBoot achieves better scores more frequently than PAUP* and fast-TNT. However, this effect is less pronounced if an intensive but slower search in TNT is invoked. Moreover, experiments on large-scale simulated data show that while both PAUP* and TNT bootstrap estimates are too conservative, MPBoot bootstrap estimates appear more unbiased. MPBoot provides an efficient alternative to the standard maximum parsimony bootstrap procedure. It shows favorable performance in terms of run time, the capability of finding a maximum parsimony tree, and high bootstrap accuracy on simulated as well as empirical data sets. MPBoot is easy-to-use, open-source and available at http://www.cibiv.at/software/mpboot .

  18. Time-Dependent-Asymmetric-Linear-Parsimonious Ancestral State Reconstruction.

    Science.gov (United States)

    Didier, Gilles

    2017-10-01

    The time-dependent-asymmetric-linear parsimony is an ancestral state reconstruction method which extends the standard linear parsimony (a.k.a. Wagner parsimony) approach by taking into account both branch lengths and asymmetric evolutionary costs for reconstructing quantitative characters (asymmetric costs amount to assuming an evolutionary trend toward the direction with the lowest cost). A formal study of the influence of the asymmetry parameter shows that the time-dependent-asymmetric-linear parsimony infers states which are all taken among the known states, except for some degenerate cases corresponding to special values of the asymmetry parameter. This remarkable property holds in particular for the Wagner parsimony. This study leads to a polynomial algorithm which determines, and provides a compact representation of, the parametric reconstruction of a phylogenetic tree, that is for all the unknown nodes, the set of all the possible reconstructed states associated with the asymmetry parameters leading to them. The time-dependent-asymmetric-linear parsimony is finally illustrated with the parametric reconstruction of the body size of cetaceans.

  19. Seeking parsimony in hydrology and water resources technology

    Science.gov (United States)

    Koutsoyiannis, D.

    2009-04-01

    The principle of parsimony, also known as the principle of simplicity, the principle of economy and Ockham's razor, advises scientists to prefer the simplest theory among those that fit the data equally well. In this, it is an epistemic principle but reflects an ontological characterization that the universe is ultimately parsimonious. Is this principle useful and can it really be reconciled with, and implemented to, our modelling approaches of complex hydrological systems, whose elements and events are extraordinarily numerous, different and unique? The answer underlying the mainstream hydrological research of the last two decades seems to be negative. Hopes were invested to the power of computers that would enable faithful and detailed representation of the diverse system elements and the hydrological processes, based on merely "first principles" and resulting in "physically-based" models that tend to approach in complexity the real world systems. Today the account of such research endeavour seems not positive, as it did not improve model predictive capacity and processes comprehension. A return to parsimonious modelling seems to be again the promising route. The experience from recent research and from comparisons of parsimonious and complicated models indicates that the former can facilitate insight and comprehension, improve accuracy and predictive capacity, and increase efficiency. In addition - and despite aspiration that "physically based" models will have lower data requirements and, even, they ultimately become "data-free" - parsimonious models require fewer data to achieve the same accuracy with more complicated models. Naturally, the concepts that reconcile the simplicity of parsimonious models with the complexity of hydrological systems are probability theory and statistics. Probability theory provides the theoretical basis for moving from a microscopic to a macroscopic view of phenomena, by mapping sets of diverse elements and events of hydrological

  20. Parsimonious Wavelet Kernel Extreme Learning Machine

    Directory of Open Access Journals (Sweden)

    Wang Qin

    2015-11-01

    Full Text Available In this study, a parsimonious scheme for wavelet kernel extreme learning machine (named PWKELM was introduced by combining wavelet theory and a parsimonious algorithm into kernel extreme learning machine (KELM. In the wavelet analysis, bases that were localized in time and frequency to represent various signals effectively were used. Wavelet kernel extreme learning machine (WELM maximized its capability to capture the essential features in “frequency-rich” signals. The proposed parsimonious algorithm also incorporated significant wavelet kernel functions via iteration in virtue of Householder matrix, thus producing a sparse solution that eased the computational burden and improved numerical stability. The experimental results achieved from the synthetic dataset and a gas furnace instance demonstrated that the proposed PWKELM is efficient and feasible in terms of improving generalization accuracy and real time performance.

  1. Bootstrap-based Support of HGT Inferred by Maximum Parsimony

    Directory of Open Access Journals (Sweden)

    Nakhleh Luay

    2010-05-01

    Full Text Available Abstract Background Maximum parsimony is one of the most commonly used criteria for reconstructing phylogenetic trees. Recently, Nakhleh and co-workers extended this criterion to enable reconstruction of phylogenetic networks, and demonstrated its application to detecting reticulate evolutionary relationships. However, one of the major problems with this extension has been that it favors more complex evolutionary relationships over simpler ones, thus having the potential for overestimating the amount of reticulation in the data. An ad hoc solution to this problem that has been used entails inspecting the improvement in the parsimony length as more reticulation events are added to the model, and stopping when the improvement is below a certain threshold. Results In this paper, we address this problem in a more systematic way, by proposing a nonparametric bootstrap-based measure of support of inferred reticulation events, and using it to determine the number of those events, as well as their placements. A number of samples is generated from the given sequence alignment, and reticulation events are inferred based on each sample. Finally, the support of each reticulation event is quantified based on the inferences made over all samples. Conclusions We have implemented our method in the NEPAL software tool (available publicly at http://bioinfo.cs.rice.edu/, and studied its performance on both biological and simulated data sets. While our studies show very promising results, they also highlight issues that are inherently challenging when applying the maximum parsimony criterion to detect reticulate evolution.

  2. Bootstrap-based support of HGT inferred by maximum parsimony.

    Science.gov (United States)

    Park, Hyun Jung; Jin, Guohua; Nakhleh, Luay

    2010-05-05

    Maximum parsimony is one of the most commonly used criteria for reconstructing phylogenetic trees. Recently, Nakhleh and co-workers extended this criterion to enable reconstruction of phylogenetic networks, and demonstrated its application to detecting reticulate evolutionary relationships. However, one of the major problems with this extension has been that it favors more complex evolutionary relationships over simpler ones, thus having the potential for overestimating the amount of reticulation in the data. An ad hoc solution to this problem that has been used entails inspecting the improvement in the parsimony length as more reticulation events are added to the model, and stopping when the improvement is below a certain threshold. In this paper, we address this problem in a more systematic way, by proposing a nonparametric bootstrap-based measure of support of inferred reticulation events, and using it to determine the number of those events, as well as their placements. A number of samples is generated from the given sequence alignment, and reticulation events are inferred based on each sample. Finally, the support of each reticulation event is quantified based on the inferences made over all samples. We have implemented our method in the NEPAL software tool (available publicly at http://bioinfo.cs.rice.edu/), and studied its performance on both biological and simulated data sets. While our studies show very promising results, they also highlight issues that are inherently challenging when applying the maximum parsimony criterion to detect reticulate evolution.

  3. Quality Quandaries- Time Series Model Selection and Parsimony

    DEFF Research Database (Denmark)

    Bisgaard, Søren; Kulahci, Murat

    2009-01-01

    Some of the issues involved in selecting adequate models for time series data are discussed using an example concerning the number of users of an Internet server. The process of selecting an appropriate model is subjective and requires experience and judgment. The authors believe an important...... consideration in model selection should be parameter parsimony. They favor the use of parsimonious mixed ARMA models, noting that research has shown that a model building strategy that considers only autoregressive representations will lead to non-parsimonious models and to loss of forecasting accuracy....

  4. Parsimonious Surface Wave Interferometry

    KAUST Repository

    Li, Jing

    2017-10-24

    To decrease the recording time of a 2D seismic survey from a few days to one hour or less, we present a parsimonious surface-wave interferometry method. Interferometry allows for the creation of a large number of virtual shot gathers from just two reciprocal shot gathers by crosscoherence of trace pairs, where the virtual surface waves can be inverted for the S-wave velocity model by wave-equation dispersion inversion (WD). Synthetic and field data tests suggest that parsimonious wave-equation dispersion inversion (PWD) gives S-velocity tomograms that are comparable to those obtained from a full survey with a shot at each receiver. The limitation of PWD is that the virtual data lose some information so that the resolution of the S-velocity tomogram can be modestly lower than that of the S-velocity tomogram inverted from a conventional survey.

  5. Parsimonious Surface Wave Interferometry

    KAUST Repository

    Li, Jing; Hanafy, Sherif; Schuster, Gerard T.

    2017-01-01

    To decrease the recording time of a 2D seismic survey from a few days to one hour or less, we present a parsimonious surface-wave interferometry method. Interferometry allows for the creation of a large number of virtual shot gathers from just two reciprocal shot gathers by crosscoherence of trace pairs, where the virtual surface waves can be inverted for the S-wave velocity model by wave-equation dispersion inversion (WD). Synthetic and field data tests suggest that parsimonious wave-equation dispersion inversion (PWD) gives S-velocity tomograms that are comparable to those obtained from a full survey with a shot at each receiver. The limitation of PWD is that the virtual data lose some information so that the resolution of the S-velocity tomogram can be modestly lower than that of the S-velocity tomogram inverted from a conventional survey.

  6. Direct maximum parsimony phylogeny reconstruction from genotype data.

    Science.gov (United States)

    Sridhar, Srinath; Lam, Fumei; Blelloch, Guy E; Ravi, R; Schwartz, Russell

    2007-12-05

    Maximum parsimony phylogenetic tree reconstruction from genetic variation data is a fundamental problem in computational genetics with many practical applications in population genetics, whole genome analysis, and the search for genetic predictors of disease. Efficient methods are available for reconstruction of maximum parsimony trees from haplotype data, but such data are difficult to determine directly for autosomal DNA. Data more commonly is available in the form of genotypes, which consist of conflated combinations of pairs of haplotypes from homologous chromosomes. Currently, there are no general algorithms for the direct reconstruction of maximum parsimony phylogenies from genotype data. Hence phylogenetic applications for autosomal data must therefore rely on other methods for first computationally inferring haplotypes from genotypes. In this work, we develop the first practical method for computing maximum parsimony phylogenies directly from genotype data. We show that the standard practice of first inferring haplotypes from genotypes and then reconstructing a phylogeny on the haplotypes often substantially overestimates phylogeny size. As an immediate application, our method can be used to determine the minimum number of mutations required to explain a given set of observed genotypes. Phylogeny reconstruction directly from unphased data is computationally feasible for moderate-sized problem instances and can lead to substantially more accurate tree size inferences than the standard practice of treating phasing and phylogeny construction as two separate analysis stages. The difference between the approaches is particularly important for downstream applications that require a lower-bound on the number of mutations that the genetic region has undergone.

  7. Direct maximum parsimony phylogeny reconstruction from genotype data

    Directory of Open Access Journals (Sweden)

    Ravi R

    2007-12-01

    Full Text Available Abstract Background Maximum parsimony phylogenetic tree reconstruction from genetic variation data is a fundamental problem in computational genetics with many practical applications in population genetics, whole genome analysis, and the search for genetic predictors of disease. Efficient methods are available for reconstruction of maximum parsimony trees from haplotype data, but such data are difficult to determine directly for autosomal DNA. Data more commonly is available in the form of genotypes, which consist of conflated combinations of pairs of haplotypes from homologous chromosomes. Currently, there are no general algorithms for the direct reconstruction of maximum parsimony phylogenies from genotype data. Hence phylogenetic applications for autosomal data must therefore rely on other methods for first computationally inferring haplotypes from genotypes. Results In this work, we develop the first practical method for computing maximum parsimony phylogenies directly from genotype data. We show that the standard practice of first inferring haplotypes from genotypes and then reconstructing a phylogeny on the haplotypes often substantially overestimates phylogeny size. As an immediate application, our method can be used to determine the minimum number of mutations required to explain a given set of observed genotypes. Conclusion Phylogeny reconstruction directly from unphased data is computationally feasible for moderate-sized problem instances and can lead to substantially more accurate tree size inferences than the standard practice of treating phasing and phylogeny construction as two separate analysis stages. The difference between the approaches is particularly important for downstream applications that require a lower-bound on the number of mutations that the genetic region has undergone.

  8. Parsimonious Refraction Interferometry and Tomography

    KAUST Repository

    Hanafy, Sherif; Schuster, Gerard T.

    2017-01-01

    We present parsimonious refraction interferometry and tomography where a densely populated refraction data set can be obtained from two reciprocal and several infill shot gathers. The assumptions are that the refraction arrivals are head waves

  9. Direct maximum parsimony phylogeny reconstruction from genotype data

    OpenAIRE

    Sridhar, Srinath; Lam, Fumei; Blelloch, Guy E; Ravi, R; Schwartz, Russell

    2007-01-01

    Abstract Background Maximum parsimony phylogenetic tree reconstruction from genetic variation data is a fundamental problem in computational genetics with many practical applications in population genetics, whole genome analysis, and the search for genetic predictors of disease. Efficient methods are available for reconstruction of maximum parsimony trees from haplotype data, but such data are difficult to determine directly for autosomal DNA. Data more commonly is available in the form of ge...

  10. Failed refutations: further comments on parsimony and likelihood methods and their relationship to Popper's degree of corroboration.

    Science.gov (United States)

    de Queiroz, Kevin; Poe, Steven

    2003-06-01

    Kluge's (2001, Syst. Biol. 50:322-330) continued arguments that phylogenetic methods based on the statistical principle of likelihood are incompatible with the philosophy of science described by Karl Popper are based on false premises related to Kluge's misrepresentations of Popper's philosophy. Contrary to Kluge's conjectures, likelihood methods are not inherently verificationist; they do not treat every instance of a hypothesis as confirmation of that hypothesis. The historical nature of phylogeny does not preclude phylogenetic hypotheses from being evaluated using the probability of evidence. The low absolute probabilities of hypotheses are irrelevant to the correct interpretation of Popper's concept termed degree of corroboration, which is defined entirely in terms of relative probabilities. Popper did not advocate minimizing background knowledge; in any case, the background knowledge of both parsimony and likelihood methods consists of the general assumption of descent with modification and additional assumptions that are deterministic, concerning which tree is considered most highly corroborated. Although parsimony methods do not assume (in the sense of entailing) that homoplasy is rare, they do assume (in the sense of requiring to obtain a correct phylogenetic inference) certain things about patterns of homoplasy. Both parsimony and likelihood methods assume (in the sense of implying by the manner in which they operate) various things about evolutionary processes, although violation of those assumptions does not always cause the methods to yield incorrect phylogenetic inferences. Test severity is increased by sampling additional relevant characters rather than by character reanalysis, although either interpretation is compatible with the use of phylogenetic likelihood methods. Neither parsimony nor likelihood methods assess test severity (critical evidence) when used to identify a most highly corroborated tree(s) based on a single method or model and a

  11. On-Line Voltage Stability Assessment based on PMU Measurements

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; P. Da Silva, Luiz C.; Nielsen, Arne Hejde

    2009-01-01

    This paper presents a method for on-line monitoring of risk voltage collapse based on synchronised phasor measurement. As there is no room for intensive computation and analysis in real-time, the method is based on the combination of off-line computation and on-line monitoring, which are correlat...

  12. Fast Construction of Near Parsimonious Hybridization Networks for Multiple Phylogenetic Trees.

    Science.gov (United States)

    Mirzaei, Sajad; Wu, Yufeng

    2016-01-01

    Hybridization networks represent plausible evolutionary histories of species that are affected by reticulate evolutionary processes. An established computational problem on hybridization networks is constructing the most parsimonious hybridization network such that each of the given phylogenetic trees (called gene trees) is "displayed" in the network. There have been several previous approaches, including an exact method and several heuristics, for this NP-hard problem. However, the exact method is only applicable to a limited range of data, and heuristic methods can be less accurate and also slow sometimes. In this paper, we develop a new algorithm for constructing near parsimonious networks for multiple binary gene trees. This method is more efficient for large numbers of gene trees than previous heuristics. This new method also produces more parsimonious results on many simulated datasets as well as a real biological dataset than a previous method. We also show that our method produces topologically more accurate networks for many datasets.

  13. Efficient parsimony-based methods for phylogenetic network reconstruction.

    Science.gov (United States)

    Jin, Guohua; Nakhleh, Luay; Snir, Sagi; Tuller, Tamir

    2007-01-15

    Phylogenies--the evolutionary histories of groups of organisms-play a major role in representing relationships among biological entities. Although many biological processes can be effectively modeled as tree-like relationships, others, such as hybrid speciation and horizontal gene transfer (HGT), result in networks, rather than trees, of relationships. Hybrid speciation is a significant evolutionary mechanism in plants, fish and other groups of species. HGT plays a major role in bacterial genome diversification and is a significant mechanism by which bacteria develop resistance to antibiotics. Maximum parsimony is one of the most commonly used criteria for phylogenetic tree inference. Roughly speaking, inference based on this criterion seeks the tree that minimizes the amount of evolution. In 1990, Jotun Hein proposed using this criterion for inferring the evolution of sequences subject to recombination. Preliminary results on small synthetic datasets. Nakhleh et al. (2005) demonstrated the criterion's application to phylogenetic network reconstruction in general and HGT detection in particular. However, the naive algorithms used by the authors are inapplicable to large datasets due to their demanding computational requirements. Further, no rigorous theoretical analysis of computing the criterion was given, nor was it tested on biological data. In the present work we prove that the problem of scoring the parsimony of a phylogenetic network is NP-hard and provide an improved fixed parameter tractable algorithm for it. Further, we devise efficient heuristics for parsimony-based reconstruction of phylogenetic networks. We test our methods on both synthetic and biological data (rbcL gene in bacteria) and obtain very promising results.

  14. On the Quirks of Maximum Parsimony and Likelihood on Phylogenetic Networks

    OpenAIRE

    Bryant, Christopher; Fischer, Mareike; Linz, Simone; Semple, Charles

    2015-01-01

    Maximum parsimony is one of the most frequently-discussed tree reconstruction methods in phylogenetic estimation. However, in recent years it has become more and more apparent that phylogenetic trees are often not sufficient to describe evolution accurately. For instance, processes like hybridization or lateral gene transfer that are commonplace in many groups of organisms and result in mosaic patterns of relationships cannot be represented by a single phylogenetic tree. This is why phylogene...

  15. The worst case complexity of maximum parsimony.

    Science.gov (United States)

    Carmel, Amir; Musa-Lempel, Noa; Tsur, Dekel; Ziv-Ukelson, Michal

    2014-11-01

    One of the core classical problems in computational biology is that of constructing the most parsimonious phylogenetic tree interpreting an input set of sequences from the genomes of evolutionarily related organisms. We reexamine the classical maximum parsimony (MP) optimization problem for the general (asymmetric) scoring matrix case, where rooted phylogenies are implied, and analyze the worst case bounds of three approaches to MP: The approach of Cavalli-Sforza and Edwards, the approach of Hendy and Penny, and a new agglomerative, "bottom-up" approach we present in this article. We show that the second and third approaches are faster than the first one by a factor of Θ(√n) and Θ(n), respectively, where n is the number of species.

  16. Philosophy and phylogenetic inference: a comparison of likelihood and parsimony methods in the context of Karl Popper's writings on corroboration.

    Science.gov (United States)

    de Queiroz, K; Poe, S

    2001-06-01

    Advocates of cladistic parsimony methods have invoked the philosophy of Karl Popper in an attempt to argue for the superiority of those methods over phylogenetic methods based on Ronald Fisher's statistical principle of likelihood. We argue that the concept of likelihood in general, and its application to problems of phylogenetic inference in particular, are highly compatible with Popper's philosophy. Examination of Popper's writings reveals that his concept of corroboration is, in fact, based on likelihood. Moreover, because probabilistic assumptions are necessary for calculating the probabilities that define Popper's corroboration, likelihood methods of phylogenetic inference--with their explicit probabilistic basis--are easily reconciled with his concept. In contrast, cladistic parsimony methods, at least as described by certain advocates of those methods, are less easily reconciled with Popper's concept of corroboration. If those methods are interpreted as lacking probabilistic assumptions, then they are incompatible with corroboration. Conversely, if parsimony methods are to be considered compatible with corroboration, then they must be interpreted as carrying implicit probabilistic assumptions. Thus, the non-probabilistic interpretation of cladistic parsimony favored by some advocates of those methods is contradicted by an attempt by the same authors to justify parsimony methods in terms of Popper's concept of corroboration. In addition to being compatible with Popperian corroboration, the likelihood approach to phylogenetic inference permits researchers to test the assumptions of their analytical methods (models) in a way that is consistent with Popper's ideas about the provisional nature of background knowledge.

  17. Hypothesis of the Disappearance of the Limits of Improvidence and Parsimony in the Function of Consumption in an Islamic Economy

    Directory of Open Access Journals (Sweden)

    محمد أحمد حسن الأفندي

    2018-04-01

    Full Text Available There is a rich literature about the analysis of consumption behavior from the perspective of Islamic economy. The focus of such literature has been on the incorporation of the effect of moral values on individuals’ consumption behavior. However, studies on consumption did not pay enough heed to the analysis of the ultimate effect of faith values on the track of consumption behavior over time. This desired track of consumption involves showing certain hypotheses and probabilities. This study suggests a normative statement which includes the gradual disappearance of parsimony and improvidence over time. This disappearance would correct the deviation of actual consumption of society members from the desired moderate consumption level, so as to make households’ consumption behavior at the desired level which is consistent with Islamic Sharia. The study emphasizes the need to develop analysis and research in two integrated directions: i conducting more empirical studies to examine the consistency of the normative statement with evidence from real situations, and ii conducting more analysis to develop a specific measure for the desired consumption levels as well as the limits of parsimony and improvidence. Keywords: Disappearance of improvidence and parsimony limits, Desired moderate consumption level, Actual consumption, Improvidence and parsimony consumption levels, Track of households’ consumption behavior.

  18. Ancestral sequence reconstruction with Maximum Parsimony

    OpenAIRE

    Herbst, Lina; Fischer, Mareike

    2017-01-01

    One of the main aims in phylogenetics is the estimation of ancestral sequences based on present-day data like, for instance, DNA alignments. One way to estimate the data of the last common ancestor of a given set of species is to first reconstruct a phylogenetic tree with some tree inference method and then to use some method of ancestral state inference based on that tree. One of the best-known methods both for tree inference as well as for ancestral sequence inference is Maximum Parsimony (...

  19. Quality Assurance Based on Descriptive and Parsimonious Appearance Models

    DEFF Research Database (Denmark)

    Nielsen, Jannik Boll; Eiríksson, Eyþór Rúnar; Kristensen, Rasmus Lyngby

    2015-01-01

    In this positional paper, we discuss the potential benefits of using appearance models in additive manufacturing, metal casting, wind turbine blade production, and 3D content acquisition. Current state of the art in acquisition and rendering of appearance cannot easily be used for quality assurance...... in these areas. The common denominator is the need for descriptive and parsimonious appearance models. By ‘parsimonious’ we mean with few parameters so that a model is useful both for fast acquisition, robust fitting, and fast rendering of appearance. The word ‘descriptive’ refers to the fact that a model should...

  20. Beyond technology acceptance to effective technology use: a parsimonious and actionable model.

    Science.gov (United States)

    Holahan, Patricia J; Lesselroth, Blake J; Adams, Kathleen; Wang, Kai; Church, Victoria

    2015-05-01

    To develop and test a parsimonious and actionable model of effective technology use (ETU). Cross-sectional survey of primary care providers (n = 53) in a large integrated health care organization that recently implemented new medication reconciliation technology. Surveys assessed 5 technology-related perceptions (compatibility with work values, implementation climate, compatibility with work processes, perceived usefulness, and ease of use) and 1 outcome variable, ETU. ETU was measured as both consistency and quality of technology use. Compatibility with work values and implementation climate were found to have differential effects on consistency and quality of use. When implementation climate was strong, consistency of technology use was high. However, quality of technology use was high only when implementation climate was strong and values compatibility was high. This is an important finding and highlights the importance of users' workplace values as a key determinant of quality of use. To extend our effectiveness in implementing new health care information technology, we need parsimonious models that include actionable determinants of ETU and account for the differential effects of these determinants on the multiple dimensions of ETU. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Local high precision 3D measurement based on line laser measuring instrument

    Science.gov (United States)

    Zhang, Renwei; Liu, Wei; Lu, Yongkang; Zhang, Yang; Ma, Jianwei; Jia, Zhenyuan

    2018-03-01

    In order to realize the precision machining and assembly of the parts, the geometrical dimensions of the surface of the local assembly surfaces need to be strictly guaranteed. In this paper, a local high-precision three-dimensional measurement method based on line laser measuring instrument is proposed to achieve a high degree of accuracy of the three-dimensional reconstruction of the surface. Aiming at the problem of two-dimensional line laser measuring instrument which lacks one-dimensional high-precision information, a local three-dimensional profile measuring system based on an accurate single-axis controller is proposed. First of all, a three-dimensional data compensation method based on spatial multi-angle line laser measuring instrument is proposed to achieve the high-precision measurement of the default axis. Through the pretreatment of the 3D point cloud information, the measurement points can be restored accurately. Finally, the target spherical surface is needed to make local three-dimensional scanning measurements for accuracy verification. The experimental results show that this scheme can get the local three-dimensional information of the target quickly and accurately, and achieves the purpose of gaining the information and compensating the error for laser scanner information, and improves the local measurement accuracy.

  2. Things fall apart: biological species form unconnected parsimony networks.

    Science.gov (United States)

    Hart, Michael W; Sunday, Jennifer

    2007-10-22

    The generality of operational species definitions is limited by problematic definitions of between-species divergence. A recent phylogenetic species concept based on a simple objective measure of statistically significant genetic differentiation uses between-species application of statistical parsimony networks that are typically used for population genetic analysis within species. Here we review recent phylogeographic studies and reanalyse several mtDNA barcoding studies using this method. We found that (i) alignments of DNA sequences typically fall apart into a separate subnetwork for each Linnean species (but with a higher rate of true positives for mtDNA data) and (ii) DNA sequences from single species typically stick together in a single haplotype network. Departures from these patterns are usually consistent with hybridization or cryptic species diversity.

  3. Live phylogeny with polytomies: Finding the most compact parsimonious trees.

    Science.gov (United States)

    Papamichail, D; Huang, A; Kennedy, E; Ott, J-L; Miller, A; Papamichail, G

    2017-08-01

    Construction of phylogenetic trees has traditionally focused on binary trees where all species appear on leaves, a problem for which numerous efficient solutions have been developed. Certain application domains though, such as viral evolution and transmission, paleontology, linguistics, and phylogenetic stemmatics, often require phylogeny inference that involves placing input species on ancestral tree nodes (live phylogeny), and polytomies. These requirements, despite their prevalence, lead to computationally harder algorithmic solutions and have been sparsely examined in the literature to date. In this article we prove some unique properties of most parsimonious live phylogenetic trees with polytomies, and their mapping to traditional binary phylogenetic trees. We show that our problem reduces to finding the most compact parsimonious tree for n species, and describe a novel efficient algorithm to find such trees without resorting to exhaustive enumeration of all possible tree topologies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. A class representative model for Pure Parsimony Haplotyping under uncertain data.

    Directory of Open Access Journals (Sweden)

    Daniele Catanzaro

    Full Text Available The Pure Parsimony Haplotyping (PPH problem is a NP-hard combinatorial optimization problem that consists of finding the minimum number of haplotypes necessary to explain a given set of genotypes. PPH has attracted more and more attention in recent years due to its importance in analysis of many fine-scale genetic data. Its application fields range from mapping complex disease genes to inferring population histories, passing through designing drugs, functional genomics and pharmacogenetics. In this article we investigate, for the first time, a recent version of PPH called the Pure Parsimony Haplotype problem under Uncertain Data (PPH-UD. This version mainly arises when the input genotypes are not accurate, i.e., when some single nucleotide polymorphisms are missing or affected by errors. We propose an exact approach to solution of PPH-UD based on an extended version of Catanzaro et al.[1] class representative model for PPH, currently the state-of-the-art integer programming model for PPH. The model is efficient, accurate, compact, polynomial-sized, easy to implement, solvable with any solver for mixed integer programming, and usable in all those cases for which the parsimony criterion is well suited for haplotype estimation.

  5. Measurement of the deuterium Balmer series line emission on EAST

    Energy Technology Data Exchange (ETDEWEB)

    Wu, C. R.; Xu, Z.; Jin, Z.; Zhang, P. F. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei, Anhui 230031 (China); Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, Anhui 230031 (China); Huang, J., E-mail: juan.huang@ipp.ac.cn; Gao, W.; Gao, W.; Chang, J. F.; Xu, J. C.; Duan, Y. M.; Chen, Y. J.; Zhang, L.; Wu, Z. W.; Li, J. G. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei, Anhui 230031 (China); Hou, Y. M. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei, Anhui 230031 (China); School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2016-11-15

    Volume recombination plays an important role towards plasma detachment for magnetically confined fusion devices. High quantum number states of the Balmer series of deuterium are used to study recombination. On EAST (Experimental Advanced Superconducting Tokamak), two visible spectroscopic measurements are applied for the upper/lower divertor with 13 channels, respectively. Both systems are coupled with Princeton Instruments ProEM EMCCD 1024B camera: one is equipped on an Acton SP2750 spectrometer, which has a high spectral resolution ∼0.0049 nm with 2400 gr/mm grating to measure the D{sub α}(H{sub α}) spectral line and with 1200 gr/mm grating to measure deuterium molecular Fulcher band emissions and another is equipped on IsoPlane SCT320 using 600 gr/mm to measure high-n Balmer series emission lines, allowing us to study volume recombination on EAST and to obtain the related line averaged plasma parameters (T{sub e}, n{sub e}) during EAST detached phases. This paper will present the details of the measurements and the characteristics of deuterium Balmer series line emissions during density ramp-up L-mode USN plasma on EAST.

  6. A simplified parsimonious higher order multivariate Markov chain model

    Science.gov (United States)

    Wang, Chao; Yang, Chuan-sheng

    2017-09-01

    In this paper, a simplified parsimonious higher-order multivariate Markov chain model (SPHOMMCM) is presented. Moreover, parameter estimation method of TPHOMMCM is give. Numerical experiments shows the effectiveness of TPHOMMCM.

  7. On-line adaptive line frequency noise cancellation from a nuclear power measuring channel

    Directory of Open Access Journals (Sweden)

    Qadir Javed

    2011-01-01

    Full Text Available On-line software for adaptively canceling 50 Hz line frequency noise has been designed and tested at Pakistan Research Reactor 1. Line frequency noise causes much problem in weak signals acquisition. Sometimes this noise is so dominant that original signal is totally corrupted. Although notch filter can be used for eliminating this noise, but if signal of interest is in close vicinity of 50 Hz, then original signal is also attenuated and hence overall performance is degraded. Adaptive noise removal is a technique which could be employed for removing line frequency without degrading the desired signal. In this paper line frequency noise has been eliminated on-line from a nuclear power measuring channel. The adaptive LMS algorithm has been used to cancel 50 Hz noise. The algorithm has been implemented in labVIEW with NI 6024 data acquisition card. The quality of the acquired signal has been improved much as can be seen in experimental results.

  8. A tridiagonal parsimonious higher order multivariate Markov chain model

    Science.gov (United States)

    Wang, Chao; Yang, Chuan-sheng

    2017-09-01

    In this paper, we present a tridiagonal parsimonious higher-order multivariate Markov chain model (TPHOMMCM). Moreover, estimation method of the parameters in TPHOMMCM is give. Numerical experiments illustrate the effectiveness of TPHOMMCM.

  9. Measurements of weak conversion lines

    International Nuclear Information System (INIS)

    Feoktistov, A.I.; Frantsev, Yu.E.

    1979-01-01

    Described is a new methods for measuring weak conversion lines with the help of the β spectrometer of the π √ 2 type which permits to increase the reliability of the results obtained. According to this method the measurements were carried out by short series with the storage of the information obtained on the punched tape. The spectrometer magnetic field was stabilized during the measuring of the conversion spectra with the help of three nmr recorders. Instead of the dependence of the pulse calculation rate on the magnetic field value was measured the dependence of the calculation rate on the value of the voltage applied between the source and the spectrometer chamber. A short description of the automatic set-up for measuring conversion lines according to the method proposed is given. The main set-up elements are the voltage multiplexer timer, printer, scaler and the pulse analyzer. With the help of the above methods obtained is the K 1035, 8 keV 182 Ta line. It is obtained as a result of the composition of 96 measurement series. Each measurement time constitutes 640 s 12 points are taken on the line

  10. On-line stable isotope measurements during plant and soil gas exchange

    International Nuclear Information System (INIS)

    Yakir, D.

    2001-01-01

    Recent techniques for on-line stable isotope measurements during plant and soil exchange of CO 2 and/or water vapor are briefly reviewed. For CO 2 , these techniques provide means for on-line measurements of isotopic discrimination during CO 2 exchange by leaves in the laboratory and in the field, of isotopic discrimination during soil respiration and during soil-atmosphere CO 2 exchange, and of isotopic discrimination in O 2 during plant respiration. For water vapor, these techniques provide means to measure oxygen isotopic composition of water vapor during leaf transpiration and for the analysis of sub microliter condensed water vapor samples. Most of these techniques involve on-line sampling of CO 2 and water vapor from a dynamic, intact soil or plant system. In the laboratory, these systems also allow on-line isotopic analysis by continuous-flow isotope ratio mass spectrometry. The information obtained with these on-line techniques is becoming increasingly valuable, and often critical, for ecophysiologial research and in the study of biosphere-atmosphere interactions. (author)

  11. Principle of Parsimony, Fake Science, and Scales

    Science.gov (United States)

    Yeh, T. C. J.; Wan, L.; Wang, X. S.

    2017-12-01

    Considering difficulties in predicting exact motions of water molecules, and the scale of our interests (bulk behaviors of many molecules), Fick's law (diffusion concept) has been created to predict solute diffusion process in space and time. G.I. Taylor (1921) demonstrated that random motion of the molecules reach the Fickian regime in less a second if our sampling scale is large enough to reach ergodic condition. Fick's law is widely accepted for describing molecular diffusion as such. This fits the definition of the parsimony principle at the scale of our concern. Similarly, advection-dispersion or convection-dispersion equation (ADE or CDE) has been found quite satisfactory for analysis of concentration breakthroughs of solute transport in uniformly packed soil columns. This is attributed to the solute is often released over the entire cross-section of the column, which has sampled many pore-scale heterogeneities and met the ergodicity assumption. Further, the uniformly packed column contains a large number of stationary pore-size heterogeneity. The solute thus reaches the Fickian regime after traveling a short distance along the column. Moreover, breakthrough curves are concentrations integrated over the column cross-section (the scale of our interest), and they meet the ergodicity assumption embedded in the ADE and CDE. To the contrary, scales of heterogeneity in most groundwater pollution problems evolve as contaminants travel. They are much larger than the scale of our observations and our interests so that the ergodic and the Fickian conditions are difficult. Upscaling the Fick's law for solution dispersion, and deriving universal rules of the dispersion to the field- or basin-scale pollution migrations are merely misuse of the parsimony principle and lead to a fake science ( i.e., the development of theories for predicting processes that can not be observed.) The appropriate principle of parsimony for these situations dictates mapping of large

  12. A Parsimonious Instrument for Predicting Students' Intent to Pursue a Sales Career: Scale Development and Validation

    Science.gov (United States)

    Peltier, James W.; Cummins, Shannon; Pomirleanu, Nadia; Cross, James; Simon, Rob

    2014-01-01

    Students' desire and intention to pursue a career in sales continue to lag behind industry demand for sales professionals. This article develops and validates a reliable and parsimonious scale for measuring and predicting student intention to pursue a selling career. The instrument advances previous scales in three ways. The instrument is…

  13. Improving integrity of on-line grammage measurement with traceable basic calibration.

    Science.gov (United States)

    Kangasrääsiö, Juha

    2010-07-01

    The automatic control of grammage (basis weight) in paper and board production is based upon on-line grammage measurement. Furthermore, the automatic control of other quality variables such as moisture, ash content and coat weight, may rely on the grammage measurement. The integrity of Kr-85 based on-line grammage measurement systems was studied, by performing basic calibrations with traceably calibrated plastic reference standards. The calibrations were performed according to the EN ISO/IEC 17025 standard, which is a requirement for calibration laboratories. The observed relative measurement errors were 3.3% in the first time calibrations at the 95% confidence level. With the traceable basic calibration method, however, these errors can be reduced to under 0.5%, thus improving the integrity of on-line grammage measurements. Also a standardised algorithm, based on the experience from the performed calibrations, is proposed to ease the adjustment of the different grammage measurement systems. The calibration technique can basically be applied to all beta-radiation based grammage measurements. 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  14. Mixed integer linear programming for maximum-parsimony phylogeny inference.

    Science.gov (United States)

    Sridhar, Srinath; Lam, Fumei; Blelloch, Guy E; Ravi, R; Schwartz, Russell

    2008-01-01

    Reconstruction of phylogenetic trees is a fundamental problem in computational biology. While excellent heuristic methods are available for many variants of this problem, new advances in phylogeny inference will be required if we are to be able to continue to make effective use of the rapidly growing stores of variation data now being gathered. In this paper, we present two integer linear programming (ILP) formulations to find the most parsimonious phylogenetic tree from a set of binary variation data. One method uses a flow-based formulation that can produce exponential numbers of variables and constraints in the worst case. The method has, however, proven extremely efficient in practice on datasets that are well beyond the reach of the available provably efficient methods, solving several large mtDNA and Y-chromosome instances within a few seconds and giving provably optimal results in times competitive with fast heuristics than cannot guarantee optimality. An alternative formulation establishes that the problem can be solved with a polynomial-sized ILP. We further present a web server developed based on the exponential-sized ILP that performs fast maximum parsimony inferences and serves as a front end to a database of precomputed phylogenies spanning the human genome.

  15. Effect of resonance line shape on precision measurements of nuclear magnetic resonance shifts

    International Nuclear Information System (INIS)

    Kachurin, A.M.; Smelyanskij, A.Ya.

    1986-01-01

    Effect of resonance line shape on the systematic error of precision measurements of nuclear magnetic resonance (NMR) shifts of high resolution (on the center of NMR dispersion line) is analysed. Effect of the device resonance line form-function asymmetry is evaluated; the form-function is determined by configuration of the spectrometer magnetic field and enters the convolution, which describes the resonance line form. It is shown that with the increase of the relaxation line width the form-function effect on the measurement error yields to zero. The form-function effect on measurements and correction of a phase angle of NMR detection is evaluated. The method of semiquantitative evaluation of resonance line and NMR spectrometer parameters, guaranteeing the systematic error of the given infinitesimal, is presented

  16. Bayesian methods outperform parsimony but at the expense of precision in the estimation of phylogeny from discrete morphological data.

    Science.gov (United States)

    O'Reilly, Joseph E; Puttick, Mark N; Parry, Luke; Tanner, Alastair R; Tarver, James E; Fleming, James; Pisani, Davide; Donoghue, Philip C J

    2016-04-01

    Different analytical methods can yield competing interpretations of evolutionary history and, currently, there is no definitive method for phylogenetic reconstruction using morphological data. Parsimony has been the primary method for analysing morphological data, but there has been a resurgence of interest in the likelihood-based Mk-model. Here, we test the performance of the Bayesian implementation of the Mk-model relative to both equal and implied-weight implementations of parsimony. Using simulated morphological data, we demonstrate that the Mk-model outperforms equal-weights parsimony in terms of topological accuracy, and implied-weights performs the most poorly. However, the Mk-model produces phylogenies that have less resolution than parsimony methods. This difference in the accuracy and precision of parsimony and Bayesian approaches to topology estimation needs to be considered when selecting a method for phylogeny reconstruction. © 2016 The Authors.

  17. Phylogenetic analysis using parsimony and likelihood methods.

    Science.gov (United States)

    Yang, Z

    1996-02-01

    The assumptions underlying the maximum-parsimony (MP) method of phylogenetic tree reconstruction were intuitively examined by studying the way the method works. Computer simulations were performed to corroborate the intuitive examination. Parsimony appears to involve very stringent assumptions concerning the process of sequence evolution, such as constancy of substitution rates between nucleotides, constancy of rates across nucleotide sites, and equal branch lengths in the tree. For practical data analysis, the requirement of equal branch lengths means similar substitution rates among lineages (the existence of an approximate molecular clock), relatively long interior branches, and also few species in the data. However, a small amount of evolution is neither a necessary nor a sufficient requirement of the method. The difficulties involved in the application of current statistical estimation theory to tree reconstruction were discussed, and it was suggested that the approach proposed by Felsenstein (1981, J. Mol. Evol. 17: 368-376) for topology estimation, as well as its many variations and extensions, differs fundamentally from the maximum likelihood estimation of a conventional statistical parameter. Evidence was presented showing that the Felsenstein approach does not share the asymptotic efficiency of the maximum likelihood estimator of a statistical parameter. Computer simulations were performed to study the probability that MP recovers the true tree under a hierarchy of models of nucleotide substitution; its performance relative to the likelihood method was especially noted. The results appeared to support the intuitive examination of the assumptions underlying MP. When a simple model of nucleotide substitution was assumed to generate data, the probability that MP recovers the true topology could be as high as, or even higher than, that for the likelihood method. When the assumed model became more complex and realistic, e.g., when substitution rates were

  18. On-line measurement of mechanical, optical properties and roughness parameters

    Directory of Open Access Journals (Sweden)

    Hartman, H.

    2005-12-01

    Full Text Available On-line measurements become a central importance for the control of production line output. The target is to replace traditional single local destructive quality checks by a continuous survey of the product properties. Other traditional like pyrometric temperature measurements suffer of well-known but non-soluble weakness points. New methods need the unambiguous correlation with the results of traditional testing to be representative for valid proof standards.EKO Stahl GmbH introduces several methods of on-line measurements focused actually on temperature measurement means of FTIR-Spectrometer, prediction of the mechanical properties of steel strips using the information of residual magnetization after a magnetization pulse and optical roughness measurements. The correlation between the results of the new methods and the classical proof processes has been established in a satisfactory manner.

    Las medidas on line van tomando una importancia central para el control de la calidad de la producción . El objetivo es reemplazar las pruebas destructivas puntuales tradicionales por un control continuo de las características del producto. Otros métodos tradicionales, como la medida de la temperatura con pirómetros, adolecen de conocidos pero insolubles puntos débiles. Los nuevos métodos necesitan la correlación inequívoca con los resultados de los métodos corrientes clásicos para obtener la autoridad de un estándar de prueba. La EKO Stahl GmbH ha introducido varios métodos de medidas on line y actualmente concentrados en la medida de la temperatura con espectrómetro FTIR, predicción de las características mecánicas usando la información del magnetismo residual, a partir de un impulso magnético inicial así como la medida óptica de la rugosidad. La correlación entre los resultados de los nuevos métodos y los métodos clásicos ha quedado establecida de manera satisfactoria.

  19. An apparatus for on-line measuring of the coating weight on art paper

    International Nuclear Information System (INIS)

    Huang Meifen; Mao Shunjuan

    1986-01-01

    The method and apparatus for on-line measuring of the coating weight on art paper are described. The design of the coating gauge was based on the technique of charcateristic X-ray fluorescence preferential absorption. The gauge was equipped with a TP-801 micro-computer which makes the gauge capable of showing and typing the data in different forms. The measurement is quick, continuous, accurate and non-destructive. Analysis period is 10 seconds. In on-line measuring, the reproducibility is +- 1 g/m 2 and the relative error of this method amounts to +- 5% with the weighing method as a standard

  20. The plunge in German electricity futures prices – Analysis using a parsimonious fundamental model

    International Nuclear Information System (INIS)

    Kallabis, Thomas; Pape, Christian; Weber, Christoph

    2016-01-01

    The German market has seen a plunge in wholesale electricity prices from 2007 until 2014, with base futures prices dropping by more than 40%. This is frequently attributed to the unexpected high increase in renewable power generation. Using a parsimonious fundamental model, we determine the respective impact of supply and demand shocks on electricity futures prices. The used methodology is based on a piecewise linear approximation of the supply stack and time-varying price-inelastic demand. This parsimonious model is able to replicate electricity futures prices and discover non-linear dependencies in futures price formation. We show that emission prices have a higher impact on power prices than renewable penetration. Changes in renewables, demand and installed capacities turn out to be similarly important for explaining the decrease in operation margins of conventional power plants. We thus argue for the establishment of an independent authority to stabilize emission prices. - Highlights: •We build a parsimonious fundamental model based on a piecewise linear bid stack. •We use the model to investigate impact factors for the plunge in German futures prices. •Largest impact by CO_2 price developments followed by demand and renewable feed-in. •Power plant operating profits strongly affected by demand and renewables. •We argue that stabilizing CO_2 emission prices could provide better market signals.

  1. PTree: pattern-based, stochastic search for maximum parsimony phylogenies

    Directory of Open Access Journals (Sweden)

    Ivan Gregor

    2013-06-01

    Full Text Available Phylogenetic reconstruction is vital to analyzing the evolutionary relationship of genes within and across populations of different species. Nowadays, with next generation sequencing technologies producing sets comprising thousands of sequences, robust identification of the tree topology, which is optimal according to standard criteria such as maximum parsimony, maximum likelihood or posterior probability, with phylogenetic inference methods is a computationally very demanding task. Here, we describe a stochastic search method for a maximum parsimony tree, implemented in a software package we named PTree. Our method is based on a new pattern-based technique that enables us to infer intermediate sequences efficiently where the incorporation of these sequences in the current tree topology yields a phylogenetic tree with a lower cost. Evaluation across multiple datasets showed that our method is comparable to the algorithms implemented in PAUP* or TNT, which are widely used by the bioinformatics community, in terms of topological accuracy and runtime. We show that our method can process large-scale datasets of 1,000–8,000 sequences. We believe that our novel pattern-based method enriches the current set of tools and methods for phylogenetic tree inference. The software is available under: http://algbio.cs.uni-duesseldorf.de/webapps/wa-download/.

  2. PTree: pattern-based, stochastic search for maximum parsimony phylogenies.

    Science.gov (United States)

    Gregor, Ivan; Steinbrück, Lars; McHardy, Alice C

    2013-01-01

    Phylogenetic reconstruction is vital to analyzing the evolutionary relationship of genes within and across populations of different species. Nowadays, with next generation sequencing technologies producing sets comprising thousands of sequences, robust identification of the tree topology, which is optimal according to standard criteria such as maximum parsimony, maximum likelihood or posterior probability, with phylogenetic inference methods is a computationally very demanding task. Here, we describe a stochastic search method for a maximum parsimony tree, implemented in a software package we named PTree. Our method is based on a new pattern-based technique that enables us to infer intermediate sequences efficiently where the incorporation of these sequences in the current tree topology yields a phylogenetic tree with a lower cost. Evaluation across multiple datasets showed that our method is comparable to the algorithms implemented in PAUP* or TNT, which are widely used by the bioinformatics community, in terms of topological accuracy and runtime. We show that our method can process large-scale datasets of 1,000-8,000 sequences. We believe that our novel pattern-based method enriches the current set of tools and methods for phylogenetic tree inference. The software is available under: http://algbio.cs.uni-duesseldorf.de/webapps/wa-download/.

  3. A Practical pedestrian approach to parsimonious regression with inaccurate inputs

    Directory of Open Access Journals (Sweden)

    Seppo Karrila

    2014-04-01

    Full Text Available A measurement result often dictates an interval containing the correct value. Interval data is also created by roundoff, truncation, and binning. We focus on such common interval uncertainty in data. Inaccuracy in model inputs is typically ignored on model fitting. We provide a practical approach for regression with inaccurate data: the mathematics is easy, and the linear programming formulations simple to use even in a spreadsheet. This self-contained elementary presentation introduces interval linear systems and requires only basic knowledge of algebra. Feature selection is automatic; but can be controlled to find only a few most relevant inputs; and joint feature selection is enabled for multiple modeled outputs. With more features than cases, a novel connection to compressed sensing emerges: robustness against interval errors-in-variables implies model parsimony, and the input inaccuracies determine the regularization term. A small numerical example highlights counterintuitive results and a dramatic difference to total least squares.

  4. The scenario on the origin of translation in the RNA world: in principle of replication parsimony

    Directory of Open Access Journals (Sweden)

    Ma Wentao

    2010-11-01

    Full Text Available Abstract Background It is now believed that in the origin of life, proteins should have been "invented" in an RNA world. However, due to the complexity of a possible RNA-based proto-translation system, this evolving process seems quite complicated and the associated scenario remains very blurry. Considering that RNA can bind amino acids with specificity, it has been reasonably supposed that initial peptides might have been synthesized on "RNA templates" containing multiple amino acid binding sites. This "Direct RNA Template (DRT" mechanism is attractive because it should be the simplest mechanism for RNA to synthesize peptides, thus very likely to have been adopted initially in the RNA world. Then, how this mechanism could develop into a proto-translation system mechanism is an interesting problem. Presentation of the hypothesis Here an explanation to this problem is shown considering the principle of "replication parsimony" --- genetic information tends to be utilized in a parsimonious way under selection pressure, due to its replication cost (e.g., in the RNA world, nucleotides and ribozymes for RNA replication. Because a DRT would be quite long even for a short peptide, its replication cost would be great. Thus the diversity and the length of functional peptides synthesized by the DRT mechanism would be seriously limited. Adaptors (proto-tRNAs would arise to allow a DRT's complementary strand (called "C-DRT" here to direct the synthesis of the same peptide synthesized by the DRT itself. Because the C-DRT is a necessary part in the DRT's replication, fewer turns of the DRT's replication would be needed to synthesize definite copies of the functional peptide, thus saving the replication cost. Acting through adaptors, C-DRTs could transform into much shorter templates (called "proto-mRNAs" here and substitute the role of DRTs, thus significantly saving the replication cost. A proto-rRNA corresponding to the small subunit rRNA would then emerge

  5. Approximate maximum parsimony and ancestral maximum likelihood.

    Science.gov (United States)

    Alon, Noga; Chor, Benny; Pardi, Fabio; Rapoport, Anat

    2010-01-01

    We explore the maximum parsimony (MP) and ancestral maximum likelihood (AML) criteria in phylogenetic tree reconstruction. Both problems are NP-hard, so we seek approximate solutions. We formulate the two problems as Steiner tree problems under appropriate distances. The gist of our approach is the succinct characterization of Steiner trees for a small number of leaves for the two distances. This enables the use of known Steiner tree approximation algorithms. The approach leads to a 16/9 approximation ratio for AML and asymptotically to a 1.55 approximation ratio for MP.

  6. Line pressure effects on differential pressure measurements

    International Nuclear Information System (INIS)

    Neff, G.G.; Evans, R.P.

    1982-01-01

    The performance of differential pressure transducers in experimental pressurized water reactor (PWR) systems was evaluated. Transient differential pressure measurements made using a simple calibration proportionality relating differential pressure to output voltage could have large measurement uncertainties. A more sophisticated calibration equation was derived to incorporate the effects of zero shifts and sensitivity shifts as pressure in the pressure sensing line changes with time. A comparison made between the original calibration proportionality equation and the derived compensation equation indicates that potential measurement uncertainties can be reduced

  7. A Parsimonious Bootstrap Method to Model Natural Inflow Energy Series

    Directory of Open Access Journals (Sweden)

    Fernando Luiz Cyrino Oliveira

    2014-01-01

    Full Text Available The Brazilian energy generation and transmission system is quite peculiar in its dimension and characteristics. As such, it can be considered unique in the world. It is a high dimension hydrothermal system with huge participation of hydro plants. Such strong dependency on hydrological regimes implies uncertainties related to the energetic planning, requiring adequate modeling of the hydrological time series. This is carried out via stochastic simulations of monthly inflow series using the family of Periodic Autoregressive models, PAR(p, one for each period (month of the year. In this paper it is shown the problems in fitting these models by the current system, particularly the identification of the autoregressive order “p” and the corresponding parameter estimation. It is followed by a proposal of a new approach to set both the model order and the parameters estimation of the PAR(p models, using a nonparametric computational technique, known as Bootstrap. This technique allows the estimation of reliable confidence intervals for the model parameters. The obtained results using the Parsimonious Bootstrap Method of Moments (PBMOM produced not only more parsimonious model orders but also adherent stochastic scenarios and, in the long range, lead to a better use of water resources in the energy operation planning.

  8. A tewlve detector coincidence spectrometer for on-line and off-line measurements of nuclear g-factors

    International Nuclear Information System (INIS)

    Alfter, I.; Bodenstedt, E.; Hamer, B.; Hoff, J. van den; Knichel, W.; Muenning, H.; Piel, S.; Schueth, J.; Sajok, R.

    1992-01-01

    A twelve detector γ-γ directional correlation setup is described which has been designed and constructed for high precision on-line and off-line IPAC measurements. A ring of twelve BaF 2 detectors which may be replaced by Ge detectors is arranged around a superconducting magnet providing a maximum magnetic field of 4.5 T. In on-line experiments the magnetic field has the direction of the beam which passes through a central bore of the magnet. The data acquisition system stores directly the Esub(γ 1 )-Esub(γ 2 ) coincidence matrices for all 66 two-detector combinations in two 8 Mbyte RAMs, one for each of the two field directions. This allows a very fast data evaluation with a small on-line computer. The apparatus got into operation one-and-a-halve years ago and revealed excellent properties. (orig.)

  9. Accurate micro Hall effect measurements on scribe line pads

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Petersen, Dirch Hjorth; Wang, Fei

    2009-01-01

    Hall mobility and sheet carrier density are important parameters to monitor in advanced semiconductor production. If micro Hall effect measurements are done on small pads in scribe lines, these parameters may be measured without using valuable test wafers. We report how Hall mobility can...... be extracted from micro four-point measurements performed on a rectangular pad. The dimension of the investigated pad is 400 × 430 ¿m2, and the probe pitches range from 20 ¿m to 50 ¿m. The Monte Carlo method is used to find the optimal way to perform the Hall measurement and extract Hall mobility most...

  10. On-line measurement and control in sustainable mineral processing and energy production

    International Nuclear Information System (INIS)

    Sowerby, B.D.

    2002-01-01

    Sustainable development can be defined as development that 'meets the needs of the present without compromising the ability of future generations to meet their own needs' (WCED, 1987). A sustainable minerals and energy industry will need to achieve a number of related objectives including greater energy efficiency, improved utilisation of ore deposits, improved utilisation of existing plant, improved product quality, reduction of waste material, reduction of pollution levels and improved safety margins. These objectives all relate in varying degrees to the triple bottom line of economic, social and environmental benefits. One critical component in achieving these objectives is to develop and apply improved control systems across the full range of industry applications from mining to processing and utilisation. However process control relies heavily on the availability of suitable on-line process instrumentation to provide the data and feedback necessary for its implementation. There is a lot of truth in the saying 'if you can't measure it you can't control it'. In the past measurement was achieved by manual sampling followed by sample preparation (such as drying, mixing, crushing and dividing) and off-line laboratory analysis. However this procedure is often subject to significant sampling errors and, most importantly, the measurements are too slow for control purposes. By contrast, on-line analysis can provide rapid and accurate measurement in real time thus opening up new possibilities for improved process control. As a result, there has been a rapid increase in the industrial application of on-line analysis instrumentation over the past few decades. The main purpose of this paper is to briefly review some past Australian developments of on-line analysis systems in the mineral and coal industries and to discuss present developments and future trends

  11. PTree: pattern-based, stochastic search for maximum parsimony phylogenies

    OpenAIRE

    Gregor, Ivan; Steinbr?ck, Lars; McHardy, Alice C.

    2013-01-01

    Phylogenetic reconstruction is vital to analyzing the evolutionary relationship of genes within and across populations of different species. Nowadays, with next generation sequencing technologies producing sets comprising thousands of sequences, robust identification of the tree topology, which is optimal according to standard criteria such as maximum parsimony, maximum likelihood or posterior probability, with phylogenetic inference methods is a computationally very demanding task. Here, we ...

  12. Measurements on the He-Ne laser lines near 633 nm

    Science.gov (United States)

    Steinhaus, David W.

    1983-09-01

    The red line from an inexpensive He-Ne laser is made up of several closely spaced lines. To separate these lines very high spectral resolution is required. This apparatus requirement can be met by a simple modification of a student Fabry-Perot interferometer. Laboratory measurements can then be made to verify the expected number, spacing, and polarization of these lines during a single afternoon laboratory session.

  13. On-line velocity measurements using phase probes at the SuperHILAC

    International Nuclear Information System (INIS)

    Feinberg, B.; Meaney, D.; Thatcher, R.; Timossi, C.

    1987-12-01

    Phase probes have been placed in several external beam lines at the LBL heavy ion linear accelerator (SuperHILAC) to provide non- destructive velocity measurements independent of the ion being accelerated. The system uses three probes in each line to obtain accurate velocity measurements at all beam energies. Automatic gain control and signal analysis are performed so that the energy/nucleon along with up to three probe signals are displayed on a vector graphics display with a refresh rate better than twice per second. The system uses a sensitive pseudo-correlation technique to pick out the signal from the noise, features simultaneous measurements of up to four ion velocities when more than one beam is being accelerated, and is controlled by a touch-screen operator interface. It is accurate to within /+-/0.25% and has provisions for on-line calibration tests. The phase probes thus provide a velocity measurement independent of the mass defect associated with the use of crystal detectors, which can become significant for heavy elements. They are now used as a routine tuning aid to ensure proper bunch structure, and as a beam velocity monitor. 3 refs., 5 figs

  14. On line local measurement of thermal neutron flux on BNCT patient using SPND

    International Nuclear Information System (INIS)

    Miller, M.E.; Sztejnberg Goncalves-Carralves, M.L.; Gonzalez, S.J.

    2006-01-01

    The first on-line neutron flux measurement on a patient using a self-powered neutron detector (SPND) was assessed during the fourth clinical trial of the Boron Neutron Capture Therapy (BNCT) Project carried out at the National Atomic Energy Commission of Argentina (CNEA) and the medical center Angel H. Roffo. The SPND was specially developed and assembled for BNCT by CNEA. Its small size, 1 cm sensible length and 1.9 mm diameter, allowed performing a localized measurement. Since the treated tumors were cutaneous melanomas of nodular type, the SPND was located on the patient's skin. The patient was exposed to three different and consecutive fields and in each of them the SPND was used to measure local thermal neutron fluxes at selected dosimetric reference points. The values of the measured fluxes agreed with the ones estimated by calculation. This trial also demonstrated the usefulness of the SPND for assessing flux on-line. (author)

  15. Assessing tolerance for wildlife: Clarifying relations between concepts and measures

    Science.gov (United States)

    Bruskotter, Jeremy T.; Singh, Ajay; Fulton, David C.; Slagle, Kristina

    2015-01-01

    Two parallel lines of inquiry, tolerance for and acceptance of wildlife populations, have arisen in the applied literature on wildlife conservation to assess probability of successfully establishing or increasing populations of controversial species. Neither of these lines is well grounded in social science theory, and diverse measures have been employed to assess tolerance, which inhibits comparability across studies. We empirically tested behavioral measures of tolerance against self-reports of previous policy-relevant behavior and behavioral intentions. Both composite behavioral measures were strongly correlated (r > .70) with two attitudinal measures of tolerance commonly employed in the literature. The strong correlation between attitudinal and behavioral measures suggests existing attitudinal measures represent valid, parsimonious measures of tolerance that may be useful when behavioral measures are too cumbersome or misreporting of behavior is anticipated. Our results demonstrate how behavioral measures of tolerance provide additional, useful information beyond general attitudinal measures.

  16. On the Accuracy of Ancestral Sequence Reconstruction for Ultrametric Trees with Parsimony.

    Science.gov (United States)

    Herbst, Lina; Fischer, Mareike

    2018-04-01

    We examine a mathematical question concerning the reconstruction accuracy of the Fitch algorithm for reconstructing the ancestral sequence of the most recent common ancestor given a phylogenetic tree and sequence data for all taxa under consideration. In particular, for the symmetric four-state substitution model which is also known as Jukes-Cantor model, we answer affirmatively a conjecture of Li, Steel and Zhang which states that for any ultrametric phylogenetic tree and a symmetric model, the Fitch parsimony method using all terminal taxa is more accurate, or at least as accurate, for ancestral state reconstruction than using any particular terminal taxon or any particular pair of taxa. This conjecture had so far only been answered for two-state data by Fischer and Thatte. Here, we focus on answering the biologically more relevant case with four states, which corresponds to ancestral sequence reconstruction from DNA or RNA data.

  17. Time-Lapse Monitoring of Subsurface Fluid Flow using Parsimonious Seismic Interferometry

    KAUST Repository

    Hanafy, Sherif; Li, Jing; Schuster, Gerard T.

    2017-01-01

    of parsimonious seismic interferometry with the time-lapse mentoring idea with field examples, where we were able to record 30 different data sets within a 2-hour period. The recorded data are then processed to generate 30 snapshots that shows the spread of water

  18. Size characterization of airborne SiO2 nanoparticles with on-line and off-line measurement techniques: an interlaboratory comparison study

    Science.gov (United States)

    Motzkus, C.; Macé, T.; Gaie-Levrel, F.; Ducourtieux, S.; Delvallee, A.; Dirscherl, K.; Hodoroaba, V.-D.; Popov, I.; Popov, O.; Kuselman, I.; Takahata, K.; Ehara, K.; Ausset, P.; Maillé, M.; Michielsen, N.; Bondiguel, S.; Gensdarmes, F.; Morawska, L.; Johnson, G. R.; Faghihi, E. M.; Kim, C. S.; Kim, Y. H.; Chu, M. C.; Guardado, J. A.; Salas, A.; Capannelli, G.; Costa, C.; Bostrom, T.; Jämting, Å. K.; Lawn, M. A.; Adlem, L.; Vaslin-Reimann, S.

    2013-10-01

    Results of an interlaboratory comparison on size characterization of SiO2 airborne nanoparticles using on-line and off-line measurement techniques are discussed. This study was performed in the framework of Technical Working Area (TWA) 34—"Properties of Nanoparticle Populations" of the Versailles Project on Advanced Materials and Standards (VAMAS) in the project no. 3 "Techniques for characterizing size distribution of airborne nanoparticles". Two types of nano-aerosols, consisting of (1) one population of nanoparticles with a mean diameter between 30.3 and 39.0 nm and (2) two populations of non-agglomerated nanoparticles with mean diameters between, respectively, 36.2-46.6 nm and 80.2-89.8 nm, were generated for characterization measurements. Scanning mobility particle size spectrometers (SMPS) were used for on-line measurements of size distributions of the produced nano-aerosols. Transmission electron microscopy, scanning electron microscopy, and atomic force microscopy were used as off-line measurement techniques for nanoparticles characterization. Samples were deposited on appropriate supports such as grids, filters, and mica plates by electrostatic precipitation and a filtration technique using SMPS controlled generation upstream. The results of the main size distribution parameters (mean and mode diameters), obtained from several laboratories, were compared based on metrological approaches including metrological traceability, calibration, and evaluation of the measurement uncertainty. Internationally harmonized measurement procedures for airborne SiO2 nanoparticles characterization are proposed.

  19. Size characterization of airborne SiO2 nanoparticles with on-line and off-line measurement techniques: an interlaboratory comparison study

    International Nuclear Information System (INIS)

    Motzkus, C.; Macé, T.; Gaie-Levrel, F.; Ducourtieux, S.; Delvallee, A.; Dirscherl, K.; Hodoroaba, V.-D.; Popov, I.; Popov, O.; Kuselman, I.; Takahata, K.; Ehara, K.; Ausset, P.; Maillé, M.; Michielsen, N.; Bondiguel, S.; Gensdarmes, F.; Morawska, L.; Johnson, G. R.; Faghihi, E. M.

