WorldWideScience

Sample records for panel passive heating

  1. Study of thermosiphon and radiant panel passive heating systems for metal buildings

    Energy Technology Data Exchange (ETDEWEB)

    Biehl, F.A.; Schnurr, N.M.; Wray, W.O.

    1983-01-01

    A study of passive-heating systems appropriate for use on metal buildings is being conducted at Los Alamos National Laboratory for the Naval Civil Engineering Laboratory, Port Hueneme, California. The systems selected for study were chosen on the basis of their appropriateness for retrofit applications, although they are also suitable for new construction: simple radiant panels that communicate directly with the building interior and a backflow thermosiphon that provides heat indirectly.

  2. Re-Active Passive devices for control of noise transmission through a panel

    Science.gov (United States)

    Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Dan

    2008-01-01

    Re-Active Passive devices have been developed to control low-frequency (transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The Re-Active Passive device uses passive constrained layer damping to cover relatively high-frequency range (>150 Hz), reactive distributed vibration absorber to cover the medium-frequency range (50-200 Hz), and active control for controlling low frequencies (transmission through a panel mounted in the Transmission Loss Test Facility at Virginia Tech. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three Re-Active Passive devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 g to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.

  3. Passive solar heating

    Energy Technology Data Exchange (ETDEWEB)

    Wiberg, K

    1981-11-10

    The present work treats the possibilities for heating according to the passive solar heating method. Problems of 'spatial organization in an energy-saving society' are distinguished from among other social problems. The final delimination of the actual problems under investigation consists of the use of passive solar heating and especially the 'consequences of such solar heating exploitation upon the form and structures' of planning and construction. In the concluding chapter an applied example shows how this method can be used in designing an urban area and what are its limitations. The results indicate the possibilities and difficulties in attempting to transfer this ideal and general method into models and directives for form and structure from which examples of the actual possibilities in practical planning can be given.

  4. Study on diverse passive decay heat removal approach

    International Nuclear Information System (INIS)

    Lin Qian; Si Shengyi

    2012-01-01

    One of the most important principles for nuclear safety is the decay heat removal in accidents. Passive decay heat removal systems are extremely helpful to enhance the safety. In currently design of many advanced nuclear reactors, kinds of passive systems are proposed or developed, such as the passive residual heat removal system, passive injection system, passive containment cooling system. These systems provide entire passive heat removal paths from core to ultimate heat sink. Various kinds of passive systems for decay heat removal are summarized; their common features or differences on heat removal paths and design principle are analyzed. It is found that, these passive decay heat removal paths are similarly common on and connected by several basic heat transfer modes and steps. By the combinations or connections of basic modes and steps, new passive decay heat removal approach or diverse system can be proposed. (authors)

  5. Passive heat removal in CANDU

    International Nuclear Information System (INIS)

    Hart, R.S.

    1997-01-01

    CANDU has a tradition of incorporating passive systems and passive components whenever they are shown to offer performance that is equal to or better than that of active systems, and to be economic. Examples include the two independent shutdown systems that employ gravity and stored energy respectively, the dousing subsystem of the CANDU 6 containment system, and the ability of the moderator to cool the fuel in the event that all coolant is lost from the fuel channels. CANDU 9 continues this tradition, incorporating a reserve water system (RWS) that increases the inventory of water in the reactor building and profiles a passive source of makeup water and/or heat sinks to various key process systems. The key component of the CANDU 9 reserve water system is a large (2500 cubic metres) water tank located at a high elevation in the reactor building. The reserve water system, while incorporating the recovery system functions, and the non-dousing functions of the dousing tank in CANDU 6, embraces other key systems to significantly extend the passive makeup/heat sink capability. The capabilities of the reserve water system include makeup to the steam generators secondary side if all other sources of water are lost; makeup to the heat transport system in the event of a leak in excess of the D 2 O makeup system capability; makeup to the moderator in the event of a moderator leak when the moderator heat sink is required; makeup to the emergency core cooling (ECC) system to assure NPSH to the ECC pumps during a loss of coolant accident (LOCA), and provision of a passive heat sink for the shield cooling system. Other passive designs are now being developed by AECL. These will be incorporated in future CANDU plants when their performance has been fully proven. This paper reviews the passive heat removal systems and features of current CANDU plants and the CANDU 9, and briefly reviews some of the passive heat removal concepts now being developed. (author)

  6. Application of heat pipes in nuclear reactors for passive heat removal

    Energy Technology Data Exchange (ETDEWEB)

    Haque, Z.; Yetisir, M., E-mail: haquez@aecl.ca [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    2013-07-01

    This paper introduces a number of potential heat pipe applications in passive (i.e., not requiring external power) nuclear reactor heat removal. Heat pipes are particularly suitable for small reactors as the demand for heat removal is significantly less than commercial nuclear power plants, and passive and reliable heat removal is required. The use of heat pipes has been proposed in many small reactor designs for passive heat removal from the reactor core. This paper presents the application of heat pipes in AECL's Nuclear Battery design, a small reactor concept developed by AECL. Other potential applications of heat pipes include transferring excess heat from containment to the atmosphere by integrating low-temperature heat pipes into the containment building (to ensure long-term cooling following a station blackout), and passively cooling spent fuel bays. (author)

  7. Re-active Passive (RAP) Devices for Control of Noise Transmission through a Panel

    Science.gov (United States)

    Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Daniel L.

    2008-01-01

    Re-Active Passive (RAP) devices have been developed to control low frequency (transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The RAP device uses passive constrained layer damping to cover the relatively high frequency range (>200 Hz), reactive distributed vibration absorber) to cover the medium frequency range (75 to 250 Hz), and active control for controlling low frequencies (transmission through a panel mounted in a transmission loss test facility. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three RAP devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 grams to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.

  8. THE USE OF PASSIVE SOLAR HEATING SYSTEMS AS PART OF THE PASSIVE HOUSE

    Directory of Open Access Journals (Sweden)

    Bryzgalin Vladislav Viktorovich

    2018-05-01

    Full Text Available Subject: systems of passive solar heating, which can, without the use of engineering equipment, capture and accumulate the solar heat used for heating buildings. Research objectives: study of the possibility to reach the passive house standard (buildings with near zero energy consumption for heating in climatic conditions of Russia using the systems of passive solar heating in combination with other solutions for reduction of energy costs of building developed in the past. Materials and methods: search and analysis of literature, containing descriptions of various passive solar heating systems, examples of their use in different climatic conditions and the resulting effect obtained from their use; analysis of thermophysical processes occurring in these systems. Results: we revealed the potential of using the solar heating systems in the climatic conditions of parts of the territories of the Russian Federation, identified the possibility of cheaper construction by the passive house standard with the use of these systems. Conclusions: more detailed analysis of thermophysical and other processes that take place in passive solar heating systems is required for creation of their computational models, which will allow us to more accurately predict their effectiveness and seek the most cost-effective design solutions, and include them in the list of means for achieving the passive house standard.

  9. Study on diverse passive decay heat removal approach and principle

    International Nuclear Information System (INIS)

    Lin Qian; Si Shengyi

    2012-01-01

    Decay heat removal in post-accident is one of the most important aspects concerned in the reactor safety analysis. Passive decay heat removal approach is used to enhance nuclear safety. In advanced reactors, decay heat is removed by multiple passive heat removal paths through core to ultimate heat sink by passive residual heat removal system, passive injection system, passive containment cooling system and so on. Various passive decay heat removal approaches are summarized in this paper, the common features and differences of their heat removal paths are analyzed, and the design principle of passive systems for decay heat removal is discussed. It is found that. these decay heat removal paths is combined by some basic heat transfer processes, by the combination of these basic processes, diverse passive decay heat removal approach or system design scheme can be drawn. (authors)

  10. Radiant heating tests of several liquid metal heat-pipe sandwich panels

    International Nuclear Information System (INIS)

    Camarda, C.J.; Basiulis, A.

    1983-08-01

    Integral heat pipe sandwich panels, which synergistically combine the thermal efficiency of heat pipes and the structural efficiency of honeycomb sandwich construction, were conceived as a means of alleviating thermal stress problems in the Langley Scramjet Engine. Test panels which utilized two different wickable honeycomb cores, facesheets with screen mesh sintered to the internal surfaces, and a liquid metal working fluid (either sodium or potassium) were tested by radiant heating at various heat load levels. The heat pipe panels reduced maximum temperature differences by 31 percent with sodium working fluid and 45 percent with potassium working fluid. Results indicate that a heat pipe sandwich panel is a potential, simple solution to the engine thermal stress problem. Other interesting applications of the concept include: cold plates for electronic component and circuit card cooling, radiators for large space platforms, low distortion large area structures (e.g., space antennas) and laser mirrors

  11. Exergy metrication of radiant panel heating and cooling with heat pumps

    International Nuclear Information System (INIS)

    Kilkis, Birol

    2012-01-01

    Highlights: ► Rational Exergy Management Model analytically relates heat pumps and radiant panels. ► Heat pumps driven by wind energy perform better with radiantpanels. ► Better CO 2 mitigation is possible with wind turbine, heat pump, radiant panel combination. ► Energy savings and thermo-mechanical performance are directly linked to CO 2 emissions. - Abstract: Radiant panels are known to be energy efficient sensible heating and cooling systems and a suitable fit for low-exergy buildings. This paper points out the little known fact that this may not necessarily be true unless their low-exergy demand is matched with low-exergy waste and alternative energy resources. In order to further investigate and metricate this condition and shed more light on this issue for different types of energy resources and energy conversion systems coupled to radiant panels, a new engineering metric was developed. Using this metric, which is based on the Rational Exergy Management Model, true potential and benefits of radiant panels coupled to ground-source heat pumps were analyzed. Results provide a new perspective in identifying the actual benefits of heat pump technology in curbing CO 2 emissions and also refer to IEA Annex 49 findings for low-exergy buildings. Case studies regarding different scenarios are compared with a base case, which comprises a radiant panel system connected to a natural gas-fired condensing boiler in heating and a grid power-driven chiller in cooling. Results show that there is a substantial CO 2 emission reduction potential if radiant panels are optimally operated with ground-source heat pumps driven by renewable energy sources, or optimally matched with combined heat and power systems, preferably running on alternative fuels.

  12. Passive heat removal system with injector-condenser

    Energy Technology Data Exchange (ETDEWEB)

    Soplenkov, K I [All-Russian Inst. of Nuclear Power Plant Operation, Electrogorsk Research and Engineering Centre of Nuclear Power Safety (Russian Federation)

    1996-12-01

    The system described in this paper is a passive system for decay heat removal from WWERs. It operates off the secondary side of the steam generators (SG). Steam is taken from the SG to operate a passive injector pump which causes secondary fluid to be pumped through a heat exchanger. Variants pass either water or steam from the SG through the heat exchanger. There is a passive initiation scheme. The programme for experimental and theoretical validation of the system is described. (author). 8 figs.

  13. Heat Transfer Characteristics of SiC-coated Heat Pipe for Passive Decay Heat Removal

    International Nuclear Information System (INIS)

    Kim, Kyung Mo; Kim, In Guk; Jeong, Yeong Shin; Bang, In Cheol

    2014-01-01

    The main concern with the Fukushima accident was the failure of active and passive core cooling systems. The main function of existing passive decay heat removal systems is feeding additional coolant to the reactor core. Thus, an established emergency core cooling system (ECCS) cannot operate properly because of impossible depressurization under the station blackout (SBO) condition. Therefore, a new concept for passive decay heat removal system is required. In this study, an innovative hybrid control rod concept is considered for passive in-core decay heat removal that differs from the existing direct vessel injection core cooling system and passive auxiliary feedwater system (PAFS). The heat transfer between the evaporator and condenser sections occurs by phase change of the working fluid and capillary action induced by wick structures installed on the inner wall of the heat pipe. In this study, a hybrid control rod is developed to take the roles of both neutron absorption and heat removal by combining the functions of a heat pipe and control rod. Previous studies on enhancing the heat removal capacity of heat pipes used nanofluids, self-rewetting fluids, various wick structures and condensers. Many studies have examined the thermal performances of heat pipes using various nanofluids. They concluded that the enhanced thermal performance of the heat pipe using nanofluids is due to nanoparticle deposition on the wick structures. Thus, the wick structure of heat pipes has been modified by nanoparticle deposition to enhance the heat removal capacity. However, previous studies used relatively small heat pipes and narrow ranges of heat loads. The environment of a nuclear reactor is very specific, and the decay heat produced by fission products after shutdown is relatively large. Thus, this study tested a large-scale heat pipe over a wide range of power. The concept of a hybrid heat pipe for an advanced in-core decay heat removal system was introduced for complete

  14. Heat Transfer Characteristics of SiC-coated Heat Pipe for Passive Decay Heat Removal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Mo; Kim, In Guk; Jeong, Yeong Shin; Bang, In Cheol [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2014-10-15

    The main concern with the Fukushima accident was the failure of active and passive core cooling systems. The main function of existing passive decay heat removal systems is feeding additional coolant to the reactor core. Thus, an established emergency core cooling system (ECCS) cannot operate properly because of impossible depressurization under the station blackout (SBO) condition. Therefore, a new concept for passive decay heat removal system is required. In this study, an innovative hybrid control rod concept is considered for passive in-core decay heat removal that differs from the existing direct vessel injection core cooling system and passive auxiliary feedwater system (PAFS). The heat transfer between the evaporator and condenser sections occurs by phase change of the working fluid and capillary action induced by wick structures installed on the inner wall of the heat pipe. In this study, a hybrid control rod is developed to take the roles of both neutron absorption and heat removal by combining the functions of a heat pipe and control rod. Previous studies on enhancing the heat removal capacity of heat pipes used nanofluids, self-rewetting fluids, various wick structures and condensers. Many studies have examined the thermal performances of heat pipes using various nanofluids. They concluded that the enhanced thermal performance of the heat pipe using nanofluids is due to nanoparticle deposition on the wick structures. Thus, the wick structure of heat pipes has been modified by nanoparticle deposition to enhance the heat removal capacity. However, previous studies used relatively small heat pipes and narrow ranges of heat loads. The environment of a nuclear reactor is very specific, and the decay heat produced by fission products after shutdown is relatively large. Thus, this study tested a large-scale heat pipe over a wide range of power. The concept of a hybrid heat pipe for an advanced in-core decay heat removal system was introduced for complete

  15. Horizontal Heat Exchanger Design and Analysis for Passive Heat Removal Systems

    Energy Technology Data Exchange (ETDEWEB)

    Vierow, Karen

    2005-08-29

    This report describes a three-year project to investigate the major factors of horizontal heat exchanger performance in passive containment heat removal from a light water reactor following a design basis accident LOCA (Loss of Coolant Accident). The heat exchanger studied in this work may be used in advanced and innovative reactors, in which passive heat removal systems are adopted to improve safety and reliability The application of horizontal tube-bundle condensers to passive containment heat removal is new. In order to show the feasibility of horizontal heat exchangers for passive containment cooling, the following aspects were investigated: 1. the condensation heat transfer characteristics when the incoming fluid contains noncondensable gases 2. the effectiveness of condensate draining in the horizontal orientation 3. the conditions that may lead to unstable condenser operation or highly degraded performance 4. multi-tube behavior with the associated secondary-side effects This project consisted of two experimental investigations and analytical model development for incorporation into industry safety codes such as TRAC and RELAP. A physical understanding of the flow and heat transfer phenomena was obtained and reflected in the analysis models. Two gradute students (one funded by the program) and seven undergraduate students obtained research experience as a part of this program.

  16. Thermophysiological adaptations to passive mild heat acclimation

    NARCIS (Netherlands)

    Pallubinsky, H; Schellen, L; Kingma, B R M; Dautzenberg, B; van Baak, M A; van Marken Lichtenbelt, W D

    Passive mild heat acclimation (PMHA) reflects realistic temperature challenges encountered in everyday life. Active heat acclimation, combining heat exposure and exercise, influences several important thermophysiological parameters; for example, it decreases core temperature and enhances heat

  17. Study on thermal-hydraulic phenomena identification of passive heat removal facilities

    International Nuclear Information System (INIS)

    Park, J. Y.

    2011-01-01

    Recently, passive heat removal facilities have been integral features of new generation or future reactor designs worldwide. This is because the passive heat removal facilities depending on a natural force such as buoyancy can give much higher operational reliability compared to active heat removal facilities depending on pumped fluid flow and as a result they can decrease core damage frequency of a nuclear power plant drastically ever achievable before. Keeping pace with this global trend, SMART and APR+ reactors also have introduced passive heat removal features such as a passive residual heat removal system (PRHRS) and a passive auxiliary feed water system (PAFS) in their designs. Since many thermal-hydraulic (T-H) phenomena including steam condensation are involved during operation of the passive heat removal facilities, they ought to be properly simulated by T-H codes such as MARS-KS and RELAP5 in order to guarantee reliable safety analysis by these codes. Unfortunately, however, these T-H codes are not well validated with respect to phenomena related to passive heat removal mechanism because previous focus on these codes validation was mainly on the LB LOCA and resulting phenomena. To resolve this gap, Korea Institute of Nuclear Safety has initiated a research program on the development of safety analysis technology for passive heat removal facilities. The main target of this program is PRHRS and PAFS in SMART and APR+ reactors and through this program, validation of capability of existing T-H codes and improvement of codes regarding passive facilities analysis are to be sought. In part of this research, T-H phenomena important to passive heat removal facilities (PRHRS and PAFS) are investigated in the present study

  18. Passive heat removal characteristics of SMART

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jae Kwang; Kang, Hyung Seok; Yoon, Joo Hyun; Kim, Hwan Yeol; Cho, Bong Hyun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    A new advanced integral reactor of 330 MWt thermal capacity named SMART (System-Integrated Modular Advanced Reactor) is currently under development in Korea Atomic Energy Research Institute (KAERI) for multi-purpose applications. Modular once-through steam generator (SG) and self-pressurizing pressurizer equipped with wet thermal insulator and cooler are essential components of the SMART. The SMART provides safety systems such as Passive Residual Heat Removal System (PRHRS). In this study, a computer code for performance analysis of the PRHRS is developed by modeling relevant components and systems of the SMART. Using this computer code, a performance analysis of the PRHRS is performed in order to check whether the passive cooling concept using the PRHRS is feasible. The results of the analysis show that PRHRS of the SMART has excellent passive heat removal characteristics. 2 refs., 4 figs., 1 tab. (Author)

  19. Heat Rejection from a Variable Conductance Heat Pipe Radiator Panel

    Science.gov (United States)

    Jaworske, D. A.; Gibson, M. A.; Hervol, D. S.

    2012-01-01

    A titanium-water heat pipe radiator having an innovative proprietary evaporator configuration was evaluated in a large vacuum chamber equipped with liquid nitrogen cooled cold walls. The radiator was manufactured by Advanced Cooling Technologies, Inc. (ACT), Lancaster, PA, and delivered as part of a Small Business Innovative Research effort. The radiator panel consisted of five titanium-water heat pipes operating as thermosyphons, sandwiched between two polymer matrix composite face sheets. The five variable conductance heat pipes were purposely charged with a small amount of non-condensable gas to control heat flow through the condenser. Heat rejection was evaluated over a wide range of inlet water temperature and flow conditions, and heat rejection was calculated in real-time utilizing a data acquisition system programmed with the Stefan-Boltzmann equation. Thermography through an infra-red transparent window identified heat flow across the panel. Under nominal operation, a maximum heat rejection value of over 2200 Watts was identified. The thermal vacuum evaluation of heat rejection provided critical information on understanding the radiator s performance, and in steady state and transient scenarios provided useful information for validating current thermal models in support of the Fission Power Systems Project.

  20. Investigation of Condensation Heat Transfer Correlation of Heat Exchanger Design in Secondary Passive Cooling System

    Energy Technology Data Exchange (ETDEWEB)

    Ju, Yun Jae; Lee, Hee Joon [Kookmin Univ., Seoul (Korea, Republic of); Kang, Hanok; Lee, Taeho; Park, Cheontae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-12-15

    Recently, condensation heat exchangers have been studied for applications to the passive cooling systems of nuclear plants. To design vertical-type condensation heat exchangers in secondary passive cooling systems, TSCON (Thermal Sizing of CONdenser), a thermal sizing program for a condensation heat exchanger, was developed at KAERI (Korea Atomic Energy Research Institute). In this study, the existing condensation heat transfer correlation of TSCON was evaluated using 1,157 collected experimental data points from the heat exchanger of a secondary passive cooling system for the case of pure steam condensation. The investigation showed that the Shah correlation, published in 2009, provided the most satisfactory results for the heat transfer coefficient with a mean absolute error of 34.8%. It is suggested that the Shah correlation is appropriate for designing a condensation heat exchanger in TSCON.

  1. Development of Passive Fuel Cell Thermal Management Heat Exchanger

    Science.gov (United States)

    Burke, Kenneth A.; Jakupca, Ian J.; Colozza, Anthony J.

    2010-01-01

    The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA Exploration program. The passive thermal management system relies on heat conduction within highly thermally conductive cooling plates to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack. Using the passive approach eliminates the need for a coolant pump and other cooling loop components within the fuel cell system which reduces mass and improves overall system reliability. Previous development demonstrated the performance of suitable highly thermally conductive cooling plates that could conduct the heat, provide a sufficiently uniform temperature heat sink for each cell of the fuel cell stack, and be substantially lighter than the conventional thermal management approach. Tests were run with different materials to evaluate the design approach to a heat exchanger that could interface with the edges of the passive cooling plates. Measurements were made during fuel cell operation to determine the temperature of individual cooling plates and also to determine the temperature uniformity from one cooling plate to another.

  2. PWR passive plant heat removal assessment: Joint EPRI-CRIEPI advanced LWR studies

    International Nuclear Information System (INIS)

    1991-03-01

    An independent assessment of the capabilities of the PWR passive plant heat removal systems was performed, covering the Passive Residual Heat Removal (PRHR) System, the Passive Safety Injection System (PSIS) and the Passive Containment Cooling System (PCCS) used in a 600 MWe passive plant (e.g., AP600). Additional effort included a review of the test programs which support the design and analysis of the systems, an assessment of the licensability of the plant with regard to heat removal adequacy, and an evaluation of the use of the passive systems with a larger plant. The major conclusions are as follows. The PRHR can remove core decay heat, prevents the pressurizer from filling with water for a loss-of-feedwater transient, and provides safety-grade means for maintaining the reactor coolant system in a safe shutdown condition for the case where the non-safety residual heat removal system becomes unavailable. The PSIS is effective in maintaining the core covered with water for loss-of-coolant accident pipe breaks to eight inches. The PCCS has sufficient heat removal capability to maintain the containment pressure within acceptable limits. The tests performed and planned are adequate to confirm the feasibility of the passive heat removal system designs and to provide a database for verification of the analytical techniques used for the plant evaluations. Each heat removal system can perform in accordance with Regulatory requirements, with the exception that the PRHR system is unable to achieve the required cold shutdown temperature of 200 F within the required 36-hour period. The passive heat removal systems to be used for the 600 MWe plant could be scaled up to a 900 MWe passive plant in a straightforward manner and only minimal, additional confirmatory testing would be required. Sections have been indexed separately for inclusion on the data base

  3. Feasibility of passive heat removal systems

    Energy Technology Data Exchange (ETDEWEB)

    Ashurko, Yu M [Institute of Physics and Power Engineering, Obninsk (Russian Federation)

    1996-12-01

    This paper presents a review of decay heat removal systems (DHRSs) used in liquid metal-cooled fast reactors (LMFRs). Advantages and the disadvantages of these DHRSs, extent of their passivity and prospects for their use in advanced fast reactor projects are analyzed. Methods of extending the limitations on the employment of individual systems, allowing enhancement in their effectiveness as safety systems and assuring their total passivity are described. (author). 10 refs, 10 figs.

  4. High performance passive solar heating system with heat pipe energy transfer and latent heat storage

    NARCIS (Netherlands)

    Dijk, van H.A.L.; Galen, van E; Hensen, J.L.M.; Wit, de M.H.

    1983-01-01

    Preliminar results are reported from a current project on the development of a high performance passive solar heating system. Two special components are introduced: a. A heat pipe as a thermal diode tube for the efficient transfer of collected solar heat from the absorber plate to behind an

  5. High performance passive solar heating system with heat pipe energy transfer

    NARCIS (Netherlands)

    Wit, de M.H.; Hensen, J.L.M.; Dijk, van H.A.L.; Brink, van den G.J.; Galen, van E; Ouden, den C.

    1984-01-01

    The aim of the project is to develop a passive solar heating system with a higher efficiency (regarding accumulation and transfer of solar heat into dwellings) than convential concrete thermal storage walls and with restricted extra costs for manufacturing the system. This is to be achieved by the

  6. Enhancing Convective Heat Transfer over a Surrogate Photovoltaic Panel

    Science.gov (United States)

    Fouladi, Fama

    This research is particularly focused on studying heat transfer enhancement of a photovoltaic (PV) panel by putting an obstacle at the panel's windward edge. The heat transfer enhancement is performed by disturbing the airflow over the surface and increasing the heat and momentum transfer. Different objects such as triangular, square, rectangular, and discrete rectangular ribs and partial grids were applied at the leading edge of a surrogate PV panel and flow and the heat transfer of the panel are investigated experimentally. This approach was selected to expand understanding of effect of these different objects on the flow and turbulence structures over a flat surface by analyzing the flow comprehensively. It is observed that, a transverse object at the plate's leading edge would cause some flow blockage in the streamwise direction, but at the same time creates some velocity in the normal and cross stream directions. In addition to that, the obstacle generates some turbulence over the surface which persists for a long downstream distance. Also, among all studied objects, discrete rectangular ribs demonstrate the highest heat transfer rate enhancement (maximum Nu/Nu0 of 1.5). However, ribs with larger gap ratios are observed to be more effective at enhancing the heat transfer augmentation at closer distances to the rib, while at larger downstream distances from the rib, discrete ribs with smaller gap ratios are more effective. Furthermore, this work attempted to recognize the most influential flow parameters on the heat transfer enhancement of the surface. It is seen that the flow structure over a surface downstream of an object (flow separation-reattachment behaviour) has a significant effect on the heat transfer enhancement trend. Also, turbulence intensities are the most dominant parameters in enhancing the heat transfer rate from the surface; however, flow velocity (mostly normal velocity) is also an important factor.

  7. Ocular blood flow decreases during passive heat stress in resting humans.

    Science.gov (United States)

    Ikemura, Tsukasa; Miyaji, Akane; Kashima, Hideaki; Yamaguchi, Yuji; Hayashi, Naoyuki

    2013-12-06

    Heat stress induces various physiological changes and so could influence ocular circulation. This study examined the effect of heat stress on ocular blood flow. Ocular blood flow, end-tidal carbon dioxide (P(ET)CO2) and blood pressure were measured for 12 healthy subjects wearing water-perfused tube-lined suits under two conditions of water circulation: (1) at 35 °C (normothermia) for 30 min and (2) at 50 °C for 90 min (passive heat stress). The blood-flow velocities in the superior temporal retinal arteriole (STRA), superior nasal retinal arteriole (SNRA), and the retinal and choroidal vessels (RCV) were measured using laser-speckle flowgraphy. Blood flow in the STRA and SNRA was calculated from the integral of a cross-sectional map of blood velocity. PETCO2 was clamped at the normothermia level by adding 5% CO2 to the inspired gas. Passive heat stress had no effect on the subjects' blood pressures. The blood-flow velocity in the RCV was significantly lower after 30, 60 and 90 min of passive heat stress than the normothermic level, with a peak decrease of 18 ± 3% (mean ± SE) at 90 min. Blood flow in the STRA and SNRA decreased significantly after 90 min of passive heat stress conditions, with peak decreases of 14 ± 3% and 14 ± 4%, respectively. The findings of this study suggest that passive heat stress decreases ocular blood flow irrespective of the blood pressure or arterial partial pressure of CO2.

  8. Solar passive ceiling system. Final report. [Passive solar heating system with venetian blind reflectors and latent heat storage in ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, A.R.

    1980-01-01

    The construction of a 1200 square foot building, with full basement, built to be used as a branch library in a rural area is described. The primary heating source is a passive solar system consisting of a south facing window system. The system consists of: a set of windows located in the south facing wall only, composed of double glazed units; a set of reflectors mounted in each window which reflects sunlight up to the ceiling (the reflectors are similar to venetian blinds); a storage area in the ceiling which absorbs the heat from the reflected sunlight and stores it in foil salt pouches laid in the ceiling; and an automated curtain which automatically covers and uncovers the south facing window system. The system is totally passive and uses no blowers, pumps or other active types of heat distribution equipment. The building contains a basement which is normally not heated, and the north facing wall is bermed four feet high around the north side.

  9. Renewable energy for passive house heating. Part 1. Building description

    Energy Technology Data Exchange (ETDEWEB)

    Badescu, V. [Polytechnic Univ., Bucharest (Romania). Faculty of Mechanical Engineering; Sicre, B. [Technical Univ., Chemnitz (Germany). Computational Physics

    2003-12-01

    A passive house is a cost-efficient building that can manage throughout the heating period, due to its specific construction design, with more than 10 times less heat energy than the same building designed to standards presently applicable across Europe. Its extended thermal insulation and enhanced air-tightness removes the need for temperatures higher than 50 {sup o}C. This makes renewable energy sources particularly suitable for heating, cooling and domestic hot water production. Modeling of renewable energy usage for space heating requires as a preliminary stage the detailed description of the building structure, of the HVAC equipment and of the internal heat sources. This paper shows the main data used to model the thermal behavior of a passive house. Details about Pirmasens Passive House (Rhineland Palatinate, Germany) are given, as for example, the internal heat sources, including electric appliances, heat and humidity released by human bodies, thermal internal facilities as hot and cold water pipes. All these are quantified by using statistically derived data. A detailed time schedule for a standard German family with two adults and two children was prepared. It takes into account the national celebrations, vacation and weekends among others. (Author)

  10. Molecular dynamics study of solid-liquid heat transfer and passive liquid flow

    Science.gov (United States)

    Yesudasan Daisy, Sumith

    High heat flux removal is a challenging problem in boilers, electronics cooling, concentrated photovoltaic and other power conversion devices. Heat transfer by phase change is one of the most efficient mechanisms for removing heat from a solid surface. Futuristic electronic devices are expected to generate more than 1000 W/cm2 of heat. Despite the advancements in microscale and nanoscale manufacturing, the maximum passive heat flux removal has been 300 W/cm2 in pool boiling. Such limitations can be overcome by developing nanoscale thin-film evaporation based devices, which however require a better understanding of surface interactions and liquid vapor phase change process. Evaporation based passive flow is an inspiration from the transpiration process that happens in trees. If we can mimic this process and develop heat removal devices, then we can develop efficient cooling devices. The existing passive flow based cooling devices still needs improvement to meet the future demands. To improve the efficiency and capacity of these devices, we need to explore and quantify the passive flow happening at nanoscales. Experimental techniques have not advanced enough to study these fundamental phenomena at the nanoscale, an alternative method is to perform theoretical study at nanoscales. Molecular dynamics (MD) simulation is a widely accepted powerful tool for studying a range of fundamental and engineering problems. MD simulations can be utilized to study the passive flow mechanism and heat transfer due to it. To study passive flow using MD, apart from the conventional methods available in MD, we need to have methods to simulate the heat transfer between solid and liquid, local pressure, surface tension, density, temperature calculation methods, realistic boundary conditions, etc. Heat transfer between solid and fluids has been a challenging area in MD simulations, and has only been minimally explored (especially for a practical fluid like water). Conventionally, an

  11. Performance improvement of the finned passive PVT system using reflectors like removable insulation covers

    International Nuclear Information System (INIS)

    Ziapour, Behrooz M.; Palideh, Vahid; Mokhtari, Farhad

    2016-01-01

    Highlights: • A passive PVT system means the combination of a PV panel and a compact solar water heater. • Comparative study was done on performance characteristics in passive and hybrid PVT systems. • Reflectors effects on performance of a finned passive PVT system were numerically studied. • Results show that the finned passive PVT system has higher performance than the hybrid type. • Reflectors reduce the night heat losses and increase the solar radiation rate on PVT system. - Abstract: A passive photovoltaic–thermal system (PVT) is the combination of a photovoltaic (PV) panel and a compact solar water heater for co-generation of heat and electricity. This system bears considerable heat losses to ambient, particularly at noncollection times. One simple way to overcome this problem is to use a removable insulation cover on the collector's outer glazing. In this paper, the effects of the reflectors on day and night performance of a finned passive PVT system were numerically studied. At nonenergy collection time, the reflectors can turn and cover the collector cover glass as a nonconductor material. Simulation results showed that the reflectors reduce the night heat losses and increase the solar radiation rate on the absorber plate. The use of removable insulation reflectors resulted to saving extra sensibly thermal energy. Also, the solar cells power generation (P_s_c), in the case of reflectors installed, was reinforced.

  12. Passive Decay Heat Removal System for Micro Modular Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jangsik; Lee, Jeong Ik; Jeong, Yong Hoon [KAIST, Daejeon (Korea, Republic of)

    2015-10-15

    Dry cooling system is applied as waste heat removal system therefore it is able to consider wide construction site. Schematic figure of the reactor is shown in Fig. 1. In safety features, the reactor has double containment and passive decay heat removal (PDHR) system. The double containment prevents leakage from reactor coolant system to be emitted into environment. The passive decay heat removal system copes with design basis accidents (DBAs). Micros Modular Reactor (MMR) which has been being developed in KAIST is S-CO{sub 2} gas cooled reactor and shows many advantages. The S-CO{sub 2} power cycle reduces size of compressor, and it makes small size of power plant enough to be transported by trailer.The passive residual heat removal system is designed and thermal hydraulic (TH) analysis on coolant system is accomplished. In this research, the design process and TH analysis results are presented. PDHR system is designed for MMR and coolant system with the PDHR system is analyzed by MARS-KS code. Conservative assumptions are applied and the results show that PDHR system keeps coolant system under the design limitation.

  13. PV Thermal systems: PV panels supplying renewable electricity and heat

    NARCIS (Netherlands)

    Helden, van W.G.J.; Zolingen, van R.J.C.; Zondag, H.A.

    2004-01-01

    With PV Thermal panels sunlight is converted into electricity and heat simultaneously. Per unit area the total efficiency of a PVT panel is higher than the sum of the efficiencies of separate PV panels and solar thermal collectors. During the last 20 years research into PVT techniques and concepts

  14. Transient Performance of Air-cooled Condensing Heat Exchanger in Long-term Passive Cooling System during Decay Heat Load

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myoung Jun; Lee, Hee Joon [Kookmin University, Seoul (Korea, Republic of); Moon, Joo Hyung; Bae, Youngmin; Kim, Young-In [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    In the event of a 'loss of coolant accident'(LOCA) and a non-LOCA, the secondary passive cooling system would be activated to cool the steam in a condensing heat exchanger that is immersed in an emergency cooldown tank (ECT). Currently, the capacities of these ECTs are designed to be sufficient to remove the sensible and residual heat from the reactor coolant system for 72 hours after the occurrence of an accident. After the operation of a conventional passive cooling system for an extended period, however, the water level falls as a result of the evaporation from the ECT, as steam is emitted from the open top of the tank. Therefore, the tank should be refilled regularly from an auxiliary water supply system when the system is used for more than 72 hours. Otherwise, the system would fail to dissipate heat from the condensing heat exchanger due to the loss of the cooling water. Ultimately, the functionality of the passive cooling system would be seriously compromised. As a passive means of overcoming the water depletion in the tank, Kim et al. applied for a Korean patent covering the concept of a long-term passive cooling system for an ECT even after 72 hours. This study presents transient performance of ECT with installing air-cooled condensing heat exchanger under decay heat load. The cooling capacity of an air-cooled condensing heat exchanger was evaluated to determine its practicality.

  15. Performance of the prism reactor's passive decay heat removal system

    International Nuclear Information System (INIS)

    Magee, P.M.; Hunsbedt, A.

    1989-01-01

    The PRISM modular reactor concept has a totally passive safety-grade decay heat removal system referred to as the Reactor Vessel Auxiliary Cooling System (RVACS) that rejects heat from the reactor by radiation and natural convection of air. The system is inherently reliable and is not subject to the failure modes commonly associated with active cooling systems. The thermal performance of RVACS exceeds requirements and significant thermal margins exist. RVACS has been shown to perform its function under many postulated accident conditions. The PRISM power plant is equipped with three methods for shutdown: condenser cooling in conjunction with intermediate sodium and steam generator systems, and auxiliary cooling system (ACS) which removes heat from the steam generator by natural convection of air and transport of heat from the core by natural convection in the primary and intermediate systems, and a safety- grade reactor vessel auxiliary cooling system (RVACS) which removes heat passively from the reactor containment vessel by natural convection of air. The combination of one active and two passive systems provides a highly reliable and economical shutdown heat removal system. This paper provides a summary of the RVACS thermal performance for expected operating conditions and postulated accident events. The supporting experimental work, which substantiates the performance predictions, is also summarized

  16. Modelling of passive heating for replication of sub-micron patterns in optical disk substrates

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Youngmin; Bae, Jaecheol; Kim, Hongmin; Kang, Shinill [School of Mechanical Engineering, Yonsei University, 134 Shinchon-dong, Seodaemoon-ku, Seoul (Korea, Republic of)

    2004-05-07

    The transcribability of pit or land groove structures in replicating an optical disk substrate greatly affects the performance of a high-density optical disk. However, a solidified layer generated during the polymer filling worsens transcribability because the solidified layer prevents the polymer melt from filling the sub-micron patterns. Therefore, the development of the solidified layer during the filling stage of injection moulding must be delayed. For this delay, passive heating through an insulation layer has been used. In the present study, to examine the development of the solidified layer, delayed by passive heating, the flow of the polymer melt with passive heating was analysed. Passive heating delayed markedly the development of the solidified layer, reduced the viscosity of the polymer melt, and increased the fluidity of the polymer melt in the vicinity of the stamper surface with the sub-micron patterns. As a result, we predict that passive heating can improve the transcribability of an optical disk substrate. To verify our prediction, we fabricated an optical disk substrate by using passive heating of a mould and measured the transcribability of an optical disk substrate.

  17. Modelling of passive heating for replication of sub-micron patterns in optical disk substrates

    International Nuclear Information System (INIS)

    Kim, Youngmin; Bae, Jaecheol; Kim, Hongmin; Kang, Shinill

    2004-01-01

    The transcribability of pit or land groove structures in replicating an optical disk substrate greatly affects the performance of a high-density optical disk. However, a solidified layer generated during the polymer filling worsens transcribability because the solidified layer prevents the polymer melt from filling the sub-micron patterns. Therefore, the development of the solidified layer during the filling stage of injection moulding must be delayed. For this delay, passive heating through an insulation layer has been used. In the present study, to examine the development of the solidified layer, delayed by passive heating, the flow of the polymer melt with passive heating was analysed. Passive heating delayed markedly the development of the solidified layer, reduced the viscosity of the polymer melt, and increased the fluidity of the polymer melt in the vicinity of the stamper surface with the sub-micron patterns. As a result, we predict that passive heating can improve the transcribability of an optical disk substrate. To verify our prediction, we fabricated an optical disk substrate by using passive heating of a mould and measured the transcribability of an optical disk substrate

  18. Scaling for Mixed Convection Heat Transfer in Passive Containments and Experiment Design

    International Nuclear Information System (INIS)

    Wang, Shengfei; Yu, Yu; Lv, Xuefeng; Niu, Fenglei; Yan, Xiuping

    2012-01-01

    Most of the advanced nuclear reactor design utilizes passive systems to remove heat from the core by natural circulation. The passive systems will be widely used in generation III pressurized water reactor. One of the typical passive systems is passive containment cooling system (PCCS), which is a passive condenser system designed to remove heat from the containment for long term cooling after a postulated reactor accident. In order to establish empirical correlations and develop simulation models, a scaling analysis is performed in designing an experiment for the prototype PCCS. This paper presents a scaling method and the design of the experimental facility. The key dimensionless parameters governing the dominant processes are given at last

  19. Behavior study on Na heat pipe in passive heat removal system of new concept molten salt reactor

    International Nuclear Information System (INIS)

    Wang Chenglong; Tian Wenxi; Su Guanghui; Zhang Dalin; Wu Yingwei; Qiu Suizheng

    2013-01-01

    The high temperature Na heat pipe is an effective device for transporting heat, which is characterized by remarkable advantages in conductivity, isothermally and passively working. The application of Na heat pipe on passive heat removal system of new concept molten salt reactor (MSR) is significant. The transient performance of high temperature Na heat pipe was simulated by numerical method under the MSR accident. The model of the Na heat pipe was composed of three conjugate heat transfer zones, i.e. the vapor, wick and wall. Based on finite element method, the governing equations were solved by making use of FORTRAN to acquire the profiles of the temperature, velocity and pressure for the heat pipe transient operation. The results show that the high temperature Na heat pipe has a good performance on operating characteristics and high heat transfer efficiency from the frozen state. (authors)

  20. AEA studies on passive decay heat removal in advanced reactors

    International Nuclear Information System (INIS)

    Lillington, J.N.

    1994-01-01

    The main objectives of the UK study were: to identify, describe and compare different types of systems proposed in current designs; to identify key scenarios in which passive decay heat removal systems play an important preventative or mitigative role; to assess the adequacy of the relevant experimental database; to assess the applicability and suitability of current generation models/codes for predicting passive decay heat removal; to assess the potential effectiveness of different systems in respect of certain key licensing questions

  1. Passive decay heat removal from the core region

    International Nuclear Information System (INIS)

    Hichen, E.F.; Jaegers, H.

    2002-01-01

    The decay heat in commercial Light Water Reactors is commonly removed by active and redundant safety systems supported by emergency power. For advanced power plant designs passive safety systems using a natural circulation mode are proposed: several designs are discussed. New experimental data gained with the NOKO and PANDA facilities as well as operational data from the Dodewaard Nuclear Power Plant are presented and compared with new calculations by different codes. In summary, the effectiveness of these passive decay heat removal systems have been demonstrated: original geometries and materials and for the NOKO facility and the Dodewaard Reactor typical thermal-hydraulic inlet and boundary conditions have been used. With several codes a good agreement between calculations and experimental data was achieved. (author)

  2. Performance in cooling mode of a heat pump using panels with PV cells as the condenser; Taiyo denchitsuki panel wo gyoshukuki to shita heat pump no reibo unten

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, T; Ito, S; Miura, N [Kanagawa Institute of Technology, Kanagawa (Japan); Fujita, M [Chubu Electric Power Co. Inc., Nagoya (Japan)

    1996-10-27

    Comparison was made between heat pumps in cooling operation, one having two panels provided with solar cells, the second having an air-cooled heat exchanger alone, and the third having a series connection of a panel unit and air-cooled heat exchanger, all serving as condenser. The results are shown below. In the case of two-panel-unit condenser, there is a difference ({Delta}t) of 15{degree}C between the daytime free air temperature and condensing temperature but, with decreased insolation, free air temperature, and wind speed in the evening, the {Delta}t lowered to approximately 8{degree}C while the COP (coefficient of performance) increased from 2.4 to 3.3. On a cloudy day in summer, the two-panel-unit condenser had a {Delta}t of 13.9{degree}C and a COP of 3.1. In the case of the series-connection condenser, the {Delta}t was approximately 8{degree}C and the COP was 3.5. The COP of the two-panel-unit condenser was lower than that of the air-cooled heat exchanger by 9% at an insolation of 442W/m{sup 2} but it rose to 12% in the absence of insolation. The COP of the two-panel-unit condenser was higher than that of a one-panel-unit condenser by 17%. When an insulator plate was attached to the back of a panel, the {Delta}t increased but the COP decreased by 14%. In the case of the series-connection condenser, the COP increased by 6% in the absence of the insulator plate. 2 refs., 9 figs.

  3. Passive safety systems for decay heat removal of MRX

    Energy Technology Data Exchange (ETDEWEB)

    Ochiai, M; Iida, H; Hoshi, T [Japan Atomic Energy Research Inst., Ibaraki (Japan). Nuclear Ship System Lab.

    1996-12-01

    The MRX (marine Reactor X) is an advanced marine reactor, its design has been studied in Japan Atomic Energy Research Institute. It is characterized by four features, integral type PWR, in-vessel type control rod drive mechanisms, water-filled containment vessel and passive decay heat removal system. A water-filled containment vessel is of great advantage since it ensures compactness of a reactor plant by realizing compact radiation shielding. The containment vessel also yields passive safety of MRX in the event of a LOCA by passively maintaining core flooding without any emergency water injection. Natural circulation of water in the vessels (reactor and containment vessels) is one of key factors of passive decay heat removal systems of MRX, since decay heat is transferred from fuel rods to atmosphere by natural circulation of the primary water, water in the containment vessel and thermal medium in heat pipe system for the containment vessel water cooling in case of long terms cooling after a LOCA as well as after reactor scram. Thus, the ideal of water-filled containment vessel is considered to be very profitable and significant in safety and economical point of view. This idea is, however, not so familiar for a conventional nuclear system, so experimental and analytical efforts are carried out for evaluation of hydrothermal behaviours in the reactor pressure vessel and in the containment vessel in the event of a LOCA. The results show the effectiveness of the new design concept. Additional work will also be conducted to investigate the practical maintenance of instruments in the containment vessel. (author). 4 refs, 9 figs, 2 tabs.

  4. Influence of heat treatment on microstructure and passivity of Cu ...

    Indian Academy of Sciences (India)

    200 ◦C for 20 h in salt bath and air cooled), B (heating up to 800 ◦C for 20 h and water ... chloride ions on passivity was associated with the formation of copper oxides/hydroxide and ... passive layer inhibits copper redeposition and/or preferen-.

  5. Passive cooling applications for nuclear power plants using pulsating steam-water heat pipes

    International Nuclear Information System (INIS)

    Aparna, J.; Chandraker, D.K.

    2015-01-01

    Gen IV reactors incorporate passive principles in their system design as an important safety philosophy. Passive safety systems use inherent physical phenomena for delivering the desired safe action without any external inputs or intrusion. The accidents in Fukushima have renewed the focus on passive self-manageable systems capable of unattended operation, for long hours even in extended station blackout (SBO) and severe accident conditions. Generally, advanced reactors use water or atmospheric air as their ultimate heat sink and employ passive principles in design for enhanced safety. This paper would be discussing the experimental results on pulsating steam water heat-pipe devices and their applications in passive cooling. (author)

  6. Prediction of Heat Transfer Performance on Horizontal U-Shaped Heat Exchanger in Passive Safety System Using MARS

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Seong-Su; Hong, Soon-Joon [FNC Tech, Yongin (Korea, Republic of); Cho, Hyoung-Kyu; Park, Goon-Cherl [Seoul National University, Seoul (Korea, Republic of)

    2015-10-15

    The design and the safety analysis of the passive safety systems are performed mainly using the best-estimate thermal-hydraulic analysis codes such as RELAP5 and MARS. This study developed the heat transfer model package for the horizontal U-shaped HX submerged in a pool by improving the horizontal in-tube condensation model and developing the outside-tube natural convective nucleate boiling model. This paper presents the HX model package and the validation results against the passive safety system-related experimental data of PASCAL and ATLAS-PAFS. This study developed the heat transfer model package of the horizontal U-shaped HX submerged in a pool in order to obtain a reliable prediction of the HX heat removal performance of the passive safety system, especially PAFS, using MARS. From the validation results, the proposed model package provided the improved prediction of HX performance (condensation, natural convective nucleate boiling, and heat removal rate of the HX) compared to the default model in MARS.

  7. Numerical investigation of passive heat removal system via steam generator in VVER 1200

    International Nuclear Information System (INIS)

    Dinh Anh Tuan; Duong Thanh Tung; Tran Chi Thanh; Nguyen Van Thai

    2015-01-01

    Passive heat removal system (PHRS) via Steam Generator is an important part in VVER design. In case of Design Basic Accidents such as blackout, failure of feed water supply to steam generator or coolant leakage with failure of emergency core cooling at high pressure. PHRS is designed to remove the residual heat from reactor core through steam generator to heat exchanger which is placed outside reactor vessel. In order to evaluate the passive system, a numerical investigation using a CFD code is performed. However, PHRS has complex geometry for using CFD simulation. Thus, RELAP5 is applied to provide the wall heat flux of tube in the heat exchanger tank. The natural convection in the heat exchanger tank is investigated in this report. Numerical results show temperature and velocity distribution in the heat exchanger tank are calculated with different wall heat flux corresponding to various transient conditions. The calculated results contribute to the capacity analysis of passive heat removal system and giving valuable information for safe operation of VVER 1200. (author)

  8. Passive acoustic radiation control for a vibrating panel with piezoelectric shunt damping circuit using particle swarm optimization algorithm

    International Nuclear Information System (INIS)

    Jeon, Jin Young

    2009-01-01

    This paper presents a new acoustic radiation optimization method for a vibrating panel-like structure with a passive piezoelectric shunt damping system in order to minimize well-radiating modes generated from the panel. The optimization method is based on an idea of using the p-version finite element method(p-version FEM), the boundary element method(BEM), and the particle swarm optimization algorithm(PSOA). Optimum embossment design for the vibrating panel using the PSOA is first investigated in order to minimize noise radiation over a frequency range of interest. The optimum embossment design works as a kind of stiffener so that well-radiating natural modes are shifted up with some degrees. The optimized panel, however, may still require additional damping for attenuating the peak acoustic amplitudes. A passive shunt damping system is thus employed to additionally damp the well-radiating modes from the optimized panel. To numerically evaluate the acoustic multiple-mode damping capability by a shunt damping system, the integrated p-version FEM/BEM for the panel with the shunt damping system is modeled and developed by MATLAB. Using the PSOA, the optimization technique for the optimal multiple-mode shunt damper is investigated in order to achieve the optimum damping performance for the well-radiating modes simultaneously. Also, the acoustic damping performance of the shunt damping circuit in the acoustic environment is demonstrated numerically and experimentally with respect to the realistically sized panel. The simulated result shows a good agreement with that of the experimental result

  9. Passive heat transport in advanced CANDU containment

    International Nuclear Information System (INIS)

    Krause, M.; Mathew, P.M.

    1994-01-01

    A passive CANDU containment design has been proposed to provide the necessary heat removal following a postulated accident to maintain containment integrity. To study its feasibility and to optimize the design, multi-dimensional containment modelling may be required. This paper presents a comparison of two CFD codes, GOTHIC and PHOENICS, for multi-dimensional containment analysis and gives pressure transient predictions from a lumped-parameter and a three-dimensional GOTHIC model for a modified CANDU-3 containment. GOTHIC proved suitable for multidimensional post-accident containment analysis, as shown by the good agreement with pressure transient predictions from PHOENICS. GOTHIC is, therefore, recommended for passive CANDU containment modelling. (author)

  10. Analytical optimization of interior PCM for energy storage in a lightweight passive solar room

    International Nuclear Information System (INIS)

    Xiao Wei; Wang Xin; Zhang Yinping

    2009-01-01

    Lightweight envelopes are widely used in modern buildings but they lack sufficient thermal capacity for passive solar utilization. An attractive solution to increase the building thermal capacity is to incorporate phase change material (PCM) into the building envelope. In this paper, a simplified theoretical model is established to optimize an interior PCM for energy storage in a lightweight passive solar room. Analytical equations are presented to calculate the optimal phase change temperature and the total amount of latent heat capacity and to estimate the benefit of the interior PCM for energy storage. Further, as an example, the analytical optimization is applied to the interior PCM panels in a direct-gain room with realistic outdoor climatic conditions of Beijing. The analytical results agree well with the numerical results. The analytical results show that: (1) the optimal phase change temperature depends on the average indoor air temperature and the radiation absorbed by the PCM panels; (2) the interior PCM has little effect on average indoor air temperature; and (3) the amplitude of the indoor air temperature fluctuation depends on the product of surface heat transfer coefficient h in and area A of the PCM panels in a lightweight passive solar room.

  11. Design and analysis of a new passive residual heat removal system

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Xing [Key Subject Laboratory of Nuclear Safety and Simulation Technology, Harbin Engineering University, Harbin, Heilongjiang 150001 (China); Peng, Minjun, E-mail: heupmj@163.com [Key Subject Laboratory of Nuclear Safety and Simulation Technology, Harbin Engineering University, Harbin, Heilongjiang 150001 (China); Yuan, Xiao [Guangxi Fangchenggang Nuclear Power Co., Ltd (China); Xia, Genglei [Key Subject Laboratory of Nuclear Safety and Simulation Technology, Harbin Engineering University, Harbin, Heilongjiang 150001 (China)

    2016-07-15

    Highlights: • An air cooling passive residual heat removal System (PRHRs) is designed. • Using RELAP5/MOD3.4 code to analyze the operation characteristics of the PRHRs. • Noncondensable gas is used to simulate the hydrodynamic behavior in the air cooling tower. • The natural circulations could respectively establish in the primary circuit and the PRHRs circuit. • The PRHRs could remove the residual heat effectively. - Abstract: The inherent safety functions will mitigate the consequences of the accidents, and it can be accomplished through the passive safety systems which employed in the typical pressurized water reactor (PWR). In this paper, a new passive residual heat removal system (PRHRS) is designed for a typical nuclear power plant. PRHRS consists of a steam generator (SG), a cooling tank with two groups of cooling pipes, an air-cooling heat exchanger (AHX), an air-cooling tower, corresponding pipes and valves. The cooling tank which works as an intermediate buffer device is used to transfer the core decay heat to the AHX, and then the core decay heat will be removed to the atmosphere finally. The RELAP5/MOD3.4 code is used to analyze the operation characteristics of PRHRS and the primary loop system. It shows PRHRS could remove the decay heat from the primary loop effectively, and the natural circulations can be established in the primary circuit and the PRHRS circuit respectively. Furthermore, the sensitivity study has also been done to research the effect of various factors on the heat removal capacity.

  12. Passive ventilation systems with heat recovery and night cooling

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2008-01-01

    with little energy consumption and with satisfying indoor climate. The concept is based on using passive measures like stack and wind driven ventilation, effective night cooling and low pressure loss heat recovery using two fluid coupled water-to-air heat exchangers developed at the Technical University...... simulation program ESP-r to model the heat and air flows and the results show the feasibility of the proposed ventilation concept in terms of low energy consumption and good indoor climate....

  13. Evaporation and condensation devices for passive heat removal systems in nuclear power engineering

    International Nuclear Information System (INIS)

    Gershuni, A.N.; Pis'mennyj, E.N.; Nishchik, A.P.

    2016-01-01

    The paper justifies advantages of evaporation and condensation heat transfer devices as means of passive heat removal and thermal shielding in nuclear power engineering. The main thermophysical factors that limit heat transfer capacity of evaporation and condensation systems have been examined in the research. The results of experimental studies of heat engineering properties of elongated (8-m) vertically oriented evaporation and condensation devices (two-phase thermosyphons), which showed a high enough heat transfer capacity, as well as stability and reliability both in steady state and in start-up modes, are provided. The paper presents the examples of schematic designs of evaporation and condensation systems for passive heat removal and thermal shielding in application to nuclear power equipment

  14. Effect of short-term exercise-heat acclimation on ventilatory and cerebral blood flow responses to passive heating at rest in humans.

    Science.gov (United States)

    Fujii, Naoto; Tsuji, Bun; Honda, Yasushi; Kondo, Narihiko; Nishiyasu, Takeshi

    2015-09-01

    Hyperthermia induces hyperventilation and cerebral hypoperfusion in resting humans. We tested the hypothesis that short-term exercise-heat acclimation would alleviate those effects. Twenty healthy male subjects were divided into two groups that performed exercise training in the heat (TR-HEAT, n = 10) or cold (TR-COLD, n = 10). Before and after the training, the subjects in both groups participated in passive-heat tests at rest. Training was performed at 37°C (TR-HEAT) or 10°C (TR-COLD) and entailed four 20-min bouts of cycling at 50% peak oxygen uptake separated by 10-min recoveries daily for 6 consecutive days. After TR-HEAT, esophageal temperature was lowered when measured before and during passive heating, as was the esophageal temperature threshold for cutaneous active vasodilation, whereas plasma volume was increased (all P heat acclimation were not all induced by TR-COLD (all P > 0.05). TR-HEAT had no significant effect on passive heating-induced increases in minute ventilation, even when evaluated as the esophageal temperature threshold for increases in minute ventilation and the slope relating minute ventilation to esophageal temperature (all P > 0.05). By contrast, TR-HEAT attenuated the passive heating-induced reduction in the cerebral vascular conductance index (middle cerebral artery mean blood velocity/mean arterial pressure) (all P heating (all P > 0.05). These data suggest that in resting heated humans, short-term heat acclimation achieved through moderate-intensity exercise training (i.e., 50% peak oxygen uptake) in the heat does not influence hyperthermia-induced hyperventilation, but it does potentially attenuate cerebral hypoperfusion. Copyright © 2015 the American Physiological Society.

  15. Columbia County Habitat for Humanity Passive Townhomes

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [The Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Alaigh, Kunal [The Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Dadia, Devanshi [The Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States)

    2016-03-18

    Columbia County (New York) Habitat for Humanity built a pair of townhomes to Passive House criteria with the purpose of exploring approaches for achieving Passive House performance and to eventually develop a prototype design for future projects. The project utilized a 2x6 frame wall with a structural insulated panel curtain wall and a ventilated attic over a sealed OSB ceiling air barrier. Mechanical systems include a single head, wall mounted ductless mini-split heat pump in each unit and a heat recovery ventilator. Costs were $26,000 per unit higher for Passive House construction compared with the same home built to ENERGY STAR version 3 specifications, representing about 18% of total construction cost. This report discusses the cost components, energy modeling results and lessons from construction. Two alternative ventilation systems are analyzed: a central system; and, a point-source system with small through-wall units distributed throughout the house. The report includes a design and cost analysis of these two approaches.

  16. Solar Panels reduce both global warming and Urban Heat Island

    Directory of Open Access Journals (Sweden)

    Valéry eMasson

    2014-06-01

    Full Text Available The production of solar energy in cities is clearly a way to diminish our dependency to fossil fuels, and is a good way to mitigate global warming by lowering the emission of greenhouse gases. However, what are the impacts of solar panels locally ? To evaluate their influence on urban weather, it is necessary to parameterize their effects within the surface schemes that are coupled to atmospheric models. The present paper presents a way to implement solar panels in the Town Energy Balance scheme, taking account of the energy production (for thermal and photovoltaic panels, the impact on the building below and feedback towards the urban micro-climate through radiative and convective fluxes. A scenario of large but realistic deployment of solar panels on the Paris metropolitan area is then simulated. It is shown that solar panels, by shading the roofs, slightly increases the need for domestic heating (3%. In summer however, the solar panels reduce the energy needed for air-conditioning (by 12% and also the Urban Heat Island (UHI: 0.2K by day and up to 0.3K at night. These impacts are larger than those found in previous works, because of the use of thermal panels (that are more efficient than photovoltaic panels and the geographical position of Paris, which is relatively far from the sea. This means that it is not influenced by sea breezes, and hence that its UHI is stronger than for a coastal city of the same size. But this also means that local adaptation strategies aiming to decrease the UHI will have more potent effects. In summary, the deployment of solar panels is good both globally, to produce renewable energy (and hence to limit the warming of the climate and locally, to decrease the UHI, especially in summer, when it can constitute a health threat.

  17. Experimental study on heat pipe heat removal capacity for passive cooling of spent fuel pool

    International Nuclear Information System (INIS)

    Xiong, Zhenqin; Wang, Minglu; Gu, Hanyang; Ye, Cheng

    2015-01-01

    Highlights: • A passively cooling SFP heat pipe with an 8.2 m high evaporator was tested. • Heat removed by the heat pipe is in the range of 3.1–16.8 kW. • The heat transfer coefficient of the evaporator is 214–414 W/m 2 /K. • The heat pipe performance is sensitive to the hot water temperature. - Abstract: A loop-type heat pipe system uses natural flow with no electrically driven components. Therefore, such a system was proposed to passively cool spent fuel pools during accidents to improve nuclear power station safety especially for station blackouts such as those in Fukushima. The heat pipe used for a spent fuel pool is large due to the spent fuel pool size. An experimental heat pipe test loop was developed to estimate its heat removal capacity from the spent fuel pool during an accident. The 7.6 m high evaporator is heated by hot water flowing vertically down in an assistant tube with a 207-mm inner diameter. R134a was used as the potential heat pipe working fluid. The liquid R134a level was 3.6 m. The tests were performed for water velocities from 0.7 to 2.1 × 10 −2 m/s with water temperatures from 50 to 90 °C and air velocities from 0.5 m/s to 2.5 m/s. The results indicate significant heat is removed by the heat pipe under conditions that may occur in the spent fuel pool

  18. Condensation heat transfer with noncondensable gas for passive containment cooling of nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Leonardi, Tauna [Schlumberger, 14910 Airline Rd., Rosharon, TX 77583 (United States)]. E-mail: Tleonardi@slb.com; Ishii, Mamoru [School of Nuclear Engineering, Purdue University, West Lafayette, IN 47907 (United States)]. E-mail: Ishii@ecn.purdue.edu

    2006-09-15

    Noncondensable gases that come from the containment and the interaction of cladding and steam during a severe accident deteriorate a passive containment cooling system's performance by degrading the heat transfer capabilities of the condensers in passive containment cooling systems. This work contributes to the area of modeling condensation heat transfer with noncondensable gases in integral facilities. Previously existing correlations and models are for the through-flow of the mixture of steam and the noncondensable gases and this may not be applicable to passive containment cooling systems where there is no clear passage for the steam to escape. This work presents a condensation heat transfer model for the downward cocurrent flow of a steam/air mixture through a condenser tube, taking into account the atypical characteristics of the passive containment cooling system. An empirical model is developed that depends on the inlet conditions, including the mixture Reynolds number and noncondensable gas concentration.

