WorldWideScience

Sample records for parallel-group single-dose two-center

  1. Safety and pharmacokinetics of single and multiple intravenous bolus doses of diclofenac sodium compared with oral diclofenac potassium 50 mg: A randomized, parallel-group, single-center study in healthy subjects.

    Science.gov (United States)

    Munjal, Sagar; Gautam, Anirudh; Okumu, Franklin; McDowell, James; Allenby, Kent

    2016-01-01

    In a randomized, parallel-group, single-center study in 42 healthy adults, the safety and pharmacokinetic parameters of an intravenous formulation of 18.75 and 37.5 mg diclofenac sodium (DFP-08) following single- and multiple-dose bolus administration were compared with diclofenac potassium 50 mg oral tablets. Mean AUC0-inf values for a 50-mg oral tablet and an 18.75-mg intravenous formulation were similar (1308.9 [393.0]) vs 1232.4 [147.6]). As measured by the AUC, DFP-08 18.75 mg and 37.5 mg demonstrated dose proportionality for extent of exposure. One subject in each of the placebo and DFP-08 18.75-mg groups and 2 subjects in the DFP-08 37.5-mg group reported adverse events that were considered by the investigator to be related to the study drug. All were mild in intensity and did not require treatment. Two subjects in the placebo group and 1 subject in the DFP-08 18.75-mg group reported grade 1 thrombophlebitis; no subjects reported higher than grade 1 thrombophlebitis after receiving a single intravenous dose. The 18.75- and 37.5-mg doses of intravenous diclofenac (single and multiple) were well tolerated for 7 days. Additional efficacy and safety studies are required to fully characterize the product. © 2015, The American College of Clinical Pharmacology.

  2. Pharmacokinetics of serelaxin in patients with hepatic impairment: a single-dose, open-label, parallel group study.

    Science.gov (United States)

    Kobalava, Zhanna; Villevalde, Svetlana; Kotovskaya, Yulia; Hinrichsen, Holger; Petersen-Sylla, Marc; Zaehringer, Andreas; Pang, Yinuo; Rajman, Iris; Canadi, Jasna; Dahlke, Marion; Lloyd, Peter; Halabi, Atef

    2015-06-01

    Serelaxin is a recombinant form of human relaxin-2 in development for treatment of acute heart failure. This study aimed to evaluate the pharmacokinetics (PK) of serelaxin in patients with hepatic impairment. Secondary objectives included evaluation of immunogenicity, safety and tolerability of serelaxin. This was an open-label, parallel group study (NCT01433458) comparing the PK of serelaxin following a single 24 h intravenous (i.v.) infusion (30 μg kg(-1)  day(-1) ) between patients with mild, moderate or severe hepatic impairment (Child-Pugh class A, B, C) and healthy matched controls. Blood sampling and standard safety assessments were conducted. Primary non-compartmental PK parameters [including area under the serum concentration-time curve AUC(0-48 h) and AUC(0-∞) and serum concentration at 24 h post-dose (C24h )] were compared between each hepatic impairment group and healthy controls. A total of 49 subjects (including 25 patients with hepatic impairment) were enrolled, of which 48 subjects completed the study. In all groups, the serum concentration of serelaxin increased over the first few hours of infusion, reached steady-state at 12-24 h and then declined following completion of infusion, with a mean terminal half-life of 7-8 h. All PK parameter estimates were comparable between each group of patients with hepatic impairment and healthy controls. No serious adverse events, discontinuations due to adverse events or deaths were reported. No serelaxin treatment-related antibodies developed during this study. The PK and safety profile of serelaxin were not affected by hepatic impairment. No dose adjustment is needed for serelaxin treatment of 48 h i.v. infusion in patients with hepatic impairment. © 2014 The British Pharmacological Society.

  3. A randomised, single-blind, single-dose, three-arm, parallel-group study in healthy subjects to demonstrate pharmacokinetic equivalence of ABP 501 and adalimumab.

    Science.gov (United States)

    Kaur, Primal; Chow, Vincent; Zhang, Nan; Moxness, Michael; Kaliyaperumal, Arunan; Markus, Richard

    2017-03-01

    To demonstrate pharmacokinetic (PK) similarity of biosimilar candidate ABP 501 relative to adalimumab reference product from the USA and European Union (EU) and evaluate safety, tolerability and immunogenicity of ABP 501. Randomised, single-blind, single-dose, three-arm, parallel-group study; healthy subjects were randomised to receive ABP 501 (n=67), adalimumab (USA) (n=69) or adalimumab (EU) (n=67) 40 mg subcutaneously. Primary end points were area under the serum concentration-time curve from time 0 extrapolated to infinity (AUC inf ) and the maximum observed concentration (C max ). Secondary end points included safety and immunogenicity. AUC inf and C max were similar across the three groups. Geometrical mean ratio (GMR) of AUC inf was 1.11 between ABP 501 and adalimumab (USA), and 1.04 between ABP 501 and adalimumab (EU). GMR of C max was 1.04 between ABP 501 and adalimumab (USA) and 0.96 between ABP 501 and adalimumab (EU). The 90% CIs for the GMRs of AUC inf and C max were within the prespecified standard PK equivalence criteria of 0.80 to 1.25. Treatment-related adverse events were mild to moderate and were reported for 35.8%, 24.6% and 41.8% of subjects in the ABP 501, adalimumab (USA) and adalimumab (EU) groups; incidence of antidrug antibodies (ADAbs) was similar among the study groups. Results of this study demonstrated PK similarity of ABP 501 with adalimumab (USA) and adalimumab (EU) after a single 40-mg subcutaneous injection. No new safety signals with ABP 501 were identified. The safety and tolerability of ABP 501 was similar to the reference products, and similar ADAb rates were observed across the three groups. EudraCT number 2012-000785-37; Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Oral sumatriptan for migraine in children and adolescents: a randomized, multicenter, placebo-controlled, parallel group study.

    Science.gov (United States)

    Fujita, Mitsue; Sato, Katsuaki; Nishioka, Hiroshi; Sakai, Fumihiko

    2014-04-01

    The objective of this article is to evaluate the efficacy and tolerability of two doses of oral sumatriptan vs placebo in the acute treatment of migraine in children and adolescents. Currently, there is no approved prescription medication in Japan for the treatment of migraine in children and adolescents. This was a multicenter, outpatient, single-attack, double-blind, randomized, placebo-controlled, parallel-group study. Eligible patients were children and adolescents aged 10 to 17 years diagnosed with migraine with or without aura (ICHD-II criteria 1.1 or 1.2) from 17 centers. They were randomized to receive sumatriptan 25 mg, 50 mg or placebo (1:1:2). The primary efficacy endpoint was headache relief by two grades on a five-grade scale at two hours post-dose. A total of 178 patients from 17 centers in Japan were enrolled and randomized to an investigational product in double-blind fashion. Of these, 144 patients self-treated a single migraine attack, and all provided a post-dose efficacy assessment and completed the study. The percentage of patients in the full analysis set (FAS) population who report pain relief at two hours post-treatment for the primary endpoint was higher in the placebo group than in the pooled sumatriptan group (38.6% vs 31.1%, 95% CI: -23.02 to 8.04, P  = 0.345). The percentage of patients in the FAS population who reported pain relief at four hours post-dose was higher in the pooled sumatriptan group (63.5%) than in the placebo group (51.4%) but failed to achieve statistical significance ( P  = 0.142). At four hours post-dose, percentages of patients who were pain free or had complete relief of photophobia or phonophobia were numerically higher in the sumatriptan pooled group compared to placebo. Both doses of oral sumatriptan were well tolerated. No adverse events (AEs) were serious or led to study withdrawal. The most common AEs were somnolence in 6% (two patients) in the sumatriptan 25 mg treatment group and chest

  5. Improved metabolic control in tetrahydrobiopterin (BH4), responsive phenylketonuria with sapropterin administered in two divided doses vs. a single daily dose.

    Science.gov (United States)

    Kör, Deniz; Yılmaz, Berna Şeker; Bulut, Fatma Derya; Ceylaner, Serdar; Mungan, Neslihan Önenli

    2017-07-26

    Phenylketonuria (PKU) often requires a lifelong phenylalanine (Phe)-restricted diet. Introduction of 6R-tetrahydrobiopterin (BH4) has made a huge difference in the diets of patients with PKU. BH4 is the co-factor of the enzyme phenylalanine hydroxylase (PAH) and improves PAH activity and, thus, Phe tolerance in the diet. A limited number of published studies suggest a pharmacodynamic profile of BH4 more suitable to be administered in divided daily doses. After a 72-h BH4 loading test, sapropterin was initiated in 50 responsive patients. This case-control study was conducted by administering the same daily dose of sapropterin in group 1 (n=24) as a customary single dose or in two divided doses in group 2 (n=26) over 1 year. Mean daily consumption of Phe increased significantly after the first year of BH4 treatment in group 2 compared to group 1 (p<0.05). At the end of the first year of treatment with BH4, another dramatic difference observed between the two groups was the ability to transition to a Phe-free diet. Eight patients from group 2 and two from group 1 could quit dietary restriction. When given in two divided daily doses, BH4 was more efficacious than a single daily dose in increasing daily Phe consumption, Phe tolerance and the ability to transition to a Phe-unrestricted diet at the end of the first year of treatment.

  6. The Influence of Hepatic and Renal Impairment on the Pharmacokinetics of a Treatment for Herpes Zoster, Amenamevir (ASP2151): Phase 1, Open-Label, Single-Dose, Parallel-Group Studies.

    Science.gov (United States)

    Kusawake, Tomohiro; Kowalski, Donna; Takada, Akitsugu; Kato, Kota; Katashima, Masataka; Keirns, James J; Lewand, Michaelene; Lasseter, Kenneth C; Marbury, Thomas C; Preston, Richard A

    2017-12-01

    Amenamevir (ASP2151) is a nonnucleoside human herpesvirus helicase-primase inhibitor that was approved in Japan for the treatment of herpes zoster (shingles) in 2017. This article reports the results of two clinical trials that investigated the effects of renal and hepatic impairment on the pharmacokinetics of amenamevir. These studies were phase 1, open-label, single-dose (oral 400 mg), parallel-group studies evaluating the pharmacokinetics, safety, and tolerability of amenamevir in healthy participants and participants with moderate hepatic impairment and mild, moderate, and severe renal impairment. In the hepatic impairment study, the pharmacokinetic profile of amenamevir in participants with moderate hepatic impairment was generally similar to that of participants with normal hepatic function. In the renal impairment study, the area under the amenamevir concentration versus time curve from the time of dosing up to the time of the last sample with extrapolation to infinity of the terminal phase was increased by 78.1% in participants with severe renal impairment. There was a positive relationship between creatinine clearance and oral and renal clearance for amenamevir in the renal impairment study. In both studies, amenamevir was safe and well tolerated. The findings of the hepatic impairment study indicate that no dosing adjustment is required in patients with moderate hepatic impairment. In the renal impairment study, systemic amenamevir exposure was increased by renal impairment. However, it is unlikely that renal impairment will have a significant effect on the safety of amenamevir given that in previous pharmacokinetic and safety studies in healthy individuals amenamevir was safe and well tolerated after a single dose (5-2400 mg, fasted condition) and repeated doses for 7 days (300 or 600 mg, fed condition), and the amount of amenamevir exposure in the renal impairment study was covered by those studies. These findings suggest that amenamevir does not

  7. Parallel solutions of the two-group neutron diffusion equations

    International Nuclear Information System (INIS)

    Zee, K.S.; Turinsky, P.J.

    1987-01-01

    Recent efforts to adapt various numerical solution algorithms to parallel computer architectures have addressed the possibility of substantially reducing the running time of few-group neutron diffusion calculations. The authors have developed an efficient iterative parallel algorithm and an associated computer code for the rapid solution of the finite difference method representation of the two-group neutron diffusion equations on the CRAY X/MP-48 supercomputer having multi-CPUs and vector pipelines. For realistic simulation of light water reactor cores, the code employees a macroscopic depletion model with trace capability for selected fission product transients and critical boron. In addition to this, moderator and fuel temperature feedback models are also incorporated into the code. The validity of the physics models used in the code were benchmarked against qualified codes and proved accurate. This work is an extension of previous work in that various feedback effects are accounted for in the system; the entire code is structured to accommodate extensive vectorization; and an additional parallelism by multitasking is achieved not only for the solution of the matrix equations associated with the inner iterations but also for the other segments of the code, e.g., outer iterations

  8. Pharmacokinetics and bioavailability of plant lignan 7-hydroxymatairesinol and effects on serum enterolactone and clinical symptoms in postmenopausal women: a single-blinded, parallel, dose-comparison study.

    Science.gov (United States)

    Udani, Jay K; Brown, Donald J; Tan, Maria Olivia C; Hardy, Mary

    2013-01-01

    7-Hydroxymaitairesinol (7-HMR) is a naturally occurring plant lignan found in whole grains and the Norway spruce (Piciea abies). The purpose of this study was to evaluate the bioavailability of a proprietary 7-HMR product (HMRlignan, Linnea SA, Locarno, Switzerland) through measurement of lignan metabolites and metabolic precursors. A single-blind, parallel, pharmacokinetic and dose-comparison study was conducted on 22 postmenopausal females not receiving hormone replacement therapy. Subjects were enrolled in either a 36 mg/d (low-dose) or 72 mg/d dose (high-dose) regimen for 8 weeks. Primary measured outcomes included plasma levels of 7-HMR and enterolactone (ENL), and single-dose pharmacokinetic analysis was performed on a subset of subjects in the low-dose group. Safety data and adverse event reports were collected as well as data on hot flash frequency and severity. Pharmacokinetic studies demonstrated 7-HMR C max = 757.08 ng/ml at 1 hour and ENL C max = 4.8 ng/ml at 24 hours. From baseline to week 8, plasma 7-HMR levels increased by 191% in the low-dose group (p < 0.01) and by 1238% in the high-dose group (p < 0.05). Plasma ENL levels consistently increased as much as 157% from baseline in the low-dose group and 137% in the high-dose group. Additionally, the mean number of weekly hot flashes decreased by 50%, from 28.0/week to 14.3/week (p < 0.05) in the high-dose group. No significant safety issues were identified in this study. The results demonstrate that HMRlignan is quickly absorbed into the plasma and is metabolized to ENL in healthy postmenopausal women. Clinically, the data demonstrate a statistically significant improvement in hot flash frequency. Doses up to 72 mg/d HMRlignan for 8 weeks were safe and well tolerated in this population.

  9. A Cohort Study of Preoperative Single Dose Versus Four Doses of Antibiotics for Patients With Non-Complicated Acute Appendicitis

    Directory of Open Access Journals (Sweden)

    Salah H. Al Janaby

    2017-02-01

    Full Text Available Objective: To Test the efficacy of single preoperative dose of Cefotaxime 1gm and Metronidazole 500mg in reducing the surgical site infections (SSIs after open appendectomy in patients with non-complicated appendicitis (NCA Place and Duration of Study: Al Hilla General Teaching Hospital, Babel Governorate-Iraq, from January 2013 to January 2014. Patients & Methods: 100 patients, who underwent appendectomy for NCA and fulfilled the selection criteria, were randomized into two groups. The patients in group A received a single dose of pre-operative antibiotics (Cefotaxime sodium and metronidazole, while the group B patients received three more dose of the same antibiotics postoperatively. Patients of both groups were followed-up for 30 days to assess the postoperative infective complications. Results: Group A had 48, while group B comprised of 52 patients. The groups were comparable in the baseline characteristics. Statistically, P value in rates of SSIs between both the groups was 0.9182. None of the patients developed intra-abdominal collection. Conclusion: Single dose of pre-operative antibiotics (Cefotaxime and metronidazole was sufficient in reducing the SSIs after appendectomy for NPA. Postoperative antibiotics did not add an appreciable clinical benefit in these patients. Key words: Preoperative antibiotics, Appendectomy, Surgical site infection, Non-complicated appendicitis Abbreviations: SSI: Surgical Site Infection, NCA: non-complicated appendicitis CDC Center of Disease Control.

  10. Radiotherapy for calcaneodynia. Results of a single center prospective randomized dose optimization trial

    Energy Technology Data Exchange (ETDEWEB)

    Ott, O.J.; Jeremias, C.; Gaipl, U.S.; Frey, B.; Schmidt, M.; Fietkau, R. [University Hospital Erlangen (Germany). Dept. of Radiation Oncology

    2013-04-15

    The aim of this work was to compare the efficacy of two different dose fractionation schedules for radiotherapy of patients with calcaneodynia. Between February 2006 and April 2010, 457 consecutive evaluable patients were recruited for this prospective randomized trial. All patients received radiotherapy using the orthovoltage technique. One radiotherapy series consisted of 6 single fractions/3 weeks. In case of insufficient remission of pain after 6 weeks a second radiation series was performed. Patients were randomly assigned to receive either single doses of 0.5 or 1.0 Gy. Endpoint was pain reduction. Pain was measured before, immediately after, and 6 weeks after radiotherapy using a visual analogue scale (VAS) and a comprehensive pain score (CPS). The overall response rate for all patients was 87 % directly after and 88 % 6 weeks after radiotherapy. The mean VAS values before, immediately after, and 6 weeks after treatment for the 0.5 and 1.0 Gy groups were 65.5 {+-} 22.1 and 64.0 {+-} 20.5 (p = 0.188), 34.8 {+-} 24.7 and 39.0 {+-} 26.3 (p = 0.122), and 25.1 {+-} 26.8 and 28.9 {+-} 26.8 (p = 0.156), respectively. The mean CPS before, immediately after, and 6 weeks after treatment was 10.1 {+-} 2.7 and 10.0 {+-} 3.0 (p = 0.783), 5.6 {+-} 3.7 and 6.0 {+-} 3.9 (p = 0.336), 4.0 {+-} 4.1 and 4.3 {+-} 3.6 (p = 0.257), respectively. No statistically significant differences between the two single dose trial arms for early (p = 0.216) and delayed response (p = 0.080) were found. Radiotherapy is an effective treatment option for the management of calcaneodynia. For radiation protection reasons, the dose for a radiotherapy series is recommended not to exceed 3-6 Gy. (orig.)

  11. A survey of doses to worker groups in the nuclear industry

    International Nuclear Information System (INIS)

    Khan, T.A.; Baum, J.W.

    1991-01-01

    The the US National Council on Radiation Protection and Measurements (NCRP) has suggested ''...as guidance for radiation programs that cumulative exposure not exceed the age of the individual in years x 10 mSv (years x 1 rem).'' The International Commission on Radiological Protection (ICRP) has recommended a dose limit of 10 rem averaged over 5 years. With these developments in mind, the US Nuclear Regulatory Commission (NRC) requested the ALARA Center of the Brookhaven National Laboratory to undertake two parallel studies. One study, which is still ongoing, is to examine the impact of the newly recommended dose limits on the nuclear industry as a whole; the other study was intended to assist in this larger project by looking more closely at the nuclear power industry. Preliminary data had indicated that the critical industry as far as the impact of new regulatory limits were concerned would be the nuclear power industry, because, it was conjectured, there existed a core of highly skilled workers in some groups which routinely get higher than average exposures. The objectives of the second study were to get a better understanding of the situation vis grave a vis the nuclear power industry, by identifying the high-dose worker groups, quantifying the annual and lifetime doses to these groups to see the extent of the problem if there was one, and finally to determine if there were any dose-reduction techniques which were particularly suited to reducing doses to these groups. In this presentation we describe some of the things learned during our work on the two projects. For more detailed information on the project on dose-reduction techniques for high-dose worker groups in the nuclear power industry, see NUREG/CR-5139. An industry/advisory committee has been set up which is in the process of evaluating the data from the larger project on the impact of new dose limits and will shortly produce its report. 7 refs., 5 figs., 6 tabs

  12. Efficient coupling of a single diamond color center to propagating plasmonic gap modes

    DEFF Research Database (Denmark)

    Kumar, Shailesh; Huck, Alexander; Andersen, Ulrik L

    2013-01-01

    We report on coupling of a single nitrogen-vacancy (NV) center in a nanodiamond to the propagating gap mode of two parallel placed chemically grown silver nanowires. The coupled NV-center nanowire system is made by manipulating nanodiamonds and nanowires with the tip of an atomic force microscope...

  13. Single-Dose Lignocaine-Based Blood Cardioplegia in Single Valve Replacement Patients

    Directory of Open Access Journals (Sweden)

    Jaydip Ramani

    Full Text Available Abstract OBJECTIVE: Myocardial protection is the most important in cardiac surgery. We compared our modified single-dose long-acting lignocaine-based blood cardioplegia with short-acting St Thomas 1 blood cardioplegia in patients undergoing single valve replacement. METHODS: A total of 110 patients who underwent single (aortic or mitral valve replacement surgery were enrolled. Patients were divided in two groups based on the cardioplegia solution used. In group 1 (56 patients, long-acting lignocaine based-blood cardioplegia solution was administered as a single dose while in group 2 (54 patients, standard St Thomas IB (short-acting blood-based cardioplegia solution was administered and repeated every 20 minutes. All the patients were compared for preoperative baseline parameters, intraoperative and all the postoperative parameters. RESULTS: We did not find any statistically significant difference in preoperative baseline parameters. Cardiopulmonary bypass time were 73.8±16.5 and 76.4±16.9 minutes (P=0.43 and cross clamp time were 58.9±10.3 and 66.3±11.2 minutes (P=0.23 in group 1 and group 2, respectively. Mean of maximum inotrope score was 6.3±2.52 and 6.1±2.13 (P=0.65 in group 1 and group 2, respectively. We also did not find any statistically significant difference in creatine-phosphokinase-MB (CPK-MB, Troponin-I levels, lactate level and cardiac functions postoperatively. CONCLUSION: This study proves the safety and efficacy of long-acting lignocaine-based single-dose blood cardioplegia compared to the standard short-acting multi-dose blood cardioplegia in patients requiring the single valve replacement. Further studies need to be undertaken to establish this non-inferiority in situations of complex cardiac procedures especially in compromised patients.

  14. Single-dose and steady-state pharmacokinetics of diltiazem administered in two different tablet formulations

    DEFF Research Database (Denmark)

    Christrup, Lona Louring; Bonde, J; Rasmussen, S N

    1992-01-01

    Single-dose and steady state pharmacokinetics of diltiazem administered in two different oral formulations were assessed with particular reference to rate and extent of absorption. Following single dose administration a significant difference in tmax was observed (2.9 +/- 1.9 and 6.8 +/- 2.6 hr r...

  15. Efficacy and speed of onset of pain relief of fast-dissolving paracetamol on postsurgical dental pain: two randomized, single-dose, double-blind, placebo-controlled clinical studies.

    Science.gov (United States)

    Yue, Yong; Collaku, Agron; Brown, Jean; Buchanan, William L; Reed, Kenneth; Cooper, Stephen A; Otto, James

    2013-09-01

    Paracetamol (APAP), also known as acetaminophen, is the most commonly used over-the-counter analgesic for the treatment of mild-to-moderate pain. However, the speed of onset of pain relief is limited mainly to the standard, immediate-release formulation. Efficacy and speed of onset of pain relief are critical in acute pain situations such as postsurgical dental pain, because reducing pain can improve clinical outcome and reduce the risk of transition from acute pain to more chronic pain. Efficacy and rapid onset also reduce the risk of excessive dosing with the analgesic. We sought to investigate the dose-response efficacy and speed of onset of pain relief of a fast-dissolving APAP formulation compared with lower doses of APAP and placebo in dental patients after impacted third molar extraction. Two single-center, single-dose, randomized, placebo-controlled, double-blind, double-dummy, parallel-group studies (Study I and Study II) were conducted to evaluate the efficacy and speed of onset of pain relief of different doses of a fast-dissolving APAP tablet (FD-APAP), standard APAP, and placebo in patients with postsurgical dental pain following third molar extraction. In Study I, a single dose of FD-APAP 1000 mg, FD-APAP 500 mg, or placebo was given to 300 patients; in Study II, a single dose of FD-APAP 1000 mg, standard APAP 650 mg, or placebo was given to 401 patients. All 701 patients from both studies were included in the analysis and safety assessment. FD-APAP 1000 mg demonstrated significantly greater effect compared with FD-APAP 500 mg, APAP 650 mg, and placebo for all efficacy measurements, including sum of pain relief and pain intensity difference, total pain relief, sum of pain intensity difference, pain intensity difference, and pain relief score during 6 hours after the dose. Onset of confirmed first perceptible relief in subjects treated with FD-APAP 1000 mg was 15 minutes, which was 32% and 25% significantly shorter than onset of pain relief of FD

  16. Benign painful shoulder syndrome. Initial results of a single-center prospective randomized radiotherapy dose-optimization trial

    International Nuclear Information System (INIS)

    Ott, O.J.; Hertel, S.; Gaipl, U.S.; Frey, B.; Schmidt, M.; Fietkau, R.

    2012-01-01

    Background and purpose: To compare the efficacy of two different dose-fractionation schedules for radiotherapy of patients with benign painful shoulder syndrome. Patients and methods: Between February 2006 and February 2010, 312 consecutive evaluable patients were recruited for this prospective randomized trial. All patients received radiotherapy with an orthovoltage technique. One radiotherapy course consisted of 6 single fractions in 3 weeks. In case of insufficient remission of pain after 6 weeks, a second radiation series was performed. Patients were randomly assigned to receive either single doses of 0.5 or 1.0 Gy. The endpoint was pain reduction. Pain was measured before, right after, and 6 weeks after radiotherapy using a visual analogue scale (VAS) and a comprehensive pain score (CPS). Results: The overall response rate for all patients was 83% directly after and 85% 6 weeks after radiotherapy. The mean VAS values before, directly after, and 6 weeks after treatment for the 0.5 and 1.0 Gy groups were 56.8 ± 23.7 and 53.2 ± 21.8 (p = 0.158), 38.2 ± 26.1 and 34.0 ± 24.5 (p = 0.189), and 33.0 ± 27.2 and 23.7 ± 22.7 (p = 0.044), respectively. The mean CPS before, directly after, and 6 weeks after treatment was 9.7 ± 3.0 and 9.5 ± 2.7 (p = 0.309), 6.1 ± 3.6 and 5.4 ± 3.6 (p = 0.096), 5.3 ± 3.7 and 4.1 ± 3.7 (p = 0.052), respectively. Despite a slight advantage in the VAS analysis for the 1.0 Gy group for delayed response, the CPS analysis revealed no statistically significant differences between the two single-dose trial arms for early (p = 0.652) and delayed response quality (p = 0.380). Conclusion: Radiotherapy is an effective treatment option for the management of benign painful shoulder syndrome. Concerning radiation protection, the dose for a radiotherapy series is recommended not to exceed 3-6 Gy. (orig.)

  17. SCELib3.0: The new revision of SCELib, the parallel computational library of molecular properties in the Single Center Approach

    Science.gov (United States)

    Sanna, N.; Baccarelli, I.; Morelli, G.

    2009-12-01

    ) the filtering code readgau, (ii) the main reading function setinp, (iii) the sphint code (including changes to the CalcMO code), (iv) the densty code, (v) the vst code; the classes of platforms supported now include two more architectures based on accelerated coprocessors (Nvidia GSeries GPGPU and ClearSpeed e720 (ClearSpeed version, experimental; initial preliminary porting of the sphint() function not for production runs - see the code documentation for additional detail). A single-precision representation for real numbers in the SCE mapping of the GTOs ( sphint code), has been implemented into the new code; the I h symmetry point group for the molecular systems has been added to those already allowed in the SCE procedure; the orientation of the molecular axis system for the Cs (planar) symmetry has been changed in accord with the standard orientation adopted by the latest version of the quantum chemistry code (Gaussian C03 [2]), which is used to generate the input multi-centre molecular wavefunctions ( z-axis perpendicular to the symmetry plane); the abelian subgroup for the Cs point group has been changed from C 1 to Cs; atomic basis functions including g-type GTOs can now be single-center-expanded. Restrictions: Depending on the molecular system under study and on the operating conditions the program may or may not fit into available RAM memory. In this case a feature of the program is to memory map a disk file in order to efficiently access the memory data through a disk device. The parallel GP-GPU implementation limits the number of CPU threads to the number of GPU cores present. Running time: The execution time strongly depends on the molecular target description and on the hardware/OS chosen, it is directly proportional to the ( r,θ,φ) grid size and to the number of angular basis functions used. Thus, from the program printout of the main arrays memory occupancy, the user can approximately derive the expected computer time needed for a given calculation

  18. Comparative assessment of efficacy of two different pretreatment single oral doses of betamethasone on inter-appointment and postoperative discomfort: An in vivo clinical evaluation.

    Science.gov (United States)

    Gyanani, Hitesh; Chhabra, Naveen; Parmar, Ghanshyam R

    2016-01-01

    Study aimed to evaluate the efficacy of two different pretreatment single oral doses of betamethasone on the incidence of inter-appointment flare up and postoperative discomfort. Fifty-four patients aged 18-59 years requiring endodontic treatment were selected and randomly assigned to three groups; single pretreatment oral dose of placebo or betamethasone in two different oral doses of 0.5 mg and 1 mg, respectively. Endodontic therapy was completed in two visits using triple antibiotic paste as intracanal medicament. Patients were given a questionnaire to record their pain at 1, 2, 3, and 7 days after treatment. In the second visit, obturation was done, and the patients were again instructed to record their pain scores after treatment and discharged. The verbal rating scale was used for recording the pain scores. Statistical analysis was done using ANOVA and the Friedman test. 0.5 mg betamethasone group showed least mean pain scores among all experimental groups; however, there was no statistically significant difference between any of the groups ( P > 0.05). Pretreatment single oral dose of betamethasone is an effective in managing endodontic flare-ups; however, the results were statistically insignificant.

  19. SCELib2: the new revision of SCELib, the parallel computational library of molecular properties in the single center approach

    Science.gov (United States)

    Sanna, N.; Morelli, G.

    2004-09-01

    In this paper we present the new version of the SCELib program (CPC Catalogue identifier ADMG) a full numerical implementation of the Single Center Expansion (SCE) method. The physics involved is that of producing the SCE description of molecular electronic densities, of molecular electrostatic potentials and of molecular perturbed potentials due to a point negative or positive charge. This new revision of the program has been optimized to run in serial as well as in parallel execution mode, to support a larger set of molecular symmetries and to permit the restart of long-lasting calculations. To measure the performance of this new release, a comparative study has been carried out on the most powerful computing architectures in serial and parallel runs. The results of the calculations reported in this paper refer to real cases medium to large molecular systems and they are reported in full details to benchmark at best the parallel architectures the new SCELib code will run on. Program summaryTitle of program: SCELib2 Catalogue identifier: ADGU Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADGU Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Reference to previous versions: Comput. Phys. Commun. 128 (2) (2000) 139 (CPC catalogue identifier: ADMG) Does the new version supersede the original program?: Yes Computer for which the program is designed and others on which it has been tested: HP ES45 and rx2600, SUN ES4500, IBM SP and any single CPU workstation based on Alpha, SPARC, POWER, Itanium2 and X86 processors Installations: CASPUR, local Operating systems under which the program has been tested: HP Tru64 V5.X, SUNOS V5.8, IBM AIX V5.X, Linux RedHat V8.0 Programming language used: C Memory required to execute with typical data: 10 Mwords. Up to 2000 Mwords depending on the molecular system and runtime parameters No. of bits in a word: 64 No. of processors used: 1 to 32 Has the code been vectorized or parallelized?: Yes

  20. Efficacy and Safety of Single and Double Doses of Ivermectin versus 7-Day High Dose Albendazole for Chronic Strongyloidiasis

    Science.gov (United States)

    Suputtamongkol, Yupin; Premasathian, Nalinee; Bhumimuang, Kid; Waywa, Duangdao; Nilganuwong, Surasak; Karuphong, Ekkapun; Anekthananon, Thanomsak; Wanachiwanawin, Darawan; Silpasakorn, Saowaluk

    2011-01-01

    Background Strongyloidiasis, caused by an intestinal helminth Strongyloides stercoralis, is common throughout the tropics. It remains an important health problem due to autoinfection, which may result in hyperinfection and disseminated infection in immunosuppressed patients, especially patients receiving chemotherapy or corticosteroid treatment. Ivermectin and albendazole are effective against strongyloidiasis. However, the efficacy and the most effective dosing regimen are to be determined. Methods A prospective, randomized, open study was conducted in which a 7-day course of oral albendazole 800 mg daily was compared with a single dose (200 microgram/kilogram body weight), or double doses, given 2 weeks apart, of ivermectin in Thai patients with chronic strongyloidiasis. Patients were followed-up with 2 weeks after initiation of treatment, then 1 month, 3 months, 6 months, 9 months, and 1 year after treatment. Combination of direct microscopic examination of fecal smear, formol-ether concentration method, and modified Koga agar plate culture were used to detect strongyloides larvae in two consecutive fecal samples in each follow-up visit. The primary endpoint was clearance of strongyloides larvae from feces after treatment and at one year follow-up. Results Ninety patients were included in the analysis (30, 31 and 29 patients in albendazole, single dose, and double doses ivermectin group, respectively). All except one patient in this study had at least one concomitant disease. Diabetes mellitus, systemic lupus erythrematosus, nephrotic syndrome, hematologic malignancy, solid tumor and human immunodeficiency virus infection were common concomitant diseases in these patients. The median (range) duration of follow-up were 19 (2–76) weeks in albendazole group, 39 (2–74) weeks in single dose ivermectin group, and 26 (2–74) weeks in double doses ivermectin group. Parasitological cure rate were 63.3%, 96.8% and 93.1% in albendazole, single dose oral ivermectin

  1. A qualitative single case study of parallel processes

    DEFF Research Database (Denmark)

    Jacobsen, Claus Haugaard

    2007-01-01

    Parallel process in psychotherapy and supervision is a phenomenon manifest in relationships and interactions, that originates in one setting and is reflected in another. This article presents an explorative single case study of parallel processes based on qualitative analyses of two successive...... randomly chosen psychotherapy sessions with a schizophrenic patient and the supervision session given in between. The author's analysis is verified by an independent examiner's analysis. Parallel processes are identified and described. Reflections on the dynamics of parallel processes and supervisory...

  2. A Novel Highly Bioavailable Curcumin Formulation Improves Symptoms and Diagnostic Indicators in Rheumatoid Arthritis Patients: A Randomized, Double-Blind, Placebo-Controlled, Two-Dose, Three-Arm, and Parallel-Group Study.

    Science.gov (United States)

    Amalraj, Augustine; Varma, Karthik; Jacob, Joby; Divya, Chandradhara; Kunnumakkara, Ajaikumar B; Stohs, Sidney J; Gopi, Sreeraj

    2017-10-01

    Rheumatoid arthritis (RA) is an autoimmune, chronic systemic inflammatory disorder. The long-term use of currently available drugs for the treatment of RA has many potential side effects. Natural phytonutrients may serve as alternative strategies for the safe and effective treatment of RA, and curcuminoids have been used in Ayurvedic medicine for the treatment of inflammatory conditions for centuries. In this study, a novel, highly bioavailable form of curcumin in a completely natural turmeric matrix was evaluated for its ability to improve the clinical symptoms of RA. A randomized, double-blind, placebo-controlled, three-arm, parallel-group study was conducted to evaluate the comparative efficacy of two different doses of curcumin with that of a placebo in active RA patients. Twelve patients in each group received placebo, 250 or 500 mg of the curcumin product twice daily for 90 days. The responses of the patients were assessed using the American College of Rheumatology (ACR) response, visual analog scale (VAS), C-reactive protein (CRP), Disease Activity Score 28 (DAS28), erythrocyte sedimentation rate (ESR), and rheumatoid factor (RF) values. RA patients who received the curcumin product at both low and high doses reported statistically significant changes in their clinical symptoms at the end of the study. These observations were confirmed by significant changes in ESR, CPR, and RF values in patients receiving the study product compared to baseline and placebo. The results indicate that this novel curcumin in a turmeric matrix acts as an analgesic and anti-inflammatory agent for the management of RA at a dose as low as 250 mg twice daily as evidenced by significant improvement in the ESR, CRP, VAS, RF, DAS28, and ACR responses compared to placebo. Both doses of the study product were well tolerated and without side effects.

  3. The dose of nafamostat mesilate during plasma exchange with continuous hemodiafiltration in the series-parallel circuit.

    Science.gov (United States)

    Nakae, Hajime; Igarashi, Toshiko; Tajimi, Kimitaka

    2006-06-01

    We studied nafamostat mesilate (NM) and interleukin (IL)-18 levels to determine whether the dose of NM is reduced during plasma exchange (PE) with continuous hemodiafiltration (CHDF) when the series-parallel circuit is used. The subjects of the current study included four patients with acute hepatic failure who underwent PE with CHDF. The four patients underwent a total 15 PE + CHDF procedures, and for each procedure, they were randomized to receive either a half-dose of NM or no NM in the CHDF circuit. Eight procedures were carried out with NM administration, and seven were carried out without NM administration. The dose of NM in the NM group was significantly higher than that in the non-NM group (P = 0.040). No significant differences were observed between the two groups in the inlet NM concentration, the outlet NM concentration, or the rate of IL-18 removal. No statistical correlation was observed between the IL-18 level and the NM dose, the inlet NM concentration, or the outlet NM concentration. There was no blood access difficulty such as catheter failure or clotting of the filter. Thus, it might be possible to carry out PE and CHDF with the series-parallel method without administration of NM in the CHDF circuit.

  4. Parallel Computing Characteristics of Two-Phase Thermal-Hydraulics code, CUPID

    International Nuclear Information System (INIS)

    Lee, Jae Ryong; Yoon, Han Young

    2013-01-01

    Parallelized CUPID code has proved to be able to reproduce multi-dimensional thermal hydraulic analysis by validating with various conceptual problems and experimental data. In this paper, the characteristics of the parallelized CUPID code were investigated. Both single- and two phase simulation are taken into account. Since the scalability of a parallel simulation is known to be better for fine mesh system, two types of mesh system are considered. In addition, the dependency of the preconditioner for matrix solver was also compared. The scalability for the single-phase flow is better than that for two-phase flow due to the less numbers of iterations for solving pressure matrix. The CUPID code was investigated the parallel performance in terms of scalability. The CUPID code was parallelized with domain decomposition method. The MPI library was adopted to communicate the information at the interface cells. As increasing the number of mesh, the scalability is improved. For a given mesh, single-phase flow simulation with diagonal preconditioner shows the best speedup. However, for the two-phase flow simulation, the ILU preconditioner is recommended since it reduces the overall simulation time

  5. Patient radiation dose in diagnostic and interventional procedures for intracranial aneurysms: Experience at a single center

    International Nuclear Information System (INIS)

    Chun, Chang Woo; Kim, Bum Soo; Lee, Cheol Hyoun; Ihn, Yon Kwon; Shin, Yong Sam

    2014-01-01

    To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms in a large sample size from a single center. We studied a sample of 439 diagnostic and 149 therapeutic procedures for intracranial aneurysms in 480 patients (331 females, 149 males; median age, 57 years; range, 21-88 years), which were performed in 2012 with a biplane unit. Parameters including fluoroscopic time, dose-area product (DAP), and total angiographic image frames were obtained and analyzed. Mean fluoroscopic time, total mean DAP, and total image frames were 12.6 minutes, 136.6 +/- 44.8 Gy-cm 2 , and 251 +/- 49 frames for diagnostic procedures, 52.9 minutes, 226.0 +/- 129.2 Gy-cm 2 , and 241 frames for therapeutic procedures, and 52.2 minutes, 334.5 +/- 184.6 Gy-cm 2 , and 408 frames for when both procedures were performed during the same session. The third quartiles for diagnostic reference levels (DRLs) were 14.0, 61.1, and 66.1 minutes for fluoroscopy time, 154.2, 272.8, and 393.8 Gy-cm 2 for DAP, and 272, 276, and 535 for numbers of image frames in diagnostic, therapeutic, and both procedures in the same session, respectively. The proportions of fluoroscopy in DAP for the procedures were 11.4%, 50.5%, and 36.1%, respectively, for the three groups. The mean DAP for each 3-dimensional rotational angiographic acquisition was 19.2 +/- 3.2 Gy-cm 2 . On average, rotational angiography was used 1.4 +/- 0.6 times/session (range, 1-4; n = 580). Radiation dose in our study as measured by DAP, fluoroscopy time and image frames did not differ significantly from other reported DRL studies for cerebral angiography, and DAP was lower with fewer angiographic image frames for embolization. A national registry of radiation-dose data is a necessary next step to refine the dose reference level.

  6. A double-blind, randomized, multiple-dose, parallel-group study to characterize the occurrence of diarrhea following two different dosing regimens of neratinib, an irreversible pan-ErbB receptor tyrosine kinase inhibitor.

    Science.gov (United States)

    Abbas, Richat; Hug, Bruce A; Leister, Cathie; Sonnichsen, Daryl

    2012-07-01

    Neratinib, a potent, low-molecular-weight, orally administered, irreversible, pan-ErbB receptor tyrosine kinase inhibitor has antitumor activity in ErbB2 + breast cancer. The objective of this study was to characterize the onset, severity, and duration of diarrhea after administration of neratinib 240 mg once daily (QD) and 120 mg twice daily (BID) for ≤14 days in healthy subjects. A randomized, double-blind, parallel-group, inpatient study was conducted in 50 subjects given oral neratinib either 240 mg QD or 120 mg BID with food for ≤14 days. The primary endpoint was the proportion of subjects with diarrhea of at least moderate severity (grade 2; 5-7 loose stools/day). In subjects with grade 2 diarrhea, fecal analytes were determined. Pharmacokinetic profiles were characterized for neratinib on Days 1 and 7. No severe (grade 3) diarrhea was reported. By Day 4, all subjects had grade 1 diarrhea. Grade 2 diarrhea occurred in 11/22 evaluable subjects (50 % [90 % confidence interval (CI): 28-72 %]) in the QD group and 17/23 evaluable subjects (74 % [90 % CI: 52-90 %]) in the BID group (P = 0.130). In fecal analyses, 18 % tested positive for hemoglobin and 46 % revealed fecal lactoferrin. Specimen pH was neutral to slightly alkaline. In pharmacokinetic analyses, Day 1 peak plasma concentration and Day 7 steady-state exposure were higher with the QD regimen than the BID regimen. In an exploratory analysis, ABCG2 genotype showed no correlation with severity or onset of diarrhea. Incidences and onsets of at least grade 1 and at least grade 2 diarrhea were not improved on BID dosing compared with QD dosing.

  7. Targeting the adventitia with intracoronary beta-radiation: comparison of two dose prescriptions and the role of centering coronary arteries

    International Nuclear Information System (INIS)

    Kaluza, Grzegorz L.; Jenkins, Todd P.; Mourtada, Firas A.; Ali, Nadir M.; Lee, David P.; Okura, Hiroyuki; Fitzgerald, Peter J.; Raizner, Albert E.

    2002-01-01

    Purpose: To compare by intravascular ultrasound (IVUS) the efficacy of delivering the prescribed dose to the adventitia between two commonly used dose prescriptions for intracoronary radiotherapy. Methods and Materials: In 59 human postangioplasty coronary vessels, one IVUS cross-section (1 mm thick) with the highest plaque burden was used for creating dose-volume histograms with different hypothetical positions of the source. Results: On average, prescription to 1 mm beyond lumen surface resulted in delivery of the prescribed dose (20 Gy ± 20%) to a higher fraction of adventitial volume than with the prescription to 2 mm from the source, with source placed in vessel center, lumen center, or in the IVUS catheter position. Source placement in the lumen center resulted in a low dose heterogeneity to the adventitia and the least dose heterogeneity to the intima. Conclusions: Prescription to 1 mm beyond lumen surface appeared more effective in delivering the prescribed dose to the adventitia than the American Association of Physicists in Medicine (AAPM) recommended prescription to 2 mm from the source center. Moreover, centering the source in the lumen provides the better balance of effective adventitial targeting and intimal dose homogeneity. Modification of the current AAPM recommendation for dose prescription for intracoronary radiotherapy should be considered

  8. Effect of Low-Dose (Single-Dose Magnesium Sulfate on Postoperative Analgesia in Hysterectomy Patients Receiving Balanced General Anesthesia

    Directory of Open Access Journals (Sweden)

    Arman Taheri

    2015-01-01

    Full Text Available Background and Aim. Aparallel, randomized, double blinded, placebo-controlled trial study was designed to assess the efficacy of single low dose of intravenous magnesium sulfate on post-total abdominal hysterectomy (TAH pain relief under balanced general anesthesia. Subject and Methods. Forty women undergoing TAH surgery were assigned to two magnesium sulfate (N=20 and normal saline (N=20 groups randomly. The magnesium group received magnesium sulfate 50 mg·kg−1 in 100 mL of normal saline solution i.v as single-dose, just 15 minutes before induction of anesthesia whereas patients in control group received 100 mL of 0.9% sodium chloride solution at the same time. The same balanced general anesthesia was induced for two groups. Pethidine consumption was recorded over 24 hours precisely as postoperative analgesic. Pain score was evaluated with Numeric Rating Scale (NRS at 0, 6, 12, and 24 hours after the surgeries. Results. Postoperative pain score was lower in magnesium group at 6, 12, and 24 hours after the operations significantly (P<0.05. Pethidine requirement was significantly lower in magnesium group throughout 24 hours after the surgeries (P=0.0001. Conclusion. Single dose of magnesium sulfate during balanced general anesthesia could be considered as effective and safe method to reduce postoperative pain and opioid consumption after TAH.

  9. Effects of food intake on the pharmacokinetics of diclofenac potassium soft gelatin capsules: a single-dose, randomized, two-way crossover study.

    Science.gov (United States)

    Scallion, Ralph; Moore, Keith A

    2009-10-01

    Diclofenac potassium liquid-filled soft gelatin capsule (DPSGC) is an investigational formulation that uses dispersing agents designed to facilitate rapid and consistent absorption of this NSAID. The aim of this study was to characterize the effects of food intake on the pharmacokinetic (PK) profile of oral DPSGC at doses of 25 and 50 mg. In this open-label, randomized, single-dose (2 distinct doses), 2-way crossover bioavailability study, healthy adult volunteers were randomly assigned to receive a single dose of DPSGC 25 or 50 mg after an overnight fast (fasted condition) or high-fat breakfast (fed condition) (period 1). After 7 days, the participants received the same dose under the opposite fed/fasted condition (period 2). Serial blood samples were obtained before and through 6 hours after study drug administration. Concentrations of diclofenac in plasma were determined using HPLC, and PK profiles were studied using ANCOVA. Adverse events (AEs) were monitored and recorded on each in-clinic day. Of 47 participants included in the study, 24 received the 25-mg dose of DPSGC and 23 received the 50-mg dose. The majority of participants were male (80.9%), and the mean age was 28.6 years. The mean (SD) AUC values for the fasted and fed states were 691 (195) and 680 (184) ng x h/mL, respectively, with the 25-mg dose, and 1521 (377) and 1416 (366) ng . h/mL, respectively, with the 50-mg dose, suggesting that the extent of absorption was similar with both dietary conditions at each dose. Food intake was associated with decreases in C(max) by nearly half in the 25-mg group (fasted vs fed, 1156 [482] vs 686 [411] ng/mL, respectively; P < 0.05) and the 50-mg group (2365 [1034] vs 1154 [592 ng/mL; P < 0.05) and delayed T(max) in the 25-mg group (0.49 [0.16] vs 1.02 [0.55] hours; P < 0.05) and 50-mg group (0.51 [0.19] vs 1.28 [0.71] hours; P < 0.05). Two mild AEs (nasal congestion and light-headedness) were reported in 2 participants who received 25 mg under fed conditions

  10. An experimental study of two-phase flow instability on two parallel channel with low steam quality

    International Nuclear Information System (INIS)

    Jiang Shengyao; Wu shaorong; Bo Jinhai; Yao Meisheng; Han Bing; Zhang Youjie

    1988-01-01

    An experimental result of two-phase flow instability on two parallel channel natural circulation with low steam quality is presented. The comparison of instability in the single channel and that in parallel channel is given. The effect of unequal inlet resistance coefficient and unequal power on the parallel channel instability is described and the behaviour of instability with equal exit steam quality in the two channel is investigated

  11. Massively Parallel Single-Molecule Manipulation Using Centrifugal Force

    Science.gov (United States)

    Wong, Wesley; Halvorsen, Ken

    2011-03-01

    Precise manipulation of single molecules has led to remarkable insights in physics, chemistry, biology, and medicine. However, two issues that have impeded the widespread adoption of these techniques are equipment cost and the laborious nature of making measurements one molecule at a time. To meet these challenges, we have developed an approach that enables massively parallel single- molecule force measurements using centrifugal force. This approach is realized in the centrifuge force microscope, an instrument in which objects in an orbiting sample are subjected to a calibration-free, macroscopically uniform force- field while their micro-to-nanoscopic motions are observed. We demonstrate high- throughput single-molecule force spectroscopy with this technique by performing thousands of rupture experiments in parallel, characterizing force-dependent unbinding kinetics of an antibody-antigen pair in minutes rather than days. Currently, we are taking steps to integrate high-resolution detection, fluorescence, temperature control and a greater dynamic range in force. With significant benefits in efficiency, cost, simplicity, and versatility, single-molecule centrifugation has the potential to expand single-molecule experimentation to a wider range of researchers and experimental systems.

  12. Doses to worker groups in the nuclear industry

    International Nuclear Information System (INIS)

    Khan, T.; Baum, J.W.

    1992-01-01

    This article presents some of the results of a study carried out at the Brookhaven National Laboratory's ALARA Center on doses to various worker groups in the U.S. nuclear industry. In this study, data from workers in the industry were divided into male and female groups; the average radiation dose of these tow groups and the correlation of dose with age are presented. The male and female workers were further considered in the various sectors of the industry, and correlations of dose with age for each sector were investigated. For male workers, a downward correlation with age was observed, while for women there appeared to be a slight upward correlation. Data form 13 PWR and 9 BWR plants shows that a small, but important, group of workers would be affected by the NCRP proposed constraint of workers' lifetime dose in rem being maintained less than their ages. Various techniques proposed by the plants to reduce dose to this critical group of workers are also presented

  13. Single-dose volume regulation algorithm for a gas-compensated intrathecal infusion pump.

    Science.gov (United States)

    Nam, Kyoung Won; Kim, Kwang Gi; Sung, Mun Hyun; Choi, Seong Wook; Kim, Dae Hyun; Jo, Yung Ho

    2011-01-01

    The internal pressures of medication reservoirs of gas-compensated intrathecal medication infusion pumps decrease when medication is discharged, and these discharge-induced pressure drops can decrease the volume of medication discharged. To prevent these reductions, the volumes discharged must be adjusted to maintain the required dosage levels. In this study, the authors developed an automatic control algorithm for an intrathecal infusion pump developed by the Korean National Cancer Center that regulates single-dose volumes. The proposed algorithm estimates the amount of medication remaining and adjusts control parameters automatically to maintain single-dose volumes at predetermined levels. Experimental results demonstrated that the proposed algorithm can regulate mean single-dose volumes with a variation of 98%. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  14. Large-scale parallel configuration interaction. II. Two- and four-component double-group general active space implementation with application to BiH

    DEFF Research Database (Denmark)

    Knecht, Stefan; Jensen, Hans Jørgen Aagaard; Fleig, Timo

    2010-01-01

    We present a parallel implementation of a large-scale relativistic double-group configuration interaction CIprogram. It is applicable with a large variety of two- and four-component Hamiltonians. The parallel algorithm is based on a distributed data model in combination with a static load balanci...

  15. A double blind parallel group placebo controlled comparison of sedative and mnesic effects of etifoxine and lorazepam in healthy subjects [corrected].

    Science.gov (United States)

    Micallef, J; Soubrouillard, C; Guet, F; Le Guern, M E; Alquier, C; Bruguerolle, B; Blin, O

    2001-06-01

    This paper describes the psychomotor and mnesic effects of single oral doses of etifoxine (50 and 100 mg) and lorazepam (2 mg) in healthy subjects. Forty-eight healthy subjects were included in this randomized double blind, placebo controlled parallel group study [corrected]. The effects of drugs were assessed by using a battery of subjective and objective tests that explored mood and vigilance (Visual Analog Scale), attention (Barrage test), psychomotor performance (Choice Reaction Time) and memory (digit span, immediate and delayed free recall of a word list). Whereas vigilance, psychomotor performance and free recall were significantly impaired by lorazepam, neither dosage of etifoxine (50 and 100 mg) produced such effects. These results suggest that 50 and 100 mg single dose of etifoxine do not induce amnesia and sedation as compared to lorazepam.

  16. Single-dose Rituximab Therapy for Refractory Idiopathic Membranous Nephropathy: A Single-center Experience

    OpenAIRE

    Katsuno, Takayuki; Ozaki, Takenori; Kim, Hangsoo; Kato, Noritoshi; Suzuki, Yasuhiro; Akiyama, Shinichi; Ishimoto, Takuji; Kosugi, Tomoki; Tsuboi, Naotake; Ito, Yasuhiko; Maruyama, Shoichi

    2017-01-01

    To date, a recognized treatment for refractory membranous nephropathy (MN) has not been established. Recently, several reports have indicated the efficacy of rituximab as a novel treatment option. However, only a few published accounts exist of rituximab therapy for idiopathic MN (IMN) in the Asian population. We present the cases of three IMN patients who were treated with single-dose rituximab after they showed no response to conventional therapies, including corticosteroids, cyclosporine, ...

  17. Assessment of dose to the critical group and the world population

    International Nuclear Information System (INIS)

    Coulon, R.

    1978-01-01

    This paper reviews the basic principles of radiation protection and analyses the exposure of the public through radioactive transfers. The evaluation of the dose to the ''critical group'' is described and an application of the philosophy is proposed. A parallel study is conducted in the case of the evaluation of the dose to the world population. (author)

  18. Use of a booster dose of capsular group C meningococcal glycoconjugate vaccine to demonstrate immunologic memory in children primed with one or two vaccine doses in infancy.

    Science.gov (United States)

    Pace, David; Khatami, Ameneh; Attard-Montalto, Simon; Voysey, Merryn; Finn, Adam; Faust, Saul N; Heath, Paul T; Borrow, Ray; Snape, Matthew D; Pollard, Andrew J

    2016-12-07

    Use of a polysaccharide vaccine challenge to demonstrate immunologic memory after priming with capsular group C meningococcal conjugate vaccines (MenCC) risks induction of immunologic hyporesponsiveness. For this reason, MenCC vaccines are now used as probes of immunologic memory, however, no studies have demonstrated their ability to distinguish primed from unprimed children. This study was part of a randomised controlled trial investigating the immunogenicity of a booster dose of the combined Haemophilus influenzae type b and MenC-tetanus toxoid vaccine (Hib-MenC-TT) in infants receiving reduced dose MenCC vaccine priming schedules (one MenC-CRM/MenC-TT or two MenC-CRM vaccine doses) compared with an unprimed group. Antibody kinetics were studied in a subset of 269 children by measuring changes in the MenC serum bactericidal antibody, using rabbit complement, (MenC rSBA) titres and MenC specific IgG memory B-cells before and at 6 and 28days following the 12month booster vaccination. At 6days after the 12monthMenCC vaccine, the rise in MenC rSBA titres and MenC specific IgG memory B-cells of the primed groups were significantly higher than the infant MenCC naïve group. Participants primed with one MenC-TT dose had the highest increase in MenC rSBA titres compared with all other groups. The MenC rSBA titres at the 28th compared with the 6th day after boosting was significantly higher in those primed with a single MenC-TT/MenC-CRM vaccine in infancy compared with those who were not primed or who were primed with two doses of the MenC-CRM vaccine. Immunologic memory can be demonstrated by a MenCC booster vaccination but is affected by the type and number of MenCC doses used for infant priming. The MenC rSBA responses can be used to demonstrate successful immunologic priming. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Protect Patients by Using Single- and Multi-Dose Vials Correctly

    Centers for Disease Control (CDC) Podcasts

    2014-07-10

    CDC’s One & Only Campaign urges healthcare providers to recognize the differences between single-dose and multi-dose vials, and to understand appropriate use of each container type.  Created: 7/10/2014 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 7/10/2014.

  20. Perioperative single high dose ATG-Fresenius S administration as induction immunosuppressive therapy in cadaveric renal transplantation--preliminary results.

    Science.gov (United States)

    Samsel, R; Chmura, A; Włodarczyk, Z; Wyzgał, J; Cieciura, T; Lagiewska, B; Pliszczyński, J; Korczak, G; Lazowski, T; Paczek, L; Wałaszewski, J; Lao, M; Rowiński, W

    1999-01-01

    Monoclonal and polyclonal antilymphocyte antibodies have been used successfully in organ transplantation as induction therapy and in the treatment of acute graft rejection. Used for induction the medication is generally given for the first 7-10 days. The aim of this study was to assess the safety and efficacy of single high dose (9 mg/kg) ATG Fresenius S given perioperatively, before revascularization, to kidney allograft recipients. During last twelve months seventy six, first cadaveric kidney adult recipients were included into the study in two centers (center A-64, center B-12). All patients received triple drug immunosuppression (Neoral, steroids and Cellcept which was replaced by azathioprine after 4 months), and were randomized to receive ATG or not. The follow-up period ranged from 1 month up to 1 year. The preliminary results are very promising, the rejection rate in bolus group was significantly lower than in control. No significant side effects or serious adverse events in both groups were observed.

  1. Pharmacokinetic Effects of Antidrug Antibodies Occurring in Healthy Subjects After a Single Dose of Intravenous Infliximab.

    Science.gov (United States)

    Ehrenpreis, Eli D

    2017-12-01

    Infliximab pharmacokinetic studies have been performed in patients receiving chronic infliximab therapy. In these patients, infliximab antidrug antibodies (ADAs) increase infliximab clearance and decrease serum levels and drug efficacy. This study analyzed the pharmacokinetic effect of infliximab ADAs in healthy subjects receiving a single dose of intravenous infliximab. Data were obtained from a single-blind, parallel-group, single-dose study of healthy subjects receiving 5 mg/kg of intravenous SB2 (infliximab biosimilar), EU-sourced Remicade (EU-IFX) or US-sourced Remicade (US-IFX). Serum infliximab was measured at 1, 2, 3, 6, 12, 24, 48, and 72 h and at 5, 7, 14, 21, 28, 42, 56, and 70 days after administration. ADAs were measured pre-dose and at 29 and 71 days. Data from the first ten subjects randomized to each treatment arm were utilized for this study. A two-compartment model of the serum infliximab vs. time curve was developed using nonlinear regression. At 10 weeks, 11 subjects (37%) developed ADAs. ADAs were detected in four subjects after SB2, one subject after EU-IFX, and six subjects after US-IFX infusion. Of these, neutralizing antibodies occurred in one subject after SB2, in no subjects after EU-IFX, and in three subjects after US-IFX infusion. Infliximab clearance was increased in subjects with ADAs vs. those without ADAs (12.89 ± 2.69 vs. 9.90 ± 1.74 ml/h; p ADAs (282.4 ± 56.4 vs. 343.3 ± 61.9 h; p ADAs are common in healthy subjects after a single intravenous dose of infliximab and result in faster infliximab clearance, shorter elimination time, and lower serum infliximab levels. These data confirm that ADAs are common with biologic therapy and significantly impact the efficacy of these drugs.

  2. Speed Sensorless vector control of parallel-connected three-phase two-motor single-inverter drive system

    DEFF Research Database (Denmark)

    Gunabalan, Ramachandiran; Sanjeevikumar, Padmanaban; Blaabjerg, Frede

    2016-01-01

    to noise and parameter uncertainty. The gain matrix is absent in the natural observer. The rotor speed is estimated from the load torque, stator current, and rotor flux. Under symmetrical load conditions, the difference in speed between two induction motors is reduced by considering the motor parameters......This paper presents the characteristic behavior of direct vector control of two induction motors with sensorless speed feedback having the same rating parameters, paralleled combination, and supplied from a single current-controlled pulse-width-modulated voltage-source inverter drive. Natural...... observer design technique is known for its simple construction, which estimates the speed and rotor fluxes. Load torque is estimated by load torque adaptation and the average rotor flux was maintained constant by rotor flux feedback control. The technique’s convergence rate is very fast and is robust...

  3. Improved long-term survival after intra-operative single high-dose ATG-Fresenius induction in renal transplantation: a single centre experience.

    Science.gov (United States)

    Kaden, Jürgen; May, Gottfried; Völp, Andreas; Wesslau, Claus

    2009-01-01

    In organ grafts donor-specific sensitization is initiated immediately after revascularization. Therefore, in 1990 we introduced the intra-operative single high-dose ATG-Fresenius (ATG-F) induction in addition to standard triple drug therapy (TDT) consisting of steroids, azathioprine and cyclosporin. A total of 778 first renal transplantations from deceased donors, performed between 1987 and 1998, were included in this evaluation. This retrospective analysis of clinic records and electronic databases presents data of all recipients of first kidney grafts who received two different ATG-F inductions (1(st) group: 9 mg/kg body weight as single high-dose intra-operatively, n=484; 2(nd) group: 3 mg/kg body weight on 7 or 8 consecutive days as multiple-dose starting also intra-operatively, n=78) and standard TDT alone (3(rd) group: TDT alone, n=216). The 10-year patient survival rates were 72.6+/-2.6% (TDT + ATG-F single high-dose), 79.5+/-5.1% (TDT + ATG-F multiple-dose) and 67.2+/-3.7%% (TDT alone; Kaplan-Meier estimates with standard errors; ATG-F vs TDT alone, p=0.001). The 10-year graft survival rates with censoring of patients that died with a functioning graft were 73.8+/-2.4%, 57.7+/-5.8% and 58.4+/-3.6% (Kaplan-Meier estimates with standard errors; 1(st) vs 2(nd )and 3(rd) group, respectively, p<0.001) and the 10-year graft survival rates with patient death counted as graft failure were 58.3+/-2.7%, 55.7+/-5.8% and 48.2+/-3.5% (Kaplan-Meier estimates with standard errors; ATG-F single high-dose vs TDT, p=0.023). In pre-sensitized recipients there were also significant differences in favour of ATG-F, more notably in the single high-dose ATG-F induction. A total of 69% of the patients in the two cohorts receiving ATG-F did not experience any transplant rejections compared to 56% in patients undergoing TDT alone (p=0.018). The incidence of infectious complications was comparable across all groups. According to evidence obtained from the routine documentation of 778

  4. Nano-optical observation of cascade switching in a parallel superconducting nanowire single photon detector

    International Nuclear Information System (INIS)

    Heath, Robert M.; Tanner, Michael G.; Casaburi, Alessandro; Hadfield, Robert H.; Webster, Mark G.; San Emeterio Alvarez, Lara; Jiang, Weitao; Barber, Zoe H.; Warburton, Richard J.

    2014-01-01

    The device physics of parallel-wire superconducting nanowire single photon detectors is based on a cascade process. Using nano-optical techniques and a parallel wire device with spatially separate pixels, we explicitly demonstrate the single- and multi-photon triggering regimes. We develop a model for describing efficiency of a detector operating in the arm-trigger regime. We investigate the timing response of the detector when illuminating a single pixel and two pixels. We see a change in the active area of the detector between the two regimes and find the two-pixel trigger regime to have a faster timing response than the one-pixel regime

  5. TU-AB-BRC-12: Optimized Parallel MonteCarlo Dose Calculations for Secondary MU Checks

    Energy Technology Data Exchange (ETDEWEB)

    French, S; Nazareth, D [Roswell Park Cancer Institute, Buffalo, NY (United States); Bellor, M [Lockheed Martin, Manassas, VA (United States)

    2016-06-15

    Purpose: Secondary MU checks are an important tool used during a physics review of a treatment plan. Commercial software packages offer varying degrees of theoretical dose calculation accuracy, depending on the modality involved. Dose calculations of VMAT plans are especially prone to error due to the large approximations involved. Monte Carlo (MC) methods are not commonly used due to their long run times. We investigated two methods to increase the computational efficiency of MC dose simulations with the BEAMnrc code. Distributed computing resources, along with optimized code compilation, will allow for accurate and efficient VMAT dose calculations. Methods: The BEAMnrc package was installed on a high performance computing cluster accessible to our clinic. MATLAB and PYTHON scripts were developed to convert a clinical VMAT DICOM plan into BEAMnrc input files. The BEAMnrc installation was optimized by running the VMAT simulations through profiling tools which indicated the behavior of the constituent routines in the code, e.g. the bremsstrahlung splitting routine, and the specified random number generator. This information aided in determining the most efficient compiling parallel configuration for the specific CPU’s available on our cluster, resulting in the fastest VMAT simulation times. Our method was evaluated with calculations involving 10{sup 8} – 10{sup 9} particle histories which are sufficient to verify patient dose using VMAT. Results: Parallelization allowed the calculation of patient dose on the order of 10 – 15 hours with 100 parallel jobs. Due to the compiler optimization process, further speed increases of 23% were achieved when compared with the open-source compiler BEAMnrc packages. Conclusion: Analysis of the BEAMnrc code allowed us to optimize the compiler configuration for VMAT dose calculations. In future work, the optimized MC code, in conjunction with the parallel processing capabilities of BEAMnrc, will be applied to provide accurate

  6. In vivo assessment of catheter positioning accuracy and prolonged irradiation time on liver tolerance dose after single-fraction 192Ir high-dose-rate brachytherapy

    Directory of Open Access Journals (Sweden)

    Kropf Siegfried

    2011-09-01

    Full Text Available Abstract Background To assess brachytherapy catheter positioning accuracy and to evaluate the effects of prolonged irradiation time on the tolerance dose of normal liver parenchyma following single-fraction irradiation with 192 Ir. Materials and methods Fifty patients with 76 malignant liver tumors treated by computed tomography (CT-guided high-dose-rate brachytherapy (HDR-BT were included in the study. The prescribed radiation dose was delivered by 1 - 11 catheters with exposure times in the range of 844 - 4432 seconds. Magnetic resonance imaging (MRI datasets for assessing irradiation effects on normal liver tissue, edema, and hepatocyte dysfunction, obtained 6 and 12 weeks after HDR-BT, were merged with 3D dosimetry data. The isodose of the treatment plan covering the same volume as the irradiation effect was taken as a surrogate for the liver tissue tolerance dose. Catheter positioning accuracy was assessed by calculating the shift between the 3D center coordinates of the irradiation effect volume and the tolerance dose volume for 38 irradiation effects in 30 patients induced by catheters implanted in nearly parallel arrangement. Effects of prolonged irradiation were assessed in areas where the irradiation effect volume and tolerance dose volume did not overlap (mismatch areas by using a catheter contribution index. This index was calculated for 48 irradiation effects induced by at least two catheters in 44 patients. Results Positioning accuracy of the brachytherapy catheters was 5-6 mm. The orthogonal and axial shifts between the center coordinates of the irradiation effect volume and the tolerance dose volume in relation to the direction vector of catheter implantation were highly correlated and in first approximation identically in the T1-w and T2-w MRI sequences (p = 0.003 and p p = 0.001 and p = 0.004, respectively. There was a significant shift of the irradiation effect towards the catheter entry site compared with the planned dose

  7. Parallel processing of dose calculation for external photon beam therapy

    International Nuclear Information System (INIS)

    Kunieda, Etsuo; Ando, Yutaka; Tsukamoto, Nobuhiro; Ito, Hisao; Kubo, Atsushi

    1994-01-01

    We implemented external photon beam dose calculation programs into a parallel processor system consisting of Transputers, 32-bit processors especially suitable for multi-processor configuration. Two network conformations, binary-tree and pipeline, were evaluated for rectangular and irregular field dose calculation algorithms. Although computation speed increased in proportion to the number of CPU, substantial overhead caused by inter-processor communication occurred when a smaller computation load was delivered to each processor. On the other hand, for irregular field calculation, which requires more computation capability for each calculation point, the communication overhead was still less even when more than 50 processors were involved. Real-time responses could be expected for more complex algorithms by increasing the number of processors. (author)

  8. Activities of the ICRP task group on dose calculations (DOCAL)

    International Nuclear Information System (INIS)

    Bertelli, Luiz

    1997-01-01

    Full text. The International Commission of Radiological Protection has been doing many efforts to improve dose calculations due to intake of radionuclides by workers and members of the public. More specifically, the biokinetic models have become more and more physiologically based and developed for age-groups ranging from the embryo to the adult. The dosimetric aspects have also been very carefully revised and a new series of phantoms encompassing all developing stages of embryo and fetus were also envisaged. In order to assure the quality of the calculations, dose coefficients have been derived by two different laboratories and the results and methods have been frequently compared and discussed. A CD-ROM has been prepared allowing the user to obtain dose coefficients for the several age-groups for ingestion and inhalation of all important radionuclides. Inhalation dose coefficients will be available for several AMADs. For the particular case of embryo and fetus, doses will be calculated when the intake occurred before and during gestation for single and chronic patterns of intake

  9. A phase 2a randomized, parallel group, dose-ranging study of molindone in children with attention-deficit/hyperactivity disorder and persistent, serious conduct problems.

    Science.gov (United States)

    Stocks, Jennifer Dugan; Taneja, Baldeo K; Baroldi, Paolo; Findling, Robert L

    2012-04-01

    To evaluate safety and tolerability of four doses of immediate-release molindone hydrochloride in children with attention-deficit/hyperactivity disorder (ADHD) and serious conduct problems. This open-label, parallel-group, dose-ranging, multicenter trial randomized children, aged 6-12 years, with ADHD and persistent, serious conduct problems to receive oral molindone thrice daily for 9-12 weeks in four treatment groups: Group 1-10 mg (5 mg if weight conduct problems. Secondary outcome measures included change in Nisonger Child Behavior Rating Form-Typical Intelligence Quotient (NCBRF-TIQ) Conduct Problem subscale scores, change in Clinical Global Impressions-Severity (CGI-S) and -Improvement (CGI-I) subscale scores from baseline to end point, and Swanson, Nolan, and Pelham rating scale-revised (SNAP-IV) ADHD-related subscale scores. The study randomized 78 children; 55 completed the study. Treatment with molindone was generally well tolerated, with no clinically meaningful changes in laboratory or physical examination findings. The most common treatment-related adverse events (AEs) included somnolence (n=9), weight increase (n=8), akathisia (n=4), sedation (n=4), and abdominal pain (n=4). Mean weight increased by 0.54 kg, and mean body mass index by 0.24 kg/m(2). The incidence of AEs and treatment-related AEs increased with increasing dose. NCBRF-TIQ subscale scores improved in all four treatment groups, with 34%, 34%, 32%, and 55% decreases from baseline in groups 1, 2, 3, and 4, respectively. CGI-S and SNAP-IV scores improved over time in all treatment groups, and CGI-I scores improved to the greatest degree in group 4. Molindone at doses of 5-20 mg/day (children weighing <30 kg) and 20-40 mg (≥ 30 kg) was well tolerated, and preliminary efficacy results suggest that molindone produces dose-related behavioral improvements over 9-12 weeks. Additional double-blind, placebo-controlled trials are needed to further investigate molindone in this pediatric population.

  10. A comparison of a single-dose and a seven-day treatment with Amoxicillin in asymptomatic bacteriuria in pregnancy

    Directory of Open Access Journals (Sweden)

    Niro Manesh S

    1994-05-01

    Full Text Available In this study, 1600 pregnant women who had referred to two prenatal clinics (Imam Khomeini and Mirza Kochek-Khan were investigated. Ninety cases of asymptomatic bacteriuria were observed; 77 of those cooperated with us until the end of our study. The subjects, who were within the 14-36 weeks of gestational age, were randomly divided into two groups: Group A received the medicine (Amoxicillin in a single-dose (3gr.; and, group B received it within seven days (1gr. TDS. The rate of recovery (65% in group A and 56.8% in group B, based on chi-squared test, showed no significant difference (P=0.747%. According to the results of this study, we can conclude that single-dose treatment has the same value as a seven-day treatment and the advantages such as decreased total dose, lower cost, and a better patient compliance.

  11. Probing the conductance superposition law in single-molecule circuits with parallel paths.

    Science.gov (United States)

    Vazquez, H; Skouta, R; Schneebeli, S; Kamenetska, M; Breslow, R; Venkataraman, L; Hybertsen, M S

    2012-10-01

    According to Kirchhoff's circuit laws, the net conductance of two parallel components in an electronic circuit is the sum of the individual conductances. However, when the circuit dimensions are comparable to the electronic phase coherence length, quantum interference effects play a critical role, as exemplified by the Aharonov-Bohm effect in metal rings. At the molecular scale, interference effects dramatically reduce the electron transfer rate through a meta-connected benzene ring when compared with a para-connected benzene ring. For longer conjugated and cross-conjugated molecules, destructive interference effects have been observed in the tunnelling conductance through molecular junctions. Here, we investigate the conductance superposition law for parallel components in single-molecule circuits, particularly the role of interference. We synthesize a series of molecular systems that contain either one backbone or two backbones in parallel, bonded together cofacially by a common linker on each end. Single-molecule conductance measurements and transport calculations based on density functional theory show that the conductance of a double-backbone molecular junction can be more than twice that of a single-backbone junction, providing clear evidence for constructive interference.

  12. Comparison of single-dose nalbuphine versus tramadol for postoperative pain management in children: a randomized, controlled trial.

    Science.gov (United States)

    Liaqat, Naeem; Dar, Sajid Hameed

    2017-04-01

    Acute postoperative pain control in children is an essential component of postoperative care, particularly in daycare procedures. Giving patients continuous narcotic analgesics can be risky; however, a single dose may be sufficient. This study used a prospective, randomized controlled design and was conducted at the Pediatric Surgery Unit, Services Hospital, Lahore. In total, 150 patients who underwent inguinal herniotomy (age range: 1-12 years) were randomly assigned to two groups: group A (nalbuphine) and group B (tramadol). Patients were given a single dose of either nalbuphine (0.2 mg/kg) or tramadol (2 mg/kg) immediately after surgery and pain was measured at 0, 1, 2, 4, and 8 h. The demographic characteristics were similar between the two groups. The mean pain score was lower in group A than in group B at 0 and 1 h (P pain scores in group A were still lower, but not significantly. In all, 9 patients (12.0%) required rescue analgesics in group A compared to 16 patients (21.3%) in group B (P = 0.051). The mean time for requirement of rescue analgesics was 6.5 ± 0.5 h in group A and 5.3 ± 1.7 h in group B (P = 0.06). A single dose of nalbuphine is sufficient, and superior to tramadol, for postoperative pain management in children who have undergone daycare procedures.

  13. Comparison of the pharmacokinetics of a new 30 mg modified-release tablet formulation of metoclopramide for once-a-day administration versus 10 mg immediate-release tablets: a single and multiple-dose, randomized, open-label, parallel study in healthy male subjects.

    Science.gov (United States)

    Bernardo-Escudero, Roberto; Alonso-Campero, Rosalba; Francisco-Doce, María Teresa de Jesús; Cortés-Fuentes, Myriam; Villa-Vargas, Miriam; Angeles-Uribe, Juan

    2012-12-01

    The study aimed to assess the pharmacokinetics of a new, modified-release metoclopramide tablet, and compare it to an immediate-release tablet. A single and multiple-dose, randomized, open-label, parallel, pharmacokinetic study was conducted. Investigational products were administered to 26 healthy Hispanic Mexican male volunteers for two consecutive days: either one 30 mg modified-release tablet every 24 h, or one 10 mg immediate-release tablet every 8 h. Blood samples were collected after the first and last doses of metoclopramide. Plasma metoclopramide concentrations were determined by high-performance liquid chromatography. Safety and tolerability were assessed through vital signs measurements, clinical evaluations, and spontaneous reports from study subjects. All 26 subjects were included in the analyses [mean (SD) age: 27 (8) years, range 18-50; BMI: 23.65 (2.22) kg/m², range 18.01-27.47)]. Peak plasmatic concentrations were not statistically different with both formulations, but occurred significantly later (p 0.05)]. One adverse event was reported in the test group (diarrhea), and one in the reference group (headache). This study suggests that the 30 mg modified-release metoclopramide tablets show features compatible with slow-release formulations when compared to immediate-release tablets, and is suitable for once-a-day administration.

  14. Achievement of Therapeutic Goals with Low-Dose Imiglucerase in Gaucher Disease: A Single-Center Experience

    Directory of Open Access Journals (Sweden)

    Irina Tukan

    2013-01-01

    Full Text Available Gaucher disease, a lysosomal storage disorder, is a multisystem disorder with variable and unpredictable onset and severity. Disease-specific enzyme replacement therapy (ERT has been shown to reverse or ameliorate disease-specific hepatosplenomegaly and anemia and thrombocytopenia. ERT also impacts bone manifestations, including bone crises, bone pain, and appearance of new osteonecrosis, and improves bone mineral density to varying degrees. The objective of this study was to assess achievement of predefined therapeutic goals based on international registry outcomes for Israeli patients with Gaucher disease receiving imiglucerase for four consecutive years on a low-dose regimen followed in a single center. All data were taken from patient files. The therapeutic goals were taken from standards published in the literature for disease-specific clinical parameters. Among 164 patients at baseline, values for spleen and liver volumes, hemoglobin and platelet counts, and Z-scores for lumbar spine and femoral were significantly different from the goal. After four years ERT, there was a significant improvement ( in each of the therapeutic goal parameters from baseline. 15.2% of these patients achieved all hematology-visceral goals. In children, there was achievement of linear growth and puberty. This survey highlights the good overall response in symptomatic patients receiving low-dose ERT with imiglucerase in Israel.

  15. Single- and multiple-dose pharmacokinetics and absolute bioavailability of tedizolid.

    Science.gov (United States)

    Flanagan, Shawn; Fang, Edward; Muñoz, Kelly A; Minassian, Sonia L; Prokocimer, Philippe G

    2014-09-01

    Tedizolid phosphate is a novel antibacterial under investigation for the treatment of gram-positive infections. This study was conducted to assess the pharmacokinetics, safety, and tolerability of intravenous tedizolid phosphate as well as the oral bioavailability of tedizolid phosphate. Double-blind, single-ascending dose, multiple-dose pharmacokinetics study, as well as tolerability and open-label crossover studies. Single center in the United States (Covance Clinical Research Unit, Madison, WI) between September 2009 and January 2010. Ninety healthy volunteers. Single intravenous (IV) doses of tedizolid phosphate 50 mg (lead-in) and 100-400 mg. Single oral and IV dose of tedizolid phosphate 200 mg in crossover fashion. Multiple IV doses of tedizolid phosphate 200 and 300 mg for up to 7 days. A dose-dependent increase was observed in the maximum plasma concentration (1.2-5.1 μg/ml) and the area under the concentration-time curve (17.4-58.7 μg × hr/ml) of tedizolid (the microbiologically active moiety of tedizolid phosphate) after single IV doses of tedizolid phosphate 100-400 mg. Administration of IV tedizolid phosphate 200 mg once/day for 7 days resulted in minimal (28%) tedizolid accumulation. The absolute oral bioavailability of tedizolid after a single 200-mg dose of tedizolid phosphate was 91%; pharmacokinetic parameters of tedizolid were similar with oral and IV administration. Treatment-related adverse events occurred in 41% of subjects. Most adverse events were related to infusion site and became more frequent with multiple dosing. In an additional 3-day tolerability study, IV tedizolid phosphate 200 mg and placebo were similarly tolerated, based on visual infusion phlebitis scores. These results from a population of healthy volunteers support once/day dosing of tedizolid phosphate 200 mg with both the oral and IV formulations, without the need for dose adjustment when switching administration routes. © 2014 Cubist Pharmaceuticals. Pharmacotherapy

  16. High-dose 8% capsaicin patch in treatment of chemotherapy-induced peripheral neuropathy: single-center experience.

    Science.gov (United States)

    Filipczak-Bryniarska, Iwona; Krzyzewski, Roger M; Kucharz, Jakub; Michalowska-Kaczmarczyk, Anna; Kleja, Justyna; Woron, Jarosław; Strzepek, Katarzyna; Kazior, Lucyna; Wordliczek, Jerzy; Grodzicki, Tomasz; Krzemieniecki, Krzysztof

    2017-08-17

    High-dose capsaicin patch is effective in treatment of neuropathic pain in HIV-associated neuropathy and diabetic neuropathy. There are no studies assessing effectiveness of high-dose capsaicin patch in treatment of chemotherapy-induced peripheral neuropathy. We sought to determine the effectiveness of treatment of pain associated with chemotherapy-induced peripheral neuropathy with high-dose capsaicin patch. Our study group consisted of 18 patients with clinically confirmed oxaliplatin-induced neuropathy. Baseline characteristic including underling disease, received cumulative dose of neurotoxic agent, neuropathic symptoms, prior treatment and initial pain level were recorded. Pain was evaluated with Numeric Rating Scale prior to treatment with high-dose capsaicin and after 1.8 day and after 8 and 12 weeks after introducing treatment. Patients were divided into two groups accordingly to the amount of neurotoxic agent that caused neuropathy (high sensitivity and low sensitivity group). Most frequent symptoms of chemotherapy-induced neuropathy were: pain (88.89%), paresthesis (100%), sock and gloves sensation (100%) and hypoesthesis (100%). Initial pain level was 7.45 ± 1.14. Mean cumulative dose of oxaliplatin after which patients developed symptoms was 648.07 mg/m 2 . Mean pain level after 12 weeks of treatment was 0.20 ± 0.41. When examined according to high and low sensitivity to neurotoxic agent patients with low sensitivity had higher pain reduction, especially after 8 days after introducing treatment (69.55 ± 12.09 vs. 49.40 ± 20.34%; p = 0.02) and after 12 weeks (96.96 ± 5.56 vs. 83.93 ± 18.59%; p = 0.04). High-dose capsaicin patch is an effective treatment for pain associated with chemotherapy-induced neuropathy in patients treated with oxaliplatin. Patients with lower sensitivity to neurotoxic agents have better response to treatment and pain reduction.

  17. Radiation-induced heart disease due to intrathonacic tumor radiotherapy of a single dose to the rabbits' heart

    International Nuclear Information System (INIS)

    Zhou Weibing; Feng Yan; Chen Jiayi; Luo Quanyong

    2007-01-01

    Objective: To observe the changes of radiation-induced heart disease (RIHD) in the rabbits irradiated in clinical related dose, and to evaluate the apoptosis and hypoxia in the irradiated heart by the new scintigraphic agents of 99 Tc m -HL91 and 99 Tc m -Annexin V of heart SPECT. Methods: Tenty-four New Zealand white rabbits 4-month old and 2-3 kg by weight were divided into two groups. Group 1 (clinical related dose group): 16 irradiated by a single close from 0 to 18 Gy. Group 2 (high dose group): 8 irradiated dose from 22 to 80 Gy. The serum cTnI/CKMB, ECG, and heart SPECT(using 99 Tc m -MIBI, 99 Tc m -HL91 and 99 Tc m -Annexin V as agents) were detected before and after irradiation. The animals were followed for 5 months. Then biopsy of rabbit heart was performed and pathologic examination was made by H.E. stain. Results: In the 16 rabbits of clinical related dose group, none died of RIHD. Whereas 2 rabbits died of RIHD in the high dose group. One died of myocardial infarction and the other of congestive heart failure. According to the Stewart introduced heart lesion grading system, of the clinical close ann, there were moderate in 1 rabbit, minimal in 14; and of the high dose ann, it was severe in 2, marked in 1, moderate in 5. The parallel relation was observed between the ECG results and the pathological changes (χ 2 =0.08, P=0.771). Serum value of cTnI, was elevated at the 12th hour after irradiation reaching the peak and maintained for 4 months. However, it came down in the 5th month. The difference of serum cTnI value before and after radiation was statistically significant. Myocardial perfusion scintigraphy tested by heart SPECT ( 99 Tc m -MIBI) showed defects was present in all irradiated rabbits. The relationship between the defects and radiation dose or between the defects and the real RIHD was uncertain. The SPECT images displayed that 99 Tc m -HL91 and 99m Tc-Annexin V did not accumulate in the irradiated heart. Conclusions: No serious damage is

  18. Analysis of gamma irradiator dose rate using spent fuel elements with parallel configuration

    International Nuclear Information System (INIS)

    Setiyanto; Pudjijanto MS; Ardani

    2006-01-01

    To enhance the utilization of the RSG-GAS reactor spent fuel, the gamma irradiator using spent fuel elements as a gamma source is a suitable choice. This irradiator can be used for food sterilization and preservation. The first step before realization, it is necessary to determine the gamma dose rate theoretically. The assessment was realized for parallel configuration fuel elements with the irradiation space can be placed between fuel element series. This analysis of parallel model was choice to compare with the circle model and as long as possible to get more space for irradiation and to do manipulation of irradiation target. Dose rate calculation were done with MCNP, while the estimation of gamma activities of fuel element was realized by OREGEN code with 1 year of average delay time. The calculation result show that the gamma dose rate of parallel model decreased up to 50% relatively compared with the circle model, but the value still enough for sterilization and preservation. Especially for food preservation, this parallel model give more flexible, while the gamma dose rate can be adjusted to the irradiation needed. The conclusion of this assessment showed that the utilization of reactor spent fuels for gamma irradiator with parallel model give more advantage the circle model. (author)

  19. MO-C-17A-10: Comparison of Dose Deformable Accumulation by Using Parallel and Serial Approaches

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Z; Li, M; Wong, J [Morristown Medical Center, Morristown, NJ (United States)

    2014-06-15

    Purpose: The uncertainty of dose accumulation over multiple CT datasets with deformable fusion may have significant impact on clinical decisions. In this study, we investigate the difference of two dose summation approaches involving deformable fusion. Methods: Five patients, four external beam and one brachytherapy(BT), were chosen for the study. The BT patient was treated with CT-based HDR. The CT image sets acquired in the imageguidance process (8-11 CTs/patient) were used to determine the dose delivered to the four external beam patients. (prostate, pelvis, lung and head and neck). For the HDR patient (cervix), five CT image sets and the corresponding BT plans were used. In total 44 CT datasets and RT dose/plans were imported into the image fusion software MiM (6.0.4) for analysis.For each of the five clinical cases, the dose from each fraction was accumulated into the primary CT dataset by using both Parallel and Serial approaches. The dose-volume histogram (DVH) for CTV and selected organs-at-risks (OAR) were generated. The D95(CTV), OAR(mean) and OAR(max) for the four external beam cases the D90(CTV), and the max dose to bladder and rectum for the BT case were compared. Results: For the four external beam patients, the difference in D95(CTV) were <1.2% PD between the parallel and the serial approaches. The differences of the OAR(mean) and the OAR(max ) range from 0 to 3.7% and <1% PD respectively. For the HDR patient, the dose difference for D90 is 11% PD while that of the max dose to bladder and rectum were 11.5% and 23.3% respectively. Conclusion: For external beam treatments, the parallel and serial approaches have <5% difference probably because tumor volume and OAR have less changes from fraction to fraction. For the brachytherapy case, >10% dose difference between the two approaches was observed as significant volume changes of tumor and OAR were observed among treatment fractions.

  20. Parallel quantum computing in a single ensemble quantum computer

    International Nuclear Information System (INIS)

    Long Guilu; Xiao, L.

    2004-01-01

    We propose a parallel quantum computing mode for ensemble quantum computer. In this mode, some qubits are in pure states while other qubits are in mixed states. It enables a single ensemble quantum computer to perform 'single-instruction-multidata' type of parallel computation. Parallel quantum computing can provide additional speedup in Grover's algorithm and Shor's algorithm. In addition, it also makes a fuller use of qubit resources in an ensemble quantum computer. As a result, some qubits discarded in the preparation of an effective pure state in the Schulman-Varizani and the Cleve-DiVincenzo algorithms can be reutilized

  1. Single Dose Versus 3 Doses of Intramuscular Benzathine Penicillin for Early Syphilis in HIV: A Randomized Clinical Trial.

    Science.gov (United States)

    Andrade, Roberto; Rodriguez-Barradas, Maria C; Yasukawa, Kosuke; Villarreal, Erick; Ross, Michael; Serpa, Jose A

    2017-03-15

    Patients coinfected with syphilis and human immunodeficiency virus (HIV) may have a slower decrease in rapid plasma reagin (RPR) titers. Currently a single dose of 2.4 million units of intramuscular benzathine penicillin G (BPG) is recommended for the treatment of early syphilis. Some observational studies have suggested that this regimen may lead to high failure rates in coinfected patients. We conducted an open-label randomized clinical trial to compare the efficacy of single-dose and 3-dose regimens of BPG for the treatment of early syphilis in HIV-infected individuals. RPR titers were monitored every 3 months. Treatment success was defined as a decrease in RPR titers of ≥2 dilutions (4-fold) during a 12-month follow-up period. Sixty-four patients were included. In the intention-to-treat analysis, treatment success rates were 80% (28 of 35 subjects) and 93% (27 of 29 subjects) in the single-dose and 3-dose regimens, respectively (absolute difference, 13% [95% confidence interval {CI}, -5% to 30%; P = .17). In the per-protocol analysis, success rates were 93% (27 of 29) and 100% in the single-dose and 3-dose regimens, respectively (absolute difference, 7% [95% CI, -7% to 22%]; P = .49). CD4 T-cell count, RPR titer and syphilis stage did not affect treatment results. When compared with a single dose of BPG, a 3-dose regimen did not improve syphilis serological outcomes. Our results support the Centers for Disease Control and Prevention recommendation of a single dose of BPG in HIV-infected patients with early syphilis. NCT02611765. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  2. Efficacy of various single-dose regimens of ceftriaxone in ...

