WorldWideScience

Sample records for paper-thinned diaphragm ct

  1. Paper-thinned diaphragm: CT sign of diaphragmatic eventration

    International Nuclear Information System (INIS)

    Im, Jung Gi; Han, Man Chung; Kim, Chu Wan; Shim, Young Soo

    1990-01-01

    CT findings of total left hemidiaphragmatic eventration in two adult patients are described. Chest radiograph showed elevated left hemidiaphragm and left hilum. Paper-thinned muscular portion of the diseased diaphragm was clearly demonstrated with CT scan. With demonstration of paper-thinned diaphragm by CT scan, differentiation of the diaphragmatic eventration from recent onset phrenic nerve paralysis by tumor invasion or from post-traumatic diaphragmatic hernia can be made

  2. Paper-thinned diaphragm: CT sign of diaphragmatic eventration

    Energy Technology Data Exchange (ETDEWEB)

    Im, Jung Gi; Han, Man Chung; Kim, Chu Wan; Shim, Young Soo [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    1990-10-15

    CT findings of total left hemidiaphragmatic eventration in two adult patients are described. Chest radiograph showed elevated left hemidiaphragm and left hilum. Paper-thinned muscular portion of the diseased diaphragm was clearly demonstrated with CT scan. With demonstration of paper-thinned diaphragm by CT scan, differentiation of the diaphragmatic eventration from recent onset phrenic nerve paralysis by tumor invasion or from post-traumatic diaphragmatic hernia can be made.

  3. Traumatic rupture of the diaphragm: CT findings

    International Nuclear Information System (INIS)

    Cho, Sung Tae; Kim, Sung Jin; Cha, Sang Hoon; Park, Kil Sun; Kim, Jin Hee; Yim, Se Hwan

    1995-01-01

    The aim of this study was to assess the clinical utility of the known CT signs of the traumatic rupture of the diaphragm. CT scans and chest radiographs were retrospectively reviewed in 13 patients who had diaphragmatic rupture confirmed by surgery. On chest radiographs the elevation of the diaphragm was evaluated. On CT, 1) discontinuity of the diaphragm, 2) lack of depiction of the diaphragm surrounding the herniated intraabdominal organs (absent diaphragm sign), and 3) fat seen lateral to the diaphragm (fat sign) were evaluated. Chest radiographs showed the elevation of the diaphragm in 11 patients (85%). CT scan showed absent diaphragm sign in 11 patients (85%), discontinuity of the diaphragm in 8 (62%), and fat sign in 7 (54%). All of 12 patients who had the left diaphragmatic rupture had one or more of the above findings. Discontinuity of the diaphragm, absent diaphragm sign, and fat sign may be helpful CT findings in the diagnosis of the traumatic rupture of the left diaphragm

  4. Four-Dimensional CT of the Diaphragm in Children: Initial Experience

    Science.gov (United States)

    2018-01-01

    Objective To evaluate the technical feasibility of four-dimensional (4D) CT for the functional evaluation of the pediatric diaphragm. Materials and Methods In 22 consecutive children (median age 3.5 months, age range 3 days–3 years), 4D CT was performed to assess diaphragm motion. Diaphragm abnormalities were qualitatively evaluated and diaphragm motion was quantitatively measured on 4D CT. Lung density changes between peak inspiration and expiration were measured in the basal lung parenchyma. The diaphragm motions and lung density changes measured on 4D CT were compared between various diaphragm conditions. In 11 of the 22 children, chest sonography was available for comparison. Results Four-dimensional CT demonstrated normal diaphragm (n = 8), paralysis (n = 10), eventration (n = 3), and diffusely decreased motion (n = 1). Chest sonography demonstrated normal diaphragm (n = 2), paralysis (n = 6), eventration (n = 2), and right pleural effusion (n = 1). The sonographic findings were concordant with the 4D CT findings in 90.9% (10/11) of the patients. In diaphragm paralysis, the affected diaphragm motion was significantly decreased compared with the contralateral normal diaphragm motion (−1.1 ± 2.2 mm vs. 7.6 ± 3.8 mm, p = 0.005). The normal diaphragms showed significantly greater motion than the paralyzed diaphragms (4.5 ± 2.1 mm vs. −1.1 ± 2.2 mm, p Hounsfield units [HU] vs. 180 ± 71 HU, p = 0.03), while no significant differences were found between the normal diaphragms and the paralyzed diaphragms (136 ± 66 HU vs. 89 ± 73 HU, p = 0.1) or between the normal diaphragms and the contralateral normal diaphragms in paralysis (136 ± 66 HU vs. 180 ± 71 HU, p = 0.1). Conclusion The functional evaluation of the pediatric diaphragm is feasible with 4D CT in select children. PMID:29354007

  5. Fully automatic algorithm for segmenting full human diaphragm in non-contrast CT Images

    Science.gov (United States)

    Karami, Elham; Gaede, Stewart; Lee, Ting-Yim; Samani, Abbas

    2015-03-01

    The diaphragm is a sheet of muscle which separates the thorax from the abdomen and it acts as the most important muscle of the respiratory system. As such, an accurate segmentation of the diaphragm, not only provides key information for functional analysis of the respiratory system, but also can be used for locating other abdominal organs such as the liver. However, diaphragm segmentation is extremely challenging in non-contrast CT images due to the diaphragm's similar appearance to other abdominal organs. In this paper, we present a fully automatic algorithm for diaphragm segmentation in non-contrast CT images. The method is mainly based on a priori knowledge about the human diaphragm anatomy. The diaphragm domes are in contact with the lungs and the heart while its circumference runs along the lumbar vertebrae of the spine as well as the inferior border of the ribs and sternum. As such, the diaphragm can be delineated by segmentation of these organs followed by connecting relevant parts of their outline properly. More specifically, the bottom surface of the lungs and heart, the spine borders and the ribs are delineated, leading to a set of scattered points which represent the diaphragm's geometry. Next, a B-spline filter is used to find the smoothest surface which pass through these points. This algorithm was tested on a noncontrast CT image of a lung cancer patient. The results indicate that there is an average Hausdorff distance of 2.96 mm between the automatic and manually segmented diaphragms which implies a favourable accuracy.

  6. Free-Standing β-Ga2O3 Thin Diaphragms

    Science.gov (United States)

    Zheng, Xu-Qian; Lee, Jaesung; Rafique, Subrina; Han, Lu; Zorman, Christian A.; Zhao, Hongping; Feng, Philip X.-L.

    2018-02-01

    Free-standing, very thin, single-crystal β-gallium oxide (β-Ga2O3) diaphragms have been constructed and their dynamical mechanical properties characterized by noncontact, noninvasive optical measurements harnessing the multimode nanomechanical resonances of these suspended nanostructures. We synthesized single-crystal β-Ga2O3 using low-pressure chemical vapor deposition (LPCVD) on a 3C-SiC epilayer grown on Si substrate at temperature of 950°C for 1.5 h. The synthesized single-crystal nanoflakes had widths of ˜ 2 μm to 30 μm and thicknesses of ˜ 20 nm to 140 nm, from which we fabricated free-standing circular drumhead β-Ga2O3 diaphragms with thicknesses of ˜ 23 nm to 73 nm and diameters of ˜ 3.2 μm and ˜ 5.2 μm using a dry stamp-transfer technique. Based on measurements of multiple flexural-mode mechanical resonances using ultrasensitive laser interferometric detection and performing thermal annealing at 250°C for 1.5 h, we quantified the effects of annealing and adsorption of atmospheric gas molecules on the resonant characteristics of the diaphragms. Furthermore, we studied the effects of structural nonidealities on these free-standing β-Ga2O3 nanoscale diaphragms. We present extensive characterization of the mechanical and optical properties of free-standing β-Ga2O3 diaphragms, paving the way for realization of resonant transducers using such nanomechanical structures for use in applications including gas sensing and ultraviolet radiation detection.

  7. Emphysema quantification from CT scans using novel application of diaphragm curvature estimation: comparison with standard quantification methods and pulmonary function data

    Science.gov (United States)

    Keller, Brad M.; Reeves, Anthony P.; Yankelevitz, David F.; Henschke, Claudia I.; Barr, R. Graham

    2009-02-01

    Emphysema is a disease of the lungs that destroys the alveolar air sacs and induces long-term respiratory dysfunction. CT scans allow for the imaging of the anatomical basis of emphysema and quantification of the underlying disease state. Several measures have been introduced for the quantification emphysema directly from CT data; most,however, are based on the analysis of density information provided by the CT scans, which vary by scanner and can be hard to standardize across sites and time. Given that one of the anatomical variations associated with the progression of emphysema is the flatting of the diaphragm due to the loss of elasticity in the lung parenchyma, curvature analysis of the diaphragm would provide information about emphysema from CT. Therefore, we propose a new, non-density based measure of the curvature of the diaphragm that would allow for further quantification methods in a robust manner. To evaluate the new method, 24 whole-lung scans were analyzed using the ratios of the lung height and diaphragm width to diaphragm height as curvature estimates as well as using the emphysema index as comparison. Pearson correlation coefficients showed a strong trend of several of the proposed diaphragm curvature measures to have higher correlations, of up to r=0.57, with DLCO% and VA than did the emphysema index. Furthermore, we found emphysema index to have only a 0.27 correlation to the proposed measures, indicating that the proposed measures evaluate different aspects of the disease.

  8. Thermal Stresses Analysis and Optimized TTP Processes to Achieved CNT-Based Diaphragm for Thin Panel Speakers

    Directory of Open Access Journals (Sweden)

    Feng-Min Lai

    2016-01-01

    Full Text Available Industrial companies popularly used the powder coating, classing, and thermal transfer printing (TTP technique to avoid oxidation on the metallic surface and stiffened speaker diaphragm. This study developed a TTP technique to fabricate a carbon nanotubes (CNTs stiffened speaker diaphragm for thin panel speaker. The self-developed TTP stiffening technique did not require a high curing temperature that decreased the mechanical property of CNTs. In addition to increasing the stiffness of diaphragm substrate, this technique alleviated the middle and high frequency attenuation associated with the smoothing sound pressure curve of thin panel speaker. The advantage of TTP technique is less harmful to the ecology, but it causes thermal residual stresses and some unstable connections between printed plates. Thus, this study used the numerical analysis software (ANSYS to analyze the stress and thermal of work piece which have not delaminated problems in transfer interface. The Taguchi quality engineering method was applied to identify the optimal manufacturing parameters. Finally, the optimal manufacturing parameters were employed to fabricate a CNT-based diaphragm, which was then assembled onto a speaker. The result indicated that the CNT-based diaphragm improved the sound pressure curve smoothness of the speaker, which produced a minimum high frequency dip difference (ΔdB value.

  9. DOUBLE BOSS SCULPTURED DIAPHRAGM EMPLOYED PIEZORESISTIVE MEMS PRESSURE SENSOR WITH SILICON-ON-INSULATOR (SOI

    Directory of Open Access Journals (Sweden)

    D. SINDHANAISELVI

    2017-07-01

    Full Text Available This paper presents the detailed study on the measurement of low pressure sensor using double boss sculptured diaphragm of piezoresistive type with MEMS technology in flash flood level measurement. The MEMS based very thin diaphragms to sense the low pressure is analyzed by introducing supports to achieve linearity. The simulation results obtained from Intellisuite MEMS CAD design tool show that very thin diaphragms with rigid centre or boss give acceptable linearity. Further investigations on very thin diaphragms embedded with piezoresistor for low pressure measurement show that it is essential to analyse the piezoresistor placement and size of piezoresistor to achieve good sensitivity. A modified analytical modelling developed in this study for double boss sculptured diaphragm results were compared with simulated results. Further the enhancement of sensitivity is analyzed using non uniform thickness diaphragm and Silicon-On-Insulator (SOI technique. The simulation results indicate that the double boss square sculptured diaphragm with SOI layer using 0.85μm thickness yields the higher voltage sensitivity, acceptable linearity with Small Scale Deflection.

  10. Dependent lung opacity at thin-section CT: evaluation by spirometrically-gated CT of the influence of lung volume

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Yoon, Seong Kuk; Sohn, Choon Hee; Choi, Pil Jo; Webb, W. Richard

    2002-01-01

    To evaluate the influence of lung volume on dependent lung opacity seen at thin-section CT. In thirteen healthy volunteers, thin-section CT scans were performed at three levels (upper, mid, and lower portion of the lung) and at different lung volumes (10, 30, 50, and 100% vital capacity), using spirometric gated CT. Using a three-point scale, two radiologists determined whether dependent opacity was present, and estimated its degree. Regional lung attenuation at a level 2 cm above the diaphragm was determined using semiautomatic segmentation, and the diameter of a branch of the right lower posterior basal segmental artery was measured at each different vital capacity. At all three anatomic levels, dependent opacity occurred significantly more often at lower vital capacities (10, 30%) than at 100% vital capacity (p = 0.001). Visually estimated dependent opacity was significantly related to regional lung attenuation (p < 0.0001), which in dependent areas progressively increased as vital capacity decreased (p < 0.0001). The presence of dependent opacity and regional lung attenuation of a dependent area correlated significantly with increased diameter of a segmental arterial branch (r = 0.493 and p = 0.0002; r = 0.486 and p 0.0003, respectively). Visual estimation and CT measurements of dependent opacity obtained by semiautomatic segmentation are significantly influenced by lung volume and are related to vascular diameter

  11. Crura sign: differentiation between traumatic rupture of the diaphragm and nontraumatic diaphragmatic elevation on CT

    International Nuclear Information System (INIS)

    Kim, Sung Jin; Han, Hae Ja; Kim, Wang Jung; Youk, Yong Soo; Han, Gi Seok; Cha, Sang Hoon; Park, Kil Sun; Kim, Dae Young

    1997-01-01

    To evaluate whether in patients with diffuse evaluation of a hemidiaphragm on chest radiographs, the apparence of the crura on CT might be helpful in differentiating between traumatic rupture of the diaphragm (TRD) and nontraumatic causes such as diaphragmatic palsy or diffuse diaphragmatic eventration. Among patients with diffuse elevations of a hemidiaphragm on chest radiograph, 27 who had patients undergone CT scans were retrospectively reviewed. Twelve patients had surgically proven TRD, and 15 had nontraumatic elevation of a hemidiaphragm such as diaphragmatic palsy or diffuse diaphragmatic eventration. Under the hypothesis that the affected crus is markedly thinner than the normal side in nontraumatic elevation but is normal in TRD ('crura sign', we optically assessed without measurement the thickness of both crura. In all patients with TRD, the thickness of the affected crus was similar to that of the contralateral side. In all patients with nontraumatic causes, however, the crus of the elevated hemidiaphragm was markedly thinner than that of the normal side. The 'crura sign' may be useful additional CT finding of traumatic rupture the diaphragm

  12. Miniature all-silica optical fiber pressure sensor with an ultrathin uniform diaphragm.

    Science.gov (United States)

    Wang, Wenhui; Wu, Nan; Tian, Ye; Niezrecki, Christopher; Wang, Xingwei

    2010-04-26

    This paper presents an all-silica miniature optical fiber pressure/acoustic sensor based on the Fabry-Perot (FP) interferometric principle. The endface of the etched optical fiber tip and silica thin diaphragm on it form the FP structure. The uniform and thin silica diaphragm was fabricated by etching away the silicon substrate from a commercial silicon wafer that has a thermal oxide layer. The thin film was directly thermally bonded to the endface of the optical fiber thus creating the Fabry-Perot cavity. Thin films with a thickness from 1microm to 3microm have been bonded successfully. The sensor shows good linearity and hysteresis during measurement. A sensor with 0.75 microm-thick diaphragm thinned by post silica etching was demonstrated to have a sensitivity of 11 nm/kPa. The new sensor has great potential to be used as a non-intrusive pressure sensor in a variety of sensing applications.

  13. Three-dimensional quadratic modeling and quantitative evaluation of the diaphragm on a volumetric CT scan in patients with chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Yongjun [School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 34138 (Korea, Republic of); Bae, Jangpyo [Interdisciplinary Program, Bioengineering Major, Graduate School, Seoul National University, Seoul 08826 (Korea, Republic of); Kim, Namkug, E-mail: namkugkim@gmail.com [Department of Convergence Medicine, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505 (Korea, Republic of); Park, Joo-Young; Lee, Sang Min; Seo, Joon Beom [Department of Radiology, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505 (Korea, Republic of)

    2016-07-15

    Purpose: In patients with chronic obstructive pulmonary disease (COPD), diaphragm function may deteriorate due to reduced muscle fiber length. Quantitative analysis of the morphology of the diaphragm is therefore important. In the authors current study, they propose a diaphragm segmentation method for COPD patients that uses volumetric chest computed tomography (CT) data, and they provide a quantitative analysis of the diaphragmatic dimensions. Methods: Volumetric CT data were obtained from 30 COPD patients and 10 normal control patients using a 16-row multidetector CT scanner (Siemens Sensation 16) with 0.75-mm collimation. Diaphragm segmentation using 3D ray projections on the lower surface of the lungs was performed to identify the draft diaphragmatic lung surface, which was modeled using quadratic 3D surface fitting and robust regression in order to minimize the effects of segmentation error and parameterize diaphragm morphology. This result was visually evaluated by an expert thoracic radiologist. To take into consideration the shape features of the diaphragm, several quantification parameters—including the shape index on the apex (SIA) (which was computed using gradient set to 0), principal curvatures on the apex on the fitted diaphragm surface (CA), the height between the apex and the base plane (H), the diaphragm lengths along the x-, y-, and z-axes (XL, YL, ZL), quadratic-fitted diaphragm lengths on the z-axis (FZL), average curvature (C), and surface area (SA)—were measured using in-house software and compared with the pulmonary function test (PFT) results. Results: The overall accuracy of the combined segmentation method was 97.22% ± 4.44% while the visual accuracy of the models for the segmented diaphragms was 95.28% ± 2.52% (mean ± SD). The quantitative parameters, including SIA, CA, H, XL, YL, ZL, FZL, C, and SA were 0.85 ± 0.05 (mm{sup −1}), 0.01 ± 0.00 (mm{sup −1}), 17.93 ± 10.78 (mm), 129.80 ± 11.66 (mm), 163.19 ± 13.45 (mm), 71

  14. Variation compensation and analysis on diaphragm curvature analysis for emphysema quantification on whole lung CT scans

    Science.gov (United States)

    Keller, Brad M.; Reeves, Anthony P.; Barr, R. Graham; Yankelevitz, David F.; Henschke, Claudia I.

    2010-03-01

    CT scans allow for the quantitative evaluation of the anatomical bases of emphysema. Recently, a non-density based geometric measurement of lung diagphragm curvature has been proposed as a method for the quantification of emphysema from CT. This work analyzes variability of diaphragm curvature and evaluates the effectiveness of a compensation methodology for the reduction of this variability as compared to emphysema index. Using a dataset of 43 scan-pairs with less than a 100 day time-interval between scans, we find that the diaphragm curvature had a trend towards lower overall variability over emphysema index (95% CI:-9.7 to + 14.7 vs. -15.8 to +12.0), and that the variation of both measures was reduced after compensation. We conclude that the variation of the new measure can be considered comparable to the established measure and the compensation can reduce the apparent variation of quantitative measures successfully.

  15. MDCT diagnosis of penetrating diaphragm injury

    Energy Technology Data Exchange (ETDEWEB)

    Bodanapally, Uttam K.; Shanmuganathan, Kathirkamanathan; Mirvis, Stuart E.; Sliker, Clint W.; Fleiter, Thorsten R.; Sarada, Kamal; Miller, Lisa A. [University of Maryland School of Medicine, Department of Diagnostic Radiology, Baltimore, MD (United States); Stein, Deborah M. [University of Maryland, Department of Surgery, Shock Trauma Center, Baltimore, MD (United States); Alexander, Melvin [National Study Center for Trauma and Emergency Medical Systems, Baltimore, MD (United States)

    2009-08-15

    The purpose of the study was to determine the diagnostic sensitivity and specificity of multidetector CT (MDCT) in detection of diaphragmatic injury following penetrating trauma. Chest and abdominal CT examinations performed preoperatively in 136 patients after penetrating trauma to the torso with injury trajectory in close proximity to the diaphragm were reviewed by radiologists unaware of surgical findings. Signs associated with diaphragmatic injuries in penetrating trauma were noted. These signs were correlated with surgical diagnoses, and their sensitivity and specificity in assisting the diagnosis were calculated. CT confirmed diaphragmatic injury in 41 of 47 injuries (sensitivity, 87.2%), and an intact diaphragm in 71 of 98 patients (specificity, 72.4%). The overall accuracy of MDCT was 77%. The most accurate sign helping the diagnosis was contiguous injury on either side of the diaphragm in single-entry penetrating trauma (sensitivity, 88%; specificity, 82%). Thus MDCT has high sensitivity and good specificity in detecting penetrating diaphragmatic injuries. (orig.)

  16. MDCT diagnosis of penetrating diaphragm injury

    International Nuclear Information System (INIS)

    Bodanapally, Uttam K.; Shanmuganathan, Kathirkamanathan; Mirvis, Stuart E.; Sliker, Clint W.; Fleiter, Thorsten R.; Sarada, Kamal; Miller, Lisa A.; Stein, Deborah M.; Alexander, Melvin

    2009-01-01

    The purpose of the study was to determine the diagnostic sensitivity and specificity of multidetector CT (MDCT) in detection of diaphragmatic injury following penetrating trauma. Chest and abdominal CT examinations performed preoperatively in 136 patients after penetrating trauma to the torso with injury trajectory in close proximity to the diaphragm were reviewed by radiologists unaware of surgical findings. Signs associated with diaphragmatic injuries in penetrating trauma were noted. These signs were correlated with surgical diagnoses, and their sensitivity and specificity in assisting the diagnosis were calculated. CT confirmed diaphragmatic injury in 41 of 47 injuries (sensitivity, 87.2%), and an intact diaphragm in 71 of 98 patients (specificity, 72.4%). The overall accuracy of MDCT was 77%. The most accurate sign helping the diagnosis was contiguous injury on either side of the diaphragm in single-entry penetrating trauma (sensitivity, 88%; specificity, 82%). Thus MDCT has high sensitivity and good specificity in detecting penetrating diaphragmatic injuries. (orig.)

  17. Assessing breathing motion by shape matching of lung and diaphragm surfaces

    Science.gov (United States)

    Urschler, Martin; Bischof, Horst

    2005-04-01

    Studying complex thorax breating motion is an important research topic for accurate fusion of functional and anatomical data, radiotherapy planning or reduction of breathing motion artifacts. We investigate segmented CT lung, airway and diaphragm surfaces at several different breathing states between Functional Residual and Total Lung Capacity. In general, it is hard to robustly derive corresponding shape features like curvature maxima from lung and diaphragm surfaces since diaphragm and rib cage muscles tend to deform the elastic lung tissue such that e.g. ridges might disappear. A novel registration method based on the shape context approach for shape matching is presented where we extend shape context to 3D surfaces. The shape context approach was reported as a promising method for matching 2D shapes without relying on extracted shape features. We use the point correspondences for a non-rigid thin-plate-spline registration to get deformation fields that describe the movement of lung and diaphragm. Our validation consists of experiments on phantom and real sheep thorax data sets. Phantom experiments make use of shapes that are manipulated with known transformations that simulate breathing behaviour. Real thorax data experiments use a data set showing lungs and diaphragm at 5 distinct breathing states, where we compare subsets of the data sets and qualitatively and quantitatively asses the registration performance by using manually identified corresponding landmarks.

  18. The use of thin-section high-resolution CT in pediatric pulmonary disease

    International Nuclear Information System (INIS)

    Hay, T.C.; Horgan, J.G.; Rumack, C.M.

    1989-01-01

    High-resolution thin-section CT of the chest was used successfully to characterize the extent of pulmonary disease. This paper reports on a study in which ten children with chronic lung disorders (including cystic fibrosis, reactive airway disease, and idiopathic disease) were evaluated to test the accuracy of the posteroanterior and lateral chest CT, with both thick (1 cm) and thin (1-3 mm) sections. Unsuspected bronchiectasis was established n two patients with reactive airway disease, and the extent of bronchiectasis in other patients was best defined on thin-section CT. Technique was crucial for an accurate study, and magnification views of each lung were useful. Thin-section CT of the chest was helpful in defining and localizing the extent of these pulmonary disorders

  19. 1975 Memorial Award Paper. Image generation and display techniques for CT scan data. Thin transverse and reconstructed coronal and sagittal planes.

    Science.gov (United States)

    Glenn, W V; Johnston, R J; Morton, P E; Dwyer, S J

    1975-01-01

    The various limitations to computerized axial tomographic (CT) interpretation are due in part to the 8-13 mm standard tissue plane thickness and in part to the absence of alternative planes of view, such as coronal or sagittal images. This paper describes a method for gathering multiple overlapped 8 mm transverse sections, subjecting these data to a deconvolution process, and then displaying thin (1 mm) transverse as well as reconstructed coronal and sagittal CT images. Verification of the deconvolution technique with phantom experiments is described. Application of the phantom results to human post mortem CT scan data illustrates this method's faithful reconstruction of coronal and sagittal tissue densities when correlated with actual specimen photographs of a sectioned brain. A special CT procedure, limited basal overlap scanning, is proposed for use on current first generation CT scanners without hardware modification.

  20. Squalene aspiration pneumonia : thin-section CT and histopathologic findings

    International Nuclear Information System (INIS)

    Lee, Jin Seong; Gong, Gyung Yub; Lim, Tae Hwan

    1998-01-01

    The purpose of this study was to describe the thin-section computed tomography (CT) findings and histopathologic findings of squalene aspiration pneumonia. Thin-section CT scans were obtained from nine patients with proven exogenous lipoid pneumonia resulting from aspiration of squalene (derived from shark liver oil). The condition was diagnosed by biopsy (n=3), bronchoalveolar lavage(n=4), or sputum cytology and clinical history (n=2) of squalene use was confirmed in all patients. Specimens of transbronchial lung biopsy were also reviewed and compared with thin-section CT findings. On the basis of these results, we concluded that squalene aspiration pneumonia can be reliably diagnosed by thin-section CT findings particularly when the appropriate history is known. (author). 19 refs., 3 figs

  1. Measurement of thermal expansion coefficient of graphene diaphragm using optical fiber Fabry–Perot interference

    International Nuclear Information System (INIS)

    Li, Cheng; Liu, Qianwen; Peng, Xiaobin; Fan, Shangchun

    2016-01-01

    Application of the Fabry–Perot (FP) interference method for determining the coefficient of thermal expansion (CTE) of a graphene diaphragm is investigated in this paper. A miniature extrinsic FP interferometric (EFPI) sensor was fabricated by using an approximate 8-layer graphene diaphragm. The extremely thin diaphragm was transferred onto the endface of a ferrule with an inner diameter of 125 μ m, and van der Waals interactions between the graphene diaphragm and its substrate created a low finesse FP interferometer with a cavity length of 36.13 μ m. Double reference FP cavities using two cleaved optical fibers as reflectors were also constructed to differentially cancel the thermal expansion effects of the trapped gas and adhesive material. A temperature test demonstrated an approximate cavity length change of 166.1 nm °C −1 caused by film thermal expansion in the range of 20–60 °C. Then along with the established thermal deformation model of the suspended circular diaphragm, the calculated CTE ranging from  −9.98  ×  10 −6 K −1 to  −2.09  ×  10 −6 K −1 conformed well to the previously measured results. The proposed method would be applicable in other types of elastic materials as the sensitive diaphragm of an EFPI sensor over a wide temperature range. (paper)

  2. Numerical investigation on vibration characteristics of a micro-speaker diaphragm considering thermoforming effects

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyeong Min; Park, Ke Un [Seoul National University of Science and Technology, Seoul (Korea, Republic of)

    2013-10-15

    Micro-speaker diaphragms play an important role in generating desired sound responses, and are designed to have thin membrane shapes for flexibility in the axial direction. The micro-speaker diaphragms are formed from thin polymer film through the thermoforming process, in which local thickness reductions occur due to strain localization. This thickness reduction results in a change in vibration characteristics of the diaphragm and different sound responses from that of the original design. In this study, the effect of this thickness change in the diaphragm on its vibration characteristics is numerically investigated by coupling thermoforming simulation, structural analysis and modal analysis. Thus, the thickness change in the diaphragm is calculated from the thermoforming simulation, and reflected in the further structural and modal analyses in order to estimate the relevant stiffness and vibration modes. Comparing these simulation results with those from a diaphragm with the uniform thickness, it is found that a local thickness reduction results in the stiffness reduction and the relevant change in the natural frequencies and the corresponding vibration modes.

  3. Numerical investigation on vibration characteristics of a micro-speaker diaphragm considering thermoforming effects

    International Nuclear Information System (INIS)

    Kim, Kyeong Min; Park, Ke Un

    2013-01-01

    Micro-speaker diaphragms play an important role in generating desired sound responses, and are designed to have thin membrane shapes for flexibility in the axial direction. The micro-speaker diaphragms are formed from thin polymer film through the thermoforming process, in which local thickness reductions occur due to strain localization. This thickness reduction results in a change in vibration characteristics of the diaphragm and different sound responses from that of the original design. In this study, the effect of this thickness change in the diaphragm on its vibration characteristics is numerically investigated by coupling thermoforming simulation, structural analysis and modal analysis. Thus, the thickness change in the diaphragm is calculated from the thermoforming simulation, and reflected in the further structural and modal analyses in order to estimate the relevant stiffness and vibration modes. Comparing these simulation results with those from a diaphragm with the uniform thickness, it is found that a local thickness reduction results in the stiffness reduction and the relevant change in the natural frequencies and the corresponding vibration modes.

  4. Design and analysis of diaphragms in dynamic microphones

    Directory of Open Access Journals (Sweden)

    Zi-Gui Huang

    2015-07-01

    Full Text Available Most contemporary high-end microphones are dynamic microphones, adopting the most basic electromagnetic transduction principles. This study investigated the diaphragm structures of dynamic microphones. The diaphragms were composed of polyimide material, and the boundary settings required for actual operation were provided using finite element model analysis software. The characteristic frequencies caused by grooving variations on the three-dimensional diaphragm were analyzed for the various groove shapes and number. The groove angles and width variations were examined based on the optimal groove shape selected in the aforementioned analysis, and the effects of these shapes were determined based on the analytical results. Acoustic waves cause thin films to vibrate, forming the working principle behind dynamic microphones. The thin film drives a coil to vibrate in a magnetic field and cuts the line of magnetic force, subsequently producing a voltage on both ends of the coil. This audio-frequency-inducted voltage represents an acoustic wave message. The finite element model analysis software was used to conduct electromagnetic induction simulations; the sound source was fed to the diaphragm to drive the coil. The coil vibrations caused the line of magnetic force to be cut, and the final voltages produced were examined and compared.

  5. Thin-section CT of Cushing's disease

    International Nuclear Information System (INIS)

    Takahashi, Tatsuo; Kuwayama, Akio; Katoh, Tetsuo; Ichihara, Kaoru; Kageyama, Naoki; Nakamura, Koji.

    1983-01-01

    Using 1.5 mm contiguous sections with a GE CT/T 8800 scanner, we investigated the sellar regions of 22 cases of Cushing's diseases which had been diagnosed endocrinologically. Each sellar turcica was normal in size, and in only 5 cases were there significant findings on 2 mm-thick sellar-floor polytomography. Nine tumors appeared as regions of a hypodense area, and three tumors were diagnosed by indirect signs, for example, stalk deviation and diaphragmatic plane asymmetry. The other 10 cases, especially those previously operated on or irradiated, were diagnosed as falsely positive or negative. Because it is best of the microadenomas appear hypodense within the strongly contrast-enhanced anterior pituitary glands, it is better for scans to be obtained immediately after rapid intravenous contrast infusion. Hypodense areas of microadenomas are best demonstrated on direct coronal scans or reversed scans of 1.5 mm-thickness thin-slice sections. By these methods, microadenomas, if they are over 5-6 mm in diameter, can appear as hypodense. Sellar floor findings by means of thin-section CT were more sensitive than those of polytomography and had more advantages in local diagnosis. If the tumor were over 4 mm in diameter, local changes in the sellar floor could be demonstrated by thin-section CT, but by polytomography no changes in the sellar floor could be demonstrated until the tumor size reached 6 mm. (author)

  6. The influence of tensile forces on the deflection of circular diaphragms in pressure sensors

    NARCIS (Netherlands)

    Voorthuyzen, J.A.; Bergveld, Piet

    1984-01-01

    It is known that the deflection of a diaphragm is determined by two mechanisms, bending moments or bending stress and tensile forces or membrane stress. Usually the influence of tensile forces is not taken into account when calculating the mechanical properties of thin diaphragms. Hence the

  7. Acute eosinophilic pneumonia: Thin-section CT findings in 29 patients

    International Nuclear Information System (INIS)

    Daimon, Tadahisa; Johkoh, Takeshi; Sumikawa, Hiromitsu; Honda, Osamu; Fujimoto, Kiminori; Koga, Takeharu; Arakawa, Hiroaki; Yanagawa, Masahiro; Inoue, Atsuo; Mihara, Naoki; Tomiyama, Noriyuki

    2008-01-01

    Purpose: To determine thin-section computed tomography (CT) characteristics of acute eosinophilic pneumonia (AEP). Materials and methods: Thin-section CT scans of 29 patients (14 males, 15 females; mean age, 26 ± 15 years; age range, 15-72 years) with AEP were included this retrospective study. The clinical diagnosis of AEP was established by Allen's criteria. Each thin-section CT was reviewed by two observers. Results: Bilateral areas with ground-glass attenuation were observed on thin-section CT in all patients. Areas of air-space consolidation were present in 16 (55%) of 29 patients. Poorly defined centrilobular nodules were present in 9 patients (31%). Interlobular septal thickening was present in 26 patients (90%). Thickening of bronchovascular bundles was present in 19 patients (66%). Pleural effusions were present in 23 patients (79%) (bilateral = 22, right side = 1, left side = 0). The predominant overall anatomic distribution was central in only 2 (7%) of 29 patients, peripheral in 9 patients (31%), and random in 18 patients (62%). The overall zonal predominance was upper in 4 patients (14%), lower in 8 patients (28%), and random in 17 patients (58%). Conclusion: CT findings in AEP patients consisted mainly of bilateral areas of ground-glass attenuation, interlobular septal thickening, thickening of bronchovascular bundles, and the presence of a pleural effusion without cardiomegaly. The most common overall anatomic distribution and zonal predominance of the abnormal CT findings were random

  8. Acute eosinophilic pneumonia: Thin-section CT findings in 29 patients

    Energy Technology Data Exchange (ETDEWEB)

    Daimon, Tadahisa [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan); Department of Medicine, Division of Pulmonary Medicine, Jichi Medical University, Yakushiji 3311-1, Shimotsuke, Tochigi 329-0498 (Japan)], E-mail: t-daimon@radiol.med.osaka-u.ac.jp; Johkoh, Takeshi [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: johkoh@sahs.med.osaka-u.ac.jp; Sumikawa, Hiromitsu [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: h-sumikawa@radiol.med.osaka-u.ac.jp; Honda, Osamu [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: ohonda@radiol.med.osaka-u.ac.jp; Fujimoto, Kiminori [Department of Radiology, Kurume University School of Medicine, 67 Asahi-machi, Kurume 830-0011 (Japan)], E-mail: kimichan@med.kurume-u.ac.jp; Koga, Takeharu [Department of Medicine, Division of Respirology and Neurology, Kurume University School of Medicine, 67 Asahi-machi, Kurume 830-0011 (Japan)], E-mail: kogat@med.kurume-u.ac.jp; Arakawa, Hiroaki [Department of Radiology, Dokkyo University School of Medicine, 880 Kita-Kobayashi, Mibu, Tochigi 321-0293 (Japan)], E-mail: arakawa@dokkyomed.ac.jp; Yanagawa, Masahiro [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: m-yanagawa@radiol.med.osaka-u.ac.jp; Inoue, Atsuo [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: ainoue@radiol.med.osaka-u.ac.jp; Mihara, Naoki [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: nmihara@radiol.med.osaka-u.ac.jp; Tomiyama, Noriyuki [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: tomiyama@radiol.med.osaka-u.ac.jp (and others)

    2008-03-15

    Purpose: To determine thin-section computed tomography (CT) characteristics of acute eosinophilic pneumonia (AEP). Materials and methods: Thin-section CT scans of 29 patients (14 males, 15 females; mean age, 26 {+-} 15 years; age range, 15-72 years) with AEP were included this retrospective study. The clinical diagnosis of AEP was established by Allen's criteria. Each thin-section CT was reviewed by two observers. Results: Bilateral areas with ground-glass attenuation were observed on thin-section CT in all patients. Areas of air-space consolidation were present in 16 (55%) of 29 patients. Poorly defined centrilobular nodules were present in 9 patients (31%). Interlobular septal thickening was present in 26 patients (90%). Thickening of bronchovascular bundles was present in 19 patients (66%). Pleural effusions were present in 23 patients (79%) (bilateral = 22, right side = 1, left side = 0). The predominant overall anatomic distribution was central in only 2 (7%) of 29 patients, peripheral in 9 patients (31%), and random in 18 patients (62%). The overall zonal predominance was upper in 4 patients (14%), lower in 8 patients (28%), and random in 17 patients (58%). Conclusion: CT findings in AEP patients consisted mainly of bilateral areas of ground-glass attenuation, interlobular septal thickening, thickening of bronchovascular bundles, and the presence of a pleural effusion without cardiomegaly. The most common overall anatomic distribution and zonal predominance of the abnormal CT findings were random.

  9. Diaphragm flange and method for lowering particle beam impedance at connected beam tubes of a particle accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Biallas, George Herman

    2017-07-04

    A diaphragm flange for connecting the tubes in a particle accelerator while minimizing beamline impedance. The diaphragm flange includes an outer flange and a thin diaphragm integral with the outer flange. Bolt holes in the outer flange provide a means for bolting the diaphragm flange to an adjacent flange or beam tube having a mating bolt-hole pattern. The diaphragm flange includes a first surface for connection to the tube of a particle accelerator beamline and a second surface for connection to a CF flange. The second surface includes a recessed surface therein and a knife-edge on the recessed surface. The diaphragm includes a thickness that enables flexing of the integral diaphragm during assembly of beamline components. The knife-edge enables compression of a soft metal gasket to provide a leak-tight seal.

  10. Artificial intelligence aiding the thin-section CT diagnosis of diffuse pulmonary diseases

    International Nuclear Information System (INIS)

    Han, Dae Hee; Koh, Young Hwan; Seong, Chang Kyu; Kim, Ji Hoon; Choi, Young Ho; Kim, Jong Hyo; Chae, Young Moon; Lee, Yun Hee; Han, Heon

    2006-01-01

    We wanted to develop and test an artificial intelligence (AI) to assist physicians in making the thin-section CT diagnosis of diffuse pulmonary diseases. The AI was composed of knowledge bases (KB) of 12 diffuse pulmonary diseases and an inference engine (IE). The KB of a disease included both the inclusion criteria (IC) and the exclusion criteria (EC), which were the clinical or thin-section CT findings that were known to be present or absent in that particular disease, respectively. From imputing the clinical or thin-section CT findings by the operator who was reading the thin-section CT, AI instantly executed the following two steps. First, the IE eliminated all diseases from the list which the EC had for those particular findings. Next, from a list or remaining diseases, the AI selected those diseases having those findings in its IC to formulate the 1st-step differential diagnosis (DD1). For the differential diagnosis in the next step, the reader could choose one more clinical or thin-section CT finding from the new list: [(all the findings in the IC or EC of DD1)-(the findings in the IC common to all the DD1s)]. The reader could proceed even further if needed. The system was tested on 10 radiology residents who solved 24 problems (two problems for each of 12 diffuse pulmonary diseases) without and then with the aid of the AI. The scores were compared using the Wilcoxon signed rank test. An AI was made; it was composed of 280 rules (214 IC and 66 EC) and there interfaces (two for program management and another for problem solving). Contestants scored higher (ρ = 0.0078) using the AI (167 vs. 110 respectively), and they responded that they felt that the program was helpful in making decisions. AI appeared to be helpful in making thin-section CT diagnosis

  11. Artificial intelligence aiding the thin-section CT diagnosis of diffuse pulmonary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Han, Dae Hee; Koh, Young Hwan; Seong, Chang Kyu; Kim, Ji Hoon; Choi, Young Ho [Boramae Munincipal Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Jong Hyo [Seoul National University College of Medicine, Seoul (Korea, Republic of); Chae, Young Moon [Yonsei University Graduate School of Public Heath, Seoul (Korea, Republic of); Lee, Yun Hee [The Graduate School of Imformation, Yonsei, Seoul (Korea, Republic of); Han, Heon [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2006-06-15

    We wanted to develop and test an artificial intelligence (AI) to assist physicians in making the thin-section CT diagnosis of diffuse pulmonary diseases. The AI was composed of knowledge bases (KB) of 12 diffuse pulmonary diseases and an inference engine (IE). The KB of a disease included both the inclusion criteria (IC) and the exclusion criteria (EC), which were the clinical or thin-section CT findings that were known to be present or absent in that particular disease, respectively. From imputing the clinical or thin-section CT findings by the operator who was reading the thin-section CT, AI instantly executed the following two steps. First, the IE eliminated all diseases from the list which the EC had for those particular findings. Next, from a list or remaining diseases, the AI selected those diseases having those findings in its IC to formulate the 1st-step differential diagnosis (DD1). For the differential diagnosis in the next step, the reader could choose one more clinical or thin-section CT finding from the new list: [(all the findings in the IC or EC of DD1)-(the findings in the IC common to all the DD1s)]. The reader could proceed even further if needed. The system was tested on 10 radiology residents who solved 24 problems (two problems for each of 12 diffuse pulmonary diseases) without and then with the aid of the AI. The scores were compared using the Wilcoxon signed rank test. An AI was made; it was composed of 280 rules (214 IC and 66 EC) and there interfaces (two for program management and another for problem solving). Contestants scored higher ({rho} = 0.0078) using the AI (167 vs. 110 respectively), and they responded that they felt that the program was helpful in making decisions. AI appeared to be helpful in making thin-section CT diagnosis.

  12. The Stress and Stiffness Analysis of Diaphragm

    Directory of Open Access Journals (Sweden)

    Qu Dongyue

    2017-01-01

    Full Text Available Diaphragm coupling with its simple structure, small size, high reliability, which can compensate for its input and output displacement deviation by its elastic deformation, is widely used in aerospace, marine, and chemical etc. This paper uses the ANSYS software and its APDL language to analysis the stress distribution when the diaphragm under the load of torque, axial deviation, centrifugal force, angular deviation and multiple loads. We find that the value of maximum stress usually appears in the outer or inner transition region and the axial deviation has a greater influence to the distribution of the stress. Based on above, we got three kinds of stiffness for axial, angular and torque, which the stiffness of diaphragm is nearly invariable. The results can be regard as an important reference for design and optimization of diaphragm coupling.

  13. Design of pressure-sensing diaphragm for MEMS capacitance diaphragm gauge considering size effect

    Science.gov (United States)

    Li, Gang; Li, Detian; Cheng, Yongjun; Sun, Wenjun; Han, Xiaodong; Wang, Chengxiang

    2018-03-01

    MEMS capacitance diaphragm gauge with a full range of (1˜1000) Pa is considered for its wide application prospect. The design of pressure-sensing diaphragm is the key to achieve balanced performance for this kind of gauges. The optimization process of the pressure-sensing diaphragm with island design of a capacitance diaphragm gauge based on MEMS technique has been reported in this work. For micro-components in micro scale range, mechanical properties are very different from that in the macro scale range, so the size effect should not be ignored. The modified strain gradient elasticity theory considering size effect has been applied to determine the bending rigidity of the pressure-sensing diaphragm, which is then used in the numerical model to calculate the deflection-pressure relation of the diaphragm. According to the deflection curves, capacitance variation can be determined by integrating over the radius of the diaphragm. At last, the design of the diaphragm has been optimized based on three parameters: sensitivity, linearity and ground capacitance. With this design, a full range of (1˜1000) Pa can be achieved, meanwhile, balanced sensitivity, resolution and linearity can be kept.

  14. Experimental investigation of solar powered diaphragm and helical pumps

    Science.gov (United States)

    For several years, many types of solar powered water pumping systems were evaluated, and in this paper, diaphragm and helical solar photovoltaic (PV) powered water pumping systems are discussed. Data were collected on diaphragm and helical pumps which were powered by different solar PV arrays at mul...

  15. Parametric study of roof diaphragm stiffness requirements

    International Nuclear Information System (INIS)

    Jones, W.D.; Tenbus, M.A.

    1991-01-01

    A common assumption made in performing a dynamic seismic analysis for a building is that the roof/floor system is open-quotes rigidclose quotes. This assumption would appear to be reasonable for many of the structures found in nuclear power plants, since many of these structures are constructed of heavily reinforced concrete having floor/roof slabs at least two feet in thickness, and meet the code requirements for structural detailing for seismic design. The roofs of many Department of Energy (DOE) buildings at the Oak Ridge Y-12 Plant in Oak Ridge, Tennessee, have roofs constructed of either metal, precast concrete or gypsum plank deck overlaid with rigid insulation, tar and gravel. In performing natural phenomena hazard assessments for one such facility, it was assumed that the existing roof performed first as a flexible diaphragm (zero stiffness) and then, rigid (infinitely stiff). For the flexible diaphragm model it was determined that the building began to experience significant damage around 0.09 g's. For the rigid diaphragm model it was determined that no significant damage was observed below 0.20 g's. A Conceptual Design Report has been prepared for upgrading/replacing the roof of this building. The question that needed to be answered here was, open-quotes How stiff should the new roof diaphragm be in order to satisfy the rigid diaphragm assumption and, yet, be cost effective?close quotes. This paper presents a parametric study of a very simple structural system to show that the design of roof diaphragms needs to consider both strength and stiffness (frequency) requirements. This paper shows how the stiffness of a roof system affects the seismically induced loads in the lateral, vertical load resisting elements of a building and provides guidance in determining how open-quotes rigidclose quotes a roof system should be in order to accomplish a cost effective design

  16. Analytical model for an electrostatically actuated miniature diaphragm compressor

    International Nuclear Information System (INIS)

    Sathe, Abhijit A; Groll, Eckhard A; Garimella, Suresh V

    2008-01-01

    This paper presents a new analytical approach for quasi-static modeling of an electrostatically actuated diaphragm compressor that could be employed in a miniature scale refrigeration system. The compressor consists of a flexible circular diaphragm clamped at its circumference. A conformal chamber encloses the diaphragm completely. The membrane and the chamber surfaces are coated with metallic electrodes. A potential difference applied between the diaphragm and the chamber pulls the diaphragm toward the chamber surface progressively from the outer circumference toward the center. This zipping actuation reduces the volume available to the refrigerant gas, thereby increasing its pressure. A segmentation technique is proposed for analysis of the compressor by which the domain is divided into multiple segments for each of which the forces acting on the diaphragm are estimated. The pull-down voltage to completely zip each individual segment is thus obtained. The required voltage for obtaining a specific pressure rise in the chamber can thus be determined. Predictions from the model compare well with other simulation results from the literature, as well as to experimental measurements of the diaphragm displacement and chamber pressure rise in a custom-built setup

  17. The value of spiral CT thin imaging reconstruction in the diagnosis of obstructive jaundice

    International Nuclear Information System (INIS)

    Huang Zhi; Liu Zhang; Yang Chaoxiang; Lin Chengye; Zhang Li; Li Yuxiang; Ma Yunyan; Xiao Haisong; Lu Zhifeng; Wang Bo; Zhou Yunhong

    2009-01-01

    Objective: To approach the value of spiral CT thin imaging reconstruction in the diagnosis of obstructive jaundice in order to improve the correctness of the diagnosis. Methods: Analysis the cases' clinical manifestation and the CT images, who were diagnosed as obstructive jaundice by operation. All of cases had high-resolution computed tomograyhy scan. The thickness and the interval is 5mm, reconstructed the thickness and the interval to 1 mm and 1.5 mm, then send the images to the workstation and MRR were processed. Analysis the date with the pathology. Results: Spiral CT thin imaging reconstruction have 98% and 93% in the accuracy of location and characterization in the obstruction. Conclusion: The spiral CT thin imaging reconstruction is a good method to improve the accuracy of location and characterization in the obstructive jaundice. (authors)

  18. Analytical investigation of bidirectional ductile diaphragms in multi-span bridges

    Science.gov (United States)

    Wei, Xiaone; Bruneau, Michel

    2018-04-01

    In the AASHTO Guide Specifications for Seismic Bridge Design Provisions, ductile diaphragms are identified as Permissible Earthquake-Resisting Elements (EREs), designed to help resist seismic loads applied in the transverse direction of bridges. When adding longitudinal ductile diaphragms, a bidirectional ductile diaphragm system is created that can address seismic excitations acting along both the bridge's longitudinal and transverse axes. This paper investigates bidirectional ductile diaphragms with Buckling Restrained Braces (BRBs) in straight multi-span bridge with simply supported floating spans. The flexibility of the substructures in the transverse and longitudinal direction of the bridge is considered. Design procedures for the bidirectional ductile diaphragms are first proposed. An analytical model of the example bridge with bidirectional ductile diaphragms, designed based on the proposed methodology, is then built in SAP2000. Pushover and nonlinear time history analyses are performed on the bridge model, and corresponding results are presented. The effect of changing the longitudinal stiffness of the bidirectional ductile diaphragms in the end spans connecting to the abutment is also investigated, in order to better understand the impact on the bridge's dynamic performance.

  19. Mathematical Modeling of Diaphragm Pneumatic Motors

    Directory of Open Access Journals (Sweden)

    Fojtášek Kamil

    2014-03-01

    Full Text Available Pneumatic diaphragm motors belong to the group of motors with elastic working parts. This part is usually made of rubber with a textile insert and it is deformed under the pressure of a compressed air or from the external mass load. This is resulting in a final working effect. In this type of motors are in contact two different elastic environments – the compressed air and the esaltic part. These motors are mainly the low-stroke and working with relatively large forces. This paper presents mathematical modeling static properties of diaphragm motors.

  20. Thin-slice high-resolution CT study of pulmonary asbestosis and idiopathic interstitial pneumonia

    International Nuclear Information System (INIS)

    Hatakeyama, Masayuki; Maeda, Munehiro; Ohmura, Takuya

    1987-01-01

    Thin-slice high-resolution CT findings were compared between 36 patients with pulmonary asbestos exposure (AS) and 33 patients with idiopathic interstitial pneumonia (IIP). The CT scans of these patients were classified into 5 types (0-IV) by the subpleural curvilinear shadow (SCLS) and honey-comb shadow (HS). SCLS was detected in 22 (62 %) patients with AS and 7 (21 %) with IIP. HS was detected in 14 (39 %) patients with AS and 33 (100 %) with IIP. In both the diseases, SCLS was distributed mainly in the lower lobe in CT types I and II, and in mildly fibrotic segments in types III and IV. In CT types II, III and IV, SCLS was always communicated with HS. Thin-slice high-resolution CT is considered very helpful in diagnosis and staging of not only AS and IIP but also pulmonary fibrosis. (author)

  1. Pulmonary candidiasis after hematopoietic stem cell transplantation: thin-section CT findings.

    Science.gov (United States)

    Franquet, Tomás; Müller, Nestor L; Lee, Kyung S; Oikonomou, Anastasia; Flint, Julia D

    2005-07-01

    To retrospectively evaluate thin-section computed tomographic (CT) findings in hematopoietic stem cell transplant (ie, bone marrow transplant) patients with histopathologically proved pulmonary candidiasis. Ethical approval was obtained from the institutional review board of each of the three institutions; informed consent was not required. The study included 17 hematopoietic stem cell transplant recipients with proved pulmonary candidiasis. Histopathologic specimens were acquired at transbronchial biopsy (n = 8), open lung biopsy (n = 6), and autopsy (n = 3). The patients included seven men and 10 women (age range, 20-62 years; mean age, 37 years). The thin-section CT scans were retrospectively reviewed by two thoracic radiologists for the presence, appearance, and distribution of parenchymal abnormalities. Multiple nodules were present in 15 (88%) patients, including centrilobular nodules and tree-in-bud pattern in seven (41%) patients. Nodules were bilateral in 12 patients and unilateral in three. An associated halo of ground-glass opacity was identified in five (33%) patients. Nodules were the only CT finding in five patients (29%). Areas of air-space consolidation were identified in 11 (65%) patients. Areas of ground-glass opacity were seen in six (35%) of 17 patients and were always associated with other abnormalities. Other less common CT findings included pleural effusion (n = 3), thickening of the bronchial walls (n = 2), and cavitation (n = 1). The most common thin-section CT findings of pulmonary candidiasis in hematopoietic stem cell transplant patients are multiple bilateral nodular opacities often associated with areas of consolidation. Copyright RSNA, 2005

  2. Radial Field Piezoelectric Diaphragms

    Science.gov (United States)

    Bryant, R. G.; Effinger, R. T., IV; Copeland, B. M., Jr.

    2002-01-01

    A series of active piezoelectric diaphragms were fabricated and patterned with several geometrically defined Inter-Circulating Electrodes "ICE" and Interdigitated Ring Electrodes "ICE". When a voltage potential is applied to the electrodes, the result is a radially distributed electric field that mechanically strains the piezoceramic along the Z-axis (perpendicular to the applied electric field). Unlike other piezoelectric bender actuators, these Radial Field Diaphragms (RFDs) strain concentrically yet afford high displacements (several times that of the equivalent Unimorph) while maintaining a constant circumference. One of the more intriguing aspects is that the radial strain field reverses itself along the radius of the RFD while the tangential strain remains relatively constant. The result is a Z-deflection that has a conical profile. This paper covers the fabrication and characterization of the 5 cm. (2 in.) diaphragms as a function of poling field strength, ceramic thickness, electrode type and line spacing, as well as the surface topography, the resulting strain field and displacement as a function of applied voltage at low frequencies. The unique features of these RFDs include the ability to be clamped about their perimeter with little or no change in displacement, the environmentally insulated packaging, and a highly repeatable fabrication process that uses commodity materials.

  3. Design of Diaphragm Based MEMS Pressure Sensor with Sensitivity Analysis for Environmental Applications

    Directory of Open Access Journals (Sweden)

    A. Nallathambi

    2015-05-01

    Full Text Available In this paper Micro-electromechanical System (MEMS diaphragm based pressure sensor for environmental applications is discussed. The main focus of this paper is to design, simulate and analyze the sensitivity of MEMS based diaphragm using different structures to measure the low and high pressure values. The simulation is done through the finite element tool and specifications related the maximum convinced stress; deflection and sensitivity of the diaphragms have been analyzed using the software INTELLISUITE 8.7v. The change in pressure is to bending of the diaphragm that modifies the measured displacement between the substrate and the diaphragm. This change in displacement gives the measure of the pressure in that environment. The design of these studies can be used to improve the sensitivity of these devices. Here the diaphragm based pressure sensor produced better displacement, sensitivity and stress output responses are obtained from the square diaphragm. The pressure range from 0.6 MPa to 25 MPa and its maximum displacement is accordingly 59 mm over a pressure range of 0 to 2 MPa. Its sensitivity is therefore 2.35 [10E-12/Pa].

  4. Non-contrast thin-section helical CT of urinary tract calculi in children

    International Nuclear Information System (INIS)

    Strouse, Peter J.; Bates, Gregory D.; Bloom, David A.; Goodsitt, Mitchell M.

    2002-01-01

    Background: Non-contrast thin-section helical CT has gained acceptance for the diagnosis of urinary tract calculi in adults, but experience with the technique in children is limited. Purpose: To evaluate the utility of non-contrast thin section helical CT for the diagnosis of urinary tract calculi in children. Materials and methods: Radiology databases at three pediatric institutions were searched to identify all pediatric patients evaluated by ''renal stone'' protocol CT scans (no oral or intravenous contrast, scans covering the entire urinary tract obtained in helical mode with narrow collimation (< 5 mm)). CT scans were reviewed for the primary finding of urinary tract calculi, for secondary signs of acute urinary tract obstruction and for evidence of alternative diagnoses. Medical records were reviewed to determine clinical presentation and to confirm the eventual diagnosis. Results: One hundred thirty-seven scans of 113 children (mean age: 11.2 years) were studied. Thirty-eight of 94 examinations (40%) performed on 82 children for acute pain and/or hematuria showed ureteral calculi. Alternative diagnoses were suggested by CT on 16 scans (17%). Twenty-eight scans were performed on 10 asymptomatic children with known calculus disease confirming renal stone burden on 21 scans (75%) and persistent ureteral calculi on 6 scans (21%). Upper tract calculi were demonstrated on 10 of 15 scans (67%) performed to evaluate for calculi in patients with known non-calculus genitourinary tract abnormalities. Conclusions: Non-contrast thin section helical CT is a useful method to diagnose urinary tract calculi in children. Radiation dose in this retrospective study may exceed the lowest possible radiation dose for diagnostic accuracy. Further research is needed to optimize CT imaging parameters, while maintaining diagnostic accuracy and minimizing radiation dose. (orig.)

  5. Hematogenous candida pneumonia in major burn patients: plain chest radiograph and thin-section CT findings

    International Nuclear Information System (INIS)

    Kim, Hyo Heon; Lee, Eil Seong; Shim, Ya Seong; Kim, Ji Hun; Suh, Hong Kil; Cho, Sin Young; Kim, Dae Sun; Lee, Kil Woo; Kang, Ik Won

    1995-01-01

    To describe plain radiographic and thin-section CT findings of hematogenous candida pneumonia in major burn patients. We reviewed nine cases of hematogenous candida pneumonia in major burn patients who had positive blood culture for candida and findings of pneumonia on plain chest radiograph. On five of nine cases, thin-section CT was done. We evaluated retrospectively nine cases for onset, the pattern, distribution, and size of lesions on plain chest radiograph and thin-section CT. On plain chest radiograph, randomly distributed 2-10 mm nodules were seen in six cases(66%) and randomly distributed 10-15 mm consolidations in remaining three cases(33%). Lesion occurred in 11th to 75th post-burn day(average, 34th post-burn day). Other findings were cardiomegaly in three cases, atelectasis in three cases, and pulmonary edema in one case. Thin-section CT showed variable shaped subpleural nodules in all five cases. The size of nodules were 1-5 mm in two cases(40%) and 5-10 mm(60%) in three cases. Feeding vessel signs were seen in two cases. Other findings were atelectasis in three cases, cardiomegaly in three cases, ground-glass opacity and interlobular septal thickenings by pulmonary edema in two cases. Plain chest radiographic findings of hematogenous candida pneumonia in major burn patients are randomly distributed nodules or consolidations of variable size. Thin-section CT findings are variable shaped subpleural nodules less than 1 cm

  6. PZT Thin-Film Micro Probe Device with Dual Top Electrodes

    Science.gov (United States)

    Luo, Chuan

    Lead zirconate titanate (PZT) thin-film actuators have been studied intensively for years because of their potential applications in many fields. In this dissertation, a PZT thin-film micro probe device is designed, fabricated, studied, and proven to be acceptable as an intracochlear acoustic actuator. The micro probe device takes the form of a cantilever with a PZT thin-film diaphragm at the tip of the probe. The tip portion of the probe will be implanted in cochlea later in animal tests to prove its feasibility in hearing rehabilitation. The contribution of the dissertation is three-fold. First, a dual top electrodes design, consisting of a center electrode and an outer electrode, is developed to improve actuation displacement of the PZT thin-film diaphragm. The improvement by the dual top electrodes design is studied via a finite element model. When the dimensions of the dual electrodes are optimized, the displacement of the PZT thin-film diaphragm increases about 30%. A PZT thin-film diaphragm with dual top electrodes is fabricated to prove the concept, and experimental results confirm the predictions from the finite element analyses. Moreover, the dual electrode design can accommodate presence of significant residual stresses in the PZT thin-film diaphragm by changing the phase difference between the two electrodes. Second, a PZT thin-film micro probe device is fabricated and tested. The fabrication process consists of PZT thin-film deposition and deep reactive ion etching (DRIE). The uniqueness of the fabrication process is an automatic dicing mechanism that allows a large number of probes to be released easily from the wafer. Moreover, the fabrication is very efficient, because the DRIE process will form the PZT thin-film diaphragm and the special dicing mechanism simultaneously. After the probes are fabricated, they are tested with various possible implantation depths (i.e., boundary conditions). Experimental results show that future implantation depths

  7. Diaphragm Dysfunction in Critical Illness.

    Science.gov (United States)

    Supinski, Gerald S; Morris, Peter E; Dhar, Sanjay; Callahan, Leigh Ann

    2018-04-01

    The diaphragm is the major muscle of inspiration, and its function is critical for optimal respiration. Diaphragmatic failure has long been recognized as a major contributor to death in a variety of systemic neuromuscular disorders. More recently, it is increasingly apparent that diaphragm dysfunction is present in a high percentage of critically ill patients and is associated with increased morbidity and mortality. In these patients, diaphragm weakness is thought to develop from disuse secondary to ventilator-induced diaphragm inactivity and as a consequence of the effects of systemic inflammation, including sepsis. This form of critical illness-acquired diaphragm dysfunction impairs the ability of the respiratory pump to compensate for an increased respiratory workload due to lung injury and fluid overload, leading to sustained respiratory failure and death. This review examines the presentation, causes, consequences, diagnosis, and treatment of disorders that result in acquired diaphragm dysfunction during critical illness. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  8. CFD analysis of a diaphragm free-piston Stirling cryocooler

    Science.gov (United States)

    Caughley, Alan; Sellier, Mathieu; Gschwendtner, Michael; Tucker, Alan

    2016-10-01

    This paper presents a Computational Fluid Dynamics (CFD) analysis of a novel free-piston Stirling cryocooler that uses a pair of metal diaphragms to seal and suspend the displacer. The diaphragms allow the displacer to move without rubbing or moving seals. When coupled to a metal diaphragm pressure wave generator, the system produces a complete Stirling cryocooler with no rubbing parts in the working gas space. Initial modelling of this concept using the Sage modelling tool indicated the potential for a useful cryocooler. A proof-of-concept prototype was constructed and achieved cryogenic temperatures. A second prototype was designed and constructed using the experience gained from the first. The prototype produced 29 W of cooling at 77 K and reached a no-load temperature of 56 K. The diaphragm's large diameter and short stroke produces a significant radial component to the oscillating flow fields inside the cryocooler which were not modelled in the one-dimensional analysis tool Sage that was used to design the prototypes. Compared with standard pistons, the diaphragm geometry increases the gas-to-wall heat transfer due to the higher velocities and smaller hydraulic diameters. A Computational Fluid Dynamics (CFD) model of the cryocooler was constructed to understand the underlying fluid-dynamics and heat transfer mechanisms with the aim of further improving performance. The CFD modelling of the heat transfer in the radial flow fields created by the diaphragms shows the possibility of utilizing the flat geometry for heat transfer, reducing the need for, and the size of, expensive heat exchangers. This paper presents details of a CFD analysis used to model the flow and gas-to-wall heat transfer inside the second prototype cryocooler, including experimental validation of the CFD to produce a robust analysis.

  9. Thin-section multiplanar reformats from multidetector-row CT data: Utility for assessment of regional tumor extent in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Higashino, Takanori; Ohno, Yoshiharu; Takenaka, Daisuke; Watanabe, Hirokazu; Nogami, Munenobu; Ohbayashi, Chiho; Yoshimura, Masahiro; Satouchi, Miyako; Nishimura, Yoshihiro; Fujii, Masahiko; Sugimura, Kazuro

    2005-01-01

    Purpose: To determine the clinical utility of thin-section multiplanar reformats (MPRs) from multidetector-row CT (MDCT) data sets for assessing the extent of regional tumors in non-small cell lung cancer (NSCLC) patients. Materials and methods: Sixty consecutive NSCLC patients, who were considered candidates for surgical treatment, underwent contrast-enhanced MDCT examinations, surgical resection and pathological examinations. All MDCT examinations were performed with a 4-detector row computed tomography (CT). From each raw CT data set, 5 mm section thickness CT images (routine CT), 1.25 mm section thickness CT images (thin-section CT) and 1.25 mm section thickness sagittal (thin-section sagittal MPR) and coronal images (thin-section coronal MPR) were reconstructed. A 4-point visual score was used to assess mediastinal, interlobar and chest wall invasions on each image set. For assessment of utility in routine clinical practice, mean reading times for each image set were compared by means of Fisher's protected least significant difference (PLSD) test. A receiver operator characteristic (ROC) analysis was performed to determine the diagnostic capability of each of the image data sets. Finally, sensitivity, specificity and accuracy of the reconstructed images were compared by McNemar test. Results: Mean reading times for thin-section sagittal and coronal MPRs were significantly shorter than those for routine CT and thin-section CT (p < 0.05). Areas under the curve (Azs) showing interlobar invasion on thin-section sagittal and coronal MPRs were significantly larger than that on routine CT (p = 0.03), and the Az on thin-section sagittal MPR was also significantly larger than that on routine CT (p = 0.02). Accuracy of chest wall invasion by thin-section sagittal MPR was significantly higher than that by routine CT (p = 0.04). Conclusion: Thin-section multiplanar reformats from multidetector-row CT data sets are useful for assessing the extent of regional tumors in non

  10. Mosaic pattern of lung attenuation on thin-section CT : review of 31 cases

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Hi; An, Jee Hyun; Lee, Kye Young; Jee, Young Koo; Lee, Young Seok [Dankook Univ. College of Medicine, Choan (Korea, Republic of)

    1998-07-01

    To correlate radiologic findings with clinical findings in patients with a mosaic pattern of lung attenuation, as seen on thin-section CT. Materials and Methods : Thirty-one cases in which a mosaic pattern of lung attenuation was detected on combined expiratory and inspiratory scans of thin-section CT were retrospectively analyzed. Cases involving infiltrative lung disease were excluded. Both thin-section CT and clinical findings we reanalyzed and the relationship between the extent of the area of hyperlucency -as seen on expiratory scan- and physiologic parameters was evaluated. The subjects were 10 men and 21 women ranged in age from 25 to 76 (mean 50)years. Results : Twenty-nine patients with small airway disease, [chronic bronchitis and/or bronchiolitis(n=11),bronchiectasis(n=8), bronchial asthma(n=8), mycoplasmic pneumonitis(n=1) and hypersensitive pneumonitis(n=1),] and two patients with pulmonary vascular disease, [chronic pulmonary thromboembolism(n=1) and stenosis of the left upper pulmonary artery(n=1)] were included in our study. Commonly associated thin-section CT findings in the cases involving small airway disease(n=29) were bronchial wall thickening(n=25), nodular opacity(n=25), bronchial and bronchiolar dilatation(n=20) and small branching opacity(n=16). These findings were not observed in two patients with pulmonary vascular disease, though bronchial wall thickening was seen in the patient with chronic pulmonary thromboembolism. At expiratory scan level, there was statistical correlation between FEV1/FVC and the number of pulmonary segments(r= 0.982, p<0.05), but no correlation between FEV1/FVC and the percentage area of hyperlucency(r=0.803, p>0.05). Conclusion: The mosaic pattern of lung attenuation seen on thin-section CT is indicative of various diseases, involving small airways such as bronchiolitis, bronchitis, bronchiectasis and bronchial asthma, and vascular lung disease. Bronchial wall thickening and nodular opacity can be associated with

  11. Radial-Electric-Field Piezoelectric Diaphragm Pumps

    Science.gov (United States)

    Bryant, Robert G.; Working, Dennis C.; Mossi, Karla; Castro, Nicholas D.; Mane, Pooma

    2009-01-01

    In a recently invented class of piezoelectric diaphragm pumps, the electrode patterns on the piezoelectric diaphragms are configured so that the electric fields in the diaphragms have symmetrical radial (along-the-surface) components in addition to through-the-thickness components. Previously, it was accepted in the piezoelectric-transducer art that in order to produce the out-of-plane bending displacement of a diaphragm needed for pumping, one must make the electric field asymmetrical through the thickness, typically by means of electrodes placed on only one side of the piezoelectric material. In the present invention, electrodes are placed on both sides and patterned so as to produce substantial radial as well as through-the-thickness components. Moreover, unlike in the prior art, the electric field can be symmetrical through the thickness. Tests have shown in a given diaphragm that an electrode configuration according to this invention produces more displacement than does a conventional one-sided electrode pattern. The invention admits of numerous variations characterized by various degrees of complexity. Figure 1 is a simplified depiction of a basic version. As in other piezoelectric diaphragm pumps of similar basic design, the prime mover is a piezoelectric diaphragm. Application of a suitable voltage to the electrodes on the diaphragm causes it to undergo out-of-plane bending. The bending displacement pushes a fluid out of, or pulls the fluid into, a chamber bounded partly by the diaphragm. Also as in other diaphragm pumps in general, check valves ensure that the fluid flows only in through one port and only out through another port.

  12. Stylus type MEMS texture sensor covered with corrugated diaphragm

    Science.gov (United States)

    Tsukamoto, Takashiro; Asao, Hideaki; Tanaka, Shuji

    2017-09-01

    In this paper, a stylus type MEMS texture sensor covered with a corrugated palylene diaphragm, which prevent debris from jamming into the sensor without significant degradation of sensitivity and bandwidth, was reported. A new fabrication process using a lost-foil method to make the corrugated diaphragm on a 3-axis piezoresistive force sensor at wafer level has been developed. The texture sensor could detect the surface microstructure as small as about 10 \

  13. CONSTRUCTIVE ASPECTS INFLUENCE ON STIFFNESS OF DIAPHRAGM WALLS IN FRAME CONSTRUCTIONS WITH (LIGHT STEEL THIN –WALLED STRUCTURES

    Directory of Open Access Journals (Sweden)

    M. V. Savytskyi

    2010-10-01

    Full Text Available The dependences of influence of structural features of diaphragms of lightweight steel framing braced wall structures on their stiffness are determined. On the basis of dependences the procedure for estimation of stiffness of a diaphragm of any configuration that allows making decisions for maintenance of building stiffness is developed.

  14. Thin, Flexible Secondary Li-Ion Paper Batteries

    KAUST Repository

    Hu, Liangbing

    2010-10-26

    There is a strong interest in thin, flexible energy storage devices to meet modern society needs for applications such as interactive packaging, radio frequency sensing, and consumer products. In this article, we report a new structure of thin, flexible Li-ion batteries using paper as separators and free-standing carbon nanotube thin films as both current collectors. The current collectors and Li-ion battery materials are integrated onto a single sheet of paper through a lamination process. The paper functions as both a mechanical substrate and separator membrane with lower impedance than commercial separators. The CNT film functions as a current collector for both the anode and the cathode with a low sheet resistance (∼5 Ohm/sq), lightweight (∼0.2 mg/cm2), and excellent flexibility. After packaging, the rechargeable Li-ion paper battery, despite being thin (∼300 μm), exhibits robust mechanical flexibility (capable of bending down to <6 mm) and a high energy density (108 mWh/g). © 2010 American Chemical Society.

  15. Diaphragm motion quantification in megavoltage cone-beam CT projection images.

    Science.gov (United States)

    Chen, Mingqing; Siochi, R Alfredo

    2010-05-01

    To quantify diaphragm motion in megavoltage (MV) cone-beam computed tomography (CBCT) projections. User identified ipsilateral hemidiaphragm apex (IHDA) positions in two full exhale and inhale frames were used to create bounding rectangles in all other frames of a CBCT scan. The bounding rectangle was enlarged to create a region of interest (ROI). ROI pixels were associated with a cost function: The product of image gradients and a gradient direction matching function for an ideal hemidiaphragm determined from 40 training sets. A dynamic Hough transform (DHT) models a hemidiaphragm as a contour made of two parabola segments with a common vertex (the IHDA). The images within the ROIs are transformed into Hough space where a contour's Hough value is the sum of the cost function over all contour pixels. Dynamic programming finds the optimal trajectory of the common vertex in Hough space subject to motion constraints between frames, and an active contour model further refines the result. Interpolated ray tracing converts the positions to room coordinates. Root-mean-square (RMS) distances between these positions and those resulting from an expert's identification of the IHDA were determined for 21 Siemens MV CBCT scans. Computation time on a 2.66 GHz CPU was 30 s. The average craniocaudal RMS error was 1.38 +/- 0.67 mm. While much larger errors occurred in a few near-sagittal frames on one patient's scans, adjustments to algorithm constraints corrected them. The DHT based algorithm can compute IHDA trajectories immediately prior to radiation therapy on a daily basis using localization MVCBCT projection data. This has potential for calibrating external motion surrogates against diaphragm motion.

  16. Clinical and pulmonary thin-section CT findings in acute Klebsiella Pneumoniae pneumonia

    International Nuclear Information System (INIS)

    Okada, Fumito; Ando, Yumiko; Honda, Koichi; Nakayama, Tomoko; Kiyonaga, Maki; Ono, Asami; Tanoue, Shuichi; Maeda, Toru; Mori, Hiromu

    2009-01-01

    The aim of this study was to assess the clinical and pulmonary thin-section CT findings in patients with acute Klebsiella pneumoniae pneumonia. We retrospectively evaluated thin-section CT examinations performed between January 1991 and December 2007 from 962 patients with acute Klebsiella pneumoniae pneumonia. Seven hundred and sixty-four cases with concurrent infectious diseases were excluded. Thus, our study group comprised 198 patients (118 male, 80 female; age range 18-97 years, mean age 61.5). Underlying diseases and clinical findings were assessed. Parenchymal abnormalities were evaluated along with the presence of enlarged lymph nodes and pleural effusion. CT findings in patients with acute Klebsiella pneumoniae pneumonia consisted mainly of ground-glass attenuation (100%), consolidation (91.4%), and intralobular reticular opacity (85.9%), which were found in the periphery (96%) of both sides of the lungs (72.2%) and were often associated with pleural effusion (53%). The underlying conditions in patients with Klebsiella pneumoniae pneumonia were alcoholism or smoking habit. (orig.)

  17. Clinical and pulmonary thin-section CT findings in acute Klebsiella Pneumoniae pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Fumito [Oita University Faculty of Medicine, Department of Diagnostic and Interventional Radiology, Oita (Japan); Oita University Faculty of Medicine, Department of Radiology, Oita (Japan); Ando, Yumiko; Honda, Koichi; Nakayama, Tomoko; Kiyonaga, Maki; Ono, Asami; Tanoue, Shuichi; Maeda, Toru; Mori, Hiromu [Oita University Faculty of Medicine, Department of Diagnostic and Interventional Radiology, Oita (Japan)

    2009-04-15

    The aim of this study was to assess the clinical and pulmonary thin-section CT findings in patients with acute Klebsiella pneumoniae pneumonia. We retrospectively evaluated thin-section CT examinations performed between January 1991 and December 2007 from 962 patients with acute Klebsiella pneumoniae pneumonia. Seven hundred and sixty-four cases with concurrent infectious diseases were excluded. Thus, our study group comprised 198 patients (118 male, 80 female; age range 18-97 years, mean age 61.5). Underlying diseases and clinical findings were assessed. Parenchymal abnormalities were evaluated along with the presence of enlarged lymph nodes and pleural effusion. CT findings in patients with acute Klebsiella pneumoniae pneumonia consisted mainly of ground-glass attenuation (100%), consolidation (91.4%), and intralobular reticular opacity (85.9%), which were found in the periphery (96%) of both sides of the lungs (72.2%) and were often associated with pleural effusion (53%). The underlying conditions in patients with Klebsiella pneumoniae pneumonia were alcoholism or smoking habit. (orig.)

  18. Restoration of Thickness, Density, and Volume for Highly Blurred Thin Cortical Bones in Clinical CT Images.

    Science.gov (United States)

    Pakdel, Amirreza; Hardisty, Michael; Fialkov, Jeffrey; Whyne, Cari

    2016-11-01

    In clinical CT images containing thin osseous structures, accurate definition of the geometry and density is limited by the scanner's resolution and radiation dose. This study presents and validates a practical methodology for restoring information about thin bone structure by volumetric deblurring of images. The methodology involves 2 steps: a phantom-free, post-reconstruction estimation of the 3D point spread function (PSF) from CT data sets, followed by iterative deconvolution using the PSF estimate. Performance of 5 iterative deconvolution algorithms, blind, Richardson-Lucy (standard, plus Total Variation versions), modified residual norm steepest descent (MRNSD), and Conjugate Gradient Least-Squares were evaluated using CT scans of synthetic cortical bone phantoms. The MRNSD algorithm resulted in the highest relative deblurring performance as assessed by a cortical bone thickness error (0.18 mm) and intensity error (150 HU), and was subsequently applied on a CT image of a cadaveric skull. Performance was compared against micro-CT images of the excised thin cortical bone samples from the skull (average thickness 1.08 ± 0.77 mm). Error in quantitative measurements made from the deblurred images was reduced 82% (p < 0.01) for cortical thickness and 55% (p < 0.01) for bone mineral mass. These results demonstrate a significant restoration of geometrical and radiological density information derived for thin osseous features.

  19. Disseminated dendriform pulmonary ossification associated with usual interstitial pneumonia: incidence and thin-section CT-pathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Sung; Chung, Myung Jin [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Seoul (Korea); Han, Joungho [Sungkyunkwan University School of Medicine, Department of Pathology, Seoul (Korea); Chung, Man Pyo [Sungkyunkwan University School of Medicine, Division of Pulmonary and Critical Care Medicine, Department of Medicine, Seoul (Korea); Choi, Yong Soo [Sungkyunkwan University School of Medicine, Division of Thoracic Surgery, Seoul (Korea)

    2005-08-01

    The aim of this work was to assess the incidence of disseminated pulmonary dendriform ossification in usual interstitial pneumonia and nonspecific interstitial pneumonia, and to correlate thin-section computed tomography (CT) and histopathologic findings. We retrospectively reviewed thin-section CT and pathologic specimens of biopsy-proven usual interstitial pneumonia (75 patients, 57 men and 18 women, mean age 60 years, range 29-83 years) and nonspecific interstitial pneumonia (44 patients, 9 men and 35 women, mean age 55 years, range 20-73 years). On review of CT and histopathologic specimens, diffuse dendriform ossification was identified in five (four men and one woman, age range 41-68 years, mean 58 years) of 75 patients (6.7%) with usual interstitial pneumonia. It was not seen in any of 44 patients with nonspecific interstitial pneumonia. With thin-section CT (osteoporosis window; window width 818, level 273), disseminated dendriform pulmonary ossification was detected as multiple tiny calcifications in bibasilar subpleural lungs (100% sensitive and 100% specific when compared with histopathologic findings as the gold standard). The thin-section CT finding of multiple tiny calcifications in bibasilar subpleural lungs might be of some help in the differential diagnosis between usual interstitial pneumonia and nonspecific interstitial pneumonia, considering they were not seen in any patients with nonspecific interstitial pneumonia (0%, 0/44) in our series. (orig.)