    2013-01-01

    Results of an interlaboratory comparison on size characterization of SiO 2 airborne nanoparticles using on-line and off-line measurement techniques are discussed. This study was performed in the framework of Technical Working Area (TWA) 34—“Properties of Nanoparticle Populations” of the Versailles Project on Advanced Materials and Standards (VAMAS) in the project no. 3 “Techniques for characterizing size distribution of airborne nanoparticles”. Two types of nano-aerosols, consisting of (1) one population of nanoparticles with a mean diameter between 30.3 and 39.0 nm and (2) two populations of non-agglomerated nanoparticles with mean diameters between, respectively, 36.2–46.6 nm and 80.2–89.8 nm, were generated for characterization measurements. Scanning mobility particle size spectrometers (SMPS) were used for on-line measurements of size distributions of the produced nano-aerosols. Transmission electron microscopy, scanning electron microscopy, and atomic force microscopy were used as off-line measurement techniques for nanoparticles characterization. Samples were deposited on appropriate supports such as grids, filters, and mica plates by electrostatic precipitation and a filtration technique using SMPS controlled generation upstream. The results of the main size distribution parameters (mean and mode diameters), obtained from several laboratories, were compared based on metrological approaches including metrological traceability, calibration, and evaluation of the measurement uncertainty. Internationally harmonized measurement procedures for airborne SiO 2 nanoparticles characterization are proposed

  20. Patterns and effects of GC3 heterogeneity and parsimony informative sites on the phylogenetic tree of genes.

    Science.gov (United States)

    Ma, Shuai; Wu, Qi; Hu, Yibo; Wei, Fuwen

    2018-05-20

    The explosive growth in genomic data has provided novel insights into the conflicting signals hidden in phylogenetic trees. Although some studies have explored the effects of the GC content and parsimony informative sites (PIS) on the phylogenetic tree, the effect of the heterogeneity of the GC content at the first/second/third codon position on parsimony informative sites (GC1/2/3 PIS ) among different species and the effect of PIS on phylogenetic tree construction remain largely unexplored. Here, we used two different mammal genomic datasets to explore the patterns of GC1/2/3 PIS heterogeneity and the effect of PIS on the phylogenetic tree of genes: (i) all GC1/2/3 PIS have obvious heterogeneity between different mammals, and the levels of heterogeneity are GC3 PIS  > GC2 PIS  > GC1 PIS ; (ii) the number of PIS is positively correlated with the metrics of "good" gene tree topologies, and excluding the third codon position (C3) decreases the quality of gene trees by removing too many PIS. These results provide novel insights into the heterogeneity pattern of GC1/2/3 PIS in mammals and the relationship between GC3/PIS and gene trees. Additionally, it is necessary to carefully consider whether to exclude C3 to improve the quality of gene trees, especially in the super-tree method. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Sensing line effects on PWR-based differential pressure measurements

    International Nuclear Information System (INIS)

    Evans, R.P.; Neff, G.G.

    1982-01-01

    An incorrrect configuration of the fluid-filled pressure sensing lines connecting differential pressure transducers to the pressure taps in a pressurized water reactor system can cause errors in the measurement and, during rapid pressure transients, could cause the transducer to fail. Testing was performed in both static and dynamic modes to experimentally determine the effects of sensing lines of various lengths, diameters, and materials. Testing was performed at ambient temperature with absolute line pressures at about 17 MPa using water as the pressure transmission fluid

  2. On the Transmission Line Pulse Measurement Technique

    OpenAIRE

    X. Rodriguez; M. Eduardo; M. Harington

    2015-01-01

    Transmission Line Pulse is a short pulse (25ns to 150ns) measurement of the current-voltage (I/V) characteristics of the ESD protection built into an integrated circuit. The short TLP pulses are used to simulate the short ESD pulse threats and integrated circuit must tolerate without being damaged. In this work the fundamental principles of how the TLP pulse is generated and used to create I-V characteristic plots will be explored. The measurement will be then used to characterize the I-V cha...

  3. On-line fast flux measurements in the BR2 reactor

    International Nuclear Information System (INIS)

    Vermeeren, L.

    2009-01-01

    Since 2001, CEA-Cadarache and the Belgian Nuclear Research Centre SCK-CEN are collaborating on the development and in-pile qualification of subminiature fission chambers (diameter of 1.5 mm). Initially, efforts concentrated on fission chambers for the in-pile measurement of thermal fluxes (with 235 U as fissile material). Meanwhile successful long-term tests of the prototypes have been performed in various environments: in low temperature (40-100 degress Celsius) BR2 pool water (up to a thermal neutron fluence of 3 1 0 21 n/cm 2 ) and in the CALLISTO PWR loop (300 degrees Celsius, 155 bars). The long-term qualification of derived industrial detectors (Photonis CFUZ53) in CALLISTO is still ongoing. However, for various types of irradiations in research reactors, the knowledge of the evolution of the fast neutron flux is even of more interest than the thermal flux data. Therefore the collaboration program was extended to the development and the in-pile qualification of subminiature or miniature fission chambers (with 3 mm diameter) for fast neutron detection, for which 242 Pu was selected as the optimal fissile material. In order to achieve the on-line in-pile measurement of fast neutron flux, the fission chambers will be operated in the Campbelling mode (based on the mean square fluctuation of the detector current). In this mode the gamma induced contribution to the signal can be efficiently suppressed. Moreover, a data processing software will take into account the evolution of the fissile deposit in order to assess on-line the fast flux sensitivity and to correct for the low energy neutron contributions. The final objective is to qualify a Fast Neutron Detector System (FNDS) able to provide on-line data for local fast neutron fluxes in Material Testing Reactors. The on-line measurement of the fast neutron flux would contribute significantly to the characterization of the irradiation conditions during test experiments with materials and innovative fuel elements

  4. A parsimonious dynamic model for river water quality assessment.

    Science.gov (United States)

    Mannina, Giorgio; Viviani, Gaspare

    2010-01-01

    Water quality modelling is of crucial importance for the assessment of physical, chemical, and biological changes in water bodies. Mathematical approaches to water modelling have become more prevalent over recent years. Different model types ranging from detailed physical models to simplified conceptual models are available. Actually, a possible middle ground between detailed and simplified models may be parsimonious models that represent the simplest approach that fits the application. The appropriate modelling approach depends on the research goal as well as on data available for correct model application. When there is inadequate data, it is mandatory to focus on a simple river water quality model rather than detailed ones. The study presents a parsimonious river water quality model to evaluate the propagation of pollutants in natural rivers. The model is made up of two sub-models: a quantity one and a quality one. The model employs a river schematisation that considers different stretches according to the geometric characteristics and to the gradient of the river bed. Each stretch is represented with a conceptual model of a series of linear channels and reservoirs. The channels determine the delay in the pollution wave and the reservoirs cause its dispersion. To assess the river water quality, the model employs four state variables: DO, BOD, NH(4), and NO. The model was applied to the Savena River (Italy), which is the focus of a European-financed project in which quantity and quality data were gathered. A sensitivity analysis of the model output to the model input or parameters was done based on the Generalised Likelihood Uncertainty Estimation methodology. The results demonstrate the suitability of such a model as a tool for river water quality management.

  5. Ancestral Sequence Reconstruction with Maximum Parsimony.

    Science.gov (United States)

    Herbst, Lina; Fischer, Mareike

    2017-12-01

    One of the main aims in phylogenetics is the estimation of ancestral sequences based on present-day data like, for instance, DNA alignments. One way to estimate the data of the last common ancestor of a given set of species is to first reconstruct a phylogenetic tree with some tree inference method and then to use some method of ancestral state inference based on that tree. One of the best-known methods both for tree inference and for ancestral sequence inference is Maximum Parsimony (MP). In this manuscript, we focus on this method and on ancestral state inference for fully bifurcating trees. In particular, we investigate a conjecture published by Charleston and Steel in 1995 concerning the number of species which need to have a particular state, say a, at a particular site in order for MP to unambiguously return a as an estimate for the state of the last common ancestor. We prove the conjecture for all even numbers of character states, which is the most relevant case in biology. We also show that the conjecture does not hold in general for odd numbers of character states, but also present some positive results for this case.

  6. The dynamic effect of exchange-rate volatility on Turkish exports: Parsimonious error-correction model approach

    Directory of Open Access Journals (Sweden)

    Demirhan Erdal

    2015-01-01

    Full Text Available This paper aims to investigate the effect of exchange-rate stability on real export volume in Turkey, using monthly data for the period February 2001 to January 2010. The Johansen multivariate cointegration method and the parsimonious error-correction model are applied to determine long-run and short-run relationships between real export volume and its determinants. In this study, the conditional variance of the GARCH (1, 1 model is taken as a proxy for exchange-rate stability, and generalized impulse-response functions and variance-decomposition analyses are applied to analyze the dynamic effects of variables on real export volume. The empirical findings suggest that exchangerate stability has a significant positive effect on real export volume, both in the short and the long run.

  7. FPGA Hardware Acceleration of a Phylogenetic Tree Reconstruction with Maximum Parsimony Algorithm

    OpenAIRE

    BLOCK, Henry; MARUYAMA, Tsutomu

    2017-01-01

    In this paper, we present an FPGA hardware implementation for a phylogenetic tree reconstruction with a maximum parsimony algorithm. We base our approach on a particular stochastic local search algorithm that uses the Progressive Neighborhood and the Indirect Calculation of Tree Lengths method. This method is widely used for the acceleration of the phylogenetic tree reconstruction algorithm in software. In our implementation, we define a tree structure and accelerate the search by parallel an...

  8. Measurements of VUV lines on dense Z-pinch plasma

    International Nuclear Information System (INIS)

    Bertschinger, G.

    1980-01-01

    The transition n = 1 to n = 2 has the most simple structure of all hydrogen transitions and the corresponding spectralline Ly-α is therefore very appropriate to reveal discrepancies between theory and experiment. In this work mainly the Ly-α spectral line of neutral hydrogen has been studied. The electron density of the Z-pinch amounts to 1.5 x 10 24 m -3 with an electron temperature of about 1.2 x 10 5 K. In this parameter range the plasma can still be studied with spectroscopic methods in the visible spectral region. Based on a space and time resolved measurement of the continuous emission spectra the plasma parameters can be determined independent of line broadening. (orig./HT) [de

  9. Size characterization of airborne SiO{sub 2} nanoparticles with on-line and off-line measurement techniques: an interlaboratory comparison study

    Energy Technology Data Exchange (ETDEWEB)

    Motzkus, C., E-mail: charles.motzkus@lne.fr; Mace, T.; Gaie-Levrel, F.; Ducourtieux, S.; Delvallee, A. [Laboratoire National de Metrologie et d' Essais (LNE) (France); Dirscherl, K. [Danish Fundamental Metrology (DFM) (Denmark); Hodoroaba, V.-D. [BAM Federal Institute for Materials Research and Testing (Germany); Popov, I. [The Hebrew University of Jerusalem, Unit for Nanocharacterization (Israel); Popov, O.; Kuselman, I. [National Physical Laboratory of Israel (INPL) (Israel); Takahata, K.; Ehara, K. [National Institute of Advanced Industrial Science and Technology (AIST), National Metrology Institute of Japan (NMIJ) (Japan); Ausset, P.; Maille, M. [Universite Paris-Est Creteil et Universite Paris-Diderot, Laboratoire Interuniversitaire des Systemes Atmospheriques (LISA), UMR CNRS 7583 (France); Michielsen, N.; Bondiguel, S.; Gensdarmes, F. [Institut de Radioprotection et de Surete Nucleaire (IRSN), PSN-RES, SCA, LPMA (France); Morawska, L.; Johnson, G. R.; Faghihi, E. M. [Queensland University of Technology (QUT), International Laboratory for Air Quality and Health (ILAQH) (Australia); and others

    2013-10-15

    Results of an interlaboratory comparison on size characterization of SiO{sub 2} airborne nanoparticles using on-line and off-line measurement techniques are discussed. This study was performed in the framework of Technical Working Area (TWA) 34-'Properties of Nanoparticle Populations' of the Versailles Project on Advanced Materials and Standards (VAMAS) in the project no. 3 'Techniques for characterizing size distribution of airborne nanoparticles'. Two types of nano-aerosols, consisting of (1) one population of nanoparticles with a mean diameter between 30.3 and 39.0 nm and (2) two populations of non-agglomerated nanoparticles with mean diameters between, respectively, 36.2-46.6 nm and 80.2-89.8 nm, were generated for characterization measurements. Scanning mobility particle size spectrometers (SMPS) were used for on-line measurements of size distributions of the produced nano-aerosols. Transmission electron microscopy, scanning electron microscopy, and atomic force microscopy were used as off-line measurement techniques for nanoparticles characterization. Samples were deposited on appropriate supports such as grids, filters, and mica plates by electrostatic precipitation and a filtration technique using SMPS controlled generation upstream. The results of the main size distribution parameters (mean and mode diameters), obtained from several laboratories, were compared based on metrological approaches including metrological traceability, calibration, and evaluation of the measurement uncertainty. Internationally harmonized measurement procedures for airborne SiO{sub 2} nanoparticles characterization are proposed.

  10. Prediction of dissolved reactive phosphorus losses from small agricultural catchments: calibration and validation of a parsimonious model

    Directory of Open Access Journals (Sweden)

    C. Hahn

    2013-10-01

    Full Text Available Eutrophication of surface waters due to diffuse phosphorus (P losses continues to be a severe water quality problem worldwide, causing the loss of ecosystem functions of the respective water bodies. Phosphorus in runoff often originates from a small fraction of a catchment only. Targeting mitigation measures to these critical source areas (CSAs is expected to be most efficient and cost-effective, but requires suitable tools. Here we investigated the capability of the parsimonious Rainfall-Runoff-Phosphorus (RRP model to identify CSAs in grassland-dominated catchments based on readily available soil and topographic data. After simultaneous calibration on runoff data from four small hilly catchments on the Swiss Plateau, the model was validated on a different catchment in the same region without further calibration. The RRP model adequately simulated the discharge and dissolved reactive P (DRP export from the validation catchment. Sensitivity analysis showed that the model predictions were robust with respect to the classification of soils into "poorly drained" and "well drained", based on the available soil map. Comparing spatial hydrological model predictions with field data from the validation catchment provided further evidence that the assumptions underlying the model are valid and that the model adequately accounts for the dominant P export processes in the target region. Thus, the parsimonious RRP model is a valuable tool that can be used to determine CSAs. Despite the considerable predictive uncertainty regarding the spatial extent of CSAs, the RRP can provide guidance for the implementation of mitigation measures. The model helps to identify those parts of a catchment where high DRP losses are expected or can be excluded with high confidence. Legacy P was predicted to be the dominant source for DRP losses and thus, in combination with hydrologic active areas, a high risk for water quality.

  11. Consequence Valuing as Operation and Process: A Parsimonious Analysis of Motivation

    Science.gov (United States)

    Whelan, Robert; Barnes-Holmes, Dermot

    2010-01-01

    The concept of the motivating operation (MO) has been subject to 3 criticisms: (a) the terms and concepts employed do not always overlap with traditional behavior-analytic verbal practices; (b) the dual nature of the MO is unclear; and (c) there is a lack of adequate contact with empirical data. We offer a more parsimonious approach to motivation,…

  12. Assessing internet addiction using the parsimonious internet addiction components model—A preliminary study.

    OpenAIRE

    Kuss, D.J.; Shorter, G.W.; Rooij, A.J. van; Griffiths, M.D.; Schoenmakers, T.M.

    2014-01-01

    Internet usage has grown exponentially over the last decade. Research indicates that excessive Internet use can lead to symptoms associated with addiction. To date, assessment of potential Internet addiction has varied regarding populations studied and instruments used, making reliable prevalence estimations difficult. To overcome the present problems a preliminary study was conducted testing a parsimonious Internet addiction components model based on Griffiths’ addiction components (Journal ...

  13. Measurements of national radiation exposure rates on train lines in Tokai area

    International Nuclear Information System (INIS)

    Matsuda, Hideharu

    1996-01-01

    For data accumulation of natural radiation exposure rate derived from gamma-ray and cosmic-ray to evaluate population dose, the author measured the rate in the running vehicles of 12 JR Tokai lines, 17 Nagoya Railway lines, 4 Kinkinippon Railway lines and 1 line of Nagoya City Bus. A portable gamma spectrometer equipped with 3' in diameter x 3' NaI (Tl) scintillation detector was placed on the seat of the vehicle for measurement in the period of December, 1992-August, 1995. Gamma-ray and cosmic-ray exposure rates in air were assessed separately as reported before and expressed in Gy/h. The average exposure rate of gamma-ray in JR Tokai lines was 19.8 nGy/h and of cosmic-ray, 28.5 nGy/h, both of which were markedly varied from line to line. The average rates of gamma-and cosmic-ray were 21.6 nGy/h and 29.0 nGy/h, respectively, in Nagoya Railway lines and 20.9 nGy/h and 28.7 nGy/h, respectively, in Kinkinippon lines. In the city bus, the respective rates were 27.2 nGy/h and 27.0 nGy/h. Thus, the average rates of gamma-ray (about 20 nGy/h) and cosmic-ray (about 29 nGy/h) were not so different between JR and other private railway lines. In the bus, the former rate was slightly lower and the latter, slightly higher. However, the total rates of both rays were in the range of about 50-55 nGy/h in all vehicles examined. (H.O.)

  14. A simplified parsimonious higher order multivariate Markov chain model with new convergence condition

    Science.gov (United States)

    Wang, Chao; Yang, Chuan-sheng

    2017-09-01

    In this paper, we present a simplified parsimonious higher-order multivariate Markov chain model with new convergence condition. (TPHOMMCM-NCC). Moreover, estimation method of the parameters in TPHOMMCM-NCC is give. Numerical experiments illustrate the effectiveness of TPHOMMCM-NCC.

  15. On-line data processing apparatus for spectroscopic measurements of atomic uranium

    International Nuclear Information System (INIS)

    Miron, E.; Levin, L.A.; Erez, G; Baumatz, D; Goren, I.; Shpancer, I.

    1977-01-01

    A computer-based apparatus for on-line spectroscopic measurements of atomic uranium is described. The system is capable of enhancing the signal-to-noise ratio by averaging, and performing calculations. Computation flow charts and programs are included

  16. DNA fingerprinting of glioma cell lines and considerations on similarity measurements.

    Science.gov (United States)

    Bady, Pierre; Diserens, Annie-Claire; Castella, Vincent; Kalt, Stefanie; Heinimann, Karl; Hamou, Marie-France; Delorenzi, Mauro; Hegi, Monika E

    2012-06-01

    Glioma cell lines are an important tool for research in basic and translational neuro-oncology. Documentation of their genetic identity has become a requirement for scientific journals and grant applications to exclude cross-contamination and misidentification that lead to misinterpretation of results. Here, we report the standard 16 marker short tandem repeat (STR) DNA fingerprints for a panel of 39 widely used glioma cell lines as reference. Comparison of the fingerprints among themselves and with the large DSMZ database comprising 9 marker STRs for 2278 cell lines uncovered 3 misidentified cell lines and confirmed previously known cross-contaminations. Furthermore, 2 glioma cell lines exhibited identity scores of 0.8, which is proposed as the cutoff for detecting cross-contamination. Additional characteristics, comprising lack of a B-raf mutation in one line and a similarity score of 1 with the original tumor tissue in the other, excluded a cross-contamination. Subsequent simulation procedures suggested that, when using DNA fingerprints comprising only 9 STR markers, the commonly used similarity score of 0.8 is not sufficiently stringent to unambiguously differentiate the origin. DNA fingerprints are confounded by frequent genetic alterations in cancer cell lines, particularly loss of heterozygosity, that reduce the informativeness of STR markers and, thereby, the overall power for distinction. The similarity score depends on the number of markers measured; thus, more markers or additional cell line characteristics, such as information on specific mutations, may be necessary to clarify the origin.

  17. Solving of some Problems with On-Line Mode Measurement of Partial Discharges

    Directory of Open Access Journals (Sweden)

    Karel Zalis

    2004-01-01

    Full Text Available This paper deals with the problems discussing the transition from off-line diagnostic methods to on-line ones. Based on the experience with commercial partial discharge measuring equipment a new digital system for the evaluation of partial discharge measurement including software and hardware facilities has been developed at the Czech Technical University in Prague. Two expert systems work in this complex evaluating system: a rule-based expert system performing an amplitude analysis of partial discharge impulses for determining the damage of the insulation system, and a neural network which is used for a phase analysis of partial discharge impulses to determine the kind of partial discharge activity. Problem of the elimination of disturbances is also discussed.

  18. High-resolution Laboratory Measurements of Coronal Lines near the Fe IX Line at 171 Å

    Science.gov (United States)

    Beiersdorfer, Peter; Träbert, Elmar

    2018-02-01

    We present high-resolution laboratory measurements in the spectral region between 165 and 175 Å that focus on the emission from various ions of C, O, F, Ne, S, Ar, Fe, and Ni. This wavelength region is centered on the λ171 Fe IX channel of the Atmospheric Imaging Assembly on the Solar Dynamics Observatory, and we place special emphasis on the weaker emission lines of Fe IX predicted in this region. In general, our measurements show a multitude of weak lines missing in the current databases, where the emission lines of Ni are probably most in need of further identification and reclassification. We also find that the wavelengths of some of the known lines need updating. Using the multi-reference Møller–Plesset method for wavelength predictions and collisional-radiative modeling of the line intensities, we have made tentative assignments of more than a dozen lines to the spectrum of Fe IX, some of which have formerly been identified as Fe VII, Fe XIV, or Fe XVI lines. Several Fe features remain unassigned, although they appear to be either Fe VII or Fe X lines. Further work will be needed to complete and correct the spectral line lists in this wavelength region.

  19. Assessing Internet addiction using the parsimonious Internet addiction components model - a preliminary study [forthcoming

    OpenAIRE

    Kuss, DJ; Shorter, GW; Van Rooij, AJ; Griffiths, MD; Schoenmakers, T

    2014-01-01

    Internet usage has grown exponentially over the last decade. Research indicates that excessive Internet use can lead to symptoms associated with addiction. To date, assessment of potential Internet addiction has varied regarding populations studied and instruments used, making reliable prevalence estimations difficult. To overcome the present problems a preliminary study was conducted testing a parsimonious Internet addiction components model based on Griffiths’ addiction components (2005), i...

  20. Establishment of X-ray Measurement System for On-line Monitoring of Water Content in Powder

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, J. S. [Korea Institute of Industrial Technology, Cheonan (Korea, Republic of); Choi, Y. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Choi, B. J. [Idealsystem Co., Daegu (Korea, Republic of)

    2012-05-15

    On-line process monitoring is of critical importance in many industries, and therefore a variety of the state-of-the-art physical and chemical measurement techniques have been proposed. But, these techniques have their own pros and cons under the field process environments. Because the field process environments are very different from the well-organized chemical laboratories, many factors should be considered in order to optimize the process monitoring system. However, there have been few studies on the on-line measurement of water content in powder materials. For that reason, the X-ray measurement system based on the X-ray scattering technique, which was first proposed in 2011 as a new method for the determination of water content in powder, has been improved. in the present study, our original X-ray measurement system has been modified for more rapid, simple, and adequate for maximizing the field applicability of the on-line monitoring system

  1. A large version of the small parsimony problem

    DEFF Research Database (Denmark)

    Fredslund, Jakob; Hein, Jotun; Scharling, Tejs

    2003-01-01

    the most parsimonious assignment of nucleotides. The gaps of the alignment are represented in a so-called gap graph, and through theoretically sound preprocessing the graph is reduced to pave the way for a running time which in all but the most pathological examples is far better than the exponential worst......Given a multiple alignment over $k$ sequences, an evolutionary tree relating the sequences, and a subadditive gap penalty function (e.g. an affine function), we reconstruct the internal nodes of the tree optimally: we find the optimal explanation in terms of indels of the observed gaps and find...... case time. E.g. for a tree with nine leaves and a random alignment of length 10.000 with 60% gaps, the running time is on average around 45 seconds. For a real alignment of length 9868 of nine HIV-1 sequences, the running time is less than one second....

  2. Vector Autoregressions with Parsimoniously Time Varying Parameters and an Application to Monetary Policy

    DEFF Research Database (Denmark)

    Callot, Laurent; Kristensen, Johannes Tang

    the monetary policy response to inflation and business cycle fluctuations in the US by estimating a parsimoniously time varying parameter Taylor rule.We document substantial changes in the policy response of the Fed in the 1970s and 1980s, and since 2007, but also document the stability of this response...

  3. Distributed power-line outage detection based on wide area measurement system.

    Science.gov (United States)

    Zhao, Liang; Song, Wen-Zhan

    2014-07-21

    In modern power grids, the fast and reliable detection of power-line outages is an important functionality, which prevents cascading failures and facilitates an accurate state estimation to monitor the real-time conditions of the grids. However, most of the existing approaches for outage detection suffer from two drawbacks, namely: (i) high computational complexity; and (ii) relying on a centralized means of implementation. The high computational complexity limits the practical usage of outage detection only for the case of single-line or double-line outages. Meanwhile, the centralized means of implementation raises security and privacy issues. Considering these drawbacks, the present paper proposes a distributed framework, which carries out in-network information processing and only shares estimates on boundaries with the neighboring control areas. This novel framework relies on a convex-relaxed formulation of the line outage detection problem and leverages the alternating direction method of multipliers (ADMM) for its distributed solution. The proposed framework invokes a low computational complexity, requiring only linear and simple matrix-vector operations. We also extend this framework to incorporate the sparse property of the measurement matrix and employ the LSQRalgorithm to enable a warm start, which further accelerates the algorithm. Analysis and simulation tests validate the correctness and effectiveness of the proposed approaches.

  4. On-Line Flatness Measurement in the Steelmaking Industry

    Directory of Open Access Journals (Sweden)

    Rubén Usamentiaga

    2013-08-01

    Full Text Available Shape is a key characteristic to determine the quality of outgoing flat-rolled products in the steel industry. It is greatly influenced by flatness, a feature to describe how the surface of a rolled product approaches a plane. Flatness is of the utmost importance in steelmaking, since it is used by most downstream processes and customers for the acceptance or rejection of rolled products. Flatness sensors compute flatness measurements based on comparing the length of several longitudinal fibers of the surface of the product under inspection. Two main different approaches are commonly used. On the one hand, most mechanical sensors measure the tensile stress across the width of the rolled product, while manufacturing and estimating the fiber lengths from this stress. On the other hand, optical sensors measure the length of the fibers by means of light patterns projected onto the product surface. In this paper, we review the techniques and the main sensors used in the steelmaking industry to measure and quantify flatness defects in steel plates, sheets and strips. Most of these techniques and sensors can be used in other industries involving rolling mills or continuous production lines, such as aluminum, copper and paper, to name a few. Encompassed in the special issue, State-of-the-Art Sensors Technology in Spain 2013, this paper also reviews the most important flatness sensors designed and developed for the steelmaking industry in Spain.

  5. On-Line Flatness Measurement in the Steelmaking Industry

    Science.gov (United States)

    Molleda, Julio; Usamentiaga, Rubén; Garcίa, Daniel F.

    2013-01-01

    Shape is a key characteristic to determine the quality of outgoing flat-rolled products in the steel industry. It is greatly influenced by flatness, a feature to describe how the surface of a rolled product approaches a plane. Flatness is of the utmost importance in steelmaking, since it is used by most downstream processes and customers for the acceptance or rejection of rolled products. Flatness sensors compute flatness measurements based on comparing the length of several longitudinal fibers of the surface of the product under inspection. Two main different approaches are commonly used. On the one hand, most mechanical sensors measure the tensile stress across the width of the rolled product, while manufacturing and estimating the fiber lengths from this stress. On the other hand, optical sensors measure the length of the fibers by means of light patterns projected onto the product surface. In this paper, we review the techniques and the main sensors used in the steelmaking industry to measure and quantify flatness defects in steel plates, sheets and strips. Most of these techniques and sensors can be used in other industries involving rolling mills or continuous production lines, such as aluminum, copper and paper, to name a few. Encompassed in the special issue, State-of-the-Art Sensors Technology in Spain 2013, this paper also reviews the most important flatness sensors designed and developed for the steelmaking industry in Spain. PMID:23939583

  6. A Comparison of Multiscale Permutation Entropy Measures in On-Line Depth of Anesthesia Monitoring.

    Science.gov (United States)

    Su, Cui; Liang, Zhenhu; Li, Xiaoli; Li, Duan; Li, Yongwang; Ursino, Mauro

    2016-01-01

    Multiscale permutation entropy (MSPE) is becoming an interesting tool to explore neurophysiological mechanisms in recent years. In this study, six MSPE measures were proposed for on-line depth of anesthesia (DoA) monitoring to quantify the anesthetic effect on the real-time EEG recordings. The performance of these measures in describing the transient characters of simulated neural populations and clinical anesthesia EEG were evaluated and compared. Six MSPE algorithms-derived from Shannon permutation entropy (SPE), Renyi permutation entropy (RPE) and Tsallis permutation entropy (TPE) combined with the decomposition procedures of coarse-graining (CG) method and moving average (MA) analysis-were studied. A thalamo-cortical neural mass model (TCNMM) was used to generate noise-free EEG under anesthesia to quantitatively assess the robustness of each MSPE measure against noise. Then, the clinical anesthesia EEG recordings from 20 patients were analyzed with these measures. To validate their effectiveness, the ability of six measures were compared in terms of tracking the dynamical changes in EEG data and the performance in state discrimination. The Pearson correlation coefficient (R) was used to assess the relationship among MSPE measures. CG-based MSPEs failed in on-line DoA monitoring at multiscale analysis. In on-line EEG analysis, the MA-based MSPE measures at 5 decomposed scales could track the transient changes of EEG recordings and statistically distinguish the awake state, unconsciousness and recovery of consciousness (RoC) state significantly. Compared to single-scale SPE and RPE, MSPEs had better anti-noise ability and MA-RPE at scale 5 performed best in this aspect. MA-TPE outperformed other measures with faster tracking speed of the loss of unconsciousness. MA-based multiscale permutation entropies have the potential for on-line anesthesia EEG analysis with its simple computation and sensitivity to drug effect changes. CG-based multiscale permutation

  7. Mobile on-line working radioaerosol-measuring systems in Baden-Wuerttemberg

    International Nuclear Information System (INIS)

    Aures, R.; Wenzel, H.

    1998-01-01

    In Baden-Wuerttemberg eight on-line measuring radioaerosol monitoring stations are successfully working since a lot of years. These monitoring stations spread over the whole country give only a rough overview of the radiological situation in the environment after an event like the Chernobyl accident. But it is expensive to increase the number of the monitoring stations in this network. This is why the 'Landesanstalt fuer Umweltschutz Baden-Wuerttemberg' (LfU) got the order from the 'Ministerium fuer Umwelt und Verkehr Baden-Wuerttemberg' to conceive a mobile on-line working radioaerosol-measuring system for environmental measurements (MORAM). The LfU had made the plans and a company built up the first prototype. In action the MORAM should send every time automatically data of radioactivity in the air and datas of meteorology from its position to the controlling center in Karlsruhe. The MORAM works by remote control, needs little servicing and is independent from main connection. In case of a nuclear event several MORAMs could be used as a local monitoring network or they could increase the number of the radioaerosol monitoring stations for a certain time. Normally, the MORAMs will be storaged and are always ready for action. All the tests with the prototype 1 are finished in the meantime and the result of the tests is a new improved prototype 2, which can be used in the emergency case. This prototype was given to the LfU. (orig.) [de

  8. Optical fiber-spectrophotometer coupling: when will the measurement be on line

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    Ten years of research and development made at CEA in colorimetry and remote spectrometry by optical fibers allow to define more precisely the best conditions for on-line measurement in industrial process controls and in laboratory analysis in adverse environment. This article presents the new possibilities brought by this type of measurement. One of them is the simultaneous determination of many components; current studies concern the control ''in situ'' of uranium (IV) and (VI) and plutonium (III) and (IV) mixtures [fr

  9. On-line and precise measurement of iron wear using thin layer activation reactions by proton beam

    International Nuclear Information System (INIS)

    Kosako, Toshiso; Nishimura, Kazuo.

    1990-01-01

    For the purpose of the on-line measurement of iron wear, thin layer activation (TLA) method or surface layer activation (SLA) method has been carried out since early 1970s. This method uses the irradiation of charged particle beam like protons from an accelerator onto a metal surface to produce a thin activated layer of several tens μm. The wear of this activated layer is measured by nondestructive on-line method with a radiation detector. There are two methods of the measurement. One is the activity loss measurement on the surface, and the other is the activity measurement of the metal debris collected in a filter. The former method is considered here. The purpose it to measure the wear of engine cam noses to help the development of good engine oil. Proton beam irradiation with a tandem van de Graaff accelerator, wear calibration using a gamma ray spectrometer, on-line wear measurement of cam noses of car engines by TLA method and so on are reported. The 7.00 MeV proton beam from a van de Graaff accelerator was used for activation, and Co-56, Co-57 and Co-58 were obtained in thin layers. (K.I.)

  10. On-line measurement of microwave power in ECR ion source

    International Nuclear Information System (INIS)

    Zhou Changgeng; Kang Wu; Hu Yonghong; Li Yan; Lou Benchao; Zu Xiulan; Xiong Riheng; Chen Junguang; Li Xiaoyun

    2005-01-01

    It is a new technology to apply an ECR ion source to the neutron generator. Because of the structure limitation, working state of the ECR ion source could not be judged by the color of gas discharging in discharge chamber. Therefore, it was hard to estimate if the ECR ion source was working properly in the neutron generator. The method to resolve the problem was described in this paper. The microwave power was measured on-line by a directional coupler and a small microwave power meter. The ion beam current could be educed from the measured incidence microwave power, and discharge state in discharge chamber could be determined. (authors)

  11. Universal control and measuring system for modern classic and amorphous magnetic materials single/on-line strip testers

    Science.gov (United States)

    Zemánek, Ivan; Havlíček, Václav

    2006-09-01

    A new universal control and measuring system for classic and amorphous soft magnetic materials single/on-line strip testing has been developed at the Czech Technical University in Prague. The measuring system allows to measure magnetization characteristic and specific power losses of different tested materials (strips) at AC magnetization of arbitrary magnetic flux density waveform at wide range of frequencies 20 Hz-20 kHz. The measuring system can be used for both single strip testing in laboratories and on-line strip testing during the production process. The measuring system is controlled by two-stage master-slave control system consisting of the external PC (master) completed by three special A/D measuring plug-in boards, and local executing control unit (slave) with one-chip microprocessor 8051, connected with PC by the RS232 serial line. The "user friendly" powerful control software implemented on the PC and the effective program code for the microprocessor give possibility for full automatic measurement with high measuring power and high measuring accuracy.

  12. On-line depth measurement for laser-drilled holes based on the intensity of plasma emission

    Science.gov (United States)

    Ho, Chao-Ching; Chiu, Chih-Mu; Chang, Yuan-Jen; Hsu, Jin-Chen; Kuo, Chia-Lung

    2014-09-01

    The direct time-resolved depth measurement of blind holes is extremely difficult due to the short time interval and the limited space inside the hole. This work presents a method that involves on-line plasma emission acquisition and analysis to obtain correlations between the machining processes and the optical signal output. Given that the depths of laser-machined holes can be estimated on-line using a coaxial photodiode, this was employed in our inspection system. Our experiments were conducted in air under normal atmospheric conditions without gas assist. The intensity of radiation emitted from the vaporized material was found to correlate with the depth of the hole. The results indicate that the estimated depths of the laser-drilled holes were inversely proportional to the maximum plasma light emission measured for a given laser pulse number.

  13. Smile line assessment comparing quantitative measurement and visual estimation.

    Science.gov (United States)

    Van der Geld, Pieter; Oosterveld, Paul; Schols, Jan; Kuijpers-Jagtman, Anne Marie

    2011-02-01

    Esthetic analysis of dynamic functions such as spontaneous smiling is feasible by using digital videography and computer measurement for lip line height and tooth display. Because quantitative measurements are time-consuming, digital videography and semiquantitative (visual) estimation according to a standard categorization are more practical for regular diagnostics. Our objective in this study was to compare 2 semiquantitative methods with quantitative measurements for reliability and agreement. The faces of 122 male participants were individually registered by using digital videography. Spontaneous and posed smiles were captured. On the records, maxillary lip line heights and tooth display were digitally measured on each tooth and also visually estimated according to 3-grade and 4-grade scales. Two raters were involved. An error analysis was performed. Reliability was established with kappa statistics. Interexaminer and intraexaminer reliability values were high, with median kappa values from 0.79 to 0.88. Agreement of the 3-grade scale estimation with quantitative measurement showed higher median kappa values (0.76) than the 4-grade scale estimation (0.66). Differentiating high and gummy smile lines (4-grade scale) resulted in greater inaccuracies. The estimation of a high, average, or low smile line for each tooth showed high reliability close to quantitative measurements. Smile line analysis can be performed reliably with a 3-grade scale (visual) semiquantitative estimation. For a more comprehensive diagnosis, additional measuring is proposed, especially in patients with disproportional gingival display. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  14. Emittance Measurements For Future LHC Beams Using The PS Booster Measurement Line

    CERN Document Server

    Abelleira, Jose; Mikulec, Bettina; Di Giovanni, Gian Piero; CERN. Geneva. ATS Department

    2017-01-01

    The CERN PS Booster measurement line contains three pairs of SEM grids separated by drift space that measures the beam size in both planes. The combined analysis of these grids allows calculating a value for the transverse beam emittances. The precision of such a measurement depends on the ratio of RMS beam size and wire spacing. Within the LIU-PSB upgrade the extraction kinetic energy of the PSB will be increased from the current 1.4 GeV to 2.0 GeV. This will result in smaller transverse beam sizes for some of the future beams. The present layout of the transverse emittance measurement line is reviewed to verify if it will satisfy future requirements.

  15. On-line measurement with automatic emulsion analysis system and off-line data processing (E531 neutrino experiment)

    International Nuclear Information System (INIS)

    Miyanishi, Motoaki

    1984-01-01

    The automatic emulsion analysis system developed by Nagoya cosmic ray observation group was practically used for the experiment (FNAL-E531) on determining the lifetime of charm particles for the first time in the world, and achieved a great successful result. The system consists of four large precise coordinate-measuring stages capable of conducting simultaneous measurement and multiple (currently four) DOMS (digitized on-line microscope), supported with one mini-computer (ECLIPS S/130). The purpose of E531 experiment was the determination of charm particle lifetime. The experiment was carried out at FNAL, USA, and by the irradiation of wide band ν sub(μ) beam equivalent to 7 x 10 18 of 350 GeV/c protons. The detector was a hybrid system of emulsions and a counter spectrometer. The scan of neutrino reaction, the scan of charm particles, and charm event measurement were analyzed in emulsions, and the on-line programs for-respective analyses were created. Nagoya group has found 726 neutrino reactions in the first run, obtained 37 charm particle candidates, and found 1442 neutrino reactions in the second run, and obtained 56 charm particle candidates. The capability of the automatic emulsion analysis system in terms of the time equired for analysis is in total 3.5 hours per event; 15 minutes for C.S. scan, 15 minutes for coupling to module, 20 minutes for tracing to vertex, 1 hour for neutrino reaction measurement, 10 minutes for offline data processing and 1.5 hours for charm particle scanning. (Wakatsuki, Y.)

  16. E-line: A new crystal collimator beam line for source size measurements at CHESS

    International Nuclear Information System (INIS)

    White, Jeffrey A.; Revesz, Peter; Finkelstein, Ken

    2007-01-01

    A new X-ray beam line has been constructed at cornell high energy synchrotron source (CHESS) to measure the vertical and horizontal source size of the positron particle beam. The cornell laboratory of elementary particle physics (LEPP) operates the storage ring (CESR) for X-ray generation for the CHESS user community by circulating electrons and their antimatter counterpart positrons in counter-rotating beams. As the laboratory reduces the emittances of particle beams to increase X-ray brilliance, there has been an increasing need for diagnostic tools to measure and monitor source size. A beam line front end that accesses the positron synchrotron light has been fitted with an experimental chamber and apparatus of compact design capable of horizontal and vertical source size measurement using the 'crystal collimator' technique, and an additional setup for vertical beam position monitoring using a luminescence-based X-ray video beam position monitoring system. The crystal collimators each consist of two Si(2 2 0) crystals in a dispersive (+,+) arrangement that diffract X-rays to a fluorescent material coated on a view port observed with a CCD camera. Measurements of the positron vertical beam size using the crystal collimation method at E-line are compared with measurements of visible synchrotron light at a remotely located dedicated port on the storage ring

  17. Diffractive optical element-based glossmeter for the on-line measurement of normal reflectance on a printed porous coated paper

    Science.gov (United States)

    Oksman, Antti; Kuivalainen, Kalle; Ta˚G, Carl-Mikael; Juuti, Mikko; Mattila, Rauno; Hietala, Eero; Gane, Patrick A. C.; Peiponen, Kai-Erik

    2011-04-01

    Gloss of a product, such as print gloss, is mainly inspected with conventional white light glossmeters both at laboratory or production facilities. However, problems occur in conventional gloss measurement when the inspected surface is vertically moved in the plane of incidence and reflection or when the measurement area is small or curved. For a partial solution to these problems, we have previously introduced diffractive optical element-based glossmeters (DOGs) for the gloss inspection in laboratories and off-line use. We present a new construction of DOG, termed μDOG 1D, for the one-dimensional on-line print gloss measurement, in the form of the reflectance determination normal to the surface. The function of the glossmeter is demonstrated by laboratory tests and on-line measurements at a heat-set web offset printing machine. It is shown that gloss (i.e., normal reflectance) and minute gloss variation of papers and prints can be measured at the printing line using the glossmeter. This glossmeter is expected to be useful in real-time monitoring of the gloss and surface-specific absorption not only in the printing industry but also in inspection of products in other industrial sectors, such as metal finishing, laminating, paper, and construction materials manufacturing.

  18. Polarization measurement of iron L-shell lines on EBIT-I

    International Nuclear Information System (INIS)

    Chen, Hui; Beiersdorfer, Peter; Robbins, Darron; Smith, A.J.; Gu, Ming Feng

    2004-01-01

    We report measurements of the line polarization of Ne-like and F-like of iron n=3 to n=2 transitions in the x-ray region. We used the ''two-crystal technique'' developed in previous polarization measurements in our laboratory. Preliminary results from our measurements are presented together with the theoretical calculations using the Flexible Atomic Code (FAC). Our calculations show that contributions from cascades play an important role in the polarization calculations of most of the transitions. The uncertainties and difficulties of our experiments are also discussed. (author)

  19. On the Use of Line Depth Ratios to Measure Starspot Properties on Magnetically Active Stars

    Science.gov (United States)

    O'Neal, Douglas

    2006-07-01

    Photometric and spectroscopic techniques have proven to be effective ways to measure the properties of dark, cool starspots on magnetically active stars. Recently, a technique was introduced using atomic line depth ratios (LDRs) to measure starspot properties. Carefully reproducing this technique using a new set of spectroscopic observations of active stars, we find that the LDR technique encounters difficulties, specifically by overestimating spot temperatures (because the atomic lines blend with titanium oxide absorption in cooler spots) and by not tightly constraining the filling factor of spots. While the use of LDRs for active star studies has great promise, we believe that these concerns need to be addressed before the technique is more widely applied. This paper includes data taken at McDonald Observatory of the University of Texas at Austin.

  20. E-line: A new crystal collimator beam line for source size measurements at CHESS

    Energy Technology Data Exchange (ETDEWEB)

    White, Jeffrey A. [CHESS, Cornell High Energy Synchrotron Source, Cornell University, Ithaca, NY 14850-8001 (United States)], E-mail: jaw7@cornell.edu; Revesz, Peter; Finkelstein, Ken [CHESS, Cornell High Energy Synchrotron Source, Cornell University, Ithaca, NY 14850-8001 (United States)

    2007-11-11

    A new X-ray beam line has been constructed at cornell high energy synchrotron source (CHESS) to measure the vertical and horizontal source size of the positron particle beam. The cornell laboratory of elementary particle physics (LEPP) operates the storage ring (CESR) for X-ray generation for the CHESS user community by circulating electrons and their antimatter counterpart positrons in counter-rotating beams. As the laboratory reduces the emittances of particle beams to increase X-ray brilliance, there has been an increasing need for diagnostic tools to measure and monitor source size. A beam line front end that accesses the positron synchrotron light has been fitted with an experimental chamber and apparatus of compact design capable of horizontal and vertical source size measurement using the 'crystal collimator' technique, and an additional setup for vertical beam position monitoring using a luminescence-based X-ray video beam position monitoring system. The crystal collimators each consist of two Si(2 2 0) crystals in a dispersive (+,+) arrangement that diffract X-rays to a fluorescent material coated on a view port observed with a CCD camera. Measurements of the positron vertical beam size using the crystal collimation method at E-line are compared with measurements of visible synchrotron light at a remotely located dedicated port on the storage ring.

  1. A new mathematical modeling for pure parsimony haplotyping problem.

    Science.gov (United States)

    Feizabadi, R; Bagherian, M; Vaziri, H R; Salahi, M

    2016-11-01

    Pure parsimony haplotyping (PPH) problem is important in bioinformatics because rational haplotyping inference plays important roles in analysis of genetic data, mapping complex genetic diseases such as Alzheimer's disease, heart disorders and etc. Haplotypes and genotypes are m-length sequences. Although several integer programing models have already been presented for PPH problem, its NP-hardness characteristic resulted in ineffectiveness of those models facing the real instances especially instances with many heterozygous sites. In this paper, we assign a corresponding number to each haplotype and genotype and based on those numbers, we set a mixed integer programing model. Using numbers, instead of sequences, would lead to less complexity of the new model in comparison with previous models in a way that there are neither constraints nor variables corresponding to heterozygous nucleotide sites in it. Experimental results approve the efficiency of the new model in producing better solution in comparison to two state-of-the art haplotyping approaches. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Parsimonious Ways to Use Vision for Navigation

    Directory of Open Access Journals (Sweden)

    Paul Graham

    2012-05-01

    Full Text Available The use of visual information for navigation appears to be a universal strategy for sighted animals, amongst which, one particular group of expert navigators are the ants. The broad interest in studies of ant navigation is in part due to their small brains, thus biomimetic engineers expect to be impressed by elegant control solutions, and psychologists might hope for a description of the minimal cognitive requirements for complex spatial behaviours. In this spirit, we have been taking an interdisciplinary approach to the visual guided navigation of ants in their natural habitat. Behavioural experiments and natural image statistics show that visual navigation need not depend on the remembering or recognition of objects. Further modelling work suggests how simple behavioural routines might enable navigation using familiarity detection rather than explicit recall, and we present a proof of concept that visual navigation using familiarity can be achieved without specifying when or what to learn, nor separating routes into sequences of waypoints. We suggest that our current model represents the only detailed and complete model of insect route guidance to date. What's more, we believe the suggested mechanisms represent useful parsimonious hypotheses for the visually guided navigation in larger-brain animals.

  3. Parsimonious data: How a single Facebook like predicts voting behavior in multiparty systems.

    Directory of Open Access Journals (Sweden)

    Jakob Bæk Kristensen

    Full Text Available This study shows how liking politicians' public Facebook posts can be used as an accurate measure for predicting present-day voter intention in a multiparty system. We highlight that a few, but selective digital traces produce prediction accuracies that are on par or even greater than most current approaches based upon bigger and broader datasets. Combining the online and offline, we connect a subsample of surveyed respondents to their public Facebook activity and apply machine learning classifiers to explore the link between their political liking behaviour and actual voting intention. Through this work, we show that even a single selective Facebook like can reveal as much about political voter intention as hundreds of heterogeneous likes. Further, by including the entire political like history of the respondents, our model reaches prediction accuracies above previous multiparty studies (60-70%. The main contribution of this paper is to show how public like-activity on Facebook allows political profiling of individual users in a multiparty system with accuracies above previous studies. Beside increased accuracies, the paper shows how such parsimonious measures allows us to generalize our findings to the entire population of a country and even across national borders, to other political multiparty systems. The approach in this study relies on data that are publicly available, and the simple setup we propose can with some limitations, be generalized to millions of users in other multiparty systems.

  4. Catchment legacies and time lags: a parsimonious watershed model to predict the effects of legacy storage on nitrogen export.

    Directory of Open Access Journals (Sweden)

    Kimberly J Van Meter

    Full Text Available Nutrient legacies in anthropogenic landscapes, accumulated over decades of fertilizer application, lead to time lags between implementation of conservation measures and improvements in water quality. Quantification of such time lags has remained difficult, however, due to an incomplete understanding of controls on nutrient depletion trajectories after changes in land-use or management practices. In this study, we have developed a parsimonious watershed model for quantifying catchment-scale time lags based on both soil nutrient accumulations (biogeochemical legacy and groundwater travel time distributions (hydrologic legacy. The model accurately predicted the time lags observed in an Iowa watershed that had undergone a 41% conversion of area from row crop to native prairie. We explored the time scales of change for stream nutrient concentrations as a function of both natural and anthropogenic controls, from topography to spatial patterns of land-use change. Our results demonstrate that the existence of biogeochemical nutrient legacies increases time lags beyond those due to hydrologic legacy alone. In addition, we show that the maximum concentration reduction benefits vary according to the spatial pattern of intervention, with preferential conversion of land parcels having the shortest catchment-scale travel times providing proportionally greater concentration reductions as well as faster response times. In contrast, a random pattern of conversion results in a 1:1 relationship between percent land conversion and percent concentration reduction, irrespective of denitrification rates within the landscape. Our modeling framework allows for the quantification of tradeoffs between costs associated with implementation of conservation measures and the time needed to see the desired concentration reductions, making it of great value to decision makers regarding optimal implementation of watershed conservation measures.

  5. Inverse kinetics equations for on line measurement of reactivity using personal computer

    International Nuclear Information System (INIS)

    Ratemi, Wajdi; El Gadamsi, Walied; Beleid, Abdul Kariem

    1993-01-01

    Computer with their astonishing speed of calculations along with their easy connection to real systems, are very appropriate for digital measurements of real system variables. In the nuclear industry, such computer application will produce compact control rooms of real power plants, where information and results display can be obtained through push button concept. In our study, we use two personal computers for the purpose of simulation and measurement. One of them is used as a digital simulator to a real reactor, where we effectively simulate the reactor power through a cross talk network. The computed power is passed at certain chosen sampling time to the other computer. The purpose of the other computer is to use the inverse kinetics equations to calculate the reactivity parameter based on the received power and then it performs on line display of the power curve and the reactivity curve using color graphics. In this study, we use the one group version of the inverse kinetics algorithm which can easily be extended to larger group version. The language of programming used in Turbo BASIC, which is very comparable, in terms of efficiency, to FORTRAN language, besides its effective graphics routines. With the use of the extended version of the Inverse Kinetics algorithm, we can effectively apply this techniques of measurement for the purpose of on line display of the reactivity of the Tajoura Research Reactor. (author)

  6. Linearized spectrum correlation analysis for line emission measurements.

    Science.gov (United States)

    Nishizawa, T; Nornberg, M D; Den Hartog, D J; Sarff, J S

    2017-08-01

    A new spectral analysis method, Linearized Spectrum Correlation Analysis (LSCA), for charge exchange and passive ion Doppler spectroscopy is introduced to provide a means of measuring fast spectral line shape changes associated with ion-scale micro-instabilities. This analysis method is designed to resolve the fluctuations in the emission line shape from a stationary ion-scale wave. The method linearizes the fluctuations around a time-averaged line shape (e.g., Gaussian) and subdivides the spectral output channels into two sets to reduce contributions from uncorrelated fluctuations without averaging over the fast time dynamics. In principle, small fluctuations in the parameters used for a line shape model can be measured by evaluating the cross spectrum between different channel groupings to isolate a particular fluctuating quantity. High-frequency ion velocity measurements (100-200 kHz) were made by using this method. We also conducted simulations to compare LSCA with a moment analysis technique under a low photon count condition. Both experimental and synthetic measurements demonstrate the effectiveness of LSCA.

  7. Generalized emittance measurements in a beam transport line

    International Nuclear Information System (INIS)

    Skelly, J.; Gardner, C.; Luccio, A.; Kponou, A.; Reece, K.

    1991-01-01

    Motivated by the need to commission 3 beam transport lines for the new AGS Booster project, we have developed a generalized emittance-measurement program; beam line specifics are entirely resident in data tables, not in program code. For instrumentation, the program requires one or more multi-wire profile monitors; one or multiple profiles are acquired from each monitor, corresponding to one or multiple tunes of the transport line. Emittances and Twiss parameters are calculated using generalized algorithms. The required matix descriptions of the beam optics are constructed by an on-line general beam modeling program. Design of the program, its algorithms, and initial experience with it will be described. 4 refs., 2 figs., 1 tab

  8. Measurement of magnetically insulated line voltage using a Thomson Parabola Charged Particle Analyser

    International Nuclear Information System (INIS)

    Stanley, T.D.; Stinnett, R.W.

    1981-01-01

    The absence of direct measurements of magnetically insulated line voltage necessitated reliance on inferred voltages based on theoretical calculation and current measurements. This paper presents some of the first direct measurements of magnetically insulated transmission line peak voltages. These measurements were made on the Sandia National Laboratories HydraMITE facility. The peak voltage is measured by observing the energy of negative ions produced at the line cathode and accelerated through the line voltage. The ion energy and the charge-to-mass ratio are measured using the Thomson Parabola mass spectrometry technique. This technique uses parallel E and B fields to deflect the ions. The deflected ions are detected using a microchannel plate coupled to a phosphor screen and photographic film. The Thomson Parabola results are compared to Faraday Cup measurements and to calculated voltages based on current measurements. In addition, the significance of observed positive ions is discussed

  9. Comparison of electric field exposure measurement methods under power lines

    International Nuclear Information System (INIS)

    Korpinen, L.; Kuisti, H.; Tarao, H.; Paeaekkoenen, R.; Elovaara, J.

    2014-01-01

    The object of the study was to investigate extremely low frequency (ELF) electric field exposure measurement methods under power lines. The authors compared two different methods under power lines: in Method A, the sensor was placed on a tripod; and Method B required the measurer to hold the meter horizontally so that the distance from him/her was at least 1.5 m. The study includes 20 measurements in three places under 400 kV power lines. The authors used two commercial three-axis meters, EFA-3 and EFA-300. In statistical analyses, they did not find significant differences between Methods A and B. However, in the future, it is important to take into account that measurement methods can, in some cases, influence ELF electric field measurement results, and it is important to report the methods used so that it is possible to repeat the measurements. (authors)

  10. Secondary beam line phase space measurement and modeling at LAMPF

    International Nuclear Information System (INIS)

    Floyd, R.; Harrison, J.; Macek, R.; Sanders, G.

    1979-01-01

    Hardware and software have been developed for precision on-line measurement and fitting of secondary beam line phase space parameters. A system consisting of three MWPC planes for measuring particle trajectories, in coincidence with a time-of-flight telescope and a range telescope for particle identification, has been interfaced to a computer. Software has been developed for on-line track reconstruction, application of experimental cuts, and fitting of two-dimensional phase space ellipses for each particle species. The measured distributions have been found to agree well with the predictions of the Monte Carlo program DECAY TURTLE. The fitted phase space ellipses are a useful input to optimization routines, such as TRANSPORT, used to search for superior tunes. Application of this system to the LAMPF Stopped Muon Channel is described

  11. Natural gas large volumes measurement: going for on-line custody transfer; Medicao de grandes volumes de gas natural: rumo a transferencia de custodia on-line

    Energy Technology Data Exchange (ETDEWEB)

    Mercon, Eduardo G.; Frisoli, Caetano [PETROBRAS Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil)

    2005-07-01

    This paper describes the structure of the natural gas flow measurement process in TRANSPETRO, and comments features and performance of existing or under-implantation equipment and systems, reviewing best practices and technology in use. This process runs through three interrelated segments: data flow measurement, strictly speaking; data transfer and acquisition; and data flow measurement certification (data consolidation to invoice). Initially, the work makes an approach to the data flow measurement segment, evaluating technical features of flow meters, and describing configurations and functions of the operating gas flow computers in TRANSPETRO's custody transfer stations. In this part it will also be presented the implantation of TRANSPETRO's system for gas chromatography data input on-line to flow computers. Further, in data transfer and acquisition, SCADA system technical aspects will be evaluated, considering communications protocols and programmable logic controllers functions in remote terminal units, and discussing their places in the measurement process. Additionally, TRANSPETRO's experience in data measurement certification tools is in discussion, as well as new upcoming tools and their potential features, from what new practices will be suggested. Finally, all the work has been conceived and carried out always aiming to the state-of-the-art technology in gas flow measurement: on-line custody transfer. (author)

  12. Transport measurements on superconducting YBa2Cu3O7-δ thin film lines

    International Nuclear Information System (INIS)

    Moeckly, B.H.; Lathrop, D.K.; Redinbo, G.F.; Russek, S.E.; Buhrman, R.A.

    1990-01-01

    Critical current densities, magnetic field response, and microwave response have been measured for laser ablated YBa 2 Cu 3 O 7-δ thin film lines on MgO and SrTiO 3 substrates. Films on SrTiO 3 have critical current densities > 1 x 10 6 A/cm 2 at 77 K and show uniform transport properties in lines of all sizes. Films on MgO have critical current densities which range between 10 2 and 10 6 A/cm 2 at 77 K and show considerable variation from device to device on the same chip. Narrow lines on MgO with low critical current densities show Josephson weak link structure which includes RSJ-like IV curves, microwave induced constant voltage steps, and a high sensitivity to magnetic field. The presence of the Josephson weak links if correlated with small amounts of misaligned grains in film on MgO

  13. SEAPODYM-LTL: a parsimonious zooplankton dynamic biomass model

    Science.gov (United States)

    Conchon, Anna; Lehodey, Patrick; Gehlen, Marion; Titaud, Olivier; Senina, Inna; Séférian, Roland

    2017-04-01

    Mesozooplankton organisms are of critical importance for the understanding of early life history of most fish stocks, as well as the nutrient cycles in the ocean. Ongoing climate change and the need for improved approaches to the management of living marine resources has driven recent advances in zooplankton modelling. The classical modeling approach tends to describe the whole biogeochemical and plankton cycle with increasing complexity. We propose here a different and parsimonious zooplankton dynamic biomass model (SEAPODYM-LTL) that is cost efficient and can be advantageously coupled with primary production estimated either from satellite derived ocean color data or biogeochemical models. In addition, the adjoint code of the model is developed allowing a robust optimization approach for estimating the few parameters of the model. In this study, we run the first optimization experiments using a global database of climatological zooplankton biomass data and we make a comparative analysis to assess the importance of resolution and primary production inputs on model fit to observations. We also compare SEAPODYM-LTL outputs to those produced by a more complex biogeochemical model (PISCES) but sharing the same physical forcings.

  14. Potential of on-line visible and near infrared spectroscopy for measurement of pH for deriving variable rate lime recommendations.

    Science.gov (United States)

    Tekin, Yücel; Kuang, Boyan; Mouazen, Abdul M

    2013-08-08

    This paper aims at exploring the potential of visible and near infrared (vis-NIR) spectroscopy for on-line measurement of soil pH, with the intention to produce variable rate lime recommendation maps. An on-line vis-NIR soil sensor set up to a frame was used in this study. Lime application maps, based on pH predicted by vis-NIR techniques, were compared with maps based on traditional lab-measured pH. The validation of the calibration model using off-line spectra provided excellent prediction accuracy of pH (R2 = 0.85, RMSEP = 0.18 and RPD = 2.52), as compared to very good accuracy obtained with the on-line measured spectra (R2 = 0.81, RMSEP = 0.20 and RPD = 2.14). On-line predicted pH of all points (e.g., 2,160) resulted in the largest overall field virtual lime requirement (1.404 t), as compared to those obtained with 16 validation points off-line prediction (0.28 t), on-line prediction (0.14 t) and laboratory reference measurement (0.48 t). The conclusion is that the vis-NIR spectroscopy can be successfully used for the prediction of soil pH and for deriving lime recommendations. The advantage of the on-line sensor over sampling with limited number of samples is that more detailed information about pH can be obtained, which is the reason for a higher but precise calculated lime recommendation rate.

  15. Potential of On-Line Visible and Near Infrared Spectroscopy for Measurement of pH for Deriving Variable Rate Lime Recommendations

    Directory of Open Access Journals (Sweden)

    Yücel Tekin

    2013-08-01

    Full Text Available This paper aims at exploring the potential of visible and near infrared (vis-NIR spectroscopy for on-line measurement of soil pH, with the intention to produce variable rate lime recommendation maps. An on-line vis-NIR soil sensor set up to a frame was used in this study. Lime application maps, based on pH predicted by vis-NIR techniques, were compared with maps based on traditional lab-measured pH. The validation of the calibration model using off-line spectra provided excellent prediction accuracy of pH (R2 = 0.85, RMSEP = 0.18 and RPD = 2.52, as compared to very good accuracy obtained with the on-line measured spectra (R2 = 0.81, RMSEP = 0.20 and RPD = 2.14. On-line predicted pH of all points (e.g., 2,160 resulted in the largest overall field virtual lime requirement (1.404 t, as compared to those obtained with 16 validation points off-line prediction (0.28 t, on-line prediction (0.14 t and laboratory reference measurement (0.48 t. The conclusion is that the vis-NIR spectroscopy can be successfully used for the prediction of soil pH and for deriving lime recommendations. The advantage of the on-line sensor over sampling with limited number of samples is that more detailed information about pH can be obtained, which is the reason for a higher but precise calculated lime recommendation rate.

  16. Data driven discrete-time parsimonious identification of a nonlinear state-space model for a weakly nonlinear system with short data record

    Science.gov (United States)

    Relan, Rishi; Tiels, Koen; Marconato, Anna; Dreesen, Philippe; Schoukens, Johan

    2018-05-01

    Many real world systems exhibit a quasi linear or weakly nonlinear behavior during normal operation, and a hard saturation effect for high peaks of the input signal. In this paper, a methodology to identify a parsimonious discrete-time nonlinear state space model (NLSS) for the nonlinear dynamical system with relatively short data record is proposed. The capability of the NLSS model structure is demonstrated by introducing two different initialisation schemes, one of them using multivariate polynomials. In addition, a method using first-order information of the multivariate polynomials and tensor decomposition is employed to obtain the parsimonious decoupled representation of the set of multivariate real polynomials estimated during the identification of NLSS model. Finally, the experimental verification of the model structure is done on the cascaded water-benchmark identification problem.

  17. Calibration Base Lines for Electronic Distance Measuring Instruments (EDMI)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A calibration base line (CBL) is a precisely measured, straight-line course of approximately 1,400 m used to calibrate Electronic Distance Measuring Instruments...

  18. Systematics and morphological evolution within the moss family Bryaceae: a comparison between parsimony and Bayesian methods for reconstruction of ancestral character states.

    Science.gov (United States)

    Pedersen, Niklas; Holyoak, David T; Newton, Angela E

    2007-06-01

    The Bryaceae are a large cosmopolitan moss family including genera of significant morphological and taxonomic complexity. Phylogenetic relationships within the Bryaceae were reconstructed based on DNA sequence data from all three genomic compartments. In addition, maximum parsimony and Bayesian inference were employed to reconstruct ancestral character states of 38 morphological plus four habitat characters and eight insertion/deletion events. The recovered phylogenetic patterns are generally in accord with previous phylogenies based on chloroplast DNA sequence data and three major clades are identified. The first clade comprises Bryum bornholmense, B. rubens, B. caespiticium, and Plagiobryum. This corroborates the hypothesis suggested by previous studies that several Bryum species are more closely related to Plagiobryum than to the core Bryum species. The second clade includes Acidodontium, Anomobryum, and Haplodontium, while the third clade contains the core Bryum species plus Imbribryum. Within the latter clade, B. subapiculatum and B. tenuisetum form the sister clade to Imbribryum. Reconstructions of ancestral character states under maximum parsimony and Bayesian inference suggest fourteen morphological synapomorphies for the ingroup and synapomorphies are detected for most clades within the ingroup. Maximum parsimony and Bayesian reconstructions of ancestral character states are mostly congruent although Bayesian inference shows that the posterior probability of ancestral character states may decrease dramatically when node support is taken into account. Bayesian inference also indicates that reconstructions may be ambiguous at internal nodes for highly polymorphic characters.

  19. Measurement-Based Transmission Line Parameter Estimation with Adaptive Data Selection Scheme

    DEFF Research Database (Denmark)

    Li, Changgang; Zhang, Yaping; Zhang, Hengxu

    2017-01-01

    Accurate parameters of transmission lines are critical for power system operation and control decision making. Transmission line parameter estimation based on measured data is an effective way to enhance the validity of the parameters. This paper proposes a multi-point transmission line parameter...