  19. Supplementary material on passive solar heating concepts. A compilation of published articles

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-05-01

    A compilation of published articles and reports dealing with passive solar energy concepts for heating and cooling buildings is presented. The following are included: fundamental of passive systems, applications and technical analysis, graphic tools, and information sources. (MHR)

  20. A passive cooling system proposal for multifunction and high-power displays

    Science.gov (United States)

    Tari, Ilker

    2013-03-01

    Flat panel displays are conventionally cooled by internal natural convection, which constrains the possible rate of heat transfer from the panel. On one hand, during the last few years, the power consumption and the related cooling requirement for 1080p displays have decreased mostly due to energy savings by the switch to LED backlighting and more efficient electronics. However, on the other hand, the required cooling rate recently started to increase with new directions in the industry such as 3D displays, and ultra-high-resolution displays (recent 4K announcements and planned introduction of 8K). In addition to these trends in display technology itself, there is also a trend to integrate consumer entertainment products into displays with the ultimate goal of designing a multifunction device replacing the TV, the media player, the PC, the game console and the sound system. Considering the increasing power requirement for higher fidelity in video processing, these multifunction devices tend to generate very high heat fluxes, which are impossible to dissipate with internal natural convection. In order to overcome this obstacle, instead of active cooling with forced convection that comes with drawbacks of noise, additional power consumption, and reduced reliability, a passive cooling system relying on external natural convection and radiation is proposed here. The proposed cooling system consists of a heat spreader flat heat pipe and aluminum plate-finned heat sink with anodized surfaces. For this system, the possible maximum heat dissipation rates from the standard size panels (in 26-70 inch range) are estimated by using our recently obtained heat transfer correlations for the natural convection from aluminum plate-finned heat sinks together with the surface-to-surface radiation. With the use of the proposed passive cooling system, the possibility of dissipating very high heat rates is demonstrated, hinting a promising green alternative to active cooling.

  1. Development and testing of passive autocatalytic recombiners cooled by heat pipes

    International Nuclear Information System (INIS)

    Granzow, Christoph

    2012-01-01

    A severe accident in a nuclear power plant (NPP) can lead to core damage in conjunction with the release of large amounts of hydrogen. As hydrogen mitigation measure, passive autocatalytic recombiners (PARs) are used in today's pressurized water reactors. PARs recombine hydrogen and oxygen contained in the air to steam. The heat from this exothermic reaction causes the catalyst and its surroundings to heat up. If parts of the PAR heat up above the ignition temperature of the gas mixture, a spontaneous deflagration or detonation can occur. The aim of this work is the prevention of such high temperatures by means of passive cooling of the catalyst with heat pipes. Heat pipes are completely passive heat exchanger with a very high effective thermal conductivity. For a deeper understanding of the reaction kinetics at lower temperatures, single catalytic coated heat pipes are studied in a flow reactor. The development of a modular small-scale PAR model is then based on a test series with cooled catalyst sheets. Finally, the PAR model is tested inside a pressure vessel under boundary conditions similar to a real NPP. The experiments show, that the temperatures of the cooled catalytic sheets stay significantly below the temperature of the uncooled sheets and below the ignition temperature of the gas mixture under any set boundary conditions, although no significant reduction of the conversion efficiency can be observed. As a last point, a mathematical model of the reaction kinetics of the recombination process as well as a model of the fluid dynamic and thermohydraulic processes in a heat pipe are developed with the data obtained from the experiments.

  2. Influence of the ventilation system on thermal comfort of the chilled panel system in heating mode

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Zhe; Ding, Yan; Wang, Shuo; Yin, Xinglei; Wang, Menglei [Tianjin University, Tianjin 300072 (China)

    2010-12-15

    In heating mode, fresh air is still essential for a chilled panel system in order to ensure the indoor air quality. In this paper, a chilled ceiling panel system was designed and built in a typical office room. The thermal environment and thermal comfort in the room were fully measured and evaluated by using the Fanger's PMV-PPD model and the standard of ISO 7730 respectively, when room was heated in two modes, one of which is the chilled panel heating mode and the other of which is the combined heating mode of chilled panel and supply air. The research results indicate that in the combined mode, ceiling ventilation improves the general thermal comfort and reduces the risk of local discomfort. Under the condition of same general thermal comfort, the heating supply upper limit of chilled panel can be increased by 12.3% because of air mixing effect caused by introduction of air ventilation. (author)

  3. A passive emergency heat sink for water-cooled reactors with particular application to CANDU reactors

    International Nuclear Information System (INIS)

    Spinks, N.J.

    1996-01-01

    Water in an overhead pool can serve as a general-purpose passive emergency heat sink for water-cooled reactors. It can be used for containment cooling, for emergency depressurization of the heat transport-system, or to receive any other emergency heat, such as that from the CANDU moderator. The passive emergency water system provides in-containment depressurization of steam generators and no other provision is needed for supply of low-pressure emergency water to the steam generators. For containment cooling, the pool supplies water to the tube side of elevated tube banks inside containment. The elevation with respect to the reactor heat source maximizes heat transport, by natural convection, of hot containment gases. This effective heat transport combines with the large heat-transfer coefficients of tube banks, to reduce containment overpressure during accidents. Cooled air from the tube banks is directed past the break in the heat-transport system, to facilitate removal of hydrogen using passive catalytic recombiners. (author)

  4. Effect of passive heat stress on arterial stiffness in smokers versus non-smokers

    Science.gov (United States)

    Moyen, N. E.; Ganio, M. S.; Burchfield, J. M.; Tucker, M. A.; Gonzalez, M. A.; Dougherty, E. K.; Robinson, F. B.; Ridings, C. B.; Veilleux, J. C.

    2016-04-01

    In non-smokers, passive heat stress increases shear stress and vasodilation, decreasing arterial stiffness. Smokers, who reportedly have arterial dysfunction, may have similar improvements in arterial stiffness with passive heat stress. Therefore, we examined the effects of an acute bout of whole-body passive heat stress on arterial stiffness in smokers vs. non-smokers. Thirteen smokers (8.8 ± 5.5 [median = 6] cigarettes per day for >4 years) and 13 non-smokers matched for age, mass, height, and exercise habits (27 ± 8 years; 78.8 ± 15.4 kg; 177.6 ± 6.7 cm) were passively heated to 1.5 °C core temperature ( T C) increase. At baseline and each 0.5 °C T C increase, peripheral (pPWV) and central pulse wave velocity (cPWV) were measured via Doppler ultrasound. No differences existed between smokers and non-smokers for any variables (all p > 0.05), except cPWV slightly increased from baseline (526.7 ± 81.7 cm · s-1) to 1.5 °C Δ T C (579.7 ± 69.8 cm · s-1; p 0.05). Changes in cPWV and pPWV during heating correlated ( p smokers (cPWV: r = -0.59; pPWV: r = -0.62) and non-smokers (cPWV: r = -0.45; pPWV: r = -0.77). Independent of smoking status, baseline stiffness appears to mediate the magnitude of heating-induced changes in arterial stiffness.

  5. Shape Morphing Adaptive Radiator Technology (SMART) for Variable Heat Rejection

    Science.gov (United States)

    Erickson, Lisa

    2016-01-01

    The proposed technology leverages the temperature dependent phase change of shape memory alloys (SMAs) to drive the shape of a flexible radiator panel. The opening/closing of the radiator panel, as a function of temperature, passively adapts the radiator's rate of heat rejection in response to a vehicle's needs.

  6. Dynamic heat transfer modeling and parametric study of thermoelectric radiant cooling and heating panel system

    International Nuclear Information System (INIS)

    Luo, Yongqiang; Zhang, Ling; Liu, Zhongbing; Wang, Yingzi; Wu, Jing; Wang, Xiliang

    2016-01-01

    Highlights: • Dynamic model of thermoelectric radiant panel system is established. • The internal parameters of thermoelectric module are dynamically calculated in simulation. • Both artificial neural networks model and system model are verified through experiment data. • Optimized system structure is obtained through parametric study. - Abstract: Radiant panel system can optimize indoor thermal comfort with lower energy consumption. The thermoelectric radiant panel (TERP) system is a new and effective prototype of radiant system using thermoelectric module (TEM) instead of conventional water pipes, as heat source. The TERP can realize more stable and easier system control as well as lower initial and operative cost. In this study, an improved system dynamic model was established by combining analytical system model and artificial neural networks (ANN) as well as the dynamic calculation functions of internal parameters of TEM. The double integral was used for the calculation of surface average temperature of TERP. The ANN model and system model were in good agreement with experiment data in both cooling and heating mode. In order to optimize the system design structure, parametric study was conducted in terms of the thickness of aluminum panel and insulation, as well as the arrangement of TEMs on the surface of radiant panel. It was found through simulation results that the optimum thickness of aluminum panel and insulation are respectively around 1–2 mm and 40–50 mm. In addition, TEMs should be uniformly installed on the surface of radiant panel and each TEM should stand at the central position of a square-shaped typical region with length around 0.387–0.548 m.

  7. Compact flat-panel gas-gap heat switch operating at 295 K

    Science.gov (United States)

    Krielaart, M. A. R.; Vermeer, C. H.; Vanapalli, S.

    2015-11-01

    Heat switches are devices that can change from a thermally conducting (on-) state to an insulating (off-) state whenever the need arises. They enable adaptive thermal management strategies in which cooling rates are altered either spatially or temporally, leading to a substantial reduction in the energy and mass budget of a large range of systems. State-of-the-art heat switches are only rarely employed in thermal system architectures, since they are rather bulky and have a limited thermal performance (expressed as the heat transfer ratio between the on- and off-state heat conductance). Using selective laser melting additive manufacturing technology, also known as 3D printing, we developed a compact flat-panel gas-gap heat switch that offers superior thermal performance, is simpler and more economic to produce and assemble, contains no moving parts, and is more reliable because it lacks welded joints. The manufactured rectangular panel heat switch has frontal device dimensions of 10 cm by 10 cm, thickness of 3.2 mm and weighs just 121 g. An off heat conductance of 0.2 W/K and on-off heat conductance ratio of 38 is observed at 295 K.

  8. Photovoltaic cell electrical heating system for removing snow on panel including verification.

    Science.gov (United States)

    Weiss, Agnes; Weiss, Helmut

    2017-11-16

    Small photovoltaic plants in private ownership are typically rated at 5 kW (peak). The panels are mounted on roofs at a decline angle of 20° to 45°. In winter time, a dense layer of snow at a width of e.g., 10 cm keeps off solar radiation from the photovoltaic cells for weeks under continental climate conditions. Practically, no energy is produced over the time of snow coverage. Only until outside air temperature has risen high enough for a rather long-time interval to allow partial melting of snow; the snow layer rushes down in an avalanche. Following this proposal, snow removal can be arranged electrically at an extremely positive energy balance in a fast way. A photovoltaic cell is a large junction area diode inside with a threshold voltage of about 0.6 to 0.7 V (depending on temperature). This forward voltage drop created by an externally driven current through the modules can be efficiently used to provide well-distributed heat dissipation at the cell and further on at the glass surface of the whole panel. The adhesion of snow on glass is widely reduced through this heating in case a thin water film can be produced by this external short time heating. Laboratory experiments provided a temperature increase through rated panel current of more than 10 °C within about 10 min. This heating can initiate the avalanche for snow removal on intention as described before provided the clamping effect on snow at the edge of the panel frame is overcome by an additional heating foil. Basics of internal cell heat production, heating thermal effects in time course, thermographic measurements on temperature distribution, power circuit opportunities including battery storage elements and snow-removal under practical conditions are described.

  9. Use of Polyurethane Insulated Panel for Heat Infiltration in ...

    African Journals Online (AJOL)

    ADOWIE PERE

    ABSTRACT: This study investigates the overall heat transfer coefficient of reinforced composite panel ... K thermal conductivity value W/m2k ... fabricated from epoxy resin and E-glass fibre and the ... Table 1: Parameters used in calculation.

  10. Passive cryogenic cooling of electrooptics with a heat pipe/radiator.

    Science.gov (United States)

    Nelson, B E; Goldstein, G A

    1974-09-01

    The current status of the heat pipe is discussed with particular emphasis on applications to cryogenic thermal control. The competitive nature of the passive heat pipe/radiator system is demonstrated through a comparative study with other candidate systems for a 1-yr mission. The mission involves cooling a spaceborne experiment to 100 K while it dissipates 10 W.

  11. Impairment of Heat Transfer in the Passive Cooling System due to Mixed Convection

    Energy Technology Data Exchange (ETDEWEB)

    Chae Myeong Seon; Chung, Bum Jin [Kyunghee University, Yongin (Korea, Republic of); Kim, Jong Hwan [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In the passive cooling devices, the buoyant flows are induced. However the local Nusselt number of natural convective flow can be partly impaired due to the development of the mixed convective flows. This paper discusses impairment of heat transfer in the passive cooling system in relation to the development of mixed convection. The present work describes the preliminary plan to explore the phenomena experimentally. This paper is to discuss and make the plan to experiment the impairment of heat transfer in the passive cooling system due to mixed convection. In the sufficiently high passive cooling devices, the natural convection flow behavior can be mixed convection. The local Nusselt number distribution exhibits the non-monotonic behavior as axial position, since the buoyancy-aided with mixed convection was appeared. This is the part of the experimental work.

  12. Reliability analysis on passive residual heat removal of AP1000 based on Grey model

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Shi; Zhou, Tao; Shahzad, Muhammad Ali; Li, Yu [North China Electric Power Univ., Beijing (China). School of Nuclear Science and Engineering; Beijing Key Laboratory of Passive Safety Technology for Nuclear Energy, Beijing (China); Jiang, Guangming [Nuclear Power Institute of China, Chengdu (China). Science and Technology on Reactor System Design Technology Laboratory

    2017-06-15

    It is common to base the design of passive systems on the natural laws of physics, such as gravity, heat conduction, inertia. For AP1000, a generation-III reactor, such systems have an inherent safety associated with them due to the simplicity of their structures. However, there is a fairly large amount of uncertainty in the operating conditions of these passive safety systems. In some cases, a small deviation in the design or operating conditions can affect the function of the system. The reliability of the passive residual heat removal is analysed.

  13. Thermal energy storage in the form of heat or cold with using of the PCM-based accumulation panels

    Directory of Open Access Journals (Sweden)

    Skovajsa Jan

    2016-01-01

    Full Text Available This article describes the usage of thermal energy storage in the form of heat and cold with an adaptation of the special device which is composed of the thermal panels. These panels are based on the phase change materials (PCM for normal inner environment temperature in buildings. The energy for the thermal energy storage is possible to get from built-in electric heating foil or from the tube heat exchanger, which is build in the thermal panels. This technology is able to use renewable energy sources, for example, solar thermal collectors and air-to-water heat pump as a source of heat for heating of the hot water tank. In the cooling mode, there is able to use the heat pump or photovoltaics panels in combination with thermoelectric coolers for cooling.

  14. Simplified analysis of passive residual heat removal systems for small size PWR's

    International Nuclear Information System (INIS)

    Botelho, D.A.

    1992-02-01

    The function and general objectives of a passive residual heat removal system for small size PWR's are defined. The characteristic configuration, the components and the operation modes of this system are concisely described. A preliminary conceptual specification of this system, for a small size PWR of 400 MW thermal, is made analogous to the decay heat removal system of the AP-600 reactor. It is shown by analytic models that such passive systems can dissipate 2% of nominal power within the thermal limits allowed to the reactor fuel elements. (author)

  15. Passive decay heat removal by natural circulation

    International Nuclear Information System (INIS)

    Vijayan, P.K.; Venkat Raj, V.; Kakodkar, A.; Mehta, S.K.

    1990-01-01

    The standardised 235 MWe PHWRs being built in India are the pressure tube type, heavy water moderated, heavy water cooled and natural uranium fuelled reactors. Several passive safety features are incorporated in these reactors. These include: (1) Containment pressure reduction and fission product trapping with the help of suppression pool following LOCA. (2) Emergency coolant injection by means of accumulators. (3) Large heat sink provided by the low temperature moderator under accident conditions. (4) Low excess reactivity, through the use of natural uranium fuel and on power fuelling. (5) Residual heat removal by means of natural circulation, etc. of which the last item is the subject matter of this report. (author). 8 refs, 10 figs

  16. Phase Change Material Based Accumulation Panels in Combination with Renewable Energy Sources and Thermoelectric Cooling

    Directory of Open Access Journals (Sweden)

    Jan Skovajsa

    2017-01-01

    Full Text Available The article deals with the use of modern materials and technologies that can improve the thermal comfort in buildings. The article describes the design and usage of a special accumulation device, which is composed of thermal panels based on phase change materials (PCMs. The thermal panels have an integrated tube heat exchanger and heating foils. The technology can be used as a passive or active system for heating and cooling. It is designed as a “green technology”, so it is able to use renewable energy sources, e.g., photovoltaic (PV panels, solar thermal collectors and heat pumps. Moreover, an interesting possibility is the ability to use thermoelectric coolers. In the research, measurements of the different operating modes were made, and the results are presented in the text. The measurement approves that the technology improves the thermal capacity of the building, and it is possible to use it for active heating and cooling.

  17. Turbulence convective heat transfer for cooling the photovoltaic cells

    Science.gov (United States)

    Arianmehr, Iman

    Solar PV (photovoltaic) is a rapidly advancing renewable energy technology which converts sunlight directly into electricity. One of the outstanding challenges of the current PV technology is the reduction in its conversion efficiency with increasing PV panel temperature, which is closely associated with the increase in solar intensity and the ambient temperature surrounding the PV panels. To more effectively capture the available energy when the sun is most intense, significant efforts have been invested in active and passive cooling research over the last few years. While integrated cooling systems can lead to the highest total efficiencies, they are usually neither the most feasible nor the most cost effective solutions. This work examines some simple passive means of manipulating the prevailing wind turbulence to enhance convective heat transfer over a heated plate in a wind tunnel.

  18. Experimental and analytical studies of a passive shutdown heat removal system for advanced LMRs

    International Nuclear Information System (INIS)

    Heineman, J.; Kraimer, M.; Lottes, P.; Pedersen, D.; Stewart, R.; Tessier, J.

    1988-01-01

    A facility designed and constructed to demonstrate the viability of natural convection passive heat removal systems as a key feature of innovative LMR Shutdown Heat Removal (SHR) systems is in operation at Argonne National Laboratory (ANL). This Natural Convection Shutdown Heat Removal Test Facility (NSTF) is being used to investigate the heat transfer performance of the GE/PRISM and the RI/SAFR passive designs. This paper presents a description of the NSTF, the pretest analysis of the Radiant Reactor Vessel Auxiliary Cooling System (RVACS) in support of the GE/PRISM IFR concept, and experiment results for the RVACS simulation. Preliminary results show excellent agreement with predicted system performance

  19. Experimental and analytical studies of a passive shutdown heat removal system for advanced LMRs

    Energy Technology Data Exchange (ETDEWEB)

    Heineman, J.; Kraimer, M.; Lottes, P.; Pedersen, D.; Stewart, R.; Tessier, J.

    1988-01-01

    A facility designed and constructed to demonstrate the viability of natural convection passive heat removal systems as a key feature of innovative LMR Shutdown Heat Removal (SHR) systems is in operation at Argonne National Laboratory (ANL). This Natural Convection Shutdown Heat Removal Test Facility (NSTF) is being used to investigate the heat transfer performance of the GE/PRISM and the RI/SAFR passive designs. This paper presents a description of the NSTF, the pretest analysis of the Radiant Reactor Vessel Auxiliary Cooling System (RVACS) in support of the GE/PRISM IFR concept, and experiment results for the RVACS simulation. Preliminary results show excellent agreement with predicted system performance.

  20. Heat transfer performance of heat pipe for passive cooling of spent fuel pool

    International Nuclear Information System (INIS)

    Wang Minglu; Xiong Zhengqin; Gu Hanyang; Ye Cheng; Cheng Xu

    2014-01-01

    A large-scale loop heat pipe has no electricity driven component and high efficiency of heat transfer. It can be used for the passive cooling of the SFP after SBO to improve the safety performance of nuclear power plants. In this paper, such a large-scale loop heat pipe is studied experimentally. The heat transfer rate, evaporator average heat transfer coefficient operating temperature, operating pressure and ammonia flow rate have been obtained with the water flow ranging from 0.007 m/s to 0.02 m/s outside the evaporator section, heating water temperature in the range of 50 to 90℃, air velocity outside the condensation section ranging from 0.5 to 2.5 m/s. It is found that the heat transfer rate reaches as high as 20.1 kW. Parametric analysis indicates that, the heat transfer rate and ammonia flow rate are influenced significantly by hot water inlet temperature and velocity, while beyond 1.5 m/s, the effect of air velocity outside the condensation section is minor. (authors)

  1. No effects of acclimation to heat on immune and hormonal responses to passive heating in healthy volunteers

    Science.gov (United States)

    Kanikowska, Dominika; Sato, Maki; Sugenoya, Junichi; Iwase, Satoshi; Shimizu, Yuuki; Nishimura, Naoki; Inukai, Yoko

    2012-01-01

    Heat acclimation results in whole body-adaptations that increase heat tolerance, and might also result in changed immune responses. We hypothesized that, after heat acclimation, tumor necrosis factor alpha, interleukin 6 and the lymphocyte count would be altered. Heat acclimation was induced in 6 healthy men by 100 min of heat exposure for 9 days. Heat exposure consisted of (1) 10 min of immersion up to chest-level in water at 42°C and (2) 90 min of passive heating by a warm blanket to maintain tympanic temperature at 37.5°C. The climatic chamber was maintained at 40°C and a relative humidity of 50%. Blood samples were analyzed before and after heat acclimation for natural killer (NK) cell activity, counts of lymphocytes B and T, before and after heat acclimation for peripheral blood morphology, interleukin 6, tumor necrosis factor alpha, and cortisol. A Japanese version of the profile of mood states questionnaire was also administered before and after acclimation. The concentrations of white blood cells, lymphocytes B and T, cortisol, interleukin 6, tumor necrosis factor alpha and NK cell activity showed no significant differences between pre- and post-acclimation, but there was a significantly lower platelet count after acclimation and, with the profile of mood states questionnaire, there was a significant rise in anger after acclimation. It is concluded that heat acclimation by passive heating does not induce alterations in immune or endocrine responses.

  2. Passive Heat Exposure Alters Perception and Executive Function

    Directory of Open Access Journals (Sweden)

    Rachel A. Malcolm

    2018-05-01

    Full Text Available Findings regarding the influence of passive heat exposure on cognitive function remain equivocal due to a number of methodological issues including variation in the domains of cognition examined. In a randomized crossover design, forty-one male participants completed a battery of cognitive function tests [Visual Search, Stroop, Corsi Blocks and Rapid Visual Information Processing (RVIP tests] prior to and following 1 h of passive rest in either hot (39.6 ± 0.4°C, 50.8 ± 2.3% Rh or moderate (21.2 ± 1.8°C, 41.9 ± 11.4% Rh conditions. Subjective feelings of heat exposure, arousal and feeling were assessed alongside physiological measures including core temperature, skin temperature and heart rate, at baseline and throughout the protocol. Response times were slower in the hot trial on the simple (main effect of trial, P < 0.001 and complex (main effect of trial, P < 0.001 levels of the Stroop test (Hot: 872 ± 198 ms; Moderate: 834 ± 177 ms and the simple level of the visual search test (Hot: 354 ± 54 ms; Moderate: 331 ± 47 ms (main effect of trial, P < 0.001. Participants demonstrated superior accuracy on the simple level of the Visual Search test in the hot trial (Hot: 98.5 ± 3.1%; Moderate: 97.4 ± 3.6% (main effect of trial, P = 0.035. Participants also demonstrated an improvement in accuracy on the complex level of the visual search test following 1 h passive heat exposure (Pre: 96.8 ± 5.9%; Post: 98.1 ± 3.1%, whilst a decrement was seen across the trial in the moderate condition (Pre: 97.7 ± 3.5; Post: 97.0 ± 5.1% (time*trial interaction, P = 0.029. No differences in performance were observed on the RVIP or Corsi Blocks tests (all P > 0.05. Subjective feelings of thermal sensation and felt arousal were higher, feeling was lower in the hot trial, whilst skin temperature, core temperature and heart rate were higher (main effects of trial, all P < 0.001. The findings of the present study suggest that response times for perception

  3. Passive ventilation systems with heat recovery and night cooling

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2008-01-01

    with little energy consumption and with satisfying indoor climate. The concept is based on using passive measures like stack and wind driven ventilation, effective night cooling and low pressure loss heat recovery using two fluid coupled water-to-air heat exchangers developed at the Technical University......In building design the requirements for energy consumption for ventilation, heating and cooling and the requirements for increasingly better indoor climate are two opposing factors. This paper presents the schematic layout and simulation results of an innovative multifunc-tional ventilation concept...... of Denmark. Through building integration in high performance offices the system is optimized to incorporate multiple functions like heating, cooling and ventilation, thus saving the expenses of separate cooling and heating systems. The simulation results are derived using the state-of-the-art building...

  4. Detection of insulation flaws and thermal bridges in insulated truck box panels

    OpenAIRE

    Lei, Lei; Bortolin, Alessandro; Bison, Paolo ©; Maldague, X.

    2017-01-01

    This paper focuses on the detection of defects and thermal bridges in insulated truck box panels, utilising infrared thermography. Unlike the traditional way in which passive thermography is applied, this research uses both heating and cooling methods in active thermography configurations. Lamp heating is used as the hot external stimulation, while a compressed air jet is applied as the cold external stimulation. A thermal camera captures the whole process. In addition, numerical simulations ...

  5. Correlation analysis of heat flux and fire behaviour and hazards of polycrystalline silicon photovoltaic panels

    Science.gov (United States)

    Ju, Xiaoyu; Zhou, Xiaodong; Peng, Fei; Wu, Zhibo; Lai, Dimeng; Hu, Yue; Yang, Lizhong

    2017-05-01

    This work aims to gain a better understanding of fire behaviour and hazards of PV panels under different radiation heat fluxes. The cone calorimeter tests were applied to simulate the situations when the front and back surfaces are exposed to heat flux in a fire, respectively. Through comparison of ignition time, mass loss rate and heat release rate, it is found that the back-up condition is more hazardous than face-up condition. Meanwhile, three key parameters: flashover propensity, total heat release and FED, were introduced to quantitatively illustrate fire hazards of a PV panel.

  6. STEADY-STATE HEAT REJECTION RATES FOR A COAXIAL BOREHOLE HEAT EXCHANGER DURING PASSIVE AND ACTIVE COOLING DETERMINED WITH THE NOVEL STEP THERMAL RESPONSE TEST METHOD

    Directory of Open Access Journals (Sweden)

    Marija Macenić

    2018-01-01

    Full Text Available At three locations in Zagreb, classical and extended thermal response test (TRT was conducted on installed coaxial heat exchangers. With classic TR test, thermogeological properties of the ground and thermal resistance of the borehole were determined at each location. It is seen that thermal conductivity of the ground varies, due to difference in geological profile of the sites. In addition, experimental research of steady-state thermal response step test (SSTRST was carried out to determine heat rejection rates for passive and active cooling in steady state regime. Results showed that heat rejection rate is only between 8-11 W/m, which indicates that coaxial system is not suitable for passive cooling demands. Furthermore, the heat pump in passive cooling mode uses additional plate heat exchanger where there is additional temperature drop of working fluid by approximately 1,5 °C. Therefore, steady-state rejection rate for passive cooling is even lower for a real case project. Coaxial heat exchanger should be always designed for an active cooling regime with an operation of a heat pump compressor in a classical vapour compression refrigeration cycle.

  7. Confirmatory analysis of the AP1000 passive residual heat removal heat exchanger with 3-D computational fluid dynamic analysis

    International Nuclear Information System (INIS)

    Schwall, James R.; Karim, Naeem U.; Thakkar, Jivan G.; Taylor, Creed; Schulz, Terry; Wright, Richard F.

    2006-01-01

    The AP1000 is an 1100 MWe advanced nuclear power plant that uses passive safety features to enhance plant safety and to provide significant and measurable improvements in plant simplification, reliability, investment protection and plant costs. The AP1000 received final design approval from the US-NRC in 2004. The AP1000 design is based on the AP600 design that received final design approval in 1999. Wherever possible, the AP1000 plant configuration and layout was kept the same as AP600 to take advantage of the maturity of the design and to minimize new design efforts. As a result, the two-loop configuration was maintained for AP1000, and the containment vessel diameter was kept the same. It was determined that this significant power up-rate was well within the capability of the passive safety features, and that the safety margins for AP1000 were greater than those of operating PWRs. A key feature of the passive core cooling system is the passive residual heat removal heat exchanger (PRHR HX) that provides decay heat removal for postulated LOCA and non-LOCA events. The PRHR HX is a C-tube heat exchanger located in the in-containment refueling water storage tank (IRWST) above the core promoting natural circulation heat removal between the reactor cooling system and the tank. Component testing was performed for the AP600 PRHR HX to determine the heat transfer characteristics and to develop correlations to be used for the AP1000 safety analysis codes. The data from these tests were confirmed by subsequent integral tests at three separate facilities including the ROSA facility in Japan. Owing to the importance of this component, an independent analysis has been performed using the ATHOS-based computational fluid dynamics computer code PRHRCFD. Two separate models of the PRHR HX and IRWST have been developed representing the ROSA test geometry and the AP1000 plant geometry. Confirmation of the ROSA test results were used to validate PRHRCFD, and the AP1000 plant model

  8. Efficiency of Passive Utilization of Ground “Cold” in Adaptive Geothermal Heat Pump Heating and Cooling Systems (AGHCS

    Directory of Open Access Journals (Sweden)

    Vasilyev G.P.

    2016-01-01

    Full Text Available This article deals with estimating a potential and efficiency of utilization of passive ground “cold” for cooling buildings in climatic conditions of Moscow (Russia. The article presents results of numerical analysis to assess the efficiency of reducing peak cooling loads of the building equipped with AGHCS, through the utilization of natural cold of wells for passive cooling and cold storage in summer at night (off-peak time with its subsequent consumption in the day time, both in passive mode, and with heat pumps. The conclusions of the article set out the basic principles of passive cooling in the design of AGHCS.

  9. A passive emergency heat sink for water cooled reactors with particular application to CANDU reg-sign reactors

    International Nuclear Information System (INIS)

    Spinks, N.J.

    1996-01-01

    Water in an overhead pool can serve as a general-purpose passive emergency heat sink for water-cooled reactors. It can be used for containment cooling, for emergency depressurization of the heat transport-system, or to receive any other emergency heat, such as that from the CANDU reg-sign moderator. The passive emergency water system provides in-containment depressurization of steam generators and no other provision is needed for supply of low-pressure emergency water to the steam generators. For containment cooling, the pool supplies water to the tube side of elevated tube banks inside containment. The elevation with respect to the reactor heat source maximizes heat transport, by natural convection, of hot containment gases. This effective heat transport combines with the large heat-transfer coefficients of tube banks, to reduce containment overpressure during accidents. Cooled air from the tube banks is directed past the break in the heat-transport system, to facilitate removal of hydrogen using passive catalytic recombiners

  10. Passivation of organic light emitting diode anode grid lines by pulsed Joule heating

    NARCIS (Netherlands)

    Janka, M.; Gierth, R.; Rubingh, J.E.; Abendroth, M.; Eggert, M.; Moet, D.J.D.; Lupo, D.

    2015-01-01

    We report the self-aligned passivation of a current distribution grid for an organic light emitting diode (OLED) anode using a pulsed Joule heating method to align the passivation layer accurately on the metal grid. This method involves passing an electric current through the grid to cure a polymer

  11. Heat Conductivity Resistance of Concrete Wall Panel by Water Flowing in Different Orientations of Internal PVC pipe

    Science.gov (United States)

    Umi, N. N.; Norazman, M. N.; Daud, N. M.; Yusof, M. A.; Yahya, M. A.; Othman, M.

    2018-04-01

    Green building technology and sustainability development is current focus in the world nowadays. In Malaysia and most tropical countries the maximum temperature recorded typically at 35°C. Air-conditioning system has become a necessity in occupied buildings, thereby increasing the cost of electric consumption. The aim of this study is to find out the solution in minimizing heat transfer from the external environment and intentions towards going green. In this study, the experimental work includes testing three types of concrete wall panels. The main heat intervention material in this research is 2 inch diameter Polyvinyl Chloride (PVC) pipe embedded at the center of the concrete wall panel, while the EPS foam beads were added to the cement content in the concrete mix forming the outer layer of the wall panel. Water from the rainwater harvesting system is regulated in the PVC pipe to intervene with the heat conductivity through the wall panel. Results from the experimental works show that the internal surface temperature of these heat resistance wall panels is to 3□C lower than control wall panel from plain interlocking bricks.

  12. Sustainable Heating, Cooling and Ventilation of a Plus-Energy House via Photovoltaic/Thermal Panels

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Skrupskelis, Martynas; Sevela, Pavel

    2014-01-01

    Present work addresses the HVAC and energy concerns of the Technical University of Denmark's house, Fold, for the competition Solar Decathlon Europe 2012. Various innovative solutions are investigated; photovoltaic/thermal (PV/T) panels, utilization of ground as a heat source/sink and phase change...... two separate systems. PV/T panels enable the house to perform as a plus-energy house. PV/T also yields to a solar fraction of 63% and 31% for Madrid and Copenhagen, respectively. The ground heat exchanger acts as the heat sink/source of the house. Free cooling enables the same cooling effect...

  13. Computational and experimental studies of microvascular void features for passive-adaptation of structural panel dynamic properties

    Science.gov (United States)

    Sears, Nicholas C.; Harne, Ryan L.

    2018-01-01

    The performance, integrity, and safety of built-up structural systems are critical to their effective employment in diverse engineering applications. In conflict with these goals, harmonic or random excitations of structural panels may promote large amplitude oscillations that are particularly harmful when excitation energies are concentrated around natural frequencies. This contributes to fatigue concerns, performance degradation, and failure. While studies have considered active or passive damping treatments that adapt material characteristics and configurations for structural control, it remains to be understood how vibration properties of structural panels may be tailored via internal material transitions. Motivated to fill this knowledge gap, this research explores an idea of adapting the static and dynamic material distribution of panels through embedded microvascular channels and strategically placed voids that permit the internal movement of fluids within the panels for structural dynamic control. Finite element model and experimental investigations probe how redistributing material in the form of microscale voids influences the global vibration modes and natural frequencies of structural panels. Through parameter studies, the relationships among void shape, number, size, and location are quantified towards their contribution to the changing structural dynamics. For the panel composition and boundary conditions considered in this report, the findings reveal that transferring material between strategically placed voids may result in eigenfrequency changes as great as 10.0, 5.0, and 7.4% for the first, second, and third modes, respectively.

  14. Forearm cutaneous vascular and sudomotor responses to whole body passive heat stress in young smokers.

    Science.gov (United States)

    Moyen, Nicole E; Anderson, Hannah M; Burchfield, Jenna M; Tucker, Matthew A; Gonzalez, Melina A; Robinson, Forrest B; Ganio, Matthew S

    2015-07-01

    The purpose of this study was to compare smokers and nonsmokers' sudomotor and cutaneous vascular responses to whole body passive heat stress. Nine regularly smoking (SMK: 29 ± 9 yr; 10 ± 6 cigarettes/day) and 13 nonsmoking (N-SMK: 27 ± 8 yr) males were passively heated until core temperature (TC) increased 1.5°C from baseline. Forearm local sweat rate (LSR) via ventilated capsule, sweat gland activation (SGA), sweat gland output (SGO), and cutaneous vasomotor activity via laser-Doppler flowmetry (CVC) were measured as mean body temperature increased (ΔTb) during passive heating using a water-perfused suit. Compared with N-SMK, SMK had a smaller ΔTb at the onset of sweating (0.52 ± 0.19 vs. 0.35 ± 0.14°C, respectively; P = 0.03) and cutaneous vasodilation (0.61 ± 0.21 vs. 0.31 ± 0.12°C, respectively; P body heating was higher in N-SMK vs. SMK (1.00 ± 0.13 vs. 0.79 ± 0.26 mg·cm(-2)·min(-1); P = 0.03), which was likely a result of higher SGO (8.94 ± 3.99 vs. 5.94 ± 3.49 μg·gland(-1)·min(-1), respectively; P = 0.08) and not number of SGA (104 ± 7 vs. 121 ± 9 glands/cm(2), respectively; P = 0.58). During whole body passive heat stress, smokers had an earlier onset for forearm sweating and cutaneous vasodilation, but a lower local sweat rate that was likely due to lower sweat output per gland. These data provide insight into local (i.e., forearm) thermoregulatory responses of young smokers during uncompensatory whole body passive heat stress. Copyright © 2015 the American Physiological Society.

  15. Summary report of RAMONA investigations into passive decay heat removal

    International Nuclear Information System (INIS)

    Hoffmann, H.; Marten, K.; Weinberg, D.; Frey, H.H.; Rust, K.; Ieda, Y.; Kamide, H.; Ohshima, H.; Ohira, H.

    1995-07-01

    An important safety feature of an advanced sodium-cooled reactor (e.g. European Fast Reactor, EFR) is the passive decay heat removal. This passive concept is based on several direct reactor cooling systems operating independently from each other. Each of the systems consists of a sodium/sodium decay heat exchanger immersed in the primary vessel and connected via an intermediate sodium loop to a heat sink formed by a sodium/air heat exchanger installed in a stack with air inlet and outlet dampers. The decay heat is removed by natural convection on the sodium side and natural draft on the air side. To demonstrate the coolability of the pool-type primary system by buoyancy-driven natural circulation, tests were performed under steady-state and transient conditions in facilities of different scale and detail. All these investigations serve to understand the physical processes and to verify computer codes used to transfer the results to reactor conditions. RAMONA is the three-dimensional 1:20-scaled apparatus equipped with all active components. Water is used as simulant fluid for sodium. The maximum core power is 75 kW. The facility is equipped with about 250 thermocouples to register fluid temperatures. Velocities and mass flows are measured by Laser Doppler Anemometers and magneto-inductive flowmeters. Flow paths are visualized by tracers. The conclusion of the investigations is that the decay heat can be removed from the primary system by means of natural convection. Always flow paths develop, which ensure an effective cooling of all regions. This is even proved for extreme conditions, e.g. in case of delays of the decay heat exchanger startup, failures of several DHR chains, and a drop of the fluid level below the inlet windows of the IHXs and decay heat exchangers. (orig.) [de

  16. Application study of the heat pipe to the passive decay heat removal system of the modular HTR

    International Nuclear Information System (INIS)

    Ohashi, K.; Okamoto, F.; Hayakawa, H.; Hayashi, T.

    2001-01-01

    To investigate the applicability of the heat pipe to the decay hat removal (DHR) system of the modular HTRs, preliminary study of the Heat Pipe DHR System was performed. The results show that the Heat Pipe DHR System is applicable to the modular HTRs and its heat removal capability is sufficient. Especially by applying the variable conductance heat pipe, the possibility of a fully passive DHR system with lower heat loss during normal operation is suggested. The experiments to obtain the fundamental characteristics data of the variable conductance heat pipe were carried out. The experimental results show very clear features of self-control characteristics. The experimental results and the experimental analysis results are also shown. (author)

  17. Design of passive decay heat removal system using thermosyphon for low temperature and low pressure pool type LWR

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jangsik; You, Byung Hyun; Jung, Yong Hun; Jeong, Yong Hoon [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2013-10-15

    In seawater desalination process which doesn't need high temperature steam, the reactor has profitability. KAIST has be developing the new reactor design, AHR400, for only desalination. For maximizing safety, the reactor requires passive decay heat removal system. In many nuclear reactors, DHR system is loop form. The DHR system can be designed simple by applying conventional thermosyphon, which is fully passive device, shows high heat transfer performance and simple structure. DHR system utilizes conventional thermosyphon and its heat transfer characteristics are analyzed for AHR400. For maximizing safety of the reactor, passive decay heat removal system are prepared. Thermosyphon is useful device for DHR system of low pressure and low temperature pool type reactor. Thermosyphon is operated fully passive and has simple structure. Bundle of thermosyphon get the goal to prohibit boiling in reactor and high pressure in reactor vessel.

  18. A concept of passive safety pressurized water reactor system with inherent matching nature of core heat generation and heat removal

    International Nuclear Information System (INIS)

    Murao, Yoshio; Araya, Fumimasa; Iwamura, Takamichi; Okumura, Keisuke

    1995-01-01

    The reduction of manpower in operation and maintenance by simplification of the system are essential to improve the safety and the economy of future light water reactors. At the Japan Atomic Energy Research Institute (JAERI), a concept of a simplified passive safety reactor system JPSR was developed for this purpose and in the concept minimization of developing work and conservation of scale-up capability in design were considered. The inherent matching nature of core heat generation and heat removal rate is introduced by the core with high reactivity coefficient for moderator density and low reactivity coefficient for fuel temperature (Doppler effect) and once-through steam generators (SGs). This nature makes the nuclear steam supply system physically-slave for the steam and energy conversion system by controlling feed water mass flow rate. The nature can be obtained by eliminating chemical shim and adopting in-vessel control rod drive mechanism (CRDM) units and a low power density core. In order to simplify the system, a large pressurizer, canned pumps, passive residual heat removal systems with air coolers as a final heat sink and passive coolant injection system are adopted and the functions of volume and boron concentration control and seal water supply are eliminated from the chemical and volume control system (CVCS). The emergency diesel generators and auxiliary component cooling system of 'safety class' for transferring heat to sea water as a final heat sink in emergency are also eliminated. All of systems are built in the containment except for the air coolers of the passive residual heat removal system. The analysis of the system revealed that the primary coolant expansion in 100% load reduction in 60 s can be mitigated in the pressurizer without actuating the pressure relief valves and the pressure in 50% load change in 30 s does not exceed the maximum allowable pressure in accidental conditions in regardless of pressure regulation. (author)

  19. Ocular blood flow decreases during passive heat stress in resting humans

    OpenAIRE

    Ikemura, Tsukasa; Miyaji, Akane; Kashima, Hideaki; Yamaguchi, Yuji; Hayashi, Naoyuki

    2013-01-01

    Background Heat stress induces various physiological changes and so could influence ocular circulation. This study examined the effect of heat stress on ocular blood flow. Findings Ocular blood flow, end-tidal carbon dioxide (P ETCO2) and blood pressure were measured for 12 healthy subjects wearing water-perfused tube-lined suits under two conditions of water circulation: (1) at 35°C (normothermia) for 30 min and (2) at 50°C for 90 min (passive heat stress). The blood-flow velocities in the s...

  20. Field evaluation of performance of radiant heating/cooling ceiling panel system

    DEFF Research Database (Denmark)

    Li, Rongling; Yoshidomi, Togo; Ooka, Ryozo

    2015-01-01

    heating/coolingceiling panel system is used. However, no standard exists for the in situ performance evaluation of radiantheating/cooling ceiling systems; furthermore, no published database is available for comparison. Thus,this study aims to not only clarify the system performance but also to share our...... experience and our resultsfor them to serve as a reference for other similar projects. Here, the system performance in relation toits heating/cooling capacity and thermal comfort has been evaluated. The heat transfer coefficient fromwater to room was 3.7 W/(m2K) and 4.8 W/(m2K) for heating and cooling cases...

  1. Hybrid heat pipe based passive cooling device for spent nuclear fuel dry storage cask

    International Nuclear Information System (INIS)

    Jeong, Yeong Shin; Bang, In Cheol

    2016-01-01

    Highlights: • Hybrid heat pipe was presented as a passive cooling device for dry storage cask of SNF. • A method to utilize waste heat from spent fuel was suggested using hybrid heat pipe. • CFD analysis was performed to evaluate the thermal performance of hybrid heat pipe. • Hybrid heat pipe can increase safety margin and storage capacity of the dry storage cask. - Abstract: Conventional dry storage facilities for spent nuclear fuel (SNF) were designed to remove decay heat through the natural convection of air, but this method has limited cooling capacity and a possible re-criticality accident in case of flooding. To enhance the safety and capacity of dry storage cask of SNF, hybrid heat pipe-based passive cooling device was suggested. Heat pipe is an excellent passive heat transfer device using the principles of both conduction and phase change of the working fluid. The heat pipe containing neutron absorber material, the so-called hybrid heat pipe, is expected to prevent the re-criticality accidents of SNF and to increase the safety margin during interim and long term storage period. Moreover, a hybrid heat pipe with thermoelectric module, a Stirling engine and a phase change material tank can be used for utilization of the waste heat as heat-transfer medium. Located at the guide tube or instrumentation tube, hybrid heat pipe can remove decay heat from inside the sealed metal cask to outside, decreasing fuel rod temperature. In this paper, a 2-step analysis was performed using computational fluid dynamics code to evaluate the heat and fluid flow inside a cask, which consisted of a single spent fuel assembly simulation and a full-scope dry cask simulation. For a normal dry storage cask, the maximum fuel temperature is 290.0 °C. With hybrid heat pipe cooling, the temperature decreased to 261.6 °C with application of one hybrid heat pipe per assembly, and to 195.1 °C with the application of five hybrid heat pipes per assembly. Therefore, a dry

  2. Effect of a patent foramen ovale in humans on thermal responses to passive cooling and heating.

    Science.gov (United States)

    Davis, James T; Hay, Madeline W; Hardin, Alyssa M; White, Matthew D; Lovering, Andrew T

    2017-12-01

    Humans with a patent foramen ovale (PFO) have a higher esophageal temperature (T esoph ) than humans without a PFO (PFO-). Thus the presence of a PFO might also be associated with differences in thermal responsiveness to passive cooling and heating such as shivering and hyperpnea, respectively. The purpose of this study was to determine whether thermal responses to passive cooling and heating are different between PFO- subjects and subjects with a PFO (PFO+). We hypothesized that compared with PFO- subjects PFO+ subjects would cool down more rapidly and heat up slower and that PFO+ subjects who experienced thermal hyperpnea would have a blunted increase in ventilation. Twenty-seven men (13 PFO+) completed two trials separated by >48 h: 1 ) 60 min of cold water immersion (19.5 ± 0.9°C) and 2 ) 30 min of hot water immersion (40.5 ± 0.2°C). PFO+ subjects had a higher T esoph before and during cold water and hot water immersion ( P heating. NEW & NOTEWORTHY Patent foramen ovale (PFO) is found in ~25-40% of the population. The presence of a PFO appears to be associated with a greater core body temperature and blunted ventilatory responses during passive heating. The reason for this blunted ventilatory response to passive heating is unknown but may suggest differences in thermal sensitivity in PFO+ subjects compared with PFO- subjects. Copyright © 2017 the American Physiological Society.

  3. Concepts for passive heat removal and filtration systems under core meltdown conditions

    International Nuclear Information System (INIS)

    Wilhelm, J.G.; Neitzel, H.-J.

    1993-01-01

    The objective of the new containment concept being developed by KfK is the complete passive enclosure of a power reactor after a core meltdown accident by means of a solid containment structure and passive removal of the decay heat. This is to be accomplished by cooling the containment walls with ambient air, with thermoconvection as the driving force. The concept of the containment is described. Data are given of the heat removal and the requirements for filtration of the exhaust air, which is contaminated due to the leak rate assumed for the inner containment. The concept for the filter system is described. Various solutions for reduction of the large volumetric flow to be filtered are discussed. 3 refs., 8 figs

  4. Experimental investigation on passive heat transfer by long closed two-phase thermosiphons

    Energy Technology Data Exchange (ETDEWEB)

    Grass, Claudia; Kulenovic, Rudi; Starflinger, Joerg [Stuttgart Univ. (Germany). Inst. fuer Kernenergetik und Energiesysteme (IKE)

    2017-07-15

    The removal of decay heat from spent fuel pools is presently realized by active cooling systems. In case of a station black out, a passive heat removal based on closed two-phase thermosiphons can contribute to the power plant safety. In this paper, the basic laboratory setup for closed two-phase thermosiphons and first experimental results are presented. Depending on the driving temperature difference and the heat input, steady-state and pulsating operation of the thermosiphons are investigated.

  5. Integrated application of combined cooling, heating and power poly-generation PV radiant panel system of zero energy buildings

    Science.gov (United States)

    Yin, Baoquan

    2018-02-01

    A new type of combined cooling, heating and power of photovoltaic radiant panel (PV/R) module was proposed, and applied in the zero energy buildings in this paper. The energy system of this building is composed of PV/R module, low temperature difference terminal, energy storage, multi-source heat pump, energy balance control system. Radiant panel is attached on the backside of the PV module for cooling the PV, which is called PV/R module. During the daytime, the PV module was cooled down with the radiant panel, as the temperature coefficient influence, the power efficiency was increased by 8% to 14%, the radiant panel solar heat collecting efficiency was about 45%. Through the nocturnal radiant cooling, the PV/R cooling capacity could be 50 W/m2. For the multifunction energy device, the system shows the versatility during the heating, cooling and power used of building utilization all year round.

  6. Simulation of a passive house coupled with a heat pump/organic Rankine cycle reversible unit

    DEFF Research Database (Denmark)

    Dumont, Olivier; Carmo, Carolina; Randaxhe, François

    2014-01-01

    This paper presents a dynamic model of a passive house located in Denmark with a large solar absorber, a horizontal ground heat exchanger coupled with a HP/ORC unit. The HP/ORC reversible unit is a module able to work as an Organic Rankine Cycle (ORC) or as a heat pump (HP). There are 3 possible ...... presents a higher global COP because the heat produced on the roof can heat the storage directly.......This paper presents a dynamic model of a passive house located in Denmark with a large solar absorber, a horizontal ground heat exchanger coupled with a HP/ORC unit. The HP/ORC reversible unit is a module able to work as an Organic Rankine Cycle (ORC) or as a heat pump (HP). There are 3 possible...... modes that need to be chosen optimally depending on the weather conditions, the heat demand and the temperature level of the storage. The ORC mode is activated, as long as the heat demand of the house is covered by the storage to produce electricity based upon the heat generated by the solar roof...

  7. Heating Performance Study on a Passive Solar Heater

    Directory of Open Access Journals (Sweden)

    Naz Muhammad Y.

    2017-01-01

    Full Text Available A passive thermosyphon heating system was designed, fabricated and tested for its thermal performance in semi-arid and four-season climate of Pakistan. The heating system design was based on a two-stage storage and natural thermosyphon circulation of the water. The objective of the study was to enhance the heating performance of the thermosyphon systems by using a semicircular steel pot collector, water carrying copper coil cover, two step water storage, and side mirror reflectors. The experiments were conducted during April to July 2014 when ambient temperature was reported to vary between 32°C and 44°C. In continuous flow mode operation, the hot water temperature remained between 46°C and 78°C. Since water temperature in the range of 45°C to 50°C is considered suitable for the domestic use, the presented design can easily reach the temperatures even higher than those acceptable for the domestic use.

  8. Introduction of a method of constructing heat preventing panels in holds in freezing carrier. Reito unpansen ni okeru sonai bonetsu panel koho no shokai

    Energy Technology Data Exchange (ETDEWEB)

    Kawaki, T; Fujita, H; Yamamoto, K

    1994-06-25

    A freezing carrier is a dedication ship to transport frozen and refrigerated cargoes such as foodstuffs loaded in holds. Ship's heat preventing devices must have the heat insulating structure formed according to complex shapes characteristic to an ocean vessel, and the most part of the work is done by skilled technicians working on the site. Therefore, discussions have been given on a heat preventing structure using a panel construction method aiming at simplifying cross sections to more efficient and uniform shapes, and hold shapes and work in them to more suitable for palletized packaging styles, and improving working environments. The results of the discussions have been applied to two ships for the first time, and the effects have been verified. This paper reports its specifications and construction. The heat preventing panel is a sandwiched composite of a surface material and a polyurethane foam, made to a panel size of about 1 m [times] 2 m. Joints are fixed by fasteners. The present ships have adopted such a form that the side walls are vertical, but the floor area and the clear height are the same as the conventional construction methods. Good heat insulation performance and workability have been verified, and results that are expected of further development have been obtained. 7 figs.

  9. Multiobjective optimization for design of multifunctional sandwich panel heat pipes with micro-architected truss cores

    International Nuclear Information System (INIS)

    Roper, Christopher S.

    2011-01-01

    A micro-architected multifunctional structure, a sandwich panel heat pipe with a micro-scale truss core and arterial wick, is modeled and optimized. To characterize multiple functionalities, objective equations are formulated for density, compressive modulus, compressive strength, and maximum heat flux. Multiobjective optimization is used to determine the Pareto-optimal design surfaces, which consist of hundreds of individually optimized designs. The Pareto-optimal surfaces for different working fluids (water, ethanol, and perfluoro(methylcyclohexane)) as well as different micro-scale truss core materials (metal, ceramic, and polymer) are determined and compared. Examination of the Pareto fronts allows comparison of the trade-offs between density, compressive stiffness, compressive strength, and maximum heat flux in the design of multifunctional sandwich panel heat pipes with micro-scale truss cores. Heat fluxes up to 3.0 MW/m 2 are predicted for silicon carbide truss core heat pipes with water as the working fluid.

  10. Cooling characteristics of light and heat composite panel; Hikari{center_dot}netsu fukugo paneru no rekyakutokusei

    Energy Technology Data Exchange (ETDEWEB)

    Machida, Satoshi [Science University of Tokyo, Tokyo (Japan)

    1999-07-31

    The Japan Solar Energy Soc. encouraging prize is really thank you this time receiving. Present winning prize is regarded as becoming large self-confidence and further encouragement in advancing the research in future. Duplicates and resources energy depletion problem and environmental problem, etc. will become serious more and more in respect of the twenty-first century just before. It is the threat even in the inside on the increase of the electric power demand by the popularization of air conditioner, etc., and peak shaving of the electric power, etc. must be urgently carried out. We heavily carry out the research of catching, width shot heating and cooling panel constituted by the thermo device module and light and heat composite panel which combined photovoltaic power generation panel in respect of this problem. The development of this panel was solved with the purpose this time, we produce the test equipment experimentally in outdoors, and the data was acquired. As the result, though it is possible to obtain the case in which it operated as air-cooling this panel, and temperature gradient of largest 6 degrees C, and it is the analysis, and it 4s, when it was used in July, It was possible to obtain 4.2 degrees C mean temperature difference. It is the place which has installed improved light and heat composite panel in which we suggested afterwards trial and error at present in the roof. And, it will become also reporting schedule on heating characteristics of this panel in future. Though it consists finally, everybody of Komatsu central laboratory, who received support, when this study was carried out, is asked for the slender face, the attention of thanks is shown. (translated by NEDO)

  11. Numerical Model and Experimental Analysis of the Thermal Behavior of Electric Radiant Heating Panels

    Directory of Open Access Journals (Sweden)

    Giovanni Ferrarini

    2018-01-01

    Full Text Available Electric radiant heating panels are frequently selected during the design phase of residential and industrial heating systems, especially for retrofit of existing buildings, as an alternative to other common heating systems, such as radiators or air conditioners. The possibility of saving living and working space and the ease of installation are the main advantages of electric radiant solutions. This paper investigates the thermal performance of a typical electric radiant panel. A climatic room was equipped with temperature sensors and heat flow meters to perform a steady state experimental analysis. For the dynamic behavior, a mathematical model was created and compared to a thermographic measurement procedure. The results showed for the steady state an efficiency of energy transformation close to one, while in a transient thermal regime the time constant to reach the steady state condition was slightly faster than the typical ones of hydronic systems.

  12. PANDA passive decay heat removal transient test results

    International Nuclear Information System (INIS)

    Bandurski, Th.; Dreier, J.; Huggenberger, M.

    1997-01-01

    PANDA is a large scale facility for investigating the long-term decay heat removal from the containment of a next generation of 'passive' Advanced Light Water Reactors (ALWR). PANDA was used to examine the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric (GE) Simplified Boiling Water Reactor (SBWR). The first PANDA test series had the dual objectives of demonstrating the performance of the SBWR PCCS and extending the data base available for containment analysis code qualification. The test objectives also include the study of the effects of mixing and stratification of steam and noncondensible gases in the drywell (DW) and in the suppression chamber or wetwell (WW). Ten tests were conducted in the course of the PANDA SBWR Program. The tests demonstrated a favorable and robust overall PCCS performance under different conditions. The present paper focuses on the main phenomena observed during the tests with respect to PCCS operation and DW gas mixing. (author)

  13. Decontamination of drinking water by direct heating in solar panels.

    Science.gov (United States)

    Fjendbo Jørgensen, A J; Nøhr, K; Sørensen, H; Boisen, F

    1998-09-01

    A device was developed for direct heating of water by solar radiation in a flow-through system of copper pipes. An adjustable thermostat valve prevents water below the chosen temperature from being withdrawn. The results show that it is possible to eliminate coliform and thermotolerant coliform bacteria from naturally contaminated river water by heating to temperatures of 65 degrees C or above. Artificial additions of Salmonella typhimurium, Streptococcus faecalis and Escherichia coli to contaminated river water were also inactivated after heating to 65 degrees C and above. The total viable count could be reduced by a factor of 1000. The heat-resistant bacteria isolated from the Mlalakuva River (Tanzania) were spore-forming bacteria which exhibited greater heat resistance than commonly used test bacteria originating from countries with colder climates. To provide a good safety margin it is recommended that an outlet water temperature of 75 degrees C be used. At that temperature the daily production was about 501 of decontaminated water per m2 of solar panel, an amount that could be doubled by using a heat exchanger to recycle the heat.

  14. A passive decay heat removal system for LWRs based on air cooling

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, Hiroyasu, E-mail: mochizki@u-fukui.ac.jp [Research Institute of Nuclear Engineering, University of Fukui, 1-2-4 Kanawa-cho, Tsuruga, Fukui 914-0055 (Japan); Yano, Takahiro [Graduate School of Engineering, University of Fukui, 1-2-4 Kanawa-cho, Tsuruga, Fukui 914-0055 (Japan)

    2015-05-15

    Highlights: • A passive decay heat removal system for LWRs is discussed. • An air cooler model which condenses steam is developed. • The decay heat can be removed by air coolers with forced convection. • The dimensions of the air cooler are proposed. - Abstract: The present paper describes the capability of an air cooling system (ACS) to remove decay heat from a core of LWR such as an advanced boiling water reactor (ABWR) and a pressurized water reactor (PWR). The motivation of the present research is the Fukushima severe accident (SA) on 11 March 2011. Since emergency cooling systems using electricity were not available due to station blackout (SBO) and malfunctions, many engineers might understand that water cooling was not completely reliable. Therefore, a passive decay heat removal (DHR) system would be proposed in order to prevent such an SA under the conditions of an SBO event. The plant behaviors during the SBO are calculated using the system code NETFLOW++ for the ABWR and PWR with the ACS. Two types of air coolers (ACs) are applied for the ABWR, i.e., a steam condensing air cooler (SCAC) of which intake for heat transfer tubes is provided in the steam region, and single-phase type of which intake is provided in the water region. The DHR characteristics are calculated under the conditions of the forced air circulation and also the natural air convection. As a result of the calculations, the decay heat can be removed safely by the reasonably sized ACS when heat transfer tubes are cooled with the forced air circulation. The heat removal rate per one finned heat transfer tube is evaluated as a function of air flow rate. The heat removal rate increases as a function of the air flow rate.