  20. Disseminated dendriform pulmonary ossification associated with usual interstitial pneumonia: incidence and thin-section CT-pathologic correlation

    International Nuclear Information System (INIS)

    Kim, Tae Sung; Chung, Myung Jin; Han, Joungho; Chung, Man Pyo; Choi, Yong Soo

    2005-01-01

    The aim of this work was to assess the incidence of disseminated pulmonary dendriform ossification in usual interstitial pneumonia and nonspecific interstitial pneumonia, and to correlate thin-section computed tomography (CT) and histopathologic findings. We retrospectively reviewed thin-section CT and pathologic specimens of biopsy-proven usual interstitial pneumonia (75 patients, 57 men and 18 women, mean age 60 years, range 29-83 years) and nonspecific interstitial pneumonia (44 patients, 9 men and 35 women, mean age 55 years, range 20-73 years). On review of CT and histopathologic specimens, diffuse dendriform ossification was identified in five (four men and one woman, age range 41-68 years, mean 58 years) of 75 patients (6.7%) with usual interstitial pneumonia. It was not seen in any of 44 patients with nonspecific interstitial pneumonia. With thin-section CT (osteoporosis window; window width 818, level 273), disseminated dendriform pulmonary ossification was detected as multiple tiny calcifications in bibasilar subpleural lungs (100% sensitive and 100% specific when compared with histopathologic findings as the gold standard). The thin-section CT finding of multiple tiny calcifications in bibasilar subpleural lungs might be of some help in the differential diagnosis between usual interstitial pneumonia and nonspecific interstitial pneumonia, considering they were not seen in any patients with nonspecific interstitial pneumonia (0%, 0/44) in our series. (orig.)

  1. Three-dimensional-CT imaging of colorectal disease with thin collimation helical CT scanning

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Koizumi, Koichi; Sakai, Tatsuya; Kai, Shunkichi; Takatsu, Kazuaki; Maruyama, Masakazu

    1998-01-01

    We have conducted research on three-dimensional (3D)-CT-colonoscopy with thin collimation helical CT scanning over the past three years. This has lately become a subject of special interest. 3D-CT-colonoscopy has three kinds of visualizing methods depending on the threshold setting of CT values. The first one is the virtual endoscopy method which is displayed in a similar fashion to colonoscopic images. The second one is the air image method using the air in the digestive tract as a contrast medium. The third one is the pseudo-tract method which has characteristics of both virtual endoscopy and the air image method and visualizes in a shape of the digestive tract. The image visualized by 3D-CT-colonoscopy is similar to that of conventional colonoscopy and barium enema study, which is obtained with minimal invasion to patients. Obvious advanced carcinomas were easily visualized, and even a small flat polyp measuring 5 mm in size, was able to be observed retrospectively. The characteristics of our method are that we can easily make an examination in a short time and with little dependence on expert technique. Also patients have little discomfort compared to that experienced during colonoscopy and barium enema study. Important features are as follows; long calculation time, insufficient air insufflation, fecal material in the patient''s bowel, whole abdominal scan, and spatial resolution. In the near future, a multislice CT scanner system will have ability to overcome these problems. Therefore, 3D-CT-colonoscopy might be applied in the future for first line examination as a mass screening for colorectal carcinoma. (author)

  2. Proof mass effects on spiral electrode d33 mode piezoelectric diaphragm-based energy harvester

    KAUST Repository

    Shen, Zhiyuan; Liu, Shuwei; Miao, Jianmin; Woh, Lye Sun; Wang, Zhihong

    2013-01-01

    This paper presents the characterization of an energy harvester using a piezoelectric diaphragm as the vibration energy conversion microstructure. The diaphragm containing the spiral electrode operates in the d33 mode. The energy harvesting performance of the diaphragm was characterized. The optimal resistance load and the working frequency were characterized. The resonance tuning and the energy harvesting enhancement due to a proof mass were verified. © 2013 IEEE.

  3. Forest thinnings for integrated lumber and paper production

    Science.gov (United States)

    J.Y. Zhu; C.T. Scott; R. Gleisner; D. Mann; D.W. Vahey; D.P. Dykstra; G.H. Quinn; L.L. Edwards

    2007-01-01

    Integrated lumber and paper productions using forest thinning materials from U.S. national forests can significantly reduce the cost of prescriptive thinning operations. Many of the trees removed during forest thinnings are in small-diameter classes (diameter at breast height

  4. Effect of flexure beam geometry and material on the displacement of piezo actuated diaphragm for micropump

    Science.gov (United States)

    Roopa, R.; Navin Karanth, P.; Kulkarni, S. M.

    2018-02-01

    In this paper, we present a COMSOL analysis of flexure diaphragm for piezo actuated valveless micropump. Diaphragms play an important role in micropumps, till now plane diaphragms are commonly used in micropumps. Use of compliant flexure hinges in diaphragm and other MEMS application is one of the new approach to achieving high deflection in diaphragm at low operating voltage. Flexures hinges in diaphragm acts as simply supported beam. Out-off plane compliance value and stiffness is considered for the selection of proper flexure for diaphragm. Diaphragm material also plays an important role in the diaphragm central deflection. Factor considered for diaphragm material selection is resilience; it is the ratio of yield stress to static modulus. Higher is the resilience will leads to higher deflection generated, it also imparts good compliance. Based on the resilience beryllium copper, stainless steel and brass materials are selected for diaphragm analysis. Simulations have been performed using COMSOL multiphysics. This study reports the effect of flexure hinge geometry and diaphragm material on the central deflection of diaphragms and compared with existing plane diaphragm. Simulation results illustrates that the deflection of three flexure diaphragm with 2mm width and 2mm length flexure is 6.75µm for stainless steel, 10.89 for beryllium copper and 12.10µm for brass, at 140V which is approximately twice that of plane diaphragm deflection. The maximum in both plane and three flexure diaphragm deflection is obtained for brass diaphragm compared to stainless steel and beryllium copper.

  5. Differences in the definition of internal target volumes using slow CT alone or in combination with thin-slice CT under breath-holding conditions during the planning of stereotactic radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Seki, Satoshi; Kunieda, Etsuo; Takeda, Atsuya; Nagaoka, Tomoaki; Deloar, Hossain M.; Kawase, Takatsugu; Fukada, Junichi; Kawaguchi, Osamu; Uematsu, Minoru; Kubo, Atsushi

    2007-01-01

    Purpose: To investigate how the delineations of the internal target volume (ITV) made from 'slow' CT alter with reference to 'thin-slice' CT. Materials and methods: Thin-slice CT images taken under breath-holding conditions and slow CT images taken under shallow-breathing conditions (8 s/image) of 11 lung cancers were used for this study. Five radiation oncologists delineated ITV of the 11 lesions using slow CT images (ITV1), and then redefined them with reference to thin-slice CT images (ITV2). SD-images (standard deviation image) were created for all patients from ITV images in order to visualize the regional variation of the ITVs. Results: The mean value of ITV2 was smaller than that initially defined by ITV1. There was no significant change in ITV1 and ITV2 between operators with regard to standard deviation in volume. There was a significant difference in the distribution of the ratio of ITV1 to ITV2 obtained on thin-slice CTs between cases with and without ground glass opacity. In cases without ground glass opacity there was a tendency for ITV2 to have a smaller volume than ITV1. Conclusions: Combined use of slow CT and thin-slice CT in delineation of ITV contours appeared to be useful in making adjustments for obscured tumor images caused by respiratory movement

  6. New Stethoscope With Extensible Diaphragm.

    Science.gov (United States)

    Takashina, Tsunekazu; Shimizu, Masashi; Muratake, Torakazu; Mayuzumi, Syuichi

    2016-08-25

    This study compared the diagnostic efficacy of the common suspended diaphragm stethoscope (SDS) with a new extensible diaphragm stethoscope (EDS) for low-frequency heart sounds. The EDS was developed by using an ethylene propylene diene monomer diaphragm. The results showed that the EDS enhanced both the volume and quality of low-frequency heart sounds, and improved the ability of examiners to auscultate such heart sounds. Based on the results of the sound analysis, the EDS is more efficient than the SDS. (Circ J 2016; 80: 2047-2049).

  7. Bronchiolitis obliterans syndrome: thin-section CT diagnosis of obstructive changes in infants and young children after lung transplantation.

    Science.gov (United States)

    Lau, D M; Siegel, M J; Hildebolt, C F; Cohen, A H

    1998-09-01

    To characterize the thin-section computed tomographic (CT) appearance of bronchiolitis fibrosa obliterans syndrome in infants and young children after lung transplantation. Thin-section CT studies in six patients with bronchiolitis obliterans syndrome (age range, 2 months to 5 1/2 years) and in 15 control patients without obstructive airway disease (age range, 2 months to 7 years) who underwent bilateral lung transplantation were retrospectively reviewed. The thin-section CT scans were obtained during quiet sleep at a median of 24 months (range, 6-36 months) after transplantation. The CT studies were evaluated for mosaic perfusion, bronchial dilatation, bronchial wall thickening, and mucous plugging Final diagnoses in all patients were based pulmonary function test results. Thin-section CT findings in the six patients with clinically proved bronchiolitis obliterans syndrome were mosaic perfusion in five (83%) bronchial dilation in three (50%), and bronchial wall thickening in one (17%). Of the 15 control patients with normal pulmonary function test results, six (40%) had mosaic perfusion; none had bronchial dilatation or bronchial wall thickening. Mucous plugging was not seen in either group. Only the association of bronchial dilatation with bronchiolitis obliterans syndrome was significant (P = .02). Infants and young children with bronchiolitis obliterans syndrome after lung transplantation are more likely to have CT abnormalities than those with normal pulmonary function test results.

  8. Quantification of Diaphragm Mechanics in Pompe Disease Using Dynamic 3D MRI.

    Directory of Open Access Journals (Sweden)

    Katja Mogalle

    Full Text Available Diaphragm weakness is the main reason for respiratory dysfunction in patients with Pompe disease, a progressive metabolic myopathy affecting respiratory and limb-girdle muscles. Since respiratory failure is the major cause of death among adult patients, early identification of respiratory muscle involvement is necessary to initiate treatment in time and possibly prevent irreversible damage. In this paper we investigate the suitability of dynamic MR imaging in combination with state-of-the-art image analysis methods to assess respiratory muscle weakness.The proposed methodology relies on image registration and lung surface extraction to quantify lung kinematics during breathing. This allows for the extraction of geometry and motion features of the lung that characterize the independent contribution of the diaphragm and the thoracic muscles to the respiratory cycle.Results in 16 3D+t MRI scans (10 Pompe patients and 6 controls of a slow expiratory maneuver show that kinematic analysis from dynamic 3D images reveals important additional information about diaphragm mechanics and respiratory muscle involvement when compared to conventional pulmonary function tests. Pompe patients with severely reduced pulmonary function showed severe diaphragm weakness presented by minimal motion of the diaphragm. In patients with moderately reduced pulmonary function, cranial displacement of posterior diaphragm parts was reduced and the diaphragm dome was oriented more horizontally at full inspiration compared to healthy controls.Dynamic 3D MRI provides data for analyzing the contribution of both diaphragm and thoracic muscles independently. The proposed image analysis method has the potential to detect less severe diaphragm weakness and could thus be used to determine the optimal start of treatment in adult patients with Pompe disease in prospect of increased treatment response.

  9. Design, Modeling and Optimization of a Piezoelectric Pressure Sensor based on a Thin-Film PZT Membrane Containing Nanocrystalline Powders

    Directory of Open Access Journals (Sweden)

    Vahid MOHAMMADI

    2009-11-01

    Full Text Available In this paper fabrication of a 0-3 ceramic/ceramic composite lead zirconate titanate, Pb(Zr0.52Ti0.48O3 thin film has been presented and then a pressure sensor based on multilayer thin-film PZT diaphragm contain of Lead Zirconate Titanate nanocrystalline powders was designed, modeled and optimized. Dynamics characteristics of this multilayer diaphragm have been investigated by ANSYS® FE software. By this simulation the effective parameters of the multilayer PZT diaphragm for improving the performance of a pressure sensor in different ranges of pressure are optimized. The optimized thickness ratio of PZT layer to SiO2 was given in the paper to obtain the maximum deflection of the multilayer thin-film PZT diaphragm. A 0-3 ceramic/ceramic composite lead zirconate titanate, Pb(Zr0.52Ti0.48O3 film has been developed to fabricate the pressure sensor by a hybrid sol gel process. PZT nanopowders fabricated via conventional sol gel method and uniformly dispersed in PZT precursor solution by an attrition mill. XRD analysis shows that perovskite structure would be formed due to the presence of a significant amount of ceramic nanopowders. This texture has a good effect on piezoelectric properties of perovskite structure. The film forms a strongly bonded network and less shrinkage occurs, so the films do not crack during process. Also the aspect ratio through this process would be increased. SEM micrographs indicated that PZT films were uniform, crack free and have a composite microstructure and a piezoelectric coefficient d31 of -40 pC.N-1 and d33 ranged from 50pm.N-1 to 60pm.N-1.

  10. Thin section helical CT findings of klastskin tumor and benign stricture: cholangiographic correlation

    International Nuclear Information System (INIS)

    Choi, Guk Myeong; Han, Joon Koo; Kim, Tae Kyoung; Choi, Byung Ihn; Kim, Sun Whe; Cho, Yun Ku; Han, Man Chung; Yeon, Kyung Mo

    1997-01-01

    The purpose of this study was 1) to describe the thin section helical CT findings of hilar cholangiocarcinoma and of benign strcture, and to discuss the differential points between the two disease entities and 2) using cholangiographic correlation, to evaluate the diagnostic accuracy of helical CT in determining the extent of hilar cholangiocarcinoma. Twenty-seven patients with hilar cholangiocarcinoma and eight with benign biliary dilatation were studied. All except four with hilar cholangiocarcinoma, who underwentCT using a conventional scanner, were studied with two-phase helical CT. In all patients, cholangiographs were obtained by digital fluoroscopy after the injection of contrast materials into PTBD catheters. The level of obstruction was classified according to Bismuth, and 35 CT scans were studied blindly and retrospectively by two radiologists. The findings were analyzed for the presence of tumor, and then divided into two groups(cholangiocarcinomas and benign strictures), and the positive predictive value was calculated. The CT images of klatskin tumor were analyzed with special emphasis on the level and shape of the hilar obstruction. The level of biliary obstruction and extent of the tumor were carefully correlated with the results of cholangiography. Thin-section spiral CT correctly identified all tumor mass as a focal wall thickening obliterating the lumen. On arterial/portal phase CT scanning, 81% of infilterative tumors showed high attenuation. In all patients, differentiation between benign stricture and klaskin tumor was possible;correct identification of the level of obstruction and extent of tumor, according to Bismuth's classification, was possible in 63% of cases. For correct diagnosis of hilar cholangiocarcinoma and differentiation of benign stricture, helical CT was highly accurate and effective. Because of limital Z-axis resolution, however, the exact intraductal extent of the tumor was less accorately diagnosed.=20

  11. Evaluation of Effective Diaphragm Area for Pneumatic Actuator

    International Nuclear Information System (INIS)

    Ryu, Hogeun; Han, Bongsub; Seon, Juhyoung

    2016-01-01

    The purpose of this study is to develop a methodology to calculate the exact effective diaphragm area using the results of diagnostic test to be performed in the evaluation of air operated valve performance. By using this developed methodology in pneumatic actuator performance evaluation, it can be reduce the possible errors arising from effective diaphragm area in the evaluation of performance of air operated valves. The performance assessment for the operability and structural integrity of air operated valves for the domestic nuclear power plant is in progress. One of the important parameters that determine the performance of the air operated valves is the effective diaphragm area of diaphragm type actuator. The effective diaphragm area is the actual area which the air pressure acting on the diaphragm. In general, the effective diaphragm area used for the performance evaluation of pneumatic actuator is provided by the manufacture or the actuator drawing. Flat type diaphragm was showed the difference between the measured value of EDA and the manufacture’s value, in the case of convoluted type diaphragm has showed that the measured value of EDA and manufacture’s value is almost the same. When evaluate a performance of a diaphragm actuator, accurate EDA is to be used because it is an important variable affecting the actuator performance. Particularly in the case of flat type diaphragm which EDA is changed in accordance with the stroke position, by using the EDA evaluation methodology developed in this study to minimize a possible error due to EDA when evaluating the performance of the air actuator

  12. Evaluation of Effective Diaphragm Area for Pneumatic Actuator

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Hogeun; Han, Bongsub; Seon, Juhyoung [SOOSAN INDUSTRIES, Seoul (Korea, Republic of)

    2016-10-15

    The purpose of this study is to develop a methodology to calculate the exact effective diaphragm area using the results of diagnostic test to be performed in the evaluation of air operated valve performance. By using this developed methodology in pneumatic actuator performance evaluation, it can be reduce the possible errors arising from effective diaphragm area in the evaluation of performance of air operated valves. The performance assessment for the operability and structural integrity of air operated valves for the domestic nuclear power plant is in progress. One of the important parameters that determine the performance of the air operated valves is the effective diaphragm area of diaphragm type actuator. The effective diaphragm area is the actual area which the air pressure acting on the diaphragm. In general, the effective diaphragm area used for the performance evaluation of pneumatic actuator is provided by the manufacture or the actuator drawing. Flat type diaphragm was showed the difference between the measured value of EDA and the manufacture’s value, in the case of convoluted type diaphragm has showed that the measured value of EDA and manufacture’s value is almost the same. When evaluate a performance of a diaphragm actuator, accurate EDA is to be used because it is an important variable affecting the actuator performance. Particularly in the case of flat type diaphragm which EDA is changed in accordance with the stroke position, by using the EDA evaluation methodology developed in this study to minimize a possible error due to EDA when evaluating the performance of the air actuator.

  13. Evaluating the effect of pressure on the diaphragm micro- electro-mechanical thickness and the amount of shift in medical applications

    Directory of Open Access Journals (Sweden)

    Nazli Zargarpour

    2017-04-01

    Full Text Available In this paper, the influence of design parameters on the sensitive microphone diaphragm for use in implantable medical applications is presented. The different parameters such as diaphragm shape, size, thickness and different applied pressures on the diaphragm has been considered. The effect of changes in these parameters on the displacement and stress in a variety of shapes of diaphragm is discussed. In order to design the optimal shape of the proposed diaphragm for the considered parameters, it has been simulated and analyzed in software COMSOL. According to the parameters, the diaphragm shapes of square, rectangular and oval with respect to the intended user, average central displacement in human hearing frequency range 20Hz-20KHz are nm 5. 5, nm2. 6, and nm 130 respectively . According to the results of the simulations, the oval-shaped diaphragm that has been studies in this paper, the possibility of implanted medical applications, performance is optimal than other shapes. In addition, the piezoelectric material is PZT which used in the design of the diaphragm.

  14. A free-piston Stirling cryocooler using metal diaphragms

    Science.gov (United States)

    Caughley, Alan; Sellier, Mathieu; Gschwendtner, Michael; Tucker, Alan

    2016-12-01

    A novel concept for a free-piston Stirling cryocooler has been proposed. The concept uses a pair of metal diaphragms to seal and suspend the displacer of a free-piston Stirling cryocooler. The diaphragms allow the displacer to move without rubbing or moving seals, potentially resulting in a long-life mechanism. When coupled to a metal diaphragm pressure wave generator, the system produces a complete Stirling cryocooler with no rubbing parts in the working gas space. Initial modelling of this concept using the Sage modelling tool indicates the potential for a useful cryocooler. A proof-of-concept prototype was constructed and achieved cryogenic temperatures. A second prototype was designed and constructed using the experience gained from the first. The prototype produced 29 W of cooling at 77 K and reached a no-load temperature of 56 K. Sage predicted the macroscopic behaviour of the prototype well but did not provide sufficient insights to improve performance significantly. This paper presents details of the development, modelling and testing of the proof-of-concept prototype and a second, improved prototype.

  15. Diaphragm users should follow 13 tips for best effectiveness.

    Science.gov (United States)

    Reese, M; Hatcher, R A

    1984-11-01

    The following 13 tips should be presented by family planning practitioners to diaphragm users: 1) the client must be able to feel her cervix; 2) the diaphragm should be checked for tears or holes before each use; 3) it should always be used with contraceptive jelly or cream; 4) petroleum products should not be used with the diaphragm; 5) the device should be inserted in plentyof time before intercourse; 6) it should be used at every intercourse; 7) to insert the diaphragm, use 1 hand to hold the cup down and the dome up, fold the diaphragm in half, push it toward the back of the vagina, and tuck the front rim behind the pubic bone; 8) check placement of the diaphragm by ensuring that the soft rubber dome covers the cervix and the front rim is firmly behind the pubic bone; 9) be aware that the diaphragm is probably not in the correct position if it causes discomfort; 10) do not douche with the diaphragm in place; 11) leave the device in place for a least 6 hours after intercourse; 12) remove the diaphragm by hooking the index finger behind the front rim and pulling down and out, being careful not to puncture the diaphragm; and 13) wash the diaphragm with mild soap and water and store it in a platic container away from heat. If patients gain or lose more than 10 pounds, have a pregnancy or pelvic surgery, suspect that their diaphragm is too large or too small, or are experiencing discomfort or pain, they should have the fit checked. Finally, since several cases of toxic shock syndrome have occured in diaphragm users, patients should avoid leaving the diaphragm in place more than 24 hours and avoid its use during menstruation.

  16. Investigation of PVdF active diaphragms for synthetic jets

    Science.gov (United States)

    Bailo, Kelly C.; Brei, Diann E.; Calkins, Frederick T.

    2000-06-01

    Current research has shown that aircraft can gain significant aerodynamic performance benefits by employing active flow control (AFC). One of the enabling technologies of AFC is the synthetic jet. Synthetic jets, also known as zero-net-mass flux actuators, act as bi-directional pumps injecting high momentum air into the local aerodynamic flow. Previous work has concentrated on high frequency synthetic jets based on piezoelectric active diaphragms such as Thunder actuators. Low frequency synthetic jets present a unique challenge requiring large displacements, which current technology has difficulty meeting. Boeing is investigating novel shaped low frequency synthetic jets that can modify the flow over fixed aircraft wings. This paper present the initial study of two promising active diaphragm concepts: a crescent shape and an opposing bender shape. These active diaphragms were numerically modeled utilizing the general-purpose finite element code ABAQUS. Using the ABAQUS results, the dynamic volume change within each jet was calculated and incorporated into an analytical linear Bernoulli model to predict the velocities and pressures at the nozzle. Simulations were performed to determine trends to assist in selection of prototype configurations. Prototypes of both diaphragm concepts were constructed from polyvinylidene fluoride and experimentally tested at Boeing with promising results.

  17. Experimental device for measuring the dynamic properties of diaphragm motors

    Science.gov (United States)

    Fojtášek, Kamil; Dvořák, Lukáš; Mejzlík, Jan

    The subject of this paper is to design and description of the experimental device for the determination dynamic properties of diaphragm pneumatic motors. These motors are structurally quite different from conventional pneumatic linear cylinders. The working fluid is typically compressed air, the piston of motor is replaced by an elastic part and during the working cycle there is a contact of two elastic environments. In the manufacturers catalogs of these motors are not given any working characteristics. Description of the dynamic behavior of diaphragm motor will be used for verification of mathematical models.

  18. Eventration of diaphragm with a rare association

    Directory of Open Access Journals (Sweden)

    Syed Shafiq

    2014-01-01

    Full Text Available Eventration of the diaphragm is a rare anomaly of unknown origin characterized by a permanent high position of one or rarely both the leaflets of the diaphragm, providing a potential space for the displacement of abdominal viscera on the affected side(s. The etiology, diagnosis, and management of this condition remains a controversial subject. We report a rare case of infiltrating squamous cell carcinoma of the esophagus in a patient with eventration of the diaphragm and gastric volvulus who presented to us with retrosternal discomfort. To the best of our knowledge, this rare association has not been reported in the literature, although one case of esophageal adenocarcinoma arising from Barrett′s esophagus in association with eventration of the diaphragm has been reported previously. This case again emphasis the varied associations of an eventration of the diaphragm.

  19. Thin, Flexible Secondary Li-Ion Paper Batteries

    KAUST Repository

    Hu, Liangbing; Wu, Hui; La Mantia, Fabio; Yang, Yuan; Cui, Yi

    2010-01-01

    , flexible Li-ion batteries using paper as separators and free-standing carbon nanotube thin films as both current collectors. The current collectors and Li-ion battery materials are integrated onto a single sheet of paper through a lamination process

  20. Efficacy evaluation of laparoscopy assisted ultrasound guided radiofrequency ablation in the treatment of hepatocellular carcinoma beneath the diaphragm

    Directory of Open Access Journals (Sweden)

    Song WANG

    2017-06-01

    Full Text Available Objective To explore the feasibility, safety and efficacy of laparoscopy assisted ultrasound guided radiofrequency ablation (RFA in the treatment of hepatocellular carcinoma (HCC beneath the diaphragm. Methods Twenty- three consecutive patients with solitary HCC beneath the diaphragm were treated by laparoscopy assisted ultrasound guided RFA in the Chinese PLA General Hospital from January 2013 to March 2016. We observed the perioperative complications and followed- up long-term effect. Results All the 23 patients successfully underwent laparoscopy assisted ultrasound guided radiofrequency ablation. No serious complications such as massive hemorrhage, biliary fistula and severe pleural effusion, hemopneumothorax occurred in the patients during perioperative period. CT examination 2-3 days after the operation revealed that the tumor was completely covered by the ablation area. Besides, the survival condition was satisfactory during follow-up period of 9-38 months. Conclusion Laparoscopy-assisted ultrasound-guided radiofrequency ablation is effective and safe for HCC beneath the diaphragm. DOI: 10.11855/j.issn.0577-7402.2017.05.16

  1. Investigation into the behaviour of concrete anchored diaphragm walls under earthquake condition

    International Nuclear Information System (INIS)

    Saba, H. R.; Rahaii, A. R.

    2003-01-01

    Diaphragm walls are frequently used in civil Engineering projects. Considering the variety and important volume of consumed materials (concrete, anchors and soil), one of the important factors for design and construction of these walls, are their behaviour under different executive, and loading conditions. In this paper, various models of concrete diaphragms with different number of anchors and soil parameters under static and dynamic loading have been investigated using finite element method with nonlinear models. Results including the internal forces in diaphragm walls, variation of forces in the anchors, shape of the sliding surface and variation of pressure in soil are obtained and compared. An experimental tool with suitable measurement systems for determining the pressure and internal forces was designed and realised. Also with similitude and dimensional analyses, diaphragms with different number of anchors were built and set on the shaking table test and experimented under different accelograms. Finally results of nonlinear dynamic analysis were compared with experimental results

  2. Verification on reliability of diaphragm seal

    International Nuclear Information System (INIS)

    Ide, Hiroshi; Sakuta, Yoshiyuki; Hanawa, Yoshio; Tsuji, Tomoyuki; Tsuboi, Kazuaki; Nagao, Yoshiharu; Miyazawa, Masataka

    2009-06-01

    The main body of the JMTR is composed of reactor pressure vessel, core and reactor pool. At the bottom of the reactor pool, the Diaphragm-seal (2.6m outer diameter, 2m inner diameter, thickness 1.5mm) of the JMTR made of stainless steel is installed to prevent the water leak of the reactor pool and to absorb the expansion of the reactor pressure vessel due to pressure and temperature changes. In the long-term maintenance plans drawn up in 2004, it is required that the visual inspection for the diaphragm-seal should be carried out in 2007 and that the inspection should be carried out every around five-year. Therefore, prior to the refurbishment of the JMTR, the inspection device which is a deposition-collection apparatus with underwater-camera was developed, and the visual inspection was carried out to confirm the soundness of the diaphragm-seal. As a result, harmful flaws and/or corrosions were not inspected in the visual inspection, and the soundness of the diaphragm seal was confirmed. In future, the long-term integrity of the diaphragm-seal will could be achieved by conducting the periodic inspection. (author)

  3. Thin-section chest CT findings in systemic lupus erythematosus with antiphospholipid syndrome: A comparison with systemic lupus erythematosus without antiphospholipid syndrome

    International Nuclear Information System (INIS)

    Oki, Hodaka; Aoki, Takatoshi; Saito, Kazuyoshi; Yamashita, Yoshiko; Hanamiya, Mai; Hayashida, Yoshiko; Tanaka, Yoshiya; Korogi, Yukunori

    2012-01-01

    Purpose: To assess thin-section chest CT findings in systemic lupus erythematosus (SLE) with antiphospholipid syndrome (APS), in comparison with SLE without APS. Materials and methods: We retrospectively reviewed the medical records and thin-section CT findings of 17 consecutive patients with an established diagnosis of SLE with APS, comparing with 37 consecutive SLE patients without APS, between 2004 and 2008, and patients who had other autoimmune disease, such as Sjögren syndrome, were excluded. No significant differences were seen between the two groups in age, gender, smoking habits, or history of steroid pulse and biological therapy. CT images of 2 mm thickness obtained with a 16- or 64-detector row CT were retrospectively evaluated by two radiologists in consensus on ultra high-resolution gray-scale monitors. Results: The frequency of thin-section CT abnormalities was higher in SLE with APS group (82%) than in SLE without APS group (43%). Ground-glass opacity (59%), architectural distortion (47%), reticulation (41%), enlarged peripheral pulmonary artery (29%), and mosaic attenuation (29%) were significantly more common in the SLE with APS group than in the SLE without APS group (Fisher's exact test, p < 0.01). Conclusion: SLE patients with APS have increased prevalence of thin-section chest CT abnormalities than those without APS.

  4. Paper-based transparent flexible thin film supercapacitors

    Science.gov (United States)

    Gao, Kezheng; Shao, Ziqiang; Wu, Xue; Wang, Xi; Zhang, Yunhua; Wang, Wenjun; Wang, Feijun

    2013-05-01

    Paper-based transparent flexible thin film supercapacitors were fabricated using CNF-[RGO]n hybrid paper as an electrode material and charge collector. Owing to the self-anti-stacking of distorted RGO nanosheets and internal electrolyte nanoscale-reservoirs, the device exhibited good electrochemical performance (about 1.73 mF cm-2), and a transmittance of about 56% (at 550 nm).Paper-based transparent flexible thin film supercapacitors were fabricated using CNF-[RGO]n hybrid paper as an electrode material and charge collector. Owing to the self-anti-stacking of distorted RGO nanosheets and internal electrolyte nanoscale-reservoirs, the device exhibited good electrochemical performance (about 1.73 mF cm-2), and a transmittance of about 56% (at 550 nm). Electronic supplementary information (ESI) available: Experimental, TEM image, IR spectra, and XRD spectra of cellulose nanofibers, TEM image, and XRD spectra of RGO, graphite, GO nanosheets, CNF paper, and CNF-[RGO]20 hybrid paper, high-resolution C1s spectra of GO, Raman spectra of GO nanosheets, cross-sectional FESEM image of CNF-[RGO]20 hybrid paper and stress-strain curve of T-SC-20. See DOI: 10.1039/c3nr00674c

  5. D33 mode piezoelectric diaphragm based acoustic transducer with high sensitivity

    KAUST Repository

    Shen, Zhiyuan; Lu, Jingyu; Tan, Cheewee; Miao, Jianmin; Wang, Zhihong

    2013-01-01

    This paper presents the design, fabrication, and characterization of an acoustic transducer using a piezoelectric freestanding bulk diaphragm as the sensing element. The diaphragm bearing the spiral electrode operates in d 33 mode, which allows the in-plane deformation of the diaphragm to be converted to the out-of-plane deformation and generates an acoustic wave in the same direction. A finite element code is developed to reorient the material polarization distribution according to the poling field calculated. The first four resonance modes have been simulated and verified by impedance and velocity spectra. The sensitivity and the sound pressure level of the transducer were characterized. The realized sensitivity of 126.21 μV/Pa at 1 kHz is nearly twenty times of the sensitivity of a sandwich d31 mode transducer. © 2012 Elsevier B.V.

  6. To detect anomalies in diaphragm walls

    NARCIS (Netherlands)

    Spruit, R.

    2015-01-01

    Diaphragm walls are potentially ideal retaining walls for deep excavations in densely built-up areas, as they cause no vibrations during their construction and provide structural elements with high strength and stiffness. In the recent past, however, several projects using diaphragm walls as soil

  7. Congenital duodenal diaphragm in eight children

    International Nuclear Information System (INIS)

    Nawaz, Akhtar; Matta, Hilal; Jacobsz, Alic; Al-Salem, Ahmad H.; Trad, Omar

    2004-01-01

    Congenital duodenal obstruction (CDO) is common and usually easy to diagnose cause of intestinal obstruction in the newborn, except when the cause of the obstruction is duodenal diaphragm. We describe our experience with eight children who had intrinsic duodenal obstruction secondary to a duodenal diaphragm. The medical record of 22 children with the diagnosis of congenital intrinsic duodenal were reviewed for age, sex, gestation, birth weight, clinical features, associated anomalies, method of diagnosis, treatment and outcome. Operative findings and procedures were obtained from the operative notes. Eight of 22 children (36.4%) had congenital duodenal diaphragm (CDD). In all children, the diagnosis was made from the plain abdominal X-ray, which showed the classic double-bubble appearence, and barium meal, which showed duodenal obstruction. Four patients had associated anomalies, including two with Down's syndrome intraoperatively, five patients were found to have duodenal diaphragm with a central hole, while the other three had complete duodenal diaphragms. Postoperatively, all patients did well. Six required total parenteral nutrition. The 100% survival rate among these children is comparable to that in Western countries, and can be attributed to the lack of major associated abnormalities, good perioperative management, and the availability of total parenteral nutrition. (author)

  8. Shallow and deep breath lung tumor volume as estimated by spiral volumetric CT in comparison to standard axial CT using virtual simulation

    International Nuclear Information System (INIS)

    Quader, M.A.; Kalend, A.M.; Deutsch, M.; Greenberger, J.S.

    1995-01-01

    Purpose/Objective: In order to assess an individual patient tumor volume (TV) margins that are sufficient to design a beam-eye-view (BEW) conformal portal, the radiographic extent of gross tumor volume (GTV) dimensions and its fluctuation with breathing are measured by fast spiral CT scanning of patients treated for Stage II, III lung cancers using 5-6 field multi-collimated conformal beams. Materials and Methods: Over the course of conformal radiotherapy for lung cancer, a full thorax CT scans of the patient were taken by conventional axial CT scanning with patients immobilized in the treatment position and breathing normally. Patient(s) with good pulmonary function test (PFT) status were selected to perform deep breathing and re-scanned by fast spiral techniques in order to re-acquire the tomographic variation in the (GTV) with breathing. A Picker spiral ZAP-100 software running on the AQSim-PQ-2000 was used with a variable helical pitch of 1.0, 1.5 and 2.0. The variable pitch spirals were limited to tumor bed, diaphragm and lung apex area for measurements. Effect of breathing motion along x,y,z direction were then assessed for each beam-eye-view portal as seen in digitally reconstructed radiography (DRR) at the treated gantry angle. Results: Comparison of axial and spiral scans shows the progression of lung and diaphram motion with breathing can be gauged better in spiral scans. The movement of the diaphragm during shallow breathing has been found to be 2-3cm by measuring the distance between the most inferior and superior slices where diaphragm is present. The variation of the tumor dimensions along AP/PA and lateral direction seems to be less sensitive to breathing than those along inferior-superior direction. Conclusion: The fast spiral CT scanning is sensitive to patient lung motion and can be used to determine the fluctuations of the gross tumor volume with breathing. The extent of the fluctuation is location dependent and increases as one moves from the

  9. Pulmonary parenchyma segmentation in thin CT image sequences with spectral clustering and geodesic active contour model based on similarity

    Science.gov (United States)

    He, Nana; Zhang, Xiaolong; Zhao, Juanjuan; Zhao, Huilan; Qiang, Yan

    2017-07-01

    While the popular thin layer scanning technology of spiral CT has helped to improve diagnoses of lung diseases, the large volumes of scanning images produced by the technology also dramatically increase the load of physicians in lesion detection. Computer-aided diagnosis techniques like lesions segmentation in thin CT sequences have been developed to address this issue, but it remains a challenge to achieve high segmentation efficiency and accuracy without much involvement of human manual intervention. In this paper, we present our research on automated segmentation of lung parenchyma with an improved geodesic active contour model that is geodesic active contour model based on similarity (GACBS). Combining spectral clustering algorithm based on Nystrom (SCN) with GACBS, this algorithm first extracts key image slices, then uses these slices to generate an initial contour of pulmonary parenchyma of un-segmented slices with an interpolation algorithm, and finally segments lung parenchyma of un-segmented slices. Experimental results show that the segmentation results generated by our method are close to what manual segmentation can produce, with an average volume overlap ratio of 91.48%.

  10. 4D-CT Lung registration using anatomy-based multi-level multi-resolution optical flow analysis and thin-plate splines.

    Science.gov (United States)

    Min, Yugang; Neylon, John; Shah, Amish; Meeks, Sanford; Lee, Percy; Kupelian, Patrick; Santhanam, Anand P

    2014-09-01

    The accuracy of 4D-CT registration is limited by inconsistent Hounsfield unit (HU) values in the 4D-CT data from one respiratory phase to another and lower image contrast for lung substructures. This paper presents an optical flow and thin-plate spline (TPS)-based 4D-CT registration method to account for these limitations. The use of unified HU values on multiple anatomy levels (e.g., the lung contour, blood vessels, and parenchyma) accounts for registration errors by inconsistent landmark HU value. While 3D multi-resolution optical flow analysis registers each anatomical level, TPS is employed for propagating the results from one anatomical level to another ultimately leading to the 4D-CT registration. 4D-CT registration was validated using target registration error (TRE), inverse consistency error (ICE) metrics, and a statistical image comparison using Gamma criteria of 1 % intensity difference in 2 mm(3) window range. Validation results showed that the proposed method was able to register CT lung datasets with TRE and ICE values <3 mm. In addition, the average number of voxel that failed the Gamma criteria was <3 %, which supports the clinical applicability of the propose registration mechanism. The proposed 4D-CT registration computes the volumetric lung deformations within clinically viable accuracy.

  11. Materials for Slack Diaphragms

    Science.gov (United States)

    Puschmann, Traute

    1940-01-01

    This report deals with systematic experiments carried out on five diaphragm materials with different pretreatment, for the purpose of ascertaining the suitability of such materials for slack diaphragms. The relationship of deflection and load, temperature and moisture, was recorded. Of the explored materials, synthetic leather, balloon cloth, goldbeaters skin, Igelit and Buna, synthetic leather treated with castor oil is the most suitable material for the small pressure range required. Balloon cloth is nearly as good, while goldbeaters skin, Igelit and Buna were found to be below the required standards.

  12. Benefit of computer-aided detection analysis for the detection of subsolid and solid lung nodules on thin- and thick-section CT.

    Science.gov (United States)

    Godoy, Myrna C B; Kim, Tae Jung; White, Charles S; Bogoni, Luca; de Groot, Patricia; Florin, Charles; Obuchowski, Nancy; Babb, James S; Salganicoff, Marcos; Naidich, David P; Anand, Vikram; Park, Sangmin; Vlahos, Ioannis; Ko, Jane P

    2013-01-01

    The objective of our study was to evaluate the impact of computer-aided detection (CAD) on the identification of subsolid and solid lung nodules on thin- and thick-section CT. For 46 chest CT examinations with ground-glass opacity (GGO) nodules, CAD marks computed using thin data were evaluated in two phases. First, four chest radiologists reviewed thin sections (reader(thin)) for nodules and subsequently CAD marks (reader(thin) + CAD(thin)). After 4 months, the same cases were reviewed on thick sections (reader(thick)) and subsequently with CAD marks (reader(thick) + CAD(thick)). Sensitivities were evaluated. Additionally, reader(thick) sensitivity with assessment of CAD marks on thin sections was estimated (reader(thick) + CAD(thin)). For 155 nodules (mean, 5.5 mm; range, 4.0-27.5 mm)-74 solid nodules, 22 part-solid (part-solid nodules), and 59 GGO nodules-CAD stand-alone sensitivity was 80%, 95%, and 71%, respectively, with three false-positives on average (0-12) per CT study. Reader(thin) + CAD(thin) sensitivities were higher than reader(thin) for solid nodules (82% vs 57%, p thick), reader(thick) + CAD(thick), reader(thick) + CAD(thin) were 40%, 58% (p thick); false-positive rates were 1.17, 1.19, and 1.26 per case for reader(thick), reader(thick) + CAD(thick), and reader(thick) + CAD(thin), respectively. Detection of GGO nodules and solid nodules is significantly improved with CAD. When interpretation is performed on thick sections, the benefit is greater when CAD marks are reviewed on thin rather than thick sections.

  13. Ultrasonographic Assessment of Diaphragm Function in Critically Ill Subjects.

    Science.gov (United States)

    Umbrello, Michele; Formenti, Paolo

    2016-04-01

    The majority of patients admitted to the ICU require mechanical ventilation as a part of their process of care. However, mechanical ventilation itself or the underlying disease can lead to dysfunction of the diaphragm, a condition that may contribute to the failure of weaning from mechanical ventilation. However, extended time on the ventilator increases health-care costs and greatly increases patient morbidity and mortality. Nevertheless, symptoms and signs of muscle disease in a bedridden (or bed rest-only) ICU patient are often difficult to assess because of concomitant confounding factors. Conventional assessment of diaphragm function lacks specific, noninvasive, time-saving, and easily performed bedside tools or requires patient cooperation. Recently, the use of ultrasound has raised great interest as a simple, noninvasive method of quantification of diaphragm contractile activity. In this review, we discuss the physiology and the relevant pathophysiology of diaphragm function, and we summarize the recent findings concerning the evaluation of its (dys)function in critically ill patients, with a special focus on the role of ultrasounds. We describe how to assess diaphragm excursion and diaphragm thickening during breathing and the meaning of these measurements under spontaneous or mechanical ventilation as well as the reference values in health and disease. The spread of ultrasonographic assessment of diaphragm function may possibly result in timely identification of patients with diaphragm dysfunction and to a potential improvement in the assessment of recovery from diaphragm weakness. Copyright © 2016 by Daedalus Enterprises.

  14. Bubble-like appearances are characteristic thin-section CT findings of adenocarcinoma

    International Nuclear Information System (INIS)

    Kojima, Yoko; Saito, Haruhiro; Ito, Hiroyuki

    2008-01-01

    Adenocarcinomas are often diagnosed as old inflammatory lesions which are sometimes overlooked. Some of these adenocarcinomas display characteristic thin-section computed tomography (TS-CT) findings. We reported on these bubble-like appearances (BLA). We studied the BLA characteristics of adenocarcinomas. We reviewed the TS-CT findings of 17 (6 men, 11 women) cases of adenocarcinoma with bubble-like appearances. All 17 patients had undergone surgery between August 2003 and March 2007. We studied correlations between the TS-CT findings, the pathological findings and the clinical characteristics. The average tumor diameter was 35.4 mm. The definition of BLA is; having a irregular shape with straight margins, peripheral ground-glass opacity (GGO), dilated air bronchograms (more than 3), prominent pleural indentation. The pathological characteristics of tumors with BLA were; peripheral bronchioloalveolar cell carcinoma (BAC) patterns, almost total collapse (about 80% of the tumor area), and several ectatic small bronchi. Six cases were initially overlooked, because the TS-CT findings appeared as old inflammation. The average tumor doubling time was 1167 days. After resection, there have been no recurrences. On TS-CT images, BLA type adenocarcinomas appear as irregular in shape and they have a very slow doubling time. These types of lesions require careful attention because they are often diagnosed as old inflammatory scarring. (author)

  15. HERCA Position Paper. The process of CT dose optimisation through education and training and role of CT Manufacturers - October 2014. Addendum to HERCA CT Position paper: The process of CT dose optimisation through education and training and the role of the manufacturers - November 2015

    International Nuclear Information System (INIS)

    2014-10-01

    CT is the most important source of exposures to radiation in most developed countries today. For this reason CT dose optimisation is of great importance. In this position paper four main stakeholders who are involved in CT dose optimisation are identified. These are the CT manufacturers, the medical doctors, the CT technologists and the medical physicists. HERCA has been working together with the CT manufacturers and COCIR since 2010 following a self-commitment provided by COCIR in 2011. A number of dose optimisation and management tools have been developed by the CT manufacturers and are now available on modern CT scanners. These are presented in this paper. The process of CT dose optimisation can only be achieved if all the stakeholders involved work together as a team and are educated and trained in the use of CT dose optimisation and management tools. The CT manufacturers have an important role in this process. They need to ensure that their staff is properly trained, they need to provide proper education and training to the other three stakeholders involved and these three stakeholders need to find the time and be willing to be trained. This is clearly stated in this position paper with the aim of ensuring appropriate and effective use of CT imaging equipment. On 1 April 2015, HERCA organised a multi-stakeholder meeting kindly hosted by the French Nuclear Safety Authority (ASN) in its premises in Paris. The stakeholders included: - COCIR, supported by the main manufacturers of CT equipment (GE, Philips, Siemens and Toshiba), - The professional organisations: ESR, ESPR, EFRS, EANM, ESTRO and EFOMP, - The international organisations IAEA, EC, and the US FDA (present as observers). The objective of the meeting was to exchange views with a variety of key stakeholders on issues with regard to the optimised use of computed tomography (CT) scanners. The ultimate goal of this focus on dose optimisation is to ensure the best patient care by providing an optimised

  16. One stage resection of spontaneous rupture of hepatocellular carcinoma in the triangular ligament with diaphragm invasion: case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Park Kwang-Kuk

    2012-09-01

    Full Text Available Abstract A spontaneous rupture of hepatocellular carcinoma (HCC can lead to extensive hemorrhage and is a rare but life-threatening event. A 58-year-old male patient with no history of trauma presented at our institution with severe epigastric pain and abdominal distension for 6 h. His blood pressure was a 60/40 mmHg, and pulse rate was 132/min. Abdominal contrast enhanced computed tomography (CT imaging revealed a ruptured mass under the left diaphragm and fluid collection in the upper abdomen, flanks and pelvic cavity. Exploratory laparotomy confirmed the presence of an active bleeding tumor in the triangular ligament invading into the diaphragm. The tumor was resected with an appropriate diaphragm margin. The resected tumor was 5 cm in diameter and pathologically identified as hepatocellular carcinoma with a negative surgical margin. This case report shows that ruptured hepatocellular carcinoma should be considered in the differential diagnosis of non-traumatic hemoperitoneum. And it is necessary to set a surgical plan for unpredictable HCC rupture with direct diaphragm invasion.

  17. Design-based modeling of magnetically actuated soft diaphragm materials

    Science.gov (United States)

    Jayaneththi, V. R.; Aw, K. C.; McDaid, A. J.

    2018-04-01

    Magnetic polymer composites (MPC) have shown promise for emerging biomedical applications such as lab-on-a-chip and implantable drug delivery. These soft material actuators are capable of fast response, large deformation and wireless actuation. Existing MPC modeling approaches are computationally expensive and unsuitable for rapid design prototyping and real-time control applications. This paper proposes a macro-scale 1-DOF model capable of predicting force and displacement of an MPC diaphragm actuator. Model validation confirmed both blocked force and displacement can be accurately predicted in a variety of working conditions i.e. different magnetic field strengths, static/dynamic fields, and gap distances. The contribution of this work includes a comprehensive experimental investigation of a macro-scale diaphragm actuator; the derivation and validation of a new phenomenological model to describe MPC actuation; and insights into the proposed model’s design-based functionality i.e. scalability and generalizability in terms of magnetic filler concentration and diaphragm diameter. Due to the lumped element modeling approach, the proposed model can also be adapted to alternative actuator configurations, and thus presents a useful tool for design, control and simulation of novel MPC applications.

  18. Fungus infection in immunocompromised rabbits: correlation of thin-section CT findings and histopathology

    International Nuclear Information System (INIS)

    Xue Feng; Liu Shiyuan; Xie Lixuan; Liu Kai; Zhang Jian; Chen Yousan; Li Huimin; He Jin

    2009-01-01

    Objective: To compare the thin-section CT findings of pulmonary candidiasis, aspergillosis and cryptococcosis with histopathology in immunocompromised rabbits and improve the diagnostic accuracy of fungus infection. Methods: Healthy New Zealand white rabbits were used for immunocompromised animal models. Thin-section CT scan was performed before and 2, 4, 6, 8, 10, 12, 14 d after inoculation. The pattern and distribution of the pulmonary abnormalities were retrospectively assessed by two thoracic radiologists and compared with histopathology. The granulocyte count was compared before and after administration of immunosuppressive agents. The paired t test, chi square test and the Fisher's exact test were used for the statistics. Results: Fourteen rabbits had candidiasis, 16 rabbits had eryptococcosis, 15 rabbits had aspergillosis. The granulocyte counts before and after administration of immunosuppressive agents were (2.91±0.92) and (0.35±0.19) x 10 9 /L respectively in candidiasis group, there was a significant difference (t=12.484, P 9 /L in aspergillosis group, there was a significant difference (t=5.792, P 9 /L in cryptococcosis group, there was a significant difference (t=8.199, P 0.05). Ground glass opacity (GGO) and consolidation were the two most common findings in immunocompromised rabbits with three fungus infections, areas of GGO was correlated with the congestion, hemorrhage, inflammatory cell infiltration and interstitial hyperplasia in pathology. Consolidation was correlated with the severe congestion, hemorrhage, inflammatory cell infiltration, interstitial hyperplasia, necrosis and vascular embolism in pathology. Conclusion: GGO and consolidation are the two most common findings of fungus infections in immunocompromised animal models and thin-section CT findings can reflect the pathological changes. (authors)

  19. Fluid structure interaction in piston diaphragm pumps

    NARCIS (Netherlands)

    van Rijswick, R.J.A.

    2017-01-01

    Piston diaphragm pumps are used world-wide to transport abrasive and/or aggressive slurries against high discharge pressures in the mining, mineral processing and power industries. Limitation of excessive deformation of the diaphragm is of utmost importance for eliminating fatigue failures of the

  20. Diaphragm Effect of Steel Space Roof Systems in Hall Structures

    Directory of Open Access Journals (Sweden)

    Mehmet FENKLİ

    2015-09-01

    Full Text Available Hall structures have been used widely for different purposes. They have are reinforced concrete frames and shear wall with steel space roof systems. Earthquake response of hall structures is different from building type structures. One of the most critical nodes is diaphragm effect of steel space roof on earthquake response of hall structures. Diaphragm effect is depending on lateral stiffness capacity of steel space roof system. Lateral stiffness of steel space roof system is related to modulation geometry, support conditions, selected sections and system geometry. In current paper, three representative models which are commonly used in Turkey were taken in to account for investigation. Results of numerical tests were present comparatively

  1. Oxygen-enhanced MRI for patients with connective tissue diseases: Comparison with thin-section CT of capability for pulmonary functional and disease severity assessment

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Nishio, Mizuho [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Koyama, Hisanobu [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Yoshikawa, Takeshi; Matsumoto, Sumiaki [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Seki, Shinichiro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Tsubakimoto, Maho [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nakagami-Gun, Okinawa (Japan); Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan)

    2014-02-15

    Purpose: To prospectively and directly compare oxygen-enhanced (O{sub 2}-enhanced) MRI with thin-section CT for pulmonary functional loss and disease severity assessment in connective tissue disease (CTD) patients with interstitial lung disease (ILD). Materials and methods: Thin-section CT, O{sub 2}-enhanced MRI, pulmonary function test and serum KL-6 were administered to 36 CTD patients with ILD (23 men, 13 women; mean age: 63.9 years) and nine CTD patients without ILD (six men, and three women; mean age: 62.0 years). A relative-enhancement ratio (RER) map was generated from O{sub 2}-enhanced MRI and mean relative enhancement ratio (MRER) for each subject was calculated from all ROI measurements. CT-assessed disease severity was evaluated with a visual scoring system from each of the thin-section CT data. MRER and CT-assessed disease severities of CTD patients with and without ILD were then statistically compared. To assess capability for pulmonary functional loss and disease severity assessment in CTD patients, correlations of MRER and CT-assessed disease severity with pulmonary functional parameters and serum KL-6 in all subjects were statistically determined. Results: MRER and CT-assessed disease severity showed significant differences between CTD patients with (MRER: 0.15 ± 0.08, CT-assessed disease severity: 13.0 ± 7.4%) and without ILD (MRER: 0.25 ± 0.06, p = 0.0011; CT-assessed disease severity: 1.6 ± 1.6%, p < 0.0001). MRER and CT-assessed disease severity correlated significantly with pulmonary functional parameters and serum KL-6 in all subjects (0.61 ≤ r ≤ 0.79, p < 0.05). Conclusion: O{sub 2}-enhanced MRI was found to be as useful as thin-section CT for pulmonary functional loss and disease severity assessment of CTD patients with ILD.

  2. Oxygen-enhanced MRI for patients with connective tissue diseases: Comparison with thin-section CT of capability for pulmonary functional and disease severity assessment

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Seki, Shinichiro; Tsubakimoto, Maho; Sugimura, Kazuro

    2014-01-01

    Purpose: To prospectively and directly compare oxygen-enhanced (O 2 -enhanced) MRI with thin-section CT for pulmonary functional loss and disease severity assessment in connective tissue disease (CTD) patients with interstitial lung disease (ILD). Materials and methods: Thin-section CT, O 2 -enhanced MRI, pulmonary function test and serum KL-6 were administered to 36 CTD patients with ILD (23 men, 13 women; mean age: 63.9 years) and nine CTD patients without ILD (six men, and three women; mean age: 62.0 years). A relative-enhancement ratio (RER) map was generated from O 2 -enhanced MRI and mean relative enhancement ratio (MRER) for each subject was calculated from all ROI measurements. CT-assessed disease severity was evaluated with a visual scoring system from each of the thin-section CT data. MRER and CT-assessed disease severities of CTD patients with and without ILD were then statistically compared. To assess capability for pulmonary functional loss and disease severity assessment in CTD patients, correlations of MRER and CT-assessed disease severity with pulmonary functional parameters and serum KL-6 in all subjects were statistically determined. Results: MRER and CT-assessed disease severity showed significant differences between CTD patients with (MRER: 0.15 ± 0.08, CT-assessed disease severity: 13.0 ± 7.4%) and without ILD (MRER: 0.25 ± 0.06, p = 0.0011; CT-assessed disease severity: 1.6 ± 1.6%, p < 0.0001). MRER and CT-assessed disease severity correlated significantly with pulmonary functional parameters and serum KL-6 in all subjects (0.61 ≤ r ≤ 0.79, p < 0.05). Conclusion: O 2 -enhanced MRI was found to be as useful as thin-section CT for pulmonary functional loss and disease severity assessment of CTD patients with ILD

  3. Application of 2 mm thin-slice scanning with bone algorithm on conventional CT in diagnosis of the pulmonary diseases

    International Nuclear Information System (INIS)

    Zhang Xianheng; Li Xiuhua; Wang Fenghua

    2004-01-01

    Objective: To evaluate the value of 2 mm thin-slice conventional CT scan with bone algorithm in diagnosis and differential diagnosis in the pulmonary diseases. Methods: In total 135 cases of the pulmonary diseases were routinely scanned by conventional scan, 10 mm per slice, with standard algorithm, then the 2 mm thin-slice scan with bone algorithm was performed at the interested region of the lungs. Result: According to the comparative study of the CT signs between 10 mm slice scan with standard algorithm and 2 mm thin-slice scan with bone algorithm, the latter was better on displaying the pulmonary axial interstium, intralobular septum, subpleura lines, honeycombing, 2-5 mm nodulars and anomalies of bronchial wall. Conclusion: According to the study of 135 cases, 2 mm thin-slice scan with bone algorithm is superior to 10 mm slice scan with standard algorithm in demonstrating the pulmonary lesions. It has a similar value with high-resolution spiral CT in the diagnosis of the pulmonary solitary or diffuse nodules, pulmonary diffuse interstitial lesions and the lesions of the airway. It is practical and advisable in the community hospital

  4. Diaphragms obtained by radiochemical grafting in PTFE

    International Nuclear Information System (INIS)

    Nenner, T.; Fahrasmane, A.

    1984-01-01

    Diaphragms for alkaline water electrolysis are prepared by radiochemical grafting of PTFE fabric with styrene, which is later on sulfonated, or with acrylic acid. The diaphragms obtained are mechanically resistant to potash at temperatures up to 200 0 C, but show some degrafting, which limits the lifetime. The sulfonated styrene group has been found to be more stable in electrolysis than the acrylic acid. In both cases, the incorporation of a cross-linking agent like divinyl benzene improves the lifetime of the diaphragms. Electrolysis during 500 hours at 120 0 C and 10 kAm 2 could be performed. (author)

  5. CT of the pulmonary ligament

    International Nuclear Information System (INIS)

    Godwin, J.D.; Vock, P.; Osborne, D.R.

    1983-01-01

    Most computed tomographic (CT) scans of the chest show the inferior pulmonary ligament and an associated septum in the lower lobe, although CT descriptions of these structures have not been reported. Conventional radiography of the ligament has relied on indirect signs: the position of the lower lobe in the presence of pneumothorax or pleural effusion, soft-tissue peaks along the upper surface of the diaphragm, and the rare traumatic paramediastinal pneumatocele (attributed to air in the ligament). CT clarifies the anatomic relations of the ligament and alterations caused by pleural effusion and pneumothorax. The ligament is probably responsible for some long linear shadows at the lung bases, and CT helps to distinguish these from scars, walls of bullae, and normal structures such as the phrenic nerve and the interlobar fissures

  6. CT of the pulmonary ligament

    Energy Technology Data Exchange (ETDEWEB)

    Godwin, J.D.; Vock, P.; Osborne, D.R.

    1983-08-01

    Most computed tomographic (CT) scans of the chest show the inferior pulmonary ligament and an associated septum in the lower lobe, although CT descriptions of these structures have not been reported. Conventional radiography of the ligament has relied on indirect signs: the position of the lower lobe in the presence of pneumothorax or pleural effusion, soft-tissue peaks along the upper surface of the diaphragm, and the rare traumatic paramediastinal pneumatocele (attributed to air in the ligament). CT clarifies the anatomic relations of the ligament and alterations caused by pleural effusion and pneumothorax. The ligament is probably responsible for some long linear shadows at the lung bases, and CT helps to distinguish these from scars, walls of bullae, and normal structures such as the phrenic nerve and the interlobar fissures.

  7. Development of low-dose protocols for thin-section CT assessment of cystic fibrosis in pediatric patients.

    LENUS (Irish Health Repository)

    O'Connor, Owen J

    2010-12-01

    To develop low-dose thin-section computed tomographic (CT) protocols for assessment of cystic fibrosis (CF) in pediatric patients and determine the clinical usefulness thereof compared with chest radiography.

  8. Bending-Induced Giant Polarization in Ferroelectric MEMS Diaphragm

    KAUST Repository

    Wang, Zhihong

    2016-09-09

    The polarization induced by the strain gradient, i.e. the flexoelectric effect, has been observed in a micromachined Pb(Zr0.52Ti0.48)O3 (PZT) diaphragms. Applying air pressure to bend a flat diaphragm which initially does not exhibit any electromechanical coupling can induce a resonance peak in its impedance spectrum. This result supposes that bending, thus the strain gradient in the diaphragm causes polarization in PZT film. We also investigated the switching behaviors of the polarization in response to an external electric field in a bent diaphragm and further quantified the polarization induced by the strain gradient. The effective flexoelectric coefficient of the PZT film has been calculated as large as 2.0 × 10−4 C/m. A giant flexoelectric polarization of the order of 1 μC/cm2 was characterized which is of the same order of magnitude as the normal remnant ferroelectric polarization of PZT film. The suggested explanation for the giant polarization is the large strain gradient in the diaphragm and the strain gradient induced reorientation of the polar nanodomains.

  9. CT and MRI of the thorax

    International Nuclear Information System (INIS)

    Zerhouni, E.A.

    1990-01-01

    This book addresses a variety of topics in thoracic imaging, including magnetic resonance (MR) imaging in thoracic lymphoma; focal and high-resolution computed tomography (CT) of diffuse lung disease; imaging and disorders of the pleura, diaphragm, and mediastinum; and the increasingly important topic of the immunocompromised patient. Eight case studies close out the volume

  10. Fluid structure interaction in piston diaphragm pumps

    NARCIS (Netherlands)

    Van Rijswick, R.; Van Rhee, C.

    2013-01-01

    Piston diaphragm pumps are used world-wide for the transport of aggressive and/or abrasive fluids in the chemical, mining and mineral processing industries. Figure 1 shows a cross section of a piston diaphragm pump as is used in the mining and mineral processing industries for the transport of

  11. Radiofrequency ablation of pulmonary tumors near the diaphragm.

    Science.gov (United States)

    Iguchi, T; Hiraki, T; Gobara, H; Fujiwara, H; Sakurai, J; Matsui, Y; Mitsuhashi, T; Toyooka, S; Kanazawa, S

    To retrospectively evaluate the feasibility, safety, and efficacy of radiofrequency ablation (RFA) of lung tumors located near the diaphragm. A total of 26 patients (15 men, 11 women; mean age, 61.5 years±13.0 [SD]) with a total of 29 lung tumors near the diaphragm (i.e., distance<10mm) were included. Mean tumor diameter was 11.0mm±5.3 (SD) (range, 2-23mm). Efficacy of RFA, number of adverse events and number of adverse events with a grade≥3, based on the National Cancer Institute Common Terminology Criteria for Adverse Events, version 4.0, were compared between patients with lung tumors near the diaphragm and a control group of patients with more distally located lung tumors (i.e., distance≥10mm). RFA was technically feasible for all tumors near the diaphragm. Four grade 3 adverse events (1 pneumothorax requiring pleurodesis and 3 phrenic nerve injuries) were observed. No grade≥4 adverse events were reported. The median follow-up period for tumors near the diaphragm was 18.3 months. Local progression was observed 3.3 months after RFA in 1 tumor. The technique efficacy rates were 96.2% at 1 year and 96.2% at 2 years and were not different, from those observed in control subjects (186 tumors; P=0.839). Shoulder pain (P<0.001) and grade 1 pleural effusion (P<0.001) were more frequently observed in patients with lung tumor near the diaphragm. The rates of grade≥3 adverse events did not significantly differ between tumors near the diaphragm (4/26 sessions) and the controls (7/133 sessions) (P=0.083). RFA is a feasible and effective therapeutic option for lung tumors located near the diaphragm. However, it conveys a higher rate of shoulder pain and asymptomatic pleural effusion by comparison with more distant lung tumors. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  12. Displacement and resonance behaviors of a piezoelectric diaphragm driven by a double-sided spiral electrode

    KAUST Repository

    Shen, Zhiyuan

    2012-04-03

    This paper presents the design of a lead zirconate titanate (PZT) diaphragm actuated by double-sided patterned electrodes. Au/Cr electrodes were deposited on bulk PZT wafers by sputtering while patterned by a lift-off process. SU-8 thick film was used to form the structural layer. Double-spiral electrode induced in-plane poling and piezoelectric elongation are converted to an out-of-plane displacement due to the confined boundary condition. The influence of different drive configurations and electrode parameters on deflection has been calculated by finite element methods (FEM) using a uniform field model. Impedance and quasi-static displacement spectra of the diaphragm were measured after poling. Adouble-sided patterned electrode diaphragm can be actuated by more drive configurations than a single-sided one. Compared with a single-sided electrode drive, a double-sided out-of-phase drive configuration increases the coupling coefficient of the fundamental resonance from 7.6% to 11.8%. The displacement response of the diaphragm increases from 2.6 to 8.6nmV 1. Configurations including the electric field component perpendicular to the poling direction can stimulate shear modes of the diaphragm. © 2012 IOP Publishing Ltd.

  13. Design of a cam-form tool in precision reuse of a digital paper display

    International Nuclear Information System (INIS)

    Pa, Pai-Shan

    2010-01-01

    A reuse fabrication module that uses micro electroremoving as a precision machining process with a new design of the cam-form tool to remove defective indium-tin-oxide (ITO) thin film from the optical PET surfaces of a digital paper display is presented. A small diameter of the cathode of the cam-form tool corresponds to a higher removal rate for the ITO nanostructure. A small edge radius of the anode and a small gap width between the cathode and the ITO surface takes less time for the same amount of ITO removal. A higher feed rate of the optical PET diaphragm combines with enough electric power to drive fast micro-electroremoving. The high rotational speed of the cam-form tool can improve the effect of dreg discharge and is advantageous to associate with the fast feed rate of the optical PET diaphragm.

  14. The earliest history of diaphragm physiology.

    Science.gov (United States)

    Derenne, J P; Debru, A; Grassino, A E; Whitelaw, W A

    1994-12-01

    The diaphragm was recognized as a distinct anatomical structure in the earliest Greek writings. However, the precise description of wounds suffered by warriors during the Trojan war by Homer was not tied to any particular function. The diaphragm was assimilated to the region that harbours thought. The first physiologic explanations of respiration by Empedocles in the 5th century BC and the concepts introduced by Plato and Hippocrates did not include a significant participation of the diaphragm. Aristole was the first to link respiration to a particular organ and a specific movement of the thorax. However, he considered that it was the heart which caused the lungs to expand by heating them, and the lungs in turn forced the thorax to dilate, a concept which was to survive until the 17th century. As in Aristole's theory the diaphragm played no role in respiration and was just a fence separating the thorax from the abdomen. A major break through occurred in Alexandria in the 4th and 3rd century BC: Herophilus was the first to recognize that muscles were the agents of movement and Erasistratus performed animal experiments which showed that the respiratory muscles were the agents of respiratory movements, thus opening the way to the later discoveries of Galen.

  15. THE EFFECT OF INNER DIAPHRAGMS AND NON-CONTINUOUS SILL SECTION ON THE STIFFNESS OF AUTOMOTIVE B-PILLAR

    Directory of Open Access Journals (Sweden)

    C.F. Tan

    2017-11-01

    Full Text Available The paper discusses the knowledge on the behaviour of T-frame under specific loading will be obtained by experimental methods in order to investigate the deflection of the vehicle B-pillar or T-frame. In addition, a series of T-frame were designed with inner diaphragm at various location in the sill member in order to investigate the effect of inner diaphragm and noncontinuous closed hat section in the sill member. Lastly, the results from the experimental tests were compared with the finite element analysis results to demonstrate the effectiveness of the inner diaphragm in the automotive B-pillar.

  16. Mechanics of the canine diaphragm in pleural effusion.

    Science.gov (United States)

    De Troyer, André; Leduc, Dimitri; Cappello, Matteo; Gevenois, Pierre Alain

    2012-09-01

    Pleural effusion is a complicating feature of many diseases of the lung and pleura, but its effects on the mechanics of the diaphragm have not been assessed. In the present study, radiopaque markers were attached along muscle bundles in the midcostal region of the diaphragm in anesthetized dogs, and the three-dimensional location of the markers during relaxation before and after the stepwise introduction of liquid into the left or right pleural space and during phrenic nerve stimulation in the same conditions was determined using computed tomography. From these data, accurate measurements of diaphragm muscle length and displacement were obtained, and the changes in pleural and abdominal pressure were analyzed as functions of these parameters. The effect of liquid instillation on the axial position of rib 5 was also measured. The data showed that 1) liquid leaked through the dorsal mediastinal sheet behind the pericardium so that effusion was bilateral; 2) effusion caused a caudal displacement of the relaxed diaphragm; 3) this displacement was, compared with passive lung inflation, much larger than the cranial displacement of the ribs; and 4) the capacity of the diaphragm to generate pressure, in particular pleural pressure, decreased markedly as effusion increased, and this decrease was well explained by the decrease in active muscle length. It is concluded that pleural effusion has a major adverse effect on the pressure-generating capacity of the diaphragm and that this is the result of the action of hydrostatic forces on the muscle.

  17. Validation of ultrasonography for non-invasive assessment of diaphragm function in muscular dystrophy.

    Science.gov (United States)

    Whitehead, Nicholas P; Bible, Kenneth L; Kim, Min Jeong; Odom, Guy L; Adams, Marvin E; Froehner, Stanley C

    2016-12-15

    Duchenne muscular dystrophy (DMD) is a severe, degenerative muscle disease that is commonly studied using the mdx mouse. The mdx diaphragm muscle closely mimics the pathophysiological changes in DMD muscles. mdx diaphragm force is commonly assessed ex vivo, precluding time course studies. Here we used ultrasonography to evaluate time-dependent changes in diaphragm function in vivo, by measuring diaphragm movement amplitude. In mdx mice, diaphragm amplitude decreased with age and values were much lower than for wild-type mice. Importantly, diaphragm amplitude strongly correlated with ex vivo specific force values. Micro-dystrophin administration increased mdx diaphragm amplitude by 26% after 4 weeks. Diaphragm amplitude correlated positively with ex vivo force values and negatively with diaphragm fibrosis, a major cause of DMD muscle weakness. These studies validate diaphragm ultrasonography as a reliable technique for assessing time-dependent changes in mdx diaphragm function in vivo. This technique will be valuable for testing potential therapies for DMD. Duchenne muscular dystrophy (DMD) is a severe, degenerative muscle disease caused by dystrophin mutations. The mdx mouse is a widely used animal model of DMD. The mdx diaphragm muscle most closely recapitulates key features of DMD muscles, including progressive fibrosis and considerable force loss. Diaphragm function in mdx mice is commonly evaluated by specific force measurements ex vivo. While useful, this method only measures force from a small muscle sample at one time point. Therefore, accurate assessment of diaphragm function in vivo would provide an important advance to study the time course of functional decline and treatment benefits. Here, we evaluated an ultrasonography technique for measuring time-dependent changes of diaphragm function in mdx mice. Diaphragm movement amplitude values for mdx mice were considerably lower than those for wild-type, decreased from 8 to 18 months of age, and correlated

  18. Pulmonary langerhans cell histiocytosis in adults: high-resolution CT - pathology comparisons and evolutional changes at CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Jin; Lee, Ho Yun; Kim, Tae Sung [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Samsung Medical Center, Department of Radiology, Seoul (Korea, Republic of); Johkoh, Takeshi [Kinki Central Hospital of Mutual Aid Association of Public School Teachers, Department of Radiology, Hyoko (Japan); Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Osaka (Japan); Han, Joungho [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of)

    2011-07-15

    To compare high-resolution (HR) CT and histopathological findings and to evaluate serial CT findings in pulmonary Langerhans cell histiocytosis (PLCH). We reviewed CT of lung lesions in 27 adults (M:F = 20:7, mean age, 41 {+-} 12.3 years) with PLCH. After evaluating lung abnormalities including nodules, micronodules, thick-walled, thin-walled, and bizarre-shaped cysts and reticulation, observers compared CT findings obtained at lung biopsy sites with histopathological findings. The final CT was compared with the initial CT to determine disease extent changes. The most frequently observed patterns of lung abnormalities were micronodules (n = 24, 89%), thick-walled (n = 22, 82%), and thin-walled (n = 22, 82%) cysts. Even thin-walled and bizarre cysts harboured active inflammatory Langerhans cell sheets and eosinophils in their walls. In thin-walled cysts, we noted pericystic inflammatory cell infiltrations along the alveolar walls, as well as pericystic emphysema. Thin-walled or bizarre cysts demonstrated a tendency to coalesce with surrounding cysts via their cystic wall destruction. Fourteen (52%) patients showed improvement and nine (33%) showed progressing disease. More than half of patients with pulmonary PLCH show improvement at follow-up CT. Even thin-walled cysts harbour active inflammatory cells on histopathology and exhibit improvement at follow-up CT. (orig.)

  19. Hyperglycemia-induced diaphragm weakness is mediated by oxidative stress

    Science.gov (United States)

    2014-01-01

    Introduction A major consequence of ICU-acquired weakness (ICUAW) is diaphragm weakness, which prolongs the duration of mechanical ventilation. Hyperglycemia (HG) is a risk factor for ICUAW. However, the mechanisms underlying HG-induced respiratory muscle weakness are not known. Excessive reactive oxygen species (ROS) injure multiple tissues during HG, but only one study suggests that excessive ROS generation may be linked to HG-induced diaphragm weakness. We hypothesized that HG-induced diaphragm dysfunction is mediated by excessive superoxide generation and that administration of a specific superoxide scavenger, polyethylene glycol superoxide dismutase (PEG-SOD), would ameliorate these effects. Methods HG was induced in rats using streptozotocin (60 mg/kg intravenously) and the following groups assessed at two weeks: controls, HG, HG + PEG-SOD (2,000U/kg/d intraperitoneally for seven days), and HG + denatured (dn)PEG-SOD (2000U/kg/d intraperitoneally for seven days). PEG-SOD and dnPEG-SOD were administered on day 8, we measured diaphragm specific force generation in muscle strips, force-pCa relationships in single permeabilized fibers, contractile protein content and indices of oxidative stress. Results HG reduced diaphragm specific force generation, altered single fiber force-pCa relationships, depleted troponin T, and increased oxidative stress. PEG-SOD prevented HG-induced reductions in diaphragm specific force generation (for example 80 Hz force was 26.4 ± 0.9, 15.4 ± 0.9, 24.0 ± 1.5 and 14.9 ± 0.9 N/cm2 for control, HG, HG + PEG-SOD, and HG + dnPEG-SOD groups, respectively, P hyperglycemia-induced diaphragm dysfunction. This new mechanistic information could explain how HG alters diaphragm function during critical illness. PMID:24886999

  20. Localized thin-section CT with radiomics feature extraction and machine learning to classify early-detected pulmonary nodules from lung cancer screening

    Science.gov (United States)

    Tu, Shu-Ju; Wang, Chih-Wei; Pan, Kuang-Tse; Wu, Yi-Cheng; Wu, Chen-Te

    2018-03-01

    Lung cancer screening aims to detect small pulmonary nodules and decrease the mortality rate of those affected. However, studies from large-scale clinical trials of lung cancer screening have shown that the false-positive rate is high and positive predictive value is low. To address these problems, a technical approach is greatly needed for accurate malignancy differentiation among these early-detected nodules. We studied the clinical feasibility of an additional protocol of localized thin-section CT for further assessment on recalled patients from lung cancer screening tests. Our approach of localized thin-section CT was integrated with radiomics features extraction and machine learning classification which was supervised by pathological diagnosis. Localized thin-section CT images of 122 nodules were retrospectively reviewed and 374 radiomics features were extracted. In this study, 48 nodules were benign and 74 malignant. There were nine patients with multiple nodules and four with synchronous multiple malignant nodules. Different machine learning classifiers with a stratified ten-fold cross-validation were used and repeated 100 times to evaluate classification accuracy. Of the image features extracted from the thin-section CT images, 238 (64%) were useful in differentiating between benign and malignant nodules. These useful features include CT density (p  =  0.002 518), sigma (p  =  0.002 781), uniformity (p  =  0.032 41), and entropy (p  =  0.006 685). The highest classification accuracy was 79% by the logistic classifier. The performance metrics of this logistic classification model was 0.80 for the positive predictive value, 0.36 for the false-positive rate, and 0.80 for the area under the receiver operating characteristic curve. Our approach of direct risk classification supervised by the pathological diagnosis with localized thin-section CT and radiomics feature extraction may support clinical physicians in determining

  1. Bending-induced electromechanical coupling and large piezoelectric response in a micromachined diaphragm

    KAUST Repository

    Wang, Zhihong

    2013-11-04

    We investigated the dependence of electromechanical coupling and the piezoelectric response of a micromachined Pb(Zr 0.52 Ti 0.48)O 3 (PZT) diaphragm on its curvature by observing the impedance spectrum and central deflection responses to a small AC voltage. The curvature of the diaphragm was controlled by applying air pressure to its back. We found that a depolarized flat diaphragm does not initially exhibit electromechanical coupling or the piezoelectric response. However, upon the application of static air pressure to the diaphragm, both electromechanical coupling and the piezoelectric response can be induced in the originally depolarized diaphragm. The piezoelectric response increases as the curvature increases and a giant piezoelectric response can be obtained from a bent diaphragm. The obtained results clearly demonstrate that a high strain gradient in a diaphragm can polarize a PZT film through a flexoelectric effect, and that the induced piezoelectric response of the diaphragm can be controlled by adjusting its curvature.

  2. Fatty liver: prospective comparative study with sonography and CT

    International Nuclear Information System (INIS)

    Kim, Sung Jin; Kim, Y. M.; Kim, W. S.; Choi, B. I.; Lee, J. S.; Han, C. K.; Kim, C. W.

    1990-01-01

    To identify the reasonable criteria in detection of the degree of Fatty liver, we prospectively evaluated sonograms and CT scans in 33 Patients With bright liver on sonography. On sonograms, we analyzed the echogenicity of the liver, acoustic attenuation, and visualization of the portal vein and the diaphragm, Each criterion was scored from 0 to 2. CT criterion for fatty liver was assessed by the attenuation difference between the liver and the spleen on nonocontrast CT scans, The average sonographic grade for CT Grade I was 1.3, Grade II was 2.1,and Grade III was 2.8. The accurate detection rate of each sonographic grade was as follows, Grade

  3. Inhalation of Budesonide/Formoterol Increases Diaphragm Muscle Contractility

    Directory of Open Access Journals (Sweden)

    Chiyohiko Shindoh

    2012-01-01

    Conclusions: BUD/FORM inhalation has an inotropic effect on diaphragm muscle, protects diaphragm muscle deterioration after endotoxin injection, and inhibits NO production. Increments in muscle contractility with BUD/FORM inhalation are induced through a synergistic effect of an anti-inflammatory agent and 02-agonist.

  4. Detecting defects in diaphragm walls prior to excavation

    NARCIS (Netherlands)

    Spruit, R.; Hopman, V.; Van Tol, A.F.; Broere, W.