    African Journals Online (AJOL)

    The therapeutic efficacy of single intramuscular doses of ceftriaxone (Rocephin; Roche) (62,S, 125 and 250 mg), administered without probenecid, was evaluated in 167 adult males with uncomplicated acute gonococcal urethritis. Cure rates of 100% were achieved at 62,5 mg and 250 mg. In the 125 mg dose group, ...

  3. SINGLE-DOSE VERSUS 3-DAY PROPHYLAXIS WITH CIPROFLOXACIN IN TRANSURETHRAL SURGERY - A CLINICAL-TRIAL

    NARCIS (Netherlands)

    BIJL, W; JANKNEGT, RA

    1993-01-01

    in 235 patients who underwent transurethral surgery, perioperative oral ciprofloxacin prophylaxis was given as a single dose 500 mg versus a 3-day regimen. Out of 180 evaluable patients, 84 received a single dose and 96 received a 3-day course. In the single dose prophylaxis group there were 5

  4. Controlled single-blind clinical evaluation of low-dose mammographic screen: film systems

    International Nuclear Information System (INIS)

    Sickles, E.A.; Genant, H.K.

    1979-01-01

    The ability of five low-dose mammographic screen-film systems to portray normal and abnormal breast structures was evaluated in parallel with a study of physical image properties. Single-blind evaluations of the visibility of normal breast architecture, mass lesions, and calcifications were made on the mammograms of 100 patients radiographed with each of the systems. There was increased noise and slightly poorer resolution of the faster recording systems, but there was no difference in final diagnostic impressions among the five systems. These results suggest that the faster systems will result in substantial dose reduction without sacrificing diagnostic accuracy

  5. High-Dose-Rate Brachytherapy of a Single Implant With Two Fractions Combined With External Beam Radiotherapy for Hormone-Naive Prostate Cancer

    International Nuclear Information System (INIS)

    Sato, Morio; Mori, Takashi; Shirai, Shintaro; Kishi, Kazushi; Inagaki, Takeshi; Hara, Isao

    2008-01-01

    Purpose: To evaluate the preliminary outcomes of high-dose-rate (HDR) brachytherapy of a single implant with two fractions and external beam radiotherapy (EBRT) for hormone-naive prostate cancer. Methods and Materials: Between March 2000 and Sept 2003, a total of 53 patients with tumor Stage T1c-T3b N0 M0 prostate cancer were treated with HDR brachytherapy boost doses (7.5 Gy/fraction) and 50-Gy EBRT during a 5.5-week period. Median follow-up was 61 months. Patients were divided into groups with localized (T1c-T2b) and advanced disease (T3a-T3b). We used the American Society for Therapeutic Radiology and Oncology (ASTRO) definition for biochemical failure. According to recommendations of the Radiation Therapy Oncology Group-ASTRO Phoenix Consensus Conference, biochemical failure-free control rates (BF-FCRs) at 3 years were investigated as 2 years short of the median follow-up. Results: Between April 2000 and Sept 2007, Common Terminology Criteria for Adverse Events Version 2.0 late Grade 2 genitourinary and gastrointestinal toxicity rates were 0% and 3.8%, respectively. Erectile preservation was 25% at 5 years. Overall survival was 88.1% and cause-specific survival was 100%. At 3 years, ASTRO BF-FCRs of the localized and advanced groups were 100% and 42%, respectively (p = 0.001). Conclusions: The HDR brachytherapy of a single implant with two fractions plus EBRT is effective in treating patients with localized hormone-naive prostate cancer, with the least genitourinary and gastrointestinal toxicities; however, longer median BF-FCR follow-up is required to assess these findings

  6. Parallel single-cell analysis microfluidic platform

    NARCIS (Netherlands)

    van den Brink, Floris Teunis Gerardus; Gool, Elmar; Frimat, Jean-Philippe; Bomer, Johan G.; van den Berg, Albert; le Gac, Severine

    2011-01-01

    We report a PDMS microfluidic platform for parallel single-cell analysis (PaSCAl) as a powerful tool to decipher the heterogeneity found in cell populations. Cells are trapped individually in dedicated pockets, and thereafter, a number of invasive or non-invasive analysis schemes are performed.

  7. Parallel-Batch Scheduling with Two Models of Deterioration to Minimize the Makespan

    Directory of Open Access Journals (Sweden)

    Cuixia Miao

    2014-01-01

    Full Text Available We consider the bounded parallel-batch scheduling with two models of deterioration, in which the processing time of the first model is pj=aj+αt and of the second model is pj=a+αjt. The objective is to minimize the makespan. We present O(n log n time algorithms for the single-machine problems, respectively. And we propose fully polynomial time approximation schemes to solve the identical-parallel-machine problem and uniform-parallel-machine problem, respectively.

  8. Safety, tolerability, and pharmacokinetics of single oral doses of tofacitinib, a Janus kinase inhibitor, in healthy volunteers.

    Science.gov (United States)

    Krishnaswami, Sriram; Boy, Mary; Chow, Vincent; Chan, Gary

    2015-03-01

    Tofacitinib is an oral Janus kinase inhibitor. This randomized, double-blind, parallel-group, placebo-controlled study was the first evaluation of tofacitinib in humans. The objectives were to characterize the safety and tolerability, pharmacokinetics (PK), and pharmacodynamics of escalating single tofacitinib doses in healthy subjects. Tofacitinib (0.1, 0.3, 1, 3, 10, 30, 60, and 100 mg) or placebo was administered as oral powder for constitution. For each dose, 7-9 subjects were randomized to tofacitinib and 3-5 subjects to placebo. Ninety-five males and females (age range 19-45) completed the study. Forty-nine treatment-emergent all-causality adverse events (AEs) were observed; nausea and headache were the most frequently reported. Tofacitinib PK was characterized by rapid absorption (time to peak serum concentration [Tmax ] 0.5-1 hour), rapid elimination (mean terminal half-lives 2.3-3.1 hours), and dose-proportional systemic exposures (peak serum concentration [Cmax ] and area under the serum concentration-time curve from time zero to infinity [AUC0-∞ ]). No appreciable correlation was observed between tofacitinib dose and lymphocyte subset counts. Single-dose tofacitinib up to 100 mg in healthy subjects had a safety profile of mostly mild AEs, and no deaths, serious AEs, severe AEs or discontinuations due to AEs. © 2014, The American College of Clinical Pharmacology.

  9. Evaluation of sphingolipids in Wistar rats treated to prolonged and single oral doses of fumonisin b₁.

    Science.gov (United States)

    Direito, Glória M; Almeida, Adriana P; Aquino, Simone; dos Reis, Tatiana Alves; Pozzi, Claudia Rodrigues; Corrêa, Benedito

    2009-01-01

    The objective of the present study was to evaluate sphingolipid levels (sphingosine-So and sphinganine-Sa) and to compare the Sa/So ratio in liver, serum and urine of Wistar rats after prolonged administration (21 days) of fumonisin B(1) (FB(1)). In parallel, the kinetics of sphingolipid elimination in urine was studied in animals receiving a single dose of FB(1). Prolonged exposure to FB(1) caused an increase in Sa levels in urine, serum and liver. The most marked effect on sphingolipid biosynthesis was observed in animals treated with the highest dose of FB(1). Animals receiving a single dose of FB(1) presented variations in Sa and So levels and in the Sa/So ratio.

  10. Modelling and simulation of multiple single - phase induction motor in parallel connection

    Directory of Open Access Journals (Sweden)

    Sujitjorn, S.

    2006-11-01

    Full Text Available A mathematical model for parallel connected n-multiple single-phase induction motors in generalized state-space form is proposed in this paper. The motor group draws electric power from one inverter. The model is developed by the dq-frame theory and was tested against four loading scenarios in which satisfactory results were obtained.

  11. Dual-sided reading versus single-sided reading: comparison of image quality and radiation dose between the two computed radiography system

    International Nuclear Information System (INIS)

    Song Shaojuan; Qi Hengtao; Zhao Yongxia; Jiao Fanglian

    2007-01-01

    Objective: To assess and compare the difference in image quality and exposure dose between single-sided reading image plate (IP) and dual-sided reading IP. Methods: A contrast-detail phantom CDRAD 2.0 was exposed by single-sided and dual-sided reading IP with different mAs sets. The entrance surface doses were recorded for all images. Images were then presented to two radiologists on a high resolution monitor of diagnosis workstation. The image quality figure (IQF) was measured for each image. Statistical analysis was performed using Spearman's correlation test and Wilcoxon signed-rank test to compare the difference in image quality and exposure dose between single-sided IP and dual-sided reading IP. Results: With different tube current dosage of 5.6, 12.0, 20.0, 25.0, and 40.0 mAs, IQF values of single-sided reading IP were 47.95, 37.68, 34.31, 28.61, and 24.65, respectively, while those of dual- sided reading IP were 38.83, 29.81, 29.65, 25.16, and 21.43, respectively. The IQF difference between them showed statistical significance (P<0.05). Conclusion: Image quality of dual-sided reading IP has been proved to be far superior to that of single-sided reading IP, in particular for low contrast detail. The image quality of single-sided reading IP is similar to that of dual-sided reading IP only at high dose levels. The clinical application of dual-sided reading IP will reduce the exposure dose by about 25% compared with single-sided reading IP. (authors)

  12. Can a single dose of human papillomavirus (HPV) vaccine prevent cervical cancer? Early findings from an Indian study.

    Science.gov (United States)

    Sankaranarayanan, Rengaswamy; Joshi, Smita; Muwonge, Richard; Esmy, Pulikottil Okkuru; Basu, Partha; Prabhu, Priya; Bhatla, Neerja; Nene, Bhagwan M; Shaw, Janmesh; Poli, Usha Rani Reddy; Verma, Yogesh; Zomawia, Eric; Pimple, Sharmila; Tommasino, Massimo; Pawlita, Michael; Gheit, Tarik; Waterboer, Tim; Sehr, Peter; Pillai, Madhavan Radhakrishna

    2018-03-15

    Human papillomavirus (HPV) vaccination is a major strategy for preventing cervical and other ano-genital cancers. Worldwide HPV vaccination introduction and coverage will be facilitated if a single dose of vaccine is as effective as two or three doses or demonstrates significant protective effect compared to 'no vaccination'. In a multi-centre cluster randomized trial of two vs three doses of quadrivalent HPV vaccination (Gardasil™) in India, suspension of the vaccination due to events unrelated to the study led to per protocol and partial vaccination of unmarried 10-18 year old girls leading to four study groups, two by design and two by default. They were followed up for the primary outcomes of immunogenicity in terms of L1 genotype-specific binding antibody titres, neutralising antibody titres, and antibody avidity for the vaccine-targeted HPV types and HPV infections. Analysis was per actual number of vaccine doses received. This study is registered with ISRCTN, number ISRCTN98283094; and with ClinicalTrials.gov, number NCT00923702. Of the 17,729 vaccinated girls, 4348 (25%) received three doses on days 1, 60, 180 or later, 4979 (28%) received two doses on days 1 and 180 or later, 3452 (19%) received two doses on days 1 and 60, and 4950 (28%) received one dose. One dose recipients demonstrated a robust and sustained immune response against HPV 16 and 18, albeit inferior to that of 3- or 2-doses and the antibody levels were stable over a 4 year period. The frequencies of cumulative incident and persistent HPV 16 and 18 infections up to 7 years of follow-up were similar and uniformly low in all the vaccinated study groups; the frequency of HPV 16 and 18 infections were significantly higher in unvaccinated age-matched control women than among vaccine recipients. The frequency of vaccine non-targeted HPV types was similar in the vaccinated groups but higher in the unvaccinated control women. Our results indicate that a single dose of quadrivalent HPV

  13. Comparing calibration methods of electron beams using plane-parallel chambers with absorbed-dose to water based protocols

    International Nuclear Information System (INIS)

    Stewart, K.J.; Seuntjens, J.P.

    2002-01-01

    Recent absorbed-dose-based protocols allow for two methods of calibrating electron beams using plane-parallel chambers, one using the N D,w Co for a plane-parallel chamber, and the other relying on cross-calibration of the plane-parallel chamber in a high-energy electron beam against a cylindrical chamber which has an N D,w Co factor. The second method is recommended as it avoids problems associated with the P wall correction factors at 60 Co for plane-parallel chambers which are used in the determination of the beam quality conversion factors. In this article we investigate the consistency of these two methods for the PTW Roos, Scanditronics NACP02, and PTW Markus chambers. We processed our data using both the AAPM TG-51 and the IAEA TRS-398 protocols. Wall correction factors in 60 Co beams and absorbed-dose beam quality conversion factors for 20 MeV electrons were derived for these chambers by cross-calibration against a cylindrical ionization chamber. Systematic differences of up to 1.6% were found between our values of P wall and those from the Monte Carlo calculations underlying AAPM TG-51, and up to 0.6% when comparing with the IAEA TRS-398 protocol. The differences in P wall translate directly into differences in the beam quality conversion factors in the respective protocols. The relatively large spread in the experimental data of P wall , and consequently the absorbed-dose beam quality conversion factor, confirms the importance of the cross-calibration technique when using plane-parallel chambers for calibrating clinical electron beams. We confirmed that for well-guarded plane-parallel chambers, the fluence perturbation correction factor at d max is not significantly different from the value at d ref . For the PTW Markus chamber the variation in the latter factor is consistent with published fits relating it to average energy at depth

  14. Pharmacodynamics of alfaxalone after single-dose intramuscular administration in red-eared sliders (Trachemys scripta elegans): a comparison of two different doses at two different ambient temperatures.

    Science.gov (United States)

    Shepard, Molly K; Divers, Stephen; Braun, Christina; Hofmeister, Erik H

    2013-11-01

    This study compares the pharmacodynamics of two different doses of alfaxalone administered intramuscularly (IM) to red-eared sliders at two ambient temperatures. Prospective blinded crossover experimental study. Nine adult female sliders (Trachemys scripta elegans). Following a 2-week acclimation at 22-25 °C, nine sliders were randomly assigned to receive alfaxalone, 10 mg kg(-1) (W10), or 20 mg kg(-1) (W20) IM. Each turtle received each dose, with a minimum 7-day washout period. A blinded observer evaluated heart rate (HR), palpebral and corneal reflexes, muscle relaxation, handling, and response to toe pinch at the following points: pre-injection, and 5, 12, 20, 30, 45, 60, and 120 minutes post-injection. Turtles then acclimated to 18-20 °C for 63 days, and the experiment was repeated in this lower-temperature environment, with treatment groups C10 (alfaxalone 10 mg kg(-1)) and C20 (alfaxalone 20 mg kg(-1)) subjected to the same crossover design. C10 and C20 groups had significantly lower intraanesthetic HR than W10 or W20, respectively. C10 and W20 were significantly more relaxed and easier to handle than W10. No significant differences were observed in palpebral reflex, nor responsiveness to the toe pinch stimulus. None of the turtles lost corneal reflex. W20 and C20 had prolonged recoveries, compared to low-dose groups within the same temperature environment. Recovery was also longer at C20 and C10 compared to W10. Turtles given 10 mg kg(-1) were more relaxed and easier to handle in cold than warm conditions. Warm turtles were more relaxed and easier to handle when given 20 mg kg(-1) than those given 10 mg kg(-1). Cold conditions correlated with lower HR and longer recovery time for each dose category. The turtles had dose-dependent and inconsistent responses to alfaxalone. Lower ambient temperature augmented the behavioral effects of this drug. © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  15. The Impact of a One-Dose versus Two-Dose Oral Cholera Vaccine Regimen in Outbreak Settings: A Modeling Study

    Science.gov (United States)

    Azman, Andrew S.; Luquero, Francisco J.; Ciglenecki, Iza; Grais, Rebecca F.; Sack, David A.; Lessler, Justin

    2015-01-01

    Background In 2013, a stockpile of oral cholera vaccine (OCV) was created for use in outbreak response, but vaccine availability remains severely limited. Innovative strategies are needed to maximize the health impact and minimize the logistical barriers to using available vaccine. Here we ask under what conditions the use of one dose rather than the internationally licensed two-dose protocol may do both. Methods and Findings Using mathematical models we determined the minimum relative single-dose efficacy (MRSE) at which single-dose reactive campaigns are expected to be as or more effective than two-dose campaigns with the same amount of vaccine. Average one- and two-dose OCV effectiveness was estimated from published literature and compared to the MRSE. Results were applied to recent outbreaks in Haiti, Zimbabwe, and Guinea using stochastic simulations to illustrate the potential impact of one- and two-dose campaigns. At the start of an epidemic, a single dose must be 35%–56% as efficacious as two doses to avert the same number of cases with a fixed amount of vaccine (i.e., MRSE between 35% and 56%). This threshold decreases as vaccination is delayed. Short-term OCV effectiveness is estimated to be 77% (95% CI 57%–88%) for two doses and 44% (95% CI −27% to 76%) for one dose. This results in a one-dose relative efficacy estimate of 57% (interquartile range 13%–88%), which is above conservative MRSE estimates. Using our best estimates of one- and two-dose efficacy, we projected that a single-dose reactive campaign could have prevented 70,584 (95% prediction interval [PI] 55,943–86,205) cases in Zimbabwe, 78,317 (95% PI 57,435–100,150) in Port-au-Prince, Haiti, and 2,826 (95% PI 2,490–3,170) cases in Conakry, Guinea: 1.1 to 1.2 times as many as a two-dose campaign. While extensive sensitivity analyses were performed, our projections of cases averted in past epidemics are based on severely limited single-dose efficacy data and may not fully capture

  16. The Impact of a One-Dose versus Two-Dose Oral Cholera Vaccine Regimen in Outbreak Settings: A Modeling Study.

    Directory of Open Access Journals (Sweden)

    Andrew S Azman

    2015-08-01

    Full Text Available In 2013, a stockpile of oral cholera vaccine (OCV was created for use in outbreak response, but vaccine availability remains severely limited. Innovative strategies are needed to maximize the health impact and minimize the logistical barriers to using available vaccine. Here we ask under what conditions the use of one dose rather than the internationally licensed two-dose protocol may do both.Using mathematical models we determined the minimum relative single-dose efficacy (MRSE at which single-dose reactive campaigns are expected to be as or more effective than two-dose campaigns with the same amount of vaccine. Average one- and two-dose OCV effectiveness was estimated from published literature and compared to the MRSE. Results were applied to recent outbreaks in Haiti, Zimbabwe, and Guinea using stochastic simulations to illustrate the potential impact of one- and two-dose campaigns. At the start of an epidemic, a single dose must be 35%-56% as efficacious as two doses to avert the same number of cases with a fixed amount of vaccine (i.e., MRSE between 35% and 56%. This threshold decreases as vaccination is delayed. Short-term OCV effectiveness is estimated to be 77% (95% CI 57%-88% for two doses and 44% (95% CI -27% to 76% for one dose. This results in a one-dose relative efficacy estimate of 57% (interquartile range 13%-88%, which is above conservative MRSE estimates. Using our best estimates of one- and two-dose efficacy, we projected that a single-dose reactive campaign could have prevented 70,584 (95% prediction interval [PI] 55,943-86,205 cases in Zimbabwe, 78,317 (95% PI 57,435-100,150 in Port-au-Prince, Haiti, and 2,826 (95% PI 2,490-3,170 cases in Conakry, Guinea: 1.1 to 1.2 times as many as a two-dose campaign. While extensive sensitivity analyses were performed, our projections of cases averted in past epidemics are based on severely limited single-dose efficacy data and may not fully capture uncertainty due to imperfect

  17. Single dose (400 mg) versus 7 day (200 mg) daily dose itraconazole in the treatment of tinea versicolor: a randomized clinical trial.

    Science.gov (United States)

    Wahab, M A; Ali, M E; Rahman, M H; Chowdhury, S A; Monamie, N S; Sultana, N; Khondoker, L

    2010-01-01

    Tinea (pityriasis) versicolor is a superficial fungal infection and one of the most commonly found pigmentary disorders of skin caused by the yeast Malassezia. Multiple topical as well as systemic therapies are available for treatment. Systemic therapies are used for extensive disease, frequent relapse or where topical agents have failed. The aim that translates the rationale of the study was to compare the efficacy, safety, tolerability and cost effectiveness of single dose 400mg versus 7 day 200 mg daily dose of itraconazole in the treatment of tinea versicolor. A clinical study was done to compare the efficacy of single dose (400 mg) of itraconazole and 7 day 200 mg daily dose of itraconazole in the treatment of extensive tinea versicolor. Total 60 patients (aged 18-50 years) were selected for the study during the period of June 2007 to May 2008 in the department of Dermatology of three different hospitals in Bangladesh. Cases having with extensive involvement, diagnosed clinically and confirmed by wood's lamp and KOH microscopy were taken. Patients were randomly allocated into equal groups. Group A was given single dose 400 mg itraconazole and Group B was given 7 day 200 mg daily itraconazole. Fifty three (88%) male and 7(12%) female were included in the study. The mean age of group A was 32.37+/-9 years and in group B 33.23+/-8 years. The mean duration of the disease in group A was 2.63+/-2 months and 2.76+/-2 months in group B. In group A clinical responders was found cure 22(73.33%) and improvement 5(16.33%) and in group B it was found cure 24(79.99%) and improvement 4(13.33%). The measure at the End point (EP1) equals to 90% response and in-group B it was found cure 24 (79.99%) and improvement 4(13.33%). (Here the End point EP2) equals to 93.33%. The EP clinical analysis however shows 91.66% response. Both single dose and 7 day daily dose of itraconazole can be effective in the treatment of tinea versicolor with extensive involvement but single dose appears

  18. Configuration affects parallel stent grafting results.

    Science.gov (United States)

    Tanious, Adam; Wooster, Mathew; Armstrong, Paul A; Zwiebel, Bruce; Grundy, Shane; Back, Martin R; Shames, Murray L

    2018-05-01

    A number of adjunctive "off-the-shelf" procedures have been described to treat complex aortic diseases. Our goal was to evaluate parallel stent graft configurations and to determine an optimal formula for these procedures. This is a retrospective review of all patients at a single medical center treated with parallel stent grafts from January 2010 to September 2015. Outcomes were evaluated on the basis of parallel graft orientation, type, and main body device. Primary end points included parallel stent graft compromise and overall endovascular aneurysm repair (EVAR) compromise. There were 78 patients treated with a total of 144 parallel stents for a variety of pathologic processes. There was a significant correlation between main body oversizing and snorkel compromise (P = .0195) and overall procedural complication (P = .0019) but not with endoleak rates. Patients were organized into the following oversizing groups for further analysis: 0% to 10%, 10% to 20%, and >20%. Those oversized into the 0% to 10% group had the highest rate of overall EVAR complication (73%; P = .0003). There were no significant correlations between any one particular configuration and overall procedural complication. There was also no significant correlation between total number of parallel stents employed and overall complication. Composite EVAR configuration had no significant correlation with individual snorkel compromise, endoleak, or overall EVAR or procedural complication. The configuration most prone to individual snorkel compromise and overall EVAR complication was a four-stent configuration with two stents in an antegrade position and two stents in a retrograde position (60% complication rate). The configuration most prone to endoleak was one or two stents in retrograde position (33% endoleak rate), followed by three stents in an all-antegrade position (25%). There was a significant correlation between individual stent configuration and stent compromise (P = .0385), with 31

  19. Two Phase Flow Split Model for Parallel Channels | Iloeje | Nigerian ...

    African Journals Online (AJOL)

    The model and code are capable of handling single and two phase flows, steady states and transients, up to ten parallel flow paths, simple and complicated geometries, including the boilers of fossil steam generators and nuclear power plants. A test calculation has been made with a simplified three-channel system ...

  20. Reduced dose uncertainty in MRI-based polymer gel dosimetry using parallel RF transmission with multiple RF sources

    International Nuclear Information System (INIS)

    Sang-Young Kim; Jung-Hoon Lee; Jin-Young Jung; Do-Wan Lee; Seu-Ran Lee; Bo-Young Choe; Hyeon-Man Baek; Korea University of Science and Technology, Daejeon; Dae-Hyun Kim; Jung-Whan Min; Ji-Yeon Park

    2014-01-01

    In this work, we present the feasibility of using a parallel RF transmit with multiple RF sources imaging method (MultiTransmit imaging) in polymer gel dosimetry. Image quality and B 1 field homogeneity was statistically better in the MultiTransmit imaging method than in conventional single source RF transmission imaging method. In particular, the standard uncertainty of R 2 was lower on the MultiTransmit images than on the conventional images. Furthermore, the MultiTransmit measurement showed improved dose resolution. Improved image quality and B 1 homogeneity results in reduced dose uncertainty, thereby suggesting the feasibility of MultiTransmit MR imaging in gel dosimetry. (author)

  1. Low-dose ketoconazole-fluconazole combination versus fluconazole in single doses for the treatment of vaginal candidiasis

    Directory of Open Access Journals (Sweden)

    Jan Susilo

    2011-08-01

    Full Text Available Background: Vaginal candidiasis (VC is one of the most common fungal diseases. Candida albicans is the most common causative fungus and has been isolated from more than 80% of specimens obtained from women with VC. Ketoconazole is the first orally active antifungal, the dosage for VC is 200 mg twice daily for 5 days. Fluconazole is the newer oral antifungal, its dosage for VC is a single oral dose of 150 mg. Since fluconazole 150 mg is considerably expensive, a single dose of 100 mg ketoconazole and 40 mg fluconazole in combination has been tested for the treatment of VC. The results showed that from 11 women with confirmed VC, 1-2 weeks after drug administration, the mycological culture was negative in 8 women, positive in 1 woman, and 2 woman lost to follow-up. This promising result led to the present study with the objective to confirm the efficacy and safety of the above combination in a formal clinical trial.Methods: A total of 165 female patients, aged 18 years or older, with the diagnosis of VC from clinical symptoms (pruritus or burning or excessive discharge and positive microscopic smear (pseudohyphae and/or yeast cells were randomized to receive a single dose of either keto-fluco combination (n = 85 or fluconazole (n = 80, and returnedfor follow-up visit on day 8.Results: Among these patients, 39 patients had negative baseline culture, leaving 126 patients eligible for efficacy evaluation. The mycological eradication in the keto-fluco group was 74.5% (41 patients from a total of 55 patients with available mycological culture, while that in the fluconazole group was 70.2% (40 patients from 57 patients with available culture and this difference was not significant. The clinical favorable response (clinical cure and clinical improvement in the keto-fluco arm (n = 60 was 98.3%, while that in the fluconazole group (n = 66 was 100%. Adverse events were found in 5 patients, 3 patients in the keto-fluco group (3/85 = 3.5% and 2

  2. Single and Multiple Ascending-dose Studies of Oral Delafloxacin: Effects of Food, Sex, and Age.

    Science.gov (United States)

    Hoover, Randall; Hunt, Thomas; Benedict, Michael; Paulson, Susan K; Lawrence, Laura; Cammarata, Sue; Sun, Eugene

    2016-01-01

    The objective of this report is describe the results of 2 studies that examined the pharmacokinetic parameters, safety profile, and tolerability of single and multiple ascending doses of oral delafloxacin and the effects of food, sex, and age on oral delafloxacin pharmacokinetic parameters, safety profile, and tolerability. The first study contained 3 parts and used unformulated delafloxacin in a capsule. Part 1 was a randomized, double-blind, placebo-controlled, single (50, 100, 200, 400, 800, 1200, and 1600 mg) ascending-dose study of oral delafloxacin in healthy men. Part 2 was a single-dose crossover study in which 20 men received 250 mg delafloxacin with or without food. Part 2 also included a parallel group, double-blind, placebo-controlled study in 16 women and 16 elderly men and women who were randomized (3:1) to receive 250 mg delafloxacin or placebo. Part 3 was a randomized, double-blind, placebo-controlled, multiple (100, 200, 400, 800, 1200 mg once daily for 5 days) ascending-dose study of oral delafloxacin in healthy men. The second study was a single-dose, randomized, 3-period crossover study in which participants received 900 mg delafloxacin (2 × 450-mg tablets) under fasted conditions, with a high-fat meal, or fasted with a high-fat meal 2 hours after dosing. Serial blood samples were collected, and plasma pharmacokinetic parameters of delafloxacin were determined. Delafloxacin Cmax and AUC0-∞ increased with increasing oral dose over the dose range of 50 to 1600 mg. The increases in delafloxacin AUC0-∞ were dose proportional at doses of ≥200 mg. Steady state was reached by day 3 of dosing with minimal accumulation of delafloxacin. The Cmax of delafloxacin was decreased slightly in the presence of food. No sex difference in delafloxacin pharmacokinetic parameters was observed. In the elderly men and women, mean delafloxacin Cmax and AUC0-∞ were 35% higher than observed for young adults, which could be partially explained by a decrease in

  3. A randomized, double-blind, placebo-controlled, multiple-dose, parallel-group clinical trial to assess the effects of teduglutide on gastric emptying of liquids in healthy subjects.

    Science.gov (United States)

    Berg, Jolene Kay; Kim, Eric H; Li, Benjamin; Joelsson, Bo; Youssef, Nader N

    2014-02-12

    Teduglutide, a recombinant analog of human glucagon-like peptide (GLP)-2, is a novel therapy recently approved for the treatment of adult patients with short bowel syndrome who are dependent on parenteral support. Previous studies assessing the effect of GLP-2 on gastric emptying in humans have yielded inconsistent results, with some studies showing no effect and others documenting a GLP-2-dependent delay in gastric emptying. The primary objective of this study was to assess the effect of teduglutide on gastric emptying of liquids in healthy subjects, as measured by the pharmacokinetics of acetaminophen. This double-blind, parallel-group, single-center study enrolled and randomized 36 healthy subjects (22 men, 14 women) to receive subcutaneous doses of teduglutide 4 mg or placebo (2:1 ratio; 23:13) once daily on Days 1 through 10 in the morning. Gastric emptying of a mixed nutrient liquid meal was assessed by measuring acetaminophen levels predose and at 0.25, 0.5, 0.75, 1, 1.25, 1.5, 2, 3, 3.5, 4, 5, 6, 8, 10, 12, and 14 hours after administration of 1000 mg acetaminophen on Days 0 and 10. The primary study endpoint was a pharmacokinetic analysis of acetaminophen absorption in subjects receiving teduglutide or placebo. No significant differences in gastric emptying of liquids (acetaminophen area under the concentration [AUC] vs time curve from time 0 to the last measurable concentration, AUC extrapolated to infinity, maximum concentration [Cmax], and time to Cmax) were observed on Day 10 in subjects receiving teduglutide 4 mg versus subjects receiving placebo. There were no serious adverse events (AEs), deaths, or discontinuations due to an AE reported during the study. Teduglutide 4 mg/day for 10 days does not affect gastric emptying of liquids in healthy subjects as measured by acetaminophen pharmacokinetics. No unexpected safety signals were observed. This study was registered at ClinicalTrials.gov, identifier NCT01209351.

  4. Study on children patient dose in single-detector and multi-detector row helical computed tomography

    International Nuclear Information System (INIS)

    Lu Heqing; Zhu Guoying; Zhuo Weihai; Liu Haikuan; Guo Changyi

    2008-01-01

    Objective: To study and evaluate the radiation dose of children patient in single-detector and multi-detector row helical CT scan. Methods: The head and body CT dose index of 21 CT scanners were tested. Then the values of CTDI w , CTDI vol and DLP were calculated combining with the parameters of routine head and chest scan for children of 0-1 year old group, 5 years old group, 10 years old group and adults. The effective doses of children of every age group and adults in routine head and chest scan were subsequently estimated from effective dose per DLP by age and the calculated values of DLP. Results: CTDI per mAs is greater in the head than that in the body. In head routine scan, the effective doses of 0-1 year old group,5 years old group and 10 year old group were 2.2, 1.3 and 1.1 mSv, respectively. In chest routine scan, the effective doses of 0-1 year old group,5 years old group and 10 years old group were 5.3, 3.1 and 3.4 mSv, respectively. Effective doses to children per mAs are equally 1.8 times higher than corresponding values for adults. The CTDI vol , DLP and effective dose to children in head routine scan for MDCT were greater those that for single-detector CT and dual- detector CT. The CTDI vol , DLP and effective dose to children in chest routine scan for MDCT and dual-detector row CT were smaller than that for single-detector row CT. Conclusions: Children me more radiation risk in CT examination as compared with adults. So we should strictly abide by justification of children CT examination, and optimize the parameters of CT scan rationally in order to reduce the radiation dose to children patient as much as possible. (authors)

  5. Absorbed dose calibration factors for parallel-plate chambers in high energy photon beams

    International Nuclear Information System (INIS)

    McEwen, M.R.; Duane, S.; Thomas, R.A.S.

    2002-01-01

    An investigation was carried out into the performance of parallel-plate chambers in 60 Co and MV photon beams. The aim was to derive calibration factors, investigate chamber-to-chamber variability and provide much-needed information on the use of parallel-plate chambers in high-energy X-ray beams. A set of NE2561/NE2611 reference chambers, calibrated against the primary standard graphite calorimeter is used for the dissemination of absorbed dose to water. The parallel-plate chambers were calibrated by comparison with the NPL reference chambers in a water phantom. Two types of parallel-plate chamber were investigated - the NACP -02 and Roos and measurements were made at 60 C0 and 6 linac photon energies (6-19 MV). Calibration factors were derived together with polarity corrections. The standard uncertainty in the calibration of a chamber in terms of absorbed dose to water is estimated to be ±0.75%. The results of the polarity measurements were somewhat confusing. One would expect the correction to be small and previous measurements in electron beams have indicated that there is little variation between chambers of these types. However, some chambers gave unexpectedly large polarity corrections, up to 0.8%. By contrast the measured polarity correction for a NE2611 chamber was less than 0.13% at all energies. The reason for these large polarity corrections is not clear, but experimental error and linac variations have been ruled out. By combining the calibration data for the different chambers it was possible to obtain experimental k Q factors for the two chamber types. It would appear from the data that the variations between chambers of the same type are random and one can therefore define a generic curve for each chamber type. These are presented in Figure 1, together with equivalent data for two cylindrical chamber types - NE2561/NE2611 and NE2571. As can be seen, there is a clear difference between the curves for the cylindrical chambers and those for the

  6. Parallel neural pathways in higher visual centers of the Drosophila brain that mediate wavelength-specific behavior

    Directory of Open Access Journals (Sweden)

    Hideo eOtsuna

    2014-02-01

    Full Text Available Compared with connections between the retinae and primary visual centers, relatively less is known in both mammals and insects about the functional segregation of neural pathways connecting primary and higher centers of the visual processing cascade. Here, using the Drosophila visual system as a model, we demonstrate two levels of parallel computation in the pathways that connect primary visual centers of the optic lobe to computational circuits embedded within deeper centers in the central brain. We show that a seemingly simple achromatic behavior, namely phototaxis, is under the control of several independent pathways, each of which is responsible for navigation towards unique wavelengths. Silencing just one pathway is enough to disturb phototaxis towards one characteristic monochromatic source, whereas phototactic behavior towards white light is not affected. The response spectrum of each demonstrable pathway is different from that of individual photoreceptors, suggesting subtractive computations. A choice assay between two colors showed that these pathways are responsible for navigation towards, but not for the detection itself of, the monochromatic light. The present study provides novel insights about how visual information is separated and processed in parallel to achieve robust control of an innate behavior.

  7. Evaluation of Sphingolipids in Wistar Rats Treated to Prolonged and Single Oral Doses of Fumonisin B1

    Science.gov (United States)

    Direito, Glória M.; Almeida, Adriana P.; Aquino, Simone; dos Reis, Tatiana Alves; Pozzi, Claudia Rodrigues; Corrêa, Benedito

    2009-01-01

    The objective of the present study was to evaluate sphingolipid levels (sphingosine-So and sphinganine-Sa) and to compare the Sa/So ratio in liver, serum and urine of Wistar rats after prolonged administration (21 days) of fumonisin B1 (FB1). In parallel, the kinetics of sphingolipid elimination in urine was studied in animals receiving a single dose of FB1. Prolonged exposure to FB1 caused an increase in Sa levels in urine, serum and liver. The most marked effect on sphingolipid biosynthesis was observed in animals treated with the highest dose of FB1. Animals receiving a single dose of FB1 presented variations in Sa and So levels and in the Sa/So ratio. PMID:19333435

  8. Effects of Different Radiation Doses on the Bond Strengths of Two Different Adhesive Systems to Enamel and Dentin.

    Science.gov (United States)

    da Cunha, Sandra Ribeiro de Barros; Ramos, Pedro Augusto Minorin Mendes; Haddad, Cecília Maria Kalil; da Silva, João Luis Fernandes; Fregnani, Eduardo Rodrigues; Aranha, Ana Cecília Corrêa

    2016-01-01

    To evaluate the effects of three different radiation doses on the bond strengths of two different adhesive systems to enamel and dentin. Eighty human third molars were randomly divided into four groups (n = 20) according to the radiation dose (control/no radiation, 20 Gy, 40 Gy, and 70 Gy). The teeth were sagittally sectioned into three slices: one mesial and one distal section containing enamel and one middle section containing dentin. The sections were then placed in the enamel and dentin groups, which were further divided into two subgroups (n = 10) according to the adhesive used. Three restorations were performed in each tooth (one per section) using Adper Single Bond 2 (3M ESPE) or Universal Single Bond (3M ESPE) adhesive system and Filtek Z350 XT (3M ESPE) resin composite and subjected to the microshear bond test. Data were analyzed using a two-way ANOVA followed by Tukey's test. Failure modes were examined under a stereoscopic loupe. Radiotherapy did not affect the bond strengths of the adhesives to either enamel or dentin. In dentin, the Universal Single Bond adhesive system showed higher bond strength values when compared with the Adper Single Bond adhesive system. More adhesive failures were observed in the enamel for all radiation doses and adhesives. Radiotherapy did not influence the bond strength to enamel or dentin, irrespective of the adhesive or radiation dose used.

  9. Effective dose to staff from interventional procedures: Estimations from single and double dosimetry

    International Nuclear Information System (INIS)

    Kuipers, G.; Velders, X. L.

    2009-01-01

    The exposure of 11 physicians performing interventional procedures was measured by means of two personal dosemeters. One personal dosemeter was worn outside the lead apron and an additional under the lead apron. The study was set up in order to determine the added value of a dosemeter worn under the lead apron. With the doses measured, the effective doses of the physicians were estimated using an algorithm for single dosimetry and two algorithms for double dosimetry. The effective doses calculated with the single dosimetry algorithm ranged from 0.11 to 0.85 mSv in 4 weeks. With the double dosimetry algorithms, the effective doses ranged from 0.02 mSv to 0.47 mSv. The statistical analysis revealed no significant differences in the accuracy of the effective doses calculated with single or double dosimetry algorithms. It was concluded that the effective dose cannot be considered a more accurate estimate when two dosemeters are used instead of one. (authors)

  10. A parallel algorithm for the two-dimensional time fractional diffusion equation with implicit difference method.

    Science.gov (United States)

    Gong, Chunye; Bao, Weimin; Tang, Guojian; Jiang, Yuewen; Liu, Jie

    2014-01-01

    It is very time consuming to solve fractional differential equations. The computational complexity of two-dimensional fractional differential equation (2D-TFDE) with iterative implicit finite difference method is O(M(x)M(y)N(2)). In this paper, we present a parallel algorithm for 2D-TFDE and give an in-depth discussion about this algorithm. A task distribution model and data layout with virtual boundary are designed for this parallel algorithm. The experimental results show that the parallel algorithm compares well with the exact solution. The parallel algorithm on single Intel Xeon X5540 CPU runs 3.16-4.17 times faster than the serial algorithm on single CPU core. The parallel efficiency of 81 processes is up to 88.24% compared with 9 processes on a distributed memory cluster system. We do think that the parallel computing technology will become a very basic method for the computational intensive fractional applications in the near future.

  11. Patch test dose-response study: polysensitized individuals do not express lower elicitation thresholds than single/double-sensitized individuals

    DEFF Research Database (Denmark)

    Carlsen, B C; Fischer, Louise Arup; Sosted, H

    2009-01-01

    with nickel sulphate, methyldibromo glutaronitrile (MDBGN) and p-phenylenediamine (PPD) in dilution series. The ratio between the doses eliciting a response in 50% of patients in the two groups was used as the measure for relative sensitivity. RESULTS: The dose-response curves of the polysensitized group...... for MDBGN and PPD were shifted to the right, and for nickel sulphate shifted to the left, compared with the single/double-sensitized group. The relative sensitivity for each of the three allergens and a combined relative sensitivity for all three allergens were not significantly different when comparing...

  12. Single-dose and multiple-dose pharmacokinetics and dose proportionality of intravenous and intramuscular HPβCD-diclofenac (Dyloject) compared with other diclofenac formulations.

    Science.gov (United States)

    Mermelstein, Fred; Hamilton, Douglas A; Wright, Curtis; Lacouture, Peter G; Ramaiya, Atulkumar; Carr, Daniel B

    2013-10-01

    To evaluate single- and repeated-dose pharmacokinetics (PK) and dose proportionality of hydroxypropyl-β-cyclodextrin (HPβCD)-diclofenac compared with Voltarol after intravenous (IV) and intramuscular (IM) administration. Study 1: Single-dose randomized four-way crossover study. Study 2: Multiple-dose randomized three-way crossover study. Clinical research center. Healthy adult volunteers. Study 1: Subjects received HPβCD-diclofenac and Voltarol, IV and IM, with a 5-day washout between treatment periods. Study 2: Subjects received two doses of IV HPβCD-diclofenac and oral Cataflam once every 6 hours for four doses with a 48-hour washout period between treatment periods. Study 1: IV HPβCD-diclofenac had a higher peak plasma concentration (Cmax ) and earlier time to reach maximum plasma concentration (Tmax ), but equivalent plasma exposure (area under the curve from time zero to t [AUC0-t ]) to IV Voltarol. The geometric mean ratio of HPβCD-diclofenac (IV) to Voltarol (IV) for AUC0-t was 106.27%. The geometric mean ratio of HPβCD-diclofenac (IM) to Voltarol (IM) for AUC0-t was 110.91%. The geometric mean ratio of HPβCD-diclofenac (IV) to HPβCD-diclofenac (IM) for AUC0-t was 101.25%. The geometric mean ratio of HPβCD-diclofenac (IM) to Voltarol (IV) for AUC0-t was 104.96%. Study 2: Cmax for diclofenac was 2904 and 6031 ng/ml after the first IV dose of 18.75 and 37.5 mg HPβCD-diclofenac, respectively, and was 3090 and 5617 ng/ml after the fourth dose, indicating no accumulation. Plasma exposures to 18.75 mg (866 ng·hour/ml) and 37.5 mg (1843 ng·hour/ml) IV HPβCD-diclofenac bracketed that of oral Cataflam 50 mg (1473 ng·hour/ml). Study 1: Bioavailability in terms of AUC after IV administration was equivalent for HPβCD-diclofenac compared with Voltarol and after IM administration of HPβCD-diclofenac and Voltarol. Bioavailability in terms of AUC after IM administration of HPβCD-diclofenac was equivalent to IV administration of HP

  13. Contrast Dose and Radiation Dose Reduction in Abdominal Enhanced Computerized Tomography Scans with Single-phase Dual-energy Spectral Computerized Tomography Mode for Children with Solid Tumors.

    Science.gov (United States)

    Yu, Tong; Gao, Jun; Liu, Zhi-Min; Zhang, Qi-Feng; Liu, Yong; Jiang, Ling; Peng, Yun

    2017-04-05

    Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors. Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled. The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast, and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode. Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A. In addition, filtered back-projection (FBP) reconstruction was used for monochromatic images hounsfield unit (HU). The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t = 0.36 and -1.716 for liver, -0.153 and -1.546 for pancreas, and 2.427 and 0.866 for renal cortex, all P> 0.05). Signal-to-noise ratio of the abdominal organs was significantly lower in Group A than in Group B (t = -8.11 for liver, -7.83 for pancreas, and -5.38 for renal cortex, all P 3, indicating clinically acceptable image quality. Single-phase, dual-energy spectral CT used for children with solid abdominal tumors can reduce contrast dose and radiation dose and can also maintain clinically acceptable image quality.

  14. Heating limits of boiling downward two-phase flow in parallel channels

    International Nuclear Information System (INIS)

    Fukuda, Kenji; Kondoh, Tetsuya; Hasegawa, Shu; Sakai, Takaaki.

    1989-01-01

    Flow characteristics and heating limits of downward two-phase flow in single or parallel multi-channels are investigated experimentally and analytically. The heating section used is made of glass tube, in which the heater tube is inserted, and the flow regime inside it is observed. In single channel experiments with low flow rate conditions, it is found that, initially, gas phase which flows upward against the downward liquid phase flow condenses and diminishes as it flows up being cooled by inflowing liquid. However, as the heating power is increased, some portion of the gas phase reaches the top and accumulates to form an liquid level, which eventually causes the dryout. On the other hand, for high flow rate condition, the flooding at the bottom of the heated section is the cause of the dryout. In parallel multi-channels experiments, reversed (upward) flow which leads to the dryout is observed in some of these channels for low flow rate conditions, while the situation is the same to the single channel case for high flow rate conditions. Analyses are carried out to predict the onset of dryout in single channel using the drift flux model as well as the Wallis' flooding correlation. Above-mentioned two types of the dryout and their boundary are predicted which agree well with the experimental results. (author)

  15. Pharmacokinetic comparison of controlled-release and immediate-release oral formulations of simvastatin in healthy Korean subjects: a randomized, open-label, parallel-group, single- and multiple-dose study.

    Science.gov (United States)

    Jang, Seong Bok; Lee, Yoon Jung; Lim, Lay Ahyoung; Park, Kyung-Mi; Kwon, Bong-Ju; Woo, Jong Soo; Kim, Yong-Il; Park, Min Soo; Kim, Kyung Hwan; Park, Kyungsoo

    2010-01-01

    A controlled-release (CR) formulation of simvastatin was recently developed in Korea. The formulation is expected to yield a lower C(max) and similar AUC values compared with the immediate-release (IR) formulation. The goal of this study was to compare the pharmacokinetics of the new CR formulation and an IR formulation of simvastatin after single- and multiple-dose administration in healthy Korean subjects. This study was developed as part of a product development project at the request of the Korean regulatory agency. This was a randomized, open-label, parallelgroup, 2-part study. Eligible subjects were healthy male or female volunteers between the ages of 19 and 55 years and within 20% of their ideal weight. In part I, each subject received a single dose of the CR or IR formulation of simvastatin 40 mg orally (20 mg x 2 tablets) after fasting. In part II, each subject received the same dose of the CR or IR formulation for 8 consecutive days. Blood samples were obtained for 48 hours after the dose in part I and after the first and the last dose in part II. Pharmacokinetic parameters were determined for both simvastatin (the inactive prodrug) and simvastatin acid (the active moiety). An adverse event (AE) was defined as any unfavorable sign (including an abnormal laboratory finding) or symptom, regardless of whether it had a causal relationship with the study medication. Serious AEs were defined as any events that are considered life threatening, require hospitalization or prolongation of existing hospitalization, cause persistent or significant disability or incapacity, or result in congenital abnormality, birth defect, or death. AEs were determined based on patient interviews and physical examinations. Twenty-four healthy subjects (17 men, 7 women; mean [SD] age, 29 [7] years; age range, 22-50 years) were enrolled in part I, and 29 subjects (17 men, 12 women; mean age, 33 [9] years; age range, 19-55 years) were enrolled in part II. For simvastatin acid, C

  16. Evaluation of fleroxacin (RO 23-6240) as single-oral-dose therapy of culture-proven chancroid in Nairobi, Kenya.

    Science.gov (United States)

    MacDonald, K S; Cameron, D W; D'Costa, L; Ndinya-Achola, J O; Plummer, F A; Ronald, A R

    1989-01-01

    Chancroid is gaining importance as a sexually transmitted disease because of its association with transmission of human immunodeficiency virus type 1 (HIV-1). Effective, simply administered therapy for chancroid is necessary. Fleroxacin is effective against Haemophilus ducreyi in vitro. We performed an initial randomized clinical trial to assess the efficacy of fleroxacin for treatment of chancroid in Nairobi, Kenya. Fifty-three men with culture-positive chancroid were randomly assigned to receive either 200 mg (group 1) or 400 mg (group 2) of fleroxacin as a single oral dose. Groups 1 and 2 were similar with regard to severity of disease, bubo formation, and HIV-1 status. A satisfactory clinical response to therapy was noted in 23 of 26 patients (88%) in group 1 and 18 of 23 patients (78%) in group 2. Bacteriological failure occurred in 1 of 26 evaluable patients (4%) in group 1 and 4 of 23 evaluable patients (17%) in group 2. Two of 37 HIV-1-seronegative men (5%) and 3 of 11 HIV-1-infected men (27%) were bacteriological failures. Fleroxacin, 200 or 400 mg as a single oral dose, is efficacious therapy for microbiologically proven chancroid in patients who do not have concurrent HIV-1 infection. Among HIV-1-infected men, a single dose of 200 or 400 mg of fleroxacin is inadequate therapy for chancroid. PMID:2502065

  17. Efficacy of chlorophyll c2 for seasonal allergic rhinitis: single-center double-blind randomized control trial.

    Science.gov (United States)

    Fujiwara, Takashi; Nishida, Naoya; Nota, Jumpei; Kitani, Takashi; Aoishi, Kunihide; Takahashi, Hirotaka; Sugahara, Takuya; Hato, Naohito

    2016-12-01

    Chlorophyll c2 extracted from Sargassum horneri improved allergic symptoms in an animal model of allergic rhinitis. In the present study, we explored the efficacy of chlorophyll c2 in patients with seasonal allergic rhinitis. This was a single-center, randomized, double-blind placebo-controlled trial. Sixty-six patients aged 20-43 years, each with a 2-year history of seasonal allergic rhinitis, were randomly assigned to receive either a single daily dose (0.7 mg) of chlorophyll c2 or placebo for 12 weeks. The use of medications including H1-antihistamines and topical nasal steroids was recorded by rescue medication scores (RMSs) noted after 4, 8, and 12 weeks of treatment. Disease-specific quality of life was measured using the Japan Rhinitis Quality of Life Questionnaire (JRQLQ) both before and after 4, 8, and 12 weeks of treatment. The RMS at 8 weeks was significantly better in the chlorophyll c2 than the placebo group (mean RMS difference = -3.09; 95 % confidence interval = -5.96 to -0.22); the mean RMS at 4 weeks was only slightly better in the chlorophyll c2 group. The JRQLQ scores did not differ significantly between the two groups. Chlorophyll c2 would have a potential to be an alternative treatment for allergic rhinitis.

  18. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Martine, Remy-Jardin; Colas, Lucie; Jean-Baptiste, Faivre; Remy, Jacques [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Santangelo, Teresa [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Bambino Gesu Children' s Hospital, Department of Imaging, Rome (Italy); Duhamel, Alain [University of Lille (EA 2694), Department of Biostatistics, CHU Lille, Lille (France); Deschildre, Antoine [CHU Lille - University of Lille, Department of Pediatric Pulmonology, Lille (France)

    2017-02-15

    The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution. To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children. We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage. CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol{sub 32}) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP{sub 32} was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP{sub 32}, CTDI{sub vol32} and SSDE were found to be statistically significant in the five weight categories (P < 0.0001). This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP{sub 32}, 0.78-1.25 mGy for the CTDI{sub vol32} and 1.6-2.1 mGy for the SSDE. (orig.)

  19. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT

    International Nuclear Information System (INIS)

    Martine, Remy-Jardin; Colas, Lucie; Jean-Baptiste, Faivre; Remy, Jacques; Santangelo, Teresa; Duhamel, Alain; Deschildre, Antoine

    2017-01-01

    The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution. To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children. We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage. CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol 32 ) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP 32 was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP 32 , CTDI vol32 and SSDE were found to be statistically significant in the five weight categories (P < 0.0001). This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP 32 , 0.78-1.25 mGy for the CTDI vol32 and 1.6-2.1 mGy for the SSDE. (orig.)

  20. A Single-Dose, Single-Period Pharmacokinetic Assessment of an Extended-Release Orally Disintegrating Tablet of Methylphenidate in Children and Adolescents with Attention-Deficit/Hyperactivity Disorder.

    Science.gov (United States)

    Childress, Ann; Newcorn, Jeffrey; Stark, Jeffrey G; McMahen, Russ; Tengler, Mark; Sikes, Carolyn

    2016-08-01

    To determine the pharmacokinetic (PK) profile of a proprietary formulation of methylphenidate (MPH) in children and adolescents with attention-deficit/hyperactivity disorder (ADHD) in a phase 1 study. Methylphenidate extended-release orally disintegrating tablets (MPH XR-ODTs) combine two technologies in a single-tablet formulation-an extended-release profile that was designed for once-daily dosing in an ODT that does not require water or chewing for ingestion. This was a single-dose, open-label, single-period, single-treatment study, in which 32 children with ADHD who were receiving MPH in doses of 40 or 60 mg before beginning the study each received a 60-mg dose (2 × 30 mg) of MPH XR-ODT. The following plasma PK parameters of MPH were determined for participants grouped by age (6-7, 8-9, 10-12, and 13-17 years old): maximum concentration (Cmax), time to maximum concentration (Tmax), elimination half-life (T½), area under the curve from 0 hours to infinity (AUCinf), oral clearance (CL/F), and volume of distribution in the terminal phase (Vz/F). Safety and tolerability were also assessed. A total of 32 participants received the study drug. For all participants, plasma concentration-time profiles of MPH exhibited a broad peak after administration of MPH XR-ODT through ∼8 hours, indicating extended release from the formulation, followed by an apparent first-order elimination phase. As age increased, MPH exposure decreased and mean estimates of CL/F increased; however, weight-normalized CL/F values were comparable across age groups. Similarly, mean estimates of Vz/F increased with age, but weight-normalization decreased differences across age groups, with the exception of the youngest age group, which had higher values. All adverse events (AEs) were mild. This XR-ODT formulation of MPH demonstrated weight-normalized clearance rates that were consistent across all age groups, a PK profile consistent with once-daily dosing, and an AE profile consistent with

  1. Single dose planning for radioiodine-131 therapy of Graves' disease

    International Nuclear Information System (INIS)

    Kita, Tamotsu; Yokoyama, Kunihiko; Kinuya, Seigo; Taki, Junichi; Michigishi, Takatoshi; Tonami, Norihisa

    2004-01-01

    Patients with Graves' disease were studied one year after radioiodine-131 therapy to assess the relationship between the effectiveness of the therapy and the radioiodine doses used. Patients were classified into three groups according to thyroid function as hyperthyroidism, euthyroidism and hypothyroidism at one year after I-131 therapy. In these groups we compared the mean values of dose, dose per thyroid weight calculated with I-123 uptake before the therapy (pre D/W), dose per thyroid weight calculated with therapeutic I-131 uptake (post D/W), and absorbed dose. No significant differences were found between the three groups in terms of dose or pre D/W. The mean values of post D/W and absorbed dose in the non-hyperthyroid (euthyroid and hypothyroid) group were significantly greater than those in the hyperthyroid group. Post D/W of 6.3 MBq/g was a threshold separating the non-hyperthyroid group from the hyperthyroid group. There was no correlation between pre D/W and post D/W; however, the mean post D/W was significantly greater than the mean pre D/W. All patients with pre D/W above 6.3 MBq/g showed non-hyperthyroidism at one year after the radioiodine treatment. No indicators before the radioiodine therapy had significant relationships with the effectiveness of the therapy at one year after the treatment. However, the single therapy planned for setting the pre D/W above 6.3 MBq/g will certainly make the patients non-hyperthyroid. As this proposal of dose planning is based on a small number of patients, further study is needed. (author)

  2. Developing a single-aliquot protocol for measuring equivalent dose in biogenic carbonates

    International Nuclear Information System (INIS)

    Stirling, R.J.; Duller, G.A.T.; Roberts, H.M.

    2012-01-01

    Exploiting biogenic carbonates as thermoluminescence dosimeters requires an understanding of trap kinetics and an appropriate sequence with which to measure equivalent dose. The trap kinetics of two high temperature peaks (peaks II and III) from calcitic snail opercula have been investigated resulting in the calculation of lifetimes of 7.4 × 10 7 and 1.4 × 10 11 years for the two peaks respectively. Two measurement sequences, based upon changes in the application and measurement of a test dose, have been applied to peaks II and III, and though both methods were equally successful in dose recovery and production of a dose response curve some differences were observed. Primarily, the use of method 1 lead to dose dependant sensitivity change implying competition effects occurring during irradiation; method 2 did not experience this phenomenon. As a consequence method 2 was chosen as the most appropriate protocol for single-aliquot dating of this material. When assessing the TL behaviour of the two peaks, peak II performed poorly in dose recovery experiments recovering a dose 60–100% larger than that applied. Disproportionate growth of peak II in response to a beta dose applied prior to measurement, compared to growth following regeneration doses indicated that peak II was not suitable for use in single-aliquot protocols. However, dose recovery results for peak III were all within errors of unity of the given dose, and peak III was therefore chosen as the most appropriate peak for TL dosimetry in these single-aliquot procedures. The lifetime of charge in peak III is sufficient to date over many millions of years, and furthermore using the chosen method 2 the dose response curve has a D 0 of 3,250 ± 163 Gy allowing dating to over 3 million years.

  3. Parallel and Serial Grouping of Image Elements in Visual Perception

    Science.gov (United States)

    Houtkamp, Roos; Roelfsema, Pieter R.

    2010-01-01

    The visual system groups image elements that belong to an object and segregates them from other objects and the background. Important cues for this grouping process are the Gestalt criteria, and most theories propose that these are applied in parallel across the visual scene. Here, we find that Gestalt grouping can indeed occur in parallel in some…

  4. Parallel computational in nuclear group constant calculation

    International Nuclear Information System (INIS)

    Su'ud, Zaki; Rustandi, Yaddi K.; Kurniadi, Rizal

    2002-01-01

    In this paper parallel computational method in nuclear group constant calculation using collision probability method will be discuss. The main focus is on the calculation of collision matrix which need large amount of computational time. The geometry treated here is concentric cylinder. The calculation of collision probability matrix is carried out using semi analytic method using Beckley Naylor Function. To accelerate computation speed some computer parallel used to solve the problem. We used LINUX based parallelization using PVM software with C or fortran language. While in windows based we used socket programming using DELPHI or C builder. The calculation results shows the important of optimal weight for each processor in case there area many type of processor speed

  5. Single point estimation of phenytoin dosing: a reappraisal.

    Science.gov (United States)

    Koup, J R; Gibaldi, M; Godolphin, W

    1981-11-01

    A previously proposed method for estimation of phenytoin dosing requirement using a single serum sample obtained 24 hours after intravenous loading dose (18 mg/Kg) has been re-evaluated. Using more realistic values for the volume of distribution of phenytoin (0.4 to 1.2 L/Kg), simulations indicate that the proposed method will fail to consistently predict dosage requirements. Additional simulations indicate that two samples obtained during the 24 hour interval following the iv loading dose could be used to more reliably predict phenytoin dose requirement. Because of the nonlinear relationship which exists between phenytoin dose administration rate (RO) and the mean steady state serum concentration (CSS), small errors in prediction of the required RO result in much larger errors in CSS.

  6. A comparison of two treatments for childhood apraxia of speech: methods and treatment protocol for a parallel group randomised control trial

    Directory of Open Access Journals (Sweden)

    Murray Elizabeth

    2012-08-01

    Full Text Available Abstract Background Childhood Apraxia of Speech is an impairment of speech motor planning that manifests as difficulty producing the sounds (articulation and melody (prosody of speech. These difficulties may persist through life and are detrimental to academic, social, and vocational development. A number of published single subject and case series studies of speech treatments are available. There are currently no randomised control trials or other well designed group trials available to guide clinical practice. Methods/Design A parallel group, fixed size randomised control trial will be conducted in Sydney, Australia to determine the efficacy of two treatments for Childhood Apraxia of Speech: 1 Rapid Syllable Transition Treatment and the 2 Nuffield Dyspraxia Programme – Third edition. Eligible children will be English speaking, aged 4–12 years with a diagnosis of suspected CAS, normal or adjusted hearing and vision, and no comprehension difficulties or other developmental diagnoses. At least 20 children will be randomised to receive one of the two treatments in parallel. Treatments will be delivered by trained and supervised speech pathology clinicians using operationalised manuals. Treatment will be administered in 1-hour sessions, 4 times per week for 3 weeks. The primary outcomes are speech sound and prosodic accuracy on a customised 292 item probe and the Diagnostic Evaluation of Articulation and Phonology inconsistency subtest administered prior to treatment and 1 week, 1 month and 4 months post-treatment. All post assessments will be completed by blinded assessors. Our hypotheses are: 1 treatment effects at 1 week post will be similar for both treatments, 2 maintenance of treatment effects at 1 and 4 months post will be greater for Rapid Syllable Transition Treatment than Nuffield Dyspraxia Programme treatment, and 3 generalisation of treatment effects to untrained related speech behaviours will be greater for Rapid

  7. A comparison of traditional vs. Canadian tailored prophylaxis dosing of prophylactic factor infusions in children with haemophilia A and B in a single hemophilia treatment center.

    Science.gov (United States)

    Dodd, C; Watts, R G

    2012-07-01

    Prophylactic infusion of clotting factor concentrates is a developing standard of care for individuals with haemophilia. The ideal schedule and techniques of prophylactic infusions remain incompletely defined. Our aim was to determine the optimal techniques and schedules for factor prophylaxis in paediatric patients. A retrospective electronic medical record review of all children treated with prophylactic factor infusions in a single Haemophilia Treatment Center was conducted. Comparison of traditional vs. Canadian dosing regimens and primary vs. secondary prophylaxis was made. Failure of prophylaxis was defined as the first serious bleed. A total of 58 children were identified for review. Five cases were excluded (four due to high titre inhibitors and one due to repeated non-compliance), thus there were 53 total cases: 46 with severe haemophilia, 2 with moderate haemophilia, 5 with mild haemophilia, 44 with haemophilia A and 9 with haemophilia B; 32 Traditional dosing and 21 Canadian dosing regimens. Patients on primary prophylaxis had a decreased failure rate (25%) compared to children treated with secondary prophylaxis (67%) regardless of technique of prophylaxis. When compared to a 'Traditional' factor prophylaxis schedule, the 'Canadian' tailored prophylaxis protocol was comparable with the exception of a decreased use of implanted venous devices in the 'Canadian' group. Ongoing bleeding (primarily joint bleeds) occurs with all prophylactic regimens. The lowest incidence of treatment failure was noted in children who began primary prophylaxis at a young age and before initial joint bleeds. Primary prophylaxis is superior to secondary prophylaxis regardless of dosing regimen. Traditional and Canadian dosing regimens were equivalent in outcome when measured over several years of follow-up. © 2012 Blackwell Publishing Ltd.

  8. SU-F-J-146: Experimental Validation of 6 MV Photon PDD in Parallel Magnetic Field Calculated by EGSnrc

    Energy Technology Data Exchange (ETDEWEB)

    Ghila, A; Steciw, S; Fallone, B; Rathee, S [Cross Cancer Institute, Edmonton, AB (Canada)

    2016-06-15

    Purpose: Integrated linac-MR systems are uniquely suited for real time tumor tracking during radiation treatment. Understanding the magnetic field dose effects and incorporating them in treatment planning is paramount for linac-MR clinical implementation. We experimentally validated the EGSnrc dose calculations in the presence of a magnetic field parallel to the radiation beam travel. Methods: Two cylindrical bore electromagnets produced a 0.21 T magnetic field parallel to the central axis of a 6 MV photon beam. A parallel plate ion chamber was used to measure the PDD in a polystyrene phantom, placed inside the bore in two setups: phantom top surface coinciding with the magnet bore center (183 cm SSD), and with the magnet bore’s top surface (170 cm SSD). We measured the field of the magnet at several points and included the exact dimensions of the coils to generate a 3D magnetic field map in a finite element model. BEAMnrc and DOSXYZnrc simulated the PDD experiments in parallel magnetic field (i.e. 3D magnetic field included) and with no magnetic field. Results: With the phantom surface at the top of the electromagnet, the surface dose increased by 10% (compared to no-magnetic field), due to electrons being focused by the smaller fringe fields of the electromagnet. With the phantom surface at the bore center, the surface dose increased by 30% since extra 13 cm of air column was in relatively higher magnetic field (>0.13T) in the magnet bore. EGSnrc Monte Carlo code correctly calculated the radiation dose with and without the magnetic field, and all points passed the 2%, 2 mm Gamma criterion when the ion chamber’s entrance window and air cavity were included in the simulated phantom. Conclusion: A parallel magnetic field increases the surface and buildup dose during irradiation. The EGSnrc package can model these magnetic field dose effects accurately. Dr. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi

  9. Optimizing a single fixed dose of Iodine-131 in Graves' Disease (An Experience)

    International Nuclear Information System (INIS)

    Khan, S.H.

    2007-01-01

    Full text: Kashmir is a Himalayan mountain state of India enclosed by high snow capped ridges of Pir Panjal Mountains at an average height of 4000-5000 meters above the sea level. For most of the 4 million inhabitants in this land locked valley, agriculture horticulture and handcrafts are the main source of income. Due to long and severe winters the terraced farming on the mountain slopes yield just a single crop of rice which is barely sufficient to meet the local needs of this staple diet. People are relatively poor with low annual per capita income. Goiter is endemic in the Valley of Kashmir. In a published report the overall prevalence of goiter among the school going children in Kashmir between the ages of 5 years is 45.2% (+ SEM) with urinary iodine excretion of 49 + 3.55 μg per gram of creatinine. The extremely shy people of Kashmir are casual towards the aesthetic aspects of their goiters but nevertheless seek medical advice when associated with physical symptoms. In a published study of 203 patients of thyrotoxicosis from Kashmir, Graves' disease was the commonest cause, accounting for 63% of patients. One hundred and twentyone patients of Graves' disease were prospectively studied for their response to a single fixed dose of I-131. Patients were randomly treated with two different fixed doses of I- 131. Sixty four patients belonging to Group-I received a fixed dose of 185 MBq (Low Dose) and 57 patients belonging to Group -2 received 370 MBq (High Dose) of I- 131. Following therapy all patients were evaluated at 3 months. Patients with normal or reduced thyroid hormone levels were termed as responders and those with persistently elevated levels of thyroid hormone were termed as non responders. The response rates among the two groups were analyzed for their statistical significance. Patients treated with the high fixed dose of 370 MBq revealed good response to therapy achieving a rate of 91.22%, while the response rate in the group of patients treated with

  10. A single dose of dark chocolate increases parasympathetic modulation and heart rate variability in healthy subjects

    Directory of Open Access Journals (Sweden)

    Ana Amélia Machado DUARTE

    Full Text Available ABSTRACT Objective: The aim of this study was to investigate the acute effect of a single dose of dark chocolate (70% cocoa on blood pressure and heart rate variability. Methods: Thirty-one healthy subjects (aged 18-25 years; both sexes were divided into two groups: 10 subjects in the white chocolate (7.4 g group and 21 in the dark chocolate (10 g group; measurements were performed at the university's physiology lab. An electrocardiogram measured the sympathovagal balance by spectral and symbolic analysis. Results: A single dose of dark chocolate significantly reduced systolic blood pressure and heart rate. After consuming 10 g of dark chocolate, significant increases were observed for heart rate variability, standard deviation of RR intervals standard deviation of all NN intervals, square root of the mean squared differences between adjacent normal RR intervals root mean square of successive differences, and an increase in the high frequency component in absolute values, representing the parasympathetic modulation. Conclusion: In conclusion the importance of our results lies in the magnitude of the response provoked by a single dose of cocoa. Just 10 g of cocoa triggered a significant increase in parasympathetic modulation and heart rate variability. These combined effects can potentially increase life expectancy because a reduction in heart rate variability is associated with several cardiovascular diseases and higher mortality.

  11. Gamma radiation-induced Impairment of hippocampal neurogenesis, comparison of single and fractionated dose regimens

    International Nuclear Information System (INIS)

    Khoshbin khoshnazar, A. R; Jahanshahi, M; Azami, N. S

    2012-01-01

    Radiation therapy of the brain is associated with many consequences, including cognitive disorders. Pathogenesis of radiation induced cognitive disorder is not clear, but reduction of neurogenesis in hippocampus may be an underlying reason. 24 adult male rats entered to study. Radiation absorbed dose to midbrain was 10 Gy, delivered by routine cobalt radiotherapy machine which its output was measured 115.24 cGy/min. The rats were divided in four groups of sixes, including groups of control, single fraction 10 Gy, fractionated 10 Gy and finally anaesthesia sham group. Number of pyramidal nerve cells was counted in two regions of hippocampus formation (CA1 and CA3). The radiation could reduce the number of cells in two regions of hippocampus significantly (p=0.000). It seems fractionated 10 Gy irradiation to more efficient than single fraction, while role of anaesthesia drug should be cautiously assessed. Moreover the rate of neurogenesis reduction was determined the same in these regions of hippocampus meaning the same radiosensitivity of cells

  12. Multiple single-centered attractors

    International Nuclear Information System (INIS)

    Dominic, Pramod; Mandal, Taniya; Tripathy, Prasanta K.

    2014-01-01

    In this paper we study spherically symmetric single-centered attractors in N=2 supergravity in four dimensions. The attractor points are obtained by extremising the effective black hole potential in the moduli space. Both supersymmetric as well as non-supersymmetric attractors exist in mutually exclusive domains of the charge lattice. We construct axion free supersymmetric as well as non-supersymmetric multiple attractors in a simple two parameter model. We further obtain explicit examples of two distinct non-supersymmetric attractors in type IIA string theory compactified on K3×T"2 carrying D0−D4−D6 charges. We compute the entropy of these attractors and analyse their stability in detail.

  13. Single Low-Dose Ionizing Radiation Induces Genotoxicity in Adult Zebrafish and its Non-Irradiated Progeny.

    Science.gov (United States)

    Lemos, J; Neuparth, T; Trigo, M; Costa, P; Vieira, D; Cunha, L; Ponte, F; Costa, P S; Metello, L F; Carvalho, A P

    2017-02-01

    This study investigated to what extent a single exposure to low doses of ionizing radiation can induce genotoxic damage in irradiated adult zebrafish (Danio rerio) and its non-irradiated F1 progeny. Four groups of adult zebrafish were irradiated with a single dose of X-rays at 0 (control), 100, 500 and 1000 mGy, respectively, and couples of each group were allowed to reproduce following irradiation. Blood of parental fish and whole-body offspring were analysed by the comet assay for detection of DNA damage. The level of DNA damage in irradiated parental fish increased in a radiation dose-dependent manner at day 1 post-irradiation, but returned to the control level thereafter. The level of DNA damage in the progeny was directly correlated with the parental irradiation dose. Results highlight the genotoxic risk of a single exposure to low-dose ionizing radiation in irradiated individuals and also in its non-irradiated progeny.

  14. Self-monitoring of urinary salt excretion as a method of salt-reduction education: a parallel, randomized trial involving two groups.

    Science.gov (United States)

    Yasutake, Kenichiro; Miyoshi, Emiko; Misumi, Yukiko; Kajiyama, Tomomi; Fukuda, Tamami; Ishii, Taeko; Moriguchi, Ririko; Murata, Yusuke; Ohe, Kenji; Enjoji, Munechika; Tsuchihashi, Takuya

    2018-02-20

    The present study aimed to evaluate salt-reduction education using a self-monitoring urinary salt-excretion device. Parallel, randomized trial involving two groups. The following parameters were checked at baseline and endline of the intervention: salt check sheet, eating behaviour questionnaire, 24 h home urine collection, blood pressure before and after urine collection. The intervention group self-monitored urine salt excretion using a self-measuring device for 4 weeks. In the control group, urine salt excretion was measured, but the individuals were not informed of the result. Seventy-eight individuals (control group, n 36; intervention group, n 42) collected two 24 h urine samples from a target population of 123 local resident volunteers. The samples were then analysed. There were no differences in clinical background or related parameters between the two groups. The 24 h urinary Na:K ratio showed a significant decrease in the intervention group (-1·1) compared with the control group (-0·0; P=0·033). Blood pressure did not change in either group. The results of the salt check sheet did not change in the control group but were significantly lower in the intervention group. The score of the eating behaviour questionnaire did not change in the control group, but the intervention group showed a significant increase in eating behaviour stage. Self-monitoring of urinary salt excretion helps to improve 24 h urinary Na:K, salt check sheet scores and stage of eating behaviour. Thus, usage of self-monitoring tools has an educational potential in salt intake reduction.

  15. Single-dose radiosurgical treatment for hepatic metastases - therapeutic outcome of 138 treated lesions from a single institution

    International Nuclear Information System (INIS)

    Habermehl, Daniel; Herfarth, Klaus K; Bermejo, Justo Lorenzo; Hof, Holger; Rieken, Stefan; Kuhn, Sabine; Welzel, Thomas; Debus, Jürgen; Combs, Stephanie E

    2013-01-01

    Local ablative therapies such as stereotactically guided single-dose radiotherapy or helical intensity-modulated radiotherapy (tomotherapy) with high single-doses are successfully applied in many centers in patients with liver metastasis not suitable for surgical resection. This study presents results from more than 10 years of clinical experience and evaluates long-term outcome and efficacy of this therapeutic approach. From 1997 to 2009 a total of 138 intrahepatic tumors of 90 patients were irradiated with single doses of 17 to 30 Gy (median dose 24 Gy). Median age of the patients was 64 years (range 31–89 years). Most frequent underlying tumor histologies were colorectal adenocarcinoma (70 lesions) and breast cancer (27 lesions). In 35 treatment sessions multiple targets were simultaneously irradiated (up to four lesions at once). Local progression-free (PFS) and overall survival (OS) after treatment were investigated using uni- and multiple survival regression models. Median overall survival of all patients was 24.3 months. Local PFS was 87%, 70% and 59% after 6, 12 and 18 months, respectively. Median time to local progression was 25.5 months. Patients with a single lesion and no further metastases at time of RT had a favorable median PFS of 43.1 months according to the Kaplan-Meier estimator. The type of tumor showed a statistical significant influence on local PFS, with a better prognosis for breast cancer histology than for colorectal carcinoma in uni- and multiple regression analysis (p = 0.05). Multiple regression analysis revealed no influence of planning target volume (PTV), patient age and radiation dose on local PFS. Treatment was well tolerated with no severe adverse events. This study confirms safety of SBRT in liver lesions, with 6- and 12 months local control of 87% and 70%. The dataset represents the clinical situation in a large oncology setting, with many competing treatment options and heterogeneous patient characteristics

  16. Single-shot parallel full range complex Fourier-domain optical coherence tomography

    International Nuclear Information System (INIS)

    Huang Bingjie; Bu Peng; Nan Nan; Wang Xiangzhao

    2011-01-01

    We present a method of parallel full range complex Fourier-domain optical coherence tomography (FDOCT) that is capable of acquiring an artifacts-free two-dimensional (2-D) cross-sectional image, i.e. a full range B-scan tomogram, by a single shot of 2-D CCD camera. This method is based on a spatial carrier technique, in which the spatial carrier-frequency is instantaneously introduced into the 2-D spectral interferogram registered in parallel FDOCT by using a grating-generated reference beam. The spatial-carrier-contained 2-D spectral interferogram is processed through Fourier transformation to obtain a complex 2-D spectral interferogram. From the 2-D complex spectral interferomgram, a full range B-scan tomogram is reconstructed. The principle of our method is confirmed by imaging an onion sample.

  17. A comparison of a single-dose and a seven-day treatment with Amoxicillin in asymptomatic bacteriuria in pregnancy

    OpenAIRE

    Niro Manesh S; Amiri A; Ali yari Sh

    1994-01-01

    In this study, 1600 pregnant women who had referred to two prenatal clinics (Imam Khomeini and Mirza Kochek-Khan) were investigated. Ninety cases of asymptomatic bacteriuria were observed; 77 of those cooperated with us until the end of our study. The subjects, who were within the 14-36 weeks of gestational age, were randomly divided into two groups: Group A received the medicine (Amoxicillin) in a single-dose (3gr.); and, group B received it within seven days (1gr. TDS). The rate of recovery...

  18. Efficacy of Single-Dose and Triple-Dose Albendazole and Mebendazole against Soil-Transmitted Helminths and Taenia spp.: A Randomized Controlled Trial

    Science.gov (United States)

    Steinmann, Peter; Utzinger, Jürg; Du, Zun-Wei; Jiang, Jin-Yong; Chen, Jia-Xu; Hattendorf, Jan; Zhou, Hui; Zhou, Xiao-Nong

    2011-01-01

    Background The control of soil-transmitted helminth (STH) infections currently relies on the large-scale administration of single-dose oral albendazole or mebendazole. However, these treatment regimens have limited efficacy against hookworm and Trichuris trichiura in terms of cure rates (CR), whereas fecal egg reduction rates (ERR) are generally high for all common STH species. We compared the efficacy of single-dose versus triple-dose treatment against hookworm and other STHs in a community-based randomized controlled trial in the People's Republic of China. Methodology/Principal findings The hookworm CR and fecal ERR were assessed in 314 individuals aged ≥5 years who submitted two stool samples before and 3–4 weeks after administration of single-dose oral albendazole (400 mg) or mebendazole (500 mg) or triple-dose albendazole (3×400 mg over 3 consecutive days) or mebendazole (3×500 mg over 3 consecutive days). Efficacy against T. trichiura, Ascaris lumbricoides, and Taenia spp. was also assessed. Albendazole cured significantly more hookworm infections than mebendazole in both treatment regimens (single dose: respective CRs 69% (95% confidence interval [CI]: 55–81%) and 29% (95% CI: 20–45%); triple dose: respective CRs 92% (95% CI: 81–98%) and 54% (95% CI: 46–71%)). ERRs followed the same pattern (single dose: 97% versus 84%; triple dose: 99.7% versus 96%). Triple-dose regimens outperformed single doses against T. trichiura; three doses of mebendazole – the most efficacious treatment tested – cured 71% (95% CI: 57–82%). Both single and triple doses of either drug were highly efficacious against A. lumbricoides (CR: 93–97%; ERR: all >99.9%). Triple dose regimens cured all Taenia spp. infections, whereas single dose applications cured only half of them. Conclusions/Significance Single-dose oral albendazole is more efficacious against hookworm than mebendazole. To achieve high CRs against both hookworm and T. trichiura, triple-dose regimens are

  19. Single-center trials in neonatology: Issues to consider.

    Science.gov (United States)

    Sinha, Ian P; Sinha, Sunil K

    2015-12-01

    Single-center randomized controlled trials confer certain advantages over multi-center trials, in that they are cheaper and easier to design and conduct. However, recent research suggests that single-center trials are likely to overestimate treatment effects. There are notable examples in neonatology where results from multi-center trials have contradicted results of single-center studies. In this paper we discuss issues around external generalizability of single-center studies, and methodological issues that may cause bias. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Domain decomposition parallel computing for transient two-phase flow of nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Ryong; Yoon, Han Young [KAERI, Daejeon (Korea, Republic of); Choi, Hyoung Gwon [Seoul National University, Seoul (Korea, Republic of)

    2016-05-15

    KAERI (Korea Atomic Energy Research Institute) has been developing a multi-dimensional two-phase flow code named CUPID for multi-physics and multi-scale thermal hydraulics analysis of Light water reactors (LWRs). The CUPID code has been validated against a set of conceptual problems and experimental data. In this work, the CUPID code has been parallelized based on the domain decomposition method with Message passing interface (MPI) library. For domain decomposition, the CUPID code provides both manual and automatic methods with METIS library. For the effective memory management, the Compressed sparse row (CSR) format is adopted, which is one of the methods to represent the sparse asymmetric matrix. CSR format saves only non-zero value and its position (row and column). By performing the verification for the fundamental problem set, the parallelization of the CUPID has been successfully confirmed. Since the scalability of a parallel simulation is generally known to be better for fine mesh system, three different scales of mesh system are considered: 40000 meshes for coarse mesh system, 320000 meshes for mid-size mesh system, and 2560000 meshes for fine mesh system. In the given geometry, both single- and two-phase calculations were conducted. In addition, two types of preconditioners for a matrix solver were compared: Diagonal and incomplete LU preconditioner. In terms of enhancement of the parallel performance, the OpenMP and MPI hybrid parallel computing for a pressure solver was examined. It is revealed that the scalability of hybrid calculation was enhanced for the multi-core parallel computation.

  1. The Efficacy of Single-Dose versus Double-Dose Praziquantel Treatments on Schistosoma mansoni Infections: Its Implication on Undernutrition and Anaemia among Primary Schoolchildren in Two On-Shore Communities, Northwestern Tanzania

    Science.gov (United States)

    Buza, Joram; Mpolya, Emmanuel A.; Angelo, Teckla; Kinung'hi, Safari M.

    2017-01-01

    Administering more than one treatment may increase Praziquantel cure and egg reduction rates, thereby hastening achievement of schistosomiasis transmission control. A total of 431 S. mansoni-infected schoolchildren were randomized to receive either a single or repeated 40 mg/kg Praziquantel dose. Heights, weights, and haemoglobin levels were determined using a stadiometer, weighing scale, and HemoCue, respectively. At 8 weeks, cure rate was higher on repeated dose (93.10%) compared to single dose (68.68%) (p 0.05) and 8 (p > 0.05) months with no difference in reinfection rate. No difference in the prevalence of stunting was observed between the two treatment regimens (p > 0.05) at 8 months, but there was an increase in the prevalence of wasting among those on repeated dose (p 0.05). To achieve reduction of transmission intensity and disease control in highly endemic areas, repeated treatments alone may not be sufficient. This trial was registered with PACTR201601001416338. PMID:29094048

  2. Dose-reduction techniques for high-dose worker groups in nuclear power plants

    International Nuclear Information System (INIS)

    Khan, T.A.; Baum, J.W.; Dionne, B.J.

    1991-03-01

    This report summarizes the main findings of a study of the extent of radiation dose received by special work groups in the nuclear power industry. Work groups which chronically get large doses were investigated, using information provided by the industry. The tasks that give high doses to these work groups were examined and techniques described that were found to be particularly successful in reducing dose. Quantitative information on the extent of radiation doses to various work groups shows that significant numbers of workers in several critical groups receive doses greater than 1 and even 2 rem per year, particularly contract personnel and workers at BWR-type plants. The number of radiation workers whose lifetime dose is greater than their age is much less. Although the techniques presented would go some way in reducing dose, it is likely that a sizeable reduction to the high-dose work groups may require development of new dose-reduction techniques as well as major changes in procedures. 10 refs., 26 tabs

  3. Pharmacokinetics, Safety and Tolerability of Sacubitril/Valsartan (LCZ696) After Single-Dose Administration in Healthy Chinese Subjects.

    Science.gov (United States)

    Han, Yi; Ayalasomayajula, Surya; Pan, Wei; Yang, Fan; Yuan, Yaozong; Langenickel, Thomas; Hinder, Markus; Kalluri, Sampath; Pal, Parasar; Sunkara, Gangadhar

    2017-02-01

    Sacubitril/valsartan (LCZ696) is a first-in-class angiotensin receptor neprilysin inhibitor (ARNI) and has been recently approved in several countries for the treatment of patients with heart failure and reduced ejection fraction. This was the first study conducted to characterise the pharmacokinetics of LCZ696 analytes (pro-drug sacubitril, active neprilysin inhibitor LBQ657 and valsartan) after single-dose administration of LCZ696 in healthy Chinese subjects. In this open-label, randomised, parallel-group study, following screening and baseline evaluation, eligible healthy subjects received single oral doses of LCZ696 50, 100, 200 or 400 mg. The pharmacokinetics, safety and tolerability of LCZ696 were assessed up to 72 h after dosing. A total of 40 healthy male subjects were enrolled, and all completed the study. Following oral administration, LCZ696 delivered systemic exposure to sacubitril, LBQ657 and valsartan with a median time to reach maximum plasma concentration (T max ) ranging from 0.50 to 1.25, 2.00 to 3.00 and 1.50 to 2.50 h, respectively, over the investigated dose range. The mean terminal elimination half-life (T 1/2 ) ranged from 0.89 to 1.35, 8.57 to 9.24 and 5.33 to 7.91 h for sacubitril, LBQ657 and valsartan, respectively. The area under the plasma concentration-time curve from time zero to the time of the last quantifiable concentration (AUC 0-last ), and maximum plasma concentration (C max ) for LBQ657 increased dose proportionally over the entire dose range. Dose linear increase in the exposure was observed across the dose range for sacubitril and valsartan. LCZ696 was safe and well tolerated at all doses in this study. Adverse events of only mild intensity, which required no treatment, were reported in 6 (15 %) subjects. The pharmacokinetic profiles of LCZ696 analytes in Chinese subjects are similar to those reported previously in Caucasian subjects.

  4. Extended Kalman Filter Based Sliding Mode Control of Parallel-Connected Two Five-Phase PMSM Drive System

    Directory of Open Access Journals (Sweden)

    Tounsi Kamel

    2018-01-01

    Full Text Available This paper presents sliding mode control of sensor-less parallel-connected two five-phase permanent magnet synchronous machines (PMSMs fed by a single five-leg inverter. For both machines, the rotor speeds and rotor positions as well as load torques are estimated by using Extended Kalman Filter (EKF scheme. Fully decoupled control of both machines is possible via an appropriate phase transposition while connecting the stator windings parallel and employing proposed speed sensor-less method. In the resulting parallel-connected two-machine drive, the independent control of each machine in the group is achieved by controlling the stator currents and speed of each machine under vector control consideration. The effectiveness of the proposed Extended Kalman Filter in conjunction with the sliding mode control is confirmed through application of different load torques for wide speed range operation. Comparison between sliding mode control and PI control of the proposed two-motor drive is provided. The speed response shows a short rise time, an overshoot during reverse operation and settling times is 0.075 s when PI control is used. The speed response obtained by SMC is without overshoot and follows its reference and settling time is 0.028 s. Simulation results confirm that, in transient periods, sliding mode controller remarkably outperforms its counterpart PI controller.

  5. Accuracy determination of dose calibrators in Nuclear Medicine Centers using Tl-201

    International Nuclear Information System (INIS)

    Sattari, A.; Feizi, H.; Ghafoori, M.

    2008-01-01

    Full text: Correct administrated activity of radiopharmaceuticals is an important factor to ensure that administrated radiopharmaceutical is accurately measured and to avoid unnecessary exposure to patients. In this article, nuclear medicine group and Secondary Standard Dosimetry Laboratory (SSDL), has introduced a comparison study with 201 Tl to check the accuracy of dose calibrators in some nuclear medicine centers. First, the dose calibrator in cyclotron department was calibrated by SSDL using 133 Ba, 57 Co, 137 Cs and standard Europium sources. Then, 2ml produced 201 Tl solution containing 16±0.1 mCi was accurately sub-divided into a series of 10 ml Schott vials and delivered to 12 nuclear medicine centers that have been participated in this study. Participants were requested to assay their Schott vials in their dose calibrators at the same time and report the result on the especial sheet. Difference between the activities values reported by participants (A p ) with assayed activity on cyclotron department (Ac), defined as error value. In comparison of A c with A p , 10 centers (83%) has positive and 2 others (17%) has negative error. The range of positive error 2.6% -17.9% and range of negative error 5%-8.5%, by the average of 8.67 and %SD = 7.39 have been calculated. In conclusion, although nuclear medicine centers do calibration on their dose calibrators but establishment a regular audit system seems to be necessary. (author)

  6. Audit on dose delivery by using TLD in Radiotherapy Centers in Malaysia

    International Nuclear Information System (INIS)

    Md Saion Salikin; Taiman Kadni; Husaini Salleh; Asmaliza Hashim; Hasrul Husham Hussain

    2004-01-01

    The External Audit Group (EAQ) is established and supported by IAEA. Its main objective is to audit the accuracy of dose delivery to patients in radiotherapy centres or hospitals in developing countries in IAEA member states. At MINT the operation of EAG is managed by Medical Physics Group and supported by Secondary Standard Dosimetry Laboratory (SSDL), MINT. The selected radiotherapy centers are supplied with TLD powder in capsule form, to be irradiated with the required radiation doses, by their physicists. The irradiated TLD is analysed at SSDL. The result of the audit for a few radiotherapy centres in Malaysia, is presented in brief in this paper. (Author)

  7. A two-level parallel direct search implementation for arbitrarily sized objective functions

    Energy Technology Data Exchange (ETDEWEB)

    Hutchinson, S.A.; Shadid, N.; Moffat, H.K. [Sandia National Labs., Albuquerque, NM (United States)] [and others

    1994-12-31

    In the past, many optimization schemes for massively parallel computers have attempted to achieve parallel efficiency using one of two methods. In the case of large and expensive objective function calculations, the optimization itself may be run in serial and the objective function calculations parallelized. In contrast, if the objective function calculations are relatively inexpensive and can be performed on a single processor, then the actual optimization routine itself may be parallelized. In this paper, a scheme based upon the Parallel Direct Search (PDS) technique is presented which allows the objective function calculations to be done on an arbitrarily large number (p{sub 2}) of processors. If, p, the number of processors available, is greater than or equal to 2p{sub 2} then the optimization may be parallelized as well. This allows for efficient use of computational resources since the objective function calculations can be performed on the number of processors that allow for peak parallel efficiency and then further speedup may be achieved by parallelizing the optimization. Results are presented for an optimization problem which involves the solution of a PDE using a finite-element algorithm as part of the objective function calculation. The optimum number of processors for the finite-element calculations is less than p/2. Thus, the PDS method is also parallelized. Performance comparisons are given for a nCUBE 2 implementation.