  20. Stark broadening measurements of Xe III spectral lines

    International Nuclear Information System (INIS)

    Pelaez, R J; Cirisan, M; Djurovic, S; Aparicio, J A; Mar, S

    2006-01-01

    This work reports measured Stark widths of doubly ionized xenon lines. Pulsed arc was used as a plasma source. Measured electron densities and temperatures were in the ranges of (0.2 - 1.6) x 10 23 m -3 and 18 300-25 500 K, respectively. Stark halfwidths of lines from 6s-6p, 6s-4f and 5d-6p transitions have been measured and compared with available experimental and theoretical data

  1. Impact of SSSC on Measured Impedance in Single Phase to Ground Fault Condition on 220 kV Transmission Line

    Directory of Open Access Journals (Sweden)

    Mohamed ZELLAGUI

    2012-08-01

    Full Text Available This paper presents and compares the impact of SSSC on measured impedance for single phase to ground fault condition. The presence of Static Synchronous SSSC on a transmission line has a great influence on the ZRelay in distance protection. The protection of the high voltage 220 kV single circuit transmission line in eastern Algerian electrical transmission networks is affected in the case with resistance fault RF. The paper investigate the effect of Static Synchronous Series Compensator (SSSC on the measured impedance (Relay taking into account the distance fault point (n and fault resistance (RF. The resultants simulation is performed in MATLAB software environment.

  2. Seeing the elephant: Parsimony, functionalism, and the emergent design of contempt and other sentiments.

    Science.gov (United States)

    Gervais, Matthew M; Fessler, Daniel M T

    2017-01-01

    The target article argues that contempt is a sentiment, and that sentiments are the deep structure of social affect. The 26 commentaries meet these claims with a range of exciting extensions and applications, as well as critiques. Most significantly, we reply that construction and emergence are necessary for, not incompatible with, evolved design, while parsimony requires explanatory adequacy and predictive accuracy, not mere simplicity.

  3. Line Profile Measurements of the Lunar Exospheric Sodium

    Science.gov (United States)

    Oliversen, Ronald J.; Mierkiewicz, Edwin J.; Line, Michael R.; Roesler, Fred L.; Lupie, Olivia L.

    2012-01-01

    We report ongoing results of a program to measure the lunar sodium exospheric line profile from near the lunar limb out to two lunar radii (approx 3500 km). These observations are conducted from the National Solar Observatory McMath-Pierce telescope using a dual-etalon Fabry-Perot spectrometer with a resolving power of 180,600 (1.7 km/s) to measure line widths and velocity shifts of the Na D2 (5889 950 A) emission line in equatorial and polar regions at different lunar phases. The typical field of view (FOV) is 3 arcmin (approx 360 km) with an occasional smaller 1 arcmin FOV used right at the limb edge. The first data were obtained from full Moon to 3 days following full Moon (waning phase) in March 2009 as part of a demonstration run aimed at establishing techniques for a thorough study of temperatures and velocity variations in the lunar sodium exosphere. These data indicate velocity displacements from different locations off the lunar limb range between 150 and 600 m/s from the lunar rest velocity with a precision of +/- 20 to +/- 50 m/s depending on brightness. The measured Doppler line widths for observations within 10.5 arcmin of the east and south lunar limbs for observations between 5 deg and 40 deg lunar phase imply temperatures ranging decreasing from 3250 +/- 260K to 1175 +/- 150K. Additional data is now being collected on a quarterly basis since March 2011 and preliminary results will be reported.

  4. Measurements of residual deformations of steel-aluminum conductors in operating overhead lines

    Energy Technology Data Exchange (ETDEWEB)

    Durov, E.V.; Kesel' man, L.M.; Treiger, A.S.

    1982-12-01

    Experience in the operation of overhead power lines using steel-aluminum conductors is presented. Measurements were taken on the residual deformation of the steel-aluminum lines to determine the amount of sag increase and to forecast this increase for the entire period of operation. It is recommended that the work on measuring the residual deformation in the power lines be extended to a broader range of operating conditions such as conductors, spans, and climate conditions.

  5. Interferometric measurement of lines shift in flames in connection with interpretation of lined absorption method in atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    L'vov, B.V.; Polzik, L.K.; Katskov, D.A.; Kruglikova, L.P.

    1975-01-01

    This paper is concerned with interferometric measuring of the line shift in flames in the view of interpretation of absorption lines in the atomic absorption spectroscopy. The newly measured line shifts were compared to the known data on Lorentz broadening of the same lines obtained by methods free of the systematic errors. The resonant lines of the alkaline earth elements (Sr, Ca, Ba) were investigated. To reduce self-absorption in the flame the solutions with minimum concentrations of the elements were used. The computation scheme includes the spectrometer apparatus width and line broadening due to the self-absorption. Formulae are given for computing the values studied. Good agreement was observed between the computed and experimental results. Error analysis was performed. It was concluded that any line shifts in the hydrocarbons were correctly taken into an account in the absolute computations of absorption

  6. Hide and vanish: data sets where the most parsimonious tree is known but hard to find, and their implications for tree search methods.

    Science.gov (United States)

    Goloboff, Pablo A

    2014-10-01

    Three different types of data sets, for which the uniquely most parsimonious tree can be known exactly but is hard to find with heuristic tree search methods, are studied. Tree searches are complicated more by the shape of the tree landscape (i.e. the distribution of homoplasy on different trees) than by the sheer abundance of homoplasy or character conflict. Data sets of Type 1 are those constructed by Radel et al. (2013). Data sets of Type 2 present a very rugged landscape, with narrow peaks and valleys, but relatively low amounts of homoplasy. For such a tree landscape, subjecting the trees to TBR and saving suboptimal trees produces much better results when the sequence of clipping for the tree branches is randomized instead of fixed. An unexpected finding for data sets of Types 1 and 2 is that starting a search from a random tree instead of a random addition sequence Wagner tree may increase the probability that the search finds the most parsimonious tree; a small artificial example where these probabilities can be calculated exactly is presented. Data sets of Type 3, the most difficult data sets studied here, comprise only congruent characters, and a single island with only one most parsimonious tree. Even if there is a single island, missing entries create a very flat landscape which is difficult to traverse with tree search algorithms because the number of equally parsimonious trees that need to be saved and swapped to effectively move around the plateaus is too large. Minor modifications of the parameters of tree drifting, ratchet, and sectorial searches allow travelling around these plateaus much more efficiently than saving and swapping large numbers of equally parsimonious trees with TBR. For these data sets, two new related criteria for selecting taxon addition sequences in Wagner trees (the "selected" and "informative" addition sequences) produce much better results than the standard random or closest addition sequences. These new methods for Wagner

  7. Real-time line-width measurements: a new feature for reticle inspection systems

    Science.gov (United States)

    Eran, Yair; Greenberg, Gad; Joseph, Amnon; Lustig, Cornel; Mizrahi, Eyal

    1997-07-01

    The significance of line width control in mask production has become greater with the lessening of defect size. There are two conventional methods used for controlling line widths dimensions which employed in the manufacturing of masks for sub micron devices. These two methods are the critical dimensions (CD) measurement and the detection of edge defects. Achieving reliable and accurate control of line width errors is one of the most challenging tasks in mask production. Neither of the two methods cited above (namely CD measurement and the detection of edge defects) guarantees the detection of line width errors with good sensitivity over the whole mask area. This stems from the fact that CD measurement provides only statistical data on the mask features whereas applying edge defect detection method checks defects on each edge by itself, and does not supply information on the combined result of error detection on two adjacent edges. For example, a combination of a small edge defect together with a CD non- uniformity which are both within the allowed tolerance, may yield a significant line width error, which will not be detected using the conventional methods (see figure 1). A new approach for the detection of line width errors which overcomes this difficulty is presented. Based on this approach, a new sensitive line width error detector was developed and added to Orbot's RT-8000 die-to-database reticle inspection system. This innovative detector operates continuously during the mask inspection process and scans (inspects) the entire area of the reticle for line width errors. The detection is based on a comparison of measured line width that are taken on both the design database and the scanned image of the reticle. In section 2, the motivation for developing this new detector is presented. The section covers an analysis of various defect types, which are difficult to detect using conventional edge detection methods or, alternatively, CD measurements. In section 3

  8. Scatterometry measurement of nested lines, dual space, and rectangular contact CD on phase-shift masks

    Science.gov (United States)

    Lee, Kyung M.; Yedur, Sanjay; Henrichs, Sven; Tavassoli, Malahat; Baik, Kiho

    2007-03-01

    Evaluation of lithography process or stepper involves very large quantity of CD measurements and measurement time. In this paper, we report on a application of Scatterometry based metrology for evaluation of binary photomask lithography. Measurements were made on mask level with ODP scatterometer then on wafer with CD-SEM. 4 to 1 scaling from mask to wafer means 60nm line on wafer translates to 240nm on mask, easily measurable on ODP. Calculation of scatterometer profile information was performed by a in-situ library-based analysis (5sec/site). We characterized the CD uniformity, linearity, and metal film thickness uniformity. Results show that linearity measured from fixed-pitch, varying line/space ratio targets show good correlation to top-down CD-SEM with R2 of more than 0.99. ODP-SEM correlation results for variable pitch shows that careful examination of scatterometer profile results in order to obtain better correlation to CD SEM, since both tools react differently to the target profile variation. ODP results show that global CD distribution is clearly measurable with less outliers compared to CD SEM data. This is thought to be due to 'averaging' effect of scatterometer. The data show that Scatterometry provides a nondestructive and faster mean of characterizing lithography stepper performanceprofiles. APSM 1st level (before Cr removal) 'dual-space' CDs and EPSM rectangular contacts were also measured with and results demonstrates that Scatterometer is capable of measuring these targets with reasonable correlation to SEM.

  9. CORRELATION BETWEEN SOME BODY MEASURES OF LIPPIZANER STALLION PER LINES AT ĐAKOVO STUD

    Directory of Open Access Journals (Sweden)

    T. Rastija

    2002-06-01

    Full Text Available Body measures of Lippizaner line stallions and their correlation were processed in Đakovo stud. The measures performed by Lydtin rod and stock band included withers height, chest girth and cannon bone circumference on the total of 75 heads. Neapolitano line was characterized by the fewest number of stallions (4 whereas Tulip by the largest one (20. Data attained by the measuring were processed by the statistical program SPSS/PC (Nie et. al. 1975. Neapolitano line stallions had the lowest withers height (164.00 cm measured by the band whereas Conversano line stallions had the highest one (166.33 cm. Withers height measured by the rod was the lowest in the Maestoso line stallion (156.50 cm and the highest one in the Favory line (159.20 cm. Chest girth ranged between 183.82 cm (Pluto line and 186.89 cm (Conversano line. Cannon bone circumference was uniform with all lines ranged from 20.05 cm (Tulipan line and 20.65 cm (Maestoso lines. Correlation between withers height measured by the band and rod and that one measured by the rod and chest girth was positive and highly significant. However, correlation between others ranged from slight positive to slight negative. Neapolitano line was known for the most pronounced correlation per lines whereas Tulip line for the weakest one. Correlation between withers height measured by the band and rod was in all lines highly significant (except Tulip line whereas other correlation varied from positive to negative.

  10. Pengintegrasian Model Leadership Menuju Model yang Lebih Komprhensip dan Parsimoni

    Directory of Open Access Journals (Sweden)

    Miswanto Miswanti

    2016-06-01

    Full Text Available ABTSRACT Through leadership models offered by Locke et. al (1991 we can say that whether good or not the vision of leaders in the organization is highly dependent on whether good or not the motives and traits, knowledge, skill, and abilities owned leaders. Then, good or not the implementation of the vision by the leader depends on whether good or not the motives and traits, knowledge, skills, abilities, and the vision of the leaders. Strategic Leadership written by Davies (1991 states that the implementation of the vision by using strategic leadership, the meaning is much more complete than what has been written by Locke et. al. in the fourth stage of leadership. Thus, aspects of the implementation of the vision by Locke et al (1991 it is not complete implementation of the vision according to Davies (1991. With the considerations mentioned above, this article attempts to combine the leadership model of the Locke et. al and strategic leadership of the Davies. With this modification is expected to be an improvement model of leadership is more comprehensive and parsimony.

  11. Material Control and Accountability Measurements for FB-Line Processes

    International Nuclear Information System (INIS)

    Casella, V.R.

    2002-01-01

    This report provides an overview of FB-Line processes and nuclear material accountability measurements. Flow diagrams for the product, waste, and packaging and stabilization processes are given along with the accountability measurements done before and after each of these processes. Brief descriptions of these measurements are provided. This information provides a better understanding of the general FB-Line processes and how MC and A measurements are used to keep track of the accountable material inventory

  12. Parsimonious model for blood glucose level monitoring in type 2 diabetes patients.

    Science.gov (United States)

    Zhao, Fang; Ma, Yan Fen; Wen, Jing Xiao; DU, Yan Fang; Li, Chun Lin; Li, Guang Wei

    2014-07-01

    To establish the parsimonious model for blood glucose monitoring in patients with type 2 diabetes receiving oral hypoglycemic agent treatment. One hundred and fifty-nine adult Chinese type 2 diabetes patients were randomized to receive rapid-acting or sustained-release gliclazide therapy for 12 weeks. Their blood glucose levels were measured at 10 time points in a 24 h period before and after treatment, and the 24 h mean blood glucose levels were measured. Contribution of blood glucose levels to the mean blood glucose level and HbA1c was assessed by multiple regression analysis. The correlation coefficients of blood glucose level measured at 10 time points to the daily MBG were 0.58-0.74 and 0.59-0.79, respectively, before and after treatment (Pblood glucose levels measured at 6 of the 10 time points could explain 95% and 97% of the changes in MBG before and after treatment. The three blood glucose levels, which were measured at fasting, 2 h after breakfast and before dinner, of the 10 time points could explain 84% and 86% of the changes in MBG before and after treatment, but could only explain 36% and 26% of the changes in HbA1c before and after treatment, and they had a poorer correlation with the HbA1c than with the 24 h MBG. The blood glucose levels measured at fasting, 2 h after breakfast and before dinner truly reflected the change 24 h blood glucose level, suggesting that they are appropriate for the self-monitoring of blood glucose levels in diabetes patients receiving oral anti-diabetes therapy. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  13. Direct measurement of friction of a fluctuating contact line.

    Science.gov (United States)

    Guo, Shuo; Gao, Min; Xiong, Xiaomin; Wang, Yong Jian; Wang, Xiaoping; Sheng, Ping; Tong, Penger

    2013-07-12

    We report a direct measurement of the friction coefficient of a fluctuating (and slipping) contact line using a thin vertical glass fiber of diameter d with one end glued onto a cantilever beam and the other end touching a liquid-air interface. By measuring the broadening of the resonant peak of the cantilever system with varying liquid viscosity η, we find the friction coefficient of the contact line has a universal form, ξ(c)≃0.8πdη, independent of the liquid-solid contact angle. The obtained scaling law is further supported by the numerical simulation based on the phase field model under the generalized Navier boundary conditions.

  14. Annular shape silver lined proportional counter for on-line pulsed neutron yield measurement

    International Nuclear Information System (INIS)

    Dighe, P.M.; Das, D.

    2015-01-01

    An annular shape silver lined proportional counter is developed to measure pulsed neutron radiation. The detector has 314 mm overall length and 235 mm overall diameter. The central cavity of 150 mm diameter and 200 mm length is used for placing the neutron source. Because of annular shape the detector covers >3π solid angle of the source. The detector has all welded construction. The detector is developed in two halves for easy mounting and demounting. Each half is an independent detector. Both the halves together give single neutron pulse calibration constant of 4.5×10 4 neutrons/shot count. The detector operates in proportional mode which gives enhanced working conditions in terms of dead time and operating range compared to Geiger Muller based neutron detectors

  15. HB-Line Material Control and Accountability Measurements at SRS

    International Nuclear Information System (INIS)

    Casella, V.R.

    2003-01-01

    Presently, HB-Line work at the Savannah River Site consists primarily of the stabilization and packaging of nuclear materials for storage and the characterization of materials for disposition in H-Area. In order to ensure compliance with Material Control and Accountability (MC and A) Regulations, accountability measurements are performed throughout the HB-Line processes. Accountability measurements are used to keep track of the nuclear material inventory by constantly updating the amount of material in the MBAs (Material Balance Area) and sub-MBAs. This is done by subtracting the amount of accountable material that is added to a process and by adding the amount of accountable material that is put back in storage. A Physical Inventory is taken and compared to the ''Book Value'' listed in the Nuclear Material Accounting System. The difference (BPID) in the Book Inventory minus the Physical Inventory of a sub-account for bulk material must agree within the measurement errors combined in quadrature to provide assurance that nuclear material is accounted for. This work provides an overview of HB-Line processes and accountability measurements. The Scrap Recovery Line and Neptunium-237/Plutonium-239 Oxide Line are described and sampling and analyses for Phase II are provided. Recommendations for improvements are provided to improve efficiency and cost effectiveness

  16. On-line dry wood measurement in chips by nuclear means

    International Nuclear Information System (INIS)

    Oftedal, E.

    1978-01-01

    A system which has been installed and operating for two years in a Norwegian paper mill is described. It consists of a radiometric conveyor belt weighing instrument, a radiometric moisture guage and a data processor. The weighing instrument uses a cesium 137 source located above the conveyor belt with the radiation detector under the belt. The moisture gauge employs an americium-beryllium neutron source and a slow neutron detector, both placed above the belt. The data is processed and the moisture content calculated is continuously displayed. 4 analogue outputs are also available for automatic on-line process control. The results over a period of 20 months are shown, compared with results from laboratory measurements of samples. The two curves follow each other fairly closely. (JIW)

  17. On-line moisture analysis

    CERN Document Server

    Cutmore, N G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk mater...

  18. On the inversion problem of the plasma line intensity measurements in terms of photoelectron fluxes

    International Nuclear Information System (INIS)

    Lejeune, G.

    1979-01-01

    Assuming that the unidimensional distribution function of the photoelectron flux can be determined from plasma line intensity measurement, it is shown that the photoelectron flux distribution is not uniquely determined if additional hypotheses are not made. The limitations of the inversion procedure are shown: in particular, plasma line measurements cannot allow the determination of more than the first two Legendre components of the photoelectron flux. Experimental procedures for this determination are finally reviewed. (author)

  19. Program for large scanning-measuring table calibration on-line with the TRA-1001 computer

    International Nuclear Information System (INIS)

    Kalmykova, L.P.; Ososkov, G.A.; Pogodina, G.A.; Skryl', I.I.

    1975-01-01

    A description of a programme variant for complex calibration of the system of boards BPS-2, is given in which the stage of measurements and accumulation of calibration data is separated from that of data processing on CDC-1604A computers. Stage-by-stage calibration allows for simultaneous and parallel measurements on all the 6 boards. Such a possibility of the boards' operation on a computer-controlled line has been used as checking of the operators' actions with current control of the data obtained. Mathematical formulae are followed by programmes' descriptions. Reception and accumulation of coordinates of the units of the calibrating plate, with a highly precise net of straight lines, are accomplished with the help of the DATREC programme working on a guiding TPA-1001 computer with simultaneous calibration of all the six BPS-2 boards. The DATREC programme is written in the SLANG-1 language. The CALBPS programme works on CDC-1604A computer, is written in FORTRAN, and calculates transformation coefficients and corresponding precision characteristics. The work has resulted in reducing the calibration time from 10-15 min. per board to 10-15 min. per all the 6 boards. The time of accumulation in the memory TPA-1001 and of recording on the CDC-608 tape recorder of calibration data is from 3 to 5 min.; the remaining time is spent on processing on a bigger CDC-1604A computer. Examples of typical output and certain results of calibration measurements are given

  20. Accurate fault location algorithm on power transmission lines with use of two-end unsynchronized measurements

    Directory of Open Access Journals (Sweden)

    Mohamed Dine

    2012-01-01

    Full Text Available This paper presents a new approach to fault location on power transmission lines. This approach uses two-end unsynchronised measurements of the line and benefits from the advantages of digital technology and numerical relaying, which are available today and can easily be applied for off-line analysis. The approach is to modify the apparent impedance method using a very simple first-order formula. The new method is independent of fault resistance, source impedances and pre-fault currents. In addition, the data volume communicated between relays is sufficiently small enough to be transmitted easily using a digital protection channel. The proposed approach is tested via digital simulation using MATLand the applied test results corroborate the superior performance of the proposed approach.

  1. Maximum parsimony, substitution model, and probability phylogenetic trees.

    Science.gov (United States)

    Weng, J F; Thomas, D A; Mareels, I

    2011-01-01

    The problem of inferring phylogenies (phylogenetic trees) is one of the main problems in computational biology. There are three main methods for inferring phylogenies-Maximum Parsimony (MP), Distance Matrix (DM) and Maximum Likelihood (ML), of which the MP method is the most well-studied and popular method. In the MP method the optimization criterion is the number of substitutions of the nucleotides computed by the differences in the investigated nucleotide sequences. However, the MP method is often criticized as it only counts the substitutions observable at the current time and all the unobservable substitutions that really occur in the evolutionary history are omitted. In order to take into account the unobservable substitutions, some substitution models have been established and they are now widely used in the DM and ML methods but these substitution models cannot be used within the classical MP method. Recently the authors proposed a probability representation model for phylogenetic trees and the reconstructed trees in this model are called probability phylogenetic trees. One of the advantages of the probability representation model is that it can include a substitution model to infer phylogenetic trees based on the MP principle. In this paper we explain how to use a substitution model in the reconstruction of probability phylogenetic trees and show the advantage of this approach with examples.

  2. Study on on-Line Measurement and Controlling System of the Foundation Trench-Leveling Machine

    International Nuclear Information System (INIS)

    Yi, J G; Jiang, H Y; Xing, Y Z; Chen, J; Liu, J T

    2006-01-01

    Research the system software and hardware composing, the control mode, the online measurement and control principle based on the laser receiver and the inclination sensor as the signal source. After the laser receiver accepts the laser signal, the laser signal is carried through the light filter treatment so as to reduce the sunlight interference, and then amplified and modulated, last transmitted to the control unit. The inclination sensor adapts XWQJ02-01S, measure the slope angle the x and y verticality direction. The error adjusting range is ±0.05 0 . The separate time treatment avoids simultaneously adjusting the laser and inclination signal to each other interfere. The on-line measurement and control system realizes the parts to work on the plane that parallels with the datum plane of the laser beam scan. The trench-leveling machine must retain ±0.05 0 with the datum plane. Adapting the least square method to fit the linear curve, the movement trend of the work parts on the work plane is judged through the slope number. The test result shows that thought the combination measurement and control of the laser and slope angle the leveling precision are ±5mm/100. Its can satisfy with the construction criterion request

  3. New instrument for on-line viscosity measurement of fermentation media.

    Science.gov (United States)

    Picque, D; Corrieu, G

    1988-01-01

    In an attempt to resolve the difficult problem of on-line determination of the viscosity of non-Newtonian fermentation media, the authors have used a vibrating rod sensor mounted on a bioreactor. The sensor signal decreases nonlinearly with increased apparent viscosity. Electronic filtering of the signal damps the interfering effect of aeration and mechanical agitation. Sensor drift is very low (0.03% of measured value per hour). On the rheological level the sensor is primarily an empirical tool that must be specifically calibrated for each fermentation process. Once this is accomplished, it becomes possible to establish linear or second-degree correlations between the electrical signal from the sensor and the essential parameters of the fermentation process in question (pH of a fermented milk during acidification, concentration of extra cellular polysaccharide). In addition, by applying the power law to describe the rheological behavior of fermentation media, we observe a second-order polynomial correlation between the sensor signal and the behavior index (n).

  4. Effect of duct shape, Mach number, and lining construction on measured suppressor attenuation and comparison with theory

    Science.gov (United States)

    Olsen, W. A.; Krejsa, E. A.; Coats, J. W.

    1972-01-01

    Noise attenuation was measured for several types of cylindrical suppressors that use a duct lining composed of honeycomb cells covered with a perforated plate. The experimental technique used gave attenuation data that were repeatable and free of noise floors and other sources of error. The suppressor length, the effective acoustic diameter, suppressor shape and flow velocity were varied. The agreement among the attenuation data and two widely used analytical models was generally satisfactory. Changes were also made in the construction of the acoustic lining to measure their effect on attenuation. One of these produced a very broadband muffler.

  5. On-line tritium production and heat deposition rate measurements at the Lotus facility

    International Nuclear Information System (INIS)

    Joneja, O.P.; Scherrer, P.; Anand, R.P.

    1994-01-01

    Integral tritium production and heat deposition measurement in a prototype fusion blanket would enable verification of the computational codes and the data based employed for the calculations. A large number of tritium production rate measurements have been reported for different type of blankets, whereas the direct heat deposition due to the mixed radiation field in the fusion environment, is still in its infancy. In order to ascertain the kerma factors and the photon production libraries, suitable techniques must be developed to directly measure the nuclear heat deposition rates in the materials required for the fusion systems. In this context, at the Lotus facility, we have developed an extremely efficient double ionizing chamber, for the on-line tritium production measurements and employed a pure graphite calorimeter to measure the nuclear heat deposition due to the mixed radiation field of the 14 MeV, Haefely neutron generator. This paper presents both systems and some of the recent measurements. (authors). 8 refs., 13 figs

  6. Combination of On-line pH and Oxygen Transfer Rate Measurement in Shake Flasks by Fiber Optical Technique and Respiration Activity MOnitoring System (RAMOS

    Directory of Open Access Journals (Sweden)

    Jochen Büchs

    2007-12-01

    Full Text Available Shake flasks are commonly used for process development in biotechnologyindustry. For this purpose a lot of information is required from the growth conditions duringthe fermentation experiments. Therefore, Anderlei et al. developed the RAMOS technology[1, 2], which proviedes on-line oxygen and carbondioxide transfer rates in shake flasks.Besides oxygen consumption, the pH in the medium also plays an important role for thesuccessful cultivation of micro-organisms and for process development. For online pHmeasurement fiber optical methods based on fluorophores are available. Here a combinationof the on-line Oxygen Transfer Rate (OTR measurements in the RAMOS device with anon-line, fiber optical pH measurement is presented. To demonstrate the application of thecombined measurement techniques, Escherichia coli cultivations were performed and on-line pH measurements were compared with off-line samples. The combination of on-lineOTR and pH measurements gives a lot of information about the cultivation and, therefore, itis a powerful technique for monitoring shake flask experiments as well as for processdevelopment.

  7. Virtual sensors for on-line wheel wear and part roughness measurement in the grinding process.

    Science.gov (United States)

    Arriandiaga, Ander; Portillo, Eva; Sánchez, Jose A; Cabanes, Itziar; Pombo, Iñigo

    2014-05-19

    Grinding is an advanced machining process for the manufacturing of valuable complex and accurate parts for high added value sectors such as aerospace, wind generation, etc. Due to the extremely severe conditions inside grinding machines, critical process variables such as part surface finish or grinding wheel wear cannot be easily and cheaply measured on-line. In this paper a virtual sensor for on-line monitoring of those variables is presented. The sensor is based on the modelling ability of Artificial Neural Networks (ANNs) for stochastic and non-linear processes such as grinding; the selected architecture is the Layer-Recurrent neural network. The sensor makes use of the relation between the variables to be measured and power consumption in the wheel spindle, which can be easily measured. A sensor calibration methodology is presented, and the levels of error that can be expected are discussed. Validation of the new sensor is carried out by comparing the sensor's results with actual measurements carried out in an industrial grinding machine. Results show excellent estimation performance for both wheel wear and surface roughness. In the case of wheel wear, the absolute error is within the range of microns (average value 32 μm). In the case of surface finish, the absolute error is well below Ra 1 μm (average value 0.32 μm). The present approach can be easily generalized to other grinding operations.

  8. A system for accurate on-line measurement of total gas consumption or production rates in microbioreactors

    NARCIS (Netherlands)

    van Leeuwen, Michiel; Heijnen, Joseph J.; Gardeniers, Johannes G.E.; Oudshoorn, Arthur; Noorman, Henk; Visser, Jan; van der Wielen, Luuk A.M.; van Gulik, Walter M.

    2009-01-01

    A system has been developed, based on pressure controlled gas pumping, for accurate measurement of total gas consumption or production rates in the nmol/min range, applicable for on-line monitoring of bioconversions in microbioreactors. The system was validated by carrying out a bioconversion with

  9. New measurement system for on line in core high-energy neutron flux monitoring in materials testing reactor conditions

    International Nuclear Information System (INIS)

    Geslot, B.; Filliatre, P.; Barbot, L.; Jammes, C.; Breaud, S.; Oriol, L.; Villard, J.-F.; Vermeeren, L.; Lopez, A. Legrand

    2011-01-01

    Flux monitoring is of great interest for experimental studies in material testing reactors. Nowadays, only the thermal neutron flux can be monitored on line, e.g., using fission chambers or self-powered neutron detectors. In the framework of the Joint Instrumentation Laboratory between SCK-CEN and CEA, we have developed a fast neutron detector system (FNDS) capable of measuring on line the local high-energy neutron flux in fission reactor core and reflector locations. FNDS is based on fission chambers measurements in Campbelling mode. The system consists of two detectors, one detector being mainly sensitive to fast neutrons and the other one to thermal neutrons. On line data processing uses the CEA depletion code DARWIN in order to disentangle fast and thermal neutrons components, taking into account the isotopic evolution of the fissile deposit. The first results of FNDS experimental test in the BR2 reactor are presented in this paper. Several fission chambers have been irradiated up to a fluence of about 7 x 10 20 n/cm 2 . A good agreement (less than 10% discrepancy) was observed between FNDS fast flux estimation and reference flux measurement.

  10. New measurement system for on line in core high-energy neutron flux monitoring in materials testing reactor conditions

    Science.gov (United States)

    Geslot, B.; Vermeeren, L.; Filliatre, P.; Lopez, A. Legrand; Barbot, L.; Jammes, C.; Bréaud, S.; Oriol, L.; Villard, J.-F.

    2011-03-01

    Flux monitoring is of great interest for experimental studies in material testing reactors. Nowadays, only the thermal neutron flux can be monitored on line, e.g., using fission chambers or self-powered neutron detectors. In the framework of the Joint Instrumentation Laboratory between SCK-CEN and CEA, we have developed a fast neutron detector system (FNDS) capable of measuring on line the local high-energy neutron flux in fission reactor core and reflector locations. FNDS is based on fission chambers measurements in Campbelling mode. The system consists of two detectors, one detector being mainly sensitive to fast neutrons and the other one to thermal neutrons. On line data processing uses the CEA depletion code DARWIN in order to disentangle fast and thermal neutrons components, taking into account the isotopic evolution of the fissile deposit. The first results of FNDS experimental test in the BR2 reactor are presented in this paper. Several fission chambers have been irradiated up to a fluence of about 7 × 1020 n/cm2. A good agreement (less than 10% discrepancy) was observed between FNDS fast flux estimation and reference flux measurement.

  11. New measurement system for on line in core high-energy neutron flux monitoring in materials testing reactor conditions

    Energy Technology Data Exchange (ETDEWEB)

    Geslot, B.; Filliatre, P.; Barbot, L.; Jammes, C.; Breaud, S.; Oriol, L.; Villard, J.-F. [CEA, DEN, Cadarache, SPEx/LDCI, F-13108 Saint-Paul-lez-Durance (France); Vermeeren, L. [SCK-CEN, Boeretang 200, B-2400 Mol (Belgium); Lopez, A. Legrand [CEA, DEN, Saclay, SIREN/LECSI, F-91400 Saclay (France)

    2011-03-15

    Flux monitoring is of great interest for experimental studies in material testing reactors. Nowadays, only the thermal neutron flux can be monitored on line, e.g., using fission chambers or self-powered neutron detectors. In the framework of the Joint Instrumentation Laboratory between SCK-CEN and CEA, we have developed a fast neutron detector system (FNDS) capable of measuring on line the local high-energy neutron flux in fission reactor core and reflector locations. FNDS is based on fission chambers measurements in Campbelling mode. The system consists of two detectors, one detector being mainly sensitive to fast neutrons and the other one to thermal neutrons. On line data processing uses the CEA depletion code DARWIN in order to disentangle fast and thermal neutrons components, taking into account the isotopic evolution of the fissile deposit. The first results of FNDS experimental test in the BR2 reactor are presented in this paper. Several fission chambers have been irradiated up to a fluence of about 7 x 10{sup 20} n/cm{sup 2}. A good agreement (less than 10% discrepancy) was observed between FNDS fast flux estimation and reference flux measurement.

  12. Argon line broadening by neutral atoms and application to the measurement of oscillator strengths of AI resonance lines

    International Nuclear Information System (INIS)

    Vallee, O.; Ranson, P.; Chapelle, J.

    1977-01-01

    AI line broadening was studied from collisions between neutral argon atoms (3p 5 4p-3p 5 4s transitions) in a weakly ionised plasma jet (neutral atoms temperature T 0 approximately 4000K, electrons temperature Tsub(e) approximately 6000K, electronic density Nsub(e) 15 cm -3 , ionisation rate α -4 , and pressure range from 1 to 3 kg/cm 2 ). A satisfactory description of Van der Waals broadened lines is obtained by means of a Lennard-Jones potential. Measurement of line widths whose corresponding transitions occur on resonant levels, gives with relatively good accuracy the oscillator strength of the argon resonance lines [fr

  13. Measurement of X-ray emission efficiency for K-lines.

    Science.gov (United States)

    Procop, M

    2004-08-01

    Results for the X-ray emission efficiency (counts per C per sr) of K-lines for selected elements (C, Al, Si, Ti, Cu, Ge) and for the first time also for compounds and alloys (SiC, GaP, AlCu, TiAlC) are presented. An energy dispersive X-ray spectrometer (EDS) of known detection efficiency (counts per photon) has been used to record the spectra at a takeoff angle of 25 degrees determined by the geometry of the secondary electron microscope's specimen chamber. Overall uncertainty in measurement could be reduced to 5 to 10% in dependence on the line intensity and energy. Measured emission efficiencies have been compared with calculated efficiencies based on models applied in standardless analysis. The widespread XPP and PROZA models give somewhat too low emission efficiencies. The best agreement between measured and calculated efficiencies could be achieved by replacing in the modular PROZA96 model the original expression for the ionization cross section by the formula given by Casnati et al. (1982) A discrepancy remains for carbon, probably due to the high overvoltage ratio.

  14. Bayesian, Maximum Parsimony and UPGMA Models for Inferring the Phylogenies of Antelopes Using Mitochondrial Markers

    OpenAIRE

    Khan, Haseeb A.; Arif, Ibrahim A.; Bahkali, Ali H.; Al Farhan, Ahmad H.; Al Homaidan, Ali A.

    2008-01-01

    This investigation was aimed to compare the inference of antelope phylogenies resulting from the 16S rRNA, cytochrome-b (cyt-b) and d-loop segments of mitochondrial DNA using three different computational models including Bayesian (BA), maximum parsimony (MP) and unweighted pair group method with arithmetic mean (UPGMA). The respective nucleotide sequences of three Oryx species (Oryx leucoryx, Oryx dammah and Oryx gazella) and an out-group (Addax nasomaculatus) were aligned and subjected to B...

  15. Jet outflow and open field line measurements on the C-2U advanced beam-driven field-reversed configuration plasma experiment.

    Science.gov (United States)

    Sheftman, D; Gupta, D; Roche, T; Thompson, M C; Giammanco, F; Conti, F; Marsili, P; Moreno, C D

    2016-11-01

    Knowledge and control of the axial outflow of plasma particles and energy along open-magnetic-field lines are of crucial importance to the stability and longevity of the advanced beam-driven field-reversed configuration plasma. An overview of the diagnostic methods used to perform measurements on the open field line plasma on C-2U is presented, including passive Doppler impurity spectroscopy, microwave interferometry, and triple Langmuir probe measurements. Results of these measurements provide the jet ion temperature and axial velocity, electron density, and high frequency density fluctuations.

  16. Expert System Development on On-line Measurement of Sewage Treatment Based Process

    Directory of Open Access Journals (Sweden)

    Jianjun QIN

    2014-02-01

    Full Text Available This article puts forward a solution in which an instrument on-line automatic measurement and expert system process are optimized according to the complexity and great process dynamics of sewage treatment process. Firstly modeling has been set up with configuration sewage treatment process in which the process has been integrated into the computer software environment. Secondly certain number of water quality automatic monitoring instruments and sensor probes are set in the reaction tanks according to the needs of process changes and management. The data information acquired can be displayed and recorded at the real time. A human-machine integration expert system featuring computer automation management is developed for the base by one-off method thus to realize the intelligent and unmanned management. The advantages brought about from it can fill up the inexperience of the on-site management personnel and solve the contradiction between the water quality dynamics and difficulty in the process adjustment.

  17. AMS Ground Truth Measurements: Calibration and Test Lines

    International Nuclear Information System (INIS)

    Wasiolek, P.

    2013-01-01

    Airborne gamma spectrometry is one of the primary techniques used to define the extent of ground contamination after a radiological incident. Its usefulness was demonstrated extensively during the response to the Fukushima nuclear power plant (NPP) accident in March-May 2011. To map ground contamination a set of scintillation detectors is mounted on an airborne platform (airplane or helicopter) and flown over contaminated areas. The acquisition system collects spectral information together with the aircraft position and altitude every second. To provide useful information to decision makers, the count rate data expressed in counts per second (cps) needs to be converted to the terrestrial component of the exposure rate 1 m above ground, or surface activity of isotopes of concern. This is done using conversion coefficients derived from calibration flights. During a large scale radiological event, multiple flights may be necessary and may require use of assets from different agencies. However, as the production of a single, consistent map product depicting the ground contamination is the primary goal, it is critical to establish very early into the event a common calibration line. Such a line should be flown periodically in order to normalize data collected from different aerial acquisition systems and potentially flown at different flight altitudes and speeds. In order to verify and validate individual aerial systems, the calibration line needs to be characterized in terms of ground truth measurements. This is especially important if the contamination is due to short-lived radionuclides. The process of establishing such a line, as well as necessary ground truth measurements, is described in this document.

  18. AMS Ground Truth Measurements: Calibrations and Test Lines

    Energy Technology Data Exchange (ETDEWEB)

    Wasiolek, Piotr T. [National Security Technologies, LLC

    2015-12-01

    Airborne gamma spectrometry is one of the primary techniques used to define the extent of ground contamination after a radiological incident. Its usefulness was demonstrated extensively during the response to the Fukushima NPP accident in March-May 2011. To map ground contamination, a set of scintillation detectors is mounted on an airborne platform (airplane or helicopter) and flown over contaminated areas. The acquisition system collects spectral information together with the aircraft position and altitude every second. To provide useful information to decision makers, the count data, expressed in counts per second (cps), need to be converted to a terrestrial component of the exposure rate at 1 meter (m) above ground, or surface activity of the isotopes of concern. This is done using conversion coefficients derived from calibration flights. During a large-scale radiological event, multiple flights may be necessary and may require use of assets from different agencies. However, because production of a single, consistent map product depicting the ground contamination is the primary goal, it is critical to establish a common calibration line very early into the event. Such a line should be flown periodically in order to normalize data collected from different aerial acquisition systems and that are potentially flown at different flight altitudes and speeds. In order to verify and validate individual aerial systems, the calibration line needs to be characterized in terms of ground truth measurements This is especially important if the contamination is due to short-lived radionuclides. The process of establishing such a line, as well as necessary ground truth measurements, is described in this document.

  19. An evaluation of measurement uncertainties in the on-line measurement of coal ash content by gamma-ray transmission

    International Nuclear Information System (INIS)

    Wenzhong, Liu; Li, Kong; Tan, Qu; Jingjing, Cheng

    2002-01-01

    In this paper, a significant effect producing systematic errors in the on-line measurement using gamma-ray transmission is revealed. Ash content fluctuations or thickness changes lead to a permanent negative systematic error in the results of the measurements. To study uncertainties in the measurements applicable to time-independent ash content indicators and to investigate the characteristics of the radiation attenuation process, the behavior of the quantity in question is modeled with a stationary Gaussian distribution. A systematic error-producing effect has been found, and a quantitative correction is given to compensate for it. For some other quantities in question that vary in time, a linear model is used to discuss the systematic errors in the case of automated coal gangue separator. Results of experiments that demonstrate different systematic errors for different sampling intervals are presented. The reason for these errors is the nonlinearity of the relationship between the radiation intensity, on the one hand, and the sample thickness and mass attention, on the other

  20. Measuring MFT's Mental Health Literacy and Competence: The Effects of an On-Line Introductory Workshop on Eating Disorders

    Science.gov (United States)

    Beck-Ellsworth, Danielle

    2011-01-01

    Purpose of study: The purpose of the validity study was to establish known-groups validity of the two measures used for the main study by comparing the responses of the Eating Disorder experts and non-experts. The purpose of the main study was to develop an on-line introductory workshop on eating disorders and investigate the levels of competency…

  1. Statistical evaluation and measuring strategy for extremely small line shifts

    International Nuclear Information System (INIS)

    Hansen, P.G.

    1978-01-01

    For a measuring situation limited by counting statistics, but where the level of precision is such that possible systematic errors are a major concern, it is proposed to determine the position of a spectral line from a measured line segment by applying a bias correction to the centre of gravity of the segment. This procedure is statistically highly efficient and not sensitive to small errors in assumptions about the line shape. The counting strategy for an instrument that takes data point by point is also considered. It is shown that an optimum (''two-point'') strategy exists; a scan of the central part of the line is 68% efficient by this standard. (Auth.)

  2. Simultaneous influence of Stark effect and excessive line broadening on the Hα line

    Science.gov (United States)

    Cvetanović, Nikola; Ivković, Saša S.; Obradović, Bratislav M.; Kuraica, Milorad M.

    2017-12-01

    The aim of this paper is to study the combined influence of the Stark effect and the excessive Doppler broadening on the Balmer alpha line in hydrogen discharges. Since this line is a good candidate for measuring electric field in various types of discharges with different gas compositions, a simple method for field measurement based on polarization spectroscopy is developed, that includes all the excitation mechanisms. To simultaneously test the flexibility of the fitting procedure and investigate the excessive broadening, we applied the fitting procedure on line profiles obtained at a range of conditions from two different discharges. The range of pressures and voltages was examined in an abnormal glow and in dielectric barrier discharge operating with hydrogen gas. The model fitting function was able to respond and follow the change in the line profile caused by the change of conditions. This procedure can therefore be recommended for electric field measurement. Contribution to the "Topical Issue: Physics of Ionized Gases (SPIG 2016)", edited by Goran Poparic, Bratislav Obradovic, Dragana Maric and Aleksandar Milosavljevic.

  3. Stark shift measurements of Xe II and Xe III spectral lines

    International Nuclear Information System (INIS)

    Cirisan, M; Pelaez, R J; Djurovic, S; Aparicio, J A; Mar, S

    2007-01-01

    Stark shift measurements of singly and doubly ionized Xe spectral lines are presented in this paper. Shifts of 110 Xe II lines and 42 Xe III lines are reported, including a significant number of new results. A low-pressure-pulsed arc with 95% of He and 5% of Xe was used as a plasma source. All measurements were performed under the following plasma conditions: electron density (0.2-1.4) x 10 23 m -3 and electron temperature 18 000-23 000 K. The measured Stark shifts are compared with other experimental and theoretical data

  4. Temperature Measurements in the Solar Transition Region Using N III Line Intensity Ratios

    Science.gov (United States)

    Doron, R.; Doschek, G. A.; Laming, J. M.; Feldman, U.; Bhatia, A. K.

    2003-01-01

    UV emission from B-like N and O ions a rather rare opportunity for recording spectral lines in a narrow wavelength range that can potentially be used to derive temperatures relevant to the solar transition region. In these ions, the line intensity ratios of the type (2s2p(sup 2) - 2p(sup 3)) / (2s(sup 2)2p - 2s2p(sup 2)) are very sensitive to the electron temperature. Additionally, the lines involving the ratios fall within a range of only - 12 A; in N III the lines fall in the 980 - 992 A range and in O IV in the 780 - 791 A range. In this work, we explore the use of these atomic systems, primarily in N III, for temperature diagnostics of the transition region by analyzing UV spectra obtained by the Solar Ultraviolet Measurements of Emitted Radiation (SUMER) spectrometer flown on the Solar and Heliospheric Observatory (SOHO). The N III temperature-sensitive line ratios are measured in more than 60 observations. Most of the measured ratios correspond to temperatures in the range 5.7x10(exp 4) - 6.7x10(exp 4) K. This range is considerably lower than the calculated temperature of maximum abundance of N III, which is approx. 7.6x10(exp 4) K. Detailed analysis of the spectra further indicates that the measured ratios are probably somewhat overestimated due to resonant scattering effects in the 2s(sup 2)2p - 2s2p(sup 2) lines and small blends in the 2s2p(sup 2) - 2p3 lines. Actual lower ratios would only increase the disagreement between the ionization balance calculations and present temperature measurements based on a collisional excitation model. In the case of the O IV spectra, we determined that due to the close proximity in wavelength of the weak line (2s2p(sup 2)-2p3 transitions) to a strong Ne VIII line, sufficiently accurate ratio measurements cannot be obtained. Subject headings: atomic data --- atomic processes --- Sun: transition region --- Sun: U V radiation --- techniques: spectroscopic

  5. Influence Of Specific Mechanical Energy On Cornmeal Viscosity Measured By An On-line System During Twin-screw Extrusion

    OpenAIRE

    Chang Y.K.; Martinez-Bustos F.; Park T.S.; Kokini J.L.

    1999-01-01

    The influence of specific mechanical energy (SME) on cornmeal viscosity during the twin-screw extrusion at feed moisture contents of 25 and 30% and screw speeds in the range from 100 to 500 rpm was measured. Cornmeal was extruded in a co-rotating, intermeshing twin-screw coupled to a slit die rheometer. One approach to the on-line rheological measurement is to use a slit die with the extruder. In the present work it was show that shear viscosity decreased as a function of SME. The viscosity o...

  6. ELF field in the proximity of complex power line configuration measurement procedures

    International Nuclear Information System (INIS)

    Benes, M.; Comelli, M.; Villalta, R.

    2006-01-01

    The issue of how to measure magnetic induction fields generated by various power line configurations, when there are several power lines that run across the same exposure area, has become a matter of interest and study within the Regional Environment Protection Agency of Friuli Venezia Giulia. In classifying the various power line typologies the definition of double circuit line was given: in this instance the magnetic field is determined by knowing the electrical and geometric parameters of the line. In the case of independent lines instead, the field is undetermined. It is therefore pointed out how, in the latter case, extracting projected information from a set of measurements of the magnetic field alone is impossible. Making measurements throughout the territory of service has in several cases offered the opportunity to define standard operational procedures. (authors)

  7. Application of a chronoamperometric measurement to the on-line monitoring of a lithium metal reduction for uranium oxide

    International Nuclear Information System (INIS)

    Kim, Tack-Jin; Cho, Young-Hwan; Choi, In-Kyu; Kang, Jun-Gill; Song, Kyuseok; Jee, Kwang-Yong

    2008-01-01

    Both a potentiometric and a chronoamperometric electrochemical technique have been applied in an attempt to develop an efficient method for an on-line monitoring of a lithium metal reduction process of uranium oxides at a high-temperature in a molten salt medium. As a result of this study, it was concluded that the chronoamperometric method provided a simple and effective way for a direct on-line monitoring measurement of a lithium metal reduction process of uranium oxides at 650 o C by the measuring electrical currents dependency on a variation of the reduction time for the reaction. A potentiometric method, by adopting a homemade oxide ion selective electrode made of ZrO 2 stabilized by a Y 2 O 3 doping, however, was found to be inappropriate for an on-line monitoring of the reduction reaction of uranium oxide in the presence of lithium metal due to an abnormal behavior of the adopted electrodes. The observed experimental results were discussed in detail by comparing them with previously published experimental data

  8. LABORATORY MEASUREMENTS OF WHITE DWARF PHOTOSPHERIC SPECTRAL LINES: Hβ

    International Nuclear Information System (INIS)

    Falcon, Ross E.; Gomez, T. A.; Montgomery, M. H.; Winget, D. E.; Rochau, G. A.; Bailey, J. E.; Nagayama, T.

    2015-01-01

    We spectroscopically measure multiple hydrogen Balmer line profiles from laboratory plasmas to investigate the theoretical line profiles used in white dwarf (WD) atmosphere models. X-ray radiation produced at the Z Pulsed Power Facility at Sandia National Laboratories initiates plasma formation in a hydrogen-filled gas cell, replicating WD photospheric conditions. Here we present time-resolved measurements of Hβ and fit this line using different theoretical line profiles to diagnose electron density, n e , and n = 2 level population, n 2 . Aided by synthetic tests, we characterize the validity of our diagnostic method for this experimental platform. During a single experiment, we infer a continuous range of electron densities increasing from n e ∼ 4 to ∼30 × 10 16 cm −3 throughout a 120-ns evolution of our plasma. Also, we observe n 2 to be initially elevated with respect to local thermodynamic equilibrium (LTE); it then equilibrates within ∼55 ns to become consistent with LTE. This supports our electron-temperature determination of T e ∼ 1.3 eV (∼15,000 K) after this time. At n e ≳ 10 17 cm −3 , we find that computer-simulation-based line-profile calculations provide better fits (lower reduced χ 2 ) than the line profiles currently used in the WD astronomy community. The inferred conditions, however, are in good quantitative agreement. This work establishes an experimental foundation for the future investigation of relative shapes and strengths between different hydrogen Balmer lines

  9. Evaluation of self-absorption coefficients of aluminum emission lines in laser-induced breakdown spectroscopy measurements

    International Nuclear Information System (INIS)

    El Sherbini, A.M.; El Sherbini, Th.M.; Hegazy, H.; Cristoforetti, G.; Legnaioli, S.; Palleschi, V.; Pardini, L.; Salvetti, A.; Tognoni, E.

    2005-01-01

    In quantitative Laser Induced Breakdown Spectroscopy (LIBS) measurements it is essential to account for the effect of self-absorption on the emission lines intensity. In order to quantify this effect, in this paper we propose a simple method for evaluating the ratio between the actual measured line intensity and the intensity expected in absence of self-absorption and, if necessary, correcting the effect of self-absorption on line intensity. The method, based on a homogeneous plasma model, is applicable when the plasma electron density is known and in particular to lines whose Stark broadening parameter is available

  10. Selenium x-ray laser line profile measurements

    International Nuclear Information System (INIS)

    Koch, J.A.; MacGowan, B.J.; Da Silva, L.; Matthews, D.L.; Mrowka, S.; Underwood, J.H.; Batson, P.J.

    1992-01-01

    We discuss our recent measurements of the spectral width of the 206.38 Angstrom laser in Ne-like Se. These measurements were performed over a wide range of amplifier length indicate an intrinsic line width of 50 m Angstrom FWHM (full-width at half-maximum), show gain narrowing to 10 m Angstrom in intermediate length amplifiers and show no significant re-broadening in We briefly discuss the experiments and interpretations

  11. An on-line monitoring system for navigation equipment

    Science.gov (United States)

    Wang, Bo; Yang, Ping; Liu, Jing; Yang, Zhengbo; Liang, Fei

    2017-10-01

    Civil air navigation equipment is the most important infrastructure of Civil Aviation, which is closely related to flight safety. In addition to regular flight inspection, navigation equipment's patrol measuring, maintenance measuring, running measuring under special weather conditions are the important means of ensuring aviation flight safety. According to the safety maintenance requirements of Civil Aviation Air Traffic Control navigation equipment, this paper developed one on-line monitoring system with independent intellectual property rights for navigation equipment, the system breakthroughs the key technologies of measuring navigation equipment on-line including Instrument Landing System (ILS) and VHF Omni-directional Range (VOR), which also meets the requirements of navigation equipment ground measurement set by the ICAO DOC 8071, it provides technical means of the ground on-line measurement for navigation equipment, improves the safety of navigation equipment operation, and reduces the impact of measuring navigation equipment on airport operation.

  12. The split-cross-bridge resistor for measuring the sheet resistance, linewidth, and line spacing of conducting layers

    Science.gov (United States)

    Buehler, M. G.; Hershey, C. W.

    1986-01-01

    A new test structure was developed for evaluating the line spacing between conductors on the same layer using an electrical measurement technique. This compact structure can also be used to measure the sheet resistance, linewidth, and line pitch of the conducting layer. Using an integrated-circuit fabrication process, this structure was fabricated in diffused polycrystalline silicon and metal layers and measured optically and electrically. For the techniques used, the optical measurements were typically one-quarter micron greater than the electrical measurements. Most electrically measured line pitch values were within 2 percent of the designed value. A small difference between the measured and designed line pitch is used to validate sheet resistance, linewidth, and line spacing values.

  13. Balancing practicality and hydrologic realism: a parsimonious approach for simulating rapid groundwater recharge via unsaturated-zone preferential flow

    Science.gov (United States)

    Mirus, Benjamin B.; Nimmo, J.R.

    2013-01-01

    The impact of preferential flow on recharge and contaminant transport poses a considerable challenge to water-resources management. Typical hydrologic models require extensive site characterization, but can underestimate fluxes when preferential flow is significant. A recently developed source-responsive model incorporates film-flow theory with conservation of mass to estimate unsaturated-zone preferential fluxes with readily available data. The term source-responsive describes the sensitivity of preferential flow in response to water availability at the source of input. We present the first rigorous tests of a parsimonious formulation for simulating water table fluctuations using two case studies, both in arid regions with thick unsaturated zones of fractured volcanic rock. Diffuse flow theory cannot adequately capture the observed water table responses at both sites; the source-responsive model is a viable alternative. We treat the active area fraction of preferential flow paths as a scaled function of water inputs at the land surface then calibrate the macropore density to fit observed water table rises. Unlike previous applications, we allow the characteristic film-flow velocity to vary, reflecting the lag time between source and deep water table responses. Analysis of model performance and parameter sensitivity for the two case studies underscores the importance of identifying thresholds for initiation of film flow in unsaturated rocks, and suggests that this parsimonious approach is potentially of great practical value.

  14. Time-Lapse Monitoring of Subsurface Fluid Flow using Parsimonious Seismic Interferometry

    KAUST Repository

    Hanafy, Sherif

    2017-04-21

    A typical small-scale seismic survey (such as 240 shot gathers) takes at least 16 working hours to be completed, which is a major obstacle in case of time-lapse monitoring experiments. This is especially true if the subject that needs to be monitored is rapidly changing. In this work, we will discuss how to decrease the recording time from 16 working hours to less than one hour of recording. Here, the virtual data has the same accuracy as the conventional data. We validate the efficacy of parsimonious seismic interferometry with the time-lapse mentoring idea with field examples, where we were able to record 30 different data sets within a 2-hour period. The recorded data are then processed to generate 30 snapshots that shows the spread of water from the ground surface down to a few meters.

  15. A new technique for on-line and off-line high speed computation

    International Nuclear Information System (INIS)

    Hartouni, E.P.; Jensen, D.A.; Klima, B.; Kreisler, M.N.; Rabin, M.S.Z.; Uribe, J.; Gottschalk, E.; Gara, A.; Knapp, B.C.

    1989-01-01

    A new technique for both on-line and off-line computation has been developed. With this technique, a reconstruction analysis in Elementary Particle Physics, otherwise prohibitively long, has been accomplished. It will be used on-line in an upcoming Fermilab experiment to reconstruct more than 100,000 events per second and to trigger on the basis of that information. The technique delivers 40 Giga operations per second, has a bandwidth on the order of Gigabytes per second and has a modest cost. An overview of the program, details of the system, and performance measurements are presented in this paper

  16. Effects of Goal Line Feedback on Level, Slope, and Stability of Performance within Curriculum-Based Measurement.

    Science.gov (United States)

    Fuchs, Lynn S.; And Others

    1991-01-01

    Nineteen special educators implemented Curriculum-Based Measurement with a total of 36 learning-disabled math pupils in grades 2-8 to examine the effects of goal line feedback. Results indicated comparable levels and slopes of student performance across treatment conditions, although goal line feedback was associated with greater performance…

  17. Composite scores in comparative effectiveness research: counterbalancing parsimony and dimensionality in patient-reported outcomes.

    Science.gov (United States)

    Schwartz, Carolyn E; Patrick, Donald L

    2014-07-01

    When planning a comparative effectiveness study comparing disease-modifying treatments, competing demands influence choice of outcomes. Current practice emphasizes parsimony, although understanding multidimensional treatment impact can help to personalize medical decision-making. We discuss both sides of this 'tug of war'. We discuss the assumptions, advantages and drawbacks of composite scores and multidimensional outcomes. We describe possible solutions to the multiple comparison problem, including conceptual hierarchy distinctions, statistical approaches, 'real-world' benchmarks of effectiveness and subgroup analysis. We conclude that comparative effectiveness research should consider multiple outcome dimensions and compare different approaches that fit the individual context of study objectives.

  18. Turbidimetric Measurement for On-line Monitoring of SiO2 Particles

    International Nuclear Information System (INIS)

    Kim, In Sook; Lim, H. B.; Kim, Yang Sun

    2004-01-01

    In this work, the fundamental study of on-line monitoring of SiO 2 particles in the size range of 40 nm to 725 nm was carried out using turbidimetry. The size of particle was measured using a field emission scanning electron microscope (FE-SEM). The factors affecting on the turbidity were discussed, for example, wavelength, size, and concentration. In order to observe the dependence of turbidity on the wavelength, a turbidimetric system equipped with charged coupled detector (CCD) was built. The shape of the transmitted peak was changed and the peak maximum was shifted to the red when the concentration of particle was increased. This result indicates that the turbidity is related to the wavelength, which corresponds to the characteristic of the Mie extinction coefficient, Q, that is a function of not only particle diameter and refractive index but also wavelength. It is clear that a linear calibration curve for each particle in different size can be obtained at an optimized wavelength

  19. Parsimonious data

    DEFF Research Database (Denmark)

    Kristensen, Jakob Baek; Albrechtsen, Thomas; Dahl-Nielsen, Emil

    2017-01-01

    This study shows how liking politicians’ public Facebook posts can be used as an accurate measure for predicting present-day voter intention in a multiparty system. We highlight that a few, but selective digital traces produce prediction accuracies that are on par or even greater than most curren...

  20. In-core program for on line measurements of neutron, photon and nuclear heating parameters inside Jules Horowitz MTR reactor

    International Nuclear Information System (INIS)

    Lyoussi, A.; Reynard-Carette, C.

    2014-01-01

    Accurate on-line measurements of key parameters inside experimental channels of Material Testing Reactor are necessary to dimension the irradiation devices and consequently to conduct smart experiments on fuels and materials under suitable conditions. In particular the quantification of nuclear heating, a relevant parameter to reach adapted thermal conditions, has to be improved. These works focus on an important collaborative program between CEA and Aix-Marseille University called INCORE (Instrumentation for Nuclear radiations and Calorimetry On-line in Reactor) dedicated to the development of a new measurement methodology to quantify both nuclear heating and accurate radiation flux levels (neutrons and photons). The methodology, which is based on experiments carried out under irradiation conditions with a multi-sensor device (ionization chamber, fission chamber, gamma thermometer, calorimeter, SPND, SPGD) as well as works performed out-of nuclear/radiative environment on a reference sensor used to measure nuclear heating (calorimeter), is presented (authors)

  1. On-line measurement of ski-jumper trajectory: combining stereo vision and shape description

    Science.gov (United States)

    Nunner, T.; Sidla, O.; Paar, G.; Nauschnegg, B.

    2010-01-01

    Ski jumping has continuously raised major public interest since the early 70s of the last century, mainly in Europe and Japan. The sport undergoes high-level analysis and development, among others, based on biodynamic measurements during the take-off and flight phase of the jumper. We report on a vision-based solution for such measurements that provides a full 3D trajectory of unique points on the jumper's shape. During the jump synchronized stereo images are taken by a calibrated camera system in video rate. Using methods stemming from video surveillance, the jumper is detected and localized in the individual stereo images, and learning-based deformable shape analysis identifies the jumper's silhouette. The 3D reconstruction of the trajectory takes place on standard stereo forward intersection of distinct shape points, such as helmet top or heel. In the reported study, the measurements are being verified by an independent GPS measurement mounted on top of the Jumper's helmet, synchronized to the timing of camera exposures. Preliminary estimations report an accuracy of +/-20 cm in 30 Hz imaging frequency within 40m trajectory. The system is ready for fully-automatic on-line application on ski-jumping sites that allow stereo camera views with an approximate base-distance ratio of 1:3 within the entire area of investigation.

  2. At-line cotton color measurements by portable color spectrophotometers

    Science.gov (United States)

    As a result of reports of cotton bales that had significant color changes from their initial Uster® High Volume Instrument (HVI™) color measurements, a program was implemented to measure cotton fiber color (Rd, +b) at-line in remote locations (warehouse, mill, etc.). The measurement of cotton fiber...

  3. Advanced power cycling test for power module with on-line on-state VCE measurement

    DEFF Research Database (Denmark)

    Choi, Ui-min; Trintis, Ionut; Blaabjerg, Frede

    2015-01-01

    module. The proposed concept can perform various stress conditions which is valid in a real mission profile and it is using a real power converter application with small loss. The concept of the proposed test setup is first presented. Then, the on-line on-state collector-emitter voltage VCE measurement......Recent research has made an effort to improve the reliability of power electronic systems to comply with more stringent constraints on cost, safety, predicted lifetime and availability in many applications. For this, studies about failure mechanisms of power electronic components and lifetime...... estimation of power semiconductor devices and capacitors have been done. Accelerated power cycling test is one of the common tests to assess the power device module and develop the lifetime model considering the physics of failure. In this paper, a new advanced power cycling test setup is proposed for power...

  4. AISI/DOE Advanced Process Control Program Vol. 4 of 6: ON-LINE, NON-DESTRUCTIVE MECHANICAL PROPERTY MEASUREMENT USING LASER-ULTRASOUND

    Energy Technology Data Exchange (ETDEWEB)

    Andre' Moreau; Martin Lord; Daniel Levesqure; Marc Dubois; Jean Bussiere; Jean-Pierre Monchalin; Christian Padioleau; Guy Lamouche; Teodor Veres; Martin Viens; Harold Hebert; Pierre Basseras; Cheng-Kuei Jen

    2001-03-31

    The goal of this project was to demonstrate the feasibility to measure the mechanical properties, such as yield strength, tensile strength, elongation, strain hardening exponent and plastic strain ratio parameters, of low carbon steel sheets on the production line using laser ultrasound. The ultrasound generated by the developed apparatus travels mostly back and forth in the thickness of the steel sheet. By measuring the time delay between two echoes, and the relative amplitude of these two echoes, one can measure ultrasound velocity and attenuation. These are governed by the microstructure: grain size, crystallographic texture, dislocations, etc. Thus, by recording the time behavior of the ultrasonic signal, one can extract microstructural information. These microstructural information together with the modified Hall-Petch equation allow measurement of the mechanical properties. Through laboratory investigations with a laboratory laser ultrasound system, followed by the installation of a prototype system at LTV Steel Company's No.1 Inspection Line in Cleveland, all target mechanical properties of ultra low carbon (ULC), low carbon (LC) and high strength low alloy (HSLA) steel sample lots were measured meeting or nearly meeting all the target accuracies. Thus, the project realized its goal to demonstrate that the mechanical properties of low carbon steel sheets can be measured on-line using laser ultrasound

  5. Smile line assessment comparing quantitative measurement and visual estimation

    NARCIS (Netherlands)

    Geld, P. Van der; Oosterveld, P.; Schols, J.; Kuijpers-Jagtman, A.M.

    2011-01-01

    INTRODUCTION: Esthetic analysis of dynamic functions such as spontaneous smiling is feasible by using digital videography and computer measurement for lip line height and tooth display. Because quantitative measurements are time-consuming, digital videography and semiquantitative (visual) estimation

  6. On-line measurement of oil contaminants in water by filter-based infrared analyzers

    International Nuclear Information System (INIS)

    Niemelae, P.

    1994-01-01

    The properties of a dedicated infrared analyzer for on-line measurement of the oil content of water, the Oili analyzer, are evaluated theoretically and with laboratory measurements. The analyzer was originally developed for controlling the discharge of ballast and bilge water from oil tankers and more than 200 such instruments have now been supplied for that purpose, representing about 10 % of the total market. Some technical improvements are suggested, and the improved instrument is shown to be capable of measuring oil in water to an accuracy of +- 20 % down to a detection limit of +5-10 ppm in the presence of high concentrations of interfering components and under varying environmental conditions. This opens up new potential applications for the instrument, e.g. the monitoring of water discharges from oil and gas production platforms. The infrared analyzer responds only to the dispersed oil fraction, and if the dissolved fraction is of interest as well, the instrument must be equipped with a UV option, as suggested here

  7. The influence of specific mechanical energy on cornmeal viscosity measured by an on-line system during twin-screw extrusion

    OpenAIRE

    CHANG, Y. K.; MARTINEZ-BUSTOS, F.; PARK, T. S.; KOKINI, J .L.

