WorldWideScience

Sample records for parotid-sparing intensity modulated

  1. Recurrence in Region of Spared Parotid Gland After Definitive Intensity-Modulated Radiotherapy for Head and Neck Cancer

    International Nuclear Information System (INIS)

    Cannon, Donald M.; Lee, Nancy Y.

    2008-01-01

    Purpose: To discuss the implications of three examples of periparotid recurrence after definitive intensity-modulated radiotherapy (IMRT) for head and neck cancer (HNC). Methods and Materials: We present 3 patients with HNC who underwent definitive IMRT with concurrent chemotherapy and later had treatment failure in or near a spared parotid gland. Two patients had bilateral multilevel nodal disease, and all had Level II nodal disease ipsilateral to the site of recurrence. The patients were treated using dose-painting IMRT with a dose of 70 Gy to the gross tumor volume and 59.4 Gy or 54 Gy to the high-risk or low-risk clinical tumor volume, respectively. The parotid glands were spared bilaterally. The patients had not undergone any surgical treatment for HNC before radiotherapy. Results: All patients had treatment failure in the region of a spared parotid gland. Failure in the 2 patients with bilateral multilevel nodal involvement occurred in the periparotid lymph nodes. The third patient developed a dermal metastasis near the tail of a spared parotid gland. On pretreatment imaging, the 2 patients with nodal failure had small nonspecific periparotid nodules that showed no hypermetabolic activity on positron emission tomography. Conclusion: For HNC patients receiving definitive IMRT, nonspecific positron emission tomography-negative periparotid nodules on pretreatment imaging should raise the index of suspicion for subclinical disease in the presence of multilevel or Level II nodal metastases. Additional evaluation of such nodules might be indicated before sparing the ipsilateral parotid gland

  2. Intensity-modulated radiation therapy for nasopharyngeal carcinoma parotid sparing with euivalent uiform dose optimization

    International Nuclear Information System (INIS)

    Yue Weiyou; Dai Jianrong; Gao Li

    2006-01-01

    Objective: The aim of this study was to evaluate the role of an euivalent uiform dose (EUD) based optimization algorithm in sparing the parotids of patients with nasopharyngeal carcinoma (NPC) when they are treated with intensity-modulated radiation therapy (IMRT). Methods: 12 patients were randomly selected from the NPC patients who received IMRT treatments. For these patients, the treatment plans were designed with physical optimization constraints (dose/dose-volume constraints). Based on these plans, new plans were designed through replacing the physical constraints with maximum EUD for parotids, while keeping the physical objectives for targets and other organs at risk(OARs) unchanged. Comparison was then made between the new plan, which had EUD constraints to parotids, and the former for each individual patient. Results: While maintaining the dose to the targets and the other OARs un- changed, optimization with EUD constraints to parotids decreased the mean dose and V 30 of parotids significantly, simultaneously, the dose of target volume and other organs at risk keep stable, the values of probability were less than 0.05 by T-test. Conclusions: The doses to parotids can be reduced through optimization with EUD constraints. This finding is quite helpful to reduce the occurrence rate of parotid complications, and to provide spaces for escalating target dose. (authors)

  3. Parotid-sparing intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma: Preserved parotid function after IMRT on quantitative salivary scintigraphy, and comparison with historical data after conventional radiotherapy

    International Nuclear Information System (INIS)

    Hsiung, C.-Y.; Ting, H.-M.; Huang, H.-Y.; Lee, C.-H.; Huang, E.-Y.; Hsu, H.-C.

    2006-01-01

    Purpose: To evaluate the parotid function after parotid-sparing intensity-modulated radiotherapy (IMRT) in patients with nasopharyngeal carcinoma (NPC). Methods and Materials: From March 2003 to May 2004, 16 patients with nonmetastatic NPC underwent parotid-sparing IMRT. Eight of these patients had Stage III or IV NPC based on the 1997 American Joint Committee on Cancer staging system. The post-IMRT parotid function was evaluated by quantitative salivary scintigraphy and represented by the maximal excretion ratio (MER) of the parotid gland after sialogogue stimulation. The parotid function of 16 NPC patients who were previously treated with conventional radiotherapy was reviewed as the historical control. Results: In the parotid-sparing IMRT group, all 16 patients were alive and without cancer at the end of follow-up period (median, 24.2 months). The mean parotid MER was 53.5% before radiotherapy, 10.7% at 1 month post-IMRT, and 23.3% at 9 months post-IMRT. In the conventional radiotherapy group, the mean parotid MER was 0.6% at 6 to 12 months postradiotherapy. The difference was statistically significant (23.3% vs. 0.6%, p < 0.001, Mann-Whitney test). In the IMRT group, the mean parotid doses ranged from 33.2 Gy to 58.8 Gy (average, 43.9 Gy). The correlation between the mean parotid dose and the percentage decrease of parotid MER at 9 months post-IMRT (dMER) was statically significant (p = 0.008, Pearson correlation). Conclusions: Although the mean parotid doses are relatively high, the significant preservation of parotid function is achieved with IMRT for NPC patients. The significant correlation between mean parotid dose and parotid dMER demonstrates the dose-function relationship of the parotid gland

  4. Geometric factors influencing dosimetric sparing of the parotid glands using IMRT

    International Nuclear Information System (INIS)

    Hunt, Margie A.; Jackson, Andrew; Narayana, Ashwatha; Lee, Nancy

    2006-01-01

    Purpose/Objective: To determine the relationship between the parotid volume, parotid-planning target volume (PTV) overlap, and dosimetric sparing of the parotid with intensity-modulated radiation therapy (IMRT). Methods and Materials: Parotid data were collected retrospectively for 51 patients treated with simultaneous boost IMRT. Unresectable patients received 54 or 59.4 Gy to subclinical disease, 70 Gy to gross disease. Patients treated postoperatively received 54, 60, and 66 Gy to low-risk, high-risk, and tumor bed regions. Volume and mean dose of each gland and gland segments outside of and overlapping the PTV were collected. Proximity of each gland to each PTV was recorded. Results: Dosimetric sparing (mean dose ≤26.5 Gy) was achieved in 66 of 71 glands with ≤21% parotid-PTV overlap and 8 of 23 glands with >21% overlap (p = 21%. Median mean dose was 25.9 Gy to glands overlapping PTV 54 or PTV 59 alone and 30.0 Gy to those abutting PTV 7 (p 7 was associated with higher parotid dose, satisfactory sparing was achieved in 24 of 43 ipsilateral glands. Conclusions: Dosimetric sparing of the parotid is feasible when the parotid-PTV overlap is less than approximately 20%. With more overlap, sparing may result in low doses within the overlap region, possibly leading to inadequate PTV coverage. Gland proximity to the high-dose PTV is associated with higher mean dose but does not always preclude dosimetric sparing

  5. Factors influencing the parotid function in nasopharyngeal carcinoma treated with parotid-sparing radiotherapy

    International Nuclear Information System (INIS)

    Liu Wenshan; Lee Jongkang; Su Maochang; Lee, S.P.; Chen Ginden; Lee Hongshen; Lee Huei

    2006-01-01

    The background of this study was to evaluate the factors influencing post-irradiation parotid gland function in nasopharyngeal cancer treated with parotid-sparing radiotherapy. This study consisted of 45 patients with nasopharyngeal cancer treated with radiotherapy including 3D conformal radiotherapy, intensity-modulated radiotherapy and high-dose-rate brachytherapy. The mean follow-up time was 37.5 months (range: 15-50 months). Objective parotid gland function was assessed by series sialoscintigraphy pre-irradiation and post-irradiation at 1, 6, 12 and 18 months. Subjective salivary function was recorded by the LENT/SOMA system. Wilcoxon signed-rank test was used to compare the secretion ratio (SR) of parotid gland before and after treatment. Mann-Whitney rank-sum test was used to determine the factors influencing the post-irradiated SR. Chi-square test was used to compare the correlation between subjective grading of xerostomia and objective grading of parotid glands. There was a significant difference between the pre-irradiation and post-irradiation parotid gland's SR at 1 (0.30 versus 0.01, P 0.05) and 18 months (0.30 versus 0.18, P>0.05). There was significant correlation between subjective and objective salivary function (P=0.024) at 12 months after radiotherapy. The factor that impacted the preservation of parotid function was mean dose to the parotid gland >38.0 Gy (P<0.05). Our results demonstrated that parotid function could recover 1 year after treatment with parotid-sparing radiotherapy in patients with nasopharyngeal cancer. The most important factor that influenced parotid function was the mean dose to the parotid gland. (author)

  6. Incorporating single-side sparing in models for predicting parotid dose sparing in head and neck IMRT

    International Nuclear Information System (INIS)

    Yuan, Lulin; Wu, Q. Jackie; Yin, Fang-Fang; Yoo, David; Jiang, Yuliang; Ge, Yaorong

    2014-01-01

    Purpose: Sparing of single-side parotid gland is a common practice in head-and-neck (HN) intensity modulated radiation therapy (IMRT) planning. It is a special case of dose sparing tradeoff between different organs-at-risk. The authors describe an improved mathematical model for predicting achievable dose sparing in parotid glands in HN IMRT planning that incorporates single-side sparing considerations based on patient anatomy and learning from prior plan data. Methods: Among 68 HN cases analyzed retrospectively, 35 cases had physician prescribed single-side parotid sparing preferences. The single-side sparing model was trained with cases which had single-side sparing preferences, while the standard model was trained with the remainder of cases. A receiver operating characteristics (ROC) analysis was performed to determine the best criterion that separates the two case groups using the physician's single-side sparing prescription as ground truth. The final predictive model (combined model) takes into account the single-side sparing by switching between the standard and single-side sparing models according to the single-side sparing criterion. The models were tested with 20 additional cases. The significance of the improvement of prediction accuracy by the combined model over the standard model was evaluated using the Wilcoxon rank-sum test. Results: Using the ROC analysis, the best single-side sparing criterion is (1) the predicted median dose of one parotid is higher than 24 Gy; and (2) that of the other is higher than 7 Gy. This criterion gives a true positive rate of 0.82 and a false positive rate of 0.19, respectively. For the bilateral sparing cases, the combined and the standard models performed equally well, with the median of the prediction errors for parotid median dose being 0.34 Gy by both models (p = 0.81). For the single-side sparing cases, the standard model overestimates the median dose by 7.8 Gy on average, while the predictions by the combined

  7. Predictive factors of local-regional recurrences following parotid sparing intensity modulated or 3D conformal radiotherapy for head and neck cancer

    International Nuclear Information System (INIS)

    Feng, Mary; Jabbari, Siavash; Lin, Alexander; Bradford, Carol R.; Chepeha, Douglas B.; Teknos, Theodoros N.; Worden, Francis P.; Tsien, Christina; Schipper, Matthew J.; Wolf, Gregory T.; Dawson, Laura A.; Eisbruch, Avraham

    2005-01-01

    Background and purpose: Predictive factors for local-regional (LR) failures after parotid-sparing, Intensity modulated (IMRT) or 3D conformal radiotherapy for head and neck (HN) cancers were assessed. Patients and methods: One hundred and fifty-eight patients with mostly stages III-IV HN squamous cell carcinoma underwent curative bilateral neck irradiation aimed at sparing the parotid glands. Patient, tumor, and treatment factors were analyzed as predictive factors for LR failure. Results: Twenty-three patients had LR recurrence (19 in-field and four marginal). No differences were found in the doses delivered to the PTVs of patients with or without in-field recurrences. In univariate analysis, tumor site was highly predictive for LR failure in both postoperative and definitive RT patients. In postoperative RT patients, pathologic tumor size, margin status, extracapsular extension (ECE) and number of lymph node metastases, were also significantly predictive. Multivariate analysis showed tumor site (oropharynx vs. other sites) to be a significant predictor in all patients, and involved margins and number of involved lymph nodes in postoperative patients. Conclusions: Clinical rather than dosimetric factors predicted for LR failures in this series, and were similar to those reported following standard RT. These factors may aid in the selection of patients for studies of treatment intensification using IMRT

  8. Impact of residual setup error on parotid gland dose in intensity-modulated radiation therapy with or without planning organ-at-risk margin

    International Nuclear Information System (INIS)

    Delana, Anna; Menegotti, Loris; Valentini, Aldo; Bolner, Andrea; Tomio, Luigi; Vanoni, Valentina; Lohr, Frank

    2009-01-01

    Purpose: To estimate the dosimetric impact of residual setup errors on parotid sparing in head-and-neck (H and N) intensity-modulated treatments and to evaluate the effect of employing an PRV (planning organ-at-risk volume) margin for the parotid gland. Patients and methods: Ten patients treated for H and N cancer were considered. A nine-beam intensity-modulated radiotherapy (IMRT) was planned for each patient. A second optimization was performed prescribing dose constraint to the PRV of the parotid gland. Systematic setup errors of 2 mm, 3 mm, and 5 mm were simulated. The dose-volume histograms of the shifted and reference plans were compared with regard to mean parotid gland dose (MPD), normal-tissue complication probability (NTCP), and coverage of the clinical target volume (V 95% and equivalent uniform dose [EUD]); the sensitivity of parotid sparing on setup error was evaluated with a probability-based approach. Results: MPD increased by 3.4%/mm and 3.0%/mm for displacements in the craniocaudal and lateral direction and by 0.7%/mm for displacements in the anterior-posterior direction. The probability to irradiate the parotid with a mean dose > 30 Gy was > 50%, for setup errors in cranial and lateral direction and 95% and EUD variations < 1% and < 1 Gy). Conclusion: The parotid gland is more sensitive to craniocaudal and lateral displacements. A setup error of 2 mm guarantees an MPD ≤ 30 Gy in most cases, without adding a PRV margin. If greater displacements are expected/accepted, an adequate PRV margin could be used to meet the clinical parotid gland constraint of 30 Gy, without affecting target volume coverage. (orig.)

  9. Patterns of local-regional recurrence following parotid-sparing conformal and segmental intensity-modulated radiotherapy for head and neck cancer

    International Nuclear Information System (INIS)

    Dawson, Laura A.; Anzai, Yoshimi; Marsh, Lon; Martel, Mary K.; Paulino, Augusto; Ship, Jonathan A.; Eisbruch, Avraham

    2000-01-01

    Purpose: To analyze the patterns of local-regional recurrence in patients with head and neck cancer treated with parotid-sparing conformal and segmental intensity-modulated radiotherapy (IMRT). Methods and Materials: Fifty-eight patients with head and neck cancer were treated with bilateral neck radiation (RT) using conformal or segmental IMRT techniques, while sparing a substantial portion of one parotid gland. The targets for CT-based RT planning included the gross tumor volume (GTV) (primary tumor and lymph node metastases) and the clinical target volume (CTV) (postoperative tumor bed, expansions of the GTVs and lymph node groups at risk of subclinical disease). Lymph node targets at risk of subclinical disease included the bilateral jugulodigastric and lower jugular lymph nodes, bilateral retropharyngeal lymph nodes at risk, and high jugular nodes at the base of skull in the side of the neck at highest risk (containing clinical neck metastases and/or ipsilateral to the primary tumor). The CTVs were expanded by 5 mm to yield planning target volumes (PTVs). Planning goals included coverage of all PTVs (with a minimum of 95% of the prescribed dose) and sparing of a substantial portion of the parotid gland in the side of the neck at less risk. The median RT doses to the gross tumor, the operative bed, and the subclinical disease PTVs were 70.4 Gy, 61.2 Gy, and 50.4 Gy respectively. All recurrences were defined on CT scans obtained at the time of recurrence, transferred to the pretreatment CT dataset used for RT planning, and analyzed using dose-volume histograms. The recurrences were classified as 1) 'in-field', in which 95% or more of the recurrence volume (V recur ) was within the 95% isodose; 2) 'marginal', in which 20% to 95% of V recur was within the 95% isodose; or 3) 'outside', in which less than 20% of V recur was within the 95% isodose. Results: With a median follow-up of 27 months (range 6 to 60 months), 10 regional recurrences, 5 local recurrences

  10. Patterns of local-regional recurrence following parotid-sparing conformal and segmental intensity-modulated radiotherapy for head and neck cancer.

    Science.gov (United States)

    Dawson, L A; Anzai, Y; Marsh, L; Martel, M K; Paulino, A; Ship, J A; Eisbruch, A

    2000-03-15

    To analyze the patterns of local-regional recurrence in patients with head and neck cancer treated with parotid-sparing conformal and segmental intensity-modulated radiotherapy (IMRT). Fifty-eight patients with head and neck cancer were treated with bilateral neck radiation (RT) using conformal or segmental IMRT techniques, while sparing a substantial portion of one parotid gland. The targets for CT-based RT planning included the gross tumor volume (GTV) (primary tumor and lymph node metastases) and the clinical target volume (CTV) (postoperative tumor bed, expansions of the GTVs and lymph node groups at risk of subclinical disease). Lymph node targets at risk of subclinical disease included the bilateral jugulodigastric and lower jugular lymph nodes, bilateral retropharyngeal lymph nodes at risk, and high jugular nodes at the base of skull in the side of the neck at highest risk (containing clinical neck metastases and/or ipsilateral to the primary tumor). The CTVs were expanded by 5 mm to yield planning target volumes (PTVs). Planning goals included coverage of all PTVs (with a minimum of 95% of the prescribed dose) and sparing of a substantial portion of the parotid gland in the side of the neck at less risk. The median RT doses to the gross tumor, the operative bed, and the subclinical disease PTVs were 70.4 Gy, 61.2 Gy, and 50.4 Gy respectively. All recurrences were defined on CT scans obtained at the time of recurrence, transferred to the pretreatment CT dataset used for RT planning, and analyzed using dose-volume histograms. The recurrences were classified as 1) "in-field," in which 95% or more of the recurrence volume (V(recur)) was within the 95% isodose; 2) "marginal," in which 20% to 95% of V(recur) was within the 95% isodose; or 3) "outside," in which less than 20% of V(recur) was within the 95% isodose. With a median follow-up of 27 months (range 6 to 60 months), 10 regional recurrences, 5 local recurrences (including one noninvasive recurrence) and 1

  11. Intensity-modulated radiotherapy vs. parotid-sparing 3D conformal radiotherapy. Effect on outcome and toxicity in locally advanced head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lambrecht, M.; Nevens, D.; Nuyts, S. [University Hospitals Leuven (Belgium). Dept. of Radiation Oncology

    2013-03-15

    Background and purpose: Intensity-modulated radiotherapy (IMRT) has rapidly become standard of care in the management of locally advanced head and neck squamous cell carcinoma (HNSCC). In this study, our aim was to retrospectively investigate the effect of the introducing IMRT on outcome and treatment-related toxicity compared to parotid-sparing 3D conformal radiotherapy (3DCRT). Material and methods: A total of 245 patients with stage III and IV HNSCC treated with primary radiotherapy between January 2003 and December 2010 were included in this analysis: 135 patients were treated with 3DCRT, 110 patients with IMRT. Groups were compared for acute and late toxicity, locoregional control (LRC), and overall survival (OS). Oncologic outcomes were estimated using Kaplan-Meier analysis and compared using a log-rank test. Acute toxicity was analyzed according to the Common Terminology Criteria for Adverse Events v3.0 and late toxicity was scored using the RTOG/EORTC late toxicity scoring system. Results: Median follow-up was 35 months in the IMRT group and 68 months in the 3DCRT group. No significant differences were found in 3-year LRC and OS rates between the IMRT group and 3DCRT group. Significantly less acute mucositis {>=} grade 3 was observed in the IMRT group (32% vs. 44%, p = 0.03). There was significantly less late xerostomia {>=} grade 2 in the IMRT group than in the 3DCRT group (23% vs. 68%, p < 0.001). After 24 months, there was less dysphagia {>=} grade 2 in the IMRT group although differences failed to reach statistical significance. Conclusion: The introduction of IMRT in the radiotherapeutic management of locally advanced head and neck cancer significantly improved late toxicity without compromising tumor control compared to a parotid-sparing 3D conformal radiotherapy technique. (orig.)

  12. Parotid gland sparing IMRT for head and neck cancer improves xerostomia related quality of life

    International Nuclear Information System (INIS)

    Rij, CM van; Oughlane-Heemsbergen, WD; Ackerstaff, AH; Lamers, EA; Balm, AJM; Rasch, CRN

    2008-01-01

    To assess the impact of intensity modulated radiotherapy (IMRT) versus conventional radiation on late xerostomia and Quality of Life aspects in head and neck cancer patients. Questionnaires on xerostomia in rest and during meals were sent to all patients treated between January 1999 and December 2003 with a T1-4, N0-2 M0 head and neck cancer, with parotid gland sparing IMRT or conventional bilateral neck irradiation to a dose of at least 60 Gy, who were progression free and had no disseminated disease (n = 192). Overall response was 85% (n = 163); 97% in the IMRT group (n = 75) and 77% in the control group (n = 88) the median follow-up was 2.6 years. The prevalence of complaints was compared between the two groups, correcting for all relevant factors at multivariate ordinal regression analysis. Patients treated with IMRT reported significantly less difficulty transporting and swallowing their food and needed less water for a dry mouth during day, night and meals. They also experienced fewer problems with speech and eating in public. Laryngeal cancer patients in general had fewer complaints than oropharynx cancer patients but both groups benefited from IMRT. Within the IMRT group the xerostomia scores were better for those patients with a mean parotid dose to the 'spared' parotid below 26 Gy. Parotid gland sparing IMRT for head and neck cancer patients improves xerostomia related quality of life compared to conventional radiation both in rest and during meals. Laryngeal cancer patients had fewer complaints but benefited equally compared to oropharyngeal cancer patients from IMRT

  13. Parotid gland sparing IMRT for head and neck cancer improves xerostomia related quality of life

    Science.gov (United States)

    van Rij, CM; Oughlane-Heemsbergen, WD; Ackerstaff, AH; Lamers, EA; Balm, AJM; Rasch, CRN

    2008-01-01

    Background and purpose To assess the impact of intensity modulated radiotherapy (IMRT) versus conventional radiation on late xerostomia and Quality of Life aspects in head and neck cancer patients. Patients and nethods Questionnaires on xerostomia in rest and during meals were sent to all patients treated between January 1999 and December 2003 with a T1-4, N0-2 M0 head and neck cancer, with parotid gland sparing IMRT or conventional bilateral neck irradiation to a dose of at least 60 Gy, who were progression free and had no disseminated disease (n = 192). Overall response was 85% (n = 163); 97% in the IMRT group (n = 75) and 77% in the control group (n = 88) the median follow-up was 2.6 years. The prevalence of complaints was compared between the two groups, correcting for all relevant factors at multivariate ordinal regression analysis. Results Patients treated with IMRT reported significantly less difficulty transporting and swallowing their food and needed less water for a dry mouth during day, night and meals. They also experienced fewer problems with speech and eating in public. Laryngeal cancer patients in general had fewer complaints than oropharynx cancer patients but both groups benefited from IMRT. Within the IMRT group the xerostomia scores were better for those patients with a mean parotid dose to the "spared" parotid below 26 Gy. Conclusion Parotid gland sparing IMRT for head and neck cancer patients improves xerostomia related quality of life compared to conventional radiation both in rest and during meals. Laryngeal cancer patients had fewer complaints but benefited equally compared to oropharyngeal cancer patients from IMRT. PMID:19068126

  14. Parotid gland sparing IMRT for head and neck cancer improves xerostomia related quality of life

    Directory of Open Access Journals (Sweden)

    Balm AJM

    2008-12-01

    Full Text Available Abstract Background and purpose To assess the impact of intensity modulated radiotherapy (IMRT versus conventional radiation on late xerostomia and Quality of Life aspects in head and neck cancer patients. Patients and nethods Questionnaires on xerostomia in rest and during meals were sent to all patients treated between January 1999 and December 2003 with a T1-4, N0-2 M0 head and neck cancer, with parotid gland sparing IMRT or conventional bilateral neck irradiation to a dose of at least 60 Gy, who were progression free and had no disseminated disease (n = 192. Overall response was 85% (n = 163; 97% in the IMRT group (n = 75 and 77% in the control group (n = 88 the median follow-up was 2.6 years. The prevalence of complaints was compared between the two groups, correcting for all relevant factors at multivariate ordinal regression analysis. Results Patients treated with IMRT reported significantly less difficulty transporting and swallowing their food and needed less water for a dry mouth during day, night and meals. They also experienced fewer problems with speech and eating in public. Laryngeal cancer patients in general had fewer complaints than oropharynx cancer patients but both groups benefited from IMRT. Within the IMRT group the xerostomia scores were better for those patients with a mean parotid dose to the "spared" parotid below 26 Gy. Conclusion Parotid gland sparing IMRT for head and neck cancer patients improves xerostomia related quality of life compared to conventional radiation both in rest and during meals. Laryngeal cancer patients had fewer complaints but benefited equally compared to oropharyngeal cancer patients from IMRT.

  15. Utilization of intensity modulated beam radiotherapy (IMBXRT) to diminish dose to the parotid gland in head and neck cancer

    International Nuclear Information System (INIS)

    Shiao, W. Woo; Grant, Walter H.; Butler, E. Brian

    1996-01-01

    Purpose/Objective: To determine if intensity conformal modulated radiotherapy could diminish the radiation dose to the parotid gland in the treatment of primary head and neck cancer. Materials and Methods: The NOMOS Peacock treatment system was utilized in the planning and delivery of conformal radiotherapy for the following diseases: 1) an oropharyngeal cancer that extends from the soft palate to the tonsillar fossa without nodal disease, 2) laryngeal hypopharyngeal cancer without nodal disease, 3) and adenocystic carcinoma, that originated in the hard palate. Patients were treated to areas suspicious for microscopic disease (nodal disease in 1 and 2, perineural spread in 3) at 2 Gy per fraction for a tc of 50 Gy in five weeks. The primary disease was treated at 2.4 Gy per fraction for a total of 60 Gy over five weeks. The percent of the volume of each parotid gland receiving < 20 Gy, <25 Gy and <30 Gy retrospectively was determined for each of the above mentioned optimized plans. The patients were observed for the clinical development of xerostomia. Results: No patient developed clinically apparent xerostomia within one month of completion of radiotherapy. Conclusion: IMBXRT could reduce the volume to parotid glands receiving high radiation doses. Sparing of the parotid glands appear to be most easily accomplished when irradiating head and neck tumors that do not require regional nodal treatment. For head and neck cancer that requires nodal treatment it is possible to spare a significant portion of the parotid glands if the disease originates below the hyoid bone where the primary site is not in close proximity to the parotid glands. Objective salivary flow data are being obtained pre ar post treatment, to confirm the subjective impression of lack of clinical xerostomia. IMBXRT is potentially beneficial in decreasing the morbidity of xerostomia related to head and neck irradiation

  16. Using a Reduced Spot Size for Intensity-Modulated Proton Therapy Potentially Improves Salivary Gland-Sparing in Oropharyngeal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Water, Tara A. van de, E-mail: t.a.van.de.water@rt.umcg.nl [Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen (Netherlands); Lomax, Antony J. [Centre for Proton Therapy, Paul Scherrer Institute, Villigen-PSI (Switzerland); Bijl, Hendrik P.; Schilstra, Cornelis [Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen (Netherlands); Hug, Eugen B. [Centre for Proton Therapy, Paul Scherrer Institute, Villigen-PSI (Switzerland); Langendijk, Johannes A. [Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen (Netherlands)

    2012-02-01

    Purpose: To investigate whether intensity-modulated proton therapy with a reduced spot size (rsIMPT) could further reduce the parotid and submandibular gland dose compared with previously calculated IMPT plans with a larger spot size. In addition, it was investigated whether the obtained dose reductions would theoretically translate into a reduction of normal tissue complication probabilities (NTCPs). Methods: Ten patients with N0 oropharyngeal cancer were included in a comparative treatment planning study. Both IMPT plans delivered simultaneously 70 Gy to the boost planning target volume (PTV) and 54 Gy to the elective nodal PTV. IMPT and rsIMPT used identical three-field beam arrangements. In the IMPT plans, the parotid and submandibular salivary glands were spared as much as possible. rsIMPT plans used identical dose-volume objectives for the parotid glands as those used by the IMPT plans, whereas the objectives for the submandibular glands were tightened further. NTCPs were calculated for salivary dysfunction and xerostomia. Results: Target coverage was similar for both IMPT techniques, whereas rsIMPT clearly improved target conformity. The mean doses in the parotid glands and submandibular glands were significantly lower for three-field rsIMPT (14.7 Gy and 46.9 Gy, respectively) than for three-field IMPT (16.8 Gy and 54.6 Gy, respectively). Hence, rsIMPT significantly reduced the NTCP of patient-rated xerostomia and parotid and contralateral submandibular salivary flow dysfunction (27%, 17%, and 43% respectively) compared with IMPT (39%, 20%, and 79%, respectively). In addition, mean dose values in the sublingual glands, the soft palate and oral cavity were also decreased. Obtained dose and NTCP reductions varied per patient. Conclusions: rsIMPT improved sparing of the salivary glands and reduced NTCP for xerostomia and parotid and submandibular salivary dysfunction, while maintaining similar target coverage results. It is expected that rsIMPT improves quality

  17. Dosimetry of parotid glands in IMRT plan of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Lian Jiancheng; Yu Xinsheng; Jiang Guoliang

    2007-01-01

    Objective: To evaluate the effect of different intensity-modulated radiation therapy (IMRT) plan on the dosimetry of parotid in patients with nasopharyngeal carcinoma. Methods: Under the same constraints and objections, the IMRT plan of nasopharyngeal carcinoma with sparing unilateral parotid and the IMRT plan added plan tumor volume (PTV) margin for parotid gland was investigated. Results: Between conventional IMRT plan and the IMRT plan spared unilateral parotid, their target coverage, homogeneity index and conformal index of PTV 70 is similar. On PTV 60 , D min in the plan of sparing one parotid gland was more than that in normal IMRT plan (P 95 in the plan of sparing one parotid gland have improved (P 50%VOL and D mean of parotid gland were similar between the two plans. Between conventional IMRT plan and the IMRT plan added 2 or 3 mm margin for parotid gland, their target coverage, homogeneity index and conformal index of PTV 70 is similar. D min , D mean and D 95 of PTV 60 have decreased tendency from normal IMRT plan to 2 mm margin plan to 3 mm margin plan. D max of brainstem and spine cord have increased tendency from normal IMRT plan to 2 mm margin plan to 3 mm margin plan. Conclusions: The IMRT plan of nasopharyngeal carcinoma with sparing unilateral parotid may be adopted not to protect both two parotids, while PTV margin for parotid added as parotid move. (authors)

  18. Can sparing of the superficial contralateral parotid lobe reduce xerostomia following radiotherapy for head and neck cancer?

    Science.gov (United States)

    Nevens, Daan; Nuyts, Sandra

    2017-12-01

    The purpose of this study is to see whether sparing the superficial contralateral parotid lobe can help limiting xerostomia following radiotherapy for head and neck cancer. 88 patients that were included in two prospective randomized studies were analysed in the current study. Using the dosimetry of both the parotid glands, we divided our patients in four groups. Group 1 includes patients where we were able to reduce the radiation dose below the threshold in order to spare both the ipsilateral and contralateral parotid glands, Group 2 consists of patients where only the contralateral parotid gland could be spared. Group 3 consists of patients where only the contralateral superficial parotid lobe could be spared, while in Group 4 not even the contralateral superficial lobe could be spared. When we compared Group 1 and Group 2, we did not observe a significant difference between both groups in terms of xerostomia scores at 6 or 12 months. When we compared these groups with Group 3, we observed significant differences with more xerostomia in Group 3 where only the contralateral superficial lobe was spared. A significant difference was also observed between Group 3 and Group 4 with more xerostomia in Group 4. Sparing of just one superficial parotid lobe results in less xerostomia when compared to not sparing any lobe of both parotid glands. Advances in knowledge: When sparing of the whole contralateral parotid gland is not possible, delineating both the superficial parotid glands and trying to spare at least one of them can mean a way forward in limiting xerostomia in head and neck cancer patients treated with radiotherapy.

  19. Parotid Gland Sparing With Helical Tomotherapy in Head-and-Neck Cancer

    International Nuclear Information System (INIS)

    Voordeckers, Mia; Farrag, Ashraf; Everaert, Hendrik; Tournel, Koen; Storme, Guy; Verellen, Dirk; De Ridder, Mark

    2012-01-01

    parotid volume as planning goals. Intensity-modulated radiotherapy should be considered as standard treatment in patients with head-and-neck cancer.

  20. Sparing of the submandibular glands by intensity modulated radiotherapy in the treatment of head and neck cancer

    International Nuclear Information System (INIS)

    Saarilahti, Kauko; Kouri, Mauri; Collan, Juhani; Kangasmaeki, Aki; Atula, Timo; Joensuu, Heikki; Tenhunen, Mikko

    2006-01-01

    Background and purpose: The submandibular glands produce most of the unstimulated saliva output and are the key in prevention of radiation-related xerostomia. We investigated whether sparing of the submandibular function is feasible with intensity modulated radiotherapy (IMRT). Patients and methods: Thirty-six patients diagnosed with head and neck cancer were treated with IMRT and had at least one parotid gland excluded from the planning target volume. In a subset, of these patients (n=18) where the risk of cancer recurrence in the contralateral submandibular region was judged low, the contralateral submandibular gland was spared from full-dose irradiation. The total unstimulated and stimulated salivary flow rates and adverse effects were monitored. Results: Twelve months following IMRT mean unstimulated saliva flow was 60% of the baseline value among patients who had one submandibular gland spared and 25% among those who did not (P=0.006). Patients whose contralateral submandibular was spared reported less grade two or three xerostomia (4 vs. 11; P=0.018), and used less saliva substitutes. No cancer recurrences were detected at the vicinity of the spared glands during a median follow-up time of 31 months. Conclusions: Submandibular gland sparing with IMRT is safe in selected patients treated for head and neck cancer. It is effective in prevention of radiation-associated xerostomia

  1. Intensity Modulated Radiotherapy Improves Target Coverage and Parotid Gland Sparing When Delivering Total Mucosal Irradiation in Patients With Squamous Cell Carcinoma of Head and Neck of Unknown Primary Site

    International Nuclear Information System (INIS)

    Bhide, Shreerang; Clark, Catherine; Harrington, Kevin; Nutting, Christopher M.

    2007-01-01

    Head and neck squamous cell carcinoma with occult primary site represents a controversial clinical problem. Conventional total mucosal irradiation (TMI) maximizes local control, but at the expense of xerostomia. IMRT has been shown to spare salivary tissue in head and cancer patients. This study has been performed to investigate the potential of IMRT to perform nodal and TMI and also allow parotid gland sparing in this patient group. Conventional radiotherapy (CRT) and IMRT plans were produced for six patients to treat the ipsilateral (involved) post-operative neck (PTV1) and the un-operated contralateral neck and mucosal axis (PTV2). Plans were produced with and without the inclusion of nasopharynx in the PTV2. The potential to improve target coverage and spare the parotid glands was investigated for the IMRT plans. There was no significant difference in the mean doses to the PTV1 using CRT and IMRT (59.7 and 60.0 respectively, p = 0.5). The maximum doses to PTV1 and PTV2 were lower for the IMRT technique as compared to CRT (P = 0.008 and P < 0.0001), respectively, and the minimum doses to PTV1 and PTV2 were significantly higher for IMRT as compared to CRT (P = 0.001 and P = 0.001), respectively, illustrating better dose homogeneity with IMRT. The mean dose to the parotid gland contralateral to PTV1 was significantly lower for IMRT (23.21 ± 0.7) as compared to CRT (50.5 ± 5.8) (P < 0.0001). There was a significant difference in parotid dose between plans with and without the inclusion of the nasopharynx. IMRT offers improved dose homogeneity in PTV1 and PTV2 and allows for parotid sparing

  2. 3D-conformal-intensity modulated radiotherapy with compensators for head and neck cancer: clinical results of normal tissue sparing

    Directory of Open Access Journals (Sweden)

    Koscielny Sven

    2006-06-01

    Full Text Available Abstract Background To investigate the potential of parotic gland sparing of intensity modulated radiotherapy (3D-c-IMRT performed with metallic compensators for head and neck cancer in a clinical series by analysis of dose distributions and clinical measures. Materials and methods 39 patients with squamous cell cancer of the head and neck irradiated using 3D-c-IMRT were evaluable for dose distribution within PTVs and at one parotid gland and 38 patients for toxicity analysis. 10 patients were treated primarily, 29 postoperatively, 19 received concomittant cis-platin based chemotherapy, 20 3D-c-IMRT alone. Initially the dose distribution was calculated with Helax ® and photon fluence was modulated using metallic compensators made of tin-granulate (n = 22. Later the dose distribution was calculated with KonRad ® and fluence was modified by MCP 96 alloy compensators (n = 17. Gross tumor/tumor bed (PTV 1 was irradiated up to 60–70 Gy, [5 fractions/week, single fraction dose: 2.0–2.2 (simultaneously integrated boost], adjuvantly irradiated bilateral cervical lymph nodes (PTV 2 with 48–54 Gy [single dose: 1.5–1.8]. Toxicity was scored according the RTOG scale and patient-reported xerostomia questionnaire (XQ. Results Mean of the median doses at the parotid glands to be spared was 25.9 (16.3–46.8 Gy, for tin graulate 26 Gy, for MCP alloy 24.2 Gy. Tin-granulate compensators resulted in a median parotid dose above 26 Gy in 10/22, MCP 96 alloy in 0/17 patients. Following acute toxicities were seen (°0–2/3: xerostomia: 87%/13%, dysphagia: 84%/16%, mucositis: 89%/11%, dermatitis: 100%/0%. No grade 4 reaction was encountered. During therapy the XQ forms showed °0–2/3: 88%/12%. 6 months postRT chronic xerostomia °0–2/3 was observed in 85%/15% of patients, none with °4 xerostomia. Conclusion 3D-c-IMRT using metallic compensators along with inverse calculation algorithm achieves sufficient parotid gland sparing in virtually all advanced

  3. Potential Benefits of Scanned Intensity-Modulated Proton Therapy Versus Advanced Photon Therapy With Regard to Sparing of the Salivary Glands in Oropharyngeal Cancer

    International Nuclear Information System (INIS)

    Water, Tara A. van de; Lomax, Antony J.; Bijl, Hendrik P.; Jong, Marije E. de; Schilstra, Cornelis; Hug, Eugen B.; Langendijk, Johannes A.

    2011-01-01

    Purpose: To test the hypothesis that scanned intensity-modulated proton therapy (IMPT) results in a significant dose reduction to the parotid and submandibular glands as compared with intensity-modulated radiotherapy with photons (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) for oropharyngeal cancer. In addition, we investigated whether the achieved dose reductions would theoretically translate into a reduction of salivary dysfunction and xerostomia. Methods and Materials: Ten patients with N0 oropharyngeal carcinoma were used. The intensity-modulated plans delivered simultaneously 70 Gy to the boost planning target volume (PTV2) and 54 Gy to the elective nodal areas (PTV1). The 3D-CRT technique delivered sequentially 70 Gy and 46 Gy to PTV2 and PTV1, respectively. Normal tissue complication probabilities were calculated for salivary dysfunction and xerostomia. Results: Planning target volume coverage results were similar for IMPT and IMRT. Intensity-modulated proton therapy clearly improved the conformity. The 3D-CRT results were inferior to these results. The mean dose to the parotid glands by 3D-CRT (50.8 Gy), IMRT (25.5 Gy), and IMPT (16.8 Gy) differed significantly. For the submandibular glands no significant differences between IMRT and IMPT were found. The dose reductions obtained with IMPT theoretically translated into a significant reduction in normal tissue complication probability. Conclusion: Compared with IMRT and 3D-CRT, IMPT improved sparing of the organs at risk, while keeping similar target coverage results. The dose reductions obtained with IMPT vs. IMRT and 3D-CRT varied widely per individual patient. Intensity-modulated proton therapy theoretically translated into a clinical benefit for most cases, but this requires clinical validation.

  4. Monitoring Dosimetric Impact of Weight Loss With Kilovoltage (KV) Cone Beam CT (CBCT) During Parotid-Sparing IMRT and Concurrent Chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Kean Fatt, E-mail: hokeanfatt@hotmail.com [Academic Radiation Oncology, The Christie NHS Foundation Trust, Manchester (United Kingdom); Marchant, Tom; Moore, Chris; Webster, Gareth; Rowbottom, Carl [North Western Medical Physics, The Christie NHS Foundation Trust, Manchester (United Kingdom); Penington, Hazel [Wade Radiotherapy Research Centre, The Christie NHS Foundation Trust, Manchester (United Kingdom); Lee, Lip; Yap, Beng; Sykes, Andrew; Slevin, Nick [Department of Clinical Oncology, The Christie NHS Foundation Trust, Manchester (United Kingdom)

    2012-03-01

    Purpose: Parotid-sparing head-and-neck intensity-modulated radiotherapy (IMRT) can reduce long-term xerostomia. However, patients frequently experience weight loss and tumor shrinkage during treatment. We evaluate the use of kilovoltage (kV) cone beam computed tomography (CBCT) for dose monitoring and examine if the dosimetric impact of such changes on the parotid and critical neural structures warrants replanning during treatment. Methods and materials: Ten patients with locally advanced oropharyngeal cancer were treated with contralateral parotid-sparing IMRT concurrently with platinum-based chemotherapy. Mean doses of 65 Gy and 54 Gy were delivered to clinical target volume (CTV)1 and CTV2, respectively, in 30 daily fractions. CBCT was prospectively acquired weekly. Each CBCT was coregistered with the planned isocenter. The spinal cord, brainstem, parotids, larynx, and oral cavity were outlined on each CBCT. Dose distributions were recalculated on the CBCT after correcting the gray scale to provide accurate Hounsfield calibration, using the original IMRT plan configuration. Results: Planned contralateral parotid mean doses were not significantly different to those delivered during treatment (p > 0.1). Ipsilateral and contralateral parotids showed a mean reduction in volume of 29.7% and 28.4%, respectively. There was no significant difference between planned and delivered maximum dose to the brainstem (p = 0.6) or spinal cord (p = 0.2), mean dose to larynx (p = 0.5) and oral cavity (p = 0.8). End-of-treatment mean weight loss was 7.5 kg (8.8% of baseline weight). Despite a {>=}10% weight loss in 5 patients, there was no significant dosimetric change affecting the contralateral parotid and neural structures. Conclusions: Although patient weight loss and parotid volume shrinkage was observed, overall, there was no significant excess dose to the organs at risk. No replanning was felt necessary for this patient cohort, but a larger patient sample will be investigated

  5. Influence of intensity-modulated radiation therapy on parotid function in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Cui Tiantian; Wu Shaoxiong; Han Fei; Lu Lixia; Huang Shaomin; Deng Xiaowu; Lu Taixiang; Zhao Chong

    2009-01-01

    Objective: To evaluate the effect of intensity-modulated radiation therapy (IMRT) on parotid function in nasopharyngeal carcinoma (NPC). Methods: Eighty-three NPC patients received prima- ry IMRT between 2001 and 2003. Xerostomia before radiotherapy, at the end of radiotherapy, at 6-month, 1-, 2-,3-,4- and 5-year after radiotherapy were investigated, respectively. The relation between xerostomia and parotid dose distribution was analyzed. Results: Of all the patients, 4, 31, 31 and 17 had stage I, II, III and IV A disease, respectively. Sixteen patients received chemo-radiotherapy. The median followed-up time was 65 months. The 5-year local control and regional control rate were 96% and 95%, respectively. The 5- year overall survival rate was 80%. The mild xerostomia rate at the seven time points was 42%, 51%, 71%, 77%, 58%, 38% and 26%. The corresponding moderate xerostomia rate was 52%, 53%, 21%, 8%, 3%, 2% and 2%, respectively. No serious xerostomia was observed. The mean dose of the bilateral parotid glands was 34.34 Gy. Xerostomia at 6-month after radiotherapy was positively correlated with the mean dose of the parotid glands, and D 50 was the independent factor in predicting the xerostomia. Parotid function was well protected when the mean dose and D 50 were no more than 33 Gy and 29 Gy, respectively. Conclusions: IMRT can improve the local-regional control of NPC and protect the parotid glands from radiation-induced injury. (authors)

  6. Dosimetric Verification and Evaluation of the 3-D Conformal Parotid Gland-Sparing Irradiation Technique for Bilateral Neck Treatment at University Hospital Centre Zagreb

    International Nuclear Information System (INIS)

    Kovacevic, N; Hrsak, H.; Bibic, J.

    2011-01-01

    3-D Conformal Parotid Gland-Sparing Irradiation Technique for Bilateral Neck (ConPas) is an alternative to Intensity-modulated radiotherapy (IMRT), and is in routine use at University Hospital Centre Rebro (KBC-Rebro), Zagreb. This technique includes highly asymmetric wedged conformal multi-leaf fields and demands very precise application. The aim of this paper is to present the dosimetric verification method of ConPas (and evaluation of ConPas applicability) as performed at KBC, taking into account the precision of the Treatment Planning System (TPS), possibilities of linear accelerator and patient set-up error. Results for two patients are shown in some details.ConPas is a rather sophisticated method and demands high precision in the whole radiotherapy process. Verification of ConPas using IMRT Verification Matrix Phantom shows good agreement between measured and predicted doses inside and outside PTV regions of the head and neck. Furthermore, a careful track of the positioning during the treatment shows that the overall set-up error is very small (practically negligible). When possible, one parotid gland may be partially spared, and therefore its function preserved at least to some extent. (author)

  7. Parotid gland sparing effect by computed tomography-based modified lower field margin in whole brain radiotherapy

    International Nuclear Information System (INIS)

    Cho, Oyeon; Chun, Mi Son; Oh, Young Taek; Kim, Mi Hwa; Park, Hae Jin; Nam, Sang Soo; Heo, Jae Sung; Noh, O Kyu; Park, Sung Ho

    2013-01-01

    Parotid gland can be considered as a risk organ in whole brain radiotherapy (WBRT). The purpose of this study is to evaluate the parotid gland sparing effect of computed tomography (CT)-based WBRT compared to 2-dimensional plan with conventional field margin. From January 2008 to April 2011, 53 patients underwent WBRT using CT-based simulation. Bilateral two-field arrangement was used and the prescribed dose was 30 Gy in 10 fractions. We compared the parotid dose between 2 radiotherapy plans using different lower field margins: conventional field to the lower level of the atlas (CF) and modified field fitted to the brain tissue (MF). Averages of mean parotid dose of the 2 protocols with CF and MF were 17.4 Gy and 8.7 Gy, respectively (p 98% of prescribed dose were 99.7% for CF and 99.5% for MF. Compared to WBRT with CF, CT-based lower field margin modification is a simple and effective technique for sparing the parotid gland, while providing similar dose coverage of the whole brain.

  8. Pre-trial quality assurance processes for an intensity-modulated radiation therapy (IMRT) trial: PARSPORT, a UK multicentre Phase III trial comparing conventional radiotherapy and parotid-sparing IMRT for locally advanced head and neck cancer.

    Science.gov (United States)

    Clark, C H; Miles, E A; Urbano, M T Guerrero; Bhide, S A; Bidmead, A M; Harrington, K J; Nutting, C M

    2009-07-01

    The purpose of this study was to compare conventional radiotherapy with parotid gland-sparing intensity-modulated radiation therapy (IMRT) using the PARSPORT trial. The validity of such a trial depends on the radiotherapy planning and delivery meeting a defined standard across all centres. At the outset, many of the centres had little or no experience of delivering IMRT; therefore, quality assurance processes were devised to ensure consistency and standardisation of all processes for comparison within the trial. The pre-trial quality assurance (QA) programme and results are described. Each centre undertook exercises in target volume definition and treatment planning, completed a resource questionnaire and produced a process document. Additionally, the QA team visited each participating centre. Each exercise had to be accepted before patients could be recruited into the trial. 10 centres successfully completed the quality assurance exercises. A range of treatment planning systems, linear accelerators and delivery methods were used for the planning exercises, and all the plans created reached the standard required for participation in this multicentre trial. All 10 participating centres achieved implementation of a comprehensive and robust IMRT programme for treatment of head and neck cancer.

  9. Parotid gland sparing radiotherapy technique using 3-D conformal radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Lim, Ji Hoon; Kim, Gwi Eon; Keum, Ki Chang; Suh, Chang Ok; Lee, Sang Wook; Park, Hee Chul; Cho, Jae Ho; Chang, Sei Kyung; Loh, Juhn Kyu

    2000-01-01

    Although using the high energy photon beam with conventional parallel-opposed beams radio-therapy for nasopgaryngeal carcinoma, radiation-induced xerostomia is a troublesome problem for patients. We conducted this study to explore a new parotid gland sparing technique in 3-D conformal radiotherapy (3-DCRT) in an effort to prevent the radiation-induced xerostomia. We performed three different planning for four clinically node-negative nasopharyngeal cancer patients with different location of tumor(intracranial extension, nasal cavity extension, oropharyngeal extension, parapharyngeal extension), and intercompared the plans. Total prescription dose was 70.2 Gy to the isocenter. For plan-A, 2-D parallel opposing fields, a conventional radiotherapy technique, were employed. For plan-B, 2-D parallel opposing fields were used up until 54 Gy and afterwards 3-D non-coplanar beams were used. For plan-C, the new technique, 54Gy was delivered by 3-D conformal 3-port beams (AP and both lateral ports with wedge compensator, shielding both superficial lobes of parotid glands at the AP beam using BEV) from the beginning of the treatment and early spinal cord block (at 36 Gy) was performed. And bilateral posterior necks were treated with electron after 36 Gy. After 54 Gy, non-coplanar beams were used for cone-down plan. We intercompared dose statistics (Dmax, Dmin, Dmean, D95, D05, V95, V05, Volume receiving 46 Gy) and dose volume histograms (DVH) of tumor and normal tissues and NTCP values of parotid glands for the above three plans. For all patients, the new technique (plan-C) was comparable or superior to the other plans in target volume isodose distribution and dose statistics and it has more homogenous target volume coverage. The new technique was most superior to the other plans in parotid glands sparing (volume receiving 46 Gy: 100, 98, 69% for each plan-A, B and C). And it showed the lowest NTCP value of parotid glands in all patients (range of NTCP; 96-100%, 79-99%, 51

  10. Intensity-modulated radiotherapy significantly reduces xerostomia compared with conventional radiotherapy

    International Nuclear Information System (INIS)

    Braam, Petra M.; Terhaard, Chris H.J. M.D.; Roesink, Judith M.; Raaijmakers, Cornelis P.J.

    2006-01-01

    Purpose: Xerostomia is a severe complication after radiotherapy for oropharyngeal cancer, as the salivary glands are in close proximity with the primary tumor. Intensity-modulated radiotherapy (IMRT) offers theoretical advantages for normal tissue sparing. A Phase II study was conducted to determine the value of IMRT for salivary output preservation compared with conventional radiotherapy (CRT). Methods and Materials: A total of 56 patients with oropharyngeal cancer were prospectively evaluated. Of these, 30 patients were treated with IMRT and 26 with CRT. Stimulated parotid salivary flow was measured before, 6 weeks, and 6 months after treatment. A complication was defined as a stimulated parotid flow rate <25% of the preradiotherapy flow rate. Results: The mean dose to the parotid glands was 48.1 Gy (SD 14 Gy) for CRT and 33.7 Gy (SD 10 Gy) for IMRT (p < 0.005). The mean parotid flow ratio 6 weeks and 6 months after treatment was respectively 41% and 64% for IMRT and respectively 11% and 18% for CRT. As a result, 6 weeks after treatment, the number of parotid flow complications was significantly lower after IMRT (55%) than after CRT (87%) (p = 0.002). The number of complications 6 months after treatment was 56% for IMRT and 81% for CRT (p = 0.04). Conclusions: IMRT significantly reduces the number of parotid flow complications for patients with oropharyngeal cancer

  11. Preservation of parotid function with uncomplicated conformal radiotherapy

    International Nuclear Information System (INIS)

    Maes, Annelies; Weltens, Caroline; Flamen, Patrick; Lambin, Philippe; Bogaerts, Ria; Liu, Xuan; Baetens, Jan; Hermans, Robert; Van den Bogaert, Walter

    2002-01-01

    Background and purpose: To evaluate (1) parotid function, (2) subjective xerostomia and (3) pattern of relapses after conformal parotid-sparing radiotherapy (RT) for head and neck cancer. (4) To study dose-response curves of parotid glands. Material and methods: From September 1999 to November 2000, 39 head and neck cancer patients requiring bilateral neck RT were treated with a fairly simple conformal RT technique (three-field set-up+anterior lower neck field; two opposed oblique boost fields). The contralateral parotid was spared. Parotid function was assessed by salivary gland scintigraphies performed before, early (median 4 weeks) and late (median 28 weeks) after RT. Xerostomia was monitored by visual analogue scales (VAS) and LENT SOMA scores. Location of locoregional recurrences was studied in relation to the radiation fields. A dose-response curve of parotids was created using logistic regression. Results: (1) Early after RT, on salivary gland scintigraphy, the mean loss of secretion function in the spared parotid was 67% and total in the non-spared. Late after RT, the mean loss remained 19% in the spared and total in the non-spared parotid. Normal excretion function was regained in 75% of the spared parotids. (2) Late after RT, 78% of patients had no, minimal or acceptable subjective xerostomia. (3) No recurrence was seen near the spared parotid (11/39 locoregional recurrences). (4) The dose-response curve of parotids showed that the mean parotid dose should preferentially be ≤20 Gy, to obtain a good chance (≥70%) for preservation of its function on scintigraphy. Conclusions: An easy conformal parotid-sparing RT technique prevents moderate or severe subjective xerostomia in 78% of patients. In the spared parotids, nearly complete to complete recovery is obtained after 6-12 months

  12. The influence of parotid gland sparing on radiation damages of dental hard tissues.

    Science.gov (United States)

    Hey, Jeremias; Seidel, Johannes; Schweyen, Ramona; Paelecke-Habermann, Yvonne; Vordermark, Dirk; Gernhardt, Christian; Kuhnt, Thomas

    2013-07-01

    The aim of the present study was to evaluate whether radiation damage on dental hard tissue depends on the mean irradiation dose the spared parotid gland is subjected to or on stimulated whole salivary flow rate. Between June 2002 and October 2008, 70 patients with neck and cancer curatively irradiated were included in this study. All patients underwent dental treatment referring to the guidelines and recommendations of the German Society of Dental, Oral and Craniomandibular Sciences prior, during, and after radiotherapy (RT). During the follow-up period of 24 months, damages on dental hard tissues were classified according to the RTOG/EORTC guidelines. The mean doses (D(mean)) during spared parotid gland RT were determined. Stimulated whole saliva secretion flow rates (SFR) were measured before RT and 1, 6, 12, 24 months after RT. Thirty patients showed no carious lesions (group A), 18 patients developed sporadic carious lesions (group B), and 22 patients developed general carious lesions (group C). Group A patients received a D mean of 21.2 ± 11.04 Gy. Group B patients received a D(mean) of 26.5 ± 11.59 Gy and group C patients received a D(mean) of 33.9 ± 9.93 Gy, respectively. The D(mean) of group A was significantly lower than the D(mean) of group C (p dental hard tissue correlates with increased mean irradiation doses as well as decreased salivary flow rates. Parotid gland sparing resulting in a dose below 20 Gy reduces radiation damage on dental hard tissues, and therefore, the dose may act as a predictor for the damage to be expected.

  13. Parotid gland-recovery after radiotherapy in the head and neck region - 36 months follow-up of a prospective clinical study

    Directory of Open Access Journals (Sweden)

    Vordermark Dirk

    2011-09-01

    Full Text Available Abstract Background The aim of the present study was to evaluate the recovery potential of the parotid glands after using either 3D-conformal-radiotherapy (3D-CRT or intensity-modulated radiotherapy (IMRT by sparing one single parotid gland. Methods Between 06/2002 and 10/2008, 117 patients with head and neck cancer were included in this prospective, non-randomised clinical study. All patients were treated with curative intent. Salivary gland function was assessed by measuring stimulated salivary flow at the beginning, during and at the end of radiotherapy as well as 1, 6, 12, 24, and 36 months after treatment. Measurements were converted to flow rates and normalized relative to rates before treatment. Mean doses (Dmean were calculated from dose-volume histograms based on computed tomographies of the parotid glands. Results Patients were grouped according to the Dmean of the spared parotid gland having the lowest radiation exposure: Group I - Dmean mean 26-40 Gy (n = 45, and group III - Dmean > 40 Gy (n = 36. 15/117 (13% patients received IMRT. By using IMRT as compared to 3D-CRT the Dmean of the spared parotid gland could be significantly reduced (Dmean IMRT vs. 3D-CRT: 21.7 vs. 34.4 Gy, p Conclusions If a Dmean mean of the parotids, and thus on the saliva flow and recovery of parotid gland.

  14. Function protection of the parotid gland after intensity modulated radiotherapy for thirty-six patients of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Xiao Zemin; Liao Yuping; Jiang Wuzhong; Wu Tao

    2008-01-01

    Objective: To study the parotid gland function protection of intensity modulated radiotherapy (IMRT) for patients with nasopharyngeal carcinoma (NPC) Methods: Thirty-six NPC patients were divided into IMRT group (therapy group) and conventional fraction (CF) group (control group) by random balanced design. Each group had 18 patients. The planning gross tumor volume (pGTV) of nasopharyngeal was treated with a total dose of 72.0 in therapy group, with a total dose of 70.0 Gy in control group (with daily 2.0 Gy/fraction and 5 times/week). Before treatment and at 3, 6, and 9 months, 1 and 2 years after therapy, all patients performed parotid imaging and both uptake index (UI) and excretion index (EI) after acid stimulation were calculated. The dose-volume histogram (DVH) was used to analyse the dose of parotid. Results: The values of UI were 77.6% and 96.2% at the end of therapy and after tow years in therapy group and 56.8% and 7.0% in contrast group. The values of EI were 64.1% and 95.3% at the end of therapy and after tow years in therapy group and 19.4% and 0 in control group. The mean doses of normal side and the trouble side of parotid gland were 20.0 Gy and 31.0 Gy in therapy group and 61.0 Gy and 68.2 Gy in control group. Conclusions: IMRT can reduce radiation dose of parotid glands compared with CF distinctly and thus protect parotid function effectively. (authors)

  15. Xerostomia and its predictors following parotid-sparing irradiation of head-and-neck cancer

    International Nuclear Information System (INIS)

    Eisbruch, Avraham; Kim, Hyungjin M.; Terrell, Jeffrey E.; Marsh, Lon H.C.; Dawson, Laura A.; Ship, Jonathan A.

    2001-01-01

    Purpose: To assess long-term xerostomia in patients receiving parotid-sparing radiation therapy (RT) for head-and-neck cancer, and to find the patient and therapy-related factors that affect its severity. Patients and Methods: From March 1994 through January 2000, 84 patients received comprehensive bilateral neck RT using conformal and multisegmental intensity-modulated RT (IMRT) aiming to spare the major salivary glands. Before RT and periodically through 2 years after the completion of RT, salivary flow rates from each of the major salivary glands were selectively measured. At the same time intervals, each patient completed an 8-item self-reported xerostomia-specific questionnaire (XQ). To gain a relative measure of the effect of RT on the minor salivary glands, whose output could not be measured, the surfaces of the oral cavity (extending to include the surface of the base of tongue) were outlined in the planning CT scans. The mean doses to the new organ ('oral cavity') were recorded. Forty-eight patients receiving unilateral neck RT were similarly studied and served as a benchmark for comparison. Factors predicting the XQ scores were analyzed using a random-effects model. Results: The XQ was found to be reliable and valid in measuring patient-reported xerostomia. The spared salivary glands which had received moderate doses in the bilateral RT group recovered to their baseline salivary flow rates during the second year after RT, and the spared glands in the unilateral RT group, which had received very low doses, demonstrated increased salivary production beyond their pre-RT levels. The increase in the salivary flow rates during the second year after RT paralleled an improvement in xerostomia in both patient groups. The improvement in xerostomia was faster in the unilateral compared with the bilateral RT group, but the difference narrowed at 2 years. The major salivary gland flow rates had only a weak correlation with the xerostomia scores. Factors found to be

  16. Dosimetric study of optimal beam number and arrangement for treatment of nasopharyngeal carcinoma with intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Budrukkar, Ashwini; Corry, June; Peters, Lester J.; Hope, Geoff; Cramb, Jim

    2004-01-01

    The purpose of this dosimetric study was to evaluate the effect of beam number and arrangement on the dose distribution with intensity-modulated radiation therapy in patients with nasopharyngeal cancer. Computed tomography data sets of seven patients who were treated for nasopharyngeal carcinoma at the Peter MacCallum Cancer Centre were used for the present dosimetric study. The dose planned was 70 Gy in 7 weeks for the gross nasopharyngeal and nodal disease and the biological equivalents of 60 Gy in 6 weeks for the high-risk and 50 Gy in 5 weeks for the low-risk nodal disease. A plan using seven fields was compared to that using nine fields in all patients. Plans were assessed on the dose to the planning target volume (PTV) and the degree of parotid sparing achieved by evaluating both dose-volume histograms (DVH) and axial slices. Seven fields (three anterior and four posterior) provide good PTV coverage and satisfactory parotid sparing in patients with localized nasopharyngeal lesions. Nine fields appear to be better for tumours with significant posterolateral parapharyngeal extension. Parotid sparing is consistently better with nine fields. Both DVH and axial slices need to be evaluated before accepting any plan Copyright (2004) Blackwell Publishing Asia Pty Ltd

  17. SU-E-T-809: Volumetric Modulated Arc Radiotherapy Vs. Intensity-Modulated Radiotherapy for Locally Advanced Laryngeal Carcinoma: A Dosimetric Study

    Energy Technology Data Exchange (ETDEWEB)

    Lu, J-Y; Huang, B-T; Zhang, W-Z; Yan, L-J [Cancer Hospital of Shantou University Medical College, Shantou, Guangdong (China)

    2015-06-15

    Purpose: To compare volumetric modulated arc radiotherapy (VMAT) technique with fixed-gantry intensity-modulated radiotherapy (IMRT) technique for locally advanced laryngeal carcinoma. Methods: CT datasets of eleven patients were included. Dual-arc VMAT and 7-field IMRT plans, which were created based on the Eclipse treatment planning system, were compared in terms of dose-volume parameters, conformity index (CI) and homogeneity index (HI) of planning target volume (PTV), as well as organ-at-risk (OAR) sparing, planning time, monitor units (MUs) and delivery time. Results: Compared with the IMRT plans, the VMAT plans provided lower D2% and better CI/HI for the high-risk PTV (PTV1), and provided better CI and comparable HI for the low-risk PTV (PTV2). Concerning the OAR sparing, the VMAT plans demonstrated significantly lower Dmax of the spinal cord (planning OAR volume, PRV) and brainstem (PRV), as well as lower Dmean and V30Gy of the right parotid. No significant differences were observed between the two plans concerning the doses delivered to the thyroid, carotid, oral cavity and left parotid. Moreover, the VMAT planning (147 ± 18 min) consumed 213% more time than the IMRT planning (48 ± 10 min). The MUs of the VMAT plans (556 ± 52) were 64% less than those of the IMRT plans (1684 ± 409), and the average delivery time (2.1 ± 0.1 min) was 66% less than that of the IMRT plans (6.3 ± 0.7 min). Conclusion: Compared with the IMRT technique, the VMAT technique can achieve superior target dose distribution and better sparing of the spinal cord, brainstem and right parotid, with less MUs and less delivery time. It is recommended for the radiotherapy of locally advanced laryngeal carcinoma.

  18. Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniques

    International Nuclear Information System (INIS)

    Nutting, Christopher M.; Rowbottom, Carl G.; Cosgrove, Vivian P.; Henk, J. Michael; Dearnaley, David P.; Robinson, Martin H.; Conway, John; Webb, Steve

    2001-01-01

    Background and purpose: To compare external beam radiotherapy techniques for parotid gland tumours using conventional radiotherapy (RT), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT). To optimise the IMRT techniques, and to produce an IMRT class solution. Materials and methods: The planning target volume (PTV), contra-lateral parotid gland, oral cavity, brain-stem, brain and cochlea were outlined on CT planning scans of six patients with parotid gland tumours. Optimised conventional RT and 3DCRT plans were created and compared with inverse-planned IMRT dose distributions using dose-volume histograms. The aim was to reduce the radiation dose to organs at risk and improve the PTV dose distribution. A beam-direction optimisation algorithm was used to improve the dose distribution of the IMRT plans, and a class solution for parotid gland IMRT was investigated. Results: 3DCRT plans produced an equivalent PTV irradiation and reduced the dose to the cochlea, oral cavity, brain, and other normal tissues compared with conventional RT. IMRT further reduced the radiation dose to the cochlea and oral cavity compared with 3DCRT. For nine- and seven-field IMRT techniques, there was an increase in low-dose radiation to non-target tissue and the contra-lateral parotid gland. IMRT plans produced using three to five optimised intensity-modulated beam directions maintained the advantages of the more complex IMRT plans, and reduced the contra-lateral parotid gland dose to acceptable levels. Three- and four-field non-coplanar beam arrangements increased the volume of brain irradiated, and increased PTV dose inhomogeneity. A four-field class solution consisting of paired ipsilateral coplanar anterior and posterior oblique beams (15, 45, 145 and 170 degree sign from the anterior plane) was developed which maintained the benefits without the complexity of individual patient optimisation. Conclusions: For patients with parotid gland tumours

  19. Dose-Effect Relationships for the Submandibular Salivary Glands and Implications for Their Sparing by Intensity Modulated Radiotherapy

    International Nuclear Information System (INIS)

    Murdoch-Kinch, Carol-Anne; Kim, Hyugnjin M.; Vineberg, Karen A.; Ship, Jonathan; Eisbruch, Avraham

    2008-01-01

    Purpose: Submandibular salivary glands (SMGs) dysfunction contributes to xerostomia after radiotherapy (RT) of head-and-neck (HN) cancer. We assessed SMG dose-response relationships and their implications for sparing these glands by intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 148 HN cancer patients underwent unstimulated and stimulated SMG salivary flow rate measurements selectively from Wharton's duct orifices, before RT and periodically through 24 months after RT. Correlations of flow rates and mean SMG doses were modeled throughout all time points. IMRT replanning in 8 patients whose contralateral level I was not a target incorporated the results in a new cost function aiming to spare contralateral SMGs. Results: Stimulated SMG flow rates decreased exponentially by (1.2%) Gy as mean doses increased up to 39 Gy threshold, and then plateaued near zero. At mean doses ≤39 Gy, but not higher, flow rates recovered over time at 2.2%/month. Similarly, the unstimulated salivary flow rates decreased exponentially by (3%) Gy as mean dose increased and recovered over time if mean dose was <39 Gy. IMRT replanning reduced mean contralateral SMG dose by average 12 Gy, achieving ≤39 Gy in 5 of 8 patients, without target underdosing, increasing the mean doses to the parotid glands and swallowing structures by average 2-3 Gy. Conclusions: SMG salivary flow rates depended on mean dose with recovery over time up to a threshold of 39 Gy. Substantial SMG dose reduction to below this threshold and without target underdosing is feasible in some patients, at the expense of modestly higher doses to some other organs

  20. Influence of Parotid from Various Dose Rate in Intensity Modulated Radiation Therapy Planning for Head and Neck Cancer

    International Nuclear Information System (INIS)

    Hong, Joo Wan; Jeong, Yun Ju; Won, Hui Su; Chang, Nam Jun; Choi, Ji Hun; Seok, Jin Yong

    2010-01-01

    There are various beam parameter in intensity modulated radiation therapy (IMRT). The aim of this study is to investigate how various dose rate affect the parotid in treatment plan of IMRT. Materials and Methods: The study was performed on 10 nasopharyngeal carcinoma patients who have undergone IMRT. CT images were scanned 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). The parameters for planning used 6 MV energy and 8 beams under the same dose volume constraint. The variation of dose rates were used 300, 400, 500 MU/min. The mean dose of both parotid was accessed from the calculated planning among the 10 patients. The mean dose of parotid was verificated by 2D diode array (Mapcheck from Sun Nuclear Corporation, Melbourne, Florida). Also, Total monitor unit (MU) and beam-on time was analysed. Results: According to the dose rate, the mean dose of parotid was increased by 0.8%, 2.0% each, when dose rate was changed from 300 MU/min to 400, 500 MU/min, moreover Total MU was increased by 5.4% and 10.6% each. There was also a dose upward trend in the dose measurement of parotid by 2D diode array. However, beam - on time difference of 1-2 minutes was no significant in the dose rate increases. From this study, when the dose rates increase, there was a significant increase of Total MU and the parotid dose accordingly, however the shortened treatment time was not significant. Hence, it is considered that there is a significant decrease of late side effect in parotid radiation therapy, if the precise dose rate in IMRT is used.

  1. Scintigraphic assessment of salivary function after intensity-modulated radiotherapy for head and neck cancer: correlations with parotid dose and quality of life.

    Science.gov (United States)

    Chen, Wen-Cheng; Lai, Chia-Hsuan; Lee, Tsair-Fwu; Hung, Chao-Hsiung; Liu, Kuo-Chi; Tsai, Ming-Fong; Wang, Wen-Hung; Chen, Hungcheng; Fang, Fu-Ming; Chen, Miao-Fen

    2013-01-01

    We investigated salivary function using quantitative scintigraphy and sought to identify functional correlations between parotid dose and quality of life (QoL) for head and neck cancer (HNC) patients receiving intensity-modulated radiotherapy (IMRT). Between August, 2007 and June, 2008, 31 patients treated IMRT for HNC were enrolled in this prospective study. Salivary excretion function (SEF) was previously measured by salivary scintigraphy at annual intervals for 2 years after IMRT. A dose-volume histogram of each parotid gland was calculated, and the normal tissue complication probability (NTCP) was used to determine the tolerance dose. QoL was longitudinally assessed by the EORTC QLQ-C30 and H&N35 questionnaires prior to RT, and at one, three, 12 and 24 months after RT. A significant correlation was found between the reduction of SEF and the mean parotid dose measured at 1 year (correlation coefficient, R(2)=0.651) and 2 years (R(2)=0.310) after IMRT (pwestern countries. We further found that contralateral parotid and submandibular gland function preservation was correlated with reduced sticky saliva and a better QoL compared to the functional preservation of both parotid glands, as determined by the EORTC QLQ-H&N35 questionnaire. A significant correlation was found between the reduction of SEF and the mean parotid dose. Preservation of contralateral parotid and submandibular gland function predicts a better QoL compared to preservation of the function of both parotid glands. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Carotid sparing intensity modulated radiotherapy on early glottic cancer: Preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hoon Sik; Jeong, Bae Kwon; Jeong, Ho Jin; Song, Jin Ho; Kim, Jin Pyeong; Park, Jung Je; Woo, Seung Hoon; Kang, Ki Mun [Gyeongsang National University Hospital, Gyeongsang National University School of Medicine, Jinju (Korea, Republic of)

    2016-03-15

    To compare the dose distribution between carotid sparing intensity modulated radiotherapy (IMRT) and opposed lateral field technique (LAFT), and to determine the effects of carotid sparing IMRT in early glottic cancer patients who have risk factors for atherosclerosis. Ten early glottic cancer patients were treated with carotid sparing IMRT. For each patient, the conventional LAFT plan was developed for comparison. IMRT and LAFT plans were compared in terms of planning target volume (PTV) coverage, conformity index, homogeneity index, and the doses to planning organ at risk volume (PRV) for carotid arteries, spinal cord and pharyngeal constrictor muscle. Recurrence was not observed in any patients during the follow-up period. V95% for PTV showed no significant difference between IMRT and LAFT plans, while V100% was significantly higher in the IMRT plan (95.5% vs. 94.6%, p = 0.005). The homogeneity index (11.6%) and conformity index (1.4) in the IMRT plan were significantly better than those in the LAFT plans (8.5% and 5.1, respectively) (p = 0.005). The median V5Gy (90.0%), V25Gy (13.5%), and V50Gy (0%) for carotid artery PRV in the IMRT plan were significantly lower than those in the LAFT plan (99.1%, 89.0%, and 77.3%, respectively) (p = 0.005). Our study suggests that carotid sparing IMRT can significantly decrease the dose to carotid arteries compared to LAFT, and it would be considered for early glottic cancer patient with high risk of atherosclerosis.

  3. Anal wall sparing effect of an endorectal balloon in 3D conformal and intensity-modulated prostate radiotherapy.

    NARCIS (Netherlands)

    Smeenk, R.J.; Lin, E.N.J.T. van; Kollenburg, P. van; Kunze-Busch, M.C.; Kaanders, J.H.A.M.

    2009-01-01

    BACKGROUND AND PURPOSE: To investigate the anal wall (Awall) sparing effect of an endorectal balloon (ERB) in 3D conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) for prostate cancer. MATERIALS AND METHODS: In 24 patients with localized prostate carcinoma, two planning

  4. Xerostomia in patients treated for oropharyngeal carcinoma: comparing linear accelerator-based intensity-modulated radiation therapy with helical tomotherapy.

    Science.gov (United States)

    Fortin, Israël; Fortin, Bernard; Lambert, Louise; Clavel, Sébastien; Alizadeh, Moein; Filion, Edith J; Soulières, Denis; Bélair, Manon; Guertin, Louis; Nguyen-Tan, Phuc Felix

    2014-09-01

    In comparison to sliding-window intensity-modulated radiation therapy (sw-IMRT), we hypothesized that helical tomotherapy (HT) would achieve similar locoregional control and, at the same time, decrease the parotid gland dose, thus leading to a xerostomia reduction. The association between radiation techniques, mean parotid dose, and xerostomia incidence, was reviewed in 119 patients with advanced oropharyngeal carcinoma treated with concurrent chemoradiation using sw-IMRT (n = 59) or HT (n = 60). Ipsilateral and contralateral parotid mean doses were significantly lower for patients treated with HT versus sw-IMRT: 24 Gy versus 32 Gy ipsilaterally and 20 Gy versus 25 Gy contralaterally. The incidence of grade ≥2 xerostomia was significantly lower in the HT group than in the sw-IMRT group: 12% versus 78% at 6 months, 3% versus 51% at 12 months, and 0% versus 25% at 24 months. Total parotid mean dose xerostomia at 6, 12, and 24 months. This retrospective series suggests that using HT can better spare the parotid glands while respecting quantitative analysis of normal tissue effects in the clinic (QUANTEC)'s criteria. Copyright © 2013 Wiley Periodicals, Inc.

  5. Parotid Gland Dose in Intensity-Modulated Radiotherapy for Head and Neck Cancer: Is What You Plan What You Get?

    International Nuclear Information System (INIS)

    O'Daniel, Jennifer C.; Garden, Adam S.; Schwartz, David L.; Wang He; Ang, Kian K.; Ahamad, Anesa; Rosenthal, David I.; Morrison, William H.; Asper, Joshua A.; Zhang Lifei; Tung Shihming; Mohan, Radhe; Dong Lei

    2007-01-01

    Purpose: To quantify the differences between planned and delivered parotid gland and target doses, and to assess the benefits of daily bone alignment for head and neck cancer patients treated with intensity-modulated radiotherapy (IMRT). Methods and Materials: Eleven head and neck cancer patients received two CT scans per week with an in-room CT scanner over the course of their radiotherapy. The clinical IMRT plans, designed with 3-mm to 4-mm planning margins, were recalculated on the repeat CT images. The plans were aligned using the actual treatment isocenter marked with radiopaque markers (BB) and bone alignment to the cervical vertebrae to simulate image-guided setup. In-house deformable image registration software was used to map daily dose distributions to the original treatment plan and to calculate a cumulative delivered dose distribution for each patient. Results: Using conventional BB alignment led to increases in the parotid gland mean dose above the planned dose by 5 to 7 Gy in 45% of the patients (median, 3.0 Gy ipsilateral, p = 0.026; median, 1.0 Gy contralateral, p = 0.016). Use of bone alignment led to reductions relative to BB alignment in 91% of patients (median, 2 Gy; range, 0.3-8.3 Gy; 15 of 22 parotids improved). However, the parotid dose from bone alignment was still greater than planned (median, 1.0 Gy, p = 0.007). Neither approach affected tumor dose coverage. Conclusions: With conventional BB alignment, the parotid gland mean dose was significantly increased above the planned mean dose. Using daily bone alignment reduced the parotid dose compared with BB alignment in almost all patients. A 3- to 4-mm planning margin was adequate for tumor dose coverage

  6. The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer

    International Nuclear Information System (INIS)

    Manning, Matthew A.; Wu Quiwen; Cardinale, Robert M.; Mohan, Radhe; Lauve, Andrew D.; Kavanagh, Brian D.; Morris, Monica M.; Schmidt-Ullrich, Rupert K.

    2001-01-01

    Purpose: Intensity-modulated radiotherapy (IMRT) is being evaluated in the management of head-and-neck cancers at several institutions, and a Radiation Therapy Oncology Group study of its utility in parotid sparing is under development. There is an inherent risk that the sharper dose gradients generated by IMRT amplify the potentially detrimental impact of setup uncertainty. The International Commission on Radiation Units and Measurements Report 62 (ICRU-62) defined planning organ-at-risk volume (PRV) to account for positional uncertainties for normal tissues. The purpose of this study is to quantify the dosimetric effect of employing PRV for the parotid gland and to evaluate the use of PRV on normal-tissue sparing in the setting of small clinical setup errors. Methods and Materials: The optimized nine-beam IMRT plans for three head-and-neck cancer patients participating in an institutional review board approved parotid-sparing protocol were used as reference plans. A second optimized plan was generated for each patient by adding a PRV of 5 mm for the contralateral parotid gland. The effect of these additions on the quality of the plans was quantified, in terms of both target coverage and normal-tissue sparing. To test the value of PRV in a worst-case scenario, systematic translational setup uncertainties were simulated by shifting the treatment isocenter 5 mm superiorly, inferiorly, left, right, anteriorly, and posteriorly, without altering optimized beam profiles. At each shifted isocenter, dose distributions were recalculated, producing a total of six shifted plans without PRV and six shifted plans with PRV for each patient. The effect of setup uncertainty on parotid sparing and the value of PRV in compensating for the uncertainty were evaluated. Results: The addition of the PRV and reoptimization did not significantly affect the dose to gross tumor volume, spinal cord, or brainstem. In contrast, without any shift, the PRV did increase parotid sparing and reduce

  7. Effects of radiation on parotid salivary function

    International Nuclear Information System (INIS)

    Marks, J.E.; Davis, C.C.; Gottsman, V.L.

    1981-01-01

    Postoperative electron beam irradiation of patients with parotid cancer has been used regularly at the Mallinckrodt Institute of Radiology to spare the opposite parotid and to preserve salivary function. Only anecdotal reports of amount of radiation required to ablate salivary function exist. To establish a dose-response curve for the human parotid, selective measurements of right and left parotid salivary flow were done for 15 age-matched control patients whose parotids were not irradiated, 17 patients who had both parotids irradiated, and 12 whose parotids were irradiated by unilateral electron beam technique. Point calculations of absorbed dose 1 cm below the surface were done for all 88 parotids and correlated with stimulated parotid salivary flow, pH, and secretory IgA (SIgA). Increasing doses of radiation resulted in progressive reduction of parotid salivary flow, pH, and SIgA. The technique, dosimetry, and clinical application of unilateral electron beam irradiation to spare the opposite parotid will be discussed

  8. Obtaining Normal Tissue Constraints Using Intensity Modulated Radiotherapy (IMRT) in Patients with Oral Cavity, Oropharnygeal, and Laryngeal Carcinoma

    International Nuclear Information System (INIS)

    Skinner, William K.J.; Muse, Evan D.; Yaparpalvi, Ravindra; Guha, Chandan; Garg, Madhur K.; Kalnicki, Shalom

    2009-01-01

    The purpose of this study was to evaluate normal tissue dose constraints while maintaining planning target volume (PTV) prescription without reducing PTV margins. Sixteen patients with oral cavity carcinoma (group I), 27 patients with oropharyngeal carcinoma (group II), and 28 patients with laryngeal carcinoma (group III) were reviewed. Parotid constraints were a mean dose to either parotid < 26 Gy (PP1), 50% of either parotid < 30 Gy (PP2), or 20 cc of total parotid < 20 Gy (PP3). Treatment was intensity modulated radiation therapy (IMRT) with simultaneous integrated boost (SIB). All patients met constraints for cord and brain stem. The mandibular constraints were met in 66%, 29%, and 57% of patients with oral, oropharyngeal, and laryngeal cancers, respectively. Mean dose of 26 Gy (PP1) was achieved in 44%, 41%, and 38% of oral, oropharyngeal, and laryngeal patients. PP2 (parotid constraint of 30 Gy to less than 50% of one parotid) was the easiest to achieve (group I, II, and III: 82%, 76%, and 78%, respectively). PP3 (20 cc of total parotid < 20 Gy) was difficult, and was achieved in 25%, 17%, and 35% of oral, oropharyngeal, and laryngeal patients, respectively. Mean parotid dose of 26 Gy was met 40% of the time. However, a combination of constraints allowed for sparing of the parotid based on different criteria and was met in high numbers. This was accomplished without reducing PTV-parotid overlap. What dose constraint best correlates with subjective and objective functional outcomes remains a focus for future study.

  9. Sparing functional anatomical structures during intensity-modulated radiotherapy: an old problem, a new solution.

    Science.gov (United States)

    Tan, Wenyong; Han, Guang; Wei, Shaozhong; Hu, Desheng

    2014-08-01

    During intensity-modulated radiotherapy, an organ is usually assumed to be functionally homogeneous and, generally, its anatomical and spatial heterogeneity with respect to radiation response are not taken into consideration. However, advances in imaging and radiation techniques as well as an improved understanding of the radiobiological response of organs have raised the possibility of sparing the critical functional structures within various organs at risk during intensity-modulated radiotherapy. Here, we discuss these structures, which include the critical brain structure, or neural nuclei, and the nerve fiber tracts in the CNS, head and neck structures related to radiation-induced salivary and swallowing dysfunction, and functional structures in the heart and lung. We suggest that these structures can be used as potential surrogate organs at risk in order to minimize their radiation dose and/or irradiated volume without compromising the dose coverage of the target volume during radiation treatment.

  10. Reducing Xerostomia After Chemo-IMRT for Head-and-Neck Cancer: Beyond Sparing the Parotid Glands

    Energy Technology Data Exchange (ETDEWEB)

    Little, Michael [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States); Schipper, Matthew [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States); Cancer Center Biostatistics Core, University of Michigan, Ann Arbor, MI (United States); Feng, Felix Y.; Vineberg, Karen [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States); Cornwall, Craig; Murdoch-Kinch, Carol-Anne [Hospital Dentistry, University of Michigan, Ann Arbor, MI (United States); Eisbruch, Avraham, E-mail: eisbruch@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States)

    2012-07-01

    Purpose: To assess whether, in addition to sparing the parotid glands (PGs), xerostomia after chemotherapy plus intensity-modulated radiotherapy (chemo-IMRT) for head-and-neck cancer is affected by reducing the dose to the other salivary glands. Patients and Methods: In a prospective study, 78 patients with Stage III-IV oropharynx/nasopharynx cancer underwent chemo-IMRT, with the aim of sparing the parts of the bilateral PGs, oral cavity (OC) containing the minor salivary glands, and contralateral submandibular gland (SMG) outside the target (when contralateral level I was not a target). Before therapy and periodically for 24 months, validated patient-reported xerostomia questionnaire (XQ) scores and observer-graded xerostomia scores were recorded. Also, the stimulated and unstimulated saliva was measured selectively from each of the PGs and SMGs. The mean OC doses served as surrogates of minor salivary gland dysfunction. Regression models assessed the XQ and observer-graded xerostomia predictors. Results: Statistically significant predictors of the XQ score on univariate analysis included the OC, PG, and SMG mean doses and the baseline XQ score, time since RT, and both stimulated and unstimulated PG saliva flow rates. Similar factors were statistically significant predictors of observer-graded xerostomia. The OC, PG, and SMG mean doses were moderately intercorrelated (r = 0.47-0.55). On multivariate analyses, after adjusting for the PG and SMG doses, the OC mean dose (p < .0001), interval from RT (p < .0001), and stimulated PG saliva (p < .0025) were significant predictors of the XQ scores and the OC mean dose and time for observer-graded xerostomia. Although scatter plots showed no thresholds, an OC mean dose of <40 Gy and contralateral SMG mean dose of <50 Gy were each associated with low patient-reported and observer-rated xerostomia at almost all post-therapy points. Conclusion: The PG, SMG, and OC mean doses were significant predictors of both patient

  11. Reducing Xerostomia After Chemo-IMRT for Head-and-Neck Cancer: Beyond Sparing the Parotid Glands

    International Nuclear Information System (INIS)

    Little, Michael; Schipper, Matthew; Feng, Felix Y.; Vineberg, Karen; Cornwall, Craig; Murdoch-Kinch, Carol-Anne; Eisbruch, Avraham

    2012-01-01

    Purpose: To assess whether, in addition to sparing the parotid glands (PGs), xerostomia after chemotherapy plus intensity-modulated radiotherapy (chemo-IMRT) for head-and-neck cancer is affected by reducing the dose to the other salivary glands. Patients and Methods: In a prospective study, 78 patients with Stage III-IV oropharynx/nasopharynx cancer underwent chemo-IMRT, with the aim of sparing the parts of the bilateral PGs, oral cavity (OC) containing the minor salivary glands, and contralateral submandibular gland (SMG) outside the target (when contralateral level I was not a target). Before therapy and periodically for 24 months, validated patient-reported xerostomia questionnaire (XQ) scores and observer-graded xerostomia scores were recorded. Also, the stimulated and unstimulated saliva was measured selectively from each of the PGs and SMGs. The mean OC doses served as surrogates of minor salivary gland dysfunction. Regression models assessed the XQ and observer-graded xerostomia predictors. Results: Statistically significant predictors of the XQ score on univariate analysis included the OC, PG, and SMG mean doses and the baseline XQ score, time since RT, and both stimulated and unstimulated PG saliva flow rates. Similar factors were statistically significant predictors of observer-graded xerostomia. The OC, PG, and SMG mean doses were moderately intercorrelated (r = 0.47–0.55). On multivariate analyses, after adjusting for the PG and SMG doses, the OC mean dose (p < .0001), interval from RT (p < .0001), and stimulated PG saliva (p < .0025) were significant predictors of the XQ scores and the OC mean dose and time for observer-graded xerostomia. Although scatter plots showed no thresholds, an OC mean dose of <40 Gy and contralateral SMG mean dose of <50 Gy were each associated with low patient-reported and observer-rated xerostomia at almost all post-therapy points. Conclusion: The PG, SMG, and OC mean doses were significant predictors of both patient

  12. Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Katrina, E-mail: Trinabena23@gmail.com; Lenards, Nishele; Holson, Janice

    2016-04-01

    The hippocampus is responsible for memory and cognitive function. An ongoing phase II clinical trial suggests that sparing dose to the hippocampus during whole-brain radiation therapy can help preserve a patient's neurocognitive function. Progressive research and advancements in treatment techniques have made treatment planning more sophisticated but beneficial for patients undergoing treatment. The aim of this study is to evaluate and compare hippocampal sparing whole-brain (HS-WB) radiation therapy treatment planning techniques using volume-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). We randomly selected 3 patients to compare different treatment techniques that could be used for reducing dose to the hippocampal region. We created 2 treatment plans, a VMAT and an IMRT, from each patient's data set and planned on the Eclipse 11.0 treatment planning system (TPS). A total of 6 plans (3 IMRT and 3 VMAT) were created and evaluated for this case study. The physician contoured the hippocampus as per the Radiation Therapy Oncology Group (RTOG) 0933 protocol atlas. The organs at risk (OR) were contoured and evaluated for the plan comparison, which included the spinal cord, optic chiasm, the right and left eyes, lenses, and optic nerves. Both treatment plans produced adequate coverage on the planning target volume (PTV) while significantly reducing dose to the hippocampal region. The VMAT treatment plans produced a more homogenous dose distribution throughout the PTV while decreasing the maximum point dose to the target. However, both treatment techniques demonstrated hippocampal sparing when irradiating the whole brain.

  13. Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study

    International Nuclear Information System (INIS)

    Lee, Katrina; Lenards, Nishele; Holson, Janice

    2016-01-01

    The hippocampus is responsible for memory and cognitive function. An ongoing phase II clinical trial suggests that sparing dose to the hippocampus during whole-brain radiation therapy can help preserve a patient's neurocognitive function. Progressive research and advancements in treatment techniques have made treatment planning more sophisticated but beneficial for patients undergoing treatment. The aim of this study is to evaluate and compare hippocampal sparing whole-brain (HS-WB) radiation therapy treatment planning techniques using volume-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). We randomly selected 3 patients to compare different treatment techniques that could be used for reducing dose to the hippocampal region. We created 2 treatment plans, a VMAT and an IMRT, from each patient's data set and planned on the Eclipse 11.0 treatment planning system (TPS). A total of 6 plans (3 IMRT and 3 VMAT) were created and evaluated for this case study. The physician contoured the hippocampus as per the Radiation Therapy Oncology Group (RTOG) 0933 protocol atlas. The organs at risk (OR) were contoured and evaluated for the plan comparison, which included the spinal cord, optic chiasm, the right and left eyes, lenses, and optic nerves. Both treatment plans produced adequate coverage on the planning target volume (PTV) while significantly reducing dose to the hippocampal region. The VMAT treatment plans produced a more homogenous dose distribution throughout the PTV while decreasing the maximum point dose to the target. However, both treatment techniques demonstrated hippocampal sparing when irradiating the whole brain.

  14. Parotid gland-recovery after radiotherapy in the head and neck region - 36 months follow-up of a prospective clinical study

    Science.gov (United States)

    2011-01-01

    Background The aim of the present study was to evaluate the recovery potential of the parotid glands after using either 3D-conformal-radiotherapy (3D-CRT) or intensity-modulated radiotherapy (IMRT) by sparing one single parotid gland. Methods Between 06/2002 and 10/2008, 117 patients with head and neck cancer were included in this prospective, non-randomised clinical study. All patients were treated with curative intent. Salivary gland function was assessed by measuring stimulated salivary flow at the beginning, during and at the end of radiotherapy as well as 1, 6, 12, 24, and 36 months after treatment. Measurements were converted to flow rates and normalized relative to rates before treatment. Mean doses (Dmean) were calculated from dose-volume histograms based on computed tomographies of the parotid glands. Results Patients were grouped according to the Dmean of the spared parotid gland having the lowest radiation exposure: Group I - Dmean 40 Gy (n = 36). 15/117 (13%) patients received IMRT. By using IMRT as compared to 3D-CRT the Dmean of the spared parotid gland could be significantly reduced (Dmean IMRT vs. 3D-CRT: 21.7 vs. 34.4 Gy, p < 0.001). The relative salivary flow rates (RFSR) as a function of the mean parotid dose after 24 and 36 months was in group I 66% and 74%, in group II 56% and 49%, and in group III 31% and 24%, respectively. Multiple linear regression analyses revealed that the parotid gland dose and the tumor site were the independent determinants 12 and 36 months after the end of RT. Patients of group I and II parotid gland function did recover at 12, 24, and 36 months after the end of RT. Conclusions If a Dmean < 26 Gy for at least one parotid gland can be achieved then this is sufficient to reach complete recovery of pre-RT salivary flow rates. The radiation volume which depends on tumor site did significantly impact on the Dmean of the parotids, and thus on the saliva flow and recovery of parotid gland. PMID:21951317

  15. Parotid gland-recovery after radiotherapy in the head and neck region - 36 months follow-up of a prospective clinical study

    International Nuclear Information System (INIS)

    Hey, Jeremias; Setz, Juergen; Gerlach, Reinhard; Janich, Martin; Hildebrandt, Guido; Vordermark, Dirk; Gernhardt, Christian R; Kuhnt, Thomas

    2011-01-01

    The aim of the present study was to evaluate the recovery potential of the parotid glands after using either 3D-conformal-radiotherapy (3D-CRT) or intensity-modulated radiotherapy (IMRT) by sparing one single parotid gland. Between 06/2002 and 10/2008, 117 patients with head and neck cancer were included in this prospective, non-randomised clinical study. All patients were treated with curative intent. Salivary gland function was assessed by measuring stimulated salivary flow at the beginning, during and at the end of radiotherapy as well as 1, 6, 12, 24, and 36 months after treatment. Measurements were converted to flow rates and normalized relative to rates before treatment. Mean doses (D mean ) were calculated from dose-volume histograms based on computed tomographies of the parotid glands. Patients were grouped according to the D mean of the spared parotid gland having the lowest radiation exposure: Group I - D mean < 26 Gy (n = 36), group II - D mean 26-40 Gy (n = 45), and group III - D mean > 40 Gy (n = 36). 15/117 (13%) patients received IMRT. By using IMRT as compared to 3D-CRT the D mean of the spared parotid gland could be significantly reduced (D mean IMRT vs. 3D-CRT: 21.7 vs. 34.4 Gy, p < 0.001). The relative salivary flow rates (RFSR) as a function of the mean parotid dose after 24 and 36 months was in group I 66% and 74%, in group II 56% and 49%, and in group III 31% and 24%, respectively. Multiple linear regression analyses revealed that the parotid gland dose and the tumor site were the independent determinants 12 and 36 months after the end of RT. Patients of group I and II parotid gland function did recover at 12, 24, and 36 months after the end of RT. If a D mean < 26 Gy for at least one parotid gland can be achieved then this is sufficient to reach complete recovery of pre-RT salivary flow rates. The radiation volume which depends on tumor site did significantly impact on the D mean of the parotids, and thus on the saliva flow and recovery of

  16. Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study.

    Science.gov (United States)

    Lee, Katrina; Lenards, Nishele; Holson, Janice

    2016-01-01

    The hippocampus is responsible for memory and cognitive function. An ongoing phase II clinical trial suggests that sparing dose to the hippocampus during whole-brain radiation therapy can help preserve a patient׳s neurocognitive function. Progressive research and advancements in treatment techniques have made treatment planning more sophisticated but beneficial for patients undergoing treatment. The aim of this study is to evaluate and compare hippocampal sparing whole-brain (HS-WB) radiation therapy treatment planning techniques using volume-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). We randomly selected 3 patients to compare different treatment techniques that could be used for reducing dose to the hippocampal region. We created 2 treatment plans, a VMAT and an IMRT, from each patient׳s data set and planned on the Eclipse 11.0 treatment planning system (TPS). A total of 6 plans (3 IMRT and 3 VMAT) were created and evaluated for this case study. The physician contoured the hippocampus as per the Radiation Therapy Oncology Group (RTOG) 0933 protocol atlas. The organs at risk (OR) were contoured and evaluated for the plan comparison, which included the spinal cord, optic chiasm, the right and left eyes, lenses, and optic nerves. Both treatment plans produced adequate coverage on the planning target volume (PTV) while significantly reducing dose to the hippocampal region. The VMAT treatment plans produced a more homogenous dose distribution throughout the PTV while decreasing the maximum point dose to the target. However, both treatment techniques demonstrated hippocampal sparing when irradiating the whole brain. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  17. Normal liver tissue sparing by intensity-modulated proton stereotactic body radiotherapy for solitary liver tumours

    International Nuclear Information System (INIS)

    Petersen, Joergen B. B.; Hansen, Anders T.; Lassen, Yasmin; Grau, Cai; Hoeyer, Morten; Muren, Ludvig P.