  8. Dose finding study of granisetron in patients receiving high-dose cisplatin chemotherapy. The Granisetron Study Group.

    Science.gov (United States)

    Riviere, A.

    1994-01-01

    The efficacy and safety of three different doses of granisetron (2 micrograms kg-1, group A; 10 micrograms kg-1, group B; 40 micrograms kg-1, group C) were compared in a randomised, double-blind study of 157 patients due to receive high-dose cisplatin therapy (mean dose > 97 mg m-2). In each group, up to two 3 mg rescue doses of granisetron were allowed if more than mild nausea or vomiting occurred. In group A 30.8%, in group B 61.5% and in group C 67.9% of patients were complete responders (i.e. no vomiting or nothing worse than mild nausea) during the first 24 h. These differences are significant between groups A and B, and A and C. There were no statistically significant differences in any efficacy variable between the 10 micrograms kg-1 and 40 micrograms kg-1 groups, although in each case the trend favoured the higher dose. Additional rescue doses resulted in resolved or improved symptoms in 95.3% for the first rescue dose and 93.3% for the second. Over the 7 days of the study, 82.7%, 82.7% and 86.8% of patients in groups A, B and C respectively were treated with granisetron alone. Headache was the most common side-effect, reported by 9.6% of patients; the majority of headaches were mild. There was no difference between the treatment groups regarding the adverse event rate. We concluded that prophylactic doses of 10 or 40 micrograms kg-1 lead to a safe and satisfactory degree of control of nausea and vomiting induced by high-dose cisplatin. PMID:8180032

  9. Contemporary Parenteral Antiplatelet Bridging Strategies: A Single-Center Real-World Experience at a Tertiary Care Center.

    Science.gov (United States)

    Stern, Gretchen; Rimsans, Jessica; Qamar, Arman; Vaduganathan, Muthiah; Bhatt, Deepak L

    2018-03-13

    Oral antiplatelet therapy may require interruption soon after percutaneous coronary intervention (PCI) or acute coronary syndrome. The optimal parenteral antiplatelet bridge strategy with glycoprotein IIb/IIIa inhibitors or cangrelor, a P2Y12 inhibitor, is unclear. We explore real-world use of cangrelor or eptifibatide for antiplatelet bridging at a large tertiary-care center. Thirty-one patients (9 eptifibatide, 20 cangrelor, and 2 both) received bridge therapy from October 2015 to June 2017. Primary bridge therapy indications included surgery (68%), limited enteral access/absorption (16%), and high-perceived bleed risk (16%). Median duration of bridge therapy was 61 (20-100) hours for cangrelor and 83 (19-98) hours for eptifibatide. Severe/life-threatening bleeding or stent thrombosis was not observed. GUSTO-defined bleeding occurred in 30% (cangrelor) and 27% (eptifibatide). Initial dosing errors occurred in 23% of patients. Death during hospitalization occurred in 16% of patients. Parenteral antiplatelet bridging was used for ~3 days in this single-center, tertiary care experience, commonly for unplanned surgery following PCI. Despite high-risk presentations with >15% in-hospital mortality, efficacy profiles were reassuring with no identified stent thrombosis, but bleeding and dosing errors were common. Antiplatelet bridging should only be used in well-selected patients at the appropriate dose for the minimal necessary duration.

  10. Triple Arterial Phase MR Imaging with Gadoxetic Acid Using a Combination of Contrast Enhanced Time Robust Angiography, Keyhole, and Viewsharing Techniques and Two-Dimensional Parallel Imaging in Comparison with Conventional Single Arterial Phase

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jeong Hee [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Department of Radiology, Seoul National University College of Medicine, Seoul 03087 (Korea, Republic of); Lee, Jeong Min [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Department of Radiology, Seoul National University College of Medicine, Seoul 03087 (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03087 (Korea, Republic of); Yu, Mi Hye [Department of Radiology, Konkuk University Medical Center, Seoul 05030 (Korea, Republic of); Kim, Eun Ju [Philips Healthcare Korea, Seoul 04342 (Korea, Republic of); Han, Joon Koo [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Department of Radiology, Seoul National University College of Medicine, Seoul 03087 (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03087 (Korea, Republic of)

    2016-11-01

    To determine whether triple arterial phase acquisition via a combination of Contrast Enhanced Time Robust Angiography, keyhole, temporal viewsharing and parallel imaging can improve arterial phase acquisition with higher spatial resolution than single arterial phase gadoxetic-acid enhanced magnetic resonance imaging (MRI). Informed consent was waived for this retrospective study by our Institutional Review Board. In 752 consecutive patients who underwent gadoxetic acid-enhanced liver MRI, either single (n = 587) or triple (n = 165) arterial phases was obtained in a single breath-hold under MR fluoroscopy guidance. Arterial phase timing was assessed, and the degree of motion was rated on a four-point scale. The percentage of patients achieving the late arterial phase without significant motion was compared between the two methods using the χ{sup 2} test. The late arterial phase was captured at least once in 96.4% (159/165) of the triple arterial phase group and in 84.2% (494/587) of the single arterial phase group (p < 0.001). Significant motion artifacts (score ≤ 2) were observed in 13.3% (22/165), 1.2% (2/165), 4.8% (8/165) on 1st, 2nd, and 3rd scans of triple arterial phase acquisitions and 6.0% (35/587) of single phase acquisitions. Thus, the late arterial phase without significant motion artifacts was captured in 96.4% (159/165) of the triple arterial phase group and in 79.9% (469/587) of the single arterial phase group (p < 0.001). Triple arterial phase imaging may reliably provide adequate arterial phase imaging for gadoxetic acid-enhanced liver MRI.

  11. Triple arterial phase MR imaging with gadoxetic acid using a combination of contrast enhanced time robust angiography, keyhole, and viewsharing techniques and two-dimensional parallel imaging in comparison with conventional single arterial phase

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jeong Hee; Lee, Jeong Min; Han, Joon Koo [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Yu, Mi Hye [Dept. of Radiology, Konkuk University Medical Center, Seoul (Korea, Republic of); Kim, Eun Ju [Philips Healthcare Korea, Seoul (Korea, Republic of)

    2016-07-15

    To determine whether triple arterial phase acquisition via a combination of Contrast Enhanced Time Robust Angiography, keyhole, temporal viewsharing and parallel imaging can improve arterial phase acquisition with higher spatial resolution than single arterial phase gadoxetic-acid enhanced magnetic resonance imaging (MRI). Informed consent was waived for this retrospective study by our Institutional Review Board. In 752 consecutive patients who underwent gadoxetic acid-enhanced liver MRI, either single (n = 587) or triple (n = 165) arterial phases was obtained in a single breath-hold under MR fluoroscopy guidance. Arterial phase timing was assessed, and the degree of motion was rated on a four-point scale. The percentage of patients achieving the late arterial phase without significant motion was compared between the two methods using the χ2 test. The late arterial phase was captured at least once in 96.4% (159/165) of the triple arterial phase group and in 84.2% (494/587) of the single arterial phase group (p < 0.001). Significant motion artifacts (score ≤ 2) were observed in 13.3% (22/165), 1.2% (2/165), 4.8% (8/165) on 1st, 2nd, and 3rd scans of triple arterial phase acquisitions and 6.0% (35/587) of single phase acquisitions. Thus, the late arterial phase without significant motion artifacts was captured in 96.4% (159/165) of the triple arterial phase group and in 79.9% (469/587) of the single arterial phase group (p < 0.001). Triple arterial phase imaging may reliably provide adequate arterial phase imaging for gadoxetic acid-enhanced liver MRI.

  12. Three-dimensional SPECT [single photon emission computed tomography] reconstruction of combined cone beam and parallel beam data

    International Nuclear Information System (INIS)

    Jaszczak, R.J.; Jianying Li; Huili Wang; Coleman, R.E.

    1992-01-01

    Single photon emission computed tomography (SPECT) using cone beam (CB) collimation exhibits increased sensitivity compared with acquisition geometries using parallel (P) hole collimation. However, CB collimation has a smaller field-of-view which may result in truncated projections and image artifacts. A primary objective of this work is to investigate maximum likelihood-expectation maximization (ML-EM) methods to reconstruct simultaneously acquired parallel and cone beam (P and CB) SPECT data. Simultaneous P and CB acquisition can be performed with commercially available triple camera systems by using two cone-beam collimators and a single parallel-hole collimator. The loss in overall sensitivity (relative to the use of three CB collimators) is about 15 to 20%. The authors have developed three methods to combine P and CB data using modified ML-EM algorithms. (author)

  13. Effect of two doses of carbamylated allergoid extract of dust mite on nasal reactivity.

    Science.gov (United States)

    Scalone, G; Compalati, E; Bruno, M E; Mistrello, G

    2013-11-01

    Background and Objective. Single SLIT studies with native allergen extracts support a dose-response effect for clinical and immunological outcomes. Conversely for carbamylated allergoids this dose-response effects is less evident, likely because the threshold for efficacy is more easily reached through the enhanced bioavailability of the extract consequent to the selective chemical modification. Thus this pilot study investigates the dose-response effect on nasal specific reactivity and safety of two unusual doses of carbamylated allergoid in patients mono-sensitized to house dust mites. Methods. A prospective open randomized study involved 6-65 year-old Italian patients with clinically relevant sensitization to house dust mites and positive response to nasal provocation challenge. Monomeric carbamylated allergoid was delivered once daily at the dose of 1000 AU or 2000 AU from June to September 2009, during the lowest level of mites exposure. Primary outcomes were the change of the threshold of allergen concentration for a positive nasal provocation test (NPT) before and after the treatment and the product safety. Secondary outcome was the change  in the mean percentage fall of peak nasal inspiratory flow (PNIF) following nasal challenge. Results. Thirty-four patients were enrolled. Fifteen in group 1 and 14 in group 2 concluded the study. After 12 weeks all patients treated in group 1 and all but one in group 2 showed an increase in the threshold dose provoking a positive NPT. Those with no symptoms onset with the highest dose delivered were 80% in group 1 and 78.6% in group 2 (p=0.92). From first to second challenge, the mean percentage fall of PNIF  was reduced with no statistical difference between groups (p=0.95), and with no difference between the final mean percentage falls (p=0.65). No serious adverse reactions occurred and the frequency of events, all mild, was similar in the two groups. Conclusions. Twelve weeks of carbamylated sublingual allergoid

  14. Effect of single-dose albendazole and vitamin A supplementation on the iron status of pre-school children in Sichuan, China.

    Science.gov (United States)

    Chen, Ke; Xie, Hu Mina; Tian, Weizheng; Zheng, Xiaoling; Jiang, Alice C

    2016-04-01

    The aim of this study was to explore the effect of single-dose albendazole and vitamin A intervention on the anaemic status and Fe metabolism of pre-school children. This study was a randomised, placebo-controlled and double-blinded intervention trial. All eligible anaemic pre-school children were randomly divided into three groups: group 1 received no intervention, which served as the control group, group 2 received 400 mg single-dose albendazole administration and group 3 received a 60000 μg vitamin A capsule combined with 400 mg single-dose albendazole at the beginning of the study. The follow-up period was for 6 months. Anthropometry and biochemical index about Fe metabolism were measured before and after intervention. A total of 209 pre-school anaemic children were randomly divided into three intervention groups (sixty-four, sixty-two and sixty for groups 1, 2 and 3, respectively). The mean age of the children in the study was 4·4 (sd 0·7) years and 50·5 % of the children were female (94/186). After a follow-up period of 6 months, the levels of serum retinol, ferritin, transferrin receptor-ferritin index and body total Fe content of children in group 3 were significantly higher compared with children in groups 1 and 2 (PAlbendazole plus vitamin A administration showed more efficacy on the improvement of serum retinol and Fe metabolic status.

  15. Single and 2-week repeated intravenous dose toxicity studies of disodium mercaptoundecahydro-closo-dodecaborate in rats

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Fumio; Yabuuchi, Kazuya; Ohno, Kouji; Muraoka, Yoshihiro [Shionogi and Co. Ltd., Toyonaka, Osaka (Japan). Developmental Research Lab.; Ikeuchi, Isao

    1998-10-01

    Disodium mercaptoundecahydro-closo-dodecaborate (BSH) is a boron compound used in Boron Neutron Capture Therapy for malignant brain tumors. Intravenous single and 2-week repeated dose toxicity studies of BSH were performed in Sprague-Dawley rats. In the single-dose study, BSH was administered at doses of 100, 300 or 600 mg/kg. Death occurred within 10 min (acute type) or from 5 hr to 2 days (delayed type) after dosing in the 600 mg/kg group. No differences in mortality by sex and dosing speed were observed. Major causes of death were considered to be circulatory disorder in acute death and renal injury in delayed death. The renal injury was observed in the 300 and 600 mg/kg groups. In the 2-week repeated dose study, BSH was administered at doses of 30, 100 or 300 mg/kg/day for 14 days. Body weight gain was suppressed in the 100 and 300 mg/kg groups. One male in the 300 mg/kg group died due to renal and pulmonary lesions at day 8. Slight anemia was observed in the 300 mg/kg group. Pathologically, the kidney showed tubular regeneration with increase of weight in the 300 mg/kg. From these results, the NOAEL of BSH is 30 mg/kg/day. (author)

  16. Persistence of immunity from 1 year of age after one or two doses of hepatitis A vaccine given to children in Argentina

    Directory of Open Access Journals (Sweden)

    Espul C

    2012-08-01

    Full Text Available Carlos Espul,1 Laura Benedetti,2 Héctor Cuello,3 Guy Houillon,4 Anvar Rasuli41Programa de Lucha Contra las Hepatitis Virales, Ministerio de Salud/Hospital Central de Mendoza, 2Programa Provincial de Inmunizaciones, Ministerio de Salud, 3Laboratorio de Virología, Hospital Central de Mendoza, Mendoza, Argentina; 4Sanofi Pasteur, Lyon, FranceBackground: This study was done to determine the immunogenicity of a single dose of hepatitis A vaccine in children, providing needed clinical data on the flexibility of booster administration.Methods: Participants had received one dose of inactivated hepatitis A vaccine (Avaxim™ 80 U Pediatric at 12–23 months of age or two doses of the same vaccine at 12 and 18 months of age prior to enrolment. Anti-hepatitis A antibody concentrations were measured at the first, second, and third year after vaccination. Suspected cases of hepatitis A in participant families were assessed and family socioeconomic data were collected.Results: A series of 546 participants were enrolled. Of 467 (85.5% participants completing 3 years of follow-up, 365 had received a single vaccine dose and 94 had received two vaccine doses. Seropositivity (anti-HAV ≥ 10 mIU/mL at 3 years was 99.7% after one dose and 100% after two doses. At one year, geometric mean concentrations were higher after two doses (1433.9 mIU/mL, 95% confidence interval [CI] 1108–1855 than one (209.7 mIU/mL, 95% CI 190.6–230.6. Geometric mean concentrations decreased in both groups during the study, but remained well above 10 mIU/mL through the third year. The geometric mean of 3-year to one-year anti-hepatitis A concentration ratios was 0.74 (95% CI 0.70–0.79 following one dose and 0.57 (95% CI 0.47–0.70 following two doses. The greatest decrease in geometric mean concentrations occurred during the third year, ie, 21.2% in the one-dose group and 40.8% in the two-dose group. Six participants became seronegative during follow-up and responded strongly to a

  17. Evaluation of doses to staff involved in interventional cardiology in two Khartoum hospitals

    International Nuclear Information System (INIS)

    Bashir, M. K. A.

    2009-11-01

    In interventional cardiac procedures, staff operates near the patient in a non-uniformly scattered radiation field. Consequently, workers may receive, over a period of time, relatively high radiation doses. The measurement of individual doses to personnel becomes critical due to the use of protective devices and, as a consequence of the large number of methods proposed to assess the effective dose, In this study, staff doses were measured in two cardiac centers: Ahmed Gasim Hospital and Cardiac Center, Khartoum. The objective was to measure personal dose equivalent and accordingly estimate the effective dose which is received by staff in interventional cardiology. Measurements were performed using electronic personal dosimeters (EPDs) worn over lead apron during the examination and were read immediately following each examination. A total number of 40 radiation worker were monitored for a period of two weeks. The highest doses received by the cardiologist followed by nurses and then X-ray technicians. Staff received mean effective doses that ranged from 24 to 110 μSv estimated for four weeks. Recommendations on how to reduce staff doses in interventional cardiology are presented. (Author)

  18. Single and repeated dose pharmacokinetics of dexketoprofen trometamol in patients with impaired liver function.

    Science.gov (United States)

    Valles, J; Artigas, R; Bertolotti, M; Crea, A; Muller, F; Paredes, I; Capriati, A

    2006-06-01

    Dexketoprofen trometamol, a high water-soluble salt of the active enantiomer of rac-ketoprofen, is a nonsteroidal antiinflammatory drug (NSAID) used for pain relief. This study compared the pharmacokinetics of dexketoprofen in patients with impaired liver function and normal subjects following single and repeated oral dosing. Subjects with normal liver function (n = 6) and with Child-Pugh A (n = 7) or Child-Pugh B (n = 5) hepatic impairment scores completed this open-label and parallel study. They received 25 mg dexketoprofen (equivalent to 37 mg of its tromethamine salt) as a single (day 1) and a 3-day repeated dose (1 dose every 8 hours for a total of 10 doses). Dexketoprofen concentrations were determined in plasma and urine by reverse-phase high performance liquid chromatography (HPLC). Model-independent pharmacokinetic parameters were obtained. All subjects completed the study. No serious adverse events were recorded. Following the single dose, mean (+/- SEM) Cmax were 3027.7 +/- 429.3 ng/ml (healthy subjects), 2856.3 +/- 340.3 ng/ml (Child-Pugh A) and 1937.2 +/- 328.0 ng/ml (Child-Pugh B). Median tmax were 0.49 h (0.33-0.68) h, 0.50 h (0.33-0.67) h and 0.67 h (0.33-1.50) h. AUC0-x averaged 3778.0 +/- 439.0 ng.h/ml, 4890.4 +/- 539.1 ng.h/ml and 3985.0 +/- 712.0 ng.h/ml. Mean CL/F were 101.1 +/- 11.3 ml/h/kg, 73.3 +/- 9.9 ml/h/kg and 88.8 +/- 15.5 ml/h/kg and V/F averaged 0.192 +/- 0.018 l/kg, 0.162 +/- 0.006 l/kg and 0.214 +/- 0.044 l/kg. Following the repeated administration, similar results were obtained showing no drug accumulation. As related to the administered dose, median excretions of unchanged and conjugated dexketoprofen in urine were 2.1% and 67.1% in healthy subjects, 2.8% and 60.9% in Child-Pugh A subjects and 4.4% and 47.7% in Child-Pugh B volunteers. A trend towards a reduced urinary excretion of conjugated dexketoprofen in hepatic patients, more evident in the Child-Pugh B than in the Child-Pugh A groups, was observed when compared with healthy

  19. Pharmacodynamic effects of steady-state fingolimod on antibody response in healthy volunteers: a 4-week, randomized, placebo-controlled, parallel-group, multiple-dose study.

    Science.gov (United States)

    Boulton, Craig; Meiser, Karin; David, Olivier J; Schmouder, Robert

    2012-12-01

    Fingolimod, a first-in-class oral sphingosine 1-phosphate receptor (S1PR) modulator, is approved in many countries for relapsing-remitting multiple sclerosis, at a once-daily 0.5-mg dose. A reduction in peripheral lymphocyte count is an expected consequence of the fingolimod mechanism of S1PR modulation. The authors investigated if this pharmacodynamic effect impacts humoral and cellular immunogenicity. In this double-blind, parallel-group, 4-week study, 72 healthy volunteers were randomized to steady state, fingolimod 0.5 mg, 1.25 mg, or to placebo. The authors compared T-cell dependent and independent responses to the neoantigens, keyhole limpet hemocyanin (KLH), and pneumococcal polysaccharides vaccine (PPV-23), respectively, and additionally recall antigen response (tetanus toxoid [TT]) and delayed-type hypersensitivity (DTH) to KLH, TT, and Candida albicans. Fingolimod caused mild to moderate decreases in anti-KLH and anti-PPV-23 IgG and IgM levels versus placebo. Responder rates were identical between placebo and 0.5-mg groups for anti-KLH IgG (both > 90%) and comparable for anti-PPV-23 IgG (55% and 41%, respectively). Fingolimod did not affect anti-TT immunogenicity, and DTH response did not differ between placebo and fingolimod 0.5-mg groups. Expectedly, lymphocyte count reduced substantially in the fingolimod groups versus placebo but reversed by study end. Fingolimod was well tolerated, and the observed safety profile was consistent with previous reports.

  20. A double blind, randomised, parallel group study on the efficacy and safety of treating acute lateral ankle sprain with oral hydrolytic enzymes

    NARCIS (Netherlands)

    Kerkhoffs, G. M. M. J.; Struijs, P. A. A.; de Wit, C.; Rahlfs, V. W.; Zwipp, H.; van Dijk, C. N.

    2004-01-01

    Objective: To compare the effectiveness and safety of the triple combination Phlogenzym ( rutoside, bromelain, and trypsin) with double combinations, the single substances, and placebo. Design: Multinational, multicentre, double blind, randomised, parallel group design with eight groups structured

  1. Acoustic neuromas: single dose vs fractionated therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fuss, M; Debus, J; Lohr, F; Engenhart-Cabillic, R; Wannenmacher, M

    1997-07-01

    patients (18%) in the RS group, none of them requiring therapy, but none in the FT group. Hearing impairment improved in 1 case (RS) and 4 cases (FT). Complete hearing loss was diagnosed in 1 case in the FT group but in 3 cases in the RS group (all these patients were treated with 16 Gy or more). One temporary facial nerve weakness was found after FT. Among the RS group treated with {>=}16 Gy, 4 permanent facial nerve lesions were observed with complete facial nerve paresis in 2 patients. Improvement of vertigo or tinnitus was found in 1 patient after FT and in 3 patients treated with RS. If radiosurgical doses were <15 Gy, no severe side effects were observed. Among this group, 6 patients (54%) showed a significant reduction of preexisting neurological dysfunction. Conclusion: Radiosurgical treatment of small acoustic neuromas with doses <15 Gy prescribed to a volume <10 ccm results in excellent tumor control with no relevant toxicity. For fractionated therapy, results are comparable, even if the tumor volume exceeded 10 ccm. Single dose treatment with doses >15 Gy may cause higher toxicity. Fractionated conformal radiotherapy offers effective tumor control and low morbidity especially after contralateral neurosurgical resection of an acoustic neuroma with consecutive hearing loss and/or facial paresis.

  2. Vaxchora: A Single-Dose Oral Cholera Vaccine.

    Science.gov (United States)

    Cabrera, Adriana; Lepage, Jayne E; Sullivan, Karyn M; Seed, Sheila M

    2017-07-01

    To review trials evaluating the efficacy and safety of Vaxchora, a reformulated, single-dose, oral, lyophilized Vibrio cholerae CVD 103-HgR vaccine for the prevention of travel-related cholera caused by V cholerae serogroup O1. A literature search was conducted using MEDLINE (1946 to January week 3, 2017) and EMBASE (1996 to 2017 week 3). Keywords included oral cholera vaccine, single-dose, Vaxchora, and CVD 103-HgR. Limits included human, clinical trials published in English since 2010. ClinicalTrials.gov was used as a source for unpublished data. Additional data sources were obtained through bibliographic review of selected articles. Studies that addressed the safety and efficacy of Vaxchora, the reformulated, single-dose oral CVD 103-HgR cholera vaccine, were selected for analysis. Approval of Vaxchora, was based on efficacy of the vaccine in human trials demonstrating 90.3% protection among those challenged with V cholerae 10 days after vaccination and in immunogenicity studies with 90% systemic vibriocidal antibody conversion at 6 months after a single-dose of vaccine. Tolerability was acceptable, with the most common adverse effects reported to be fatigue, headache, and abdominal pain. Vaxchora is the only FDA-approved, single-dose oral vaccine for the prevention of cholera caused by V cholerae serogroup O1 in adult travelers from the United States going to cholera-affected areas. Safety and efficacy has not been established in children, immunocompromised persons, and pregnant or breastfeeding women or those living in cholera-endemic areas.

  3. Propofol for pediatric tracheal intubation with deep anesthesia during sevoflurane induction: dosing according to elapsed time for two age groups.

    Science.gov (United States)

    Politis, George D; Stemland, Christopher J; Balireddy, Ravi K; Brockhaus, Julie; Hughes, Kevin R; Goins, Matthew D; McMurry, Timothy L

    2014-02-01

    To determine, for two different age groups, the effect of duration of sevoflurane administration on the amount of propofol needed when performing tracheal intubation. Classic Dixon's Up-and-Down sequential method. University based operating rooms. 106 ASA physical status 1 and 2 patients aged one to 11 years. Patients were allocated to the 1-6 year (≥ 12 and age groups. Midazolam 0.5 mg/kg was given orally to the 1-6 year group, and all patients were induced with 8% dialed sevoflurane and 67% nitrous oxide (N2O), with N2O discontinued and sevoflurane dialed to 5% after one minute and 1.5 minutes for the younger and older age groups, respectively. Intravenous access was obtained and propofol was promptly administered. Propofol dose was determined according to age group and whether propofol was given 2-4, 4-6, or 6-8 minutes after the start of sevoflurane induction, with Dixon's Up and Down Method used separately for each specific age/time group. Tracheal intubation conditions one minute after propofol were evaluated. Isotonic regression determined propofol ED50 estimates for excellent tracheal intubation conditions, and linear regression determined the effect of propofol dose on change in systolic blood pressure (SBP). Estimated propofol ED50 doses for 1-6 year olds, with 95% confidence intervals (CIs), were 1.48 mg/kg (0.80, 2.03), 0.00 mg/kg (0.00, 0.38), and 0.07 mg/kg (0.00, 0.68) in the 2-4, 4-6, and 6-8 minute groups, respectively, with estimated differences between the 2-4 minute group versus the 4-6 and 6-8 minute groups being 1.47 mg/kg (95% CI = 1.04, 2.06) and 1.41 mg/kg (95% CI = 0.74, 2.04), respectively. Estimated propofol ED50 doses for 6-11 year olds, with 95% CIs, were 2.35 mg/kg (1.97, 2.45) and 2.33 mg/kg (1.59, 2.45) in the 2-4 and 4-6 minute groups, respectively. Diminutions in SBP at one minute and two minutes after propofol administration were dose dependent for children 1-6 years of age, decreasing 5.3% and 8.1% for each 1 mg/kg of propofol

  4. Single-fraction stereotactic radiotherapy: a dose-response analysis of arteriovenous malformation obliteration

    International Nuclear Information System (INIS)

    Touboul, Emmanuel; Al Halabi, Assem; Buffat, Laurent; Merienne, Louis; Huart, Judith; Schlienger, Michel; Lefkopoulos, Dimitrios; Mammar, Hamid; Missir, Odile; Meder, Jean-Francois; Laurent, Alex; Housset, Martin

    1998-01-01

    Purpose: Stereotactic radiotherapy delivered in a high-dose single fraction is an effective technique to obliterate intracranial arteriovenous malformations (AVM). To attempt to analyze the relationships between dose, volume, and obliteration rates, we studied a group of patients treated using single-isocenter treatment plans. Methods and Materials: From May 1986 to December 1989, 100 consecutive patients with angiographically proven AVM had stereotactic radiotherapy delivered as a high-dose single fraction using a single-isocenter technique. Distribution according to Spetzler-Martin grade was as follows: 79 grade 1-3, three grade 4, 0 grade 5, and 18 grade 6. The target volume was spheroid in 74 cases, ellipsoid in 11, and large and irregular in 15. The targeted volume of the nidus was estimated using two-dimensional stereotactic angiographic data and, calculated as an ovoid-shaped lesion, was 1900 ± 230 mm 3 (median 968 mm 3 ; range 62-11, 250 mm 3 ). The mean minimum target dose (D min ) was 19 ± 0.6 Gy (median 20 Gy; range: 3-31.5). The mean volume within the isodose which corresponded to the minimum target dose was 2500 ± 300 mm 3 (median 1200 mm 3 ; range 75-14 900 mm 3 ). The mean maximum dose (D max ) was 34.5 ± 0.5 Gy (median 35 Gy; range 15-45). The mean angiographic follow-up was 42 ± 2.3 months (median 37.5; range 7-117). Results: The absolute obliteration rate was 51%. The 5-year actuarial obliteration rate was 62.5 ± 7%. After univariate analysis, AVM obliteration was influenced by previous surgery (p = 0.0007), D min by steps of 5 Gy (p = 0.005), targeted volume of the nidus (≤968 mm 3 vs. >968 mm 3 ; p = 0.015), and grade according to Spetzler-Martin (grade 1-3 vs. grade 4-6; p = 0.011). After multivariate analysis, the independent factors influencing AVM obliteration were the D min [relative risk (RR) 1.9; 95% confidence interval (CI) 1.4-2.5; p min but does not seem to be influenced by D max and the targeted volume of the nidus

  5. Single-electron pulse-height spectra in thin-gap parallel-plate chambers

    CERN Document Server

    Fonte, Paulo J R; Peskov, Vladimir; Policarpo, Armando

    1999-01-01

    Single-electron pulse-height spectra were measured in 0.6 and 1.2 mm parallel-plate chambers developed for the TOF system of the ALICE /LHC-HI experiment. Mixtures of Ar with ethane, isobutane, and SF/sub 6/ were studied. The observed spectrum shows a clear peak for all gases, suggesting efficient single-electron detection in thin parallel-plate structures. The pulse-height spectrum can be described by the weighted sum of an exponential and a Polya distribution, the Polya contribution becoming more important at higher gains. Additionally, it was found that the maximum gain, above 10/sup 6/, is limited by the appearance of streamers and depends weakly on the gas composition. The suitability of each mixture for single-electron detection is also quantitatively assessed. (8 refs).

  6. Single toxin dose-response models revisited

    Energy Technology Data Exchange (ETDEWEB)

    Demidenko, Eugene, E-mail: eugened@dartmouth.edu [Department of Biomedical Data Science, Geisel School of Medicine at Dartmouth, Hanover, NH03756 (United States); Glaholt, SP, E-mail: sglaholt@indiana.edu [Indiana University, School of Public & Environmental Affairs, Bloomington, IN47405 (United States); Department of Biological Sciences, Dartmouth College, Hanover, NH03755 (United States); Kyker-Snowman, E, E-mail: ek2002@wildcats.unh.edu [Department of Natural Resources and the Environment, University of New Hampshire, Durham, NH03824 (United States); Shaw, JR, E-mail: joeshaw@indiana.edu [Indiana University, School of Public & Environmental Affairs, Bloomington, IN47405 (United States); Chen, CY, E-mail: Celia.Y.Chen@dartmouth.edu [Department of Biological Sciences, Dartmouth College, Hanover, NH03755 (United States)

    2017-01-01

    The goal of this paper is to offer a rigorous analysis of the sigmoid shape single toxin dose-response relationship. The toxin efficacy function is introduced and four special points, including maximum toxin efficacy and inflection points, on the dose-response curve are defined. The special points define three phases of the toxin effect on mortality: (1) toxin concentrations smaller than the first inflection point or (2) larger then the second inflection point imply low mortality rate, and (3) concentrations between the first and the second inflection points imply high mortality rate. Probabilistic interpretation and mathematical analysis for each of the four models, Hill, logit, probit, and Weibull is provided. Two general model extensions are introduced: (1) the multi-target hit model that accounts for the existence of several vital receptors affected by the toxin, and (2) model with a nonzero mortality at zero concentration to account for natural mortality. Special attention is given to statistical estimation in the framework of the generalized linear model with the binomial dependent variable as the mortality count in each experiment, contrary to the widespread nonlinear regression treating the mortality rate as continuous variable. The models are illustrated using standard EPA Daphnia acute (48 h) toxicity tests with mortality as a function of NiCl or CuSO{sub 4} toxin. - Highlights: • The paper offers a rigorous study of a sigmoid dose-response relationship. • The concentration with highest mortality rate is rigorously defined. • A table with four special points for five morality curves is presented. • Two new sigmoid dose-response models have been introduced. • The generalized linear model is advocated for estimation of sigmoid dose-response relationship.

  7. Marketing the academic medical center group practice.

    Science.gov (United States)

    Eudes, J A; Divis, K L

    1992-01-01

    From a marketing perspective, there are many differences between private and academic medical center (AMC) group practices. Given the growing competition between the two, write John Eudes and Kathy Divis, it is important for the AMC group practice to understand and use these differences to develop a competitive market advantage.

  8. PHARMACOKINETICS OF SINGLE-DOSE ORALLY ADMINISTERED CIPROFLOXACIN IN CALIFORNIA SEA LIONS (ZALOPHUS CALIFORNIANUS).

    Science.gov (United States)

    Barbosa, Lorraine; Johnson, Shawn P; Papich, Mark G; Gulland, Frances

    2015-06-01

    Ciprofloxacin is commonly selected for clinical use due to its broad-spectrum efficacy and is a frequently administered antibiotic at The Marine Mammal Center, a marine mammal rehabilitation facility. Ciprofloxacin is used for treatment of California sea lions ( Zalophus californianus ) suffering from a variety of bacterial infections at doses extrapolated from other mammalian species. However, as oral absorption is variable both within and across species, a more accurate determination of appropriate dosage is needed to ensure effective treatment and avoid emergence of drug-resistant bacterial strains. A pharmacokinetic study was performed to assess plasma concentrations of ciprofloxacin in California sea lions after a single oral dose. Twenty healthy California sea lions received a single 10-mg/kg oral dose of ciprofloxacin administered in a herring fish. Blood was then collected at two of the following times from each individual: 0.5, 0.75, 1, 2, 4, 8, 10, 12, 18, and 24 hr postingestion. Plasma ciprofloxacin concentration was assessed via high-performance liquid chromatography. A population pharmacokinetics model demonstrated that an oral ciprofloxacin dose of 10 mg/kg achieved an area under the concentration vs. time curve of 6.01 μg hr/ml. Absorption was rapid, with ciprofloxacin detectable in plasma 0.54 hr after drug administration; absorption half-life was 0.09 hr. A maximum plasma concentration of 1.21 μg/ml was observed at 1.01 hr, with an elimination half-life of 3.09 hr. Ciprofloxacin administered orally at 10 mg/kg produced therapeutic antibacterial exposure for only some of the most susceptible bacterial organisms commonly isolated from California sea lions.

  9. Spatial resolution of 2D ionization chamber arrays for IMRT dose verification: single-detector size and sampling step width

    International Nuclear Information System (INIS)

    Poppe, Bjoern; Djouguela, Armand; Blechschmidt, Arne; Willborn, Kay; Ruehmann, Antje; Harder, Dietrich

    2007-01-01

    The spatial resolution of 2D detector arrays equipped with ionization chambers or diodes, used for the dose verification of IMRT treatment plans, is limited by the size of the single detector and the centre-to-centre distance between the detectors. Optimization criteria with regard to these parameters have been developed by combining concepts of dosimetry and pattern analysis. The 2D-ARRAY Type 10024 (PTW-Freiburg, Germany), single-chamber cross section 5 x 5 mm 2 , centre-to-centre distance between chambers in each row and column 10 mm, served as an example. Additional frames of given dose distributions can be taken by shifting the whole array parallel or perpendicular to the MLC leaves by, e.g., 5 mm. The size of the single detector is characterized by its lateral response function, a trapezoid with 5 mm top width and 9 mm base width. Therefore, values measured with the 2D array are regarded as sample values from the convolution product of the accelerator generated dose distribution and this lateral response function. Consequently, the dose verification, e.g., by means of the gamma index, is performed by comparing the measured values of the 2D array with the values of the convolution product of the treatment planning system (TPS) calculated dose distribution and the single-detector lateral response function. Sufficiently small misalignments of the measured dose distributions in comparison with the calculated ones can be detected since the lateral response function is symmetric with respect to the centre of the chamber, and the change of dose gradients due to the convolution is sufficiently small. The sampling step width of the 2D array should provide a set of sample values representative of the sampled distribution, which is achieved if the highest spatial frequency contained in this function does not exceed the 'Nyquist frequency', one half of the sampling frequency. Since the convolution products of IMRT-typical dose distributions and the single

  10. A Novel Design of 4-Class BCI Using Two Binary Classifiers and Parallel Mental Tasks

    Directory of Open Access Journals (Sweden)

    Tao Geng

    2008-01-01

    Full Text Available A novel 4-class single-trial brain computer interface (BCI based on two (rather than four or more binary linear discriminant analysis (LDA classifiers is proposed, which is called a “parallel BCI.” Unlike other BCIs where mental tasks are executed and classified in a serial way one after another, the parallel BCI uses properly designed parallel mental tasks that are executed on both sides of the subject body simultaneously, which is the main novelty of the BCI paradigm used in our experiments. Each of the two binary classifiers only classifies the mental tasks executed on one side of the subject body, and the results of the two binary classifiers are combined to give the result of the 4-class BCI. Data was recorded in experiments with both real movement and motor imagery in 3 able-bodied subjects. Artifacts were not detected or removed. Offline analysis has shown that, in some subjects, the parallel BCI can generate a higher accuracy than a conventional 4-class BCI, although both of them have used the same feature selection and classification algorithms.

  11. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  12. Everolimus in clinical practice after liver transplantation: a single-center experience

    Directory of Open Access Journals (Sweden)

    O. A. Gerasimova

    2017-01-01

    Full Text Available Aim. Single-center analysis of everolimus treatment after liver transplantation. Materials and methods. 23 patients having received Certican after OLT in RSCRST were observed in period from 6 months to 5 years; comparison group consisted of 50 patients who received immunosuppressive scheme with tacrolimus. Conversion to everolimus was performed in the period from 1 month after OLT after discharge and at later time according to the indications: hepatocellular cancer, cumulative CNI nephrotoxicity, the development of malignancies, and intolerance to CNI. The concentrations of CNI and everolimus in the blood (target concentration of tacrolimus 1.5–2 ng/ml, everolimus 3–8 ng/ml were monitored. Glomerular filtration rate (GFR was determined using the CKD-EPI equation. Adverse events of everolimus were evaluated. Results. The immunosuppressive scheme with everolimus is presented; adverse events with dose-dependent hypercholesterolemia (34.7% as the main; the average level of blood cholesterol was not significantly different from that in the control group, 5.6 ± 0.9 vs 5.1 ± 1.4 mmol/l (Z = 1.3, p = 0.17. Renal function was stable throughout the observation period (35 ± 16 months. GFR (CKD-EPI before conversion was 75.8 ± 17.5 ml/min. 6 patients treated with Certican for 5 years had final GFR 96.6 ± 5.1 ml/min. GFR in the group of Certican at 12 months post conversion was 87.5 ± 16.3 ml/min vs 94.2 ± 16.8 ml/min (p = 0.08 in the control group. We revealed metastases to the liver and lungs in 5 patients from 13 patients with HCC, survival rate in this group depended on the compliance with the Milan criteria (Z = 2.4, p = 0.02. Conclusion. Everolimus allows maintaining of a stable renal function to prevent progression of renal failure; conversion should be initiated as early as possible. Combination of everolimus with reduced dose of CNI is optimal. Despite the fact that side effects are developing in most patients, adequate monitoring of

  13. Tolerance of the human spinal cord to single dose radiosurgery

    International Nuclear Information System (INIS)

    Ryu, S.; Zhu, G.; Yin, F.-F.; Ajlouni, M.; Kim, J.H.

    2003-01-01

    Tolerance of the spinal cord to the single dose of radiation is not well defined. Although there are cases of human spinal cord tolerance from re-irradiation to the same cord level, the information about the tolerance of human spinal cord to single large dose of radiosurgery is not available. We carried out spinal radiosurgery to treat spinal metastasis and studied the single dose tolerance of the human spinal cord in an ongoing dose escalation paradigm. A total of 39 patients with 48 lesions of spinal metastasis were treated with single dose radiosurgery at Henry Ford Hospital. The radiosurgery dose was escalated from 8 Gy to 16 Gy at 2 Gy increment. The radiation dose was prescribed to periphery of the spinal tumor. The radiation dose to the spinal cord was estimated by computerized dosimetry. The median follow-up time was 10 months (range 6-18 months) from the radiosurgery. The endpoint of the study was to demonstrate the efficacy of the spinal radiosurgery and to determine the tolerance of human spinal cord to single dose radiosurgery. The dose to the spinal cord was generally less than 50 % of the prescribed radiation dose. The volume of the spinal cord that received higher than this dose was less than 20 % of the anterior portion of the spinal cord. Maximum single dose of 8 Gy was delivered to the anterior 20 % of the spinal cord in this dose escalation study. The dose volume histogram will be presented. There was no acute or subacute radiation toxicity detected clinically and radiologically during the maximum follow-up of 20 months. Further dose escalation is in progress. The single tolerance dose of the human spinal cord appears to be at least 8 Gy when it was given to the 20 % of the cord volume, although the duration of follow up is not long enough to detect severe late cord toxicity. This study offers a valuable radiobiological basis of the normal spinal cord tolerance, and opens spinal radiosurgery as a safe treatment for spinal metastasis

  14. Functional and morphological changes in pig skin after single or fractionated doses in x rays

    International Nuclear Information System (INIS)

    Young, C.M.A.; Hopewell, J.W.

    1982-01-01

    The flank skin of pigs has been treated with either single or fractionated doses of x-irradiation. A single dose (2070 cGy) was compared with treatment given as 6 fractions in 18 days (6f/18 days; 3780 cGy) or 30 fractions in 39 days (30f/39 days; 8000 cGy). The doses were selected on the basis that similar levels of late tissue damage would result. Radiation induced changes in the skin were assessed by observing the skin reactions and by the measurement of isotope clearance (functional study), relative field contraction, dermal and epidermal thickness and dermal vascular density (morphological studies). In the three treatment groups the early radiation reaction varied considerably. In the first wave reaction (3 to 6 weeks after treatment) bright red erythema was recorded in many fields but moist desquamation developed only in the 30f/39 days treatment group. The second wave (10-16 weeks) was characterized by an ischemic mauve/dusky reaction. Dermal necrosis developed in 50% of the single dose fields. In the 30f/39 days regimen persistent moist desquamation progressed to dermal necrosis. Neither desquamation nor necrosis developed after 6f/18 days. Different levels of vascular damage in the dermis were assessed using an isotope clearance technique; for example in the early reaction significant changes were recorded in the papillary dermis (faster clearance) prior to the development of moist desquamation (30f/39 days) and in the reticular dermis (slower clearance) before necrosis (single dose). Changes in clearance rates have been correlated with changes in the vascular density and thickness of the dermis. Between 26 and 52 weeks (the late reaction) relative field contraction was slightly greater in the 30f/39 days group than in the other treatment groups

  15. Single Intramuscular-dose Toxicity of Water soluble Carthmi-Flos herbal acupuncture (WCF in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Lee Hyung-geol

    2014-03-01

    Full Text Available Objectives: This experiment was conducted to examine the toxicity of WCF (Water soluble Carthmi-Flos herbal acupuncture by administering a single intramuscular dose of WCF in 6-week-old, male and female Sprague-Dawley rats and to find the lethality dose for WCF. Methods: The experiment was conducted at Biotoxtech according to Good Laboratory Practices under a request by the Korean Pharmacopuncture Institute. This experiment was performed based on the testing standards of “Toxicity Test Standards for Drugs” by the Ministry of Food and Drug Safety. Subjects were divided into 4 groups: 1 control group in which normal saline was administered and 3 test groups in which 0.1, 0.5 or 1.0 mL of WCF was administered; a single intramuscular dose was injected into 5 males and 5 females in each group. General symptoms and body weights were observed/measured for 14 days after injection. At the end of the observation period, hematological and clinical chemistry tests were performed, followed by necropsy and histopathological examinations of the injected sections. Results: No mortalities were observed in any group. Also, symptoms, body weight, hematology, clinical chemistry and necropsy were not affected. However, histopathological examination of the injected part in one female in the 1.0-mL group showed infiltration of mononuclear cells and a multi-nucleated giant cell around eosinophilic material. Conclusion: Administration of single intramuscular doses of WCF in 3 groups of rats showed that the approximate lethal dose of WCF for all rats was in excess of 1.0 mL, as no mortalities were observed for injections up to and including 1.0 mL.

  16. Single-dose ceftriaxone for chancroid.

    Science.gov (United States)

    Bowmer, M I; Nsanze, H; D'Costa, L J; Dylewski, J; Fransen, L; Piot, P; Ronald, A R

    1987-01-01

    Men with genital ulcers that were culture positive for Haemophilus ducreyi were treated with intramuscular ceftriaxone and randomized to three different dose regimens. All but 1 of 50 men treated with 1 g of intramuscular ceftriaxone were cured. Similarly, 0.5 and 0.25 g cured 43 of 44 men and 37 of 38 men, respectively. A single dose of 250 mg of intramuscular ceftriaxone is an effective treatment for chancroid. PMID:3566241

  17. Evaluation of a liver micronucleus assay in young rats (IV): a study using a double-dosing/single-sampling method by the Collaborative Study Group for the Micronucleus Test (CSGMT)/Japanese Environmental Mutagen Society (JEMS)-Mammalian Mutagenicity Study Group (MMS).

    Science.gov (United States)

    Takasawa, Hironao; Suzuki, Hiroshi; Ogawa, Izumi; Shimada, Yasushi; Kobayashi, Kazuo; Terashima, Yukari; Matsumoto, Hirotaka; Oshida, Keiyu; Ohta, Ryo; Imamura, Tadashi; Miyazaki, Atsushi; Kawabata, Masayoshi; Minowa, Shigenori; Maeda, Akihisa; Hayashi, Makoto

    2010-04-30

    A collaborative study was conducted to evaluate whether a liver micronucleus assay using four-week-old male F344 rats can be used to detect genotoxic rat hepatocarcinogens using double-dosing with a single-sampling 4 days after the second dose. The assay methods were thoroughly validated by the seven laboratories involved in the study. Seven chemicals, 2,4-diaminotoluene, diethyl nitrosamine, p-dimethylaminoazobenzene, 1,2-dimethylhydrazine dihydrochloride, 2,4-dinitrotolunene, 2,6-dinitrotoluene and mitomycin C, known to produce positive responses in the single-dosing/triple-sampling method were selected for use in the present study, and each chemical was examined in two laboratories with the exception of 2,4-dinitrotolunene. Although several of the compounds were examined at lower doses for reasons of toxicity than in the single-dosing/triple-sampling method, all chemicals tested in the present study induced micronuclei in liver cells indicating a positive result. These findings suggest that the liver micronucleus assay can be used in young rats to detect genotoxic rat hepatocarcinogens using a double-dosing/single-sampling procedure. Further, the number of animals used in the liver micronucleus assay can be reduced by one-third to a half by using the double-dosing/single-sampling method. This reduction in animal numbers also has significant savings in time and resource for liver perfusion and hepatocyte isolation. Copyright 2010 Elsevier B.V. All rights reserved.

  18. A Parallel Approach for Frequent Subgraph Mining in a Single Large Graph Using Spark

    Directory of Open Access Journals (Sweden)

    Fengcai Qiao

    2018-02-01

    Full Text Available Frequent subgraph mining (FSM plays an important role in graph mining, attracting a great deal of attention in many areas, such as bioinformatics, web data mining and social networks. In this paper, we propose SSiGraM (Spark based Single Graph Mining, a Spark based parallel frequent subgraph mining algorithm in a single large graph. Aiming to approach the two computational challenges of FSM, we conduct the subgraph extension and support evaluation parallel across all the distributed cluster worker nodes. In addition, we also employ a heuristic search strategy and three novel optimizations: load balancing, pre-search pruning and top-down pruning in the support evaluation process, which significantly improve the performance. Extensive experiments with four different real-world datasets demonstrate that the proposed algorithm outperforms the existing GraMi (Graph Mining algorithm by an order of magnitude for all datasets and can work with a lower support threshold.

  19. Randomized, parallel-group, double-blind, controlled study to evaluate the efficacy and safety of carbohydrate-derived fulvic acid in topical treatment of eczema

    Directory of Open Access Journals (Sweden)

    Gandy JJ

    2011-09-01

    Full Text Available Justin J Gandy, Jacques R Snyman, Constance EJ van RensburgDepartment of Pharmacology, Faculty of Health Sciences, University of Pretoria, Pretoria, South AfricaBackground: The purpose of this study was to evaluate the efficacy and safety of carbohydrate-derived fulvic acid (CHD-FA in the treatment of eczema in patients two years and older.Methods: In this single-center, double-blind, placebo-controlled, parallel-group comparative study, 36 volunteers with predetermined eczema were randomly assigned to receive either the study drug or placebo twice daily for four weeks.Results: All safety parameters remained within normal limits, with no significant differences in either group. Significant differences were observed for both severity and erythema in the placebo and CHD-FA treated groups, and a significant difference was observed for scaling in the placebo-treated group. With regard to the investigator assessment of global response to treatment, a significant improvement was observed in the CHD-FA group when compared with the placebo group. A statistically significant decrease in visual analog scale score was observed in both groups, when comparing the baseline with the final results.Conclusion: CHD-FA was well tolerated, with no difference in reported side effects other than a short-lived burning sensation on application. CHD-FA significantly improved some aspects of eczema. Investigator assessment of global response to treatment with CHD-FA was significantly better than that with emollient therapy alone. The results of this small exploratory study suggest that CHD-FA warrants further investigation in the treatment of eczema.Keywords: fulvic acid, eczema, anti-inflammatory, efficacy, safety

  20. Budesonide/formoterol as effective as prednisolone plus formoterol in acute exacerbations of COPD A double-blind, randomised, non-inferiority, parallel-group, multicentre study

    Directory of Open Access Journals (Sweden)

    Andersson Eva

    2009-02-01

    Full Text Available Abstract Background Oral corticosteroids and inhaled bronchodilators with or without antibiotics represent standard treatment of COPD exacerbations of moderate severity. Frequent courses of oral steroids may be a safety issue. We wanted to evaluate in an out-patient setting whether a 2-week course of inhaled budesonide/formoterol would be equally effective for treatment of acute COPD exacerbations as standard therapy in patients judged by the investigator not to require hospitalisation. Methods This was a double-blind, randomised, non-inferiority, parallel-group, multicentre study comparing two treatment strategies; two weeks' treatment with inhaled budesonide/formoterol (320/9 μg, qid was compared with prednisolone (30 mg once daily plus inhaled formoterol (9 μg bid in patients with acute exacerbations of COPD attending a primary health care centre. Inclusion criteria were progressive dyspnoea for less than one week, FEV1 30–60% of predicted normal after acute treatment with a single dose of oral corticosteroid plus nebulised salbutamol/ipratropium bromide and no requirement for subsequent immediate hospitalisation, i.e the clinical status after the acute treatment allowed for sending the patient home. A total of 109 patients (mean age 67 years, 33 pack-years, mean FEV1 45% of predicted were randomized to two weeks' double-blind treatment with budesonide/formoterol or prednisolone plus formoterol and subsequent open-label budesonide/formoterol (320/9 μg bid for another 12 weeks. Change in FEV1 was the primary efficacy variable. Non-inferiority was predefined. Results Non-inferiority of budesonide/formoterol was proven because the lower limit of FEV1-change (97.5% CI was above 90% of the efficacy of the alternative treatment. Symptoms, quality of life, treatment failures, need for reliever medication (and exacerbations during follow-up did not differ between the groups. No safety concerns were identified. Conclusion High dose budesonide

  1. Pharmacokinetic comparison of acetaminophen elixir versus suppositories in vaccinated infants (aged 3 to 36 months): a single-dose, open-label, randomized, parallel-group design.

    Science.gov (United States)

    Walson, Philip D; Halvorsen, Mark; Edge, James; Casavant, Marcel J; Kelley, Michael T

    2013-02-01

    Because of practical problems and ethical concerns, few studies of the pharmacokinetics (PK) of acetaminophen (ACET) in infants have been published. The goal of this study was to compare the PK of an ACET rectal suppository with a commercially available ACET elixir to complete a regulatory obligation to market the suppository. This study was not submitted previously because of numerous obstacles related to both the investigators and the commercial entities associated with the tested product. Thirty infants (age 3-36 months) prescribed ACET for either fever, pain, or postimmunization prophylaxis of fever and discomfort were randomized to receive a single 10- to 15-mg/kg ACET dose either as the rectal suppository or oral elixir. Blood was collected at selected times for up to 8 hours after administration. ACET concentrations were measured by using a validated HPLC method, and PK behavior and bioavailability were compared for the 2 preparations. All 30 infants enrolled were prescribed ACET for postimmunization prophylaxis. PK samples were available in 27 of the 30 enrolled infants. Subject enrollment (completed in January 1995) was rapid (8.3 months) and drawn entirely from a vaccinated infant clinic population. There were no statistically significant differences between the subjects (elixir, n = 12; suppository, n = 15) in either mean (SD) age (10.0 [6.3] vs 12.4 [8.1] months), weight (8.6 [2.3] vs 9.4 [2.4] kg), sex (7 of 12 males vs 7 of 15 males), or racial distribution (5 white, 5 black, and 2 biracial vs 4 white and 11 black) between the 2 dosing groups (oral vs rectal, respectively). The oral and rectal preparations produced similar, rapid peak concentrations (T(max), 1.16 vs 1.17 hours; P = 0.98) and elimination t(½) (1.84 vs 2.10 hours; P = 0.14), respectively. No statistically significant differences were found between either C(max) (7.65 vs 5.68 μg/mL) or total drug exposure (AUC(0-∞), 23.36 vs 20.45 μg-h/mL) for the oral versus rectal preparations

  2. Measurement of the equivalent dose in quartz using a regenerative-dose single-aliquot protocol

    International Nuclear Information System (INIS)

    Murray, A.S.; Roberts, R.G.

    1998-01-01

    The principles behind a regenerative-dose single-aliquot protocol are outlined. It is shown for three laboratory-bleached Australian sedimentary quartz samples that the relative change in sensitivity of the optically stimulated luminescence (OSL) during a repeated measurement cycle (consisting of a dose followed by a 10 s preheat at a given temperature and then a 100 s exposure to blue/green light at 125 deg. C) is very similar to that of the 110 deg. C thermoluminescence (TL) peak measured during the preheat cycle. The absolute change in the TL sensitivity with preheat temperature is different for samples containing a natural or a regenerative dose. Furthermore, the absolute change in sensitivity in both the OSL and TL signals is non-linear with regeneration cycle, but the relative change in the OSL signal compared to the following 110 deg. C TL measurement is well approximated by a straight line. Both signals are thought to use the same luminescence centres, and so some common behaviour is not unexpected. A new regenerative-dose protocol is presented which makes use of this linear relationship to correct for sensitivity changes with regeneration cycle, and requires only one aliquot for the estimation of the equivalent dose (D e ). The protocol has been applied to quartz from nine Australian sites. To illustrate the value of the regenerative-dose single-aliquot approach, the apparent values of D e for 13 samples, containing doses of between 0.01 and 100 Gy, have been measured at various preheat temperatures of between 160 and 300 deg. C, using a single aliquot for each D e measurement. Excellent agreement is found between these single-aliquot estimates of D e and those obtained from additive-dose multiple-aliquot and single-aliquot protocols, over the entire dose range

  3. Massively parallel whole genome amplification for single-cell sequencing using droplet microfluidics.

    Science.gov (United States)

    Hosokawa, Masahito; Nishikawa, Yohei; Kogawa, Masato; Takeyama, Haruko

    2017-07-12

    Massively parallel single-cell genome sequencing is required to further understand genetic diversities in complex biological systems. Whole genome amplification (WGA) is the first step for single-cell sequencing, but its throughput and accuracy are insufficient in conventional reaction platforms. Here, we introduce single droplet multiple displacement amplification (sd-MDA), a method that enables massively parallel amplification of single cell genomes while maintaining sequence accuracy and specificity. Tens of thousands of single cells are compartmentalized in millions of picoliter droplets and then subjected to lysis and WGA by passive droplet fusion in microfluidic channels. Because single cells are isolated in compartments, their genomes are amplified to saturation without contamination. This enables the high-throughput acquisition of contamination-free and cell specific sequence reads from single cells (21,000 single-cells/h), resulting in enhancement of the sequence data quality compared to conventional methods. This method allowed WGA of both single bacterial cells and human cancer cells. The obtained sequencing coverage rivals those of conventional techniques with superior sequence quality. In addition, we also demonstrate de novo assembly of uncultured soil bacteria and obtain draft genomes from single cell sequencing. This sd-MDA is promising for flexible and scalable use in single-cell sequencing.

  4. A single-aliquot OSL protocol using bracketing regenerative doses to accurately determine equivalent doses in quartz

    CERN Document Server

    Folz, E

    1999-01-01

    In most cases, sediments show inherent heterogeneity in their luminescence behaviours and bleaching histories, and identical aliquots are not available: single-aliquot determination of the equivalent dose (ED) is then the approach of choice and the advantages of using regenerative protocols are outlined. Experiments on five laboratory bleached and dosed quartz samples, following the protocol described by Murray and Roberts (1998. Measurement of the equivalent dose in quartz using a regenerative-dose single aliquot protocol. Radiation Measurements 27, 171-184), showed the hazards of using a single regeneration dose: a 10% variation in the regenerative dose yielded some equivalent dose estimates that differed from the expected value by more than 5%. A protocol is proposed that allows the use of different regenerative doses to bracket the estimated equivalent dose. The measured ED is found to be in excellent agreement with the known value when the main regeneration dose is within 10% of the true equivalent dose.

  5. A single-aliquot OSL protocol using bracketing regenerative doses to accurately determine equivalent doses in quartz

    International Nuclear Information System (INIS)

    Folz, Elise; Mercier, Norbert

    1999-01-01

    In most cases, sediments show inherent heterogeneity in their luminescence behaviours and bleaching histories, and identical aliquots are not available: single-aliquot determination of the equivalent dose (ED) is then the approach of choice and the advantages of using regenerative protocols are outlined. Experiments on five laboratory bleached and dosed quartz samples, following the protocol described by Murray and Roberts (1998. Measurement of the equivalent dose in quartz using a regenerative-dose single aliquot protocol. Radiation Measurements 27, 171-184), showed the hazards of using a single regeneration dose: a 10% variation in the regenerative dose yielded some equivalent dose estimates that differed from the expected value by more than 5%. A protocol is proposed that allows the use of different regenerative doses to bracket the estimated equivalent dose. The measured ED is found to be in excellent agreement with the known value when the main regeneration dose is within 10% of the true equivalent dose

  6. Volvulus without malposition--a single-center experience.

    Science.gov (United States)

    Kargl, Simon; Wagner, Oliver; Pumberger, Wolfgang

    2015-01-01

    This is a single-center case series about the rare condition of volvulus without malposition and/or malrotation (VWM) in preterm babies. We focus on diagnostic difficulties, and our results should help to distinguish VWM as a distinct entity different from classical volvulus and segmental volvulus. Medical chart review of infants with VWM from 2003-2012 was used. A total of 15 patients were identified. All of them had volvulus in the absence of intestinal malposition or other associated intestinal pathologies. All patients were born prematurely. Emergency laparotomy was necessary in all 15 patients. Two groups were identified. Group 1 includes four patients with typical signs of meconium obstruction of prematurity (MOP). Small bowel resection was only necessary in one of these four patients, all survived without residual intestinal lesions. Group 2 consists of 11 patients without signs of MOP-small bowel resection and temporary enterostomy were necessary in all these children. Four patients presented with pneumatosis intestinalis on the abdominal plain film, suggesting necrotizing enterocolitis. Although two infants died, the survivors showed complete recovery. VWM is a distinct disease of prematurity. When associated with MOP, VWM has a favorable outcome of treatment. In contrast, VWM occurring in the absence of signs of meconium obstruction requires small bowel resection. VWM primarily affects the top of the midgut (ileum). Because of absent malposition, presentation of VWM may be uncharacteristic. Pneumatosis intestinalis in advanced VWM may lead to diagnostic difficulties and a delay in treatment. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Surface applicators for high dose rate brachytherapy in AIDS-related kaposi's sarcoma

    International Nuclear Information System (INIS)

    Evans, Michael D.C.; Yassa, Mariam; Podgorsak, Ervin B.; Roman, Ted N.; Schreiner, L. John; Souhami, Luis

    1997-01-01

    Purpose: The development of commercially available surface applicators using high dose rate remote afterloading devices has enabled radiotherapy centers to treat selected superficial lesions using a remote afterloading brachytherapy unit. The dosimetric parameters of these applicators, the clinical implementation of this technique, and a review of the initial patient treatment regimes are presented. Methods and Materials: A set of six fixed-diameter (1, 2, and 3 cm), tungsten/steel surface applicators is available for use with a single stepping-source (Ir-192, 370 GBq) high dose rate afterloader. The source can be positioned either in a parallel or perpendicular orientation to the treatment plane at the center of a conical aperture that sits at an SSD of approximately 15 mm and is used with a 1-mm thick removable plastic cap. The surface dose rates, percent depth dose, and off-axis ratios were measured. A custom-built, ceiling-mounted immobilization device secures the applicator on the surface of the patient's lesion during treatment. Results: Between November 1994, and September 1996, 16 AIDS-related Kaposi's sarcoma patients having a total of 120 lesions have been treated with palliative intent. Treatment sites were distributed between the head and neck, extremity, and torso. Doses ranged from 8 to 20 Gy, with a median dose of 10 Gy delivered in a single fraction. Treatments were well tolerated with minimal skin reaction, except for patients with lesions treated to 20 Gy who developed moderate/severe desquamation. Conclusion: Radiotherapy centers equipped with a high dose rate remote afterloading unit may treat small selected surface lesions with commercially available surface applicators. These surface applicators must be used with a protective cap to eliminate electron contamination. The optimal surface dose appears to be either 10 or 15 Gy depending upon the height of the lesion

  8. Many-Objective Particle Swarm Optimization Using Two-Stage Strategy and Parallel Cell Coordinate System.

    Science.gov (United States)

    Hu, Wang; Yen, Gary G; Luo, Guangchun

    2017-06-01

    It is a daunting challenge to balance the convergence and diversity of an approximate Pareto front in a many-objective optimization evolutionary algorithm. A novel algorithm, named many-objective particle swarm optimization with the two-stage strategy and parallel cell coordinate system (PCCS), is proposed in this paper to improve the comprehensive performance in terms of the convergence and diversity. In the proposed two-stage strategy, the convergence and diversity are separately emphasized at different stages by a single-objective optimizer and a many-objective optimizer, respectively. A PCCS is exploited to manage the diversity, such as maintaining a diverse archive, identifying the dominance resistant solutions, and selecting the diversified solutions. In addition, a leader group is used for selecting the global best solutions to balance the exploitation and exploration of a population. The experimental results illustrate that the proposed algorithm outperforms six chosen state-of-the-art designs in terms of the inverted generational distance and hypervolume over the DTLZ test suite.

  9. Effects of single and split doses of cobalt-60 gamma rays and 14 MeV neutrons on mouse stem cell spermatogonia.

    Science.gov (United States)

    Hacker-Klom, U B; Köhnlein, W; Göhde, W

    2000-12-01

    The long-term effects of ionizing radiation on male gonads may be the result of damage to spermatogonial stem cells. Doses of 10 cGy to 15 Gy (60)Co gamma rays or 10 cGy to 7 Gy 14 MeV neutrons were given to NMRI mice as single or split doses separated by a 24-h interval. The ratios of haploid spermatids/2c cells and the coefficients of variation of DNA histogram peaks as measures of both the cytocidal and the clastogenic actions of radiation were analyzed by DNA flow cytometry after DAPI staining. The coefficient of variation is not only a statistical examination of the data but is also used here as a measure of residual damage to DNA (i.e. a biological dosimeter). Testicular histology was examined in parallel. At 70 days after irradiation, the relative biological effectiveness for neutrons at 50% survival of spermatogonial stem cells was 3.6 for single doses and 2.8 for split doses. The average coefficient of variation of unirradiated controls of elongated spermatids was doubled when stem cells were irradiated with single doses of approximately 14 Gy (60)Co gamma rays or 3 Gy neutrons and observed 70 days later. Split doses of (60)Co gamma rays were more effective than single doses, doubling DNA dispersion at 7 Gy. No fractionation effect was found with neutrons with coefficients of variation.

  10. Parallel processing of two-dimensional Sn transport calculations

    International Nuclear Information System (INIS)

    Uematsu, M.

    1997-01-01

    A parallel processing method for the two-dimensional S n transport code DOT3.5 has been developed to achieve a drastic reduction in computation time. In the proposed method, parallelization is achieved with angular domain decomposition and/or space domain decomposition. The calculational speed of parallel processing by angular domain decomposition is largely influenced by frequent communications between processing elements. To assess parallelization efficiency, sample problems with up to 32 x 32 spatial meshes were solved with a Sun workstation using the PVM message-passing library. As a result, parallel calculation using 16 processing elements, for example, was found to be nine times as fast as that with one processing element. As for parallel processing by geometry segmentation, the influence of processing element communications on computation time is small; however, discontinuity at the segment boundary degrades convergence speed. To accelerate the convergence, an alternate sweep of angular flux in conjunction with space domain decomposition and a two-step rescaling method consisting of segmentwise rescaling and ordinary pointwise rescaling have been developed. By applying the developed method, the number of iterations needed to obtain a converged flux solution was reduced by a factor of 2. As a result, parallel calculation using 16 processing elements was found to be 5.98 times as fast as the original DOT3.5 calculation

  11. A new method for solving the two-center problem with relativistic potentials

    International Nuclear Information System (INIS)

    Gareev, F.A.; Gizzatkulov, M.Ch.

    1977-01-01

    A method has been proposed for the solution of the two-center problem with realistic potentials. It consists of two steps: first, a separable approximation to the single particle potentials is made and then the two-center problem with these separable potentials is solved exactly. The only approximations are introduced at the first stage in a well controllable way. As an example, we have calculated the single-particle energies and wave functions in the field of two 16 O like the Woods-Saxon potentials as functions of their distance R

  12. Single-dose Toxicity of ShinYangHur Herbal Acupuncture

    Directory of Open Access Journals (Sweden)

    Eunhye Cha

    2015-06-01

    Full Text Available Objectives: This study was carried out to analyze the single-dose toxicity of ShinYangHur (SYH herbal acupuncture injected into the muscles of Sprague-Dawley (SD rats. Methods: The SYH herbal acupuncture was made in a clean room at the Korean Pharmacopuncture Institute (KPI, Korea-Good Manufacturing Practice, K-GMP. After the mixing process with sterile distilled water, the pH was controlled to between 7.0 and 7.5. Then, NaCl was added to make a 0.9% isotonic solution by using sterilized equipment. All experiments were conducted at Biotoxtech, an institution authorized to perform non clinical studies under the regulations of Good Laboratory Practice (GLP. SD rats were chosen for the pilot study. Doses of SYH herbal acupuncture, 0.25, 0.5, and 1.0 mL, were administered to the experimental groups, and a dose of normal saline solution, 1.0 mL, was administered to the control group. This study was conducted under the approval of the Institutional Animal Ethics Committee. Results: No deaths or abnormalities occurred in any of the four groups. No significant changes in weight, hematological parameters or clinical chemistry between the control group and the experimental groups were observed. To check for abnormalities in organs and tissues, we used microscopy was used to examine representative histological sections of each specified organ; the results showed no significant differences in any of the organs or tissues. Conclusion: The above outcomes suggest that treatment with SYH herbal acupuncture is relatively safe. Further studies on this subject are needed to yield more concrete evidence.

  13. Pharmacology of ayahuasca administered in two repeated doses.

    Science.gov (United States)

    Dos Santos, Rafael G; Grasa, Eva; Valle, Marta; Ballester, Maria Rosa; Bouso, José Carlos; Nomdedéu, Josep F; Homs, Rosa; Barbanoj, Manel J; Riba, Jordi

    2012-02-01

    Ayahuasca is an Amazonian tea containing the natural psychedelic 5-HT(2A/2C/1A) agonist N,N-dimethyltryptamine (DMT). It is used in ceremonial contexts for its visionary properties. The human pharmacology of ayahuasca has been well characterized following its administration in single doses. To evaluate the human pharmacology of ayahuasca in repeated doses and assess the potential occurrence of acute tolerance or sensitization. In a double-blind, crossover, placebo-controlled clinical trial, nine experienced psychedelic drug users received PO the two following treatment combinations at least 1 week apart: (a) a lactose placebo and then, 4 h later, an ayahuasca dose; and (b) two ayahuasca doses 4 h apart. All ayahuasca doses were freeze-dried Amazonian-sourced tea encapsulated to a standardized 0.75 mg DMT/kg bodyweight. Subjective, neurophysiological, cardiovascular, autonomic, neuroendocrine, and cell immunity measures were obtained before and at regular time intervals until 12 h after first dose administration. DMT plasma concentrations, scores in subjective and neurophysiological variables, and serum prolactin and cortisol were significantly higher after two consecutive doses. When effects were standardized by plasma DMT concentrations, no differences were observed for subjective, neurophysiological, autonomic, or immunological effects. However, we observed a trend to reduced systolic blood pressure and heart rate, and a significant decrease for growth hormone (GH) after the second ayahuasca dose. Whereas there was no clear-cut tolerance or sensitization in the psychological sphere or most physiological variables, a trend to lower cardiovascular activation was observed, together with significant tolerance to GH secretion.

  14. Computations on the massively parallel processor at the Goddard Space Flight Center

    Science.gov (United States)

    Strong, James P.

    1991-01-01

    Described are four significant algorithms implemented on the massively parallel processor (MPP) at the Goddard Space Flight Center. Two are in the area of image analysis. Of the other two, one is a mathematical simulation experiment and the other deals with the efficient transfer of data between distantly separated processors in the MPP array. The first algorithm presented is the automatic determination of elevations from stereo pairs. The second algorithm solves mathematical logistic equations capable of producing both ordered and chaotic (or random) solutions. This work can potentially lead to the simulation of artificial life processes. The third algorithm is the automatic segmentation of images into reasonable regions based on some similarity criterion, while the fourth is an implementation of a bitonic sort of data which significantly overcomes the nearest neighbor interconnection constraints on the MPP for transferring data between distant processors.

  15. Memory Retrieval Given Two Independent Cues: Cue Selection or Parallel Access?

    Science.gov (United States)

    Rickard, Timothy C.; Bajic, Daniel

    2004-01-01

    A basic but unresolved issue in the study of memory retrieval is whether multiple independent cues can be used concurrently (i.e., in parallel) to recall a single, common response. A number of empirical results, as well as potentially applicable theories, suggest that retrieval can proceed in parallel, though Rickard (1997) set forth a model that…

  16. Balancing Radiation and Contrast Media Dose in Single-Pass Abdominal Multidetector CT: Prospective Evaluation of Image Quality.

    Science.gov (United States)

    Camera, Luigi; Romano, Federica; Liccardo, Immacolata; Liuzzi, Raffaele; Imbriaco, Massimo; Mainenti, Pier Paolo; Pizzuti, Laura Micol; Segreto, Sabrina; Maurea, Simone; Brunetti, Arturo

    2015-11-01

    As both contrast and radiation dose affect the quality of CT images, a constant image quality in abdominal contrast-enhanced multidetector computed tomography (CE-MDCT) could be obtained balancing radiation and contrast media dose according to the age of the patients. Seventy-two (38 Men; 34 women; aged 20-83 years) patients underwent a single-pass abdominal CE-MDCT. Patients were divided into three different age groups: A (20-44 years); B (45-65 years); and C (>65 years). For each group, a different noise index (NI) and contrast media dose (370 mgI/mL) was selected as follows: A (NI, 15; 2.5 mL/kg), B (NI, 12.5; 2 mL/kg), and C (NI, 10; 1.5 mL/kg). Radiation exposure was reported as dose-length product (DLP) in mGy × cm. For quantitative analysis, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated for both the liver (L) and the abdominal aorta (A). Statistical analysis was performed with a one-way analysis of variance. Standard imaging criteria were used for qualitative analysis. Although peak hepatic enhancement was 152 ± 16, 128 ± 12, and 101 ± 14 Hounsfield units (P contrast media dose (mL) administered were 476 ± 147 and 155 ± 27 for group A, 926 ± 291 and 130 ± 16 for group B, and 1981 ± 451 and 106 ± 15 for group C, respectively (P contrast media dose administered to patients of different age. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  17. A Randomized Single Blind Parallel Group Study Comparing Monoherbal Formulation Containing Holarrhena antidysenterica Extract with Mesalamine in Chronic Ulcerative Colitis Patients

    Directory of Open Access Journals (Sweden)

    Sarika Johari

    2016-01-01

    Full Text Available Background: Incidences of side effects and relapses are very common in chronic ulcerative colitis patients after termination of the treatment. Aims and Objectives: This study aims to compare the treatment with monoherbal formulation of Holarrhena antidysenterica with Mesalamine in chronic ulcerative colitis patients with special emphasis to side effects and relapse. Settings and Design: Patients were enrolled from an Ayurveda Hospital and a private Hospital, Gujarat. The study was randomized, parallel group and single blind design. Materials and Methods: The protocol was approved by Institutional Human Research Ethics Committee of Anand Pharmacy College on 23rd Jan 2013. Three groups (n = 10 were treated with drug Mesalamine (Group I, monoherbal tablet (Group II and combination of both (Group III respectively. Baseline characteristics, factors affecting quality of life, chronicity of disease, signs and symptoms, body weight and laboratory investigations were recorded. Side effects and complications developed, if any were recorded during and after the study. Statistical Analysis Used: Results were expressed as mean ± SEM. Data was statistically evaluated using t-test, Wilcoxon test, Mann Whitney U test, Kruskal Wallis test and ANOVA, wherever applicable, using GraphPad Prism 6. Results: All the groups responded positively to the treatments. All the patients were positive for occult blood in stool which reversed significantly after treatment along with rise in hemoglobin. Patients treated with herbal tablets alone showed maximal reduction in abdominal pain, diarrhea, and bowel frequency and stool consistency scores than Mesalamine treated patients. Treatment with herbal tablet alone and in combination with Mesalamine significantly reduced the stool infection. Patients treated with herbal drug alone and in combination did not report any side effects, relapse or complications while 50% patients treated with Mesalamine exhibited the relapse with

  18. Establishing a group of endpoints in a parallel computer

    Science.gov (United States)

    Archer, Charles J.; Blocksome, Michael A.; Ratterman, Joseph D.; Smith, Brian E.; Xue, Hanhong

    2016-02-02

    A parallel computer executes a number of tasks, each task includes a number of endpoints and the endpoints are configured to support collective operations. In such a parallel computer, establishing a group of endpoints receiving a user specification of a set of endpoints included in a global collection of endpoints, where the user specification defines the set in accordance with a predefined virtual representation of the endpoints, the predefined virtual representation is a data structure setting forth an organization of tasks and endpoints included in the global collection of endpoints and the user specification defines the set of endpoints without a user specification of a particular endpoint; and defining a group of endpoints in dependence upon the predefined virtual representation of the endpoints and the user specification.

  19. Critical group doses arising from routine aquatic discharges of activity from the Heysham 2 nuclear power station

    International Nuclear Information System (INIS)

    Maul, P.R.

    1986-07-01

    An assessment of critical group doses arising from routine discharges of activity to sea from the Heysham 2 nuclear power station has been undertaken using the CODAR2 computer program. The largest critical group dose rate was calculated to be 50 μSv/y, about 80 per cent of which arose from the external exposure of individuals occupying intertidal sediments of the Lune Estuary from the single nuclide 60 Co. CODAR2 employs a single well mixed local compartment for critical group calculations and can not include the effects of processes varying over the compartment. A more detailed study of the critical group exposure has been carried out using recently developed methods to assess the uncertainties and pessimisms involved in the CODAR2 calculations. It is concluded that these calculations are pessimistic by about a factor of 2, with a reference calculation using the more detailed methods giving a dose rate of 23 μSv/y for the Lune Estuary group. Further reductions in the dose estimate might be possible if site specific measurements of the concentration factor for Co on estuarine sediments and the sedimentation rate in the Lune Estuary could be made. (author)

  20. Pediatric bowel MRI - accelerated parallel imaging in a single breathhold

    International Nuclear Information System (INIS)

    Hohl, C.; Honnef, D.; Krombach, G.; Muehlenbruch, G.; Guenther, R.W.; Niendorf, T.; Ocklenburg, C.; Wenzl, T.G.

    2008-01-01

    Purpose: to compare highly accelerated parallel MRI of the bowel with conventional balanced FFE sequences in children with inflammatory bowel disease (IBD). Materials and methods: 20 children with suspected or proven IBD underwent MRI using a 1.5 T scanner after oral administration of 700-1000 ml of a Mannitol solution and an additional enema. The examination started with a 4-channel receiver coil and a conventional balanced FFE sequence in axial (2.5 s/slice) and coronal (4.7 s/slice) planes. Afterwards highly accelerated (R = 5) balanced FFE sequences in axial (0.5 s/slice) and coronal (0.9 s/slice) were performed using a 32-channel receiver coil and parallel imaging (SENSE). Both receiver coils achieved a resolution of 0.88 x 0.88 mm with a slice thickness of 5 mm (coronal) and 6 mm (axial) respectively. Using the conventional imaging technique, 4 - 8 breathholds were needed to cover the whole abdomen, while parallel imaging shortened the acquisition time down to a single breathhold. Two blinded radiologists did a consensus reading of the images regarding pathological findings, image quality, susceptibility to artifacts and bowel distension. The results for both coil systems were compared using the kappa-(κ)-coefficient, differences in the susceptibility to artifacts were checked with the Wilcoxon signed rank test. Statistical significance was assumed for p = 0.05. Results: 13 of the 20 children had inflammatory bowel wall changes at the time of the examination, which could be correctly diagnosed with both coil systems in 12 of 13 cases (92%). The comparison of both coil systems showed a good agreement for pathological findings (κ = 0.74 - 1.0) and the image quality. Using parallel imaging significantly more artifacts could be observed (κ = 0.47)

  1. Comparative efficacy of one versus two doses of praziquantel on cure rate of Schistosoma mansoni infection and re-infection in Mayuge District, Uganda

    DEFF Research Database (Denmark)

    Tukahebwa, Edridah M.; Vennervald, Birgitte J; Nuwaha, Fred

    2013-01-01

    BACKGROUND: The current recommended control strategy for schistosomiasis is annual treatment using 40 mg/kg of praziquantel. However, praziquantel is only effective on adult worms and giving a second dose may increase its efficacy. We assessed the effect of one versus two doses of praziquantel...... on cure rate and re-infection with Schistosoma mansoni in a high endemic community along Lake Victoria, Uganda. METHODOLOGY: To investigate the effect of the two regimens, 395 infected people were randomised into two groups; one received a single standard dose of praziquantel (Distocide® 600 mg, Shin...... Poong Pharmaceuticals, Seoul, Republic of Korea), 40mg/kg body weight, while the other group received a second dose 2 weeks later. Cure rate and infection intensity were assessed 9 weeks after the first treatment using standard parasitological procedures. Re-infection levels were monitored 8 and 24...

  2. Astigmatic single photon emission computed tomography imaging with a displaced center of rotation

    International Nuclear Information System (INIS)

    Wang, H.; Smith, M.F.; Stone, C.D.; Jaszczak, R.J.

    1998-01-01

    A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that is perpendicular to this axis. Using SPECT simulations of projection data from a hot rod phantom and point source arrays, it is found that a lack of incorporation of the mechanical shift in the reconstruction algorithm causes errors and artifacts in reconstructed SPECT images. The collimator and acquisition parameters in the astigmatic reconstruction formula, which include focal lengths, radius of rotation, and mechanical shifts, are often partly unknown and can be determined using the projections of a point source at various projection angles. The accurate determination of these parameters by a least squares fitting technique using projection data from numerically simulated SPECT acquisitions is studied. These studies show that the accuracy of parameter determination is improved as the distance between the point source and the axis of rotation of the gamma camera is increased. The focal length to the focal line perpendicular to the axis of rotation is determined more accurately than the focal length to the focal line parallel to this axis. copyright 1998 American Association of Physicists in Medicine

  3. Dose control in semi industrial irradiation plant at the Ezeiza Atomic Center

    International Nuclear Information System (INIS)

    Dorda, E.M.

    1987-01-01

    In 1975 a study was initiated at the Division of Dosimetry to develop a technique and a system of dosimetry to be applied to the radiosterilization processes in the semi industrial irradiation plant of Ezeiza Atomic Center. The result of this study was the potassium nitrate/nitrite dosimeter used as routine dosimeter for control processes in food conservation, with a dose range of 0.2 kGy-1 kGy and in radiosterilization processes of disposable medical products of 1 kGy-150kGy. The potassium nitrate crystals undergo a radiolytic reduction. A linear correlation between the dose applied to the solid and the production of potassium nitrite was observed. After the irradiation of solid, the produced nitrite solution is colorimetrically titrated by measuring the absorbency in a spectrophotometer at 504 nm. The color is due to the formation of a diazonium salt and its later copulation with N-1 naphtylethylendiamine hydrochloride in acid medium. In 1980 a postal survey was organized presenting this dosimeter to standardize the irradiation dose in industrial process for Latin America. This dosimeter was presented in 1984 at the International Symposium on High Doses of the IAEA that took place in Vienna. Since them, comparative studies were performed between this dosimeter and those internationally considered and accepted: cerium(IV)/cerium(III) sulphate, ionization chamber of parallel plates, alanine. The results of comparison with the alanine dosimeter, which was used by Dr. Regula of the GSF of Munich, were the following: February 1985: 0% deviation; February 1986: 0.43% deviation. (Author)

  4. Incorporating single-side sparing in models for predicting parotid dose sparing in head and neck IMRT

    International Nuclear Information System (INIS)

    Yuan, Lulin; Wu, Q. Jackie; Yin, Fang-Fang; Yoo, David; Jiang, Yuliang; Ge, Yaorong

    2014-01-01

    Purpose: Sparing of single-side parotid gland is a common practice in head-and-neck (HN) intensity modulated radiation therapy (IMRT) planning. It is a special case of dose sparing tradeoff between different organs-at-risk. The authors describe an improved mathematical model for predicting achievable dose sparing in parotid glands in HN IMRT planning that incorporates single-side sparing considerations based on patient anatomy and learning from prior plan data. Methods: Among 68 HN cases analyzed retrospectively, 35 cases had physician prescribed single-side parotid sparing preferences. The single-side sparing model was trained with cases which had single-side sparing preferences, while the standard model was trained with the remainder of cases. A receiver operating characteristics (ROC) analysis was performed to determine the best criterion that separates the two case groups using the physician's single-side sparing prescription as ground truth. The final predictive model (combined model) takes into account the single-side sparing by switching between the standard and single-side sparing models according to the single-side sparing criterion. The models were tested with 20 additional cases. The significance of the improvement of prediction accuracy by the combined model over the standard model was evaluated using the Wilcoxon rank-sum test. Results: Using the ROC analysis, the best single-side sparing criterion is (1) the predicted median dose of one parotid is higher than 24 Gy; and (2) that of the other is higher than 7 Gy. This criterion gives a true positive rate of 0.82 and a false positive rate of 0.19, respectively. For the bilateral sparing cases, the combined and the standard models performed equally well, with the median of the prediction errors for parotid median dose being 0.34 Gy by both models (p = 0.81). For the single-side sparing cases, the standard model overestimates the median dose by 7.8 Gy on average, while the predictions by the combined

  5. Efficacy of a radiation absorbing shield in reducing dose to the interventionalist during peripheral endovascular procedures: a single centre pilot study.

    Science.gov (United States)

    Power, S; Mirza, M; Thakorlal, A; Ganai, B; Gavagan, L D; Given, M F; Lee, M J

    2015-06-01

    This prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures. A commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated. TLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142). Initial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator's body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.

  6. Marrow toxicity of fractionated vs. single dose total body irradiation is identical in a canine model

    International Nuclear Information System (INIS)

    Storb, R.; Raff, R.F.; Graham, T.; Appelbaum, F.R.; Deeg, H.J.; Schuening, F.G.; Shulman, H.; Pepe, M.

    1993-01-01

    The authors explored in dogs the marrow toxicity of single dose total body irradiation delivered from two opposing 60 Co sources at a rate of 10 cGy/min and compared results to those seen with total body irradiation administered in 100 cGy fractions with minimum interfraction intervals of 6 hr. Dogs were not given marrow transplants. They found that 200 cGy single dose total body irradiation was sublethal, with 12 of 13 dogs showing hematopoietic recovery and survival. Seven of 21 dogs given 300 cGy single dose total body irradiation survived compared to 6 of 10 dogs given 300 cGy fractionated total body irradiation. One of 28 dogs given 400 cGy single dose total body irradiation survived compared to none of six given fractionated radiation. With granulocyte colony stimulating factor (GCSF) administered from day 0-21 after 400 cGy total body irradiation, most dogs survived with hematological recovery. Because of the almost uniform success with GCSF after 400 cGy single dose total body irradiation, a study of GCSF after 400 cGy fractionated total body irradiation was deemed not to be informative and, thus, not carried out. Additional comparisons between single dose and fractionated total body irradiation were carried out with GCSF administered after 500 and 600 cGy of total body irradiation. As with lower doses of total body irradiation, no significant survival differences were seen between the two modes of total body irradiation, and only 3 of 26 dogs studied survived with complete hematological recovery. Overall, therefore, survival among dogs given single dose total body irradiation was not different from that of dogs given fractionated total body irradiation (p = .67). Similarly, the slopes of the postirradiation declines of granulocyte and platelet counts and the rates of their recovery in surviving dogs given equal total doses of single versus fractionated total body irradiation were indistinguishable. 24 refs., 3 figs., 2 tabs

  7. Improved generation of single nitrogen-vacancy centers in diamond by ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Naydenov, Boris; Beck, Johannes; Steiner, Matthias; Balasubramanian, Gopalakrishnan; Jelezko, Fedor; Wrachtrup, Joerg [3. Institute of Physics, University of Stuttgart (Germany); Richter, Vladimir; Kalish, Rafi [Solid State Institute, Technion City, Haifa (Israel); Achard, Jocelyn [Laboratoire d' Ingenieurie des Materiaux et des Hautes Pressions, CNRS, Villetaneuse (France)

    2010-07-01

    Nitrogen-vacancy (NV) centers in diamond have recently attracted the attention of many research groups due to their possible application as quantum bits (qubits), ultra low magnetic field sensors and single photon sources. These color centers can be produced by nitrogen ion implantation, although the yield is usually below 5 % at low ion energies. Here we report an increase of the NV production efficiency by subsequently implanting carbon ions in the area of implanted nitrogen ions. This method improves the production yield by more than 50 %. We also show that very low nitrogen concentration (below 0.1 ppb) in diamond can be determined by converting the intrinsic nitrogen atoms to single NV centers and detecting the latter using a confocal microscope.

  8. Safety and Effectiveness of two treatment regimes with tranexamic acid to minimize inflammatory response in elective cardiopulmonary bypass patients: a randomized double-blind, dose-dependent, phase IV clinical trial

    Directory of Open Access Journals (Sweden)

    Martín Beatriz

    2011-10-01

    Full Text Available Abstract Background In cardiopulmonary bypass (CPB patients, fibrinolysis may enhance postoperative inflammatory response. We aimed to determine whether an additional postoperative dose of antifibrinolytic tranexamic acid (TA reduced CPB-mediated inflammatory response (IR. Methods We performed a randomized, double-blind, dose-dependent, parallel-groups study of elective CPB patients receiving TA. Patients were randomly assigned to either the single-dose group (40 mg/Kg TA before CPB and placebo after CPB or the double-dose group (40 mg/Kg TA before and after CPB. Results 160 patients were included, 80 in each group. The incident rate of IR was significantly lower in the double-dose-group TA2 (7.5% vs. 18.8% in the single-dose group TA1; P = 0.030. After adjusting for hypertension, total protamine dose and temperature after CPB, TA2 showed a lower risk of IR compared with TA1 [OR: 0.29 (95% CI: 0.10-0.83, (P = 0.013]. Relative risk for IR was 2.5 for TA1 (95% CI: 1.02 to 6.12. The double-dose group had significantly lower chest tube bleeding at 24 hours [671 (95% CI 549-793 vs. 826 (95% CI 704-949 mL; P = 0.01 corrected-P significant] and lower D-dimer levels at 24 hours [489 (95% CI 437-540 vs. 621(95% CI: 563-679 ng/mL; P = 0.01 corrected-P significant]. TA2 required lower levels of norepinephrine at 24 h [0.06 (95% CI: 0.03-0.09 vs. 0.20(95 CI: 0.05-0.35 after adjusting for dobutamine [F = 6.6; P = 0.014 corrected-P significant]. We found a significant direct relationship between IL-6 and temperature (rho = 0.26; P P P P P P P Conclusions Prolonged inhibition of fibrinolysis, using an additional postoperative dose of tranexamic acid reduces inflammatory response and postoperative bleeding (but not transfusion requirements in CPB patients. A question which remains unanswered is whether the dose used was ideal in terms of safety, but not in terms of effectiveness. Current Controlled Trials number ISRCTN: ISRCTN84413719

  9. A single pre-operative antibiotic dose is as effective as continued antibiotic prophylaxis in implant-based breast reconstruction: A matched cohort study.