  15. A passive decay heat removal strategy of the integrated passive safety system (IPSS) for SBO combined with LOCA

    International Nuclear Information System (INIS)

    Kim, Sang Ho; Chang, Soon Heung; Choi, Yu Jung; Jeong, Yong Hoon

    2015-01-01

    Highlights: • A new PDHR strategy is proposed to cope with SBO-combined accidents. • The concept of integrated passive safety system (IPSS) is used in this strategy. • This strategy performs the functions of passive safety injection and SG gravity injection. • LOCAs in SBO are classified by the pressures in reactor coolant system for passive functions. • The strategy can be integrated with EOP and SAMG as a complementary strategy for ensuring safety. - Abstract: An integrated passive safety system (IPSS), to be achieved by the use of a large water tank placed at high elevation outside the containment, was proposed to achieve various passive functions. These include decay heat removal, safety injection, containment cooling, in-vessel retention through external reactor vessel cooling, and containment filtered venting. The purpose of the passive decay heat removal (PDHR) strategy using the IPSS is to cope with SBO and SBO-combined accidents under the assumption that existing engineered safety features have failed. In this paper, a PDHR strategy was developed based on the design and accident management strategy of Korean representative PWR, the OPR1000. The functions of a steam generator gravity injection and a passive safety injection system in the IPSS with safety depressurization systems were included in the PDHR strategy. Because the inadvertent opening of pressurizer valves and seal water leakage from RCPs could cause a loss of coolant in an SBO, LOCAs during a SBO were simulated to verify the performance of the strategy. The failure of active safety injection in LOCAs could also be covered by this strategy. Although LOCAs have generally been categorized according to their equivalent break diameters, the RCS pressure is used to classify the LOCAs during SBOs. The criteria values for categorization were determined from the proposed systems, which could maintain a reactor in a safe state by removing the decay heat for the SBO coping time of 8 h. The

  16. A passive decay heat removal strategy of the integrated passive safety system (IPSS) for SBO combined with LOCA

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Ho [Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, 291, Daehak-ro, Yuseong-gu, Daejeon 34141 (Korea, Republic of); Chang, Soon Heung [Handong Global University, 558, Handong-ro, Buk-gu, Pohang Gyeongbuk 37554 (Korea, Republic of); Choi, Yu Jung [Korea Hydro and Nuclear Power Co.—Central Research Institute, 70, 1312-gil, Yuseong-daero, Yuseong-gu, Daejeon 34101 (Korea, Republic of); Jeong, Yong Hoon, E-mail: jeongyh@kaist.ac.kr [Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, 291, Daehak-ro, Yuseong-gu, Daejeon 34141 (Korea, Republic of)

    2015-12-15

    Highlights: • A new PDHR strategy is proposed to cope with SBO-combined accidents. • The concept of integrated passive safety system (IPSS) is used in this strategy. • This strategy performs the functions of passive safety injection and SG gravity injection. • LOCAs in SBO are classified by the pressures in reactor coolant system for passive functions. • The strategy can be integrated with EOP and SAMG as a complementary strategy for ensuring safety. - Abstract: An integrated passive safety system (IPSS), to be achieved by the use of a large water tank placed at high elevation outside the containment, was proposed to achieve various passive functions. These include decay heat removal, safety injection, containment cooling, in-vessel retention through external reactor vessel cooling, and containment filtered venting. The purpose of the passive decay heat removal (PDHR) strategy using the IPSS is to cope with SBO and SBO-combined accidents under the assumption that existing engineered safety features have failed. In this paper, a PDHR strategy was developed based on the design and accident management strategy of Korean representative PWR, the OPR1000. The functions of a steam generator gravity injection and a passive safety injection system in the IPSS with safety depressurization systems were included in the PDHR strategy. Because the inadvertent opening of pressurizer valves and seal water leakage from RCPs could cause a loss of coolant in an SBO, LOCAs during a SBO were simulated to verify the performance of the strategy. The failure of active safety injection in LOCAs could also be covered by this strategy. Although LOCAs have generally been categorized according to their equivalent break diameters, the RCS pressure is used to classify the LOCAs during SBOs. The criteria values for categorization were determined from the proposed systems, which could maintain a reactor in a safe state by removing the decay heat for the SBO coping time of 8 h. The

  17. Performance of ALMR passive decay heat removal system

    International Nuclear Information System (INIS)

    Boardman, C.E.; Hunsbedt, A.

    1991-01-01

    The Advanced Liquid Metal Reactor (ALMR) concept has a totally passive safety-grade decay heat removal system referred to as the Reactor Vessel Auxiliary Cooling System (RVACS) that rejects heat from the small (471 MWt) modular reactor to the environmental air by natural convection heat transfer. The system has no active components, requires no operator action to initiate, and is inherently reliable. The RVACS can perform its function under off-normal or degraded operating conditions without significant loss in performance. Several such events are described and the RVACS thermal performance for each is given and compared to the normal operation performance. The basic RVACS performance as well as the performance during several off-normal events have been updated to reflect design changes for recycled fuel with minor actinides for end of equilibrium cycle conditions. The performance results for several other off-normal events involving various degrees of RVACS air flow passage blockages are presented. The results demonstrated that the RVACS is unusually tolerant to a wide range of postulated faults. (author)

  18. Passive Decay Heat Removal Strategy of Integrated Passive Safety System (IPSS) for SBO-combined Accidents

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Ho; Chang, Soon Heung; Jeong, Yong Hoon [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-10-15

    The weak points of nuclear safety would be in outmoded nuclear power plants like the Fukushima reactors. One of the systems for the safety enhancement is integrated passive safety system (IPSS) proposed after the Fukushima accidents. It has the five functions for the prevention and mitigation of a severe accident. Passive decay heat removal (PDHR) strategy using IPSS is proposed for coping with SBO-combined accidents in this paper. The two systems for removing decay heat before core-melt were applied in the strategy. The accidents were simulated by MARS code. The reference reactor was OPR1000, specifically Ulchin-3 and 4. The accidents included loss-of-coolant accidents (LOCA) because the coolant losses could be occurred in the SBO condition. The examples were the stuck open of PSV, the abnormal open of SDV and the leakage of RCP seal water. Also, as LOCAs with the failure of active safety injection systems were considered, various LOCAs were simulated in SBO. Based on the thermal hydraulic analysis, the probabilistic safety analysis was carried out for the PDHR strategy to estimate the safety enhancement in terms of the variation of core damage frequency. AIMS-PSA developed by KAERI was used for calculating CDF of the plant. The IPSS was applied in the PDHR strategy which was developed in order to cope with the SBO-combined accidents. The estimation for initiating SGGI or PSIS was based on the pressure in RCS. The simulations for accidents showed that the decay heat could be removed for the safety duration time in SBO. The increase of safety duration time from the strategy provides the increase of time for the restoration of AC power.

  19. Experimental research on passive residual heat remove system for advanced PWR

    International Nuclear Information System (INIS)

    Huang Yanping; Zhuo Wenbin; Yang Zumao; Xiao Zejun; Chen Bingde

    2003-01-01

    The experimental and qualified results of MISAP in the research of passive residual heat remove system of advanced PWR performed in the Bubble physics and natural circulation laboratory in Nuclear Power Institute of China in the past ten years is overviewed. Further researches for engineering research and design are also suggested

  20. Studies on Single-phase and Multi-phase Heat Pipe for LED Panel for Efficient Heat Dissipation

    Science.gov (United States)

    Vyshnave, K. C.; Rohit, G.; Maithreya, D. V. N. S.; Rakesh, S. G.

    2017-08-01

    The popularity of LED panel as a source of illumination has soared recently due to its high efficiency. However, the removal of heat that is produced in the chip is still a major challenge in its design since this has an adverse effect on its reliability. If high junction temperature develops, the colour of the emitted light may diminish over prolonged usage or even a colour shift may occur. In this paper, a solution has been developed to address this problem by using a combination of heat pipe and heat fin technology. A single-phase and a two-phase heat pipes have been designed theoretically and computational simulations carried out using ANSYS FLUENT. The results of the theoretical calculations and those obtained from the simulations are found to be in agreement with each other.

  1. Field Measurement and Evaluation of the Passive and Active Solar Heating Systems for Residential Building Based on the Qinghai-Tibetan Plateau Case

    Directory of Open Access Journals (Sweden)

    Zhijian Liu

    2017-10-01

    Full Text Available Passive and active solar heating systems have drawn much attention and are widely used in residence buildings in the Qinghai-Tibetan plateau due to its high radiation intensity. In fact, there is still lack of quantitative evaluation of the passive and active heating effect, especially for residential building in the Qinghai-Tibetan plateau areas. In this study, three kinds of heating strategies, including reference condition, passive solar heating condition and active solar heating condition, were tested in one demonstration residential building. The hourly air temperatures of each room under different conditions were obtained and analyzed. The results show the indoor air temperature in the living room and bedrooms (core zones was much higher than that of other rooms under both passive and active solar heating conditions. In addition, the heating effect with different strategies for core zones of the building was evaluated by the ratio of indoor and outdoor degree hour, which indicates that solar heating could effectively reduce the traditional energy consumption and improve the indoor thermal environment. The passive solar heating could undertake 49.8% degree hours for heating under an evaluation criterion of 14 °C and the active solar heating could undertake 75% degree hours for heating under evaluation criterion of 18 °C, which indicated that solar heating could effectively reduce the traditional energy consumption and improve the indoor thermal environment in this area. These findings could provide reference for the design and application of solar heating in similar climate areas.

  2. Experimental and analytical studies for the validation of HTR-VGD and primary cell passive decay heat removal. Supplement. Calculations

    International Nuclear Information System (INIS)

    Geiss, M.; Giannikos, A.; Hejzlar, P.; Kneer, A.

    1993-04-01

    The alternative concept for a modular HTR-reactor design by Siempelkamp, Krefeld, using a prestressed cast iron vessel (VGD) combined with a cast iron/concrete module for the primary cell with integrated passive decay heat removal system was fully qualified with respect to operational and accidental thermal loads. The main emphasis was to confirm and validate the passive decay heat removal capability. An experimental facility (INWA) was designed, instrumented and operated with an appropriate electrical heating system simulating steady-state operational and transient accidental thermal loads. The experiments were accompanied by extensive computations concerning the combination of conductive, radiative and convective energy transport mechanisms in the different components of the VGD/primary cell structures, as well as elastic-plastic stress analyses of the VGD. In addition, a spectrum of potential alternatives for passive energy removed options have been parametrically examined. The experimental data clearly demonstrate that the proposed Siempelkamp-design is able to passively and safely remove the decay heat for operational and accidental conditions without invalidating technological important thermal limits. This also holds in case of failures of both the natural convection system and ultimate heat sink by outside concrete water film cooling. (orig./HP) [de

  3. Building America Case Study: Columbia County Habitat for Humanity Passive Townhomes, Hudson, New York

    Energy Technology Data Exchange (ETDEWEB)

    2016-04-01

    Columbia County (New York) Habitat for Humanity built a pair of townhomes to Passive House criteria with the purpose of exploring approaches for achieving Passive House performance and to eventually develop a prototype design for future projects. The project utilized a 2x6 frame wall with a structural insulated panel curtain wall and a ventilated attic over a sealed OSB ceiling air barrier. Mechanical systems include a single head, wall mounted ductless mini-split heat pump in each unit and a heat recovery ventilator. Costs were $26,000 per unit higher for Passive House construction compared with the same home built to ENERGY STAR version 3 specifications, representing about 18 percent of total construction cost. This report discusses the cost components, energy modeling results and lessons from construction. Two alternative ventilation systems are analyzed: a central system; and, a point-source system with small through-wall units distributed throughout the house. The report includes a design and cost analysis of these two approaches.

  4. Passive decay heat removal by natural air convection after severe accidents

    Energy Technology Data Exchange (ETDEWEB)

    Erbacher, F.J.; Neitzel, H.J. [Forschungszentrum Karlsruhe Institut fur Angewandte Thermo- und Fluiddynamik, Karlsruhe (Germany); Cheng, X. [Technische Universitaet Karlsruhe Institut fur Stroemungslehre und Stroemungsmaschinen, Karlsruhe (Germany)

    1995-09-01

    The composite containment proposed by the Research Center Karlsruhe and the Technical University Karlsruhe is to cope with severe accidents. It pursues the goal to restrict the consequences of core meltdown accidents to the reactor plant. One essential of this new containment concept is its potential to remove the decay heat by natural air convection and thermal radiation in a passive way. To investigate the coolability of such a passive cooling system and the physical phenomena involved, experimental investigations are carried out at the PASCO test facility. Additionally, numerical calculations are performed by using different codes. A satisfying agreement between experimental data and numerical results is obtained.

  5. Comparison of swimming pools alternative passive and active heating systems based on renewable energy sources in Southern Europe

    International Nuclear Information System (INIS)

    Katsaprakakis, Dimitris Al.

    2015-01-01

    This article examines different passive and active heating systems for swimming pools. The passive systems introduced in this article are: * The swimming pools' enclosure. * The placement of floating insulating covers on the pools' surfaces whenever they are not used. The examined active systems in this article are: * A biomass heater. * A biomass heater and solar collectors combi-system. * Vertical geothermal heat exchangers (GHE) co-operating with geothermal heat pumps (GHP). The methodology employed for the introduced systems' evaluation is the arithmetic computational simulation of the swimming pools' annual heating, using annual time series of averaged hourly values for the available solar radiation and the calculated pools' thermal power demand (heating loads). The dimensioning of the active systems aims at the maximisation of the heating production from R.E.S. (renewable energy sources). and the optimisation of the corresponding investments' economic indexes. The examined systems are evaluated technically and economically versus fundamental criteria. It is proved that significant reduction of the heating loads is achieved with the introduced passive systems. The reduced swimming pools' heating loads can be successfully covered by the proposed R.E.S. active systems. The fossil fuels consumption is eliminated. The corresponding investments' payback periods can be lower than 5 years. - Highlights: • The passive solar systems reduce the swimming pools heating loads more than 90%. • The examined active heating system exhibit payback periods lower than 3.5 years. • The energy saving is maximised with a biomass heater – solar collectors system. • Single biomass heaters exhibits the shortest payback period. • GHE–GHP can be used in cases of low solar radiation and lack of biomass fuels

  6. Temperature and blood flow distribution in the human leg during passive heat stress.

    Science.gov (United States)

    Chiesa, Scott T; Trangmar, Steven J; González-Alonso, José

    2016-05-01

    The influence of temperature on the hemodynamic adjustments to direct passive heat stress within the leg's major arterial and venous vessels and compartments remains unclear. Fifteen healthy young males were tested during exposure to either passive whole body heat stress to levels approaching thermal tolerance [core temperature (Tc) + 2°C; study 1; n = 8] or single leg heat stress (Tc + 0°C; study 2; n = 7). Whole body heat stress increased perfusion and decreased oscillatory shear index in relation to the rise in leg temperature (Tleg) in all three major arteries supplying the leg, plateauing in the common and superficial femoral arteries before reaching severe heat stress levels. Isolated leg heat stress increased arterial blood flows and shear patterns to a level similar to that obtained during moderate core hyperthermia (Tc + 1°C). Despite modest increases in great saphenous venous (GSV) blood flow (0.2 l/min), the deep venous system accounted for the majority of returning flow (common femoral vein 0.7 l/min) during intense to severe levels of heat stress. Rapid cooling of a single leg during severe whole body heat stress resulted in an equivalent blood flow reduction in the major artery supplying the thigh deep tissues only, suggesting central temperature-sensitive mechanisms contribute to skin blood flow alone. These findings further our knowledge of leg hemodynamic responses during direct heat stress and provide evidence of potentially beneficial vascular alterations during isolated limb heat stress that are equivalent to those experienced during exposure to moderate levels of whole body hyperthermia. Copyright © 2016 the American Physiological Society.

  7. Diversified emergency core cooling in CANDU with a passive moderator heat rejection system

    Energy Technology Data Exchange (ETDEWEB)

    Spinks, N [AECL Research, Chalk River Labs., Chalk River, ON (Canada)

    1996-12-01

    A passive moderator heat rejection system is being developed for CANDU reactors which, combined with a conventional emergency-coolant injection system, provides the diversity to reduce core-melt frequency to order 10{sup -7} per unit-year. This is similar to the approach used in the design of contemporary CANDU shutdown systems which leads to a frequency of order 10{sup -8} per unit-year for events leading to loss of shutdown. Testing of a full height 1/60 power-and-volume-scaled loop has demonstrated the feasibility of the passive system for removal of moderator heat during normal operation and during accidents. With the frequency of core-melt reduced, by these measures, to order 10{sup -7} per unit year, no need should exist for further mitigation. (author). 3 refs, 2 figs.

  8. Passive deca-heat removal in the fixed bed nuclear reactor (FBNR) - 15551

    International Nuclear Information System (INIS)

    Solano Diaz, E.C.; Luna Aguilera, G.M.; Santos, R.A.; Vaca, D.E.

    2015-01-01

    The Fixed Bed Nuclear Reactor (FBNR) is a Generation IV small reactor concept, where the spherical elements contain Triso-type microspheres with UO 2 , which serves as nuclear fuel. In the event that adverse operation conditions occur, the water pump is automatically shut off and the fuel pebbles fall back by gravity into the fuel chamber. Since the FBNR relies on passive security systems, the removal of the decay heat in the fuel chamber is achieved by contact with quiescent water. In the present paper, a mathematical simulation of the passive cooling of the system was conducted in SOLIDWORKS so as to obtain a temperature profile in the body during the decay heat removal process. Homogenization techniques were employed to smooth out spatial variations across the multiphase system and to derive expression for the effective thermophysical properties that are valid through the macroscopic entry (the chamber). The simulation showed that the chamber's temperature rose from 573 K to its maximum temperature, 1234 K, in the first hour. Afterwards, the temperature fluctuated, but stayed under 552 K. Since the temperature of the system was always kept under the value of the safety parameter (1200 C. degrees) the simulation confirmed that an effective passive cooling of the fuel chamber is indeed feasible. (authors)

  9. Environmental impact of passive house nursery

    Energy Technology Data Exchange (ETDEWEB)

    Vares, S., Email: sirje.vares@vtt.fi

    2012-06-15

    It is often believed that reduction in energy use automatically leads to the total reduction of the carbon footprint and other emissions. To achieve better energy efficiency more raw materials may be needed not only for insulation and better windows but also for heating systems like ground source heat and solar panels. The use of advanced building systems increase the use of electricity and in winter where electricity production is already inadequate the additional stand-by power plants must be taken in use. These are not as effective as CHP plants for heat production. Moreover also the passive house structures can be produced in dozens ways and from many different materials which all have different service life, different need for maintenance and also different effect on the overall carbon footprint. Finally as the nursery is the overall concept, besides the building structures outdoor playgrounds and specific operations requiring day care trips, personnel commuting and waste treatment must be taken into account. (orig.)

  10. Study on the optium operation of the solar assisted air-source heat pump system. Part 5. ; Fundamental performance of a SOL-AIR PANEL effected by environmental condition that can be controlled artifically. SOL-AIR heat pump system no saiteki untenho ni kansuru kenkyu. 5. ; Jinko kankyo joken hendo ni uoru shuhonetsu panel no kiso tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Y; Ohashi, K; Kasuya, A [Kogauin Univ., Tokyo (Japan); Shiraishi, K; Hino, T [Kajima Institute of Construction Technology, Tokyo (Japan)

    1990-12-06

    This paper follows the privious paper which reports about the experimental system of the solar air panel and the experimental conditions in the artificial environmental room. In this paper the basic performance of heat exchange of a solar panel related to the difference of the artificial enviromental conditions such as the wind speed, the wind direction, the radiation, and the dry or wet surface of the solar air panel, and the results of its analysis are presented. As a result of the experiment, the following were determined: wind direction affects the heat exchange characteristics of the solar air panel; the slits lead to improved heat conduction on both sides of the panel; and when the flat surface of the panel is wet the amount of all the heat exchange increases, due to increased air circulation and evaporation. It is possible to estimate the total quantity of heat exchange, and to determine the fundamental performance of a solar air panel. 7 refs., 10 figs.

  11. Performance Analysis of Photovoltaic Panels with Earth Water Heat Exchanger Cooling

    Directory of Open Access Journals (Sweden)

    Jakhar Sanjeev

    2016-01-01

    Full Text Available The operating temperature is an important factor affecting the performance and life span of the Photovoltaic (PV panels. The rising temperature can be maintained within certain limit using proper cooling techniques. In the present research a novel system for cooling of PV panels named as Earth Water Heat Exchanger (EWHE is proposed and modelled in transient analysis simulation tool (TRNSYS v17.0 for the conditions of Pilani, Rajasthan (India.The various parameters which include cell temperature, PV power output and cell efficiency are observed with respect to variation in mass flow rate of fluid. Simulation results of the system without cooling show that the maximum PV panel temperature reached up to 79.31 °C with electrical efficiency dropped to 9% during peak sunshine hour. On the other hand, when PV panels are coupled with EWHE system, the panel temperature drops to 46.29 °C with an efficiency improving to 11% for a mass flow rate of 0.022 kg/s. In the end the cooling potential of EWHE is found to be in direct correlation with mass flow rate. The proposed system is very useful for the arid regions of western India which are blessed with high solar insolation throughout the year.

  12. Optimised air-heating for Minergie-P and passive housing; Optimierte Luftheizung fuer Minergie-P und Passivhaeuser

    Energy Technology Data Exchange (ETDEWEB)

    Haas, A.; Dorer, V.

    2004-07-01

    This extensive report for the Swiss Federal Office of Energy (SFOE) presents the results of a project concerning so-called 'passive' houses which exhibit extremely low energy consumption. The authors state that the findings also apply to the Swiss 'Minergie-P' standard. The aims of the project are quoted, including ways of simplifying the air distribution system, possibilities of using air-based heating systems for non-passive housing, how the building's mass can be used as a heat exchanger and for heat storage and what requirements are to be placed on the small wood-fired ovens often found in such houses. Topics discussed include temperatures and temperature gradients, thermal comfort, draught risks and air-flow rates. Further, questions concerning heat-distribution and control systems, fire and noise protection and humidity are discussed, as are heat losses and gains. Examples of dwellings being examined as part of pilot and demonstration projects are given.

  13. Study of passive residual heat removal system of a modular small PWR reactor

    International Nuclear Information System (INIS)

    Araujo, Nathália N.; Su, Jian

    2017-01-01

    This paper presents a study on the passive residual heat removal system (PRHRS) of a small modular nuclear reactor (SMR) of 75MW. More advanced nuclear reactors, such as generation III + and IV, have passive safety systems that automatically go into action in order to prevent accidents. The purpose of the PRHRS is to transfer the decay heat from the reactor's nuclear fuel, keeping the core cooled after the plant has shut down. It starts operating in the event of fall of power supply to the nuclear station, or in the event of an unavailability of the steam generator water supply system. Removal of decay heat from the core of the reactor is accomplished by the flow of the primary refrigerant by natural circulation through heat exchangers located in a pool filled with water located above the core. The natural circulation is caused by the density gradient between the reactor core and the pool. A thermal and comparative analysis of the PRHRS was performed consisting of the resolution of the mass conservation equations, amount of movement and energy and using incompressible fluid approximations with the Boussinesq approximation. Calculations were performed with the aid of Mathematica software. A design of the heat exchanger and the cooling water tank was done so that the core of the reactor remained cooled for 72 hours using only the PRHRS

  14. The thermal performance of a loop-type heat pipe for passively removing residual heat from spent fuel pool

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, Zhenqin [School of Nuclear Science and Engineering, Shanghai Jiao Tong University, No. 800 Dongchuan Road, Shanghai 200240 (China); Gu, Hanyang, E-mail: guhanyang@stu.edu.cn [School of Nuclear Science and Engineering, Shanghai Jiao Tong University, No. 800 Dongchuan Road, Shanghai 200240 (China); Wang, Minglu [School of Nuclear Science and Engineering, Shanghai Jiao Tong University, No. 800 Dongchuan Road, Shanghai 200240 (China); Cheng, Ye [Shanghai Nuclear Engineering Research and Design Institute, Shanghai 200233 (China)

    2014-12-15

    Highlights: • Feasibility of applying loop-type heat pipes for SFP is studied. • The heat transfer rate of the heat pipes was tested. • The heat transfer coefficient was between 200 and 490 W/m{sup 2}/s. • The effect of the water temperature is dominant. • Three kinds of the filling ratio 27%, 21% and 14% are compared. - Abstract: Heat pipe is an efficient heat transfer device without electrically driven parts. Therefore large-scale loop type heat pipe systems have potential uses for passively removing heat from spent fuel pools and reactor cores under the accidental conditions to improve the safety of the nuclear power station. However, temperature difference between the hot water in the spent fuel pool and the ambient air which is the heat sink is small, in the range of 20–60 °C. To understand and predict the heat removal capacity of such a large scale loop type heat pipe in the situation similar to the accidental condition of the spent fuel pool (SFP) for the design purpose, a loop-type heat pipe with a very high and large evaporator has been fabricated and was tested using ammonia as the working fluid. The evaporator with inner diameter of 65 mm and length of 7.6 m is immersed in a hot water tube which simulate the spent fuel pool. The condenser of the loop-type heat pipe is cooled by the air. The tests were performed with the velocity of the hot water in the tube in the range of 0.7–2.1 × 10{sup −2} m/s, the hot water inlet temperature between 50 and 90 °C and the air velocity ranging from 0.5 m/s to 2.5 m/s. Three kinds of the ammonia volumetric filling ratio in the heat pipe were tested, i.e. 27%, 21% and 14%. It is found that the heat transfer rate was in the range of 1.5–14.9 kW, and the heat transfer coefficient of evaporator was between 200 and 490 W/m{sup 2}/s. It is feasible to use the large scale loop type heat pipe to passively remove the residual heat from SFP. Furthermore, the effect of air velocity, air temperature, water flow

  15. The thermal performance of a loop-type heat pipe for passively removing residual heat from spent fuel pool

    International Nuclear Information System (INIS)

    Xiong, Zhenqin; Gu, Hanyang; Wang, Minglu; Cheng, Ye

    2014-01-01

    Highlights: • Feasibility of applying loop-type heat pipes for SFP is studied. • The heat transfer rate of the heat pipes was tested. • The heat transfer coefficient was between 200 and 490 W/m 2 /s. • The effect of the water temperature is dominant. • Three kinds of the filling ratio 27%, 21% and 14% are compared. - Abstract: Heat pipe is an efficient heat transfer device without electrically driven parts. Therefore large-scale loop type heat pipe systems have potential uses for passively removing heat from spent fuel pools and reactor cores under the accidental conditions to improve the safety of the nuclear power station. However, temperature difference between the hot water in the spent fuel pool and the ambient air which is the heat sink is small, in the range of 20–60 °C. To understand and predict the heat removal capacity of such a large scale loop type heat pipe in the situation similar to the accidental condition of the spent fuel pool (SFP) for the design purpose, a loop-type heat pipe with a very high and large evaporator has been fabricated and was tested using ammonia as the working fluid. The evaporator with inner diameter of 65 mm and length of 7.6 m is immersed in a hot water tube which simulate the spent fuel pool. The condenser of the loop-type heat pipe is cooled by the air. The tests were performed with the velocity of the hot water in the tube in the range of 0.7–2.1 × 10 −2 m/s, the hot water inlet temperature between 50 and 90 °C and the air velocity ranging from 0.5 m/s to 2.5 m/s. Three kinds of the ammonia volumetric filling ratio in the heat pipe were tested, i.e. 27%, 21% and 14%. It is found that the heat transfer rate was in the range of 1.5–14.9 kW, and the heat transfer coefficient of evaporator was between 200 and 490 W/m 2 /s. It is feasible to use the large scale loop type heat pipe to passively remove the residual heat from SFP. Furthermore, the effect of air velocity, air temperature, water flow rate and

  16. Wallboard with Latent Heat Storage for Passive Solar Applications; TOPICAL

    International Nuclear Information System (INIS)

    Kedl, R.J.

    2001-01-01

    Conventional wallboard impregnated with octadecane paraffin[melting point-23 C (73.5 F)] is being developed as a building material with latent heat storage for passive solar and other applications. Impregnation was accomplished simply by soaking the wallboard in molten wax. Concentrations of wax in the combined product as high as 35% by weight can be achieved. Scale-up of the soaking process, from small laboratory samples to full-sized 4- by 8-ft sheets, has been successfully accomplished. The required construction properties of wallboard are maintained after impregnation, that is, it can be painted and spackled. Long-term, high-temperature exposure tests and thermal cycling tests showed no tendency of the paraffin to migrate within the wallboard, and there was no deterioration of thermal energy storage capacity. In support of this concept, a computer model was developed to handle thermal transport and storage by a phase change material (PCM) dispersed in a porous media. The computer model was confirmed by comparison with known analytical solutions and also by comparison with temperatures measured in wallboard during an experimentally generated thermal transient. Agreement between the model and known solution was excellent. Agreement between the model and thermal transient was good, only after the model was modified to allow the PCM to melt over a temperature range, rather than at a specific melting point. When the melting characteristics of the PCM (melting point, melting range, and heat of fusion), as determined from a differential scanning calorimeter plot, were used in the model, agreement between the model and transient data was very good. The confirmed computer model may now be used in conjunction with a building heating and cooling code to evaluate design parameters and operational characteristics of latent heat storage wallboard for passive solar applications

  17. Effects of face/head and whole body cooling during passive heat stress on human somatosensory processing.

    Science.gov (United States)

    Nakata, Hiroki; Namba, Mari; Kakigi, Ryusuke; Shibasaki, Manabu

    2017-06-01

    We herein investigated the effects of face/head and whole body cooling during passive heat stress on human somatosensory processing recorded by somatosensory-evoked potentials (SEPs) at C4' and Fz electrodes. Fourteen healthy subjects received a median nerve stimulation at the left wrist. SEPs were recorded at normothermic baseline (Rest), when esophageal temperature had increased by ~1.2°C (heat stress: HS) during passive heating, face/head cooling during passive heating (face/head cooling: FHC), and after HS (whole body cooling: WBC). The latencies and amplitudes of P14, N20, P25, N35, P45, and N60 at C4' and P14, N18, P22, and N30 at Fz were evaluated. Latency indicated speed of the subcortical and cortical somatosensory processing, while amplitude reflected the strength of neural activity. Blood flow in the internal and common carotid arteries (ICA and CCA, respectively) and psychological comfort were recorded in each session. Increases in esophageal temperature due to HS significantly decreased the amplitude of N60, psychological comfort, and ICA blood flow in the HS session, and also shortened the latencies of SEPs (all, P body temperature. Copyright © 2017 the American Physiological Society.

  18. Numerical modelling of phase-change material used for PV panels cooling

    Science.gov (United States)

    Sellami, Assia; Elotmani, Rabie; Kandoussi, Khalid; Eljouad, Mohamed; Hajjaji, Abdelowahed; Boutaous, M'Hamed

    2017-12-01

    Passive cooling of a PV solar panel using phase-change material (PCM) may play an important role in increasing efficiency of PV cells. Because it does not need a maintenance and does not release greenhouses gases, PCM seems to be a good way to decrease the among of overheating of PV cell. The aims of this paper describes a detailed multiphysical issue in order to understand the effect of PCM (RT25) in keeping PV cell temperature close to ambient. The study is focused on modeling the heat and mass transfer in a PCM domain by modifying the buoyancy term in momentum equation. Due to a phase-change and free convection, transient incompressible flow is taken into account to explain the dynamic variations of the velocity profile and viscosity distribution. With standard condition of irradiation and heat flux on both sides of the PV panel, a melt front has been tracked by the energy equation, which gives a good argument for the temperature evolution during phase-change.

  19. Investigation of characteristics of passive heat removal system based on the assembled heat transfer tube

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Xiang Cheng; Yan, Changqi; Meng, Zhao Ming; Chen, Kailun; Song, Shao Chuang; Yang, Zong Hao; Yu, Jie [Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin (China)

    2016-12-15

    To get an insight into the operating characteristics of the passive residual heat removal system of molten salt reactors, a two-phase natural circulation test facility was constructed. The system consists of a boiling loop absorbing the heat from the drain tank, a condensing loop consuming the heat, and a steam drum. A steady-state experiment was carried out, in which the thimble temperature ranged from 450 .deg. C to 700 .deg. C and the system pressure was controlled at levels below 150 kPa. When reaching a steady state, the system was operated under saturated conditions. Some important parameters, including heat power, system resistance, and water level in the steam drum and water tank were investigated. The experimental results showed that the natural circulation system is feasible in removing the decay heat, even though some fluctuations may occur in the operation. The uneven temperature distribution in the water tank may be inevitable because convection occurs on the outside of the condensing tube besides boiling with decreasing the decay power. The instabilities in the natural circulation loop are sensitive to heat flux and system resistance rather than the water level in the steam drum and water tank. RELAP5 code shows reasonable results compared with experimental data.

  20. Investigation of Characteristics of Passive Heat Removal System Based on the Assembled Heat Transfer Tube

    Directory of Open Access Journals (Sweden)

    Xiangcheng Wu

    2016-12-01

    Full Text Available To get an insight into the operating characteristics of the passive residual heat removal system of molten salt reactors, a two-phase natural circulation test facility was constructed. The system consists of a boiling loop absorbing the heat from the drain tank, a condensing loop consuming the heat, and a steam drum. A steady-state experiment was carried out, in which the thimble temperature ranged from 450°C to 700°C and the system pressure was controlled at levels below 150 kPa. When reaching a steady state, the system was operated under saturated conditions. Some important parameters, including heat power, system resistance, and water level in the steam drum and water tank were investigated. The experimental results showed that the natural circulation system is feasible in removing the decay heat, even though some fluctuations may occur in the operation. The uneven temperature distribution in the water tank may be inevitable because convection occurs on the outside of the condensing tube besides boiling with decreasing the decay power. The instabilities in the natural circulation loop are sensitive to heat flux and system resistance rather than the water level in the steam drum and water tank. RELAP5 code shows reasonable results compared with experimental data.

  1. Evaluating the financial efficiency of energy and water saving installations in passive house

    Science.gov (United States)

    Stec, Agnieszka; Mazur, Aleksandra; Słyś, Daniel

    2017-11-01

    The article contains the outcomes of the Life Cycle Cost analysis for alternative energy and water sources utilized in passive buildings. The solutions taken into account included: heat pumps, solar collectors, photovoltaic panels, Drain Water Heat Recovery units, Rain Water Harvesting Systems and Greywater Recycling Systems. In addition, air pollution emission reduction was also calculated for all the installation variants analyzed. The analysis have shown that the systems under consideration could serve as alternatives for traditional installations. Their use has resulted in reductions in the consumption of fossil fuels and natural water resources, thus contributing to environmental improvements.

  2. Evaluating the financial efficiency of energy and water saving installations in passive house

    Directory of Open Access Journals (Sweden)

    Stec Agnieszka

    2017-01-01

    Full Text Available The article contains the outcomes of the Life Cycle Cost analysis for alternative energy and water sources utilized in passive buildings. The solutions taken into account included: heat pumps, solar collectors, photovoltaic panels, Drain Water Heat Recovery units, Rain Water Harvesting Systems and Greywater Recycling Systems. In addition, air pollution emission reduction was also calculated for all the installation variants analyzed. The analysis have shown that the systems under consideration could serve as alternatives for traditional installations. Their use has resulted in reductions in the consumption of fossil fuels and natural water resources, thus contributing to environmental improvements.

  3. Preliminary Analysis on Heat Removal Capacity of Passive Air-Water Combined Cooling Heat Exchanger Using MARS

    International Nuclear Information System (INIS)

    Kim, Seung-Sin; Jeon, Seong-Su; Hong, Soon-Joon; Bae, Sung-Won; Kwon, Tae-Soon

    2015-01-01

    Current design requirement for working time of PAFS heat exchanger is about 8 hours. Thus, it is not satisfied with the required cooling capability for the long term SBO(Station Black-Out) situation that is required to over 72 hours cooling. Therefore PAFS is needed to change of design for 72 hours cooling. In order to acquirement of long terms cooling using PAFS, heat exchanger tube has to be submerged in water tank for long time. However, water in the tank is evaporated by transferred heat from heat exchanger tubes, so water level is gradually lowered as time goes on. The heat removal capacity of air cooling heat exchanger is core parameter that is used for decision of applicability on passive air-water combined cooling system using PAFS in long term cooling. In this study, the development of MARS input model and plant accident analysis are performed for the prediction of the heat removal capacity of air cooling heat exchanger. From analysis result, it is known that inflow air velocity is the decisive factor of the heat removal capacity and predicted air velocity is lower than required air velocity. But present heat transfer model and predicted air velocity have uncertainty. So, if changed design of PAFS that has over 4.6 kW heat removal capacity in each tube, this type heat exchanger can be applied to long term cooling of the nuclear power plant

  4. Passive body heating improves sleep patterns in female patients with fibromyalgia

    Directory of Open Access Journals (Sweden)

    Andressa Silva

    2013-01-01

    Full Text Available OBJECTIVE: To assess the effect of passive body heating on the sleep patterns of patients with fibromyalgia. METHODS: Six menopausal women diagnosed with fibromyalgia according to the criteria determined by the American College of Rheumatology were included. All women underwent passive immersion in a warm bath at a temperature of 36 ±1 °C for 15 sessions of 30 minutes each over a period of three weeks. Their sleep patterns were assessed by polysomnography at the following time-points: pre-intervention (baseline, the first day of the intervention (acute, the last day of the intervention (chronic, and three weeks after the end of the intervention (follow-up. Core body temperature was evaluated by a thermistor pill during the baseline, acute, chronic, and follow-up periods. The impact of this treatment on fibromyalgia was assessed via a specific questionnaire termed the Fibromyalgia Impact Questionnaire. RESULTS: Sleep latency, rapid eye movement sleep latency and slow wave sleep were significantly reduced in the chronic and acute conditions compared with baseline. Sleep efficiency was significantly increased during the chronic condition, and the awakening index was reduced at the chronic and follow-up time points relative to the baseline values. No significant differences were observed in total sleep time, time in sleep stages 1 or 2 or rapid eye movement sleep percentage. The core body temperature and Fibromyalgia Impact Questionnaire responses did not significantly change over the course of the study. CONCLUSION: Passive body heating had a positive effect on the sleep patterns of women with fibromyalgia.

  5. Passive body heating improves sleep patterns in female patients with fibromyalgia

    Science.gov (United States)

    Silva, Andressa; de Queiroz, Sandra Souza; Andersen, Monica Levy; Mônico-Neto, Marcos; da Silveira Campos, Raquel Munhoz; Roizenblatt, Suely; Tufik, Sergio; de Mello, Marco Túlio

    2013-01-01

    OBJECTIVE: To assess the effect of passive body heating on the sleep patterns of patients with fibromyalgia. METHODS: Six menopausal women diagnosed with fibromyalgia according to the criteria determined by the American College of Rheumatology were included. All women underwent passive immersion in a warm bath at a temperature of 36±1°C for 15 sessions of 30 minutes each over a period of three weeks. Their sleep patterns were assessed by polysomnography at the following time-points: pre-intervention (baseline), the first day of the intervention (acute), the last day of the intervention (chronic), and three weeks after the end of the intervention (follow-up). Core body temperature was evaluated by a thermistor pill during the baseline, acute, chronic, and follow-up periods. The impact of this treatment on fibromyalgia was assessed via a specific questionnaire termed the Fibromyalgia Impact Questionnaire. RESULTS: Sleep latency, rapid eye movement sleep latency and slow wave sleep were significantly reduced in the chronic and acute conditions compared with baseline. Sleep efficiency was significantly increased during the chronic condition, and the awakening index was reduced at the chronic and follow-up time points relative to the baseline values. No significant differences were observed in total sleep time, time in sleep stages 1 or 2 or rapid eye movement sleep percentage. The core body temperature and Fibromyalgia Impact Questionnaire responses did not significantly change over the course of the study. CONCLUSION: Passive body heating had a positive effect on the sleep patterns of women with fibromyalgia. PMID:23525306

  6. Heat-rejection design for large concentrating solar arrays

    Science.gov (United States)

    French, E. P.

    1980-01-01

    This paper considers the effect of heat rejection devices (radiators) on the performance and cost of large concentrating solar arrays for space application. Overall array characteristics are derived from the weight, cost, and performance of four major components; namely primary structure, optics/secondary structure, radiator, and solar panel. An ideal concentrator analysis is used to establish general cost and performance trends independent of specific array design. Both passive and heat-pipe radiation are evaluated, with an incremental cost-of-power approach used in the evaluation. Passive radiators are found to be more cost effective with silicon than with gallium arsenide (GaAs) arrays. Representative concentrating arrays have been evaluated for both near-term and advanced solar cell technology. Minimum cost of power is achieved at geometric concentration ratios in the range 2 to 6.

  7. A passive decay-heat removal system for an ABWR based on air cooling

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, Hiroyasu, E-mail: mochizki@u-fukui.ac.jp [Research Institute of Nuclear Engineering, University of Fukui, 1-2-4 Kanawa-cho, Tsuruga, Fukui 914-0055 (Japan); Yano, Takahiro [School of Engineering, University of Fukui, 1-2-4 Kanawa-cho, Tsuruga, Fukui 914-0055 (Japan)

    2017-01-15

    Highlights: • A passive decay heat removal system for an ABWR is discussed using combined system of the reactor and an air cooler. • Effect of number of pass of the finned heat transfer tubes on heat removal is investigated. • The decay heat can be removed by air coolers with natural convection. • Two types of air cooler are evaluated, i.e., steam condensing and water cooling types. • Measures how to improve the heat removal rate and to make compact air cooler are discussed. - Abstract: This paper describes the capability of an air cooling system (ACS) operated under natural convection conditions to remove decay heat from the core of an Advanced Boiling Water Reactor (ABWR). The motivation of the present research is the Fukushima Severe Accident (SA). The plant suffered damages due to the tsunami and entered a state of Station Blackout (SBO) during which seawater cooling was not available. To prevent this kind of situation, we proposed a passive decay heat removal system (DHRS) in the previous study. The plant behavior during the SBO was calculated using the system code NETFLOW++ assuming an ABWR with the ACS. However, decay heat removal under an air natural convection was difficult. In the present study, a countermeasure to increase heat removal rate is proposed and plant transients with the ACS are calculated under natural convection conditions. The key issue is decreasing pressure drop over the tube banks in order to increase air flow rate. The results of the calculations indicate that the decay heat can be removed by the air natural convection after safety relief valves are actuated many times during a day. Duct height and heat transfer tube arrangement of the AC are discussed in order to design a compact and efficient AC for the natural convection mode. As a result, a 4-pass heat transfer tubes with 2-row staggered arrangement is the candidate of the AC for the DHRS under the air natural convection conditions. The heat removal rate is re-evaluated as

  8. Passive Decay Heat Removal System Options for S-CO2 Cooled Micro Modular Reactor

    International Nuclear Information System (INIS)

    Moon, Jangsik; Jeong, Yong Hoon; Lee, Jeong Ik

    2014-01-01

    To achieve modularization of whole reactor system, Micro Modular Reactor (MMR) which has been being developed in KAIST took S-CO 2 Brayton power cycle. The S-CO 2 power cycle is suitable for SMR due to high cycle efficiency, simple layout, small turbine and small heat exchanger. These characteristics of S-CO 2 power cycle enable modular reactor system and make reduced system size. The reduced size and modular system motived MMR to have mobility by large trailer. Due to minimized on-site construction by modular system, MMR can be deployed in any electricity demand, even in isolated area. To achieve the objective, fully passive safety systems of MMR were designed to have high reliability when any offsite power is unavailable. In this research, the basic concept about MMR and Passive Decay Heat Removal (PDHR) system options for MMR are presented. LOCA, LOFA, LOHS and SBO are considered as DBAs of MMR. To cope with the DBAs, passive decay heat removal system is designed. Water cooled PDHR system shows simple layout, but has CCF with reactor systems and cannot cover all DBAs. On the other hand, air cooled PDHR system with two-phase closed thermosyphon shows high reliability due to minimized CCF and is able to cope with all DBAs. Therefore, the PDHR system of MMR will follows the air-cooled PDHR system and the air cooled system will be explored

  9. Safety analysis of increase in heat removal from reactor coolant system with inadvertent operation of passive residual heat removal at no load conditions

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Ge; Cao, Xuewu [School of Mechanical and Engineering, Shanghai Jiao Tong University, Shanghai (China)

    2015-06-15

    The advanced passive pressurized water reactor (PWR) is being constructed in China and the passive residual heat removal (PRHR) system was designed to remove the decay heat. During accident scenarios with increase of heat removal from the primary coolant system, the actuation of the PRHR will enhance the cooldown of the primary coolant system. There is a risk of power excursion during the cooldown of the primary coolant system. Therefore, it is necessary to analyze the thermal hydraulic behavior of the reactor coolant system (RCS) at this condition. The advanced passive PWR model, including major components in the RCS, is built by SCDAP/RELAP5 code. The thermal hydraulic behavior of the core is studied for two typical accident sequences with PRHR actuation to investigate the core cooling capability with conservative assumptions, a main steam line break (MSLB) event and inadvertent opening of a steam generator (SG) safety valve event. The results show that the core is ultimately shut down by the boric acid solution delivered by Core Makeup Tank (CMT) injections. The effects of CMT boric acid concentration and the activation delay time on accident consequences are analyzed for MSLB, which shows that there is no consequential damage to the fuel or reactor coolant system in the selected conditions.

  10. Numerical Study on the Design Concept of an Air-Cooled Condensation Heat Exchanger in a Long-term Passive Cooling System

    International Nuclear Information System (INIS)

    Kim, Myoung Jun; Moon, Joo Hyung; Bae, Youngmin; Kim, Young In; Park, Hyun Sik; Lee, Hee Joon

    2016-01-01

    SMART is the only licensed SMR in the world since the Nuclear Safety and Security Commission (NSSC) issued officially the Standard Design Approval (SDA) on 4 July 2012. Recently, the pre-project engineering (PPE) was officially launched for the construction of SMART and developing human resources capability. Both KAERI and King Abdullah City for Atomic and Renewable Energy (K.A. CARE) will conduct a three-year preliminary study to review the feasibility of building SMART and to prepare for its commercialization. SMART is equipped with passive cooling systems in order to enhance the safety of the reactor. The PRHRS (Passive Residual Heat Removal System) is the major passive safety system, which is actuated after an accident to remove the residual heat and the sensible heat from the RCS (Reactor Coolant System) through the steam generators (SGs) until the safe shutdown condition is reached. In this study, condensing heat transfer correlations in TSCON were validated using experimental data. It was shown that most of the condensation correlation gave satisfactory predictions of the cooling capacity of an-air cooled condensation heat exchanger

  11. Numerical Study on the Design Concept of an Air-Cooled Condensation Heat Exchanger in a Long-term Passive Cooling System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myoung Jun; Moon, Joo Hyung; Bae, Youngmin; Kim, Young In; Park, Hyun Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Hee Joon [Kookmin University, Seoul (Korea, Republic of)

    2016-10-15

    SMART is the only licensed SMR in the world since the Nuclear Safety and Security Commission (NSSC) issued officially the Standard Design Approval (SDA) on 4 July 2012. Recently, the pre-project engineering (PPE) was officially launched for the construction of SMART and developing human resources capability. Both KAERI and King Abdullah City for Atomic and Renewable Energy (K.A. CARE) will conduct a three-year preliminary study to review the feasibility of building SMART and to prepare for its commercialization. SMART is equipped with passive cooling systems in order to enhance the safety of the reactor. The PRHRS (Passive Residual Heat Removal System) is the major passive safety system, which is actuated after an accident to remove the residual heat and the sensible heat from the RCS (Reactor Coolant System) through the steam generators (SGs) until the safe shutdown condition is reached. In this study, condensing heat transfer correlations in TSCON were validated using experimental data. It was shown that most of the condensation correlation gave satisfactory predictions of the cooling capacity of an-air cooled condensation heat exchanger.

  12. Advanced phase change materials and systems for solar passive heating and cooling of residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Salyer, I.O.; Sircar, A.K.; Dantiki, S.

    1988-01-01

    During the last three years under the sponsorship of the DOE Solar Passive Division, the University of Dayton Research Institute (UDRI) has investigated four phase change material (PCM) systems for utility in thermal energy storage for solar passive heating and cooling applications. From this research on the basis of cost, performance, containment, and environmental acceptability, we have selected as our current and most promising series of candidate phase change materials, C-15 to C-24 linear crystalline alkyl hydrocarbons. The major part of the research during this contract period was directed toward the following three objectives. Find, test, and develop low-cost effective phase change materials (PCM) that melt and freeze sharply in the comfort temperature range of 73--77{degree}F for use in solar passive heating and cooling of buildings. Define practical materials and processes for fire retarding plasterboard/PCM building products. Develop cost-effective methods for incorporating PCM into building construction materials (concrete, plasterboard, etc.) which will lead to the commercial manufacture and sale of PCM-containing products resulting in significant energy conservation.

  13. The effect of passive heating on heat shock protein 70 and interleukin-6: a possible treatment tool for metabolic diseases?

    OpenAIRE

    Faulkner, SH; Jackson, S; Fatania, G; Leicht, CA

    2017-01-01

    Exercise and physical activity remain the gold standard methods of enhancing and maintaining health and wellbeing. However, in populations that benefit most from exercise, adherence is often poor and alternatives to exercise are important to bring about health improvements. Recent work suggests a role for passive heating (PH) and heat shock proteins (HSP) in improving cardio-metabolic health. The aim of this study was to investigate the expression of HSP70 and IL-6 in response to either exerc...

  14. Application of grey model on analyzing the passive natural circulation residual heat removal system of HTR-10

    Institute of Scientific and Technical Information of China (English)

    ZHOU Tao; PENG Changhong; WANG Zenghui; WANG Ruosu

    2008-01-01

    Using the grey correlation analysis, it can be concluded that the reactor pressure vessel wall temperature has the strongest effect on the passive residual heat removal system in HTR (High Temperature gas-cooled Reactor),the chimney height takes the second place, and the influence of inlet air temperature of the chimney is the least. This conclusion is the same as that analyzed by the traditional method. According to the grey model theory, the GM(1,1) and GM(1, 3) model are built based on the inlet air temperature of chimney, pressure vessel temperature and the chimney height. Then the effect of three factors on the heat removal power is studied in this paper. The model plays an important role on data prediction, and is a new method for studying the heat removal power. The method can provide a new theoretical analysis to the passive residual heat removal system of HTR.

  15. Evaluation of Heat Removal Performance of Passive Decay Heat Removal system for S-CO{sub 2} Cooled Micro Modular Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jangsik; Lee, Jeong Ik; Jeong, Yong Hoon [KAIST, Daejeon (Korea, Republic of)

    2015-05-15

    The modular systems is able to be transported by large trailer. Moreover, dry cooling system is applied for waste heat removal. The characteristics of MMR takes wide range of construction area from coast to desert, isolated area and disaster area. In MMR, Passive decay heat removal system (PDHRS) is necessary for taking the advantage on selection of construction area where external support cannot be offered. The PDHRS guarantees to protect MMR without external support. In this research, PDHRS of MMR is introduced and decay heat removal performance is analyzed. The PDHRS guarantees integrity of reactor coolant system. The high level of decay heat (2 MW) can be removed by PDHRS without offsite power.

  16. Passive annual heat storage principles in earth sheltered housing, a supplementary energy saving system in residential housing

    Energy Technology Data Exchange (ETDEWEB)

    Anselm, Akubue Jideofor [Green Architecture Department, School of Architecture and Urban Planning, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2008-07-01

    This paper looks through the many benefits of earth not only as a building element in its natural form but as a building mass, energy pack and spatial enclosure which characterized by location, unique physical terrain and climatic factors can be utilized in developing housing units that will provide the needed benefits of comfort alongside the seasons. Firstly the study identifies existing sunken earth houses in the North-west of China together with identifying the characters that formed the ideas behind the choice of going below the ground. Secondly, the study examines the pattern of heat exchange, heat gains and losses as to identify the principles that makes building in earth significant as an energy conservation system. The objective of this, is to relate the ideas of sunken earth home design with such principles as the passive annual heat storage systems (PAHS) in producing houses that will serve as units used to collect free solar heat all summer and cools passively while heating the earth around it and also keeping warm in winter by retrieving heat from the soil while utilizing the free solar heat stored throughout the summer as a year-round natural thermal resource. (author)

  17. Design of Passive Decay Heat Removal System using Mercury Thermosyphon for SFR

    Energy Technology Data Exchange (ETDEWEB)

    You, Byung Hyun; Jeong, Yong Hoon [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2013-10-15

    In this study, thermosyphon application is suggested to accomplish the fully passive safety grade system and compactness of components via enhance the heat removal performance. A two-phase evaporating thermosyphon operates when the evaporator is heated, the working fluid start boiling, the vapor that is formed moves to the condenser, where it is condensed on the walls, giving up the heat of phase change to the cooling fluid. Gravity forces cause the condensate to condensed liquid flow to the evaporator again. These processes occur continuously, which causes transfer of heat from evaporator to condenser vice versa. After the thermal design and performance evaluation, the results were compared with the performance of conventional DRACS system. For the same amount of decay heat removal performance of PDRC system of KALIMER-600 mercury thermosyphon system can archive around 30∼50% of compactness. For the detailed design, improved analytical model and experimental data for the validation will be required to specify the new DHR system.

  18. Simulation of Solar Heat Pump Dryer Directly Driven by Photovoltaic Panels

    Science.gov (United States)

    Houhou, H.; Yuan, W.; Wang, G.

    2017-05-01

    This paper investigates a new type of solar heat pump dryer directly driven by photovoltaic panels. In order to design this system, a mathematical model has been established describing the whole drying process, including models of key components and phenomena of heat and mass transfer at the product layer and the air. The results of simulation at different drying air temperatures and velocities have been calculated and it indicate that the temperature of drying air is crucial external parameter compared to the velocity, with the increase of drying temperature from 45°C to 55°C, the product moisture content (Kg water/Kg dry product) decreased from 0.75 Kg/Kg to 0.3 Kg/Kg.

  19. 2.5 MWT Heat Exchanger Designs for Passive DHRS in PGSFR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dehee; Eoh, Jaehyuk; Lee, Tae-Ho [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Decay Heat Removal System (DHRS) of PGSFR consists of two passive DHRS (PDHRS) trains and two active DHRS (ADHRS) trains. Recently, total heat removal capacity of the DHRS in the PGSFR has increased to 10 MWT from 4 MWT reflecting safety analysis results. Consequently, DHRS components including heat exchangers, dampers, electro-magnetic pump, fan, piping, expansion tank and stack have been newly designed. In this work, physical models and correlations to design two main components of the PDHRS, decay heat exchanger (DHX) and natural-draft sodium-to-air heat exchanger (AHX), are introduced and designed data are presented. Physical models and correlations applied for heat exchangers in the PDHRS design were introduced and design works using the SHXSA and AHXSA codes has been completed for 2.5 MWT decay heat removal capability. DHX and AHX are designed utilizing SHXSA and AHXSA codes, respectively. Those design codes have capability of thermal sizing and performance analysis for the shell-and-tube type and counter-current flow heat exchanger unit. Since both SHXSA and AHXSA codes are similar, following description is focused on the SHXSA code. A single flow channel associated with an individual heat transfer tube is basically considered for thermal sizing and then the calculation results and design variables regarding heat transfer and pressure drop, etc. are extended to whole tubes. Various correlations of heat transfer and pressure loss for the shell- and tubeside flows were implemented in the computer codes. The analysis domain is discretized into several control volumes and heat transfer and pressure losses are calculated in each control volume.

  20. The Polyvalent Heat Supply System for Experimental Building of the Passive Type (area of 300 m2 Based on Renewable and Alternative Energy Sources

    Directory of Open Access Journals (Sweden)

    Basok, B.I.

    2014-11-01

    Full Text Available Results of the development and implementation of heat supply system for experimental building of the passive type are presented, optimal operating conditions are investigated, guidelines for the creation of heat supply systems for passive type buildings are provided.

  1. Analysis and Modeling of Heat Generation in Overcharged Li-Ion Battery with Passive Cooling

    DEFF Research Database (Denmark)

    Coman, Paul Tiberiu; Veje, Christian

    2013-01-01

    This paper presents a dynamic model for simulating the heat generation in Lithium batteries and an investigation of the heat transfer as well as the capacity of Phase Change Materials (PCM’s) to store energy inside a battery cell module when the battery is overcharged. The study is performed......-cooled and passively cooled using a PCM, respectively. As expected, the results show that for high currents, the heat generation and implicitly the temperature increases. However, using a PCM the temperature increase is found to be limited allowing the battery to be overcharged to a certain degree. It is found...

  2. Passive flow heat exchanger simulation for power generation from solar pond using thermoelectric generators

    Science.gov (United States)

    Baharin, Nuraida'Aadilia; Arzami, Amir Afiq; Singh, Baljit; Remeli, Muhammad Fairuz; Tan, Lippong; Oberoi, Amandeep

    2017-04-01

    In this study, a thermoelectric generator heat exchanger system was designed and simulated for electricity generation from solar pond. A thermoelectric generator heat exchanger was studied by using Computational Fluid Dynamics to simulate flow and heat transfer. A thermoelectric generator heat exchanger designed for passive in-pond flow used in solar pond for electrical power generation. A simple analysis simulation was developed to obtain the amount of electricity generated at different conditions for hot temperatures of a solar pond at different flow rates. Results indicated that the system is capable of producing electricity. This study and design provides an alternative way to generate electricity from solar pond in tropical countries like Malaysia for possible renewable energy applications.

  3. Passive solar technology

    Energy Technology Data Exchange (ETDEWEB)

    Watson, D

    1981-04-01

    The present status of passive solar technology is summarized, including passive solar heating, cooling and daylighting. The key roles of the passive solar system designer and of innovation in the building industry are described. After definitions of passive design and a summary of passive design principles are given, performance and costs of passive solar technology are discussed. Passive energy design concepts or methods are then considered in the context of the overall process by which building decisions are made to achieve the integration of new techniques into conventional design. (LEW).

  4. Effect of heat treatment conditions on the passivation behavior of WE43C Mg–Y–Nd alloy in chloride containing alkaline environments

    Directory of Open Access Journals (Sweden)

    Jakraphan Ninlachart

    2017-06-01

    Full Text Available Mg–Y–Nd alloy (WE43C or Elektron 43 is a heat treatable magnesium wrought alloy that can be used up to 250 °C for aerospace application. This alloy has excellent mechanical properties (UTS: up to 345 MPa at room temperature and improved corrosion resistance. Electrochemical passivation studies were conducted on this alloy under different heat treatment conditions in 0.1 M NaOH solution with the addition of chloride from 0 to 1000 ppm. The passive potential range typically extended to more than 1.5 VAg/AgCl. The transpassive potential was not dependent on the heat treatment condition of the alloy when the chloride concentration increased up to 500 ppm. However, pitting protection potential varied with the heat treatment condition when the chloride addition was 500 ppm or more. The specimen surface was analyzed using scanning electron microscopy (SEM, X-ray diffraction (XRD, X-ray photoelectron spectroscopy (XPS, and Raman spectroscopy to understand the passivation behavior of this alloy. The passivated surface of the WE43C specimens indicated that the surface layer consisted of MgO, Mg(OH2, and rare earth oxide phases, and the heat treatment conditions did not significantly affect the composition of the surface film.

  5. Progress in the design of Normal Heat Flux First Wall panels for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Cicero, Tindaro, E-mail: Tindaro.Cicero@f4e.europa.eu [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Jimenez, Marc; D’Amico, Gabriele; Pou, Jordi Ayneto; Dellopoulos, Georges; Alvaro, Elena; Cardenes, Sabas; Banetta, Stefano; Bellin, Boris; Zacchia, Francesco [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Calcagno, Barbara; Chappuis, Philippe; Gicquel, Stefan; Mitteau, Raphael; Raffray, Rene [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St., Paul Lez Durance Cedex (France)

    2015-10-15

    Highlights: • Improved detail design of several NHF FW panels for ITER. • Implemented design solutions to improve the manufacturing of NHF FW panels. • Performed FEM simulations for the overall assessment of NHF FW panels. • Performed detailed analyses for integration of diagnostics in the NHF FW panels. - Abstract: A typical NHF FW panel consists of a series of fingers, which represent the elementary plasma facing units and are designed to withstand 15,000 cycles at 2 MW/m{sup 2}. The fingers are mechanically joined and supported by a back structural element or “supporting beam”. The structure of a finger is made of three different materials: stainless steel for the supporting structure, copper chromium zirconium for the heat sink, and beryllium as armour material. Due to their location and to the interfaces with other systems (e.g. Diagnostics, Remote Handling), the NHF FW panels are divided in different main and minor variants. The aim of this paper is to present the design work performed towards the PA signature. CAD detailed models have been created in CATIA for main and minor variants. Examples of local design solutions, as well as design work to achieve the global configuration of specific modules are provided. Finite Element (FE) analyses have been carried out, in order to simulate the operational scenario of ITER and assess the thermo-mechanical behaviour of the most important FW panels against the required design criteria. This design and analyses activity is required to progress towards the finalization of the detailed design of the NHF FW main and minor variants.