    2011-01-01

    Background. Stereotactic body radiotherapy (SBRT) is often the preferred treatment for the advanced liver tumours which owing to tumour distribution, size and multi-focality are out of range of surgical resection or radiofrequency ablation. However, only a minority of patients with liver tumours may be candidates for conventional SBRT because of the limited radiation tolerance of normal liver, intestine and other normal tissues. Due to the favourable depth-dose characteristics of protons, intensity-modulated proton therapy (IMPT) may be a superior alternative to photon-based SBRT. The purpose of this treatment planning study was therefore to investigate the potential sparing of normal liver by IMPT compared to photon-based intensity-modulated radiotherapy (IMRT) for solitary liver tumours. Material and methods. Ten patients with solitary liver metastasis treated at our institution with multi-field SBRT were retrospectively re-planned with IMRT and proton pencil beam scanning techniques. For the proton plans, two to three coplanar fields were used in contrast to five to six coplanar and non-coplanar photon fields. The same planning objectives were used for both techniques. A risk adapted dose prescription to the PTV surface of 12.5-16.75 Gy x 3 was used. Results. The spared liver volume for IMPT was higher compared to IMRT in all 10 patients. At the highest prescription dose level, the median liver volume receiving less than 15 Gy was 1411 cm 3 for IMPT and 955 cm 3 for IMRT (p D 15 Gy > 700 cm 3 constraint. For the D mean = 15 Gy constraint, nine of 10 cases could be treated at the highest dose level using IMPT whereas with IMRT, only two cases met this constraint at the highest dose level and six at the lowest dose level. Conclusion. A considerable sparing of normal liver tissue can be obtained using proton-based SBRT for solitary liver tumours

  18. Post-nerve-sparing prostatectomy, dose-escalated intensity-modulated radiotherapy: effect on erectile function

    International Nuclear Information System (INIS)

    Bastasch, Michael D.; Teh, Bin S.; Mai, W.-Y.; Carpenter, L. Steven; Lu, Hsin H.; Chiu, J. Kam; Woo, Shiao Y.; Grant, Walter H.; Miles, Brian J.; Kadmon, Dov; Butler, E. Brian

    2002-01-01

    Purpose: The advent of widespread prostate-specific antigen screening has resulted in more younger, potent men being diagnosed with early-stage, organ-confined prostate cancer amenable to definitive surgery. Nerve-sparing prostatectomy is a relatively new surgical advance in the treatment of prostate cancer. Very few data exist on the effect of postoperative radiotherapy (RT) on erectile function after nerve-sparing prostatectomy. They are based on conventional techniques using moderate doses of radiation, 45-54 Gy. Intensity-modulated RT (IMRT) is becoming more widespread because it allows dose escalation with increased sparing of the surrounding normal tissue. We investigated the effect of postprostatectomy, high-dose IMRT on patients' erectile function. Methods and Materials: A review of patient records found 51 patients treated between April 1998 and December 2000 with IMRT after unilateral or bilateral nerve-sparing prostatectomy. The pathologic disease stage in these patients was T2 in 47.4% and T3 in 52.6%. Postoperatively, 4 patients received hormonal ablation consisting of one injection of Lupron Depot (30 mg) 2 months before RT. The median age was 65 years (range 46-77) at the time of RT. The prescribed dose was 64 Gy (range 60-66). The mean dose was 69.6 Gy (range 64.0-72.3). Erectile function was assessed before and after RT by questionnaires. Sexual potency was defined as erectile rigidity adequate for vaginal penetration. Results: Of the 51 patients, 18 (35.3%) maintained their potency and 33 (64.7%) became impotent after nerve-sparing prostatectomy. Patients who underwent bilateral nerve-sparing prostatectomy had higher rates of postoperative potency than did those who underwent unilateral nerve-sparing surgery (72.2% vs. 27.8%; p=0.025). The follow-up for the entire group was 19.5 months. All 18 patients (100%) who were potent postoperatively remained potent after RT. The median follow-up for the 18 potent patients was 27.2 months, significantly

  19. Neural stem cell sparing by linac based intensity modulated stereotactic radiotherapy in intracranial tumors

    International Nuclear Information System (INIS)

    Oehler, Julia; Brachwitz, Tim; Wendt, Thomas G; Banz, Nico; Walther, Mario; Wiezorek, Tilo

    2013-01-01

    Neurocognitive decline observed after radiotherapy (RT) for brain tumors in long time survivors is attributed to radiation exposure of the hippocampus and the subventricular zone (SVZ). The potential of sparing capabilities for both structures by optimized intensity modulated stereotactic radiotherapy (IMSRT) is investigated. Brain tumors were irradiated by stereotactic 3D conformal RT or IMSRT using m3 collimator optimized for PTV and for sparing of the conventional OARs (lens, retina, optic nerve, chiasm, cochlea, brain stem and the medulla oblongata). Retrospectively both hippocampi and SVZ were added to the list of OAR and their dose volume histograms were compared to those from two newly generated IMSRT plans using 7 or 14 beamlets (IMSRT-7, IMSRT-14) dedicated for optimized additional sparing of these structures. Conventional OAR constraints were kept constant. Impact of plan complexity and planning target volume (PTV) topography on sparing of both hippocampi and SVZ, conformity index (CI), the homogeneity index (HI) and quality of coverage (QoC) were analyzed. Limits of agreement were used to compare sparing of stem cell niches with either IMSRT-7 or IMSRT-14. The influence of treatment technique related to the topography ratio between PTV and OARs, realized in group A-D, was assessed by a mixed model. In 47 patients CI (p ≤ 0.003) and HI (p < 0.001) improved by IMSRT-7, IMSRT-14, QoC remained stable (p ≥ 0.50) indicating no compromise in radiotherapy. 90% of normal brain was exposed to a significantly higher dose using IMSRT. IMSRT-7 plans resulted in significantly lower biologically effective doses at all four neural stem cell structures, while contralateral neural stem cells are better spared compared to ipsilateral. A further increase of the number of beamlets (IMSRT-14) did not improve sparing significantly, so IMSRT-7 and IMSRT-14 can be used interchangeable. Patients with tumors contacting neither the subventricular zone nor the cortex benefit

  20. Patient- and therapy-related factors associated with the incidence of xerostomia in nasopharyngeal carcinoma patients receiving parotid-sparing helical tomotherapy.

    Science.gov (United States)

    Lee, Tsair-Fwu; Liou, Ming-Hsiang; Ting, Hui-Min; Chang, Liyun; Lee, Hsiao-Yi; Wan Leung, Stephen; Huang, Chih-Jen; Chao, Pei-Ju

    2015-08-20

    We investigated the incidence of moderate to severe patient-reported xerostomia among nasopharyngeal carcinoma (NPC) patients treated with helical tomotherapy (HT) and identified patient- and therapy-related factors associated with acute and chronic xerostomia toxicity. The least absolute shrinkage and selection operator (LASSO) normal tissue complication probability (NTCP) models were developed using quality-of-life questionnaire datasets from 67 patients with NPC. For acute toxicity, the dosimetric factors of the mean doses to the ipsilateral submandibular gland (Dis) and the contralateral submandibular gland (Dcs) were selected as the first two significant predictors. For chronic toxicity, four predictive factors were selected: age, mean dose to the oral cavity (Doc), education, and T stage. The substantial sparing data can be used to avoid xerostomia toxicity. We suggest that the tolerance values corresponded to a 20% incidence of complications (TD20) for Dis = 39.0 Gy, Dcs = 38.4 Gy, and Doc = 32.5 Gy, respectively, when mean doses to the parotid glands met the QUANTEC 25 Gy sparing guidelines. To avoid patient-reported xerostomia toxicity, the mean doses to the parotid gland, submandibular gland, and oral cavity have to meet the sparing tolerance, although there is also a need to take inherent patient characteristics into consideration.

  1. Factors influencing bowel sparing in intensity modulated whole pelvic radiotherapy for gynaecological malignancies

    International Nuclear Information System (INIS)

    Georg, Petra; Georg, Dietmar; Hillbrand, Martin; Kirisits, Christian; Poetter, Richard

    2006-01-01

    Background and purpose: To evaluate the influence of uterus and bladder size on large and small bowel sparing with intensity modulated whole pelvic radiotherapy (IM-WPRT) in gynecologic patients. Patients and methods: Twenty patients were selected; 10 women with cervical cancer treated with definitive radiotherapy (group 'DEF') and 10 endometrial cancer patients treated postoperatively (group 'POST'). Bladder, rectal wall, small (SB) and large bowel (LB) were delineated as organs at risk. A conformal four field technique and a seven field IMRT plan (prescription dose 50.4 Gy) were compared in terms of DVH and various target parameters. Results: At doses between 40 and 50.4 Gy statistically significant improvements (P<0.05) were observed for IM-WPRT for irradiated volume of rectal wall and bladder. In both patient groups, with IMRT the average irradiated volume of SB was reduced by a factor of 6 at 50.4 Gy. This ratio was 2 for LB. In the DEF group the effect of SB-sparing with IMRT correlated with bladder size (correlation coefficient 0.70) while it did not correlate in the postoperative group. The effect of LB-sparing decreased with increasing bladder size in both groups but the impact of IMRT was larger for postoperative patients. Conclusions: IMRT significantly reduced the absolute volume of rectal wall, bladder and bowel irradiated at the prescribed dose level in gynaecologic patients. Main differences between POST and DEF patients receiving IM-WPRT were absolute volumes of LB irradiated to doses between 35 and 50 Gy, suggesting an impact of intact uterus on LB volume in the pelvis. POST patients seem to benefit most from elective nodal IMRT. Bladder filling is an important co-factor influencing the benefit of IMRT with respect to OAR sparing

  2. Effect of Cisplatin on Parotid Gland Function in Concomitant Radiochemotherapy

    International Nuclear Information System (INIS)

    Hey, Jeremias; Setz, Juergen; Gerlach, Reinhard; Vordermark, Dirk; Gernhardt, Christian R.; Kuhnt, Thomas

    2009-01-01

    Purpose: To determine the influence of concomitant radiochemotherapy with cisplatin on parotid gland tissue complication probability. Methods and Materials: Patients treated with either radiotherapy (n = 61) or concomitant radiochemotherapy with cisplatin (n = 36) for head-and-neck cancer were prospectively evaluated. The dose and volume distributions of the parotid glands were noted in dose-volume histograms. Stimulated salivary flow rates were measured before, during the 2nd and 6th weeks and at 4 weeks and 6 months after the treatment. The data were fit using the normal tissue complication probability model of Lyman. Complication was defined as a reduction of the salivary flow rate to less than 25% of the pretreatment flow rate. Results: The normal tissue complication probability model parameter TD 50 (the dose leading to a complication probability of 50%) was found to be 32.2 Gy at 4 weeks and 32.1 Gy at 6 months for concomitant radiochemotherapy and 41.1 Gy at 4 weeks and 39.6 Gy at 6 months for radiotherapy. The tolerated dose for concomitant radiochemotherapy was at least 7 to 8 Gy lower than for radiotherapy alone at TD 50 . Conclusions: In this study, the concomitant radiochemotherapy tended to cause a higher probability of parotid gland tissue damage. Advanced radiotherapy planning approaches such as intensity-modulated radiotherapy may be partiticularly important for parotid sparing in radiochemotherapy because of cisplatin-related increased radiosensitivity of glands.

  3. Rules of parotid gland dose variations and shift during intensity modulated radiation therapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Wang, Wei; Yang, Haihua; Mi, Yucheng; Hu, Wei; Ding, Weijun; Xie, Youyou; Cai, Yujie; Chen, Xiaofeng

    2015-01-01

    To determine the position and dose delivery changes rules of parotid gland (PG) during the course of intensity modulated radiation therapy (IMRT) in nasopharyngeal carcinoma patients (NPC). One hundred and forty one competed tomography (CT) images from 47 NPC patients (three images for each patient were acquired before treatment, at the 15th and 25th fraction during the treatment) who underwent radical IMRT were selected for this study. A total of 70-76Gy at 2.12–2.3 Gy/fraction/d was given to the GTVnx in 33 fractions. The distances between the lateral/medial aspects of PG and midline (DLM and DMM) at the level of odontoid process were measured. The dose differences between plan and actual delivery were calculated. The volume reductions of PGs between fractions 15 and 25 were larger than those in the first 15 fractions (4.68 ± 3.23 cc vs. 2.46 ± 4.55 cc for the right PG and 5.96 ± 2.99 cc vs. 2.06 ± 2.99 cc for the left PG). However, the percentage of gland volume receiving ≥30 Gy (V30) of bilateral PGs decreased more significantly in the first 15 fractions than that between fractions 15 and 25 (5.61 ± 16.04% vs. 1.14 ± 21.54% for the right PG and 6.87 ± 15.58% vs. 0.81 ± 15.94% for the left PG). The gross tumor volume of the nasopharynx (GTVnx) decreased more significantly in the first 15 fractions than that between the 15th and 25th fraction (8.23 ± 13.61 cc vs. 3.30 ± 8.09 cc). The DMM of ipsilateral PGs reduced in the first 15 fractions (0.80 ± 2.96 mm) but increased between fraction 15 and 25 (−2.19 ± 3.96 mm). While ipsilateral PG shifted into target volume but shifted out target volume between fraction 15 and 25. Parotid glands V30 was correlated with GTVnx, GTVnx reduction and DMM reduction (p < 0.01). Our results indicate that the reduction of GTVnx leads to the positional change of the parotid gland, which results in more significant dose change of the parotid gland in the first 15 fractions than that between fraction 15 and 25

  4. Split-field vs extended-field intensity-modulated radiation therapy plans for oropharyngeal cancer: Which spares the larynx? Which spares the thyroid?

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Yao; Chen, Josephine [Department of Radiation Oncology, University of California, San Francisco, San Francisco, CA (United States); Leary, Celeste I. [Department of Radiation Medicine, Oregon Health Sciences University, Portland, OR (United States); Shugard, Erin [Department of Radiation Oncology, University of California, San Francisco, San Francisco, CA (United States); Yom, Sue S., E-mail: yoms@radonc.ucsf.edu [Department of Radiation Oncology, University of California, San Francisco, San Francisco, CA (United States); Department of Otolaryngology—Head and Neck Surgery, University of California, San Francisco, San Francisco, CA (United States)

    2016-07-01

    Radiation of the low neck can be accomplished using split-field intensity-modulated radiation therapy (sf-IMRT) or extended-field intensity-modulated radiation therapy (ef-IMRT). We evaluated the effect of these treatment choices on target coverage and thyroid and larynx doses. Using data from 14 patients with cancers of the oropharynx, we compared the following 3 strategies for radiating the low neck: (1) extended-field IMRT, (2) traditional split-field IMRT with an initial cord-junction block to 40 Gy, followed by a full-cord block to 50 Gy, and (3) split-field IMRT with a full-cord block to 50 Gy. Patients were planned using each of these 3 techniques. To facilitate comparison, extended-field plans were normalized to deliver 50 Gy to 95% of the neck volume. Target coverage was assessed using the dose to 95% of the neck volume (D{sub 95}). Mean thyroid and larynx doses were computed. Extended-field IMRT was used as the reference arm; the mean larynx dose was 25.7 ± 7.4 Gy, and the mean thyroid dose was 28.6 ± 2.4 Gy. Split-field IMRT with 2-step blocking reduced laryngeal dose (mean larynx dose 15.2 ± 5.1 Gy) at the cost of a moderate reduction in target coverage (D{sub 95} 41.4 ± 14 Gy) and much higher thyroid dose (mean thyroid dose 44.7 ± 3.7 Gy). Split-field IMRT with initial full-cord block resulted in greater laryngeal sparing (mean larynx dose 14.2 ± 5.1 Gy) and only a moderately higher thyroid dose (mean thyroid dose 31 ± 8 Gy) but resulted in a significant reduction in target coverage (D{sub 95} 34.4 ± 15 Gy). Extended-field IMRT comprehensively covers the low neck and achieves acceptable thyroid and laryngeal sparing. Split-field IMRT with a full-cord block reduces laryngeal doses to less than 20 Gy and spares the thyroid, at the cost of substantially reduced coverage of the low neck. Traditional 2-step split-field IMRT similarly reduces the laryngeal dose but also reduces low-neck coverage and delivers very high doses to the thyroid.

  5. SU-E-T-808: Volumetric Modulated Arc Radiotherapy Vs. Intensity-Modulated Radiotherapy for Early-Stage Nasopharyngeal Carcinoma: A Dosimetric Study

    Energy Technology Data Exchange (ETDEWEB)

    Lu, J-Y; Huang, B-T; Zhang, W-Z [Cancer Hospital of Shantou University Medical College, Shantou, Guangdong (China)

    2015-06-15

    Purpose: To compare volumetric modulated arc radiotherapy (VMAT) technique with fixed-gantry intensity-modulated radiotherapy (IMRT) technique for early-stage nasopharyngeal carcinoma. Methods: CT datasets of ten patients with early-stage nasopharyngeal carcinoma were included. Dual-arc VMAT and nine-field IMRT plans were generated for each case, and were then compared in terms of planning-target-volume (PTV) coverage, conformity index (CI) and homogeneity index (HI), as well as organ-at-risk (OAR) sparing, planning time, monitor units (MUs) and delivery time. Results: Compared with the IMRT plans, the VMAT plans provided comparable HI and CI of PTVnx (PTV of primary tumor of nasopharynx), superior CI and inferior HI of PTVnd (PTV of lymph nodes), as well as superior CI and comparable HI of PTV60 (high-risk PTV). The VMAT plans provided better sparing of the spinal cord, oral cavity and normal tissue, but inferior sparing of the brainstem planning OAR volume (PRV), larynx and parotids, as well as comparable sparing of the spinal cord PRV, brainstem, lenses, optic nerves, optic chiasm. Moreover, the average planning time (181.6 ± 36.0 min) for the VMAT plans was 171% more than that of the IMRT plans (68.1 ± 7.6 min). The MUs of the VMAT plans (609 ± 43) were 70% lower than those of the IMRT plans (2071 ± 262), while the average delivery time (2.2 ± 0.1 min) was 66% less than that of the IMRT plans (6.6 ± 0.4 min). Conclusion: Compared with the IMRT technique, the VMAT technique can achieve similar or slightly superior target dose distribution, with no significant advantages on OAR sparing, and it can achieve significant reductions of MUs and delivery time.

  6. SU-E-T-808: Volumetric Modulated Arc Radiotherapy Vs. Intensity-Modulated Radiotherapy for Early-Stage Nasopharyngeal Carcinoma: A Dosimetric Study

    International Nuclear Information System (INIS)

    Lu, J-Y; Huang, B-T; Zhang, W-Z

    2015-01-01

    Purpose: To compare volumetric modulated arc radiotherapy (VMAT) technique with fixed-gantry intensity-modulated radiotherapy (IMRT) technique for early-stage nasopharyngeal carcinoma. Methods: CT datasets of ten patients with early-stage nasopharyngeal carcinoma were included. Dual-arc VMAT and nine-field IMRT plans were generated for each case, and were then compared in terms of planning-target-volume (PTV) coverage, conformity index (CI) and homogeneity index (HI), as well as organ-at-risk (OAR) sparing, planning time, monitor units (MUs) and delivery time. Results: Compared with the IMRT plans, the VMAT plans provided comparable HI and CI of PTVnx (PTV of primary tumor of nasopharynx), superior CI and inferior HI of PTVnd (PTV of lymph nodes), as well as superior CI and comparable HI of PTV60 (high-risk PTV). The VMAT plans provided better sparing of the spinal cord, oral cavity and normal tissue, but inferior sparing of the brainstem planning OAR volume (PRV), larynx and parotids, as well as comparable sparing of the spinal cord PRV, brainstem, lenses, optic nerves, optic chiasm. Moreover, the average planning time (181.6 ± 36.0 min) for the VMAT plans was 171% more than that of the IMRT plans (68.1 ± 7.6 min). The MUs of the VMAT plans (609 ± 43) were 70% lower than those of the IMRT plans (2071 ± 262), while the average delivery time (2.2 ± 0.1 min) was 66% less than that of the IMRT plans (6.6 ± 0.4 min). Conclusion: Compared with the IMRT technique, the VMAT technique can achieve similar or slightly superior target dose distribution, with no significant advantages on OAR sparing, and it can achieve significant reductions of MUs and delivery time

  7. Bone marrow sparing in intensity modulated proton therapy for cervical cancer: Efficacy and robustness under range and setup uncertainties

    International Nuclear Information System (INIS)

    Dinges, Eric; Felderman, Nicole; McGuire, Sarah; Gross, Brandie; Bhatia, Sudershan; Mott, Sarah; Buatti, John; Wang, Dongxu

    2015-01-01

    Background and purpose: This study evaluates the potential efficacy and robustness of functional bone marrow sparing (BMS) using intensity-modulated proton therapy (IMPT) for cervical cancer, with the goal of reducing hematologic toxicity. Material and methods: IMPT plans with prescription dose of 45 Gy were generated for ten patients who have received BMS intensity-modulated X-ray therapy (IMRT). Functional bone marrow was identified by 18 F-flourothymidine positron emission tomography. IMPT plans were designed to minimize the volume of functional bone marrow receiving 5–40 Gy while maintaining similar target coverage and healthy organ sparing as IMRT. IMPT robustness was analyzed with ±3% range uncertainty errors and/or ±3 mm translational setup errors in all three principal dimensions. Results: In the static scenario, the median dose volume reductions for functional bone marrow by IMPT were: 32% for V 5Gy , 47% for V 10Gy , 54% for V 20Gy , and 57% for V 40Gy , all with p < 0.01 compared to IMRT. With assumed errors, even the worst-case reductions by IMPT were: 23% for V 5Gy , 37% for V 10Gy , 41% for V 20Gy , and 39% for V 40Gy , all with p < 0.01. Conclusions: The potential sparing of functional bone marrow by IMPT for cervical cancer is significant and robust under realistic systematic range uncertainties and clinically relevant setup errors

  8. Bone Marrow Sparing in Intensity Modulated Proton Therapy for Cervical Cancer: Efficacy and Robustness under Range and Setup Uncertainties

    Science.gov (United States)

    Dinges, Eric; Felderman, Nicole; McGuire, Sarah; Gross, Brandie; Bhatia, Sudershan; Mott, Sarah; Buatti, John; Wang, Dongxu

    2015-01-01

    Background and Purpose This study evaluates the potential efficacy and robustness of functional bone marrow sparing (BMS) using intensity-modulated proton therapy (IMPT) for cervical cancer, with the goal of reducing hematologic toxicity. Material and Methods IMPT plans with prescription dose of 45 Gy were generated for ten patients who have received BMS intensity-modulated x-ray therapy (IMRT). Functional bone marrow was identified by 18F-flourothymidine positron emission tomography. IMPT plans were designed to minimize the volume of functional bone marrow receiving 5–40 Gy while maintaining similar target coverage and healthy organ sparing as IMRT. IMPT robustness was analyzed with ±3% range uncertainty errors and/or ±3mm translational setup errors in all three principal dimensions. Results In the static scenario, the median dose volume reductions for functional bone marrow by IMPT were: 32% for V5GY, 47% for V10Gy, 54% for V20Gy, and 57% for V40Gy, all with p<0.01 compared to IMRT. With assumed errors, even the worst-case reductions by IMPT were: 23% for V5Gy, 37% for V10Gy, 41% for V20Gy, and 39% for V40Gy, all with p<0.01. Conclusions The potential sparing of functional bone marrow by IMPT for cervical cancer is significant and robust under realistic systematic range uncertainties and clinically relevant setup errors. PMID:25981130

  9. Impact of head and neck cancer adaptive radiotherapy to spare the parotid glands and decrease the risk of xerostomia.

    Science.gov (United States)

    Castelli, Joel; Simon, Antoine; Louvel, Guillaume; Henry, Olivier; Chajon, Enrique; Nassef, Mohamed; Haigron, Pascal; Cazoulat, Guillaume; Ospina, Juan David; Jegoux, Franck; Benezery, Karen; de Crevoisier, Renaud

    2015-01-09

    Large anatomical variations occur during the course of intensity-modulated radiation therapy (IMRT) for locally advanced head and neck cancer (LAHNC). The risks are therefore a parotid glands (PG) overdose and a xerostomia increase. The purposes of the study were to estimate: - the PG overdose and the xerostomia risk increase during a "standard" IMRT (IMRTstd); - the benefits of an adaptive IMRT (ART) with weekly replanning to spare the PGs and limit the risk of xerostomia. Fifteen patients received radical IMRT (70 Gy) for LAHNC. Weekly CTs were used to estimate the dose distributions delivered during the treatment, corresponding either to the initial planning (IMRTstd) or to weekly replanning (ART). PGs dose were recalculated at the fraction, from the weekly CTs. PG cumulated doses were then estimated using deformable image registration. The following PG doses were compared: pre-treatment planned dose, per-treatment IMRTstd and ART. The corresponding estimated risks of xerostomia were also compared. Correlations between anatomical markers and dose differences were searched. Compared to the initial planning, a PG overdose was observed during IMRTstd for 59% of the PGs, with an average increase of 3.7 Gy (10.0 Gy maximum) for the mean dose, and of 8.2% (23.9% maximum) for the risk of xerostomia. Compared to the initial planning, weekly replanning reduced the PG mean dose for all the patients (pxerostomia by 11% (pxerostomia risk.

  10. Prospective longitudinal assessment of parotid gland function using dynamic quantitative pertechnate scintigraphy and estimation of dose–response relationship of parotid-sparing radiotherapy in head-neck cancers

    International Nuclear Information System (INIS)

    Gupta, Tejpal; Hotwani, Chandni; Kannan, Sadhana; Master, Zubin; Rangarajan, Venkatesh; Murthy, Vedang; Budrukkar, Ashwini; Ghosh-Laskar, Sarbani; Agarwal, Jai Prakash

    2015-01-01

    To estimate dose–response relationship using dynamic quantitative 99m Tc-pertechnate scintigraphy in head-neck cancer patients treated with parotid-sparing conformal radiotherapy. Dynamic quantitative pertechnate salivary scintigraphy was performed pre-treatment and subsequently periodically after definitive radiotherapy. Reduction in salivary function following radiotherapy was quantified by salivary excretion fraction (SEF) ratios. Dose–response curves were modeled using standardized methodology to calculate tolerance dose 50 (TD50) for parotid glands. Salivary gland function was significantly affected by radiotherapy with maximal decrease in SEF ratios at 3-months, with moderate functional recovery over time. There was significant inverse correlation between SEF ratios and mean parotid doses at 3-months (r = −0.589, p < 0.001); 12-months (r = −0.554, p < 0.001); 24-months (r = −0.371, p = 0.002); and 36-months (r = −0.350, p = 0.005) respectively. Using a post-treatment SEF ratio <45% as the scintigraphic criteria to define severe salivary toxicity, the estimated TD50 value with its 95% confidence interval (95% CI) for the parotid gland was 35.1Gy (23.6-42.6Gy), 41.3Gy (34.6-48.8Gy), 55.9Gy (47.4-70.0Gy) and 64.3Gy (55.8-70.0Gy) at 3, 12, 24, and 36-months respectively. There is consistent decline in parotid function even after conformal radiotherapy with moderate recovery over time. Dynamic quantitative pertechnate scintigraphy is a simple, reproducible, and minimally invasive test of major salivary gland function. The online version of this article (doi:10.1186/s13014-015-0371-2) contains supplementary material, which is available to authorized users

  11. Parotid gland-sparing 3-dimensional conformal radiotherapy results in less severe dry mouth in nasopharyngeal cancer patients: A dosimetric and clinical comparison with conventional radiotherapy

    International Nuclear Information System (INIS)

    Jen, Y.-M.; Shih Rompin; Lin, Y.-S.; Su, W.-F.; Ku, C.-H.; Chang, C.-S.; Shueng, P.-W.; Hwang, J.-M.; Liu, D.-W.; Chao, H.-L.; Lin, H.-Y.; Chang, L.-P.; Shum, W.-Y.; Lin, C.-S.

    2005-01-01

    Background and purpose: This study examined the efficacy of parotid gland sparing of three-dimensional conformal radiotherapy (3DCRT) compared with conventional radiotherapy for NPC patients. Both the dose given to the parotids and clinical assessment of dry mouth were conducted. Materials and methods: Dry mouth was assessed for 108 patients treated with conventional technique and 72 treated with 3DCRT. Dose analysis was performed in 48 patients of the 3DCRT group. A dose of 70 Gy was given to the midplane in conventional radiotherapy and to 90% isodose volume in 3DCRT. Prognostic factors affecting the severity of dry mouth were analyzed using Generalized Estimating Equation (GEE). Results: In the 3DCRT group about 50% of the patients' parotid glands received less than 25 Gy. Parallel analysis of dry mouth shows a significant decrease in the incidence of severe xerostomia after 3DCRT. The proportion of patients without dry mouth was also significantly higher in the 3DCRT group than the conventional group at 1-3 years after completion of radiotherapy. Although 3DCRT delivered a higher dose to the tumor, it spared the parotid gland significantly better than the conventional treatment. Late toxicities were mostly similar between the 2 groups while local control in T4 patients and survival were improved for 3DCRT. Conclusion: Dosimetrically and clinically 3DCRT is better than conventional technique regarding parotid gland protection

  12. Dosimetric complication probability and acoustic analysis of vocal cord region in oropharyngeal carcinoma treated with voice-sparing intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Jain, S.; Gupta, T.; Agarwal, J.P.; Baccher, G.; Shrivastava, S.K.; Reenadevi; Master, J.

    2008-01-01

    Radiation to larynx has long been associated with speech and voice dysfunction. The objective is to study dosimetric parameters and complication probability of vocal cord region (VCR) and the effect of voice-sparing (VS) in the patients treated with intensity modulated radiotherapy (IMRT). The secondary objective is to describe the post-radiation acoustic voice characteristics and correlate them with the dosimetric parameters. (author)

  13. Simple Carotid-Sparing Intensity-Modulated Radiotherapy Technique and Preliminary Experience for T1-2 Glottic Cancer

    International Nuclear Information System (INIS)

    Rosenthal, David I.; Fuller, Clifton D.; Barker, Jerry L.; Mason, Bryan M.S.; Garcia, John A. C.; Lewin, Jan S.; Holsinger, F. Christopher; Stasney, C. Richard; Frank, Steven J.; Schwartz, David L.; Morrison, William H.; Garden, Adam S.; Ang, K. Kian

    2010-01-01

    Purpose: To investigate the dosimetry and feasibility of carotid-sparing intensity-modulated radiotherapy (IMRT) for early glottic cancer and to report preliminary clinical experience. Methods and Materials: Digital Imaging and Communications in Medicine radiotherapy (DICOM-RT) datasets from 6 T1-2 conventionally treated glottic cancer patients were used to create both conventional IMRT plans. We developed a simplified IMRT planning algorithm with three fields and limited segments. Conventional and IMRT plans were compared using generalized equivalent uniform dose and dose-volume parameters for in-field carotid arteries, target volumes, and organs at risk. We have treated 11 patients with this simplified IMRT technique. Results: Intensity-modulated radiotherapy consistently reduced radiation dose to the carotid arteries (p < 0.05) while maintaining the clinical target volume coverage. With conventional planning, median carotid V35, V50, and V63 were 100%, 100%, and 69.0%, respectively. With IMRT planning these decreased to 2%, 0%, and 0%, respectively (p < 0.01). Radiation planning and treatment times were similar for conventional radiotherapy and IMRT. Treatment results have been excellent thus far. Conclusions: Intensity-modulated radiotherapy significantly reduced unnecessary radiation dose to the carotid arteries compared with conventional lateral fields while maintaining clinical target volume coverage. Further experience and longer follow-up will be required to demonstrate outcomes for cancer control and carotid artery effects.

  14. Skin-Sparing Radiation Using Intensity-Modulated Radiotherapy After Conservative Surgery in Early-Stage Breast Cancer: A Planning Study

    International Nuclear Information System (INIS)

    Saibishkumar, Elantholi P.; MacKenzie, Marc A.; Severin, Diane; Mihai, Alina; Hanson, John M.Sc.; Daly, Helene; Fallone, Gino; Parliament, Matthew B.; Abdulkarim, Bassam S.

    2008-01-01

    Purpose: To evaluate the feasibility of skin-sparing by configuring it as an organ-at-risk (OAR) while delivering whole-breast intensity-modulated radiotherapy (IMRT) in early breast cancer. Methods and Materials: Archival computed tomography scan images of 14 left-sided early-breast tumor patients who had undergone lumpectomy were selected for this study. Skin was contoured as a 4- to 5-mm strip extending from the patient outline to anterior margin of the breast planning target volume (PTV). Two IMRT plans were generated by the helical tomotherapy approach to deliver 50 Gy in 25 fractions to the breast alone: one with skin dose constraints (skin-sparing plan) and the other without (non-skin-sparing plan). Comparison of the plans was done using a two-sided paired Student t test. Results: The mean skin dose and volume of skin receiving 50 Gy were significantly less with the skin-sparing plan compared with non-skin-sparing plan (42.3 Gy vs. 47.7 Gy and 12.2% vs. 57.8% respectively; p < 0.001). The reduction in skin dose was confirmed by TLD measurements in anthropomorphic phantom using the same plans. Dose-volume analyses for other OARs were similar in both plans. Conclusions: By configuring the skin as an OAR, it is possible to achieve skin dose reduction while delivering whole-breast IMRT without compromising dose profiles to PTV and OARs

  15. The effect of concomitant chemotherapy on parotid gland function following head and neck IMRT

    International Nuclear Information System (INIS)

    Miah, Aisha B.; Gulliford, Sarah L.; Bhide, Shreerang A.; Zaidi, Shane H.; Newbold, Kate L.; Harrington, Kevin J.; Nutting, Christopher M.

    2013-01-01

    Purpose: To determine whether concomitant chemotherapy increases the incidence of high grade xerostomia following parotid-sparing intensity-modulated radiotherapy (IMRT) in patients with locally advanced head and neck squamous cell cancer. Materials and methods: The incidence of high grade (⩾G2) acute (CTCAEv3.0) and late (LENTSOMA and RTOG) xerostomia was compared between patients treated with either IMRT or concomitant chemo-IMRT (c-IMRT) in 2 prospective studies. Parotid gland mean tolerance doses (D 50 ) were reported using non-linear logistic regression analysis. Results: Thirty-six patients received IMRT alone and 60 patients received c-IMRT. Patients received 65 Gy in 30 daily fractions to the primary site and involved nodal groups and 54 Gy in 30 fractions to elective nodal groups, mean doses to the parotid glands were comparable. Concomitant cisplatin 100 mg/m 2 was administered on days 1 and 29 of IMRT. The incidence of ⩾G2 subjective xerostomia was similar in both groups; acute-64.7% (IMRT) versus 60.3% (c-IMRT), p = 0.83; late-43% (IMRT) versus 34% (c-IMRT), p = 0.51. Recovery of parotid salivary flow at 1 year was higher with IMRT (64% vs 50%), but not statistically significant (p = 0.15). D 50 for absence of parotid saliva flow at 1 year was 23.2 Gy (95% CI: 17.7–28.7) for IMRT and 21.1 Gy (11.8–30.3) for c-IMRT. Conclusion: Concomitant c-IMRT does not increase the incidence of acute or late xerostomia relative to IMRT alone

  16. The effect of concomitant chemotherapy on parotid gland function following head and neck IMRT.

    Science.gov (United States)

    Miah, Aisha B; Gulliford, Sarah L; Bhide, Shreerang A; Zaidi, Shane H; Newbold, Kate L; Harrington, Kevin J; Nutting, Christopher M

    2013-03-01

    To determine whether concomitant chemotherapy increases the incidence of high grade xerostomia following parotid-sparing intensity-modulated radiotherapy (IMRT) in patients with locally advanced head and neck squamous cell cancer. The incidence of high grade (≥G2) acute (CTCAEv3.0) and late (LENTSOMA and RTOG) xerostomia was compared between patients treated with either IMRT or concomitant chemo-IMRT (c-IMRT) in 2 prospective studies. Parotid gland mean tolerance doses (D₅₀) were reported using non-linear logistic regression analysis. Thirty-six patients received IMRT alone and 60 patients received c-IMRT. Patients received 65 Gy in 30 daily fractions to the primary site and involved nodal groups and 54 Gy in 30 fractions to elective nodal groups, mean doses to the parotid glands were comparable. Concomitant cisplatin 100mg/m(2) was administered on days 1 and 29 of IMRT. The incidence of ≥G2 subjective xerostomia was similar in both groups; acute-64.7% (IMRT) versus 60.3% (c-IMRT), p=0.83; late-43% (IMRT) versus 34% (c-IMRT), p=0.51. Recovery of parotid salivary flow at 1 year was higher with IMRT (64% vs 50%), but not statistically significant (p=0.15). D₅₀ for absence of parotid saliva flow at 1 year was 23.2 Gy (95% CI: 17.7-28.7) for IMRT and 21.1 Gy (11.8-30.3) for c-IMRT. Concomitant c-IMRT does not increase the incidence of acute or late xerostomia relative to IMRT alone. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Prospective Study of Functional Bone Marrow-Sparing Intensity Modulated Radiation Therapy With Concurrent Chemotherapy for Pelvic Malignancies

    International Nuclear Information System (INIS)

    Liang Yun; Bydder, Mark; Yashar, Catheryn M.; Rose, Brent S.; Cornell, Mariel; Hoh, Carl K.; Lawson, Joshua D.; Einck, John; Saenz, Cheryl; Fanta, Paul; Mundt, Arno J.; Bydder, Graeme M.

    2013-01-01

    Purpose: To test the hypothesis that intensity modulated radiation therapy (IMRT) can reduce radiation dose to functional bone marrow (BM) in patients with pelvic malignancies (phase IA) and estimate the clinical feasibility and acute toxicity associated with this technique (phase IB). Methods and Materials: We enrolled 31 subjects (19 with gynecologic cancer and 12 with anal cancer) in an institutional review board-approved prospective trial (6 in the pilot study, 10 in phase IA, and 15 in phase IB). The mean age was 52 years; 8 of 31 patients (26%) were men. Twenty-one subjects completed 18 F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) simulation and magnetic resonance imaging by use of quantitative IDEAL (IDEAL IQ; GE Healthcare, Waukesha, WI). The PET/CT and IDEAL IQ were registered, and BM subvolumes were segmented above the mean standardized uptake value and below the mean fat fraction within the pelvis and lumbar spine; their intersection was designated as functional BM for IMRT planning. Functional BM-sparing vs total BM-sparing IMRT plans were compared in 12 subjects; 10 were treated with functional BM-sparing pelvic IMRT per protocol. Results: In gynecologic cancer patients, the mean functional BM V 10 (volume receiving ≥10 Gy) and V 20 (volume receiving ≥20 Gy) were 85% vs 94% (P 18 F-fluorodeoxyglucose-PET/CT and IDEAL IQ. The efficacy of BM-sparing IMRT is being tested in a phase II trial.

  18. SU-E-T-449: Hippocampal Sparing Radiotherapy Using Intensity Modulated Radiotherapy and Volumetric Modulated Arc Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Moon, S [Korea University, Seoul (Korea, Republic of); Kyung Hee University Hospital at Gangdong, Gangdong-gu (Korea, Republic of); Kim, D; Chung, W [Kyung Hee University Hospital at Gangdong, Gangdong-gu (Korea, Republic of); Yoon, M [Korea University, Seoul (Korea, Republic of)

    2015-06-15

    Purpose: The hippocampus sparing during the cranial irradiation has become interesting because it may mitigate radiation-induced neurocognitive toxicity. Herein we report our preliminary study for sparing the hippocampus with and without tilling condition for patient with brain metastases. Methods: Ten patients previously treated with whole brain were reviewed. Five patients tilted the head to around 30 degrees and others were treated without tilting. Treatment plans of linear accelerator (Linac)-based volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT) were generated for prescription dose of 30 Gy in 15 fractions. Hippocampal avoidance regions were created with 5-mm volumetric expansion around the hippocampus. Whole brain, hippocampus and hippocampal avoidance volume were 1372cm3, 6cm3 and 30cm3 and hippocampal avoidance volume was 2.2% of the whole brain planned target volume in average. Organs at risk (OARs) are hippocampus, eyes, lens, and cochleae. Coverage index (CVI), conformity index (CI), homogeneity index (HI) and mean dose to OARs were used to compare dose characteristic of tilted and non-tilted cases. Results: In IMRT, when CI, CVI and HI of whole brain were 0.88, 0.09 and 0.98 in both tilted and non-tilted cases, absorbed dose of hippocampal avoidance volume in tilted cases were 10% lower than non-tilted cases. Doses in other OARs such as eyes, lens, and cochleae were also decreased about 20% when tilting the head. When CI, HI and CVI in VMAT were 0.9, 0.08 and 0.99, the dose-decreased ratio of OARs in both with and without tilting cases were almost the same with IMRT. But absolute dose of hippocampal avoidance volume in VMAT was 30% lower than IMRT. Conclusion: This study confirms that dose to hippocampus decreases if patients tilt the head. When treating the whole brain with head tilted, patients can acquire the same successful treatment Result and also preserve their valuable memory.

  19. Urethra sparing - potential of combined Nickel-Titanium stent and intensity modulated radiation therapy in prostate cancer.

    Science.gov (United States)

    Thomsen, Jakob Borup; Arp, Dennis Tideman; Carl, Jesper

    2012-05-01

    To investigate a novel method for sparing urethra in external beam radiotherapy of prostate cancer and to evaluate the efficacy of such a treatment in terms of tumour control using a mathematical model. This theoretical study includes 20 patients previously treated for prostate cancer using external beam radiotherapy. All patients had a Nickel-Titanium (Ni-Ti) stent inserted into the prostate part of urethra. The stent has been used during the treatment course as an internal marker for patient positioning prior to treatment. In this study the stent is used for delineating urethra while intensity modulated radiotherapy was used for lowering dose to urethra. Evaluation of the dose plans were performed using a tumour control probability model based on the concept of uniform equivalent dose. The feasibility of the urethra dose reduction method is validated and a reduction of about 17% is shown to be possible. Calculations suggest a nearly preserved tumour control probability. A new concept for urethra dose reduction is presented. The method relies on the use of a Ni-Ti stent as a fiducial marker combined with intensity modulated radiotherapy. Theoretical calculations suggest preserved tumour control. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  20. Hippocampal-Sparing Whole-Brain Radiotherapy: A 'How-To' Technique Using Helical Tomotherapy and Linear Accelerator-Based Intensity-Modulated Radiotherapy

    International Nuclear Information System (INIS)

    Gondi, Vinai; Tolakanahalli, Ranjini; Mehta, Minesh P.; Tewatia, Dinesh; Rowley, Howard; Kuo, John S.; Khuntia, Deepak; Tome, Wolfgang A.

    2010-01-01

    Purpose: Sparing the hippocampus during cranial irradiation poses important technical challenges with respect to contouring and treatment planning. Herein we report our preliminary experience with whole-brain radiotherapy using hippocampal sparing for patients with brain metastases. Methods and Materials: Five anonymous patients previously treated with whole-brain radiotherapy with hippocampal sparing were reviewed. The hippocampus was contoured, and hippocampal avoidance regions were created using a 5-mm volumetric expansion around the hippocampus. Helical tomotherapy and linear accelerator (LINAC)-based intensity-modulated radiotherapy (IMRT) treatment plans were generated for a prescription dose of 30 Gy in 10 fractions. Results: On average, the hippocampal avoidance volume was 3.3 cm 3 , occupying 2.1% of the whole-brain planned target volume. Helical tomotherapy spared the hippocampus, with a median dose of 5.5 Gy and maximum dose of 12.8 Gy. LINAC-based IMRT spared the hippocampus, with a median dose of 7.8 Gy and maximum dose of 15.3 Gy. On a per-fraction basis, mean dose to the hippocampus (normalized to 2-Gy fractions) was reduced by 87% to 0.49 Gy 2 using helical tomotherapy and by 81% to 0.73 Gy 2 using LINAC-based IMRT. Target coverage and homogeneity was acceptable with both IMRT modalities, with differences largely attributed to more rapid dose fall-off with helical tomotherapy. Conclusion: Modern IMRT techniques allow for sparing of the hippocampus with acceptable target coverage and homogeneity. Based on compelling preclinical evidence, a Phase II cooperative group trial has been developed to test the postulated neurocognitive benefit.

  1. BATH AND SHOWER EFFECTS IN THE RAT PAROTID GLAND EXPLAIN INCREASED RELATIVE RISK OF PAROTID GLAND DYSFUNCTION AFTER INTENSITY-MODULATED RADIOTHERAPY

    NARCIS (Netherlands)

    van Luijk, Peter; Faber, Hette; Schippers, Jacobus M.; Brandenburg, Sytze; Langendijk, Johannes A.; Meertens, Harm; Coppes, Robert P.

    2009-01-01

    Purpose: To assess in a rat model whether adding a subtolerance dose in a region adjacent to a high-dose irradiated subvolume of the parotid gland influences its response (bath-and-shower effect). Methods and Materials: Irradiation of the whole, cranial 50%, and/or the caudal 50% of the parotid

  2. Comparative analysis of volumetric-modulated arc therapy and intensity-modulated radiotherapy for base of tongue cancer

    International Nuclear Information System (INIS)

    Nithya, L.; Arulraj, Kumar; Rathinamuthu, Sasikumar; Pandey, Manish Bhushan; Nambi Raj, N. Arunai

    2014-01-01

    The aim of this study was to compare the various dosimetric parameters of dynamic multileaf collimator (MLC) intensity modulated radiation therapy (IMRT) plans with volumetric modulated arc therapy (VMAT) plans for base of tongue cases. All plans were done in Monaco planning system for Elekta synergy linear accelerator with 80 MLC. IMRT plans were planned with nine stationary beams, and VMAT plans were done for 360° arc with single arc or dual arc. The dose to the planning target volumes (PTV) for 70, 63, and 56 Gy was compared. The dose to 95, 98, and 50% volume of PTV were analyzed. The homogeneity index (HI) and the conformity index (CI) of the PTV 70 were also analyzed. IMRT and VMAT plan showed similar dose coverage, HI, and CI. Maximum dose and dose to 1-cc volume of spinal cord, planning risk volume (PRV) cord, and brain stem were compared. IMRT plan and VMAT plan showed similar results except for the 1 cc of PRV cord that received slightly higher dose in VMAT plan. Mean dose and dose to 50% volume of right and left parotid glands were analyzed. VMAT plan gave better sparing of parotid glands than IMRT. In normal tissue dose analyses VMAT was better than IMRT. The number of monitor units (MU) required for delivering the good quality of the plan and the time required to deliver the plan for IMRT and VMAT were compared. The number of MUs for VMAT was higher than that of IMRT plans. However, the delivery time was reduced by a factor of two for VMAT compared with IMRT. VMAT plans yielded good quality of the plan compared with IMRT, resulting in reduced treatment time and improved efficiency for base of tongue cases. (author)

  3. Comparative analysis of volumetric-modulated arc therapy and intensity-modulated radiotherapy for base of tongue cancer

    Directory of Open Access Journals (Sweden)

    L Nithya

    2014-01-01

    Full Text Available The aim of this study was to compare the various dosimetric parameters of dynamic multileaf collimator (MLC intensity modulated radiation therapy (IMRT plans with volumetric modulated arc therapy (VMAT plans for base of tongue cases. All plans were done in Monaco planning system for Elekta synergy linear accelerator with 80 MLC. IMRT plans were planned with nine stationary beams, and VMAT plans were done for 360° arc with single arc or dual arc. The dose to the planning target volumes (PTV for 70, 63, and 56 Gy was compared. The dose to 95, 98, and 50% volume of PTV were analyzed. The homogeneity index (HI and the conformity index (CI of the PTV 70 were also analyzed. IMRT and VMAT plan showed similar dose coverage, HI, and CI. Maximum dose and dose to 1-cc volume of spinal cord, planning risk volume (PRV cord, and brain stem were compared. IMRT plan and VMAT plan showed similar results except for the 1 cc of PRV cord that received slightly higher dose in VMAT plan. Mean dose and dose to 50% volume of right and left parotid glands were analyzed. VMAT plan gave better sparing of parotid glands than IMRT. In normal tissue dose analyses VMAT was better than IMRT. The number of monitor units (MU required for delivering the good quality of the plan and the time required to deliver the plan for IMRT and VMAT were compared. The number of MUs for VMAT was higher than that of IMRT plans. However, the delivery time was reduced by a factor of two for VMAT compared with IMRT. VMAT plans yielded good quality of the plan compared with IMRT, resulting in reduced treatment time and improved efficiency for base of tongue cases.

  4. A comparative study of standard intensity-modulated radiotherapy and RapidArc planning techniques for ipsilateral and bilateral head and neck irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Pursley, Jennifer, E-mail: jpursley@mgh.harvard.edu [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, MA (United States); Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA (United States); Damato, Antonio L.; Czerminska, Maria A.; Margalit, Danielle N. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, MA (United States); Sher, David J. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, MA (United States); Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX (United States); Tishler, Roy B. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, MA (United States)

    2017-04-01

    The purpose of this study was to investigate class solutions using RapidArc volumetric-modulated arc therapy (VMAT) planning for ipsilateral and bilateral head and neck (H&N) irradiation, and to compare dosimetric results with intensity-modulated radiotherapy (IMRT) plans. A total of 14 patients who received ipsilateral and 10 patients who received bilateral head and neck irradiation were retrospectively replanned with several volumetric-modulated arc therapy techniques. For ipsilateral neck irradiation, the volumetric-modulated arc therapy techniques included two 360° arcs, two 360° arcs with avoidance sectors around the contralateral parotid, two 260° or 270° arcs, and two 210° arcs. For bilateral neck irradiation, the volumetric-modulated arc therapy techniques included two 360° arcs, two 360° arcs with avoidance sectors around the shoulders, and 3 arcs. All patients had a sliding-window-delivery intensity-modulated radiotherapy plan that was used as the benchmark for dosimetric comparison. For ipsilateral neck irradiation, a volumetric-modulated arc therapy technique using two 360° arcs with avoidance sectors around the contralateral parotid was dosimetrically comparable to intensity-modulated radiotherapy, with improved conformity (conformity index = 1.22 vs 1.36, p < 0.04) and lower contralateral parotid mean dose (5.6 vs 6.8 Gy, p < 0.03). For bilateral neck irradiation, 3-arc volumetric-modulated arc therapy techniques were dosimetrically comparable to intensity-modulated radiotherapy while also avoiding irradiation through the shoulders. All volumetric-modulated arc therapy techniques required fewer monitor units than sliding-window intensity-modulated radiotherapy to deliver treatment, with an average reduction of 35% for ipsilateral plans and 67% for bilateral plans. Thus, for ipsilateral head and neck irradiation a volumetric-modulated arc therapy technique using two 360° arcs with avoidance sectors around the contralateral parotid is

  5. Urethra sparing – potential of combined Nickel–Titanium stent and intensity modulated radiation therapy in prostate cancer

    International Nuclear Information System (INIS)

    Thomsen, Jakob Borup; Arp, Dennis Tideman; Carl, Jesper

    2012-01-01

    Background and purpose: To investigate a novel method for sparing urethra in external beam radiotherapy of prostate cancer and to evaluate the efficacy of such a treatment in terms of tumour control using a mathematical model. Materials and methods: This theoretical study includes 20 patients previously treated for prostate cancer using external beam radiotherapy. All patients had a Nickel–Titanium (Ni–Ti) stent inserted into the prostate part of urethra. The stent has been used during the treatment course as an internal marker for patient positioning prior to treatment. In this study the stent is used for delineating urethra while intensity modulated radiotherapy was used for lowering dose to urethra. Evaluation of the dose plans were performed using a tumour control probability model based on the concept of uniform equivalent dose. Results: The feasibility of the urethra dose reduction method is validated and a reduction of about 17% is shown to be possible. Calculations suggest a nearly preserved tumour control probability. Conclusions: A new concept for urethra dose reduction is presented. The method relies on the use of a Ni–Ti stent as a fiducial marker combined with intensity modulated radiotherapy. Theoretical calculations suggest preserved tumour control.

  6. Anal wall sparing effect of an endorectal balloon in 3D conformal and intensity-modulated prostate radiotherapy.

    Science.gov (United States)

    Smeenk, Robert Jan; van Lin, Emile N J Th; van Kollenburg, Peter; Kunze-Busch, Martina; Kaanders, Johannes H A M

    2009-10-01

    To investigate the anal wall (Awall) sparing effect of an endorectal balloon (ERB) in 3D conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) for prostate cancer. In 24 patients with localized prostate carcinoma, two planning CT-scans were performed: with and without ERB. A prostate planning target volume (PTV) was defined, and the Awall was delineated, using two different methods. Three-field and 4-field 3D-CRT plans, and IMRT plans were generated with a prescription dose of 78Gy. In 144 treatment plans, the minimum dose (D(min)), maximum dose (D(max)), and mean dose (D(mean)) to the Awall were calculated, as well as the Awall volumes exposed to doses ranging from >or=20Gy to >or=70Gy (V(20)-V(70), respectively). In the 3D-CRT plans, an ERB significantly reduced D(mean), D(max), and V(30)-V(70). For IMRT all investigated dose parameters were significantly reduced by the ERB. The absolute reduction of D(mean) was 12Gy in 3D-CRT and was 7.5Gy in IMRT for both methods of Awall delineation. Application of an ERB showed a significant Awall sparing effect in both 3D-CRT and IMRT. This may lead to reduced late anal toxicity in prostate radiotherapy.

  7. Reducing Xerostomia After Chemo-IMRT for Head and Neck Cancer: Beyond Sparing the Parotid Glands

    Science.gov (United States)

    Little, Michael; Schipper, Matthew; Feng, Felix Y.; Vineberg, Karen; Cornwall, Craig; Murdoch-Kinch, Carol-Anne; Eisbruch, Avraham

    2011-01-01

    Purpose To assess whether in addition to sparing parotid glands (PGs), xerostomia after chemo-IMRT of head and neck cancer is affected by reducing doses to other salivary glands. Methods Prospective study: 78 patients with stages III/IV oropharynx/nasopharynx cancers received chemo-IMRT aiming to spare the parts outside the targets of bilateral PGs, oral cavity (OC) containing the minor salivary glands, and contralateral submandibular gland (SMG) (when contralateral level I was not a target). Pretherapy and periodically through 24 months, validated patient-reported xerostomia questionnaires (XQ) scores and observer-graded xerostomia were recorded, and stimulated and unstimulated saliva measured selectively from each of the PGs and SMGs. Mean OC doses served as surrogates of minor salivary glands dysfunction. Regression models assessed XQ and observer-graded xerostomia predictors. Results Statistically significant predictors of the XQ score in univariate analysis included OC, PG, and SMG mean doses, as well as baseline XQ score, time since RT, and both stimulated and unstimulated PG saliva flow rates. Similar factors were statistically significant predictors of observer-graded xerostomia. OC, PG and SMG mean doses were moderately inter-correlated (r=0.47–0.55). In multivariate analyses, after adjusting for PG and SMG doses, OC mean dose (p xerostomia. While scatter plots showed no thresholds, OC mean doses xerostomia at almost all post-therapy time points. Conclusion PG, SMG and OC mean doses were significant predictors of both patient-reported and observer-rated xerostomia after chemo-IMRT, with OC doses remaining significant after adjusting for PG and SMG doses. These results support efforts to spare all salivary glands by IMRT, beyond the PGs alone. PMID:22056067

  8. Texture analysis for the assessment of structural changes in parotid glands induced by radiotherapy

    International Nuclear Information System (INIS)

    Scalco, Elisa; Fiorino, Claudio; Cattaneo, Giovanni Mauro; Sanguineti, Giuseppe; Rizzo, Giovanna

    2013-01-01

    Background and purpose: During radiotherapy (RT) for head-and-neck cancer, parotid glands undergo significant anatomic, functional and structural changes which could characterize pre-clinical signs of an increased risk of xerostomia. Texture analysis is proposed to assess structural changes of parotids induced by RT, and to investigate whether early variations of textural parameters (such as mean intensity and fractal dimension) can predict parotid shrinkage at the end of treatment. Material and methods: Textural parameters and volumes of 42 parotids from 21 patients treated with intensity-modulated RT for nasopharyngeal cancer were extracted from CT images. To individuate which parameters changed during RT, a Wilcoxon signed-rank test between textural indices (first and second RT week; first and last RT week) was performed. Discriminant analysis was applied to variations of these parameters in the first two weeks of RT to assess their power in predicting parotid shrinkage at the end of RT. Results: A significant decrease in mean intensity (1.7 HU and 3.8 HU after the second and last weeks, respectively) and fractal dimension (0.016 and 0.021) was found. Discriminant analysis, based on volume and fractal dimension, was able to predict the final parotid shrinkage (accuracy of 71.4%). Conclusion: Textural features could be used in combination with volume to characterize structural modifications on parotid glands and to predict parotid shrinkage at the end of RT

  9. Anal wall sparing effect of an endorectal balloon in 3D conformal and intensity-modulated prostate radiotherapy

    International Nuclear Information System (INIS)

    Smeenk, Robert Jan; Lin, Emile N.J.Th. van; Kollenburg, Peter van; Kunze-Busch, Martina; Kaanders, Johannes H.A.M.

    2009-01-01

    Background and purpose: To investigate the anal wall (Awall) sparing effect of an endorectal balloon (ERB) in 3D conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) for prostate cancer. Materials and methods: In 24 patients with localized prostate carcinoma, two planning CT-scans were performed: with and without ERB. A prostate planning target volume (PTV) was defined, and the Awall was delineated, using two different methods. Three-field and 4-field 3D-CRT plans, and IMRT plans were generated with a prescription dose of 78 Gy. In 144 treatment plans, the minimum dose (D min ), maximum dose (D max ), and mean dose (D mean ) to the Awall were calculated, as well as the Awall volumes exposed to doses ranging from ≥20 Gy to ≥70 Gy (V 20 - V 70 , respectively). Results: In the 3D-CRT plans, an ERB significantly reduced D mean , D max , and V 30 - V 70 . For IMRT all investigated dose parameters were significantly reduced by the ERB. The absolute reduction of D mean was 12 Gy in 3D-CRT and was 7.5 Gy in IMRT for both methods of Awall delineation. Conclusions: Application of an ERB showed a significant Awall sparing effect in both 3D-CRT and IMRT. This may lead to reduced late anal toxicity in prostate radiotherapy.

  10. Impact of xerostomia on dysphagia after chemotherapy-intensity-modulated radiotherapy for oropharyngeal cancer: Prospective longitudinal study.

    Science.gov (United States)

    Vainshtein, Jeffrey M; Samuels, Stuart; Tao, Yebin; Lyden, Teresa; Haxer, Marc; Spector, Matthew; Schipper, Matthew; Eisbruch, Avraham

    2016-04-01

    The purpose of this study was to assess how xerostomia affects dysphagia. Prospective longitudinal studies of 93 patients with oropharyngeal cancer treated with definitive chemotherapy-intensity-modulated radiotherapy (IMRT). Observer-rated dysphagia (ORD), patient-reported dysphagia (PRD), and patient-reported xerostomia (PRX) assessment of the swallowing mechanics by videofluoroscopy (videofluoroscopy score), and salivary flow rates, were prospectively assessed from pretherapy through 2 years. ORD grades ≥2 were rare and therefore not modeled. Of patients with no/mild videofluoroscopy abnormalities, a substantial proportion had PRD that peaked 3 months posttherapy and subsequently improved. Through 2 years, highly significant correlations were observed between PRX and PRD scores for all patients, including those with no/mild videofluoroscopy abnormalities. Both PRX and videofluoroscopy scores were highly significantly associated with PRD. On multivariate analysis, PRX score was a stronger predictor of PRD than the videofluoroscopy score. Xerostomia contributes significantly to PRD. Efforts to further decrease xerostomia, in addition to sparing parotid glands, may translate into improvements in PRD. © 2015 Wiley Periodicals, Inc. Head Neck 38: E1605-E1612, 2016. © 2015 Wiley Periodicals, Inc.

  11. Magnetic resonance sialography for investigating major salivary gland duct system after intensity-modulated radiotherapy of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Ou Dan; He Xiayun; Zhang Yunyan

    2013-01-01

    We investigated the value of magnetic resonance sialography for evaluating xerostomia induced by intensity-modulated radiotherapy for nasopharyngeal carcinoma. Fourteen patients with nasopharyngeal carcinoma were treated with intensity-modulated radiotherapy. Salivary function was assessed by magnetic resonance sialography and subjective evaluation criteria pre-treatment, 1 week and 1 year post-radiotherapy. A magnetic resonance sialography categorical scoring system was used to compare the visibility of salivary ducts. The average mean dose was 38.93 Gy to the parotid glands and 59.34 Gy to the submandibular glands. Before radiotherapy, the visibility scores of both the parotid and submandibular ducts increased after secretion stimulation. The scores decreased and the response to stimulation was attenuated 1 week post-radiotherapy. For most of the parotid ducts, the visibility score improved at 1 year post-radiotherapy both at rest and under stimulation, but not for the submandibular ducts. With a median follow-up of 12.3 months, 8/12 patients had grade 1 xerostomia and 4/12 had grade 2 xerostomia. Magnetic resonance sialography allows non-invasive evaluation of radiation-induced ductal changes in the major salivary glands and enables reliable prediction of radiation-induced xerostomia. (author)

  12. Bone marrow-sparing intensity-modulated radiation therapy for Stage I seminoma

    International Nuclear Information System (INIS)

    Zilli, Thomas; Boudreau, Chantal; Doucet, Robert; Alizadeh, Moein; Lambert, Carole; Van Nguyen, Thu; Taussky, Daniel

    2011-01-01

    Background. A direct association between radiotherapy dose, side-effects and secondary cancers has been described in patients with seminoma. A treatment planning study was performed in order to compare computed tomography-based traditional radiotherapy (CT-tRT) versus bone marrow-sparing intensity-modulated radiation therapy (BMS-IMRT) in patients with Stage I seminoma. Material and methods. We optimized in 10 patients a CT-tRT and a BMS-IMRT treatment plan to deliver 20 Gy to the para-aortic nodes. CT-tRT and IMRT consisted of anteroposterior-posterioranterior parallel-opposed and seven non-opposed coplanar fields using 16 and 6-MV photon energies, respectively. Dose-Volume Histograms for clinical target volume (CTV), planning target volume (PTV) and organs at risk (OARs) were compared for both techniques using Wilcoxon matched-pair signed rank-test. Results. Dmean to CTV and PTV were similar for both techniques, even if CT-tRT showed a slightly improved target coverage in terms of PTV-D95% (19.7 vs. 19.5 Gy, p 0.005) and PTV-V95% (100 vs. 99.7%, p = 0.011) compared to BMS-IMRT. BMS-IMRT resulted in a significant reduction (5.2 Gy, p = 0.005) in the Dmean to the active bone marrow (ABM). The V100% and V75% of the OARs were reduced with BMS-IMRT by: ABM-V100% = 51.7% and ABM-V75% = 42.3%; bowel-V100% = 15.7% and bowel-V75% = 16.8%; stomach-V100% = 22% and stomach-V75% = 27.7%; pancreas-V100% = 37.1% and pancreas-V75% = 35.9% (p = 0.005 for all variables). Conclusions. BMS-IMRT reduces markedly the dose to the OARs compared to CT-tRT. This should translate into a reduction in acute and long-term toxicity, as well as into the risk of secondary solid and hematological cancers

  13. Kidney-Sparing Methods for Extended-Field Intensity-Modulated Radiotherapy (EF-IMRT) in Cervical Carcinoma Treatment.

    Science.gov (United States)

    Kunogi, Hiroaki; Yamaguchi, Nanae; Terao, Yasuhisa; Sasai, Keisuke

    2016-01-01

    Coplanar extended-field intensity-modulated radiation therapy (EF-IMRT) targeting the whole-pelvic and para-aortic lymph nodes in patients with advanced cervical cancer results in impaired creatinine clearance. An improvement in renal function cannot be expected unless low-dose (approximately 10 Gy) kidney exposure is reduced. The dosimetric method should be considered during EF-IMRT planning to further reduce low-dose exposure to the kidneys. To assess the usefulness of non-coplanar EF-IMRT with kidney-avoiding beams to spare the kidneys during cervical carcinoma treatment in dosimetric analysis between non-coplanar and coplanar EF-IMRT, we compared the doses of the target organ and organs at risk, including the kidney, in 10 consecutive patients. To estimate the influence of EFRT on renal dysfunction, creatinine clearance values after treatment were also examined in 18 consecutive patients. Of these 18 patients, 10 patients who were included in the dosimetric analysis underwent extended field radiation therapy (EFRT) with concurrent chemotherapy, and eight patients underwent whole-pelvis radiation therapy with concurrent chemotherapy to treat cervical carcinoma between April 2012 and March 2015 at our institution. In the dosimetric analysis, non-coplanar EF-IMRT was effective at reducing low-dose (approximately 10 Gy) exposure to the kidneys, thus maintaining target coverage and sparing other organs at risk, such as the small bowel, rectum, and bladder, compared with coplanar EF-IMRT. Renal function in all 10 patients who underwent EFRT, including coplanar EF-IMRT (with kidney irradiation), was low after treatment, and differed significantly from that of the eight patients who underwent WPRT (no kidney irradiation) 6 months after the first day of treatment (P = 0.005). In conclusion, non-coplanar EF-IMRT should be considered in patients with advanced cervical cancer, particularly in patients with a long life expectancy or with pre-existing renal dysfunction.

  14. Stereotactic body radiation therapy planning with duodenal sparing using volumetric-modulated arc therapy vs intensity-modulated radiation therapy in locally advanced pancreatic cancer: A dosimetric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Rachit; Wild, Aaron T.; Ziegler, Mark A.; Hooker, Ted K.; Dah, Samson D.; Tran, Phuoc T.; Kang, Jun; Smith, Koren; Zeng, Jing [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States); Pawlik, Timothy M. [Department of Surgery, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD (United States); Tryggestad, Erik [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States); Ford, Eric [Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Seattle, WA (United States); Herman, Joseph M., E-mail: jherma15@jhmi.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States)

    2013-10-01

    Stereotactic body radiation therapy (SBRT) achieves excellent local control for locally advanced pancreatic cancer (LAPC), but may increase late duodenal toxicity. Volumetric-modulated arc therapy (VMAT) delivers intensity-modulated radiation therapy (IMRT) with a rotating gantry rather than multiple fixed beams. This study dosimetrically evaluates the feasibility of implementing duodenal constraints for SBRT using VMAT vs IMRT. Non–duodenal sparing (NS) and duodenal-sparing (DS) VMAT and IMRT plans delivering 25 Gy in 1 fraction were generated for 15 patients with LAPC. DS plans were constrained to duodenal D{sub max} of<30 Gy at any point. VMAT used 1 360° coplanar arc with 4° spacing between control points, whereas IMRT used 9 coplanar beams with fixed gantry positions at 40° angles. Dosimetric parameters for target volumes and organs at risk were compared for DS planning vs NS planning and VMAT vs IMRT using paired-sample Wilcoxon signed rank tests. Both DS VMAT and DS IMRT achieved significantly reduced duodenal D{sub mean}, D{sub max}, D{sub 1cc}, D{sub 4%}, and V{sub 20} {sub Gy} compared with NS plans (all p≤0.002). DS constraints compromised target coverage for IMRT as demonstrated by reduced V{sub 95%} (p = 0.01) and D{sub mean} (p = 0.02), but not for VMAT. DS constraints resulted in increased dose to right kidney, spinal cord, stomach, and liver for VMAT. Direct comparison of DS VMAT and DS IMRT revealed that VMAT was superior in sparing the left kidney (p<0.001) and the spinal cord (p<0.001), whereas IMRT was superior in sparing the stomach (p = 0.05) and the liver (p = 0.003). DS VMAT required 21% fewer monitor units (p<0.001) and delivered treatment 2.4 minutes faster (p<0.001) than DS IMRT. Implementing DS constraints during SBRT planning for LAPC can significantly reduce duodenal point or volumetric dose parameters for both VMAT and IMRT. The primary consequence of implementing DS constraints for VMAT is increased dose to other organs at

  15. Impact of head and neck cancer adaptive radiotherapy to spare the parotid glands and decrease the risk of xerostomia

    International Nuclear Information System (INIS)

    Castelli, Joel; Simon, Antoine; Louvel, Guillaume; Henry, Olivier; Chajon, Enrique; Nassef, Mohamed; Haigron, Pascal; Cazoulat, Guillaume; Ospina, Juan David; Jegoux, Franck; Benezery, Karen; Crevoisier, Renaud de

    2015-01-01

    Large anatomical variations occur during the course of intensity-modulated radiation therapy (IMRT) for locally advanced head and neck cancer (LAHNC). The risks are therefore a parotid glands (PG) overdose and a xerostomia increase. The purposes of the study were to estimate: - the PG overdose and the xerostomia risk increase during a “standard” IMRT (IMRT std ); - the benefits of an adaptive IMRT (ART) with weekly replanning to spare the PGs and limit the risk of xerostomia. Fifteen patients received radical IMRT (70 Gy) for LAHNC. Weekly CTs were used to estimate the dose distributions delivered during the treatment, corresponding either to the initial planning (IMRT std ) or to weekly replanning (ART). PGs dose were recalculated at the fraction, from the weekly CTs. PG cumulated doses were then estimated using deformable image registration. The following PG doses were compared: pre-treatment planned dose, per-treatment IMRT std and ART. The corresponding estimated risks of xerostomia were also compared. Correlations between anatomical markers and dose differences were searched. Compared to the initial planning, a PG overdose was observed during IMRT std for 59% of the PGs, with an average increase of 3.7 Gy (10.0 Gy maximum) for the mean dose, and of 8.2% (23.9% maximum) for the risk of xerostomia. Compared to the initial planning, weekly replanning reduced the PG mean dose for all the patients (p < 0.05). In the overirradiated PG group, weekly replanning reduced the mean dose by 5.1 Gy (12.2 Gy maximum) and the absolute risk of xerostomia by 11% (p < 0.01) (30% maximum). The PG overdose and the dosimetric benefit of replanning increased with the tumor shrinkage and the neck thickness reduction (p < 0.001). During the course of LAHNC IMRT, around 60% of the PGs are overdosed of 4 Gy. Weekly replanning decreased the PG mean dose by 5 Gy, and therefore by 11% the xerostomia risk

  16. Impact of Salivary Gland Dosimetry on Post-IMRT Recovery of Saliva Output and Xerostomia Grade for Head-and-Neck Cancer Patients Treated With or Without Contralateral Submandibular Gland Sparing: A Longitudinal Study

    International Nuclear Information System (INIS)

    Wang Zhonghe; Yan Chao; Zhang Zhiyuan; Zhang Chenping; Hu Haisheng; Tu Wenyong; Kirwan, Jessica; Mendenhall, William M.

    2011-01-01

    Purpose: To observe the recovery of saliva output and effect on xerostomia grade after intensity-modulated radiotherapy (IMRT) with or without contralateral submandibular gland (cSMG) sparing and to assess the impact of salivary gland dosimetry on this recovery among patients with head-and-neck cancer. Methods and Materials: Between May 2007 and May 2008, 52 patients with head-and-neck cancer received definitive (n = 5 patients) and postoperative (n = 47 patients) IMRT at our institution, with at least one parotid gland spared. Of these patients, 26 patients with a low risk of recurrence in the cSMG region underwent IMRT and had their cSMGs spared (cSMG-sparing group). The remaining 26 high-risk patients had no cSMGs spared (cSMG-unspared group). Xerostomia grades and salivary flow rates were monitored at five time points (before IMRT and at 2, 6, 12, and 18 months after IMRT). Results: Average mean doses and mean volumes receiving 30 Gy (V30) of the cSMGs were lower in the cSMG-sparing group than in the cSMG-unspared group (mean dose, 20.4 Gy vs. 57.4 Gy; mean V30, 14.7% vs. 99.8%, respectively). Xerostomia grades at 2 and 6 months post-IMRT were also significantly lower among patients in the cSMG-sparing group than in the cSMG-unspared group, but differences were not significant at 12 and 18 months after IMRT. Patients in the cSMG-sparing group had significantly better mean unstimulated salivary flow rates at each time point post- IMRT as well as better mean stimulated salivary flow rates at 2 months post-IMRT. Conclusions: Recovery of saliva output and grade of xerostomia post-IMRT in patients whose cSMGs were spared were much better than in patients whose cSMGs were not spared. The influence of the mean doses to the cSMG and parotid gland on the recovery of saliva output was equivalent to that of the mean V30 to the glands.

  17. Impact of Salivary Gland Dosimetry on Post-IMRT Recovery of Saliva Output and Xerostomia Grade for Head-and-Neck Cancer Patients Treated With or Without Contralateral Submandibular Gland Sparing: A Longitudinal Study

    Energy Technology Data Exchange (ETDEWEB)

    Wang Zhonghe; Yan Chao [Division of Radiation Oncology, the Shanghai Ninth Peoples Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai (China); Zhang Zhiyuan; Zhang Chenping [Department of Oral and Maxillofacial Surgery, the Shanghai Ninth Peoples Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai (China); Hu Haisheng; Tu Wenyong [Division of Radiation Oncology, the Shanghai Ninth Peoples Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai (China); Kirwan, Jessica [Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida (United States); Mendenhall, William M., E-mail: mendwm@shands.ufl.edu [Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida (United States)

    2011-12-01

    Purpose: To observe the recovery of saliva output and effect on xerostomia grade after intensity-modulated radiotherapy (IMRT) with or without contralateral submandibular gland (cSMG) sparing and to assess the impact of salivary gland dosimetry on this recovery among patients with head-and-neck cancer. Methods and Materials: Between May 2007 and May 2008, 52 patients with head-and-neck cancer received definitive (n = 5 patients) and postoperative (n = 47 patients) IMRT at our institution, with at least one parotid gland spared. Of these patients, 26 patients with a low risk of recurrence in the cSMG region underwent IMRT and had their cSMGs spared (cSMG-sparing group). The remaining 26 high-risk patients had no cSMGs spared (cSMG-unspared group). Xerostomia grades and salivary flow rates were monitored at five time points (before IMRT and at 2, 6, 12, and 18 months after IMRT). Results: Average mean doses and mean volumes receiving 30 Gy (V30) of the cSMGs were lower in the cSMG-sparing group than in the cSMG-unspared group (mean dose, 20.4 Gy vs. 57.4 Gy; mean V30, 14.7% vs. 99.8%, respectively). Xerostomia grades at 2 and 6 months post-IMRT were also significantly lower among patients in the cSMG-sparing group than in the cSMG-unspared group, but differences were not significant at 12 and 18 months after IMRT. Patients in the cSMG-sparing group had significantly better mean unstimulated salivary flow rates at each time point post- IMRT as well as better mean stimulated salivary flow rates at 2 months post-IMRT. Conclusions: Recovery of saliva output and grade of xerostomia post-IMRT in patients whose cSMGs were spared were much better than in patients whose cSMGs were not spared. The influence of the mean doses to the cSMG and parotid gland on the recovery of saliva output was equivalent to that of the mean V30 to the glands.

  18. Large Parotid Gland Lipoblastoma in a Teenager.

    Science.gov (United States)

    Jandali, Danny; Heilingoetter, Ashley; Ghai, Ritu; Jeffe, Jill; Al-Khudari, Samer

    2018-01-01

    Lipoblastomas are rare benign neoplasms that arise from fetal white fat cells. They are typically found in children under the age of 3 and have been reported in the mediastinum, extremities, and infrequently in the head and neck. We present a rare case of a lipoblastoma arising from the parotid gland and the first known report of a parotid lipoblastoma in a teenager. A 15-year-old male presented with a painless, slowly enlarging parotid mass and left facial swelling. A fine needle aspiration was non-diagnostic and initial MRI showed a 3.8 cm × 5.0 cm × 4.0 cm fatty lesion involving the superficial and deep lobes of the left parotid gland and masticator space with widening of the stylo-mandibular tunnel and thinning of the adjacent mandibular condyle. The patient was taken to the operating room, and the mass was excised under general anesthesia via a transcervical parotid approach with facial nerve monitoring. The most superficial aspect of the parotid bed was spared and with upper and lower divisions of the facial nerve preserved. The tumor, which primarily involved the deep lobe of the parotid, was entirely excised. Final pathology revealed a 5.2 cm lipoblastoma. The patient did well post-operatively with full function of the facial nerve and 20 months of follow up without evidence of recurrence. This is the first reported case of a lipoblastoma of the parotid gland in a teenager. Although a rare tumor, it should be considered in the differential diagnosis of a parotid mass in this population.

  19. Large Parotid Gland Lipoblastoma in a Teenager

    Directory of Open Access Journals (Sweden)

    Danny Jandali

    2018-03-01

    Full Text Available BackgroundLipoblastomas are rare benign neoplasms that arise from fetal white fat cells. They are typically found in children under the age of 3 and have been reported in the mediastinum, extremities, and infrequently in the head and neck. We present a rare case of a lipoblastoma arising from the parotid gland and the first known report of a parotid lipoblastoma in a teenager.Case presentationA 15-year-old male presented with a painless, slowly enlarging parotid mass and left facial swelling. A fine needle aspiration was non-diagnostic and initial MRI showed a 3.8 cm × 5.0 cm × 4.0 cm fatty lesion involving the superficial and deep lobes of the left parotid gland and masticator space with widening of the stylo-mandibular tunnel and thinning of the adjacent mandibular condyle. The patient was taken to the operating room, and the mass was excised under general anesthesia via a transcervical parotid approach with facial nerve monitoring. The most superficial aspect of the parotid bed was spared and with upper and lower divisions of the facial nerve preserved. The tumor, which primarily involved the deep lobe of the parotid, was entirely excised. Final pathology revealed a 5.2 cm lipoblastoma. The patient did well post-operatively with full function of the facial nerve and 20 months of follow up without evidence of recurrence.ConclusionThis is the first reported case of a lipoblastoma of the parotid gland in a teenager. Although a rare tumor, it should be considered in the differential diagnosis of a parotid mass in this population.

  20. Intensity-modulated arc therapy simplified

    International Nuclear Information System (INIS)

    Wong, Eugene; Chen, Jeff Z.; Greenland, Jonathan

    2002-01-01

    Purpose: We present a treatment planning strategy for intensity-modulated radiation therapy using gantry arcs with dynamic multileaf collimator, previously termed intensity-modulated arc therapy (IMAT). Methods and Materials: The planning strategy is an extension of the photon bar arc and asymmetric arc techniques and is classified into three levels of complexity, with increasing number of gantry arcs. This principle allows us to generalize the analysis of the number of arcs required for intensity modulation for a given treatment site. Using a phantom, we illustrate how the current technique is more flexible than the photon bar arc technique. We then compare plans from our strategy with conventional three-dimensional conformal treatment plans for three sites: prostate (prostate plus seminal vesicles), posterior pharyngeal wall, and chest wall. Results: Our strategy generates superior IMAT treatment plans compared to conventional three-dimensional conformal plans. The IMAT plans spare critical organs well, and the trade-off for simplicity is that the dose uniformity in the target volume may not rival that of true inverse treatment plans. Conclusions: The analyses presented in this paper give a better understanding of IMAT plans. Our strategy is easier to understand and more efficient in generating plans than inverse planning systems; our plans are also simpler to modify, and quality assurance is more intuitive

  1. Nasopharyngeal Carcinoma Treated with Precision-Oriented Radiation Therapy Techniques Including Intensity-Modulated Radiotherapy: Preliminary Results

    Directory of Open Access Journals (Sweden)

    Wen-Shan Liu

    2004-02-01

    Full Text Available This paper reports preliminary results with intensity-modulated radiotherapy (IMRT in nasopharyngeal carcinoma (NPC. Between August 2000 and May 2001, we treated 19 patients with NPC using IMRT. Twelve patients had stage I-II disease and seven had stage III-IV disease. Six patients received 9.0-19.8 Gy three-dimensional conformal radiotherapy (3D-CRT before IMRT and 18 patients received a brachytherapy boost after IMRT. The mean follow-up time was 13.0 months. All patients with stage II-IV disease except one received two cycles of chemoradiotherapy with cisplatin and 5-fluorouracil (5-FU during radiotherapy, followed by two to four cycles of chemotherapy after radiotherapy. Tumor response was assessed using clinical examination and computerized tomography or magnetic resonance imaging. The mean doses administered to the gross tumor volume and clinical tumor volume were 70.9 Gy and 63.2 Gy, respectively. The mean doses administered to the right and left parotid glands were 38.1 Gy and 38.6 Gy, respectively. All 19 patients had a complete response of primary and lymph node disease. Grade III mucositis developed during chemoradiotherapy in 15 patients (79%. In addition, clinical grade I xerostomia was recorded in nine patients, grade II in nine, and grade III in one. This study demonstrated that 3D-CRT, IMRT, intracavitary brachytherapy, and chemotherapy are effective and safe methods to treat NPC. Although IMRT treatment spared parotid gland function, its efficacy may be significantly influenced by disease stage and location of the neck lymph nodes. More cases and a longer follow-up to assess survival and complications are planned.

  2. Larynx-sparing techniques using intensity-modulated radiation therapy for oropharyngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bar Ad, Voichita, E-mail: voichita.bar-ad@jeffersonhospital.org [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States); Lin, Haibo [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States); Hwang, Wei-Ting [Department of Biostatistics and Epidemiology, University of Pennsylvania, Philadelphia, PA (United States); Deville, Curtiland [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States); Dutta, Pinaki R. [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States); Department of Biostatistics and Epidemiology, University of Pennsylvania, Philadelphia, PA (United States); Tochner, Zelig; Both, Stefan [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA (United States)

    2012-01-01

    The purpose of the current study was to explore whether the laryngeal dose can be reduced by using 2 intensity-modulated radiation therapy (IMRT) techniques: whole-neck field IMRT technique (WF-IMRT) vs. junctioned IMRT (J-IMRT). The effect on planning target volumes (PTVs) coverage and laryngeal sparing was evaluated. WF-IMRT technique consisted of a single IMRT plan, including the primary tumor and the superior and inferior neck to the level of the clavicular heads. The larynx was defined as an organ at risk extending superiorly to cover the arytenoid cartilages and inferiorly to include the cricoid cartilage. The J-IMRT technique consisted of an IMRT plan for the primary tumor and the superior neck, matched to conventional antero-posterior opposing lower neck fields at the level of the thyroid notch. A central block was used for the anterior lower neck field at the level of the larynx to restrict the dose to the larynx. Ten oropharyngeal cancer cases were analyzed. Both the primary site and bilateral regional lymphatics were included in the radiotherapy targets. The averaged V95 for the PTV57.6 was 99.2% for the WF-IMRT technique compared with 97.4% (p = 0.02) for J-IMRT. The averaged V95 for the PTV64 was 99.9% for the WF-IMRT technique compared with 98.9% (p = 0.02) for J-IMRT and the averaged V95 for the PT70 was 100.0% for WF-IMRT technique compared with 99.5% (p = 0.04) for J-IMRT. The averaged mean laryngeal dose was 18 Gy with both techniques. The averaged mean doses within the matchline volumes were 69.3 Gy for WF-MRT and 66.2 Gy for J-IMRT (p = 0.03). The WF-IMRT technique appears to offer an optimal coverage of the target volumes and a mean dose to the larynx similar with J-IMRT and should be further evaluated in clinical trials.

  3. 3 T MR 3D fast imaging employing steady state acquisition demonstrating branches of intraparotid facial nerve, parotid duct, and relation with parotid tumors

    International Nuclear Information System (INIS)

    Li Yan; Li Chuanting; Zhang Dongsheng; Ai Bin; Zhang Weidong; Wu Lebin

    2010-01-01

    Objective: To investigate the usefulness of 3 T MRI 3D-FIESTA in the evaluation of the intraparotid components of the facial nerve and parotid duct, and compare them with surgical findings. Methods: Twenty-two cases with parotid benign tumors were scanned with conventional and 3D-FIESTA sequences on 3 T MRI scanner. Postprocessed multiplanar images were obtained with the workstation. Parotid ducts and facial nerves and tumors were identified on these images. The relationship of the tumors to the facial nerves and Parotid ducts was confirmed at surgery. Results: Various types of parotid benign tumors had their characteristics on 3 T MR imaging. Parotid benign tumors mainly showed hypo-intensity on T 1 WI in 21 cases, and hyper-intensity on T 2 WI in 22 cases. But on 3D-FIESTA images, they appeared hypointensity (10 cases) or high intensity (12 cases) due to different types. Facial nerves in parotid appeared as linear structures with hypo-inteusity. The indication of the main trunks were 16 and 18 cases for T 1 WI and T 2 WI images, while on 3D-FIESTA images, the main trunks and cervicofacial and temporofacial divisions of the facial nerves were found in 22, 21,22 cases. Parotid ducts appeared as structures with hypo-intensity on T 1 WI and hyper-intensity on multiplanar images (14, 20, 22 cases). Compared with surgical results, the main trunks of the facial nerve were correctly showed by 3D-FIESTA images in 20 cases. However, in 2 cases they were not located in the operation because of shifting. Conclusion: 3 T MR 3D-FIESTA imaging could depict the extracranial facial nerve and the parotid duct in the parotid gland, which is useful for preoperative evaluation of parotid gland tumors. (authors)

  4. Sequentially delivered boost plans are superior to simultaneously delivered plans in head and neck cancer when the boost volume is located further away from the parotid glands

    International Nuclear Information System (INIS)

    Lamers-Kuijper, Emmy; Heemsbergen, Wilma; Mourik, Anke van; Rasch, Coen

    2011-01-01

    Purpose: To find parameters that predict which head and neck patients benefit from a sequentially delivered boost treatment plan compared to a simultaneously delivered plan, with the aim to spare the salivary glands. Methods and materials: We evaluated 50 recently treated head and neck cancer patients. Apart from the clinical plan with a sequentially (SEQ) given boost using an Intensity Modulated Radiotherapy Technique (IMRT), a simultaneous integrated boost (SIB) technique plan was constructed with the same beam set-up. The mean dose to the parotid glands was calculated and compared. The elective nodal areas were bilateral in all cases, with a boost on either one side or both sides of the neck. Results: When the parotid gland volume and the Planning Target Volume (PTV) for the boost overlap there is on average a lower dose to the parotid gland with a SIB technique (-1.2 Gy), which is, however, not significant (p = 0.08). For all parotid glands with no boost PTV overlap, there is a benefit from a SEQ technique compared to a SIB technique for the gland evaluated (on average a 2.5 Gy lower dose to the parotid gland, p < 0.001). When the distance between gland and PTV is 0-1 cm, this difference is on average 0.8 Gy, for 1-2 cm distance 2.9 Gy and for glands with a distance greater than 2 cm, 3.3 Gy. When the lymph nodes on the evaluated side are also included in the boost PTV, however, this relationship between the distance and the gain of a SEQ seems less clear. Conclusions: A sequentially delivered boost technique results in a better treatment plan for most cases, compared to a simultaneous integrated boost IMRT technique, if the boost PTV is more than 1 cm away from at least one parotid gland.

  5. Evaluation of xerostomia following intensity modulated radiotherapy (IMRT) for head and neck cancer patients

    International Nuclear Information System (INIS)

    Lee, Seok Ho; Kim, Tae Hyun; Chie, Eui Kyu

    2004-01-01

    This study was done to evaluate xerostomia following intensity modulated radiotherapy for patients with head and neck cancer, and to analyze the correlation between the dosimetric parameters and xerostomia parameters. From February till October 2003, 13 patients with 3 months of follow-up were evaluated for xerostomia after being treated for head and neck cancer with IMRT. Their median age was 57 years (range:43 ∼ 77). Xerostomia were assessed with a 4-question xerostomia questionnaire score (XQS) and a test for salivary flow rates (unstimulated and stimulated). The patients were also given a validated LENT SOMA scale (LSC) questionnaire. The evaluations were completed before radiation therapy (pre-RT) and at 1 and. 3 months after radiation therapy (RT). We evaluated xerostomia at pre-RT, 1 and, 3 months after RT. The association between the xerostomia parameters (XQS and LSC) and salivary flow rates (unstimulated and stimulated: USFR and SSFR) was assessed at 1 and 3 months after RT. All 13 patients showed no significant changes in XQS, LSC and Salivary Flow rates. As a result, we couldn't find out about xerostomia development. Based on the total mean parotid dose, 3,500 cGy, we divided these patients into two groups. The 8 patients (< 3,500 cGy) showed no significant changes in XQS, LSC and Salivary Flow rates. However, in 5 patients (≥ 3,500 cGy), there was a significant increase in USFR and, SSFR at 3 months after RT, and for the XQS and, LSC at 1 and 3 months after RT. The correlation between XQS and, LSC, and USFR and, SSFR in all patients (13) was significant at 3 months after RT. The correlation had a tendency to the decrease for USFR and, SSFR in proportion to the increase of XQS and, LSC. Base on the results of this study, IMRT seem to be an effective treatment to significantly decrease the xerostomia. XQS and, LSC seem to be a effective tool for predicting the xerostomia. A total parotid gland mean dose of < 3,500 cGy should be a planning goal if

  6. Xerostomia after radiotherapy. What matters - mean total dose or dose to each parotid gland?

    International Nuclear Information System (INIS)

    Tribius, S.; Sommer, J.; Prosch, C.; Bajrovic, A.; Kruell, A.; Petersen, C.; Muenscher, A.; Blessmann, M.; Todorovic, M.; Tennstedt, P.

    2013-01-01

    Purpose: Xerostomia is a debilitating side effect of radiotherapy in patients with head and neck cancer. We undertook a prospective study of the effect on xerostomia and outcomes of sparing one or both parotid glands during radiotherapy for patients with squamous cell carcinoma of the head and neck. Methods and materials: Patients with locally advanced squamous cell carcinoma of the head and neck received definitive (70 Gy in 2 Gy fractions) or adjuvant (60-66 Gy in 2 Gy fractions) curative-intent radiotherapy using helical tomotherapy with concurrent chemotherapy if appropriate. Group A received < 26 Gy to the left and right parotids and group B received < 26 Gy to either parotid. Results: The study included 126 patients; 114 (55 in group A and 59 in group B) had follow-up data. There were no statistically significant differences between groups in disease stage. Xerostomia was significantly reduced in group A vs. group B (p = 0.0381). Patients in group A also had significantly less dysphagia. Relapse-free and overall survival were not compromised in group A: 2-year relapse-free survival was 86% vs. 72% in group B (p = 0.361); 2-year overall survival was 88% and 76%, respectively (p = 0.251). Conclusion: This analysis suggests that reducing radiotherapy doses to both parotid glands to < 26 Gy can reduce xerostomia and dysphagia significantly without compromising survival. Sparing both parotids while maintaining target volume coverage and clinical outcome should be the treatment goal and reporting radiotherapy doses delivered to the individual parotids should be standard practice. (orig.)

  7. Xerostomia after radiotherapy. What matters - mean total dose or dose to each parotid gland?

    Energy Technology Data Exchange (ETDEWEB)

    Tribius, S.; Sommer, J.; Prosch, C.; Bajrovic, A.; Kruell, A.; Petersen, C. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Radiation Oncology; Muenscher, A. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Otorhinolaryngology and Head and Neck Surgery; Blessmann, M. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Oral and Maxillofacial Surgery; Todorovic, M. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Medical Physics; Tennstedt, P. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Martini-Clinic, Prostate Cancer Center

    2013-03-15

    Purpose: Xerostomia is a debilitating side effect of radiotherapy in patients with head and neck cancer. We undertook a prospective study of the effect on xerostomia and outcomes of sparing one or both parotid glands during radiotherapy for patients with squamous cell carcinoma of the head and neck. Methods and materials: Patients with locally advanced squamous cell carcinoma of the head and neck received definitive (70 Gy in 2 Gy fractions) or adjuvant (60-66 Gy in 2 Gy fractions) curative-intent radiotherapy using helical tomotherapy with concurrent chemotherapy if appropriate. Group A received < 26 Gy to the left and right parotids and group B received < 26 Gy to either parotid. Results: The study included 126 patients; 114 (55 in group A and 59 in group B) had follow-up data. There were no statistically significant differences between groups in disease stage. Xerostomia was significantly reduced in group A vs. group B (p = 0.0381). Patients in group A also had significantly less dysphagia. Relapse-free and overall survival were not compromised in group A: 2-year relapse-free survival was 86% vs. 72% in group B (p = 0.361); 2-year overall survival was 88% and 76%, respectively (p = 0.251). Conclusion: This analysis suggests that reducing radiotherapy doses to both parotid glands to < 26 Gy can reduce xerostomia and dysphagia significantly without compromising survival. Sparing both parotids while maintaining target volume coverage and clinical outcome should be the treatment goal and reporting radiotherapy doses delivered to the individual parotids should be standard practice. (orig.)

  8. Conformal radiotherapy with intensity modulation and integrated boost in the head and neck cancers: experience of the Curie Institute

    International Nuclear Information System (INIS)

    Toledano, I.; Serre, A.; Bensadoun, R.J.; Ortholan, C.; Racadot, S.; Calais, G.; Alfonsi, M.; Giraud, P.; Graff, P.; Serre, A.; Bensadoun, R.J.; Ortholan, C.; Racadot, S.; Calais, G.; Alfonsi, M.; Giraud, P.

    2009-01-01

    The modulated intensity radiotherapy (I.M.R.T.) is used in the treatment of cancers in superior aero digestive tracts to reduce the irradiation of parotids and to reduce the delayed xerostomia. This retrospective study presents the results got on the fourteen first patients according an original technique of I.M.R.T. with integrated boost. It appears that this technique is feasible and allows to reduce the xerostomia rate without modifying the local control rate. To limit the average dose to the parotids under 30 Gy seems reduce the incidence of severe xerostomia. (N.C.)

  9. [Acute parotiditis after tracheostomy in Intensive Care].

    Science.gov (United States)

    Serviá Goixart, L; Badía, M; Campi, D; Trujillano, J; Alcega, R; Vilanova, J

    2006-01-01

    Post-anesthesic parotiditis is a little known entity related with anesthesic procedures but described in any situation that motivates manipulation of the oropharyngeal cavity. Its physiopathological mechanism is not well-defined, although it could have a multifactorial origin. A case of a male who was admitted for post-operative control of brain tumor exeresis and who had preauricular and submaxillary inflammation after a routinely performed tracheostomy is presented. Coincidence with the performing of a tracheostomy required us to propose the differential diagnosis with the complications associated to said surgical act. Post-anesthesic parotiditis, even though it is a rare complication and has no clinical significance, should be kept in mind when there is facial edema after any manipulation of the oropharyngeal cavity.

  10. Intensity modulated radiation therapy using laser-accelerated protons: a Monte Carlo dosimetric study

    International Nuclear Information System (INIS)

    Fourkal, E; Li, J S; Xiong, W; Nahum, A; Ma, C-M

    2003-01-01

    In this paper we present Monte Carlo studies of intensity modulated radiation therapy using laser-accelerated proton beams. Laser-accelerated protons coming out of a solid high-density target have broad energy and angular spectra leading to dose distributions that cannot be directly used for therapeutic applications. Through the introduction of a spectrometer-like particle selection system that delivers small pencil beams of protons with desired energy spectra it is feasible to use laser-accelerated protons for intensity modulated radiotherapy. The method presented in this paper is a three-dimensional modulation in which the proton energy spectrum and intensity of each individual beamlet are modulated to yield a homogeneous dose in both the longitudinal and lateral directions. As an evaluation of the efficacy of this method, it has been applied to two prostate cases using a variety of beam arrangements. We have performed a comparison study between intensity modulated photon plans and those for laser-accelerated protons. For identical beam arrangements and the same optimization parameters, proton plans exhibit superior coverage of the target and sparing of neighbouring critical structures. Dose-volume histogram analysis of the resulting dose distributions shows up to 50% reduction of dose to the critical structures. As the number of fields is decreased, the proton modality exhibits a better preservation of the optimization requirements on the target and critical structures. It is shown that for a two-beam arrangement (parallel-opposed) it is possible to achieve both superior target coverage with 5% dose inhomogeneity within the target and excellent sparing of surrounding tissue

  11. The normal tissue sparing obtained with simultaneous treatment of pelvic lymph nodes and bladder using intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Soendergaard, Jimmi; Hoeyer, Morten; Wright, Pauliina; Grau, Cai; Muren, Ludvig Paul; Petersen, Joergen B.

    2009-01-01

    We have implemented an intensity-modulated radiotherapy (IMRT) protocol for simultaneous irradiation of bladder and lymph nodes. In this report, doses to normal tissue from IMRT and our previous conformal sequential boost technique are compared. Material and methods. Sixteen patients with urinary bladder cancer were treated using a six-field dynamic IMRT beam arrangement delivering 60 Gy to the bladder and 48 Gy to the pelvic lymph nodes. Dose-volume histogram (DVH) parameters for relevant normal tissues (bowel, bowel cavity, rectum and femoral heads) for the IMRT plans were compared with corresponding DVHs from our previous conformal sequential boost technique. Calculations of the generalized Equivalent Uniform Dose (gEUD) were performed for the bowel, with a reference volume of 200 cm 3 and a volume effect parameter k = 4, as well as for the rectum, using k = 12. Acute gastrointestinal (GI) and genitourinary (GU) RTOG toxicity was recorded. Results. Statistical significant normal tissue sparing was obtained by IMRT. For the bowel, a significant reduction was obtained at all dose levels between 20 and 50 Gy (p 3 at 50 Gy, while the gEUD was reduced from 58 to 53 Gy (p 3 at 50 Gy. The rectum gEUD was reduced from 55 to 53 Gy (p < 0.05). For the femoral heads, IMRT reduced the maximum dose as well as the volumes above all dose levels. The rate of acute peak Grade 2 GI RTOG complications was 38% after IMRT. Conclusion. IMRT to the urinary bladder and elective lymph nodes result in considerable normal tissue sparing compared to conformal sequential boost technique. This has paved the way for further studies combining IMRT with image-guided radiotherapy (IGRT) in bladder cancer

  12. Cervix carcinomas: place of intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Barillot, I.

    2009-01-01

    While indications of modulated intensity radiation therapy (I.M.R.T.) are perfectly defined in head and neck and prostate cancer patients, this technique remains under evaluation for gynecologic tumours. The implementation of conformal three dimensional radiotherapy in the late 1990 has been the first important step for optimisation of treatment of cervix carcinomas, as it permitted a better target coverage with a significant reduction of the bladder dose. However, this technique often leads to an irradiation of a larger volume of rectum in locally advanced stages and could only spare a limited amount of intestine. I.R.M.T. is one of the optimisation methods potentially efficient for a better sparing of digestive tract during irradiation of cervix carcinomas. The aim of this literature review is to provide the arguments supporting this hypothesis, and to define the place of this technique for dose escalation. (authors)

  13. High-risk factors of parotid lymph node metastasis in nasopharyngeal carcinoma: a case-control study

    International Nuclear Information System (INIS)

    Wang, Hong-zhi; Cao, Cai-neng; Luo, Jing-wei; Yi, Jun-lin; Huang, Xiao-dong; Zhang, Shi-ping; Wang, Kai; Qu, Yuan; Xiao, Jian-ping; Li, Su-yan; Gao, Li; Xu, Guo-zhen

    2016-01-01

    Although parotid-sparing IMRT decreased the dose distribution of parotid, parotid region recurrence has been reported. Prophylactic irradiation in parotid area would be necessary in patients with high risk of parotid lymph node metastasis (PLNM). This study was to detect the high-risk factors of PLNM in nasopharyngeal carcinoma. This was a 1:2 case-control study. All patients in this study were newly diagnosed NPC with N2-3 classification from January 2005 to December 2012. Cases were 22 sides with ipsilateral PLNM. Controls were 44 patients who were randomly selected from N2-3 disease in database. 20/1096 (1.82 %) NPC patients were found PLNM. Sum of the longest diameter for multiple lymph nodes (SLD) in level II was larger in case group than that in control group (6.0 cm vs. 3.6 cm, p = 0.003). Level II lymph node necrosis, level Va/b involvement, and rare neck areas involvement were more common in case group (p = 0.016, p = 0.034, and p < 0.001, respectively). RPN, level III, and level IV metastases showed no significant difference between the two groups. Multivariate analysis in logistic regression showed that only SLD ≥5 cm in II area (OR = 4.11, p = 0.030) and rare neck areas involvement (OR = 3.95, p = 0.045) were associated with PLNM in NPC patients. PLNM was an uncommon event in NPC patients. SLD ≥5 cm in level II and involvement in rare-neck areas may be potentially high-risk factors for PLNM. Sparing parotid in IMRT was not recommended for NPC patients with high risks of PLNM

  14. A longitudinal evaluation of early anatomical changes of parotid gland in intensity modulated radiotherapy of nasopharyngeal carcinoma patients with parapharyngeal space involvement.