    2011-01-01

    Recent incidents with leaking diaphragm walls during construction of subway lines in Amsterdam and Rotterdam (Netherlands) have led to reconsideration of the diaphragm wall as a retaining wall construction for deep excavations. In our opinion the joints between the panels are the weak spot. During

  5. ORIGINAL ARTICLE ORIG ORIG CT for upper abdominal pathology ...

    African Journals Online (AJOL)

    ORIG. 14. SA JOURNAL OF RADIOLOGY • March 2007. ORIG. Abstract. Background. Current practice at our institution for routine abdominal. CT includes coverage from the diaphragm to the symphysis pubis and therefore includes pelvic organs. Limited upper abdominal imaging exists in other modalities, and tailoring the ...

  6. Applying microCT and 3D visualization to Jurassic silicified conifer seed cones: A virtual advantage over thin-sectioning.

    Science.gov (United States)

    Gee, Carole T

    2013-11-01

    As an alternative to conventional thin-sectioning, which destroys fossil material, high-resolution X-ray computed tomography (also called microtomography or microCT) integrated with scientific visualization, three-dimensional (3D) image segmentation, size analysis, and computer animation is explored as a nondestructive method of imaging the internal anatomy of 150-million-year-old conifer seed cones from the Late Jurassic Morrison Formation, USA, and of recent and other fossil cones. • MicroCT was carried out on cones using a General Electric phoenix v|tome|x s 240D, and resulting projections were processed with visualization software to produce image stacks of serial single sections for two-dimensional (2D) visualization, 3D segmented reconstructions with targeted structures in color, and computer animations. • If preserved in differing densities, microCT produced images of internal fossil tissues that showed important characters such as seed phyllotaxy or number of seeds per cone scale. Color segmentation of deeply embedded seeds highlighted the arrangement of seeds in spirals. MicroCT of recent cones was even more effective. • This is the first paper on microCT integrated with 3D segmentation and computer animation applied to silicified seed cones, which resulted in excellent 2D serial sections and segmented 3D reconstructions, revealing features requisite to cone identification and understanding of strobilus construction.

  7. Evaluation of phrenic nerve and diaphragm function with peripheral nerve stimulation and M-mode ultrasonography in potential pediatric phrenic nerve or diaphragm pacing candidates.

    Science.gov (United States)

    Skalsky, Andrew J; Lesser, Daniel J; McDonald, Craig M

    2015-02-01

    Assessing phrenic nerve function in the setting of diaphragmatic paralysis in diaphragm pacing candidates can be challenging. Traditional imaging modalities and electrodiagnostic evaluations are technically difficult. Either modality alone is not a direct measure of the function of the phrenic nerve and diaphragm unit. In this article, the authors present their method for evaluating phrenic nerve function and the resulting diaphragm function. Stimulating the phrenic nerve with transcutaneous stimulation and directly observing the resulting movement of the hemidiaphragm with M-mode ultrasonography provides quantitative data for predicting the success of advancing technologies such as phrenic nerve pacing and diaphragm pacing. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Improved attenuation correction for respiratory gated PET/CT with extended-duration cine CT: a simulation study

    Science.gov (United States)

    Zhang, Ruoqiao; Alessio, Adam M.; Pierce, Larry A.; Byrd, Darrin W.; Lee, Tzu-Cheng; De Man, Bruno; Kinahan, Paul E.

    2017-03-01

    Due to the wide variability of intra-patient respiratory motion patterns, traditional short-duration cine CT used in respiratory gated PET/CT may be insufficient to match the PET scan data, resulting in suboptimal attenuation correction that eventually compromises the PET quantitative accuracy. Thus, extending the duration of cine CT can be beneficial to address this data mismatch issue. In this work, we propose to use a long-duration cine CT for respiratory gated PET/CT, whose cine acquisition time is ten times longer than a traditional short-duration cine CT. We compare the proposed long-duration cine CT with the traditional short-duration cine CT through numerous phantom simulations with 11 respiratory traces measured during patient PET/CT scans. Experimental results show that, the long-duration cine CT reduces the motion mismatch between PET and CT by 41% and improves the overall reconstruction accuracy by 42% on average, as compared to the traditional short-duration cine CT. The long-duration cine CT also reduces artifacts in PET images caused by misalignment and mismatch between adjacent slices in phase-gated CT images. The improvement in motion matching between PET and CT by extending the cine duration depends on the patient, with potentially greater benefits for patients with irregular breathing patterns or larger diaphragm movements.

  9. Subacute presentation of spontaneous diaphragmal rupture: case report

    Directory of Open Access Journals (Sweden)

    Dejan Hermann

    2005-07-01

    Full Text Available Background: Diaphragmatic injuries are relatively rare and present with non specific symptoms and signs. Late discoveries are almost a rule in all but the most evident cases. Many patients are observed or even treated for suspected other conditions, most often musculosceletal disorders.Patients and methods: We report a case of a 14-year-old boy who presented with left lumbar pain and developed peritonitis six days after strenuous training. A chest X-ray revealed abdominal viscera in the left hemithorax. A large posterolateral rupture of the left diaphragm was found at laparotomy together with herniation of the stomach, spleen and colon. The stomach was perforated and partialy necrotic. Afer partial gastrectomy, repositioning and diaphragmal repair the patient recovered well.Conclusions: If pain in toracoabdominal region is a predominant sign after trauma or endogenous strain, one should consider the posibility of ruptured diaphragm and make a chest X-ray. Operation of diaphragmal hernia is necessary and garanties good results when treated on time.

  10. Determination of ventilatory liver movement via radiographic evaluation of diaphragm position

    International Nuclear Information System (INIS)

    Balter, James M.; Dawson, Laura A.; Kazanjian, Sahira; McGinn, Cornelius; Brock, Kristy K.; Lawrence, Theodore; Haken, Randall ten

    2001-01-01

    Purpose: To determine the accuracy of estimation of liver movement inferred by observing diaphragm excursion on radiographic images. Methods and Materials: Eight patients with focal liver cancer had platinum embolization microcoils implanted in their livers during catheterization of the hepatic artery for delivery of regional chemotherapy. These patients underwent fluoroscopy, during which normal breathing movement was recorded on videotape. Movies of breathing movement were digitized, and the relative projected positions of the diaphragm and coils were recorded. For 6 patients, daily radiographs were also acquired during treatment. Retrospective measurements of coil position were taken after the diaphragm was aligned with the superior portion of the liver on digitally reconstructed radiographs. Results: Coil movement of 4.9 to 30.4 mm was observed during normal breathing. Diaphragm position tracked inferior-superior coil displacement accurately (population σ 1.04 mm) throughout the breathing cycle. The range of coil movement was predicted by the range of diaphragm movement with an accuracy of 2.09 mm (σ). The maximum error observed measuring coil movement using diaphragm position was 3.8 mm for a coil 9.8 cm inferior to the diaphragm. However, the distance of the coil from the top of the diaphragm did not correlate significantly with the error in predicting liver excursion. Analysis of daily radiographs showed that the error in predicting coil position using the diaphragm as an alignment landmark was 1.8 mm (σ) in the inferior-superior direction and 2.2 mm in the left-right direction, similar in magnitude to the inherent uncertainty in alignment. Conclusions: This study demonstrated that the range of ventilatory movement of different locations within the liver is predicted by diaphragm position to an accuracy that matches or exceeds existing systems for ventilatory tracking. This suggests that the diaphragm is an acceptable anatomic landmark for radiographic

  11. GND-PCA-based statistical modeling of diaphragm motion extracted from 4D MRI.

    Science.gov (United States)

    Swastika, Windra; Masuda, Yoshitada; Xu, Rui; Kido, Shoji; Chen, Yen-Wei; Haneishi, Hideaki

    2013-01-01

    We analyzed a statistical model of diaphragm motion using regular principal component analysis (PCA) and generalized N-dimensional PCA (GND-PCA). First, we generate 4D MRI of respiratory motion from 2D MRI using an intersection profile method. We then extract semiautomatically the diaphragm boundary from the 4D-MRI to get subject-specific diaphragm motion. In order to build a general statistical model of diaphragm motion, we normalize the diaphragm motion in time and spatial domains and evaluate the diaphragm motion model of 10 healthy subjects by applying regular PCA and GND-PCA. We also validate the results using the leave-one-out method. The results show that the first three principal components of regular PCA contain more than 98% of the total variation of diaphragm motion. However, validation using leave-one-out method gives up to 5.0 mm mean of error for right diaphragm motion and 3.8 mm mean of error for left diaphragm motion. Model analysis using GND-PCA provides about 1 mm margin of error and is able to reconstruct the diaphragm model by fewer samples.

  12. Free Piston Double Diaphragm Shock Tube

    OpenAIRE

    OGURA, Eiji; FUNABIKI, Katsushi; SATO, Shunichi; ABE, Takashi; 小倉, 栄二; 船曳, 勝之; 佐藤, 俊逸; 安部, 隆士

    1997-01-01

    A free piston double diaphragm shock tube was newly developed for generation of high Mach number shock wave. Its characteristics was investigated for various operation parameters; such as a strength of the diaphragm at the end of the comparession tube, an initial pressure of low pressure tube, an initial pressure of medium pressure tube and the volume of compression tube. Under the restriction of fixed pressures for the driver high pressure tube (32×10^5Pa) and the low pressure tube (40Pa) in...

  13. Diaphragm walling for Sizewell B sets records

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    The first phase of construction of the Sizewell-B nuclear reactor has been completed. This was the building of a diaphragm wall around the site. It is one of the largest and deepest diaphragm walls to be installed in Europe. The site can be pumped dry of groundwater and the foundations constructed in the dry. The specifications of the wall and its construction, using two Hydrofraise excavation rigs, are described. The excavated material is brought up as a slurry and the (bentonite) slurry is cleaned and desanded. Most of the wall has been formed using a plastic concrete but reinforced concrete has been used for some stretches. The diaphragm wall, which is 1258m long and 55m deep on average, was built in 19 weeks. (U.K.)

  14. Giant flexoelectric polarization in a micromachined ferroelectric diaphragm

    KAUST Repository

    Wang, Zhihong

    2012-08-14

    The coupling between dielectric polarization and strain gradient, known as flexoelectricity, becomes significantly large on the micro- and nanoscale. Here, it is shown that giant flexoelectric polarization can reverse remnant ferroelectric polarization in a bent Pb(Zr0.52Ti0.48) O3 (PZT) diaphragm fabricated by micromachining. The polarization induced by the strain gradient and the switching behaviors of the polarization in response to an external electric field are investigated by observing the electromechanical coupling of the diaphragm. The method allows determination of the absolute zero polarization state in a PZT film, which is impossible using other existing methods. Based on the observation of the absolute zero polarization state and the assumption that bending of the diaphragm is the only source of the self-polarization, the upper bound of flexoelectric coefficient of PZT film is calculated to be as large as 2.0 × 10-4 C m -1. The strain gradient induced by bending the diaphragm is measured to be on the order of 102 m-1, three orders of magnitude larger than that obtained in the bulk material. Because of this large strain gradient, the estimated giant flexoelectric polarization in the bent diaphragm is on the same order of magnitude as the normal remnant ferroelectric polarization of PZT film. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Influence of double-diaphragm vacuum compaction on deformation during forming of composite prepregs

    Directory of Open Access Journals (Sweden)

    Hassan Alshahrani

    2016-12-01

    Full Text Available During the diaphragm forming process, a vacuum seal is applied between the upper and lower diaphragms to compact and hold the laminate. Therefore, a thorough characterization of the in-plane shear behavior of fabrics under diaphragm forming conditions must take into account the effect of vacuum-sealing and compaction between the two diaphragms during bias extension. The study presented here examined the shear angles of out-of-autoclave 8-harness satin woven carbon/epoxy prepregs under diaphragm compaction. A bias extension test was conducted to study the effect of diaphragm compaction and ply interactions on shear properties. The test was performed at different compaction levels, and changes in shear angle with respect to vacuum levels and diaphragm compaction forces were observed. The contribution of diaphragm material and ply interaction to shear stiffness was evaluated and compared with results from a direct bias extension test. The samples were tested at both room temperature and at elevated temperatures using a radiant heater. The results show that shear angle decreases significantly as vacuum pressure and compaction is applied between the two diaphragms. This finding indicates that vacuum levels and compaction forces have a significant influence on the deformation limit and wrinkling onset during the diaphragm forming process.

  16. A novel technique for diaphragm biopsies in human patients.

    Science.gov (United States)

    Noullet, Séverine; Romero, Norma; Menegaux, Fabrice; Chapart, Maud; Demoule, Alexandre; Morelot-Panzini, Capucine; Similowski, Thomas; Gonzalez-Bermejo, Jésus

    2015-06-15

    The diaphragm is difficult to biopsy because of its anatomic location. We describe a new laparoscopic diaphragm biopsy technique. Fifty one patients with amyotrophic lateral sclerosis gave their consent to diaphragm biopsy in the context of an implanted phrenic nerve stimulation protocol (NCT01583088). The biopsy was taken from the costal diaphragm, after opening the parietal peritoneum with scissors, and by grasping the diaphragmatic muscle over the rib with toothed laparoscopy forceps. The first four electrocoagulation biopsies were unsuitable for morphologic examination. The following 47 biopsies were therefore performed without electrocoagulation. The mean size of the biopsy fragments obtained after preparation was 3 ± 1 × 2 ± 1 × 1 ± 1 mm (maximum: 4 × 3 × 2 mm). A diaphragmatic injury occurred during the section in three cases requiring immediate suture without causing pneumothorax. A small pleural effusion was observed on the postoperative chest x-ray in one patient with a spontaneously favorable outcome. Numerous stains were able to be performed on the fragments obtained. Diaphragm biopsy can be safely performed by laparoscopy and yields tissue suitable for our future histologic evaluation. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Emergency department CT screening of patients with nontraumatic neurological symptoms referred to the posterior fossa: comparison of thin versus thick slice images.

    Science.gov (United States)

    Kamalian, Shervin; Atkinson, Wendy L; Florin, Lauren A; Pomerantz, Stuart R; Lev, Michael H; Romero, Javier M

    2014-06-01

    Evaluation of the posterior fossa (PF) on 5-mm-thick helical CT images (current default) has improved diagnostic accuracy compared to 5-mm sequential CT images; however, 5-mm-thick images may not be ideal for PF pathology due to volume averaging of rapid changes in anatomy in the Z-direction. Therefore, we sought to determine if routine review of 1.25-mm-thin helical CT images has superior accuracy in screening for nontraumatic PF pathology. MRI proof of diagnosis was obtained within 6 h of helical CT acquisition for 90 consecutive ED patients with, and 88 without, posterior fossa lesions. Helical CT images were post-processed at 1.25 and 5-mm-axial slice thickness. Two neuroradiologists blinded to the clinical/MRI findings reviewed both image sets. Interobserver agreement and accuracy were rated using Kappa statistics and ROC analysis, respectively. Of the 90/178 (51 %) who were MR positive, 60/90 (66 %) had stroke and 30/90 (33 %) had other etiologies. There was excellent interobserver agreement (κ > 0.97) for both thick and thin slice assessments. The accuracy, sensitivity, and specificity for 1.25-mm images were 65, 44, and 84 %, respectively, and for 5-mm images were 67, 45, and 85 %, respectively. The diagnostic accuracy was not significantly different (p > 0.5). In this cohort of patients with nontraumatic neurological symptoms referred to the posterior fossa, 1.25-mm-thin slice CT reformatted images do not have superior accuracy compared to 5-mm-thick images. This information has implications on optimizing resource utilizations and efficiency in a busy emergency room. Review of 1.25-mm-thin images may help diagnostic accuracy only when review of 5-mm-thick images as current default is inconclusive.

  18. A Study of Free-Piston Double-Diaphragm Drivers for Expansion Tubes. Report 1

    Science.gov (United States)

    Kendall, M. A.

    1997-01-01

    In recent years the free-piston double-diaphragm driver has been used to increase the performance of the XI pilot expansion tube to super-orbital test conditions. However, the actual performance of the double-diaphragm driver was found to be considerably less than ideal. An experimental study of the double-diaphragm driver was carried out on the XI facility over a range of conditions with the objective of determining the effect of. heat losses; and the non-ideal rupture of the 'light' secondary diaphragm on the driver performance. The disparity between the theoretical and measured performance envelope are highlighted. A viscous limit for the experiments vas established. Heat transfer behind the primary shock is shown to be the mechanism behind this limit Incident, reflected and transmitted shock trajectories for the secondary diaphragm were experimentally determined and compared with computed trajectories from a one-dimensional diaphragm inertia model. It was found that the diaphragm did influence the unsteady expansion. A good agreement between experimental and computed shock trajectories was obtained using a diaphragm inertia model assuming that the diaphragm mass became negligible 3 microns after shock impact.

  19. Applying microCT and 3D visualization to Jurassic silicified conifer seed cones: A virtual advantage over thin-sectioning1

    Science.gov (United States)

    Gee, Carole T.

    2013-01-01

    • Premise of the study: As an alternative to conventional thin-sectioning, which destroys fossil material, high-resolution X-ray computed tomography (also called microtomography or microCT) integrated with scientific visualization, three-dimensional (3D) image segmentation, size analysis, and computer animation is explored as a nondestructive method of imaging the internal anatomy of 150-million-year-old conifer seed cones from the Late Jurassic Morrison Formation, USA, and of recent and other fossil cones. • Methods: MicroCT was carried out on cones using a General Electric phoenix v|tome|x s 240D, and resulting projections were processed with visualization software to produce image stacks of serial single sections for two-dimensional (2D) visualization, 3D segmented reconstructions with targeted structures in color, and computer animations. • Results: If preserved in differing densities, microCT produced images of internal fossil tissues that showed important characters such as seed phyllotaxy or number of seeds per cone scale. Color segmentation of deeply embedded seeds highlighted the arrangement of seeds in spirals. MicroCT of recent cones was even more effective. • Conclusions: This is the first paper on microCT integrated with 3D segmentation and computer animation applied to silicified seed cones, which resulted in excellent 2D serial sections and segmented 3D reconstructions, revealing features requisite to cone identification and understanding of strobilus construction. PMID:25202495

  20. Hypoxia-induced dysfunction of rat diaphragm: role of peroxynitrite.

    NARCIS (Netherlands)

    Zhu, X.; Heunks, L.M.A.; Versteeg, E.M.M.; Heijden, E. van der; Ennen, L.; Kuppevelt, A.H.M.S.M. van; Vina, J.; Dekhuijzen, P.N.R.

    2005-01-01

    Oxidants may play a role in hypoxia-induced respiratory muscle dysfunction. In the present study we hypothesized that hypoxia-induced impairment in diaphragm contractility is associated with elevated peroxynitrite generation. In addition, we hypothesized that strenuous contractility of the diaphragm

  1. The thin-section CT, pathological and clinical findings of peripheral small squamous cell lung carcinomas

    International Nuclear Information System (INIS)

    Yamamoto, Takahito; Saito, Haruhiro; Kondo, Tetsuro

    2010-01-01

    We analyzed thin-section CT, pathological, and clinical findings of peripheral lung squamous cell carcinomas, with diameters of less than 20 mm and compared these findings with solid type adenocarcinomas. CT findings of polygonal shapes, notches, pleural thickness, and cavities are more frequently found in squamous cell carcinomas than in adenocarcinomas. The pathological types can be classified in two groups: Solid types, Scirrhous types. The 5 year survival rate after resection is 64.5%, which is poorer than survival rate for solid type adenocarcinomas. It is vital to diagnose and treat peripheral squamous cell carcinomas as early as possible. (author)

  2. Idiopathic diaphragmatic paralysis: Bell's palsy of the diaphragm?

    Science.gov (United States)

    Crausman, Robert S; Summerhill, Eleanor M; McCool, F Dennis

    2009-01-01

    Idiopathic diaphragm paralysis is probably more common and responsible for more morbidity than generally appreciated. Bell's palsy, or idiopathic paralysis of the seventh cranial nerve, may be seen as an analogous condition. The roles of zoster sine herpete and herpes simplex have increasingly been recognized in Bell's palsy, and there are some data to suggest that antiviral therapy is a useful adjunct to steroid therapy. Thus, we postulated that antiviral therapy might have a positive impact on the course of acute idiopathic diaphragm paralysis which is likely related to viral infection. Three consecutive patients with subacute onset of symptomatic idiopathic hemidiaphragm paralysis were empirically treated with valacyclovir, 1,000 mg twice daily for 1 week. Prior to therapy, diaphragmatic function was assessed via pulmonary function testing and two-dimensional B-mode ultrasound, with testing repeated 1 month later. Diaphragmatic function pre- and post-treatment was compared to that of a historical control group of 16 untreated patients. All three subjects demonstrated ultrasound recovery of diaphragm function 4-6 weeks following treatment with valacyclovir. This recovery was accompanied by improvements in maximum inspiratory pressure (PI(max)) and vital capacity (VC). In contrast, in the untreated cohort, diaphragm recovery occurred in only 11 subjects, taking an average of 14.9 +/- 6.1 months (mean +/- SD). The results of this small, preliminary study suggest that antiviral therapy with valacyclovir may be helpful in the treatment of idiopathic diaphragm paralysis induced by a viral infection.

  3. Monte Carlo analysis of thermal transpiration effects in capacitance diaphragm gauges with helicoidal baffle system

    International Nuclear Information System (INIS)

    Vargas, M; Stefanov, S; Wüest, M

    2012-01-01

    The Capacitance Diaphragm Gauge (CDG) is one of the most widely used vacuum gauges in low and middle vacuum ranges. This device consists basically of a very thin ceramic or metal diaphragm which forms one of the electrodes of a cap acitor. The pressure is determined by measuring the variation in the capacitance due to the deflection of the diaphragm caused by the pressure difference established across the membrane. In order to minimize zero drift, some CDGs are operated keeping the sensor at a higher temperature. This difference in the temperature between the sensor and the vacuum chamber makes the behaviour of the gauge non-linear due to thermal transpiration effects. This effect becomes more significant when we move from the transitional flow to the free molecular regime. Besides, CDGs may incorporate different baffle systems to avoid the condensation on the membrane or its contamination. In this work, the thermal transpiration effect on the behaviour of a rarefied gas and on the measurements in a CDG with a helicoidal baffle system is investigated by using the Direct Simulation Monte Carlo method (DSMC). The study covers the behaviour of the system under the whole range of rarefaction, from the continuum up to the free molecular limit and the results are compared with empirical results. Moreover, the influence of the boundary conditions on the thermal transpiration effects is investigated by using Maxwell boundary conditions.

  4. Treating traumatic injuries of the diaphragm

    Directory of Open Access Journals (Sweden)

    Dwivedi Sankalp

    2010-01-01

    Full Text Available Traumatic diaphragmatic injury (DI is a unique clinical entity that is usually occult and can easily be missed. Their delayed presentation can be due to the delayed rupture of the diaphragm or delayed detection of diaphragmatic rupture, making the accurate diagnosis of DI challenging to the trauma surgeons. An emergency laparotomy and thorough exploration followed by the repair of the defect is the gold standard for the management of these cases. We report a case of blunt DI in an elderly gentleman and present a comprehensive overview for the management of traumatic injuries of the diaphragm.

  5. Rectal diaphragm in a patient with imperforate anus and rectoprostatic fistula

    Directory of Open Access Journals (Sweden)

    Thakur Ashokanand

    2009-01-01

    Full Text Available The association of rectal diaphragm in an imperforate anus has not been reported until now. A 1-year-old male presented with right transverse colostomy for high anorectal malformation. The patient had imperforate anus and a recto-prostatic fistula with rectal diaphragm. We managed the case by an ano-rectal pull through with excision of the diaphragm.

  6. Diaphragm pacing improves sleep in patients with amyotrophic lateral sclerosis.

    Science.gov (United States)

    Gonzalez-Bermejo, Jesus; Morélot-Panzini, Capucine; Salachas, François; Redolfi, Stefania; Straus, Christian; Becquemin, Marie-Hélène; Arnulf, Isabelle; Pradat, Pierre-François; Bruneteau, Gaëlle; Ignagni, Anthony R; Diop, Moustapha; Onders, Raymond; Nelson, Teresa; Menegaux, Fabrice; Meininger, Vincent; Similowski, Thomas

    2012-01-01

    In amyotrophic lateral sclerosis (ALS) patients, respiratory insufficiency is a major burden. Diaphragm conditioning by electrical stimulation could interfere with lung function decline by promoting the development of type 1 muscle fibres. We describe an ancillary study to a prospective, non-randomized trial (NCT00420719) assessing the effects of diaphragm pacing on forced vital capacity (FVC). Sleep-related disturbances being early clues to diaphragmatic dysfunction, we postulated that they would provide a sensitive marker. Stimulators were implanted laparoscopically in the diaphragm close to the phrenic motor point in 18 ALS patients for daily conditioning. ALS functioning score (ALSFRS), FVC, sniff nasal inspiratory pressure (SNIP), and polysomnographic recordings (PSG, performed with the stimulator turned off) were assessed before implantation and after four months of conditioning (n = 14). Sleep efficiency improved (69 ± 15% to 75 ± 11%, p = 0.0394) with fewer arousals and micro-arousals. This occurred against a background of deterioration as ALSFRS-R, FVC, and SNIP declined. There was, however, no change in NIV status or the ALSFRS respiratory subscore, and the FVC decline was mostly due to impaired expiration. Supporting a better diaphragm function, apnoeas and hypopnoeas during REM sleep decreased. In conclusion, in these severe patients not expected to experience spontaneous improvements, diaphragm conditioning improved sleep and there were hints at diaphragm function changes.

  7. In patients with a tumour invading the phrenic nerve does prophylactic diaphragm plication improve postoperative lung function?

    Science.gov (United States)

    Beattie, Gwyn W; Dunn, William G; Asif, Mohammed

    2016-09-01

    A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was 'In patients with tumours involving the phrenic nerve, does prophylactic diaphragm plication improve lung function following tumour resection?' Using the reported search, 258 papers were found of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Three case reports and one case series represent 37 patients in the literature along with two relevant animal studies. Patients treated with prophylactic plication at the time of injury or sacrifice of the phrenic nerve had reduced radiological evidence of diaphragm paralysis, lower reported shortness of breath and reduced requirement for ventilatory support. In patients with prophylactic diaphragm plication and a concurrent pulmonary resection, the predicted postoperative lung function correlated closely with the postoperative measured FEV1, FVC and gas transfer. The postoperative measured FEV1 was reported as 86-98%, the FVC 82-89% and gas transfer 97% of the predicted values. Two animal models investigate the mechanics of respiration, spirometry and gas exchange following diaphragmatic plication. A randomized control study in four dogs measured a 50% reduction in tidal volume and respiratory rate, a 40% decrease in arterial PO2 and a 43% increase in arterial CO2 when the phrenic nerve was crushed in animals with a pneumonectomy but without prophylactic diaphragm plication. A further randomized control animal study with 28 dogs found that plicating the diaphragm after unilateral phrenic nerve transection resulted in a significant increase in tidal volume and lung compliance and a significant decrease in respiratory frequency and the work of breathing. Prophylactic diaphragm plication may preserve lung function, reduce the risk of

  8. Is Diaphragm Motion a Good Surrogate for Liver Tumor Motion?

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Juan [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); School of Information Science and Engineering, Shandong University, Jinan, Shandong (China); Cai, Jing [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Wang, Hongjun [School of Information Science and Engineering, Shandong University, Jinan, Shandong (China); Chang, Zheng; Czito, Brian G. [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Bashir, Mustafa R. [Department of Radiology, Duke University Medical Center, Durham, North Carolina (United States); Palta, Manisha [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Yin, Fang-Fang, E-mail: fangfang.yin@duke.edu [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States)

    2014-11-15

    Purpose: To evaluate the relationship between liver tumor motion and diaphragm motion. Methods and Materials: Fourteen patients with hepatocellular carcinoma (10 of 14) or liver metastases (4 of 14) undergoing radiation therapy were included in this study. All patients underwent single-slice cine–magnetic resonance imaging simulations across the center of the tumor in 3 orthogonal planes. Tumor and diaphragm motion trajectories in the superior–inferior (SI), anterior–posterior (AP), and medial–lateral (ML) directions were obtained using an in-house-developed normalized cross-correlation–based tracking technique. Agreement between the tumor and diaphragm motion was assessed by calculating phase difference percentage, intraclass correlation coefficient, and Bland-Altman analysis (Diff). The distance between the tumor and tracked diaphragm area was analyzed to understand its impact on the correlation between the 2 motions. Results: Of all patients, the mean (±standard deviation) phase difference percentage values were 7.1% ± 1.1%, 4.5% ± 0.5%, and 17.5% ± 4.5% in the SI, AP, and ML directions, respectively. The mean intraclass correlation coefficient values were 0.98 ± 0.02, 0.97 ± 0.02, and 0.08 ± 0.06 in the SI, AP, and ML directions, respectively. The mean Diff values were 2.8 ± 1.4 mm, 2.4 ± 1.1 mm, and 2.2 ± 0.5 mm in the SI, AP, and ML directions, respectively. Tumor and diaphragm motions had high concordance when the distance between the tumor and tracked diaphragm area was small. Conclusions: This study showed that liver tumor motion had good correlation with diaphragm motion in the SI and AP directions, indicating diaphragm motion in the SI and AP directions could potentially be used as a reliable surrogate for liver tumor motion.

  9. Diaphragm electromyographic activity following unilateral midcervical contusion injury in rats

    Science.gov (United States)

    Sieck, Gary C.

    2016-01-01

    Contusion-type injuries to the spinal cord are characterized by tissue loss and disruption of spinal pathways. Midcervical spinal cord injuries impair the function of respiratory muscles and may contribute to significant respiratory complications. This study systematically assessed the impact of a 100-kDy unilateral C4 contusion injury on diaphragm muscle activity across a range of motor behaviors in rats. Chronic diaphragm electromyography (EMG) was recorded before injury and at 1 and 7 days postinjury (DPI). Histological analyses assessed the extent of perineuronal net formation, white-matter sparing, and phrenic motoneuron loss. At 7 DPI, ∼45% of phrenic motoneurons were lost ipsilaterally. Relative diaphragm root mean square (RMS) EMG activity increased bilaterally across a range of motor behaviors by 7 DPI. The increase in diaphragm RMS EMG activity was associated with an increase in neural drive (RMS value at 75 ms after the onset of diaphragm activity) and was more pronounced during higher force, nonventilatory motor behaviors. Animals in the contusion group displayed a transient decrease in respiratory rate and an increase in burst duration at 1 DPI. By 7 days, following midcervical contusion, there was significant perineuronal net formation and white-matter loss that spanned 1 mm around the injury epicenter. Taken together, these findings are consistent with increased recruitment of remaining motor units, including more fatigable, high-threshold motor units, during higher force, nonventilatory behaviors. Changes in diaphragm EMG activity following midcervical contusion injury reflect complex adaptations in neuromotor control that may increase the risk of motor-unit fatigue and compromise the ability to sustain higher force diaphragm efforts. NEW & NOTEWORTHY The present study shows that unilateral contusion injury at C4 results in substantial loss of phrenic motoneurons but increased diaphragm muscle activity across a range of ventilatory and higher

  10. Effect of maternal steroid on developing diaphragm integrity.

    Directory of Open Access Journals (Sweden)

    Yong Song

    Full Text Available Antenatal steroids reduce the severity of initial respiratory distress of premature newborn babies but may have an adverse impact on other body organs. The study aimed to examine the effect of maternal steroids on postnatal respiratory muscle function during development and elucidate the mechanisms underlying the potential myopathy in newborn rats. Pregnant rats were treated with intramuscular injections of 0.5 mg/kg betamethasone 7 d and 3 d before birth. Newborn diaphragms were dissected for assessment of contractile function at 2 d, 7 d or 21 d postnatal age (PNA, compared with age-matched controls. The expression of myosin heavy chain (MHC isoforms and atrophy-related genes and activity of intracellular molecular signalling were measured using quantitative PCR and/or Western blot. With advancing PNA, neonatal MHC gene expression decreased progressively while MHC IIb and IIx isoforms increased. Protein metabolic signalling showed high baseline activity at 2 d PNA, and significantly declined at 7 d and 21 d. Antenatal administration of betamethasone significantly decreased diaphragm force production, fatigue resistance, total fast fibre content and anabolic signalling activity (Akt and 4E-BP1 in 21 d diaphragm. These responses were not observed in 2 d or 7 d postnatal diaphragm. Results demonstrate that maternal betamethasone treatment causes postnatal diaphragmatic dysfunction at 21 d PNA, which is attributed to MHC II protein loss and impairment of the anabolic signalling pathway. Developmental modifications in MHC fibre composition and protein signalling account for the age-specific diaphragm dysfunction.

  11. Microfluidic Pumps Containing Teflon [Trademark] AF Diaphragms

    Science.gov (United States)

    Willis, Peter; White, Victor; Grunthaner, Frank; Ikeda, Mike; Mathies, Richard A.

    2009-01-01

    Microfluidic pumps and valves based on pneumatically actuated diaphragms made of Teflon AF polymers are being developed for incorporation into laboratory-on-a-chip devices that must perform well over temperature ranges wider than those of prior diaphragm-based microfluidic pumps and valves. Other potential applications include implanted biomedical microfluidic devices, wherein the biocompatability of Teflon AF polymers would be highly advantageous. These pumps and valves have been demonstrated to function stably after cycling through temperatures from -125 to 120 C. These pumps and valves are intended to be successors to similar prior pumps and valves containing diaphragms made of polydimethylsiloxane (PDMS) [commonly known as silicone rubber]. The PDMS-containing valves ae designed to function stably only within the temperature range from 5 to 80 C. Undesirably, PDMS membranes are somwehat porous and retain water. PDMS is especially unsuitable for use at temperatures below 0 C because the formation of ice crystals increases porosity and introduces microshear.

  12. Audiovisual biofeedback improves diaphragm motion reproducibility in MRI

    Science.gov (United States)

    Kim, Taeho; Pollock, Sean; Lee, Danny; O’Brien, Ricky; Keall, Paul

    2012-01-01

    Purpose: In lung radiotherapy, variations in cycle-to-cycle breathing results in four-dimensional computed tomography imaging artifacts, leading to inaccurate beam coverage and tumor targeting. In previous studies, the effect of audiovisual (AV) biofeedback on the external respiratory signal reproducibility has been investigated but the internal anatomy motion has not been fully studied. The aim of this study is to test the hypothesis that AV biofeedback improves diaphragm motion reproducibility of internal anatomy using magnetic resonance imaging (MRI). Methods: To test the hypothesis 15 healthy human subjects were enrolled in an ethics-approved AV biofeedback study consisting of two imaging sessions spaced ∼1 week apart. Within each session MR images were acquired under free breathing and AV biofeedback conditions. The respiratory signal to the AV biofeedback system utilized optical monitoring of an external marker placed on the abdomen. Synchronously, serial thoracic 2D MR images were obtained to measure the diaphragm motion using a fast gradient-recalled-echo MR pulse sequence in both coronal and sagittal planes. The improvement in the diaphragm motion reproducibility using the AV biofeedback system was quantified by comparing cycle-to-cycle variability in displacement, respiratory period, and baseline drift. Additionally, the variation in improvement between the two sessions was also quantified. Results: The average root mean square error (RMSE) of diaphragm cycle-to-cycle displacement was reduced from 2.6 mm with free breathing to 1.6 mm (38% reduction) with the implementation of AV biofeedback (p-value biofeedback (p-value biofeedback (p-value = 0.012). The diaphragm motion reproducibility improvements with AV biofeedback were consistent with the abdominal motion reproducibility that was observed from the external marker motion variation. Conclusions: This study was the first to investigate the potential of AV biofeedback to improve the motion

  13. Improvement of CT-based treatment planning models of abdominal targets using static exhale imaging

    International Nuclear Information System (INIS)

    Ten Haken, R.K.; Balter, J.M.; Lam, K.L.; McGinn, C.J.; Lawrence, T.S.

    1996-01-01

    PURPOSE: CT based models of the patient that do not account for the motion of ventilation may not accurately predict the shape and position of critical abdominal structures. Without knowledge of the patient's ventilatory status during the CT scan, a planning target volume margin for the entire range of ventilation is required both inferior and superior to abdominal target volumes to ensure coverage. Also, dose-volume histograms and normal tissue complication probability (NTCP) estimates may be uncertain. Respiratory gating technology for imaging and treatment is not yet widely available. The purpose of the current study is to explore an intermediate step to improve the veracity of the patient model and reduce the treated volume by acquiring the CT data with the patients holding their breath at normal exhale. MATERIALS AND METHODS: The ventilatory time courses of diaphragm movement for 15 patients (with no special breathing instructions) were measured using digitized movies from the fluoroscope during simulation. On repeat simulations, the reproducibility of the diaphragm position at exhale was determined. A clinical protocol was developed for treatment based on exhale CT models. CT scans were acquired at normal exhale using a spiral scanner. Typical volumes were acquired using 5 mm slice thickness and a 1:1 pitch. The scan volume was divided into 2-3 segments, to allow the patient to breathe in between. Margins were placed about intrahepatic target volumes based on the ventilatory excursion inferior to the target, and on only the reproducibility of exhale position superior to the target. RESULTS: The average patient's diaphragm was located within 2 mm of the average exhale position for 50% of the typical ventilatory cycle. For inhale, this value was reduced to 10%, and for mid ventilation, 15%. The reproducibility of exhale position over multiple breathing cycles was 2 mm (2σ), as opposed to 4 mm for inhale. Combining the variation of exhale position and the

  14. Effect of hyperinflation on inspiratory function of the diaphragm.

    Science.gov (United States)

    Minh, V D; Dolan, G F; Konopka, R F; Moser, K M

    1976-01-01

    The inspiratory efficiency of the diaphragm during unilateral and bilateral phrenic stimulation (UEPS and BEPS) with constant stimulus was studied in seven dogs from FRC to 120% TLC. Alveolar pressures (PAl) were recorded during relaxation, BEPS and UEPS at each lung volume in the closed respiratory system. From the PAl-lung volume curves, tidal volume (VT), and pressure developed by the diaphragm (Pmus) were derived. Results are summarized below. a) Hyperinflation impaired the inspiratory efficiency of the diaphragm which behaved as an expiratory muscle beyond the lung volume of 103.7% TLC (Vinef). b) The diaphragm during UEPS became expiratory at the same Vinef as during (BEPS. C) The VT-lung volume relationship was linear during BEPS, allowing simple quantitation of VT loss with hyperinflation and prediction of Vinef. d) With only one phrenic nerve stimulated, the functional loss is less pronounced in VT than in Pmus, as compared to BEPS, indicating that the respiratory system was more compliant during UEPS than BEPS. This compliance difference from UEPS to BEPS diminished with severe hyperinflation.

  15. Determination of pulmonary volume by CT

    International Nuclear Information System (INIS)

    Kakinuma, Ryutaro

    1984-01-01

    The pulmonary volume overlapping the shadows of the mediastinum and the hilus pulmonis in frontal chest films was determined by means of CT. The pulmonary volume, between the levels of the aortic arch and just above the right diaphragm, overlapping the shadows of the mediastinum and the hilus, was one fourth of the entire pulmonary volume between the same levels. When the lungs overlapping the mediastinum and the hilus were divided into a region overlapping the spine and the aorta (region A) and another region (region B), the ratio of the volume of region A to that of region B was 1:3. CT is useful for quantitative roentgenological anatomy of the lungs. (author)

  16. A monitoring device for pressurised-air-driven diaphragm-based artificial heart assist devices

    NARCIS (Netherlands)

    Hoeben, F.P.; Hoeben, F.P.; de Mul, F.F.M.; Stokkink, J.S.D.; Stokkink, H.S.D.; Koelink, M.H.; Koelink, M.H.; Greve, Jan

    1992-01-01

    A non-invasive device has been developed to monitor the diaphragm position and the blood flow in artificial heart assist devices equipped with a pressurised-air-driven diaphragm. Light scattering from the diaphragm is used as a mechanism for measuring. Information about the position of several

  17. β-hydroxy-β-methylbutyrate (HMB) prevents sepsis-induced diaphragm dysfunction in mice.

    Science.gov (United States)

    Supinski, Gerald S; Callahan, Leigh A

    2014-06-01

    Infections induce severe respiratory muscle weakness. Currently there are no treatments for this important clinical problem. We tested the hypothesis that β-hydroxy-β-methylbutyrate (HMB) would prevent sepsis-induced diaphragm weakness. Four groups of adult male mice were studied: controls (saline-injected), sepsis (intraperitoneal lipopolysaccharide), sepsis+HMB (injected intravenously), and HMB. Diaphragm force generation and indices of caspase 3, calpain, 20S proteasomal subunit, and double-stranded RNA-dependent protein kinase (PKR) activation were assessed after 24h. Sepsis elicited large reductions in diaphragm specific force generation at all stimulation frequencies. Endotoxin also activated caspase 3, calpain, the 20S proteasomal subunit and PKR in the diaphragm. HMB blocked sepsis-induced caspase 3, 20S proteasomal and PKR activation, but did not prevent calpain activation. Most importantly, HMB administration significantly attenuated sepsis-induced diaphragm weakness, preserving muscle force generation at all stimulation frequencies (pHMB may prove to be an important therapy in infected patients, with the potential to increase diaphragm strength, to reduce the duration of mechanical ventilation and to decrease mortality in this patient population. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. An Accurate Study on Capacitive Microphone with Circular Diaphragm Using a Higher Order Elasticity Theory

    Directory of Open Access Journals (Sweden)

    Shakiba Dowlati

    Full Text Available Abstract This study has been undertaken to investigate the mechanical behavior of the capacitive microphone with clamped circular diaphragm using modified couple stress theory in comparison to the classical one. Presence of the length scale parameter in modified couple stress theory provides the means to evaluate the size effect on the microphone mechanical behavior. Investigating Pull-in phenomenon and dynamic behavior of the microphone are the matters provided due to the application of a step DC voltage. Also the effects of different air damping coefficients on dynamic pull-in voltage and pull-in time have been studied. The output level or sensitivity of the microphone has been studied by investigating the frequency response in term of magnitude for different length scale parameters to figure out how the length scale parameter affects on the sensitivity of the capacitive microphone. To achieve these ends, the nonlinear differential equation of the circular diaphragm has been extracted using Kirchhoff thin plate theory. Then, a Step-by-Step Linearization Method (SSLM has been used to escape from the nonlinearity of the differential equation. Afterwards, Galerkin-based reduced-order model has been applied to solve the obtained equation.

  19. Plasma Discharge Process in a Pulsed Diaphragm Discharge System

    Science.gov (United States)

    Duan, Jianjin; Hu, Jue; Zhang, Chao; Wen, Yuanbin; Meng, Yuedong; Zhang, Chengxu

    2014-12-01

    As one of the most important steps in wastewater treatment, limited study on plasma discharge process is a key challenge in the development of plasma applications. In this study, we focus on the plasma discharge process of a pulsed diaphragm discharge system. According to the analysis, the pulsed diaphragm discharge proceeds in seven stages: (1) Joule heating and heat exchange stage; (2) nucleated site formation; (3) plasma generation (initiation of the breakdown stage); (4) avalanche growth and plasma expansion; (5) plasma contraction; (6) termination of the plasma discharge; and (7) heat exchange stage. From this analysis, a critical voltage criterion for breakdown is obtained. We anticipate this finding will provide guidance for a better application of plasma discharges, especially diaphragm plasma discharges.

  20. Standardised uptake values from PET/CT images: comparison with conventional attenuation-corrected PET

    International Nuclear Information System (INIS)

    Souvatzoglou, M.; Ziegler, S.I.; Martinez, M.J.; Dzewas, G.; Schwaiger, M.; Bengel, F.; Busch, R.

    2007-01-01

    In PET/CT, CT-derived attenuation factors may influence standardised uptake values (SUVs) in tumour lesions and organs when compared with stand-alone PET. Therefore, we compared PET/CT-derived SUVs intra-individually in various organs and tumour lesions with stand-alone PET-derived SUVs. Thirty-five patients with known or suspected cancer were prospectively included. Sixteen patients underwent FDG PET using an ECAT HR+scanner, and subsequently a second scan using a Biograph Sensation 16PET/CT scanner. Nineteen patients were scanned in the reverse order. All images were reconstructed with an iterative algorithm (OSEM). Suspected lesions were grouped as paradiaphragmatic versus distant from the diaphragm. Mean and maximum SUVs were also calculated for brain, lung, liver, spleen and vertebral bone. The attenuation coefficients (μ values) used for correction of emission data (bone, soft tissue, lung) in the two data sets were determined. A body phantom containing six hot spheres and one cold cylinder was measured using the same protocol as in patients. Forty-six lesions were identified. There was a significant correlation of maximum and mean SUVs derived from PET and PET/CT for 14 paradiaphragmatic lesions (r=0.97 respectively; p<0.001 respectively) and for 32 lesions located distant from the diaphragm (r=0.87 and r=0.89 respectively; p<0.001 respectively). No significant differences were observed in the SUVs calculated with PET and PET/CT in the lesions or in the organs. In the phantom, radioactivity concentration in spheres calculated from PET and from PET/CT correlated significantly (r=0.99; p<0.001). SUVs of cancer lesions and normal organs were comparable between PET and PET/CT, supporting the usefulness of PET/CT-derived SUVs for quantification of tumour metabolism. (orig.)

  1. Investigation of the Durability of a Diaphragm for a Total Artificial Heart.

    Science.gov (United States)

    Gräf, Felix; Rossbroich, Ralf; Finocchiaro, Thomas; Steinseifer, Ulrich

    2016-10-01

    One of the most critical components regarding the durability of the ReinHeart total artificial heart (TAH) is its biocompatible diaphragm, which separates the drive unit from the ventricles. Hence, a durability tester was designed to investigate its required 5-year lifetime. The aim of this study was to prove the validity of accelerated testing of the polyurethane diaphragm. The durability tester allows simultaneous testing of 12 diaphragms and mimics physiological conditions. To accelerate the time of testing, it operates with an increased speed at a frequency of 8 Hz. To prove the correctness of this acceleration, a servo-hydraulic testing machine was used to study the effect of different frequencies and their corresponding loads. Thereby the viscoelastic behavior of the polyurethane was investigated. Additionally, high-speed video measurements were performed. The force against frequency and the high-speed video measurements showed constant behavior. In the range of 1-10 Hz, the maximum resulting forces varied by 3%, and the diaphragm movement was identical. Frequencies below 10 Hz allow a valid statement of the diaphragm's mechanical durability. Viscoelasticity of the polyurethane in the considered frequency-range is negligible. The accelerated durability test is applicable to polyurethane diaphragms, and the results are applicable to TAH use. The reliability of the diaphragm for a lifetime of 5 years was found to be 80% with a confidence of 62%. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  2. Phrenic nerves and diaphragms in sudden infant death syndrome.

    Science.gov (United States)

    Weis, J; Weber, U; Schröder, J M; Lemke, R; Althoff, H

    1998-01-30

    Disturbances of the respiratory system may be an important factor in the cascade of events leading to sudden infant death syndrome (SIDS). Even though the diaphragm is the major respiratory muscle in infants, little is known about alterations of this muscle and of the phrenic nerve in SIDS. In the present study, diaphragms and phrenic nerves of 24 SIDS infants and seven controls were analyzed. Morphometric analysis revealed only slightly larger cross sectional areas of phrenic nerve axons but no increase in myelin sheath thickness in SIDS cases. However, in one SIDS case, myelinated nerve fibre density was severely reduced. Using electron microscopy, several nerve fibres of SIDS infants showed focal accumulations of neurofilaments. Muscle fibre diameters in SIDS diaphragms were significantly larger compared to controls (P fibre ruptures and contracture bands were found. These prominent nonspecific ultrastructural alterations should advise caution in the interpretation of morphometric data. Thus, in some cases exemplified by one case of the present series, decreased density of phrenic nerve myelinated axons might contribute to SIDS. Still, the present results indicate that development of phrenic nerves and diaphragms is not delayed in most SIDS infants.

  3. Measurement of lung tumor motion using respiration-correlated CT

    International Nuclear Information System (INIS)

    Mageras, Gig S.; Pevsner, Alex; Yorke, Ellen D.; Rosenzweig, Kenneth E.; Ford, Eric C.; Hertanto, Agung; Larson, Steven M.; Lovelock, D. Michael; Erdi, Yusuf E.; Nehmeh, Sadek A.; Humm, John L.; Ling, C. Clifton

    2004-01-01

    Purpose: We investigate the characteristics of lung tumor motion measured with respiration-correlated computed tomography (RCCT) and examine the method's applicability to radiotherapy planning and treatment. Methods and materials: Six patients treated for non-small-cell lung carcinoma received a helical single-slice computed tomography (CT) scan with a slow couch movement (1 mm/s), while simultaneously respiration is recorded with an external position-sensitive monitor. Another 6 patients receive a 4-slice CT scan in a cine mode, in which sequential images are acquired for a complete respiratory cycle at each couch position while respiration is recorded. The images are retrospectively resorted into different respiration phases as measured with the external monitor (4-slice data) or patient surface displacement observed in the images (single-slice data). The gross tumor volume (GTV) in lung is delineated at one phase and serves as a visual guide for delineation at other phases. Interfractional GTV variation is estimated by scaling diaphragm position variations measured in gated radiographs at treatment with the ratio of GTV:diaphragm displacement observed in the RCCT data. Results: Seven out of 12 patients show GTV displacement with respiration of more than 1 cm, primarily in the superior-inferior (SI) direction; 2 patients show anterior-posterior displacement of more than 1 cm. In all cases, extremes in GTV position in the SI direction are consistent with externally measured extremes in respiration. Three patients show evidence of hysteresis in GTV motion, in which the tumor trajectory is displaced 0.2 to 0.5 cm anteriorly during expiration relative to inspiration. Significant (>1 cm) expansion of the GTV in the SI direction with respiration is observed in 1 patient. Estimated intrafractional GTV motion for gated treatment at end expiration is 0.6 cm or less in all cases; however; interfraction variation estimates (systematic plus random) are more than 1 cm in 3

  4. CT anatomy of right phrenic nerve and pulmonary ligament

    International Nuclear Information System (INIS)

    Berkmen, Y.M.; Kazam, E.; Auh, Y.

    1988-01-01

    The relationship between the right phrenic nerve and the right pulmonary ligament was studied in eight cadavers and 100 computed tomographic (CT) examinations. The pulmonary ligament originates below the inferior pulmonary vein and is constantly posterior to the inferior vena cava. The lower end of the right phrenic nerve, on the other hand, descends over the lateral surface of the inferior vena cava, accompanied by the right cardiophrenic artery. The nerve spreads over the diaphragm within a thick parietal pleural fold, wrapped in a fatty tissue, and this should not be confused with pulmonary ligament on CT

  5. Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker

    International Nuclear Information System (INIS)

    Vedam, S.S.; Kini, V.R.; Keall, P.J.; Ramakrishnan, V.; Mostafavi, H.; Mohan, R.

    2003-01-01

    The aim of this work was to quantify the ability to predict intrafraction diaphragm motion from an external respiration signal during a course of radiotherapy. The data obtained included diaphragm motion traces from 63 fluoroscopic lung procedures for 5 patients, acquired simultaneously with respiratory motion signals (an infrared camera-based system was used to track abdominal wall motion). During these sessions, the patients were asked to breathe either (i) without instruction, (ii) with audio prompting, or (iii) using visual feedback. A statistical general linear model was formulated to describe the relationship between the respiration signal and diaphragm motion over all sessions and for all breathing training types. The model parameters derived from the first session for each patient were then used to predict the diaphragm motion for subsequent sessions based on the respiration signal. Quantification of the difference between the predicted and actual motion during each session determined our ability to predict diaphragm motion during a course of radiotherapy. This measure of diaphragm motion was also used to estimate clinical target volume (CTV) to planning target volume (PTV) margins for conventional, gated, and proposed four-dimensional (4D) radiotherapy. Results from statistical analysis indicated a strong linear relationship between the respiration signal and diaphragm motion (p<0.001) over all sessions, irrespective of session number (p=0.98) and breathing training type (p=0.19). Using model parameters obtained from the first session, diaphragm motion was predicted in subsequent sessions to within 0.1 cm (1 σ) for gated and 4D radiotherapy. Assuming a 0.4 cm setup error, superior-inferior CTV-PTV margins of 1.1 cm for conventional radiotherapy could be reduced to 0.8 cm for gated and 4D radiotherapy. The diaphragm motion is strongly correlated with the respiration signal obtained from the abdominal wall. This correlation can be used to predict diaphragm

  6. The diaphragms of fenestrated endothelia: gatekeepers of vascular permeability and blood composition.

    Science.gov (United States)

    Stan, Radu V; Tse, Dan; Deharvengt, Sophie J; Smits, Nicole C; Xu, Yan; Luciano, Marcus R; McGarry, Caitlin L; Buitendijk, Maarten; Nemani, Krishnamurthy V; Elgueta, Raul; Kobayashi, Takashi; Shipman, Samantha L; Moodie, Karen L; Daghlian, Charles P; Ernst, Patricia A; Lee, Hong-Kee; Suriawinata, Arief A; Schned, Alan R; Longnecker, Daniel S; Fiering, Steven N; Noelle, Randolph J; Gimi, Barjor; Shworak, Nicholas W; Carrière, Catherine

    2012-12-11

    Fenestral and stomatal diaphragms are endothelial subcellular structures of unknown function that form on organelles implicated in vascular permeability: fenestrae, transendothelial channels, and caveolae. PV1 protein is required for diaphragm formation in vitro. Here, we report that deletion of the PV1-encoding Plvap gene in mice results in the absence of diaphragms and decreased survival. Loss of diaphragms did not affect the fenestrae and transendothelial channels formation but disrupted the barrier function of fenestrated capillaries, causing a major leak of plasma proteins. This disruption results in early death of animals due to severe noninflammatory protein-losing enteropathy. Deletion of PV1 in endothelium, but not in the hematopoietic compartment, recapitulates the phenotype of global PV1 deletion, whereas endothelial reconstitution of PV1 rescues the phenotype. Taken together, these data provide genetic evidence for the critical role of the diaphragms in fenestrated capillaries in the maintenance of blood composition. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Anatomic connections of the diaphragm influence of respiration on the body system

    Directory of Open Access Journals (Sweden)

    Bordoni B

    2013-07-01

    Full Text Available Bruno Bordoni,1 Emiliano Zanier2 1Rehabilitation Cardiology Institute of Hospitalization and Care with Scientific Address, S Maria Nascente Don Carlo Gnocchi Foundation, 2EdiAcademy, Milano, Italy Abstract: The article explains the scientific reasons for the diaphragm muscle being an important crossroads for information involving the entire body. The diaphragm muscle extends from the trigeminal system to the pelvic floor, passing from the thoracic diaphragm to the floor of the mouth. Like many structures in the human body, the diaphragm muscle has more than one function, and has links throughout the body, and provides the network necessary for breathing. To assess and treat this muscle effectively, it is necessary to be aware of its anatomic, fascial, and neurologic complexity in the control of breathing. The patient is never a symptom localized, but a system that adapts to a corporeal dysfunction. Keywords: diaphragm, fascia, phrenic nerve, vagus nerve, pelvis

  8. Displacement and resonance behaviors of a piezoelectric diaphragm driven by a double-sided spiral electrode

    KAUST Repository

    Shen, Zhiyuan; Olfatnia, Mohammad; Miao, Jianmin; Wang, Zhihong

    2012-01-01

    This paper presents the design of a lead zirconate titanate (PZT) diaphragm actuated by double-sided patterned electrodes. Au/Cr electrodes were deposited on bulk PZT wafers by sputtering while patterned by a lift-off process. SU-8 thick film

  9. Spiral hydro-CT of the pancreas in the thin-slice method

    International Nuclear Information System (INIS)

    Richter, G.M.; Simon, C.; Hoffmann, V.; DeBernardinis, M.; Seelos, R.; Senninger, N.; Kauffmann, G.W.

    1996-01-01

    In an open prospective study, 151 patients with a suspected pancreatic neoplasm based on clinical, laboratory or other imaging data were examined between May 94 and October 95. Our newly developed Hydro-CT methodology included intravenous injection of 40 mg N-butylscopolaminium bromide (Buscopan) for intestinal paralysis, gastric and duodenal wall distension by oral administration of an average of 1.5 l warm tap water, 30 RAO patient positioning, an individualized contrast injection technique as determined beforehand by time-to-peak measurement in the portal vein and thin-slice spiral CT (3 mm increment, 6 mm table feed and 3 mm secondary reconstruction). A detailed evaluation form was used to assess (1) tumor detection rate, (2) differentiation of malignant versus benign disease, (3) differential diagnosis, and (4) accuracy of assessment of resectability by identification of infiltration into adjacent organs and vessel structures relevant for resectability such as splenic, superior mesenteric, portal vein and celiac trunk, superior mesenteric, splenic and hepatic arteries. As the gold standard for positive tumor detection surgery and microscopic diagnosis were used, and for negative tumor detection an event-free survival of 6 months. Almost all examinations were well tolerated. In only 4% was on-site administration of a gastric tube required because of vomiting. In 2% of the patients a slight allergic reaction to be contrast medium was seen. The prevalence of a pancreatic neoplasm was 38%. In tumor detection Hydro-CT reached an overall accuracy of 97.4% with a sensitivity of 100% and a specificity of 95.9%. In the differentiation of benign versus malignant disease Hydro-CT reached an overall accuracy of 89.7% with a sensitivity of 92.5% and a specificity of 83.3%. The prevalence of a pancreatic carcinoma was 24%; 4% other malignant tumors were found (distal common bile duct carcinoma, cystadenocarcinoma). (orig./MG) [de

  10. Continuity diaphragm for skewed continuous span precast prestressed concrete girder bridges.

    Science.gov (United States)

    2004-10-01

    Continuity diaphragms used on skewed bents in prestressed girder bridges cause difficulties in detailing and : construction. Details for bridges with large diaphragm skew angles (>30) have not been a problem for LA DOTD. : However, as the skew angl...

  11. Experimental Characterization of Piezoelectric Radial Field Diaphragms for Fluidic Control

    Science.gov (United States)

    Bryant, R. G.; Kavli, S. E.; Thomas, R. A., Jr.; Darji, K. J.; Mossi, K. M.

    2004-01-01

    NASA has recently developed a new piezoelectric actuator, the Radial Field Diaphragm or RFD. This actuator uses a radially-directed electric field to generate concentric out-of-plane (Z-axis) motion that allows this packaged device to be used as a pump or valve diaphragm. In order to efficiently use this new active device, experimental determination of pressure, flow rate, mechanical work, power consumption and overall efficiency needs to be determined by actually building a pump. However, without an optimized pump design, it is difficult to assess the quality of the data, as these results are inherent to the actual pump. Hence, separate experiments must be conducted in order to generate independent results to help guide the design criteria and pump quality. This paper focuses on the experiments used to generate the RFD's operational parameters and then compares these results to the experimentally determined results of several types of ball pumps. Also discussed are how errors are inherently introduced into the experiments, the pump design, experimental hardware and their effects on the overall system efficiency.

  12. Effectiveness of thin-slice axial images of multidetector row CT for visualization of bronchial artery before bronchial arterial embolization

    International Nuclear Information System (INIS)

    Shida, Yoshitaka; Hasuo, Kanehiro; Aibe, Hitoshi; Kubo, Yuko; Terashima, Kotaro; Kinjo, Maya; Kamano, H.; Yoshida, Atsuko

    2008-01-01

    We assessed the ability of visualization of bronchial artery (BA) by using thin-slice axial images of 4-detector multidetector row CT in 65 patients with hemoptysis. In all patients, the origins of BA were well identified with observation of consecutive axial images with 1 mm thickness by paging method and bronchial arterial embolization (BAE) was performed successfully. Thin-slice axial images were considered to be useful to recognize BA and to perform BAE in patients with hemoptysis. (author)

  13. Failure analysis of globe control valves with spring-diaphragm actuator for nuclear power plant applications

    International Nuclear Information System (INIS)

    Khan, M.R.; Chen, W.W.H.; Wang, T.Y.

    1997-01-01

    The results of the failure analysis of a globe control valve with spring-diaphragm actuator indicated that the diaphragm failed because the service loading is close to the strength of the diaphragm. The resulting impact force is significantly larger than the plug guide strength and that cause it to bulge out after the impact. To improve the valve performance, proper torque should be used to tighten the actuator diaphragm case fasteners. A stronger actuator diaphragm could be used to provide additional safety margin during operation. Stiffening the plug guide may avoid jamming the bushing

  14. Novel diaphragm for electrolytic cells. Final report

    International Nuclear Information System (INIS)

    The basic intent of these studies is to produce a diaphragm permeable to two types of ions, which have properties which are similar to those of asbestos. PTFE in the form of fabric is rendered hydrophilic by grafting monomer acrylic acid by a radio-chemical technique; two methods were utilized to do this: - Direct radio-chemical method under radiation - Pre-irradiation method in air under radiation and accelerated electronic radiation. The monomer acrylic acid was grafted in the presence or non-presence of cross-linking agents, the latter before developing a resistance derived from the diaphragms obtained at the agressivity of the medium in which they would be utilized

  15. Laterally Driven Resonant Pressure Sensor with Etched Silicon Dual Diaphragms and Combined Beams

    Directory of Open Access Journals (Sweden)

    Xiaohui Du

    2016-01-01

    Full Text Available A novel structure of the resonant pressure sensor is presented in this paper, which tactfully employs intercoupling between dual pressure-sensing diaphragms and a laterally driven resonant strain gauge. After the resonant pressure sensor principle is introduced, the coupling mechanism of the diaphragms and resonator is analyzed and the frequency equation of the resonator based on the triangle geometry theory is developed for this new coupling structure. The finite element (FE simulation results match the theoretical analysis over the full scale of the device. This pressure sensor was first fabricated by dry/wet etching and thermal silicon bonding, followed by vacuum-packaging using anodic bonding technology. The test maximum error of the fabricated sensor is 0.0310%F.S. (full scale in the range of 30 to 190 kPa, its pressure sensitivity is negative and exceeding 8 Hz/kPa, and its Q-factor reaches 20,000 after wafer vacuum-packaging. A novel resonant pressure sensor with high accuracy is presented in this paper.

  16. Characteristics research of pressure sensor based on nanopolysilicon thin films resistors

    Science.gov (United States)

    Zhao, Xiaofeng; Li, Dandan; Wen, Dianzhong

    2017-10-01

    To further improve the sensitivity temperature characteristics of pressure sensor, a kind of pressure sensor taking nanopolysilicon thin films as piezoresistors is proposed in this paper. On the basis of the microstructure analysis by X-ray diffraction (XRD) and scanning electron microscope (SEM) tests, the preparing process of nanopolysilicon thin films is optimized. The effects of film thickness and annealing temperature on the micro-structure of nanopolysilicon thin films were studied, respectively. In order to realize the measurement of external pressure, four nanopolysilicon thin films resistors were arranged at the edges of square silicon diaphragm connected to a Wheatstone bridge, and the chip of the sensor was designed and fabricated on a 〈100〉 orientation silicon wafer by microelectromechanical system (MEMS) technology. Experimental result shows that when I = 6.80 mA, the sensitivity of the sensor PS-1 is 0.308 mV/kPa, and the temperature coefficient of sensitivity (TCS) is about -1742 ppm/∘C in the range of -40-140∘C. It is possible to obviously improve the sensitivity temperature characteristics of pressure sensor by the proposed sensors.

  17. Diaphragm Pump With Resonant Piezoelectric Drive

    Science.gov (United States)

    Izenson, Michael G.; Kline-Schoder, Robert J.; Shimko, Martin A.

    2007-01-01

    A diaphragm pump driven by a piezoelectric actuator is undergoing development. This pump is intended to be a prototype of lightweight, highly reliable pumps for circulating cooling liquids in protective garments and high-power electronic circuits, and perhaps for some medical applications. The pump would be highly reliable because it would contain no sliding seals or bearings that could wear, the only parts subject to wear would be two check valves, and the diaphragm and other flexing parts could be designed, by use of proven methods, for extremely long life. Because the pump would be capable of a large volumetric flow rate and would have only a small dead volume, its operation would not be disrupted by ingestion of gas, and it could be started reliably under all conditions. The prior art includes a number piezoelectrically actuated diaphragm pumps. Because of the smallness of the motions of piezoelectric actuators (typical maximum strains only about 0.001), the volumetric flow rates of those pumps are much too small for typical cooling applications. In the pump now undergoing development, mechanical resonance would be utilized to amplify the motion generated by the piezoelectric actuator and thereby multiply the volumetric flow rate. The prime mover in this pump would be a stack of piezoelectric ceramic actuators, one end of which would be connected to a spring that would be part of a spring-and-mass resonator structure. The mass part of the resonator structure would include the pump diaphragm (see Figure 1). Contraction of the spring would draw the diaphragm to the left, causing the volume of the fluid chamber to increase and thereby causing fluid to flow into the chamber. Subsequent expansion of the spring would push the diaphragm to the right, causing the volume of the fluid chamber to decrease, and thereby expelling fluid from the chamber. The fluid would enter and leave the chamber through check valves. The piezoelectric stack would be driven electrically to

  18. (18)F-FDG PET/CT Findings in a Patient with Chikungunya Virus Infection

    DEFF Research Database (Denmark)

    Rose, Michala Vaaben; Kjaer, Anna Sophie L; Markova, Elena

    2017-01-01

    We present a case demonstrating the diagnostic work-up and follow-up of a patient with Chikungunya infection. An (18)F-FDG PET/CT performed four weeks after debut of symptoms revealed pathological (18)F-FDG uptake in enlarged lymph nodes on both side of the diaphragm, and inflammation of both...

  19. Cough induced rib fracture, rupture of the diaphragm and abdominal herniation

    Directory of Open Access Journals (Sweden)

    Wurl Peter

    2006-11-01

    Full Text Available Abstract Cough can be associated with many complications. In this article, we present a 59 year old male patient with a very rare combination of a cough related stress fracture of the ninth rib, a traumatic rupture of the diaphragm, and an abdominal wall herniation. The hernia was repaired through surgical treatment without bowel resection, the diaphragm and the internal and oblique abdominal muscle were adapted, and the abdomen was reinforced with a prolene net. Although each individual injury is well documented in the literature, the combination of rib fracture, abdominal herniation and diaphragm rupture has not been reported.

  20. Internally-cooled centrifugal compressor with cooling jacket formed in the diaphragm

    Science.gov (United States)

    Moore, James J.; Lerche, Andrew H.; Moreland, Brian S.

    2014-08-26

    An internally-cooled centrifugal compressor having a shaped casing and a diaphragm disposed within the shaped casing having a gas side and a coolant side so that heat from a gas flowing though the gas side is extracted via the coolant side. An impeller disposed within the diaphragm has a stage inlet on one side and a stage outlet for delivering a pressurized gas to a downstream connection. The coolant side of the diaphragm includes at least one passageway for directing a coolant in a substantially counter-flow direction from the flow of gas through the gas side.

  1. Short linear shadows connecting pulmonary segmental arteries to oblique fissures in volumetric thin-section CT images: comparing CT, micro-CT and histopathology

    International Nuclear Information System (INIS)

    Guan, Chun-Shuang; Ma, Da-Qing; Chen, Jiang-Hong; Chen, Bu-Dong; Cui, Dun; Zhang, Yan-Song; Liu, Wei-Hua

    2016-01-01

    To retrospectively evaluate short linear shadows connecting pulmonary segmental arteries to oblique fissures in thin-section CT images and determine their anatomical basis. CT scanning was performed on 108 patients and 11 lung specimens with no lung diseases around the oblique fissures or hilar. Two radiologists evaluated the imaging. The parameters included length, thickness of short linear shadows, pulmonary segmental artery variations, and traction interlobar fissures, etc. The short linear shadows were not related to sex, age, or smoking history. The lengths of the short linear shadows were generally within 10 mm. The thicknesses of the short linear shadows ranged from 1 to 2 mm. Of the patients, 26.9 % showed pulmonary segmental artery variations; 66.7 % of short linear shadows pulled oblique fissures. In three-dimensional images, the short linear shadows appeared as arc planes, with one side edge connected to the oblique fissure, one side edge connected to a pulmonary segmental artery. On the tissue slices, the short linear shadow exhibited a band structure composed of connective tissues, small blood vessels, and small lymphatic vessels. Short linear shadows are a type of normal intrapulmonary membranes and can maintain the integrity of the oblique fissures and hilar structure. (orig.)

  2. Progressive Diaphragm Atrophy in Pediatric Acute Respiratory Failure.

    Science.gov (United States)

    Glau, Christie L; Conlon, Thomas W; Himebauch, Adam S; Yehya, Nadir; Weiss, Scott L; Berg, Robert A; Nishisaki, Akira

    2018-02-05

    Diaphragm atrophy is associated with delayed weaning from mechanical ventilation and increased mortality in critically ill adults. We sought to test for the presence of diaphragm atrophy in children with acute respiratory failure. Prospective, observational study. Single-center tertiary noncardiac PICU in a children's hospital. Invasively ventilated children with acute respiratory failure. Diaphragm thickness at end-expiration and end-inspiration were serially measured by ultrasound in 56 patients (median age, 17 mo; interquartile range, 5.5-52), first within 36 hours of intubation and last preceding extubation. The median duration of mechanical ventilation was 140 hours (interquartile range, 83-201). At initial measurement, thickness at end-expiration was 2.0 mm (interquartile range, 1.8-2.5) and thickness at end-inspiration was 2.5 mm (interquartile range, 2-2.8). The change in thickness at end-expiration during mechanical ventilation between first and last measurement was -13.8% (interquartile range, -27.4% to 0%), with a -3.4% daily atrophy rate (interquartile range, -5.6 to 0%). Thickening fraction = ([thickness at end-inspiration - thickness at end-expiration]/thickness at end-inspiration) throughout the course of mechanical ventilation was linearly correlated with spontaneous breathing fraction (beta coefficient, 9.4; 95% CI, 4.2-14.7; p = 0.001). For children with a period of spontaneous breathing fraction less than 0.5 during mechanical ventilation, those with exposure to a continuous neuromuscular blockade infusion (n = 15) had a significantly larger decrease in thickness at end-expiration compared with children with low spontaneous breathing fraction who were not exposed to a neuromuscular blockade infusion (n = 18) (-16.4%, [interquartile range, -28.4% to -7.0%] vs -7.3%; [interquartile range, -10.9% to -0%]; p = 0.036). Diaphragm atrophy is present in children on mechanical ventilation for acute respiratory failure. Diaphragm contractility, measured as

  3. Acute appendicitis: sensitivity, specificity and diagnostic accuracy of thin-section contrast-enhanced CT findings

    International Nuclear Information System (INIS)

    Lee, Ji Yon; Choi, Dong Il; Park, Hae Won; Lee, Young Rae; Kook, Shin Ho; Kwang, Hyon Joo; Kim, Seung Kwon; Chung, Eun Chul

    2002-01-01

    To assess the sensitivity, specificity, and diagnostic accuracy of individual contrast-enhanced helical CT findings of acute appendicitis. We retrospectively reviewed the appendiceal helical CT scans, obtained after intravenous contrast administration (abdomen; 7-mm collimation, abdominopelvic junction; 5-mm collimation), of 50 patients with surgically proven acute appendicitis and 112 with alternative diagnoses. The following parameters were analysed by three radiologists: enlarged appendix (>6 mm in diameter), appendiceal wall thickening, appendiceal wall enhancement, no identification of the appendix, appendicolith(s), (appendiceal) intraluminal air, abscess, lymphadenopathy, terminal ileal wall thickening, focal cecal apical thickening, focal colonic wall thickening, and segmental colonic wall thickening. The CT findings of acute appendicitis that statistically distinguished it from alternative diagnoses were an enlarged appendix (sensitivity; 92%, specificity; 93%, diagnostic accuracy; 93%), appendiceal wall thickening (for these three parameters: 68%, 96% and 88%, respectively), periappendiceal fat stranding (90%, 79%, 82%), appendiceal wall enhancement (72%, 86%, 82%), appendicolith (16%, 100%, 74%), and focal cecal apical thickening (14%, 100%, 74%) (for each, p<0305). On thin-section contrast-enhanced helical CT, an enlarged appendix and periappendiceal fat stranding were found in 90% or more patients with acute appendicitis. Appendiceal wall thickening and enhancement were alearly demonstrated and significant findings for diagnosis. Less common but specific findings include appendicolith, focal cecal apical thickening and intramural air, can also help us establish a diagnosis of acute appendicitis

  4. Computer simulation analysis of normal and abnormal development of the mammalian diaphragm

    Science.gov (United States)

    Fisher, Jason C; Bodenstein, Lawrence

    2006-01-01

    Background Congenital diaphragmatic hernia (CDH) is a birth defect with significant morbidity and mortality. Knowledge of diaphragm morphogenesis and the aberrations leading to CDH is limited. Although classical embryologists described the diaphragm as arising from the septum transversum, pleuroperitoneal folds (PPF), esophageal mesentery and body wall, animal studies suggest that the PPF is the major, if not sole, contributor to the muscular diaphragm. Recently, a posterior defect in the PPF has been identified when the teratogen nitrofen is used to induce CDH in fetal rodents. We describe use of a cell-based computer modeling system (Nudge++™) to study diaphragm morphogenesis. Methods and results Key diaphragmatic structures were digitized from transverse serial sections of paraffin-embedded mouse embryos at embryonic days 11.5 and 13. Structure boundaries and simulated cells were combined in the Nudge++™ software. Model cells were assigned putative behavioral programs, and these programs were progressively modified to produce a diaphragm consistent with the observed anatomy in rodents. Homology between our model and recent anatomical observations occurred under the following simulation conditions: (1) cell mitoses are restricted to the edge of growing tissue; (2) cells near the chest wall remain mitotically active; (3) mitotically active non-edge cells migrate toward the chest wall; and (4) movement direction depends on clonal differentiation between anterior and posterior PPF cells. Conclusion With the PPF as the sole source of mitotic cells, an early defect in the PPF evolves into a posteromedial diaphragm defect, similar to that of the rodent nitrofen CDH model. A posterolateral defect, as occurs in human CDH, would be more readily recreated by invoking other cellular contributions. Our results suggest that recent reports of PPF-dominated diaphragm morphogenesis in the rodent may not be strictly applicable to man. The ability to recreate a CDH defect

  5. Computer simulation analysis of normal and abnormal development of the mammalian diaphragm

    Directory of Open Access Journals (Sweden)

    Bodenstein Lawrence

    2006-02-01

    Full Text Available Abstract Background Congenital diaphragmatic hernia (CDH is a birth defect with significant morbidity and mortality. Knowledge of diaphragm morphogenesis and the aberrations leading to CDH is limited. Although classical embryologists described the diaphragm as arising from the septum transversum, pleuroperitoneal folds (PPF, esophageal mesentery and body wall, animal studies suggest that the PPF is the major, if not sole, contributor to the muscular diaphragm. Recently, a posterior defect in the PPF has been identified when the teratogen nitrofen is used to induce CDH in fetal rodents. We describe use of a cell-based computer modeling system (Nudge++™ to study diaphragm morphogenesis. Methods and results Key diaphragmatic structures were digitized from transverse serial sections of paraffin-embedded mouse embryos at embryonic days 11.5 and 13. Structure boundaries and simulated cells were combined in the Nudge++™ software. Model cells were assigned putative behavioral programs, and these programs were progressively modified to produce a diaphragm consistent with the observed anatomy in rodents. Homology between our model and recent anatomical observations occurred under the following simulation conditions: (1 cell mitoses are restricted to the edge of growing tissue; (2 cells near the chest wall remain mitotically active; (3 mitotically active non-edge cells migrate toward the chest wall; and (4 movement direction depends on clonal differentiation between anterior and posterior PPF cells. Conclusion With the PPF as the sole source of mitotic cells, an early defect in the PPF evolves into a posteromedial diaphragm defect, similar to that of the rodent nitrofen CDH model. A posterolateral defect, as occurs in human CDH, would be more readily recreated by invoking other cellular contributions. Our results suggest that recent reports of PPF-dominated diaphragm morphogenesis in the rodent may not be strictly applicable to man. The ability to

  6. Effect of Elastase-induced Emphysema on the Force-generating Ability of the Diaphragm

    Science.gov (United States)

    Supinski, Gerald S.; Kelsen, Steven G.

    1982-01-01

    The effect of emphysema on the ability of the diaphragm to generate force was examined in costal diaphragm muscle strips from 10 Golden hamsters killed 18 mo after intratracheal injection of pancreatic elastase in a dose producing hyperinflation (mean total lung capacity [TLC] = 163% of control) and generalized panacinar emphysema. 13 saline-injected normal animals served as controls. The time course of isometric tension and the effect of alterations in muscle fiber and sarcomere length on the isometric tension (T) generated in response to tetanizing electrical stimuli (length-tension [L-T] relationship) were examined. Elastase administration caused an increase in diaphragm muscle thickness and reduction in the length of costal diaphragm muscle fibers measured in situ. Emphysema significantly increased the maximum tetanic tension as a result of hypertrophy. Maximal tension corrected for increases in muscle cross-sectional area (T/cm2), however, was the same in emphysematous (E) and control (C) animals. Emphysema also shifted the muscle fiber L-T curve of the diaphragm but not of a control muscle, the soleus, toward shorter lengths. In contrast to the effects of E on the diaphragm muscle fiber L-T curve, the sarcomere L-T curve was the same in E and C. Since the length at which tension was maximal correlated closely with sarcomere number (r = 0.94; P < 0.001) reduction in the number of sarcomeres in series in muscles from emphysematous animals appeared to explain the shift in the muscle fiber L-T curve. We conclude that in elastase-induced emphysema adaptive changes both in diaphragm cross-sectional area and sarcomere number augment the force-generating ability of the diaphragm. We speculate that changes in sarcomere number compensate for alterations in muscle fiber length resulting from chronic hyperinflation of the thorax, while diaphragmatic muscle hypertrophy represents a response to changes in respiratory load and/or diaphragm configuration (La

  7. Barrier Methods of Birth Control: Spermicide, Condom, Sponge, Diaphragm, and Cervical Cap

    Science.gov (United States)

    ... ACOG Barrier Methods of Birth Control: Spermicide, Condom, Sponge, Diaphragm, and Cervical Cap Home For Patients Search ... Format Barrier Methods of Birth Control: Spermicide, Condom, Sponge, Diaphragm, and Cervical Cap Contraception What are barrier ...