    1999-01-01

    The influence of specific mechanical energy (SME) on cornmeal viscosity during the twin-screw extrusion at feed moisture contents of 25 and 30% and screw speeds in the range from 100 to 500 rpm was measured. Cornmeal was extruded in a co-rotating, intermeshing twin-screw coupled to a slit die rheometer. One approach to the on-line rheological measurement is to use a slit die with the extruder. In the present work it was show that shear viscosity decreased as a function of SME. The viscosity o...

  8. Evaluation of the monitor cursor-line method for measuring pulmonary artery and central venous pressures.

    Science.gov (United States)

    Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary

    2010-11-01

    To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.

  9. Robust on-line monitoring of biogas processes; Robusta maettekniker on-line foer optimerad biogasproduktion

    Energy Technology Data Exchange (ETDEWEB)

    Nordberg, Aake; Hansson, Mikael; Kanerot, Mija; Krozer, Anatol; Loefving, Bjoern; Sahlin, Eskil

    2010-03-15

    Although demand for biomethane in Sweden is higher than ever, many Swedish codigestion plants are presently operated below their designed capacity. Efforts must be taken to increase the loading rate and guarantee stable operation and high availability of the plants. There are currently no commercial systems for on-line monitoring, and due to the characteristics of the material, including corrosion and tearing, robust applications have to be developed. The objective of this project was to identify and study different monitoring technologies with potential for on-line monitoring of both substrate mixtures and anaerobic digester content. Based on the prerequisites and demands at Boraas Energi och Miljoe AB's (BEMAB, the municipal energy and waste utility in the city of Boraas, Sweden) biogas plant, the extent of the problems, measurement variables and possible ways of managing these issues have been identified and prioritized. The substrate mixtures in question have a high viscosity and are inhomogeneous with variation in composition, which calls for further homogenization, dilution and filtration to achieve high precision in the necessary analyses. Studies of using different mixers and mills showed that the particle size (800 mum) needed for on-line COD measurement could not be achieved. The problem of homogenization can be avoided if indirect measurement methods are used. Laboratory tests with NIR (near-infra red spectroscopy) showed that VS can be predicted (R2=0,78) in the interval of 2-9% VS. Furthermore, impedance can give a measurement of soluble components. However, impedance is not sensitive enough to give a good measurement of total TS. Microwave technology was installed at the production plant and showed a faster response to changes in TS than the existing TS-sensor. However, due to technical problems, the evaluation only could be done during a limited period of ten days. BEMAB will continue the measurements and evaluation of the instrument. The

  10. Anelastic sensitivity kernels with parsimonious storage for adjoint tomography and full waveform inversion

    KAUST Repository

    Komatitsch, Dimitri; Xie, Zhinan; Bozdağ, Ebru; de Andrade, Elliott Sales; Peter, Daniel; Liu, Qinya; Tromp, Jeroen

    2016-01-01

    We introduce a technique to compute exact anelastic sensitivity kernels in the time domain using parsimonious disk storage. The method is based on a reordering of the time loop of time-domain forward/adjoint wave propagation solvers combined with the use of a memory buffer. It avoids instabilities that occur when time-reversing dissipative wave propagation simulations. The total number of required time steps is unchanged compared to usual acoustic or elastic approaches. The cost is reduced by a factor of 4/3 compared to the case in which anelasticity is partially accounted for by accommodating the effects of physical dispersion. We validate our technique by performing a test in which we compare the Kα sensitivity kernel to the exact kernel obtained by saving the entire forward calculation. This benchmark confirms that our approach is also exact. We illustrate the importance of including full attenuation in the calculation of sensitivity kernels by showing significant differences with physical-dispersion-only kernels.

  11. Anelastic sensitivity kernels with parsimonious storage for adjoint tomography and full waveform inversion

    KAUST Repository

    Komatitsch, Dimitri

    2016-06-13

    We introduce a technique to compute exact anelastic sensitivity kernels in the time domain using parsimonious disk storage. The method is based on a reordering of the time loop of time-domain forward/adjoint wave propagation solvers combined with the use of a memory buffer. It avoids instabilities that occur when time-reversing dissipative wave propagation simulations. The total number of required time steps is unchanged compared to usual acoustic or elastic approaches. The cost is reduced by a factor of 4/3 compared to the case in which anelasticity is partially accounted for by accommodating the effects of physical dispersion. We validate our technique by performing a test in which we compare the Kα sensitivity kernel to the exact kernel obtained by saving the entire forward calculation. This benchmark confirms that our approach is also exact. We illustrate the importance of including full attenuation in the calculation of sensitivity kernels by showing significant differences with physical-dispersion-only kernels.

  12. Anelastic sensitivity kernels with parsimonious storage for adjoint tomography and full waveform inversion

    Science.gov (United States)

    Komatitsch, Dimitri; Xie, Zhinan; Bozdaǧ, Ebru; Sales de Andrade, Elliott; Peter, Daniel; Liu, Qinya; Tromp, Jeroen

    2016-09-01

    We introduce a technique to compute exact anelastic sensitivity kernels in the time domain using parsimonious disk storage. The method is based on a reordering of the time loop of time-domain forward/adjoint wave propagation solvers combined with the use of a memory buffer. It avoids instabilities that occur when time-reversing dissipative wave propagation simulations. The total number of required time steps is unchanged compared to usual acoustic or elastic approaches. The cost is reduced by a factor of 4/3 compared to the case in which anelasticity is partially accounted for by accommodating the effects of physical dispersion. We validate our technique by performing a test in which we compare the Kα sensitivity kernel to the exact kernel obtained by saving the entire forward calculation. This benchmark confirms that our approach is also exact. We illustrate the importance of including full attenuation in the calculation of sensitivity kernels by showing significant differences with physical-dispersion-only kernels.

  13. A Measurement and Power Line Communication System Design for Renewable Smart Grids

    Science.gov (United States)

    Kabalci, E.; Kabalci, Y.

    2013-10-01

    The data communication over the electric power lines can be managed easily and economically since the grid connections are already spread around all over the world. This paper investigates the applicability of Power Line Communication (PLC) in an energy generation system that is based on photovoltaic (PV) panels with the modeling study in Matlab/Simulink. The Simulink model covers the designed PV panels, boost converter with Perturb and Observe (P&O) control algorithm, full bridge inverter, and the binary phase shift keying (BPSK) modem that is utilized to transfer the measured data over the power lines. This study proposes a novel method to use the electrical power lines not only for carrying the line voltage but also to transmit the measurements of the renewable energy generation plants. Hence, it is aimed at minimizing the additional monitoring costs such as SCADA, Ethernet-based or GSM based systems by using the proposed technique. Although this study is performed with solar power plants, the proposed model can be applied to other renewable generation systems. Consequently, the usage of the proposed technique instead of SCADA or Ethernet-based systems eliminates additional monitoring costs.

  14. Theodolite Polar measurements system and definition of the grid-lines method

    Directory of Open Access Journals (Sweden)

    Andréa de Seixas

    2004-12-01

    Full Text Available The requirements of construction quality, mainly in the car and airplane industries, accelerate the development of new 3D-Measurement Systems and Measurement Processes that make possible the automatic object recording and it’s post-processing on the basis, for example, on deformations. The geometrical reconstruction of objects or surface requires a minimal number of points, which abstracts and will be fulfill through interpolation its exact form and quality of the object in each case. The applications of the laser for the active signalization of a point object in combination with the directional measurement make possible in such way the determination of objects or surfaces, including also, places where the use of artificial targets is dangerous or impossible. This work describes the development of such measurement system based on two measurement robots or a reflector-free measuring tachymeter. The system is capable of reaching the intersections points of a grid-line that is defined in an appropriate coordinate system. The aim of this paper is to present the development of measurement methods that can reconstruct unknown three-dimensional and not signalized objects. The existing deformation-measurement, based on Pointer Theodolite and a Video Theodolite Measurement System and the other reflector-free Tachymeter Measurement System in context with the problematic analysis of deformation will be presented. The grid-lines Methods appear a solution and stand as new alternative for the geometrical reconstruction of the object surfaces. Its definition and preparations in a suitable coordinate system are discussed in detail.

  15. On-line corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2004-01-01

    ), Electrochemical Noise (EN) and Zero Resistance Ammetry (ZRA). Electrochemical Resistance (ER) has also been used to measure corrosion. The method traditionally only measures corrosion off-line but with newly developed high-sensitive ER technique developed by MetriCorr in Denmark, on-line monitoring is possible...... complicates the chemistry of the environment. Hydrogen sulphide is present in geothermal systems and can be formed as a by-product of sulphate-reducing-bacteria (SRB). The application of electrochemical methods makes on-line monitoring possible. These methods include: Linear Polarization Resistance (LPR....... In order to assess both general corrosion and localized corrosion, it is necessary to apply more than one monitoring technique simultaneously, ZRA or EN for measuring localized corrosion and LPR or ER for measuring general corrosion rate. The advantage of monitoring localized corrosion is indisputable...

  16. On-line fission products measurements during a PWR severe accident: the French DECA-PF project

    Energy Technology Data Exchange (ETDEWEB)

    Ducros, G.; Allinei, P.G.; Roure, C. [CEA, DEN, F-13108 Saint-Paul-lez-Durance, (France); Rozel, C. [EDF SEPTEN, 12-14 Avenue Dutrievoz, F-69628, Villeurbanne, (France); Blanc De Lanaute, N. [CANBERRA, 1 rue des Herons, F-78182, Saint Quentin en Yvelines, (France); Musoyan, G. [AREVA, Tour AREVA, 1 place Jean Millier, F-92084 Paris La Defense Cedex, (France)

    2015-07-01

    Following the Fukushima accident, a lot of recommendations was drawn by international organizations (IAEA, OECD, NUGENIA network...) in order to improve the safety in such accidental conditions and mitigate their consequences. One of these recommendations was to improve the robustness of the instrumentation, which was dramatically lacking at Fukushima, as well as to better determine the Source Term involved in nuclear accident. The DECA-PF project (Diagnosis of a degraded reactor core through Fission Product measurements) was elaborated in this context and selected as one of 21 collaborative R and D projects in the field of nuclear safety and radioprotection, funded in May 2013 by the French National Research Agency. Over the months following the Fukushima accident, a CEA crisis team was held in order to analyze on-line the situation taking into account the data delivered by TEPCO and other organizations. Despite the difficulties encountered concerning the reliability of these data, the work performed showed the high capacity of Fission Products (FP) measurements to get a diagnosis relative to the status of the reactors and the spent fuel pools (SFP). Based on these FP measurements, it was possible to conclude that the main origin of the releases was coming from the cores and not from the SFP, in particular for SFP-4 which was of high concern, and that the degradation level of the reactors was very large, including probably an extensive core melting. To improve the reliability of this kind of diagnosis, the necessity to get such measurements as soon as possible after the accident and as near as possible from the reactor was stressed. In this way the present DECA-PF project intends to develop a new and innovative instrumentation taking into account the design of the French nuclear power plants on which sand bed filters have been implemented for severe accident management. Three complementary techniques, devoted to measure the FP release on-line, are being studied

  17. Considerations in applying on-line IC techniques to BWR's

    International Nuclear Information System (INIS)

    Kaleda, R.J.

    1992-01-01

    Ion-Chromatography (IC) has moved from its traditional role as a laboratory analytical tool to a real time, dynamic, on-line measurement device to follow ppb and sub-ppb concentrations of deleterious impurities in nuclear power plants. Electric Power Research Institute (EPRI), individual utilities, and industry all have played significant roles in effecting the transition. This paper highlights considerations and the evolution in current on-line Ion Chromatography systems. The first applications of on-line techniques were demonstrated by General Electric (GE) under EPRI sponsorship at Rancho Seco (1980), Calvert Cliffs, and McGuire nuclear units. The primary use was for diagnostic purposes. Today the on-line IC applications have been expanded to include process control and routine plant monitoring. Current on-line IC's are innovative in design, promote operational simplicity, are modular for simplified maintenance and repair, and use field-proven components which enhance reliability. Conductivity detection with electronic or chemical suppression and spectrometric detection techniques are intermixed in applications. Remote multi-point sample systems have addressed memory effects. Early applications measured ionic species in the part per billion range. Today reliable part per trillion measurements are common for on-line systems. Current systems are meeting the challenge of EPRI guideline requirements. Today's on-line IC's, with programmed sampling systems, monitor fluid streams throughout a power plant, supplying data that can be trended, stored and retrieved easily. The on-line IC has come of age. Many technical challenges were overcome to achieve today's IC

  18. A programming system for bubble chamber photographs measuring tables on-line to a computer

    International Nuclear Information System (INIS)

    Miche, Roger.

    1975-06-01

    A programming system available on an industrial computer, type PDP 15/20, performing the exploitation of bubble chamber pictures with the projection tables on line to the computer was developed. This system must suit the particular conditions met in the analysis of photographs from different bubble chambers, the different stage for dealing with the views (scanning, premeasurement, measurement) adapting to different strategies in the handling of measurements. The exploitation of photographs takes place in a conversational mode to which a concrete form is given by sending messages to the operators at the tables and by receiving coded answers. In this framework, the aims of the operating system are: to guide the operator work at the tables while allowing them to interrupt the normal sequence of events, to carry out some elementary logical checks, to write on magnetic tape the checked data with the appropriate labels as required [fr

  19. Comparison of Echo 7 field line length measurements to magnetospheric model predictions

    International Nuclear Information System (INIS)

    Nemzek, R.J.; Winckler, J.R.; Malcolm, P.R.

    1992-01-01

    The Echo 7 sounding rocket experiment injected electron beams on central tail field lines near L = 6.5. Numerous injections returned to the payload as conjugate echoes after mirroring in the southern hemisphere. The authors compare field line lengths calculated from measured conjugate echo bounce times and energies to predictions made by integrating electron trajectories through various magnetospheric models: the Olson-Pfitzer Quiet and Dynamic models and the Tsyganenko-Usmanov model. Although Kp at launch was 3-, quiet time magnetic models est fit the echo measurements. Geosynchronous satellite magnetometer measurements near the Echo 7 field lies during the flight were best modeled by the Olson-Pfitzer Dynamic Model and the Tsyganenko-Usmanov model for Kp = 3. The discrepancy between the models that best fit the Echo 7 data and those that fit the satellite data was most likely due to uncertainties in the small-scale configuration of the magnetospheric models. The field line length measured by the conjugate echoes showed some temporal variation in the magnetic field, also indicated by the satellite magnetometers. This demonstrates the utility an Echo-style experiment could have in substorm studies

  20. Design and Validation with Measurements of the LEIR Injection Line

    CERN Document Server

    Roncarolo, F; Chanel, M; Dumas, L; Scrivens, R

    2006-01-01

    The CERN Low Energy Ion Ring (LEIR) commissioning started in the year 2005. O4+and Pb54+ion beams are transferred at 4.2 MeV/nucleon from Linac 3 to LEIR through a low energy transfer line, for which the constraints and the resulting optics design are presented. First trajectory and dispersion measurements agreed only poorly with the theoretical model. Iterations of a refined optics model and further measurements improved the agreement between experimental observations and expectations. In particular, the effect of quadrupole errors in the line dipole magnets is discussed.

  1. Thermographic Sensing For On-Line Industrial Control

    Science.gov (United States)

    Holmsten, Dag

    1986-10-01

    It is today's emergence of thermoelectrically cooled, highly accurate infrared linescanners and imaging systems that has definitely made on-line Infraread Thermography (IRT) possible. Specifically designed for continuous use, these scanners are equipped with dedicated software capable of monitoring and controlling highly complex thermodynamic situations. This paper will outline some possible implications of using IRT on-line by describing some uses of this technology in the steel-making (hot rolling) and automotive industries (machine-vision). A warning is also expressed that IRT technology not originally designed for automated applications e.g. high resolution, imaging systems, should not be directly applied to an on-line measurement situation without having its measurement resolution, accuracy and especially its repeatability, reliably proven. Some suitable testing procedures are briefly outlined at the end of the paper.

  2. A mixed integer linear programming model to reconstruct phylogenies from single nucleotide polymorphism haplotypes under the maximum parsimony criterion

    Science.gov (United States)

    2013-01-01

    Background Phylogeny estimation from aligned haplotype sequences has attracted more and more attention in the recent years due to its importance in analysis of many fine-scale genetic data. Its application fields range from medical research, to drug discovery, to epidemiology, to population dynamics. The literature on molecular phylogenetics proposes a number of criteria for selecting a phylogeny from among plausible alternatives. Usually, such criteria can be expressed by means of objective functions, and the phylogenies that optimize them are referred to as optimal. One of the most important estimation criteria is the parsimony which states that the optimal phylogeny T∗for a set H of n haplotype sequences over a common set of variable loci is the one that satisfies the following requirements: (i) it has the shortest length and (ii) it is such that, for each pair of distinct haplotypes hi,hj∈H, the sum of the edge weights belonging to the path from hi to hj in T∗ is not smaller than the observed number of changes between hi and hj. Finding the most parsimonious phylogeny for H involves solving an optimization problem, called the Most Parsimonious Phylogeny Estimation Problem (MPPEP), which is NP-hard in many of its versions. Results In this article we investigate a recent version of the MPPEP that arises when input data consist of single nucleotide polymorphism haplotypes extracted from a population of individuals on a common genomic region. Specifically, we explore the prospects for improving on the implicit enumeration strategy of implicit enumeration strategy used in previous work using a novel problem formulation and a series of strengthening valid inequalities and preliminary symmetry breaking constraints to more precisely bound the solution space and accelerate implicit enumeration of possible optimal phylogenies. We present the basic formulation and then introduce a series of provable valid constraints to reduce the solution space. We then prove

  3. The Corrosion Inhibition Characteristics of Sodium Nitrite Using an On-line Corrosion Rate Measurement System

    International Nuclear Information System (INIS)

    Park, Mal-Yong; Kang, Dae-Jin; Moon, Jeon-Soo

    2015-01-01

    An on-line corrosion rate measurement system was developed using a personal computer, a data acquisition board and program, and a 2-electrode corrosion probe. Reliability of the developed system was confirmed with through comparison test. With this system, the effect of sodium nitrite (NaNO 2 ) as a corrosion inhibitor were studied on iron and aluminum brass that were immersed in sodium chloride (NaCl) solution. Corrosion rate was measured based on the linear polarization resistance method. The corrosion rates of aluminum brass and iron in 1% NaCl solutions were measured to be 0.290 mm per year (mmpy) and 0.2134 mmpy, respectively. With the addition of 200 ppm of NO 2 - , the corrosion rates decreased to 0.0470 mmpy and 0.0254 mmpy. The addition of NO 2 - caused a decrease in corrosion rates of both aluminum brass and iron, yet the NO 2 - acted as a more effective corrosion inhibitor for iron. than aluminum brass

  4. The Amalgamation of SVR and ANFIS Models with Synchronized Phasor Measurements for On-Line Voltage Stability Assessment

    Directory of Open Access Journals (Sweden)

    Mohammed Amroune

    2017-10-01

    Full Text Available This paper presents the application of support vector regression (SVR and adaptive neuro-fuzzy inference system (ANFIS models that are amalgamated with synchronized phasor measurements for on-line voltage stability assessment. As the performance of SVR model extremely depends on the good selection of its parameters, the recently developed ant lion optimizer (ALO is adapted to seek for the SVR’s optimal parameters. In particular, the input vector of ALO-SVR and ANFIS soft computing models is provided in the form of voltage magnitudes provided by the phasor measurement units (PMUs. In order to investigate the effectiveness of ALO-SVR and ANFIS models towards performing the on-line voltage stability assessment, in-depth analyses on the results have been carried out on the IEEE 30-bus and IEEE 118-bus test systems considering different topologies and operating conditions. Two statistical performance criteria of root mean square error (RMSE and correlation coefficient (R were considered as metrics to further assess both of the modeling performances in contrast with the power flow equations. The results have demonstrated that the ALO-SVR model is able to predict the voltage stability margin with greater accuracy compared to the ANFIS model.

  5. Modified thermogravimetric apparatus to measure magnetic susceptibility on-line during annealing of metastable ferromagnetic materials

    International Nuclear Information System (INIS)

    Luciani, G.; Constantini, A.; Branda, F.; Ausanio, G.; Hison, C.; Iannotti, V.; Luponio, C.; Lanotte, L.

    2004-01-01

    The insertion of proper coils to generate a magnetic field, with controlled gradient, in a standard thermogravimetric apparatus is shown to be a valid solution to measure on-line, upon heat treatment, the magnetic susceptibility in ribbon shaped samples of a metastable ferromagnetic material. The method is very useful to individuate the annealing conditions that optimise soft or hard magnetic properties without using separate apparatuses for heat treatment, control of the structural phase transition and characterization of magnetic susceptibility

  6. In-line measurement of transparent micro membranes

    DEFF Research Database (Denmark)

    Fugl, Jimmy; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2007-01-01

    The purpose of this work has been to develop a new measuring principle to bring down the time for quality assurance, and obtain larger uniformity of the end product, in a specific production line. The production concerns thin transparent micro membranes (approx 35 micron thickness) dispensed...... in micro cavities, each membrane consisting of several membrane layers. A quality control should be performed every time a new layer is dispensed. The paper describes a new way of measuring membrane thickness. The method was achieved through the use of a vision system, whereby the thickness of the thin...... transparent micro membrane is determined in terms of the light absorbance of the membrane substrate. The new and faster measuring method makes is possible to measure the thickness of individual membranes and perform a 100% quality control....

  7. Relationship of the functional movement screen in-line lunge to power, speed, and balance measures.

    Science.gov (United States)

    Hartigan, Erin H; Lawrence, Michael; Bisson, Brian M; Torgerson, Erik; Knight, Ryan C

    2014-05-01

    The in-line lunge of the Functional Movement Screen (FMS) evaluates lateral stability, balance, and movement asymmetries. Athletes who score poorly on the in-line lunge should avoid activities requiring power or speed until scores are improved, yet relationships between the in-line lunge scores and other measures of balance, power, and speed are unknown. (1) Lunge scores will correlate with center of pressure (COP), maximum jump height (MJH), and 36.6-meter sprint time and (2) there will be no differences between limbs on lunge scores, MJH, or COP. Descriptive laboratory study. Level 3. Thirty-seven healthy, active participants completed the first 3 tasks of the FMS (eg, deep squat, hurdle step, in-line lunge), unilateral drop jumps, and 36.6-meter sprints. A 3-dimensional motion analysis system captured MJH. Force platforms measured COP excursion. A laser timing system measured 36.6-m sprint time. Statistical analyses were used to determine whether a relationship existed between lunge scores and COP, MJH, and 36.6-m speed (Spearman rho tests) and whether differences existed between limbs in lunge scores (Wilcoxon signed-rank test), MJH, and COP (paired t tests). Lunge scores were not significantly correlated with COP, MJH, or 36.6-m sprint time. Lunge scores, COP excursion, and MJH were not statistically different between limbs. Performance on the FMS in-line lunge was not related to balance, power, or speed. Healthy participants were symmetrical in lunging measures and MJH. Scores on the FMS in-line lunge should not be attributed to power, speed, or balance performance without further examination. However, assessing limb symmetry appears to be clinically relevant.

  8. Conductance measurement by two-line probe method of polypyrrole nano-films formed on mica by admicellar polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Mou, C.-Y. [Graduate Institute of Textile Engineering, Feng Chia University, Taichung 40724, Taiwan (China); Yuan, W.-L. [Department of Chemical Engineering, Feng Chia University, Taichung 40724, Taiwan (China)], E-mail: wyuan@fcu.edu.tw; Tsai, I-S. [Graduate Institute of Textile Engineering, Feng Chia University, Taichung 40724, Taiwan (China); O' Rear, Edgar A. [School of Chemical, Biological and Material Engineering, University of Oklahoma, Norman, OK 73019 (United States); Barraza, Harry [Unilever R and D HPC, Quarry Road East, Bebington, Wirral, CH63 3JW (United Kingdom)

    2008-10-01

    Measuring the electrical conductance is of importance in fabricating electronic devices based on semiconducting thin films. In this report, electrically conducting polypyrrole (PPy) nano-films were deposited on insulating mica plates by admicellar polymerization. It becomes difficult to measure such film conductance in the lateral direction due the nanometric thickness which only allows for very low electrical current. In order to understand the effects of surfactant on the film conductivity, morphological studies using atomic force microscopy and conductance measurements with a sub-fA multimeter were performed. Higher conductances were found for PPy thin films made using surfactant templates, than that of a bare mica surface. Using the two-line probe method by drawing two lines of silver glue 8 mm apart on the sample surface, the current-voltage curves of bare mica surface yielded a lateral conductance of 6.0 x 10{sup -13} S. In comparison, PPy thin films made using sodium dodecyl sulfate (SDS) and cetyl trimethyl ammonium bromide (CTAB) as surfactant templates showed conductances of 1.2 x 10{sup -11} S and 7.7 x 10{sup -12} S, respectively. The higher conductances indicate tunneling, hopping, and percolation of charge carriers throughout the films. The lower-bound conductivities were calculated as 4.0 x 10{sup -3} S/cm and 2.6 x 10{sup -3} S/cm, measured based on the average thickness 2.3 nm for the SDS-PPy films and 2.4 nm for the CTAB-PPy films. Conductivities for both SDS and CTAB template PPy films are found to be of the same order.

  9. Conductance measurement by two-line probe method of polypyrrole nano-films formed on mica by admicellar polymerization

    International Nuclear Information System (INIS)

    Mou, C.-Y.; Yuan, W.-L.; Tsai, I-S.; O'Rear, Edgar A.; Barraza, Harry

    2008-01-01

    Measuring the electrical conductance is of importance in fabricating electronic devices based on semiconducting thin films. In this report, electrically conducting polypyrrole (PPy) nano-films were deposited on insulating mica plates by admicellar polymerization. It becomes difficult to measure such film conductance in the lateral direction due the nanometric thickness which only allows for very low electrical current. In order to understand the effects of surfactant on the film conductivity, morphological studies using atomic force microscopy and conductance measurements with a sub-fA multimeter were performed. Higher conductances were found for PPy thin films made using surfactant templates, than that of a bare mica surface. Using the two-line probe method by drawing two lines of silver glue 8 mm apart on the sample surface, the current-voltage curves of bare mica surface yielded a lateral conductance of 6.0 x 10 -13 S. In comparison, PPy thin films made using sodium dodecyl sulfate (SDS) and cetyl trimethyl ammonium bromide (CTAB) as surfactant templates showed conductances of 1.2 x 10 -11 S and 7.7 x 10 -12 S, respectively. The higher conductances indicate tunneling, hopping, and percolation of charge carriers throughout the films. The lower-bound conductivities were calculated as 4.0 x 10 -3 S/cm and 2.6 x 10 -3 S/cm, measured based on the average thickness 2.3 nm for the SDS-PPy films and 2.4 nm for the CTAB-PPy films. Conductivities for both SDS and CTAB template PPy films are found to be of the same order

  10. Electric field simulation and measurement of a pulse line ion accelerator

    International Nuclear Information System (INIS)

    Shen Xiaokang; Zhang Zimin; Cao Shuchun; Zhao Hongwei; Zhao Quantang; Liu Ming; Jing Yi; Wang Bo; Shen Xiaoli

    2012-01-01

    An oil dielectric helical pulse line to demonstrate the principles of a Pulse Line Ion Accelerator (PLIA) has been designed and fabricated. The simulation of the axial electric field of an accelerator with CST code has been completed and the simulation results show complete agreement with the theoretical calculations. To fully understand the real value of the electric field excited from the helical line in PLIA, an optical electric integrated electric field measurement system was adopted. The measurement result shows that the real magnitude of axial electric field is smaller than that calculated, probably due to the actual pitch of the resister column which is much less than that of helix. (authors)

  11. Measurement of response time and detection of degradation in pressure sensor/sensing-line systems

    International Nuclear Information System (INIS)

    Buchanan, M.E.; Miller, L.F.; Kerlin, T.W.; Ragan, G.; March-Leuba, J.; Thie, J.A.

    1985-01-01

    A team evaluated several methods for remote measurement of the response time and detection of degradation (blockage or air in lines) of pressure sensor/sensing line systems typical of nuclear power plants. A method was developed for obtaining the response time of force-balance pressure transmitters by briefly interrupting the power supply to the transmitter. The data thus generated are then analyzed in conjunction with a model to predict transmitter response to an actual pressure perturbation. The research team also evaluated a pressure perturbation method for determining the asymptotic delay time of a pressure-sensing line and found that this method yields accurate results for essentially unblocked sensing lines. However, these pressure perturbation tests are not recommended for use in nuclear power plants because they are difficult to implement on-line. A third method for remote measurement applied noise analysis method that yielded accurate estimates of asymptotic delay times for blockage or air in sensing lines. Even though noise analysis methods worked well in the laboratory, it is recommended that further evaluation be performed in operating nuclear plants. (orig.)

  12. Measurement of response time and detection of degradation in pressure sensor/sensing line systems

    International Nuclear Information System (INIS)

    Buchanan, M.E.; Miller, L.F.; Thie, J.A.; Kerlin, T.W.; Ragan, G.E.; March-Leuba, J.

    1985-09-01

    A team evaluated several methods for remote measurement of the response time and detection of degradation (blockage or air in lines) of pressure sensor/sensing line systems typical of nuclear power plants. A method was developed for obtaining the response time of force-balance pressure transmitters by briefly interrupting the power supply to the transmitter. The data thus generated are then analyzed in conjunction with a model to predict transmitter response to an actual pressure perturbation. The research team also evaluated a pressure perturbation method for determining the asymptotic delay time of a pressure-sensing line and found that this method yields accurate results for essentially unblocked sensing lines. However, these pressure perturbation tests are not recommended for use in nuclear power plants because they are difficult to implement on-line. A third method for remote measurement applied noise analysis methods that yielded accurate estimates of asymptotic delay times for blockage or air in sensing lines. Even though noise analysis methods worked well in the laboratory, it is recommended that further evaluation be performed in operating nuclear plants

  13. An integer programming formulation of the parsimonious loss of heterozygosity problem.

    Science.gov (United States)

    Catanzaro, Daniele; Labbé, Martine; Halldórsson, Bjarni V

    2013-01-01

    A loss of heterozygosity (LOH) event occurs when, by the laws of Mendelian inheritance, an individual should be heterozygote at a given site but, due to a deletion polymorphism, is not. Deletions play an important role in human disease and their detection could provide fundamental insights for the development of new diagnostics and treatments. In this paper, we investigate the parsimonious loss of heterozygosity problem (PLOHP), i.e., the problem of partitioning suspected polymorphisms from a set of individuals into a minimum number of deletion areas. Specifically, we generalize Halldórsson et al.'s work by providing a more general formulation of the PLOHP and by showing how one can incorporate different recombination rates and prior knowledge about the locations of deletions. Moreover, we show that the PLOHP can be formulated as a specific version of the clique partition problem in a particular class of graphs called undirected catch-point interval graphs and we prove its general $({\\cal NP})$-hardness. Finally, we provide a state-of-the-art integer programming (IP) formulation and strengthening valid inequalities to exactly solve real instances of the PLOHP containing up to 9,000 individuals and 3,000 SNPs. Our results give perspectives on the mathematics of the PLOHP and suggest new directions on the development of future efficient exact solution approaches.

  14. Singular Spectrum Analysis for Astronomical Time Series: Constructing a Parsimonious Hypothesis Test

    Science.gov (United States)

    Greco, G.; Kondrashov, D.; Kobayashi, S.; Ghil, M.; Branchesi, M.; Guidorzi, C.; Stratta, G.; Ciszak, M.; Marino, F.; Ortolan, A.

    We present a data-adaptive spectral method - Monte Carlo Singular Spectrum Analysis (MC-SSA) - and its modification to tackle astrophysical problems. Through numerical simulations we show the ability of the MC-SSA in dealing with 1/f β power-law noise affected by photon counting statistics. Such noise process is simulated by a first-order autoregressive, AR(1) process corrupted by intrinsic Poisson noise. In doing so, we statistically estimate a basic stochastic variation of the source and the corresponding fluctuations due to the quantum nature of light. In addition, MC-SSA test retains its effectiveness even when a significant percentage of the signal falls below a certain level of detection, e.g., caused by the instrument sensitivity. The parsimonious approach presented here may be broadly applied, from the search for extrasolar planets to the extraction of low-intensity coherent phenomena probably hidden in high energy transients.

  15. Line overlap measurements for resonant photo-pumping of x-ray lasers

    International Nuclear Information System (INIS)

    Elliott, S.R.; Beiersdorfer, P.; Nilsen, J.

    1993-01-01

    Measurement taken on the LLNL EBIT to search for the possible photo-pumping of the 3p-3s lasing transitions in Ni-like ions of elements with Z=30--40 and the 4d-4p lasing transitions in Ne-like ions of elements with Z=47-73 are reported. A high-resolution crystral spectrometer was used to measure wavelengths of the Ne-like 2p-4d and the Ni-like 3d-5f and 3d-6f laser level feeding transitions relative to candidate pump lines in various H-, He-, and Ni-like ions. To date, the most promising candidate is Ni-like Pt pumping Ne-like Rb at 2512 eV. The line energies differ by 0.4±0.1 eV or by 160 ppm

  16. Development and application of an on-line tritium production rate measuring method

    International Nuclear Information System (INIS)

    Yamaguchi, Seiya

    1989-06-01

    A highly sensitive on-line method for measuring the tritium production rate (TPR) of 6 Li was developed using the response difference of 6 Li and 7 Li-glass scintillators in a mixed neutron-gamma radiation field. A fitting method for subtracting the pulse height spectrum of 7 Li-glass from that of 6 Li-glass was introduced. The contribution of competing reactions such as 6 Li (n, n 'd) 4 He was estimated by kinematical analyses. An absolute value of the 6 Li content was determined by a chemical analysis. The thermal flux perturbation due to 6 Li-glass of various thickness and 6 Li contents was evaluated by measurement in a thermal neutron field and calculation by the modified Skyrme theory. A Monte Carlo calculation of the self-shielding effect was also made. The dependence of the self-shielding on neutron energy was examined by this Monte Carlo code. The edge effect, i.e., distortion of the pulse height spectrum due to partial energy deposition of the alpha and/or the triton, was investigated by measurement in a thermal neutron field and by a Monte Carlo simulation that was based on the scintillation mechanism and considered Bragg absorption and the ratio of contributions to luminescence by the alpha and the triton. The dependence of the edge effect on neutron energy was examined by this Monte Carlo code. This method was applied to the measurement of TPR distributions in simulated fusion blanket assemblies bombarded by D-T neutrons. Absolute values of the TPR were obtained with an experimental error of 3∼6 %. The measured results were compared with those of conventional β-counting methods and good agreement was obtained. An optical fiber system, using miniature lithium-glass scintillators, was fabricated for purpose of microminiaturization of detector size and adaption to strong electromagnetic field. Applicability of this system to a D-T neutron field was demonstrated. (author)

  17. Organization of the M-6000 computer calculating process in the CAMAC on-line measurement systems for a physical experiment

    International Nuclear Information System (INIS)

    Bespalova, T.V.; Volkov, A.S.; Golutvin, I.A.; Maslov, V.V.; Nevskaya, N.A.; Okonishnikov, A.A.; Terekhov, V.E.; Shilkin, I.P.

    1977-01-01

    Discussed are the basic results of the work on designing the software of the computer measuring complex (CMC) which uses the M-6000 computer and operates on line with an accelerator. All the CMC units comply with the CAMAC standard. The CMC incorporates a mainframe memory, twenty-four kilobytes of 16-digit words in size, and external memory on magnetic disks, 1 megabyte in size. Suggested is a modification of the technique for designing the CMC software providing for program complexes which are dynamically adjusted by an experimentalist for the given experiment for a short time. The CMC software comprises the following major portions: a software generator, data acquisition program, on-line data processing routines, off-line data processing programs and programs for data recording on magnetic tapes and disks. Testing of the designed CMC has revealed that the total data processing time equals to from 150 to 500 ms

  18. Sex differences on a measure of conformity in automated teller machine lines.

    Science.gov (United States)

    Reysen, Stephen; Reysen, Matthew B

    2004-10-01

    Sex differences in conformity were examined as participants approached two ATMs, one of which was occupied by three confederates and the other immediately available. The number of men and women in the line in front of one of the ATMs was manipulated (3 men or 3 women), and an unobtrusive observer recorded the sex of each participant. The results indicated that women were more likely than men to wait in line to use the ATM regardless of the makeup of the line. Thus, the present study provides evidence in favor of the idea that sex differences in conformity are evident on a common task performed in a natural setting.

  19. Measuring a Fiber-Optic Delay Line Using a Mode-Locked Laser

    Science.gov (United States)

    Tu, Meirong; McKee, Michael R.; Pak, Kyung S.; Yu, Nan

    2010-01-01

    losses in the ring. When mode locking is achieved, oscillation occurs in all the modes having the same phase and same polarization. The frequency interval between modes, often denoted the free spectral range (FSR), is given by c/nL, where c is the speed of light in vacuum, n is the effective index of refraction of the fiber, and L is the total length of optical path around the ring. Therefore, the length of the fiber-optic delay line, as part of the length around the ring, can be calculated from the FSRs measured with and without the delay line incorporated into the ring. For this purpose, the FSR measurements are made by use of the optical and radio-frequency spectrum analyzers. In experimentation on a 10-km-long fiber-optic delay line, it was found that this setup made it possible to measure the length to within a fractional error of about 3 10(exp -6), corresponding to a length error of 3 cm. In contrast, measurements by optical time-domain reflectometry and mechanical measurement were found to be much less precise: For optical time-domain reflectometry, the fractional error was found no less than 10(exp -4) (corresponding to a length error of 1 m) and for mechanical measurement, the fractional error was found to be about 10(exp -2) (corresponding to a length error of 100 m).

  20. Dynamic Line Rating - Technologies and Challenges of PMU on Overhead Lines

    DEFF Research Database (Denmark)

    Alvarez, David; Rosero, Javier; Silva, Filipe Miguel Faria da

    2016-01-01

    for line rating computation and monitoring are identified, these are: sensors, communications, management information system and information analysis tools, which are part of integral dynamic line rating systems. Finally, the benefits and challenges of using phasor measurement units for real time capacity...

  1. On image tube spectrophotometry of weak emission lines

    International Nuclear Information System (INIS)

    Duflot, R.

    1979-01-01

    The usual precision of image tube spectrophotometry measures relative to low intensity lines can be improved by the 'method of two lines'. This operating process tested on H II galactic regions leads to a precision of 13%. (Auth.)

  2. Relationship of the Functional Movement Screen In-Line Lunge to Power, Speed, and Balance Measures

    Science.gov (United States)

    Hartigan, Erin H.; Lawrence, Michael; Bisson, Brian M.; Torgerson, Erik; Knight, Ryan C.

    2014-01-01

    Background: The in-line lunge of the Functional Movement Screen (FMS) evaluates lateral stability, balance, and movement asymmetries. Athletes who score poorly on the in-line lunge should avoid activities requiring power or speed until scores are improved, yet relationships between the in-line lunge scores and other measures of balance, power, and speed are unknown. Hypothesis: (1) Lunge scores will correlate with center of pressure (COP), maximum jump height (MJH), and 36.6-meter sprint time and (2) there will be no differences between limbs on lunge scores, MJH, or COP. Study Design: Descriptive laboratory study. Level of Evidence: Level 3. Methods: Thirty-seven healthy, active participants completed the first 3 tasks of the FMS (eg, deep squat, hurdle step, in-line lunge), unilateral drop jumps, and 36.6-meter sprints. A 3-dimensional motion analysis system captured MJH. Force platforms measured COP excursion. A laser timing system measured 36.6-m sprint time. Statistical analyses were used to determine whether a relationship existed between lunge scores and COP, MJH, and 36.6-m speed (Spearman rho tests) and whether differences existed between limbs in lunge scores (Wilcoxon signed-rank test), MJH, and COP (paired t tests). Results: Lunge scores were not significantly correlated with COP, MJH, or 36.6-m sprint time. Lunge scores, COP excursion, and MJH were not statistically different between limbs. Conclusion: Performance on the FMS in-line lunge was not related to balance, power, or speed. Healthy participants were symmetrical in lunging measures and MJH. Clinical Relevance: Scores on the FMS in-line lunge should not be attributed to power, speed, or balance performance without further examination. However, assessing limb symmetry appears to be clinically relevant. PMID:24790688

  3. An on-line adaptive core monitoring system

    International Nuclear Information System (INIS)

    Verspeek, J.A.; Bruggink, J.C.; Karuza, J.

    1997-01-01

    An on-line core monitoring system has been in operation for three years in the Dodewaard Nuclear Power Plant. The core monitor uses the on-line measured reactor data as an input for a power distribution calculation. The measurements are frequently performed. The system is used for monitoring as well as for predicting purposes. The limiting thermal hydraulic parameters are monitored as well as the pellet-clad interaction limits. The data are added to a history file used for cycle burn-up calculations and trending of parameters. The reactor states are presented through a convenient graphical user interface. (authors)

  4. On-line measurement of moisture content of powdered food using microwave free-space transmission technique

    International Nuclear Information System (INIS)

    Kim, Ki Bok; Park, Seong Un; Kim, Ji Yeon; Kim, Jong Heon; Lee, ChanJoo

    2006-01-01

    The moisture content of food is not only the most important quality factor but also one of the essential parameters affecting their physical and chemical properties related to storage, capability of processing and quality control. The moisture measurement technique using microwave is very attractive because that method has merits of rapid and accurate measurement in the wider range of moisture content, simple implementation and inexpensive compared with other methods. In this study, microwave free-space transmission technique was applied to measure the moisture content of powdered food. The on-line measurement system consisting of microwave system with 2.5 GHz, 7.0 GHz and 10.5 GHz, conveying device to move the food samples, inlet and outlet of the food samples, guide plate to control the thickness of the food samples, temperature sensing nit, taco-meter and central processing unit having analog to digital convert and microprocessor was constructed and its performance was evaluated.

  5. The efficiency of different search strategies in estimating parsimony jackknife, bootstrap, and Bremer support

    Directory of Open Access Journals (Sweden)

    Müller Kai F

    2005-10-01

    Full Text Available Abstract Background For parsimony analyses, the most common way to estimate confidence is by resampling plans (nonparametric bootstrap, jackknife, and Bremer support (Decay indices. The recent literature reveals that parameter settings that are quite commonly employed are not those that are recommended by theoretical considerations and by previous empirical studies. The optimal search strategy to be applied during resampling was previously addressed solely via standard search strategies available in PAUP*. The question of a compromise between search extensiveness and improved support accuracy for Bremer support received even less attention. A set of experiments was conducted on different datasets to find an empirical cut-off point at which increased search extensiveness does not significantly change Bremer support and jackknife or bootstrap proportions any more. Results For the number of replicates needed for accurate estimates of support in resampling plans, a diagram is provided that helps to address the question whether apparently different support values really differ significantly. It is shown that the use of random addition cycles and parsimony ratchet iterations during bootstrapping does not translate into higher support, nor does any extension of the search extensiveness beyond the rather moderate effort of TBR (tree bisection and reconnection branch swapping plus saving one tree per replicate. Instead, in case of very large matrices, saving more than one shortest tree per iteration and using a strict consensus tree of these yields decreased support compared to saving only one tree. This can be interpreted as a small risk of overestimating support but should be more than compensated by other factors that counteract an enhanced type I error. With regard to Bremer support, a rule of thumb can be derived stating that not much is gained relative to the surplus computational effort when searches are extended beyond 20 ratchet iterations per

  6. SDSS-IV MaNGA: the impact of diffuse ionized gas on emission-line ratios, interpretation of diagnostic diagrams and gas metallicity measurements

    Science.gov (United States)

    Zhang, Kai; Yan, Renbin; Bundy, Kevin; Bershady, Matthew; Haffner, L. Matthew; Walterbos, René; Maiolino, Roberto; Tremonti, Christy; Thomas, Daniel; Drory, Niv; Jones, Amy; Belfiore, Francesco; Sánchez, Sebastian F.; Diamond-Stanic, Aleksandar M.; Bizyaev, Dmitry; Nitschelm, Christian; Andrews, Brett; Brinkmann, Jon; Brownstein, Joel R.; Cheung, Edmond; Li, Cheng; Law, David R.; Roman Lopes, Alexandre; Oravetz, Daniel; Pan, Kaike; Storchi Bergmann, Thaisa; Simmons, Audrey

    2017-04-01

    Diffuse ionized gas (DIG) is prevalent in star-forming galaxies. Using a sample of 365 nearly face-on star-forming galaxies observed by Mapping Nearby Galaxies at APO, we demonstrate how DIG in star-forming galaxies impacts the measurements of emission-line ratios, hence the interpretation of diagnostic diagrams and gas-phase metallicity measurements. At fixed metallicity, DIG-dominated low ΣHα regions display enhanced [S II]/Hα, [N II]/Hα, [O II]/Hβ and [O I]/Hα. The gradients in these line ratios are determined by metallicity gradients and ΣHα. In line ratio diagnostic diagrams, contamination by DIG moves H II regions towards composite or low-ionization nuclear emission-line region (LI(N)ER)-like regions. A harder ionizing spectrum is needed to explain DIG line ratios. Leaky H II region models can only shift line ratios slightly relative to H II region models, and thus fail to explain the composite/LI(N)ER line ratios displayed by DIG. Our result favours ionization by evolved stars as a major ionization source for DIG with LI(N)ER-like emission. DIG can significantly bias the measurement of gas metallicity and metallicity gradients derived using strong-line methods. Metallicities derived using N2O2 are optimal because they exhibit the smallest bias and error. Using O3N2, R23, N2 = [N II]/Hα and N2S2Hα to derive metallicities introduces bias in the derived metallicity gradients as large as the gradient itself. The strong-line method of Blanc et al. (IZI hereafter) cannot be applied to DIG to get an accurate metallicity because it currently contains only H II region models that fail to describe the DIG.

  7. Measurement of contact-line dissipation in a nanometer-thin soap film.

    Science.gov (United States)

    Guo, Shuo; Lee, Chun Huen; Sheng, Ping; Tong, Penger

    2015-01-01

    We report a direct measurement of the friction coefficient ξ(c) of two fluctuating contact lines formed on a fiber surface when a long glass fiber intersects the two water-air interfaces of a thin soap film. The glass fiber of diameter d in the range of 0.4-4 μm and length 100-300 μm is glued onto the front end of a rectangular cantilever used for atomic force microscopy. As a sensitive mechanical resonator, the hanging fiber probe can accurately measure a minute change of its viscous damping caused by the soap film. By measuring the broadening of the resonant peak of the hanging fiber probe with varying viscosity η of the soap film and different surface treatments of the glass fiber, we confirm that the contact line dissipation obeys a universal scaling law, ξ(c)=απdη, where the coefficient α=1.1±0.3 is insensitive to the change of liquid-solid contact angle. The experimental result is in good agreement with the numerical result based on the phase field model under the generalized Navier boundary conditions.

  8. Increasing of MERARG experimental performances: on-line fission gas release measurement by mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pontillon, Y.; Capdevila, H.; Clement, S. [CEA, DEN, DEC, SA3C, LAMIR, F-13108 Saint Paul lez Durance, (France); Guigues, E.; Janulyte, A.; Zerega, Y.; Andre, J. [Aix-Marseille Universite, LISA EA 4672, 13397 MARSEILLE cedex 20, (France)

    2015-07-01

    The MERARG device - implemented at the LECASTAR Hot Laboratory, at the CEA Cadarache - allows characterizing nuclear fuels with respect to the behaviour of fission gases during thermal transients representative of normal or off normal operating nuclear power plant conditions. The fuel is heated in order to extract a part or the total gas inventory it contains. Fission Gas Release (FGR) is actually recorded by mean of both on-line gamma spectrometry station and micro gas chromatography. These two devices monitor the quantity and kinetics of fission gas release rate. They only address {sup 85}Kr radioactive isotope and the elemental quantification of Kr, Xe and He (with a relatively low detection limit in the latter case, typically 5-10 ppm). In order to better estimate the basic mechanisms that promote fission gas release from irradiated nuclear fuels, the CEA fuel study department decided to improve its experimental facility by modifying MERARG to extend the studies of gamma emitter fission gases to all gases (including Helium) with a complete isotopic distribution capability. To match these specifications, a Residual Gas Analyser (RGA) has been chosen as mass spectrometer. This paper presents a review of the main aspects of the qualification/calibration phase of the RGA type analyser. In particular, results recorded over three mass ranges 1-10 u, 80-90 u and 120-140 u in the two classical modes of MERARG, i.e. on-line and off-line measurements are discussed. Results obtained from a standard gas bottle show that the quantitative analysis at a few ppm levels can be achieved for all isotopes of Kr and Xe, as well as masses 2 and 4 u. (authors)

  9. Thermal Boundary Layer Effects on Line-of-Sight Tunable Diode Laser Absorption Spectroscopy (TDLAS) Gas Concentration Measurements.

    Science.gov (United States)

    Qu, Zhechao; Werhahn, Olav; Ebert, Volker

    2018-06-01

    The effects of thermal boundary layers on tunable diode laser absorption spectroscopy (TDLAS) measurement results must be quantified when using the line-of-sight (LOS) TDLAS under conditions with spatial temperature gradient. In this paper, a new methodology based on spectral simulation is presented quantifying the LOS TDLAS measurement deviation under conditions with thermal boundary layers. The effects of different temperature gradients and thermal boundary layer thickness on spectral collisional widths and gas concentration measurements are quantified. A CO 2 TDLAS spectrometer, which has two gas cells to generate the spatial temperature gradients, was employed to validate the simulation results. The measured deviations and LOS averaged collisional widths are in very good agreement with the simulated results for conditions with different temperature gradients. We demonstrate quantification of thermal boundary layers' thickness with proposed method by exploitation of the LOS averaged the collisional width of the path-integrated spectrum.

  10. Innovative Bayesian and Parsimony Phylogeny of Dung Beetles (Coleoptera, Scarabaeidae, Scarabaeinae) Enhanced by Ontology-Based Partitioning of Morphological Characters

    Science.gov (United States)

    Tarasov, Sergei; Génier, François

    2015-01-01

    Scarabaeine dung beetles are the dominant dung feeding group of insects and are widely used as model organisms in conservation, ecology and developmental biology. Due to the conflicts among 13 recently published phylogenies dealing with the higher-level relationships of dung beetles, the phylogeny of this lineage remains largely unresolved. In this study, we conduct rigorous phylogenetic analyses of dung beetles, based on an unprecedented taxon sample (110 taxa) and detailed investigation of morphology (205 characters). We provide the description of morphology and thoroughly illustrate the used characters. Along with parsimony, traditionally used in the analysis of morphological data, we also apply the Bayesian method with a novel approach that uses anatomy ontology for matrix partitioning. This approach allows for heterogeneity in evolutionary rates among characters from different anatomical regions. Anatomy ontology generates a number of parameter-partition schemes which we compare using Bayes factor. We also test the effect of inclusion of autapomorphies in the morphological analysis, which hitherto has not been examined. Generally, schemes with more parameters were favored in the Bayesian comparison suggesting that characters located on different body regions evolve at different rates and that partitioning of the data matrix using anatomy ontology is reasonable; however, trees from the parsimony and all the Bayesian analyses were quite consistent. The hypothesized phylogeny reveals many novel clades and provides additional support for some clades recovered in previous analyses. Our results provide a solid basis for a new classification of dung beetles, in which the taxonomic limits of the tribes Dichotomiini, Deltochilini and Coprini are restricted and many new tribes must be described. Based on the consistency of the phylogeny with biogeography, we speculate that dung beetles may have originated in the Mesozoic contrary to the traditional view pointing to a

  11. On-line monitoring and control of animal-cell cultures

    NARCIS (Netherlands)

    Pol, van der J.J.

    1996-01-01


    On-line analysis and control of biotechnological processes is still the stepchild in industry. In general, only parameters as dissolved-oxygen concentration, pH and temperature are controlled on-line. Important parameters as substrate and inhibitor concentrations are only measured

  12. Automated on-line L-edge measurement of SNM concentration for near-real-time accounting

    International Nuclear Information System (INIS)

    Russo, P.A.; Marks, T. Jr.; Stephens, M.M.; Baker, A.L.; Cobb, D.D.

    1982-09-01

    An L-edge densitometer has been modified, tested, and demonstrated for on-line assay of special nuclear material concentration in flowing solution streams. The demonstration was part of a larger demonstration of near-real-time nuclear materials accounting during a continuous, week-long, cold operation of the Barnwell facility. The L-edge data were automatically analyzed and the results were transmitted to the materials accounting computer once every 5.5 min for the duration of the cold run. This report compares the results of the L-edge analyses with the delayed results obtained from destructive analysis of samples withdrawn from the same process line. Comparisons are also made with the results obtained in near real time from an automated process control instrument installed in series with the L-edge densitometer. The performance of the L-edge instrument was reliable throughout the continuous operation. The assay precision was consistent with that predicted by the counting statistics of the measurement. The results of the L-edge assays show good agreement with those of the destructive assays. A gradually varying discrepancy (of a few percent) between the L-edge and the process control results remains unexplained

  13. Purity, adulteration and price of drugs bought on-line versus off-line in the Netherlands.

    Science.gov (United States)

    van der Gouwe, Daan; Brunt, Tibor M; van Laar, Margriet; van der Pol, Peggy

    2017-04-01

    On-line drug markets flourish and consumers have high expectations of on-line quality and drug value. The aim of this study was to (i) describe on-line drug purchases and (ii) compare on-line with off-line purchased drugs regarding purity, adulteration and price. Comparison of laboratory analyses of 32 663 drug consumer samples (stimulants and hallucinogens) purchased between January 2013 and January 2016, 928 of which were bought on-line. The Netherlands. Primary outcome measures were (i) the percentage of samples purchased on-line and (ii) the chemical purity of powders (or dosage per tablet); adulteration; and the price per gram, blotter or tablet of drugs bought on-line compared with drugs bought off-line. The proportion of drug samples purchased on-line increased from 1.4% in 2013 to 4.1% in 2015. The frequency varied widely, from a maximum of 6% for controlled, traditional substances [ecstasy tablets, 3,4-methylenedioxy-methamphetamine (MDMA) powder, amphetamine powder, cocaine powder, 4-bromo-2,5-dimethoxyphenethylamine (2C-B) and lysergic acid diethylamide (LSD)] to more than a third for new psychoactive substances (NPS) [4-fluoroamphetamine (4-FA), 5/6-(2-aminopropyl)benzofuran (5/6-APB) and methoxetamine (MXE)]. There were no large differences in drug purity, yet small but statistically significant differences were found for 4-FA (on-line 59% versus off-line 52% purity for 4-FA on average, P = 0.001), MDMA powders (45 versus 61% purity for MDMA, P = 0.02), 2C-B tablets (21 versus 10 mg 2C-B/tablet dosage, P = 0.49) and ecstasy tablets (131 versus 121 mg MDMA/tablet dosage, P = 0.05). The proportion of adulterated samples purchased on-line and off-line did not differ, except for 4-FA powder, being less adulterated on-line (χ 2  = 8.3; P < 0.02). Drug prices were mainly higher on-line, ranging for various drugs from 10 to 23% higher than that of drugs purchased off-line (six of 10 substances: P < 0.05). Dutch drug users increasingly

  14. The Daresbury On-Line Isotope Separator (DOLIS)

    International Nuclear Information System (INIS)

    Grant, I.S.; Eastham, D.A.; Groves, J.; Tolfree, D.W.L.; Walker, P.M.; Green, V.R.; Rikovska, J.; Stone, N.J.; Hamilton, W.D.

    1987-01-01

    The isotope separator DOLIS, which is on-line to the Daresbury Laboratory's 20-MV tandem accelerator, is used to measure nuclear moments and decay schemes. Separated beams may be collected on a tape and transported to a counting station, implanted directly into a host lattice at on-line temperatures down to less than 10 mK, or allowed to interact with a collinear laser beam. The present status of DOLIS and its ancillary equipment is described

  15. The Daresbury on-line isotope separator (DOLIS)

    International Nuclear Information System (INIS)

    Grant, I.S.; Eastham, D.A.; Groves, J.; Tolfree, D.W.L.; Walker, P.M.; Green, V.R.; Rikovska, J.; Stone, N.J.; Hamilton, W.D.

    1987-01-01

    The isotope separator DOLIS, which is on-line to the Daresbury Laboratory's 20-MV tandem accelerator, is used to measure nuclear moments and decay schemes. Separated beams may be collected on a tape and transported to a counting station, implanted directly into a host lattice at on-line temperatures down to less than 10 mK, or allowed to interact with a collinear laser beam. The present status of DOLIS and its ancillary equipment is described. (orig.)

  16. Plasma core electron density and temperature measurements using CVI line emissions in TCABR Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Nascimento, F. do, E-mail: fellypen@ifi.unicamp.br [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Centro de Componentes Semicondutores; Machida, M. [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Instituto de Fisica Gleb Wataghin; Severo, J.H.F.; Sanada, E.; Ronchi, G. [Universidade de Sao Paulo (USP), SP (Brazil). Instituto de Fisica

    2015-08-15

    In this work, we present results of electron temperature (T{sub e} ) and density (n {sub e} ) measurements obtained in Tokamak Chauffage Alfven Bresilien (TCABR) tokamak using visible spectroscopy from CVI line emissions which occurs mainly near the center of the plasma column. The presented method is based on a well-known relationship between the particle flux (Γ {sub ion}) and the photon flux (ø {sub ion}) emitted by an ion species combined with ionizations per photon atomic data provided by the atomic data and analysis structure (ADAS) database. In the experiment, we measured the photon fluxes of three different CVI spectral line emissions, 4685.2, 5290.5, and 6200.6 Å (one line per shot). Using this method it was possible to find out the temporal evolution of T{sub e} and n{sub e} in the plasma. The results achieved are in good agreement with T{sub e} and n{sub e} measurements made using other diagnostic tools. (author)

  17. Lightning Performance on Overhead Distribution Lines : After Improvement Field Observation

    Directory of Open Access Journals (Sweden)

    Reynaldo Zoro

    2009-11-01

    Full Text Available Two feeders of 20 kV overhead distribution lines which are located in a high lightning density area are chosen to be observed as a field study due to their good lightning performance after improvement of lightning protection system. These two feeders used the new overhead ground wire and new line arrester equipped with lightning counter on the main lines. The significant reduced of lines outages are reported. Study was carried out to observe these improvements by comparing to the other two feeders line which are not improved and not equipped yet with the ground wire and line arrester. These two feeders located in the nearby area. Two cameras were installed to record the trajectory of the lightning strikes on the improved lines. Lightning peak currents are measured using magnetic tape measurement system installed on the grounding lead of lightning arrester. Lightning overvoltage calculations are carried out by using several scenarios based on observation results and historical lightning data derived from lightning detection network. Lightning overvoltages caused by indirect or direct strikes are analyzed to get the lightning performance of the lines. The best scenario was chosen and performance of the lines were improved significantly by installing overhead ground wire and improvement of lightning arrester installation.

  18. From Off-line to On-line Handwriting Recognition

    NARCIS (Netherlands)

    Lallican, P.; Viard-Gaudin, C.; Knerr, S.

    2004-01-01

    On-line handwriting includes more information on time order of the writing signal and on the dynamics of the writing process than off-line handwriting. Therefore, on-line recognition systems achieve higher recognition rates. This can be concluded from results reported in the literature, and has been

  19. Apparatus and method of measuring fluctuations of excavated mud amount in a slurry line

    International Nuclear Information System (INIS)

    Yamazaki, H.; Kubota, R.; Uchida, Y.; Kasuya, T.; Seki, N.

    1976-01-01

    An apparatus and method for measuring fluctuations in amount of soil in slurry or soil-containing fluid line is described. Each system of feeding the slurry typically to tunneling face and draining it therefrom in the slurry line is provided with gamma-ray densimeter and electromagnetic flow-meter to obtain respective amounts of soil only (dry-soil amounts) in the slurry flowing through each of said systems from respective outputs of these meters in each system, so that actually excavated amount through ground layer of a shielded excavator at the tunneling face can be measured by the difference between the respective dry-soil amounts. The excavator will be advanced depending on this measured amount

  20. Electron temperature measurement by a helium line intensity ratio method in helicon plasmas

    International Nuclear Information System (INIS)

    Boivin, R.F.; Kline, J.L.; Scime, E.E.

    2001-01-01

    Electron temperature measurements in helicon plasmas are difficult. The presence of intense rf fields in the plasma complicates the interpretation of Langmuir probe measurements. Furthermore, the non-negligible ion temperature in the plasma considerably shortens the lifetime of conventional Langmuir probes. A spectroscopic technique based on the relative intensities of neutral helium lines is used to measure the electron temperature in the HELIX (Hot hELicon eXperiment) plasma [P. A. Keiter et al., Phys. Plasmas 4, 2741 (1997)]. This nonintrusive diagnostic is based on the fact that electron impact excitation rate coefficients for helium singlet and triplet states differ as a function of the electron temperature. The different aspects related to the validity of this technique to measure the electron temperature in rf generated plasmas are discussed in this paper. At low plasma density (n e ≤10 11 cm -3 ), this diagnostic is believed to be very reliable since the population of the emitting level can be easily estimated with reasonable accuracy by assuming that all excitation originates from the ground state (steady-state corona model). At higher density, secondary processes (excitation transfer, excitation from metastable, cascading) become more important and a more complex collisional radiative model must be used to predict the electron temperature. In this work, different helium transitions are examined and a suitable transition pair is identified. For an electron temperature of 10 eV, the line ratio is measured as a function of plasma density and compared to values predicted by models. The measured line ratio function is in good agreement with theory and the data suggest that the excitation transfer is the dominant secondary process in high-density plasmas

  1. A New Method of On-line Grid Impedance Estimation for PV Inverter

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Asiminoaei, Lucian; Blaabjerg, Frede

    2004-01-01

    for on-line measuring the grid impedance is presented. The presented method requires no extra hardware being accommodated by typical PV inverters, sensors and CPU, to provide a fast and low cost approach of on-line impedance measurement. By injecting a non-characteristic harmonic current and measuring...

  2. An electromagnetic field measurement protocol for monitoring power lines

    International Nuclear Information System (INIS)

    Lubritto, C.; Iavazzo, A.; D'Onofrio, A.; Palmieri, A.; Sabbarese, C.; Terrasi, F.

    2002-01-01

    In the actions aiming to prevent risks related to the exposure to Low Frequencies Non Ionising electromagnetic Radiations (ELF-NIR), always arises the need to perform measurements in order to assess the field level existing in the considered sites. As a matter of fact very often it turns out difficult to predict, on the base of calculations, with sufficient approximation the field levels, due to extended variability of environmental conditions (e.g. coexistence of several sources, ground and building conformation, etc..). The measurement procedures must follow a methodology that could allow to minimise the interferences with the measurement set-up and the systematic and accidental errors. Risks for the operator and damages to the instrument should also be taken into account. One of the goal set for this research program was then the definition of the measurement protocol for electromagnetic field generated by low frequency non ionising radiation sources. In particular sources like power lines will be considered in order to validate the protocol by means of in-field measurements

  3. On-line Field Measurements of Speciated PM1 Emission Factors from Common South Asian Combustion Sources

    Science.gov (United States)

    DeCarlo, P. F.; Goetz, J. D.; Giordano, M.; Stockwell, C.; Maharjan, R.; Adhikari, S.; Bhave, P.; Praveen, P. S.; Panday, A. K.; Jayarathne, T. S.; Stone, E. A.; Yokelson, R. J.