  6. Progress in the design of Normal Heat Flux First Wall panels for ITER

    International Nuclear Information System (INIS)

    Cicero, Tindaro; Jimenez, Marc; D’Amico, Gabriele; Pou, Jordi Ayneto; Dellopoulos, Georges; Alvaro, Elena; Cardenes, Sabas; Banetta, Stefano; Bellin, Boris; Zacchia, Francesco; Calcagno, Barbara; Chappuis, Philippe; Gicquel, Stefan; Mitteau, Raphael; Raffray, Rene

    2015-01-01

    Highlights: • Improved detail design of several NHF FW panels for ITER. • Implemented design solutions to improve the manufacturing of NHF FW panels. • Performed FEM simulations for the overall assessment of NHF FW panels. • Performed detailed analyses for integration of diagnostics in the NHF FW panels. - Abstract: A typical NHF FW panel consists of a series of fingers, which represent the elementary plasma facing units and are designed to withstand 15,000 cycles at 2 MW/m"2. The fingers are mechanically joined and supported by a back structural element or “supporting beam”. The structure of a finger is made of three different materials: stainless steel for the supporting structure, copper chromium zirconium for the heat sink, and beryllium as armour material. Due to their location and to the interfaces with other systems (e.g. Diagnostics, Remote Handling), the NHF FW panels are divided in different main and minor variants. The aim of this paper is to present the design work performed towards the PA signature. CAD detailed models have been created in CATIA for main and minor variants. Examples of local design solutions, as well as design work to achieve the global configuration of specific modules are provided. Finite Element (FE) analyses have been carried out, in order to simulate the operational scenario of ITER and assess the thermo-mechanical behaviour of the most important FW panels against the required design criteria. This design and analyses activity is required to progress towards the finalization of the detailed design of the NHF FW main and minor variants.

  7. Heat exchanger for cooling a liquid metal with air, including panels of identical tubes

    International Nuclear Information System (INIS)

    Malaval, C.

    1985-01-01

    The heat exchanger includes panels of identical tubes, each one comprising two horizontal collectors situated at the vertical of each other and a group of vertical tubes for cooling arranged in a horizontal parallelepiped casing opened on two of its opposite sides. The air flows from the inlet to the outlet face of the casing. The panels of tubes are arranged side by side so that their outlet faces form a prismatic surface of which the height is vertical and the inner space communicates with a vertical axis chimney. Each one of the panels is hanging from a fixed structure by means of articulated fasteners, by means of its upper collector only. The invention applies, more particularly, for cooling the primary sodium of fast neutron reactors after they are stopped [fr

  8. Improved Design Concept for ensuring the Passive Decay Heat Removal Performance of an SFR

    International Nuclear Information System (INIS)

    Eoh, Jae Hyuk; Lee, Tae Ho; Han, Ji Woong; Kim, Seong O

    2011-01-01

    In order to enhance the operational reliability of a purely passive decay heat removal system in KALIMER, which is named as PDRC, three design options to prevent a sodium freezing in an intermediate decay heat removal circuit were proposed, and their feasibilities was quantitatively evaluated. For all the options, more specific design considerations were made to confirm their feasibility to properly materialize their concepts in a practical system design procedure, and the general definitions for a purely passive concept and its design features have been discussed. A numerical study to evaluate the coastdown flow effect of the primary pump was performed to figure out the early stage DHR capability inside reactor pool during a loss of normal heat sink accident. The thermal-hydraulic calculations have been made by using the COMMIX-1AR/P code, and it was found that the initiation of heat removal by DHX could be accelerated by the increase of the coastdown time but it needs a large-sized flywheel. For the demonstration of the innovative concept, a large scale sodium thermal-hydraulic test facility is currently being designed. It is very difficult to reproduce both a hydrodynamic and a thermodynamic similarity to the prototype plant if the thermal driving head is determined by structure-to-fluid heat transfer under natural circulation flow. Hence the similitude requirements for the sodium thermal-hydraulic test facility employing natural convection heat transfer were developed, and the preliminary design data of the test facility by implementing proper scaling methodologies was produced. The design restrictions imposed on the test facility and the scaling distortions of the design data to the full-scale system were also discussed

  9. Possible design of PBR for passive decay heat removal

    International Nuclear Information System (INIS)

    Sambuu, Odmaa; Obara, Toru

    2016-01-01

    Conditions for design parameters of above-ground and underground, prismatic high-temperature gas-cooled reactor (HTGR)s for passive decay heat removal based on fundamental heat transfer mechanisms were obtained in the previous works. In the present study, analogous conditions were obtained for pebble bed reactors by performing the same procedure using the model for heat transfer in porous media of COMSOL 4.3a software, and the results were compared. For the power density profile, several approximated distributions together with original one throughout the 10-MWt high-temperature gas-cooled reactor-test module (HTR-10) were used, and it was found that an HTR-10 with a uniform power density profile has the higher safety margin than those with other profiles. In other words, the safety features of a PBR can be enhanced by flattening the power density profile. We also found that a prismatic HTGR with a uniform power density profile throughout the core has a greater safety margin than a PBR with the same design characteristics. However, when the power density profile is not flattened during the operation, the PBR with the linear power density profile has more safety margin than the prismatic HTGR with the same design parameters and with the power density profile by cosine and Bessel functions. (author)

  10. Evaluation of conceptual Heat Exchanger Design for passive containment cooling system of SMART

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min-Ki; Hong, Soon Joon [FNC Tech., Yongin (Korea, Republic of); Kim, Young In; Kim, Seok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    PCCS(Passive containment cooling system) is the passive safety system which ultimately removes the reactor decay heat. Cooling performance of the air-cooled type and water-circulation cooling type of PCCS were analyzed using CAP version 2.21. The analysis results show the water-circulation cooling PCCS is more effective in lowering the peak pressure and temperature in the containment building. However, the air-cooled PCCS is more effective to the long-term cooling. From this study, the efficiency evaluation results for the two PCCS designs are obtained. These results may be applied in the PCCS design improvement. Moreover, these results will be used as a reference for the later PCCS design and analysis.

  11. Development and testing of passive autocatalytic recombiners cooled by heat pipes; Entwicklung und Erprobung mittels Heatpipe gekuehlter katalytischer Rekombinatoren

    Energy Technology Data Exchange (ETDEWEB)

    Granzow, Christoph

    2012-11-26

    A severe accident in a nuclear power plant (NPP) can lead to core damage in conjunction with the release of large amounts of hydrogen. As hydrogen mitigation measure, passive autocatalytic recombiners (PARs) are used in today's pressurized water reactors. PARs recombine hydrogen and oxygen contained in the air to steam. The heat from this exothermic reaction causes the catalyst and its surroundings to heat up. If parts of the PAR heat up above the ignition temperature of the gas mixture, a spontaneous deflagration or detonation can occur. The aim of this work is the prevention of such high temperatures by means of passive cooling of the catalyst with heat pipes. Heat pipes are completely passive heat exchanger with a very high effective thermal conductivity. For a deeper understanding of the reaction kinetics at lower temperatures, single catalytic coated heat pipes are studied in a flow reactor. The development of a modular small-scale PAR model is then based on a test series with cooled catalyst sheets. Finally, the PAR model is tested inside a pressure vessel under boundary conditions similar to a real NPP. The experiments show, that the temperatures of the cooled catalytic sheets stay significantly below the temperature of the uncooled sheets and below the ignition temperature of the gas mixture under any set boundary conditions, although no significant reduction of the conversion efficiency can be observed. As a last point, a mathematical model of the reaction kinetics of the recombination process as well as a model of the fluid dynamic and thermohydraulic processes in a heat pipe are developed with the data obtained from the experiments.

  12. Analytical and experimental analysis of a low-pressure heat exchanger suitable for passive ventilation

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2011-01-01

    AbstractA core element in sustainable ventilation systems is the heat recovery system. Conventional heat recovery systems have a high pressure drop that acts as blockage to naturally driven airflow. The heat recovery system we propose here consists of two separated air-to-liquid heat exchangers...... interconnected by a liquid loop powered by a pump ideal as a component in a heat recovery system for passive ventilation systems. This paper describes the analytical framework and the experimental development of one exchanger in the liquid-loop. The exchanger was constructed from the 8mm plastic tubing...... that is commonly used in water-based floor-heating systems. The pressure loss and temperature exchange efficiency was measured. For a design airflow rate of 560L/s, the pressure loss was 0.37Pa and the efficiency was 75.6%. The experimental results agree well with the literature or numerical fluid calculations...

  13. Numerical analysis of air flow, heat transfer, moisture transport and thermal comfort in a room heated by two-panel radiators

    Energy Technology Data Exchange (ETDEWEB)

    Sevilgen, Goekhan; Kilic, Muhsin [Uludag University, Faculty of Engineering and Architecture, Department of Mechanical Engineering, TR-16059 Bursa (Turkey)

    2011-01-15

    A three-dimensional steady-state numerical analysis was performed in a room heated by two-panel radiators. A virtual sitting manikin with real dimensions and physiological shape was added to the model of the room, and it was assumed that the manikin surfaces were subjected to constant temperature. Two different heat transfer coefficients for the outer wall and for the window were considered. Heat interactions between the human body surfaces and the room environment, the air flow, the temperature, the humidity, and the local heat transfer characteristics of the manikin and the room surfaces were computed numerically under different environmental conditions. Comparisons of the results are presented and discussed. The results show that energy consumption can be significantly reduced while increasing the thermal comfort by using better-insulated outer wall materials and windows. (author)

  14. Demonstration of Passive Fuel Cell Thermal Management Technology

    Science.gov (United States)

    Burke, Kenneth A.; Jakupca, Ian; Colozza, Anthony; Wynne, Robert; Miller, Michael; Meyer, Al; Smith, William

    2012-01-01

    The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA Exploration program. The passive thermal management system relies on heat conduction within highly thermally conductive cooling plates to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack. Using the passive approach eliminates the need for a coolant pump and other cooling loop components within the fuel cell system which reduces mass and improves overall system reliability. Previous development demonstrated the performance of suitable highly thermally conductive cooling plates and integrated heat exchanger technology to collect the heat from the cooling plates (Ref. 1). The next step in the development of this passive thermal approach was the demonstration of the control of the heat removal process and the demonstration of the passive thermal control technology in actual fuel cell stacks. Tests were run with a simulated fuel cell stack passive thermal management system outfitted with passive cooling plates, an integrated heat exchanger and two types of cooling flow control valves. The tests were run to demonstrate the controllability of the passive thermal control approach. Finally, successful demonstrations of passive thermal control technology were conducted with fuel cell stacks from two fuel cell stack vendors.

  15. JTEC panel on display technologies in Japan

    Science.gov (United States)

    Tannas, Lawrence E., Jr.; Glenn, William E.; Credelle, Thomas; Doane, J. William; Firester, Arthur H.; Thompson, Malcolm

    1992-01-01

    This report is one in a series of reports that describes research and development efforts in Japan in the area of display technologies. The following are included in this report: flat panel displays (technical findings, liquid crystal display development and production, large flat panel displays (FPD's), electroluminescent displays and plasma panels, infrastructure in Japan's FPD industry, market and projected sales, and new a-Si active matrix liquid crystal display (AMLCD) factory); materials for flat panel displays (liquid crystal materials, and light-emissive display materials); manufacturing and infrastructure of active matrix liquid crystal displays (manufacturing logistics and equipment); passive matrix liquid crystal displays (LCD basics, twisted nematics LCD's, supertwisted nematic LCD's, ferroelectric LCD's, and a comparison of passive matrix LCD technology); active matrix technology (basic active matrix technology, investment environment, amorphous silicon, polysilicon, and commercial products and prototypes); and projection displays (comparison of Japanese and U.S. display research, and technical evaluation of work).

  16. Numerical and experimental study on temperature control of solar panels with form-stable paraffin/expanded graphite composite PCM

    International Nuclear Information System (INIS)

    Luo, Zigeng; Huang, Zhaowen; Xie, Ning; Gao, Xuenong; Xu, Tao; Fang, Yutang; Zhang, Zhengguo

    2017-01-01

    Highlights: • A passive cooling PV-PCM system was developed. • Form-stable paraffin/EG composite PCM with high thermal conductivity was utilized. • Numerical simulation on the temperature of PV-PCM panel was carried out. • Effects of density were studied under the given weather conditions. - Abstract: Performance of photovoltaic (PV) panels is greatly affected by its operating temperature. And traditional active and passive cooling methods usually suffer from the disadvantages of external energy consumption, uneven temperature distribution and low thermal conductivity of phase change materials (PCMs). In this work, a PV-PCM system was developed to control the temperature of a PV panel by applying high thermal conductive form-stable paraffin (ZDJN-28)/EG composite PCM. The temperature, output voltage and power of a conventional PV panel and the PV-PCM panel were measured and compared. A numerical simulation model established by CFD software FLUENT was used to simulate the temperature change process of the PV-PCM panel with different material densities under the same conditions as experiment. The experiment results showed that compared with the temperature of the conventional PV panel, the temperature of the PV-PCM panel is kept below 50 °C for 200 min extended by 146 min with output power averagely increased by 7.28% in heating process. Simulated temperatures were in good agreement with experimental temperatures and indicated that the higher the density of the PCM is, the better the temperature management performance the PV panel could achieve. Besides, the PCM with density of 900 kg/m 3 was found sufficient to achieve a good temperature management performance when the average ambient temperature below 25 °C with the highest solar irradiation of 901 w/m 2 . In summary, this work is of great importance in the design of a PV-PCM system for temperature management of PV panels.

  17. Experimental and analytical studies on the passive residual heat removal system for the advanced integral type reactor

    International Nuclear Information System (INIS)

    Park, Hyun-Sik; Choi, Ki-Yong; Cho, Seok; Park, Choon-Kyung; Lee, Sung-Jae; Song, Chul-Hwa; Chung, Moon-Ki

    2004-01-01

    An experiment on the thermal-hydraulic characteristics of the passive residual heat removal system (PRHRS) for an advanced integral type reactor, SMART-P, has been performed, and its experimental results have been analyzed using a best-estimated system analysis code, MARS. The experiment is performed to investigate the performance of the passive residual heat removal system using the high temperature and high pressure thermal-hydraulic test facility (VISTA) which simulates the SMART-P. The natural circulation performance of the PRHRS, the heat transfer characteristics of the PRHRS heat exchangers and the emergency cooldown tank (ECT), and the thermal-hydraulic behavior of the primary loop are investigated. The experimental results show that the coolant flows steadily in the PRHRS loop and the heat transfer through the PRHRS heat exchanger in the emergency cooldown tank is sufficient enough to enable a natural circulation of the coolant. Analysis on a typical PRHRS test has been carried out using the MARS code. The overall trends of the calculated flow rate, pressure, temperature, and heat transfer rate in the PRHRS are similar to the experimental data. There is good agreement between the experimental data and the calculated one for the fluid temperature in the PRHRS steam line. However, the calculated fluid temperature in the PRHRS condensate line is higher, the calculated coolant outlet temperature is lower, and the heat transfer rate through the PRHRS heat exchanger is lower than the experimental data. It seems that it is due to an insufficient heat transfer modeling in the pool such as the emergency cooldown tank in the MARS calculation. (author)

  18. Optimum design of composite panel with photovoltaic-thermo module. Absorbing effect of cooling panel; Hikari netsu fukugo panel no saiteki sekkei. Reikyaku panel no kyunetsu koka

    Energy Technology Data Exchange (ETDEWEB)

    Sato, M; Kikuchi, S; Tani, T [Science University of Tokyo, Tokyo (Japan); Kadotani, K; Imaizumi, H [Komatsu Ltd., Tokyo (Japan)

    1996-10-27

    The composite panel with photovoltaic-thermo module becomes higher in energy-saving than the conventional air-conditioning system by the independent radiational heating and cooling effect obtained when the generating panel using a solar cell module is combined with the heating and cooling panel using a thermo-element module. The output of a solar cell module can be directly used because the solar cell module operates in AC. This paper reports the relation between the absorbed value and power consumption of the cooling panel, while paying attention to the cooling panel. The performance coefficient of the maximum absorbed value from an non-absorbing substance to a cooling panel is 2 to 3. Assume that the cooling panel during non-adiabatic operation is operated using a solar cell module of 800 W/m{sup 2} in solar intensity and 15% in conversion efficiency. The cooling-surface temperature difference is 12.12 K, and the maximum absorbed value of a non-absorbing substance to a cooling panel is 39.12 W/m{sup 2}. The absorbed value of the outer temperature to the cooling panel is 74.4 W/m{sup 2}, and each performance coefficient is 3.26 and 0.62. The absorbed value must be calculated for evaluation from the cooling-surface temperature difference measured directly from the cooling panel. 4 refs., 8 figs., 1 tab.

  19. Design of an Experimental Facility for Passive Heat Removal in Advanced Nuclear Reactors

    Science.gov (United States)

    Bersano, Andrea

    With reference to innovative heat exchangers to be used in passive safety system of Gen- eration IV nuclear reactors and Small Modular Reactors it is necessary to study the natural circulation and the efficiency of heat removal systems. Especially in safety systems, as the decay heat removal system of many reactors, it is increasing the use of passive components in order to improve their availability and reliability during possible accidental scenarios, reducing the need of human intervention. Many of these systems are based on natural circulation, so they require an intense analysis due to the possible instability of the related phenomena. The aim of this thesis work is to build a scaled facility which can reproduce, in a simplified way, the decay heat removal system (DHR2) of the lead-cooled fast reactor ALFRED and, in particular, the bayonet heat exchanger, which transfers heat from lead to water. Given the thermal power to be removed, the natural circulation flow rate and the pressure drops will be studied both experimentally and numerically using the code RELAP5 3D. The first phase of preliminary analysis and project includes: the calculations to design the heat source and heat sink, the choice of materials and components and CAD drawings of the facility. After that, the numerical study is performed using the thermal-hydraulic code RELAP5 3D in order to simulate the behavior of the system. The purpose is to run pretest simulations of the facility to optimize the dimensioning setting the operative parameters (temperature, pressure, etc.) and to chose the most adequate measurement devices. The model of the system is continually developed to better simulate the system studied. High attention is dedicated to the control logic of the system to obtain acceptable results. The initial experimental tests phase consists in cold zero power tests of the facility in order to characterize and to calibrate the pressure drops. In future works the experimental results will be

  20. Study on grey theoretical model of passive residual heat removal system

    International Nuclear Information System (INIS)

    Zhou Tao; Yang Ruichang; Su, G.H.; Jia Dounan; Sugiyama, K.

    2004-01-01

    Natural Circulation Passive Residual Heat Removal System is treated as a Grey System by taking into account of its complexity and uncertainty of effect for factors each other. The magnitude and degree of some factors are confirmed by grey incidence analysis method; The one-one relationship of some variables is built by GM (1, 1) model; The relationship between key factor and other effect factors is built (1, 4) model. Grey model shows its more advantage of precision through comparing with multivariate model. (author)

  1. Performance Evaluation of the Concept of Hybrid Heat Pipe as Passive In-core Cooling Systems for Advanced Nuclear Power Plant

    International Nuclear Information System (INIS)

    Jeong, Yeong Shin; Kim, Kyung Mo; Kim, In Guk; Bang, In Cheol

    2015-01-01

    As an arising issue for inherent safety of nuclear power plant, the concept of hybrid heat pipe as passive in-core cooling systems was introduced. Hybrid heat pipe has unique features that it is inserted in core directly to remove decay heat from nuclear fuel without any changes of structures of existing facilities of nuclear power plant, substituting conventional control rod. Hybrid heat pipe consists of metal cladding, working fluid, wick structure, and neutron absorber. Same with working principle of the heat pipe, heat is transported by phase change of working fluid inside metal cask. Figure 1 shows the systematic design of the hybrid heat pipe cooling system. In this study, the concept of a hybrid heat pipe was introduced as a Passive IN-core Cooling Systems (PINCs) and demonstrated for internal design features of heat pipe containing neutron absorber. Using a commercial CFD code, single hybrid heat pipe model was analyzed to evaluate thermal performance in designated operating condition. Also, 1-dimensional reactor transient analysis was done by calculating temperature change of the coolant inside reactor pressure vessel using MATLAB. As a passive decay heat removal device, hybrid heat pipe was suggested with a concept of combination of heat pipe and control rod. Hybrid heat pipe has distinct feature that it can be a unique solution to cool the reactor when depressurization process is impossible so that refueling water cannot be injected into RPV by conventional ECCS. It contains neutron absorber material inside heat pipe, so it can stop the reactor and at the same time, remove decay heat in core. For evaluating the concept of hybrid heat pipe, its thermal performance was analyzed using CFD and one-dimensional transient analysis. From single hybrid heat pipe simulation, the hybrid heat pipe can transport heat from the core inside to outside about 18.20 kW, and total thermal resistance of hybrid heat pipe is 0.015 .deg. C/W. Due to unique features of long heat

  2. Enhancing ultra-high CPV passive cooling using least-material finned heat sinks

    Energy Technology Data Exchange (ETDEWEB)

    Micheli, Leonardo, E-mail: lm409@exeter.ac.uk; Mallick, Tapas K., E-mail: T.K.Mallick@exeter.ac.uk [Environment and Sustainability Institute, University of Exeter, Penryn, Cornwall TR10 9FE (United Kingdom); Fernandez, Eduardo F., E-mail: E.Fernandez-Fernandez2@exeter.ac.uk [Environment and Sustainability Institute, University of Exeter, Penryn, Cornwall TR10 9FE (United Kingdom); Centre of Advanced Studies in Energy and Environment, University of Jaen, Jaen 23071 (Spain); Almonacid, Florencia, E-mail: facruz@ujaen.es [Centre of Advanced Studies in Energy and Environment, University of Jaen, Jaen 23071 (Spain); Reddy, K. S., E-mail: ksreddy@iitm.ac.in [Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, 600036 (India)

    2015-09-28

    Ultra-high concentrating photovoltaic (CPV) systems aim to increase the cost-competiveness of CPV by increasing the concentrations over 2000 suns. In this work, the design of a heat sink for ultra-high concentrating photovoltaic (CPV) applications is presented. For the first time, the least-material approach, widely used in electronics to maximize the thermal dissipation while minimizing the weight of the heat sink, has been applied in CPV. This method has the potential to further decrease the cost of this technology and to keep the multijunction cell within the operative temperature range. The designing procedure is described in the paper and the results of a thermal simulation are shown to prove the reliability of the solution. A prediction of the costs is also reported: a cost of 0.151$/W{sub p} is expected for a passive least-material heat sink developed for 4000x applications.

  3. No-contact method of determining average working-surface temperature of plate-type radiation-absorbing thermal exchange panels of flat solar collectors for heating heat-transfer fluid

    International Nuclear Information System (INIS)

    Avezova, N.R.; Avezov, R.R.

    2015-01-01

    A brand new no-contact method of determining the average working-surface temperature of plate-type radiation-absorbing thermal exchange panels (RATEPs) of flat solar collectors (FSCs) for heating a heat-transfer fluid (HTF) is suggested on the basis of the results of thermal tests in full-scale quasistationary conditions. (authors)

  4. Environmental and economic performance of heating systems for energy-efficient dwellings: Case of passive and low-energy single-family houses

    International Nuclear Information System (INIS)

    Georges, L.; Massart, C.; Van Moeseke, G.; De Herde, A.

    2012-01-01

    In order to reduce the energy consumption of the building stock, a major trend is to drastically reduce the space-heating (SH) needs by improving the thermal performance of the envelope. In general, this measure is combined with efficient heating systems to minimize the delivered energy and greenhouse gas emissions. Nevertheless, these better systems are often more expensive so that the extra-investment could be hardly recovered for small-scale energy consumption. The main objective of the article is to show how equilibria between cost-effectiveness and environmental performance of heating systems are changed when small SH needs are considered (i.e. for passive and low-energy houses). The scope is limited to new single-family dwellings. Furthermore, the passive house standard provides means of simplifying the SH by using the ventilation air: the idea is that savings should counterbalance the extra-investment in super-insulation. In theory, a new global economic optimum is generated at the passive house level. The second objective of the work is to study which conditions could lead to this new optimum. Only a detached-house typology is investigated to address this last issue. Regarding methodology, all the investigations are done considering the Belgian context. Energy and environmental performance is evaluated using a method that complies with the EN-15603 and EN-15316 standards. - Highlights: ► Cost-benefit analysis is performed without incentives and is based on the Belgian market. ► Equilibria between cost-effectiveness and environmental performance of heating systems are changed for very low-energy houses. ► The space-heating simplification at the passive house level can hardly produce a new global economic optimum.

  5. Investigations on passive containment cooling

    International Nuclear Information System (INIS)

    Knebel, J.U.; Cheng, X.; Neitzel, H.J.; Erbacher, F.J.; Hofmann, F.

    1997-01-01

    The composite containment design for advanced LWRs that has been examined under the PASCO project is a promising design concept for purely passive decay heat removal after a severe accident. The passive cooling processes applied are natural convection and radiative heat transfer. Heat transfer through the latter process removes at an emission coefficient of 0.9 about 50% of the total heat removed via the steel containment, and thus is an essential factor. The heat transferring surfaces must have a high emission coefficient. The sump cooling concept examined under the SUCO project achieves a steady, natural convection-driven flow from the heat source to the heat sink. (orig./CB) [de

  6. Analysis and Modeling of Heat Generation in Overcharged Li-Ion Battery with Passive Cooling

    DEFF Research Database (Denmark)

    Coman, Paul Tiberiu; Veje, Christian

    2013-01-01

    This paper presents a dynamic model for simulating the heat generation in Lithium batteries and an investigation of the heat transfer as well as the capacity of Phase Change Materials (PCM’s) to store energy inside a battery cell module when the battery is overcharged. The study is performed...... by coupling a one-dimensional model of the electrochemical processes with a two-dimensional model for the heat transfer in a cross section of a battery pack. The heat generation and subsequent temperature rise is analyzed for different charging currents for the two cases where the cell is air......-cooled and passively cooled using a PCM, respectively. As expected, the results show that for high currents, the heat generation and implicitly the temperature increases. However, using a PCM the temperature increase is found to be limited allowing the battery to be overcharged to a certain degree. It is found...

  7. Cavity Control and Panel Control Strategies in Double-Panel Structures for Transmitted Noise Reduction

    NARCIS (Netherlands)

    Ho, J.; Kalverboer, J.; Berkhoff, Arthur P.

    2012-01-01

    Investigation and comparisons of the cavity control and the panel control in a double-panel structure are presented in this paper. The double-panel structure, which comprises two panels with air in the gap, provides the advantages of low sound-transmission at high frequency, low heat-transmission

  8. Comparative economic performance of selected passive solar heating and cooling technologies

    Science.gov (United States)

    Rutter, W.

    1981-05-01

    The economic performance of selected passive solar heating and cooling technologies which incorporate energy storage is assessed by using a set of uniform assumptions and methodologies. Where data are available, a given system is assessed at more than one geographical location. Results are obtained in the form of both payback period and net present value for residential applications, and in terms of net present value only for industrial/commercial uses. Results indicate that ventilated trombe walls, solar roof ponds, and certain night effect/floor storage strategies are cost effective, but night effect/rock bed cooling is not. Results also show that, although direct gain out-performs trombe walls in most parts of the country, both direct gain and trombe walls usually produce a net savings in the residential sector. Generally, however, tax regulations result in net economic loss for direct gain and trombe walls used to heat industrial and commercial buildings.

  9. Advanced simulations of energy demand and indoor climate of passive ventilation systems with heat recovery and night cooling

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    with little energy consumption and with satisfying indoor climate. The concept is based on using passive measures like stack and wind driven ventilation, effective night cooling and low pressure loss heat recovery using two fluid coupled water-to-air heat exchangers developed at the Technical University...... simulation program ESP-r to model the heat and air flows and the results show the feasibility of the proposed ventilation concept in terms of low energy consumption and good indoor climate....

  10. Effects of Solar Photovoltaic Panels on Roof Heat Transfer

    Science.gov (United States)

    Dominguez, A.; Klessl, J.; Samady, M.; Luvall, J. C.

    2010-01-01

    Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than

  11. Behavior of sandwich panels in a fire

    Science.gov (United States)

    Chelekova, Eugenia

    2018-03-01

    For the last decades there emerged a vast number of buildings and structures erected with the use of sandwich panels. The field of application for this construction material is manifold, especially in the construction of fire and explosion hazardous buildings. In advanced evacu-ation time calculation methods the coefficient of heat losses is defined with dire regard to fire load features, but without account to thermal and physical characteristics of building envelopes, or, to be exact, it is defined for brick and concrete walls with gross heat capacity. That is why the application of the heat loss coefficient expression obtained for buildings of sandwich panels is impossible because of different heat capacity of these panels from the heat capacities of brick and concrete building envelopes. The article conducts an analysis and calculation of the heal loss coefficient for buildings and structures of three layer sandwich panels as building envelopes.

  12. Heat Transfer Modes and their Coefficients for a Passive Containment Cooling System of PWR using a Multi-Pod Heat Pipe

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Gyeongho; Park, Junseok; Kim, Sangnyung [Kyung Hee Univ., Yongin (Korea, Republic of)

    2013-05-15

    If a reactor core is damaged due to a disaster such as happened at TEPCO's Fukushima nuclear power plant, the inevitable rise of super-heated steam that could potentially convert to hydrogen resulting from unimpeded temperature and pressure rises will threaten the integrity of the containment structure. To prevent this, safety and regulatory standards typically specify that the gas vent and external cooling systems be designed to maintain containment up to the level C limit for 24 hours and integrity for 48 hours after any damage to the core. Furthermore, it is recommended that the installation of the exhaust penetration unit have a minimum diameter of 3ft. However, installation of such cooling measures or penetration units is burdensome in terms of operational and maintenance costs not to mention the need to ensure a fleet of fire trucks to be on standby as well as the need to ensure a plentiful supply of water for cooling and a filtration system to clean the water. Therefore, the development of a reliable passive cooling system will be economically advantageous because the extra cost burdens of the external system can be omitted. The Passive Containment Cooling System (PCCS) using a multi-pod heat pipe proposed in this study satisfies these conditions.

  13. Passive heat removal from containment

    International Nuclear Information System (INIS)

    Gou, P.F.; Townsend, H.E.

    1990-01-01

    This patent describes a heat removal system for removing heat from a containment of a nuclear reactor. It comprises: a sealed suppression chamber in the containment; means for venting steam from the nuclear reactor into the suppression chamber upon occurrence of an event requiring dissipation of heat from the nuclear reactor. The suppression chamber containing a quantity of water; the suppression chamber having a gas-containing space above the water; a heat exchanger disposed within the gas-containing space of the suppression chamber; the heat exchanger including an enclosed structure for holding a heat-exchange fluid; means for metering a supply of heat-exchange fluid to the heat exchanger to maintain a predetermined level thereof in the enclosed structure. The heat-exchange fluid boiling in the heat exchanger in consequence of heat transfer thereto from steam present in the suppression chamber; means for separating a heat-exchange fluid vapor in the heat exchanger from the heat-exchange fluid; and means for discharging the vapor immediately following its separation from heat-exchange fluid directly from the heat exchanger to a location exterior of the containment, whereby heat is discharged from the suppression chamber, and the containment is maintained at a temperature and pressure below its design value

  14. Performance comparison between silicon solar panel and dye-sensitized solar panel in Malaysia

    Science.gov (United States)

    Hamed, N. K. A.; Ahmad, M. K.; Urus, N. S. T.; Mohamad, F.; Nafarizal, N.; Ahmad, N.; Soon, C. F.; Ameruddin, A. S.; Faridah, A. B.; Shimomura, M.; Murakami, K.

    2017-09-01

    In carrying out experimental research in performance between silicon solar panel and dye-sensitive solar panel, we have been developing a device and a system. This system has been developed consisting of controllers, hardware and software. This system is capable to get most of the input sources. If only need to change the main circuit and coding for a different source input value. This device is able to get the ambient temperature, surface temperature, surrounding humidity, voltage with load, current with load, voltage without load and current without load and save the data into external memory. This device is able to withstand the heat and rain as it was fabricated in a waterproof box. This experiment was conducted to examine the performance of both the solar panels which are capable to maintain their stability and performance. A conclusion based on data populated, the distribution of data for dye-sensitized solar panel is much better than silicon solar panel as dye-sensitized solar panel is very sensitive to heat and not depend only on midday where is that is the maximum ambient temperature for both solar panel as silicon solar panel only can give maximum and high output only when midday.

  15. Distinct Skeletal Muscle Gene Regulation from Active Contraction, Passive Vibration, and Whole Body Heat Stress in Humans.

    Science.gov (United States)

    Petrie, Michael A; Kimball, Amy L; McHenry, Colleen L; Suneja, Manish; Yen, Chu-Ling; Sharma, Arpit; Shields, Richard K

    2016-01-01

    Skeletal muscle exercise regulates several important metabolic genes in humans. We know little about the effects of environmental stress (heat) and mechanical stress (vibration) on skeletal muscle. Passive mechanical stress or systemic heat stress are often used in combination with many active exercise programs. We designed a method to deliver a vibration stress and systemic heat stress to compare the effects with active skeletal muscle contraction. The purpose of this study is to examine whether active mechanical stress (muscle contraction), passive mechanical stress (vibration), or systemic whole body heat stress regulates key gene signatures associated with muscle metabolism, hypertrophy/atrophy, and inflammation/repair. Eleven subjects, six able-bodied and five with chronic spinal cord injury (SCI) participated in the study. The six able-bodied subjects sat in a heat stress chamber for 30 minutes. Five subjects with SCI received a single dose of limb-segment vibration or a dose of repetitive electrically induced muscle contractions. Three hours after the completion of each stress, we performed a muscle biopsy (vastus lateralis or soleus) to analyze mRNA gene expression. We discovered repetitive active muscle contractions up regulated metabolic transcription factors NR4A3 (12.45 fold), PGC-1α (5.46 fold), and ABRA (5.98 fold); and repressed MSTN (0.56 fold). Heat stress repressed PGC-1α (0.74 fold change; p muscle contraction. Vibration induced FOXK2 (p muscle contractions. Understanding these responses may assist in developing regenerative rehabilitation interventions to improve muscle cell development, growth, and repair.

  16. Model-based analysis of nonstationary thermal mode in premises with an insolation passive heating system with a three-layer translucent shield

    International Nuclear Information System (INIS)

    Avezova, N.R.; Avezov, R.R.; Rashidov, Y.K. et al.

    2014-01-01

    The results of the model-based study of nonstationary thermal mode in premises with an insolation passive heating system with a three-layer translucent shield are presented. The article is aimed at determining daily variations in the air temperature of the heated premise on typical heating season days and analyzing the optimization of the thermal capacity of the short-term (daily) thermal battery of the heating system on this basis. (author)

  17. Experiments on the Heat Transfer and Natural Circulation Characteristics of the Passive Residual Heat Removal System for the Advanced Integral Type Reactor

    International Nuclear Information System (INIS)

    Park, Hyun-Sik; Choi, Ki-Yong; Cho, Seok; Park, Choon-Kyung; Lee, Sung-Jae; Song, Chul-Hwa; Chung, Moon-Ki; Lee, Un-Chul

    2004-01-01

    Experiments on the heat transfer characteristics and natural circulation performance of the passive residual heat removal system (PRHRS) for the SMART-P have been performed using the high temperature/high pressure thermal-hydraulic test facility (VISTA). The VISTA facility consists of the primary loop, the secondary loop, the PRHRS loop, and auxiliary systems to simulate the SMART-P, a pilot plant of the SMART. The primary loop is composed of the steam generator (SG) primary side, a simulated core, a main coolant pump, and loop piping, and the PRHRS loop consists of the SG secondary side, a PRHRS heat exchanger, and loop piping. The natural circulation performance of the PRHRS, the heat transfer characteristics of the PRHRS heat exchangers and the emergency cooldown tank (ECT), and the thermal-hydraulic behavior of the primary loop are intensively investigated. The experimental results show that the coolant flows steadily in the PRHRS loop and the heat transfers through the PRHRS heat exchanger and the emergency cooldown tank are sufficient enough to enable the natural circulation of the coolant. The results also show that the core decay heat can be sufficiently removed from the primary loop with the operation of the PRHRS. (authors)

  18. Combined Active and Passive Solar Space Heating and Solar Hot Water Systems for an Elementary School in Boise, Idaho.

    Science.gov (United States)

    Smull, Neil A.; Armstrong, Gerald L.

    1979-01-01

    Amity Elementary School in Boise, Idaho, features a solar space heating and domestic hot water system along with an earth covering to accommodate the passive aspects of energy conservation. (Author/MLF)

  19. Passive containment system

    International Nuclear Information System (INIS)

    Kleimola, F.W.

    1977-01-01

    Disclosed is a containment system that provides complete protection entirely by passive means for the loss of coolant accident in a nuclear power plant and wherein all stored energy released in the coolant blowdown is contained and absorbed while the nuclear fuel is prevented from over-heating by a high containment back-pressure and a reactor vessel refill system. The primary containment vessel is restored to a high sub-atmospheric pressure within a few minutes after accident initiation and the decay heat is safely transferred to the environment while radiolytic hydrogen is contained by passive means. 20 claims, 14 figures

  20. Regulatory Considerations for the Long Term Cooling Safe Shutdown Requirements of the Passive Residual Heat Removal Systems in Advanced Reactors

    International Nuclear Information System (INIS)

    Sim, S. K.; Bae, S. H.; Kim, Y. S.; Hwang, Min Jeong; Bang, Young Seok; Hwang, Taesuk

    2016-01-01

    USNRC approved safe shutdown at 215.6 .deg. C for a safe and long term cooling state for the redundant passive RHRSs by SECY-94-084. USNRC issued COLA(Combined Construction and Operating License) for the Levy County NP Unit-1/2 for the AP1000 passive RHRSs in 2014. Korea Hydro and Nuclear Power(KHNP) is developing APR+ and adopted Passive Auxiliary Feedwater System(PAFS) as a new passive RHRS design. Korea Institute of Nuclear Safety(KINS) has been developing regulatory guides for the advanced safety design features of the advanced ALWRs which has plan to construct in near future in Korea[5]. Safety and regulatory issues as well as the safe shut down requirements of the passive RHRS are discussed and considerations in developing regulatory guides for the passive RHRS are presented herein. Passive RHRSs have been introduced as new safety design features for the advanced reactors under development in Korea. These passive RHRSs have potential advantages over existing active RHRS, however, their functions are limited due to inherent ability of passive heat removal processes. It is high time to evaluate the performance of the passive PRHRs and develop regulatory guides for the safety as well as the performance analyses of the passive RHRS

  1. Open-loop heat-recovery dryer

    Science.gov (United States)

    TeGrotenhuis, Ward Evan

    2013-11-05

    A drying apparatus is disclosed that includes a drum and an open-loop airflow pathway originating at an ambient air inlet, passing through the drum, and terminating at an exhaust outlet. A passive heat exchanger is included for passively transferring heat from air flowing from the drum toward the exhaust outlet to air flowing from the ambient air inlet toward the drum. A heat pump is also included for actively transferring heat from air flowing from the passive heat exchanger toward the exhaust outlet to air flowing from the passive heat exchanger toward the drum. A heating element is also included for further heating air flowing from the heat pump toward the drum.

  2. PVT Panels. Fully renewable and competitive

    International Nuclear Information System (INIS)

    Bakker, M.; Strootman, K.J.; Jong, M.J.M.

    2003-10-01

    A photovoltaic/thermal (PVT) panel is a combination of photovoltaic cells with a solar thermal collector, generating solar electricity and solar heat simultaneously. PVT panels generate more solar energy per unit surface area than a combination of separate PV panels and solar thermal collectors, and share the aesthetic advantage of PV. After several years of research, PVT panels have been developed into a product that is now ready for market introduction. One of the most promising system concepts, consisting of 25 m 2 of PVT panels and a ground coupled heat pump, has been simulated in TRNSYS, and has been found to be able to fully cover both the building related electricity and heat consumption, while keeping the long-term average ground temperature constant. The cost and payback time of such a system have been determined; it has been found that the payback time of this system is approximately two-thirds of the payback time of an identical system but with 21 m 2 of PV panels and 4 m 2 of solar thermal collectors. Finally, by looking at the expected growth in the PV and solar thermal collector market, the market potential for for PVT panels has been found to be very large

  3. Method of forming oxide coatings. [for solar collector heating panels

    Science.gov (United States)

    Mcdonald, G. E. (Inventor)

    1983-01-01

    This invention is concerned with an improved plating process for covering a substrate with a black metal oxide film. The invention is particularly directed to making a heating panel for a solar collector. A compound is electrodeposited from an aqueous solution containing cobalt metal salts onto a metal substrate. This compound is converted during plating into a black, highly absorbing oxide coating which contains hydrated oxides. This is achieved by the inclusion of an oxidizing agent in the plating bath. The inclusion of an oxidizing agent in the plating bath is contrary to standard electroplating practice. The hydrated oxides are converted to oxides by treatment in a hot bath, such as boiling water. An oxidizing agent may be added to the hot liquid treating bath.

  4. ALPHA - The long-term passive decay heat removal and aerosol retention program

    International Nuclear Information System (INIS)

    Guentay, S.; Varadi, G.; Dreier, J.

    1996-01-01

    The Paul Scherrer Institute initiated the major new experimental and analytical program ALPHA in 1990. The program is aimed at understanding the long-term decay heat removal and aerosol questions for the next generation of Passive Light Water Reactors. The ALPHA project currently includes four major items: the large-scale, integral system behaviour test facility PANDA, which will be used to examine multidimensional effects of the SBWR decay heat removal system; an investigation of the thermal hydraulics of natural convection and mixing in pools and large volumes (LINX); a separate-effects study of aerosols transport and deposition in plenum and tubes (AIDA); while finally, data from the PANDA facility and supporting separate effects tests will be used to develop and qualify models and provide validation of relevant system codes. The paper briefly reviews the above four topics and current status of the experimental facilities. (author). 3 refs, 12 figs

  5. ALPHA - The long-term passive decay heat removal and aerosol retention program

    Energy Technology Data Exchange (ETDEWEB)

    Guentay, S; Varadi, G; Dreier, J [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1996-12-01

    The Paul Scherrer Institute initiated the major new experimental and analytical program ALPHA in 1990. The program is aimed at understanding the long-term decay heat removal and aerosol questions for the next generation of Passive Light Water Reactors. The ALPHA project currently includes four major items: the large-scale, integral system behaviour test facility PANDA, which will be used to examine multidimensional effects of the SBWR decay heat removal system; an investigation of the thermal hydraulics of natural convection and mixing in pools and large volumes (LINX); a separate-effects study of aerosols transport and deposition in plenum and tubes (AIDA); while finally, data from the PANDA facility and supporting separate effects tests will be used to develop and qualify models and provide validation of relevant system codes. The paper briefly reviews the above four topics and current status of the experimental facilities. (author). 3 refs, 12 figs.

  6. Reduction of carbon dioxide emissions by solar water heating systems and passive technologies in social housing

    International Nuclear Information System (INIS)

    Bessa, Vanessa M.T.; Prado, Racine T.A.

    2015-01-01

    Growing global concern regarding climate change motivates technological studies to minimize environmental impacts. In this context, solar water heating (SWH) systems are notably prominent in Brazil, primarily because of the abundance of solar energy in the country. However, SWH designs have not always been perfectly developed. In most projects, the installation option of the solar system only considers the electric power economy aspects and not the particular characteristics of each climatic zone. Thus, the primary objective of this paper is to assess the potential of carbon dioxide reduction with the use of SWH in comparison with electric showers in social housing in several Brazilian climatic zones. The Brazilian government authorities have created public policies to encourage the use of these technologies primarily among the low-income population. The results of this paper indicate that hot climactic regions demonstrate a low reduction of CO 2 emissions with SWH installations. Thus, solar radiation is not useful for water heating in those regions, but it does lead to a large fraction of household cooling loads, implying a demand for electrical energy for air conditioning or requiring the adoption of passive techniques to maintain indoor temperatures below threshold values. -- Graphical abstract: Display Omitted -- Highlights: •Brazil has created public policies to increase the use of solar water heating in social housing. •We have evaluated the potential for reduction of CO 2 emissions installing solar water heating. •We have found that the coldest regions have the greatest potential for reducing emissions. •Passive technologies for thermal comfort in hot climate households are more useful than solar water heating systems

  7. Prediction of Heat Removal Capacity of Horizontal Condensation Heat Exchanger submerged in Pool

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Seong-Su; Hong, Soon-Joon [FNC Tech., Yongin (Korea, Republic of); Cho, Hyoung-Kyu [Seoul National University, Seoul (Korea, Republic of); Park, Goon-Cherl [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2014-10-15

    As representative passive safety systems, there are the passive containment cooling system (PCCS) of ESBWR, the emergency condenser system (ECS) of the SWR-1000, the passive auxiliary feed-water system (PAFS) of the APR+ and etc. During the nuclear power plant accidents, these passive safety systems can cool the nuclear system effectively via the heat transfer through the steam condensation, and then mitigate the accidents. For the optimum design and the safety analysis of the passive safety system, it is essential to predict the heat removal capacity of the heat exchanger well. The heat removal capacity of the horizontal condensation heat exchanger submerged in a pool is determined by a combination of a horizontal in-tube condensation heat transfer and a boiling heat transfer on the horizontal tube. Since most correlations proposed in the previous nuclear engineering field were developed for the vertical tube, there is a certain limit to apply these correlations to the horizontal tube. Therefore, this study developed the heat transfer model for the horizontal Ushaped condensation heat exchanger submerged in a pool to predict well the horizontal in-tube condensation heat transfer, the boiling heat transfer on the horizontal tube and the overall heat removal capacity of the heat exchanger using the best-estimate system analysis code, MARS.

  8. The setup of a mobile mobility panel for the Netherlands

    NARCIS (Netherlands)

    Geurs, Karst Teunis; Veenstra, Sander; Thomas, Tom

    2013-01-01

    This paper describes the setup of the Dutch Mobile Mobility Panel project, in which GPS-enabled mobile phones (smartphones) are used as a passive multiple-week and multiple-year travel behaviour data collection tool. The data collection methodology used in the Dutch Mobile Mobility Panel comprised

  9. Hood River Passive House

    Energy Technology Data Exchange (ETDEWEB)

    Hales, David [BA-PIRC, Spokane, WA (United States)

    2014-01-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

  10. The Heat Exchanger for Passive Part ECCS of WWER-1000 on Base of the Thermo siphons

    International Nuclear Information System (INIS)

    Kirov, V.; Chulkin, O.

    2008-01-01

    One of NPP's systems providing safe operation is the system of emergency core cooling system (ECCS), which primary function in accidents is to flood the nuclear reactor core and to assure the sub critical condition and core cooling. At injection of cold water in reactor thermal stresses and thermal fatigue in the vessel cladding and constructional materials are arise. Low temperature of the water injected in reactor is a reason of occurrence of these undesirable consequences. Some variants of the water heating in accumulators of ECCS are considered. Now at Ukrainian NPPs the electrical heating in accumulators is used. Electrical heaters create the essential additional loading to diesel generators at imposing of two accidents - the large break and losses of power supplies on own needs. It is offered to use a heater in accumulators that working by a principle two-phase thermal siphon which advantages is: small dimensions, small delay and design reliability. In such heat exchanger the heating medium is a direct steam and the heated up medium is water with boric acid from accumulators of ECCS. Under requirements of the service regulations of ECCS accumulators it is necessary to guarantee injected water heating up to 90 ?? in case of a small break and to 150 ?? in case of the large break. Results of calculations for different external diameters of a tube of thermal siphon which have allowed to define the constructive sizes of heat exchanger, providing necessary conditions for required functioning of passive part ECCS are submitted The calculation and analysis of operating modes of the changed circuit of passive part ECCS for various accidents is carried out. The calculated pressure drop indicates that changes do not have essential influence on system work as a whole. Thus, the submitted decision provides the increase of reliability of ECCS at small and large breaks accidents, i.e. in all modes stipulated by the project.(author)

  11. Health risk associated with passive houses; an exploration

    NARCIS (Netherlands)

    Hasselaar, E.

    2009-01-01

    The passive house standard of northern European countries functions as an inspiration for home owners and project developers for building or retrofitting with high energy ambitions. Passive houses typically involve high insulation levels and heat recovery ventilation. Residual heating is based on

  12. TEPSS - Technology Enhancement for Passive Safety Systems

    International Nuclear Information System (INIS)

    Hart, J.; Slegers, W.J.M.; Boer, S.L. de; Huggenberger, M.; Lopez Jimenez, J.; Munoz-Cabo Gonzalez, J.L.; Reventos Puigjaner, F.

    2000-01-01

    The objective of the TEPSS project was to make significant additions to the technology base of the European Simplified Boiling Water Reactor (ESBWR). The project focused on mixing and stratification phenomena in large water pools, passive decay heat removal from containments, and effects of aerosol deposition inside a passive heat exchanger. The PSI experimental facility LINX (Large-scale Investigation of Natural Circulation and Mixing) has been used to investigate venting of steam and steam-noncondensable gas mixtures into water pools. The test revealed that no significant steam bypass could be detected when injecting a mixture of steam or air and that mixing was very efficient. In addition to the tests, 3-D numerical computations and initial model development have been performed to study the behaviour of bubble plumes in water pools. The major part of the TEPSS project studied selective aspects of the response technology of modem pressure-suppression type containment designs and of passive-type decay heat removal systems. The work included an experimental phase using the large-scale experimental facility PANDA (Passive Nachwaermeabfuhr und Druckabbau), operated by PSI, where eight experiments successfully have been executed to test the performance of the ESBWR containment configuration. The PANDA tests have been analysed successfully using thermalhydraulic system analysis codes and 3-D CFD codes. The AIDA (Aerosol Impaction and Deposition Analysis) experimental facility of PSI has been used to investigate the degradation of passive decay heat removal due to fission product aerosols deposited on the inside surfaces of the PCC (Passive Containment Cooler) heat exchanger tubes. The one test performed revealed that the degradation of the heat transfer in the PCC tubes due to the deposition of aerosols reached about 20%. The test has been analysed using the MELCOR severe accident analysis code. (author)

  13. Passive cooling in modern nuclear reactors

    International Nuclear Information System (INIS)

    Rouai, N. M.

    1998-01-01

    This paper presents some recent experimental results performed with the aim of understanding the mechanism of passive cooling. The AP 600 passive containment cooling system is simulated by an electrically heated vertical pipe, which is cooled by a naturally induced air flow and by a water film descending under gravity. The results demonstrate that although the presence of the water film improved the heat transfer significantly, the mode of heat transfer was very dependent on the experimental parameters. Preheating the water improved both film stability and overall cooling performance

  14. Distinct Skeletal Muscle Gene Regulation from Active Contraction, Passive Vibration, and Whole Body Heat Stress in Humans.

    Directory of Open Access Journals (Sweden)

    Michael A Petrie

    Full Text Available Skeletal muscle exercise regulates several important metabolic genes in humans. We know little about the effects of environmental stress (heat and mechanical stress (vibration on skeletal muscle. Passive mechanical stress or systemic heat stress are often used in combination with many active exercise programs. We designed a method to deliver a vibration stress and systemic heat stress to compare the effects with active skeletal muscle contraction.The purpose of this study is to examine whether active mechanical stress (muscle contraction, passive mechanical stress (vibration, or systemic whole body heat stress regulates key gene signatures associated with muscle metabolism, hypertrophy/atrophy, and inflammation/repair.Eleven subjects, six able-bodied and five with chronic spinal cord injury (SCI participated in the study. The six able-bodied subjects sat in a heat stress chamber for 30 minutes. Five subjects with SCI received a single dose of limb-segment vibration or a dose of repetitive electrically induced muscle contractions. Three hours after the completion of each stress, we performed a muscle biopsy (vastus lateralis or soleus to analyze mRNA gene expression.We discovered repetitive active muscle contractions up regulated metabolic transcription factors NR4A3 (12.45 fold, PGC-1α (5.46 fold, and ABRA (5.98 fold; and repressed MSTN (0.56 fold. Heat stress repressed PGC-1α (0.74 fold change; p < 0.05; while vibration induced FOXK2 (2.36 fold change; p < 0.05. Vibration similarly caused a down regulation of MSTN (0.74 fold change; p < 0.05, but to a lesser extent than active muscle contraction. Vibration induced FOXK2 (p < 0.05 while heat stress repressed PGC-1α (0.74 fold and ANKRD1 genes (0.51 fold; p < 0.05.These findings support a distinct gene regulation in response to heat stress, vibration, and muscle contractions. Understanding these responses may assist in developing regenerative rehabilitation interventions to improve muscle cell

  15. Energy efficiency policies for space heating in EU countries: A panel data analysis for the period 1990–2010

    International Nuclear Information System (INIS)

    Ó Broin, Eoin; Nässén, Jonas; Johnsson, Filip

    2015-01-01

    Highlights: • Space heating demand between 1990 and 2010 modelled using a panel of 14 EU countries. • The impacts of 260 efficiency polices affecting space heating demand are examined. • Regulatory policies found to have had a greater success than financial or informative. • High priority should be given to regulatory policies for space heating energy goals. - Abstract: We present an empirical analysis of the more than 250 space heating-focused energy efficiency policies that have been in force at the EU and national levels in the period 1990–2010. This analysis looks at the EU-14 residential sector (Pre-2004 EU-15, excluding Luxembourg) using a panel data regression analysis on unit consumption of energy for space heating (kWh/m 2 /year). The policies are represented as a regression variable using a semi-quantitative impact estimation obtained from the MURE Policy Database. The impacts of the policies as a whole, and subdivided into financial, regulatory, and informative policies, are examined. The correlation between the actual reductions in demand and the estimated impact of regulatory policies is found to be stronger than the corresponding correlations with the respective impacts of financial policies and informative polices. Together with the well-known market barriers to energy efficiency that exist in the residential sector, these findings suggest that regulatory policy measures be given a high priority in the design of an effective pathway towards the EU-wide goals for space heating energy

  16. Passive energy standard in building as a perspective of sustainable development - first passive houses in Croatia

    International Nuclear Information System (INIS)

    Miscevic, Lj.

    2005-01-01

    The paper presents the projects and implementation of the first passive family houses in Croatia. The Croatian Solar House (CSH) is a national technological-development project by a group of authors, which is based on passive house standard as an energy-terms point of departure. The House EV1 is a wood-made passive house under construction, while the House M4 is the first passive house in Croatia made in poro-concrete and reinforced concrete made ceiling slabs. Both houses comply with the heating energy consumption requirements under the passive house definition, i.e., the annual consumption does not exceed 15 kWh/m2. These houses are also referred to as 'houses without heating', 'houses with thermal comfort without heating' or 'one-liter houses' because their consumption is equivalent to one liter of fuel oil by one square meter a year. Assuming the high-value thermal protection, passive house is equipped with an installation system which houses a heat pump and ventilation system for continuous introduction of fresh air indoors. The use of renewable energy sources enabled the accomplishment by far the biggest energy savings in the construction industry, ensuring optimal conditions for healthy living without harmful gas emissions. Since 1990 there is an exponential growth of constructed passive houses in Europe. Germany is leading this trend with total of 150,000 free-standing houses, house raw units or residential units in small multi-apartment buildings. The research project-program of the European Union: Cost Efficiency Passive Houses as European Union Standard (CEPHEUS) has confirmed, by scientific monitoring during several years, the energy- and cost-efficiency of such architecture and construction model in more than 250 units in Germany, France, Austria and Switzerland. Therefore the passive house is proposed as a standard for residential architecture and construction, but also for general construction of all functional types of non-residential architecture

  17. Humidity measurements in passive heat and moisture exchangers applications: a critical issue.

    Science.gov (United States)

    Dubini, G; Fumero, R

    2000-01-01

    A reliable, quantitative assessment of humidification performances of passive heat and moisture exchangers in mechanically-ventilated patients is still to be achieved, although relevant efforts have been made to date. One of the major problems to tackle consists in the difficulty of humidity measurements, both in vivo (during either anaesthesia or intensive care unit treatments) and in vitro set-ups. In this paper a review of the basic operation principles of humidity sensors as well as an analysis of their usage within in vivo and in vitro tests are presented. Particular attention is devoted to the limitations arising from the specific measurement set-up, as they may affect the results notably.

  18. Passive decay heat removal by sump cooling after core meltdown

    International Nuclear Information System (INIS)

    Knebel, J.U.; Mueller, U.

    1996-01-01

    This article presents the basic physical phenomena and scaling criteria of decay heat removal from a large coolant pool by single-phase and two-phase natural circulation flow. The physical significance of the dimensionless similarity groups derived is evaluated. The above results are applied to the SUCO program that is performed at the Forschungszentrum Karlsruhe. The SUCO program is a three-step series of scaled model experiments investigating the possibility of a sump cooling concept for future light water reactors. The sump cooling concept is based on passive safety features within the containment. The work is supported by the German utilities and the Siemens AG. The article gives first measurement results of the 1:20 linearly scaled plane two-dimensional SUCOS-2D test facility. The experimental results of the model geometry are transformed to prototype conditions

  19. Thermal hydraulic studies for passive heat transport systems relevant to advanced reactors

    International Nuclear Information System (INIS)

    Vijayan, P.K.; Sharma, M.; Borgohain, A.; Srivastava, A.K.; Pilkhwal, D.S.; Maheshwari, N.K.

    2014-01-01

    Nuclear is the only non-green house gas generating power source that can replace fossil fuels and can be commercially deployed in large scale. However, the enormous developmental efforts and safety upgrades during the past six decades have somewhat eroded the economic competitiveness of water-cooled reactors which form the mainstay of the current nuclear power programme. Further, the introduction of the supercritical Rankine cycle and the gas turbine based advanced fuel cycles have enhanced the efficiency of fossil fired power plants (FPP) thereby reducing its greenhouse gas emissions. The ongoing development of ultra-supercritical and advanced ultra-supercritical turbines aims to further reduce the greenhouse gas emissions and economic competitiveness of FPPs. In the backdrop of these developments, the nuclear industry also initiated development of advanced nuclear power plants (NPP) with improved efficiency, sustainability and enhanced safety as the main goals. A review of the advanced reactor concepts being investigated currently reveals that excepting the SCWR, all other concepts use coolants other than water. The coolants used are lead, lead bismuth eutectic, liquid sodium, molten salts, helium and supercritical water. Besides, some of these are employing passive systems to transport heat from the core under normal operating conditions. In view of this, a study is in progress at BARC to examine the performance of simple passive systems using SC CO 2 , SCW, LBE and molten salts as the coolant. This paper deals with some of the recent results of these studies. The study focuses on the steady state, transient and stability behaviour of the passive systems with these coolants. (author)

  20. Evaluation on driving force of natural circulation in downcomer for passive residual heat removal system in JAERI passive safety reactor JPSR

    International Nuclear Information System (INIS)

    Kunii, Katsuhiko; Iwamura, Takamichi; Murao, Yoshio

    1997-01-01

    The driving-force of the natural circulation in the residual heat removal (RHR) system for the JPSR (JAERI Passive Safety Reactor) is given as a gravity force of the density difference between hotter coolant in core and upper plenum and cooler coolant in downcomer. The amount of density difference and time to achieve the enough density difference for the RHR system change directly dependent on the thermal fluid flow pattern in downcomer of annulus flow pass. The purposes of the present study are to investigate the possibilities of the followings by evaluating the three-dimensional thermal fluid flow in downcomer by numerical analysis using the STREAM code; 1) promotion of making the flow pattern uniform in downcomer by installing a baffle, 2) achievement of an enough driving-force of the natural circulation, 3) validity of one-point assumption, that is, complete mixing down-flow assumption for the three-dimensional thermal fluid flow in downcomer to evaluate the function of the passive RHR system. The following conclusions were obtained: (1) The effect of baffle on the thermal fluid flow and driving-force is little, (2) The driving-force required for natural circulation cooling can be obtained in wide range of inlet velocity even if the flow is multi-dimensional, (3) Both in initial transient stage and in steady-state, the one-point assumption can be applied to evaluate the driving-force of natural circulation in the passive RHR system. (author)

  1. NPR and ANSI Containment Study Using Passive Cooling Techniques

    International Nuclear Information System (INIS)

    Shin, J. J.; Iotti, R. C.; Wright, R. F.