  8. Posterior diaphragmatic defect detected on chest CT: the incidence according to age and the lateral chest radiographic appearances

    International Nuclear Information System (INIS)

    Lee, Son Youl; Choi, Yo Won; Jeon, Seok Chol; Heo, Jeong Nam; Park, Choong Ki

    2007-01-01

    We wanted to investigate the incidence of posterior diaphragmatic defect on chest CT in various age groups and its lateral chest radiographic appearances. The chest CT scans of 78 patients of various ages with posterior diaphragmatic defect were selected among 1,991 patients, and they were analyzed for the incidence of defect in various age groups, the defect location and the herniated contents. Their lateral chest radiographs were analyzed for the shape of the posterior diaphragm and the posterior costophrenic sulcus. The patients' ages ranged from 34 to 87 with the tendency of a higher incidence in the older patients. The defect most frequently involved the medial two thirds (n = 49, 50.4%) and middle one third (n = 36, 37%) of the posterior diaphragm. The retroperitoneal fat was herniated into the thorax through the defect in all patients, and sometimes with the kidney (n = 8). Lateral chest radiography showed a normal diaphragmatic contour (n = 51, 49.5%), blunting of the posterior costophrenic sulcus (n = 41, 39.8%), focal humping of the posterior diaphragm (n = 7, 6.8%), or upward convexity (n = 4, 3.9%) of the posterior costophrenic sulcus on the affected side. The posterior diaphragmatic defect discovered in asymptomatic patients who are without a history of peridiaphragmatic disease is most likely acquired, and this malady increases in incidence according to age. An abnormal contour of the posterior diaphragm or the costophrenic sulcus on a lateral chest radiograph may be a finding of posterior diaphragmatic defect

  9. Diaphragm disease of the small intestine: an interesting case report.

    Science.gov (United States)

    Ullah, Sana; Ajab, Shereen; Rao, Rajashekhar; Raghunathan, Girish; DaCosta, Philip

    2015-06-01

    Diaphragm disease of small intestine usually presents with nonspecific clinical features. Radiological investigations often fail to differentiate it from small intestinal tumors and inflammatory bowel disease. It is therefore diagnosed on final histology after surgical resection. We hereby report an interesting case of a suspected small bowel tumor later diagnosed as diaphragm disease on histology. © The Author(s) 2014.

  10. Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines

    International Nuclear Information System (INIS)

    Coselmon, Martha M.; Balter, James M.; McShan, Daniel L.; Kessler, Marc L.

    2004-01-01

    The advent of dynamic radiotherapy modeling and treatment techniques requires an infrastructure to weigh the merits of various interventions (breath holding, gating, tracking). The creation of treatment planning models that account for motion and deformation can allow the relative worth of such techniques to be evaluated. In order to develop a treatment planning model of a moving and deforming organ such as the lung, registration tools that account for deformation are required. We tested the accuracy of a mutual information based image registration tool using thin-plate splines driven by the selection of control points and iterative alignment according to a simplex algorithm. Eleven patients each had sequential CT scans at breath-held normal inhale and exhale states. The exhale right lung was segmented from CT and served as the reference model. For each patient, thirty control points were used to align the inhale CT right lung to the exhale CT right lung. Alignment accuracy (the standard deviation of the difference in the actual and predicted inhale position) was determined from locations of vascular and bronchial bifurcations, and found to be 1.7, 3.1, and 3.6 mm about the RL, AP, and IS directions. The alignment accuracy was significantly different from the amount of measured movement during breathing only in the AP and IS directions. The accuracy of alignment including thin-plate splines was more accurate than using affine transformations and the same iteration and scoring methodology. This technique shows promise for the future development of dynamic models of the lung for use in four-dimensional (4-D) treatment planning

  11. Hydrogel based sensor arrays (2 × 2) with perforated piezoresistive diaphragms for metabolic monitoring (in vitro).

    Science.gov (United States)

    Orthner, M P; Lin, G; Avula, M; Buetefisch, S; Magda, J; Rieth, L W; Solzbacher, F

    2010-03-19

    This report details the first experimental results from novel hydrogel sensor array (2 × 2) which incorporates analyte diffusion pores into a piezoresistive diaphragm for the detection of hydrogel swelling pressures and hence chemical concentrations. The sensor assembly was comprised of three components, the active four sensors, HPMA/DMA/TEGDMA (hydroxypropyl methacrylate (HPMA), N,N-dimethylaminoethyl methacrylate (DMA) and crosslinker tetra-ethyleneglycol dimethacrylate (TEGDMA)) hydrogel, and backing plate. Each of the individual sensors of the array can be used with various hydrogels used to measure the presence of a number of stimuli including pH, ionic strength, and glucose concentrations. Ideally, in the future, these sensors will be used for continuous metabolic monitoring applications and implanted subcutaneously. In this paper and to properly characterize the sensor assembly, hydrogels sensitive to changes ionic strength were synthesized using hydroxypropyl methacrylate (HPMA), N,N-dimethylaminoethyl methacrylate (DMA) and crosslinker tetra-ethyleneglycol dimethacrylate (TEGDMA) and inserted into the sensor assembly. This hydrogel quickly and reversibly swells when placed environments of physiological buffer solutions (PBS) with ionic strengths ranging from 0.025 to 0.15 M, making it ideal for proof-of-concept testing and initial characterization. The assembly was wire bonded to a printed circuit board and coated with 3 ± 0.5 μm of Parylene-C using chemical vapor deposition (CVD) to protect the sensor and electrical connections during ionic strength wet testing. Two versions of sensors were fabricated for comparison, the first incorporated diffusion pores into the diaphragm, and the second used a solid diaphragm with perforated backing plate. This new design (perforated diaphragm) was shown to have slightly higher sensitivity than solid diaphragm sensors with separate diffuse backing plates when coupled with the hydrogel. The sensitivities for the 1 mm

  12. Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging

    International Nuclear Information System (INIS)

    Balter, James M.; Lam, Kwok L.; McGinn, Cornealeus J.; Lawrence, Theodore S.; Haken, Randall K. ten

    1998-01-01

    Purpose: CT-based models of the patient that do not account for the motion of ventilation may not accurately predict the shape and position of critical abdominal structures. Respiratory gating technology for imaging and treatment is not yet widely available. The purpose of the current study is to explore an intermediate step to improve the veracity of the patient model and reduce the treated volume by acquiring the CT data with the patients holding their breath at normal exhale. Methods and Materials: The ventilatory time courses of diaphragm movement for 15 patients (with no special breathing instructions) were measured using digitized movies from the fluoroscope during simulation. A subsequent clinical protocol was developed for treatment based on exhale CT models. CT scans (typically 3.5-mm slice thickness) were acquired at normal exhale using a spiral scanner. The scan volume was divided into two to three segments, to allow the patient to breathe in between. Margins were placed about intrahepatic target volumes based on the ventilatory excursion inferior to the target, and on only the reproducibility of exhale position superior to the target. Results: The average patient's diaphragm remained within 25% of the range of ventilatory excursion from the average exhale position for 42% of the typical breathing cycle, and within 25% of the range from the average inhale position for 15% of the cycle. The reproducibility of exhale position over multiple breathing cycles was 0.9 mm (2σ), as opposed to 2.6 mm for inhale. Combining the variation of exhale position and the uncertainty in diaphragm position from CT slices led to typical margins of 10 mm superior to the target, and 19 mm inferior to the target, compared to margins of 19 mm in both directions under our prior protocol of margins based on free-breathing CT studies. For a typical intrahepatic target, these smaller volumes resulted in a 3.6% reduction in V eff for the liver. Analysis of portal films shows proper

  13. Diaphragm adaptations in patients with COPD.

    NARCIS (Netherlands)

    Ottenheijm, C.A.C.; Heunks, L.M.A.; Dekhuijzen, P.N.R.

    2008-01-01

    Inspiratory muscle weakness in patients with COPD is of major clinical relevance. For instance, maximum inspiratory pressure generation is an independent determinant of survival in severe COPD. Traditionally, inspiratory muscle weakness has been ascribed to hyperinflation-induced diaphragm

  14. The value of sub-stages and thin slices for the assessment of the medial clavicular epiphysis: a prospective multi-center CT study.

    Science.gov (United States)

    Wittschieber, Daniel; Schulz, Ronald; Vieth, Volker; Küppers, Martin; Bajanowski, Thomas; Ramsthaler, Frank; Püschel, Klaus; Pfeiffer, Heidi; Schmidt, Sven; Schmeling, Andreas

    2014-06-01

    The clavicle plays an important role for forensic age estimation in living individuals, particularly with regard to the age of majority. The present prospective study aims to evaluate the age-dependent ossification process of the medial clavicular epiphysis in order to establish the clavicular sub-stages introduced in 2010 as well as the advantages and possibilities of thin-slice computed tomography (CT). For this purpose, 0.6 mm thin-slice CT scans of sternoclavicular joints of 572 bodies aged between 10 and 40 years were evaluated by means of two complementary classification systems: a five-stage system and a sub-staging system for the main stages 2 and 3. Assessment was possible in 493 cases. The results for stages 4 and 5 are in line with previous studies that found the ages of 21 years and 26 years, respectively, as minimum ages for these stages. Sub-stage 3c was first found at the age of 19 years in both sexes, thereby corroborating the value of this sub-stage as to statements about the age of majority. In comparison to other CT studies, stage 3a was first observed ~1 year earlier (16.4 years in males and 15.5 years in females). Stage 2c only occurred in 3 cases. In conclusion, the data corroborate the significance of diagnosing sub-stages as well as the value of thin-slice CT. For forensic practice, the concomitant and complementary use of both classification systems applied in this study can be recommended.

  15. High-intensity interval training prevents oxidant-mediated diaphragm muscle weakness in hypertensive mice.

    Science.gov (United States)

    Bowen, T Scott; Eisenkolb, Sophia; Drobner, Juliane; Fischer, Tina; Werner, Sarah; Linke, Axel; Mangner, Norman; Schuler, Gerhard; Adams, Volker

    2017-01-01

    Hypertension is a key risk factor for heart failure, with the latter characterized by diaphragm muscle weakness that is mediated in part by increased oxidative stress. In the present study, we used a deoxycorticosterone acetate (DOCA)-salt mouse model to determine whether hypertension could independently induce diaphragm dysfunction and further investigated the effects of high-intensity interval training (HIIT). Sham-treated (n = 11), DOCA-salt-treated (n = 11), and DOCA-salt+HIIT-treated (n = 15) mice were studied over 4 wk. Diaphragm contractile function, protein expression, enzyme activity, and fiber cross-sectional area and type were subsequently determined. Elevated blood pressure confirmed hypertension in DOCA-salt mice independent of HIIT (P HIIT. Myosin heavy chain (MyHC) protein expression tended to decrease (∼30%; P = 0.06) in DOCA-salt vs. sham- and DOCA-salt+HIIT mice, whereas oxidative stress increased (P HIIT further prevented direct oxidant-mediated diaphragm contractile dysfunction (P hypertension induces diaphragm contractile dysfunction via an oxidant-mediated mechanism that is prevented by HIIT.-Bowen, T. S., Eisenkolb, S., Drobner, J., Fischer, T., Werner, S., Linke, A., Mangner, N., Schuler, G., Adams, V. High-intensity interval training prevents oxidant-mediated diaphragm muscle weakness in hypertensive mice. © FASEB.

  16. Thin-layer and paper chromatography

    International Nuclear Information System (INIS)

    Sherma, J.

    1986-01-01

    This selective review covers the literature of thin-layer chromatography (TLC) and paper chromatography (PC) cited in Chemical Abstracts from December 5, 1983, through November 25, 1985, and Analytical Abstracts from November 1983 to November 1985. Also researched directly were the following important journals publishing papers on TLC and PC: the Journal of Chromatography (including its bibliography issues), Journal of High Resolution Chromatography and Chromatography Communications, Journal of Chromatographic Science, Chromatographia, Analytical Chemistry, JAOAC, and the special TLC issues of the Journal of Liquid Chromatography. Many of the inherent advantages of TLC that are obvious to workers familiar with high performance, quantitative theory and practice still are not appreciated adequately by the majority of people using chromatography. These include unrestricted access to the separation process; introducing magnetic, thermal, electrical, and other physical forces to improve resolution; high sample throughput; truly multidimensional separations; and the use of controlled multiple gradients. Many advantages of TLC relative to column chromatography were discussed in the Introductions to our 1982 and 1984 reviews of TLC in this Journal. No complete commercial robotics system specifically for TLC has been developed, but all necessary modules are available for such a system. The combination of robotics, with the continued development of theory, practice, and instrumentation will lead eventually to TLC systems that are unrivaled for speed, versatility, accuracy, precision, and sensitivity. 573 references

  17. Diaphragm Muscle Fiber Weakness and Ubiquitin-Proteasome Activation in Critically Ill Patients

    NARCIS (Netherlands)

    Hooijman, P.E.; Beishuizen, A.; Witt, C.C.; de Waard, M.C.; Girbes, A.R.J.; Spoelstra-de Man, A.M.E.; Niessen, H.W.; Manders, E.; van Hees, H.W.H.; van den Brom, C.E.; Silderhuis, V.; Lawlor, M.W.; Labeit, S.; Stienen, G.J.M.; Hartemink, K.J.; Paul, M.A.; Heunks, L.M.A.; Ottenheijm, C.A.C.

    2015-01-01

    RATIONALE: The clinical significance of diaphragm weakness in critically ill patients is evident: it prolongs ventilator dependency, and increases morbidity and duration of hospital stay. To date, the nature of diaphragm weakness and its underlying pathophysiologic mechanisms are poorly understood.

  18. An attenuation correction method for PET/CT images

    International Nuclear Information System (INIS)

    Ue, Hidenori; Yamazaki, Tomohiro; Haneishi, Hideaki

    2006-01-01

    In PET/CT systems, accurate attenuation correction can be achieved by creating an attenuation map from an X-ray CT image. On the other hand, respiratory-gated PET acquisition is an effective method for avoiding motion blurring of the thoracic and abdominal organs caused by respiratory motion. In PET/CT systems employing respiratory-gated PET, using an X-ray CT image acquired during breath-holding for attenuation correction may have a large effect on the voxel values, especially in regions with substantial respiratory motion. In this report, we propose an attenuation correction method in which, as the first step, a set of respiratory-gated PET images is reconstructed without attenuation correction, as the second step, the motion of each phase PET image from the PET image in the same phase as the CT acquisition timing is estimated by the previously proposed method, as the third step, the CT image corresponding to each respiratory phase is generated from the original CT image by deformation according to the motion vector maps, and as the final step, attenuation correction using these CT images and reconstruction are performed. The effectiveness of the proposed method was evaluated using 4D-NCAT phantoms, and good stability of the voxel values near the diaphragm was observed. (author)

  19. Clinical study of ultrasound-guided percutaneous radiofrequency ablation for primary hepatic carcinoma adjacent to the diaphragm

    Directory of Open Access Journals (Sweden)

    LI Meng

    2015-04-01

    Full Text Available ObjectiveTo investigate the safety and efficacy of ultrasound (US-guided percutaneous radiofrequency ablation (RFA for primary hepatic carcinoma adjacent to the diaphragm. MethodsThis study included 277 patients with 362 lesions of primary hepatic carcinoma managed with US-guided percutaneous RFA in 302 Hospital of PLA from January 2011 to October 2014. Sixty-six patients with 71 hepatocellular carcinomas (HCCs located less than 5 mm from the diaphragm were in study group, and 95 patients with 114 HCCs located more than 10 mm from the hepatic surface were in control group. The patients′ symptoms and complications were observed after the therapy. The complete ablation rate, local tumor progression rate, and complication rate were compared between the two groups. Comparison of continuous data between the two groups was made by independent-samples t test, while comparison of categorical data was made by chi-square test. ResultsAt one month after operation, 65 (91.5% of 71 tumors in the study group and 107 (93.9% of 114 tumors in the control group achieved complete ablation, according to contrast-enhanced CT and MRI, and there was no significant difference between the two groups (χ2=0.36, P=0.55. The postoperative follow-up showed that the local tumor progression rates in the study group and control group were 16.9% and 13.2%, respectively, without significant difference between the two groups (χ2=0.49, P=0.48. In the study group, 22 patients developed adverse reactions, versus 37 patients in the control group (χ2=2.60, P=0.11. ConclusionUS-guided percutaneous RFA is a safe and effective means for the treatment of primary hepatic carcinoma adjacent to the diaphragm.

  20. Percutaneous Radiofrequency Ablation for the Hepatocellular Carcinoma Abutting the Diaphragm: Assessment of Safety and Therapeutic Efficacy

    International Nuclear Information System (INIS)

    Kang, Tae Wook; Rhim, Hyun Chul; Kim, Eun Young; Kim, Young Sun; Choi, Dong Il; Lee, Won Jae; Lim, Hyo K.

    2009-01-01

    To assess the safety and therapeutic efficacy of a percutaneous radiofrequency (RF) ablation for the hepatocellular carcinoma (HCC) abutting the diaphragm. We retrospectively assessed 80 patients who underwent a percutaneous RF ablation for a single nodular (< 4 cm) HCC over the last four years. Each patient underwent an ultrasound-guided RF ablation using internally cooled electrodes for the first-line treatment. We divided patients into two subgroups based on whether the index tumor was abutting (less than 5 mm) the diaphragm or not: group A (abutting; n = 31) versus group B (non-abutting; n = 49). We compared the two subgroups for complications and therapeutic efficacy using image and the review of medical records. The statistical assessment included an independent t-test, Fisher's exact test, and chi-square test. The assessment of the diaphragmatic swelling at CT immediately following the procedure was more severe in group A than group B (mean thickness change:1.44 vs. 0.46 mm, p = 0.00). Further, right shoulder pain was more common in group A than B (p = 0.01). Although minor complications (hemothorax 1 case, pleural effusion 1 case) were noted only in group A, no major thoracic complication occurred in either group. The technical success rate was lower in group A than group B (84% vs. 98%, p = 0.03). As well, the primary and secondary technique effectiveness rates in group A and group B were 90% versus 98% (p = 0.29) and 79% versus 91% (p = 0.25), respectively. The local tumor progression rate was higher in group A than in group B (29% vs. 6%, p = 0.02). We found that the percutaneous RF ablation for the HCC abutting the diaphragm is a safe procedure without major complications. However, it is less effective with regard to technical success and local tumor control

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... sometimes compared to looking into a loaf of bread by cutting the loaf into thin slices. When ... actual CT scanning is performed. Depending on the type of CT scan, the machine may make several ...

  2. Emergencies in the retroperitoneum: assessment of spread of disease by helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Scialpi, M. E-mail: michelescialpi@libero.it; Scaglione, M.; Angelelli, G.; Lupattelli, L.; Resta, M.C.; Resta, M.; Rotondo, A

    2004-04-01

    Acute pancreatitis, leaking abdominal aortic aneurysm, and renal trauma frequently occur in the setting of patients with abdominal nontraumatic and traumatic injury; it represents the most urgent conditions that may determine the presence of fluid collections or haematoma in the retroperitoneum. Single spiral CT and multidetector-row CT (MDCT) play an important role in diagnosis of retroperitoneal emergencies, providing useful informations on the type, site, extent and management of the fluid collections. An accurate CT assessment requires the awareness of the existence of dissectable retroperitoneal fascial planes. Fluid collections or haematoma tends to escape the retroperitoneal site of origin into planes extend from the diaphragm to the pelvic floor. We assess the multicompartimental anatomy of the retroperitoneum and the pathway of spread of the most frequent retroperitoneal fluid collections or haematoma by helical CT.

  3. Right Diaphragm Spontaneous Rupture: A Surgical Approach

    Directory of Open Access Journals (Sweden)

    Duilio Divisi

    2011-01-01

    Full Text Available We present a case of spontaneous rupture of the diaphragm, characterized by nonspecific symptoms. The rapid diagnosis and appropriate surgical approach led to a positive resolution of the pathology.

  4. Free radicals in hypoxic rat diaphragm contractility: no role for xanthine oxidase.

    NARCIS (Netherlands)

    Heunks, L.M.A.; Machiels, H.A.; Abreu, R.A. de; Zhu, X.; Heijden, E. van der; Dekhuijzen, P.N.R.

    2001-01-01

    Recent evidence indicates that hypoxia enhances the generation of oxidants. Little is known about the role of free radicals in contractility of the rat diaphragm during hypoxia. We hypothesized that antioxidants improve contractility of the hypoxic rat diaphragm and that xanthine oxidase (XO) is an

  5. Effects of cartap on isolated mouse phrenic nerve diaphragm and its related mechanism.

    Science.gov (United States)

    Liao, J W; Kang, J J; Liu, S H; Jeng, C R; Cheng, Y W; Hu, C M; Tsai, S F; Wang, S C; Pang, V F

    2000-06-01

    Cartap, a nereistoxin analogue pesticide, is reported to have no irritation to eyes in rabbits. However, we have demonstrated recently that cartap could actually cause acute death in rabbits via ocular exposure. Our preliminary study with isolated mouse phrenic nerve diaphragms has shown that instead of neuromuscular blockade, cartap caused muscular contracture. The objective of the study was to examine the effect of cartap on the neuromuscular junction in more detail and to investigate its possible underlying mechanism with isolated mouse phrenic nerve diaphragms and sarcoplasmic reticulum (SR) vesicles. Cartap or nereistoxin at various concentrations was added in the organ bath with isolated mouse phrenic nerve diaphragm and both nerve- and muscle-evoked twitches were recorded. Instead of blocking the neuromuscular transmission as nereistoxin did, cartap caused contracture in stimulated or quiescent isolated mouse phrenic nerve diaphragm. Both the cartap-induced muscular contracture force and the time interval to initiate the contracture were dose-dependent. The contracture induced by cartap was not affected by the pretreatment of the diaphragm with the acetylcholine receptor blocker alpha-bungarotoxin; the Na(+) channel blocker tetrodotoxin; or various Ca(2+) channel blockers, NiCl(2), verapamil, and nifedipine. On the contrary, the contracture was significantly inhibited when the diaphragm was pretreated with ryanodine or EGTA containing Ca(2+)-free Krebs solution or in combination. This suggested that both internal and extracellular Ca(2+) might participate in cartap-induced skeletal muscle contracture. Moreover, cartap inhibited the [(3)H]-ryanodine binding to the Ca(2+) release channel of SR in a dose-dependent manner. Additionally, cartap could induce a significant reduction in Ca(2+)-ATPase activity of SR vesicles at a relatively high dose. The results suggested that cartap might cause the influx of extracellular Ca(2+) and the release of internal Ca(2

  6. CT diagnosis of concealed rupture of intestine following abdominal trauma

    International Nuclear Information System (INIS)

    Ji Jiansong; Wei Tiemin; Wang Zufei; Zhao Zhongwei; Tu Jianfei; Fan Xiaoxi; Xu Min

    2009-01-01

    Objective: To investigate CT findings of concealed rupture of intestine following abdominal trauma. Methods: CT findings of 11 cases with concealed rupture of intestine following abdominal trauma proved by surgery were identified retrospectively. Results: The main special signs included: (1) Free air in 4 cases, mainly around injured small bowel or under the diaphragm, or in the retroperitoneal space or and in the lump. (2) High density hematoma between the intestines or in the bowel wall (4 cases). (3) Bowel wall injury sign, demonstrated as low density of the injured intestinal wall, attenuated locally but relatively enhanced in neighbor wall on enhanced CT. (4) Lump around the injured bowel wall with obvious ring-shaped enhancement (4 cases). Other signs included: (1) Free fluid in the abdominal cavity or between the intestines with blurred borders. (2) Bowel obstruction. Conclusion: CT is valuable in diagnosing concealed rupture of intestine following abdominal trauma. (authors)

  7. Design of calandria-end shield support diaphragm of Narora Atomic Power Project

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, S K; Nanda Kumar, S; Kakodkar, A

    1975-01-01

    The calandria-end shield diaphragm is one of the important components in Narora Atomic Power Plant. The support diaphragm is designed against elastic and plastic instability failures. Method of analysis for elastic and plastic instability is discussed for normal loading, pipe rupture loading, and earthquake loading.

  8. Design of calandria-end shield support diaphragm of Narora Atomic Power Project

    International Nuclear Information System (INIS)

    Srivastava, S.K.; Nanda Kumar, S.; Kakodkar, A.

    1975-01-01

    The calandria-end shield diaphragm is one of the important components in Narora Atomic Power Plant. The support diaphragm is designed against elastic and plastic instability failures. Method of analysis for elastic and plastic instability is discussed for normal loading, pipe rupture loading and earthquake loading. (author)

  9. A modified SILCS contraceptive diaphragm for long-term controlled release of the HIV microbicide dapivirine.

    Science.gov (United States)

    Major, Ian; Boyd, Peter; Kilbourne-Brook, Maggie; Saxon, Gene; Cohen, Jessica; Malcolm, R Karl

    2013-07-01

    There is considerable interest in developing new multipurpose prevention technologies to address women's reproductive health needs. This study describes an innovative barrier contraceptive device--based on the SILCS diaphragm--that also provides long-term controlled release of the lead candidate anti-HIV microbicide dapivirine. Diaphragm devices comprising various dapivirine-loaded polymer spring cores overmolded with a nonmedicated silicone elastomer sheath were fabricated by injection molding processes. In vitro release testing, thermal analysis and mechanical characterization were performed on the devices. A diaphragm device containing a polyoxymethylene spring core loaded with 10% w/w dapivirine provided continuous and controlled release of dapivirine over a 6-month period, with a mean in vitro daily release rate of 174 mcg/day. The mechanical properties of the new diaphragm were closely matched to the SILCS diaphragm. The study demonstrates proof of concept for a dapivirine-releasing diaphragm with daily release quantities potentially capable of preventing HIV transmission. In discontinuous clinical use, release of dapivirine may be readily extended over 1 or more years. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  11. Dexmedetomidine May Produce Extra Protective Effects on Sepsis-induced Diaphragm Injury

    Directory of Open Access Journals (Sweden)

    Jin Wu

    2015-01-01

    Full Text Available Objective: The objective was to evaluate the protective effects of dexmedetomidine (DEX, a selective agonist of α2-adrenergic receptor, on sepsis-induced diaphragm injury and the underlying molecular mechanisms. Data Sources: The data used in this review were mainly from PubMed articles published in English from 1990 to 2015. Study Selection: Clinical or basic research articles were selected mainly according to their level of relevance to this topic. Results: Sepsis could induce severe diaphragm dysfunction and exacerbate respiratory weakness. The mechanism of sepsis-induced diaphragm injury includes the increased inflammatory cytokines and excessive oxidative stress and superfluous production of nitric oxide (NO. DEX can reduce inflammatory cytokines, inhibit nuclear factor-kappaB signaling pathways, suppress the activation of caspase-3, furthermore decrease oxidative stress and inhibit NO synthase. On the basis of these mechanisms, DEX may result in a shorter period of mechanical ventilation in septic patients in clinical practice. Conclusions: Based on this current available evidence, DEX may produce extra protective effects on sepsis-induced diaphragm injury. Further direct evidence and more specific studies are still required to confirm these beneficial effects.

  12. Temperature Compensation Fiber Bragg Grating Pressure Sensor Based on Plane Diaphragm

    Science.gov (United States)

    Liang, Minfu; Fang, Xinqiu; Ning, Yaosheng

    2018-03-01

    Pressure sensors are the essential equipments in the field of pressure measurement. In this work, we propose a temperature compensation fiber Bragg grating (FBG) pressure sensor based on the plane diaphragm. The plane diaphragm and pressure sensitivity FBG (PS FBG) are used as the pressure sensitive components, and the temperature compensation FBG (TC FBG) is used to improve the temperature cross-sensitivity. Mechanical deformation model and deformation characteristics simulation analysis of the diaphragm are presented. The measurement principle and theoretical analysis of the mathematical relationship between the FBG central wavelength shift and pressure of the sensor are introduced. The sensitivity and measure range can be adjusted by utilizing the different materials and sizes of the diaphragm to accommodate different measure environments. The performance experiments are carried out, and the results indicate that the pressure sensitivity of the sensor is 35.7 pm/MPa in a range from 0 MPa to 50 MPa and has good linearity with a linear fitting correlation coefficient of 99.95%. In addition, the sensor has the advantages of low frequency chirp and high stability, which can be used to measure pressure in mining engineering, civil engineering, or other complex environment.

  13. Temperature Compensation Fiber Bragg Grating Pressure Sensor Based on Plane Diaphragm

    Science.gov (United States)

    Liang, Minfu; Fang, Xinqiu; Ning, Yaosheng

    2018-06-01

    Pressure sensors are the essential equipments in the field of pressure measurement. In this work, we propose a temperature compensation fiber Bragg grating (FBG) pressure sensor based on the plane diaphragm. The plane diaphragm and pressure sensitivity FBG (PS FBG) are used as the pressure sensitive components, and the temperature compensation FBG (TC FBG) is used to improve the temperature cross-sensitivity. Mechanical deformation model and deformation characteristics simulation analysis of the diaphragm are presented. The measurement principle and theoretical analysis of the mathematical relationship between the FBG central wavelength shift and pressure of the sensor are introduced. The sensitivity and measure range can be adjusted by utilizing the different materials and sizes of the diaphragm to accommodate different measure environments. The performance experiments are carried out, and the results indicate that the pressure sensitivity of the sensor is 35.7 pm/MPa in a range from 0 MPa to 50 MPa and has good linearity with a linear fitting correlation coefficient of 99.95%. In addition, the sensor has the advantages of low frequency chirp and high stability, which can be used to measure pressure in mining engineering, civil engineering, or other complex environment.

  14. Convergence of pattern generator outputs on a common mechanism of diaphragm motor unit recruitment.

    Science.gov (United States)

    Mantilla, Carlos B; Seven, Yasin B; Sieck, Gary C

    2014-01-01

    Motor units are the final element of neuromotor control. In manner analogous to the organization of neuromotor control in other skeletal muscles, diaphragm motor units comprise phrenic motoneurons located in the cervical spinal cord that innervate the diaphragm muscle, the main inspiratory muscle in mammals. Diaphragm motor units play a primary role in sustaining ventilation but are also active in other nonventilatory behaviors, including coughing, sneezing, vomiting, defecation, and parturition. Diaphragm muscle fibers comprise all fiber types. Thus, diaphragm motor units display substantial differences in contractile and fatigue properties, but importantly, properties of the motoneuron and muscle fibers within a motor unit are matched. As in other skeletal muscles, diaphragm motor units are recruited in order such that motor units that display greater fatigue resistance are recruited earlier and more often than more fatigable motor units. The properties of the motor unit population are critical determinants of the function of a skeletal muscle across the range of possible motor tasks. Accordingly, fatigue-resistant motor units are sufficient to generate the forces necessary for ventilatory behaviors, whereas more fatigable units are only activated during expulsive behaviors important for airway clearance. Neuromotor control of diaphragm motor units may reflect selective inputs from distinct pattern generators distributed according to the motor unit properties necessary to accomplish these different motor tasks. In contrast, widely distributed inputs to phrenic motoneurons from various pattern generators (e.g., for breathing, coughing, or vocalization) would dictate recruitment order based on intrinsic electrophysiological properties. © 2014 Elsevier B.V. All rights reserved.

  15. Diffusivity measurements in some organic solvents by a gas-liquid diaphragm cell

    NARCIS (Netherlands)

    Littel, R.J.; Littel, R.J.; Versteeg, Geert; van Swaaij, Willibrordus Petrus Maria

    1992-01-01

    A diaphragm cell has been developed for the measurement of diffusion coefficients of gases In liquids. The diaphragm cell is operated batchwise with respect to both gas and liquid phases, and the diffusion process Is followed by means of the gas pressure decrease which is recorded by means of a

  16. Diffusivity Measurements in Some Organic Solvents by a Gas-Liquid Diaphragm Cell

    NARCIS (Netherlands)

    Littel, Rob J.; Versteeg, Geert F.; Swaaij, Wim P.M. van

    1992-01-01

    A diaphragm cell has been developed for the measurement of diffusion coefficients of gases in liquids. The diaphragm cell is operated batchwise with respect to both gas and liquid phases, and the diffusion process is followed by means of the gas pressure decrease which is recorded by means of a

  17. First reported experience with intramuscular diaphragm pacing in replacing positive pressure mechanical ventilators in children.

    Science.gov (United States)

    Onders, Raymond P; Ponsky, Todd A; Elmo, MaryJo; Lidsky, Karen; Barksdale, Edward

    2011-01-01

    Diaphragm pacing (DP) has been shown to successfully replace mechanical ventilators for adult tetraplegic patients with chronic respiratory insufficiency. This is the first report of DP in ventilator-dependent children. This was a prospective interventional experience under institutional review board approval. Diaphragm pacing involves outpatient laparoscopic diaphragm motor point mapping to identify the site where stimulation causes maximum diaphragm contraction with implantation of 4 percutaneous intramuscular electrodes. Diaphragm conditioning ensues to wean the child from the ventilator. Six children were successfully implanted ranging from 5 to 17 years old with the smallest 15 kg in weight. Length of time on mechanical ventilation ranged from 11 days to 7.6 years with an average of 3.2 years. In all patients, DP provided tidal volumes above basal needs. Five of the patients underwent a home-based weaning program, whereas one patient who was implanted only 11 days post spinal cord injury never returned to the ventilator with DP use. Another patient was weaned from the ventilator full time but died of complications of his underlying brain stem tumor. The remaining patients weaned from the ventilator for over 14 hours a day and/or are actively conditioning their diaphragms. Diaphragm pacing successfully replaced mechanical ventilators, which improves quality of life. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Budd-Chiari syndrome: dynamic enhancement findings with multi-slice helical CT and CT angiography analysis

    International Nuclear Information System (INIS)

    Meng Xiaochun; Shan Hong; Zhu Kangshun; Xu Chuan; Zhang Jiansheng; Liu Lingyun; Ye Binbin

    2005-01-01

    Objective: To investigate the dynamic enhancement regulations of liver and their mechanism in Budd-Chiari syndrome (BCS) by using multi-slice CT and evaluate the value of CT angiography in the diagnosis of BCS. Methods: 28 cases with BCS confirmed by digital subtraction angiography (DSA) were retrospectively analyzed. All patients underwent dynamic enhancement examinations with multi-slice CT within 1 week before DSA. The relevant vessels were reconstructed respectively with MIP, VR and MPR. Compared with the results of DSA, we analyzed the dynamic enhancement regulations of liver in BCS, estimated the value of dynamic enhancement CT exams and CTA techniques in judging the obstruction level and showing collateral vessels. Results: Of all 28 cases, CT correctly showed the obstruction level in 26 cases, and 2 had incorrect results which proved to be membranous obstruction of the inferior vena cava superior to diaphragm. In 22 cases with hepatic vein obstructions, hepatic parenchyma displayed typical patchy enhancement in 19, atypical patchy enhancement in 3.8 cases among these showed benign nodules. Simultaneously, CT showed stenosis and rigidity of portal vein branches in 20, enlargement of hepatic artery in 14, hepatic collateral vessels in 20 out of 22 cases. In 6 cases with simple obstruction of inferior vena cava, hepatic changes were not found. Collateral circulations in or out of liver corresponded to the obstruction level. Conclusion: Dynamic enhancement examinations with multi-slice CT can correctly reflect the hepatic hemodynamic changes. Transverse images, combined with CTA, can explicitly display the obstruction level of vascular lesions and collateral circulations in BCS. (authors)

  19. Diaphragm Muscle Weakness Following Acute Sustained Hypoxic Stress in the Mouse Is Prevented by Pretreatment with N-Acetyl Cysteine

    Directory of Open Access Journals (Sweden)

    Andrew J. O’Leary

    2018-01-01

    Full Text Available Oxygen deficit (hypoxia is a major feature of cardiorespiratory diseases characterized by diaphragm dysfunction, yet the putative role of hypoxic stress as a driver of diaphragm dysfunction is understudied. We explored the cellular and functional consequences of sustained hypoxic stress in a mouse model. Adult male mice were exposed to 8 hours of normoxia, or hypoxia (FiO2 = 0.10 with or without antioxidant pretreatment (N-acetyl cysteine, 200 mg/kg i.p.. Ventilation and metabolism were measured. Diaphragm muscle contractile function, myofibre size and distribution, gene expression, protein signalling cascades, and oxidative stress (TBARS were determined. Hypoxia caused pronounced diaphragm muscle weakness, unrelated to increased respiratory muscle work. Hypoxia increased diaphragm HIF-1α protein content and activated MAPK, mTOR, Akt, and FoxO3a signalling pathways, largely favouring protein synthesis. Hypoxia increased diaphragm lipid peroxidation, indicative of oxidative stress. FoxO3 and MuRF-1 gene expression were increased. Diaphragm 20S proteasome activity and muscle fibre size and distribution were unaffected by acute hypoxia. Pretreatment with N-acetyl cysteine substantially enhanced cell survival signalling, prevented hypoxia-induced diaphragm oxidative stress, and prevented hypoxia-induced diaphragm dysfunction. Hypoxia is a potent driver of diaphragm weakness, causing myofibre dysfunction without attendant atrophy. N-acetyl cysteine protects the hypoxic diaphragm and may have application as a potential adjunctive therapy.

  20. CT diagnosis of pleural dissemination without pleural effusion in primary lung cancer

    International Nuclear Information System (INIS)

    Murayama, Sadayuki; Murakami, Junji; Yoshimitsu, Kengo; Torii, Yoshikuni; Masuda, Kouji; Ishida, Teruyoshi.

    1996-01-01

    We retrospectively reviewed the CT scans of 25 primary lung cancers with disseminated pleural nodules or minimal malignant pleural effusion that were not recognized preparatively. Special attention was devoted to abutting interlobar fissures, thick major fissures, and disseminated nodules on the chest wall, the diaphragm, and in the interlobar fissures. Among 10 primary tumors abutting interlobar fissures, nine (90%) had at least one of these findings. Among 15 primary lung tumors which did not abut interlobar fissures, four (27%) had at least one of these findings. We conclude that CT is a useful modality for detecting the pleural dissemination of primary lung cancers when primary lung cancers abut interlobar fissures even if no pleural effusion is detectable on CT. (author)

  1. Improving the Performance of Two-Stage Gas Guns By Adding a Diaphragm in the Pump Tube

    Science.gov (United States)

    Bogdanoff, D. W.; Miller, Robert J.

    1995-01-01

    Herein, we study the technique of improving the gun performance by installing a diaphragm in the pump tube of the gun. A CFD study is carried out for the 0.28 in. gun in the Hypervelocity Free Flight Radiation (HFF RAD) range at the NASA Ames Research Center. The normal, full-length pump tube is studied as well as two pump tubes of reduced length (approximately 75% and approximately 33% of the normal length). Significant improvements in performance are calculated to be gained for the reduced length pump tubes upon the addition of the diaphragm. These improvements are identified as reductions in maximum pressures in the pump tube and at the projectile base of approximately 20%, while maintaining the projectile muzzle velocity or as increases in muzzle velocity of approximately 0.5 km/sec while not increasing the maximum pressures in the gun. Also, it is found that both guns with reduced pump tube length (with diaphragms) could maintain the performance of gun with the full length pump tube without diaphragms, whereas the guns with reduced pump tube lengths without diaphragms could not. A five-shot experimental investigation of the pump tube diaphragm technique is carried out for the gun with a pump tube length of 75% normal. The CFD predictions of increased muzzle velocity are borne out by the experimental data. Modest, but useful muzzle velocity increases (2.5 - 6%) are obtained upon the installation of a diaphragm, compared to a benchmark shot without a diaphragm.

  2. Therapeutic effects of diaphragmatic plication for acquired unilateral non-malignant diaphragm paralysis in twenty patients

    Directory of Open Access Journals (Sweden)

    Reza Bagheri

    2013-12-01

    Full Text Available Background: Acquired paralysis of the diaphragm is a condition caused by trauma, surgical injuries, (lung cancer surgery, esophageal surgery, cardiac surgery, thoracic surgery, and is sometimes of an unknown etiology. It can lead to dyspnea and can affect ventilatory function and patients activity. Diaphragmatic plication is a treatment method which decreases inconsistent function of diaphragm. The aim of this study is to evaluate the outcome of diaphragmatic plication in patients with acquired unilateral non-malignant diaphragmatic paralysis. Methods: From 1991 to 2011, 20 patients with acquired unilateral diaphragmatic paralysis who underwent surgery enrolled in our study in Ghaem Hospital Mashhad University of Medical Science. Patients were evaluated in terms of age, sex, BMI, clinical symptoms, dyspnea score (DS, etiology of paralysis, diagnostic methods, respiratory function tests and complication of surgery. Some tests including dyspnea score were carried out again six months after surgery. We evaluated patients with SPSS version 11.5 and Paired t-test or nonparametric equivalent. Results: Twenty patients enrolled in our study. 14 were male and 6 were female. The mean age was 58 years and the average time interval between diagnosis to surgical treatment was 38.3 months. Acquired diaphragmatic paralysis was mostly caused by trauma (in 11 patients and almost occurred on the left side (in 15 patients. Diagnostic methods included chest x-ray, CT scan, ultrasonography and sniff. Test prior to surgery the average FVC was 41.4±7 percent and the average FEV1 was 52.4±6 percent and after surgery they were 80.1±8.6 percent and 74.4±1 percent respectively. The average increase in FEV1 and FVC 63.4±4, 61.1±7.8. Performing surgery also leads to a noticeable improvement in dyspnea score in our study. Conclusion: In patients with acquired unilateral non-malignant diaphragm paralysis diaphragmatic plication is highly recommended due to the

  3. Spiral hydro-CT of the pancreas in the thin-slice method; Hydrospiral-CT des Pankreas in Duennschichttechnik

    Energy Technology Data Exchange (ETDEWEB)

    Richter, G.M. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Simon, C. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)]|[Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Hoffmann, V. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); DeBernardinis, M. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Seelos, R. [Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Senninger, N. [Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Kauffmann, G.W. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)

    1996-05-01

    In an open prospective study, 151 patients with a suspected pancreatic neoplasm based on clinical, laboratory or other imaging data were examined between May 94 and October 95. Our newly developed Hydro-CT methodology included intravenous injection of 40 mg N-butylscopolaminium bromide (Buscopan) for intestinal paralysis, gastric and duodenal wall distension by oral administration of an average of 1.5 l warm tap water, 30 RAO patient positioning, an individualized contrast injection technique as determined beforehand by time-to-peak measurement in the portal vein and thin-slice spiral CT (3 mm increment, 6 mm table feed and 3 mm secondary reconstruction). A detailed evaluation form was used to assess (1) tumor detection rate, (2) differentiation of malignant versus benign disease, (3) differential diagnosis, and (4) accuracy of assessment of resectability by identification of infiltration into adjacent organs and vessel structures relevant for resectability such as splenic, superior mesenteric, portal vein and celiac trunk, superior mesenteric, splenic and hepatic arteries. As the gold standard for positive tumor detection surgery and microscopic diagnosis were used, and for negative tumor detection an event-free survival of 6 months. Almost all examinations were well tolerated. In only 4% was on-site administration of a gastric tube required because of vomiting. In 2% of the patients a slight allergic reaction to be contrast medium was seen. The prevalence of a pancreatic neoplasm was 38%. In tumor detection Hydro-CT reached an overall accuracy of 97.4% with a sensitivity of 100% and a specificity of 95.9%. In the differentiation of benign versus malignant disease Hydro-CT reached an overall accuracy of 89.7% with a sensitivity of 92.5% and a specificity of 83.3%. The prevalence of a pancreatic carcinoma was 24%; 4% other malignant tumors were found (distal common bile duct carcinoma, cystadenocarcinoma). (orig./MG) [Deutsch] Von Mai 1994 bis Oktober 1995 wurden

  4. Quantification of diaphragm mechanics in Pompe disease using dynamic 3D MRI

    DEFF Research Database (Denmark)

    Mogalle, Katja; Perez-Rovira, Adria; Ciet, Pierluigi

    2016-01-01

    BACKGROUND: Diaphragm weakness is the main reason for respiratory dysfunction in patients with Pompe disease, a progressive metabolic myopathy affecting respiratory and limb-girdle muscles. Since respiratory failure is the major cause of death among adult patients, early identification of respira......BACKGROUND: Diaphragm weakness is the main reason for respiratory dysfunction in patients with Pompe disease, a progressive metabolic myopathy affecting respiratory and limb-girdle muscles. Since respiratory failure is the major cause of death among adult patients, early identification...... methodology relies on image registration and lung surface extraction to quantify lung kinematics during breathing. This allows for the extraction of geometry and motion features of the lung that characterize the independent contribution of the diaphragm and the thoracic muscles to the respiratory cycle....... RESULTS: Results in 16 3D+t MRI scans (10 Pompe patients and 6 controls) of a slow expiratory maneuver show that kinematic analysis from dynamic 3D images reveals important additional information about diaphragm mechanics and respiratory muscle involvement when compared to conventional pulmonary function...

  5. Ground-glass nodule on thin-section CT: Differentiation among adenocarcinoma in situ, minimally invasive adenocarcinoma and lepidic predominant invasive adenocarcinoma

    International Nuclear Information System (INIS)

    Lee, Man Ho; Ryu, Dae Shick; Kim, Do Young; Ahn, Jae Hong; Choi, Soo Jung; Gang, Gil Hyeon; Yoo, Dong Gon; Shin, Dong Rock

    2015-01-01

    To investigate different computed tomography (CT) features among adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), and lepidic predominant invasive adenocarcinoma (LPA) that appeared as ground-glass nodules (GGN). We also analyzed different CT findings between Group A (AIS and MIA) and Group B (LPA). We evaluated 19 AIS, 4 MIA, and 9 LPA images that were histologically confirmed and manifested as GGN on thin-section CT scans. CT scans were assessed for lesion characteristics: size, shape, solid portion, internal air density, marginal irregularity and pleural tag. CT findings of Group A and Group B were analyzed using the Kruskal-Wallis test or Fisher's exact test. A significant statistical difference was seen between AIS and LPA for lesion characteristics (p < 0.05). No significant difference was observed between AIS and MIA. Round or polygonal shape with smooth margin was significantly associated with Group A, and complex shape with marginal irregularity was associated with Group B. Group A (AIS and MIA) could be distinguished from Group B (LPA) by smaller lesion size, round or polygonal shape, smaller solid portion and smooth margin

  6. Ground-glass nodule on thin-section CT: Differentiation among adenocarcinoma in situ, minimally invasive adenocarcinoma and lepidic predominant invasive adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Man Ho; Ryu, Dae Shick; Kim, Do Young; Ahn, Jae Hong; Choi, Soo Jung; Gang, Gil Hyeon; Yoo, Dong Gon; Shin, Dong Rock [Gangneung Asan Hospital, College of Medicine, University of Ulsan, Gangneung (Korea, Republic of)

    2015-12-15

    To investigate different computed tomography (CT) features among adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), and lepidic predominant invasive adenocarcinoma (LPA) that appeared as ground-glass nodules (GGN). We also analyzed different CT findings between Group A (AIS and MIA) and Group B (LPA). We evaluated 19 AIS, 4 MIA, and 9 LPA images that were histologically confirmed and manifested as GGN on thin-section CT scans. CT scans were assessed for lesion characteristics: size, shape, solid portion, internal air density, marginal irregularity and pleural tag. CT findings of Group A and Group B were analyzed using the Kruskal-Wallis test or Fisher's exact test. A significant statistical difference was seen between AIS and LPA for lesion characteristics (p < 0.05). No significant difference was observed between AIS and MIA. Round or polygonal shape with smooth margin was significantly associated with Group A, and complex shape with marginal irregularity was associated with Group B. Group A (AIS and MIA) could be distinguished from Group B (LPA) by smaller lesion size, round or polygonal shape, smaller solid portion and smooth margin.

  7. CT features of appendiceal mucocele

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Won Jong; Byun, Jae Young; Jung, Jung Im; Lee, Hae Gyu; Park, Young Ha; Shin, Kyung Sub [Catholic University Medical College, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate the usefulness of CT features of appendiceal mucocele in the diagnosis and evaluation of complications. We retrospectively reviewed CT findings and compared with operative findings in 7 cases of pathologically proven appendiceal mucocele. CT findings such as location and extent of the lesion, tissue density, thickness or calcification of the wall, presence of adjacent inflammatory infiltration, and visualization of normal vermiform appendix were analyzed. Appendiceal mucocele was found as homogeneous low density cystic mass adjacent to the cecum, which has no surrounding inflammatory infiltration except in one case of perforation and one case of intussusception. Mean CT number measured in 4 cases was 21 Hounsfield unit. Thin curvilinear calcifications were noted along the cystic wall in 2 cases. Normal vermiform appendix couldn't be demonstrated in all cases. Appendiceal mucocele is characterized by homogeneously low density and thin walled cystic tumor adjacent to cecum without surrounding inflammatory infiltration, and absence of normal vermiform appendix on CT. Therefore, CT is valuable in preventing operative complications of appendiceal mucocele.

  8. Sagittal-lung CT measurements in the evaluation of asthma-COPD overlap syndrome: a distinctive phenotype from COPD alone.

    Science.gov (United States)

    Qu, Yanjuan; Cao, Yiyuan; Liao, Meiyan; Lu, Zhiyan

    2017-07-01

    This study aimed at investigating the capability of sagittal-lung computed tomography (CT) measurements in differentiating chronic obstructive pulmonary disease (COPD) and asthma-COPD overlap syndrome (ACOS). Clinical and high-resolution CT of 229 patients including 123 pure COPD patients and 106 ACOS patients were included. Sagittal-lung CT measurements in terms of bilateral lung height (LH), anterior-posterior lung diameter (APLD), diaphragm height (DH), and anterior sterno-diaphragmatic angle (ASDA), as well as inter-pulmonary septum length (IPSL) on axial images were measured both before and after bronchodilator (BD) administration. Comparisons of clinical characteristics and CT measurements between patient groups were performed. All pre-BD quantitative sagittal features measuring diaphragm flattening and hyperinflation were not significantly different between patients with COPD and patients with ACOS (P values all >0.05). Following BD administration, the ACOS patients exhibited lower left LH, bilateral APLD, and bilateral ASDA, but higher right DH, compared to pure COPD patients (P values all <0.05). Right LH, left DH and IPSL were not significantly different between patient groups. Besides, variations of all sagittal-lung CT measurements were significantly larger in patients with ACOS than in patients with pure COPD (P values all <0.001) and showed high performance in differentiating these two kinds of patient, with diagnostic sensitivities ranging from 76.4 to 97.2%, specificities ranging from 86.2 to 100.0%, and accuracies ranging from 80.9 to 90.7%. Sagittal-lung CT measurements allow for differentiating patients with ACOS from those with pure COPD. The ACOS patients had larger post-BD variations of sagittal-lung CT measurements than patients with pure COPD.

  9. Fabry-Perot Diaphragm Fiber Optic Sensor (DFOS for Acoustic Detection

    Directory of Open Access Journals (Sweden)

    Yan SUN

    2007-10-01

    Full Text Available A diaphragm fiber optic sensor (DFOS solely based on Fabry-Perot multiple beam interference has been designed and fabricated with micro-electric mechanical system (MEMS technology. The silicon diaphragm with an embossed center was designed with an interference gap width kept accurately. The DFOS was verified to be a truly and purely Fabry-Perot device via a critical test. Parallel testing with a Piezoelectric (PZT sensor showed that the DFOS had high sensitivity. The Fabry-Perot DFOS also demonstrated excellent performance in on-line monitoring of Partial Discharge (PD in power transformers.

  10. Thin-section CT imaging that correlates with pulmonary function tests in obstructive airway disease

    Energy Technology Data Exchange (ETDEWEB)

    Arakawa, Hiroaki, E-mail: arakawa@dokkyomed.ac.jp [Department of Radiology, Dokkyo Medical University, 880 Kita-Kobayashi, Mibu, Tochigi 321-0293 (Japan); Fujimoto, Kiminori [Department of Radiology, Kurume University School of Medicine (Japan); Fukushima, Yasutugu [Department of Pulmonary Medicine and Clinical Immunology, Dokkyo Medical University (Japan); Kaji, Yasushi [Department of Radiology, Dokkyo Medical University, 880 Kita-Kobayashi, Mibu, Tochigi 321-0293 (Japan)

    2011-11-15

    Purpose: The purpose of this study was to identify independent CT findings that correlated with pulmonary function tests (PFTs) in patients with obstructive airway diseases. Materials and methods: Sixty-eight patients with obstructive airway disease and 29 normal subjects (mean age, 52 years; 36 men and 61 women) underwent inspiratory and expiratory thin-section CT and PFTs. Patient with obvious emphysema was excluded. Two radiologists independently reviewed the images and semi-quantitatively evaluated lung attenuation (mosaic perfusion, air trapping) and airway abnormalities (extent and severity of bronchial wall thickening and bronchiectasis, bronchiolectasis or centrilobular nodules, mucous plugging). Univariate, multivariate and receiver operating characteristic (ROC) analyses were performed with CT findings and PFTs. Results: Forty-two patients showed obstructive PFTs, 26 symptomatic patients showed near-normal PFTs. On univariate analysis, air trapping and bronchial wall thickening showed highest correlation with obstructive PFTs such as FEV1.0/FVC, MMEF and FEF75 (r ranged from -0.712 to -0.782; p < 0.001), while mosaic perfusion and mucous plugging showed moderate correlation, and bronchiectasis, bronchiolectasis and nodules showed the least, but significant, correlation. Multiple logistic analyses revealed air trapping and bronchial wall thickening as the only significant independent determinants of obstructive PFTs. ROC analysis revealed the cut-off value of air trapping for obstructive PFTs to be one-third of whole lung (area under curve, 0.847). Conclusions: Our study confirmed air trapping and bronchial wall thickening are the most important observations when imaging obstructive PFTs. The cut-off value of air trapping for identifying obstructive PFTs was one-third of lung irrespective of inspiratory CT findings.

  11. Diaphragm atrophy and weakness in the absence of mitochondrial dysfunction in the critically Ill

    NARCIS (Netherlands)

    Van den Berg, Marloes; Hooijman, Pleuni E.; Beishuizen, Albertus; De Waard, Monique C.; Paul, Marinus A.; Hartemink, Koen J.; Van Hees, Hieronymus W.H.; Lawlor, Michael W.; Brocca, Lorenza; Bottinelli, Roberto; Pellegrino, Maria A.; Stienen, Ger J.M.; Heunks, Leo M.A.; Wüst, Rob C.I.; Ottenheijm, Coen A.C.

    2017-01-01

    Rationale: The clinical significance of diaphragm weakness in critically ill patients is evident: it prolongs ventilator dependency and increases morbidity, duration of hospital stay, and health care costs. The mechanisms underlying diaphragm weakness are unknown, but might include mitochondrial

  12. Distinct functions of Crumbs regulating slit diaphragms and endocytosis in Drosophila nephrocytes.

    Science.gov (United States)

    Hochapfel, Florian; Denk, Lucia; Mendl, Gudrun; Schulze, Ulf; Maaßen, Christine; Zaytseva, Yulia; Pavenstädt, Hermann; Weide, Thomas; Rachel, Reinhard; Witzgall, Ralph; Krahn, Michael P

    2017-12-01

    Mammalian podocytes, the key determinants of the kidney's filtration barrier, differentiate from columnar epithelial cells and several key determinants of apical-basal polarity in the conventional epithelia have been shown to regulate podocyte morphogenesis and function. However, little is known about the role of Crumbs, a conserved polarity regulator in many epithelia, for slit-diaphragm formation and podocyte function. In this study, we used Drosophila nephrocytes as model system for mammalian podocytes and identified a conserved function of Crumbs proteins for cellular morphogenesis, nephrocyte diaphragm assembly/maintenance, and endocytosis. Nephrocyte-specific knock-down of Crumbs results in disturbed nephrocyte diaphragm assembly/maintenance and decreased endocytosis, which can be rescued by Drosophila Crumbs as well as human Crumbs2 and Crumbs3, which were both expressed in human podocytes. In contrast to the extracellular domain, which facilitates nephrocyte diaphragm assembly/maintenance, the intracellular FERM-interaction motif of Crumbs is essential for regulating endocytosis. Moreover, Moesin, which binds to the FERM-binding domain of Crumbs, is essential for efficient endocytosis. Thus, we describe here a new mechanism of nephrocyte development and function, which is likely to be conserved in mammalian podocytes.

  13. Thin-section spiral CT evaluation of morphologic effects of aging lung in asymptomatic adult subjects

    International Nuclear Information System (INIS)

    Li Kuncheng; Liu Jian; Yang Yanhui; Yao Xinyu; Yin Jianguo; Wang Shiwen; He Zuoxiang

    2006-01-01

    Objective: To evaluate the imaging signs of aging lung in asymptomatic adult subjects by using thin-section spiral CT, and analyze the correlation between the signs and the age of examined cases, as well as probe their clinical application value. Methods: One hundred and six healthy adult subjects were divided into 3 groups: 30 to 44 years (n=31), 45 to 59 years (n=30), and over 60 years (n=45), and all the subjects underwent thin-section spiral CT scans in the upper lung field, the middle lung field and the lower lung field. The evaluation indices included the lung interstitium changes, emphysematous changes, mosaic perfusion, dependent density difference, and pleural thickenning. According to the relative score standard, the above-mentioned indices were totally calculated and converted into the score value. The data were statistically processed with SPSS for Windows. Results: Among the three groups, there were remarkable differences in the indices including the lung interstitium changes, emphysematous changes, and mosaic perfusion, respectively (χ 2 =8.10, 9.73, 15.54, P 2 =3.66, 3.24, P> 0.05). The score values had a significant positive correlation with the age (r=0.709, P<0.01). Conclusion: The signs including the lung interstitium changes, emphysematous changes, mosaic perfusion, the dependent density difference, and pleural thickenning can be found in asymptomatic subjects, and they become prominent as the age increases. HRCT is one of the most important methods for evaluating the early signs of the senile lung. (authors)

  14. Automated method for relating regional pulmonary structure and function: integration of dynamic multislice CT and thin-slice high-resolution CT

    Science.gov (United States)

    Tajik, Jehangir K.; Kugelmass, Steven D.; Hoffman, Eric A.

    1993-07-01

    We have developed a method utilizing x-ray CT for relating pulmonary perfusion to global and regional anatomy, allowing for detailed study of structure to function relationships. A thick slice, high temporal resolution mode is used to follow a bolus contrast agent for blood flow evaluation and is fused with a high spatial resolution, thin slice mode to obtain structure- function detail. To aid analysis of blood flow, we have developed a software module, for our image analysis package (VIDA), to produce the combined structure-function image. Color coded images representing blood flow, mean transit time, regional tissue content, regional blood volume, regional air content, etc. are generated and imbedded in the high resolution volume image. A text file containing these values along with a voxel's 3-D coordinates is also generated. User input can be minimized to identifying the location of the pulmonary artery from which the input function to a blood flow model is derived. Any flow model utilizing one input and one output function can be easily added to a user selectable list. We present examples from our physiologic based research findings to demonstrate the strengths of combining dynamic CT and HRCT relative to other scanning modalities to uniquely characterize pulmonary normal and pathophysiology.

  15. Depletion of Pax7+ satellite cells does not affect diaphragm adaptations to running in young or aged mice.

    Science.gov (United States)

    Murach, Kevin A; Confides, Amy L; Ho, Angel; Jackson, Janna R; Ghazala, Lina S; Peterson, Charlotte A; Dupont-Versteegden, Esther E

    2017-10-01

    Satellite cell depletion does not affect diaphragm adaptations to voluntary wheel running in young or aged mice. Satellite cell depletion early in life (4 months of age) has minimal effect on diaphragm phenotype by old age (24 months). Prolonged satellite cell depletion in the diaphragm does not result in excessive extracellular matrix accumulation, in contrast to what has been reported in hind limb muscles. Up-regulation of Pax3 mRNA+ cells after satellite cell depletion in young and aged mice suggests that Pax3+ cells may compensate for a loss of Pax7+ satellite cells in the diaphragm. Future investigations should focus on the role of Pax3+ cells in the diaphragm during adaptation to exercise and ageing. Satellite cell contribution to unstressed diaphragm is higher compared to hind limb muscles, which is probably attributable to constant activation of this muscle to drive ventilation. Whether satellite cell depletion negatively impacts diaphragm quantitative and qualitative characteristics under stressed conditions in young and aged mice is unknown. We therefore challenged the diaphragm with prolonged running activity in the presence and absence of Pax7+ satellite cells in young and aged mice using an inducible Pax7 CreER -R26R DTA model. Mice were vehicle (Veh, satellite cell-replete) or tamoxifen (Tam, satellite cell-depleted) treated at 4 months of age and were then allowed to run voluntarily at 6 months (young) and 22 months (aged). Age-matched, cage-dwelling, Veh- and Tam-treated mice without wheel access served as activity controls. Diaphragm muscles were analysed from young (8 months) and aged (24 months) mice. Satellite cell depletion did not alter diaphragm mean fibre cross-sectional area, fibre type distribution or extracellular matrix content in young or aged mice, regardless of running activity. Resting in vivo diaphragm function was also unaffected by satellite cell depletion. Myonuclear density was maintained in young satellite cell

  16. Robust control of dielectric elastomer diaphragm actuator for human pulse signal tracking

    Science.gov (United States)

    Ye, Zhihang; Chen, Zheng; Asmatulu, Ramazan; Chan, Hoyin

    2017-08-01

    Human pulse signal tracking is an emerging technology that is needed in traditional Chinese medicine. However, soft actuation with multi-frequency tracking capability is needed for tracking human pulse signal. Dielectric elastomer (DE) is one type of soft actuating that has great potential in human pulse signal tracking. In this paper, a DE diaphragm actuator was designed and fabricated to track human pulse pressure signal. A physics-based and control-oriented model has been developed to capture the dynamic behavior of DE diaphragm actuator. Using the physical model, an H-infinity robust control was designed for the actuator to reject high-frequency sensing noises and disturbances. The robust control was then implemented in real-time to track a multi-frequency signal, which verified the tracking capability and robustness of the control system. In the human pulse signal tracking test, a human pulse signal was measured at the City University of Hong Kong and then was tracked using DE actuator at Wichita State University in the US. Experimental results have verified that the DE actuator with its robust control is capable of tracking human pulse signal.

  17. Action of the isolated canine diaphragm on the lower ribs at high lung volumes.

    Science.gov (United States)

    De Troyer, André; Wilson, Theodore A

    2014-10-15

    The normal diaphragm has an inspiratory action on the lower ribs, but subjects with chronic obstructive pulmonary disease commonly have an inward displacement of the lateral portions of the lower rib cage during inspiration. This paradoxical displacement, conventionally called 'Hoover's sign', has traditionally been attributed to the direct action of radially oriented diaphragmatic muscle fibres. In the present study, the inspiratory intercostal muscles in all interspaces in anaesthetized dogs were severed so that the diaphragm was the only muscle active during inspiration. The displacements of the lower ribs along the craniocaudal and laterolateral axes and the changes in pleural pressure (∆Ppl) and transdiaphragmatic pressure were measured during occluded breaths and mechanical ventilation at different lung volumes between functional residual capacity (FRC) and total lung capacity. From these data, the separate effects on rib displacement of ∆Ppl and of the force exerted by the diaphragm on the ribs were determined. Isolated spontaneous diaphragm contraction at FRC displaced the lower ribs cranially and outward, but this motion was progressively reversed into a caudal and inward motion as lung volume increased. However, although the force exerted by the diaphragm on the ribs decreased with increasing volume, it continued to displace the ribs cranially and outward. These observations suggest that Hoover's sign is usually caused by the decrease in the zone of apposition and, thus, by the dominant effect of ∆Ppl on the lower ribs, rather than an inward pull from the diaphragm. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.

  18. Autophagy-associated atrophy and metabolic remodeling of the mouse diaphragm after short-term intermittent hypoxia.

    Directory of Open Access Journals (Sweden)

    Christian Giordano

    Full Text Available Short-term intermittent hypoxia (IH is common in patients with acute respiratory disorders. Although prolonged exposure to hypoxia induces atrophy and increased fatigability of skeletal muscle, the response to short-term IH is less well known. We hypothesized that the diaphragm and limb muscles would adapt differently to short-term IH given that hypoxia stimulates ventilation and triggers a superimposed exercise stimulus in the diaphragm.We determined the structural, metabolic, and contractile properties of the mouse diaphragm after 4 days of IH (8 hours per day, 30 episodes per hour to a FiO2 nadir=6%, and compared responses in the diaphragm to a commonly studied reference limb muscle, the tibialis anterior. Outcome measures included muscle fiber size, assays of muscle proteolysis (calpain, ubiquitin-proteasome, and autophagy pathways, markers of oxidative stress and mitochondrial function, quantification of intramyocellular lipid and lipid metabolism genes, type I myosin heavy chain (MyHC expression, and in vitro contractile properties.After 4 days of IH, the diaphragm alone demonstrated significant atrophy (30% decrease of myofiber size together with increased LC3B-II protein (2.4-fold and mRNA markers of the autophagy pathway (LC3B, Gabarapl1, Bnip3, whereas active calpain and E3 ubiquitin ligases (MuRF1, atrogin-1 were unaffected in both muscles. Succinate dehydrogenase activity was significantly reduced by IH in both muscles. However, only the diaphragm exhibited increased intramyocellular lipid droplets (2.5-fold after IH, along with upregulation of genes linked to activated lipid metabolism. In addition, although the diaphragm showed evidence for acute fatigue immediately following IH, it underwent an adaptive fiber type switch toward slow type I MyHC-expressing fibers, associated with greater intrinsic endurance of the muscle during repetitive stimulation in vitro.Short-term IH induces preferential atrophy in the mouse diaphragm

  19. Effects of acute respiratory and metabolic acidosis on diaphragm muscle obtained from rats.

    Science.gov (United States)

    Michelet, Pierre; Carreira, Serge; Demoule, Alexandre; Amour, Julien; Langeron, Olivier; Riou, Bruno; Coirault, Catherine

    2015-04-01

    Acute respiratory acidosis is associated with alterations in diaphragm performance. The authors compared the effects of respiratory acidosis and metabolic acidosis in the rat diaphragm in vitro. Diaphragmatic strips were stimulated in vitro, and mechanical and energetic variables were measured, cross-bridge kinetics calculated, and the effects of fatigue evaluated. An extracellular pH of 7.00 was obtained by increasing carbon dioxide tension (from 25 to 104 mmHg) in the respiratory acidosis group (n = 12) or lowering bicarbonate concentration (from 24.5 to 5.5 mM) in the metabolic acidosis group (n = 12) and the results compared with a control group (n = 12, pH = 7.40) after 20-min exposure. Respiratory acidosis induced a significant decrease in maximum shortening velocity (-33%, P Respiratory acidosis impaired more relaxation than contraction, as shown by impairment in contraction-relaxation coupling under isotonic (-26%, P acidosis group. In rat diaphragm, acute (20 min) respiratory acidosis induced a marked decrease in the diaphragm contractility, which was not observed in metabolic acidosis.

  20. Phrenic Nerve Reconstruction and Bilateral Diaphragm Plication After Lobectomy.

    Science.gov (United States)

    Shinohara, Shuichi; Yamada, Tetsu; Ueda, Mitsuhiro; Ishinagi, Hiroyoshi; Matsuoka, Takahisa; Nagai, Shinjiro; Matsuoka, Katsunari; Miyamoto, Yoshihiro

    2017-07-01

    A 49-year-old man with left phrenic nerve paralysis caused by mediastinal tumor resection 28 years earlier was found to have a nodule in the right upper lobe. The right phrenic nerve was severed during right upper lobectomy but was reconstructed along with bilateral plication of the diaphragm. The patient was weaned from the ventilator during the daytime on postoperative day 13 and was discharged home on postoperative day 48. Three months postoperatively, chest fluoroscopic imaging showed recovery of movement of the right diaphragm. Nerve conduction studies showed improvement of function of the reconstructed right phrenic nerve. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Bronchus-associated lymphoid tissue (BALT) lymphoma of the lung showing mosaic pattern of inhomogeneous attenuation on thin-section CT: a case report

    International Nuclear Information System (INIS)

    Lee, In Jae; Kim, Sung Hwan; Koo, Soo Hyun; Kim, Hyun Beom; Hwang, Dae Hyun; Lee, Kwan Seop; Lee, Yul; Jang, Kee Taek; Kim, Duck Hwan

    2000-01-01

    The authors present a case of histologically proven bronchus-associated lymphoid tissue (BALT) lymphoma of the lung in a patient with primary Sjogren's syndrome that manifested on thin-section CT scan as a mosaic pattern of inhomogeneous attenuation due to mixed small airway and infiltrative abnormalities

  2. The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging

    International Nuclear Information System (INIS)

    Liu Chi; Pierce II, Larry A; Alessio, Adam M; Kinahan, Paul E

    2009-01-01

    Our aim is to investigate the impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging using a population of patient respiratory traces. A total of 1295 respiratory traces acquired during whole body PET/CT imaging were classified into three types according to the qualitative shape of their signal histograms. Each trace was scaled to three diaphragm motion amplitudes (6 mm, 11 mm and 16 mm) to drive a whole body PET/CT computer simulation that was validated with a physical phantom experiment. Three lung lesions and one liver lesion were simulated with diameters of 1 cm and 2 cm. PET data were reconstructed using the OS-EM algorithm with attenuation correction using CT images at the end-expiration phase and respiratory-averaged CT. The errors of the lesion maximum standardized uptake values (SUV max ) and lesion volumes between motion-free and motion-blurred PET/CT images were measured and analyzed. For respiration with 11 mm diaphragm motion and larger quiescent period fraction, respiratory motion can cause a mean lesion SUV max underestimation of 28% and a mean lesion volume overestimation of 130% in PET/CT images with 1 cm lesions. The errors of lesion SUV max and volume are larger for patient traces with larger motion amplitudes. Smaller lesions are more sensitive to respiratory motion than larger lesions for the same motion amplitude. Patient respiratory traces with relatively larger quiescent period fraction yield results less subject to respiratory motion than traces with long-term amplitude variability. Mismatched attenuation correction due to respiratory motion can cause SUV max overestimation for lesions in the lower lung region close to the liver dome. Using respiratory-averaged CT for attenuation correction yields smaller mismatch errors than those using end-expiration CT. Respiratory motion can have a significant impact on static oncological PET/CT imaging where SUV and/or volume measurements are important. The impact

  3. CT-guided thin needles percutaneous cryoablation (PCA) in patients with primary and secondary lung tumors: A preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Pusceddu, Claudio, E-mail: clapusceddu@gmail.com [Division of Interventional Radiology, Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncologic Diseases, Cagliari, Zip code 09100 (Italy); Sotgia, Barbara, E-mail: barbara.sotgia@gmail.com [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Fele, Rosa Maria, E-mail: rosellafele@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Melis, Luca, E-mail: doclucamelis@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy)

    2013-05-15

    Purpose: To report the data of our initial experience with CT-guided thin cryoprobes for percutaneous cryoablation (PCA) in patients with primary and secondary pulmonary tumors. Material and methods: CT-guided thin needles PCA was performed on 34 lung masses (11 NSCLC = 32%; 23 secondary lung malignancies = 68%) in 32 consecutive patients (24 men and 8 women; mean age 67 ± 10 years) not suitable for surgical resection. Lung masses were treated using two types of cryoprobes: IceRod and IceSeed able to obtain different size of iceball. The number of probes used ranged from 1 to 5 depending on the size of the tumor. After insertion of the cryoprobes into the lesion, the PCA were performed with two 2 (91%) or 3 (9%) cycles each of 12 min of freezing followed by a 4 min active thawing phase and a 4 min passive thawing phase for each one for all treatments. Results: All cryoablation sessions were successfully completed. All primary and metastatic lung tumors were ablated. No procedure-related deaths occurred. Morbidity consisted of 21% (7 of 34) pneumothorax and 3% (1 of 34) cases asymptomatic small pulmonary hemorrhage, respectively, all of CTCAE grade 1 (Common Terminology Criteria for Adverse Events). Low density of entire lesion, central necrosis and solid mass appearance were identify in 21 (62%), 7 (21%) and 6 (17%) of cryoablated tumors, respectively. No lymphadenopathy developed in the region of treated lesions. Technical success (complete lack of enhancement) was achieved in 82%, 97% and 91% of treated lesions at 1-, 3- and 6-months CT follow-up scan, respectively (p < .000). Comparing the tumor longest diameter between the baseline and at 6 month CT images, technical success was revealed in 92% cases (p < .000). Conclusion: Our preliminary experience suggests that PCA is a feasible treatment option. Well-designed clinical trials with a larger patient population are necessary to further investigate the long-term results and prognostic factors.

  4. Documentation of diaphragmal paralysis with digital subtraction techniques

    International Nuclear Information System (INIS)

    Waggershauser, T.; Muenchen Univ.; Buente, E.; Muenchen Univ.; Kohz, P.; Muenchen Univ.; Fink, U.; Muenchen Univ.

    1992-01-01

    The causative factors for a paresis of the diaphragm are primarily subsequent to operations on lesions of the phrenic nerve or on such mediastinal tumors as lyphomas which result in compression or infiltration of the nerves. (orig.) [de

  5. CFD Fuel Slosh Modeling of Fluid-Structure Interaction in Spacecraft Propellant Tanks with Diaphragms

    Science.gov (United States)

    Sances, Dillon J.; Gangadharan, Sathya N.; Sudermann, James E.; Marsell, Brandon

    2010-01-01

    Liquid sloshing within spacecraft propellant tanks causes rapid energy dissipation at resonant modes, which can result in attitude destabilization of the vehicle. Identifying resonant slosh modes currently requires experimental testing and mechanical pendulum analogs to characterize the slosh dynamics. Computational Fluid Dynamics (CFD) techniques have recently been validated as an effective tool for simulating fuel slosh within free-surface propellant tanks. Propellant tanks often incorporate an internal flexible diaphragm to separate ullage and propellant which increases modeling complexity. A coupled fluid-structure CFD model is required to capture the damping effects of a flexible diaphragm on the propellant. ANSYS multidisciplinary engineering software employs a coupled solver for analyzing two-way Fluid Structure Interaction (FSI) cases such as the diaphragm propellant tank system. Slosh models generated by ANSYS software are validated by experimental lateral slosh test results. Accurate data correlation would produce an innovative technique for modeling fuel slosh within diaphragm tanks and provide an accurate and efficient tool for identifying resonant modes and the slosh dynamic response.

  6. Upright 3D Treatment Planning Using a Vertical CT

    International Nuclear Information System (INIS)

    Shah, Anand P.; Strauss, Jonathan B.; Kirk, Michael C.; Chen, Sea S.; Kroc, Thomas K.; Zusag, Thomas W.

    2009-01-01

    In this report, we describe a novel technique used to plan and administer external beam radiation therapy to a patient in the upright position. A patient required reirradiation for thymic carcinoma but was unable to tolerate the supine position due to bilateral phrenic nerve injury and paralysis of the diaphragm. Computed tomography (CT) images in the upright position were acquired at the Northern Illinois University Institute for Neutron Therapy at Fermilab. The CT data were imported into a standard 3-dimensional (3D) treatment planning system. Treatment was designed to deliver 24 Gy to the target volume while respecting normal tissue tolerances. A custom chair that locked into the treatment table indexing system was constructed for immobilization, and port films verified the reproducibility of setup. Radiation was administered using mixed photon and electron AP fields

  7. Global Proteome Changes in the Rat Diaphragm Induced by Endurance Exercise Training.

    Directory of Open Access Journals (Sweden)

    Kurt J Sollanek

    Full Text Available Mechanical ventilation (MV is a life-saving intervention for many critically ill patients. Unfortunately, prolonged MV results in the rapid development of diaphragmatic atrophy and weakness. Importantly, endurance exercise training results in a diaphragmatic phenotype that is protected against ventilator-induced diaphragmatic atrophy and weakness. The mechanisms responsible for this exercise-induced protection against ventilator-induced diaphragmatic atrophy remain unknown. Therefore, to investigate exercise-induced changes in diaphragm muscle proteins, we compared the diaphragmatic proteome from sedentary and exercise-trained rats. Specifically, using label-free liquid chromatography-mass spectrometry, we performed a proteomics analysis of both soluble proteins and mitochondrial proteins isolated from diaphragm muscle. The total number of diaphragm proteins profiled in the soluble protein fraction and mitochondrial protein fraction were 813 and 732, respectively. Endurance exercise training significantly (P<0.05, FDR <10% altered the abundance of 70 proteins in the soluble diaphragm proteome and 25 proteins of the mitochondrial proteome. In particular, key cytoprotective proteins that increased in relative abundance following exercise training included mitochondrial fission process 1 (Mtfp1; MTP18, 3-mercaptopyruvate sulfurtransferase (3MPST, microsomal glutathione S-transferase 3 (Mgst3; GST-III, and heat shock protein 70 kDa protein 1A/1B (HSP70. While these proteins are known to be cytoprotective in several cell types, the cyto-protective roles of these proteins have yet to be fully elucidated in diaphragm muscle fibers. Based upon these important findings, future experiments can now determine which of these diaphragmatic proteins are sufficient and/or required to promote exercise-induced protection against inactivity-induced muscle atrophy.