    Science.gov (United States)

    Townley, William A; Baluch, Narges; Bagher, Shaghayegh; Maass, Saskia W M C; O'Neill, Anne; Zhong, Toni; Hofer, Stefan O P

    2015-05-01

    Infections following implant-based breast reconstruction can lead to devastating consequences. There is currently no consensus on the need for post-operative antibiotics in preventing immediate infection. This study compared two different methods of infection prevention in this group of patients. A retrospective matched cohort study was performed on consecutive women undergoing implant-based breast reconstruction at University Health Network, Toronto (November 2008-December 2012). All patients received a single pre-operative intravenous antibiotic dose. Group A received minimal interventions and Group B underwent maximal prophylactic measures. Patient (age, smoking, diabetes, co-morbidities), oncologic and procedural variables (timing and laterality) were collected. Univariate and multivariate logistic regression were performed to compare outcomes between the two groups. Two hundred and eight patients underwent 647 implant procedures. After matching the two treatment groups by BMI, 94 patients in each treatment group yielding a total of 605 implant procedures were selected for analysis. The two groups were comparable in terms of patient and disease variables. Post-operative wound infection was similar in Group A (n = 11, 12%) compared with Group B (n = 9, 10%; p = 0.8). Univariate analysis revealed only pre-operative radiotherapy to be associated with the development of infection (0.004). Controlling for the effect of radiotherapy, multivariate analysis demonstrated that there was no statistically significant difference between the two methods for infection prevention. Our findings suggest that a single pre-operative dose of intravenous antibiotics is equally as effective as continued antibiotic prophylaxis in preventing immediate infection in patients undergoing implant-based breast reconstructions. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Transfer function modeling of parallel connected two three-phase induction motor implementation using LabView platform

    DEFF Research Database (Denmark)

    Gunabalan, R.; Sanjeevikumar, P.; Blaabjerg, Frede

    2015-01-01

    This paper presents the transfer function modeling and stability analysis of two induction motors of same ratings and parameters connected in parallel. The induction motors are controlled by a single inverter and the entire drive system is modeled using transfer function in LabView. Further...

  11. Fosfomycin in a single dose versus a 7-day course of amoxicillin-clavulanate for the treatment of asymptomatic bacteriuria during pregnancy.

    Science.gov (United States)

    Estebanez, A; Pascual, R; Gil, V; Ortiz, F; Santibáñez, M; Pérez Barba, C

    2009-12-01

    The purpose of this paper was to compare the efficacy of a single dose of 3 g of fosfomycin to that of a 7-day regimen of amoxicillin-clavulanate in the treatment of asymptomatic bacteriuria during pregnancy. A randomised, prospective, interventional, analytical, longitudinal study was undertaken, in which the efficacy of two antibiotic regimens (one short and the other long) in the treatment of pregnant women with asymptomatic bacteriuria is compared. One hundred and nine patients were randomly assigned to two groups: 56 were treated with amoxicillin-clavulanate and 53 with fosfomycin. The two groups were similar in terms of co-morbidity, treatments received during pregnancy, obstetric, gynaecological and surgical history and laboratory data. The efficacy of the two regimens was similar and the eradication rate was over 80% in both groups (P = 0.720) (relative risk [RR] 1.195, 95% confidence interval [CI]: 0.451-3.165). The number of reinfections was greater in the amoxicillin-clavulanate group (P = 0.045). The secondary effects were lower in the fosfomycin group (P = 0.008). There were no significant differences in the number of persistences (P = 0.39), development of symptomatic urinary infections (P = 0.319) or recurrences (P = 0.96). Treatment with a single dose of fosfomycin is as effective as the standard course of treatment with amoxicillin-clavulanate and may be preferable due to its simpler administration and the smaller number of reinfections.

  12. Parallel Factor-Based Model for Two-Dimensional Direction Estimation

    Directory of Open Access Journals (Sweden)

    Nizar Tayem

    2017-01-01

    Full Text Available Two-dimensional (2D Direction-of-Arrivals (DOA estimation for elevation and azimuth angles assuming noncoherent, mixture of coherent and noncoherent, and coherent sources using extended three parallel uniform linear arrays (ULAs is proposed. Most of the existing schemes have drawbacks in estimating 2D DOA for multiple narrowband incident sources as follows: use of large number of snapshots, estimation failure problem for elevation and azimuth angles in the range of typical mobile communication, and estimation of coherent sources. Moreover, the DOA estimation for multiple sources requires complex pair-matching methods. The algorithm proposed in this paper is based on first-order data matrix to overcome these problems. The main contributions of the proposed method are as follows: (1 it avoids estimation failure problem using a new antenna configuration and estimates elevation and azimuth angles for coherent sources; (2 it reduces the estimation complexity by constructing Toeplitz data matrices, which are based on a single or few snapshots; (3 it derives parallel factor (PARAFAC model to avoid pair-matching problems between multiple sources. Simulation results demonstrate the effectiveness of the proposed algorithm.

  13. Fixed-dose combinations of drugs versus single-drug formulations for treating pulmonary tuberculosis

    Science.gov (United States)

    Gallardo, Carmen R; Rigau Comas, David; Valderrama Rodríguez, Angélica; Roqué i Figuls, Marta; Parker, Lucy Anne; Caylà, Joan; Bonfill Cosp, Xavier

    2016-01-01

    Background People who are newly diagnosed with pulmonary tuberculosis (TB) typically receive a standard first-line treatment regimen that consists of two months of isoniazid, rifampicin, pyrazinamide, and ethambutol followed by four months of isoniazid and rifampicin. Fixed-dose combinations (FDCs) of these drugs are widely recommended. Objectives To compare the efficacy, safety, and acceptability of anti-tuberculosis regimens given as fixed-dose combinations compared to single-drug formulations for treating people with newly diagnosed pulmonary tuberculosis. Search methods We searched the Cochrane Infectious Disease Group Specialized Register; the Cochrane Central Register of Controlled Trials (CENTRAL, published in the Cochrane Library, Issue 11 2015); MEDLINE (1966 to 20 November 2015); EMBASE (1980 to 20 November 2015); LILACS (1982 to 20 November 2015); the metaRegister of Controlled Trials; and the World Health Organization International Clinical Trials Registry Platform (WHO ICTRP), without language restrictions, up to 20 November 2015. Selection criteria Randomized controlled trials that compared the use of FDCs with single-drug formulations in adults (aged 15 years or more) newly diagnosed with pulmonary TB. Data collection and analysis Two review authors independently assessed studies for inclusion, and assessed the risk of bias and extracted data from the included trials. We used risk ratios (RRs) for dichotomous data and mean differences (MDs) for continuous data with 95% confidence intervals (CIs). We attempted to assess the effect of treatment for time-to-event measures with hazard ratios and their 95% CIs. We used the Cochrane 'Risk of bias' assessment tool to determine the risk of bias in included trials. We used the fixed-effect model when there was little heterogeneity and the random-effects model with moderate heterogeneity. We used an I² statistic value of 75% or greater to denote significant heterogeneity, in which case we did not perform a

  14. Establishment of computed tomography reference dose levels in Onassis Cardiac Surgery Center

    International Nuclear Information System (INIS)

    Tsapaki, V.; Kyrozi, E.; Syrigou, T.; Mastorakou, I.; Kottou, S.

    2001-01-01

    The purpose of the study was to apply European Commission (EC) Reference Dose Levels (RDL) in Computed Tomography (CT) examinations at Onassis Cardiac Surgery Center (OCSC). These are weighted CT Dose Index (CTDI w ) for a single slice and Dose-Length Product (DLP) for a complete examination. During the period 1998-1999, the total number of CT examinations, every type of CT examination, patient related data and technical parameters of the examinations were recorded. The most frequent examinations were chosen for investigation which were the head, chest, abdomen and pelvis. CTDI measurements were performed and CTDI w and DLP were calculated. Third Quartile values of CTDI w were chosen to be 43mGy for head, 8mGy for chest, and 22mGy for abdomen and pelvis examinations. Third quartile values of DLP were chosen to be 740mGycm for head, 370mGycm for chest, 490mGycm for abdomen and 420mGycm for pelvis examination. Results confirm that OCSC follows successfully the proposed RDL for the head, chest, abdomen and pelvis examinations in terms of radiation dose. (author)

  15. Randomized trial of single dose versus fractionated palliative radiotherapy of bone metastases

    International Nuclear Information System (INIS)

    Nielsen, O.S.; Bentzen, S.M.; Sandberg, E.; Gadeberg, C.C.; Timothy, A.R.

    1998-01-01

    Purpose: Data in the literature suggest that for painful bone metastases a single dose is as effective as fractionated radiotherapy. In the present multicentre prospective trial, the effects of 8 Gy x1 and 5 Gy x4 were compared. Patients and methods: A total of 241 patients were randomized to 8 Gy (122 patients) or 20 Gy (119 patients). The primary tumour was in the breast in 39% of patients, in the prostate in 34% of patients, in the lung in 13% of patients and in other locations in 14% of patients. Outcome measures were pain relief as measured by VAS and in half of the patients also by a five-point categorical pain scale, global quality of life (QoL) and analgesic consumption. Evaluation was performed before and 4, 8, 12 and 20 weeks after treatment. Results: A total of 239 patients were evaluable for response. The two groups did not differ with respect to age, sex, primary tumour, metastasis localization, analgesic consumption (type and dose), performance status, prior systemic treatment, degree of pain and QoL. The treatment was completed as planned in 98% of patients. The degree of pain relief did not differ between the two treatment groups. At 4 weeks the difference in pain relief was 6% (95% CI 7, 20%) and at 8 weeks the difference was 13% (95% CI 3, 28%). Neither was there any significant difference in the duration of pain relief, the number of new painful sites and the need for reirradiation and toxicity was minor. Conclusion: The present randomized study showed that a single fraction of 8 Gy was as effective as 5 Gy x4 in relieving pain from bone metastasis. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  16. The dose dependency of the over-dispersion of quartz OSL single grain dose distributions

    DEFF Research Database (Denmark)

    Thomsen, Kristina Jørkov; Murray, Andrew S.; Jain, Mayank

    2012-01-01

    The use of single grain quartz OSL dating has become widespread over the past decade, particularly with application to samples likely to have been incompletely bleached before burial. By reducing the aliquot size to a single grain the probability of identifying the grain population most likely...... to have been well-bleached at deposition is maximised and thus the accuracy with which the equivalent dose can be determined is – at least in principle – improved. However, analysis of single grain dose distributions requires knowledge of the dispersion of the well-bleached part of the dose distribution....... This can be estimated by measurement of a suitable analogue, e.g. a well-bleached aeolian sample, but this requires such an analogue to be available, and in addition the assumptions that the sample is in fact a) well-bleached, and b) has a similar dose rate heterogeneity to the fossil deposit. Finally...

  17. Perioperative management of patients with antiphospholipid syndrome: a single-center experience.

    Science.gov (United States)

    Atisha-Fregoso, Yemil; Espejo-Poox, Eric; Carrillo-Maravilla, Eduardo; Pulido-Ramírez, Alma Lilia; Lugo Baruqui, Diego; Hernández-Molina, Gabriela; Cabral, Antonio R

    2017-07-01

    The objective was to describe the management and risk factors for complications of antiphospholipid syndrome (APS) patients who underwent a surgical procedure in a single center. We reviewed medical records of all patients with primary or secondary APS who underwent an elective surgery during a 6-year period. Demographical data, management of anticoagulation and complications were recorded. We identified 43 patients, mean age 37.9 ± 8.9 years, who underwent a total of 48 elective surgeries. All patients had history of at least one thrombotic event and were under vitamin K antagonists. Before surgery, all patients received bridging therapy with intravenous infusion of heparin or low molecular weight heparin (LMWH). Among the LMWH group, 36 had a full anticoagulation regimen and nine prophylactic doses. In 62% of the surgeries, we identified an optimal management of periprocedural anticoagulation according to guidelines. Overall six patients had severe bleeding and three thrombotic complications (full anticoagulation regimen n = 2 and prophylactic dose group n = 1). Patients with optimal management of anticoagulation experienced less thrombotic and hemorrhagic complications (7 vs. 33%; OR 0.14, 95% CI 0.02-0.81; p = 0.040) and patients with INR ≤1.5 at surgery had fewer episodes of major bleeding (6 vs. 29%; OR 0.19, 95% CI 0.02-0.98; p = 0.050). All three thrombotic events occurred in patients with INR ≤1.5. Proper management of anticoagulation based on guidelines is associated with less complications in patients with APS. Notwithstanding the proper use of bridging therapy, some patients may develop thrombotic complications.

  18. The effect of dosing regimen on the pharmacokinetics of risedronate

    Science.gov (United States)

    Mitchell, David Y; Heise, Mark A; Pallone, Karen A; Clay, Marian E; Nesbitt, John D; Russell, Darrell A; Melson, Chad W

    1999-01-01

    Aims To examine the effect of timing of a risedronate dose relative to food intake on the rate and extent of risedronate absorption following single-dose, oral administration to healthy male and female volunteers. Methods A single-dose, randomized, parallel study design was conducted with volunteers assigned to four treatment groups (31 or 32 subjects per group, 127 subjects total). Each subject was orally administered 30 mg risedronate. Group 1 was fasted for 10 h prior to and 4 h after dosing (fasted group); Groups 2 and 3 were fasted for 10 h and were dosed 1 and 0.5 h, respectively, before a high-fat breakfast; and Group 4 was dosed 2 h after a standard dinner. Blood and urine samples were collected for 168 h after dosing. Pharmacokinetic parameters were estimated by simultaneous analysis of risedronate serum concentration and urinary excretion rate-time data. Results Extent of risedronate absorption (AUC and Ae) was comparable (P = 0.4) in subjects dosed 2 h after dinner and 0.5 h before breakfast; however, a significantly greater extent of absorption occurred when risedronate was given 1 or 4 h prior to a meal (1.4- to 2.3-fold greater). Administration 0.5, 1, or 4 h prior to a meal resulted in a significantly greater rate of absorption (Cmax 2.8-, 3.5-, and 4.1-fold greater, respectively) when compared with 2 h after dinner. Conclusions The comparable extent of risedronate absorption when administered either 0.5–1 h before breakfast or 2 h after an evening meal support previous clinical studies where risedronate was found to have similar effectiveness using these dosing regimens. This flexibility in the timing of risedronate administration may provide patients an alternative means to achieve the desired efficacy while maintaining their normal daily routine. PMID:10583024

  19. Serum tocopherol levels in very preterm infants after a single dose of vitamin E at birth.

    Science.gov (United States)

    Bell, Edward F; Hansen, Nellie I; Brion, Luc P; Ehrenkranz, Richard A; Kennedy, Kathleen A; Walsh, Michele C; Shankaran, Seetha; Acarregui, Michael J; Johnson, Karen J; Hale, Ellen C; Messina, Lynn A; Crawford, Margaret M; Laptook, Abbot R; Goldberg, Ronald N; Van Meurs, Krisa P; Carlo, Waldemar A; Poindexter, Brenda B; Faix, Roger G; Carlton, David P; Watterberg, Kristi L; Ellsbury, Dan L; Das, Abhik; Higgins, Rosemary D

    2013-12-01

    Our aim was to examine the impact of a single enteral dose of vitamin E on serum tocopherol levels. The study was undertaken to see whether a single dose of vitamin E soon after birth can rapidly increase the low α-tocopherol levels seen in very preterm infants. If so, this intervention could be tested as a means of reducing the risk of intracranial hemorrhage. Ninety-three infants vitamin E or placebo by gastric tube within 4 hours of birth. The vitamin E group received 50 IU/kg of vitamin E as dl-α-tocopheryl acetate (Aquasol E). The placebo group received sterile water. Blood samples were taken for measurement of serum tocopherol levels by high-performance liquid chromatography before dosing and 24 hours and 7 days after dosing. Eighty-eight infants received the study drug and were included in the analyses. The α-tocopherol levels were similar between the groups at baseline but higher in the vitamin E group at 24 hours (median 0.63 mg/dL vs. 0.42 mg/dL, P = .003) and 7 days (2.21 mg/dL vs 1.86 mg/dL, P = .04). There were no differences between groups in γ-tocopherol levels. At 24 hours, 30% of vitamin E infants and 62% of placebo infants had α-tocopherol levels vitamin E raised serum α-tocopherol levels, but to consistently achieve α-tocopherol levels >0.5 mg/dL, a higher dose or several doses of vitamin E may be needed.

  20. Efficacy of low-dose cinacalcet on alternate days for the treatment of secondary hyperparathyroidism in hemodialysis patients: a single-center study

    Directory of Open Access Journals (Sweden)

    Gojaseni P

    2017-02-01

    Full Text Available Pongsathorn Gojaseni, Dolnapa Pattarathitinan, Anutra Chittinandana Division of Nephrology, Department of Medicine, Bhumibol Adulyadej Hospital, Directorate of Medical Services, Royal Thai Air Force, Bangkok, Thailand Introduction: Cinacalcet is effective in reducing serum parathyroid hormone (PTH in patients with secondary hyperparathyroidism (HPT. This study focused on testing whether a prescription of low-dose cinacalcet on alternate days could be an option for treatment of secondary HPT.Materials and methods: A retrospective clinical study was conducted on chronic maintenance hemodialysis patients. Patients with secondary HPT who received cinacalcet at a starting dose of 25 mg on alternate days were reviewed (low-dose group. Patients who were being treated with a standard dose of cinacalcet in the same period of time were selected as the control group. The primary outcome was difference in the percentage of patients achieving >30% reduction of intact parathyroid hormone (iPTH levels at 16 weeks. The changes of serum iPTH and other biochemical data were also tested.Results: A total of 30 patients (16 low doses and 14 controls took part in the study. Baseline iPTH levels in the low-dose and control group were 1,065.9±477.7 and 1,214.1±497.6 pg/mL, respectively (p=0.413. The analysis showed that the percentage of patients who achieved the primary outcome showed little or no difference (33.3% in the low-dose group compared with 38.5% in the control group, p=1.0. Serum iPTH reduction during 16 weeks of study period in the low-dose and control group was 253.5±316.1 and 243.4±561.3 pg/mL, respectively (p=0.957. There was no difference in the adverse events between both groups.Conclusion: Among patients with secondary HPT, initial treatment with cinacalcet 25 mg on alternate days can decrease serum PTH levels. The role of low-dose cinacalcet in secondary HPT should be further determined in large-scale, randomized controlled trials. Keywords

  1. Economic and microbiologic evaluation of single-dose vial extension for hazardous drugs.

    Science.gov (United States)

    Rowe, Erinn C; Savage, Scott W; Rutala, William A; Weber, David J; Gergen-Teague, Maria; Eckel, Stephen F

    2012-07-01

    The update of US Pharmacopeia Chapter in 2008 included guidelines stating that single-dose vials (SDVs) opened and maintained in an International Organization for Standardization Class 5 environment can be used for up to 6 hours after initial puncture. A study was conducted to evaluate the cost of discarding vials after 6 hours and to further test sterility of vials beyond this time point, subsequently defined as the beyond-use date (BUD). Financial determination of SDV waste included 2 months of retrospective review of all doses prescribed. Additionally, actual waste log data were collected. Active and control vials (prepared using sterilized trypticase soy broth) were recovered, instead of discarded, at the defined 6-hour BUD. The institution-specific waste of 19 selected SDV medications discarded at 6 hours was calculated at $766,000 annually, and tracking waste logs for these same medications was recorded at $770,000 annually. Microbiologic testing of vial extension beyond 6 hours showed that 11 (1.86%) of 592 samples had one colony-forming unit on one of two plates. Positive plates were negative at subsequent time points, and all positives were single isolates most likely introduced during the plating process. The cost of discarding vials at 6 hours was significant for hazardous medications in a large academic medical center. On the basis of microbiologic data, vial BUD extension demonstrated a contamination frequency of 1.86%, which likely represented exogenous contamination; vial BUD extension for the tested drugs showed no growth at subsequent time points and could provide an annual cost savings of more than $600,000.

  2. SU-E-T-263: Point Dose Variation Using a Single Ir-192 HDR Brachytherapy Plan for Two Treatments with a Single Tandem-Ovoid Insertion for Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Liang, X; Morrill, S; Hardee, M; Han, E; Penagaricano, J; Zhang, X; Vaneerat, R [University of Arkansas Medical Science, Little Rock, AR (United States)

    2014-06-01

    Purpose: To evaluate the point dose variations between Ir-192 HDR treatments on two consecutive days using a single tandem-ovoid insertion without replanning in cervical cancer patients. Methods: This study includes eleven cervical cancer patients undergoing HDR brachytherapy with a prescribed dose of 28 Gy in 4 fractions. Each patient had two tandemovoid insertions one week apart. Each insertion was treated on consecutive days with rescanning and replanning prior to each treatment. To study the effect of no replanning for day 2 treatments, the day 1 plan dwell position and dwell time with decay were applied to the day 2 CT dataset. The point dose variations on the prescription point H (defined according to American Brachytherapy Society), and normal tissue doses at point B, bladder, rectum and vaginal mucosa (based on ICRU Report 38) were obtained. Results: Without replanning, the mean point H dose variation was 4.6 ± 10.7% on the left; 2.3 ± 2.9% on the right. The mean B point variation was 3.8 ± 4.9% on the left; 3.6 ± 4.7% on the right. The variation in the left vaginal mucosal point was 12.2 ± 10.7%; 9.5 ± 12.5% on the right; the bladder point 5.5 ± 7.4%; and the rectal point 7.9 ± 9.1%. Conclusion: Without replanning, there are variations both in the prescription point and the normal tissue point doses. The latter can vary as much as 10% or more. This is likely due to the steep dose gradient from brachytherapy compounded by shifts in the positions of the applicator in relationship to the patients anatomy. Imaging prior to each treatment and replanning ensure effective and safe brachytherapy are recommended.

  3. Biochemical and immunological responses to low doses of ionizing radiation

    International Nuclear Information System (INIS)

    Shabon, M.H.; Sayed, Z.S.; Mahdy, E.M.; El-Gawish, M.A.; Shosha, W.

    2006-01-01

    Malondialdehyde, lactate dehydrogenase, iron concentration, IL-6 and IL-1b concentration, hemoglobin content, red cells, white cells and platelet counts were determined in seventy-two male albino rats divided into two main groups. The first one was subdivided into 7 subgroups; control and 6 irradiated subgroups with 0.1, 0.2, 0.3, 0.5, 0.7 and 1 Gy single dose of gamma radiation. The other was subdivided into 4 subgroups irradiated with fractionated doses of gamma radiation; three groups were irradiated with 0.3, 0.7 and 1 Gy (0.1 Gy/day) and the last subgroup with 1 Gy (0.2 Gy/day). All animals were sacrificed after three days of the last irradiation dose. The results revealed that all biochemical parameters were increased in rats exposed to fractionated doses more than the single doses. Hematological parameters were decreased in rats exposed to single doses more than the fractionated ones. In conclusion, the data of this study highlights the stimulatory effect of low ionizing radiation doses (= 1 Gy), whether single or fractionated, on some biochemical and immunological parameters

  4. Low dose radiation enhance the anti-tumor effect of high dose radiation on human glioma cell U251

    International Nuclear Information System (INIS)

    Wang Chang; Wang Guanjun; Tan Yehui; Jiang Hongyu; Li Wei

    2008-01-01

    Objective: To detect the effect on the growth of human glioma cell U251 induced by low dose irradiation and low dose irradiation combined with large dose irradiation. Methods: Human glioma cell line U251 and nude mice carried with human glioma were used. The tumor cells and the mice were treated with low dose, high dose, and low dose combined high dose radiation. Cells growth curve, MTT and flow cytometry were used to detect the proliferation, cell cycle and apoptosis of the cells; and the tumor inhibition rate was used to assess the growth of tumor in vivo. Results: After low dose irradiation, there was no difference between experimental group and control group in cell count, MTT and flow cytometry. Single high dose group and low dose combined high dose group both show significantly the suppressing effect on tumor cells, the apoptosis increased and there was cell cycle blocked in G 2 period, but there was no difference between two groups. In vivo apparent anti-tumor effect in high dose radiation group and the combining group was observed, and that was more significant in the combining group; the prior low dose radiation alleviated the injury of hematological system. There was no difference between single low dose radiation group and control. Conclusions: There is no significant effect on human glioma cell induced by low dose radiation, and low dose radiation could not induce adaptive response. But in vivo experience, low dose radiation could enhance the anti-tumor effect of high dose radiation and alleviated the injury of hematological system. (authors)

  5. Prospective randomized comparison of rotational angiography with three-dimensional reconstruction and computed tomography merged with electro-anatomical mapping: a two center atrial fibrillation ablation study.

    Science.gov (United States)

    Anand, Rishi; Gorev, Maxim V; Poghosyan, Hermine; Pothier, Lindsay; Matkins, John; Kotler, Gregory; Moroz, Sarah; Armstrong, James; Nemtsov, Sergei V; Orlov, Michael V

    2016-08-01

    To compare the efficacy and accuracy of rotational angiography with three-dimensional reconstruction (3DATG) image merged with electro-anatomical mapping (EAM) vs. CT-EAM. A prospective, randomized, parallel, two-center study conducted in 36 patients (25 men, age 65 ± 10 years) undergoing AF ablation (33 % paroxysmal, 67 % persistent) guided by 3DATG (group 1) vs. CT (group 2) image fusion with EAM. 3DATG was performed on the Philips Allura Xper FD 10 system. Procedural characteristics including time, radiation exposure, outcome, and navigation accuracy were compared between two groups. There was no significant difference between the groups in total procedure duration or time spent for various procedural steps. Minor differences in procedural characteristics were present between two centers. Segmentation and fusion time for 3DATG or CT-EAM was short and similar between both centers. Accuracy of navigation guided by either method was high and did not depend on left atrial size. Maintenance of sinus rhythm between the two groups was no different up to 24 months of follow-up. This study did not find superiority of 3DATG-EAM image merge to guide AF ablation when compared to CT-EAM fusion. Both merging techniques result in similar navigation accuracy.

  6. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Healy, W.L.; Lo, T.C.; Covall, D.J.; Pfeifer, B.A.; Wasilewski, S.A.

    1990-01-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700 centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy

  7. Experimental studies in a single-phase parallel channel natural circulation system. Preliminary results

    International Nuclear Information System (INIS)

    Bodkha, Kapil; Pilkhwal, D.S.; Jana, S.S.; Vijayan, P.K.

    2016-01-01

    Natural circulation systems find extensive applications in industrial engineering systems. One of the applications is in nuclear reactor where the decay heat is removed by natural circulation of the fluid under off-normal conditions. The upcoming reactor designs make use of natural circulation in order to remove the heat from core under normal operating conditions also. These reactors employ multiple vertical fuel channels with provision of on-power refueling/defueling. Natural circulation systems are relatively simple, safe and reliable when compared to forced circulation systems. However, natural circulation systems are prone to encounter flow instabilities which are highly undesirable for various reasons. Presence of parallel channels under natural circulation makes the system more complicated. To examine the behavior of parallel channel system, studies were carried out for single-phase natural circulation flow in a multiple vertical channel system. The objective of the present work is to study the flow behavior of the parallel heated channel system under natural circulation for different operating conditions. Steady state and transient studies have been carried out in a parallel channel natural circulation system with three heated channels. The paper brings out the details of the system considered, different cases analyzed and preliminary results of studies carried out on a single-phase parallel channel system.

  8. Massively parallel read mapping on GPUs with the q-group index and PEANUT

    NARCIS (Netherlands)

    J. Köster (Johannes); S. Rahmann (Sven)

    2014-01-01

    textabstractWe present the q-group index, a novel data structure for read mapping tailored towards graphics processing units (GPUs) with a small memory footprint and efficient parallel algorithms for querying and building. On top of the q-group index we introduce PEANUT, a highly parallel GPU-based

  9. Helical Tomotherapy Versus Single-Arc Intensity-Modulated Arc Therapy: A Collaborative Dosimetric Comparison Between Two Institutions

    International Nuclear Information System (INIS)

    Rong Yi; Tang, Grace; Welsh, James S.; Mohiuddin, Majid M.; Paliwal, Bhudatt; Yu, Cedric X.

    2011-01-01

    Purpose: Both helical tomotherapy (HT) and single-arc intensity-modulated arc therapy (IMAT) deliver radiation using rotational beams with multileaf collimators. We report a dual-institution study comparing dosimetric aspects of these two modalities. Methods and Materials: Eight patients each were selected from the University of Maryland (UMM) and the University of Wisconsin Cancer Center Riverview (UWR), for a total of 16 cases. Four cancer sites including brain, head and neck (HN), lung, and prostate were selected. Single-arc IMAT plans were generated at UMM using Varian RapidArc (RA), and HT plans were generated at UWR using Hi-Art II TomoTherapy. All 16 cases were planned based on the identical anatomic contours, prescriptions, and planning objectives. All plans were swapped for analysis at the same time after final approval. Dose indices for targets and critical organs were compared based on dose-volume histograms, the beam-on time, monitor units, and estimated leakage dose. After the disclosure of comparison results, replanning was done for both techniques to minimize diversity in optimization focus from different operators. Results: For the 16 cases compared, the average beam-on time was 1.4 minutes for RA and 4.8 minutes for HT plans. HT provided better target dose homogeneity (7.6% for RA and 4.2% for HT) with a lower maximum dose (110% for RA and 105% for HT). Dose conformation numbers were comparable, with RA being superior to HT (0.67 vs. 0.60). The doses to normal tissues using these two techniques were comparable, with HT showing lower doses for more critical structures. After planning comparison results were exchanged, both techniques demonstrated improvements in dose distributions or treatment delivery times. Conclusions: Both techniques created highly conformal plans that met or exceeded the planning goals. The delivery time and total monitor units were lower in RA than in HT plans, whereas HT provided higher target dose uniformity.

  10. The effect of inhaled budesonide on symptoms, lung function, and cold air and methacholine responsiveness in 2- to 5-year-old asthmatic children

    DEFF Research Database (Denmark)

    Nielsen, K G; Bisgaard, H

    2000-01-01

    ) with moderately severe asthma in a single-center, randomized, double-blind, parallel-group, placebo-controlled study involving 8 wk of treatment. Budesonide (BUD) 400 microgram twice daily was administered via a pressurized metered-dose inhaler and metal spacer device. Symptom scores (SSc) and use of short...

  11. Study of single dose toxic test of Sweet Bee Venom in Beagle Dogs

    Directory of Open Access Journals (Sweden)

    Hye-Chul, Yoon

    2010-12-01

    Full Text Available Objectives : This study was performed to analyse single dose toxicity of Sweet Bee Venom(Sweet BV extracted from the bee venom in Beagle dogs. Methods : All experiments were conducted under the regulations of Good Laboratory Practice (GLP at Biotoxtech Company, a non-clinical study authorized institution. Male and female Beagle dogs of 5-6 months old were chosen for the pilot study of single dose toxicity of Sweet BV which was administered at the level of 9.0 ㎎/㎏ body weight which is 1300 times higher than the clinical application dosage as the high dosage, followed by 3.0 and 1.0 ㎎/㎏ as midium and low dosage, respectively. Equal amount of excipient(normal saline to the Sweet BV experiment groups was administered as the control group. Results : 1. No mortality was witnessed in all of the experiment groups. 2. Hyperemia and movement disorder were observed around the area of administration in all the experiment groups, and higher occurrence in the higher dosage treatment. 3. For weight measurement, Neither male nor female groups showed significant changes. 4. To verify abnormalities of organs and tissues, thigh muscle which treated with Sweet BV, brain, liver, lung, kidney, and spinal cords were removed and histologocal observation using H-E staining was conducted. In the histologocal observation of thigh muscle, cell infiltration, inflammation, degeneration, necrosis of muscle fiber, and fibrosis were found in both thigh tissue. And the changes depend on the dose of Sweet BV. But the other organs did not showed in any abnormality. 5. The maximum dose of Sweet BV in Beagle dogs were over 9 ㎎/㎏ in this study. Conclusions : The above findings of this study suggest that Sweet BV is a relatively safe treatment medium. Further studies on the toxicity of Sweet BV should be conducted to yield more concrete evidences.

  12. Efficacy of a Radiation Absorbing Shield in Reducing Dose to the Interventionalist During Peripheral Endovascular Procedures: A Single Centre Pilot Study

    International Nuclear Information System (INIS)

    Power, S.; Mirza, M.; Thakorlal, A.; Ganai, B.; Gavagan, L. D.; Given, M. F.; Lee, M. J.

    2015-01-01

    PurposeThis prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures.Materials and MethodsA commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated.ResultsTLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142).ConclusionInitial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator’s body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study

  13. Efficacy of a Radiation Absorbing Shield in Reducing Dose to the Interventionalist During Peripheral Endovascular Procedures: A Single Centre Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Power, S.; Mirza, M.; Thakorlal, A.; Ganai, B.; Gavagan, L. D.; Given, M. F.; Lee, M. J., E-mail: mlee@rcsi.ie [Beaumont Hospital, Imaging and Interventional Radiology Department (Ireland)

    2015-06-15

    PurposeThis prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures.Materials and MethodsA commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated.ResultsTLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142).ConclusionInitial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator’s body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.

  14. Building a parallel file system simulator

    International Nuclear Information System (INIS)

    Molina-Estolano, E; Maltzahn, C; Brandt, S A; Bent, J

    2009-01-01

    Parallel file systems are gaining in popularity in high-end computing centers as well as commercial data centers. High-end computing systems are expected to scale exponentially and to pose new challenges to their storage scalability in terms of cost and power. To address these challenges scientists and file system designers will need a thorough understanding of the design space of parallel file systems. Yet there exist few systematic studies of parallel file system behavior at petabyte- and exabyte scale. An important reason is the significant cost of getting access to large-scale hardware to test parallel file systems. To contribute to this understanding we are building a parallel file system simulator that can simulate parallel file systems at very large scale. Our goal is to simulate petabyte-scale parallel file systems on a small cluster or even a single machine in reasonable time and fidelity. With this simulator, file system experts will be able to tune existing file systems for specific workloads, scientists and file system deployment engineers will be able to better communicate workload requirements, file system designers and researchers will be able to try out design alternatives and innovations at scale, and instructors will be able to study very large-scale parallel file system behavior in the class room. In this paper we describe our approach and provide preliminary results that are encouraging both in terms of fidelity and simulation scalability.

  15. Final Report: Center for Programming Models for Scalable Parallel Computing

    Energy Technology Data Exchange (ETDEWEB)

    Mellor-Crummey, John [William Marsh Rice University

    2011-09-13

    As part of the Center for Programming Models for Scalable Parallel Computing, Rice University collaborated with project partners in the design, development and deployment of language, compiler, and runtime support for parallel programming models to support application development for the “leadership-class” computer systems at DOE national laboratories. Work over the course of this project has focused on the design, implementation, and evaluation of a second-generation version of Coarray Fortran. Research and development efforts of the project have focused on the CAF 2.0 language, compiler, runtime system, and supporting infrastructure. This has involved working with the teams that provide infrastructure for CAF that we rely on, implementing new language and runtime features, producing an open source compiler that enabled us to evaluate our ideas, and evaluating our design and implementation through the use of benchmarks. The report details the research, development, findings, and conclusions from this work.

  16. Estimation of individual doses from external exposures and dose-group classification of cohort members in high background radiation area in Yangjiang, China

    International Nuclear Information System (INIS)

    Yuan Yongling; Shen Hong; Sun Quanfu; Wei Luxin

    1999-01-01

    Objective: In order to estimate annual effective doses from external exposures in the high background radiation area (HBRA) and in the control area (CA) , the authors measured absorbed dose rates in air from terrestrial gamma radiation with different dosimeters. A dose group classification was an important step for analyzing the dose effects relationship among the cohort members in the investigated areas. The authors used the hamlet specific average annual effective doses of all the 526 hamlets in the investigated areas. A classification of four dose groups was made for the cohort members (high, moderate, low and control) . Methods: For the purpose of studying the dose effect relationships among the cohort members in HBRA and CA, it would be ideal that each subject has his own record of individual accumulated doses received before the evaluation. However, rt is difficult to realize it in practice (each of 106517 persons should wear TLD for a long time) . Thus the authors planned two sets of measurements. Firstly, to measure the environmental dose rates (outdoor, indoor, over the bed) in every hamlet of the investigated area (526 hamlets) , considering the occupancy factors for males and females of different age groups to convert to the annual effective dose from the data of dose rates. Secondly, to measure the individual cumulative dose with TLD for part of the subjects in the investigated areas. Results: Based on the two sets of measurements, the estimates of average annual effective doses in HBRA were 211.86 and 206.75 x 10 -5 Sv/a, respectively, 68.60 and 67.11 x 10 -5 Sv/a, respectively(gamma radiation only) . The intercomparison between these two sets of measurement showed that they were in good correlation. Thus the authors are able to yield the equations of linear regression: Y = 0.9937 + 6.0444, r = 0.9949. Conclusions: The authors took the value obtained from direct measurement as 'standard' , and 15 % for uncertainty of measurement. Since the estimates of

  17. Optical determination and magnetic manipulation of a single nitrogen-vacancy color center in diamond nanocrystal

    International Nuclear Information System (INIS)

    Diep Lai, Ngoc; Zheng, Dingwei; Treussart, François; Roch, Jean-François

    2010-01-01

    The controlled and coherent manipulation of individual quantum systems is fundamental for the development of quantum information processing. The nitrogen-vacancy (NV) color center in diamond is a promising system since its photoluminescence is perfectly stable at room temperature and its electron spin can be optically read out at the individual level. We review here the experiments currently realized in our laboratory concerning the use of a single NV color center as the single photon source and the coherent magnetic manipulation of the electron spin associated with a single NV color center. Furthermore, we demonstrate a nanoscopy experiment based on the saturation absorption effect, which allows to optically pin-point a single NV color center at sub-λ resolution. This offers the possibility to independently address two or multiple magnetically coupled single NV color centers, which is a necessary step towards the realization of a diamond-based quantum computer

  18. Multi-group dynamic quantum secret sharing with single photons

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hongwei [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Ma, Haiqiang, E-mail: hqma@bupt.edu.cn [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Wei, Kejin [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Yang, Xiuqing [School of Science, Beijing Jiaotong University, Beijing 100044 (China); Qu, Wenxiu; Dou, Tianqi; Chen, Yitian; Li, Ruixue; Zhu, Wu [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China)

    2016-07-15

    In this letter, we propose a novel scheme for the realization of single-photon dynamic quantum secret sharing between a boss and three dynamic agent groups. In our system, the boss can not only choose one of these three groups to share the secret with, but also can share two sets of independent keys with two groups without redistribution. Furthermore, the security of communication is enhanced by using a control mode. Compared with previous schemes, our scheme is more flexible and will contribute to a practical application. - Highlights: • A multi-group dynamic quantum secret sharing with single photons scheme is proposed. • Any one of the groups can be chosen to share secret through controlling the polarization of photons. • Two sets of keys can be shared simultaneously without redistribution.

  19. single dose pharmacokinetics of mefloquine in healthy nigerian

    African Journals Online (AJOL)

    BSN

    Mefloquine 500mg single dose was administered and blood samples were collected ... particle size ODS Hypersil (HETP, Macclesfield, UK) at a pressure of 55 Mpa .... dose to area under the plasma drug concentration - time curve, assuming ...

  20. Numeric algorithms for parallel processors computer architectures with applications to the few-groups neutron diffusion equations

    International Nuclear Information System (INIS)

    Zee, S.K.

    1987-01-01

    A numeric algorithm and an associated computer code were developed for the rapid solution of the finite-difference method representation of the few-group neutron-diffusion equations on parallel computers. Applications of the numeric algorithm on both SIMD (vector pipeline) and MIMD/SIMD (multi-CUP/vector pipeline) architectures were explored. The algorithm was successfully implemented in the two-group, 3-D neutron diffusion computer code named DIFPAR3D (DIFfusion PARallel 3-Dimension). Numerical-solution techniques used in the code include the Chebyshev polynomial acceleration technique in conjunction with the power method of outer iteration. For inner iterations, a parallel form of red-black (cyclic) line SOR with automated determination of group dependent relaxation factors and iteration numbers required to achieve specified inner iteration error tolerance is incorporated. The code employs a macroscopic depletion model with trace capability for selected fission products' transients and critical boron. In addition to this, moderator and fuel temperature feedback models are also incorporated into the DIFPAR3D code, for realistic simulation of power reactor cores. The physics models used were proven acceptable in separate benchmarking studies

  1. Ionizing acceleration of color center transformation in the low radiation dose range

    International Nuclear Information System (INIS)

    Mamontov, A.P.; Starodubtsev, V.A.; Chernov, I.P.

    1985-01-01

    The purpose of the study is investigation of annealing and colour centers transformation of known nature in lithium fluoride crystals at the γ-irradiation low doses. The controlled colour centers have been introduced by LiF monocrystal samples irradiation by protons with 6 MeV energy. The γ-radiation dose rate constitutes 25 Grxssup(-1). The variation of absorption spectra caused by proton and γ-irradiation in initial crystals and in the sample being twice exposed has been studied. It is shown that for LiF monocrystals in the γ-radiation low dose range (below 5 kGr) anomalous dependences of concentration of F-aggregate colour centers on the irradiation dose are observed. High efficiency in defects transformation can be caused by the chain of self-sustaining reactions. The observed N-type dependences caused defects decay and competition of the processes of capture of anionic vacancies by F- and F-aggregate centers

  2. Parallel and serial grouping of image elements in visual perception

    NARCIS (Netherlands)

    Houtkamp, R.; Roelfsema, P.R.

    2010-01-01

    The visual system groups image elements that belong to an object and segregates them from other objects and the background. Important cues for this grouping process are the Gestalt criteria, and most theories propose that these are applied in parallel across the visual scene. Here, we find that

  3. Two-state ion heating at quasi-parallel shocks

    International Nuclear Information System (INIS)

    Thomsen, M.F.; Gosling, J.T.; Bame, S.J.; Onsager, T.G.; Russell, C.T.

    1990-01-01

    In a previous study of ion heating at quasi-parallel shocks, the authors showed a case in which the ion distributions downstream from the shock alternated between a cooler, denser, core/shoulder type and a hotter, less dense, more Maxwellian type. In this paper they further document the alternating occurrence of two different ion states downstream from several quasi-parallel shocks. Three separate lines of evidence are presented to show that the two states are not related in an evolutionary sense, but rather both are produced alternately at the shock: (1) the asymptotic downstream plasma parameters (density, ion temperature, and flow speed) are intermediate between those characterizing the two different states closer to the shock, suggesting that the asymptotic state is produced by a mixing of the two initial states; (2) examples of apparently interpenetrating (i.e., mixing) distributions can be found during transitions from one state to the other; and (3) examples of both types of distributions can be found at actual crossings of the shock ramp. The alternation between the two different types of ion distribution provides direct observational support for the idea that the dissipative dynamics of at least some quasi-parallel shocks is non-stationary and cyclic in nature, as demonstrated by recent numerical simulations. Typical cycle times between intervals of similar ion heating states are ∼2 upstream ion gyroperiods. Both the simulations and the in situ observations indicate that a process of coherent ion reflection is commonly an important part of the dissipation at quasi-parallel shocks

  4. Results of Hematopoietic Stem Cell Transplantation After Treatment With Different High-Dose Total-Body Irradiation Regimens in Five Dutch Centers

    International Nuclear Information System (INIS)

    Loes van Kempen-Harteveld, M.; Brand, Ronald; Kal, Henk B.; Verdonck, Leo F.; Hofman, Pieter; Schattenberg, Anton V.; Maazen, Richard W. van der; Cornelissen, Jan J.; Eijkenboom, Wil M.H.; Lelie, Johannes P. van der; Oldenburger, Foppe; Barge, Renee M.; Biezen, Anja van; Vossen, Jaak M.J.J.; Noordijk, Evert M.; Struikmans, Henk

    2008-01-01

    Purpose: To evaluate results of high-dose total-body irradiation (TBI) regimens for hematopoietic stem cell transplantation. Methods and Materials: A total of 1,032 patients underwent TBI in one or two fractions before autologous or allogeneic hematologic stem cell transplantation for acute leukemia and non-Hodgkin's lymphoma. The TBI regimens were normalized by using the biological effective dose (BED) concept. The BED values were divided into three dose groups. Study end points were relapse incidence (RI), non-relapse mortality (NRM), relapse-free survival (RFS), and overall survival (OS). Multivariate analysis was performed, stratified by disease. Results: In the highest TBI dose group, RI was significantly lower and NRM was higher vs. the lower dose groups. However, a significant influence on RFS and OS was not found. Relapses in the eye region were found only after shielding to very low doses. Age was of significant influence on OS, RFS, and NRM in favor of younger patients. The NRM of patients older than 40 years significantly increased, and OS decreased. There was no influence of age on RI. Men had better OS and RFS and lower NRM. Type of transplantation significantly influenced RI and NRM for patients with acute leukemia and non-Hodgkin's lymphoma. There was no influence on RFS and OS. Conclusions: Both RI and NRM were significantly influenced by the size of the BED of single-dose or two-fraction TBI regimens; OS and RFS were not. Age was of highly significant influence on NRM, but there was no influence of age on RI. Hyperfractionated TBI with a high BED might be useful, assuming NRM can be reduced

  5. Bioequivalence of isoniazid in a two drug fixed dose combination and in a single drug dosage form.

    Science.gov (United States)

    Agrawal, S; Kaul, C L; Panchagnula, R

    2001-08-01

    To increase the patient compliance and reduce the risk of drug resistant strains, WHO and IUATLD recommend the use of Fixed Dose Combination (FDC) tablets as a routine therapeutic regimen in Directly Observed Treatment Shortcourse (DOTS). But the main issue in the use of FDC is the quality of the formulation. At present WHO and IUATLD suggest the bioequivalence assessment of only rifampicin from FDC compared to separate formulations. For the therapeutic effectiveness all the components of the FDCs should be bioavailable at tissue site. Also, the primary and acquired resistance rate of isoniazid is much higher compared to other anti-tubercular drugs. Hence, a comparative bioavailability study of isoniazid from a two drugs FDC compared to a separate formulation was carried out on a group of 12 healthy volunteers. When evaluated by normal or log transformed confidence interval, Two Way ANOVA and Hauschke analysis, the bioequivalence limits for AUC0-8 and AUC0-24 were within 0.8-1.25. For Cmax and Tmax, these limits were within 0.7-1.43. Hence, isoniazid from a FDC formulation was found to be bioequivalent to a separate formulation at same dose levels.

  6. The Comparison of Two Types of Treatment (High Dose and Low Dose IVIG in Children with GBS in Mofid Hospital

    Directory of Open Access Journals (Sweden)

    Parvaneh Karim-Zadeh

    2003-12-01

    Full Text Available Objective: Acute inflammatory demyelinating peripheral neuropathy (Guillain-Barre-Syndrome is by far the most common cause of immune–mediated peripheral nerve disease in children and with the near disappearance of poliomyelitis, is responsible for the great majority of cases of acute flaccid paralysis. Several controlled studies have done with corticosteroids, plasma pheresis and IVIG in pediatric patients. IVIG treatment can be done in two types of treatment: 1- High dose that means 1gr/kg/day for 2 days. 2- Low dose that means 400mg/kg/day for 5 days. Several studies in other countries have shown faster rate of recovery in patients who received total dose of IVIG in 2 days as opposed to 5 days. Materials & Methods: Because we have not any study about this two types of treatment in IRAN we decided to comparison this two types of IVIG treatment. So the patients that referred to Mofid children hospital for weakness and we diagnosed GBS (with history, physical examination, laboratories and EMG-NCV are divided in two groups: 1- High dose IVIG treatment (experimental group. 2- Low dose IVIG treatment (control group Then the results evaluated. Results: Our findings included that in high dose IVIG therapy we have faster rate of recovery and the Hospital stay is shorter than low dose IVIG-therapy. Also in this type of treatment “because the patients cure faster” , so complications are decreased in them. In the group of high dose IVIG therapy, lower and upper extremities weakness decreased in time. Conclusion: We did not receive any relationship between side effects of drugs and the type of treatment. The relationship between high dose IVIG therapy and drug side effects was not significant.

  7. Parallel computation for distributed parameter system-from vector processors to Adena computer

    Energy Technology Data Exchange (ETDEWEB)

    Nogi, T

    1983-04-01

    Research on advanced parallel hardware and software architectures for very high-speed computation deserves and needs more support and attention to fulfil its promise. Novel architectures for parallel processing are being made ready. Architectures for parallel processing can be roughly divided into two groups. One is a vector processor in which a single central processing unit involves multiple vector-arithmetic registers. The other is a processor array in which slave processors are connected to a host processor to perform parallel computation. In this review, the concept and data structure of the Adena (alternating-direction edition nexus array) architecture, which is conformable to distributed-parameter simulation algorithms, are described. 5 references.

  8. An exploratory, randomized, parallel-group, open-label, relative bioavailability study with an additional two-period crossover food-effect study exploring the pharmacokinetics of two novel formulations of pexmetinib (ARRY-614

    Directory of Open Access Journals (Sweden)

    Wollenberg LA

    2015-09-01

    Full Text Available Lance A Wollenberg,1 Donald T Corson,2,3 Courtney A Nugent,1 Farran L Peterson,1 Ann M Ptaszynski,1 Alisha Arrigo,2,3 Coralee G Mannila,2,3 Kevin S Litwiler,1 Stacie J Bell1,4 1Array BioPharma, Boulder, 2Array BioPharma, Longmont, CO, 3Avista Pharma Solutions, Longmont, CO, 4Mallinckrodt Pharmaceuticals, Ellicott City, MD, USA Background: Pexmetinib (ARRY-614 is a dual inhibitor of p38 mitogen-activated protein kinase and Tie2 signaling pathways implicated in the pathogenesis of myelodysplastic syndromes. Previous clinical experience in a Phase I dose-escalation study of myelodysplastic syndrome patients using pexmetinib administered as neat powder-in-capsule (PIC exhibited high variability in pharmacokinetics and excessive pill burden, prompting an effort to improve the formulation of pexmetinib. Methods: A relative bioavailability assessment encompassed three parallel treatment cohorts of unique subjects comparing the two new formulations (12 subjects per cohort, a liquid oral suspension (LOS and liquid-filled capsule (LFC and the current clinical PIC formulation (six subjects in a fasted state. The food-effect assessment was conducted as a crossover of the LOS and LFC formulations administered under fed and fasted conditions. Subjects were divided into two groups of equal size to evaluate potential period effects on the food-effect assessment. Results: The geometric mean values of the total plasma exposures based upon area-under-the-curve to the last quantifiable sample (AUClast of pexmetinib were approximately four- and twofold higher after administration of the LFC and LOS formulations, respectively, than after the PIC formulation, when the formulations were administered in the fasted state. When the LFC formulation was administered in the fed state, pexmetinib AUClast decreased by <5% compared with the fasted state. After administration of the LOS formulation in the fed state, pexmetinib AUClast was 34% greater than observed in the fasted

  9. High performance computing of density matrix renormalization group method for 2-dimensional model. Parallelization strategy toward peta computing

    International Nuclear Information System (INIS)

    Yamada, Susumu; Igarashi, Ryo; Machida, Masahiko; Imamura, Toshiyuki; Okumura, Masahiko; Onishi, Hiroaki

    2010-01-01

    We parallelize the density matrix renormalization group (DMRG) method, which is a ground-state solver for one-dimensional quantum lattice systems. The parallelization allows us to extend the applicable range of the DMRG to n-leg ladders i.e., quasi two-dimension cases. Such an extension is regarded to bring about several breakthroughs in e.g., quantum-physics, chemistry, and nano-engineering. However, the straightforward parallelization requires all-to-all communications between all processes which are unsuitable for multi-core systems, which is a mainstream of current parallel computers. Therefore, we optimize the all-to-all communications by the following two steps. The first one is the elimination of the communications between all processes by only rearranging data distribution with the communication data amount kept. The second one is the avoidance of the communication conflict by rescheduling the calculation and the communication. We evaluate the performance of the DMRG method on multi-core supercomputers and confirm that our two-steps tuning is quite effective. (author)

  10. A prospective, parallel group, open-labeled, comparative, multi-centric, active controlled study to evaluate the safety, tolerability and benefits of fixed dose combination of acarbose and metformin versus metformin alone in type 2 diabetes.

    Science.gov (United States)

    Jayaram, S; Hariharan, R S; Madhavan, R; Periyandavar, I; Samra, S S

    2010-11-01

    The present study was a prospective, parallel group, open-labeled, comparative, multicentric, active controlled study to evaluate the safety, tolerability and benefits of fixed dose combination of acarbose and metformin versus metformin alone in type 2 diabetic patients. A total of 229 patients with type 2 diabetes were enrolled at 5 medical centers across India. They received either acarbose (50 mg) + metformin (500 mg) bid/tid (n=115) or metformin monotherapy (500 mg) bid/ tid (n=114) for 12 weeks. Primary objective was to evaluate safety and tolerability based on the adverse events reported. Secondary objective was efficacy assessment based on changes in fasting, post prandial blood glucose and HbA1c values. In the acarbose + metformin group 10 patients reported 14 adverse events while in metformin group 9 patients reported 10 adverse events. No patient reported any serious adverse event or was withdraw from study because of adverse events. In the acarbose plus metformin group fasting blood glucose (FBG) decreased from a baseline of 158.85 +/- 18.14 mg/dl to 113.55 +/- 19.38 mg/dl (p fasting blood glucose decreased from a baseline of 158.31 +/- 26.53 mg/dl to 130.55 +/- 28.31 mg/dl (p < 0.0001) (decrease of 27.76 +/- 22.91 mg/dl) at 12 weeks. In the acarbose plus metformin group postprandial blood glucose (PPBG) decreased from a baseline of 264.65 +/- 34.03 mg/dl to 173.22 +/- 31.40 mg/dl (p < 0.0001) (decrease of 91.43 +/- 28.65 mg/dl) at 12 weeks, while in the metformin group PPBG decreased from a baseline of 253.56 +/- 36.28 mg/dl to 205.36 +/- 39.49 mg/dl (p < 0.0001) (decrease of 48.20 +/- 32.72 mg/dl) at 12 weeks. In the acarbose plus metformin group glycosylated haemoglobin (HbA1c) decreased from a baseline of 9.47 +/- 0.69% to 7.71 +/- 0.85% (p < 0.0001) (% decrease of 1.76 +/- 1.11) at 12 weeks, while in the metformin group HbAlc decreased from a baseline of 9.32 +/- 0.65% to 8.26 +/- 0.68% (p < 0.0001) (% decrease of 1.06 +/- 0.66) at 12 weeks. The

  11. Comparison of a single-dose vectored thermal pulsation procedure with a 3-month course of daily oral doxycycline for moderate-to-severe meibomian gland dysfunction

    Directory of Open Access Journals (Sweden)

    Hagen KB

    2018-01-01

    Full Text Available Kerry B Hagen,1 Raman Bedi,2 Caroline A Blackie,3 Kellie J Christenson-Akagi1 1EyeHealth Northwest, Portland, OR, USA; 2Iris Advanced Eye Centre, Chandigarh, India; 3TearScience, Inc., Morrisville, NC, USA Purpose: The aim of this study was to compare the efficacy of a single bilateral 12-minute vectored thermal pulsation (VTP procedure versus daily oral doxycycline for 3 months for moderate-to-severe meibomian gland dysfunction (MGD.Methods: This prospective, randomized, parallel-group, single-masked study included 28 subjects who received either a single-dose VTP or 3 months of doxycycline treatment. At baseline and 3 months post treatment, all subjects were evaluated for the following: dry eye symptoms with a standard dry eye questionnaire (the Standard Patient Evaluation for Eye Dryness [SPEED], meibomian gland (MG function by counting the number of glands yielding liquid secretion with the MG evaluator (MGE, tear breakup time (TBUT and corneal and conjunctival staining.Results: In the VTP group, at 3 months, there was a significant improvement in MG function (4.00±1.47 to 7.73±5.53, SPEED score (11.00±3.30 to 5.42±2.15, TBUT (6.26±2.01 to 8.44±1.81, corneal staining (0.38±0.50 to 0.12±0.33 and conjunctival staining (1.69±1.93 to 0.62±0.85. In the doxycycline group, there was a significant improvement in MG function (4.63±1.41 to 10.63±5.91, SPEED score (13.42±4.17 to 9.42±5.47 and conjunctival staining (2.38±1.88 to 1.13±1.51, but the improvement in TBUT (6.90±2.56 to 7.59±2.03 and corneal staining (0.21±0.41 to 0.13±0.34 was not statistically significant (p=0.262 and p=0.414, respectively. At 3 months, SPEED score was significantly better in the VTP group (p<0.05; other parameters were comparable between the two groups.Conclusion: A single 12-minute bilateral VTP procedure was significantly more effective than the 3-month daily course of oral doxycycline at improving the dry eye symptoms secondary to MGD. A single

  12. Verification of the absorbed dose values determined with plane parallel ionization chambers in therapeutic electron beams using ferrous sulfate dosimetry

    International Nuclear Information System (INIS)

    Plaetsen, A. van der; Thierens, H.; Palmans, H.

    2000-01-01

    Absolute and relative dosimetry measurements in clinical electron beams using different detectors were performed at a Philips SL18 accelerator. For absolute dosimetry, ionization chamber measurements with the PTW Markus and PTW Roos plane parallel chambers were performed in water following the recommendations of the TRS-381 Code of Practice, using different options for chamber calibration. The dose results obtained with these ionization chambers using the electron beam calibration method were compared with the dose response of the ferrous sulphate (Fricke) chemical dosimeter. The influence of the choice of detector type on the determination of physical quantities necessary for absolute dose determination was investigated and discussed. Results for d max , R 50 and R p were in agreement within statistical uncertainties when using a diode, diamond or plane parallel chamber. The effective point of measurement for the Markus chamber is found to be shifted 0.5 mm from the front surface of the cavity. Fluence correction factors, h m , for dose determination in electron beams using a PMMA phantom were determined experimentally for both plane parallel chamber types. (author)

  13. Analgesic efficacy and safety of intravenous paracetamol (acetaminophen) administered as a 2g starting dose following third molar surgery

    DEFF Research Database (Denmark)

    Juhl, Gitte Irene; Nørholt, Sven E.; Tønnesen, Else Kirstine

    2006-01-01

    BACKGROUND: The recommended dose for intravenous (IV) paracetamol injection in adults is 1g, however pharmacokinetic and pharmacodynamic findings suggest that a better analgesia could be obtained with a 2g starting dose. METHODS: A single-centre, randomised, double-blind, placebo-controlled, 3......-parallel group study was performed to demonstrate the analgesic efficacy and safety of IV paracetamol 2g. Following third molar surgery, patients reporting moderate to severe pain received a single 15-min infusion of either IV paracetamol 2g, IV paracetamol 1g or placebo. Efficacy and safety were evaluated...... over 8h. Laboratory tests were performed before and 48h after drug administration. RESULTS: Two hundred and ninety seven patients (132=IV paracetamol 2g; 132=IV paracetamol 1g; 33=placebo) were randomised and completed the study. The summed pain relief over 6h (TOTPAR6) was significantly superior...

  14. The dose dependency of the over-dispersion of quartz OSL single grain dose distributions

    International Nuclear Information System (INIS)

    Thomsen, Kristina J.; Murray, Andrew; Jain, Mayank

    2012-01-01

    The use of single grain quartz OSL dating has become widespread over the past decade, particularly with application to samples likely to have been incompletely bleached before burial. By reducing the aliquot size to a single grain the probability of identifying the grain population most likely to have been well-bleached at deposition is maximised and thus the accuracy with which the equivalent dose can be determined is – at least in principle – improved. However, analysis of single grain dose distributions requires knowledge of the dispersion of the well-bleached part of the dose distribution. This can be estimated by measurement of a suitable analogue, e.g. a well-bleached aeolian sample, but this requires such an analogue to be available, and in addition the assumptions that the sample is in fact a) well-bleached, and b) has a similar dose rate heterogeneity to the fossil deposit. Finally, it is an implicit assumption in such analysis that any over-dispersion is not significantly dose dependent. In this study we have undertaken laboratory investigations of the dose dependency of over-dispersion using a well-bleached modern sample with an average measured dose of 36 ± 3 mGy. This sample was prepared as heated (750 °C for 1 h), bleached and untreated portions which were then given uniform gamma doses ranging from 100 mGy to 208 Gy. We show that for these samples the relative laboratory over-dispersion is not constant as a function of dose and that the over-dispersion is smaller in heated samples. We also show that the dim grains in the distributions have a greater over-dispersion than the bright grains, implying that insensitive samples will have greater values of over-dispersion than sensitive samples.

  15. Evaluation of a High Concentrated Contrast Media Injection Protocol in Combination with Low Tube Current for Dose Reduction in Coronary Computed Tomography Angiography: A Randomized, Two-center Prospective Study.

    Science.gov (United States)

    Sun, Yibo; Hua, Yanqing; Wang, Mingpeng; Mao, Dingbiao; Jin, Xiu; Li, Cheng; Shi, Kailei; Xu, Jianrong

    2017-12-01

    The study aimed to prospectively evaluate the radiation dose reduction potential and image quality (IQ) of a high-concentration contrast media (HCCM) injection protocol in combination with a low tube current (mAs) in coronary computed tomography angiography. Eighty-one consecutive patients (mean age: 62 years; 34 females; body mass index: 18-31) were included and randomized-assigned into two groups. All computed tomography (CT) examinations were performed in two groups with the same tube voltage (100 kV), flow rate of contrast medium (5.0 mL/s), and iodine dose (22.8 g). An automatic mAs and low concentration contrast medium (300 mgI/mL) were used in group A, whereas effective mAs was reduced by a factor 0.6 along with HCCM (400 mgI/mL) in group B. Radiation dose was assessed (CT dose index [CTDI vol ] and dose length product), and vessel-based objective IQ for various regions of interest (enhancement, noise, signal-to-noise ratio, and contrast-to-noise ratio), subjective IQ, noise, and motion artifacts were analyzed overall and vessel-based with a 5-point Likert scale. The CT attenuation of coronary arteries and image noise in group B were significantly higher than those in group A (ranges: 507.5-548.1 Hounsfield units vs 407.5-444.5 Hounsfield units; and 20.3 ± 8.6 vs 17.7 ± 8.0) (P ≤ 0.0166). There was no significant difference between the two groups in signal-to-noise ratio, contrast-to-noise ratio, and subjective IQ of coronary arteries (29.4-31.7, 30.0-37.0, and medium score of 5 in group A vs 29.4-32.4, 27.7-36.3, and medium score of 5 in group B, respectively, P ≥ 0.1859). Both mean CTDI vol and dose length product in group B were 58% of those of group A. HCCM combined with low tube current allows dose reduction in coronary computed tomography angiography and does not compromise IQ. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  16. On the Parallel Elliptic Single/Multigrid Solutions about Aligned and Nonaligned Bodies Using the Virtual Machine for Multiprocessors

    Directory of Open Access Journals (Sweden)

    A. Averbuch

    1994-01-01

    Full Text Available Parallel elliptic single/multigrid solutions around an aligned and nonaligned body are presented and implemented on two multi-user and single-user shared memory multiprocessors (Sequent Symmetry and MOS and on a distributed memory multiprocessor (a Transputer network. Our parallel implementation uses the Virtual Machine for Muli-Processors (VMMP, a software package that provides a coherent set of services for explicitly parallel application programs running on diverse multiple instruction multiple data (MIMD multiprocessors, both shared memory and message passing. VMMP is intended to simplify parallel program writing and to promote portable and efficient programming. Furthermore, it ensures high portability of application programs by implementing the same services on all target multiprocessors. The performance of our algorithm is investigated in detail. It is seen to fit well the above architectures when the number of processors is less than the maximal number of grid points along the axes. In general, the efficiency in the nonaligned case is higher than in the aligned case. Alignment overhead is observed to be up to 200% in the shared-memory case and up to 65% in the message-passing case. We have demonstrated that when using VMMP, the portability of the algorithms is straightforward and efficient.

  17. Glycemic control, compliance, and satisfaction for diabetic gravidas in centering group care.

    Science.gov (United States)

    Parikh, Laura I; Jelin, Angie C; Iqbal, Sara N; Belna, Sarah L; Fries, Melissa H; Patel, Misbah; Desale, Sameer; Ramsey, Patrick S

    2017-05-01

    To determine if diabetic gravidas enrolled in Centering® group care have improved glycemic control compared to those attending standard prenatal care. To compare compliance and patient satisfaction between the groups. We conducted a prospective cohort study of diabetics enrolled in centering group care from October 2013 to December 2015. Glycemic control, compliance and patient satisfaction (five-point Likert scale) were evaluated. Student's t-test, Chi-Square and mixed effects model were used to compare outcomes. We compared 20 patients in centering to 28 standard prenatal care controls. Mean fasting blood sugar was lower with centering group care (91.0 versus 105.5 mg/dL, p =0.017). There was no difference in change in fasting blood sugar over time between the two groups (p = 0.458). The percentage of time patients brought their blood glucose logs did not differ between the centering group and standard prenatal care (70.7 versus 73.9%, p = 0.973). Women in centering group care had better patient satisfaction scores for "ability to be seen by a physician" (5 versus 4, p = 0.041) and "time in waiting room" (5 versus 4, p =0.001). Fasting blood sugar was lower for patients in centering group care. Change in blood sugar over time did not differ between groups. Diabetic gravidas enrolled in centering group care report improved patient satisfaction.

  18. Single-shot magnetic resonance spectroscopic imaging with partial parallel imaging.

    Science.gov (United States)

    Posse, Stefan; Otazo, Ricardo; Tsai, Shang-Yueh; Yoshimoto, Akio Ernesto; Lin, Fa-Hsuan

    2009-03-01

    A magnetic resonance spectroscopic imaging (MRSI) pulse sequence based on proton-echo-planar-spectroscopic-imaging (PEPSI) is introduced that measures two-dimensional metabolite maps in a single excitation. Echo-planar spatial-spectral encoding was combined with interleaved phase encoding and parallel imaging using SENSE to reconstruct absorption mode spectra. The symmetrical k-space trajectory compensates phase errors due to convolution of spatial and spectral encoding. Single-shot MRSI at short TE was evaluated in phantoms and in vivo on a 3-T whole-body scanner equipped with a 12-channel array coil. Four-step interleaved phase encoding and fourfold SENSE acceleration were used to encode a 16 x 16 spatial matrix with a 390-Hz spectral width. Comparison with conventional PEPSI and PEPSI with fourfold SENSE acceleration demonstrated comparable sensitivity per unit time when taking into account g-factor-related noise increases and differences in sampling efficiency. LCModel fitting enabled quantification of inositol, choline, creatine, and N-acetyl-aspartate (NAA) in vivo with concentration values in the ranges measured with conventional PEPSI and SENSE-accelerated PEPSI. Cramer-Rao lower bounds were comparable to those obtained with conventional SENSE-accelerated PEPSI at the same voxel size and measurement time. This single-shot MRSI method is therefore suitable for applications that require high temporal resolution to monitor temporal dynamics or to reduce sensitivity to tissue movement.

  19. Image quality and absorbed dose comparison of single- and dual-source cone-beam computed tomography.

    Science.gov (United States)

    Miura, Hideharu; Ozawa, Shuichi; Okazue, Toshiya; Kawakubo, Atsushi; Yamada, Kiyoshi; Nagata, Yasushi

    2018-04-17

    Dual-source cone-beam computed tomography (DCBCT) is currently available in the Vero4DRT image-guided radiotherapy system. We evaluated the image quality and absorbed dose for DCBCT and compared the values with those for single-source CBCT (SCBCT). Image uniformity, Hounsfield unit (HU) linearity, image contrast, and spatial resolution were evaluated using a Catphan phantom. The rotation angle for acquiring SCBCT and DCBCT images is 215° and 115°, respectively. The image uniformity was calculated using measurements obtained at the center and four peripheral positions. The HUs of seven materials inserted into the phantom were measured to evaluate HU linearity and image contrast. The Catphan phantom was scanned with a conventional CT scanner to measure the reference HU for each material. The spatial resolution was calculated using high-resolution pattern modules. Image quality was analyzed using ImageJ software ver. 1.49. The absorbed dose was measured using a 0.6-cm 3 ionization chamber with a 16-cm-diameter cylindrical phantom, at the center and four peripheral positions of the phantom, and calculated using weighted cone-beam CT dose index (CBCTDI w ). Compared with that of SCBCT, the image uniformity of DCBCT was slightly reduced. A strong linear correlation existed between the measured HU for DCBCT and the reference HU, although the linear regression slope was different from that of the reference HU. DCBCT had poorer image contrast than did SCBCT, particularly with a high-contrast material. There was no significant difference between the spatial resolutions of SCBCT and DCBCT. The absorbed dose for DCBCT was higher than that for SCBCT, because in DCBCT, the two x-ray projections overlap between 45° and 70°. We found that the image quality was poorer and the absorbed dose was higher for DCBCT than for SCBCT in the Vero4DRT. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of

  20. Single- and multiple-dose pharmacokinetics of biphasic immediate-release/extended-release hydrocodone bitartrate/acetaminophen (MNK-155 compared with immediate-release hydrocodone bitartrate/ibuprofen and immediate-release tramadol HCl/acetaminophen

    Directory of Open Access Journals (Sweden)

    Devarakonda K

    2015-09-01

    Full Text Available Krishna Devarakonda,1 Kenneth Kostenbader,2 Michael J Giuliani,3 Jim L Young41Department of Clinical Pharmacology, Mallinckrodt Pharmaceuticals, 2Mallinckrodt Pharmaceuticals, 3Research and Development, Mallinckrodt Pharmaceuticals, 4Department of Clinical Affairs and Program Management, Mallinckrodt Pharmaceuticals, Hazelwood, MO, USAObjective: To characterize the single-dose and steady-state pharmacokinetics (PK of biphasic immediate-release/extended-release hydrocodone bitartrate/acetaminophen (IR/ER HB/APAP, IR HB/ibuprofen, and IR tramadol HCl/APAP.Methods: In this single-center, open-label, randomized, four-period crossover study, healthy participants received four treatments under fasted conditions: 1 a single dose of two IR/ER HB/APAP 7.5/325 mg tablets (15/650 mg total dose on day 1, followed by two tablets every 12 hours (q12h beginning on day 3; 2 a single dose of IR HB/ibuprofen 15/400 mg (divided as one 7.5/200 mg tablet at hour 0 and 6, followed by one tablet every 6 hours (q6h beginning on day 3; 3 a single dose of IR tramadol HCl/APAP 75/650 mg (divided as one 37.5/325 mg tablet at hour 0 and 6, followed by one tablet q6h beginning on day 3; and 4 a single dose of three IR/ER HB/APAP 7.5/325 mg tablets (22.5/975 mg total dose on day 1, a three-tablet initial dose at 48 hours followed by two-tablet doses q12h beginning on day 3. Hydrocodone and APAP single-dose and steady-state PK were assessed. Adverse events were monitored.Results: The PK analysis was carried out on 29 of 48 enrolled participants who completed all treatment periods. Single-dose hydrocodone exposure was similar for IR/ER HB/APAP 22.5/975 mg and IR HB/ibuprofen 15/400 mg; time to maximum observed plasma concentration was shorter and half-life was longer for IR/ER HB/APAP (22.5/975 mg and 15/650 mg vs IR HB/ibuprofen. Single-dose APAP exposure was similar for IR/ER HB/APAP 15/650 mg and IR tramadol HCl/APAP 75/650 mg. Steady-state hydrocodone and APAP exposures

  1. Comparison between a single dose of goserelin (depot) and multiple daily doses of leuprolide acetate for pituitary suppression in IVF treatment: a clinical endocrinological study of the ovarian response.

    Science.gov (United States)

    Geber, Selmo; Sales, Liana; Sampaio, Marcos A C

    2002-07-01

    Compare the efficacy and safety of two different GnRHa, used for pituitary suppression in IVF cycles. A total of 292 patients using depot goserelin (Group 1) and 167 using daily leuprolide acetate (Group 2) were compared. Days required to achieve pituitary function suppression, duration of ovarian stimulation, total dose of HMG, number of aspirated follicles, number of oocytes retrieved, and presence of functional ovarian cyst were analyzed. The time taken to achieve downregulation was similar. The mean number of ampoules used for superovulation was higher in Group 1; however, this difference was observed only for patients >40 years old that started GnRHa in the follicular phase. There was no difference between the two groups in the duration of superovulation, in the number of follicles aspirated, and the number of oocytes retrieved. In the group of patients with >40 years the incidence of ovarian cysts was higher in Group 2. Both routes of GnRHa have similar effects for pituitary suppression and ovulation induction in assisted reproductive technology. Therefore the long-acting GnRHa is an excellent option, as only a single subcutaneous dose is necessary, decreasing the risk of the patient to forget its use and, most important, it does not interfere in the patient's quality of life.

  2. Effective dose comparison between stitched and single FOV in CBCT protocols for complete dental arcade

    International Nuclear Information System (INIS)

    Soares, Maria Rosangela; Batista, Wilson Otto; Antonio, Patricia Lara de; Caldas, Linda V.E.; Maia, Ana F.

    2015-01-01

    Objective: The objective of this study was to assess and compare protocols with a single field of view and multiple stitched field of view with a similar clinical purpose by means of effective dose value. Materials and methods: Measurements of absorbed dose were performed with thermoluminescent dosemeters inserted in the position of organs/tissues of a female anthropomorphic phantom and from these values the effective dose was calculated, utilizing weighting factor tissue-ICRP 103 (2007). Results: The results obtained in this study for effective dose are within the range of 43.1 µSv and 111.5 µSv for equipment using protocols with single FOV and in the range of 44.5 µSv and 236.2 µSv for equipments that using protocols with stitched field of view. Conclusions: In terms of the value of effective dose, stitched FOV protocols do not have any advantage over the single field of view protocols. This results suggest the necessity for knowledge of the exposure parameters and effective dose values associated with each image protocol. - Highlights: • The study relies on the comparison of two protocols with similar goals of CBCT: stitched protocols and single protocols. • The stitched FOV protocol is more specific and it is good option when want imaging only of some dental units. • In relation the effective dose, single FOV protocols presents advantage over the stitched FOV protocols. • Know the exposure parameters and effective dose values associated with each image protocol is necessity for request the best CBCT tomographic image

  3. A comparison of simple and realistic eye models for calculation of fluence to dose conversion coefficients in a broad parallel beam incident of protons

    International Nuclear Information System (INIS)

    Sakhaee, Mahmoud; Vejdani-Noghreiyan, Alireza; Ebrahimi-Khankook, Atiyeh

    2015-01-01

    Radiation induced cataract has been demonstrated among people who are exposed to ionizing radiation. To evaluate the deterministic effects of ionizing radiation on the eye lens, several papers dealing with the eye lens dose have been published. ICRP Publication 103 states that the lens of the eye may be more radiosensitive than previously considered. Detailed investigation of the response of the lens showed that there are strong differences in sensitivity to ionizing radiation exposure with respect to cataract induction among the tissues of the lens of the eye. This motivated several groups to look deeper into issue of the dose to a sensitive cell population within the lens, especially for radiations with low energy penetrability that have steep dose gradients inside the lens. Two sophisticated mathematical models of the eye including the inner structure have been designed for the accurate dose estimation in recent years. This study focuses on the calculations of the absorbed doses of different parts of the eye using the stylized models located in UF-ORNL phantom and comparison with the data calculated with the reference computational phantom in a broad parallel beam incident of protons with energies between 20 MeV and 10 GeV. The obtained results indicate that the total lens absorbed doses of reference phantom has good compliance with those of the more sensitive regions of stylized models. However, total eye absorbed dose of these models greatly differ with each other for lower energies. - Highlights: • The validation of reference data for the eye was studied for proton exposures. • Two real mathematical models of the eye were imported into the UF-ORNL phantom. • Fluence to dose conversion coefficients were calculated for different eye sections. • Obtained Results were compared with that of assessed by ICRP adult male phantom

  4. Single versus Two-Site Phacoemulsification and Mitomycin-C Trabeculectomy

    Directory of Open Access Journals (Sweden)

    Alireza Baradaran-Rafiee

    2008-11-01

    Full Text Available

    PURPOSE: To compare the outcomes of single-site versus two-site mitomycin-C (MMC augmented phacotrabeculectomy. METHODS: This matched randomized clinical trial included 34 eyes of 30 patients with visually significant cataracts and poorly controlled glaucoma. Equal numbers of eyes were randomly assigned to the single-site and two-site groups. In the single-site approach, phacoemulsification was performed under a superior scleral tunnel followed by trabeculectomy. The two-site approach included a temporal clear corneal phaco-emulsification combined with a separate superior trabeculectomy. MMC 0.2 mg/ml was similarly applied for one minute in both groups. RESULTS: Patients were followed for a mean period of 13±1.4 (range, 12 to 15 months. Mean best corrected visual acuity one year after surgery was 0.6±0.4 LogMAR in the single-site group and 0.4±0.28 LogMAR in the two-site group (P=0.12. In the single-site group, mean preoperative intraocular pressure (IOP was 26.4±6.6 mmHg which was decreased to 14.8±2.5 mmHg, one year after the operation (P < 0.001. Corresponding figures for the two-site group were 22.9±3.3 and 13.6±1.7 mmHg respectively (P < 0.001. At final follow up no significant difference in IOP existed between the study groups. Mean number of anti-glaucoma medications was 0.06±0.24 in the two-site group vs 0

  5. Oxidative Addition and Reductive Elimination at Main-Group Element Centers.

    Science.gov (United States)

    Chu, Terry; Nikonov, Georgii I

    2018-04-11

    Oxidative addition and reductive elimination are key steps in a wide variety of catalytic reactions mediated by transition-metal complexes. Historically, this reactivity has been considered to be the exclusive domain of d-block elements. However, this paradigm has changed in recent years with the demonstration of transition-metal-like reactivity by main-group compounds. This Review highlights the substantial progress achieved in the past decade for the activation of robust single bonds by main-group compounds and the more recently realized activation of multiple bonds by these elements. We also discuss the significant discovery of reversible activation of single bonds and distinct examples of reductive elimination at main-group element centers. The review consists of three major parts, starting with oxidative addition of single bonds, proceeding to cleavage of multiple bonds, and culminated by the discussion of reversible bond activation and reductive elimination. Within each subsection, the discussion is arranged according to the type of bond being cleaved or formed and considers elements from the left to the right of each period and down each group of the periodic table. The majority of results discussed in this Review come from the past decade; however, earlier reports are also included to ensure completeness.

  6. Protective effect of hypoxia in the ram testis during single and split-dose X-irradiation

    International Nuclear Information System (INIS)

    Vliet, J. van; Wensing, C.J.G.; Bootsma, A.L.; Peperzeel, H.A. van; Schipper, J.

    1988-01-01

    Spertogonial stem-cell survival in the ram was studied after single (6Gy) and split-dose X-irradiation both under normal and hypoxic conditions. Hypoxia was induced by inflation of an occluder implanted around the testicular artery. The occluders were inflated about 10 min before irradiation and deflated immediately after. Stem-cell survival was measured at 5 or 7 weeks after irradiation by determination of the Repopulation Index (RI) in histological testis sections. The RI-values after fractionated irradiation were only half those after single dose irradiation. Hypoxia had a protective effect on the stem-cell survival. After split-dose irradiation under hypoxic conditions two times more stem cells survived than under normal oxic conditions; the RI-values increased from 34% (oxic) to 68% (hypoxic). This effect of hypoxia was also found after single dose irradiation where the RI-values increased from 68% (oxic) to 84% (hypoxic). The development of the epithelium in repopulated tubules was also studied. Under hypoxia, a significantly higher fraction of tubules with complete epithelium was found after single (38 vs. 4%) as well as after split-dose irradiation (12 vs. 0%)

  7. Effects of a preovulatory single low dose of mifepristone on ovarian function

    NARCIS (Netherlands)

    van der Stege, Jolande G.; Pahl-van Beest, Elske H.; Beerthuizen, Rob J. C. M.; van Lunsen, Rik H. W.; Scholten, Piet C.; Bogchelman, Dick H.

    Objectives To investigate the effect of a single low dose of mifepristone on ovarian function, when administered in the preovulatory period. Methods Healthy women with regular menstrual cycles were studied during two consecutive menstrual cycles. Either mifepristone or placebo was given in a

  8. Dual-volume excitation and parallel reconstruction for J-difference-edited MR spectroscopy

    DEFF Research Database (Denmark)

    Oeltzschner, Georg; Puts, Nicolaas A J; Chan, Kimberly L

    2017-01-01

    successfully reconstructed with a mean in vivo g-factor of 1.025 (typical voxel-center separation: 7-8 cm). MEGA-PRIAM experiments showed higher signal-to-noise ratio than sequential single-voxel experiments of the same total duration (mean improvement 1.38 ± 0.24). CONCLUSIONS: Simultaneous acquisition of J......PURPOSE: To develop J-difference editing with parallel reconstruction in accelerated multivoxel (PRIAM) for simultaneous measurement in two separate brain regions of γ-aminobutyric acid (GABA) or glutathione. METHODS: PRIAM separates signals from two simultaneously excited voxels using receiver...

  9. Efficacy of Single-dose and 2-dose Intravenous Administration of Ramosetron in Preventing Postoperative Nausea and Vomiting After Laparoscopic Gynecologic Operation: A Randomized, Double-blind, Placebo-controlled, Phase 2 Trial.

    Science.gov (United States)

    Lee, Banghyun; Kim, Kidong; Suh, Dong Hoon; Shin, Hyun-Jung; No, Jae Hong; Lee, Jung Ryeol; Jee, Byung Chul; Hwang, Jung Won; Do, Sang Hwan; Kim, Yong Beom

    2017-06-01

    This randomized trial investigated whether a 2-dose administration of intravenous ramosetron (5-hydroxytryptamine type 3 receptor antagonist) is more effective than a single-dose administration in preventing postoperative nausea and vomiting (PONV) in 89 patients who were scheduled to undergo laparoscopic operation for benign gynecologic diseases and to receive intravenous patient-controlled analgesia for relief of postoperative pain. After assignment at a ratio of 1:1, intravenous ramosetron (0.3 mg) was initially administered at the end of skin closure in all patients. Thereafter, ramosetron (0.3 mg) and placebo were administered to the study and control groups, respectively, at 4 hours after the operation. The baseline and operative characteristics were similar between the groups. The incidence of PONV during the 24-hour period after operation which was assessed as the primary endpoint did not differ between the groups. No serious adverse events occurred in either group. A 2-dose administration of intravenous ramosetron may not be superior to a single-dose administration in preventing PONV in patients undergoing laparoscopic operation for benign gynecologic diseases.

  10. The Effect of Nicotine Administration on Physical and Psychological Signs of Withdrawal Syndrome Induced by Single or Frequent Doses of Morphine in Rats

    Directory of Open Access Journals (Sweden)

    Mohammad Allahtavakoli

    2012-07-01

    Full Text Available Introduction. Morphine addiction and morphine withdrawal syndrome are the two main problems of today’s human society. The present study has investigated the effects of nicotine on the strength of physical and psychological dependency in single and repeated doses morphine administrated rats. Materials and methods. Male Wistar rats were subjected to morphine consumption with single or frequent dose protocols. In the single dose protocol, rats received only one dose of morphine and 24hrs later they also received one dose of nicotine 30 min prior to injection of naloxone. In the repeated dose protocol, rats received incremental doses of morphine for 7 days and 24hr after the last dose (the 8th day were given naloxone. However, the nicotine regimen of this group was injected 15 min before the morphine injection, for 4 days, from the 4th to the 7th day. Five minutes after naloxone injection, each rat′s behavior was captured for 30 min, and then physical and psychological signs of withdrawal syndrome were recorded. Data were analyzed by ANOVA followed by Tukey tests and p<0.05 was considered as significant difference. Findings. Results showed that the injection of frequent and single doses of morphine lead to morphine dependency. In single dose protocol, nicotine consumption attenuated the signs of withdrawal syndrome, especially weight of excrement and total withdrawal score. In frequent dose protocol, in addition to these effects, nicotine induced weight loss and place aversion. Conclusion. The inhibitory effects of nicotine on signs of withdrawal syndrome may involve a dopaminergic portion of the central nervous system and is mediated by central nicotinic receptors. There is also a cross-dependence between nicotine and morphine.

  11. Quantum chaos in the two-center shell model

    Energy Technology Data Exchange (ETDEWEB)

    Milek, B; Noerenberg, W; Rozmej, P [Gesellschaft fuer Schwerionenforschung m.b.H., Darmstadt (Germany, F.R.)

    1989-11-01

    Within an axially symmetric two-center shell model single-particle levels with {Omega}=1/2 are analyzed with respect to their level-spacing distributions and avoided level crossings as functions of the shape parameters. Only for shapes sufficiently far from any additional symmetry, ideal Wigner distributions are found as signature for quantum chaos. (orig.).

  12. Quantum chaos in the two-center shell model

    Energy Technology Data Exchange (ETDEWEB)

    Milek, B; Noerenberg, W; Rozmej, P

    1989-03-01

    Within an axially symmetric two-center shell model single-particle levels with ..cap omega.. = 1/2 are analyzed with respect to their level-spacing distributions and avoided level crossings as functions of the shape parameters. Only for shapes sufficiently far from any additional symmetry, ideal Wigner distributions are found as signature for quantum chaos.

  13. Optimizing trial design in pharmacogenetics research: comparing a fixed parallel group, group sequential, and adaptive selection design on sample size requirements.

    Science.gov (United States)

    Boessen, Ruud; van der Baan, Frederieke; Groenwold, Rolf; Egberts, Antoine; Klungel, Olaf; Grobbee, Diederick; Knol, Mirjam; Roes, Kit

    2013-01-01

    Two-stage clinical trial designs may be efficient in pharmacogenetics research when there is some but inconclusive evidence of effect modification by a genomic marker. Two-stage designs allow to stop early for efficacy or futility and can offer the additional opportunity to enrich the study population to a specific patient subgroup after an interim analysis. This study compared sample size requirements for fixed parallel group, group sequential, and adaptive selection designs with equal overall power and control of the family-wise type I error rate. The designs were evaluated across scenarios that defined the effect sizes in the marker positive and marker negative subgroups and the prevalence of marker positive patients in the overall study population. Effect sizes were chosen to reflect realistic planning scenarios, where at least some effect is present in the marker negative subgroup. In addition, scenarios were considered in which the assumed 'true' subgroup effects (i.e., the postulated effects) differed from those hypothesized at the planning stage. As expected, both two-stage designs generally required fewer patients than a fixed parallel group design, and the advantage increased as the difference between subgroups increased. The adaptive selection design added little further reduction in sample size, as compared with the group sequential design, when the postulated effect sizes were equal to those hypothesized at the planning stage. However, when the postulated effects deviated strongly in favor of enrichment, the comparative advantage of the adaptive selection design increased, which precisely reflects the adaptive nature of the design. Copyright © 2013 John Wiley & Sons, Ltd.

  14. Variable dose rate single-arc IMAT delivered with a constant dose rate and variable angular spacing

    International Nuclear Information System (INIS)

    Tang, Grace; Earl, Matthew A; Yu, Cedric X

    2009-01-01

    Single-arc intensity-modulated arc therapy (IMAT) has gained worldwide interest in both research and clinical implementation due to its superior plan quality and delivery efficiency. Single-arc IMAT techniques such as the Varian RapidArc(TM) deliver conformal dose distributions to the target in one single gantry rotation, resulting in a delivery time in the order of 2 min. The segments in these techniques are evenly distributed within an arc and are allowed to have different monitor unit (MU) weightings. Therefore, a variable dose-rate (VDR) is required for delivery. Because the VDR requirement complicates the control hardware and software of the linear accelerators (linacs) and prevents most existing linacs from delivering IMAT, we propose an alternative planning approach for IMAT using constant dose-rate (CDR) delivery with variable angular spacing. We prove the equivalence by converting VDR-optimized RapidArc plans to CDR plans, where the evenly spaced beams in the VDR plan are redistributed to uneven spacing such that the segments with larger MU weighting occupy a greater angular interval. To minimize perturbation in the optimized dose distribution, the angular deviation of the segments was restricted to ≤± 5 deg. This restriction requires the treatment arc to be broken into multiple sectors such that the local MU fluctuation within each sector is reduced, thereby lowering the angular deviation of the segments during redistribution. The converted CDR plans were delivered with a single gantry sweep as in the VDR plans but each sector was delivered with a different value of CDR. For four patient cases, including two head-and-neck, one brain and one prostate, all CDR plans developed with the variable spacing scheme produced similar dose distributions to the original VDR plans. For plans with complex angular MU distributions, the number of sectors increased up to four in the CDR plans in order to maintain the original plan quality. Since each sector was

  15. Radiobiological responses for two cell lines following continuous low dose-rate (CLDR) and pulsed dose rate (PDR) brachytherapy

    International Nuclear Information System (INIS)

    Hanisch, Per Henrik; Furre, Torbjoern; Olsen, Dag Rune; Pettersen, Erik O.