    1993-01-01

    Passive containment cooling study of NPR (New Production Reactor) and ANSI (Advanced Neutron Source) following postulated loss of coolant accident with a coincident station blackout due to total loss of all alternating current power are studied analytically and experimentally. All the reactor and containment cooling under this condition would rely on the passive cooling system which removes reactor decay heat and provides emergency core and containment cooling. Containment passive emergency core and containment cooling. Containment passive cooling for this study takes place in the annulus between containment steel shell and concrete shield building by natural convection air flow and concrete shield building by natural convection air flow and thermal radiation. Various heat transfer coefficients inside annular air space were investigated by running the modified Contempt code Contempt-Npr. In order to verify proper heat transfer coefficient, temperature, heat flux and velocity profiles were measured inside annular air space of the test facility which is a 24 foot (7.3m) high, steam heated inner cylinder of three foot (.91m) diameter and five and halt foot (1.7m) diameter outer cylinder. Comparison of Contempt-Npr and WGOTHIC was done for reduced scale Npr. It is concluded that Npr and ANSI containments can be passively cooled with air alone without extended cooling surfaces or passive water spray

  2. Control of Sound Transmission with Active-Passive Tiles

    OpenAIRE

    Goldstein, Andre L.

    2006-01-01

    Nowadays, numerous applications of active sound transmission control require lightweight partitions with high transmission loss over a broad frequency range and simple control strategies. In this work an active-passive sound transmission control approach is investigated that potentially addresses these requirements. The approach involves the use of lightweight stiff panels, or tiles, attached to a radiating base structure through active-passive soft mounts and covering the structure surface. ...

  3. Passive House Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Strom, I.; Joosten, L.; Boonstra, C. [DHV Sustainability Consultants, Eindhoiven (Netherlands)

    2006-05-15

    PEP stands for 'Promotion of European Passive Houses' and is a consortium of European partners, supported by the European Commission, Directorate General for Energy and Transport. In this working paper an overview is given of Passive House solutions. An inventory has been made of Passive House solutions for new build residences applied in each country. Based on this, the most common basic solutions have been identified and described in further detail, including the extent to which solutions are applied in common and best practice and expected barriers for the implementation in each country. An inventory per country is included in the appendix. The analysis of Passive House solutions in partner countries shows high priority with regard to the performance of the thermal envelope, such as high insulation of walls, roofs, floors and windows/ doors, thermal bridge-free construction and air tightness. Due to the required air tightness, special attention must be paid to indoor air quality through proper ventilation. Finally, efficient ((semi-)solar) heating systems for combined space and DHW heating still require a significant amount of attention in most partner countries. Other basic Passive House solutions show a smaller discrepancy with common practice and fewer barriers have been encountered in partner countries. In the next section, the general barriers in partner countries have been inventoried. For each type of barrier a suggested approach has been given. Most frequently encountered barriers in partner countries are: limited know-how; limited contractor skills; and acceptation of Passive Houses in the market. Based on the suggested approaches to overcoming barriers, this means that a great deal of attention must be paid to providing practical information and solutions to building professionals, providing practical training to installers and contractors and communication about the Passive House concept to the market.

  4. Design and construction of radiant panel for cooling and heating with photovoltaic and thermoelectric element modules; Taiyo denchi to netsuden soshi module wo mochiita fukusha reidanbo panel no sekkei oyobi shisaku

    Energy Technology Data Exchange (ETDEWEB)

    Sato, M; Tani, T [Science University of Tokyo, Tokyo (Japan); Kadotani, K; Imaizumi, H [Komatsu Ltd., Tokyo (Japan)

    1997-11-25

    Utilizing cooling properties and current voltage characteristics of a small cooling panel using thermoelectric elements which had been fabricated previously on a trial basis, design and prototype production were executed on a large radiant cooling and heating panel driven by photovoltaic cell modules. The panel design set the cooling area to about 0.5 m {sup 2} and the number of elements to 70 pieces, and optimum number of elements in series and parallel connection was derived. As a result of the analysis, it was made clear that the optimum number of thermoelectric module arrays in series and parallel connection varies depending on insolation intensity. It was found preferable that the number of parallel connection array be set to one to two in a region or time period in which low insolation intensity is distributed in greater amount. In the case where high insolation intensity is distributed in a greater amount, setting it to two to three is preferable. By using the structured design method and the HASP Tokyo data, thermoelectric element modules were interconnected with 35 modules in series and two in parallel on a cooling panel installed on the roof of the Science University of Tokyo. A simulation result revealed that the average temperature difference on the cooled surface in summer is 4.37 degC, and the solar cell utilization rate is 0.67. It is necessary in the future to improve heat dissipation efficiency and area ratio. 1 ref., 12 figs., 5 tabs.

  5. Passive cooling containment study

    International Nuclear Information System (INIS)

    Shin, J.J.; Iotti, R.C.; Wright, R.F.

    1993-01-01

    Pressure and temperature transients of nuclear reactor containment following postulated loss of coolant accident with a coincident station blackout due to total loss of all alternating current power are studied analytically and experimentally for the full scale NPR (New Production Reactor). All the reactor and containment cooling under this condition would rely on the passive cooling system which removes reactor decay heat and provides emergency core and containment cooling. Containment passive cooling for this study takes place in the annulus between containment steel shell and concrete shield building by natural convection air flow and thermal radiation. Various heat transfer coefficients inside annular air space were investigated by running the modified CONTEMPT code CONTEMPT-NPR. In order to verify proper heat transfer coefficient, temperature, heat flux, and velocity profiles were measured inside annular air space of the test facility which is a 24 foot (7.3m) high, steam heated inner cylinder of three foot (.91m) diameter and five and half foot (1.7m) diameter outer cylinder. Comparison of CONTEMPT-NPR and WGOTHIC was done for reduced scale NPR

  6. Two or three decades of passive directions

    International Nuclear Information System (INIS)

    Cook, J.

    1995-01-01

    This paper presents an overview of the direction of passive solar architecture. The topics of the paper include design temperatures for buildings, active vs passive, fuel vs philosophy, engineering vs architecture, the thermal scale: heating vs cooling, fuel subsidies, divergent practices, sustainability, lighting, health, the place of passive technology

  7. Modeling the thermal absorption factor of photovoltaic/thermal combi-panels

    NARCIS (Netherlands)

    Santbergen, R.; Zolingen, van R.J.C.

    2006-01-01

    In a photovoltaic/thermal combi-panel solar cells generate electricity while residual heat is extracted to be used for tap water heating or room heating. In such a panel the entire solar spectrum can be used in principle. Unfortunately long wavelength solar irradiance is poorly absorbed by the

  8. Passive houses: houses without heatings. Experience with the first demonstration building at Darmstadt, and prospects for low-cost passive houses; Passivhaeuser: Gebaeude ohne Heizung. Erfahrungen mit dem ersten Demonstrationsgebaeude in Darmstadt und Perspektiven fuer kostenguenstige Passivhaeuser

    Energy Technology Data Exchange (ETDEWEB)

    Feist, W. [Inst. Wohnen und Umwelt, Darmstadt (Germany)

    1998-12-31

    `Passive` houses, i.e. houses without active heating, are extremely energy-optimized houses: thanks to their efficient thermal protection, their heat demand falls below the threshold requiring a separate space heat distribution system (15 kWh/(m{sup 2}a)). Passive houses will account for an increasing proportion of new buildings already during the next years. Houses with zero thermal energy demand involve notably higher construction effort but do not contribute essentially more to the mitigation of environmental pollution. (orig.) [Deutsch] Das Passivhaus ist ein extremes Niedrigenergiehaus, bei welchem durch guten Waermeschutz gerade die Schwelle unterschritten wird, bei der kein separates Heizwaermeverteilsystem mehr benoetigt wird (15 kWh/(m{sup 2}a)). Passivhaeuser werden schon in den naechsten Jahren einen zunehmenden Anteil an den Neubauten haben. Nullheizenergiehaeuser fuehren gegenueber dem Passivhaus zu spuerbar hoeherem baulichen Aufwand, ohne die Umwelt bedeutend mehr zu entlasten. (orig.)

  9. Planning of solar heated plant for low-energy houses and passive houses. An introduction; Planlegging av solvarmeanlegg for lavenergiboliger og passivhus. En introduksjon

    Energy Technology Data Exchange (ETDEWEB)

    Andresen, Inger

    2008-07-01

    This guide gives an introduction to the most important principles in planning and projecting of solar heated plant in low-energy houses and passive houses. It is written mainly for architects and consultants involved in housing projects with ambitions to achieve low-energy or passive house standard, but will also be of value for builders and others interested in the topic. (AG). 35 refs., 27 figs

  10. On the Modern History of Passive Solar Architecture

    DEFF Research Database (Denmark)

    Marsh, Rob

    2017-01-01

    This article examines the paradox of passive solar architecture within the Nordic context of Denmark, Norway and Sweden. Regulative developments to reduce space heating demand since the 1970s oil crisis are explored, highlighting architectural responses and the rise in prom-inence of passive solar...... design. An empirical study of passive solar housing schemes docu-ments architectural strategy, energy savings and extensive problems with overheating. A theo-retical study examines how passive solar was seen as advantageous when viewed with the 1985-2005 space heating paradigm, but actually resulted...... of Nordic modernism meant that passive solar architecture became the de-facto visual, aesthetic and functional expression of environmental design at that time. The article concludes by explor-ing the implications of the environmental paradigm for the architectural profession. By positing the architectural...

  11. Wind power integration using individual heat pumps – Analysis of different heat storage options

    DEFF Research Database (Denmark)

    Hedegaard, Karsten; Mathiesen, Brian Vad; Lund, Henrik

    2012-01-01

    Significant installations of individual heat pumps are expected in future energy systems due to their economic competitiveness. This case study of the Danish energy system in 2020 with 50% wind power shows that individual heat pumps and heat storages can contribute to the integration of wind power....... Heat accumulation tanks and passive heat storage in the construction are investigated as two alternative storage options in terms of their ability to increase wind power utilisation and to provide cost-effective fuel savings. Results show that passive heat storage can enable equivalent to larger...... reductions in excess electricity production and fuel consumption than heat accumulation tanks. Moreover, passive heat storage is found to be significantly more cost-effective than heat accumulation tanks. In terms of reducing fuel consumption of the energy system, the installation of heat pumps is the most...

  12. Hybrid Active/Passive Control of Sound Radiation from Panels with Constrained Layer Damping and Model Predictive Feedback Control

    Science.gov (United States)

    Cabell, Randolph H.; Gibbs, Gary P.

    2000-01-01

    make the controller adaptive. For example, a mathematical model of the plant could be periodically updated as the plant changes, and the feedback gains recomputed from the updated model. To be practical, this approach requires a simple plant model that can be updated quickly with reasonable computational requirements. A recent paper by the authors discussed one way to simplify a feedback controller, by reducing the number of actuators and sensors needed for good performance. The work was done on a tensioned aircraft-style panel excited on one side by TBL flow in a low speed wind tunnel. Actuation was provided by a piezoelectric (PZT) actuator mounted on the center of the panel. For sensing, the responses of four accelerometers, positioned to approximate the response of the first radiation mode of the panel, were summed and fed back through the controller. This single input-single output topology was found to have nearly the same noise reduction performance as a controller with fifteen accelerometers and three PZT patches. This paper extends the previous results by looking at how constrained layer damping (CLD) on a panel can be used to enhance the performance of the feedback controller thus providing a more robust and efficient hybrid active/passive system. The eventual goal is to use the CLD to reduce sound radiation at high frequencies, then implement a very simple, reduced order, low sample rate adaptive controller to attenuate sound radiation at low frequencies. Additionally this added damping smoothes phase transitions over the bandwidth which promotes robustness to natural frequency shifts. Experiments were conducted in a transmission loss facility on a clamped-clamped aluminum panel driven on one side by a loudspeaker. A generalized predictive control (GPC) algorithm, which is suited to online adaptation of its parameters, was used in single input-single output and multiple input-single output configurations. Because this was a preliminary look at the potential

  13. Deep underground reactor (passive heat removal of LWR with hard neutron energy spectrum)

    Energy Technology Data Exchange (ETDEWEB)

    Hiroshi, Takahashi [Brookhaven National Lab., Upton, NY (United States)

    2001-07-01

    To run a high conversion reactor with Pu-Th fueled tight fueled assembly which has a long burn-up of a fuel, the reactor should be sited deep underground. By putting the reactor deep underground heat can be removed passively not only during a steady-state run and also in an emergency case of loss of coolant and loss of on-site power; hence the safety of the reactor can be much improved. Also, the evacuation area around the reactor can be minimized, and the reactor placed near the consumer area. This approach reduces the cost of generating electricity by eliminating the container building and shortening transmission lines. (author)

  14. Deep underground reactor (passive heat removal of LWR with hard neutron energy spectrum)

    International Nuclear Information System (INIS)

    Hiroshi, Takahashi

    2001-01-01

    To run a high conversion reactor with Pu-Th fueled tight fueled assembly which has a long burn-up of a fuel, the reactor should be sited deep underground. By putting the reactor deep underground heat can be removed passively not only during a steady-state run and also in an emergency case of loss of coolant and loss of on-site power; hence the safety of the reactor can be much improved. Also, the evacuation area around the reactor can be minimized, and the reactor placed near the consumer area. This approach reduces the cost of generating electricity by eliminating the container building and shortening transmission lines. (author)

  15. Panels of microporous insulation

    Energy Technology Data Exchange (ETDEWEB)

    McWilliams, J.A.; Morgan, D.E.; Jackson, J.D.J.

    1990-08-07

    Microporous thermal insulation materials have a lattice structure in which the average interstitial dimension is less than the mean free path of the molecules of air or other gas in which the material is arranged. This results in a heat flow which is less than that attributable to the molecular heat diffusion of the gas. According to this invention, a method is provided for manufacturing panels of microporous thermal insulation, in particular such panels in which the insulation material is bonded to a substrate. The method comprises the steps of applying a film of polyvinyl acetate emulsion to a non-porous substrate, and compacting powdery microporous thermal insulation material against the film so as to cause the consolidated insulation material to bond to the substrate and form a panel. The polyvinyl acetate may be applied by brushing or spraying, and is preferably allowed to dry prior to compacting the insulation material. 1 fig.

  16. Effects of duration of stay in temperate area on thermoregulatory responses to passive heat exposure in tropical south-east Asian males residing in Japan

    Directory of Open Access Journals (Sweden)

    Wijayanto Titis

    2012-09-01

    Full Text Available Abstract Background In this study, we investigated the effects of duration of stay in a temperate area on the thermoregulatory responses to passive heat exposure of residents from tropical areas, particularly to clarify whether they would lose their heat tolerance during passive heat exposure through residence in a temperate country, Japan. Methods We enrolled 12 males (mean ± SE age 25.7 ± 1.3 years from south-east Asian countries who had resided in Japan for a mean of 24.5 ± 5.04 months, and 12 Japanese males (age 24.1 ± 0.9 years. Passive heat exposure was induced through leg immersion in hot water (42°C for 60 minutes under conditions of 28°C air temperature and 50% relative humidity. Results Compared with the Japanese group, the tropical group displayed a higher pre-exposure rectal temperature (P P = 0.03. Additionally, the tropical group showed a tendency towards a lower total sweat rate (P = 0.06 and lower local sweat rate on the forehead (P = 0.07. The tropical group also had a significantly longer sweating onset time on the upper back (P = 0.04 compared with the Japanese groups. The tropical group who stayed in Japan for > 23 months sweated earlier on the forehead and upper back than those who stayed in Japan P P = 0.03 for the forehead and upper back, respectively. There was a positive correlation between duration of stay in Japan and total sweat rate (r = 0.58, P r = −0.73, P = 0.01 and on the upper back (r = −0.66, P = 0.02. Other physiological indices measured in this study did not show any difference between the subjects in the tropical group who had lived in Japan for a shorter time and those who had lived there for a longer time. Conclusions We conclude that the nature of heat acclimatization of the sweating responses to passive heat exposure that are acquired from long-term heat acclimatization is decayed by a stay in a temperate area, as shown

  17. Orbiter radiator panel solar focusing test

    Science.gov (United States)

    Howell, H. R.; Rankin, J. G.

    1983-01-01

    Test data are presented which define the area around the Orbiter radiator panels for which the solar reflections are concentrated to one-sun or more. The concave shape of the panels and their specular silver/Teflon coating causes focusing of the reflected solar energy which could have adverse heating effects on equipment or astronaut extravehicular activity (EVA) in the vicinity of the radiator panels. A room ambient test method was utilized with a one-tenth scale model of the radiator panels.

  18. Heart rate variability during exertional heat stress: effects of heat production and treatment.

    Science.gov (United States)

    Flouris, Andreas D; Bravi, Andrea; Wright-Beatty, Heather E; Green, Geoffrey; Seely, Andrew J; Kenny, Glen P

    2014-04-01

    We assessed the efficacy of different treatments (i.e., treatment with ice water immersion vs. natural recovery) and the effect of exercise intensities (i.e., low vs. high) for restoring heart rate variability (HRV) indices during recovery from exertional heat stress (EHS). Nine healthy adults (26 ± 3 years, 174.2 ± 3.8 cm, 74.6 ± 4.3 kg, 17.9 ± 2.8 % body fat, 57 ± 2 mL·kg·(-1) min(-1) peak oxygen uptake) completed four EHS sessions incorporating either walking (4.0-4.5 km·h(-1), 2 % incline) or jogging (~7.0 km·h(-1), 2 % incline) on a treadmill in a hot-dry environment (40 °C, 20-30 % relative humidity) while wearing a non-permeable rain poncho for a slow or fast rate of rectal temperature (T re) increase, respectively. Upon reaching a T re of 39.5 °C, participants recovered until T re returned to 38 °C either passively or with whole-body immersion in 2 °C water. A comprehensive panel of 93 HRV measures were computed from the time, frequency, time-frequency, scale-invariant, entropy and non-linear domains. Exertional heat stress significantly affected 60/93 HRV measures analysed. Analyses during recovery demonstrated that there were no significant differences between HRV measures that had been influenced by EHS at the end of passive recovery vs. whole-body cooling treatment (p > 0.05). Nevertheless, the cooling treatment required statistically significantly less time to reduce T re (p whole-body immersion in 2 °C water results in faster cooling, there were no observed differences in restoration of autonomic heart rate modulation as measured by HRV indices with whole-body cold-water immersion compared to passive recovery in thermoneutral conditions.

  19. Passive depressurization accident management strategy for boiling water reactors

    International Nuclear Information System (INIS)

    Liu, Maolong; Erkan, Nejdet; Ishiwatari, Yuki; Okamoto, Koji

    2015-01-01

    Highlights: • We proposed two passive depressurization systems for BWR severe accident management. • Sensitivity analysis of the passive depressurization systems with different leakage area. • Passive depressurization strategies can prevent direct containment heating. - Abstract: According to the current severe accident management guidance, operators are required to depressurize the reactor coolant system to prevent or mitigate the effects of direct containment heating using the safety/relief valves. During the course of a severe accident, the pressure boundary might fail prematurely, resulting in a rapid depressurization of the reactor cooling system before the startup of SRV operation. In this study, we demonstrated that a passive depressurization system could be used as a severe accident management tool under the severe accident conditions to depressurize the reactor coolant system and to prevent an additional devastating sequence of events and direct containment heating. The sensitivity analysis performed with SAMPSON code also demonstrated that the passive depressurization system with an optimized leakage area and failure condition is more efficient in managing a severe accident

  20. Passive depressurization accident management strategy for boiling water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Maolong, E-mail: liuml@vis.t.u-tokyo.ac.jp [Department of Nuclear Engineering and Management, School of Engineering, The University of Tokyo (Japan); Erkan, Nejdet [Nuclear Professional School, School of Engineering, The University of Tokyo (Japan); Ishiwatari, Yuki [Department of Nuclear Engineering and Management, School of Engineering, The University of Tokyo (Japan); Hitachi-GE Nuclear Energy, Ltd. (Japan); Okamoto, Koji [Nuclear Professional School, School of Engineering, The University of Tokyo (Japan)

    2015-04-01

    Highlights: • We proposed two passive depressurization systems for BWR severe accident management. • Sensitivity analysis of the passive depressurization systems with different leakage area. • Passive depressurization strategies can prevent direct containment heating. - Abstract: According to the current severe accident management guidance, operators are required to depressurize the reactor coolant system to prevent or mitigate the effects of direct containment heating using the safety/relief valves. During the course of a severe accident, the pressure boundary might fail prematurely, resulting in a rapid depressurization of the reactor cooling system before the startup of SRV operation. In this study, we demonstrated that a passive depressurization system could be used as a severe accident management tool under the severe accident conditions to depressurize the reactor coolant system and to prevent an additional devastating sequence of events and direct containment heating. The sensitivity analysis performed with SAMPSON code also demonstrated that the passive depressurization system with an optimized leakage area and failure condition is more efficient in managing a severe accident.

  1. Elevated-Temperature Tests Under Static and Aerodynamic Conditions on Honeycomb-Core Sandwich Panels

    Science.gov (United States)

    Groen, Joseph M.; Johnson, Aldie E., Jr.

    1959-01-01

    Stainless-steel honeycomb-core sandwich panels which differed primarily in skin thicknesses were tested at elevated temperatures under static and aerodynamic conditions. The results of these tests were evaluated to determine the insulating effectiveness and structural integrity of the panels. The static radiant-heating tests were performed in front of a quartz-tube radiant heater at panel skin temperatures up to 1,5000 F. The aerodynamic tests were made in a Mach 1.4 heated blowdown wind tunnel. The tunnel temperature was augmented by additional heat supplied by a radiant heater which raised the panel surface temperature above 8000 F during air flow. Static radiant-heating tests of 2 minutes duration showed that all the panels protected the load-carrying structure about equally well. Thin-skin panels showed an advantage for this short-time test over thick-skin panels from a standpoint of weight against insulation. Permanent inelastic strains in the form of local buckles over each cell of the honeycomb core caused an increase in surface roughness. During the aero- dynamic tests all of the panels survived with little or no damage, and panel flutter did not occur.

  2. Dependence of the coefficient of environmental thermal losses of radiation-absorbing thermal exchange panels of flat solar collectors for heating heat-transfer fluid from their average operating and ambient temperatures

    International Nuclear Information System (INIS)

    Avezova, N.R.; Avezov, R.R.

    2015-01-01

    The approximation formula is derived for calculating the normalized coefficient of thermal losses of flat solar collectors (FSCs) for heating heat-transfer fluid (HTF). These are used in hot water supply systems in the warmer part of the year, depending on the average working surface temperature of their radiation-absorbing thermal exchange panels (RATEPs) (t"-_w_s_r) and the ambient temperature (t_a_m_b) in their realistic variation range. (author)

  3. Investigation on Solar Heating System with Building-Integrated Heat Storage

    DEFF Research Database (Denmark)

    Heller, Alfred

    1996-01-01

    Traditional solar heating systems cover between 5 and 10% of the heat demand fordomestic hot water and comfort heating. By applying storage capacity this share can beincreased much. The Danish producer of solar heating systems, Aidt-Miljø, markets such a system including storage of dry sand heated...... by PP-pipe heat exchanger. Heat demand is reduced due to direct solar heating and due to storage. The storage affects the heat demand passively due to higher temperatures. Hence heat loss is reduced and passive heating is optioned. In theory, by running the system flow backwards, active heating can...... solar collector area of the system, was achieved. Active heating from the sand storage was not observed. The pay-back time for the system can be estimated to be similar to solar heated domestic hot water systems in general. A number of minor improvements on the system could be pointed out....

  4. Design of integrated passive safety system (IPSS) for ultimate passive safety of nuclear power plants

    International Nuclear Information System (INIS)

    Chang, Soon Heung; Kim, Sang Ho; Choi, Jae Young

    2013-01-01

    Highlights: • We newly propose the design concept of integrated passive safety system (IPSS). • It has five safety functions for decay heat removal and severe accident mitigation. • Simulations for IPSS show that core melt does not occur in accidents with SBO. • IPSS can achieve the passive in-vessel retention and ex-vessel cooling strategy. • The applicability of IPSS is high due to the installation outside the containment. -- Abstract: The design concept of integrated passive safety system (IPSS) which can perform various passive safety functions is proposed in this paper. It has the various functions of passive decay heat removal system, passive safety injection system, passive containment cooling system, passive in-vessel retention and cavity flooding system, and filtered venting system with containment pressure control. The objectives of this paper are to propose the conceptual design of an IPSS and to estimate the design characters of the IPSS with accident simulations using MARS code. Some functions of the IPSS are newly proposed and the other functions are reviewed with the integration of the functions. Consequently, all of the functions are modified and integrated for simplicity of the design in preparation for beyond design based accidents (BDBAs) focused on a station black out (SBO). The simulation results with the IPSS show that the decay heat can be sufficiently removed in accidents that occur with a SBO. Also, the molten core can be retained in a vessel via the passive in-vessel retention strategy of the IPSS. The actual application potential of the IPSS is high, as numerous strong design characters are evaluated. The installation of the IPSS into the original design of a nuclear power plant requires minimal design change using the current penetrations of the containment. The functions are integrated in one or two large tanks outside the containment. Furthermore, the operation time of the IPSS can be increased by refilling coolant from the

  5. Westinghouse Small Modular Reactor passive safety system response to postulated events

    International Nuclear Information System (INIS)

    Smith, M. C.; Wright, R. F.

    2012-01-01

    The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor. This paper is part of a series of four describing the design and safety features of the Westinghouse SMR. This paper focuses in particular upon the passive safety features and the safety system response of the Westinghouse SMR. The Westinghouse SMR design incorporates many features to minimize the effects of, and in some cases eliminates the possibility of postulated accidents. The small size of the reactor and the low power density limits the potential consequences of an accident relative to a large plant. The integral design eliminates large loop piping, which significantly reduces the flow area of postulated loss of coolant accidents (LOCAs). The Westinghouse SMR containment is a high-pressure, compact design that normally operates at a partial vacuum. This facilitates heat removal from the containment during LOCA events. The containment is submerged in water which also aides the heat removal and provides an additional radionuclide filter. The Westinghouse SMR safety system design is passive, is based largely on the passive safety systems used in the AP1000 R reactor, and provides mitigation of all design basis accidents without the need for AC electrical power for a period of seven days. Frequent faults, such as reactivity insertion events and loss of power events, are protected by first shutting down the nuclear reaction by inserting control rods, then providing cold, borated water through a passive, buoyancy-driven flow. Decay heat removal is provided using a layered approach that includes the passive removal of heat by the steam drum and independent passive heat removal system that transfers heat from the primary system to the environment. Less frequent faults such as loss of coolant accidents are mitigated by passive injection of a large quantity of water that is readily available inside containment. An automatic depressurization system is used to

  6. Passive Residential Houses with the Accumulation Properties of Ground as a Heat Storage Medium

    Science.gov (United States)

    Ochab, Piotr; Kokoszka, Wanda; Kogut, Janusz; Skrzypczak, Izabela; Szyszka, Jerzy; Starakiewicz, Aleksander

    2017-12-01

    Solar radiation is the primary source of life energy on Earth. The irradiance of the upper atmosphere is about 1360 W/m2, and it is estimated that about 1000 W/m2 reaches the ground. Long-term storage of heat energy is related to the use of a suitable thermal energy carrier. It may be either artificial or natural water tank, or artificial gravel-water tank, or aquifer or soil. It is justified to store the generated energy in large heating systems due to the nature of solar thermal energy. Typically, in such a solution storage space is a large solar collector farm. The reason for this is the proportionally small unit profits, which only in the case of large number of units provides sufficient energy that can be accumulated. It should be noted that Poland, a country located in a temperate and less harsh climate such as Scandinavia and Canada, has a relatively high potential for solar revenue. In the last decade, it has caused mainly small and individual heating installations. However, much of the municipal and industrial economy continues to rely on energy from non-renewable resources. This is due not only to the lack of a high-efficiency alternative to non-renewable energy resources, but also to the thermal state of buildings throughout the country, where old buildings require thermomodernization. This has the effect of both polluting the environment and the occurrence of smog, as well as pollutants in water and soil. This directly affects the occurrence of civilization diseases and other societal health problems. Therefore, the surplus of thermal clean energy that occurs during the spring and summer period should not only be used on a regular basis, but also stored for later winter use. The paper presents the concept of housing estate, which consists of 32 twin housing units. The solid character of buildings consistently refers to passive construction, and the materials meet the requirements for the passive buildings.

  7. A concept of JAERI passive safety light water reactor system (JPSR)

    Energy Technology Data Exchange (ETDEWEB)

    Murao, Y.; Araya, F.; Iwamura, T. [Japan Atomic Energy Research Institute, Tokai-mura (Japan)

    1995-09-01

    The Japan Atomic Energy Research Institute (JAERI) proposed a passive safety reactor system concept, JPSR, which was developed for reducing manpower in operation and maintenance and influence of human errors on reactor safety. In the concept the system was extremely simplified. The inherent matching nature of core generation and heat removal rate within a small volume change of the primary coolant is introduced by eliminating chemical shim and adopting in-vessel control rod drive mechanism units, a low power density core and once-through steam generators. In order to simplify the system, a large pressurizer, canned pumps, passive engineered-safety-features-system (residual heat removal system and coolant injection system) are adopted and the total system can be significantly simplified. The residual heat removal system is completely passively actuated in non-LOCAs and is also used for depressurization of the primary coolant system to actuate accumulators in small break LOCAs and reactor shutdown cooling system in normal operation. All of systems for nuclear steam supply system are built in the containment except for the air coolers as a the final heat sink of the passive residual heat removal system. Accordingly the reliability of the safety system and the normal operation system is improved, since most of residual heat removal system is always working and a heat sink for normal operation system is {open_quotes}safety class{close_quotes}. In the passive coolant injection system, depressurization of the primary cooling system by residual heat removal system initiates injection from accumulators designed for the MS-600 in medium pressure and initiates injection from the gravity driven coolant injection pool at low pressure. Analysis with RETRAN-02/MOD3 code demonstrated the capability of passive load-following, self-power-controllability, cooling and depressurization.

  8. Investigations on passive containment cooling; Untersuchungen zur passiven Containmentkuehlung

    Energy Technology Data Exchange (ETDEWEB)

    Knebel, J.U.; Cheng, X.; Neitzel, H.J.; Erbacher, F.J. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany). Inst. fuer Angewandte Thermo- und Fluiddynamik; Hofmann, F. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany). Projekt Nukleare Sicherheitsforschung

    1997-12-31

    The composite containment design for advanced LWRs that has been examined under the PASCO project is a promising design concept for purely passive decay heat removal after a severe accident. The passive cooling processes applied are natural convection and radiative heat transfer. Heat transfer through the latter process removes at an emission coefficient of 0.9 about 50% of the total heat removed via the steel containment, and thus is an essential factor. The heat transferring surfaces must have a high emission coefficient. The sump cooling concept examined under the SUCO project achieves a steady, natural convection-driven flow from the heat source to the heat sink. (orig./CB) [Deutsch] Das im PASCO Programm untersuchte Verbundcontainment fuer zukuenftige Leichtwasserreaktoren ist ein erfolgversprechendes rein passives System zur Nachwaermeabfuhr nach einem schweren Stoerfall. Die passiven Mechanismen der Waermeuebertragung sind Naturkonvektion und Waermestrahlung. Die durch Waermestrahlung uebertragene Waerme betraegt fuer einen Emissionskoeffizienten von 0.9 etwa 50% der insgesamt ueber das Stahl-Containment abgefuehrten Waerme und ist somit von entscheidender Bedeutung fuer die Nachwaermeabfuhr. Fuer die waermeuebertragenden Oberflaechen ist ein hoher Emissionkoeffizient erforderlich. Das im SUCO Programm untersuchte Sumpfkuehlkonzept realisiert eine stabile Naturkonvektionsstroemung zwischen Waermequelle und Waermesenke. (orig./DG)

  9. Thin Film Photovoltaic/Thermal Solar Panels

    Institute of Scientific and Technical Information of China (English)

    David JOHNSTON

    2008-01-01

    A solar panel is described.in which thin films of semiconductor are deposited onto a metal substrate.The semiconductor-metal combination forms a thin film photovoltaic cell,and also acts as a reflector,absorber tandem, which acts as a solar selective surface,thus enhancing the solar thermal performance of the collector plate.The use of thin films reduces the distance heat is required to flow from the absorbing surface to the metal plate and heat exchange conduits.Computer modelling demonstrated that,by suitable choice of materials,photovohaic efficiency call be maintained,with thermal performance slishtly reduced,compared to that for thermal-only panels.By grading the absorber layer-to reduce the band gap in the lower region-the thermal performance can be improved,approaching that for a thermal-only solar panel.

  10. Ceramics and healthy heating and cooling systems: thermal ceramic panels in buildings. Conditions of comfort and energy demand versus convective systems

    Directory of Open Access Journals (Sweden)

    V. Echarri Iribarren

    2016-12-01

    Full Text Available Porcelain stoneware is a widely used building material. In recent years, its range of uses has expanded to encompass a new spectrum of innovative and inventive applications in architecture. In this research, we analysed the patented Thermal Ceramic Panel. This consists of a thin porcelain stoneware panel that incorporates a capillary system of polypropylene tubes measuring 3.5 mm in diameter embedded in a conductive ceramic interface. The system works with hot or cold water, producing healthy heating and cooling by means of radiant surfaces. Following an initial prototype test in which panels were placed on the walls of an office, we conducted simulations at the University of Alicante Museum using wall, ceiling and baffle panels, having previously monitored the state of the building. Thermal behaviour parameters were analysed and compared with those of other standard finishing materials, obtaining results for thermal comfort and energy savings in comparison with all-air systems.

  11. A passive heat tracer experiment to determine the seasonal variation in residence times in a managed aquifer recharge system with DTS

    NARCIS (Netherlands)

    des Tombe, B.F.; Bakker, M.; Schaars, F; van der Made, KJ; Calje, R; Borst, L.

    2016-01-01

    Targeted provisional session N°8.01 The seasonal variation in residence times is determined in a managed aquifer recharge system using a passive heat tracer test. The managed aquifer recharge system consists of a sequence of alternating elongated recharge basins and rows of recovery wells. The

  12. Experimental and numerical simulation of passive decay heat removal by sump cooling after core melt down

    International Nuclear Information System (INIS)

    Knebel, J.U.; Mueller, U.

    1997-01-01

    This article presents the basic physical phenomena and scaling criteria of passive decay heat removal from a large coolant pool by single-phase natural circulation. The physical significance of the dimensionless similarity groups derived is evaluated. The results are applied to the SUCO program that experimentally and numerically investigates the possibility of a sump cooling concept for future light water reactors. The sump cooling concept is based on passive safety features within the containment. The work is supported by the German utilities and the Siemens AG. The article gives results of temperature and velocity measurements in the 1:20 linearly scaled SUCOS-2D test facility. The experiments are backed up by numerical calculations using the commercial software Fluent. Finally, using the similarity analysis from above, the experimental results of the model geometry are scaled-up to the conditions in the prototype, allowing a statement with regard to the feasibility of the sump cooling concept. (author)

  13. Experimental and numerical simulation of passive decay heat removal by sump cooling after core melt down

    Energy Technology Data Exchange (ETDEWEB)

    Knebel, J.U.; Mueller, U. [Forschungszentrum Karlsruhe - Technik und Umwelt Inst. fuer Angewandte Thermo- und Fluiddynamik (IATF), Karlsruhe (Germany)

    1997-12-31

    This article presents the basic physical phenomena and scaling criteria of passive decay heat removal from a large coolant pool by single-phase natural circulation. The physical significance of the dimensionless similarity groups derived is evaluated. The results are applied to the SUCO program that experimentally and numerically investigates the possibility of a sump cooling concept for future light water reactors. The sump cooling concept is based on passive safety features within the containment. The work is supported by the German utilities and the Siemens AG. The article gives results of temperature and velocity measurements in the 1:20 linearly scaled SUCOS-2D test facility. The experiments are backed up by numerical calculations using the commercial software Fluent. Finally, using the similarity analysis from above, the experimental results of the model geometry are scaled-up to the conditions in the prototype, allowing a statement with regard to the feasibility of the sump cooling concept. (author)

  14. Damage detection and isolation via autocorrelation: a step toward passive sensing

    Science.gov (United States)

    Chang, Y. S.; Yuan, F. G.

    2018-03-01

    Passive sensing technique may eliminate the need of expending power from actuators and thus provide a means of developing a compact and simple structural health monitoring system. More importantly, it may provide a solution for monitoring the aircraft subjected to environmental loading from air flow during operation. In this paper, a non-contact auto-correlation based technique is exploited as a feasibility study for passive sensing application to detect damage and isolate the damage location. Its theoretical basis bears some resemblance to reconstructing Green's function from diffusive wavefield through cross-correlation. Localized high pressure air from air compressor are randomly and continuously applied on the one side surface of the aluminum panels through the air blow gun. A laser Doppler vibrometer (LDV) was used to scan a 90 mm × 90 mm area to create a 6 × 6 2D-array signals from the opposite side of the panels. The scanned signals were auto-correlated to reconstruct a "selfimpulse response" (or Green's function). The premise for stably reconstructing the accurate Green's function requires long sensing times. For a 609.6 mm × 609.6 mm flat aluminum panel, the sensing times roughly at least four seconds is sufficient to establish converged Green's function through correlation. For the integral stiffened aluminum panel, the geometrical features of the panel expedite the formation of the diffusive wavefield and thus shorten the sensing times. The damage is simulated by gluing a magnet onto the panels. Reconstructed Green's functions (RGFs) are used for damage detection and damage isolation based on an imaging condition with mean square deviation of the RGFs from the pristine and the damaged structure and the results are shown in color maps. The auto-correlation based technique is shown to consistently detect the simulated damage, image and isolate the damage in the structure subjected to high pressure air excitation. This technique may be transformed into

  15. AC-600 passive ECRHR system and its research program

    International Nuclear Information System (INIS)

    Chen Bingde; Xiao Zejun; Zhou Renmin; Liu Yiyang

    1997-01-01

    The secondary-side passive emergency core residual heat removal system (ECRHR System) is an important part of AC-600 PWR passive safety system, with which the core decay heat can be removed through nature circulation in primary and secondary system. Since 1991, the program for AC-600 passive ECRHR system has been conducted to investigate its distinct thermal-hydraulic phenomena, heat removal capability, affecting factors, and to develop computer codes. The test facility, designed according to the power/volume simulating law, is a full pressure and temperature operating loop with volume scaling factor of 1/390. It is composed of main loop system, emergence feedwater system, depression system, heat tracing, I and C system and power supply system. A total of sixteen tests is planned in first stage and fifteen of them have been done. The preliminary result analysis showed that the system has efficient heat removal capability in most conditions and some special thermal hydraulic phenomena, for example, flow fluctuation, which has negative impact on system's nature circulation, were identified

  16. A passive solar heater-refrigerator

    International Nuclear Information System (INIS)

    D'Isep, F.; Sertorio, L.

    1983-01-01

    In this paper it is studied the nonequilibrium thermodynamic steady-state behaviour of a model system representing a core surrounded by an envelope in which the envelope interacts with the solar radiation and with an external bath having a given temperature profile. The heat flow between core and envelope can be controlled by varying the thermal conductivity of their interface. It is shown that this system acts as a passive heat pump raising the core average temperature with respect to the average equilibrium value corresponding to a fixed value of the interface conductivity, at the same time flattening its oscillation in time. By changing the time dependence of the conductivity the system vice versa acts as a refrigerator. It is shown how the limits of this performance depend on the passive parameters such as surfaces, conductivities, heat capacities. The periodicity considered in this study is the daily cycle

  17. Sandwich-panels based on penopolisocyanurate and mineral wool

    OpenAIRE

    Burtzeva M.; Mednikova E.

    2017-01-01

    Sandwich panel is a self-supporting structure consisting of two steel zinc-coated profiles with a layer of heat retainer. It is used as roofing and walling material. Widely is used in industrial construction, shopping centres, sports complexes, chilling and freezing chambers, storage buildings and quickly erectable housing. The classical basis of heat-insulating layer (core panel) products is used mineral wool insulation materials. This material is resistant to deformation, non-flammable,...

  18. Heating without heat: Thermodynamics of passive energy filters between finite systems.

    Science.gov (United States)

    Muñoz-Tapia, R; Brito, R; Parrondo, J M R

    2017-09-01

    Passive filters allowing the exchange of particles in a narrow band of energy are currently used in microrefrigerators and energy transducers. In this Rapid Communication, we analyze their thermal properties using linear irreversible thermodynamics and kinetic theory, and discuss a striking phenomenon: the possibility of simultaneously increasing or decreasing the temperatures of two systems without any supply of energy. This occurs when the filter induces a flow of particles whose energy is between the average energies of the two systems. Here we show that this selective transfer of particles does not need the action of any sort of Maxwell demon and can be carried out by passive filters without compromising the second law of thermodynamics. This phenomenon allows us to design cycles between two reservoirs at temperatures T_{1}

  19. Studies on the characteristics of the separated type heat pipe system with non-condensible gas for the use of the passive decay heat removal in reactor systems

    International Nuclear Information System (INIS)

    Hayashi, Takao; Iigaki, Kazuhiko; Ohashi, Kazutaka; Hayakawa, Hitoshi; Yamada, Masao.

    1995-01-01

    This study is the fundamental research by experiments to aim at the development of the complete passive decay heat removal system on the modular reactor systems by the form of the separated type of heat pipe system utilizing the features of both the big latent heat for vaporization from water to steam and easy transportation characteristics. Special intention in our study on the fundamental experiments is to look for the effects in such a separated type of heat pipe system to introduce non-condensible gas such as nitrogen gas together with the working fluid of water. Many interesting findings have been obtained so far on the experiments for the variable conductance heat pipe characteristics from viewpoint of the actual application on the aim said above. This study has been carried out by the joint study between Tokai University and Fuji Electric Co., Ltd. and this paper is made up from the several papers presented so far at both the national and international symposiums under the name of joint study of the both bodies. (author)

  20. Experiments of cooling photovoltaic panel by desorption process; Dacchaku hanno wo riyoshita taiyoko hatsuden panel no ondo josho yokusei jikken

    Energy Technology Data Exchange (ETDEWEB)

    Akisawa, A; Inoue, S; Kashiwagi, T [Tokyo University of Agriculture and Technology, Tokyo (Japan)

    1997-11-25

    It is important to cool a photovoltaic (PV) panel, because increased panel temperature is accompanied by decreased power generation efficiency. The authors have proposed a PV power generation system combined with an adsorption chiller driven by low-temperature heat, and simulated temperature changes during the desorption cycle, where the chiller utilizes endothermic reactions of an adsorbent during the desorption cycle. Described herein are results of the tests carried out to validate possibility of controlling panel temperature increase. The system consists of the PV panel with which a bed packed with an adsorbent is monolithically combined, condenser and evaporator. It generates power during the daytime by sunbeams, and provides low-temperature heat during the nighttime by the evaporator. In particular, ice can be produced when methanol and activated coal are used as the adsorbate and adsorbent. It has an advantage of effective utilization of energy as the heat source, which has been merely dissipated by the conventional system in the air. Such a system is expected to be useful for promoting effective utilization of solar energy and for peak power shaving in summer. The initial targets are achieved by the tests. 4 refs., 10 figs.

  1. Thermal Insulating Concrete Wall Panel Design for Sustainable Built Environment

    Science.gov (United States)

    Zhou, Ao; Wong, Kwun-Wah

    2014-01-01

    Air-conditioning system plays a significant role in providing users a thermally comfortable indoor environment, which is a necessity in modern buildings. In order to save the vast energy consumed by air-conditioning system, the building envelopes in envelope-load dominated buildings should be well designed such that the unwanted heat gain and loss with environment can be minimized. In this paper, a new design of concrete wall panel that enhances thermal insulation of buildings by adding a gypsum layer inside concrete is presented. Experiments have been conducted for monitoring the temperature variation in both proposed sandwich wall panel and conventional concrete wall panel under a heat radiation source. For further understanding the thermal effect of such sandwich wall panel design from building scale, two three-story building models adopting different wall panel designs are constructed for evaluating the temperature distribution of entire buildings using finite element method. Both the experimental and simulation results have shown that the gypsum layer improves the thermal insulation performance by retarding the heat transfer across the building envelopes. PMID:25177718

  2. Experimental research progress on passive safety systems of Chinese advanced PWR

    International Nuclear Information System (INIS)

    Xiao Zejun; Zhuo Wenbin; Zheng Hua; Chen Bingde; Zong Guifang; Jia Dounan

    2003-01-01

    TMI and Chernobyl accidents, having pronounced impact on nuclear industries, triggered the governments as well as interested institutions to devote much attention to the safety of nuclear power plant and public's requirements on nuclear power plant safety were also going to be stricter and stricter. It is obvious that safety level of an ordinary light water reactor is no longer satisfactory to these requirements. Recently, the safety authorities have recommended the implementation of passive system to improve the safety of nuclear reactors. Passive safety system is one of the main differences between Chinese advanced PWR and other conventional PWR. The working principle of passive safety system is to utilize the gravity, natural convection (natural circulation) and stored energy to implement the system's safety function. Reactors with passive safety systems are not only safer, but also more economical. The passive safety system of Chinese advanced PWR is composed of three independent systems, i.e. passive containment cooling system, passive residual heat removal system and passive core makeup tank injection system. This paper is a summary of experimental research progress on passive containment cooling system, passive residual heat removal system and passive core makeup tank injection system

  3. Advanced Ultrasupercritical (AUSC) Tube Membrane Panel Development

    Energy Technology Data Exchange (ETDEWEB)

    Pschirer, James [Alstom Power Inc., Windsor, CT (United States); Burgess, Joshua [Alstom Power Inc., Windsor, CT (United States); Schrecengost, Robert [Alstom Power Inc., Windsor, CT (United States)

    2017-08-16

    Alstom Power Inc., a wholly owned subsidiary of the General Electric Company (GE), has completed the project “Advanced Ultrasupercritical (AUSC) Tube Membrane Panel Development” under U.S. Department of Energy (DOE) Award Number DE-FE0024076. This project was part of DOE’s Novel Crosscutting Research and Development to Support Advanced Energy Systems program. AUSC Tube Membrane Panel Development was a two and one half year project to develop and verify the manufacturability and serviceability of welded tube membrane panels made from high performance materials suitable for the AUSC steam cycles, defined as high pressure steam turbine inlet conditions of 700-760°C (1292-1400°F) and 24.5-35MPa (3500-5000psi). The difficulty of this challenge lies in the fact that the membrane-welded construction imposes demands on the materials that are unlike any that exist in other parts of the boiler. Tube membrane panels have been designed, fabricated, and installed in boilers for over 50 years with relatively favorable experience when fabricated from carbon and Cr-Mo low alloy steels. The AUSC steam cycle requires membrane tube panels fabricated from materials that have not been used in a weldment with metal temperatures in the range of 582-610°C (1080-1130°F). Fabrication materials chosen for the tubing were Grade 92 and HR6W. Grade 92 is a creep strength enhanced ferritic Cr-Mo alloy and HR6W is a high nickel alloy. Once the materials were chosen, GE performed the engineering design of the panels, prepared shop manufacturing drawings, and developed manufacturing and inspection plans. After the materials were purchased, GE manufactured and inspected the tube membrane panels, determined if post fabrication heat treatment of the tube membrane panels was needed, performed pre- and post-weld heat treatment on the Grade 92 panels, conducted final nondestructive inspection of any heat treated tube membrane panels, conducted destructive inspection of the completed tube

  4. Review: heat pipe heat exchangers at IROST

    OpenAIRE

    E. Azad

    2012-01-01

    The use of the heat pipe as a component in a heat recovery device has gained worldwide acceptance. Heat pipes are passive, highly reliable and offer high heat transfer rates. This study summarizes the investigation of different types of heat pipe heat recovery systems (HPHRSs). The studies are classified on the basis of the type of the HPHRS. This research is based on 30 years of experience on heat pipe and heat recovery systems that are presented in this study. Copyright , Oxford University ...

  5. The use of segregated heat sink structures to achieve enhanced passive cooling for outdoor wireless devices

    International Nuclear Information System (INIS)

    O'Flaherty, K; Punch, J

    2014-01-01

    Environmental standards which govern outdoor wireless equipment can stipulate stringent conditions: high solar loads (up to 1 kW/m 2 ), ambient temperatures as high as 55°C and negligible wind speeds (0 m/s). These challenges result in restrictions on power dissipation within a given envelope, due to the limited heat transfer rates achievable with passive cooling. This paper addresses an outdoor wireless device which features two segregated heat sink structures arranged vertically within a shielded chimney structure: a primary sink to cool temperature-sensitive components; and a secondary sink for high power devices. Enhanced convective cooling of the primary sink is achieved due to the increased mass flow within the chimney generated by the secondary sink. An unshielded heat sink was examined numerically, theoretically and experimentally, to verify the applicability of the methods employed. Nusselt numbers were compared for three cases: an unshielded heat sink; a sink located at the inlet of a shield; and a primary heat sink in a segregated structure. The heat sink, when placed at the inlet of a shield three times the length of the sink, augmented the Nusselt number by an average of 64% compared to the unshielded case. The Nusselt number of the primary was found to increase proportionally with the temperature of the secondary sink, and the optimum vertical spacing between the primary and secondary sinks was found to be close to zero, provided that conductive transfer between the sinks was suppressed.

  6. Feasibility study on emergency passive habitability systems of SPWR

    International Nuclear Information System (INIS)

    Obata, H.; Tabata, H.; Urakami, M.; Naito, T.

    2000-01-01

    The major characteristic of the Simplified Pressurized Water Reactor (SPWR) is that safety systems for the emergency core cooling and the core decay heat removal functions are achieved by passive equipment. The AP600 developed in the U.S adopts passive emergency habitability system for the main control room (MCR) and the electrical equipment rooms (EER) by using the concrete of the structures as a heat sink. For the SPWR, alternative natural circulation cooling systems have been investigated: for MCR cooling, a cold water reservoir is used as heat sink; for EER cooling, outside air is instead employed. The distribution of the air-velocity and temperature in those rooms were calculated by using a three-dimensional thermal fluid analysis code. The authors verified the conceptual feasibility of these systems as the emergency passive habitability systems in the SPWR. (author)

  7. Evaporation and condensation heat transfer in a suppression chamber of the water wall type passive containment cooling system

    International Nuclear Information System (INIS)

    Fujii, Tadashi; Kataoka, Yoshiyuki; Murase, Michio

    1996-01-01

    To evaluate the system pressure response of a water wall type containment cooling system, which is one of the passive safety systems, the evaporation and condensation behaviors in a suppression chamber have been experimentally examined. In the system, the suppression pool water evaporates from the pool surface, passing into the wetwell due to pool temperature rise, while steam in the wetwell condenses on the steel containment vessel wall due to the heat release through the wall. The wetwell is a gas phase region in the suppression chamber and its pressure, which is expressed as the sum of the noncondensable gas pressure and saturated steam pressure, is strongly affected by the evaporation heat transfer from the suppression pool surface and condensation heat transfer on the containment vessel wall. Based on the measured temperature profiles near the heat transfer surface and the wetwell pressure using two apparatuses, evaporation and condensation heat transfer coefficients were evaluated. The following results were obtained. (1) Both heat transfer coefficients increased as the ratio of the steam partial pressure to the total pressure increased. (2) Comparison of the results from two types of test apparatuses confirmed that the size of the heat transfer surface did not affect the heat transfer characteristics within these tests. (3) The heat transfer coefficients were expressed by the ratio of the steam to noncondensable gas logarithmic mean concentration, which considered the steam and gas concentration gradient from the heat transfer surface to the wetwell bulk. (author)

  8. Technical - Economic Research for Passive Buildings

    Science.gov (United States)

    Miniotaite, Ruta

    2017-10-01

    A newly constructed passive house must save 80 % of heat resources; otherwise it is not a passive house. The heating energy demand of a passive building is less than 15 kWh/m2 per year. However, a passive house is something more than just an energy-saving house. This concept involves sustainable, high-quality, valuable, healthy and durable construction. Features of a passive house: high insulation of envelope components, high-quality windows, good tightness of the building, regenerative ventilation system and elimination of thermal bridges. The Energy Performance of Buildings Directive (EPBD) 61 requires all new public buildings to become near-zero energy buildings by 2019 and will be extended to all new buildings by 2021. This concept involves sustainable, high-quality, valuable, healthy and durable construction. Foundation, walls and roofs are the most essential elements of a house. The type of foundation for a private house is selected considering many factors. The article examines technological and structural solutions for passive buildings foundation, walls and roofs. The technical-economic comparison of the main structures of a passive house revealed that it is cheaper to install an adequately designed concrete slab foundation than to build strip or pile foundation and the floor separately. Timber stud walls are the cheapest wall option for a passive house and 45-51% cheaper compared to other options. The comparison of roofs and ceilings showed that insulation of the ceiling is 25% more efficient than insulation of the roof. The comparison of the main envelope elements efficiency by multiple-criteria evaluation methods showed that it is economically feasible to install concrete slab on ground foundation, stud walls with sheet cladding and a pitched roof with insulated ceiling.

  9. Hovering in the heat: effects of environmental temperature on heat regulation in foraging hummingbirds.

    Science.gov (United States)

    Powers, Donald R; Langland, Kathleen M; Wethington, Susan M; Powers, Sean D; Graham, Catherine H; Tobalske, Bret W

    2017-12-01

    At high temperature (greater than 40°C) endotherms experience reduced passive heat dissipation (radiation, conduction and convection) and increased reliance on evaporative heat loss. High temperatures challenge flying birds due to heat produced by wing muscles. Hummingbirds depend on flight for foraging, yet inhabit hot regions. We used infrared thermography to explore how lower passive heat dissipation during flight impacts body-heat management in broad-billed ( Cynanthus latirostris , 3.0 g), black-chinned ( Archilochus alexandri , 3.0 g), Rivoli's ( Eugenes fulgens , 7.5 g) and blue-throated ( Lampornis clemenciae , 8.0 g) hummingbirds in southeastern Arizona and calliope hummingbirds ( Selasphorus calliope , 2.6 g) in Montana. Thermal gradients driving passive heat dissipation through eye, shoulder and feet dissipation areas are eliminated between 36 and 40°C. Thermal gradients persisted at higher temperatures in smaller species, possibly allowing them to inhabit warmer sites. All species experienced extended daytime periods lacking thermal gradients. Broad-billed hummingbirds lacking thermal gradients regulated the mean total-body surface temperature at approximately 38°C, suggesting behavioural thermoregulation. Blue-throated hummingbirds were inactive when lacking passive heat dissipation and hence might have the lowest temperature tolerance of the four species. Use of thermal refugia permitted hummingbirds to tolerate higher temperatures, but climate change could eliminate refugia, forcing distributional shifts in hummingbird populations.

  10. Experimental and numerical simulation of passive decay heat removal by sump cooling after cool melt down

    International Nuclear Information System (INIS)

    Knebel, J.U.; Kuhn, D.; Mueller, U.

    1997-01-01

    This article presents the basic physical phenomena and scaling criteria of passive decay heat removal from a large coolant pool by single-phase and two-phase natural circulation. The physical significance of the dimensionless similarity groups derived is evaluated. The above results are applied to the SUCO program that is performed at the Forschungszentrum Karlsruhe. The SUCO program is a three-step series of scaled model experiments investigating the possibility of a sump cooling concept for future light water reactors. The sump cooling concept is based on passive safety features within the containment. The work is supported by the German utilities and the Siemens AG. The article gives results of temperature and velocity measurements in the 1:20 linearly scaled SUCOS-2D test facility. The experiments are backed up by numerical calculations using the commercial software package Fluent. Finally, using the similarity analysis from above, the experimental results of the model geometry are scaled-up to the conditions in the prototype, allowing a first statement with regard to the feasibility of the sump cooling concept. 11 refs., 9 figs., 3 tabs

  11. Coupled thermal model of photovoltaic-thermoelectric hybrid panel for sample cities in Europe

    DEFF Research Database (Denmark)

    Rezaniakolaei, Alireza; Sera, Dezso; Rosendahl, Lasse Aistrup

    2016-01-01

    of the hybrid system under different weather conditions. The model takes into account solar irradiation, wind speed and ambient temperature as well as convective and radiated heat losses from the front and rear surfaces of the panel. The model is developed for three sample cities in Europe with different......In general, modeling of photovoltaic-thermoelectric (PV/TEG) hybrid panels have been mostly simplified and disconnected from the actual ambient conditions and thermal losses from the panel. In this study, a thermally coupled model of PV/TEG panel is established to precisely predict performance...... weather conditions. The results show that radiated heat loss from the front surface and the convective heat loss due to the wind speed are the most critical parameters on performance of the hybrid panel performance. The results also indicate that, with existing thermoelectric materials, the power...

  12. Deep influence of passive low energy consumption multi-storey residential building in cold region

    Science.gov (United States)

    Shuai, Zhang; Lihua, Zhao; Rong, Jin; Dong, Junyan

    2018-02-01

    The example of passive architecture demonstration building in Jilin Province, China, based on the practical experience of this project, the control index of passive and low energy consumption residential buildings in cold and passive buildings is referenced by reference to the German construction standard and the Chinese residence construction document, “passive ultra-low energy consumption green Building Technology Guide (Trial)”. The requirement of passive low energy residential buildings on the ground heat transfer coefficient limits is determined, and the performance requirements of passive residential buildings are discussed. This paper analyzes the requirement of the passive low energy residential building on the ground heat transfer coefficient limit, and probes into the influence factors of the ground thermal insulation of the passive low energy consumption residential building. The construction method of passive low energy consumption residential building is proposed.

  13. ESBWR passive heat exchanger design and performance - reducing plant development costs

    International Nuclear Information System (INIS)

    Lumini, E.; Upton, H.A.; Billig, P.F.; Masoni, P.

    1996-01-01

    The EUROPEAN Simplified Boiling Water Reactor (ESBWR) is a nuclear plant that builds on the solid technological foundation of the Simplified Boiling Reactor (SBWR) design. The major objective of the ESBWR program is to develop a plant design that utilizes the basic simplicity of the SBWR design that utilizes the basic simplicity of the SBWR design features to improve overall economics and to meet the specific requirements found in the European Utility Requirements Documents (EUR). The design is being developed by an international team of utilities, designers and researchers with the objective of meeting European utility and regulatory requirements. The overall approach to improve the commercial attractiveness of the ESBWR compared to the SBWR was to take advantage of the modular design of the passive safety system, the economy of scale, as well as the advantage of simpler systems of the passive plant to reduce overall material quantities and improve plant economics. To take advantage of the economy of scale, the power level of ESBWR was increased to 1190 MWe. Because of the modular nature of the passive safety systems in SBWR, in increase in thermal power of ESBWR to 3613 MWt only requires that the number of Passive Containment Condensers to maintain the passive safety features of ESBWR to four 33 MWt units for ESBWR. This paper reviews the Passive Containment Cooling (PCC) and Isolation Condenser (IC) unit design and addresses their use in the passive safety systems of the 3613 MWt ESBWR. The specific design differences and the applicability of the test completed at the SIET PANTHERS test facility in Piacenza, Italy are addressed as well as outlining additional qualification tests that must be completed on the PCC and IC unit design if they are to used in the passive safety systems of the ESBWR. This paper outlines the test results obtained from the prototype PCC and IC PANTHERS tests facility in Piacenza, Italy which have been used to design the ESBWR PCC/1C

  14. Safety significance of ATR passive safety response attributes

    International Nuclear Information System (INIS)

    Atkinson, S.A.

    1990-01-01

    The Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory was designed with some passive safety response attributes which contribute to the safety of the facility. The three passive safety attributes being evaluated in the paper are: 1) In-core and in-vessel natural convection cooling, 2) a passive heat sink capability of the ATR primary coolant system (PCS) for the transfer of decay power from the uninsulated piping to the confinement, and 3) gravity feed of emergency coolant makeup. The safety significance of the ATR passive safety response attributes is that the reactor can passively respond to most transients, given a reactor scram, to provide adequate decay power removal and a significant time for operator action should the normal active heat removal systems and their backup systems both fail. The ATR Interim Level 1 Probabilistic Risk Assessment (PRA) models and results were used to evaluate the significance to ATR fuel damage frequency (or probability) of the above three passive response attributes. The results of the evaluation indicate that the first attribute is a major safety characteristic of the ATR. The second attribute has a noticeable but only minor safety significance. The third attribute has no significant influence on the ATR firewater injection system (emergency coolant system)

  15. Certification of passive houses : A Western European overview

    NARCIS (Netherlands)

    Mlecnik, E.; Kaan, H.; Hodgson, G.