  8. Comparative study of CT and MR guided cryoablation for hepatic tumors

    International Nuclear Information System (INIS)

    Wu Bin; Xiao Yueyong; Zhang Xiao; Li Hongjun; Li Jie; Yu Da

    2010-01-01

    Objective: To compare CT and MR imaging in guiding and monitor/ng cryoablation of hepatic tumors. Methods: A total of 131 lesions in 121 patients with malignant tumors of liver were treated with imaging-guided percutaneous cryotherapy. There were 73 males and 48 females, mean age 60 years. Of the 121 patients, 61 patients had cryoablation under CT guidance and 60 patients under the guidance of MRI. CT-guidance was performed with the Philips big-bore CT in spiral mode, with 5 mm slice thickness. The MR guidance was performed with GE 0.35 T scanner assisted with infrared navigator (Xinaomdt), and both fast gradient echo sequence and fast spin-echo sequence were used. The cryoablation system is a magnetic resonance compatible system (Galil, Israel), equipped with 17 G cryoprobes that are 1.47 mm in outside diameter. A combination of multiple cryo-probes and conformal cryoablation were adopted in accordance with the location, the shape and the adjacent structure of each lesion. Each cryoablation included two freezing-thawing cycles. Scanning was performed intermittently during the operation to monitor the degree of ablation. The mean scanning time, the lesion depiction and ablation process monitoring, the efficacies of lesion ablation, complications,and survival time were analyzed with χ 2 test. Results: The mean scanning time was (5.6±1.8) min for CT and (22.0±2.6) min for MR. CT provided a good depiction of the lesion and the ribs which were poorly displayed on MR images. The metal probe could create artifacts on the CT images and it was difficult for CT to show the formation of ice ball of the lesion formed after embolization with lipiodol. MR was superior to CT in displaying, guiding and monitoring of ablation of lesions near such special regions as the diaphragm dome, the hepatic hilum, and the gallbladder. MR was not affected by high-density embolization material and the metal probes, and thus was superior to CT in depicting the lesion, and monitoring the

  9. Bronchus-associated lymphoid tissue (BALT) lymphoma of the lung showing mosaic pattern of inhomogeneous attenuation on thin-section CT: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Jae; Kim, Sung Hwan; Koo, Soo Hyun; Kim, Hyun Beom; Hwang, Dae Hyun; Lee, Kwan Seop; Lee, Yul; Jang, Kee Taek; Kim, Duck Hwan [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of)

    2000-09-01

    The authors present a case of histologically proven bronchus-associated lymphoid tissue (BALT) lymphoma of the lung in a patient with primary Sjogren's syndrome that manifested on thin-section CT scan as a mosaic pattern of inhomogeneous attenuation due to mixed small airway and infiltrative abnormalities.

  10. Early development of the human pelvic diaphragm

    NARCIS (Netherlands)

    Koch, Wijnandus Franciscus Robertus Maria

    2006-01-01

    The last decade an increasing interest in the pelvic floor can be observed in medical sciences. The lack of data on the development of the human pelvic floor is striking. The early development of the human pelvic diaphragm was studied. Materials and methodsUse was made of 38 human embryos and

  11. Limitations of CT in the prediction of gallstone composition

    International Nuclear Information System (INIS)

    Brink, J.A.; Mueller, P.R.; Simeone, J.F.; Prien, E.L.; Saini, S.; Tung, G.; Ferrucci, J.T.

    1989-01-01

    Gallstones from 87 patients were harvested at cholecystectomy and selected for thin-section specimen CT and crystallographic analysis. A peripheral rim of density different from the center of the stone was noted in 32 (37%) of 87. The relative attenuations (HU) of the stone rim and stone core were recorded as the difference in attenuation from that of the distilled water bath. The correlation of these measurements with the percent cholesterol content in both the rim and core were poor (r = .57, 0.34, respectively). This paper reports the predictive ability of CT examined by defining predominantly cholesterol stones as having a relative core HV ≥ (62 of 87) and core cholesterol content ≥ 80% (59 of 87). Ct correctly predicted the composition as predominantly cholesterol or pigment in 68 of 87 (78%)

  12. Partial Support Ventilation and Mitochondrial-Targeted Antioxidants Protect against Ventilator-Induced Decreases in Diaphragm Muscle Protein Synthesis.

    Science.gov (United States)

    Hudson, Matthew B; Smuder, Ashley J; Nelson, W Bradley; Wiggs, Michael P; Shimkus, Kevin L; Fluckey, James D; Szeto, Hazel H; Powers, Scott K

    2015-01-01

    Mechanical ventilation (MV) is a life-saving intervention in patients in respiratory failure. Unfortunately, prolonged MV results in the rapid development of diaphragm atrophy and weakness. MV-induced diaphragmatic weakness is significant because inspiratory muscle dysfunction is a risk factor for problematic weaning from MV. Therefore, developing a clinical intervention to prevent MV-induced diaphragm atrophy is important. In this regard, MV-induced diaphragmatic atrophy occurs due to both increased proteolysis and decreased protein synthesis. While efforts to impede MV-induced increased proteolysis in the diaphragm are well-documented, only one study has investigated methods of preserving diaphragmatic protein synthesis during prolonged MV. Therefore, we evaluated the efficacy of two therapeutic interventions that, conceptually, have the potential to sustain protein synthesis in the rat diaphragm during prolonged MV. Specifically, these experiments were designed to: 1) determine if partial-support MV will protect against the decrease in diaphragmatic protein synthesis that occurs during prolonged full-support MV; and 2) establish if treatment with a mitochondrial-targeted antioxidant will maintain diaphragm protein synthesis during full-support MV. Compared to spontaneously breathing animals, full support MV resulted in a significant decline in diaphragmatic protein synthesis during 12 hours of MV. In contrast, diaphragm protein synthesis rates were maintained during partial support MV at levels comparable to spontaneous breathing animals. Further, treatment of animals with a mitochondrial-targeted antioxidant prevented oxidative stress during full support MV and maintained diaphragm protein synthesis at the level of spontaneous breathing animals. We conclude that treatment with mitochondrial-targeted antioxidants or the use of partial-support MV are potential strategies to preserve diaphragm protein synthesis during prolonged MV.

  13. Partial Support Ventilation and Mitochondrial-Targeted Antioxidants Protect against Ventilator-Induced Decreases in Diaphragm Muscle Protein Synthesis.

    Directory of Open Access Journals (Sweden)

    Matthew B Hudson

    Full Text Available Mechanical ventilation (MV is a life-saving intervention in patients in respiratory failure. Unfortunately, prolonged MV results in the rapid development of diaphragm atrophy and weakness. MV-induced diaphragmatic weakness is significant because inspiratory muscle dysfunction is a risk factor for problematic weaning from MV. Therefore, developing a clinical intervention to prevent MV-induced diaphragm atrophy is important. In this regard, MV-induced diaphragmatic atrophy occurs due to both increased proteolysis and decreased protein synthesis. While efforts to impede MV-induced increased proteolysis in the diaphragm are well-documented, only one study has investigated methods of preserving diaphragmatic protein synthesis during prolonged MV. Therefore, we evaluated the efficacy of two therapeutic interventions that, conceptually, have the potential to sustain protein synthesis in the rat diaphragm during prolonged MV. Specifically, these experiments were designed to: 1 determine if partial-support MV will protect against the decrease in diaphragmatic protein synthesis that occurs during prolonged full-support MV; and 2 establish if treatment with a mitochondrial-targeted antioxidant will maintain diaphragm protein synthesis during full-support MV. Compared to spontaneously breathing animals, full support MV resulted in a significant decline in diaphragmatic protein synthesis during 12 hours of MV. In contrast, diaphragm protein synthesis rates were maintained during partial support MV at levels comparable to spontaneous breathing animals. Further, treatment of animals with a mitochondrial-targeted antioxidant prevented oxidative stress during full support MV and maintained diaphragm protein synthesis at the level of spontaneous breathing animals. We conclude that treatment with mitochondrial-targeted antioxidants or the use of partial-support MV are potential strategies to preserve diaphragm protein synthesis during prolonged MV.

  14. Intrinsic respiratory gating in small-animal CT

    International Nuclear Information System (INIS)

    Bartling, Soenke H.; Dinkel, Julien; Kauczor, Hans-Ulrich; Stiller, Wolfram; Semmler, Wolfhard; Grasruck, Michael; Madisch, Ijad; Gupta, Rajiv; Kiessling, Fabian

    2008-01-01

    Gating in small-animal CT imaging can compensate artefacts caused by physiological motion during scanning. However, all published gating approaches for small animals rely on additional hardware to derive the gating signals. In contrast, in this study a novel method of intrinsic respiratory gating of rodents was developed and tested for mice (n=5), rats (n=5) and rabbits (n=2) in a flat-panel cone-beam CT system. In a consensus read image quality was compared with that of non-gated and retrospective extrinsically gated scans performed using a pneumatic cushion. In comparison to non-gated images, image quality improved significantly using intrinsic and extrinsic gating. Delineation of diaphragm and lung structure improved in all animals. Image quality of intrinsically gated CT was judged to be equivalent to extrinsically gated ones. Additionally 4D datasets were calculated using both gating methods. Values for expiratory, inspiratory and tidal lung volumes determined with the two gating methods were comparable and correlated well with values known from the literature. We could show that intrinsic respiratory gating in rodents makes additional gating hardware and preparatory efforts superfluous. This method improves image quality and allows derivation of functional data. Therefore it bears the potential to find wide applications in small-animal CT imaging. (orig.)

  15. Sliding thin slab, minimum intensity projection imaging for objective analysis of emphysema

    International Nuclear Information System (INIS)

    Satoh, Shiro; Ohdama, Shinichi; Shibuya, Hitoshi

    2006-01-01

    The aim of this study was to determine whether sliding thin slab, minimum intensity projection (STS-MinIP) imaging is more advantageous than thin-section computed tomography (CT) for detecting and assessing emphysema. Objective quantification of emphysema by STS-MinIP and thin-section CT was defined as the percentage of area lower than the threshold in the lung section at the level of the aortic arch, tracheal carina, and 5 cm below the carina. Quantitative analysis in 100 subjects was performed and compared with pulmonary function test results. The ratio of the low attenuation area in the lung measured by STS-MinIP was significantly higher than that found by thin-section CT (P<0.01). The difference between STS-MinIP and thin-section CT was statistically evident even for mild emphysema and increased depending on whether the low attenuation in the lung increased. Moreover, STS-MinIP showed a stronger regression relation with pulmonary function results than did thin-section CT (P<0.01). STS-MinIP can be recommended as a new morphometric method for detecting and assessing the severity of emphysema. (author)

  16. WE-G-18C-06: Is Diaphragm Motion a Good Surrogate for Liver Tumor Motion?

    Energy Technology Data Exchange (ETDEWEB)

    Yang, J [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); School of Information Science and Engineering, Shandong University, Jinan, Shandong (China); Cai, J; Zheng, C; Czito, B; Palta, M; Yin, F [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Wang, H [School of Information Science and Engineering, Shandong University, Jinan, Shandong (China); Bashir, M [Department of Radiology, Duke University Medical Center, Durham, NC (United States)

    2014-06-15

    Purpose: To investigate whether diaphragm motion is a good surrogate for liver tumor motion by comparing their motion trajectories obtained from cine-MRI. Methods: Fourteen patients with hepatocellular carcinoma (10/14) or liver metastases (4/14) undergoing radiation therapy were included in this study. All patients underwent single-slice 2D cine-MRI simulations across the center of the tumor in three orthogonal planes. Tumor and diaphragm motion trajectories in the superior-inferior (SI), anteriorposterior (AP), and medial-lateral (ML) directions were obtained using the normalized cross-correlation based tracking technique. Agreement between tumor and diaphragm motions was assessed by calculating the phase difference percentage (PDP), intra-class correlation coefficient (ICC), Bland-Altman analysis (Diffs) and paired t-test. The distance (D) between tumor and tracked diaphragm area was analyzed to understand its impact on the correlation between tumor and diaphragm motions. Results: Of all patients, the means (±standard deviations) of PDP were 7.1 (±1.1)%, 4.5 (±0.5)% and 17.5 (±4.5)% in the SI, AP and ML directions, respectively. The means of ICC were 0.98 (±0.02), 0.97 (±0.02), and 0.08 (±0.06) in the SI, AP and ML directions, respectively. The Diffs were 2.8 (±1.4) mm, 2.4 (±1.1) mm, and 2.2 (±0.5) mm in the SI, AP and ML directions, respectively. The p-values derived from the paired t-test were < 0.02 in SI and AP directions, whereas were > 0.58 in ML direction primarily due to the small motion in ML direction. Tumor and diaphragmatic motion had high concordance when the distance between the tumor and tracked diaphragm areas was small. Conclusion: Preliminary results showed that liver tumor motion had good correlations with diaphragm motion in the SI and AP directions, indicating diaphragm motion in the SI and AP directions could potentially be a reliable surrogate for liver tumor motion. NIH (1R21CA165384-01A1), Golfers Against Cancer (GAC

  17. A new straight accelerator tube with U diaphragm

    International Nuclear Information System (INIS)

    Liu Jinhong; Lai Weiquan; Deng Yushen; Zhang Jidong

    1994-01-01

    After calculating the potential distribution and the particle trajectories in electrostatic accelerator tubes, a new straight tube with U diaphragm to suppress secondary particles is proposed. It's properties are demonstrated by the high voltage tests and the γ-rays measurements in the accelerator

  18. Detection of thin wall regions of unruptured cerebral aneurysms by ECG synchronous reconstruction 3D-CT angiography (4D-CTA) using 16 slices per rotation CT

    International Nuclear Information System (INIS)

    Fujita, Shigekiyo

    2004-01-01

    The objective of this study was to evaluate the capability of electrocardiogram (ECG) synchronous reconstruction 3D-CT angiography (4D-CTA) using 16 sequence MD-CT to detect weak portions of unruptured cerebral aneurysm. 4D-CT angiography of unruptured cerebral aneurysms was performed on 26 patients, 28 cerebral aneurysms, using 16 sequence MD-CT (GE, HiLight Matrix II). Contrast material of iodine (300 mg/ml) was injected over 30 sec period into the ante-cubital vein with a rate of 0.06 ml/Kg/sec. ECG synchronous reconstruction images (10 images at intervals of 10% between R-R of ECG) were generated (GE, Workstation Advantage 4.1). After careful inspection of the wall motion of an aneurysm from many aspects, cine images were made from several directions. Acquisition of data required 9 seconds, total volume data were generated within 15 minutes, and ECG synchronous reconstruction image processing was performed in about 5 minutes. Animation creation for one direction was completed within one minute. Even in 3-mm aneurysms, changes of its form and size within a heartbeat were fully observed. Timing of maximum and minimum sizes were also recognized. The pulsatile changes and nipple extent, bleb, daughter, and dome of aneurysms were well visualized. The projecting motion of the pulsatory enlargement of nipple was detected in nine cases, and definite increases in bleb sizes were detected in five cases. Since the easily reptured thin walled portion of a cerebral aneurysm can be recognized by this method, 4D-CT angiography is likely to become indispensable in judging how to cope with unruptured cerebral aneurysms, in deciding whether to operate or observe. (author)

  19. Movement of the diaphragm during radiation treatment

    International Nuclear Information System (INIS)

    Nishioka, Masayuki; Fujioka, Tomio; Sakurai, Makoto; Nakajima, Toshifumi; Onoyama, Yasuto.

    1991-01-01

    Movement of the target volume during the exposure to radiation results in decreased accuracy in radiotherapy. We carried out the quantitative evaluation of the movement of the diaphragm during the radiation therapy. Seventy seven patients, who received radiation therapy for lung cancer from December 1988 to February 1990 at the Osaka-prefectural Habikino Hospital, were studied. The movement was recorded with a sonoprinter at the time of treatment planning for radiotherapy, and the length of movement was evaluated at 6 points on the diaphragm. In a study of 402 points in 77 patients, the average movement was 12 mm, and the maximum movement was 40 mm. At the 17% of the points, the movement exceeded 20 mm. The largest movement was observed at the outer point of the right lung. Movement was greater in men than in women. Performance status was not related to the degree of movement. We concluded that in chest and abdominal irradiation, movement caused by respiration is not negligible, and synchronized radiotherapy should be developed in the future. (author)

  20. Process engineering and economic evaluations of diaphragm and membrane chlorine cell technologies. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-12-01

    The chlor-alkali manufacturing technologies of (1), diaphragm cells (2), current technology membrane cells (3), catalytic cathode membrane cells (4), oxygen-cathode membrane cells and to a lesser extent several other related emerging processes are studied. Comparisons have been made on the two bases of (1) conventional industrial economics, and (2) energy consumption. The current diaphragm cell may have a small economic advantage over the other technologies at the plant size of 544 metric T/D (600 T/D). The three membrane cells all consume less energy, with the oxygen-cathode cell being the lowest. The oxygen-cathode cell appears promising as a low energy chlor-alkali cell where there is no chemical market for hydrogen. Federal funding of the oxygen-cathode cell has been beneficial to the development of the technology, to electrochemical cell research, and may help maintain the US's position in the international chlor-alkali technology marketplace. Tax law changes inducing the installation of additional cells in existing plants would produce the quickest reduction in power consumption by the chlor-alkali industry. Alternative technologies such as the solid polymer electrolyte cell, the coupling of diaphragm cells with fuel cells and the dynamic gel diaphragm have a strong potential for reducing chloralkali industry power consumption. Adding up all the recent and expected improvements that have become cost-effective, the electrical energy required to produce a unit of chlorine by 1990 should be only 50% to 60% of that used in 1970. In the United States the majority of the market does not demand salt-free caustic. About 75% of the electrolytic caustic is produced in diaphragm cells and only a small part of that is purified. This study indicates that unless membrane cell costs are greatly reduced or a stronger demand develops for salt-free caustic, the diaphragm cells will remain competitive. (WHK)

  1. The role of Sema3–Npn-1 signaling during diaphragm innervation and muscle development

    Science.gov (United States)

    Huettl, Rosa-Eva; Hanuschick, Philipp; Amend, Anna-Lena; Alberton, Paolo; Aszodi, Attila; Huber, Andrea B.

    2016-01-01

    ABSTRACT Correct innervation of the main respiratory muscle in mammals, namely the thoracic diaphragm, is a crucial pre-requisite for the functionality of this muscle and the viability of the entire organism. Systemic impairment of Sema3A–Npn-1 (Npn-1 is also known as NRP1) signaling causes excessive branching of phrenic nerves in the diaphragm and into the central tendon region, where the majority of misguided axons innervate ectopic musculature. To elucidate whether these ectopic muscles are a result of misguidance of myoblast precursors due to the loss of Sema3A–Npn-1 signaling, we conditionally ablated Npn-1 in somatic motor neurons, which led to a similar phenotype of phrenic nerve defasciculation and, intriguingly, also formation of innervated ectopic muscles. We therefore hypothesize that ectopic myocyte fusion is caused by additional factors released by misprojecting growth cones. Slit2 and its Robo receptors are expressed by phrenic motor axons and migrating myoblasts, respectively, during innervation of the diaphragm. In vitro analyses revealed a chemoattractant effect of Slit2 on primary diaphragm myoblasts. Thus, we postulate that factors released by motor neuron growth cones have an influence on the migration properties of myoblasts during establishment of the diaphragm. PMID:27466379

  2. Reappraisal of CT-grading of subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Nishizawa, Yoshihiko; Kanaya, Haruyuki; Sasaki, Tomio

    1992-01-01

    Delayed ischemic neurological deficit (DIND) after the rupture of cerebral aneurysm remains of the most difficult problems encountered by neurosurgeons. Since the introduction of CT scanning, its clinical application has clarified a close relationship between DIND and the features of subarachnoid hemorrhage (SAH) on CT images. Fisher et al proposed a grading system for SAH based on CT equipment used in the 1980s. Using third-generation CT equipment, we developed a new SAH-grading system to predict the incidence and severity of DIND more precisely. SAH in 109 patients were retrospectively classified according to the CT findings regarding location and density as THIN, THICK, and PACKED (or DENSE). In the THIN group, no DIND appeared. In 44% of patients with THICK group, DIND developed although it was reversible in 75%. On the other hand, DIND was irreversible in 70% of the 56% of PACKEND (or DENSE) group in whom it developed. Moreover, if sequential CT scan demonstrated decrease of the size and density of the SAH, DIND may rarely developed. We therefore conclude that, in order to assess the risk of DIND more precisely, it is very important to obtain repeat CT scans before operation. (author)

  3. Bibliography of paper and thin-layer chromatography 1970-1973 and survey of applications

    International Nuclear Information System (INIS)

    Macek, K.; Hais, I.M.; Kopecky, J.; Schwarz, V.; Gasparic, J.; Churacek, J.

    1976-01-01

    The present volume covers developments in both paper and thin-layer chromatography from 1970 to the middle of 1973 and is a continuation of the previous four volumes, published in 1960, 1962, 1968 and 1972. An author index is given

  4. Automated Diaphragm Loading for the LB/TS (Large Blast/Thermal Simulator).

    Science.gov (United States)

    1986-02-28

    103 87 10 925 Q & T 150 126 132 ill 9 775 Q & T 180 151 163 137 7 575 AISI 4140 ANNEALED 90 76 70 59 15 Q & T 125 105 103 87 10 1025 Q & T 150 126 132...carbon steel diaphragm would be 1.9 inches thick, whereas the heat treated alloy steel diaphragm ( AISI 4130) would be 0.44 inches thick. A normalized...EXPOSURE SPEC TREAT @ RT @ 700 F @ RT @ 700 F PERCENT LIMIT ksi ksi ksi ksi in/in F LOW ALLOY STEELS AISI 4130 ANNEALED 90 76 70 59 15 Q & T 125 105

  5. Hepatopulmonary syndrome induced by common bile duct ligation in a rabbit model: correlation between pulmonary vascular dilatation on thin-section CT and angiography and serum nitrite concentration or endothelial nitric oxide synthase (eNOS)1 expression

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Yoon, Seong Kuk; Lee, Jin Wha; Kim, Ki Nam; Park, Byung Ho; Kwak, Jong Young; Jeong, Jin Sook; Kim, Young Hoon

    2004-01-01

    To investigate the correlation between radiologic vascular dilatation and serum nitrite concentration and eNOS expression in the endothelial cell and pneumocyte in a rabbit model of hepatopulmonary syndrome induced by common bile duct ligation (CBDL). Thin-section CT scans of the lung and pulmonary angiography were obtained 3 weeks after CBDL (n=6), or a sham operation (n=4), and intrapulmonary vasodilatation was assessed. The diameter and tortuosity of peripheral vessels in the right lower lobe by thin-section CT and angiography at the same level of the right lower lobe in all subjects were correlated to serum nitrite concentration and eNOS (endothelial nitric oxide synthase) expression as determined by immunostaining. The diameters of pulmonary vessels on thin-section CT were well correlated with nitrite concentrations in serum (r=0.92, ρ < 0.001). Dilated pulmonary vessels were significantly correlated with an increased eNOS expression (r=0.94, ρ < 0.0001), and the severity of pulmonary vessel tortuosity was found to be well correlated with serum nitrite concentration (r=0.90, ρ < 0.001). The peripheral pulmonary vasculature in hepatopulmonary syndrome induced by CBLD was dilated on thin-section CT and on angiographs. Our findings suggest that peripheral pulmonary vascular dilatations are correlated with serum nitrite concentrations and pulmonary eNOS expression

  6. Comparison of iterative model, hybrid iterative, and filtered back projection reconstruction techniques in low-dose brain CT: impact of thin-slice imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nakaura, Takeshi; Iyama, Yuji; Kidoh, Masafumi; Yokoyama, Koichi [Amakusa Medical Center, Diagnostic Radiology, Amakusa, Kumamoto (Japan); Kumamoto University, Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto (Japan); Oda, Seitaro; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto (Japan); Tokuyasu, Shinichi [Philips Electronics, Kumamoto (Japan); Harada, Kazunori [Amakusa Medical Center, Department of Surgery, Kumamoto (Japan)

    2016-03-15

    The purpose of this study was to evaluate the utility of iterative model reconstruction (IMR) in brain CT especially with thin-slice images. This prospective study received institutional review board approval, and prior informed consent to participate was obtained from all patients. We enrolled 34 patients who underwent brain CT and reconstructed axial images with filtered back projection (FBP), hybrid iterative reconstruction (HIR) and IMR with 1 and 5 mm slice thicknesses. The CT number, image noise, contrast, and contrast noise ratio (CNR) between the thalamus and internal capsule, and the rate of increase of image noise in 1 and 5 mm thickness images between the reconstruction methods, were assessed. Two independent radiologists assessed image contrast, image noise, image sharpness, and overall image quality on a 4-point scale. The CNRs in 1 and 5 mm slice thickness were significantly higher with IMR (1.2 ± 0.6 and 2.2 ± 0.8, respectively) than with FBP (0.4 ± 0.3 and 1.0 ± 0.4, respectively) and HIR (0.5 ± 0.3 and 1.2 ± 0.4, respectively) (p < 0.01). The mean rate of increasing noise from 5 to 1 mm thickness images was significantly lower with IMR (1.7 ± 0.3) than with FBP (2.3 ± 0.3) and HIR (2.3 ± 0.4) (p < 0.01). There were no significant differences in qualitative analysis of unfamiliar image texture between the reconstruction techniques. IMR offers significant noise reduction and higher contrast and CNR in brain CT, especially for thin-slice images, when compared to FBP and HIR. (orig.)

  7. High-resolution CT of the lungs: Anatomic-pathologic correlation

    International Nuclear Information System (INIS)

    Stein, M.G.; Webb, W.R.; Finkbeiner, W.; Gamsu, G.

    1986-01-01

    The interpretation of thin-section (1.5-mm), high-resolution CT scans of the lungs has been limited by lack of direct radiologic and pathologic correlation. The author scanned fresh inflated isolated lungs from ten healthy and five diseased subjects using thin-section, high-resolution techniques. The lungs were then fixed by inflation with endobronchial Formalin. Gough sections (1 mm thick) were obtained at the same levels as the CT scans. In healthy subjects, secondary lobules were identified by the presence of visible interlobular septa and central arterioles. In some patients with disease, septal thickening was visible. In patients with honeycombing cystic areas of destroyed lung were seen, along with areas of fibrosis. Emphysema was well evaluated. Thin-section, high-resolution CT can define lung architecture and may resolve mild changes of the interstitium

  8. CT finding of right retroperitoneal space : analysis of extension of right perirenal hematoma

    International Nuclear Information System (INIS)

    Seo, Kwang Won; Kim, Kyung Rak; Lee, Hyeok; Kim, Young Hwa; Cho, Won Soo; Kim, Il Young

    1997-01-01

    To understand the structure and character of the right retroperitoneal space by analysis of the extension of retroperitoneal hematoma in patients with traumatic right renal injuries. We retrospectively reviewed CT scans of 13 patients with right retroperitoneal hematomas caused by right renal injury. At te renal level, we analyzed the relation of a hematoma contacting psoas muscle with other retroperitoneal compartmental hematomas. At the suprarenal level, a perirenal hematoma and a hematoma contacting the diaphragm were analyzed according to their relation with intrahepatic IVC and pericaval hematoma. Below renal hilar level, all hematomas contacting psoas muscle, observed in eight cases, were connected with retrorenal extension of anterior pararenal hematoma. At the suprarenal level, intrahepatic pericaval hematomas were not, in all 13 cases, connected with a hematoma contacting the diaphragm, but with a perirenal hematoma. At the upper suprarenal level, the only pericaval hematomas containing a medial component of perirenal hematoma extended superiorly to the upper one third of the tenth thoracic vertebral body. The anterior renal fascia envelops perirenal space except in its medial aspect. In the upper suprarenal region, the anterior and posterior planes of the anterior renal fascia unite to fuse with diaphragmatic fascia, but along the medial aspect they fuse with intrahepatic pericaval connective tissue and posteromedial diaphragm, respectively

  9. Feasibility of navigator setting on the left diaphragm for whole-heart coronary MRA. A study in healthy volunteers

    International Nuclear Information System (INIS)

    Watanabe, Kunihiro; Suzuki, Takayoshi; Maruyama, Kazuhiro; Noda, Mayumi; Fujita, Mitsuo; Morita, Satoru; Ohnishi, Takahiro

    2009-01-01

    We prospectively compared the quality of images obtained by navigator setting on the left and right diaphragm on whole-heart coronary magnetic resonance angiography (WHCMRA). In 10 healthy volunteers, we performed free-breathing, 3-dimensional segmented true fast imaging with steady-state precession (trueFISP) WHCMRA by setting the navigator on the left and right diaphragm in random order. For the left diaphragm, we set the navigator outside the scope of the heart to avoid the influence on coronary arteries. We compared image acquisition time and visible length of coronary arteries using paired t-test and subjective image quality on a 4-point scale (1, poor; 4, excellent) using Wilcoxon signed-rank test. Mean overall subjective image quality was significantly better in the left diaphragm than the right (3.3±0.7 versus 2.9±0.9, P=0.02). Mean overall visible length of the coronary arteries was significantly better in the left diaphragm than the right (115.4±31.1 vs. 112.6±29.9 mm, P=0.02). Mean acquisition time between the left and right diaphragm was not significantly different (15.6±5.0 versus 16.0±5.7 min, P=0.79). In this small group of healthy volunteers, navigator setting for WHCMRA was superior on the left diaphragm than the right; however, feasibility of the technique requires additional consideration in a larger group of actual patients. (author)

  10. 900 MW CP1 nuclear steam turbine retrofit thermal effects on low pressure diaphragms

    International Nuclear Information System (INIS)

    Buguin, A.; Gruau, P.; Lamarque, F.; Huggett, J.

    2015-01-01

    The steam turbines of the Koeberg units 1 and 2 operated by ESKOM in South Africa have been retrofitted in order to mitigate the generic problems of stress corrosion cracking of the original shrunk-on disk rotor design. As already done in Belgium and France, the implementation of welded rotors improves the turbine reliability and availability. Moreover, the new technology implemented associated with a new steam path allows a significant performance improvement. With a wealth of experience in CP1 retrofit, ALSTOM has put in place new technical features in the steam path in order to further improve the heat rate. Among them, steam balance holes drilled in the rotor disks have exacerbated the thermal sensitivity of the LP diaphragms. During the commissioning of the Unit 1 LP turbines following the retrofit, the load increase led to unacceptable vibrations. An investigation program was launched to determine the root causes of the problem. This paper presents the findings following the turbine inspection, as well as the recommendations and modifications to allow a smooth return to service of the unit. In addition, the results of the root cause analysis of the vibration incident are explained. Based on finite element calculations and site measurements, ALSTOM has established that the diaphragm thermal behavior, intensified by the steam balance holes, has led to radial rubbing. It was also established that the phenomena had no effect on the diaphragms mechanical integrity. Design changes have been proposed to ensure a safe and reliable long term operation of the units. These modifications have been successfully implemented onto the Koeberg Unit 2 Nuclear Steam Turbine commissioned in November 2012. (authors)

  11. Acquired relaxation of the right half of the diaphragm

    International Nuclear Information System (INIS)

    Tolmachev, V.V.; Romadanov, A.A.

    1997-01-01

    Case is described of the development of complete relaxation of the right half of diaphragm following inflammatory respiratory disease accompanied by infections neuritis involving right phrenic nerve. Results of biomedical radiography and computerized tomography in dynamics are presented

  12. Role of plain radiography and CT angiography in the evaluation of obstructed total anomalous pulmonary venous connection

    International Nuclear Information System (INIS)

    Shen, Quanli; Pa, Mier; Hu, Xihong; Wang, Junbo

    2013-01-01

    Obstructed total anomalous pulmonary venous connection (TAPVC) is frequently misdiagnosed as pulmonary disease and without operative correction early death is common. It is important to make a correct diagnosis before surgery. The purpose of this study was to describe the chest radiographic features of obstructed TAPVC and compare CT angiography with transthoracic echocardiography in the evaluation of obstructed TAPVC. Eighteen children with obstructed TAPVC were assessed. Their clinical and imaging data were retrospectively reviewed. The characteristic radiographic findings were analyzed and compared with surgical results, and the diagnostic accuracy of CT angiography and transthoracic echocardiography was evaluated in terms of pulmonary venous drainage and obstruction detection. The common radiographic features included pulmonary venous congestion or edema or both (16 of 18 cases, 89%), and absence of cardiomegaly (12 of 18 cases, 67%). CT angiography correctly diagnosed TAPVC and clearly revealed the draining sites in all children (five with supracardiac TAPVC, three with cardiac TAPVC, eight with infracardiac TAPVC and two with mixed TAPVC). The diagnostic agreement between CT angiography and surgery was 100%. Transthoracic echocardiography only correctly revealed the draining sites in 11 children (5 with supracardiac TAPVC, 2 with cardiac TAPVC and 4 with infracardiac TAPVC). The diagnostic agreement between transthoracic echocardiography and surgery was 61%. The diagnostic accuracy of CT angiography was higher than that of transthoracic echocardiography (P = 0.0156). Thirty-four sites of obstruction were correctly detected by CT angiography (11 in the mediastinum, 1 at the diaphragmatic level, 9 below the diaphragm and 13 stenotic individual pulmonary veins in the lung). The diagnostic agreement between CT angiography and surgery was 92%. Transthoracic echocardiography only correctly detected 15 sites of obstruction (11 in the mediastinum, 1 at the

  13. Role of plain radiography and CT angiography in the evaluation of obstructed total anomalous pulmonary venous connection

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Quanli; Pa, Mier; Hu, Xihong; Wang, Junbo [Children' s Hospital, Fudan University, Department of Radiology, Shanghai (China)

    2013-07-15

    Obstructed total anomalous pulmonary venous connection (TAPVC) is frequently misdiagnosed as pulmonary disease and without operative correction early death is common. It is important to make a correct diagnosis before surgery. The purpose of this study was to describe the chest radiographic features of obstructed TAPVC and compare CT angiography with transthoracic echocardiography in the evaluation of obstructed TAPVC. Eighteen children with obstructed TAPVC were assessed. Their clinical and imaging data were retrospectively reviewed. The characteristic radiographic findings were analyzed and compared with surgical results, and the diagnostic accuracy of CT angiography and transthoracic echocardiography was evaluated in terms of pulmonary venous drainage and obstruction detection. The common radiographic features included pulmonary venous congestion or edema or both (16 of 18 cases, 89%), and absence of cardiomegaly (12 of 18 cases, 67%). CT angiography correctly diagnosed TAPVC and clearly revealed the draining sites in all children (five with supracardiac TAPVC, three with cardiac TAPVC, eight with infracardiac TAPVC and two with mixed TAPVC). The diagnostic agreement between CT angiography and surgery was 100%. Transthoracic echocardiography only correctly revealed the draining sites in 11 children (5 with supracardiac TAPVC, 2 with cardiac TAPVC and 4 with infracardiac TAPVC). The diagnostic agreement between transthoracic echocardiography and surgery was 61%. The diagnostic accuracy of CT angiography was higher than that of transthoracic echocardiography (P = 0.0156). Thirty-four sites of obstruction were correctly detected by CT angiography (11 in the mediastinum, 1 at the diaphragmatic level, 9 below the diaphragm and 13 stenotic individual pulmonary veins in the lung). The diagnostic agreement between CT angiography and surgery was 92%. Transthoracic echocardiography only correctly detected 15 sites of obstruction (11 in the mediastinum, 1 at the

  14. Liver trauma from penetrating injuries. Miscellanea, personal series, clinical and CT findings

    International Nuclear Information System (INIS)

    Salzano, A.; Nocera, V.; De Rosa, A.; Vigliotti, A.; Rossi, E.; Carbone, M.; Gatta, G.

    2000-01-01

    Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with suspected chest and abdomen involvement CT was performed from the mid-chest for accurate assessment of diaphragm and lung bases and to exclude associated pleuropulmonary damage. Penetrating liver wounds were caused by firearms in 70% of cases, by stabbing in 12% and, in the extant 18%, by other cases such as home accidents, road and work traumas, and liver biopsy. In this series, the liver was most frequently involved, especially by firearms wounds; in the 16 cases the most frequent injuries were hemorrhagic tears. It was found bullets in the liver in 6 cases. In one case of home accident the patient wounded himself while slicing bread with a long knife, which cut into the anterior abdominal wall and tore the anterior liver capsule, as seen at CTA. Penetrating wounds to liver and abdomen are less frequent than those to the chest. In the past decade the use of CT has changed the diagnostic and therapeutic approach to such injuries completely, decreasing the resort to explorative laparotomy and hepatorrhaphy. Indeed, CT provides a clear picture of

  15. CT diagnosis of appendicitis. Usefulness for staging of the disease

    International Nuclear Information System (INIS)

    Abe, Yoshitaka; Shimizu, Tadafumi; Sugimura, Kazurou

    2002-01-01

    The main purpose of this study is to determine signs and indexes useful for differentiating grades of appendicitis (catarrhal, phlegmonous, gangrenous). We assessed CT findings of 98 cases of appendicitis retrospectively. Nonenhanced CT scans were obtained in 83 cases and enhanced scans in 15 cases. No patients were given oral or colon contrast media. Each examination was performed from the level of the diaphragm to the pubic symphysis with 10 mm or 7 mm slice thickness and intervals. All images were examined for CT signs of appendicitis and the diameter and appearance of the appendix. We statistically analyzed the results and white blood cell count. We detected an abnormal appendix in 88 cases. Two CT signs identified and their sensitivity, specificity, and accuracy, respectively, included fat stranding around the appendix (92.2%, 81.8%, 90.9%) and indistinct wall of the appendix (63.9%, 94.2%, 81.8%). The diameter of the appendix differed significantly among the three grades (p=0.0008). The appearance of the appendix could be divided into 5 types, which exhibited correlation with the grades, although white blood cell count did not (p=0.1988). Fat stranding and indistinct wall, and appendix diameter and CT appearances provided useful signs and indexes for staging of appendicitis. (author)

  16. Identifying decreased diaphragmatic mobility and diaphragm thickening in interstitial lung disease: the utility of ultrasound imaging

    Science.gov (United States)

    Santana, Pauliane Vieira; Prina, Elena; Albuquerque, André Luis Pereira; Carvalho, Carlos Roberto Ribeiro; Caruso, Pedro

    2016-01-01

    Objective: To investigate the applicability of ultrasound imaging of the diaphragm in interstitial lung disease (ILD). Methods: Using ultrasound, we compared ILD patients and healthy volunteers (controls) in terms of diaphragmatic mobility during quiet and deep breathing; diaphragm thickness at functional residual capacity (FRC) and at total lung capacity (TLC); and the thickening fraction (TF, proportional diaphragm thickening from FRC to TLC). We also evaluated correlations between diaphragmatic dysfunction and lung function variables. Results: Between the ILD patients (n = 40) and the controls (n = 16), mean diaphragmatic mobility was comparable during quiet breathing, although it was significantly lower in the patients during deep breathing (4.5 ± 1.7 cm vs. 7.6 ± 1.4 cm; p < 0.01). The patients showed greater diaphragm thickness at FRC (p = 0.05), although, due to lower diaphragm thickness at TLC, they also showed a lower TF (p < 0.01). The FVC as a percentage of the predicted value (FVC%) correlated with diaphragmatic mobility (r = 0.73; p < 0.01), and an FVC% cut-off value of < 60% presented high sensitivity (92%) and specificity (81%) for indentifying decreased diaphragmatic mobility. Conclusions: Using ultrasound, we were able to show that diaphragmatic mobility and the TF were lower in ILD patients than in healthy controls, despite the greater diaphragm thickness at FRC in the former. Diaphragmatic mobility correlated with ILD functional severity, and an FVC% cut-off value of < 60% was found to be highly accurate for indentifying diaphragmatic dysfunction on ultrasound. PMID:27167428

  17. Chemically modified cellulose paper as a thin film microextraction phase.

    Science.gov (United States)

    Saraji, Mohammad; Farajmand, Bahman

    2013-11-01

    In this paper, chemically modified cellulose paper was introduced as a novel extracting phase for thin film microextraction (TFME). Different reagents (Octadecyltrichlorosilane, diphenyldichlorosilane, cyclohexyl isocyanate and phenyl isocyanate) were used to modify the cellulose papers. The modified papers were evaluated as a sorbent for the extraction of some synthetic and natural estrogenic hormones (17α-ethynylestradiol, estriol and estradiol) from aqueous samples. Liquid chromatography-fluorescence detection was used for the quantification of the extracted compounds. The cellulose paper modified with phenyl isocyanate showed the best affinity to the target compounds. TEME parameters such as desorption condition, shaking rate, sample ionic strength and extraction time were investigated and optimized. Limit of detections were between 0.05 and 0.23μgL(-1) and relative standard deviations were less than 11.1% under the optimized condition. The calibration curves were obtained in the range of 0.2-100μgL(-1) with a good linearity (r(2)>0.9935). Wastewater, human urine, pool and river water samples were studied as real samples for the evaluation of the method. Relative recoveries were found to be between 75% and 101%. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Acceptability of an existing, female-controlled contraceptive method that could potentially protect against HIV: a comparison of diaphragm users and other method users.

    Science.gov (United States)

    Bird, Sheryl Thorburn; Harvey, S Marie; Maher, Julie E; Beckman, Linda J

    2004-01-01

    The diaphragm, an internal barrier contraceptive device, is a candidate for a female-controlled method for preventing human immunodeficiency virus (HIV) and other sexually transmitted infections (STIs). This study's objective was to examine how women who use the diaphragm differ from women using the pill and/or condoms with respect to factors hypothesized to influence the acceptability of contraceptive methods. Our goal was to increase understanding of who finds the diaphragm acceptable and why. We conducted a cross-sectional telephone survey with selected female members of a managed care organization. For this analysis, we limited the sample to 585 women currently using the diaphragm (n = 196), pill (n = 200), condoms (n = 132), or pill and condoms (n = 57). We conducted bivariate analyses and multinomial logistic regression analyses to assess the associations between selected characteristics and diaphragm use. Diaphragm use was significantly associated with several variables. Of particular interest, placing less importance on hormonal method characteristics was significantly associated with diaphragm use (versus use of the pill, condoms, or both). Placing more importance on barrier method attributes was significantly associated with diaphragm use (versus pill use, alone or with condoms). In addition, lower condom use self-efficacy was significantly associated with diaphragm use (versus condom use, alone or with pill). Lack of motivation to avoid HIV/STIs was significantly associated with using the diaphragm versus condoms (only). These results have important implications for future research, interventions, counseling strategies for providers, and product development. Our findings suggest that if the diaphragm protects against HIV, it could be a desirable option for some women.

  19. A Study for Reappearance According to the Scan Type, the CT Scanning by a Moving Phantom

    International Nuclear Information System (INIS)

    Choi, Jae Hyock; Jeong, Do Hyeong; Choi, Gye Suk; Jang, Yo Jong; Kim, Jae Weon; Lee, Hui Seok

    2007-01-01

    CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Total volume of a marker was 88.2 cm 3 considering movement of superior-inferior. Total volume was 184.3 cm 3 . Total volume according to each CT scan protocol were 135 cm 3 by axial mode, 164.9 cm 3 by helical mode, 181.7 cm 3 by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  20. Multidetector-row CT of right hemidiaphragmatic rupture caused by blunt trauma: a review of 12 cases

    International Nuclear Information System (INIS)

    Rees, O.; Mirvis, S.E.; Shanmuganathan, K.

    2005-01-01

    AIM: To determine the usefulness of multidetector-row CT (MDCT) with multiplanar reformatted (MPR) images in the sagittal and coronal plane in diagnosing acute right hemidiaphragmatic rupture. MATERIALS AND METHODS: Twelve patients were identified who received chest and abdominal MDCT after major blunt trauma diagnosed with right diaphragmatic injury. Sagittal and coronal reformations were performed in all cases. The images were retrospectively reviewed by two experienced radiologists for signs of right diaphragm injury, such as direct diaphragm discontinuity, the 'collar sign', the 'dependent viscera sign', and intra-thoracic location of herniated abdominal contents. RESULTS: Of the 12 cases of right hemidiaphragm rupture, diaphragm discontinuity was seen in seven (58%) cases, the collar sign in five (42%), the dependent viscera sign in four (33%), and transdiaphragmatic herniation of the right colon and fat in another. Two variants of the collar sign were apparent on high-quality sagittal and coronal reformations. The first, termed the 'hump sign', describes a rounded portion of liver herniating through the diaphragm forming a hump-shaped mass, and the second, termed the 'band sign,' is a linear lucency across the liver along the torn edges of the hemidiaphragm. The hump sign occurred in 10 (83%) patients and the band sign in four (33%). CONCLUSION: MDCT is very useful in the diagnosis of right hemidiaphragm injury caused by blunt trauma when sagittal and coronal reformatted images are obtained, and should allow more frequent preoperative diagnosis

  1. CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

    International Nuclear Information System (INIS)

    Schaefer, Philipp J.; Fabel, Michael; Bolte, Hendrik; Schaefer, Fritz K. W.; Jahnke, Thomas; Heller, Martin; Lammer, Johannes; Biederer, Juergen

    2010-01-01

    The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helically bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 ± 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 ± 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 ± 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 ± 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 ± 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.

  2. Scattering study at free air ionization chamber diaphragm

    International Nuclear Information System (INIS)

    Santos, Alexandre Lo Bianco dos

    2011-01-01

    The maim of this work consisted in the assessment of the correction factor for air kerma, due to scattered radiation in the diaphragm of the free-air ionization chamber model 481. LNMRl measurements were made to acquire x-ray spectra corresponding to the Qualities RQR-M, described in IEC 61627 standards (2005). These spectra were used as input data in the MC simulations. The operational range of energy spectra provide up to 35 keV. This energy range is typically used in diagnostic radiology, although there is not primary standard for air kerma. The determination of this factor is a fundamental process in the primary standardization of the air kerma. These factors were obtained by computer simulation using the Penelope code. The results are k RQR-M1 =0,9946, k RQR -M2 =0,9932, k RQR-M3 =0,9978 and k RQR-M4 =0,9885; with uncertainties of 0,007 and coverage factor equal to 2. lt can be concluded that, with respect to the diaphragm, the chamber can be used in the primary standard of air kerma. (author)

  3. Assessment of Diaphragm and External Intercostals Fatigue from Surface EMG using Cervical Magnetic Stimulation

    Directory of Open Access Journals (Sweden)

    Ya-Ju Chang

    2008-03-01

    Full Text Available This study was designed: (1 to test the reliability of surface electromyography (sEMG recording of the diaphragm and external intercostals contractions response to cervical magnetic stimulation (CMS, (2 to examine the amount and the types of inspiratory muscle fatigue that developed after maximum voluntary ventilation (MVV maneuvers.Ten male college students without physical disability (22.1±2.0 years old participated in the study and each completed a control (quiet breathing trial and a fatigue (MVV maneuvers trial sequentially. In the quiet breathing trial, the subjects maintained quiet breathing for five minutes. The subjects performed five maximal static inspiratory efforts and received five CMS before and after the quiet breathing. In the MVV trial, subjects performed five maximal inspiratory efforts and received five CMS before, immediately after, and ten minutes after two sets of MVV maneuvers performed five minutes apart. Maximal inspiratory pressure (PImax, sEMG of diaphragm and external intercostals during maximal static inspiratory efforts and during CMS were recorded. In the quiet breathing trial, high intraclass correlation coefficients (ICC=0.95-0.99 were observed in all the variables. In the MVV trial, the PImax, the EMG amplitude and the median power frequency during maximal static inspiratory efforts significantly decreased in both the diaphragm and the external intercostals immediately after the MVV maneuvers Sensors 2008, 8 2175 (P 0.05. It is concluded that the sEMG recordings of the diaphragm during maximal static inspiratory efforts and in response to CMS allow reproducible sequential assessment of diaphragm contractility. MVV maneuvers resulted in inspiratory muscles fatigue, possibly central fatigue.

  4. Diaphragm remodeling and compensatory respiratory mechanics in a canine model of Duchenne muscular dystrophy.

    Science.gov (United States)

    Mead, A F; Petrov, M; Malik, A S; Mitchell, M A; Childers, M K; Bogan, J R; Seidner, G; Kornegay, J N; Stedman, H H

    2014-04-01

    Ventilatory insufficiency remains the leading cause of death and late stage morbidity in Duchenne muscular dystrophy (DMD). To address critical gaps in our knowledge of the pathobiology of respiratory functional decline, we used an integrative approach to study respiratory mechanics in a translational model of DMD. In studies of individual dogs with the Golden Retriever muscular dystrophy (GRMD) mutation, we found evidence of rapidly progressive loss of ventilatory capacity in association with dramatic morphometric remodeling of the diaphragm. Within the first year of life, the mechanics of breathing at rest, and especially during pharmacological stimulation of respiratory control pathways in the carotid bodies, shift such that the primary role of the diaphragm becomes the passive elastic storage of energy transferred from abdominal wall muscles, thereby permitting the expiratory musculature to share in the generation of inspiratory pressure and flow. In the diaphragm, this physiological shift is associated with the loss of sarcomeres in series (∼ 60%) and an increase in muscle stiffness (∼ 900%) compared with those of the nondystrophic diaphragm, as studied during perfusion ex vivo. In addition to providing much needed endpoint measures for assessing the efficacy of therapeutics, we expect these findings to be a starting point for a more precise understanding of respiratory failure in DMD.

  5. Interlobar fissures involvement by lung cancer. Evaluation with thin-section computed tomography images

    International Nuclear Information System (INIS)

    Kato, Yuji; Yamada, Kouzo; Nomura, Ikuo; Noda, Kazumasa; Ishiwa, Naoki; Maehara, Takamitsu; Kameda, Youichi

    1998-01-01

    Pleural involvement of interlobar fissure by a tumor is one of the most important factors in the clinical diagnosis of lung cancer. A positive finding of incomplete interlobar fissure of the lung influences not only the surgical procedure but also the prognosis. The aim of this retrospective study was to investigate the usefulness of thin-section computed tomography (CT) compared with conventional CT in the detection of pleural invasion of the interlobar fissure by lung cancer or incomplete interlobar fissure, and the results of surgery, according to the involvement of the pleural surface. We reviewed 90 patients whose tumors were adjacent to the interlobar fissure of the lung through conventional CT scans and subsequent thoracotomy. A comparison of diagnoses based on the findings of thin-section CT and pathologic examination showed that thin-section CT was 94% accurate for pleural invasion of the interlobar fissure, and 100% for incomplete interlobar fissure. Conventional CT, however, was only 63% accurate for pleural invasion of the interlobar fissure and 31% for incomplete interlobar fissure. This leads us to conclude that thin-section CT is helpful in the accurate evaluation of pleural invasion of the interlobar fissure and in the findings of incomplete interlobar fissure in lung cancer for patients in whom tumors are adjacent to the interlobar fissure on conventional CT findings. (author)

  6. Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions

    International Nuclear Information System (INIS)

    Yanagawa, Masahiro; Tomiyama, Noriyuki; Sumikawa, Hiromitsu; Inoue, Atsuo; Daimon, Tadahisa; Honda, Osamu; Mihara, Naoki; Johkoh, Takeshi; Nakamura, Hironobu

    2009-01-01

    Purpose: Motion artifacts, which can mimic thickened bronchial wall and the cystic appearance of bronchiectasis, constitute a potential pitfall in the diagnosis of interstitial or bronchial disease. Therefore, purpose of our study was to evaluate whether 64-detector row CT (64-MDCT) enables a reduction in respiratory or cardiac motion artifacts in the lung area on thin-section CT without ECG gating, and to examine the correlation between cardiac motion artifact and heart rate. Materials and methods: Thirty-two patients with suspected diffuse lung disease, who underwent both 8- and 64-MDCT (gantry rotation time, 0.5 and 0.4 s, respectively), were included. The heart rates of an additional 155 patients were measured (range, 48-126 beats per minute; mean, 76 beats per minute) immediately prior to 64-MDCT, and compared to the degree of cardiac motion artifact. Two independent observers evaluated the following artifacts on a monitor without the knowledge of relevant clinical information: (1) artifacts on 8- and 64-MDCT images with 1.25-mm thickness and those on 64-MDCT images with 0.625-mm thickness in 32 patients; and (2) artifacts on 64-MDCT images with 0.625-mm thickness in 155 patients. Results: Interobserver agreement was good in evaluating artifacts on 8-MDCT images with 1.25-mm thickness (weighted Kappa test, κ = 0.61-0.71), and fair or poor in the other evaluations (κ < 0.31). Two observers stated that cardiac motion artifacts were more significant on 8-MDCT than on 64-MDCT in all 32 patients. Statistically significant differences were found at various checkpoints only in comparing artifacts between 8- and 64-MDCT for 1.25-mm thickness (Wilcoxon's signed-rank test, p < 0.0017). Cardiac motion artifacts on 64-MDCT had no significant correlation with heart rate (Spearman's correlation coefficient by rank test). Conclusion: The high temporal resolution of 64-MDCT appears to reduce cardiac motion artifact that can affect thin-section scans of the lung parenchyma

  7. Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions

    Energy Technology Data Exchange (ETDEWEB)

    Yanagawa, Masahiro [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)], E-mail: m-yanagawa@radiol.med.osaka-u.ac.jp; Tomiyama, Noriyuki; Sumikawa, Hiromitsu; Inoue, Atsuo [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Daimon, Tadahisa [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Medicine, Division of Pulmonary Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi 329-0498 (Japan); Honda, Osamu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Mihara, Naoki [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Radiology, Osaka Advanced Medical Imaging Center, 5-20-1 Momoyamadai, Suita-city, Osaka 565-0854 (Japan); Johkoh, Takeshi [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Medical Physics, Osaka University Graduate School of Medicine, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Nakamura, Hironobu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)

    2009-01-15

    Purpose: Motion artifacts, which can mimic thickened bronchial wall and the cystic appearance of bronchiectasis, constitute a potential pitfall in the diagnosis of interstitial or bronchial disease. Therefore, purpose of our study was to evaluate whether 64-detector row CT (64-MDCT) enables a reduction in respiratory or cardiac motion artifacts in the lung area on thin-section CT without ECG gating, and to examine the correlation between cardiac motion artifact and heart rate. Materials and methods: Thirty-two patients with suspected diffuse lung disease, who underwent both 8- and 64-MDCT (gantry rotation time, 0.5 and 0.4 s, respectively), were included. The heart rates of an additional 155 patients were measured (range, 48-126 beats per minute; mean, 76 beats per minute) immediately prior to 64-MDCT, and compared to the degree of cardiac motion artifact. Two independent observers evaluated the following artifacts on a monitor without the knowledge of relevant clinical information: (1) artifacts on 8- and 64-MDCT images with 1.25-mm thickness and those on 64-MDCT images with 0.625-mm thickness in 32 patients; and (2) artifacts on 64-MDCT images with 0.625-mm thickness in 155 patients. Results: Interobserver agreement was good in evaluating artifacts on 8-MDCT images with 1.25-mm thickness (weighted Kappa test, {kappa} = 0.61-0.71), and fair or poor in the other evaluations ({kappa} < 0.31). Two observers stated that cardiac motion artifacts were more significant on 8-MDCT than on 64-MDCT in all 32 patients. Statistically significant differences were found at various checkpoints only in comparing artifacts between 8- and 64-MDCT for 1.25-mm thickness (Wilcoxon's signed-rank test, p < 0.0017). Cardiac motion artifacts on 64-MDCT had no significant correlation with heart rate (Spearman's correlation coefficient by rank test). Conclusion: The high temporal resolution of 64-MDCT appears to reduce cardiac motion artifact that can affect thin-section scans of

  8. Additional effects of FDG-PET to thin-section CT for the differential diagnosis of lung nodules. A Japanese multicenter clinical study

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Murakami, Koji; Inoue, Tomio; Saga, Tsuneo; Shiomi, Susumu

    2011-01-01

    This study was a controlled multicenter clinical study on patients with peripheral lung nodules to verify the improvement in the diagnostic ability of fluorodeoxyglucose-positron emission tomography (FDG-PET) when used in combination with thin-section CT (TS-CT). Patients with peripheral lung nodules (long maximal diameter: 10-30 mm) detected using CT were examined using TS-CT and FDG-PET for the differential diagnosis of benign or malignant lesions. The primary endpoint was the specificity of the results using a combination of TS-CT and FDG-PET, compared with the results for TS-CT alone. Images were interpreted by investigators at each institution. Blind readings were also performed by an independent image interpretation committee. The gold standard was a pathological diagnosis determined using a surgical or biopsy specimen obtained after PET; and the patients in whom a pathological diagnosis could not be obtained were diagnosed based on a follow-up TS-CT performed more than 6 months later. Adverse reactions to FDG were also evaluated. The blind reading results for 82 lesions in 81 subjects eligible for analysis among the 90 subjects included in the study showed a specificity of 91.2% (31/34) (95% confidence interval (CI): 76.3-98.1) for TS-CT + PET, compared with a specificity of 67.6% (23/34) (95% CI: 49.5-82.6) for TS-CT alone. The specificity was significantly improved by the addition of the PET findings (p<0.05). The sensitivity improved from 89.6% (43/48) for TS-CT to 91.7% (44/48) for TS-CT + PET; the addition of PET increased the level of confidence in the diagnosis, but the difference was not significant. The results reported by the institutional investigators were not significantly different. No serious adverse reactions occurred, although two of the 90 subjects exhibited mild adverse reactions. The addition of FDG-PET to TS-CT for the differential diagnosis of benign or malignant peripheral lung nodules resulted in a significant improvement in

  9. Reinforcement of the pelvic diaphragm using a purse-string suture in dogs: description of technique

    Directory of Open Access Journals (Sweden)

    P.C. Moraes

    Full Text Available ABSTRACT Recurrence of perineal hernias is frequent, and is associated to poor identification of anatomical structures during surgery, inadequate suture placement, and failure of physical support of the pelvic diaphragm after surgical reconstruction. The objective of this work is to describe a novel surgical technique for reinforcement of the pelvic diaphragm after performing the internal obturator transposition technique in dogs with perineal hernia.

  10. Overexpression of antioxidant enzymes in diaphragm muscle does not alter contraction-induced fatigue or recovery

    Science.gov (United States)

    McClung, Joseph M.; DeRuisseau, Keith C.; Whidden, Melissa A.; Van Remmen, Holly; Richardson, Arlan; Song, Wook; Vrabas, Ioannis S.; Powers, Scott K.

    2010-01-01

    Low levels of reactive oxygen species (ROS) production are necessary to optimize muscle force production in unfatigued muscle. In contrast, sustained high levels of ROS production have been linked to impaired muscle force production and contraction-induced skeletal muscle fatigue. Using genetically engineered mice, we tested the hypothesis that the independent transgenic overexpression of catalase (CAT), copper/zinc superoxide dismutase (CuZnSOD; SOD1) or manganese superoxide dismutase (MnSOD; SOD2) antioxidant enzymes would negatively affect force production in unfatigued diaphragm muscle but would delay the development of muscle fatigue and enhance force recovery after fatiguing contractions. Diaphragm muscle from wild-type littermates (WT) and from CAT, SOD1 and SOD2 overexpressing mice were subjected to an in vitro contractile protocol to investigate the force–frequency characteristics, the fatigue properties and the time course of recovery from fatigue. The CAT, SOD1 and SOD2 overexpressors produced less specific force (in N cm−2) at stimulation frequencies of 20–300 Hz and produced lower maximal tetanic force than WT littermates. The relative development of muscle fatigue and recovery from fatigue were not influenced by transgenic overexpression of any antioxidant enzyme. Morphologically, the mean cross-sectional area (in μm2) of diaphragm myofibres expressing myosin heavy chain type IIA was decreased in both CAT and SOD2 transgenic animals, and the percentage of non-contractile tissue increased in diaphragms from all transgenic mice. In conclusion, our results do not support the hypothesis that overexpression of independent antioxidant enzymes protects diaphragm muscle from contraction-induced fatigue or improves recovery from fatigue. Moreover, our data are consistent with the concept that a basal level of ROS is important to optimize muscle force production, since transgenic overexpression of major cellular antioxidants is associated with

  11. PO2 cycling reduces diaphragm fatigue by attenuating ROS formation.

    Science.gov (United States)

    Zuo, Li; Diaz, Philip T; Chien, Michael T; Roberts, William J; Kishek, Juliana; Best, Thomas M; Wagner, Peter D

    2014-01-01

    Prolonged muscle exposure to low PO2 conditions may cause oxidative stress resulting in severe muscular injuries. We hypothesize that PO2 cycling preconditioning, which involves brief cycles of diaphragmatic muscle exposure to a low oxygen level (40 Torr) followed by a high oxygen level (550 Torr), can reduce intracellular reactive oxygen species (ROS) as well as attenuate muscle fatigue in mouse diaphragm under low PO2. Accordingly, dihydrofluorescein (a fluorescent probe) was used to monitor muscular ROS production in real time with confocal microscopy during a lower PO2 condition. In the control group with no PO2 cycling, intracellular ROS formation did not appear during the first 15 min of the low PO2 period. However, after 20 min of low PO2, ROS levels increased significantly by ∼30% compared to baseline, and this increase continued until the end of the 30 min low PO2 condition. Conversely, muscles treated with PO2 cycling showed a complete absence of enhanced fluorescence emission throughout the entire low PO2 period. Furthermore, PO2 cycling-treated diaphragm exhibited increased fatigue resistance during prolonged low PO2 period compared to control. Thus, our data suggest that PO2 cycling mitigates diaphragm fatigue during prolonged low PO2. Although the exact mechanism for this protection remains to be elucidated, it is likely that through limiting excessive ROS levels, PO2 cycling initiates ROS-related antioxidant defenses.

  12. PO2 cycling reduces diaphragm fatigue by attenuating ROS formation.

    Directory of Open Access Journals (Sweden)

    Li Zuo

    Full Text Available Prolonged muscle exposure to low PO2 conditions may cause oxidative stress resulting in severe muscular injuries. We hypothesize that PO2 cycling preconditioning, which involves brief cycles of diaphragmatic muscle exposure to a low oxygen level (40 Torr followed by a high oxygen level (550 Torr, can reduce intracellular reactive oxygen species (ROS as well as attenuate muscle fatigue in mouse diaphragm under low PO2. Accordingly, dihydrofluorescein (a fluorescent probe was used to monitor muscular ROS production in real time with confocal microscopy during a lower PO2 condition. In the control group with no PO2 cycling, intracellular ROS formation did not appear during the first 15 min of the low PO2 period. However, after 20 min of low PO2, ROS levels increased significantly by ∼30% compared to baseline, and this increase continued until the end of the 30 min low PO2 condition. Conversely, muscles treated with PO2 cycling showed a complete absence of enhanced fluorescence emission throughout the entire low PO2 period. Furthermore, PO2 cycling-treated diaphragm exhibited increased fatigue resistance during prolonged low PO2 period compared to control. Thus, our data suggest that PO2 cycling mitigates diaphragm fatigue during prolonged low PO2. Although the exact mechanism for this protection remains to be elucidated, it is likely that through limiting excessive ROS levels, PO2 cycling initiates ROS-related antioxidant defenses.

  13. SU-G-BRA-08: Diaphragm Motion Tracking Based On KV CBCT Projections with a Constrained Linear Regression Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Wei, J [City College of New York, New York, NY (United States); Chao, M [The Mount Sinai Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: To develop a novel strategy to extract the respiratory motion of the thoracic diaphragm from kilovoltage cone beam computed tomography (CBCT) projections by a constrained linear regression optimization technique. Methods: A parabolic function was identified as the geometric model and was employed to fit the shape of the diaphragm on the CBCT projections. The search was initialized by five manually placed seeds on a pre-selected projection image. Temporal redundancies, the enabling phenomenology in video compression and encoding techniques, inherent in the dynamic properties of the diaphragm motion together with the geometrical shape of the diaphragm boundary and the associated algebraic constraint that significantly reduced the searching space of viable parabolic parameters was integrated, which can be effectively optimized by a constrained linear regression approach on the subsequent projections. The innovative algebraic constraints stipulating the kinetic range of the motion and the spatial constraint preventing any unphysical deviations was able to obtain the optimal contour of the diaphragm with minimal initialization. The algorithm was assessed by a fluoroscopic movie acquired at anteriorposterior fixed direction and kilovoltage CBCT projection image sets from four lung and two liver patients. The automatic tracing by the proposed algorithm and manual tracking by a human operator were compared in both space and frequency domains. Results: The error between the estimated and manual detections for the fluoroscopic movie was 0.54mm with standard deviation (SD) of 0.45mm, while the average error for the CBCT projections was 0.79mm with SD of 0.64mm for all enrolled patients. The submillimeter accuracy outcome exhibits the promise of the proposed constrained linear regression approach to track the diaphragm motion on rotational projection images. Conclusion: The new algorithm will provide a potential solution to rendering diaphragm motion and ultimately

  14. SU-G-BRA-08: Diaphragm Motion Tracking Based On KV CBCT Projections with a Constrained Linear Regression Optimization

    International Nuclear Information System (INIS)

    Wei, J; Chao, M

    2016-01-01

    Purpose: To develop a novel strategy to extract the respiratory motion of the thoracic diaphragm from kilovoltage cone beam computed tomography (CBCT) projections by a constrained linear regression optimization technique. Methods: A parabolic function was identified as the geometric model and was employed to fit the shape of the diaphragm on the CBCT projections. The search was initialized by five manually placed seeds on a pre-selected projection image. Temporal redundancies, the enabling phenomenology in video compression and encoding techniques, inherent in the dynamic properties of the diaphragm motion together with the geometrical shape of the diaphragm boundary and the associated algebraic constraint that significantly reduced the searching space of viable parabolic parameters was integrated, which can be effectively optimized by a constrained linear regression approach on the subsequent projections. The innovative algebraic constraints stipulating the kinetic range of the motion and the spatial constraint preventing any unphysical deviations was able to obtain the optimal contour of the diaphragm with minimal initialization. The algorithm was assessed by a fluoroscopic movie acquired at anteriorposterior fixed direction and kilovoltage CBCT projection image sets from four lung and two liver patients. The automatic tracing by the proposed algorithm and manual tracking by a human operator were compared in both space and frequency domains. Results: The error between the estimated and manual detections for the fluoroscopic movie was 0.54mm with standard deviation (SD) of 0.45mm, while the average error for the CBCT projections was 0.79mm with SD of 0.64mm for all enrolled patients. The submillimeter accuracy outcome exhibits the promise of the proposed constrained linear regression approach to track the diaphragm motion on rotational projection images. Conclusion: The new algorithm will provide a potential solution to rendering diaphragm motion and ultimately

  15. The Effects of Phrenic Nerve Degeneration by Axotomy and Crush on the Electrical Activities of Diaphragm Muscles of Rats.

    Science.gov (United States)

    Alkiş, Mehmet Eşref; Kavak, Servet; Sayır, Fuat; Him, Aydin

    2016-03-01

    The aim of this study was to investigate the effect of axotomy and crush-related degeneration on the electrical activities of diaphragm muscle strips of experimental rats. In the present study, twenty-one male Wistar-albino rats were used and divided into three groups. The animals in the first group were not crushed or axotomized and served as controls. Phrenic nerves of the rats in the second and third groups were crushed or axotomized in the diaphragm muscle. Resting membrane potential (RMP) was decreased significantly in both crush and axotomy of diaphragm muscle strips of experimental rats (p phrenic nerves may produce electrical activities in the diaphragm muscle of the rat by depolarization time and half-repolarization time prolonged in crush and axotomy rats.

  16. Assessing the need for intermediate diaphragms in prestressed concrete bridges.

    Science.gov (United States)

    2008-03-01

    Reinforced concrete intermediate diaphragms (IDs) are currently being used in prestressed concrete (PC) girder bridges in Louisiana. Some of the advantages of providing IDs are disputed in the bridge community; the use of IDs increases the cost and t...

  17. [Liver trauma due to penetrating lesions: miscellanea, personal case series, clinical and CT findings].

    Science.gov (United States)

    Salzano, A; Nocera, V; De Rosa, A; Rossi, E; Carbone, M; Gatta, G; Vitale, L; Vigliotti, A

    2000-12-01

    Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. We will report the clinical and radiological findings of our personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. We will also try to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years we retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different causes. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with suspected chest and abdomen involvement CT was performed from the mid-chest for accurate assessment of diaphragm and lung bases and to exclude associated pleuropulmonary damage. Penetrating liver wounds were caused by firearms in 70% of cases, by stabbing in 12% and, in the extant 18%, by other causes such as home accidents, road and work traumas, and liver biopsy. In our series, the liver was most frequently involved, especially by firearms wounds; in our 16 cases the most frequent injuries were hemorrhagic tears. We found bullets in the liver in 6 cases. In one case of home accident the patient wounded himself while slicing bread with a long knife, which cut into the anterior abdominal wall and tore the anterior liver capsule, as seen at CTA. Penetrating wounds to liver and abdomen are less frequent than those to the chest. In the past decade the use of CT has changed the diagnostic and therapeutic approach to such injuries completely, decreasing the resort to explorative laparotomy and hepatorrhaphy. Indeed, CT provides a clear picture of the extent and

  18. Degeneration of Phrenic Motor Neurons Induces Long-Term Diaphragm Deficits following Mid-Cervical Spinal Contusion in Mice

    Science.gov (United States)

    Nicaise, Charles; Putatunda, Rajarshi; Hala, Tamara J.; Regan, Kathleen A.; Frank, David M.; Brion, Jean-Pierre; Leroy, Karelle; Pochet, Roland; Wright, Megan C.

    2012-01-01

    Abstract A primary cause of morbidity and mortality following cervical spinal cord injury (SCI) is respiratory compromise, regardless of the level of trauma. In particular, SCI at mid-cervical regions targets degeneration of both descending bulbospinal respiratory axons and cell bodies of phrenic motor neurons, resulting in deficits in the function of the diaphragm, the primary muscle of inspiration. Contusion-type trauma to the cervical spinal cord is one of the most common forms of human SCI; however, few studies have evaluated mid-cervical contusion in animal models or characterized consequent histopathological and functional effects of degeneration of phrenic motor neuron–diaphragm circuitry. We have generated a mouse model of cervical contusion SCI that unilaterally targets both C4 and C5 levels, the location of the phrenic motor neuron pool, and have examined histological and functional outcomes for up to 6 weeks post-injury. We report that phrenic motor neuron loss in cervical spinal cord, phrenic nerve axonal degeneration, and denervation at diaphragm neuromuscular junctions (NMJ) resulted in compromised ipsilateral diaphragm function, as demonstrated by persistent reduction in diaphragm compound muscle action potential amplitudes following phrenic nerve stimulation and abnormalities in spontaneous diaphragm electromyography (EMG) recordings. This injury paradigm is reproducible, does not require ventilatory assistance, and provides proof-of-principle that generation of unilateral cervical contusion is a feasible strategy for modeling diaphragmatic/respiratory deficits in mice. This study and its accompanying analyses pave the way for using transgenic mouse technology to explore the function of specific genes in the pathophysiology of phrenic motor neuron degeneration and respiratory dysfunction following cervical SCI. PMID:23176637

  19. Characteristics of pulmonary cysts in Birt-Hogg-Dube syndrome: Thin-section CT findings of the chest in 12 patients

    Energy Technology Data Exchange (ETDEWEB)

    Tobino, Kazunori, E-mail: tobino@juntendo.ac.jp [Department of Respiratory Medicine, Juntendo University, School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); Gunji, Yoko [Department of Respiratory Medicine, Juntendo University, School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); Kurihara, Masatoshi [Pneumothorax Center, Nissan Tamagawa Hospital, 4-8-1 Seta, Setagaya-Ku, Tokyo 158-0095 (Japan); The Study Group of Pneumothorax and Cystic Lung Diseases, 4-8-1 Seta, Setagaya-Ku, Tokyo 158-0095 (Japan); Kunogi, Makiko; Koike, Kengo [Department of Respiratory Medicine, Juntendo University, School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); Tomiyama, Noriyuki [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan); Johkoh, Takeshi [Department of Radiology, Kinki Central Hospital of Mutual Aid Association of Public School Teachers, Kurumazuka 3-1, Itami, Hyogo 664-0872 (Japan); Kodama, Yuzo [Department of Respiratory Medicine, Juntendo University, School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); Iwakami, Shin-ichiro [Department of Respiratory Medicine, Juntendo University, Shizuoka Hospital, 1129 Nagaoka, Izunokuni, Shizuoka 410-2295 (Japan); Kikkawa, Mika [Biochemical Research Center, Division of Proteomics and Biomolecular Sciences, Juntendo University, Graduate School of Medicine, Bunkyo-Ku, Tokyo (Japan); Takahashi, Kazuhisa [Department of Respiratory Medicine, Juntendo University, School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); Seyama, Kuniaki [Department of Respiratory Medicine, Juntendo University, School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); Study Group of Pneumothorax and Cystic Lung Diseases, 4-8-1 Seta, Setagaya-Ku, Tokyo 158-0095 (Japan)

    2011-03-15

    Purpose: To describe in detail the characteristic chest computed tomography (CT) findings of Birt-Hogg-Dube (BHD) syndrome. Materials and methods: Thin-section chest CT scans of consecutive 12 patients with genetically diagnosed BHD syndrome were retrospectively evaluated by two observers, especially about the characteristics (distribution, number, size, shape and relation to pleura) of pulmonary cysts. Interobserver agreement in the identification of abnormalities on the CT images was achieved using the {kappa} statistic, and the degree of interobserver correlation for the characterization of pulmonary cysts was assessed using the Spearman rank correlation coefficient. Results: Multiple pulmonary cysts were seen in all patients. The number of cysts in each patient was various (range, 29-407), and cysts of various sizes (from a few mm to 2 cm or more) were seen in all patient. 76.6% (mean) of cysts were irregular-shaped, and 40.5% (mean) of cysts were located along the pleura. The mean extent score of cysts was 13% of the whole lung, and the distribution of cysts was predominantly in the lower medial zone. Finally, cysts abutting or including the proximal portions of lower pulmonary arteries or veins were also seen in all patients. Conclusion: Multiple, irregular-shaped cysts of various sizes with lower medial lung zone predominance are characteristic CT findings of BHD syndrome. Cysts abutting or including the proximal portions of lower pulmonary arteries or veins may also exist in this syndrome in a high probability.

  20. Characteristics of pulmonary cysts in Birt-Hogg-Dube syndrome: Thin-section CT findings of the chest in 12 patients

    International Nuclear Information System (INIS)

    Tobino, Kazunori; Gunji, Yoko; Kurihara, Masatoshi; Kunogi, Makiko; Koike, Kengo; Tomiyama, Noriyuki; Johkoh, Takeshi; Kodama, Yuzo; Iwakami, Shin-ichiro; Kikkawa, Mika; Takahashi, Kazuhisa; Seyama, Kuniaki

    2011-01-01

    Purpose: To describe in detail the characteristic chest computed tomography (CT) findings of Birt-Hogg-Dube (BHD) syndrome. Materials and methods: Thin-section chest CT scans of consecutive 12 patients with genetically diagnosed BHD syndrome were retrospectively evaluated by two observers, especially about the characteristics (distribution, number, size, shape and relation to pleura) of pulmonary cysts. Interobserver agreement in the identification of abnormalities on the CT images was achieved using the κ statistic, and the degree of interobserver correlation for the characterization of pulmonary cysts was assessed using the Spearman rank correlation coefficient. Results: Multiple pulmonary cysts were seen in all patients. The number of cysts in each patient was various (range, 29-407), and cysts of various sizes (from a few mm to 2 cm or more) were seen in all patient. 76.6% (mean) of cysts were irregular-shaped, and 40.5% (mean) of cysts were located along the pleura. The mean extent score of cysts was 13% of the whole lung, and the distribution of cysts was predominantly in the lower medial zone. Finally, cysts abutting or including the proximal portions of lower pulmonary arteries or veins were also seen in all patients. Conclusion: Multiple, irregular-shaped cysts of various sizes with lower medial lung zone predominance are characteristic CT findings of BHD syndrome. Cysts abutting or including the proximal portions of lower pulmonary arteries or veins may also exist in this syndrome in a high probability.

  1. CT and PET-CT of a Dog with Multiple Pulmonary Adenocarcinoma

    Science.gov (United States)

    KIM, Jisun; KWON, Seong Young; CENA, Rohani; PARK, Seungjo; OH, Juyeon; OUI, Heejin; CHO, Kyoung-Oh; MIN, Jung-Joon; CHOI, Jihye

    2013-01-01

    ABSTRACT A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog’s euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors’ knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors. PMID:24389742

  2. SU-G-BRA-10: Marker Free Lung Tumor Motion Tracking by An Active Contour Model On Cone Beam CT Projections for Stereotactic Body Radiation Therapy of Lung Cancer

    International Nuclear Information System (INIS)

    Chao, M; Yuan, Y; Lo, Y; Wei, J

    2016-01-01

    Purpose: To develop a novel strategy to extract the lung tumor motion from cone beam CT (CBCT) projections by an active contour model with interpolated respiration learned from diaphragm motion. Methods: Tumor tracking on CBCT projections was accomplished with the templates derived from planning CT (pCT). There are three major steps in the proposed algorithm: 1) The pCT was modified to form two CT sets: a tumor removed pCT and a tumor only pCT, the respective digitally reconstructed radiographs DRRtr and DRRto following the same geometry of the CBCT projections were generated correspondingly. 2) The DRRtr was rigidly registered with the CBCT projections on the frame-by-frame basis. Difference images between CBCT projections and the registered DRRtr were generated where the tumor visibility was appreciably enhanced. 3) An active contour method was applied to track the tumor motion on the tumor enhanced projections with DRRto as templates to initialize the tumor tracking while the respiratory motion was compensated for by interpolating the diaphragm motion estimated by our novel constrained linear regression approach. CBCT and pCT from five patients undergoing stereotactic body radiotherapy were included in addition to scans from a Quasar phantom programmed with known motion. Manual tumor tracking was performed on CBCT projections and was compared to the automatic tracking to evaluate the algorithm accuracy. Results: The phantom study showed that the error between the automatic tracking and the ground truth was within 0.2mm. For the patients the discrepancy between the calculation and the manual tracking was between 1.4 and 2.2 mm depending on the location and shape of the lung tumor. Similar patterns were observed in the frequency domain. Conclusion: The new algorithm demonstrated the feasibility to track the lung tumor from noisy CBCT projections, providing a potential solution to better motion management for lung radiation therapy.

  3. SU-G-BRA-10: Marker Free Lung Tumor Motion Tracking by An Active Contour Model On Cone Beam CT Projections for Stereotactic Body Radiation Therapy of Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chao, M; Yuan, Y; Lo, Y [The Mount Sinai Medical Center, New York, NY (United States); Wei, J [City College of New York, New York, NY (United States)

    2016-06-15

    Purpose: To develop a novel strategy to extract the lung tumor motion from cone beam CT (CBCT) projections by an active contour model with interpolated respiration learned from diaphragm motion. Methods: Tumor tracking on CBCT projections was accomplished with the templates derived from planning CT (pCT). There are three major steps in the proposed algorithm: 1) The pCT was modified to form two CT sets: a tumor removed pCT and a tumor only pCT, the respective digitally reconstructed radiographs DRRtr and DRRto following the same geometry of the CBCT projections were generated correspondingly. 2) The DRRtr was rigidly registered with the CBCT projections on the frame-by-frame basis. Difference images between CBCT projections and the registered DRRtr were generated where the tumor visibility was appreciably enhanced. 3) An active contour method was applied to track the tumor motion on the tumor enhanced projections with DRRto as templates to initialize the tumor tracking while the respiratory motion was compensated for by interpolating the diaphragm motion estimated by our novel constrained linear regression approach. CBCT and pCT from five patients undergoing stereotactic body radiotherapy were included in addition to scans from a Quasar phantom programmed with known motion. Manual tumor tracking was performed on CBCT projections and was compared to the automatic tracking to evaluate the algorithm accuracy. Results: The phantom study showed that the error between the automatic tracking and the ground truth was within 0.2mm. For the patients the discrepancy between the calculation and the manual tracking was between 1.4 and 2.2 mm depending on the location and shape of the lung tumor. Similar patterns were observed in the frequency domain. Conclusion: The new algorithm demonstrated the feasibility to track the lung tumor from noisy CBCT projections, providing a potential solution to better motion management for lung radiation therapy.