    2007-01-01

    The iso-effective irradiation of continuous low-dose-rate (CLDR) irradiation was compared with that of various schedules of pulsed dose rate (PDR) irradiation for cells of two established human lines, T-47D and NHIK 3025. Complete single-dose response curves were obtained for determination of parameters α and β by fitting of the linear quadratic formula. Sublethal damage repair constants μ and T 1/2 were determined by split-dose recovery experiments. On basis of the acquired parameters of each cell type the relative effectiveness of the two regimens of irradiation (CLDR and PDR) was calculated by use of Fowler's radiobiological model for iso-effect irradiation for repeated fractions of dose delivered at medium dose rates. For both cell types the predicted and observed relative effectiveness was compared at low and high iso-effect levels. The results indicate that the effect of PDR irradiation predicted by Fowler's model is equal to that of CLDR irradiation for both small and large doses with T-47D cells. With NHIK 3025 cells PDR irradiation induces a larger effect than predicted by the model for small doses, while it induces the predicted effect for high doses. The underlying cause of this difference is unclear, but cell-cycle parameters, like G2-accumulation is tested and found to be the same for the two cell lines

  16. Clinical application of AcMAR (accelerated multiple-arc radiotherapy) for head and neck tumors. Results of a randomized, two-dose study in Kitami Red-Cross General Hospital

    International Nuclear Information System (INIS)

    Arimoto, Takuro; Yamazaki, Akira; Yonesaka, Akio; Matsuzawa, Tooru; Kanai, Naoki

    2003-01-01

    Enhanced acute mucositis is the limiting factor for accelerated, hyperfractionated radiotherapy in head and neck (H and N) squamous cell carcinomas (SCCs). We have developed a simple, new form of conformal radiotherapy, accelerated multiple arc radiotherapy (AcMAR), which covers the target volume by combined, segmental, and rotational arc fields. Two to three rotational fields were placed with CT guidance, each covering the primary tumor and lymph nodes separately. The optimal inter-isocenter distance was determined by 3D dose calculation. The surface area of oro-pharyngeal mucosa irradiated by more than a 50% dose by this method was reduced by 37-73% compared to that with a conventional parallel opposing technic. Dose searching, randomized two-dose study was initiated in Kitami Red-cross General Hospital (KRCGH) in January 1995, and 101 patients were registered and completed AcMAR in Oct 2000. All the patients were followed for up to 96 months (24-96 mo, median 48 mo) at the time of analysis. Fifty-one out of 101 patients were Stage III (17) and IV (34). Primary site of tumors were; 38 larynx, 25 oropharynx, 15 hypopharynx, 13 oral cavity, and 10 other miscellaneous sites. Patients were randomly allocated either to 60 Gy/24 fr/bid/3 wks to gross tumor volume (GTV) (Group A), or 66 Gy/33 fr/bid/4 wks to GTV (Group B). Forty Gy/16 fr/bid/2 wks was given to the volume of prophylactic'' irradiation in both groups of patients. Results were as follows: All the patients, except for one, completed AcMAR without treatment interruption. Acute mucositis at the site of high-dose irradiation was intense; 72% of Group A and 62.5% of Group B experienced World Health Organization (WHO) Grade 3 (confluent) mucositis focally. Fifty-one out of 53 in Group A and 48/48 in Group B, however, could maintain oral food intake (WHO Grade 1 or 2) even at the peak of their mucositis, because of the limited area of severe mucositis. With regard to late morbidity, however, 6/46 (followed >24 mo

  17. Comparison of single-grain and small-aliquot OSL dose estimates in < 3000 years old river sediments from South India

    DEFF Research Database (Denmark)

    Thomas, P.J.; Jain, M.; Juyal, N.

    2005-01-01

    We report on OSL dose distributions derived from small-aliquot and single grains of quartz in young fluvial sediments sampled from the Penner River basin, South India. The single-grain dose distributions suggest that 13 out of 19 samples were well bleached. In many well-bleached samples, there wa......We report on OSL dose distributions derived from small-aliquot and single grains of quartz in young fluvial sediments sampled from the Penner River basin, South India. The single-grain dose distributions suggest that 13 out of 19 samples were well bleached. In many well-bleached samples......, there was an underestimation in the single-aliquot dose estimates as compared to those from the single grain-the difference between average dose estimates determined by the two methods ranged from similar to 1% to 31%. Such a dose underestimation was not detectable in poorly bleached samples. Various possible reasons...... perhaps be one of the reasons; this may occur because the stimulation wavelength affects the proportion of the medium and slow components in the initial signal. (c) 2004 Elsevier Ltd. All rights reserved....

  18. Two-fluid and parallel compressibility effects in tokamak plasmas

    International Nuclear Information System (INIS)

    Sugiyama, L.E.; Park, W.

    1998-01-01

    The MHD, or single fluid, model for a plasma has long been known to provide a surprisingly good description of much of the observed nonlinear dynamics of confined plasmas, considering its simple nature compared to the complexity of the real system. On the other hand, some of the supposed agreement arises from the lack of the detailed measurements that are needed to distinguish MHD from more sophisticated models that incorporate slower time scale processes. At present, a number of factors combine to make models beyond MHD of practical interest. Computational considerations still favor fluid rather than particle models for description of the full plasma, and suggest an approach that starts from a set of fluid-like equations that extends MHD to slower time scales and more accurate parallel dynamics. This paper summarizes a set of two-fluid equations for toroidal (tokamak) geometry that has been developed and tested as the MH3D-T code [1] and some results from the model. The electrons and ions are described as separate fluids. The code and its original MHD version, MH3D [2], are the first numerical, initial value models in toroidal geometry that include the full 3D (fluid) compressibility and electromagnetic effects. Previous nonlinear MHD codes for toroidal geometry have, in practice, neglected the plasma density evolution, on the grounds that MHD plasmas are only weakly compressible and that the background density variation is weaker than the temperature variation. Analytically, the common use of toroidal plasma models based on aspect ratio expansion, such as reduced MHD, has reinforced this impression, since this ordering reduces plasma compressibility effects. For two-fluid plasmas, the density evolution cannot be neglected in principle, since it provides the basic driving energy for the diamagnetic drifts of the electrons and ions perpendicular to the magnetic field. It also strongly influences the parallel dynamics, in combination with the parallel thermal

  19. Ocular Pharmacokinetics of Dorzolamide and Brinzolamide After Single and Multiple Topical Dosing: Implications for Effects on Ocular Blood FlowS⃞

    Science.gov (United States)

    Kadam, Rajendra S.; Jadhav, Gajanan; Ogidigben, Miller

    2011-01-01

    Ophthalmic carbonic anhydrase inhibitors have been shown to improve retinal and optic nerve blood flow. However, the relative tissue distributions of commercially available carbonic anhydrase inhibitors to the optic nerve are not known. The objective of this study was to compare the ocular pharmacokinetics and tissue distribution profiles of dorzolamide and brinzolamide after single and multiple topical applications. Pigmented rabbits were treated with single or multiple topical administrations of 30 μl of Trusopt (dorzolamide hydrochloride ophthalmic solution, 2%) to one eye and 30 μl of Azopt (brinzolamide ophthalmic suspension, 1%) to the other eye. Rabbits were euthanized at 10 predetermined time intervals over a period of 24 h, and ocular tissues and plasma samples were collected. For multiple dosing, rabbits were dosed twice per day with an 8-h interval between two doses, groups of rabbits were euthanized at 7, 14, and 21 days at 1 h after the last dose, and ocular tissues and plasma samples were collected. Drug levels in tissue samples were measured using liquid chromatography/tandem mass spectrometry. Pharmacokinetic parameters (Cmax, Tmax, and AUC0–24) were estimated by noncompartmental analysis. After a single dose, dorzolamide delivery (AUC0–24) to the aqueous humor, anterior sclera, posterior sclera, anterior retina, posterior retina, anterior vitreous, and optic nerve was 2-, 7-, 2.6-, 1.4-, 1.9-, 1.2-, and 9-fold higher than those of brinzolamide. Cmax was 2- to 5-fold higher for dorzolamide than that of brinzolamide in all of the ocular tissue. After multiple dosing, dorzolamide levels in the aqueous humor, sclera, retina, vitreous humor, and optic nerve were higher than those of brinzolamide, but statistical significance was achieved only with aqueous humor, vitreous humor, and optic nerve. Dorzolamide levels in the aqueous humor, anterior vitreous, posterior vitreous, and optic nerve were 1.4- to 3.2-, 2.4- to 2.7-, 2.2- to 4.5-, and 2.4- to

  20. Comparison of single-grain and small-aliquot OSL dose estimates in <3000 years old river sediments from South India

    International Nuclear Information System (INIS)

    Thomas, P.J.; Jain, M.; Juyal, N.; Singhvi, A.K.

    2005-01-01

    We report on OSL dose distributions derived from small-aliquot and single grains of quartz in young fluvial sediments sampled from the Penner River basin, South India. The single-grain dose distributions suggest that 13 out of 19 samples were well bleached. In many well-bleached samples, there was an underestimation in the single-aliquot dose estimates as compared to those from the single grain-the difference between average dose estimates determined by the two methods ranged from ∼1% to 31%. Such a dose underestimation was not detectable in poorly bleached samples. Various possible reasons for the discrepancy between single-grain and small-aliquot dose estimates are discussed. Although there is no satisfactory explanation for this discrepancy, we speculate that the difference in the stimulation wavelengths, 470+/-30nm in the case of single-aliquot and 532nm in the case of single grains, could perhaps be one of the reasons; this may occur because the stimulation wavelength affects the proportion of the medium and slow components in the initial signal

  1. Shared memory parallelism for 3D cartesian discrete ordinates solver

    International Nuclear Information System (INIS)

    Moustafa, S.; Dutka-Malen, I.; Plagne, L.; Poncot, A.; Ramet, P.

    2013-01-01

    This paper describes the design and the performance of DOMINO, a 3D Cartesian SN solver that implements two nested levels of parallelism (multi-core + SIMD - Single Instruction on Multiple Data) on shared memory computation nodes. DOMINO is written in C++, a multi-paradigm programming language that enables the use of powerful and generic parallel programming tools such as Intel TBB and Eigen. These two libraries allow us to combine multi-thread parallelism with vector operations in an efficient and yet portable way. As a result, DOMINO can exploit the full power of modern multi-core processors and is able to tackle very large simulations, that usually require large HPC clusters, using a single computing node. For example, DOMINO solves a 3D full core PWR eigenvalue problem involving 26 energy groups, 288 angular directions (S16), 46*10 6 spatial cells and 1*10 12 DoFs within 11 hours on a single 32-core SMP node. This represents a sustained performance of 235 GFlops and 40.74% of the SMP node peak performance for the DOMINO sweep implementation. The very high Flops/Watt ratio of DOMINO makes it a very interesting building block for a future many-nodes nuclear simulation tool. (authors)

  2. Experience of micromultileaf collimator linear accelerator based single fraction stereotactic radiosurgery: Tumor dose inhomogeneity, conformity, and dose fall off

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Linda X.; Garg, Madhur; Lasala, Patrick; Kim, Mimi; Mah, Dennis; Chen, Chin-Cheng; Yaparpalvi, Ravindra; Mynampati, Dinesh; Kuo, Hsiang-Chi; Guha, Chandan; Kalnicki, Shalom [Department of Radiation Oncology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, New York 10461 (United States); Department of Neurosurgery, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, New York 10461 (United States); Department of Epidemiology and Population Health, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, New York 10461 (United States); Department of Radiation Oncology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, New York 10461 (United States)

    2011-03-15

    Purpose: Sharp dose fall off outside a tumor is essential for high dose single fraction stereotactic radiosurgery (SRS) plans. This study explores the relationship among tumor dose inhomogeneity, conformity, and dose fall off in normal tissues for micromultileaf collimator (mMLC) linear accelerator (LINAC) based cranial SRS plans. Methods: Between January 2007 and July 2009, 65 patients with single cranial lesions were treated with LINAC-based SRS. Among them, tumors had maximum diameters {<=}20 mm: 31; between 20 and 30 mm: 21; and >30 mm: 13. All patients were treated with 6 MV photons on a Trilogy linear accelerator (Varian Medical Systems, Palo Alto, CA) with a tertiary m3 high-resolution mMLC (Brainlab, Feldkirchen, Germany), using either noncoplanar conformal fixed fields or dynamic conformal arcs. The authors also created retrospective study plans with identical beam arrangement as the treated plan but with different tumor dose inhomogeneity by varying the beam margins around the planning target volume (PTV). All retrospective study plans were normalized so that the minimum PTV dose was the prescription dose (PD). Isocenter dose, mean PTV dose, RTOG conformity index (CI), RTOG homogeneity index (HI), dose gradient index R{sub 50}-R{sub 100} (defined as the difference between equivalent sphere radius of 50% isodose volume and prescription isodose volume), and normal tissue volume (as a ratio to PTV volume) receiving 50% prescription dose (NTV{sub 50}) were calculated. Results: HI was inversely related to the beam margins around the PTV. CI had a ''V'' shaped relationship with HI, reaching a minimum when HI was approximately 1.3. Isocenter dose and mean PTV dose (as percentage of PD) increased linearly with HI. R{sub 50}-R{sub 100} and NTV{sub 50} initially declined with HI and then reached a plateau when HI was approximately 1.3. These trends also held when tumors were grouped according to their maximum diameters. The smallest tumor group

  3. Comparison of a single-dose vectored thermal pulsation procedure with a 3-month course of daily oral doxycycline for moderate-to-severe meibomian gland dysfunction.

    Science.gov (United States)

    Hagen, Kerry B; Bedi, Raman; Blackie, Caroline A; Christenson-Akagi, Kellie J

    2018-01-01

    The aim of this study was to compare the efficacy of a single bilateral 12-minute vectored thermal pulsation (VTP) procedure versus daily oral doxycycline for 3 months for moderate-to-severe meibomian gland dysfunction (MGD). This prospective, randomized, parallel-group, single-masked study included 28 subjects who received either a single-dose VTP or 3 months of doxycycline treatment. At baseline and 3 months post treatment, all subjects were evaluated for the following: dry eye symptoms with a standard dry eye questionnaire (the Standard Patient Evaluation for Eye Dryness [SPEED]), meibomian gland (MG) function by counting the number of glands yielding liquid secretion with the MG evaluator (MGE), tear breakup time (TBUT) and corneal and conjunctival staining. In the VTP group, at 3 months, there was a significant improvement in MG function (4.00±1.47 to 7.73±5.53), SPEED score (11.00±3.30 to 5.42±2.15), TBUT (6.26±2.01 to 8.44±1.81), corneal staining (0.38±0.50 to 0.12±0.33) and conjunctival staining (1.69±1.93 to 0.62±0.85). In the doxycycline group, there was a significant improvement in MG function (4.63±1.41 to 10.63±5.91), SPEED score (13.42±4.17 to 9.42±5.47) and conjunctival staining (2.38±1.88 to 1.13±1.51), but the improvement in TBUT (6.90±2.56 to 7.59±2.03) and corneal staining (0.21±0.41 to 0.13±0.34) was not statistically significant ( p =0.262 and p =0.414, respectively). At 3 months, SPEED score was significantly better in the VTP group ( p oral doxycycline at improving the dry eye symptoms secondary to MGD. A single 12-minute VTP treatment was at least as effective as a dose of doxycycline for 3 months, in improving MG function and all measured signs of MGD. Given the minimal risk profile of the single VTP procedure over long-term doxycycline use, a single VTP presents a favorable alternative to long-term antibiotic use.

  4. Development of Variational Guiding Center Algorithms for Parallel Calculations in Experimental Magnetic Equilibria

    Energy Technology Data Exchange (ETDEWEB)

    Ellison, C. Leland [PPPL; Finn, J. M. [LANL; Qin, H. [PPPL; Tang, William M. [PPPL

    2014-10-01

    Structure-preserving algorithms obtained via discrete variational principles exhibit strong promise for the calculation of guiding center test particle trajectories. The non-canonical Hamiltonian structure of the guiding center equations forms a novel and challenging context for geometric integration. To demonstrate the practical relevance of these methods, a prototypical variational midpoint algorithm is applied to an experimental magnetic equilibrium. The stability characteristics, conservation properties, and implementation requirements associated with the variational algorithms are addressed. Furthermore, computational run time is reduced for large numbers of particles by parallelizing the calculation on GPU hardware.

  5. A trial of radiation dose prescription based on dose-cell survival formula

    International Nuclear Information System (INIS)

    Allen, E.P.

    1984-01-01

    Radiation treatment has been prescribed for 379 basal cell carcinomata on the basis of a selected equivalent single dose derived from the standard multi-target dose-cell survival formula using values of m = 2 and Do = 130 rads for orthovoltage x-rays. The results suggest that the approach provides a flexible and acceptable alternative to prescription by total dose or by Nominal Standard Dose. It is submitted that Total Dose is an inadequate expression of radiobiological effects: that the NSD and related systems are valuable measures of the ability of normal tissues to recover from radiation damage: and that a parallel measure of the degree of tumour depopulation has become necessary to allow further progress in alternative fractionation schedules

  6. Application of the DMRG in two dimensions: a parallel tempering algorithm

    Science.gov (United States)

    Hu, Shijie; Zhao, Jize; Zhang, Xuefeng; Eggert, Sebastian

    The Density Matrix Renormalization Group (DMRG) is known to be a powerful algorithm for treating one-dimensional systems. When the DMRG is applied in two dimensions, however, the convergence becomes much less reliable and typically ''metastable states'' may appear, which are unfortunately quite robust even when keeping a very high number of DMRG states. To overcome this problem we have now successfully developed a parallel tempering DMRG algorithm. Similar to parallel tempering in quantum Monte Carlo, this algorithm allows the systematic switching of DMRG states between different model parameters, which is very efficient for solving convergence problems. Using this method we have figured out the phase diagram of the xxz model on the anisotropic triangular lattice which can be realized by hardcore bosons in optical lattices. SFB Transregio 49 of the Deutsche Forschungsgemeinschaft (DFG) and the Allianz fur Hochleistungsrechnen Rheinland-Pfalz (AHRP).

  7. Factors impacting short and long-term kidney graft survival: modification by single intra-operative -high-dose induction with ATG-Fresenius.

    Science.gov (United States)

    Kaden, Jürgen; May, Gottfried; Völp, Andreas; Wesslau, Claus

    2011-01-01

    A majority of recipients benefited from the intra-operative single high-dose induction (HDI) with ATG-Fresenius (ATG-F) still leaving a group of recipients who did not profit from this kind of induction. Therefore the aim of this retrospective analysis was 1st to identify the risk factors impacting short and long-term graft survival, and 2nd to assess the efficacy of this type of induction in kidney graft recipients with or without these risk factors. A total of 606 recipients receiving two different immunosuppressive treatment regimens (1st: Triple drug therapy [TDT, n=196] consisting mainly of steroids, azathioprine and cyclosporine; 2nd: TDT + 9 mg/kg ATG-F intra-operatively [HDI, n=410]) were included in this analysis and grouped according to their kidney graft survival time (short GST: ≤1 yr, n=100 and long GST: >5 yrs, n=506). The main risk factors associated with a shortened graft survival were pre-transplant sensitization, re-transplantation, rejections (in particular vascular or mixed ones) and the necessity of a long-term anti-rejection therapy. Adding ATG-F single high dose induction to TDT was more efficient in prolonging kidney graft survival than TDT alone not only in recipients without any risk factors (p<0.005) but also in recipients with at least one risk factor (p<0.021). Only in 4.6% of recipients having two or more risk factors this effect could not be demonstrated. The intra-operative single high-dose induction with ATG-F significantly improves the kidney graft survival in recipients with or without risk factors and can therefore be recommended.

  8. Psychodrama: A Creative Approach for Addressing Parallel Process in Group Supervision

    Science.gov (United States)

    Hinkle, Michelle Gimenez

    2008-01-01

    This article provides a model for using psychodrama to address issues of parallel process during group supervision. Information on how to utilize the specific concepts and techniques of psychodrama in relation to group supervision is discussed. A case vignette of the model is provided.

  9. Effects of local single and fractionated X-ray doses on rat bone marrow blood flow and red blood cell volume

    International Nuclear Information System (INIS)

    Pitkaenen, M.A.; Hopewell, J.W.

    1985-01-01

    Time and dose dependent changes in blood flow and red blood cell volume were studied in the locally irradiated bone marrow of the rat femur after single and fractionated doses of X-rays. With the single dose of 10 Gy the bone marrow blood flow although initially reduced returned to the control levels by seven months after irradiation. With doses >=15 Gy the blood flow was still significantly reduced at seven months. The total dose levels predicted by the nominal standard dose equation for treatments in three, six or nine fractions produced approximately the same degree of reduction in the bone marrow blood flow seven months after the irradiation. However, the fall in the red blood cell volume was from 23 to 37% greater in the three fractions groups compared with that in the nine fractions groups. Using the red blood cell volume as a parameter the nominal standard dose formula underestimated the severity of radiation damage in rat bone marrow at seven months for irradiation with small numbers of large dose fractions. (orig.) [de

  10. Evaluation of the sterility of single-dose medications used in a multiple-dose fashion.

    Science.gov (United States)

    Martin, Elizabeth P; Mukherjee, Jean; Sharp, Claire R; Sinnott-Stutzman, Virginia B

    2017-11-01

    Bacterial proliferation was evaluated in single-dose medications used in a multi-dose fashion and when medications were intentionally inoculated with bacteria. Of 5 experimentally punctured medications, 1 of 75 vials (50% dextrose) became contaminated. When intentionally inoculated, hydroxyethyl starch and heparinized saline supported microbial growth. Based on these findings, it is recommended that hydroxyethyl starch and heparinized saline not be used in a multi-dose fashion.

  11. Effects of single-dose atorvastatin on interleukin-6, interferon gamma, and myocardial no-reflow in a rabbit model of acute myocardial infarction and reperfusion

    International Nuclear Information System (INIS)

    Zhao, X.J.; Liu, X.L.; He, G.X.; Xu, H.P.

    2014-01-01

    The mechanisms of statins relieving the no-reflow phenomenon and the effects of single-dose statins on it are not well known. This study sought to investigate the effects of inflammation on the no-reflow phenomenon in a rabbit model of acute myocardial infarction and reperfusion (AMI/R) and to evaluate the effects of single-dose atorvastatin on inflammation and myocardial no-reflow. Twenty-four New Zealand white male rabbits (5-6 months old) were randomized to three groups of eight: a sham-operated group, an AMI/R group, and an atorvastatin-treated group (10 mg/kg). Animals in the latter two groups were subjected to 4 h of coronary occlusion followed by 2 h of reperfusion. Serum levels of interleukin (IL)-6 were measured by enzyme-linked immunosorbent assay. The expression of interferon gamma (IFN-γ) in normal and infarcted (reflow and no-reflow) myocardial tissue was determined by immunohistochemical methods. The area of no-reflow and necrosis was evaluated pathologically. Levels of serum IL-6 were significantly lower in the atorvastatin group than in the AMI/R group (P<0.01). Expression of IFN-γ in infarcted reflow and no-reflow myocardial tissue was also significantly lower in the atorvastatin group than in the AMI/R group. The mean area of no-reflow [47.01% of ligation area (LA)] was significantly smaller in the atorvastatin group than in the AMI/R group (85.67% of LA; P<0.01). The necrosis area was also significantly smaller in the atorvastatin group (85.94% of LA) than in the AMI/R group (96.56% of LA; P<0.01). In a secondary analysis, rabbits in the atorvastatin and AMI/R groups were divided into two groups based on necrosis area (90% of LA): a small group (<90% of LA) and a large group (>90% of LA). There was no significant difference in the area of no-reflow between the small (61.40% of LA) and large groups (69.87% of LA; P>0.05). Single-dose atorvastatin protected against inflammation and myocardial no-reflow and reduced infarct size during AMI/R in

  12. Effects of single-dose atorvastatin on interleukin-6, interferon gamma, and myocardial no-reflow in a rabbit model of acute myocardial infarction and reperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, X. J. [Affiliated Hospital of Binzhou Medical University, Department of Cardiology, Binzhou, China, Department of Cardiology, Affiliated Hospital of Binzhou Medical University, Binzhou (China); Liu, X. L. [Qilu Hospital, Shandong University, Department of Cardiology, Jinan, China, Department of Cardiology, Qilu Hospital, Shandong University, Jinan (China); He, G. X. [Third Military Medical University, Southwest Hospital, Department of Cardiology, Chongqing, China, Department of Cardiology, Southwest Hospital, Third Military Medical University, Chongqing (China); Xu, H. P. [Affiliated Hospital of Binzhou Medical University, Department of Cardiology, Binzhou, China, Department of Cardiology, Affiliated Hospital of Binzhou Medical University, Binzhou (China)

    2014-03-03

    The mechanisms of statins relieving the no-reflow phenomenon and the effects of single-dose statins on it are not well known. This study sought to investigate the effects of inflammation on the no-reflow phenomenon in a rabbit model of acute myocardial infarction and reperfusion (AMI/R) and to evaluate the effects of single-dose atorvastatin on inflammation and myocardial no-reflow. Twenty-four New Zealand white male rabbits (5-6 months old) were randomized to three groups of eight: a sham-operated group, an AMI/R group, and an atorvastatin-treated group (10 mg/kg). Animals in the latter two groups were subjected to 4 h of coronary occlusion followed by 2 h of reperfusion. Serum levels of interleukin (IL)-6 were measured by enzyme-linked immunosorbent assay. The expression of interferon gamma (IFN-γ) in normal and infarcted (reflow and no-reflow) myocardial tissue was determined by immunohistochemical methods. The area of no-reflow and necrosis was evaluated pathologically. Levels of serum IL-6 were significantly lower in the atorvastatin group than in the AMI/R group (P<0.01). Expression of IFN-γ in infarcted reflow and no-reflow myocardial tissue was also significantly lower in the atorvastatin group than in the AMI/R group. The mean area of no-reflow [47.01% of ligation area (LA)] was significantly smaller in the atorvastatin group than in the AMI/R group (85.67% of LA; P<0.01). The necrosis area was also significantly smaller in the atorvastatin group (85.94% of LA) than in the AMI/R group (96.56% of LA; P<0.01). In a secondary analysis, rabbits in the atorvastatin and AMI/R groups were divided into two groups based on necrosis area (90% of LA): a small group (<90% of LA) and a large group (>90% of LA). There was no significant difference in the area of no-reflow between the small (61.40% of LA) and large groups (69.87% of LA; P>0.05). Single-dose atorvastatin protected against inflammation and myocardial no-reflow and reduced infarct size during AMI/R in

  13. Point Organ Radiation Dose in Abdominal CT: Effect of Patient Off-Centering in an Experimental Human Cadaver Study.

    Science.gov (United States)

    Ali Khawaja, Ranish Deedar; Singh, Sarabjeet; Padole, Atul; Otrakji, Alexi; Lira, Diego; Zhang, Da; Liu, Bob; Primak, Andrew; Xu, George; Kalra, Mannudeep K

    2017-08-01

    To determine the effect of patient off-centering on point organ radiation dose measurements in a human cadaver scanned with routine abdominal CT protocol. A human cadaver (88 years, body-mass-index 20 kg/m2) was scanned with routine abdominal CT protocol on 128-slice dual source MDCT (Definition Flash, Siemens). A total of 18 scans were performed using two scan protocols (a) 120 kV-200 mAs fixed-mA (CTDIvol 14 mGy) (b) 120 kV-125 ref mAs (7 mGy) with automatic exposure control (AEC, CareDose 4D) at three different positions (a) gantry isocenter, (b) upward off-centering and (c) downward off-centering. Scanning was repeated three times at each position. Six thimble (in liver, stomach, kidney, pancreas, colon and urinary bladder) and four MOSFET dosimeters (on cornea, thyroid, testicle and breast) were placed for calculation of measured point organ doses. Organ dose estimations were retrieved from dose-tracking software (eXposure, Radimetrics). Statistical analysis was performed using analysis of variance. There was a significant difference between the trends of point organ doses with AEC and fixed-mA at all three positions (p 92% for both protocols; p < 0.0001). For both protocols, the highest mean difference in point doses was found for stomach and lowest for colon. Measured absorbed point doses in abdominal CT vary with patient-centering in the gantry isocenter. Due to lack of consideration of patient positioning in the dose estimation on automatic software-over estimation of the doses up to 92% was reported. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. ‌‌The effect of nicotine administration on physical and psychological signs of withdrawal syndrome induced by single or frequent doses of morphine in rats

    Directory of Open Access Journals (Sweden)

    Ali Shamsizadeh

    2012-07-01

    Full Text Available Introduction: Morphine addiction and morphine withdrawal syndrome are the two main problems of today’s human society. The present study has investigated the effects of nicotine on the strength of physical and psychological dependency in single and repeated doses morphine administrated rats. Methods: Male Wistar rats were subjected to morphine consumption with single or frequent dose protocols. In the single dose protocol, rats received only one dose of morphine and 24hrs later they also received one dose of nicotine 30 min prior to injection of naloxone. In the repeated dose protocol, rats received incremental doses of morphine for 7 days and 24hr after the last dose (the 8th day were given naloxone. However, the nicotine regimen of this group was injected 15 min before the morphine injection, for 4 days, from the 4th to the 7th day. Five minutes after naloxone injection, each rat′s behavior was captured for 30 min, and then physical and psychological signs of withdrawal syndrome were recorded. Data were analyzed by ANOVA followed by Tukey tests and p<0.05 was considered as significant difference. Results: Results showed that the injection of frequent and single doses of morphine lead to morphine dependency. In single dose protocol, nicotine consumption attenuated the signs of withdrawal syndrome, especially weight of excrement and total withdrawal score. In frequent dose protocol, in addition to these effects, nicotine induced weight loss and place aversion. Discussion: The inhibitory effects of nicotine on signs of withdrawal syndrome may involve a dopaminergic portion of the central nervous system and is mediated by central nicotinic receptors. There is also a cross-dependence between nicotine and morphine.

  15. A single-dose of oral nattokinase potentiates thrombolysis and anti-coagulation profiles.

    Science.gov (United States)

    Kurosawa, Yuko; Nirengi, Shinsuke; Homma, Toshiyuki; Esaki, Kazuki; Ohta, Mitsuhiro; Clark, Joseph F; Hamaoka, Takafumi

    2015-06-25

    Our aim was to determine the quantitative effects of a single-dose of Nattokinase (NK) administration on coagulation/fibrinolysis parameters comprehensively in healthy male subjects. A double-blind, placebo-controlled cross-over NK intervention study was carried out in 12 healthy young males. Following the baseline blood draw, each subject was randomized to receive either a single-dose of 2,000 FU NK (NSK-SD, Japan Bio Science Laboratory Co., Ltd) or placebo with subsequent cross-over of the groups. Subjects donated blood samples at 2, 4, 6 and 8 hours following administration for analysis of coagulation/fibrinolysis parameters. As a result, D-dimer concentrations at 6, and 8 hours, and blood fibrin/fibrinogen degradation products at 4 hours after NK administration elevated significantly (p < 0.05, respectively). Factor VIII activity declined at 4 and 6 hours (p < 0.05, respectively), blood antithrombin concentration was higher at 2 and 4 hours (p < 0.05, respectively), and the activated partial thromboplastin time prolonged significantly at 2 and 4 hours following NK administration (p < 0.05 and p < 0.01, respectively). All the changes, however, were within the normal range. In conclusion, thus, a single-dose of NK administration appears enhancing fibrinolysis and anti-coagulation via several different pathways simultaneously.

  16. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Moussazadeh, Nelson; Lis, Eric; Katsoulakis, Evangelia; Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily; Bilsky, Mark H.; Yamada, Yoshiya; Laufer, Ilya

    2015-01-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  17. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Moussazadeh, Nelson [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Lis, Eric [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Katsoulakis, Evangelia [Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, New York (United States); Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Bilsky, Mark H. [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Yamada, Yoshiya [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Laufer, Ilya, E-mail: lauferi@mskcc.org [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States)

    2015-10-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  18. Long-term ingestion dose monitoring in a population group with increased 137Cs intake

    International Nuclear Information System (INIS)

    Bartuskova, M.; Lusnak, J.; Malatova, I.; Pfeiferova, V.; Pospisilova, H.

    2008-01-01

    137 Cs amounts and ingestion doses in Czech population have been monitored by whole-body counting since the Chernobyl accident. Indirect estimation of the retention through measurement of 137 Cs excreted with urine in 24 hours has also been performed since 1987. The 137 Cs content in human body can be calculated from the urine data provided that the intake of 137 Cs during the period of interest is constant. In a semi-natural environment, the 137 Cs content in mushrooms, wild berries and game decreases due to its natural decay solely. The 137 Cs content in people who mostly consume venison and have been living in an area with elevated contamination has been monitored, mostly through measurement of 137 Cs in urine. In parallel, measurements with a mobile whole-body counter have also been performed. Currently, annual doses from the ingestion of 137 Cs in the inhabitants are very low (0.001 to 0.002 mSv.year -1 ). In a group of hunters in the Jeseniky Mountains (Northern Moravia) the doses were estimated to 0.10 mSv.year -1 . (orig.)

  19. Mycophenolate mofetil in pediatric renal transplantation: A single center experience.

    LENUS (Irish Health Repository)

    Raheem, Omer A

    2011-05-01

    Raheem OA, Kamel MH, Daly PJ, Mohan P, Little DM, Awan A, Hickey DP. Mycophenolate mofetil in pediatric renal transplantation: A single center experience. Pediatr Transplantation 2011: 15:240-244. © 2009 John Wiley & Sons A\\/S. Abstract:  We assessed our long-term experience with regards to the safety and efficacy of MMF in our pediatric renal transplant population and compared it retrospectively to our previous non-MMF immunosuppressive regimen. Forty-seven pediatric renal transplants received MMF as part of their immunosuppressive protocol in the period from January 1997 till October 2006 (MMF group). A previously reported non-MMF group of 59 pediatric renal transplants was included for comparative analysis (non-MMF group). The MMF group comprised 29 boys and 18 girls, whereas the non-MMF group comprised 34 boys and 25 girls. Mean age was 11.7 and 12 yr in the MMF and non-MMF groups, respectively. The incidence of acute rejection episodes was 11 (23.4%) and 14 (24%) in the MMF and non-MMF group, respectively. Two (3.3%) grafts were lost in the non-MMF group compared with one (2.1%) in the MMF group. Twenty-one (44.68%) patients in the MMF group developed post-transplant infections compared with 12 (20.33%) in the non-MMF group (p < 0.0001). In conclusion, the use of MMF in pediatric renal transplantation was not associated with a lower rejection rate or immunological graft loss. It did, however, result in a significantly higher rate of viral infections.

  20. Single-dose-response curves of murine gastrointestinal crypt stem cells

    International Nuclear Information System (INIS)

    Masuda, K.; Withers, H.R.; Mason, K.A.; Chen, K.Y.

    1977-01-01

    Dose-response curves for the reproductive capacity of crypt stem cells of murine colonic, jejunal, and gastric mucosae exposed in situ to multifractionated gamma ray exposures were analyzed and single-dose-survival curves of these cells were constructed. The following conclusions were drawn: (1) The single-dose-response curves bend downward over a dose range of approximately 200 to 1500 rad; (2) cell death seems to be due to nonrepairable damage at doses less than 250 rad for colon, and 220 rad for jejunum; (3) there are 21, 110, and 140 stem cells per crypt of gastric, colonic, and jejunal mucosa, respectively; and (4) jejunal stem cells are the most radiosensitive and gastric mucosal stem cells are the most resistant

  1. Effects of a single high dose of 55Fe in mice

    International Nuclear Information System (INIS)

    Laissue, J.A.; Burlington, H.; Cronkite, E.P.; Heldman, B.; Reincke, U.

    1979-01-01

    High doses of 55 Fe induced cytocide in maturing erythroid cells, due to the short-range deposition of decay energy. Organ damage at the time of death was evaluated in a group of 45 female mice of the C 57 BL/6 J strain given a single i.v. injection of 2,800 μCi, 1,400 μCi or 700 μCi of 55 FeCl 3 when 10 to 14 weeks old. A corresponding amount of cold iron was given to control animals by the same route. Radioiron-treated mice died spontaneously, or were killed when moribund. Mice given 2,800 μCi died after a median survival time of 27 days with severe depletion of hemopoietic cells in bone marrow and spleen, marked atrophy of lymphoid tissues and mild liver damage. After 1,400 μCi or 700 μCi, the median survival time was 117 and 439, respectively. In contrast, median survival was 847 days in control animals allowed to survive. In the two lower 55 Fe-dose groups, there was a dose-dependent pancytopenia. Atrophy of lymphoid tissues was moderate, and signs of liver damage slight. The degree of organ hemosiderosis in experimental and control animals was slight to moderate. Organ damage associated with deposition of cold iron was not apparent in tissue sections. Morphological signs of damage to non-hemopoietic organs such as the liver were not conspicuous. Direct radiation damage, primarily to the erythroid series, and competition for stem cells between the heavily depleted erythroid and the other hemopoietic cell lines must be considered among the possible factors leading to pancytopenia. Out of 14 55 Fe-treated mice who survived longer than 300 days developed tumors of hemopoietic and lymphoid tissues, or osteosarcomas. (orig./MG) [de

  2. Single-dose radiotherapy for painful bone metastases

    International Nuclear Information System (INIS)

    Kal, H.B.

    1999-01-01

    Background: External beam radiotherapy is frequently applied for palliative treatment of painful bone lesions with a variety of fractionation schemes. There is a continuous interest to administer only 1 or a few dose fractions for inducing pain relief. Methods: A review of the literature was made with the aim to determine whether a treatment can be deduced that is simple and effective. The linear-quadratic (L-Q) concept was applied to compare reported therapy schemes which each other for the iso-effect pain relief. Results: Single-dose and fractionated radiotherapy resulted in partial or complete pain relief in about 80% of the patients. Complete responses have been observed in about 43% of the patients. For patients responding to treatment, the duration of pain relief is at least 3 to 4 months with reported duration of up to 1 year or even longer. Conclusion: Based on this review of literature data concerning randomized trials a treatment with a single dose of 8 Gy is effective for inducing pain relief. (orig.) [de

  3. Single versus double dose praziquantel comparison on efficacy and Schistosoma mansoni re-infection in preschool-age children in Uganda

    DEFF Research Database (Denmark)

    Nalugwa, Allen; Nuwaha, Fred; Tukahebwa, Edridah Muheki

    2015-01-01

    BACKGROUND: Schistosoma mansoni infection is proven to be a major health problem of preschool-age children in sub-Saharan Africa, yet this age category is not part of the schistosomiasis control program. The objective of this study was to compare the impact of single and double dose praziquantel...... (PZQ) treatment on cure rates (CRs), egg reduction rates (ERRs) and re-infection rates 8 months later, in children aged 1-5 years living along Lake Victoria, Uganda. METHODOLOGY/PRINCIPAL FINDINGS: Infected children (n= 1017) were randomized to receive either a single or double dose of PZQ. Initially...... all children were treated with a single standard oral dose 40 mg/kg body weight of PZQ. Two weeks later a second dose was administered to children in the double dose treatment arm. Side effects were monitored at 30 minutes to 24 hours after each treatment. Efficacy in terms of CRs and ERRs for the two...

  4. Effect of propranolol in head tremor: quantitative study following single-dose and sustained drug administration.

    Science.gov (United States)

    Calzetti, S; Sasso, E; Negrotti, A; Baratti, M; Fava, R

    1992-12-01

    The effect of the beta-adrenoceptor antagonist propranolol has been investigated in nine patients suffering from isolated (six patients) or prominent (three patients) essential tremor of the head. In a double-blind, placebo-controlled study the tremorolytic efficacy of propranolol has been assessed by a quantitative accelerometric method after a single oral dose (120 mg) and following 2 weeks of sustained treatment with two different dosage regimens of the drug (120 and 240 mg daily). As compared with placebo, a significant reduction in tremor magnitude was found following a single oral dose but not on sustained administration of the beta-blocker at either dosage. The results suggest that the efficacy of sustained propranolol on isolated or prominent essential head tremor is less predictable and satisfactory than expected on the basis of the single-dose response, as compared with hand tremor.

  5. Parallel programming of saccades during natural scene viewing: evidence from eye movement positions.

    Science.gov (United States)

    Wu, Esther X W; Gilani, Syed Omer; van Boxtel, Jeroen J A; Amihai, Ido; Chua, Fook Kee; Yen, Shih-Cheng

    2013-10-24

    Previous studies have shown that saccade plans during natural scene viewing can be programmed in parallel. This evidence comes mainly from temporal indicators, i.e., fixation durations and latencies. In the current study, we asked whether eye movement positions recorded during scene viewing also reflect parallel programming of saccades. As participants viewed scenes in preparation for a memory task, their inspection of the scene was suddenly disrupted by a transition to another scene. We examined whether saccades after the transition were invariably directed immediately toward the center or were contingent on saccade onset times relative to the transition. The results, which showed a dissociation in eye movement behavior between two groups of saccades after the scene transition, supported the parallel programming account. Saccades with relatively long onset times (>100 ms) after the transition were directed immediately toward the center of the scene, probably to restart scene exploration. Saccades with short onset times (programming of saccades during scene viewing. Additionally, results from the analyses of intersaccadic intervals were also consistent with the parallel programming hypothesis.

  6. Single fixed-dose oral dexketoprofen plus tramadol for acute postoperative pain in adults.

    Science.gov (United States)

    Derry, Sheena; Cooper, Tess E; Phillips, Tudor

    2016-09-22

    Combining two different analgesics in fixed doses in a single tablet can provide better pain relief than either drug alone in acute pain. This appears to be broadly true across a range of different drug combinations, in postoperative pain and migraine headache. A new combination of dexketoprofen (a nonsteroidal anti-inflammatory drug) plus tramadol (an opioid) has been tested in acute postoperative pain conditions. It is not yet licensed for use. This review is one of a series on oral analgesics for acute postoperative pain. Individual reviews have been brought together in two overviews to provide information about the relative efficacy and harm of the different interventions. To assess the analgesic efficacy and adverse effects of a single fixed-dose of oral dexketoprofen plus tramadol, compared with placebo, for moderate to severe postoperative pain in adults, using methods that permit comparison with other analgesics evaluated in standardised trials using almost identical methods and outcomes. A secondary objective was to compare the combination with the individual analgesics alone. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) via CRSO, MEDLINE via Ovid, and Embase via Ovid from inception to 31 May 2016. We also searched the reference lists of retrieved studies and reviews, and two online clinical trial registries. Randomised, double-blind trials of oral dexketoprofen plus tramadol administered as a single oral dose, for the relief of acute postoperative pain in adults, and compared to placebo. Two review authors independently considered trials for inclusion in the review, examined issues of study quality and potential bias, and extracted data. For dichotomous outcomes, we calculated risk ratio (RR) and number needed to treat for an additional beneficial outcome (NNT) for dexketoprofen plus tramadol, compared with placebo with 95% confidence intervals (CI). We collected information on the number of participants with at least 50% of

  7. Monte Carlo uncertainty analysis of dose estimates in radiochromic film dosimetry with single-channel and multichannel algorithms.

    Science.gov (United States)

    Vera-Sánchez, Juan Antonio; Ruiz-Morales, Carmen; González-López, Antonio

    2018-03-01

    To provide a multi-stage model to calculate uncertainty in radiochromic film dosimetry with Monte-Carlo techniques. This new approach is applied to single-channel and multichannel algorithms. Two lots of Gafchromic EBT3 are exposed in two different Varian linacs. They are read with an EPSON V800 flatbed scanner. The Monte-Carlo techniques in uncertainty analysis provide a numerical representation of the probability density functions of the output magnitudes. From this numerical representation, traditional parameters of uncertainty analysis as the standard deviations and bias are calculated. Moreover, these numerical representations are used to investigate the shape of the probability density functions of the output magnitudes. Also, another calibration film is read in four EPSON scanners (two V800 and two 10000XL) and the uncertainty analysis is carried out with the four images. The dose estimates of single-channel and multichannel algorithms show a Gaussian behavior and low bias. The multichannel algorithms lead to less uncertainty in the final dose estimates when the EPSON V800 is employed as reading device. In the case of the EPSON 10000XL, the single-channel algorithms provide less uncertainty in the dose estimates for doses higher than four Gy. A multi-stage model has been presented. With the aid of this model and the use of the Monte-Carlo techniques, the uncertainty of dose estimates for single-channel and multichannel algorithms are estimated. The application of the model together with Monte-Carlo techniques leads to a complete characterization of the uncertainties in radiochromic film dosimetry. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Single vs. double dose of copper oxide wire particles (COWP) for treatment of anthelmintic resistant Haemonchus contortus in weanling lambs.

    Science.gov (United States)

    Schweizer, Nikki M; Foster, Derek M; Knox, William B; Sylvester, Hannah J; Anderson, Kevin L

    2016-10-15

    Haemonchus contortus parasitism is a major disease of sheep, with these parasites frequently demonstrating multi-drug class anthelmintic resistance. Copper oxide wire particles (COWP) have shown potential as adjuncts or alternatives to anthelmintics in resistant flocks. The purpose of this study was to compare the efficacy of two different COWP treatment regimens or placebo in the control of H. contortus in weaned lambs within a flock historically shown to have multi-drug resistant H. contortus using the DrenchRite ® assay. Data from 43 lambs within 3 treatment groups in a double blind study were included in the experiment. Treatments were administered as a total of 2 boluses, each given on separate occasions (day 0 and day 42), so that each lamb received either 2 placebos, a single dose of 2g COWP followed by placebo, or two doses of 1g COWP. Strongyle-type fecal egg counts (FEC) were performed at initial treatment (day 0), on day 10, at second treatment (day 42), on day 52, and at study end (day 84). At the start of the trial, mean±standard deviation FEC were 1634.4±825.2, 2241.7±1496.8, and 2013.3±1194.2epg for the 2g, 1g×2, and control groups, respectively. At the end of the trial, FEC were 757.1±825.3, 483.4±557.2, and 1660.0±1345.3epg for the 2g, 1g×2, and control groups, respectively. Lambs given a 2g single dose of COWP or a 1g dose of COWP twice had reductions in strongyle-type FEC (p≤0.01) from trial start to trial end, whereas lambs given placebo did not. Average daily gains did not differ significantly among groups. Although copper is potentially toxic to sheep, no signs of toxicity were observed during this trial, which was consistent with similar studies at this treatment dose. The study indicated that administering COWP to lambs at weaning reduced FEC. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Comparative Analysis of Canal Centering Ability of Different Single File Systems Using Cone Beam Computed Tomography- An In-Vitro Study.

    Science.gov (United States)

    Agarwal, Rolly S; Agarwal, Jatin; Jain, Pradeep; Chandra, Anil

    2015-05-01

    The ability of an endodontic instrument to remain centered in the root canal system is one of the most important characteristic influencing the clinical performance of a particular file system. Thus, it is important to assess the canal centering ability of newly introduced single file systems before they can be considered a viable replacement of full-sequence rotary file systems. The aim of the study was to compare the canal transportation, centering ability, and time taken for preparation of curved root canals after instrumentation with single file systems One Shape and Wave One, using cone-beam computed tomography (CBCT). Sixty mesiobuccal canals of mandibular molars with an angle of curvature ranging from 20(o) to 35(o) were divided into three groups of 20 samples each: ProTaper PT (group I) - full-sequence rotary control group, OneShape OS (group II)- single file continuous rotation, WaveOne WO - single file reciprocal motion (group III). Pre instrumentation and post instrumentation three-dimensional CBCT images were obtained from root cross-sections at 3mm, 6mm and 9mm from the apex. Scanned images were then accessed to determine canal transportation and centering ability. The data collected were evaluated using one-way analysis of variance (ANOVA) with Tukey's honestly significant difference test. It was observed that there were no differences in the magnitude of transportation between the rotary instruments (p >0.05) at both 3mm as well as 6mm from the apex. At 9 mm from the apex, Group I PT showed significantly higher mean canal transportation and lower centering ability (0.19±0.08 and 0.39±0.16), as compared to Group II OS (0.12±0.07 and 0.54±0.24) and Group III WO (0.13±0.06 and 0.55±0.18) while the differences between OS and WO were not statistically significant. It was concluded that there was minor difference between the tested groups. Single file systems demonstrated average canal transportation and centering ability comparable to full sequence

  10. Comparative Analysis of Canal Centering Ability of Different Single File Systems Using Cone Beam Computed Tomography- An In-Vitro Study

    Science.gov (United States)

    Agarwal, Jatin; Jain, Pradeep; Chandra, Anil

    2015-01-01

    Background The ability of an endodontic instrument to remain centered in the root canal system is one of the most important characteristic influencing the clinical performance of a particular file system. Thus, it is important to assess the canal centering ability of newly introduced single file systems before they can be considered a viable replacement of full-sequence rotary file systems. Aim The aim of the study was to compare the canal transportation, centering ability, and time taken for preparation of curved root canals after instrumentation with single file systems One Shape and Wave One, using cone-beam computed tomography (CBCT). Materials and Methods Sixty mesiobuccal canals of mandibular molars with an angle of curvature ranging from 20o to 35o were divided into three groups of 20 samples each: ProTaper PT (group I) – full-sequence rotary control group, OneShape OS (group II)- single file continuous rotation, WaveOne WO – single file reciprocal motion (group III). Pre instrumentation and post instrumentation three-dimensional CBCT images were obtained from root cross-sections at 3mm, 6mm and 9mm from the apex. Scanned images were then accessed to determine canal transportation and centering ability. The data collected were evaluated using one-way analysis of variance (ANOVA) with Tukey’s honestly significant difference test. Results It was observed that there were no differences in the magnitude of transportation between the rotary instruments (p >0.05) at both 3mm as well as 6mm from the apex. At 9 mm from the apex, Group I PT showed significantly higher mean canal transportation and lower centering ability (0.19±0.08 and 0.39±0.16), as compared to Group II OS (0.12±0.07 and 0.54±0.24) and Group III WO (0.13±0.06 and 0.55±0.18) while the differences between OS and WO were not statistically significant Conclusion It was concluded that there was minor difference between the tested groups. Single file systems demonstrated average canal

  11. Effects of low-dose rate irradiation on two types of type II diabetes model mice

    International Nuclear Information System (INIS)

    Nomura, Takaji; Sakai, Kazuo

    2004-01-01

    The effects of low-dose rate gamma-irradiation were investigated in two mouse strains - C57BL/KsJ-db/db (db mouse) and AKITA (AKITA mouse)-for type II diabetes mellitus. Both strains develop the developed type II diabetes by about 8 weeks of age due to dysfunction of the insulin/insulin receptor. The db Mouse' shows obese and exhibits hyperinsulinism, and the onset of Type II diabetes like resembles that for Westerners. On the other hand, the AKITA mouse has exhibits disordered insulin secretion, and the diabetes such as resembles that of Asians. Ten-week old female mice, in groups of 8 or 12, were irradiated at 0.65 mGy/hr in the low-dose rate irradiation facility in the Low Dose Radiation Research Center. The level of urine glucose was measured with test slips. The urine glucose levels of all of the mice were highly elevated the beginning of the irradiation. In the irradiated group of db mice, three mice showed decrease in glucose level compare to the level of non-irradiated diabetes mice after 35, 52 or 80 weeks of irradiation. All had maintained a normal level thereafter. No such improvement in diabetes was ever observed in the 12 mice of in the non-irradiated control group. The AKITA mice, however, did not decrease the glucose level regardless of the irradiation. Both the db mice and AKITA mice had their lives prolonged their life by the irradiation. The survival rate of db mice at the age of 90 weeks was 75% in the irradiated group, but 50% in the non-irradiated group. The average life span was 104 weeks in the irradiated group and 87 weeks in the control group. Furthermore, a marked difference was furthermore observed in the appearance of the coat hair, skin, and tail; appearances were well preserved in the irradiated group. The average life span in the irradiated AKITA mice was also longer than that for the non-irradiated mice, 51 weeks and 41 weeks in the irradiated and non-irradiated group respectively. These results suggest that the low-dose irradiation

  12. Vectorized and multitasked solution of the few-group neutron diffusion equations

    International Nuclear Information System (INIS)

    Zee, S.K.; Turinsky, P.J.; Shayer, Z.

    1989-01-01

    A numerical algorithm with parallelism was used to solve the two-group, multidimensional neutron diffusion equations on computers characterized by shared memory, vector pipeline, and multi-CPU architecture features. Specifically, solutions were obtained on the Cray X/MP-48, the IBM-3090 with vector facilities, and the FPS-164. The material-centered mesh finite difference method approximation and outer-inner iteration method were employed. Parallelism was introduced in the inner iterations using the cyclic line successive overrelaxation iterative method and solving in parallel across lines. The outer iterations were completed using the Chebyshev semi-iterative method that allows parallelism to be introduced in both space and energy groups. For the three-dimensional model, power, soluble boron, and transient fission product feedbacks were included. Concentrating on the pressurized water reactor (PWR), the thermal-hydraulic calculation of moderator density assumed single-phase flow and a closed flow channel, allowing parallelism to be introduced in the solution across the radial plane. Using a pinwise detail, quarter-core model of a typical PWR in cycle 1, for the two-dimensional model without feedback the measured million floating point operations per second (MFLOPS)/vector speedups were 83/11.7. 18/2.2, and 2.4/5.6 on the Cray, IBM, and FPS without multitasking, respectively. Lower performance was observed with a coarser mesh, i.e., shorter vector length, due to vector pipeline start-up. For an 18 x 18 x 30 (x-y-z) three-dimensional model with feedback of the same core, MFLOPS/vector speedups of --61/6.7 and an execution time of 0.8 CPU seconds on the Cray without multitasking were measured. Finally, using two CPUs and the vector pipelines of the Cray, a multitasking efficiency of 81% was noted for the three-dimensional model

  13. Effect of adding celecoxib to a single dose of gabapentin on postoperative pain relief

    Directory of Open Access Journals (Sweden)

    Mansour Choubsaz

    2015-01-01

    Full Text Available Background: In recent years, several studies with conflicting results have been done on the role of gabapentin and non-steroidal anti-inflammatory drugs in pre-emptive analgesia to control postoperative pain. The purpose of this study was to evaluate the effect of adding low doses of celecoxib to gabapentin on increasing the analgesic effect and patients’ satisfaction. Methods: In this double-blind randomized clinical trial, 130 patients with ASA I, II class were divided in two groups as they were the candidates for elective inguinal hernia surgery with spinal anesthesia. Before the surgery, the control group (G received 300 mg oral dose of gabapentin and the study group (GC received 100 mg celecoxib in addition to the above dose. Severity of patients’ pain was measured using the visual analogue scale (VAS. By the same token, the amount of painkillers usedwas measured and statistically analyzed. Results: The results suggested a statistically significant difference between the two groups in terms of pain level 4, 6 and 24 hours after surgery (P<0.05. Adding low-dose of celeoxib to gabapentin before the surgery and the combination of these two drugs caused further reduction of pain 4, 6 and 24 h after the surgery in comparison to the administration of gabapentin alone. Conclusion: Adding 100 mg celecoxib to 300 mg gabapentin resulted in a reduction of pain level 24 h after elective surgery of inguinal hernia in patients of control group (P<0.05. However, in terms of using painkillers (analgesics, there was no statistically significant difference between the two groups.

  14. Image quality and radiation dose of single heartbeat 640-slice coronary CT angiography: A comparison between patients with chronic Atrial Fibrillation and subjects in normal sinus rhythm by propensity analysis

    Energy Technology Data Exchange (ETDEWEB)

    Di Cesare, Ernesto, E-mail: ernesto.dicesare@cc.univaq.it [Department of Biotechnological and Applied Clinical Sciences, Division of Radiotherapy, Laboratory of Radiobiology, University of L’Aquila (Italy); Gennarelli, Antonio; Di Sibio, Alessandra; Felli, Valentina; Splendiani, Alessandra [Department of Biotechnological and Applied Clinical Sciences, Division of Radiology, Laboratory of Radiobiology, University of L’Aquila (Italy); Gravina, Giovanni Luca [Department of Biotechnological and Applied Clinical Sciences, Division of Radiotherapy, Laboratory of Radiobiology, University of L’Aquila (Italy); Masciocchi, Carlo [Department of Biotechnological and Applied Clinical Sciences, Division of Radiology, Laboratory of Radiobiology, University of L’Aquila (Italy)

    2015-04-15

    Highlights: •Atrial Fibrillation (AF) may affect CCTA image quality. •We compare the results of single heartbeat CCTA in subjects with chronic AF and in sinus rhythm. •Single heartbeat CCTA may be feasible also in subjects with cAF and HR <72 bpm. •In cAF patients with heart rate higher than 72 bpm, CCTA has more movement-associated artefacts. •Mean effective dose of single heartbeat CCTA in cAF group was higher than in sinus rhythm one. -- Abstract: Objectives: To evaluate image quality and radiation dose of single heartbeat 640-slice coronary CT angiography (CCTA) in patients with chronic Atrial Fibrillation (cAF) in comparison with subjects in normal sinus rhythm. Methods: A cohort of 71 patients with cAF was matched with 71 subjects in normal sinus rhythm (NSR) and HR ≤ 65 bpm using a matched by propensity analysis. All subjects underwent a single heartbeat CCTA with prospective gating. In subjects with cAF, we manually established the acquisition of data only from a single heartbeat. Mean effective dose and image quality, with both objective and subjective measures, were assessed. Results: 96.4% of all segments in the cAF group had diagnostic image quality. The rate of subjects with at least one non-diagnostic segment was 14% and 2.8% (p = 0.031) in the cAF and NRS groups, respectively. In the cAF group, the percentage of patients with at least one non-diagnostic segment for acquisition HR ≤ 72 was 1.8% (1/55), and it did not significantly differ from the NSR group (2.8%; 2/71) (p = 1.0). Objective quality parameters did not show a statistically significant difference between the two groups. The mean effective dose was 4.24 ± 1.24 mSv in the cAF group and 2.67 ± 0.5 mSv in the sinus rhythm group (p < 0.0001) with an increase by 59% in the cAF group with respect to the SNR group. Conclusions: A single heartbeat acquisition protocol with a 640-slice prospectively ECG-triggered CT angiography may be feasible in patients with cAF and HR below 72

  15. Image quality and radiation dose of single heartbeat 640-slice coronary CT angiography: A comparison between patients with chronic Atrial Fibrillation and subjects in normal sinus rhythm by propensity analysis

    International Nuclear Information System (INIS)

    Di Cesare, Ernesto; Gennarelli, Antonio; Di Sibio, Alessandra; Felli, Valentina; Splendiani, Alessandra; Gravina, Giovanni Luca; Masciocchi, Carlo

    2015-01-01

    Highlights: •Atrial Fibrillation (AF) may affect CCTA image quality. •We compare the results of single heartbeat CCTA in subjects with chronic AF and in sinus rhythm. •Single heartbeat CCTA may be feasible also in subjects with cAF and HR <72 bpm. •In cAF patients with heart rate higher than 72 bpm, CCTA has more movement-associated artefacts. •Mean effective dose of single heartbeat CCTA in cAF group was higher than in sinus rhythm one. -- Abstract: Objectives: To evaluate image quality and radiation dose of single heartbeat 640-slice coronary CT angiography (CCTA) in patients with chronic Atrial Fibrillation (cAF) in comparison with subjects in normal sinus rhythm. Methods: A cohort of 71 patients with cAF was matched with 71 subjects in normal sinus rhythm (NSR) and HR ≤ 65 bpm using a matched by propensity analysis. All subjects underwent a single heartbeat CCTA with prospective gating. In subjects with cAF, we manually established the acquisition of data only from a single heartbeat. Mean effective dose and image quality, with both objective and subjective measures, were assessed. Results: 96.4% of all segments in the cAF group had diagnostic image quality. The rate of subjects with at least one non-diagnostic segment was 14% and 2.8% (p = 0.031) in the cAF and NRS groups, respectively. In the cAF group, the percentage of patients with at least one non-diagnostic segment for acquisition HR ≤ 72 was 1.8% (1/55), and it did not significantly differ from the NSR group (2.8%; 2/71) (p = 1.0). Objective quality parameters did not show a statistically significant difference between the two groups. The mean effective dose was 4.24 ± 1.24 mSv in the cAF group and 2.67 ± 0.5 mSv in the sinus rhythm group (p < 0.0001) with an increase by 59% in the cAF group with respect to the SNR group. Conclusions: A single heartbeat acquisition protocol with a 640-slice prospectively ECG-triggered CT angiography may be feasible in patients with cAF and HR below 72

  16. The effect of a single dose of morphine on muscle fatigue indices in male rats

    Directory of Open Access Journals (Sweden)

    Sedigheh Amiresmaili

    2016-09-01

    Full Text Available Background and Aim: Endogenous opioids and addictive opiate drugs change many body functions. . Previous studies have referred to the effects of morphine on smooth and pulmonary muscles ., but the  effects of opioids on skeletal muscles is not known well. Thus, the current study aimed at assessing the effect of a single dose of morphine on muscle fatigue in male rats. Materials and Methods: In this experimental study, 40 male Wistar rats weighing 220-270 g were randomly divided into four equal groups: control (the mice were kept in their cages and received food and water, morphine receiving group, fatigue group (the mice in this group were kept running on  a treadmill . for120 minutes at a rate of 20 meters per minute, and morphine plus fatigue group. At the end of the experiments, blood samples were obtained from the corner of their eyes and were sent to the laboratory for measurement of muscle fatigue indexes including lactate dehydrogenase (LDH and creatine phosphokinase (CPK. Results: Administration of morphine to the fatigue group decreased running time compared with the control group (P=0.009. Furthermore, administration of morphine to the fatigue group significantly increased serum levels of LDH (P=0.009 and CPK (P=0.008. Conclusion: The present study showed that administration of a single dose of morphine in rats increases muscle fatigue biomarkers (LDH, CPK.

  17. A randomized clinical trial with two doses of an enteral diabetes-specific suplements in elderly patients with diabetes mellitus type 2.

    Science.gov (United States)

    de Luis, D A; Izaola, O; de la Fuente, B; Terroba, M C; Cuellar, L; Cabezas, G

    2013-06-01

    The aim of our study was to investigate whether two different daily doses of a high monounsaturated fatty acid (MUFA) specific diabetes enteral formula could improve nutritional variables as well as metabolic parameters. We conducted a randomized, open-label, multicenter, parallel group study. 27 patients with diabetes mellitus type 2 with recent weight loss were randomized to one of two study groups: group 1 (two cans per day) and group 2 (three cans per day) for a ten week period. A significative decrease of HbA1c was detected in both groups. The decrease 0.98% (confidence interval 95% 0.19-1.88) was higher in group 2 than group 1 0.60% (confidence interval 95% 0.14-1.04). A significant increase of weight, body mass index, fat mass, albumin, prealbumin and transferrin was observed in both groups without statistical differences in this improvement between both groups. The increase of weight 4.59kg (confidence interval 95% 1.71-9.49) was higher in group 2 than group 1 1.46% (confidence interval 95% 0.39-2.54). Gastrointestinal tolerance (diarrhea episodes) with both formulas was good, without statistical differences (7.60% vs 7.14%: ns). A high monounsaturated fatty acid diabetes-specific supplement improved HbA1c and nutritional status. These improvements were higher with three supplements than with two per day.

  18. Parallel Expansions of Sox Transcription Factor Group B Predating the Diversifications of the Arthropods and Jawed Vertebrates

    Science.gov (United States)

    Zhong, Lei; Wang, Dengqiang; Gan, Xiaoni; Yang, Tong; He, Shunping

    2011-01-01

    Group B of the Sox transcription factor family is crucial in embryo development in the insects and vertebrates. Sox group B, unlike the other Sox groups, has an unusually enlarged functional repertoire in insects, but the timing and mechanism of the expansion of this group were unclear. We collected and analyzed data for Sox group B from 36 species of 12 phyla representing the major metazoan clades, with an emphasis on arthropods, to reconstruct the evolutionary history of SoxB in bilaterians and to date the expansion of Sox group B in insects. We found that the genome of the bilaterian last common ancestor probably contained one SoxB1 and one SoxB2 gene only and that tandem duplications of SoxB2 occurred before the arthropod diversification but after the arthropod-nematode divergence, resulting in the basal repertoire of Sox group B in diverse arthropod lineages. The arthropod Sox group B repertoire expanded differently from the vertebrate repertoire, which resulted from genome duplications. The parallel increases in the Sox group B repertoires of the arthropods and vertebrates are consistent with the parallel increases in the complexity and diversification of these two important organismal groups. PMID:21305035

  19. Role of signal dose preoperative antibiotic in acute nonperforated appendicitics

    International Nuclear Information System (INIS)

    Malik, S.A.; Rasheed, M.; Abbasi, A.S.; Iqbal, R.A.; Mian, M.A.

    2013-01-01

    Objective: To determine the efficacy of a single dose of preoperative antibiotic in preventing post operative infective complications in patients undergoing appendicectomy for non perforated acute appendicitis. Study Design: Randomized controlled trials. Place and Duration of Study: Surgical unit I and II, department of General Surgery, Combined Military Hospital (CMH) Lahore from 1st June to 31st October 2010. Patients and Methods: Seventy patients with acute appendicitis scheduled for appendicectomy were included in the study and randomly divided into two groups of 35 each using random numbers table. Group A received single dose preoperative antibiotic and group B received three-dose regimens of cefuroxime. Postoperative infective complications were the primary endpoint. Results: The rate of postoperative wound infection was not statistically insignificantly different among the groups; (8.57%) group A and (5.71%) group B at 1st post operative week and (5.71%) group A and (5.71%) group B at 2nd post operative week. None of the patients from either group showed any signs of intra abdominal abscess formation. Conclusion: Single dose of preoperative antibiotics is adequate for prevention of postoperative infective complications in patients with non-perforated appendicitis undergoing open appendicectomy. (author)

  20. A Pilot Study on Single-dose Toxicity Testing of Scolopendrid Pharmacopuncture in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Ilhong Son

    2014-06-01

    Full Text Available Objectives:This study was performed to analyze single dose toxicity and the lethal dose of Scolopendrid Pharmacopuncture in rats. Methods:All experiments were conducted at the Korea Testing & Research Institute (KTR, an institution authorized to perform non-clinical studies, under the regulations of Good Laboratory Practice (GLP. Sprague-Dawley rats were chosen for the pilot study. Doses of Scolopendrid pharmacopuncture, 0.1, 0.5, and 1.0 mL, were administered to the experimental group, and 1.0 mL doses of normal saline solution were administered to the control group. This study was conducted under the approval of the Institutional Animal Ethic Committee. Results:No deaths or abnormalities occurred in any of the groups. No significant changes in the weight, hematological parameters or clinical chemistry were noted between the control group and the experimental group. To check for abnormalities in organs and tissues, we used microscopy to examine representative histological sections of each specified organ; the results showed no significant differences in any of the organs or tissues. Conclusion:The above findings suggest Scolopendrid Pharmacopuncture is a relatively safe to use for treatment. Further studies on the subject should be conducted to yield more concrete evidence.

  1. Response of rat spinal cord to single and fractionated doses of accelerated heavy ions

    International Nuclear Information System (INIS)

    Leith, J.L.; McDonald, M.; Powers-Risius, P.; Bliven, S.F.; Walton, R.E.; Woodruff, K.H.; Howard, J.

    1980-01-01

    The response of rat spinal cord to irradiation with accelerated heavy ions, in particular carbon and neon ions has been studied. Two different ionization regions in the modified Bragg curve for each ion have been studied for both single and fractionated exposures. We have defined the paralytic response as a function of dose and dose per fraction, and we have determined RBE and repair values. The response of rat spinal cord is both dose and LET dependent, which allows the derivation of RBE and repair values

  2. Fluid dynamics parallel computer development at NASA Langley Research Center

    Science.gov (United States)

    Townsend, James C.; Zang, Thomas A.; Dwoyer, Douglas L.

    1987-01-01

    To accomplish more detailed simulations of highly complex flows, such as the transition to turbulence, fluid dynamics research requires computers much more powerful than any available today. Only parallel processing on multiple-processor computers offers hope for achieving the required effective speeds. Looking ahead to the use of these machines, the fluid dynamicist faces three issues: algorithm development for near-term parallel computers, architecture development for future computer power increases, and assessment of possible advantages of special purpose designs. Two projects at NASA Langley address these issues. Software development and algorithm exploration is being done on the FLEX/32 Parallel Processing Research Computer. New architecture features are being explored in the special purpose hardware design of the Navier-Stokes Computer. These projects are complementary and are producing promising results.

  3. Effect of single oral dose of tramadol on gastric secretions pH

    Directory of Open Access Journals (Sweden)

    Khan Mueen Ullah

    2015-01-01

    Full Text Available Background: Tramadol is an atypical analgesic agent. It has been shown that intramuscular or intravenous injection tramadol is able to inhibit M3 muscarinic receptors. Tramadol is able to mediate smooth muscles contraction and glandular secretions. We have evaluated the effects of single oral dose of tramadol given preoperatively on gastric juices pH in patients electively scheduled for laparoscopic cholecystectomy. Materials and Methods: Sixty adult, American Society of Anesthesiologist I and II patients scheduled for laparoscopic cholecystectomy were included in the study. Patients were randomly assigned to receive either placebo (n = 30 or oral tramadol 50 mg (n = 30. General anesthesia was induced using propofol, fentanyl and cisatracurium. After induction of anesthesia 5 ml of gastric fluid was aspirated through orogastric tube. The gastric fluid pH was measured using pH meter. Result: There was no significant difference in the pH between the groups. Gastric pH of the placebo and tramadol groups was 1.97 versus 1.98 (P = 0.092 respectively. Conclusion: Preoperatively single oral dose of tramadol was unable to elevate the desired level of gastric acid secretions pH (>2.5. This may be due to pharmacokinetic disparity between the analgesic and pH elevating properties of tramadol.

  4. Single therapeutic and supratherapeutic doses of sacubitril/valsartan (LCZ696) do not affect cardiac repolarization.

    Science.gov (United States)

    Langenickel, Thomas H; Jordaan, Pierre; Petruck, Jesika; Kode, Kiran; Pal, Parasar; Vaidya, Soniya; Chandra, Priya; Rajman, Iris

    2016-08-01

    Sacubitril/valsartan (LCZ696) is a first-in-class angiotensin receptor neprilysin inhibitor (ARNI) indicated to reduce the risk of cardiovascular death and hospitalization for heart failure in patients with chronic heart failure (NYHA class II-IV) and reduced ejection fraction. This study was aimed to evaluate the effect of single oral therapeutic (400 mg) and supratherapeutic (1200 mg) doses of LCZ696 on cardiac repolarization. This randomized double-blind crossover study in healthy male subjects compared the effect of therapeutic and supratherapeutic doses of LCZ696 with placebo and moxifloxacin 400 mg (open-label treatment) as positive control. The primary assessment was mean baseline- and placebo-corrected QTcF (∆∆QTcF; Fridericia correction). Additional assessments included the ∆∆QTcB (Bazett's correction), PR interval, QRS duration, heart rate (HR), LCZ696 pharmacokinetics, pharmacokinetic/pharmacodynamic relationships, and safety. Of the 84 subjects enrolled, 81 completed the study. The maximum upper bound of the two-sided 90 % confidence interval for ∆∆QTcF for LCZ696 400 mg and 1200 mg were <10 ms, and assay sensitivity was confirmed with moxifloxacin. No relevant treatment-emergent changes were observed in any of the ECG-derived parameters with LCZ696 or placebo, and the incidence of adverse events was comparable among the treatment groups. Single therapeutic and supratherapeutic doses of LCZ696 did not affect cardiac repolarization as defined by the E14 ICH guidelines.

  5. Dionis: A Novel Remote-Center-of-Motion Parallel Manipulator for Minimally Invasive Surgery

    Directory of Open Access Journals (Sweden)

    R. Beira

    2011-01-01

    Full Text Available The large volume and reduced dexterity of current surgical robotic systems are factors that restrict their effective performance. To improve the usefulness of surgical robots in minimally invasive surgery (MIS, a compact and accurate positioning mechanism, named Dionis, is proposed in this paper. This spatial hybrid mechanism based on a novel parallel kinematics is able to provide three rotations and one translation for single port procedures. The corresponding axes intersect at a remote center of rotation (RCM that is the MIS entry port. Another important feature of the proposed positioning manipulator is that it can be placed below the operating table plane, allowing a quick and direct access to the patient, without removing the robotic system. This, besides saving precious space in the operating room, may improve safety over existing solutions. The conceptual design of Dionis is presented in this paper. Solutions for the inverse and direct kinematics are developed, as well as the analytical workspace and singularity analysis. Due to its unique design and kinematics, the proposed mechanism is highly compact, stiff and its dexterity fullfils the workspace specifications for MIS procedures.

  6. Noise Estimation for Single-Slice Sinogram of Low-Dose X-Ray Computed Tomography Using Homogenous Patch

    Directory of Open Access Journals (Sweden)

    Zhiwu Liao

    2012-01-01

    Full Text Available We present a new method to estimate noise for a single-slice sinogram of low-dose CT based on the homogenous patches centered at a special pixel, called center point, which has the smallest variance among all sinogram pixels. The homogenous patch, composed by homogenous points, is formed by the points similar to the center point using similarity sorting, similarity decreasing searching, and variance analysis in a very large neighborhood (VLN to avoid manual selection of parameter for similarity measures.Homogenous pixels in the VLN allow us find the largest number of samples, who have the highest similarities to the center point, for noise estimation, and the noise level can be estimated according to unbiased estimation.Experimental results show that for the simulated noisy sinograms, the method proposed in this paper can obtain satisfied noise estimation results, especially for sinograms with relatively serious noises.

  7. Theoretical studies of one- and two-photon absorption properties for three molecules with different centers (B and N) and peripheral substituted groups [N(CH{sub 3}){sub 2} and CN

    Energy Technology Data Exchange (ETDEWEB)

    Han Deming [State Key Laboratory of Theoretical and Computational Chemistry, Institute of Theoretical Chemistry, Jilin University, Changchun 130023 (China); Feng Jikang, E-mail: jikangf@yahoo.co [State Key Laboratory of Theoretical and Computational Chemistry, Institute of Theoretical Chemistry, Jilin University, Changchun 130023 (China); College of Chemistry, Jilin University, Changchun 130023 (China); Ren Aimin [State Key Laboratory of Theoretical and Computational Chemistry, Institute of Theoretical Chemistry, Jilin University, Changchun 130023 (China); Shang Xiaohong [College of Chemistry, Jilin University, Changchun 130023 (China); Liu Xiaojuan [State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China)

    2009-08-15

    Three molecules with different centers (boron and nitrogen) and peripheral substituted groups [N(CH{sub 3}){sub 2} and CN] have been theoretically studied with B3LYP/6-31G(d) associated with ZINDO and sum-over-states methods. The maximum two-photon absorption cross-section delta{sub max} of the molecule with boron (B) center and N(CH{sub 3}){sub 2} peripheral group is larger than that of the molecule with nitrogen (N) center and N(CH{sub 3}){sub 2} peripheral group. As for the two molecules with N center, the delta{sub max} is obviously increased with the change from N(CH{sub 3}){sub 2} to CN group. This indicates that the large intramolecular charge transfer is in favor of the TPA response.

  8. On Symmetries of Extremal Black Holes with One and Two Centers

    CERN Document Server

    Ferrara, Sergio

    2013-01-01

    After a brief introduction to the Attractor Mechanism, we review the appearance of groups of type E7 as generalized electric-magnetic duality symmetries in locally supersymmetric theories of gravity, with particular emphasis on the symplectic structure of fluxes in the background of extremal black hole solutions, with one or two centers. In the latter case, the role of an "horizontal" symmetry SL(2,R) is elucidated by presenting a set of two-centered relations governing the structure of two-centered invariant polynomials.

  9. Response of rat spinal cord to single and fractionated doses of accelerated heavy ions

    International Nuclear Information System (INIS)

    Leith, J.T.; McDonald, M.; Powers-Risius, P.; Bliven, S.F.; Howard, J.

    1982-01-01

    The thoraco-lumbar (T12-L1) region of the spinal cord of rats was exposed to either single or fractionated (four daily exposures) doses of X rays (230 kVp) or heavy ions. The heavy ions used were carbon and neon, and the relative biological effectiveness (RBE) of both the plateau ionization region and the midpeak region of 4-cm spread-out Bragg peaks of each heavy ion were investigated. For single doses of carbon and neon ions in the plateau ionization region, RBE values of 1.45 +/- 0.25 (propagated 95% confidence limits) and 1.46 +/- 0.33, respectively, were obtained. In the spread peak regions for carbon and neon ions, the RBE values were 1.48 +/- 0.18 and 1.86 +/- 0.42, respectively. These values were obtained using the dose needed to produce 50% paralysis in a group of irradiated rats as the isoeffect comparison dose (ED 50 dose). Similarly, in groups of rats receiving four daily exposures, the RBE values for carbon and neon ions in the plateau ionization region were 1.31 +/- 0.27 and 1.80 +/- 0.24, respectively. In the spread peak regions of ionization for carbon and neon ions, the RBE values were 1.95 +/- 0.19 and 2.18 +/- 0.23, respectively. Similar values for RBE were obtained using changes in the activity of enzymes in spinal cord tissue (cyclic nucleotide phosphohydrolase and γ-glutamyl transpeptidase). Also, it was estimated that, for X irradiation, the fractional amount of dose repaired (at the ED 50 dose) was 0.64 +/- 0.10 (95% confidence limits). For carbon and neon ions in the plateau ionization region, the values for the fractional amount of dose repaired were 0.70 +/- 0.27 and 0.48 +/- 0.20, and for carbon and neon ions in the spread peak region of ionization, the fractional repair values were 0.40 +/- 0.10 and 0.52 +/- 0.17. Spinal cord tissue therefore shows a high capacity for subeffective damage repair

  10. Post-operative analgesia following total knee arthroplasty: comparison of low-dose intrathecal morphine and single-shot ultrasound-guided femoral nerve block: a randomized, single blinded, controlled study.

    Science.gov (United States)

    Frassanito, L; Vergari, A; Zanghi, F; Messina, A; Bitondo, M; Antonelli, M

    2010-07-01

    Total knee arthroplasty often results in marked postoperative pain. A recent meta-analysis supports the use of femoral nerve block or alternatively spinal injection of morphine plus local anaesthetic for post-operative analgesia. On the other hand, the use of intrathecal morphine may be associated with a large number of distressing side effects (itching, urinary retention, nausea and vomiting, delayed respiratory depression). The aim of this study was to compare the effectiveness of femoral nerve block and low dose intrathecal morphine in post-operative analgesia after primary unilateral total knee arthroplasty. Fifty-two consecutive patients scheduled for primary unilateral total knee arthroplasty were allocated to the intrathecal morphine group (ITM group) or to the femoral nerve block group (FNB group). In ITM group a subarachnoid puncture was performed at the L3-L4 inter-vertebral space with hyperbaric bupivacaine 15 mg plus 100 mcg of preservative-free morphine. Patients allocated to the FNB group received a single-injection ultrasound-assisted femoral nerve block with ropivacaine 0.75% 25 ml before the spinal injection of hyperbaric bupivacaine 15 mg. All patients received postoperative patient-controlled-analgesia (PCA) morphine, using a 1-mg bolus and a 5-minute lockout period. Data were analyzed using Student t test or two-way analysis of variance (ANOVA) for repeated measures with time and treatment as the 2 factors. Post hoc comparisons were performed by Bonferroni test. Statistical significance for all test was a p value < 0.05. Patient characteristics were similar between the 2 groups. We found a statistically significant differences in postoperative pain between the two groups: ITM group had the lower visual analogic pain score (VAS) values. Morphine consumption was lower in the ITM group: average consumption within the first 6 hours was 0.9 mg in IT group compared to 3.1 mg in FNB group; at 12 h 4.2 mg vs 6.3 mg; at 24 h 6.9 mg vs 10.3 mg; at 48 h 9

  11. Effects of two different high doses of irradiation on antioxidant system in the liver of guinea pigs.

    Science.gov (United States)

    Guney, Yildiz; Bukan, Neslihan; Dizman, Aysen; Hicsonmez, Ayse; Bilgihan, Ayse

    2004-03-01

    To examine the state of the oxidant-antioxidant system in the liver of guinea pig caused by high doses of ionizing radiation in the early period. The research was carried out on guinea pigs irradiated with the doses of 8 Gy (group 2) or 15 Gy (group 3) (single dose/whole body) in comparison with control group (group 1). The levels of thiobarbituric acid reactive substances (TBARS) and glutathione (GSH), the activities of superoxide dismutase (SOD), catalase (CAT), glutathione peroxidase (GSH-Px) and the levels of selenium in the liver were measured. TBARS levels in the irradiated animals were markedly higher than those in controls. In group 3, GSH levels and GSH-Px activity were significantly increased while activity of SOD and CAT were significantly decreased compared to groups 1 and 2. Liver selenium levels were not influenced by irradiation. The data have shown that gamma-irradiation at the doses of 8 Gy or 15 Gy results in significant increase in free radical formation while antioxidant enzymes were affected only at a dose of 15 Gy.

  12. Single and multiple dose Fluconazole in the treatment of candidia vulvovaginitis: a prospective comparative study

    Directory of Open Access Journals (Sweden)

    Ashrafinia M

    2007-09-01

    Full Text Available  Background: Vulvovaginal candidiasis, the most common type of vaginitis, is usually caused by Candidia albicans. Patients experience a variety of symptoms. There are many types of vulvovaginal candidiasis with various microbial causes, symptoms, host circumstances, recurrence rates, and responses to treatment. The purpose of this study was to find the best method of treatment of complicated vaginitis as determined by its high prevalence, varying symptoms and signs and patient complaints.Methods: In this open clinical trial without placebo control, we studied all patients aged 18 to 65 years, suffering from vaginitis symptoms that presented at the gynecological clinic of Arash Hospital, Tehran, Iran, during the year 2004. After obtaining informed consent, we assessed the response to a treatment of single 150 mg dose of fluconazole in one group, and sequential 150 mg doses of fluconazole in the other. The analysis was performed using SPSS statistical software (version 11.Results: With regard to symptom severity, no significant difference was found between the groups. The rate of excoriation and fissure formation demonstrated significant difference between the two groups (p=0.048. Assessment of clinical and mycological response proved that patients with severe vaginitis treated with sequential doses of fluconazole had a better general status than those in the other group. The difference between the severity of vaginitis and positive response to the treatment in culture was not significant among patients with recurrent vaginitis.Conclusion: Patients with mild to moderate recurrent vaginitis show better response to treatment. The high rate of positive culture on day 35 reconfirms the limitation of fluconazole and other azoles as fungistatic drugs.

  13. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-file Systems.

    Science.gov (United States)

    Prabhakar, Attiguppe R; Yavagal, Chandrashekar; Dixit, Kratika; Naik, Saraswathi V

    2016-01-01

    Primary root canals are considered to be most challenging due to their complex anatomy. "Wave one" and "one shape" are single-file systems with reciprocating and rotary motion respectively. The aim of this study was to evaluate and compare dentin thickness, centering ability, canal transportation, and instrumentation time of wave one and one shape files in primary root canals using a cone beam computed tomographic (CBCT) analysis. This is an experimental, in vitro study comparing the two groups. A total of 24 extracted human primary teeth with minimum 7 mm root length were included in the study. Cone beam computed tomographic images were taken before and after the instrumentation for each group. Dentin thickness, centering ability, canal transportation, and instrumentation times were evaluated for each group. A significant difference was found in instrumentation time and canal transportation measures between the two groups. Wave one showed less canal transportation as compared with one shape, and the mean instrumentation time of wave one was significantly less than one shape. Reciprocating single-file systems was found to be faster with much less procedural errors and can hence be recommended for shaping the root canals of primary teeth. How to cite this article: Prabhakar AR, Yavagal C, Dixit K, Naik SV. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-File Systems. Int J Clin Pediatr Dent 2016;9(1):45-49.

  14. Reliability of single aliquot regenerative protocol (SAR) for dose estimation in quartz at different burial temperatures: A simulation study

    International Nuclear Information System (INIS)

    Koul, D.K.; Pagonis, V.; Patil, P.

    2016-01-01

    The single aliquot regenerative protocol (SAR) is a well-established technique for estimating naturally acquired radiation doses in quartz. This simulation work examines the reliability of SAR protocol for samples which experienced different ambient temperatures in nature in the range of −10 to 40 °C. The contribution of various experimental variables used in SAR protocols to the accuracy and precision of the method is simulated for different ambient temperatures. Specifically the effects of paleo-dose, test dose, pre-heating temperature and cut-heat temperature on the accuracy of equivalent dose (ED) estimation are simulated by using random combinations of the concentrations of traps and centers using a previously published comprehensive quartz model. The findings suggest that the ambient temperature has a significant bearing on the reliability of natural dose estimation using SAR protocol, especially for ambient temperatures above 0 °C. The main source of these inaccuracies seems to be thermal sensitization of the quartz samples caused by the well-known thermal transfer of holes between luminescence centers in quartz. The simulations suggest that most of this inaccuracy in the dose estimation can be removed by delivering the laboratory doses in pulses (pulsed irradiation procedures). - Highlights: • Ambient temperatures affect the reliability of SAR. • It overestimates the dose with increase in burial temperature and burial time periods. • Elevated temperature irradiation does not correct for these overestimations. • Inaccuracies in dose estimation can be removed by incorporating pulsed irradiation procedures.

  15. Efficacy of praziquantel against Schistosoma mekongi and Opisthorchis viverrini: a randomized, single-blinded dose-comparison trial.

    Directory of Open Access Journals (Sweden)

    Leonore Lovis

    Full Text Available BACKGROUND: Schistosomiasis and opisthorchiasis are of public health importance in Southeast Asia. Praziquantel (PZQ is the drug of choice for morbidity control but few dose comparisons have been made. METHODOLOGY: Ninety-three schoolchildren were enrolled in an area of Lao PDR where Schistosoma mekongi and Opisthorchis viverrini coexist for a PZQ dose-comparison trial. Prevalence and intensity of infections were determined by a rigorous diagnostic effort (3 stool specimens, each examined with triplicate Kato-Katz before and 28-30 days after treatment. Ninety children with full baseline data were randomized to receive PZQ: the 40 mg/kg standard single dose (n = 45 or a 75 mg/kg total dose (50 mg/kg+25 mg/kg, 4 hours apart; n = 45. Adverse events were assessed at 3 and 24 hours posttreatment. PRINCIPAL FINDINGS: Baseline infection prevalence of S. mekongi and O. viverrini were 87.8% and 98.9%, respectively. S. mekongi cure rates were 75.0% (95% confidence interval (CI: 56.6-88.5% and 80.8% (95% CI: 60.6-93.4% for 40 mg/kg and 75 mg/kg PZQ, respectively (P = 0.60. O. viverrini cure rates were significantly different at 71.4% (95% CI: 53.4-84.4% and 96.6% (95% CI: not defined, respectively (P = 0.009. Egg reduction rates (ERRs against O. viverrini were very high for both doses (>99%, but slightly lower for S. mekongi at 40 mg/kg (96.4% vs. 98.1% and not influenced by increasing diagnostic effort. O. viverrini cure rates would have been overestimated and no statistical difference between doses found if efficacy was based on a minimum sampling effort (single Kato-Katz before and after treatment. Adverse events were common (96%, mainly mild with no significant differences between the two treatment groups. CONCLUSIONS/SIGNIFICANCE: Cure rate from the 75 mg/kg PZQ dose was more efficacious than 40 mg/kg against O. viverrini but not against S. mekongi infections, while ERRs were similar for both doses. TRIAL REGISTRATION: Controlled

  16. Pharmacokinetics of sulfamethoxazole and trimethoprim in Pacific white shrimp, Litopenaeus vannamei, after oral administration of single-dose and multiple-dose.