    Science.gov (United States)

    Zhang, Yingting; Lin, Chengguang; Wu, Jianhua; Jiang, Xiaobo; Lee, Shara W Y; Tam, Shing-Yau; Wu, Vincent W C

    2017-09-01

    Radiotherapy of nasopharyngeal carcinoma patients with parapharyngeal space (PPS) involvement may deliver high dose to the parotid gland. This study evaluated parotid gland changes during and up to 3 months after radiotherapy. Kilovoltage computed tomography (CT) scans of head and neck region of 39 nasopharyngeal carcinoma patients with PPS involvement were performed at pre-radiotherapy, 10th, 20th and 30th fractions and 3 months after treatment. The parotid glands were contoured in pre-radiotherapy planning CT scan and in subsequent scans. Dice similarity coefficient (DSC), percentage volume change and centroid movement between the planning CT and the subsequent CTs were obtained from the contouring software. In addition, the distance between medial and lateral borders of parotid glands from the mid-line at various time intervals were also measured. The ipsilateral parotid gland received a mean dose of about 5 Gy higher than the contralateral side. The mean DSC and parotid volume decreased by more than 30% at 20th fraction and reached the minimum at 30th fraction. Partial recovery was observed at 3 months after treatment. The centroid displacement followed a similar pattern, which moved medially and superiorly by an average of 0.30 cm and 0.18 cm, respectively, at 30th fraction. The changes in ipsilateral gland were slightly greater than the contralateral side. Substantial volume change and medial movement of parotid gland were observed with slightly greater magnitude in the ipsilateral side. Adaptive radiotherapy was suggested at around 15th to 20th fraction so as to optimise the original dose distribution of the plan. © 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

  15. Swallowing sparing intensity modulated radiotherapy (SW-IMRT) in head and neck cancer : Clinical validation according to the model-based approach

    NARCIS (Netherlands)

    Christianen, Miranda E. M. C.; van der Schaaf, Arjen; van der Laan, Hans Paul; Verdonck-de Leeuw, Irma M.; Doornaert, Patricia; Chouvalova, Olga; Steenbakkers, Roel J. H. M.; Leemans, Charles Rene; Oosting, Sjoukje F.; van der Laan, Bernard F. A. M.; Roodenburg, Jan L. N.; Slotman, Ben J.; Bijl, Hendrik P.; Langendijk, Johannes A.

    Purpose: The aim of this study was to clinically validate a multivariable normal tissue complication probability (NTCP) model for grade 2-4 swallowing dysfunction at 6 months after radiotherapy or chemoradiation (SWAL(M6)) in head and neck cancer patients treated with swallowing sparing intensity

  16. Critical structure sparing in stereotactic ablative radiotherapy for central lung lesions: helical tomotherapy vs. volumetric modulated arc therapy.

    Directory of Open Access Journals (Sweden)

    Alexander Chi

    Full Text Available BACKGROUND: Helical tomotherapy (HT and volumetric modulated arc therapy (VMAT are both advanced techniques of delivering intensity-modulated radiotherapy (IMRT. Here, we conduct a study to compare HT and partial-arc VMAT in their ability to spare organs at risk (OARs when stereotactic ablative radiotherapy (SABR is delivered to treat centrally located early stage non-small-cell lung cancer or lung metastases. METHODS: 12 patients with centrally located lung lesions were randomly chosen. HT, 2 & 8 arc (Smart Arc, Pinnacle v9.0 plans were generated to deliver 70 Gy in 10 fractions to the planning target volume (PTV. Target and OAR dose parameters were compared. Each technique's ability to meet dose constraints was further investigated. RESULTS: HT and VMAT plans generated essentially equivalent PTV coverage and dose conformality indices, while a trend for improved dose homogeneity by increasing from 2 to 8 arcs was observed with VMAT. Increasing the number of arcs with VMAT also led to some improvement in OAR sparing. After normalizing to OAR dose constraints, HT was found to be superior to 2 or 8-arc VMAT for optimal OAR sparing (meeting all the dose constraints (p = 0.0004. All dose constraints were met in HT plans. Increasing from 2 to 8 arcs could not help achieve optimal OAR sparing for 4 patients. 2/4 of them had 3 immediately adjacent structures. CONCLUSION: HT appears to be superior to VMAT in OAR sparing mainly in cases which require conformal dose avoidance of multiple immediately adjacent OARs. For such cases, increasing the number of arcs in VMAT cannot significantly improve OAR sparing.

  17. Can Intensity-Modulated Radiotherapy Preserve Oral Health-Related Quality of Life of Nasopharyngeal Carcinoma Patients?

    International Nuclear Information System (INIS)

    Pow, Edmond H.N.; Kwong, Dora L.W.; Sham, Jonathan S.T.; Lee, Victor H.F.; Ng, Sherry C.Y.

    2012-01-01

    Purpose: To investigate the changes in salivary function and oral health-related quality of life for patients with nasopharyngeal carcinoma treated by intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 57 patients with early-stage nasopharyngeal carcinoma received IMRT. The parotid and whole saliva flow was measured, and the Medical Outcomes Study 36-item short form, European Organization for Research and Treatment of Cancer Quality of Life questionnaire-C30, European Organization for Research and Treatment of Cancer Quality of Life questionnaire 35-item head-and-neck module, and Oral Health Impact Profile questionnaires were completed at baseline and 2, 6, 12, 18, and 24 months after IMRT. Results: Parotid saliva flow recovered fully after 1 year and maintained. Whole saliva flow recovered partially to 40% of baseline. A general trend of deterioration in most quality of life scales was observed after IMRT, followed by gradual recovery. Persistent oral-related symptoms were found 2 years after treatment. Conclusion: IMRT for early-stage nasopharyngeal carcinoma could only partially preserve the whole salivary function and oral health-related quality of life.

  18. Can Intensity-Modulated Radiotherapy Preserve Oral Health-Related Quality of Life of Nasopharyngeal Carcinoma Patients?

    Energy Technology Data Exchange (ETDEWEB)

    Pow, Edmond H.N., E-mail: ehnpow@hku.hk [Oral Rehabilitation, University of Hong Kong Faculty of Dentistry, Hong Kong Special Administrative Region (China); Kwong, Dora L.W.; Sham, Jonathan S.T.; Lee, Victor H.F.; Ng, Sherry C.Y. [Department of Clinical Oncology, University of Hong Kong Li Ka Shing Faculty of Medicine, Hong Kong Special Administrative Region (Hong Kong)

    2012-06-01

    Purpose: To investigate the changes in salivary function and oral health-related quality of life for patients with nasopharyngeal carcinoma treated by intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 57 patients with early-stage nasopharyngeal carcinoma received IMRT. The parotid and whole saliva flow was measured, and the Medical Outcomes Study 36-item short form, European Organization for Research and Treatment of Cancer Quality of Life questionnaire-C30, European Organization for Research and Treatment of Cancer Quality of Life questionnaire 35-item head-and-neck module, and Oral Health Impact Profile questionnaires were completed at baseline and 2, 6, 12, 18, and 24 months after IMRT. Results: Parotid saliva flow recovered fully after 1 year and maintained. Whole saliva flow recovered partially to 40% of baseline. A general trend of deterioration in most quality of life scales was observed after IMRT, followed by gradual recovery. Persistent oral-related symptoms were found 2 years after treatment. Conclusion: IMRT for early-stage nasopharyngeal carcinoma could only partially preserve the whole salivary function and oral health-related quality of life.

  19. Improving intensity-modulated radiation therapy using the anatomic beam orientation optimization algorithm

    International Nuclear Information System (INIS)

    Potrebko, Peter S.; McCurdy, Boyd M. C.; Butler, James B.; El-Gubtan, Adel S.

    2008-01-01

    A novel, anatomic beam orientation optimization (A-BOO) algorithm is proposed to significantly improve conventional intensity-modulated radiation therapy (IMRT). The A-BOO algorithm vectorially analyses polygonal surface mesh data of contoured patient anatomy. Five optimal (5-opt) deliverable beam orientations are selected based on (1) tangential orientation bisecting the target and adjacent organ's-at-risk (OARs) to produce precipitous dose gradients between them and (2) parallel incidence with polygon features of the target volume to facilitate conformal coverage. The 5-opt plans were compared to standard five, seven, and nine equiangular-spaced beam plans (5-equi, 7-equi, 9-equi) for: (1) gastric, (2) Radiation Therapy Oncology Group (RTOG) P-0126 prostate, and (3) RTOG H-0022 oropharyngeal (stage-III, IV) cancer patients. In the gastric case, the noncoplanar 5-opt plan reduced the right kidney V 20 Gy by 32.2%, 23.2%, and 20.6% compared to plans with five, seven, and nine equiangular-spaced beams. In the prostate case, the coplanar 5-opt plan produced similar rectal sparing as the 7-equi and 9-equi plans with a reduction of the V 75, V 70, V 65, and V 60 Gy of 2.4%, 5.3%, 7.0%, and 9.5% compared to the 5-equi plan. In the stage-III and IV oropharyngeal cases, the noncoplanar 5-opt plan substantially reduced the V 30 Gy and mean dose to the contralateral parotid compared to plans with five, seven, and nine equiangular-spaced beams: (stage-III) 7.1%, 5.2%, 6.8%, and 5.1, 3.5, 3.7 Gy and (stage-IV) 10.2%, 10.2%, 9.8% and 7.0, 7.1, 7.2 Gy. The geometry-based A-BOO algorithm has been demonstrated to be robust for application to a variety of IMRT treatment sites. Beam orientations producing significant improvements in OAR sparing over conventional IMRT can be automatically produced in minutes compared to hours with existing dose-based beam orientation optimization methods

  20. Metastatic Parotid Myoepithelial Carcinoma in a 7-Year-Old Boy

    Directory of Open Access Journals (Sweden)

    Issam Saliba

    2012-01-01

    Full Text Available Myoepithelial carcinoma is a rare malignancy of the parotid gland that is usually seen in adults. We report the first case in children of myoepithelial carcinoma of the parotid gland with massive invasion of the facial nerve and metastasis to cervical lymph nodes. Due to its rarity, the treatment and the clinical course of this tumor are not well defined yet. We performed a total parotidectomy, a modified neck dissection, and a postoperative radiotherapy in 7-year-old boy. Sparing of the facial nerve was impossible; it was sacrificed and grafted with a sural nerve. Histopathology confirmed the diagnosis of a parotid gland carcinoma and immunohistochemical markers showed that the tumor cells express cytokeratin, epithelial membrane antigen, cytokeratin 7, smooth muscle actin, P63, CEA, and S100. This pattern of immunostaining is consistent with the diagnosis of myoepithelial carcinoma. On the postoperative tenth month he presented with a pulmonary and lumbar vertebra metastasis.

  1. Xerostomia and quality of life after intensity-modulated radiotherapy vs. conventional radiotherapy for early-stage nasopharyngeal carcinoma: Initial report on a randomized controlled clinical trial

    International Nuclear Information System (INIS)

    Pow, Edmond; Kwong, Dora; McMillan, Anne S.; Wong, May; Sham, Jonathan; Leung, Lucullus; Leung, W. Keung

    2006-01-01

    Purpose: To compare directly the effect of intensity-modulated radiotherapy (IMRT) vs. conventional radiotherapy (CRT) on salivary flow and quality of life (QoL) in patients with early-stage nasopharyngeal carcinoma (NPC). Methods and Materials: Fifty-one patients with T2, N0/N1, M0 NPC took part in a randomized controlled clinical study and received IMRT or CRT. Stimulated whole (SWS) and parotid (SPS) saliva flow were measured and Medical Outcomes Short Form 36 (SF-36), European Organization for Research and Treatment of Cancer (EORTC) core quetionnaire, and EORTC head-and-neck module (QLQ-H and N35) were completed at baseline and 2, 6, and 12 months after radiotherapy. Results: Forty-six patients (88%) were in disease remission 12 months after radiotherapy. At 12 months postradiotherapy, 12 (50.0%) and 20 patients (83.3%) in the IMRT group had recovered at least 25% of preradiotherapy SWS and SPS flow respectively, compared with 1 (4.8%) and 2 patients (9.5%), respectively, in the CRT group. Global health scores showed continuous improvement in QoL after both treatments (p < 0.001). However, after 12 months subscale scores for role-physical, bodily pain, and physical function were significantly higher in the IMRT group, indicating a better condition (p < 0.05). Dry mouth and sticky saliva were problems in both groups 2 months after treatment. In the IMRT group, there was consistent improvement over time with xerostomia-related symptoms significantly less common than in the CRT group at 12 months postradiotherapy. Conclusions: IMRT was significantly better than CRT in terms of parotid sparing and improved QoL for early-stage disease. The findings support the case for assessment of health-related QoL in relation to head-and-neck cancer using a site-specific approach

  2. Fully Automated Simultaneous Integrated Boosted-Intensity Modulated Radiation Therapy Treatment Planning Is Feasible for Head-and-Neck Cancer: A Prospective Clinical Study

    Energy Technology Data Exchange (ETDEWEB)

    Wu Binbin, E-mail: binbin.wu@gunet.georgetown.edu [Department of Radiation Oncology and Molecular Radiation Science, Johns Hopkins University, Baltimore, Maryland (United States); Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States); McNutt, Todd [Department of Radiation Oncology and Molecular Radiation Science, Johns Hopkins University, Baltimore, Maryland (United States); Zahurak, Marianna [Department of Oncology Biostatistics, Johns Hopkins University, Baltimore, Maryland (United States); Simari, Patricio [Autodesk Research, Toronto, ON (Canada); Pang, Dalong [Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States); Taylor, Russell [Department of Computer Science, Johns Hopkins University, Baltimore, Maryland (United States); Sanguineti, Giuseppe [Department of Radiation Oncology and Molecular Radiation Science, Johns Hopkins University, Baltimore, Maryland (United States)

    2012-12-01

    Purpose: To prospectively determine whether overlap volume histogram (OVH)-driven, automated simultaneous integrated boosted (SIB)-intensity-modulated radiation therapy (IMRT) treatment planning for head-and-neck cancer can be implemented in clinics. Methods and Materials: A prospective study was designed to compare fully automated plans (APs) created by an OVH-driven, automated planning application with clinical plans (CPs) created by dosimetrists in a 3-dose-level (70 Gy, 63 Gy, and 58.1 Gy), head-and-neck SIB-IMRT planning. Because primary organ sparing (cord, brain, brainstem, mandible, and optic nerve/chiasm) always received the highest priority in clinical planning, the study aimed to show the noninferiority of APs with respect to PTV coverage and secondary organ sparing (parotid, brachial plexus, esophagus, larynx, inner ear, and oral mucosa). The sample size was determined a priori by a superiority hypothesis test that had 85% power to detect a 4% dose decrease in secondary organ sparing with a 2-sided alpha level of 0.05. A generalized estimating equation (GEE) regression model was used for statistical comparison. Results: Forty consecutive patients were accrued from July to December 2010. GEE analysis indicated that in APs, overall average dose to the secondary organs was reduced by 1.16 (95% CI = 0.09-2.33) with P=.04, overall average PTV coverage was increased by 0.26% (95% CI = 0.06-0.47) with P=.02 and overall average dose to the primary organs was reduced by 1.14 Gy (95% CI = 0.45-1.8) with P=.004. A physician determined that all APs could be delivered to patients, and APs were clinically superior in 27 of 40 cases. Conclusions: The application can be implemented in clinics as a fast, reliable, and consistent way of generating plans that need only minor adjustments to meet specific clinical needs.

  3. Fully Automated Simultaneous Integrated Boosted–Intensity Modulated Radiation Therapy Treatment Planning Is Feasible for Head-and-Neck Cancer: A Prospective Clinical Study

    International Nuclear Information System (INIS)

    Wu Binbin; McNutt, Todd; Zahurak, Marianna; Simari, Patricio; Pang, Dalong; Taylor, Russell; Sanguineti, Giuseppe

    2012-01-01

    Purpose: To prospectively determine whether overlap volume histogram (OVH)–driven, automated simultaneous integrated boosted (SIB)-intensity-modulated radiation therapy (IMRT) treatment planning for head-and-neck cancer can be implemented in clinics. Methods and Materials: A prospective study was designed to compare fully automated plans (APs) created by an OVH-driven, automated planning application with clinical plans (CPs) created by dosimetrists in a 3-dose-level (70 Gy, 63 Gy, and 58.1 Gy), head-and-neck SIB-IMRT planning. Because primary organ sparing (cord, brain, brainstem, mandible, and optic nerve/chiasm) always received the highest priority in clinical planning, the study aimed to show the noninferiority of APs with respect to PTV coverage and secondary organ sparing (parotid, brachial plexus, esophagus, larynx, inner ear, and oral mucosa). The sample size was determined a priori by a superiority hypothesis test that had 85% power to detect a 4% dose decrease in secondary organ sparing with a 2-sided alpha level of 0.05. A generalized estimating equation (GEE) regression model was used for statistical comparison. Results: Forty consecutive patients were accrued from July to December 2010. GEE analysis indicated that in APs, overall average dose to the secondary organs was reduced by 1.16 (95% CI = 0.09-2.33) with P=.04, overall average PTV coverage was increased by 0.26% (95% CI = 0.06-0.47) with P=.02 and overall average dose to the primary organs was reduced by 1.14 Gy (95% CI = 0.45-1.8) with P=.004. A physician determined that all APs could be delivered to patients, and APs were clinically superior in 27 of 40 cases. Conclusions: The application can be implemented in clinics as a fast, reliable, and consistent way of generating plans that need only minor adjustments to meet specific clinical needs.

  4. Dosimetric comparison of three-dimensional conformal and intensity modulated radiotherapy in brain glioma

    International Nuclear Information System (INIS)

    Lu Jie; Zhang Guifang; Bai Tong; Yin Yong; Fan Tingyong; Wu Chaoxia

    2009-01-01

    Objective: To investigate the dosimetry advantages of intensity modulated radiotherapy (IMRT)of brain glioma compared with that of three-dimensional conformal radiotherapy (SD CRT). Methods: Ten patients with brain glioma were enrolled in this study. Three-dimensional conf0rmal and intensity modulated radiotherapy plans were performed for each patient. The dose distributions of target volume and normal tissues, conformal index (CI) and heterogeneous index (HI) were analyzed using the dose-volume histogram (DVH). The prescription dose was 60 Gy in 30 fractions. Results: IMRT plans decrease the maximum dose and volume of brainstem, mean dose of affected side parotid and maximum dose of spinal-cord. The CI for PTV of IMRT was superior to that of SD CRT, the HI for PTV has no statistical significance of the two model plans. Conclusions: IMRT plans can obviously decrease the dose and volume of brainstem. IMRT is a potential method in the treatment of brain glioma, and dose escalation was possible in patients with brain glioma. (authors)

  5. Benign lymphoepithelial lesion arising in the parotid gland

    International Nuclear Information System (INIS)

    Park, Rae Chung; Choi, Soon Chul; Park, Tae Won; Yoo, Dong Soo

    1996-01-01

    The authors diagnosed a 33 years old female as benign lymphoepithelial lesion after undergoing clinical, radiological and histopathological examinations and the characteristics were as follows : 1. Clinically, the patient complained of painless bilateral swelling of the parotid glands and dryness of the palate. Rheumatoid facor was detected in her serum. 2. Sialograms showed punctuate or globular collections of contrast media distributed evenly throughout the parotid gland s in so-called 'cherry blossom' or 'fearless fruit-laden tree' appearance. 3. A salivary gland scan showed no uptake of radioisotopes by the parotid glands. 4. At T1-weighted imaging of PNS MRI, the lesions had the same signal intensity as the rest of the gland. At T2-weighted imaging, the lesion could be seen as high signal intensity 1.3 cm and 2.1 cm in diameter in the left and the right parotid gland respectively. 5. Ultrasonogram showed sonolucent lesions 20 X 15 mm and 17 X 14 mm in size in the lower part of the left parotid gland an d another 18 X 11 mm in size in the lower part of the parotid gland AS well as many other small sonolucent lesions. 6. Histopathologically, lymphocytic infiltration replacing the normal acini and lymphoid follicles containing germinal centers could be seen. Epimyoepithelial islands were scattered throughout the lesion and benign lymphoepithelial cysts were also observed.

  6. The use of intensity-modulated radiation therapy photon beams for improving the dose uniformity of electron beams shaped with MLC.

    Science.gov (United States)

    Mosalaei, Homeira; Karnas, Scott; Shah, Sheel; Van Doodewaard, Sharon; Foster, Tim; Chen, Jeff

    2012-01-01

    Electrons are ideal for treating shallow tumors and sparing adjacent normal tissue. Conventionally, electron beams are collimated by cut-outs that are time-consuming to make and difficult to adapt to tumor shape throughout the course of treatment. We propose that electron cut-outs can be replaced using photon multileaf collimator (MLC). Two major problems of this approach are that the scattering of electrons causes penumbra widening because of a large air gap, and available commercial treatment planning systems (TPSs) do not support MLC-collimated electron beams. In this study, these difficulties were overcome by (1) modeling electron beams collimated by photon MLC for a commercial TPS, and (2) developing a technique to reduce electron beam penumbra by adding low-energy intensity-modulated radiation therapy (IMRT) photons (4 MV). We used blocks to simulate MLC shielding in the TPS. Inverse planning was used to optimize boost photon beams. This technique was applied to a parotid and a central nervous system (CNS) clinical case. Combined photon and electron plans were compared with conventional plans and verified using ion chamber, film, and a 2D diode array. Our studies showed that the beam penumbra for mixed beams with 90 cm source to surface distance (SSD) is comparable with electron applicators and cut-outs at 100 cm SSD. Our mixed-beam technique yielded more uniform dose to the planning target volume and lower doses to various organs at risk for both parotid and CNS clinical cases. The plans were verified with measurements, with more than 95% points passing the gamma criteria of 5% in dose difference and 5 mm for distance to agreement. In conclusion, the study has demonstrated the feasibility and potential advantage of using photon MLC to collimate electron beams with boost photon IMRT fields. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  7. Fan-beam intensity modulated proton therapy.

    Science.gov (United States)

    Hill, Patrick; Westerly, David; Mackie, Thomas

    2013-11-01

    This paper presents a concept for a proton therapy system capable of delivering intensity modulated proton therapy using a fan beam of protons. This system would allow present and future gantry-based facilities to deliver state-of-the-art proton therapy with the greater normal tissue sparing made possible by intensity modulation techniques. A method for producing a divergent fan beam of protons using a pair of electromagnetic quadrupoles is described and particle transport through the quadrupole doublet is simulated using a commercially available software package. To manipulate the fan beam of protons, a modulation device is developed. This modulator inserts or retracts acrylic leaves of varying thickness from subsections of the fan beam. Each subsection, or beam channel, creates what effectively becomes a beam spot within the fan area. Each channel is able to provide 0-255 mm of range shift for its associated beam spot, or stop the beam and act as an intensity modulator. Results of particle transport simulations through the quadrupole system are incorporated into the MCNPX Monte Carlo transport code along with a model of the range and intensity modulation device. Several design parameters were investigated and optimized, culminating in the ability to create topotherapy treatment plans using distal-edge tracking on both phantom and patient datasets. Beam transport calculations show that a pair of electromagnetic quadrupoles can be used to create a divergent fan beam of 200 MeV protons over a distance of 2.1 m. The quadrupole lengths were 30 and 48 cm, respectively, with transverse field gradients less than 20 T/m, which is within the range of water-cooled magnets for the quadrupole radii used. MCNPX simulations of topotherapy treatment plans suggest that, when using the distal edge tracking delivery method, many delivery angles are more important than insisting on narrow beam channel widths in order to obtain conformal target coverage. Overall, the sharp distal

  8. Improved normal tissue sparing in head and neck radiotherapy using biological cost function based-IMRT.

    Science.gov (United States)

    Anderson, N; Lawford, C; Khoo, V; Rolfo, M; Joon, D L; Wada, M

    2011-12-01

    Intensity-modulated radiotherapy (IMRT) has reduced the impact of acute and late toxicities associated with head and neck radiotherapy. Treatment planning system (TPS) advances in biological cost function based optimization (BBO) and improved segmentation techniques have increased organ at risk (OAR) sparing compared to conventional dose-based optimization (DBO). A planning study was undertaken to compare OAR avoidance in DBO and BBO treatment planning. Simultaneous integrated boost treatment plans were produced for 10 head and neck patients using both planning systems. Plans were compared for tar get coverage and OAR avoidance. Comparisons were made using the BBO TPS Monte Carlo dose engine to eliminate differences due to inherent algorithms. Target coverage (V95%) was maintained for both solutions. BBO produced lower OAR doses, with statistically significant improvement to left (12.3%, p = 0.005) and right parotid mean dose (16.9%, p = 0.004), larynx V50_Gy (71.0%, p = 0.005), spinal cord (21.9%, p < 0.001) and brain stem dose maximums (31.5%, p = 0.002). This study observed improved OAR avoidance with BBO planning. Further investigations will be undertaken to review any clinical benefit of this improved planned dosimetry.

  9. Hippocampus sparing in whole-brain radiotherapy. A review

    International Nuclear Information System (INIS)

    Oskan, F.; Ganswindt, U.; Schwarz, S.B.; Manapov, F.; Belka, C.; Niyazi, M.

    2014-01-01

    Radiation treatment techniques for whole-brain radiation therapy (WBRT) have not changed significantly since development of the procedure. However, the recent development of novel techniques such as intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT) and helical tomotherapy, as well as an increasing body of evidence concerning neural stem cells (NSCs) have altered the conventional WBRT treatment paradigm. In this regard, hippocampus-sparing WBRT is a novel technique that aims to spare critical hippocampus regions without compromising tumour control. Published data on this new technique are limited to planning and feasibility studies; data on patient outcome are still lacking. However, several prospective trials to analyse the feasibility of this technique and to document clinical outcome in terms of reduced neurotoxicity are ongoing. (orig.) [de

  10. Long-Term Quality of Life After Swallowing and Salivary-Sparing Chemo–Intensity Modulated Radiation Therapy in Survivors of Human Papillomavirus–Related Oropharyngeal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vainshtein, Jeffrey M. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Moon, Dominic H. [University of Michigan Medical School, Ann Arbor, Michigan (United States); Feng, Felix Y. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Chepeha, Douglas B. [Department of Otolaryngology—Head and Neck Surgery, University of Michigan, Ann Arbor, Michigan (United States); Eisbruch, Avraham, E-mail: eisbruch@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Stenmark, Matthew H. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2015-04-01

    Purpose: To evaluate long-term health-related quality of life (HRQOL) in 2 prospective studies of chemo–intensity modulated radiation therapy (chemo-IMRT) for oropharyngeal cancer (OPC). Methods and Materials: Of 93 patients with stage III/IV OPC treated on prospective studies of swallowing and salivary organ-sparing chemo-IMRT, 69 were eligible for long-term HRQOL assessment. Three validated patient-reported instruments, the Head and Neck QOL (HNQOL) questionnaire, the University of Washington quality of life (UWQOL) questionnaire, and the Xerostomia Questionnaire (XQ), previously administered from baseline through 2 years in the parent studies, were readministered at long-term follow-up, along with the Short-Form 36. Long-term changes in HRQOL from before treatment and 2 years were evaluated. Results: Forty patients (58%) with a median follow-up of 6.5 years participated, 39 of whom (97.5%) had confirmed human papillomavirus–positive OPC. Long term, no clinically significant worsening was detected in mean HRQOL scores compared with 2 years, with stable or improved HRQOL from before treatment in nearly all domains. “Moderate” or greater severity problems were uncommon, reported by 5% of patients for eating, 5% for swallowing, and 2.5% and 5% by HNQOL and UWQOL summary scores, respectively. Freedom from percutaneous endoscopic gastrostomy tube dependence and stricture dilation beyond 2 years was 97.5% and 95%, respectively. Eleven percent and 14% of patients reported “moderate” or “severe” long-term worsening in HNQOL Pain and Overall Bother domains, respectively, which were associated with mean dose to the cervical esophagus, larynx, and pharyngeal constrictors. Conclusions: At more than 6 years' median follow-up, OPC patients treated with swallowing and salivary organ-sparing chemo-IMRT reported stable or improved HRQOL in nearly all domains compared with both before treatment and 2-year follow-up. New late toxicity after 2 years was

  11. A comparison of mean parotid gland dose with measures of parotid gland function after radiotherapy for head-and-neck cancer: Implications for future trials

    International Nuclear Information System (INIS)

    Roesink, Judith M.; Schipper, Maria; Busschers, Wim; Raaijmakers, Cornelis P.J.; Terhaard, Chris H.J.

    2005-01-01

    Purpose: To determine the most adequate parameter to measure the consequences of reducing the parotid gland dose. Methods and Materials: One hundred eight patients treated with radiotherapy for various malignancies of the head and neck were prospectively evaluated using three methods. Parotid gland function was objectively determined by measuring stimulated parotid flow using Lashley cups and scintigraphy. To assess xerostomia-related quality of life, the head-and-neck cancer module European Organization for Research and Treatment of Cancer QLQ (Quality of Life Questionnaire) H and N35 was used. Measurements took place before radiotherapy and 6 weeks and 12 months after the completion of radiotherapy. Complication was defined for each method using cutoff values. The correlation between these complications and the mean parotid gland dose was investigated to find the best measure for parotid gland function. Results: For both flow and scintigraphy data, the best definition for objective parotid gland toxicity seemed to be reduction of stimulated parotid flow to ≤25% of the preradiotherapy flow. Of all the subjective variables, only the single item dry mouth 6 weeks after radiotherapy was found to be significant. The best correlation with the mean parotid gland dose was found for the stimulated flow measurements. The predictive ability was the highest for the time point 1 year after radiotherapy. Subjective findings did not correlate with the mean parotid dose. Conclusions: Stimulated flow measurements using Lashley cups, with a complication defined as flow ≤25% of the preradiotherapy output, correlated best with the mean parotid gland dose. When reduction of the mean dose to the parotid gland is intended, the stimulated flow measurement is the best method for evaluating parotid gland function

  12. Is it necessary to repeat CT imaging and replanning during the course of intensity-modulated radiation therapy for locoregionally advanced nasopharyngeal carcinoma?

    International Nuclear Information System (INIS)

    Chen Chuanben; Lin Xiang; Pan Jianji; Fei Zhaodong; Chen Lisha; Bai Penggang

    2013-01-01

    Our aim was to evaluate the volumetric and dosimetric changes of target volumes and organs at risk (OARs) during intensity-modulated radiation therapy (IMRT) for locoregionally advanced nasopharyngeal carcinoma (NPC) and the necessity of replanning. Twenty locoregionally advanced NPC patients treated by concurrent chemotherapy and IMRT were included. CT and MR images were acquired before treatment and at weeks 2, 3, 4, 5 and 6 during treatment. The target volumes and OARs were contoured based on the fused CT-MRI images and hybrid plans were generated. The changes of volume and dosimetry were measured by comparing original plan and hybrid plans. Significant volumetric changes of target volumes and parotid gland were observed. The primary nasopharyngeal tumor (GTVnx), clinical target volume 1 (CTV1), involved lymph nodes (GTVnd) and left and right parotid glands, shrank at a mean rate of 14.7, 11.56, 11.40, 6.54 and 6.78% per treatment week, respectively. There were no significant dosimetric changes in GTVnx, GTVnd, CTV1, spinal cord and brain stem while the differences of dose to left and right parotid glands were significant (F=6.73, P=0.007; F=7.43, P=0.007). Remarkable volumetric changes were observed. However, the dosimetric changes were inconspicuous except for the parotid. Replanning might contribute to protect the parotid gland. (author)

  13. Intensity modulated radiotherapy for sinonasal malignancies with a focus on optic pathway preservation

    Directory of Open Access Journals (Sweden)

    Chi Alexander

    2013-01-01

    Full Text Available Abstract Purpose To assess if intensity-modulated radiotherapy (IMRT can possibly lead to improved local control and lower incidence of vision impairment/blindness in comparison to non-IMRT techniques when treating sinonasal malignancies; what is the most optimal dose constraints for the optic pathway; and the impact of different IMRT strategies on optic pathway sparing in this setting. Methods and materials A literature search in the PubMed databases was conducted in July, 2012. Results Clinical studies on IMRT and 2D/3D (2 dimensional/3 dimensional RT for sinonasal malignancies suggest improved local control and lower incidence of severe vision impairment with IMRT in comparison to non-IMRT techniques. As observed in the non-IMRT studies, blindness due to disease progression may occur despite a lack of severe toxicity possibly due to the difficulty of controlling locally very advanced disease with a dose ≤ 70 Gy. Concurrent chemotherapy’s influence on the the risk of severe optic toxicity after radiotherapy is unclear. A maximum dose of ≤ 54 Gy with conventional fractionation to the optic pathway may decrease the risk of blindness. Increased magnitude of intensity modulation through increasing the number of segments, beams, and using a combination of coplanar and non-coplanar arrangements may help increase dose conformality and optic pathway sparing when IMRT is used. Conclusion IMRT optimized with appropriate strategies may be the treatment of choice for the most optimal local control and optic pathway sparing when treating sinonasal malignancy.

  14. 3D-FIESTA MRI at 3 T demonstrating branches of the intraparotid facial nerve, parotid ducts and relation with benign parotid tumours

    International Nuclear Information System (INIS)

    Li Chuanting; Li Yan; Zhang Dongsheng; Yang Zhenzhen; Wu Lebin

    2012-01-01

    Aim: To investigate the usefulness of three-dimensional (3D) fast imaging employing steady state precession (FIESTA) magnetic resonance imaging (MRI) at 3 T in evaluating the intraparotid components of the facial nerve and parotid ducts, and to compare the MRI images with surgical findings. Materials and methods: Thirty-one cases of benign parotid tumours were studied with conventional and 3D FIESTA MRI sequences at 3T using a head coil. The most clinically useful 3D FIESTA images were acquired at parameters of 4.9 ms repetition time (TR); 1.5 effective echo time (TEeff); a flip of 55°, a field of view of 18 to 20 cm, a matrix of 512 × 320, an axial plane, no gaps, and a section thickness of 1 mm. Post-processed multiplanar images were obtained with an Advantage Windows (AW sdc 4.3) workstation. Parotid ducts, facial nerves, and tumours were identified on these images. The relationship of the tumours to the facial nerves and parotid ducts was confirmed at surgery. Results: The facial nerves appeared as linear structures of low intensity. The main trunk of the facial nerve was identified bilaterally in 93.5% of the 3D-FIESTA sequence images. Parotid ducts appeared as structures of high intensity on multiplanar 3D-FIESTA images (100%). The relationships of the tumours with the cervicofacial and temporofacial divisions of the facial nerve were correctly diagnosed in 26 of 31 cases (83.9%) using 3D-FIESTA sequence images. Conclusion: 3D-FIESTA MRI at 3 T depicted the main trunk, cervicofacial and temporofacial divisions of the facial nerve, and the main parotid duct. It is useful for preoperative evaluation of parotid gland tumours.

  15. Chemoradioprotection of the rat parotid gland by the beta-sympathomimetic agonist, terbutaline

    International Nuclear Information System (INIS)

    Sinesi, M.S.

    1981-01-01

    The present study demonstrates the effectiveness of the beta-adrenergic stimulator known as terbutaline in providing increased radioresistance to the normal, (i.e. nonmalignant) rat parotid salivary gland. Radiation damage was assessed by gland weight and microscopic examination of saline-treated and terbutaline-treated groups during days 1 to 10 and at 60 days post-irradiation. Terbutaline-treated groups exhibited both a sparing of gland weight loss as well as better preservation of glandular microstructure at all periods examined post-irradiation. Radioprotection of human parotid glands would provide relief from the xerostomia and its severe sequelae which often follow radiotherapy to the head and neck region in cancer patients. Terbutaline, with its preferential affinity for the beta-2 adrenergic receptor may provide a therapeutic advantage without the cardiac effects which normally accompany less specific (beta-1 + beta-2) adrenergic stimulation. In addition to providing a model for clinical protection of the salivary glands, this demonstration of protection of the rat parotid may also serve as a model for investigation of the mechanisms of action of terbutaline and other radioprotective compounds

  16. Recommendation for a contouring method and atlas of organs at risk in nasopharyngeal carcinoma patients receiving intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Sun, Ying; Yu, Xiao-Li; Luo, Wei; Lee, Anne W.M.; Wee, Joseph Tien Seng; Lee, Nancy; Zhou, Guan-Qun; Tang, Ling-Long; Tao, Chang-Juan; Guo, Rui; Mao, Yan-Ping; Zhang, Rong; Guo, Ying; Ma, Jun

    2014-01-01

    Background and purpose: To recommend contouring methods and atlas of organs at risk (OARs) for nasopharyngeal carcinoma (NPC) patients receiving intensity-modulated radiotherapy, in order to help reach a consensus on interpretations of OARs delineation. Methods and materials: Two to four contouring methods for the middle ear, inner ear, temporal lobe, parotid gland and spinal cord were identified via systematic literature review; their volumes and dosimetric parameters were compared in 41 patients. Areas under the receiver operating characteristic curves for temporal lobe contouring were compared in 21 patients with unilateral temporal lobe necrosis (TLN). Results: Various contouring methods for the temporal lobe, middle ear, inner ear, parotid gland and spinal cord lead to different volumes and dosimetric parameters (P < 0.05). For TLN, D1 of PRV was the most relevant dosimetric parameter and 64 Gy was the critical point. We suggest contouring for the temporal lobe, middle ear, inner ear, parotid gland and spinal cord. A CT–MRI fusion atlas comprising 33 OARs was developed. Conclusions: Different dosimetric parameters may hinder the dosimetric research. The present recommendation and atlas, may help reach a consensus on subjective interpretation of OARs delineation to reduce inter-institutional differences in NPC patients

  17. Intensity-Modulated Radiotherapy for Craniospinal Irradiation: Target Volume Considerations, Dose Constraints, and Competing Risks

    International Nuclear Information System (INIS)

    Parker, William; Filion, Edith; Roberge, David; Freeman, Carolyn R.

    2007-01-01

    Purpose: To report the results of an analysis of dose received to tissues and organs outside the target volume, in the setting of spinal axis irradiation for the treatment of medulloblastoma, using three treatment techniques. Methods and Materials: Treatment plans (total dose, 23.4 Gy) for a standard two-dimensional (2D) technique, a three-dimensional (3D) technique using a 3D imaging-based target volume, and an intensity-modulated radiotherapy (IMRT) technique, were compared for 3 patients in terms of dose-volume statistics for target coverage, as well as organ at risk (OAR) and overall tissue sparing. Results: Planning target volume coverage and dose homogeneity was superior for the IMRT plans for V 95% (IMRT, 100%; 3D, 96%; 2D, 98%) and V 107% (IMRT, 3%; 3D, 38%; 2D, 37%). In terms of OAR sparing, the IMRT plan was better for all organs and whole-body contour when comparing V 10Gy , V 15Gy , and V 20Gy . The 3D plan was superior for V 5Gy and below. For the heart and liver in particular, the IMRT plans provided considerable sparing in terms of V 10Gy and above. In terms of the integral dose, the IMRT plans were superior for liver (IMRT, 21.9 J; 3D, 28.6 J; 2D, 38.6 J) and heart (IMRT, 9 J; 3D, 14.1J; 2D, 19.4 J), the 3D plan for the body contour (IMRT, 349 J; 3D, 337 J; 2D, 555 J). Conclusions: Intensity-modulated radiotherapy is a valid treatment option for spinal axis irradiation. We have shown that IMRT results in sparing of organs at risk without a significant increase in integral dose

  18. Adjuvant intensity-modulated proton therapy in malignant pleural mesothelioma. A comparison with intensity-modulated radiotherapy and a spot size variation assessment

    Energy Technology Data Exchange (ETDEWEB)

    Lorentini, S. [Agenzia Provinciale per la Protonterapia (ATreP), Trento (Italy); Padova Univ. (Italy). Medical Physics School; Amichetti, M.; Fellin, F.; Schwarz, M. [Agenzia Provinciale per la Protonterapia (ATreP), Trento (Italy); Spiazzi, L. [Brescia Hospital (Italy). Medical Physics Dept.; Tonoli, S.; Magrini, S.M. [Brescia Hospital (Italy). Radiation Oncology Dept.

    2012-03-15

    Intensity-modulated radiation therapy (IMRT) is the state-of-the-art treatment for patients with malignant pleural mesothelioma (MPM). The goal of this work was to assess whether intensity-modulated proton therapy (IMPT) could further improve the dosimetric results allowed by IMRT. We re-planned 7 MPM cases using both photons and protons, by carrying out IMRT and IMPT plans. For both techniques, conventional dose comparisons and normal tissue complication probability (NTCP) analysis were performed. In 3 cases, additional IMPT plans were generated with different beam dimensions. IMPT allowed a slight improvement in target coverage and clear advantages in dose conformity (p < 0.001) and dose homogeneity (p = 0.01). Better organ at risk (OAR) sparing was obtained with IMPT, in particular for the liver (D{sub mean} reduction of 9.5 Gy, p = 0.001) and ipsilateral kidney (V{sub 20} reduction of 58%, p = 0.001), together with a very large reduction of mean dose for the contralateral lung (0.2 Gy vs 6.1 Gy, p = 0.0001). NTCP values for the liver showed a systematic superiority of IMPT with respect to IMRT for both the esophagus (average NTCP 14% vs. 30.5%) and the ipsilateral kidney (p = 0.001). Concerning plans obtained with different spot dimensions, a slight loss of target coverage was observed along with sigma increase, while maintaining OAR irradiation always under planning constraints. Results suggest that IMPT allows better OAR sparing with respect to IMRT, mainly for the liver, ipsilateral kidney, and contralateral lung. The use of a spot dimension larger than 3 x 3 mm (up to 9 x 9 mm) does not compromise dosimetric results and allows a shorter delivery time.

  19. Actual Dose Variation of Parotid Glands and Spinal Cord for Nasopharyngeal Cancer Patients During Radiotherapy

    International Nuclear Information System (INIS)

    Han Chunhui; Chen Yijen; Liu An; Schultheiss, Timothy E.; Wong, Jeffrey Y.C.

    2008-01-01

    Purpose: For intensity-modulated radiotherapy of nasopharyngeal cancer, accurate dose delivery is crucial to the success of treatment. This study aimed to evaluate the significance of daily image-guided patient setup corrections and to quantify the parotid gland volume and dose variations for nasopharyngeal cancer patients using helical tomotherapy megavoltage computed tomography (CT). Methods and Materials: Five nasopharyngeal cancer patients who underwent helical tomotherapy were selected retrospectively. Each patient had received 70 Gy in 35 fractions. Daily megavoltage CT scans were registered with the planning CT images to correct the patient setup errors. Contours of the spinal cord and parotid glands were drawn on the megavoltage CT images at fixed treatment intervals. The actual doses delivered to the critical structures were calculated using the helical tomotherapy Planned Adaptive application. Results: The maximal dose to the spinal cord showed a significant increase and greater variation without daily setup corrections. The significant decrease in the parotid gland volume led to a greater median dose in the later phase of treatment. The average parotid gland volume had decreased from 20.5 to 13.2 cm 3 by the end of treatment. On average, the median dose to the parotid glands was 83 cGy and 145 cGy for the first and the last treatment fractions, respectively. Conclusions: Daily image-guided setup corrections can eliminate significant dose variations to critical structures. Constant monitoring of patient anatomic changes and selective replanning should be used during radiotherapy to avoid critical structure complications

  20. Dose Sparing of Brainstem and Spinal Cord for Re-Irradiating Recurrent Head and Neck Cancer with Intensity-Modulated Radiotherapy

    International Nuclear Information System (INIS)

    Chen, Chin-Cheng; Lee, Chen-Chiao; Mah, Dennis; Sharma, Rajiv; Landau, Evan; Garg, Madhur; Wu, Andrew

    2011-01-01

    Because of the dose limit for critical structures such as brainstem and spinal cord, administering a dose of 60 Gy to patients with recurrent head and neck cancer is challenging for those who received a previous dose of 60-70 Gy. Specifically, previously irradiated head and neck patients may have received doses close to the tolerance limit to their brainstem and spinal cord. In this study, a reproducible intensity-modulated radiation therapy (IMRT) treatment design is presented to spare the doses to brainstem and spinal cord, with no compromise of prescribed dose delivery. Between July and November 2008, 7 patients with previously irradiated, recurrent head and neck cancers were treated with IMRT. The jaws of each field were set fixed with the goal of shielding the brainstem and spinal cord at the sacrifice of partial coverage of the planning target volume (PTV) from any particular beam orientation. Beam geometry was arranged to have sufficient coverage of the PTV and ensure that the constraints of spinal cord o , patients could be treated by 18 fields. Six patients met these criteria and were treated in 25 minutes per fraction. One patient exceeded a 30 o Cobb's angle and was treated by 31 fields in 45 minutes per fraction. We have demonstrated a new technique for retreatment of head and neck cancers. The angle of cervical spine curvature plays an important role in the efficiency and effectiveness of our approach.

  1. Intensity modulated radiotherapy for breast cancer

    International Nuclear Information System (INIS)

    Riou, O.; Fenoglietto, P.; Lemanski, C.; Azria, D.

    2012-01-01

    Intensity modulated radiotherapy (IMRT) is a technique allowing dose escalation and normal tissue sparing for various cancer types. For breast cancer, the main goals when using IMRT were to improve dose homogeneity within the breast and to enhance coverage of complex target volumes. Nonetheless, better heart and lung protections are achievable with IMRT as compared to standard irradiation for difficult cases. Three prospective randomized controlled trials of IMRT versus standard treatment showed that a better breast homogeneity can translate into better overall cosmetic results. Dosimetric and clinical studies seem to indicate a benefit of IMRT for lymph nodes irradiation, bilateral treatment, left breast and chest wall radiotherapy, or accelerated partial breast irradiation. The multiple technical IMRT solutions available tend to indicate a widespread use for breast irradiation. Nevertheless, indications for breast IMRT should be personalized and selected according to the expected benefit for each individual. (authors)

  2. MR imaging of the parotid gland following sialography

    International Nuclear Information System (INIS)

    Nakano, Y.; Nishimura, K.; Togashi, K.; Itoh, K.; Fujisawa, I.; Itoh, H.; Abe, M.; Torizuka, K.; Naito, Y.

    1986-01-01

    MR imaging was performed after sialography (using 76% Renografin) in eight patients with parotid tumor. MR imaging was performed at 1.5 T and using 16-cm-diameter surface coil and a pulse sequence of 600/25 msec. The ductal system and periductal interstitial space consistently appeared as a linear low-intensity band. MR images of two rabbits that had received parotid gland injections of 76% Renografin confirmed that the low-intensity signal arose from the edema fluid in the periductal interstitial space of the gland. Since the facial nerve follows a course immediately lateral to the major duct, an appreciation of the course of the facial nerve may allow more precise presurgical planning

  3. Parotid gland mean dose as a xerostomia predictor in low-dose domains.

    Science.gov (United States)

    Gabryś, Hubert Szymon; Buettner, Florian; Sterzing, Florian; Hauswald, Henrik; Bangert, Mark

    2017-09-01

    Xerostomia is a common side effect of radiotherapy resulting from excessive irradiation of salivary glands. Typically, xerostomia is modeled by the mean dose-response characteristic of parotid glands and prevented by mean dose constraints to either contralateral or both parotid glands. The aim of this study was to investigate whether normal tissue complication probability (NTCP) models based on the mean radiation dose to parotid glands are suitable for the prediction of xerostomia in a highly conformal low-dose regime of modern intensity-modulated radiotherapy (IMRT) techniques. We present a retrospective analysis of 153 head and neck cancer patients treated with radiotherapy. The Lyman Kutcher Burman (LKB) model was used to evaluate predictive power of the parotid gland mean dose with respect to xerostomia at 6 and 12 months after the treatment. The predictive performance of the model was evaluated by receiver operating characteristic (ROC) curves and precision-recall (PR) curves. Average mean doses to ipsilateral and contralateral parotid glands were 25.4 Gy and 18.7 Gy, respectively. QUANTEC constraints were met in 74% of patients. Mild to severe (G1+) xerostomia prevalence at both 6 and 12 months was 67%. Moderate to severe (G2+) xerostomia prevalence at 6 and 12 months was 20% and 15%, respectively. G1 + xerostomia was predicted reasonably well with area under the ROC curve ranging from 0.69 to 0.76. The LKB model failed to provide reliable G2 + xerostomia predictions at both time points. Reduction of the mean dose to parotid glands below QUANTEC guidelines resulted in low G2 + xerostomia rates. In this dose domain, the mean dose models predicted G1 + xerostomia fairly well, however, failed to recognize patients at risk of G2 + xerostomia. There is a need for the development of more flexible models able to capture complexity of dose response in this dose regime.

  4. Intensity-Modulated Radiation Therapy for Primary Brain Tumors

    Institute of Scientific and Technical Information of China (English)

    Zhong-min Wang

    2004-01-01

    Radiation therapy has been used to treat primary brain tumors as standard primary and/or adjunctive therapies for decades. It is difficult for conventional radiotherapy to deliver a lethal dose of radiation to the tumors while sparing surrounding normal brain due to complicated structures and multifunction in human brain. With the understanding of radiation physics and computer technology, a number of novel and more precise radiotherapies have been developed in recent years. Intensity modulated radiotherapy (IMRT) is one of these strategies. The use of IMRT in the treatment of primary brain tumors is being increasing nowadays. It shows great promise for some of primary brain tumors and also presents some problems, This review highlights current IMRT in the treatment of mainly primary brain tumors.

  5. Lack of Osteoradionecrosis of the Mandible After Intensity-Modulated Radiotherapy for Head and Neck Cancer: Likely Contributions of Both Dental Care and Improved Dose Distributions

    International Nuclear Information System (INIS)

    Ben-David, Merav A.; Diamante, Maximiliano; Radawski, Jeffrey D.; Vineberg, Karen A.; Stroup, Cynthia; Murdoch-Kinch, Carol-Anne; Zwetchkenbaum, Samuel R.; Eisbruch, Avraham

    2007-01-01

    Purpose: To assess the prevalence and dosimetric and clinical predictors of mandibular osteoradionecrosis (ORN) in patients with head and neck cancer who underwent a pretherapy dental evaluation and prophylactic treatment according to a uniform policy and were treated with intensity-modulated radiotherapy (IMRT). Methods and Materials: Between 1996 and 2005, all patients with head-and-neck cancer treated with parotid gland-sparing IMRT in prospective studies underwent a dental examination and prophylactic treatment according to a uniform policy that included extractions of high-risk, periodontally involved, and nonrestorable teeth in parts of the mandible expected to receive high radiation doses, fluoride supplements, and the placement of guards aiming to reduce electron backscatter off metal teeth restorations. The IMRT plans included dose constraints for the maximal mandibular doses and reduced mean parotid gland and noninvolved oral cavity doses. A retrospective analysis of Grade 2 or worse (clinical) ORN was performed. Results: A total of 176 patients had a minimal follow-up of 6 months. Of these, 31 (17%) had undergone teeth extractions before RT and 13 (7%) after RT. Of the 176 patients, 75% and 50% had received ≥65 Gy and ≥70 Gy to ≥1% of the mandibular volume, respectively. Falloff across the mandible characterized the dose distributions: the average gradient (in the axial plane containing the maximal mandibular dose) was 11 Gy (range, 1-27 Gy; median, 8 Gy). At a median follow-up of 34 months, no cases of ORN had developed (95% confidence interval, 0-2%). Conclusion: The use of a strict prophylactic dental care policy and IMRT resulted in no case of clinical ORN. In addition to the dosimetric advantages offered by IMRT, meticulous dental prophylactic care is likely an essential factor in reducing ORN risk

  6. SU-E-T-309: Dosimetric Comparison of Simultaneous Integrated Boost Treatment Plan Between Intensity Modulated Radiotherapies (IMRTs), Dual Arc Volumetric Modulated Arc Therapy (DA-VMAT) and Single Arc Volumetric Modulated Arc Therapy (SA-VMAT) for Nasopharyngeal Carcinoma (NPC)

    International Nuclear Information System (INIS)

    Sivakumar, R; Janardhan, N; Bhavani, P; Surendran, J; Saranganathan, B; Ibrahim, S; Jhonson, B; Madhuri, B; Anuradha, C

    2015-01-01

    Purpose: To compare the plan quality and performance of Simultaneous Integrated Boost (SIB) Treatment plan between Seven field (7F) and Nine field(9F) Intensity Modulated Radiotherapies and Single Arc (SA) and Dual Arc (DA) Volumetric Modulated Arc Therapy( VMAT). Methods: Retrospective planning study of 16 patients treated in Elekta Synergy Platform (mlci2) by 9F-IMRT were replanned with 7F-IMRT, Single Arc VMAT and Dual Arc VMAT using CMS, Monaco Treatment Planning System (TPS) with Monte Carlo simulation. Target delineation done as per Radiation Therapy Oncology Protocols (RTOG 0225&0615). Dose Prescribed as 70Gy to Planning Target Volumes (PTV70) and 61Gy to PTV61 in 33 fraction as a SIB technique. Conformity Index(CI), Homogeneity Index(HI) were used as analysis parameter for Target Volumes as well as Mean dose and Max dose for Organ at Risk(OAR,s).Treatment Delivery Time(min), Monitor unit per fraction (MU/fraction), Patient specific quality assurance were also analysed. Results: A Poor dose coverage and Conformity index (CI) was observed in PTV70 by 7F-IMRT among other techniques. SA-VMAT achieved poor dose coverage in PTV61. No statistical significance difference observed in OAR,s except Spinal cord (P= 0.03) and Right optic nerve (P=0.03). DA-VMAT achieved superior target coverage, higher CI (P =0.02) and Better HI (P=0.03) for PTV70 other techniques (7F-IMRT/9F-IMRT/SA-VMAT). A better dose spare for Parotid glands and spinal cord were seen in DA-VMAT. The average treatment delivery time were 5.82mins, 6.72mins, 3.24mins, 4.3mins for 7F-IMRT, 9F-IMRT, SA-VMAT and DA-VMAT respectively. Significance difference Observed in MU/fr (P <0.001) and Patient quality assurance pass rate were >95% (Gamma analysis (Γ3mm, 3%). Conclusion: DA-VAMT showed better target dose coverage and achieved better or equal performance in sparing OARs among other techniques. SA-VMAT offered least Treatment Time than other techniques but achieved poor target coverage. DA-VMAT offered

  7. SU-E-T-309: Dosimetric Comparison of Simultaneous Integrated Boost Treatment Plan Between Intensity Modulated Radiotherapies (IMRTs), Dual Arc Volumetric Modulated Arc Therapy (DA-VMAT) and Single Arc Volumetric Modulated Arc Therapy (SA-VMAT) for Nasopharyngeal Carcinoma (NPC)

    Energy Technology Data Exchange (ETDEWEB)

    Sivakumar, R; Janardhan, N; Bhavani, P; Surendran, J; Saranganathan, B; Ibrahim, S; Jhonson, B; Madhuri, B [Omega Hospitals, Hyderabad, Telangana (India); Anuradha, C [Vit University, Vellore, Tamil Nadu (India)

    2015-06-15

    Purpose: To compare the plan quality and performance of Simultaneous Integrated Boost (SIB) Treatment plan between Seven field (7F) and Nine field(9F) Intensity Modulated Radiotherapies and Single Arc (SA) and Dual Arc (DA) Volumetric Modulated Arc Therapy( VMAT). Methods: Retrospective planning study of 16 patients treated in Elekta Synergy Platform (mlci2) by 9F-IMRT were replanned with 7F-IMRT, Single Arc VMAT and Dual Arc VMAT using CMS, Monaco Treatment Planning System (TPS) with Monte Carlo simulation. Target delineation done as per Radiation Therapy Oncology Protocols (RTOG 0225&0615). Dose Prescribed as 70Gy to Planning Target Volumes (PTV70) and 61Gy to PTV61 in 33 fraction as a SIB technique. Conformity Index(CI), Homogeneity Index(HI) were used as analysis parameter for Target Volumes as well as Mean dose and Max dose for Organ at Risk(OAR,s).Treatment Delivery Time(min), Monitor unit per fraction (MU/fraction), Patient specific quality assurance were also analysed. Results: A Poor dose coverage and Conformity index (CI) was observed in PTV70 by 7F-IMRT among other techniques. SA-VMAT achieved poor dose coverage in PTV61. No statistical significance difference observed in OAR,s except Spinal cord (P= 0.03) and Right optic nerve (P=0.03). DA-VMAT achieved superior target coverage, higher CI (P =0.02) and Better HI (P=0.03) for PTV70 other techniques (7F-IMRT/9F-IMRT/SA-VMAT). A better dose spare for Parotid glands and spinal cord were seen in DA-VMAT. The average treatment delivery time were 5.82mins, 6.72mins, 3.24mins, 4.3mins for 7F-IMRT, 9F-IMRT, SA-VMAT and DA-VMAT respectively. Significance difference Observed in MU/fr (P <0.001) and Patient quality assurance pass rate were >95% (Gamma analysis (Γ3mm, 3%). Conclusion: DA-VAMT showed better target dose coverage and achieved better or equal performance in sparing OARs among other techniques. SA-VMAT offered least Treatment Time than other techniques but achieved poor target coverage. DA-VMAT offered

  8. Is uniform target dose possible in IMRT plans in the head and neck?

    International Nuclear Information System (INIS)

    Vineberg, K.A.; Eisbruch, A.; Coselmon, M.M.; McShan, D.L.; Kessler, M.L.; Fraass, B.A.

    2002-01-01

    Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., ±5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition dose calculation and flexible cost functions derived from combinations of clinically relevant factors (costlets) that can include dose, dose-volume, and biologic model-based costlets. The current study compared optimized IMRT plans designed to treat the various planning target volumes to doses of 66, 60, and 54 Gy with varying target dose homogeneity while using a flexible optimization cost function to minimize the dose to the parotids, spinal cord, oral cavity, brainstem, submandibular nodes, and other structures. Results: In all cases, target dose uniformity was achieved through steeply varying dose-based costs. Differences in clinical plan evaluation metrics were evaluated for individual cases (eight different target homogeneity costlets), and for the entire cohort of plans. Highly conformal plans were achieved, with significant sparing of both the contralateral and ipsilateral parotid glands. As the homogeneity of the target dose distributions was allowed to decrease, increased sparing of the parotids (and other normal tissues) may be achieved. However, it

  9. Intensity-modulated radiotherapy for cancers in childhood

    International Nuclear Information System (INIS)

    Leseur, J.; Le Prise, E.; Leseur, J.; Carrie, C.; Beneyton, V.; Bernier, V.; Beneyton, V.; Mahee, M.A.; Supiot, S.

    2009-01-01

    Approximately 40-50% of children with cancer will be irradiated during their treatment. Intensity-modulated radiotherapy (I.M.R.T.) by linear accelerator or helical tomo-therapy improves dose distribution in target volumes and normal tissue sparing. This technology could be particularly useful for pediatric patients to achieve an optimal dose distribution in complex volumes close to critical structures. The use of I.M.R.T. can increase the volume of tissue receiving low-dose radiation, and consequently carcinogenicity in childhood population with a good overall survival and long period of life expectancy. This review will present the current and potential I.M.R.T. indications for cancers in childhood, and discuss the benefits and problems of this technology aiming to define recommendations in the use of I.M.R.T. and specific doses constraints in Pediatrics. (authors)

  10. Dosimetric study of volumetric arc modulation with RapidArc and intensity-modulated radiotherapy in patients with cervical cancer and comparison with 3-dimensional conformal technique for definitive radiotherapy in patients with cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Guy, Jean-Baptiste [Department of Radiation Oncology, Institut de Cancérologie de la Loire Lucien Neuwirth, Saint-Priest en Jarez (France); Falk, Alexander T. [Department of Radiation Oncology, Centre Antoine Lacassagne, Nice (France); Auberdiac, Pierre [Department of Radiation Oncology, Clinique Claude Bernard, Albi (France); Cartier, Lysian; Vallard, Alexis [Department of Radiation Oncology, Institut de Cancérologie de la Loire Lucien Neuwirth, Saint-Priest en Jarez (France); Ollier, Edouard [Department of Pharmacology-Toxicology, Centre Hospitalier Universitaire de Saint-Etienne, Saint-Priest en Jarez (France); Trone, Jane-Chloé; Khodri, Moustapha [Department of Radiation Oncology, Institut de Cancérologie de la Loire Lucien Neuwirth, Saint-Priest en Jarez (France); Chargari, Cyrus [Department of Radiation Oncology, Hôpital d’instruction de Armées du Val-de-Grâce, Paris (France); Magné, Nicolas, E-mail: nicolas.magne@icloire.fr [Department of Radiation Oncology, Institut de Cancérologie de la Loire Lucien Neuwirth, Saint-Priest en Jarez (France)

    2016-04-01

    Introduction: For patients with cervical cancer, intensity-modulated radiation therapy (IMRT) improves target coverage and allows dose escalation while reducing the radiation dose to organs at risk (OARs). In this study, we compared dosimetric parameters among 3-dimensional conformal radiotherapy (3D-CRT), “step-and-shoot” IMRT, and volumetric intensity-modulated arc radiotherapy (VMAT) in a series of patients with cervical cancer receiving definitive radiotherapy. Computed tomography (CT) scans of 10 patients with histologically proven cervical cancer treated with definitive radiation therapy (RT) from December 2008 to March 2010 at our department were selected for this study. The gross tumor volume (GTV) and clinical target volume (CTV) were delineated following the guidelines of the Gyn IMRT consortium that included cervix, uterus, parametrial tissues, and the pelvic nodes including presacral. The median age was 57 years (range: 30 to 85 years). All 10 patients had squamous cell carcinoma with Federation of Gynecology and Obstetrics (FIGO) stage IB-IIIB. All patients were treated by VMAT. OAR doses were significantly reduced for plans with intensity-modulated technique compared with 3D-CRT except for the dose to the vagina. Between the 2 intensity-modulated techniques, significant difference was observed for the mean dose to the small intestine, to the benefit of VMAT (p < 0.001). There was no improvement in terms of OARs sparing for VMAT although there was a tendency for a slightly decreased average dose to the rectum: − 0.65 Gy but not significant (p = 0.07). The intensity modulation techniques have many advantages in terms of quality indexes, and particularly OAR sparing, compared with 3D-CRT. Following the ongoing technologic developments in modern radiotherapy, it is essential to evaluate the intensity-modulated techniques on prospective studies of a larger scale.

  11. Intensity modulated radiation therapy for head and neck cancer: The standard; Radiotherapie avec modulation d'intensite pour les cancers de la tete et du cou: le standard

    Energy Technology Data Exchange (ETDEWEB)

    Maingon, P.; Crehange, G.; Chamois, J.; Khoury, C.; Truc, G. [Departement de radiotherapie, centre Georges-Francois-Leclerc, 1, rue du Pr-Marion, 21079 Dijon cedex (France)

    2011-10-15

    Combined radical radiation therapy for head and neck carcinoma should be planned with intensity modulated beams to provide a rapid answer to patients' requirements in terms of quality of treatment. The most frequent late toxicity of radiation therapy is xerostomia, which may be prevented by using this technique able to significantly spare salivary glands irradiation. Selection of indications is a very important step. The objective of sparing salivary functions, strongly associated with optimization criteria of quality of life should be considered as a main objective in irradiation of head and neck tumours. The various possibilities offered by this technique allowing to boost a target volume included in prophylactically irradiated regions could offer the possibility to escalate the dose in selected patients. The feasibility of this process is currently validated in prospective studies. Finally, routine implementation of intensity modulated radiation therapy should be performed with strong and robust quality assurance procedures, ensuring that the expected benefit could be increased with the current developments by using rotational techniques. (authors)

  12. Comparative study of four advanced 3d-conformal radiation therapy treatment planning techniques for head and neck cancer

    International Nuclear Information System (INIS)

    Herrassi, Mohamed Yassine; Bentayeb, Farida; Malisan, Maria Rosa

    2013-01-01

    For the head-and-neck cancer bilateral irradiation, intensity-modulated radiation therapy (IMRT) is the most reported technique as it enables both target dose coverage and organ-at-risk (OAR) sparing. However, during the last 20 years, three-dimensional conformal radiotherapy (3DCRT) techniques have been introduced, which are tailored to improve the classic shrinking field technique, as regards both planning target volume (PTV) dose conformality and sparing of OARs, such as parotid glands and spinal cord. In this study, we tested experimentally in a sample of 13 patients, four of these advanced 3DCRT techniques, all using photon beams only and a unique isocentre, namely Bellinzona, Forward-Planned Multisegments (FPMS), ConPas, and field-in-field (FIF) techniques. Statistical analysis of the main dosimetric parameters of PTV and OARs DVHs as well as of homogeneity and conformity indexes was carried out in order to compare the performance of each technique. The results show that the PTV dose coverage is adequate for all the techniques, with the FPMS techniques providing the highest value for D95%; on the other hand, the best sparing of parotid glands is achieved using the FIF and ConPas techniques, with a mean dose of 26 Gy to parotid glands for a PTV prescription dose of 54 Gy. After taking into account both PTV coverage and parotid sparing, the best global performance was achieved by the FIF technique with results comparable to that of IMRT plans. This technique can be proposed as a valid alternative when IMRT equipment is not available or patient is not suitable for IMRT treatment. (author)

  13. Dosimetric aspects of breast radiotherapy with three-dimensional and intensity-modulated radiotherapy helical tomotherapy planning modules

    International Nuclear Information System (INIS)

    Yadav, Poonam; Yan, Yue; Ignatowski, Tasha; Olson, Anna

    2017-01-01

    In this work, we investigated the dosimetric differences between the intensity-modulated radiotherapy (IMRT) plans and the three-dimensional (3D) helical plans based on the TomoTherapy system. A total of 15 patients with supine setup were randomly selected from the data base. For patients with lumpectomy planning target volume (PTV), regional lymph nodes were also included as part of the target. For dose sparing, the significant differences between the helical IMRT and helical 3D were only found in the heart and contralateral breast. For the dose to the heart, helical IMRT reduced the maximum point dose by 6.98 Gy compared to the helical 3D plan (p = 0.01). For contralateral breast, the helical IMRT plans significantly reduced the maximum point dose by 5.6 Gy compared to the helical 3D plan. However, compared to the helical 3D plan, the helical IMRT plan increased the volume for lower dose (13.08% increase in V 5 Gy , p = 0.01). In general, there are no significant differences in dose sparing between helical IMRT and helical 3D plans.

  14. VACCINATION OF CHILDREN AGAINST MEASLES, PAROTIDITIS AND VITAMINOTHERAPY

    Directory of Open Access Journals (Sweden)

    S.M. Kharit

    2007-01-01

    Full Text Available The researchers observed 45 children inoculated with the Russian divalent vaccine (measles–parotiditis. 25 children received mineral and vitamin complex «jungle» for a month since the date of vaccination. The application of «jungle» medication was efficient and conduced to prophylaxis of the complication of the vaccination, prevention of the inter current diseases among the vaccinated, as well as positively affected the intensity of the special antibody formation because of activation of cellular and antiviral mechanisms.Key words: vaccination, measles, parotiditis, prevention, mineral and vitamin complex, children.

  15. Patterns of Disease Recurrence Following Treatment of Oropharyngeal Cancer With Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Garden, Adam S., E-mail: agarden@mdanderson.org [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Dong, Lei [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Morrison, William H. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Stugis, Erich M. [Department of Head and Neck Surgery, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Department of Epidemiology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Glisson, Bonnie S. [Department of Thoracic/Head and Neck Medicine, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Frank, Steven J.; Beadle, Beth M.; Gunn, Gary B. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Schwartz, David L. [Department of Radiation Medicine, Long Island Jewish Medical Center, New Hyde Park, NY (United States); Kies, Merill S. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Department of Thoracic/Head and Neck Medicine, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Weber, Randal S. [Department of Head and Neck Surgery, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Ang, K. Kian; Rosenthal, David I. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2013-03-15

    Purpose: To report mature results of a large cohort of patients diagnosed with squamous cell carcinoma of the oropharynx who were treated with intensity modulated radiation therapy (IMRT). Methods and Materials: The database of patients irradiated at The University of Texas, M.D. Anderson Cancer Center was searched for patients diagnosed with oropharyngeal cancer and treated with IMRT between 2000 and 2007. A retrospective review of outcome data was performed. Results: The cohort consisted of 776 patients. One hundred fifty-nine patients (21%) were current smokers, 279 (36%) former smokers, and 337 (43%) never smokers. T and N categories and American Joint Committee on Cancer group stages were distributed as follows: T1/x, 288 (37%); T2, 288 (37%); T3, 113 (15%); T4, 87 (11%); N0, 88(12%); N1/x, 140 (18%); N2a, 101 (13%); N2b, 269 (35%); N2c, 122 (16%); and N3, 56 (7%); stage I, 18(2%); stage II, 40(5%); stage III, 150(19%); and stage IV, 568(74%). Seventy-one patients (10%) presented with nodes in level IV. Median follow-up was 54 months. The 5-year overall survival, locoregional control, and overall recurrence-free survival rates were 84%, 90%, and 82%, respectively. Primary site recurrence developed in 7% of patients, and neck recurrence with primary site control in 3%. We could only identify 12 patients (2%) who had locoregional recurrence outside the high-dose target volumes. Poorer survival rates were observed in current smokers, patients with larger primary (T) tumors and lower neck disease. Conclusions: Patients with oropharyngeal cancer treated with IMRT have excellent disease control. Locoregional recurrence was uncommon, and most often occurred in the high dose volumes. Parotid sparing was accomplished in nearly all patients without compromising tumor coverage.

  16. Improved Dosimetric and Clinical Outcomes With Intensity-Modulated Radiotherapy for Head-and-Neck Cancer of Unknown Primary Origin

    International Nuclear Information System (INIS)

    Chen, Allen M.; Li Baoqing; Farwell, D. Gregory; Marsano, Joseph; Vijayakumar, Srinivasan; Purdy, James A.

    2011-01-01

    Purpose: To compare differences in dosimetric, clinical, and quality-of-life endpoints among a cohort of patients treated by intensity-modulated radiotherapy (IMRT) and conventional radiotherapy (CRT) for head-and-neck cancer of unknown primary origin. Methods and Materials: The medical records of 51 patients treated by radiation therapy for squamous cell carcinoma of the head and neck presenting as cervical lymph node metastasis of occult primary origin were reviewed. Twenty-four patients (47%) were treated using CRT, and 27 (53%) were treated using IMRT. The proportions of patients receiving concurrent chemotherapy were 54% and 63%, respectively. Results: The 2-year estimates of overall survival, local-regional control, and disease-specific survival for the entire patient population were 86%, 89%, and84%, respectively. There were no significant differences in any of these endpoints with respect to radiation therapy technique (p > 0.05 for all). Dosimetric analysis revealed that the use of IMRT resulted in significant improvements with respect to mean dose and V30 to the contralateral (spared) parotid gland. In addition, mean doses to the ipsilateral inner and middle ear structures were significantly reduced with IMRT (p < 0.05 for all). The incidence of severe xerostomia in the late setting was 58% and 11% among patients treated by CRT and IMRT, respectively (p < 0.001). The percentages of patients who were G-tube dependent at 6 months after treatment were 42% and 11%, respectively (p < 0.001). Conclusions: IMRT results in significant improvements in the therapeutic ratio among patients treated by radiation therapy for head-and-neck cancer of unknown primary origin.

  17. Preliminary comp arison of helical tomotherapy and mixed beams of unmodulated electrons and intensity modulated radiation therapy for treating superficial cancers of the parotid gland and nasal cavity

    International Nuclear Information System (INIS)

    Blasi, Olivier; Fontenot, Jonas D; Fields, Robert S; Gibbons, John P; Hogstrom, Kenneth R

    2011-01-01

    To investigate combining unmodulated electron beams with intensity-modulated radiation therapy to improve dose distributions for superficial head and neck cancers, and to compare mixed beam plans with helical tomotherapy. Mixed beam and helical tomotherapy dose plans were developed for two patients with parotid gland tumors and two patients with nasal cavity tumors. Mixed beam plans consisted of various weightings of a enface electron beam and IMRT, which was optimized after calculation of the electron dose to compensate for heterogeneity in the electron dose distribution within the target volume. Helical tomotherapy plans showed dose conformity and homogeneity in the target volume that was equal to or better than the mixed beam plans. Electron-only plans tended to show the lowest doses to normal tissues, but with markedly worse dose conformity and homogeneity than in the other plans. However, adding a 20% IMRT dose fraction (i.e., IMRT:electron weighting = 1:4) to the electron plan restored target conformity and homogeneity to values comparable to helical tomotherapy plans, while maintaining lower normal tissue dose. Mixed beam treatments offer some dosimetric advantages over IMRT or helical tomotherapy for target depths that do not exceed the useful range of the electron beam. Adding a small IMRT component (e.g., IMRT:electron weighting = 1:4) to electron beam plans markedly improved target dose homogeneity and conformity for the cases examined in this study

  18. Impact of anatomical changes on dose distribution of intensity-modulated radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Huang Shaomin; Deng Xiaowu; Zhao Chong; Han Fei; Gao Xingwang; Lu Taixiang; Wang Shi

    2010-01-01

    Objective: To observe the physique and anatomy changes in patients with nasopharyngeal carcinoma (NPC) during intensity-modulated radiotherapy (IMRT), using repeated CT images and deformable registration technique, and analyze their impact on delivery dose distribution. Methods: Ten NPC patients were randomly selected from those who had received IMRT treatment.Gross tumor volume of nasopharynx (GTV nx ), GTV of metastastatic lymph node (GTV nd ), clinical target volume (CTV) and normal tissue or organ (OAR) were re-contoured on the in-course repeated CT images using a kind of deformable registration and auto-segmentation software according to the original planning contouring. Changes in volume of treatment targets and organs at risk were evaluated and the trends were then analyzed. Dose distributions were recalculated with repeated CT images and compared to the original plans. Results: The volume of GTV nx were decreased by 6.44%, 10.23% and 9.72%(F=1.34, P=0.278) in the 2-, 4- and 6-week after IMRT comparing with before IMRT, with 6.59%, 30.98 % and 35.13 % (F = 9.22, P =0.000) in GTV nd , 0.73%, 1.86% and 1.41% (F=0.33, P=0.722) in CTV 1 , -1.78%, -6.47% and -9.34% (F =16.89, P =0.000) in CTV 2 , 13.96%, 32.97% and 37.77%(F=17.17, P=0.000) in the left parotid, and 3.56% , 29.57% and 35.63% (F = 13.49, P = 0.000) in the right parotid. The mean dose change rate of GTV nx were -0.39%, 0.08% and 0.32% (F =0.15, P =0.860) in the 2-, 4- and 6-week after IMRT comparing with planning faction dose, with 0.53%, 1.19% and 0.69% (F=0.81, P=0.455) in GTV nd , 1.95%, 2.70% and 3.78% (F=0.61, P=0.552) in the spinal cord, 0.32%, 0.81% and 0.62% (F=0.03, P=0.975) in the brain stem, 4.50%, 4.66% and 7.20% (F=0.33, P=0.725) in the left parotid, 2.20%, 7.17% and 7.12% (F= 1.24, P=0.306) in the right parotid. Conclusions: The GTV nd , CTV 2 and parotids shrinks obviously along with the treatment times for NPC patients during IMRT. Although changes in fraction dose of GTV, CTV, spinal

  19. Comparison of long-term survival and toxicity of simultaneous integrated boost vs conventional fractionation with intensity-modulated radiotherapy for the treatment of nasopharyngeal carcinoma

    Directory of Open Access Journals (Sweden)

    Tao HM

    2016-03-01

    Full Text Available Hengmin Tao,1,2 Yumei Wei,1 Wei Huang,1 Xiujuan Gai,1,2 Baosheng Li11Department of 6th Radiation Oncology, Shandong Cancer Hospital and Institute, 2School of Medicine and Life Sciences, Jinan University-Shandong Academy of Medical Sciences, Jinan, People’s Republic of ChinaAim: In recent years, the intensity-modulated radiotherapy with simultaneous integrated boost (IMRT-SIB and intensity-modulated radiotherapy with conventional fractionation (IMRT-CF have been involved in the treatment of nasopharyngeal carcinoma (NPC. However, the potential clinical effects and toxicities are still controversial.Methods: Here, 107 patients with biopsy-proven locally advanced NPC between March 2004 and January 2011 were enrolled in the retrospective study. Among them, 54 patients received IMRT-SIB, and 53 patients received IMRT-CF. Subsequently, overall survival (OS, 5-year progression-free survival (PFS, 5-year locoregional recurrence-free survival (LRFS, and relevant toxicities were analyzed.Results: In the present study, all patients completed the treatment, and the overall median follow-up time was 80 months (range: 8–126 months. The 5-year OS analysis revealed no significant difference between the IMRT-SIB and IMRT-CF groups (80.9% vs 80.5%, P=0.568. In addition, there were also no significant between-group differences in 5-year PFS (73.3% vs 74.4%, P=0.773 and 5-year LRFS (88.1% vs 90.8%, P=0.903. Notably, the dose to critical organs (spinal cord, brainstem, and parotid gland in patients treated by IMRT-CF was significantly lower than that in patients treated by IMRT-SIB (all P<0.05.Conclusion: Both IMRT-SIB and IMRT-CF techniques are effective in treating locally advanced NPC, with similar OS, PFS, and LRFS. However, IMRT-CF has more advantages than IMRT-SIB in protecting spinal cord, brainstem, and parotid gland from acute and late toxicities, such as xerostomia. Further prospective study is warranted to confirm our findings.Keywords: intensity-modulated

  20. Importance of the initial volume of parotid glands in xerostomia for patients with head and neck cancers treated with IMRT

    International Nuclear Information System (INIS)

    Nishimura, Yasumasa; Nakamatsu, Kiyoshi; Shibata, Toru; Kanamori, Shuichi; Koike, Ryuta; Okumura, Masahiko; Suzuki, Minoru

    2005-01-01

    Our aim was to evaluate predictors of xerostomia in patients with head and neck cancers treated with intensity-modulated radiation therapy (IMRT). Thirty-three patients with pharyngeal cancer were evaluated for xerostomia after having been treated with IMRT. All patients were treated with whole-neck irradiation of 46-50 Gy by IMRT, followed by boost IMRT to the high-risk clinical target volume to a total dose of 56-70 Gy in 28-35 fractions (median, 68 Gy). For boost IMRT, a second computed tomography (CT-2) scan was done in the third to fourth week of IMRT. Xerostomia was scored 3-4 months after the start of IMRT. The mean doses to the contralateral and ipsilateral parotid glands were 24.0±6.2 and 30.3±6.6 Gy, respectively. Among the 33 patients, xerostomia of grades 0, 1, 2 and 3 was noted in one, 18, 12 and two patients, respectively. Although the mean dose to the parotid glands was not correlated with the grade of xerostomia, the initial volume of the parotid glands was correlated with the grade of xerostomia (P=0.04). Of 17 patients with small parotid glands (≤38.8 ml) on initial CT (CT-1), 11 (65%) showed grade 2 or grade 3 xerostomia, whereas only three (19%) of 16 patients with larger parotid glands showed grade 2 xerostomia (P<0.05). The mean volume of the parotid glands on CT-1 was 43.1±15.2 ml, but decreased significantly to 32.0±11.4 ml (74%) on CT-2 (P<0.0001). Initial volumes of the parotid glands are significantly correlated with the grade of xerostomia in patients treated with IMRT. The volume of the parotid glands decreased significantly during the course of IMRT. (author)

  1. Local Anatomic Changes in Parotid and Submandibular Glands During Radiotherapy for Oropharynx Cancer and Correlation With Dose, Studied in Detail With Nonrigid Registration

    International Nuclear Information System (INIS)

    Vasquez Osorio, Eliana M.; Hoogeman, Mischa S.; Al-Mamgani, Abrahim; Teguh, David N.; Levendag, Peter C.; Heijmen, Ben J.M.

    2008-01-01

    Purpose: To quantify the anatomic changes caused by external beam radiotherapy in head-and-neck cancer patients in full three dimensions and to relate the local anatomic changes to the planned mean dose. Methods and Materials: A nonrigid registration method was adapted for RT image registration. The method was applied in 10 head-and-neck cancer patients, who each underwent a planning and a repeat computed tomography scan. Contoured structures (parotid, submandibular glands, and tumor) were registered in a nonrigid manner. The accuracy of the transformation was determined. The transformation results were used to summarize the anatomic changes on a local scale for the irradiated and spared glands. The volume reduction of the glands was related to the planned mean dose. Results: Transformation was accurate with a mean error of 0.6 ± 0.5 mm. The volume of all glands and the primary tumor decreased. The lateral regions of the irradiated parotid glands moved inward (average, 3 mm), and the medial regions tended to remain in the same position. The irradiated submandibular glands shrank and moved upward. The spared glands showed only a small deformation (∼1 mm in most regions). Overall, the primary tumors shrank. The volume loss of the parotid glands correlated significantly with the planned mean dose (p <0.001). Conclusion: General shrinkage and deformation of irradiated glands was seen. The spared glands showed few changes. These changes were assessed by a nonrigid registration method, which effectively described the local changes occurring in the head-and-neck region after external beam radiotherapy

  2. Treatment of eccrine porocarcinoma with metastasis to the parotid gland using intensity-modulated radiation therapy: a case report

    Directory of Open Access Journals (Sweden)

    Lentsch Eric J

    2010-05-01

    Full Text Available Abstract Introduction Cutaneous eccrine porocarcinomas are uncommon malignant tumors of the sweat gland. Case Presentation A 76-year-old Caucasian man presented to our hospital with a left temporal mass. We describe a case of eccrine porocarcinoma with metastasis to the parotid gland with special emphasis on the role of surgical resection and adjuvant radiation therapy. Conclusion Besides surgical resection, little is known about the role of adjuvant therapy in managing eccrine porocarcinomas. Radiation therapy should be considered within a multidisciplinary approach in patients with primary or recurrent eccrine porocarcinomas.

  3. High-resolution magnetic resonance of the extracranial facial nerve and parotid duct: demonstration of the branches of the intraparotid facial nerve and its relation to parotid tumours by MRI with a surface coil

    International Nuclear Information System (INIS)

    Takahashi, N.; Okamoto, K.; Ohkubo, M.; Kawana, M.

    2005-01-01

    AIM: To investigate the usefulness of high-resolution MR imaging in the evaluation of the extracranial facial nerve, compared with surgical findings. MATERIALS AND METHODS: Thirteen patients with benign parotid tumours were studied on a 1.5-T MR system with a 3 in circular surface coil. High-resolution T1-weighted spin-echo, T2-weighted fast spin-echo, and three-dimensional gradient-recalled acquisition in the steady state (GRASS) images were obtained in the axial planes. Oblique reformatted images were generated. Tumours, parotid ducts and facial nerves were identified on these images. The relationship of the tumours to the facial nerves was confirmed at surgery. RESULTS: Facial nerves appeared as linear structures of low intensity on all pulse sequences. The main trunks and cervicofacial and temporofacial divisions of the facial nerves were identified in 100%, 84.1% and 53.8% of GRASS images, respectively. Parotid ducts appeared as structures of low intensity on T1-weighted (66.6%) and GRASS images (81.8%), and as structures of very high intensity on T2-weighted images (91.7%). The relationships of the tumours to the facial nerves were correctly diagnosed in 11 (91.7%) of 12 cases. CONCLUSION: High-resolution MR imaging depicts the extracranial facial nerve and the parotid duct, and is useful for preoperative evaluation of parotid gland tumours

  4. High-resolution magnetic resonance of the extracranial facial nerve and parotid duct: demonstration of the branches of the intraparotid facial nerve and its relation to parotid tumours by MRI with a surface coil

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, N. [Department of Radiology, Niigata University Faculty of Medicine, Niigata (Japan) and Department of Radiology, Niigata City General Hospital, Niigata (Japan)]. E-mail: nandtr@hosp.niigata.niigata.jp; Okamoto, K. [Department of Radiology, Niigata University Faculty of Medicine, Niigata (Japan); Ohkubo, M. [Department of Radiotechnology, Niigata University Faculty of Medicine, Niigata (Japan); Kawana, M. [Department of Otorhinolaryngology, Niigata University Faculty of Medicine, Niigata (Japan)

    2005-03-01

    AIM: To investigate the usefulness of high-resolution MR imaging in the evaluation of the extracranial facial nerve, compared with surgical findings. MATERIALS AND METHODS: Thirteen patients with benign parotid tumours were studied on a 1.5-T MR system with a 3 in circular surface coil. High-resolution T1-weighted spin-echo, T2-weighted fast spin-echo, and three-dimensional gradient-recalled acquisition in the steady state (GRASS) images were obtained in the axial planes. Oblique reformatted images were generated. Tumours, parotid ducts and facial nerves were identified on these images. The relationship of the tumours to the facial nerves was confirmed at surgery. RESULTS: Facial nerves appeared as linear structures of low intensity on all pulse sequences. The main trunks and cervicofacial and temporofacial divisions of the facial nerves were identified in 100%, 84.1% and 53.8% of GRASS images, respectively. Parotid ducts appeared as structures of low intensity on T1-weighted (66.6%) and GRASS images (81.8%), and as structures of very high intensity on T2-weighted images (91.7%). The relationships of the tumours to the facial nerves were correctly diagnosed in 11 (91.7%) of 12 cases. CONCLUSION: High-resolution MR imaging depicts the extracranial facial nerve and the parotid duct, and is useful for preoperative evaluation of parotid gland tumours.

  5. Dosimetric and Clinical Outcomes With Intensity Modulated Radiation Therapy After Chemotherapy for Patients With Early-Stage Diffuse Large B-cell Lymphoma of Waldeyer Ring

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yong-Gang; Qi, Shu-Nan; Wang, Shu-Lian; Liu, Yue-Ping; Wang, Wei-Hu; Jin, Jing; Song, Yong-Wen; Ren, Hua; Fang, Hui [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); He, Xiao-Hui; Dong, Mei [Department of Medical Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Chen, Bo; Lu, Ning-Ning; Li, Ning; Tang, Yuan; Tang, Yu; Dai, Jian-Rong [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Li, Ye-Xiong, E-mail: yexiong12@163.com [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China)

    2016-10-01

    Purpose: To assess the dosimetric benefit, prognosis, and toxicity of intensity modulated radiation therapy (IMRT) for early-stage, diffuse large B-cell lymphoma of Waldeyer ring (WR-DLBCL). Methods and Materials: Sixty-one patients with early-stage WR-DLBCL who received chemotherapy followed by IMRT were retrospectively reviewed. Dosimetric parameters for the target volume and critical normal structures were evaluated, and survival was calculated. Linear regression analysis was used to assess the effect of the mean dose (D{sub mean}) to the parotid glands on xerostomia. Results: The median conformity index and homogeneity index of the planning target volume (PTV) were 0.83 and 0.90, respectively, demonstrating very good coverage of the target volume. The mean dose to the parotid glands was 24.9 Gy. The 5-year overall survival (OS), progression-free survival (PFS), and locoregional control (LRC) were 94.7%, 93.1%, and 98.3%, respectively. Early and late toxicities were mild, and no patient experienced late grade ≥3 toxicities. The D{sub mean} to the parotid glands had a linear correlation with late grade ≥2 xerostomia. Conclusions: IMRT after chemotherapy can provide excellent dose conformity and achieve favorable survival and LRC with mild toxicities in patients with early-stage WR-DLBCL. Dose constraints for the parotid glands should be limited to <24 Gy for early-stage WR-DLBCL.

  6. Dosimetric effect of beam arrangement for intensity-modulated radiation therapy in the treatment of upper thoracic esophageal carcinoma

    International Nuclear Information System (INIS)

    Fu, Yuchuan; Deng, Min; Zhou, Xiaojuan; Lin, Qiang; Du, Bin; Tian, Xue; Xu, Yong; Wang, Jin; Lu, You; Gong, Youling

    2017-01-01

    To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plans were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V 5 , V 13 , V 20 , mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V 30 for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy with intensity-modulated

  7. Dosimetric effect of beam arrangement for intensity-modulated radiation therapy in the treatment of upper thoracic esophageal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Yuchuan [Division of Radiation Physics, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu (China); Deng, Min; Zhou, Xiaojuan [Department of Thoracic Oncology, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu (China); Lin, Qiang; Du, Bin [Division of Radiation Physics, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu (China); Tian, Xue; Xu, Yong; Wang, Jin; Lu, You [Department of Thoracic Oncology, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu (China); Gong, Youling, E-mail: gongyouling@hotmail.com [Department of Thoracic Oncology, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu (China)

    2017-04-01

    To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plans were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V{sub 5}, V{sub 13}, V{sub 20}, mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V{sub 30} for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy

  8. Preliminary results of a phase I/II study of simultaneous modulated accelerated radiotherapy for nondisseminated nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Lee, Sang-wook; Back, Geum Mun; Yi, Byong Yong; Choi, Eun Kyung; Ahn, Seung Do; Shin, Seong Soo; Kim, Jung-hun; Kim, Sang Yoon; Lee, Bong-Jae; Nam, Soon Yuhl; Choi, Seung-Ho; Kim, Seung-Bae; Park, Jin-hong; Lee, Kang Kyoo; Park, Sung Ho; Kim, Jong Hoon

    2006-01-01

    Purpose: To present preliminary results of intensity-modulated radiotherapy (IMRT) with the simultaneous modulated accelerated radiotherapy (SMART) boost technique in patients with nasopharyngeal carcinoma (NPC). Methods and Materials: Twenty patients who underwent IMRT for nondisseminated NPC at the Asan Medical Center between September 2001 and December 2003 were prospectively evaluated. Intensity-modulated radiotherapy was delivered with the 'step and shoot' SMART technique at prescribed doses of 72 Gy (2.4 Gy/day) to the gross tumor volume, 60 Gy (2 Gy/day) to the clinical target volume and metastatic nodal station, and 46 Gy (2 Gy/day) to the clinically negative neck region. Eighteen patients also received cisplatin once per week. Results: The median follow-up period was 27 months. Nineteen patients completed the treatment without interruption; the remaining patient interrupted treatment for 2 weeks owing to severe pharyngitis and malnutrition. Five patients (25%) had Radiation Therapy Oncology Group Grade 3 mucositis, whereas 9 (45%) had Grade 3 pharyngitis. Seven patients (35%) lost more than 10% of their pretreatment weight, whereas 11 (55%) required intravenous fluids and/or tube feeding. There was no Grade 3 or 4 xerostomia. All patients showed complete response. Two patients had distant metastases and locoregional recurrence, respectively. Conclusion: Intensity-modulated radiotherapy with the SMART boost technique allows parotid sparing, as shown clinically and by dosimetry, and might also be more effective biologically. A larger population of patients and a longer follow-up period are needed to evaluate ultimate tumor control and late toxicity

  9. Role of beam orientation optimization in intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Pugachev, Andrei; Li, Jonathan G.; Boyer, Arthur L.; Hancock, Steven L.; Le, Quynh-Thu; Donaldson, Sarah S.; Lei Xing

    2001-01-01

    Purpose: To investigate the role of beam orientation optimization in intensity-modulated radiation therapy (IMRT) and to examine the potential benefits of noncoplanar intensity-modulated beams. Methods and Materials: A beam orientation optimization algorithm was implemented. For this purpose, system variables were divided into two groups: beam position (gantry and table angles) and beam profile (beamlet weights). Simulated annealing was used for beam orientation optimization and the simultaneous iterative inverse treatment planning algorithm (SIITP) for beam intensity profile optimization. Three clinical cases were studied: a localized prostate cancer, a nasopharyngeal cancer, and a paraspinal tumor. Nine fields were used for all treatments. For each case, 3 types of treatment plan optimization were performed: (1) beam intensity profiles were optimized for 9 equiangular spaced coplanar beams; (2) orientations and intensity profiles were optimized for 9 coplanar beams; (3) orientations and intensity profiles were optimized for 9 noncoplanar beams. Results: For the localized prostate case, all 3 types of optimization described above resulted in dose distributions of a similar quality. For the nasopharynx case, optimized noncoplanar beams provided a significant gain in the gross tumor volume coverage. For the paraspinal case, orientation optimization using noncoplanar beams resulted in better kidney sparing and improved gross tumor volume coverage. Conclusion: The sensitivity of an IMRT treatment plan with respect to the selection of beam orientations varies from site to site. For some cases, the choice of beam orientations is important even when the number of beams is as large as 9. Noncoplanar beams provide an additional degree of freedom for IMRT treatment optimization and may allow for notable improvement in the quality of some complicated plans

  10. Cervix carcinomas: place of intensity-modulated radiotherapy; Les cancers du col uterin: place de la radiotherapie avec modulation d'intensite

    Energy Technology Data Exchange (ETDEWEB)

    Barillot, I. [Centre Regional Universitaire de Cancerologie H.S.-Kaplan, Hopital Bretonneau, CHU de Tours, 37 - Tours (France); Universite Francois-Rabelais, 37 - Tours (France)

    2009-10-15

    While indications of modulated intensity radiation therapy (I.M.R.T.) are perfectly defined in head and neck and prostate cancer patients, this technique remains under evaluation for gynecologic tumours. The implementation of conformal three dimensional radiotherapy in the late 1990 has been the first important step for optimisation of treatment of cervix carcinomas, as it permitted a better target coverage with a significant reduction of the bladder dose. However, this technique often leads to an irradiation of a larger volume of rectum in locally advanced stages and could only spare a limited amount of intestine. I.R.M.T. is one of the optimisation methods potentially efficient for a better sparing of digestive tract during irradiation of cervix carcinomas. The aim of this literature review is to provide the arguments supporting this hypothesis, and to define the place of this technique for dose escalation. (authors)

  11. Automated IMRT planning in Pinnacle. A study in head-and-neck cancer

    International Nuclear Information System (INIS)

    Kusters, J.M.A.M.; Kollenburg, P.G.M. van; Kunze-Busch, M.C.; Wendling, M.; Dijkema, T.; Kaanders, J.H.A.M.; Bzdusek, K.; Kumar, P.