  4. Morphological and ultrastructural evaluation of the golden retriever muscular dystrophy trachea, lungs, and diaphragm muscle.

    Science.gov (United States)

    Lessa, Thais Borges; de Abreu, Dilayla Kelly; Rodrigues, Márcio Nogueira; Brólio, Marina Pandolphi; Miglino, Maria Angélica; Ambrósio, Carlos Eduardo

    2014-11-01

    Duchenne muscular dystrophy (DMD) is a genetic disease, characterized by atrophy and muscle weakness. The respiratory failure is a common cause of early death in patients with DMD. Golden retriever muscular dystrophy (GRMD) is a canine model which has been extensively used for many advances in therapeutics applications. As the patients with DMD, the GRMD frequently died from cardiac and respiratory failure. Observing the respiratory failure in DMD is one of the major causes of mortality we aimed to describe the morphological and ultrastructural data of trachea, lungs (conductive and respiratory portion of the system), and diaphragm muscle using histological and ultrastructural analysis. The diaphragm muscle showed discontinuous fibers architecture, with different diameter; a robust perimysium inflammatory infiltrate and some muscle cells displayed central nuclei. GRMD trachea and lungs presented collagen fibers and in addition, the GRMD lungs showed higher of levels collagen fibers that could limit the alveolar ducts and alveoli distension. Therefore, the most features observed were the collagen areas and fibrosis. We suggested in this study that the collagen remodeling in the trachea, lungs, and diaphragm muscle may increase fibrosis and affect the trachea, lungs, and diaphragm muscle function that can be a major cause of respiratory failure that occur in patients with DMD. © 2014 Wiley Periodicals, Inc.

  5. Changes in the Diaphragm Lipid Content after Administration of Streptozotocin and High-Fat Diet Regime

    Directory of Open Access Journals (Sweden)

    Bartlomiej Lukaszuk

    2017-01-01

    Full Text Available The diaphragm is a dome-shaped skeletal muscle indispensable for breathing. Its activity contributes up to 70% of the total ventilatory function at rest. In comparison to other skeletal muscles, it is distinguished by an oxidative phenotype and uninterrupted cyclic contraction pattern. Surprisingly, the research regarding diaphragm diabetic phenotype particularly in the light of lipid-induced insulin resistance is virtually nonexistent. Male Wistar rats were randomly allocated into 3 groups: control, streptozotocin-induced (STZ type-1 diabetes, and rodents fed with high-fat diet (HFD. Additionally, half of the animals from each group were administered with myriocin, a robust, selective inhibitor of ceramide synthesis and, therefore, a potent agent ameliorating insulin resistance. Diaphragm lipid contents were evaluated using chromatography. Fatty acid transporter expression was determined by Western blot. The STZ and HFD rats had increased concentration of lipids, namely, ceramides (CER and diacylglycerols (DAG. Interestingly, this coincided with an increased concentration of long-chain (C ≥ 16 saturated fatty acid species present in both the aforementioned lipid fractions. The CER/DAG accumulation was accompanied by an elevated fatty acid transporter expression (FATP-1 in HFD and FATP-4 in STZ. Surprisingly, we observed a significantly decreased triacylglycerol content in the diaphragms of STZ-treated rats.

  6. Visualization of the diaphragm muscle with ultrasound improves diagnostic accuracy of phrenic nerve conduction studies.

    Science.gov (United States)

    Johnson, Nicholas E; Utz, Michael; Patrick, Erica; Rheinwald, Nicole; Downs, Marlene; Dilek, Nuran; Dogra, Vikram; Logigian, Eric L

    2014-05-01

    Evaluation of phrenic neuropathy (PN) with phrenic nerve conduction studies (PNCS) is associated with false negatives. Visualization of diaphragmatic muscle twitch with diaphragm ultrasound (DUS) when performing PNCS may help to solve this problem. We performed bilateral, simultaneous DUS-PNCS in 10 healthy adults and 12 patients with PN. The amplitude of the diaphragm compound muscle action potential (CMAP) (on PNCS) and twitch (on DUS) was calculated. Control subjects had phrenic CMAP (on PCNS). In the 12 patients with PN, 12 phrenic neuropathies were detected. Three of these patients had either significant side-to-side asymmetry or absolute reduction in diaphragm movement that was not detected with PNCS. There were no cases in which the PNCS showed an abnormality but the DUS did not. The addition of DUS to PNCS enhances diagnostic accuracy in PN. Copyright © 2013 Wiley Periodicals, Inc.

  7. Treatment of craniopharyngioma estimated by follow-up CT

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, T.; Ito, H.; Aizumi, S.; Yamamoto, S.; (Kanazawa Univ. (Japan). School of Medicine)

    1981-12-01

    Follow-up CT scans were taken from 12 cases of craniopharyngiomas after various treatment. Preoperative CT findings of craniopharyngiomas could be classified into three types. Type 1 was a non-enhanced or a thinly ring-like enhanced large cystic mass. Type 2 was a thickly enhanced large cystic mass with small solid mass. Type 3 was a large solid mass. Postoperative follow-up CT findings were as follows: Type 1 had a favorable postoperative course because the tumor tissues of the thin cystic wall seemed to collapse only with the procedure of cystic fluid aspiration. Recurrence frequently took place in patients of Type 2 and 3 if the tumor couldn't be radically removed or radiotherapy was not given after partial resection. Radiotherapy was most effective in these cases.

  8. Treatment of craniopharyngioma estimated by follow-up CT

    International Nuclear Information System (INIS)

    Kubota, Toshihiko; Ito, Haruhide; Aizumi, Shinichi; Yamamoto, Shinjiro

    1981-01-01

    Follow-up CT scans were taken from 12 cases of craniopharyngiomas after various treatment. Preoperative CT findings of craniopharyngiomas could be classified into three types. Type 1 was a non-enhanced or a thinly ring-like enhanced large cystic mass. Type 2 was a thickly enhanced large cystic mass with small solid mass. Type 3 was a large solid mass. Postoperative follow-up CT findings were as follows: Type 1 had a favorable postoperative course because the tumor tissues of the thin cystic wall seemed to collapse only with the procedure of cystic fluid aspiration. Recurrence frequently took place in patients of Type 2 and 3 if the tumor couldn't be radically removed or radiotherapy was not given after partial resection. Radiotherapy was most effective in these cases. (author)

  9. Traumatic rupture of the diaphragm | Jamabo | Sahel Medical Journal

    African Journals Online (AJOL)

    Those treated for traumatic rupture of the diaphragm were selected and analyzed for age, gender, cause of injury, associated injuries sustained and mode of treatment. They were all treated at the University of Port Harcourt Teaching Hospital and a private clinic in Port Harcourt. Results: 12 patients had traumatic rupture of ...

  10. Benign pulmonary nodule. Morphological features and contrast enhancement evaluated with contiguous thin-section CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsuo, Hisayasu; Murata, Kiyoshi; Takahashi, Masashi; Morita, Rikushi [Shiga Univ. of Medical Science, Otsu (Japan)

    1998-10-01

    The morphological changes in 54 benign lung nodules, including 8 histologically proven nodules of tuberculoma, 10 of focal organizing pneumonia (FOP), 1 of lung abscess and 35 other benign nodules, were evaluated with contiguous thin-section (3 mm) CT. In addition, incremental dynamic studies were carried out in 25 of these nodules. The three-dimensional shapes of the nodules were found to be quite varied and were classified into four types: round mass (n=18), polygonal mass with concave or straight margins (n=20), oval or band-like mass extending along the bronchovascular bundle (n=7), and oval mass attached to the pleura with broad contact (n=9). Forty-two (78%) of the 54 nodules were located along the bronchovascular bundle. The maximum increments in CT values over 20 HU were observed after contrast enhancement in 18 (72%) of the 25 benign nodules, among which all tuberculomas showed little or no contrast enhancement. The number of small vessels quantified microscopically in the center of the nodules were minimal in tuberculomas with little enhancement and plentiful in lesions of FOP and abscess which showed marked enhancement. Our results suggest that the differentiation between benign and malignant pulmonary nodules is not possible simply on the basis of the degree of contrast enhancement. Therefore, morphological features and the anatomical relation to the bronchovascular bundles should also be taken into consideration in the diagnosis of pulmonary nodules. (author)

  11. Benign pulmonary nodule. Morphological features and contrast enhancement evaluated with contiguous thin-section CT

    International Nuclear Information System (INIS)

    Matsuo, Hisayasu; Murata, Kiyoshi; Takahashi, Masashi; Morita, Rikushi

    1998-01-01

    The morphological changes in 54 benign lung nodules, including 8 histologically proven nodules of tuberculoma, 10 of focal organizing pneumonia (FOP), 1 of lung abscess and 35 other benign nodules, were evaluated with contiguous thin-section (3 mm) CT. In addition, incremental dynamic studies were carried out in 25 of these nodules. The three-dimensional shapes of the nodules were found to be quite varied and were classified into four types: round mass (n=18), polygonal mass with concave or straight margins (n=20), oval or band-like mass extending along the bronchovascular bundle (n=7), and oval mass attached to the pleura with broad contact (n=9). Forty-two (78%) of the 54 nodules were located along the bronchovascular bundle. The maximum increments in CT values over 20 HU were observed after contrast enhancement in 18 (72%) of the 25 benign nodules, among which all tuberculomas showed little or no contrast enhancement. The number of small vessels quantified microscopically in the center of the nodules were minimal in tuberculomas with little enhancement and plentiful in lesions of FOP and abscess which showed marked enhancement. Our results suggest that the differentiation between benign and malignant pulmonary nodules is not possible simply on the basis of the degree of contrast enhancement. Therefore, morphological features and the anatomical relation to the bronchovascular bundles should also be taken into consideration in the diagnosis of pulmonary nodules. (author)

  12. Development of diaphragm automatic homing equipment

    International Nuclear Information System (INIS)

    Kobayashi, Hidetoshi; Yamada, Koji; Moriya, Shinichi; Koike, Jiro; Okabe, Masao; Oyama, Akihiro.

    1996-01-01

    In steam-turbine overhaul inspection, one of the most important processes is to remove rust and deposited contaminants on the surface of turbine parts, while the turbine is in operation, to recover thermal efficiency and prepare good surface conditions for color penetrant inspection. These processes generally are done by dry honing, but this generates dust. To protect laborers against these conditions, Hitachi, Ltd. has developed automatic honing equipment for the diaphragms of the nuclear steam turbine. This equipment was first used in the first annual inspection and overhaul of Hamaoka Nuclear Power Plant No.4 of Chubu Electric Power Inc. (author)

  13. Aviation Fuel Gauging Sensor Utilizing Multiple Diaphragm Sensors Incorporating Polymer Optical Fiber Bragg Gratings

    DEFF Research Database (Denmark)

    Marques, C. A. F.; Pospori, A.; Saez-Rodriguez, D.

    2016-01-01

    A high-performance fuel gauging sensor is described that uses five diaphragm-based pressure sensors, which are monitored using a linear array of polymer optical fiber Bragg gratings. The sensors were initially characterized using water, revealing a sensitivity of 98 pm/cm for four of the sensors...... of sensors manufactured with a polyurethane-based diaphragm showed no measurable deterioration over a three month period immersed in fuel. These sensors exhibited a sensitivity of 39 pm/cm, which is less than the silicone rubber devices due to the stiffer nature of the polyurethane material used....

  14. The value of the abnormalities of bronchovascular bundles in the diagnosis of diffused lung diseases

    International Nuclear Information System (INIS)

    Li Tieyi; Ji Jingling

    1997-01-01

    To evaluate the abnormalities of bronchovascular bundles in the differential diagnosis of the diffuse lung disease, seventy-two patients with diffuse lung diseases were evaluated, 15 of 72 patients were pathologically proven and the others clinically proven. Of these 72 patients, there were 33 patients with diffuse pulmonary interstitial disease, 5 patients with pulmonary parenchymal disease, 14 patients with bronchial disease, and 20 patients with disseminated disease. All patients had conventional CT scan of the chest, some also had HRCT scan. All CT images were jointly reviewed by two radiologists. The features of the abnormalities of bronchovascular bundles included: (1) Thinning of bronchovascular bundles, predominantly seen in diffuse interstitial disease of lung and chronic bronchitis; (2) thickening of bronchovascular bundles, predominantly seen in interstitial diseases and disseminated lung diseases such as sarcoidosis and lymphangitis carcinomatosis with beaded appearance of bronchovascular bundles; (3) Increased visibility of bronchovascular bundles, predominantly seen in bronchiolitis and disseminated lung diseases. CT features of the abnormalities of bronchovascular bundles are present in 80% of diffuse lung diseases. The features are not specific, but the beaded bronchovascular bundles are always seen in sarcoidosis and lymphangitis carcinomatosis. In making a distinction between idiopathic pulmonary fibrosis and chronic bronchitis complicated with interstitial fibrosis, the position of diaphragm is of value in differential diagnosis, normal or elevated diaphragm is usually seen in the former, while low and flattened diaphragm in the latter. Change of the appearance of bronchovascular bundles from normality to abnormality reflects the process of development of the lung disease

  15. Potential for Revitalisation of the Diaphragm for Family Planning in ...

    African Journals Online (AJOL)

    AJRH Managing Editor

    diaphragm, into the existing family planning method mix in Uganda. A total of 26 ... expand women's options for contraceptive protection. ... several countries, and the product was approved in ..... younger clients and may not adequately market ... different stages of their life cycle. .... maternal mortality ratio in Uganda: priority.

  16. SU-E-T-217: Intrinsic Respiratory Gating in Small Animal CT

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y; Smith, M; Mistry, N [University of Maryland School of Medicine, Baltimore, MD (United States)

    2014-06-01

    Purpose: Preclinical animal models of lung cancer can provide a controlled test-bed for testing dose escalation or function-based-treatment-planning studies. However, to extract lung function, i.e. ventilation, one needs to be able to image the lung at different phases of ventilation (in-hale / ex-hale). Most respiratory-gated imaging using micro-CT involves using an external ventilator and surgical intervention limiting the utility in longitudinal studies. A new intrinsic respiratory retrospective gating method was developed and tested in mice. Methods: A fixed region of interest (ROI) that covers the diaphragm was selected on all projection images to estimate the mean intensity (M). The mean intensity depends on the projection angle and diaphragm position. A 3-point moving average (A) of consecutive M values: Mpre, Mcurrent and Mpost, was calculated to be subtracted from Mcurrent. A fixed threshold was used to enable amplitude based sorting into 4 different phases of respiration. Images at full-inhale and end-exhale phases of respiration were reconstructed using the open source OSCaR. Lung volumes estimated at the 2 phases of respiration were validated against literature values. Results: Intrinsic retrospective gating was accomplished without the use of any external breathing waveform. While projection images were acquired at 360 different angles. Only 138 and 104 projections were used to reconstruct images at full-inhale and end-exhale. This often results in non-uniform under-sampled angular projections leading to some minor streaking artifacts. The calculated expiratory, inspiratory and tidal lung volumes correlated well with the values known from the literature. Conclusion: Our initial result demonstrates an intrinsic gating method that is suitable for flat panel cone beam small animal CT systems. Reduction in streaking artifacts can be accomplished by oversampling the data or using iterative reconstruction methods. This initial experience will enable

  17. Application of artificial neural networks in the CT study of solitary pulmonary nodule

    International Nuclear Information System (INIS)

    Wang Xiaohua; Ma Daqing; Chen Hui; Gao Peiyi; Zhou Xinhua

    2006-01-01

    Objective: To establish a new-type discriminative method in differentiating benign from malignant solitary pulmonary nodule (SPN) on high-resolution CT/thin-section CT by using artificial neural networks theory in the CT diagnostic study of SPN. Methods: Two hundred SPNs pathologically proved by operation or biopsy (primary pulmonary carcinoma 135 eases, benign nodules 65 cases) were collected, 3 clinical characteristics (age, sex, with or without bloody sputum) and 9 high-resolution CT/thin-section CT characteristics (location, long and short diameter, contour, spiculation, halo sign, air-space, relation with the adjacent blood vessels and pleura) were analyzed. 140 cases were randomly selected to form the training samples, on which artificial neural networks model (BP networks) was built and compared with Logistic model from Statistical Package for the Social Science (SPSS) software. Results: The total consistent rate of BP neural networks (98.0%, 196/200) was higher than that of Logistic model (86.0%, 172/200) (P<0.001). Areas under ROC curve were 0.996±0.004 and 0.936±0.017, respectively, and the difference between the two was significant (P<0.001). Conclusion: Using high-resolution CT and thin-section CT in combination with artificial neural networks theory is feasible, and it is expected to become a useful and reliable clinical tool in differentiating benign from malignant SPN. (authors)

  18. Mechanical characterization of the mouse diaphragm with optical coherence elastography reveals fibrosis-related change of direction-dependent muscle tissue stiffness

    Science.gov (United States)

    Wang, Shang; Loehr, James A.; Larina, Irina V.; Rodney, George G.; Larin, Kirill V.

    2016-03-01

    The diaphragm, composed of skeletal muscle, plays an important role in respiration through its dynamic contraction. Genetic and molecular studies of the biomechanics of mouse diaphragm can provide great insights into an improved understanding and potential treatment of the disorders that lead to diaphragm dysfunction (i.e. muscular dystrophy). However, due to the small tissue size, mechanical assessment of mouse diaphragm tissue under its proper physiological conditions has been challenging. Here, we present the application of noncontact optical coherence elastography (OCE) for quantitative elastic characterization of ex vivo mouse diaphragm. Phase-sensitive optical coherence tomography was combined with a focused air-puff system to capture and measure the elastic wave propagation from tissue surface. Experiments were performed on wildtype and dystrophic mouse diaphragm tissues containing different levels of fibrosis. The OCE measurements of elastic wave propagation were conducted along both the longitudinal and transverse axis of the muscle fibers. Cross-correlation of the temporal displacement profiles from different spatial locations was utilized to obtain the propagation time delay, which was used to calculate the wave group velocity and to further quantify the tissue Young's modulus. Prior to and after OCE assessment, peak tetanic force was measured to monitor viability of the tissue during the elasticity measurements. Our experimental results indicate a positive correlation between fibrosis level and tissue stiffness, suggesting this elastic-wave-based OCE method could be a useful tool to monitor mechanical properties of skeletal muscle under physiological and pathological conditions.

  19. Molecular Weiss domain polarization in piezoceramics to diaphragm, cantilever and channel construction in low-temperature-cofired ceramics for micro-fluidic applications

    International Nuclear Information System (INIS)

    Khanna, P.K.; Ahmad, S.; Grimme, R.

    2005-01-01

    This paper presents the efforts made to study the process of comminution to Weiss domain polarization and phase transition in piezoceramics together with the versatility of low-temperature-cofired ceramics-based devices and components for their ready adoption for typical applications in the area of micro-fluidics. A conceptual micro-fluidic module has been presented and few unit entities necessary for its realization have been described. The purpose of these entities is to position the sensors and actuators by using piezoelectric materials. Investigations are performed to make useful constructions like diaphragms and cantilevers for laying the sensing elements, cavities for burying the electronic chip devices, and channels for fluid transportation. In order to realize these constructions, the basic step involves machining of circular, straight line, rectangular and square-shaped structure in the green ceramic tapes followed by lamination and firing with post-machining in some cases. The diaphragm and cavity includes one or more un-machined layer stacked together with several machined layers with rectangular or square slits. The cantilever is an extension of the diaphragm creation process with inclusion of a post-machining step. The channel essentially consists of a machined green ceramic layer sandwiched between an un-machined and a partially machined layer. The fabrication for all the above constructions has been exemplified and the details have been discussed

  20. Potential for Revitalisation of the Diaphragm for Family Planning in ...

    African Journals Online (AJOL)

    This health systems assessment evaluated the feasibility of introducing a new contraceptive device, the SILCS single-size diaphragm, into the existing family planning method mix in Uganda. A total of 26 focus group discussions with 201 female and 77 male potential users and 98 key informant interviews with policymakers ...

  1. Evaluation of benign pulmonary lesions less than 20 mm in diameter by thin-section computed tomography

    International Nuclear Information System (INIS)

    Shiotani, Seiji; Yamada, Kouzo; Oshita, Fumihiro

    1997-01-01

    To establish diagnostic criteria for small solitary pulmonary nodules, the findings of thin-section computed tomography (CT) were compared with pathological findings. We evaluated thin-section CT images and compared them with pathological findings in 23 specimens of resected benign lesions less than 20 mm in diameter located in the peripheral region. The thin-section CT images were reconstructed using 2 mm thick sections taken by TCT-900S, HELIX (Toshiba, Tokyo) and were examined with two different windows and level settings. In every case, the surgical specimens were sliced transversely to correlate with the CT findings. The thin-section CT images were classified into two types; solid and air-containing types. The former consisted of benign pulmonary tumors, granulomas and some focal fibrosis, while the latter all consisted of focal fibrosis. Both types were difficult to distinguish from peripheral lung cancer based only on margin analysis of the lesion, but analysis of how pulmonary vessels relate to the lesion can allow benign pulmonary lesions to be distinguished from peripheral lung cancer. (author)

  2. Advanced performance of small diaphragm vacuum pumps through the use of mechatronics

    Science.gov (United States)

    Lachenmann, R.; Dirscherl, J.

    Oil-free diaphragm vacuum pumps have proven to be the best way in vacuum generation for the chemical laboratory and they also find increasing use as backing pumps for modern wide-range turbo molecular pumps. The majority of vacuum pumps in practical use pump only a rather small percentage of their lifetime at full gas load. A pump backing a turbo molecular pump does not have to pump a significant gas load when the high-vacuum pump is running at ultimate vacuum pressure. Also, for a vacuum distillation the vacuum pump has to operate at full speed only at the beginning to lower the pressure inside the system to a vacuum level where evaporation starts. In a rather leak-tight system the distillation process continues by evaporating from the hot liquid and condensing at the cold condenser without the need of a mechanical vacuum pump. Rotational speed controlled diaphragm pumps are now available through progress in mechatronics and offer high pumping speed capability for fast pump-down cycles and precise pressure control for distillations. At low gas load the rotational speed can be reduced, improving maintenance intervals, power consumption, noise, vibration and - surprisingly - also ultimate pressure. The different behaviour in pumping speed and ultimate pressure of rotational speed controlled diaphragm pumps in comparison to constant-speed pumps is related to the mechanical properties of the valves and gas dynamics .

  3. High temperature energy harvesters utilizing ALN/3C-SiC composite diaphragms

    Science.gov (United States)

    Lai, Yun-Ju; Li, Wei-Chang; Felmetsger, Valery V.; Senesky, Debbie G.; Pisano, Albert P.

    2014-06-01

    Microelectromechanical systems (MEMS) energy harvesting devices aiming at powering wireless sensor systems for structural health monitoring in harsh environments are presented. For harsh environment wireless sensor systems, sensor modules are required to operate at elevated temperatures (> 250°C) with capabilities to resist harsh chemical conditions, thereby the use of battery-based power sources becomes challenging and not economically efficient if considering the required maintenance efforts. To address this issue, energy harvesting technology is proposed to replace batteries and provide a sustainable power source for the sensor systems towards autonomous harsh environment wireless sensor networks. In particular, this work demonstrates a micromachined aluminum nitride/cubic silicon carbide (AlN/3C-SiC) composite diaphragm energy harvester, which enables high temperature energy harvesting from ambient pulsed pressure sources. The fabricated device yields an output power density of 87 μW/cm2 under 1.48-psi pressure pulses at 1 kHz while connected to a 14.6-kΩ load resistor. The effects of pulse profile on output voltage have been studied, showing that the output voltage can be maximized by optimizing the diaphragm resonance frequency based on specific pulse characteristics. In addition, temperature dependence of the diaphragm resonance frequency over the range of 20°C to 600°C has been investigated and the device operation at temperatures as high as 600°C has been verified.

  4. Tumor motion prediction with the diaphragm as a surrogate: a feasibility study

    International Nuclear Information System (INIS)

    Cervino, Laura I; Jiang Yan; Sandhu, Ajay; Jiang, Steve B

    2010-01-01

    We have previously assessed the use of the diaphragm as a surrogate for predicting real-time tumor position with linear models built with training data extracted from the same treatment fraction (Cervino et al 2009 Phys. Med. Biol. 54 3529-41). However, practical use in the clinical setting requires the capability of predicting tumor position throughout the treatment course using a model built at the beginning of the course. We evaluate the inter-fraction applicability of linear models to predict superior-inferior tumor position based on diaphragm position using 21 fluoroscopic sequences from five lung cancer patients. Tumor position is predicted with models built during the first fluoroscopic sequence of each patient. Other fluoroscopic sets are registered to the first set with five different methods. The mean localization prediction error and maximum error at a 95% confidence level averaged over all patients are found to be 1.2 mm and 2.9 mm, respectively, for bony registration and 1.2 mm and 2.8 mm, respectively, for registration based on the mean position of the tumor in the first two breathing cycles. Other registration methods produce larger prediction errors. In the clinical setting, this prediction error could be added as a margin to the target volume. We therefore conclude that it is feasible to predict lung tumor motion with diaphragm with sufficient accuracy in the clinical setting. (note)

  5. Dystrophic phenotype improvement in the diaphragm muscle of mdx mice by diacerhein.

    Directory of Open Access Journals (Sweden)

    Rafael Dias Mâncio

    Full Text Available Chronic inflammation and oxidative stress are striking features of Duchenne muscular dystrophy disease. Diacerhein is an anthraquinone, which exhibits anti-inflammatory and antioxidant properties. Based on their actions, the present study evaluated the effects of diacerhein against myonecrosis, oxidative stress and inflammatory response in the diaphragm muscle of mdx mice and compared these results to current treatment widely used in DMD patients, with a main focus on the impact of prednisone. The results demonstrated that diacerhein treatment prevented muscle damage indicated by a decrease in the IgG uptake by muscle fibers, lower CK levels in serum, reduction of fibers with central nuclei with a concomitant increase in fibers with peripheral nuclei. It also had an effect on the inflammatory process, decreasing the inflammatory area, macrophage staining and TNF-α and IL-1β content. Regarding oxidative stress, diacerhein treatment was effective in reducing the ROS and lipid peroxidation in the diaphragm muscle from mdx mice. Compared to prednisone treatment, our findings demonstrated that diacerhein treatment improved the dystrophic phenotype in the diaphragm muscle of mdx mice similar to that of glucocorticoid therapy. In this respect, this work suggests that diacerhein has a potential use as an alternative drug in dystrophinopathy treatment and recommends that its anti-inflammatory and antioxidants properties in the dystrophic muscle should be better understood.

  6. Diaphragm and Lung Ultrasound to Predict Weaning Outcome: Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Llamas-Álvarez, Ana M; Tenza-Lozano, Eva M; Latour-Pérez, Jaime

    2017-12-01

    Deciding the optimal timing for extubation in patients who are mechanically ventilated can be challenging, and traditional weaning predictor tools are not very accurate. The aim of this systematic review and meta-analysis was to assess the accuracy of lung and diaphragm ultrasound for predicting weaning outcomes in critically ill adults. MEDLINE, the Cochrane Library, Web of Science, Scopus, LILACS, Teseo, Tesis Doctorales en Red, and OpenGrey were searched, and the bibliographies of relevant studies were reviewed. Two researchers independently selected studies that met the inclusion criteria and assessed study quality in accordance with the Quality Assessment of Diagnostic Accuracy Studies-2 tool. The summary receiver-operating characteristic curve and pooled diagnostic OR (DOR) were estimated by using a bivariate random effects analysis. Sources of heterogeneity were explored by using predefined subgroup analyses and bivariate meta-regression. Nineteen studies involving 1,071 people were included in the study. For diaphragm thickening fraction, the area under the summary receiver-operating characteristic curve was 0.87, and DOR was 21 (95% CI, 11-40). Regarding diaphragmatic excursion, pooled sensitivity was 75% (95% CI, 65-85); pooled specificity, 75% (95% CI, 60-85); and DOR, 10 (95% CI, 4-24). For lung ultrasound, the area under the summary receiver-operating characteristic curve was 0.77, and DOR was 38 (95% CI, 7-198). Based on bivariate meta-regression analysis, a significantly higher specificity for diaphragm thickening fraction and higher sensitivity for diaphragmatic excursion was detected in studies with applicability concerns. Lung and diaphragm ultrasound can help predict weaning outcome, but its accuracy may vary depending on the patient subpopulation. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  7. Investigation of geometric design in piezoelectric microelectromechanical systems diaphragms for ultrasonic energy harvesting

    Science.gov (United States)

    Shi, Qiongfeng; Wang, Tao; Kobayashi, Takeshi; Lee, Chengkuo

    2016-05-01

    Acoustic energy transfer (AET) has been widely used for contactless energy delivery to implantable devices. However, most of the energy harvesters (ultrasonic receivers) for AET are macro-scale transducers with large volume and limited operation bandwidth. Here, we propose and investigate two microelectromechanical systems diaphragm based piezoelectric ultrasonic energy harvesters (PUEHs) as an alternative for AET. The proposed PUEHs consist of micro-scale diaphragm array with different geometric parameter design. Diaphragms in PUEH-1 have large length to width ratio to achieve broadband property, while its energy harvesting performance is compromised. Diaphragms in PUEH-2 have smaller length to width ratio and thinner thickness to achieve both broadband property and good energy harvesting performance. Both PUEHs have miniaturized size and wide operation bandwidth that are ideally suitable to be integrated as power source for implantable biomedical devices. PUEH-1 has a merged -6 dB bandwidth of 74.5% with a central frequency of 350 kHz. PUEH-2 has two separate -6 dB bandwidth of 73.7%/30.8% with central frequencies of 285 kHz/650 kHz. They can adapt to various ultrasonic sources with different working frequency spectrum. Maximum output power is 34.3 nW and 84.3 nW for PUEH-1 and PUEH-2 at 1 mW/cm2 ultrasound intensity input, respectively. The associated power density is 0.734 μW/cm2 and 4.1 μW/cm2, respectively. Better energy harvesting performance is achieved for PUEH-2 because of the optimized length to width ratio and thickness design. Both PUEHs offer more alignment flexibility with more than 40% power when they are in the range of the ultrasound transmitter.

  8. X-ray and CT signs of connective tissue dysplasia in patients with primarily diagnosed infiltrative pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Sukhanova, L.A.; Sharmazanova, O.P.

    2009-01-01

    The x-ray signs of connective tissue systemic dysplasia (CTSD) in patients with primarily diagnosed pulmonary tuberculosis was investigated. Fifty-four patients (28 med and 26 women aged 18-70) with primarily diagnosed infiltrative pulmonary tuberculosis underwent x-ray study. In patients with infiltration pulmonary tuberculosis CTSD in the lungs manifests by their diminishing, deformity of the lung pattern, high position of the diaphragm cupola, mediastinum shift to the side of the pathology, which is better seen on CT. The degree of CTSD x-ray signs in the lungs depends on the number of phenotypical signs that is the degree of the disease manifestation. CT allows more accurate determining of the signs of connective tissue dysplasia in which tuberculosis develops

  9. Electromyographic activity of the diaphragm during neostigmine or sugammadex-enhanced recovery after neuromuscular blockade with rocuronium: a randomised controlled study in healthy volunteers.

    Science.gov (United States)

    Schepens, Tom; Cammu, Guy; Saldien, Vera; De Neve, Nikolaas; Jorens, Philippe G; Foubert, Luc; Vercauteren, Marcel

    2015-01-01

    The use of neuromuscular blocking agents has been associated with severe postoperative respiratory morbidity. Complications can be attributed to inadequate reversal, and reversal agents may themselves have adverse effects. To compare the electromyographic activity of the diaphragm (EMGdi) during recovery from neuromuscular blockade using neostigmine and sugammadex. The hypothesis was that there would be better neuromuscular coupling of the diaphragm when sugammadex was used. A randomised, controlled, parallel-group, single-centre, double-blinded study. District general hospital in Belgium. Twelve healthy male volunteers. Individuals were anaesthetised with propofol and remifentanil. After rocuronium 0.6 mg kg, a transoesophageal electromyography (EMG) recorder was inserted. For reversal of neuromuscular blockade, volunteers received sugammadex 2 mg kg (n = 6) or neostigmine 70 μg kg (n = 6). EMGdi, airway pressure and flow were continuously measured during weaning from the ventilator until tracheal extubation. Arterial blood gas samples were obtained for PaO2 and PaCO2 analysis at the first spontaneous breathing attempt and after tracheal extubation. During weaning, 560 breaths were retained for analysis. The median (95% CI) peak EMGdi was 1.1 (0.9 to 1.5) μV in the neostigmine group and 1.6 (1.3 to 1.9) μV in the sugammadex group (P sugammadex group (P = 0.008). The median (95% CI) tidal volume was 287 (256 to 335) ml after neostigmine and 359 (313 to 398) ml after sugammadex (P = 0.013). The median (95% CI) PaO2 immediately after extubation was 30.5 (22.8 to 37.1) kPa after sugammadex vs. 20.7 (12.9 to 27.5) kPa after neostigmine (P = 0.03). EMGdi, tidal volume and PaO2 following tracheal extubation were increased after sugammadex compared with neostigmine, reflecting diaphragm-driven inspiration after sugammadex administration. Sugammadex may free more diaphragmatic acetylcholine receptors than neostigmine, which has an

  10. Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT

    International Nuclear Information System (INIS)

    Weiss, Elisabeth; Wijesooriya, Krishni; Dill, S. Vaughn; Keall, Paul J.

    2007-01-01

    Purpose: To investigate temporospatial variations of tumor and normal tissue during respiration in lung cancer patients. Methods and Materials: In 14 patients, gross tumor volume (GTV) and normal tissue structures were manually contoured on four-dimensional computed tomography (4D-CT) scans. Structures were evaluated for volume changes, centroid (center of mass) motion, and phase dependence of variations relative to inspiration. Only volumetrically complete structures were used for analysis (lung in 2, heart in 8, all other structures in >10 patients). Results: During respiration, the magnitude of contoured volumes varied up to 62.5% for GTVs, 25.5% for lungs, and 12.6% for hearts. The range of maximum three-dimensional centroid movement for individual patients was 1.3-24.0 mm for GTV, 2.4-7.9 mm for heart, 5.2-12.0 mm for lungs, 0.3-5.5 mm for skin markers, 2.9-10.0 mm for trachea, and 6.6-21.7 mm for diaphragm. During respiration, the centroid positions of normal structures varied relative to the centroid position of the respective GTV by 1.5-8.1 mm for heart, 2.9-9.3 mm for lungs, 1.2-9.2 mm for skin markers, 0.9-7.1 mm for trachea, and 2.7-16.4 mm for diaphragm. Conclusion: Using 4D-CT, volumetric changes, positional alterations as well as changes in the position of contoured structures relative to the GTV were observed with large variations between individual patients. Although the interpretation of 4D-CT data has considerable uncertainty because of 4D-CT artifacts, observer variations, and the limited acquisition time, the findings might have a significant impact on treatment planning

  11. Comparison of clinical utility between diaphragm excursion and thickening change using ultrasonography to predict extubation success

    Science.gov (United States)

    Yoo, Jung-Wan; Lee, Seung Jun; Lee, Jong Deog; Kim, Ho Cheol

    2018-01-01

    Background/Aims Both diaphragmatic excursion and change in muscle thickening are measured using ultrasonography (US) to assess diaphragm function and mechanical ventilation weaning outcomes. However, which parameter can better predict successful extubation remains to be determined. The aim of this study was to compare the clinical utility of these two diaphragmatic parameters to predict extubation success. Methods This study included patients subjected to extubation trial in the medical or surgical intensive care unit of a university-affiliated hospital from May 2015 through February 2016. Diaphragm excursion and percent of thickening change (Δtdi%) were measured using US within 24 hours before extubation. Results Sixty patients were included, and 78.3% (47/60) of these patients were successfully extubated, whereas 21.7% (13/60) were not. The median degree of excursion was greater in patients with extubation success than in those with extubation failure (1.65 cm vs. 0.8 cm, p success had a greater Δtdi% than those with extubation failure (42.1% vs. 22.5%, p = 0.03). The areas under the receiver operating curve for excursion and Δtdi% were 0.836 (95% confidence interval [CI], 0.717 to 0.919) and 0.698 (95% CI, 0.566 to 0.810), respectively (p = 0.017). Conclusions Diaphragm excursion seems more accurate than a change in the diaphragm thickness to predict extubation success. PMID:29050461

  12. Localized-low attenuation of the lung on thin-section CT in experimentally induced pulmonary arterial occlusion with balloon catheter in pigs

    International Nuclear Information System (INIS)

    Lee, Hyun Ju; Goo, Jin Mo; Im, Jung Gi; Kim, Ji Hye

    2008-01-01

    To determine whether a localized low-attenuation (LLA) is induced on a thin-section CT (TSCT) during an acute pulmonary arterial occlusion in pigs. In eight pigs, 14 sites of the descending pulmonary artery were obstructed using balloon catheters. The lung TSCTs were obtained immediately after pulmonary artery obstruction (n=13), 10 min (n=10), 30 min (n=14) and 60 min (n=14) after pulmonary artery obstruction at the end of expiration. The TSCTs were also obtained after balloon-deflation at the end of expiration (n=11) and with the balloon-reinflation at inspiration (n=6). Of the 14 sites of pulmonary artery obstruction, 11 (79%) showed LLA. However, LLA progressively became fainter or disappeared on a follow-up CT in seven sites. When the balloon was deflated, 10 of the 11 sites measured showed no change in lung attenuation. After full inspiration, LLA disappeared in three of the six sites. The corresponding areas of LLA on the CT showed a statistically significant increase compared to the baseline CT immediately after inflation (ρ =0.021) and 30 minutes after inflation (ρ = 0.041), and after balloon deflation (ρ = 0.036). LLA was induced by acute pulmonary artery obstruction. However, LLA, gradually faded over the 60 minutes following obstruction. LLAs were maintained despite the restoration of pulmonary arterial flow, but disappeared as a result of a full inspiration. Thus, LLA might be caused by air trapping

  13. Automatic assessment of average diaphragm motion trajectory from 4DCT images through machine learning.

    Science.gov (United States)

    Li, Guang; Wei, Jie; Huang, Hailiang; Gaebler, Carl Philipp; Yuan, Amy; Deasy, Joseph O

    2015-12-01

    To automatically estimate average diaphragm motion trajectory (ADMT) based on four-dimensional computed tomography (4DCT), facilitating clinical assessment of respiratory motion and motion variation and retrospective motion study. We have developed an effective motion extraction approach and a machine-learning-based algorithm to estimate the ADMT. Eleven patients with 22 sets of 4DCT images (4DCT1 at simulation and 4DCT2 at treatment) were studied. After automatically segmenting the lungs, the differential volume-per-slice (dVPS) curves of the left and right lungs were calculated as a function of slice number for each phase with respective to the full-exhalation. After 5-slice moving average was performed, the discrete cosine transform (DCT) was applied to analyze the dVPS curves in frequency domain. The dimensionality of the spectrum data was reduced by using several lowest frequency coefficients ( f v ) to account for most of the spectrum energy (Σ f v 2 ). Multiple linear regression (MLR) method was then applied to determine the weights of these frequencies by fitting the ground truth-the measured ADMT, which are represented by three pivot points of the diaphragm on each side. The 'leave-one-out' cross validation method was employed to analyze the statistical performance of the prediction results in three image sets: 4DCT1, 4DCT2, and 4DCT1 + 4DCT2. Seven lowest frequencies in DCT domain were found to be sufficient to approximate the patient dVPS curves ( R = 91%-96% in MLR fitting). The mean error in the predicted ADMT using leave-one-out method was 0.3 ± 1.9 mm for the left-side diaphragm and 0.0 ± 1.4 mm for the right-side diaphragm. The prediction error is lower in 4DCT2 than 4DCT1, and is the lowest in 4DCT1 and 4DCT2 combined. This frequency-analysis-based machine learning technique was employed to predict the ADMT automatically with an acceptable error (0.2 ± 1.6 mm). This volumetric approach is not affected by the presence of the lung tumors

  14. Thin-section CT of the skull base

    International Nuclear Information System (INIS)

    Beyer-Enke, S.A.; Goerich, J.; Gamroth, A.; Tiedemann, K.

    1987-01-01

    High-resolution CT-images of the skull base are depicted and anatomical structures are described. A large variety of osseous and soft tissue structures can be differentiated in the temporal bone, nasopharynx and orbita. Knowledge of the anatomical structures is essential for the recognition of pathological changes and also plays an essential role for the diagnostically involved radiologist. (orig.) [de

  15. Rupture traumatique du diaphragme au CHU Gabriel Touré de ...

    African Journals Online (AJOL)

    Rupture traumatique du diaphragme au CHU Gabriel Touré de Bamako, Mali. B T Dembélé, A Togo, A Traoré, Y Sidibé, M Konaté, A A Traoré, A Bah, T Koné, I Tounkara, L Kanté, I Diakité, B Karembé, A Koné, M.I Mangane, G Diallo ...

  16. Functional restoration of the paralyzed diaphragm in high cervical quadriplegia via phrenic nerve neurotization utilizing the functional spinal accessory nerve.

    Science.gov (United States)

    Yang, Ming-liang; Li, Jian-jun; Zhang, Shao-cheng; Du, Liang-jie; Gao, Feng; Li, Jun; Wang, Yu-ming; Gong, Hui-ming; Cheng, Liang

    2011-08-01

    The authors report a case of functional improvement of the paralyzed diaphragm in high cervical quadriplegia via phrenic nerve neurotization using a functional spinal accessory nerve. Complete spinal cord injury at the C-2 level was diagnosed in a 44-year-old man. Left diaphragm activity was decreased, and the right diaphragm was completely paralyzed. When the level of metabolism or activity (for example, fever, sitting, or speech) slightly increased, dyspnea occurred. The patient underwent neurotization of the right phrenic nerve with the trapezius branch of the right spinal accessory nerve at 11 months postinjury. Four weeks after surgery, training of the synchronous activities of the trapezius muscle and inspiration was conducted. Six months after surgery, motion was observed in the previously paralyzed right diaphragm. The lung function evaluation indicated improvements in vital capacity and tidal volume. This patient was able to sit in a wheelchair and conduct outdoor activities without assisted ventilation 12 months after surgery.

  17. Mycobacterium avium subsp. avium in lymph nodes and diaphragms of pigs from one infected herd in the Czech Republic.

    Science.gov (United States)

    Kriz, Petr; Kaevska, Marija; Slana, Iva; Bartejsova, Iva; Pavlik, Ivo

    2014-01-01

    This study was performed on 40 finished pigs from one herd naturally infected with Mycobacterium avium subsp. avium. The aim was to investigate the presence and amount of M. a. avium in samples of lymph nodes and diaphragm tissues collected during routine postmortem inspection using the triplex quantitative real time PCR (qPCR) method. We collected, in total, 107 samples: various lymph nodes affected by gross tuberculosis (TB)-like lesions from 17 pig carcasses, as well as samples of head and mesenteric lymph nodes from 23 carcasses without TB-like lesions. Samples of diaphragm tissues were collected from all carcasses. M. a. avium was detected in one or more tissue samples collected from half of the slaughtered pigs tested. Samples of diaphragm tissues of three pigs with detected TB-like lesions contained M. a. avium (10(2) to 10(3) cells per g of sample); the organism was not detected in diaphragm tissues from pigs without TB-like lesions. The qPCR method may be useful for quantification of M. a. avium in pigs for the purposes of foodborne risk assessment.

  18. Numerical Analysis of Diaphragm Wall Model Executed in Poznań Clay Formation Applying Selected Fem Codes

    Directory of Open Access Journals (Sweden)

    Superczyńska M.

    2016-09-01

    Full Text Available The paper presents results of numerical calculations of a diaphragm wall model executed in Poznań clay formation. Two selected FEM codes were applied, Plaxis and Abaqus. Geological description of Poznań clay formation in Poland as well as geotechnical conditions on construction site in Warsaw city area were presented. The constitutive models of clay implemented both in Plaxis and Abaqus were discussed. The parameters of the Poznań clay constitutive models were assumed based on authors’ experimental tests. The results of numerical analysis were compared taking into account the measured values of horizontal displacements.

  19. Method of production of a diaphragm for instruments in particle optics and diaphragm fabricated by this method

    International Nuclear Information System (INIS)

    Sandrik, J.; Krohne, P.

    1975-01-01

    The production method of, e.g., a circular diaphragm for an electron microscope is based on copper plate as supporting material. A light-sensitive, electrically insulating layer is coated on this. After exposing and freeing the positions of this layer, e.g., the circular interior as well as the cross-piece to the exterior of the diaghragm, a galvanic building-up of a noble metal layer follows, e.g. gold, on these now free positions. After freeing the remaining non-exposed material, an etching-protective lacquer is coated on the positions of the supporting material which are to be maintained. The remaining parts of the supporting material are then removed by positive etching. (DG/LH) [de

  20. Hydrophil diaphragms on the basis of perfluorated copolymers FEP and polyacryl nitrile: Manufacture by radiation- initiated grafting and their use for pervaporation

    International Nuclear Information System (INIS)

    Scholz, H.

    1986-01-01

    The radiation-initiated grafting copolymerisation of hydrophil monomers to FEP, a copolymer of tetrafluorethene and hexafluorpropene and to polyacryl nitrile (PAN) was examined in this dissertation. The grafted products were used as diaphragms for the separation of water-ethanol mixtures by pervaporation. Water was separated through the diaphragm from the mixture in the pervaporation experiments. It was shown how the mechanical properties of the basic polymer affect the interaction between basic polymer and grafted polymer and how the grafting conditions affect the diaphragm properties. By grafting acrylic acid on to the basic polymers FEP and PAN, very good results were achieved for the water-ethanol separation, if the diaphragms were used in the K form. The selectivity of PAN-g-acrylic acid-K for water reached values of α > 1000. (orig./RB) [de

  1. Bending-induced electromechanical coupling and large piezoelectric response in a micromachined diaphragm

    KAUST Repository

    Wang, Zhihong; Yao, Yingbang; Wang, Xianbin; Yue, Weisheng; Chen, Longqing; Zhang, Xixiang

    2013-01-01

    We investigated the dependence of electromechanical coupling and the piezoelectric response of a micromachined Pb(Zr 0.52 Ti 0.48)O 3 (PZT) diaphragm on its curvature by observing the impedance spectrum and central deflection responses to a small AC

  2. Functional assessment of the diaphragm by speckle tracking ultrasound during inspiratory loading

    NARCIS (Netherlands)

    Mos-Oppersma, Eline; Hatam, Nima; Doorduin, Jonne; van der Hoeven, Johannes G.; Marx, Gernot; Goetzenich, Andreas; Fritsch, Sebastian; Heunks, Leo M.A.; Bruells, Christian S.

    2017-01-01

    Assessment of diaphragmatic effort is challenging, especially in critically ill patients in the phase of weaning. Fractional thickening during inspiration assessed by ultrasound has been used to estimate diaphragm effort. It is unknown whether more sophisticated ultrasound techniques such as speckle

  3. Evaluation of bubbler/diaphragm techniques to measure surface level in the waste storage tanks

    International Nuclear Information System (INIS)

    Peters, T.J.; Hickman, B.J.; Colson, J.B.

    1993-10-01

    This report describes the results of tests conducted at the Pacific Northwest Laboratory (PNL) to determine if a bubbler technique can be used to determine the surface level in the waste tanks. Two techniques were evaluated. The first technique is a standard bubbler system in which a tube is placed below the surface of the liquid to be measured and air pressure inside a tube is increased until bubbles begin to become emitted from the tube. The air pressure then is a function of the pressure at the bottom of the tube. The second technique involves a system similar to the standard bubbler technique, but instead of bubbles being released into the material to be gauged, air pressure is increased against a diaphragm until enough pressure is applied to overcome the pressure of the liquid at the given depth, at which time the air then flows in a return loop back to a vent. The advantage of the diaphragm system is that it is a sealed system; thus no air is released into the waste tank materials, and it is not possible for the waste tank materials to get into the air flow. Based on the results of the tests conducted in this program, it appears that the bubbler and diaphragm systems that were tested could not be used for accurate measurements of the level in the waste tanks. Both exhibited deposits of simulated waste tank material at the end of the devices which affected the ability of the gauge to accurately determine changes in the surface level even though the measured value of the level was inaccurate. Further investigations into the cause of this inaccuracy may be warranted. Alternate diaphragm materials may improve the performance of this gauge

  4. Enhanced dual-phase spiral CT features of polypoid ampullary carcinoma

    International Nuclear Information System (INIS)

    Zeng Mengsu; Yan Fuhua; Zhou Kangrong; Chen Huiming; Chen Gang; Chen Jin

    2001-01-01

    Objective: To understand CT features of polypoid ampullary carcinoma by enhanced dual-phase spiral CT. Methods: 15 cases of polypoid ampullary carcinoma (PAC) confirmed by surgical and pathological results were studied with thin slice enhanced dual-phase spiral CT (including arterial and portal phase scanning)with retrospective analysis, the scanning parameters were 5 mm thickness and 1.0 pitch for arterial phase scanning, and 5 mm thickness and 5 mm space for portal phase scanning. Results: All cases could display an enhanced mass as local filling defect at the site of the duodenal Vater's ampulla during arterial and portal phase scanning, the tumors ranged in size from 1 cm to 5 cm with mean of 2.3 cm, all were accompanied with dilated intrahepatic and common bile duct, enlarged gallbladder and dilated pancreatic duct, except one case which had marked atrophy of the pancreatic body and tail. Conclusion: The thin slices enhanced dual-phase spiral CT could not only accurately define the level of obstruction, but also demonstrate an enhanced mass as direct CT sign of the PAC, which is crucial for diagnosis of the PAC

  5. Branchial cleft anomalies: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Seok, Eul Hye; Park, Chan Sup [College of Medicine, Inha University, Seongnam (Korea, Republic of)

    1994-04-15

    The purpose of this paper is to describe the CT findings of a variety of branchial cleft anomalies in the head and neck area. We reviewed the CT findings of 16 patients with neck lesion pathologically proved as branchial cleft anomalies. There were two first and 12 second branchial cleft cysts, one first and one second branchial cleft sinuses. Two cases of first branchial cleft cysts were manifested as thin-walled, cystic masses at auricular area. One first branchial cleft sinus was an external opening type and manifested as an ill-defined, enhancing solid lesion at posterior auricular area. All 12 cases of second branchial cleft cysts demonstrated a typical location, displacing the sternocleidomastoid muscle posteriorly, the carotid artery and internal jugular vein complex medially and the submandibular gland anteriorly. Eight cases of second branchial cleft cysts were seen as fluid-filled, round or ovoid-shaped cysts, and 3 cases of them were seen as irregular-shaped cysts. In one case, suppurative adenopathy with loss of soft tissue planes around the cyst was observed. One case of second branchial cleft sinus was manifested as a tubular-shaped, enhancing lesion at submental area and containing external opening site draining into the anterior border of the sternocleidomastoid muscle. We conclude that CT provides important diagnostic and therapeutic information in patients with a neck mass believed to be a branchial cleft anomaly, as it can differentiate various forms of the branchial anomalies by their characteristic location and shape.

  6. Branchial cleft anomalies: CT evaluation

    International Nuclear Information System (INIS)

    Seok, Eul Hye; Park, Chan Sup

    1994-01-01

    The purpose of this paper is to describe the CT findings of a variety of branchial cleft anomalies in the head and neck area. We reviewed the CT findings of 16 patients with neck lesion pathologically proved as branchial cleft anomalies. There were two first and 12 second branchial cleft cysts, one first and one second branchial cleft sinuses. Two cases of first branchial cleft cysts were manifested as thin-walled, cystic masses at auricular area. One first branchial cleft sinus was an external opening type and manifested as an ill-defined, enhancing solid lesion at posterior auricular area. All 12 cases of second branchial cleft cysts demonstrated a typical location, displacing the sternocleidomastoid muscle posteriorly, the carotid artery and internal jugular vein complex medially and the submandibular gland anteriorly. Eight cases of second branchial cleft cysts were seen as fluid-filled, round or ovoid-shaped cysts, and 3 cases of them were seen as irregular-shaped cysts. In one case, suppurative adenopathy with loss of soft tissue planes around the cyst was observed. One case of second branchial cleft sinus was manifested as a tubular-shaped, enhancing lesion at submental area and containing external opening site draining into the anterior border of the sternocleidomastoid muscle. We conclude that CT provides important diagnostic and therapeutic information in patients with a neck mass believed to be a branchial cleft anomaly, as it can differentiate various forms of the branchial anomalies by their characteristic location and shape

  7. Energy loss in electrochemical diaphragm process of chlorine and alkali industry - A collateral effect of the undesirable generation of chlorate

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Phabyanno Rodrigues; Mirapalheta, Almir; e Silva Zanta, Carmem Lucia de Paiva; Tonholo, Josealdo [Instituto de Quimica e Biotecnologia, Universidade Federal de Alagoas, 57072970 Maceio, AL (Brazil); Henrique dos Santos Andrade, Marcio [Instituto de Quimica e Biotecnologia, Universidade Federal de Alagoas, 57072970 Maceio, AL (Brazil); Braskem S/A, Maceio, AL (Brazil); Vilar, Eudesio Oliveira [Departamento de Engenharia Quimica, Universidade Federal de Campina, Grande, Campina Grande, PB (Brazil)

    2010-05-15

    Contamination of NaOH with chlorate constitutes a major problem for the chlorine-alkali industry, particularly when electrolytic cells based on the diaphragm process are employed. In this paper, pilot and laboratory cell experiments revealed that chlorate contamination in diaphragm cells also inhibits hydrogen evolution and gives rise to a significant increase in electrical energy consumption. Electrolysis carried out under conditions that simulated the industrial process (current density 240 mA cm{sup -2}; temperature 90 C; brine flux 23 L cm{sup -2} h{sup -1}) revealed that chlorate formation depends on brine flux and NaOH production. The inhibitory effect of chlorate on the main cathodic reaction was demonstrated in bench cell experiments, with cathodic displacement of the hydrogen evolution reaction by more than 100 mV in the presence of 0.4% chlorate compared with ideal conditions in which chlorate formation was absent. This hydrogen generation overpotential can charge the total electric energy balance in more than 5% of the total value, consisting of a critical loss for this process. (author)

  8. Peak broadening in paper chromatography and related techniques VI. The efficiency of various kinds of chromatography paper and thin-layer cellulose powder for the separation of amino acids

    NARCIS (Netherlands)

    Ligny, C.L. de; Kok, E.C.M.

    1968-01-01

    The efficiency of several chromatography papers and thin-layer cellulose powders for the separation of amino acids is investigated, using the minimum elution time for a given resolution as the criterion.

  9. The CT signs of intestinal volvulus

    International Nuclear Information System (INIS)

    Ji Jiansong; Wang Zufei; Xu Zhaolong; Lv Guijian; Xu Min; Zhao Zhongwei; Su Jinliang; Zhou Limin

    2005-01-01

    Objective: To improve the accuracy rate of spiral CT diagnosing intestinal volvulus. Methods: To analysis the CT findings of 9 cases of intestinal volvulus proved by operation, the main reconstruction techniques were multiplanar reformation (MPR) and sliding thin-slab maximum intensity projection (STS-MIP). Results: All the 9 cases were diagnosed accurately, the main signs were 'whirlpool' of intestine (6 cases) and vessels (9 cases),'target loop' (2 cases),'beak'(6 cases). Conclusion: 'Whirlpool' of vessels is a specific sign to diagnose intestinal volvulus, 'target loop', reduced enhancement of intestinal wall and ascites are the reliable signs to strangulated intestinal obstruction. Spiral CT and reconstructions have important value to diagnose the intestinal volvulus. (authors)

  10. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    International Nuclear Information System (INIS)

    Lim, Kun Young; Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi; Seo, Joon Beom

    2006-01-01

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images (ρ < 0.01). Agreement was fair between two observers (κ = 0.38, ρ < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens

  11. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Kun Young [National Cancer Center, Goyang (Korea, Republic of); Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi [Seoul National University Hospital and the Institute of Radiation Medicine, Seoul (Korea, Republic of); Seo, Joon Beom [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2006-05-15

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images ({rho} < 0.01). Agreement was fair between two observers ({kappa} = 0.38, {rho} < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens.

  12. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    International Nuclear Information System (INIS)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung

    1987-01-01

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed

  13. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1987-06-15

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed.

  14. Evaluation of solitary pulmonary metastasis of extrathoracic tumor with thin-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shiotani, Seiji; Yamada, Kouzo; Oshita, Fumihiro; Nomura, Ikuo; Noda, Kazumasa; Yamagata, Tatushi; Tajiri, Michihiko; Ishibashi, Makoto; Kameda, Youichi [Kanagawa Cancer Center, Yokohama (Japan)

    1995-10-01

    Thin-slice computed tomography (CT) images were compared with pathological findings in 9 specimens of solitary pulmonary nodules, which had been pathologically diagnosed as pulmonary metastasis of extrathoracic tumor. The thin-slice CT images were 2 mm-thick images reconstructed using a TCT-900S, HELIX (Toshiba, Tokyo) and examined at two different window and level settings. In every case, the surgical specimens were sliced transversely to correlate with the CT images. According to the image findings, the internal structure was of the solid-density type in every case, and the margin showed spiculation in 22%, notching in 67% and pleural indentation in 89%. Regarding the relationship between the pulmonary vessels and tumors, plural vascular involvement was revealed in every case. Thus, it was difficult to distinguish solitary pulmonary metastasis of extrathoracic tumor from primary lung cancer based on the thin-slice CT images. For some solitary pulmonary metastasis of extrathoracic tumor, a comprehensive diagnostic approach taking both the anamnesis and pathological findings into consideration was required. (author).

  15. Developmental plasticity of phrenic motoneuron and diaphragm properties with the inception of inspiratory drive transmission in utero.

    Science.gov (United States)

    Greer, John J; Martin-Caraballo, Miguel

    2017-01-01

    The review outlines data consistent with the hypothesis that inspiratory drive transmission that generates fetal breathing movements (FBMs) is essential for the developmental plasticity of phrenic motoneurons (PMNs) and diaphragm musculature prior to birth. A systematic examination during the perinatal period demonstrated a very marked transformation of PMN and diaphragm properties coinciding with the onset and strengthening of inspiratory drive and FBMs in utero. This included studies of age-dependent changes of: i) morphology, neuronal coupling, passive and electrophysiological properties of PMNs; ii) rhythmic inspiratory activity in vitro; iii) FBMs generated in vivo detected by ultrasonography; iv) contractile and end-plate potential properties of diaphragm musculature. We also propose how the hypothesis can be further evaluated with studies of perinatal hypoglossal motoneuron-tongue musculature and the use of Dbx1 null mice that provide an experimental model lacking descending inspiratory drive transmission in utero. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Development of a Hemispherical Metal Diaphragm for Single-Cycle Liquid-Metal Positive Expulsion Systems

    National Research Council Canada - National Science Library

    Gorland, Sol

    1965-01-01

    This report presents experimental results pertaining to the design and development of a metallic expulsion diaphragm for single-cycle positive expulsion of high-temperature liquid in an agravity condition...

  17. Oxidative damage induced by cigarette smoke exposure in mice: impact on lung tissue and diaphragm muscle,

    Directory of Open Access Journals (Sweden)

    Samanta Portão de Carlos

    2014-08-01

    Full Text Available OBJECTIVE: To evaluate oxidative damage (lipid oxidation, protein oxidation, thiobarbituric acid-reactive substances [TBARS], and carbonylation and inflammation (expression of phosphorylated AMP-activated protein kinase and mammalian target of rapamycin [p-AMPK and p-mTOR, respectively] in the lung parenchyma and diaphragm muscles of male C57BL-6 mice exposed to cigarette smoke (CS for 7, 15, 30, 45, or 60 days. METHODS: Thirty-six male C57BL-6 mice were divided into six groups (n = 6/group: a control group; and five groups exposed to CS for 7, 15, 30, 45, and 60 days, respectively. RESULTS: Compared with control mice, CS-exposed mice presented lower body weights at 30 days. In CS-exposed mice (compared with control mice, the greatest differences (increases in TBARS levels were observed on day 7 in diaphragm-muscle, compared with day 45 in lung tissue; the greatest differences (increases in carbonyl levels were observed on day 7 in both tissue types; and sulfhydryl levels were lower, in both tissue types, at all time points. In lung tissue and diaphragm muscle, p-AMPK expression exhibited behavior similar to that of TBARS. Expression of p-mTOR was higher than the control value on days 7 and 15 in lung tissue, as it was on day 45 in diaphragm muscle. CONCLUSION: Our data demonstrate that CS exposure produces oxidative damage, not only in lung tissue but also (primarily in muscle tissue, having an additional effect on respiratory muscle, as is frequently observed in smokers with COPD.

  18. Method of producing the arched surfaces of diaphragm rings for large containers, especially for prestressed-concrete pressure vessels of nuclear reactors

    International Nuclear Information System (INIS)

    Kumpf, H.

    1976-01-01

    In producing arched surfaces of diaphragm rings for large containers, especially for prestressed-concrete pressure vessels for nuclear power plants, it is of advantage to manufacture these directly on the construction site. According to the invention the, at first level, diaphragm ring is put on the predetermined place, sectionally pressed against and shaped by a shaping tool - with a profiled supporting ring as a counter-acting tool - and afterwards welded together with the annular wall sections of the large container along the shaped parts. The manufacture of single and double configurations of diaphragm rings is described. It is of advantage if shaping and mounting position coincide. (UWI) [de

  19. Fast and Automatic Ultrasound Simulation from CT Images

    Directory of Open Access Journals (Sweden)

    Weijian Cong

    2013-01-01

    Full Text Available Ultrasound is currently widely used in clinical diagnosis because of its fast and safe imaging principles. As the anatomical structures present in an ultrasound image are not as clear as CT or MRI. Physicians usually need advance clinical knowledge and experience to distinguish diseased tissues. Fast simulation of ultrasound provides a cost-effective way for the training and correlation of ultrasound and the anatomic structures. In this paper, a novel method is proposed for fast simulation of ultrasound from a CT image. A multiscale method is developed to enhance tubular structures so as to simulate the blood flow. The acoustic response of common tissues is generated by weighted integration of adjacent regions on the ultrasound propagation path in the CT image, from which parameters, including attenuation, reflection, scattering, and noise, are estimated simultaneously. The thin-plate spline interpolation method is employed to transform the simulation image between polar and rectangular coordinate systems. The Kaiser window function is utilized to produce integration and radial blurring effects of multiple transducer elements. Experimental results show that the developed method is very fast and effective, allowing realistic ultrasound to be fast generated. Given that the developed method is fully automatic, it can be utilized for ultrasound guided navigation in clinical practice and for training purpose.

  20. Concrete Flow in Diaphragm Wall Panels : A Full-Scale In-Situ Test

    NARCIS (Netherlands)

    Van Dalen, J.H.; Bosch, J.W.; Broere, W.

    2015-01-01

    Flow processes, taking place during the concreting of diaphragm wall panels (D-wall panels), are of great importance for the quality of the wall. During this phase, the bentonite, present in the excavated trench, should be completely replaced by concrete in a controlled way. In literature several

  1. Secure thin client architecture for DICOM image analysis

    Science.gov (United States)

    Mogatala, Harsha V. R.; Gallet, Jacqueline

    2005-04-01

    This paper presents a concept of Secure Thin Client (STC) Architecture for Digital Imaging and Communications in Medicine (DICOM) image analysis over Internet. STC Architecture provides in-depth analysis and design of customized reports for DICOM images using drag-and-drop and data warehouse technology. Using a personal computer and a common set of browsing software, STC can be used for analyzing and reporting detailed patient information, type of examinations, date, Computer Tomography (CT) dose index, and other relevant information stored within the images header files as well as in the hospital databases. STC Architecture is three-tier architecture. The First-Tier consists of drag-and-drop web based interface and web server, which provides customized analysis and reporting ability to the users. The Second-Tier consists of an online analytical processing (OLAP) server and database system, which serves fast, real-time, aggregated multi-dimensional data using OLAP technology. The Third-Tier consists of a smart algorithm based software program which extracts DICOM tags from CT images in this particular application, irrespective of CT vendor's, and transfers these tags into a secure database system. This architecture provides Winnipeg Regional Health Authorities (WRHA) with quality indicators for CT examinations in the hospitals. It also provides health care professionals with analytical tool to optimize radiation dose and image quality parameters. The information is provided to the user by way of a secure socket layer (SSL) and role based security criteria over Internet. Although this particular application has been developed for WRHA, this paper also discusses the effort to extend the Architecture to other hospitals in the region. Any DICOM tag from any imaging modality could be tracked with this software.

  2. Chest CT study of patients with asbestos exposure, 1

    International Nuclear Information System (INIS)

    Hatakeyama, Masayuki

    1988-01-01

    Thin-slice high-resolution computed tomographic (CT) findings of 36 patients (34 men, 2 women) with histories of long-term (11 to 43 years) occupational asbestos exposure (AS) were analyzed for pulmonary abnormalities, which were classified by the subpleural curvilinear shadow (SCLS) and/or the extent of honeycomb shadow (HS) into five types (O to IV). SCLS was detected in 22 patients (62 %), and HS in 14 patients (39 %). SCLS was distributed mainly in the lower lobe in patients with mild pulmonary fibrosis (Types I and II) and in segments where fibrosis was mild in patients with HS (Types III and IV). This may reflect the initiation of pulmonary fibrosis leading to the formation of a HS. Most (63.7 %) SCLS measured > 5 cm but < 10 cm in length and occurred < 1 cm from the inner chest wall in all cases. Radiologic-pathologic correlation of SCLS and HS in CT imagings, achieved in two post mortem specimens, seemed to indicate that SCLS was associated with the initial change of fibrosing bronchiolo-alveolitis, which is characteristic of pulmonary asbestosis. Thin-slice high-resolution CT findings of 36 patients with AS and 33 patients with idiopathic interstitial pneumonia (IIP) were compared. Though the incidence of SCLS was low (21 %) in this series of IIP, its presence suggests that SCLS is not specific to pulmonary asbestosis but occurs also in chronic interstitial pneumonia. In order to explore the mechanism of the appearance of SCLS, further analysis of CT and histopathologic findings not only of pulmonary asbestosis and IIP but also of many other pulmonary interstitial diseases is necessary. It could be considered that thin-slice high-resolution CT which first detected SCLS is very useful in the visualization of fine structures of the lungs. (author)

  3. Fabrication of TiO2/EP super-hydrophobic thin film on filter paper surface.

    Science.gov (United States)

    Gao, Zhengxin; Zhai, Xianglin; Liu, Feng; Zhang, Ming; Zang, Deli; Wang, Chengyu

    2015-09-05

    A composite filter paper with super-hydrophobicity was obtained by adhering micro/nano structure of amorphous titanium dioxide on the filter paper surface with modifying low surface energy material. By virtue of the coupling agent, which plays an important part in bonding amorphous titanium dioxide and epoxy resin, the structure of super-hydrophobic thin film on the filter paper surface is extremely stable. The microstructure of super-hydrophobic filter paper was characterized by scanning electron microscopy (SEM), the images showed that the as-prepared filter paper was covered with uniform amorphous titanium dioxide particles, generating a roughness structure on the filter paper surface. The super-hydrophobic performance of the filter paper was characterized by water contact angle measurements. The observations showed that the wettability of filter paper samples transformed from super-hydrophilicity to super-hydrophobicity with the water contact angle of 153 ± 1°. Some experiments were also designed to test the effect of water-oil separation and UV-resistant by the super-hydrophobic filter paper. The prepared super-hydrophobic filter paper worked efficiently and simply in water-oil separation as well as enduringly in anti-UV property after the experiments. This method offers an opportunity to the practical applications of the super-hydrophobic filter paper. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Right diaphragmatic rupture and hepatic hernia: an indirect sign on computed tomography

    International Nuclear Information System (INIS)

    Sadeghi, N.; Nicaise, N.; Struyven, J.; Gansbeke, D. van; DeBacker, D.

    1999-01-01

    We report a case of blunt traumatic right diaphragm rupture with hepatic hernia. The diagnosis was first suggested by an abnormal hepatic location depicted on axial CT. This finding can be considered as a potentially new indirect sign of right diaphragm rupture in patients with blunt trauma. The diagnosis was then confirmed by reformatted CT and MR images. (orig.)

  5. Quantifying oxygen in paper-based cell cultures with luminescent thin film sensors.

    Science.gov (United States)

    Boyce, Matthew W; Kenney, Rachael M; Truong, Andrew S; Lockett, Matthew R

    2016-04-01

    Paper-based scaffolds are an attractive material for generating 3D tissue-like cultures because paper is readily available and does not require specialized equipment to pattern, cut, or use. By controlling the exchange of fresh culture medium with the paper-based scaffolds, we can engineer diffusion-dominated environments similar to those found in spheroids or solid tumors. Oxygen tension directly regulates cellular phenotype and invasiveness through hypoxia-inducible transcription factors and also has chemotactic properties. To date, gradients of oxygen generated in the paper-based cultures have relied on cellular response-based readouts. In this work, we prepared a luminescent thin film capable of quantifying oxygen tensions in apposed cell-containing paper-based scaffolds. The oxygen sensors, which are polystyrene films containing a Pd(II) tetrakis(pentafluorophenyl)porphyrin dye, are photostable, stable in culture conditions, and not cytotoxic. They have a linear response for oxygen tensions ranging from 0 to 160 mmHg O2, and a Stern-Volmer constant (K sv) of 0.239 ± 0.003 mmHg O2 (-1). We used these oxygen-sensing films to measure the spatial and temporal changes in oxygen tension for paper-based cultures containing a breast cancer line that was engineered to constitutively express a fluorescent protein. By acquiring images of the oxygen-sensing film and the fluorescently labeled cells, we were able to approximate the oxygen consumption rates of the cells in our cultures.

  6. Helical CT imaging of clinically suspected appendicitis: Correlation of CT and histological findings

    International Nuclear Information System (INIS)

    Wong, S.K.; Chan, L.P.; Yeo, A.

    2002-01-01

    PURPOSE: The diagnosis of appendicitis is traditionally made on the basis of clinical findings supported by laboratory results. The aim of our study was to determine the accuracy and feasibility of using a relatively new technique of computed tomography (CT) using only colonic contrast medium. MATERIALS AND METHODS: A total of 50 patients clinically diagnosed as having appendicitis were prospectively examined before surgery with thin-collimation helical CT from the L3 level to the acetabular roof with only rectally administered colon contrast medium. The hard copy CT images were reviewed jointly by two radiologists and a consensus was reached for each patient. The results were then compared with the surgical and histological findings at appendicectomy. RESULTS: There were 35 true-positives, one false-positive, 12 true-negatives and two false-negatives for CT. This yielded an accuracy of 94%, sensitivity of 95%, specificity of 92%, positive predictive value of 97% and negative predictive value of 86%. The appendix was identified in 45 patients (90%) and obscured by an inflammatory mass in the remaining five. An alternative diagnosis was found in 10 of 12 normal CT examinations (83%). CONCLUSION: Helical CT with rectal contrast medium is a quick, well tolerated and accurate test to diagnose appendicitis. It can offer alternative, possibly non-surgical diagnosis in patients who would otherwise have undergone laparotomy. Wong, S.K. et al. (2002)

  7. The value of spiral CT scan on fracture of ankle joint and tarsal bones

    International Nuclear Information System (INIS)

    Li Zhaoli; Liang Jingyin; Pan Zhifeng

    2009-01-01

    Objective: To study the value of spiral CT scan on the fracture of ankle joint and tarsal bones. Methods: 43 cases with the fracture of ankle joint and tarsal bones were collected and analyzed. All the cases were examined by plain film radiography and spiral CT thin slice scan. Multi-planar reformation (MPR), surface shaded display (SSD) and other techniques of image post-processing were performed in 35 cases of them. Results: Spiral CT scan could demonstrate more fractures than plain film radiography in 28 cases(65.1%). There are 15 cases (34.9%) which are normal in plain film radiography but abnormal in Spiral CT scan. Spiral CT could demonstrate the different length, width, direction and number of linear low density shadow. SSD and MPR were performed again in the cases with avulsion fracture and fragmental fracture to demonstrate the fracture direction and the shape, size and location of fragments more clearly. Conclusion: Spiral CT thin slice scan with image post-processing techniques can play an important role in fracture of ankle joint and tarsal bones. (authors)

  8. Design recommendations for the optimized continuity diaphragm for prestressed concrete bulb-T beams.

    Science.gov (United States)

    2008-01-01

    This research focused on prestressed concrete bulb-T (PCBT) beams made composite with a cast-in-place concrete deck and continuous over several spans through the use of continuity diaphragms. The current design procedure in AASHTO states that a conti...

  9. Evaluation of pleural disease using MR and CT: With special reference to malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Knuuttila, A.; Kivisaari, L.; Kivisaari, A.; Palomaeki, M.; Tervahartiala, P.; Mattson, K.

    2001-01-01

    Purpose: To evaluate MR imaging and CT in differentiating malignant pleural mesothelioma from other malignancies or benign pleural disease. Material and Methods: Thirty-four patients (18 pleural mesothelioma, 9 other malignancies, 7 benign pleural diseases) were examined using enhanced CT and MR. Two radiologists reviewed the CT and two others the MR images. Comparisons were made between the diagnostic groups and the imaging methods. Results: The abnormalities commonly found in malignant disease, but significantly less frequently in benign pleural disease, were focal thickening and enhancement of inter lobar fissures. In mesothelioma, enhancement of inter lobar fissures, tumour invasion of the diaphragm, mediastinal soft tissue or chest wall, were significantly more often observed than in other malignancies and MR was the most sensitive method. In other malignancies, invasion of bony structures was a more common finding and was also better shown by MR. The contrast-enhanced T1 fat-suppressed (CET1fs) sequence detected these features better than other MR sequences. Conclusion: MR, especially the CET1fs sequence in three planes, gave more information than enhanced CT. Focal thickening and enhancement of inter lobar fissures were early abnormalities indicating malignant pleural disease. MR could be clinically useful for differentiating mesothelioma from other pleural diseases

  10. Evaluation of pleural disease using MR and CT: With special reference to malignant pleural mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Knuuttila, A. [Helsinki Univ. Central Hospital (Finland). Dept. of Medicine; Kivisaari, L.; Kivisaari, A.; Palomaeki, M.; Tervahartiala, P. [Helsinki Univ. Central Hospital (Finland). Dept. of Radiology; Mattson, K. [Helsinki Univ. Central Hospital (Finland). Dept. of Medicine

    2001-09-01

    Purpose: To evaluate MR imaging and CT in differentiating malignant pleural mesothelioma from other malignancies or benign pleural disease. Material and Methods: Thirty-four patients (18 pleural mesothelioma, 9 other malignancies, 7 benign pleural diseases) were examined using enhanced CT and MR. Two radiologists reviewed the CT and two others the MR images. Comparisons were made between the diagnostic groups and the imaging methods. Results: The abnormalities commonly found in malignant disease, but significantly less frequently in benign pleural disease, were focal thickening and enhancement of inter lobar fissures. In mesothelioma, enhancement of inter lobar fissures, tumour invasion of the diaphragm, mediastinal soft tissue or chest wall, were significantly more often observed than in other malignancies and MR was the most sensitive method. In other malignancies, invasion of bony structures was a more common finding and was also better shown by MR. The contrast-enhanced T1 fat-suppressed (CET1fs) sequence detected these features better than other MR sequences. Conclusion: MR, especially the CET1fs sequence in three planes, gave more information than enhanced CT. Focal thickening and enhancement of inter lobar fissures were early abnormalities indicating malignant pleural disease. MR could be clinically useful for differentiating mesothelioma from other pleural diseases.

  11. Estimation of diaphragm length in patients with severe chronic obstructive pulmonary disease.

    Science.gov (United States)

    McKenzie, D K; Gorman, R B; Tolman, J; Pride, N B; Gandevia, S C

    2000-11-01

    In patients with advanced chronic obstructive pulmonary disease (COPD) diaphragm function may be compromised because of reduced muscle fibre length. Diaphragm length (L(Di)) can be estimated from measurements of transverse diameter of the rib cage (D(Rc)) and the length of the zone of apposition (L(Zapp)) in healthy subjects, but this method has not been validated in patients with COPD. Postero-anterior chest radiographs were obtained at total lung capacity (TLC), functional residual capacity (FRC) and residual volume (RV) in nine male patients with severe COPD (mean [S.D.]; FEV(1), 23 [6] %pred.; FRC, 199 [15] %pred.). Radiographs taken at TLC were used to identify the lateral costal insertions of the diaphragm (L(Zapp) assumed to approach zero at TLC). L(Di) was measured directly and also estimated from measurements of L(Zapp) and D(Rc) using a prediction equation derived from healthy subjects. The estimation of L(Di) was highly accurate with an intraclass correlation coefficient of 0.93 and 95% CI of approximately +/-8% of the true value. L(Di) decreased from 426 (64) mm at RV to 305 (31) mm at TLC. As there were only small and variable changes in D(Rc) across the lung volume range, most of the L(Di) changes occurred in the zone of apposition. Additional studies showed that measurements of L(Di) from PA and lateral radiographs performed at different lung volumes were tightly correlated. These results suggest that non-invasive measurements of L(Zapp) in the coronal plane (e.g. using ultrasonography) and D(Rc) (e.g. using magnetometers) can be used to provide an accurate estimate of L(Di) in COPD patients.