    2017-12-01

    Characterization of aerosol emissions from prevalent but under sampled combustion sources in South Asia was performed as part of the Nepal Ambient Monitoring and Source Testing Experiment (NAMaSTE) in April 2015. Targeted emission sources included cooking stoves with a variety of solid fuels, brick kilns, garbage burning, crop-residue burning, diesel irrigation pumps, and motorcycles. Real-time measurements of submicron non-refractory particulate mass concentration and composition were obtained using an Aerodyne mini Aerosol Mass Spectrometer (mAMS). Speciated PM1 mass emission factors were calculated for all particulate species (e.g. organics, sulfates, nitrates, chlorides, ammonium) and for each source type using the carbon mass balance approach. Size resolved emission factors were also acquired using a novel high duty cycle particle time-of-flight technique (ePTOF). Black carbon and brown carbon absorption emission factors and absorption Angström exponents were measured using filter loading and scattering corrected attenuation at 370 nm and 880 nm with a dual spot aethalometer (Magee Scientific AE-33). The results indicate that open garbage burning is a strong emitter of organic aerosol, black carbon, and internally mixed particle phase hydrogen chloride (HCl). Emissions of HCl were attributed to the presence chlorinated plastics. The primarily coal fired brick kilns were found to be large emitters of sulfate but large differences in the organic and light absorbing component of emissions were observed between the two kiln types investigated (technologically advanced vs. traditional). These results, among others, bring on-line and field-tested aerosol emission measurements to an area of atmoshperic research dominated by off-line or laboratory based measurements.

  4. A new beam emission polarimetry diagnostic for measuring the magnetic field line angle at the plasma edge of ASDEX Upgrade.

    Science.gov (United States)

    Viezzer, E; Dux, R; Dunne, M G

    2016-11-01

    A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line D α . The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.

  5. Relationship of the Functional Movement Screen In-Line Lunge to Power, Speed, and Balance Measures

    OpenAIRE

    Hartigan, Erin H.; Lawrence, Michael; Bisson, Brian M.; Torgerson, Erik; Knight, Ryan C.

    2014-01-01

    Background: The in-line lunge of the Functional Movement Screen (FMS) evaluates lateral stability, balance, and movement asymmetries. Athletes who score poorly on the in-line lunge should avoid activities requiring power or speed until scores are improved, yet relationships between the in-line lunge scores and other measures of balance, power, and speed are unknown. Hypothesis: (1) Lunge scores will correlate with center of pressure (COP), maximum jump height (MJH), and 36.6-meter sprint time...

  6. Current-zero measurements of vacuum circuit breakers interrupting short-line faults

    NARCIS (Netherlands)

    Smeets, R.P.P.; Linden, van der W.A.

    2003-01-01

    Current zero measurements are performed during short-line fault interruption tests of vacuum circuit breakers. This switching cycle is characterized by a very steep transient recovery voltage. High-resolution measurements of near current-zero arc current and voltage were carried out. Various

  7. Hydrogen Atom Collision Processes in Cool Stellar Atmospheres: Effects on Spectral Line Strengths and Measured Chemical Abundances in Old Stars

    International Nuclear Information System (INIS)

    Barklem, Paul S

    2012-01-01

    The precise measurement of the chemical composition of stars is a fundamental problem relevant to many areas of astrophysics. State-of-the-art approaches attempt to unite accurate descriptions of microphysics, non-local thermodynamic equilibrium (non-LTE) line formation and 3D hydrodynamical model atmospheres. In this paper I review progress in understanding inelastic collisions of hydrogen atoms with other species and their influence on spectral line formation and derived abundances in stellar atmospheres. These collisions are a major source of uncertainty in non-LTE modelling of spectral lines and abundance determinations, especially for old, metal-poor stars, which are unique tracers of the early evolution of our galaxy. Full quantum scattering calculations of direct excitation processes X(nl) + H ↔ X(n'l') + H and charge transfer processes X(nl) + H ↔ X + + H − have been done for Li, Na and Mg [1,2,3] based on detailed quantum chemical data, e.g. [4]. Rate coefficients have been calculated and applied to non-LTE modelling of spectral lines in stellar atmospheres [5,6,7,8,9]. In all cases we find that charge transfer processes from the first excited S-state are very important, and the processes affect measured abundances for Li, Na and Mg in some stars by as much as 60%. Effects vary with stellar parameters (e.g. temperature, luminosity, metal content) and so these processes are important not only for accurate absolute abundances, but also for relative abundances among dissimilar stars.

  8. On-line moisture analysis

    International Nuclear Information System (INIS)

    Cutmore, N.G.; Mijak, D.G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk material. Nuclear-based analysers measure the total hydrogen content in the sample and do not differentiate between free and combined moisture. Such analysers may also be sensitive to material presentation and elemental composition. Very low frequency electromagnetic probes, such as capacitance or conductance probes, operate in the frequency region where the DC conductivity dominates much of the response, which is a function not only of moisture content but also of ionic composition and chemistry. These problems are overcome using microwave transmission techniques, which also have the following advantages, as a true bulk moisture analysis is obtained, because a high percentage of the bulk material is analysed; the moisture estimate is mostly insensitive to any biased presentation of moisture, for example due to stratification of bulk material with different moisture content and because no physical contact is made between the sensor and the bulk material. This is

  9. An objective and parsimonious approach for classifying natural flow regimes at a continental scale

    Science.gov (United States)

    Archfield, S. A.; Kennen, J.; Carlisle, D.; Wolock, D.

    2013-12-01

    Hydroecological stream classification--the process of grouping streams by similar hydrologic responses and, thereby, similar aquatic habitat--has been widely accepted and is often one of the first steps towards developing ecological flow targets. Despite its importance, the last national classification of streamgauges was completed about 20 years ago. A new classification of 1,534 streamgauges in the contiguous United States is presented using a novel and parsimonious approach to understand similarity in ecological streamflow response. This new classification approach uses seven fundamental daily streamflow statistics (FDSS) rather than winnowing down an uncorrelated subset from 200 or more ecologically relevant streamflow statistics (ERSS) commonly used in hydroecological classification studies. The results of this investigation demonstrate that the distributions of 33 tested ERSS are consistently different among the classes derived from the seven FDSS. It is further shown that classification based solely on the 33 ERSS generally does a poorer job in grouping similar streamgauges than the classification based on the seven FDSS. This new classification approach has the additional advantages of overcoming some of the subjectivity associated with the selection of the classification variables and provides a set of robust continental-scale classes of US streamgauges.

  10. Measuring 20-100 T B-fields using Zeeman splitting of sodium emission lines on a 500 kA pulsed power machine

    Energy Technology Data Exchange (ETDEWEB)

    Banasek, J. T., E-mail: jtb254@cornell.edu; Engelbrecht, J. T.; Pikuz, S. A.; Shelkovenko, T. A.; Hammer, D. A. [Cornell University, Ithaca, New York 14850 (United States)

    2016-11-15

    We have shown that Zeeman splitting of the sodium (Na) D-lines at 5890 and 5896 Å can be used to measure the magnetic field (B-field) produced in high current pulsed power experiments. We have measured the B-field next to a return current conductor in a hybrid X-pinch experiment near a peak current of about 500 kA. Na is deposited on the conductor and then is desorbed and excited by radiation from the hybrid X-pinch. The D-line emission spectrum implies B-fields of about 20 T with a return current post of 4 mm diameter or up to 120 T with a return current wire of 0.455 mm diameter. These measurements were consistent or lower than the expected B-field, thereby showing that basic Zeeman splitting can be used to measure the B-field in a pulsed-power-driven high-energy-density (HED) plasma experiment. We hope to extend these measurement techniques using suitable ionized species to measurements within HED plasmas.

  11. Process measuring techniques applying in-line and on-line analyzers. Betriebsmesstechnik unter Einsatz von in-line und on-line Analysatoren

    Energy Technology Data Exchange (ETDEWEB)

    Oehme, F; Jola, M

    1982-01-01

    The measurement and control of classical physical parameters such as pressure, temperature etc, is frequently not sufficient now for optimum process control in chemistry and associated fields. Only the use of inline and online analysers makes it possible to maintain the narrow limits of chemical reaction conditions. This ABC pocket book should help the user to select the best from the large number of available methods of measurement. Using 120 alphabetically arranged key words with many cross-references, it has a well-thought-out treatment of basic measurements and descriptions of apparatus, and on the other hand, it contains selected typical examples of applications. Width rather than depth of information is aimed at. The electrochemical methods discussed are potentiometry (pH value, redox potential, direct potentiometry with ion selective electrodes), conductometry (measurement of conductivity) and voltammetry (polarography, ammetry). Photometry, the measurement of density, the refractive index, surface tension and viscosity are described. From the large number of applications, the examples of textile processing, the cellulose and paper industry, the surface treatment of materials and petrochemicals are discussed. Special attention is paid to the treatment of service water, drinking water and boiler feed water. In connection with questions of work and environmental protection, emission control and the treatment of domestic and industrial waste water are described. With 119 figs.

  12. Automated on-line L-edge measurement of SNM concentration for near-real-time accounting

    International Nuclear Information System (INIS)

    Russo, P.A.; Marks, T. Jr.; Stephens, M.M.; Hsue, S.T.; Baker, A.L.; Cobb, D.D.

    1982-01-01

    The L-edge densitometer developed at Los Alamos National Laboratory has been modified, tested, and demonstrated for on-line assay of special nuclear material concentration in flowing solution streams. The demonstration was part of a larger demonstration of near-real-time nuclear materials accounting during a continuous, week-long, cold operation of the Allied General Nuclear Services facility in Barnwell, South Carolina. The L-edge data were automatically analyzed and the results were transmitted to the materials accounting computer once every 5.5 min for the duration of the cold run. This report compares the results of the L-edge analyses with the delayed results obtained from destructive analysis of samples withdrawn from the same process line. Comparisons are also made with the results obtained in near real time from an automated process control instrument installed in series with the L-edge densitometer. The performance of the L-edge instrument was reliable throughout the continous operation. The assay precision was consistent with that predicted by the counting statistics of the measurement. The results of the L-edge assays show good agreement with those of the destructive assays. A gradually varying discrepancy (of a few percent) between the L-edge and the process control results remains unexplained. 9 figures

  13. Security camera resolution measurements: Horizontal TV lines versus modulation transfer function measurements.

    Energy Technology Data Exchange (ETDEWEB)

    Birch, Gabriel Carisle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Griffin, John Clark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    The horizontal television lines (HTVL) metric has been the primary quantity used by division 6000 related to camera resolution for high consequence security systems. This document shows HTVL measurements are fundamen- tally insufficient as a metric to determine camera resolution, and propose a quantitative, standards based methodology by measuring the camera system modulation transfer function (MTF), the most common and accepted metric of res- olution in the optical science community. Because HTVL calculations are easily misinterpreted or poorly defined, we present several scenarios in which HTVL is frequently reported, and discuss their problems. The MTF metric is discussed, and scenarios are presented with calculations showing the application of such a metric.

  14. Non-invasive and non-destructive measurements of confluence in cultured adherent cell lines.

    Science.gov (United States)

    Busschots, Steven; O'Toole, Sharon; O'Leary, John J; Stordal, Britta

    2015-01-01

    Many protocols used for measuring the growth of adherent monolayer cells in vitro are invasive, destructive and do not allow for the continued, undisturbed growth of cells within flasks. Protocols often use indirect methods for measuring proliferation. Microscopy techniques can analyse cell proliferation in a non-invasive or non-destructive manner but often use expensive equipment and software algorithms. In this method images of cells within flasks are captured by photographing under a standard inverted phase contract light microscope using a digital camera with a camera lens adaptor. Images are analysed for confluence using ImageJ freeware resulting in a measure of confluence known as an Area Fraction (AF) output. An example of the AF method in use on OVCAR8 and UPN251 cell lines is included. •Measurements of confluence from growing adherent cell lines in cell culture flasks is obtained in a non-invasive, non-destructive, label-free manner.•The technique is quick, affordable and eliminates sample manipulation.•The technique provides an objective, consistent measure of when cells reach confluence and is highly correlated to manual counting with a haemocytometer. The average correlation co-efficient from a Spearman correlation (n = 3) was 0.99 ± 0.008 for OVCAR8 (p = 0.01) and 0.99 ± 0.01 for UPN251 (p = 0.01) cell lines.

  15. On-line component ratio measurement of oil/gas/water mixtures using an admittance sensor

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, J A

    1984-01-01

    The operator of a production platform is primarily interested in which types of fluids a well is producing and how quickly these different components are being produced. The component ratio and production rate of a well vary during the life of a field. To optimize production, measurement of each well's output is thus desirable. Current designs for subsea production systems lack means of continuously measuring three-component flows. A new method of component ratio measurement is described. The fraction of oil, gas and water flowing between two insulated electrode plates is determined by measuring both the electrical conductance and suseptance across the sensor. A preliminary evaluation of the new measurement system has been performed using a process oil/ water/air mixture. The method is not limited to small pipe diameters. The only possible limitation is that for low velocities in very large pipe diameters an in-line mixer may be required. Advantages of this new system are that real-time measurement of void fraction and water content is possible if a non-intrusive rugged sensor is used, and there are no range limitations, as each component may be measured for any given concentration. 4 references.

  16. On-line mass spectrometry measurement of fission gas release from nuclear fuel submitted to thermal transients

    International Nuclear Information System (INIS)

    Guigues, E.; Janulyte, A.; Zerega, Y.; Pontillon, Y.

    2013-06-01

    The work presented in this paper has been performed in the framework of a joint research program between Aix-Marseille University and CEA Cadarache. The aim is to develop a mass spectrometer (MS) device for the MERARG facility. MERARG is devoted to the study of fission gas release measurement, from nuclear fuels submitted to annealing tests in high activity laboratory such as LECA-STAR, thanks to gamma spectrometry. The mass spectrometer will then extend the measurement capability from the γ-emitters gases to all the gases involved in the release in order to have a better understanding of the fission gas release dynamics from fuel during thermal transients. Furthermore, the mass spectrometer instrument combines the capabilities and performances of both on-line (for release kinetic) and off-line implementations (for delayed accurate analysis of capacities containing total release gas). The paper deals with two main axes: (1) the modelling of gas sampling inlet device and its performance and (2) the first MS qualification/calibration results. The inlet device samples the gas and also adapts the pressure between MERARG sweeping line at 1.2 bar and mass spectrometer chamber at high vacuum. It is a two-stage device comprising a capillary at inlet, an intermediate vacuum chamber, a molecular leak inlet and a two-stage pumping device. Pressure drops, conductance and throughputs are estimated both for mass spectrometer operation and for exhaust gas recovery. Possible gas segregation is also estimated and device modification is proposed to attain a more accurate calibration. First experimental results obtained from a standard gas bottle show that the quantitative analysis at a few ppm level can be achieved for all isotopes of Kr and Xe, as well as masses 2 and 4 u. (authors)

  17. Distribution Line Parameter Estimation Under Consideration of Measurement Tolerances

    DEFF Research Database (Denmark)

    Prostejovsky, Alexander; Gehrke, Oliver; Kosek, Anna Magdalena

    2016-01-01

    conductance that the absolute compensated error is −1.05% and −1.07% for both representations, as opposed to the expected uncompensated error of −79.68%. Identification of a laboratory distribution line using real measurement data grid yields a deviation of 6.75% and 4.00%, respectively, from a calculation...

  18. Laboratory measurements of the x-ray line emission from neon-like Fe XVII

    International Nuclear Information System (INIS)

    Brown, G V; Beiersdorfer, P; Chen, H; Scofield, J; Boyce, K R; Kelley, R L; Kilbourne, C A; Porter, F S; Gu, M F; Kahn, S M; Szymkowiak, A E

    2006-01-01

    The authors have conducted a systematic study of the dominant x-ray line emission from Fe XVII. These studies include relative line intensities in the optically thin limit, intensities in the presence of radiation from satellite lines from lower charge states of iron, and the absolute excitation cross sections of some of the strongest lines. These measurements were conducted at the Lawrence Livermore National Laboratory electron beam ion trap facility using crystal spectrometers and a NASA-Goddard Space Flight Center microcalorimeter array

  19. Process Analytical Technology and On-Line Spectroscopic Measurements of Chemical Meat Quality

    DEFF Research Database (Denmark)

    Sørensen, Klavs Martin

    This thesis deals with process analytical technology and how it can be implemented in the meat industry through on-line grading of chemical meat quality. The focus will be on two applications, namely the rapid quality control of fat quality and the development of a method for on-line detection...... of nano-molar quantification in few seconds, in addition to an accelerated extraction-free GC-MS method that through automation can deliver results much faster than other similar methods. The implementation of these high tech methods will provide the meat industry with a leading edge not only with product...... of boar taint. The chemical makeup of fat has a large effect on meat cut quality. Fat quality has traditionally been determined by methylation of a tissue sample followed by chromatography on a GC-MS system, elucidating the composition of the individual fatty acids. As this procedure typically takes far...

  20. Linear polarization measurements at H. beta. of early-type emission line stars

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, D; McLean, I S [Glasgow Univ. (UK)

    1976-02-01

    Linear polarization measurements across the H..beta.. emission lines of the stars ..gamma.. Cas, zeta Tau and 48 Per are presented. For the first two stars there is a marked reduction of the polarization at the centre of the line and for ..gamma.. Cas, this varies from night to night. During the H..beta.. observations of zeta Tau, a change of polarization over tens of minutes was indicated in a monitor channel tuned to the continuum on the blue side of H..beta... For the fainter star, 48 Per, the uncertainties of the polarimetry were increased in relation to ..gamma.. Cas and zeta Tau by a factor of about two and at this precision, no differential effects across the line were recorded. Observations of ..cap alpha.. Cyg are also given to demonstrate the reliability of the polarimeter.

  1. MICROLENSING OF QUASAR BROAD EMISSION LINES: CONSTRAINTS ON BROAD LINE REGION SIZE

    Energy Technology Data Exchange (ETDEWEB)

    Guerras, E.; Mediavilla, E. [Instituto de Astrofisica de Canarias, Via Lactea S/N, La Laguna E-38200, Tenerife (Spain); Jimenez-Vicente, J. [Departamento de Fisica Teorica y del Cosmos, Universidad de Granada, Campus de Fuentenueva, E-18071 Granada (Spain); Kochanek, C. S. [Department of Astronomy and the Center for Cosmology and Astroparticle Physics, The Ohio State University, 4055 McPherson Lab, 140 West 18th Avenue, Columbus, OH 43221 (United States); Munoz, J. A. [Departamento de Astronomia y Astrofisica, Universidad de Valencia, E-46100 Burjassot, Valencia (Spain); Falco, E. [Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Motta, V. [Departamento de Fisica y Astronomia, Universidad de Valparaiso, Avda. Gran Bretana 1111, Valparaiso (Chile)

    2013-02-20

    We measure the differential microlensing of the broad emission lines between 18 quasar image pairs in 16 gravitational lenses. We find that the broad emission lines are in general weakly microlensed. The results show, at a modest level of confidence (1.8{sigma}), that high ionization lines such as C IV are more strongly microlensed than low ionization lines such as H{beta}, indicating that the high ionization line emission regions are more compact. If we statistically model the distribution of microlensing magnifications, we obtain estimates for the broad line region size of r{sub s} = 24{sup +22} {sub -15} and r{sub s} = 55{sup +150} {sub -35} lt-day (90% confidence) for the high and low ionization lines, respectively. When the samples are divided into higher and lower luminosity quasars, we find that the line emission regions of more luminous quasars are larger, with a slope consistent with the expected scaling from photoionization models. Our estimates also agree well with the results from local reveberation mapping studies.

  2. On-line fuel and control rod integrity management in BWRs

    International Nuclear Information System (INIS)

    Larsson, Irina; Sihver, Lembit

    2011-01-01

    Surveillance of fuel and control rod integrity in a BWR core is essential to maintain a safe and reliable operation of a nuclear power plant. An accurate and prompt way to monitor fuel integrity in a reactor core during reactor operation is by using on-line measurements of the gamma emitting noble gas activities in the off-gas system. The integrity of control rods can be efficiently followed by on-line measurements of the helium (He) concentration in the off-gases. This method also gives information about fuel rod failures since He is used as a fill gas in the fuel rods. To survey fuel and control rod integrity during reactor operation, a system consisting of combined gamma and He on-line measurements in the off-gases should be used. Such a system can detect and follow the behavior of fuel and control rod failures. In addition, it can separate fuel failures from control rod failures since fuel rods contain both He and gamma emitting noble gases, while control rods only contain He. Moreover, the system is able to distinguish primary fuel failures from degradation of already existing ones. In this paper we present a combined system for on-line measurements of He and gamma emitting noble gases in the reactor off-gas system and measuring experiences from different BWRs. (author)

  3. Evaluation of an on-line methodology for measuring volatile organic compounds (VOC) fluxes by eddy-covariance with a PTR-TOF-Qi-MS

    Science.gov (United States)

    Loubet, Benjamin; Buysse, Pauline; Lafouge, Florence; Ciuraru, Raluca; Decuq, Céline; Zurfluh, Olivier

    2017-04-01

    Field scale flux measurements of volatile organic compounds (VOC) are essential for improving our knowledge of VOC emissions from ecosystems. Many VOCs are emitted from and deposited to ecosystems. Especially less known, are crops which represent more than 50% of French terrestrial surfaces. In this study, we evaluate a new on-line methodology for measuring VOC fluxes by Eddy Covariance with a PTR-Qi-TOF-MS. Measurements were performed at the ICOS FR-GRI site over a crop using a 30 m long high flow rate sampling line and an ultrasonic anemometer. A Labview program was specially designed for acquisition and on-line covariance calculation: Whole mass spectra ( 240000 channels) were acquired on-line at 10 Hz and stored in a temporary memory. Every 5 minutes, the spectra were mass-calibrated and normalized by the primary ion peak integral at 10 Hz. The mass spectra peaks were then retrieved from the 5-min averaged spectra by withdrawing the baseline, determining the resolution and using a multiple-peak detection algorithm. In order to optimize the peak detection algorithm for the covariance, we determined the covariances as the integrals of the peaks of the vertical-air-velocity-fluctuation weighed-averaged-spectra. In other terms, we calculate , were w is the vertical component of the air velocity, Sp is the spectra, t is time, lag is the decorrelation lag time and denotes an average. The lag time was determined as the decorrelation time between w and the primary ion (at mass 21.022) which integrates the contribution of all reactions of VOC and water with the primary ion. Our algorithm was evaluated by comparing the exchange velocity of water vapor measured by an open path absorption spectroscopy instrument and the water cluster measured with the PTRQi-TOF-MS. The influence of the algorithm parameters and lag determination is discussed. This study was supported by the ADEME-CORTEA COV3ER project (http://www6.inra.fr/cov3er).

  4. Water-vapor absorption line measurements in the 940-nm band by using a Raman-shifted dye laser

    Science.gov (United States)

    Chu, Zhiping; Wilkerson, Thomas D.; Singh, Upendra N.

    1993-01-01

    We report water-vapor absorption line measurements that are made by using the first Stokes radiation (930-982 nm) with HWHM 0.015/cm generated by a narrow-linewidth, tunable dye laser. Forty-five absorption line strengths are measured with an uncertainty of 6 percent and among them are fourteen strong lines that are compared with previous measurements for the assessment of spectral purity of the light source. Thirty air-broadened linewidths are measured with 8 percent uncertainty at ambient atmospheric pressure with an average of 0.101/cm. The lines are selected for the purpose of temperature-sensitive or temperature-insensitive lidar measurements. Results for these line strengths and linewidths are corrected for broadband radiation and finite laser linewidth broadening effects and compared with the high-resolution transmission molecular absorption.

  5. Measurement bias detection with Kronecker product restricted models for multivariate longitudinal data: an illustration with health-related quality of life data from thirteen measurement occasions.

    Science.gov (United States)

    Verdam, Mathilde G E; Oort, Frans J

    2014-01-01

    Application of Kronecker product to construct parsimonious structural equation models for multivariate longitudinal data.A method for the investigation of measurement bias with Kronecker product restricted models.Application of these methods to health-related quality of life data from bone metastasis patients, collected at 13 consecutive measurement occasions.The use of curves to facilitate substantive interpretation of apparent measurement bias.Assessment of change in common factor means, after accounting for apparent measurement bias.Longitudinal measurement invariance is usually investigated with a longitudinal factor model (LFM). However, with multiple measurement occasions, the number of parameters to be estimated increases with a multiple of the number of measurement occasions. To guard against too low ratios of numbers of subjects and numbers of parameters, we can use Kronecker product restrictions to model the multivariate longitudinal structure of the data. These restrictions can be imposed on all parameter matrices, including measurement invariance restrictions on factor loadings and intercepts. The resulting models are parsimonious and have attractive interpretation, but require different methods for the investigation of measurement bias. Specifically, additional parameter matrices are introduced to accommodate possible violations of measurement invariance. These additional matrices consist of measurement bias parameters that are either fixed at zero or free to be estimated. In cases of measurement bias, it is also possible to model the bias over time, e.g., with linear or non-linear curves. Measurement bias detection with Kronecker product restricted models will be illustrated with multivariate longitudinal data from 682 bone metastasis patients whose health-related quality of life (HRQL) was measured at 13 consecutive weeks.

  6. The magnetic field near power lines in the Moscow region: the results of measurements and their analyze

    Directory of Open Access Journals (Sweden)

    Prokofyeva A.S.

    2014-12-01

    Full Text Available The aim: to analyze the real power frequency magnetic field (50 Hz values near power lines. The material. Long-term measurements of the power frequency magnetic field (50 Hz near power lines of 110 kV, 220 kVand 500 kVin the Moscow region. Methods. Measurements were made by tracks which were perpendicular to the wires. Length of tracks was up to 40 m. Sensor of measurer was located on 1.8 m under the ground. General quantity of measurement points were 1103. The results. Was obtained general characteristics of real values of strength of electric field and values of magnetic flux density depending to distance to the projection last wire near power lines. Conclusion. Analysis of the results has the values of the magnetic field of power lines correspond to the Russian rules in all cases. Using additional World Health Organization safety criteria for magnetic fields (the class of carcinogenic risks 2B requires the expansion of the health safety zone 2-3 times.

  7. Reliability of a new method for measuring coronal trunk imbalance, the axis-line-angle technique.

    Science.gov (United States)

    Zhang, Rui-Fang; Liu, Kun; Wang, Xue; Liu, Qian; He, Jia-Wei; Wang, Xiang-Yang; Yan, Zhi-Han

    2015-12-01

    Accurate determination of the extent of trunk imbalance in the coronal plane plays a key role in an evaluation of patients with trunk imbalance, such as patients with adolescent idiopathic scoliosis. An established, widely used practice in evaluating trunk imbalance is to drop a plumb line from the C7 vertebra to a key reference axis, the central sacral vertical line (CSVL) in full-spine standing anterioposterior radiographs, and measuring the distance between them, the C7-CSVL. However, measuring the CSVL is subject to intraobserver differences, is error-prone, and is of poor reliability. Therefore, the development of a different way to measure trunk imbalance is needed. This study aimed to describe a new method to measure coronal trunk imbalance, the axis-line-angle technique (ALAT), which measures the angle at the intersection between the C7 plumb line and an axis line drawn from the vertebral centroid of the C7 to the middle of the superior border of the symphysis pubis, and to compare the reliability of the ALAT with that of the C7-CSVL. A prospective study at a university hospital was used. The patient sample consisted of sixty-nine consecutively enrolled men and women patients, aged 10-18 years, who had trunk imbalance defined as C7-CSVL longer than 20 mm on computed full-spine standing anterioposterior radiographs. Data were analyzed to determine the correlation between C7-CSVL and ALAT measurements and to determine intraobserver and interobserver reliabilities. Using a picture archiving and communication system, three radiologists independently evaluated trunk imbalance on the 69 computed radiographs by measuring the C7-CSVL and by measuring the angle determined by the ALAT. Data were analyzed to determine the correlations between the two measures of trunk imbalance, and to determine intraobserver and interobserver reliabilities of each of them. Overall results from the measurements by the C7-CSVL and the ALAT were significantly moderately correlated

  8. Development and evaluation of a meter for measuring return line fluid flow rates during drilling

    Energy Technology Data Exchange (ETDEWEB)

    Loeppke, G.E.; Schafer, D.M.; Glowka, D.A.; Scott, D.D.; Wernig, M.D. (Sandia National Labs., Albuquerque, NM (United States)); Wright, E.K. (Ktech Corp., Albuquerque, NM (United States))

    1992-06-01

    The most costly problem routinely encountered in geothermal drilling is lost circulation, which occurs when drilling fluid is lost to the formation rather than circulating back to the surface. The successful and economical treatment of lost circulation requires the accurate measurement of drilling fluid flow rate both into and out of the well. This report documents the development of a meter for measuring drilling fluid outflow rates in the return line of a drilling rig. The meter employs a rolling counterbalanced float that rides on the surface of the fluid in the return line. The angle of the float pivot arm is sensed with a pendulum potentiometer, and the height of the float is calculated from this measurement. The float height is closely related to the fluid height and, therefore, the flow rate in the line. The prototype rolling float meter was extensively tested under laboratory conditions in the Wellbore Hydraulics Flow Facility; results from these tests were used in the design of the field prototype rolling float meter. The field prototype meter was tested under actual drilling conditions in August and September 1991 at the Long Valley Exploratory Well near Mammoth Lakes, Ca. In addition, the performance of several other commercially available inflow and outflow meters was evaluated in the field. The tested inflow meters included conventional pump stroke counters, rotary pump speed counters, magnetic flowmeters, and an ultrasonic Doppler flowmeter. On the return flow line, a standard paddlemeter, an acoustic level meter, and the prototype rolling float meter were evaluated for measuring drilling fluid outflow rates.

  9. Denmark's on - line early warning radiation monitoring network

    International Nuclear Information System (INIS)

    Walmod-Larsen, O.; Lippert, J.

    1990-01-01

    In Denmark an emergency response coordination committee was set up to cope with the problems after the Chernobyl accident with participation of all relevant authorities. For help in an emergency situation the ARGOS (Accident Reporting and Guiding Operational System), system will be put into use. The ARGOS emergency evaluation computer system, which has been developed in cooperation with the Danish Environmental Protection Agency, is in operation in connection with the emergency planning for the east region of Denmark with regard to the Swedish nuclear power plant operating at Barseback. Inputs of measurement data are on-line available on data screens for evaluation in the emergency coordination centers, presented on suitable geographical maps, showing iso-contours calculated from the input. In case of an alert situation other systems can be put in operation, f.ex. mobile measuring units from the CDEPA's local, operational emergency centers. Their readings can then be put into the computing system parallel to the on-line stations and be presented by the ARGOS-system for evaluation in the emergency command centers. If another national authority in an alert situation requests a transfer of measurement data, and if this is agreed upon by the competent Danish authority, then the transfer can be arranged from the ARGOS-system, through agreed transmission channels. At present the ARGOS system is being improved and expanded by RNL to cover the whole Danish region and to present measurements from the on-line warning system

  10. The User-friendly On-Line Diffusion Chamber

    CERN Document Server

    Aviles Acosta, Jaime

    2015-01-01

    The On-Line Diffusion Chamber is a stand-alone apparatus built to carry out short-live radiotracer diffusion studies. The availability of the on-demand production of isotopes in the ISOLDE facility, and the design of the apparatus to streamline the implantation process, annealing treatment, ion gun ablation with a tape transport system, and radiation intensity measurement with a Ge gamma detector all in the same apparatus, gives the On-Line Diffusion Chamber a unique ability to studies with short-lived radioisotopes or isomer states that are not possible in any other facility in the world.

  11. Measurement bias detection with Kronecker product restricted models for multivariate longitudinal data : An illustration with health-related quality of life data from thirteen measurement occasions

    NARCIS (Netherlands)

    Verdam, M.G.E.; Oort, F.J.

    2014-01-01

    Highlights: - Application of Kronecker product to construct parsimonious structural equation models for multivariate longitudinal data. - A method for the investigation of measurement bias with Kronecker product restricted models. - Application of these methods to health-related quality of life data

  12. On-Line Metrology with Conoscopic Holography: Beyond Triangulation

    Directory of Open Access Journals (Sweden)

    Ignacio Álvarez

    2009-09-01

    Full Text Available On-line non-contact surface inspection with high precision is still an open problem. Laser triangulation techniques are the most common solution for this kind of systems, but there exist fundamental limitations to their applicability when high precisions, long standoffs or large apertures are needed, and when there are difficult operating conditions. Other methods are, in general, not applicable in hostile environments or inadequate for on-line measurement. In this paper we review the latest research in Conoscopic Holography, an interferometric technique that has been applied successfully in this kind of applications, ranging from submicrometric roughness measurements, to long standoff sensors for surface defect detection in steel at high temperatures.

  13. Inferring phylogenetic networks by the maximum parsimony criterion: a case study.

    Science.gov (United States)

    Jin, Guohua; Nakhleh, Luay; Snir, Sagi; Tuller, Tamir

    2007-01-01

    Horizontal gene transfer (HGT) may result in genes whose evolutionary histories disagree with each other, as well as with the species tree. In this case, reconciling the species and gene trees results in a network of relationships, known as the "phylogenetic network" of the set of species. A phylogenetic network that incorporates HGT consists of an underlying species tree that captures vertical inheritance and a set of edges which model the "horizontal" transfer of genetic material. In a series of papers, Nakhleh and colleagues have recently formulated a maximum parsimony (MP) criterion for phylogenetic networks, provided an array of computationally efficient algorithms and heuristics for computing it, and demonstrated its plausibility on simulated data. In this article, we study the performance and robustness of this criterion on biological data. Our findings indicate that MP is very promising when its application is extended to the domain of phylogenetic network reconstruction and HGT detection. In all cases we investigated, the MP criterion detected the correct number of HGT events required to map the evolutionary history of a gene data set onto the species phylogeny. Furthermore, our results indicate that the criterion is robust with respect to both incomplete taxon sampling and the use of different site substitution matrices. Finally, our results show that the MP criterion is very promising in detecting HGT in chimeric genes, whose evolutionary histories are a mix of vertical and horizontal evolution. Besides the performance analysis of MP, our findings offer new insights into the evolution of 4 biological data sets and new possible explanations of HGT scenarios in their evolutionary history.

  14. An atomic force microscopy-based method for line edge roughness measurement

    Energy Technology Data Exchange (ETDEWEB)

    Fouchier, M.; Pargon, E.; Bardet, B. [CNRS/UJF-Grenoble1/CEA LTM, 17 avenue des Martyrs, 38054 Grenoble cedex 9 (France)

    2013-03-14

    With the constant decrease of semiconductor device dimensions, line edge roughness (LER) becomes one of the most important sources of device variability and needs to be controlled below 2 nm for the future technological nodes of the semiconductor roadmap. LER control at the nanometer scale requires accurate measurements. We introduce a technique for LER measurement based upon the atomic force microscope (AFM). In this technique, the sample is tilted at about 45 Degree-Sign and feature sidewalls are scanned along their length with the AFM tip to obtain three-dimensional images. The small radius of curvature of the tip together with the low noise level of a laboratory AFM result in high resolution images. Half profiles and LER values on all the height of the sidewalls are extracted from the 3D images using a procedure that we developed. The influence of sample angle variations on the measurements is shown to be small. The technique is applied to the study of a full pattern transfer into a simplified gate stack. The images obtained are qualitatively consistent with cross-section scanning electron microscopy images and the average LER values agree with that obtained by critical dimension scanning electron microscopy. In addition to its high resolution, this technique presents several advantages such as the ability to image the foot of photoresist lines, complex multi-layer stacks regardless of the materials, and deep re-entrant profiles.

  15. High resolution measurements and modeling of auroral hydrogen emission line profiles

    Directory of Open Access Journals (Sweden)

    B. S. Lanchester

    Full Text Available Measurements in the visible wavelength range at high spectral resolution (1.3 Å have been made at Longyearbyen, Svalbard (15.8 E,78.2 N during an interval of intense proton precipitation. The shape and Doppler shift of hydrogen Balmer beta line profiles have been compared with model line profiles, using as input ion energy spectra from almost coincident passes of the FAST and DMSP spacecraft. The comparison shows that the simulation contains the important physical processes that produce the profiles, and confirms that measured changes in the shape and peak wave-length of the hydrogen profiles are the result of changing energy input. This combination of high resolution measurements with modeling provides a method of estimating the incoming energy and changes in flux of precipitating protons over Svalbard, for given energy and pitch-angle distributions. Whereas for electron precipitation, information on the incident particles is derived from brightness and brightness ratios which require at least two spectral windows, for proton precipitation the Doppler profile of resulting hydrogen emission is directly related to the energy and energy flux of the incident energetic protons and can be used to gather information about the source region. As well as the expected Doppler shift to shorter wavelengths, the measured profiles have a significant red-shifted component, the result of upward flowing emitting hydrogen atoms.

    Key words. Ionosphere (auroral ionosphere; particle precipitation – Magnetospheric physics (auroral phenomena

  16. High resolution measurements and modeling of auroral hydrogen emission line profiles

    Directory of Open Access Journals (Sweden)

    B. S. Lanchester

    2003-07-01

    Full Text Available Measurements in the visible wavelength range at high spectral resolution (1.3 Å have been made at Longyearbyen, Svalbard (15.8 E,78.2 N during an interval of intense proton precipitation. The shape and Doppler shift of hydrogen Balmer beta line profiles have been compared with model line profiles, using as input ion energy spectra from almost coincident passes of the FAST and DMSP spacecraft. The comparison shows that the simulation contains the important physical processes that produce the profiles, and confirms that measured changes in the shape and peak wave-length of the hydrogen profiles are the result of changing energy input. This combination of high resolution measurements with modeling provides a method of estimating the incoming energy and changes in flux of precipitating protons over Svalbard, for given energy and pitch-angle distributions. Whereas for electron precipitation, information on the incident particles is derived from brightness and brightness ratios which require at least two spectral windows, for proton precipitation the Doppler profile of resulting hydrogen emission is directly related to the energy and energy flux of the incident energetic protons and can be used to gather information about the source region. As well as the expected Doppler shift to shorter wavelengths, the measured profiles have a significant red-shifted component, the result of upward flowing emitting hydrogen atoms.Key words. Ionosphere (auroral ionosphere; particle precipitation – Magnetospheric physics (auroral phenomena

  17. Measurement bias detection with Kronecker product restricted models for multivariate longitudinal data: an illustration with health-related quality of life data from thirteen measurement occasions

    NARCIS (Netherlands)

    Verdam, Mathilde G. E.; Oort, Frans J.

    2014-01-01

    Application of Kronecker product to construct parsimonious structural equation models for multivariate longitudinal data. A method for the investigation of measurement bias with Kronecker product restricted models. Application of these methods to health-related quality of life data from bone

  18. On-line determination of anions in pulp mills by capillary electrophoresis (CE); Tehdasoloissa tapahtuva anionien kapillaarielektroforeettinen on-line maeaeritys ja sen hyoedyntaeminen prosessivalvonnassa - MPKY 02

    Energy Technology Data Exchange (ETDEWEB)

    Kokkonen, R.; Holmberg, M.; Vainikka, V. [Finnish Pulp and Paper Research Institute, Espoo (Finland)

    1998-12-31

    The aim of the study was to set-up a process control system for on-line measurement of certain anions. Typical anions which forms precipitates in pulp and paper mills are oxalate, carbonate and sulphate. Thus it is important to develop a continuous process analyzing system to control concentration levels of this anions. For the preliminary tests of continuous determinations of chloride and sulphate anions in tap water a simple on-line system was build in KCL (The Finnish Pulp and Paper Research Institute) and connected to a capillary electroforesis apparatus. In the preliminary tests a chromate buffer (ph = 7.6) was used. Separation of chloride and sulphate was excellent but the stability of buffer was not good enough and it was usable only for few hours. After experimental studies VTT developed a stable capillary electrophoresis method based on mixed amine buffer and this was selected for an on-line method for determination of anions in process waters of the pulp and paper industry. In the preliminary on-line test (r = 20) repeatabilities of migration times of sulphate and chloride with the chromate buffer were < 5 % (RSD) and peak heights < 15 % (RSD). With the mixed amine buffer repeatabilities were better. The preliminary tests showed that it is possible to connect a capillary electrophoresis system to on-line measurements. For the moment no commercial on-line CE apparatus is available. (orig.)

  19. On-line determination of anions in pulp mills by capillary electrophoresis (CE); Tehdasoloissa tapahtuva anionien kapillaarielektroforeettinen on-line maeaeritys ja sen hyoedyntaeminen prosessivalvonnassa - MPKY 02

    Energy Technology Data Exchange (ETDEWEB)

    Kokkonen, R; Holmberg, M; Vainikka, V [Finnish Pulp and Paper Research Institute, Espoo (Finland)

    1999-12-31

    The aim of the study was to set-up a process control system for on-line measurement of certain anions. Typical anions which forms precipitates in pulp and paper mills are oxalate, carbonate and sulphate. Thus it is important to develop a continuous process analyzing system to control concentration levels of this anions. For the preliminary tests of continuous determinations of chloride and sulphate anions in tap water a simple on-line system was build in KCL (The Finnish Pulp and Paper Research Institute) and connected to a capillary electroforesis apparatus. In the preliminary tests a chromate buffer (ph = 7.6) was used. Separation of chloride and sulphate was excellent but the stability of buffer was not good enough and it was usable only for few hours. After experimental studies VTT developed a stable capillary electrophoresis method based on mixed amine buffer and this was selected for an on-line method for determination of anions in process waters of the pulp and paper industry. In the preliminary on-line test (r = 20) repeatabilities of migration times of sulphate and chloride with the chromate buffer were < 5 % (RSD) and peak heights < 15 % (RSD). With the mixed amine buffer repeatabilities were better. The preliminary tests showed that it is possible to connect a capillary electrophoresis system to on-line measurements. For the moment no commercial on-line CE apparatus is available. (orig.)

  20. HOPI: on-line injection optimization program

    International Nuclear Information System (INIS)

    LeMaire, J.L.

    1977-01-01

    A method of matching the beam from the 200 MeV linac to the AGS without the necessity of making emittance measurements is presented. An on-line computer program written on the PDP10 computer performs the matching by modifying independently the horizontal and vertical emittance. Experimental results show success with this method, which can be applied to any matching section

  1. The Use of Parsimonious Questionnaires in Occupational Health Surveillance: Psychometric Properties of the Short Italian Version of the Effort/Reward Imbalance Questionnaire

    Directory of Open Access Journals (Sweden)

    Nicola Magnavita

    2012-01-01

    Full Text Available Purpose. To perform a parsimonious measurement of workplace psychosocial stress in routine occupational health surveillance, this study tests the psychometric properties of a short version of the original Italian effort-reward imbalance (ERI questionnaire. Methods. 1,803 employees (63 percent women from 19 service companies in the Italian region of Latium participated in a cross-sectional survey containing the short version of the ERI questionnaire (16 items and questions related to self-reported health, musculoskeletal complaints and job satisfaction. Exploratory factor analysis, internal consistency of scales and criterion validity were utilized. Results. The internal consistency of scales was satisfactory. Principal component analysis enabled to identify the model’s main factors. Significant associations with health and job satisfaction in the majority of cases support the notion of criterion validity. A high score on the effort-reward ratio was associated with an elevated odds ratio (OR = 2.71; 95% CI 1.86–3.95 of musculoskeletal complaints in the upper arm. Conclusions. The short form of the Italian ERI questionnaire provides a psychometrically useful tool for routine occupational health surveillance, although further validation is recommended.

  2. The influence of specific mechanical energy on cornmeal viscosity measured by an on-line system during twin-screw extrusion

    Directory of Open Access Journals (Sweden)

    Y. K. CHANG

    1999-09-01

    Full Text Available The influence of specific mechanical energy (SME on cornmeal viscosity during the twin-screw extrusion at feed moisture contents of 25 and 30% and screw speeds in the range from 100 to 500 rpm was measured. Cornmeal was extruded in a co-rotating, intermeshing twin-screw coupled to a slit die rheometer. One approach to the on-line rheological measurement is to use a slit die with the extruder. In the present work it was show that shear viscosity decreased as a function of SME. The viscosity of cornmeal at the exit die was influenced by screw speed, rate of total mass flow, mass temperature inside the extruder and SME. An increase in screw speed resulted in an increase in SME and a decrease in viscosity. A reduction in slit die height and an increase in screw speed and mass temperature led to a remarkable macromolecular degradation of the starch, as evidenced by the decrease in viscosity.

  3. On-line and off-line data analysis for the EUSO-TA experiment

    International Nuclear Information System (INIS)

    Piotrowski, Lech Wiktor; Casolino, Marco; Conti, Livio; Ebisuzaki, Toshikazu; Fornaro, Claudio; Kawasaki, Yoshiya; Hachisu, Yusuke; Ohmori, Hitoshi; De Santis, Cristian; Shinozaki, Kenji; Takizawa, Yoshiyuki; Uehara, Yoshihiro

    2015-01-01

    We show the principles of the communication protocol, on-line calibration, off-line data format as well as basic visualisation and data analysis software implemented for the EUSO-TA on-ground experiment, being the first step towards implementation in a future space based mission. EUSO-TA is an on-ground detector for measuring UV (290–430 nm) light from extensive air showers induced by cosmic rays. It is a prototype experiment for the JEM-EUSO space-borne mission, built according to the same constraints of low mass, low power consumption and thus low computing power. Nevertheless, it needs to process a huge amount of data in short time, taking 2.5μs exposures for 2304 channels. The low processing power and high time resolution require an efficient communication protocol and simple yet powerful algorithms for on-line analysis. The off-line data format is designed for storing a huge amount of data, at the same time allowing easy access, analysis and sharing. Its structure is scalable and adjustable to different experimental designs. It is independent of the data origin, whether it is hardware or a Monte-Carlo simulator. Use of object-oriented techniques and the ROOT framework allows rapid development of dedicated analysis software, such as a Python based quick-view program described herein. Basic capabilities of the software, such as display of the focal surface, light curves and calibration data are shown in this paper

  4. On-line and off-line data analysis for the EUSO-TA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Piotrowski, Lech Wiktor, E-mail: lech.piotrowski@riken.jp [RIKEN, Wako (Japan); Casolino, Marco [RIKEN, Wako (Japan); INFN and Univ. Rome Tor Vergata, Rome (Italy); Conti, Livio [International Telematic University UNINETTUNO, Rome (Italy); Ebisuzaki, Toshikazu [RIKEN, Wako (Japan); Fornaro, Claudio [International Telematic University UNINETTUNO, Rome (Italy); Kawasaki, Yoshiya; Hachisu, Yusuke; Ohmori, Hitoshi [RIKEN, Wako (Japan); De Santis, Cristian [INFN and Univ. Rome Tor Vergata, Rome (Italy); Shinozaki, Kenji [Institute for Astronomy and Astrophysics, Kepler Center, University of Tübingen, Sand 6, D-72076 Tübingen (Germany); RIKEN, Wako (Japan); Takizawa, Yoshiyuki; Uehara, Yoshihiro [RIKEN, Wako (Japan)

    2015-02-11

    We show the principles of the communication protocol, on-line calibration, off-line data format as well as basic visualisation and data analysis software implemented for the EUSO-TA on-ground experiment, being the first step towards implementation in a future space based mission. EUSO-TA is an on-ground detector for measuring UV (290–430 nm) light from extensive air showers induced by cosmic rays. It is a prototype experiment for the JEM-EUSO space-borne mission, built according to the same constraints of low mass, low power consumption and thus low computing power. Nevertheless, it needs to process a huge amount of data in short time, taking 2.5μs exposures for 2304 channels. The low processing power and high time resolution require an efficient communication protocol and simple yet powerful algorithms for on-line analysis. The off-line data format is designed for storing a huge amount of data, at the same time allowing easy access, analysis and sharing. Its structure is scalable and adjustable to different experimental designs. It is independent of the data origin, whether it is hardware or a Monte-Carlo simulator. Use of object-oriented techniques and the ROOT framework allows rapid development of dedicated analysis software, such as a Python based quick-view program described herein. Basic capabilities of the software, such as display of the focal surface, light curves and calibration data are shown in this paper.

  5. Combination of a fast white-light interferometer with a phase shifting interferometric line sensor for form measurements of precision components

    Science.gov (United States)

    Laubach, Sören; Ehret, Gerd; Riebling, Jörg; Lehmann, Peter

    2017-06-01

    By means of an interferometric line sensor system, the form of a specimen can be measured by stitching several overlapping circular subapertures to form one 3D topography. This concept is very flexible and can be adapted to many different specimen geometries. The sensor is based on a Michelson interferometer configuration that consists of a rapidly oscillating reference mirror in combination with a high-speed line-scan camera. Due to the overlapping areas, movement errors of the scan axes can be corrected. In order to automatically adjust the line sensor in such a way that it is perpendicular to the measurement surface at a fixed working distance, a white-light interferometer was included in the line-based form-measuring system. By means of a fast white-light scan, the optimum angle of the sensor (with respect to the surface of the specimen) is determined in advance, before scanning the specimen using the line-based sinusoidal phase shifting interferometer. This produces accurate measurement results and makes it possible to also measure non-rotational specimens. In this paper, the setup of the line-based form-measuring system is introduced and the measurement strategy of the sensor adjustment using an additional white-light interferometer is presented. Furthermore, the traceability chain of the system and the main error influences are discussed. Examples of form measurement results are shown.

  6. Measurement of the 0.511 MeV #betta# ray line from the galactic center

    International Nuclear Information System (INIS)

    Jardim, J.O.D.; Benson, J.L.; Jardim, M.V.A.; Martin, I.M.

    1981-02-01

    The detection of the 0.511 MeV electron-positron annihilation line coming from the Galactic Center can provide the means to estimate the rate of positron production and to test some theoretical sources of positrons. The result of the measurements of the 0.511 MeV line flux made in a gamma-ray experiment on board a stratospheric balloon is presented. Thedetector field of view looked at the galactic longitude range-31 0 0 . The observed flux is (6.70 + - 0.85)x10 - 3 photons cm - 2 s - 1 , which is in good agreement with the expected flux when assuming that the Galactic Center is a line source emitting uniformly. (Author) [pt

  7. High precision wavelength measurements of X-ray lines emitted from TS-Tokamak plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Platz, P. [Association Euratom-CEA, Centre d`Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Cornille, M.; Dubau, J. [Observatoire de Paris, 92 - Meudon (France)

    1996-01-01

    X-ray line spectra from highly charged impurity ions have been taken with a high-resolution Bragg-crystal spectrometer on the Tore Supra (TS) tokamak. By cross-checking the wavelengths of reference lines from the heliumlike ions Ti20 + (2.6 Angstroms) and Ar16 + (3.95 Angstroms) we first demonstrate that it is possible to measure wavelengths with a precision, {lambda}/{delta}{lambda}, of better than 50000. We than determine the wavelengths of n=3 to n=2 transitions of neonlike Ag37+ in the 4 Angstroms spectral range. (authors). 16 refs., 7 figs., 3 tabs.

  8. On-line fouling monitor for heat exchangers

    International Nuclear Information System (INIS)

    Tsou, J.L.

    1995-01-01

    Biological and/or chemical fouling in utility service water system heat exchangers adversely affects operation and maintenance costs, and reduced heat transfer capability can force a power deaerating or even a plant shut down. In addition, service water heat exchanger performance is a safety issue for nuclear power plants, and the issue was highlighted by NRC in Generic Letter 89-13. Heat transfer losses due to fouling are difficult to measure and, usually, quantitative assessment of the impact of fouling is impossible. Plant operators typically measure inlet and outlet water temperatures and flow rates and then perform complex calculations for heat exchanger fouling resistance or ''cleanliness''. These direct estimates are often imprecise due to inadequate instrumentation. Electric Power Research Institute developed and patented an on-line condenser fouling monitor. This monitor may be installed in any location within the condenser; does not interfere with routine plant operations, including on-line mechanical and chemical treatment methods; and provides continuous, real-time readings of the heat transfer efficiency of the instrumented tube. This instrument can be modified to perform on-line monitoring of service water heat exchangers. This paper discusses the design, construction of the new monitor, and algorithm used to calculate service water heat exchanger fouling

  9. Study for on-line system to identify inadvertent control rod drops in PWR reactors using ex-core detector and thermocouple measures

    International Nuclear Information System (INIS)

    Souza, Thiago J.; Medeiros, Jose A.C.C.; Goncalves, Alessandro C.

    2015-01-01

    Accidental control rod drops event in PWR reactors leads to an unsafe operating condition. It is important to quickly identify the rod to minimize undesirable effects in such a scenario. In this event, there is a distortion in the power distribution and temperature in the reactor core. The goal of this study is to develop an on-line model to identify the inadvertent control rod dropped in PWR reactor. The proposed model is based on physical correlations and pattern recognition of ex-core detector responses and thermocouples measures. The results of the study demonstrated the feasibility of an on-line system, contributing to safer operation conditions and preventing undesirable effects, as its shutdown. (author)

  10. Study for on-line system to identify inadvertent control rod drops in PWR reactors using ex-core detector and thermocouple measures

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Thiago J.; Medeiros, Jose A.C.C.; Goncalves, Alessandro C., E-mail: tsouza@nuclear.ufrj.br, E-mail: canedo@lmp.ufrj.br, E-mail: alessandro@nuclear.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2015-07-01

    Accidental control rod drops event in PWR reactors leads to an unsafe operating condition. It is important to quickly identify the rod to minimize undesirable effects in such a scenario. In this event, there is a distortion in the power distribution and temperature in the reactor core. The goal of this study is to develop an on-line model to identify the inadvertent control rod dropped in PWR reactor. The proposed model is based on physical correlations and pattern recognition of ex-core detector responses and thermocouples measures. The results of the study demonstrated the feasibility of an on-line system, contributing to safer operation conditions and preventing undesirable effects, as its shutdown. (author)

  11. The effect of family therapy on the changes in the severity of on-line game play and brain activity in adolescents with on-line game addiction

    Science.gov (United States)

    Han, Doug Hyun; Kim, Sun Mi; Lee, Young Sik; Renshaw, Perry F.

    2015-01-01

    We evaluated whether a brief 3-week family therapy intervention would change patterns of brain activation in response to affection and gaming cues in adolescents from dysfunctional families who met criteria for on-line game addiction. Fifteen adolescents with on-line game addiction and fifteen adolescents without problematic on-line game play and an intact family structure were recruited. Over 3 weeks, families were asked to carry out homework assignments focused on increasing family cohesion for more than 1 hour/day and 4 days/week. Before therapy, adolescents with on-line game addiction demonstrated decreased activity as measured by functional magnetic resonance imaging (fMRI) within the caudate, middle temporal gyrus, and occipital lobe in response to images depicting parental affection and increased activity of the middle frontal and inferior parietal in response scenes from on-line games, relative to healthy comparison subjects. Improvement in perceived family cohesion following 3 weeks of treatment was associated with an increase in the activity of the caudate nucleus in response to affection stimuli and was inversely correlated with changes in on-line game playing time. With evidence of brain activation changes in response to on-line game playing cues and images depicting parental love, the present findings suggest that family cohesion may be an important factor in the treatment of problematic on-line game playing. PMID:22698763

  12. Measuring the sensitivity of a boron-lined ion chamber

    International Nuclear Information System (INIS)

    Barton, D.M.

    1992-03-01

    Boron-lined ion chambers are used to monitor external neutron flux from fissionable materials assembled at the Los Alamos Critical Assembly Experiment Facility. The sensitivity of these chambers must be measured periodically in order to detect changes in filling gas and to evaluate other factors that may affect chamber performance. We delineate a procedure to measure ion chamber response using a particular neutron source ( 239 PuBe) in a particular moderating geometry of polyethylene. We also discuss use of the amplifier, high-voltage power supply, recorders, and scram circuits that comprise the complete ion chamber monitoring system

  13. Measurement of the profile and intensity of the solar He I lambda 584-A resonance line

    Science.gov (United States)

    Maloy, J. O.; Hartmann, U. G.; Judge, D. L.; Carlson, R. W.

    1978-01-01

    The intensity and profile of the helium resonance line at 584 A from the entire disk of the sun was investigated by using a rocket-borne helium-filled spectrometer and a curve-of-growth technique. The line profile was found to be accurately represented by a Gaussian profile with full width at half maximum of 122 + or - 10 mA, while the integrated intensity was measured to be 2.6 + or - 1.3 billion photons/s per sq cm at solar activity levels of F(10.7) = 90.8 x 10 to the -22nd per sq m/Hz and Rz = 27. The measured line width is in good agreement with previous spectrographic measurements, but the integrated intensity is larger than most previous photoelectric measurements. However, the derived line center flux of 20 + or - 10 billion photons/s per sq cm/A is in good agreement with values inferred from airglow measurements.

  14. Production of neutron deficient rare isotope beams at IGISOL; on-line and off-line studies

    NARCIS (Netherlands)

    Huikari, J; Dendooven, P; Jokinen, A; Nieminen, A; Penttila, H; Perajarvi, K; Popov, A; Rinta-Antila, S; Aysto, J

    This article reports on recent on-line yield measurements employing the light-ion and heavy-ion reaction-based ion guide systems and new results on a-recoil ion transport properties in ion guides with and without electric fields. In addition, the presently used ion guide designs for fusion

  15. Effective line intensity measurements of trans-nitrous acid (HONO) of the ν1 band near 3600 cm-1 using laser difference-frequency spectrometer

    Science.gov (United States)

    Maamary, Rabih; Fertein, Eric; Fourmentin, Marc; Dewaele, Dorothée; Cazier, Fabrice; Chen, Changshui; Chen, Weidong

    2017-07-01

    We report on the measurements of the effective line intensities of the ν1 fundamental band of trans-nitrous acid (trans-HONO) in the infrared near 3600 cm-1 (2.78 μm). A home-made widely tunable laser spectrometer based on difference-frequency generation (DFG) was used for this study. The strengths of 28 well-resolved absorption lines of the ν1 band were determined by scaling their absorption intensities to the well referenced absorption line intensity of the ν3 band of trans-HONO around 1250 cm-1 recorded simultaneously with the help of a DFB quantum cascade laser (QCL) spectrometer. The maximum measurement uncertainty of 12% in the line intensities is mainly determined by the uncertainty announced in the referenced line intensities, while the measurement precision in frequency positions of the absorption lines is better than 6×10-4 cm-1. The cross-measurement carried out in the present work allows one to perform intensity calibration using well referenced line parameters.

  16. Velocities of dislocation groups in very thin neutron-irradiated copper single crystals measured by slip line cinematography

    Energy Technology Data Exchange (ETDEWEB)

    Potthoff, H.H. (Technische Univ. Braunschweig (Germany, F.R.). Inst. fuer Metallphysik und Nukleare Festkoerperphysik)

    1983-05-16

    Slip line development on very thin flat single crystals of neutron-irradiated Cu (thickness down to only 15 to 20 ..mu..m, orientation for single glide, yield region, room temperature) is recorded by high-speed cinematography during tensile deformation. In such very thin crystals glide dislocations on the slip plane must be arranged in a rather simple way. Drops in tensile load occuring during initiation of single slip lines at the Lueders band front indicate that in the beginning of a slip line development dislocation groups traverse the whole glide plane in very short times. Evaluating the data measured for the slip line growth v/sub s/ >= 10 cm/s is found for screw dislocations and v/sub e/ >= v/sub s/ for edge dislocations. For later stages on thin crystals and for all stages on thick crystals (>= several 100 ..mu..m) slip line development is much slower and slip line show many cross slip events which then appear to control the mean velocity of the dislocations.

  17. Line facilities outline

    International Nuclear Information System (INIS)

    1998-08-01

    This book deals with line facilities. The contents of this book are outline line of wire telecommunication ; development of line, classification of section of line and theory of transmission of line, cable line ; structure of line, line of cable in town, line out of town, domestic cable and other lines, Optical communication ; line of optical cable, transmission method, measurement of optical communication and cable of the sea bottom, Equipment of telecommunication line ; telecommunication line facilities and telecommunication of public works, construction of cable line and maintenance and Regulation of line equipment ; regulation on technique, construction and maintenance.

  18. Measurement bias detection with Kronecker product restricted models for multivariate longitudinal data: an illustration with health-related quality of life data from thirteen measurement occasions

    Science.gov (United States)

    Verdam, Mathilde G. E.; Oort, Frans J.

    2014-01-01

    Highlights Application of Kronecker product to construct parsimonious structural equation models for multivariate longitudinal data. A method for the investigation of measurement bias with Kronecker product restricted models. Application of these methods to health-related quality of life data from bone metastasis patients, collected at 13 consecutive measurement occasions. The use of curves to facilitate substantive interpretation of apparent measurement bias. Assessment of change in common factor means, after accounting for apparent measurement bias. Longitudinal measurement invariance is usually investigated with a longitudinal factor model (LFM). However, with multiple measurement occasions, the number of parameters to be estimated increases with a multiple of the number of measurement occasions. To guard against too low ratios of numbers of subjects and numbers of parameters, we can use Kronecker product restrictions to model the multivariate longitudinal structure of the data. These restrictions can be imposed on all parameter matrices, including measurement invariance restrictions on factor loadings and intercepts. The resulting models are parsimonious and have attractive interpretation, but require different methods for the investigation of measurement bias. Specifically, additional parameter matrices are introduced to accommodate possible violations of measurement invariance. These additional matrices consist of measurement bias parameters that are either fixed at zero or free to be estimated. In cases of measurement bias, it is also possible to model the bias over time, e.g., with linear or non-linear curves. Measurement bias detection with Kronecker product restricted models will be illustrated with multivariate longitudinal data from 682 bone metastasis patients whose health-related quality of life (HRQL) was measured at 13 consecutive weeks. PMID:25295016

  19. Airplane Ice Detector Based on a Microwave Transmission Line

    Science.gov (United States)

    Ngo, Phong; Arndt, G. Dickey; Carl, James R.

    2004-01-01

    An electronic instrument that could detect the potentially dangerous buildup of ice on an airplane wing is undergoing development. The instrument is based on a microwave transmission line configured as a capacitance probe: at selected spots, the transmission-line conductors are partly exposed to allow any ice and/or liquid water present at those spots to act as predominantly capacitive electrical loads on the transmission line. These loads change the input impedance of the transmission line, as measured at a suitable excitation frequency. Thus, it should be possible to infer the presence of ice and/or liquid water from measurements of the input impedance and/or electrical parameters related to the input impedance. The sensory transmission line is of the microstrip type and thus thin enough to be placed on an airplane wing without unduly disturbing airflow in flight. The sensory spots are small areas from which the upper layer of the microstrip has been removed to allow any liquid water or ice on the surface to reach the transmission line. The sensory spots are spaced at nominal open-circuit points, which are at intervals of a half wavelength (in the transmission line, not in air) at the excitation frequency. The excitation frequency used in the experiments has been 1 GHz, for which a half wavelength in the transmission line is .4 in. (.10 cm). The figure depicts a laboratory prototype of the instrument. The impedance-related quantities chosen for use in this version of the instrument are the magnitude and phase of the scattering parameter S11 as manifested in the in-phase (I ) and quadrature (Q) outputs of the phase detector. By careful layout of the transmission line (including the half-wavelength sensor spacing), one can ensure that the amplitude and phase of the input to the phase detector keep shifting in the same direction as ice forms on one or more of the sensor areas. Although only one transmission-line sensor strip is used in the laboratory version, in a

  20. Coulomb field strength measurement by electro-optic spectral decoding system at the CALIFES beam line

    CERN Document Server

    Pan, R; Lefevre, T; Gillepsie, WA; CERN. Geneva. ATS Department

    2016-01-01

    Electro-optic (EO) techniques are increasingly used for longitudinal bunch profile measurements. A bunch profile monitor, based on electro-optic spectral decoding(EOSD), has been developed and demonstrated on the CALIFES beam line at CERN. The EO response is analysed using a frequency domain description, and two methods for extraction of absolute Coulomb field strengths from the electron bunch are demonstrated. Measurements at field strengths up to 1.3 MV/m agree with the expectation based on independent charge measurements.

  1. Clustering Measurements of broad-line AGNs: Review and Future

    Directory of Open Access Journals (Sweden)

    Mirko Krumpe

    2014-12-01

    Full Text Available Despite substantial effort, the precise physical processes that lead to the growth of super-massive black holes in the centers of galaxies are still not well understood. These phases of black hole growth are thought to be of key importance in understanding galaxy evolution. Forthcoming missions such as eROSITA, HETDEX, eBOSS, BigBOSS, LSST, and Pan-STARRS will compile by far the largest ever Active Galactic Nuclei (AGNs catalogs which will allow us to measure the spatial distribution of AGNs in the universe with unprecedented accuracy. For the first time, AGN clustering measurements will reach a level of precision that will not only allow for an alternative approach to answering open questions in AGN and galaxy co-evolution but will open a new frontier, allowing us to precisely determine cosmological parameters. This paper reviews large-scale clustering measurements of broad line AGNs. We summarize how clustering is measured and which constraints can be derived from AGN clustering measurements, we discuss recent developments, and we briefly describe future projects that will deliver extremely large AGN samples which will enable AGN clustering measurements of unprecedented accuracy. In order to maximize the scientific return on the research fields of AGN and galaxy evolution and cosmology, we advise that the community develops a full understanding of the systematic uncertainties which will, in contrast to today’s measurement, be the dominant source of uncertainty.