    2008-01-01

    According to the popular definition, passive houses have to reach a target energy demand for heating less than 15 kWh per square meter and per year. This criterion is used as a basis for quality assurance procedures and certification of passive house projects. This paper identifies the experiences

  16. Scottish Passive House: Insights into Environmental Conditions in Monitored Passive Houses

    Directory of Open Access Journals (Sweden)

    Janice Foster

    2016-04-01

    Full Text Available Climate change and sustainability legislation in recent years has led to significant changes in construction approaches in the UK housing sector. This has resulted in the adoption of new building typologies, including the German Passivhaus (Passive House standard. This standard aims to improve occupant comfort and energy efficiency, potentially changing the ways in which homes operate and how occupants interact with them. With increasing construction of low energy dwellings, there is an emerging gap in knowledge in relation to occupant health and wellbeing, thermal comfort, and indoor air quality (IAQ. Using data collected from a two year Building Performance Evaluation (BPE study funded by Innovate UK, the environmental data (temperature, relative humidity and carbon dioxide concentrations from five Certified Passive House homes in Scotland was compared. The results demonstrate problems with overheating with peak temperatures exceeding 30 °C. Imbalanced mechanical ventilation with heat recovery (MVHR systems were identified in 80% of the dwellings and inadequate IAQ was found due to poor ventilation. Only one of the Passive Houses studied exhibited thermal conditions and IAQ which were, on the whole within Passive House parameters. This paper outlines the insights and the main issues of Scottish Passive House in the broader context of sustainability.

  17. Passive safety and the advanced liquid metal reactors

    International Nuclear Information System (INIS)

    Hill, D.J.; Pedersen, D.R.; Marchaterre, J.F.

    1988-01-01

    Advanced Liquid Metal Reactors being developed today in the USA are designed to make maximum use of passive safety features. Much of the LMR safety work at Argonne National Laboratory is concerned with demonstrating, both theoretically and experimentally, the effectiveness of the passive safety features. The characteristics that contribute to passive safety are discussed, with particular emphasis on decay heat removal systems, together with examples of Argonne's theoretical and experimental programs in this area

  18. Passive Strategy with Integrated Passive Safety System (IPSS) for DBAs in SBO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Ho; Kim, Jihee; Choi, Jae Young; Jeon, Inseop; Chang, Soon Heung [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2013-10-15

    In this paper, the strategies of coping with DBAs in SBO were proposed by the design with IPSS. Current nuclear power plants adopt emergency strategies using fire truck as a provision of steam generator cooling. However, it has a lot of limitation like water inventory, preparedness and accessibility. In the case of passive strategy by the application of IPSS, faster actions and more efficient performances can be achieved. The application of IPSS implies the preparedness of big water tank which can be used as water supplier, heat sink and filtering medium. The proposed strategies are set under the conservative conditions without AC power. In order to set more realistic and acceptable strategy, the proposed passive strategy has to be combined with the current strategies. The combined strategies can avoid the reiteration and complexity in accidents. Accordingly, the set of operation mode considering action priority with estimating specific conditions is the further work of this research. Removing decay heat is one of the most important issues in safety of nuclear engineering. In the Fukushima accidents, the initial problem was an occurrence of tsunami. It was connected into a station black out (SBO) which lost AC power in site. Finally, SBO with human error induced the failure of decay heat removal. The occurrence of SBO and the failure of decay heat removal imply the questions for solving them. In order to prevent and mitigate SBO, some solutions have been proposed after the Fukushima accident. First of all, physical protection is enhanced to prevent external risks. For example, the tsunami barrier was modified to be higher from 7.5 m to 10 m. The second is to add electrical redundancy to prevent a total loss of electrical power. AAC diesel generators and movable diesel generators are examples for emergency conditions to supply AC power in site. Bunker concept which was proposed in Europe is a representative example. The bunker concept was analyzed to be applied in

  19. Impact of heat load location and strength on air flow pattern with a passive chilled beam system

    Energy Technology Data Exchange (ETDEWEB)

    Kosonen, Risto [Halton Oy, Niittyvillankuja 4, 01510 Vantaa (Finland); Saarinen, Pekka; Koskela, Hannu [Finnish Institute of Occupational Health, Lemminkaisenkatu 14-18 B, 20520 Turku (Finland); Hole, Alex [Arup, Rob Leslie-Carter, Level 10, 201 Kent Street, Sydney, NSW 2000 (Australia)

    2010-01-15

    A passive chilled beam is a source of natural convection, creating a flow of cold air directly into the occupied zone. Experiments were conducted in a mock-up of an office room to study the air velocities in the occupied spaces. In addition, velocity profiles are registered when underneath heat loads exist and the cool and warm air flows interact. Experimental laboratory study revealed that in the case of the underneath heat gains, even no upward plume was generated and the dummy only acted as a flow obstacle, having a significant effect on the velocity profile. Furthermore, in an actual occupied office environment, the thermal plumes and the supply air diffuser mixed effectively the whole air volume. The maximum air velocity measured was still below 0.25 m/s with the extremely high heat gain of 164 W/m{sup 2}. The results demonstrate that analysis methods were the interaction of convection flow and jet are not taken into account could not accurately describe air movement and draught risk in the occupied room space. (author)

  20. Performance comparison of two types of technologies associated with a positive energy building

    DEFF Research Database (Denmark)

    Dumont, Olivier; Carmo, Carolina; Randaxhe, François

    2015-01-01

    the annual performance of two competing systems. First, a conventional solution, consisting of a passive house coupled with a water to water heat pump and photovoltaic panels (HP/PV). On the other hand, a passive house with a solar thermal roof combined with a reversible heat pump unit / organic Rankine...

  1. SBO simulations for Integrated Passive Safety System (IPSS) using MARS

    International Nuclear Information System (INIS)

    Kim, Sang Ho; Jeong, Sung Yeop; Chang, Soon Heung

    2012-01-01

    The current nuclear power plants have lots of active safety systems with some passive safety systems. The safety of current and future nuclear power plants can be enhanced by the application of additional passive safety systems for the ultimate safety. It is helpful to install the passive safety systems on current nuclear power plants without the design change for the licensibility. For solving the problem about the system complexity shown in the Fukushima accidents, the current nuclear power plants are needed to be enhanced by an additional integrated and simplified system. As a previous research, the integrated passive safety system (IPSS) was proposed to solve the safety issues related with the decay heat removal, containment integrity and radiation release. It could be operated by natural phenomena like gravity, natural circulation and pressure difference without AC power. The five main functions of IPSS are: (a) Passive decay heat removal, (b) Passive emergency core cooling, (c) Passive containment cooling, (d) Passive in vessel retention and ex-vessel cooling, and (e) Filtered venting and pressure control. The purpose of this research is to analyze the performances of each function by using MARS code. The simulated accident scenarios were station black out (SBO) and the additional accidents accompanied by SBO

  2. Design and transient analyses of emergency passive residual heat removal system of CPR1000

    International Nuclear Information System (INIS)

    Zhang, Y.P.; Qiu, S.Z.; Su, G.H.; Tian, W.X.

    2012-01-01

    Highlights: ► Designing an EPRHRs for CPR1000. ► Developing a RELAP model of the EPRHRs. ► The EPRHRs could take away the decay heat effectively. - Abstract: The steam generator secondary emergency passive residual heat removal system (EPRHRs) is a new design for traditional generation II + reactor CPR1000. The EPRHRs is designed to improve the safety and reliability of CPR1000 by completely or partially replacing traditional emergency water cooling system in the event of the station blackout or loss of heat sink accident. The EPRHRs consists of steam generator (SG), heat exchanger (HX), emergency makeup tank (EMT), cooling water tank (CWT), and corresponding pipes and valves. In order to improve the safety and reliability of CPR1000, the model of the primary loop and the EPRHRs was developed to investigate residual heat removal capability of the EPRHRs and the transient characteristics of the primary loop affected by the EPRHRs using RELAP5/MOD3.4. The transient characteristics of the primary loop and the EPRHRs were calculated in the event of station blackout accident. Sensitivity studies of the EPRHRs were also conducted to investigate the response of the primary loop and the EPRHRs on the main parameters of the EPRHRs. The EPRHRs could supply water to the SG shell side from the EMT successfully. The calculation results showed that the EPRHRs could take away the decay heat from the primary loop effectively, and that the single-phase and two-phase natural circulations were established in the primary loop and EPRHRs loop, respectively. The results also indicated that the effect of isolation valve open time on the transient characteristics of the primary loop was little. However, the effect of isolation valve open time on the EPRHRs condensate flow was relatively greater. The isolation valves should not be opened too rapidly during the isolation valve opening process, and the isolation valve opening time should be greater than 10 s, which could avoid the

  3. Enhanced Passive Cooling for Waterless-Power Production Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Salvador B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-06-14

    Recent advances in the literature and at SNL indicate the strong potential for passive, specialized surfaces to significantly enhance power production output. Our exploratory computational and experimental research indicates that fractal and swirl surfaces can help enable waterless-power production by increasing the amount of heat transfer and turbulence, when compared with conventional surfaces. Small modular reactors, advanced reactors, and non-nuclear plants (e.g., solar and coal) are ideally suited for sCO2 coolant loops. The sCO2 loop converts the thermal heat into electricity, while the specialized surfaces passively and securely reject the waste process heat in an environmentally benign manner. The resultant, integrated energy systems are highly suitable for small grids, rural areas, and arid regions.

  4. Experimental investigation of passive thermodynamic vent system (TVS) with liquid nitrogen

    Science.gov (United States)

    Bae, Junhyuk; Yoo, Junghyun; Jin, Lingxue; Jeong, Sangkwon

    2018-01-01

    Thermodynamic vent system (TVS) is an attractive technology to maintain an allowable pressure level of a cryogenic propellant storage in a spacecraft under micro-gravity condition. There are two types of TVS; active or passive. In this paper, the passive TVS which does not utilize a cryogenic liquid circulation pump is experimentally investigated with liquid nitrogen and numerically analyzed by thermodynamic and heat transfer model. A cylindrical copper tank, which is 198 mm in inner diameter and 216 mm in height, is utilized to suppress a thermal-stratification effect of inside cryogenic fluid. A coil heat exchanger, which is 3 m in length and 6.35 mm in outer diameter, and a fixed size orifice of which diameter is 0.4 mm are fabricated to remove heat from the stored fluid to the vented flow. Each vent process is initiated at 140 kPa and ended at 120 kPa with liquid nitrogen fill levels which are 30%, 50% and 70%, respectively. In the numerical model, the fluid in the tank is assumed to be homogeneous saturated liquid-vapor. Mass and energy balance equations with heat transfer conditions suggested in this research are considered to calculate the transient pressure variation in the tank and the amount of heat transfer across the heat exchanger. We achieve the average heat rejection rate of more than 9 W by TVS and conclude that the passive TVS operates satisfactorily. In addition, the prediction model is verified by experimental results. Although the model has limitation in providing accurate results, it can surely predict the tendency of pressure and temperature changes in the tank. Furthermore, the model can suggest how we can improve the heat exchanger design to enhance an overall efficiency of passive TVS. Moreover, the performance of passive TVS is compared with other cryogenic vent systems (direct vent system and active TVS) by suggested performance indicator.

  5. Feasibility test of the concept of long-term passive cooling system of emergency cooldown tank

    International Nuclear Information System (INIS)

    Kim, Myoung Jun; Moon, Joo Hyung; Bae, Youngmin; Kim, Young In; Lee, Hee Joon

    2015-01-01

    Highlights: • The concept of long-term passive cooling system of emergency cooldown tank (ECT). • Existing natural circulation of steam from ECT and measurement of its condensing flow. • Evaluation of cooling capacity and heat transfer of air-cooled condensing heat exchanger. - Abstract: When a passive cooling system is activated in the accident of a nuclear reactor, the water in the emergency cooldown tank of that system will eventually be fully depleted by evaporation. If, however, the evaporating water could be returned to the tank through an air-cooled condensing heat exchanger mounted on top of the tank, the passive cooling system could provide cooling for an extended period. This feasibility of new concept of long-term passive cooling with an emergency cooldown tank was tested by performing an energy balance test with a scaled-down experimental setup. As a result, it was determined that a naturally circulating steam flow can be used to refill the tank. For an air-cooled heat exchanger, the cooling capacity and air-side natural convective heat transfer coefficient were obtained to be 37% of the heat load and between 9 and 10.2 W/m 2 /K depending on the heat load, respectively. Moreover, it was clearly verified that the water level in the emergency cooldown tank could be maintained over the long-term operation of the passive cooling system

  6. Multiple mechanisms quench passive spiral galaxies

    Science.gov (United States)

    Fraser-McKelvie, Amelia; Brown, Michael J. I.; Pimbblet, Kevin; Dolley, Tim; Bonne, Nicolas J.

    2018-02-01

    We examine the properties of a sample of 35 nearby passive spiral galaxies in order to determine their dominant quenching mechanism(s). All five low-mass (M⋆ environments. We postulate that cluster-scale gas stripping and heating mechanisms operating only in rich clusters are required to quench low-mass passive spirals, and ram-pressure stripping and strangulation are obvious candidates. For higher mass passive spirals, while trends are present, the story is less clear. The passive spiral bar fraction is high: 74 ± 15 per cent, compared with 36 ± 5 per cent for a mass, redshift and T-type matched comparison sample of star-forming spiral galaxies. The high mass passive spirals occur mostly, but not exclusively, in groups, and can be central or satellite galaxies. The passive spiral group fraction of 74 ± 15 per cent is similar to that of the comparison sample of star-forming galaxies at 61 ± 7 per cent. We find evidence for both quenching via internal structure and environment in our passive spiral sample, though some galaxies have evidence of neither. From this, we conclude no one mechanism is responsible for quenching star formation in passive spiral galaxies - rather, a mixture of mechanisms is required to produce the passive spiral distribution we see today.

  7. The investigation of Passive Accident Mitigation Scheme for advanced PWR NPP

    International Nuclear Information System (INIS)

    Shi, Er-bing; Fang, Cheng-yue; Wang, Chang; Xia, Geng-lei; Zhao, Cui-na

    2015-01-01

    Highlights: • We put forward a new PAMS and analyze its operation characteristics under SBO. • We conduct comparative analysis between PAMS and Traditional Secondary Side PHRS. • The PAMS could cope with SBO accident and maintain the plant in safe conditions. • PAMS could decrease heat removal capacity of PHRS. • PAMS has advantage in reducing cooling rate and PCCT temperature rising amplitude. - Abstract: To enhance inherent safety features of nuclear power plant, the advanced pressurized water reactors implement a series of passive safety systems. This paper puts forward and designs a new Passive Accident Mitigation Scheme (PAMS) to remove residual heat, which consists of two parts: the first part is Passive Auxiliary Feedwater System (PAFS), and the other part is Passive Heat Removal System (PHRS). This paper takes the Westinghouse-designed Advanced Passive PWR (AP1000) as research object and analyzes the operation characteristics of PAMS to cope with the Station Blackout Accident (SBO) by using RELAP5 code. Moreover, the comparative analysis is also conducted between PAMS and Traditional Secondary Circuit PHRS to derive the advantages of PAMS. The results show that the designed scheme can remove core residual heat significantly and maintain the plant in safe conditions; the first part of PAMS would stop after 120 min and the second part has to come into use simultaneously; the low pressurizer (PZR) pressure signal would be generated 109 min later caused by coolant volume shrinkage, which would actuate the Passive Safety Injection System (PSIS) to recovery the water level of pressurizer; the flow instability phenomenon would occur and last 21 min after the PHRS start-up; according to the comparative analysis, the coolant average temperature gradient and the Passive Condensate Cooling Tank (PCCT) water temperature rising amplitude of PAMS are lower than those of Traditional Secondary Circuit PHRS

  8. Automation of heating system with heat pump

    OpenAIRE

    Ferdin, Gašper

    2016-01-01

    Because of high prices of energy, we are upgrading our heating systems with newer, more fuel efficient heating devices. Each new device has its own control system, which operates independently from other devices in a heating system. With a relatively low investment costs in automation, we can group devices in one central control system and increase the energy efficiency of a heating system. In this project, we show how to connect an oil furnace, a sanitary heat pump, solar panels and a heat p...

  9. Analyses results of the EHF FW Panel with welded fingers

    International Nuclear Information System (INIS)

    Sviridenko, M.N.; Leshukov, A.Yu.; Razmerov, A.V.; Tomilov, S.N.; Danilov, I.V.; Strebkov, Yu.S.; Mazul, I.V.; Labusov, A.; Gervash, A.A.; Belov, A.V.; Semichev, D.

    2014-01-01

    Highlights: • The design of FW panel with welded fingers has been developed. • The FW panel with welded fingers has been analyzed. • The pressure drop in FW panel coolant path do not exceed allowable one. • The mass flow rate distribution between finger pairs are on acceptable level. • Temperatures in FW components do not exceed allowable one. - Abstract: According to Procurement Arrangement (PA) Russian Federation will procure 40% of enhanced heat flux first wall (FW) panels. The signing of PA is scheduled on November 2013. In framework of PA preparation the RF specialists perform EHF FW design optimization in order to provide the ability to operation of EHF FW panel under ITER conditions. This article contains the design description of EHF FW 14 developed by RF and following analysis have been performed: • Hydraulic analysis; • Transient thermal analysis; • Structural analysis. Analyses results show that new design of FW panel with two straight welds for finger fixation on FW beam developed by RF specialists can be used as a reference design for ITER blanket EHF FW panel loaded by 5 MW/m 2 peak heat flux

  10. Passive safety features for next generation CANDU power plants

    International Nuclear Information System (INIS)

    Natalizio, A.; Hart, R.S.; Lipsett, J.J.; Soedijono, P.; Dick, J.E.

    1989-01-01

    CANDU offers an evolutionary approach to simpler and safer reactors. The CANDU 3, an advanced CANDU, currently in the detailed design stage, offers significant improvements in the areas of safety, design simplicity, constructibility, operability, maintainability, schedule and cost. These are being accomplished by retaining all of the well known CANDU benefits, and by relying on the use of proven components and technologies. A major safety benefit of CANDU is the moderator system which is separate from the coolant. The presence of a cold moderator reduces the consequences arising from a LOCA or loss of heat sink event. In existing CANDU plants even the severe accident - LOCA with failure of the emergency core cooling system - is a design basis event. Further advances toward a simpler and more passively safe reactor will be made using the same evolutionary approach. Building on the strength of the moderator system to mitigate against severe accidents, a passive moderator cooling system, depending only on the law of gravity to perform its function, will be the next step of development. AECL is currently investigating a number of other features that could be incorporated in future evolutionary CANDU designs to enhance protection against accidents, and to limit off-site consequences to an acceptable level, for even the worst event. The additional features being investigated include passive decay heat removal from the heat transport system, a simpler emergency core cooling system and a containment pressure suppression/venting capability for beyond design basis events. Central to these passive decay heat removal schemes is the availability of a short-term heat sink to provide a decay heat removal capability of at least three days, without any station services. Preliminary results from these investigations confirm the feasibility of these schemes. (author)

  11. Economic analysis of electric heating based on critical electricity price

    Science.gov (United States)

    Xie, Feng; Sun, Zhijie; Zhou, Xinnan; Fu, Chengran; Yang, Jie

    2018-06-01

    The State Grid Corporation of China proposes an alternative energy strategy, which will make electric heating an important task in the field of residential electricity consumption. This article takes this as the background, has made the detailed introduction to the inhabitant electric heating technology, and take the Zhangjiakou electric panels heating technology as an example, from the expense angle, has carried on the analysis to the electric panels heating economy. In the field of residential heating, electric panels operating costs less than gas boilers. After customers implying energy-saving behavior, electric panels operating cost is even lower than coal-fired boilers. The critical price is higher than the execution price, which indicates that the economic performance of the electric panels is significantly higher than that of the coal boiler.

  12. Observation of trapped gas during electrical resistance heating of trichloroethylene under passive venting conditions

    Science.gov (United States)

    Martin, E. J.; Kueper, B. H.

    2011-11-01

    A two-dimensional experiment employing a heterogeneous sand pack incorporating two pools of trichloroethylene (TCE) was performed to assess the efficacy of electrical resistance heating (ERH) under passive venting conditions. Temperature monitoring displayed the existence of a TCE-water co-boiling plateau at 73.4 °C, followed by continued heating to 100 °C. A 5 cm thick gas accumulation formed beneath a fine-grained capillary barrier during and after co-boiling. The capillary barrier did not desaturate during the course of the experiment; the only pathway for gas escape being through perforated wells traversing the barrier. The thickness of the accumulation was dictated by the entry pressure of the perforated well. The theoretical maximum TCE soil concentration within the region of gas accumulation, following gas collapse, was estimated to be 888 mg/kg. Post-heating soil sampling revealed TCE concentrations in this region ranging from 27 mg/kg to 96.7 mg/kg, indicating removal of aqueous and gas phase TCE following co-boiling as a result of subsequent boiling of water. The equilibrium concentrations of TCE in water corresponding to the range of post-treatment concentrations in soil (6.11 mg/kg to 136 mg/kg) are calculated to range from 19.8 mg/l to 440 mg/l. The results of this experiment illustrate the importance of providing gas phase venting during the application of ERH in heterogeneous porous media.

  13. Energy balance in a passive solar building. An attempt at economic assessment

    Directory of Open Access Journals (Sweden)

    Sobczyk Wiktoria

    2016-01-01

    Full Text Available The paper emphasizes possibilities for substantially reducing energy consumption with modern ecofriendly buildings. Passive building construction is a sector of the construction industry that has extremely low demand for the energy for heating house interiors. A passive house requires a small amount of energy to provide thermal comfort, but it requires proper systems (HRU, heat pumps, solar collectors to accomplish that effect. The modification proposal presented in the paper has dramatically reduced the demand for heat capacity of the building. Unfortunately the passive standard has not been reached, but thermomodernisation would allow for a significant reduction of heating costs. The demand per 1 m2 of heated surface area in a traditional building was 41.9 W/m2, while after the modification – only 15.01 W/m2. The tested building, if located in a warmer climate, with an average outside temperature of ≥ -10ºC would certainly perform its function. The use of modern technology ensures high energy savings. Such solutions, however, are not the cheapest on the market, and therefore are less available. The construction of a passive solar buildings is a “green” investment with tangible environmental results. By ensuring the thermomodernisation of a traditional building we can enjoy real environmental and economic benefits.

  14. Experimental investigation on Heat Transfer Performance of Annular Flow Path Heat Pipe

    International Nuclear Information System (INIS)

    Kim, In Guk; Kim, Kyung Mo; Jeong, Yeong Shin; Bang, In Cheol

    2015-01-01

    Mochizuki et al. was suggested the passive cooling system to spent nuclear fuel pool. Detail analysis of various heat pipe design cases was studied to determine the heat pipes cooling performance. Wang et al. suggested the concept PRHRS of MSR using sodium heat pipes, and the transient performance of high temperature sodium heat pipe was numerically simulated in the case of MSR accident. The meltdown at the Fukushima Daiichi nuclear power plants alarmed to the dangers of station blackout (SBO) accident. After the SBO accident, passive decay heat removal systems have been investigated to prevent the severe accidents. Mochizuki et al. suggested the heat pipes cooling system using loop heat pipes for decay heat removal cooling and analysis of heat pipe thermal resistance for boiling water reactor (BWR). The decay heat removal systems for pressurized water reactor (PWR) were suggested using natural convection mechanisms and modification of PWR design. Our group suggested the concept of a hybrid heat pipe with control rod as Passive IN-core Cooling System (PINCs) for decay heat removal for advanced nuclear power plant. Hybrid heat pipe is the combination of the heat pipe and control rod. In the present research, the main objective is to investigate the effect of the inner structure to the heat transfer performance of heat pipe containing neutron absorber material, B 4 C. The main objective is to investigate the effect of the inner structure in heat pipe to the heat transfer performance with annular flow path. ABS pellet was used instead of B 4 C pellet as cylindrical structures. The thermal performances of each heat pipes were measured experimentally. Among them, concentric heat pipe showed the best performance compared with others. 1. Annular evaporation section heat pipe and annular flow path heat pipe showed heat transfer degradation. 2. AHP also had annular vapor space and contact cooling surface per unit volume of vapor was increased. Heat transfer coefficient of

  15. Architectural design of passive solar residential building

    Directory of Open Access Journals (Sweden)

    Ma Jing

    2015-01-01

    Full Text Available This paper studies thermal environment of closed balconies that commonly exist in residential buildings, and designs a passive solar residential building. The design optimizes the architectural details of the house and passive utilization of solar energy to provide auxiliary heating for house in winter and cooling in summer. This design might provide a more sufficient and reasonable modification for microclimate in the house.

  16. Heat stress and fetal risk. Environmental limits for exercise and passive heat stress during pregnancy: a systematic review with best evidence synthesis.

    Science.gov (United States)

    Ravanelli, Nicholas; Casasola, William; English, Timothy; Edwards, Kate M; Jay, Ollie

    2018-03-01

    Pregnant women are advised to avoid heat stress (eg, excessive exercise and/or heat exposure) due to the risk of teratogenicity associated with maternal hyperthermia; defined as a core temperature (T core ) ≥39.0°C. However, guidelines are ambiguous in terms of critical combinations of climate and activity to avoid and may therefore unnecessarily discourage physical activity during pregnancy. Thus, the primary aim was to assess T core elevations with different characteristics defining exercise and passive heat stress (intensity, mode, ambient conditions, duration) during pregnancy relative to the critical maternal T core of ≥39.0°C. Systematic review with best evidence synthesis. EMBASE, MEDLINE, SCOPUS, CINAHL and Web of Science were searched from inception to 12 July 2017. Studies reporting the T core response of pregnant women, at any period of gestation, to exercise or passive heat stress, were included. 12 studies satisfied our inclusion criteria (n=347). No woman exceeded a T core of 39.0°C. The highest T core was 38.9°C, reported during land-based exercise. The highest mean end-trial T core was 38.3°C (95% CI 37.7°C to 38.9°C) for land-based exercise, 37.5°C (95% CI 37.3°C to 37.7°C) for water immersion exercise, 36.9°C (95% CI 36.8°C to 37.0°C) for hot water bathing and 37.6°C (95% CI 37.5°C to 37.7°C) for sauna exposure. The highest individual core temperature reported was 38.9°C. Immediately after exercise (either land based or water immersion), the highest mean core temperature was 38.3°C; 0.7°C below the proposed teratogenic threshold. Pregnant women can safely engage in: (1) exercise for up to 35 min at 80%-90% of their maximum heart rate in 25°C and 45% relative humidity (RH); (2) water immersion (≤33.4°C) exercise for up to 45 min; and (3) sitting in hot baths (40°C) or hot/dry saunas (70°C; 15% RH) for up to 20 min, irrespective of pregnancy stage, without reaching a core temperature exceeding the teratogenic

  17. Analysis of passive moderator cooling system of Candu-6A reactor at emergency condition

    International Nuclear Information System (INIS)

    Umar, Efrizon; Subki, M. Hadid; Vecchiarelli, Jack

    2001-01-01

    Analysis of passive moderator cooling system subject to in-core LOCA with no emergency core cooling injection has been done. In this study, the new model of passive moderator system has been tested for emergency conditions and CATHENA code Mod-3.5b/Rev1 is used to calculate some parameters of this passive moderator cooling system. This result of simulation show that the proposed moderator cooling system have given satisfactory result, especially for the case with 0.7 m riser diameter and the number of heat exchanger tubes 8100. For PEWS tank containing 3000 m3 of light water initially at 30 0C and a 3641 m2 moderator heat exchanger, the average long-term heat removed rate balances the moderator heat load and the flow through the passive moderator loop remains stable for over 72 hours with no saturated boiling in the calandria and flow instabilities do not develop during long-term period

  18. Aerosol Deposition and Solar Panel Performance

    Science.gov (United States)

    Arnott, W. P.; Rollings, A.; Taylor, S. J.; Parks, J.; Barnard, J.; Holmes, H.

    2015-12-01

    Passive and active solar collector farms are often located in relatively dry desert regions where cloudiness impacts are minimized. These farms may be susceptible to reduced performance due to routine or episodic aerosol deposition on collector surfaces. Intense episodes of wind blown dust deposition may negatively impact farm performance, and trigger need to clean collector surfaces. Aerosol deposition rate depends on size, morphology, and local meteorological conditions. We have developed a system for solar panel performance testing under real world conditions. Two identical 0.74 square meter solar panels are deployed, with one kept clean while the other receives various doses of aerosol deposition or other treatments. A variable load is used with automation to record solar panel maximum output power every 10 minutes. A collocated sonic anemometer measures wind at 10 Hz, allowing for both steady and turbulent characterization to establish a link between wind patterns and particle distribution on the cells. Multispectral photoacoustic instruments measure aerosol light scattering and absorption. An MFRSR quantifies incoming solar radiation. Solar panel albedo is measured along with the transmission spectra of particles collected on the panel surface. Key questions are: At what concentration does aerosol deposition become a problem for solar panel performance? What are the meteorological conditions that most strongly favor aerosol deposition, and are these predictable from current models? Is it feasible to use the outflow from an unmanned aerial vehicle hovering over solar panels to adequately clean their surface? Does aerosol deposition from episodes of nearby forest fires impact performance? The outlook of this research is to build a model that describes environmental effects on solar panel performance. Measurements from summer and fall 2015 will be presented along with insights gleaned from them.

  19. Passive houses in Sweden. Experiences from design and construction phase

    Energy Technology Data Exchange (ETDEWEB)

    Jansson, Ulla

    2008-07-01

    The sector of residential buildings and service organizations uses 36% of the total energy in Sweden. In June 2006, it was decided by the Swedish parliament that the energy use in residential buildings and premises should decrease by 20% per heated unit area before 2020. To reach this goal, more energy efficient buildings must be produced as well as energy efficient improvements must be performed on the existing building stock. One way to reduce the energy use in buildings is to build passive houses. A passive house is a mechanically ventilated building that with a highly insulated and air tight building envelope uses a minimum of energy for heating. The method used in this research is to practically participate in four passive house demonstration projects. The results expected are to find guiding principles and tools needed for passive house planning and make the system solutions usable for planning in more general terms. Joining as a part of the planning group; advice and help is given to architects, consultants and to the client. The demonstration projects studied are located in the south-west of Sweden. Three of the projects are new constructions and one is a renovation project. In the centre of Vanirom 40 rental apartments were built in 2005/2006 according to the passive house standard. Solar collectors on the roof contribute to the domestic hot water production. Every apartment has its own mechanical ventilation system with efficient heat recovery. Auxiliary heating is supplied by electricity. The load bearing structure were made of concrete and cast at site. The exterior walls and roof were made of wooden frame construction and mounted at site. The tenants moved in during summer 2006. The passive house project in Failure's consists of three houses with 12 rental apartments. The air is supplied by mechanical ventilation with an air to air heat exchanger, one in each apartment. The domestic hot water is prepared by solar collectors and auxiliary heating

  20. Brookfield Homes Passive House Performance Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Herk, A. [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, A. [IBACOS, Inc., Pittsburgh, PA (United States); Beach, R. [IBACOS, Inc., Pittsburgh, PA (United States)

    2016-02-01

    In 2012-2013, IBACOS worked with a builder, Brookfield Homes in Denver, Colorado, to design and construct a Passive House certified model home. IBACOS used several modeling programs and calculation methods to complete the final design package along with Brookfield's architect KGA Studio. This design package included upgrades to the thermal enclosure, basement insulation, windows, and heating, ventilation, and air conditioning. Short-term performance testing in the Passive House was done during construction and after construction.

  1. Strategy for Passivating Char Efficiently at the Pilot Scale

    Energy Technology Data Exchange (ETDEWEB)

    Dunning, Timothy C [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-01-18

    Fast pyrolysis is a promising pathway for the commercialization of liquid transportation fuels from biomass. Fast pyrolysis is performed at moderate heat (450-600 degrees Celcius) in an oxygen-deficient environment. One of the products of fast pyrolysis is biochar, which is often used as a heat source or as a soil amendment. Biochar is a partially reacted solid that is created in the production of bio-oil during fast pyrolysis. Biochar produced at these conditions contains significant quantities of carbon that adsorb oxygen when exposed to air. Biochar adsorption of oxygen is an exothermic process that may generate sufficient heat for combustion in ambient air. Biochar is also a self-insulating material which compounds the effects of heat generated internally. These factors lead to safety concerns and material handling difficulties. The Thermochemical Process Development Unit at the National Renewable Energy Laboratory operates a pilot plant that may be configured for fast pyrolysis, gasification, and will be introducing catalytic fast pyrolysis capabilities in 2018. The TCPDU designed and installed a system to introduce oxygen to collected biochar systematically for a controlled passivation. Biochar is collected and cooled in an oxygen deficient environment during fast pyrolysis. Oxygen is then introduced to the biochar on a mass flow basis. A sparger imbedded within the biochar sample near the bottom of the bed flows air diluted with nitrogen into the char bed, and excess gasses are removed from the top of the collection drum, above the char bed. Pressure within the collection drum is measured indicating adequate flow through filters. Sample weight is recorded before and after passivation. During passivation, temperature is measured at 18 points within the char bed. Oxygen content and temperature are measured leaving the char bed. Maximum temperature parameters were established to ensure operator safety during biochar passivation. Extensive passivation data was

  2. Solar heating at the P. E. I. Ark

    Energy Technology Data Exchange (ETDEWEB)

    MacKay, K.T.

    1979-01-01

    Both active and passive solar heating systems are employed at the P.E.I. Ark. An active drain-down system, which stores heat in water located in 70,000 litre concrete tanks, supplies heat to the living area. Domestic hot water is heated by a thermosiphon drain-down solar system coupled to a wood cookstove. Environmental design of the Ark allows for maximum use of passive solar energy. The passive system supplies the majority of the heating load on sunny days, while wood stoves supply the back-up heat. The performance of the active system has required high maintenance because of problems in the mechanical and electrical systems. This, coupled with the high initial cost, has not made the system cost effective. The 178m/sup 2/ commercial greenhouse uses a hybrid system with both active and passive systems. The active system employs a fan to draw air through rock storage. The passive system employs the high thermal mass of the deep soil beds, a concrete slab, and most importantly, 53,200 litres of water in translucent tanks. These tanks are then used for fish rearing and are the basis for a solar hatchery. The greenhouse has performed very well, producing crops year round since 1976.

  3. Photovoltaic-Panel Laminator

    Science.gov (United States)

    Keenan, R.

    1985-01-01

    Two-piece unit heats and presses protective layers to form laminate. Rubber diaphragm between upper and lower vacuum chambers alternates between neutral position and one that presses against solar-cell array, supplying distributed force necessary to press layers of laminate together. Encapsulation helps to protect cells from environment and to ensure long panel life while allowing efficient generation of electricity from Sunlight.

  4. Thermal analysis and design of passive solar buildings

    CERN Document Server

    Athienitis, AK

    2013-01-01

    Passive solar design techniques are becoming increasingly important in building design. This design reference book takes the building engineer or physicist step-by-step through the thermal analysis and design of passive solar buildings. In particular it emphasises two important topics: the maximum utilization of available solar energy and thermal storage, and the sizing of an appropriate auxiliary heating/cooling system in conjunction with good thermal control.Thermal Analysis and Design of Passive Solar Buildings is an important contribution towards the optimization of buildings as systems th

  5. Experimental and Numerical Research of the Thermal Properties of a PCM Window Panel

    Directory of Open Access Journals (Sweden)

    Martin Koláček

    2017-07-01

    Full Text Available This paper reports the experimental and simulation analysis of a window system incorporating Phase Change Materials (PCMs. In this study, the latent heat storage material is exploited to increase the thermal mass of the building component. A PCM-filled window can increase the possibilities of storage energy from solar radiation and reduce the heating cooling demand. The presented measurements were performed on a specific window panel that integrates a PCM. The PCM window panel consists of four panes of safety glass with three gaps, of which the first one contains a prismatic glass, the second a krypton gas, and the last one a PCM. New PCM window panel technology uses the placement of the PCM in the whole space of the window cavity. This technology improves the thermal performance and storage mass of the window panel. The results show the incongruent melting of salt hydrates and the high thermal inertia of the PCM window panel. The simulation data showed that the PCM window panel and the double glazing panel markedly reduced the peak temperature on the interior surface, reduced the air temperature inside the room, and also considerably improved the thermal mass of the building. This means that the heat energy entering the building through the panel is reduced by 66% in the summer cycle.

  6. A heating system for piglets in farrowing house using waste heat from biogas engine

    Directory of Open Access Journals (Sweden)

    Payungsak Junyusen

    2008-12-01

    Full Text Available The aim of this study is to design and test a heating system for piglets in farrowing house by utilising the waste heat from a biogas engine as a heat source. The study was separated into three parts: the study on the biogas combined heat and power plant, the investigation on the properties of the heat panel, and the installation and testing of the heating system. From the experiment, the condition producing 60 kW of electrical power was a proper one, in which electrical efficiency and specific fuel consumption were 14% and 1.22 m3/kWh respectively. Generating both electricity and heat increased the overall efficiency to 37.7% and decreased the specific fuel consumption to 0.45 m3/kWh. The heat panel, which was made of a plastic material, had a thermal conductivity of 0.58 W/mC and the maximum compressive force and operating pressure of 8.1 kN and 0.35 bar respectively. The surface temperature of the panel was dependent on the inlet water temperature. When hot water of 44C was supplied into the farrowing house with room temperature of 26C, the average surface temperature was 33C. The developed heating system could provide heat for 4.3 farrowing houses. The payback period of this project was 2.5 years.

  7. Thermal-hydraulic analysis code development and application to passive safety reactor at JAERI

    International Nuclear Information System (INIS)

    Araya, F.

    1995-01-01

    After a brief overview of safety assessment process, the author describes the LOCA analysis code system developed in JAERI. It comprises audit calculation code (WREM, WREM-J2, Japanese own code and BE codes (2D/3D, ICAP, ROSA). The codes are applied to development of Japanese passive safety reactor concept JPSR. Special attention is paid to the passive heat removal system and phenomena considered to occur under loss of heat sink event. Examples of LOCA analysis based on operation of JPSR for the cases of heat removal by upper RHR and heat removal from core to atmosphere are given. Experiments for multi-dimensional flow field in RPV and steam condensation in water pool are used for understanding the phenomena in passive safety reactors. The report is in a poster form only. 1 tab., 13 figs

  8. Active and passive cooling methods for dwellings

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg

    2018-01-01

    In this document a review of three active as well as ten passive cooling methods suitable for residential buildings is carried out. The review firstly addresses how the various technologies cool the space according to the terms of the building heat balance, under what technical conditions...... ventilation, controlled ventilation, roof coating and eco-evaporative cooling are the most suitable passive methods for an extensive use in this country....

  9. Application of water flowing PVC pipe and EPS foam bead as insulation for wall panel

    Science.gov (United States)

    Ali, Umi Nadiah; Nor, Norazman Mohamad; Yusuf, Mohammed Alias; Othman, Maidiana; Yahya, Muhamad Azani

    2018-02-01

    Malaysia located in tropical climate which have a typical temperature range between 21 °C to 36 °C. Due to this, air-conditioning system for buildings become a necessity to provide comfort to occupants. In order to reduce the energy consumption of the air-conditioning system, the transmission of heat from outdoor to indoor space should be kept as minimum as possible. This article discuss about a technology to resist heat transfer through concrete wall panel using a hybrid method. In this research, PVC pipe was embedded at the center of concrete wall panel while the EPS foam beads were added about 1% of the cement content in the concrete mix forming the outer layer of the wall panel. Water is regulated in the PVC pipe from the rainwater harvesting system. The aim of this study is to minimize heat transfer from the external environment into the building. Internal building temperature which indicated in BS EN ISO 7730 or ASHRAE Standard 55 where the comfort indoor thermal is below 25°C during the daytime. Study observed that the internal surface temperature of heat resistance wall panel is up to 3°C lower than control wall panel. Therefore, we can conclude that application of heat resistance wall panel can lead to lower interior building temperature.

  10. A passive heat maintenance strategy implemented during a simulated half-time improves lower body power output and repeated sprint ability in professional Rugby Union players.

    Directory of Open Access Journals (Sweden)

    Mark Russell

    Full Text Available Reduced physical performance has been observed following the half-time period in team sports players, likely due to a decrease in muscle temperature during this period. We examined the effects of a passive heat maintenance strategy employed between successive exercise bouts on core temperature (Tcore and subsequent exercise performance. Eighteen professional Rugby Union players completed this randomised and counter-balanced study. After a standardised warm-up (WU and 15 min of rest, players completed a repeated sprint test (RSSA 1 and countermovement jumps (CMJ. Thereafter, in normal training attire (Control or a survival jacket (Passive, players rested for a further 15 min (simulating a typical half-time before performing a second RSSA (RSSA 2 and CMJ's. Measurements of Tcore were taken at baseline, post-WU, pre-RSSA 1, post-RSSA 1 and pre-RSSA 2. Peak power output (PPO and repeated sprint ability was assessed before and after the simulated half-time. Similar Tcore responses were observed between conditions at baseline (Control: 37.06±0.05°C; Passive: 37.03±0.05°C and for all other Tcore measurements taken before half-time. After the simulated half-time, the decline in Tcore was lower (-0.74±0.08% vs. -1.54±0.06%, p<0.001 and PPO was higher (5610±105 W vs. 5440±105 W, p<0.001 in the Passive versus Control condition. The decline in PPO over half-time was related to the decline in Tcore (r = 0.632, p = 0.005. In RSSA 2, best, mean and total sprint times were 1.39±0.17% (p<0.001, 0.55±0.06% (p<0.001 and 0.55±0.06% (p<0.001 faster for Passive versus Control. Passive heat maintenance reduced declines in Tcore that were observed during a simulated half-time period and improved subsequent PPO and repeated sprint ability in professional Rugby Union players.

  11. Study on Heat Transfer Characteristics of One Side Heated Vertical Channel Applied as Vessel Cooling System

    International Nuclear Information System (INIS)

    Kuriyama, Shinji; Takeda, Tetsuaki; Funatani, Shumpei

    2014-01-01

    The inherent properties of the Very-High-Temperature Reactor facilitate the design of the VHTR with high degree of passive safe performances, compared to other type of reactors. However; it is still not clear if the VHTR can maintain a passive safe function during the severe accident, or what would be a design criterion to guarantee the VHTR with the high degree of passive safe performances during the accidents. In the Very High Temperature Reactor (VHTR) which is a next generation nuclear reactor system, ceramics and graphite are used as a fuel coating material and a core structural material, respectively. Even if the depressurization accident occurs and the reactor power goes up instantly, the temperature of the core will change slowly. This is because the thermal capacity of the core is so large. Therefore, the VHTR system can passively remove the decay heat of the core by natural convection and radiation from the surface of the reactor pressure vessel (RPV). This study is to develop the passive cooling system for the VHTR using the vertical channel inserting porous materials. The objective of this study is to investigate heat transfer characteristics of natural convection of a one-side heated vertical channel inserting the porous materials with high porosity. In order to obtain the heat transfer and fluid flow characteristics of a vertical channel inserting porous material, we have also carried out a numerical analysis using the commercial CFD code. From the analytical results obtained in the natural convection cooling, an amount of removed heat enhanced inserting the copper wire. It was found that an amount of removed heat inserting the copper wire (porosity = 0.9972) was about 10% higher than that without the copper wire. This paper describes a thermal performance of the one-side heated vertical channel inserting copper wire with high porosity. (author)

  12. Effect of excimer laser annealing on a-InGaZnO thin-film transistors passivated by solution-processed hybrid passivation layers

    Science.gov (United States)

    Bermundo, Juan Paolo; Ishikawa, Yasuaki; Fujii, Mami N.; Nonaka, Toshiaki; Ishihara, Ryoichi; Ikenoue, Hiroshi; Uraoka, Yukiharu

    2016-01-01

    We demonstrate the use of excimer laser annealing (ELA) as a low temperature annealing alternative to anneal amorphous InGaZnO (a-IGZO) thin-film transistors (TFTs) passivated by a solution-processed hybrid passivation layer. Usually, a-IGZO is annealed using thermal annealing at high temperatures of up to 400 °C. As an alternative to high temperature thermal annealing, two types of ELA, XeCl (308 nm) and KrF (248 nm) ELA, are introduced. Both ELA types enhanced the electrical characteristics of a-IGZO TFTs leading to a mobility improvement of ~13 cm2 V-1 s-1 and small threshold voltage which varied from ~0-3 V. Furthermore, two-dimensional heat simulation using COMSOL Multiphysics was used to identify possible degradation sites, analyse laser heat localization, and confirm that the substrate temperature is below 50 °C. The two-dimensional heat simulation showed that the substrate temperature remained at very low temperatures, less than 30 °C, during ELA. This implies that any flexible material can be used as the substrate. These results demonstrate the large potential of ELA as a low temperature annealing alternative for already-passivated a-IGZO TFTs.

  13. Trapped in the heat: A post-communist type of fuel poverty

    International Nuclear Information System (INIS)

    Tirado Herrero, Sergio; Ürge-Vorsatz, Diana

    2012-01-01

    Fuel poverty is a still insufficiently researched social and energy challenge with significant climate change implications. Based on evidence from Hungarian panel apartment blocks connected to district heating, this paper introduces a new variant of fuel poverty that may not be properly captured by existing fuel poverty indicators. This newly defined variant can be largely attributed to post-communist legacies – though it might also exist in other contexts – and assumes that consumers living in poor-efficiency, district-heated buildings are trapped in dwellings with adequate indoor temperatures but disproportionately high heating costs because (a) changing supplier or fuel is difficult because of the existing technical and institutional constraints, and (b) they do not realistically have the option to reduce individually their heating costs through individual efficiency improvements. This situation often translates into payment arrears, indebtedness, risk of disconnection, or reduced consumption of other basic goods and services. State-supported policy responses to date have favoured symptomatic solutions (direct consumer support) combined with superficial retrofits, though it is argued that only state-of-the-art retrofits such as the passive house-based SOLANOVA pilot project in Dunaújváros can fully eradicate fuel poverty in this consumer group. - Highlights: ► We identify a new variant of fuel poverty. ► We explore this variant in panel apartment blocks connected to DH in Hungary, where dwellings are warm enough in winter but have disproportionately high energy costs. ► Affected households react in ways that harm their welfare and put them at risk. ► Deep retrofits in dwellings such as these can eradicate fuel poverty while also contributing to other goals.

  14. Industrial Heat Pump for a High Temperature District Heating Application

    DEFF Research Database (Denmark)

    Poulsen, Claus Nørgaard

    by excess thermal energy from thermal solar panels. An industrial heat pump system using the natural refrigerant ammonia, is extracting the thermal energy from the storage when needed, and produce hot water at 85°C, for the district heating grid. The heat pump also acts as contributor to electricity grid...

  15. Thermal control system. [removing waste heat from industrial process spacecraft

    Science.gov (United States)

    Hewitt, D. R. (Inventor)

    1983-01-01

    The temperature of an exothermic process plant carried aboard an Earth orbiting spacecraft is regulated using a number of curved radiator panels accurately positioned in a circular arrangement to form an open receptacle. A module containing the process is insertable into the receptacle. Heat exchangers having broad exterior surfaces extending axially above the circumference of the module fit within arcuate spacings between adjacent radiator panels. Banks of variable conductance heat pipes partially embedded within and thermally coupled to the radiator panels extend across the spacings and are thermally coupled to broad exterior surfaces of the heat exchangers by flanges. Temperature sensors monitor the temperature of process fluid flowing from the module through the heat exchanges. Thermal conduction between the heat exchangers and the radiator panels is regulated by heating a control fluid within the heat pipes to vary the effective thermal length of the heat pipes in inverse proportion to changes in the temperature of the process fluid.

  16. Heat transfer modelling in the vertical tubes of a natural circulation passive containment loop with noncondensable gas

    International Nuclear Information System (INIS)

    Herranz, L.E.; Munoz-Cobo, J.L.; Tachenko, I.; Sancho, J.; Escriva, A.; Verdu, G.

    1994-01-01

    One of the key safety systems of the Simplified Boiling Water Reactor (SBWR) of General Electric is the Passive Containment Cooling System (PCCS). This system is designed to behave as a heat sink without need of operator actions in case of a reactor accident. Such a function relies on setting up a natural circulation loop between drywell and wetwell. Along this loop heat is removed by condensing the steam coming from the drywell onto the inner surface of externally cooled vertical tubes. Therefore, a successful design of the condenser requires a good knowledge of the local heat transmission coefficients. In this paper a model of steam condensation into vertical tubes is presented. Based on a modified diffusion boundary layer approach for noncondensables, this model accounts for the effect of shear stress caused by the cocurrent steam-gas mixture on the liquid film thickness. An approximate method to calculate film thickness, avoiding iterative algorithms, has been proposed. At present, this model has been implemented in HTCPIPE code and its results are being checked in terms of local heat transfer coefficients against the experimental data available. A good agreement between measurements and predictions is being observed for tests at atmospheric pressure. Further development and validation of the model is needed to consider aspects such as mist formation, wavy flow and high pressure. (author)

  17. Design and transient analyses of passive emergency feedwater system of CPR1000. Part 1. Air cooling condition

    International Nuclear Information System (INIS)

    Zhang Yapei; Qiu Suizheng; Su Guanghui; Tian Wenxi; Cao Jianhua; Lu Donghua; Fu Xiangang

    2011-01-01

    The steam generator secondary passive emergency feedwater system is a new design for traditional generation Ⅱ + reactor CPR1000. The passive emergency feedwater system is designed to supply water to the SG shell side and improve the safety and reliability of CPR1000 by completely or partially replacing traditional emergency water cooling system in the event of the feed line break (FLB) or loss of heat sink accident. The passive emergency feedwater system consists of steam generator (SG), heat exchanger (HX), air cooling tower, emergency makeup tank (EMT), and corresponding pipes and valves for air cooling condition. In order to improve the safety and reliability of CPR1000, the model of the primary loop system and the passive emergency feedwater system was developed to investigate residual heat removal capability of the passive emergency feedwater system and the transient characteristics of the primary loop system affected by the passive emergency feedwater system using RELAP5/MOD3.4. The transient characteristics of the primary loop system and the passive emergency feedwater system were calculated in the event of feed line break accident. Sensitivity studies of the passive emergency feedwater system were also conducted to investigate the response of the primary loop and the passive emergency feedwater system on the main parameters of the passive emergency feedwater system. The passive emergency feedwater system could supply water to the SG shell side from the EMT successfully. The calculation results showed that the passive emergency feedwater system could take away the decay heat from the primary loop effectively for air cooling condition, and that the single-phase and two-phase natural circulations were established in the primary loop and passive emergency feedwater system loop, respectively. (author)

  18. A study on an efficient prediction of welding deformation for T-joint laser welding of sandwich panel PART I : Proposal of a heat source model

    Directory of Open Access Journals (Sweden)

    Jae Woong Kim

    2013-09-01

    Full Text Available The use of I-Core sandwich panel has increased in cruise ship deck structure since it can provide similar bending strength with conventional stiffened plate while keeping lighter weight and lower web height. However, due to its thin plate thickness, i.e. about 4~6 mm at most, it is assembled by high power CO2 laser welding to minimize the welding deformation. This research proposes a volumetric heat source model for T-joint of the I-Core sandwich panel and a method to use shell element model for a thermal elasto-plastic analysis to predict welding deformation. This paper, Part I, focuses on the heat source model. A circular cone type heat source model is newly suggested in heat transfer analysis to realize similar melting zone with that observed in experiment. An additional suggestion is made to consider negative defocus, which is commonly applied in T-joint laser welding since it can provide deeper penetration than zero defocus. The proposed heat source is also verified through 3D thermal elasto-plastic analysis to compare welding deformation with experimental results. A parametric study for different welding speeds, defocus values, and welding powers is performed to investigate the effect on the melting zone and welding deformation. In Part II, focuses on the proposed method to employ shell element model to predict welding deformation in thermal elasto-plastic analysis instead of solid element model.

  19. Solar Process Heat Basics | NREL

    Science.gov (United States)

    Process Heat Basics Solar Process Heat Basics Commercial and industrial buildings may use the same solar technologies-photovoltaics, passive heating, daylighting, and water heating-that are used for residential buildings. These nonresidential buildings can also use solar energy technologies that would be

  20. Passive safety systems for integral reactors

    International Nuclear Information System (INIS)

    Kuul, V.S.; Samoilov, O.B.

    1996-01-01

    In this paper, a wide range of passive safety systems intended for use on integral reactors is considered. The operation of these systems relies on natural processes and does not require external power supplies. Using these systems, there is the possibility of preventing serious consequences for all classes of accidents including reactivity, loss-of-coolant and loss of heat sink as well as severe accidents. Enhancement of safety system reliability has been achieved through the use of self-actuating devices, capable of providing passive initiation of protective and isolation systems, which respond immediately to variations in the physical parameters of the fluid in the reactor or in a guard vessel. For beyond design base accidents accompanied by complete loss of heat removal capability, autonomous self-actuated ERHR trains have been proposed. These trains are completely independent of the secondary loops and need no action to isolate them from the steam turbine plant. Passive safety principles have been consistently implemented in AST-500, ATETS-200 and VPBER 600 which are new generation NPPs developed by OKBM. Their main characteristic is enhanced stability over a wide range of internal and external emergency initiators. (author). 10 figs

  1. Passive safety systems for integral reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kuul, V S; Samoilov, O B [OKB Mechanical Engineering (Russian Federation)

    1996-12-01

    In this paper, a wide range of passive safety systems intended for use on integral reactors is considered. The operation of these systems relies on natural processes and does not require external power supplies. Using these systems, there is the possibility of preventing serious consequences for all classes of accidents including reactivity, loss-of-coolant and loss of heat sink as well as severe accidents. Enhancement of safety system reliability has been achieved through the use of self-actuating devices, capable of providing passive initiation of protective and isolation systems, which respond immediately to variations in the physical parameters of the fluid in the reactor or in a guard vessel. For beyond design base accidents accompanied by complete loss of heat removal capability, autonomous self-actuated ERHR trains have been proposed. These trains are completely independent of the secondary loops and need no action to isolate them from the steam turbine plant. Passive safety principles have been consistently implemented in AST-500, ATETS-200 and VPBER 600 which are new generation NPPs developed by OKBM. Their main characteristic is enhanced stability over a wide range of internal and external emergency initiators. (author). 10 figs.

  2. Approaches to passive safety in advanced thermal reactors

    International Nuclear Information System (INIS)

    Moses, D.L.

    1986-01-01

    Since 1980, there has been a proliferation of thermal reactor designs which incorporate passive safety features. The evolution of this trend is briefly traced, and the nature of various passive safety features is discussed with regard to how they have been incorporated into evolving design concepts. The key aspects of the passive safety features include reduced core power density, enhanced passive heat sinks, inherent assured shutdown mechanisms, elimination/minimization of potential leak paths from the primary coolant systems, enhanced robustness of fuel elements and improved coolant chemistry and component materials. An increased reliance on purely passive safety features typically translates into larger reactor structures at reduced power ratings. Proponents of the most innovative concepts seek to offset the increased costs by simplifying licensing requirements and reducing construction time

  3. Design of a natural draft air-cooled condenser and its heat transfer characteristics in the passive residual heat removal system for 10 MW molten salt reactor experiment

    International Nuclear Information System (INIS)

    Zhao, Hangbin; Yan, Changqi; Sun, Licheng; Zhao, Kaibin; Fa, Dan

    2015-01-01

    As one of the Generation IV reactors, Molten Salt Reactor (MSR) has its superiorities in satisfying the requirements on safety. In order to improve its inherent safety, a concept of passive residual heat removal system (PRHRS) for the 10 MW Molten Salt Reactor Experiment (MSRE) was put forward, which mainly consisted of a fuel drain tank, a feed water tank and a natural draft air-cooled condenser (NDACC). Besides, several valves and pipes are also included in the PRHRS. A NDACC for the PRHRS was preliminarily designed in this paper, which contained a finned tube bundle and a chimney. The tube bundle was installed at the bottom of the chimney for increasing the velocity of the air across the bundle. The heat transfer characteristics of the NDACC were investigated by developing a model of the PRHRS using C++ code. The effects of the environmental temperature, finned tube number and chimney height on heat removal capacity of the NDACC were analyzed. The results show that it has sufficient heat removal capacity to meet the requirements of the residual heat removal for MSRE. The effects of these three factors are obvious. With the decay heat reducing, the heat dissipation power declines after a short-time rise in the beginning. The operation of the NDACC is completely automatic without the need of any external power, resulting in a high safety and reliability of the reactor, especially once the accident of power lost occurs to the power plant. - Highlights: • A model to study the heat transfer characteristics of the NDACC was developed. • The NDACC had sufficient heat removal capacity to remove the decay heat of MSRE. • NDACC heat dissipation power depends on outside temperature and condenser geometry. • As time grown, the effects of outside temperature and condenser geometry diminish. • The NDACC could automatically adjust its heat removal capacity

  4. Studies on the characteristics of the separated heat pipe system with non-condensible gas for the use of the passive decay heat removal in reactor systems

    International Nuclear Information System (INIS)

    Hayashi, Takao; Ishi, Takayuki; Hayakawa, Hitoshi; Ohashi, Kazutaka

    1997-01-01

    Experiments on the separated heat pipe system of variable conductance type, which enclose non-condensible gas, have been carried out with intention of applying such system to passive decay heat removal of the modular reactors such as HTR plant. Basic experiments have been carried out on the experimental apparatus consisting of evaporator, vapor transfer tube, condenser tube and return tube which returns the condensed liquid back to the evaporator. Water and methanol were examined as the working fluids and nitrogen gas was enclosed as the non-condensible gas. The behaviors of the system were examined for the parametric changes of the heat input under the various pressures of nitrogen gas initially enclosed, including the case without enclosing N 2 gas for the comparison. The results of the experiments shows very clear features of self control characteristics. The self control mechanism was made clear, that is, in such system in which the condensing area in the condenser expands automatically in accordance with the increase of the heat input to keep the system temperature nearly constant. The working temperature of the system are clearly dependent on the pressure of the non-condensable gas initially enclosed, with higher system working temperature with higher initial gas pressure enclosed. The analyses were done on water and methanol as the working fluids, which show very good agreement with the experimental results. A lot of attractive applications are expected including the self switching feature with minimum heat loss during normal operation with maintaining the sufficient heat removal at accidents. (author)

  5. Passive houses in Norway

    Energy Technology Data Exchange (ETDEWEB)

    Halse, Andreas

    2008-12-15

    The paper analyzes the introduction of passive houses in the Norwegian house market. Passive houses are houses with extremely low levels of energy consumption for heating, and have not yet been built in Norway, but have started to enter the market in Germany and some other countries. The construction sector is analyzed as a sectoral innovation system. The different elements of the innovation system are studied. This includes government agencies, producers, consumers, finance and education. The analysis shows that passive and low-energy houses are on the verge of market breakthrough. This can partly be explained by economic calculations, and partly by processes of learning and change in the institutional set-up of the sector. The construction sector is a sector characterized by low innovative intensity and little interaction between different agents. Those working to promote passive houses have to some extent managed to cope with these challenges. This has happened by breaking away from the traditional focus of Norwegian energy efficiency policies on technology and the economically rational agents, by instead focusing on knowledge and institutional change at the level of the producers. (Author)

  6. Concept Design of a Gravity Core Cooling Tank as a Passive Residual Heat Removal System for a Research Reactor

    International Nuclear Information System (INIS)

    Lee, Kwonyeong; Chi, Daeyoung; Kim, Seong Hoon; Seo, Kyoungwoo; Yoon, Juhyeon

    2014-01-01

    A core downward flow is considered to use a plate type fuel because it is benefit to install the fuel in the core. If a flow inversion from a downward to upward flow in the core by a natural circulation is introduced within a high heat flux region of residual heat, the fuel fails instantly due to zero flow. Therefore, the core downward flow should be sufficiently maintained until the residual heat is in a low heat flux region. In a small power research reactor, inertia generated by a flywheel of the PCP can maintain a downward flow shortly and resolve the problem of a flow inversion. However, a high power research reactor more than 10 MW should have an additional method to have a longer downward flow until a low heat flux. Usually, other research reactors have selected an active residual heat removal system as a safety class. But, an active safety system is difficult to design and expensive to construct. A Gravity Core Cooling Tank (GCCT) beside the reactor pool with a Residual Heat Removal Pipe connecting two pools was developed and designed preliminarily as a passive residual heat removal system for an open-pool type research reactor. It is very simple to design and cheap to construct. Additionally, a non-safety, but active residual heat removal system is applied with the GCCT. It is a Pool Water Cooling and Purification System. It can improve the usability of the research reactor by removing the thermal waves, and purify the reactor pool, the Primary Cooling System, and the GCCT. Moreover, it can reduce the pool top radiation level

  7. Passive Solar Heating Residences.

    Science.gov (United States)

    1979-07-01

    sunshine is the percentage of time during the average year that the sun is bright enough to cast a shadow Pcross a surface, divided by the number of hours...The Markle House in Vermont has 1,100 square feet of living area with a heat loss cf 17,500 BTU/hr. Particular attention was paid to reducing the...Determ.ine enierg;y savings of fossil fuel and electrical poweCr. 2. Determi.:ne the ftriction of the building’s hot)’ waiter , heting and/ur cooling load

  8. Thermal Performance and Operation Limit of Heat Pipe Containing Neutron Absorber

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Mo; Jeong, Yeong Shin; Kim, In Guk; Bang, In Choel [UNIST, Ulsan (Korea, Republic of)

    2015-05-15

    Recently, passive safety systems are under development to ensure the core cooling in accidents involving impossible depressurization such as station blackout (SBO). Hydraulic control rod drive mechanisms, passive auxiliary feedwater system (PAFS), Passive autocatalystic recombiner (PAR), and so on are types of passive safety systems to enhance the safety of nuclear power plants. Heat pipe is used in various engineering fields due to its advantages in terms of easy fabrication, high heat transfer rate, and passive heat transfer. Also, the various concepts associated with safety system and heat transfer using the heat pipe were developed in nuclear engineering field.. Thus, our group suggested the hybrid control rod which combines the functions of existing control rod and heat pipe. If there is significant temperature difference between active core and condenser, the hybrid control rod can shutdown the nuclear fission reaction and remove the decay heat from the core to ultimate heat sink. The unique characteristic of the hybrid control rod is the presence of neutron absorber inside the heat pipe. Many previous researchers studied the effect of parameters on the thermal performance of heat pipe. However, the effect of neutron absorber on the thermal performance of heat pipe has not been investigated. Thus, the annular heat pipe which contains B{sub 4}C pellet in the normal heat pipe was prepared and the thermal performance of the annular heat pipe was studied in this study. Hybrid control rod concept was developed as a passive safety system of nuclear power plant to ensure the safety of the reactor at accident condition. The hybrid control rod must contain the neutron absorber for the function as a control rod. So, the effect of neutron absorber on the thermal performance of heat pipe was experimentally investigated in this study. Temperature distributions at evaporator section of annular heat pipe were lower than normal heat pipe due to the larger volume occupied by

  9. Climate-Specific Passive Building Standards

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Graham S. [Passive House Inst., Westford, MA (United States); Klingenberg, Katrin [Passive House Inst., Westford, MA (United States)

    2015-07-01

    Passive design principles (super insulation, airtight envelopes, elimination of thermal bridges, etc.) - pioneered in North America in the 70s and 80s and refined in Europe in the 90s have proven to be universally effective to significantly reduce heating and cooling loads. However, a single, rigid performance metric developed in Germany has led to limited uptake of passive building principles in many regions of the United States. It has also, in many cases, promoted some design decisions that had negative effects on economic feasibility and thermal comfort. This study's main objective is to validate (in a theoretical sense) verifiable, climate-specific passive standards and space conditioning criteria that retain ambitious, environmentally-necessary energy reduction targets and are economically feasible, such standards provide designers an ambitious but achievable performance target on the path to zero.