  12. Effects of Processing Parameters on the Forming Quality of C-Shaped Thermosetting Composite Laminates in Hot Diaphragm Forming Process

    Science.gov (United States)

    Bian, X. X.; Gu, Y. Z.; Sun, J.; Li, M.; Liu, W. P.; Zhang, Z. G.

    2013-10-01

    In this study, the effects of processing temperature and vacuum applying rate on the forming quality of C-shaped carbon fiber reinforced epoxy resin matrix composite laminates during hot diaphragm forming process were investigated. C-shaped prepreg preforms were produced using a home-made hot diaphragm forming equipment. The thickness variations of the preforms and the manufacturing defects after diaphragm forming process, including fiber wrinkling and voids, were evaluated to understand the forming mechanism. Furthermore, both interlaminar slipping friction and compaction behavior of the prepreg stacks were experimentally analyzed for showing the importance of the processing parameters. In addition, autoclave processing was used to cure the C-shaped preforms to investigate the changes of the defects before and after cure process. The results show that the C-shaped prepreg preforms with good forming quality can be achieved through increasing processing temperature and reducing vacuum applying rate, which obviously promote prepreg interlaminar slipping process. The process temperature and forming rate in hot diaphragm forming process strongly influence prepreg interply frictional force, and the maximum interlaminar frictional force can be taken as a key parameter for processing parameter optimization. Autoclave process is effective in eliminating voids in the preforms and can alleviate fiber wrinkles to a certain extent.

  13. Effect of cluster thinning and prohexadione calcium applications on phenolic composition and sensory properties of red wines.

    Science.gov (United States)

    Avizcuri-Inac, José-Miguel; Gonzalo-Diago, Ana; Sanz-Asensio, Jesús; Martínez-Soria, María-Teresa; López-Alonso, Miguel; Dizy-Soto, Marta; Echávarri-Granado, José-Federico; Vaquero-Fernández, Luis; Fernández-Zurbano, Purificación

    2013-02-06

    The overall objective of this study was to investigate the effect of manual cluster thinning (CT) and the application of the growth regulator Prohexadione calcium (ProCa) on the phenolic composition and the sensory profile of Tempranillo and Grenache wines produced from treated vines in La Rioja (Spain). ProCa was applied at preblooming and CT was carried out at veraison in two consecutive years. Different physicochemical parameters and analyses of phenolic compounds were carried out in control, CT and ProCa grapes and wines and wine sensory was performed. Thinning treatments decreased crop yield, besides ProCa application reduced berry size, and berry weight. Color and phenolic composition of Grenache and Tempranillo wines in general were affected by thinning treatments, with an increase in anthocyanin, flavanol and flavonol concentrations. In sensory analysis, wines obtained from thinned vines presented higher values for several aromatic (e.g., white and yellow fruits, fresh flowers) and taste attributes (i.e., astringency, bitternes, persistence). CT and ProCa treatments resulted in an improvement in wine quality. In general, similar results in phenolic composition, sensory properties and quality of wines were obtained by manual and chemical cluster thinning. ProCa as a growth regulator may be an option for a quality vitiviniculture.

  14. Comparative morphology of the diaphragm of white tufted-ear marmoset and the white-fronted marmoset

    Directory of Open Access Journals (Sweden)

    Thais Borges Lessa

    2012-03-01

    Full Text Available The marmosets of the Callithrix genus have a great importance in the research field, not only for its occurrence in the ecosystems of South America and Central America, but also because of its small size and easy management. This study aimed to characterize the ultrastructure of the diaphragm of four adult animals of the C. jacchus species and four animals of the C. geoffroyi species that died from natural causes. Diaphragms were collected, dissected, and fixed in 10% formaldehyde and analyzed through scanning electron microscopy. It was observed the presence of an external membrane of connective tissue, with cylindrical muscle fibers arranged in rows perpendicular to the longitudinal axis and grouped into fascicles. In C. jacchus it was observed a discontinuous and linear fibers’ architecture, resulting in a score of 7 and 8 fascicles for male and female, respectively. In C. geoffroyi the fiber had a continuous shape, but also linear, yielding a total of 9 and 6 fascicles for male and female, respectively. The architecture of muscle fibers and the count of fascicles of the coastal face of the diaphragm suggest differences between the species C. geoffroyi and C. jacchus and between males and females, intra- and interspecies.

  15. X-ray and CT findings of costal eosinophilic granuloma

    International Nuclear Information System (INIS)

    Tu Zhanhai; Lin Zhengyu; Chen Yiguang

    2010-01-01

    Objective: To study the X-ray and CT features of costal eosinophilic granuloma for a better understanding. Methods: Eight patients with costal eosinophilic granuloma proved by surgery or biopsy were analyzed retrospectively. All patients had X-ray plain film, 6 patients had CT examination, including a case of enhanced CT scan. Results: All 8 lesions were solitary. Six lesions were in the anterior rib and 2 in the posterior rib. On X-ray, all case showed single cavity and oval lesion with clear boundary. On CT images, 5 lesions demonstrated expansile destruction of bone with cortical bone thinning, and 3 were osteolystic destruction with soft tissue mass around. On the patient with enhanced CT scan, the lesions showed a moderate and uniform enhancement. Conclusion: The X-ray and CT findings of costal eosinophilic granuloma are characteristic. (authors)

  16. Prevalence and histopathological finding of thin-walled and thick-walled Sarcocysts in slaughtered cattle of Karaj abattoir, Iran.

    Science.gov (United States)

    Nourollahi-Fard, Saeid R; Kheirandish, Reza; Sattari, Saeid

    2015-06-01

    Sarcocystosis is a zoonotic disease caused by Sarcocystis spp. with obligatory two host life cycle generally alternating between an herbivorous intermediate host and a carnivorous definitive host. Some species of this coccidian parasite can cause considerable morbidity and mortality in cattle. The present study was set to investigate the prevalence of Sarcocystis spp. and type of cyst wall in slaughtered cattle of Karaj abattoir, Iran. For this purpose 125 cattle (88 males and 37 females) were investigated for the presence of macroscopic and microscopic Sarcocystis cysts in muscular tissues. No macroscopic Sarcocystis cysts were found in any of the samples. In light microscopy, 121 out of 125 cattle (96.8 %) had thin-walled cysts of Sarcocystis cruzi, while 43 out of them (34.4 %) had thick-walled Sarcocystis cyst. In this survey, the most infected tissue was esophagus and heart and the less was diaphragm. Thin-walled cysts (S. cruzi) mostly found in heart and skeletal muscle showed the less. However, thick-walled cyst (S. hominis or S. hirsuta) mostly were detected in diaphragm, heart muscle showed no thick-walled cyst. No significant relation was observed between age and sex and the rate of infection. The results showed that Sarcocystis cyst is prevalent in cattle in the North part of Iran and the evaluation of infection potential can be useful when considering control programs.

  17. Acute gastric volvulus secondary to eventration of the diaphragm in a child

    Directory of Open Access Journals (Sweden)

    Singal A

    2006-01-01

    Full Text Available We report an 18-month-old boy who presented with acute organoaxial volvulus of stomach secondary to eventration of diaphragm. Clinically, the child exhibited classical triad of epigastric distension, unproductive retching and inability to pass a nasogastric tube. Successful operative management is presented and relevant literature is discussed.

  18. Electrical activity of the diaphragm during nCPAP and high flow nasal cannula

    NARCIS (Netherlands)

    de Waal, C. G.; Hutten, G. J.; Kraaijenga, J. V.; de Jongh, F. H.; van Kaam, A. H.

    2017-01-01

    Objective To determine if the electrical activity of the diaphragm, as measure of neural respiratory drive and breathing effort, changes over time in preterm infants transitioned from nasal continuous positive airway pressure (nCPAP) to high flow nasal cannula (HFNC). Design Prospective

  19. Evaluation of COPD's diaphragm motion extracted from 4D-MRI

    Science.gov (United States)

    Swastika, Windra; Masuda, Yoshitada; Kawata, Naoko; Matsumoto, Koji; Suzuki, Toshio; Iesato, Ken; Tada, Yuji; Sugiura, Toshihiko; Tanabe, Nobuhiro; Tatsumi, Koichiro; Ohnishi, Takashi; Haneishi, Hideaki

    2015-03-01

    We have developed a method called intersection profile method to construct a 4D-MRI (3D+time) from time-series of 2D-MRI. The basic idea is to find the best matching of the intersection profile from the time series of 2D-MRI in sagittal plane (navigator slice) and time series of 2D-MRI in coronal plane (data slice). In this study, we use 4D-MRI to semiautomatically extract the right diaphragm motion of 16 subjects (8 healthy subjects and 8 COPD patients). The diaphragm motion is then evaluated quantitatively by calculating the displacement of each subjects and normalized it. We also generate phase-length map to view and locate paradoxical motion of the COPD patients. The quantitative results of the normalized displacement shows that COPD patients tend to have smaller displacement compared to healthy subjects. The average normalized displacement of total 8 COPD patients is 9.4mm and the average of normalized displacement of 8 healthy volunteers is 15.3mm. The generated phase-length maps show that not all of the COPD patients have paradoxical motion, however if it has paradoxical motion, the phase-length map is able to locate where does it occur.

  20. Structure of diaphragm floor of reactor container, construction module and construction method thereof

    International Nuclear Information System (INIS)

    Hasegawa, Hiroshi; Oikawa, Tadaaki; Ushiroda, Koichi; Matsuura, Tadashi; Komaru, Toshimi; Nemoto, Yoichi; Makita, Tatsuo; Maezawa, Sumito.

    1998-01-01

    A diaphragm floor of a reactor container has a structure comprising iron beams buried in concretes and connection members connecting the iron beams and liners, in which the liners are supported by the iron beams, and the load of the iron reinforced concretes when formed on the liner is supported by the iron beams thereby enabling to construct a diaphragm floor with no or reduced amount of temporary support members. As a result, the construction operation can be promoted by reducing the amount of the temporary support members or making the removing operation of the temporary support members unnecessary. The concrete layer comprises at least two upper and lower layers of a firstly formed concrete layer and a subsequently formed concrete layer, and the iron beams have such a strength capable of enduring the load applied when the firstly formed concrete is placed. (N.H.)

  1. Developing a new ultrasonic method to assess diaphragm movement and comparing the accuracy with existing methods

    DEFF Research Database (Denmark)

    Helbo Skaarup, Søren; Løkke, Anders; Laursen, Christian

    2017-01-01

    Introduction: Diaphragm is the most important respiratory muscle. Movement can be evaluated with ultrasound. Currently two different methods are used, M-mode and B-mode. However, diaphragm movement is complex.Aim: We hypothesized that the two existing methods are imprecise as they only measure...... film clips independently to assess inter-rater variability.Results: We found a linear correlation between FVC and diaphragmatic movement. M-mode had Pearson r=0.84 (95%CI 0.76-0.89), B-mode had r=0.68 (95%CI 0.55-0.79) and Area-measurement had r=0.84 (95%CI 0.77-0.90). Inter-rater agreement was r=0...

  2. Malignant Mesothelioma Versus Metastatic Carcinoma of the Pleura: A CT Challenge

    International Nuclear Information System (INIS)

    Bakhshayesh Karam, Mehrdad; Karimi, Shirin; Mosadegh, Leila; Chaibakhsh, Samira

    2016-01-01

    Malignant pleural mesothelioma (MPM) is a rare malignant neoplasm of the pleura that typically affects individuals occupationally exposed to asbestos through a variety of industries. MPM presents with several CT features similar to more common pleural diseases such as metastatic pleural malignancy. The aim of this study is to differentiate malignant pleural mesothelioma from metastatic carcinoma of the pleura by pathological and radiological assessment in order to investigate accuracy of CT scan in this regard and to compare CT features of these two malignancies. Chest CT scans of 55 pleural malignancy patients including MPM and metastatic pleural malignancy were evaluated in this retrospective study. The pathologist made the definite diagnosis based on immunohistochemistry. A chest radiologist unaware of the pathology diagnosis observed all CT scans. Several parameters including pleural thickening, pleural effusion, thickening of inter lobar fissure, contralateral extension, contraction of involved hemithorax, parenchymal involvement (infiltration, nodules, fibrosis), pleural mediastinal involvement, lymphadenopathy, extrapleural invasion (hepatic, chest wall, diaphragm, intraperitoneal), and pericardial involvement were checked. Data analysis was carried out using SPSS version 16, and the ability of CT scan to differentiate malignant pleural mesothelioma and metastatic pleural diseases was investigated. Totally 29 males and 26 females were assessed in this study. Based on pathology, 17 MPM and 38 metastatic pleural malignancies were diagnosed. According to CT study, about 82% of the patients with MPM and about 79% of the patients with metastatic pleural diseases were correctly diagnosed by a radiologist. The most common findings suggestive of MPM were pleural thickening (88.2%), loculated effusion (58.8%), and thickening of the interlobar fissure (47.1%). Whereas free pleural effusion (71.7%), parenchymal infiltration (65.8%) and pleural thickening (63.2%) were

  3. Differentiation of bacterial and non-bacterial community-acquired pneumonia by thin-section computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Isao [Department of Respiratory Medicine, Kurashiki Central Hospital, 1-1-1 Miwa, Kurashiki 710-8602 (Japan); Department of Respiratory Medicine, Kyoto University, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: isaoito@kuhp.kyoto-u.ac.jp; Ishida, Tadashi [Department of Respiratory Medicine, Kurashiki Central Hospital, 1-1-1 Miwa, Kurashiki 710-8602 (Japan)], E-mail: ishidat@kchnet.or.jp; Togashi, Kaori [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: ktogashi@kuhp.kyoto-u.ac.jp; Niimi, Akio [Department of Respiratory Medicine, Kyoto University, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: niimi@kuhp.kyoto-u.ac.jp; Koyama, Hiroshi [General Internal Medicine, National Hospital Organization Kyoto Medical Center, 1-1 Fukakusa-Mukohatacho, Fushimi-ku, Kyoto 612-8555 (Japan)], E-mail: hkoyama-kyt@umin.ac.jp; Ishimori, Takayoshi [Department of Radiology, Kurashiki Central Hospital, 1-1-1 Miwa, Kurashiki 710-8602 (Japan)], E-mail: ti10794@kchnet.or.jp; Kobayashi, Hisataka [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Molecular Imaging Program, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Building 10, Room 1B40, MSC1088, 10 Center Drive, Bethesda, MD 20892-1088 (United States)], E-mail: kobayash@mail.nih.gov; Mishima, Michiaki [Department of Respiratory Medicine, Kyoto University, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: mishima@kuhp.kyoto-u.ac.jp

    2009-12-15

    Background and objective: The management of community-acquired pneumonia (CAP) depends, in part, on the identification of the causative agents. The objective of this study was to determine the potential of thin-section computed tomography (CT) in differentiating bacterial and non-bacterial pneumonia. Patients and methods: Thin-section CT studies were prospectively examined in hospitalized CAP patients within 2 days of admission, followed by retrospective assessment by two pulmonary radiologists. Thin-section CT findings on the pneumonias caused by each pathogen were examined, and two types of pneumonias were compared. Using multivariate logistic regression analyses, receiver operating characteristic (ROC) curves were produced. Results: Among 183 CAP episodes (181 patients, 125 men and 56 women, mean age {+-} S.D.: 61.1 {+-} 19.7) examined by thin-section CT, the etiologies of 125 were confirmed (94 bacterial pneumonia and 31 non-bacterial pneumonia). Centrilobular nodules were specific for non-bacterial pneumonia and airspace nodules were specific for bacterial pneumonia (specificities of 89% and 94%, respectively) when located in the outer lung areas. When centrilobular nodules were the principal finding, they were specific but lacked sensitivity for non-bacterial pneumonia (specificity 98% and sensitivity 23%). To distinguish the two types of pneumonias, centrilobular nodules, airspace nodules and lobular shadows were found to be important by multivariate analyses. ROC curve analysis discriminated bacterial pneumonia from non-bacterial pneumonia among patients without underlying lung diseases, yielding an optimal point with sensitivity and specificity of 86% and 79%, respectively, but was less effective when all patients were analyzed together (70% and 84%, respectively). Conclusion: Thin-section CT examination was applied for the differentiation of bacterial and non-bacterial pneumonias. Though showing some potential, this examination at the present time would

  4. Differentiation of bacterial and non-bacterial community-acquired pneumonia by thin-section computed tomography

    International Nuclear Information System (INIS)

    Ito, Isao; Ishida, Tadashi; Togashi, Kaori; Niimi, Akio; Koyama, Hiroshi; Ishimori, Takayoshi; Kobayashi, Hisataka; Mishima, Michiaki

    2009-01-01

    Background and objective: The management of community-acquired pneumonia (CAP) depends, in part, on the identification of the causative agents. The objective of this study was to determine the potential of thin-section computed tomography (CT) in differentiating bacterial and non-bacterial pneumonia. Patients and methods: Thin-section CT studies were prospectively examined in hospitalized CAP patients within 2 days of admission, followed by retrospective assessment by two pulmonary radiologists. Thin-section CT findings on the pneumonias caused by each pathogen were examined, and two types of pneumonias were compared. Using multivariate logistic regression analyses, receiver operating characteristic (ROC) curves were produced. Results: Among 183 CAP episodes (181 patients, 125 men and 56 women, mean age ± S.D.: 61.1 ± 19.7) examined by thin-section CT, the etiologies of 125 were confirmed (94 bacterial pneumonia and 31 non-bacterial pneumonia). Centrilobular nodules were specific for non-bacterial pneumonia and airspace nodules were specific for bacterial pneumonia (specificities of 89% and 94%, respectively) when located in the outer lung areas. When centrilobular nodules were the principal finding, they were specific but lacked sensitivity for non-bacterial pneumonia (specificity 98% and sensitivity 23%). To distinguish the two types of pneumonias, centrilobular nodules, airspace nodules and lobular shadows were found to be important by multivariate analyses. ROC curve analysis discriminated bacterial pneumonia from non-bacterial pneumonia among patients without underlying lung diseases, yielding an optimal point with sensitivity and specificity of 86% and 79%, respectively, but was less effective when all patients were analyzed together (70% and 84%, respectively). Conclusion: Thin-section CT examination was applied for the differentiation of bacterial and non-bacterial pneumonias. Though showing some potential, this examination at the present time would not

  5. Normal appearance and size of the diaphragmatic crura in children: CT evaluation

    International Nuclear Information System (INIS)

    Brengle, M.; Cohen, M.D.; Katz, B.

    1996-01-01

    Purpose. The objectives of the study were to document the normal CT appearance and size of the crura of the diaphragm in children. Materials and methods. The CT scans of 80 children (0-15 years) were reviewed. The children were divided into eight age groups. The maximal transverse diameters of the right and left crura were measured. They were normalized by comparison with the transverse and anterior-posterior diameters of the 12th thoracic vertebra (T12) and the transverse abdominal diameter at T12. The crura were also evaluated as to whether their contour was smooth or nodular. Results. The diaphragmatic crura of smaller children appear large, relative to body size and the diameters of the T12 vertebral body, compared with those in older children. Crural width does not increase significantly with age. Additionally, the crura were found to have a greater tendency to be nodular in appearance in children under the age of 5 years than in older children. Conclusion. Diaphragmatic crura are more nodular and larger relative to body size in younger children. (orig.). With 6 figs., 2 tabs

  6. Quantification of the variability of diaphragm motion and implications for treatment margin construction

    NARCIS (Netherlands)

    Rit, Simon; van Herk, Marcel; Zijp, Lambert; Sonke, Jan-Jakob

    2012-01-01

    To quantify the variability of diaphragm motion during free-breathing radiotherapy of lung patients and its effect on treatment margins to account for geometric uncertainties. Thirty-three lung cancer patients were analyzed. Each patient had 5-19 cone-beam scans acquired during different treatment

  7. Lung Dose Calculation With SPECT/CT for 90Yittrium Radioembolization of Liver Cancer

    International Nuclear Information System (INIS)

    Yu, Naichang; Srinivas, Shaym M.; DiFilippo, Frank P.; Shrikanthan, Sankaran; Levitin, Abraham; McLennan, Gordon; Spain, James; Xia, Ping; Wilkinson, Allan

    2013-01-01

    Purpose: To propose a new method to estimate lung mean dose (LMD) using technetium-99m labeled macroaggregated albumin ( 99m Tc-MAA) single photon emission CT (SPECT)/CT for 90 Yttrium radioembolization of liver tumors and to compare the LMD estimated using SPECT/CT with clinical estimates of LMD using planar gamma scintigraphy (PS). Methods and Materials: Images of 71 patients who had SPECT/CT and PS images of 99m Tc-MAA acquired before TheraSphere radioembolization of liver cancer were analyzed retrospectively. LMD was calculated from the PS-based lung shunt assuming a lung mass of 1 kg and 50 Gy per GBq of injected activity shunted to the lung. For the SPECT/CT-based estimate, the LMD was calculated with the activity concentration and lung volume derived from SPECT/CT. The effect of attenuation correction and the patient's breathing on the calculated LMD was studied with the SPECT/CT. With these effects correctly taken into account in a more rigorous fashion, we compared the LMD calculated with SPECT/CT with the LMD calculated with PS. Results: The mean dose to the central region of the lung leads to a more accurate estimate of LMD. Inclusion of the lung region around the diaphragm in the calculation leads to an overestimate of LMD due to the misregistration of the liver activity to the lung from the patient's breathing. LMD calculated based on PS is a poor predictor of the actual LMD. For the subpopulation with large lung shunt, the mean overestimation from the PS method for the lung shunt was 170%. Conclusions: A new method of calculating the LMD for TheraSphere and SIR-Spheres radioembolization of liver cancer based on 99m Tc-MAA SPECT/CT is presented. The new method provides a more accurate estimate of radiation risk to the lungs. For patients with a large lung shunt calculated from PS, a recalculation of LMD based on SPECT/CT is recommended

  8. Documentation of diaphragmal paralysis with digital subtraction techniques. Dokumentation von Zwerchfellparesen mit digitaler Subtraktionstechnik

    Energy Technology Data Exchange (ETDEWEB)

    Waggershauser, T. (Muenchen Univ. (Germany). Radiologische Klinik und Poliklinik Muenchen Univ. (Germany). Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenkranke); Buente, E. (Muenchen Univ. (Germany). Radiologische Klinik und Poliklinik Muenchen Univ. (Germany). Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenkranke); Kohz, P. (Muenchen Univ. (Germany). Radiologische Klinik und Poliklinik Muenchen Univ. (Germany). Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenkranke); Fink, U. (Muenchen Univ. (Germany). Radiologische Klinik und Poliklinik Muenchen Univ. (Germany). Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenkranke)

    1992-01-01

    The causative factors for a paresis of the diaphragm are primarily subsequent to operations on lesions of the phrenic nerve or on such mediastinal tumors as lyphomas which result in compression or infiltration of the nerves. (orig.)

  9. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  10. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  11. Reduction of Cr(VI) in aqueous solution with DC diaphragm glow discharge

    International Nuclear Information System (INIS)

    Wang, Xiaoyan; Jin, Xinglong; Zhou, Minghua; Chen, Zhenhai; Deng, Kai

    2013-01-01

    This paper investigated the reduction of Cr(VI) in aqueous solution with direct current diaphragm glow discharge (DGD). The glow discharge sustained around the hole on a quartz tube which divided the electrolyte cell into two parts. The reduction efficiencies of Cr(VI) under different applied voltages, initial conductivities, hole diameters, hole numbers, initial pH values and initial concentrations were systematically studied. The results showed that the reduction efficiency of Cr(VI) increased with the increase of applied voltage, initial conductivity, hole diameter and hole number. The different initial pH values showed less effects on the reduction of Cr(VI). The reduction efficiency decreased with the increasing initial concentration. In addition, the simultaneous reduction of Cr(VI) and decolorization of acid orange (AO) with DGD were also fulfilled. Furthermore, the energy efficiency for Cr(VI) reduction with DGD was calculated and compared with those in photocatalysis and other glow discharge reactor

  12. Examination of human diaphragms for trichinosis, Hiroshima and Nagasaki

    Energy Technology Data Exchange (ETDEWEB)

    Gould, S E; Ozaki, Hiroyuki; Kimura, Kazuo

    1961-11-30

    Trichinella spiralis has been found in three species of mammals born in Hokkaido so it possibly infects other species in Japan, including man. Although examination of human diaphragms in a small series of 149 autopsies in Hiroshima and 37 autopsies in Nagasaki (by digestion, compression, and microscopic sections) failed to reveal any instance of trichinous infection, it is felt that the existence or absence of human trichinosis inJapan can be determined only by examination covering a larger series of autopsies, and performed in various parts of the country. 6 references.

  13. Enhanced Transmissions Through Three-dimensional Cascade Sharp Waveguide Bends Using C-slit Diaphragms.

    Science.gov (United States)

    Yang, Rui; Hu, Bowei; Zhang, Aofang; Gao, Dongxing; Wang, Hui; Shi, Ayuan; Lei, Zhenya; Yang, Pei

    2017-03-21

    Transmission properties through sharp rectangular waveguide bends are investigated to determine the cut-off bending angles of the wave propagation. We show that a simple metallic diaphragm at the bending corner with properly devised sub-wavelength defect apertures of C-slits would be readily to turn on the transmissions with scarce reflections of the propagating modes, while preserving the integrity of the transmitting fields soon after the bends. In particularly, our design also demonstrates the capability of eliminating all the unwanted cavity resonant transmissions that exist in the three-dimensional cascade sharp waveguide bends, and solely let the desired signals travel along the whole passage of the waveguide. The present approach, using C-slit diaphragms to support the sharp bending behaviors of the guided waves with greatly enhanced transmissions, would be especially effective in constructing novel waveguides and pave the way for the development of more compact and miniaturized electromagnetic systems that exploit these waveguide bends.

  14. [Diaphragm pacing for the ventilatory support of the quadriplegic patients with respiratory paralysis].

    Science.gov (United States)

    Cheng, H; Wang, L S; Pan, H C; Shoung, H M; Lee, L S

    1992-02-01

    Electrical stimulation of the phrenic nerve to pace the diaphragm in patients with chronic ventilatory insufficiency has been an established therapeutic modality since William W.L. Glenn first described using radiofrequency signals in 1978 to stimulate the phrenic nerves. Before this event, patients who were ventilator-dependent and thus bedridden because of respiratory paralysis associated with quadriplegia usually anticipated little chance for physical or psychosocial rehabilitation. Two cases of C1-C2 subluxtion with cord injury and chronic ventilatory insufficiency were implanted at VGH-Taipei with diaphragm pacemaker in 1988. Postoperative phrenic nerve stimulation was given according to individual training schedule. One case with total phrenic paralysis received bilateral phrenic nerve stimulation and became weaned from the ventilator 6 months later. The other case with partially active ventilatory function received unilateral phrenic nerve stimulation to compensate the ventilation. However, its final outcome still showed the necessity of a bilateral mode to achieve adequate ventilation irrespective of strenuous training for 2 years.

  15. Laser-induced vibration of a thin soap film.

    Science.gov (United States)

    Emile, Olivier; Emile, Janine

    2014-09-21

    We report on the vibration of a thin soap film based on the optical radiation pressure force. The modulated low power laser induces a counter gravity flow in a vertical free-standing draining film. The thickness of the soap film is then higher in the upper region than in the lower region of the film. Moreover, the lifetime of the film is dramatically increased by a factor of 2. Since the laser beam only acts mechanically on the film interfaces, such a film can be employed in an optofluidic diaphragm pump, the interfaces behaving like a vibrating membrane and the liquid in-between being the fluid to be pumped. Such a pump could then be used in delicate micro-equipment, in chips where temperature variations are detrimental and even in biological systems.

  16. PO2 Cycling Reduces Diaphragm Fatigue by Attenuating ROS Formation

    OpenAIRE

    Zuo, Li; Diaz, Philip T.; Chien, Michael T.; Roberts, William J.; Kishek, Juliana; Best, Thomas M.; Wagner, Peter D.

    2014-01-01

    Prolonged muscle exposure to low PO2 conditions may cause oxidative stress resulting in severe muscular injuries. We hypothesize that PO2 cycling preconditioning, which involves brief cycles of diaphragmatic muscle exposure to a low oxygen level (40 Torr) followed by a high oxygen level (550 Torr), can reduce intracellular reactive oxygen species (ROS) as well as attenuate muscle fatigue in mouse diaphragm under low PO2. Accordingly, dihydrofluorescein (a fluorescent probe) was used to monito...

  17. Using carboxylated nanocrystalline cellulose as an additive in cellulosic paper and poly (vinyl alcohol) fiber paper.

    Science.gov (United States)

    Cha, Ruitao; Wang, Chengyu; Cheng, Shaoling; He, Zhibin; Jiang, Xingyu

    2014-09-22

    Specialty paper (e.g. cigarette paper and battery diaphragm paper) requires extremely high strength properties. The addition of strength agents plays an important role in increasing strength properties of paper. Nanocrystalline cellulose (NCC), or cellulose whiskers, has the potential to enhance the strength properties of paper via improving inter-fibers bonding. This paper was to determine the potential of using carboxylated nanocrystalline cellulose (CNCC) to improve the strength properties of paper made of cellulosic fiber or poly (vinyl alcohol) (PVA) fiber. The results indicated that the addition of CNCC can effectively improve the strength properties. At a CNCC dosage of 0.7%, the tear index and tensile index of the cellulosic paper reached the maximum of 12.8 mN m2/g and 100.7 Nm/g, respectively. More importantly, when increasing the CNCC dosage from 0.1 to 1.0%, the tear index and tensile index of PVA fiber paper were increased by 67.29%, 22.55%, respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Investigation of piezoresistive effect in p-channel metal–oxide–semiconductor field-effect transistors fabricated on circular silicon-on-insulator diaphragms using cost-effective minimal-fab process

    Science.gov (United States)

    Liu, Yongxun; Tanaka, Hiroyuki; Umeyama, Norio; Koga, Kazuhiro; Khumpuang, Sommawan; Nagao, Masayoshi; Matsukawa, Takashi; Hara, Shiro

    2018-06-01

    P-channel metal–oxide–semiconductor field-effect transistors (PMOSFETs) with the 〈110〉 or 〈100〉 channel direction have been successfully fabricated on circular silicon-on-insulator (SOI) diaphragms using a cost-effective minimal-fab process, and their electrical characteristics have been systematically investigated before and after the SOI diaphragm formation. It was found that almost the same subthreshold slope (S-slope) and threshold voltage (V t) are observed in the fabricated PMOSFETs before and after the SOI diaphragm formation, and they are independent of the channel direction. On the other hand, significant variations in drain current were observed in the fabricated PMOSFETs with the 〈110〉 channel direction after the SOI diaphragm formation owing to the residual mechanical stress-induced piezoresistive effect. It was also confirmed that electrical characteristics of the fabricated PMOSFETs with the 〈100〉 channel direction are almost the same before and after the SOI diaphragm formation, i.e., not sensitive to the mechanical stress. Moreover, the drain current variations at different directions of mechanical stress and current flow were systematically investigated and discussed.

  19. Exercise Prevents Diaphragm Wasting Induced by Cigarette Smoke through Modulation of Antioxidant Genes and Metalloproteinases

    Directory of Open Access Journals (Sweden)

    Gracielle Vieira Ramos

    2018-01-01

    Full Text Available Background. The present study aimed to analyze the effects of physical training on an antioxidant canonical pathway and metalloproteinases activity in diaphragm muscle in a model of cigarette smoke-induced chronic obstructive pulmonary disease (COPD. Methods. Male mice were randomized into control, smoke, exercise, and exercise + smoke groups, which were maintained in trial period of 24 weeks. Gene expression of kelch-like ECH-associated protein 1; nuclear factor erythroid-2 like 2; and heme-oxygenase1 by polymerase chain reaction was performed. Metalloproteinases 2 and 9 activities were analyzed by zymography. Exercise capacity was evaluated by treadmill exercise test before and after the protocol. Results. Aerobic training inhibited diaphragm muscle wasting induced by cigarette smoke exposure. This inhibition was associated with improved aerobic capacity in those animals that were submitted to 24 weeks of aerobic training, when compared to the control and smoke groups, which were not submitted to training. The aerobic training also downregulated the increase of matrix metalloproteinases (MMP-2 and MMP-9 and upregulated antioxidant genes, such as nuclear factor erythroid-2 like 2 (NRF2 and heme-oxygenase1 (HMOX1, in exercise + smoke group compared to smoke group. Conclusions. Treadmill aerobic training protects diaphragm muscle wasting induced by cigarette smoke exposure involving upregulation of antioxidant genes and downregulation of matrix metalloproteinases.

  20. Right diaphragmatic rupture and hepatic hernia: an indirect sign on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi, N.; Nicaise, N.; Struyven, J.; Gansbeke, D. van [Department of Radiology, Hopital Erasme, Brussel (Belgium); DeBacker, D. [Intensive Care Unit, Hopital Erasme, Brussels (Belgium)

    1999-06-01

    We report a case of blunt traumatic right diaphragm rupture with hepatic hernia. The diagnosis was first suggested by an abnormal hepatic location depicted on axial CT. This finding can be considered as a potentially new indirect sign of right diaphragm rupture in patients with blunt trauma. The diagnosis was then confirmed by reformatted CT and MR images. (orig.) With 1 fig., 16 refs.

  1. Where Did the Water Go?: Boyle's Law and Pressurized Diaphragm Water Tanks

    Science.gov (United States)

    Brimhall, James; Naga, Sundar

    2007-01-01

    Many homes use pressurized diaphragm tanks for storage of water pumped from an underground well. These tanks are very carefully constructed to have separate internal chambers for the storage of water and for the air that provides the pressure. One might expect that the amount of water available for use from, for example, a 50-gallon tank would be…

  2. Comparison of 133Xe gas dynamic SPECT and thin-section CT in patients with pulmonary emphysema

    International Nuclear Information System (INIS)

    Takahashi, Kazue; Satoh, Katashi; Ohkawa, Motoomi

    2001-01-01

    We assessed 133 Xe gas dynamic single photon emission computed tomography (SPECT) by comparing washout axial images with thin-section CT (TSCT) in patients with pulmonary emphysema. Twenty-three patients were studied. All patients were diagnosed as having pulmonary emphysema on the basis of TSCT. We compared TSCT of upper, middle and lower lung fields with 133 Xe gas dynamic SPECT axial images at the corresponding levels during the 3 to 4 minutes of washout phase. If the degree of 133 Xe gas retention or TSCT finding of ventral and dorsal parts was not the same, the images were divided into two parts. A total of 174 lesions in 23 cases were examined, but 3 lesions having no retention of 133 Xe gas at equilibrium phase were excluded. The results showed that: there were 37 lesions (21.6%) with equivalent severity on both images; there were 42 lesions (24.5%) with more severity on 133 Xe gas dynamic SPECT than on TSCT; and there were 92 lesions (53.8%) with more severity on TSCT than on 133 Xe gas dynamic SPECT. The severity on 133 Xe gas dynamic SPECT and TSCT was not always compatible. One of the reasons for the variable 133 Xe gas retention even when the lesion had the same severity on TSCT, may be bronchial stricture which cannot be seen on TSCT. By comparison of axial images of 133 Xe gas dynamic SPECT with CT images, we could recognize the areas of 133 Xe gas retention in detail. Results suggest that 133 Xe gas dynamic SPECT can be useful to identify ventilation impairment in pulmonary emphysema. (author)

  3. Lung Dose Calculation With SPECT/CT for {sup 90}Yittrium Radioembolization of Liver Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Naichang, E-mail: yun@ccf.org [Department of Radiation Oncology, Cleveland Clinic, Cleveland, OH (United States); Srinivas, Shaym M.; DiFilippo, Frank P.; Shrikanthan, Sankaran [Department of Nuclear Medicine, Cleveland Clinic, Cleveland, OH (United States); Levitin, Abraham; McLennan, Gordon; Spain, James [Department of Interventional Radiology, Cleveland Clinic, Cleveland, OH (United States); Xia, Ping; Wilkinson, Allan [Department of Radiation Oncology, Cleveland Clinic, Cleveland, OH (United States)

    2013-03-01

    Purpose: To propose a new method to estimate lung mean dose (LMD) using technetium-99m labeled macroaggregated albumin ({sup 99m}Tc-MAA) single photon emission CT (SPECT)/CT for {sup 90}Yttrium radioembolization of liver tumors and to compare the LMD estimated using SPECT/CT with clinical estimates of LMD using planar gamma scintigraphy (PS). Methods and Materials: Images of 71 patients who had SPECT/CT and PS images of {sup 99m}Tc-MAA acquired before TheraSphere radioembolization of liver cancer were analyzed retrospectively. LMD was calculated from the PS-based lung shunt assuming a lung mass of 1 kg and 50 Gy per GBq of injected activity shunted to the lung. For the SPECT/CT-based estimate, the LMD was calculated with the activity concentration and lung volume derived from SPECT/CT. The effect of attenuation correction and the patient's breathing on the calculated LMD was studied with the SPECT/CT. With these effects correctly taken into account in a more rigorous fashion, we compared the LMD calculated with SPECT/CT with the LMD calculated with PS. Results: The mean dose to the central region of the lung leads to a more accurate estimate of LMD. Inclusion of the lung region around the diaphragm in the calculation leads to an overestimate of LMD due to the misregistration of the liver activity to the lung from the patient's breathing. LMD calculated based on PS is a poor predictor of the actual LMD. For the subpopulation with large lung shunt, the mean overestimation from the PS method for the lung shunt was 170%. Conclusions: A new method of calculating the LMD for TheraSphere and SIR-Spheres radioembolization of liver cancer based on {sup 99m}Tc-MAA SPECT/CT is presented. The new method provides a more accurate estimate of radiation risk to the lungs. For patients with a large lung shunt calculated from PS, a recalculation of LMD based on SPECT/CT is recommended.

  4. Lung dose calculation with SPECT/CT for ⁹⁰Yittrium radioembolization of liver cancer.

    Science.gov (United States)

    Yu, Naichang; Srinivas, Shaym M; Difilippo, Frank P; Shrikanthan, Sankaran; Levitin, Abraham; McLennan, Gordon; Spain, James; Xia, Ping; Wilkinson, Allan

    2013-03-01

    To propose a new method to estimate lung mean dose (LMD) using technetium-99m labeled macroaggregated albumin ((99m)Tc-MAA) single photon emission CT (SPECT)/CT for (90)Yttrium radioembolization of liver tumors and to compare the LMD estimated using SPECT/CT with clinical estimates of LMD using planar gamma scintigraphy (PS). Images of 71 patients who had SPECT/CT and PS images of (99m)Tc-MAA acquired before TheraSphere radioembolization of liver cancer were analyzed retrospectively. LMD was calculated from the PS-based lung shunt assuming a lung mass of 1 kg and 50 Gy per GBq of injected activity shunted to the lung. For the SPECT/CT-based estimate, the LMD was calculated with the activity concentration and lung volume derived from SPECT/CT. The effect of attenuation correction and the patient's breathing on the calculated LMD was studied with the SPECT/CT. With these effects correctly taken into account in a more rigorous fashion, we compared the LMD calculated with SPECT/CT with the LMD calculated with PS. The mean dose to the central region of the lung leads to a more accurate estimate of LMD. Inclusion of the lung region around the diaphragm in the calculation leads to an overestimate of LMD due to the misregistration of the liver activity to the lung from the patient's breathing. LMD calculated based on PS is a poor predictor of the actual LMD. For the subpopulation with large lung shunt, the mean overestimation from the PS method for the lung shunt was 170%. A new method of calculating the LMD for TheraSphere and SIR-Spheres radioembolization of liver cancer based on (99m)Tc-MAA SPECT/CT is presented. The new method provides a more accurate estimate of radiation risk to the lungs. For patients with a large lung shunt calculated from PS, a recalculation of LMD based on SPECT/CT is recommended. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Prospective respiratory-gated micro-CT of free breathing rodents

    International Nuclear Information System (INIS)

    Ford, Nancy L.; Nikolov, Hristo N.; Norley, Chris J.D.; Thornton, Michael M.; Foster, Paula J.; Drangova, Maria; Holdsworth, David W.

    2005-01-01

    Microcomputed tomography (Micro-CT) has the potential to noninvasively image the structure of organs in rodent models with high spatial resolution and relatively short image acquisition times. However, motion artifacts associated with the normal respiratory motion of the animal may arise when imaging the abdomen or thorax. To reduce these artifacts and the accompanying loss of spatial resolution, we propose a prospective respiratory gating technique for use with anaesthetized, free-breathing rodents. A custom-made bed with an embedded pressure chamber was connected to a pressure transducer. Anaesthetized animals were placed in the prone position on the bed with their abdomens located over the chamber. During inspiration, the motion of the diaphragm caused an increase in the chamber pressure, which was converted into a voltage signal by the transducer. An output voltage was used to trigger image acquisition at any desired time point in the respiratory cycle. Digital radiographic images were acquired of anaesthetized, free-breathing rats with a digital radiographic system to correlate the respiratory wave form with respiration-induced organ motion. The respiratory wave form was monitored and recorded simultaneously with the x-ray radiation pulses, and an imaging window was defined, beginning at end expiration. Phantom experiments were performed to verify that the respiratory gating apparatus was triggering the micro-CT system. Attached to the distensible phantom were 100 μm diameter copper wires and the measured full width at half maximum was used to assess differences in image quality between respiratory-gated and ungated imaging protocols. This experiment allowed us to quantify the improvement in the spatial resolution, and the reduction of motion artifacts caused by moving structures, in the images resulting from respiratory-gated image acquisitions. The measured wire diameters were 0.135 mm for the stationary phantom image, 0.137 mm for the image gated at end

  6. CT findings of fundal hemorrhage in subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Munemoto, Shigeru; Ishiguro, Shuzo; Kimura, Akira; Futami, Kazuya; Kogure, Yuzaburo; Wakamatsu, Koichi; Demachi, Hiroshi

    1987-01-01

    The patient was a 66-year-old man. He lost consciousness as a result of a third subarachnoid hemorrhage attack. On neurological examination, he was found to be comatose and to have no spontaneous respiration. A mydriasis was noticed on both eyes. Bilateral retinal bleeding was also observed, with the bleeding of the left side more severe than that of the right side. After his death, his brain and eyes were examined by means of a CT scan. The CT films showed a severe subarachnoid hemorrhage and ventricular hematoma. The thin-sliced CT films showed left retinal bleeding. Retinal bleeding may be caused by a subarachnoid hemorrhage. Usually we make a sketch of the retinal bleeding on the basis of a doctor's report. A photo of an optic fundus is a good record; however, taking a photo is troublesome for severely ill patients. The CT finding of retinal bleeding is gross, but a CT image is one good way to record retinal bleeding. (author)

  7. Image quality of paper prints compared to film copies in CT investigations; Bildqualitaet von Papierausdrucken zur Befunddokumentation im Vergleich zu Laserfilmen bei MSCT-Untersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Bley, T.; Burger, D.; Ghanem, N.; Thuerl, C.; Saueressig, U.; Kotter, E.; Langer, M. [Abt. Roentgendiagnostik, Radiologische Klinik, Universitaetsklinikum Freiburg (Germany)

    2002-04-01

    Purpose: Evaluation of image quality of paper prints in routine CT investigations. Method: The image quality of paper prints from 104 CT scans of daily routine investigations was analysed by three observer three observers according to a five-point ranking scale for contrast, grey level, spatial resolution, and subjective confidence in correct evaluation. Each study was rated ''acceptable'' or ''not acceptable for documentation''. Results: In 312 ratings the mean grade for contrast was 2.7, for grey levels 3.2, and for spatial resolution 3.3. Grades ranged from 1 = very good to 5 = insufficient. Subjective confidence in correct evaluation was rated as ''certain'' in 77.4%, ''likely'' in 18.4% and ''impossible to evaluate'' in 4.2% of cases. 93.7% of printed CT images were rated ''acceptable for documentation''. Conclusion: Image quality of paper prints does not reach the quality of laser films concerning its contrast, grey levels, and spatial resolution. Nevertheless, paper prints are acceptable for documentation of findings in most CT investigations. A high confidence in correct evaluation was found. Limitations are found in documentation of small coin lesions of the lung and ischemic lesions of the neurocranium. (orig.) [German] Ziel: Qualitaetsbewertung von Papierausdrucken zur Bilddokumentation von Routine-CT-Untersuchungen. Material und Methoden: Bei 104 Routine-CT-Untersuchungen werteten drei Untersucher (insgesamt 312 Auswertungen) die Bildqualitaet von Papierausdrucken im Vergleich zu Laserfilmen bezueglich Kontrast, Grauwerten und Aufloesung sowie ''persoenlicher Befundsicherheit'' (Skala 1 - 5) aus. Abschliessend wurde entschieden, ob der Papierausdruck fuer die Befunddokumentation ausreiche. Ergebnisse: Mit Bewertungen zwischen 1 fuer ''sehr gut'' und 5 fuer &apos

  8. Primary thyroid lymphoma: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo-Cheol; Han, Moon Hee E-mail: hanmh@radcom.snu.ac.kr; Kim, Keon Ha; Jae, Hwan Jun; Lee, Sang Hyun; Kim, Sam Soo; Kim, Kwang Hyun; Chang, Kee-Hyun

    2003-06-01

    Introduction: To evaluate the computed tomographic (CT) findings of primary thyroid lymphoma. Methods and material: The clinicopathological data and CT images of nine patients with primary thyroid lymphoma were retrospectively reviewed. The CT appearances were classified into three types: type 1, a solitary nodule surrounded by normal thyroid tissue; type 2, multiple nodules in the thyroid, and type 3, a homogeneously enlarged both thyroid glands with a reduced attenuation with or without peripheral thin hyperattenuating thyroid tissue. Results: All patients had a rapidly enlarging thyroid mass and coexistent Hashimoto's thyroiditis. One patient showed type 1 pattern, three type 2, and five type 3. Six patients had homogeneous tumor isoattenuating to surrounding muscles. The tumors had a strong tendency to compress normal remnant thyroid and the surrounding structure without invasion. Conclusion: Primary thyroid lymphoma should be included in the differential diagnosis when old female had a homogeneous thyroidal mass isoattenuating to muscles, which does not invade surrounding structures.

  9. Cone beam CT with zonal filters for simultaneous dose reduction, improved target contrast and automated set-up in radiotherapy

    International Nuclear Information System (INIS)

    Moore, C J; Marchant, T E; Amer, A M

    2006-01-01

    Cone beam CT (CBCT) using a zonal filter is introduced. The aims are reduced concomitant imaging dose to the patient, simultaneous control of body scatter for improved image quality in the tumour target zone and preserved set-up detail for radiotherapy. Aluminium transmission diaphragms added to the CBCT x-ray tube of the Elekta Synergy TM linear accelerator produced an unattenuated beam for a central 'target zone' and a partially attenuated beam for an outer 'set-up zone'. Imaging doses and contrast noise ratios (CNR) were measured in a test phantom for transmission diaphragms 12 and 24 mm thick, for 5 and 10 cm long target zones. The effect on automatic registration of zonal CBCT to conventional CT was assessed relative to full-field and lead-collimated images of an anthropomorphic phantom. Doses along the axis of rotation were reduced by up to 50% in both target and set-up zones, and weighted dose (two thirds surface dose plus one third central dose) was reduced by 10-20% for a 10 cm long target zone. CNR increased by up to 15% in zonally filtered CBCT images compared to full-field images. Automatic image registration remained as robust as that with full-field images and was superior to CBCT coned down using lead-collimation. Zonal CBCT significantly reduces imaging dose and is expected to benefit radiotherapy through improved target contrast, required to assess target coverage, and wide-field edge detail, needed for robust automatic measurement of patient set-up error

  10. Degenerative osteoarthritis of atlanto-odontoid joint: CT findings and clinical analysis

    International Nuclear Information System (INIS)

    Xu Aide; Wang Song; Mao Yunhua

    1998-01-01

    Purpose: To analyze the CT appearances and clinical aspects of the degeneration at atlanto-odontoid(A-O) joint. Methods: Thin section axial CT scans, of AO joints were studied in 317 consecutive patients who underwent brain or cervical spine CT examinations. The images were viewed using double-blind method. Observation included: osteophytosis, changes of joint space and transverse ligament, and the clinical symptoms as well. Results: CT findings of AO joint degeneration included: formation of osteophyte, narrowing of joint space, transverse ligament calcification, and joint vacuum phenomenon. Among individuals above 40 years of age, the incidence of degeneration at AO joint went up gradually (P<0.01). Conclusion: Degeneration of AO joint was not uncommon among aged people, CT could better demonstrate the pathological changes

  11. Bibliography of published papers on neutron and photon emission from thick or thin target bombarded by charged particles

    International Nuclear Information System (INIS)

    Nakamura, Takashi; Furuta, Yutaka; Sato, Kazuo; Kawachi, Kiyomitsu; Hirayama, Hideo.

    1981-09-01

    Papers describing about secondary particles, especially neutrons and photons, produced by a thick or thin target are surveyed. The survey covers twelve kinds of journals mainly from 1965 to 1980, and brief descriptions are listed about type of accelerator, projectile and target used, measurements and calculations, and quantities obtained. (author)

  12. The role of CT in oncology irigography

    International Nuclear Information System (INIS)

    Hako, R.; Gulova, I.

    2013-01-01

    Colorectal cancer is a common malignancy that results in significant morbidity and mortality. CT irigography is an evolving noninvasive imaging technique that relies on performing thin-section CT of the colon evaluating data using both 2D and 3D images. A clean and well-distended colon facilitates detection of colorectal abnormalities whether 2D and 3D techniques are used for data interpretation. Is valuable in planning surgery for colon cancer because it can demonstrate regional extension of tumor as well as adenopathy and distant metastases. Also complications of primary colonic malignancies such as obstructions, perforations, and fistulas can be readily visualized with CT irigography. The liver is the predominant organ to be involved with metastases from colorectal cancer. Other common sites of metastases from colon cancer include the lungs, adrenal glands, and bones. CT is applicable for identifying recurrences, evaluating anatomic relationships, documenting normal postoperative anatomy, and confirming the absence of new lesions during and after therapy. (author)

  13. CT manifestations of peritoneal carcinomatosis.

    Science.gov (United States)

    Walkey, M M; Friedman, A C; Sohotra, P; Radecki, P D

    1988-05-01

    Seventy-three abdominopelvic contrast-enhanced CT scans obtained in 60 patients with peritoneal tumor spread were reviewed retrospectively to determine the CT signs of peritoneal malignancy. Ascites was present in 54 studies (74%) and was the most common CT finding. Loculation of the fluid occurred in 25 (46%) of these. In nine (17%) of the 54, a new finding, absence of cul-de-sac fluid in the presence of generalized ascites, was noted. Parietal peritoneal thickening with contrast enhancement of the peritoneum, making the peritoneum visible as a thin line along the abdominal wall, was present in 45 (62%) of studies. This is believed to represent confluent peritoneal metastases. Small-bowel involvement was present in half of the cases (wall thickening and irregularity with or without obstruction). Tumor involvement of the omentum was visible as soft-tissue permeation of fat, enhancing nodules, and/or an omental cake. Of the 26 patients without a previously known malignancy, identification of the primary tumor in addition to peritoneal carcinomatosis was possible in 13 (50%). Appreciation of the spectrum of CT findings in peritoneal carcinomatosis is essential for accurate evaluation of scans in patients with abdominopelvic malignancies.

  14. Do SNOMED CT Relationships Qualify?

    NARCIS (Netherlands)

    Cornet, Ronald

    2008-01-01

    An important feature of SNOMED CT is post-coordination, which is enabled as SNOMED CT specifies refinability of target concepts of relationships. In this paper the use of refinable relationships in SNOMED CT is analysed, and the interplay between refinable and defining relationships. Refinability is

  15. Thin-section CT vs spiral CT in candidates for lung volume reduction surgery: a comparison based on radiologists' subjective preferences

    International Nuclear Information System (INIS)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B.; Bergstrand, L.

    2001-01-01

    The aim of this study was to investigate whether high-resolution (HRCT) or spiral CT was preferred in evaluating severe emphysema in patients undergoing lung volume reduction surgery (LVRS), whether there is any difference in this regard between the cranial and caudal part of the lung, and whether the degree of emphysema has an impact on the radiologists' preference. The study was performed by letting four radiologists compare images obtained with the two techniques (film pairs) and decide which technique they preferred or if the techniques were considered as equal in evaluating emphysema. In evaluation of 188 film pairs, the HRCT images were preferred in 56 %, spiral CT in 19 % and the techniques considered as equal in 25 %. Spiral CT images were preferred more often in the caudal part of the lung and in more advanced emphysema compared with the HRCT images. The study confirms our clinical assumption that use of both CT techniques are valuable in evaluating advanced emphysema and there may be technical as well as histopathological reasons for this. (orig.)

  16. Studies on the uptake of 14C-neostigmine in the isolated rat diaphragm

    International Nuclear Information System (INIS)

    Helleberg, L.

    1976-01-01

    The uptake process of 14 C-neostigmine in striated muscles was studied using the isolated rat diaphragm. Hemidiaphragms were incubated with 3x10 -7 M 14 C-neostigmine at 37deg in Krebs-Ringer solution containing 11 mM glucose and aerated with oxygen:carbon dioxide (95:5 v/v %). The uptake, which is expressed as the muscle-to-medium concentration ratio, was 1.41, after 3 hours, after which the rate of uptake diminished and became equal to that of inulin. The uptake which showed partial saturation, was decreased by some tertiary and quarternary amines, metabolic inhibitors, potassium and in an atmosphere of nitrogen. Neostigmine accumulated in all parts of the muscle without preference for the end plate zone. The half-time for the efflux was about 30 min. The phrenic nerve-diaphragm preparation became desensitized to the effect of 3x10 -7 M neostigmine after 2-3 hours. It is suggested that the uptake of neostigmine is mediated via a specialized carrier transport system. (author)

  17. CT of laryngotracheal trauma

    International Nuclear Information System (INIS)

    Lupetin, A.R.; Daffner, R.H.

    1991-01-01

    This paper evaluates the usefulness of CT for the diagnosis of traumatic laryngotracheal abnormalities. The authors retrospectively evaluated the neck CT studies of 50 patients (36 males, 14 females; age range, 16-75 years) who presented to a level I trauma center after suffering a blunt or penetrating laryngotracheal injury. CT results were correlated with endoscopic or surgical findings in 43 cases. Three groups emerge. CT positive: hyloid bone or laryngotracheal cartilage injury; CT positive: soft-tissue injury only; and CT negative. In group 1, CT demonstrated all bony or cartilaginous injuries proved at surgery or suggested at endoscopy. CT failed to demonstrate laryngotracheal separation in 1 case. In group 2, CT demonstrated all soft-tissue injuries suggested at endoscopy. In group 3, CT findings agreed with those of endoscopy in 7 cases, but minor soft-tissue findings seen at endoscopy were missed in 3 cases. Seven patients were studied only with CT. Ct is an accurate technique for detecting bony or cartilaginous laryngotracheal traumatic abnormalities. However, laryngotracheal separation and minor soft-tissue injuries can be missed

  18. CT-Urography

    International Nuclear Information System (INIS)

    Dalla Palma, Ludovico; Grotto, Maurizio; Morra, Aldo

    2005-01-01

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography [it

  19. Co-registration between locally acquired CT and PET from a remote location

    International Nuclear Information System (INIS)

    Pilloy, W.J.; Lens, V.; Hellwig, D.; Berchem, G.

    2002-01-01

    Aim: The process of referring patients abroad for PET scan was developed in steps, and the corresponding aims were: 1) To provide enough clinical information to the PET centre for correct interpretation of the examination. 2) To transfer the PET data. 3) To optimize the CT data for co-registration. 4) To achieve a good topographical co-registration. 5) To correlate the lesions and interpret eventual discrepancies. 6) To issue a common report . Method: 1) The patients were referred to the Dept NM Saarland University Medical Center with their CT scan and a form specifying the presumptive diagnosis, a short history and the type of and delay since treatment. 2) The data were transferred by Internet to the Dept NM of CHLuxemburg; the original PET report and local PET images were loaded on their respective servers 3) The spiral CT (Dept Radiology CHL) scan was recorded over the whole trunk, supine, arms along the body, at tidal breathing or at end-expiration (diaphragm), without medication or contrast, at low mA, on a conventional palet. 4) The CT and PET data were automatically corrected for slice thickness and number; co-registration was done manually, initially starting with a recognizable transaxial slice and then progressing up and down on compressed CT data, later on interactively along 3 axes on full size CT data; co-registration was fine tuned at various levels of the trunk (Hermes). 5) The co-registered images were reviewed jointly lesion by lesion by specialists in Radiology and Nuclear Medicine; eventual discrepancies were interpreted taking into account the clinical history and the specificities of each modality. 6) A 'Correlative Imaging' report was issued. Results of 15+ co-registered lung carcinomas and 12+ lymphomas are presented. Conclusion: Correlative imaging not only improves on the localisation of PET lesions, but also on a better discrimination between malignant and benign lesions as seen either on CT or PET. Clearly the availability of other

  20. Case of multiple hepatic abscesses detected by CT scan in the patient with acute lymphoblastic leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Saburi, Yoshio; Shuto, Ryusuke; Mizutani, Ryoko; Hosokawa, Takafumi; Itoga, Takashi (Medical Coll. of Oita (Japan))

    1983-12-01

    A 34 year old man admitted to a hospital on 21 Feb. 1983 was diagnosed acute lymphoblastic leukemia. A hematological complete remission was achieved by combination therapy of vincristine, prednisolone and L-asparaginase. However, he had been complaining of high fever and right hypochondralgia since early in Apr. 1983, and it was revealed that elevation of right diaphragm on chest X-ray. Therefore, he was also given several antibiotics (CPZ, TOB, LMOX, PIPC, LCM, AMK, MINO and GM) for complication of probable liver abscess. Remittent fever persisted in spite of as mentioned above various antibiotics. The multiple hepatic abscesses were found by CT scan of the mid-abdomen as the low density lesions, but bacterial cultures detected no pathogens. His complaining of remittent fever and right hypochondralgia were improved by treatment with Miconazole during about one month, and decreasing in size and number of multiple hepatic abscesses were found by CT scan. Though we could not determine clearly, but suspected that multiple hepatic abscesses were due to fungus infection, by reason of therapeutic result. Regarding the complication of hepatic abscesses with leukemia, 5 cases have been reported in Japan, and one case out of 5 cases were detected by CT scan. We thought that CT scans were useful procedures for early diagnosis of hepatic abscesses. Recently, the patient has continued complete remission hematologically.

  1. CT urography

    Energy Technology Data Exchange (ETDEWEB)

    Korobkin, M. [Dept. of Radiology, Univ. of Michigan, Ann Arbor, MI (United States)

    2005-11-15

    With the advent of multidetector row CT scanners, evaluation of the urothelium of the entire urinary tract with high-resolution thin sections during a single breath-hold has become a reality. Multidetector CT urography (MDCTU) is a single examination that allows evaluation of potential urinary tract calculi, renal parenchymal masses, and both benign and malignant urothelial lesions. Initial results with this new technique are encouraging. Current investigations of MDCTU focus on methods to improve opacification and distension of the upper urinary tract - the collecting systems, pelvis, and ureters. The role of abdominal compression, infusion of saline and/or furosemide, and optimal time delay of excretory phase imaging is being explored. Upper tract urothelial malignancies, including small lesions less the 5 mmin diameter, can be detected with high sensitivity. Methods to reduce radiation exposure are being explored, including split-bolus contrast injection techniques that combine nephrographic and excretory phases into a single phase. It is likely that in the near future, radiological evaluation of significant unexplained hematuria or of known or prior urothelial malignancy will consist of a single examination - MDCTU. (orig.)

  2. CT evaluation of acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Piazza, P; Girelli, G; Coran, F; Lutman, M

    1986-01-01

    The paper deals with sixteen cases of acetabular fractures studied with CT. After a short description of the normal CT findings, the different kind of fractures are reported. The usefulness of CT examination in evaluating acetabular fractures and their complications is confirmed both in conservative treatment and surgical approach.

  3. New reconstruction algorithm in helical-volume CT

    International Nuclear Information System (INIS)

    Toki, Y.; Rifu, T.; Aradate, H.; Hirao, Y.; Ohyama, N.

    1990-01-01

    This paper reports on helical scanning that is an application of continuous scanning CT to acquire volume data in a short time for three-dimensional study. In a helical scan, the patient couch sustains movement during continuous-rotation scanning and then the acquired data is processed to synthesize a projection data set of vertical section by interpolation. But the synthesized section is not thin enough; also, the image may have artifacts caused by couch movement. A new reconstruction algorithm that helps resolve such problems has been developed and compared with the ordinary algorithm. The authors constructed a helical scan system based on TCT-900S, which can perform 1-second rotation continuously for 30 seconds. The authors measured section thickness using both algorithms on an AAPM phantom, and we also compared degree of artifacts on clinical data

  4. Recovery of muscle function after deep neuromuscular block by means of diaphragm ultrasonography and adductor of pollicis acceleromyography with comparison of neostigmine vs. sugammadex as reversal drugs: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Cappellini, Iacopo; Picciafuochi, Fabio; Ostento, Daniele; Danti, Ginevra; De Gaudio, Angelo Raffaele; Adembri, Chiara

    2018-02-21

    block between patients who receive neostigmine and those who receive sugammadex. Postoperative residual curarization is a topic of paramount importance, because its occurrence can cause complications and increase the length of stay in hospital and the related costs. Diaphragm ultrasound assessment may become a bedside integrative tool in the neuromuscular monitoring field to detect concealed residual curarization in surgical patients who have received paralyzing agents. EudraCT, 2013-004787-62. Registered on 18 June 2014, as "Evaluation of muscle function recovery after deep neuromuscular blockade by acceleromyography of the adductor pollicis or diaphragmatic echography: comparison between sugammadex and neostigmine." ClinicalTrials.gov, NCT02698969 . Registered on 15 February 2016, as "Recovery of Muscle Function After Deep Neuromuscular Block by Means of Diaphragm Ultrasonography and Adductor Pollicis Acceleromyography: Comparison of Neostigmine vs. Sugammadex as Reversal Drugs."

  5. Improving Intensity-Based Lung CT Registration Accuracy Utilizing Vascular Information

    Directory of Open Access Journals (Sweden)

    Kunlin Cao

    2012-01-01

    Full Text Available Accurate pulmonary image registration is a challenging problem when the lungs have a deformation with large distance. In this work, we present a nonrigid volumetric registration algorithm to track lung motion between a pair of intrasubject CT images acquired at different inflation levels and introduce a new vesselness similarity cost that improves intensity-only registration. Volumetric CT datasets from six human subjects were used in this study. The performance of four intensity-only registration algorithms was compared with and without adding the vesselness similarity cost function. Matching accuracy was evaluated using landmarks, vessel tree, and fissure planes. The Jacobian determinant of the transformation was used to reveal the deformation pattern of local parenchymal tissue. The average matching error for intensity-only registration methods was on the order of 1 mm at landmarks and 1.5 mm on fissure planes. After adding the vesselness preserving cost function, the landmark and fissure positioning errors decreased approximately by 25% and 30%, respectively. The vesselness cost function effectively helped improve the registration accuracy in regions near thoracic cage and near the diaphragm for all the intensity-only registration algorithms tested and also helped produce more consistent and more reliable patterns of regional tissue deformation.

  6. Fabrication of polymer micro-lens array with pneumatically diaphragm-driven drop-on-demand inkjet technology.

    Science.gov (United States)

    Xie, Dan; Zhang, Honghai; Shu, Xiayun; Xiao, Junfeng

    2012-07-02

    The paper reports an effective method to fabricate micro-lens arrays with the ultraviolet-curable polymer, using an original pneumatically diaphragm-driven drop-on-demand inkjet system. An array of plano convex micro-lenses can be formed on the glass substrate due to surface tension and hydrophobic effect. The micro-lens arrays have uniform focusing function, smooth and real planar surface. The fabrication process showed good repeatability as well, fifty micro-lenses randomly selected form 9 × 9 miro-lens array with an average diameter of 333.28μm showed 1.1% variations. Also, the focal length, the surface roughness and optical property of the fabricated micro-lenses are measured, analyzed and proved satisfactory. The technique shows great potential for fabricating polymer micro-lens arrays with high flexibility, simple technological process and low production cost.

  7. Study on the onset of DC diaphragm glow discharge

    International Nuclear Information System (INIS)

    Jin, Xinglong; Wang, Xiaoyan; Zhang, Hongmei; Ren, Hongxia

    2013-01-01

    In this paper, the DC diaphragm glow discharge (DGD) occurred around the small hole on quartz tube between two submersed graphite electrodes and the onset of DGD was systematically investigated. It was found that critical voltage (V D ) decreased with the increasing conductivity, and then maintained at about 620 V. When the hole diameter increased from 1.0 mm to 2.5 mm, H 2 O 2 formation and AO discoloration in anolyte increased with the increase of the hole diameter. In addition, the effect of electrolyte constituents on H 2 O 2 formation and AO discoloration in anolyte induced by DGD was also studied. The concentration of H 2 O 2 and AO discoloration in anolyte was close in inert electrolyte such as Na 2 SO 4 and Na 2 HPO 4 solution. The concentration of H 2 O 2 and AO discoloration rate in Na 2 CO 3 and NaAc solution was lower than those in Na 2 SO 4 and Na 2 HPO 4 solution, due to their capture ability for ·OH. However, NaCl showed enhancing effect on AO discoloration, although it consumed a certain amount of H 2 O 2 . The energy efficiencies of AO discoloration and H 2 O 2 formation were also compared with those of other DGD reactor.

  8. Pulmonary light-chain deposition disease: CT and pathology findings in nine patients

    International Nuclear Information System (INIS)

    Sheard, S.; Nicholson, A.G.; Edmunds, L.; Wotherspoon, A.C.; Hansell, D.M.

    2015-01-01

    Aim: To review the clinical features of nine patients with pulmonary light-chain deposition disease (LCDD) and record their high-resolution CT (HRCT) and histopathological findings. Materials and methods: Patients with a diagnosis of LCDD on lung biopsy specimen were retrospectively identified. The HRCT characteristics of nodules, cysts, and ancillary findings; change at follow-up; and histopathological findings were documented. Results: Features common to all nine cases were thin-walled cysts. In seven cases, vessels traversing the cysts were identified. The majority of patients (8/9) had at least one pulmonary nodule. There was no zonal predominance of either cysts or nodules. The disease appeared stable in the majority of cases with no serial change in HRCT appearances (5/6 cases with follow-up data, mean duration 29 months). Conclusion: To the authors' knowledge, this is the largest series of pulmonary LCDD patients in the literature, and the first systematic assessment of HRCT findings. Pulmonary cysts are a unifying feature, usually with pulmonary nodules, and serial change on HRCT is unusual. - Highlights: • Nine cases of pulmonary light chain deposition disease with high-resolution CT. • CT scans assessed for abnormal features. • Clinical data and histopathological findings obtained. • All patients had thin-walled cysts on CT, often with traversing vessels. • CT features of disease in this group are cysts, nodules and an indolent course

  9. Dynamic performance analysis of diaphragm coupling base on ABAQUS

    Directory of Open Access Journals (Sweden)

    You Wen

    2017-04-01

    Full Text Available Base on the diaphragm coupling of driving system of a rotation testing machine,FEA software ABAQUS is used to simulate the force which the coupling gets when it is working,to obtain the stress and stain during the coupling with axial misalignment and degree misalignment and to find where the maximal stress is as well as its distribution.Then the nature frequency of the coupling is calculated by use of finite element software and rotor dynamics and compared with the date of misalignment and maximum speed from the manufacture,which verifies the correctness of the model and the reliability of the calculation method.

  10. Nonvolatile memory thin-film transistors using biodegradable chicken albumen gate insulator and oxide semiconductor channel on eco-friendly paper substrate.

    Science.gov (United States)

    Kim, So-Jung; Jeon, Da-Bin; Park, Jung-Ho; Ryu, Min-Ki; Yang, Jong-Heon; Hwang, Chi-Sun; Kim, Gi-Heon; Yoon, Sung-Min

    2015-03-04

    Nonvolatile memory thin-film transistors (TFTs) fabricated on paper substrates were proposed as one of the eco-friendly electronic devices. The gate stack was composed of chicken albumen gate insulator and In-Ga-Zn-O semiconducting channel layers. All the fabrication processes were performed below 120 °C. To improve the process compatibility of the synthethic paper substrate, an Al2O3 thin film was introduced as adhesion and barrier layers by atomic layer deposition. The dielectric properties of biomaterial albumen gate insulator were also enhanced by the preparation of Al2O3 capping layer. The nonvolatile bistabilities were realized by the switching phenomena of residual polarization within the albumen thin film. The fabricated device exhibited a counterclockwise hysteresis with a memory window of 11.8 V, high on/off ratio of approximately 1.1 × 10(6), and high saturation mobility (μsat) of 11.5 cm(2)/(V s). Furthermore, these device characteristics were not markedly degraded even after the delamination and under the bending situration. When the curvature radius was set as 5.3 cm, the ION/IOFF ratio and μsat were obtained to be 5.9 × 10(6) and 7.9 cm(2)/(V s), respectively.

  11. A case of multiple hepatic abscesses detected by CT scan in the patient with acute lymphoblastic leukemia

    International Nuclear Information System (INIS)

    Saburi, Yoshio; Shuto, Ryusuke; Mizutani, Ryoko; Hosokawa, Takafumi; Itoga, Takashi

    1983-01-01

    A 34 years old man admitted to a hospital on 21 Feb. 1983 and was diagnosed acute lymphoblastic leukemia. A hematological complete remission was achieved by combination therapy of vincristine, prednisolone and L-asparaginase. However, he had complaining of high fever and right hypochondralgia since early in Apr. 1983, and it was revealed that elevation of right diaphragm on chest X-ray. Therefore, he was also given several antibiotics (CPZ, TOB, LMOX, PIPC, LCM, AMK, MINO and GM) for complication of probable liver abscess. Remittent fever was persisted in spite of as mentioned above various antibiotics. The multiple hepatic abscesses were found by CT scan of the mid-abdomen as the low density lesions, but bacterial cultures detected no any pathogens. His complaining of remittent fever and right hypochondralgia were improved by treated with Miconazole during about one month, and decreasing in size and number of multiple hepatic abscesses were found by CT scan. Though we could not determined clearly, but suspected that, multiple hepatic abscesses were due to fungus infection, by reason of therapeutic result. Regarding the complication of hepatic abscesses with leukemia, 5 cases have been reported in Japan, and one case out of 5 cases were detected by CT scan. We thought that CT scan were useful procedure for a early diagnosis of hepatic abscesses. In recently, the patient has continued of complete remission hematologically. (author)

  12. Multidetector CT portal venography in evaluation of portosystemic collateral vessels

    International Nuclear Information System (INIS)

    Agarwal, A.; Jain, M.

    2008-01-01

    This essay shows the usefulness of multidetector CT angiography for evaluation of the splenoportal venous system, which is essential in the management of patients with portal hypertension and its complications, such as portal vein thrombosis. By providing scanning with reconstruction of thin axial source images and reformatting into thicker multiplanar reformats, multidetector CT can help to determine the extent and location of portosystemic collateral vessels in patients with portal hypertension and is probably the optimal imaging technique in this setting.

  13. Comparison of stethoscope bell and diaphragm, and of stethoscope tube length, for clinical blood pressure measurement.

    Science.gov (United States)

    Liu, Chengyu; Griffiths, Clive; Murray, Alan; Zheng, Dingchang

    2016-06-01

    This study investigated the effect of stethoscope side and tube length on auscultatory blood pressure (BP) measurement. Thirty-two healthy participants were studied. For each participant, four measurements with different combinations of stethoscope characteristics (bell or diaphragm side, standard or short tube length) were each recorded at two repeat sessions, and eight Korotkoff sound recordings were played twice on separate days to one experienced listener to determine the systolic and diastolic BPs (SBP and DBP). Analysis of variance was carried out to study the measurement repeatability between the two repeat sessions and between the two BP determinations on separate days, as well as the effects of stethoscope side and tube length. There was no significant paired difference between the repeat sessions and between the repeat determinations for both SBP and DBP (all P-values>0.10, except the repeat session for SBP using short tube and diaphragm). The key result was that there was a small but significantly higher DBP on using the bell in comparison with the diaphragm (0.66 mmHg, P=0.007), and a significantly higher SBP on using the short tube in comparison with the standard length (0.77 mmHg, P=0.008). This study shows that stethoscope characteristics have only a small, although statistically significant, influence on clinical BP measurement. Although this helps understand the measurement technique and resolves questions in the published literature, the influence is not clinically significant.

  14. Lipid intermediates in membrane fusion: formation, structure, and decay of hemifusion diaphragm.

    Science.gov (United States)

    Kozlovsky, Yonathan; Chernomordik, Leonid V; Kozlov, Michael M

    2002-11-01

    Lipid bilayer fusion is thought to involve formation of a local hemifusion connection, referred to as a fusion stalk. The subsequent fusion stages leading to the opening of a fusion pore remain unknown. The earliest fusion pore could represent a bilayer connection between the membranes and could be formed directly from the stalk. Alternatively, fusion pore can form in a single bilayer, referred to as hemifusion diaphragm (HD), generated by stalk expansion. To analyze the plausibility of stalk expansion, we studied the pathway of hemifusion theoretically, using a recently developed elastic model. We show that the stalk has a tendency to expand into an HD for lipids with sufficiently negative spontaneous splay, (~)J(s)action of an external force pulling the diaphragm rim apart. We calculate the dependence of the HD radius on this force. To address the mechanism of fusion pore formation, we analyze the distribution of the lateral tension emerging in the HD due to the establishment of lateral equilibrium between the deformed and relaxed portions of lipid monolayers. We show that this tension concentrates along the HD rim and reaches high values sufficient to rupture the bilayer and form the fusion pore. Our analysis supports the hypothesis that transition from a hemifusion to a fusion pore involves radial expansion of the stalk.

  15. Thin-section CT vs spiral CT in candidates for lung volume reduction surgery: a comparison based on radiologists' subjective preferences

    Energy Technology Data Exchange (ETDEWEB)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B. [Dept. of Thoracic Radiology, Karolinska Hospital, Stockholm (Sweden); Bergstrand, L. [Dept. of Radiology, Danderyds Hospital (Sweden)

    2001-03-01

    The aim of this study was to investigate whether high-resolution (HRCT) or spiral CT was preferred in evaluating severe emphysema in patients undergoing lung volume reduction surgery (LVRS), whether there is any difference in this regard between the cranial and caudal part of the lung, and whether the degree of emphysema has an impact on the radiologists' preference. The study was performed by letting four radiologists compare images obtained with the two techniques (film pairs) and decide which technique they preferred or if the techniques were considered as equal in evaluating emphysema. In evaluation of 188 film pairs, the HRCT images were preferred in 56 %, spiral CT in 19 % and the techniques considered as equal in 25 %. Spiral CT images were preferred more often in the caudal part of the lung and in more advanced emphysema compared with the HRCT images. The study confirms our clinical assumption that use of both CT techniques are valuable in evaluating advanced emphysema and there may be technical as well as histopathological reasons for this. (orig.)

  16. Paranasal sinuses and nasopharynx CT and MRI

    International Nuclear Information System (INIS)

    Sievers, K.W.; Greess, H.; Baum, U.; Dobritz, M.; Lenz, M.

    2000-01-01

    Neoplastic disease of the nose, paranasal sinuses, the nasopharynx and the parapharyngeal space requires thorough assessment of location and extent in order to plan appropriate treatment. CT allows the deep soft tissue planes to be evaluated and provides a complement to the physical examination. It is especially helpful in regions involving thin bony structures (paranasal sinuses, orbita); here CT performs better than MRI. MRI possesses many advantages over other imaging modalities caused by its excellent tissue contrast. In evaluating regions involving predominantly soft tissue structures (ec nasopharynx and parapharyngeal space) MRI is superior to CT. The possibility to obtain strictly consecutive volume data sets with spiral CT or 3D MRI offer excellent perspectives to visualize the data via 2D or 3D postprocessing. Because head and neck tumors reside in a complex area, having a 3D model of the anatomical features may assist in the delineation of pathology. Data sets may be transferred directly into computer systems and thus be used in computer assisted surgery

  17. Paranasal sinuses and nasopharynx CT and MRI.

    Science.gov (United States)

    Sievers, K W; Greess, H; Baum, U; Dobritz, M; Lenz, M

    2000-03-01

    Neoplastic disease of the nose, paranasal sinuses, the nasopharynx and the parapharyngeal space requires thorough assessment of location and extent in order to plan appropriate treatment. CT allows the deep soft tissue planes to be evaluated and provides a complement to the physical examination. It is especially helpful in regions involving thin bony structures (paranasal sinuses, orbita); here CT performs better than MRI. MRI possesses many advantages over other imaging modalities caused by its excellent tissue contrast. In evaluating regions involving predominantly soft tissue structures (ec nasopharynx and parapharyngeal space) MRI is superior to CT. The possibility to obtain strictly consecutive volume data sets with spiral CT or 3D MRI offer excellent perspectives to visualize the data via 2D or 3D postprocessing. Because head and neck tumors reside in a complex area, having a 3D model of the anatomical features may assist in the delineation of pathology. Data sets may be transferred directly into computer systems and thus be used in computer assisted surgery.