  2. Evidence for Broad-Line Region Outflows and Their Impact on Black Hole Mass Measurements

    DEFF Research Database (Denmark)

    Denney, K. D.; Assef, R. J.; Horne, K.

    2012-01-01

    could not be fully and accurately interpreted from the 1D velocity-resolved reverberation signal. From the VDM, an outflow component to the emission remains possible but appears to be in addition to an underlying, disk-like BLR structure consistent in size with the measured reverberation lag. The black...... hole (BH) mass derived from this data is therefore secure from any uncertainties possibly derived from gravitationally unbound gas contributing to the emission. Additionally, we demonstrate that BLR emission from the C IV ¿1549 broad emission line can reliably be used as a virial BH mass estimator...

  3. Spectro web: oscillator strength measurements of atomic absorption lines in the sun and procyon

    International Nuclear Information System (INIS)

    Lobel, A

    2008-01-01

    We update the online SpectroWeb database of spectral standard reference stars with 1178 oscillator strength values of atomic absorption lines observed in the optical spectrum of the Sun and Procyon (α CMi A). The updated line oscillator strengths are measured with best fits to the disk-integrated KPNO-FTS spectrum of the Sun observed between 4000 A and 6800 A using state-of-the-art detailed spectral synthesis calculations. A subset of 660 line oscillator strengths is validated with synthetic spectrum calculations of Procyon observed with ESO-UVES between 4700 A and 6800 A. The new log(gf)-values in SpectroWeb are improvements upon the values offered in the online Vienna Atomic Line Database (VALD). We find for neutral iron-group elements, such as Fe I, Ni I, Cr I, and Ti I, a statistically significant over-estimation of the VALD log((gf)-values for weak absorption lines with normalized central line depths below 15 %. For abundant lighter elements (e.g. Mg I and Ca I) this trend is statistically not significantly detectable, with the exception of Si I for which the log(gf)-values of 60 weak and medium-strong lines are substantially decreased to best fit the observed spectra. The newly measured log(gf)-values are available in the SpectroWeb database at http://spectra.freeshell.org, which interactively displays the observed and computed stellar spectra, together with corresponding atomic line data.

  4. Monitoring on-line system for the lactic fermentation measurement using the integration enzyme sensor; Shusekika koso sensa wo mochiita nyusan hakko keisokuyo onrain monitringu shisutemu

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Masayasu; Kumagaya, Tsuyoshi; Nakajima, Yoichi [Kyushu Institute of Technology, Fukuoka (Japan)

    1999-04-05

    The monitoring on-line system for the lactic fermentation measurement in which the simultaneous measurement of the substrate. Generation was possible was constructed without consuming the culture medium by using soliciting small enzyme sensor and flow injection analysis system integrate. There was the linearity that anyway was also range of concentration of 70mM or less and that it is good on the calibration curve of minute glucose, lactose, and lactic acid sensor. It became clear that it proved that all range of concentration of the substrate of these three which combining with the micro diary system, breaks in the lactic fermentation measurement with the necessity can be measured and not observe the interference by medium components, etc. either. Constructed monitoring on-line system is Lactobacillus delbrueckii and, it was applied to the lactic fermentation process of Lactobacillus lactis. Through the fermentation process for 24 hours, simultaneous measurement of glucose (or lactose) and lactic acid is possible. The measured value agreed well with the result of colorimetric method using the enzyme. (translated by NEDO)

  5. Urban micro-scale flood risk estimation with parsimonious hydraulic modelling and census data

    Directory of Open Access Journals (Sweden)

    C. Arrighi

    2013-05-01

    Full Text Available The adoption of 2007/60/EC Directive requires European countries to implement flood hazard and flood risk maps by the end of 2013. Flood risk is the product of flood hazard, vulnerability and exposure, all three to be estimated with comparable level of accuracy. The route to flood risk assessment is consequently much more than hydraulic modelling of inundation, that is hazard mapping. While hazard maps have already been implemented in many countries, quantitative damage and risk maps are still at a preliminary level. A parsimonious quasi-2-D hydraulic model is here adopted, having many advantages in terms of easy set-up. It is here evaluated as being accurate in flood depth estimation in urban areas with a high-resolution and up-to-date Digital Surface Model (DSM. The accuracy, estimated by comparison with marble-plate records of a historic flood in the city of Florence, is characterized in the downtown's most flooded area by a bias of a very few centimetres and a determination coefficient of 0.73. The average risk is found to be about 14 € m−2 yr−1, corresponding to about 8.3% of residents' income. The spatial distribution of estimated risk highlights a complex interaction between the flood pattern and the building characteristics. As a final example application, the estimated risk values have been used to compare different retrofitting measures. Proceeding through the risk estimation steps, a new micro-scale potential damage assessment method is proposed. This is based on the georeferenced census system as the optimal compromise between spatial detail and open availability of socio-economic data. The results of flood risk assessment at the census section scale resolve most of the risk spatial variability, and they can be easily aggregated to whatever upper scale is needed given that they are geographically defined as contiguous polygons. Damage is calculated through stage–damage curves, starting from census data on building type and

  6. Spectral lines of methane measured up to 2.6 THz at sub-MHz accuracy with a CW-THz photomixing spectrometer: Line positions of rotational transitions induced by centrifugal distortion

    Science.gov (United States)

    Bray, C.; Cuisset, A.; Hindle, F.; Mouret, G.; Bocquet, R.; Boudon, V.

    2017-12-01

    Several Doppler-limited rotational transitions of methane induced by centrifugal distortion have been measured with an unprecedented frequency accuracy using a THz photomixing synthesizer based on a frequency comb. Compared to previous synchrotron based FT-Far-IR measurements of Boudon et al. (Ref. [1]), the accuracy of the line frequency measurements is improved by one order of magnitude; this yields a corresponding increase of two orders of magnitude to the weighting of these transitions in the global fit. The rotational transitions in the ν4 ←ν4 hot band are measured for the first time by the broad spectral coverage of the photomixing CW-THz spectrometer providing access up to R(5) transitions at 2.6 THz. The new global fit including the present lines has been used to update the methane line list of the HITRAN database. Some small, but significant variations of the parameter values are observed and are accompanied by a reduction of the 1-σ uncertainties on the rotational (B0) and centrifugal distortion (D0) constants.

  7. Moving droplets : The measurement of contact lines

    NARCIS (Netherlands)

    Poelma, C.; Franken, M.J.Z.; Kim, H.; Westerweel, J.

    2014-01-01

    Contact lines are the locations where a gas, liquid and a solid meet. From everyday experience we know that such contact lines can be mobile, for example in the case of a water droplet sliding over a glass surface. However, the continuum description of the flow towards or away from a contact line

  8. Prediction of the dynamic response of complex transmission line systems for unsteady pressure measurements

    International Nuclear Information System (INIS)

    Antonini, C; Persico, G; Rowe, A L

    2008-01-01

    Among the measurement and control systems of gas turbine engines, a recent new issue is the possibility of performing unsteady pressure measurements to detect flow anomalies in an engine or to evaluate loads on aerodynamic surfaces. A possible answer to this demand could be extending the use of well known and widely used transmission line systems, which have been applied so far to steady monitoring, to unsteady measurements thanks to proper dynamic modeling and compensation. Despite the huge number of models existing in the literature, a novel method has been developed, which is at the same time easy-to-handle, flexible and capable of reproducing the actual physics of the problem. Furthermore, the new model is able to deal with arbitrary complex networks of lines and cavities, and thus its applicability is not limited to series-connected systems. The main objectives of this paper are to show the derivation of the model, its validation against experimental tests and example of its applicability

  9. On-line pressure measurement using scanning systems

    International Nuclear Information System (INIS)

    Morss, A.G.; Watson, A.P.

    1978-08-01

    Data collection methods can be improved significantly by using pressure scanning systems in conjunction with transducers for the measurement of pressure distribution in fluid flow rigs. However, the response of pressure transducers to the slight random pressure fluctuations that occur in practice can cause some measurement problems, especially for accurate work. The nature of these pressure fluctuations is examined and suitable analysis techniques are recommended. Results obtained using these techniques are presented. It is concluded that by using the correct techniques pressure transducer systems can be used to measure pressure distributions accurately and are sufficiently sensitive to measure very small systematic effects with great precision. (author)

  10. Simultaneous measurement of line electron density and Faraday rotation in the ISX-B tokamak

    International Nuclear Information System (INIS)

    Hutchinson, D.P.; Ma, C.H.; Staats, P.A.; Vander Sluis, K.L.

    1981-01-01

    A new diagnostic system utilizing a submillimetre-wave, phase-modulated polarimeter/interferometer has been used to simultaneously measure the time evolution of the line-averaged electron density and poloidal field-induced Faraday rotation in the ISX-B tokamak. The measurements, performed along four chords of the plasma column, have been correlated with poloidal field changes associated with a ramp in the Ohmic-heating current and by neutral-beam injection. These are the first simultaneous measurements of line electron density and Faraday rotation to be made along a chord of submillimetre laser beam in a tokamak plasma. (author)

  11. [Measurement and analysis of smile line of 62 Han-Chinese].

    Science.gov (United States)

    Hu, Xiu-lian; Heberer, Susanne; Nelson, Katja; Lin, Ye

    2011-11-01

    To analyze smile features in maximum lip-dynamic in Chinese. Sixty-two Han-Chinese, travelling in Germany, with a mean age of 28.5 years were enrolled and photographed. Standardized digital photos were made to measure the height of displayed maxillary gingiva, papilla and tooth during an enjoyment smile. Statistical analysis was performed using Mann-Whitney-U Test and non-parametric analysis. The mean height of tooth display for the central incisors was 10 mm, with no significant difference between the gender (P > 0.05). The mean height of gingival display was 1.3 mm and the mean papilla height was 3.4 mm. There was no significant difference between the genders (P > 0.05). 31% (19/62) of the subjects belonged to high smile line type, 50% (31/62) to medium smile line type and 19% (12/62) to low smile line type. The red esthetics is a paramount factor for Chinese men and women in the esthetic restoration. 81% of the Chinese studied showed various degree of gingival exposure from central incisor to the premolars, which defined the esthetic area for Chinese people. Papilla is a critical parameter for esthetic evaluation and treatment design. The ratio of high smile line in Chinese may be higher than that in Caucasian.

  12. Stochastic rainfall modeling in West Africa: Parsimonious approaches for domestic rainwater harvesting assessment

    Science.gov (United States)

    Cowden, Joshua R.; Watkins, David W., Jr.; Mihelcic, James R.

    2008-10-01

    SummarySeveral parsimonious stochastic rainfall models are developed and compared for application to domestic rainwater harvesting (DRWH) assessment in West Africa. Worldwide, improved water access rates are lowest for Sub-Saharan Africa, including the West African region, and these low rates have important implications on the health and economy of the region. Domestic rainwater harvesting (DRWH) is proposed as a potential mechanism for water supply enhancement, especially for the poor urban households in the region, which is essential for development planning and poverty alleviation initiatives. The stochastic rainfall models examined are Markov models and LARS-WG, selected due to availability and ease of use for water planners in the developing world. A first-order Markov occurrence model with a mixed exponential amount model is selected as the best option for unconditioned Markov models. However, there is no clear advantage in selecting Markov models over the LARS-WG model for DRWH in West Africa, with each model having distinct strengths and weaknesses. A multi-model approach is used in assessing DRWH in the region to illustrate the variability associated with the rainfall models. It is clear DRWH can be successfully used as a water enhancement mechanism in West Africa for certain times of the year. A 200 L drum storage capacity could potentially optimize these simple, small roof area systems for many locations in the region.

  13. The measurement and interpretation of Ne VII spectral line intensity ratios

    International Nuclear Information System (INIS)

    Lang, J.

    1983-03-01

    Results are presented for the measurement, using the branching ratios calibration method, of the spectral intensities of Ne VII lines emitted from a theta-pinch plasma whose electron temperature and density have been found by laser scattering and alternate techniques. (author)

  14. Self-tuning wireless power transmission scheme based on on-line scattering parameters measurement and two-side power matching.

    Science.gov (United States)

    Luo, Yanting; Yang, Yongmin; Chen, Zhongsheng

    2014-04-10

    Sub-resonances often happen in wireless power transmission (WPT) systems using coupled magnetic resonances (CMR) due to environmental changes, coil movements or component degradations, which is a serious challenge for high efficiency power transmission. Thus self-tuning is very significant to keep WPT systems following strongly magnetic resonant conditions in practice. Traditional coupled-mode ways is difficult to solve this problem. In this paper a two-port power wave model is presented, where power matching and the overall systemic power transmission efficiency are firstly defined by scattering (S) parameters. Then we propose a novel self-tuning scheme based on on-line S parameters measurements and two-side power matching. Experimental results testify the feasibility of the proposed method. These findings suggest that the proposed method is much potential to develop strongly self-adaptive WPT systems with CMR.

  15. The on-line beam control and diagnosis system of TARN

    International Nuclear Information System (INIS)

    Takanaka, M.; Watanabe, S.; Chiba, K.; Katayama, T.; Noda, A.

    1982-04-01

    The computer network in TARN is composed of a central main frame computer, two different minicomputers and several microprocessors. It has been used for the beam control and the beam diagnosis; support for adjustment of elements of the transport line and the ring, generation of RF voltage function, measurement of beam profile at RF stacking, on-line measurement of ν:value, and observation of Schottky signal. By the use of this computer system, the operation of TARN has been effectively and steadily performed, and additionally it has contributed to measuring the beam characteristics precisely in the ring. (author)

  16. A method for the measurement of in line pistachio aflatoxin concentration based on the laser induced fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Paghaleh, Soodeh Jamali; Askari, Hassan Ranjbar; Marashi, Seyed Mohammad Bagher; Rahimi, Mojtaba; Bahrampour, Ali Reza

    2015-01-01

    Contamination of pistachio nuts with aflatoxin is one of the most significant issues related to pistachio health and expert. A fast pistachio aflatoxin concentration measurement method based on the laser induced fluorescence spectroscopy (LIFS) is proposed. The proposed method from theoretical and experimental points of view is analyzed. In our experiments XeCl Excimer laser is employed as an Ultra Violet (UV) source (λ=308 nm) and a UV–visible (UV–vis) spectrometer is used for fluorescent emission detection. Our setup is employed to measure the concentration of different type of Aflatoxins in pistachio nuts. Measurements results obtained by the LIFS method are compared with those are measured by the standard HPLC method. Aflatoxins concentrations are in good agreement with those are obtained by the HPLC method. The proposed laser induced fluorescence spectroscopy can be used as an in line aflatoxins concentrations measurement instrument for industrial applications. - Highlights: • XeCl Excimer laser is employed as an UV source for measurement of AFs in pistachio nuts. • Results are compared with those are measured by the standard HPLC method. • LIFS is an online AFs concentration measurement method for industrial applications

  17. Measurement of magnetic fields in the direct proximity of power line conductors

    International Nuclear Information System (INIS)

    Mamishev, A.V.; Russell, B.D.

    1995-01-01

    Modeling and managing of power frequency magnetic fields requires verification of theory with actual measurements. Measurements only at ground level are not always sufficient for comprehensive studies. The technique and the results of three-dimensional mapping of the power frequency magnetic fields high above ground level are presented in this paper. Comparative calculations illustrate relevance and approximations of the existing theoretical approach to field modeling. The influence of harmonics on the elliptical rotation of the magnetic field vector is illustrated. The possibility of use of the magnetic fields for the power line proximity detection is discussed

  18. STUDY OF TRANSMISSION LINES EFFECT ON THE SYSTEM OPERATIONON OF CONTINUOUS AUTOMATIC CAB SIGNALLING

    Directory of Open Access Journals (Sweden)

    O. O. Hololobova

    2014-10-01

    Full Text Available Purpose. To conduct an effect research of the electromagnetic field of high-voltage transmission lines (HVTL (750 kV, 50 Hz on the track circuits and continuous automatic cab signalling (CACS with a signal current of 50 Hz in the areas of convergence and intersection with the transmission lines and to propose possible methods to improve noise immunity of CACS. Methodology. The measurements were performed both by means of car-laboratory and directly on rail lines. During the study the electric field strength in the range of industrial frequency directly under the transmission lines and at the distance from it to the railway lines was measured, as well as the time dependence of CACS codes with signal current frequency of 50 Hz directly under the transmission lines and at a distance from it in the absence of the train and its passing. Findings. The root causes analysis of CACS faults and failures was carried out. The effect of the electromagnetic field of high-voltage transmission lines (750 kV, 50 Hz on the track circuit and CACS with signal current of 50 Hz in the areas of convergence and intersection with the transmission line was investigated. Possible methods to improve noise immunity of CACS were considered. Originality. The effect research of transmission lines (750 kV on the operation of the automatic cab signalling on spans Prishib-Burchatsk and Privolnoye-Yelizarovo, Pridneprovsk railway in places of oblique railroads crossing and transmission lines (750 kV, 50 Hz was conducted. Electric field strength in the range of industrial frequency directly under the transmission lines and at a distance from it to the railway line, as well as the time dependences of ALSN codes with signal current frequency of 50 Hz directly under the transmission lines and at a distance from it in the absence of the train and as its passing were measured. It was found that CACS codes in track circuits under transmission lines are strongly distorted, as strength

  19. Velocities of dislocation groups in very thin neutron-irradiated copper single crystals measured by slip line cinematography

    International Nuclear Information System (INIS)

    Potthoff, H.H.

    1983-01-01

    Slip line development on very thin flat single crystals of neutron-irradiated Cu (thickness down to only 15 to 20 μm, orientation for single glide, yield region, room temperature) is recorded by high-speed cinematography during tensile deformation. In such very thin crystals glide dislocations on the slip plane must be arranged in a rather simple way. Drops in tensile load occuring during initiation of single slip lines at the Lueders band front indicate that in the beginning of a slip line development dislocation groups traverse the whole glide plane in very short times. Evaluating the data measured for the slip line growth v/sub s/ >= 10 cm/s is found for screw dislocations and v/sub e/ >= v/sub s/ for edge dislocations. For later stages on thin crystals and for all stages on thick crystals (>= several 100 μm) slip line development is much slower and slip line show many cross slip events which then appear to control the mean velocity of the dislocations. (author)

  20. Electron temperature measurements by the plasma line technique at the French incoherent scatter radar facilities

    International Nuclear Information System (INIS)

    Kofman, W.; Lejeune, G.; Hagfors, T.; Bauer, P.

    1981-01-01

    The results of experiments aimed at the determination of the electron temperature by a plasma line technique are presented. Using the multistatic capabilities of the French incoherent scatter radar, the plasma line frequencies were simultaneously measured at two receiving stations (Mende and Nancay) at the altitude corresponding to the maximum of the F layer. Different plasma line frequencies are measued because of different effective k vectors that appear in the thermal term of the plasma dispersion relation. We derive and apply two data analysis procedures that enable us to determine this frequency difference. Comparison of this measured frequency difference to that calculated using the ion component electron temperature demonstrates that the plasma lines could indeed be used to determine the electron temperature. A strong dependence of the power in the plasma line as a function of the angle between k vector and magnetic field is observed in agreement with the theory. The future developments of this technique with the EISCAT radar facilities are discussed

  1. A new electrostatic on-line collection-system

    International Nuclear Information System (INIS)

    Dufour, J.P.; Del Moral, R.; Fleury, A.

    1981-06-01

    The working conditions of a new on-line electrostatic collection system are presented. The main charactersitics are high efficiency (reaching 20%) and short delay time (down to the millisecond). The salient features of specific devices for measurements of absolute cross sections, recoil range distributions and angular distributions are given

  2. On-line monitoring system for I-131 manufacturing labs

    International Nuclear Information System (INIS)

    Osovizky, A.; Malamud, Y.; Paran, Y.; Tal, N.; Turgeman, S.; Weinstein, M.

    1997-01-01

    An on-line monitoring and safety system has been installed in a lab for manufacturing 1-131 capsules for nuclear medicine use. Production of up to 100mCi batches is performed in shielded glove boxes. The safety system is based on a unique, 'Medi SMARTS' system (Medical Survey Mapping Automatic Radiation Tracing System), that collects continuously the radiation measurements for processing, display, and storage for future retrieval. Radiation is measured by GM tubes, data is transferred to a data processing unit, and then via a RS-485 communication line to a computer. In addition to the operational advantages and radiation levels storage, the system is being evaluated for the purpose of identifying risky stages in the process. (authors)

  3. Development of an on-line radon monitoring apparatus and design of the on-line radon monitoring platform based on CAN bus

    International Nuclear Information System (INIS)

    Guo Huiping; Lu Ning; Shang Aiguo; Zhou Chunlin; Chen Yingfen; Yu Hongwei

    2004-12-01

    For actual demand, an idea of 'on-line monitoring' is put forward as a way of radon monitoring, instead of traditional so called 'off-line monitoring'. In this way, the apparatus has some automatic functions such as continuous monitoring, real-time alarm; thereby, there is no need for operators' intervention in each monitoring process. With technique of hardware and software design in automation's field, the authors have successfully developed the prototype and finished the scale of it in a standard radon-chamber. This apparatus is composed of detector part and secondary-instrument. The detector part is made up of a passive diffusion collecting chamber, high voltage static electricity, semiconductor detector, charge-sensitive preamplifier and forming circuit. The secondary-instrument is actually a micro-controller system, which consists of a single-chip micro-controller cored measure-controlling unit, display unit, printing unit and alarming unit. Taking this apparatus as a cell, a 'on-line Radon Monitoring Platform' based on CAN bus has been put forward, which can realize multi-points environmental radioactivity real-time monitoring radioactivity and data process. (authors)

  4. On-line fibration measurements in lifting magnets

    International Nuclear Information System (INIS)

    Joas, H.D.

    1993-01-01

    After a solenoid pilot valve had failed to open during a functional test, all of the 17 lifting magnets of the pilot valves were removed, inspected and overhauled during the refuelling of a BWR. Some lifting magnets were found to have deposits between rod (austenitic) and guide sleeve (brass). A relative movement (hammering) between both components was the suspected cause. Measurements confirmed the assumption of a laterally hammering movement of the rods, and also a correlation between acceleration intensity and deposit thickness. Local changes of design or modification of material pairing were suggested as remedial actions. The simulation of measured operation loads was effected on a test rig by means of vibration exciter and the acceleration-time factors known from operation. This resulted in a simple design modification which reduces the impact load between rod and bearing during operation, or else in a suitable material pairing which is optimized for impact load rather than sliding load. Building-up the wear area of the rod was found to interfere least with the existing design. (orig./DG) [de

  5. On-Line Enrichment Monitor for UF{sub 6} Gas Centrifuge Enrichment Plant

    Energy Technology Data Exchange (ETDEWEB)

    Ianakiev, K. D.; Boyer, B.; Favalli, A.; Goda, J. M.; Hill, T.; Keller, C.; Lombardi, M.; Paffett, M.; MacArthur, D. W.; McCluskey, C.; Moss, C. E.; Parker, R.; Smith, M. K.; Swinhoe, M. T. [Los Alamos National Laboratory, Los Alamos (United States)

    2012-06-15

    This paper is a continuation of the Advanced Enrichment Monitoring Technology for UF{sub 6} Gas Centrifuge Enrichment Plant (GCEP) work, presented in the 2010 IAEA Safeguards Symposium. Here we will present the system architecture for a planned side-by-side field trial test of passive (186-keV line spectroscopy and pressure-based correction for UF{sub 6} gas density) and active (186-keV line spectroscopy and transmission measurement based correction for UF{sub 6} gas density) enrichment monitoring systems in URENCO's enrichment plant in Capenhurst. Because the pressure and transmission measurements of UF{sub 6} are complementary, additional information on the importance of the presence of light gases and the UF{sub 6} gas temperature can be obtained by cross-correlation between simultaneous measurements of transmission, pressure and 186-keV intensity. We will discuss the calibration issues and performance in the context of accurate, on-line enrichment measurement. It is hoped that a simple and accurate on-line enrichment monitor can be built using the UF{sub 6} gas pressure provided by the Operator, based on online mass spectrometer calibration, assuming a negligible (a small fraction of percent) contribution of wall deposits. Unaccounted-for wall deposits present at the initial calibration will lead to unwanted sensitivity to changes in theUF{sub 6} gas pressure and thus to error in the enrichment results. Because the accumulated deposits in the cascade header pipe have been identified as an issue for Go/No Go measurements with the Cascade Header Enrichment Monitor (CHEM) and Continuous Enrichment Monitor (CEMO), it is important to explore their effect. Therefore we present the expected uncertainty on enrichment measurements obtained by propagating the errors introduced by deposits, gas density, etc. and will discuss the options for a deposit correction during initial calibration of an On-Line Enrichment Monitor (OLEM).

  6. MHTGR steam generator on-line heat balance, instrumentation and function

    International Nuclear Information System (INIS)

    Klapka, R.E.; Howard, W.W.; Etzel, K.T.; Basol, M.; Karim, N.U.

    1991-09-01

    Instrumentation is used to measure the Modular High Temperature Gas-Cooled Reactor (MHTGR) steam generator dissimilar metal weld temperature during start-up testing. Additional instrumentation is used to determine an on-line heat balance which is maintained during the 40 year module life. In the process of calibrating the on-line heat balance, the helium flow is adjusted to yield the optimum boiling level in the steam generator relative to the dissimilar metal weld. After calibration is complete the weld temperature measurement is non longer required. The reduced boiling level range results in less restrictive steam generator design constraints

  7. Dehydration studies using a novel multichamber microscale fluid bed dryer with in-line near-infrared measurement

    DEFF Research Database (Denmark)

    Räsänen, Eetu; Rantanen, Jukka; Mannermaa, Jukka-Pekka

    2003-01-01

    The purpose of this research was to study the effect of two process parameters (temperature and moisture content) on dehydration behavior of different materials using a novel multichamber microscale fluid bed dryer with a process air control unit and in-line near-infrared (NIR) spectroscopy....... The materials studied were disodium hydrogen phosphates with three different levels of hydrate water and wet theophylline granules. Measured process parameters of fluid bed drying were logged, including in-line NIR signals. Off-line analyses consisted of X-ray powder diffraction patterns, Fourier transform NIR...... spectra and moisture contents of studied materials. During fluid bed drying, the stepwise dehydration of materials was observed by the water content difference of inlet and outlet air, the pressure difference over the bed, and the in-line NIR spectroscopy. The off-line analysis confirmed the state...

  8. Interlaboratory comparison of measuring results of magnetic field near 400 kV overhead power line

    Directory of Open Access Journals (Sweden)

    Grbić Maja

    2012-01-01

    Full Text Available The paper presents a comparison of measured results of magnetic field near 400 kV overhead power lines obtained by three laboratories. This interlaboratory comparison was performed to ensure confidence in the quality of the test results. The measured results were analyzed with standard methods, using En number, based on which the evaluation of the laboratories was performed.

  9. Modified method for intravital-fluorescent microscopy for on-line measurement of vasomotion in cutaneous microcirculation of mice in vivo

    International Nuclear Information System (INIS)

    Traikov, L.; Jia, F.; Ushiyama, A.; Masuda, H.; Ohkubo, C.

    2004-01-01

    The purpose of this study was establishing of the suitable method for long term investigations of changes of the blood vessel diameter up to 60 min continuous measurements with the main aim to be detected possible changes in low frequency component of vasomotion at cutaneous microcirculation of mice in vivo without using anesthetized animals. For investigation of micro-circulatory changes of blood vessel diameter, it is necessary to be used as high as possible quality video images with high resolution (1591x1061 pixels) - at this time the best method for this purpose is intravital microscopy, with high magnification and high resolution this method allows to be observed blood vessels from 5 to 100 μm - and also to be determined blood vessel wall and surrounded blood vessel cells. In this investigation BALB/c mice were used, and a Dorsal Skin-fold Chamber (DSC), were surgically implanted 4 days before the experiment. Intravital video-microscopy measurements of vasomotion in vivo were realized by 3CCD-camera, SONY Inc. and Nikon Inc. microscopy system. Fluorescence signal from the blood vessel, were enhanced by using DVS-3000 system (Hamamatsu Inc.) Vasomotion or temporal changes of the blood vessel diameter was measured by High-speed Digital Machine Vision System CV-2100 (KEYENCE Inc.), using an edge-gap detection algorithm (with a sampling time 389 ms), for on-line calculating the outer diameter of the blood vessels by means of fluorescence-image visualization (with precision 0.5 μm), after caudal vein injection of (from 50h150 μl per 25g animal) Fluorescein Isothiocyanate (FITC)-labeled Dextrans from 60-250 kDa concentration 2.5% in PBS solution pH=7.5. First part of this study was set up the intensity of the fluorescence using different concentrations and molecular weight Dextrans for visualization of the blood plasma with enough high intensity and as low as possible effects on the blood viscosity. Set up of the edge finding algorithm from off-line calculations

  10. A new electrostatic on-line collection-system

    International Nuclear Information System (INIS)

    Dufour, J.P.; Del Moral, R.; Fleury, A.; Hubert, F.; Llabador, Y.; Mauhourat, M.B.; Bimbot, R.; Gardes, D.; Rivet, M.F.

    1981-01-01

    The working conditions of a new on-line electrostatic collection system are presented. The main characteristics are high efficiency (reaching 20%) and short delay time (down to the millisecond). The salient features of specific devices for measurements of absolute cross sections, recoil range distributions and angular distributions are given. (orig.)

  11. Measurements of downwelling far-infrared radiance during the RHUBC-II campaign at Cerro Toco, Chile and comparisons with line-by-line radiative transfer calculations

    Science.gov (United States)

    Mast, Jeffrey C.; Mlynczak, Martin G.; Cageao, Richard P.; Kratz, David P.; Latvakoski, Harri; Johnson, David G.; Turner, David D.; Mlawer, Eli J.

    2017-09-01

    Downwelling radiances at the Earth's surface measured by the Far-Infrared Spectroscopy of the Troposphere (FIRST) instrument in an environment with integrated precipitable water (IPW) as low as 0.03 cm are compared with calculated spectra in the far-infrared and mid-infrared. FIRST (a Fourier transform spectrometer) was deployed from August through October 2009 at 5.38 km MSL on Cerro Toco, a mountain in the Atacama Desert of Chile. There FIRST took part in the Radiative Heating in Unexplored Bands Campaign Part 2 (RHUBC-II), the goal of which is the assessment of water vapor spectroscopy. Radiosonde water vapor and temperature vertical profiles are input into the Atmospheric and Environmental Research (AER) Line-by-Line Radiative Transfer Model (LBLRTM) to compute modeled radiances. The LBLRTM minus FIRST residual spectrum is calculated to assess agreement. Uncertainties (1-σ) in both the measured and modeled radiances are also determined. Measured and modeled radiances nearly all agree to within combined (total) uncertainties. Features exceeding uncertainties can be corrected into the combined uncertainty by increasing water vapor and model continuum absorption, however this may not be necessary due to 1-σ uncertainties (68% confidence). Furthermore, the uncertainty in the measurement-model residual is very large and no additional information on the adequacy of current water vapor spectral line or continuum absorption parameters may be derived. Similar future experiments in similarly cold and dry environments will require absolute accuracy of 0.1% of a 273 K blackbody in radiance and water vapor accuracy of ∼3% in the profile layers contributing to downwelling radiance at the surface.

  12. On-line measurement of magnetic fields at GANIL; Mesures en ligne du champ magnetique du G.A.N.I.L

    Energy Technology Data Exchange (ETDEWEB)

    Lemarie, A

    2008-03-15

    On-line measurement of the magnetic fields of electromagnets at GANIL (France) was studied and developed. This type of measurement is necessary for it allows the adjustment and the monitoring of the parameters which control the transport of particle beams from the accelerators to the experimental vaults. The developments were based on nuclear magnetic resonance (NMR) magnetometers and Hall-effect magnetometers. The limitations of operating NMR probes in inhomogeneous fields required particular solutions. Techniques of positioning and appropriate compensation for field gradients were put in place. NMR probes and Hall-effect probes are integrated into the electronics for monitoring and control according to the defined standards at GANIL. The unit comprises instrumentation which perfectly meets the needs, particularly from the point of view of the measurement and the monitoring of the magnetic parameters. (author)

  13. Measurement of borders in power transmission lines; Medicao de fronteira em linhas de transmissao

    Energy Technology Data Exchange (ETDEWEB)

    Doria, Celso [Bandeirante Energia S.A., Sao Paulo, SP (Brazil)

    2001-07-01

    The creation of Bandeirantes Energia S/A, which is a energy distributor company and at the same time one of the four originated companies from the division of ELETROPAULO Eletricidade S/A, generated the need of consumed energy measurements. Different from a previous situation, which had been accomplished in the 230, 345 and 440 Kv transformer stations. With the aggravating of having been created two distribution companies by this division, which later possessed transmission lines in common finishing a border scenery of 88/138 kv in connection with CTEEP, EPTE, Furnas in station terminals and ELETROPAULO Metropolitana in transmission lines. In order to measure the consumed energy it has been necessary to install meters in all energy entrance subsystems, but there were certain cases for which part of the energy had been absorbed by other distribution company, some times before the connection with Bandeirantes some times after this connection to have been done. For these cases, it has been necessary to install meters at de middle of the line, it means installed meters at the border between the two companies. In February of 1999, they were initiate the studies of viability for these measurements implantation in all of the interface points among Bandeirantes and the other concessionaires, based on the premise that from 01/01/2000 on all the consumed energy by the company should be measured. In the end of May of 1999, with the design final definitions the studies were finished, after that, it has been started the equipment purchases and the actions to hire companies to execute these activities. Finally, in the last week of August of 1999 the construction activities were initiated and the circuits were energized in December of that year.

  14. On-line measurements of RuO{sub 4} during a PWR severe accident

    Energy Technology Data Exchange (ETDEWEB)

    Reymond-Laruinaz, S.; Doizi, D. [CEA, DEN, Departement de Physico-chimie, CEA/Saclay, 91191 Gif sur Yvette Cedex, (France); Manceron, L. [Societe Civile Synchrotron SOLEIL, L' Orme des Merisiers, St-Aubin BP48, 91192 Gif-sur-Yvette Cedex, (France); MONARIS, UMR 8233, Universite Pierre et Marie Curie, 4 Place Jussieu, case 49, F-75252 Paris Cedex 05, (France); Boudon, V. [Laboratoire Interdisciplinaire Carnot de Bourgogne, UMR 6303 CNRS-Universite de Bourgogne, 9 avenue Alain Savary, BP 47870, F-21078 Dijon Cedex, (France); Ducros, G. [CEA, DEN, Departement d' Etudes des Combustibles, CEA/Cadarache, 13108 Saint-Paul-lez-Durance cedex, (France)

    2015-07-01

    After the Fukushima accident, it became essential to have a way to monitor in real time the evolution of a nuclear reactor during a severe accident, in order to react efficiently and minimize the industrial, ecological and health consequences of the accident. Among gaseous fission products, the tetroxide of ruthenium RuO{sub 4} is of prime importance since it has a significant radiological impact. Ruthenium is a low volatile fission product but in case of the rupture of the vessel lower head by the molten corium, the air entering into the vessel oxidizes Ru into gaseous RuO{sub 4}, which is not trapped by the Filtered Containment Venting Systems. To monitor the presence of RuO{sub 4} allows making a diagnosis of the core degradation and quantifying the release into the atmosphere. To determine the presence of RuO{sub 4}, FTIR spectrometry was selected. To study the feasibility of the monitoring, high-resolution IR measurements were realized at the French synchrotron facility SOLEIL on the infrared beam line AILES. Thereafter, theoretical calculations were done to simulate the FTIR spectrum to describe the specific IR fingerprint of the molecule for each isotope and based on its partial pressure in the air. (authors)

  15. Speed dependence of CH335Cl–O2 line-broadening parameters probed on rotational transitions: Measurements and semi-classical calculations

    International Nuclear Information System (INIS)

    Buldyreva, J.; Margulès, L.; Motiyenko, R.A.; Rohart, F.

    2013-01-01

    Relaxation parameters for K-components (K≤6) of six J→J+1 rotational transitions (J=6, 10, 17, 22, 31 and 33) of CH 3 35 Cl perturbed by O 2 are measured at room temperature with Voigt, speed-dependent Voigt and Galatry profiles in order to probe the speed-dependence effects. With respect to the previous study of CH 3 35 Cl–N 2 system [Guinet et al., J Quant Spectrosc Radiat Transfer 2012;113:1113], higher active-gas pressures are reached, providing better signal-to-noise ratios, and the exact expression of the Beer–Lambert law is introduced in the fitting procedure, leading, among other advantages, to much more realistic low-pressure results. The broadening parameters of the considered lines are also computed by a semi-classical method for various relative velocities of colliders and the powers characterizing the dependence of the collisional cross-sections on relative speeds are deduced as functions of the rotational numbers J and K. Additional calculations performed with the Maxwell–Boltzmann distribution of velocities show no significant difference with the earlier results [Buldyreva et al., Phys Chem Chem Phys 2011;13:20326] obtained within the mean thermal velocity approximation. Weighted sums of the presently measured Voigt-profile O 2 -broadening parameters and of the previously published N 2 -broadening ones are calculated to yield experimental air-broadening coefficients for spectroscopic databases. -- Highlights: • Analysis of the speed dependence of relaxation rates of CH 3 Cl lines. • Introduction of the Beer–Lambert law in analysis of line-shapes recorded by FM technique. • Comparison of Maxwell–Boltzmann averaging and mean thermal velocity calculations. • Estimation of air-induced broadening for CH 3 Cl rotational lines

  16. AUTOMATED INSPECTION OF POWER LINE CORRIDORS TO MEASURE VEGETATION UNDERCUT USING UAV-BASED IMAGES

    Directory of Open Access Journals (Sweden)

    M. Maurer

    2017-08-01

    Full Text Available Power line corridor inspection is a time consuming task that is performed mostly manually. As the development of UAVs made huge progress in recent years, and photogrammetric computer vision systems became well established, it is time to further automate inspection tasks. In this paper we present an automated processing pipeline to inspect vegetation undercuts of power line corridors. For this, the area of inspection is reconstructed, geo-referenced, semantically segmented and inter class distance measurements are calculated. The presented pipeline performs an automated selection of the proper 3D reconstruction method for on the one hand wiry (power line, and on the other hand solid objects (surrounding. The automated selection is realized by performing pixel-wise semantic segmentation of the input images using a Fully Convolutional Neural Network. Due to the geo-referenced semantic 3D reconstructions a documentation of areas where maintenance work has to be performed is inherently included in the distance measurements and can be extracted easily. We evaluate the influence of the semantic segmentation according to the 3D reconstruction and show that the automated semantic separation in wiry and dense objects of the 3D reconstruction routine improves the quality of the vegetation undercut inspection. We show the generalization of the semantic segmentation to datasets acquired using different acquisition routines and to varied seasons in time.

  17. Automated Inspection of Power Line Corridors to Measure Vegetation Undercut Using Uav-Based Images

    Science.gov (United States)

    Maurer, M.; Hofer, M.; Fraundorfer, F.; Bischof, H.

    2017-08-01

    Power line corridor inspection is a time consuming task that is performed mostly manually. As the development of UAVs made huge progress in recent years, and photogrammetric computer vision systems became well established, it is time to further automate inspection tasks. In this paper we present an automated processing pipeline to inspect vegetation undercuts of power line corridors. For this, the area of inspection is reconstructed, geo-referenced, semantically segmented and inter class distance measurements are calculated. The presented pipeline performs an automated selection of the proper 3D reconstruction method for on the one hand wiry (power line), and on the other hand solid objects (surrounding). The automated selection is realized by performing pixel-wise semantic segmentation of the input images using a Fully Convolutional Neural Network. Due to the geo-referenced semantic 3D reconstructions a documentation of areas where maintenance work has to be performed is inherently included in the distance measurements and can be extracted easily. We evaluate the influence of the semantic segmentation according to the 3D reconstruction and show that the automated semantic separation in wiry and dense objects of the 3D reconstruction routine improves the quality of the vegetation undercut inspection. We show the generalization of the semantic segmentation to datasets acquired using different acquisition routines and to varied seasons in time.

  18. Monte Carlo aided treatments of the nonlinear inverse PGNAA measurement problem for various continuous on-line applications

    International Nuclear Information System (INIS)

    Gardner, R.P.; Guo, P.; Sood, A.; Mayo, C.W.; Dobbs, C.L.

    1998-01-01

    A review of our work on the application of the PGNAA method as applied to five industrial applications is given. Some introductory material is first given on the importance and use of Monte Carlo simulation in this area, some comments on the place of PGNAA in elemental analysis, and a brief description of the Monte Carlo - Library Least-Squares (MCLLS) approach to the nonlinear inverse PGNAA analysis problem. Then the applications of PGNAA are discussed for: (1) on-line bulk coal analysis, (2) nuclear oil well logging, (3) vitrified waste, (4) the analysis of sodium and aluminium in 'green liquor' in the presence of chlorine, and (5) the conveyor belt sorting of aluminum alloy samples. It is concluded that PGNAA is a rapidly emerging important new technology and measurement approach. (author)

  19. Electron density profile measurements from hydrogen line intensity ratio method in Versatile Experimental Spherical Torus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, YooSung; Shi, Yue-Jiang, E-mail: yjshi@snu.ac.kr; Yang, Jeong-hun; Kim, SeongCheol; Kim, Young-Gi; Dang, Jeong-Jeung; Yang, Seongmoo; Jo, Jungmin; Chung, Kyoung-Jae [Department of Nuclear Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Oh, Soo-Ghee [Division of Energy Systems Research, Ajou University, Suwon 442-749 (Korea, Republic of); Hwang, Y. S. [Department of Nuclear Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Center for Advanced Research in Fusion Reactor Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of)

    2016-11-15

    Electron density profiles of versatile experiment spherical torus plasmas are measured by using a hydrogen line intensity ratio method. A fast-frame visible camera with appropriate bandpass filters is used to detect images of Balmer line intensities. The unique optical system makes it possible to take images of H{sub α} and H{sub β} radiation simultaneously, with only one camera. The frame rate is 1000 fps and the spatial resolution of the system is about 0.5 cm. One-dimensional local emissivity profiles have been obtained from the toroidal line of sight with viewing dumps. An initial result for the electron density profile is presented and is in reasonable agreement with values measured by a triple Langmuir probe.

  20. Research on Poppers Used as Electrical Connectors in High Speed Textile Transmission Lines

    Directory of Open Access Journals (Sweden)

    Leśnikowski Jacek

    2016-12-01

    Full Text Available This paper presents results of research on poppers used as electrical connectors connecting fragments of textile signal lines. These lines can be used in intelligent clothing for connecting electronic modules implemented in it. Intelligent (smart clothing can be used, among others, in the health monitoring of the elderly, newborn babies, or people working in hazardous conditions, for example, firefighters and soldiers. The aim of the present study was to examine the usefulness of poppers, widely used in clothing, as electrical connectors connecting parts of the textile signal lines designed for transmission of high-speed digital signals. The paper presents examples of measured parameters characterizing transmission properties of two fragments of the coplanar, textile transmission line connected to each other using conventional poppers. The presented measurement results contain the so-called s parameters, characteristic impedance of the poppers, and eye measurements characterizing distortions of digital signals passing through the tested line. In the article, the effect of temperature and humidity of air surrounding the tested poppers on their characteristic impedance was also presented. This property and its stability are important in signal lines designed for high-speed data transmission.

  1. Thermal measurement of brake pad lining surfaces during the braking process

    Science.gov (United States)

    Piątkowski, Tadeusz; Polakowski, Henryk; Kastek, Mariusz; Baranowski, Pawel; Damaziak, Krzysztof; Małachowski, Jerzy; Mazurkiewicz, Łukasz

    2012-06-01

    This paper presents the test campaign concept and definition and the analysis of the recorded measurements. One of the most important systems in cars and trucks are brakes. The braking temperature on a lining surface can rise above 500°C. This shows how linings requirements are so strict and, what is more, continuously rising. Besides experimental tests, very supportive method for investigating processes which occur on the brake pad linings are numerical analyses. Experimental tests were conducted on the test machine called IL-68. The main component of IL-68 is so called frictional unit, which consists of: rotational head, which convey a shaft torque and where counter samples are placed and translational head, where samples of coatings are placed and pressed against counter samples. Due to the high rotational speeds and thus the rapid changes in temperature field, the infrared camera was used for testing. The paper presents results of analysis registered thermograms during the tests with different conditions. Furthermore, based on this testing machine, the numerical model was developed. In order to avoid resource demanding analyses only the frictional unit (described above) was taken into consideration. Firstly the geometrical model was performed thanks to CAD techniques, which in the next stage was a base for developing the finite element model. Material properties and boundary conditions exactly correspond to experimental tests. Computations were performed using a dynamic LS-Dyna code where heat generation was estimated assuming full (100%) conversion of mechanical work done by friction forces. Paper presents the results of dynamic thermomechanical analysis too and these results were compared with laboratory tests.

  2. On the Shape of Force-Free Field Lines in the Solar Corona

    KAUST Repository

    Prior, C.

    2012-02-02

    This paper studies the shape parameters of looped field lines in a linear force-free magnetic field. Loop structures with a sufficient amount of kinking are generally seen to form S or inverse S (Z) shapes in the corona (as viewed in projection). For a single field line, we can ask how much the field line is kinked (as measured by the writhe), and how much neighbouring flux twists about the line (as measured by the twist number). The magnetic helicity of a flux element surrounding the field line can be decomposed into these two quantities. We find that the twist helicity contribution dominates the writhe helicity contribution, for field lines of significant aspect ratio, even when their structure is highly kinked. These calculations shed light on some popular assumptions of the field. First, we show that the writhe of field lines of significant aspect ratio (the apex height divided by the footpoint width) can sometimes be of opposite sign to the helicity. Secondly, we demonstrate the possibility of field line structures which could be interpreted as Z-shaped, but which have a helicity value sign expected of an S-shaped structure. These results suggest that caution should be exercised in using two-dimensional images to draw conclusions on the helicity value of field lines and flux tubes. © 2012 Springer Science+Business Media B.V.

  3. Measurements of line overlap for resonant spoiling of x-ray lasing transitions

    International Nuclear Information System (INIS)

    Beiersdorfer, P.; Elliott, S.R.; MacGowan, B.J.; Nilsen, J.

    1994-06-01

    High-precision measurements are presented of candidate line pairs for resonant spoiling of x-ray lasing transitions in the nickel-like W 46+ , the neon-like Fe 16+ , and the neon-like La 47+ x-ray lasers. Our measurements were carried out with high-resolution crystal spectrometers, and a typical precision of 20--50 ppM was achieved. While most resonances appear insufficient for effective photo-spoiling, two resonance pairs are identified that provide a good overlap. These are the 4p 1/2 → 3d 3/2 transition in nickel-like W 46+ with the 2p 3/2 → 1s 1/2 transition in hydrogenic Al 12+ , and the 3s 1/2 → 2p 3/2 transition in neon-like La 47+ with the 1 1 S 0 -2 1 P 1 line in heliumlike Ti 20+

  4. Development of High Temperature Chemistry Measurement System for Establishment of On-Line Water Chemistry Surveillance Network in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Yeon, Jei Won; Kim, Won Ho; Song, Kyu Seok; Joo, Ki Soo; Choi, Ke Chon; Ha, Yeong Keong; Ahn, Hong Joo; Im, Hee Jung; Maeng, Wan Young

    2010-07-01

    An integrated high-temperature water chemistry sensor (pH, E redox ) was developed for the establishment of the on-line water chemistry surveillance system in nuclear power plants. The basic performance of the integrated sensor was confirmed in high-temperature (280 .deg. C, 150kg/m 2 ) lithium borate solutions by using the relationship between the concentration of lithium ion and pH-E redox values. Especially, the effects of various environmental factors such as temperature, pressure, and flow rate on YSZ-based pH electrode were evaluated for ensuring the accuracy of high-temperature pH measurement. And the relationships between each water chemistry factor (pH, redox potential, electrical conductivity) were induced for enhancing the credibility of water chemistry measurement. In addition, on the basis of the evaluation of a nuclear plant design company, we suggested potential installation positions of the measurement system in a nuclear power plant

  5. On-line neutron activation analyzers

    International Nuclear Information System (INIS)

    Flahaut, V.; Colmon, A.

    1999-01-01

    A neutronic analyser has been designed to determine the composition of the flow of raw materials entering a cement factory on the conveyor belt. This new system gives a reliable analysis of the whole cargo that outdates the sampling or the usual surface analysis based on fluorescence spectrometry. The accuracy is about 1%.The neutrons interact with the materials on an average depth of 25 cm and are absorbed by nuclei, these nuclei produce photons whose energy is characteristic of the chemical element itself. The composition can be deduced by measuring the number of photons emitted and their energy. The analysis is made on-line and can concern the search for about 10 compounds. In the case of cement the list of compounds is: SiO 2 , CaO, Al 2 O 3 , Fe 2 O 3 , MgO, Na 2 O, TiO 2 , S, Mn 2 O 3 , K 2 O, and H 2 O. The neutron generator involves a deuterium ion source whose deuterium ions are accelerated by means of an electrical field and impinge on a tritiated target, the nuclear reactions between deuterium and tritium produce 14 MeV neutrons. This neutron analysing technique can be adapted to any need of on-line composition determination. (A.C.)

  6. Size optimization for complex permeability measurement of magnetic thin films using a short-circuited microstrip line up to 30 GHz

    Science.gov (United States)

    Takeda, Shigeru; Naoe, Masayuki

    2018-03-01

    High-frequency permeability spectra of magnetic films were measured over a wideband frequency range of 0.1-30 GHz using a shielded and short-circuited microstrip line jig. In this measurement, spurious resonances had to be suppressed up to the highest frequency. To suppress these resonances, characteristic impedance of the microstrip line should approach 50 Ω at the junction between connector and microstrip line. The main factors dominating these resonances were structures of the jig and the sample. The dimensions were optimized in various experiments, and results demonstrated that the frequency could be raised to at least 20 GHz. For the transverse electromagnetic mode to transmit stably along the microstrip line, the preferred sample was rectangular, with the shorter side parallel to the line and the longer side perpendicular to it, and characteristic impedance strongly depended on the signal line width of the jig. However, too small a jig and sample led to a lower S/N ratio.

  7. Measurements of visible forbidden lines and ion distributions of tungsten highly charged ions at the LHD

    International Nuclear Information System (INIS)

    Kato, D.; Sakaue, H.A.; Murakami, I.; Goto, M.; Morita, S.; Nakamura, N.; Koike, F.; Sasaki, Akira; Ding, X.-B.; Dong, C.-Z.

    2013-01-01

    Visible lines, which are presumably associated with forbidden lines from tungsten highly charged ions, were clearly observed in a spectrum of 370 - 410 nm recorded shortly after a tungsten pellet injection at the LHD. One of the measured lines has been assigned to a magnetic-dipole (M1) line of the ground-term fine-structure transition of W 26+ . Photon emission was observed at 44 lines of sight divided along the vertical direction of a horizontally elongated poloidal cross section of the LHD plasma. The line-integrated intensity of the lines along each line of sight indicates peaked profiles near the plasma center, while visible line emissions of neutral hydrogen and helium recoded in the same sampling time have a maximum located in the peripheral region of the poloidal cross section. (author)

  8. On-line calculation of 3-D power distribution

    International Nuclear Information System (INIS)

    Park, Y. H.; In, W. K.; Park, J. R.; Lee, C. C.; Auh, G. S.

    1996-01-01

    The 3-D power distribution synthesis scheme was implemented in Totally Integrated Core Operation Monitoring System (TICOMS), which is under development as the next generation core monitoring system. The on-line 3-D core power distribution obtained from the measured fixed incore detector readings is used to construct the hot pin power as well as the core average axial power distribution. The core average axial power distribution and the hot pin power of TICOMS were compared with those of the current digital on-line core monitoring system, COLSS, which construct the core average axial power distribution and the pseudo hot pin power. The comparison shows that TICOMS results in the slightly more accurate core average axial power distribution and the less conservative hot pin power. Therefore, these results increased the core operating margins. In addition, the on-line 3-D power distribution is expected to be very useful for the core operation in the future

  9. Assurance of sodium concentration measurement on line in water supply to the secondary system in Atucha I and II nuclear power plants

    International Nuclear Information System (INIS)

    Ormando, Miguel-Angel; Galarza, Guillermo-Dario

    2012-09-01

    Sodium measurement is used for quality control in high purity water application, to monitor break-through of mixed bed ion exchanger, condenser leaks and also to prevent caustic corrosion in turbines. The measurement principle is based on a selective electrode that responds to Nernst equation. The samples were measured in Swan's Trace Sodium/Conductivity Analyzer, Model 2114 July 1993. The aim of this work was to present a method in order to assure sodium concentration measurement on line using the ion selective method for water supply to the secondary system. Conductivity, less sensitive but more reliable than sodium analysis, is an overall quality parameter of water. It is traditionally used to back-up sodium analyzer and is sensitive to any ionic impurities. (authors)

  10. Agent-based station for on-line diagnostics by self-adaptive laser Doppler vibrometry

    Science.gov (United States)

    Serafini, S.; Paone, N.; Castellini, P.

    2013-12-01

    A self-adaptive diagnostic system based on laser vibrometry is proposed for quality control of mechanical defects by vibration testing; it is developed for appliances at the end of an assembly line, but its characteristics are generally suited for testing most types of electromechanical products. It consists of a laser Doppler vibrometer, equipped with scanning mirrors and a camera, which implements self-adaptive bahaviour for optimizing the measurement. The system is conceived as a Quality Control Agent (QCA) and it is part of a Multi Agent System that supervises all the production line. The QCA behaviour is defined so to minimize measurement uncertainty during the on-line tests and to compensate target mis-positioning under guidance of a vision system. Best measurement conditions are reached by maximizing the amplitude of the optical Doppler beat signal (signal quality) and consequently minimize uncertainty. In this paper, the optimization strategy for measurement enhancement achieved by the down-hill algorithm (Nelder-Mead algorithm) and its effect on signal quality improvement is discussed. Tests on a washing machine in controlled operating conditions allow to evaluate the efficacy of the method; significant reduction of noise on vibration velocity spectra is observed. Results from on-line tests are presented, which demonstrate the potential of the system for industrial quality control.

  11. Agent-based station for on-line diagnostics by self-adaptive laser Doppler vibrometry.

    Science.gov (United States)

    Serafini, S; Paone, N; Castellini, P

    2013-12-01

    A self-adaptive diagnostic system based on laser vibrometry is proposed for quality control of mechanical defects by vibration testing; it is developed for appliances at the end of an assembly line, but its characteristics are generally suited for testing most types of electromechanical products. It consists of a laser Doppler vibrometer, equipped with scanning mirrors and a camera, which implements self-adaptive bahaviour for optimizing the measurement. The system is conceived as a Quality Control Agent (QCA) and it is part of a Multi Agent System that supervises all the production line. The QCA behaviour is defined so to minimize measurement uncertainty during the on-line tests and to compensate target mis-positioning under guidance of a vision system. Best measurement conditions are reached by maximizing the amplitude of the optical Doppler beat signal (signal quality) and consequently minimize uncertainty. In this paper, the optimization strategy for measurement enhancement achieved by the down-hill algorithm (Nelder-Mead algorithm) and its effect on signal quality improvement is discussed. Tests on a washing machine in controlled operating conditions allow to evaluate the efficacy of the method; significant reduction of noise on vibration velocity spectra is observed. Results from on-line tests are presented, which demonstrate the potential of the system for industrial quality control.

  12. Application of non-destructive liner thickness measurement technique for manufacturing and inspection process of zirconium lined cladding tube

    International Nuclear Information System (INIS)

    Nakazawa, Norio; Fukuda, Akihiro; Fujii, Noritsugu; Inoue, Koichi

    1986-01-01

    Recently, in order to meet the difference of electric power demand owing to electric power situation, large scale load following operation has become necessary. Therefore, the development of the cladding tubes which withstand power variation has been carried out, as the result, zirconium-lined zircaloy 2 cladding tubes have been developed. In order to reduce the sensitivity to stress corrosion cracking, these zirconium-lined cladding tubes require uniform liner thickness over the whole surface and whole length. Kobe Steel Ltd. developed the nondestructive liner thickness measuring technique based on ultrasonic flaw detection technique and eddy current flaw detection technique. These equipments were applied to the manufacturing and inspection processes of the zirconium-lined cladding tubes, and have demonstrated superiority in the control and assurance of the liner thickness of products. Zirconium-lined cladding tubes, the development of the measuring technique for guaranteeing the uniform liner thickness and the liner thickness control in the manufacturing and inspection processes are described. (Kako, I.)

  13. Comparison between IEEE and CIGRE Thermal Behaviour Standards and Measured Temperature on a 132-kV Overhead Power Line

    Directory of Open Access Journals (Sweden)

    Alberto Arroyo

    2015-12-01

    Full Text Available This paper presents the steady and dynamic thermal balances of an overhead power line proposed by CIGRE (Technical Brochure 601, 2014 and IEEE (Std.738, 2012 standards. The estimated temperatures calculated by the standards are compared with the averaged conductor temperature obtained every 8 min during a year. The conductor is a LA 280 Hawk type, used in a 132-kV overhead line. The steady and dynamic state comparison shows that the number of cases with deviations to conductor temperatures higher than 5 ∘ C decreases from around 20% to 15% when the dynamic analysis is used. As some of the most critical variables are magnitude and direction of the wind speed, ambient temperature and solar radiation, their influence on the conductor temperature is studied. Both standards give similar results with slight differences due to the different way to calculate the solar radiation and convection. Considering the wind, both standards provide better results for the estimated conductor temperature as the wind speed increases and the angle with the line is closer to 90 ∘ . In addition, if the theoretical radiation is replaced by that measured with the pyranometer, the number of samples with deviations higher than 5 ∘ C is reduced from around 15% to 5%.

  14. Neon-like Iron Ion Lines Measured in NIFS/Large Helical Device (LHD) and Hinode/EUV Imaging Spectrometer (EIS)

    Science.gov (United States)

    Watanabe, Tetsuya; Hara, Hirohisa; Murakami, Izumi; Kato, Daiji; Sakaue, Hiroyuki A.; Morita, Shigeru; Suzuki, Chihiro; Tamura, Naoki; Yamamoto, Norimasa; Nakamura, Nobuyuki

    2017-06-01

    Line intensities emerging from the Ne-sequence iron ion (Fe XVII) are measured in the laboratory, by the Large Helical Device at the National Institute for Fusion Science, and in the solar corona by the EUV Imaging Spectrometer (EIS) on board the Hinode mission. The intensity ratios of Fe XVII λ 204.6/λ 254.8 are derived in the laboratory by unblending the contributions of the Fe XIII and XII line intensities. They are consistent with theoretical predictions and solar observations, the latter of which endorses the in-flight radiometric calibrations of the EIS instrument. The still remaining temperature-dependent behavior of the line ratio suggests the contamination of lower-temperature iron lines that are blended with the λ 204.6 line.

  15. Neon-like Iron Ion Lines Measured in NIFS/Large Helical Device (LHD) and Hinode /EUV Imaging Spectrometer (EIS)

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Tetsuya; Hara, Hirohisa [National Astronomical Observatory, National Institutes of Natural Sciences 2-21-1 Osawa Mitaka Tokyo, 181-8588 (Japan); Murakami, Izumi; Kato, Daiji; Morita, Shigeru [SOKENDAI (Graduate University for Advanced Studies) Hayama, Miura-gun, Kanagawa, 240-0193 (Japan); Sakaue, Hiroyuki A.; Suzuki, Chihiro; Tamura, Naoki [National Institute for Fusion Science, National Institutes of Natural Sciences 322-6 Oroshi-cho, Toki Gifu, 509-5292 (Japan); Yamamoto, Norimasa [Chubu University 1200 Matsumoto-cho, Kasugai Aichi, 487-0027 (Japan); Nakamura, Nobuyuki, E-mail: watanabe@uvlab.mtk.nao.ac.jp [The University of Electro-Communications 1-5-1 Chofugaoka, Chofu Tokyo, 182-8585 (Japan)

    2017-06-10

    Line intensities emerging from the Ne-sequence iron ion (Fe xvii) are measured in the laboratory, by the Large Helical Device at the National Institute for Fusion Science, and in the solar corona by the EUV Imaging Spectrometer (EIS) on board the Hinode mission. The intensity ratios of Fe xvii λ 204.6/ λ 254.8 are derived in the laboratory by unblending the contributions of the Fe xiii and xii line intensities. They are consistent with theoretical predictions and solar observations, the latter of which endorses the in-flight radiometric calibrations of the EIS instrument. The still remaining temperature-dependent behavior of the line ratio suggests the contamination of lower-temperature iron lines that are blended with the λ 204.6 line.

  16. Cable line engineering

    International Nuclear Information System (INIS)

    Jang, Hak Sin; Kim, Sin Yeong

    1998-02-01

    This book is about cable line engineering. It is comprised of nine chapters, which deals with summary of cable communication such as way, process of cable communication and optical communication, Line constant of transmission on primary constant, reflection and crosstalk, communication cable line of types like flat cable, coaxial cable and loaded cable, Install of communication line with types and facility of aerial line, construction method of communication line facility, Measurement of communication line, Carrier communication of summary, PCM communication with Introduction, regeneration relay system sampling and quantization and Electric communication service and general information network with mobile communication technique and satellite communication system.

  17. Structural damage diagnosis based on on-line recursive stochastic subspace identification

    International Nuclear Information System (INIS)

    Loh, Chin-Hsiung; Weng, Jian-Huang; Liu, Yi-Cheng; Lin, Pei-Yang; Huang, Shieh-Kung

    2011-01-01

    This paper presents a recursive stochastic subspace identification (RSSI) technique for on-line and almost real-time structural damage diagnosis using output-only measurements. Through RSSI the time-varying natural frequencies of a system can be identified. To reduce the computation time in conducting LQ decomposition in RSSI, the Givens rotation as well as the matrix operation appending a new data set are derived. The relationship between the size of the Hankel matrix and the data length in each shifting moving window is examined so as to extract the time-varying features of the system without loss of generality and to establish on-line and almost real-time system identification. The result from the RSSI technique can also be applied to structural damage diagnosis. Off-line data-driven stochastic subspace identification was used first to establish the system matrix from the measurements of an undamaged (reference) case. Then the RSSI technique incorporating a Kalman estimator is used to extract the dynamic characteristics of the system through continuous monitoring data. The predicted residual error is defined as a damage feature and through the outlier statistics provides an indicator of damage. Verification of the proposed identification algorithm by using the bridge scouring test data and white noise response data of a reinforced concrete frame structure is conducted

  18. Poverty Lines Based on Fuzzy Sets Theory and Its Application to Malaysian Data

    Science.gov (United States)

    Abdullah, Lazim

    2011-01-01

    Defining the poverty line has been acknowledged as being highly variable by the majority of published literature. Despite long discussions and successes, poverty line has a number of problems due to its arbitrary nature. This paper proposes three measurements of poverty lines using membership functions based on fuzzy set theory. The three…

  19. Line width measurement below 60 nm using an optical interferometer and artificial neural network

    Science.gov (United States)

    See, Chung W.; Smith, Richard J.; Somekh, Michael G.; Yacoot, Andrew

    2007-03-01

    We have recently described a technique for optical line-width measurements. The system currently is capable of measuring line-width down to 60 nm with a precision of 2 nm, and potentially should be able to measure down to 10nm. The system consists of an ultra-stable interferometer and artificial neural networks (ANNs). The former is used to generate optical profiles which are input to the ANNs. The outputs of the ANNs are the desired sample parameters. Different types of samples have been tested with equally impressive results. In this paper we will discuss the factors that are essential to extend the application of the technique. Two of the factors are signal conditioning and sample classification. Methods, including principal component analysis, that are capable of performing these tasks will be considered.