  10. Economical evaluation of damaged vacuum insulation panels in buildings

    Science.gov (United States)

    Kim, Y. M.; Lee, H. Y.; Choi, G. S.; Kang, J. S.

    2015-12-01

    In Korea, thermal insulation standard of buildings have been tightened annually to satisfy the passive house standard from the year 2009. The current domestic policies about disseminating green buildings are progressively conducted. All buildings should be the zero energy building in the year 2025, obligatorily. The method is applied to one of the key technologies for high-performance insulation for zero energy building. The vacuum insulation panel is an excellent high performance insulation. But thermal performance of damaged vacuum insulation panels is reduced significantly. In this paper, the thermal performance of damaged vacuum insulation panels was compared and analyzed. The measurement result of thermal performance depends on the core material type. The insulation of building envelope is usually selected by economic feasibility. To evaluate the economic feasibility of VIPs, the operation cost was analyzed by simulation according to the types and damaged ratio of VIPs

  11. Thermoelectric Exhaust Heat Recovery with Heat Pipe-Based Thermal Control

    Science.gov (United States)

    Brito, F. P.; Martins, Jorge; Hançer, Esra; Antunes, Nuno; Gonçalves, L. M.

    2015-06-01

    Heat pipe (HP)-based heat exchangers can be used for very low resistance heat transfer between a hot and a cold source. Their operating temperature depends solely on the boiling point of their working fluid, so it is possible to control the heat transfer temperature if the pressure of the HP can be adjusted. This is the case of the variable conductance HPs (VCHP). This solution makes VCHPs ideal for the passive control of thermoelectric generator (TEG) temperature levels. The present work assesses, both theoretically and experimentally, the merit of the aforementioned approach. A thermal and electrical model of a TEG with VCHP assist is proposed. Experimental results obtained with a proof of concept prototype attached to a small single-cylinder engine are presented and used to validate the model. It was found that the HP heat exchanger indeed enables the TEG to operate at a constant, optimal temperature in a passive and safe way, and with a minimal overall thermal resistance, under part load, it effectively reduces the active module area without deprecating the temperature level of the active modules.

  12. Development and evaluation of aerogel-filled BMI sandwich panels for thermal barrier applications

    Directory of Open Access Journals (Sweden)

    A. Dineshkumar

    2016-07-01

    Full Text Available This study details a fabrication methodology envisaged to manufacture Glass/BMI honeycomb core aerogel-filled sandwich panels. Silica aerogel granules are used as core fillers to provide thermal insulation properties with little weight increase. Experimental heat transfer studies are conducted on these panels to study the temperature distribution between their two surfaces. Numerical studies are also carried out to validate the results. Despite exhibiting good thermal shielding capabilities, the Glass/BMI sandwich panels are found to oxidise at 180 ºC if exposed directly to heat. In order to increase the temperature bearing capacity and the operating temperature range for these panels, a way of coating them from outside with high temperature spray paint was tried. With a silicone-based coating, the temperature sustainability of these sandwich panels is found to increase to 350 ºC. This proved the effectiveness of the formed manufacturing process, selected high temperature coating, the coating method as well as the envisaged sandwich panel concept.

  13. Impact of Passive Safety on FHR Instrumentation Systems Design and Classification

    International Nuclear Information System (INIS)

    Holcomb, David Eugene

    2015-01-01

    Fluoride salt-cooled high-temperature reactors (FHRs) will rely more extensively on passive safety than earlier reactor classes. 10CFR50 Appendix A, General Design Criteria for Nuclear Power Plants, establishes minimum design requirements to provide reasonable assurance of adequate safety. 10CFR50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors, provides guidance on how the safety significance of systems, structures, and components (SSCs) should be reflected in their regulatory treatment. The Nuclear Energy Institute (NEI) has provided 10 CFR 50.69 SSC Categorization Guideline (NEI-00-04) that factors in probabilistic risk assessment (PRA) model insights, as well as deterministic insights, through an integrated decision-making panel. Employing the PRA to inform deterministic requirements enables an appropriately balanced, technically sound categorization to be established. No FHR currently has an adequate PRA or set of design basis accidents to enable establishing the safety classification of its SSCs. While all SSCs used to comply with the general design criteria (GDCs) will be safety related, the intent is to limit the instrumentation risk significance through effective design and reliance on inherent passive safety characteristics. For example, FHRs have no safety-significant temperature threshold phenomena, thus enabling the primary and reserve reactivity control systems required by GDC 26 to be passively, thermally triggered at temperatures well below those for which core or primary coolant boundary damage would occur. Moreover, the passive thermal triggering of the primary and reserve shutdown systems may relegate the control rod drive motors to the control system, substantially decreasing the amount of safety-significant wiring needed. Similarly, FHR decay heat removal systems are intended to be running continuously to minimize the amount of safety-significant instrumentation needed to initiate

  14. Energy savings solutions: passive solar design in Iranian cold climate

    Energy Technology Data Exchange (ETDEWEB)

    Nassehzadeh Tabriz, Shahram [Department of Architecture, Miyaneh Branch, Islamic Azad University (Iran, Islamic Republic of)], email: sh_nassehzadeh@m-iau.ac.ir; Mahdavi Tabatabaei Fard, Fariborz [SABAT TARH CO. (Iran, Islamic Republic of)], email: sabat_arc@yahoo.com; Aliyev, Fagan [International Eco-energy Academy (Azerbaijan)], email: ie_academy@yahoo.com

    2011-07-01

    In recent years, there has been a significant increase in the cost of fuel gas, fuel oil and electricity and much thought has been given to the use of solar energy. Living in a solar heated house gives peace of mind and body and it makes good sense in mountainous regions. Severe winters in such regions make more energy for standard living activities in buildings necessary. This paper discusses passive solar building design as an energy saving solution. In this type of design, windows, walls and floors act as storage and distribution devices for solar energy in winter and deflect solar heat in summer. Passive solar design techniques influence the choice of building site, design and materials within the general framework of enriching the quality of life of the inhabitants. As a result, natural resources are saved and the environment is conserved for future generations. In conclusion, it is seen that passive design keeps a home cool and comfortable in summer and warm and cozy in winter with minimal heating and cooling requirements.

  15. Experimental and numerical study of heat transfer across insulation wall of a refrigerated integral panel van

    International Nuclear Information System (INIS)

    Glouannec, Patrick; Michel, Benoit; Delamarre, Guillaume; Grohens, Yves

    2014-01-01

    This paper presents an experimental and numerical design study of an insulation wall for refrigerated vans. The thermophysical properties of the insulating multilayer panel, the external environment impact (solar irradiation, temperature, etc.) and durability are taken into account. Different tools are used to characterize the thermal performances of the insulation walls and the thermal properties of the insulation materials are measured. In addition, an experiment at the wall scale is carried out and a 2D FEM model of heat and mass transfer within the wall is formulated. Three configurations are studied with this design approach. Multilayer insulation walls containing reflective multi-foil insulation, aerogel and phase change materials (PCM) are tested. Promising results are obtained with these materials, especially the reduction of peak heat transfer and energy consumption during the daytime period. Furthermore, the major influence of solar irradiation is highlighted as it can increase the peak heat transfer crossing the insulation wall by up to 43%. Nevertheless, we showed that the use of reflective multi-foil insulation and aerogel layers allowed decreasing this impact by 27%. - Highlights: • A design study of an insulation wall for a refrigerated van is carried out. • Experimental and numerical studies of multilayer insulation walls are performed. • The major influence of solar irradiation is highlighted. • New insulation materials (reflective multi-foil, aerogel and PCM) are tested

  16. Effect of excimer laser annealing on a-InGaZnO thin-film transistors passivated by solution-processed hybrid passivation layers

    International Nuclear Information System (INIS)

    Bermundo, Juan Paolo; Ishikawa, Yasuaki; Fujii, Mami N; Uraoka, Yukiharu; Nonaka, Toshiaki; Ishihara, Ryoichi; Ikenoue, Hiroshi

    2016-01-01

    We demonstrate the use of excimer laser annealing (ELA) as a low temperature annealing alternative to anneal amorphous InGaZnO (a-IGZO) thin-film transistors (TFTs) passivated by a solution-processed hybrid passivation layer. Usually, a-IGZO is annealed using thermal annealing at high temperatures of up to 400 °C. As an alternative to high temperature thermal annealing, two types of ELA, XeCl (308 nm) and KrF (248 nm) ELA, are introduced. Both ELA types enhanced the electrical characteristics of a-IGZO TFTs leading to a mobility improvement of ∼13 cm 2 V −1 s −1 and small threshold voltage which varied from ∼0–3 V. Furthermore, two-dimensional heat simulation using COMSOL Multiphysics was used to identify possible degradation sites, analyse laser heat localization, and confirm that the substrate temperature is below 50 °C. The two-dimensional heat simulation showed that the substrate temperature remained at very low temperatures, less than 30 °C, during ELA. This implies that any flexible material can be used as the substrate. These results demonstrate the large potential of ELA as a low temperature annealing alternative for already-passivated a-IGZO TFTs. (paper)

  17. Increasing the efficiency of solar thermal panels

    Science.gov (United States)

    Dobrnjac, M.; Latinović, T.; Dobrnjac, S.; Živković, P.

    2016-08-01

    The popularity of solar heating systems is increasing for several reasons. These systems are reliable, adaptable and pollution-free, because the renewable solar energy is used. There are many variants of solar systems in the market mainly constructed with copper pipes and absorbers with different quality of absorption surface. Taking into account the advantages and disadvantages of existing solutions, in order to increase efficiency and improve the design of solar panel, the innovative solution has been done. This new solar panel presents connection of an attractive design and the use of constructive appropriate materials with special geometric shapes. Hydraulic and thermotechnical tests that have been performed on this panel showed high hydraulic and structural stability. Further development of the solar panel will be done in the future in order to improve some noticed disadvantages.

  18. Passive containment cooling system performance in the simplified boiling water reactor

    International Nuclear Information System (INIS)

    Shiralkar, B.S.; Gamble, R.E.; Yadigaroglu, G.

    1997-01-01

    The Simplified Boiling Water Reactor (SBWR) incorporates a passive system for decay heat removal from the containment in the event of a postulated Loss-of-Coolant Accident (LOCA). Decay heat is removed by condensation of the steam discharged from the reactor pressure vessel (RPV) in three condensers which comprise the Passive Containment Cooling System (PCCS). These condensers are designed to carry the heat load while transporting a mixture of steam and noncondensible gas (primarily nitrogen) from the drywell to the suppression chamber. This paper describes the expected LOCA response of the SBWR with respect to the PCCS performance, based on analysis and test results. The results confirm that the PCCS has excess capacity for decay heat removal and that overall system performance is very robust. 12 refs., 8 figs

  19. Thermal and Mechanical Buckling and Postbuckling Responses of Selected Curved Composite Panels

    Science.gov (United States)

    Breivik, Nicole L.; Hyer, Michael W.; Starnes, James H., Jr.

    1998-01-01

    The results of an experimental and numerical study of the buckling and postbuckling responses of selected unstiffened curved composite panels subjected to mechanical end shortening and a uniform temperature increase are presented. The uniform temperature increase induces thermal stresses in the panel when the axial displacement is constrained. An apparatus for testing curved panels at elevated temperature is described, numerical results generated by using a geometrically nonlinear finite element analysis code are presented. Several analytical modeling refinements that provide more accurate representation of the actual experimental conditions, and the relative contribution of each refinement, are discussed. Experimental results and numerical predictions are presented and compared for three loading conditions including mechanical end shortening alone, heating the panels to 250 F followed by mechanical end shortening, and heating the panels to 400 F. Changes in the coefficients of thermal expansion were observed as temperature was increased above 330 F. The effects of these changes on the experimental results are discussed for temperatures up to 400 F.

  20. Engineered safeguards and passive safety features (safety analysis detailed report no. 6)

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-15

    The Safety-Analysis Summary lists the reactor's safety aspects for passive and active prevention of severe accidents and mitigation of accident consequences, i.e., intrinsic and passive protections of the plant; intrinsic and passive protections of the core; inherent decay-heat removal systems; rapid-shutdown systems; four physical containment barriers. This report goes into further details regarding some of this aspects.

  1. Indoor environment in Swedish passive houses

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Langer, Sarka; Bloom, Erica Bloom

    2014-01-01

    The purpose of this study was to evaluate the indoor air quality (IAQ) in newly built low energy houses. Measurements were performed in 22 passive houses and 21 conventional buildings during 2012-2013 and 2013-2014 heating seasons. The measured parameters were temperature, relative humidity......, concentration of CO2, NO2, formaldehyde, volatile organic compounds, and live microbiological flora. Air exchange rates (AER) were determined from the concentration-time profiles of CO2. The median AER was slightly higher in the passive houses than in conventional buildings (0.66 h-1 vs. 0.60 h-1). The median...... concentrations in passive houses and conventional buildings were 9.7 and 11 μg/m3, respectively, for NO2, 12 and 16 μg/m3 for formaldehyde, and 230 and 145 μg/m3 for TVOC. The indoor microbiological flora did not differ, with a few exceptions, from outdoors. The IAQ in the passive buildings was judged...

  2. Passive cooling system for nuclear reactor containment structure

    Science.gov (United States)

    Gou, Perng-Fei; Wade, Gentry E.

    1989-01-01

    A passive cooling system for the contaminant structure of a nuclear reactor plant providing protection against overpressure within the containment attributable to inadvertent leakage or rupture of the system components. The cooling system utilizes natural convection for transferring heat imbalances and enables the discharge of irradiation free thermal energy to the atmosphere for heat disposal from the system.

  3. System code improvements for modelling passive safety systems and their validation

    Energy Technology Data Exchange (ETDEWEB)

    Buchholz, Sebastian; Cron, Daniel von der; Schaffrath, Andreas [Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) gGmbH, Garching (Germany)

    2016-11-15

    GRS has been developing the system code ATHLET over many years. Because ATHLET, among other codes, is widely used in nuclear licensing and supervisory procedures, it has to represent the current state of science and technology. New reactor concepts such as Generation III+ and IV reactors and SMR are using passive safety systems intensively. The simulation of passive safety systems with the GRS system code ATHLET is still a big challenge, because of non-defined operation points and self-setting operation conditions. Additionally, the driving forces of passive safety systems are smaller and uncertainties of parameters have a larger impact than for active systems. This paper addresses the code validation and qualification work of ATHLET on the example of slightly inclined horizontal heat exchangers, which are e. g. used as emergency condensers (e. g. in the KERENA and the CAREM) or as heat exchanger in the passive auxiliary feed water systems (PAFS) of the APR+.

  4. Evaluation of photovoltaic panel temperature in realistic scenarios

    International Nuclear Information System (INIS)

    Du, Yanping; Fell, Christopher J.; Duck, Benjamin; Chen, Dong; Liffman, Kurt; Zhang, Yinan; Gu, Min; Zhu, Yonggang

    2016-01-01

    Highlights: • The developed realistic model captures more reasonably the thermal response and hysteresis effects. • The predicted panel temperature is as high as 60 °C under a solar irradiance of 1000 W/m"2 in no-wind weather. • In realistic scenarios, the thermal response normally takes 50–250 s. • The actual heating effect may cause a photoelectric efficiency drop of 2.9–9.0%. - Abstract: Photovoltaic (PV) panel temperature was evaluated by developing theoretical models that are feasible to be used in realistic scenarios. Effects of solar irradiance, wind speed and ambient temperature on the PV panel temperature were studied. The parametric study shows significant influence of solar irradiance and wind speed on the PV panel temperature. With an increase of ambient temperature, the temperature rise of solar cells is reduced. The characteristics of panel temperature in realistic scenarios were analyzed. In steady weather conditions, the thermal response time of a solar cell with a Si thickness of 100–500 μm is around 50–250 s. While in realistic scenarios, the panel temperature variation in a day is different from that in steady weather conditions due to the effect of thermal hysteresis. The heating effect on the photovoltaic efficiency was assessed based on real-time temperature measurement of solar cells in realistic weather conditions. For solar cells with a temperature coefficient in the range of −0.21%∼−0.50%, the current field tests indicated an approximate efficiency loss between 2.9% and 9.0%.

  5. Protocol Monitoring Passive Solar Energy. Background document

    International Nuclear Information System (INIS)

    Van den Ham, E.R.

    1998-01-01

    A method has been developed by means of which the contribution of passive solar energy to the Dutch energy balance can be quantified univocally. The monitoring will be directed at the absolute amount of used solar energy, the relative contribution of passive solar energy to the energy demand in the Netherlands, and the average efficiency of passive solar energy systems. Based on a model of the total building stock the quantities to be monitored can be determined. The most important parameters in the model are: the window surface per orientation, the average U-value (heat transfer coefficient) of windows, the average ZTA-value (incoming solar radiation factor) of windows, and the presence of sun lounges and atriums

  6. Evaluation of a Design Concept for the Combined Air-water Passive Cooling PAFS+

    International Nuclear Information System (INIS)

    Bae, Sung Won; Kwon, Taesoon

    2014-01-01

    The APR+ system provides the Passive Auxiliary Feed-water System (PAFS) for the passive cooling capability. However, the current design requirement for working time for the PAFS is about 8 hours only. Thus, current working time of PAFS can not meet the required 72 hours cooling capability for the long term SBO situation. To meet the 72 hours cooling, the pool capacity should be almost 3∼4 times larger than that of current water cooling tank. In order to continue the PAFS operation for 72 hours, a new passive air-water combined cooling system is proposed. This paper provides the feasibility study on the combined passive air-water cooling system. Figure 1 and 2 show the conceptual difference of the PAFS and combined passive air-water cooling system, respectively. Simple performance evaluation of the passive air cooling heat exchanger has been conducted by the MARS calculation. For the postulated FLB scenario, 4800 heat exchanger tubes and 5 m/s air velocity are not sufficient to sustain the PCCT pool level for 72 hour cooling. Further works on the system design and performance enhancing plan are required to fulfill the 72 hours long term passive cooling

  7. Absorptive coating for aluminum solar panels

    Science.gov (United States)

    Desmet, D.; Jason, A.; Parr, A.

    1979-01-01

    Method for coating forming coating of copper oxide from copper component of sheet aluminum/copper alloy provides strong durable solar heat collector panels. Copper oxide coating has solar absorption characteristics similar to black chrome and is much simpler and less costly to produce.

  8. ESBWR related passive decay heat removal tests in PANDA

    International Nuclear Information System (INIS)

    Huggenberger, M.; Aubert, C.; Bandurski, T.; Dreier, J.; Fischer, O.; Strassberger, H.J.; Yadigaroglu, G.

    1999-01-01

    A number of test series to investigate passive safety systems for the next generation of Light Water Reactors have been performed in the PANDA multi-purpose facility at the Paul Scherrer Institut (PSI). The large scale thermal-hydraulic test facility allows to investigate LWR containment phenomena and system behaviour. PANDA was first used to examine the Passive Containment Cooling System (PCCS) for the Simplified Boiling Water Reactor (SBWR). In 1996 new test series were initiated; all related to projects of the EC Fourth Framework Programme on Nuclear Fission Safety. One of these projects (TEPSS) is focused on the European Simplified Boiling Water Reactor (ESBWR). The ESBWR containment features and PCCS long-term post LOCA response were investigated in PANDA. The PCCS start-up was demonstrated, the effect of nitrogen hidden somewhere in the drywell and released later in the transient was simulated and the effect of light gases (helium) on the PCCS performance was investigated. Finally, the influence of low PCC pool levels on PCCS and containment performance was examined. The main findings were that the PCCS works as intended and shows generally a favorable and robust long-term post LOCA behaviour. The system starts working even under extreme conditions and trapped air released from the drywell later in the transient does only temporarily reduce the PCCS performance. The new PANDA test series provided an extensive data base which will contribute to further improve containment design of passive plants and allow for system code assessment in a wide parameter range. (author)

  9. An innovative pool with a passive heat removal system

    International Nuclear Information System (INIS)

    Vitale Di Maio, Damiano; Naviglio, Antonio; Giannetti, Fabio; Manni, Fabio

    2012-01-01

    Heat removal systems are of primary importance in several industrial processes. As heat sink, a water pool or atmospheric air may be selected. The first solution takes advantage of high heat transfer coefficient with water but it requires active systems to maintain a constant water level; the second solution takes benefit from the unlimited heat removal capacity by air, but it requires a larger heat exchanger to compensate the lower heat transfer coefficient. In NPPs (nuclear power plants) during a nuclear reactor shutdown, as well as in some chemical plants to control runaway reactions, it is possible to use an innovative heat sink that joins the advantages of the two previous solutions. This solution is based on a special heat exchanger submerged in a water pool designed so that when heat removal is requested, active systems are not required to maintain the water level; due to the special design, when the pool is empty, atmospheric air becomes the only heat sink. The special heat exchanger design allows to have a heat exchanger without being oversized and to have a system able to operate for unlimited period without external interventions. This innovative system provides an economic advantage as well as enhanced safety features.

  10. Fracture Mechanics Analyses of the Slip-Side Joggle Regions of Wing-Leading Edge Panels

    Science.gov (United States)

    Raju, Ivatury S.; Knight, Norman F., Jr.; Song, Kyongchan; Phillips, Dawn R.

    2010-01-01

    The Space Shuttle Orbiter wing comprises of 22 leading edge panels on each side of the wing. These panels are part of the thermal protection system that protects the Orbiter wings from extreme heating that take place on the reentry in to the earth atmosphere. On some panels that experience extreme heating, liberation of silicon carbon (SiC) coating was observed on the slip side regions of the panels. Global structural and local fracture mechanics analyses were performed on these panels as a part of the root cause investigation of this coating liberation anomaly. The wing-leading-edge reinforced carbon-carbon (RCC) panels, Panel 9, T-seal 10, and Panel 10, are shown in Figure 1 and the progression of the stress analysis models is presented in Figure 2. The global structural analyses showed minimal interaction between adjacent panels and the T-seal that bridges the gap between the panels. A bounding uniform temperature is applied to a representative panel and the resulting stress distribution is examined. For this loading condition, the interlaminar normal stresses showed negligible variation in the chord direction and increased values in the vicinity of the slip-side joggle shoulder. As such, a representative span wise slice on the panel can be taken and the cross section can be analyzed using plane strain analysis.

  11. Numerical simulation of passive heat removal under severe core meltdown scenario in a sodium cooled fast reactor

    Energy Technology Data Exchange (ETDEWEB)

    David, Dijo K.; Mangarjuna Rao, P., E-mail: pmr@igcar.gov.in; Nashine, B.K.; Selvaraj, P.; Chellapandi, P.

    2015-09-15

    Highlights: • PAHR in SFR under large core relocation to in-vessel core catcher is numerically analyzed. • A 1-D thermal conduction model and a 2-D axisymmetric CFD model are developed for turbulent natural convection phenomenon. • The side pool (cold pool) was found out to be instrumental in storing heat and dissipating it to the heat sink. • Single tray type in-vessel core catcher is found to be thermally effective under one-fourth core relocation. - Abstract: A sequence of highly unlikely events leading to significant meltdown of the Sodium cooled Fast Reactor (SFR) core can cause the failure of reactor vessel if the molten fuel debris settles at the bottom of the reactor main vessel. To prevent this, pool type SFRs are usually provided with an in-vessel core catcher above the bottom wall of the main vessel. The core catcher should collect, retain and passively cool these debris by facilitating decay heat removal by natural convection. In the present work, the heat removal capability of the existing single tray core catcher design has been evaluated numerically by analyzing the transient development of natural convection loops inside SFR pool. A 1-D heat diffusion model and a simplified 2-D axi-symmetric CFD model are developed for the same. Maximum temperature of the core catcher plate evaluated for different core meltdown scenarios using these models showed that there is much higher heat removal potential for single tray in-vessel SFR core catcher compared to the design basis case of melting of 7 subassemblies under total instantaneous blockage of a subassembly. The study also revealed that the side pool of cold sodium plays a significant role in decay heat removal. The maximum debris bed temperature attained during the initial hours of PAHR does not depend much on when the Decay Heat Exchanger (DHX) gets operational, and it substantiates the inherent safety of the system. The present study paves the way for better understanding of the thermal

  12. Passive containment system for a nuclear reactor

    International Nuclear Information System (INIS)

    Kleimola, F.W.

    1976-01-01

    A containment system is described that provides complete protection entirely by passive means for the loss of coolant accident in a nuclear power plant and wherein all stored energy released in the coolant blowdown is contained and absorbed while the nuclear fuel is continuously maintained submerged in liquid. The primary containment vessel is restored to a high subatmospheric pressure within a few minutes after accident initiation and the decay heat is safely transferred to the environment while radiolytic hydrogen is contained by passive means

  13. A Simple Fully Passive Safety Option for SMART SBLOCA

    International Nuclear Information System (INIS)

    Lee, Won Jae

    2012-01-01

    SMART reactor, an integral pressurized water reactor (iPWR), is developed by KAERI and now under standard design licensing review. Integral reactor design of the SMART has small diameter penetrations below 2 inches at upper parts of reactor pressure vessel (RPV) and the core is located at very lower part. Amount of reactor coolant inventory is around 0.55tons/MWth during normal operations, which is seven times more than that of conventional PWRs. Such intrinsic safety features of the SMART can provide prolonged core cooling during a small-break loss-of-coolant accident (SBLOCA). As an engineered safety feature for SBLOCA, electrically two-train and mechanically four-train active safety injection (SI) systems are provided to refill the RPV, whose safety been proven through safety analysis and experiments. In addition, four-train passive residual heat removal systems (PRHRSs) are provided to remove core decay heat by natural circulation in the secondary side of steam generators during transient and accident conditions. After Fukushima disaster, a passive safety of nuclear power plants has become more emphasized than conventional active safety, even though there are still debates whether it can really insure the realistic safety. Passive safety is defined such that the core safety is ensured for 72 hours after accidents without any active safety systems and operator actions. In light of this, a simple fully passive safety option for SBLOCA is proposed: low-pressure safety injection tanks (SITs) and heat pipes submerged in the PRHRS emergency coolant tanks (ECTs). Post-LOCA long-term cooling after 72 hours is provided by sump recirculation using shutdown cooling system. Realistic analysis method using MARS3.1 is used to derive fully passive safety option, and then to screen design and operating parameters and to demonstrate the safety performance of SITs. SI line break is selected as a reference SBLOCA scenario

  14. Design and development of innovative passive valves for Nuclear Power Plant applications

    Energy Technology Data Exchange (ETDEWEB)

    Sapra, M.K., E-mail: sapramk@barc.gov.in; Kundu, S.; Pal, A.K.; Vijayan, P.K.; Vaze, K.K.; Sinha, R.K.

    2015-05-15

    Highlights: • Passive valves are self-acting valves requiring no external energy to function. • These valves have been developed for Advanced Heavy Water Reactor (AHWR) of India. • Passive valves are core components of passive safety systems of the reactor. • Accumulator Isolation Passive Valve (AIPV) has been developed and tested for ECSS. • AIPV provided passive isolation and flow regulation in ECCS of Integral Test Loop. - Abstract: The recent Fukushima accident has resulted in an increased need for passive safety systems in upcoming advanced reactors. In order to enhance the global contribution and acceptability of nuclear energy, proven evidence is required to show that it is not only green but also safe, in case of extreme natural events. To achieve and establish this fact, we need to design, demonstrate and incorporate reliable ‘passive safety systems’ in our advanced reactor designs. In Nuclear Power Plants (NPPs), the use of passive safety systems such as accumulators, condensing and evaporative heat exchangers and gravity driven cooling systems provide enhanced safety and reliability. In addition, they eliminate the huge costs associated with the installation, maintenance and operation of active safety systems that require multiple pumps with independent and redundant electric power supplies. As a result, passive safety systems are preferred for numerous advanced reactor concepts. In current NPPs, passive safety systems which are not participating in day to day operation, are kept isolated, and require a signal and external energy source to open the valve. It is proposed to replace these valves by passive components and devices such as self-acting valves, rupture disks, etc. Some of these innovative passive valves, which do not require external power, have been recently designed, developed and tested at rated conditions. These valves are proposed to be used for various passive safety systems of an upcoming Nuclear Power Plant being designed

  15. The Advantages of the Passive Construction of Office Buildings in the Jiu Valley

    Directory of Open Access Journals (Sweden)

    Andreea Cristina TATARU

    2016-06-01

    Full Text Available The concept of a 'passive House' has been introduced for the first time in Germany, subsequently being extended and at higher latitudes and different features climatic from those of Germany, in the south, west and south-west of Europe. In this paper we strive to study at the concept of 'passive house' in the Jiu Valley (latitude 45.63, and longitude 25.41 Using the Passive House Planning Package (PHPP software 2007 calculate the heating requirements for such a House, depending on the latitude and climate conditions in the locality. It will also analyze the constructive solutions for reduction of the amount of heat below the maximum allowed for a "passive house" (which is 15 kWh/m² per year. Also we will present you which are advantages of construction of this kind of building.

  16. Integrated solar-assisted heat pumps for water heating coupled to gas burners; control criteria for dynamic operation

    International Nuclear Information System (INIS)

    Scarpa, F.; Tagliafico, L.A.; Tagliafico, G.

    2011-01-01

    A direct expansion integrated solar-assisted heat pump (ISAHP) is compared to a traditional flat plate solar panel for low temperature (45 deg. C) water heating applications. The (simulated) comparison is accomplished assuming both the devices are energy supplemented with an auxiliary standard gas burner, to provide the typical heat duty of a four-member family. Literature dynamical models of the systems involved have been used to calculate the main performance figures in a context of actual climatic conditions and typical stochastic user demand. The paper highlights new heat pump control concepts, needed when maximum energy savings are the main goal of the apparatus for given user demand. Simulations confirm the high collector efficiency of the ISAHP when its panel/evaporator works at temperature close to the ambient one. The device, with respect to a flat plate solar water heater, shows a doubled performance, so that it can do the same task just using an unglazed panel with roughly half of the surface.

  17. The procurement and testing of the stainless steel in-vessel panels of the Wendelstein 7-X Stellarator

    International Nuclear Information System (INIS)

    Peacock, A.; Girlinger, A.; Vorkoeper, A.; Boscary, J.; Greuner, H.; Hurd, F.; Mendelevitch, B.; Pirsch, H.; Stadler, R.; Zangl, G.

    2011-01-01

    320 In-vessel water cooled stainless steel panels, poloidal closure plates and pumping gap panels, covering an area of approximately 100 m 2 , are used in Wendelstein7-X to protect the plasma vessel. The panels are manufactured at Deggendorf, Germany by MAN Diesel and Turbo SE. The panels consist of a laser welded sandwich of stainless steel plates together with a labyrinth of cooling channels and have a complicated geometry to fit the plasma vessel of Wendelstein 7-X. The hydraulic and mechanical stability requirements whilst maintaining the tight tolerances for the shape of the components are very demanding. The panels are designed to operate at up to an average heat load of 100 kW/m 2 and a maximum heat load of 200 kW/m 2 with a water velocity of approximately 2 m s -1 . High heat flux testing of an un-cooled panel at a time averaged load of 200 kW/m 2 for 10 s were successfully performed to support the start up phase of Wendelstein 7-X operation. Extensive testing both during manufacture and after delivery to IPP-Garching demonstrates the suitability of the delivered panels for their purpose.

  18. Advances in passive cooling design and performance analysis

    International Nuclear Information System (INIS)

    Woodcock, J.

    1994-01-01

    The Third International Conference on Containment Design and Operation continues the trend of rapidly extending the state of the art in containment methodology, joining other conferences, OECD-sponsored International Standard Problem exercises, and vendor licensing submittals. Methodology developed for use on plants with passive features is under increasing scrutiny for advanced designs, since the passive features are often the only deviation from existing operating base of the past 30 years of commercial nuclear power. This session, 'Containment Passive Safety Systems Design and Operation,' offers papers on a wide range of topics, with authors from six organizations from around the world, dealing with general passive containments, Westinghouse AP600, large (>1400 MWe) passive plants, and the AECL advanced CANDU reactor. This level and variety of participation underscores the high interest and accelerated methods development associated with advanced passive containment heat removal. The papers presented in this session demonstrate that significant contributions are being made to the advancement of technology necessary for building a new generation of safer, more economical nuclear plants. (author)

  19. Coupled analysis of passive safety injection and containment filtered venting for passive decay heat removal - 15140

    International Nuclear Information System (INIS)

    Kim, S.H.; Ham, J.H.; Jeong, Y.H.; Chang, S.H.

    2015-01-01

    Lots of interests for the safety of nuclear power plants have risen these days. The safety has to be continuously reviewed and enhanced in nuclear power plants currently operating as well as those designed and constructed in future. After the Fukushima accidents, many additional safety systems which can be applied to nuclear power plants in operation have been proposed. Those include alternating power source such as movable diesel generators and DC batteries in non-safety grade. Also, emergency preparedness for the prevention of a core damage accident was proposed to cope with the extended-SBO (station blackout) by using fire protection systems. In order to prevent the release of radioactive materials, safety systems for preserving the integrity of containment were proposed in two views of cooling and venting containment. Two approaches are effective for mitigating a severe accident. The design concept installing big water tanks besides containment at high level was proposed for various safety functions. One of the functions in the system is to inject the coolant from the elevated tank into a reactor vessel in the case of loss of coolant accident. When the pressure in reactor coolant system is sufficiently low, the coolant can be injected by gravity. If not, the depressurization in reactor vessel would be needed considering the containment pressure. Containment cooling in conventional pressurized water reactors is dependent on containment cooling pumps and sprays. Additional containment cooling systems cannot be simply and easily applied in the current nuclear power plants without major modifications. Therefore, for the operation of passive safety injection system, containment filtered venting system can be adopted for the depressurization of containment. In the design and operation of the passive safety injection system and the containment filtered venting system, main operating points related with open and close pressures in the filtered venting system were

  20. Some important issues in evaluating the availability of passive systems

    International Nuclear Information System (INIS)

    Kafka, P.; Kelemen, I.; Krzykacz, B.

    1993-01-01

    In some countries new reactor concepts based on a broader use of passive safety features are under development. The term 'passive' as used here refers to systems which rely heavily on natural heat transfer process such as natural circulation to perform their function rather than on decidedly 'active' components like pumps. The paper deals with important issues in evaluating the availability of passive systems, e.g. the assessment of the active components, the assessment of passive components and structures and the probabilistic assessment of the physical function of the natural processes. Based on an outlined assessment process for the entire system and on an exercised simulation process for the assessment of passive components e.g. pipes insights and important issues are presented. A follow-up study will refine and expand the concept to a full scope assessment procedure of passive systems. (author)

  1. Simulation and optimisation of a ground source heat pump with different ground heat exchanger configurations for a single-family residential house

    DEFF Research Database (Denmark)

    Pavlov, Georgi Krasimiroy; Olesen, Bjarne W.

    2012-01-01

    In the future there will be an increased demand for energy efficient cooling of residential buildings. Therefore it is essential to develop cooling concepts that are passive and/or using very little primary energy. A possible solution is a ground source heat pump combined with a low-temperature h....... For the studied geographical location, passive cooling by bypassing the heat pump and using only the ground heat exchanger can provide acceptable room temperatures.......In the future there will be an increased demand for energy efficient cooling of residential buildings. Therefore it is essential to develop cooling concepts that are passive and/or using very little primary energy. A possible solution is a ground source heat pump combined with a low......-temperature heating and high-temperature cooling system. The present work evaluates the performance in relation to thermal comfort and energy consumption of a GSHP with different GHE concepts. The different configurations are analyzed being part of the energy supply system of a low-energy residential house...

  2. Preliminary investigation on reliability assessment of passive safety system

    International Nuclear Information System (INIS)

    Huang Changfan; Kuang Bo

    2012-01-01

    The reliability evaluation of passive safety system plays an important part in probabilistic safety assessment (PSA) of nuclear power plant applying passive safety design, which depends quantitatively on reliabilities of passive safety system. According to the object of reliability assessment of passive safety system, relevant parameters are identified. Then passive system behavior during accident scenarios are studied. A practical example of this method is given for the case of reliability assessment of AP1000 passive heat removal system in loss of normal feedwater accident. Key and design parameters of PRHRS are identified and functional failure criteria are established. Parameter combinations acquired by Latin hyper~ cube sampling (LHS) in possible parametric ranges are input and calculations of uncertainty propagation through RELAP5/MOD3 code are carried out. Based on the calculations, sensitivity assessment on PRHRS functional criteria and reliability evaluation of the system are presented, which might provide further PSA with PRHR system reliability. (authors)

  3. Protocol Monitoring Passive Solar Energy

    International Nuclear Information System (INIS)

    Van den Ham, E.R.; Bosselaar, L.

    1998-01-01

    A method has been developed by means of which the contribution of passive solar energy to the Dutch energy balance can be quantified univocally. The contribution was 57 PJ in 1990 and also 57 PJ in 1995. The efficiency of passive solar energy systems increased from -31.5% to -28.1% in the period 1990-1995, mainly as a result of the use of extra insulating glazing. As a result of the reduction of energy consumption for heating in houses it is expected that the extra contribution of 2 PJ will not be realized in the year 2010. It is suggested that the method to determine the absolute contribution of passive solar energy to the energy demand of dwellings is to be included in the protocol monitoring renewable energy. For the method to be included in the energy statistics of Statistics Netherlands (CBS) it can be considered only to take into account the difference compared to 1990. 11 refs

  4. Fabrication and laboratory-based performance testing of a building-integrated photovoltaic-thermal roofing panel

    International Nuclear Information System (INIS)

    Chen, Fangliang; Yin, Huiming

    2016-01-01

    Highlights: • A BIPVT solar panel is designed and fabricated for energy efficient buildings. • A high-speed manufacture method is developed to produce the functionally graded materials. • Laboratory tests demonstrate BIPVT’s energy efficiency improvement and innovations. • The PV efficiency is enhanced ∼24% through temperature control of the panel by water flow. • The combined electric and thermal efficiency reaches >75% of solar irradiation. - Abstract: A building integrated photovoltaic-thermal (BIPVT) multifunctional roofing panel has been developed in this study to harvest solar energy in the form of PV electricity as well as heat energy through the collection of warm water. As a key component of the multifunctional building envelope, an aluminum/high-density polyethylene (HDPE) functionally graded material (FGM) panel embedded with aluminum water tubes has been fabricated through the vibration-sedimentation approach. The FGM layer gradually transits material phases from well-conductive side (with aluminum dominated) to another highly insulated side (with HDPE). The heat in the PV cells can be easily transferred into the conductive side of the FGM and then collected by the water flow in the embedded tubes. Therefore, the operational temperature of the PV cells can be significantly lowered down, which recovers the PV efficiency in hot weather. In this way, the developed BIPVT panel is able to efficiently harvest solar energy in the form of both PV electricity and heat. The performance of a prototype BIPVT panel has been evaluated in terms of its thermal efficiency via warm water collection and PV efficiency via the output electricity. The laboratory test results demonstrate that significant energy conversion efficiency improvement can be achieved for both electricity generation and heat collection by the presented BIPVT roofing system. Overall, the performance indicates a very promising prospective of the new BIPVT multifunctional roofing panel.

  5. Steady state flow evaluations for passive auxiliary feedwater system of APR

    International Nuclear Information System (INIS)

    Park, Jongha; Kim, Jaeyul; Seong, Hoje; Kang, Kyoungho

    2012-01-01

    This paper briefly introduces a methodology to evaluate steady state flow of APR+ Passive Auxiliary Feedwater System (PAFS). The PAFS is being developed as a safety grade passive system to completely replace the existing active Auxiliary Feedwater System (AFWS). Natural circulation cooling can be generally classified into the single-phase, two-phase, and boiling-condensation modes. The PAF is designed to be operated in a boiling-condensation natural circulation mode. The steady-state flow rate should be equal to the steady-state boiling/condensation rate determined by the steady-state energy and momentum balances in the PAFS. The determined steady-state flow rate can be used in the design optimization for the natural circulation loop of the PAFS through the steady-state momentum balance. Since the retarding force, which is to be balanced by the driving force in the natural circulation system design depends on the reliable evaluation of the success of a natural circulation system design depends on the reliable evaluation of the pressure loss coefficients. In PAFS, the core decay heat is released by natural circulation flow between the S G secondary side and the Passive Condensation Heat Exchanger (PCHX) that is immersed in the Passive Condensation Cooling Tank (PCCT). The PCCT is located on the top of Auxiliary building The driving force is determined by the difference between the S/G (heat Source) secondary water level and condensation liquid (heat sink) level. It will overcome retarding force at flowrate in the system, which is determined by vaporization and condensation of the steam which is generated at the S/G by the latent heat in system. In this study, the theoretical method to estimate the steady state flow rate in boiling-condensation natural circulation system is developed and compared with test results

  6. Safety significance of ATR [Advanced Test Reactor] passive safety response attributes

    International Nuclear Information System (INIS)

    Atkinson, S.A.

    1989-01-01

    The Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory was designed with some passive safety response attributes which contribute to the safety posture of the facility. The three passive safety attributes being evaluated in the paper are: (1) In-core and in-vessel natural convection cooling, (2) a passive heat sink capability of the ATR primary coolant system (PCS) for the transfer of decay power from the uninsulated piping to the confinement, and (3) gravity feed of emergency coolant makeup. The safety significance of the ATR passive safety response attributes is that the reactor can passively respond for most transients, given a reactor scram, to provide adequate decay power removal and a significant time for operator action should the normal active heat removal systems and their backup systems both fail. The ATR Interim Level 1 Probabilistic Risk Assessment (PRA) model ands results were used to evaluate the significance to ATR fuel damage frequency (or probability) of the above three passive response attributes. The results of the evaluation indicate that the first attribute is a major safety characteristic of the ATR. The second attribute has a noticeable but only minor safety significance. The third attribute has no significant influence on the ATR Level 1 PRA because of the diversity and redundancy of the ATR firewater injection system (emergency coolant system). 8 refs., 4 figs., 1 tab

  7. The PANDA tests for the SWR 1000 passive containment cooling system

    International Nuclear Information System (INIS)

    Dreier, J.; Aubert, C.; Huggenberger, M.; Strassberger, H.J.; Yadigaroglu, G.

    1999-01-01

    Since 1992, Siemens has been developing the SWR 1000, a new boiling water reactor with passive safety features. This development has been performed in close co-operation with the German nuclear utilities and with support from various European partners. Within the European Union sponsored project 'BWR R+D Cluster for Innovative Passive Safety Systems' and a bilateral contract between Siemens and the Paul Scherrer Institute, the passive containment cooling system of the SWR 1000 design has been investigated in the large-scale PANDA test facility at the Paul Scherrer Institute. A series of six tests were performed to simulate transients selected to cover a range of failure assumptions and accident severity, including core heat up and hydrogen generation. The results graphically demonstrate the self regulating character of the passive heat removal systems and their effectiveness, even under severe load, in limiting the containment pressurisation. Some tentative conclusions for the SWR 1000 are drawn, to be established by detailed analyses of the data, to support models and codes for application to plant transients. (author)

  8. The PANDA tests for the SWR 1000 passive containment cooling system

    International Nuclear Information System (INIS)

    Dreier, J.; Aubert, C.; Huggenberger, M.; Strassberger, H.J.; Meseth, J.; Yadigaroglu, G.

    1999-01-01

    Since 1992, Siemens has been developing the SWR 1000, a new boiling water reactor with passive safety features. This development has been performed in close co-operation with the German nuclear utilities and with support from various European partners. Within the European Union sponsored project 'BWR R and D Cluster for Innovative Passive Safety Systems' and a bilateral contract between Siemens and the Paul Scherrer Institute, the passive containment cooling system of the SWR 1000 design has been investigated in the large-scale PANDA test facility at the Paul Scherrer Institute. A series of six tests were performed to simulate transients selected to cover a range of failure assumptions and accident severity, including core heat up and hydrogen generation. The results graphically demonstrate the self regulating character of the passive heat removal systems and their effectiveness, even under severe load, in limiting the containment pressurisation. Some tentative conclusions for the SWR1000 are drawn, to be established by detailed analyses of the data, to support models and codes for application to plant transients. (author)

  9. Passive afterheat removal in the HTGR with the liner cooling system as a heat sink

    International Nuclear Information System (INIS)

    Rehm, W.; Jahn, W.; Verfondern, K.

    1984-09-01

    The report deals with the transients of temperature and system pressure and the fission product behaviour in the primary circuit of an HTGR during passive afterheat removal, where the liner cooling system of the PCRV serves as a heat sink. The analysis has been made for the PNP-500-reactor representing nuclear plants with medium thermal power. The investigations show that the liner cooling system is able to control a core heatup. High temperature loads are encountered in the upper core region. In the case of a reactor under pressure the fuel elements and the primary circuit remain intact as the first and second barriers for fission products. In the case of a depressurized primary circuit the liner cooling system also keeps the PCRV at normal operating temperatures. The effects of a core heatup on component damage and release of fission products are thus limited. (orig.) [de

  10. Role of passive valves & devices in poison injection system of advanced heavy water reactor

    International Nuclear Information System (INIS)

    Sapra, M.K.; Kundu, S.; Vijayan, P.K.; Vaze, K.K.; Sinha, R.K.

    2014-01-01

    The Advanced Heavy Water Reactor (AHWR) is a 300 MWe pressure tube type boiling light water (H 2 O) cooled, heavy water (D 2 O) moderated reactor. The reactor design is based on well-proven water reactor technologies and incorporates a number of passive safety features such as natural circulation core cooling; direct in-bundle injection of light water coolant during a Loss of Coolant Accident (LOCA) from Advanced Accumulators and Gravity Driven Water Pool by passive means; Passive Decay Heat Removal using Isolation Condensers, Passive Containment Cooling System and Passive Containment Isolation System. In addition to above, there is another passive safety system named as Passive Poison Injection System (PPIS) which is capable of shutting down the reactor for a prolonged time. It is an additional safety system in AHWR to fulfill the shutdown function in the event of failure of wired shutdown systems i.e. primary and secondary shut down systems of the reactor. When demanded, PPIS injects the liquid poison into the moderator by passive means using passive valves and devices. On increase of main heat transport (MHT) system pressure beyond a predetermined value, a set of rupture disks burst, which in-turn actuate the passive valve. The opening of passive valve initiates inrush of high pressure helium gas into poison tanks to push the poison into the moderator system, thereby shutting down the reactor. This paper primarily deals with design and development of Passive Poison Injection System (PPIS) and its passive valves & devices. Recently, a prototype DN 65 size Poison Injection Passive Valve (PIPV) has been developed for AHWR usage and tested rigorously under simulated conditions. The paper will highlight the role of passive valves & devices in PPIS of AHWR. The design concept and test results of passive valves along with rupture disk performance will also be covered. (author)

  11. Experiments on novel solar heating and cooling system

    International Nuclear Information System (INIS)

    Wang Yiping; Cui Yong; Zhu Li; Han Lijun

    2008-01-01

    Solar heating and nocturnal radiant cooling techniques are united to produce a novel solar heating and cooling system. The radiant panel with both heating and cooling functions can be used as structural materials for the building envelope, which realizes true building integrated utilization of solar energy. Based on the natural circulation principle, the operation status can be changed automatically between the heating cycle and the cooling cycle. System performances under different climate conditions using different covers on the radiant panel are studied. The results show that the novel solar heating and cooling system has good performance of heating and cooling. For the no cover system, the daily average heat collecting efficiency is 52% with the maximum efficiency of 73%, while at night, the cooling capacity is about 47 W/m 2 on a sunny day. On a cloudy day, the daily average heat collecting efficiency is 47% with the maximum of 84%, while the cooling capacity is about 33 W/m 2 . As a polycarbonate (PC) panel or polyethylene film are used as covers, the maximum heat collecting efficiencies are 75% and 72% and the daily average heat collecting efficiencies are 61% and 58%, while the cooling capacities are 50 W/m 2 and 36 W/m 2 , respectively

  12. Analysis of the passive heat removal enhancement for AP1000 containment due to the partially wetted coverage

    Energy Technology Data Exchange (ETDEWEB)

    Li, Cheng, E-mail: 510395453@qq.com [State Nuclear Power Technology Research & Development Center, 102209 Beijing (China); Li, Le [Tsinghua University, Institute of Nuclear and New Energy Technology, 100084 Beijing (China); Li, Junming [Tsinghua University, Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Thermal Engineering, Beijing 100084 (China); Zhang, Yajun [Tsinghua University, Institute of Nuclear and New Energy Technology, 100084 Beijing (China); Li, Zhihui [State Nuclear Power Technology Research & Development Center, 102209 Beijing (China)

    2017-03-15

    distributions. Results show that the maximum heat transfer enhancement can reach 63% and this enhancement peak appears when the dry strip fraction approximately equals 90%. The influences of dry coverage and dry-wet strip width were carefully discussed. It indicates that the heat transfer enhancement for small dry-wet strip is linear with dry strip fraction (0 < α < 80%). Finally, according to the wetted coverage ranges for AP1000 passive containment cooling system, an empirical correlation for heat transfer enhancement is given and it can be used to improve PCCS analysis.

  13. Analysis of the passive heat removal enhancement for AP1000 containment due to the partially wetted coverage

    International Nuclear Information System (INIS)

    Li, Cheng; Li, Le; Li, Junming; Zhang, Yajun; Li, Zhihui

    2017-01-01

    distributions. Results show that the maximum heat transfer enhancement can reach 63% and this enhancement peak appears when the dry strip fraction approximately equals 90%. The influences of dry coverage and dry-wet strip width were carefully discussed. It indicates that the heat transfer enhancement for small dry-wet strip is linear with dry strip fraction (0 < α < 80%). Finally, according to the wetted coverage ranges for AP1000 passive containment cooling system, an empirical correlation for heat transfer enhancement is given and it can be used to improve PCCS analysis.

  14. Highly air stable passivation of graphene based field effect devices.

    Science.gov (United States)

    Sagade, Abhay A; Neumaier, Daniel; Schall, Daniel; Otto, Martin; Pesquera, Amaia; Centeno, Alba; Elorza, Amaia Zurutuza; Kurz, Heinrich

    2015-02-28

    The sensitivity of graphene based devices to surface adsorbates and charge traps at the graphene/dielectric interface requires proper device passivation in order to operate them reproducibly under ambient conditions. Here we report on the use of atomic layer deposited aluminum oxide as passivation layer on graphene field effect devices (GFETs). We show that successful passivation produce hysteresis free DC characteristics, low doping level GFETs stable over weeks though operated and stored in ambient atmosphere. This is achieved by selecting proper seed layer prior to deposition of encapsulation layer. The passivated devices are also demonstrated to be robust towards the exposure to chemicals and heat treatments, typically used during device fabrication. Additionally, the passivation of high stability and reproducible characteristics is also shown for functional devices like integrated graphene based inverters.

  15. Passive and engineered safety features of the prototype fast reactor (PFR), Dounreay

    International Nuclear Information System (INIS)

    Gregory, C.V.

    1991-01-01

    Prototype fast reactor (PFR) combines passive and engineered safety features. Natural convection, a strong negative power coefficient, the decay heat removal system, and a fuel design able to operate beyond failure are all inherent and passive safety features of the PFR. The reliable shutdown system and the protection provided against SGU leaks are example of engineered protection. Experience at PFR demonstrates the worth and potential of a range of passive and engineered safeguards

  16. CFD modeling and thermal-hydraulic analysis for the passive decay heat removal of a sodium-cooled fast reactor

    International Nuclear Information System (INIS)

    Hung, T.C.; Dhir, V.K.; Chang, J.C.; Wang, S.K.

    2011-01-01

    Research highlights: → The COOLOD/N2 and PARET/ANL codes were used for a steady-state thermal-hydraulic and safety analysis of the 2 MW TRIGA MARK II reactor located at the Nuclear Studies Center of Maamora (CENM), Morocco. → The main objective of this study is to ensure the safety margins of different safety related parameters by steady-state calculations at full power level (2 MW). → The most important conclusion is that all obtained values of DNBR, fuel center and surface temperature, cladding surface temperature and coolant temperature across the hottest channel are largely far to compromise safety of the reactor. - Abstract: In this study, a pool-typed design similar to sodium-cooled fast reactor (SFR) of the fourth generation reactors has been modeled using CFD simulations to investigate the characteristics of a passive mechanism of Shutdown Heat Removal System (SHRS). The main aim is to refine the reactor pool design in terms of temperature safety margin of the sodium pool. Thus, an appropriate protection mechanism is maintained in order to ensure the safety and integrity of the reactor system during a shutdown mode without using any active heat removal system. The impacts on the pool temperature are evaluated based on the following considerations: (1) the aspect ratio of pool diameter to depth, (2) the values of thermal emissivity of the surface materials of reactor and guard vessels, and (3) innerpool liner and core periphery structures. The computational results show that an optimal pool design in geometry can reduce the maximum pool temperature down to ∼551 o C which is substantially lower than ∼627 o C as calculated for the reference case. It is also concluded that the passive Reactor Air Cooling System (RACS) is effective in removing decay heat after shutdown. Furthermore, thermal radiation from the surface of the reactor vessel is found to be important; and thus, the selection of the vessel surface materials with a high emissivity would be a

  17. Topology optimisation of passive coolers for light-emitting diode lamps

    DEFF Research Database (Denmark)

    Alexandersen, Joe

    2015-01-01

    This work applies topology optimisation to the design of passive coolers for light-emitting diode (LED) lamps. The heat sinks are cooled by the natural convection currents arising from the temperature difference between the LED lamp and the surrounding air. A large scale parallel computational....... The optimisation results show interesting features that are currently being incorporated into industrial designs for enhanced passive cooling abilities....

  18. Paraffin wax passivation layer improvements in electrical characteristics of bottom gate amorphous indium–gallium–zinc oxide thin-film transistors

    International Nuclear Information System (INIS)

    Chang, Geng-Wei; Chang, Ting-Chang; Syu, Yong-En; Tsai, Tsung-Ming; Chang, Kuan-Chang; Tu, Chun-Hao; Jian, Fu-Yen; Hung, Ya-Chi; Tai, Ya-Hsiang

    2011-01-01

    In this research, paraffin wax is employed as the passivation layer of the bottom gate amorphous indium–gallium–zinc oxide thin-film transistors (a-IGZO TFTs), and it is formed by sol–gel process in the atmosphere. The high yield and low cost passivation layer of sol–gel process technology has attracted much attention for current flat-panel-display manufacturing. Comparing with passivation-free a-IGZO TFTs, passivated devices exhibit a superior stability against positive gate bias stress in different ambient gas, demonstrating that paraffin wax shows gas-resisting characteristics for a-IGZO TFTs application. Furthermore, light-induced stretch-out phenomenon for paraffin wax passivated device is suppressed. This superior stability of the passivated device was attributed to the reduced total density of states (DOS) including the interfacial and semiconductor bulk trap densities.

  19. Active heat exchange system development for latent heat thermal energy storage

    Science.gov (United States)

    Alario, J.; Kosson, R.; Haslett, R.

    1980-01-01

    Various active heat exchange concepts were identified from among three generic categories: scrapers, agitators/vibrators and slurries. The more practical ones were given a more detailed technical evaluation and an economic comparison with a passive tube-shell design for a reference application (300 MW sub t storage for 6 hours). Two concepts were selected for hardware development: (1) a direct contact heat exchanger in which molten salt droplets are injected into a cooler counterflowing stream of liquid metal carrier fluid, and (2) a rotating drum scraper in which molten salt is sprayed onto the circumference of a rotating drum, which contains the fluid salt is sprayed onto the circumference of a rotating drum, which contains the fluid heat sink in an internal annulus near the surface. A fixed scraper blade removes the solidified salt from the surface which was nickel plated to decrease adhesion forces. In addition to improving performance by providing a nearly constant transfer rate during discharge, these active heat exchanger concepts were estimated to cost at least 25% less than the passive tube-shell design.

  20. The procurement and testing of the stainless steel in-vessel panels of the Wendelstein 7-X Stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Peacock, A., E-mail: alan.peacock@ipp.mpg.de [European Commission c/o Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Girlinger, A. [MAN Diesel and Turbo SE D-94469 Deggendorf (Germany); Vorkoeper, A. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 17491 Greifswald (Germany); Boscary, J.; Greuner, H. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Hurd, F. [European Commission c/o Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Mendelevitch, B.; Pirsch, H.; Stadler, R.; Zangl, G. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany)

    2011-10-15

    320 In-vessel water cooled stainless steel panels, poloidal closure plates and pumping gap panels, covering an area of approximately 100 m{sup 2}, are used in Wendelstein7-X to protect the plasma vessel. The panels are manufactured at Deggendorf, Germany by MAN Diesel and Turbo SE. The panels consist of a laser welded sandwich of stainless steel plates together with a labyrinth of cooling channels and have a complicated geometry to fit the plasma vessel of Wendelstein 7-X. The hydraulic and mechanical stability requirements whilst maintaining the tight tolerances for the shape of the components are very demanding. The panels are designed to operate at up to an average heat load of 100 kW/m{sup 2} and a maximum heat load of 200 kW/m{sup 2} with a water velocity of approximately 2 m s{sup -1}. High heat flux testing of an un-cooled panel at a time averaged load of 200 kW/m{sup 2} for 10 s were successfully performed to support the start up phase of Wendelstein 7-X operation. Extensive testing both during manufacture and after delivery to IPP-Garching demonstrates the suitability of the delivered panels for their purpose.