    2017-01-01

    This study evaluates the performance and planning efficacy of the Auto-Planning (AP) module in the clinical version of Pinnacle 9.10 (Philips Radiation Oncology Systems, Fitchburg, WI, USA). Twenty automated intensity-modulated radiotherapy (IMRT) plans were compared with the original manually planned clinical IMRT plans from patients with oropharyngeal cancer. Auto-Planning with IMRT offers similar coverage of the planning target volume as the original manually planned clinical plans, as well as better sparing of the contralateral parotid gland, contralateral submandibular gland, larynx, mandible, and brainstem. The mean dose of the contralateral parotid gland and contralateral submandibular gland could be reduced by 2.5 Gy and 1.7 Gy on average. The number of monitor units was reduced with an average of 143.9 (18%). Hands-on planning time was reduced from 1.5-3 h to less than 1 h. The Auto-Planning module was able to produce clinically acceptable head and neck IMRT plans with consistent quality. (orig.) [de

  12. Automated IMRT planning in Pinnacle : A study in head-and-neck cancer.

    Science.gov (United States)

    Kusters, J M A M; Bzdusek, K; Kumar, P; van Kollenburg, P G M; Kunze-Busch, M C; Wendling, M; Dijkema, T; Kaanders, J H A M

    2017-12-01

    This study evaluates the performance and planning efficacy of the Auto-Planning (AP) module in the clinical version of Pinnacle 9.10 (Philips Radiation Oncology Systems, Fitchburg, WI, USA). Twenty automated intensity-modulated radiotherapy (IMRT) plans were compared with the original manually planned clinical IMRT plans from patients with oropharyngeal cancer. Auto-Planning with IMRT offers similar coverage of the planning target volume as the original manually planned clinical plans, as well as better sparing of the contralateral parotid gland, contralateral submandibular gland, larynx, mandible, and brainstem. The mean dose of the contralateral parotid gland and contralateral submandibular gland could be reduced by 2.5 Gy and 1.7 Gy on average. The number of monitor units was reduced with an average of 143.9 (18%). Hands-on planning time was reduced from 1.5-3 h to less than 1 h. The Auto-Planning module was able to produce clinically acceptable head and neck IMRT plans with consistent quality.

  13. Hippocampal sparing radiotherapy for pediatric medulloblastoma: impact of treatment margins and treatment technique.

    Science.gov (United States)

    Brodin, N Patrik; Munck af Rosenschöld, Per; Blomstrand, Malin; Kiil-Berthlesen, Anne; Hollensen, Christian; Vogelius, Ivan R; Lannering, Birgitta; Bentzen, Søren M; Björk-Eriksson, Thomas

    2014-04-01

    We investigated how varying the treatment margin and applying hippocampal sparing and proton therapy impact the risk of neurocognitive impairment in pediatric medulloblastoma patients compared with current standard 3D conformal radiotherapy. We included 17 pediatric medulloblastoma patients to represent the variability in tumor location relative to the hippocampal region. Treatment plans were generated using 3D conformal radiotherapy, hippocampal sparing intensity-modulated radiotherapy, and spot-scanned proton therapy, using 3 different treatment margins for the conformal tumor boost. Neurocognitive impairment risk was estimated based on dose-response models from pediatric CNS malignancy survivors and compared among different margins and treatment techniques. Mean hippocampal dose and corresponding risk of cognitive impairment were decreased with decreasing treatment margins (P < .05). The largest risk reduction, however, was seen when applying hippocampal sparing proton therapy-the estimated risk of impaired task efficiency (95% confidence interval) was 92% (66%-98%), 81% (51%-95%), and 50% (30%-70%) for 3D conformal radiotherapy, intensity-modulated radiotherapy, and proton therapy, respectively, for the smallest boost margin and 98% (78%-100%), 90% (60%-98%), and 70% (39%-90%) if boosting the whole posterior fossa. Also, the distance between the closest point of the planning target volume and the center of the hippocampus can be used to predict mean hippocampal dose for a given treatment technique. We estimate a considerable clinical benefit of hippocampal sparing radiotherapy. In choosing treatment margins, the tradeoff between margin size and risk of neurocognitive impairment quantified here should be considered.

  14. Influence of jaw tracking in intensity-modulated and volumetric-modulated arc radiotherapy for head and neck cancers: a dosimetric study

    Energy Technology Data Exchange (ETDEWEB)

    Mani, Karthick Raj [Research and Development Centre, Bharathiar University, Tamilnadu (India); Upadhayay, Sagar [Radiation Oncology, Kathmandu Cancer Center, Bhaktapur (Nepal); Das, K. J. Maria [Dept. of Radiotherapy, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Uttar Pradesh (India)

    2017-03-15

    To Study the dosimetric advantage of the Jaw tracking technique in intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for Head and Neck Cancers. We retrospectively selected 10 previously treated head and neck cancer patients stage (T1/T2, N1, M0) in this study. All the patients were planned for IMRT and VMAT with simultaneous integrated boost technique. IMRT and VMAT plans were performed with jaw tracking (JT) and with static jaw (SJ) technique by keeping the same constraints and priorities for a particular patient. Target conformity, dose to the critical structures and low dose volumes were recorded and analyzed for IMRT and VMAT plans with and without JT for all the patients. The conformity index average of all patients followed by standard deviation (x¯x¯ ± σx¯σx¯) of the JT-IMRT, SJ-IMRT, JT-VMAT, and SJ-VMAT were 1.72 ± 0.56, 1.67 ± 0.57, 1.83 ± 0.65, and 1.85 ± 0.64, and homogeneity index were 0.059 ± 0.05, 0.064 ± 0.05, 0.064 ± 0.04, and 0.064 ± 0.05. JT-IMRT shows significant mean reduction in right parotid and left parotid shows of 7.64% (p < 0.001) and 7.45% (p < 0.001) compare to SJ-IMRT. JT-IMRT plans also shows considerable dose reduction to thyroid, inferior constrictors, spinal cord and brainstem compared to the SJ-IMRT plans. Significant dose reductions were observed for critical structure in the JT-IMRT compared to SJ-IMRT technique. In JT-VMAT plans dose reduction to the critical structure were not significant compared to the SJ-IMRT due to relatively lesser monitor units.

  15. Role of the parameters involved in the plan optimization based on the generalized equivalent uniform dose and radiobiological implications

    International Nuclear Information System (INIS)

    Widesott, L; Strigari, L; Pressello, M C; Landoni, V; Benassi, M

    2008-01-01

    We investigated the role and the weight of the parameters involved in the intensity modulated radiation therapy (IMRT) optimization based on the generalized equivalent uniform dose (gEUD) method, for prostate and head-and-neck plans. We systematically varied the parameters (gEUD max and weight) involved in the gEUD-based optimization of rectal wall and parotid glands. We found that the proper value of weight factor, still guaranteeing planning treatment volumes coverage, produced similar organs at risks dose-volume (DV) histograms for different gEUD max with fixed a = 1. Most of all, we formulated a simple relation that links the reference gEUD max and the associated weight factor. As secondary objective, we evaluated plans obtained with the gEUD-based optimization and ones based on DV criteria, using the normal tissue complication probability (NTCP) models. gEUD criteria seemed to improve sparing of rectum and parotid glands with respect to DV-based optimization: the mean dose, the V 40 and V 50 values to the rectal wall were decreased of about 10%, the mean dose to parotids decreased of about 20-30%. But more than the OARs sparing, we underlined the halving of the OARs optimization time with the implementation of the gEUD-based cost function. Using NTCP models we enhanced differences between the two optimization criteria for parotid glands, but no for rectum wall

  16. Dosimetric aspects of breast radiotherapy with three-dimensional and intensity-modulated radiotherapy helical tomotherapy planning modules

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, Poonam [Department of Human Oncology, University of Wisconsin-Madison, Madison, WI (United States); Service of Radiation Therapy, University of Wisconsin Aspirus Cancer Center, Wisconsin Rapids, WI (United States); Yan, Yue, E-mail: yyan5@mdanderson.org [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Ignatowski, Tasha [Service of Radiation Therapy, University of Wisconsin Aspirus Cancer Center, Wisconsin Rapids, WI (United States); Olson, Anna [Department of Human Oncology, University of Wisconsin-Madison, Madison, WI (United States); Service of Radiation Therapy, University of Wisconsin Aspirus Cancer Center, Wisconsin Rapids, WI (United States)

    2017-04-01

    In this work, we investigated the dosimetric differences between the intensity-modulated radiotherapy (IMRT) plans and the three-dimensional (3D) helical plans based on the TomoTherapy system. A total of 15 patients with supine setup were randomly selected from the data base. For patients with lumpectomy planning target volume (PTV), regional lymph nodes were also included as part of the target. For dose sparing, the significant differences between the helical IMRT and helical 3D were only found in the heart and contralateral breast. For the dose to the heart, helical IMRT reduced the maximum point dose by 6.98 Gy compared to the helical 3D plan (p = 0.01). For contralateral breast, the helical IMRT plans significantly reduced the maximum point dose by 5.6 Gy compared to the helical 3D plan. However, compared to the helical 3D plan, the helical IMRT plan increased the volume for lower dose (13.08% increase in V{sub 5} {sub Gy}, p = 0.01). In general, there are no significant differences in dose sparing between helical IMRT and helical 3D plans.

  17. A survey of techniques to reduce and manage external beam radiation-induced xerostomia in British oncology and radiotherapy departments

    International Nuclear Information System (INIS)

    Macknelly, Andrew; Day, Jane

    2009-01-01

    Xerostomia is the most common side effect of external beam radiotherapy to the head and neck [Anand A, Jain J, Negi P, Chaudhoory A, Sinha S, Choudhury P, et-al. Can dose reduction to one parotid gland prevent xerostomia? - A feasibility study for locally advanced head and neck cancer patients treated with intensity-modulated radiotherapy. Clinical Oncology 2006;18(6):497-504.]. A survey was carried out in British oncology departments to determine what treatment regimes, to minimise xerostomia, are used for patients with head-and-neck cancers treated with external beam radiotherapy. A semi-structured questionnaire consisting of both quantitative and qualitative questions was designed that asked departments which of the identified methods they used, why a method might not be currently employed, and whether its use had ever been considered. The study found that there are wide disparities between the techniques employed by oncology departments to avoid and reduce xerostomia in patients with cancers of the head and neck. The National Institute of Clinical Health and Excellence, [National Institute for Clinical Health and Excellence (NICE). Improving outcomes in head and neck cancers: the manual. London: Office of Public Sector Information; 2004.] for example, recommends that patients are given dental care and dietary advice but some departments did not appear to be doing this. Less than half of departments stated that they offer complementary therapies and less than 40% prescribed pilocarpine, a saliva-stimulant. Only two respondents stated that they use amifostine, a radioprotector, during radiotherapy treatment to the head and neck. The results also suggested a move toward using Intensity Modulated Radiotherapy (IMRT) for treating head-and-neck cancers which offers better normal tissue sparing than three-dimensional conformal radiotherapy. [Anand A, Jain J, Negi P, Chaudhoory A, Sinha S, Choudhury P, et al. Can dose reduction to one parotid gland prevent xerostomia

  18. SU-E-T-409: Intensity Modulated Robotic Radiotherapy

    International Nuclear Information System (INIS)

    Wang, B; Jin, L; Li, J; Chen, L; Ma, C; Fan, J; Zhang, C

    2014-01-01

    Purpose: As compared with the IRIS-based models, the MLC-based CyberKnife system allows more efficient treatment delivery due to its improved coverage of large lesions and intensity modulation. The treatment delivery efficiency is mainly determined by the number of selected nodes. This study aimed to demonstrate that relatively small sets of optimally selected nodes could produce high-quality plans. Methods: The full body path of the CyberKnife system consists of 110 nodes, from which we selected various sets for 4 prostate cancer cases using our in-house beamselection software. With the selected nodes we generated IMRT plans using our in-house beamlet-based inverse-planning optimization program. We also produced IMRT plans using the MultiPlan treatment planning system (version 5.0) for the same cases. Furthermore, the nodes selected by MultiPlan were used to produce plans with our own optimization software so that we could compare the quality of the selected sets of nodes. Results: Our beam-selection program selected one node-set for each case, with the number of nodes ranging from 23 to 34. The IMRT plans based on the selected nodes and our in-house optimization program showed adequate target coverage, with favorable critical structure sparing for the cases investigated. Compared with the plans using the nodes selected by MultiPlan, the plans generated with our selected beams provided superior rectum/bladder sparing for 75% of the cases. The plans produced by MultiPlan with various numbers of nodes also suggested that the plan quality was not compromised significantly when the number of nodes was reduced. Conclusion: Our preliminary results showed that with beamletbased planning optimization, one could produce high-quality plans with an optimal set of nodes for MLC-based robotic radiotherapy. Furthermore, our beam-selection strategy could help further improve critical structure sparing

  19. Histopathologic correlation of parotid tumors

    International Nuclear Information System (INIS)

    Ramirez Valverde, Jose Miguel

    2014-01-01

    Malignization percentage of parotid pleomorphic adenoma is defined with fine needle aspiration biopsy (FNAB), prior negative in patients operated by parotid tumor in the Hospital San Juan de Dios between 2008-2012. Patients diagnosed with pleomorphic adenoma by FNAB are described in time, place and person. The histological type of parotid tumors diagnosed are defined. Management offered to patients diagnosed with parotid tumors is understood in the Hospital San Juan de Dios. Complications associated with surgical procedure in patients are specified. A quarter part the of parotid tumors from the series analyzed have been malignant, a similar percentage described in the literature [es

  20. Effects of isoflurane anesthesia and pilocarpine on rat parotid saliva flow

    DEFF Research Database (Denmark)

    Knudsen, Jacob Dronninglund; Nauntofte, Birgitte; Josipovic, M

    2011-01-01

    The purpose of this study was to investigate the effects of isoflurane on unstimulated and pilocarpine-stimulated parotid saliva secretion. Ten male Sprague-Dawley rats weighing 350-400 g were randomized into two groups, and the saliva flow rate and lag phase were measured at two doses of isoflur......The purpose of this study was to investigate the effects of isoflurane on unstimulated and pilocarpine-stimulated parotid saliva secretion. Ten male Sprague-Dawley rats weighing 350-400 g were randomized into two groups, and the saliva flow rate and lag phase were measured at two doses...... of isoflurane in a crossover study design. Increasing the isoflurane concentration from 1% to 2% was associated with a 19% decrease in saliva secretion rate, and the lag to saliva secretion was increased by 155%. To clarify whether the effect of isoflurane (1.5%) on the parotid flow varied with stimulus...... intensity, we measured the parotid flow induced by seven different doses of pilocarpine on sham-irradiated rats and rats irradiated with single doses of 15 Gy. A maximal pilocarpine response was obtained with 1.5 mg/kg in both irradiated and sham-irradiated rats; however, the parotid flow of the irradiated...

  1. Intensity-modulated three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Mohan, Radhe

    1996-01-01

    Optimized intensity-modulated treatments one of the important advances in photon radiotherapy. Intensity modulation provides a greatly increased control over dose distributions. Such control can be maximally exploited to achieve significantly higher levels of conformation to the desired clinical objectives using sophisticated optimization techniques. Safe, rapid and efficient delivery of intensity-modulated treatments has become feasible using a dynamic multi-leaf collimator under computer control. The need for all other field shaping devices such as blocks, wedges and compensators is eliminated. Planning and delivery of intensity-modulated treatments is amenable to automation and development of class solutions for each treatment site and stage which can be implemented not only at major academic centers but on a wide scale. A typical treatment involving as many as 10 fields can be delivered in times shorter than much simpler conventional treatments. The main objective of the course is to give an overview of the current state of the art of planning and delivery methods of intensity-modulated treatments. Specifically, the following topics will be covered using representative optimized plans and treatments: 1. A typical procedure for planning and delivering an intensity-modulated treatment. 2. Quantitative definition of criteria (i.e., the objective function) of optimization of intensity-modulated treatments. Clinical relevance of objectives and the dependence of the quality of optimized intensity-modulated plans upon whether the objectives are stated purely in terms of simple dose or dose-volume criteria or whether they incorporate biological indices. 3. Importance of the lateral transport of radiation in the design of intensity-modulated treatments. Impact on dose homogeneity and the optimum choice of margins. 4. Use of intensity-modulated treatments in escalation of tumor dose for the same or lower normal tissue dose. Fractionation of intensity-modulated treatments

  2. Intensity-modulated three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Mohan, Radhe

    1997-01-01

    Optimized intensity-modulated treatments one of the important advances in photon radiotherapy. Intensity modulation provides a greatly increased control over dose distributions. Such control can be maximally exploited to achieve significantly higher levels of conformation to the desired clinical objectives using sophisticated optimization techniques. Safe, rapid and efficient delivery of intensity-modulated treatments has become feasible using a dynamic multi-leaf collimator under computer control. The need for all other field shaping devices such as blocks, wedges and compensators is eliminated. Planning and delivery of intensity-modulated treatments is amenable to automation and development of class solutions for each treatment site and stage which can be implemented not only at major academic centers but on a wide scale. A typical treatment involving as many as 10 fields can be delivered in times shorter than much simpler conventional treatments. The main objective of the course is to give an overview of the current state of the art of planning and delivery methods of intensity-modulated treatments. Specifically, the following topics will be covered using representative optimized plans and treatments: 1. A typical procedure for planning and delivering an intensity-modulated treatment. 2. Quantitative definition of criteria (i.e., the objective function) of optimization of intensity-modulated treatments. Clinical relevance of objectives and the dependence of the quality of optimized intensity-modulated plans upon whether the objectives are stated purely in terms of simple dose or dose-volume criteria or whether they incorporate biological indices. 3. Importance of the lateral transport of radiation in the design of intensity-modulated treatments. Impact on dose homogeneity and the optimum choice of margins. 4. Use of intensity-modulated treatments in escalation of tumor dose for the same or lower normal tissue dose. Fractionation of intensity-modulated treatments

  3. Comprehensive irradiation of head and neck cancer using conformal multisegmental fields: assessment of target coverage and noninvolved tissue sparing

    International Nuclear Information System (INIS)

    Eisbruch, Avraham; Marsh, Lon H.; Martel, Mary K.; Ship, Jonathan A.; Haken, Randall ten; Pu, Anthony T.; Fraass, Benedick A.; Lichter, Allen S.

    1998-01-01

    Purpose: Conformal treatment using static multisegmental intensity modulation was developed for patients requiring comprehensive irradiation for head and neck cancer. The major aim is sparing major salivary gland function while adequately treating the targets. To assess the adequacy of the conformal plans regarding target coverage and dose homogeneity, they were compared with standard irradiation plans. Methods and Materials: Fifteen patients with stage III/IV head and neck cancer requiring comprehensive, bilateral neck irradiation participated in this study. CT-based treatment plans included five to six nonopposed fields, each having two to four in-field segments. Fields and segments were devised using beam's eye views of the planning target volumes (PTVs), noninvolved organs, and isodose surfaces, to achieve homogeneous dose distribution that encompassed the targets and spared major salivary gland tissue. For comparison, standard three-field radiation plans were devised retrospectively for each patient, with the same CT-derived targets used for the clinical (conformal) plans. Saliva flow rates from each major salivary gland were measured before and periodically after treatment. Results: On average, the minimal dose to the primary PTVs in the conformal plans [95.2% of the prescribed dose, standard deviation (SD) 4%] was higher than in the standard plans (91%, SD 7%; p = 0.02), and target volumes receiving <95% or <90% of the prescribed dose were smaller in the conformal plans (p = 0.004 and 0.02, respectively). Similar advantages of the conformal plans compared to standard plans were found in ipsilateral jugular nodes PTV coverage. The reason for underdosing in the standard treatment plans was primarily failure of electron beams to fully encompass targets. No significant differences were found in contralateral jugular or posterior neck nodes coverage. The minimal dose to the retropharyngeal nodes was higher in the standard plans. However, all conformal plans

  4. Electronic spare-parts catalogue, an elementary module of spare-parts supply; Elektronischer Ersatzteilkatalog als elementarer Baustein der Ersatzteilversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Nienhaus, Karl; Bartnitzki, Thomas [RWTH Aachen (Germany). Inst. fuer Maschinentechnik der Rohstoffindustrie; Stoll, Andrea [Bucyrus HEX GmbH, Dortmund (Germany). Abt. Technische Dokumentation

    2011-01-15

    Developments in recent years in the supply of spare parts at Bucyrus HEX GmbH have revealed the increasing importance of quick and error-free ordering of spare parts by means of electronic spare-parts catalogues. The spare-parts catalogue has meanwhile become the central component in order to enter eCommerce with the after sales services. These higher requirements will lead to further optimisation and automation of the publishing process on the manufacturer's side and to quicker acceptance of the new digital media and the linking of the electronic spare-parts catalogues to maintenance planning systems on the customer's side. The authors agree that these are exciting times with regard to electronic spare-parts catalogues. (orig.)

  5. Parotid hybrid tumor

    International Nuclear Information System (INIS)

    Bravo C, Gustavo; Seymour M, Camila; Fernandez R, Lara; Villanueva I, Maria Elena; Scott C, Carlos; Celedon L, Carlos

    2012-01-01

    Tumors of the salivary glands represent 33%-10% of head and neck neoplasms. The most common location is the parotid gland, accounting for 50%-85% of the cases, with 20%-30% of them being malignant. The following are known to be indicative of a malignant tumor: fast growing, painless mass, associated facial paralysis and lymphadenopathy. Most parotid neoplasm derive from a single histological type but eventually the development of more than one type on the same gland can occur. This paper presents a case of a parotid neoplasm with two different histological tumors, with uncharacteristic clinical presentation. The patient presented initially with ear pain and otorrhoea, in the clinical examination highlighted an external auditory canal tumor. The complementary study revealed a parotid neoplasm and a total resection of the gland was performed. The biopsy revealed an adenoid-cystic carcinoma with differentiated basaloid areas. Adjuvant radio-chemotherapy was administered, and the imaging control with PET-CT showed no evidence of recurrence or dissemination of the tumor

  6. Differentiation between Superficial and Deep Lobe Parotid Tumors by Magnetic Resonance Imaging: Usefulness of the Parotid Duct Criterion

    Energy Technology Data Exchange (ETDEWEB)

    Imaizumi, A.; Kuribayashi, A.; Okochi, K.; Yoshino, N.; Kurabayashi, T. (Oral and Maxillofacial Radiology, Graduate School, Tokyo Medical and Dental Univ., Tokyo (Japan)); Ishii, J. (Maxillofacial Surgery, Graduate School, Tokyo Medical and Dental Univ., Tokyo (Japan)); Sumi, Y. (Division of Oral and Dental Surgery, Dept. of Advanced Medicine, National Center for Geriatrics and Gerontology, Aichi (Japan))

    2009-08-15

    Background: The location of a parotid tumor affects the choice of surgery, and there is a risk of damaging the facial nerve during surgery. Thus, differentiation between superficial and deep lobe parotid tumors is important for appropriate surgical planning. Purpose: To evaluate the usefulness of using the parotid duct, in addition to the retromandibular vein, for differentiating between superficial and deep lobe parotid tumors on MR images. Material and Methods: Magnetic resonance images of 42 parotid tumors in 40 patients were reviewed to determine whether the tumor was located in the superficial or deep lobe. In each case, the retromandibular vein and the parotid duct were used to locate the tumor. The parotid duct was only used in cases where the tumor and the duct were visualized on the same image. Results: Using the retromandibular vein criterion, 71% of deep lobe and 86% of superficial lobe tumors were correctly diagnosed, providing an accuracy of 81%. However, the accuracy achieved when using the parotid duct criterion was 100%, although it could be applied to only 28 of the 42 cases. Based on these results, we defined the following diagnostic method: the parotid duct criterion is first applied, and for cases in which it cannot be applied, the retromandibular vein criterion is used. The accuracy of this method was 88%, which was better than that achieved using the retromandibular vein criterion alone. Conclusion: The parotid duct criterion is useful for determining the location of parotid tumors. Combining the parotid duct criterion with the retromandibular vein criterion might improve the diagnostic accuracy of parotid tumor location compared to using the latter criterion alone

  7. Differentiation between Superficial and Deep Lobe Parotid Tumors by Magnetic Resonance Imaging: Usefulness of the Parotid Duct Criterion

    International Nuclear Information System (INIS)

    Imaizumi, A.; Kuribayashi, A.; Okochi, K.; Yoshino, N.; Kurabayashi, T.; Ishii, J.; Sumi, Y.

    2009-01-01

    Background: The location of a parotid tumor affects the choice of surgery, and there is a risk of damaging the facial nerve during surgery. Thus, differentiation between superficial and deep lobe parotid tumors is important for appropriate surgical planning. Purpose: To evaluate the usefulness of using the parotid duct, in addition to the retromandibular vein, for differentiating between superficial and deep lobe parotid tumors on MR images. Material and Methods: Magnetic resonance images of 42 parotid tumors in 40 patients were reviewed to determine whether the tumor was located in the superficial or deep lobe. In each case, the retromandibular vein and the parotid duct were used to locate the tumor. The parotid duct was only used in cases where the tumor and the duct were visualized on the same image. Results: Using the retromandibular vein criterion, 71% of deep lobe and 86% of superficial lobe tumors were correctly diagnosed, providing an accuracy of 81%. However, the accuracy achieved when using the parotid duct criterion was 100%, although it could be applied to only 28 of the 42 cases. Based on these results, we defined the following diagnostic method: the parotid duct criterion is first applied, and for cases in which it cannot be applied, the retromandibular vein criterion is used. The accuracy of this method was 88%, which was better than that achieved using the retromandibular vein criterion alone. Conclusion: The parotid duct criterion is useful for determining the location of parotid tumors. Combining the parotid duct criterion with the retromandibular vein criterion might improve the diagnostic accuracy of parotid tumor location compared to using the latter criterion alone

  8. A Treatment Planning Analysis of Inverse-Planned and Forward-Planned Intensity-Modulated Radiation Therapy in Nasopharyngeal Carcinoma

    International Nuclear Information System (INIS)

    Poon, Ian M; Xia Ping; Weinberg, Vivien; Sultanem, Khalil; Akazawa, Clayton C.; Akazawa, Pamela C.; Verhey, Lynn; Quivey, Jeanne Marie; Lee, Nancy

    2007-01-01

    Purpose: To compare dose-volume histograms of target volumes and organs at risk in 57 patients with nasopharyngeal carcinoma (NPC) with inverse- (IP) or forward-planned (FP) intensity-modulated radiation treatment (IMRT). Methods and Materials: The DVHs of 57 patients with NPC with IMRT with or without chemotherapy were reviewed. Thirty-one patients underwent IP IMRT, and 26 patients underwent FP IMRT. Treatment goals were to prescribe a minimum dose of 66-70 Gy for gross tumor volume and 59.4 Gy for planning target volume to greater than 95% of the volume. Multiple selected end points were used to compare dose-volume histograms of the targets, including minimum, mean, and maximum doses; percentage of target volume receiving less than 90% (1-V90%), less than 95% (1-V95%), and greater than 105% (1-V105%). Dose-volume histograms of organs at risk were evaluated with characteristic end points. Results: Both planning methods provided excellent target coverage with no statistically significant differences found, although a trend was suggested in favor of improved target coverage with IP IMRT in patients with T3/T4 NPC (p = 0.10). Overall, IP IMRT statistically decreased the dose to the parotid gland, temporomandibular joint, brain stem, and spinal cord overall, whereas IP led to a dose decrease to the middle/inner ear in only the T1/T2 subgroup. Conclusions: Use of IP and FP IMRT can lead to good target coverage while maintaining critical structures within tolerance. The IP IMRT selectively spared these critical organs to a greater degree and should be considered the standard of treatment in patients with NPC, particularly those with T3/T4. The FP IMRT is an effective second option in centers with limited IP IMRT capacity. As a modification of conformal techniques, the human/departmental resources to incorporate FP-IMRT should be nominal

  9. Prone Breast Intensity Modulated Radiation Therapy: 5-Year Results

    International Nuclear Information System (INIS)

    Osa, Etin-Osa O.; DeWyngaert, Keith; Roses, Daniel; Speyer, James; Guth, Amber; Axelrod, Deborah; Fenton Kerimian, Maria; Goldberg, Judith D.; Formenti, Silvia C.

    2014-01-01

    Purpose: To report the 5-year results of a technique of prone breast radiation therapy delivered by a regimen of accelerated intensity modulated radiation therapy with a concurrent boost to the tumor bed. Methods and Materials: Between 2003 and 2006, 404 patients with stage I-II breast cancer were prospectively enrolled into 2 consecutive protocols, institutional trials 03-30 and 05-181, that used the same regimen of 40.5 Gy/15 fractions delivered to the index breast over 3 weeks, with a concomitant daily boost to the tumor bed of 0.5 Gy (total dose 48 Gy). All patients were treated after segmental mastectomy and had negative margins and nodal assessment. Patients were set up prone: only if lung or heart volumes were in the field was a supine setup attempted and chosen if found to better spare these organs. Results: Ninety-two percent of patients were treated prone, 8% supine. Seventy-two percent had stage I, 28% stage II invasive breast cancer. In-field lung volume ranged from 0 to 228.27 cm 3 , mean 19.65 cm 3 . In-field heart volume for left breast cancer patients ranged from 0 to 21.24 cm 3 , mean 1.59 cm 3 . There was no heart in the field for right breast cancer patients. At a median follow-up of 5 years, the 5-year cumulative incidence of isolated ipsilateral breast tumor recurrence was 0.82% (95% confidence interval [CI] 0.65%-1.04%). The 5-year cumulative incidence of regional recurrence was 0.53% (95% CI 0.41%-0.69%), and the 5-year overall cumulative death rate was 1.28% (95% CI 0.48%-3.38%). Eighty-two percent (95% CI 77%-85%) of patients judged their final cosmetic result as excellent/good. Conclusions: Prone accelerated intensity modulated radiation therapy with a concomitant boost results in excellent local control and optimal sparing of heart and lung, with good cosmesis. Radiation Therapy Oncology Group protocol 1005, a phase 3, multi-institutional, randomized trial is ongoing and is evaluating the equivalence of a similar dose and fractionation

  10. Prone Breast Intensity Modulated Radiation Therapy: 5-Year Results

    Energy Technology Data Exchange (ETDEWEB)

    Osa, Etin-Osa O.; DeWyngaert, Keith [Department of Radiation Oncology, New York University School of Medicine, New York, New York (United States); Roses, Daniel [Department of Surgery, New York University School of Medicine, New York, New York (United States); Speyer, James [Department of Medical Oncology, New York University School of Medicine, New York, New York (United States); Guth, Amber; Axelrod, Deborah [Department of Surgery, New York University School of Medicine, New York, New York (United States); Fenton Kerimian, Maria [Department of Radiation Oncology, New York University School of Medicine, New York, New York (United States); Goldberg, Judith D. [Department of Population Health, New York University School of Medicine, New York, New York (United States); Formenti, Silvia C., E-mail: Silvia.formenti@nyumc.org [Department of Radiation Oncology, New York University School of Medicine, New York, New York (United States)

    2014-07-15

    Purpose: To report the 5-year results of a technique of prone breast radiation therapy delivered by a regimen of accelerated intensity modulated radiation therapy with a concurrent boost to the tumor bed. Methods and Materials: Between 2003 and 2006, 404 patients with stage I-II breast cancer were prospectively enrolled into 2 consecutive protocols, institutional trials 03-30 and 05-181, that used the same regimen of 40.5 Gy/15 fractions delivered to the index breast over 3 weeks, with a concomitant daily boost to the tumor bed of 0.5 Gy (total dose 48 Gy). All patients were treated after segmental mastectomy and had negative margins and nodal assessment. Patients were set up prone: only if lung or heart volumes were in the field was a supine setup attempted and chosen if found to better spare these organs. Results: Ninety-two percent of patients were treated prone, 8% supine. Seventy-two percent had stage I, 28% stage II invasive breast cancer. In-field lung volume ranged from 0 to 228.27 cm{sup 3}, mean 19.65 cm{sup 3}. In-field heart volume for left breast cancer patients ranged from 0 to 21.24 cm{sup 3}, mean 1.59 cm{sup 3}. There was no heart in the field for right breast cancer patients. At a median follow-up of 5 years, the 5-year cumulative incidence of isolated ipsilateral breast tumor recurrence was 0.82% (95% confidence interval [CI] 0.65%-1.04%). The 5-year cumulative incidence of regional recurrence was 0.53% (95% CI 0.41%-0.69%), and the 5-year overall cumulative death rate was 1.28% (95% CI 0.48%-3.38%). Eighty-two percent (95% CI 77%-85%) of patients judged their final cosmetic result as excellent/good. Conclusions: Prone accelerated intensity modulated radiation therapy with a concomitant boost results in excellent local control and optimal sparing of heart and lung, with good cosmesis. Radiation Therapy Oncology Group protocol 1005, a phase 3, multi-institutional, randomized trial is ongoing and is evaluating the equivalence of a similar dose and

  11. Squamous cell carcinoma originating in the parotid gland: MRI features with histopathological correlation

    International Nuclear Information System (INIS)

    Takahashi, H.; Kashiwagi, N.; Chikugo, T.; Nakanishi, K.; Tomita, Y.; Murakami, T.

    2014-01-01

    Aim: To report the magnetic resonance imaging (MRI) and corresponding histopathological features of squamous cell carcinoma (SCC) originating in the parotid gland. Materials and methods: The MRI images of seven patients with histopathologically proven SCC originating in the parotid gland were reviewed retrospectively, with an emphasis on tumour size, shape, contour definition, extraparotid infiltration, signal characteristics, and the presence of central necrosis. These were correlated with the microscopic findings of the surgical specimens. Results: The tumours ranged in size from 3.9–7 cm (mean 4.7 cm). All tumours had an ill-defined margin with extraparotid infiltration, which seemed to reflect the invasive growth of the tumour cells on histopathological examination. The solid portions of the tumours showed predominantly low to intermediate signal intensities on T2-weighted images, which seemed to reflect the high cellularity, intercellular bridges, and/or keratin pearl formation observed at histopathological examination. Five of the seven tumours had central necrosis. Conclusion: A relatively large tumour with central necrosis is a useful imaging feature of SCCs originating in the parotid gland, in addition to the well-recognized indicators of parotid malignancy, such as an ill-defined margin, extraparotid infiltration, and low to intermediate signal intensity on T2-weighted images

  12. Parotid enlargement in children with AIDS

    International Nuclear Information System (INIS)

    Soberman, N.; Leonidas, J.C.; Berdon, W.E.; Haller, J.O.; Posner, M.; Bonagura, V.

    1990-01-01

    PURPOSE: Painless parotid enlargement has been recently reported as a sign of AIDS, but little is known of the imaging characteristics of parotid involvement in affected children. The aim of this paper is to use US, CT and MR imaging to determine the anatomic changes of the parotid; study their possible association with pulmonary lymphoid hyperplasia (PLH); and define the immunologic parameters and clinical course. Eighteen children were evaluated clinically, radiologically, and immunologically. All patients underwent US of the parotids and chest radiography; some children had CT of the chest and MR imaging of the parotids

  13. Dysphagia and aspiration after chemoradiotherapy for head-and-neck cancer: which anatomic structures are affected and can they be spared by IMRT?

    NARCIS (Netherlands)

    Eisbruch, Avraham; Schwartz, Marco; Rasch, Coen; Vineberg, Karen; Damen, Eugene; van As, Corina J.; Marsh, Robin; Pameijer, Frank A.; Balm, Alfons J. M.

    2004-01-01

    PURPOSE: To identify the anatomic structures whose damage or malfunction cause late dysphagia and aspiration after intensive chemotherapy and radiotherapy (RT) for head-and-neck cancer, and to explore whether they can be spared by intensity-modulated RT (IMRT) without compromising target RT. METHODS

  14. The field-matching problem as it applies to the peacock three dimensional conformal system for intensity modulation

    International Nuclear Information System (INIS)

    Carol, Mark; Grant, Walter H.; Bleier, Alan R.; Kania, Alex A.; Targovnik, Harris S.; Butler, E. Brian; Shiao, W. Woo

    1996-01-01

    Purpose: Intensity modulated beam systems have been developed as a means of creating a high-dose region that closely conforms to the prescribed target volume while also providing specific sparing of organs at risk within complex treatment geometries. The slice-by-slice treatment paradigm used by one such system for delivering intensity modulated fields introduces regions of dose nonuniformity where each pair of treatment slices abut. A study was designed to evaluate whether or not the magnitude of the nonuniformity that results from this segmental delivery paradigm is significant relative to the overall dose nonuniformity present in the intensity modulation technique itself. An assessment was also made as to the increase in nonuniformity that would result if errors were made in indexing during treatment delivery. Methods and Materials: Treatment plans were generated to simulate correctly indexed and incorrectly indexed treatments of 4, 10, and 18 cm diameter targets. Indexing errors of from 0.1 to 2.0 mm were studied. Treatment plans were also generated for targets of the same diameter but of lengths that did not require indexing of the treatment couch. Results: The nonuniformity that results from the intensity modulation delivery paradigm is 11-16% for targets where indexing is not required. Correct indexing of the couch adds an additional 1-2% in nonuniformity. However, a couch indexing error of as little as 1 mm can increase the total nonuniformity to as much as 25%. All increases in nonuniformity from indexing are essentially independent of target diameter. Conclusions: The dose nonuniformity introduced by the segmental strip delivery paradigm is small relative to the nonuniformity present in the intensity modulation paradigm itself. A positioning accuracy of better than 0.5 mm appears to be required when implementing segmental intensity modulated treatment plans

  15. Assessment of Parotid Gland Dose Changes During Head and Neck Cancer Radiotherapy Using Daily Megavoltage Computed Tomography and Deformable Image Registration

    International Nuclear Information System (INIS)

    Lee, Choonik; Langen, Katja M.; Lu Weiguo; Haimerl, Jason; Schnarr, Eric; Ruchala, Kenneth J.; Olivera, Gustavo H.; Meeks, Sanford L.; Kupelian, Patrick A.; Shellenberger, Thomas D.; Manon, Rafael R.

    2008-01-01

    Purpose: To analyze changes in parotid gland dose resulting from anatomic changes throughout a course of radiotherapy in a cohort of head-and-neck cancer patients. Methods and Materials: The study population consisted of 10 head-and-neck cancer patients treated definitively with intensity-modulated radiotherapy on a helical tomotherapy unit. A total of 330 daily megavoltage computed tomography images were retrospectively processed through a deformable image registration algorithm to be registered to the planning kilovoltage computed tomography images. The process resulted in deformed parotid contours and voxel mappings for both daily and accumulated dose-volume histogram calculations. The daily and cumulative dose deviations from the original treatment plan were analyzed. Correlations between dosimetric variations and anatomic changes were investigated. Results: The daily parotid mean dose of the 10 patients differed from the plan dose by an average of 15%. At the end of the treatment, 3 of the 10 patients were estimated to have received a greater than 10% higher mean parotid dose than in the original plan (range, 13-42%), whereas the remaining 7 patients received doses that differed by less than 10% (range, -6-8%). The dose difference was correlated with a migration of the parotids toward the high-dose region. Conclusions: The use of deformable image registration techniques and daily megavoltage computed tomography imaging makes it possible to calculate daily and accumulated dose-volume histograms. Significant dose variations were observed as result of interfractional anatomic changes. These techniques enable the implementation of dose-adaptive radiotherapy

  16. Late toxicity and quality of life after definitive treatment of prostate cancer: redefining optimal rectal sparing constraints for intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Chennupati, Sravana K; Pelizzari, Charles A; Kunnavakkam, Rangesh; Liauw, Stanley L

    2014-01-01

    The objective of this study was to assess late toxicity and quality of life (QOL) for patients receiving definitive intensity-modulated radiotherapy (IMRT) and image-guided radiation therapy (IGRT) with regard to normal tissue sparing objectives. Three hundred and seventy-two consecutive men treated with definitive IMRT for prostate adenocarcinoma. Toxicity was graded by CTC v3.0 genitourinary (GU) and gastrointestinal (GI) toxicity at each follow-up visit. Patient-reported QOL (EPIC-26) was prospectively collected for a subset of men. Dosimetric data for bladder and rectum were compared to toxicity and QOL global domain scores, specifically analyzing outcomes for men who met ideal rectal constraints (V70 <10%, V65 <20%, V40 <40%). The median age and prescription dose was 69 years and 76 Gy, respectively. Median follow-up was 47 months. At 4 years, freedom from Grade 2 (FFG2) GI toxicity was 92% and FFG2 GU toxicity was 76%. On univariate analysis, current smoking, larger bladder volume, and higher RT dose were associated with decreased FFG2 GU toxicity, while use of anticoagulation, increasing age, and not meeting ideal rectal constraints were associated with decreased FFG2 GI toxicity (all P ≤ 0.05). Bowel QOL remained stable over the 2-year follow-up period and was higher for patients who met ideal rectal constraints (P = 0.05). IMRT with IGRT is associated with low rates of severe toxicity and a high GI and GU QOL. The use of strict rectal constraints can further improve GI QOL and reduce GI toxicity

  17. Geometric changes of parotid glands caused by hydration during chemoradiotherapy

    International Nuclear Information System (INIS)

    Kager, Petronella M.; Weerdenburg, Sanne C. C. van; Kranen, Simon R. van; Beek, Suzanne van; Lamers-Kuijper, Elisabeth A.; Heemsbergen, Wilma D.; Hamming-Vrieze, Olga; Remeijer, Peter

    2015-01-01

    Plan adaptation during the course of (chemo)radiotherapy of H&N cancer requires repeat CT scanning to capture anatomy changes such as parotid gland shrinkage. Hydration, applied to prevent nephrotoxicity from cisplatin, could temporarily alter the hydrogen balance and hence the captured anatomy. The aim of this study was to determine geometric changes of parotid glands as function of hydration during chemoradiotherapy compared to a control group treated with radiotherapy only. This study included an experimental group (n = 19) receiving chemoradiotherapy, and a control group (n = 19) receiving radiotherapy only. Chemoradiotherapy patients received cisplatin with 9 l of saline solution during hydration in the first, fourth and seventh week. The delineations of the parotid glands on the planning CT scan were automatically propagated to Cone Beam CT scans using deformable image registration. Relative volume and position of the parotid glands were determined at the second chemotherapy cycle (week four) and at fraction 35. When saline solution was administrated, the volume temporarily increased on the first day (7.2 %, p < 0.001), second day (10.8 %, p < 0.001) and third day (7.0 %, p = 0.016). The gland positions shifted lateral, the distance between glands increased on the first day with 1.5 mm (p < 0.001), on the second day 2.2 mm (p < 0.001). At fraction 35, with both groups the mean shrinkage was 24 % ± 11 % (1SD) and the mean medial distance between the parotid glands decreased by 0.47 cm ± 0.27 cm. Hydration significantly modulates parotid gland geometry. Unless, in the context of adaptive RT, a repeat CT scan is timed during a chemotherapy cycle, these effects are of minor clinical relevance

  18. [Epidemic parotiditis, a reportable disease].

    Science.gov (United States)

    Boverhoff, J C; Baart, J A

    2013-01-01

    Three consecutive patients with an acute swelling of one of the cheeks, were diagnosed with epidemic parotiditis. The first phase of the diagnostic procedure for an acute cheek swelling is to eliminate the possibility of odontogenic causes. When odontogenic problems have been excluded, non-dentition-related causes may be considered. An acute, progressive swelling in the preauricular area can often be attributed to an inflammation of the parotid gland, but epidemic parotiditis should also be considered. Epidemic parotiditis, or mumps, is caused by the mumps virus. Contamination occurs aerogenically. In the Netherlands, mumps vaccine is an ingredient of the governmental combined mump-measles-rubella inoculation programme. However, in recent years several small-scale parotiditis epidemics have broken out, predominantly among young, inoculated adults. Oropharyngeal mucus and blood samples are needed to diagnose the disease. Each case of the disease should be reported to the community healthcare service.

  19. Radiation-induced parotid gland changes in oral cancer patients. Correlation between parotid volume and saliva production

    International Nuclear Information System (INIS)

    Teshima, Keiko; Murakami, Ryuji; Tomitaka, Etsuji

    2010-01-01

    The objective of this study was to evaluate whether saliva production reflects the parotid volume during the course of radiation therapy (RT) in patients with head-and-neck cancer. Twenty patients with advanced oral squamous cell carcinomas, who were treated with preoperative chemo-RT, underwent morphological assessment with CT or MRI and functional assessment with the Saxon test. For the Saxon test, saliva production was measured by weighing a gauze pad before and 2 min after chewing without swallowing; the low-normal value is 2 g. Saliva production and parotid volumes before and 2 weeks after RT were compared with the paired t-test, the Spearman rank correlation test and the Fisher exact test. After 30 Gy irradiation, mean saliva production was decreased from 4.2 to 1.0 g (P 3 (P<0.01); the post-RT: pre-RT parotid volume ratio ranged from 54% to 85% (mean 71%). Although the initial parotid volume was correlated with initial saliva production (r=0.47, P=0.04), no significant correlation was noted after RT (r=0.08, P=0.71), and there were considerable individual variations. The parotid volume ratio was inversely correlated with the saliva-reduction amount (r=-0.79, P<0.01). There was a correlation between decreased parotid gland volume and decreased saliva production in patients with head-and-neck cancer undergoing RT. Parotid volume reduction may predict parotid gland function. (author)

  20. The study of parotid function with radionuclide imaging after radiation therapy in nasopharyngeal cancer

    International Nuclear Information System (INIS)

    Li Huanbin; Zhang Qi; Wang Ling; Wu Shixiu; Xie Congying

    2006-01-01

    Objective: To study the uptake and excretion function of parotid by radionuclide imaging after simultaneous modulated accelerated radiation therapy (SMART) in nasopharyngeal cancer. Methods: Forty-eight nasopharyngeal cancer cases, 38 of them were treated by SMART with 2.5 Gy/fraction at tumor and enlarged lymph node to a total dose of 70 Gy, and 2.0 Gy/fraction at subclinical foci and prophy laxtic area volume to a total dose of 56 Gy in 38 d. The other 10 cases were treated by traditional radiation therapy (RT). After treatment, all patients performed parotid imaging and both uptake index (UI) and excretion index (EI) after acid stimulation were calculated. Clinical manifestation such as grade of mouth dryness was also analyzed. Results: Average UI and EI in SMART group decreased 21.9% and 37.3% respectively, with 12 cases moderate and severe mouth dryness, whereas in traditional RT group, mean UI and El decreased 56.1% and 96.1% respectively, with 9 cases moderate and severe mouth dryness. There was significant difference between them (P<0.05). Conclusion: Parotid imaging is sensitive for monitoring parotid function, and it is also reliable to evaluate the safety of SMART to parotid.. (authors)

  1. FDG-PET Assessment of the Effect of Head and Neck Radiotherapy on Parotid Gland Glucose Metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Roach, Michael C. [School of Medicine, Duke University Medical Center, Duke University, Durham, NC (United States); Turkington, Timothy G. [Department of Radiology, Duke University Medical Center, Duke University, Durham, NC (United States); Department of Biomedical Engineering, Duke University Medical Center, Duke University, Durham, NC (United States); Higgins, Kristin A. [Department of Radiation Oncology, Duke University Medical Center, Duke University, Durham, NC (United States); Hawk, Thomas C. [Department of Radiology, Duke University Medical Center, Duke University, Durham, NC (United States); Hoang, Jenny K. [Department of Radiology, Duke University Medical Center, Duke University, Durham, NC (United States); Department of Radiation Oncology, Duke University Medical Center, Duke University, Durham, NC (United States); Brizel, David M., E-mail: david.brizel@duke.edu [Department of Radiation Oncology, Duke University Medical Center, Duke University, Durham, NC (United States); Department of Surgery, Duke University Medical Center, Duke University, Durham, NC (United States)

    2012-01-01

    Purpose: Functional imaging with [F-18]-fluorodeoxyglucose positron emission tomography (FDG-PET) provides the opportunity to define the physiology of the major salivary glands before and after radiation therapy. The goal of this retrospective study was to identify the radiation dose-response relationship of parotid gland glucose metabolism in patients with head and neck squamous cell carcinoma (HNSCC). Materials and Methods: Forty-nine adults with HNSCC were identified who had curative intent intensity-modulated radiation therapy (IMRT) and FDG-PET imaging before and after treatment. Using a graphical user interface, contours were delineated for the parotid glands on axial CT slices while all authors were blinded to paired PET slices. Average and maximal standard uptake values (SUV) were measured within these anatomic regions. Changes in SUV and volume after radiation therapy were correlated with parotid gland dose-volume histograms from IMRT plans. Results: The average parotid gland volume was 30.7 mL and contracted 3.9 {+-} 1.9% with every increase of 10 Gy in mean dose (p = 0.04). However, within the first 3 months after treatment, there was a uniform reduction of 16.5% {+-} 7.3% regardless of dose. The average SUV{sub mean} of the glands was 1.63 {+-} 0.48 pretreatment and declined by 5.2% {+-} 2.5% for every increase of 10 Gy in mean dose (p = 0.04). The average SUV{sub max} was 4.07 {+-} 2.85 pretreatment and decreased in a sigmoid manner with mean dose. A threshold of 32 Gy for mean dose existed, after which SUV{sub max} declined rapidly. Conclusion: Radiation dose responses of the parotid glands can be measured by integrated CT/FDG-PET scans. Retrospective analysis showed sigmoidal declines in the maximum metabolism but linear declines in the average metabolism of the glands with dose. Future studies should correlate this decline in FDG uptake with saliva production to improve treatment planning.

  2. REPLACEMENT SPARE PART INVENTORY MONITORING USING ADAPTIVE NEURO FUZZY INFERENCE SYSTEM

    Directory of Open Access Journals (Sweden)

    Hartono Hartono

    2016-01-01

    Full Text Available Abstract   The amount of inventory is determined on the basis of the demand. So that users can know the demand forecasts need to be done on the request. This study uses the data to implement a replacement parts on the electronic module production equipment in the telecommunications transmission systems, switching, access and power, ie by replacing the electronic module in the system is trouble  or damaged parts of a good electronic module spare parts inventory, while the faulty electronic modules shipped to the Repair Center for repaired again, so that the results of these improvements can replenish spare part  inventory. Parameters speed on improvement process of electronic module broken (repaired, in the form of an average repair time at the repair centers, in order to get back into the electronic module that is ready for used as spare parts in compliance with the safe supply inventory  warehouse.  This research using the method  of  Adaptive Neuro Fuzzy Inference System (ANFIS in developing a decision support system for inventory control of spare parts available in Warehouse Inventory taking into account several parameters supporters, namely demand, improvement and fulfillment of spare parts and repair time. This study uses a recycling input parameter repair faulty electronic module of the customer to immediately replace the module in inventory warehouse,  do improvements in the Repair Center. So the acceleration restoration factor is very influential as the input spare parts inventory supply in the warehouse and using the Adaptive Neuro-Fuzzy Inference System (ANFIS method.   Keywords: ANFIS, inventory control, replacement

  3. Diagnostic value of magnetic resonance imaging and the pathologic basis of parotid Warthin's tumor in 46 cases

    International Nuclear Information System (INIS)

    Yuan Jianpeng; Huang Suiqiao; Xie Bangkun; Zhong Jinglian; Li Yong

    2004-01-01

    Objective: To summarize MR manifestations of parotid Warthin's tumor and to investigate their pathological fundament. MR findings of parotid Warthin's tumor including shape, margin, signal intensity on T 1 WI and T 2 WI, homogeneity of the signal, enhancement were analyzed retrospectively in this study. Methods: In total 46 cases (54 lesions) of parotid Warthin's tumor proved by surgery were enrolled. MRI manifestations were comparatively studied with pathological findings. T 1 WI and T 2 WI sequence were used in non-contrast scan, while both non-contrast and enhanced scan were performed in 50 lesions out of 54. Results: The shapes of Warthin's tumor were regular (51/54); the edges were clear (54/54); more than half of the lesions (33/54) presented with low or equal signal intensity on T 2 WI; 50 Warthin's tumors enhanced slightly. The MR features of Warthin's tumors were different from pleomorphic adenoma and other parotid benign tumors. Conclusion: There are certain characteristics of Warthin's tumors on MR images, and these are helpful in determining the histological nature of the tumor

  4. Delivery confirmation of bolus electron conformal therapy combined with intensity modulated x-ray therapy

    International Nuclear Information System (INIS)

    Kavanaugh, James A.; Hogstrom, Kenneth R.; Fontenot, Jonas P.; Henkelmann, Gregory; Chu, Connel; Carver, Robert A.

    2013-01-01

    Purpose: The purpose of this study was to demonstrate that a bolus electron conformal therapy (ECT) dose plan and a mixed beam plan, composed of an intensity modulated x-ray therapy (IMXT) dose plan optimized on top of the bolus ECT plan, can be accurately delivered. Methods: Calculated dose distributions were compared with measured dose distributions for parotid and chest wall (CW) bolus ECT and mixed beam plans, each simulated in a cylindrical polystyrene phantom that allowed film dose measurements. Bolus ECT plans were created for both parotid and CW PTVs (planning target volumes) using 20 and 16 MeV beams, respectively, whose 90% dose surface conformed to the PTV. Mixed beam plans consisted of an IMXT dose plan optimized on top of the bolus ECT dose plan. The bolus ECT, IMXT, and mixed beam dose distributions were measured using radiographic films in five transverse and one sagittal planes for a total of 36 measurement conditions. Corrections for film dose response, effects of edge-on photon irradiation, and effects of irregular phantom optical properties on the Cerenkov component of the film signal resulted in high precision measurements. Data set consistency was verified by agreement of depth dose at the intersections of the sagittal plane with the five measured transverse planes. For these same depth doses, results for the mixed beam plan agreed with the sum of the individual depth doses for the bolus ECT and IMXT plans. The six mean measured planar dose distributions were compared with those calculated by the treatment planning system for all modalities. Dose agreement was assessed using the 4% dose difference and 0.2 cm distance to agreement. Results: For the combined high-dose region and low-dose region, pass rates for the parotid and CW plans were 98.7% and 96.2%, respectively, for the bolus ECT plans and 97.9% and 97.4%, respectively, for the mixed beam plans. For the high-dose gradient region, pass rates for the parotid and CW plans were 93.1% and 94

  5. Perfusion characteristics of parotid gland tumors evaluated by contrast-enhanced ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Klotz, Laura V., E-mail: Laura.Klotz@med.uni-muenchen.de [Department of Surgery, University of Munich, Munich (Germany); Gürkov, Robert [Department of Otorhinolaryngology, University of Munich, Munich (Germany); Eichhorn, Martin E. [Department of Surgery, University of Munich, Munich (Germany); Siedek, Vanessa; Krause, Eike [Department of Otorhinolaryngology, University of Munich, Munich (Germany); Jauch, Karl-Walter [Department of Surgery, University of Munich, Munich (Germany); Reiser, Maximilian F.; Clevert, Dirk-Andre [Department of Clinical Radiology, University of Munich, Munich (Germany)

    2013-12-01

    Purpose: Contrast enhanced ultrasound (CE-US) is a promising imaging modality for non-invasive analysis of parotid gland lesions because their vascularisation differs from normal gland tissue. This clinical study should further investigate CE-US as a diagnostic tool for parotid gland tumors. Materials and methods: 39 patients underwent CE-US measurements after intravenous application of a contrast agent (SonoVue, Bracco, Italy) before surgical tumor resection. Time–intensity curves gradients were calculated and parameters of intratumoral microcirculation were analysed. The vascularisation parameters were compared among the different tumor entities as defined per definitive histological diagnosis. Results: Histological analyses revealed 17 pleomorphic adenoma, 15 cystadenolymphoma and 7 malignoma. A significant difference of area below intensity time curve (AUC) and mean transit time (MTT) was measured in the malignant lesions compared to benign tumors (p < 0.05). A significant difference of AUC and maximum of signal increase (ΔSI{sub max}) for pleomorphic adenoma versus cystadenolymphoma was found (p < 0.05). Conclusion: CE-US seems to be a quantitative and independent method for the assessment of malign and benign parotid gland tumors. Further studies and clinical experience will have to validate this method as a reliable diagnostic tool that facilitates preoperative planning.

  6. Warthin's Tumor of the Parotid Gland: CT and MR Features

    International Nuclear Information System (INIS)

    Lee, Yun Hee; Yu, In Kyu; Lee, Byung Hee; Kim, Min Sun; Han, Moon Hee; Song, Chang Joon

    2009-01-01

    In this study, we have evaluated the imaging features of Warthin's tumor of the parotid gland with the use of CT and MR imaging. CT (n = 30) and MR (n = 7) images of 26 patients (M:F=23:3; age range, 38-76 years; mean age, 58 years) with surgically-proven Warthin's tumor (n = 37) were reviewed with a focus on bilaterality, multiplicity, location, size, demarcation, margin, enhancement pattern and MR signal intensity. Lesions were bilateral in seven patients (27%), multiple in nine patients (35%) and unilateral multiple in four patients (15%). Tumors were located in the superficial lobe (65%), deep lobe (24%) and both lobes (11%) of the parotid gland. Most tumors had a clear (95%) and smooth margin (95%) with a round or oval shape. Tumors mainly showed a solid and cystic composition (n = 24, 65%) and all solid stroma showed poor or weak enhancement on both CT and MR images. Papillary projections from the peripheral wall were clearly seen (n = 6, 86%). Warthin's tumor is frequently seen in the parotid superficial lobe of older males with a higher bilateral and multiple tendency. Warthin's tumor shows cystic portions with papillary projections at the wall on CT images and focal high signal intensity (SI) on T1-weighted images with dense nodular enhancement on MR images

  7. Evaluating Intensity Modulated Proton Therapy Relative to Passive Scattering Proton Therapy for Increased Vertebral Column Sparing in Craniospinal Irradiation in Growing Pediatric Patients

    International Nuclear Information System (INIS)

    Giantsoudi, Drosoula; Seco, Joao; Eaton, Bree R.; Simeone, F. Joseph; Kooy, Hanne; Yock, Torunn I.; Tarbell, Nancy J.; DeLaney, Thomas F.; Adams, Judith; Paganetti, Harald; MacDonald, Shannon M.

    2017-01-01

    Purpose: At present, proton craniospinal irradiation (CSI) for growing children is delivered to the whole vertebral body (WVB) to avoid asymmetric growth. We aimed to demonstrate the feasibility and potential clinical benefit of delivering vertebral body sparing (VBS) versus WVB CSI with passively scattered (PS) and intensity modulated proton therapy (IMPT) in growing children treated for medulloblastoma. Methods and Materials: Five plans were generated for medulloblastoma patients, who had been previously treated with CSI PS proton radiation therapy: (1) single posteroanterior (PA) PS field covering the WVB (PS-PA-WVB); (2) single PA PS field that included only the thecal sac in the target volume (PS-PA-VBS); (3) single PA IMPT field covering the WVB (IMPT-PA-WVB); (4) single PA IMPT field, target volume including thecal sac only (IMPT-PA-VBS); and (5) 2 posterior-oblique (−35°, +35°) IMPT fields, with the target volume including the thecal sac only (IMPT2F-VBS). For all cases, 23.4 Gy (relative biologic effectiveness [RBE]) was prescribed to 95% of the spinal canal. The dose, linear energy transfer, and variable-RBE-weighted dose distributions were calculated for all plans using the tool for particle simulation, version 2, Monte Carlo system. Results: IMPT VBS techniques efficiently spared the anterior vertebral bodies (AVBs), even when accounting for potential higher variable RBE predicted by linear energy transfer distributions. Assuming an RBE of 1.1, the V10 Gy(RBE) decreased from 100% for the WVB techniques to 59.5% to 76.8% for the cervical, 29.9% to 34.6% for the thoracic, and 20.6% to 25.1% for the lumbar AVBs, and the V20 Gy(RBE) decreased from 99.0% to 17.8% to 20.0% for the cervical, 7.2% to 7.6% for the thoracic, and 4.0% to 4.6% for the lumbar AVBs when IMPT VBS techniques were applied. The corresponding percentages for the PS VBS technique were higher. Conclusions: Advanced proton techniques can sufficiently reduce the dose to the vertebral

  8. Evaluating Intensity Modulated Proton Therapy Relative to Passive Scattering Proton Therapy for Increased Vertebral Column Sparing in Craniospinal Irradiation in Growing Pediatric Patients

    Energy Technology Data Exchange (ETDEWEB)

    Giantsoudi, Drosoula, E-mail: dgiantsoudi@mgh.harvard.edu; Seco, Joao; Eaton, Bree R.; Simeone, F. Joseph; Kooy, Hanne; Yock, Torunn I.; Tarbell, Nancy J.; DeLaney, Thomas F.; Adams, Judith; Paganetti, Harald; MacDonald, Shannon M.

    2017-05-01

    Purpose: At present, proton craniospinal irradiation (CSI) for growing children is delivered to the whole vertebral body (WVB) to avoid asymmetric growth. We aimed to demonstrate the feasibility and potential clinical benefit of delivering vertebral body sparing (VBS) versus WVB CSI with passively scattered (PS) and intensity modulated proton therapy (IMPT) in growing children treated for medulloblastoma. Methods and Materials: Five plans were generated for medulloblastoma patients, who had been previously treated with CSI PS proton radiation therapy: (1) single posteroanterior (PA) PS field covering the WVB (PS-PA-WVB); (2) single PA PS field that included only the thecal sac in the target volume (PS-PA-VBS); (3) single PA IMPT field covering the WVB (IMPT-PA-WVB); (4) single PA IMPT field, target volume including thecal sac only (IMPT-PA-VBS); and (5) 2 posterior-oblique (−35°, +35°) IMPT fields, with the target volume including the thecal sac only (IMPT2F-VBS). For all cases, 23.4 Gy (relative biologic effectiveness [RBE]) was prescribed to 95% of the spinal canal. The dose, linear energy transfer, and variable-RBE-weighted dose distributions were calculated for all plans using the tool for particle simulation, version 2, Monte Carlo system. Results: IMPT VBS techniques efficiently spared the anterior vertebral bodies (AVBs), even when accounting for potential higher variable RBE predicted by linear energy transfer distributions. Assuming an RBE of 1.1, the V10 Gy(RBE) decreased from 100% for the WVB techniques to 59.5% to 76.8% for the cervical, 29.9% to 34.6% for the thoracic, and 20.6% to 25.1% for the lumbar AVBs, and the V20 Gy(RBE) decreased from 99.0% to 17.8% to 20.0% for the cervical, 7.2% to 7.6% for the thoracic, and 4.0% to 4.6% for the lumbar AVBs when IMPT VBS techniques were applied. The corresponding percentages for the PS VBS technique were higher. Conclusions: Advanced proton techniques can sufficiently reduce the dose to the vertebral

  9. Patient geometry-driven information retrieval for IMRT treatment plan quality control

    International Nuclear Information System (INIS)

    Wu Binbin; Ricchetti, Francesco; Sanguineti, Giuseppe; Kazhdan, Misha; Simari, Patricio; Chuang Ming; Taylor, Russell; Jacques, Robert; McNutt, Todd

    2009-01-01

    Purpose: Intensity modulated radiation therapy (IMRT) treatment plan quality depends on the planner's level of experience and the amount of time the planner invests in developing the plan. Planners often unwittingly accept plans when further sparing of the organs at risk (OARs) is possible. The authors propose a method of IMRT treatment plan quality control that helps planners to evaluate the doses of the OARs upon completion of a new plan. Methods: It is achieved by comparing the geometric configurations of the OARs and targets of a new patient with those of prior patients, whose plans are maintained in a database. They introduce the concept of a shape relationship descriptor and, specifically, the overlap volume histogram (OVH) to describe the spatial configuration of an OAR with respect to a target. The OVH provides a way to infer the likely DVHs of the OARs by comparing the relative spatial configurations between patients. A database of prior patients is built to serve as an external reference. At the conclusion of a new plan, planners search through the database and identify related patients by comparing the OAR-target geometric relationships of the new patient with those of prior patients. The treatment plans of these related patients are retrieved from the database and guide planners in determining whether lower doses delivered to the OARs in the new plan are feasible. Results: Preliminary evaluation is promising. In this evaluation, they applied the analysis to the parotid DVHs of 32 prior head-and-neck patients, whose plans are maintained in a database. Each parotid was queried against the other 63 parotids to determine whether a lower dose was possible. The 17 parotids that promised the greatest reduction in D 50 (DVH dose at 50% volume) were flagged. These 17 parotids came from 13 patients. The method also indicated that the doses of the other nine parotids of the 13 patients could not be reduced, so they were included in the replanning process as

  10. TH-E-BRF-09: Gaussian Mixture Model Analysis of Radiation-Induced Parotid-Gland Injury: An Ultrasound Study of Acute and Late Xerostomia in Head-And-Neck Radiotherapy

    International Nuclear Information System (INIS)

    Liu, T; Yu, D; Beitler, J; Curran, W; Yang, X; Tridandapani, S; Bruner, D

    2014-01-01

    Purpose: Xerostomia (dry mouth), secondary to parotid-gland injury, is a distressing side-effect in head-and-neck radiotherapy (RT). This study's purpose is to develop a novel ultrasound technique to quantitatively evaluate post-RT parotid-gland injury. Methods: Recent ultrasound studies have shown that healthy parotid glands exhibit homogeneous echotexture, whereas post-RT parotid glands are often heterogeneous, with multiple hypoechoic (inflammation) or hyperechoic (fibrosis) regions. We propose to use a Gaussian mixture model to analyze the ultrasonic echo-histogram of the parotid glands. An IRB-approved clinical study was conducted: (1) control-group: 13 healthy-volunteers, served as the control; (2) acutetoxicity group − 20 patients (mean age: 62.5 ± 8.9 years, follow-up: 2.0±0.8 months); and (3) late-toxicity group − 18 patients (mean age: 60.7 ± 7.3 years, follow-up: 20.1±10.4 months). All patients experienced RTOG grade 1 or 2 salivary-gland toxicity. Each participant underwent an ultrasound scan (10 MHz) of the bilateral parotid glands. An echo-intensity histogram was derived for each parotid and a Gaussian mixture model was used to fit the histogram using expectation maximization (EM) algorithm. The quality of the fitting was evaluated with the R-squared value. Results: (1) Controlgroup: all parotid glands fitted well with one Gaussian component, with a mean intensity of 79.8±4.9 (R-squared>0.96). (2) Acute-toxicity group: 37 of the 40 post-RT parotid glands fitted well with two Gaussian components, with a mean intensity of 42.9±7.4, 73.3±12.2 (R-squared>0.95). (3) Latetoxicity group: 32 of the 36 post-RT parotid fitted well with 3 Gaussian components, with mean intensities of 49.7±7.6, 77.2±8.7, and 118.6±11.8 (R-squared>0.98). Conclusion: RT-associated parotid-gland injury is common in head-and-neck RT, but challenging to assess. This work has demonstrated that the Gaussian mixture model of the echo-histogram could quantify acute and

  11. TH-E-BRF-09: Gaussian Mixture Model Analysis of Radiation-Induced Parotid-Gland Injury: An Ultrasound Study of Acute and Late Xerostomia in Head-And-Neck Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, T [Department of Radiation Oncology and Winship Cancer Institute, Emory Univ, Atlanta, GA (United States); Yu, D; Beitler, J; Curran, W; Yang, X [Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA (United States); Tridandapani, S [Department of Radiology and Imaging Sciences and Winship Cancer Institute, Emory University, Atlanta, GA (United States); Bruner, D [School of Nursing and Winship Cancer Institute, Emory Univesity, Atlanta, GA (United States)

    2014-06-15

    Purpose: Xerostomia (dry mouth), secondary to parotid-gland injury, is a distressing side-effect in head-and-neck radiotherapy (RT). This study's purpose is to develop a novel ultrasound technique to quantitatively evaluate post-RT parotid-gland injury. Methods: Recent ultrasound studies have shown that healthy parotid glands exhibit homogeneous echotexture, whereas post-RT parotid glands are often heterogeneous, with multiple hypoechoic (inflammation) or hyperechoic (fibrosis) regions. We propose to use a Gaussian mixture model to analyze the ultrasonic echo-histogram of the parotid glands. An IRB-approved clinical study was conducted: (1) control-group: 13 healthy-volunteers, served as the control; (2) acutetoxicity group − 20 patients (mean age: 62.5 ± 8.9 years, follow-up: 2.0±0.8 months); and (3) late-toxicity group − 18 patients (mean age: 60.7 ± 7.3 years, follow-up: 20.1±10.4 months). All patients experienced RTOG grade 1 or 2 salivary-gland toxicity. Each participant underwent an ultrasound scan (10 MHz) of the bilateral parotid glands. An echo-intensity histogram was derived for each parotid and a Gaussian mixture model was used to fit the histogram using expectation maximization (EM) algorithm. The quality of the fitting was evaluated with the R-squared value. Results: (1) Controlgroup: all parotid glands fitted well with one Gaussian component, with a mean intensity of 79.8±4.9 (R-squared>0.96). (2) Acute-toxicity group: 37 of the 40 post-RT parotid glands fitted well with two Gaussian components, with a mean intensity of 42.9±7.4, 73.3±12.2 (R-squared>0.95). (3) Latetoxicity group: 32 of the 36 post-RT parotid fitted well with 3 Gaussian components, with mean intensities of 49.7±7.6, 77.2±8.7, and 118.6±11.8 (R-squared>0.98). Conclusion: RT-associated parotid-gland injury is common in head-and-neck RT, but challenging to assess. This work has demonstrated that the Gaussian mixture model of the echo-histogram could quantify acute and

  12. Intensity-Modulated Whole Abdominal Radiotherapy After Surgery and Carboplatin/Taxane Chemotherapy for Advanced Ovarian Cancer: Phase I Study

    International Nuclear Information System (INIS)

    Rochet, Nathalie; Sterzing, Florian; Jensen, Alexandra D.; Dinkel, Julien; Herfarth, Klaus K.; Schubert, Kai; Eichbaum, Michael H.; Schneeweiss, Andreas; Sohn, Christof; Debus, Juergen; Harms, Wolfgang

    2010-01-01

    Purpose: To assess the feasibility and toxicity of consolidative intensity-modulated whole abdominal radiotherapy (WAR) after surgery and chemotherapy in high-risk patients with advanced ovarian cancer. Methods and Materials: Ten patients with optimally debulked ovarian cancer International Federation of Gynecology and Obstetrics Stage IIIc were treated in a Phase I study with intensity-modulated WAR up to a total dose of 30 Gy in 1.5-Gy fractions as consolidation therapy after adjuvant carboplatin/taxane chemotherapy. Treatment was delivered using intensity-modulated radiotherapy in a step-and-shoot technique (n = 3) or a helical tomotherapy technique (n = 7). The planning target volume included the entire peritoneal cavity and the pelvic and para-aortal node regions. Organs at risk were kidneys, liver, heart, vertebral bodies, and pelvic bones. Results: Intensity-modulated WAR resulted in an excellent coverage of the planning target volume and an effective sparing of the organs at risk. The treatment was well tolerated, and no severe Grade 4 acute side effects occurred. Common Toxicity Criteria Grade III toxicities were as follows: diarrhea (n = 1), thrombocytopenia (n = 1), and leukopenia (n = 3). Radiotherapy could be completed by all the patients without any toxicity-related interruption. Median follow-up was 23 months, and 4 patients had tumor recurrence (intraperitoneal progression, n = 3; hepatic metastasis, n = 1). Small bowel obstruction caused by adhesions occurred in 3 patients. Conclusions: The results of this Phase I study showed for the first time, to our knowledge, the clinical feasibility of intensity-modulated whole abdominal radiotherapy, which could offer a new therapeutic option for consolidation treatment of advanced ovarian carcinoma after adjuvant chemotherapy in selected subgroups of patients. We initiated a Phase II study to further evaluate the toxicity of this intensive multimodal treatment.

  13. Intensity-modulated whole abdominal radiotherapy after surgery and carboplatin/taxane chemotherapy for advanced ovarian cancer: phase I study.

    Science.gov (United States)

    Rochet, Nathalie; Sterzing, Florian; Jensen, Alexandra D; Dinkel, Julien; Herfarth, Klaus K; Schubert, Kai; Eichbaum, Michael H; Schneeweiss, Andreas; Sohn, Christof; Debus, Juergen; Harms, Wolfgang

    2010-04-01

    To assess the feasibility and toxicity of consolidative intensity-modulated whole abdominal radiotherapy (WAR) after surgery and chemotherapy in high-risk patients with advanced ovarian cancer. Ten patients with optimally debulked ovarian cancer International Federation of Gynecology and Obstetrics Stage IIIc were treated in a Phase I study with intensity-modulated WAR up to a total dose of 30 Gy in 1.5-Gy fractions as consolidation therapy after adjuvant carboplatin/taxane chemotherapy. Treatment was delivered using intensity-modulated radiotherapy in a step-and-shoot technique (n = 3) or a helical tomotherapy technique (n = 7). The planning target volume included the entire peritoneal cavity and the pelvic and para-aortal node regions. Organs at risk were kidneys, liver, heart, vertebral bodies, and pelvic bones. Intensity-modulated WAR resulted in an excellent coverage of the planning target volume and an effective sparing of the organs at risk. The treatment was well tolerated, and no severe Grade 4 acute side effects occurred. Common Toxicity Criteria Grade III toxicities were as follows: diarrhea (n = 1), thrombocytopenia (n = 1), and leukopenia (n = 3). Radiotherapy could be completed by all the patients without any toxicity-related interruption. Median follow-up was 23 months, and 4 patients had tumor recurrence (intraperitoneal progression, n = 3; hepatic metastasis, n = 1). Small bowel obstruction caused by adhesions occurred in 3 patients. The results of this Phase I study showed for the first time, to our knowledge, the clinical feasibility of intensity-modulated whole abdominal radiotherapy, which could offer a new therapeutic option for consolidation treatment of advanced ovarian carcinoma after adjuvant chemotherapy in selected subgroups of patients. We initiated a Phase II study to further evaluate the toxicity of this intensive multimodal treatment.

  14. Intensity modulated radiotherapy for elderly bladder cancer patients

    International Nuclear Information System (INIS)

    Hsieh, Chen-Hsi; Wang, Li-Ying; Hsieh, Yen-Ping; Shueng, Pei-Wei; Chung, Shiu-Dong; Chan, Pei-Hui; Lai, Siu-Kai; Chang, Hsiao-Chun; Hsiao, Chi-Huang; Wu, Le-Jung; Chong, Ngot-Swan; Chen, Yu-Jen

    2011-01-01

    To review our experience and evaluate treatment planning using intensity-modulated radiotherapy (IMRT) and helical tomotherapy (HT) for the treatment of elderly patients with bladder cancer. From November 2006 through November 2009, we enrolled 19 elderly patients with histologically confirmed bladder cancer, 9 in the IMRT and 10 in the HT group. The patients received 64.8 Gy to the bladder with or without concurrent chemotherapy. Conventional 4-field 'box' pelvic radiation therapy (2DRT) plans were generated for comparison. The median patient age was 80 years old (range, 65-90 years old). The median survival was 21 months (5 to 26 months). The actuarial 2-year overall survival (OS) for the IMRT vs. the HT group was 26.3% vs .37.5%, respectively; the corresponding values for disease-free survival were 58.3% vs. 83.3%, respectively; for locoregional progression-free survival (LRPFS), the values were 87.5% vs. 83.3%, respectively; and for metastases-free survival, the values were 66.7% vs. 60.0%, respectively. The 2-year OS rates for T1, 2 vs. T3, 4 were 66.7% vs. 35.4%, respectively (p = 0.046). The 2-year OS rate was poor for those whose RT completion time greater than 8 weeks when compared with the RT completed within 8 wks (37.9% vs. 0%, p = 0.004). IMRT and HT provide good LRPFS with tolerable toxicity for elderly patients with invasive bladder cancer. IMRT and HT dosimetry and organ sparing capability were superior to that of 2DRT, and HT provides better sparing ability than IMRT. The T category and the RT completion time influence OS rate

  15. Unilateral Duplication Of Parotid Duct. A Rare Anatomical Variation

    Directory of Open Access Journals (Sweden)

    Humberto Ferreira Arquez

    2017-11-01

    Full Text Available Background: The paired parotid glands are the largest of the major salivary glands and produces mainly serous secretions. The secretion of this gland reaches the oral cavity through single parotid duct (Stensen’s duct. The parotid duct begins at the anterior border of the gland, crosses the masseter muscle, and then pierces the buccinator muscle to reach the mucosa lining the mouth at the level of the cheek. The purpose of this study is determine the morphologic features of the parotid duct and describe an anatomical variation until now unreported. Methods and Findings: A total of 17 cadavers were used for this study in the Morphology Laboratory at the University of Pamplona. In a cadaver were findings: The main parotid duct originated two conducts: Left superior parotid duct and Left inferior parotid duct, is observed the criss-cross of the ducts, and then perforated the buccinator muscle and entered the oral cavity at a double parotid papilla containing a double opening, separated from each other in 0,98 mm. In the remaining  33 parotid regions (97.06% the parotid duct is conformed to the classical descriptions given in anatomical textbooks. Conclusions: The parotid duct anatomy is important for duct endoscopy, lithotripsy, sialography and trans-ductal facial nerve stimulation in the early stage of facial palsy in some cases. The anatomical variations also has clinical importance for parotid gland surgery and facial cosmetic surgery. To keep in mind the parotid duct variation will reduce iatrogenic injury risks and improve diagnosis of parotid duct injury.

  16. Dependence of Achievable Plan Quality on Treatment Technique and Planning Goal Refinement: A Head-and-Neck Intensity Modulated Radiation Therapy Application

    International Nuclear Information System (INIS)

    Qi, X. Sharon; Ruan, Dan; Lee, Steve P.; Pham, Andrew; Kupelian, Patrick; Low, Daniel A.; Steinberg, Michael; Demarco, John

    2015-01-01

    Purpose: To develop a practical workflow for retrospectively analyzing target and normal tissue dose–volume endpoints for various intensity modulated radiation therapy (IMRT) delivery techniques; to develop technique-specific planning goals to improve plan consistency and quality when feasible. Methods and Materials: A total of 165 consecutive head-and-neck patients from our patient registry were selected and retrospectively analyzed. All IMRT plans were generated using the same dose–volume guidelines for TomoTherapy (Tomo, Accuray), TrueBeam (TB, Varian) using fixed-field IMRT (TB-IMRT) or RAPIDARC (TB-RAPIDARC), or Siemens Oncor (Siemens-IMRT, Siemens). A MATLAB-based dose–volume extraction and analysis tool was developed to export dosimetric endpoints for each patient. With a fair stratification of patient cohort, the variation of achieved dosimetric endpoints was analyzed among different treatment techniques. Upon identification of statistically significant variations, technique-specific planning goals were derived from dynamically accumulated institutional data. Results: Retrospective analysis showed that although all techniques yielded comparable target coverage, the doses to the critical structures differed. The maximum cord doses were 34.1 ± 2.6, 42.7 ± 2.1, 43.3 ± 2.0, and 45.1 ± 1.6 Gy for Tomo, TB-IMRT, TB-RAPIDARC, and Siemens-IMRT plans, respectively. Analyses of variance showed significant differences for the maximum cord doses but no significant differences for other selected structures among the investigated IMRT delivery techniques. Subsequently, a refined technique-specific dose–volume guideline for maximum cord dose was derived at a confidence level of 95%. The dosimetric plans that failed the refined technique-specific planning goals were reoptimized according to the refined constraints. We observed better cord sparing with minimal variations for the target coverage and other organ at risk sparing for the Tomo cases, and higher

  17. Magnetic resonance imaging of parotid tumors, 1

    International Nuclear Information System (INIS)

    Nakamura, Akihiko; Yamashita, Toshio; Inoue, Toshiya; Kumazawa, Tadami; Kato, Tsutomu; Sawada, Satoshi; Tanaka, Yoshimasa

    1987-01-01

    We compared the usefulness of magnetic resonance imaging (MRI), with that of X-ray computed tomography in the preoperative diagnosis of parotid tumors. We performed in 13 patients with parotid tumors and 10 of them were operated. The MRI equipment had a magnetic fild of 0.15 Tesla. We used the spine echo acquisition technique and a repetition time of 600, 1000 and 2000 milli-seconds, and echo time of 40 and 80 milli-seconds. We found that the T 1 weighted image well visualized the duct of the parotid gland, the T 2 weighted image provided fine pictures of the parotid tumor. The facial nerve of normal parotid glands could not be visualized by MRI. (author)

  18. BENEFITS OF INTENSITY-MODULATED RADIOTHERAPY (IMRT IN PATIENTS WITH HEAD AND NECK MALIGNANCIES- A SINGLE INSTITUTION EXPERIENCE

    Directory of Open Access Journals (Sweden)

    Sherry Seasor Abraham

    2017-09-01

    Full Text Available BACKGROUND Radiotherapy and surgery are the principal curative modalities in treatment of head and neck cancer. Conventional twodimensional and three-dimensional conformal radiotherapy result in significant side effects and altered quality of life. IntensityModulated Radiotherapy (IMRT can spare the normal tissues, while delivering a curative dose to the tumour-bearing tissues. This study reveals the role of IMRT in head and neck cancer in view of normal tissue sparing with good tumour control. MATERIALS AND METHODS Radical radiotherapy was given using linear accelerator up to a dose of 66 to 70 gray in 30 to 33 fractions (intensity-modulated radiotherapy with simultaneous integrated boost over 6 to 7 weeks to 56 eligible patients. Concurrent cisplatin was given to patients with locally-advanced disease up to a dose of 40 mg/m2 weekly once along with radiation. The patients were monitored weekly once during the treatment for acute skin and mucosal toxicities using the RTOG scoring criteria. After the treatment, locoregional response was assessed and recorded at 6 weeks, 3 months and 6 months intervals. RESULTS Severe skin toxicity (grade III or more was seen in approximately 7% patients. Severe mucosal toxicity (grade III or more was seen in approximately 80% of patients. IMRT technique showed better skin sparing compared to 3D conformal radiotherapy. Severe mucosal toxicity was slightly higher in this study due to the simultaneous integrated boost technique used for dose intensification to the mucosa, which results in better primary tumour control. At the end of 6 months, 75% patients achieved locoregional control and residual/recurrent disease was seen in 25% of patients. IMRT offered good locoregional control with less skin toxicity and acceptable mucosal toxicity. The results were similar to the previous study reports using IMRT. CONCLUSION IMRT is a better treatment option in locally-advanced head and neck malignancies providing good

  19. Improved Beam Angle Arrangement in Intensity Modulated Proton Therapy Treatment Planning for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Cao, Wenhua; Lim, Gino J.; Li, Yupeng; Zhu, X. Ronald; Zhang, Xiaodong

    2015-01-01

    Purpose: This study investigates potential gains of an improved beam angle arrangement compared to a conventional fixed gantry setup in intensity modulated proton therapy (IMPT) treatment for localized prostate cancer patients based on a proof of principle study. Materials and Methods: Three patients with localized prostate cancer retrospectively selected from our institution were studied. For each patient, IMPT plans were designed using two, three and four beam angles, respectively, obtained from a beam angle optimization algorithm. Those plans were then compared with ones using two lateral parallel-opposed beams according to the conventional planning protocol for localized prostate cancer adopted at our institution. Results: IMPT plans with two optimized angles achieved significant improvements in rectum sparing and moderate improvements in bladder sparing against those with two lateral angles. Plans with three optimized angles further improved rectum sparing significantly over those two-angle plans, whereas four-angle plans found no advantage over three-angle plans. A possible three-beam class solution for localized prostate patients was suggested and demonstrated with preserved dosimetric benefits because individually optimized three-angle solutions were found sharing a very similar pattern. Conclusions: This study has demonstrated the potential of using an improved beam angle arrangement to better exploit the theoretical dosimetric benefits of proton therapy and provided insights of selecting quality beam angles for localized prostate cancer treatment

  20. Parotid lymphomas - clinical and computed tomogrphic imaging ...

    African Journals Online (AJOL)

    Objective. To review the clinical presentation and computed tomography (CT) imaging characteristics of all parotid lymphomas diagnosed at the study institution over a 7-year period. Design. Retrospective chart review of parotid lymphomas diagnosed between 1997 and 2004. Subjects. A total of 121 patients with parotid ...

  1. Comparison of volumetric modulated arc therapy and intensity modulated radiation therapy for whole brain hippocampal sparing treatment plans based on radiobiological modeling

    Directory of Open Access Journals (Sweden)

    Ethan Kendall

    2018-01-01

    Full Text Available Introduction: In this article, we report the results of our investigation on comparison of radiobiological aspects of treatment plans with linear accelerator-based intensity-modulated radiation therapy and volumetric-modulated arc therapy for patients having hippocampal avoidance whole-brain radiation therapy. Materials and Methods: In this retrospective study using the dose-volume histogram, we calculated and compared biophysical indices of equivalent uniform dose, tumor control probability, and normal tissue complication probability (NTCP for 15 whole-brain radiotherapy patients. Results and Discussions: Dose-response models for tumors and critical structures were separated into two groups: mechanistic and empirical. Mechanistic models formulate mathematically with describable relationships while empirical models fit data through empirical observations to appropriately determine parameters giving results agreeable to those given by mechanistic models. Conclusions: Techniques applied in this manuscript could be applied to any other organs or types of cancer to evaluate treatment plans based on radiobiological modeling.

  2. Intensity-modulated photon arc therapy for treatment of pleural mesothelioma

    International Nuclear Information System (INIS)

    Tobler, Matt; Watson, Gordon; Leavitt, Dennis

    2002-01-01

    Radiotherapy plays a key role in the definitive or adjuvant management of patients with mesothelioma of the pleural surface. Many patients are referred for radiation with intact lung following biopsy or subtotal pleurectomy. Delivery of efficacious doses of radiation to the pleural lining while avoiding lung parenchyma toxicity has been a difficult technical challenge. Using opposed photon fields produce doses in lung that result in moderate-to-severe pulmonary toxicity in 100% of patients treated. Combined photon-electron beam treatment, at total doses of 4250 cGy to the pleural surface, results in two-thirds of the lung volume receiving over 2100 cGy. We have developed a technique using intensity-modulated photon arc therapy (IMRT) that significantly improves the dose distribution to the pleural surface with concomitant decrease in dose to lung parenchyma compared to traditional techniques. IMRT treatment of the pleural lining consists of segments of photon arcs that can be intensity modulated with varying beam weights and multileaf positions to produce a more uniform distribution to the pleural surface, while at the same time reducing the overall dose to the lung itself. Computed tomography (CT) simulation is critical for precise identification of target volumes as well as critical normal structures (lung and heart). Rotational arc trajectories and individual leaf positions and weightings are then defined for each CT plane within the patient. This paper will describe the proposed rotational IMRT technique and, using simulated isodose distributions, show the improved potential for sparing of dose to the critical structures of the lung, heart, and spinal cord

  3. Comparison of a new noncoplanar intensity-modulated radiation therapy technique for craniospinal irradiation with 3 coplanar techniques

    DEFF Research Database (Denmark)

    Hansen, Anders T; Lukacova, Slavka; Lassen-Ramshad, Yasmin A.

    2015-01-01

    When standard conformal x-ray technique for craniospinal irradiation is used, it is a challenge to achieve satisfactory dose coverage of the target including the area of the cribriform plate, while sparing organs at risk. We present a new intensity-modulated radiation therapy (IMRT), noncoplanar...... patient using the noncoplanar IMRT-based technique, a coplanar IMRT-based technique, and a coplanar volumetric-modulated arch therapy (VMAT) technique. Dosimetry data for all patients were compared with the corresponding data from the conventional treatment plans. The new noncoplanar IMRT technique...... substantially reduced the mean dose to organs at risk compared with the standard radiation technique. The 2 other coplanar techniques also reduced the mean dose to some of the critical organs. However, this reduction was not as substantial as the reduction obtained by the noncoplanar technique. Furthermore...

  4. Unilateral and bilateral neck SIB for head and neck cancer patients. Intensity-modulated proton therapy, tomotherapy, and RapidArc

    Energy Technology Data Exchange (ETDEWEB)

    Stromberger, Carmen; Budach, Volker; Ghadjar, Pirus; Wlodarczyk, Waldemar; Marnitz, Simone [Charite - Universitaetsmedizin Berlin, Department of Radiation Oncology and Radiotherapy, Berlin (Germany); Cozzi, Luca; Fogliata, Antonella [Humanitas Cancer Center Milan, Radiotherapy and Radiosurgery Department, Milan (Italy); Jamil, Basil [Klinikum Frankfurt Oder, Praxis fuer Strahlentherapie, Frankfurt Oder (Germany); Raguse, Jan D. [Clinic for Oral and Maxillofacial Surgery, Berlin (Germany); Boettcher, Arne [Charite - Universitaetsmedizin Berlin, Department of Otorhinolaryngology, Berlin (Germany)

    2016-04-15

    To compare simultaneous integrated boost plans for intensity-modulated proton therapy (IMPT), helical tomotherapy (HT), and RapidArc therapy (RA) for patients with head and neck cancer. A total of 20 patients with squamous cell carcinoma of the head and neck received definitive chemoradiation with bilateral (n = 14) or unilateral (n = 6) neck irradiation and were planned using IMPT, HT, and RA with 54.4, 60.8, and 70.4 GyE/Gy in 32 fractions. Dose distributions, coverage, conformity, homogeneity to planning target volumes (PTV)s and sparing of organs at risk and normal tissue were compared. All unilateral and bilateral plans showed excellent PTV coverage and acceptable dose conformity. For unilateral treatment, IMPT delivered substantially lower mean doses to contralateral salivary glands (< 0.001-1.1 Gy) than both rotational techniques did (parotid gland: 6-10 Gy; submandibular gland: 15-20 Gy). Regarding the sparing of classical organs at risk for bilateral treatment, IMPT and HT were similarly excellent and RA was satisfactory. For unilateral neck irradiation, IMPT may minimize the dry mouth risk in this subgroup but showed no advantage over HT for bilateral neck treatment regarding classical organ-at-risk sparing. All methods satisfied modern standards regarding toxicity and excellent target coverage for unilateral and bilateral treatment of head and neck cancer at the planning level. (orig.) [German] Planvergleich von intensitaetsmodulierter Protonentherapie (IMPT), Tomotherapie (HT) und RapidArc-Therapie (RA) fuer Patienten mit Plattenepithelkarzinomen der Kopf-Hals-Region unter Anwendung des simultan integrierten Boost-Konzepts (SIB). Fuer 20 Patienten mit Plattenepithelkarzinomen der Kopf-Hals-Region und bilateraler (n = 14) oder unilateraler (n = 6) zervikaler primaerer Radiochemotherapie erfolgte eine IMPT-, HT- und RA-Planung mit 54,4, 60,8 und 70,4 GyE/Gy in 32 Fraktionen. Die Dosisverteilung, Abdeckung, Konformitaet und Homogenitaet der PTVs sowie die

  5. Single-energy intensity modulated proton therapy

    Science.gov (United States)

    Farace, Paolo; Righetto, Roberto; Cianchetti, Marco

    2015-09-01

    In this note, an intensity modulated proton therapy (IMPT) technique, based on the use of high single-energy (SE-IMPT) pencil beams, is described. The method uses only the highest system energy (226 MeV) and only lateral penumbra to produce dose gradient, as in photon therapy. In the study, after a preliminary analysis of the width of proton pencil beam penumbras at different depths, SE-IMPT was compared with conventional IMPT in a phantom containing titanium inserts and in a patient, affected by a spinal chordoma with fixation rods. It was shown that SE-IMPT has the potential to produce a sharp dose gradient and that it is not affected by the uncertainties produced by metal implants crossed by the proton beams. Moreover, in the chordoma patient, target coverage and organ at risk sparing of the SE-IMPT plan resulted comparable to that of the less reliable conventional IMPT technique. Robustness analysis confirmed that SE-IMPT was not affected by range errors, which can drastically affect the IMPT plan. When accepting a low-dose spread as in modern photon techniques, SE-IMPT could be an option for the treatment of lesions (e.g. cervical bone tumours) where steep dose gradient could improve curability, and where range uncertainty, due for example to the presence of metal implants, hampers conventional IMPT.

  6. Single-energy intensity modulated proton therapy.

    Science.gov (United States)

    Farace, Paolo; Righetto, Roberto; Cianchetti, Marco

    2015-10-07

    In this note, an intensity modulated proton therapy (IMPT) technique, based on the use of high single-energy (SE-IMPT) pencil beams, is described.The method uses only the highest system energy (226 MeV) and only lateral penumbra to produce dose gradient, as in photon therapy. In the study, after a preliminary analysis of the width of proton pencil beam penumbras at different depths, SE-IMPT was compared with conventional IMPT in a phantom containing titanium inserts and in a patient, affected by a spinal chordoma with fixation rods.It was shown that SE-IMPT has the potential to produce a sharp dose gradient and that it is not affected by the uncertainties produced by metal implants crossed by the proton beams. Moreover, in the chordoma patient, target coverage and organ at risk sparing of the SE-IMPT plan resulted comparable to that of the less reliable conventional IMPT technique. Robustness analysis confirmed that SE-IMPT was not affected by range errors, which can drastically affect the IMPT plan.When accepting a low-dose spread as in modern photon techniques, SE-IMPT could be an option for the treatment of lesions (e.g. cervical bone tumours) where steep dose gradient could improve curability, and where range uncertainty, due for example to the presence of metal implants, hampers conventional IMPT.

  7. Single-energy intensity modulated proton therapy

    International Nuclear Information System (INIS)

    Farace, Paolo; Righetto, Roberto; Cianchetti, Marco

    2015-01-01

    In this note, an intensity modulated proton therapy (IMPT) technique, based on the use of high single-energy (SE-IMPT) pencil beams, is described.The method uses only the highest system energy (226 MeV) and only lateral penumbra to produce dose gradient, as in photon therapy. In the study, after a preliminary analysis of the width of proton pencil beam penumbras at different depths, SE-IMPT was compared with conventional IMPT in a phantom containing titanium inserts and in a patient, affected by a spinal chordoma with fixation rods.It was shown that SE-IMPT has the potential to produce a sharp dose gradient and that it is not affected by the uncertainties produced by metal implants crossed by the proton beams. Moreover, in the chordoma patient, target coverage and organ at risk sparing of the SE-IMPT plan resulted comparable to that of the less reliable conventional IMPT technique. Robustness analysis confirmed that SE-IMPT was not affected by range errors, which can drastically affect the IMPT plan.When accepting a low-dose spread as in modern photon techniques, SE-IMPT could be an option for the treatment of lesions (e.g. cervical bone tumours) where steep dose gradient could improve curability, and where range uncertainty, due for example to the presence of metal implants, hampers conventional IMPT. (note)

  8. CT evaluation of mass lesions in the parotid region

    International Nuclear Information System (INIS)

    Matsumoto, Shunichi; Kishikawa, Takashi; Kudo, Sho; Miyaji, Hiroshi; Kuwano, Haruo; Kaneko, Kuniyuki; Ohuchida, Toshiyuki

    1988-01-01

    CT findings of 35 patients with proven 31 parotid gland mass lesions (23 benign tumors, 5 malignant tumors, 3 inflammatory diseases) and 4 infraauricular lymphadenopathy (2 inflammatory nodes, 2 neoplastic nodes) were reviewed. CT accurately diagnosed the parotid origin in 29 of 31 parotid gland diseases. In all four patients with infraauricular lymphadenopathy, differentiation from parotid tumor was difficult. CT differentiation between superficial and deep lobe tumors agreed with surgical findings in 18 of 21 parotid gland tumors. Twenty out of 23 benign parotid gland tumors appeared as discrete masses with smooth margins. All five malignant parotid gland tumors appeared as poorly defined masses. It is concluded that when a tumor is located in the superficial lobe and appears as a sharply circumscribed mass on plain CT, it should be diagnosed as a benign lesion and contrast CT is not required. Secondly, contrast CT would be beneficial when a tumor is indistinct, or located in the deep portion of the parotid gland on plain CT. Finally, CT-sialography is considered unnecessary in the diagnosis of parotid masses. (author)

  9. Intensity modulated radiotherapy for elderly bladder cancer patients

    Directory of Open Access Journals (Sweden)

    Chong Ngot-Swan

    2011-06-01

    Full Text Available Abstract Background To review our experience and evaluate treatment planning using intensity-modulated radiotherapy (IMRT and helical tomotherapy (HT for the treatment of elderly patients with bladder cancer. Methods From November 2006 through November 2009, we enrolled 19 elderly patients with histologically confirmed bladder cancer, 9 in the IMRT and 10 in the HT group. The patients received 64.8 Gy to the bladder with or without concurrent chemotherapy. Conventional 4-field "box" pelvic radiation therapy (2DRT plans were generated for comparison. Results The median patient age was 80 years old (range, 65-90 years old. The median survival was 21 months (5 to 26 months. The actuarial 2-year overall survival (OS for the IMRT vs. the HT group was 26.3% vs .37.5%, respectively; the corresponding values for disease-free survival were 58.3% vs. 83.3%, respectively; for locoregional progression-free survival (LRPFS, the values were 87.5% vs. 83.3%, respectively; and for metastases-free survival, the values were 66.7% vs. 60.0%, respectively. The 2-year OS rates for T1, 2 vs. T3, 4 were 66.7% vs. 35.4%, respectively (p = 0.046. The 2-year OS rate was poor for those whose RT completion time greater than 8 weeks when compared with the RT completed within 8 wks (37.9% vs. 0%, p = 0.004. Conclusion IMRT and HT provide good LRPFS with tolerable toxicity for elderly patients with invasive bladder cancer. IMRT and HT dosimetry and organ sparing capability were superior to that of 2DRT, and HT provides better sparing ability than IMRT. The T category and the RT completion time influence OS rate.

  10. The role of parotid gland irradiation in the development of severe hyposalivation (xerostomia) after intensity-modulated radiation therapy for head and neck cancer: Temporal patterns, risk factors, and testing the QUANTEC guidelines.