  20. Measurement of Line-to-Ground Capacitance in Distribution Network Considering Magnetizing Impedance’s Frequency Characteristic

    Directory of Open Access Journals (Sweden)

    Qing Yang

    2017-04-01

    Full Text Available Signal injection method (SIM is widely applied to the insulation parameters’ measurement in distribution network for its convenience and safety. It can be divided into two kinds of patterns: injecting a specific frequency signal or several frequencies’ groups, and scanning frequency in a scheduled frequency scope. In order to avoid the disadvantages in related researches, improved signal injection method (ISIM, in which the frequency characteristic of the transformer magnetizing impedance is taken into consideration, is proposed. In addition, optimization for signal injection position has been accomplished, and the corresponding three calculation methods of line-to-ground capacitance has been derived. Calculations are carried out through the vector information (vector calculation method, the amplitude information (amplitude calculation method, the phase information (phase calculation method of voltage and current in signal injecting port, respectively. The line-to-ground capacitance is represented by lumped parameter capacitances in high-voltage simulation test. Eight different sinusoidal signals are injected into zero-sequence circuit, and then line-to-ground capacitance is calculated with the above-mentioned vector calculation method based on the voltage and the current data of the injecting port. The results obtained by the vector calculation method show that ISIM has a wider application frequency range compared with signal injection method with rated parameters (RSIM and SIM. The RSIM is calculated with the rated transformer parameters of magnetizing impedance, and the SIM based on the ideal transformer model, and the relative errors of calculation results of ISIM are smaller than that for other methods in general. The six groups of two-frequency set are chosen in a specific scope which is recommended by vector calculation results. Based on ISIM, the line-to-ground capacitance calculations through the amplitude calculation method and

  1. Systematic comparison between line integrated densities measured with interferometry and polarimetry at JET

    International Nuclear Information System (INIS)

    Brombin, M.; Zilli, E.; Giudicotti, L.; Boboc, A.; Murari, A.

    2009-01-01

    A systematic comparison between the line integrated electron density derived from interferometry and polarimetry at JET has been carried out. For the first time the reliability of the measurements of the Cotton-Mouton effect has been analyzed for a wide range of main plasma parameters and the possibility to evaluate the electron density directly from polarimetric data has been studied. The purpose of this work is to recover the interferometric data with the density derived from the measured Cotton-Mouton effect, when the fringe jump phenomena occur. The results show that the difference between the line integrated electron density from interferometry and polarimetry is with one fringe (1.143x10 19 m -2 ) for more than 90% of the cases. It is possible to consider polarimetry as a satisfactory alternative method to interferometry to measure the electron density and it could be used to recover interferometric signal when a fringe jumps occurs, preventing difficulties for the real-time control of many experiments at the JET machine.

  2. On-line control of nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Parus, I.; Kierzek, J.; Zoltowski, T.

    1977-01-01

    The development trends in the field of chemical processes control and the present state of the development of continuous composition analysers has been described. On this background the peculiarities of on-line control methods for spent nuclear fuel reprocessing have been discussed. The measuring methods for direct and indirect determination of chemical composition and nuclear safety are reviewed in detail. The review comprises such methods as: measurement of α, γ and neutron radiation emitted both by nuclides present in technological solutions and using external sources of different radiation, X-ray fluorescence, measurements of physicochemical parameters connected with the composition (pH, density, electrical conductivity), polarography and spectrophotometry. At the end of this review some new trends in process control based on dynamic process models have been presented. (author)

  3. Transmission of radioiodine through sampling lines

    International Nuclear Information System (INIS)

    Unrein, P.J.; Pelletier, C.A.; Cline, J.E.; Voilleque, P.G.

    1985-01-01

    An experimental program to measure radioiodine transmission through sampling lines is described. The transmission depends upon both deposition on and resuspension from the walls of the line. The deposition and resuspension processes are themselves controlled by the length, diameter, and material of the line and the conditions under which it is operated. The operating conditions under study are sampling flow rate, temperature and relative humidity. Measurement results have been interpreted in terms of a four-compartment model of radioiodine deposition and resuspension. The model is applied to each of twenty or more segments of the line. Experimental measurements of short-term transmission fractions and the deposition velocities derived from them are presented for six lines. Data on resuspension rates for the same lines were obtained and are also discussed

  4. Tar formation in a steam-O2 blown CFB gasifier and a steam blown PBFB gasifier (BabyHPR) : Comparison between different on-line measurement techniques and the off-line SPA sampling and analysis method

    NARCIS (Netherlands)

    Meng, X.; Mitsakis, P.; Mayerhofen, M.; De Jong, W.; Gaderer, M.; Verkooijen, A.H.M.; Spliethoff, H.

    2012-01-01

    Two on-line tar measurement campaigns were carried out using an atmospheric pressure 100 “”kWth steam-O2 blown circulating fluidized bed (CFB) gasifier at the Delft University of Technology (TUD) and a 30–40kWth steam blown pressurized bubbling fluidized bed (PBFB) gasifier BabyHPR (Heatpipe

  5. Inexpensive on-line alcohol sensor for fermentation monitoring and control

    Energy Technology Data Exchange (ETDEWEB)

    Birch, S W; Turner, A P.F.; Ashby, R E

    1987-01-01

    An inorganic electrochemical fuel cell sensor was interfaced to a microcomputer and used to measure on-line the alcohol concentration in the off-gas of a fermentor. A calibration curve was obtained for methanol (linear range 0-9 g/l) and ethanol (linear range 0-6 g/l) to relate the alcohol concentration in the fermentor liquid with that in the off-gas. The consumption of methanol in a batch fermentation of the methylotroph Ps.BB1 was monitored (sampling frequency of 5 minutes) and compared with samples taken for off-line analysis by GLC. On-line control of the methanol concentration in a fed-batch fermentation was achieved by proportional and integral control. 24 references.

  6. High-precision drop shape analysis (HPDSA) of quasistatic contact angles on silanized silicon wafers with different surface topographies during inclining-plate measurements: Influence of the surface roughness on the contact line dynamics

    International Nuclear Information System (INIS)

    Heib, F.; Hempelmann, R.; Munief, W.M.; Ingebrandt, S.; Fug, F.; Possart, W.; Groß, K.; Schmitt, M.

    2015-01-01

    Highlights: • Analysis of the triple line motion on surfaces with nanoscale surface topographies. • Analysis of the triple line motion is performed in sub-pixel resolution. • A special fitting and statistical approach for contact angle analysis is applied. • The analyses result set of contact angle data which is independent of “user-skills”. • Characteristically density distributions in dependence on the surface properties. - Abstract: Contact angles and wetting of solid surfaces are strongly influenced by the physical and chemical properties of the surfaces. These influence quantities are difficult to distinguish from each other if contact angle measurements are performed by measuring only the advancing θ a and the receding θ r contact angle. In this regard, time-dependent water contact angles are measured on two hydrophobic modified silicon wafers with different physical surface topographies. The first surface is nearly atomically flat while the second surface is patterned (alternating flat and nanoscale rough patterns) which is synthesized by a photolithography and etching procedure. The different surface topographies are characterized with atomic force microscopy (AFM), Fourier transform infrared reflection absorption spectroscopy (FTIRRAS) and Fourier transform infrared attenuated total reflection spectroscopy (FTIR-ATR). The resulting set of contact angle data obtained by the high-precision drop shape analysis approach is further analyzed by a Gompertzian fitting procedure and a statistical counting procedure in dependence on the triple line velocity. The Gompertzian fit is used to analyze overall properties of the surface and dependencies between the motion on the front and the back edge of the droplets. The statistical counting procedure results in the calculation of expectation values E(p) and standard deviations σ(p) for the inclination angle φ, contact angle θ, triple line velocity vel and the covered distance of the triple line dis

  7. High-precision drop shape analysis (HPDSA) of quasistatic contact angles on silanized silicon wafers with different surface topographies during inclining-plate measurements: Influence of the surface roughness on the contact line dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Heib, F., E-mail: f.heib@mx.uni-saarland.de [Department of Physical Chemistry, Saarland University, 66123 Saarbrücken (Germany); Hempelmann, R. [Department of Physical Chemistry, Saarland University, 66123 Saarbrücken (Germany); Munief, W.M.; Ingebrandt, S. [Department of Informatics and Microsystem Technology, University of Applied Sciences, Kaiserslautern, 66482 Zweibrücken (Germany); Fug, F.; Possart, W. [Department of Adhesion and Interphases in Polymers, Saarland University, 66123 Saarbrücken (Germany); Groß, K.; Schmitt, M. [Department of Physical Chemistry, Saarland University, 66123 Saarbrücken (Germany)

    2015-07-01

    Highlights: • Analysis of the triple line motion on surfaces with nanoscale surface topographies. • Analysis of the triple line motion is performed in sub-pixel resolution. • A special fitting and statistical approach for contact angle analysis is applied. • The analyses result set of contact angle data which is independent of “user-skills”. • Characteristically density distributions in dependence on the surface properties. - Abstract: Contact angles and wetting of solid surfaces are strongly influenced by the physical and chemical properties of the surfaces. These influence quantities are difficult to distinguish from each other if contact angle measurements are performed by measuring only the advancing θ{sub a} and the receding θ{sub r} contact angle. In this regard, time-dependent water contact angles are measured on two hydrophobic modified silicon wafers with different physical surface topographies. The first surface is nearly atomically flat while the second surface is patterned (alternating flat and nanoscale rough patterns) which is synthesized by a photolithography and etching procedure. The different surface topographies are characterized with atomic force microscopy (AFM), Fourier transform infrared reflection absorption spectroscopy (FTIRRAS) and Fourier transform infrared attenuated total reflection spectroscopy (FTIR-ATR). The resulting set of contact angle data obtained by the high-precision drop shape analysis approach is further analyzed by a Gompertzian fitting procedure and a statistical counting procedure in dependence on the triple line velocity. The Gompertzian fit is used to analyze overall properties of the surface and dependencies between the motion on the front and the back edge of the droplets. The statistical counting procedure results in the calculation of expectation values E(p) and standard deviations σ(p) for the inclination angle φ, contact angle θ, triple line velocity vel and the covered distance of the triple

  8. Grounding line processes on the Totten Glacier

    Science.gov (United States)

    Cook, S.; Watson, C. S.; Galton-Fenzi, B.; Peters, L. E.; Coleman, R.

    2017-12-01

    The Totten Glacier has been an area of recent interest due to its large drainage basin, much of which is grounded below sea level and has a history of large scale grounding line movement. Reports that warm water reaches the sub-ice shelf cavity have led to speculation that it could be vulnerable to future grounding line retreat. Over the Antarctic summer 2016/17 an array of 6 GPS and autonomous phase-sensitive radar (ApRES) units were deployed in the grounding zone of the Totten Glacier. These instruments measure changes in ice velocity and thickness which can be used to investigate both ice dynamics across the grounding line, and the interaction between ice and ocean in the subglacial cavity. Basal melt rates calculated from the ApRES units on floating ice range from 1 to 17 m/a. These values are significantly lower than previous estimates of basal melt rate produced by ocean modelling of the subglacial cavity. Meanwhile, GPS-derived velocity and elevation on the surface of the ice show a strong tidal signal, as does the vertical strain rate within the ice derived from internal layering from the ApRES instruments. These results demonstrate the significance of the complex grounding pattern of the Totten Glacier. The presence of re-grounding points has significant implications for the dynamics of the glacier and the ocean circulation within the subglacial cavity. We discuss what can be learned from our in situ measurements, and how they can be used to improve models of the glacier's future behaviour.

  9. Microfluidic electrochemical sensor for on-line monitoring of aerosol oxidative activity.

    Science.gov (United States)

    Sameenoi, Yupaporn; Koehler, Kirsten; Shapiro, Jeff; Boonsong, Kanokporn; Sun, Yele; Collett, Jeffrey; Volckens, John; Henry, Charles S

    2012-06-27

    Particulate matter (PM) air pollution has a significant impact on human morbidity and mortality; however, the mechanisms of PM-induced toxicity are poorly defined. A leading hypothesis states that airborne PM induces harm by generating reactive oxygen species in and around human tissues, leading to oxidative stress. We report here a system employing a microfluidic electrochemical sensor coupled directly to a particle-into-liquid sampler (PILS) system to measure aerosol oxidative activity in an on-line format. The oxidative activity measurement is based on the dithiothreitol (DTT) assay, where, after being oxidized by PM, the remaining reduced DTT is analyzed by the microfluidic sensor. The sensor consists of an array of working, reference, and auxiliary electrodes fabricated in a poly(dimethylsiloxane)-based microfluidic device. Cobalt(II) phthalocyanine-modified carbon paste was used as the working electrode material, allowing selective detection of reduced DTT. The electrochemical sensor was validated off-line against the traditional DTT assay using filter samples taken from urban environments and biomass burning events. After off-line characterization, the sensor was coupled to a PILS to enable on-line sampling/analysis of aerosol oxidative activity. Urban dust and industrial incinerator ash samples were aerosolized in an aerosol chamber and analyzed for their oxidative activity. The on-line sensor reported DTT consumption rates (oxidative activity) in good correlation with aerosol concentration (R(2) from 0.86 to 0.97) with a time resolution of approximately 3 min.

  10. Quasi-Optical Transmission Lines for ECRH on TJ-II Stellarator

    International Nuclear Information System (INIS)

    Fernandez, A.; Likin, K.; Martin, R.; Cappa, A.; Cepero, J.R.

    1999-01-01

    Two mirror lines are used to transmit ht microwave power from the powerful microwave generators to the TJ-II plasmas. Both lines have been tested at nominal power level and they are now in operation. This paper is devoted to the final design of the transmission lines and their testing. Before starting operation at high power level measurements of the wave beam parameters at low power level were made. Two horn antennae were designed to simulate the gyrotron output. Numerical simulations of the far field radiation pattern of the antennae were made, a computer code based on Huygens diffraction theory was developed to simulate the propagation of the beam along a mirror line. A comparison of the theoretical and the experimental results is also presented here. (Author)

  11. The effect of lignite quality variation on the efficiency of on-line ash analyzers

    Energy Technology Data Exchange (ETDEWEB)

    Galetakis, Michael J. [Technical University of Crete, Dept. of Mineral Resources Engineering, University Campus, 73 100 Hania (Greece); Pavloudakis, Francis F. [Public Power Corporation SA, General Division of Mines, Kifisou and Dyrrahiou 89, 104 43 Athens (Greece)

    2009-12-01

    A sustainable coal industry needs to achieve a number of objectives including improvements in utilization of deposits, energy efficiency, and environmental performance during combustion. The ''Clean Coal Concept'' promises to combine the secure and low cost electricity supply offered by hard coal and lignite with adequate environmental precautions. In this context, modern quality control systems, which are greatly based on the on-line analyzers, play an important role in achieving sustainability targets. This paper examines the possibility of using commercial on-line analysis systems for monitoring the mineral matter content of low quality lignite mined from the lignite basin of Megalopolis, Peloponnese, Greece. The effect of the accuracy of the on-line analyzers to process control, when used for the characterization of low rank coals with complex and variable composition, is investigated by carrying out numerous bench- and pilot-scale trials. Pilot-scale trials were based on a dual energy gamma-ray transmission analyzer, which was installed on the conveyor belt that transports lignite from the mine pit to the homogenization stockyard. All measurement data were compared to data gathered during the realisation of similar trials in the lignite mines of Ptolemais Basin, Northern Greece. Results indicated that the accuracy of the on-line measurements was not satisfactory and did not allow lignite quality monitoring in real time. The achieved inferior accuracy of the on-line measurement's accuracy, compared to previous applications at other mining sites, was related to the intense variation of the mineral matter content of lignite and lignite composition, which distorted the calibration of the analyzer. The latter is based on certain assumptions regarding the average mass absorption coefficient of the organic and mineral matter contained in the lignite. Further experimental work is needed to investigate solutions for successful implementation of

  12. An FPGA-Integrated Time-to-Digital Converter Based on a Ring Oscillator for Programmable Delay Line Resolution Measurement

    Directory of Open Access Journals (Sweden)

    Chao Chen

    2014-01-01

    Full Text Available We describe the architecture of a time-to-digital converter (TDC, specially intended to measure the delay resolution of a programmable delay line (PDL. The configuration, which consists of a ring oscillator, a frequency divider (FD, and a period measurement circuit (PMC, is implemented in a field programmable gate array (FPGA device. The ring oscillator realized in loop containing a PDL and a look-up table (LUT generates periodic oscillatory pulses. The FD amplifies the oscillatory period from nanosecond range to microsecond range. The time-to-digital conversion is based on counting the number of clock cycles between two consecutive pulses of the FD by the PMC. Experiments have been conducted to verify the performance of the TDC. The achieved relative errors for four PDLs are within 0.50%–1.21% and the TDC has an equivalent resolution of about 0.4 ps.

  13. Micro-PIXE line-scan measurements of the yellow eel's otolith

    International Nuclear Information System (INIS)

    Zheng, Y.; Guo, H.; Tang, W.; Wei, K.; Shen, H.; Yang, M.; Mi, Y.

    2011-01-01

    Anguilla japonica has a high economic value. The abundance had decreased significantly due to excessive fishing and change in the aquatic ecology. Life history patterns of A. japonica have been studied to prevent excessive fishing and make management plans. Strontium (Sr)-calcium (Ca) ratio along a line down the long axis from the core to the edge of the yellow eel's otolith was measured using micro proton induced X-ray emission (micro-PIXE). An efficient and precise method was proposed to locate the core where an otolith begins to grow, based on Sr concentration and distribution. Using this method, life history patterns of the yellow eels collected from Jingjiang River in China were investigated. In general, there are two types, river eels and estuarine eels.

  14. An OCD perspective of line edge and line width roughness metrology

    Science.gov (United States)

    Bonam, Ravi; Muthinti, Raja; Breton, Mary; Liu, Chi-Chun; Sieg, Stuart; Seshadri, Indira; Saulnier, Nicole; Shearer, Jeffrey; Patlolla, Raghuveer; Huang, Huai

    2017-03-01

    Metrology of nanoscale patterns poses multiple challenges that range from measurement noise, metrology errors, probe size etc. Optical Metrology has gained a lot of significance in the semiconductor industry due to its fast turn around and reliable accuracy, particularly to monitor in-line process variations. Apart from monitoring critical dimension, thickness of films, there are multiple parameters that can be extracted from Optical Metrology models3. Sidewall angles, material compositions etc., can also be modeled to acceptable accuracy. Line edge and Line Width roughness are much sought of metrology following critical dimension and its uniformity, although there has not been much development in them with optical metrology. Scanning Electron Microscopy is still used as a standard metrology technique for assessment of Line Edge and Line Width roughness. In this work we present an assessment of Optical Metrology and its ability to model roughness from a set of structures with intentional jogs to simulate both Line edge and Line width roughness at multiple amplitudes and frequencies. We also present multiple models to represent roughness and extract relevant parameters from Optical metrology. Another critical aspect of optical metrology setup is correlation of measurement to a complementary technique to calibrate models. In this work, we also present comparison of roughness parameters extracted and measured with variation of image processing conditions on a commercially available CD-SEM tool.

  15. Simultaneous measure of a spectral line profile and the apparatus function of a Fabry-Perot spectrometer when continuous background is present

    International Nuclear Information System (INIS)

    Moreno, J.M.; Quintanilla, M.; Mar, S.

    1978-01-01

    A deconvolution method of registered profile on a Fabry-Perot spectrometer is developed, when the actual profile of the source is a Voigt pattern together with a continuous background. The reliability and accuracy of the method is tested with theoreticaly simulated profiles. The method is applied both to measure the real line profiles and to find the Fabry-Perot parameters, as a test of its validity on studies of experimental profiles. Both measure types -source profile and apparatus function- are made simultaneously by means of analysis of the variations of registered profile, at 6438.5A Cd line and 6328A He-Ne laser line, varying the optical path between interferometer mirrors. (author) [es

  16. Computation and measurement of a plasma temperature using the emission lines of copper

    International Nuclear Information System (INIS)

    Sassi, M.; Pierre, L.; Benard, J.; Cahen, C.

    1994-01-01

    The use of copper emission lines for temperature measurement in plasma environments is presented. The article features the problems encountered with such a measurement method when used in a stationary and a non-stationary plasma. In the first case, we were concerned with the temperature measurements in the jet of a 2 MW industrial plasma torche. The plasma was stationary and the measurement geometry allowed the use of the Abel inversion method to recover the temperature profiles in the plasma jet. The limitations of the measurement method on the jet boundaries as well as the cooling of the plasma by entrainement of cold air are discussed. In the second case, a non-stationary plasma in a 1.4 MW electric furnace was studied. This study allowed to feature the role of the detector dynamics as related to the dynamics of the observed medium. The obtained measurements show only a probable temperature in the immediate proximity of the arc. Finally, we conclude on the validity of copper as a tracer and the use of spontaneous emission spectroscopy, and easy method to implement, compared to other sophisticated temperature measurement methods. (orig.)

  17. 4He abundances: Optical versus radio recombination line measurements

    Science.gov (United States)

    Balser, Dana S.; Rood, Robert T.; Bania, T. M.

    2010-04-01

    Accurate measurements of the 4He/H abundance ratio are important in constraining Big Bang nucleosynthesis, models of stellar and Galactic evolution, and H ii region physics. We discuss observations of radio recombination lines using the Green Bank Telescope toward a small sample of H ii regions and planetary nebulae. We report 4He/H abundance ratio differences as high as 15-20% between optical and ratio data that are difficult to reconcile. Using the H ii regions S206 and M17 we determine 4He production in the Galaxy to be dY/dZ = 1.71 ± 0.86.

  18. Administering Spatial and Cognitive Instruments In-class and On-line: Are These Equivalent?

    Science.gov (United States)

    Williamson, Kenneth C.; Williamson, Vickie M.; Hinze, Scott R.

    2017-02-01

    Standardized, well-established paper-and-pencil tests, which measure spatial abilities or which measure reasoning abilities, have long been found to be predictive of success in the STEM (science, technology, engineering, and mathematics) fields. Instructors can use these tests for prediction of success and to inform instruction. A comparative administration of spatial visualization and cognitive reasoning tests, between in-class (proctored paper and pencil) and on-line (unproctored Internet) ( N = 457), was used to investigate and to determine whether the differing instrument formats yielded equal measures of spatial ability and reasoning ability in large first-semester general chemistry sections. Although some gender differences were found, findings suggest that some differences across administration formats, but that on-line administration had similar properties of predicting chemistry performance as the in-class version. Therefore, on-line administration is a viable option for instructors to consider especially when dealing with large classes.

  19. On-line measurement of crystalline color by color-image processing system; Gazo shori system wo mochiita kessho no online iro sokutei

    Energy Technology Data Exchange (ETDEWEB)

    Okayasu, S.; Katayama, M.; Shinohara, T. [Ajinomoto Co. Inc., Tokyo (Japan)

    1996-01-20

    Aiming for the stable operation and the rationalization of factory plant, the color-image processing has been tried to introduce into the on-line system to measure the crystalline color of L-Lysine in its refining process. Because the practical spectro-photometry was used to be employed by manual measurement. In this paper, the calculation formula of the transmittance by spectrophotometry is theoretically introduced by analyzing the relation of Lambert-Beer`s law of luminous transparency with the Kubelka-Munk`s function of the luminous dispersion using color image data. The parameters of the calculation formula were decided by actual measurement, so that the formula with accuracy value of {plus_minus}3% elucidated the possible estimation of transmittance by spectrophotometry. The system was tested on a commercial plant, and some issues are discussed. 8 refs., 8 figs., 3 tabs.

  20. Study on the Extremely Low Frequency (ELF) Electromagnetic Field (EMF) emission from overhead High-Voltage Transmission Lines

    International Nuclear Information System (INIS)

    Parthasarathy, S.R.; Roha Tukimin; Wan Saffiey Wan Abdullah; Zulkifli Yusof; Mohd Azizi Mohd Jali

    2016-01-01

    The paper highlights the study on the Extremely Low Frequency (ELF) Electromagnetic Field (EMF) emission performed at an overhead 275-kV High-Voltage Transmission Lines. The study comprised of assessment at the transmission lines on 3 different cases and locations in Klang Valley, specifically on a vacant land near the transmission line, inside and around the house at the vicinity of the transmission line and the area directly under the transmission line. The instrument setup and measurement protocols during the assessment were adopted from standard measurement method and procedures stipulated under the Institute of Electrical and Electronics Engineers (IEEE) Standard. The results were compared with the standards recommended in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. The results showed that the measured field strengths are within the safety limit with the highest measured exposure was 10.8 % and 1.8 % of the permissible exposure limit for the electric and magnetic field respectively. Both the field strengths were found to drop significantly against distance from the transmission lines where closer distances showed higher field strengths. Furthermore, the study revealed that buildings and other object such as trees and shrubs screen out the electric field, resulting in a lower value at indoor measurements and near the stated objects. In addition, higher value of electric and magnetic field strengths were recorded when assessment was being done directly under the transmission line compared to the lateral measurement. (author)

  1. Resonant Alfven waves on auroral field lines

    International Nuclear Information System (INIS)

    Chiu, Y.T.

    1987-01-01

    It is shown that resonant Alfven waves on dipole magnetic field geometry and plasma distributions suitable for auroral field lines can be conveniently treated in the theory of Mathieu functions. Resurgent interest in invoking large-scale Alfven waves to structure some elements of auroral electrodynamics calls for interpretation of measured perpendicular electric and magnetic disturbance fields in terms of Alfven waves. The ability to express the resonant eigenmodes in closed form in terms of Mathieu functions allows for convenient tests of the Alfven wave structuring hypothesis. Implications for current vector electric and magnetic disturbance measurements are discussed

  2. The Effect of Error Correlation on Interfactor Correlation in Psychometric Measurement

    Science.gov (United States)

    Westfall, Peter H.; Henning, Kevin S. S.; Howell, Roy D.

    2012-01-01

    This article shows how interfactor correlation is affected by error correlations. Theoretical and practical justifications for error correlations are given, and a new equivalence class of models is presented to explain the relationship between interfactor correlation and error correlations. The class allows simple, parsimonious modeling of error…

  3. Perspectives for on-line analysis of bauxite by neutron irradiation

    Science.gov (United States)

    Beurton, Gabriel; Ledru, Bertrand; Letourneur, Philippe

    1995-03-01

    The interest in bauxite as a major source of alumina results in a strong demand for on-line instrumentation suitable for sorting, blending, and processing operations at the bauxite mine and for monitoring instrumentation in the Bayer process. The results of laboratory experiments based on neutron interactions with bauxite are described. The technique was chosen in order to overcome the problem of spatial heterogeneity in bulk mineral analysis. The evaluated elements contributed to approximately 99.5% of the sample weight. In addition, the measurements provide valuable information on physical parameters such as density, hygrometry, and material flow. Using a pulsed generator, the analysis system offers potential for on-line measurements (borehole logging or conveyor belt). An overall description of the experimental set-up is given. The experimental data include measurements of natural radioactivity, delayed radioactivity induced by activation, and prompt gamma rays following neutron reaction. In situ applications of neutron interactions provide continuous analysis and produce results which are more statistically significant. The key factors contributing to advances in industrial applications are the development of high count rate gamma spectroscopy and computational tools to design measurement systems and interpret their results.

  4. SOURCE TERM ESTIMATION BASED on PLANT STATUS and on GAMMA DOSE RATES Measured by an ON-line environmental Monitoring Network

    International Nuclear Information System (INIS)

    Stubna, M.; Bujan, A.; Duranova, T.

    1997-01-01

    A number of severe accident analyses for reactor unit with WWER-440 (213) has been performed in order to evaluate the source term and radiological consequences. As a tool for these analyses the WWER modified version of Source Term Code Package and Real Time Accident Release Consequences codes have been used. A set of emergency procedures - manuals for quick estimation of the source term and countermeasures introduction during early -pre-release phase of severe accident progression has been developed at Nuclear Power Plants Research Institute Trnava, Inc. These manuals are subdivided into three groups: 1.) evaluation of the barriers integrity, 2.) source term estimation and 3.) estimation of the distances for the countermeasures introduction. A methodology and computer module for interpretation of environmental data - source term assessment during post-release phase from on-line environmental network has been developed at Nuclear Power Plants Research Institute Trnava, Inc. The method is based on the conversion of measured dose rates to the source term,i.e. airborne radioactivity release rate, taking into account real meteorological data and location of the measure points. The bootstrap method for the estimation of the mean value of source term Q as integral value of the release and confidence interval of Q has been selected. The methodology of Q distribution into fission product groups according to code Real Time Accident Release Consequences needs is based on known plant status, i.e. on the results of pre calculated accident sequences. The paper describes the methodologies introduced above and the way of their application

  5. ELT-MELAS analyzer and its on-line programs

    International Nuclear Information System (INIS)

    Anikeev, V.B.; Berezhnoj, V.A.; Glupova

    1976-01-01

    ELT-MELAS device constructed for an automatic analysis of pictures from big bubble chambers is described. It is controlled by a medium-size ICL-1903A computer and has two measuring modes: analysis of the ''agreement'' signal and digitation of slice-scans. Main features of the hardware and of on-line controlling and diagnostic software are presented. The test results of the MELAS complex as well as preliminary results of the scan-slice measurements of pictures from 15sup(') chamber are given

  6. On-line system on the base of the ELEKTRONIKA D3-28 microcomputer for gas filling

    International Nuclear Information System (INIS)

    Artemov, A.A.; Baranchuk, N.S.; Livitskij, M.M.; Platonov, V.P.; Chernyak, V.Ya.

    1989-01-01

    On-line system for gas filling on the base of SNA-1 pressure controller, ELEKTRONIKA D3-28 microcomputer and interface device and program for information exchange within the system are described. The system is designed for on-line measurement of gas pressure and filling and is used during operation without pumping out. Volume of vacuum chamber is 0.8 m 3 , pressure of filled-out gas (nitrogen) is 1 atm. The system enables to change pressure up to 0.1 Torr with 1x10 -4 Torr accuracy. Actuation time of g as filling-on system is determined with program control and depends on pressure measurement. Minimal actuation time of gas filling-on system is determined with program control and depends on pressure measurement. Minimal actuation time is 12 ms

  7. On-line determination of moisture in coke on conveyor belts

    International Nuclear Information System (INIS)

    Millen, M.J.; Rafter, P.T.; Sowerby, B.D.

    1988-01-01

    A fast neutron and γ-ray transmission technique is being developed for the on-line determination of moisture in coke on conveyor belts. Calculations show that the technique is capable of determining coke moisture to within 0.3 wt% for coke thicknesses down to 50 mm provided that count rates are measured to within 0.1% relative. Laboratory measurements on static and moving coke samples showed that coke moisture can be determined to within 0.25 and 0.45 wt% for crushed and lump coke, respectively. It is planned to carry out a long-term plant trial of the technique on lump coke feed to the No. 3 blast furnace at BHP, Newcastle, NSW, Australia. (author)

  8. A phylogenetic analysis of the monogenomic Triticeae (Poaceae) based on morphology

    DEFF Research Database (Denmark)

    Seberg, Ole; Frederiksen, Signe Elisabeth

    2001-01-01

    not traditionally included in Aegilops s.J. Most of the 33 characters used in the analysis are coded as binary. The only four multistate characters in the matrix are treated as unordered. Three diploid species of Bromus are used as outgroup. The number of equally parsimonious trees found is very large (approx....... 170000; length = 107, ci = 0.36, ri = 0.75) and the strict consensus tree has an expectedly low level of resolution. However, most of the equally parsimonious trees owe their existence to an unresolved Aegilops clade. If this clade is replaced by its hypothetical ancestor, the number of equally...... parsimonious trees drops dramatically (48; length = 78, ci = 0.45, ri = 0.76). When trees for which more highly resolved compatible trees exist are excluded, only two trees remain. Bremer support is used as a measure of branch support. The trees based on morphology and on molecular data are largely incongruent....

  9. Fault Location Based on Synchronized Measurements: A Comprehensive Survey

    Science.gov (United States)

    Al-Mohammed, A. H.; Abido, M. A.

    2014-01-01

    This paper presents a comprehensive survey on transmission and distribution fault location algorithms that utilize synchronized measurements. Algorithms based on two-end synchronized measurements and fault location algorithms on three-terminal and multiterminal lines are reviewed. Series capacitors equipped with metal oxide varistors (MOVs), when set on a transmission line, create certain problems for line fault locators and, therefore, fault location on series-compensated lines is discussed. The paper reports the work carried out on adaptive fault location algorithms aiming at achieving better fault location accuracy. Work associated with fault location on power system networks, although limited, is also summarized. Additionally, the nonstandard high-frequency-related fault location techniques based on wavelet transform are discussed. Finally, the paper highlights the area for future research. PMID:24701191

  10. Fault Location Based on Synchronized Measurements: A Comprehensive Survey

    Directory of Open Access Journals (Sweden)

    A. H. Al-Mohammed

    2014-01-01

    Full Text Available This paper presents a comprehensive survey on transmission and distribution fault location algorithms that utilize synchronized measurements. Algorithms based on two-end synchronized measurements and fault location algorithms on three-terminal and multiterminal lines are reviewed. Series capacitors equipped with metal oxide varistors (MOVs, when set on a transmission line, create certain problems for line fault locators and, therefore, fault location on series-compensated lines is discussed. The paper reports the work carried out on adaptive fault location algorithms aiming at achieving better fault location accuracy. Work associated with fault location on power system networks, although limited, is also summarized. Additionally, the nonstandard high-frequency-related fault location techniques based on wavelet transform are discussed. Finally, the paper highlights the area for future research.

  11. On-line hyperfine structure and isotope shift measurements with diffuse light collection and photon burst detection

    International Nuclear Information System (INIS)

    Lassen, J.; Benck, E.C.; Schuessler, H.A.

    1997-01-01

    An experiment is presently being set up which combines collinear-fast-beam laser spectroscopy with photon burst spectroscopy. Selectivity is provided by the large kinetic isotope shifts together with the practically Doppler free linewidth of the fluorescence from the fast atom beam. The photon burst detection, based on photon correlations in the resonance fluorescence, increases the sensitivity, so that on-line optical isotope shift and hyperfine structure measurements on low intensity radioactive beams become feasible. In order to improve photon burst detection the solid angle of detection and the observation time have to be optimized. To this end a diffuse reflecting cavity has been designed and built, which collects fluorescence over a 45 cm length of the beam and covers the full solid angle. The light collection efficiency of the cavity is calculated to be about 45%. The cavity is being tested with a 11 keV beam of krypton atoms, probing the near infrared transitions in our apparatus at Texas A ampersand M University. copyright 1997 American Institute of Physics

  12. Dynamics of contact line depinning during droplet evaporation based on thermodynamics.

    Science.gov (United States)

    Yu, Dong In; Kwak, Ho Jae; Doh, Seung Woo; Ahn, Ho Seon; Park, Hyun Sun; Kiyofumi, Moriyama; Kim, Moo Hwan

    2015-02-17

    For several decades, evaporation phenomena have been intensively investigated for a broad range of applications. However, the dynamics of contact line depinning during droplet evaporation has only been inductively inferred on the basis of experimental data and remains unclear. This study focuses on the dynamics of contact line depinning during droplet evaporation based on thermodynamics. Considering the decrease in the Gibbs free energy of a system with different evaporation modes, a theoretical model was developed to estimate the receding contact angle during contact line depinning as a function of surface conditions. Comparison of experimentally measured and theoretically modeled receding contact angles indicated that the dynamics of contact line depinning during droplet evaporation was caused by the most favorable thermodynamic process encountered during constant contact radius (CCR mode) and constant contact angle (CCA mode) evaporation to rapidly reach an equilibrium state during droplet evaporation.

  13. Short-coherence in-line phase-shifting infrared digital holographic microscopy for measurement of internal structure in silicon

    Science.gov (United States)

    Xi, Teli; Dou, Jiazhen; Di, Jianglei; Li, Ying; Zhang, Jiwei; Ma, Chaojie; Zhao, Jianlin

    2017-06-01

    Short-coherence in-line phase-shifting digital holographic microscopy based on Michelson interferometer is proposed to measure internal structure in silicon. In the configuration, a short-coherence infrared laser is used as the light source in order to avoid the interference formed by the reference wave and the reflected wave from the front surface of specimen. At the same time, in-line phase-shifting configuration is introduced to overcome the problem of poor resolution and large pixel size of the infrared camera and improve the space bandwidth product of the system. A specimen with staircase structure is measured by using the proposed configuration and the 3D shape distribution are given to verify the effectiveness and accuracy of the method.

  14. Are our dynamic water quality models too complex? A comparison of a new parsimonious phosphorus model, SimplyP, and INCA-P

    Science.gov (United States)

    Jackson-Blake, L. A.; Sample, J. E.; Wade, A. J.; Helliwell, R. C.; Skeffington, R. A.

    2017-07-01

    Catchment-scale water quality models are increasingly popular tools for exploring the potential effects of land management, land use change and climate change on water quality. However, the dynamic, catchment-scale nutrient models in common usage are complex, with many uncertain parameters requiring calibration, limiting their usability and robustness. A key question is whether this complexity is justified. To explore this, we developed a parsimonious phosphorus model, SimplyP, incorporating a rainfall-runoff model and a biogeochemical model able to simulate daily streamflow, suspended sediment, and particulate and dissolved phosphorus dynamics. The model's complexity was compared to one popular nutrient model, INCA-P, and the performance of the two models was compared in a small rural catchment in northeast Scotland. For three land use classes, less than six SimplyP parameters must be determined through calibration, the rest may be based on measurements, while INCA-P has around 40 unmeasurable parameters. Despite substantially simpler process-representation, SimplyP performed comparably to INCA-P in both calibration and validation and produced similar long-term projections in response to changes in land management. Results support the hypothesis that INCA-P is overly complex for the study catchment. We hope our findings will help prompt wider model comparison exercises, as well as debate among the water quality modeling community as to whether today's models are fit for purpose. Simpler models such as SimplyP have the potential to be useful management and research tools, building blocks for future model development (prototype code is freely available), or benchmarks against which more complex models could be evaluated.

  15. ON THE APPARENT NARROWING OF RADIO RECOMBINATION LINES AT HIGH PRINCIPAL QUANTUM NUMBERS

    International Nuclear Information System (INIS)

    Alexander, J.; Gulyaev, S.

    2012-01-01

    We critically analyze the Bell et al. findings on 'anomalous' widths of high-order hydrogen radio recombination lines in the Orion Nebula at 6 GHz. We review their method of modified frequency switching and show that the way this method is used for large Δn is not optimal and can lead to misinterpretation of measured spectral line parameters. Using a model of the Orion Nebula, conventional broadening theory, and Monte Carlo simulation, we determine a transition zone n = 224, ..., 241 (Δn = 11, ..., 14), where measurement errors grow quickly with n and become comparable with the measurement values themselves. When system noise and spectrum channelization are accounted for, our simulation predicts 'processed' line narrowing in the transition zone similar to that reported by Bell et al. We find good agreement between our simulation results and their findings, both in line temperatures and widths. We conclude, therefore, that Bell et al.'s findings do not indicate a need to revise Stark broadening theory.

  16. Validation of the actuator line/Navier Stokes technique using mexico measurements

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Zhu, Wei Jun; Sørensen, Jens Nørkær

    2010-01-01

    This paper concerns the contribution of DTU MEK in the international research collaboration project (MexNext) within the framework of IEA Annex 29 to validate aerodynamic models or CFD codes using the existing measurements made in the previous EU funded projectMEXICO (Model Experiments in Control......This paper concerns the contribution of DTU MEK in the international research collaboration project (MexNext) within the framework of IEA Annex 29 to validate aerodynamic models or CFD codes using the existing measurements made in the previous EU funded projectMEXICO (Model Experiments...... in Controlled Conditions). The Actuator Line/Navier Stokes (AL/NS) technique developed at DTU is validated against the detailed MEXICO measurements. The AL/NS computations without the DNW wind tunnel with speeds of 10m/s, 15m/s and 24m/s. Comparisons of blade loading between computations and measurements show...

  17. Wavelength Measurements of Ni L-shell Lines between 9 and 15 A

    Science.gov (United States)

    Gu, Ming F.; Beiersdorfer, P.; Brown, G. V.; Chen, H.; Thorn, D. B.; Kahn, S. M.

    2006-09-01

    We present accurate wavelength measurements of nikel L-shell X-ray lines resulting from Δ n ≥ 1 transitions (mostly, 2 - 3 transitions) between 9 and 15 Å. We have used the electron beam ion trap, SuperEBIT, at the Lawrence Livermore National Laboratory and a flat field grating spectrometer to record the spectra. Most significant emission lines of Ni XIX -- XXVI in our spectral coverage are identified. The resulting data set provides valuable input in the analyses of high resolution X-ray spectra of stellar coronae sources, including the Sun. This work was performed under the auspices of U.S. DOE contract No. W-7405-Eng-48, and supported by NASA APRA Grant NAG5-5419.

  18. The on-line data acquisition system for the MHD facility of Frascati

    International Nuclear Information System (INIS)

    Di Bartolomeo, M.; Papalia, B.; Gay, P.; Panaccione, L.

    1975-01-01

    An on-line data acquisition system for the MHD facility of the Laboratorio Conversione Diretta at Frascati is described. After a brief description of the MHD facility and of the measurement requirements, the criteria a,d the configuration of the minicomputer-based data acquisition system chosen are presented. Then the general philosophy and the flow-charts of the software implemented are shown, with particular emphasis to the real-time requirements of the measurement system. At last it is illustrated an off-line program, running on a large computer, that elaborates the output data of the data acquisition system

  19. Direct measurement of the quantum state of the electromagnetic field in a superconducting transmission line

    International Nuclear Information System (INIS)

    Melo, F. de; Aolita, L.; Davidovich, L.; Toscano, F.

    2006-01-01

    We propose an experimental procedure to directly measure the state of an electromagnetic field inside a resonator, corresponding to a superconducting transmission line, coupled to a Cooper-pair box (CPB). The measurement protocol is based on the use of a dispersive interaction between the field and the CPB, and the coupling to an external classical field that is tuned to resonance with either the field or the CPB. We present a numerical simulation that demonstrates the feasibility of this protocol, which is within reach of present technology

  20. Wireless overhead line temperature sensor based on RF cavity resonance

    International Nuclear Information System (INIS)

    Ghafourian, Maryam; Nezhad, Abolghasem Zeidaabadi; Bridges, Greg E; Thomson, Douglas J

    2013-01-01

    The importance of maximizing power transfer through overhead transmission lines necessitates the use of dynamic power control to keep transmission line temperatures within acceptable limits. Excessive conductor operating temperatures lead to an increased sag of the transmission line conductor and may reduce their expected life. In this paper, a passive wireless sensor based on a resonant radio frequency (RF) cavity is presented which can be used to measure overhead transmission line temperature. The temperature sensor does not require a power supply and can be easily clamped to the power line with an antenna attached. Changing temperature causes a change of cavity dimensions and a shift in resonant frequency. The resonant frequency of the cavity can be interrogated wirelessly. This temperature sensor has a resolution of 0.07 °C and can be interrogated from distances greater than 4.5 m. The sensor has a deviation from linearity of less than 2 °C. (paper)

  1. Improvement in dose escalation using off-line and on-line image feedback in the intensity modulated beam design for prostate cancer treatment

    International Nuclear Information System (INIS)

    Yan, D.; Birkner, M.; Nuesslin, F.; Wong, J.; Martinez, A.

    2001-01-01

    Purpose: To test the capability of dose escalation in the IMRT process where the organ/patient temporal geometric variation, measured using either off-line or on-line treatment CT and portal images, are adapted for the optimal design of intensity modulated beam. Materials and Methods: Retrospective study was performed on five prostate cancer patients with multiple CT scans (14∼17/patient) and daily portal images obtained during the treatment course. These images were used to determine the displacements of each subvolume in the organs of interest caused by the daily patient setup and internal organ motion/deformation. The temporal geometric information was processed in order of treatment time and fed into an inverse planning system. The inverse planning engine was specifically implemented to adapt the design of intensity modulated beam to the temporal subvolume displacement and patient internal density changes. Three image feedback strategies were applied to each patient and evaluated with respect to the capability of safe dose escalation. The first one is off-line image feedback, which designs the beam intensity based on the patient images measured within the first week of treatment. The second is an on-line 'the target of the day' strategy, which designs the beam intensity in daily bases by using 'the image of the day' alone. The last one is also the on-line based. However, it designs the instantaneous beam intensity based on also dose distribution in each organ of interest received prior to the current treatment. For each of the treatment strategies, the minimum dose delivered to the CTV was determined by applying the identical normal tissue constraints of partial dose/volumes. This minimum dose was used to represent the treatment dose for each patient. Results: The off-line strategy appears feasible after 5 days of image feedback. The average treatment dose among the patients can be 10% higher than the one in the conventional IMRT treatment where the inverse

  2. Intensity and bunch length measurement for lepton beam in the injection lines of the SPS and LEP

    CERN Document Server

    Boccard, C; Papis, J P; Vos, L

    1995-01-01

    We describe a system which is used operationally to measure the absolute intensity of single lepton bunches in a beam transfer line. It is based on the detailed knowledge of every single item of a complex measuring chain that comprises a beam coupler on one end and an acquisition system on the other end. This knowledge can be acquired by a well tested theoretical model and careful measurement of the transfer function of each processing module. A precision better than 3 % can be obtained and no external calibration is required. A value for the bunch length can be deduced from a spectral intensity measurement at two well chosen frequencies.

  3. Transmission Line Ampacity Improvements of AltaLink Wind Plant Overhead Tie-Lines Using Weather-Based Dynamic Line Rating

    Energy Technology Data Exchange (ETDEWEB)

    Bhattarai, Bishnu P.; Gentle, Jake P.; Hill, Porter; McJunkin, Tim; Myers, Kurt S.; Abbound, Alex; Renwick, Rodger; Hengst, David

    2017-07-01

    Abstract—Overhead transmission lines (TLs) are conventionally given seasonal ratings based on conservative environmental assumptions. Such an approach often results in underutilization of the line ampacity as the worst conditions prevail only for a short period over a year/season. We presents dynamic line rating (DLR) as an enabling smart grid technology that adaptively computes ratings of TLs based on local weather conditions to utilize additional headroom of existing lines. In particular, general line ampacity state solver utilizes measured weather data for computing the real-time thermal rating of the TLs. The performance of the presented method is demonstrated from a field study of DLR technology implementation on four TL segments at AltaLink, Canada. The performance is evaluated and quantified by comparing the existing static and proposed dynamic line ratings, and the potential benefits of DLR for enhanced transmission assets utilization. For the given line segments, the proposed DLR results in real-time ratings above the seasonal static ratings for most of the time; up to 95.1% of the time, with a mean increase of 72% over static rating.

  4. Absolute orbit determination using line-of-sight vector measurements between formation flying spacecraft

    Science.gov (United States)

    Ou, Yangwei; Zhang, Hongbo; Li, Bin

    2018-04-01

    The purpose of this paper is to show that absolute orbit determination can be achieved based on spacecraft formation. The relative position vectors expressed in the inertial frame are used as measurements. In this scheme, the optical camera is applied to measure the relative line-of-sight (LOS) angles, i.e., the azimuth and elevation. The LIDAR (Light radio Detecting And Ranging) or radar is used to measure the range and we assume that high-accuracy inertial attitude is available. When more deputies are included in the formation, the formation configuration is optimized from the perspective of the Fisher information theory. Considering the limitation on the field of view (FOV) of cameras, the visibility of spacecraft and the installation of cameras are investigated. In simulations, an extended Kalman filter (EKF) is used to estimate the position and velocity. The results show that the navigation accuracy can be enhanced by using more deputies and the installation of cameras significantly affects the navigation performance.

  5. On-line slurry viscosity and concentration measurement as a real-time waste stream characterization tool. 1998 annual progress report

    International Nuclear Information System (INIS)

    Powell, R.L.

    1998-01-01

    'This project seeks to develop an on-line sensor to measure the viscosity of dense slurries. This report summarizes work after two years of a three year project. The flow behavior of slurries is important for many of the proposed unit operations to be used in the conveying and processing of tank wastes. One alternative for determining the rheological properties of such materials is to obtain samples and test them off-line using conventional rheometers. Such a protocol is not practical for a wide variety of wastes. Rather, it is the goal of this work to find on-line, in-process techniques for measurement. There are two systems that the authors have propose examining: (1) Nuclear magnetic resonance imaging (NMRI), and, (2) Ultrasonic Doppler Velocimetry. Central to both of these techniques is the measurement of velocity profiles in pipe flows. For the NMRI measurements, the presence of particles has two principal effects on the NMRI velocity profiles: a decrease in signal intensity and image blurring. Similar effects are observed in turbulent flows due to the local random fluctuations in the flow. This similarity has led us to turbulent flow using NMRI. The governing equations for the signal obtained by NMRI are the Bloch-Torrey equations. Previously, the author showed a relationship between turbulent fluctuations and spatial signal intensity variations, assuming isotropic turbulence. However, this assumption does not reflect the true nature of turbulence in a pipe flow where the turbulence is not isotropic. In the new work the Bloch-Torrey equations will be solved by first, time averaging and then employing a turbulence model for pipe flow. The purpose of the time averaging is to smooth the fluctuations of time scale smaller than that of NMRI data acquisition. After this work with single phase fluids, the authors shall undertake NMRI experiments of slurry flow. Various operational parameters will be optimized during the experiments to obtain velocity profile of the

  6. State Estimation-based Transmission line parameter identification

    Directory of Open Access Journals (Sweden)

    Fredy Andrés Olarte Dussán

    2010-01-01

    Full Text Available This article presents two state-estimation-based algorithms for identifying transmission line parameters. The identification technique used simultaneous state-parameter estimation on an artificial power system composed of several copies of the same transmission line, using measurements at different points in time. The first algorithm used active and reactive power measurements at both ends of the line. The second method used synchronised phasor voltage and current measurements at both ends. The algorithms were tested in simulated conditions on the 30-node IEEE test system. All line parameters for this system were estimated with errors below 1%.

  7. A Parsimonious Model of the Rabbit Action Potential Elucidates the Minimal Physiological Requirements for Alternans and Spiral Wave Breakup.

    Science.gov (United States)

    Gray, Richard A; Pathmanathan, Pras

    2016-10-01

    Elucidating the underlying mechanisms of fatal cardiac arrhythmias requires a tight integration of electrophysiological experiments, models, and theory. Existing models of transmembrane action potential (AP) are complex (resulting in over parameterization) and varied (leading to dissimilar predictions). Thus, simpler models are needed to elucidate the "minimal physiological requirements" to reproduce significant observable phenomena using as few parameters as possible. Moreover, models have been derived from experimental studies from a variety of species under a range of environmental conditions (for example, all existing rabbit AP models incorporate a formulation of the rapid sodium current, INa, based on 30 year old data from chick embryo cell aggregates). Here we develop a simple "parsimonious" rabbit AP model that is mathematically identifiable (i.e., not over parameterized) by combining a novel Hodgkin-Huxley formulation of INa with a phenomenological model of repolarization similar to the voltage dependent, time-independent rectifying outward potassium current (IK). The model was calibrated using the following experimental data sets measured from the same species (rabbit) under physiological conditions: dynamic current-voltage (I-V) relationships during the AP upstroke; rapid recovery of AP excitability during the relative refractory period; and steady-state INa inactivation via voltage clamp. Simulations reproduced several important "emergent" phenomena including cellular alternans at rates > 250 bpm as observed in rabbit myocytes, reentrant spiral waves as observed on the surface of the rabbit heart, and spiral wave breakup. Model variants were studied which elucidated the minimal requirements for alternans and spiral wave break up, namely the kinetics of INa inactivation and the non-linear rectification of IK.The simplicity of the model, and the fact that its parameters have physiological meaning, make it ideal for engendering generalizable mechanistic

  8. A Two-Line Absorption Instrument for Scramjet Temperature and Water Vapor Concentration Measurement in HYPULSE

    Science.gov (United States)

    Tsai, C. Y.

    1998-01-01

    A three beam water vapor sensor system has been modified to provide for near simultaneous temperature measurement. The system employs a tunable diode laser to scan spectral line of water vapor. The application to measurements in a scramjet combustor environment of a shock tunnel facility is discussed. This report presents and discusses die initial calibration of the measurement system.

  9. Improving the performance of a filling line based on simulation

    Science.gov (United States)

    Jasiulewicz-Kaczmarek, M.; Bartkowiak, T.

    2016-08-01

    The paper describes the method of improving performance of a filling line based on simulation. This study concerns a production line that is located in a manufacturing centre of a FMCG company. A discrete event simulation model was built using data provided by maintenance data acquisition system. Two types of failures were identified in the system and were approximated using continuous statistical distributions. The model was validated taking into consideration line performance measures. A brief Pareto analysis of line failures was conducted to identify potential areas of improvement. Two improvements scenarios were proposed and tested via simulation. The outcome of the simulations were the bases of financial analysis. NPV and ROI values were calculated taking into account depreciation, profits, losses, current CIT rate and inflation. A validated simulation model can be a useful tool in maintenance decision-making process.

  10. On Line Characterization of SiC Nanoparticles Produced by Laser Pyrolysis

    International Nuclear Information System (INIS)

    Wattieaux, G; Lecerf, P; Meyer, L; Boufendi, L; Leconte, Y; Sublemontier, O; Herlin, N; Asimakopoulou, A; Tsakis, A; Daskalos, M; Konstandopoulos, A G; Ouf, F X

    2011-01-01

    On Line Measurements campaigns have been carried out for the first time in IRAMIS/SPAM CEA's laser gas-phase pyrolysis nanoparticles production facilities. The produced aerosol is composed of Argon and/or Helium laden with SiC nanoparticles concentrated up to ∼14 mg/l. Different commercial apparatus were used for sampling, and characterisation of size, and morphology of the particles. A series of experiment is performed by IRSN with a DMS500 from Cambustion Ltd TM , which gives electrical mobility equivalent diameter distribution in real time. Particles are sampled with an ejector-diluter VKL-10 from Palas TM . On the same sampling line, APTL performed aerodynamic equivalent diameter mass distribution using a Nanomoudi from MSP Corp. TM and TEM post analysis, as well as post elemental analysis (EDS) after collection on TEM grid with a Thermophoretic Precipitator (TP). A previously developed model is used to obtain the aggregate morphology and primary particles sizes. In addition to these commercial or well-known techniques, a new patent-pending technique called RFPM (Radio Frequency Plasma Metrology developed by CILAS + GREMI in the frame of NANOCARA program) is tested for the first time off the lab. The principle is based on levitation of particles in plasma RF. The entire set up is a prototype, including the sampling line. Experiments showed that this technique is very promising for on line gas phase monitoring, even though future improvements are needed, especially on the direct injection of the sample in the measuring chamber. First results of size distribution on pyrolysis line were obtained: three modes of different geometric mean diameter D50 were measured. Further analysis of TEM micrographs gave insight on these three modes, they can be interpreted as primary particles, aggregated particles, and a third one which could be composed of silica oxide nanoparticles issued from the combustion of the remaining silane initiated by an air leak in the exhaust of

  11. Automated measurement of bolometer line of sight alignment and characteristics for application in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Penzel, Florian Olivier

    2015-07-01

    The line of sight (LOS) alignment and characteristic of a bolometer camera used in a fusion experiment is a crucial parameter for the measurement accuracy of the diagnostic. A robot based LOS measurement device has been developed which allows the fully automatic measurement of the two dimensional transmission function of a bolometer camera. It has been used to optimize camera prototypes for ITER and has been successfully operated in the fusion experiment ASDEX Upgrade in order to measure the LOS alignment.

  12. Applying TPM on Production Line of Huanwei

    Directory of Open Access Journals (Sweden)

    Zhai Yunkai

    2017-01-01

    The study based on the study and analysis of the TPM theory, based on my practice in the SMT2 production line of Victoria Electronics of Huanwei. Then it studied the promotion and implementation steps of TPM on SMT2 line. And it also introduced the improvement instance of SMT2 line. By contrasting the utilization of equipment on SMT2 line before and after the comprehensive of TPM, the necessity of implementing TPM is derived. For how to apply TPM on the production lines, and how to improve equipment comprehensive utilization, finish the order on time, provide high quality products to our customers, these are the main part of production line equipment management work. This article provides the reference for how to promote TPM on other production lines.

  13. On-line mass spectrometry system for measurements at single-crystal electrodes in hanging meniscus configuration

    NARCIS (Netherlands)

    Wonders, A.H.; Housmans, T.H.M.; Rosca, V.; Koper, M.T.M.

    2006-01-01

    We present the construction and some first applications of an On-line electrochemical mass spectrometry system for detecting volatile products formed during electrochemical reactions at a single-crystal electrode in hanging meniscus configuration. The system is based on a small inlet tip made of

  14. Measurement of transition probabilities in Kr II UV and visible spectral lines

    International Nuclear Information System (INIS)

    Mar, S; Val, J A del; RodrIguez, F; Pelaez, R J; Gonzalez, V R; Gonzalo, A B; Castro, A de; Aparicio, J A

    2006-01-01

    This work reports an extensive collection of 120 atomic transition probabilities of Kr II lines in the spectral region 350-720 nm, all of them measured in an emission experiment. For many of them, these are the first data up to the authors' knowledge. Relative intensity measurements have been obtained on a pulsed discharge lamp and the absolute A ki -values have been calculated by considering the available data from the literature as reference for the plasma temperature diagnosis. Excitation temperature (14 000-28 000 K) has been determined by using the Boltzmann-plot method. The plasma electron density (0.2-0.8 x 10 23 m -3 ) has been determined by two-wavelength interferometry. This work extends a previous one already published by our laboratory [1, 2]. Comparisons have also been made with previous literature values

  15. Human interface for personal information systems. On-line handwriting recognition; Pasonaru joho kiki ni okeru human interface. On-line tegaki ninshiki

    Energy Technology Data Exchange (ETDEWEB)

    Morita, T. [Sharp Corp., Osaka (Japan)

    1996-01-05

    Most of information devices used in the business field use keyboards for the inputting measure, but keyboards are rather awkward for personal use. In contrast to this, the pen input method which everybody can use easily is a product of the latest development. In this articles, on-line handwritten letter recognition is roughly explained which is the basic technique of pen input. Pen input has a demerit that its letter inputting speed is slow, but has much more merits that Chinese ideographs can be directly input, figures, handwritten memoranda, etc. are treated likewise, the device itself can be made compact and no noise is made. The on-line letter recognition methods now used practically can be roughly divided into the pattern matching method and the basic stroke method. Each of them has its own merits and demerits. For the current on-line handwritten letter recognition, the condition is necessary to handwritten a letter in the square style (kaisho) and carefully within the framework for letter entry upon writing, and for this arrangement, input is performed through the work processes of pretreatment/feature extraction, stroke recognition, letter comparison, detail discrimination, and after-treatment. 3 refs., 7 figs.

  16. Measurement of the vacuum decay rate of orthopositronium formed in an MgO-lined cavity

    International Nuclear Information System (INIS)

    Gidley, D.W.; Zitzewitz, P.W.

    1978-01-01

    Orthopositronium decay rates are measured in MgO-lined cavities with various volumes and entrance apertures. Systematic effects of the entrance aperture, cavity geometry, and collisional pick-off are measured. The vacuum decay rate is determined to be 7.050+-0.013 μs -1 . (Auth.)

  17. Impact of Measurement Error on Synchrophasor Applications

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yilu [Univ. of Tennessee, Knoxville, TN (United States); Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gracia, Jose R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ewing, Paul D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Zhao, Jiecheng [Univ. of Tennessee, Knoxville, TN (United States); Tan, Jin [Univ. of Tennessee, Knoxville, TN (United States); Wu, Ling [Univ. of Tennessee, Knoxville, TN (United States); Zhan, Lingwei [Univ. of Tennessee, Knoxville, TN (United States)

    2015-07-01

    Phasor measurement units (PMUs), a type of synchrophasor, are powerful diagnostic tools that can help avert catastrophic failures in the power grid. Because of this, PMU measurement errors are particularly worrisome. This report examines the internal and external factors contributing to PMU phase angle and frequency measurement errors and gives a reasonable explanation for them. It also analyzes the impact of those measurement errors on several synchrophasor applications: event location detection, oscillation detection, islanding detection, and dynamic line rating. The primary finding is that dynamic line rating is more likely to be influenced by measurement error. Other findings include the possibility of reporting nonoscillatory activity as an oscillation as the result of error, failing to detect oscillations submerged by error, and the unlikely impact of error on event location and islanding detection.

  18. Research progress of on-line automatic monitoring of chemical oxygen demand (COD) of water

    Science.gov (United States)

    Cai, Youfa; Fu, Xing; Gao, Xiaolu; Li, Lianyin

    2018-02-01

    With the increasingly stricter control of pollutant emission in China, the on-line automatic monitoring of water quality is particularly urgent. The chemical oxygen demand (COD) is a comprehensive index to measure the contamination caused by organic matters, and thus it is taken as one important index of energy-saving and emission reduction in China’s “Twelve-Five” program. So far, the COD on-line automatic monitoring instrument has played an important role in the field of sewage monitoring. This paper reviews the existing methods to achieve on-line automatic monitoring of COD, and on the basis, points out the future trend of the COD on-line automatic monitoring instruments.

  19. Single-phased Fault Location on Transmission Lines Using Unsynchronized Voltages

    Directory of Open Access Journals (Sweden)

    ISTRATE, M.

    2009-10-01

    Full Text Available The increased accuracy into the fault's detection and location makes it easier for maintenance, this being the reason to develop new possibilities for a precise estimation of the fault location. In the field literature, many methods for fault location using voltages and currents measurements at one or both terminals of power grids' lines are presented. The double-end synchronized data algorithms are very precise, but the current transformers can limit the accuracy of these estimations. The paper presents an algorithm to estimate the location of the single-phased faults which uses only voltage measurements at both terminals of the transmission lines by eliminating the error due to current transformers and without introducing the restriction of perfect data synchronization. In such conditions, the algorithm can be used with the actual equipment of the most power grids, the installation of phasor measurement units with GPS system synchronized timer not being compulsory. Only the positive sequence of line parameters and sources are used, thus, eliminating the incertitude in zero sequence parameter estimation. The algorithm is tested using the results of EMTP-ATP simulations, after the validation of the ATP models on the basis of registered results in a real power grid.

  20. The Influence of Physical Fatigue on Work on a Production Line

    Directory of Open Access Journals (Sweden)

    Kołodziej Sabina

    2017-09-01

    Full Text Available The purpose of this study is to determine the factors having impacts on the physical fatigue of employees and to analyse its influence on work on a production line. In order to carry out these objectives, a comprehensive research was conducted in a medium enterprise producing processed fruit and vegetable products. Air temperature and humidity tests, employee survey, production line productivity measurements, and other observations were performed. Large variations in temperature and humidity were observed during the analysed period. Analysing the survey results, attention was paid to the declared length of sleeping of employees after each shift, the time when they feel fatigue and the factors that, according to respondents, have the greatest impact on the work performed. Attempts were made to determine the wellbeing of employees and to indicate the disturbing symptoms. Special attention was paid to the negative phenomena felt by respondents. The main factors affecting the physical fatigue of employees were identified and described. We sought to explain the impacts of physical fatigue on work on the production line. Improvements, which should help to reduce fatigue and improve working conditions, have been proposed. The analysis provided interesting information that could be used in various food manufacturing companies.

  1. Influence of visualization on consumption during on-line shopping

    OpenAIRE

    Hictaler, Urška

    2013-01-01

    This diploma work studies the influence of visualization on consumption during on-line shopping. The first part of the thesis starts with key areas of visualization, consumption and on-line shopping. Visualization, areas of use, human perception and ways of product presentation in on-line shops are defined discussed first. Next, consumption, consumers and factors that influence their decisions and satisfaction are defined. The last topic in the first part of the thesis discusses on-line shopp...

  2. Using meteorological forecasts in on-line predictions of wind power

    DEFF Research Database (Denmark)

    Nielsen, Torben Skov; Nielsen, Henrik Aalborg; Madsen, Henrik

    1999-01-01

    This report describes a model investigation into wind power prediction model as well as a tool for predicting the power production from wind turbines in an area - the Wind Power Prediction Tool (WPPT). The predictions are based on on-line measurements of power production for a selected set...