    Science.gov (United States)

    Ma, Rongrong; Wang, Yuan; Zou, Xiong; Hu, Kun; Sun, Beibei; Fang, Wenhong; Fu, Guihong; Yang, Xianle

    2017-06-01

    The tissue distribution and depletion of sulfamethoxazole (SMZ) and trimethoprim (TMP) were studied in Pacific white shrimp, Litopenaeus vannamei, after single-dose and multiple-dose oral administration of SMZ-TMP (5:1) via medicated feed. In single-dose oral administration, shrimps were fed once at a dose of 100 mg/kg (drug weight/body weight). In multiple-dose oral administration, shrimps were fed three times a day for three consecutive days at a dose of 100mg/kg. The results showed the kinetic characteristic of SMZ was different from TMP in Pacific white shrimp. In the single-dose administration, the SMZ was widely distributed in the tissues, while TMP was highly concentrated in the hepatopancreas. The t 1/2z values of SMZ were larger and persist longer than TMP in Pacific white shrimp. In the multiple-dose administration, SMZ accumulated well in the tissues, and reached steady state level after successive administrations, while TMP did not. TMP concentration even appeared the downward trend with the increase of drug times. Compared with the single dose, the t 1/2z values of SMZ in hepatopancreas (8.22-11.33h) and muscle (6.53-10.92h) of Pacific white shrimps rose, but the haemolymph dropped (13.76-11.03) in the multiple-dose oral administration. Meanwhile, the corresponding values of TMP also rose in hepatopancreas (4.53-9.65h) and muscle (2.12-2.71h), and declined in haemolymph (7.38-5.25h) following single-dose and multiple-dose oral administration in Pacific white shrimps. In addition, it is worth mentioning that the ratios of SMZ and TMP were unusually larger than the general aim ratio. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Conformal technique dose escalation in prostate cancer: improved cancer control with higher doses in patients with pretreatment PSA {>=} 10 ngm/ml

    Energy Technology Data Exchange (ETDEWEB)

    Hanks, G E; Lee, W R; Hanlon, A L; Kaplan, E; Epstein, B; Schultheiss, T

    1995-07-01

    Purpose: Single institutions and an NCI supported group of institutions have been investigating the value of dose escalation in patients with prostate cancer treated by conformal treatment techniques. Improvement in morbidity has been previously established, while this report identifies the pretreatment PSA level subgroups of patients who benefitted in cancer control from higher dose. Materials and Methods: We report actuarial bNED survival rates for 375 consecutive patients with known pretreatment PSA levels treated with conformal technique between 5/89 and 12/93. The whole pelvis was treated to 45 Gy in 25 fractions in all T2C,3, all Gleason 8, 9, 10 and all patients with pretreatment PSA {>=}20. The prostate {+-} seminal vesicles was boosted at 2.1 Gy/day to the center of the prostate to 65-79 Gy (65-69 N=50), 70-72.49 N=94, 72.5-74.9 N=82, 75-77.49 N=129 and {>=}77.5 N=20). The median followup is 21 mos with a range of 3 to 67 mos. The highest dose patients have the least followup, reducing the impact of the highest dose levels at this time. Patients are analyzed for the entire group divided at 71 Gy and at 73 Gy calculated at the center of the prostate. Each dose group is then subdivided by pretreatment PSA levels <10, 10-19.9, and {>=}20 ngm/ml and dose levels are compared within pretreatment PSA level group. bNED failure is defined as PSA {>=}1.5 ngm/ml and rising on two consecutive values. Results: Table 1 shows the bNED survival rates at 24 and 36 mos for all patients and the three pretreatment PSA level groups. For all patients pooled, there is an overall advantage to using doses {>=}71 Gy (64% vs 85% at 36 mo, p=.006) and {>=}73 Gy (71% vs 86% at 36 mo, p=.07). The subgroup of PSA <10 ngm/ml, however, shows no benefit in bNED survival when using doses over 71 Gy (90% vs 93% at 36 mo) or 73 Gy (91 vs 94% at 36 mo). The subgroup PSA 10 ngm/ml to 19.9 ngm/ml shows improved cancer control when using doses over 71 Gy (61% vs 88% at 36 mo, p=.03) and over 73

  18. A parallel algorithm for solving the multidimensional within-group discrete ordinates equations with spatial domain decomposition - 104

    International Nuclear Information System (INIS)

    Zerr, R.J.; Azmy, Y.Y.

    2010-01-01

    A spatial domain decomposition with a parallel block Jacobi solution algorithm has been developed based on the integral transport matrix formulation of the discrete ordinates approximation for solving the within-group transport equation. The new methodology abandons the typical source iteration scheme and solves directly for the fully converged scalar flux. Four matrix operators are constructed based upon the integral form of the discrete ordinates equations. A single differential mesh sweep is performed to construct these operators. The method is parallelized by decomposing the problem domain into several smaller sub-domains, each treated as an independent problem. The scalar flux of each sub-domain is solved exactly given incoming angular flux boundary conditions. Sub-domain boundary conditions are updated iteratively, and convergence is achieved when the scalar flux error in all cells meets a pre-specified convergence criterion. The method has been implemented in a computer code that was then employed for strong scaling studies of the algorithm's parallel performance via a fixed-size problem in tests ranging from one domain up to one cell per sub-domain. Results indicate that the best parallel performance compared to source iterations occurs for optically thick, highly scattering problems, the variety that is most difficult for the traditional SI scheme to solve. Moreover, the minimum execution time occurs when each sub-domain contains a total of four cells. (authors)

  19. Efficient bounding schemes for the two-center hybrid flow shop scheduling problem with removal times.

    Science.gov (United States)

    Hidri, Lotfi; Gharbi, Anis; Louly, Mohamed Aly

    2014-01-01

    We focus on the two-center hybrid flow shop scheduling problem with identical parallel machines and removal times. The job removal time is the required duration to remove it from a machine after its processing. The objective is to minimize the maximum completion time (makespan). A heuristic and a lower bound are proposed for this NP-Hard problem. These procedures are based on the optimal solution of the parallel machine scheduling problem with release dates and delivery times. The heuristic is composed of two phases. The first one is a constructive phase in which an initial feasible solution is provided, while the second phase is an improvement one. Intensive computational experiments have been conducted to confirm the good performance of the proposed procedures.

  20. Diagnosis of pulmonary artery embolism. Comparison of single-source CT and 3rd generation dual-source CT using a dual-energy protocol regarding image quality and radiation dose

    International Nuclear Information System (INIS)

    Petritsch, Bernhard; Kosmala, Aleksander; Gassenmeier, Tobias; Weng, Andreas Max; Veldhoen, Simon; Kunz, Andreas Steven; Bley, Thorsten Alexander

    2017-01-01

    To compare radiation dose, subjective and objective image quality of 3 rd generation dual-source CT (DSCT) and dual-energy CT (DECT) with conventional 64-slice single-source CT (SSCT) for pulmonary CTA. 180 pulmonary CTA studies were performed in three patient cohorts of 60 patients each. Group 1: conventional SSCT 120 kV (ref.); group 2: single-energy DSCT 100 kV (ref.); group 3: DECT 90/Sn150 kV. CTDIvol, DLP, effective radiation dose were reported, and CT attenuation (HU) was measured on three central and peripheral levels. The signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated. Two readers assessed subjective image quality according to a five-point scale. Mean CTDIvol and DLP were significantly lower in the dual-energy group compared to the SSCT group (p < 0.001 [CTDIvol]; p < 0.001 [DLP]) and the DSCT group (p = 0.003 [CTDIvol]; p = 0.003 [DLP]), respectively. The effective dose in the DECT group was 2.79 ± 0.95 mSv and significantly smaller than in the SSCT group (4.60 ± 1.68 mSv, p < 0.001) and the DSCT group (4.24 ± 2.69 mSv, p = 0.003). The SNR and CNR were significantly higher in the DSCT group (p < 0.001). Subjective image quality did not differ significantly among the three protocols and was rated good to excellent in 75 % (135/180) of cases with an inter-observer agreement of 80 %. Dual-energy pulmonary CTA protocols of 3 rd generation dual-source scanners allow for significant reduction of radiation dose while providing excellent image quality and potential additional information by means of perfusion maps. Dual-energy CT with 90/Sn150 kV configuration allows for significant dose reduction in pulmonary CTA. Subjective image quality was similar among the three evaluated CT-protocols (64-slice SSCT, single-energy DSCT, 90/Sn150 kV DECT) and was rated good to excellent in 75% of cases. Dual-energy CT provides potential additional information by means of iodine distribution maps.

  1. Two-dimensional superconducting state of monolayer Pb films grown on GaAs(110) in a strong parallel magnetic field.

    Science.gov (United States)

    Sekihara, Takayuki; Masutomi, Ryuichi; Okamoto, Tohru

    2013-08-02

    Two-dimensional (2D) superconductivity was studied by magnetotransport measurements on single-atomic-layer Pb films on a cleaved GaAs(110) surface. The superconducting transition temperature shows only a weak dependence on the parallel magnetic field up to 14T, which is higher than the Pauli paramagnetic limit. Furthermore, the perpendicular-magnetic-field dependence of the sheet resistance is almost independent of the presence of the parallel field component. These results are explained in terms of an inhomogeneous superconducting state predicted for 2D metals with a large Rashba spin splitting.

  2. Parallel education: what is it?

    OpenAIRE

    Amos, Michelle Peta

    2017-01-01

    In the history of education it has long been discussed that single-sex and coeducation are the two models of education present in schools. With the introduction of parallel schools over the last 15 years, there has been very little research into this 'new model'. Many people do not understand what it means for a school to be parallel or they confuse a parallel model with co-education, due to the presence of both boys and girls within the one institution. Therefore, the main obj...

  3. Parallel and distributed processing in two SGBDS: A case study

    Directory of Open Access Journals (Sweden)

    Francisco Javier Moreno

    2017-04-01

    Full Text Available Context: One of the strategies for managing large volumes of data is distributed and parallel computing. Among the tools that allow applying these characteristics are some Data Base Management Systems (DBMS, such as Oracle, DB2, and SQL Server. Method: In this paper we present a case study where we evaluate the performance of an SQL query in two of these DBMS. The evaluation is done through various forms of data distribution in a computer network with different degrees of parallelism. Results: The tests of the SQL query evidenced the performance differences between the two DBMS analyzed. However, more thorough testing and a wider variety of queries are needed. Conclusions: The differences in performance between the two DBMSs analyzed show that when evaluating this aspect, it is necessary to consider the particularities of each DBMS and the degree of parallelism of the queries.

  4. Ease of intubation: A randomized, double-blind study to compare two doses of rocuronium bromide for endotracheal intubation.

    Science.gov (United States)

    Shukla, Aparna; Misra, Shilpi

    2016-01-01

    Clinical need for a nondepolarizing agent with a rapid onset time and a brief duration of action has led to the development of rocuronium bromide. The aim of this study was to evaluate optimal dose of rocuronium bromide for intubation and to compare the onset time, duration of action, intubating conditions, and hemodynamic effects of two doses of rocuronium bromide. A prospective, randomized, double-blind study. All the patients were divided in a randomized, double-blind fashion into two groups of twenty patients each. Group I patients received rocuronium bromide 0.6 mg/kg intravenously and intubated at 60 s, Group II patients received rocuronium bromide 0.9 mg/kg and intubated at 60 s. The neuromuscular block was assessed using single twitch stimulation of 0.1 Hz at adductor pollicis muscle of hand at every 10 s. The results were compiled and analyzed statistically using Chi-square test for qualitative data and Student's t -test for quantitative data. Time of onset was significantly shorter ( P Rocuronium bromide 0.9 mg/kg is a safer alternative to rocuronium bromide 0.6 mg/kg for endotracheal intubation with shorter time of onset and better intubating conditions.

  5. Bioequivalence of fixed-dose combination RIN®-150 to each reference drug in loose combination.

    Science.gov (United States)

    Wang, H F; Wang, R; O'Gorman, M; Crownover, P; Damle, B

    2015-03-01

    RIN(®)-150 is a fixed-dose combination (FDC) tablet containing rifampicin (RMP, 150 mg) and isoniazid (INH, 75 mg) developed for the treatment of tuberculosis. This study was conducted at a single center: the Pfizer Clinical Research Unit in Singapore. To demonstrate bioequivalence of each drug component between RIN-150 and individual products in a loose combination. This was a randomized, open-label, single-dose, two-way crossover study. Subjects received single doses of RIN-150 or two individual reference products under fasting conditions in a crossover fashion, with at least 7 days washout between doses. The primary measures for comparison were peak plasma concentration (Cmax) and the area under plasma concentration-time curve (AUC). Of 28 subjects enrolled, 26 completed the study. The adjusted geometric mean ratios of Cmax and AUClast between the FDC and single-drug references and 90% confidence intervals were respectively 91.63% (90%CI 83.13-101.01) and 95.45% (90%CI 92.07-98.94) for RMP, and 107.58% (90%CI 96.07-120.47) and 103.45% (90%CI 99.33-107.75) for INH. Both formulations were generally well tolerated in this study. The RIN-150 FDC tablet formulation is bioequivalent to the two single-drug references for RMP and INH at equivalent doses.

  6. Bile duct evaluation of potential living liver donors with Gd-EOB-DTPA enhanced MR cholangiography: Single-dose, double dose or half-dose contrast enhanced imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja, E-mail: Sonja.Kinner@uni-due.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Steinweg, Verena [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Maderwald, Stefan [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Radtke, Arnold; Sotiropoulos, Georgios [Department of General Surgery, University Hospital Essen (Germany); Forsting, Michael; Schroeder, Tobias [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany)

    2014-05-15

    Introduction: Detailed knowledge of the biliary anatomy is essential to avoid complications in living donor liver transplantation. The aim of this study was to determine the optimal dosage of Gd-EOB-DTPA for contrast-enhanced magnetic resonance cholangiography (ce-MRC) with reference to contrast-enhanced CT cholangiography (ce-CTC). Materials and methods: 30 potential living liver donors (PLLD) underwent both ce-CTC and ce-MRC. Ten candidates each received single, double or half-dose Gd-EOB-DTPA. Ce-MRC images with and without inversion recovery pulses (T1w ± IR) were acquired 20–30 min after intravenous contrast injection. Image data was quantitatively and qualitatively reviewed by two radiologists based on a on a 5-point scale. Data sets were compared using a Mann–Whitney-U-test or Wilcoxon-rank-sum-test. Kappa values were also calculated. Results: All image series provided sufficient diagnostic information both showing normal biliary anatomy and variant bile ducts. Ce-CTC showed statistically significant better results compared to all ce-MRC data sets. T1w MRC with single dose Gd-EOB-DTPA proved to be superior to half and double dose in subjective and objective evaluation without a statistically significant difference. Conclusions: Ce-MRC is at any dosage inferior to ce-CTC. As far as preoperative planning of bile duct surgery is focused on the central biliary anatomy, ce-MRC can replace harmful ce-CTC strategies, anyway. Best results were seen with single dose GD-EOB-DTPA on T1w MRC+IR.

  7. Research on Two-channel Interleaved Two-stage Paralleled Buck DC-DC Converter for Plasma Cutting Power Supply

    DEFF Research Database (Denmark)

    Yang, Xi-jun; Qu, Hao; Yao, Chen

    2014-01-01

    As for high power plasma power supply, due to high efficiency and flexibility, multi-channel interleaved multi-stage paralleled Buck DC-DC Converter becomes the first choice. In the paper, two-channel interleaved two- stage paralleled Buck DC-DC Converter powered by three-phase AC power supply...

  8. The Effect of Nicotine Administration on Physical and Psychological Signs of Withdrawal Syndrome Induced by Single or Frequent Doses of Morphine in Rats

    OpenAIRE

    Mohammad Allahtavakoli; Fatemeh Amin; Elham Hakimizadeh; Ali Roohbakhsh; Sayed Ali Haeri Rohani; Ahmad Taghavi Rafsanjani; Abbas Haghparast; Ali Shamsizadeh

    2012-01-01

    Introduction. Morphine addiction and morphine withdrawal syndrome are the two main problems of today’s human society. The present study has investigated the effects of nicotine on the strength of physical and psychological dependency in single and repeated doses morphine administrated rats. Materials and methods. Male Wistar rats were subjected to morphine consumption with single or frequent dose protocols. In the single dose protocol, rats received only one dose of morphine and 24hrs later t...

  9. Are drowned donors marginal donors? A single pediatric center experience.

    Science.gov (United States)

    Kumm, Kayla R; Galván, N Thao N; Koohmaraie, Sarah; Rana, Abbas; Kueht, Michael; Baugh, Katherine; Hao, Liu; Yoeli, Dor; Cotton, Ronald; O'Mahony, Christine A; Goss, John A

    2017-09-01

    Drowning, a common cause of death in the pediatric population, is a potentially large donor pool for OLT. Anecdotally, transplant centers have deemed these organs high risk over concerns for infection and graft dysfunction. We theorized drowned donor liver allografts do not portend worse outcomes and therefore should not be excluded from the donation pool. We reviewed our single-center experience of pediatric OLTs between 1988 and 2015 and identified 33 drowned donor recipients. These OLTs were matched 1:2 to head trauma donor OLTs from our center. A chart review assessed postoperative peak AST and ALT, incidence of HAT, graft and recipient survival. Recipient survival at one year between patients with drowned donor vs head trauma donor allografts was not statistically significant (94% vs 97%, P=.63). HAT incidence was 6.1% in the drowned donor group vs 7.6% in the control group (P=.78). Mean postoperative peak AST and ALT was 683 U/L and 450 U/L for drowned donors vs 1119 U/L and 828 U/L in the matched cohort. These results suggest drowned donor liver allografts do not portend worse outcomes in comparison with those procured from head trauma donors. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Single Dose Toxicity of Chukyu (spine-healing Pharmacopuncture Injection in the Muscle of Rats

    Directory of Open Access Journals (Sweden)

    Jeong Hohyun

    2014-03-01

    Full Text Available Objectives: This study was performed to analyze the single dose toxicity of Chukyu (spine-healing pharmacopuncture. Methods: All experiments were conducted at the Biotoxtech, an institution authorized to perform non-clinical studies under the regulations of Good Laboratory Practice (GLP regulations. Sprague-Dawley rats were chosen for the pilot study. Doses of Chukyu (spine-healing pharmacopuncture, 0.1, 0.5 and 1.0 mL, were administered to the experimental groups, and a dose of normal saline solution, 1.0 mL, was administered to the control group. This study was conducted under the approval of the Institutional Animal Ethic Committee. Results: No deaths or abnormalities occurred in any of the four groups. No significant changes in weight, hematological parameters or clinical chemistry between the control group and the experimental groups were observed. To check for abnormalities in organs and tissues, we used microscopy to examine representative histological sections of each specified organ; the results showed no significant differences in any of the organs or tissues except in one case, where interstitial infiltrating macrophages were found in one female rat in the 0.5-mL/animal experimental group. Conclusion: The above findings suggest that treatment with Chukyu (spine-healing pharmacopuncture is relatively safe. Further studies on this subject are needed to yield more concrete evidence.

  11. Safety and pharmacodynamics of venetoclax (ABT-199) in a randomized single and multiple ascending dose study in women with systemic lupus erythematosus.

    Science.gov (United States)

    Lu, P; Fleischmann, R; Curtis, C; Ignatenko, S; Clarke, S H; Desai, M; Wong, S L; Grebe, K M; Black, K; Zeng, J; Stolzenbach, J; Medema, J K

    2018-02-01

    Objective The anti-apoptotic protein B-cell lymphoma 2 (Bcl-2) may contribute to the pathogenesis of systemic lupus erythematosus. The safety, tolerability, and pharmacodynamics of the selective Bcl-2 inhibitor venetoclax (ABT-199) were assessed in women with systemic lupus erythematosus. Methods A phase 1, double-blind, randomized, placebo controlled study evaluated single ascending doses (10, 30, 90, 180, 300, and 500 mg) and multiple ascending doses (2 cycles; 30, 60, 120, 240, 400, and 600 mg for 1 week, and then 3 weeks off per cycle) of orally administered venetoclax. Eligible participants were aged 18-65 years with a diagnosis of systemic lupus erythematosus for 6 months or more receiving stable therapy for systemic lupus erythematosus (which could have included corticosteroids and/or stable antimalarials). Results All patients (48/48) completed the single ascending dose, 25 continued into the multiple ascending dose, and 44/50 completed the multiple ascending dose; two of the withdrawals (venetoclax 60 mg and 600 mg cohorts) were due to adverse events. Adverse event incidences were slightly higher in the venetoclax groups compared with the placebo groups, with no dose dependence. There were no serious adverse events with venetoclax. The most common adverse events were headache, nausea, and fatigue. Venetoclax 600 mg multiple ascending dose treatment depleted total lymphocytes and B cells by approximately 50% and 80%, respectively. Naive, switched memory, and memory B-cell subsets enriched in autoreactive B cells exhibited dose-dependent reduction of up to approximately 80%. There were no consistent or marked changes in neutrophils, natural killer cells, hemoglobin, or platelets. Conclusions Venetoclax was generally well tolerated in women with systemic lupus erythematosus and reduced total lymphocytes and disease-relevant subsets of antigen-experienced B cells. Registration ClinicalTrials.gov: NCT01686555.

  12. Beyond silence: protocol for a randomized parallel-group trial comparing two approaches to workplace mental health education for healthcare employees.

    Science.gov (United States)

    Moll, Sandra; Patten, Scott Burton; Stuart, Heather; Kirsh, Bonnie; MacDermid, Joy Christine

    2015-04-16

    Mental illness is a significant and growing problem in Canadian healthcare organizations, leading to tremendous personal, social and financial costs for individuals, their colleagues, their employers and their patients. Early and appropriate intervention is needed, but unfortunately, few workers get the help that they need in a timely way due to barriers related to poor mental health literacy, stigma, and inadequate access to mental health services. Workplace education and training is one promising approach to early identification and support for workers who are struggling. Little is known, however, about what approach is most effective, particularly in the context of healthcare work. The purpose of this study is to compare the impact of a customized, contact-based education approach with standard mental health literacy training on the mental health knowledge, stigmatized beliefs and help-seeking/help-outreach behaviors of healthcare employees. A multi-centre, randomized, two-group parallel group trial design will be adopted. Two hundred healthcare employees will be randomly assigned to one of two educational interventions: Beyond Silence, a peer-led program customized to the healthcare workplace, and Mental Health First Aid, a standardized literacy based training program. Pre, post and 3-month follow-up surveys will track changes in knowledge (mental health literacy), attitudes towards mental illness, and help-seeking/help-outreach behavior. An intent-to-treat, repeated measures analysis will be conducted to compare changes in the two groups over time in terms of the primary outcome of behavior change. Linear regression modeling will be used to explore the extent to which knowledge, and attitudes predict behavior change. Qualitative interviews with participants and leaders will also be conducted to examine process and implementation of the programs. This is one of the first experimental studies to compare outcomes of standard mental health literacy training to an

  13. Linear predictions of supercritical flow instability in two parallel channels

    International Nuclear Information System (INIS)

    Shah, M.

    2008-01-01

    A steady state linear code that can predict thermo-hydraulic instability boundaries in a two parallel channel system under supercritical conditions has been developed. Linear and non-linear solutions of the instability boundary in a two parallel channel system are also compared. The effect of gravity on the instability boundary in a two parallel channel system, by changing the orientation of the system flow from horizontal flow to vertical up-flow and vertical down-flow has been analyzed. Vertical up-flow is found to be more unstable than horizontal flow and vertical down flow is found to be the most unstable configuration. The type of instability present in each flow-orientation of a parallel channel system has been checked and the density wave oscillation type is observed in horizontal flow and vertical up-flow, while the static type of instability is observed in a vertical down-flow for the cases studied here. The parameters affecting the instability boundary, such as the heating power, inlet temperature, inlet and outlet K-factors are varied to assess their effects. This study is important for the design of future Generation IV nuclear reactors in which supercritical light water is proposed as the primary coolant. (author)

  14. Interaction between single-dose Mycoplasma hyopneumoniae and porcine reproductive and respiratory syndrome virus vaccines on dually infected pigs.

    Science.gov (United States)

    Park, Su-Jin; Seo, Hwi Won; Park, Changhoon; Chae, Chanhee

    2014-06-01

    The objective of this study was to determine the effects of Mycoplasma hyopneumoniae and/or porcine reproductive and respiratory syndrome virus (PRRSV) vaccination on dually infected pigs. In total, 72 pigs were randomly divided into nine groups (eight pigs per group), as follows: five vaccinated and challenged groups, three non-vaccinated and challenged groups, and a negative control group. Single-dose vaccination against M. hyopneumoniae alone decreased the levels of PRRSV viremia and PRRSV-induced pulmonary lesions, whereas single-dose vaccination against PRRSV alone did not decrease nasal shedding of M. hyopneumoniae and mycoplasma-induced pulmonary lesions in the dually infected pigs. The M. hyopneumoniae challenge impaired the protective cell-mediated immunity induced by the PRRSV vaccine, whereas the PRRSV challenge did not impair the protective cell-mediated immunity induced by the M. hyopneumoniae vaccine. The present study provides swine practitioners and producers with efficient vaccination regimes; vaccination against M. hyopneumoniae is the first step in protecting pigs against co-infection with M. hyopneumoniae and PRRSV. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Impact of benzodiazepines on brain FDG-PET quantification after single-dose and chronic administration in rats

    International Nuclear Information System (INIS)

    Silva-Rodríguez, Jesús; García-Varela, Lara; López-Arias, Esteban; Domínguez-Prado, Inés; Cortés, Julia; Pardo-Montero, Juan; Fernández-Ferreiro, Anxo

    2016-01-01

    Introduction: Current guidelines for brain PET imaging advice against the injection of diazepam prior to brain FDG-PET examination in order to avoid possible interactions of benzodiazepines with the radiotracer uptake. Nevertheless, many patients undergoing PET studies are likely to be under chronic treatment with benzodiazepines, for example due to the use of different medications such as sleeping pills. Animal studies may provide an extensive and accurate estimation of the effect of benzodiazepines on brain metabolism in a well-defined and controlled framework. Aim: This study aims at evaluating the impact of benzodiazepines on brain FDG uptake after single-dose administration and chronic treatment in rats. Methods: Twelve Sprague–Dawley healthy rats were randomly divided into two groups, one treated with diazepam and the other used as control group. Both groups underwent PET/CT examinations after single-dose and chronic administration of diazepam (treated) or saline (controls) during twenty-eight days. Different atlas-based quantification methods were used to explore differences on the total uptake and uptake patterns of FDG between both groups. Results: Our analysis revealed a significant reduction of global FDG uptake after acute (−16.2%) and chronic (−23.2%) administration of diazepam. Moreover, a strong trend pointing to differences between acute and chronic administrations (p < 0.08) was also observed. Uptake levels returned to normal after interrupting the administration of diazepam. On the other hand, patterns of FDG uptake were not affected by the administration of diazepam. Conclusions: The administration of diazepam causes a progressive decrease of the FDG global uptake in the rat brain, but it does not change local patterns within the brain. Under these conditions, visual assessment and quantification methods based on regional differences such as asymmetry indexes or SPM statistical analysis would still be valid when administrating this

  16. Teaching Scientific Computing: A Model-Centered Approach to Pipeline and Parallel Programming with C

    Directory of Open Access Journals (Sweden)

    Vladimiras Dolgopolovas

    2015-01-01

    Full Text Available The aim of this study is to present an approach to the introduction into pipeline and parallel computing, using a model of the multiphase queueing system. Pipeline computing, including software pipelines, is among the key concepts in modern computing and electronics engineering. The modern computer science and engineering education requires a comprehensive curriculum, so the introduction to pipeline and parallel computing is the essential topic to be included in the curriculum. At the same time, the topic is among the most motivating tasks due to the comprehensive multidisciplinary and technical requirements. To enhance the educational process, the paper proposes a novel model-centered framework and develops the relevant learning objects. It allows implementing an educational platform of constructivist learning process, thus enabling learners’ experimentation with the provided programming models, obtaining learners’ competences of the modern scientific research and computational thinking, and capturing the relevant technical knowledge. It also provides an integral platform that allows a simultaneous and comparative introduction to pipelining and parallel computing. The programming language C for developing programming models and message passing interface (MPI and OpenMP parallelization tools have been chosen for implementation.

  17. Increased apoptotic potential and dose-enhancing effect of gold nanoparticles in combination with single-dose clinical electron beams on tumor-bearing mice

    International Nuclear Information System (INIS)

    Chang Mengya; Chen Yuhung; Chang Chihjui; Chen Helen H-W; Wu Chaoliang; Shiau Aili

    2008-01-01

    High atomic number material, such as gold, may be used in conjunction with radiation to provide dose enhancement in tumors. In the current study, we investigated the dose-enhancing effect and apoptotic potential of gold nanoparticles in combination with single-dose clinical electron beams on B16F10 melanoma tumor-bearing mice. We revealed that the accumulation of gold nanoparticles was detected inside B16F10 culture cells after 18 h of incubation, and moreover, the gold nanoparticles were shown to be colocalized with endoplasmic reticulum and Golgi apparatus in cells. Furthermore, gold nanoparticles radiosensitized melanoma cells in the colony formation assay (P=0.02). Using a B16F10 tumor-bearing mouse model, we further demonstrated that gold nanoparticles in conjunction with ionizing radiation significantly retarded tumor growth and prolonged survival compared to the radiation alone controls (P<0.05). Importantly, an increase of apoptotic signals was detected inside tumors in the combined treatment group (P<0.05). Knowing that radiation-induced apoptosis has been considered a determinant of tumor responses to radiation therapy, and the length of tumor regrowth delay correlated with the extent of apoptosis after single-dose radiotherapy, these results may suggest the clinical potential of gold nanoparticles in improving the outcome of melanoma radiotherapy. (author)

  18. Single event effects and total ionizing dose effects of typical VDMOSFET devices

    International Nuclear Information System (INIS)

    Lou Jianshe; Cai Nan; Liu Jiaxin; Wu Qinzhi; Wang Jia

    2012-01-01

    In this work, single event effects and total ionizing dose effects of typical VDMOSFET irradiated by 60 Co γ-rays and 252 Cf source were studied. The single event burnout and single event gate rupture (SEB/SEGR) effects were investigated, and the relationship between drain-source breakdown voltage and ionizing dose was obtained. The results showed that the VDMOSFET devices were sensitive to SEB and SEGR, and measures to improve their resistance to SEB and SEGR should be considered seriously for their space applications. The drain-source breakdown voltage was sensitive to total ionizing dose effects as the threshold voltage. In assessing the devices' resistance to the total ionizing dose effects, both the threshold voltage and the drain-source breakdown voltage should be taken into account. (authors)

  19. GSK1265744 pharmacokinetics in plasma and tissue after single-dose long-acting injectable administration in healthy subjects.

    Science.gov (United States)

    Spreen, William; Ford, Susan L; Chen, Shuguang; Wilfret, David; Margolis, David; Gould, Elizabeth; Piscitelli, Stephen

    2014-12-15

    GSK1265744 (744) is an HIV-1 integrase inhibitor in clinical development as a long-acting (LA) injectable formulation. This study evaluated plasma and tissue pharmacokinetics after single-dose administration of 744 LA administered by intramuscular (IM) or subcutaneous injections. This was a phase I, open-label, 9-cohort, parallel study of 744 in healthy subjects. 744 was administered as a 200 mg/mL nanosuspension at doses of 100-800 mg IM and 100-400 mg subcutaneous. Eight (6 active and 2 placebo) male and female subjects participated in each of the first 7 cohorts. All 8 subjects, 4 males and 4 females, received active 744 LA in cohorts 8 and 9 and underwent rectal and cervicovaginal tissue sampling, respectively. Plasma pharmacokinetic sampling was performed for a minimum of 12 weeks or until 744 concentrations were ≤0.1 μg/mL. Rectal and cervicovaginal tissue biopsies were performed at weeks 2 and 8 (cohort 8) and weeks 4 and 12 (cohort 9). 744 LA was generally safe and well tolerated after single injections. A majority of subjects reported injection site reactions, all graded as mild in intensity. Plasma concentration-time profiles were prolonged with measureable concentrations up to 52 weeks after dosing. 744 LA 800 mg IM achieved mean concentrations above protein adjusted-IC90 for approximately 16 weeks. Rectal and cervicovaginal tissue concentrations ranged from injection has potential application as a monthly or less frequent HIV treatment or prevention agent.

  20. Clinical Efficacy of a Single Two Gram Dose of Azithromycin Extended Release for Male Patients with Urethritis

    Directory of Open Access Journals (Sweden)

    Satoshi Takahashi

    2014-04-01

    Full Text Available To clarify the clinical efficacy of a single oral 2 g dose of azithromycin extended-release for heterosexual male patients with urethritis, and the current antimicrobial sensitivity of Neisseria gonorrhoeae to azithromycin, a prospective clinical trial was conducted from 2011–2013. In patients with gonococcal urethritis, the eradication rate was 90.9% (30 of 33. The susceptibility rates of isolated Neisseria gonorrhoeae strains to ceftriaxone, spectinomycin, cefixime and azithromycin were 100%, 100%, 95.3% (41/43 and 37.2% (16/43, respectively. In the patients with nongonococcal urethritis, the eradication rate was 90.0% (45 of 50. The microbiological eradication rates for the pathogens were 90.9% (30/33 for Neisseria gonorrhoeae, 91.5% (43/47 for Chlamydia trachomatis, 71.4% (5/7 for Mycoplasma genitalium, and 100% (13/13 for Ureaplasma urealyticum. The main adverse event was diarrhea and its manifestation rate was 35.2% (32 of 120. The symptom of diarrhea was mostly temporary and resolved spontaneously. The conclusion was that the treatment regimen with a single oral 2 g dose of azithromycin extended-release would be effective for patients with urethritis. However, the antimicrobial susceptibilities of Neisseria gonorrhoeae and Mycoplasma genitalium should be carefully monitored because of possible treatment failure.

  1. Clinical Efficacy of a Single Two Gram Dose of Azithromycin Extended Release for Male Patients with Urethritis.

    Science.gov (United States)

    Takahashi, Satoshi; Kiyota, Hiroshi; Ito, Shin; Iwasawa, Akihiko; Hiyama, Yoshiki; Uehara, Teruhisa; Ichihara, Koji; Hashimoto, Jiro; Masumori, Naoya; Sunaoshi, Kenichi; Takeda, Koichi; Suzuki, Nobukazu; Hosobe, Takahide; Goto, Hirokazu; Suzuki, Hidenori; Onodera, Shoichi

    2014-04-02

    To clarify the clinical efficacy of a single oral 2 g dose of azithromycin extended-release for heterosexual male patients with urethritis, and the current antimicrobial sensitivity of Neisseria gonorrhoeae to azithromycin, a prospective clinical trial was conducted from 2011-2013. In patients with gonococcal urethritis, the eradication rate was 90.9% (30 of 33). The susceptibility rates of isolated Neisseria gonorrhoeae strains to ceftriaxone, spectinomycin, cefixime and azithromycin were 100%, 100%, 95.3% (41/43) and 37.2% (16/43), respectively. In the patients with nongonococcal urethritis, the eradication rate was 90.0% (45 of 50). The microbiological eradication rates for the pathogens were 90.9% (30/33) for Neisseria gonorrhoeae, 91.5% (43/47) for Chlamydia trachomatis, 71.4% (5/7) for Mycoplasma genitalium, and 100% (13/13) for Ureaplasma urealyticum. The main adverse event was diarrhea and its manifestation rate was 35.2% (32 of 120). The symptom of diarrhea was mostly temporary and resolved spontaneously. The conclusion was that the treatment regimen with a single oral 2 g dose of azithromycin extended-release would be effective for patients with urethritis. However, the antimicrobial susceptibilities of Neisseria gonorrhoeae and Mycoplasma genitalium should be carefully monitored because of possible treatment failure.

  2. Diagnosis of pulmonary artery embolism. Comparison of single-source CT and 3{sup rd} generation dual-source CT using a dual-energy protocol regarding image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Petritsch, Bernhard; Kosmala, Aleksander; Gassenmeier, Tobias; Weng, Andreas Max; Veldhoen, Simon; Kunz, Andreas Steven; Bley, Thorsten Alexander [Univ. Hospital Wuerzburg (Germany). Inst. of Diagnostic and Interventional Radiology

    2017-06-15

    To compare radiation dose, subjective and objective image quality of 3 rd generation dual-source CT (DSCT) and dual-energy CT (DECT) with conventional 64-slice single-source CT (SSCT) for pulmonary CTA. 180 pulmonary CTA studies were performed in three patient cohorts of 60 patients each. Group 1: conventional SSCT 120 kV (ref.); group 2: single-energy DSCT 100 kV (ref.); group 3: DECT 90/Sn150 kV. CTDIvol, DLP, effective radiation dose were reported, and CT attenuation (HU) was measured on three central and peripheral levels. The signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated. Two readers assessed subjective image quality according to a five-point scale. Mean CTDIvol and DLP were significantly lower in the dual-energy group compared to the SSCT group (p < 0.001 [CTDIvol]; p < 0.001 [DLP]) and the DSCT group (p = 0.003 [CTDIvol]; p = 0.003 [DLP]), respectively. The effective dose in the DECT group was 2.79 ± 0.95 mSv and significantly smaller than in the SSCT group (4.60 ± 1.68 mSv, p < 0.001) and the DSCT group (4.24 ± 2.69 mSv, p = 0.003). The SNR and CNR were significantly higher in the DSCT group (p < 0.001). Subjective image quality did not differ significantly among the three protocols and was rated good to excellent in 75 % (135/180) of cases with an inter-observer agreement of 80 %. Dual-energy pulmonary CTA protocols of 3 rd generation dual-source scanners allow for significant reduction of radiation dose while providing excellent image quality and potential additional information by means of perfusion maps. Dual-energy CT with 90/Sn150 kV configuration allows for significant dose reduction in pulmonary CTA. Subjective image quality was similar among the three evaluated CT-protocols (64-slice SSCT, single-energy DSCT, 90/Sn150 kV DECT) and was rated good to excellent in 75% of cases. Dual-energy CT provides potential additional information by means of iodine distribution maps.

  3. RAPP, a systematic e-assessment of postoperative recovery in patients undergoing day surgery: study protocol for a mixed-methods study design including a multicentre, two-group, parallel, single-blind randomised controlled trial and qualitative interview studies.

    Science.gov (United States)

    Nilsson, U; Jaensson, M; Dahlberg, K; Odencrants, S; Grönlund, Å; Hagberg, L; Eriksson, M

    2016-01-13

    Day surgery is a well-established practice in many European countries, but only limited information is available regarding postoperative recovery at home though there is a current lack of a standard procedure regarding postoperative follow-up. Furthermore, there is also a need for improvement of modern technology in assessing patient-related outcomes such as mobile applications. This article describes the Recovery Assessment by Phone Points (RAPP) study protocol, a mixed-methods study to evaluate if a systematic e-assessment follow-up in patients undergoing day surgery is cost-effective and improves postoperative recovery, health and quality of life. This study has a mixed-methods study design that includes a multicentre, two-group, parallel, single-blind randomised controlled trial and qualitative interview studies. 1000 patients >17 years of age who are undergoing day surgery will be randomly assigned to either e-assessed postoperative recovery follow-up daily in 14 days measured via smartphone app including the Swedish web-version of Quality of Recovery (SwQoR) or to standard care (ie, no follow-up). The primary aim is cost-effectiveness. Secondary aims are (A) to explore whether a systematic e-assessment follow-up after day surgery has a positive effect on postoperative recovery, health-related quality of life (QoL) and overall health; (B) to determine whether differences in postoperative recovery have an association with patient characteristic, type of surgery and anaesthesia; (C) to determine whether differences in health literacy have a substantial and distinct effect on postoperative recovery, health and QoL; and (D) to describe day surgery patient and staff experiences with a systematic e-assessment follow-up after day surgery.The primary aim will be measured at 2 weeks postoperatively and secondary outcomes (A-C) at 1 and 2 weeks and (D) at 1 and 4 months. NCT02492191; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use

  4. Conditioned instrumental behaviour in the rat: Effects of prenatal irradiation with various low dose-rate doses

    International Nuclear Information System (INIS)

    Klug, H.

    1986-01-01

    4 groups of rats of the Wistar-strain were subjected to γ-irradiation on the 16th day of gestation. 5 rats received 0,6 Gy low dose rate irradiation, 5 animals received 0,9 Gy low dose and 6 high dose irradiation, 3 females were shamirradiated. The male offspring of these 3 irradiation groups and 1 control group were tested for locomotor coordination on parallel bars and in a water maze. The female offspring were used in an operant conditioning test. The locomotor test showed slight impairment of locomotor coordination in those animals irradiated with 0,9 Gy high dose rate. Swimming ability was significantly impaired by irradiation with 0,9 Gy high dose rate. Performance in the operant conditioning task was improved by irradiation with 0,9 Gy both low and high dose rate. The 0,9 Gy high dose rate group learned faster than all the other groups. For the dose of 0,9 Gy a significant dose rate effect could be observed. For the dose of 0,6 Gy a similar tendency was observed, differences between 0,6 Gy high and low dose rate and controls not being significant. (orig./MG) [de

  5. Efficiency of early, single-dose probiotic administration methods on performance, small intestinal morphology, blood biochemistry, and immune response of Japanese quail.

    Science.gov (United States)

    Seifi, Kazem; Karimi Torshizi, Mohammad Amir; Rahimi, Shaban; Kazemifard, Mohammad

    2017-07-01

    The aim of the present study was to investigate the efficacy of early probiotics (single dose) administered in different ways, on quails' performance, small intestine morphology, blood biochemistry, and immune response. In total, 192 day-old chicks were used in one of the following experimental groups before being transferred to a raising room: 1) Control (no probiotic administered), 2) oral gavage, 3) spray, and 4) vent lip. Four replicates of 12 chicks per cage were considered for each treatment and birds were raised up to 35 d in the same conditions. Probiotic treated birds had higher d 1 to 35 feed intake than the control group (P birds had a higher body weight gain as compared to the control (P birds compared to control (P  0.01). None of the immune-related parameters were affected by the probiotic (P > 0.05). Single dose usage of probiotics exerts its beneficial effects on quails' body weight gain, feed intake and mortality in 1 to 35 d period, regardless of the route of administration. This work generally supports the efficacy of single-dose usage of probiotics and suggests the spray of probiotics as an early, single-dose administration method. © 2017 Poultry Science Association Inc.

  6. Blood phenylalanine concentrations in patients with PAH-deficient hyperphenylalaninaemia off diet without and with three different single oral doses of tetrahydrobiopterin: assessing responsiveness in a model of statistical process control.

    Science.gov (United States)

    Lindner, M; Gramer, G; Garbade, S F; Burgard, P

    2009-08-01

    Tetrahydrobiopterin (BH(4)) cofactor loading is a standard procedure to differentiate defects of BH(4) metabolism from phenylalanine hydroxylase (PAH) deficiency. BH(4) responsiveness also exists in PAH-deficient patients with high residual PAH activity. Unexpectedly, single cases with presumed nil residual PAH activity have been reported to be BH(4) responsive, too. BH(4) responsiveness has been defined either by a >or=30% reduction of blood Phe concentration after a single BH(4) dose or by a decline greater than the individual circadian Phe level variation. Since both methods have methodological disadvantages, we present a model of statistical process control (SPC) to assess BH(4) responsiveness. Phe levels in 17 adult PKU patients of three phenotypic groups off diet were compared without and with three different single oral dosages of BH(4) applied in a double-blind randomized cross-over design. Results are compared for >or=30% reduction and SPC. The effect of BH(4) by >or=30% reduction was significant for groups (p < 0.01) but not for dose (p = 0.064), with no interaction of group with dose (p = 0.24). SPC revealed significant effects for group (p < 0.01) and the interaction for group with dose (p < 0.05) but not for dose alone (p = 0.87). After one or more loadings, seven patients would be judged to be BH(4) responsive either by the 30% criterion or by the SPC model, but only three by both. Results for patients with identical PAH genotype were not very consistent within (for different BH(4) doses) and between the two models. We conclude that a comparison of protein loadings without and with BH(4) combined with a standardized procedure for data analysis and decision would increase the reliability of diagnostic results.

  7. Single Stator Dual PM Rotor Synchronous Machine with two-frequency single-inverter control, for the propulsion of hybrid electric vehicles

    Directory of Open Access Journals (Sweden)

    Topor Marcel

    2017-01-01

    Full Text Available This paper introduces a novel brushless, single winding and single stator, dual PM rotor axial-air-gap machine capable to deliver independently torque at the two rotors by adequate dual vector control. The proposed topologies, the circuit model, controlled dynamics simulation and preliminary 3D FEM torque production on a case study constitute the core of the paper. The proposed dual mechanical port system should be instrumental in parallel (with planetary gears or series hybrid electric vehicles (HEV aiming at a more compact and efficient electric propulsion system solution.

  8. The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Pt. 7. Organ doses due to parallel and environmental exposure geometries

    Energy Technology Data Exchange (ETDEWEB)

    Zankl, M. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz; Drexler, G. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz; Petoussi-Henss, N. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz; Saito, K. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan)

    1997-03-01

    This report presents a tabulation of organ and tissue equivalent dose as well as effective dose conversion coefficients, normalised to air kerma free in air, for occupational exposures and environmental exposures of the public to external photon radiation. For occupational exposures, whole-body irradiation with idealised geometries, i.e. broad parallel beams and fully isotropic radiation incidence, is considered. The directions of incidence for the parallel beams are anterior-posterior, posterior-anterior, left lateral, right lateral and a full 360 rotation around the body`s longitudinal axis. The influence of beam divergence on the body doses is also considered as well as the dependence of effective dose on the angle of radiation incidence. Regarding exposure of the public to environmental sources, three source geometries are considered: exposure from a radioactive cloud, from ground contamination and from the natural radionuclides distributed homogeneously in the ground. The precise angular and energy distributions of the gamma rays incident on the human body were taken into account. The organ dose conversion coefficients given in this catalogue were calculated using a Monte Carlo code simulating the photon transport in mathematical models of an adult male and an adult female, respectively. Conversion coefficients are given for the equivalent dose of 23 organs and tissues as well as for effective dose and the equivalent dose of the so-called `remainder`. The organ equivalent dose conversion coefficients are given separately for the adult male and female models and - as arithmetic mean of the conversion coefficients of both - for an average adult. Fitted data of the coefficients are presented in tables; the primary raw data as resulting from the Monte Carlo calculation are shown in figures together with the fitted data. (orig.)

  9. The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Pt. 7. Organ doses due to parallel and environmental exposure geometries

    International Nuclear Information System (INIS)

    Zankl, M.

    1997-03-01

    This report presents a tabulation of organ and tissue equivalent dose as well as effective dose conversion coefficients, normalised to air kerma free in air, for occupational exposures and environmental exposures of the public to external photon radiation. For occupational exposures, whole-body irradiation with idealised geometries, i.e. broad parallel beams and fully isotropic radiation incidence, is considered. The directions of incidence for the parallel beams are anterior-posterior, posterior-anterior, left lateral, right lateral and a full 360 rotation around the body's longitudinal axis. The influence of beam divergence on the body doses is also considered as well as the dependence of effective dose on the angle of radiation incidence. Regarding exposure of the public to environmental sources, three source geometries are considered: exposure from a radioactive cloud, from ground contamination and from the natural radionuclides distributed homogeneously in the ground. The precise angular and energy distributions of the gamma rays incident on the human body were taken into account. The organ dose conversion coefficients given in this catalogue were calculated using a Monte Carlo code simulating the photon transport in mathematical models of an adult male and an adult female, respectively. Conversion coefficients are given for the equivalent dose of 23 organs and tissues as well as for effective dose and the equivalent dose of the so-called 'remainder'. The organ equivalent dose conversion coefficients are given separately for the adult male and female models and - as arithmetic mean of the conversion coefficients of both - for an average adult. Fitted data of the coefficients are presented in tables; the primary raw data as resulting from the Monte Carlo calculation are shown in figures together with the fitted data. (orig.)

  10. Single and 30 fraction tumor control doses correlate in xenografted tumor models: implications for predictive assays

    International Nuclear Information System (INIS)

    Gerweck, Leo E.; Dubois, Willum; Baumann, Michael; Suit, Herman D.

    1995-01-01

    Purpose/Objective: In a previous publication we reported that laboratory assays of tumor clonogen number, in combination with intrinsic radiosensitivity measured in-vitro, accurately predicted the rank-order of single fraction 50% tumor control doses, in six rodent and xenografted human tumors. In these studies, tumor hypoxia influenced the absolute value of the tumor control doses across tumor types, but not their rank-order. In the present study we hypothesize that determinants of the single fraction tumor control dose, may also strongly influence the fractionaled tumor control doses, and that knowledge of tumor clonogen number and their sensitivity to fractionated irradiation, may be useful for predicting the relative sensitivity of tumors treated by conventional fractionated irradiation. Methods/Materials: Five tumors of human origin were used for these studies. Special care was taken to ensure that all tumor control dose assays were performed over the same time frame, i.e., in-vitro cells of a similar passage were used to initiate tumor sources which were expanded and used in the 3rd or 4th generation. Thirty fraction tumor control doses were performed in air breathing mice, under normal blood flow conditions (two fractions/day). The results of these studies have been previously published. For studies under uniformly (clamp) hypoxic conditions, tumors arising from the same transplantation were randomized into single or fractionated dose protocols. For estimation of the fractionated TCD50 under hypoxic conditions, tumors were exposed to six 5.4 Gy fractions (∼ 2 Gy equivalent under air), followed by graded 'top-up' dose irradiation for determination of the TCD50; the time interval between doses was 6-9 hours. The single dose equivalent of the six 5.4 Gy doses was used to calculate an extrapolated 30 fraction hypoxic TCD50. Results: Fractionation substantially increased the dose required for tumor control in 4 of the 5 tumors investigated. For these 4 tumors

  11. Comparison of single-dose and multiple-dose antibiotics for lower urinary tract infection in pregnancy.

    Science.gov (United States)

    Usta, Taner A; Dogan, Ozgur; Ates, Ugur; Yucel, Burak; Onar, Zehra; Kaya, Erdal

    2011-09-01

    To compare the efficacy of fosfomycin trometamol, cefuroxime axetil, and amoxicillin clavulanate antibiotics, and to assess the difference in patient compliance, in the treatment of urinary tract infections during pregnancy. Between September 2007 and May 2008, 90 out of 324 pregnant women with complaints of lower urinary tract infection, who were followed at the outpatient clinic or referred to the emergency department of Vakif Gureba Education and Research Hospital, were enrolled in a prospective study. Patients were randomized into 3 equal groups for treatment with single-dose fosfomycin trometamol, or 5-day courses of amoxicillin clavulanate or cefuroxime axetil. After follow-up, study data were obtained for 28, 27, and 29 patients, respectively. The treatment groups did not differ significantly in terms of demographics, clinical success rate, microbiological cure rate, or adverse effects. Significantly higher drug compliance was observed in the fosfomycin trometamol group than in the other 2 groups (PUTI as the standard course of treatment with amoxicillin clavulanate or cefuroxime axetil. Fosfomycin trometamol may be a preferable treatment for UTI because of its simpler use and better rates of compliance. Copyright © 2011 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Single-layer group IV-V and group V-IV-III-VI semiconductors: Structural stability, electronic structures, optical properties, and photocatalysis

    Science.gov (United States)

    Lin, Jia-He; Zhang, Hong; Cheng, Xin-Lu; Miyamoto, Yoshiyuki

    2017-07-01

    Recently, single-layer group III monochalcogenides have attracted both theoretical and experimental interest at their potential applications in photonic devices, electronic devices, and solar energy conversion. Excited by this, we theoretically design two kinds of highly stable single-layer group IV-V (IV =Si ,Ge , and Sn; V =N and P) and group V-IV-III-VI (IV =Si ,Ge , and Sn; V =N and P; III =Al ,Ga , and In; VI =O and S) compounds with the same structures with single-layer group III monochalcogenides via first-principles simulations. By using accurate hybrid functional and quasiparticle methods, we show the single-layer group IV-V and group V-IV-III-VI are indirect bandgap semiconductors with their bandgaps and band edge positions conforming to the criteria of photocatalysts for water splitting. By applying a biaxial strain on single-layer group IV-V, single-layer group IV nitrides show a potential on mechanical sensors due to their bandgaps showing an almost linear response for strain. Furthermore, our calculations show that both single-layer group IV-V and group V-IV-III-VI have absorption from the visible light region to far-ultraviolet region, especially for single-layer SiN-AlO and SnN-InO, which have strong absorption in the visible light region, resulting in excellent potential for solar energy conversion and visible light photocatalytic water splitting. Our research provides valuable insight for finding more potential functional two-dimensional semiconductors applied in optoelectronics, solar energy conversion, and photocatalytic water splitting.

  13. Pharmacokinetics of voriconazole after oral administration of single and multiple doses in African grey parrots (Psittacus erithacus timneh).

    Science.gov (United States)

    Flammer, Keven; Nettifee Osborne, Julie A; Webb, Donna J; Foster, Laura E; Dillard, Stacy L; Davis, Jennifer L

    2008-01-01

    To determine the pharmacokinetics and safety of orally administered voriconazole in African grey parrots. 20 clinically normal Timneh African grey parrots (Psittacus erithacus timneh). In single-dose trials, 12 parrots were each administered 6, 12, and 18 mg of voriconazole/kg orally and plasma concentrations of voriconazole were determined via high-pressure liquid chromatography. In a multiple-dose trial, voriconazole (18 mg/kg) was administered orally to 6 birds every 12 hours for 9 days; a control group (2 birds) received tap water. Treatment effects were assessed via observation, clinicopathologic analyses (3 assessments), and measurement of trough plasma voriconazole concentrations (2 assessments). Voriconazole's elimination half-life was short (1.1 to 1.6 hours). Higher doses resulted in disproportional increases in the maximum plasma voriconazole concentration and area under the curve. Trough plasma voriconazole concentrations achieved in the multiple-dose trial were lower than those achieved after administration of single doses. Polyuria (the only adverse treatment effect) developed in treated and control birds but was more severe in the treatment group. In African grey parrots, voriconazole has dose-dependent pharmacokinetics and may induce its own metabolism. Oral administration of 12 to 18 mg of voriconazole/kg twice daily is a rational starting dose for treatment of African grey parrots infected with Aspergillus or other fungal organisms that have a minimal inhibitory concentration for voriconazole treatment. Safety and efficacy of various voriconazole treatment regimens in this species require investigation.

  14. Exploiting Symmetry on Parallel Architectures.

    Science.gov (United States)

    Stiller, Lewis Benjamin

    1995-01-01

    This thesis describes techniques for the design of parallel programs that solve well-structured problems with inherent symmetry. Part I demonstrates the reduction of such problems to generalized matrix multiplication by a group-equivariant matrix. Fast techniques for this multiplication are described, including factorization, orbit decomposition, and Fourier transforms over finite groups. Our algorithms entail interaction between two symmetry groups: one arising at the software level from the problem's symmetry and the other arising at the hardware level from the processors' communication network. Part II illustrates the applicability of our symmetry -exploitation techniques by presenting a series of case studies of the design and implementation of parallel programs. First, a parallel program that solves chess endgames by factorization of an associated dihedral group-equivariant matrix is described. This code runs faster than previous serial programs, and discovered it a number of results. Second, parallel algorithms for Fourier transforms for finite groups are developed, and preliminary parallel implementations for group transforms of dihedral and of symmetric groups are described. Applications in learning, vision, pattern recognition, and statistics are proposed. Third, parallel implementations solving several computational science problems are described, including the direct n-body problem, convolutions arising from molecular biology, and some communication primitives such as broadcast and reduce. Some of our implementations ran orders of magnitude faster than previous techniques, and were used in the investigation of various physical phenomena.

  15. Clinicopathological study of nondiabetic renal disease in type 2 diabetic patients: A single center experience from India

    Directory of Open Access Journals (Sweden)

    Kamal V Kanodia

    2017-01-01

    Full Text Available Diabetic nephropathy (DN is a major complication of diabetes mellitus (DM, leading to chronic kidney disease/end-stage renal disease. Wide spectrum of nondiabetic renal diseases (NDRD is reported in type-2 diabetes (type-2 DM. We carried out this single-center study to find clinical, laboratory, and histological features of NDRD in type-2 DM patients and to assess the prevalence of NDRD in India. A single-center retrospective study which included analysis of renal biopsies from patients with type-2 DM, performed between January 2008 and September 2016. Biopsy findings were categorized into three groups, Group-I (isolated NDRD; Group-II (NDRD superimposed on underlying DN; and Group-III (isolated DN. Out of 152 diabetic patients (111 males and 41 females, 35 (23.03% patients were of Group-I (isolated NDRD, 35 (23.03% of Group-II (NDRD superimposed on underlying DN, and 82 (53.95% of Group-III (isolated DN. The mean age (in years was 55.08 ± 10.71, 55.65 ± 8.71, and 54.45 ± 9.01 respectively in Group-I, II, and III. Nephrotic syndrome (NS was the most common clinical presentation in all groups. Duration of DM was significantly shorter in Group-I than in Group-II. Diabetic retinopathy was absent in Group-I. Proteinuria was more in Group-III than Group-I. Low serum C3 and/or C4 levels was observed in five (14.29% cases of Group-I and Group-II each and two (2.43% cases of Group-III. Nearly, 70 (46.05% patients were found to have NDRD either in isolated form or as combined lesions. The most common histological types of NDRD were acute tubulointerstitial nephritis (38.57% followed by benign nephrosclerosis (15.72%, membranous nephropathy (10%, IgA nephropathy (7.14%, and membranoproliferative glomerulonephritis (7.14%. The incidence of NDRD (with/without DN in type-2 DM is very high. Shorter duration of diabetes, hematuria, absence of retinopathy, low serum complement levels, and nephrotic range proteinuria are predictors of NDRD.

  16. Risk group dependence of dose-response for biopsy outcome after three-dimensional conformal radiation therapy of prostate cancer

    International Nuclear Information System (INIS)

    Levegruen, Sabine; Jackson, Andrew; Zelefsky, Michael J.; Venkatraman, Ennapadam S.; Skwarchuk, Mark W.; Schlegel, Wolfgang; Fuks, Zvi; Leibel, Steven A.; Ling, C. Clifton

    2002-01-01

    Background and purpose: We fit phenomenological tumor control probability (TCP) models to biopsy outcome after three-dimensional conformal radiation therapy (3D-CRT) of prostate cancer patients to quantify the local dose-response of prostate cancer. Materials and methods: We analyzed the outcome after photon beam 3D-CRT of 103 patients with stage T1c-T3 prostate cancer treated at Memorial Sloan-Kettering Cancer Center (MSKCC) (prescribed target doses between 64.8 and 81 Gy) who had a prostate biopsy performed ≥2.5 years after end of treatment. A univariate logistic regression model based on D mean (mean dose in the planning target volume of each patient) was fit to the whole data set and separately to subgroups characterized by low and high values of tumor-related prognostic factors T-stage ( 6), and pre-treatment prostate-specific antigen (PSA) (≤10 ng/ml vs. >10 ng/ml). In addition, we evaluated five different classifications of the patients into three risk groups, based on all possible combinations of two or three prognostic factors, and fit bivariate logistic regression models with D mean and the risk group category to all patients. Dose-response curves were characterized by TCD 50 , the dose to control 50% of the tumors, and γ 50 , the normalized slope of the dose-response curve at TCD 50 . Results: D mean correlates significantly with biopsy outcome in all patient subgroups and larger values of TCD 50 are observed for patients with unfavorable compared to favorable prognostic factors. For example, TCD 50 for high T-stage patients is 7 Gy higher than for low T-stage patients. For all evaluated risk group definitions, D mean and the risk group category are independent predictors of biopsy outcome in bivariate analysis. The fit values of TCD 50 show a clear separation of 9-10.6 Gy between low and high risk patients. The corresponding dose-response curves are steeper (γ 50 =3.4-5.2) than those obtained when all patients are analyzed together (γ 50 =2

  17. A phase I, randomized, single-dose study evaluating the pharmacokinetic equivalence of biosimilar ABP 215 and bevacizumab in healthy adult men.

    Science.gov (United States)

    Markus, Richard; Chow, Vincent; Pan, Zhiying; Hanes, Vladimir

    2017-10-01

    This study compared the pharmacokinetic (PK) profiles of the proposed biosimilar ABP 215 with bevacizumab in healthy males. In this randomized, single-blind, single-dose, three-arm, parallel-group study, healthy subjects were randomized to receive ABP 215 (n = 68), bevacizumab (US) (n = 67), or bevacizumab (EU) (n = 67) 3 mg/kg intravenously. Primary endpoints were area under the serum concentration-time curve from time 0 extrapolated to infinity (AUC inf ) and the maximum observed concentration (C max ). Secondary endpoints included safety and immunogenicity. AUC inf and C max were similar across the three groups. Geometric means ratio (GMR) for C max and AUC inf , respectively, was 0.98 and 0.99 for ABP 215 versus bevacizumab (US); 1.03 and 0.96 for ABP 215 versus bevacizumab (EU); and 1.05 and 0.97 for bevacizumab (US) versus bevacizumab (EU). The 90% confidence intervals for the GMRs of AUC inf and C max were within the prespecified standard PK bioequivalence criteria of 0.80 to 1.25. The incidence of adverse events (AEs) was 47.1, 32.8, and 61.2% in the ABP 215, bevacizumab (US) and bevacizumab (EU) groups, respectively. When analyzed by investigational site, the incidence and severity of AEs were comparable in the ABP 215 and bevacizumab groups. There were no AEs leading to study discontinuation. No binding or neutralizing anti-drug anti-bodies was detected. This study demonstrated the PK similarity of ABP 215 to both bevacizumab (US) and bevacizumab (EU), and of bevacizumab (US) to bevacizumab (EU). Safety and tolerability were comparable between treatments and no subject developed binding or neutralizing anti-drug anti-bodies.

  18. Evaluation of the Pharmacokinetics of Single- and Multiple-dose Buprenorphine Buccal Film in Healthy Volunteers.

    Science.gov (United States)

    Bai, Stephen A; Xiang, Qinfang; Finn, Andrew

    2016-02-01

    Buprenorphine, a partial μ-receptor agonist, is approved for the management of moderate to severe pain, but it has low oral bioavailability. Two open-label studies were performed to determine the pharmacokinetic profile of buprenorphine from buccal film formulations of buprenorphine. Both studies enrolled healthy volunteers, aged 18 to 55 years, who received concurrent oral naltrexone to reduce adverse events (AEs); subjects with a history or evidence of substance abuse or current use of any product affecting cytochrome P450 3A4 activity were excluded. The first study (n = 25) was a 5-period crossover trial with 4 single doses (75 and 300 and 300 and 1200 μg) of 2 formulations (F14 and F24) of buccal buprenorphine (BBUP) and a 300-μg intravenous dose of buprenorphine with a 7-day washout between periods. In the second study, each subject (n = 10) received 6 doses of 4 BBUP strengths (60, 120, 180, and 240 μg BID) in a dose-escalation design. Plasma concentrations of buprenorphine and norbuprenorphine were assayed, and pharmacokinetics were summarized with descriptive statistics and analyzed by using a linear mixed effects model (single-dose study). AEs were recorded. In the single-dose study, the 2 formulations exhibited comparable bioavailability of 46% to 51% that was independent of dose, with a single buprenorphine peak concentration from each BBUP dose occurring at 2.5 to 3 hours. The mean buprenorphine Cmax across the doses ranged from 0.17 ng/mL for the 75-µg dose to 1.43 ng/mL for the 1200-µg dose. AUC0-∞, AUC0-last, and Cmax were proportional to the dose of BBUP administered. Cmax of norbuprenorphine after BBUP administration was approximately one tenth that of buprenorphine Cmax. In the multiple-dose study, steady state was reached within 3 days of BID dosing. There was a linear increase in exposure across the dose range from 60 to 240 μg BID. Treatment-emergent AEs in both studies were consistent with those reported with opiate administration to

  19. Single-Dose Azithromycin for the Treatment of Haemophilus ducreyi Skin Ulcers in Papua New Guinea.

    Science.gov (United States)

    González-Beiras, Camila; Kapa, August; Vall-Mayans, Marti; Paru, Raymond; Gavilán, Sergi; Houinei, Wendy; Bieb, Sibauk; Sanz, Sergi; Martins, Rosario; Mitjà, Oriol

    2017-11-29

    Haemophilus ducreyi (HD) and Treponema pallidum subspecies pertenue (TP) are major causative agents of cutaneous ulcer (CU) in the tropics. Azithromycin is recommended to treat sexually transmitted HD infections and has good in vitro activity against HD strains from both genital and skin ulcers. We investigated the efficacy of oral single-dose azithromycin on HD-CU. We conducted a community-based cohort study in Lihir Island, Papua New Guinea, from October 2014 through May 2016. Consenting patients with skin ulcers >1 cm in diameter were eligible for this study and had collected a lesional swab for polymerase chain reaction (PCR). All participants were treated with single-dose azithromycin (30 mg/kg) and were followed up for assessment of clinical resolution. We retrospectively classified patients according to PCR results into HD, TP, and PCR-negative groups. The primary endpoint was healing rates of HD-CU at 14 days after treatment. We obtained full outcome data from 246 patients; 131 (53.3%) were HD PCR positive, 37 (15.0%) were TP positive, and 78 (31.7%) were negative for all tests. Healing rates were 88.5% (95% confidence interval [CI], .82-.93) in the HD group, 78.4% [95% CI, .63-.89] in the TP group, and 74.4% (95% CI, .64-.83) in the PCR-negative group. If we included the participants with improved ulcers, the healing rates increased to 94.7%, 97.3%, and 89.7% respectively. HD cases classified as not healed all converted to HD-negative PCR. Based upon clinical resolution and PCR conversion to HD negative, a single oral dose of azithromycin is efficacious for the treatment of HD-CU. These results have implications for the treatment of individual patients and for the use of antibiotics in public health strategies to control CU in the tropics. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  20. A Green's function method for two-dimensional reactive solute transport in a parallel fracture-matrix system

    Science.gov (United States)

    Chen, Kewei; Zhan, Hongbin

    2018-06-01

    The reactive solute transport in a single fracture bounded by upper and lower matrixes is a classical problem that captures the dominant factors affecting transport behavior beyond pore scale. A parallel fracture-matrix system which considers the interaction among multiple paralleled fractures is an extension to a single fracture-matrix system. The existing analytical or semi-analytical solution for solute transport in a parallel fracture-matrix simplifies the problem to various degrees, such as neglecting the transverse dispersion in the fracture and/or the longitudinal diffusion in the matrix. The difficulty of solving the full two-dimensional (2-D) problem lies in the calculation of the mass exchange between the fracture and matrix. In this study, we propose an innovative Green's function approach to address the 2-D reactive solute transport in a parallel fracture-matrix system. The flux at the interface is calculated numerically. It is found that the transverse dispersion in the fracture can be safely neglected due to the small scale of fracture aperture. However, neglecting the longitudinal matrix diffusion would overestimate the concentration profile near the solute entrance face and underestimate the concentration profile at the far side. The error caused by neglecting the longitudinal matrix diffusion decreases with increasing Peclet number. The longitudinal matrix diffusion does not have obvious influence on the concentration profile in long-term. The developed model is applied to a non-aqueous-phase-liquid (DNAPL) contamination field case in New Haven Arkose of Connecticut in USA to estimate the Trichloroethylene (TCE) behavior over 40 years. The ratio of TCE mass stored in the matrix and the injected TCE mass increases above 90% in less than 10 years.

  1. Pharmacokinetics of lansoprazole and its main metabolites after single and multiple intravenous doses in healthy Chinese subjects.

    Science.gov (United States)

    Zhang, Dan; Zhang, Yanan; Liu, Man; Wang, Xiaolin; Yang, Man; Han, Jing; Liu, Huichen

    2013-09-01

    The aim of the study was to evaluate and compare the pharmacokinetics of lansoprazole (LPZ) and its main metabolites, 5'-hydroxy lansoprazole (HLPZ) and lansoprazole sulfone (LPZS), after single and multiple intravenous (i.v.) doses of LPZ in healthy Chinese subjects. Twelve subjects (six males and six females) were given a single dose of LPZ by i.v. infusion on day 1, and multiple doses from day 2 to day 6. Blood samples were collected at designated time points for analysis of plasma concentrations of LPZ, HLPZ and LPZS by an LC-MS/MS method. LPZ was generally well tolerated in healthy Chinese subjects. After single and multiple i.v. doses of 30 mg LPZ, the C max values of LPZ, HLPZ and LPZS were 1490 ± 290 and 1450 ± 280, 175 ± 71 and 154 ± 56, and 51.3 ± 82.9 and 74.1 ± 158.7 ng/mL, with the AUC0-t values 3280 ± 2550 and 4260 ± 3880, 381 ± 128 and 389 ± 111, and 389 ± 1204 and 700 ± 2255 ng h/mL, respectively. The t 1/2 and CL values of LPZ after single and multiple i.v. doses were 1.48 ± 1.03 and 2.19 ± 1.03 h, and 11.67 ± 4.49 and 9.56 ± 4.08 L/h, respectively. Compared with the pharmacokinetics of LPZ after a single dose, t 1/2 increased markedly, CL decreased significantly and AUC increased by over 20 % after multiple doses. The results indicated that there was drug accumulation of LPZ after multiple i.v. doses, and there was no gender-related difference in pharmacokinetics of LPZ and its two metabolites.

  2. Iron concentration in breast milk normalised within one week of a single high-dose infusion of iron isomaltoside in randomised controlled trial

    DEFF Research Database (Denmark)

    Holm, Charlotte; Thomsen, Lars Lykke; Nørgaard, Astrid

    2017-01-01

    AIM: We compared the iron concentration in breast milk after a single high-dose of intravenous iron isomaltoside or daily oral iron for postpartum haemorrhage. METHODS: In this randomised controlled trial, the women were allocated a single dose of intravenous 1,200mg iron isomaltoside or oral iron...... deviation) iron concentration in breast milk in the intravenous and oral groups were 0.72 ± 0.27 mg/L and 0.40 ± 0.18 mg/L at three days (p birth. CONCLUSION: A single high...

  3. Efficacy and safety of low-dose valganciclovir for prevention of cytomegalovirus disease in renal transplant recipients: a single-center, retrospective analysis.

    Science.gov (United States)

    Gabardi, Steven; Magee, Colm C; Baroletti, Steven A; Powelson, John A; Cina, Jennifer L; Chandraker, Anil K

    2004-10-01

    To evaluate the safety and efficacy of valganciclovir 450 mg/day for 6 months for cytomegalovirus (CMV) prophylaxis in renal transplant recipients. Single-center, retrospective analysis. Urban, academic medical center. Fifty-eight patients who received de novo renal transplants from August 1, 2001-November 21, 2002. Valganciclovir 450 mg/day was administered to all renal transplant recipients at risk for CMV disease. Therapy was begun postoperatively and was dose adjusted to renal function. Data collected from renal transplant recipients were demographics, immunosuppressive and antiviral drug therapy, and occurrence of CMV disease, acute rejection, allograft loss, and hematologic adverse events. Donor (D)/recipient (R) CMV serostatus was 37.9% D+/R+, 29.3% D-/R+, 17.3% D+/R-, and 15.5% D-/R-. Antithymocyte globulin (ATG) was administered to 62.1% of patients. Most of the transplant recipients received triple immunosuppression as maintenance therapy. Median follow-up was 20 months. The frequency of CMV disease was 1.7% within 6 months after transplantation and 5.2% at any point after transplantation. All patients who developed CMV disease were D+/R- and had received ATG. Leukopenia and thrombocytopenia associated with valganciclovir were seen in 28% and 24% of patients, respectively. One patient developed acute cellular rejection. No graft losses or deaths occurred. Early discontinuation of valganciclovir occurred in 20% of patients secondary to severe, persistent leukopenia, thrombocytopenia, and/or diarrhea. None of these patients developed CMV disease. A high rate of CMV disease was noted among the D+/R- population. Administration of ATG as an induction agent also increased the frequency of CMV disease. Despite the low dosage of valganciclovir, hematologic adverse events were common. However, valganciclovir, administered at 450 mg/day for 6 months, was effective and relatively safe for prophylaxis of CMV disease in renal transplant recipients.

  4. A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

    Energy Technology Data Exchange (ETDEWEB)

    Ballester, Facundo, E-mail: Facundo.Ballester@uv.es [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Carlsson Tedgren, Åsa [Department of Medical and Health Sciences (IMH), Radiation Physics, Faculty of Health Sciences, Linköping University, Linköping SE-581 85, Sweden and Department of Medical Physics, Karolinska University Hospital, Stockholm SE-171 76 (Sweden); Granero, Domingo [Department of Radiation Physics, ERESA, Hospital General Universitario, Valencia E-46014 (Spain); Haworth, Annette [Department of Physical Sciences, Peter MacCallum Cancer Centre and Royal Melbourne Institute of Technology, Melbourne, Victoria 3000 (Australia); Mourtada, Firas [Department of Radiation Oncology, Helen F. Graham Cancer Center, Christiana Care Health System, Newark, Delaware 19713 (United States); Fonseca, Gabriel Paiva [Instituto de Pesquisas Energéticas e Nucleares – IPEN-CNEN/SP, São Paulo 05508-000, Brazil and Department of Radiation Oncology (MAASTRO), GROW, School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Zourari, Kyveli; Papagiannis, Panagiotis [Medical Physics Laboratory, Medical School, University of Athens, 75 MikrasAsias, Athens 115 27 (Greece); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Siebert, Frank-André [Clinic of Radiotherapy, University Hospital of Schleswig-Holstein, Campus Kiel, Kiel 24105 (Germany); Sloboda, Ron S. [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada); and others

    2015-06-15

    Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by

  5. Coupling a single nitrogen-vacancy center with a superconducting qubit via the electro-optic effect

    Science.gov (United States)

    Li, Chang-Hao; Li, Peng-Bo

    2018-05-01

    We propose an efficient scheme for transferring quantum states and generating entangled states between two qubits of different nature. The hybrid system consists of a single nitrogen-vacancy (NV) center and a superconducting (SC) qubit, which couple to an optical cavity and a microwave resonator, respectively. Meanwhile, the optical cavity and the microwave resonator are coupled via the electro-optic effect. By adjusting the relative parameters, we can achieve high-fidelity quantum state transfer as well as highly entangled states between the NV center and the SC qubit. This protocol is within the reach of currently available techniques, and may provide interesting applications in quantum communication and computation with single NV centers and SC qubits.

  6. SU-F-SPS-09: Parallel MC Kernel Calculations for VMAT Plan Improvement

    International Nuclear Information System (INIS)

    Chamberlain, S; French, S; Nazareth, D

    2016-01-01

    Purpose: Adding kernels (small perturbations in leaf positions) to the existing apertures of VMAT control points may improve plan quality. We investigate the calculation of kernel doses using a parallelized Monte Carlo (MC) method. Methods: A clinical prostate VMAT DICOM plan was exported from Eclipse. An arbitrary control point and leaf were chosen, and a modified MLC file was created, corresponding to the leaf position offset by 0.5cm. The additional dose produced by this 0.5 cm × 0.5 cm kernel was calculated using the DOSXYZnrc component module of BEAMnrc. A range of particle history counts were run (varying from 3 × 10"6 to 3 × 10"7); each job was split among 1, 10, or 100 parallel processes. A particle count of 3 × 10"6 was established as the lower range because it provided the minimal accuracy level. Results: As expected, an increase in particle counts linearly increases run time. For the lowest particle count, the time varied from 30 hours for the single-processor run, to 0.30 hours for the 100-processor run. Conclusion: Parallel processing of MC calculations in the EGS framework significantly decreases time necessary for each kernel dose calculation. Particle counts lower than 1 × 10"6 have too large of an error to output accurate dose for a Monte Carlo kernel calculation. Future work will investigate increasing the number of parallel processes and optimizing run times for multiple kernel calculations.

  7. Stratified steady and unsteady two-phase flows between two parallel plates

    International Nuclear Information System (INIS)

    Sim, Woo Gun

    2006-01-01

    To understand fluid dynamic forces acting on a structure subjected to two-phase flow, it is essential to get detailed information about the characteristics of two-phase flow. Stratified steady and unsteady two-phase flows between two parallel plates have been studied to investigate the general characteristics of the flow related to flow-induced vibration. Based on the spectral collocation method, a numerical approach has been developed for the unsteady two-phase flow. The method is validated by comparing numerical result to analytical one given for a simple harmonic two-phase flow. The flow parameters for the steady two-phase flow, such as void fraction and two-phase frictional multiplier, are evaluated. The dynamic characteristics of the unsteady two-phase flow, including the void fraction effect on the complex unsteady pressure, are illustrated

  8. Canal transportation and centering ability of protaper and self-adjusting file system in long oval canals: An ex-vivo cone-beam computed tomography analysis.

    Science.gov (United States)

    Shah, Dipali Yogesh; Wadekar, Swati Ishwara; Dadpe, Ashwini Manish; Jadhav, Ganesh Ranganath; Choudhary, Lalit Jayant; Kalra, Dheeraj Deepak

    2017-01-01

    The purpose of this study was to compare and evaluate the shaping ability of ProTaper (PT) and Self-Adjusting File (SAF) system using cone-beam computed tomography (CBCT) to assess their performance in oval-shaped root canals. Sixty-two mandibular premolars with single oval canals were divided into two experimental groups ( n = 31) according to the systems used: Group I - PT and Group II - SAF. Canals were evaluated before and after instrumentation using CBCT to assess centering ratio and canal transportation at three levels. Data were statistically analyzed using one-way analysis of variance, post hoc Tukey's test, and t -test. The SAF showed better centering ability and lesser canal transportation than the PT only in the buccolingual plane at 6 and 9 mm levels. The shaping ability of the PT was best in the apical third in both the planes. The SAF had statistically significant better centering and lesser canal transportation in the buccolingual as compared to the mesiodistal plane at the middle and coronal levels. The SAF produced significantly less transportation and remained centered than the PT at the middle and coronal levels in the buccolingual plane of oval canals. In the mesiodistal plane, the performance of both the systems was parallel.

  9. Acoustic neuromas: single dose vs fractionated therapy

    International Nuclear Information System (INIS)

    Fuss, M.; Debus, J.; Lohr, F.; Engenhart-Cabillic, R.; Wannenmacher, M.

    1997-01-01

    Purpose: Radiosurgical treatment (RS) of acoustic neuromas is a well established treatment. However, few data are available concerning conformal fractionated radiotherapy (FT) of this tumor entity. We evaluated treatment outcome and toxicity for both treatment modalities in 41 patients treated at our institution between 1984 and 1997. Material and Methods: All treatments were performed using a specially adapted linear accelerator and circular collimators for convergent beam RS or multi-leaf collimators (leaf thickness 1 or 3mm) for multi-field RS or fractionated treatment. 22 patients (7 male, 15 female, median age 60 years, range 20-83 years) were treated radiosurgically with single doses between 7 and 28 Gray (median 15 Gy) prescribed to the 80% isodose line. Tumor volumes ranged from 0.7 to 10.5 ccm with a median volume of 3.4 ccm. The median number of isocenters was 2 (1-4 isocenters). One patient was treated by a multi-field technique (14 isocentric irregularly shaped noncoplanar fields). 19 patients (5 male, 14 female, median age 55 years, range 20-81 years) were treated with stereotactic conformal radiotherapy. Median dose was 60 Gray with a median daily fraction size of 2 Gy and a median of 3 (1-4) irregularly shaped isocentric fields. Tumor volumes ranged from 0.7 to 32.4 ccm (median 15 ccm). Median follow-up was 30 months (7-149 months) for radiosurgical and 30 months (2-88 months) for fractionated treatment. Seven patients who underwent fractionated treatment had previously undergone neurosurgical resection on the contralateral side. One had undergone radiosurgery on the opposite side before. Results: All tumors were locally controlled. A volume reduction of more than 20% was seen in 16% after RS and 18% following FT. Typical posttherapeutic central reduction of contrast media enhancement was found in 73% following RS after a median of 8 (3-12) months and in 63% following FT after a median of 6 (1-12) months. Temporary brainstem edema was diagnosed in 4

  10. Dose optimisation in single plane interstitial brachytherapy

    DEFF Research Database (Denmark)

    Tanderup, Kari; Hellebust, Taran Paulsen; Honoré, Henriette Benedicte

    2006-01-01

    patients,       treated for recurrent rectal and cervical cancer, flexible catheters were       sutured intra-operatively to the tumour bed in areas with compromised       surgical margin. Both non-optimised, geometrically and graphically       optimised CT -based dose plans were made. The overdose index...... on the       regularity of the implant, such that the benefit of optimisation was       larger for irregular implants. OI and HI correlated strongly with target       volume limiting the usability of these parameters for comparison of dose       plans between patients. CONCLUSIONS: Dwell time optimisation significantly......BACKGROUND AND PURPOSE: Brachytherapy dose distributions can be optimised       by modulation of source dwell times. In this study dose optimisation in       single planar interstitial implants was evaluated in order to quantify the       potential benefit in patients. MATERIAL AND METHODS: In 14...

  11. Sustained Antibody Responses 6 Years Following 1, 2, or 3 Doses of Quadrivalent Human Papillomavirus (HPV) Vaccine in Adolescent Fijian Girls, and Subsequent Responses to a Single Dose of Bivalent HPV Vaccine: A Prospective Cohort Study.

    Science.gov (United States)

    Toh, Zheng Quan; Russell, Fiona M; Reyburn, Rita; Fong, James; Tuivaga, Evelyn; Ratu, Tupou; Nguyen, Cattram D; Devi, Rachel; Kama, Mike; Matanitobua, Silivia; Tabrizi, Sepehr N; Garland, Suzanne M; Sinha, Rohit; Frazer, Ian; Tikoduadua, Lisi; Kado, Joseph; Rafai, Eric; Mulholland, Edward K; Licciardi, Paul V

    2017-04-01

    The duration of antibody response following reduced human papillomavirus (HPV) vaccine doses has not been determined. We compared the antibody responses in girls previously vaccinated with zero, 1, 2, or 3 doses of quadrivalent HPV vaccine (4vHPV; Gardasil, Merck) 6 years previously. A prospective cohort study was undertaken in 200 Fijian girls 15-19 years of age. Approximately equal numbers of girls from 2 main ethnic groups (Fijians of Indian descent [FID] and Indigenous Fijians [iTaukei]) in Fiji were recruited for each dosage groups. Blood was drawn before and 28 days following a single dose of bivalent HPV vaccine (2vHPV; Cervarix, GlaxoSmithKline). We measured neutralizing antibodies (NAb) against HPV-6, -11, -16, and -18 using the pseudovirion-based neutralization assay. After 6 years (before a dose of 2vHPV was given), the geometric mean NAb titers for all 4 HPV types were not statistically different between 2-dose (2D) and 3-dose (3D) recipients: HPV-6 (3D: 2216 [95% confidence interval {CI},1695-2896]; 2D: 1476 [95% CI, 1019-2137]; P = .07), HPV-11 (3D: 4431 [95% CI, 3396-5783]; 2D: 2951 [95% CI, 1984-4390]; P = .09), HPV-16 (3D: 3373 [95% CI, 2511-4530]; 2D: 3275 [95% CI, 2452-4373]; P = .89); HPV-18 (3D: 628 [95% CI: 445-888]; 2D: 606 [95% CI, 462-862]; P = .89), and were higher in FID than iTaukei girls. Although 1-dose recipients had significantly lower NAb titers than 2-/3-dose recipients, their NAb titers were 5- to 30-fold higher than unvaccinated girls. Post-2vHPV NAb titers against HPV-16 and -18 were not statistically different between girls who received 1, 2, or 3 doses of 4vHPV previously. Two doses of 4vHPV provide similar NAb titers as 3 doses for 6 years, although the clinical significance is unknown. A single dose of 4vHPV elicits antibodies that persisted for at least 6 years, and induced immune memory, suggesting possible protection against HPV vaccine types after a single dose of 4vHPV. © The Author 2016. Published by Oxford University

  12. Randomized Crossover Comparison of the Short-Term Efficacy and Safety of Single Half-Dose Silodosin and Tamsulosin Hydrochoride in Men With Lower Urinary Tract Symptoms Secondary to Benign Prostatic Hyperplasia.

    Science.gov (United States)

    Takeshita, Hideki; Moriyama, Shingo; Arai, Yoshiaki; Washino, Satoshi; Saito, Kimitoshi; Chiba, Koji; Horiuchi, Susumu; Noro, Akira

    2016-01-01

    To compare the efficacy and safety of single half-dose silodosin and single full-dose tamsulosin in Japanese men with lower urinary tract symptoms secondary to benign prostatic hyperplasia (LUTS/BPH). Japanese men aged ≥50 years with LUTS/BPH and an International Prostate Symptom Score (IPSS) of ≥8 were enrolled in the randomized crossover study and divided into silodosin-preceding (S-T) and tamsulosin-preceding (T-S) groups. The S-T group received 4 mg silodosin once daily for 4 weeks followed by 0.2 mg tamsulosin once daily for 4 weeks. The T-S group received the reverse treatment sequence. A washout period prior to drug crossover was not included. Subjective and objective efficacy parameters including IPSS, quality of life (QOL) index, uroflowmetry, and safety were compared between the two groups. Thirty of 34 men (S-T group n = 16; T-S group n = 14) completed the study. Both drugs significantly improved all IPSS items and QOL index in the first treatment period. Subjective improvement in nocturia by silodosin was observed in both the first and crossover treatment periods. Objective improvement in maximum flow rate by silodosin was only observed in the first treatment period. Adverse events occurred more frequently with silodosin than with tamsulosin; however, none of the adverse events required treatment discontinuation. Ejaculation disorders occurred in three participants (10%) and were associated with silodosin use. Single half-dose silodosin has a similar efficacy to full-dose tamsulosin in Japanese men with LUTS/BPH and thus, may represent an effective, safe, and affordable treatment option. © 2015 Wiley Publishing Asia Pty Ltd.

  13. Effects of Glide Path on the Centering Ability and Preparation Time of Two Reciprocating Instruments

    Science.gov (United States)

    Coelho, Marcelo Santos; Fontana, Carlos Eduardo; Kato, Augusto Shoji; de Martin, Alexandre Sigrist; da Silveira Bueno, Carlos Eduardo

    2016-01-01

    Introduction: The aim of this in vitro study was to evaluate the effects of establishing glide path on the centering ability and preparation time of two single-file reciprocating systems in mesial root canals of mandibular molars. Methods and Materials: Sixty extracted mandibular molars with curvatures of 25-39 degrees and separate foramina for the mesiobuccal and mesiolingual canals, were divided into four groups (n=15); WaveOne+glide path; WaveOne; Reciproc+glide path and Reciproc. Non-patent canals were excluded and only one canal in each tooth was instrumented. A manual glide path was established in first and third groups with #10, 15 and 20 hand K-files. Preparation was performed with reciprocating in-and-out motion, with a 3-4 mm amplitude and slight apical pressure. Initial and final radiographs were taken to analyze the amount of dentin removed in the instrumented canals. The radiographs were superimposed with an image editing software and examined to assess discrepancies at 3-, 6- and 9-mm distances from the apex. The Kruskal-Wallis test was used for statistical analysis. The level of significance was set at 0.05. Results: Preparation in groups without glide paths was swifter than the other groups (P=0.001). However, no difference was observed regarding centering ability. Conclusion: Establishing a glide path increased the total instrumentation time for preparing curved canals with WaveOne and Reciproc instruments. Glide path had no influence on the centering ability of these systems. PMID:26843875

  14. A quality improvement project to reduce the intraoperative use of single-dose fentanyl vials across multiple patients in a pediatric institution.

    Science.gov (United States)

    Buck, David; Subramanyam, Rajeev; Varughese, Anna

    2016-01-01

    The use of a single-dose vial across multiple patients presents a risk to sterility and is against CDC guidelines. We initiated a quality improvement (QI) project to reduce the intraoperative use of single-dose vials of fentanyl across multiple patients at Cincinnati Children's Hospital Medical Center (CCHMC). The initial step of the improvement project was the development of a Key Driver Diagram. The diagram has the SMART aim of the project, key drivers inherent to the process we are trying to improve, and specific interventions targeting the key drivers. The number of patients each week receiving an IV dose of fentanyl, from a vial previously accessed for another patient was tracked in a high turnover operating room (OR). The improvement model used was based on the concept of building Plan-Do-Study-Act (PDSA) cycles. Tests of change included provider education, provision of an increased number of fentanyl vials, alternate wasting processes, and provision of single-use fentanyl syringes by the pharmacy. Prior to initiation of this project, it was common for a single fentanyl vial to be accessed for multiple patients. Our data showed an average percentage of failures of just over 50%. During the end of the project, after 7 months, the mean percentage failures had dropped to 5%. Preparation of 20 mcg single-use fentanyl syringes by pharmacy, combined with education of providers on appropriate use, was successful in reducing failures to below our goal of 25%. Appropriately sized fentanyl syringes prepared by pharmacy, education on correct use of single-dose vials, and reminders in the OR, reduced the percentage of patients receiving a dose of fentanyl from a vial previously accessed for another patient in a high-volume otolaryngology room. © 2015 John Wiley & Sons Ltd.

  15. Dose rate and dose fractionation studies in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Netzel, B.; Schaffer, E.; Kolb, H.