    Science.gov (United States)

    Owosho, Adepitan A; Thor, Maria; Oh, Jung Hun; Riaz, Nadeem; Tsai, C Jillian; Rosenberg, Haley; Varthis, Spyridon; Yom, Sae Hee K; Huryn, Joseph M; Lee, Nancy Y; Deasy, Joseph O; Estilo, Cherry L

    2017-04-01

    The aims of this study were to investigate temporal patterns and potential risk factors for severe hyposalivation (xerostomia) after intensity-modulated radiotherapy (IMRT) for head and neck cancer (HNC), and to test the two QUANTEC (Quantitative Analysis of Normal Tissue Effects in the Clinic) guidelines. Sixty-three patients treated at the Memorial Sloan Kettering Cancer Center between 2006 and 2015, who had a minimum of three stimulated whole mouth saliva flow measurements (WMSFM) at a median follow-up time of 11 (range: 3-24) months were included. Xerostomia was defined as WMSFM ≤25% compared to relative pre-radiotherapy. Patients were stratified into three follow-up groups: 1: xerostomia was 27%, 14% and 17% at follow-up time points 1, 2 and 3, respectively. At xerostomia (Dmean contra : 25 Gy vs. 15 Gy; Dmean ipsi : 44 Gy vs. 25 Gy). Patients with xerostomia had higher pre-RT WMSFM (3.5 g vs. 2.4 g), and had been treated more frequently with additional chemotherapy (93% vs. 63%; all 4 variables: p xerostomia was higher compared to patients without (26 Gy vs. 20 Gy). The RR as specified by the one- and two-gland QUANTEC guideline was 2.3 and 1.4 for patients with Xerostomia following IMRT peaks within six months post-radiotherapy and fades with time. Limiting the mean dose to both parotid glands (ipsilateral xerostomia. Both QUANTEC guidelines are effective in preventing xerostomia. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  11. A dosimetric comparison of two-phase adaptive intensity-modulated radiotherapy for locally advanced nasopharyngeal cancer

    International Nuclear Information System (INIS)

    Chitapanarux, Imjai; Chomprasert, Kittisak; Nobnaop, Wannapa; Wanwilairat, Somsak; Tharavichitkul, Ekasit; Jakrabhandu, Somvilai; Onchan, Wimrak; Patrinee, Traisathit; Gestel, Dirk Van

    2015-01-01

    The purpose of this investigation was to evaluate the potential dosimetric benefits of a two-phase adaptive intensity-modulated radiotherapy (IMRT) protocol for patients with locally advanced nasopharyngeal cancer (NPC). A total of 17 patients with locally advanced NPC treated with IMRT had a second computed tomography (CT) scan after 17 fractions in order to apply and continue the treatment with an adapted plan after 20 fractions. To simulate the situation without adaptation, a hybrid plan was generated by applying the optimization parameters of the original treatment plan to the anatomy of the second CT scan. The dose-volume histograms (DVHs) and dose statistics of the hybrid plan and the adapted plan were compared. The mean volume of the ipsilateral and contralateral parotid gland decreased by 6.1 cm 3 (30.5%) and 5.4 cm 3 (24.3%), respectively. Compared with the hybrid plan, the adapted plan provided a higher dose to the target volumes with better homogeneity, and a lower dose to the organs at risk (OARs). The Dmin of all planning target volumes (PTVs) increased. The Dmax of the spinal cord and brainstem were lower in 94% of the patients (1.6-5.9 Gy, P < 0.001 and 2.1-9.9 Gy, P < 0.001, respectively). The D mean of the contralateral parotid decreased in 70% of the patients (range, 0.2-4.4 Gy). We could not find a relationship between dose variability and weight loss. Our two-phase adaptive IMRT protocol improves dosimetric results in terms of target volumes and OARs in patients with locally advanced NPC. (author)

  12. Is there room for combined modality treatments? Dosimetric comparison of boost strategies for advanced head and neck and prostate cancer

    International Nuclear Information System (INIS)

    Gora, Joanna; Hopfgartner, Johannes; Kuess, Peter; Paskeviciute, Brigita; Georg, Dietmar

    2013-01-01

    The purpose of the study was to determine the dosimetric difference between three emerging treatment modalities-volumetric-modulated arc therapy (VMAT), intensity-modulated proton beam therapy (IMPT) and intensity-modulated carbon ion beam therapy (IMIT)-for two tumour sites where selective boosting of the tumour is applied. For 10 patients with locally advanced head and neck (H and N) cancer and 10 with high-risk prostate cancer (PC) a VMAT plan was generated for PTV initial that included lymph node regions, delivering 50 Gy (IsoE) for H and N and 50.4 Gy (IsoE) for PC patients. Furthermore, separate boost plans (VMAT, IMPT and IMIT) were created to boost PTV boost up to 70 Gy (IsoE) and 78 Gy (IsoE) for H and N and PC cases, respectively. Doses to brainstem, myelon, larynx and parotid glands were assessed for H and N cases. Additionally, various organs at risk (OARs) (e.g. cochlea, middle ear, masticator space) were evaluated that are currently discussed with respect to quality of life after treatment. For PC cases, bladder, rectum and femoral heads were considered as OARs. For both tumour sites target goals were easily met. Looking at OAR sparing, generally VMAT + VMAT was worst. VMAT + IMIT had the potential to spare some structures in very close target vicinity (such as cochlea, middle ear, masticator space) significantly better than VMAT + IMPT. Mean doses for rectal and bladder wall were on average 4 Gy (IsoE) and 1.5 Gy (IsoE) higher, respectively, compared to photons plus particles scenarios. Similar results were found for parotid glands and larynx. Concerning target coverage, no significant differences were observed between the three treatment concepts. Clear dosimetric benefits were observed for particle beam therapy as boost modality. However, the clinical benefit of combined modality treatments remains to be demonstrated. (author)

  13. RADIATION THERAPY COMMUNICATION-REIRRADIATION OF A NASAL TUMOR IN A BRACHYCEPHALIC DOG USING INTENSITY MODULATED RADIATION THERAPY.

    Science.gov (United States)

    Rancilio, Nicholas J; Custead, Michelle R; Poulson, Jean M

    2016-09-01

    A 5-year-old spayed female Shih Tzu was referred for evaluation of a nasal transitional carcinoma. A total lifetime dose of 117 Gy was delivered to the intranasal mass in three courses over nearly 2 years using fractionated intensity modulated radiation therapy (IMRT) to spare normal tissues. Clinically significant late normal tissue side effects were limited to bilaterally diminished tear production. The patient died of metastatic disease progression 694 days after completion of radiation therapy course 1. This case demonstrates that retreatment with radiation therapy to high lifetime doses for recurrent local disease may be well tolerated with IMRT. © 2016 American College of Veterinary Radiology.

  14. Dosimetric comparison between intensity modulated brachytherapy versus external beam intensity modulated radiotherapy for cervix cancer: a treatment planning study

    International Nuclear Information System (INIS)

    Subramani, V.; Sharma, D.N.; Jothy Basu, K.S.; Rath, G.K.; Gopishankar, N.

    2008-01-01

    To evaluate the dosimetric superiority of intensity modulated brachytherapy (IMBT) based on inverse planning optimization technique with classical brachytherapy optimization and also with external beam intensity modulated radiotherapy planning technique in patients of cervical carcinoma

  15. Is parotid saliva sterile on entry to the oral cavity?

    DEFF Research Database (Denmark)

    Schrøder, Stine A; Bardow, Allan; Eickhardt-Dalbøge, Steffen

    2017-01-01

    CONCLUSION: The present study indicates that parotid saliva is sterile on entry to the oral cavity. OBJECTIVES: The objective was to investigate if parotid saliva is sterile on entry to the oral cavity and, thus, prior to contamination by oral bacteria. METHOD: Forty healthy volunteers were...... included in sterile parotid saliva collection. Parotid saliva was collected using a sterile Lashley cup, placed over the papilla of the Stensen´s duct, as well as sterile tubes and syringes for collection. All collections were followed by collection of a positive control sample where some of the sterile...... obtained parotid saliva had been exposed to the contralateral mucosal membranes. All samples parotid saliva, as well as the positive controls, were cultivated, and 10 randomly selected parotid saliva samples underwent polymerase chain reaction (PCR) analyses. RESULTS: In 33 of 40 parotid saliva samples...

  16. Unilateral multiple tumorous lesions of the parotid gland

    International Nuclear Information System (INIS)

    Takahashi, Mitsuaki; Fujita, Takenori; Adachi, Tosihide; Enomoto, Kenichi; Ishii, Hidenori; Yoshida, Chikako; Hokunan, Kazuhiko; Bando, Nobuyuki; Shigyo, Hiroshi.

    1997-01-01

    Multifocal tumors within the same parotid gland are very rare. We treated 13 patients with multiple tumorous lesions within the unilateral parotid gland. We evaluated the multiple nodules by CT-sialography or magnetic resonance imaging (MRI). These imagings showed clearly two or more distinct nodular-appearing lesions. Recurrent pleomorphic adenoma (6 patients) was predominant, followed by Whartin's tumor (3 patients). The other lesions were two differential parenchymal tumors (polymorphous low grade adenoma/adenoma) within the same gland, a malignant lymphoma, a squamous cell carcinoma metastatic to the gland, and a tuberculous lesion. On palpitation, 9 of the patients had an unilateral tumor, one a palpable parotid mass in the gland, and the other four had two or more tumors in the unilateral gland. The patients with intra-parotid lymph node and metastatic lesions had extra-parotid cervical adenopathy. The clinical features and the differential diagnosis of the unilateral multiple tumors lesions of the parotid gland are discussed. (author)

  17. Randomized phase II trial of urethral sparing intensity modulated radiation therapy in low-risk prostate cancer: implications for focal therapy

    International Nuclear Information System (INIS)

    Vainshtein, Jeffrey; Hamstra, Daniel A; Abu-Isa, Eyad; Olson, Karin B; Ray, Michael E; Sandler, Howard M; Normolle, Dan; Litzenberg, Dale W; Masi, Kathryn; Pan, Charlie

    2012-01-01

    Low-risk prostate cancer (PCa) patients have excellent outcomes, with treatment modality often selected by perceived effects on quality of life. Acute urinary symptoms are common during external beam radiotherapy (EBRT), while chronic symptoms have been linked to urethral dose. Since most low-risk PCa occurs in the peripheral zone (PZ), we hypothesized that EBRT using urethral sparing intensity modulated radiation therapy (US-IMRT) could improve urinary health-related quality of life (HRQOL) while maintaining high rates of PCa control. Patients with National Comprehensive Cancer Network (NCCN) defined low-risk PCa with no visible lesion within 5 mm of the prostatic urethra on MRI were randomized to US-IMRT or standard (S-) IMRT. Prescription dose was 75.6 Gy in 41 fractions to the PZ + 3–5 mm for US-IMRT and to the prostate + 3 mm for S-IMRT. For US-IMRT, mean proximal and distal urethral doses were limited to 65 Gy and 74 Gy, respectively. HRQOL was assessed using the Expanded Prostate Cancer Index (EPIC) Quality of Life questionnaire. The primary endpoint was change in urinary HRQOL at 3 months. From June 2004 to November 2006, 16 patients were randomized, after which a futility analysis concluded that continued accrual was unlikely to demonstrate a difference in the primary endpoint. Mean change in EPIC urinary HRQOL at 3 months was −0.5 ± 11.2 in the US-IMRT arm and +3.9 ± 15.3 in the S-IMRT arm (p = 0.52). Median PSA nadir was higher in the US-IMRT arm (1.46 vs. 0.78, p = 0.05). At 4.7 years median follow-up, three US-IMRT and no S-IMRT patients experienced PSA failure (p = 0.06; HR 8.8, 95% CI 0.9–86). Two out of 3 patients with PSA failure had biopsy-proven local failure, both located contralateral to the original site of disease. Compared with S-IMRT, US-IMRT failed to improve urinary HRQOL and resulted in higher PSA nadir and inferior biochemical control. The high rate of PSA failure and contralateral local failures in US-IMRT patients, despite

  18. Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pokhrel, Damodar, E-mail: dpokhrel@kumc.edu; Sood, Sumit; McClinton, Christopher; Shen, Xinglei; Lominska, Christopher; Saleh, Habeeb; Badkul, Rajeev; Jiang, Hongyu; Mitchell, Melissa; Wang, Fen

    2016-01-01

    Purpose: To retrospectively evaluate the accuracy, plan quality and efficiency of intensity-modulated arc therapy (IMAT) for hippocampal sparing whole-brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in patients with multiple brain metastases (m-BM). Materials and methods: A total of 5 patients with m-BM were retrospectively replanned for HS-WBRT with SIB using IMAT treatment planning. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been fused with the planning CT image set. The hippocampal avoidance zone (HAZ) was generated using a 5-mm uniform margin around the paired hippocampi. The m-BM planning target volumes (PTVs) were contoured on T1/T2-weighted MRI registered with the 3D planning computed tomography (CT). The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume minus HAZ and m-BM PTVs. Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis-TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5-mm leaf width at isocenter) and 6-MV beam. Prescription dose was 30 Gy for WB-PTV and 45 Gy for each m-BM in 10 fractions. Three full coplanar arcs with orbit avoidance sectors were used. Treatment plans were evaluated using homogeneity (HI) and conformity indices (CI) for target coverage and dose to organs at risk (OAR). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance (QA) with a MapCHECK device. Actual beam-on time was recorded and a gamma index was used to compare dose agreement between the planned and measured doses. Results: All 5 HS-WBRT with SIB plans met WB-PTV D{sub 2%}, D{sub 98%}, and V{sub 30} {sub Gy} NRG-CC001 requirements. The plans demonstrated highly conformal and homogenous coverage of the WB-PTV with mean HI and CI values of 0.33 ± 0.04 (range: 0.27 to 0.36), and 0.96 ± 0.01 (range: 0.95 to 0.97), respectively. All 5

  19. Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy

    International Nuclear Information System (INIS)

    Pokhrel, Damodar; Sood, Sumit; McClinton, Christopher; Shen, Xinglei; Lominska, Christopher; Saleh, Habeeb; Badkul, Rajeev; Jiang, Hongyu; Mitchell, Melissa; Wang, Fen

    2016-01-01

    Purpose: To retrospectively evaluate the accuracy, plan quality and efficiency of intensity-modulated arc therapy (IMAT) for hippocampal sparing whole-brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in patients with multiple brain metastases (m-BM). Materials and methods: A total of 5 patients with m-BM were retrospectively replanned for HS-WBRT with SIB using IMAT treatment planning. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been fused with the planning CT image set. The hippocampal avoidance zone (HAZ) was generated using a 5-mm uniform margin around the paired hippocampi. The m-BM planning target volumes (PTVs) were contoured on T1/T2-weighted MRI registered with the 3D planning computed tomography (CT). The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume minus HAZ and m-BM PTVs. Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis-TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5-mm leaf width at isocenter) and 6-MV beam. Prescription dose was 30 Gy for WB-PTV and 45 Gy for each m-BM in 10 fractions. Three full coplanar arcs with orbit avoidance sectors were used. Treatment plans were evaluated using homogeneity (HI) and conformity indices (CI) for target coverage and dose to organs at risk (OAR). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance (QA) with a MapCHECK device. Actual beam-on time was recorded and a gamma index was used to compare dose agreement between the planned and measured doses. Results: All 5 HS-WBRT with SIB plans met WB-PTV D 2% , D 98% , and V 30 Gy NRG-CC001 requirements. The plans demonstrated highly conformal and homogenous coverage of the WB-PTV with mean HI and CI values of 0.33 ± 0.04 (range: 0.27 to 0.36), and 0.96 ± 0.01 (range: 0.95 to 0.97), respectively. All 5 hippocampal sparing

  20. Impact of patient positioning on radiotherapy dose distribution: An assessment in parotid tumor

    Directory of Open Access Journals (Sweden)

    Seema Sharma

    2016-03-01

    Full Text Available Purpose: We intended to study the impact of patient positioning on the dose distribution within target volume and organs at risk in patients with parotid malignancies treated with 3D conformal radiotherapy (3D-CRT with photon wedge pair (WP or intensity modulated radiotherapy (IMRT.Methods: Three patients with a non-Hodgkin’s lymphoma of the right parotid gland were consecutively immobilized using thermoplastic cast in 2 positions: supine with head in neutral position (HN and with head turned 90° to the left side (HT. Images for treatment planning purpose were acquired in both positions. For both positions, photon WP plans and 5 field IMRT plans were generated, after contouring clinical target volume (CTV, planning target volume (PTV= CTV + 5 mm margin and organs at risk (OAR. All plans were evaluated for target coverage and dose to OARs.Results: Both CTV and PTV were apparently larger in HN compared with HT (31.76±8.89 cc, 30.31±7.83 cc and 62.49±19.01 cc, 58.89±15.33 cc respectively. The CI value for PTV was slightly better for HT compared to HN position in both the WP and IMRT plans. The homogeneity was comparable in both the head positions in case of WP plan. The mean HI of PTV was increased in case of IMRT plan at HT versus HN position (1.108 vs. 1.097. A change in head position from HN to HT with wedge pair plan resulted in a reduction of brainstem Dmax and Dmean. Lesser dose was observed in HN position for contralateral parotid. A difference of 0.9 Gy in the average Dmax to spinal cord was seen. The values of Dmean to mandible, oral cavity, ipsilateral and contralateral cochlea were higher in the HT position. A change in head position from HN to HT with IMRT plan resulted in a dose reduction in average Dmax to brainstem. The spinal cord Dmax increased at the HT position by 1.2 Gy. The dose to contralateral parotid and cochlea was comparable in both the positions. However, the Dmean to oral cavity was reduced at HT position. Whereas

  1. Dynamic intensity-modulated non-coplanar arc radiotherapy (INCA) for head and neck cancer

    International Nuclear Information System (INIS)

    Krayenbuehl, Jerome; Davis, J. Bernard; Ciernik, I. Frank

    2006-01-01

    Background and purpose: To define the potential advantages of intensity-modulated radiotherapy (IMRT) applied using a non-coplanar dynamic arc technique for the treatment of head and neck cancer. Materials and methods: External beam radiotherapy (EBRT) was planned in ten patients with head and neck cancer using coplanar IMRT and non-coplanar arc techniques, termed intensity modulated non-coplanar arc EBRT (INCA). Planning target volumes (PTV1) of first order covered the gross tumor volume and surrounding clinical target volume treated with 68-70 Gy, whereas PTV2 covered the elective lymph nodes with 54-55 Gy using a simultaneous internal boost. Treatment plan comparison between IMRT and INCA was carried out using dose-volume histogram and 'equivalent uniform dose' (EUD). Results: INCA resulted in better dose coverage and homogeneity of the PTV1, PTV2, and reduced dose delivered to most of the organs at risk (OAR). For the parotid glands, a reduction of the mean dose of 2.9 (±2.0) Gy was observed (p 0.002), the mean dose to the larynx was reduced by 6.9 (±2.9) Gy (p 0.003), the oral mucosa by 2.4 (±1.1) Gy (p < 0.001), and the maximal dose to the spinal cord by 3.2 (±1.7) Gy (p = 0.004). The mean dose to the brain was increased by 3.0 (±1.4) Gy (p = 0.002) and the mean lung dose increased by 0.2 (±0.4) Gy (p = 0.87). The EUD suggested better avoidance of the OAR, except for the lung, and better coverage and dose uniformity were achieved with INCA compared to IMRT. Conclusion: Dose delivery accuracy with IMRT using a non-coplanar dynamic arc beam geometry potentially improves treatment of head and neck cancer

  2. Regional radiation dose susceptibility within the parotid gland: Effects on salivary loss and recovery

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Haley, E-mail: hdclark@phas.ubc.ca; Reinsberg, Stefan [Department of Physics and Astronomy, University of British Columbia, Vancouver, British Columbia V6T 1Z1 (Canada); Hovan, Allan [Oral Oncology/Dentistry, British Columbia Cancer Agency–Vancouver Centre, Vancouver, British Columbia V5Z 4E6 (Canada); Moiseenko, Vitali [Department of Radiation Medicine and Applied Sciences, University of California–San Diego, La Jolla, California 92093 (United States); Thomas, Steven [Department of Medical Physics, British Columbia Cancer Agency–Vancouver Centre, Vancouver, British Columbia V5Z 4E6 (Canada); Wu, Jonn [Radiation Oncology, British Columbia Cancer Agency–Vancouver Centre, Vancouver, British Columbia V5Z 4E6 (Canada)

    2015-04-15

    Purpose: Xerostomia is one of the most likely late toxic effects of radiotherapy treatment in patients with head-and-neck cancers. Modern treatment techniques can incorporate knowledge of complication risk into treatment plans. To this end, the authors attempt to quantify the regional radiotherapy dose-dependence of salivary output loss and recovery in a prospective study. Methods: Salivary output was collected from patients undergoing radiotherapy treatment for head-and-neck cancers at the BC Cancer Agency between February 2008 and May 2013. Regional dose-dependence (i.e., dose susceptibility) of loss and recovery is quantified using nonparametric (Spearman’s rank correlation coefficients, local linear regression) and parametric (least-sum of squares, least-median of squares) techniques. Results: Salivary flow recovery was seen in 79 of 102 patients considered (p < 0.0001, Wilcoxon sign rank test). Output loss was strongly correlated with left- and right parotid combined dose φ = min (D{sub L},  45 Gy) + min (D{sub R},  45 Gy), and can be accurately predicted. Median early loss (three months) was 72% of baseline, while median overall loss (1 yr) was 56% of baseline. Fitting an exponential model to whole parotid yields dose sensitivities A{sub 3m} = 0.0604 Gy{sup −1} and A{sub 1y} = 0.0379 Gy{sup −1}. Recovery was not significantly associated with dose. Hints of lateral organ sub-segment dose–response dimorphism were observed. Conclusions: Sub-segmentation appears to predict neither loss nor recovery with any greater precision than whole parotid mean dose, though it is not any worse. Sparing the parotid to a combined dose φ of <50 Gy is recommended for a patient to keep ≈40% of baseline function and thus avoid severe xerostomia at 12 months post-treatment. It seems unlikely that a population’s mean recovery will exceed 20%–30% of baseline output at 1 yr after radiotherapy treatment using current (whole-organ based) clinical guidelines.

  3. VACCINATION OF CHILDREN AGAINST MEASLES, PAROTIDITIS AND VITAMINOTHERAPY

    OpenAIRE

    S.M. Kharit; T.V. Chernyaeva; E.P. Nacharova; O.V. Goleva

    2007-01-01

    The researchers observed 45 children inoculated with the Russian divalent vaccine (measles–parotiditis). 25 children received mineral and vitamin complex «jungle» for a month since the date of vaccination. The application of «jungle» medication was efficient and conduced to prophylaxis of the complication of the vaccination, prevention of the inter current diseases among the vaccinated, as well as positively affected the intensity of the special antibody formation because of activation of cel...

  4. Bilateral parotid gland tuberculosis: A rare occurrence

    Directory of Open Access Journals (Sweden)

    Rajendra Takhar

    2015-07-01

    Full Text Available Parotid gland tuberculosis is an extremely rare form of extrapulmonary tuberculosis, even in countries where tuberculosis is endemic like India; however, it should be included as one of the differentials of discrete parotid swelling as it generally presents as a slow-growing mass indistinguishable from a malignancy and even imaging too, can’t differentiate these clearly. The majority of the previously reported cases were mostly unilateral and diagnosed by histopathological examination of post parotidectomy specimens. Here we are describing a case of tuberculosis of both parotid glands in a 25 year-old male who was referred to us with bilateral parotid region swelling of two month duration. Tubercular parotiditis was confirmed by demonstration of epithelioid granuloma and caseous necrosis compatible with TB on fine needle aspiration cytology (FNAC. He was treated with four drug anti-TB regimen (2HERZ + 4HR leading to full recovery and complete disappearance of swelling and symptoms with no recurrence till one year of follow up. Apart from rarity due to bilateral involvement, this case report highlights the clinical presentation, ultrasonography and other imaging findings, and significance of FNAC in diagnosis of this uncommon entity reinforcing the fact that the diagnosis of parotid gland tuberculosis requires a high degree of clinical suspicion.

  5. Acute parotiditis after cesarean section; case report

    Directory of Open Access Journals (Sweden)

    Cristina Moisei

    2017-11-01

    Full Text Available The enlargement of the parotid gland develops in inflammatory or stenotic conditions but after Cesarean section the symptomatology is unusual. A 38 year old patient with no obstetrical history referred to our clinic for pregnancy, which followed our national program of prenatal care. The outcome of the pregnancy was favorable for both mother and fetus. During labor the fetus developed bradycardia and the patient delivered by Cesarean section a 3400 g baby-boy with 8 Apgar Score; the anesthesia was spinal. 18 hours after delivery the patient presented mild respiratory distress. The symptomatology was caused by the enlargement of the parotid gland. The treatment was supportive and the remission occurred 10 hours after the onset. The initial discussion that raised this case was caused by the viral, infection and stenotic cause of the parotiditis. All these reasons had no medical argument. It was also debated about the anesthesia but, until now, the medical literature didn’t report any case of association between parotiditis and spinal anesthesia. It is also impossible to correlate the parotiditis with IVF procedure. As a conclusion, this case is unique because it represents the parotiditis without unknown case that appeared after Cesarean section and spinal anesthesia in a healthy woman.

  6. Parotid salivary duct stenosis following caudal maxillectomy.

    Science.gov (United States)

    Mestrinho, Lisa A; Faísca, Pedro B; Niza, Maria M R E

    2014-01-01

    Parotid salivary duct dilation was diagnosed in a 9-year-old male dog. The dog had undergone caudal maxillectomy on the ipsilateral side 2-years prior to presentation. Treatment consisted of parotid salivary duct excision and superficial parotidectomy that lead to the resolution of clinical signs. Transient facial neuropraxia was observed immediately after surgery and resolved spontaneously after 2-weeks. Parotid salivary duct dilation should be considered as a chronic postoperative complication following caudal maxillectomy.

  7. Weekly Volume and Dosimetric Changes During Chemoradiotherapy With Intensity-Modulated Radiation Therapy for Head and Neck Cancer: A Prospective Observational Study

    Energy Technology Data Exchange (ETDEWEB)

    Bhide, Shreerang A [Institute of Cancer Research, 237 Fulham Road, London SW6 6JB (United Kingdom); Head and Neck Unit, Royal Marsden NHS Foundation Trust Hospital, London SW3 6JJ (United Kingdom); Davies, Mark; Burke, Kevin; McNair, Helen A; Hansen, Vibeke [Department of Radiation Oncology, Royal Marsden NHS Foundation Trust Hospital, London and Sutton (United Kingdom); Barbachano, Y [Department of Statistics, Royal Marsden NHS Foundation Trust Hospital, London and Sutton (United Kingdom); El-Hariry, I A [Head and Neck Unit, Royal Marsden NHS Foundation Trust Hospital, London SW3 6JJ (United Kingdom); Newbold, Kate [Department of Radiation Oncology, Royal Marsden NHS Foundation Trust Hospital, London and Sutton (United Kingdom); Harrington, Kevin J [Institute of Cancer Research, 237 Fulham Road, London SW6 6JB (United Kingdom); Head and Neck Unit, Royal Marsden NHS Foundation Trust Hospital, London SW3 6JJ (United Kingdom); Nutting, Christopher M., E-mail: chris.nutting@rmh.nhs.u [Head and Neck Unit, Royal Marsden NHS Foundation Trust Hospital, London SW3 6JJ (United Kingdom)

    2010-04-15

    Purpose: The aim of this study was to investigate prospectively the weekly volume changes in the target volumes and organs at risk and the resulting dosimetric changes during induction chemotherapy followed by chemoradiotherapy with intensity-modulated radiation therapy (C-IMRT) for head-and-neck cancer patients. Methods and Materials: Patients receiving C-IMRT for head-and-neck cancer had repeat CT scans at weeks 2, 3, 4, and 5 during radiotherapy. The volume changes of clinical target volume 1 (CTV1) and CTV2 and the resulting dosimetric changes to planning target volume 1 (PTV1) and PTV2 and the organs at risk were measured. Results: The most significant volume differences were seen at week 2 for CTV1 and CTV2. The reductions in the volumes of CTV1 and CTV2 at week 2 were 3.2% and 10%, respectively (p = 0.003 and p < 0.001). The volume changes resulted in a significant reduction in the minimum dose to PTV1 and PTV2 (2 Gy, p = 0.002, and 3.9 Gy, p = 0.03, respectively) and an increased dose range across PTV1 and PTV2 (2.5 Gy, p < 0.001, and 5.1 Gy, p = 0.008, respectively). There was a 15% reduction in the parotid volumes by week 2 (p < 0.001) and 31% by week 4 (p < 0.001). There was a statistically significant increase in the mean dose to the ipsilateral parotid only at week 4 (2.7 Gy, p = 0.006). The parotid glands shifted medially by an average of 2.3 mm (p < 0.001) by week 4. Conclusion: The most significant volumetric changes and dosimetric alterations in the tumor volumes and organs at risk during a course of C-IMRT occur by week 2 of radiotherapy. Further adaptive radiotherapy with replanning, if appropriate, is recommended.

  8. Whole-brain Irradiation Field Design: A Comparison of Parotid Dose

    International Nuclear Information System (INIS)

    Wu, Cheng-Chia; Wuu, Yen-Ruh; Jani, Ashish; Saraf, Anurag; Tai, Cheng-Hung; Lapa, Matthew E.; Andrew, Jacquelyn I.S.; Tiwari, Akhil; Saadatmand, Heva J.; Isaacson, Steven R.; Cheng, Simon K.; Wang, Tony J.C.

    2017-01-01

    Whole-brain radiation therapy (WBRT) plays an important role in patients with diffusely metastatic intracranial disease. Whether the extent of the radiation field design to C1 or C2 affects parotid dose and risk for developing xerostomia is unknown. The goal of this study is to examine the parotid dose based off of the inferior extent of WBRT field to either C1 or C2. Patients treated with WBRT with either 30 Gy or 37.5 Gy from 2011 to 2014 at a single institution were examined. Parotid dose constraints were compared with Radiation Therapy Oncology Group (RTOG) 0615 nasopharyngeal carcinoma for a 33-fraction treatment: mean <26 Gy, volume constraint at 20 Gy (V20) < 20 cc, and dose at 50% of the parotid volume (D50) < 30 Gy. Biologically effective dose (BED) conversions with an α/β of 3 for normal parotid were performed to compare with 10-fraction and 15-fraction treatments of WBRT. The constraints are as follows: mean < BED 32.83 Gy, V15.76 (for 10-fraction WBRT) or V17.35 (for 15-fraction WBRT) < 20 cc, and D50 < BED 39.09 Gy. Nineteen patients treated to C1 and 26 patients treated to C2 were analyzed. Comparing WBRT to C1 with WBRT to C2, the mean left, right, and both parotids' doses were lower when treated to C1. Converting mean dose to BED 3 , the parotid doses were lower than BED 3 constraint of 32.83 Gy: left (30.12 Gy), right (30.69 Gy), and both parotids (30.32 Gy). V20 to combined parotids was lower in patients treated to C1. When accounting for fractionation of WBRT received, the mean corrected V20 volume was less than 20 cc when treating to C1. D50 for C1 was lower than C2 for the left parotid, right parotid, and both parotids. BED 3 conversion for the mean D50 of the left, right, and both parotids was less than 39.09 Gy. In conclusion, WBRT to C1 limits parotid dose, and parotid dose constraints are achievable compared with inferior border at C2. A possible mean parotid dose constraint with BED

  9. Potential clinical efficacy of intensity-modulated conformal therapy

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Buatti, John M.; Bova, Francis J.; Friedman, William A.; Mendenhall, William M.; Zlotecki, Robert A.

    1998-01-01

    Purpose: The purpose of this study was to examine the potential benefit of using intensity-modulated conformal therapy for a variety of lesions currently treated with stereotactic radiosurgery or conventional radiotherapy. Methods and Materials: Intensity-modulated conformal treatment plans were generated for small intracranial lesions, as well as head and neck, lung, breast, and prostate cases, using the Peacock Plan[reg] treatment-planning system (Nomos Corporation). For small intracranial lesions, intensity-modulated conformal treatment plans were compared with stereotactic radiosurgery treatment plans generated for patient treatment at the University of Florida Shands Cancer Center. For other sites (head and neck, lung, breast, and prostate), plans generated using the Peacock Plan[reg] were compared with conventional treatment plans, as well as beam's-eye-view conformal treatment plans. Plan comparisons were accomplished through conventional qualitative review of two-dimensional (2D) dose distributions in conjunction with quantitative techniques, such as dose-volume histograms, dosimetric statistics, normal tissue complication probabilities, tumor control probabilities, and objective numerical scoring. Results: For small intracranial lesions, there is little difference between intensity-modulated conformal treatment planning and radiosurgery treatment planning in the conformation of high isodose lines with the target volume. However, stereotactic treatment planning provides a steeper dose gradient outside the target volume and, hence, a lower normal tissue toxicity index. For extracranial sites, objective numerical scores for beam's-eye-view and intensity-modulated conformal planning techniques are superior to scores for conventional treatment plans. The beam's-eye-view planning technique prevents geographic target misses and better excludes healthy tissues from the treatment portal. Compared with scores for the beam's-eye-view planning technique, scores for

  10. Outcome after intensity modulated radiotherapy for anaplastic thyroid carcinoma

    International Nuclear Information System (INIS)

    He, Xiayun; Li, Duanshu; Hu, Chaosu; Wang, Zhuoying; Ying, Hongmei; Wu, Yi

    2014-01-01

    Anaplastic thyroid carcinoma (ATC) is a malignancy with one of the highest fatality rates. We reviewed our recent clinical experience with intensity modulated radiotherapy (IMRT) combined with surgery and chemotherapy for the management of ATC. 13 patients with ATC who were treated by IMRT in our institution between October 2008 and February 2011, have been analyzed. The target volume for IMRT was planned to include Gross tumor volume (GTV): primary tumor plus any N + disease (66 Gy/33 F/6.6 W), with elective irradiation of thyroid bed, bilateral level II through VI and mediastinal lymph nodes to the level of the carina (54-60 Gy). Seven patients received surgical intervention and eleven patients had chemotherapy. The median radiotherapy dose to GTV was 60 Gy/30 fractions/6 weeks. The median survival time of the 13 patients was 9 months. The direct causes of death were distant metastases (75%) and progression of the locoregional disease (25%). Ten patients were spared dyspnea and tracheostomy because their primary neck lesion did not progress. The results showed that IMRT combined by surgery and chemotherapy for ATC might be beneficial to improve locoregional control. Further new therapies are needed to control metastases

  11. Surgical management of epithelial parotid tumours

    International Nuclear Information System (INIS)

    Obaid, M.A.; Yusuf, A.

    2004-01-01

    Objective: To describe the clinicopathological presentation and treatment options in epithelial parotid tumours with emphasis on surgery. Subjects and Methods: Epithelial parotid tumours diagnosed and operated by an ENT surgeon and a general surgeon in 10 years during their posting in different teaching hospitals were included in the study. Clinical presentation, preoperative investigations, operative procedure, histopathology report, postoperative complications and further management were recorded. The data was collected and reviewed from the records of all the patients maintained by the authors. Results: Fifty-two patients presented with parotid tumour. Average age was 38 years. Commonest presentation was painless lump over the parotid region (85%), pain (15%), facial palsy, and enlarged neck nodes. Majority of tumours were benign, only two were recurrent. Parotid pleomorphic Adenoma (PPA) was the commonest benign tumour, others being Warthin's tumour and monomorphic adenoma. Adenoid cystic carcinoma was the commonest malignant tumour 29% followed by mucoepidermoid carcinoma. Others were carcinoma in PPA squamous cell carcinoma, malignant mixed tumour, malignant Iymphoepithelioma and undifferentiated carcinoma. Superficial parotidectomy (SP) was the commonest operation performed in 69%. Other procedures were total conservative parotidectomy in 11%, total radical surgery in 9% and enucleation in only one patient earliest in the series. Neck node dissection was done in 2 patients. Except for one child, rest of the 13 patients received postoperative radiotherapy and one patient of Iymphoepithelioma received chemotherapy in addition. Commonest postoperative complication was temporary facial weakness in 35% (18/52). Permanent facial palsy occurred in 08 patients. Of these 07 had a malignant process and only one patient had excision biopsy. Conclusion: Benign and malignant epithelial parotid tumours can be diagnosed by there clinical presentation . supplemented with

  12. A novel linear programming approach to fluence map optimization for intensity modulated radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Romeijn, H Edwin; Ahuja, Ravindra K; Dempsey, James F; Kumar, Arvind; Li, Jonathan G

    2003-01-01

    We present a novel linear programming (LP) based approach for efficiently solving the intensity modulated radiation therapy (IMRT) fluence-map optimization (FMO) problem to global optimality. Our model overcomes the apparent limitations of a linear-programming approach by approximating any convex objective function by a piecewise linear convex function. This approach allows us to retain the flexibility offered by general convex objective functions, while allowing us to formulate the FMO problem as a LP problem. In addition, a novel type of partial-volume constraint that bounds the tail averages of the differential dose-volume histograms of structures is imposed while retaining linearity as an alternative approach to improve dose homogeneity in the target volumes, and to attempt to spare as many critical structures as possible. The goal of this work is to develop a very rapid global optimization approach that finds high quality dose distributions. Implementation of this model has demonstrated excellent results. We found globally optimal solutions for eight 7-beam head-and-neck cases in less than 3 min of computational time on a single processor personal computer without the use of partial-volume constraints. Adding such constraints increased the running times by a factor of 2-3, but improved the sparing of critical structures. All cases demonstrated excellent target coverage (>95%), target homogeneity (<10% overdosing and <7% underdosing) and organ sparing using at least one of the two models

  13. DARS: a phase III randomised multicentre study of dysphagia- optimised intensity- modulated radiotherapy (Do-IMRT) versus standard intensity- modulated radiotherapy (S-IMRT) in head and neck cancer

    International Nuclear Information System (INIS)

    Petkar, Imran; Rooney, Keith; Roe, Justin W. G.; Patterson, Joanne M.; Bernstein, David; Tyler, Justine M.; Emson, Marie A.; Morden, James P.; Mertens, Kathrin; Miles, Elizabeth; Beasley, Matthew; Roques, Tom; Bhide, Shreerang A.; Newbold, Kate L.; Harrington, Kevin J.; Hall, Emma; Nutting, Christopher M.

    2016-01-01

    Persistent dysphagia following primary chemoradiation (CRT) for head and neck cancers can have a devastating impact on patients’ quality of life. Single arm studies have shown that the dosimetric sparing of critical swallowing structures such as the pharyngeal constrictor muscle and supraglottic larynx can translate to better functional outcomes. However, there are no current randomised studies to confirm the benefits of such swallow sparing strategies. The aim of Dysphagia/Aspiration at risk structures (DARS) trial is to determine whether reducing the dose to the pharyngeal constrictors with dysphagia-optimised intensity- modulated radiotherapy (Do-IMRT) will lead to an improvement in long- term swallowing function without having any detrimental impact on disease-specific survival outcomes. The DARS trial (CRUK/14/014) is a phase III multicentre randomised controlled trial (RCT) for patients undergoing primary (chemo) radiotherapy for T1-4, N0-3, M0 pharyngeal cancers. Patients will be randomised (1:1 ratio) to either standard IMRT (S-IMRT) or Do-IMRT. Radiotherapy doses will be the same in both groups; however in patients allocated to Do-IMRT, irradiation of the pharyngeal musculature will be reduced by delivering IMRT identifying the pharyngeal muscles as organs at risk. The primary endpoint of the trial is the difference in the mean MD Anderson Dysphagia Inventory (MDADI) composite score, a patient-reported outcome, measured at 12 months post radiotherapy. Secondary endpoints include prospective and longitudinal evaluation of swallow outcomes incorporating a range of subjective and objective assessments, quality of life measures, loco-regional control and overall survival. Patients and speech and language therapists (SLTs) will both be blinded to treatment allocation arm to minimise outcome-reporting bias. DARS is the first RCT investigating the effect of swallow sparing strategies on improving long-term swallowing outcomes in pharyngeal cancers. An integral

  14. Whole-brain Irradiation Field Design: A Comparison of Parotid Dose

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Cheng-Chia; Wuu, Yen-Ruh; Jani, Ashish; Saraf, Anurag; Tai, Cheng-Hung; Lapa, Matthew E.; Andrew, Jacquelyn I.S.; Tiwari, Akhil; Saadatmand, Heva J. [Department of Radiation Oncology, Columbia University Medical Center, 622 West 168th Street, BNH B-11, New York, NY 10032 (United States); Isaacson, Steven R. [Department of Radiation Oncology, Columbia University Medical Center, 622 West 168th Street, BNH B-11, New York, NY 10032 (United States); Department of Neurological Surgery, Columbia University Medical Center, New York, NY 10032 (United States); Cheng, Simon K., E-mail: sc3225@cumc.columbia.edu [Department of Radiation Oncology, Columbia University Medical Center, 622 West 168th Street, BNH B-11, New York, NY 10032 (United States); Herbert Irving Comprehensive Cancer Center, Columbia University Medical Center, New York, NY 10032 (United States); Wang, Tony J.C., E-mail: tjw2117@cumc.columbia.edu [Department of Radiation Oncology, Columbia University Medical Center, 622 West 168th Street, BNH B-11, New York, NY 10032 (United States); Herbert Irving Comprehensive Cancer Center, Columbia University Medical Center, New York, NY 10032 (United States)

    2017-07-01

    Whole-brain radiation therapy (WBRT) plays an important role in patients with diffusely metastatic intracranial disease. Whether the extent of the radiation field design to C1 or C2 affects parotid dose and risk for developing xerostomia is unknown. The goal of this study is to examine the parotid dose based off of the inferior extent of WBRT field to either C1 or C2. Patients treated with WBRT with either 30 Gy or 37.5 Gy from 2011 to 2014 at a single institution were examined. Parotid dose constraints were compared with Radiation Therapy Oncology Group (RTOG) 0615 nasopharyngeal carcinoma for a 33-fraction treatment: mean <26 Gy, volume constraint at 20 Gy (V20) < 20 cc, and dose at 50% of the parotid volume (D50) < 30 Gy. Biologically effective dose (BED) conversions with an α/β of 3 for normal parotid were performed to compare with 10-fraction and 15-fraction treatments of WBRT. The constraints are as follows: mean < BED 32.83 Gy, V15.76 (for 10-fraction WBRT) or V17.35 (for 15-fraction WBRT) < 20 cc, and D50 < BED 39.09 Gy. Nineteen patients treated to C1 and 26 patients treated to C2 were analyzed. Comparing WBRT to C1 with WBRT to C2, the mean left, right, and both parotids' doses were lower when treated to C1. Converting mean dose to BED{sub 3}, the parotid doses were lower than BED{sub 3} constraint of 32.83 Gy: left (30.12 Gy), right (30.69 Gy), and both parotids (30.32 Gy). V20 to combined parotids was lower in patients treated to C1. When accounting for fractionation of WBRT received, the mean corrected V20 volume was less than 20 cc when treating to C1. D50 for C1 was lower than C2 for the left parotid, right parotid, and both parotids. BED{sub 3} conversion for the mean D50 of the left, right, and both parotids was less than 39.09 Gy. In conclusion, WBRT to C1 limits parotid dose, and parotid dose constraints are achievable compared with inferior border at C2. A possible mean parotid dose

  15. Dosimetric comparison between step-shoot intensity-modulated radiotherapy and volumetric-modulated arc therapy for upper thoracic and cervical esophageal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Min; Li, Qilin; Ning, Zhonghua; Gu, Wendong; Huang, Jin; Mu, Jinming; Pei, Honglei, E-mail: hongleipei@126.com

    2016-07-01

    To compare and analyze the dosimetric characteristics of volumetric modulated arc therapy (VMAT) vs step-shoot intensity-modulated radiation therapy (sIMRT) for upper thoracic and cervical esophageal carcinoma. Single-arc VMAT (VMAT1), dual-arc VMAT (VMAT2), and 7-field sIMRT plans were designed for 30 patients with upper thoracic or cervical esophageal carcinoma. Planning target volume (PTV) was prescribed to 50.4 Gy in 28 fractions, and PTV1 was prescribed to 60 Gy in 28 fractions. The parameters evaluated included dose homogeneity and conformality, dose to organs at risk (OARs), and delivery efficiency. (1) In comparison to sIMRT, VMAT provided a systematic improvement in PTV1 coverage. The homogeneity index of VMAT1 was better than that of VMAT2. There were no significant differences among sIMRT, VMAT1, and VMAT2 in PTV coverage. (2) VMAT1 and VMAT2 reduced the maximum dose of spinal cord as compared with sIMRT (p < 0.05). The rest dose-volume characteristics of OARs were similar. (3) Monitor units of VMAT2 and VMAT1 were more than sIMRT. However, the treatment time of VMAT1, VMAT2, and sIMRT was (2.0 ± 0.2), (2.8 ± 0.3), and (9.8 ± 0.8) minutes, respectively. VMAT1 was the fastest, and the difference was statistically significant. In the treatment of upper thoracic and cervical esophageal carcinoma by the AXESSE linac, compared with 7-field sIMRT, VMAT showed better PTV1 coverage and superior spinal cord sparing. Single-arc VMAT had similar target volume coverage and the sparing of OAR to dual-arc VMAT, with shortest treatment time and highest treatment efficiency in the 3 kinds of plans.

  16. Radiation effects on the parotid gland of mammals. Pt. 2. Modifications of plasma and parotid amylase activity

    Energy Technology Data Exchange (ETDEWEB)

    Balzi, M; Cremonini, D; Tomassi, I; Becciolini, A; Giannardi, G [Florence Univ. (Italy). Istituto di Radiologia; Pelu, G [I.N.R.C.A., Florence (Italy). Inst. of Radiology

    1979-08-01

    The early modifications of the activity of plasma and parotid amylase have been evaluated in rats after whole-body irradiation in different experimental conditions. The modifications observed in the rat are less evident than in humans. The results have shown an initial decrease and a subsequent increase appearing significant 74 hours after irradiation. This could be due to a direct action of ionizing radiation on the parotid glands. However we cannot exclude that the increase of ..cap alpha..-amylase could be determined by the intestinal radiation syndrome. In fact, this syndrome leads to a reduced food uptake, and consequently ..cap alpha..-amylase could accumulate in parotids.

  17. Fan beam intensity modulated proton therapy

    Science.gov (United States)

    Hill, Patrick M.

    A fan beam proton therapy is developed which delivers intensity modulated proton therapy using distal edge tracking. The system may be retrofit onto existing proton therapy gantries without alterations to infrastructure in order to improve treatments through intensity modulation. A novel range and intensity modulation system is designed using acrylic leaves that are inserted or retracted from subsections of the fan beam. Leaf thicknesses are chosen in a base-2 system and motivated in a binary manner. Dose spots from individual beam channels range between 1 and 5 cm. Integrated collimators attempting to limit crosstalk among beam channels are investigated, but found to be inferior to uncollimated beam channel modulators. A treatment planning system performing data manipulation in MATLAB and dose calculation in MCNPX is developed. Beamlet dose is calculated on patient CT data and a fan beam source is manually defined to produce accurate results. An energy deposition tally follows the CT grid, allowing straightforward registration of dose and image data. Simulations of beam channels assume that a beam channel either delivers dose to a distal edge spot or is intensity modulated. A final calculation is performed separately to determine the deliverable dose accounting for all sources of scatter. Treatment plans investigate the effects that varying system parameters have on dose distributions. Beam channel apertures may be as large as 20 mm because the sharp distal falloff characteristic of proton dose provides sufficient intensity modulation to meet dose objectives, even in the presence of coarse lateral resolution. Dose conformity suffers only when treatments are delivered from less than 10 angles. Jaw widths of 1--2 cm produce comparable dose distributions, but a jaw width of 4 cm produces unacceptable target coverage when maintaining critical structure avoidance. Treatment time for a prostate delivery is estimated to be on the order of 10 minutes. Neutron production

  18. Optimal field splitting for large intensity-modulated fields

    International Nuclear Information System (INIS)

    Kamath, Srijit; Sahni, Sartaj; Ranka, Sanjay; Li, Jonathan; Palta, Jatinder

    2004-01-01

    The multileaf travel range limitations on some linear accelerators require the splitting of a large intensity-modulated field into two or more adjacent abutting intensity-modulated subfields. The abutting subfields are then delivered as separate treatment fields. This workaround not only increases the treatment delivery time but it also increases the total monitor units (MU) delivered to the patient for a given prescribed dose. It is imperative that the cumulative intensity map of the subfields is exactly the same as the intensity map of the large field generated by the dose optimization algorithm, while satisfying hardware constraints of the delivery system. In this work, we describe field splitting algorithms that split a large intensity-modulated field into two or more intensity-modulated subfields with and without feathering, with optimal MU efficiency while satisfying the hardware constraints. Compared to a field splitting technique (without feathering) used in a commercial planning system, our field splitting algorithm (without feathering) shows a decrease in total MU of up to 26% on clinical cases and up to 63% on synthetic cases

  19. Computed tomographic diagnosis of parotid gland tumor

    International Nuclear Information System (INIS)

    Matsunaga, Hitoki; Nishimura, Tadao; Takasu, Akihiko; Yagizawa, Mikio; Suzuki, Akio

    1983-01-01

    Investigation with CT has been performed on 20 cases of parotid gland tumors. The intravenous contrast enhancement method was performed in all cases. Six cases were examined by CT and simultaneous sialography. The results were as follows: 1) If and when the margin of the tumor was indistinct and irregular, malignancy was suspected. However, it was difficult to diagnose malignancy by CT examination only. 2) CT for parotid gland tumor was effective in indentifying invasion of tumor into the parapharyngeal space and intracranial space. 3) CT with simultaneous sialography was very effective in locating the parotid gland tumor. 4) CT of axial sections for parotid gland tumor was more reliable if coronaly sections are taken together. 5) CT of malignant and benign tumors were diffusely enhanced by the intravenous contrast enhancement method. However, this was not an indispensable method. (author)

  20. Submandibular gland-sparing radiation therapy for locally advanced oropharyngeal squamous cell carcinoma: patterns of failure and xerostomia outcomes

    International Nuclear Information System (INIS)

    Gensheimer, Michael F; Liao, Jay J; Garden, Adam S; Laramore, George E; Parvathaneni, Upendra

    2014-01-01

    Saliva from submandibular glands (SMG) is necessary to minimize xerostomia. It is unclear whether SMG can be safely spared in patients undergoing bilateral neck radiotherapy for locally advanced oropharyngeal cancer without increasing the risk of marginal recurrence. We evaluated the outcomes of contralateral submandibular gland (cSMG) sparing intensity-modulated radiation therapy (IMRT). All patients with stage III/IV oropharyngeal squamous cell carcinoma treated with bilateral neck IMRT from 2006–2012 at our institution were included. Appropriately selected patients with favorable primary tumor characteristics and no definite contralateral neck disease were treated with cSMG-sparing IMRT. Patterns of failure and xerostomia outcomes were retrospectively analyzed. 114 patients were treated. 89% had stage IV disease and 89% received definitive radiation therapy. 76 patients (67%) received cSMG sparing IMRT. With a median follow-up of 30 months, there were 10 local, 9 regional, and 10 distant recurrences. 2-year overall survival was 86% and 2-year loco-regional control was 87%. In cSMG spared patients, the mean cSMG dose was 30.7 Gy. Late grade 2+ xerostomia was significantly reduced in the cSMG spared group compared to those without SMG sparing (6 months: 23% vs. 72%, 12 months: 6% vs. 41%, 24 months: 3% vs. 36%, all p < 0.0007). There were no peri-SMG marginal recurrences in the cSMG-spared cohort. cSMG sparing IMRT did not increase marginal failures in this series of locally advanced oropharyngeal SCC patients. Xerostomia was significantly reduced in cSMG spared patients

  1. Tuberculosis of the Parotid Gland: Computed Tomographic Findings

    International Nuclear Information System (INIS)

    Wei, Y.; Xiao, J.; Pui, M.H.; Gong, Q.

    2008-01-01

    Background: Tuberculosis (TB) of the parotid gland is rare, even in endemic regions. Approximately 100 cases have been reported in the English literature. The computed tomographic (CT) features, however, have seldom been studied. Purpose: To determine the diagnostic CT features of tuberculosis of the parotid gland. Material and Methods: CT studies of four histologically proven cases of tuberculosis of the parotid gland were retrospectively reviewed. Results: A total of 15 enlarged lymph nodes were found in the superficial lobes of the parotid glands. The nodes were arranged linearly within the gland. Enhancement patterns included homogeneous enhancement (9/15, 60%), homogeneous enhancement with eccentric microcysts (3/15, 20%), and thick-walled rim enhancement with central lucency (3/15, 20%). Thickened adjacent fascial plane and platysma were seen in two patients. Ipsilateral cervical lymphadenopathy was seen in all patients. Conclusion: In patients presenting with unilateral parotid nodules, TB should be considered when linearly arranged enhancing nodules are demonstrated in the superficial lobes of the glands on CT scan

  2. Dose–response analysis of parotid gland function: What is the best measure of xerostomia?

    International Nuclear Information System (INIS)

    Miah, Aisha B.; Gulliford, Sarah L.; Clark, Catharine H.; Bhide, Shreerang A.; Zaidi, Shane H.; Newbold, Kate L.; Harrington, Kevin J.; Nutting, Christopher M.

    2013-01-01

    Purpose: To describe the dose–response relationships for the different measures of salivary gland recovery following radical radiotherapy for locally advanced head and neck squamous cell cancers (LA-HNSCC). Methods and materials: Dosimetric analysis of data from the PARSPORT trial, a Phase III study of conventional RT (RT) and intensity modulated radiotherapy (IMRT) for LA-HNSCC was undertaken to determine the relationship between parotid gland mean dose and toxicity endpoints: high-grade subjective and objective xerostomia and xerostomia-related quality of life scores. LKB-NTCP parameters (TD50, m and n) were generated and tolerance doses (D50) reported using non-linear logistic regression analysis. Results: Data were available on 63 patients from the PARSPORT trial. Parotid saliva flow rate provided the strongest association between mean dose and recovery, D50 = 23.4 Gy (20.6–26.2) and k = 3.2 (1.9–4.5), R 2 = 0.85. Corresponding LKB parameters were TD50 = 26.3 Gy (95% CI: 24.0–30.1), m = 0.25 (0.18–1.0 and n = 1). LENTSOMA subjective xerostomia also demonstrated a strong association D50 = 33.3 Gy (26.7–39.8), k = 2.8 (91.4–4.4), R 2 = 0.77). Conclusion: We recommend using the LENT SOMA subjective xerostomia score to predict recovery of salivation due to its strong association with dosimetry and ease of recording

  3. Dose-response analysis of parotid gland function: what is the best measure of xerostomia?

    Science.gov (United States)

    Miah, Aisha B; Gulliford, Sarah L; Clark, Catharine H; Bhide, Shreerang A; Zaidi, Shane H; Newbold, Kate L; Harrington, Kevin J; Nutting, Christopher M

    2013-03-01

    To describe the dose-response relationships for the different measures of salivary gland recovery following radical radiotherapy for locally advanced head and neck squamous cell cancers (LA-HNSCC). Dosimetric analysis of data from the PARSPORT trial, a Phase III study of conventional RT (RT) and intensity modulated radiotherapy (IMRT) for LA-HNSCC was undertaken to determine the relationship between parotid gland mean dose and toxicity endpoints: high-grade subjective and objective xerostomia and xerostomia-related quality of life scores. LKB-NTCP parameters (TD50, m and n) were generated and tolerance doses (D50) reported using non-linear logistic regression analysis. Data were available on 63 patients from the PARSPORT trial. Parotid saliva flow rate provided the strongest association between mean dose and recovery, D50=23.4 Gy (20.6-26.2) and k=3.2 (1.9-4.5), R(2)=0.85. Corresponding LKB parameters were TD50=26.3 Gy (95% CI: 24.0-30.1), m=0.25 (0.18-1.0 and n=1). LENTSOMA subjective xerostomia also demonstrated a strong association D50=33.3 Gy (26.7-39.8), k=2.8 (91.4-4.4), R(2)=0.77). We recommend using the LENT SOMA subjective xerostomia score to predict recovery of salivation due to its strong association with dosimetry and ease of recording. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  4. Randomized phase II trial of urethral sparing intensity modulated radiation therapy in low-risk prostate cancer: implications for focal therapy

    Directory of Open Access Journals (Sweden)

    Vainshtein Jeffrey

    2012-06-01

    Full Text Available Abstract Background Low-risk prostate cancer (PCa patients have excellent outcomes, with treatment modality often selected by perceived effects on quality of life. Acute urinary symptoms are common during external beam radiotherapy (EBRT, while chronic symptoms have been linked to urethral dose. Since most low-risk PCa occurs in the peripheral zone (PZ, we hypothesized that EBRT using urethral sparing intensity modulated radiation therapy (US-IMRT could improve urinary health-related quality of life (HRQOL while maintaining high rates of PCa control. Methods Patients with National Comprehensive Cancer Network (NCCN defined low-risk PCa with no visible lesion within 5 mm of the prostatic urethra on MRI were randomized to US-IMRT or standard (S- IMRT. Prescription dose was 75.6 Gy in 41 fractions to the PZ + 3–5 mm for US-IMRT and to the prostate + 3 mm for S-IMRT. For US-IMRT, mean proximal and distal urethral doses were limited to 65 Gy and 74 Gy, respectively. HRQOL was assessed using the Expanded Prostate Cancer Index (EPIC Quality of Life questionnaire. The primary endpoint was change in urinary HRQOL at 3 months. Results From June 2004 to November 2006, 16 patients were randomized, after which a futility analysis concluded that continued accrual was unlikely to demonstrate a difference in the primary endpoint. Mean change in EPIC urinary HRQOL at 3 months was −0.5 ± 11.2 in the US-IMRT arm and +3.9 ± 15.3 in the S-IMRT arm (p = 0.52. Median PSA nadir was higher in the US-IMRT arm (1.46 vs. 0.78, p = 0.05. At 4.7 years median follow-up, three US-IMRT and no S-IMRT patients experienced PSA failure (p = 0.06; HR 8.8, 95% CI 0.9–86. Two out of 3 patients with PSA failure had biopsy-proven local failure, both located contralateral to the original site of disease. Conclusions Compared with S-IMRT, US-IMRT failed to improve urinary HRQOL and resulted in higher PSA nadir and inferior biochemical

  5. Intensity-modulated radiation therapy (IMRT) for locally advanced paranasal sinus tumors: incorporating clinical decisions in the optimization process

    International Nuclear Information System (INIS)

    Tsien, Christina; Eisbruch, Avraham; McShan, Daniel; Kessler, Marc; Marsh, Robin C.; Fraass, Benedick

    2003-01-01

    Purpose: Intensity-modulated radiotherapy (IMRT) plans require decisions about priorities and tradeoffs among competing goals. This study evaluates the incorporation of various clinical decisions into the optimization system, using locally advanced paranasal sinus tumors as a model. Methods and Materials: Thirteen patients with locally advanced paranasal sinus tumors were retrospectively replanned using inverse planning. Two clinical decisions were assumed: (1) Spare both optic pathways (OP), or (2) Spare only the contralateral OP. In each case, adequate tumor coverage (treated to 70 Gy in 35 fractions) was required. Two beamlet IMRT plans were thus developed for each patient using a class solution cost function. By altering one key variable at a time, different levels of risk of OP toxicity and planning target volume (PTV) compromise were compared in a systematic manner. The resulting clinical tradeoffs were analyzed using dosimetric criteria, tumor control probability (TCP), equivalent uniform dose (EUD), and normal tissue complication probability. Results: Plan comparisons representing the two clinical decisions (sparing both OP and sparing only the contralateral OP), with respect to minimum dose, TCP, V 95 , and EUD, demonstrated small, yet statistically significant, differences. However, when individual cases were analyzed further, significant PTV underdosage (>5%) was present in most cases for plans sparing both OP. In 6/13 cases (46%), PTV underdosage was between 5% and 15%, and in 3 cases (23%) was greater than 15%. By comparison, adequate PTV coverage was present in 8/13 cases (62%) for plans sparing only the contralateral OP. Mean target EUD comparisons between the two plans (including 9 cases where a clinical tradeoff between PTV coverage and OP sparing was required) were similar: 68.6 Gy and 69.1 Gy, respectively (p=0.02). Mean TCP values for those 9 cases were 56.5 vs. 61.7, respectively (p=0.006). Conclusions: In IMRT plans for paranasal sinus tumors

  6. The combined use of US and MR imaging for the diagnosis of masses in the parotid region

    International Nuclear Information System (INIS)

    Goto, T.K.; Yoshiura, K.; Nakayama, E.; Yuasa, K.; Tabata, O.; Nakano, T.; Kawazu, T.; Tanaka, T.; Miwa, K.; Shimizu, M.; Chikui, T.; Okamura, K.; Kanda, S.

    2000-01-01

    To evaluate the usefulness of the combination of the two non-invasive modalities US and MR imaging to diagnose masses in the parotid region. The US and MR findings of 21 patients with parotid masses were analyzed retrospectively by two radiologists without any clinical or histopathological information. The specific points evaluated were location, shape, margin, internal architecture, and intensity level on both US and MR, posterior echo enhancement on US, and capsule-like lining of the tumor on MR. The findings concerning the shape and margin on US and MR were in fairly good agreement. Concerning the findings of the internal architecture, US could reveal the minute structures of the tumor while MR demonstrated differences in the signal intensities of histological tissue types of the various tumors. The posterior echo enhancement on US and the capsule-like lining on MR of the tumors were also useful for the diagnosis. Our results suggest that the combination of US and MR is useful for examining soft tissue masses in the parotid region to make a more accurate diagnosis, and not just differentiate malignant lesions from those which are benign

  7. Intra-parotid dermoid cyst: excision through a face lift incision.

    Science.gov (United States)

    Shakeel, M; Keh, S M; Chapman, A; Hussain, A

    2014-11-01

    Intra-parotid dermoid cysts are extremely rare. Clinically, they present like any other parotid lump and pre-operative diagnosis is rarely possible. A 62 years old Caucasian man presented with a painless lump in his right parotid region. The Magnetic Resonance Imaging (MRI) scan revealed a 3 x 3 cm mass in the parotid tail. Cytological examination was unhelpful. The patient underwent successful excision of the cyst through a small face lift incision. No drain was inserted and the patient was discharged home the same day. The patient made an uneventful recovery and was highly satisfied with the aesthetic outcome. The definite histopathological diagnosis was an intra-parotid dermoid cyst.

  8. Light intensity modulation in phototherapy

    Science.gov (United States)

    Lukyanovich, P. A.; Zon, B. A.; Kunin, A. A.; Pankova, S. N.

    2015-04-01

    A hypothesis that blocking ATP synthesis is one of the main causes of the stimulating effect is considered based on analysis of the primary photostimulation mechanisms. The light radiation intensity modulation is substantiated and the estimates of such modulation parameters are made. An explanation is offered to the stimulation efficiency decrease phenomenon at the increase of the radiation dose during the therapy. The results of clinical research of the medical treatment in preventive dentistry are presented depending on the spectrum and parameters of the light flux modulation.

  9. Ductal carcinoma of the parotid gland.

    Science.gov (United States)

    Eriksen, H E; Greisen, O; Hastrup, N

    1987-06-01

    A case of ductal carcinoma of the parotid gland is described. The medical literature contains only 13 previous reports on this kind of adenocarcinoma of the parotid gland. The tumour is characterized by its histologic resemblance to ductal carcinomas of the breast and prostate. The course of previously described cases suggests that this tumour has a highly aggressive biological behaviour.

  10. Branchial cysts within the parotid salivary gland

    Science.gov (United States)

    2012-01-01

    Cystic lesions within the parotid gland are uncommon and clinically they are frequently misdiagnosed as tumours. Many theories have been proposed as to their embryological origin. A 20-year retrospective review was undertaken of all pathological codes (SNOMED) of all of patients presenting with any parotid lesions requiring surgery. After analysis seven subjects were found to have histopathologically proven parotid branchial cysts in the absence of HIV infection and those patients are the aim of this review. Four of the most common embryological theories are also discussed with regard to these cases, as are their management. PMID:22607735

  11. Hippocampus sparing in whole-brain radiotherapy. A review

    Energy Technology Data Exchange (ETDEWEB)

    Oskan, F. [University of Munich, Department of Radiation Oncology and CCC Neuro-Oncology, Munich (Germany); Saarland University Medical Center, Department of Radiation Oncology, Homburg/Saar (Germany); Ganswindt, U.; Schwarz, S.B.; Manapov, F.; Belka, C.; Niyazi, M. [University of Munich, Department of Radiation Oncology and CCC Neuro-Oncology, Munich (Germany)

    2014-04-15

    Radiation treatment techniques for whole-brain radiation therapy (WBRT) have not changed significantly since development of the procedure. However, the recent development of novel techniques such as intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT) and helical tomotherapy, as well as an increasing body of evidence concerning neural stem cells (NSCs) have altered the conventional WBRT treatment paradigm. In this regard, hippocampus-sparing WBRT is a novel technique that aims to spare critical hippocampus regions without compromising tumour control. Published data on this new technique are limited to planning and feasibility studies; data on patient outcome are still lacking. However, several prospective trials to analyse the feasibility of this technique and to document clinical outcome in terms of reduced neurotoxicity are ongoing. (orig.) [German] Die Technik der Ganzhirnbestrahlung (''whole-brain radiation therapy'', WBRT) hat sich seit der Entwicklung nicht wesentlich veraendert. Allerdings stellten die Neuentwicklung von Techniken wie die intensitaetsmodulierte Strahlentherapie (IMRT), die volumenmodulierte Arc-Therapie (VMAT) oder die helikale Tomotherapie sowie immer groesseres Wissen ueber das neurale Stammzellkompartiment (NSCs) das herkoemmliche Ganzhirn-Paradigma in Frage. Die hippocampusschonende Ganzhirnbestrahlung ist eine neuartige Technik, welche die kritische Region des Hippocampus schont, ohne die Tumorkontrolle zu gefaehrden. Ueber diese Technik gibt es bisher nur eine begrenzte Datenlage im Sinne von Planungs- und Machbarkeitsstudien. Klinische Daten bzgl. der Behandlungsergebnisse fehlen nach wie vor, aber einige prospektive Studien sind im Gange, um nicht nur die Machbarkeit zu belegen, sondern auch das klinische Outcome im Sinne einer verringerten Neurotoxizitaet nachzuweisen. (orig.)

  12. Preliminary results of phase I/II study of simultaneous modulated accelerated (SMART) for nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Hong; Lee, Sang Wook; Back, Geum Mun [College of Medicine, University of Ulsan, Asan Medical Center, Seoul (Korea, Republic of)] (and others)

    2006-03-15

    To present preliminary results of intensity-modulated radiotherapy (IMRT) using the simultaneous modulated accelerated radiation therapy (SMART) boost technique in patients with nasopharyngeal carcinoma (NPC). Twenty patients who underwent IMRT for non-metastatic NPC at the Asan Medical Center between September 2001 and December 2003 were prospectively evaluated. IMRT was delivered using the 'step and shoot' SMART technique at prescribed doses of 72 Gy (2.4 Gy/day) to the gross tumor volume (GTV), 60 Gy (2 Gy/day) to the clinical target volume (CTV) and metastatic nodal station, and 46 Gy (2 Gy/day) to the clinically negative neck region. Eighteen patients also received concurrent chemotherapy using cisplatin once per week. The median follow-up period was 27 months. Nineteen patients completed the treatment without interruption; the remaining patient interrupted treatment for 2 weeks owing to severe pharyngitis and malnutrition. Five patients (25%) had RTOG grade 3 mucositis, whereas nine (45%) had grade 3 pharyngitis. Seven patients (35%) lost more than 10% of their pretreatment weight, whereas 11 (55%) required intravenous fluids and/or tube feeding. There was no grade 3 or 4 chronic xerostomia. All patients showed complete response. Two patients had distant metastases and loco-regional recurrence, respectively. IMRT using the SMART boost technique allows parotid sparing, as shown clinically and by dosimetry, and may also be more effective biologically. A larger population of patients and a longer follow-up period are needed to evaluate ultimate tumor control and late toxicity.

  13. Intensity modulated radiation therapy for oropharyngeal cancer: the sensitivity of plan objectives and constraints to set-up uncertainty

    International Nuclear Information System (INIS)

    Ploquin, Nicolas; Song, William; Lau, Harold; Dunscombe, Peter

    2005-01-01

    The goal of this study was to assess the impact of set-up uncertainty on compliance with the objectives and constraints of an intensity modulated radiation therapy protocol for early stage cancer of the oropharynx. As the convolution approach to the quantitative study of set-up uncertainties cannot accommodate either surface contours or internal inhomogeneities, both of which are highly relevant to sites in the head and neck, we have employed the more resource intensive direct simulation method. The impact of both systematic (variable from 0 to 6 mm) and random (fixed at 2 mm) set-up uncertainties on compliance with the criteria of the RTOG H-0022 protocol has been examined for eight geometrically complex structures: CTV66 (gross tumour volume and palpable lymph nodes suspicious for metastases), CTV54 (lymph node groups or surgical neck levels at risk of subclinical metastases), glottic larynx, spinal cord, brainstem, mandible and left and right parotids. In a probability-based approach, both dose-volume histograms and equivalent uniform doses were used to describe the dose distributions achieved by plans for two patients, in the presence of set-up uncertainty. The equivalent uniform dose is defined to be that dose which, when delivered uniformly to the organ of interest, will lead to the same response as the non-uniform dose under consideration. For systematic set-up uncertainties greater than 2 mm and 5 mm respectively, coverage of the CTV66 and CTV54 could be significantly compromised. Directional sensitivity was observed in both cases. Most organs at risk (except the glottic larynx which did not comply under static conditions) continued to meet the dose constraints up to 4 mm systematic uncertainty for both plans. The exception was the contra lateral parotid gland, which this protocol is specifically designed to protect. Sensitivity to systematic set-up uncertainty of 2 mm was observed for this organ at risk in both clinical plans

  14. The radioimmunoassay of biologically active compounds in parotid fluid and plasma

    International Nuclear Information System (INIS)

    Walker, R.F.; Read, G.F.; Riad-Fahmy, D.

    1978-01-01

    Parotid fluid collection is a simple stress-free procedure. The potential value of parotid fluid estimations of clomipramine, a tricyclic antidepressant, d-norgestrel, a synthetic contraceptive steroid and cortisol have been evaluated for assessment of clinical status and patient compliance. These compounds circulate bound largely to plasma proteins. Their concentration in parotid fluid, which reflects the non-protein bound fraction, is low but assay sensitivity (10, 1 and 30 pg/tube respectively) is adequate. Excellent agreement (r>0.9) was observed when parotid fluid samples were assayed with and without chromatographic purification. Clomipramine levels following oral dosage (150 mg) rose steadily to a maximum in plasma but showed wide fluctuations in parotid fluid. Clomipramine therapy can only be assessed by plasma assays, but patient compliance may be checked by parotid fluid concentrations. Following an oral dose of d-norgestrel (0.3 mg), parotid fluid levels rose steadily to a maximum but plasma response was biphasic making correlation impossible. The sensitivity and high throughput of the d-norgestrel methodology suggests its use in evaluating patient compliance in large-scale fertility control programmes. Changes in circulating cortisol concentrations were rapidly and accurately reflected in parotid fluid in normal volunteers. Parotid fluid cortisol showed a marked diurnal rhythm, suppression to low levels after dexamethasone, and elevation following Synacthen. Low levels after Synacthen stimulation in a patient with secondary adrenal atrophy and constant high levels in Cushingoid patients indicate that parotid fluid cortisol levels could be used for accurate adrenocortical evaluation. The value in rapid screening procedures is stressed since the assay can be performed directly on only 10 μl of parotid fluid. (author)

  15. A treatment planning study comparing helical tomotherapy with intensity-modulated radiotherapy for the treatment of anal cancer

    International Nuclear Information System (INIS)

    Joseph, Kurian Jones; Syme, Alasdair; Small, Cormac; Warkentin, Heather; Quon, Harvey; Ghosh, Sunita; Field, Colin; Pervez, Nadeem; Tankel, Keith; Patel, Samir; Usmani, Nawaid; Severin, Diane; Nijjar, Tirath; Fallone, Gino; Pedersen, John

    2010-01-01

    Purpose: A planning study to compare helical tomotherapy (HT) and intensity-modulated radiotherapy (IMRT) for the treatment of anal canal cancer. Materials and methods: Sixteen (8 males and 8 females) patients with anal cancer previously treated radically were identified. HT and IMRT plans were generated and dosimetric comparisons of the plans were performed. The planning goals were to deliver 54 Gy to the tumor (PTV 54Gy ) and 48 Gy to the nodes at risk (PTV Node ) in 30 fractions. Results: PTVs: HT plans were more homogeneous for both men and women. Male patients: HT vs. IMRT: D max : 55.87 ± 0.58 vs. 59.17 ± 3.24 (p = 0.036); D min : 52.91 ± 0.36 vs. 44.09 ± 6.84 (p = 0.012); female patients: HT vs. IMRT: D max : 56.14 ± 0.71 vs. 59.47 ± 0.81 (p = 0.012); D min : 52.36 ± 0.87 vs. 50.97 ± 1.42 (p = 0.028). OARs: In general, HT plans delivered a lower dose to the peritoneal cavity, external genitalia and the bladder and IMRT plans resulted in greater sparing of the pelvic bones (iliac crest/femur) for both men and women. Iliac crest/femur: the difference was significant only for the mean V10 Gy of iliac crest in women (p ≤ 0.012). External genitalia: HT plans achieved better sparing in women compared to men (p ≤ 0.046). For men, the mean doses were 18.96 ± 3.17 and 15.72 ± 3.21 for the HT and IMRT plan, respectively (p ≤ 0.017). Skin: both techniques achieved comparable sparing of the non-target skin (p = NS). Conclusions: HT and IMRT techniques achieved comparable target dose coverage and organ sparing, whereas HT plans were more homogeneous for both men and women.

  16. Sparing land for biodiversity at multiple spatial scales

    Directory of Open Access Journals (Sweden)

    Johan eEkroos

    2016-01-01

    Full Text Available A common approach to the conservation of farmland biodiversity and the promotion of multifunctional landscapes, particularly in landscapes containing only small remnants of non-crop habitats, has been to maintain landscape heterogeneity and reduce land-use intensity. In contrast, it has recently been shown that devoting specific areas of non-crop habitats to conservation, segregated from high-yielding farmland (‘land sparing’, can more effectively conserve biodiversity than promoting low-yielding, less intensively managed farmland occupying larger areas (‘land sharing’. In the present paper we suggest that the debate over the relative merits of land sparing or land sharing is partly blurred by the differing spatial scales at which it is suggested that land sparing should be applied. We argue that there is no single correct spatial scale for segregating biodiversity protection and commodity production in multifunctional landscapes. Instead we propose an alternative conceptual construct, which we call ‘multiple-scale land sparing’, targeting biodiversity and ecosystem services in transformed landscapes. We discuss how multiple-scale land sparing may overcome the apparent dichotomy between land sharing and land sparing and help to find acceptable compromises that conserve biodiversity and landscape multifunctionality.

  17. Parotid gland lipoma: two case report

    International Nuclear Information System (INIS)

    Islim, F.; Ors, S.; Salik, A.; Selcuk, H.; Sever, N.

    2012-01-01

    Full text: Introduction: Lipoma is the most common mesenchymal neoplasm in the human body but very rarely in the parotid gland. Objective: The aim of this study was to document retrospectively the imaging findings of lipomas with the use of computed tomography, ultrasonography, and magnetic resonance imaging. Material and methods: Ultrasonography, Computed Tomography (CT), and Magnetic Resonance Imaging were performed to the patients after clinical evaluation and physical examination. Both for two patients after fine needle aspiration biopsy, surgical excisions were practiced. Case 1: 14-wear-old woman was applied to the hospital with swelling of the right jaw. In physical examination a palpable mass was detected on the parotid gland. In sonography, heterogeneous, hypoechoic solid lesion was observed. This tumor produced strong signals on T1- and T2-weighted MR images and weak signals on fat suppression images. Case 2: 65-wear-old man presented with a 10 month history of a painless, slow growing mass in the left preauricular area. In sonography, heterogeneous, hypoechoic solid lesion with hyperechoic areas was observed. Also this tumor produced strong signals on T1- and T2-weighted MR images and weak signals on fat suppression images with low ADC level. Both for two patients after fine-needle aspiration biopsy, surgical excisions were practiced, superficial parotidectomy was performed. Histopathological examination showed parotid lipoma. Conclusion: Lipomas are common soft tissue neoplasms but found very rarely in the parotid gland, and so, are after not considered in the initial differential diagnosis of parotid gland tumor

  18. Parotid gland as an initial site of metastasis

    International Nuclear Information System (INIS)

    Borg, Martin F.

    2004-01-01

    The parotid gland is an uncommon site of metastasis from carcinomas arising outside the head and neck region. Involvement of the parotid gland as an initial site of metastasis or presentation is rare. The present case report is the first, to our knowledge, to describe the management and outcome of an elderly man whose first presentation of an asymptomatic squamous cell carcinoma of the lung was that of a rapidly growing fungating left parotid mass Copyright (2004) Blackwell Publishing Asia Pty Ltd

  19. A STUDY ON PAROTID SWELLINGS

    Directory of Open Access Journals (Sweden)

    Alli Muthiah

    2017-03-01

    Full Text Available BACKGROUND Swellings of the parotid gland are of special interest to a surgeon’s keen eye. These lesions are not only involved in diseases isolated to the parotid, but can also present as a part of a generalised systemic disorder, medical or surgical. For a surgeon, the interests lie in the probable origin of the swelling, its involvement of the facial nerve, the variability in behaviour, regarding the operability criteria and its postoperative complications. 1 A comprehensive knowledge of the anatomy of the parotid and the prediction of the swelling behaviour can help not only in the diagnosis, but also in ensuring an apt management of the lesion and the patient. 2 This cohort study was conducted to analyse the following in our institution. The incidence of various parotid swellings to discuss accuracy of FNAC in comparison to the histopathological reports. The various surgical modalities of treatment of parotid swellings applied. MATERIALS AND METHODS The cohort study, which included 45 patients was conducted at Kilpauk Medical College Hospital and Government Royapettah Hospital from September 2010 to October 2012. Data was collected from the patients after obtaining an informed consent. The demographic details of the patients and history of their swelling was taken. The patients were examined and basic investigations performed. Details regarding the FNAC report, surgical and nonsurgical management were noted. Postoperative complications were documented. The final histopathological report was analysed and compared with the FNAC report. RESULTS Parotid lesions are commonest cases in our study. Benign tumours are more common than malignant lesions. This study found to correlate with world statistics. Investigations, clinical findings and treatment correlate well with world statistical records. CONCLUSION The analysis of the data of the study conducted at our institution provided us with the following results- Parotid lesions comprised of the

  20. Perfusion imaging of parotid gland tumours: usefulness of arterial spin labeling for differentiating Warthin's tumours

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroki; Watanabe, Haruo [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Kanematsu, Masayuki [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Gifu University Hospital, High-level Imaging Diagnosis Center, Gifu (Japan); Kajita, Kimihiro [Gifu University Hospital, High-level Imaging Diagnosis Center, Gifu (Japan); Mizuta, Keisuke; Aoki, Mitsuhiro [Gifu University School of Medicine, Department of Otolaryngology, Gifu (Japan); Okuaki, Tomoyuki [Philips Healthcare, Tokyo (Japan)

    2015-11-15

    To assess prospectively the efficacy of arterial spin labelling (ASL) against conventional and diffusion-weighted (DW) MR imaging for differentiating parotid gland tumours. We included 10 pleomorphic adenomas, 12 Warthin's tumours, and nine malignant tumours of the parotid glands. Only tumours larger than 10 mm were included in this study. All parotid gland tumours underwent T1-weighted, T2-weighted, DW, and ASL imaging. Tumour-to-parotid gland signal intensity ratios (SIRs) and apparent diffusion coefficients (ADCs) of solid components were correlated with these pathologies. SIRs on T2-weighted images and ADCs were higher in pleomorphic adenomas than in Warthin's tumours (p <.01) and malignant tumours (p <.01). SIRs on ASL were higher in Warthin's tumours than in pleomorphic adenomas (p <.01) and malignant tumours (p <.05). Az value of SIRs on ASL for differentiating Warthin's tumours from the other pathologies was 0.982. The sensitivity, specificity, and accuracy of SIRs on ASL for the diagnosis of Warthin's tumours at an optimal SIR threshold of over 8.70 were 91.7 %, 94.7 %, and 93.5 %, respectively. ASL with SIR measurements could non-invasively evaluate tumour blood flow of parotid gland tumours and differentiate Warthin's tumours from pleomorphic adenomas and malignant tumours. (orig.)

  1. Effects of different tastants on parotid saliva flow and composition

    NARCIS (Netherlands)

    Neyraud, E.; Heinzerling, C.I.; Bult, J.H.F.; Mesmin, C.; Dransfield, E.

    2009-01-01

    Saliva from parotid glands plays a role in taste perception. Parotid saliva is also stimulated by tastants. The aim of this work is to investigate the effects of different tastants on the parotid salivary response in six subjects. Five tastants were given in different concentrations in solution and

  2. assessment Of the effect Of low Level Laser Therapy on Parotid glands of gamma Irradiated Rats

    International Nuclear Information System (INIS)

    Ahmed, S.F.

    2013-01-01

    Gamma radiation-induced salivary gland dysfunction has a major deleterious effect on oral health. Aim: This study was carried out to evaluate the possible effect of low level laser therapy (LLLT) on radiation induced oxidative stress in rats’ salivary glands. Material and Methods: Sixty four male Albino rats were divided into two groups. One group where the left parotid gland was exposed to 3 sessions of LLL, then rats were subjected to 3 sessions of whole body gamma-radiation. In the other group, rats were subjected to 3 sessions of gamma-radiation; each was followed by a session of LLL to the left parotid gland. The right gland of both groups was used as irradiated control. Parotid glands were collected 1 day, 3 days, 1 week and 2 weeks after the end of treatment and were subjected to histological examination and immunohistochemical analysis. Results: The parotid gland of both laser groups showed less intra cytoplasmic vacuolisation, slight alteration of acinar architecture and almost even size nuclei as compared to the irradiated gland. LLL either before or parallel to gamma-irradiation was effective in increasing cell proliferation on the third and seventh day, respectively as compared to the gamma irradiated group (P<0.05). Statistically, results revealed significant decrease in optical density of caspase 3 activity in the lased groups on the first week as compared to the control. Conclusion: LLLT attenuates the harmful effect of gamma irradiation on the parotid glands of the rats. Also, it improves gland regeneration through modulation of cell proliferation and apoptosis inflammation

  3. [Sialoendoscopy-assisted sialolithectomy for large parotid stones].

    Science.gov (United States)

    Zhao, Jian; Zhang, Lei; Liu, Deng-gao; Zhang, Zu-yan; Yu, Guang-yan

    2014-02-18

    To explore the clinical application of endoscope-assisted operative retrieval of large parotid stones as a minimally invasive alternative. From January 2010 to April 2013, 6 patients (male: 5, female: 1, age from 30-62 years, and median age: 49.5 years)suffering from recurred swelling of parotid gland due to sialoliths were treated by endoscope-assisted parotid surgery in Peking University School and Hospital of Stomatology. All of the patients underwent clinical, ultrasonographic and cone-beam CT (CBCT) examinations to get the detailed information of the number, location and size of stones, which was recorded in the medical records. endoscope-assisted parotid surgery was performed under general anesthesia in all the 6 cases after the failure of basket or forcep retrieval firstly. During the operation, sialoendoscope was used to locate the stone exactly and then the calculus was exposed through a pre-auricular approach and released by incising the duct. The postoperative complications were recorded and observed during the follow-up periods. Preoperative radiological examinations showed that all of the sialoliths were near the hilum of parotid gland ducts in the 6 cases, which were 5-9 mm in diameter. All of the stones were removed successfully by endoscope-assisted operative retrieval. The incisions healed smoothly in all the 6 cases. There were no cases of facial nerve weakness, infection or salivary fistula. After a mean follow-up of 19 months (ranging from 6-36 months), 5 patients remained asymptomatic and 1 patient had mild obstructed or infective symptoms. The final results were satisfied. It is suggested that endoscope-assisted operative retrieval is a viable minimally invasive alternative to remove the large or recalcitrant parotid stones with a high successful rate and low complications.

  4. The radioimmunoassay of biologically active compounds in parotid fluid and plasma

    International Nuclear Information System (INIS)

    Walker, R.F.; Read, G.F.; Riad-Fahmy, D.

    1977-01-01

    The potential value of parotid fluid estimations of clomipramine, d-norgestrel, and cortisol have been evaluated for assessment of clinical status and patient compliance. Excellent agreement (r > 0.9) was observed when parotid fluid samples were assayed with and without chromatographic purification. Clomipramine levels following oral dosage (150mg) rose steadily to a maximum in plasma but showed wide fluctuations in parotid fluid. Following an oral dose of d-norgestrel(0.3mg), parotid fluid levels rose steadily to a maximum but plasma response was biphasic making correlation impossible. The sensitivity and high throughput of the d-norgestrel methodology suggests its use in evaluating patient compliance in large scale fertility control programmes. Changes in circulating cortisol concentrations were rapidly and accurately reflected in parotid fluid in normal volunteers. Parotid fluid cortisol showed a market diurnal rythm, suppression to low levels after dexamethasone, and elevation following Synacthen. Low levels after Synacthen stimulation in a patient with secondary adrenal atrophy and constant high levels in Cushingoid patients indicate that parotid fluid cortisol levels could be used for accurate adrenocortical evaluation. The value in rapid screening procedures is stressed since the assay can be performed directly on only 10μl of parotid fluid. (orig./AJ) [de

  5. Implementation of intensity modulation with dynamic multileaf collimation

    Energy Technology Data Exchange (ETDEWEB)

    Wong, J W; Yu, C; Jaffray, D [William Beaumont Hospital, Royal Oak, MI (United States)

    1995-12-01

    The computer-controlled multileaf collimator (MLC) marks one of the most important advances in radiation therapy. The device efficiently replaces manual blocking to shape fields and can be used to modulate beam intensity. The results of a research programme at William Beaumont Hospital, aimed at bringing dynamic intensity modulation into clinical use, are discussed.

  6. Diabetes insípida post-parotiditis

    OpenAIRE

    Pila Pérez, Rafael; Rivero Sánchez, Miguel; Peralta Ventura, Ricardo; Carbonell Perdomo, Diego; Pila Peláez, Rafael; Guerra Rodríguez, Carmen

    2001-01-01

    Se describe un caso de diabetes insípida post parotiditis, entidad sumamente rara en nuestro medio. Se destaca el diagnóstico y la terapéutica de esta entidad, así como la causa etiológico y forma de presentación. A case of diabetes insipidus post-parotiditis is described entity totally rare in our midicu. Diagnostics and therapeutics are stressed a well as the ethiologic antecedent and way of presentation.

  7. Comparative analysis of 60Co intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Fox, Christopher; Romeijn, H Edwin; Lynch, Bart; Dempsey, James F; Men, Chunhua; Aleman, Dionne M

    2008-01-01

    In this study, we perform a scientific comparative analysis of using 60 Co beams in intensity-modulated radiation therapy (IMRT). In particular, we evaluate the treatment plan quality obtained with (i) 6 MV, 18 MV and 60 Co IMRT; (ii) different numbers of static multileaf collimator (MLC) delivered 60 Co beams and (iii) a helical tomotherapy 60 Co beam geometry. We employ a convex fluence map optimization (FMO) model, which allows for the comparison of plan quality between different beam energies and configurations for a given case. A total of 25 clinical patient cases that each contain volumetric CT studies, primary and secondary delineated targets, and contoured structures were studied: 5 head-and-neck (H and N), 5 prostate, 5 central nervous system (CNS), 5 breast and 5 lung cases. The DICOM plan data were anonymized and exported to the University of Florida optimized radiation therapy (UFORT) treatment planning system. The FMO problem was solved for each case for 5-71 equidistant beams as well as a helical geometry for H and N, prostate, CNS and lung cases, and for 3-7 equidistant beams in the upper hemisphere for breast cases, all with 6 MV, 18 MV and 60 Co dose models. In all cases, 95% of the target volumes received at least the prescribed dose with clinical sparing criteria for critical organs being met for all structures that were not wholly or partially contained within the target volume. Improvements in critical organ sparing were found with an increasing number of equidistant 60 Co beams, yet were marginal above 9 beams for H and N, prostate, CNS and lung. Breast cases produced similar plans for 3-7 beams. A helical 60 Co beam geometry achieved similar plan quality as static plans with 11 equidistant 60 Co beams. Furthermore, 18 MV plans were initially found not to provide the same target coverage as 6 MV and 60 Co plans; however, adjusting the trade-offs in the optimization model allowed equivalent target coverage for 18 MV. For plans with comparable

  8. Ultrasound-guided needle aspiration of parotid abscess

    Directory of Open Access Journals (Sweden)

    André Takahashi

    2012-01-01

    Full Text Available Ultrasound (US has been used as a tool for parotid abscess diagnosis and treatment. The present article aimed to report a case of 72-year-old woman with parotid abscess treated by US-guided needle aspiration and conventional surgical drainage. Along with the clinical report, indications, advantages, and limitations of the method are discussed.

  9. Contemporary Management of Benign and Malignant Parotid Tumors.

    Science.gov (United States)

    Thielker, Jovanna; Grosheva, Maria; Ihrler, Stephan; Wittig, Andrea; Guntinas-Lichius, Orlando

    2018-01-01

    To report the standard of care, interesting new findings and controversies about the treatment of parotid tumors. Relevant and actual studies were searched in PubMed and reviewed for diagnostics, treatment and outcome of both benign and malignant tumors. Prospective trials are lacking due to rarity of the disease and high variety of tumor subtypes. The establishment of reliable non-invasive diagnostics tools for the differentiation between benign and malignant tumors is desirable. Prospective studies clarifying the association between different surgical techniques for benign parotid tumors and morbidity are needed. The role of adjuvant or definitive radiotherapy in securing loco-regional control and improving survival in malignant disease is established. Prospective clinical trials addressing the role of chemotherapy/molecular targeted therapy for parotid cancer are needed. An international consensus on the classification of parotid surgery techniques would facilitate the comparison of different trials. Such efforts should lead into a clinical guideline.

  10. Automated Segmentation of the Parotid Gland Based on Atlas Registration and Machine Learning: A Longitudinal MRI Study in Head-and-Neck Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiaofeng [Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Wu, Ning; Cheng, Guanghui [Radiation Oncology, Jilin University, Chuangchun, Jilin (China); Zhou, Zhengyang [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing (China); Yu, David S.; Beitler, Jonathan J.; Curran, Walter J. [Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Liu, Tian, E-mail: tliu34@emory.edu [Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia (United States)

    2014-12-01

    Purpose: To develop an automated magnetic resonance imaging (MRI) parotid segmentation method to monitor radiation-induced parotid gland changes in patients after head and neck radiation therapy (RT). Methods and Materials: The proposed method combines the atlas registration method, which captures the global variation of anatomy, with a machine learning technology, which captures the local statistical features, to automatically segment the parotid glands from the MRIs. The segmentation method consists of 3 major steps. First, an atlas (pre-RT MRI and manually contoured parotid gland mask) is built for each patient. A hybrid deformable image registration is used to map the pre-RT MRI to the post-RT MRI, and the transformation is applied to the pre-RT parotid volume. Second, the kernel support vector machine (SVM) is trained with the subject-specific atlas pair consisting of multiple features (intensity, gradient, and others) from the aligned pre-RT MRI and the transformed parotid volume. Third, the well-trained kernel SVM is used to differentiate the parotid from surrounding tissues in the post-RT MRIs by statistically matching multiple texture features. A longitudinal study of 15 patients undergoing head and neck RT was conducted: baseline MRI was acquired prior to RT, and the post-RT MRIs were acquired at 3-, 6-, and 12-month follow-up examinations. The resulting segmentations were compared with the physicians' manual contours. Results: Successful parotid segmentation was achieved for all 15 patients (42 post-RT MRIs). The average percentage of volume differences between the automated segmentations and those of the physicians' manual contours were 7.98% for the left parotid and 8.12% for the right parotid. The average volume overlap was 91.1% ± 1.6% for the left parotid and 90.5% ± 2.4% for the right parotid. The parotid gland volume reduction at follow-up was 25% at 3 months, 27% at 6 months, and 16% at 12 months. Conclusions: We have validated

  11. Cardiac dose sparing and avoidance techniques in breast cancer radiotherapy

    International Nuclear Information System (INIS)

    Shah, Chirag; Badiyan, Shahed; Berry, Sameer; Khan, Atif J.; Goyal, Sharad; Schulte, Kevin; Nanavati, Anish; Lynch, Melanie; Vicini, Frank A.

    2014-01-01

    Breast cancer radiotherapy represents an essential component in the overall management of both early stage and locally advanced breast cancer. As the number of breast cancer survivors has increased, chronic sequelae of breast cancer radiotherapy become more important. While recently published data suggest a potential for an increase in cardiac events with radiotherapy, these studies do not consider the impact of newer radiotherapy techniques commonly utilized. Therefore, the purpose of this review is to evaluate cardiac dose sparing techniques in breast cancer radiotherapy. Current options for cardiac protection/avoidance include (1) maneuvers that displace the heart from the field such as coordinating the breathing cycle or through prone patient positioning, (2) technological advances such as intensity modulated radiation therapy (IMRT) or proton beam therapy (PBT), and (3) techniques that treat a smaller volume around the lumpectomy cavity such as accelerated partial breast irradiation (APBI), or intraoperative radiotherapy (IORT). While these techniques have shown promise dosimetrically, limited data on late cardiac events exist due to the difficulties of long-term follow up. Future studies are required to validate the efficacy of cardiac dose sparing techniques and may use surrogates for cardiac events such as biomarkers or perfusion imaging

  12. A RARE CASE OF PAROTID CYST

    Directory of Open Access Journals (Sweden)

    Rambabu

    2015-09-01

    Full Text Available A 28 years old male presented with a case of painless soft fluctuant swelling of right parotid gland is reported to our hospital. The lesion was found to be a cystic lesion through the pre - operative examinations and investigations. The cyst was completely excised, taking care not to injure the lower division of the facial nerve. Po st recovery was uneventful with no defect of the facial nerve functions. The histologic picture confirmed that the cyst was lymphoepithelial cyst which is so called “branchial cyst”. Through the literature reviews of parotid lymphoepit h elial cyst the discu ssions on prevalence, origin, diagnosis, histological finding, investigation and the modes of treatment are made. The ultra sound was found to be valuable in the pre - operative evaluation of the parotid swelling furthermore it is non - invasive, harmless, pai nless and relatively quick

  13. Interventional sialendoscopy for parotid ductal calculi: our preliminary experience.

    Science.gov (United States)

    Singh, P P; Gupta, Neelima; Goyal, Arun; Tomar, Sanjeev

    2012-09-01

    With this article we present our initial experience with interventional sialendoscopy of the parotid duct for the parotid calculi. We carried out a prospective study of patients of parotid calculi in a tertiary referral centre. Diagnostic and interventional sialendoscopy was performed in five cases of parotid calculi. The outcome was classified on the basis of clearance of the lumen of the duct and resolution of symptoms. Diagnostic sialendoscopy was able to diagnose the calculus in all cases. Interventional sialendoscopy was done under general anesthesia in all cases and calculus was successfully removed. The average size of sialolith was 8.2 mm. No complications occurred in any of the cases. Check sialendoscopy was done in all cases after a minimum follow up of 6 months, which showed the duct lumen to be free of stone with no stricture of the duct. Sialendoscopy is an optimal technique for removal of intraductal parotid calculi and avoids removal of the gland. In our series there was no associated morbidity and complication.

  14. Longitudinal density modulation and energy conversion in intense beams

    International Nuclear Information System (INIS)

    Harris, J. R.; Neumann, J. G.; Tian, K.; O'Shea, P. G.