  3. Measurement of collisional self broadening of atomic resonance lines in selective reflection experiment

    International Nuclear Information System (INIS)

    Papoyan, A.V.

    1998-01-01

    A method is developed to measure directly the collisional self broadening rate for a dense atomic vapor from selective reflection spectra. Experimental realization for the atomic D 1 and D 2 resonance lines of Rb confirms a validity of the proposed technique. The deflection of experimentally measured values is not more than 20% from theoretically predicted ones in the atomic number density range of 7· 10 16 - 7· 10 17 cm - 3 . 10 refs

  4. Variations of the Hβ-emission line during a large flare on UV Ceti

    International Nuclear Information System (INIS)

    Moffett, T.J.; Evans, D.S.; Ferland, G.

    1977-01-01

    Simultaneous high-speed photometry and photoelectric scanner observations of the Hβ-line were obtained for five flare events, one a major flare, on UV Ceti on 1975 January 6. The relative increase in the intensity of the Hβ-line during the large flare was much greater than the relative continuum rise as measured both by the scanner and by broad-band photometric observations. In Hβ the flare lasted nearly 30 times as long as in the continuum. Peak intensity in the Hβ-line occurred later than the continuum maximum. The possibility of using emission line observations to detect flare activity on early spectral-type stars (dK - dG) is discussed. Some speculations on the mechanism of flare production are indulged. (author)

  5. Validation of the actuator line and disc techniques using the New MEXICO measurements

    DEFF Research Database (Denmark)

    Sarmast, Sasan; Shen, Wen Z.; Zhu, Wei Jun

    2016-01-01

    Actuator line and disc techniques are employed to analyse the wake obtained in the New MEXICO wind turbine experiment. The New MEXICO measurement campaign done in 2014 is a follow-up to the MEXICO campaign, which was completed in 2006. Three flow configurations in axial flow condition are simulated...

  6. The effects of lightning and high altitude electromagnetic pulse on power distribution lines

    Energy Technology Data Exchange (ETDEWEB)

    Uman, M.A.; Rubinstein, M.; Yacoub, Z. [Florida Univ., Gainesville, FL (United States)

    1995-01-01

    We simultaneously recorded the voltages induced by lightning on both ends of an unenergized 448-meter long unenergized electric power line and the lightning vertical electric and horizontal magnetic fields at ground level near the line. The lightning data studied and presented here were due both to cloud lightning and to very close (about 20 m from the line) artificially initiated lightning. For cloud sources, a frequency-domain computer program called EMPLIN was used to calculate induced line voltages as a function of source elevation, angle of incidence, and wave polarization of the radiated cloud discharge pulses in order to compare with the measurements. For very-close lightning, the measured line voltages could be grouped into two categories, those in which multiple, similarly shaped, evenly spaced pulses were observed, which we call oscillatory, and those dominated by a principal pulse with subsidiary oscillations of much smaller amplitude, which we call impulsive. The amplitude of the induced voltage ranged from tens of kilovolts for oscillatory voltages to hundreds of kilovolts for impulsive voltages. A new technique is derived for the calculation of the electromagnetic fields from nearby lightning to ground above an imperfectly conducting ground. This technique was used in conjunction with an existing time domain coupling theory and lightning return stroke model to calculate voltages at either end of the line. The results show fair agreement with the measured oscillatory voltage waveforms if corona is ignored and improved results when corona effects are modeled. The modeling of the impulsive voltage, for which local flashover probably successful. In an attempt to understand better the sources of the line voltages for very close lightning, measurements of the horizontal and vertical electric fields 30 m from triggered lightning were obtained.

  7. Contact wire positions and contact forces. Measurements at high-speed lines in China; Fahrdrahtlage und Kontaktkraefte. Messungen an Hochgeschwindigkeitsstrecken in China

    Energy Technology Data Exchange (ETDEWEB)

    Heland, Joerg; Rick, Frank; Sarnes, Bernhard [DB Systemtechnik GmbH, Muenchen (Germany); Puschmann, Rainer [Siemens AG, Erlangen (Germany). Infrastructure and Cities

    2012-07-15

    The reliable energy transmission from overhead contact line to pantograph of traction units without interruption decides on the successful operation of high-speed railway lines. Measurements of contact wire position and contact forces are suited to assess interaction of overhead contact line and pantograph. Chinese Railways actually implement the biggest electrification program for high-speed lines worldwide. For these projects contact wire position and contact forces are monitored by procedures developed in Germany. The experience confirms that keeping the contact wire position within the specified limits lead to a superior energy transmission up to 350 km/h. (orig.)

  8. Where and why hyporheic exchange is important: Inferences from a parsimonious, physically-based river network model

    Science.gov (United States)

    Gomez-Velez, J. D.; Harvey, J. W.

    2014-12-01

    Hyporheic exchange has been hypothesized to have basin-scale consequences; however, predictions throughout river networks are limited by available geomorphic and hydrogeologic data as well as models that can analyze and aggregate hyporheic exchange flows across large spatial scales. We developed a parsimonious but physically-based model of hyporheic flow for application in large river basins: Networks with EXchange and Subsurface Storage (NEXSS). At the core of NEXSS is a characterization of the channel geometry, geomorphic features, and related hydraulic drivers based on scaling equations from the literature and readily accessible information such as river discharge, bankfull width, median grain size, sinuosity, channel slope, and regional groundwater gradients. Multi-scale hyporheic flow is computed based on combining simple but powerful analytical and numerical expressions that have been previously published. We applied NEXSS across a broad range of geomorphic diversity in river reaches and synthetic river networks. NEXSS demonstrates that vertical exchange beneath submerged bedforms dominates hyporheic fluxes and turnover rates along the river corridor. Moreover, the hyporheic zone's potential for biogeochemical transformations is comparable across stream orders, but the abundance of lower-order channels results in a considerably higher cumulative effect for low-order streams. Thus, vertical exchange beneath submerged bedforms has more potential for biogeochemical transformations than lateral exchange beneath banks, although lateral exchange through meanders may be important in large rivers. These results have implications for predicting outcomes of river and basin management practices.

  9. New method of noncontact temperature measurement in on-line textile production

    Science.gov (United States)

    Cheng, Xianping; Song, Xing-Li; Deng, Xing-Zhong

    1993-09-01

    Based on the condition of textile production the method of infrared non-contact temperature measurement is adcpted in the heat-setting and drying heat-treatment process . This method is used to monitor the moving cloth. The temperature of the cloth is displayed rapidly and exactly. The principle of the temperature measurement is analysed theoretically in this paper. Mathematical analysis and calculation are used for introducing signal transmitting method. Adopted method of combining software with hardware the temperature is corrected and compensated with the aid of a single-chip microcomputer. The results of test indicate that the application of temperature measurement instrument provides reliable parameters in the quality control. And it is an important measure on improving the quality of products.

  10. Final report on fiscal year 1992 activities for the environmental monitors line-loss study

    International Nuclear Information System (INIS)

    Kenoyer, J.L.

    1993-01-01

    The work performed on this Environmental Monitors Line-Loss Study has been performed under Contract Numbers MLW-SVV-073750 and MFH-SVV-207554. Work on the task was initiated mid-December 1991, and this report documents and summarizes the work performed through January 18, 1993. The sections included in this report summarize the work performed on the Environmental Monitors Line-Loss Study. The sections included in this report are arranged to reflect individual sub-tasks and include: descriptions of measurement systems and procedures used to obtain cascade impactor samples and laser spectrometer measurements from multiple stacks and locations; information on data acquisition, analyses, assessment, and software; discussion of the analyses and measurement results from the cascade impactor and laser spectrometer systems and software used; discussion on the development of general test methods and procedures for line-loss determinations; an overall summary and specific conclusions that can be made with regard to efforts performed on this task during FY 1992 and FY 1993. Supporting information for these sections is included in this report as appendices

  11. Rock mass and shaft concrete lining temperature measurement procedure: Final draft

    International Nuclear Information System (INIS)

    1986-10-01

    This procedure document describes the equipment and procedures which will be used to obtain temperature data from within rock-mass and shaft linings at the Deaf Smith Exploratory Shaft Facility. Temperature measurement methods for instrument temperature correction, fluid temperature correction, heated surface monitoring and air temperature monitoring are outside the scope of this procedure, and are covered in the appropriate individual test procedures. Calibration, acceptance testing and the assignment of transducer reference numbers are outside the scope of this procedure. Section 2.0 provides a summary of the temperature measurement methods which will be employed, together with the measurement locations, environmental considerations and measurement requirements. Test layouts, including detailed descriptions of instruments, support requirements and detailed installation procedures are also presented. Section 3.0 describes the requirements for data recording, ADAS monitoring, and data reporting. Section 4.0 defines personnel responsibilities and qualifications. In addition a measurement and installation schedule is provided, and safety and contingency plans are described. Section 5.0 discusses management and quality assurance requirements. Cited references are listed in Section 6.0. 7 refs., 9 figs

  12. The Automated Threaded Fastening Based on On-line Identification

    Directory of Open Access Journals (Sweden)

    Nicolas Ivan Giannoccaro

    2008-11-01

    Full Text Available The principle of the thread fastenings have been known and used for decades with the purpose of joining one component to another. Threaded fastenings are popular because they permit easy disassembly for maintenance, repair, relocation and recycling. Screw insertions are typically carried out manually. It is a difficult problem to automat. As a result there is very little published research on automating threaded fastenings, and most research on automated assembly focus on the peg-in-hole assembly problem. This paper investigates the problem of automated monitoring of the screw insertion process. The monitoring problem deals with predicting integrity of a threaded insertion, based on the torque vs. insertion depth curve generated during the insertions. The authors have developed an analytical model to predict the torque signature signals during self-tapping screw insertions. However, the model requires parameters on the screw dimensions and plate material properties are difficult to measure. This paper presents a study on on-line identification during screw fastenings. An identification methodology for two unknown parameter estimation during a self-tapping screw insertion process is presented. It is shown that friction and screw properties required by the model can be reliably estimated on-line. Experimental results are presented to validate the identification procedure.

  13. Online measuring devices at sewage treatment plants - state of the art and future market potential; On-Line-Messtechnik auf Klaeranlagen - Aktueller Stand und Marktpotential fuer die Zukunft

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, P [Inst. fuer Siedlungswasserbau, Wasserguete- und Abfallwirtschaft der Univ. Stuttgart, Abt. Abwassertechnik (Germany); Schlegel, S [Emschergenossenschaft, Essen (Germany)

    1998-12-31

    By means of a survey commissioned by ATV/GFA, the purposes of use and spheres of use as well as the operating experience with online measuring devices for the determination of ammonium, oxidized nitrogen compounds and orthophosphate were established and evaluated. In addition, data were acquired with the aid of other units for the continuous recording of chemical and physical parameters of sewage treatment. Finally, the future market potentials and development pospects of online measuring devices were evaluated. (orig.) [Deutsch] Anhand einer im Auftrag der ATV/GFA durchgefuehrten Umfrage wurden Einsatzzweck, Einsatzbereiche und Betriebserfahrungen von On-line-Messgeraeten zur Bestimmung von Ammonium, oxidierten Stickstoffverbindungen und Orthophosphat dargestellt und bewertet. Zusaetzlich wurden auch Daten von anderen Geraeteeinheiten zur kontinuierlichen Erfassung von chemischen und physikalischen Parametern bei der Abwasserreinigung erhoben. Anschliessend wurde das zukuenftige Marktpotential und die Entwicklungsmoeglichkeiten bei der On-line-Messtechnik bewertet. (orig.)

  14. Online measuring devices at sewage treatment plants - state of the art and future market potential; On-Line-Messtechnik auf Klaeranlagen - Aktueller Stand und Marktpotential fuer die Zukunft

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, P. [Inst. fuer Siedlungswasserbau, Wasserguete- und Abfallwirtschaft der Univ. Stuttgart, Abt. Abwassertechnik (Germany); Schlegel, S. [Emschergenossenschaft, Essen (Germany)

    1997-12-31

    By means of a survey commissioned by ATV/GFA, the purposes of use and spheres of use as well as the operating experience with online measuring devices for the determination of ammonium, oxidized nitrogen compounds and orthophosphate were established and evaluated. In addition, data were acquired with the aid of other units for the continuous recording of chemical and physical parameters of sewage treatment. Finally, the future market potentials and development pospects of online measuring devices were evaluated. (orig.) [Deutsch] Anhand einer im Auftrag der ATV/GFA durchgefuehrten Umfrage wurden Einsatzzweck, Einsatzbereiche und Betriebserfahrungen von On-line-Messgeraeten zur Bestimmung von Ammonium, oxidierten Stickstoffverbindungen und Orthophosphat dargestellt und bewertet. Zusaetzlich wurden auch Daten von anderen Geraeteeinheiten zur kontinuierlichen Erfassung von chemischen und physikalischen Parametern bei der Abwasserreinigung erhoben. Anschliessend wurde das zukuenftige Marktpotential und die Entwicklungsmoeglichkeiten bei der On-line-Messtechnik bewertet. (orig.)

  15. In-line bulk supersaturation measurement by electrical conductometry in KDP crystal growth from aqueous solution

    Science.gov (United States)

    Bordui, P. F.; Loiacono, G. M.

    1984-07-01

    A method is presented for in-line bulk supersaturation measurement in crystal growth from aqueous solution. The method is based on a computer-controlled concentration measurement exploiting an experimentally predetermined cross-correlation between the concentration, electrical conductivity, and temperature of the growth solution. The method was applied to Holden crystallization of potassium dihydrogen phosphate (KDP). An extensive conductivity-temperature-concentration data base was generated for this system over a temperature range of 31 to 41°C. The method yielded continous, automated bulk supersaturation output accurate to within ±0.05 g KDP100 g water (±0.15% relative supersaturation).

  16. INIS retrieval service, towards on-line

    International Nuclear Information System (INIS)

    Ebinuma, Yukio; Komatsubara, Yasutoshi

    1983-01-01

    Japan Atomic Energy Research Institute executes the retrieval service of INIS atomic energy information by batch system in cooperation with Genshiryoku Kozaikai. This service is very popular to the users in whole Japan, but the demand of on-line service has increased recently. Therefore, it was decided to begin the INIS on-line service from January, 1984, through the on-line information retrieval system of the Japan Information Center of Science and Technology. It is expected that when the operation will be started, the utilization of INIS atomic energy information in Japan will drastically increase. Also Japan Atomic Energy Research Institute has carried out the retrieval service by on-line system for those in the institute besides the batch system, accordingly, at this opportunity, the state of utilization of both systems and their distinction to use effectively, and the operation and the method of utilization of the on-line information retrieval system of JICST are explained. In the on-line system, the users are accessible to the data base themselves, and immediate information retrieval is possible, while in the batch system, the related information can be retrieved without fail, and the troublesome operation of equipment is not necessary. (Kako, I.)

  17. Measuring the complex permittivity tensor of uniaxial biological materials with coplanar waveguide transmission line

    Science.gov (United States)

    A simple and accurate technique is described for measuring the uniaxial permittivity tensor of biological materials with a coplanar waveguide transmission-line configuration. Permittivity tensor results are presented for several chicken and beef fresh meat samples at 2.45 GHz....

  18. A unified approach to stochastic integration on the real line

    DEFF Research Database (Denmark)

    Basse-O'Connor, Andreas; Graversen, Svend-Erik; Pedersen, Jan

    Stochastic integration on the predictable σ-field with respect to σ-finite L0-valued measures, also known as formal semimartingales, is studied. In particular, the triplet of such measures is introduced and used to characterize the set of integrable processes. Special attention is given to Lévy...... processes indexed by the real line. Surprisingly, many of the basic properties break down in this situation compared to the usual R+ case....

  19. Bias Correction and Random Error Characterization for the Assimilation of HRDI Line-of-Sight Wind Measurements

    Science.gov (United States)

    Tangborn, Andrew; Menard, Richard; Ortland, David; Einaudi, Franco (Technical Monitor)

    2001-01-01

    A new approach to the analysis of systematic and random observation errors is presented in which the error statistics are obtained using forecast data rather than observations from a different instrument type. The analysis is carried out at an intermediate retrieval level, instead of the more typical state variable space. This method is carried out on measurements made by the High Resolution Doppler Imager (HRDI) on board the Upper Atmosphere Research Satellite (UARS). HRDI, a limb sounder, is the only satellite instrument measuring winds in the stratosphere, and the only instrument of any kind making global wind measurements in the upper atmosphere. HRDI measures doppler shifts in the two different O2 absorption bands (alpha and B) and the retrieved products are tangent point Line-of-Sight wind component (level 2 retrieval) and UV winds (level 3 retrieval). This analysis is carried out on a level 1.9 retrieval, in which the contributions from different points along the line-of-sight have not been removed. Biases are calculated from O-F (observed minus forecast) LOS wind components and are separated into a measurement parameter space consisting of 16 different values. The bias dependence on these parameters (plus an altitude dependence) is used to create a bias correction scheme carried out on the level 1.9 retrieval. The random error component is analyzed by separating the gamma and B band observations and locating observation pairs where both bands are very nearly looking at the same location at the same time. It is shown that the two observation streams are uncorrelated and that this allows the forecast error variance to be estimated. The bias correction is found to cut the effective observation error variance in half.

  20. Mjollnir Rotational Line Scan Diagnostics.

    Science.gov (United States)

    1981-05-19

    using long cavity. M8 Removable Pellicle Beam Splitter for He-Ne Lineup Beam. Removed before HF or DF laser is turned on. 27 A 27 * A r of the chopper...three probe laser lines, however three lines were sequentially measured to verify the diagnostic equipment. Two of the three lines have been monitored

  1. New developments in velocity profile measurement and pipe wall wear monitoring for hydrotransport lines

    Energy Technology Data Exchange (ETDEWEB)

    O' Keefe, C.; Maron, R.J. [CiDRA Minerals Processing Inc., Wallingford, CT (United States); Fernald, M.; Bailey, T. [CiDRA Corporate Services, Wallingford, CT (United States); Van der Spek, A. [ZDOOR, Rotterdam (Netherlands)

    2009-07-01

    Sonar array flow measurement technology was initially developed a decade ago with the goal of non-invasively measuring multi-phase flows in the petroleum industry. The same technology was later adapted to the mineral processing industry where it has been rapidly adopted. The specific sensor technology, based on piezoelectric film sensors, provides unique measurement capabilities, including the ability to non-invasively measure localized strains in the walls of pipes. Combined with sonar array processing algorithms, an axial array of such sensors can measure flow velocities within a pipe. The sensors are useful for monitoring and managing slurry flow in horizontal pipes since they provide real-time velocity profiles measurement. The information is useful in determining the approach and onset of solid deposition on the bottom of the pipe. The sensors also provide a non-invasive measurement of pipe wear on slurry lines. Such measurements are currently made by hand-held portable ultrasonic thickness gages. The shortfalls associated with this manual method are overcome with a set of permanently or semi-permanently installed transducers clamped onto the outside of the pipe, where sensors measure the thickness of the pipe. This system and approach results in better repeatability and accuracy compared to manual methods. It also decreases inspection labor costs and pipe access requirements. It was concluded that the potential impact on personnel safety and environmental savings will be significant. 3 refs., 20 figs.

  2. Research for the Influence of Distribution Network Line Reclosing Current on Line Protection

    Directory of Open Access Journals (Sweden)

    Yu Kansheng

    2016-01-01

    Full Text Available According to the distribution network line structure and reclosing control strategy, the system simulation model of distribution network lines has established based on the real-time digital simulation RTDS. Based on this, distribution network switching impulse current characteristic has researched with different capacity, different distribution and different load power factor under the different voltage switching angles. The results of the study provide a scientific basis for distribution network line protection setting, in order to further lay the foundation for improvement the validity and reliability of distribution network line protection action.

  3. The in-line measurement of plant cell biomass using radio frequency impedance spectroscopy as a component of process analytical technology.

    Science.gov (United States)

    Holland, Tanja; Blessing, Daniel; Hellwig, Stephan; Sack, Markus

    2013-10-01

    Radio frequency impedance spectroscopy (RFIS) is a robust method for the determination of cell biomass during fermentation. RFIS allows non-invasive in-line monitoring of the passive electrical properties of cells in suspension and can distinguish between living and dead cells based on their distinct behavior in an applied radio frequency field. We used continuous in situ RFIS to monitor batch-cultivated plant suspension cell cultures in stirred-tank bioreactors and compared the in-line data to conventional off-line measurements. RFIS-based analysis was more rapid and more accurate than conventional biomass determination, and was sensitive to changes in cell viability. The higher resolution of the in-line measurement revealed subtle changes in cell growth which were not accessible using conventional methods. Thus, RFIS is well suited for correlating such changes with intracellular states and product accumulation, providing unique opportunities for employing systems biotechnology and process analytical technology approaches to increase product yield and quality. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Measurement of the central ion and electron temperature of tokamak plasmas from the x-ray line radiation of high-Z impurity ions

    International Nuclear Information System (INIS)

    Bitter, M.; von Goeler, S.; Goldman, M.; Hill, K.W.; Horton, R.; Roney, W.; Sauthoff, N.; Stodiek, W.

    1982-04-01

    This paper describes measurements of the central ion and electron temperature of tokamak plasmas from the observation of the 1s - 2p resonance lines, and the associated dielectronic (1s 2 nl - 1s2pnl, with n greater than or equal to 2) satellites, of helium-like iron (Fe XXV) and titanium (Ti XXI). The satellite to resonance line ratios are very sensitive to the electron temperature and are used as an electron temperature diagnostic. The ion temperature is deduced from the Doppler width of the 1s - 2p resonance lines. The measurements have been performed with high resolution Bragg crystal spectrometers on the PLT (Princeton Large Torus) and PDX (Poloidal Divertor Experiment) tokamaks. The details of the experimental arrangement and line evaluation are described, and the ion and electron temperature results are compared with those obtained from independent diagnostic techniques, such as the analysis of charge-exchange neutrals and measurements of the electron cyclotron radiation. The obtained experimental results permit a detailed comparison with theoretical predictions

  5. Internal electric-field-lines distribution in CdZnTe detectors measured using X-ray mapping

    International Nuclear Information System (INIS)

    Bolotnikov, A.E.; Camarda, G.S.; Cui, Y.; Hossain, A.; Yang, G.; Yao, H.W.; James, R.B.

    2009-01-01

    The ideal operation of CdZnTe devices entails having a uniformly distributed internal electric field. Such uniformity especially is critical for thick long-drift-length detectors, such as large-volume CPG and 3-D multi-pixel devices. Using a high-spatial resolution X-ray mapping technique, we investigated the distribution of the electric field in real devices. Our measurements demonstrate that in thin detectors, 1 cm, with a large aspect ratio (thickness-to-width ratio), we observed two effects: the electric field lines bending away from or towards the side surfaces, which we called, respectively, the focusing field-line distribution and the defocusing field-line distribution. In addition to these large-scale variations, the field-line distributions were locally perturbed by the presence of extended defects and residual strains existing inside the crystals. We present our data clearly demonstrating the non-uniformity of the internal electric field

  6. Terahertz spectroscopy applied to the measurement of strengths and self-broadening coefficients for high- J lines of OCS

    Science.gov (United States)

    Matton, S.; Rohart, F.; Bocquet, R.; Mouret, G.; Bigourd, D.; Cuisset, A.; Hindle, F.

    2006-10-01

    A spectrometer operating in the 100-2000 GHz range and allowing for absolute line strength measurements has been developed. The continuous wave terahertz radiation is generated by mixing two Ti:Sapphire laser beams in a vertically integrated low temperature grown GaAs (LTG-GaAs) photomixer. Pure rotational lines of 16O 12C 32S in the ground vibrational state have been considered for J values up to 90. Observed self-broadening parameters are in agreement with those deduced from infrared experiments. For the first time in the submillimeter range, absolute line strengths have been determined, allowing for a determination of the electric dipole moment in good agreement with the value previously obtained from Stark effect measurements.

  7. Frequency lock of a dye laser emission on iron atomic line top

    International Nuclear Information System (INIS)

    Durand, P.

    1995-03-01

    The aim of this thesis is to realize a frequency lock of a dye laser emission on iron atomic line top. To reach that goal, the author first presents the calculation of atomic vapour density by means of laser absorption ratio measure and studies the dye laser working. It is then necessary to find a device giving the required precision on the frequency of the absorption line choosen. It is obtained thanks to the atomic line reconstitution by optogalvanic effect which gives the reference. Besides, the author presents the necessity of a laser emission power regulation which is obtained thanks to a device including an acoustic and optic modulator. A reliable and accurate captor is choosen and adjusted testing various hollow cathode lamps. The method to obtain the frequency lock of laser emission on iron atomic line top is described. (TEC). 18 refs., 64 figs

  8. Response analysis on nonuniform transmission line

    Directory of Open Access Journals (Sweden)

    Cvetković Zlata

    2005-01-01

    Full Text Available Transients on a loss less exponential transmission line with a pure resistance load are presented in this paper. The approach is based on the two-port presentation of the transmission line. Using Picard-Carson's method the transmission line equations are solved. The relationship between source voltage and the load voltage in s-domain is derived. All the results are plotted using program package Mathematica 3.0.

  9. The development of an on-line gold analyser

    International Nuclear Information System (INIS)

    Robert, R.V.D.; Ormrod, G.T.W.

    1982-01-01

    An on-line analyser to monitor the gold in solutions from the carbon-in-pulp process is described. The automatic system is based on the delivery of filtered samples of the solutions to a distribution valve for measurement by flameless atomic-absorption spectrophotometry. The samples is introduced by the aerosol-deposition method. Operation of the analyser on a pilot plant and on a full-scale carbon-in-pulp plant has shown that the system is economically feasible and capable of providing a continuous indication of the efficiency of the extraction process

  10. Study of Opacity Effects on Emission Lines at EXTRAP T2R RFP

    Science.gov (United States)

    Stancalie, Viorica; Rachlew, Elisabeth

    We have investigated the influence of opacity on hydrogen (H-α and Ly-β) and Li-like oxygen emission lines from the EXTRAP T2R reversed field pinch. We used the Atomic Data Analysis System (AzDAS) based on the escape factor approximation for radiative transfer to calculate metastable and excited population densities via a collisional-radiative model. Population escape factor, emergent escape factor and modified line profiles are plotted vs. optical depth. The simulated emission line ratios in the density/temperature plane are in good agreement with experimental data for electron density and temperature measurements.

  11. On-line monitoring of methane in sewer air.

    Science.gov (United States)

    Liu, Yiwen; Sharma, Keshab R; Murthy, Sudhir; Johnson, Ian; Evans, Ted; Yuan, Zhiguo

    2014-10-16

    Methane is a highly potent greenhouse gas and contributes significantly to climate change. Recent studies have shown significant methane production in sewers. The studies conducted so far have relied on manual sampling followed by off-line laboratory-based chromatography analysis. These methods are labor-intensive when measuring methane emissions from a large number of sewers, and do not capture the dynamic variations in methane production. In this study, we investigated the suitability of infrared spectroscopy-based on-line methane sensors for measuring methane in humid and condensing sewer air. Two such sensors were comprehensively tested in the laboratory. Both sensors displayed high linearity (R(2) > 0.999), with a detection limit of 0.023% and 0.110% by volume, respectively. Both sensors were robust against ambient temperature variations in the range of 5 to 35°C. While one sensor was robust against humidity variations, the other was found to be significantly affected by humidity. However, the problem was solved by equipping the sensor with a heating unit to increase the sensor surface temperature to 35°C. Field studies at three sites confirmed the performance and accuracy of the sensors when applied to actual sewer conditions, and revealed substantial and highly dynamic methane concentrations in sewer air.

  12. Fourier transform measurements of water vapor line parameters in the 4200-6600 cm{sup -1} region

    Energy Technology Data Exchange (ETDEWEB)

    Jenouvrier, Alain [Groupe de Spectrometrie Moleculaire et Atmospherique, UMR CNRS 6089, UFR Sciences, Moulin de la Housse, B.P. 1039, 51067 Reims Cedex 2 (France)]. E-mail: alain.jenouvrier@univ-reims.fr; Daumont, Ludovic [Groupe de Spectrometrie Moleculaire et Atmospherique, UMR CNRS 6089, UFR Sciences, Moulin de la Housse, B.P. 1039, 51067 Reims Cedex 2 (France); Regalia-Jarlot, Laurence [Groupe de Spectrometrie Moleculaire et Atmospherique, UMR CNRS 6089, UFR Sciences, Moulin de la Housse, B.P. 1039, 51067 Reims Cedex 2 (France); Tyuterev, Vladimir G. [Groupe de Spectrometrie Moleculaire et Atmospherique, UMR CNRS 6089, UFR Sciences, Moulin de la Housse, B.P. 1039, 51067 Reims Cedex 2 (France); Carleer, Michel [Service de Chimie Quantique et de Photophysique, CP 160/09, Universite Libre de Bruxelles, 50 Av. F.D. Roosevelt, B-1050 Brussels (Belgium); Vandaele, Ann Carine [Institut d' Aeronomie Spatiale de Belgique, Av. Circulaire 3, B-1180 Brussels (Belgium); Mikhailenko, Semen [Laboratory of Theoretical Spectroscopy, Institute of Atmospheric Optics, Russian Academy of Sciences, 1, Av. Akademichesskii, 634055 Tomsk (Russian Federation); Fally, Sophie [Service de Chimie Quantique et de Photophysique, CP 160/09, Universite Libre de Bruxelles, 50 Av. F.D. Roosevelt, B-1050 Brussels (Belgium)

    2007-06-15

    New high-resolution water vapor absorption spectra were obtained at room temperature in the 4200-6600 cm{sup -1} spectral region by combining Fourier transform spectrometers (FTS) with single and multiple reflection cells. With absorption paths from 0.3 to 1800 m in pure and air diluted water vapor, accurate measurements of about 10400 lines in an intensity range from 10{sup -29} to 10{sup -19} cm/molecule have been performed. Positions, intensities, self- and air-broadening coefficients and air-induced shifts were determined for the H{sub 2} {sup 16}O, H{sub 2} {sup 17}O, H{sub 2} {sup 18}O and HDO isotopologues. The rovibrational assignment of the observed lines was performed with the use of global variational predictions and allowed the identification of several new energy levels. One major contribution of this work consists of the identification of 3280 new weak lines. A very close agreement between the new measured parameters and those listed in the database is reported as well as between the observations and the most recent variational calculations for the positions and the intensities. The present parameters provide an extended and homogeneous data set for water vapor, which is shown to significantly improve the databases for atmospheric applications, especially in the transmission windows on both sides of the band centered at 5400 cm{sup -1}.

  13. Experimental studies on coherent synchrotron radiaiton in the emittance exchange line at the Fermilab A0 Photoinjector

    International Nuclear Information System (INIS)

    Thangaraj, J.C.T.; Keup, R.; Johnson, A.; Ruan, J.; Piot, P.; Church, M.; Edwards, H.; Lumpkin, A.; Sun, Y.-E.; Santucci, J.

    2011-01-01

    Future accelerators will employ advanced beam conditioning systems such as emittance exchangers to manipulate high brightness beams. Coherent synchrotron radiation (CSR) in the dipoles could limit the performance of the emittance exchanger. In this paper, we report the experimental studies on measuring CSR and its effects on the beam at the A0 photoinjector in the emittance exchange line. After reporting the CSR power measurements, we report on the diagnostic scheme based on a weak skew quad in the emittance exchange line to study the CSR effects on the beam and other beam dynamics. In this work, we have reported on CSR measurements and the effect of skew quad on the dogleg line with the 5-cell turned on and off. We plan to study CSR effects on the bunch with the 5-cell on at larger chirp. This is will not only increase the CSR self-effect but also reduce the beamsize at the screen for convenient beamsize measurements.

  14. Actuator line/Navier–Stokes computations for the MEXICO rotor: comparison with detailed measurements

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Zhu, Wei Jun; Sørensen, Jens Nørkær

    2012-01-01

    In the European collaborative MEXICO (Model Experiments in Controlled Conditions) project, a series of experiments was carried out on a 4.5 m diameter wind turbine rotor to validate numerical diagnostics tools. Here, some of the measured data are compared with computations of the combined actuator...... line/Navier–Stokes (AL/NS) model developed at the Technical University of Denmark. The AL/NS model was combined with a large eddy simulation technique and used to compute the flow past the MEXICO rotor in free air and in the DNW German‐Dutch wind tunnel for three commonly defined test cases at wind...

  15. Comparison between Random Forests, Artificial Neural Networks and Gradient Boosted Machines Methods of On-Line Vis-NIR Spectroscopy Measurements of Soil Total Nitrogen and Total Carbon

    Directory of Open Access Journals (Sweden)

    Said Nawar

    2017-10-01

    Full Text Available Accurate and detailed spatial soil information about within-field variability is essential for variable-rate applications of farm resources. Soil total nitrogen (TN and total carbon (TC are important fertility parameters that can be measured with on-line (mobile visible and near infrared (vis-NIR spectroscopy. This study compares the performance of local farm scale calibrations with those based on the spiking of selected local samples from both fields into an European dataset for TN and TC estimation using three modelling techniques, namely gradient boosted machines (GBM, artificial neural networks (ANNs and random forests (RF. The on-line measurements were carried out using a mobile, fiber type, vis-NIR spectrophotometer (305–2200 nm (AgroSpec from tec5, Germany, during which soil spectra were recorded in diffuse reflectance mode from two fields in the UK. After spectra pre-processing, the entire datasets were then divided into calibration (75% and prediction (25% sets, and calibration models for TN and TC were developed using GBM, ANN and RF with leave-one-out cross-validation. Results of cross-validation showed that the effect of spiking of local samples collected from a field into an European dataset when combined with RF has resulted in the highest coefficients of determination (R2 values of 0.97 and 0.98, the lowest root mean square error (RMSE of 0.01% and 0.10%, and the highest residual prediction deviations (RPD of 5.58 and 7.54, for TN and TC, respectively. Results for laboratory and on-line predictions generally followed the same trend as for cross-validation in one field, where the spiked European dataset-based RF calibration models outperformed the corresponding GBM and ANN models. In the second field ANN has replaced RF in being the best performing. However, the local field calibrations provided lower R2 and RPD in most cases. Therefore, from a cost-effective point of view, it is recommended to adopt the spiked European dataset

  16. THE PHOTOMETRIC AND KINEMATIC STRUCTURE OF FACE-ON DISK GALAXIES. II. INTEGRATED LINE PROFILE CHARACTERIZATION AND THE ORIGIN OF LINE PROFILE ASYMMETRY

    International Nuclear Information System (INIS)

    Andersen, David R.; Bershady, Matthew A.

    2009-01-01

    We perform a moments analysis of H I and H II global line profiles for 33 nearly face-on disk galaxies for the threefold purpose of rationalizing and interpreting line profile indices in the literature, presenting robust moment definitions with analytic error functions calibrated against Monte Carlo simulation, and probing the physical origin of line profile asymmetries. The first four profile moments serve as viable surrogates for the recession velocity, line width, asymmetry, and profile shape, respectively. The first three moments are superior, by a factor of ∼2 in precision, to related quantities defined in the literature. First and third profile moments are related; skew can be used to calculate more accurate recession velocities from global profiles. Second and fourth profile moments are linked, corresponding to the known trend that narrow (but well resolved) line widths tend to be more Gaussian. Hα kurtosis also appears correlated with the spatially resolved line width of the ionized gas. No systematics appear between various measures of line width and true rotation speed other than the wide range of normalizations, which we calibrate. This conclusion and calibration, however, is highly sample dependent. The ratio of H II to H I widths is consistent with unity, even at low projected line width. There may be a trend toward a decrease in the ratio of H II to H I widths consistent with previous studies, but we also observe greater scatter. While there is good agreement between H I and H II first, second, and fourth moments, we find no positive correlation between skew measured from H I and H II profiles. Detailed analysis of the spatially resolved Hα distribution demonstrates that H II global profile asymmetries are dominated by differences in the gas distribution, not kinematic asymmetries.

  17. Correcting for variable laser-target distances of laser-induced breakdown spectroscopy measurements with ChemCam using emission lines of Martian dust spectra

    Energy Technology Data Exchange (ETDEWEB)

    Melikechi, N.; Mezzacappa, A. [Optical Science Center for Applied Research, Delaware State University, Dover, DE (United States); Cousin, A.; Lanza, N.L. [Los Alamos National Laboratory, Los Alamos, NM (United States); Lasue, J. [Institut de Recherche en Astophysique et Planetologie (IRAP), Universite' Paul Sabatier, Toulouse (France); Clegg, S.M. [Los Alamos National Laboratory, Los Alamos, NM (United States); Berger, G. [Institut de Recherche en Astophysique et Planetologie (IRAP), Universite' Paul Sabatier, Toulouse (France); Wiens, R.C. [Los Alamos National Laboratory, Los Alamos, NM (United States); Maurice, S. [Institut de Recherche en Astophysique et Planetologie (IRAP), Universite' Paul Sabatier, Toulouse (France); Tokar, R.L.; Bender, S. [Planetary Science Institute, Flagstaff, AZ (United States); Forni, O. [Institut de Recherche en Astophysique et Planetologie (IRAP), Universite' Paul Sabatier, Toulouse (France); Breves, E.A.; Dyar, M.D. [Dept. of Astronomy, Mount Holyoke College, South Hadley, MA (United States); Frydenvang, J. [The Niels Bohr Institute, University of Copenhagen, Copenhagen (Denmark); Delapp, D. [Los Alamos National Laboratory, Los Alamos, NM (United States); Gasnault, O. [Institut de Recherche en Astophysique et Planetologie (IRAP), Universite' Paul Sabatier, Toulouse (France); Newsom, H.; Ollila, A.M. [Earth and Planetary Sciences, University of New Mexico, Alburquerque, NM (United States); Lewin, E. [Institut des Sciences de la Terre, Universite Grenoble l-CNRS, Grenoble (France); and others

    2014-06-01

    As part of the Mars Science Laboratory, the ChemCam instrument acquires remote laser induced breakdown spectra at distances that vary between 1.56 m and 7 m. This variation in distance affects the intensities of the measured LIBS emission lines in non-trivial ways. To determine the behavior of a LIBS emission line with distance, it is necessary to separate the effects of many parameters such as laser energy, laser spot size, target homogeneity, and optical collection efficiency. These parameters may be controlled in a laboratory on Earth but for field applications or in space this is a challenge. In this paper, we show that carefully selected ChemCam LIBS emission lines acquired from the Martian dust can be used to build an internal proxy spectroscopic standard. This in turn, allows for a direct measurement of the effects of the distance of various LIBS emission lines and hence can be used to correct ChemCam LIBS spectra for distance variations. When tested on pre-launch LIBS calibration data acquired under Martian-like conditions and with controlled and well-calibrated targets, this approach yields much improved agreement between targets observed at various distances. This work lays the foundation for future implementation of automated routines to correct ChemCam spectra for differences caused by variable distance. - Highlights: • Selected Martian dust emission lines are used to correct for variable laser-target distances. • The correction model yields improved agreement between targets observed at various distances. • The impact of the model reduces the bias between predicted and actual compositions by as much as 70%. • When implemented, the model will yield spectral corrections for various ChemCam measurements. • This work is a foundation to perform novel stand-off LIBS measurements on Earth and other planets.

  18. The NRPI multi-purpose on-line monitoring station for measurement of natural radioactivity in the ambient atmosphere and in the soil

    International Nuclear Information System (INIS)

    Jilek, K.; Slezakova, M.; Fronka, A.; Prokop, T.; Neubauer, L.

    2017-01-01

    During years 2010 12 an automated, on-line and wireless outdoor measurement station of atmospheric radon, gamma dose rate and meteorological parameters was realised at the National Radiation Protection Institute (NRPI) in Prague. At the turn of the year 2013 an expansion of the existing station was completed. Under the project funded by the Czech Technological Agency a new updated station was established, additionally equipped with modules for measurement of atmospheric radon/thoron short-lived decay products, radon in water and soil and radon exhalation rate from soil. After the introduction of the station updated key detection parameters and benefits, its use for atmospheric modelling and monitoring is demonstrated. There are summarised results from the 3-year measurement period in the NRPI outdoor area in Prague and from simultaneous annual measurement performed by another similar station located near uranium mud fields in DIAMO, state enterprise, Straz pod Ralskem. Observed seasonal and diurnal variations of atmospheric radon concentrations and variability of the equilibrium factor, F, are illustrated and compared. (authors)

  19. Atomic emission spectroscopy for the on-line monitoring of incineration processes

    NARCIS (Netherlands)

    Timmermans, E.A.H.; de Groote, F.P.J.; Jonkers, J.; Gamero, A.; Sola, A.; Mullen, van der J.J.A.M.

    2003-01-01

    A diagnostic measurement system based on atomic emission spectroscopy has been developed for the purpose of on-line monitoring of hazardous elements in industrial combustion gases. The aim was to construct a setup with a high durability for rough and variable experimental conditions, e.g. a strongly

  20. On-line nuclear ash gauge for coal based on gamma-ray transmission techniques

    International Nuclear Information System (INIS)

    Rizk, R.A.M.; El-Kateb, A.H.; Abdul-Kader, A.M.

    1999-01-01

    Developments and applications of on-line nuclear gauges in the coal industry are highly requested. A nuclear ash gauge for coal, based on γ-ray transmission techniques is developed. Single and dual energy γ-ray beams are used to determine the ash content of coal. The percentage ash content as a function of the γ-ray intensities transmitted through coal samples is measured and sensitivity curves are obtained. An empirical formulation relating the ash content values to the γ-ray intensities is derived. Preliminary results show that both single and dual energy γ-ray transmission techniques can be used to give a rapid on-line estimation of the ash concentration values in coal with low cost and reasonable accuracy, but the dual one is much preferable. (author)

  1. Precise predictions of H2O line shapes over a wide pressure range using simulations corrected by a single measurement

    Science.gov (United States)

    Ngo, N. H.; Nguyen, H. T.; Tran, H.

    2018-03-01

    In this work, we show that precise predictions of the shapes of H2O rovibrational lines broadened by N2, over a wide pressure range, can be made using simulations corrected by a single measurement. For that, we use the partially-correlated speed-dependent Keilson-Storer (pcsdKS) model whose parameters are deduced from molecular dynamics simulations and semi-classical calculations. This model takes into account the collision-induced velocity-changes effects, the speed dependences of the collisional line width and shift as well as the correlation between velocity and internal-state changes. For each considered transition, the model is corrected by using a parameter deduced from its broadening coefficient measured for a single pressure. The corrected-pcsdKS model is then used to simulate spectra for a wide pressure range. Direct comparisons of the corrected-pcsdKS calculated and measured spectra of 5 rovibrational lines of H2O for various pressures, from 0.1 to 1.2 atm, show very good agreements. Their maximum differences are in most cases well below 1%, much smaller than residuals obtained when fitting the measurements with the Voigt line shape. This shows that the present procedure can be used to predict H2O line shapes for various pressure conditions and thus the simulated spectra can be used to deduce the refined line-shape parameters to complete spectroscopic databases, in the absence of relevant experimental values.

  2. Line-on-line organic-organic heteroepitaxy of quaterrylene on hexa-peri-hexabenzocoronene on Au(111).

    Science.gov (United States)

    Kasemann, Daniel; Wagner, Christian; Forker, Roman; Dienel, Thomas; Müllen, Klaus; Fritz, Torsten

    2009-11-03

    In a recent paper, we discussed the optical properties of a heterostructure consisting of a highly ordered monolayer of quaterrylene (QT), electronically decoupled from the gold substrate by a predeposited epitaxial monolayer of hexa-peri-hexabenzocoronene (HBC). Here we now present the detailed structural investigation of this organic double-layer system. We show that the structure of the heterosystem can be identified as line-on-line coincidence (lol), a new type of epitaxy discovered by us previously for the system 3,4,9,10-perylenetetracarboxylic dianhydride (PTCDA) on HBC on highly oriented pyrolytic graphite (HOPG). Additionally, we provide evidence on the basis of advanced potential energy calculations that indeed energetic gain drives this lol growth mode.

  3. A new lithium-ion battery internal temperature on-line estimate method based on electrochemical impedance spectroscopy measurement

    Science.gov (United States)

    Zhu, J. G.; Sun, Z. C.; Wei, X. Z.; Dai, H. F.

    2015-01-01

    The power battery thermal management problem in EV (electric vehicle) and HEV (hybrid electric vehicle) has been widely discussed, and EIS (electrochemical impedance spectroscopy) is an effective experimental method to test and estimate the status of the battery. Firstly, an electrochemical-based impedance matrix analysis for lithium-ion battery is developed to describe the impedance response of electrochemical impedance spectroscopy. Then a method, based on electrochemical impedance spectroscopy measurement, has been proposed to estimate the internal temperature of power lithium-ion battery by analyzing the phase shift and magnitude of impedance at different ambient temperatures. Respectively, the SoC (state of charge) and temperature have different effects on the impedance characteristics of battery at various frequency ranges in the electrochemical impedance spectroscopy experimental study. Also the impedance spectrum affected by SoH (state of health) is discussed in the paper preliminary. Therefore, the excitation frequency selected to estimate the inner temperature is in the frequency range which is significantly influenced by temperature without the SoC and SoH. The intrinsic relationship between the phase shift and temperature is established under the chosen excitation frequency. And the magnitude of impedance related to temperature is studied in the paper. In practical applications, through obtaining the phase shift and magnitude of impedance, the inner temperature estimation could be achieved. Then the verification experiments are conduced to validate the estimate method. Finally, an estimate strategy and an on-line estimation system implementation scheme utilizing battery management system are presented to describe the engineering value.

  4. A model-based approach to on-line process disturbance management

    International Nuclear Information System (INIS)

    Kim, I.S.

    1988-01-01

    The methodology developed can be applied to the design of a real-time expert system to aid control-room operators in coping with process abnormalities. The approach encompasses diverse functional aspects required for an effective on-line process disturbance management: (1) intelligent process monitoring and alarming, (2) on-line sensor data validation, (3) on-line sensor and hardware (except sensors) fault diagnosis, and (4) real-time corrective measure synthesis. Accomplishment of these functions is made possible through the application of various models, goal-tree success-tree, process monitor-tree, sensor failure diagnosis, and hardware failure diagnosis models. The models used in the methodology facilitate not only the knowledge-acquisition process - a bottleneck in the development of an expert system - but also the reasoning process of the knowledge-based system. These transparent models and model-based reasoning significantly enhance the maintainability of the real-time expert systems. The proposed approach was applied to the feedwater control system of a nuclear power plant, and implemented into a real-time expert system, MOAS II, using the expert system shell, PICON, on the LMI machine

  5. Reports in the area sensor technology: Part 2: Dynamic deviations which may appear via the sensing lines in measurement of reactor pressure and level

    International Nuclear Information System (INIS)

    Bergdahl, Bengt-Goeran

    2002-12-01

    The sensors are part of the safety system in a nuclear power plant. They are the first link in a chain of components, which affect the safety system. It is therefore of great importance that the sensors fulfil tough requirements on reliability and response time. In practice, the dynamic qualities of the sensors in a BWR are seldom, or never, tested. The static qualities, on the other hand, are controlled every year when the transmitters are calibrated. This is done during the regular outage of the power plant. It is common that several sensors are connected to the same sensing line. This is true especially in old reactors, where only a few pressure taps are available in the reactor pressure vessel. This is a troublesome disadvantage in the design, since a failure in one sensing line will affect all components, which are connected to that sensing line ('Common Cause Failure'). This report focuses on deviations in the measurement system connected to the sensing lines. The deviations are illustrated by examples from Swedish and foreign BWRs. The sensing lines are mechanically passive components. They can reduce a system's response time even if there are now deviations in the static presentation. This report mentions cases in nuclear power plants, where the time constant of the sensing line has changed from 0.1 seconds, which is a normal response time, to 5 seconds. This has happened because of a gradual blockage of the sensing line. Today, signal analysis is the only way to examine the dynamic qualities of sensing lines. Filtrations can be unveiled by measuring and analysing the transmitter signal, regardless the location of the filtration: in the sensing line, in the transmitter or in other instrumentation components. A practical case is presented where pulsation dampers with so-called needles were used at Ringhals 1 in Sweden. Their influence on the response time for the measurement signal corresponds to a time constant = 0.55 s. By eliminating the needles the

  6. Precision measurements of high-energy conversion electron lines and determination of neutron binding energies

    International Nuclear Information System (INIS)

    Braumandl, F.

    1979-01-01

    The paper first discusses the energy accuracy of the BILL conversion electron spectrometer at the Grenoble high flux reactor. With an improved temperature stabilisation of the magnets, an energy accuracy of ΔE/E -5 can be reached. After this, highly exact measurements of high-energy conversion electron lines of the 200 Hg, 114 Cd, 165 Dy, 168 Er, 239 U nuclei and the 13 C, 28 Al 3 H and 92 Zr photoelectron lines were carried out. Energy calibration of the spectrometer was carried out in the 1.5 MeV to 6.5 MeV range with intensive high-energy transitions of the 200 Hg nucleus. Systematic calibration errors could be investigated by means of combinations between the calibration lines. A calibration for absolute energies was obtained by comparing low-energy gamma transitions of 200 Hg with the 411.8 keV gold standard. (orig.) [de

  7. On-line implant reconstruction in HDR brachytherapy

    International Nuclear Information System (INIS)

    Kolkman-Deurloo, Inger-Karine K.; Kruijf, Wilhelmus J.M. de; Levendag, Peter C.

    2006-01-01

    Background and purpose: To evaluate the accuracy of on-line planning in an Integrated Brachytherapy Unit (IBU) using dedicated image distortion correction algorithms, correcting the geometric distortion and magnetic distortion separately, and to determine the effect of the reconstruction accuracy on clinical treatment plans in terms of deviations in treatment time and dose. Patients and methods: The reconstruction accuracy has been measured using 20 markers, positioned at well known locations in a QA phantom. Treatment plans of two phantoms representing clinical implant geometries, have been compared with reference plans to determine the effect of the reconstruction accuracy on the treatment plan. Before clinical introduction, treatment plans of three representative patients, based on on-line reconstruction, have been compared with reference plans. Results: The average reconstruction error for 10 in. images reduces from -0.6 mm (range -2.6 to +1.0 mm) to -0.2 mm (range -1.2 to +0.6 mm) after image distortion correction and for 15 in. images from 0.8 mm (range -0.5 to +3.0 mm) to 0.0 mm (range -0.8 to +0.8 mm). The error in case of eccentric positioning of the phantom, i.e. 0.8 mm (range -1.0 to +3.3 mm), reduces to 0.1 mm (range -0.5 to +0.9 mm). Correction of the image distortions reduces the deviation in the calculated treatment time of maximally 2.7% to less than 0.8% in case of eccentrically positioned clinical phantoms. The deviation in the treatment time or reference dose in the plans based on on-line reconstruction with image distortion correction of the three patient examples is smaller than 0.3%. Conclusions: Accurate on-line implant reconstruction using the IBU localiser and dedicated correction algorithms separating the geometric distortion and the magnetic distortion is possible. The results fulfill the minimum requirements as imposed by the Netherlands Commission on Radiation Dosimetry (NCS) without limitations regarding the usable range of the field

  8. Optimization and Improvement of Test Processes on a Production Line

    Science.gov (United States)

    Sujová, Erika; Čierna, Helena

    2018-06-01

    The paper deals with increasing processes efficiency at a production line of cylinder heads of engines in a production company operating in the automotive industry. The goal is to achieve improvement and optimization of test processes on a production line. It analyzes options for improving capacity, availability and productivity of processes of an output test by using modern technology available on the market. We have focused on analysis of operation times before and after optimization of test processes at specific production sections. By analyzing measured results we have determined differences in time before and after improvement of the process. We have determined a coefficient of efficiency OEE and by comparing outputs we have confirmed real improvement of the process of the output test of cylinder heads.

  9. First Calorimetric Measurement of OI-line in the Electron Capture Spectrum of $^{163}$Ho

    CERN Document Server

    Ranitzsch, P. C. -O.; Wegner, M.; Kempf, S.; Fleischmann, A.; Enss, C.; Gastaldo, L.; Herlert, A.; Johnston, K.

    2014-01-01

    The isotope $^{163}$Ho undergoes an electron capture process with a recommended value for the energy available to the decay, $Q_{\\rm EC}$, of about 2.5 keV. According to the present knowledge, this is the lowest $Q_{\\rm EC}$ value for electron capture processes. Because of that, $^{163}$Ho is the best candidate to perform experiments to investigate the value of the electron neutrino mass based on the analysis of the calorimetrically measured spectrum. We present for the first time the calorimetric measurement of the atomic de-excitation of the $^{163}$Dy daughter atom upon the capture of an electron from the 5s shell in $^{163}$Ho, OI-line. The measured peak energy is 48 eV. This measurement was performed using low temperature metallic magnetic calorimeters with the $^{163}$Ho ion implanted in the absorber. We demonstrate that the calorimetric spectrum of $^{163}$Ho can be measured with high precision and that the parameters describing the spectrum can be learned from the analysis of the data. Finally, we dis...

  10. Experimental research and numerical simulation on cryogenic line chill-down process

    Science.gov (United States)

    Jin, Lingxue; Cho, Hyokjin; Lee, Cheonkyu; Jeong, Sangkwon

    2018-01-01

    The empirical heat transfer correlations are suggested for the fast cool down process of the cryogenic transfer line from room temperature to cryogenic temperature. The correlations include the heat transfer coefficient (HTC) correlations for single-phase gas convection and film boiling regimes, minimum heat flux (MHF) temperature, critical heat flux (CHF) temperature and CHF. The correlations are obtained from the experimental measurements. The experiments are conducted on a 12.7 mm outer diameter (OD), 1.25 mm wall thickness and 7 m long stainless steel horizontal pipe with liquid nitrogen (LN2). The effect of the lengthwise position is verified by measuring the temperature profiles in near the inlet and the outlet of the transfer line. The newly suggested heat transfer correlations are applied to the one-dimensional homogeneous transient model to simulate the cryogenic line chill-down process, and the chill-down time and the cryogen consumption are well predicted in the mass flux range from 26.0 kg/m2 s to 73.6 kg/m2 s through the correlations.

  11. A New Precision Measurement of the Small-scale Line-of-sight Power Spectrum of the Lyα Forest

    Science.gov (United States)

    Walther, Michael; Hennawi, Joseph F.; Hiss, Hector; Oñorbe, Jose; Lee, Khee-Gan; Rorai, Alberto; O’Meara, John

    2018-01-01

    We present a new measurement of the Lyα forest power spectrum at 1.8 masking missing data, damped Lyα absorption systems, and metal absorption lines. Our measurement results in unprecedented precision on the small-scale modes k> 0.02 {{s}} {{km}}-1, inaccessible to previous SDSS/BOSS analyses. It is well known that these high-k modes are highly sensitive to the thermal state of the intergalactic medium, but contamination by narrow metal lines is a significant concern. We quantify the effect of metals on the small-scale power and find a modest effect on modes with kmasking metals and restricting to kmasking as our data are generated from Lyα forest simulations. These mock spectra are used to build a custom emulator, enabling us to interpolate between a sparse grid of models and perform Markov chain Monte Carlo fits. Our results agree well with BOSS on scales kdata set for precisely constraining the thermal history of the intergalactic medium, cosmological parameters, and the nature of dark matter. The power spectra and their covariance matrices are provided as electronic tables.

  12. Measuring service line competitive position. A systematic methodology for hospitals.

    Science.gov (United States)

    Studnicki, J

    1991-01-01

    To mount a broad effort aimed at improving their competitive position for some service or group of services, hospitals have begun to pursue product line management techniques. A few hospitals have even reorganized completely under the product line framework. The benefits include focusing accountability for operations and results, facilitating coordination between departments and functions, stimulating market segmentation, and promoting rigorous examination of new and existing programs. As part of its strategic planning process, a suburban Baltimore hospital developed a product line management methodology with six basic steps: (1) define the service lines (which they did by grouping all existing diagnosis-related groups into 35 service lines), (2) determine the contribution of each service line to total inpatient volume, (3) determine trends in service line volumes (by comparing data over time), (4) derive a useful comparison group (competing hospitals or groups of hospitals with comparable size, scope of services, payer mix, and financial status), (5) review multiple time frames, and (6) summarize the long- and short-term performance of the hospital's service lines to focus further analysis. This type of systematic and disciplined analysis can become part of a permanent strategic intelligence program. When hospitals have such a program in place, their market research, planning, budgeting, and operations will be tied together in a true management decision support system.

  13. Moving contact lines on vibrating surfaces

    Science.gov (United States)

    Solomenko, Zlatko; Spelt, Peter; Scott, Julian

    2017-11-01

    Large-scale simulations of flows with moving contact lines for realistic conditions generally requires a subgrid scale model (analyses based on matched asymptotics) to account for the unresolved part of the flow, given the large range of length scales involved near contact lines. Existing models for the interface shape in the contact-line region are primarily for steady flows on homogeneous substrates, with encouraging results in 3D simulations. Introduction of complexities would require further investigation of the contact-line region, however. Here we study flows with moving contact lines on planar substrates subject to vibrations, with applications in controlling wetting/dewetting. The challenge here is to determine the change in interface shape near contact lines due to vibrations. To develop further insight, 2D direct numerical simulations (wherein the flow is resolved down to an imposed slip length) have been performed to enable comparison with asymptotic theory, which is also developed further. Perspectives will also be presented on the final objective of the work, which is to develop a subgrid scale model that can be utilized in large-scale simulations. The authors gratefully acknowledge the ANR for financial support (ANR-15-CE08-0031) and the meso-centre FLMSN for use of computational resources. This work was Granted access to the HPC resources of CINES under the allocation A0012B06893 made by GENCI.

  14. Reliability analysis of minimum energy on target for laser facilities with more beam lines

    International Nuclear Information System (INIS)

    Chen Guangyu

    2008-01-01

    Shot reliability performance measures of laser facilities with more beam lines pertain to three categories: minimum-energy-on-target, power balance, and shot diagnostics. Accounting for symmetry of NIF beam line design and similarity of subset reliability in a same partition, a fault tree of meeting minimum-energy-on-target for the large laser facility shot of type K and a simplified method are presented, which are used to analyze hypothetic reliability of partition subsets in order to get trends of influences increasing number of beam lines and diverse shot types of large laser facilities on their shot reliability. Finally, it finds that improving component reliability is more crucial for laser facilities with more beam lines in comparison with those with beam lines and functional diversity from design flexibility is greatly helpful for improving shot reliability. (authors)

  15. Cross-National Applicability of a Parsimonious Measure of Acculturation to Global Consumer Culture.

    Science.gov (United States)

    Gupta, Nitin

    2016-04-01

    Durvasula and Lysonski's paper presented a shorter version of the Acculturation to Global Consumer Culture Scale (hereafter AGCC), which was developed by Cleveland and Laroche to address scarcity of measurements that determined how individuals acquired and became a part of the emerging global consumer culture. The following critique discusses a few concerns and three major shortcomings of the paper, including skewed sample frame and incorrect choice of countries for assessing cross-national applicability of the scale, not discussing the differences in the means of the seven distinct dimensions of AGCC across the four nations studied by the authors, and absence of any critical review of existing consumer acculturation scales vis-à-vis AGCC. © The Author(s) 2016.

  16. Validation of the actuator line method using near wake measurements of the MEXICO rotor

    DEFF Research Database (Denmark)

    Nilsson, Karl; Shen, Wen Zhong; Sørensen, Jens Nørkær

    2015-01-01

    The purpose of the present work is to validate the capability of the actuator line method to compute vortex structures in the near wake behind the MEXICO experimental wind turbine rotor. In the MEXICO project/MexNext Annex, particle image velocimetry measurements have made it possible to determine...

  17. Measuring Input Thresholds on an Existing Board

    Science.gov (United States)

    Kuperman, Igor; Gutrich, Daniel G.; Berkun, Andrew C.

    2011-01-01

    A critical PECL (positive emitter-coupled logic) interface to Xilinx interface needed to be changed on an existing flight board. The new Xilinx input interface used a CMOS (complementary metal-oxide semiconductor) type of input, and the driver could meet its thresholds typically, but not in worst-case, according to the data sheet. The previous interface had been based on comparison with an external reference, but the CMOS input is based on comparison with an internal divider from the power supply. A way to measure what the exact input threshold was for this device for 64 inputs on a flight board was needed. The measurement technique allowed an accurate measurement of the voltage required to switch a Xilinx input from high to low for each of the 64 lines, while only probing two of them. Directly driving an external voltage was considered too risky, and tests done on any other unit could not be used to qualify the flight board. The two lines directly probed gave an absolute voltage threshold calibration, while data collected on the remaining 62 lines without probing gave relative measurements that could be used to identify any outliers. The PECL interface was forced to a long-period square wave by driving a saturated square wave into the ADC (analog to digital converter). The active pull-down circuit was turned off, causing each line to rise rapidly and fall slowly according to the input s weak pull-down circuitry. The fall time shows up as a change in the pulse width of the signal ready by the Xilinx. This change in pulse width is a function of capacitance, pulldown current, and input threshold. Capacitance was known from the different trace lengths, plus a gate input capacitance, which is the same for all inputs. The pull-down current is the same for all inputs including the two that are probed directly. The data was combined, and the Excel solver tool was used to find input thresholds for the 62 lines. This was repeated over different supply voltages and

  18. Gaussian process tomography for the analysis of line-integrated measurements in fusion plasmas

    International Nuclear Information System (INIS)

    Li, Dong

    2014-01-01

    In nuclear fusion research, a variety of diagnostics have been devised for the measurements of different physical quantities, such as electromagnetic radiation in different wavelength intervals. The radiation, including the soft X-ray spectral range, H α emission as well as others, can be recorded by specifically designed detectors with different sampling frequencies. Commonly, only the line-integrated observations are possible due to the fact that the detectors have to view the plasma from a position outside of the plasma. Therefore, tomography algorithms have been developed to infer the local information of the targeted physical variable from a number of line-integrated data. This thesis presents a Bayesian Gaussian Process Tomographic (GPT) method applied to both soft X-ray and bolometer systems. For the ill-posed inversion problem of reconstructing a 2D emissivity distribution from a number of noisy line-integrated data, Bayesian probability theory can provide a posterior probability distribution about many possible solutions centered at a single most probable solution. The combination of Gaussian Process (GP) prior and multivariate normal (MVN) likelihood enables the posterior probability to be a MVN distribution which provides both the solution and its associated uncertainty. The GP prior enforces the regularization on smoothness by adjusting the length-scale defined in a covariance function. Particularly, a non-stationary GP has been developed to improve the accuracy of reconstruction by using locally adaptive length-scales to take into account the varying smoothness at different positions. The parameters embedded in the model assumption can be optimized through maximizing a joint probability of them based on a Bayesian Occam's razor formalism. In contrast with other tomographic techniques, this method is analytic and non-iterative, thus it can be fast enough for real-time applications under an approximate optimization state. The uncertainty of the

  19. On-line and bulk analysis of iron ore and bauxite

    International Nuclear Information System (INIS)

    Holmes, R.J.; Roczniok, A.F.

    1983-01-01

    A number of analysis techniques based on neutron and gamma radiation have been developed for the mining industry. Current projects include the measurement of annihilation radiation arising from pair production for the on-line determination of the iron content of iron ores, and the construction of a demonstration bauxite analyser based on fast-neutron activation analysis for the simultaneous determination of aluminium and silicon content

  20. On-line test of power distribution prediction system for boiling water reactors

    International Nuclear Information System (INIS)

    Nishizawa, Y.; Kiguchi, T.; Kobayashi, S.; Takumi, K.; Tanaka, H.; Tsutsumi, R.; Yokomi, M.

    1982-01-01

    A power distribution prediction system for boiling water reactors has been developed and its on-line performance test has proceeded at an operating commercial reactor. This system predicts the power distribution or thermal margin in advance of control rod operations and core flow rate change. This system consists of an on-line computer system, an operator's console with a color cathode-ray tube, and plant data input devices. The main functions of this system are present power distribution monitoring, power distribution prediction, and power-up trajectory prediction. The calculation method is based on a simplified nuclear thermal-hydraulic calculation, which is combined with a method of model identification to the actual reactor core state. It has been ascertained by the on-line test that the predicted power distribution (readings of traversing in-core probe) agrees with the measured data within 6% root-mean-square. The computing time required for one prediction calculation step is less than or equal to 1.5 min by an HIDIC-80 on-line computer