    1979-01-01

    Total body irradiation (TBI) with 800-900 rads and allogeneic bone marrow transplantation according to the regimen designated by the Seattle group has induced remissions in patients with otherwise refractory acute leukemias. Relapse of leukemia after bone marrow transplantation remains the major problem, when the Seattle set up of two opposing 60 Co-sources and a low dose rate is used in TBI. Studies in dogs with TBI at various dose rates confirmed observations in mice that gastrointestinal toxicity is unlike toxicity against hemopoietic stem cells and possibly also leukemic stem cells depending on the dose rate. However, following very high single doses (2400 R) and marrow infusion acute gastrointestinal toxicity was not prevented by the lowest dose rate studied (0.5 R/min). Fractionated TBI with fractions of 600 R in addition to 1200 R (1000 rads) permitted the application of total doses up to 300 R followed by marrow infusion without irreversible toxicity. 26 dogs given 2400-3000 R have been observed for presently up to 2 years with regard to delayed radiation toxicity. This toxicity was mild in dogs given single doses at a low dose rate or fractionated TBI. Fractionated TBI is presently evaluated with allogeneic transplants in the dog before being applied to leukemic patients

  16. Development of a synthetic single crystal diamond dosimeter for dose measurement of clinical proton beams

    Science.gov (United States)

    Moignier, Cyril; Tromson, Dominique; de Marzi, Ludovic; Marsolat, Fanny; García Hernández, Juan Carlos; Agelou, Mathieu; Pomorski, Michal; Woo, Romuald; Bourbotte, Jean-Michel; Moignau, Fabien; Lazaro, Delphine; Mazal, Alejandro

    2017-07-01

    The scope of this work was to develop a synthetic single crystal diamond dosimeter (SCDD-Pro) for accurate relative dose measurements of clinical proton beams in water. Monte Carlo simulations were carried out based on the MCNPX code in order to investigate and reduce the dose curve perturbation caused by the SCDD-Pro. In particular, various diamond thicknesses were simulated to evaluate the influence of the active volume thickness (e AV) as well as the influence of the addition of a front silver resin (250 µm in thickness in front of the diamond crystal) on depth-dose curves. The simulations indicated that the diamond crystal alone, with a small e AV of just 5 µm, already affects the dose at Bragg peak position (Bragg peak dose) by more than 2% with respect to the Bragg peak dose deposited in water. The optimal design that resulted from the Monte Carlo simulations consists of a diamond crystal of 1 mm in width and 150 µm in thickness with the front silver resin, enclosed by a water-equivalent packaging. This design leads to a deviation between the Bragg peak dose from the full detector modeling and the Bragg peak dose deposited in water of less than 1.2%. Based on those optimizations, an SCDD-Pro prototype was built and evaluated in broad passive scattering proton beams. The experimental evaluation led to probed SCDD-Pro repeatability, dose rate dependence and linearity, that were better than 0.2%, 0.4% (in the 1.0-5.5 Gy min-1 range) and 0.4% (for dose higher than 0.05 Gy), respectively. The depth-dose curves in the 90-160 MeV energy range, measured with the SCDD-Pro without applying any correction, were in good agreement with those measured using a commercial IBA PPC05 plane-parallel ionization chamber, differing by less than 1.6%. The experimental results confirmed that this SCDD-Pro is suitable for measurements with standard electrometers and that the depth-dose curve perturbation is negligible, with no energy dependence and no significant dose rate

  17. Comparison of immune persistence among inactivated and live attenuated hepatitis a vaccines 2 years after a single dose

    Science.gov (United States)

    Zhang, Xiaoshu; An, Jing; Tu, Aixia; Liang, Xuefeng; Cui, Fuqiang; Zheng, Hui; Tang, Yu; Liu, Jianfeng; Wang, Xuxia; Zhang, Ningjing; Li, Hui

    2016-01-01

    ABSTRACT Objective: Compare immune persistence from one dose of each of 3 different hepatitis A vaccines when given to school-age children: a domestic, live attenuated hepatitis A vaccine (H2 vaccine); a domestic inactivated hepatitis A vaccine (Healive®); and an imported, inactivated hepatitis A vaccine (Havrix®),.Methods: School-age children were randomized into 1 of 4 groups to receive a single dose of a vaccine: H2 vaccine, Healive®, Havrix®, or hepatitis B vaccine [control]. Serum samples were collected 12 and 24 months after vaccination for measurement of anti-HAV IgG using microparticle enzyme immunoassay. Seropositivity was defined as ≥ 20 mUI/ml. We compared groups on seropositivity and geometric mean concentration (GMC). Results: Seropositive rates for the H2, Healive®, Havrix®, and control groups were 64%, 94.4%, 73%, and 1.0%, respectively, 12-months post-vaccination; and 63%, 95.6%, 72%, and 1.0%, respectively 24-months post-vaccination. Seropositivity was greater for Healive® than for H2 and Havrix® at 12 months (p-values a single dose of inactivated hepatitis A vaccine and live attenuated hepatitis A vaccine. PMID:27494260

  18. Two computational approaches for Monte Carlo based shutdown dose rate calculation with applications to the JET fusion machine

    Energy Technology Data Exchange (ETDEWEB)

    Petrizzi, L.; Batistoni, P.; Migliori, S. [Associazione EURATOM ENEA sulla Fusione, Frascati (Roma) (Italy); Chen, Y.; Fischer, U.; Pereslavtsev, P. [Association FZK-EURATOM Forschungszentrum Karlsruhe (Germany); Loughlin, M. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon, Oxfordshire, OX (United Kingdom); Secco, A. [Nice Srl Via Serra 33 Camerano Casasco AT (Italy)

    2003-07-01

    In deuterium-deuterium (D-D) and deuterium-tritium (D-T) fusion plasmas neutrons are produced causing activation of JET machine components. For safe operation and maintenance it is important to be able to predict the induced activation and the resulting shut down dose rates. This requires a suitable system of codes which is capable of simulating both the neutron induced material activation during operation and the decay gamma radiation transport after shut-down in the proper 3-D geometry. Two methodologies to calculate the dose rate in fusion devices have been developed recently and applied to fusion machines, both using the MCNP Monte Carlo code. FZK has developed a more classical approach, the rigorous 2-step (R2S) system in which MCNP is coupled to the FISPACT inventory code with an automated routing. ENEA, in collaboration with the ITER Team, has developed an alternative approach, the direct 1 step method (D1S). Neutron and decay gamma transport are handled in one single MCNP run, using an ad hoc cross section library. The intention was to tightly couple the neutron induced production of a radio-isotope and the emission of its decay gammas for an accurate spatial distribution and a reliable calculated statistical error. The two methods have been used by the two Associations to calculate the dose rate in five positions of JET machine, two inside the vacuum chamber and three outside, at cooling times between 1 second and 1 year after shutdown. The same MCNP model and irradiation conditions have been assumed. The exercise has been proposed and financed in the frame of the Fusion Technological Program of the JET machine. The scope is to supply the designers with the most reliable tool and data to calculate the dose rate on fusion machines. Results showed that there is a good agreement: the differences range between 5-35%. The next step to be considered in 2003 will be an exercise in which the comparison will be done with dose-rate data from JET taken during and

  19. Two computational approaches for Monte Carlo based shutdown dose rate calculation with applications to the JET fusion machine

    International Nuclear Information System (INIS)

    Petrizzi, L.; Batistoni, P.; Migliori, S.; Chen, Y.; Fischer, U.; Pereslavtsev, P.; Loughlin, M.; Secco, A.

    2003-01-01

    In deuterium-deuterium (D-D) and deuterium-tritium (D-T) fusion plasmas neutrons are produced causing activation of JET machine components. For safe operation and maintenance it is important to be able to predict the induced activation and the resulting shut down dose rates. This requires a suitable system of codes which is capable of simulating both the neutron induced material activation during operation and the decay gamma radiation transport after shut-down in the proper 3-D geometry. Two methodologies to calculate the dose rate in fusion devices have been developed recently and applied to fusion machines, both using the MCNP Monte Carlo code. FZK has developed a more classical approach, the rigorous 2-step (R2S) system in which MCNP is coupled to the FISPACT inventory code with an automated routing. ENEA, in collaboration with the ITER Team, has developed an alternative approach, the direct 1 step method (D1S). Neutron and decay gamma transport are handled in one single MCNP run, using an ad hoc cross section library. The intention was to tightly couple the neutron induced production of a radio-isotope and the emission of its decay gammas for an accurate spatial distribution and a reliable calculated statistical error. The two methods have been used by the two Associations to calculate the dose rate in five positions of JET machine, two inside the vacuum chamber and three outside, at cooling times between 1 second and 1 year after shutdown. The same MCNP model and irradiation conditions have been assumed. The exercise has been proposed and financed in the frame of the Fusion Technological Program of the JET machine. The scope is to supply the designers with the most reliable tool and data to calculate the dose rate on fusion machines. Results showed that there is a good agreement: the differences range between 5-35%. The next step to be considered in 2003 will be an exercise in which the comparison will be done with dose-rate data from JET taken during and

  20. Two Dimensional Verification of the Dose Distribution of Gamma Knife Model C using Monte Carlo Simulation with a Virtual Source

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae-Hoon; Kim, Yong-Kyun; Lee, Cheol Ho; Son, Jaebum; Lee, Sangmin; Kim, Dong Geon; Choi, Joonbum; Jang, Jae Yeong [Hanyang University, Seoul (Korea, Republic of); Chung, Hyun-Tai [Seoul National University, Seoul (Korea, Republic of)

    2016-10-15

    Gamma Knife model C contains 201 {sup 60}Co sources located on a spherical surface, so that each beam is concentrated on the center of the sphere. In the last work, we simulated the Gamma Knife model C through Monte Carlo simulation code using Geant4. Instead of 201 multi-collimation system, we made one single collimation system that collects source parameter passing through the collimator helmet. Using the virtual source, we drastically reduced the simulation time to transport 201 gamma circle beams to the target. Gamma index has been widely used to compare two dose distributions in cancer radiotherapy. Gamma index pass rates were compared in two calculated results using the virtual source method and the original method and measured results obtained using radiocrhomic films. A virtual source method significantly reduces simulation time of a Gamma Knife Model C and provides equivalent absorbed dose distributions as that of the original method showing Gamma Index pass rate close to 100% under 1mm/3% criteria. On the other hand, it gives a little narrow dose distribution compared to the film measurement showing Gamma Index pass rate of 94%. More accurate and sophisticated examination on the accuracy of the simulation and film measurement is necessary.

  1. Water-based squeezing flow in the presence of carbon nanotubes between two parallel disks

    Directory of Open Access Journals (Sweden)

    Haq Rizwan Ul

    2016-01-01

    Full Text Available Present study is dedicated to investigate the water functionalized carbon nanotubes squeezing flow between two parallel discs. Moreover, we have considered magnetohydrodynamics effects normal to the disks. In addition we have considered two kind of carbon nanotubes named: single wall carbon nanotubes (SWCNT and multiple wall carbon nanotubes (MWCNT with in the base fluid. Under this squeezing flow mechanism model has been constructed in the form of partial differential equation. Transformed ordinary differential equations are solved numerically with the help of Runge-Kutta-Fehlberg method. Results for velocity and temperature are constructed against all the emerging parameters. Comparison among the SWCNT and MWCNT are drawn for skin friction coefficient and local Nusselt number. Conclusion remarks are drawn under the observation of whole analysis.

  2. Multidisciplinary approach for the esophageal carcinoma with intent to conserve the esophagus centering on high-dose radiotherapy and concurrent chemotherapy

    International Nuclear Information System (INIS)

    Murakami, Masao; Kuroda, Yasumasa; Okamoto, Yoshiaki

    1997-01-01

    Forty-seven patients with operable squamous cell carcinoma of the thoracic esophagus were treated by initial concurrent chemoradiotherapy (CDDP-5 FU-44 Gy) followed by definitive high-dose of radiotherapy (CRT group: 35 patients) or surgery (CRT-S group: 12 patients). Clinical CR rate showed 86% in CRT group; and pathological CR rate 18% in CRT-S group. The overall median survival was 45 months, survival at 1, 3, 5 years being 96%, 52%, 48%, respectively. No treatment-related mortality was observed. The rate of the 'esophagus conservation' was 66%. Our results demonstrated that the multidisciplinary approach with intent to conserve the esophagus centering on high-dose radiotherapy and concurrent chemotherapy provides a significant improvement of both survival and quality of life in patients with operable esophageal carcinoma. (author)

  3. Failure Rate of Single Dose Methotrexate in Managment of Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    Feras Sendy

    2015-01-01

    Full Text Available Background. One of the treatment modalities for ectopic pregnancy is methotrexate. The purpose of this study is to identify the failure rate of methotrexate in treating patients with ectopic pregnancy as well as the risk factors leading to treatment failure. Methods. A retrospective chart review of 225 patients who received methotrexate as a primary management option for ectopic pregnancy. Failure of single dose of methotrexate was defined as drop of BHCG level less than or equal to 14% in the seventh day after administration of methotrexate. Results. 225 patients had methotrexate. Most of the patients (151 (67% received methotrexate based on the following formula: f 50 mg X body surface area. Single dose of methotrexate was successful in 72% (162/225 of the patients. 28% (63/225 were labeled as failure of single dose of methotrexate because of suboptimal drop in BhCG. 63% (40/63 of failure received a second dose of methotrexate, and 37% (23/63 underwent surgical treatment. Among patient who received initial dose of methotrexate, 71% had moderate or severe pain, and 58% had ectopic mass size of more than 4 cm on ultrasound. Conclusion. Liberal use of medical treatment of ectopic pregnancy results in 71% success rate.

  4. Failure rate of single dose methotrexate in managment of ectopic pregnancy.

    Science.gov (United States)

    Sendy, Feras; AlShehri, Eman; AlAjmi, Amani; Bamanie, Elham; Appani, Surekha; Shams, Taghreed

    2015-01-01

    Background. One of the treatment modalities for ectopic pregnancy is methotrexate. The purpose of this study is to identify the failure rate of methotrexate in treating patients with ectopic pregnancy as well as the risk factors leading to treatment failure. Methods. A retrospective chart review of 225 patients who received methotrexate as a primary management option for ectopic pregnancy. Failure of single dose of methotrexate was defined as drop of BHCG level less than or equal to 14% in the seventh day after administration of methotrexate. Results. 225 patients had methotrexate. Most of the patients (151 (67%)) received methotrexate based on the following formula: f 50 mg X body surface area. Single dose of methotrexate was successful in 72% (162/225) of the patients. 28% (63/225) were labeled as failure of single dose of methotrexate because of suboptimal drop in BhCG. 63% (40/63) of failure received a second dose of methotrexate, and 37% (23/63) underwent surgical treatment. Among patient who received initial dose of methotrexate, 71% had moderate or severe pain, and 58% had ectopic mass size of more than 4 cm on ultrasound. Conclusion. Liberal use of medical treatment of ectopic pregnancy results in 71% success rate.

  5. Correlation between the single, high dose of ingested baclofen and clinical symptoms

    Directory of Open Access Journals (Sweden)

    Jacek Sein Anand

    2017-12-01

    There is a statistically significant correlation between the dose of ingested baclofen and the presence of acute respiratory failure, and duration of mechanical ventilation. Patients who have taken a single dose of baclofen of 200 mg, or higher, should be managed in centres able to provide continuous monitoring of life functions. Those with a higher level of a single dose of baclofen ingestion (>500 mg, should be hospitalized in a Toxicology Unit or Intensive Care Unit able to provide airway support and mechanical ventilation.

  6. Distribution of 99Tcm-rh-Annexin V and its relationship with expression of survivin and Caspase-3 in tumors after a single dose of chemotherapy

    International Nuclear Information System (INIS)

    Zhang Xin; Zhang Yanjun; Tao Li; Zhu Yi; Yang Chun; Li Yaming; Zhang Jianying; Zhao Zhenzhen; Ji Xiaopeng; Zhao Ming; Tian Aijuan

    2008-01-01

    Objective: Recently, molecular imaging for detecting cellular apoptosis is developing rapidly. The aim of the study was to determine the effectiveness of imaging with 99 Tc m labelled recombinant human Annexin V ( 99 Tc m -rh-Annexin V) as a reflection of apoptosis in tumor, and related its distribution with expression of Survivin and Caspase-3 after a single dose of chemotherapy. Methods: Eight days after being inoculated with allogenic hepatoma cells (Hca-F25) into right axillary fossa, the mice (purebred 615) were randomly divided into two groups (control group A, n=9; and treated group B, n=10). Group B was received a single dose of chemotherapy intraperitoneally (cyclophosphamide, 150 mg/kg). Groups A and B were given 99 Tc m -rh-AnnexinV (3.7 MBq·0.5 μg -1 per mouse) intravenously 20 h later. Four hours after 99 Tc m -rh-Annexin V injection, the animals were imaged and sacrificed, and the tumor samples were weighed and the radioactivity was determined in a well-counter. The accumulation of 99 Tc m -rh-Annexin V in tumor was expressed as the percentage activity of injection dose per gram of tissue (% ID/g). Tumor cell apoptosis was examined by terminal deoxynueleotidyl transferase-mediated deoxyuridine triphosphate nick-end labeling (TUNEL) method, and the expression of Survivin and Caspase-3 in tumor were determined with immunohistochemical method. SPSS 10.0 was used for data analysis. Results: Single dose chemotherapy tsignificantly increased the tumor uptake of 99 Tc m -rh-Annexin V [(0.478 ± 0.123)% ID/g vs (0.332 ± 0.061)% ID/g] and the positive number of TUNEL [(18.030 ± 5.600) cells/field vs (6.744 ± 2.325) cells/field], as well as the expression of Caspase-3 [(3.266 ± 0.482)% vs (2.387 ± 0.387)%, F was 10.502, 31.507, 18.971, respectively, all P 99 Tc m -rh-Annexin V correlated positively well with the expression of Caspase-3 and negatively with the expression of Survivin (P 99 Tc m -rh-Annexin V can not only reflect the extent of apoptosis

  7. Palonosetron-A Single-Dose Antiemetic Adjunct for Hepatic Artery Radioembolization: A Feasibility Study

    International Nuclear Information System (INIS)

    Siddiqi, Nasir H.; Khan, Atif J.; Devlin, Phillip M.

    2009-01-01

    Nausea and vomiting may occur in a significant minority of patients following hepatic artery embolization with yttrium-90 spheres (K. T. Sato et al. Radiology 247:507-515, 2008). This encumbers human and economic resources and undercuts the assertion that it is as a well-tolerated outpatient treatment. A single intravenous dose of palonosetron HCl was administered before hepatic artery embolization with yttrium-90 spheres to ameliorate posttreatment nausea and vomiting, in 23 consecutive patients. The patients were discharged the day of procedure on oral antiemetics, steroids, and blockers of gastric acid release. All patients had clinical and laboratory evaluation at 2 weeks after the procedure. The data were gathered and reviewed retrospectively. At 2-week follow-up, none reported significant nausea, vomiting, additional antiemetic use, need for parenteral therapy, hospital readmission, or palonosetron-related side effects. All patients recovered from postembolization symptoms within a week after treatment. In conclusion, this retrospective study suggests that single-dose palonosetron is feasible, safe, and effective for acute and delayed nausea and vomiting in this group of patients. The added cost may be offset by benefits.

  8. Bolus dose response characteristics of single chain urokinase plasminogen activator and tissue plasminogen activator in a dog model of arterial thrombosis.

    Science.gov (United States)

    Badylak, S F; Voytik, S; Klabunde, R E; Henkin, J; Leski, M

    1988-11-15

    Tissue plasminogen activator (t-PA) and single chain urokinase-plasminogen activator (scu-PA) are relatively "fibrin-specific" thrombolytic drugs with short plasma half lives of 6-8 minutes. Most treatment regimens with these agents utilize a bolus injection followed by continuous drug infusion, usually combined with anticoagulant therapy. The purpose of this study was to establish the dose-response characteristics for scu-PA and t-PA, when given as a single intravenous bolus injection, in a dog model of arterial thrombosis. Eight groups of 6 dogs each were given one of the following doses of scu-PA (mg/kg): 0.20, 0.50, 1.00, 2.00; or t-PA: 0.05, 0.10, 0.20; or an equivalent amount of saline (control group). All doses were given as a single bolus injection 60 minutes after formation of a totally occlusive femoral artery thrombus. Thrombolysis was measured by monitoring the continuous decrement of 125I activity from a radiolabelled thrombus. Ninety minutes after drug injection, all scu-PA treated dogs showed greater thrombolysis (30%, 45%, 56%, and 67%, respectively) than the control group (15%, p less than 0.01). The 0.10 and 0.20 mg/kg t-PA treated dogs showed greater thrombolysis (35% and 49%, respectively) than the control group (15%, p less than 0.01). Both scu-PA and t-PA caused a partial and dose-dependent decrease in alpha 2-antiplasmin activity but scu-PA caused a greater depletion (72% vs. 18%, respectively, p less than 0.05) at 60 minutes after the highest dose of drug administration. Both drugs showed a longer than expected thrombolytic effect based upon the known half lives. Neither drug caused significant changes in the prothrombin time, activated partial thromboplastin time, thrombin time, hematocrit, platelet count, or fibrin degradation product concentration. Single bolus injections of scu-PA and t-PA produce safe and effective thrombolysis in this dog model of arterial thrombosis.

  9. A novel two-level dynamic parallel data scheme for large 3-D SN calculations

    International Nuclear Information System (INIS)

    Sjoden, G.E.; Shedlock, D.; Haghighat, A.; Yi, C.

    2005-01-01

    We introduce a new dynamic parallel memory optimization scheme for executing large scale 3-D discrete ordinates (Sn) simulations on distributed memory parallel computers. In order for parallel transport codes to be truly scalable, they must use parallel data storage, where only the variables that are locally computed are locally stored. Even with parallel data storage for the angular variables, cumulative storage requirements for large discrete ordinates calculations can be prohibitive. To address this problem, Memory Tuning has been implemented into the PENTRAN 3-D parallel discrete ordinates code as an optimized, two-level ('large' array, 'small' array) parallel data storage scheme. Memory Tuning can be described as the process of parallel data memory optimization. Memory Tuning dynamically minimizes the amount of required parallel data in allocated memory on each processor using a statistical sampling algorithm. This algorithm is based on the integral average and standard deviation of the number of fine meshes contained in each coarse mesh in the global problem. Because PENTRAN only stores the locally computed problem phase space, optimal two-level memory assignments can be unique on each node, depending upon the parallel decomposition used (hybrid combinations of angular, energy, or spatial). As demonstrated in the two large discrete ordinates models presented (a storage cask and an OECD MOX Benchmark), Memory Tuning can save a substantial amount of memory per parallel processor, allowing one to accomplish very large scale Sn computations. (authors)

  10. The specificity of learned parallelism in dual-memory retrieval.

    Science.gov (United States)

    Strobach, Tilo; Schubert, Torsten; Pashler, Harold; Rickard, Timothy

    2014-05-01

    Retrieval of two responses from one visually presented cue occurs sequentially at the outset of dual-retrieval practice. Exclusively for subjects who adopt a mode of grouping (i.e., synchronizing) their response execution, however, reaction times after dual-retrieval practice indicate a shift to learned retrieval parallelism (e.g., Nino & Rickard, in Journal of Experimental Psychology: Learning, Memory, and Cognition, 29, 373-388, 2003). In the present study, we investigated how this learned parallelism is achieved and why it appears to occur only for subjects who group their responses. Two main accounts were considered: a task-level versus a cue-level account. The task-level account assumes that learned retrieval parallelism occurs at the level of the task as a whole and is not limited to practiced cues. Grouping response execution may thus promote a general shift to parallel retrieval following practice. The cue-level account states that learned retrieval parallelism is specific to practiced cues. This type of parallelism may result from cue-specific response chunking that occurs uniquely as a consequence of grouped response execution. The results of two experiments favored the second account and were best interpreted in terms of a structural bottleneck model.

  11. Effect of treatment with single total-dose intravenous iron versus daily oral iron(III-hydroxide polymaltose on moderate puerperal iron-deficiency anemia

    Directory of Open Access Journals (Sweden)

    Iyoke CA

    2017-05-01

    Full Text Available Chukwuemeka Anthony Iyoke,1 Fausta Chioma Emegoakor,1 Euzebus Chinonye Ezugwu,1 Lucky Osaheni Lawani,2 Leonard Ogbonna Ajah,1 Jude Anazoeze Madu,3 Hyginus Uzo Ezegwui,1 Frank Okechukwu Ezugwu4 1Department of Obstetrics and Gynaecology, University of Nigeria, Enugu Campus, 2Department of Obstetrics and Gynaecology, Federal Teaching Hospital, Abakaliki, 3Department of Haematology, University of Nigeria, Nsukka, 4Department of Obstetrics and Gynaecology, College of Medicine, Enugu State University, Enugu, Nigeria Background: Iron-deficiency anemia is the most common nutritional cause of anemia in pregnancy and is often responsible for puerperal anemia. Puerperal anemia can impair postpartum maternal and neonatal well-being. Objective: To determine the effect of treatment of moderate puerperal iron-deficiency anemia using a single intravenous total-dose iron dextran versus daily single dose oral iron(III-hydroxide polymaltose. Methodology: A randomized controlled study in which postpartum women with moderate iron-deficiency anemia were randomized into treatment with either a single total-dose intravenous iron dextran or with daily single doses of oral iron(III-hydroxide polymaltose tablets for 6 weeks. Effects on hemoglobin concentration using either method were compared at 6 weeks postpartum. Analysis was per protocol using SPSS version 17 for windows. P-values ≤0.05 were considered significant. Results: Two hundred eighty-four women were recruited for the study: 142 women received single total dose intravenous infusion of iron dextran while 142 received daily oral iron(III-hydroxide polymaltose tablets. Approximately 84.0% (237/282 completed the study and were analyzed including 81% (115/142 of those randomized to injectable iron therapy compared to 85.9% (122/142 of those randomized to oral treatment. The proportions of women who had attained hemoglobin concentration of at least 10 g/dL by the 6 weeks postpartum visit did not differ

  12. Comparison of pacing algorithms to avoid unnecessary ventricular pacing in patients with sick sinus node syndrome: a single-centre, observational, parallel study.

    Science.gov (United States)

    Poghosyan, Hermine R; Jamalyan, Smbat V

    2012-10-01

    Reduction of unnecessary ventricular pacing (uVP) is an essential component in the treatment strategy in any pacing population in general. The aim of this study was to evaluate the efficacy of different algorithms to reduce uVP in an adult population with sick sinus syndrome (SSS) treated outside of clinical trials. Evaluation of the relationship between different types of pacing algorithms and clinical outcomes is also provided. This was a single-centre, observational, parallel study, based on retrospective analysis of the Arrhythmology Cardiology Center of Armenia electronic clinical database. This study evaluated atrial pacing percentage (AP%), ventricular pacing percentage (VP%), and the incidence of atrial high rate episodes in 56 patients with SSS using three different pacing strategies: managed VP, search atrioventricular (AV), and fixed long AV. We did not find statistically significant differences in the amount of VP between the groups. Although the atrial high rate percentage (AHR%) tended to be higher in the fixed long AV group, this difference was not statistically significant. Mean VP% and AP% were similar in all three groups. In our study, all three programmed strategies produced the same mean AP% and VP%, and were equally efficient in uVP reduction. There was no relationship between chosen algorithms and the incidence of pacemaker syndrome, hospitalizations, or change in New York Heart Association class. The percentage of AHR was not associated with pacing strategy or co-morbidities but showed borderline correlation with left atrial size.

  13. Suitability Of Nitisinone In Alkaptonuria 1 (SONIA 1): an international, multicentre, randomised, open-label, no-treatment controlled, parallel-group, dose-response study to investigate the effect of once daily nitisinone on 24-h urinary homogentisic acid excretion in patients with alkaptonuria after 4 weeks of treatment.

    Science.gov (United States)

    Ranganath, Lakshminarayan R; Milan, Anna M; Hughes, Andrew T; Dutton, John J; Fitzgerald, Richard; Briggs, Michael C; Bygott, Helen; Psarelli, Eftychia E; Cox, Trevor F; Gallagher, James A; Jarvis, Jonathan C; van Kan, Christa; Hall, Anthony K; Laan, Dinny; Olsson, Birgitta; Szamosi, Johan; Rudebeck, Mattias; Kullenberg, Torbjörn; Cronlund, Arvid; Svensson, Lennart; Junestrand, Carin; Ayoob, Hana; Timmis, Oliver G; Sireau, Nicolas; Le Quan Sang, Kim-Hanh; Genovese, Federica; Braconi, Daniela; Santucci, Annalisa; Nemethova, Martina; Zatkova, Andrea; McCaffrey, Judith; Christensen, Peter; Ross, Gordon; Imrich, Richard; Rovensky, Jozef

    2016-02-01

    Alkaptonuria (AKU) is a serious genetic disease characterised by premature spondyloarthropathy. Homogentisate-lowering therapy is being investigated for AKU. Nitisinone decreases homogentisic acid (HGA) in AKU but the dose-response relationship has not been previously studied. Suitability Of Nitisinone In Alkaptonuria 1 (SONIA 1) was an international, multicentre, randomised, open-label, no-treatment controlled, parallel-group, dose-response study. The primary objective was to investigate the effect of different doses of nitisinone once daily on 24-h urinary HGA excretion (u-HGA24) in patients with AKU after 4 weeks of treatment. Forty patients were randomised into five groups of eight patients each, with groups receiving no treatment or 1 mg, 2 mg, 4 mg and 8 mg of nitisinone. A clear dose-response relationship was observed between nitisinone and the urinary excretion of HGA. At 4 weeks, the adjusted geometric mean u-HGA24 was 31.53 mmol, 3.26 mmol, 1.44 mmol, 0.57 mmol and 0.15 mmol for the no treatment or 1 mg, 2 mg, 4 mg and 8 mg doses, respectively. For the most efficacious dose, 8 mg daily, this corresponds to a mean reduction of u-HGA24 of 98.8% compared with baseline. An increase in tyrosine levels was seen at all doses but the dose-response relationship was less clear than the effect on HGA. Despite tyrosinaemia, there were no safety concerns and no serious adverse events were reported over the 4 weeks of nitisinone therapy. In this study in patients with AKU, nitisinone therapy decreased urinary HGA excretion to low levels in a dose-dependent manner and was well tolerated within the studied dose range. EudraCT number: 2012-005340-24. Registered at ClinicalTrials.gov: NCTO1828463. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Effect of Low-Dose Irradiation on Biochemical and Immunological Responses

    International Nuclear Information System (INIS)

    Shabon, M.H.; Sayed, Z.S.; El-Gawish, M.A.; Mahdy, E.M.E.; Shosha, W.Gh.

    2008-01-01

    Lipid peroxidation (Malondialdehyde), Lactate dehydrogenase, Iron Concentration, IL-6 and IL-1β concentration were determined in Seventy-two male albino rats divided in two main groups. The first one was subdivided into 7 subgroups; control and 6 irradiated subgroups with 0.1, 0.2, 0.3, 0.5, 0.7, and 1 Gy single dose of gamma radiation. The other was subdivided into 4 irradiated subgroups with fractionated dose .-radiation of 0.3, 0.7 and 1 Gy with 0.1 Gy per day and the last subgroup 1 Gy with 0.2 Gy daily. All animals were sacrificed after three days of the last irradiation dose. The results revealed that all biochemical parameters were increased in rats exposed to fractionated more than single doses. In conclusion, the data of this study highlight on the beneficial and stimulatory effect of low ionizing radiation doses (≥ 1Gy) whether single or fractionated on some biochemical and immunological parameters. These findings may be fruitful for those who undergo radiotherapy as well as the dose-effect relationship

  15. Parallel treatment of simulation particles in particle-in-cell codes on SUPRENUM

    International Nuclear Information System (INIS)

    Seldner, D.

    1990-02-01

    This report contains the program documentation and description of the program package 2D-PLAS, which has been developed at the Nuclear Research Center Karlsruhe in the Institute for Data Processing in Technology (IDT) under the auspices of the BMFT. 2D-PLAS is a parallel program version of the treatment of the simulation particles of the two-dimensional stationary particle-in-cell code BFCPIC which has been developed at the Nuclear Research Center Karlsruhe. This parallel version has been designed for the parallel computer SUPRENUM. (orig.) [de

  16. Effect of two prophylactic bolus vitamin D dosing regimens (1000 IU/day vs. 400 IU/day) on bone mineral content in new-onset and infrequently-relapsing nephrotic syndrome: a randomised clinical trial.

    Science.gov (United States)

    Muske, Sravani; Krishnamurthy, Sriram; Kamalanathan, Sadish Kumar; Rajappa, Medha; Harichandrakumar, K T; Sivamurukan, Palanisamy

    2018-02-01

    To examine the efficacy of two vitamin D dosages (1000 vs. 400 IU/day) for osteoprotection in children with new-onset and infrequently-relapsing nephrotic syndrome (IFRNS) receiving corticosteroids. This parallel-group, open label, randomised clinical trial enrolled 92 children with new-onset nephrotic syndrome (NS) (n = 28) or IFRNS (n = 64) to receive 1000 IU/day (Group A, n = 46) or 400 IU/day (Group B, n = 46) vitamin D (administered as a single bolus initial supplemental dose) by block randomisation in a 1:1 allocation ratio. In Group A, vitamin D (cholecalciferol in a Calcirol® sachet) was administered in a single stat dose of 84,000 IU on Day 1 of steroid therapy (for new-onset NS), calculated for a period of 12 weeks@1000 IU/day) and 42,000 IU on Day 1 of steroid therapy (for IFRNS, calculated for a period of 6 weeks@1000 IU/day). In Group B, vitamin D (cholecalciferol in a Calcirol® sachet) was administered as a single stat dose of 33,600 IU on Day 1 of steroid therapy (for new-onset NS, calculated for a period of 12 weeks@400 IU/day) and 16,800 IU on Day 1 of steroid therapy (for IFRNS, calculated for a period of 6 weeks@400 IU/day). The proportionate change in bone mineral content (BMC) was analysed in both groups after vitamin D supplementation. Of the 92 children enrolled, 84 (n = 42 new onset, n = 42 IFRNS) completed the study and were included in the final analysis. Baseline characteristics including initial BMC, bone mineral density, cumulative prednisolone dosage and serum 25-hydroxycholecalciferol levels were comparable in the two groups. There was a greater median proportionate change in BMC in the children who received 1000 IU/day vitamin D (3.25%, IQR -1.2 to 12.4) than in those who received 400 IU/day vitamin D (1.2%, IQR -2.5 to 3.8, p = 0.048). The difference in proportionate change in BMC was only statistically significant in the combined new-onset and IFRNS, but not for IFRNS alone. There was a greater

  17. Comparison of two dose regimens of ibuprofen for the closure of patent ductus arteriosus in preterm newborns,

    Directory of Open Access Journals (Sweden)

    Laura Vargas Dornelles

    2016-06-01

    Full Text Available Abstract Objective: To compare the efficacy of intravenous ibuprofen at high (20-10-10 mg/kg/dose and low doses (10-5-5 mg/kg/dose the closure of patent ductus arteriosus in preterm newborns. Methods: A cohort study with historical control of newborns that received high- and low-dose intravenous ibuprofen, from 2010 to 2013 in a neonatal intensive care unit, for closure of the patent ductus arteriosus, documented by echocardiography. Secondary outcomes included the number of ibuprofen cycles, incidence of bronchopulmonary dysplasia, necrotizing enterocolitis, changes in renal function, and death. Results: Seventy-seven patients received three doses of ibuprofen for the treatment of patent ductus arteriosus, with 33 receiving high-dose and 44 low-dose therapy. The ductus closed after the first cycle in 25 (56.8% low-dose patients and in 17 (51.5% high-dose patients (p > 0.99. Sixteen patients received a second cycle of ibuprofen, and the ductus closed in 50% after low-dose and in 60% after high-dose therapy (p > 0.99. Seven patients required surgery for ductus closure, 13.6% in the low-dose group and 3% in the high-dose group (p = 0.22. Thirty-nine patients developed bronchopulmonary dysplasia, 50% in the low-dose group and 51.5% in the high-dose group (p > 0.99. Twenty-two (50% low-dose patients died vs. 15 (45.5% high-dose patients (p = 0.86. Conclusions: There was no difference in closure of the ductus arteriosus or occurrence of adverse effects between the two dose regimens.

  18. Structural comparison of anodic nanoporous-titania fabricated from single-step and three-step of anodization using two paralleled-electrodes anodizing cell

    Directory of Open Access Journals (Sweden)

    Mallika Thabuot

    2016-02-01

    Full Text Available Anodization of Ti sheet in the ethylene glycol electrolyte containing 0.38wt% NH4F with the addition of 1.79wt% H2O at room temperature was studied. Applied potential of 10-60 V and anodizing time of 1-3 h were conducted by single-step and three-step of anodization within the two paralleled-electrodes anodizing cell. Their structural and textural properties were investigated by X-ray diffraction (XRD and scanning electron microscopy (SEM. After annealing at 600°C in the air furnace for 3 h, TiO2-nanotubes was transformed to the higher proportion of anatase crystal phase. Also crystallization of anatase phase was enhanced as the duration of anodization as the final step increased. By using single-step of anodization, pore texture of oxide film was started to reveal at the applied potential of 30 V. Better orderly arrangement of the TiO2-nanotubes array with larger pore size was obtained with the increase of applied potential. The applied potential of 60 V was selected for the three-step of anodization with anodizing time of 1-3 h. Results showed that the well-smooth surface coverage with higher density of porous-TiO2 was achieved using prolonging time at the first and second step, however, discontinuity tube in length was produced instead of the long-vertical tube. Layer thickness of anodic oxide film depended on the anodizing time at the last step of anodization. More well arrangement of nanostructured-TiO2 was produced using three-step of anodization under 60 V with 3 h for each step.

  19. Studies on diversion cross-flow between two parallel channels communicating by a lateral slot. II

    International Nuclear Information System (INIS)

    Tapucu, A.; Merilo, M.

    1977-01-01

    The axial pressure variations of two parallel channels with single phase flows communicating by a long lateral slot have been studied experimentally. Using mass and momentum conservation principles, the axial pressure variations have been derived in terms of two parameters ksub(d) and ksub(r), for donor and recipient channels, respectively. These parameters include the combined effect of fluid transferred from donor to recipient channel, and drag force brought on by the connection gap, and are functions of the velocities and slot geometry parameters. A pressure difference oscillation between channels along the slot has been detected which is sinusoidal with wave lengths which seem to be a function of the gap clearance. (Auth.)

  20. Placental and milk transfer, disposition and elimination of a single oral dose of [14C acetyl] acephate in Sprague Dawley rats

    International Nuclear Information System (INIS)

    Bakry, N.M.; Salama, A.K.; Abou-Donia, M.B.

    1991-01-01

    A single oral dose of 40 mg/kg (6.4 μCi/kg) of [ 14 C acetyl]acephate was administered on day 18 of gestation to pregnant Sprague Dawley rats. Eight groups of three rats were killed after 10 min and 0.5, 1, 3, 6, 12, 24, and 48 hr. At the end of the 48 hr experimental period, a total of 22.38% of the dose was exhaled as carbon dioxide, while only 1.25% and 0.60% of the dose were eliminated in the urine and feces, respectively. Trace amount (0.03% of the dose) was recovered in expired air as volatile materials. Radioactive acephate was rapidly absorbed and distributed in the tissues, with levels in most tissues reaching a peak concentration within 1 to 3 hr. The highest concentration of radioactivity was present in the maternal stomach followed by the liver. A total of 0.72% of the dose was recovered in the fetus. In another study, a single oral dose of 40 mg/kg [ 14 C acetyl]acephate was administered to the dams right after delivery. Nursing and suckling groups were killed at intervals of 1, 3, 6, 12, 24, 36, and 48 hr after dosing. Generally, the highest concentrations of radioactivity were present in the stomach, small intestine, liver, lung, and kidneys. A total of 0.96% of the dose was recovered in the sucklings

  1. The effects of A single dose of gamma-rays applied on the head on behavior of rats in Morris's water maze and in the open field test

    International Nuclear Information System (INIS)

    Smajda, B.; Kiskova, J.; Lievajova, K.; Capicikova, M.

    2006-01-01

    The effects of a sublethal dose of gamma-rays applied on the head on selected behavioral parameters were investigated in this study. Adult male Sprague-Dowley rats (n=9) were irradiated with a single dose of 20 Gy of gamma-rays from a 60 Co radiation source. The irradiated animals as well as sham-irradiated controls were tested daily in Morris water maze (MWM) (2 sessions per day) and in the open field test. The ability of spatial learning given by latency time to find the hidden platform was followed in MWM. The horizontal and vertical locomotion, the number of crossings of the center of the field and the washing behavior were recorded during an 8-minute test in the open field. The results obtained show, that radiation didn't altered significantly the dynamic of learning in MWM during the experiment. The level of horizontal and vertical locomotory activity in open field was lower in irradiated group in comparison with controls. The number of the crossings of the field's center, related to the level of anxiozity of animals was non-significantly lower in irradiated animals, whereas no differences in number of washing between both groups were detected. The results point to differences in radiosensitivity in various behavioral parameters in rats, maybe due to different level of their control and coordination in CNS. (authors)

  2. Laparoscopic versus open distal pancreatectomy for pancreatic ductal adenocarcinoma: a single-center experience.

    Science.gov (United States)

    Zhang, Ai-Bin; Wang, Ye; Hu, Chen; Shen, Yan; Zheng, Shu-Sen

    2017-06-01

    The aim of this study was to compare complications and oncologic outcomes of patients undergoing laparoscopic distal pancreatectomy (LDP) and open distal pancreatectomy (ODP) at a single center. Distal pancreatectomies performed for pancreatic ductal adenocarcinoma during a 4-year period were included in this study. A retrospective analysis of a database of this cohort was conducted. Twenty-two patients underwent LDP for pancreatic ductal adenocarcinoma, in comparison to seventy-six patients with comparable tumor characteristics treated by ODP. No patients with locally advanced lesions were included in this study. Comparing LDP group to ODP group, there were no significant differences in operation time (P=0.06) or blood loss (P=0.24). Complications (pancreatic fistula, P=0.62; intra-abdominal abscess, P=0.44; postpancreatectomy hemorrhage, P=0.34) were similar. There were no significant differences in the number of lymph nodes harvested (11.2±4.6 in LDP group vs. 14.4±5.5 in ODP group, P=0.44) nor the rate of patients with positive lymph nodes (36% in LDP group vs. 41% in ODP group, P=0.71). Incidence of positive margins was similar (9% in LDP group vs. 13% in ODP group, P=0.61). The mean overall survival time was (29.6±3.7) months for the LDP group and (27.6±2.1) months for ODP group. There was no difference in overall survival between the two groups (P=0.34). LDP is a safe and effective treatment for selected patients with pancreatic ductal adenocarcinoma. A slow-compression of pancreas tissue with the GIA stapler is effective in preventing postoperative pancreatic fistula. The oncologic outcome is comparable with the conventional open approach. Laparoscopic radical antegrade modular pancreatosplenectomy contributed to oncological clearance.

  3. Single-dose intra-articular bupivacaine plus morphine after knee arthroscopic surgery: a meta-analysis of randomised placebo-controlled studies

    Science.gov (United States)

    Wang, Yi-lun; Zeng, Chao; Xie, Dong-xing; Yang, Ye; Wei, Jie; Yang, Tuo; Li, Hui; Lei, Guang-hua

    2015-01-01

    Objectives To evaluate the efficacy and safety of single-dose intra-articular bupivacaine plus morphine after knee arthroscopic surgery. Design Meta-analysis. Data sources and study eligibility criteria A comprehensive literature search, using Medline (1966–2014), the Cochrane Central Register of Controlled Trials and Embase databases, was conducted to identify randomised placebo-controlled trials that used a combination of single-dose intra-articular bupivacaine and morphine for postoperative pain relief. Results 12 articles were included in this meta-analysis. The mean visual analogue scale (VAS) scores of the bupivacaine plus morphine group were significantly lower than those of the placebo group (weighted mean difference (WMD) −1.75; 95% CI −2.16 to −1.33; pbupivacaine plus morphine group were also significantly lower than those of the placebo group (WMD −1.46; 95% CI −1.63 to −1.29; pbupivacaine plus morphine after knee arthroscopic surgery is effective for pain relief, and its short-term side effects remain similar to saline placebo. PMID:26078306

  4. Two-step irradiance schedule versus single-dose tramadol sustained-release tablets for pain control during topical 5-aminolevulinic acid-photodynamic therapy of condyloma acuminatum in Chinese patients: a randomized comparative study.

    Science.gov (United States)

    Mchepange, Uwesu O; Huang, Chun-Yan; Sun, Yi; Tu, Ya-Ting; Tao, Juan

    2014-07-01

    Photodynamic therapy with 5-aminolevulinic acid (ALA-PDT) offers promising results for the treatment of condyloma acuminatum. However, patients have to dwell with pain to benefit from this otherwise effective and safe "off-label" treatment modality. Several techniques have been explored to control ALA-PDT-induced pain, but the desperate search for a universally accepted method is still ongoing. This study compares the two-step irradiance approach with single-dose administration of 100 mg tramadol sustained-release tablets for pain induced by ALA-PDT of condyloma acuminatum in Chinese patients. Adult Chinese patients with condyloma acuminatum were enrolled in a randomized comparative study. Pain levels were compared using the Numeric Rating Scale (NRS) at pre-defined assessment points during and after irradiation. The pain was dominated by characteristics such as burning and pricking and was almost always local and superficial. The median pain scores were lower in the two-step irradiance group at 1 minute (U = 621.5, P = 0.002) but higher at 20 minutes (U = 585.5, P = 0.002). The median pain scores between the two groups did not differ significantly at other assessment points. The pain was moderate in both groups and peaked earlier in the analgesics group (median: 5 minutes) but later in the two-step irradiance group (median: 15 minutes). The pain was generally mild. The median pain scores were equal at each assessment point, except at 3 hours where the median was lower in the analgesics group (1.0) as compared with the two-step irradiance group (2.0) (U = 725.0, P = 0.056). Pain in the two-step irradiance protocol is irradiance-dependent. The two-step irradiance approach produces significant benefits over analgesics during the initial stages of therapy but analgesics offer significant benefits thereafter. There are potential benefits of combining the two approaches in minimizing ALA-PDT-induced pain. © 2014 Wiley Periodicals

  5. Psychometrics of shared decision making and communication as patient centered measures for two language groups.

    Science.gov (United States)

    Alvarez, Kiara; Wang, Ye; Alegria, Margarita; Ault-Brutus, Andrea; Ramanayake, Natasha; Yeh, Yi-Hui; Jeffries, Julia R; Shrout, Patrick E

    2016-09-01

    Shared decision making (SDM) and effective patient-provider communication are key and interrelated elements of patient-centered care that impact health and behavioral health outcomes. Measurement of SDM and communication from the patient's perspective is necessary in order to ensure that health care systems and individual providers are responsive to patient views. However, there is a void of research addressing the psychometric properties of these measures with diverse patients, including non-English speakers, and in the context of behavioral health encounters. This study evaluated the psychometric properties of 2 patient-centered outcome measures, the Shared Decision-Making Questionnaire-9 (SDM-Q) and the Kim Alliance Scale-Communication subscale (KAS-CM), in a sample of 239 English and Spanish-speaking behavioral health patients. One dominant factor was found for each scale and this structure was used to examine whether there was measurement invariance across the 2 language groups. One SDM-Q item was inconsistent with the configural invariance comparison and was removed. The remaining SDM-Q items exhibited strong invariance, meaning that item loadings and item means were similar across the 2 groups. The KAS-CM items had limited variability, with most respondents indicating high communication levels, and the invariance analysis was done on binary versions of the items. These had metric invariance (loadings the same over groups) but several items violated the strong invariance test. In both groups, the SDM-Q had high internal consistency, whereas the KAS-CM was only adequate. These findings help interpret results for individual patients, taking into account cultural and linguistic differences in how patients perceive SDM and patient-provider communication. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  6. Bioavailability of two single-dose oral formulations of omeprazole 20 mg: an open-label, randomized sequence, two-period crossover comparison in healthy Mexican adult volunteers.

    Science.gov (United States)

    Poo, Jorge Luis; Galán, Juan Francisco; Rosete, Alejandra; de Lago, Alberto; Oliva, Iván; González-de la Parra, Mario; Jiménez, Patricia; Burke-Fraga, Victoria; Namur, Salvador

    2008-04-01

    Omeprazole is a proton-pump inhibitor that acts to reduce acid secretion in the stomach and is used for treating various acid-related gastrointestinal disorders. There are several generic formulations of omeprazole available in Mexico; however, a literature search failed to identify published data concerning the bioavailability of these formulations in the Mexican population. The aim of this study was to compare the bioavailability of 2 oral formulations of omeprazole 20-mg capsules, marketed for use in Mexico, in healthy volunteers: Inhibitron (test formulation) and LosecA 20 mg (reference formulation). This study used a single-dose, open-label, randomized sequence, 2 x 2 crossover (2 administration periods x 2 treatments) design to compare the 2 formulations. Eligible subjects were healthy adult Mexican volunteers of both sexes. Subjects were randomly assigned in a 1:1 ratio to receive a single 20-mg dose of the test formulation followed by the reference formulation, or vice versa, with a 7-day washout period between administration periods. After a 12-hour (overnight) fast, subjects received a single, 20-mg dose of the corresponding formulation. Plasma samples were obtained over a 12-hour period after administration. Plasma omeprazole concentrations were analyzed by a nonstereospecific high-performance liquid chromatography method. For analysis of pharmacokinetic properties, including C(max), AUC from time 0 (baseline) to time t (AUC(0-t)), and AUC from baseline to infinity (AUC(0-infinity)), blood samples were drawn at baseline and 0.17, 0.33, 0.50, 0.75, 1, 1.25, 1.50, 1.75, 2, 2.50, 3, 4, 6, 8, and 12 hours after administration. The formulations were considered bioequivalent if the natural log (ln)-transformed ratios of C(max) and AUC were within the predetermined equivalence range of 80% to 125%, and if P disability, or required intervention to prevent permanent impairment or damage. Thirty-four subjects were enrolled and completed the study (25 men and 9

  7. Two- and three-dimensional magnetoinductive particle codes with guiding center electron motion

    International Nuclear Information System (INIS)

    Geary, J.L.; Tajima, T.; Leboeuf, J.N.; Zaidman, E.G.; Han, J.H.

    1986-07-01

    A magnetoinductive (Darwin) particle simulation model developed for examining low frequency plasma behavior with large time steps is presented. Electron motion perpendicular to the magnetic field is treated as massless keeping only the guiding center motion. Electron motion parallel to the magnetic field retains full inertial effects as does the ion motion. This model has been implemented in two and three dimensions. Computational tests of the equilibrium properties of the code are compared with linear theory and the fluctuation dissipation theorem. This code has been applied to the problems of Alfven wave resonance heating and twist-kink modes

  8. Vectorization, parallelization and porting of nuclear codes (vectorization and parallelization). Progress report fiscal 1998

    International Nuclear Information System (INIS)

    Ishizuki, Shigeru; Kawai, Wataru; Nemoto, Toshiyuki; Ogasawara, Shinobu; Kume, Etsuo; Adachi, Masaaki; Kawasaki, Nobuo; Yatake, Yo-ichi

    2000-03-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system, the AP3000 system and the Paragon system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 12 codes in fiscal 1998. These results are reported in 3 parts, i.e., the vectorization and parallelization on vector processors part, the parallelization on scalar processors part and the porting part. In this report, we describe the vectorization and parallelization on vector processors. In this vectorization and parallelization on vector processors part, the vectorization of General Tokamak Circuit Simulation Program code GTCSP, the vectorization and parallelization of Molecular Dynamics NTV (n-particle, Temperature and Velocity) Simulation code MSP2, Eddy Current Analysis code EDDYCAL, Thermal Analysis Code for Test of Passive Cooling System by HENDEL T2 code THANPACST2 and MHD Equilibrium code SELENEJ on the VPP500 are described. In the parallelization on scalar processors part, the parallelization of Monte Carlo N-Particle Transport code MCNP4B2, Plasma Hydrodynamics code using Cubic Interpolated Propagation Method PHCIP and Vectorized Monte Carlo code (continuous energy model / multi-group model) MVP/GMVP on the Paragon are described. In the porting part, the porting of Monte Carlo N-Particle Transport code MCNP4B2 and Reactor Safety Analysis code RELAP5 on the AP3000 are described. (author)

  9. Parallel thermal radiation transport in two dimensions

    International Nuclear Information System (INIS)

    Smedley-Stevenson, R.P.; Ball, S.R.

    2003-01-01

    This paper describes the distributed memory parallel implementation of a deterministic thermal radiation transport algorithm in a 2-dimensional ALE hydrodynamics code. The parallel algorithm consists of a variety of components which are combined in order to produce a state of the art computational capability, capable of solving large thermal radiation transport problems using Blue-Oak, the 3 Tera-Flop MPP (massive parallel processors) computing facility at AWE (United Kingdom). Particular aspects of the parallel algorithm are described together with examples of the performance on some challenging applications. (author)

  10. Parallel thermal radiation transport in two dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Smedley-Stevenson, R.P.; Ball, S.R. [AWE Aldermaston (United Kingdom)

    2003-07-01

    This paper describes the distributed memory parallel implementation of a deterministic thermal radiation transport algorithm in a 2-dimensional ALE hydrodynamics code. The parallel algorithm consists of a variety of components which are combined in order to produce a state of the art computational capability, capable of solving large thermal radiation transport problems using Blue-Oak, the 3 Tera-Flop MPP (massive parallel processors) computing facility at AWE (United Kingdom). Particular aspects of the parallel algorithm are described together with examples of the performance on some challenging applications. (author)

  11. Single-Shot MR Spectroscopic Imaging with Partial Parallel Imaging

    Science.gov (United States)

    Posse, Stefan; Otazo, Ricardo; Tsai, Shang-Yueh; Yoshimoto, Akio Ernesto; Lin, Fa-Hsuan

    2010-01-01

    An MR spectroscopic imaging (MRSI) pulse sequence based on Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI) is introduced that measures 2-dimensional metabolite maps in a single excitation. Echo-planar spatial-spectral encoding was combined with interleaved phase encoding and parallel imaging using SENSE to reconstruct absorption mode spectra. The symmetrical k-space trajectory compensates phase errors due to convolution of spatial and spectral encoding. Single-shot MRSI at short TE was evaluated in phantoms and in vivo on a 3 T whole body scanner equipped with 12-channel array coil. Four-step interleaved phase encoding and 4-fold SENSE acceleration were used to encode a 16×16 spatial matrix with 390 Hz spectral width. Comparison with conventional PEPSI and PEPSI with 4-fold SENSE acceleration demonstrated comparable sensitivity per unit time when taking into account g-factor related noise increases and differences in sampling efficiency. LCModel fitting enabled quantification of Inositol, Choline, Creatine and NAA in vivo with concentration values in the ranges measured with conventional PEPSI and SENSE-accelerated PEPSI. Cramer-Rao lower bounds were comparable to those obtained with conventional SENSE-accelerated PEPSI at the same voxel size and measurement time. This single-shot MRSI method is therefore suitable for applications that require high temporal resolution to monitor temporal dynamics or to reduce sensitivity to tissue movement. PMID:19097245

  12. Impact of multiple-dose versus single-dose inhaler devices on COPD patients’ persistence with long-acting β2-agonists: a dispensing database analysis

    Science.gov (United States)

    van Boven, Job FM; van Raaij, Joost J; van der Galiën, Ruben; Postma, Maarten J; van der Molen, Thys; Dekhuijzen, PN Richard; Vegter, Stefan

    2014-01-01

    Background: With a growing availability of different devices and types of medication, additional evidence is required to assist clinicians in prescribing the optimal medication in relation to chronic obstructive pulmonary disease (COPD) patients’ persistence with long-acting β2-agonists (LABAs). Aims: To assess the impact of the type of inhaler device (multiple-dose versus single-dose inhalers) on 1-year persistence and switching patterns with LABAs. Methods: A retrospective observational cohort study was performed comparing a cohort of patients initiating multiple-dose inhalers and a cohort initiating single-dose inhalers. The study population consisted of long-acting bronchodilator naive COPD patients, initiating inhalation therapy with mono-LABAs (formoterol, indacaterol or salmeterol). Analyses were performed using pharmacy dispensing data from 1994 to 2012, obtained from the IADB.nl database. Study outcomes were 1-year persistence and switching patterns. Results were adjusted for initial prescriber, initial medication, dosing regimen and relevant comorbidities. Results: In all, 575 patients initiating LABAs were included in the final study cohort. Among them, 475 (83%) initiated a multiple-dose inhaler and 100 (17%) a single-dose inhaler. Further, 269 (47%) initiated formoterol, 9 (2%) indacaterol and 297 (52%) salmeterol. There was no significant difference in persistence between users of multiple-dose or single-dose inhalers (hazard ratio: 0.98, 95% confidence interval: 0.76–1.26, P=0.99). Over 80% re-started or switched medication. Conclusions: There seems no impact of inhaler device (multiple-dose versus single-dose inhalers) on COPD patients’ persistence with LABAs. Over 80% of patients who initially seemed to discontinue LABAs, re-started their initial medication or switched inhalers or medication within 1 year. PMID:25274453

  13. A Lightweight RFID Grouping-Proof Protocol Based on Parallel Mode and DHCP Mechanism

    Directory of Open Access Journals (Sweden)

    Zhicai Shi

    2017-07-01

    Full Text Available A Radio Frequency Identification (RFID grouping-proof protocol is to generate an evidence of the simultaneous existence of a group of tags and it has been applied to many different fields. For current grouping-proof protocols, there still exist some flaws such as low grouping-proof efficiency, being vulnerable to trace attack and information leakage. To improve the secure performance and efficiency, we propose a lightweight RFID grouping-proof protocol based on parallel mode and DHCP (Dynamic Host Configuration Protocol mechanism. Our protocol involves multiple readers and multiple tag groups. During the grouping-proof period, one reader and one tag group are chosen by the verifier by means of DHCP mechanism. When only a part of the tags of the chosen group exist, the protocol can also give the evidence of their co-existence. Our protocol utilizes parallel communication mode between reader and tags so as to ensure its grouping-proof efficiency. It only uses Hash function to complete the mutual authentication among verifier, readers and tags. It can preserve the privacy of the RFID system and resist the attacks such as eavesdropping, replay, trace and impersonation. Therefore the protocol is secure, flexible and efficient. It only uses some lightweight operations such as Hash function and a pseudorandom number generator. Therefore it is very suitable to some low-cost RFID systems.

  14. Bistatic scattering from a three-dimensional object above a two-dimensional randomly rough surface modeled with the parallel FDTD approach.

    Science.gov (United States)

    Guo, L-X; Li, J; Zeng, H

    2009-11-01

    We present an investigation of the electromagnetic scattering from a three-dimensional (3-D) object above a two-dimensional (2-D) randomly rough surface. A Message Passing Interface-based parallel finite-difference time-domain (FDTD) approach is used, and the uniaxial perfectly matched layer (UPML) medium is adopted for truncation of the FDTD lattices, in which the finite-difference equations can be used for the total computation domain by properly choosing the uniaxial parameters. This makes the parallel FDTD algorithm easier to implement. The parallel performance with different number of processors is illustrated for one rough surface realization and shows that the computation time of our parallel FDTD algorithm is dramatically reduced relative to a single-processor implementation. Finally, the composite scattering coefficients versus scattered and azimuthal angle are presented and analyzed for different conditions, including the surface roughness, the dielectric constants, the polarization, and the size of the 3-D object.

  15. Evidence for single-dose protection by the bivalent HPV vaccine-Review of the Costa Rica HPV vaccine trial and future research studies.

    Science.gov (United States)

    Kreimer, Aimée R; Herrero, Rolando; Sampson, Joshua N; Porras, Carolina; Lowy, Douglas R; Schiller, John T; Schiffman, Mark; Rodriguez, Ana Cecilia; Chanock, Stephen; Jimenez, Silvia; Schussler, John; Gail, Mitchell H; Safaeian, Mahboobeh; Kemp, Troy J; Cortes, Bernal; Pinto, Ligia A; Hildesheim, Allan; Gonzalez, Paula

    2018-01-20

    The Costa Rica Vaccine Trial (CVT), a phase III randomized clinical trial, provided the initial data that one dose of the HPV vaccine could provide durable protection against HPV infection. Although the study design was to administer all participants three doses of HPV or control vaccine, 20% of women did not receive the three-dose regimens, mostly due to involuntary reasons unrelated to vaccination. In 2011, we reported that a single dose of the bivalent HPV vaccine could be as efficacious as three doses of the vaccine using the endpoint of persistent HPV infection accumulated over the first four years of the trial; findings independently confirmed in the GSK-sponsored PATRICIA trial. Antibody levels after one dose, although lower than levels elicited by three doses, were 9-times higher than levels elicited by natural infection. Importantly, levels remained essentially constant over at least seven years, suggesting that the observed protection provided by a single dose might be durable. Much work has been done to assure these non-randomized findings are valid. Yet, the group of recipients who received one dose of the bivalent HPV vaccine in the CVT and PATRICIA trials was small and not randomly selected nor blinded to the number of doses received. The next phase of research is to conduct a formal randomized, controlled trial to evaluate the protection afforded by a single dose of HPV vaccine. Complementary studies are in progress to bridge our findings to other populations, and to further document the long-term durability of antibody response following a single dose. Published by Elsevier Ltd.

  16. Comparison of scatter doses from a multislice and a single slice CT scanner

    International Nuclear Information System (INIS)

    Burrage, J. W.; Causer, D. A.

    2006-01-01

    During shielding calculations for a new multislice CT (MSCT) scanner it was found that the manufacturer's data indicated significantly higher external scatter doses than would be generated for a single slice CT (SSCT). Even allowing for increased beam width, the manufacturer's data indicated that the scatter dose per scan was higher by a factor of about 3 to 4. The magnitude of the discrepancy was contrary to expectations and also contrary to a statement by the UK ImPACT group, which indicated that when beam width is taken into account, the scatter doses should be similar. The matter was investigated by comparing scatter doses from an SSCT and an MSCT. Scatter measurements were performed at three points using a standard perspex CTDI phantom, and CT dose indices were also measured to compare scanner output. MSCT measurements were performed with a 40 mm wide beam, SSCT measurements with a 10 mm wide beam. A film badge survey was also performed after the installation of the MSCT scanner to assess the adequacy of lead shielding in the room. It was found that the scatter doses from the MSCT were lower than indicated by the manufacturer's data. MSCT scatter doses were approximately 4 times higher than those from the SSCT, consistent with expectations due to beam width differences. The CT dose indices were similar, and the film badge survey indicated that the existing shielding, which had been adequate for the SSCT, was also adequate for the MSCT

  17. Early-onset group B streptococcal disease following culture-based screening in Japan: a single center study.

    Science.gov (United States)

    Miyata, Akane; Takahashi, Hironori; Kubo, Takahiko; Watanabe, Noriyoshi; Tsukamoto, Keiko; Ito, Yushi; Sago, Haruhiko

    2012-08-01

    We investigated trends in early-onset group B streptococcal disease (EOD) after the introduction of culture-based screening in Japan. A retrospective cohort study examined EOD trends in 9506 pregnancies and 10 715 neonates at our center from 2002 to 2009. EOD occurred in four neonates (4/7332: 0.55/1000 live births). The EOD incidence among infants born to women positive for GBS by screening was 0.90 cases per 1000 live births (1/1107). In contrast, the EOD incidence among infants negative by GBS screening was 0.48 cases per 1000 live births (3/6225). Thus, of the four affected neonates, three had mothers who tested negative on antepartum GBS screening. Two neonates had symptoms of infection during labor and intrapartum antibiotic agents were administered. The other two neonates received no antibiotics because deliveries were uneventful and they were negative on GBS screening. The incidence of EOD is 0.90 cases per 1000 live births among GBS-positive women and 0.48 cases per 1000 live births among GBS-negative women. The results of our study implied that EOD can develop regardless of GBS screening and intrapartum clinical course, although the method of sample collection, indications for antibiotic prophylaxis, and the antibiotics regimen should be considered. © 2012 The Authors. Journal of Obstetrics and Gynaecology Research © 2012 Japan Society of Obstetrics and Gynecology.

  18. Characterization of the disposition of fostamatinib in Japanese subjects including pharmacokinetic assessment in dry blood spots: results from two phase I clinical studies.

    Science.gov (United States)

    Martin, Paul; Cheung, S Y Amy; Yen, Mark; Han, David; Gillen, Michael

    2016-01-01

    The aims of the present study were to characterize the pharmacokinetics of fostamatinib in two phase I studies in healthy Japanese subjects after single- and multiple-dose administration, and to evaluate the utility of dried blood spot (DBS) sampling. In study A, 40 Japanese and 16 white subjects were randomized in a double-blind parallel group study consisting of seven cohorts, which received either placebo or a fostamatinib dose between 50 and 200 mg after single and multiple dosing. Pharmacokinetics of R406 (active metabolite of fostamatinib) in plasma and urine was assessed, and safety was intensively monitored. Study B was an open-label study that assessed fostamatinib 100 and 200 mg in 24 Japanese subjects. In addition to plasma and urine sampling (as for study A), pharmacokinetics was also assessed in blood. Mean maximum plasma concentration (C max) and area under total plasma concentration–time curve (AUC) increased with increasing dose in Japanese subjects. Steady state was achieved in 5–7 days for all doses. C max and AUC were both higher in Japanese subjects administered a 150-mg single dose than in white subjects. This difference was maintained for steady state exposure by day 10. Overall, R406 blood concentrations were consistent and ∼2.5-fold higher than in plasma. Minimal (blood cells, and DBS sampling was a useful method for assessing R406 pharmacokinetics.

  19. Analysis and design of a parallel-connected single active bridge DC-DC converter for high-power wind farm applications

    DEFF Research Database (Denmark)

    Park, Kiwoo; Chen, Zhe

    2013-01-01

    This paper presents a parallel-connected Single Active Bridge (SAB) dc-dc converter for high-power applications. Paralleling lower-power converters can lower the current rating of each modular converter and interleaving the outputs can significantly reduce the magnitudes of input and output curre...

  20. Comparison of two dose regimens of ibuprofen for the closure of patent ductus arteriosus in preterm newborns.

    Science.gov (United States)

    Dornelles, Laura Vargas; Corso, Andréa Lúcia; Silveira, Rita de Cássia; Procianoy, Renato Soibelmann

    2016-01-01

    To compare the efficacy of intravenous ibuprofen at high (20-10-10mg/kg/dose) and low doses (10-5-5mg/kg/dose) the closure of patent ductus arteriosus in preterm newborns. A cohort study with historical control of newborns that received high- and low-dose intravenous ibuprofen, from 2010 to 2013 in a neonatal intensive care unit, for closure of the patent ductus arteriosus, documented by echocardiography. Secondary outcomes included the number of ibuprofen cycles, incidence of bronchopulmonary dysplasia, necrotizing enterocolitis, changes in renal function, and death. Seventy-seven patients received three doses of ibuprofen for the treatment of patent ductus arteriosus, with 33 receiving high-dose and 44 low-dose therapy. The ductus closed after the first cycle in 25 (56.8%) low-dose patients and in 17 (51.5%) high-dose patients (p>0.99). Sixteen patients received a second cycle of ibuprofen, and the ductus closed in 50% after low-dose and in 60% after high-dose therapy (p>0.99). Seven patients required surgery for ductus closure, 13.6% in the low-dose group and 3% in the high-dose group (p=0.22). Thirty-nine patients developed bronchopulmonary dysplasia, 50% in the low-dose group and 51.5% in the high-dose group (p>0.99). Twenty-two (50%) low-dose patients died vs. 15 (45.5%) high-dose patients (p=0.86). There was no difference in closure of the ductus arteriosus or occurrence of adverse effects between the two dose regimens. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  1. Attentional Selection of Feature Conjunctions Is Accomplished by Parallel and Independent Selection of Single Features.

    Science.gov (United States)

    Andersen, Søren K; Müller, Matthias M; Hillyard, Steven A

    2015-07-08

    Experiments that study feature-based attention have often examined situations in which selection is based on a single feature (e.g., the color red). However, in more complex situations relevant stimuli may not be set apart from other stimuli by a single defining property but by a specific combination of features. Here, we examined sustained attentional selection of stimuli defined by conjunctions of color and orientation. Human observers attended to one out of four concurrently presented superimposed fields of randomly moving horizontal or vertical bars of red or blue color to detect brief intervals of coherent motion. Selective stimulus processing in early visual cortex was assessed by recordings of steady-state visual evoked potentials (SSVEPs) elicited by each of the flickering fields of stimuli. We directly contrasted attentional selection of single features and feature conjunctions and found that SSVEP amplitudes on conditions in which selection was based on a single feature only (color or orientation) exactly predicted the magnitude of attentional enhancement of SSVEPs when attending to a conjunction of both features. Furthermore, enhanced SSVEP amplitudes elicited by attended stimuli were accompanied by equivalent reductions of SSVEP amplitudes elicited by unattended stimuli in all cases. We conclude that attentional selection of a feature-conjunction stimulus is accomplished by the parallel and independent facilitation of its constituent feature dimensions in early visual cortex. The ability to perceive the world is limited by the brain's processing capacity. Attention affords adaptive behavior by selectively prioritizing processing of relevant stimuli based on their features (location, color, orientation, etc.). We found that attentional mechanisms for selection of different features belonging to the same object operate independently and in parallel: concurrent attentional selection of two stimulus features is simply the sum of attending to each of those

  2. Systematic approach for deriving feasible mappings of parallel algorithms to parallel computing platforms

    NARCIS (Netherlands)

    Arkin, Ethem; Tekinerdogan, Bedir; Imre, Kayhan M.

    2017-01-01

    The need for high-performance computing together with the increasing trend from single processor to parallel computer architectures has leveraged the adoption of parallel computing. To benefit from parallel computing power, usually parallel algorithms are defined that can be mapped and executed

  3. Low-dose cyclophosphamide administered as daily or single dose enhances the antitumor effects of a therapeutic HPV vaccine

    Science.gov (United States)

    Peng, Shiwen; Lyford-Pike, Sofia; Akpeng, Belinda; Wu, Annie; Hung, Chien-Fu; Hannaman, Drew; Saunders, John R.; Wu, T.-C.

    2012-01-01

    Although therapeutic HPV vaccines are able to elicit systemic HPV-specific immunity, clinical responses have not always correlated with levels of vaccine-induced CD8+ T cells in human clinical trials. This observed discrepancy may be attributable to an immunosuppressive tumor microenvironment in which the CD8+ T cells are recruited. Regulatory T cells (Tregs) are cells that can dampen cytotoxic CD8+ T-cell function. Cyclophosphamide (CTX) is a systemic chemotherapeutic agent, which can eradicate immune cells, including inhibitory Tregs. The optimal dose and schedule of CTX administration in combination with immunotherapy to eliminate the Treg population without adversely affecting vaccine-induced T-cell responses is unknown. Therefore, we investigated various dosing and administration schedules of CTX in combination with a therapeutic HPV vaccine in a preclinical tumor model. HPV tumor-bearing mice received either a single preconditioning dose or a daily dose of CTX in combination with the pNGVL4a-CRT/E7(detox) DNA vaccine. Both single and daily dosing of CTX in combination with vaccine had a synergistic anti-tumor effect as compared to monotherapy alone. The potent antitumor responses were attributed to the reduction in Treg frequency and increased infiltration of HPV16 E7-specific CD8+ T cells, which led to higher ratios of CD8+/Treg and CD8+/CD11b+Gr-1+ myeloid-derived suppressor cells (MDSCs). There was an observed trend toward decreased vaccine-induced CD8+ T-cell frequency with daily dosing of CTX. We recommend a single, preconditioning dose of CTX prior to vaccination due to its efficacy, ease of administration, and reduced cumulative adverse effect on vaccine-induced T cells. PMID:23011589

  4. Mobilization and collection of CD34+ cells for autologous transplantation of peripheral blood hematopoietic progenitor cells in children: analysis of two different granulocyte-colony stimulating factor doses

    Directory of Open Access Journals (Sweden)

    Kátia Aparecida de Brito Eid

    2015-06-01

    Full Text Available Introduction: The use of peripheral hematopoietic progenitor cells (HPCs is the cell choice in autologous transplantation. The classic dose of granulocyte-colony stimulating factor (G- CSF for mobilization is a single daily dose of 10 µg/kg of patient body weight. There is a theory that higher doses of granulocyte-colony stimulating factor applied twice daily could increase the number of CD34+ cells collected in fewer leukapheresis procedures. Objective: The aim of this study was to compare a fractionated dose of 15 µg G-CSF/kg of body weight and the conventional dose of granulocyte-colony stimulating factor in respect to the number of leukapheresis procedures required to achieve a minimum collection of 3 × 106 CD34+ cells/kg body weight. Methods: Patients were divided into two groups: Group 10 - patients who received a single daily dose of 10 µg G-CSF/kg body weight and Group 15 - patients who received a fractioned dose of 15 µg G-CSF/kg body weight daily. The leukapheresis procedure was carried out in an automated cell separator. The autologous transplantation was carried out when a minimum number of 3 × 106 CD34+ cells/kg body weight was achieved. Results: Group 10 comprised 39 patients and Group 15 comprised 26 patients. A total of 146 apheresis procedures were performed: 110 (75.3% for Group 10 and 36 (24.7% for Group 15. For Group 10, a median of three (range: 1-7 leukapheresis procedures and a mean of 8.89 × 106 CD34+ cells/kg body weight (±9.59 were collected whereas for Group 15 the corresponding values were one (range: 1-3 and 5.29 × 106 cells/kg body weight (±4.95. A statistically significant difference was found in relation to the number of apheresis procedures (p-value <0.0001. Conclusions: To collect a minimum target of 3 × 106 CD34+ cells/kg body weight, the administration of a fractionated dose of 15 µg G-CSF/kg body weight significantly decreased the number of leukapheresis procedures performed.

  5. Effects of two doses of anti-T lymphocyte globulin-Fresenius given after full-match sibling stem cell transplantation in acute myeloblastic leukemia patients who underwent myeloablative fludarabine/busulfan conditioning.

    Science.gov (United States)

    Boga, Can; Yeral, Mahmut; Gereklioglu, Ciğdem; Asma, Suheyl; Maytalman, Erkan; Aytan, Pelin; Kozanoglu, Ilknur; Sariturk, Cagla; Ozdogu, Hakan

    2018-02-20

    Anti-T lymphocyte globulin Fresenius (rATG-F; ATG-Fresenius) and antithymocyte globulin (thymoglobulin), which are included in transplant protocols, are used to reduce the risk of chronic graft-versus-host disease (cGVHD) or suppress allograft rejection. Available clinical studies have been conducted in heterogenous patient populations and with different administration protocols including stem cell sources. Additionally, the pharmacokinetics of ATG is variable, and the clinically effective dose of rATG-F, in particular, is not exactly known. The aim of the study was to investigate the clinical outcomes of acute myeloid leukemia (AML) patients who underwent hemopoietic peripheral stem cell transplantation from full-matched sibling donors and given two different doses of r-ATG-F. This was a single-center, retrospective chart review conducted between July 2005 and July 2016. Sixty-nine consecutive AML patients who underwent transplant with fludarabine- and busulfan-based conditioning were included in the study. Patients in Group 1 received 15 mg/kg body weight rATG-F to 2013 (n = 46), and Group 2 received 30 mg/kg of rATG-F dose begining in 2013 to reduce to cGVHD (n = 23). Cyclosporine and methotrexate were used to treat acute GVHD (aGVHD) prophylaxis. Outcome parameters were compared between the groups. Although the recommended dose r-ATG-F had led to a decrease in the cumulative incidence of cGVHD (27 [58.7%] vs. 8 [34.8%]; p = .03), it also increased the infection rate at 1 year (3 [6.5%] vs. 4 [17.4%]; p = .02). The two groups were similar in terms of engraftment time, aGVHD, relapse, nonrelapse mortality, and rATG-F-related toxicity. A Cox regression model revealed that aGVHD III-IV was associated with increased nonrelapse mortality at 1 year (hazard ratio = 18.2; 95% confidence interval, 1.667-199.255; p = <.02). No patients developed rATG-F-related severe adverse events (Common Terminology Criteria grade 4 or 5). Dose difference of

  6. Transfer of single dose of intravitreal injection of ranibizumab and bevacizumab into milk of sheep

    Directory of Open Access Journals (Sweden)

    Tugba Cakmak Argun

    2017-07-01

    Full Text Available AIM: To investigate whether single-dose intravitreal injections of bevacizumab and ranibizumab transfer into milk. METHODS: This study included lactating 12 sheep and a single 3-month old suckling lamb of each sheep. Two groups consisting of 6 sheep and their lambs were constituted; the ranibizumab group and the bevacizumab group before the administration of intravitreal injections, blood and milk samples were obtained from all sheep and, following the injections, blood and milk samples of all sheep and blood samples of all lambs were collected at regular time points. Serum and milk concentrations of bevacizumab and ranibizumab were measured using an enzyme-linked immunosorbent assay (ELISA kit. The limit of determination was 0.9 ng/mL for bevacizumab and 0.62 ng/mL for ranibizumab. RESULTS: At 6h after intravitreal injections, bevacizumab concentration was above the limit of determination in the blood of all sheep. At 3wk, when the study was terminated, bevacizumab concentrations were high in 4 sheep. Even though bevacizumab concentrations in milk showed fluctuations, the drug transferred into the milk of all sheep at detectable concentrations. Ranibizumab drug concentrations in the blood and milk of sheep and those in the blood of lambs were below the limit of determination by the ELISA kit. CONCLUSION: This sheep model study demonstrate that intravitreal injection of ranibizumab, which did not transfer into the milk of sheep and suckling lambs, is safer than bevacizumab during lactation period.

  7. Staggering the dose of sugammadex lowers risks for severe emergence cough: a randomized control trial.

    Science.gov (United States)

    P S, Loh; Miskan, M M; Y Z, Chin; Zaki, R A

    2017-10-11

    Cough on emergence has been reported as a common adverse reaction with sugammadex reversal. We investigated if staggering the dose of sugammadex will reduce emergence cough in a single-center, randomized, double-blinded study. A hundred and twenty ASA 1-3 adults were randomly reversed with 1 mg/kg sugammadex prior to extubation followed by another 1 mg/kg immediately after extubation (staggered group), single dose of 2 mg/kg sugammadex (single bolus group) or neostigmine 0.02 mg/kg with glycopyrrolate (neostigmine group). We found 70% of patients (n = 28) reversed with single boluses of sugammadex had Grade 3 emergence cough compared to 12.5% (n = 5) in the staggered sugammadex group and 17.5% (n = 7) in the neostigmine group (p sugammadex group (n = 14, 35%, p = 0.005). On the other hand, staggering sugammadex lowered risks of developing severe cough (RR 0.2, p sugammadex group and control given neostigmine. In terms of timing, there was no delay in time taken from discontinuing anesthetic agents to reversal and extubation if sugammadex was staggered (emergence time 6.0 ± 3.2 s, p = 0.625 and reversal time 6.5 ± 3.5, p = 0.809). Staggering the dose of sugammadex for reversal will effectively decrease common emergence and early postoperative complications. ANZCTR Number ACTRN12616000116426 . Retrospectively registered on 2nd February 2016.

  8. Atrial Fibrillation Following Surgical Management of Ischemic Heart Disease; One Year, Single Center, Single Surgeon Results

    Directory of Open Access Journals (Sweden)

    Ahmet Barış Durukan

    2012-08-01

    Full Text Available Introduction: Postoperative atrial fibrillation is the most common arrhythmia following bypasssurgery with significant morbidity, mortality and increased healthcare costs. The aim of this studyis to determine the incidence and timing of atrial fibrillation, identify the risk factors coveringpreoperative and intraoperative periods, evaluate rate of return to sinus rhythm by disharge, andexplore the impact on postoperative outcomes in a large group of patients operated in a singlecenter by a single surgeon.Patients and Methods: Between January 2011 and January 2012, 418 patients on preoperativesinus rhythm were operated for ischemic heart disease and associated complications (left ventricleaneurysm repair and ischemic mitral insufficiency in a single center, by a single surgeon.The preoperative, intraoperative and postoperative variables were studied.Results: The mean age of the patients were 61.92 ± 10.05, and 77.5% were male. Atrial fibrillationdeveloped in 68 (16.3% patients. The incidence peaked at second day. Patients with atrialfibrillation were older (p< 0.001. Gender, preoperative comorbidities, ejection fraction, left atrialdiameter, preoperative beta-blocker use, leukocyte count, type of operation and intraoperativevariables did not affect its occurence. Intensive care unit and hospital length of stay were longer(p< 0.05. 95.5% (n= 65 of patients were in normal sinus rhythm at discharge.Conclusion: Postoperative atrial fibrillation is a popular subject with unknowns and controversialresults which may lead to wrong interpretations. We believe that every center has its own risk factors related with the population of that region. Discussion will last, but simple precautions and close monitoring will help to minimizeadverse outcomes.

  9. Single dose oral ketoprofen and dexketoprofen for acute postoperative pain in adults.

    Science.gov (United States)

    Barden, Jodie; Derry, Sheena; McQuay, Henry J; Moore, R Andrew

    2009-10-07

    Ketoprofen is a non-selective non-steroidal anti-inflammatory drug (NSAID) used to treat acute and chronic painful conditions. Dexketoprofen is the (S)-enantiomer, which is believed to confer analgesia. Theoretically dexketoprofen is expected to provide equivalent analgesia to ketoprofen at half the dose, with a consequent reduction in gastrointestinal adverse events. To assess efficacy, duration of action, and associated adverse events of single dose oral ketoprofen and dexketoprofen in acute postoperative pain in adults. We searched Cochrane CENTRAL, MEDLINE, EMBASE and the Oxford Pain Relief Database for studies to August 2009. Randomised, double blind, placebo-controlled trials of single dose orally administered ketoprofen and dexketoprofen in adults with moderate to severe acute postoperative pain. Two review authors independently assessed trial quality and extracted data. Pain relief or pain intensity data were extracted and converted into the dichotomous outcome of number of participants with at least 50% pain relief over 4 to 6 hours, from which relative risk and number-needed-to-treat-to-benefit (NNT) were calculated. Numbers of participants using rescue medication over specified time periods, and time to use of rescue medication, were sought as additional measures of efficacy. Information on adverse events and withdrawals was collected. Fourteen studies compared ketoprofen (968 participants) at mainly 25 mg and 50 mg with placebo (520 participants). Seven studies compared dexketoprofen (681 participants) at mainly 10 mg to 25 mg with placebo (289 participants). Studies were of adequate reporting quality, and participants had pain following dental, orthopaedic, obstetric, gynaecological and general surgery. There was considerable clinical heterogeneity between studies in dental and other types of surgery, particularly bunionectomy, which limited analysis.Ketoprofen at doses between 12.5 mg and 100 mg produced NNTs for at least 50% pain relief over 4 to 6

  10. Parallel computations

    CERN Document Server

    1982-01-01

    Parallel Computations focuses on parallel computation, with emphasis on algorithms used in a variety of numerical and physical applications and for many different types of parallel computers. Topics covered range from vectorization of fast Fourier transforms (FFTs) and of the incomplete Cholesky conjugate gradient (ICCG) algorithm on the Cray-1 to calculation of table lookups and piecewise functions. Single tridiagonal linear systems and vectorized computation of reactive flow are also discussed.Comprised of 13 chapters, this volume begins by classifying parallel computers and describing techn

  11. Implementation research: reactive mass vaccination with single-dose oral cholera vaccine, Zambia.

    Science.gov (United States)

    Poncin, Marc; Zulu, Gideon; Voute, Caroline; Ferreras, Eva; Muleya, Clara Mbwili; Malama, Kennedy; Pezzoli, Lorenzo; Mufunda, Jacob; Robert, Hugues; Uzzeni, Florent; Luquero, Francisco J; Chizema, Elizabeth; Ciglenecki, Iza

    2018-02-01

    To describe the implementation and feasibility of an innovative mass vaccination strategy - based on single-dose oral cholera vaccine - to curb a cholera epidemic in a large urban setting. In April 2016, in the early stages of a cholera outbreak in Lusaka, Zambia, the health ministry collaborated with Médecins Sans Frontières and the World Health Organization in organizing a mass vaccination campaign, based on single-dose oral cholera vaccine. Over a period of 17 days, partners mobilized 1700 health ministry staff and community volunteers for community sensitization, social mobilization and vaccination activities in 10 townships. On each day, doses of vaccine were delivered to vaccination sites and administrative coverage was estimated. Overall, vaccination teams administered 424 100 doses of vaccine to an estimated target population of 578 043, resulting in an estimated administrative coverage of 73.4%. After the campaign, few cholera cases were reported and there was no evidence of the disease spreading within the vaccinated areas. The total cost of the campaign - 2.31 United States dollars (US$) per dose - included the relatively low cost of local delivery - US$ 0.41 per dose. We found that an early and large-scale targeted reactive campaign using a single-dose oral vaccine, organized in response to a cholera epidemic within a large city, to be feasible and appeared effective. While cholera vaccines remain in short supply, the maximization of the number of vaccines in response to a cholera epidemic, by the use of just one dose per member of an at-risk community, should be considered.

  12. Relative bioavailability of generic and branded 250-mg and 500-mg oral chlorphenesin carbamate tablets in healthy Korean volunteers: a single-dose, randomized-sequence, open-label, two-period crossover trial.

    Science.gov (United States)

    Yu, Ji-young; Song, Hyun Ho; Kim, Bo Gyeom; Park, Hyeon Ju; Choi, Kwang Sik; Kwon, Young Ee

    2009-11-01

    Chlorphenesin carbamate is a skeletal muscle relaxant approved in Korea for use in the treatment of pain and discomfort related to skeletal muscle trauma and inflammation. The aim of this study was to assess the bioequivalence of a generic formulation of chlorphenesin carbamate at doses of 250 and 500 mg and 2 branded formulations of the same doses in healthy Korean adults. This single-dose, randomized-sequence, open-label, 2-period crossover study was conducted in healthy Korean male and female volunteers. Subjects were assigned to receive, in a randomized sequence, a single dose of the generic (test) and branded (reference) formulations of chlorphenesin carbamate at a dose of 250 or 500 mg. Blood samples were drawn at 0, 0.33, 0.67, 1, 1.5, 2, 3, 4, 6, 9, 12, and 15 hours after administration. Pharmacokinetic properties (C(max), T(max), AUC(0-t) AUC(0-infinity), t(1/2), and ke) were determined using HPLC. The formulations were to be considered bioequivalent if the 90% CIs of the treatment ratios of the geometric means of C(max) and AUC(0-t) were within a predetermined range of log 0.80 to log 1.25 based on regulatory criteria. Tolerability was assessed by monitoring for adverse events (AEs) on physical examination and/or e-mail and personal interview at the beginning and end of each study period. Twenty-eight subjects (22 men, 6 women) received chlorphenesin carbamate at the 250-mg dose, and 24 male subjects received the 500-mg dose. The mean (SD) ages of the subjects were 24.0 (2.6) and 24.0 (1.9) years in the 250- and 500-mg groups, respectively. No significant differences were found between the test and reference formulations (90% CIs: C(max), 1.0048-1.1153 with the 250-mg dose and 0.9630-1.1189 with the 500-mg dose; AUC(0-t), 0.9882-1.0546 and 0.9842-1.0578, respectively). No clinically significant AEs (upper gastric pain, abdominal bloating, pyrexia, edema, nausea, heartburn, constipation, headache, dizziness, drowsiness, or fatigue) were reported throughout

  13. Study of the fluorescence blinking behavior of single F2 color centers in LiF crystal

    International Nuclear Information System (INIS)

    Boichenko, S V; Koenig, K; Zilov, S A; Dresvianskiy, V P; Rakevich, A L; Kuznetsov, A V; Bartul, A V; Martynovich, E F; Voitovich, A P

    2014-01-01

    Using confocal fluorescence microscopy technique, we observed experimentally the luminescence of single F 2 color centers in LiF crystal. It is disclosed that the fluorescence shows blinking behavior. It is shown that this phenomenon is caused by the F 2 center reorientation occurring during the experiment. The ratio of luminescence intensities of differently oriented centers is assessed theoretically for two different experiment configurations. The calculated ratios are in fine agreement with experimental result

  14. Observational Study to Assess the Therapeutic Value of Four Ovarian Hyperstimulation Protocols in IVF After Pituitary Suppression with GnRH Antagonists in Normally Responding Women

    OpenAIRE

    Ana, Monzó; Vicente, Montañana; María, Rubio José; Trinidad, García-Gimeno; Alberto, Romeu

    2011-01-01

    Objective To compare the clinical results of four different protocols of COH for IVF-ICSI in normovulatory women, using in all cases pituitary suppression with GnRH antagonists. Materials/methods A single center, open label, parallel-controlled, prospective, post-authorization study under the approved conditions for use where 305 normal responders women who were candidates to COH were assigned to r-FSH + hp-hMG (n = 51, Group I), hp-hMG (n = 61, Group II), fixed-dose r-FSH (n = 118, Group III...