    2007-01-01

    Density modulation of charged particle beams may occur as a consequence of deliberate action, or may occur inadvertently because of imperfections in the particle source or acceleration method. In the case of intense beams, where space charge and external focusing govern the beam dynamics, density modulation may, under some circumstances, be converted to velocity modulation, with a corresponding conversion of potential energy to kinetic energy. Whether this will occur depends on the properties of the beam and the initial modulation. This paper describes the evolution of discrete and continuous density modulations on intense beams and discusses three recent experiments related to the dynamics of density-modulated electron beams

  15. New models of experimental parotitis and parotid gland distension in rats.

    Science.gov (United States)

    Okada-Ogawa, Akiko; Shinoda, Masamichi; Honda, Kuniya; Iwata, Koichi

    2012-01-01

    A significant reduction of the escape threshold to mechanical stimulation of the lateral facial skin was observed bilaterally at days 2 and 3 after unilateral complete Freund's adjuvant (CFA) administration into parotid gland. A slight reduction of mechanical escape threshold was also observed in rats with saline administration. The parotid gland inflammation was verified and quantified by measuring the tissue Evans' blue dye extravasation. The Evans' blue concentration in the parotid gland tissues was significantly greater in the CFA-injected rats than that of the saline-injected rats at 72 h after treatment. On day 10 after CFA administration into the parotid gland, the Evans' blue concentration was recovered to the control level. The administration of capsaicin into the parotid gland did not alter neuronal activities in the transition zone between the trigeminal spinal subnucleus interpolaris and caudalis (Vi/Vc). In contrast, capsaicin administration induced significant increases in the receptive field size and mechanical and cold responses of neurons located in superficial laminae of the C1/C2. The subgroup of C1/C2 neurons responded to mechanical distension of the parotid gland, whereas no Vi/Vc neurons responded to parotid distension.

  16. Is volumetric modulated arc therapy with constant dose rate a valid option in radiation therapy for head and neck cancer patients?

    Science.gov (United States)

    Didona, Annamaria; Lancellotta, Valentina; Zucchetti, Claudio; Panizza, Bianca Moira; Frattegiani, Alessandro; Iacco, Martina; Di Pilato, Anna Concetta; Saldi, Simonetta; Aristei, Cynthia

    2018-01-01

    Intensity-modulated radiotherapy (IMRT) improves dose distribution in head and neck (HN) radiation therapy. Volumetric-modulated arc therapy (VMAT), a new form of IMRT, delivers radiation in single or multiple arcs, varying dose rates (VDR-VMAT) and gantry speeds, has gained considerable attention. Constant dose rate VMAT (CDR-VMAT) associated with a fixed gantry speed does not require a dedicated linear accelerator like VDR-VMAT. The present study explored the feasibility, efficiency and delivery accuracy of CDR-VMAT, by comparing it with IMRT and VDR-VMAT in treatment planning for HN cancer. Step and shoot IMRT (SS-IMRT), CDR-VMAT and VDR-VMAT plans were created for 15 HN cancer patients and were generated by Pinnacle 3 TPS (v 9.8) using 6 MV photon energy. Three PTVs were defined to receive respectively prescribed doses of 66 Gy, 60 Gy and 54 Gy, in 30 fractions. Organs at risk (OARs) included the mandible, spinal cord, brain stem, parotids, salivary glands, esophagus, larynx and thyroid. SS-IMRT plans were based on 7 co-planar beams at fixed gantry angles. CDR-VMAT and VDR-VMAT plans, generated by the SmartArc module, used a 2-arc technique: one clockwise from 182° to 178° and the other one anti-clockwise from 178° to 182°. Comparison parameters included dose distribution to PTVs ( D mean , D 2% , D 50% , D 95% , D 98% and Homogeneity Index), maximum or mean doses to OARs, specific dose-volume data, the monitor units and treatment delivery times. Compared with SS-IMRT, CDR-VMAT significantly reduced the maximum doses to PTV1 and PTV2 and significantly improved all PTV3 parameters, except D 98% and D 95% . It significantly spared parotid and submandibular glands and was associated with a lower D mean to the larynx. Compared with VDR-VMAT, CDR-VMAT was linked to a significantly better D mean , to the PTV3 but results were worse for the parotids, left submandibular gland, esophagus and mandible. Furthermore, the D mean to the larynx was also worse

  17. Parotid Abscess with Involvement of Facial Nerve Branches.

    Science.gov (United States)

    Ozkan, Adile; Ors, Ceyda Hayretdag; Kosar, Sule; Ozisik Karaman, Handan Isin

    2015-08-01

    Facial nerve paresis is only rarely seen with benign diseases of the parotid gland. A 22-year male had muscle loss in the preauricular region of the right side of his face that extended towards the mandibular angle for the last 6 months. The neurological examination did not reveal any pathology other than right preauricular region muscle atrophy that was limited by the mandibular angle. The Electroneuronography (EnoG) provided a ratio of 55.38%, compared the affected side to left side. Ultrasonography of the defined region showed two mass lesions 13.5 x 7 mm and 10 x 5 mm in size in the anteromedial section of the right parotid gland that were close to each other, without internal calcific foci, and heterogenous hyperechogenic structure without internal vascularization. Fine needle aspiration obtained many polymorphonuclear leukocytes, cell debris, a few mononuclear inflammatory cells and many crystalloid structures. The lesion was diagnosed as a parotid abscess. Antibiotic treatment was started for the parotid gland abscess.

  18. Self-induced parapharyngeal and parotid emphysema: A case of pneumoparotitis

    Directory of Open Access Journals (Sweden)

    Javier González Lagunas

    2017-12-01

    Full Text Available Swelling of the parotid suggests pathological change. Enlargement of the parotid gland may result from infections, duct obstruction, benign or malignant tumors, allergies, autoimmune or systemic disease syndromes or lymphoproliferative diseases. Acute swelling is typically associated with viral infection or recurrent chronic parotitis. A rare cause of acute swelling is insufflation of air from the mouth via Stensen’s duct into the parotid region. We report a case of recurrent self-induced chronic pneumoparotitis with parapharyngeal extension in a teenager. Pneumoparotitis is rare and is often misdiagnosed and mistreated. Patients typically present with unilateral or bilateral painless swelling and tenderness in the parotid region. Imaging, including computer tomography scans, shows air within the parotid system that extends into the neighboring areas in cases of rupture of the parotid fascia. Salivary gland enlargement resolves spontaneously over 1–3 days. Some authors recommend anti-inflammatory drugs and prophylactic antibiotics to avoid superinfection. Several surgical treatments have been suggested for chronic and recurrent pneumoparotid. However, the primary challenge is to educate the patient to prevent an increase in intraoral pressure. Keywords: Pneumoparotitis, Pneumoparotiditis, Teenager, Head-and-neck emphysema

  19. Intensity modulated tangential beam irradiation of the intact breast

    International Nuclear Information System (INIS)

    Hong, L.; Hunt, M.; Chui, C.; Forster, K.; Lee, H.; Lutz, W.; Yahalom, J.; Kutcher, G.J.; McCormick, B.

    1997-01-01

    Purpose/Objective: The purpose of this study was to evaluate the potential benefits of intensity modulated tangential beams in the irradiation of the intact breast. The primary goal was to develop an intensity modulated treatment which would substantially decrease the dose to coronary arteries, lung and contralateral breast while still using a standard tangential beam arrangement. Improved target dose homogeneity, within the limits imposed by opposed fields, was also desired. Since a major goal of the study was the development of a technique which was practical for use on a large population of patients, the design of 'standard' intensity profiles analogous in function to conventional wedges was also investigated. Materials and Methods: Three dimensional treatment planning was performed using both conventional and intensity modulated tangential beams. Plans were developed for both the right and left breast for a range of patient sizes and shapes. For each patient, PTV, lung, heart, origin and peripheral branches of the coronary artery, and contralateral breast were contoured. Optimum tangential beam direction and shape were designed using Beams-Eye-View display and then used for both the conventional and intensity modulated plans. For the conventional plan, the optimum wedge combination and beam weighting were chosen based on the dose distribution in a single transverse plane through the field center. Intensity modulated plans were designed using an algorithm which allows the user to specify the prescribed, maximum and minimum acceptable doses and dose volume constraints for each organ of interest. Plans were compared using multiple dose distributions and DVHs. Results: Significant improvements in the doses to critical structures were achieved using the intensity modulated plan. Coronary artery dose decreased substantially for patients treated to the left breast. Ipsilateral lung and contralateral breast doses decreased for all patients. For one patient treated to

  20. CT findings of tuberculous lymphadenifis in parotid gland

    International Nuclear Information System (INIS)

    Wang Changfu; Wang Binjie; Zhang Heping; Jin Haiying; Nie Peng; Chang Liang; Wei Haigang; Zou Ling

    2008-01-01

    Objective: To analyze the CT findings of tuberculous lymphadenitis in parotid gland, so as to improve the diagnostic accuracy of tuberculosis of parotid gland. Methods: Nine cases with tuberculous lymphadenitis in parotid gland confirmed by surgical pathology and acid-fast bacilli after preoperative spiral CT plain scan and two phases dynamic enhancement scan were retrospectively analyzed. Imaging findings of CT were reviewed and compared with surgical pathology. Results: Seven of the 9 cases of tuberculosis of the parotid gland occurred in the left side, and 2 in the right side, and superficial lobe involvement occurred in 8 cases and deep lobe in 1 case. The lesion was classified as tumour type (8 cases) and infiltration type (1 case). In turnout type, the number of lesion was from 1 to 4, and the size was from 2.7 to 5.3 cm in diameter. One case of infiltration type measured 3.4 cm in diameter. On CT plain scan, the lesions showed homogeneous slight high-density with regular edge in 5 cases and irregular low-density in 4 cases, and 2 of them with partly blurred edge. On CT enhanced scan, uniform moderate enhancement was seen in 3 cases, circular enhancement in 4 cases, inhomogeneous enhancement in 1 case, and lace-like enhancement in 1 case. Local infiltration occurred in 6 cases. Lymphadenovarix in the same side of lesion occurred in 2 cases. Conclusion: CT findings of tuberculous lymphadenitis in parotid gland present diversification, which correlate well with pathological changes. Understanding of characteristic CT findings of tuberculous lymphadenitis in parotid gland is helpful for differential diagnosis, but final diagnosis still depends on pathology and acid-fast bacilli. (authors)

  1. Parotid Duct Repair with Intubation Tube: Technical Note

    Science.gov (United States)

    Öztürk, Muhammed Beşir; Barutca, Seda Asrufoğlu; Keskin, Elif Seda; Atik, Bekir

    2017-01-01

    The parotid duct can be damaged in traumatic injuries and surgical interventions. Early diagnosis and treatment of a duct injury is of great importance because complications such as sialocele and salivary gland fistula may develop if the duct is not surgically repaired. We think the cuff of an intubation tube is an ideal material in parotid duct repair, because of its technical characteristics, easiness of availability, and low-cost. In this paper, we described the use of the cuff cannula of an intubation tube for the diagnosis and treatment of parotid duct laceration, as a low-cost and easy to access material readily available in every operating room. PMID:28713751

  2. Modeling of Salivary Production Recovery After Radiotherapy Using Mixed Models: Determination of Optimal Dose Constraint for IMRT Planning and Construction of Convenient Tools to Predict Salivary Function

    International Nuclear Information System (INIS)

    Ortholan, Cecile; Chamorey, Emmanuel Phar; Benezery, Karen; Thariat, Juliette; Dassonville, Olivier; Poissonnet, Gilles; Bozec, Alexandre; Follana, Philippe; Peyrade, Frederique; Sudaka, Anne; Gerard, Jean Pierre; Bensadoun, Rene Jean

    2009-01-01

    Purpose: The mathematical relationship between the dose to the parotid glands and salivary gland production needs to be elucidated. This study, which included data from patients included in a French prospective study assessing the benefit of intensity-modulated radiotherapy (RT), sought to elaborate a convenient and original model of salivary recovery. Methods and Materials: Between January 2001 and December 2004, 44 patients were included (35 with oropharyngeal and 9 with nasopharyngeal cancer). Of the 44 patients, 24 were treated with intensity-modulated RT, 17 with three-dimensional conformal RT, and 2 with two-dimensional RT. Stimulated salivary production was collected for ≤24 months after RT. The data of salivary production, time of follow-up, and dose to parotid gland were modeled using a mixed model. Several models were developed to assess the best-fitting variable for the dose level to the parotid gland. Results: Models developed with the dose to the contralateral parotid fit the data slightly better than those with the dose to both parotids, suggesting that contralateral and ipsilateral parotid glands are not functionally equivalent even with the same dose level to the glands. The best predictive dose-value variable for salivary flow recovery was the volume of the contralateral parotid gland receiving >40 Gy. Conclusion: The results of this study show that the recommendation of a dose constraint for intensity-modulated RT planning should be established at the volume of the contralateral parotid gland receiving >40 Gy rather than the mean dose. For complete salivary production recovery after 24 months, the volume of the contralateral parotid gland receiving >40 Gy should be <33%. Our results permitted us to establish two convenient tools to predict the saliva production recovery function according to the dose received by the contralateral parotid gland

  3. Parotid gland tumours: a six years experience

    International Nuclear Information System (INIS)

    Malik, K.A.

    2006-01-01

    To find out the different types of Parotid tumours in out setup and their prevalence in different age groups. All patients admitted with Parotid swellings, irrespective of age and sex. The detailed data of the patients was collected and analyzed. A total of 27 patients, 15 males and 12 females, with ages ranging from 15 to 65 years were included in the study. Most of the patients were in the 31-50 years of age group. Pleomorphic adenoma was the commonest benign tumour with an incidence of 66.6%, while Mucoepidermoid Carcinoma with an incidence of 11.11% was the most common malignant tumour. Parotid gland is the principal site of salivary gland tumours. Males are affected more and Pleomorphic adenoma is the most common benign and Mucoepidermoid carcinoma the most common malignant tumour. (author)

  4. Cell phone use and parotid salivary gland alterations: no molecular evidence.

    Science.gov (United States)

    de Souza, Fabrício T A; Correia-Silva, Jeane F; Ferreira, Efigênia F; Siqueira, Elisa C; Duarte, Alessandra P; Gomez, Marcus Vinícius; Gomez, Ricardo S; Gomes, Carolina C

    2014-07-01

    The association between cell phone use and the development of parotid tumors is controversial. Because there is unequivocal evidence that the microenvironment is important for tumor formation, we investigated in the parotid glands whether cell phone use alters the expression of gene products related to cellular stress. We used the saliva produced by the parotid glands of 62 individuals to assess molecular alterations compatible with cellular stress, comparing the saliva from the gland exposed to cell phone radiation (ipsilateral) to the saliva from the opposite, unexposed parotid gland (contralateral) of each individual. We compared salivary flow, total protein concentration, p53, p21, reactive oxygen species (ROS), and salivary levels of glutathione (GSH), heat shock proteins 27 and 70, and IgA between the ipsilateral and contralateral parotids. No difference was found for any of these parameters, even when grouping individuals by period of cell phone use in years or by monthly average calls in minutes. We provide molecular evidence that the exposure of parotid glands to cell phone use does not alter parotid salivary flow, protein concentration, or levels of proteins of genes that are directly or indirectly affected by heat-induced cellular stress. ©2014 American Association for Cancer Research.

  5. Incidental benign parotid lesions on FDG-PET: prevalence and clinico-pathologic findings

    International Nuclear Information System (INIS)

    Lim, Il Han; Lee, Won Woo; Chung, Jin Haeng; Park, So Yeon; Kim, Sang Hee; Kim, Yu Kyeong; Kim, Sang Eun

    2007-01-01

    Incidental parotid lesions on F-18 FDG-PET can mimic distant metastasis of underlying malignancy. The prevalence and the clinico-pathologic findings of PET positive parotid lesions have not been known. We investigated how often incidental parotid lesions are found on clinical FDG-PET studies and what the clinico-pathologic characteristics of those parotid lesions are in the present study. We retrospectively reviewed 3,344 cases of FDG-PET which had been obtained in our hospital from May 2003 to Dec 2006. The indications of FDG-PET were: evaluation of known/suspected cancer (n = 3,212) or screening of cancer in healthy subjects (n = 132). Incidental parotid lesion on FDG-PET was defined as an un-expected FDG uptake in one of parotid glands which was not primary target lesion of current FDG/PET. FDG uptake was represented by maximum standardized uptake value (maxSUV). Final diagnosis was made by pathologic analysis or clinical follow-up assessment. Fifteen (0.45% = 15/3,344) incidental parotid lesions were found and they were all benign lesions. The maxSUV ranged from 1.7 to 8.6 (mean ± s.d. = 3.7 ± 1.9). Final diagnoses of the incidental parotid lesions were; Warthin's tumor (n = 2), pleomorphic adenoma (n = 1), other un-specified benign lesion (n 1), and benign lesions under bases of imaging studies (n = 3) and of clinical follow-up (n = 8). All of incidentally found parotid lesions in clinical FDG-PET studies were confirmed as benign lesions with prevalence of 0.45%. Close follow up using PET or CT might be a reasonable approach for determining the nature of incidentally found parotid lesions

  6. MR imaging of the parotid gland

    International Nuclear Information System (INIS)

    Vogl, T.; Dresel, S.; Lissner, J.; Grevers, G.; Riederer, A.

    1989-01-01

    In this study MR imaging combined with Gd-DTPA as a new effective diagnostic tool is compared with plain MR imaging. Seventy-two patients with lesions of the parotid gland were examined. In the author's patient group, they found 25 malignant tumors, 19 benign lesions, 20 Sjogren syndromes, and eight inflamed parotid glands. Axial and coronal images were acquired with long (TR = 1,600 msec, TE = 25/90 msec) and short (TR = 500 msec, TE = 25 msec) spin-echo sequences before and after Gd-DTPA

  7. Isolated Light Chain Amyloidosis Involving the Parotid Gland: A Case Report.

    Science.gov (United States)

    Gareb, Barzi; Perry, Michael; Tadrous, Paul Joseph

    2018-03-08

    Amyloidosis in the parotid gland is rare and is usually associated with systemic amyloidosis. Localized amyloidosis in the parotid gland is extremely rare. We present a case of localized light chain amyloidosis of the parotid gland without systemic involvement. A 70-year-old woman presented with an asymptomatic swelling of the right parotid region. The findings of a physical examination, hematologic and biochemical investigations, imaging, and cytology were inconclusive. The patient underwent an extracapsular dissection of the right parotid gland. Histologic analysis showed that the tissue of the right parotid gland mostly consisted of amyloid deposition. The amyloid stained with antibodies to lambda light chains. Additional investigations showed no systemic involvement. The patient is asymptomatic 5 months after surgery. Clinicians should be aware of the possibility of localized amyloid light chain amyloidosis in the parotid gland, especially if magnetic resonance imaging, computed tomography imaging, and ultrasound findings are inconclusive, and they should recognize, evaluate, and treat it accordingly. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. All rights reserved.

  8. Analysis of small-signal intensity modulation of semiconductor ...

    Indian Academy of Sciences (India)

    This paper demonstrates theoretical characterization of intensity modulation of semiconductor lasers (SL's). The study is based on a small-signal model to solve the laser rate equations taking into account suppression of optical gain. Analytical forms of the small-signal modulation response and modulation bandwidth are ...

  9. A dosimetric comparison of fan-beam intensity modulated radiotherapy with gamma knife stereotactic radiosurgery for treating intermediate intracranial lesions

    International Nuclear Information System (INIS)

    Ma Lijun; Xia Ping; Verhey, Lynn J.; Boyer, Arthur L.

    1999-01-01

    Purpose: To compare and evaluate treatment plans for the fan-beam intensity modulated radiotherapy and the Gamma Knife radiosurgery for treating medium-size intracranial lesions (range 4-25 cm 3 ). Methods and Materials: Treatment plans were developed for the Leksell Gamma Knife and a fan-beam inverse treatment planning system for intensity modulated radiotherapy. Treatment plan comparisons were carried out using dose-volume histogram (DVH), tissue-volume ratio (TVR), and maximum dose to the prescription dose (MDPD) ratio. The study was carried out for both simulated targets and clinical targets with irregular shapes and at different locations. Results: The MDPD ratio was significantly greater for the Gamma Knife plans than for the fan-beam IMRT plans. The Gamma Knife plans produced equivalent TVR values to the fan-beam IMRT plans. Based on the DVH comparison, the fan-beam IMRT delivered significantly more dose to the normal brain tissue than the Gamma Knife. The results of the comparison were found to be insensitive to the target locations. Conclusion: The Gamma Knife is better than the fan-beam IMRT in sparing normal brain tissue while producing equivalent tumor dose conformity for treating medium-size intracranial lesions. However, the target dose homogeneity is significantly better for the fan-beam IMRT than for the Gamma Knife

  10. SU-F-P-26: Study of Radiation Dose Evaluation for Organs at Risk Using MRI in Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Gong, G; Guo, Y; Yin, Y [Shandong Cancer Hospital and Institute, Jinan, Shandong (China)

    2016-06-15

    Purpose: To study the contour and dosimetric feature of organs at risk (OARs) applying magnetic resonance imaging (MRI) images in intensity modulated radiation therapy (IMRT) of nasopharyngeal carcinoma (NPC) compared to computed tomography (CT) images. Methods: 35 NPC patients was selected into this trail. CT simulation with non-contrast and contrast enhanced scan, MRI simulation with non-contrast and contrast enhanced T1, T2 and diffusion weighted imaging were achieved sequentially. And the OARs were contoured on the CT and MRI images after rigid registration respectively. 9 beams IMRT plan with equal division angle were designed for every patients, and the prescription dose for tumor target was set as 72Gy (2.4Gy/ fration). The boundary display, volume and dose-volume indices of each organ were compared between on MRI and CT images. Results: Compared to CT, MRI showed clearer boundary of brainstem, spinal cord, the deep lobe of Parotid gland and the optical nerve in canal. MRI images increase the volume of lens, optical nerve, while reducing the volume of eye slightly, and the maximum dose of lens, the mean dose of eyes and optical raised in different percentage, while there was no statistical differences were found. The left and right parotid volume on MRI increased by 7.07%, 8.13%, and the mean dose raised by 14.95% (4.01Gy), 18.76% (4.95Gy) with statistical significant difference (p<0.05). The brainstem volume reduced by 9.33% (p<0.05), and the dose of 0.1cm3 volume (D0.1cm3) reduced by mean 8.46% (4.32Gy), and D0.1cm3 of spinal cord increased by 1.5Gy on MRI. Conclusion: It is credible to evaluate the radiation dose of lens, eye and the spinal cord, while it should be necessary to evaluate the dose of brainstem, parotid and the optical nerve applying MRI images sometime, it will be more meaningful for these organs with high risk of radiation injury.

  11. Intensity-modulated radiation therapy.

    Science.gov (United States)

    Goffman, Thomas E; Glatstein, Eli

    2002-07-01

    Intensity-modulated radiation therapy (IMRT) is an increasingly popular technical means of tightly focusing the radiation dose around a cancer. As with stereotactic radiotherapy, IMRT uses multiple fields and angles to converge on the target. The potential for total dose escalation and for escalation of daily fraction size to the gross cancer is exciting. The excitement, however, has greatly overshadowed a range of radiobiological and clinical concerns.

  12. Comparative analysis of {sup 60}Co intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fox, Christopher [Sun Nuclear Corporation, 425-A Pineda Court, Melbourne, FL 32940 (United States); Romeijn, H Edwin; Lynch, Bart; Dempsey, James F [Department of Radiation Oncology, University of Florida, Gainesville, FL 32610-0385 (United States); Men, Chunhua [Department of Industrial and Systems Engineering, University of Florida, Gainesville, FL 32611-6595 (United States); Aleman, Dionne M [Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario (Canada)], E-mail: chrisfox@sunnuclear.com, E-mail: romeijn@ise.ufl.edu, E-mail: lynchb@ufl.edu, E-mail: chhmen@ufl.edu, E-mail: aleman@mie.utoronto.edu, E-mail: dempsey@ufl.edu

    2008-06-21

    In this study, we perform a scientific comparative analysis of using {sup 60}Co beams in intensity-modulated radiation therapy (IMRT). In particular, we evaluate the treatment plan quality obtained with (i) 6 MV, 18 MV and {sup 60}Co IMRT; (ii) different numbers of static multileaf collimator (MLC) delivered {sup 60}Co beams and (iii) a helical tomotherapy {sup 60}Co beam geometry. We employ a convex fluence map optimization (FMO) model, which allows for the comparison of plan quality between different beam energies and configurations for a given case. A total of 25 clinical patient cases that each contain volumetric CT studies, primary and secondary delineated targets, and contoured structures were studied: 5 head-and-neck (H and N), 5 prostate, 5 central nervous system (CNS), 5 breast and 5 lung cases. The DICOM plan data were anonymized and exported to the University of Florida optimized radiation therapy (UFORT) treatment planning system. The FMO problem was solved for each case for 5-71 equidistant beams as well as a helical geometry for H and N, prostate, CNS and lung cases, and for 3-7 equidistant beams in the upper hemisphere for breast cases, all with 6 MV, 18 MV and {sup 60}Co dose models. In all cases, 95% of the target volumes received at least the prescribed dose with clinical sparing criteria for critical organs being met for all structures that were not wholly or partially contained within the target volume. Improvements in critical organ sparing were found with an increasing number of equidistant {sup 60}Co beams, yet were marginal above 9 beams for H and N, prostate, CNS and lung. Breast cases produced similar plans for 3-7 beams. A helical {sup 60}Co beam geometry achieved similar plan quality as static plans with 11 equidistant {sup 60}Co beams. Furthermore, 18 MV plans were initially found not to provide the same target coverage as 6 MV and {sup 60}Co plans; however, adjusting the trade-offs in the optimization model allowed equivalent target

  13. Influence of Handheld Mobiles on Parotid: A Cohort Study

    Directory of Open Access Journals (Sweden)

    Gracelin E Ranjitha

    2017-01-01

    Full Text Available Introduction: Mobile phones generate heat and radiofrequency radiation. The parotid gland is one potential target, because mobile phones are pressed against the side of the face where the gland is located. Aims and Objectives: To compare the effect of mobile phone radiation on parotid gland volume, systolic velocity, salivary flow rate, and protein concentration between the dominant and the nondominant side of mobile phone usage among heavy mobile phone users. Materials and Methods: Ultrasonography of the superior lobe of parotid was performed bilaterally to measure gland volume. Systolic velocity of the external carotid artery in gland was calculated bilaterally using color Doppler imaging. Saliva flow rate was measured bilaterally with modified Schrimer strip. Carlson-Crittenden device was used to collect 0.5 ml saliva sample from the duct and biuret assay was done to determine the protein concentration. Settings and Design: A cohort study was conducted with 50 undergraduate students of a dental college based on the inclusion and exclusion criteria. Statistical Analysis Used: Pearson correlation test was used to correlate and compare changes in the parameters of parotid gland and analyzed to a significant level of 0.05. Results: The volume, systolic velocity of blood flow of the external carotid artery, the salivary flow rate, and protein concentration of the parotid gland were significantly more by 11.9, 18, 23, and 8%, respectively, on the dominant side than the nondominant side of mobile phone usage. Conclusion: The study emphasized that prolonged mobile phone usage causes biological changes in parotid gland.

  14. Replanning Criteria and Timing Definition for Parotid Protection-Based Adaptive Radiation Therapy in Nasopharyngeal Carcinoma

    Directory of Open Access Journals (Sweden)

    Wei-Rong Yao

    2015-01-01

    Full Text Available The goal of this study was to evaluate real-time volumetric and dosimetric changes of the parotid gland so as to determine replanning criteria and timing for parotid protection-based adaptive radiation therapy in nasopharyngeal carcinoma. Fifty NPC patients were treated with helical tomotherapy; volumetric and dosimetric (Dmean, V1, and D50 changes of the parotid gland at the 1st, 6th, 11th, 16th, 21st, 26th, 31st, and 33rd fractions were evaluated. The clinical parameters affecting these changes were studied by analyses of variance methods for repeated measures. Factors influencing the actual parotid dose were analyzed by a multivariate logistic regression model. The cut-off values predicting parotid overdose were developed from receiver operating characteristic curves and judged by combining them with a diagnostic test consistency check. The median absolute value and percentage of parotid volume reduction were 19.51 cm3 and 35%, respectively. The interweekly parotid volume varied significantly (p<0.05. The parotid Dmean, V1, and D50 increased by 22.13%, 39.42%, and 48.45%, respectively. The actual parotid dose increased by an average of 11.38% at the end of radiation therapy. Initial parotid volume, initial parotid Dmean, and weight loss rate are valuable indicators for parotid protection-based replanning.

  15. The effects of diabetes on the rat parotid gland

    International Nuclear Information System (INIS)

    Park, Chull Jea; Hwang, Eui Hwan; Lee, Sang Rae

    1996-01-01

    The purpose of the study was to observe microscopic change of salivary gland tissue, which is a cause of xerostomia in diabetic condition; for this target, the author injected streptozotocin 0.1 ml/100 gm b.w. on the rat, Sprague Dawley, to induce diabetes, and then observed microscopic changes in parotid gland tissue using light microscopy and electron microscopy. The results were as follows: 1. Parotid gland tissue of the diabetic rat was atrophied or degenerated in lapse of experimental time, but began to re pair from 14 days alter diabetic induction. 2. In the basal lamina of the vessel of parotid gland tissue in the diabetic rat, lamina lucida was discontinued and la mina densa was increased in thickness, but the number of capillary was gradually increased and dilated. 3. In acinic and intercalated ductal cells of parotid gland in the diabetic rat, changes of mitochondria, RER, secretor y granule, free ribosome were prominent. In conclusion, the present study demonstrated that degenerative changes of the parotid gland tissue were due to not completely thickening of the basal lamina of vessels, but many other causal factors, because thickness of the basal lamina of vessels was not related with degenerative changes.

  16. [Recurrent chronic parotiditis in childhood: An update of the literature].

    Science.gov (United States)

    Donoso-Hofer, Francisca; Gutiérrez Díaz, Rodrigo; Ortiz Cárdenas, Rodrigo; Osorio Herrera, Gustavo; Landaeta Mendoza, Mirtha

    2017-01-01

    Recurrent childhood chronic parotiditis (RCCP) is a relevant pathology. Its diagnosis is mainly clinical, but it relies on imaging tests. The current treatment approach is diverse. The aim of this article is to update the clinical features, complementary tests, etiopathogenic models and therapeutic protocols of this disease. A bibliographic search was performed in PUBMED using the free terms and MESH terms: RCCP, recurrent parotiditis, chronic parotiditis and parotiditis. The filters used were human patients, up to 18 years old, with abstract. In SCIELO the free terms included were Parotiditis and chronic. Articles published in English, Spanish or Portuguese until 2017 were included. In PUBMED 119 articles were found and 44 were included. The exclusion of the remaining articles was due to language, access to the article or absence of relationship between the article and the proposed revision. In SCIELO 6 articles were found 6 of which 5 were selected. The multidisciplinary asses of patients with RCCP is considered the appropriate treatment. Its diagnosis is clinical but it relies on imaging tests, such as echography and sialography. The current treatment approach is conservative, and the best available evidence supports the use of sialendoscopy with irrigation and administration of antibiotics and/or corticosteroids via the parotid duct. However, there would be proper results with intraglandular lavage with physiological solutions without the need for a sialendoscope.

  17. Dysphagia in head and neck cancer patients following intensity modulated radiotherapy (IMRT)

    International Nuclear Information System (INIS)

    Peponi, Evangelia; Glanzmann, Christoph; Willi, Bettina; Huber, Gerhard; Studer, Gabriela

    2011-01-01

    To evaluate the objective and subjective long term swallowing function, and to relate dysphagia to the radiation dose delivered to the critical anatomical structures in head and neck cancer patients treated with intensity modulated radiation therapy (IMRT, +/- chemotherapy), using a midline protection contour (below hyoid, ~level of vertebra 2/3). 82 patients with stage III/IV squamous cell carcinoma of the larynx, oropharynx, or hypopharynx, who underwent successful definitive (n = 63, mean dose 68.9Gy) or postoperative (n = 19, mean dose 64.2Gy) simultaneous integrated boost (SIB) -IMRT either alone or in combination with chemotherapy (85%) with curative intent between January 2002 and November 2005, were evaluated retrospectively. 13/63 definitively irradiated patients (21%) presented with a total gross tumor volume (tGTV) >70cc (82-173cc; mean 106cc). In all patients, a laryngo-pharyngeal midline sparing contour outside of the PTV was drawn. Dysphagia was graded according subjective patient-reported and objective observer-assessed instruments. All patients were re-assessed 12 months later. Dose distribution to the swallowing structures was calculated. At the re-assessment, 32-month mean post treatment follow-up (range 16-60), grade 3/4 objective toxicity was assessed in 10%. At the 32-month evaluation as well as at the last follow up assessment mean 50 months (16-85) post-treatment, persisting swallowing dysfunction grade 3 was subjectively and objectively observed in 1 patient (1%). The 5-year local control rate of the cohort was 75%; no medial marginal failures were observed. Our results show that sparing the swallowing structures by IMRT seems effective and relatively safe in terms of avoidance of persistent grade 3/4 late dysphagia and local disease control

  18. Intensity modulated radiation-therapy for preoperative posterior abdominal wall irradiation of retroperitoneal liposarcomas

    International Nuclear Information System (INIS)

    Bossi, Alberto; De Wever, Ivo; Van Limbergen, Erik; Vanstraelen, Bianca

    2007-01-01

    Purpose: Preoperative external-beam radiation therapy (preop RT) in the management of Retroperitoneal Liposarcomas (RPLS) typically involves the delivery of radiation to the entire tumor mass: yet this may not be necessary. The purpose of this study is to evaluate a new strategy of preop RT for RPLS in which the target volume is limited to the contact area between the tumoral mass and the posterior abdominal wall. Methods and Materials: Between June 2000 and Jan 2005, 18 patients with the diagnosis of RPLS have been treated following a pilot protocol of pre-op RT, 50 Gy in 25 fractions of 2 Gy/day. The Clinical Target Volume (CTV) has been limited to the posterior abdominal wall, region at higher risk for local relapse. A Three-Dimensional conformal (3D-CRT) and an Intensity Modulated (IMRT) plan were generated and compared; toxicity was reported following the National Cancer Institute (NCI) Common Terminology Criteria for Adverse Events v3.0. Results: All patients completed the planned treatment and the acute toxicity was tolerable: 2 patients experienced Grade 3 and 1 Grade 2 anorexia while 2 patients developed Grade 2 nausea. IMRT allows a better sparing of the ipsilateral and the contralateral kidney. All tumors were successfully resected without major complications. At a median follow-up of 27 months 2 patients developed a local relapse and 1 lung metastasis. Conclusions: Our strategy of preop RT is feasible and well tolerated: the rate of resectability is not compromised by limiting the preop CTV to the posterior abdominal wall and a better critical-structures sparing is obtained with IMRT

  19. A comparative dosimetric study of conventional, conformal and intensity-modulated radiotherapy in postoperative pelvic irradiation of cervical cancer

    International Nuclear Information System (INIS)

    Li Bin; An Jusheng; Wu Lingying; Huang Manni; Gao Juzhen; Xu Yingjie; Dai Jianrong

    2008-01-01

    Objective: To evaluate target-volume coverage and organ at risk (OAR) protection achieved with conventional radiotherapy (CRT), three dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy(IMRT) through dosimetric comparison in patients with cervical cancer after hysterectomy. Methods: The planning CT scans of 10 patients treated with pelvic radiation after hysterectomy for cervical cancer were used to generate CRT, 3DCRT and IMRT plans for this study. Clinical target volume(CTV) was contoured on the individual axial CT slices of every patient. The CTV was then uniformly expanded by 1.0 cm to create the planning target volume (PTV). The small bowel, rectum, bladder, bone marrow, ovaries, and femoral heads were outlined for the organ at risk (OAR) evaluation. The CRT, 3DCRT and IMRT plans were generated using commercial planning software. CRT plan was prescribed to deliver 45 Gy to the reference point, while IMRT and 3DCRT plans were 45 Gy to 95% of the PTV. Isodose line and dose volume histograms(DVH) were used to evaluate the dose distribution in CTV and OAR. Results: For 10 patients, the average volume of CTV receiving the prescribed dose of CRT was significantly lower than 3DCRT(Q=8.27, P<0.01) and IMRT(Q=8.37, P<0.01), respectively. Comparing with the CRT plan, the 3DCRT and IMRT plans notably reduced the volume of bowel at 30 and 45 Gy levels. The IMRT plan significantly spared rectum and bladder at 30 and 45 Gy levels comparing with the CRT (P<0.01) and 3DCRT(P<0.05) plans, while the 3DCRT plan significantly spared rectum and bladder at 45 Gy level comparing with the CRT(P<0.01) plans. For 4 patients with ovarian transposition, the average doses of ovary over 3 Gy were 2 patients with the 3 DCRT and IMRT plans, and 2 with all three plans. Conclusions: IMRT and 3DCRT are superior to CRT in improving dose coverage of target volume and sparing of OAR, while IMRT being the best. The superiority of IMRT and 3DCRT is obvious in sparing

  20. Sci—Fri PM: Topics — 06: The influence of regional dose sensitivity on salivary loss and recovery in the parotid gland

    Energy Technology Data Exchange (ETDEWEB)

    Clark, H [University of British Columbia, Vancouver, B.C. (Canada); BC Cancer Agency, Surrey, B.C. (Canada); BC Cancer Agency, Vancouver, B.C. (Canada); Thomas, S [BC Cancer Agency, Surrey, B.C. (Canada); Moiseenko, V [University of California San Diego, La Jolla, Ca (United States); Hovan, A; Wu, J [BC Cancer Agency, Vancouver, B.C. (Canada)

    2014-08-15

    Purpose: The Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC 2010) survey of radiation dose-volume effects on salivary gland function has called for improved understanding of intragland dose sensitivity and the effectiveness of partial sparing in salivary glands. Regional dose susceptibility of sagittally- and coronally-sub-segmented parotid gland has been studied. Specifically, we examine whether individual consideration of sub-segments leads to improved prediction of xerostomia compared with whole parotid mean dose. Methods: Data from 102 patients treated for head-and-neck cancers at the BC Cancer Agency were used in this study. Whole mouth stimulated saliva was collected before (baseline), three months, and one year after cessation of radiotherapy. Organ volumes were contoured using treatment planning CT images and sub-segmented into regional portions. Both non-parametric (local regression) and parametric (mean dose exponential fitting) methods were employed. A bootstrap technique was used for reliability estimation and cross-comparison. Results: Salivary loss is described well using non-parametric and mean dose models. Parametric fits suggest a significant distinction in dose response between medial-lateral and anterior-posterior aspects of the parotid (p<0.01). Least-squares and least-median squares estimates differ significantly (p<0.00001), indicating fits may be skewed by noise or outliers. Salivary recovery exhibits a weakly arched dose response: the highest recovery is seen at intermediate doses. Conclusions: Salivary function loss is strongly dose dependent. In contrast no useful dose dependence was observed for function recovery. Regional dose dependence was observed, but may have resulted from a bias in dose distributions.

  1. Radiological study on the change of duct-ligated parotid gland

    International Nuclear Information System (INIS)

    Ohnishi, Takashi

    1994-01-01

    The change of the parotid gland with time following ligation of the main duct was investigated. The duct-ligated parotid gland in rabbit was examined by salivary gland scintigraphy with 99m Tc-pertechnetate ( 99m TcO 4 - ), sialography and microscopic observation. The third day after ligation of the main duct, the outward form of the parotid gland on the static scintigram was not well-defined. On the seventh day, 99m TcO 4 - accumulation was decreased slightly. On the 14th day, atrophy of the parotid gland occurred. The degree of atrophy produced by ligation increases as the duration of the ligation increases. On the 42nd day, the presence of the parotid gland was not recorded practically. The main duct was dilated on the third day. On the seventh day, the intraglandular ducts were bent and strictured. Disappearance of the peripheral duct and atrophy of the parotid gland parenchyma was observed. On microscopic observation, the intraglandular tributaries and the lumen were dilated on the third day. And the reticular fiber was observed that was irregularly formed in parts. The acinar cells were pressed by large and small dilated lumen on the seventh day. On the 14th day, the collagenous fiber around the acini and the duct was increased still more. In addition, fibrosis of the lobule interspace was observed. The degree of atrophy of the acini and lobule was increased maximally on the 42nd day. These results of the salivary gland scintigraphy closely connected with sialograms and microscopic findings. The parotid gland tissue decreases and changings of the duct system were indicated by these imaging methods in detail. (author)

  2. Correlation of osteoradionecrosis and dental events with dosimetric parameters in intensity-modulated radiation therapy for head-and-neck cancer.

    Science.gov (United States)

    Gomez, Daniel R; Estilo, Cherry L; Wolden, Suzanne L; Zelefsky, Michael J; Kraus, Dennis H; Wong, Richard J; Shaha, Ashok R; Shah, Jatin P; Mechalakos, James G; Lee, Nancy Y

    2011-11-15

    Osteoradionecrosis (ORN) is a known complication of radiation therapy to the head and neck. However, the incidence of this complication with intensity-modulated radiation therapy (IMRT) and dental sequelae with this technique have not been fully elucidated. From December 2000 to July 2007, 168 patients from our institution have been previously reported for IMRT of the oral cavity, nasopharynx, larynx/hypopharynx, sinus, and oropharynx. All patients underwent pretreatment dental evaluation, including panoramic radiographs, an aggressive fluoride regimen, and a mouthguard when indicated. The median maximum mandibular dose was 6,798 cGy, and the median mean mandibular dose was 3,845 cGy. Patient visits were retrospectively reviewed for the incidence of ORN, and dental records were reviewed for the development of dental events. Univariate analysis was then used to assess the effect of mandibular and parotid gland dosimetric parameters on dental endpoints. With a median clinic follow-up of 37.4 months (range, 0.8-89.6 months), 2 patients, both with oral cavity primaries, experienced ORN. Neither patient had preradiation dental extractions. The maximum mandibular dose and mean mandibular dose of the 2 patients were 7,183 and 6,828 cGy and 5812 and 5335 cGy, respectively. In all, 17% of the patients (n = 29) experienced a dental event. A mean parotid dose of >26 Gy was predictive of a subsequent dental caries, whereas a maximum mandibular dose >70 Gy and a mean mandibular dose >40 Gy were correlated with dental extractions after IMRT. ORN is rare after head-and-neck IMRT, but is more common with oral cavity primaries. Our results suggest different mechanisms for radiation-induced caries versus extractions. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Correlation of Osteoradionecrosis and Dental Events With Dosimetric Parameters in Intensity-Modulated Radiation Therapy for Head-and-Neck Cancer

    International Nuclear Information System (INIS)

    Gomez, Daniel R.; Estilo, Cherry L.; Wolden, Suzanne L.; Zelefsky, Michael J.; Kraus, Dennis H.; Wong, Richard J.; Shaha, Ashok R.; Shah, Jatin P.; Mechalakos, James G.; Lee, Nancy Y.

    2011-01-01

    Purpose: Osteoradionecrosis (ORN) is a known complication of radiation therapy to the head and neck. However, the incidence of this complication with intensity-modulated radiation therapy (IMRT) and dental sequelae with this technique have not been fully elucidated. Methods and Materials: From December 2000 to July 2007, 168 patients from our institution have been previously reported for IMRT of the oral cavity, nasopharynx, larynx/hypopharynx, sinus, and oropharynx. All patients underwent pretreatment dental evaluation, including panoramic radiographs, an aggressive fluoride regimen, and a mouthguard when indicated. The median maximum mandibular dose was 6,798 cGy, and the median mean mandibular dose was 3,845 cGy. Patient visits were retrospectively reviewed for the incidence of ORN, and dental records were reviewed for the development of dental events. Univariate analysis was then used to assess the effect of mandibular and parotid gland dosimetric parameters on dental endpoints. Results: With a median clinic follow-up of 37.4 months (range, 0.8–89.6 months), 2 patients, both with oral cavity primaries, experienced ORN. Neither patient had preradiation dental extractions. The maximum mandibular dose and mean mandibular dose of the 2 patients were 7,183 and 6,828 cGy and 5812 and 5335 cGy, respectively. In all, 17% of the patients (n = 29) experienced a dental event. A mean parotid dose of >26 Gy was predictive of a subsequent dental caries, whereas a maximum mandibular dose >70 Gy and a mean mandibular dose >40 Gy were correlated with dental extractions after IMRT. Conclusions: ORN is rare after head-and-neck IMRT, but is more common with oral cavity primaries. Our results suggest different mechanisms for radiation-induced caries versus extractions.

  4. Influence of intravenous contrast agent on dose calculations of intensity modulated radiation therapy plans for head and neck cancer

    International Nuclear Information System (INIS)

    Choi, Youngmin; Kim, Jeung-Kee; Lee, Hyung-Sik; Hur, Won-Joo; Hong, Young-Seoub; Park, Sungkwang; Ahn, Kijung; Cho, Heunglae

    2006-01-01

    Background and purpose: To evaluate the effect of an intravenous contrast agent (CA) on dose calculations and its clinical significance in intensity modulated radiation therapy (IMRT) plans for head and neck cancer. Materials and methods: Fifteen patients with head and neck cancer and involved neck nodes were enrolled. Each patient took two sets of computerized tomography (CT) in the same position before and after intravenous CA injections. Target volumes and organs at risk (OAR) were contoured on the enhanced CT, and then an IMRT plan of nine equiangular beams with a 6 MV X-ray was created. After the fusion of non-enhanced and enhanced CTs, the contours and the IMRT plan created from the enhanced CT were copied and placed to the non-enhanced CT. Doses were calculated again from the non-enhanced CT by the same IMRT plan. The radiation doses calculated from the two sets of CTs were compared with regard to planning target volumes (PTV) and the three OARs, both parotid glands and the spinal cord, by Wilcoxon's signed rank test. Results: The doses (maximum, mean, and the dose of 95% of PTV received (D 95% )) of PTV70 and PTV59.4 calculated from the enhanced CTs were lower than those from the non-enhanced CTs (p < 0.05), but the dose differences were less than 1% compared to the doses calculated from the enhanced CTs. The doses of PTV50.4, parotid glands, and spinal cord were not significantly different between the non-enhanced and enhanced CTs. Conclusions: The difference between the doses calculated from the CTs with and without CA enhancement was tolerably small, therefore using intravenous CA could be recommended for the planning CT of head and neck IMRT

  5. Correlation of Osteoradionecrosis and Dental Events With Dosimetric Parameters in Intensity-Modulated Radiation Therapy for Head-and-Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Daniel R., E-mail: dgomez@mdanderson.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Estilo, Cherry L. [Dental Service, Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Wolden, Suzanne L.; Zelefsky, Michael J. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Kraus, Dennis H.; Wong, Richard J.; Shaha, Ashok R.; Shah, Jatin P. [Department of Head and Neck Surgery, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Mechalakos, James G.; Lee, Nancy Y. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2011-11-15

    Purpose: Osteoradionecrosis (ORN) is a known complication of radiation therapy to the head and neck. However, the incidence of this complication with intensity-modulated radiation therapy (IMRT) and dental sequelae with this technique have not been fully elucidated. Methods and Materials: From December 2000 to July 2007, 168 patients from our institution have been previously reported for IMRT of the oral cavity, nasopharynx, larynx/hypopharynx, sinus, and oropharynx. All patients underwent pretreatment dental evaluation, including panoramic radiographs, an aggressive fluoride regimen, and a mouthguard when indicated. The median maximum mandibular dose was 6,798 cGy, and the median mean mandibular dose was 3,845 cGy. Patient visits were retrospectively reviewed for the incidence of ORN, and dental records were reviewed for the development of dental events. Univariate analysis was then used to assess the effect of mandibular and parotid gland dosimetric parameters on dental endpoints. Results: With a median clinic follow-up of 37.4 months (range, 0.8-89.6 months), 2 patients, both with oral cavity primaries, experienced ORN. Neither patient had preradiation dental extractions. The maximum mandibular dose and mean mandibular dose of the 2 patients were 7,183 and 6,828 cGy and 5812 and 5335 cGy, respectively. In all, 17% of the patients (n = 29) experienced a dental event. A mean parotid dose of >26 Gy was predictive of a subsequent dental caries, whereas a maximum mandibular dose >70 Gy and a mean mandibular dose >40 Gy were correlated with dental extractions after IMRT. Conclusions: ORN is rare after head-and-neck IMRT, but is more common with oral cavity primaries. Our results suggest different mechanisms for radiation-induced caries versus extractions.

  6. Benign Fibrous Tumour of the Parotid Gland

    Directory of Open Access Journals (Sweden)

    S.S. Sreetharan

    2005-01-01

    Full Text Available The case of a 44-year-old man with left parotid enlargement that was initially diagnosed as cementifying fibroma is presented. The lesion was found in the deep lobe of the parotid gland and was successfully removed. Postoperatively, the patient recovered well with intact facial nerve function and remained asymptomatic after 1 year. Subsequent histology revealed the mass to be a benign fibrous tumour. The diagnosis and management of this rare entity are discussed.

  7. Morphological pattern of parotid gland tumors

    International Nuclear Information System (INIS)

    Musani, M.A.; Zafar, A.; Malik, S.

    2008-01-01

    To determine the morphological pattern of parotid tumours. During this study, 204 patients with parotid tumours were registered. The patients of all ages and both gender were included in this study. All patients were evaluated by history, clinical examination, F.N.A.C. and ultrasound, C.T/MRI was done in selected cases. All patients were surgically managed and their tumour specimen was sent for histopathology. Classification of individual tumour was based on 1991 World Health Organization Classification. Discrete data was presented in percentage and proportions. Out of 204 cases, 152 (74.5%) were benign and 52 (25.5%) were malignant. Of these, 117 (57.35%) patients were females and 87 (42.65%) males. Benign tumours were more common in females whereas malignant tumours were common in males. The mean age of patients was 34 years and 42 years for benign and malignant tumours respectively. Pleomorphic adenoma was most common benign tumor (83.5%), followed by Warthins tumour. The most common malignant tumour was mucoepidermoid carcinoma (60%), followed by adenoid cystic carcinoma. Superficial lobe of parotid gland was the commonest site, 120 benign and all 52 malignant tumours arising from it while 32 benign tumours originated from deep lobe. Parotid swelling for years was main feature of benign tumours, whereas malignant tumours presented with pain, fixation to skin or underlying structure, cervical lymphadenopathy and facial palsy. Pleomorphic adenoma was the most common benign tumour and mucoepidermoid carcinoma was most common malignant tumour. The morphological patterns and distribution followed the known pattern. (author)

  8. Bladder radiotherapy treatment: A retrospective comparison of 3-dimensional conformal radiotherapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy plans

    Energy Technology Data Exchange (ETDEWEB)

    Pasciuti, Katia, E-mail: k.pasciuti@virgilio.it [Department of Radiotherapy Physics, Royal Free Hospital, London (United Kingdom); Kuthpady, Shrinivas [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom); Anderson, Anne; Best, Bronagh [Department of Radiotherapy Physics, Royal Free Hospital, London (United Kingdom); Waqar, Saleem; Chowdhury, Subhra [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom)

    2017-04-01

    To examine tumor's and organ's response when different radiotherapy plan techniques are used. Ten patients with confirmed bladder tumors were first treated using 3-dimensional conformal radiotherapy (3DCRT) and subsequently the original plans were re-optimized using the intensity-modulated radiation treatment (IMRT) and volumetric-modulated arc therapy (VMAT)-techniques. Targets coverage in terms of conformity and homogeneity index, TCP, and organs' dose limits, including integral dose analysis were evaluated. In addition, MUs and treatment delivery times were compared. Better minimum target coverage (1.3%) was observed in VMAT plans when compared to 3DCRT and IMRT ones confirmed by a statistically significant conformity index (CI) results. Large differences were observed among techniques in integral dose results of the femoral heads. Even if no statistically significant differences were reported in rectum and tissue, a large amount of energy deposition was observed in 3DCRT plans. In any case, VMAT plans provided better organs and tissue sparing confirmed also by the normal tissue complication probability (NTCP) analysis as well as a better tumor control probability (TCP) result. Our analysis showed better overall results in planning using VMAT techniques. Furthermore, a total time reduction in treatment observed among techniques including gantry and collimator rotation could encourage using the more recent one, reducing target movements and patient discomfort.

  9. Necrotizing sialometaplasia of the parotid gland associated with facial nerve paralysis.

    Science.gov (United States)

    Haen, P; Ben Slama, L; Goudot, P; Schouman, T

    2017-02-01

    Necrotizing sialometaplasia is a benign inflammatory lesion involving most frequently the minor salivary gland of the hard palate. Involvement of the parotid gland is rare, involvement of the parotid gland associated with facial palsy is exceptional. A 56-year-old male patient with Marfan syndrome presented with swelling and inflammation of the left parotid gland associated with progressively complete facial nerve paralysis. CT scan and MRI showed a parotid collection with hyper signal of the nearest tissues associated with erosion of the styloid process. A malignant tumor was suspected. The histological examination of a biopsy showed a lobulocentric process with necrosis, squamous metaplasia, and inflammation. The immunohistochemical examination supported a final diagnosis of necrotizing sialometaplasia. Necrotizing sialometaplasia of the parotid gland associated with facial nerve paralysis presents like a malignant neoplasm, both clinically and histologically. Only advanced immunohistochemical examination can really confirm the diagnosis. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  10. Cardiac avoidance in breast radiotherapy: a comparison of simple shielding techniques with intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Landau, David; Adams, Elizabeth J.; Webb, Steve; Ross, Gillian

    2001-01-01

    Background and purpose: Adjuvant breast radiotherapy (RT) is now part of the routine care of patients with early breast cancer. However, analysis of the Early Breast Cancer Trialists' Collaborative suggests that patients with the lowest risk of dying of breast cancer are at significant risk of cardiac mortality due to longer relapse-free survival. Patients with a significant amount of heart in the high-dose volume have been shown to be at risk of fatal cardiac events. This study was designed to assess whether conformal planning or intensity-modulated radiotherapy (IMRT) techniques allow reduced cardiac irradiation whilst maintaining full target coverage. Material and methods: Ten patients with early breast cancer were available for computed tomography (CT) planning. Each had at least 1 cm maximum heart depth within the posterior border of conventional tangents. For each patient, plans were generated and compared using dose volume histograms for planning target volume (PTV) and organs at risk. The plans included conventional tangents with and without shielding. The shielding was designed to either completely spare the heart or to shield as much heart as possible without compromising PTV coverage. IMRT plans were also prepared using two- and four-field tangential and six-field arc-like beam arrangements. Results: PTV homogeneity was better for the tangential IMRT techniques. For all patients, cardiac irradiation was reduced by the addition of partial cardiac shielding to conventional tangents, without compromise of PTV coverage. The two- and four-field IMRT techniques also reduced heart doses. The average percentage volume of heart receiving >60% of the prescription dose was 4.4% (range 1.0-7.1%) for conventional tangents, 1.5% (0.2-3.9%) for partial shielding, 2.3% (0.5-4.6%) for the two-field IMRT technique and 2.2% (0.4-5.6%) for the four-field IMRT technique. For patients with larger maximum heart depths the four-field IMRT plan achieved greater heart sparing

  11. Submandibular gland function and parotid gland function in Bell's palsy, 3

    International Nuclear Information System (INIS)

    Ino, Chiyonori; Yamashita, Toshio; Kato, Mako; Kumazawa, Tadami

    1986-01-01

    With the use of sup(99m)Tc, we attempted to measure simultaneously submandibular gland function and parotid gland function, which is thought not to be controlled by the facial nerve, in patients with unilateral Bell's palsy. For comparison, the lachrymal gland function of some patients was measured by the thread method. We found that facial palsy sometimes affects parotid gland function as well as submandibular gland function. In 60 % of the patients the function of the two glands tended to be affected in the same way. Lachrymal gland function tended to be affected in a similar way to parotid gland function. We conclude that the chorda tympani and the greater petrosal nerve may influence parotid gland function. (author)

  12. Surgical options in benign parotid tumors: a proposal for classification.

    Science.gov (United States)

    Quer, Miquel; Vander Poorten, Vincent; Takes, Robert P; Silver, Carl E; Boedeker, Carsten C; de Bree, Remco; Rinaldo, Alessandra; Sanabria, Alvaro; Shaha, Ashok R; Pujol, Albert; Zbären, Peter; Ferlito, Alfio

    2017-11-01

    Different surgical options are currently available for treating benign tumors of the parotid gland, and the discussion on optimal treatment continues despite several meta-analyses. These options include more limited resections (extracapsular dissection, partial lateral parotidectomy) versus more extensive and traditional options (lateral parotid lobectomy, total parotidectomy). Different schools favor one option or another based on their experience, skills and tradition. This review provides a critical analysis of the literature regarding these options. The main limitation of all the studies is the bias of selection for different surgical approaches. For this reason, we propose a staging system that could facilitate clinical decision making and the comparison of results. We propose four categories based on the size of the tumor and its location within the parotid gland. Category I includes tumors up to 3 cm, which are mobile, close to the outer surface and close to the parotid borders. Category II includes deeper tumors up to 3 cm. Category III comprises tumors greater than 3 cm involving two levels of the parotid gland, and category IV tumors are greater than 3 cm and involve more than 2 levels. For each category and for the various pathologic types, a guideline of surgical extent is proposed. The objective of this classification is to facilitate prospective multicentric studies on surgical techniques in the treatment of benign parotid tumors and to enable the comparison of results of different clinical studies.

  13. MRI features of bilateral parotid haemangiomas of infancy

    International Nuclear Information System (INIS)

    Andronikou, Savvas; Jadwat, Saaleeha; McHugh, Kieran; Linward, Jane

    2003-01-01

    The aim of this article is to report the MRI features of bilateral parotid haemangiomas of infancy and highlight the diagnostic and prognostic value of MRI especially with regard to those lesions that may cause respiratory compromise. Retrospective review of MRI scans in six infants with bilateral parotid haemangiomas. The bilateral haemangiomas were symmetrical in all but one patient. On T1-weighted images the masses were isointense to muscle and on T2 they were hyperintense with numerous small vessels giving a septated appearance. There was vivid enhancement with gadolinium in all cases. In three patients, deep bilateral extensions were demonstrated involving the parapharyngeal spaces resulting in respiratory compromise which required tracheostomy. Bilateral parotid haemangiomas are rare, but when present may have deep extensions, which can result in respiratory compromise requiring tracheostomy. (orig.)

  14. MRI features of bilateral parotid haemangiomas of infancy

    Energy Technology Data Exchange (ETDEWEB)

    Andronikou, Savvas; Jadwat, Saaleeha [Institute of Child Health, University of Cape Town, Klipfontein Road, Rondebosch, 7700, Cape Town (South Africa); McHugh, Kieran; Linward, Jane [Department of Radiology, Great Ormond Street Hospital for Children, London, WC1N 3JH (United Kingdom)

    2003-04-01

    The aim of this article is to report the MRI features of bilateral parotid haemangiomas of infancy and highlight the diagnostic and prognostic value of MRI especially with regard to those lesions that may cause respiratory compromise. Retrospective review of MRI scans in six infants with bilateral parotid haemangiomas. The bilateral haemangiomas were symmetrical in all but one patient. On T1-weighted images the masses were isointense to muscle and on T2 they were hyperintense with numerous small vessels giving a septated appearance. There was vivid enhancement with gadolinium in all cases. In three patients, deep bilateral extensions were demonstrated involving the parapharyngeal spaces resulting in respiratory compromise which required tracheostomy. Bilateral parotid haemangiomas are rare, but when present may have deep extensions, which can result in respiratory compromise requiring tracheostomy. (orig.)

  15. SERUM AND PAROTID FLUIS UREA-LEVELS IN UNREALOADED HEALTHY YOUNG ADULTS

    Science.gov (United States)

    Forty-four healthy young adult male subjects were given oral doses of urea, and parotid fluid and serum urea levels were studied for 1 to 3 hours. A...highly significant correlation between urea in serum and in parotid fluid (r equals 0.982) was found. The indication was that, with flow rate...carefully controlled, parotid fluid could be used interchangeably with serum in urea determination, regardless of the magnitude of the blood concentration. (Author)

  16. Unilateral parotid concentration of radiogallium: Comparison with bilateral uptake and with pertechnetate imaging

    International Nuclear Information System (INIS)

    Levy, H.A.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-01-01

    Unilateral parotid accumulation of radioactivity was noted in 4 elderly (80-95 years) patients after intravenous administration of 67 Ga citrate. In 2 of these individuals, it was possible to carry out pertechnetate salivary gland imaging. The involved glands were functional in terms of pertechnetate accumulation, although no drainage was noted after lemon stimulation. A retrospective analysis of 72 radiogallium studies failed to show unilateral parotid uptake in any of them. However, ten cases (14%) had bilateral parotid accumulation of radiogallium. Probable causes of the bilateral parotid concentration of 67 Ga were discussed. These were compared with poor oral hygiene and dehydration as possible contributing factors to unilateral parotid radiogallium concentration in the elderly. (orig.) [de

  17. Unilateral parotid concentration of radiogallium: Comparison with bilateral uptake and with pertechnetate imaging

    Energy Technology Data Exchange (ETDEWEB)

    Levy, H.A.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-12-01

    Unilateral parotid accumulation of radioactivity was noted in 4 elderly (80-95 years) patients after intravenous administration of /sup 67/Ga citrate. In 2 of these individuals, it was possible to carry out pertechnetate salivary gland imaging. The involved glands were functional in terms of pertechnetate accumulation, although no drainage was noted after lemon stimulation. A retrospective analysis of 72 radiogallium studies failed to show unilateral parotid uptake in any of them. However, ten cases (14%) had bilateral parotid accumulation of radiogallium. Probable causes of the bilateral parotid concentration of /sup 67/Ga were discussed. These were compared with poor oral hygiene and dehydration as possible contributing factors to unilateral parotid radiogallium concentration in the elderly.

  18. Intensity modulated radiotherapy (IMRT) combined with concurrent but not adjuvant chemotherapy in primary nasopharyngeal cancer – a retrospective single center analysis

    International Nuclear Information System (INIS)

    Saleh-Ebrahimi, Ladan; Zwicker, Felix; Muenter, Marc W; Bischof, Marc; Lindel, Katja; Debus, Juergen; Huber, Peter E; Roeder, Falk

    2013-01-01

    We report our experience in 49 consecutive patients with nasopharyngeal carcinoma who were treated by Intensity-modulated radiation therapy (IMRT) combined with simultaneous but not adjuvant chemotherapy (CHT). The medical records of 49 patients with histologically proven primary nasopharygeal carcinoma treated with IMRT and concurrent platin-based CHT (predominantly cisplatin weekly) were retrospectively reviewed. The majority of patients showed advanced clinical stages (stage III/IV:72%) with undifferentiated histology (82%). IMRT was performed in step-and-shoot technique using an integrated boost concept in 84%. In this concept, the boost volume covered the primary tumor and involved nodes with doses of 66–70.4 Gy (single dose 2.2 Gy). Uninvolved regional nodal areas were covered with doses of 54–59.4 Gy (median single dose 1.8 Gy). At least one parotid gland was spared. None of the patients received adjuvant CHT. The median follow-up for the entire cohort was 48 months. Radiation therapy was completed without interruption in all patients and 76% of the patients received at least 80% of the scheduled CHT. Four local recurrences have been observed, transferring into 1-, 3-, and 5-year Local Control (LC) rates of 98%, 90% and 90%. One patient developed an isolated regional nodal recurrence, resulting in 1-, 3-, and 5-year Regional Control (RC) rates of 98%. All locoregional failures were located inside the radiation fields. Distant metastases were found in six patients, transferring into 1-, 3, and 5-year Distant Control (DC) rates of 92%, 86% and 86%. Progression free survival (PFS) rates after 1, 3 and 5 years were 86%, 70% and 69% and 1-, 3- and 5-year Overall Survival (OS) rates were 96%, 82% and 79%. Acute toxicity ≥ grade III mainly consisted of dysphagia (32%), leukopenia (24%), stomatitis (16%), infection (8%) and nausea (8%). Severe late toxicity (grade III) was documented in 18% of the patients, mainly as xerostomia (10%). Concurrent chemoradiation

  19. Age-dependent difference in the computed tomography numbers of the normal parotid gland of Koreans

    International Nuclear Information System (INIS)

    Jeong, Ho Gul; Lee, Eun Sook; Kim, Kee Deog; Park, Chang Seo

    1999-01-01

    To determine normal CT number range of parotid gland by analyzing the change by age increase and the difference among individuals and between both sexes in CT number of normal parotid gland. 134 subjects who took the CT scan between the period of Jan. 1996 and Dec. 1997 at Yonsei University, Dental Hospital were selected. Criteria for selection were that the patients must be within the normal range clinically and radiologically, and the entire parotid gland on the axial view must be shown. Among the axial views, the one showing the greatest parotid gland size was selected and its CT number was recorded. Also, CT numbers from both masseter muscle were recorded as its control. There was statistically significant correlation between CT number of right and left of parotid glands and masseter muscles. With the increase of age, there is a significant decrease in the CT number of parotid gland (p 0.05). As age increases, CT number of parotid gland has a tendency to decrease, and there is no significant difference in the CT numbers between left and right parotid gland. Therefore in the CT scan of patients suspected of having an salivary gland disease of the parotid gland, to consider normal range of the age-dependent CT numbers of parotid gland and compare the CT numbers of the right and left parotid gland might be useful in diagnosing the disease.

  20. An intraoperative diagnosis of parotid gland tumors using Raman spectroscopy and support vector machine

    International Nuclear Information System (INIS)

    Yan, Bing; Wen, Zhining; Li, Yi; Li, Longjiang; Xue, Lili

    2014-01-01

    The preoperative and intraoperative diagnosis of parotid gland tumors is difficult, but is important for their surgical management. In order to explore an intraoperative diagnostic method, Raman spectroscopy is applied to detect the normal parotid gland and tumors, including pleomorphic adenoma, Warthin’s tumor and mucoepidermoid carcinoma. In the 600–1800 cm −1 region of the Raman shift, there are numerous spectral differences between the parotid gland and tumors. Compared with Raman spectra of the normal parotid gland, the Raman spectra of parotid tumors show an increase of the peaks assigned to nucleic acids and proteins, but a decrease of the peaks related to lipids. Spectral differences also exist between the spectra of parotid tumors. Based on these differences, a remarkable classification and diagnosis of the parotid gland and tumors are carried out by support vector machine (SVM), with high accuracy (96.7∼100%), sensitivity (93.3∼100%) and specificity (96.7∼100%). Raman spectroscopy combined with SVM has a great potential to aid the intraoperative diagnosis of parotid tumors and could provide an accurate and rapid diagnostic approach. (paper)

  1. Evaluation of a leaf position optimization tool for intensity modulated radiation therapy of head and neck cancer

    International Nuclear Information System (INIS)

    Claus, Filip; Gersem, Werner de; Vanhoutte, Ilse; Duthoy, Wim; Remouchamps, Vincent; Wagter, Carlos de; Neve, Wilfried de

    2001-01-01

    Background and purpose: Since 1996, patients are treated at Ghent University Hospital with a multi-segment technique using MultiLeaf Collimators. The segments were obtained by using the Beam's eye view projections of the planning target volume (PTV) and the organs at risk (OARs), after which the segments weights were optimized. To investigate if optimization of the leaf positions would further improve the intensity modulated radiation therapy (IMRT) plans, a tool optimizing leaf positions and segment weights simultaneously, was developed. This tool is called SOWAT, which is the acronym for segment outline and weight adapting tool. Material and methods: The tool evaluates the effects of changing the position of each collimating leaf of all segments on the value of the objective function. Only changes that improve the value of the objective function are retained. Between December 1999 and January 2001, 30 head and neck patients were treated with IMRT. Two patient groups were distinguished: pharyngeal and laryngeal tumors (n=17) and sinonasal tumors (n=13). A specific set of physical endpoints was evaluated for each group. Dose statistics of the treatment plans without and with SOWAT were analyzed. Results: When using SOWAT for the pharyngeal and laryngeal cases, the PTV dose homogeneity increased with a median of 11% (range 2-27%), while the maximum dose to the spinal cord was decreased for 14 of the 17 patients. In four plans where parotid function preservation was a goal, the parotid mean dose was lower than 26 Gy in one plan without SOWAT, and in four plans with SOWAT. For the sinonasal tumors, the PTV dose homogeneity increased with a median of 7% (range 1-14%). SOWAT lowered the mean dose to 53 of the 63 optic pathway structures (retina, optic nerve and optic chiasm). SOWAT leaves the number of segments unchanged and has little or no effect on the delivery time. Conclusions: SOWAT is a powerful tool to perform the final optimization of IMRT plans, without

  2. The use of biologically related model (Eclipse for the intensity-modulated radiation therapy planning of nasopharyngeal carcinomas.

    Directory of Open Access Journals (Sweden)

    Monica W K Kan

    Full Text Available Intensity-modulated radiation therapy (IMRT is the most common treatment technique for nasopharyngeal carcinoma (NPC. Physical quantities such as dose/dose-volume parameters are used conventionally for IMRT optimization. The use of biological related models has been proposed and can be a new trend. This work was to assess the performance of the biologically based IMRT optimization model installed in a popular commercial treatment planning system (Eclipse as compared to its dose/dose volume optimization model when employed in the clinical environment for NPC cases.Ten patients of early stage NPC and ten of advanced stage NPC were selected for this study. IMRT plans optimized using biological related approach (BBTP were compared to their corresponding plans optimized using the dose/dose volume based approach (DVTP. Plan evaluation was performed using both biological indices and physical dose indices such as tumor control probability (TCP, normal tissue complication probability (NTCP, target coverage, conformity, dose homogeneity and doses to organs at risk. The comparison results of the more complex advanced stage cases were reported separately from those of the simpler early stage cases.The target coverage and conformity were comparable between the two approaches, with BBTP plans producing more hot spots. For the primary targets, BBTP plans produced comparable TCP for the early stage cases and higher TCP for the advanced stage cases. BBTP plans reduced the volume of parotid glands receiving doses of above 40 Gy compared to DVTP plans. The NTCP of parotid glands produced by BBTP were 8.0 ± 5.8 and 7.9 ± 8.7 for early and advanced stage cases, respectively, while those of DVTP were 21.3 ± 8.3 and 24.4 ± 12.8, respectively. There were no significant differences in the NTCP values between the two approaches for the serial organs.Our results showed that the BBTP approach could be a potential alternative approach to the DVTP approach for NPC.

  3. SU-F-T-187: Quantifying Normal Tissue Sparing with 4D Robust Optimization of Intensity Modulated Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Newpower, M; Ge, S; Mohan, R [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To report an approach to quantify the normal tissue sparing for 4D robustly-optimized versus PTV-optimized IMPT plans. Methods: We generated two sets of 90 DVHs from a patient’s 10-phase 4D CT set; one by conventional PTV-based optimization done in the Eclipse treatment planning system, and the other by an in-house robust optimization algorithm. The 90 DVHs were created for the following scenarios in each of the ten phases of the 4DCT: ± 5mm shift along x, y, z; ± 3.5% range uncertainty and a nominal scenario. A Matlab function written by Gay and Niemierko was modified to calculate EUD for each DVH for the following structures: esophagus, heart, ipsilateral lung and spinal cord. An F-test determined whether or not the variances of each structure’s DVHs were statistically different. Then a t-test determined if the average EUDs for each optimization algorithm were statistically significantly different. Results: T-test results showed each structure had a statistically significant difference in average EUD when comparing robust optimization versus PTV-based optimization. Under robust optimization all structures except the spinal cord received lower EUDs than PTV-based optimization. Using robust optimization the average EUDs decreased 1.45% for the esophagus, 1.54% for the heart and 5.45% for the ipsilateral lung. The average EUD to the spinal cord increased 24.86% but was still well below tolerance. Conclusion: This work has helped quantify a qualitative relationship noted earlier in our work: that robust optimization leads to plans with greater normal tissue sparing compared to PTV-based optimization. Except in the case of the spinal cord all structures received a lower EUD under robust optimization and these results are statistically significant. While the average EUD to the spinal cord increased to 25.06 Gy under robust optimization it is still well under the TD50 value of 66.5 Gy from Emami et al. Supported in part by the NCI U19 CA021239.

  4. CT-diagnosis for mass lesions in the parotid gland and cervical region

    International Nuclear Information System (INIS)

    Matsuyama, Fumihiko; Taniguchi, Satomi; Horii, Masaru; Suzuki, Shigemi; Shiba, Yuko

    1982-01-01

    Thirty patients suffering from mass lesion in the parotid gland or cervical region were examined by computed tomography (CT). The photographed images were compared with the findings and pathological diagnoses obtained by surgical procedures. The conclusions were as follows: 1) Plain CT demonstrated the location of the parotid tumor. Contrast enhancement seemed to delineate the margin of the tumor more clearly. 2) By contrast enhancement, the branchiogenic cyst was differentiated from the parotid tumor, as a low density mass with an enhanced cyst wall. 3) Parotid tumors enhanced by contrast material did not always appear as solid tumors. 4) In some cases, CT numbers indicated the contents of the tumor. 5) The extension of the tumor to the parapharyngeal space was clearly depicted on CT. 6) It seemed to be difficult to evaluate the relationship of the parotid tumor to the facial nerve on plain CT. (author)

  5. CT-diagnosis for mass lesions in the parotid gland and cervical region

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, F.; Taniguchi, S.; Horii, M.; Suzuki, S.; Shiba, Y. (Kobe Central Municipal Hospital (Japan))

    1982-02-01

    Thirty patients suffering from mass lesion in the parotid gland or cervical region were examined by computed tomography (CT). The photographed images were compared with the findings and pathological diagnoses obtained by surgical procedures. The conclusions were as follows: 1) Plain CT demonstrated the location of the parotid tumor. Contrast enhancement seemed to delineate the margin of the tumor more clearly. 2) By contrast enhancement, the branchiogenic cyst was differentiated from the parotid tumor, as a low density mass with an enhanced cyst wall. 3) Parotid tumors enhanced by contrast material did not always appear as solid tumors. 4) In some cases, CT numbers indicated the contents of the tumor. 5) The extension of the tumor to the parapharyngeal space was clearly depicted on CT. 6) It seemed to be difficult to evaluate the relationship of the parotid tumor to the facial nerve on plain CT.

  6. Parasympathetic denervation increases responses to VIP in isolated rat parotid acini

    International Nuclear Information System (INIS)

    McMillian, M.K.; Talamo, B.R.

    1989-01-01

    Vasoactive intestinal peptide (VIP) is a putative neurotransmitter found in the salivary glands of many species, including the rat parotid gland. Parasympathetic denervation has been reported to deplete VIP in the rat parotid gland and to lead to supersensitivity to this peptide in vivo. We have compared the effects of VIP on acini isolated from parasympathetically denervated and unoperated parotid glands to examine possible supersensitivity to the peptide in vitro. VIP normally produced responses similar to those obtained with a low concentration of the beta adrenergic agonist isoproterenol (ISO), but strikingly different from the effects obtained with the muscarinic agonist carbachol (CARB). In parotid membrane preparations, VIP stimulated adenylate cyclase activity. Dissociated acini treated with VIP showed increases in cAMP accumulation and amylase release which were potentiated by forskolin and also by inhibition of phosphodiesterase. After parasympathetic denervation, maximal effects of VIP on adenylate cyclase, cAMP accumulation and amylase release in intact cells were increased two- to five-fold over contralateral control (or unoperated) parotid responses. The increase in adenylate cyclase-mediated responses after denervation was specific to VIP; there was no increased response nor increased sensitivity of any of these responses to ISO. Specific [125I]VIP binding to parotid acini increased two-fold per gland and three-fold per mg of protein after denervation; this probably explains the observed increases in the response to VIP

  7. Preauricular infratemporal fossa approach for advanced malignant parotid tumors.

    Science.gov (United States)

    Leonetti, John P; Benscoter, Brent J; Marzo, Sam J; Borrowdale, Richard W; Pontikis, George C

    2012-09-01

    The aims of this study were to demonstrate the surgical technique involved in the preauricular infratemporal fossa (ITF) approach, outline the clinical indications for use of this technique, and present the results in using this approach in 159 patients with malignant parotid tumors. At the conclusion of this article, the reader should be able to understand the utility of the preauricular infratemporal fossa approach in the management of patients with advanced malignant parotid tumors. This was a retrospective chart review of 159 patients treated at a tertiary care academic medical center following institutional review board approval. A comprehensive medical records review was performed for all patients with malignant parotid tumors who underwent a preauricular ITF approach between July 1988 and July 2010. The most common presenting symptoms were pain and trismus, whereas the presence of a parotid mass and facial paralysis were the most common clinical signs. Mucoepidermoid and adenoid cystic carcinoma accounted for 63% of the tumors, and perineural invasion was found in nearly 71% of the patients. Despite negative surgical margins in 92% of the patients, local or regional tumor recurrence was found in 17% of the cases. The mean follow-up time was 12.8 years. The preauricular ITF approach should be used in the surgical extirpation of advanced malignant parotid neoplasms. This technique provides proximal facial nerve identification, internal carotid artery protection, and negative tumor margins at the skull base. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  8. Parotid gland shrinkage during IMRT predicts the time to Xerostomia resolution.

    Science.gov (United States)

    Sanguineti, Giuseppe; Ricchetti, Francesco; Wu, Binbin; McNutt, Todd; Fiorino, Claudio

    2015-01-17

    To assess the impact of mid-treatment parotid gland shrinkage on long term xerostomia during IMRT for oropharyngeal SCC. All patients treated with IMRT at a single Institution from November 2007 to June 2010 and undergoing weekly CT scans were selected. Parotid glands were contoured retrospectively on the mid treatment CT scan. For each parotid gland, the percent change relative to the planning volume was calculated and combined as weighted average. Patients were considered to be xerostomic if developed GR2+ dry mouth according to CTCAE v3.0. Predictors of the time to xerostomia resolution or downgrade to 1 were investigated at both uni- and multivariate analysis. 85 patients were selected. With a median follow up of 35.8 months (range: 2.4-62.6 months), the actuarial rate of xerostomia is 26.2% (SD: 5.3%) and 15.9% (SD: 5.3%) at 2 and 3 yrs, respectively. At multivariate analysis, mid-treatment shrink along with weighted average mean parotid dose at planning and body mass index are independent predictors of the time to xerostomia resolution. Patients were pooled in 4 groups based on median values of both mid-treatment shrink (cut-off: 19.6%) and mean WA parotid pl-D (cut-off: 35.7 Gy). Patients with a higher than median parotid dose at planning and who showed poor shrinkage at mid treatment are the ones with the outcome significantly worse (3-yr rate of xerostomia ≈ 50%) than the other three subgroups (3-yr rate of xerostomia ≈ 10%). For a given planned dose, patients whose parotids significantly shrink during IMRT are less likely to be long-term supplemental fluids dependent.

  9. Giant Parotid Pleomorphic Adenoma Involving Parapharyngeal Space

    Directory of Open Access Journals (Sweden)

    Sukri Rahman

    2013-09-01

    Full Text Available AbstrakLatar belakang: Pleomorfik adenoma parotis merupakan tumor jinak kelenjar liur yang paling sering ditemukan, namun pleomorfik adenoma parotis yang sangat besar sehingga melibatkan ruang parafaring (RPF sangat jarang. Diagnosis ini sulit ditegakkan karena gejala klinisnya tidak khas. Penatalaksanaanya harus hati-hati mengingat banyak struktur vital yang beresiko mengalami trauma. Tujuan: Bagaimana menegakkan diagnosis dan penatalaksanaan pleomorfik adenoma parotis yang melibatkan RPF. Kasus: Seorang pasien perempuan 27 tahun ditegakkan diagnosis pleomorfik adenoma parotis kanan dengan melibatkan RPF. Terdapat pembengkakan pada leher yang bersifat asimtomatis dan gejala pendorongan faring dan laring yang menyebabkan disfonia, disfagia, dan defisit saraf kranial IX,X,XII. Penatalaksanaan: Pasien telah dilakukan operasi parotidektomi pendekatan transervikal–transparotid dengan preservasi arteri karotis eksterna dan saraf fasialis. Kesimpulan: Biopsi Aspirasi Jarum Halus (BAJAH dan radiologi merupakan pemeriksaan yang penting untuk menegakkan diagnosis. Penatalaksanaan pleomorfik adenoma parotis yang melibatkan RPF adalah bedah ekstirpasi komplit dengan beberapa pendekatan. .Kata kunci: tumor jinak kelenjar liur, pleomorfik adenoma, ruang parafaringAbstractBackground: Parotid pleomorphic adenoma is the most common benign salivary gland tumor, while giant parotid pleomorphic adenoma involving the parapharyngeal space (PPS is rare. It was difficult to diagnose because the clinical presentation of this tumor can be subtle. The management must be performed carefully due to anatomy relation to complex vital structure lead to traumatic injury highrisk. Purposes: How to make diagnosis and management parotid pleomorphic adenoma involving PPS. Case: A female 27 years old with diagnosis was giant parotid pleomorphic adenoma involving PPS. There was asymptomatic swelling of the neck and presence of pushing the pharynx and larynx medially causes

  10. Intensity-modulated stereotactic radiosurgery using dynamic micro-multileaf collimation

    International Nuclear Information System (INIS)

    Benedict, Stanley H.; Cardinale, Robert M.; Wu Qiuwen; Zwicker, Robert D.; Broaddus, William C.; Mohan, Radhe

    2001-01-01

    Purpose: The implementation of dynamic leaf motion on a micro-multileaf collimator system provides the capability for intensity-modulated stereotactic radiosurgery (IMSRS), and the consequent potential for improved dose distributions for irregularly shaped tumor volumes adjacent to critical organs. This study explores the use of IMSRS to provide improved tumor coverage and normal tissue sparing for small cranial tumors relative to plans based on multiple fixed uniform-intensity beams or traditional circular collimator arc-based stereotactic techniques. Methods and Materials: Four patient cases involving small brain lesions are presented and analyzed. The cases were chosen to include a representative selection of target shapes, number of targets, and adjacent critical areas. Patient plans generated for these comparisons include standard arcs with multiple circular collimators, and fixed noncoplanar static fields with uniform-intensity beams and IMSRS. Parameters used for evaluation of the plans include the percentage of irradiated volume to tumor volume (PITV), normal tissue dose-volume histograms, and dose-homogeneity ratios. All IMSRS plans were computed using previously established IMRT techniques adapted for use with the BrainLAB M3 micro-multileaf collimator. The algorithms comprising the IMRT system for optimization of intensity distributions and conversion into leaf trajectories of the BrainLab M3 were developed at our institution. The ADAC Pinnacle 3 radiation treatment-planning system was used for dose calculations and for input of contours for target volumes and normal critical structures. Results: For all cases, the IMSRS plans showed a high degree of conformity of the dose distribution with the target shape. The IMSRS plans provided either (1) a smaller volume of normal tissue irradiated to significant dose levels, generally taken as doses greater than 50% of the prescription, or (2) a lower dose to an important adjacent critical organ. The reduction in

  11. Malignant fibrous histiocytoma of the parotid gland associated with polycythemia

    NARCIS (Netherlands)

    van Wingerden, J. J.; van Rensburg, P. G.; Coetzee, B. P.

    1986-01-01

    Although malignant fibrous histiocytoma (MFH) is thought to be the most common soft tissue tumor of late adult life, it is extremely uncommon in the parotid gland. A case of MFH in the parotid is reported, associated with polycythemia, which remitted following surgical extirpation of the tumor

  12. Parotid-Absorbed Doses: A Comparison Between Spiral Tomography and Panoramic

    Directory of Open Access Journals (Sweden)

    Ehsan Hekmatian

    2016-07-01

    Full Text Available Background Jaws spiral tomography and panoramic radiography have wide applications in dentistry, and the parotid gland is one of the most sensitive organs of the head and neck. Objectives The aim of this study was to evaluate and compare the parotid-absorbed dose in spiral tomography and panoramic radiographs using a thermoluminescent dosimeter. Materials and Methods A radiation analog dosimetry phantom was placed in a Cranex Tome radiograph device, and a parotid absorbed dose was measured in both techniques. Thermoluminescent dosimeters were placed bilaterally in the parotid region (on the tube side and the opposite side. Spiral tomography dosimetry was done for the upper and lower jaws in the anterior and posterior regions. Each region contained four slices of 2 mm and four slices of 4 mm in thickness. The results were analyzed by a Wilcoxon test. Results For the tube side parotid, the average absorbed doses in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice thickness, were 1.70/1.40 and 1.65/1.60 mGy, respectively. The average absorbed doses with the 4mm slices were 1.65/1.70 and 1.75/1.57 mGy, respectively. For the opposite parotid, the average absorbed dose in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice thickness, were 1.40/1.30 and 1.40/1.67 mGy, respectively. The average absorbed doses with the 4mm slices were 1.50/1.66 and 1.40/1.50 mGy, respectively. The average absorbed dose of the panoramic radiograph was 1.40 mGy. Conclusions There was no statistically significant difference in the parotid absorbed dose between spiral tomography and a panoramic radiograph (P value = 0.18. The overall results of this study were similar to other studies.

  13. Two cases of cystic lesions in the parotid region diagnosed by CT sialogram

    International Nuclear Information System (INIS)

    Kubo, Masahiko; Ukai, Kotaro; Itoh, Hiroshi; Miyoshi, Yasuro; Itoh, Yukiko; Kohdera, Urara; Taki, Norio; Furukawa, Yuichi.

    1985-01-01

    This is a case report of two patients with cystic lesions in the parotid region. The diagnostic value of CT sialogram is discussed. A 62-year-old male had a swelling in the left parotid region which felt cystic on manual palpation. A CT sialogram clearly demonstrated a cystic mass superficial to the parotid gland. Histologically, the mass was an epidermoid cyst. A 9-year-old male had pain and swelling in the right parotid region which was not reduced by antibiotic therapy. An extraparotid abscess was diagnosed by CT sialogram 14 days after the onset. CT sialogram is effective in differentiating intrinsic from extrinsic parotid lesions and also shows the relationship of the tumor mass to the facial nerve and helps to differentiate between benign and malignant neoplasms. (author)

  14. Intensity modulated radiotherapy (IMRT) with compensators

    International Nuclear Information System (INIS)

    Salz, H.; Wiezorek, T.; Scheithauer, M.; Kleen, W.; Schwedas, M.; Wendt, T.G.

    2002-01-01

    The irradiation with intensity-modulated fields is possible with static as well as dynamic methods. In our university hospital, the intensity-modulated radiotherapy (IMRT) with compensators was prepared and used for the first time for patient irradiation in July 2001. The compensators consist of a mixture of tin granulate and wax, which is filled in a milled negative mould. The treatment planning is performed with Helax-TMS (MDS Nordion). An additional software is used for editing the modulation matrix ('Modifix'). Before irradiation of the first patient, extensive measurements have been carried out in terms of quality assurance of treatment planning and production of compensators. The results of the verification measurements have shown that IMRT with compensators possesses high spatial and dosimetric exactness. The calculated dose distributions are applied correctly. The accuracy of the calculated monitor units is normally better than 3%; in small volumes, further dosimetric inaccuracies between calculated and measured dose distributions are mostly less than 3%. Therefore, the compensators contribute to the achievement of high-level IMRT even when apparatuses without MLC are used. This paper describes the use of the IMRT with compensators, presents the limits of this technology, and discusses the first practical experiences. (orig.) [de

  15. Intensity-modulated whole pelvic radiotherapy in women with gynecologic malignancies

    International Nuclear Information System (INIS)

    Mundt, Arno J.; Lujan, Anthony E.; Rotmensch, Jacob; Waggoner, Steven E.; Yamada, S. Diane; Fleming, Gini; Roeske, John C.

    2002-01-01

    Purpose: To describe our initial clinical experience with intensity-modulated whole pelvic radiotherapy (IM-WPRT) in women with gynecologic malignancies. Methods and Materials: Between February 2000 and August 2001, 40 gynecology patients underwent IM-WPRT. After fabrication of customized immobilization, all patients underwent contrast-enhanced CT, and a clinical target volume was contoured consisting of the upper vagina, parametria, uterus (if present), and presacral and pelvic lymph node regions. The clinical target volume was expanded by 1 cm to create a planning target volume (PTV). Using commercially available software, 7- or 9-field, 6-MV, coplanar IM-WPRT plans were generated for all patients. The worst acute gastrointestinal and genitourinary toxicity during treatment was scored on a 4-point scale: 0, none; 1, mild, no medications required; 2, moderate, medications required; and 3, severe, treatment breaks or cessation, hospitalization. As a comparison, acute toxicities in 35 previously treated conventional WPRT patients were analyzed. No significant differences were noted in the clinicopathologic and treatment factors between the two groups. Results: IM-WPRT plans provided excellent PTV coverage, with considerable sparing of the surrounding normal tissues. On average, 98.1% of the PTV received the prescription dose. The average percentage of the PTV receiving 110% and 115% of the prescription dose was 9.8% and 0.2%, respectively. IM-WPRT was well tolerated, with no patient developing Grade 3 toxicity. Grade 2 acute gastrointestinal toxicity was less common in the IM-WPRT group (60 vs. 91%, p=0.002) than in the conventional WPRT group. Moreover, the percentage of IM-WPRT and WPRT patients requiring no or only infrequent antidiarrheal medications was 75% and 34%, respectively (p=0.001). Although less Grade 2 genitourinary toxicity was seen in the IM-WPRT group (10% vs. 20%), this difference was not statistically significant (p=0.22). Conclusion: IM-WPRT is a

  16. Impact of gantry rotation time on plan quality and dosimetric verification. Volumetric modulated arc therapy (VMAT) vs. intensity modulated radiotherapy (IMRT)

    Energy Technology Data Exchange (ETDEWEB)

    Pasler, Marlies; Wirtz, Holger; Lutterbach, Johannes [Gemeinschaftspraxis fuer Strahlentherapie Singen-Friedrichshafen, Singen (Germany)

    2011-12-15

    To compare plan quality criteria and dosimetric accuracy of step-and-shoot intensity-modulated radiotherapy (ss-IMRT) and volumetric modulated arc radiotherapy (VMAT) using two different gantry rotation times. This retrospective planning study based on 20 patients was comprised of 10 prostate cancer (PC) and 10 head and neck (HN) cancer cases. Each plan contained two target volumes: a primary planning target volume (PTV) and a boost volume. For each patient, one ss-IMRT plan and two VMAT plans at 90 s (VMAT90) and 120 s (VMAT120) per arc were generated with the Pinnacle {sup copyright} planning system. Two arcs were provided for the PTV plans and a single arc for boost volumes. Dosimetric verification of the plans was performed using a 2D ionization chamber array placed in a full scatter phantom. VMAT reduced delivery time and monitor units for both treatment sites compared to IMRT. VMAT120 vs. VMAT90 increased delivery time and monitor units in PC plans without improving plan quality. For HN cases, VMAT120 provided comparable organs at risk sparing and better target coverage and conformity than VMAT90. In the VMAT plan verification, an average of 97.1% of the detector points passed the 3 mm, 3% {gamma} criterion, while in IMRT verification it was 98.8%. VMAT90, VMAT120, and IMRT achieved comparable treatment plans. Slower gantry movement in VMAT120 plans only improves dosimetric quality for highly complex targets.

  17. Impact of gantry rotation time on plan quality and dosimetric verification. Volumetric modulated arc therapy (VMAT) vs. intensity modulated radiotherapy (IMRT)

    International Nuclear Information System (INIS)

    Pasler, Marlies; Wirtz, Holger; Lutterbach, Johannes

    2011-01-01

    To compare plan quality criteria and dosimetric accuracy of step-and-shoot intensity-modulated radiotherapy (ss-IMRT) and volumetric modulated arc radiotherapy (VMAT) using two different gantry rotation times. This retrospective planning study based on 20 patients was comprised of 10 prostate cancer (PC) and 10 head and neck (HN) cancer cases. Each plan contained two target volumes: a primary planning target volume (PTV) and a boost volume. For each patient, one ss-IMRT plan and two VMAT plans at 90 s (VMAT90) and 120 s (VMAT120) per arc were generated with the Pinnacle copyright planning system. Two arcs were provided for the PTV plans and a single arc for boost volumes. Dosimetric verification of the plans was performed using a 2D ionization chamber array placed in a full scatter phantom. VMAT reduced delivery time and monitor units for both treatment sites compared to IMRT. VMAT120 vs. VMAT90 increased delivery time and monitor units in PC plans without improving plan quality. For HN cases, VMAT120 provided comparable organs at risk sparing and better target coverage and conformity than VMAT90. In the VMAT plan verification, an average of 97.1% of the detector points passed the 3 mm, 3% γ criterion, while in IMRT verification it was 98.8%. VMAT90, VMAT120, and IMRT achieved comparable treatment plans. Slower gantry movement in VMAT120 plans only improves dosimetric quality for highly complex targets.

  18. Serie de 8 casos de parotiditis supurada aguda neonatal

    Directory of Open Access Journals (Sweden)

    Manuel Díaz Álvarez

    Full Text Available La parotiditis supurada aguda es una infección poco frecuente en la práctica del pediatra y neonatólogo. El objetivo es mostrar nuestra experiencia en la atención de serie de casos con parotiditis supurada aguda en el período neonatal, y describir sus características de presentación. Se presentan los hallazgos clínicos en 8 pacientes con parotiditis supurativa neonatal, quienes estuvieron ingresados en el Servicio de Neonatología del Hospital Pediátrico Universitario "Juan Manuel Márquez", durante el período de 22 años (desde el año 1992 hasta el año 2013, y se contrasta con los reportes publicados en la literatura internacional. Las características de presentación de la parotiditis aguda supurada de nuestros casos concuerdan con la literatura revisada en muchos aspectos, y se demuestra que es, además, una infección poco frecuente en el período neonatal. Es la primera publicación sobre esta entidad en neonatos en Cuba, y la mayor serie de casos en el ámbito latinoamericano.

  19. Fractal Dimension Of CT Images Of Normal Parotid Glands

    International Nuclear Information System (INIS)

    Lee, Sang Jin; Heo, Min Suk; You, Dong Soo

    1999-01-01

    This study was to investigate the age and sex differences of the fractal dimension of the normal parotid glands in the digitized CT images. The six groups, which were composed of 42 men and women from 20's, 40's and 60's and over were picked. Each group contained seven people of the same sex. The normal parotid CT images were digitized, and their fractal dimensions were calculated using Scion Image PC program. The mean of fractal dimensions in males was 1.7292 (+/-0.0588) and 1.6329 (+/-0.0425) in females. The mean of fractal dimensions in young males was 1.7617, 1.7328 in middle males, and 1.6933 in old males. The mean of fractal dimensions in young females was 1.6318, 1.6365 in middle females, and 1.6303 in old females. There was no statistical difference in fractal dimension between left and right parotid gland of the same subject (p>0.05). Fractal dimensions in male were decreased in older group (p 0.05). The fractal dimension of parotid glands in the digitized CT images will be useful to evaluate the age and sex differences.

  20. Comparison of Planning Quality and Efficiency Between Conventional and Knowledge-based Algorithms in Nasopharyngeal Cancer Patients Using Intensity Modulated Radiation Therapy.

    Science.gov (United States)

    Chang, Amy T Y; Hung, Albert W M; Cheung, Fion W K; Lee, Michael C H; Chan, Oscar S H; Philips, Helen; Cheng, Yung-Tang; Ng, Wai-Tong

    2016-07-01

    Intensity modulated radiation therapy (IMRT) is widely used to achieve a highly conformal dose and improve treatment outcome. However, plan quality and planning time are institute and planner dependent, and no standardized tool exists to recognize an optimal plan. RapidPlan, a knowledge-based algorithm, can generate constraints to assist optimization and produce high-quality IMRT plans. This report evaluated the quality and efficiency of using RapidPlan in nasopharyngeal carcinoma (NPC) IMRT planning. RapidPlan was configured using 79 radical IMRT plans for NPC; 20 consecutive NPC patients indicated for radical radiation therapy between October 2014 and May 2015 were then recruited to assess its performance. The ability of RapidPlan to produce acceptable plans was evaluated. For plans that could not achieve clinical acceptance, manual touch-up was performed. The IMRT plans produced without RapidPlan (manual plans) and with RapidPlan (RP-2 plans, including those with manual touch-up) were compared in terms of dosimetric quality and planning efficiency. RapidPlan by itself could produce clinically acceptable plans for 9 of the 20 patients; manual touch-up increased the number of acceptable plans (RP-2 plans) to 19. The target dose coverage and conformity were very similar. No difference was found in the maximum dose to the brainstem and optic chiasm. RP-2 plans delivered a higher maximum dose to the spinal cord (46.4 Gy vs 43.9 Gy, P=.002) but a lower dose to the parotid (mean dose to right parotid, 37.3 Gy vs 45.4 Gy; left, 34.4 Gy vs 43.1 Gy; Pquality IMRT plans for NPC patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. A method of simulating intensity modulation-direct detection WDM systems

    Institute of Scientific and Technical Information of China (English)

    HUANG Jing; YAO Jian-quan; LI En-bang

    2005-01-01

    In the simulation of Intensity Modulation-Direct Detection WDM Systems,when the dispersion and nonlinear effects play equally important roles,the intensity fluctuation caused by cross-phase modulation may be overestimated as a result of the improper step size.Therefore,the step size in numerical simulation should be selected to suppress false XPM intensity modulation (keep it much less than signal power).According to this criterion,the step size is variable along the fiber.For a WDM system,the step size depends on the channel separation.Different type of transmission fiber has different step size.In the split-step Fourier method,this criterion can reduce simulation time,and when the step size is bigger than 100 meters,the simulation accuracy can also be improved.