  18. Midbrain and medullary control of postinspiratory activity of the crural and costal diaphragm in vivo

    NARCIS (Netherlands)

    Subramanian, Hari H.; Holstege, Gert

    Subramanian HH, Holstege G. Midbrain and medullary control of postinspiratory activity of the crural and costal diaphragm in vivo. J Neurophysiol 105: 2852-2862, 2011. First published March 30, 2011; doi:10.1152/jn.00168.2011.-Studies on brain stem respiratory neurons suggest that eupnea consists of

  19. Genetic specification of left–right asymmetry in the diaphragm muscles and their motor innervation

    Science.gov (United States)

    Charoy, Camille; Dinvaut, Sarah; Chaix, Yohan; Morlé, Laurette; Sanyas, Isabelle; Bozon, Muriel; Kindbeiter, Karine; Durand, Bénédicte; Skidmore, Jennifer M; De Groef, Lies; Seki, Motoaki; Moons, Lieve; Ruhrberg, Christiana; Martin, James F; Martin, Donna M; Falk, Julien; Castellani, Valerie

    2017-01-01

    The diaphragm muscle is essential for breathing in mammals. Its asymmetric elevation during contraction correlates with morphological features suggestive of inherent left–right (L/R) asymmetry. Whether this asymmetry is due to L versus R differences in the muscle or in the phrenic nerve activity is unknown. Here, we have combined the analysis of genetically modified mouse models with transcriptomic analysis to show that both the diaphragm muscle and phrenic nerves have asymmetries, which can be established independently of each other during early embryogenesis in pathway instructed by Nodal, a morphogen that also conveys asymmetry in other organs. We further found that phrenic motoneurons receive an early L/R genetic imprint, with L versus R differences both in Slit/Robo signaling and MMP2 activity and in the contribution of both pathways to establish phrenic nerve asymmetry. Our study therefore demonstrates L–R imprinting of spinal motoneurons and describes how L/R modulation of axon guidance signaling helps to match neural circuit formation to organ asymmetry. DOI: http://dx.doi.org/10.7554/eLife.18481.001 PMID:28639940

  20. Change in concentration of inorganic phosphate and phosphocreatine in the rat diaphragm under the influence of whole-body gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Mansour, M A; Gaber, M; Abdel-Fatah, K I

    1987-01-01

    The influence of irradiation on the concentration of creatine phosphate and inorganic phosphate in the diaphragm muscle were studied in rats exposed to 400 rad and 800 rad whole-body gamma radiation. The results showed that on the first day of post-exposure with 400 rad, the creatine phosphate concentration significantly increased, while the level significantly decreased on the third up to the fourteenth days of post exposure. In animals exposed to 800 rad, the diaphragm phosphocreatine showed a significant decrease on the first up to the ninth day post-irradiation as compared with the control group.

  1. Change in concentration of inorganic phosphate and phosphocreatine in the rat diaphragm under the influence of whole-body gamma irradiation

    International Nuclear Information System (INIS)

    Mansour, M.A.; Gaber, M.; Abdel-Fatah, K.I.

    1987-01-01

    The influence of irradiation on the concentration of creatine phosphate and inorganic phosphate in the diaphragm muscle were studied in rats exposed to 400 rad and 800 rad whole-body gamma radiation. The results showed that on the first day of post-exposure with 400 rad, the creatine phosphate concentration significantly increased, while the level significantly decreased on the third up to the fourteenth days of post exposure. In animals exposed to 800 rad, the diaphragm phosphocreatine showed a significant decrease on the first up to the ninth day post-irradiation as compared with the control group

  2. Large Epiphrenic Diverticulum with Perforation and Leakage below the Diaphragm

    DEFF Research Database (Denmark)

    Brønserud, Majken Munk; Brenøe, Anne-Sofie; Eckardt, Jens

    2015-01-01

    contrast revealed contrast leakage near the minor curvature of the stomach. The following esophagogastroduodenoscopy demonstrated a giant dilatation of the esophagus, as well as a second esophageal lumen originating 25 cm from the incisors. The “false” lumen of the esophagus was located parallel...... to esophagus, ending blindly in a perforation below the diaphragm. The clinical presentation and the patient’s age make it most likely, that it was a long epiphrenic diverticulum of pulsion type. The patient was treated conservatively, discharged after 10 days and has been followed in our outpatient clinic...... for 8 months, until he died of aggressive pulmonary cancer....

  3. Liver hydatid cyst ruptured into the thorax: CT angiography findings of a case

    International Nuclear Information System (INIS)

    Kara, K.; Ors, F.; Bozlar, U.; Tasar, M.

    2012-01-01

    Full text: Introduction: Intrathoracic rupture of hepatic hydatid cyst is a rare but severe condition causing a spectrum of lesions to the pleura, lung parenchyma, and bronchi. Pulmonary complications result from the proximity of hydatid cysts in the liver and the diaphragm. Objectives and tasks: In this report we aimed to present computed tomography (CT) angiography findings of a case with liver hydatid cyst ruptured into the thorax. The patient underwent CT angiography examination with suspicion of pulmonary embolism. Materials and methods: A 71-year-old female patient admitted to our emergency department with complaints of severe and persistent cough. Basal region of the right hemithorax could not get breath sounds on physical examination. Chest radiography revealed the presence of consolidation-effusion. The patient was treated with antibiotherapy for pneumonia and parapneumonic effusion. Because of the clinical symptoms and chest radiograph findings persisted the patient underwent CT angiography examination with suspicion of pulmonary embolism. Results: On CT angiography images pulmonary artery and its branches were normal. There were subtotal collapse in the right middle and lower lung lobes and complicated cystic lesion that has air densities in the basal interlobar space. Another thick walled complicated cystic lesion with multiple septations and air densities was detected in the right posterior liver lobe. The right hemidiaphragm was interrupted and the right liver lobe partially herniated into the thorax cavity. Serologic tests were positive for Echinococcus granulosus and there were prior therapy history for liver cyst hydatid. The diagnostic aspiration findings were consistent with hydatid cyst lesion. Conclusion: In patients with hepatic hydatid cyst associated with persistent and severe cough, thoracic rupture of the cyst should be considered in differential diagnosis. CT angiography is fast, non-invasive and effective method in the detection of

  4. Evaluation of small peripheral pulmonary lesions with thin slice computed tomography

    International Nuclear Information System (INIS)

    Yamada, Kouzo

    1992-01-01

    To evaluate the morphology of small peripheral pulmonary lesions, we studied thin-slice CT (TS-CT) images of 47 small peripheral pulmonary lesions (24 lung cancers, 23 benign lesions) in 47 patients. CT images were examined by two different window and level settings (window level; -600, window width; 1900 and window level; 50, window width; 300). In TS-CT images, findings of all lesions were classified into 3 different patterns (infiltrative type, solid with air-bronchogram type, homogeneous solid type) which were useful in diagnosing histology based on the growth pattern of the lesion. There was no lung cancer case in which calcification was diagnosed to be present on TS-CT. On the other hand, 5 of 9 inflammatory granulomas were recognized to contain calcium which was never seen on conventional CT. The results suggest that TS-CT may have a significant clinical role in diagnosing small peripheral pulmonary lesion by demonstrating macroscopic features and calcification. (author)

  5. X fluorescence spectrometer including at least one toroidal monochromator with logarithmic spiral

    International Nuclear Information System (INIS)

    Florestan, J.

    1986-01-01

    This spectrometer includes a X-ray source, an entrance diaphragm, a revolution monochromator with monocrystal thin plates and a seal set in its center, an outer diaphragm and a X-ray detector. A second monochromator can be set between the source and the sample. The thin plates are set so as to be a toroidal ring whose cross section in an axial plane describes a logarithmic spiral [fr

  6. Pulmonary sarcoidosis: morphologic associations of airflow obstruction at thin section CT

    International Nuclear Information System (INIS)

    Hansel DM; Milne DS; Lwilher M; Wells AU

    1999-01-01

    The present study tries to determine the consequences and the correlation between the lung function and the scannographic patron to guide toward the understanding of the possible mechanisms responsible for the obstruction of the air roads in the sarcoidosis. A prospective study was carried out during two years in 45 patients, 27 of masculine sex, the discoveries of the CT were classified in five states, according to the commitment parenchymatose with or without commitment ganglionar, to the calculation of the committed lung volume and the description of radiological patterns as attenuation diminished in mosaic pattern, burnished glass, nodules, obscurely with or without air bronchogramma and reticular pattern. To all the patients they were carried out tests of lung function in the same month of the taking of the CT

  7. Experimental validation of the tuneable diaphragm effect in modern acoustic stethoscopes.

    Science.gov (United States)

    Nowak, Karolina M; Nowak, Lukasz J

    2017-09-01

    The force with which the diaphragm chestpiece of a stethoscope is pressed against the body of a patient during an auscultation examination introduces the initial stress and deformation to the diaphragm and the underlying tissues, thus altering the acoustic parameters of the sound transmission path. If the examination is performed by an experienced physician, he will intuitively adjust the amount of the force in order to achieve the optimal sound quality. However, in case of becoming increasingly popular auto-diagnosis and telemedicine auscultation devices with no such feedback mechanisms, the question arises regarding the influence of the possible force mismatch on the parameters of the recorded signal. The present study describes the results of the experimental investigations on the relation between pressure applied to the chestpiece of a stethoscope and parameters of the transmitted bioacoustic signals. The experiments were carried out using various stethoscopes connected to a force measurement system, which allowed to maintain fixed pressure during auscultation examinations. The signals were recorded during examinations of different volunteers, at various auscultation sites. The obtained results reveal strong individual and auscultation-site variability. It is concluded that the underlying tissue deformation is the primary factor that alters the parameters of the recorded signals. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. CT colonography: Techniques, indications, findings

    International Nuclear Information System (INIS)

    Mang, Thomas; Graser, Anno; Schima, Wolfgang; Maier, Andrea

    2007-01-01

    Computed tomographic colonography (CTC) is a minimally invasive technique for imaging the entire colon. Based on a helical thin-section CT of the cleansed and air-distended colon, two-dimensional and three-dimensional projections are used for image interpretation. Several clinical improvements in patient preparation, technical advances in CT, and new developments in evaluation software have allowed CTC to develop into a powerful diagnostic tool. It is already well established as a reliable diagnostic tool in symptomatic patients. Many experts currently consider CTC a comparable alternative to conventional colonoscopy, although there is still debate about its sensitivity for the detection of colonic polyps in a screening population. This article summarizes the main indications, the current techniques in patient preparation, data acquisition and data analysis as well as imaging features for common benign and malignant colorectal lesions

  9. Fully automated intrinsic respiratory and cardiac gating for small animal CT

    Energy Technology Data Exchange (ETDEWEB)

    Kuntz, J; Baeuerle, T; Semmler, W; Bartling, S H [Department of Medical Physics in Radiology, German Cancer Research Center, Heidelberg (Germany); Dinkel, J [Department of Radiology, German Cancer Research Center, Heidelberg (Germany); Zwick, S [Department of Diagnostic Radiology, Medical Physics, Freiburg University (Germany); Grasruck, M [Siemens Healthcare, Forchheim (Germany); Kiessling, F [Chair of Experimental Molecular Imaging, RWTH-Aachen University, Medical Faculty, Aachen (Germany); Gupta, R [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)], E-mail: j.kuntz@dkfz.de

    2010-04-07

    A fully automated, intrinsic gating algorithm for small animal cone-beam CT is described and evaluated. A parameter representing the organ motion, derived from the raw projection images, is used for both cardiac and respiratory gating. The proposed algorithm makes it possible to reconstruct motion-corrected still images as well as to generate four-dimensional (4D) datasets representing the cardiac and pulmonary anatomy of free-breathing animals without the use of electrocardiogram (ECG) or respiratory sensors. Variation analysis of projections from several rotations is used to place a region of interest (ROI) on the diaphragm. The ROI is cranially extended to include the heart. The centre of mass (COM) variation within this ROI, the filtered frequency response and the local maxima are used to derive a binary motion-gating parameter for phase-sensitive gated reconstruction. This algorithm was implemented on a flat-panel-based cone-beam CT scanner and evaluated using a moving phantom and animal scans (seven rats and eight mice). Volumes were determined using a semiautomatic segmentation. In all cases robust gating signals could be obtained. The maximum volume error in phantom studies was less than 6%. By utilizing extrinsic gating via externally placed cardiac and respiratory sensors, the functional parameters (e.g. cardiac ejection fraction) and image quality were equivalent to this current gold standard. This algorithm obviates the necessity of both gating hardware and user interaction. The simplicity of the proposed algorithm enables adoption in a wide range of small animal cone-beam CT scanners.

  10. Rib fracture after stereotactic radiotherapy on follow-up thin-section computed tomography in 177 primary lung cancer patients

    International Nuclear Information System (INIS)

    Nambu, Atsushi; Tominaga, Lichto; Maehata, Yoshiyasu; Sawada, Eiichi; Araki, Tsutomu; Onishi, Hiroshi; Aoki, Shinichi; Koshiishi, Tsuyota; Kuriyama, Kengo; Komiyama, Takafumi; Marino, Kan; Araya, Masayuki; Saito, Ryo

    2011-01-01

    Chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer has recently been reported. However, its detailed imaging findings are not clarified. So this study aimed to fully characterize the findings on computed tomography (CT), appearance time and frequency of chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer A total of 177 patients who had undergone SRT were prospectively evaluated for periodical follow-up thin-section CT with special attention to chest wall injury. The time at which CT findings of chest wall injury appeared was assessed. Related clinical symptoms were also evaluated. Rib fracture was identified on follow-up CT in 41 patients (23.2%). Rib fractures appeared at a mean of 21.2 months after the completion of SRT (range, 4 -58 months). Chest wall edema, thinning of the cortex and osteosclerosis were findings frequently associated with, and tending to precede rib fractures. No patients with rib fracture showed tumors > 16 mm from the adjacent chest wall. Chest wall pain was seen in 18 of 177 patients (10.2%), of whom 14 patients developed rib fracture. No patients complained of Grade 3 or more symptoms. Rib fracture is frequently seen after SRT for lung cancer on CT, and is often associated with chest wall edema, thinning of the cortex and osteosclerosis. However, related chest wall pain is less frequent and is generally mild if present

  11. Sensory and motor innervation of the crural diaphragm by the vagus nerves.

    Science.gov (United States)

    Young, Richard L; Page, Amanda J; Cooper, Nicole J; Frisby, Claudine L; Blackshaw, L Ashley

    2010-03-01

    During gastroesophageal reflux, transient lower esophageal sphincter relaxation and crural diaphragm (CD) inhibition occur concomitantly. Modifying vagus nerve control of transient lower esophageal sphincter relaxation is a major focus of development of therapeutics for gastroesophageal reflux disease, but neural mechanisms that coordinate the CD are poorly understood. Nerve tracing and immunolabeling were used to assess innervation of the diaphragm and lower esophageal sphincter in ferrets. Mechanosensory responses of vagal afferents in the CD and electromyography responses of the CD were recorded in novel in vitro preparations and in vivo. Retrograde tracing revealed a unique population of vagal CD sensory neurons in nodose ganglia and CD motor neurons in brainstem vagal nuclei. Anterograde tracing revealed specialized vagal endings in the CD and phrenoesophageal ligament-sites of vagal afferent mechanosensitivity recorded in vitro. Spontaneous electromyography activity persisted in the CD following bilateral phrenicotomy in vivo, while vagus nerve stimulation evoked electromyography responses in the CD in vitro and in vivo. We conclude that vagal sensory and motor neurons functionally innervate the CD and phrenoesophageal ligament. CD vagal afferents show mechanosensitivity to distortion of the gastroesophageal junction, while vagal motor neurons innervate both CD and distal esophagus and may represent a common substrate for motor control of the reflux barrier. Copyright 2010 AGA Institute. Published by Elsevier Inc. All rights reserved.

  12. Micro-CT analyses of historical bone samples presenting with osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Lamm, C.; Pietschmann, P. [Medical University Vienna (MUV), Department of Pathophysiology and Allergy Research, Center for Pathophysiology, Infectiology and Immunology, Vienna (Austria); Dockner, M.; Weber, G.W. [University of Vienna, Department of Anthropology, Vienna (Austria); University of Vienna, Core Facility for Micro-Computed Tomography, Vienna (Austria); Pospischek, B.; Winter, E.; Patzak, B. [Museum of Natural History (NHM), Collection of Anatomical Pathology in the Madhouse Tower, Vienna (Austria); Pretterklieber, M. [Medical University of Vienna (MUV), Department of Applied Anatomy, Vienna (Austria)

    2015-10-15

    Osteomyelitis is an inflammation of the bone marrow mainly caused by bacteria such as Staphylococcus aureus. It typically affects long bones, e.g. femora, tibiae and humeri. Recently micro-computed tomography (μCT) techniques offer the opportunity to investigate bone micro-architecture in great detail. Since there is no information on long bone microstructure in osteomyelitis, we studied historic bone samples with osteomyelitis by μCT. We investigated 23 femora of 22 individuals suffering from osteomyelitis provided by the Collection of Anatomical Pathology, Museum of Natural History, Vienna (average age 44 ±19 years); 9 femora from body donors made available by the Department of Applied Anatomy, Medical University of Vienna (age range, 56-102 years) were studied as controls. Bone microstructure was assessed by μCT VISCOM X 8060 II with a minimal resolution of 18 μm. In the osteomyelitic femora, most prominent alterations were seen in the cortical compartment. In 71.4 % of the individuals with osteomyelitis, cortical porosity occurred. 57.1 % of the individuals showed cortical thinning. In 42.9 % trabecularisation of cortical bone was observed. Osteomyelitis is associated with severe alterations of cortical bone structure otherwise typically observed at old age such as cortical porosity and cortical thinning. (orig.)

  13. The impact of PET-CT in suspected recurrent ovarian cancer: A prospective multi-centre study as part of the Australian PET Data Collection Project.

    Science.gov (United States)

    Fulham, M J; Carter, J; Baldey, A; Hicks, R J; Ramshaw, J E; Gibson, M

    2009-03-01

    To assess the impact of FDG PET-CT on the management of patients with suspected recurrent ovarian cancer and to determine the incremental information provided by PET-CT. This was a prospective, multi-centre, cohort study. Ninety women (mean age 59.9 years; age range 35-85 years) with a previous history of treated epithelial ovarian carcinoma and suspected recurrence based on elevated CA-125, anatomical imaging or clinical symptoms were studied with FDG PET-CT across two States. Referring doctors were asked to specify a management plan pre-PET, if management was altered after PET-CT and, the impact (rated - none, low, medium, high) of PET-CT on patient management. The pre-PET management plan could include radiotherapy, chemotherapy, surgery, and 'other' including observation. Patients were followed at 6 and 12 months and clinical status, evidence of recurrence and progression were recorded. Patients were referred by 34 individual specialists. At least 168 additional sites of disease in 61 patients (68%), not identified by conventional imaging were identified by PET-CT. In 77% the additional lesions were located below the diaphragm and most were nodal or peritoneal. PET-CT affected management in 60% (49% high, 11% medium impact). Patients where more disease was detected with PET-CT were more likely to progress in the following 12 months. For women with previously treated ovarian carcinoma with recurrent disease, PET-CT can: a) alter management in close to 60% of patients, b) detect more sites of disease than abdominal and pelvic CT, c) is superior in the detection of nodal, peritoneal and subcapsular liver disease and d) offers the opportunity for technology replacement in this setting.

  14. CT of pancreatitis

    International Nuclear Information System (INIS)

    Fukuda, Toshio

    1990-01-01

    One hundred and two cases of acute and chronic pancreatitis were studied by computed tomography. Fluid collection was detected by CT in 45 cases, and the common extrapancreatic sites of involvement included the lesser sac (13 cases), anterior pararenal space (9 cases), transverse mesocolon (7 cases) and posterior pararenal space (5 cases). Ten cases of spontaneous resolution of pancreatic pseudocysts were encountered. Cystojejunostomy was done on 6 patients. A 4-to-6-weeks time interval has been currently accepted as necessary for pseudocyst wall maturation. However, the surgery was not possible in two patients in this series since the cyst wall was too thin. It is considered that the time over 3 months is required for surgical anastomosis of the cyst to the gastrointestinal tract. Pancreatic abscess has become the most common cause of death from pancreatitis. In this series pancreatic abscess occurred in 8 patients. Gas collection in the pancreas was observed in only one patient. In the other patients, pseudocysts had become infected and converted to abscesses. The CT number of 4 infected pseudocysts was less than 15 HU. Thus, it was not possible to distinguish infected from noninfected pseudocysts by CT. The author studied 9 patients with focal inflammatory mass of the pancreas with histologically proved severe fibrosis. All masses were small. Angiography showed occlusion or marked stenosis of the splenic vein in 3 cases. The postcontract CT (after intravenous bolus injection) in 7 cases of focal inflammatory mass demonstrated almost equal enhanced effect of the mass as compared with the adjacent normal pancreatic parenchyma. This finding is considered to be useful in distinguishing inflammatory mass from pancreatic carcinoma. (author)

  15. Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Pawlak, Sebastien; Dechambre, Stephane; Maldague, Baudouin

    2003-01-01

    Our objective was to analyze the peripheral pulmonary arteries using thin-collimation multi-slice spiral CT. Twenty consecutive patients underwent enhanced-spiral multi-slice CT using 1-mm collimation. Two observers analyzed the pulmonary arteries by consensus on a workstation. Each artery was identified on axial and 3D shaded-surface display reconstruction images. Each subsegmental artery was measured at a mediastinal window setting and compared with anatomical classifications. The location and branching of every subsegmental artery was recorded. The number of well-visualized sub-subsegmental arteries at a mediastinal window setting was compared with those visualized at a lung window setting. Of 800 subsegmental arteries, 769 (96%) were correctly visualized and 123 accessory subsegmental arteries were identified using the mediastinal window setting. One thousand ninety-two of 2019 sub-subsegmental arteries (54%) identified using the lung window setting were correctly visualized using the mediastinal window setting. Enhanced multi-slice spiral CT with thin collimation can be used to analyze precisely the subsegmental pulmonary arteries and may identify even more distal pulmonary arteries. (orig.)

  16. CT analysis of pulmonary Wegener's granulomatosis

    International Nuclear Information System (INIS)

    Liao Hualing; Chen Jianbo; Zhong Wenchen; Chen Jingdi

    2010-01-01

    Objective: To study the CT features and to improve the diagnostic accuracy of pulmonary Wegener's granulomatosis. Methods: 11 patients with histopathologically and clinically proven Wegener's granulomatosis were included in the study. Chest radiography was performed in all 11 patients and 8 patients underwent chest CT. Results: Lung abnormalities were noted in 10/11 patients including patchy lung opacities (n=3), multiple nodules (less than 3 cm in diameter, n=4), masses (more than 3cm in diameter, n=3), and cavitations (n=8). Multiple findings were observed in 4 patients. Conclusion: Imaging manifestations of pulmonary Wegener's granulomatosis were variable. Patchy lung opacities, nodules and cavitation were most common. Thin-walled cavity and ring-shaped cavity were characteristic. Pneumonia, abscess, tuberculosis and carcinoma should be included in the differential diagnosis. (authors)

  17. CT findings in skeletal cystic echinococcosis

    Energy Technology Data Exchange (ETDEWEB)

    Tuezuen, M.; Hekimoglu, B. [Social Security Hospital, Ankara (Turkey). Dept. of Radiology

    2002-09-01

    Purpose: To evaluate the CT findings of skeletal cystic echinococcosis. Material and Methods: CT findings of 7 patients with pathologically confirmed skeletal cystic echinococcosis were evaluated. Results: There were 4 men and 3 women, aged 36-75 years. Hydatid cysts were located in the spine (n=2), a rib (n=3), the pelvis and a vertebra (n=1), the pelvis and the left femur (n=1). The size of the lesions varied from 1 cm to 15 cm. CT showed well defined, single or multiple cystic lesions with no contrast enhancement, no calcification, no daughter cysts, and no germinal membrane detachment. The cystic lesion had a honeycomb appearance in 2 cases, there was pathologic fracture in 2 cases, bone expansion in 5 cases, cortical thinning in 6 cases, cortical destruction in 6 cases, bone sclerosis in 1 case, and soft tissue extension in 6 cases. Conclusion: Preoperative differential diagnosis of skeletal cystic lesions should include cystic echinococcosis, especially in endemic areas, since this diagnosis may easily be missed unless kept in mind.

  18. Widely scattered CT lesions in the midbrain and the pons in a case of neuro-Behcet's syndrome

    International Nuclear Information System (INIS)

    Kuroiwa, Yoshiyuki; Tohgi, Hideo; Kanayama, Hiroumi; Fujimori, Masaki; Aoki, Hidehiko

    1985-01-01

    We report on a 30-year-old man with neuro-Behcet's disease. His main neurologic symptoms and signs included headache, alternating hemiparesis, dysarthria, and truncal ataxia. Lumbar puncture demonstrated an elevated pressure, pleocytosis, and an increased protein concentration. Intravenous betamethasone produced a rapid and sustained improvement, without recurrence for two years. Widely scattered foci of small, low-density lesions were disclosed in the midbrain and the pons on a cranial CT scan with 2.5 mm thin-cut slices to enable us to focus on the brainstem. Such CT lesions are consistent with the neuropathological features of this illness, which shows a tendency for brainstem lesions to predominate; these lesions probably represent necrotic areas secondary to vasculitis. Brainstem CT studies with thin-cut slices may be an important diagnostic aid in patients suspected of having neuro-Behcet's disease. (author)

  19. Vibrational mode and sound radiation of electrostatic speakers using circular and annular diaphragms

    Science.gov (United States)

    Huang, Yu-Hsi; Chiang, Hsin-Yuan

    2016-06-01

    This study modeled two diaphragms comprising a pair of indium tin oxide (ITO) transparent plates sandwiching a vibrating diaphragm to create circular (30 mm radius) and annular (30 mm outer and 3 mm inner radius) push-pull electrostatic speakers. We then measured the displacement amplitudes and mode shapes produced by the devices. Vibration characteristics were used to predict sound pressure levels (SPLs) using the lumped parameter method (LPM) and distributed parameter method (DPM). The two measurement results obtained using a laser system were compared to the SPLs obtained using traditional acoustic measurement (AM) from 20 Hz to 20 kHz in order to verify our predictions. When using LPM and DPM, the SPL prediction results in the first three symmetric modes were in good agreement with the AM results. Under the assumption of linear operations, the DPM and amplitude-fluctuation electronic speckle pattern interferometry (ESPI) techniques proved effective in determining the visualization of mode shape (0,1)-(0,3). The use of ITO plates is a practical technique for the prediction of SPL, as well as measurement of mode shapes. The four evaluation methods, i.e. LPM, DPM, ESPI and AM, present a high degree of consistency with regard to vibrational mode and sound radiation characteristics.

  20. An electrostatic scanning micromirror with diaphragm mirror plate and diamond-shaped reinforcement frame

    Science.gov (United States)

    Ji, Chang-Hyeon; Choi, Moongoo; Kim, Sang-Cheon; Lee, See-Hyung; Kim, Seong-Hyok; Yee, Youngjoo; Bu, Jong-Uk

    2006-05-01

    We present the design, fabrication and measurement results of a comb-driven electrostatic scanning micromirror. Instead of a conventional micromirror having uniform thickness across the entire reflective surface, a diaphragm mirror plate supported by an array of diamond-shaped frame structures is fabricated monolithically. The fabrication process is a simple sequence of silicon deep etch processes on both sides of the silicon-on-insulator (SOI) substrate without the substrate bonding process. The micromirror is fabricated on the device layer of the substrate. The mirror plate undergoes a rotational motion by an electrostatic force between the movable comb electrodes connected to the micromirror and stationary comb electrode formed on the handle wafer. A scanning micromirror with a 10 µm thick diaphragm mirror plate, having a planar dimension of 1.5 × 1.5 mm2, supported by an array of 110 µm thick rhombic support frames, was fabricated and tested. A mechanical deflection angle of 8.5° at a resonance frequency of 19.55 kHz and a pressure of 7 mTorr was obtained. A prototype of the raster scanning laser projection display system was developed using the fabricated micromirror as the horizontal scanner and a galvanomirror as the vertical scanner, respectively.

  1. Intra-myocardial Bullet causing heart block in a patient with multiple ...

    African Journals Online (AJOL)

    consolidation and bullet lodged above the diaphragm. The chest radiograph showed bullet lodged above the diaphragm. ARDS resolved markedly over the following. 7 days. However, there were persistent bronchial breath sounds in the left lower lung with purulent secretions and collapse with consolidation. CT scan of the ...

  2. Development of CT and 3D-CT Using Flat Panel Detector Based Real-Time Digital Radiography System

    International Nuclear Information System (INIS)

    Ravindran, V. R.; Sreelakshmi, C.; Vibin

    2008-01-01

    The application of Digital Radiography in the Nondestructive Evaluation (NDE) of space vehicle components is a recent development in India. A Real-time DR system based on amorphous silicon Flat Panel Detector has been developed for the NDE of solid rocket motors at Rocket Propellant Plant of VSSC in a few years back. The technique has been successfully established for the nondestructive evaluation of solid rocket motors. The DR images recorded for a few solid rocket specimens are presented in the paper. The Real-time DR system is capable of generating sufficient digital X-ray image data with object rotation for the CT image reconstruction. In this paper the indigenous development of CT imaging based on the Realtime DR system for solid rocket motor is presented. Studies are also carried out to generate 3D-CT image from a set of adjacent CT images of the rocket motor. The capability of revealing the spatial location and characterisation of defect is demonstrated by the CT and 3D-CT images generated.

  3. A technique for the quantification of the 3D connectivity of thin articulations in bony sutures.

    Science.gov (United States)

    Maloul, Asmaa; Fialkov, Jeffrey; Hojjat, Seyed-Parsa; Whyne, Cari M

    2010-04-19

    The anatomy and development of cranial and facial sutures have been studied in detail using histological sections, 2D radiographs and more recently CT imaging. However, little attention has been paid to evaluating and quantifying the connectivity of these thin cortical bone articulations. More recent technological advances such as micro-CT imaging has the potential to be used to provide quantitative measurements of 3D connectivity in bony articulations. This study presents a new technique for quantifying the connectivity of bony projections inside cranial and facial sutures using a combination of skeletonization, thinning algorithms and 3D intensity mapping. The technique is demonstrated in five sutures through semi-automated analysis and image processing of microCT scans. In the sagittal, coronal and frontozygomatic sutures an average bone connectivity of 6.6-11.6% was found with multiple bony projections providing an interlocking structure between adjacent bones. Much higher bone connectivity was present in the zygomaticotemporal and zygomaticomaxillary sutures (22.7-37.4%) with few bony projections. This method combining microCT scanning and image processing techniques was successfully used to quantify the connectivity of thin bone articulations and allowed detailed assessment of sutural fusion in 3D. The wider application of this technique may allow quantification of connectivity in other structures, in particular fracture healing of long bones. Copyright 2009 Elsevier Ltd. All rights reserved.

  4. CT imaging of hepatic veno-occlusive disease (an analysis 14 cases)

    International Nuclear Information System (INIS)

    Zhang Guohua; Kong Azhao; Fang Junwei; Chen Yuejing; Zheng Weiliang; Dong Danjun; Zhang Shizheng

    2006-01-01

    Objective: To probe imaging characteristics of the hepatic veno-occlusive disease (VOD) based on clinical features and abdomen CT findings. Methods: Fourteen patients including 6 male and 8 female aged from 41 to 73 years were enrolled in this study. They all had previous trauma history and notoginseng was given as herbal remedy. Dynamic enhanced CT and color Dopplor ultrasound examinations were routinely used. Two of them received venous angiography and four cases were pathologically proved as VOD after CT guided needle biopsy. Results: Hepatic swelling and ascites were found on plain CT scan. Diffuse patchy areas without enhancement indicative of poorly hepatic perfusion were found. Hepatic veins were compressed and became thin, and inferior vena cava was flat and narrow without distal dilation or collateral circulation. No obstruction of hepatic veins and inferior vena cava was found on ultrasound and venography. Conclusion: Dynamic enhanced CT is highly valuable for early assessing VOD and imaging features of venous hepatic congestion found on CT was strongly suggestive of VOD if there's previous history of treatment of gynura segetum. (authors)

  5. CT-Urography; Urografia CT

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, Ludovico; Grotto, Maurizio [Trieste Univ., Trieste (Italy). Dipartimento di scienze cliniche, morfologiche e tecnologiche, UCO di radiologia; Morra, Aldo [CRO, Aviano (Italy). Reparto di radiologia

    2005-09-15

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography. [Italian] Gli Autori presentano una panoramica sulla Urografia TC (Uro TC). L'avvento della TC multistrato e l'evoluzione delle tecniche di elaborazione consentono di ottenere dei quadri urografici ottimali comparativi con quelli convenzionali. Vengono ricordate le varie tecniche di acquisizione e i protocolli usati dai vari Autori. La dose effettiva di radiazioni ha rappresentato uno dei fattori condizionanti per cui oggi prevale l'orientamento di ridurre il numero di scansioni, considerando dopo la scansione senza mezzo di contrasto un'unica scansione contrasto grafica comprendente sia la fase nefrografica che quella urografica. Con l'uso della TC multistrato la qualita dell'urogramma migliora con l'aumento del numero degli strati. Vengono descritte le varie tecniche di elaborazione, la

  6. Tomography high Resolution CT findings of nontuberculous mycobacterial pulmonary disease: Comparison between the first treatment and the re treatment group

    Energy Technology Data Exchange (ETDEWEB)

    Gwak, Soon Hyuk; Cho, Bum Sang; Jeon, Min Hee; Kim, Eun Young; Kang, Min Ho; Yi, Kyung Sik; Lee, Seung Young; Kim, Sung Jin; Lee, Ki Man [Chungbuk National Univ., Cheongju, (Korea, Republic of)

    2012-06-15

    To analyze and compare the thin section CT findings of first and re treatment nontuberculous mycobacterial (NTM) pulmonary disease. Between January 2005 and April 2010, 121 patients with positive sputum culture for NTM were recruited. We included only 32 patients underwent high resolution chest CT and were confirmed by American Thoracic Society criteria NTM pulmonary infection (first treatment 15, re treatment 17 patients). CT images of 32 patients were reviewed retrospectively. We evaluated the frequency and laterality of the followings; nodule, increased density, bronchial change, parenchymal change. The significantly frequent CT findings of the re treatment NTM group were well defined nodules (retreatment 82.4%, first treatment 33.3%, p = 0.00), consolidations (retreatment 88.2%, first treatment 53.3%, p = 0.03), bronchial changes (bronchiectasis; retreatment 100%, first treatment 66.6%, p = 0.01, bronchial narrowing; retreatment 23.5%, first treatment 0%, p = 0.04 and mucoid impaction; retreatment-58.8%, first treatment-20.0%, p = 0.03) and atelectasis with bronchiectasis (retreatment-88.2%, first treatment 26.7%, p = 0.00). However, most of the evaluated thin section CT findings, such as centrilobular and ill defined nodules, lobular, segmental and subpleural consolidations, ground glass attenuation, bronchial wall thickening, cavities, pleural lesions, fibrotic band, emphysema and laterality of lesions, have not shown significant differences between first treatment and the re treatment group. Thin section CT findings of well defined nodules, consolidations, bronchial changes (bronchiectasis, bronchial narrowing and mucoid impaction) and atelectasis with bronchiectasis are highly suggestive of re treatment NTM pulmonary disease.

  7. Paleoradiology: advanced CT in the evaluation of nine Egyptian mummies.

    Science.gov (United States)

    Hoffman, Heidi; Torres, William E; Ernst, Randy D

    2002-01-01

    Axial thin-collimation state-of-the-art spiral computed tomography (CT) was combined with sagittal and coronal reformatting, three-dimensional (3D) reconstruction, and virtual "fly-through" techniques to nondestructively study nine Egyptian mummies. These techniques provided important paleopathologic and historical information about mummification techniques, depicted anatomy in the most informative imaging plane, illustrated the soft-tissue preservation and physical appearance of mummies in superb detail, and generated an intriguing virtual tour through hollow mummified remains without harming the specimens themselves. Images generated with these methods can help archaeologists and Egyptologists understand these fascinating members of mankind and can serve as adjunct visual aids for laypersons who are interested in mummies. CT has emerged as the imaging modality of choice for the examination of Egyptian mummies due to its noninvasive cross-sectional nature and inherently superior contrast and spatial resolution. As multi-detector row CT and postprocessing tools evolve, the capabilities and applications of CT will continue to proliferate, attesting to the expanded versatility and utility of CT as a noninvasive research tool in the multidisciplinary study of Egyptian mummies. Copyright RSNA, 2002

  8. Rib fracture after stereotactic radiotherapy on follow-up thin-section computed tomography in 177 primary lung cancer patients

    Directory of Open Access Journals (Sweden)

    Saito Ryo

    2011-10-01

    Full Text Available Abstract Background Chest wall injury after stereotactic radiotherapy (SRT for primary lung cancer has recently been reported. However, its detailed imaging findings are not clarified. So this study aimed to fully characterize the findings on computed tomography (CT, appearance time and frequency of chest wall injury after stereotactic radiotherapy (SRT for primary lung cancer Materials and methods A total of 177 patients who had undergone SRT were prospectively evaluated for periodical follow-up thin-section CT with special attention to chest wall injury. The time at which CT findings of chest wall injury appeared was assessed. Related clinical symptoms were also evaluated. Results Rib fracture was identified on follow-up CT in 41 patients (23.2%. Rib fractures appeared at a mean of 21.2 months after the completion of SRT (range, 4 -58 months. Chest wall edema, thinning of the cortex and osteosclerosis were findings frequently associated with, and tending to precede rib fractures. No patients with rib fracture showed tumors > 16 mm from the adjacent chest wall. Chest wall pain was seen in 18 of 177 patients (10.2%, of whom 14 patients developed rib fracture. No patients complained of Grade 3 or more symptoms. Conclusion Rib fracture is frequently seen after SRT for lung cancer on CT, and is often associated with chest wall edema, thinning of the cortex and osteosclerosis. However, related chest wall pain is less frequent and is generally mild if present.

  9. Rib fracture after stereotactic radiotherapy on follow-up thin-section computed tomography in 177 primary lung cancer patients

    Science.gov (United States)

    2011-01-01

    Background Chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer has recently been reported. However, its detailed imaging findings are not clarified. So this study aimed to fully characterize the findings on computed tomography (CT), appearance time and frequency of chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer Materials and methods A total of 177 patients who had undergone SRT were prospectively evaluated for periodical follow-up thin-section CT with special attention to chest wall injury. The time at which CT findings of chest wall injury appeared was assessed. Related clinical symptoms were also evaluated. Results Rib fracture was identified on follow-up CT in 41 patients (23.2%). Rib fractures appeared at a mean of 21.2 months after the completion of SRT (range, 4 -58 months). Chest wall edema, thinning of the cortex and osteosclerosis were findings frequently associated with, and tending to precede rib fractures. No patients with rib fracture showed tumors > 16 mm from the adjacent chest wall. Chest wall pain was seen in 18 of 177 patients (10.2%), of whom 14 patients developed rib fracture. No patients complained of Grade 3 or more symptoms. Conclusion Rib fracture is frequently seen after SRT for lung cancer on CT, and is often associated with chest wall edema, thinning of the cortex and osteosclerosis. However, related chest wall pain is less frequent and is generally mild if present. PMID:21995807

  10. Cystic thymic diseases: CT manifestations

    International Nuclear Information System (INIS)

    Song, Soon Young; Choi, Yo Won; Jeon, Eui Yong; Jeon, Seok Chol; Seo, Heung Suk; Hahm, Chang Kok

    1995-01-01

    To describe CT findings and differential points of cystic thymic lesions. We evaluated retrospectively total 19 masses with well marginated cystic lesions at thymic area on CT scans. They were 10 teratomas, 3 congenital thymic cysts, 2 multilocular thymic cysts(associated with thymoma and myasthenia gravis in each), 2 cysts Assciated with thymic Hodgkin's lymphomas an ectopic parathyroid cyst, and an infected thymic cyst. The radiological abnormalities evaluated were thickness of the wall, presence or abscene of septa, mural nodule, solid component, calcification and fat component. All three cases of congenital thymic cysts and an ectopic parathyroid cyst appeared as thin-walled unilocular cyst with homogeneous internal density and without identifiable solid component. In multilocular thymic cyst, there were thick wall and solid components(n =2), thick internal septa and calcifications(n = 1). The cysts of teratomas manifested thick walls(n = 9), internal septa(n = 4), calcifications(n = 6), fat components(n = 4), and solid components(n = 4). Cysts in Hodgkin's diseases appeared as multilocular or unilocular and had thick wall and septa without calcification. Infected thymic cyst presented with multilocular cystic mass with identifiable wall and septa, calcification, and solid components. The thymic diseases with cystic lesion include teratomas, congenital thymic cysts, multilocular thymic cysts, parathyroid cyst, and Hodgkin's disease. Congenital thymic cyst and ectopic parathyroid cyst are thin-walled unilocular cystic lesions. Cystic lesions associated with teratoma, Hodgkin's disease, and multilocular thymic cyst are thick-walled cystic lesions with or without solid component

  11. Recruitment of rat diaphragm motor units across motor behaviors with different levels of diaphragm activation.

    Science.gov (United States)

    Seven, Yasin B; Mantilla, Carlos B; Sieck, Gary C

    2014-12-01

    Phrenic motor neurons are recruited across a range of motor behaviors to generate varying levels of diaphragm muscle (DIAm) force. We hypothesized that DIAm motor units are recruited in a fixed order across a range of motor behaviors of varying force levels, consistent with the Henneman Size Principle. Single motor unit action potentials and compound DIAm EMG activities were recorded in anesthetized, neurally intact rats across different motor behaviors, i.e., eupnea, hypoxia-hypercapnia (10% O2 and 5% CO2), deep breaths, sustained airway occlusion, and sneezing. Central drive [estimated by root-mean-squared (RMS) EMG value 75 ms after the onset of EMG activity (RMS75)], recruitment delay, and onset discharge frequencies were similar during eupnea and hypoxia-hypercapnia. Compared with eupnea, central drive increased (∼25%) during deep breaths, and motor units were recruited ∼12 ms earlier (P motor units were recruited ∼30 ms earlier (P motor unit onset discharge frequencies were significantly higher (P Recruitment order of motor unit pairs observed during eupnea was maintained for 98%, 87%, and 84% of the same pairs recorded during hypoxia-hypercapnia, deep breaths, and airway occlusion, respectively. Reversals in motor unit recruitment order were observed primarily if motor unit pairs were recruited motor unit recruitment order being determined primarily by the intrinsic size-dependent electrophysiological properties of phrenic motor neurons. Copyright © 2014 the American Physiological Society.

  12. The value of X-ray CT in orbital fractures

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Myung Hee; Lee, Jae Mun; Kim, Choon Yul; Bahk, Yong Whee [Catholic Medical College, Seoul (Korea, Republic of)

    1986-08-15

    On the pulse from the trauma transiting to posterior side of the orbit, orbital fractures are occurred through the weak point of the orbital wall. Invagination of soft tissue or entrapment of muscles may be associated with orbital fracture. In condition of inaccurate diagnosis, appropriate surgical repairment is impossible and complication such as diplopia or enophthalmia are developed. CT scan is diagnostic procedure which demonstrates accurately the site and state of orbital fracture, and its associated findings. The authors has been studied in 21 orbital CT scan to evaluate the relative value of plain X rays and CT scans in the diagnosis of orbital fractures during the period from January 1982 to September 1985. The conclusions were as follows: 1. Diagnostic rate was 100% by CT, 40% by initial and 80% by retrospective interpretation of conventional X-ray films. 2. Low X-ray diagnostic rate of medical wall fractures (26.7%) was due to thinness of the bone. 3. Medial wall fractures were associated with floor fractures in 46%. 4. Orbital soft tissue injuries and abnormalities of PNS were precisely evaluated by CT scan.

  13. CT evaluation of gastric cancer. Depth of tumor invasion and pancreas invasion

    International Nuclear Information System (INIS)

    Banba, Yoshihisa; Kanazawa, Tadayoshi; Seto, Hikaru

    1998-01-01

    To compare the internal structure of tumor and the contiguous organ configuration on computed tomography (CT) with the depth of tumor invasion on the pathological specimen. Sixty-four gastric cancers depicted on incremental dynamic CT were classified according to the internal structure of the tumor, and correlated with the depth of tumor invasion. In addition, the cancers were classified according to the contiguous pancreatic configuration, and correlated with the degree of pancreatic invasion. Eleven tumors with thickened gastric wall consisting of both a thick inner layer of high attenuation and a thin outer layer of low attenuation (two-layered tumor with a thin outer layer) did not invade the serosa: mucosa (n=5) and submucosa (n=6). Of 59 gastric cancers with a regular margin to the contiguous pancreas, pancreatic invasion was absent in 58 and present in one. Pancreatic invasion was present in all of five gastric cancers with an irregular margin. Our results indicate that two-layered gastric tumors with a thin outer layer never invade the serosa. Furthermore, pancreatic invasion is predicted only when the margin of the contiguous pancreas is irregular. (author)

  14. Partial recovery of respiratory function and diaphragm reinnervation following unilateral vagus nerve to phrenic nerve anastomosis in rabbits.

    Directory of Open Access Journals (Sweden)

    Junxiang Wen

    Full Text Available Respiratory dysfunction is the leading cause of mortality following upper cervical spinal cord injury (SCI. Reinnervation of the paralyzed diaphragm via an anastomosis between phrenic nerve and a donor nerve is a potential strategy to mitigate ventilatory deficits. In this study, anastomosis of vagus nerve (VN to phrenic nerve (PN in rabbits was performed to assess the potential capacity of the VN to compensate for lost PN inputs. At first, we compared spontaneous discharge pattern, nerve thickness and number of motor fibers between these nerves. The PN exhibited a highly rhythmic discharge while the VN exhibited a variable frequency discharge pattern. The rabbit VN had fewer motor axons (105.3±12.1 vs. 268.1±15.4. Nerve conduction and respiratory function were measured 20 weeks after left PN transection with or without left VN-PN anastomosis. Compared to rabbits subjected to unilateral phrenicotomy without VN-PN anastomosis, diaphragm muscle action potential (AP amplitude was improved by 292%, distal latency by 695%, peak inspiratory flow (PIF by 22.6%, peak expiratory flow (PRF by 36.4%, and tidal volume by 21.8% in the anastomosis group. However, PIF recovery was only 28.0%, PEF 28.2%, and tidal volume 31.2% of Control. Our results suggested that VN-PN anastomosis is a promising therapeutic strategy for partial restoration of diaphragm reinnervation, but further modification and improvements are necessary to realize the full potential of this technique.

  15. Characteristic features of computed tomography (CT) in hepatic schistosomiasis japonica

    Energy Technology Data Exchange (ETDEWEB)

    Sakemi, Taisuke; Sakai, Terufumi; Majima, Yasuo [Kurume Univ., Fukuoka (Japan). School of Medicine

    1984-06-01

    Characteristic finding of CT in the liver of hepatic schistosomiasis japonica were compared with histological changes. The study was made on 7 cases with schistosomatic liver cirrhosis (SLC) and 7 SLC cases with hepatocellular carcinoma (HCC). Characteristic CT findings were high density funicular patterns showing turtle shell appearance (4 cases), high density spotty patterns (3 cases) and both mixed patterns (7 cases). These patterns were not changed by contrast medium study. Funicular and mixed patterns were observed in both lobes of the liver, however, spotty patterns were seen only in the right lobe. It was difficult to distinguish liver tissue surrounded by funicular patterns from HCC lesion. Histopathological study of autopsied livers and CT scanning of thin cut livers revealed that high density funicular patterns represent deposits of calcified schistosomal ova in the fibrous septa.

  16. Development of Optophone with No Diaphragm and Application to Sound Measurement in Jet Flow

    Directory of Open Access Journals (Sweden)

    Yoshito Sonoda

    2012-01-01

    Full Text Available The optophone with no diaphragm, which can detect sound waves without disturbing flow of air and sound field, is presented as a novel sound measurement technique and the present status of development is reviewed in this paper. The method is principally based on the Fourier optics and the sound signal is obtained by detecting ultrasmall diffraction light generated from phase modulation by sounds. The principle and theory, which have been originally developed as a plasma diagnostic technique to measure electron density fluctuations in the nuclear fusion research, are briefly introduced. Based on the theoretical analysis, property and merits as a wave-optical sound detection are presented, and the fundamental experiments and results obtained so far are reviewed. It is shown that sounds from about 100 Hz to 100 kHz can be simultaneously detected by a visible laser beam, and the method is very useful to sound measurement in aeroacoustics. Finally, present main problems of the optophone for practical uses in sound and/or noise measurements and the image of technology expected in the future are shortly shown.

  17. Textures in spinel peridotite mantle xenoliths using micro-CT scanning: Examples from Canary Islands and France

    Science.gov (United States)

    Bhanot, K. K.; Downes, H.; Petrone, C. M.; Humphreys-Williams, E.

    2017-04-01

    Spinel pyroxene-clusters, which are intergrowths of spinel, orthopyroxene and clinopyroxene in mantle xenoliths, have been investigated through the use of micro-CT (μ-CT) in this study. Samples have been studied from two different tectonic settings: (1) the northern Massif Central, France, an uplifted and rifted plateau on continental lithosphere and (2) Lanzarote in the Canary Islands, an intraplate volcanic island on old oceanic lithosphere. μ-CT analysis of samples from both locations has revealed a range of spinel textures from small Lanzarote are regions that have experienced significant lithospheric thinning. This process provides a mechanism where the sub-solidus reaction of olivine + garnet = orthopyroxene + clinopyroxene + spinel is satisfied by providing a pathway from garnet peridotite to spinel peridotite. We predict that such textures would only occur in the mantle beneath regions that show evidence of thinning of the lithospheric mantle. Metasomatic reactions are seen around spinel-pyroxene clusters in some Lanzarote xenoliths, so metasomatism post-dated cluster formation.

  18. High-resolution CT in eosinophilic granuloma (histiocytosis X) of the lung

    International Nuclear Information System (INIS)

    Godwin, J.D.; Buschman, D.L.; Moore, A.D.A.; Muller, N.L.; Naidich, D.P.; Carvalho, C.R.R.; Takasugi, J.E.; Schmidt, R.A.

    1988-01-01

    Eosinophilic granuloma of the lung is fascinating but poorly understood. Computed tomographic (CT) scans in 18 cases (11 high resolution) showed a variety of striking patterns: cysts up to 4 cm with thin or indiscernible walls, ranging from a few lesions to confluent honeycombing; retriculonodular infiltrate; and nodules 2 mm-2cm, sometimes cavitated. CT showed that the ill-defined lucencies barely visible on radiographs are indeed cysts, rather than preserved normal lung surrounded by infiltrate. High-resolution CT showed that some of the early, small nodules were concentrated along terminal bronchioles within the secondary lobules. The differential diagnosis includes sarcoidosis and idiopathic fibrosis, but the prominent cystic abnormality and the lack of peripheral concentration help to distinguish eosinophilic granuloma

  19. Effect of historical earthquakes on pre-stressed anchor tie back diaphragm wall and on near-by building

    Directory of Open Access Journals (Sweden)

    Kamal Mohamed Hafez Ismail Ibrahim

    2013-04-01

    Full Text Available Pre-stressed tie back anchored diaphragm walls are considered one of the safest lateral supports which help in overall stability when there is a significant difference in land level between back and front of these walls. Permanent lateral supports to these walls are frequently represented by supporting it laterally with foundation and floor slabs of the building. In this paper a special study of one raw anchor diaphragm wall subjected to different earthquake dynamic loads will be presented. The wall retains an excavation of 9.5 m and supports laterally a near-by 5 floor building. Five historical strong motions with different fundamental frequencies are subjected on the wall. The wall displacement, straining actions, anchor extreme force and the influence of variation of anchor stiffness are calculated using a dynamic Plaxis finite element program. The soil is considered as elasto-plastic material and represented using Mohr–Coulomb criteria, the wall and the anchor are considered to behave elastically. Prescribed displacement at the lower bottom boundary represents the earthquake motion. Far left and right absorbent boundaries are assumed to prevent dynamic wave reflection. Four static phases representing construction procedure and one dynamic loading phase are considered. It is found that the straining actions of different historical earthquakes match in shape with each other, the only change is in the amplitude which is affected by earthquake fundamental frequency and its intensity. The maximum dynamic lateral displacement of the wall is at its free top. The near-by building shows a differential settlement towards the wall which causes a change in the sign and amplitude of the straining actions. Increasing the stiffness of anchor was also studied and it was found that it reduces too much the maximum dynamic top wall lateral displacement.

  20. CT-docking patient stretcher

    International Nuclear Information System (INIS)

    Mirvis, S.E.; Owens, E.; Maslyn, J.; Rizutto, M.

    1990-01-01

    This paper assesses the use of a patient stretcher that directly docks to a CT scanner for acutely injured and/or critically ill patients. The stretcher permits performance of radiography and acts as a platform for critical care monitoring and patient support devices. During a 1-year period, the prototype CT-docking stretcher was used for 35 patients sustaining acute trauma and 25 patients from critical care units. Observations were elicited from physicians, nurses and technologists concerning the advantages or disadvantages of the docking stretcher. Advantages of the CT-docking stretcher included time saved in moving patients to the CT table from the admitting/emergency ward, transfer of critically ill patients onto the stretcher in the controlled environment of the intensive care unit rather than the CT suite, increasing CT throughput by direct docking of the patient stretcher to the CT scanner rather than manual transfer of complex support and monitoring devices with the patient, decreased risk associated with physical movement of patients with potentially unstable spinal injuries or unstable physiologic status, and decrease in potential for injury to medical personnel performing patient transfer

  1. Borrmann type IV adenocarcinoma versus gastric lymphoma : spiral CT evaluation

    International Nuclear Information System (INIS)

    Seo, Bo Kyoung; Kim, Yun Hwan; Shin, Kue Hee; Hong, Suk Joo; Kim, Hong Weon; Park, Cheol Min; Chung, Kyoo Byung; Cho, Hyun Deuk

    1999-01-01

    To distinguish the spiral CT findings of Borrmann type IV adenocarcinoma from those of gastric lymphoma with diffuse gastric wall thickening. We retrospectively reviewed the spiral CT scans of 30 patients with Borrmann type IV adenocarcinoma and nine with gastric lymphoma with diffuse gastric wall thickening. In all patients the respective condition was pathologically confirmed by gastrectomy. CT scanning was performed after peroral administration of 500-700ml of water. A total of 120-140 ml bolus of nonionic contrast material was administered intravenously at a flow rate of 3 ml/sec and two-phase images were obtained at 35-45 sec(early phase) and 180 sec(delayed phase) after the start of bolus injection. Spiral CT was performed with 10mm collimation, 10mm/sec table feed and 10mm reconstruction. We evaluated the degree and homogeneity of enhancement of thickened entire gastric wall, and the enhancement pattern of gastric inner layer, as seen on early-phase CT scans. On early and delayed views, the thickness of gastric wall and the presence of perigastric fat infiltration were determined. The enhancement patterns of gastric inner layer were classified as either continuous or discontinuous thick enhancement, thin enhancement, or nonenhancement. The thickness of gastric wall was 1.2-3.5cm(mean 2.2cm) in cases of adenocarcinoma and 1.2-7.6cm(mean 4cm) in lymphoma. Perigastric fat infiltration was seen in 24 patients with adenocarcinoma(80%) and four with lymphoma(44%). In those with adenocarcinoma, the degree of enhancement of entire gastric wall was hyperdense in fifteen patients(50%) and isointense in eleven (37%). Seven patients with lymphoma(78%)showed hypodensity. In those with adenocarcinoma, continuous thick enhancement of gastric inner layer was seen in 18 patients(60%) and discontinuous thick enhancement in nine(30%). In lymphoma cases, no thick enhancement was observed. Thin enhancement of gastric inner layer was demonstrated in three patients with

  2. A segmentation and point-matching enhanced efficient deformable image registration method for dose accumulation between HDR CT images

    International Nuclear Information System (INIS)

    Zhen, Xin; Chen, Haibin; Zhou, Linghong; Yan, Hao; Jiang, Steve; Jia, Xun; Gu, Xuejun; Mell, Loren K; Yashar, Catheryn M; Cervino, Laura

    2015-01-01

    Deformable image registration (DIR) of fractional high-dose-rate (HDR) CT images is challenging due to the presence of applicators in the brachytherapy image. Point-to-point correspondence fails because of the undesired deformation vector fields (DVF) propagated from the applicator region (AR) to the surrounding tissues, which can potentially introduce significant DIR errors in dose mapping. This paper proposes a novel segmentation and point-matching enhanced efficient DIR (named SPEED) scheme to facilitate dose accumulation among HDR treatment fractions. In SPEED, a semi-automatic seed point generation approach is developed to obtain the incremented fore/background point sets to feed the random walks algorithm, which is used to segment and remove the AR, leaving empty AR cavities in the HDR CT images. A feature-based ‘thin-plate-spline robust point matching’ algorithm is then employed for AR cavity surface points matching. With the resulting mapping, a DVF defining on each voxel is estimated by B-spline approximation, which serves as the initial DVF for the subsequent Demons-based DIR between the AR-free HDR CT images. The calculated DVF via Demons combined with the initial one serve as the final DVF to map doses between HDR fractions. The segmentation and registration accuracy are quantitatively assessed by nine clinical HDR cases from three gynecological cancer patients. The quantitative analysis and visual inspection of the DIR results indicate that SPEED can suppress the impact of applicator on DIR, and accurately register HDR CT images as well as deform and add interfractional HDR doses. (paper)

  3. Generalized free-space diffuse photon transport model based on the influence analysis of a camera lens diaphragm.

    Science.gov (United States)

    Chen, Xueli; Gao, Xinbo; Qu, Xiaochao; Chen, Duofang; Ma, Xiaopeng; Liang, Jimin; Tian, Jie

    2010-10-10

    The camera lens diaphragm is an important component in a noncontact optical imaging system and has a crucial influence on the images registered on the CCD camera. However, this influence has not been taken into account in the existing free-space photon transport models. To model the photon transport process more accurately, a generalized free-space photon transport model is proposed. It combines Lambertian source theory with analysis of the influence of the camera lens diaphragm to simulate photon transport process in free space. In addition, the radiance theorem is also adopted to establish the energy relationship between the virtual detector and the CCD camera. The accuracy and feasibility of the proposed model is validated with a Monte-Carlo-based free-space photon transport model and physical phantom experiment. A comparison study with our previous hybrid radiosity-radiance theorem based model demonstrates the improvement performance and potential of the proposed model for simulating photon transport process in free space.

  4. Tracheomalacia in adults with cystic fibrosis: determination of prevalence and severity with dynamic cine CT.

    LENUS (Irish Health Repository)

    McDermott, Shaunagh

    2012-02-01

    PURPOSE: To determine the prevalence and severity of tracheomalacia in adults with cystic fibrosis (CF) by using dynamic cine multidetector computed tomography (CT) and to correlate these findings with pulmonary function test (PFT) results and the severity of parenchymal lung disease. MATERIALS AND METHODS: In this institutional review board-approved HIPAA-compliant study, 40 patients with CF (22 men, 18 women; mean age, 28 years +\\/- 8 [standard deviation]; age range, 18-54 years) prospectively underwent PFTs, standard thin-section CT, and two dynamic cine multidetector CT acquisitions. Ten control subjects underwent dynamic cine multidetector CT. After standard thin-section CT was completed, dynamic cine multidetector CT was performed during a forced expiratory maneuver and during coughing. Dynamic cine multidetector CT images in nine patients were excluded. Maximal inspiratory, dynamic expiratory, and end-expiratory tracheal luminal areas were compared (Student t test) and correlated (Spearman rank) with PFT results and severity of parenchymal lung disease. RESULTS: Mean predicted forced expiratory volume in 1 second (FEV(1)) was 70.6% +\\/- 20.7, and mean Bhalla CT score was 41.8% +\\/- 13.6. In patients with CF, dynamic cine mean tracheal cross-sectional area reduction was 51.7% +\\/- 18.4 (range, 9%-89%) for forced expiratory maneuvers and 68.8% +\\/- 11.7 (range, 18%-88%) for coughing (P = .001). Tracheomalacia was demonstrated in 24 (69%) patients and no control subjects during forced expiratory maneuvers (P = .001) and in 10 (29%) patients and one (10%) control subject during coughing. For end-expiration images, mean tracheal luminal reduction was 16.1% +\\/- 14.0% (range, 0.0%-53.0%), with one patient demonstrating tracheal luminal reduction of more than 50%. There was no correlation between tracheal cross-sectional luminal reduction and either predicted FEV(1) or CT Bhalla score. CONCLUSION: Tracheomalacia depicted at dynamic cine multidetector CT is a

  5. Optical-CT scanning of polymer gels

    Energy Technology Data Exchange (ETDEWEB)

    Oldham, M [Radiation Oncology Physics, Duke University Medical Center, Duke University, NC (United States)

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data.

  6. Optical-CT scanning of polymer gels

    International Nuclear Information System (INIS)

    Oldham, M

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data

  7. Improved CT imaging in diagnosis of ankylosing spondylitis

    International Nuclear Information System (INIS)

    Mai Yuanfeng; Sun Haixing; Ling Jian; Kuang Jianyi; Pan Ximin

    2006-01-01

    Objective: To evaluate the improved CT imaging of sacroiliac joint in diagnosis of ankylosing spondylitis (AS). Methods: 22 patients, diagnosed as AS by clinical and radiography, undertook both conventional and improved CT imaging. All images were comparatively studied. Results: With conventional CT imaging, in the 44 joints of 22 cases, unremarkable images were obtained in 3 cases; early stage AS was found in 15 joints of 9 cases; AS in progressive stage was revealed in 8 cases/16 joints, stabled AS was presented in 2 cases/4 joints. There were 23 joints in 12 cases diagnosed as early term by improved imaging, progressive staged AS was shown in 8 cases/16 joints as, stable AS was demonstrated in 2 cases/4 joints. Conclusion: The improved imaging is sensitive in the diagnosis of early staged AS, for the application of thin slice scan, which helps to reduce partial volume effect. Scanning along the longitudinal axis of the sacroiliac joint extends the observation of erosion of the joint surface. For progressive or stable staged AS, the alterations of bone and joint space are prominent, improved CT imaging is not superior to the conventional. (authors)

  8. CT quantification of central airway in tracheobronchomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Im, Won Hyeong; Jin, Gong Yong; Han, Young Min; Kim, Eun Young [Dept. of Radiology, Chonbuk National University Hospital, Jeonju (Korea, Republic of)

    2016-05-15

    To know which factors help to diagnose tracheobronchomalacia (TBM) using CT quantification of central airway. From April 2013 to July 2014, 19 patients (68.0 ± 15.0 years; 6 male, 13 female) were diagnosed as TBM on CT. As case-matching, 38 normal subjects (65.5 ± 21.5 years; 6 male, 13 female) were selected. All 57 subjects underwent CT with end-inspiration and end-expiration. Airway parameters of trachea and both main bronchus were assessed using software (VIDA diagnostic). Airway parameters of TBM patients and normal subjects were compared using the Student t-test. In expiration, both wall perimeter and wall thickness in TBM patients were significantly smaller than normal subjects (wall perimeter: trachea, 43.97 mm vs. 49.04 mm, p = 0.020; right main bronchus, 33.52 mm vs. 42.69 mm, p < 0.001; left main bronchus, 26.76 mm vs. 31.88 mm, p = 0.012; wall thickness: trachea, 1.89 mm vs. 2.22 mm, p = 0.017; right main bronchus, 1.64 mm vs. 1.83 mm, p = 0.021; left main bronchus, 1.61 mm vs. 1.75 mm, p = 0.016). Wall thinning and decreased perimeter of central airway of expiration by CT quantification would be a new diagnostic indicators in TBM.

  9. An Evaluation of Two Internal Surrogates for Determining the Three-Dimensional Position of Peripheral Lung Tumors

    International Nuclear Information System (INIS)

    Spoelstra, Femke; Soernsen de Koste, John R. van; Vincent, Andrew; Cuijpers, Johan P.; Slotman, Ben J.; Senan, Suresh

    2009-01-01

    Purpose: Both carina and diaphragm positions have been used as surrogates during respiratory-gated radiotherapy. We studied the correlation of both surrogates with three-dimensional (3D) tumor position. Methods and Materials: A total of 59 repeat artifact-free four-dimensional (4D) computed tomography (CT) scans, acquired during uncoached breathing, were identified in 23 patients with Stage I lung cancer. Repeat scans were co-registered to the initial 4D CT scan, and tumor, carina, and ipsilateral diaphragm were manually contoured in all phases of each 4D CT data set. Correlation between positions of carina and diaphragm with 3D tumor position was studied by use of log-likelihood ratio statistics. Models to predict 3D tumor position from internal surrogates at end inspiration (EI) and end expiration (EE) were developed, and model accuracy was tested by calculating SDs of differences between predicted and actual tumor positions. Results: Motion of both the carina and diaphragm significantly correlated with tumor motion, but log-likelihood ratios indicated that the carina was more predictive for tumor position. When craniocaudal tumor position was predicted by use of craniocaudal carina positions, the SDs of the differences between the predicted and observed positions were 2.2 mm and 2.4 mm at EI and EE, respectively. The corresponding SDs derived with the diaphragm positions were 3.7 mm and 3.9 mm at EI and EE, respectively. Prediction errors in the other directions were comparable. Prediction accuracy was similar at EI and EE. Conclusions: The carina is a better surrogate of 3D tumor position than diaphragm position. Because residual prediction errors were observed in this analysis, additional studies will be performed using audio-coached scans.

  10. National Program for Inspection of Non-Federal Dams. Paper Mill Pond Dam (CT 00621), Connecticut River Basin, Vernon, Connecticut. Phase I Inspection Report.

    Science.gov (United States)

    1981-03-01

    HYDROLOGIC AND HYDRAULIC COMPUTATIONS E INFORMATION AS CONTAINED IN THE NATIONAL INVENTORY OF DAMS ,v ’walL.it, AM I OVERVIEV \\ PHOTO Iv 390 L-( ibb~ ~5~4 N...AS-A144 539 NATIONAL PROGRAM FOR INSPEGTION 0F NON-FEDERAL DAMS / PAPER MIL POND DAM (.(U CORPS OF ENGINEERS WALTHAM A S MA NEW ENGLANA DIV MAR...CATALOG NUMBER CT 00621A 4 TITLE (amdSubtile) S. TYPE OF REPORT & PERIOD’COVERED Paper Mill Pond Dam INSPECTION REPORT NATIONAL PROGRAM FOR INSPECTION

  11. Efficacy and safety of radiofrequency ablation of hepatocellular carcinoma in the hepatic dome with the CT-guided extrathoracic transhepatic approach

    International Nuclear Information System (INIS)

    Kim, Young Kon; Kim, Chong Soo; Lee, Jeong Min; Chung, Gyung Ho; Chon, Su Bin

    2006-01-01

    Purpose: The purpose of this study was to determine the efficacy and safety of radiofrequency (RF) ablation for the treatment of hepatocellular carcinoma (HCC) in the hepatic dome with CT-guided extrathoracic transhepatic approach. Materials and methods: Fifteen patients with 15 HCCs (size range: 0.8-4 cm, mean size: 1.8 cm) in the hepatic dome were treated by RF ablation using cooled-tip electrodes and with CT-guided extrathoracic transhepatic approach. Therapeutic response of the tumor to RF ablation and procedure-related complications including hepatic injury, hemoperitoneum, and thermal injury of diaphragm were evaluated. Results: The average number of needle punctures to ensure the correct needle position in the targeted tumor was 3.7 (range: 1-6 punctures). The average ablation time was 14.7 min (range: 8-25 min). Complete necrosis without marginal recurrence after at least 13-month follow-up was attained in 13 tumors (86.7%). There were no major complications related to the procedures. Six patients had shoulder pain that lasted three days to two weeks after the procedures and their symptoms were resolved with conservative treatment. Conclusions: RF ablation using CT-guided extrathoracic transhepatic approach is an effective and safe technique for the treatment of HCC in the hepatic dome

  12. CT of abdominal abscesses

    International Nuclear Information System (INIS)

    Korobkin, M.T.

    1987-01-01

    The imaging search for a suspected abdominal abscess is common in hospitalized patients, especially after recent abdominal surgery. This paper examines the role of CT in the detection, localization, and treatment of abdominal abscess. The accuracy, limitations, and technical aspects of CT in this clinical setting are discussed. The diagnosis of an abscess is based on the demonstration of a circumscribed abnormal fluid collection. Although percutaneous aspiration with gram stain and culture is usually indicated to differentiate abscess from other fluid collections, the CT-based detection of extraluminal gas bubbles makes the diagnosis of an abscess highly likely. CT is compared with conventional radiographic studies, US, and radio-nuclide imaging. Specific CT and clinical features of abscesses in the following sites are emphasized: subphrenic space, liver, pancreas, kidneys, psoas muscle, appendix, and colonic diverticula. Most abdominal abscesses can be successfully treated with percutaneous drainage techniques. The techniques, results, and limitations of percutaneous abscess drainage are reviewed

  13. A high performance micro-pressure sensor based on a double-ended quartz tuning fork and silicon diaphragm in atmospheric packaging

    International Nuclear Information System (INIS)

    Cheng, Rongjun; Li, Cun; Zhao, Yulong; Li, Bo; Tian, Bian

    2015-01-01

    A resonant micro-pressure sensor based on a double-ended quartz tuning fork (DEQTF) and bossed silicon diaphragm in atmospheric packaging is presented. To achieve vacuum-free packaging with a high quality factor, the DEQTF is designed to resonate in an anti-phase vibration mode in a plane that is under the effect of slide-film damping. The feasibility is demonstrated by theoretical analysis and a finite element simulation. The dimensions of the DEQTF and diaphragm are optimized in accordance with the principles of improving sensitivity and minimizing energy dissipation. The sensor chip is fabricated using quartz and silicon micromachining technologies, and simply packaged in a stainless steel shell with standard atmosphere. The experimental setup is established for the calibration, where an additional sensor prototype without a pressure port is introduced as a frequency reference. By detecting the frequency difference of the tested sensor and reference sensor, the influences of environmental factors such as temperature and shocks on measuring accuracy are eliminated effectively. Under the action of a self-excitation circuit, static performance is obtained. The sensitivity of the sensor is 299 kHz kPa −1 in the operating range of 0–10 kPa at room temperature. Testing results shows a nonlinearity of 0.0278%FS, a hysteresis of 0.0207%FS and a repeatability of 0.0375%FS. The results indicate that the proposed sensor has favorable features, which provides a cost-effective and high-performance approach for low pressure measurement. (paper)

  14. Characteristics and performance of thin LaBr3(Ce) crystal for hard X-ray astronomy

    Science.gov (United States)

    Manchanda, R. K.

    2011-01-01

    We have developed a new detector using thin lanthanum bromide crystal (32 × 3 mm) for use in X-ray astronomy. The instrument was launched in high altitude balloon flight on two different occasions, December 21, 2007, which reached a ceiling altitude of 4.3 mbs and April 25, 2008 reaching a ceiling altitude 2.8 mbs. The observed background counting rate at the ceiling altitude of 4 mbs was ˜4 × 10-3 ct cm-2 s-1 keV-1 sr-1. This paper describes the details of the experiment, the detector characteristics, and the background behaviour at the ceiling altitude.

  15. Thoracic manifestation of Wegener's granulomatosis: CT findings in 30 patients

    International Nuclear Information System (INIS)

    Lee, Kyung Soo; Kim, Tae Sung; Kim, Eun A.; Fujimoto, Kiminori; Moriya, Hiroshi; Watanabe, Hideyuki; Tateishi, Ukihide; Ashizawa, Kazuoto; Johkoh, Takeshi; Kwon, O. Jung

    2003-01-01

    Our objective was to describe the CT findings of thoracic Wegener's granulomatosis. At presentation, both conventional and thin-section CT scans were available in 30 patients with Wegener's granulomatosis. Serial CT scans (range of intervals: 1-25 months, mean 4.5 months) were available in 20 patients. The initial and follow-up CT scans were analyzed retrospectively by two observers in terms of pattern and extent of parenchymal and airway lesions. Positive CT findings were seen in 29 of 30 (97%) patients at initial presentation. The most common pattern was nodules or masses seen in 27 of 30 (90%) patients. They were multiple in 23 of 27 (85%) patients, bilateral in 18 (67%), subpleural in 24 (89%), and peribronchovascular in 11 (41%) in distribution. Bronchial wall thickening in the segmental or subsegmental bronchi was seen in 22 (73%) patients. Large airways were also abnormal in 9 (30%) patients. Patchy areas of consolidation and ground-glass opacity were seen in 7 (23%) patients, respectively. In 17 of 20 (85%) patients in whom follow-up CT scans were available, the parenchymal or airway lesion showed complete or partial improvement with treatment. The CT findings of Wegener's granulomatosis, although multiple and variable, consist mainly of bilateral subpleural or peribronchovascular nodules or masses and bronchial wall thickening in the segmental or subsegmental bronchi. Parenchymal and airway lesions improve with treatment in most patients. (orig.)

  16. Clinical value of 18F-FDG PET/CT in detecting viable tumor, recurrence and metastases of hepato-cellular carcinoma after transcatheter arterial chemoembolization

    International Nuclear Information System (INIS)

    Hu Silong; Zhang Yingjian; Zhu Beiling; Shi Wei; Men Zhiqiang; Li Peilen; Jiang Guoliang

    2009-01-01

    Objective: Accurate evaluation of treatment result of transcatheter arterial chemoembolization (TACE) in patients with hepatocellular carcinoma (HCC) by conventional imaging is difficult. The objective of this study was to investigate the clinical value of 18 F-fluorodeoxyglucose (FDG) PET/CT for detecting residual viable tumor, recurrence and metastases in patients with HCC after TACE. Methods: Twenty-two patients with HCC after TACE were investigated with 18 F-FDG PET/CT. The accuracy of FDG PET/CT was determined by the histopathological results or evidences of clinical follow-up. Results: Of all 22 HCC patients after TACE, 18 had intra- and (or) extrahepatic lesions, detected by FDG PET/CT. Six-teen patients had intrahepatic FDG-avid lesion(s). Of the 16 patients, five had intrahepatic FDG-avid lesions located at both lipiodol-rich and -deprive regions, 13 had associated extrahepatic metastases. Of the two HCC patients who had no intrahepatic FDG-avid lesion, there were extrahepatic FDG-avid lesions at the retroperitoneal lymph nodes. In all, 15 HCC had extrahepatic lesions identified by FDG PET/CT. There were lung and lymph nodes (n = 9), bone (n = 2), tumor thrombus at portal vein (n - 1) and diaphragm crus (n = 1). Two patients were false negative. The sensitivity, specificity, accuracy of FDG PET/CT in detecting intra- and (or) extrahepatic lesions after TACE were 88.9% (16/18) vs 94.7 % (18/19), 4/4 vs 3/3, and 90.9% (20/22) vs 95.5% (21/22), respectively. Conclusion: 18 F-FDG PET/CT is potential useful for detection both intra- and (or) extrahepatic lesions in HCC patients after TACE. (authors)

  17. CT of chest trauma

    International Nuclear Information System (INIS)

    Goodman, P.C.

    1986-01-01

    There appears to be a limited role for computed tomography in the evaluation of chest trauma. The literature contains few papers specifically addressing the use of CT in the setting of chest trauma. Another series of articles relates anecdotal experiences in this regard. This paucity of reports attests to the remarkable amount of information present on conventional chest radiographs as well as the lack of clear indications for CT in the setting of chest trauma. In this chapter traumatic lesions of various areas of the thorax are discussed. The conventional radiographic findings are briefly described and the potential or proven application of CT is addressed

  18. Cystic thymic diseases: CT manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Song, Soon Young; Choi, Yo Won; Jeon, Eui Yong; Jeon, Seok Chol; Seo, Heung Suk; Hahm, Chang Kok [School of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1995-09-15

    To describe CT findings and differential points of cystic thymic lesions. We evaluated retrospectively total 19 masses with well marginated cystic lesions at thymic area on CT scans. They were 10 teratomas, 3 congenital thymic cysts, 2 multilocular thymic cysts(associated with thymoma and myasthenia gravis in each), 2 cysts Assciated with thymic Hodgkin's lymphomas an ectopic parathyroid cyst, and an infected thymic cyst. The radiological abnormalities evaluated were thickness of the wall, presence or abscene of septa, mural nodule, solid component, calcification and fat component. All three cases of congenital thymic cysts and an ectopic parathyroid cyst appeared as thin-walled unilocular cyst with homogeneous internal density and without identifiable solid component. In multilocular thymic cyst, there were thick wall and solid components(n =2), thick internal septa and calcifications(n = 1). The cysts of teratomas manifested thick walls(n = 9), internal septa(n = 4), calcifications(n = 6), fat components(n = 4), and solid components(n = 4). Cysts in Hodgkin's diseases appeared as multilocular or unilocular and had thick wall and septa without calcification. Infected thymic cyst presented with multilocular cystic mass with identifiable wall and septa, calcification, and solid components. The thymic diseases with cystic lesion include teratomas, congenital thymic cysts, multilocular thymic cysts, parathyroid cyst, and Hodgkin's disease. Congenital thymic cyst and ectopic parathyroid cyst are thin-walled unilocular cystic lesions. Cystic lesions associated with teratoma, Hodgkin's disease, and multilocular thymic cyst are thick-walled cystic lesions with or without solid component.

  19. Effects of heavy metals on the neuromuscular transmission of the mouse diaphragm

    Energy Technology Data Exchange (ETDEWEB)

    Fu, W M; Shiau, S Y.L.

    1978-04-01

    Effects of heavy metals including Mn, Co, Ni, Cd, Zn, Cu, Sr, Ba, and UO/sub 2//sup +/ ions on the neuromuscular transmission of the mouse diaphragm were studied and compared. From the dose-inhibition curves, the concentrations (mM) required to inhibit 50% of the contraction (ID/sub 50/) for Cd, Mn, Co, Ni, Zn and Sr are 0.03, 0.8, 0.75, 0.82, 1.2 and >20 respectively. In addition to the potent neuromuscular blocking action, both Cd and Zn induce a contracture of the mouse diaphram. Among the cations tested, Cu is the most potent in inducing the contracture. Mn does not cause a contracture, while Co and Ni induce a contracture only after a prolonged incubation for 3 hours. The neuromuscular blocking action of most of the cations tested can be completely or partially reversed by either high Ca or cysteine except the irreversible action of Zn and Cu. These findings suggest that most divalent cations block the neuromuscular transmission by binding to the -SH group of the cell membrane and inhibiting Ca influx. On the other hand, both Ba and UO/sub 2/ at low concentration increase but at high concentration inhibit the twitch response. Sine Ba increases the twitch response of the mouse diaphragm stimulated directly in the presence of d-tubocurarine as well as that stimulated indirectly, Ba/sup + +/ acts mainly directly on the muscle. In contrast, UO/sub 2//sup +/ ions at low concentration increases the twitch response possibly by releasing acetylcholine from the nerve endings.

  20. Thyroid lymphography-computed tomography (TLG-CT)

    International Nuclear Information System (INIS)

    Matsuyama, Koukichi

    1992-01-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author)