  15. Single-dose and fractionated irradiation of four human lung cancer cell lines in vitro

    International Nuclear Information System (INIS)

    Brodin, O.; Lennartsson, L.; Nilsson, S.

    1991-01-01

    Four established human lung cancer cell lines were exposed to single-dose irradiation. The survival curves of 2 small cell lung carcinomas (SCLC) were characterized by a limited capacity for repair with small and moderate shoulders with extrapolation numbers (n) of 1.05 and 1.60 respectively. Two non-small cell lung carcinoma (NSCLC) cell lines, one squamous cell (SQCLC) and one large cell (LCLC) had large shoulders with n-values of 73 and 15 respectively. The radiosensitivity when measured as D 0 did not, however, differ as much from cell line to cell line, with values from 1.22 to 1.65. The surviving fraction after 2 Gy (SF2) was 0.24 and 0.42 respectively in the SCLC cell lines and 0.90 and 0.88 respectively in the NSCLC cell lines. Fractionated irradiation delivered according to 3 different schedules was also investigated. All the schedules delivered a total dose of 10 Gy in 5 days and were applied in 1, 2 and 5 Gy dose fractions respectively. Survival followed the pattern found after single-dose irradiation; it was lowest in the SCLC cell line with the lowest SF and highest in the two NSCLC cell lines. In the SCLC cell lines all schedules were approximately equally efficient. In the LCLC and in the SQCLC cell lines, the 5 Gy schedule killed more cells than the 1 and 2 Gy schedules. The results indicate that the size of the shoulder of the survival curve is essential when choosing the most tumoricidal fractionation schedule. (orig.)

  16. Parallel and distributed processing in two SGBDS: A case study

    OpenAIRE

    Francisco Javier Moreno; Nataly Castrillón Charari; Camilo Taborda Zuluaga

    2017-01-01

    Context: One of the strategies for managing large volumes of data is distributed and parallel computing. Among the tools that allow applying these characteristics are some Data Base Management Systems (DBMS), such as Oracle, DB2, and SQL Server. Method: In this paper we present a case study where we evaluate the performance of an SQL query in two of these DBMS. The evaluation is done through various forms of data distribution in a computer network with different degrees of parallelism. ...

  17. [Single intravenous tranexamic acid dose to reduce blood loss in primary total knee replacement].

    Science.gov (United States)

    Sanz-Reig, J; Parra Ruiz, B; Ferrández Martínez, J; Martínez López, J F

    2016-01-01

    To evaluate the effectiveness and safety of a single intravenous dose of tranexamic acid in order to reduce blood loss in total knee replacement. Prospective observational study of the administration of tranexamic acid in patients undergoing primary total knee arthroplasty from November 2013 to February 2015, in which an autologous blood recovery system was used. The study included 98 patients, distributed into two groups of 49 patients according to whether or not they received intravenous tranexamic acid. The primary endpoint was the number of patients requiring autologous transfusion from the recovery system autologous blood recovery system. No drop-outs were recorded during follow-up. There were no significant differences between groups as regards the preoperative and hospital variables. The mean preoperative haemoglobin and haematocrit at 24 and 48 hours postoperatively were similar in both groups. The average volume of bleeding in the autologous blood recovery system and estimated average blood loss was lower in patients who had been administered tranexamic acid, with significant differences. No patients in the group that was administered tranexamic acid required blood autotransfusion. The transfusion rate was zero in the two groups. No adverse events related to the administration of tranexamic acid were recorded. Intravenous administration of tranexamic acid, according to the described protocol, has presented a non-autotransfusion or allo-transfusion rate of 100%, with no increased incidence of thrombotic events. Thus, its use in this group of patients is recommended. The indication should be individualized, its use justified in the patient medical records, and informed consent is mandatory. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  18. SU-E-T-568: Neutron Dose Survey of a Compact Single Room Proton Machine

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y; Prusator, M; Islam, M; Johnson, D; Ahmad, S [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2015-06-15

    Purpose: To ensure acceptable radiation limits are maintained for those working at and near the machine during its operation, a comprehensive radiation survey was performed prior to the clinical release of Mevion S250 compact proton machine at Stephenson Oklahoma Cancer Center. Methods: The Mevion S250 proton therapy system consists of the following: a superconducting cyclotron to accelerate the proton particles, a passive double scattering system for beam shaping, and paired orthogonal x-ray imaging systems for patient setup and verification via a 6D robotic couch. All equipment is housed within a single vault of compact design. Two beam delivery applicators are available for patient treatment, offering field sizes of as great as 14 cm and 25 cm in diameter, respectively. Typical clinical dose rates are between 1 and 2 Gy/min with a fixed beam energy of 250 MeV. The large applicator (25 cm in diameter) was used in conjunction with a custom cut brass aperture to create a 20 cm x 20 cm field size at beam isocenter. A 30 cm − 30 cm − 35 cm high density plastic phantom was placed in the beam path to mimic the conditions creating patient scatter. Measurements integrated-ambient-neutron-dose-equivalence were made with a SWENDII detector. Gantry angles of 0, 90 and 180 degrees, with a maximum dose rate of 150 MU/min (for large applicator) and beam configuration of option 1 (range 25 cm and 20 cm modulation), were selected as testing conditions. At each point of interest, the highest reading was recorded at 30 cm from the barrier surface. Results: The highest neutron dose was estimated to be 0.085 mSv/year at the console area. Conclusion: All controlled areas are under 5 mSv/year and the uncontrolled areas are under 1 mSv/year. The radiation protection provided by the proton vault is of sufficient quality.

  19. Effect of single-dose low-level helium-neon laser irradiation on orthodontic pain: a split-mouth single-blind placebo-controlled randomized clinical trial.

    Science.gov (United States)

    Sobouti, Farhad; Khatami, Maziar; Chiniforush, Nasim; Rakhshan, Vahid; Shariati, Mahsa

    2015-01-01

    Pain is the most common complication of orthodontic treatment. Low-level laser therapy (LLLT) has been suggested as a new analgesic treatment free of the adverse effects of analgesic medications. However, it is not studied thoroughly, and the available studies are quite controversial. Moreover, helium neon (He-Ne) laser has not been assessed before. This split-mouth placebo-controlled randomized clinical trial was performed on 16 male and 14 female orthodontic patients requiring bilateral upper canine retraction. The study was performed at a private clinic in Sari, Iran, in 2014. It was single blind: patients, orthodontist, and personnel were blinded of the allocations, but the laser operator (periodontist) was not blinded. Once canine retractor was activated, a randomly selected maxillary quarter received a single dose of He-Ne laser irradiation (632.8 nm, 10 mw, 6 j/cm(2) density). The other quarter served as the placebo side, treated by the same device but powered off. In the first, second, fourth, and seventh days, blinded patients rated their pain sensed on each side at home using visual analog scale (VAS) questionnaires. There was no harm identified during or after the study. Pain changes were analyzed using two- and one-way repeated-measures ANOVA, Bonferroni, and t-test (α = 0.01, β > 0.99). This trial was not registered. It was self-funded by the authors. Sixteen males and 11 females remained in the study (aged 12-21). Average pain scores sensed in all 4 intervals on control and laser sides were 4.06 ± 2.85 and 2.35 ± 1.77, respectively (t-test P < 0.0001). One-way ANOVA showed significant pain declines over time, in each group (P < 0.0001). Two-way ANOVA showed significant effects for LLLT (P < 0.0001) and time (P = <0.0001). Single-dose He-Ne laser therapy might reduce orthodontic pain caused by retracting maxillary canines.

  20. Broadcasting a message in a parallel computer

    Science.gov (United States)

    Berg, Jeremy E [Rochester, MN; Faraj, Ahmad A [Rochester, MN

    2011-08-02

    Methods, systems, and products are disclosed for broadcasting a message in a parallel computer. The parallel computer includes a plurality of compute nodes connected together using a data communications network. The data communications network optimized for point to point data communications and is characterized by at least two dimensions. The compute nodes are organized into at least one operational group of compute nodes for collective parallel operations of the parallel computer. One compute node of the operational group assigned to be a logical root. Broadcasting a message in a parallel computer includes: establishing a Hamiltonian path along all of the compute nodes in at least one plane of the data communications network and in the operational group; and broadcasting, by the logical root to the remaining compute nodes, the logical root's message along the established Hamiltonian path.

  1. Parallelization of a three-dimensional whole core transport code DeCART

    Energy Technology Data Exchange (ETDEWEB)

    Jin Young, Cho; Han Gyu, Joo; Ha Yong, Kim; Moon-Hee, Chang [Korea Atomic Energy Research Institute, Yuseong-gu, Daejon (Korea, Republic of)

    2003-07-01

    Parallelization of the DeCART (deterministic core analysis based on ray tracing) code is presented that reduces the computational burden of the tremendous computing time and memory required in three-dimensional whole core transport calculations. The parallelization employs the concept of MPI grouping and the MPI/OpenMP mixed scheme as well. Since most of the computing time and memory are used in MOC (method of characteristics) and the multi-group CMFD (coarse mesh finite difference) calculation in DeCART, variables and subroutines related to these two modules are the primary targets for parallelization. Specifically, the ray tracing module was parallelized using a planar domain decomposition scheme and an angular domain decomposition scheme. The parallel performance of the DeCART code is evaluated by solving a rodded variation of the C5G7MOX three dimensional benchmark problem and a simplified three-dimensional SMART PWR core problem. In C5G7MOX problem with 24 CPUs, a speedup of maximum 21 is obtained on an IBM Regatta machine and 22 on a LINUX Cluster in the MOC kernel, which indicates good parallel performance of the DeCART code. In the simplified SMART problem, the memory requirement of about 11 GBytes in the single processor cases reduces to 940 Mbytes with 24 processors, which means that the DeCART code can now solve large core problems with affordable LINUX clusters. (authors)

  2. Single-dose intra-articular bupivacaine plus morphine versus bupivacaine alone after arthroscopic knee surgery: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Yang, Ye; Zeng, Chao; Wei, Jie; Li, Hui; Yang, Tuo; Deng, Zhen-Han; Li, Yu-Sheng; Yang, Tu-Bao; Lei, Guang-Hua

    2017-03-01

    The purpose of this meta-analysis was to compare the efficacy and safety of single-dose intra-articular bupivacaine plus morphine versus bupivacaine alone for pain management following arthroscopic knee surgery. A comprehensive literature search was conducted to identify randomized controlled trials that used single-dose intra-articular bupivacaine plus morphine and bupivacaine alone for post-operative pain, using MEDLINE (1966-2014), Cochrane Library and EMBASE databases. The weighted mean difference (WMD), relative risk (RR) and their corresponding 95 % confidence intervals (CIs) were calculated using RevMan statistical software. A total of twenty-nine trials (n = 1167) were included. The post-operative visual analog scale (VAS) pain score of the bupivacaine plus morphine group compared with the bupivacaine alone group was significantly lower (WMD -1.15, 95 % CI -1.67 to -0.63, p bupivacaine plus morphine was shown to be significantly better than bupivacaine alone at relieving post-operative pain after arthroscopic knee surgery without increasing the short-term side effects. Routine use of single-dose intra-articular bupivacaine plus morphine is an effective way for pain management after arthroscopic knee surgery. II.

  3. On radial flow between parallel disks

    International Nuclear Information System (INIS)

    Wee, A Y L; Gorin, A

    2015-01-01

    Approximate analytical solutions are presented for converging flow in between two parallel non rotating disks. The static pressure distribution and radial component of the velocity are developed by averaging the inertial term across the gap in between parallel disks. The predicted results from the first approximation are favourable to experimental results as well as results presented by other authors. The second approximation shows that as the fluid approaches the center, the velocity at the mid channel slows down which is due to the struggle between the inertial term and the flowrate. (paper)

  4. Critical groups vs. representative person: dose calculations due to predicted releases from USEXA

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, N.L.D., E-mail: nelson.luiz@ctmsp.mar.mil.br [Centro Tecnologico da Marinha (CTM/SP), Sao Paulo, SP (Brazil); Rochedo, E.R.R., E-mail: elainerochedo@gmail.com [Instituto de Radiprotecao e Dosimetria (lRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Mazzilli, B.P., E-mail: mazzilli@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The critical group cf Centro Experimental Aramar (CEA) site was previously defined based 00 the effluents releases to the environment resulting from the facilities already operational at CEA. In this work, effective doses are calculated to members of the critical group considering the predicted potential uranium releases from the Uranium Hexafluoride Production Plant (USEXA). Basically, this work studies the behavior of the resulting doses related to the type of habit data used in the analysis and two distinct situations are considered: (a) the utilization of average values obtained from official institutions (IBGE, IEA-SP, CNEN, IAEA) and from the literature; and (b) the utilization of the 95{sup tb} percentile of the values derived from distributions fit to the obtained habit data. The first option corresponds to the way that data was used for the definition of the critical group of CEA done in former assessments, while the second one corresponds to the use of data in deterministic assessments, as recommended by ICRP to estimate doses to the so--called 'representative person' . (author)

  5. Critical groups vs. representative person: dose calculations due to predicted releases from USEXA

    International Nuclear Information System (INIS)

    Ferreira, N.L.D.; Rochedo, E.R.R.; Mazzilli, B.P.

    2013-01-01

    The critical group cf Centro Experimental Aramar (CEA) site was previously defined based 00 the effluents releases to the environment resulting from the facilities already operational at CEA. In this work, effective doses are calculated to members of the critical group considering the predicted potential uranium releases from the Uranium Hexafluoride Production Plant (USEXA). Basically, this work studies the behavior of the resulting doses related to the type of habit data used in the analysis and two distinct situations are considered: (a) the utilization of average values obtained from official institutions (IBGE, IEA-SP, CNEN, IAEA) and from the literature; and (b) the utilization of the 95 tb percentile of the values derived from distributions fit to the obtained habit data. The first option corresponds to the way that data was used for the definition of the critical group of CEA done in former assessments, while the second one corresponds to the use of data in deterministic assessments, as recommended by ICRP to estimate doses to the so--called 'representative person' . (author)

  6. Single-dose, subcutaneous recombinant phenylalanine ammonia lyase conjugated with polyethylene glycol in adult patients with phenylketonuria: an open-label, multicentre, phase 1 dose-escalation trial.

    Science.gov (United States)

    Longo, Nicola; Harding, Cary O; Burton, Barbara K; Grange, Dorothy K; Vockley, Jerry; Wasserstein, Melissa; Rice, Gregory M; Dorenbaum, Alejandro; Neuenburg, Jutta K; Musson, Donald G; Gu, Zhonghua; Sile, Saba

    2014-07-05

    Phenylketonuria is an inherited disease caused by impaired activity of phenylalanine hydroxylase, the enzyme that converts phenylalanine to tyrosine, leading to accumulation of phenylalanine and subsequent neurocognitive dysfunction. Phenylalanine ammonia lyase is a prokaryotic enzyme that converts phenylalanine to ammonia and trans-cinnamic acid. We aimed to assess the safety, tolerability, pharmacokinetic characteristics, and efficacy of recombinant Anabaena variabilis phenylalanine ammonia lyase (produced in Escherichia coli) conjugated with polyethylene glycol (rAvPAL-PEG) in reducing phenylalanine concentrations in adult patients with phenylketonuria. In this open-label, phase 1, multicentre trial, single subcutaneous injections of rAvPAL-PEG were given in escalating doses (0·001, 0·003, 0·010, 0·030, and 0·100 mg/kg) to adults with phenylketonuria. Participants aged 18 years or older with blood phenylalanine concentrations of 600 μmol/L or higher were recruited from among patients attending metabolic disease clinics in the USA. The primary endpoints were safety and tolerability of rAvPAL-PEG. Secondary endpoints were the pharmacokinetic characteristics of the drug and its effect on concentrations of phenylalanine. Participants and investigators were not masked to assigned dose group. This study is registered with ClinicalTrials.gov, number NCT00925054. 25 participants were recruited from seven centres between May 6, 2008, and April 15, 2009, with five participants assigned to each escalating dose group. All participants were included in the safety population. The most frequently reported adverse events were injection-site reactions and dizziness, which were self-limited and without sequelae. Two participants had serious adverse reactions to intramuscular medroxyprogesterone acetate, a drug that contains polyethylene glycol as an excipient. Three of five participants given the highest dose of rAvPAL-PEG (0·100 mg/kg) developed a generalised skin rash

  7. Perfusion by Arterial Spin labelling following Single dose Tadalafil In Small vessel disease (PASTIS)

    DEFF Research Database (Denmark)

    Pauls, Mathilde M H; Clarke, Natasha; Trippier, Sarah

    2017-01-01

    vascular territories. The aim of this trial is to test the hypothesis that tadalafil increases cerebral blood flow in older people with small vessel disease. METHODS/DESIGN: Perfusion by Arterial Spin labelling following Single dose Tadalafil In Small vessel disease (PASTIS) is a phase II randomised double......-blind crossover trial. In two visits, 7-30 days apart, participants undergo arterial spin labelling to measure cerebral blood flow and a battery of cognitive tests, pre- and post-dosing with oral tadalafil (20 mg) or placebo. SAMPLE SIZE: 54 participants are required to detect a 15% increase in cerebral blood...

  8. An explanation for the multiplicative and the additive dose-effect relationship with the single-hit model

    International Nuclear Information System (INIS)

    Kottbauer, M.M.; Fleck, C.M.; Schoellnberger, H.

    1997-01-01

    For solid tumors and for leukemia the excess cancer rate after a single radiation dose D is different. The multiplicative model describes the excess solid tumor probability rate which is proportional to the background rate of cancer and dependent on dose D. The additive model describes the excess probability rate for leukaemia which is proportional to the dose D but unrelated to the spontaneous rate of cancer. A second great difference between the two models is the duration of the increased cancer probability rate. The multiplicative mode predicts that the additional cancer risk persist the whole lifetime after exposure and the additive model predicts excess risk over a period of time. With the Single-hit model (SHM) which is a multistage cancer model both dose-response relationships can be described. It will be shown that only small differences in the derivation will lead to the different relationships. We then analyze the incidence data of leukemia (1950-1987) and of all solid tumors (1958-1987) of the atomic bomb survivors. (author)

  9. Tapered fiber coupling of single photons emitted by a deterministically positioned single nitrogen vacancy center

    Energy Technology Data Exchange (ETDEWEB)

    Liebermeister, Lars, E-mail: lars.liebermeister@physik.uni-muenchen.de; Petersen, Fabian; Münchow, Asmus v.; Burchardt, Daniel; Hermelbracht, Juliane; Tashima, Toshiyuki [Fakultät für Physik, Ludwig-Maximilians-Universität München, 80799 München (Germany); Schell, Andreas W.; Benson, Oliver [Institut für Physik, Humboldt-Universität zu Berlin, 12489 Berlin (Germany); Meinhardt, Thomas; Krueger, Anke [Institut für Organische Chemie, Universität Würzburg, 97074 Würzburg (Germany); Wilhelm Conrad Roentgen Research Center for Complex Materials Systems, Universität Würzburg, 97074 Würzburg (Germany); Stiebeiner, Ariane; Rauschenbeutel, Arno [Atominstitut, Technische Universität Wien, 1020 Wien (Austria); Weinfurter, Harald; Weber, Markus, E-mail: markusweber@lmu.de [Fakultät für Physik, Ludwig-Maximilians-Universität München, 80799 München (Germany); Max-Planck-Institut für Quantenoptik, 85748 Garching (Germany)

    2014-01-20

    A diamond nano-crystal hosting a single nitrogen vacancy (NV) center is optically selected with a confocal scanning microscope and positioned deterministically onto the subwavelength-diameter waist of a tapered optical fiber (TOF) with the help of an atomic force microscope. Based on this nano-manipulation technique, we experimentally demonstrate the evanescent coupling of single fluorescence photons emitted by a single NV-center to the guided mode of the TOF. By comparing photon count rates of the fiber-guided and the free-space modes and with the help of numerical finite-difference time domain simulations, we determine a lower and upper bound for the coupling efficiency of (9.5 ± 0.6)% and (10.4 ± 0.7)%, respectively. Our results are a promising starting point for future integration of single photon sources into photonic quantum networks and applications in quantum information science.

  10. Parallel sorting algorithms

    CERN Document Server

    Akl, Selim G

    1985-01-01

    Parallel Sorting Algorithms explains how to use parallel algorithms to sort a sequence of items on a variety of parallel computers. The book reviews the sorting problem, the parallel models of computation, parallel algorithms, and the lower bounds on the parallel sorting problems. The text also presents twenty different algorithms, such as linear arrays, mesh-connected computers, cube-connected computers. Another example where algorithm can be applied is on the shared-memory SIMD (single instruction stream multiple data stream) computers in which the whole sequence to be sorted can fit in the

  11. Impact of caring for a child with cancer on single parents compared with parents from two-parent families.

    Science.gov (United States)

    Klassen, Anne F; Dix, David; Papsdorf, Michael; Klaassen, Robert J; Yanofsky, Rochelle; Sung, Lillian

    2012-01-01

    It is currently unknown how the intensive and often prolonged treatment of childhood cancer impacts on the lives of single parents. Our aims were to determine whether single parents differ from parents from two-parent families in terms of caregiver demand (the time and effort involved in caregiving), and health-related quality of life (HRQL). Forty single parents and 275 parents from two-parent families were recruited between November 2004 and February 2007 from five pediatric oncology centers in Canada. Parents were asked to complete a questionnaire booklet composed of items and scales to measure caregiver demand and HRQL (SF-36). The booklet also measured the following constructs: background and context factors, child factors, caregiving strain, intrapsychic factors, and coping factors. Single parents did not differ from parents from two-parent families in caregiving demand and physical and psychosocial HRQL. Compared with Canadian population norms for the SF-36, both groups reported clinically important differences (i.e., worse health) in psychosocial HRQL (effect size ≥ -2.00), while scores for physical HRQL were within one standard deviation of population norms. Our findings suggest that the impact of caregiving on single parents, in terms of caregiving demand and HRQL is similar to that of parents from two-parent families. Copyright © 2011 Wiley Periodicals, Inc.

  12. Pharmacokinetics, safety, and tolerability of varenicline in healthy adolescent smokers: a multicenter, randomized, double-blind, placebo-controlled, parallel-group study.

    Science.gov (United States)

    Faessel, Helene; Ravva, Patanjali; Williams, Kathryn

    2009-01-01

    Varenicline is approved as an aid to smoking cessation in adults aged > or =18 years. The goal of this study was to characterize the multiple-dose pharmacokinetics, safety, and tolerability of varenicline in adolescent smokers. This multicenter, randomized, double-blind, placebo-controlled, parallel-group study enrolled healthy 12- to 16-year-old smokers (> or =3 cigarettes daily) into high-body-weight (>55 kg) and low-body-weight (daily. The apparent renal clearance (CL/F) and volume of distribution (V/F) of varenicline and the effect of body weight on these parameters were estimated using nonlinear mixed-effects modeling. The high-body-weight group consisted of 35 subjects (65.7% male; 77.1% white; mean age, 15.2 years). The low-body-weight group consisted of 37 subjects (37.8% male; 48.6% white; mean age, 14.3 years). The pharmacokinetic parameters of varenicline were dose proportional over the dose range from 0.5 to 2 mg/d. The CL/F for a 70-kg adolescent was 10.4 L/h, comparable to that in a 70-kg adult. The estimated varenicline V/F was decreased in individuals of small body size, thus predicting a varenicline C(max) approximately 30% greater in low-body-weight subjects than in high-body-weight subjects. In high-body-weight subjects, steady-state varenicline exposure, as represented by the AUC(0-24), was 197.0 ng . h/mL for varenicline 1 mg BID and 95.7 ng . h/mL for varenicline 0.5 mg BID, consistent with values reported previously in adult smokers at the equivalent doses. In low-body-weight subjects, varenicline exposure was 126.3 ng . h/mL for varenicline 0.5 mg BID and 60.1 ng . h/mL for varenicline 0.5 mg once daily, values at the lower end of the range observed previously in adults at doses of 1 mg BID and 0.5 mg BID, respectively. Among high-body-weight subjects, adverse events (AEs) were reported by 57.1% of subjects in both the high- and low-dose varenicline groups and by 14.3% of subjects in the placebo group; among low-body-weight subjects, AEs

  13. Social support and education groups for single mothers: a randomized controlled trial of a community-based program.

    Science.gov (United States)

    Lipman, Ellen L; Boyle, Michael H

    2005-12-06

    Members of families headed by single mothers are at increased risk of psychosocial disadvantage and mental health problems. We assessed the effect of a community-based program of social support and education groups for single mothers of young children on maternal well-being and parenting. We recruited 116 single mothers of children 3 to 9 years old through community advertisements. Eligible mothers were randomly assigned either to participate in a 10-week program of group sessions (1.5 hours per week) offering social support and education, with a parallel children's activity group, or to receive a standard list of community resources and the option to participate in group sessions at the end of the follow-up period. Interviewers blinded to the randomization collected assessment data from all mothers at baseline and at 3 follow-up visits (immediately after the intervention and at 3 and 6 months after the intervention). Outcome measures were self-reported mood, self-esteem, social support and parenting. Between February 2000 and April 2003, the program was offered to 9 groups of single mothers. Most of the mothers in the trial reported high levels of financial and mental health problems. In the short term (after the intervention), mothers in the intervention group had improved scores for mood (p effect = 0.55) and self-esteem (p effect = 0.29) compared with mothers in the control group; scores for the other 2 measures did not differ between the groups. Growth curve analysis of program effects over the follow-up period showed improvement in all 4 outcomes, with no significant difference between the intervention and control groups. This community-based program of group sessions offering social support and education to low-income single mothers had positive short-term effects on mood and self-esteem but not on social support and parenting. Longer follow-up showed attenuation of these effects.

  14. Comparative bioavailability and pharmacokinetics of two oral formulations of flurbiprofen: a single-dose, randomized, open-label, two-period, crossover study in Pakistani subjects.

    Science.gov (United States)

    Qayyum, Aisha; Najmi, Muzammil Hasan; Abbas, Mateen

    2013-11-01

    Comparative bioavailability studies are conducted to establish the bioequivalence of generic formulation with that of branded reference formulation, providing confidence to clinicians to use these products interchangeably. This study was carried out to compare a locally manufactured formulation of flurbiprofen with that of a branded product. Twenty two healthy male adults received a single dose of flurbiprofen (100mg) either generic or branded product according to randomization scheme on each of 2 periods. Blood samples were collected and plasma flurbiprofen concentration was determined by a validated HPLC method. Pharmacokinetic parameters like AUC(0-t), AUC(0-oo), Cmax, Tmax, t½, Vd and clearance were determined. The 90% CI for the ratio of geometric means of test to reference product's pharmacokinetic variables was calculated. Pharmacokinetic parameters for two formulations were comparable. Ratio of means of AUC(0-24), AUC(0-oo) and Cmax for test to reference products and 90% CI for these ratios were within the acceptable range. The p-values calculated by TOST were much less than the specified value (p-0.05). ANOVA gave p-values which were more than the specified value (p-0.05) for sequence, subject, period and formulation. Test formulation of flurbiprofen (tablet Flurso) was found to meet the criteria for bioequivalence to branded product (tablet Ansaid) based on pharmacokinetic parameters.

  15. Numerical evaluation of two-center integrals over Slater type orbitals

    Energy Technology Data Exchange (ETDEWEB)

    Kurt, S. A., E-mail: slaykurt@gmail.com [Department of Physics, Natural Sciences Institute, Ondokuz Mayıs University, 55139, Samsun (Turkey); Yükçü, N., E-mail: nyukcu@gmail.com [Department of Energy Systems Engineering, Faculty of Technology, Adıyaman University, 02040, Adıyaman (Turkey)

    2016-03-25

    Slater Type Orbitals (STOs) which one of the types of exponential type orbitals (ETOs) are used usually as basis functions in the multicenter molecular integrals to better understand physical and chemical properties of matter. In this work, we develop algorithms for two-center overlap and two-center two-electron hybrid and Coulomb integrals which are calculated with help of translation method for STOs and some auxiliary functions by V. Magnasco’s group. We use Mathematica programming language to produce algorithms for these calculations. Numerical results for some quantum numbers are presented in the tables. Consequently, we compare our obtained numerical results with the other known literature results and other details of evaluation method are discussed.

  16. Numerical evaluation of two-center integrals over Slater type orbitals

    International Nuclear Information System (INIS)

    Kurt, S. A.; Yükçü, N.

    2016-01-01

    Slater Type Orbitals (STOs) which one of the types of exponential type orbitals (ETOs) are used usually as basis functions in the multicenter molecular integrals to better understand physical and chemical properties of matter. In this work, we develop algorithms for two-center overlap and two-center two-electron hybrid and Coulomb integrals which are calculated with help of translation method for STOs and some auxiliary functions by V. Magnasco’s group. We use Mathematica programming language to produce algorithms for these calculations. Numerical results for some quantum numbers are presented in the tables. Consequently, we compare our obtained numerical results with the other known literature results and other details of evaluation method are discussed.

  17. Cumulative effective radiation dose received by blunt trauma patients arriving to a military level I trauma center from point of injury and interhospital transfers.

    Science.gov (United States)

    Van Arnem, Kerri A; Supinski, David P; Tucker, Jonathan E; Varney, Shawn

    2016-12-01

    Trauma patients sustaining blunt injuries are exposed to multiple radiologic studies. Evidence indicates that the risk of cancer from exposure to ionizing radiation rises in direct proportion to the cumulative effective dose (CED) received. The purpose of this study is to quantify the amount of ionizing radiation accumulated when arriving directly from point of injury to San Antonio Military Medical Center (SAMMC), a level I trauma center, compared with those transferred from other facilities. A retrospective record review was conducted from 1st January 2010 through 31st December 2012. The SAMMC trauma registry, electronic medical records, and the digital radiology imaging system were searched for possible candidates. The medical records were then analyzed for sex, age, mechanism of injury, received directly from point of injury (direct group), transfer from another medical facility (transfer group), computed tomographic scans received, dose-length product, CED of radiation, and injury severity score. A diagnostic imaging physicist then calculated the estimated CED each subject received based on the dose-length product of each computed tomographic scan. A total of 300 patients were analyzed, with 150 patients in the direct group and 150 patients in the transfer group. Both groups were similar in age and sex. Patients in the transfer group received a significantly greater CED of radiation compared with the direct group (mean, 37.6 mSv vs 28 mSv; P=.001). The radiation received in the direct group correlates with a lifetime attributable risk (LAR) of 1 in 357 compared with the transfer group with an increase in LAR to 1 in 266. Patients transferred to our facility received a 34% increase in ionizing radiation compared with patients brought directly from the injury scene. This increased dose of ionizing radiation contributes to the LAR of cancer and needs to be considered before repeating imaging studies. III. Published by Elsevier Inc.

  18. Efficacy of a single dose of milbemycin oxime/praziquantel combination tablets, Milpro(®), against adult Echinococcus multilocularis in dogs and both adult and immature E. multilocularis in young cats.

    Science.gov (United States)

    Cvejic, Dejan; Schneider, Claudia; Fourie, Josephus; de Vos, Christa; Bonneau, Stephane; Bernachon, Natalia; Hellmann, Klaus

    2016-03-01

    Two single-site, laboratory, negatively controlled, masked, randomised dose confirmation studies were performed: one in dogs, the other in cats. After a period of acclimatisation, both the dogs and cats were orally infected with Echinococcus multilocularis protoscoleces. In the dog study, 10 dogs received a single dose of Milpro® tablets at a minimum dose of 0.5 mg/kg milbemycin oxime and 5 mg/kg praziquantel 18 days post-infection and 10 dogs received no treatment. In the cat study, 10 cats received a single dose of Milpro® tablets at a minimum dose of 2 mg/kg milbemycin oxime and 5 mg/kg praziquantel 7 days post-infection, 10 cats received a single dose of the treatment 18 days post-infection and 10 cats remained untreated. In both studies, intestinal worm counts were performed 23 days post-infection at necropsy. No worms were retrieved from any of the 30 treated animals. Nine of 10 control dogs had multiple worms (geometric mean 91, arithmetic mean 304) and all 10 control cats had multiple worms (geometric mean 216, arithmetic mean 481). The difference in worm counts between all three treated groups and their controls was highly significant (ANOVA p values of log transformed data dogs and cats as well as for elimination of immature E. multilocularis in cats as evidenced by the effectiveness of treatment 7 days post-infection. The treatments were well accepted and tolerated, and there were no adverse drug reactions observed.

  19. Hypertrophic Cardiomyopathy After a Single Dose of Dexamethasone in a Preterm Infant

    Directory of Open Access Journals (Sweden)

    Yusuf Kale

    2015-08-01

    Full Text Available Dexamethasone is widely used in preterm infants with severe pulmonary disease. Hypertrophic cardiomyopathy (HCM is a transient side effect observed after multiple doses of dexamethasone. We report a preterm infant with myocardial hypertrophy after a single dose of dexamethasone (0.5 mg/kg used to treat laryngeal edema secondary to prolonged intubation. A benign course was observed without left ventricular outflow tract obstruction and with recovery within 4 weeks. Myocardial effects of dexamethasone may be independent of dose and duration of treatment. The risk/benefit ratio must be carefully considered before using even a single dose of dexamethasone in preterm infants.

  20. Scissor-type knife significantly improves self-completion rate of colorectal endoscopic submucosal dissection: Single-center prospective randomized trial.

    Science.gov (United States)

    Yamashina, Takeshi; Takeuchi, Yoji; Nagai, Kengo; Matsuura, Noriko; Ito, Takashi; Fujii, Mototsugu; Hanaoka, Noboru; Higashino, Koji; Uedo, Noriya; Ishihara, Ryu; Iishi, Hiroyasu

    2017-05-01

    Colorectal endoscopic submucosal dissection (C-ESD) is recognized as a difficult procedure. Recently, scissors-type knives were launched to reduce the difficulty of C-ESD. The aim of this study was to evaluate the efficacy and safety of the combined use of a scissors-type knife and a needle-type knife with a water-jet function (WJ needle-knife) for C-ESD compared with using the WJ needle-knife alone. This was a prospective randomized controlled trial in a referral center. Eighty-five patients with superficial colorectal neoplasms were enrolled and randomly assigned to undergo C-ESD using a WJ needle-knife alone (Flush group) or a scissor-type knife-supported WJ needle-knife (SB Jr group). Procedures were conducted by two supervised residents. Primary endpoint was self-completion rate by the residents. Self-completion rate was 67% in the SB Jr group, which was significantly higher than that in the Flush group (39%, P = 0.01). Even after exclusion of four patients in the SB Jr group in whom C-ESD was completed using the WJ needle-knife alone, the self-completion rate was significantly higher (63% vs 39%; P = 0.03). Median procedure time among the self-completion cases did not differ significantly between the two groups (59 vs 51 min; P = 0.14). No fatal adverse events were observed in either group. In this single-center phase II trial, scissor-type knife significantly improved residents' self-completion rate for C-ESD, with no increase in procedure time or adverse events. A multicenter trial would be warranted to confirm the validity of the present study. © 2016 Japan Gastroenterological Endoscopy Society.

  1. The development of a revised version of multi-center molecular Ornstein-Zernike equation

    Science.gov (United States)

    Kido, Kentaro; Yokogawa, Daisuke; Sato, Hirofumi

    2012-04-01

    Ornstein-Zernike (OZ)-type theory is a powerful tool to obtain 3-dimensional solvent distribution around solute molecule. Recently, we proposed multi-center molecular OZ method, which is suitable for parallel computing of 3D solvation structure. The distribution function in this method consists of two components, namely reference and residue parts. Several types of the function were examined as the reference part to investigate the numerical robustness of the method. As the benchmark, the method is applied to water, benzene in aqueous solution and single-walled carbon nanotube in chloroform solution. The results indicate that fully-parallelization is achieved by utilizing the newly proposed reference functions.

  2. Coarse-grain parallel solution of few-group neutron diffusion equations

    International Nuclear Information System (INIS)

    Sarsour, H.N.; Turinsky, P.J.

    1991-01-01

    The authors present a parallel numerical algorithm for the solution of the finite difference representation of the few-group neutron diffusion equations. The targeted architectures are multiprocessor computers with shared memory like the Cray Y-MP and the IBM 3090/VF, where coarse granularity is important for minimizing overhead. Most of the work done in the past, which attempts to exploit concurrence, has concentrated on the inner iterations of the standard outer-inner iterative strategy. This produces very fine granularity. To coarsen granularity, the authors introduce parallelism at the nested outer-inner level. The problem's spatial domain was partitioned into contiguous subregions and assigned a processor to solve for each subregion independent of all other subregions, hence, processors; i.e., each subregion is treated as a reactor core with imposed boundary conditions. Since those boundary conditions on interior surfaces, referred to as internal boundary conditions (IBCs), are not known, a third iterative level, the recomposition iterations, is introduced to communicate results between subregions

  3. Association between Pre-Operative Cefazolin Dose and Surgical Site Infection in Obese Patients.

    Science.gov (United States)

    Peppard, William J; Eberle, David G; Kugler, Nathan W; Mabrey, Danielle M; Weigelt, John A

    A fixed dose of cefazolin results in serum concentrations that decrease as body mass increases. Current national guidelines suggest a pre-operative cefazolin dose of two grams may be insufficient for patients ≥120 kg; thus a three gram dose is recommended. These recommendations, however, are based on pharmacokinetic rather than outcome data. We evaluate the efficacy of pre-operative cefazolin two gram and three gram doses as measured by the rate of surgical site infection (SSI). We conducted a retrospective review of adult patients ≥100 kg who were prescribed cefazolin as surgical prophylaxis between September 1, 2012 and May 31, 2013 at an academic medical center. Patients were excluded if cefazolin was prescribed but not administered, had a known infection at the site of surgery, or inappropriately received cefazolin prophylaxis based on surgical indication. The SSIs were identified by documentation of SSI in the medical record or findings consistent with the standard Centers for Disease Control and Prevention definition. Inpatient and outpatient records up to 90 days post-operative were reviewed for delayed SSI. Four hundred eighty-three surgical cases were identified in which pre-operative cefazolin was prescribed. Forty-seven patients were excluded leaving a total of 436 patients for final analysis: 152 in the cefazolin two gram group and 284 in the three gram group. Baseline demographics were similar between groups with a mean follow-up duration of 77 days for both groups. Unadjusted SSI rates were 7.2% and 7.4% (odds ratio [OR] 0.98, p = 0.95), for the two gram and three gram groups, respectively. When differences in follow-up between groups were considered and logistic regression was adjusted with propensity score, there remained no difference in SSI rates (OR 0.87, 95% confidence interval 0.36-2.06, p = 0.77). In otherwise similar obese surgical patients weighing ≥100 kg, the administration of a pre-operative cefazolin two gram dose is

  4. Benefits of the effective dose equivalent concept at a medical center

    International Nuclear Information System (INIS)

    Vetter, R.J.; Classic, K.L.

    1991-01-01

    A primary objective of the recommendations of the International Committee on Radiological Protection Publication 26 is to insure that no source of radiation exposure is unjustified in relation to its benefits. This objective is consistent with goals of the Radiation Safety Committee and Institutional Review Board at medical centers where research may involve radiation exposure of human subjects. The effective dose equivalent concept facilitates evaluation of risk by those who have little or no knowledge of quantities or biological effects of radiation. This paper presents effective dose equivalent data used by radiation workers and those who evaluate human research protocols as these data relate to personal dosimeter reading, entrance skin exposure, and target organ dose. The benefits of using effective dose equivalent to evaluate risk of medical radiation environments and research protocols are also described

  5. Coronary vasodilatory action after a single dose of nicorandil

    NARCIS (Netherlands)

    H. Suryapranata (Harry); P.W.J.C. Serruys (Patrick); P.J. de Feyter (Pim); P.D. Verdouw (Pieter); P.G. Hugenholtz (Paul)

    1988-01-01

    textabstractCoronary hemodynamics and vasodilatory effects on major epicardial arteries were investigated after a single dose of nicorandil in 22 patients undergoing cardiac catheterization for suspected coronary artery disease. Nicorandil, 20 mg, was administered sublingually to 11 consecutive

  6. Once-daily omeprazole/sodium bicarbonate heals severe refractory reflux esophagitis with morning or nighttime dosing.

    Science.gov (United States)

    Orbelo, Diana M; Enders, Felicity T; Romero, Yvonne; Francis, Dawn L; Achem, Sami R; Dabade, Tushar S; Crowell, Michael D; Geno, Debra M; DeJesus, Ramona S; Namasivayam, Vikneswaran; Adamson, Steven C; Arora, Amindra S; Majka, Andrew J; Alexander, Jeffrey A; Murray, Joseph A; Lohse, Matthew; Diehl, Nancy N; Fredericksen, Mary; Jung, Kee Wook; Houston, Margaret S; O'Neil, Angela E; Katzka, David A

    2015-01-01

    Morning dose or twice-daily proton pump inhibitor (PPI) use is often prescribed to heal severe reflux esophagitis. Compare the effect of single dose morning (control arm) versus nighttime (experimental arm) omeprazole/sodium bicarbonate (Zegerid(®)) (IR-OME) on esophagitis and gastroesophageal reflux symptoms. Adult outpatients with Los Angeles grade C or D esophagitis were allocated to open-label 40 mg IR-OME once a day for 8 weeks in a prospective, randomized, parallel design, single center study. Esophagogastroduodenoscopy (EGD) and validated self-report symptom questionnaires were completed at baseline and follow-up. Intention-to-treat and per-protocol analyses were performed. Ninety-two of 128 (72 %) eligible subjects participated [64 (70 %) male, mean age 58 (range 19-86), median BMI 29 (range 21-51), 58 C:34 D]. Overall, 81 (88 %) subjects healed [n = 70 (76 %)] or improved [n = 11 (12 %)] erosions. There was no significant difference (morning vs. night) in mucosal healing [81 vs. 71 %, (p = 0.44)] or symptom resolution [heartburn (77 vs. 65 %, p = 0.12), acid regurgitation (82 vs. 73 %, p = 0.28)]. Prevalence of newly identified Barrett's esophagus was 14 % with half diagnosed only after treatment. Once-daily IR-OME (taken morning or night) effectively heals severe reflux esophagitis and improves GERD symptoms. Results support the clinical practice recommendation to repeat EGD after 8 weeks PPI therapy in severe esophagitis patients to assure healing and exclude Barrett's esophagus.

  7. The effect of single low-dose dexamethasone on blood glucose concentrations in the perioperative period: a randomized, placebo-controlled investigation in gynecologic surgical patients.

    Science.gov (United States)

    Murphy, Glenn S; Szokol, Joseph W; Avram, Michael J; Greenberg, Steven B; Shear, Torin; Vender, Jeffery S; Gray, Jayla; Landry, Elizabeth

    2014-06-01

    The effect of single low-dose dexamethasone therapy on perioperative blood glucose concentrations has not been well characterized. In this investigation, we examined the effect of 2 commonly used doses of dexamethasone (4 and 8 mg at induction of anesthesia) on blood glucose concentrations during the first 24 hours after administration. Two hundred women patients were randomized to 1 of 6 groups: Early-control (saline); Early-4 mg (4 mg dexamethasone); Early-8 mg (8 mg dexamethasone); Late-control (saline); Late-4 mg (4 mg dexamethasone); and Late-8 mg (8 mg dexamethasone). Blood glucose concentrations were measured at baseline and 1, 2, 3, and 4 hours after administration in the early groups and at baseline and 8 and 24 hours after administration in the late groups. The incidence of hyperglycemic events (the number of patients with at least 1 blood glucose concentration >180 mg/dL) was determined. Blood glucose concentrations increased significantly over time in all control and dexamethasone groups (from median baselines of 94 to 102 mg/dL to maximum medians ranging from 141 to 161.5 mg/dL, all P < 0.001). Blood glucose concentrations did not differ significantly between the groups receiving dexamethasone (either 4 or 8 mg) and those receiving saline at any measurement time. The incidence of hyperglycemic events did not differ in any of the early (21%-28%, P = 0.807) or late (13%-24%, P = 0.552) groups. Because blood glucose concentrations during the first 24 hours after administration of single low-dose dexamethasone did not differ from those observed after saline administrations, these results suggest clinicians need not avoid using dexamethasone for nausea and vomiting prophylaxis out of concerns related to hyperglycemia.

  8. Absorbed dose optimization in the microplanar beam radiotherapy

    International Nuclear Information System (INIS)

    Company, F.Z.; Jaric, J.; Allen, B.J.

    1996-01-01

    Full text: Recent advances in synchrotron generated X-ray beams with high fluence rate, small divergence and sharply defined microbeam margins permit investigation of the application of an array of closely spaced, parallel or converging microbeams for radiotherapy. The proposed technique takes advantage of the repair mechanism hypothesis of capillary endothelial cells between alternate microbeam zones, which regenerates the lethally irradiated capillaries. Unlike a pencil beam, more accurate dose calculation, beam width and spacing are essential to minimise radiation damage to normal tissue cells outside the target. The absorbed dose between microbeam zones should be kept below the threshold for irreversible radiation damage. Thus the peak-to-valley ratio for the dose distribution should be optimized. The absorbed dose profile depends on the energy of the incident beam and the composition and density of the medium. Using Monte Carlo computations, the radial absorbed dose of single 24 x 24 μm 2 cross-section X-ray beams of different energies in a tissue/lung/tissue phantom was investigated. The results indicated that at 100 keV, closely spaced square cross-sectional microbeams can be applied to the lung. A bundle of parallel 24 μm-wide planar microbeams spaced at 200 μm intervals provides much more irradiation coverage of tissue than is provided by a bundle of parallel, square cross-sectional microbeam, although the former is associated with much smaller Peak (maximum absorbed dose on the beam axis) -to-Valley ( minimum interbeam absorbed dose ) ratios than the latter. In this study the lateral and depth dose of single and multiple microplanar beams with beam dimensions of width 24 μm and 48 μm and height 2-20 cm with energy of 100 keV in a tissue/lung/tissue phantom are investigated. The EGS4 Monte Carlo code is used to calculate dose profiles at different depths and bundles of beams (2 x 2 cm 2 to 20 x 20 cm 2 square cross section) with a 150 μm 200 μm and

  9. A Study on the Single-dose Oral Toxicity of Super Key in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Jinhee Kim

    2015-09-01

    Full Text Available Objectives: This study was performed to analyze the single-dose oral toxicity of the super key (processed sulfur. Methods: All experiments were conducted at Medvill, an institution authorized to perform non-clinical studies, under the Good Laboratory Practice (GLP regulations. In order to investigate the oral toxicity of super key We administered it orally to Sprague-Dawley (SD rats. The SD rats were divided into four groups of five male and five female animals per group: group 1 being the control group and groups 2, 3, and 4 being the experimental groups. Doses of super key 500 mg/kg, 1,000 mg/kg and 2,000 mg/kg were administered to the experimental groups, and a dose of normal saline solution, 10 mL/kg, was administered to the control group. We examined the survival rates, weights, clinical signs, gross findings and necropsy findings. This study was conducted under the approval of the Institutional Animal Ethics Committee. (Approval number: A01-14018. Results: No deaths or abnormalities occurred in any of the four groups. Although slight decreases in the weights of some female rats were noted, no significant changes in weights or differences in the gross findings between the control group and the experimental groups were observed. To check for abnormalities in organs, we used microscopy to examine representative histological sections of each specified organ; the results showed no significant differences in any of the organs. Conclusion: The results of this research showed that administration of 500 ─ 2,000 mg/kg of super key did not cause any changes in the weights or in the results of necropsy examinations. Neither did it result in any mortalities. The above findings suggest that treatment with super key is relatively safe. Further studies on this subject are needed to yield more concrete evidence.

  10. Quality assurance of 3-D conformal radiation therapy for a cooperative group trial - RTOG 3D QA center initial experience

    International Nuclear Information System (INIS)

    Michalski, Jeff M.; Purdy, James A.; Harms, William B.; Bosch, Walter R.; Oehmke, Frederick; Cox, James D.

    1996-01-01

    PURPOSE: 3-D conformal radiation therapy (3DCRT) holds promise in allowing safe escalation of radiation dose to increase the local control of prostate cancer. Prospective evaluation of this new modality requires strict quality assurance (QA). We report the results of QA review on patients receiving 3DCRT for prostate cancer on a cooperative group trial. MATERIALS and METHODS: In 1993 the NCI awarded the ACR/RTOG and nine institutions an RFA grant to study the use of 3DCRT in the treatment of prostate cancer. A phase I/II trial was developed to: a) test the feasibility of conducting 3DCRT radiation dose escalation in a cooperative group setting; b) establish the maximum tolerated radiation dose that can be delivered to the prostate; and c) quantify the normal tissue toxicity rate when using 3DCRT. In order to assure protocol compliance each participating institution was required to implement data exchange capabilities with the RTOG 3D QA center. The QA center reviews at a minimum the first five case from each participating center and spot checks subsequent submissions. For each case review the following parameters are evaluated: 1) target volume delineation, 2) normal structure delineation, 3) CT data quality, 4) field placement, 5) field shaping, and 6) dose distribution. RESULTS: Since the first patient was registered on August 23, 1994, an additional 170 patients have been accrued. Each of the nine original approved institutions has participated and three other centers have recently passed quality assurance bench marks for study participation. Eighty patients have been treated at the first dose level (68.4 Gy minimum PTV dose) and accrual is currently ongoing at the second dose level (73.8 Gy minimum PTV dose). Of the 124 cases that have undergone complete or partial QA review, 30 cases (24%) have had some problems with data exchange. Five of 67 CT scans were not acquired by protocol standards. Target volume delineation required the submitting institution

  11. Pharmacokinetic Properties of Three Forms of Vaginal Progesterone Administered in Either Single Or Multiple Dose Regimen in Healthy Post-menopausal Chinese Women

    Directory of Open Access Journals (Sweden)

    Jianzhong Shentu

    2017-04-01

    Full Text Available Objective: A generic vaginal progesterone gel has recently been developed in China. Little is known about its pharmacokinetic properties in Chinese subjects. The purpose of our study was to investigate the pharmacokinetics of three forms of vaginal progesterone gel (test formulations at 4 and 8% strength vs. a reference formulation: Crinone 8% in Chinese healthy post-menopausal women.Methods: This study consisted of two parts study. The part 1 study was a single-center, open-label, 3-period study. Twelve healthy post-menopausal women were to evaluate the safety and pharmacokinetics of 45 mg vaginal progesterone gel (Test 4% following single dose and multiple doses administered once every other day (q.o.d. for six times or once daily (q.d. for 6 days. The part 2 study was a randomized, open-label, 3-stage crossover study. Twelve post-menopausal women received 90 mg vaginal progesterone gel (Test 8% or 90 mg Crinone (Reference 8% following single dose and multiple doses (q.o.d. or q.d.. Plasma concentrations of progesterone were measured up to 72 h by using a validated liquid chromatography tandem-mass spectrometry method. The primary pharmacokinetic parameters, maximum plasma concentration (Cmax and area under the plasma concentration–time curve (AUC from time zero to last measurable concentration (AUC0-t and extrapolated to infinity (AUC0-∞ were compared by an analysis of variance using log-transformed data.Results: Totally 24 subjects were enrolled in and completed the study. Following single dose, The geometric mean Cmax values for Test 4%, Test 8%, and Crinone 8% were 6.35, 10.34, 10.45 ng/mL, and their geometric mean AUC0-t (AUC0-∞ were 113.73 (118.00, 169.39 (173.98, and 190.07 (201.13 ng⋅h/mL, respectively. The mean T1/2 values of progesterone were 11.00, 10.92, and 11.40 h, respectively. For 8% test formulation vs. reference, the 90% CIs of the least squares mean test/reference ratios of Cmax, AUC0-t, and AUC0-∞ were 78.32–124

  12. Esophageal Toxicity From High-Dose, Single-Fraction Paraspinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Cox, Brett W.; Jackson, Andrew; Hunt, Margie; Bilsky, Mark; Yamada, Yoshiya

    2012-01-01

    Purpose: To report the esophageal toxicity from single-fraction paraspinal stereotactic radiosurgery (SRS) and identify dosimetric and clinical risk factors for toxicity. Methods and Materials: A total of 204 spinal metastases abutting the esophagus (182 patients) were treated with high-dose single-fraction SRS during 2003-2010. Toxicity was scored using the National Cancer Institute Common Toxicity Criteria for Adverse Events, version 4.0. Dose-volume histograms were combined to generate a comprehensive atlas of complication incidence that identifies risk factors for toxicity. Correlation of dose-volume factors with esophageal toxicity was assessed using Fisher’s exact test and logistic regression. Clinical factors were correlated with toxicity. Results: The median dose to the planning treatment volume was 24 Gy. Median follow-up was 12 months (range, 3-81). There were 31 (15%) acute and 24 (12%) late esophageal toxicities. The rate of grade ≥3 acute or late toxicity was 6.8% (14 patients). Fisher’s exact test resulted in significant median splits for grade ≥3 toxicity at V12 = 3.78 cm 3 (relative risk [RR] 3.7, P=.05), V15 = 1.87 cm 3 (RR 13, P=.0013), V20 = 0.11 cm 3 (RR 6, P=0.01), and V22 = 0.0 cm 3 (RR 13, P=.0013). The median split for D2.5 cm 3 (14.02 Gy) was also a significant predictor of toxicity (RR 6; P=.01). A highly significant logistic regression model was generated on the basis of D2.5 cm 3 . One hundred percent (n = 7) of grade ≥4 toxicities were associated with radiation recall reactions after doxorubicin or gemcitabine chemotherapy or iatrogenic manipulation of the irradiated esophagus. Conclusions: High-dose, single-fraction paraspinal SRS has a low rate of grade ≥3 esophageal toxicity. Severe esophageal toxicity is minimized with careful attention to esophageal doses during treatment planning. Iatrogenic manipulation of the irradiated esophagus and systemic agents classically associated with radiation recall reactions are

  13. Using machine learning to identify structural breaks in single-group interrupted time series designs.

    Science.gov (United States)

    Linden, Ariel; Yarnold, Paul R

    2016-12-01

    Single-group interrupted time series analysis (ITSA) is a popular evaluation methodology in which a single unit of observation is being studied, the outcome variable is serially ordered as a time series and the intervention is expected to 'interrupt' the level and/or trend of the time series, subsequent to its introduction. Given that the internal validity of the design rests on the premise that the interruption in the time series is associated with the introduction of the treatment, treatment effects may seem less plausible if a parallel trend already exists in the time series prior to the actual intervention. Thus, sensitivity analyses should focus on detecting structural breaks in the time series before the intervention. In this paper, we introduce a machine-learning algorithm called optimal discriminant analysis (ODA) as an approach to determine if structural breaks can be identified in years prior to the initiation of the intervention, using data from California's 1988 voter-initiated Proposition 99 to reduce smoking rates. The ODA analysis indicates that numerous structural breaks occurred prior to the actual initiation of Proposition 99 in 1989, including perfect structural breaks in 1983 and 1985, thereby casting doubt on the validity of treatment effects estimated for the actual intervention when using a single-group ITSA design. Given the widespread use of ITSA for evaluating observational data and the increasing use of machine-learning techniques in traditional research, we recommend that structural break sensitivity analysis is routinely incorporated in all research using the single-group ITSA design. © 2016 John Wiley & Sons, Ltd.

  14. ABO Blood Group and Endometrial Carcinoma: A Preliminary Single-Center Experience from Saudi Arabia.

    Science.gov (United States)

    Abu-Zaid, Ahmed; Alsabban, Mohannad; Abuzaid, Mohammed; Alomar, Osama; Al-Badawi, Ismail A; Salem, Hany

    2017-12-18

    Inherited ABO blood groups have been shown to play possible contributions in the pathogenesis of various gynecologic and non-gynecologic carcinomas. With regard to gynecologic carcinomas, there is a confined number of studies that explored the relationship between ABO blood group and endometrial carcinoma (EC) in the PubMed-indexed literature. To the best of our knowledge, no such study has ever been conducted in Saudi Arabia. Our study has two objectives: (I) to determine the prevalence of ABO blood groups among Saudi patients with EC, and (II) to explore the relationship between ABO blood group and several clinico-pathological prognostic parameters (namely: menopausal status [age], body mass index [BMI], tumor grade, FIGO [Fédération Internationale de Gynécologie et d'Obstétrique] stage and recurrence) in Saudi patients with EC. A retrospective cross-sectional study from 01-January-2010 to 31-July-2014 was conducted at King Faisal Specialist Hospital & Research Centre, Riyadh, Saudi Arabia - a referral tertiary healthcare institute. One-hundred and fourteen patients (n=114) were included in the study. Clinico-pathological data were extrapolated from medical records, and their association with ABO blood groups were evaluated. Categorical data were presented as number of cases (n) and percentages (%). Two-tailed Chi-square test was used for univariate analysis. For all purposes, p values 28 kg/m 2 (84.2%), diagnosed with early FIGO stage I-II (76.3%) and developed no recurrence (86.8%). The frequencies of ABO blood group types A, B, AB, and O were 28.1%, 12.3%, 3.5% and 56.1%, respectively. When ABO blood groups were analyzed as four different types (A, B, AB and O), O-type was the most common ABO blood group in pre- and post-menopausal EC patients (43.8% and 58.2%, respectively; p=0.14). There were no statistically significant correlations between ABO blood groups and all the examined clinico-pathological factors. Moreover, when ABO blood groups were

  15. Type Synthesis of Parallel Mechanisms with the First Class GF Sets and Two-Dimensional Rotations

    Directory of Open Access Journals (Sweden)

    Jialun Yang

    2012-09-01

    Full Text Available The novel design of parallel mechanisms plays a key role in the potential application of parallel mechanisms. In this paper, the type synthesis of parallel mechanisms with the first class GF sets and two-dimensional rotations is studied. The rule of two-dimensional rotations is given, which lays the theoretical foundation for the intersection operations of specific GF sets. Next, kinematic limbs with specific characteristics are designed according to the 2-D and 3-D axes movement theorems. Finally, several synthesized parallel mechanisms with the first class GF sets and two-dimensional rotations are illustrated to show the effectiveness of the proposed methodology.

  16. Time and dose-related changes in the thickness of pig skin after irradiation with single doses of 90Sr/90Y β-rays

    International Nuclear Information System (INIS)

    Rezvani, M.; Hamlet, R.; Hopewell, J.W.; Sieber, V.K.

    1994-01-01

    Time-related changes in pig skin thickness have been evaluated using a non-invasive ultrasound technique after exposure to a range of single doses of 90 Sr/ 90 Yr β-rays. The reduction in relative skin thickness developed in two distinct phases: the first was between 12 and 20 weeks postirradiation. No further changes were then seen until 52 weeks postirradiation when a second phase of skin thinning was observed. This was complete after 76 weeks and no further changes in relative skin thickness were seen in the maximum follow up period of 129 weeks. The timings of these phases of damage were independent of the radiation dose, however, the severity of both phases of radiation-induced skin thinning were dose related. (Author)

  17. Determination of Effect of Low Dose Vs Moderate Dose of Clofibrate on the Decreasing in Serum Bilirubin Level in the Term Healthy Neonate

    OpenAIRE

    Mohammad Ashkan Moslehi; Narges Pishva

    2007-01-01

    Objective: This study was performed to determine the effect of low doses (25 mg/Kg) vs. moderate doses (50 mg/Kg) of clofibrate in treatment of non-hemolytic hyperbilirubin¬emia in healthy term neonates. Material & Methods: A clinical randomized controlled trial was performed in three groups of healthy term neonates. One group was treated with a single low dose of clofibrate (25 mg/Kg) while another group received a single moderate dose (50mg/kg) both orally plus phototherapy; the results wer...

  18. Piloting CenteringParenting in Two Alberta Public Health Well-Child Clinics.

    Science.gov (United States)

    Johnston, Jennifer Cyne; McNeil, Deborah; van der Lee, Germaeline; MacLeod, Cheryl; Uyanwune, Yvonne; Hill, Kaitlyn

    2017-05-01

    To pilot a group health service delivery model, CenteringParenting, for new parents, to assess its feasibility and impact on maternal and infant outcomes. Families attended six, 2-hr group sessions in their child's first year of life with three to seven other families. Health assessments, parent-led discussions, and vaccinations occurred within the group. Demographic, breastfeeding, vaccination, maternal psychosocial health, parenting, and satisfaction data were collected and compared to a representative cohort. Four groups ran in two clinics. Four to eight parent/infant dyads participated in each group, 24 total dyads. Most participating parents were mothers. Dyads in the group model received 12 hr of contact with Public Health over the year compared to 3 hr in the typical one-on-one model. Participants were younger, more likely to have lower levels of education, and lower household income than the comparison group. Parents reported improvements in parenting experiences following the program. At 4 months, all CenteringParenting babies were vaccinated compared to 95% of babies in the comparison group. The pilot was successfully completed. Additional research is required to examine the effectiveness of CenteringParenting. Data collected provide insight into potential primary outcomes of interest and informs larger, rigorously designed longitudinal studies. © 2016 Wiley Periodicals, Inc.

  19. Establishment of exposure dose assessment laboratory in National Radiation Emergency Medical Center (NREMC)

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jae Ryong; Ha, Wi Ho; Yoon, Seok Won; Han, Eun Ae; Lee, Seung Sook [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2011-10-15

    As unclear industry grown, 432 of the nuclear power plants are operating and 52 of NPPs are under construction currently. Increasing use of radiation or radioisotopes in the field of industry, medical purpose and research such as non-destructive examination, computed tomography and x-ray, etc. constantly. With use of nuclear or radiation has incidence possibility for example the Fukushima NPP incident, the Goiania accident and the Chernobyl Nuclear accident. Also the risk of terror by radioactive material such as Radiological Dispersal Device(RDD) etc. In Korea, since the 'Law on protection of nuclear facilities and countermeasure for radioactive preparedness was enacted in 2003, the Korean institute of Radiological and Medical Sciences(KIRAMS) was established for the radiation emergency medical response in radiological disaster due to nuclear accident, radioactive terror and so on. Especially National Radiation Emergency Medical Center(NREMC) has the duty that is protect citizens from nuclear, radiological accidents or radiological terrors through the emergency medical preparedness. The NREMC was established by the 39-article law on physical protection of nuclear material and facilities and measures for radiological emergencies. Dose assessment or contamination survey should be performed which provide the radiological information for medical response. For this reason, the NREMC establish and re-organized dose assessment system based on the existing dose assessment system of the NREMC recently. The exposure dose could be measured by physical and biological method. With these two methods, we can have conservative dose assessment result. Therefore the NREMC established the exposure dose assessment laboratory which was re-organized laboratory space and introduced specialized equipment for dose assessment. This paper will report the establishment and operation of exposure dose assessment laboratory for radiological emergency response and discuss how to enhance

  20. A method of paralleling computer calculation for two-dimensional kinetic plasma model

    International Nuclear Information System (INIS)

    Brazhnik, V.A.; Demchenko, V.V.; Dem'yanov, V.G.; D'yakov, V.E.; Ol'shanskij, V.V.; Panchenko, V.I.

    1987-01-01

    A method for parallel computer calculation and OSIRIS program complex realizing it and designed for numerical plasma simulation by the macroparticle method are described. The calculation can be carried out either with one or simultaneously with two computers BESM-6, that is provided by some package of interacting programs functioning in every computer. Program interaction in every computer is based on event techniques realized in OS DISPAK. Parallel computer calculation with two BESM-6 computers allows to accelerate the computation 1.5 times

  1. Multiple attachments and group psychotherapy: implications for college counseling centers.

    Science.gov (United States)

    Marmarosh, Cheri L

    2009-10-01

    A large body of literature has supported the application of attachment theory to the understanding of college student development and the process of individual psychotherapy. Despite group treatment being one of the major methods of intervention in college counseling centers, there has been very little research guided by attachment theory that has been applied to the area of group psychotherapy. Many current assessment instruments used in college counseling centers can be supported with attachment theory, and many group therapy interventions are aimed at facilitating secure working models of self, other, and groups. This paper explores the importance of personal and group attachments in group psychotherapy and specifically addresses implications for clinical training and research in university counseling centers.

  2. Pharmacokinetic interaction of enrofloxacin/trimethoprim combination following single-dose intraperitoneal and oral administration in rats.

    Science.gov (United States)

    Choi, Myung-Jin; Yohannes, Sileshi Belew; Lee, Seung-Jin; Damte, Dereje; Kim, Jong-Choon; Suh, Joo-Won; Park, Seung-Chun

    2014-03-01

    The pharmacokinetic interaction of enrofloxacin and trimethoprim was evaluated after single-dose intraperitoneal or oral co-administration in rats. Plasma concentrations of the two drugs were determined by high-performance liquid chromatography. Following intraperitoneal combination, a significant (P trimethoprim, respectively. There was a significant (P trimethoprim. Further study is recommended in other species of animals.

  3. Dose evaluation of narrow-beam

    International Nuclear Information System (INIS)

    Goto, Shinichi

    1999-01-01

    Reliability of the dose from the narrow photon beam becomes more important since the single high-dose rate radiosurgery becoming popular. The dose evaluation for the optimal dose is difficult due to absence of lateral electronic equilibrium. Data necessary for treatment regimen are TMR (tissue maximum ratio), OCR (off center ratio) and S c,p (total scatter factor). The narrow-beam was 10 MV X-ray from Varian Clinac 2100C equipped with cylindrical Fischer collimator CBI system. Detection was performed by Kodak XV-2 film, a PTW natural diamond detector M60003, Scanditronics silicon detector EDD-5 or Fujitec micro-chamber FDC-9.4C. Phantoms were the water equivalent one (PTW, RW3), water one (PTW, MP3 system) and Wellhofer WP600 system. Factors above were actually measured to reveal that in the dose evaluation of narrow photon beam, TMR should be measured by micro-chamber, OCR, by film, and S c,p , by the two. The use of diamond detector was recommended for more precise measurement and evaluation of the dose. The importance of water phantom in the radiosurgery system was also shown. (K.H.)

  4. Automatic Parallelization Tool: Classification of Program Code for Parallel Computing

    Directory of Open Access Journals (Sweden)

    Mustafa Basthikodi

    2016-04-01

    Full Text Available Performance growth of single-core processors has come to a halt in the past decade, but was re-enabled by the introduction of parallelism in processors. Multicore frameworks along with Graphical Processing Units empowered to enhance parallelism broadly. Couples of compilers are updated to developing challenges forsynchronization and threading issues. Appropriate program and algorithm classifications will have advantage to a great extent to the group of software engineers to get opportunities for effective parallelization. In present work we investigated current species for classification of algorithms, in that related work on classification is discussed along with the comparison of issues that challenges the classification. The set of algorithms are chosen which matches the structure with different issues and perform given task. We have tested these algorithms utilizing existing automatic species extraction toolsalong with Bones compiler. We have added functionalities to existing tool, providing a more detailed characterization. The contributions of our work include support for pointer arithmetic, conditional and incremental statements, user defined types, constants and mathematical functions. With this, we can retain significant data which is not captured by original speciesof algorithms. We executed new theories into the device, empowering automatic characterization of program code.

  5. Single daily dosing of antibiotics: importance of in vitro killing rate, serum half-life, and protein binding.

    Science.gov (United States)

    Potel, G; Chau, N P; Pangon, B; Fantin, B; Vallois, J M; Faurisson, F; Carbon, C

    1991-10-01

    The relative importance of pharmacokinetic and pharmacodynamic parameters for the feasibility of a single daily dose (SDD) of antibiotics remains to be established. Therefore, we studied the relationship between in vitro bacteriological parameters (MIC, MBC, and killing rate [KR], defined as the reduction in the inoculum within 3 h), pharmacokinetic parameters (t1/2 and protein binding [PB], and in vivo antibacterial effect of a single antibiotic dose in an experimental rabbit model of Escherichia coli endocarditis. Nine antibiotics were investigated: two aminoglycosides, two quinolones, and five beta-lactams. For each drug, the minimal effective dose (MED) (in milligrams per kilogram) was defined as the lowest dose able to achieve a significant difference (P less than 0.05) of CFU in the vegetations in comparison with controls 24 h after a single intravenous injection. Aminoglycosides and quinolones had the lowest MEDs, followed by beta-lactams. Univariate regression analysis showed that KR was the major determinant of MED. A stepwise regression analysis showed that t1/2 significantly improved the predictive value of KR, while PB, MIC, and MBC did not. The final equation was MED = 1,586-238 KR-297 t1/2 (r = 0.90, P = 0.01). We concluded that the pharmacodynamic parameters (especially the high KR) of aminoglycosides and quinolones explained their low MEDs and might allow SDD. In contrast, the low KR of beta-lactams emphasized the critical importance of a long t1/2, as for ceftriaxone, allowing the use of this beta-lactam alone in SDD.

  6. A randomized trial of three single - dose radiation therapy regimens in the treatment of metastatic bone pain

    International Nuclear Information System (INIS)

    Jeremic, Branislav; Shibamoto, Yuta; Acimovic, Ljubisa; Milicic, Biljana; Milisavljevic, Slobodan; Nikolic, Nebojsa; Aleksandrovic, Jasna; Igrutinovic, Ivan

    1998-01-01

    Purpose: To investigate efficacy of three single dose radiation therapy (RT) regimens in the treatment of painful bone metastasis. Material and Methods: Patient self-assessment by using pain chart enabled evaluation of response to treatment that consisted of either one of the three single fractions of 4 Gy (group I; n = 109), 6 Gy (group II; n = 108), or 8 Gy (group III; n = 110). Results: Patients in groups II and III had higher complete response rate than those in group I, but not significantly, and with no difference between group II and III. However, both patients in group II (73%) and group III (78%) had significantly higher overall response rates when compared to those observed in group I (59%) (I vs II, p = 0.025; I vs III, p = 0.0019), and with no difference between groups II and III (p 0.39). Patients in group III had shortest time to the occurrence of any pain relief which was significantly better than those observed in group I (Welch's t-test, p = 0.012), with no difference between group I and II and group II and III, respectively. There was no difference between the three treatment groups in duration of response and retreatment rate. No effect of histology or metastatic site treated was found. No pathological fractures or spinal cord compressions were observed during the 8 weeks post-RT. Conclusion: Results of this study seem to confirm that 8 Gy could be considered as probably 'lowest' optimal single fraction RT in the treatment of painful bone metastasis, although single fraction RT of 4 Gy should not be easily discarded due to its applicability in specific cases. Since single fraction RT of 6 Gy achieved results not different from that obtained with 8 Gy, further studies are warranted in order to get more informations about 'lowest' optimal single fraction RT in the treatment of painful bone metastasis

  7. A study on mice exposure dose for low-dose gamma-irradiation using glass dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Sung Jin; Kim, Hyo Jin; Kim, Hyun; Jeong, Dong Hyeok; Son, Tae Gen; Kim, Jung Ki; Yang, Kwang Mo; Kang, Yeong Rok [Research Center, Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of); Nam, Sang Hee [Dept. of Biomedical Engineering, Inje University, Gimhae (Korea, Republic of)

    2015-12-15

    The low dose radiation is done for a long period, thus researchers have to know the exact dose distribution for the irradiated mouse. This research has been conducted in order to find out methods in transmitting an exact dose to mouse in a mouse irradiation experiment carried out using {sup 137}C{sub s} irradiation equipment installed in the DIRAMS (Dongnam Institution of Radiological and Medical Sciences) research center. We developed a single mouse housing cage and shelf with adjustable geometric factors such as distance and angle from collimator. The measurement of irradiated dose showed a maximal 42% difference of absorbed dose from the desired dose in the conventional irradiation system, whereas only 6% difference of the absorbed dose was measured in the self-developed mouse apartment system. In addition, multi mice housing showed much difference of the absorbed dose in between head and body, compared to single mouse housing in the conventional irradiation system. This research may allow further research about biological effect assessment for the low dose irradiation using the self-developed mouse apartment to provide more exact doses which it tries to transmit, and to have more reliability for the biological analysis results.

  8. Distance-two interpolation for parallel algebraic multigrid

    International Nuclear Information System (INIS)

    Sterck, H de; Falgout, R D; Nolting, J W; Yang, U M

    2007-01-01

    In this paper we study the use of long distance interpolation methods with the low complexity coarsening algorithm PMIS. AMG performance and scalability is compared for classical as well as long distance interpolation methods on parallel computers. It is shown that the increased interpolation accuracy largely restores the scalability of AMG convergence factors for PMIS-coarsened grids, and in combination with complexity reducing methods, such as interpolation truncation, one obtains a class of parallel AMG methods that enjoy excellent scalability properties on large parallel computers

  9. Implementation of the AAPM Task Group 21 protocol by the Radiological Physics Center and its implications

    International Nuclear Information System (INIS)

    Gastorf, R.J.; Hanson, W.F.; Shalek, R.J.; Berkley, L.W.

    1984-01-01

    The Radiation Therapy Committee of the American Association of Physicists in Medicine appointed Task Group 21 to write a new protocol for the calibration of high-energy photon and electron therapy beams. This protocol updates the physical parameters used in the calculations and is intended to account for differences in ionization chamber design and some differences between phantom materials that were not considered in previous protocols. This paper discusses how the Radiological Physics Center (RPC) intends to implement the new protocol, the changes required in the RPC calibration techniques, and the magnitude of the change in the RPC calculations of absorbed dose resulting from the implementation of the new protocol. Although the change in the RPC absorbed-dose calculations will be only 0%-2% over the range of photon and electron energies of interest, some institutions using specific dosimetry systems may find their absorbed-dose calculations changing by 4% or more

  10. Effectiveness of single dose rifampicin in preventing leprosy in close contacts of patients with newly diagnosed leprosy: cluster randomised controlled trial

    NARCIS (Netherlands)

    Moet, F. Johannes; Pahan, David; Oskam, Linda; Richardus, Jan H.; van Brakel, Wim H.; Klatser, Paul R.; Saunderson, Paul R.; Smith, W. Cairns S.; Withington, Steve G.; Richardus, Jan Hendrik; Schuring, Ron P.; Faber, Roel; Borsboom, Gerard J. J. M.

    2008-01-01

    OBJECTIVE: To determine the effectiveness of chemoprophylaxis using a single dose of rifampicin to prevent leprosy in close contacts. DESIGN: Single centre, double blind, cluster randomised, placebo controlled trial. SETTING: Leprosy control programme in two districts of northwest Bangladesh with a

  11. Analysis of complications in a prospective randomized trial comparing two brachytherapy low dose rates in cervical carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-07-30

    The analysis of complications in a prospective randomized trial comparing two preoperative brachytherapy low-dose rates in early stage cervical cancer is presented. The objective of this trial was to determine the benefits, if any, of the higher-dose rate within the therapeutic aresenal for this patient population, in terms of survival, local control, and complications. Overall survival, 85% at 2 years and local control, 93% at 2 years, were similarly distributed between the two groups. Regardless of their nature and severity, 139 and 175 complications were observed among 63% and 75% of patients, in the 0.4 and 0.8 Gy/h dose rate groups respectively. Gynecologic and urinary complications were the most frequent (38% and 28% of all complications), followed by vascular (15%), digestive (10%), nervous (5%), and cutaneous (5%). A total of 14 and 17 severe complications (Grade 3) were observed in 7% and 13% of patients, respectively in the 0.4 and 0.8 Gy/h dose rate groups (p = 0.12) Nonparametric survival methods used to compare the time to the first complication did not show a significant difference between the two groups: 62% and 72% at 2 years (p = 0.27). When the first complication and its evolution were considered (early complications), the prevalence of complications was not significantly different between the two groups: 28% vs. 34% at 2 years (p = 0.31). In this prospective trial, patients were regularly followed-up and complications of varying nature and severity were observed in succession during follow-up. When successive complications and their evolution were taken into account, the prevalence of complications was significantly greater in the higher-dose rate group: 30% vs 45% at 2 years (p = 0.03). The results of this trial showed that long-term effects of treatment, when represented by prevalence of complications over time, were more frequent in the higher dose rate group. 33 refs., 3 figs., 5 tabs.

  12. Single- and multiple-dose pharmacokinetics, pharmacodynamics, and safety of apixaban in healthy Chinese subjects

    Directory of Open Access Journals (Sweden)

    Cui Y

    2013-12-01

    Full Text Available Yimin Cui,1 Yan Song,2 Jessie Wang,2 Zhigang Yu,2 Alan Schuster,2 Yu Chen Barrett,2 Charles Frost2 1Peking University First Hospital, Beijing, People's Republic of China; 2Bristol-Myers Squibb, Princeton, NJ, USA Background: The pharmacokinetics (PK, pharmacodynamics (PD, and safety of apixaban were assessed in healthy Chinese subjects in this randomized, placebo-controlled, double-blind, single-sequence, single- and multiple-dose study. Subjects and methods: Eighteen subjects 18–45 years of age were randomly assigned (2:1 ratio to receive apixaban or matched placebo. Subjects received a single 10 mg dose of apixaban or placebo on day 1, followed by 10 mg apixaban or placebo twice daily for 6 days (days 4–9. The PK and PD of apixaban were assessed by collecting plasma samples for 72 hours following the dose on day 1 and the morning dose on day 9, and measuring apixaban concentration and anti-Xa activity. Safety was assessed via physical examinations, vital sign measurements, electrocardiograms, and clinical laboratory evaluations. Results: PK analysis showed similar characteristics of apixaban after single and multiple doses, including a median time to maximum concentration of ~3 hours, mean elimination half-life of ~11 hours, and renal clearance of ~1.2 L/hour. The accumulation index was 1.7, consistent with twice-daily dosing and the observed elimination half-life. Single-dose data predict multiple-dose PK, therefore apixaban PK are time-independent. The relationship between anti-Xa activity and plasma apixaban concentrations appears to be linear. Apixaban was safe and well tolerated, with no bleeding-related adverse events reported. Conclusion: Apixaban was safe and well tolerated in healthy Chinese subjects. Apixaban PK and PD were predictable and consistent with findings from previous studies in Asian and non-Asian subjects. The administration of apixaban does not require any dose modification based on race. Keywords: apixaban, oral

  13. Parallel Computing Characteristics of CUPID code under MPI and Hybrid environment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Ryong; Yoon, Han Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Jeon, Byoung Jin; Choi, Hyoung Gwon [Seoul National Univ. of Science and Technology, Seoul (Korea, Republic of)

    2014-05-15

    In this paper, a characteristic of parallel algorithm is presented for solving an elliptic type equation of CUPID via domain decomposition method using the MPI and the parallel performance is estimated in terms of a scalability which shows the speedup ratio. In addition, the time-consuming pattern of major subroutines is studied. Two different grid systems are taken into account: 40,000 meshes for coarse system and 320,000 meshes for fine system. Since the matrix of the CUPID code differs according to whether the flow is single-phase or two-phase, the effect of matrix shape is evaluated. Finally, the effect of the preconditioner for matrix solver is also investigated. Finally, the hybrid (OpenMP+MPI) parallel algorithm is introduced and discussed in detail for solving pressure solver. Component-scale thermal-hydraulics code, CUPID has been developed for two-phase flow analysis, which adopts a three-dimensional, transient, three-field model, and parallelized to fulfill a recent demand for long-transient and highly resolved multi-phase flow behavior. In this study, the parallel performance of the CUPID code was investigated in terms of scalability. The CUPID code was parallelized with domain decomposition method. The MPI library was adopted to communicate the information at the neighboring domain. For managing the sparse matrix effectively, the CSR storage format is used. To take into account the characteristics of the pressure matrix which turns to be asymmetric for two-phase flow, both single-phase and two-phase calculations were run. In addition, the effect of the matrix size and preconditioning was also investigated. The fine mesh calculation shows better scalability than the coarse mesh because the number of coarse mesh does not need to decompose the computational domain excessively. The fine mesh can be present good scalability when dividing geometry with considering the ratio between computation and communication time. For a given mesh, single-phase flow

  14. Single-dose pharmacokinetic study comparing the pharmacokinetics of recombinant human chorionic gonadotropin in healthy Japanese and Caucasian women and recombinant human chorionic gonadotropin and urinary human chorionic gonadotropin in healthy Japanese women.

    Science.gov (United States)

    Bagchus, Wilhelmina; Wolna, Peter; Uhl, Wolfgang

    2018-01-01

    Recombinant hCG (r-hCG) was approved in Japan in 2016. As a prerequisite for a Phase III study in Japan related to this approval, the pharmacokinetic (PK) profile of r-hCG was investigated. An open-label, partly randomized, single-center, single-dose, group-comparison, Phase I PK-bridging study was done that compared a single 250 μg dose of r-hCG with a single 5000 IU dose of urinary hCG (u-hCG) in healthy Japanese women, as well as comparing a single 250 μg dose of r-hCG in Japanese and Caucasian women. The Japanese participants were randomized 1:1 to receive either r-hCG or u-hCG, while the Caucasian participants were weight-matched to the Japanese participants who were receiving r-hCG in a 1:1 fashion. The primary PK parameters were the area under the serum concentration-time curve from time 0 extrapolated to infinity (AUC 0-∞ ) and the maximum serum concentration (C max ). The mean serum hCG concentration-time profiles of r-hCG in the Japanese and Caucasian participants were a similar shape, but the level of overall exposure was ~20% lower in the Japanese participants. For the Japanese participants, r-hCG resulted in an 11% lower C max but a 19% higher AUC 0-∞ compared with u-hCG. No new safety signal was identified. This study cannot exclude a potential difference in the PK profile of r-hCG between Japanese and Caucasian participants. However, this study does not indicate that there are clinically relevant differences in the serum PK of r-hCG and u-hCG in the Japanese participants.

  15. Management of urinary tract infections in pregnancy: a review with comments on single dose therapy.

    Science.gov (United States)

    Zinner, S H

    1992-01-01

    Most investigators agree that the adverse effects of urinary tract infections in pregnancy can be abrogated by effective early detection and treatment. However, the optimal methods for screening and treatment remain controversial. Although single-dose therapy has not been applied to pregnant women with acute pyelonephritis, most but not all studies which have compared single-dose with longer courses of beta-lactam or other antibiotics in pregnant asymptomatic bacteriuric women have shown no differences in outcome. This paper reviews recent trials of single-dose treatment of bacteriuria in pregnant women.

  16. Long-term Dose Stability of OnabotulinumtoxinA Injection for Adductor Spasmodic Dysphonia: A 19-Year Single Institution Experience

    Directory of Open Access Journals (Sweden)

    Paul Paddle

    2017-11-01

    Full Text Available ObjectivesAdductor spasmodic dysphonia (AdSD is a focal dystonia predominantly involving the laryngeal adductor muscles. AdSD is reported to be a largely non-progressive neurological disorder, though fluctuations in symptom severity do occur. Repeated laryngeal onabotulinumtoxinA (BTX-A injections are the primary management for AdSD. A number of studies have demonstrated long-term dose stability as evidence of this long-term disease stability.MethodsA retrospective review was performed on all patients undergoing BTX-A injections for AdSD from April 1994 to September 2013 by a single laryngologist at a tertiary referral laryngology center. Patient demographics, injection doses, use of diazepam and/or lidocaine, and self-reported vocal function were recorded. Multiple linear regression analyses were performed.Results83 patients underwent a total of 1,168 injections over 19 years. The mean starting dose was 2.35 MU (0.79 SD. The mean long-term dose was 2.36 MU (0.79 SD. After adjusting for confounders, the change in the relative dose of BTX-A, with every year elapsed since initial dose was 0.13% (95% confidence interval −0.31 to 0.57%, p = 0.568.ConclusionBTX-A dose is stable over time in our large cohort of patients treated with bilateral thyroarytenoid injections for AdSD.

  17. Splenic Artery Embolization in Blunt Trauma: A Single-Center Retrospective Comparison of the Use of Gelatin Sponge Versus Coils.

    Science.gov (United States)

    Rasuli, Pasteur; Moosavi, Bardia; French, Gordon J; Petrcich, William; Hammond, Ian

    2017-12-01

    The purpose of this study was to compare the efficacy of gelatin sponge with that of coils for splenic artery embolization in the treatment of blunt splenic injury. A single-center retrospective review was performed with the records of 63 patients (45 men, 18 women; mean age, 45.5 years; range, 16-84 years) with blunt splenic injury treated at a tertiary care trauma center by splenic artery embolization with gelatin sponge (n = 30 patients) or metallic coils (n = 33 patients) between 2005 and 2014. The two groups had comparable median American Association for the Surgery of Trauma grades of IV and comparable angiographic appearances regarding active extravasation and pseudoaneurysm formation at preembolization splenic arteriography (p = 0.32). Clinical outcomes and procedure-related outcomes were evaluated. The success rates were similar in the two groups: splenic artery embolization failed in 6.6% (2/30) of patients in the gelatin sponge group and 12.1% (4/33) in the coil embolization group (p = 0.45; 95% CI, -30.1% to 19.2%). Major complications occurred in six patients (20.0%) in the gelatin sponge group and in six patients (18.1%) in the coil group (p = 0.85; 95% CI, -23.0% to 26.6%). Minor complications occurred in three patients (10.0%) in the gelatin sponge group and seven patients (21.2%) in the coil group (p = 0.21; 95% CI, -35.4% to 14.0%). Procedure time was significantly shorter in the gelatin sponge group (median, 32 minutes; interquartile range, 18-48 minutes) than in the coil group (median, 53 minutes; interquartile range, 30-76 minutes) (p = 0.01). Splenic artery embolization with gelatin sponge appears to be as effective and as safe as coil embolization and can be completed in a shorter time.

  18. Scientist, Single Cell Analysis Facility | Center for Cancer Research

    Science.gov (United States)

    The Cancer Research Technology Program (CRTP) develops and implements emerging technology, cancer biology expertise and research capabilities to accomplish NCI research objectives.  The CRTP is an outward-facing, multi-disciplinary hub purposed to enable the external cancer research community and provides dedicated support to NCI’s intramural Center for Cancer Research (CCR).  The dedicated units provide electron microscopy, protein characterization, protein expression, optical microscopy and nextGen sequencing. These research efforts are an integral part of CCR at the Frederick National Laboratory for Cancer Research (FNLCR).  CRTP scientists also work collaboratively with intramural NCI investigators to provide research technologies and expertise. KEY ROLES AND RESPONSIBILITIES We are seeking a highly motivated Scientist II to join the newly established Single Cell Analysis Facility (SCAF) of the Center for Cancer Research (CCR) at NCI. The SCAF will house state of the art single cell sequencing technologies including 10xGenomics Chromium, BD Genomics Rhapsody, DEPPArray, and other emerging single cell technologies. The Scientist: Will interact with close to 200 laboratories within the CCR to design and carry out single cell experiments for cancer research Will work on single cell isolation/preparation from various tissues and cells and related NexGen sequencing library preparation Is expected to author publications in peer reviewed scientific journals

  19. A simple image-reject mixer based on two parallel phase modulators

    Science.gov (United States)

    Hu, Dapeng; Zhao, Shanghong; Zhu, Zihang; Li, Xuan; Qu, Kun; Lin, Tao; Zhang, Kun

    2018-02-01

    A simple photonic microwave image-reject mixer (IRM) using two parallel phase modulators is proposed. First, a photonic microwave mixer with phase shift ability is achieved using two parallel phase modulators (PMs), an optical bandpass filter, three polarization controllers, three polarization beam splitters and two balanced photodetectors. At the output of the mixer, two frequency downconverted signals with tunable frequency difference can be obtained. By adjusting the phase difference as 90° and utilizing an electrical 90° hybrid, the useless components can be eliminated, and the image reject operation is realized. The key advantage of the proposed scheme is the usage of PM, which avoid the DC bias shifting problem and make the system simple and stable. A simulation is performed to verify the proposed scheme, a relative - 90° or 90° phase shift can be obtained between the two output ports of the photonic microwave mixer, at the output of the IRM, 60 dB image-reject ratio is obtained.

  20. Is single-dose fosfomycin trometamol a good alternative for asymptomatic bacteriuria in the second trimesterof pregnancy?

    Science.gov (United States)

    Bayrak, Omer; Cimentepe, Ersin; Inegöl, Ilknur; Atmaca, Ali Fuat; Duvan, Candan Iltemir; Koç, Akif; Turhan, Nilgün Oztürk

    2007-05-01

    Untreated asymptomatic bacteriuria has been associated with acute pyelonephritis, which may have a role in many maternal and fetal complications. Acute pyelonephritis in pregnancy is related to anemia, septicemia, transient renal dysfunction, and pulmonary insufficiency. A randomized study was conducted to assess the clinical and microbiological efficacy of a single dose of fosfomycin trometamol for the treatment of asymptomatic bacteriuria in the second trimester of pregnancy compared with a 5-day regimen of cefuroxime axetyl. Forty-four women received fosfomycin trometamol and 40 women received cefuroxime axetyl. There were no statistically significant differences between both groups regarding the mean age and mean duration of pregnancy. Therapeutic success was achieved in 93.2% of the patients treated with fosfomycin trometamol vs 95% of those treated with cefuroxime axetyl. A single dose of fosfomycin trometamol is a safe and effective alternative in the treatment of asymptomatic urinary tract infections in the second trimester of pregnancy.