  2. Rapid Arc, helical tomotherapy, sliding window intensity modulated radiotherapy and three dimensional conformal radiation for localized prostate cancer: A dosimetric comparison

    Directory of Open Access Journals (Sweden)

    Rajesh A Kinhikar

    2014-01-01

    Full Text Available Objective: The objective of this study was to investigate the potential role of RapidArc (RA compared with helical tomotherapy (HT, sliding window intensity modulated radiotherapy (SW IMRT and three-dimensional conformal radiation therapy (3D CRT for localized prostate cancer. Materials and Methods: Prescription doses ranged from 60 Gy to planning target volume (PTV and 66.25 Gy for clinical target volume prostate (CTV-P over 25-30 fractions. PTV and CTV-P coverage were evaluated by conformity index (CI and homogeneity index (HI. Organ sparing comparison was done with mean doses to rectum and bladder. Results: CI 95 were 1.0 ± 0.01 (RA, 0.99 ± 0.01 (HT, 0.97 ± 0.02 (IMRT, 0.98 ± 0.02 (3D CRT for PTV and 1.0 ± 0.00 (RA, HT, SW IMRT and 3D CRT for CTV-P. HI was 0.11 ± 0.03 (RA, 0.16 ± 0.08 (HT, 0.12 ± 0.03 (IMRT, 0.06 ± 0.01 (3D CRT for PTV and 0.03 ± 0.00 (RA, 0.05 ± 0.01 (HT, 0.03 ± 0.01 (SW IMRT and 3D CRT for CTV-P. Mean dose to bladder were 23.68 ± 13.23 Gy (RA, 24.55 ± 12.51 Gy (HT, 19.82 ± 11.61 Gy (IMRT and 23.56 ± 12.81 Gy (3D CRT, whereas mean dose to rectum was 36.85 ± 12.92 Gy (RA, 33.18 ± 11.12 Gy (HT, IMRT and 38.67 ± 12.84 Gy (3D CRT. Conclusion: All studied intensity-modulated techniques yield treatment plans of significantly improved quality when compared with 3D CRT, with HT providing best organs at risk sparing and RA being the most efficient treatment option, reducing treatment time to 1.45-3.7 min and monitor unit to <400 for a 2 Gy fraction.

  3. Radioprotection of the rat parotid gland by cAMP

    International Nuclear Information System (INIS)

    Sodicoff, M.; Conger, A.D.

    1983-01-01

    Most earlier studies showing a radioprotective effect by cAMP show only slight degrees of protection. The present study demonstrates a substantial protective effect (DMF, 1.63) of exogenously administered cAMP on the rat parotid gland and supports the mechanism suggested previously for protection afforded the parotid glands by the β-adrenergic agonist isoproterenol, which is known to elevate endogenous intracellular cAMP

  4. Parotid carcinoma

    DEFF Research Database (Denmark)

    Godballe, Christian; Schultz, Joyce H; Krogdahl, Annelise

    2003-01-01

    -year recurrence-free survival of the entire study group was 63%, disease-specific survival was 69%, and crude survival was 52%. In univariate analysis, tumor size, histological appearance, T status, stage, the presence of lymph node metastases, distant metastases, pain, and facial nerve dysfunction had...... a significant influence on survival. CONCLUSIONS: A thorough histological revision is pivotal in retrospective parotid carcinoma studies, and tumor size; histological appearance; T, N, and M status; stage; facial nerve dysfunction; and pain from the face and/or neck seem to be significant prognostic indicators...

  5. Position modification and actual radiation dose in parotids for head and neck cancers treated with TomoTherapy

    International Nuclear Information System (INIS)

    Jiang Huayong; Zhang Yongqian; Wang Yadi; Xu Weidong; Gao Junmao; Zhang Fuli; Yao Bo

    2014-01-01

    Objective: To analyze the impact of parotid's position and volume changing on radiation dose for head and neck cancer treated with TomoTherapy. Methods: Totally 12 patients with head and neck cancer were treated with TomoTherapy. Before the treatment, the dose distribution was recalculated with MVCT images, which would obtain the parameters of position, volume and actual radiation dose for parotids. Results: The volume of parotids in Plan2 was significantly lower than in Plan1, and the percentage reduction was 29.06% and 31.78% for left and right parotid, respectively (Z = 6.77, 3.06, P < 0.05). Distance between the COM(center of mass) of parotids and the midline of body was significantly smaller in Plan2 than in Plan1, and the percentage reduction was 6.72% and 6.19% (t = 5.14, 5.80, P < 0.05) at left and right side, respectively. Average dose and V_2_6 for both parotids were higher than those in Plan1, increasing by an average of 37.74%, 25.08% (Z = -6.03, -5.31, P < 0.05) for left parotid and 30.45%, 19.33% (Z = -5.43, -3.26, P < 0.05) for right parotid, respectively. Conclusions: The actual radiation dose to parotids was significantly increased during the radiation therapy for patients with head and neck cancer. There was a linear correlation between the decrease of distance between the COM of parotids and the midline of body and the percentage increase of parotids' radiation dose. No correlation between the reduction of parotids' volume and dose to parotids. In order to reduce the parotids' radiation dose, modification of treatment plan at the appropriate time is essential. (authors)

  6. Adenoid cystic carcinoma associated with mucous retention cyst of the parotid gland.

    Science.gov (United States)

    Hebbale, Manjula Advisha; Halli, Rajshekhar C; Kini, Yogesh K; Kharkar, Viraj R; Metgud, Rashmi

    2011-09-01

    Mucous retention cysts of the parotid gland are rare, and a coexistent adenoid cystic carcinoma is even an unusual occurrence. Such coexistent adenoid cystic carcinomas with mucous retention cyst of the parotid gland are difficult to diagnose clinically and, at times, stage difficulty in their management. We report a rare case of adenoid cystic carcinoma associated with mucous retention cyst of the parotid gland with its diagnostic and management dilemma in a 14-year-old adolescent girl.

  7. SEASONAL VARIATIONS IN HUMAN PAROTID FLUID FLOW RATE IN A SUBTROPICAL CLIMATE.

    Science.gov (United States)

    Parotid fluid was collected under conditions of very minimal stimulation from 3,868 systemically healthy young adult males over a period of two...calendar years. The study was carried out in a subtropical climate in which the only thermal discomfort resulted from the summer heat. Parotid flow rate...fall. During the summer months the mean rate of parotid flow was 0.031 ml./minute; during the winter the flow rate mean increased by 35% to 0.042 ml

  8. Carotid-Sparing Intensity-Modulated Radiotherapy for Early-Stage Squamous Cell Carcinoma of the True Vocal Cord

    International Nuclear Information System (INIS)

    Chera, Bhishamjit S.; Amdur, Robert J.; Morris, Christopher G.; Mendenhall, William M.

    2010-01-01

    Purpose: To compare radiation doses to carotid arteries among various radiotherapy techniques for treatment of early-stage squamous cell carcinoma (SCC) of the true vocal cords. Methods and Materials: Five patients were simulated using computed tomography (CT). Clinical and planning target volumes (PTV) were created for bilateral and unilateral stage T1 vocal cord cancers. Planning risk volumes for the carotid arteries and spinal cord were delineated. For each patient, three treatment plans were designed for bilateral and unilateral target volumes: opposed laterals (LATS), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT), for a total of 30 plans. More than 95% of the PTV received the prescription dose (63Gy at 2.25 Gy per treatment). Results: Carotid dose was lowest with IMRT. With a bilateral vocal cord target, the median carotid dose was 10Gy with IMRT vs. 25 Gy with 3DCRT and 38 Gy with LATS (p < 0.05); with a unilateral target, the median carotid dose was 4 Gy with IMRT vs. 19 Gy with 3DCRT and 39 Gy with LATS (p < 0.05). The dosimetric tradeoff with IMRT is a small area of high dose in the PTV. The worst heterogeneity results were at a maximum point dose of 80 Gy (127%) in a unilateral target that was close to the carotid. Conclusions: There is no question that IMRT can reduce the dose to the carotid arteries in patients with early-stage vocal cord cancer. The question is whether the potential advantage of reducing the carotid dose outweighs the risk of tumor recurrence due to contouring errors and organ motion and the risk of complications from dose heterogeneity.

  9. Dosimetric analysis of testicular doses in prostate intensity-modulated and volumetric-modulated arc radiation therapy at different energy levels

    Energy Technology Data Exchange (ETDEWEB)

    Onal, Cem, E-mail: hcemonal@hotmail.com; Arslan, Gungor; Dolek, Yemliha; Efe, Esma

    2016-01-01

    The aim of this study is to evaluate the incidental testicular doses during prostate radiation therapy with intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc radiotherapy (VMAT) at different energies. Dosimetric data of 15 patients with intermediate-risk prostate cancer who were treated with radiotherapy were analyzed. The prescribed dose was 78 Gy in 39 fractions. Dosimetric analysis compared testicular doses generated by 7-field intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy with a single arc at 6, 10, and 15 MV energy levels. Testicular doses calculated from the treatment planning system and doses measured from the detectors were analyzed. Mean testicular doses from the intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy per fraction calculated in the treatment planning system were 16.3 ± 10.3 cGy vs 21.5 ± 11.2 cGy (p = 0.03) at 6 MV, 13.4 ± 10.4 cGy vs 17.8 ± 10.7 cGy (p = 0.04) at 10 MV, and 10.6 ± 8.5 cGy vs 14.5 ± 8.6 cGy (p = 0.03) at 15 MV, respectively. Mean scattered testicular doses in the phantom measurements were 99.5 ± 17.2 cGy, 118.7 ± 16.4 cGy, and 193.9 ± 14.5 cGy at 6, 10, and 15 MV, respectively, in the intensity-modulated radiotherapy plans. In the volumetric-modulated arc radiotherapy plans, corresponding testicular doses per course were 90.4 ± 16.3 cGy, 103.6 ± 16.4 cGy, and 139.3 ± 14.6 cGy at 6, 10, and 15 MV, respectively. In conclusions, this study was the first to measure the incidental testicular doses by intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy plans at different energy levels during prostate-only irradiation. Higher photon energy and volumetric-modulated arc radiotherapy plans resulted in higher incidental testicular doses compared with lower photon energy and intensity-modulated radiotherapy plans.

  10. Modification of parotids in case of conformal ORL irradiation

    International Nuclear Information System (INIS)

    Louvel, G.; Lafond, C.; Manens, J.P.; Jouyaux, F.; Williaume, D.; Le Prise, E.; Crevoisier, R. de; Cazoulat, G.; Simon, A.; Haigron, P.

    2009-01-01

    The objective of the study is to analyze the anatomical modifications of the parotids in case of tumors irradiation of the O.R.L. area. In case of irradiation of the O.R.L. area the parotids reduce about one third of their volume, by moving inwards and backwards. The dose received by these glands at the end of irradiation can be different from this one initially planned. (N.C.)

  11. Caso clínico: Un tratamiento alternativo a la parotiditis crónica

    OpenAIRE

    Arregui V,Rodrigo; Tamblay N,Natalia; Esquivel C,Patricia

    2008-01-01

    La parotiditis crónica conocida también como parotiditis juvenil recurrente, se define como la inflamación recurrente de la glándula parótida, asociada a la aparición de sialectasias o dilataciones no obstructivas de los conductos glandulares. Como tratamiento se emplea habitualmente la sialografía que tiene una tasa de éxito que va de 62% a 94%. Se presenta aquí un caso de un niño de 4 años de edad con parotiditis crónica, que persiste con episodios de parotiditis, pese a la realización de d...

  12. Features of Parotid Gland Diseases and Surgical Results in Southern Taiwan

    Directory of Open Access Journals (Sweden)

    Wen-Hsiang Chan

    2010-09-01

    Full Text Available Various parotid gland diseases are seen clinically, including inflammation, sialolithiasis, and benign and malignant tumors. It is important to differentiate between these to make a correct diagnosis and for proper management. Here, we investigated the relationship between tumor characteristics and pathology, and considered whether the former could be used to differentiate malignant from benign parotid gland diseases. We retrospectively reviewed the charts and data of 316 patients who underwent surgery in Kaohsiung Medical University Chung-Ho Memorial Hospital from January 1, 1998 to December 31, 2008. Two hundred and eighty-one patients (88.9% had benign disease, and 35 (11.1% had malignant disease. The most common benign disease was pleomorphic adenoma (115 cases, 36.4%, but the most common disease in male patients was Warthin's tumor, a finding which, as far as we aware, has not been previously been reported in the literature. The incidence of Warthin's tumor seems to be increasing. In malignant disease, the most common was acinic cell carcinoma (8 cases, 22.9%. Compared with benign disease, malignant parotid gland disease more often presents as a hard, painful, fixed and large mass (> 3 cm, and more often involves the deep lobe of the parotid gland. Partial parotidectomy was adequate for most tumors, including pleomorphic adenoma. The most common postoperative complication was temporary facial palsy, followed by permanent facial palsy. However, there was no difference in transient facial palsy rate between benign and malignant parotid gland disease, although parotid gland cancer had a higher incidence of permanent facial palsy postoperatively.

  13. [Predictors of malignancy in the management of parotid tumors: about 76 cases].

    Science.gov (United States)

    Bouaity, Brahim; Darouassi, Youssef; Chihani, Mehdi; Touati, Mohamed Mliha; Ammar, Haddou

    2016-01-01

    Salivary gland tumor pathology is complex and poses a diagnostic and therapeutic problem. A good analysis of predictive factors for malignancy in parotid tumors seems currently necessary for better therapeutic planning. The aim of this study was to investigate the predictive factors for malignancy in parotid tumors through a retrospective study of 76 cases of parotid tumor treated in a service of Otorhinolaryngology and Cervico Facial Surgery of Avicenne military hospital of Marrakech between January 2000 and December 2012. The study involved 40 women and 36 men. The average age was 44 years for benign tumours whereas it was 50 years for malignant tumours. The median of consultation time was 24 months for benign tumors and 16 month for malignant tumours. Swelling in the area of the parotid was always a patient detecting sign. Malignancy is clinically suspected based on pain, facial paralysis, surface structure and deeper structure fixity and on the presence of adenopathy. MRI has become the methodology of choice for evaluating parotid tumors due to its good diagnostic value in the assessment of benignity and malignancy. Fine needle aspiration biopsy has no value unless it is positive. Explorative parotidectomy with extemporaneous anatomopathological examination remains the key to positive diagnosis. Parotid benign tumors represent the most frequent entity (80%) and pleomorphic adenoma remains the predominant histologic type (61%). With regard to malignant tumors, they are rare, mainly dominated by mucoepidermoid carcinomas (6,5%). Surgical treatment is the first choice and it is often associated with lymph node dissection and radiation therapy for malignant tumors. Facial paralysis is the most common complication of parotid surgery.

  14. Noninvasive carcinoma ex pleomorphic adenoma of the parotid gland: A difficult diagnosis on fine needle aspiration

    Directory of Open Access Journals (Sweden)

    Theresa Scognamiglio

    2015-01-01

    Full Text Available Carcinoma ex pleomorphic adenoma (CXPA is a rare epithelial malignancy that arises from a primary or recurrent pleomorphic adenoma (PA. It may be noninvasive (NI or invasive. NI CXPA is extremely rare. Preoperative diagnosis on fine needle aspiration (FNA of CXPA may be difficult and poses a diagnostic challenge to clinicians and pathologists. Herein, we describe the FNA findings of a case of NI-CXPA. A 69-year-old woman presented with rapid enlargement of a stable parotid mass of 25 years. Cytologically, malignant cells were focally associated with metachromatic fibromyxoid matrix that was homogeneous and dense with a vague fibrillary quality. There were cell groups, papillary-like clusters and single malignant cells. The nuclei were pleomorphic with irregularly dispersed chromatin, and the cytoplasm was ill-defined and granular. Nucleoli were small to inconspicuous. Mitoses and necrosis were not seen. Cytological features were not specific for any type of salivary gland carcinoma. The FNA diagnosis was primary high-grade adenocarcinoma of the parotid gland, not otherwise specified. Facial nerve-sparing total parotidectomy was performed, which histologically showed PA interspersed with ducts and nests composed of pleomorphic atypical nuclei surrounded by extensive hyalinization. Single cells were also noted. No capsular infiltration was seen in the entirely sampled tumor. Immunohistochemistry for Ki-67 showed a higher proliferation rate in the malignant ducts and p63 positive cells focally surrounded some of the malignant ducts. Histological diagnosis was NI-CXPA. Accurate diagnosis is important for proper surgical management; however, the preoperative diagnosis of NI-CXPA is difficult to make on FNA.

  15. Noninvasive carcinoma ex pleomorphic adenoma of the parotid gland: A difficult diagnosis on fine needle aspiration

    Science.gov (United States)

    Scognamiglio, Theresa; Joshi, Rohan; Kuhel, William I.; Tabbara, Sana O.; Rezaei, M. Katayoon; Hoda, Rana S.

    2015-01-01

    Carcinoma ex pleomorphic adenoma (CXPA) is a rare epithelial malignancy that arises from a primary or recurrent pleomorphic adenoma (PA). It may be noninvasive (NI) or invasive. NI CXPA is extremely rare. Preoperative diagnosis on fine needle aspiration (FNA) of CXPA may be difficult and poses a diagnostic challenge to clinicians and pathologists. Herein, we describe the FNA findings of a case of NI-CXPA. A 69-year-old woman presented with rapid enlargement of a stable parotid mass of 25 years. Cytologically, malignant cells were focally associated with metachromatic fibromyxoid matrix that was homogeneous and dense with a vague fibrillary quality. There were cell groups, papillary-like clusters and single malignant cells. The nuclei were pleomorphic with irregularly dispersed chromatin, and the cytoplasm was ill-defined and granular. Nucleoli were small to inconspicuous. Mitoses and necrosis were not seen. Cytological features were not specific for any type of salivary gland carcinoma. The FNA diagnosis was primary high-grade adenocarcinoma of the parotid gland, not otherwise specified. Facial nerve-sparing total parotidectomy was performed, which histologically showed PA interspersed with ducts and nests composed of pleomorphic atypical nuclei surrounded by extensive hyalinization. Single cells were also noted. No capsular infiltration was seen in the entirely sampled tumor. Immunohistochemistry for Ki-67 showed a higher proliferation rate in the malignant ducts and p63 positive cells focally surrounded some of the malignant ducts. Histological diagnosis was NI-CXPA. Accurate diagnosis is important for proper surgical management; however, the preoperative diagnosis of NI-CXPA is difficult to make on FNA. PMID:25972908

  16. SU-E-T-124: Dosimetric Comparison of HDR Brachytherapy and Intensity Modulated Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Wu, J [Purdue University, West Lafayette, IN (United States); Wu, H [IUPUI, Indianapolis, IN (United States); Das, I [Indiana University- School of Medicine, Indianapolis, IN (United States)

    2014-06-01

    Purpose: Brachytherapy is known to be able to deliver more radiation dose to tumor while minimizing radiation dose to surrounding normal tissues. Proton therapy also provides superior dose distribution due to Bragg peak. Since both HDR and Intensity Modulated Proton Therapy (IMPT) are beneficial for their quick dose drop off, our goal in this study is to compare the pace of dose gradient drop-off between HDR and IMPT plans based on the same CT image data-set. In addition, normal tissues sparing were also compared among HDR, IMPT and SBRT. Methods: Five cervical cancer cases treated with EBRT + HDR boost combination with Tandem and Ovoid applicator were used for comparison purpose. Original HDR plans with prescribed dose of 5.5 Gy x 5 fractions were generated and optimized. The 100% isodose line of HDR plans was converted to a dose volume, and treated as CTV for IMPT and SBRT planning. The same HDR CT scans were also used for IMPT plan and SBRT plan for direct comparison. The philosophy of the IMPT and SBRT planning was to create the same CTV coverage as HDR plans. All three modalities treatment plans were compared to each other with a set of predetermined criteria. Results: With similar target volume coverage in cervix cancer boost treatment, HDR provides a slightly sharper dose drop-off from 100% to 50% isodose line, averagely in all directions compared to IMPT. However, IMPT demonstrated more dose gradient drop-off at the junction of the target and normal tissues by providing more normal tissue sparing and superior capability to reduce integral dose. Conclusion: IMPT is capable of providing comparable dose drop-off as HDR. IMPT can be explored as replacement for HDR brachytherapy in various applications.

  17. Intensity-modulated radiotherapy in patients with locally advanced rectal cancer reduces volume of bowel treated to high dose levels

    International Nuclear Information System (INIS)

    Urbano, M. Teresa Guerrero; Henrys, Anthony J.; Adams, Elisabeth J.; Norman, Andrew R.; Bedford, James L.; Harrington, Kevin J.; Nutting, Christopher M.; Dearnaley, David P.; Tait, Diana M.

    2006-01-01

    Purpose: To investigate the potential for intensity-modulated radiotherapy (IMRT) to spare the bowel in rectal tumors. Methods and Materials: The targets (pelvic nodal and rectal volumes), bowel, and bladder were outlined in 5 patients. All had conventional, three-dimensional conformal RT and forward-planned multisegment three-field IMRT plans compared with inverse-planned simultaneous integrated boost nine-field equally spaced IMRT plans. Equally spaced seven-field and five-field and five-field, customized, segmented IMRT plans were also evaluated. Results: Ninety-five percent of the prescribed dose covered at least 95% of both planning target volumes using all but the conventional plan (mean primary and pelvic planning target volume receiving 95% of the prescribed dose was 32.8 ± 13.7 Gy and 23.7 ± 4.87 Gy, respectively), reflecting a significant lack of coverage. The three-field forward planned IMRT plans reduced the volume of bowel irradiated to 45 Gy and 50 Gy by 26% ± 16% and 42% ± 27% compared with three-dimensional conformal RT. Additional reductions to 69 ± 51 cm 3 to 45 Gy and 20 ± 21 cm 3 to 50 Gy were obtained with the nine-field equally spaced IMRT plans-64% ± 11% and 64% ± 20% reductions compared with three-dimensional conformal RT. Reducing the number of beams and customizing the angles for the five-field equally spaced IMRT plan did not significantly reduce bowel sparing. Conclusion: The bowel volume irradiated to 45 Gy and 50 Gy was significantly reduced with IMRT, which could potentially lead to less bowel toxicity. Reducing the number of beams did not reduce bowel sparing and the five-field customized segmented IMRT plan is a reasonable technique to be tested in clinical trials

  18. Quality of Intensity Modulated Radiation Therapy Treatment Plans Using a 60Co Magnetic Resonance Image Guidance Radiation Therapy System

    International Nuclear Information System (INIS)

    Wooten, H. Omar; Green, Olga; Yang, Min; DeWees, Todd; Kashani, Rojano; Olsen, Jeff; Michalski, Jeff; Yang, Deshan; Tanderup, Kari; Hu, Yanle; Li, H. Harold; Mutic, Sasa

    2015-01-01

    Purpose: This work describes a commercial treatment planning system, its technical features, and its capabilities for creating 60 Co intensity modulated radiation therapy (IMRT) treatment plans for a magnetic resonance image guidance radiation therapy (MR-IGRT) system. Methods and Materials: The ViewRay treatment planning system (Oakwood Village, OH) was used to create 60 Co IMRT treatment plans for 33 cancer patients with disease in the abdominal, pelvic, thorax, and head and neck regions using physician-specified patient-specific target coverage and organ at risk (OAR) objectives. Backup plans using a third-party linear accelerator (linac)-based planning system were also created. Plans were evaluated by attending physicians and approved for treatment. The 60 Co and linac plans were compared by evaluating conformity numbers (CN) with 100% and 95% of prescription reference doses and heterogeneity indices (HI) for planning target volumes (PTVs) and maximum, mean, and dose-volume histogram (DVH) values for OARs. Results: All 60 Co IMRT plans achieved PTV coverage and OAR sparing that were similar to linac plans. PTV conformity for 60 Co was within <1% and 3% of linac plans for 100% and 95% prescription reference isodoses, respectively, and heterogeneity was on average 4% greater. Comparisons of OAR mean dose showed generally better sparing with linac plans in the low-dose range <20 Gy, but comparable sparing for organs with mean doses >20 Gy. The mean doses for all 60 Co plan OARs were within clinical tolerances. Conclusions: A commercial 60 Co MR-IGRT device can produce highly conformal IMRT treatment plans similar in quality to linac IMRT for a variety of disease sites. Additional work is in progress to evaluate the clinical benefit of other novel features of this MR-IGRT system

  19. Ten-year study on varieties of parotid tumors in pediatrics

    International Nuclear Information System (INIS)

    Verdecia Cannizares, Caridad; Cubero Melendez, Osiris; Alonso Pirez, Magda; Portugues Diaz, Andres Manuel

    2011-01-01

    Parotid tumors are uncommon because they account for 0.5 % of all types of cancer in pediatrics. They generally occur as increased local asymptomatic volume, occasionally accompanied by pain and inflammatory signs. A retrospective, longitudinal and descriptive study was carried out to determine the frequency and forms of presentation of parotid tumors diagnosed in 0-18 years-old patients, who had been admitted to the oncological surgery service of 'William Soler' pediatric hospital from February 2001 to December 2010. The variables taken into account were sex, forms of presentation, response to treatment as well as the histological variants presented, with the objective of giving information about these variants of parotid tumors in pediatrics, which, despite their rareness, represent a high risk group when occur. Seven patients were diagnosed, of whom 3 were pleomorphic adenomas, one adenocarcinoma, one mucoepidermoid carcinoma of the gland, one parotid Hodgkin lymphoma and one mixed tumor with atypical cells of the gland. The onset of all the tumors was the presence of a parotid mass in 6 asymptomatic cases and in one case suffering local pain. They were all performed gland ultrasound and aspiration fine needle biopsy. Males prevailed over the females (ratio of 5:2) and the average age of presentation was 12.3 years. Surgery is the main therapeutic weapon in most of cases. It was recommended to closely follow the patients because of their high rate of local recurrence

  20. Feasibility of using intensity-modulated radiotherapy to improve lung sparing in treatment planning for distal esophageal cancer

    International Nuclear Information System (INIS)

    Chandra, Anurag; Guerrero, Thomas M.; Liu, H. Helen; Tucker, Susan L.; Liao Zhongxing; Wang Xiaochun; Murshed, Hasan; Bonnen, Mark D.; Garg, Amit K.; Stevens, Craig W.; Chang, Joe Y.; Jeter, Melinda D.; Mohan, Radhe; Cox, James D.; Komaki, Ritsuko

    2005-01-01

    Background and purpose: To evaluate the feasibility whether intensity-modulated radiotherapy (IMRT) can be used to reduce doses to normal lung than three-dimensional conformal radiotherapy (3DCRT) in treating distal esophageal malignancies. Patients and methods: Ten patient cases with cancer of the distal esophagus were selected for a retrospective treatment-planning study. IMRT plans using four, seven, and nine beams (4B, 7B, and 9B) were developed for each patient and compared with the 3DCRT plan used clinically. IMRT and 3DCRT plans were evaluated with respect to PTV coverage and dose-volumes to irradiated normal structures, with statistical comparison made between the two types of plans using the Wilcoxon matched-pair signed-rank test. Results: IMRT plans (4B, 7B, 9B) reduced total lung volume treated above 10 Gy (V 1 ), 20 Gy (V 2 ), mean lung dose (MLD), biological effective volume (V eff ), and lung integral dose (P 1 , 5% for V 2 , and 2.5 Gy for MLD. IMRT improved the PTV heterogeneity (P<0.05), yet conformity was better with 7B-9B IMRT plans. No clinically meaningful differences were observed with respect to the irradiated volumes of spinal cord, heart, liver, or total body integral doses. Conclusions: Dose-volume of exposed normal lung can be reduced with IMRT, though clinical investigations are warranted to assess IMRT treatment outcome of esophagus cancers

  1. Lymphoma type MALT of the parotid gland

    International Nuclear Information System (INIS)

    Frometa Neirai, Carlos; Gonzalez Gomez, Juan Manuel; Arredondo Lopez, Miguel

    2010-01-01

    The lymphomas type MALT or the mucosa-associated lymphoid tissue, are the most recent variety of non-Hodgkin lymphomas present mainly in the gastric mucosa associated with Helycobacter pylori infection and in the thyroid gland in relation to Hashimoto's thyroiditis. Frequently the origin of this lesion can't be determined only by cytology study, thus it is necessary the histopathology analysis for a definitive diagnosis in most cases. Present paper includes the case of male patient with bilateral volume increase of both parotid glands and a diagnosis cytopathological of a benign lymphoepithelial process and the development of a type MALT lymphoma in relation to the right parotid gland. (author)

  2. Intensity-modulated tangential beam irradiation of the intact breast

    International Nuclear Information System (INIS)

    Hong, L.; Hunt, M.; Chui, C.; Spirou, S.; Forster, K.; Lee, H.; Yahalom, J.; Kutcher, G.J.; McCormick, B.

    1999-01-01

    Purpose: To evaluate the potential benefits of intensity modulated tangential beams in the irradiation of the intact breast. Methods and Materials: Three-dimensional treatment planning was performed on five left and five right breasts using standard wedged and intensity modulated (IM) tangential beams. Optimal beam parameters were chosen using beams-eye-view display. For the standard plans, the optimal wedge angles were chosen based on dose distributions in the central plane calculated without inhomogeneity corrections, according to our standard protocol. Intensity-modulated plans were generated using an inverse planning algorithm and a standard set of target and critical structure optimization criteria. Plans were compared using multiple dose distributions and dose volume histograms for the planning target volume (PTV), ipsilateral lung, coronary arteries, and contralateral breast. Results: Significant improvements in the doses to critical structures were achieved using intensity modulation. Compared with a standard-wedged plan prescribed to 46 Gy, the dose from the IM plan encompassing 20% of the coronary artery region decreased by 25% (from 36 to 27 Gy) for patients treated to the left breast; the mean dose to the contralateral breast decreased by 42% (from 1.2 to 0.7 Gy); the ipsilateral lung volume receiving more than 46 Gy decreased by 30% (from 10% to 7%); the volume of surrounding soft tissue receiving more than 46 Gy decreased by 31% (from 48% to 33%). Dose homogeneity within the target volume improved greatest in the superior and inferior regions of the breast (approximately 8%), although some decrease in the medial and lateral high-dose regions (approximately 4%) was also observed. Conclusion: Intensity modulation with a standard tangential beam arrangement significantly reduces the dose to the coronary arteries, ipsilateral lung, contralateral breast, and surrounding soft tissues. Improvements in dose homogeneity throughout the target volume can also be

  3. Influence of Handheld Mobiles on Parotid: A Cohort Study

    OpenAIRE

    Gracelin E Ranjitha; Ravi David Austin; Sarvathikari Ramasamy; Chinnappa Saravana Bharathi; Deepthi Angeline; Sakthivel Sambasivam

    2017-01-01

    Introduction: Mobile phones generate heat and radiofrequency radiation. The parotid gland is one potential target, because mobile phones are pressed against the side of the face where the gland is located. Aims and Objectives: To compare the effect of mobile phone radiation on parotid gland volume, systolic velocity, salivary flow rate, and protein concentration between the dominant and the nondominant side of mobile phone usage among heavy mobile phone users. Materials and Methods: Ultrasono...

  4. Intensity-modulated radiation therapy for head and neck cancers with bilateral irradiation of the neck: preliminary results

    International Nuclear Information System (INIS)

    Lapeyre, M.; Mege, A.; Mege, P.; Racadot, S.; Marchal, C.; Marchesi, V.; Aletti, P.; Noel, A.; Marchesi, V.; Aletti, P.; Noel, A.; Marchal, C.

    2004-01-01

    Purpose. - To report preliminary results of a prospective study of intensity-modulated radiotherapy (IMRT) for head and neck squamous cell carcinoma (HNC) with bilateral irradiation of the neck. Patients and methods. - At the Alexis Vautrin Cancer Center, 23 patients have been treated with IMRT for HNC since January 2002-August 2003. The first 10 patients with a minimum follow-up of 3 months were analyzed. All tumors were oropharyngeal. There were four females and six males, with a mean age of 50 years (range 39-66). Stages were I-II in eight and III-IV in two. CTV1 was microscopic disease and N0 neck (prescribed dose: 50 Gy) and CTV2 was macroscopic disease and the volume at risk (prescribed dose: 66-70 Gy). PTV were CTV + 5 mm. Patient's immobilization consisted of a five-point head neck shoulder thermoplastic mask. Set-up verifications were done by semi-automatically matching portal images and digitized reconstructed radiographs. IMRT used dynamic multi-leaf collimation. Five patients (group A) received 50 Gy IMRT (two post-operative and three with a brachytherapy boost with a mean dose: 27.5 Gy), and five patients (group B) received 66-70 Gy IMRT (four post-operative). Acute and late normal tissue effects were graded according to the RTOG-EORTC radiation morbidity scoring criteria. Results. - With a median follow-up of 7.4 months (range 3-18.5), no patient died or had loco-regional relapse. The displacements were <4 mm in 98% cases. CTV1 and 2 received 95% of the prescribed dose in 100% of the volume. On average the mean dose to the contralateral parotid was 25.5 Gy for group A vs. 31 Gy for group B (P = 0.09). Mean doses <26 Gy were obtained in three of five patients in group A vs. zero of five patients in group B (P = 0.04). Acute skin toxicities were grade 1 in five patients, grade 2 in four and grade 3 in one. Acute mucositis cases were grade 1 in three patients, grade 2 in five and localized grade 3 in two. At 3 months, 50% of the patients had a grade 0

  5. Diagnosis value of parotid sialography in Sjogren's syndrome

    International Nuclear Information System (INIS)

    Zheng Guo; Zhang Xue; Liu Rongxin; Wang Yali; Zhong Zhicheng; Wang Haiwen

    2006-01-01

    Objective: To study the diagnosis value of parotid sialography in Sjogren's syndrome (SS). Methods: Two hundred and two cases were chosen in the study, 149 cases were SS, 14 cases were chronic parotitis, 2 were parotid benign hypertrophy, and 37 cases were normal. The international classification criteria (2002) for primary Sjogren's syndrome was used to perform the diagnostic test of parotid sialography. Results: In SS, the incidence rate of pathdogical changes of the twiggy canula is the highest (80.20%, 239/298 side), pathological changes of the main canula showed rough fringe(28.19%, 84/298 side), or canula cavity ectasia but not rough fringe(13.09%, 39/298 side), and also can showed mix form of the two kinds of pathological changes, but not often(2.68%, 8/298 side). The branch canula resembled as the main canula in the pathological changes, but observation effect was affected by extensive degree of the twiggy canula in the pathological changes. 0 stage to V stage was seen in SS, the cases with different stage changes in bilateral side were occupied 25.98% (33/127 side). Chronic parotitis had twiggy canula expansion (7/28 side), branch canula expansion (10/28 side), main canula expandsion (11/28 side), but had not the sign of rough fringe. Others of non-SS had no canula pathological changes. Results of the diagnostic test: diagnosis specificity of the branch canula or the main canula rough fringe was 100%, and sensitivity of the twiggy canula expansion and Youden's index were the highest. Conclusion: To diagnose SS as the pathological changes of parotid canula, the twiggy canula expansion was perfect filtration diagnosis criteria, the branch canula and the main canula rough fringe was certain diagnosis criteria. The value of parotid sialography in SS were affected by the form of canula pathological changes and whether two sides examined at the same time. (authors)

  6. Horner’s syndrome associated with parotid duct obstruction in a sheep

    OpenAIRE

    Loste, Araceli; Ramos, Juan J.; Ferrer, Luis M.; Climent, Salvador; Latre, María V.

    2006-01-01

    A 9-year old, Rasa Aragonesa ewe was presented with a left-sided, facial, soft fluctuant swelling. The postmortem examination showed grass awns filling the entire length of the parotid gland duct. The presence of parotid duct obstruction with Horner’s syndrome, previously unreported in sheep, is discussed.

  7. Individual radiation response of parotid glands investigated by dynamic 11C-methionine PET

    International Nuclear Information System (INIS)

    Buus, Simon; Grau, Cai; Munk, Ole Lajord; Rodell, Anders; Jensen, Kenneth; Mouridsen, Kim; Keiding, Susanne

    2006-01-01

    Background and Purpose: Previously, we showed that the net metabolic clearance of 11 C-methionine of the parotid gland, K, calculated from dynamic 11 C-methionine PET, can be used as a measure of parotid gland function. The aim of this study was to investigate by dynamic 11 C-methionine PET the individual radiation dose response relationship of parotid glands in head and neck cancer patients. Patients and methods: Twelve head and neck cancer patients were examined by dynamic 11 C-methionine PET after radiotherapy. Parametric images of K were generated, co-registered and compared voxel-by-voxel with the 3D radiation dose plan within the parotid gland to assess the individual radiation dose-function relationship. Results: In each patient, voxel-values of K decreased with increasing radiation dose. Population based analysis showed a sigmoid dose response relationship of parotid gland, from which we estimated a threshold radiation dose of 16 Gy and a mean TD 5 of 30 Gy. TD 5 ranged from 7 to 50 Gy in the group of patients. Conclusions: Individual radiation dose response of parotid glands can be measured by dynamic 11 C-methionine PET. The dose response analysis revealed a sigmoid relationship, a threshold radiation dose of 16 Gy, and a mean TD 5 of 30 Gy

  8. Contemporary management of benign parotid tumours - the increasing evidence for extracapsular dissection.

    Science.gov (United States)

    Brennan, P A; Ammar, M; Matharu, J

    2017-01-01

    Benign parotid tumours have historically often been managed surgically by superficial parotidectomy. While this approach usually gives a generous cuff of surrounding normal parotid tissue to increase tumour margins, it requires a much larger incision than the increasingly used extracapsular dissection (ECD) technique. Furthermore, superficial parotidectomy can result in marked facial hollowing, Frey syndrome and an increased risk of both temporary and permanent facial nerve weakness. ECD has been popularised as a safe alternative to parotidectomy primarily for the removal of mobile, benign parotid tumours with safe outcomes and reduced risk to the facial nerve. In this article, we review the growing body of evidence for ECD and include our own experience confirming the move away from superficial parotidectomy in contemporary practice for the treatment of benign parotid tumours. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Multifocal Adenomatous Oncocytic Hyperplasia of the Parotid Gland

    Science.gov (United States)

    Kinoshita, Yuichi; Harada, Hiroshi; Kobayashi, Tadao K.; Yoshizawa, Katsuhiko; Yuri, Takashi; Takasu, Kosho; Tsubura, Airo; Shikata, Nobuaki

    2014-01-01

    Multifocal adenomatous oncocytic hyperplasia (MAOH) is a non-neoplastic lesion that is classified as oncocytosis. MAOH is a rare entity of the parotid gland and accounts for approximately 0.1% of salivary gland lesions. Here, we report a case of MAOH of the parotid gland. The patient was a 71-year-old woman who presented with discomfort at the left side of her neck. Fine-needle aspiration cytology of the parotid gland revealed a loose sheet-like cluster of round to polygonal cells with granular cytoplasm against a hemorrhagic background. The cells had round to oval, centrally located nuclei with granular chromatin and without distinct nucleoli. Histologically, the lesion was formed of many variable-sized nodules, comprising oncocyte-like cells with small round nuclei and eosinophilic granular cytoplasm that was positive for mitochondrial antibodies. The diagnosis of MAOH is difficult to make by cytology alone, because the findings overlap with those of other oncocytic lesions. In particular, the cytological findings of MAOH have not been sufficiently reported to date. A correlation of cytology and histology was expected. PMID:25580104

  10. Multifocal Adenomatous Oncocytic Hyperplasia of the Parotid Gland

    Directory of Open Access Journals (Sweden)

    Yuichi Kinoshita

    2014-12-01

    Full Text Available Multifocal adenomatous oncocytic hyperplasia (MAOH is a non-neoplastic lesion that is classified as oncocytosis. MAOH is a rare entity of the parotid gland and accounts for approximately 0.1% of salivary gland lesions. Here, we report a case of MAOH of the parotid gland. The patient was a 71-year-old woman who presented with discomfort at the left side of her neck. Fine-needle aspiration cytology of the parotid gland revealed a loose sheet-like cluster of round to polygonal cells with granular cytoplasm against a hemorrhagic background. The cells had round to oval, centrally located nuclei with granular chromatin and without distinct nucleoli. Histologically, the lesion was formed of many variable-sized nodules, comprising oncocyte-like cells with small round nuclei and eosinophilic granular cytoplasm that was positive for mitochondrial antibodies. The diagnosis of MAOH is difficult to make by cytology alone, because the findings overlap with those of other oncocytic lesions. In particular, the cytological findings of MAOH have not been sufficiently reported to date. A correlation of cytology and histology was expected.

  11. Diagnostic accuracy of ultrasonic histogram features to evaluate radiation toxicity of the parotid glands: a clinical study of xerostomia following head-and-neck cancer radiotherapy.

    Science.gov (United States)

    Yang, Xiaofeng; Tridandapani, Srini; Beitler, Jonathan J; Yu, David S; Chen, Zhengjia; Kim, Sungjin; Bruner, Deborah W; Curran, Walter J; Liu, Tian

    2014-10-01

    To investigate the diagnostic accuracy of ultrasound histogram features in the quantitative assessment of radiation-induced parotid gland injury and to identify potential imaging biomarkers for radiation-induced xerostomia (dry mouth)-the most common and debilitating side effect after head-and-neck radiotherapy (RT). Thirty-four patients, who have developed xerostomia after RT for head-and-neck cancer, were enrolled. Radiation-induced xerostomia was defined by the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer morbidity scale. Ultrasound scans were performed on each patient's parotids bilaterally. The 34 patients were stratified into the acute-toxicity groups (16 patients, ≤ 3 months after treatment) and the late-toxicity group (18 patients, > 3 months after treatment). A separate control group of 13 healthy volunteers underwent similar ultrasound scans of their parotid glands. Six sonographic features were derived from the echo-intensity histograms to assess acute and late toxicity of the parotid glands. The quantitative assessments were compared to a radiologist's clinical evaluations. The diagnostic accuracy of these ultrasonic histogram features was evaluated with the receiver operating characteristic (ROC) curve. With an area under the ROC curve greater than 0.90, several histogram features demonstrated excellent diagnostic accuracy for evaluation of acute and late toxicity of parotid glands. Significant differences (P xerostomia monitoring and assessment. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  12. Dosimetric analysis of the alopecia preventing effect of hippocampus sparing whole brain radiation therapy

    International Nuclear Information System (INIS)

    Mahadevan, Anand; Sampson, Carrie; LaRosa, Salvatore; Floyd, Scott R.; Wong, Eric T.; Uhlmann, Erik J.; Sengupta, Soma; Kasper, Ekkehard M.

    2015-01-01

    Whole brain radiation therapy (WBRT) is widely used for the treatment of brain metastases. Cognitive decline and alopecia are recognized adverse effects of WBRT. Recently hippocampus sparing whole brain radiation therapy (HS-WBRT) has been shown to reduce the incidence of memory loss. In this study, we found that multi-field intensity modulated radiation therapy (IMRT), with strict constraints to the brain parenchyma and to the hippocampus, reduces follicular scalp dose and prevents alopecia. Suitable patients befitting the inclusion criteria of the RTOG 0933 trial received Hippocampus sparing whole brain radiation. On follow up, they were noticed to have full scalp hair preservation. 5 mm thickness of follicle bearing scalp in the radiation field was outlined in the planning CT scans. Conventional opposed lateral WBRT radiation fields were applied to these patient-specific image sets and planned with the same nominal dose of 30 Gy in 10 fractions. The mean and maximum dose to follicle bearing skin and Dose Volume Histogram (DVH) data were analyzed for conventional and HS-WBRT. Paired t-test was used to compare the means. All six patients had fully preserved scalp hair and remained clinically cognitively intact 1–3 months after HS-WBRT. Compared to conventional WBRT, in addition to the intended sparing of the Hippocampus, HS-WBRT delivered significantly lower mean dose (22.42 cGy vs. 16.33 cGy, p < 0.0001), V 24 (9 cc vs. 44 cc, p < 0.0000) and V 30 (9 cc vs. 0.096 cc, p = 0.0106) to follicle hair bearing scalp and prevented alopecia. There were no recurrences in the Hippocampus area. HS-WBRT, with an 11-field set up as described, while attempting to conserve hippocampus radiation and maintain radiation dose to brain inadvertently spares follicle-bearing scalp and prevents alopecia

  13. Multi-institutional Comparison of Intensity Modulated Radiation Therapy (IMRT) Planning Strategies and Planning Results for Nasopharyngeal Cancer

    Science.gov (United States)

    Park, Sung Ho; Park, Suk Won; Oh, Do Hoon; Choi, Youngmin; Kim, Jeung Kee; Ahn, Yong Chan; Park, Won; Suh, Hyun Sook; Lee, Rena; Bae, Hoonsik

    2009-01-01

    The intensity-modulated radiation therapy (IMRT) planning strategies for nasopharyngeal cancer among Korean radiation oncology facilities were investigated. Five institutions with IMRT planning capacity using the same planning system were invited to participate in this study. The institutions were requested to produce the best plan possible for 2 cases that would deliver 70 Gy to the planning target volume of gross tumor (PTV1), 59.4 Gy to the PTV2, and 51.5 Gy to the PTV3 in which elective irradiation was required. The advised fractionation number was 33. The planning parameters, resultant dose distributions, and biological indices were compared. We found 2-3-fold variations in the volume of treatment targets. Similar degree of variation was found in the delineation of normal tissue. The physician-related factors in IMRT planning had more influence on the plan quality. The inhomogeneity index of PTV dose ranged from 4 to 49% in Case 1, and from 5 to 46% in Case 2. Variation in tumor control probabilities for the primary lesion and involved LNs was less marked. Normal tissue complication probabilities for parotid glands and skin showed marked variation. Results from this study suggest that greater efforts in providing training and continuing education in terms of IMRT planning parameters usually set by physician are necessary for the successful implementation of IMRT. PMID:19399266

  14. Evaluation of an automatic segmentation algorithm for definition of head and neck organs at risk.

    Science.gov (United States)

    Thomson, David; Boylan, Chris; Liptrot, Tom; Aitkenhead, Adam; Lee, Lip; Yap, Beng; Sykes, Andrew; Rowbottom, Carl; Slevin, Nicholas

    2014-08-03

    The accurate definition of organs at risk (OARs) is required to fully exploit the benefits of intensity-modulated radiotherapy (IMRT) for head and neck cancer. However, manual delineation is time-consuming and there is considerable inter-observer variability. This is pertinent as function-sparing and adaptive IMRT have increased the number and frequency of delineation of OARs. We evaluated accuracy and potential time-saving of Smart Probabilistic Image Contouring Engine (SPICE) automatic segmentation to define OARs for salivary-, swallowing- and cochlea-sparing IMRT. Five clinicians recorded the time to delineate five organs at risk (parotid glands, submandibular glands, larynx, pharyngeal constrictor muscles and cochleae) for each of 10 CT scans. SPICE was then used to define these structures. The acceptability of SPICE contours was initially determined by visual inspection and the total time to modify them recorded per scan. The Simultaneous Truth and Performance Level Estimation (STAPLE) algorithm created a reference standard from all clinician contours. Clinician, SPICE and modified contours were compared against STAPLE by the Dice similarity coefficient (DSC) and mean/maximum distance to agreement (DTA). For all investigated structures, SPICE contours were less accurate than manual contours. However, for parotid/submandibular glands they were acceptable (median DSC: 0.79/0.80; mean, maximum DTA: 1.5 mm, 14.8 mm/0.6 mm, 5.7 mm). Modified SPICE contours were also less accurate than manual contours. The utilisation of SPICE did not result in time-saving/improve efficiency. Improvements in accuracy of automatic segmentation for head and neck OARs would be worthwhile and are required before its routine clinical implementation.

  15. Emotional Intensity Modulates the Integration of Bimodal Angry Expressions: ERP Evidence

    Directory of Open Access Journals (Sweden)

    Zhihui Pan

    2017-06-01

    Full Text Available Integration of information from face and voice plays a central role in social interactions. The present study investigated the modulation of emotional intensity on the integration of facial-vocal emotional cues by recording EEG for participants while they were performing emotion identification task on facial, vocal, and bimodal angry expressions varying in emotional intensity. Behavioral results showed the rates of anger and reaction speed increased as emotional intensity across modalities. Critically, the P2 amplitudes were larger for bimodal expressions than for the sum of facial and vocal expressions for low emotional intensity stimuli, but not for middle and high emotional intensity stimuli. These findings suggested that emotional intensity modulates the integration of facial-vocal angry expressions, following the principle of Inverse Effectiveness (IE in multimodal sensory integration.

  16. Primary parotid gland lymphoma: a case report

    Directory of Open Access Journals (Sweden)

    Paraskevas Katsaronis

    2011-08-01

    Full Text Available Abstract Introduction Mucosa associated lymphoid tissue lymphomas are the most common lymphomas of the salivary glands. The benign lymphoepithelial lesion is also a lymphoproliferative disease that develops in the parotid gland. In the present case report, we describe one case of benign lymphoepithelial lesion with a subsequent low transformation to grade mucosa associated lymphoid tissue lymphoma appearing as a cystic mass in the parotid gland. Case presentation A 78-year-old Caucasian female smoker was referred to our clinic with a non-tender left facial swelling that had been present for approximately three years. The patient underwent resection of the left parotid gland with preservation of the left facial nerve through a preauricular incision. The pathology report was consistent with a low-grade marginal-zone B-cell non-Hodgkin lymphoma (mucosa associated lymphoid tissue lymphoma following benign lymphoepithelial lesion of the gland. Conclusions Salivary gland mucosa associated lymphoid tissue lymphoma should be considered in the differential diagnosis of cystic or bilateral salivary gland lesions. Parotidectomy is recommended in order to treat the tumor and to ensure histological diagnosis for further follow-up planning. Radiotherapy and chemotherapy should be considered in association with surgery in disseminated forms or after removal.

  17. SU-F-T-195: Systematic Constraining of Contralateral Parotid Gland Led to Improved Dosimetric Outcomes for Multi-Field Optimization with Scanning Beam Proton Therapy: Promising Results From a Pilot Study in Patients with Base of Tongue Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Wu, R; Liu, A; Poenisch, F; Palmer, M; Gillin, M; Zhu, X [Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX (United States); Crowford, C; Georges, R; Amin, M [Department of Medical Dosimetry, MD Anderson Cancer Ctr, Houston, TX (United States); Sio, T; Gunn, B; Frank, S [Radiation Oncology Department MD Anderson Cancer Ctr, Houston, TX (United States)

    2016-06-15

    Purpose: Treatment planning for Intensity Modulated Proton Therapy (IMPT) for head and neck cancer is time-consuming due to the large number of organs-at-risk (OAR) to be considered. As there are many competing objectives and also wide range of acceptable OAR constraints, the final approved plan may not be most optimal for the given structures. We evaluated the dose reduction to the contralateral parotid by implementing standardized constraints during optimization for scanning beam proton therapy planning. Methods: Twenty-four (24) consecutive patients previously treated for base of tongue carcinoma were retrospectively selected. The doses were 70Gy, 63Gy and 57Gy (SIB in 33 fractions) for high-, intermediate-, and standard-risk clinical target volumes (CTV), respectively; the treatment included bilateral neck. Scanning beams using MFO with standardized bilateral anterior oblique and PA fields were applied. New plans where then developed and optimized by employing additional contralateral parotid constraints at multiple defined dose levels. Using a step-wise iterative process, the volume-based constraints at each level were then further reduced until known target coverages were compromised. The newly developed plans were then compared to the original clinically approved plans using paired student t-testing. Results: All 24 newly optimized treatment plans maintained initial plan quality as compared to the approved plans, and the 98% prescription dose coverage to the CTV’s were not compromised. Representative DVH comparison is shown in FIGURE 1. The contralateral parotid doses were reduced at all levels of interest when systematic constraints were applied to V10, V20, V30 and V40Gy (All P<0.0001; TABLE 1). Overall, the mean contralateral parotid doses were reduced by 2.26 Gy on average, a ∼13% relative improvement. Conclusion: Applying systematic and volume-based contralateral parotid constraints for IMPT planning significantly reduced the dose at all dosimetric

  18. MIMO Intensity-Modulation Channels: Capacity Bounds and High SNR Characterization

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2016-01-01

    The capacity of MIMO intensity modulation channels is studied. The nonnegativity of the transmit signal (intensity) poses a challenge on the precoding of the transmit signal, which limits the applicability of classical schemes in this type

  19. Unexpected Detection of Parotid Gland Malignancy during Primary Extracapsular Dissection

    OpenAIRE

    Mantsopoulos, Konstantinos; Velegrakis, Stylianos; Iro, Heinrich

    2015-01-01

    Objective To evaluate the oncologic and functional outcome in cases in which a false preoperative working hypothesis “benign parotid tumor” led to a primary extracapsular dissection being performed rather than a traditional, more radical surgical modality. Study Design Case series with chart review. Setting Academic tertiary referral center. Subjects and Methods The records of all patients treated for malignant tumors of the parotid gland between 2006 and 2012 were...

  20. Malignant tumor of the parotid gland with metastasis into the cervical vertebra

    International Nuclear Information System (INIS)

    Kimura, Jun; Tsuchiya, Keiichi; Utsumi, Takehiko; Furuki, Shin; Asano, Hisashi.

    1979-01-01

    A patient with malignant tumor of the parotid gland with metastasis into the cervical vertebra was found. Because spinal symptoms were observed at first and the symptoms and the course of the disease were not typical, it was so difficult to diagnose it. For this patient, a parotid gland scintigram with sup(99m)Tc was very useful to diagnose the lesion. The patient was treated with chemotherapy, 60 Co beam therapy and immuno-chemo-therapy and survived about one year and two months more. Cyclo-C (cyclocytidine) was very effective to control the primary lesion in the parotid gland. (Nishio, M.)

  1. Adrenal status assessed by direct radioimmunoassay of cortisol in whole saliva or parotid saliva

    International Nuclear Information System (INIS)

    Walker, R.F.; Riad-Fahmy, D.; Read, G.F.

    1978-01-01

    We describe a direct radioimmunoassay for cortisol in 10-μl volumes of parotid saliva or whole saliva. Binding proteins are absent from these fluids, as demonstrated by the excellent correlation between results for samples assayed directly and by a comparison procedure involving extraction with 1,2-dichloroethane. The direct assay is specific, precise, and had a lower limit of sensitivity of 4 pg per assay tube. Comparison of cortisol concentrations in plasma, parotid saliva, and whole saliva in persons undergoing investigations for assessing adrenal function, including stimulation with cosyntropin (Synachthen) and suppression with dexamethasone, indicated that changes in plasma cortisol concentration were accurately and immediately reflected in saliva from either the parotid-gland or whole saliva. A marked circadian rhythm has also been demonstrated for cortisol in parotid-gland saliva and whole saliva. We had to modify the 1,2-dichloroethane extraction procedure for accurate determination of cortisol in parotid saliva and whole saliva of patients undergoing treatment with metyrapone

  2. Pump-to-Signal Intensity Modulation Transfer in Saturated- Gain Fiber Optical Parametric Amplifiers

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Lund-Hansen, Toke; Rottwitt, Karsten

    2011-01-01

    The pump-to-signal intensity modulation transfer in saturated degenerate FOPAs is numerically investigated over the whole gain bandwidth. The intensity modulation transfer decreases and the OSNR improves when the amplifier operates in the saturation regime....

  3. [Lupus erythematosus panniculitis presenting as palpebral edema and parotiditis].

    Science.gov (United States)

    Pérez-Pastor, G; Valcuende, F; Tomás, G; Moreno, M

    2007-10-01

    Lupus erythematosus panniculitis or lupus erythematosus profundus is characterized by inflammation of the deep dermis and subcutaneous tissue. It can occur in isolation or associated with chronic systemic or discoid lupus erythematosus. It usually consists of nodules and hardened subcutaneous plaques on the forehead, cheeks, proximal extremities, and buttocks. Periorbital and parotid involvement are rare and can lead to misdiagnosis. We present the case of a patient with lupus erythematosus panniculitis who presented with palpebral edema and involvement of the periocular fat and parotid gland.

  4. The pitfalls of dosimetric commissioning for intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Tohyama, Naoki; Kodama, Takashi; Hatano, K.

    2013-01-01

    Intensity modulated radiation therapy (IMRT) allows higher radiation dose to be focused to the target volumes while minimizing the dose to OAR. To start of clinical treatment in IMRTvwe must perform commissioning strictly than 3D-conformal radiotherapy (CRT). In this report, pitfalls of dosimetric commissioning for intensity modulated radiation therapy were reviewed. Multileaf collimator (MLC) offsets and MLC transmissions are important parameters in commissioning of RTPS for IMRT. Correction of depth scaling and fluence scaling is necessary for dose measurement using solid phantom. (author)

  5. Differential Diagnosis of Parotid Lipoma in a Breast Ca Patient

    Directory of Open Access Journals (Sweden)

    Melda Misirlioglu

    2017-01-01

    Full Text Available Lipomas are common benign tumors usually detected on the torso, neck, upper thighs, and upper arms. However, they are rarely found in the parotid gland region. Because of their rarity at this site, they are not often considered in the differential diagnosis of parotid tumors. This report describes a rare case of a lipoma in the superficial lobe of parotid gland. A 71-year-old female patient admitted to our department complaining about swelling and pain in the posterior area of the left mandibular region since one month. Her medical history included mastectomy after breast CA fifteen years ago. Clinical examination revealed a smooth-surfaced, soft, and painful mass, with well-defined margins in the left mandibular region. Differential diagnosis of metastasis, inflammatory neck swellings, and benign salivary gland tumors were considered for the patient. Advanced imaging methods such as ultrasonography and contrast tomography revealed that the lesion was a lipoma of parotid gland. A surgical intervention under general anesthesia was planned for the removal of the mass; however patient refused the surgical treatment. Patient was placed on six-month periodic recall. This article reviews the radiographic appearance and differential diagnoses of lipoma in this rare location.

  6. Head and neck cancers: clinical benefits of three-dimensional conformal radiotherapy and of intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Giraud, P.; Jaulerry, C.; Brunin, F.; Zefkili, S.; Helfre, S.; Chauvet, I.; Rosenwald, J.C.; Cosset, J.M.

    2002-01-01

    The conformal radiotherapy approach, three-dimensional conformal radiotherapy (3DCRT) or intensity-modulated radiotherapy (IMRT), is based on modern imaging modalities, efficient 3-D treatment planning systems, sophisticated immobilization systems and rigorous quality assurance and treatment verification. The central objective of conformal radiotherapy is to ensure a high dose distribution tailored to the limits of the target volume while reducing exposure of normal tissues. These techniques would then allow further tumor dose escalation. Head-and-neck tumors are some of the most attractive localizations to test conformal radiotherapy. They combine ballistic difficulties due to particularly complex shapes (nasopharynx, ethmoid) and problems due to the number and low tolerance of neighbouring organs like parotids, eyes, brainstem and spinal cord. The therapeutic irradiation of head-and-neck tumors thus remains a challenge for the radiation oncologist. Conformal radiotherapy does have a significant potential for improving local control and reducing toxicity when compared to standard radiotherapy. However, in the absence of prospective randomized trials, it is somewhat difficult at present to evaluate the real benefits drawn from 3DCRT and IMRT. The published clinical reports on the use of conformal radiotherapy are essentially dealing with dosimetric comparisons on relatively small numbers of patients. Recently, a few publications have emphasized the clinical experience several precursor teams with a suitable follow-up. This paper describes the current state-of-the-art of 3DCRT and IMRT in order to evaluate the impact of these techniques on head-and-neck cancers irradiation. (authors)

  7. Comparison of intensity-modulated radiotherapy and volumetric-modulated arc therapy dose measurement for head and neck cancer using optical stimulated luminescence dosimeter

    International Nuclear Information System (INIS)

    Lai, Lu-Han; Chuang, Keh-Shih; Lin, Hsin-Hon; Liu, Yi-Chi; Kuo, Chiung-Wen; Lin, Jao-Perng

    2017-01-01

    The in-vivo dose distributions of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), a newly developed technique, for head and neck cancer have been investigated for several years. The present study used a head-and-neck RANDO phantom to simulate the clinical conditions of nasopharyngeal carcinoma and compare the radiation doses between VMAT and IMRT. Three types of planning target volume (PTV) profiles were targeted by reducing the PTV surface margin by 0, 3, and 5 mm. An optically stimulated luminescence dosimeter was used to measure the surface doses. The results revealed that VMAT provided on average 16.8–13.8% lower surface doses within the PTV target areas than IMRT. When the PTV margin was reduced by 0 mm, the surface doses for IMRT reached their maximum value, accounting for 75.1% of its prescribed dose (Dp); however, the Dp value of VMAT was only 61.1%. When the PTV margin was reduced by 3 or 5 mm, the surface doses decreased considerably. The observed surface doses were insufficient when the tumours invaded the body surface; however, VMAT exerted larger skin-sparing effects than IMRT when the tumours away from the skin. These results suggest that the skin doses for these two techniques are insufficient for surface tumours. Notably, VMAT can provide lower skin doses for deep tumours. - Highlights: • The surface doses of NPC patients are compared between VMAT and IMRT. • VMAT exerts lower skin dose than IMRT for deep tumours. • The surface tumour coverage is insufficient for VMAT and IMRT.

  8. Direct-aperture optimization applied to selection of beam orientations in intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Bedford, J L; Webb, S

    2007-01-01

    Direct-aperture optimization (DAO) was applied to iterative beam-orientation selection in intensity-modulated radiation therapy (IMRT), so as to ensure a realistic segmental treatment plan at each iteration. Nested optimization engines dealt separately with gantry angles, couch angles, collimator angles, segment shapes, segment weights and wedge angles. Each optimization engine performed a random search with successively narrowing step sizes. For optimization of segment shapes, the filtered backprojection (FBP) method was first used to determine desired fluence, the fluence map was segmented, and then constrained direct-aperture optimization was used thereafter. Segment shapes were fully optimized when a beam angle was perturbed, and minimally re-optimized otherwise. The algorithm was compared with a previously reported method using FBP alone at each orientation iteration. An example case consisting of a cylindrical phantom with a hemi-annular planning target volume (PTV) showed that for three-field plans, the method performed better than when using FBP alone, but for five or more fields, neither method provided much benefit over equally spaced beams. For a prostate case, improved bladder sparing was achieved through the use of the new algorithm. A plan for partial scalp treatment showed slightly improved PTV coverage and lower irradiated volume of brain with the new method compared to FBP alone. It is concluded that, although the method is computationally intensive and not suitable for searching large unconstrained regions of beam space, it can be used effectively in conjunction with prior class solutions to provide individually optimized IMRT treatment plans

  9. Frozen section pathology for decision making in parotid surgery.

    Science.gov (United States)

    Olsen, Kerry D; Moore, Eric J; Lewis, Jean E

    2013-12-01

    For parotid lesions, the high accuracy and utility of intraoperative frozen section (FS) pathology, compared with permanent section pathology, facilitates intraoperative decision making about the extent of surgery required. To demonstrate the accuracy and utility of FS pathology of parotid lesions as one factor in intraoperative decision making. Retrospective review of patients undergoing parotidectomy at a tertiary care center. Evaluation of the accuracy of FS pathology for parotid surgery by comparing FS pathology results with those of permanent section. Documented changes from FS to permanent section in 1339 parotidectomy pathology reports conducted from January 1, 2000, through December 31, 2009, included 693 benign and 268 primary and metastatic malignant tumors. Changes in diagnosis were found from benign to malignant (n = 11) and malignant to benign (n = 2). Sensitivity and specificity of a malignant diagnosis were 98.5% and 99.0%, respectively. Other changes were for lymphoma vs inflammation or lymphoma typing (n = 89) and for confirmation of or change in tumor type for benign (n = 36) or malignant (n = 69) tumors. No case changed from low- to high-grade malignant tumor. Only 4 cases that changed from FS to permanent section would have affected intraoperative decision making. Three patients underwent additional surgery 2 to 3 weeks later. Overall, only 1 patient was overtreated (lymphoma initially deemed carcinoma). Frozen section pathology for parotid lesions has high accuracy and utility in intraoperative decision making, facilitating timely complete procedures.

  10. Cardiac Exposure in the Dynamic Conformal Arc Therapy, Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy of Lung Cancer.

    Directory of Open Access Journals (Sweden)

    Xin Ming

    Full Text Available To retrospectively evaluate the cardiac exposure in three cohorts of lung cancer patients treated with dynamic conformal arc therapy (DCAT, intensity-modulated radiotherapy (IMRT, or volumetric modulated arc therapy (VMAT at our institution in the past seven years.A total of 140 lung cancer patients were included in this institutional review board approved study: 25 treated with DCAT, 70 with IMRT and 45 with VMAT. All plans were generated in a same commercial treatment planning system and have been clinically accepted and delivered. The dose distribution to the heart and the effects of tumor laterality, the irradiated heart volume and the beam-to-heart distance on the cardiac exposure were investigated.The mean dose to the heart among all 140 plans was 4.5 Gy. Specifically, the heart received on average 2.3, 5.2 and 4.6 Gy in the DCAT, IMRT and VMAT plans, respectively. The mean heart doses for the left and right lung tumors were 4.1 and 4.8 Gy, respectively. No patients died with evidence of cardiac disease. Three patients (2% with preexisting cardiac condition developed cardiac disease after treatment. Furthermore, the cardiac exposure was found to increase linearly with the irradiated heart volume while decreasing exponentially with the beam-to-heart distance.Compared to old technologies for lung cancer treatment, modern radiotherapy treatment modalities demonstrated better heart sparing. But the heart dose in lung cancer radiotherapy is still higher than that in the radiotherapy of breast cancer and Hodgkin's disease where cardiac complications have been extensively studied. With strong correlations of mean heart dose with beam-to-heart distance and irradiated heart volume, cautions should be exercised to avoid long-term cardiac toxicity in the lung cancer patients undergoing radiotherapy.

  11. Linear accelerator-based intensity-modulated total marrow irradiation technique for treatment of hematologic malignancies: a dosimetric feasibility study.

    Science.gov (United States)

    Yeginer, Mete; Roeske, John C; Radosevich, James A; Aydogan, Bulent

    2011-03-15

    To investigate the dosimetric feasibility of linear accelerator-based intensity-modulated total marrow irradiation (IM-TMI) in patients with hematologic malignancies. Linear accelerator-based IM-TMI treatment planning was performed for 9 patients using the Eclipse treatment planning system. The planning target volume (PTV) consisted of all the bones in the body from the head to the mid-femur, except for the forearms and hands. Organs at risk (OAR) to be spared included the lungs, heart, liver, kidneys, brain, eyes, oral cavity, and bowel and were contoured by a physician on the axial computed tomography images. The three-isocenter technique previously developed by our group was used for treatment planning. We developed and used a common dose-volume objective method to reduce the planning time and planner subjectivity in the treatment planning process. A 95% PTV coverage with the 99% of the prescribed dose of 12 Gy was achieved for all nine patients. The average dose reduction in OAR ranged from 19% for the lungs to 68% for the lenses. The common dose-volume objective method decreased the planning time by an average of 35% and reduced the inter- and intra- planner subjectivity. The results from the present study suggest that the linear accelerator-based IM-TMI technique is clinically feasible. We have demonstrated that linear accelerator-based IM-TMI plans with good PTV coverage and improved OAR sparing can be obtained within a clinically reasonable time using the common dose-volume objective method proposed in the present study. Copyright © 2011. Published by Elsevier Inc.

  12. SU-F-T-198: Dosimetric Comparison of Carbon and Proton Radiotherapy for Recurrent Nasopharynx Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Sheng, Y; Zhao, J; Wang, W; Lin, L; Liu, X; Shahnazi, K [Shanghai Proton and Heavy Ion Center, Shanghai (China)

    2016-06-15

    Purpose: Various radiotherapy planning methods for locally recurrent nasopharynx carcinoma (R-NPC) have been proposed. The purpose of this study was to compare carbon and proton therapy for the treatment of R-NPC in terms of dose coverage for target volume and sparing for organs at risk (OARs). Methods: Six patients who were suffering from R-NPC and treated using carbon therapy were selected for this study. Treatment plans with a total dose of 57.5Gy (RBE) in 23 fractions were made using SIEMENS Syngo V11. An intensity-modulated radiotherapy optimization method was chosen for carbon plans (IMCT) while for proton plans both intensity-modulated radiotherapy (IMPT) and single beam optimization (proton-SBO) methods were chosen. Dose distributions, dose volume parameters, and selected dosimetric indices for target volumes and OARs were compared for all treatment plans. Results: All plans provided comparable PTV coverage. The volume covered by 95% of the prescribed dose was comparable for all three plans. The average values were 96.11%, 96.24% and 96.11% for IMCT, IMPT, and proton-SBO respectively. A significant reduction of the 80% and 50% dose volumes were observed for the IMCT plans compared to the IMPT and proton-SBO plans. Critical organs lateral to the target such as brain stem and spinal cord were better spared by IMPT than by proton-SBO, while IMCT spared those organs best. For organs in the beam path, such as parotid glands, the mean dose results were similar for all three plans. Conclusion: Carbon plans yielded better dose conformity than proton plans. They provided similar or better target coverage while significantly lowering the dose for normal tissues. Dose sparing for critical organs in IMPT plans was better than proton-SBO, however, IMPT is known to be more sensitive to range uncertainties. For proton plans it is essential to find a balance between the two optimization methods.

  13. Parotid abscess due to salmonella enteritidis: A case report.

    Science.gov (United States)

    Reyes, Cesar V; Jensen, JoAnne D

    2006-01-01

    Salmonella infection of the parotid gland is rare. An instance in a 50-year-old man of Salmonella enteritidis parotiditis initially recognized by microbial culture of a fine needle aspiration cytology material is described. The identified predisposing factor was chronic alcoholic abuse. For the infection source, a carrier state of salmonella parotitis was postulated, which progressed to focal abscess and was subsequently complicated by bacteremia and hematogenous spread to the liver, spleen and lungs. Salmonella should be included in the differential consideration of head and neck abscesses in immunocompromised individuals and treated aggressively.

  14. Postoperative radiotherapy for parotid gland malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Eom, Keun Yong; Wu, Hong Gyun; Kim, Jae Sung; Park, Charn Il; Kim, Kwang Hyun; Lee, Chae Seo [Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, In Ah [Bundang Seoul National University Hospital, Seongnam (Korea, Republic of)

    2005-09-15

    The aim of this study was to evaluate the clinical results of postoperative radiotherapy for parotid gland malignancy, and determine prognostic factors for locoregional control and survival. Between 1980 and 2002, 130 patients with parotid malignancy were registered in the database of the Department of Radiation Oncology, Seoul National University Hospital. The subjects of this analysis were the 72 of these 130 patients who underwent postoperative irradiation. There were 42 males and 30 females, with a median age of 46.5 years. The most common histological type was a mucoepidermoid carcinoma. There were 6, 23, 23 and 20 patients in Stages I, II, III and IV, respectively. The median dose to the tumor bed was 60 Gy, with a median fraction size of 1.8 Gy. The overall 5 and 10 year survival rates were 85 and 76%, respectively. The five-year locoregional control rate was 85%, which reached a plateau phase after 6 years. Sex and histological type were found to be statistically significant for overall survival from a multivariate analysis. No other factors, including age, facial nerve palsy and stage, were related to overall survival. For locoregional control, nodal involvement and positive resection margin were associated with poor local control. Histological type, tumor size, perineural invasion and type of surgery were not significant for locoregional control. A high survival rate of parotid gland malignancies, with surgery and postoperative radiotherapy, was confirmed. Sex and histological type were significant prognostic factors for overall survival. Nodal involvement and a positive resection margin were associated with poor locoregional control.

  15. Electroactive subwavelength gratings (ESWGs) from conjugated polymers for color and intensity modulation

    Science.gov (United States)

    Bhuvana, Thiruvelu; Kim, Byeonggwan; Yang, Xu; Shin, Haijin; Kim, Eunkyoung

    2012-05-01

    Subwavelength gratings with electroactive polymers such as poly(3-hexylthiophene) (P3HT) and poly(3,4-propylenedioxythiophene-phenylene) (P(ProDOT-Ph)) controlled the color intensity for various visible colors of diffracted light in a single device. Under the illumination of a white light, at a fixed angle of incidence, the color intensity of the diffracted light was reversibly switched from the maximum value down to 15% (85% decrease) by applying -2 to 2 V due to electrochemical (EC) reaction. All spectral colors including red, green, and blue were generated by changing the angle of incidence, and the intensity of each color was modulated electrochemically at a single EC device. With electroactive subwavelength gratings (ESWGs) of P3HT, the maximum modulation of the color intensity was observed in the red-yellow quadrant in the CIE color plot, whereas for the ESWGs of P(ProDOT-Ph), the maximum modulation of the color intensity was observed in the yellow-green and green-blue quadrants. Both ESWGs showed a memory effect, keeping their color and intensity even after power was turned off for longer than 40 hours.Subwavelength gratings with electroactive polymers such as poly(3-hexylthiophene) (P3HT) and poly(3,4-propylenedioxythiophene-phenylene) (P(ProDOT-Ph)) controlled the color intensity for various visible colors of diffracted light in a single device. Under the illumination of a white light, at a fixed angle of incidence, the color intensity of the diffracted light was reversibly switched from the maximum value down to 15% (85% decrease) by applying -2 to 2 V due to electrochemical (EC) reaction. All spectral colors including red, green, and blue were generated by changing the angle of incidence, and the intensity of each color was modulated electrochemically at a single EC device. With electroactive subwavelength gratings (ESWGs) of P3HT, the maximum modulation of the color intensity was observed in the red-yellow quadrant in the CIE color plot, whereas for the

  16. Modulation instability of an intense laser beam in an unmagnetized ...

    Indian Academy of Sciences (India)

    The modulation instability of an intense circularly polarized laser beam propagating in an unmagnetized, cold electron–positron–ion plasma is investigated. Adopting a generalized Karpman method, a three-dimensional nonlinear equation is shown to govern the laser field. Then the conditions for modulation instability and ...

  17. Parotid lymphomas - clinical and computed tomogrphic imaging ...

    African Journals Online (AJOL)

    Parotid lymphomas - clinical and computed tomogrphic imaging features. ... South African Journal of Surgery ... Lymphoma has a clinical presentation similar ... CT scanning is a useful adjunctive investigation to determine the site and extent of ...

  18. Image-guided total marrow and total lymphatic irradiation using helical tomotherapy

    International Nuclear Information System (INIS)

    Schultheiss, Timothy E.; Wong, Jeffrey; Liu, An; Olivera, Gustavo; Somlo, George

    2007-01-01

    Purpose: To develop a treatment technique to spare normal tissue and allow dose escalation in total body irradiation (TBI). We have developed intensity-modulated radiotherapy techniques for the total marrow irradiation (TMI), total lymphatic irradiation, or total bone marrow plus lymphatic irradiation using helical tomotherapy. Methods and Materials: For TBI, we typically use 12 Gy in 10 fractions delivered at an extended source-to-surface distance (SSD). Using helical tomotherapy, it is possible to deliver equally effective doses to the bone marrow and lymphatics while sparing normal organs to a significant degree. In the TMI patients, whole body skeletal bone, including the ribs and sternum, comprise the treatment target. In the total lymphatic irradiation, the target is expanded to include the spleen and major lymph node areas. Sanctuary sites for disease (brain and testes) are included when clinically indicated. Spared organs include the lungs, esophagus, parotid glands, eyes, oral cavity, liver, kidneys, stomach, small and large intestine, bladder, and ovaries. Results: With TBI, all normal organs received the TBI dose; with TMI, total lymphatic irradiation, and total bone marrow plus lymphatic irradiation, the visceral organs are spared. For the first 6 patients treated with TMI, the median dose to organs at risk averaged 51% lower than would be achieved with TBI. By putting greater weight on the avoidance of specific organs, greater sparing was possible. Conclusion: Sparing of normal tissues and dose escalation is possible using helical tomotherapy. Late effects such as radiation pneumonitis, veno-occlusive disease, cataracts, neurocognitive effects, and the development of second tumors should be diminished in severity and frequency according to the dose reduction realized for the organs at risk

  19. Comparison of Planning Quality and Efficiency Between Conventional and Knowledge-based Algorithms in Nasopharyngeal Cancer Patients Using Intensity Modulated Radiation Therapy

    International Nuclear Information System (INIS)

    Chang, Amy T.Y.; Hung, Albert W.M.; Cheung, Fion W.K.; Lee, Michael C.H.; Chan, Oscar S.H.; Philips, Helen; Cheng, Yung-Tang; Ng, Wai-Tong

    2016-01-01

    Purpose: Intensity modulated radiation therapy (IMRT) is widely used to achieve a highly conformal dose and improve treatment outcome. However, plan quality and planning time are institute and planner dependent, and no standardized tool exists to recognize an optimal plan. RapidPlan, a knowledge-based algorithm, can generate constraints to assist optimization and produce high-quality IMRT plans. This report evaluated the quality and efficiency of using RapidPlan in nasopharyngeal carcinoma (NPC) IMRT planning. Methods and Materials: RapidPlan was configured using 79 radical IMRT plans for NPC; 20 consecutive NPC patients indicated for radical radiation therapy between October 2014 and May 2015 were then recruited to assess its performance. The ability of RapidPlan to produce acceptable plans was evaluated. For plans that could not achieve clinical acceptance, manual touch-up was performed. The IMRT plans produced without RapidPlan (manual plans) and with RapidPlan (RP-2 plans, including those with manual touch-up) were compared in terms of dosimetric quality and planning efficiency. Results: RapidPlan by itself could produce clinically acceptable plans for 9 of the 20 patients; manual touch-up increased the number of acceptable plans (RP-2 plans) to 19. The target dose coverage and conformity were very similar. No difference was found in the maximum dose to the brainstem and optic chiasm. RP-2 plans delivered a higher maximum dose to the spinal cord (46.4 Gy vs 43.9 Gy, P=.002) but a lower dose to the parotid (mean dose to right parotid, 37.3 Gy vs 45.4 Gy; left, 34.4 Gy vs 43.1 Gy; P<.001) and the right cochlea (mean dose, 48.6 Gy vs 52.6 Gy; P=.02). The total planning time for RP-2 plans was significantly less than that for manual plans (64 minutes vs 295 minutes, P<.001). Conclusions: This study shows that RapidPlan can significantly improve planning efficiency and produce quality IMRT plans for NPC patients.

  20. Comparison of Planning Quality and Efficiency Between Conventional and Knowledge-based Algorithms in Nasopharyngeal Cancer Patients Using Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Amy T.Y., E-mail: changty@ha.org.hk [Department of Clinical Oncology, Pamela Youde Nethersole Eastern Hospital (Hong Kong); Hung, Albert W.M. [Department of Clinical Oncology, Pamela Youde Nethersole Eastern Hospital (Hong Kong); Cheung, Fion W.K.; Lee, Michael C.H. [Department of Medical Physics, Pamela Youde Nethersole Eastern Hospital (Hong Kong); Chan, Oscar S.H. [Department of Clinical Oncology, Pamela Youde Nethersole Eastern Hospital (Hong Kong); Philips, Helen; Cheng, Yung-Tang [Varian Medical Systems, Palo Alto, California (United States); Ng, Wai-Tong [Department of Clinical Oncology, Pamela Youde Nethersole Eastern Hospital (Hong Kong)

    2016-07-01

    Purpose: Intensity modulated radiation therapy (IMRT) is widely used to achieve a highly conformal dose and improve treatment outcome. However, plan quality and planning time are institute and planner dependent, and no standardized tool exists to recognize an optimal plan. RapidPlan, a knowledge-based algorithm, can generate constraints to assist optimization and produce high-quality IMRT plans. This report evaluated the quality and efficiency of using RapidPlan in nasopharyngeal carcinoma (NPC) IMRT planning. Methods and Materials: RapidPlan was configured using 79 radical IMRT plans for NPC; 20 consecutive NPC patients indicated for radical radiation therapy between October 2014 and May 2015 were then recruited to assess its performance. The ability of RapidPlan to produce acceptable plans was evaluated. For plans that could not achieve clinical acceptance, manual touch-up was performed. The IMRT plans produced without RapidPlan (manual plans) and with RapidPlan (RP-2 plans, including those with manual touch-up) were compared in terms of dosimetric quality and planning efficiency. Results: RapidPlan by itself could produce clinically acceptable plans for 9 of the 20 patients; manual touch-up increased the number of acceptable plans (RP-2 plans) to 19. The target dose coverage and conformity were very similar. No difference was found in the maximum dose to the brainstem and optic chiasm. RP-2 plans delivered a higher maximum dose to the spinal cord (46.4 Gy vs 43.9 Gy, P=.002) but a lower dose to the parotid (mean dose to right parotid, 37.3 Gy vs 45.4 Gy; left, 34.4 Gy vs 43.1 Gy; P<.001) and the right cochlea (mean dose, 48.6 Gy vs 52.6 Gy; P=.02). The total planning time for RP-2 plans was significantly less than that for manual plans (64 minutes vs 295 minutes, P<.001). Conclusions: This study shows that RapidPlan can significantly improve planning efficiency and produce quality IMRT plans for NPC patients.

  1. Detection of an intense polychromatic gamma beam modulated at 3000 MHz; Detection d'un faisceau intense de gammas polychromatiques module a 3000 MHz

    Energy Technology Data Exchange (ETDEWEB)

    Beil, H; Veyssiere, A; Daujat, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    This paper presents two methods of detection of a {gamma} beam modulated at very high frequencies. The intense modulated beam is created by means of Bremsstrahlung in a gold-target, the latter having been placed in the emerging electron beam of the Linac at Saclay. A tentative interpretation of the physical phenomena involved in the detection processes is also given. The empirical data agree reasonably well with numerical evaluations based on well established theoretical concepts concerning these phenomena. (authors) [French] Cet article presente deux facons de detecter un faisceau de {gamma} module a haute frequence. Le faisceau intense de {gamma} est cree par l'impact d'electrons (acceleres dans un accelerateur lineaire) sur une cible en or. Une tentative d'interpretation des phenomenes physiques mis en cause dans le processus de detection est donnee et les valeurs experimentales trouvees s'accordent raisonnablement bien avec les valeurs calculees a partir des considerations theoriques des phenomenes. (auteurs)

  2. Parotid metastasis--an independent prognostic factor for head and neck cutaneous squamous cell carcinoma.

    Science.gov (United States)

    Ch'ng, S; Maitra, A; Lea, R; Brasch, H; Tan, S T

    2006-01-01

    Metastatic parotid cutaneous squamous cell carcinoma (SCC) is the most common parotid gland malignancy in New Zealand and Australia. The current AJCC TNM staging system does not account for the extent of nodal metastasis. A staging system that separates parotid (P stage) from neck disease (N stage) has been proposed recently. To review the outcome of patients with metastatic head and neck cutaneous SCC treated at our multidisciplinary Head and Neck Service using the proposed staging system. Consecutive patients were culled from our Head and Neck/Skull Base Database, 1990-2004. These patients were restaged according to the proposed staging system: P stage: P0 = no disease in the parotid (i.e., neck disease only); P1 = metastatic node P2=metastatic node > 3 cm and 6 cm, or disease involving the facial nerve or skull base. N stage: N0=no disease in the neck (i.e., parotid disease only); N1 = single ipsilateral metastatic node 3 cm, or contralateral neck involvement. Loco-regional recurrence and disease-specific survival were calculated using the Kaplan-Meier method and comparison of graphs made with the log-rank test. Multivariate analysis using the Cox regression model was carried out to assess the impact of various parameters. Sixty-seven patients with metastatic head and neck cutaneous SCC were identified. Thirty-seven patients had parotid metastasis (of whom 13 also had neck disease) while 21 had neck metastasis alone. Nine patients had dermal or soft tissue metastasis. These nine patients were excluded from this series, and data analysis was carried out on the remaining 58 (46 men, 12 women, mean age 71 years) patients. Sixty-seven percent of the patients underwent post-operative adjuvant radiotherapy. The five-year disease-specific survival rate was 54%. Among 56 patients followed up to disease recurrence or for a minimum period of 18 months, the loco-regional recurrence rate was 52%. The presence of parotid disease was an independent prognostic factor on

  3. Effects of methotrexate on rat parotid and submandibular glands and their secretions

    International Nuclear Information System (INIS)

    McBride, R.K.

    1986-01-01

    Experimental animals were injected intraperitoneally with methotrexate for 3 days. Parotid and submandibular main ducts were cannulated and saliva flow was evoked by either intravenous infusion of acetylcholine or an intravenous injection of benthanechol. Methotrexate was found to reduce significantly mean food consumption, body weight, and parotid gland wet weights. Experimental animal salivary total gland DNA levels were not different, but total parotid gland RNA, protein, amylase and water content, and submandibular gland RNA were significantly lower compared to control. Acetylcholine, but not bethanechol, evoked parotid protein and amylase outputs and submandibular protein output from experimental animals were significantly higher than the control groups'. The increased outputs were apparently linked to β-adrenergic receptor activation, since hexamethonium or propranolol eliminated the significant increases while phenoxybenzamine did not. Plasma catecholamine levels were significantly higher in the methotrexate treated animals and probably played a role in the salivary gland β-adrenergic activation. Methotrexate treatment significantly increased the submandibular gland β-adrenergic receptor concentration as determined by [ 3 H]-dihydroalprenolol receptor binding assays. Muscarinic receptor concentrations determined with [ 3 H]-quinuclidninyl benzilate were not changed

  4. Long-term Modulation of Cosmic Ray Intensity in relation to Sunspot ...

    Indian Academy of Sciences (India)

    it should be more closely connected with cosmic ray modulation than with other solar characteristics (sunspot numbers or coronal emission intensity). The intensity of galactic cosmic rays varies inversely with sunspot numbers, having their maximum intensity at the minimum of the 11-year sunspot cycle (Forbush 1954, 1958) ...

  5. Postoperative Intensity-Modulated Radiotherapy for Squamous Cell Carcinoma of the External Auditory Canal and Middle Ear: Treatment Outcomes, Marginal Misses, and Perspective on Target Delineation

    International Nuclear Information System (INIS)

    Chen, Wan-Yu; Kuo, Sung-Hsin; Chen, Yu-Hsuan; Lu, Szu-Huai; Tsai, Chiao-Ling; Chia-Hsien Cheng, Jason; Hong, Ruey-Long; Chen, Ya-Fang; Hsu, Chuan-Jen; Lin, Kai-Nan; Ko, Jenq-Yuh; Lou, Pei-Jen; Wang, Cheng-Ping; Chong, Fok-Ching; Wang, Chun-Wei

    2012-01-01

    Purpose: To report outcomes of the rare disease of squamous cell carcinoma (SCC) of the external auditory canal (EAC) and middle ear treated with surgery and postoperative intensity-modulated radiotherapy (IMRT). Failure patterns related to spatial dose distribution were also analyzed to provide insight into target delineation. Methods and Materials: A retrospective review was conducted of the records of 11 consecutive patients with SCC of the EAC and middle ear who were treated with curative surgery and postoperative IMRT at one institution between January 2007 and February 2010. The prescribed IMRT dose was 60 to 66 Gy at 2 Gy per fraction. Three patients also received concurrent cisplatin-based chemotherapy, and 1 patient received concurrent oral tegafur/uracil. The median follow-up time was 19 months (range, 6–33 months). Results: Four patients had locoregional recurrence, yielding an estimated 2-year locoregional control rate of 70.7%. Among them, 1 patient had persistent disease after treatment, and 3 had marginal recurrence. Distant metastasis occurred in 1 patient after extensive locoregional recurrence, yielding an estimated 2-year distant control rate of 85.7%. The estimated 2-year overall survival was 67.5%. The three cases of marginal recurrence were near the preauricular space and glenoid fossa of the temporomandibular joint, adjacent to the apex of the ear canal and glenoid fossa of the temporomandibular joint, and in the postauricular subcutaneous area and ipsilateral parotid nodes, respectively. Conclusions: Marginal misses should be recognized to improve target delineation. When treating SCC of the EAC and middle ear, care should be taken to cover the glenoid fossa of the temporomandibular joint and periauricular soft tissue. Elective ipsilateral parotid irradiation should be considered. The treatment planning procedure should also be refined to balance subcutaneous soft-tissue dosimetry and toxicity.

  6. Postoperative Intensity-Modulated Radiotherapy for Squamous Cell Carcinoma of the External Auditory Canal and Middle Ear: Treatment Outcomes, Marginal Misses, and Perspective on Target Delineation

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Wan-Yu [Division of Radiation Oncology, Department of Oncology, National Taiwan University Hospital, Taipei, Taiwan (China); Kuo, Sung-Hsin [Division of Radiation Oncology, Department of Oncology, National Taiwan University Hospital, Taipei, Taiwan (China); Graduate Institute of Clinical Medicine, National Taiwan University College of Medicine, Taipei, Taiwan (China); Chen, Yu-Hsuan; Lu, Szu-Huai; Tsai, Chiao-Ling [Division of Radiation Oncology, Department of Oncology, National Taiwan University Hospital, Taipei, Taiwan (China); Chia-Hsien Cheng, Jason [Division of Radiation Oncology, Department of Oncology, National Taiwan University Hospital, Taipei, Taiwan (China); Graduate Institute of Clinical Medicine, National Taiwan University College of Medicine, Taipei, Taiwan (China); Graduate Institute of Oncology, National Taiwan University College of Medicine, Taipei, Taiwan (China); Hong, Ruey-Long [Division of Medical Oncology, Department of Oncology, National Taiwan University Hospital, Taipei, Taiwan (China); Chen, Ya-Fang [Department of Medical Imaging, National Taiwan University Hospital, Taipei, Taiwan (China); Hsu, Chuan-Jen; Lin, Kai-Nan; Ko, Jenq-Yuh; Lou, Pei-Jen; Wang, Cheng-Ping [Department of Otolaryngology, National Taiwan University Hospital, Taipei, Taiwan (China); Chong, Fok-Ching [Graduate Institute of Electrical Engineering, National Taiwan University, Taipei, Taiwan (China); Wang, Chun-Wei, E-mail: cwwang@ntuh.gov.tw [Graduate Institute of Electrical Engineering, National Taiwan University, Taipei, Taiwan (China)

    2012-03-15

    Purpose: To report outcomes of the rare disease of squamous cell carcinoma (SCC) of the external auditory canal (EAC) and middle ear treated with surgery and postoperative intensity-modulated radiotherapy (IMRT). Failure patterns related to spatial dose distribution were also analyzed to provide insight into target delineation. Methods and Materials: A retrospective review was conducted of the records of 11 consecutive patients with SCC of the EAC and middle ear who were treated with curative surgery and postoperative IMRT at one institution between January 2007 and February 2010. The prescribed IMRT dose was 60 to 66 Gy at 2 Gy per fraction. Three patients also received concurrent cisplatin-based chemotherapy, and 1 patient received concurrent oral tegafur/uracil. The median follow-up time was 19 months (range, 6-33 months). Results: Four patients had locoregional recurrence, yielding an estimated 2-year locoregional control rate of 70.7%. Among them, 1 patient had persistent disease after treatment, and 3 had marginal recurrence. Distant metastasis occurred in 1 patient after extensive locoregional recurrence, yielding an estimated 2-year distant control rate of 85.7%. The estimated 2-year overall survival was 67.5%. The three cases of marginal recurrence were near the preauricular space and glenoid fossa of the temporomandibular joint, adjacent to the apex of the ear canal and glenoid fossa of the temporomandibular joint, and in the postauricular subcutaneous area and ipsilateral parotid nodes, respectively. Conclusions: Marginal misses should be recognized to improve target delineation. When treating SCC of the EAC and middle ear, care should be taken to cover the glenoid fossa of the temporomandibular joint and periauricular soft tissue. Elective ipsilateral parotid irradiation should be considered. The treatment planning procedure should also be refined to balance subcutaneous soft-tissue dosimetry and toxicity.

  7. Lymphoepithelial Carcinoma of Parotid Gland- A Case Report

    Directory of Open Access Journals (Sweden)

    Sachin A. Badge

    2014-07-01

    Full Text Available Lymphoepithelial carcinoma (LEC is most commonly seen in the nasopharynx. Very rarely it is found in the salivary gland, preferably in parotid gland followed by submandibular gland where it accounts for 0.4% of all malignant salivary gland tumours. Most commonly it is seen in fifth decade with female predominance. Significant correlation has been reported between this tumour and the Epstein Barr virus (EBV.It has a racial predilection for Inuits,Chinese and Japanese. Very rarely it is found In Indians. So we present a case of LEC of parotid gland in a 23 year old male Indian patient. As this is a very radiosensitive tumour, surgery followed by radiotherapy remains the treatment of choice.

  8. Critical spare parts ordering decisions using conditional reliability and stochastic lead time

    International Nuclear Information System (INIS)

    Godoy, David R.; Pascual, Rodrigo; Knights, Peter

    2013-01-01

    Asset-intensive companies face great pressure to reduce operation costs and increase utilization. This scenario often leads to over-stress on critical equipment and its spare parts associated, affecting availability, reliability, and system performance. As these resources impact considerably on financial and operational structures, the opportunity is given by demand for decision-making methods for the management of spare parts processes. We proposed an ordering decision-aid technique which uses a measurement of spare performance, based on the stress–strength interference theory; which we have called Condition-Based Service Level (CBSL). We focus on Condition Managed Critical Spares (CMS), namely, spares which are expensive, highly reliable, with higher lead times, and are not available in store. As a mitigation measure, CMS are under condition monitoring. The aim of the paper is orienting the decision time for CMS ordering or just continuing the operation. The paper presents a graphic technique which considers a rule for decision based on both condition-based reliability function and a stochastic/fixed lead time. For the stochastic lead time case, results show that technique is effective to determine the time when the system operation is reliable and can withstand the lead time variability, satisfying a desired service level. Additionally, for the constant lead time case, the technique helps to define insurance spares. In conclusion, presented ordering decision rule is useful to asset managers for enhancing the operational continuity affected by spare parts

  9. Carcinoma ex mixed tumor arising in the parotid gland

    International Nuclear Information System (INIS)

    Choi, Y. S.; Hwang, E. H.; Lee, S. R.

    2000-01-01

    Carcinoma ex mixed tumor is a mixed tumor in which a second neoplasm develops from the epithelial component that fulfills the criteria for malignancy. This tumor occurs frequently in the parotid glands. Individuals in whom carcinoma ex mixed tumor have a past history of benign mixed tumor. These lesions contain both a benign mixed tumor as well as a malignant neoplasm. We report a case of carcinoma ex mixed tumor which occurred in the parotid gland. A 67-year-old woman presented with movable right mass. She complained pain and facial paralysis. The clinical presentation, several diagnostic images, and histopathologic findings are presented.

  10. Comparison of Heart and Coronary Artery Doses Associated With Intensity-Modulated Radiotherapy Versus Three-Dimensional Conformal Radiotherapy for Distal Esophageal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kole, Thomas P.; Aghayere, Osarhieme; Kwah, Jason [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Yorke, Ellen D. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Goodman, Karyn A., E-mail: goodmank@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2012-08-01

    Purpose: To compare heart and coronary artery radiation exposure using intensity-modulated radiotherapy (IMRT) vs. four-field three-dimensional conformal radiotherapy (3D-CRT) treatment plans for patients with distal esophageal cancer undergoing chemoradiation. Methods and Materials: Nineteen patients with distal esophageal cancers treated with IMRT from March 2007 to May 2008 were identified. All patients were treated to 50.4 Gy with five-field IMRT plans. Theoretical 3D-CRT plans with four-field beam arrangements were generated. Dose-volume histograms of the planning target volume, heart, right coronary artery, left coronary artery, and other critical normal tissues were compared between the IMRT and 3D-CRT plans, and selected parameters were statistically evaluated using the Wilcoxon rank-sum test. Results: Intensity-modulated radiotherapy treatment planning showed significant reduction (p < 0.05) in heart dose over 3D-CRT as assessed by average mean dose (22.9 vs. 28.2 Gy) and V30 (24.8% vs. 61.0%). There was also significant sparing of the right coronary artery (average mean dose, 23.8 Gy vs. 35.5 Gy), whereas the left coronary artery showed no significant improvement (mean dose, 11.2 Gy vs. 9.2 Gy), p = 0.11. There was no significant difference in percentage of total lung volume receiving at least 10, 15, or 20 Gy or in the mean lung dose between the planning methods. There were also no significant differences observed for the kidneys, liver, stomach, or spinal cord. Intensity-modulated radiotherapy achieved a significant improvement in target conformity as measured by the conformality index (ratio of total volume receiving 95% of prescription dose to planning target volume receiving 95% of prescription dose), with the mean conformality index reduced from 1.56 to 1.30 using IMRT. Conclusions: Treatment of patients with distal esophageal cancer using IMRT significantly decreases the exposure of the heart and right coronary artery when compared with 3D

  11. Adjuvant whole abdominal intensity modulated radiotherapy (IMRT) for high risk stage FIGO III patients with ovarian cancer (OVAR-IMRT-01) – Pilot trial of a phase I/II study: study protocol

    International Nuclear Information System (INIS)

    Rochet, Nathalie; Jensen, Alexandra D; Sterzing, Florian; Munter, Marc W; Eichbaum, Michael H; Schneeweiss, Andreas; Sohn, Christof; Debus, Juergen; Harms, Wolfgang

    2007-01-01

    The prognosis for patients with advanced epithelial ovarian cancer remains poor despite aggressive surgical resection and platinum-based chemotherapy. More than 60% of patients will develop recurrent disease, principally intraperitoneal, and die within 5 years. The use of whole abdominal irradiation (WAI) as consolidation therapy would appear to be a logical strategy given its ability to sterilize small tumour volumes. Despite the clinically proven efficacy of whole abdominal irradiation, the use of radiotherapy in ovarian cancer has profoundly decreased mainly due to high treatment-related toxicity. Modern intensity-modulated radiation therapy (IMRT) could allow to spare kidneys, liver, and bone marrow while still adequately covering the peritoneal cavity with a homogenous dose. The OVAR-IMRT-01 study is a single center pilot trial of a phase I/II study. Patients with advanced ovarian cancer stage FIGO III (R1 or R2< 1 cm) after surgical resection and platinum-based chemotherapy will be treated with whole abdomen irradiation as consolidation therapy using intensity modulated radiation therapy (IMRT) to a total dose of 30 Gy in 1.5 Gy fractions. A total of 8 patients will be included in this trial. For treatment planning bone marrow, kidneys, liver, spinal cord, vertebral bodies and pelvic bones are defined as organs at risk. The planning target volume includes the entire peritoneal cavity plus pelvic and para-aortic node regions. The primary endpoint of the study is the evaluation of the feasibility of intensity-modulated WAI and the evaluation of the study protocol. Secondary endpoint is evaluation of the toxicity of intensity modulated WAI before continuing with the phase I/II study. The aim is to explore the potential of IMRT as a new method for WAI to decrease the dose to kidneys, liver, bone marrow while covering the peritoneal cavity with a homogenous dose, and to implement whole abdominal intensity-modulated radiotherapy into the adjuvant multimodal

  12. Evaluation of ultrasound in the diagnosis of parotid gland masses

    Directory of Open Access Journals (Sweden)

    Parotid gland

    1999-08-01

    Full Text Available In order to evaluate accuracy and usefulness of sonography and choose it as preliminary investigation method in pathologic processes of parotid gland, 50 patients were studied in duration of 16 months. The lesions were evaluated with ultrasound and sonographic images were obtained before surgery and then were compared with pathologic results after surgery. All lesions were detected with sonography. This method could differentiate intraglandular from extraglandular lesions with accuracy of 100%. Except one case of lipomatosis which was hyperechoic, all other lesions of parotid gland were hypoechoic. All lesions with sharp and well-defined borders were benign whereas malignant processes had ill-defined borders. The results obtained show that sonography is a reliable diagnostic method to differentiate benign from malignant lesions and it has a high diagnostic value to detect warthin's tumor, plemorphic adenoma, Sjogren's syndrome and lipomatosis. Presence of calcification in a parotid mass of young patient with high probabye is related to cavernous hemangioma.

  13. SU-E-T-302: Dosimetric Comparison Between Volumetric Modulated Arc Radiotherapy and Intensity-Modulated Radiotherapy for Locally Recurrent Nasopharyngeal Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lu, J-Y; Huang, B-T; Zhang, J-Y; Ma, C-C [Cancer Hospital of Shantou University Medical College, Shantou, Guangdong (China)

    2015-06-15

    Purpose: To compare volumetric modulated arc radiotherapy (VMAT) technique with fixed-gantry intensity-modulated radiotherapy (IMRT) technique for locally recurrent nasopharyngeal carcinoma. Methods: CT datasets of eleven nasopharyngeal-carcinoma patients were included. Dual-arc VMAT and seven-field IMRT plans were created for each case, and were then compared in terms of conformity index (CI), homogeneity index (HI) of the planning target volume (PTV), organ-at-risk (OAR) sparing, monitor unit (MU) and delivery time. Results: The D98% (near-minimal dose) of PTV in the VMAT plans was slightly lower than that of the IMRT plans (P < 0.05), while the CI was higher than that of the IMRT plans (P < 0.05). No significant difference was found in the HI between the two plans (P > 0.05). Compared with the IMRT plans, the VMAT plans demonstrated lower Dmean (mean dose) of the bilateral temporal lobes and the whole surrounding normal tissue (P < 0.05), but slightly higher Dmean of brainstem (P < 0.05). In terms of the other OARs, no significant differences were found (P > 0.05). The MUs of the VMAT plans (672 ± 112) was significantly lower than that of the IMRT plans (917 ± 206), by 25 ± 13% (P < 0.05). The average delivery time of the VMAT plans (2.3 ± 0.1 min) was less than that of the IMRT plans (5.1 ± 0.4 min), by 54 ± 3%. Conclusion: For locally recurrent nasopharyngeal carcinoma, the VMAT technique could achieve equivalent or superior dose distribution of the target and better protect the bilateral temporal lobes, compared with the IMRT technique. Moreover, it could reduce the MU and delivery time effectively.

  14. Accelerated Intensity-Modulated Radiotherapy to Breast in Prone Position: Dosimetric Results

    International Nuclear Information System (INIS)

    De Wyngaert, J. Keith; Jozsef, Gabor; Mitchell, James; Rosenstein, Barry; Formenti, Silvia C.

    2007-01-01

    Purpose: To report the physics and dosimetry results of a trial of accelerated intensity-modulated radiotherapy to the whole breast with a concomitant boost to the tumor bed in patients treated in the prone position. Methods and Materials: Patients underwent computed tomography planning and treatment in the prone position on a dedicated treatment platform. The platform has an open aperture on the side to allow for the index breast to fall away from the chest wall. Noncontrast computed tomography images were acquired at 2.5- or 3.75-mm-thick intervals, from the level of the mandible to below the diaphragm. A dose of 40.5 Gy was delivered to the entire breast at 2.7-Gy fractions in 15 fractions. An additional dose of 0.5 Gy was delivered as a concomitant boost to the lumpectomy site, with a 1-cm margin, using inverse planning, for a total dose of 48 Gy in 15 fractions. No more than 10% of the heart and lung volume was allowed to receive >18 and >20 Gy, respectively. Results: Between September 2003 and August 2005, 91 patients were enrolled in the study. The median volume of heart that received ≥18 Gy was 0.5%, with a maximal value of 4.7%. The median volume of ipsilateral lung that received ≥20 Gy was 0.8%, with a maximum of 7.2%. Conclusion: This technique for whole breast radiotherapy is feasible and enables an accelerated regimen in the prone position while sparing the lung and heart

  15. Structural differences between alcoholic and diabetic parotid sialosis.

    Science.gov (United States)

    Carda, Carmen; Carranza, Miriam; Arriaga, Adriana; Díaz, Anselmo; Peydró, Amando; Gomez de Ferraris, Maria Elsa

    2005-01-01

    Between the sialosis' etiologic agents, we can find the chronic alcoholism and diabetes. Both nosologic entities are described using a similar histopathologic pattern. The purpose of this work has been analyzing and comparing the histopathological differences between the diabetic and alcoholic sialosis. We studied 7 parotid glands samples of diabetic patients and 4 samples of normal glands obtained from surgical material were used as a control. For the comparative study, we used 12 parotid glands from chronic alcoholic patients with clinical diagnosis of cirrhosis and 6 autopsies on individuals who had died from alcoholic hepatic cirrhosis. This material was fixed in formaline, processed for embedding in paraffin, standard coloration techniques and immunotechnique for cytokeratin EA/1 y EA/3. In the cases of diabetics, the parotid gland was characterised by the presence of small acini, a bigger number of lipid intracytoplasmic droplets in the acinar and ductal cells, as well as an abundant adipose infiltration in the stroma when compared to the alcoholics. We observed that the cytokeratins' expression was heterogeneous at the acinar level, and very positive in the hyperplasic ducts, compared to the alcoholic and control groups. These qualitative valorations indicate the differences between the histopathologic pattern of sialosis with different origins.

  16. Treatment of locally advanced carcinomas of head and neck with intensity-modulated radiation therapy (IMRT) in combination with cetuximab and chemotherapy: the REACH protocol

    International Nuclear Information System (INIS)

    Habl, Gregor; Münter, Marc W; Jensen, Alexandra D; Potthoff, Karin; Uhl, Matthias; Hof, Holger; Hajda, Jacek; Simon, Christian; Debus, Jürgen; Krempien, Robert

    2010-01-01

    Primary treatment of carcinoma of the oro-/hypopharynx or larynx may consist of combined platinum-containing chemoradiotherapy. In order to improve clinical outcome (i.e. local control/overall survival), combined therapy is intensified by the addition of the EGFR inhibitor cetuximab (Erbitux ® ). Radiation therapy (RT) is carried out as intensity-modulated RT (IMRT) to avoid higher grade acute and late toxicity by sparing of surrounding normal tissues. The REACH study is a prospective phase II study combining chemoradiotherapy with carboplatin/5-Fluorouracil (5-FU) and the monoclonal epidermal growth factor-receptor (EGFR) antibody cetuximab (Erbitux ® ) as intensity-modulated radiation therapy in patients with locally advanced squamous-cell carcinomas of oropharynx, hypopharynx or larynx. Patients receive weekly chemotherapy infusions in the 1 st and 5 th week of RT. Additionally, cetuximab is administered weekly throughout the treatment course. IMRT is delivered as in a classical concomitant boost concept (bid from fraction 16) to a total dose of 69,9 Gy. Primary endpoint of the trial is local-regional control (LRC). Disease-free survival, progression-free survival, overall survival, toxicity, proteomic and genomic analyses are secondary endpoints. The aim is to explore the efficacy as well as the safety and feasibility of this combined radioimmunchemotherapy in order to improve the outcome of patients with advanced head and neck cancer. ISRCTN87356938

  17. Treatment of locally advanced carcinomas of head and neck with intensity-modulated radiation therapy (IMRT in combination with cetuximab and chemotherapy: the REACH protocol

    Directory of Open Access Journals (Sweden)

    Simon Christian

    2010-11-01

    Full Text Available Abstract Background Primary treatment of carcinoma of the oro-/hypopharynx or larynx may consist of combined platinum-containing chemoradiotherapy. In order to improve clinical outcome (i.e. local control/overall survival, combined therapy is intensified by the addition of the EGFR inhibitor cetuximab (Erbitux®. Radiation therapy (RT is carried out as intensity-modulated RT (IMRT to avoid higher grade acute and late toxicity by sparing of surrounding normal tissues. Methods/Design The REACH study is a prospective phase II study combining chemoradiotherapy with carboplatin/5-Fluorouracil (5-FU and the monoclonal epidermal growth factor-receptor (EGFR antibody cetuximab (Erbitux® as intensity-modulated radiation therapy in patients with locally advanced squamous-cell carcinomas of oropharynx, hypopharynx or larynx. Patients receive weekly chemotherapy infusions in the 1st and 5th week of RT. Additionally, cetuximab is administered weekly throughout the treatment course. IMRT is delivered as in a classical concomitant boost concept (bid from fraction 16 to a total dose of 69,9 Gy. Discussion Primary endpoint of the trial is local-regional control (LRC. Disease-free survival, progression-free survival, overall survival, toxicity, proteomic and genomic analyses are secondary endpoints. The aim is to explore the efficacy as well as the safety and feasibility of this combined radioimmunchemotherapy in order to improve the outcome of patients with advanced head and neck cancer. Trial registration ISRCTN87356938

  18. [Acute neonatal suppurative parotiditis: about three clinical cases and review of the literature].

    Science.gov (United States)

    Isfaoun, Zineb; Radouani, Mohammed Amine; Azzaoui, Sihame; Knouni, Houria; Aguenaou, Hassan; Barkat, Amina

    2016-01-01

    The following case study reports three cases of neonatal bacterial parotiditis observed over a period of seven months. Diagnosis is often based on patient's clinical features: they typically include hyperthermia, swelling, erythema, warmth as well as local tenderness and purulent discharge at Stensen duct during the massage of the parotid. The clinical diagnosis is confirmed by ultrasound and by culture of parotid purulent secretion. They are mainly of nosocomial origin and are generally caused by prematurity and dehydration. Early treatment improves patient outcome. Risk factors such as age should lead clinicians to start empiric antibiotic therapy first and then antibiotic therapy based on direct examination of pus extracted from Stensen duct. Staphylococcus aureus, Streptococcus Viridans and anaerobic germs are most commonly isolated. Acute parotiditis are extremely rare in the neonatal period: less than 50 cases have been reported in the literature. We here report three rather peculiar cases. The diagnosis was suspected on the basis of signs of local inflammation.

  19. Early changes of parotid density and volume predict modifications at the end of therapy and intensity of acute xerostomia

    International Nuclear Information System (INIS)

    Belli, Maria Luisa; Broggi, Sara; Scalco, Elisa; Rizzo, Giovanna; Sanguineti, Giuseppe; Fiorino, Claudio; Cattaneo, Giovanni Mauro; Dinapoli, Nicola; Valentini, Vincenzo; Ricchetti, Francesco

    2014-01-01

    To quantitatively assess the predictive power of early variations of parotid gland volume and density on final changes at the end of therapy and, possibly, on acute xerostomia during IMRT for head-neck cancer. Data of 92 parotids (46 patients) were available. Kinetics of the changes during treatment were described by the daily rate of density (rΔρ) and volume (rΔvol) variation based on weekly diagnostic kVCT images. Correlation between early and final changes was investigated as well as the correlation with prospective toxicity data (CTCAEv3.0) collected weekly during treatment for 24/46 patients. A higher rΔρ was observed during the first compared to last week of treatment (-0,50 vs -0,05HU, p-value = 0.0001). Based on early variations, a good estimation of the final changes may be obtained (Δρ: AUC = 0.82, p = 0.0001; Δvol: AUC = 0.77, p = 0.0001). Both early rΔρ and rΔvol predict a higher ''mean'' acute xerostomia score (≥ median value, 1.57; p-value = 0.01). Median early density rate changes for patients with mean xerostomia score ≥ / 3 /day for rΔρ and rΔvol respectively. Further studies are necessary to definitively assess the potential of early density/volume changes in identifying more sensitive patients at higher risk of experiencing xerostomia. (orig.) [de

  20. Energy and intensity modulated radiation therapy with electrons

    OpenAIRE

    Olofsson, Lennart

    2005-01-01

    In recent years intensity modulated radiation therapy with photons (xIMRT) has gained attention due to its ability to reduce the dose in the tissues close to the tumour volume. However, this technique also results in a large low dose volume. Electron IMRT (eIMRT) has the potential to reduce the integral dose to the patient due to the dose fall off in the electron depth dose curves. This dose fall off makes it possible to modulate the dose distribution in the direction of the beam by selecting...

  1. Light induced modulation instability of surfaces under intense illumination

    KAUST Repository

    Burlakov, V. M.

    2013-12-17

    We show that a flat surface of a polymer in rubber state illuminated with intense electromagnetic radiation is unstable with respect to periodic modulation. Initial periodic perturbation is amplified due to periodic thermal expansion of the material heated by radiation. Periodic heating is due to focusing-defocusing effects caused by the initial surface modulation. The surface modulation has a period longer than the excitation wavelength and does not require coherent light source. Therefore, it is not related to the well-known laser induced periodic structures on polymer surfaces but may contribute to their formation and to other phenomena of light-matter interaction.

  2. Conformal radiotherapy by intensity modulation of pediatrics tumors

    International Nuclear Information System (INIS)

    Leseur, J.; Le Prise, E.; Carrie, C.; Bernier, V.; Beneyton, V.; Mahe, M.A.; Supiot, S.

    2009-01-01

    The objective of this study is to take stock on the validated and potential indications of the conformal radiotherapy with intensity modulation ( intensity modulated radiotherapy I.M.R.T.) in pediatrics and to propose recommendations for its use as well as the adapted dose constraints. About 40 to 50% of children treated for a cancer are irradiated. The I.M.R.T., by linear accelerator or helical tomo-therapy has for aim to give a homogenous dose to the target volume and to save organs at risk. Its use in pediatrics seems particularly interesting because of the complexity of target volumes and the closeness of organs at risk. In compensation for these positive elements, the importance of low doses irradiation given in big volumes makes fear event consequences on growth and an increased incidence of secondary cancers in children suffering from tumors with high cure rates and long life expectancy. (N.C.)

  3. High-Dose and Extended-Field Intensity Modulated Radiation Therapy for Early-Stage NK/T-Cell Lymphoma of Waldeyer's Ring: Dosimetric Analysis and Clinical Outcome

    Energy Technology Data Exchange (ETDEWEB)

    Bi, Xi-Wen; Li, Ye-Xiong, E-mail: yexiong@yahoo.com; Fang, Hui; Jin, Jing; Wang, Wei-Hu; Wang, Shu-Lian; Liu, Yue-Ping; Song, Yong-Wen; Ren, Hua; Dai, Jian-Rong

    2013-12-01

    Purpose: To assess the dosimetric benefit, treatment outcome, and toxicity of high-dose and extended-field intensity modulated radiation therapy (IMRT) in patients with early-stage NK/T-cell lymphoma of Waldeyer's ring (WR-NKTCL). Methods and Materials: Thirty patients with early-stage WR-NKTCL who received extended-field IMRT were retrospectively reviewed. The prescribed dose was 50 Gy to the primary involved regions and positive cervical lymph nodes (planning target volume requiring radical irradiation [PTV{sub 50}]) and 40 Gy to the negative cervical nodes (PTV{sub 40}). Dosimetric parameters for the target volume and critical normal structures were evaluated. Locoregional control (LRC), overall survival (OS), and progression-free survival (PFS) were calculated using the Kaplan-Meier method. Results: The median mean doses to the PTV{sub 50} and PTV{sub 40} were 53.2 Gy and 43.0 Gy, respectively. Only 1.4% of the PTV{sub 50} and 0.9% of the PTV{sub 40} received less than 95% of the prescribed dose, indicating excellent target coverage. The average mean doses to the left and right parotid glands were 27.7 and 28.4 Gy, respectively. The 2-year OS, PFS, and LRC rates were 71.2%, 57.4%, and 87.8%. Most acute toxicities were grade 1 to 2, except for grade ≥3 dysphagia and mucositis. The most common late toxicity was grade 1-2 xerostomia, and no patient developed any ≥grade 3 late toxicities. A correlation between the mean dose to the parotid glands and the degree of late xerostomia was observed. Conclusions: IMRT achieves excellent target coverage and dose conformity, as well as favorable survival and locoregional control rates with acceptable toxicities in patients with WR-NKTCL.

  4. Effects of methotrexate on rat parotid and submandibular glands and their secretions

    Energy Technology Data Exchange (ETDEWEB)

    McBride, R.K.

    1986-01-01

    Experimental animals were injected intraperitoneally with methotrexate for 3 days. Parotid and submandibular main ducts were cannulated and saliva flow was evoked by either intravenous infusion of acetylcholine or an intravenous injection of benthanechol. Methotrexate was found to reduce significantly mean food consumption, body weight, and parotid gland wet weights. Experimental animal salivary total gland DNA levels were not different, but total parotid gland RNA, protein, amylase and water content, and submandibular gland RNA were significantly lower compared to control. Acetylcholine, but not bethanechol, evoked parotid protein and amylase outputs and submandibular protein output from experimental animals were significantly higher than the control groups'. The increased outputs were apparently linked to ..beta..-adrenergic receptor activation, since hexamethonium or propranolol eliminated the significant increases while phenoxybenzamine did not. Plasma catecholamine levels were significantly higher in the methotrexate treated animals and probably played a role in the salivary gland ..beta..-adrenergic activation. Methotrexate treatment significantly increased the submandibular gland ..beta..-adrenergic receptor concentration as determined by (/sup 3/H)-dihydroalprenolol receptor binding assays. Muscarinic receptor concentrations determined with (/sup 3/H)-quinuclidninyl benzilate were not changed.

  5. Intensity position modulation for free-space laser communication system

    Science.gov (United States)

    Jangjoo, Alireza; Faghihi, F.

    2004-12-01

    In this research a novel modulation technique for free-space laser communication system called Intensity Position Modulation (IPM) is carried out. According to TEM00 mode of a laser beam and by linear fitting on the Gaussian function as an approximation, the variation of linear part on the reverse biased pn photodiode produced alternating currents which contain the information. Here, no characteristic property of the beam as intensity or frequency is changed and only the beam position moves laterally. We demonstrated that in this method no bandwidth is required, so it is possible to reduce the background radiation noise by narrowband filtering of the carrier. The fidelity of the analog voice communication system which is made upon the IPM is satisfactory and we are able to transmit the audio signals up to 1Km.

  6. Land Sparing and Land Sharing Policies in Developing Countries - Drivers and Linkages to Scientific Debates

    DEFF Research Database (Denmark)

    Mertz, Ole; Mertens, Charlotte Filt

    2017-01-01

    The need for developing land sparing or land sharing policies for protecting the environment has been a polarized debate in the scientific literature. Some studies show that "spared" landscapes with clearly separated intensive agriculture and pristine forest are better for biodiversity and other...... ecosystem services, whereas others demonstrate the benefits of "shared" mosaic landscapes composed of a mix of forest types, agricultural fields, grassland, and plantations. Increasingly, these scientific views have been depolarized, recognizing that both shared and spared landscapes have a role to play......, depending on the context. However, it is less clear from the literature what drives actual policy-making related to land sparing and land sharing in developing countries and what the outcomes of these policies are. We therefore reviewed the international peer-reviewed literature for evidence of policies...

  7. Measuring high-frequency responses of an electro-optic phase modulator based on dispersion induced phase modulation to intensity modulation conversion

    Science.gov (United States)

    Zhang, Shangjian; Wang, Heng; Wang, Yani; Zou, Xinhai; Zhang, Yali; Liu, Shuang; Liu, Yong

    2014-11-01

    We investigate the phase modulation to intensity modulation conversion in dispersive fibers for measuring frequency responses of electro-optic phase modulators, and demonstrate two typical measurements with cascade path and fold-back path. The measured results achieve an uncertainty of less than 2.8% within 20 GHz. Our measurements show stable and repeatable results because the optical carrier and its phase-modulated sidebands are affected by the same fiber impairments. The proposed method requires only dispersive fibers and works without any small-signal assumption, which is applicable for swept frequency measurement at different driving levels and operating wavelengths.

  8. Random and systematic beam modulator errors in dynamic intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Parsai, Homayon; Cho, Paul S; Phillips, Mark H; Giansiracusa, Robert S; Axen, David

    2003-01-01

    This paper reports on the dosimetric effects of random and systematic modulator errors in delivery of dynamic intensity modulated beams. A sliding-widow type delivery that utilizes a combination of multileaf collimators (MLCs) and backup diaphragms was examined. Gaussian functions with standard deviations ranging from 0.5 to 1.5 mm were used to simulate random positioning errors. A clinical example involving a clival meningioma was chosen with optic chiasm and brain stem as limiting critical structures in the vicinity of the tumour. Dose calculations for different modulator fluctuations were performed, and a quantitative analysis was carried out based on cumulative and differential dose volume histograms for the gross target volume and surrounding critical structures. The study indicated that random modulator errors have a strong tendency to reduce minimum target dose and homogeneity. Furthermore, it was shown that random perturbation of both MLCs and backup diaphragms in the order of σ = 1 mm can lead to 5% errors in prescribed dose. In comparison, when MLCs or backup diaphragms alone was perturbed, the system was more robust and modulator errors of at least σ = 1.5 mm were required to cause dose discrepancies greater than 5%. For systematic perturbation, even errors in the order of ±0.5 mm were shown to result in significant dosimetric deviations

  9. Dosimetric comparison between helical tomotherapy and volumetric modulated arc-therapy for non-anaplastic thyroid cancer treatment.

    Science.gov (United States)

    Khalifa, Jonathan; Vieillevigne, Laure; Boyrie, Sabrina; Ouali, Monia; Filleron, Thomas; Rives, Michel; Laprie, Anne

    2014-11-26

    To evaluate and compare dosimetric parameters of volumetric modulated arctherapy (VMAT) and helical tomotherapy (HT) for non-anaplastic thyroid cancer adjuvant radiotherapy. Twelve patients with non-anaplastic thyroid cancer at high risk of local relapse received adjuvant external beam radiotherapy with curative intent in our institution, using a two-dose level prescription with a simultaneous integrated boost approach. Each patient was re-planned by the same physicist twice using both VMAT and HT. Several dosimetric quality indexes were used: target coverage index (proportion of the target volume covered by the reference isodose), healthy tissue conformity index (proportion of the reference isodose volume including the target volume), conformation number (combining both previous indexes), Dice Similarity Coefficient (DSC), and homogeneity index ((D2%-D98%)/prescribed dose). Dose-volume histogram statistics were also compared. HT provided statistically better target coverage index and homogeneity index for low risk PTV in comparison with VMAT (respectively 0.99 vs. 0.97 (p=0.008) and 0.22 vs. 0.25 (p=0.016)). However, HT provided poorer results for healthy tissue conformity index, conformation number and DSC with low risk and high risk PTV. As regards organs at risk sparing, by comparison with VMAT, HT statistically decreased the D2% to medullary canal (25.3 Gy vs. 32.6 Gy (p=0.003)). Besides, HT allowed a slight sparing dose for the controlateral parotid (Dmean: 4.3 Gy vs. 6.6 Gy (p=0.032)) and for the controlateral sub-maxillary gland (Dmean: 29.1 Gy vs. 33.1 Gy (p=0.041)). Both VMAT and HT techniques for adjuvant treatment of non-anaplastic thyroid cancer provide globally attractive treatment plans with slight dosimetric differences. However, helical tomotherapy clearly provides a benefit in term of medullary canal sparing.

  10. Primary hydatid disease of the infratemporal fossa and the parotid gland

    International Nuclear Information System (INIS)

    Kalovidouris, A.; Gouliamos, A.; Andreou, I.; Levett, J.; Vlahos, I.; Papavasiliou, C.; Ioannovits, I.

    1985-01-01

    Hydatid disease should be considered in the differential diagnosis of lesions causing swelling of the parotid area or exophthalmos in patients originating from countries where the incidence of the disease is high. An unusual case of hydatid disease located in the infratemporal fossa and the anterior parotid region is presented. Computed Tomography is a valuable tool for establishment of the diagnosis, before any surgical approach to the lesion is initiated and for postoperative follow-up and evaluation. (orig.) [de

  11. Primary hydatid disease of the infratemporal fossa and the parotid gland

    Energy Technology Data Exchange (ETDEWEB)

    Kalovidouris, A.; Gouliamos, A.; Andreou, I.; Levett, J.; Vlahos, I.; Papavasiliou, C.; Ioannovits, I.

    1985-05-01

    Hydatid disease should be considered in the differential diagnosis of lesions causing swelling of the parotid area or exophthalmos in patients originating from countries where the incidence of the disease is high. An unusual case of hydatid disease located in the infratemporal fossa and the anterior parotid region is presented. Computed Tomography is a valuable tool for establishment of the diagnosis, before any surgical approach to the lesion is initiated and for postoperative follow-up and evaluation.

  12. The QUANTEC criteria for parotid gland dose and their efficacy to prevent moderate to severe patient-rated xerostomia.

    Science.gov (United States)

    Beetz, Ivo; Steenbakkers, Roel J H M; Chouvalova, Olga; Leemans, Charles R; Doornaert, Patricia; van der Laan, Bernard F A M; Christianen, Miranda E M C; Vissink, Arjan; Bijl, Henk P; van Luijk, Peter; Langendijk, Johannes A

    2014-05-01

    Recently, the Quantitative Analysis of Normal Tissue Effect in the Clinic (QUANTEC) Group defined dose-volume constraints for the parotid glands to avoid severe xerostomia. The aim of this study was to determine if application of these QUANTEC criteria also protected against moderate-to-severe patient-rated xerostomia. The study population consisted of 307 head and neck cancer patients treated with primary (chemo)radiotherapy, either with 3D-CRT (56%) or with IMRT (44%). All patients participated in a standard follow-up program in which radiation-induced toxicity and quality of life were prospectively assessed. Patients who met the QUANTEC criteria were classified as low risk and otherwise as high risk. In total, 41% of the patients (treated with 3D-CRT and IMRT) were classified as low risk patients. In the group treated with 3D-CRT and IMRT, it was possible to meet the QUANTEC criteria in 47% and 32% of the patients, respectively. Sparing the parotid glands with IMRT was considerably more difficult in patients with lymph node metastases and in patients with nasopharyngeal and oropharyngeal tumours. Low risk patients reported significantly less moderate-to-severe xerostomia than high risk patients. However, the predicted risk of elderly patients and patients with pre-existing minor patient-rated xerostomia at baseline was > 20%, even when the QUANTEC criteria were met. Significantly lower rates of radiation-induced patient-rated xerostomia were found among low risk patients treated according to the QUANTEC criteria, but these criteria do not completely protect against xerostomia. Particularly in elderly patients and patients already suffering from minor xerostomia at baseline, the QUANTEC criteria do not sufficiently protect against persistent, moderate-to-severe patient-rated xerostomia.

  13. Cell phone use is associated with an inflammatory cytokine profile of parotid gland saliva.

    Science.gov (United States)

    Siqueira, Elisa Carvalho; de Souza, Fabrício Tinôco Alvim; Ferreira, Efigênia; Souza, Renan Pedra; Macedo, Samuel Costa; Friedman, Eitan; Gomez, Marcus Vinícius; Gomes, Carolina Cavaliéri; Gomez, Ricardo Santiago

    2016-10-01

    There is controversy on the effects of the non-ionizing radiation emitted by cell phones on cellular processes and the impact of such radiation exposure on health. The purpose of this study was to investigate whether cell phone use alters cytokine expression in the saliva produced by the parotid glands. Cytokine expression profile was determined by enzyme linked immuno sorbent assay (ELISA) in the saliva produced by the parotid glands in healthy volunteers, and correlated with self-reported cell phone use and laterality. The following parameters were determined, in 83 Brazilian individuals in saliva produced by the parotid glands comparing the saliva from the gland exposed to cell phone radiation (ipsilateral) to that from the contralateral parotid: salivary flow, total protein concentration, interleukin 1 β (IL-1 β), interleukin 6 (IL-6), interleukin 10 (IL-10), interferon γ (IFN-γ), and tumor necrosis factor α (TNF-α) salivary levels by ELISA. After multiple testing correction, decreased IL-10 and increased IL-1β salivary levels in the ipsilateral side compared with the contralateral side (P cell phones for more than 10 years presented higher differences between IL-10 levels in ipsilateral versus contralateral parotids (P = 0.0012). No difference was observed in any of the tested parameters in correlation with cell phone monthly usage in minutes. The exposure of parotid glands to cell phones can alter salivary IL-10 and IL-1β levels, consistent with a pro-inflammatory microenvironment that may be related to heat production. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Subcarrier intensity modulation for MIMO visible light communications

    Science.gov (United States)

    Celik, Yasin; Akan, Aydin

    2018-04-01

    In this paper, subcarrier intensity modulation (SIM) is investigated for multiple-input multiple-output (MIMO) visible light communication (VLC) systems. A new modulation scheme called DC-aid SIM (DCA-SIM) is proposed for the spatial modulation (SM) transmission plan. Then, DCA-SIM is extended for multiple subcarrier case which is called DC-aid Multiple Subcarrier Modulation (DCA-MSM). Bit error rate (BER) performances of the considered system are analyzed for different MIMO schemes. The power efficiencies of DCA-SIM and DCA-MSM are shown in correlated MIMO VLC channels. The upper bound BER performances of the proposed models are obtained analytically for PSK and QAM modulation types in order to validate the simulation results. Additionally, the effect of power imbalance method on the performance of SIM is studied and remarkable power gains are obtained compared to the non-power imbalanced cases. In this work, Pulse amplitude modulation (PAM) and MSM-Index are used as benchmarks for single carrier and multiple carrier cases, respectively. And the results show that the proposed schemes outperform PAM and MSM-Index for considered single carrier and multiple carrier communication scenarios.

  15. Quantitative dose-volume response analysis of changes in parotid gland function after radiotherapy in the head-and-neck region

    International Nuclear Information System (INIS)

    Roesink, Judith M.; Moerland, Marinus A.; Battermann, Jan J.; Hordijk, Gerrit Jan; Terhaard, Chris H.J.

    2001-01-01

    Purpose: To study the radiation tolerance of the parotid glands as a function of dose and volume irradiated. Methods and Materials: One hundred eight patients treated with primary or postoperative radiotherapy for various malignancies in the head-and-neck region were prospectively evaluated. Stimulated parotid flow rate was measured before radiotherapy and 6 weeks, 6 months, and 1 year after radiotherapy. Parotid gland dose-volume histograms were derived from CT-based treatment planning. The normal tissue complication probability model proposed by Lyman was fit to the data. A complication was defined as stimulated parotid flow rate 50 (the dose to the whole organ leading to a complication probability of 50%) was found to be 31, 35, and 39 Gy at 6 weeks, 6 months, and 1 year postradiotherapy, respectively. The volume dependency parameter n was around 1, which means that the mean parotid dose correlates best with the observed complications. There was no steep dose-response curve (m=0.45 at 1 year postradiotherapy). Conclusions: This study on dose/volume/parotid gland function relationships revealed a linear correlation between postradiotherapy flow ratio and parotid gland dose and a strong volume dependency. No threshold dose was found. Recovery of parotid gland function was shown at 6 months and 1 year after radiotherapy. In radiation planning, attempts should be made to achieve a mean parotid gland dose at least below 39 Gy (leading to a complication probability of 50%)

  16. A Nomogram to predict parotid gland overdose in head and neck IMRT

    International Nuclear Information System (INIS)

    Castelli, J.; Simon, A.; Rigaud, B.; Lafond, C.; Chajon, E.; Ospina, J. D.; Haigron, P.; Laguerre, B.; Loubière, A. Ruffier; Benezery, K.; Crevoisier, R. de

    2016-01-01

    To generate a nomogram to predict parotid gland (PG) overdose and to quantify the dosimetric benefit of weekly replanning based on its findings, in the context of intensity-modulated radiotherapy (IMRT) for locally-advanced head and neck carcinoma (LAHNC). Twenty LAHNC patients treated with radical IMRT underwent weekly computed tomography (CT) scans during IMRT. The cumulated PG dose was estimated by elastic registration. Early predictors of PG overdose (cumulated minus planned doses) were identified, enabling a nomogram to be generated from a linear regression model. Its performance was evaluated using a leave-one-out method. The benefit of weekly replanning was then estimated for the nomogram-identified PG overdose patients. Clinical target volume 70 (CTV70) and the mean PG dose calculated from the planning and first weekly CTs were early predictors of PG overdose, enabling a nomogram to be generated. A mean PG overdose of 2.5Gy was calculated for 16 patients, 14 identified by the nomogram. All patients with PG overdoses >1.5Gy were identified. Compared to the cumulated delivered dose, weekly replanning of these 14 targeted patients enabled a 3.3Gy decrease in the mean PG dose. Based on the planning and first week CTs, our nomogram allowed the identification of all patients with PG overdoses >2.5Gy to be identified, who then benefitted from a final 4Gy decrease in mean PG overdose by means of weekly replanning

  17. Intensity-Modulated Radiotherapy versus 3-Dimensional Conformal Radiotherapy Strategies for Locally Advanced Non-Small-Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Uğur Selek

    2014-12-01

    Full Text Available Chemoradiotherapy is the current standard of care in patients with advanced inoperable stage IIIA or IIIB non-small cell lung cancer (NSCLC. Three-dimensional radiotherapy (3DCRT has been a trusted method for a long time and has well-known drawbacks, most of which could be improved by Intensity Modulated Radiotherapy (IMRT. IMRT is not currently the standard treatment of locally advanced NSCLC, but almost all patients could benefit to a degree in organ at risk sparing, dose coverage conformality, or dose escalation. The most critical step for a radiation oncology department is to strictly evaluate its own technical and physical capabilities to determine the ability of IMRT to deliver an optimal treatment plan. This includes calculating the internal tumor motion (ideally 4DCT or equivalent techniques, treatment planning software with an up-to-date heterogeneity correction algorithm, and daily image guidance. It is crucial to optimise and individualise the therapeutic ratio for each patient during the decision of 3DCRT versus IMRT. The current literature rationalises the increasing use of IMRT, including 4D imaging plus PET/CT, and encourages the applicable knowledge-based and individualised dose escalation using advanced daily image-guided radiotherapy.

  18. Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment

    Directory of Open Access Journals (Sweden)

    Bora Uysal

    2013-03-01

    Full Text Available Objective: The purpose of this dosimetric study is the targeted dose homogeneity and critical organ dose comparison of 7-field Intensity Modulated Radiotherapy (IMRT and 3-D 4-field conformal radiotherapy. Study Design: Cross sectional study. Material and Methods: Twenty patients with low and moderate risk prostate cancer treated at Gülhane Military Medical School Radiation Oncology Department between January 2009 and December 2009 are included in this study. Two seperate dosimetric plans both for 7-field IMRT and 3D-CRT have been generated for each patient to comparatively evaluate the dosimetric status of both techniques and all the patients received 7-field IMRT. Results: Dose-comparative evaluation of two techniques revealed the superiority of IMRT technique with statistically significantly lower femoral head doses along with reduced critical organ dose-volume parameters of bladder V60 (the volume receiving 60 Gy and rectal V40 (the volume receiving 40 Gy and V60. Conclusion: It can be concluded that IMRT is an effective definitive management tool for prostate cancer with improved critical organ sparing and excellent dose homogenization in target organs of prostate and seminal vesicles.

  19. Paraganglioma with unusual presentation in parotid gland: A diagnostic dilemma in fine needle aspiration

    Directory of Open Access Journals (Sweden)

    Anagh A Vora

    2012-01-01

    Full Text Available Paragangliomas (PGLs are uncommon tumors. Although PGLs are known to occur in the head and neck region, especially the carotid body, middle ear, and larynx, involvement of the parotid glands has not been reported. In this article, we report the fine needle aspiration features of tumor in an unusual location, presenting as a parotid gland mass, submitted to pathology for initial diagnosis. The clinical presentation, cytomorphology, and the immunohistochemical features for the diagnosis are described. To our knowledge, this is the first case of paraganglioma of the parotid gland reported in the literature.

  20. Assessment of improved organ at risk sparing for advanced cervix carcinoma utilizing precision radiotherapy techniques

    Energy Technology Data Exchange (ETDEWEB)

    Georg, D.; Georg, P.; Hillbrand, M.; Poetter, R.; Mock, U. [Dept. of Radiotherapy, Medical Univ. AKH, Vienna (Austria)

    2008-11-15

    Purpose: to evaluate the potential benefit of proton therapy and photon based intensity-modulated radiotherapy in comparison to 3-D conformal photon radiotherapy (3D-CRT) in locally advanced cervix cancer. Patients and methods: in five patients with advanced cervix cancer 3D-CRT (four-field box) was compared with intensity modulated photon (IMXT) and proton therapy (IMPT) as well as proton beam therapy (PT) based on passive scattering. Planning target volumes (PTVs) included primary tumor and pelvic and para-aortic lymph nodes. Dose-volume histograms (DVHs) were analyzed for the PTV and various organs at risk (OARs) (rectal wall, bladder, small bowel, colon, femoral heads, and kidneys). In addition dose conformity, dose inhomogeneity and overall volumes of 50% isodoses were assessed. Results: all plans were comparable concerning PTV parameters. Large differences between photon and proton techniques were seen in volumes of the 50% isodoses and conformity indices. DVH for colon and small bowel were significantly improved with PT and IMPT compared to IMXT, with D{sub mean} reductions of 50-80%. Doses to kidneys and femoral heads could also be substantially reduced with PT and IMPT. Sparing of rectum and bladder was superior with protons as well but less pronounced. Conclusion: proton beam RT has significant potential to improve treatment related side effects in the bowel compared to photon beam RT in patients with advanced cervix carcinoma. (orig.)

  1. Assessment of improved organ at risk sparing for advanced cervix carcinoma utilizing precision radiotherapy techniques

    International Nuclear Information System (INIS)

    Georg, D.; Georg, P.; Hillbrand, M.; Poetter, R.; Mock, U.

    2008-01-01

    Purpose: to evaluate the potential benefit of proton therapy and photon based intensity-modulated radiotherapy in comparison to 3-D conformal photon radiotherapy (3D-CRT) in locally advanced cervix cancer. Patients and methods: in five patients with advanced cervix cancer 3D-CRT (four-field box) was compared with intensity modulated photon (IMXT) and proton therapy (IMPT) as well as proton beam therapy (PT) based on passive scattering. Planning target volumes (PTVs) included primary tumor and pelvic and para-aortic lymph nodes. Dose-volume histograms (DVHs) were analyzed for the PTV and various organs at risk (OARs) (rectal wall, bladder, small bowel, colon, femoral heads, and kidneys). In addition dose conformity, dose inhomogeneity and overall volumes of 50% isodoses were assessed. Results: all plans were comparable concerning PTV parameters. Large differences between photon and proton techniques were seen in volumes of the 50% isodoses and conformity indices. DVH for colon and small bowel were significantly improved with PT and IMPT compared to IMXT, with D mean reductions of 50-80%. Doses to kidneys and femoral heads could also be substantially reduced with PT and IMPT. Sparing of rectum and bladder was superior with protons as well but less pronounced. Conclusion: proton beam RT has significant potential to improve treatment related side effects in the bowel compared to photon beam RT in patients with advanced cervix carcinoma. (orig.)

  2. A comparison of morbidity following conformal versus intensity-modulated radiotherapy for urinary bladder cancer.

    Science.gov (United States)

    Søndergaard, Jimmi; Holmberg, Mats; Jakobsen, Annette Ross; Agerbæk, Mads; Muren, Ludvig Paul; Høyer, Morten

    2014-10-01

    In radiotherapy (RT) of urinary bladder cancer, the use of intensity-modulated RT (IMRT) opens for sparing of considerable intestinal volumes. The purpose of the present study was to investigate the acute and late toxicities following either conformal RT (CRT) or IMRT for bladder cancer, and to correlate the toxicities to dose-volume parameters. The study included 116 consecutively treated patients with muscle-invasive bladder cancer who received either CRT (n = 66) or IMRT (n = 50) during 2007-2010. Acute side effects were retrospectively collected whereas late effects were assessed by a cross-sectional evaluation by telephone interview of 44 recurrence-free patients. Acute and late toxicities were scored according to the Common Terminology Criteria for Adverse Event (CTCAE) version 3.0. Acute diarrhoea grade ≥ 2 was more frequent in patients treated by CRT (56%) compared to IMRT (30%) (p = 0.008). Logistic regression analysis showed a correlation between acute diarrhoea and bowel cavity dose-volume parameters in the 10-50 Gy range. Severe late toxicity (grade ≥ 3) was recorded in 10% of the total cohort, with no statistical difference between the IMRT and CRT groups. Patients treated with IMRT for bladder cancer had significantly less acute diarrhoea compared to those treated with CRT, but there was no significant difference in late morbidity between the groups. The risk of acute diarrhoea was related to the volume of bowel irradiated.

  3. A type II first branchial cleft cyst masquerading as an infected parotid Warthin's tumor.

    Science.gov (United States)

    Chen, Meng-Feng; Ueng, Shir-Hwa; Jung, Shih-Ming; Chen, Yao-Liang; Chang, Kai-Ping

    2006-01-01

    The diagnosis of a parotid mass usually depends on thorough history taking and physical examination. Diagnostic modalities, including ultrasonographic examinations, computed tomography and magnetic resonance images, may also provide substantial information but their accuracy for diagnosis is sometimes questionable, especially in differentiating some rare neoplasms. First branchial cleft cysts (FBCCs) are rare causes of parotid swelling and comprise less than 1% of all branchial anomalies. They are frequently misdiagnosed due to their rarity and unfamiliar clinical signs and symptoms. We present a case of type II FBCC masquerading as an infected parotid Warthin's tumor. We also review the clinical signs and symptoms of FBCCs in order to remind clinicians that this rare branchial anomaly can mimic an infected Warthin's tumor and may be seated in the deep lobe of the parotid gland. By making an accurate pre-operative diagnosis of type II FBCC, we can minimize surgical morbidity and avoid incomplete resection and possible recurrence.

  4. Iodine-131 therapy for parotid oncocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Kosuda, S.; Ishikawa, M.; Tamura, K.; Mukai, M.; Kubo, A.; Hashimoto, S.

    1988-06-01

    We present a rare case of a patient with coexisting parotid oncocytoma and chronic thyroiditis who received two therapeutic doses of (/sup 131/I)iodide for a recurrent oncocytoma (oxyphilic granular cell adenoma), resulting in a definite reduction in tumor volume. We suggest that radioiodine therapy for a recurrent oncocytoma is an effective form of tumor therapy.

  5. Phase II study evaluating consolidation whole abdominal intensity-modulated radiotherapy (IMRT in patients with advanced ovarian cancer stage FIGO III - The OVAR-IMRT-02 Study

    Directory of Open Access Journals (Sweden)

    Eichbaum Michael H

    2011-01-01

    Full Text Available Abstract Background The prognosis for patients with advanced FIGO stage III epithelial ovarian cancer remains poor despite the aggressive standard treatment, consisting of maximal cytoreductive surgery and platinum-based chemotherapy. The median time to recurrence is less than 2 years, with a 5-years survival rate of -20-25%. Recurrences of the disease occur mostly intraperitoneally. Ovarian cancer is a radiosensitive tumor, so that the use of whole abdominal radiotherapy (WAR as a consolidation therapy would appear to be a logical strategy. WAR used to be the standard treatment after surgery before the chemotherapy era; however, it has been almost totally excluded from the treatment of ovarian cancer during the past decade because of its high toxicity. Modern intensity-modulated radiation therapy (IMRT has the potential of sparing organs at risk like kidneys, liver, and bone marrow while still adequately covering the peritoneal cavity with a homogenous dose. Our previous phase I study showed for the first time the clinical feasibility of intensity-modulated WAR and pointed out promising results concerning treatment tolerance. The current phase-II study succeeds to the phase-I study to further evaluate the toxicity of this new treatment. Methods/design The OVAR-IMRT-02 study is a single-center one arm phase-II trial. Thirty seven patients with optimally debulked ovarian cancer stage FIGO III having a complete remission after chemotherapy will be treated with intensity-modulated WAR as a consolidation therapy. A total dose of 30 Gy in 20 fractions of 1.5 Gy will be applied to the entire peritoneal cavity including the liver surface and the pelvic and para-aortic node regions. Organ at risk are kidneys, liver (except the 1 cm-outer border, heart, vertebral bodies and pelvic bones. Primary endpoint is tolerability; secondary objectives are toxicity, quality of life, progression-free and overall survival. Discussion Intensity-modulated WAR provides

  6. Phase II study evaluating consolidation whole abdominal intensity-modulated radiotherapy (IMRT) in patients with advanced ovarian cancer stage FIGO III - The OVAR-IMRT-02 Study

    International Nuclear Information System (INIS)

    Rochet, Nathalie; Debus, Juergen; Kieser, Meinhard; Sterzing, Florian; Krause, Sonja; Lindel, Katja; Harms, Wolfgang; Eichbaum, Michael H; Schneeweiss, Andreas; Sohn, Christof

    2011-01-01

    The prognosis for patients with advanced FIGO stage III epithelial ovarian cancer remains poor despite the aggressive standard treatment, consisting of maximal cytoreductive surgery and platinum-based chemotherapy. The median time to recurrence is less than 2 years, with a 5-years survival rate of -20-25%. Recurrences of the disease occur mostly intraperitoneally. Ovarian cancer is a radiosensitive tumor, so that the use of whole abdominal radiotherapy (WAR) as a consolidation therapy would appear to be a logical strategy. WAR used to be the standard treatment after surgery before the chemotherapy era; however, it has been almost totally excluded from the treatment of ovarian cancer during the past decade because of its high toxicity. Modern intensity-modulated radiation therapy (IMRT) has the potential of sparing organs at risk like kidneys, liver, and bone marrow while still adequately covering the peritoneal cavity with a homogenous dose. Our previous phase I study showed for the first time the clinical feasibility of intensity-modulated WAR and pointed out promising results concerning treatment tolerance. The current phase-II study succeeds to the phase-I study to further evaluate the toxicity of this new treatment. The OVAR-IMRT-02 study is a single-center one arm phase-II trial. Thirty seven patients with optimally debulked ovarian cancer stage FIGO III having a complete remission after chemotherapy will be treated with intensity-modulated WAR as a consolidation therapy. A total dose of 30 Gy in 20 fractions of 1.5 Gy will be applied to the entire peritoneal cavity including the liver surface and the pelvic and para-aortic node regions. Organ at risk are kidneys, liver (except the 1 cm-outer border), heart, vertebral bodies and pelvic bones. Primary endpoint is tolerability; secondary objectives are toxicity, quality of life, progression-free and overall survival. Intensity-modulated WAR provides a new promising option in the consolidation treatment of

  7. SU-F-T-342: Dosimetric Constraint Prediction Guided Automatic Mulit-Objective Optimization for Intensity Modulated Radiotherapy

    International Nuclear Information System (INIS)

    Song, T; Zhou, L; Li, Y

    2016-01-01

    Purpose: For intensity modulated radiotherapy, the plan optimization is time consuming with difficulties of selecting objectives and constraints, and their relative weights. A fast and automatic multi-objective optimization algorithm with abilities to predict optimal constraints and manager their trade-offs can help to solve this problem. Our purpose is to develop such a framework and algorithm for a general inverse planning. Methods: There are three main components contained in this proposed multi-objective optimization framework: prediction of initial dosimetric constraints, further adjustment of constraints and plan optimization. We firstly use our previously developed in-house geometry-dosimetry correlation model to predict the optimal patient-specific dosimetric endpoints, and treat them as initial dosimetric constraints. Secondly, we build an endpoint(organ) priority list and a constraint adjustment rule to repeatedly tune these constraints from their initial values, until every single endpoint has no room for further improvement. Lastly, we implement a voxel-independent based FMO algorithm for optimization. During the optimization, a model for tuning these voxel weighting factors respecting to constraints is created. For framework and algorithm evaluation, we randomly selected 20 IMRT prostate cases from the clinic and compared them with our automatic generated plans, in both the efficiency and plan quality. Results: For each evaluated plan, the proposed multi-objective framework could run fluently and automatically. The voxel weighting factor iteration time varied from 10 to 30 under an updated constraint, and the constraint tuning time varied from 20 to 30 for every case until no more stricter constraint is allowed. The average total costing time for the whole optimization procedure is ∼30mins. By comparing the DVHs, better OAR dose sparing could be observed in automatic generated plan, for 13 out of the 20 cases, while others are with competitive

  8. SU-F-T-342: Dosimetric Constraint Prediction Guided Automatic Mulit-Objective Optimization for Intensity Modulated Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Song, T; Zhou, L [Southern Medical University, Guangzhou, Guangdong (China); Li, Y [Beihang University, Beijing, Beijing (China)

    2016-06-15

    Purpose: For intensity modulated radiotherapy, the plan optimization is time consuming with difficulties of selecting objectives and constraints, and their relative weights. A fast and automatic multi-objective optimization algorithm with abilities to predict optimal constraints and manager their trade-offs can help to solve this problem. Our purpose is to develop such a framework and algorithm for a general inverse planning. Methods: There are three main components contained in this proposed multi-objective optimization framework: prediction of initial dosimetric constraints, further adjustment of constraints and plan optimization. We firstly use our previously developed in-house geometry-dosimetry correlation model to predict the optimal patient-specific dosimetric endpoints, and treat them as initial dosimetric constraints. Secondly, we build an endpoint(organ) priority list and a constraint adjustment rule to repeatedly tune these constraints from their initial values, until every single endpoint has no room for further improvement. Lastly, we implement a voxel-independent based FMO algorithm for optimization. During the optimization, a model for tuning these voxel weighting factors respecting to constraints is created. For framework and algorithm evaluation, we randomly selected 20 IMRT prostate cases from the clinic and compared them with our automatic generated plans, in both the efficiency and plan quality. Results: For each evaluated plan, the proposed multi-objective framework could run fluently and automatically. The voxel weighting factor iteration time varied from 10 to 30 under an updated constraint, and the constraint tuning time varied from 20 to 30 for every case until no more stricter constraint is allowed. The average total costing time for the whole optimization procedure is ∼30mins. By comparing the DVHs, better OAR dose sparing could be observed in automatic generated plan, for 13 out of the 20 cases, while others are with competitive

  9. Fixed or adapted conditioning intensity for repeated conditioned pain modulation.

    Science.gov (United States)

    Hoegh, M; Petersen, K K; Graven-Nielsen, T

    2017-12-29

    Aims Conditioned pain modulation (CPM) is used to assess descending pain modulation through a test stimulation (TS) and a conditioning stimulation (CS). Due to potential carry-over effects, sequential CPM paradigms might alter the intensity of the CS, which potentially can alter the CPM-effect. This study aimed to investigate the difference between a fixed and adaptive CS intensity on CPM-effect. Methods On the dominant leg of 20 healthy subjects the cuff pressure detection threshold (PDT) was recorded as TS and the pain tolerance threshold (PTT) was assessed on the non-dominant leg for estimating the CS. The difference in PDT before and during CS defined the CPM-effect. The CPM-effect was assessed four times using a CS with intensities of 70% of baseline PTT (fixed) or 70% of PTT measured throughout the session (adaptive). Pain intensity of the conditioning stimulus was assessed on a numeric rating scale (NRS). Data were analyzed with repeated-measures ANOVA. Results No difference was found comparing the four PDTs assessed before CSs for the fixed and the adaptive paradigms. The CS pressure intensity for the adaptive paradigm was increasing during the four repeated assessments (P CPM-effect was higher using the fixed condition compared with the adaptive condition (P CPM paradigms using a fixed conditioning stimulus produced an increased CPM-effect compared with adaptive and increasing conditioning intensities.

  10. Quantitative gammagraphie and sialometry of the parotid in patients irradiated in the cervico-facial area

    International Nuclear Information System (INIS)

    Gaztelu, R.; Rodriguez, R.; Fernandez Garcia, M.C.; Cobo Plana, J.

    1988-01-01

    Changes in parotid function in patients presenting with tumors of the cervico-facial area, in whom the whole of the parotid gland was within the irradiation field were assesse by means of saliva secretion determinations and quantitative gammagrams of the parotid. The following aims were pursued: a) To evaluate and to compare the sensitivity of both methods. b) To compare the radiotracer agent uptake in normal parotid glands, as well as the variations that occur in relation to the number of received, and with the time duration of irradiation. The conclusions were as follows: -Both methods are sensitive, but the gammagraphic method has the advantages of being non-invasive, easily performed and not causing discomfort to the patient. -The quantification of the parotied uptake in a control group of patients, as compared with the variations occuring in relation to the number of rads racived, show that at the end of the treatment with 5.000 rads, uptake reaches 15% of that of the control group. One year later, function is very little restored, not reaching 20% of that of the control group. -Decrease of both parotid secretion and uptake is directly proportional to the dose received. (Author)

  11. Induction of parotitis by fine-needle aspiration in parotid Warthin's tumor.

    Science.gov (United States)

    Suzuki, Kensuke; Iwai, Hiroshi; Kaneko, Toshihiko; Sakaguchi, Mariko; Hoshino, Shoichi; Inaba, Muneo

    2009-08-01

    To estimate parotitis caused by fine-needle aspiration (FNA) in parotid Warthin tumor. Case series with chart review. Hospital records were reviewed for 104 parotid tumors (103 patients) including 35 Warthin tumors, which underwent FNA within our department. Three patients with four Warthin tumors among them noticed parotid pain, swelling, and abscess formation as a consequence of acute parotitis after FNA. Examinations of the materials obtained from tumor puncture or drainage before the start of antibiotic therapy showed no bacterial association in any patient. Two of the patients with Warthin tumor underwent parotidectomy, and the surgical specimens indicated histopathological changes with necrosis, abscess, granuloma, and the infiltration of inflammatory cells including Langhans-type multinucleated giant cells. It is conceivable that Warthin tumor bears the characteristics of inflammation induced by the FNA procedure without any relation to infection. Therefore, it may be better to avoid routine FNA and give priority to diagnostic imagings over FNA in the diagnosis of tumors strongly suspected as Warthin tumor.

  12. Parotid radiosensitivity changes: a temporal relation to glandular circadian rhythms

    International Nuclear Information System (INIS)

    El-Mofty, S.K.; Hovenga, T.L.; Russell, J.E.; Simmons, D.J.

    1982-01-01

    The radiosensitivity of the rat parotid gland to X-radiation increased considerably towards the end of the daily light span (0800-2000 hours) and to a lesser extent before the onset of that period. The major sensitivity peak occurred at 1600 hours and coincides with a diurnal nadir in the rates of protein and RNA synthesis. The minor peak occurred at 0400 hours and was temporally related to a daily period of maximal secretory activity. It is suggested that suboptimal repair and secretion-linked cellular perturbations might contribute to the pathogenesis of the circadian increases in radiosensitivity of parotid cells. (author)

  13. Functional imaging of parotid glands: Diffusion-weighted echo-planar MRI before and after stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Habermann, C.R.; Cramer, M.C.; Gossrau, P.; Adam, G. [University Hospital Hamburg-Eppendorf (Germany). Department of Diagnostic and Interventional Radiology; Graessner, J. [Siemens AG, Hamburg (Germany). Medical Solutions; Reitmeier, F.; Jaehne, M. [University Hospital Hamburg-Eppendorf (Germany). Department of Oto-, Rhino-, Laryngology; Fiehler, J. [University Hospital Hamburg-Eppendorf (Germany). Department of Neuroradiology; Schoder, V. [University Hospital Hamburg-Eppendorf (Germany). Institute for Medical Biometry and Epidemiology

    2004-10-01

    Purpose: To investigate the feasibility of diffusion-weighted (DW) echo-planar imaging (EPI) for measuring different functional conditions of the parotid gland and to compare different measurement approaches. Materials and Methods: Parotid glands of 27 healthy volunteers were examined with a DW EPI sequence (TR 1,500 msec, TE 77 msec, field-of-view 250 x 250 mm, pixel size 2.10 x 1.95 mm, section thickness 5 mm) before and after oral stimulation with commercially available lemon juice. The b factors used were 0, 500, and 1,000 sec/mm{sup 2}. Apparent diffusion coefficient (ADC) maps were digitally transferred to MRIcro (Chris Rorden, University of Nottingham, Great Britain) and evaluated with a manually placed circular region of interest (ROI) containing 100-200 pixel. Additional ROIs including the entire parotid gland were placed on either side. The results of both measurements were compared, using the Student's t test based on the median ADC values for each person. A two-tailed p-value of less than.05 was determined to indicate statistical significance. To compare both measurement approaches, the Pearson's correlation coefficient (r) was calculated. Results: Diffusion-weighted echo-planar MR imaging successfully visualized the parotid gland of all volunteers. In a first step, the median ADC value per person was computed. Using ROIs of 100-200 pixels, the mean was calculated to be 1.08 x 10{sup -3} mm{sup 2}/sec{+-}0.12 x 10{sup -3} mm{sup 2}/sec for both parotid glands prior to simulation. After stimulation, the mean ADC was measured at 1.15 x 10{sup -3} mm{sup 2}/sec{+-}0.11 x 10{sup -3} mm{sup 2}/sec for both parotid glands. Evaluating the entire parotid gland, the ADC was 1.12 x 10{sup -3} mm{sup 2}/sec{+-}0.08 x 10{sup -3} mm{sup 2}/sec prior to simulation, whereas the ADC increased to 1.18 x 10{sup -3} mm{sup 2}/sec{+-}0.09 x 10{sup -3} mm{sup 2}/sec after simulation with lemon juice. For both types of measurements, the increase in ADC after

  14. Adenocarcinoma of the parotid gland with calcification

    Energy Technology Data Exchange (ETDEWEB)

    Song, Haeng Eun; Koh, Kwang Joon [School of Dentistry, Chonbuk National University, Chonju (Korea, Republic of)

    2002-03-15

    A 78-year-old woman was referred to Chonbuk National University Dental Hospital complaining of facial palsy and palpable mass on the right parotid gland area. Clinical examination showed non-specific findings of the intraoral region, but showed asymmetrical facial appearance. Panoramic view showed a large amorphous calcified mass on the posterior to the mandibular ramus and thin cortical plate of the posterior ramus. Sialogram showed constriction of the main duct and no further filling of striated, intercalated ducts and parenchymal areas. CT scans demonstrated an irregular, infiltrating mass with slight enhancement in the right parotid gland. The mass showed necrotic areas and calcifications. Bone scan showed marked accumulation of {sup 99m}Tc-MDP on the right posterior maxilla. Microscopic findings demonstrated the minimal morphologic alterations and rare mitotic figures within tumor cells, and diagnosed as adenocarcinoma (NOS, Grade II). This report could be aid in the diagnosis of calcified lesions of the salivary gland.

  15. Adenocarcinoma of the parotid gland with calcification

    International Nuclear Information System (INIS)

    Song, Haeng Eun; Koh, Kwang Joon

    2002-01-01

    A 78-year-old woman was referred to Chonbuk National University Dental Hospital complaining of facial palsy and palpable mass on the right parotid gland area. Clinical examination showed non-specific findings of the intraoral region, but showed asymmetrical facial appearance. Panoramic view showed a large amorphous calcified mass on the posterior to the mandibular ramus and thin cortical plate of the posterior ramus. Sialogram showed constriction of the main duct and no further filling of striated, intercalated ducts and parenchymal areas. CT scans demonstrated an irregular, infiltrating mass with slight enhancement in the right parotid gland. The mass showed necrotic areas and calcifications. Bone scan showed marked accumulation of 99m Tc-MDP on the right posterior maxilla. Microscopic findings demonstrated the minimal morphologic alterations and rare mitotic figures within tumor cells, and diagnosed as adenocarcinoma (NOS, Grade II). This report could be aid in the diagnosis of calcified lesions of the salivary gland.

  16. Primary clear cell carcinoma of parotid gland: Case report and review of literature.

    Science.gov (United States)

    Rodríguez, Marta Saldaña; Reija, Maria Fe García; Rodilla, Irene González

    2013-01-01

    Clear cell carcinoma (CCC) is a rare low-grade carcinoma that represents only 1% to 2% of all salivary glands tumors. The finding of a clear cell tumor in a parotid gland involves the necessity of differential diagnosis between primary clear cell parotid tumors and metastases, mainly from kidney. The biological behavior is not very aggressive and development, which is very slow, is usually asymptomatic and indeed, the tumor often reaches considerable dimensions before being diagnosed. The treatment of choice is the surgical excision. There are rare cases of local recurrence and distant metastases. The aim of this article is to report a primary CCC in the parotid gland that microscopically closely resembled a metastatic CCC of renal origin, making microscopic differentiation difficult.

  17. Perfusion characteristics of late radiation injury of parotid glands: quantitative evaluation with dynamic contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Juan, Chun-Jung; Chen, Cheng-Yu.; Hsueh, Chun-Jen; Huang, Guo-Shu; Jen, Yee-Min; Liu, Hua-Shan; Wang, Chao-Ying; Chung, Hsiao-Wen; Liu, Yi-Jui; Chou, Yu-Ching; Chai, Yao-Te

    2009-01-01

    We aimed to quantitatively investigate the alteration of parotid perfusion after irradiation using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) based on a two-compartment tracer kinetic model. This study enrolled 19 patients (53.2±14.9 years) treated by head and neck radiotherapy and 19 age-relevant and sex-matched subjects as a control group. Perfusion parameters (K el , k 21 and A) of parotid glands were analyzed based on the Brix model from T1-weighted DCE-MRI. Suitability of the Brix model was evaluated via Monte Carlo simulation for the goodness-of-fit. Analysis of nonlinear goodness-of-fit showed that the Brix model is appropriate in evaluating the parotid perfusion (R 2 = 0.938±0.050). The irradiated parotid glands showed significantly lower K el (P 21 (P < 0.05) and consequently significantly higher value of peak enhancement (P<0.0005) and time-to-peak (P<0.0005) compared with non-irradiated ones, suggestive of gradual and prolonged accumulation and delayed wash-out of contrast agent due to increased extracellular extravascular space and decreased vascular permeability in the irradiated glands. Linear regression analysis showed dose-dependent perfusion changes of the irradiated parotid glands. We conclude that quantitative DCE-MRI is a potential tool in investigating parotid gland perfusion changes after radiotherapy. (orig.)

  18. Quality assurance of intensity-modulated radiation therapy.

    Science.gov (United States)

    Palta, Jatinder R; Liu, Chihray; Li, Jonathan G

    2008-01-01

    The current paradigm for the quality assurance (QA) program for intensity-modulated radiation therapy (IMRT) includes QA of the treatment planning system, QA of the delivery system, and patient-specific QA. Although the IMRT treatment planning and delivery system is the same as for conventional three-dimensional conformal radiation therapy, it has more parameters to coordinate and verify. Because of complex beam intensity modulation, each IMRT field often includes many small irregular off-axis fields, resulting in isodose distributions for each IMRT plan that are more conformal than those from conventional treatment plans. Therefore, these features impose a new and more stringent set of QA requirements for IMRT planning and delivery. The generic test procedures to validate dose calculation and delivery accuracy for both treatment planning and IMRT delivery have to be customized for each type of IMRT planning and delivery strategy. The rationale for such an approach is that the overall accuracy of IMRT delivery is incumbent on the piecewise uncertainties in both the planning and delivery processes. The end user must have well-defined evaluation criteria for each element of the planning and delivery process. Such information can potentially be used to determine a priori the accuracy of IMRT planning and delivery.

  19. Quality Assurance of Intensity-Modulated Radiation Therapy

    International Nuclear Information System (INIS)

    Palta, Jatinder R.; Liu, Chihray; Li, Jonathan G.

    2008-01-01

    The current paradigm for the quality assurance (QA) program for intensity-modulated radiation therapy (IMRT) includes QA of the treatment planning system, QA of the delivery system, and patient-specific QA. Although the IMRT treatment planning and delivery system is the same as for conventional three-dimensional conformal radiation therapy, it has more parameters to coordinate and verify. Because of complex beam intensity modulation, each IMRT field often includes many small irregular off-axis fields, resulting in isodose distributions for each IMRT plan that are more conformal than those from conventional treatment plans. Therefore, these features impose a new and more stringent set of QA requirements for IMRT planning and delivery. The generic test procedures to validate dose calculation and delivery accuracy for both treatment planning and IMRT delivery have to be customized for each type of IMRT planning and delivery strategy. The rationale for such an approach is that the overall accuracy of IMRT delivery is incumbent on the piecewise uncertainties in both the planning and delivery processes. The end user must have well-defined evaluation criteria for each element of the planning and delivery process. Such information can potentially be used to determine a priori the accuracy of IMRT planning and delivery

  20. Forward-planned intensity modulated radiation therapy using a cobalt source: A dosimetric study in breast cancer

    Directory of Open Access Journals (Sweden)

    Savino Cilla

    2013-01-01

    Full Text Available This analysis evaluates the feasibility and dosimetric results of a simplified intensity-modulated radiotherapy (IMRT treatment using a cobalt-therapy unit for post-operative breast cancer. Fourteen patients were included. Three plans per patient were produced by a cobalt-60 source: A standard plan with two wedged tangential beams, a standard tangential plan optimized without the use of wedges and a plan based on the forward-planned "field-in-field" IMRT technique (Co-FinF where the dose on each of the two tangential beams was split into two different segments and the two segments weight was determined with an iterative process. For comparison purposes, a 6-MV photon standard wedged tangential treatment plan was generated. D mean , D 98% , D 2% , V 95% , V 107%, homogeneity, and conformity indices were chosen as parameters for comparison. Co-FinF technique improved the planning target volume dose homogeneity compared to other cobalt-based techniques and reduced maximum doses (D 2% and high-dose volume (V 110% . Moreover, it showed a better lung and heart dose sparing with respect to the standard approach. The higher dose homogeneity may encourage the adoption of accelerated-hypofractionated treatments also with the cobalt sources. This approach can promote the spread of breast conservative treatment in developing countries.

  1. Density variation of parotid glands during IMRT for head–neck cancer: Correlation with treatment and anatomical parameters

    International Nuclear Information System (INIS)

    Fiorino, Claudio; Rizzo, Giovanna; Scalco, Elisa; Broggi, Sara; Belli, Maria Luisa; Dell’Oca, Italo; Dinapoli, Nicola; Ricchetti, Francesco; Rodriguez, Aldo Mejia; Di Muzio, Nadia; Calandrino, Riccardo; Sanguineti, Giuseppe; Valentini, Vincenzo; Cattaneo, Giovanni Mauro

    2012-01-01

    Purpose: Measuring parotid density changes in patients treated with IMRT for head–neck cancer (HNC) and assessing correlation with treatment-related parameters. Patients and materials: Data of 84 patients treated with IMRT for different HNC were pooled from three institutions. Parotid deformation and average Hounsfield number changes (ΔHU) were evaluated through MVCT (with Helical Tomotherapy) or diagnostic kVCT images taken at the treatment start/end. Parotids were delineated in the first image and propagated to the last using a previously validated algorithm based on elastic registration. The correlation between ΔHU and several treatment-related parameters was tested; then, logistic uni- and multi-variate analyses taking “large” ΔHU as end-point were carried out. Due to the better image quality, analyses were repeated considering only kVCT data. Results: ΔHU was negative in 116/168 parotids (69%; for kVCT patients: 72/92, 78%). The average ΔHU was significantly different from zero (−7.3, 0.20–0.25 HU/fraction, p m ean), and with neck thickness variation; these correlations were much stronger for kVCT data. Logistic analyses considering ΔHU m ean < 0.68) and initial neck thickness to be the most predictive variables (p < 0.0005, AUC = 0.683; AUC = 0.776 for kVCT); the odd ratio of large vs moderate/small parotid deformation was 3.8 and 8.0 for the whole and the kVCT population respectively. Conclusions: Parotid density reduced in most patients during IMRT and this phenomenon was highly correlated with parotid deformation. The individual assessment of density changes was highly reliable just with diagnostic KvCT. Density changes should be considered as an additional objective measurement of early parotid radiation-induced modifications; further research is warranted.

  2. Early evaluation of radiation-induced parotid damage in patients with nasopharyngeal carcinoma by T2 mapping and mDIXON Quant imaging: initial findings.

    Science.gov (United States)

    Zhou, Nan; Chu, Chen; Dou, Xin; Chen, Weibo; He, Jian; Yan, Jing; Zhou, Zhengyang; Yang, Xiaofeng

    2018-02-08

    Radiation-induced parotid damage is a common complication in patients with nasopharyngeal carcinoma (NPC) treated with radiotherapy to head and neck region, which severely reduce the life quality of those patients. The aim of this study was to early evaluate the changes of irradiated parotid glands with T2 mapping and mDIXON Quant imaging. Forty-one patients with NPC underwent conventional magnetic resonance imaging for nasopharynx and neck, and T2 mapping and mDIXON Quant imaging for bilateral parotid glands within 2 weeks before radiotherapy (pre-RT), 5 weeks after the beginning of radiotherapy (mid-RT), and 4 weeks after radiotherapy (post-RT). Parotid volume, T2 values, fat fraction (FF) values, and mean radiation dose were recorded and analyzed. From pre-RT to mid-RT, parotid volume decreased (atrophy rate, 27.0 ± 11.5%), while parotid T2 and FF values increased (change rate, 6.0 ± 6.2% for T2 value and 9.1 ± 9.9% for FF value) significantly. From mid-RT to post-RT, parotid T2 value continuously increased (change rate, 4.6 ± 7.7%), but parotid FF value decreased (change rate, - 9.9 ± 18.2%) significantly. Change rate of parotid T2 value significantly correlated with parotid atrophy rate from pre-RT to post-RT (r = 0.313, P = 0.027). Multiple linear regression analysis showed that parotid T2 value (standardized coefficient [SC] = - 0.259, P = 0.001) and FF value (SC = - 0.320, P = 0.014) negatively correlated with parotid volume, while parotid T2 value positively correlated with MR scan time point (SC = 0.476, P = 0.001) significantly. Parotid T2 and FF values showed excellent reproducibility (intraclass correlation coefficient, 0.935-0.992). T2 mapping and mDIXON Quant imaging is useful for noninvasive evaluation of radiation-induced parotid damage.

  3. Introducing the Jacobian-volume-histogram of deforming organs: application to parotid shrinkage evaluation

    International Nuclear Information System (INIS)

    Fiorino, Claudio; Maggiulli, Eleonora; Broggi, Sara; Cattaneo, Giovanni Mauro; Calandrino, Riccardo; Liberini, Simone; Faggiano, Elena; Rizzo, Giovanna; Dell'Oca, Italo; Di Muzio, Nadia

    2011-01-01

    The Jacobian of the deformation field of elastic registration between images taken during radiotherapy is a measure of inter-fraction local deformation. The histogram of the Jacobian values (Jac) within an organ was introduced (JVH-Jacobian-volume-histogram) and first applied in quantifying parotid shrinkage. MVCTs of 32 patients previously treated with helical tomotherapy for head-neck cancers were collected. Parotid deformation was evaluated through elastic registration between MVCTs taken at the first and last fractions. Jac was calculated for each voxel of all parotids, and integral JVHs were calculated for each parotid; the correlation between the JVH and the planning dose-volume histogram (DVH) was investigated. On average, 82% (±17%) of the voxels shrinks (Jac 50% (Jac < 0.5). The best correlation between the DVH and the JVH was found between V10 and V15, and Jac < 0.4-0.6 (p < 0.01). The best constraint predicting a higher number of largely compressing voxels (Jac0.5<7.5%, median value) was V15 ≥ 75% (OR: 7.6, p = 0.002). Jac and the JVH are promising tools for scoring/modelling toxicity and for evaluating organ/contour variations with potential applications in adaptive radiotherapy.

  4. Visualizing form and function in organotypic slices of the adult mouse parotid gland.

    Science.gov (United States)

    Warner, Jennifer D; Peters, Christian G; Saunders, Rudel; Won, Jong Hak; Betzenhauser, Matthew J; Gunning, William T; Yule, David I; Giovannucci, David R

    2008-09-01

    An organotypic slice preparation of the adult mouse parotid salivary gland amenable to a variety of optical assessments of fluid and protein secretion dynamics is described. The semi-intact preparation rendered without the use of enzymatic treatment permitted live-cell imaging and multiphoton analysis of cellular and supracellular signals. Toward this end we demonstrated that the parotid slice is a significant addition to the repertoire of tools available to investigators to probe exocrine structure and function since there is currently no cell culture system that fully recapitulates parotid acinar cell biology. Importantly, we show that a subpopulation of the acinar cells of parotid slices can be maintained in short-term culture and retain their morphology and function for up to 2 days. This in vitro model system is a significant step forward compared with enzymatically dispersed acini that rapidly lose their morphological and functional characteristics over several hours, and it was shown to be long enough for the expression and trafficking of exogenous protein following adenoviral infection. This system is compatible with a variety of genetic and physiological approaches used to study secretory function.

  5. Incidental focal FDG uptake in the parotid glands on PET/CT in patients with head and neck malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Lan; Yoon, Dae Young; Lim, Kyoung Ja; Yun, Eun Joo; Cho, Young Kwon [Hallym University College of Medicine, Department of Radiology, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of); Baek, Sora [Hallym University College of Medicine, Department of Nuclear Medicine, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of); Bae, Woo Jin; Chung, Eun Jae; Kwon, Kee Hwan [Hallym University College of Medicine, Department of Otorhinolaryngology, Ilsong Memorial Institute of Head and Neck Cancer, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of)

    2015-01-15

    To evaluate the prevalence and clinical significance of focal parotid lesions identified by {sup 18} F- FDG PET/CT in patients with nonparotid head and neck malignancies. From 3,638 PET/CT examinations using {sup 18} F-FDG conducted on 1,342 patients with nonparotid head and neck malignancies, we retrospectively identified patients showing incidental focal FDG uptake in the parotid glands. The diagnosis of parotid lesions was confirmed histopathologically or on imaging follow-up. Patient demographics, clinical features, maximum standardized uptake value (SUV{sub max}) on PET images, size and attenuation on corresponding contrast-enhanced CT images were assessed and correlated with the final diagnosis. The prevalence of incidental focal parotid FDG uptake on PET/CT was 2.1 % (95 % CI 1.4 - 3.0 %). Among 21 patients with focal parotid lesions confirmed histologically or on imaging follow-up, 7 (33.3 %) had malignant lesions (all metastases) and 14 (66.7 %) had benign lesions (four pleomorphic adenomas, two Warthin's tumours, one benign lymph node, one granulomatous lesion, six lesions without histopathological confirmation). There were no significant differences in age, sex, SUV{sub max} or CT findings between patients with benign and those with malignant lesions. Focal parotid FDG uptake on PET/CT in patients with head and neck malignancy warrants further investigations to ensure adequate therapy for incidental parotid lesions. (orig.)

  6. Congenital tri-cavernous hemangiomas of the right buccal region, right accessory parotid gland, and masseter muscle region.

    Science.gov (United States)

    Yang, Tao; Gu, Yongchun; Zhang, Li; Hua, Zequan

    2014-03-01

    We report a rare case of congenital tri-cavernous hemangiomas of the right buccal region, right accessory parotid gland, and masseter muscle region in an adult. The patient, a 25-year-old woman, complained of 3 masses in her right midcheek. Ultrasonographic and computed tomographic findings showed an irregular-shaped mass (multiple calcifications) with a well-defined margin in the masseter muscle region, an ellipse-shaped mass (multiple calcifications) with a well-defined margin in the right buccal region, and a comma-shaped mass (no calcifications) with a well-defined margin separate from the parotid gland in the right accessory parotid gland region. These iconographic findings suggested that the masses were all hemangiomas separately originating from the parotid gland, accessory parotid gland, and masseter muscle. The masses were completely removed through a standard parotid incision without postoperative facial palsy, skin deformity, and difficulty in secreting saliva. Findings from histologic examination of the tumor revealed multiple, thin-walled, and dilated blood vessels, confirming the diagnosis of cavernous hemangiomas. Ultrasonographic and computed tomographic findings were extremely useful in diagnosing the mass/masses as hemangioma before surgery, clarifying relationships between the mass and adjacent structures, and determining the surgical approach to the mass/masses.

  7. Sonographic Assessment of Parotid and Submandibular Glands in Patients Undergoing 3D Conformal Radiotherapy

    Directory of Open Access Journals (Sweden)

    Johari M

    2016-06-01

    Full Text Available The aim of this study was to evaluate sonographic changes in parotid and submandibular salivary glands in patients undergoing radiotherapy for head and neck malignancies. In addition, salivary changes subsequent to radiotherapy were evaluated objectively and subjectively. Twenty patients(13males and 7females with head and neck malignancies, who had been referred to the Radiotherapy/Oncology Department of the Shahid Madani Hospital in Tabriz, Iran, were included in the study. Length, width, echotexture, echogenicity and margins of parotid and submandibular glands were evaluated before and after radiotherapy using sonography. Peak-systolic velocity(PSV,end-diastolic velocity(EDV and resistive index(RI were also assessed by Doppler sonography. Xerostomia subsequent to radiotherapy was evaluated with the use of two techniques: patients’ self-reported scoring and objective measurement of resting saliva. There was a significant decrease in the width of the parotid gland after radiotherapy compared to baseline(P=0.005.Although the length of the parotid gland and the dimensions of submandibular gland decrease, the differences were not significant. In addition, the echogenicity, echotexture and the margin of the glands change to hypoechoic, heterogenic and irregular, respectively, subsequent to radiotherapy. The Doppler technique showed decrease in PSV and RI and an increase in EDV; however, only the decrease in RI in the submandibular gland was statistically significant(P=0.002.The results showed a significant decrease in salivary flow after radiotherapy(P<0.001.In addition, based on the patients reports, the severity of xerostomia increased significantly after radiotherapy(P<0.001. Songraphic changes of parotid and submandibular glands after radiotherapy should be considered in ultrasound examinations. The damages to the parotid and submandibular glands had significant influence in patient post 3D-CRT.

  8. Parotid lymphomas – clinical and computed tomographic imaging ...

    African Journals Online (AJOL)

    mass in the parotid region.3-5 Many centres complement this approach with ancillary investigations ... radiotherapy, alone or in combination.2 Surgical intervention for lymphoma is limited to a purely diagnostic role.9 It is therefore desirable to ...

  9. Congenital agenesis of unilateral parotid gland with ipsilateral type I first branchial cleft anomaly: A rare presentation

    OpenAIRE

    Tripti Maithani; Apoorva Pandey; Seema Acharya

    2014-01-01

    Aim: To report a rare case of unilateral parotid agenesis with ipsilateral type I first branchial cleft anomaly. Material and methods: A case study with special emphasis on the embryology, outlining the complex developmental process of parotid and branchial arches and highlighting the probable reason for development of such anomalies. Results: The literature states that unilateral parotid agenesis is a rare entity with few reported cases occurring solely or in conjunction with other hea...

  10. la tumeur de warthin de la parotide : a propos de 11 cas

    African Journals Online (AJOL)

    9 mai 2013 ... Nodule de densité tissulaire à contours nets du pôle infé- rieur de la glande parotide gauche avec prise de contraste hétérogène. L'iRM réalisée pour 3 autres patients a posé le diagnos- tic de tumeur bénigne de la parotide dans tous les cas en montrant des tumeurs aux contours réguliers et biens définis.

  11. Comparison of semi-quantitative parotid scintigraphy with biopsy of labial gland in the patiens with Sjogren's syndrome

    International Nuclear Information System (INIS)

    Huang Jingxiong; He Xiaojiang; Yu Hao; Wu Hua; Chen Guibing

    2009-01-01

    Objective: Labial gland biopsy is one of major diagnostic methods for Sjogren's syndrome (SS). Meanwhile, 99 Tc m O 4 - parotid scintigraphy has been proven useful for the clinical evaluation of SS. This study was performed to investigate the correlation between the two examinations and evaluate the semi-quantitative parotid scintigraphy in the early diagnosis and staging for SS patients.Methods: There were 135 SS patients and 30 normal subjects as control group in this study. They all underwent 99 Tc m O 4 - parotid scintigraphy. Semi-quantitative analyses of parotid scintigraphy were conducted with parameters including maximum accumulation ratio (MAR), maximum secretion ratio (MSR), time interval from stimulation to minimum count (t parotid ), prestimulatory oral activity index (PRI) and poststimulatory oral activity index (POI). For comparison, the biopsy of labial gland was performed in each patient and the pathological se-verity was classified into grade 0, 1, 2, 3, 4 (also defined as subgroups). One-way ANOVA and q-teat were applied for the correlation analyses between the two examinations. Results: There was significant difference between pathological subgroup 3 or subgroup 4 and the control in all the semi-quantitative parameters (q=6.79-38.64, P parotid (r=0.364, P 99 Tc m aO 4 - parotid scintigraphy may be well correlated with the pathological severity of labial gland biopsy in SS patients. Further, the semi-quantitative indices especially PRI and POI may be helpful for the early diagnosis and staging of SS patients. (authors)

  12. Investigation of the feasibility of elective irradiation to neck level Ib using intensity-modulated radiotherapy for patients with nasopharyngeal carcinoma: a retrospective analysis

    International Nuclear Information System (INIS)

    Zhang, Fan; Cheng, Yi-Kan; Li, Wen-Fei; Guo, Rui; Chen, Lei; Sun, Ying; Mao, Yan-Ping; Zhou, Guan-Qun; Liu, Xu; Liu, Li-Zhi; Lin, Ai-Hua; Tang, Ling-Long; Ma, Jun

    2015-01-01

    To assess the feasibility of elective neck irradiation to level Ib in nasopharyngeal carcinoma (NPC) using intensity-modulated radiation therapy (IMRT). We retrospectively analyzed 1438 patients with newly-diagnosed, non-metastatic and biopsy-proven NPC treated with IMRT. Greatest dimension of level IIa LNs (DLN-IIa) ≥ 20 mm and/or level IIa LNs with extracapsular spread (ES), oropharynx involvement and positive bilateral cervical lymph nodes (CLNs) were independently significantly associated with metastasis to level Ib LN at diagnosis. No recurrence at level Ib was observed in the 904 patients without these characteristics (median follow-up, 38.7 months; range, 1.3–57.8 months), these patients were classified as low risk. Level Ib irradiation was not an independent risk factor for locoregional failure-free survival, distant failure-free survival, failure-free survival or overall survival in low risk patients. The frequency of grade ≥ 2 subjective xerostomia at 12 months after radiotherapy was not significantly different between low risk patients who received level Ib-sparing, unilateral level Ib-covering or bilateral level Ib-covering IMRT. Level Ib-sparing IMRT should be safe and feasible for patients without a DLN-IIa ≥ 20 mm and/or level IIa LNs with ES, positive bilateral CLNs or oropharynx involvement at diagnosis. Further investigations based on specific criteria for dose constraints for the submandibular glands are warranted to confirm the benefit of elective level Ib irradiation

  13. Predicting the effects of organ motion on the dose delivered by dynamic intensity modulation

    International Nuclear Information System (INIS)

    Yu, C.X.; Jaffray, David; Martinez, A.A.; Wong, J.W.

    1997-01-01

    Purpose: Computer-optimized treatment plans, aimed to enhance tumor control and reduce normal tissue complication, generally require non-uniform beam intensities. One of the techniques for delivering intensity-modulated beams is the use of dynamic multileaf collimation, where the beam aperture and field shape change during irradiation. When intensity-modulated beams are delivered with dynamic collimation, intra-treatment organ motion may not only cause geometric misses at the field boundaries but also create hot and cold spots in the target. The mechanism for producing such effects has not been well understood. This study analyzes the dosimetric effects of intra-treatment organ motion on dynamic intensity modulation. A numerical method is developed for predicting the intensity distributions in a moving target before dose is delivered with dynamic intensity modulation. Material and Methods: In the numerical algorithm, the change in position and shape of the beam aperture with time were modeled as a three-dimensional 'tunnel', with the shape of the field aperture described in the x-y plane and its temporal position shown in the z-dimension. A point in the target had to be in the tunnel in order to receive irradiation and the dose to the point was proportional to the amount of time that this point stayed in the tunnel. Since each point in the target were analyzed separately, non-rigid body variations could easily be handled. The dependency of the dose variations on all parameters involved, including the speed of collimator motion, the frequency and amplitude of the target motion, and the size of the field segments, was analyzed. The algorithm was verified by irradiating moving phantoms with beams of dynamically modulated intensities. Predictions were also made for a treatment of a thoracic tumor using a dynamic wedge. The changes of target position with time were based on the MRI images of the chest region acquired using fast MRI scans in a cine fashion for a duration

  14. Parotid gland function following accelerated and conventionally fractionated radiotherapy

    International Nuclear Information System (INIS)

    Leslie, M.D.; Dische, S.

    1991-01-01

    The function of parotid glands in patients treated by 3 different schedules of radiotherapy was studied 9 months or more after its conclusion. All had received radiotherapy for a malignancy confined to 1 side of the head and neck region and only the gland on the side of the lesion was in the treatment volume; the contralateral gland acted as an internal control. Saliva was selectively collected from the parotid glands and the stimulated flow rate and pH of the saliva determined. Flow rates were expressed in each case as a percentage of that of the contralateral ('untreated') gland. Twelve glands that had received conventionally fractionated radiotherapy to a dose of 60-66 Gy showed a mean percentage flow of 20 percent and a significant fall in the pH of the saliva produced. Six glands that had received CHART (Continuous Hyperfractionated Accelerated RadioTherapy) and 8 conventionally fractionated radiotherapy to a dose of 35-40 Gy showed mean percentage flows of 57 and 65 percent respectively, with only slight and non-significant falls in saliva pH. The results show that in the treatment of squamous cell carcinoma in the head and neck the use of CHART can lead to considerable less late change in the function of the parotid gland. (author). 26 refs.; 5 figs.; 2 tabs

  15. SU-F-T-85: Energy Modulated Electron Postmastectomy Unreconstructed (PU) Chest Wall (CW) Irradiation Technique to Achieve Heart Sparing

    Energy Technology Data Exchange (ETDEWEB)

    Hong, L; Ballangrud, A; Mechalakos, J [Memorial Sloan-Kettering Cancer Center, New York, NY (United States); McCormick, B [Memerial Sloan-Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: For left-sided PU patients requiring CW and nodal irradiation, sometimes partial wide tangents (PWT) are not feasible due to abnormal chest wall contour or heart position close to the anterior chest wall or unusual wide excision scar. We developed an energy modulated electron chest wall irradiation technique that will achieve heart sparing. Methods: Ten left-sided PU patients were selected for this dosimetry study. If PWT were used, the amount of the ipsilateral lung would be ranged 3.4 to 4.4 cm, and the amount of heart would be ranged 1.3 to 3.8 cm. We used electron paired fields that matched on the skin to achieve dose conformity to the chest wall. The enface electron fields were designed at extended SSD from a single isocenter and gantry angle with different energy beams using different cutout. Lower energy was used in the central chest wall part and higher energy was used in the periphery of the chest wall. Bolus was used for the electron fields to ensure adequate skin dose coverage. The electron fields were matched to the photon supra-clavicle field in the superior region. Daily field junctions were used to feather the match lines between all the fields. Target volumes and normal tissues were drawn according to institutional protocols. Prescription dose was 2Gy per fraction for a total 50Gy. Dose calculations were done with Eclipse EMC-11031 for Electron and AAA-11031 for photons. Results: Six patients were planned using 6/9MeV, three using 9/12MeV and one 6/12MeV. Target volumes achieved adequate coverage. For heart, V30Gy, V20Gy and Mean Dose were 0.6%±0.6%, 2.7%±1.7%, and 3.0Gy±0.8Gy respectively. For ipsilateral lung, V50Gy, V20Gy, V10Gy and V5Gy were 0.9%±1.1%, 34.3%±5.1%, 51.6%±6.3% and 64.1%±7.5% respectively. Conclusion: For left-sided PU patients with unusual anatomy, energy modulated electron CW irradiation technique can achieve heart sparing with acceptable lung dose.

  16. Intensity-Modulated Radiotherapy of Head and Neck Cancer Aiming to Reduce Dysphagia: Early Dose-Effect Relationships for the Swallowing Structures

    International Nuclear Information System (INIS)

    Feng, Felix Y.; Kim, Hyungjin M.; Lyden, Teresa H.; Haxer, Marc J.; Feng, Mary; Worden, Frank P.; Chepeha, Douglas B.; Eisbruch, Avraham

    2007-01-01

    Purpose: To present initial results of a clinical trial of intensity-modulated radiotherapy (IMRT) aiming to spare the swallowing structures whose dysfunction after chemoradiation is a likely cause of dysphagia and aspiration, without compromising target doses. Methods and Materials: This was a prospective, longitudinal study of 36 patients with Stage III-IV oropharyngeal (31) or nasopharyngeal (5) cancer. Definitive chemo-IMRT spared salivary glands and swallowing structures: pharyngeal constrictors (PC), glottic and supraglottic larynx (GSL), and esophagus. Lateral but not medial retropharyngeal nodes were considered at risk. Dysphagia endpoints included objective swallowing dysfunction (videofluoroscopy), and both patient-reported and observer-rated scores. Correlations between doses and changes in these endpoints from pre-therapy to 3 months after therapy were assessed. Results: Significant correlations were observed between videofluoroscopy-based aspirations and the mean doses to the PC and GSL, as well as the partial volumes of these structures receiving 50-65 Gy; the highest correlations were associated with doses to the superior PC (p = 0.005). All patients with aspirations received mean PC doses >60 Gy or PC V 65 >50%, and GSL V 50 >50%. Reduced laryngeal elevation and epiglottic inversion were correlated with mean PC and GSL doses (p 70 >50%. Worsening patient-reported liquid swallowing was correlated with mean PC (p = 0.05) and esophageal (p 0.02) doses. Only mean PC doses were correlated with worsening patient-reported solid swallowing (p = 0.04) and observer-rated swallowing scores (p = 0.04). Conclusions: These dose-volume-effect relationships provide initial IMRT optimization goals and motivate further efforts to reduce swallowing structures doses to reduce dysphagia and aspiration

  17. Pump-To-Signal Intensity Modulation Transfer Characteristics in FOPAs: Modulation Frequency and Saturation Effect

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Cristofori, Valentina; Lund-Hansen, Toke

    2012-01-01

    This paper reports a comprehensive study of pump- to-signal intensity modulation transfer (IMT) in single-pump fiber optic parametric amplifiers (FOPAs). In particular, the IMT is studied for the first time for high-frequency fluctuations of the pump as well as in the saturated gain regime. The IMT...... cut-off frequency in typical single-pump FOPAs is around 100–200 GHz. The possibilities to shift this frequency based on dispersion and nonlinearities involved in the parametric gain are discussed. The severe IMT to the signal at low modulation frequencies can be suppressed by more than 50...

  18. Mucoepidermoid carcinoma of parotid gland: A case report

    Directory of Open Access Journals (Sweden)

    Jeetendra Purohit

    2015-01-01

    Full Text Available Mucoepidermoid carcinoma (MEC is the most common malignant neoplasm of the major salivary glands, accounting for 15.5% of all cases, benign and malignant. The aim of this article is to report a case of MEC in a 73-years-old male patient who presented with a painless firm fluctuant swelling in left preauricular area. The lesion was thoroughly examined preoperatively, and investigations were carried out. Fine-needle aspiration cytology was done for the lesion and report suggested tumor of the parotid gland. Superficial parotidectomy procedure was done, taking care not to injure the lower division of the facial nerve. Post recovery was uneventful with no defect of facial nerve functions. The histologic picture confirmed that the tumor was MEC of parotid gland. Through the literature reviews of MEC the discussions on prevalence, origin, diagnosis, histological finding, investigation and the modes of treatment are made.

  19. An experimental study of the irradiation effects on rat parotid gland

    International Nuclear Information System (INIS)

    Lee, Kyu Chan; Lee, Sang Rae

    1986-01-01

    This study was designed to investigate the irradiation effects on the rat parotid gland, applied to the head and neck region. For this experiment, twenty-four rat, feeded under the even condition, were used as experimental animals. Twenty rat were used for experimental group and the rest were assigned to the control group. The experimental group was singly irradiated with 10 Gray through Cobalt-60 radiotherapy device, Pickre model 4M 60 (Field size; 12x5 cm, SSD; 50 cm, Depth; 1 cm). The experimental animals of both group were sacrificed each four animals in 2 days, 1 week, 2 weeks, 3 weeks and 4 weeks after irradiation. The specimens were examined through the light microscope using the H-E stain and H stain by routine procedure. The other specimens were observed under the fluorescence microscope using the B-O dichroic mirror and Y 45 5 barrier filter after PA-ACH stain. The results of this study were obtained as follows: 1. The parotid acini were severely degenerated and intraacinar space were widened. Within the acini, retained secretory granules and increased fibrosis were observed. Also the shape and the size of the acini showed very irregular atrophic degeneration. 2. The nuclei showed severe pyknosis, displacement and irregular aggregated appearance. 3. The tissue changes of the parotid acini were initiated after 2 days of irradiation and most severely appeared at the second week of irradiation, but almost returned to normal. 4. The salivary ducts of the parotid gland were severely atrophied, discontinued but initiated to regenerated after 3 weeks of irradiation.

  20. Salivary gland tumors of the parotid gland: CT and MR imaging findings with emphasis on intratumoral cystic components

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroki; Watanabe, Haruo [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Kanematsu, Masayuki [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Gifu University Hospital, High-Level Imaging Diagnosis Center, Gifu (Japan); Mizuta, Keisuke; Aoki, Mitsuhiro [Gifu University School of Medicine, Department of Otolaryngology, Gifu (Japan)

    2014-09-15

    The purpose of this study was to assess computed tomography (CT) and magnetic resonance (MR) imaging findings of salivary gland tumors of the parotid gland with emphasis on intratumoral cystic components. Seventy-two histopathologically confirmed salivary gland tumors of the parotid gland (44 benign and 28 malignant), which underwent both CT and MR imaging including contrast-enhanced study, were included in this study. We retrospectively reviewed images for the presence, number, occupying rate, margin characteristics, distribution, and predominant MR signal intensity of intratumoral cystic components. The prevalence of cystic components was greater in malignant than benign tumors (79 vs. 50 %, p < 0.05). The number and occupying rate were similar between benign and malignant tumors. The irregular margins were more frequent in malignant than benign tumors (73 vs. 27 %, p < 0.01). The frequency of eccentric location was greater in benign than malignant tumors (91 vs. 55 %, p < 0.01), whereas the frequency of centric location was greater in malignant than benign tumors (32 vs. 0 %, p < 0.01). On T1-weighted images, the frequency of hyperintensity was greater in benign than malignant tumors (50 vs. 9 %, p < 0.01), whereas that of isointensity was greater in malignant than benign tumors (50 vs. 0 %, p < 0.01). Multiple logistic regression analysis showed that the absence of irregular margins of cystic components only was significantly correlated with the presence of benign salivary gland tumors (p < 0.01). Imaging features of intratumoral cystic components may help to differentiate benign from malignant tumors of the parotid salivary gland. (orig.)