  1. From dodewaard to a modern economic passive plant-ESBWR

    International Nuclear Information System (INIS)

    Gonzalez Lopez, A.; Arnold, H.; Yadigaroglu, G.; Stoop, P.M.; Rao, A.

    1997-01-01

    For over 25 years the Dodewaard nuclear plant has produced electricity with one of the highest reliability of any power plant in the world. Almost 10 years ago when some designers looked at the features to incorporate in a modern mid-size BWR design, they chose some of the key features of Dodewaard natural circulation and passive safety. Over the years this design evolved into a 670 SBWR design that was developed by an international team and consisted of natural circulation and passive safety injection and decay heat removal. Since the passive decay heat removal was a major new technology area, an extensive test program was developed and conducted utilizing newly constructed large scale integrated system test facility at the Paul Scherrer Institute, Switzerland. The development of any modern reactor is time consuming and expensive, hence, the design and technology was done as part of an international team effort. This paper provides an overview of the international design and technology effort and discusses how the development costs were minimized through cooperation. (Author)

  2. Design of the inboard passive stabilizer for TPX

    International Nuclear Information System (INIS)

    Hoffmann, E.; Boonstra, R.; Baxi, C.B.; Chin, E.; Drees, L.; Lee, W.; Redler, K.L.; Reis, E.E.; Bialek, J.

    1995-01-01

    The Inboard Passive Stabilizer (IPS) is part of the plasma stabilizing system built into the TPX. Its purpose is to provide passive stabilization of the plasma vertical instability on short time scales. With carbon fiber composite (CFC) armor tiles it serves as a startup limiter, protects the vacuum vessel from radiation heat load during steady state operation and also functions as Neutral Beam armor. The inboard passive stabilizer is a saddle coil, constructed of a ring of copper plates, armored with CFC tiles, that surrounds the inner vacuum vessel at the midplane. The design of the plates, the support structure, cooling lines, CFC tiles and tile attach method is described. Tiles that experience only the normal heat load of 0.4 MW/m 2 are attached with mechanical fasteners. Tiles in the neutral beam shine through area are exposed to as much as 1.7 MW/m 2 and are brazed to the IPS. Significant forces are generated in the plates by the stabilization currents as well as during the frequent bakeout cycles. These plates are required to be fully remotely handled, including tile replacement, and the influence of this requirement on the design is discussed

  3. FLOW DISTRIBUTION IN A SOLAR COLLECTOR PANEL WITH HORIZONTAL FINS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    2005-01-01

    The objective of this work is to theoretically and experimentally investigate the flow and temperature distribution in a solar collector panel with an absorber consisting of horizontal fins. Fluid flow and heat transfer in the collector panel are studied by means of computational fluid dynamics...... (CFD) calculations. Further, experimental investigations of a 12.5 m² solar collector panel with 16 parallel connected horizontal fins are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the backside of the absorber tubes. The measured...

  4. Passive cooling of condensate chambers as retrofitting measure in boiling water reactors; Passive Kuehlung der Kondensationskammern in Siedewasserreaktoren als Nachruestmassnahme

    Energy Technology Data Exchange (ETDEWEB)

    Freis, Daniel; Nachtrodt, Frederik; Sporn, Michael; Tietsch, Wolfgang; Sassen, Felix [Westinghouse Electric Germany GmbH, Mannheim (Germany)

    2012-11-01

    Westinghouse Electric Germany GmbH has developed a concept for passive cooling of condensate chambers of BWR-type reactors. Due to its compactness the system is feasible as retrofitting measure. The passive condensate chamber cooling system is based on a cooling module with ascending and down pipe that are connected with the evaporation condenser to form a cooling circuit. Based on the consequent use of high-effective heat transport mechanisms, as boiling, condensation without non-condensable gases and mass transport a high cooling performance and compact construction is possible. The system is completely passive and completely diverse to existing active cooling systems. In the frame of a true-scale experiment the significant cooling performance was demonstrated. RELAP5 calculations confirmed the functionality of the cooling module.

  5. Displacements of Metallic Thermal Protection System Panels During Reentry

    Science.gov (United States)

    Daryabeigi, Kamran; Blosser, Max L.; Wurster, Kathryn E.

    2006-01-01

    Bowing of metallic thermal protection systems for reentry of a previously proposed single-stage-to-orbit reusable launch vehicle was studied. The outer layer of current metallic thermal protection system concepts typically consists of a honeycomb panel made of a high temperature nickel alloy. During portions of reentry when the thermal protection system is exposed to rapidly varying heating rates, a significant temperature gradient develops across the honeycomb panel thickness, resulting in bowing of the honeycomb panel. The deformations of the honeycomb panel increase the roughness of the outer mold line of the vehicle, which could possibly result in premature boundary layer transition, resulting in significantly higher downstream heating rates. The aerothermal loads and parameters for three locations on the centerline of the windward side of this vehicle were calculated using an engineering code. The transient temperature distributions through a metallic thermal protection system were obtained using 1-D finite volume thermal analysis, and the resulting displacements of the thermal protection system were calculated. The maximum deflection of the thermal protection system throughout the reentry trajectory was 6.4 mm. The maximum ratio of deflection to boundary layer thickness was 0.032. Based on previously developed distributed roughness correlations, it was concluded that these defections will not result in tripping the hypersonic boundary layer.

  6. BWR Passive Containment Cooling System by condensation-driven natural circulation

    International Nuclear Information System (INIS)

    Vierow, K.M.; Townsend, H.E.; Fitch, J.R.; Andersen, J.G.M.; Alamgir, M.; Schrock, V.E.

    1991-01-01

    A method of long-term decay heat removal which is safe, reliable, and passive has been incorporated into the design of the Simplified Boiling Water Reactor (SBWR). The primary functions of the Passive Containment Cooling System (PCCS) are to remove heat and maintain the containment pressure below allowable levels following a LOCA. A key component of the PCCS is the PCC condenser unit (PCC). By natural circulation, a steam-nitrogen mixture flows into the PCC heat exchanger, condensate drains to the reactor pressure vessel (RPV), and noncondensables are vented to the suppression chamber (S/C). This analysis focuses on three significant thermal-hydraulic phenomena which occur in the system. Specifically, steam condensation in the presence of a noncondensable, the PCC noncondensable venting and the natural circulation are discussed. Results of TRACG simulations are presented which show that the PCCS performs its intended functions. (author)

  7. Influence of the distribution of noncondensibles on passive containment condenser performance in PANDA

    International Nuclear Information System (INIS)

    Bandurski, T.; Huggenberger, M.; Dreier, J.; Aubert, C.; Putz, F.; Gamble, R.E.; Yadigaroglu, G.

    2001-01-01

    Recently, passive cooling systems have been designed for the long-term decay heat removal from the containment of Advanced Light Water Reactors. In particular, the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric European Simplified Boiling Water Reactor (ESBWR) has been tested in the large scale PANDA facility. The PANDA tests achieved the dual objective of improving confidence in the performance of the passive heat removal mechanisms underlying the design of the tested systems and extending the data base available for containment analysis code qualification. The tests conducted subject the PCCS to a variety of conditions representing design-basis and beyond-design-basis accident conditions. These include operation in the presence of both heavier and lighter than steam noncondensible gases as well as a variety of asymmetric conditions and challenging start-up conditions. The present paper addresses the transient distribution of noncondensibles and their effect on the passive condenser performance in PANDA

  8. Influence of the distribution of noncondensibles on passive containment condenser performance in PANDA

    Energy Technology Data Exchange (ETDEWEB)

    Bandurski, T. E-mail: thomas.bandurski@psi.ch; Huggenberger, M.; Dreier, J.; Aubert, C.; Putz, F.; Gamble, R.E. E-mail: robert.gamble@gene.ge.com; Yadigaroglu, G. E-mail: yadigaroglu@iet.mavt.ethz.ch

    2001-02-01

    Recently, passive cooling systems have been designed for the long-term decay heat removal from the containment of Advanced Light Water Reactors. In particular, the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric European Simplified Boiling Water Reactor (ESBWR) has been tested in the large scale PANDA facility. The PANDA tests achieved the dual objective of improving confidence in the performance of the passive heat removal mechanisms underlying the design of the tested systems and extending the data base available for containment analysis code qualification. The tests conducted subject the PCCS to a variety of conditions representing design-basis and beyond-design-basis accident conditions. These include operation in the presence of both heavier and lighter than steam noncondensible gases as well as a variety of asymmetric conditions and challenging start-up conditions. The present paper addresses the transient distribution of noncondensibles and their effect on the passive condenser performance in PANDA.

  9. Study of passive residual heat removal system of a modular small PWR reactor; Estudo do sistema passivo de remoção de calor residual de um reator PWR pequeno modular

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Nathália N., E-mail: nathalianunes@poli.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Departamento de Engenharia Nuclear; Faccini, José L.H., E-mail: faccini@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Su, Jian, E-mail: sujian@lasme.coppe.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2017-07-01

    This paper presents a study on the passive residual heat removal system (PRHRS) of a small modular nuclear reactor (SMR) of 75MW. More advanced nuclear reactors, such as generation III + and IV, have passive safety systems that automatically go into action in order to prevent accidents. The purpose of the PRHRS is to transfer the decay heat from the reactor's nuclear fuel, keeping the core cooled after the plant has shut down. It starts operating in the event of fall of power supply to the nuclear station, or in the event of an unavailability of the steam generator water supply system. Removal of decay heat from the core of the reactor is accomplished by the flow of the primary refrigerant by natural circulation through heat exchangers located in a pool filled with water located above the core. The natural circulation is caused by the density gradient between the reactor core and the pool. A thermal and comparative analysis of the PRHRS was performed consisting of the resolution of the mass conservation equations, amount of movement and energy and using incompressible fluid approximations with the Boussinesq approximation. Calculations were performed with the aid of Mathematica software. A design of the heat exchanger and the cooling water tank was done so that the core of the reactor remained cooled for 72 hours using only the PRHRS.

  10. An analytical and experimental investigation of active structural acoustic control of noise transmission through double panel systems

    Science.gov (United States)

    Carneal, James P.; Fuller, Chris R.

    2004-05-01

    An analytical and experimental investigation of active control of sound transmission through double panel systems has been performed. The technique used was active structural acoustic control (ASAC) where the control inputs, in the form of piezoelectric actuators, were applied to the structure while the radiating pressure field was minimized. Results verify earlier experimental investigations and indicate the application of control inputs to the radiating panel of the double panel system resulted in greater transmission loss (TL) due to its direct effect on the nature of the structural-acoustic (or radiation) coupling between the radiating panel and the receiving acoustic space. Increased control performance was seen in a double panel system consisting of a stiffer radiating panel due to its lower modal density and also as a result of better impedance matching between the piezoelectric actuator and the radiating plate. In general the results validate the ASAC approach for double panel systems, demonstrating that it is possible to take advantage of double panel system passive behavior to enhance control performance, and provide design guidelines.

  11. Parametric analysis of the operation of nocturnal radiative cooling panels coupled with in room PCM ceiling panels

    DEFF Research Database (Denmark)

    Bourdakis, Eleftherios; Kazanci, Ongun Berk; Péan, T.Q.

    2017-01-01

    03:00 and get activated when the temperature in the storage tank was below 21°C, 69.8°F, activate the heat pump no earlier than 05:00 and get activated when the temperature in the storage tank was below 15°C, 59°F, and lastly have a temperature difference between the output of the solar panels......The scope of this parametric simulation study was to identify the optimal combination of set-points for different parameters of a radiant PCM ceiling panels cooling system that will result in the best indoor thermal environment with the least possible energy use. The results showed that for each...

  12. Effects of fatigue and environment on residual strengths of center-cracked graphite/epoxy buffer strip panels

    Science.gov (United States)

    Bigelow, Catherine A.

    1989-01-01

    The effects of fatigue, moisture conditioning, and heating on the residual tension strengths of center-cracked graphite/epoxy buffer strip panels were evaluated using specimens made with T300/5208 graphite epoxy in a 16-ply quasi-isotropic layup, with two different buffer strip materials, Kevlar-49 or S-glass. It was found that, for panels subjected to fatigue loading, the residual strengths were not significantly affected by the fatigue loading, the number of repetitions of the loading spectrum, or the maximum strain level. The moisture conditioning reduced the residual strengths of the S-glass buffer strip panels by 10 to 15 percent below the ambient results, but increased the residual strengths of the Kevlar-49 buffer strip panels slightly. For both buffer strip materials, the heat increased the residual strengths of the buffer strip panels slightly over the ambient results.

  13. Simulation of boiling flow in evaporator of separate type heat pipe with low heat flux

    International Nuclear Information System (INIS)

    Kuang, Y.W.; Wang, Wen; Zhuan, Rui; Yi, C.C.

    2015-01-01

    Highlights: • A boiling flow model in a separate type heat pipe with 65 mm diameter tube. • Nucleate boiling is the dominant mechanism in large pipes at low mass and heat flux. • The two-phase heat transfer coefficient is less sensitive to the total mass flux. - Abstract: The separate type heat pipe heat exchanger is considered to be a potential selection for developing passive cooling spent fuel pool – for the passive pressurized water reactor. This paper simulates the boiling flow behavior in the evaporator of separate type heat pipe, consisting of a bundle of tubes of inner diameter 65 mm. It displays two-phase characteristic in the evaporation section of the heat pipe working in low heat flux. In this study, the two-phase flow model in the evaporation section of the separate type heat pipe is presented. The volume of fluid (VOF) model is used to consider the interaction between the ammonia gas and liquid. The flow patterns and flow behaviors are studied and the agitated bubbly flow, churn bubbly flow are obtained, the slug bubble is likely to break into churn slug or churn froth flow. In addition, study on the heat transfer coefficients indicates that the nucleate boiling is the dominant mechanism in large pipes at low mass and heat flux, with the heat transfer coefficient being less sensitive to the total mass flux

  14. Photovoltaic solar panel for a hybrid PV/thermal system

    Energy Technology Data Exchange (ETDEWEB)

    Zakharchenko, R.; Licea-Jimenez, L.; Perez-Garcia, S.A.; Perez-Robles, J.F.; Gonzalez-Hernandez, J.; Vorobiev, Y. [CINVESTAV-Queretaro, (Mexico); Vorobiev, P. [Universidad Autonoma de Queretaro, (Mexico). Facultad de Ingenieria; Dehesa-Carrasco, U. [Instituto Tec. Del Istmo, Oaxaco (Mexico). Dep. de Ingenieria Electromecanica

    2004-05-01

    The hybrid PV-thermal system was studied, with the photovoltaic panel (PVP) area much smaller than that of the solar collector. Performance of the different panels in the system was investigated, in particular, those made of crystalline (c-) Si, {alpha}-Si and CuInSe{sub 2} as well as different materials and constructions for the thermal contact between the panel and the collector. Our conclusion is that the PVP for application in a hybrid system needs a special design providing efficient heat extraction from it. PVP was designed and made. Its study has shown that this design provides the high electrical and thermal efficiency of the hybrid system. (author)

  15. Natural circulating passive cooling system for nuclear reactor containment structure

    Science.gov (United States)

    Gou, Perng-Fei; Wade, Gentry E.

    1990-01-01

    A passive cooling system for the contaminant structure of a nuclear reactor plant providing protection against overpressure within the containment attributable to inadvertent leakage or rupture of the system components. The cooling system utilizes natural convection for transferring heat imbalances and enables the discharge of irradiation free thermal energy to the atmosphere for heat disposal from the system.

  16. Active charge, passive discharge floor space heating system

    Energy Technology Data Exchange (ETDEWEB)

    Salt, H.; Mahoney, K.J.

    1987-01-01

    This space heating system has a rockbed beneath and in contact with the floor of a dwelling, which is heated by radiation and convection from the floor. The ability of the heating system to maintain comfort conditions with no additional energy input is discussed and it is shown that the system is more suitable for use in mild climates than severe ones. Experimental work on horizontal air flow rockbeds is reported and shows that shallow beds can be designed in the same way as vertical air flow beds. The influence of natural convection on the effective thermal conductivity of the experimental rockbeds is reported.

  17. The effect of diffuse ceiling panel on the energy performance of thermally activated building construction

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Pomianowski, Michal Zbigniew

    2016-01-01

    An integrated system combining diffuse ceiling ventilation with thermally activated building construction (TABS) was proposed recently. In this system, TABS is encapsulated by diffuse ceiling panel and cannot have directly heat exchange with the room. The aim of this study is to investigate...... the effect of diffuse ceiling panel on the energy performance of TABS in both heat and cooling mode. Experiments are carried out in a full-scale test facility with the integrated system, and the cases without diffuse ceiling are also measured as references. The results indicate that the diffuse ceiling has...... an opposite effect on the heating and cooling capacity of TABS. In addition, a numerical model is built and validated by the measured data. The validated model is further applied to conduct a paramedical study on the materials of the diffuse ceiling panel....

  18. Control source development for reduction of noise transmitted through a double panel structure

    NARCIS (Netherlands)

    Ho, J.

    2014-01-01

    A double panel structure, which consists of two panels with air in between, is widely adopted in many applications such as aerospace, automotive industries, and buildings due to its low sound transmission at high frequencies, low heat transmission, and low weight. Nevertheless, the resonance of the

  19. A comprehensive assessment of the life cycle energy demand of passive houses

    International Nuclear Information System (INIS)

    Stephan, André; Crawford, Robert H.; Myttenaere, Kristel de

    2013-01-01

    Highlights: • The life cycle energy demand of a passive house (PH) is measured over 100 years. • Embodied, operational and user transport energy demand are considered. • Embodied energy represents the highest energy consumption in all variations. • A PH might not save energy compared to a standard house. • A poorly insulated city apartment can use less energy than a best case suburban PH. - Abstract: Certifications such as the Passive House aim to reduce the final space heating energy demand of residential buildings. The latter are responsible for a significant share of final energy consumption in Europe of which nearly 70% is associated with space conditioning, notably heating. The improvement of the energy efficiency of residential buildings, in terms of space heating, can therefore reduce their total energy demand. However, most certifications totally overlook other energy requirements associated with residential buildings. Studies on passive houses do not take into consideration the embodied energy required to manufacture the building materials, especially the large amount of insulation required to achieve high operational efficiencies. At an urban scale, most passive houses are single family detached houses located in low density suburbs with a high car usage, resulting in considerable transport related energy demand. This paper analyses the total life cycle energy demand of a typical Belgian passive house, comprising embodied, operational and transport energy. It relies on a comprehensive technique developed by Stephan et al. [1] and conducts a parametric analysis as well as a comparison to alternative building types. Results show that current building energy efficiency certifications might not ensure a lower energy demand and can, paradoxically result in an increased energy consumption because of their limited scope. More comprehensive system boundaries should be used to make sure that net energy savings do occur. The embodied energy of passive

  20. The REPAS approach to the evaluation of passive safety systems reliability

    International Nuclear Information System (INIS)

    Bianchi, F.; Burgazzi, L.; D'Auria, F.; Ricotti, M.E.

    2002-01-01

    Scope of this research, carried out by ENEA in collaboration with University of Pisa and Polytechnic of Milano since 1999, is the identification of a methodology allowing the evaluation of the reliability of passive systems as a whole, in a more physical and phenomenal way. The paper describe the study, named REPAS (Reliability Evaluation of Passive Safety systems), carried out by the partners and finalised to the development and validation of such a procedure. The strategy of engagement moves from the consideration that a passive system should be theoretically more reliable than an active one. In fact it does not need any external input or energy to operate and it relies only upon natural physical laws (e.g. gravity, natural circulation, internally stored energy, etc.) and/or 'intelligent' use of the energy inherently available in the system (e.g. chemical reaction, decay heat, etc.). Nevertheless the passive system may fail its mission not only as a consequence of classical mechanical failure of components, but also for deviation from the expected behaviour, due to physical phenomena mainly related to thermal-hydraulics or due to different boundary and initial conditions. The main sources of physical failure are identified and a probability of occurrence is assigned. The reliability analysis is performed on a passive system which operates in two-phase, natural circulation. The selected system is a loop including a heat source and a heat sink where the condensation occurs. The system behaviour under different configurations has been simulated via best-estimate code (Relap5 mod3.2). The results are shown and can be treated in such a way to give qualitative and quantitative information on the system reliability. Main routes of development of the methodology are also depicted. The analysis of the results shows that the procedure is suitable to evaluate the performance of a passive system on a probabilistic / deterministic basis. Important information can also be

  1. Effects of post heat-treatment on surface characteristics and adhesive bonding performance of medium density fiberboard

    Science.gov (United States)

    Nadir Ayrilimis; Jerrold E. Winandy

    2009-01-01

    A series of commercially manufactured medium density fiberboard (MDF) panels were exposed to a post-manufacture heat-treatment at various temperatures and durations using a hot press and just enough pressure to ensure firm contact between the panel and the press platens. Post-manufacture heat-treatment improved surface roughness of the exterior MDF panels. Panels...

  2. A thermal model for photovoltaic panels under varying atmospheric conditions

    International Nuclear Information System (INIS)

    Armstrong, S.; Hurley, W.G.

    2010-01-01

    The response of the photovoltaic (PV) panel temperature is dynamic with respect to the changes in the incoming solar radiation. During periods of rapidly changing conditions, a steady state model of the operating temperature cannot be justified because the response time of the PV panel temperature becomes significant due to its large thermal mass. Therefore, it is of interest to determine the thermal response time of the PV panel. Previous attempts to determine the thermal response time have used indoor measurements, controlling the wind flow over the surface of the panel with fans or conducting the experiments in darkness to avoid radiative heat loss effects. In real operating conditions, the effective PV panel temperature is subjected to randomly varying ambient temperature and fluctuating wind speeds and directions; parameters that are not replicated in controlled, indoor experiments. A new thermal model is proposed that incorporates atmospheric conditions; effects of PV panel material composition and mounting structure. Experimental results are presented which verify the thermal behaviour of a photovoltaic panel for low to strong winds.

  3. Experimental and numerical results from hybrid retrofitted photovoltaic panels

    International Nuclear Information System (INIS)

    Rossi, Cecilia; Tagliafico, Luca A.; Scarpa, Federico; Bianco, Vincenzo

    2013-01-01

    Highlights: • The experimental study focuses on the feasibility of hybrid PV/T panels retrofitting. • The critical role of a thin layer of air between PV panel and back plate is evidenced. • The benefit of the addition of a conductive paste layer is analyzed via FEM simulations. • The use of wood ribs to stick the back plate represents a cheap effective solution. - Abstract: The aim of present study is to investigate different methodologies to achieve a better contact between a photovoltaic panel and a thermal plate, in order to cool the PV panel by means of water in the perspective of coupling it with a heat pump. It is believed that this kind of system allows to obtain a higher energy efficiency. The analysis is developed both experimentally and numerically, testing different kinds of configurations in different operating conditions. Simulations are employed to analyze the effect of the variations of the contact resistance between the panel and the thermal plates, demonstrating that the use of a conductive paste increases the overall performance of the panel. Results show interesting possibilities in terms of retrofitting of existing photovoltaic panels by employing very simple solutions, such as to fix the thermal plate on the rear of the panel by means of wood ribs

  4. Single-tube condensation experiment in Passive Auxiliary Feedwater System of APR1400+

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Chang Wook; No, Hee Cheon; Yun, Bong Yo; Jeon, Byong Guk [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2012-05-15

    Conventional Korean nuclear power plants, Advanced Power Reactors (APR), are characterized by an active cooling system. However, Active cooling system may not prevent significant damage without any AC power source available for its operation as vividly illustrated through the recent Fukushima incident. In the APR1400+ to be designed, an independent passive cooling system was added in order to overcome the aforementioned shortcomings. In the Passive Auxiliary Feedwater System (PAFS), gravity force and density difference between steam and water are used. The system comprises of 240 condensation tubes to efficiently remove decay heat. Before applying the PAFS to APR1400+, the system's safety and heat removal performance must be verified. The present study experimentally evaluates the heat removal performance of a single tube in the PAFS. The objectives of SCOP (Single-tube Condensation experiment facility of PAFS) are the evaluation of the heat removal performance in the tube of the PAFS and database construction under various tube designs and test conditions. Reaching these objectives, we developed advanced measurement techniques for the amount of moisture, heat flux, and water film thickness.

  5. Influence of the distribution of non-condensables on passive containment condenser performance in PANDA

    International Nuclear Information System (INIS)

    Bandurski, Th.; Huggenberger, M.; Dreier, J.; Aubert, C.; Putz, F.; Gamble, R.E.; Yadigaroglu, G.

    2001-01-01

    Recently passive cooling systems have been designed for the long-term decay heat removal from the containment of Advanced Light Water Reactors. In particular, the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric European Simplified Boiling Water Reactor (ESBWR) has been tested in the large-scale PANDA facility. The PANDA tests achieved the dual objectives of improving confidence in the performance of the passive heat removal mechanisms underlying the design of the system, and extending the database available for containment analysis code qualification. The tests conducted subject the PCCS to a variety of conditions representing design-basis and beyond-design-basis accident conditions. These include operation in the presence of both heavier and lighter than steam non-condensable gases, as well as a variety of asymmetric and challenging start-up conditions. The present paper addresses the transient distribution of non-condensables in PANDA, and their effect on (passive) condenser performance. (author)

  6. Influence of the distribution of non-condensables on passive containment condenser performance in PANDA

    Energy Technology Data Exchange (ETDEWEB)

    Bandurski, Th.; Huggenberger, M.; Dreier, J.; Aubert, C.; Putz, F.; Gamble, R.E.; Yadigaroglu, G

    2001-03-01

    Recently passive cooling systems have been designed for the long-term decay heat removal from the containment of Advanced Light Water Reactors. In particular, the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric European Simplified Boiling Water Reactor (ESBWR) has been tested in the large-scale PANDA facility. The PANDA tests achieved the dual objectives of improving confidence in the performance of the passive heat removal mechanisms underlying the design of the system, and extending the database available for containment analysis code qualification. The tests conducted subject the PCCS to a variety of conditions representing design-basis and beyond-design-basis accident conditions. These include operation in the presence of both heavier and lighter than steam non-condensable gases, as well as a variety of asymmetric and challenging start-up conditions. The present paper addresses the transient distribution of non-condensables in PANDA, and their effect on (passive) condenser performance. (author)

  7. Thermic diode performance characteristics and design manual

    Science.gov (United States)

    Bernard, D. E.; Buckley, S.

    1979-01-01

    Thermic diode solar panels are a passive method of space and hot water heating using the thermosyphon principle. Simplified methods of sizing and performing economic analyses of solar heating systems had until now been limited to passive systems. A mathematical model of the thermic diode including its high level of stratification has been constructed allowing its performance characteristics to be studied. Further analysis resulted in a thermic diode design manual based on the f-chart method.

  8. Passive cooling application in the north of Morocco

    International Nuclear Information System (INIS)

    Ahachad, M.; Draoui, A.; Belarbi, R.; Allard, F.

    2006-01-01

    According to the inter-professional union of the poultry farm sector in Morocco, the heat stress, during the last summer, has led to ones of heavy losses estimated of about ten million Euros at producers. In this paper the measures which could be used to reduce the fatal effect of heat stress phenomenon are presented. This is achieved by modeling and simulation of a typical poultry house in the north of Morocco. A case study was realized to show the influence of each parameter on the behaviour of the building. The most influential parameters are: ventilation shape, orientation, number of the occupants...etc. The evaporative cooling systems models were linked to thermal building software, TRNSYS, and the assessment of poultry house equipped with passive cooling systems will be presented. The simulations show that the heat stress phenomenon could be avoided. The experimental study of the poultry house equipped with a passive cooling system shows a decrease of temperature of the internal air from 5 to 9 degree centigrade, and an amelioration of quality of production, which is translated by an important decrease of mortality number and an increase of poultry weight.(Author)

  9. Modal analysis and acoustic transmission through offset-core honeycomb sandwich panels

    Science.gov (United States)

    Mathias, Adam Dustin

    The work presented in this thesis is motivated by an earlier research that showed that double, offset-core honeycomb sandwich panels increased thermal resistance and, hence, decreased heat transfer through the panels. This result lead to the hypothesis that these panels could be used for acoustic insulation. Using commercial finite element modeling software, COMSOL Multiphysics, the acoustical properties, specifically the transmission loss across a variety of offset-core honeycomb sandwich panels, is studied for the case of a plane acoustic wave impacting the panel at normal incidence. The transmission loss results are compared with those of single-core honeycomb panels with the same cell sizes. The fundamental frequencies of the panels are also computed in an attempt to better understand the vibrational modes of these particular sandwich-structured panels. To ensure that the finite element analysis software is adequate for the task at hand, two relevant benchmark problems are solved and compared with theory. Results from these benchmark results compared well to those obtained from theory. Transmission loss results from the offset-core honeycomb sandwich panels show increased transmission loss, especially for large cell honeycombs when compared to single-core honeycomb panels.

  10. Precipitation and Latent Heating Distributions from Satellite Passive Microwave Radiometry. Part 1; Improved Method and Uncertainties

    Science.gov (United States)

    Olson, William S.; Kummerow, Christian D.; Yang, Song; Petty, Grant W.; Tao, Wei-Kuo; Bell, Thomas L.; Braun, Scott A.; Wang, Yansen; Lang, Stephen E.; Johnson, Daniel E.; hide

    2006-01-01

    A revised Bayesian algorithm for estimating surface rain rate, convective rain proportion, and latent heating profiles from satellite-borne passive microwave radiometer observations over ocean backgrounds is described. The algorithm searches a large database of cloud-radiative model simulations to find cloud profiles that are radiatively consistent with a given set of microwave radiance measurements. The properties of these radiatively consistent profiles are then composited to obtain best estimates of the observed properties. The revised algorithm is supported by an expanded and more physically consistent database of cloud-radiative model simulations. The algorithm also features a better quantification of the convective and nonconvective contributions to total rainfall, a new geographic database, and an improved representation of background radiances in rain-free regions. Bias and random error estimates are derived from applications of the algorithm to synthetic radiance data, based upon a subset of cloud-resolving model simulations, and from the Bayesian formulation itself. Synthetic rain-rate and latent heating estimates exhibit a trend of high (low) bias for low (high) retrieved values. The Bayesian estimates of random error are propagated to represent errors at coarser time and space resolutions, based upon applications of the algorithm to TRMM Microwave Imager (TMI) data. Errors in TMI instantaneous rain-rate estimates at 0.5 -resolution range from approximately 50% at 1 mm/h to 20% at 14 mm/h. Errors in collocated spaceborne radar rain-rate estimates are roughly 50%-80% of the TMI errors at this resolution. The estimated algorithm random error in TMI rain rates at monthly, 2.5deg resolution is relatively small (less than 6% at 5 mm day.1) in comparison with the random error resulting from infrequent satellite temporal sampling (8%-35% at the same rain rate). Percentage errors resulting from sampling decrease with increasing rain rate, and sampling errors in

  11. Influence of Indoor Environment and Occupant Behaviour on Energy Consumption in Passive House Apartments

    DEFF Research Database (Denmark)

    Skød Søvsø, Asger; Peuhkuri, Ruut; Andersen, Rune Korsholm

    2015-01-01

    In 2012 Køge Boligselskab built 9 building blocks totalling 126 passive house apartments. Their monitored space heating demand (SHD) has been a lot higher than the passive house requirements. The aim of this study was to identify why, and how it relates to indoor environment and occupant behaviour...

  12. Poloidal and toroidal heat flux distribution in the CCT tokamak

    International Nuclear Information System (INIS)

    Brown, M.L.; Dhir, V.K.; Taylor, R.J.

    1990-01-01

    Plasma heat flux to the Faraday shield panels of the UCLA Continuous Current Tokamak (CCT) has been measured calorimetrically in order to identify the dominant parameters affecting the spatial distribution of heat deposition. Three heating methods were investigated: audio frequency discharge cleaning, RF heating, and AC ohmic. Significant poloidal asymmetry is present in the heat flux distribution. On the average, the outer panels received 25-30% greater heat flux than the inner ones, with the ratio of maximum to minimum values attaining a difference of more than a factor of 2. As a diagnostic experiment the current to a selected toroidal field coil was reduced in order to locally deflect the toroidal field lines outward in a ripple-like fashion. Greatly enhanced heat deposition (up to a factor of 4) was observed at this location on the outside Faraday panels. The enhancement was greatest for conditions of low toroidal field and low neutral pressure, leading to low plasma densities, for which Coulomb collisions are the smallest. An exponential model based on a heat flux e-folding length describes the experimentally found localization of thermal energy quite adequately. (orig.)

  13. Thulium-170 heat source

    Science.gov (United States)

    Walter, Carl E.; Van Konynenburg, Richard; VanSant, James H.

    1992-01-01

    An isotopic heat source is formed using stacks of thin individual layers of a refractory isotopic fuel, preferably thulium oxide, alternating with layers of a low atomic weight diluent, preferably graphite. The graphite serves several functions: to act as a moderator during neutron irradiation, to minimize bremsstrahlung radiation, and to facilitate heat transfer. The fuel stacks are inserted into a heat block, which is encased in a sealed, insulated and shielded structural container. Heat pipes are inserted in the heat block and contain a working fluid. The heat pipe working fluid transfers heat from the heat block to a heat exchanger for power conversion. Single phase gas pressure controls the flow of the working fluid for maximum heat exchange and to provide passive cooling.

  14. Finite element analysis of high modal dynamic responses of a composite floor subjected to human motion under passive live load

    Directory of Open Access Journals (Sweden)

    Arash Behnia

    Full Text Available Light weight and long span composite floors are common place in modern construction. A critical consequence of this application is undesired vibration which may cause excessive discomfort to occupants. This work investigates the composite floor vibration behavior of an existing building based on a comprehensive study of high modal dynamic responses, the range of which has been absent in previous studies and major analytical templates, of different panels under the influence of loads induced by human motion. The resulting fundamental natural frequency and vibration modes are first validated with respect to experimental and numerical evidences from literature. Departing from close correlation established in comparison, this study explores in detail the effects of intensity of passive live load as additional stationary mass due to crowd jumping as well as considering human structure interaction. From observation, a new approach in the simulation of passive live load through the consideration of human structure interaction and human body characteristics is proposed. It is concluded that higher vibration modes are essential to determine the minimum required modes and mass participation ratio in the case of vertical vibration. The results indicate the need to consider 30 modes of vibration to obtain all possible important excitations and thereby making third harmonic of load frequency available to excite the critical modes. In addition, presence of different intensities of passive live load on the composite floor showed completely different behavior in each particular panel associated with load location of panel and passive live load intensity. Furthermore, implementing human body characteristics in simulation causes an obvious increase in modal damping and hence better practicality and economical presentation can be achieved in structural dynamic behavior.

  15. Fabrication of a first wall panel by diffusion bonding

    International Nuclear Information System (INIS)

    Moreschi, L.F.; Pizzuto, A.; Alessandrini, I.

    2002-01-01

    Separated First Wall Panels mechanically attached to a shield block is now the reference concept for the Primary Wall Modules of RTO/RC ITER. The objective of the present work is to demonstrate the practical feasibility of a First Wall Panel utilizing a duplex round (steel) in square (copper) heat sink wound around a steel core and covered by Beryllium armour tiles. These three different materials (Be, Cu, steel) are joined together by diffusion bonding. The Copper alloy/stainless steel and Copper alloy/Beryllium joints were studied and developed selecting the optimal parameters for the related diffusion process. Several specimens were manufactured to be mechanically and thermally tested. The joints were mechanically tested using dedicated press equipment and investigated by micro-structural analysis with optical and SEM microscopy. Some thermal tests were finally carried out using an Electron Beam Facility. A dedicated R and D programme has led to the development of a co-drawing process, suitable for manufacturing the duplex Copper alloy-stainless steel heat sink. Two mock-ups were manufactured, the first in reduced-scale to test the thermal performance of the system, the second of larger scale and geometry better to represent the First Wall Panel

  16. Control source development for reduction of noise transmitted through a double panel structure

    OpenAIRE

    Ho, J.

    2014-01-01

    A double panel structure, which consists of two panels with air in between, is widely adopted in many applications such as aerospace, automotive industries, and buildings due to its low sound transmission at high frequencies, low heat transmission, and low weight. Nevertheless, the resonance of the cavity and the poor sound transmission loss at low frequencies limit the double panel’s noise control performance. Applying active structural acoustic control to the panels or active noise control ...

  17. Consolidation of HIP bonding technologies for the ITER first wall panels

    International Nuclear Information System (INIS)

    Sherlock, P.; Peacock, A.; Roedig, M.

    2006-01-01

    Over the last decade alternative technologies for the manufacture of the ITER first wall have been progressively developed. Now, as the build of ITER approaches, the manufacturing route is being consolidated around the best solutions found to date. The design of the first wall is based on the concept of blanket modules, each faced by separable first wall panels. For the manufacture of the first wall panels two HIP bonding technologies are proposed by AMEC NNC; the first to bond together the composite copper alloy / stainless steel heat sink base, the second to bond the beryllium tiles to the copper alloy surface of the heat sink base. These technologies have been developed incrementally through the use of experiments, part scale mock-ups and full scale first wall panel prototypes. This paper reviews the development of the HIP bonding technologies identified above and discusses the latest results from components produced by AMEC NNC under the auspices of EFDA. The manufacturing stages, non-destructive examination and heat flux test results from the work are presented for the latest first wall mock-up components. Conclusions are then drawn with regard to the important aspects for the series production of components for ITER. (author)

  18. Positioning Your Library for Solar (and Financial) Gain. Improving Energy Efficiency, Lighting, and Ventilation with Primarily Passive Techniques

    Science.gov (United States)

    Shane, Jackie

    2012-01-01

    This article stresses the importance of building design above technology as a relatively inexpensive way to reduce energy costs for a library. Emphasis is placed on passive solar design for heat and daylighting, but also examines passive ventilation and cooling, green roofs, and building materials. Passive design is weighed against technologies…

  19. Thermal Modeling of the Mars Reconnaissance Orbiter's Solar Panel and Instruments during Aerobraking

    Science.gov (United States)

    Dec, John A.; Gasbarre, Joseph F.; Amundsen, Ruth M.

    2007-01-01

    The Mars Reconnaissance Orbiter (MRO) launched on August 12, 2005 and started aerobraking at Mars in March 2006. During the spacecraft s design phase, thermal models of the solar panels and instruments were developed to determine which components would be the most limiting thermally during aerobraking. Having determined the most limiting components, thermal limits in terms of heat rate were established. Advanced thermal modeling techniques were developed utilizing Thermal Desktop and Patran Thermal. Heat transfer coefficients were calculated using a Direct Simulation Monte Carlo technique. Analysis established that the solar panels were the most limiting components during the aerobraking phase of the mission.

  20. Heave and Flow: Understanding the role of resonance and shape evolution for heaving flexible panels

    Science.gov (United States)

    Hoover, Alexander; Cortez, Ricardo; Tytell, Eric; Fauci, Lisa

    2017-11-01

    Many animals that swim or fly use their body to accelerate the fluid around them, transferring momentum from their bodies to the surrounding fluid. The emergent kinematics from this transfer are a result of the coupling between the fluid and the material properties of the body. Here we present a computational study of a 3-dimensional flexible panel that is heaved at its leading edge in an incompressible, viscous fluid. These high-fidelity numerical simulations enable us to examine the role of resonance, fluid forces, and panel deformations have on swimming performance. Varying both the passive material properties and the heaving frequency of the panel, we find peaks in trailing edge amplitude and forward swimming speed are determined by a dimensionless quantity, the effective flexibility. Modal decompositions of panel deflections reveal that the strength of each mode is related to the effective flexibility and peaks in the swimming speed and trailing edge amplitude correspond to peaks in the contributions of different modes. Panels of different material properties but with similar effective flexibilities have modal contributions that evolve similarly over the phase of the heaving cycle and agreement in dominant vortex structures generated by the panel. NSF RTG 1043626.

  1. Effects of moisture, elevated temperature, and fatigue loading on the behavior of graphite/epoxy buffer strip panels with center cracks

    Science.gov (United States)

    Bigelow, C. A.

    1988-01-01

    The effects of fatigue loading combined with moisture and heat on the behavior of graphite epoxy panels with either Kevlar-49 or S-glass buffer strips were studied. Buffer strip panels, that had a slit in the center to represent damage, were moisture conditioned or heated, fatigue loaded, and then tested in tension to measure their residual strength. The buffer strips were parallel to the loading direction and were made by replacing narrow strips of the 0 deg graphite plies with Kevlar-49 epoxy or S-glass epoxy on a 1-for-1 basis. The panels were subjected to a fatigue loading spectrum. One group of panels was preconditioned by soaking in 60 C water to produce a 1 percent weight gain then tested at room temperature. One group was heated to 82 C during the fatigue loading. Another group was moisture conditioned and then tested at 82 C. The residual strengths of the buffer panels were not highly affected by the fatigue loading, the number of repetitions of the loading spectrum, or the maximum strain level. The moisture conditioning reduced the residual strengths of the S-glass buffer strip panel by 10 to 15 percent below the ambient results. The moisture conditioning did not have a large effect on the Kevlar-49 panels.

  2. Thermally induced vibrations of smart solar panel in a low-orbit satellite

    Science.gov (United States)

    Azadi, E.; Fazelzadeh, S. Ahmad; Azadi, M.

    2017-03-01

    In this paper, a smart flexible satellite moving in a circular orbit with two flexible panels are studied. The panels have been modeled as clamped-free-free-free rectangular plates with attached piezoelectric actuators. It is assumed that the satellite has a pitch angle rotation maneuver. Rapid temperature changes at day-night transitions in orbit generate time dependent bending moments. Satellite maneuver and temperature varying induce vibrations in the appendages. So, to simulate the system, heat radiation effects on the appendages have been considered. The nonlinear equations of motion and the heat transfer equations are coupled and solved simultaneously. So, the governing equations of motion are nonlinear and very complicated ones. Finally, the whole system is simulated and the effects of the heat radiation, radius of the orbit, piezoelectric voltages, and piezoelectric locations on the response of the system are studied.

  3. Fracture Mechanics Analyses of the Slip-Side Joggle Regions of Wing-Leading-Edge Panels

    Science.gov (United States)

    Raju, Ivatury S.; Knight, Norman F., Jr.; Song, Kyongchan; Phillips, Dawn R.

    2011-01-01

    The Space Shuttle wing-leading edge consists of panels that are made of reinforced carbon-carbon. Coating spallation was observed near the slip-side region of the panels that experience extreme heating. To understand this phenomenon, a root-cause investigation was conducted. As part of that investigation, fracture mechanics analyses of the slip-side joggle regions of the hot panels were conducted. This paper presents an overview of the fracture mechanics analyses.

  4. Passive heating following the prematch warm-up in soccer: examining the time-course of changes in muscle temperature and contractile function.

    Science.gov (United States)

    Marshall, Paul W M; Cross, Rebecca; Lovell, Ric

    2015-12-01

    This study examined changes in muscle temperature, electrically evoked muscle contractile properties, and voluntary power before and after a soccer specific active warm-up and subsequent rest period. Ten amateur soccer players performed two experimental sessions that involved performance of a modified FIFA 11+ soccer specific warm-up, followed by a 12.5-min rest period where participants were required to wear either normal clothing or a passive electrical heating garment was applied to the upper thigh muscles. Assessments around the warm-up and cool-down included measures of maximal torque, rate of torque development, muscle temperature (Tm), and electrically evoked measures of quadriceps contractile function. Tm was increased after the warm-up by 3.2 ± 0.7°C (P warm-up between 20% and 30% (P warm-up did not effect variables measured. While Tm was reduced by 1.4 ± 0.4°C after the rest period (P warm-up levels. Voluntary and evoked rate of torque development remained elevated from pre warm-up levels at the end of the cool-down (P warm-up elevated muscle temperature by 3.2°C and was associated with concomitant increases of between 20% and 30% in voluntary rate of torque development, which seems explained by elevations in rate-dependent measures of intrinsic muscle contractile function. Application of a passive heating garment did not attenuate declines in muscle temperature during a 12.5-min rest period. © 2015 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  5. Numerical modelling and experimental studies of thermal behaviour of building integrated thermal energy storage unit in a form of a ceiling panel

    International Nuclear Information System (INIS)

    Jaworski, Maciej; Łapka, Piotr; Furmański, Piotr

    2014-01-01

    Highlights: • A new concept of heat storage in ventilation ducts is described. • Ceiling panel as a part of ventilation system is made of a composite with PCM. • A set-up for experimental investigation of heat storage unit was built. • Numerical model of heat transfer in the storage unit was developed. • Numerical code was validated on the base of experimental measurements. - Abstract: Objective: The paper presents a new concept of building integrated thermal energy storage unit and novel mathematical and numerical models of its operation. This building element is made of gypsum based composite with microencapsulated PCM. The proposed heat storage unit has a form of a ceiling panel with internal channels and is, by assumption, incorporated in a ventilation system. Its task is to reduce daily variations of ambient air temperature through the absorption (and subsequent release) of heat in PCM, without additional consumption of energy. Methods: The operation of the ceiling panel was investigated experimentally on a special set-up equipped with temperature sensors, air flow meter and air temperature control system. Mathematical and numerical models of heat transfer and fluid flow in the panel account for air flow in the panel as well as real thermal properties of the PCM composite, i.e.: thermal conductivity variation with temperature and hysteresis of enthalpy vs. temperature curves for heating and cooling. Proposed novel numerical simulator consists of two strongly coupled sub models: the first one – 1D – which deals with air flowing through the U-shaped channel and the second one – 3D – which deals with heat transfer in the body of the panel. Results: Spatial and temporal air temperature variations, measured on the experimental set-up, were used to validate numerical model as well as to get knowledge of thermal performance of the panel operating in different conditions. Conclusion: Preliminary results of experimental tests confirmed the ability of

  6. The Improvement of Thermal Insulating Concrete Panel

    Directory of Open Access Journals (Sweden)

    Mohammed Ali Nasser Ali

    2018-05-01

    Full Text Available The Iraqi houses flattening the roof by a concrete panel, and because of the panels on the top directly exposed to the solar radiation become unbearably hot and cold during the summer and winter. The traditional concrete panel components are cement, sand, and aggregate, which have a poor thermal property. The usage of materials with low thermal conductivity with no negative reflects on its mechanical properties gives good improvements to the thermal properties of the concrete panel. The practical part of this work was built on a multi-stage mixing plan. In the first stage the mixing ratio based on the ratios of the sand to cement. The second stage mixing ratios based on replacing the coarse aggregate quantities with the Alabaster aggregates, and the third stage the mixing ratios based on the replacement of wood ash instead of the sand. While the fourth stage mixing ratios based on decreasing the thermal conductivity and increasing mechanical properties by adding a multilayer of a plastic net. The result shows that using a concrete panel with components (cement, sand, coarse aggregate, wood ash, and Alabaster aggregates with a mass ratio of (1:1:2:1:1 and 3-plastic layers, gives the best improvement of the thermal properties. Where, the thermal conductivity is reduced by 42% and the specific heat increased by 41.2% as compared to the traditional concrete panel mixing ratio, with mechanical properties are agreed with the Iraqi standards.

  7. 3D CFD simulations to study the effect of inclination of condenser tube on natural convection and thermal stratification in a passive decay heat removal system

    Energy Technology Data Exchange (ETDEWEB)

    Minocha, Nitin [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400 094 (India); Joshi, Jyeshtharaj B., E-mail: jbjoshi@gmail.com [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400 094 (India); Department of Chemical Engineering, Institute of Chemical Technology, Matunga, Mumbai 400 019 (India); Nayak, Arun K. [Reactor Engineering Division, Bhabha Atomic Research Center, Trombay, Mumbai 400 085 (India); Vijayan, Pallippattu K., E-mail: vijayanp@barc.gov.in [Reactor Engineering Division, Bhabha Atomic Research Center, Trombay, Mumbai 400 085 (India)

    2016-08-15

    Highlights: • Investigation of three-dimensional natural convection and thermal stratification inside large water pool. • Effect of inclination (α) of condenser tube on fluid flow and heat transfer. • The heat transfer was found to be maximum for α = 90° and minimum for α = 15°. • Laminar-turbulent natural convection and heat transfer in the presence of longitudinal vortices. - Abstract: Many advanced nuclear reactors adopt methodologies of passive safety systems based on natural forces such as gravity. In one of such system, the decay heat generated from a reactor is removed by isolation condenser (ICs) submerged in a large water pool called the Gravity Driven Water Pool (GDWP). The objective of the present study was to design an IC for the passive decay heat removal system (PDHRS) for advanced nuclear reactor. First, the effect of inclination of IC tube on three dimensional temperature and flow fields was investigated inside a pilot scale (10 L) GDWP. Further, the knowledge of these fields has been used for the quantification of heat transfer and thermal stratification phenomenon. In a next step, the knowledge gained from the pilot scale GDWP has been extended to design an IC for real size GDWP (∼10,000 m{sup 3}). Single phase CFD simulation using open source CFD code [OpenFOAM-2.2] was performed for different tube inclination angles (α) (w.r.t. to vertical direction) in the range 0° ⩽ α ⩽ 90°. The results indicate that the heat transfer coefficient increases with increase in tube inclination angle. The heat transfer was found to be maximum for α = 90° and minimum for α = 15°. This behavior is due to the interaction between the primary flow (due to pressure gradient) and secondary flow (due to buoyancy force). The primary flow enhanced the fluid sliding motion at the tube top whereas the secondary flow resulted in enhancement in fluid motion along the circumference of tube. As the angle of inclination (α) of the tube was increased, the

  8. Minimum weight passive insulation requirements for hypersonic cruise vehicles.

    Science.gov (United States)

    Ardema, M. D.

    1972-01-01

    Analytical solutions are derived for two representative cases of the transient heat conduction equation to determine the minimum weight requirements for passive insulation systems of hypersonic cruise vehicles. The cases discussed are the wet wall case with the interior wall temperature held to that of the boiling point of the fuel throughout the flight, and the dry wall case where the heat transferred through the insulation is absorbed by the interior structure whose temperature is allowed to rise.

  9. Development and first experimental results of the KERENA Passive Outflow Reducer

    Energy Technology Data Exchange (ETDEWEB)

    Dumond, Julien; Maisberger, Fabian [AREVA NP GmbH (Germany); Class, Andreas [Karlsruher Institut fuer Technologie (Germany)

    2012-11-01

    Increased safety and reduced costs are achieved in the boiling water reactor KERENA with a smart combination of active and passive safety systems. One of these passive systems is the Emergency Condenser (EC). The EC passively removes excess heat and in particular the decay heat from the Reactor Pressure Vessel (RPV) during transients and Loss of Coolant Accidents (LOCA) without supplementary water inventory loss. The EC passively becomes active when the water level in the condenser tubes falls so that steam gets in contact with the cold condenser surface. This is triggered by a transient or a loss of coolant involving drop in RPV water level. The condensate returns to the RPV through the EC condensate return line. A break of the EC return line must be considered as a design accident. The Passive Outflow Reducer (POR) is positioned in the reactor nozzle at the end of the EC condensate return line to limit the loss of coolant passively without moving part in this scenario before other passive and active systems fill up the core with coolant. The requirements on the POR are conflicting. On the one hand, the mass flow leaving the RPV has to be limited in case of the break of the EC condensate return line. On the other hand, the flow resistance from the EC to the RPV should not decrease EC heat removal capacity. Furthermore, the component must be compact (l < 1m) and easily manufactured. In the framework of the PhD a new POR design composed of 37 parallel doublenozzle channels (Figure 1) has been developed. The development of this POR design is described in chapter 1. The system was first designed to meet LOCA requirement (section 1.1) in LOCA direction (red arrow on Figure 1) with system-code and then optimized to minimize flow resistance in EC direction (blue arrow on Figure 1) with commercial CFD software (section 1.2). Both requirements can be achieved with one single pipe but the component would be much too long (about 6 meters). To assure compactness of the

  10. Development and first experimental results of the KERENA Passive Outflow Reducer

    International Nuclear Information System (INIS)

    Dumond, Julien; Maisberger, Fabian; Class, Andreas

    2012-01-01

    Increased safety and reduced costs are achieved in the boiling water reactor KERENA with a smart combination of active and passive safety systems. One of these passive systems is the Emergency Condenser (EC). The EC passively removes excess heat and in particular the decay heat from the Reactor Pressure Vessel (RPV) during transients and Loss of Coolant Accidents (LOCA) without supplementary water inventory loss. The EC passively becomes active when the water level in the condenser tubes falls so that steam gets in contact with the cold condenser surface. This is triggered by a transient or a loss of coolant involving drop in RPV water level. The condensate returns to the RPV through the EC condensate return line. A break of the EC return line must be considered as a design accident. The Passive Outflow Reducer (POR) is positioned in the reactor nozzle at the end of the EC condensate return line to limit the loss of coolant passively without moving part in this scenario before other passive and active systems fill up the core with coolant. The requirements on the POR are conflicting. On the one hand, the mass flow leaving the RPV has to be limited in case of the break of the EC condensate return line. On the other hand, the flow resistance from the EC to the RPV should not decrease EC heat removal capacity. Furthermore, the component must be compact (l < 1m) and easily manufactured. In the framework of the PhD a new POR design composed of 37 parallel doublenozzle channels (Figure 1) has been developed. The development of this POR design is described in chapter 1. The system was first designed to meet LOCA requirement (section 1.1) in LOCA direction (red arrow on Figure 1) with system-code and then optimized to minimize flow resistance in EC direction (blue arrow on Figure 1) with commercial CFD software (section 1.2). Both requirements can be achieved with one single pipe but the component would be much too long (about 6 meters). To assure compactness of the

  11. Activities of passive cooling applications and simulation of innovative nuclear power plant design

    International Nuclear Information System (INIS)

    Aglar, F.; Tanrykut, A.

    2002-01-01

    This paper gives a general insight on activities of the Turkish Atomic Energy Authority (TAEA) concerning passive cooling applications and simulation of innovative nuclear power plant design. The condensation mode of heat transfer plays an important role for the passive heat removal application in advanced water-cooled reactor systems. But it is well understood that the presence of noncondesable (NC) gases can greatly inhibit the condensation process due to the build up of NC gas concentration at the liquid/gas interface. The isolation condenser of passive containment cooling system of the simplified boiling water reactors is a typical application area of in-tube condensation in the presence of NC. The test matrix of the experimental investigation undertaken at the METU-CTF test facility (Middle East Technical University, Ankara) covers the range of parameters; Pn (system pressure) : 2-6 bar, Rev (vapor Reynolds number): 45,000-94,000, and Xi (air mass fraction): 0-52%. This experimental study is supplemented by a theoretical investigation concerning the effect of mixture flow rate on film turbulence and air mass diffusion concepts. Recently, TAEA participated to an international standard problem (OECD ISP-42) which covers a set of simulation of PANDA test facility (Paul Scherrer Institut-Switzerland) for six different phases including different natural circulation modes. The concept of condensation in the presence of air plays an important role for performance of heat exchangers, designed for passive containment cooling, which in turn affect the natural circulation behaviour in PANDA systems. (author)

  12. Solar heating system

    Science.gov (United States)

    Schreyer, James M.; Dorsey, George F.

    1982-01-01

    An improved solar heating system in which the incident radiation of the sun is absorbed on collector panels, transferred to a storage unit and then distributed as heat for a building and the like. The improvement is obtained by utilizing a storage unit comprising separate compartments containing an array of materials having different melting points ranging from 75.degree. to 180.degree. F. The materials in the storage system are melted in accordance with the amount of heat absorbed from the sun and then transferred to the storage system. An efficient low volume storage system is provided by utilizing the latent heat of fusion of the materials as they change states in storing and releasing heat for distribution.

  13. Assessment of GOTHIC and TRACE codes against selected PANDA experiments on a Passive Containment Condenser

    Energy Technology Data Exchange (ETDEWEB)

    Papini, Davide, E-mail: davide.papini@psi.ch; Adamsson, Carl; Andreani, Michele; Prasser, Horst-Michael

    2014-10-15

    Highlights: • Code comparison on the performance of a Passive Containment Condenser. • Simulation of separate effect tests with pure steam and non-condensable gases. • Role of the secondary side and accuracy of pool boiling models are discussed. • GOTHIC and TRACE predict the experimental performance with slight underestimation. • Recirculatory flow pattern with injection of light non-condensable gas is inferred. - Abstract: Typical passive safety systems for ALWRs (Advanced Light Water Reactors) rely on the condensation of steam to remove the decay heat from the core or the containment. In the present paper the three-dimensional containment code GOTHIC and the one-dimensional system code TRACE are compared on the calculation of a variety of phenomena characterizing the response of a passive condenser submerged in a boiling pool. The investigation addresses the conditions of interest for the Passive Containment Cooling System (PCCS) proposed for the ESBWR (Economic Simplified Boiling Water Reactor). The analysis of selected separate effect tests carried out on a PCC (Passive Containment Condenser) unit in the PANDA large-scale thermal-hydraulic facility is presented to assess the code predictions. Both pure steam conditions (operating pressure of 3 bar, 6 bar and 9 bar) and the effect on the condensation heat transfer of non-condensable gases heavier than steam (air) and lighter than steam (helium) are considered. The role of the secondary side (pool side) heat transfer on the condenser performance is examined too. In general, this study shows that both the GOTHIC and TRACE codes are able to reasonably predict the heat transfer capability of the PCC as well as the influence of non-condensable gas on the system. A slight underestimation of the condenser performance is obtained with both codes. For those tests where the experimental and simulated efficiencies agree better the possibility of compensating errors among different parts of the heat transfer

  14. Pareto Optimization of a Half Car Passive Suspension Model Using a Novel Multiobjective Heat Transfer Search Algorithm

    Directory of Open Access Journals (Sweden)

    Vimal Savsani

    2017-01-01

    Full Text Available Most of the modern multiobjective optimization algorithms are based on the search technique of genetic algorithms; however the search techniques of other recently developed metaheuristics are emerging topics among researchers. This paper proposes a novel multiobjective optimization algorithm named multiobjective heat transfer search (MOHTS algorithm, which is based on the search technique of heat transfer search (HTS algorithm. MOHTS employs the elitist nondominated sorting and crowding distance approach of an elitist based nondominated sorting genetic algorithm-II (NSGA-II for obtaining different nondomination levels and to preserve the diversity among the optimal set of solutions, respectively. The capability in yielding a Pareto front as close as possible to the true Pareto front of MOHTS has been tested on the multiobjective optimization problem of the vehicle suspension design, which has a set of five second-order linear ordinary differential equations. Half car passive ride model with two different sets of five objectives is employed for optimizing the suspension parameters using MOHTS and NSGA-II. The optimization studies demonstrate that MOHTS achieves the better nondominated Pareto front with the widespread (diveresed set of optimal solutions as compared to NSGA-II, and further the comparison of the extreme points of the obtained Pareto front reveals the dominance of MOHTS over NSGA-II, multiobjective uniform diversity genetic algorithm (MUGA, and combined PSO-GA based MOEA.

  15. Experimental studies and economic considerations on a living space heated through passive solar gain and through electric power

    Directory of Open Access Journals (Sweden)

    Luminosu Iona

    2003-01-01

    Full Text Available The Trombe wall, of an area AT = 8.8 m, built on the southern facade of a room, heats the accommodation during the transition months, complementary to electric power. The statistical processing of the experimental data led to a global quantitative image of the wall’s behavior during the average day of the months March, April, September, and October 1999. The inner climate parameters are: tint = = 21 °C, trad = 17.9 °C, troom= 19.5 °C, j= 35-70%, E Î80 + 120 lx. The thermal comfort factor is B = -0.325. These values insure a room’s comfort close to the optimal one prescribed by the hygienists. The heliothermal conversion’s efficiency is hT = 10.4%. The proportion of heat supplied by the wall in the entire energy required by the room is hheat = 45.8%. The wall’s specific cost is Pu = 24.9 € /m. The write-off period of the initial investment is n = 53 years. The development of passive solar architecture in the Euro-region Danube-Cris-Mures-Tisa which includes the town of Timisoara (45° north, 22° east, was proven feasible by the experiments from both the energy and the economical point of view.

  16. Active and passive beam application design guide for global application

    CERN Document Server

    Rimmer, Julian

    2015-01-01

    The Active and Passive Beam Application Design Guide is the result of collaboration by worldwide experts to give system designers a current, authoritative guide on successfully applying active and passive beam technology. Active and Passive Beam Application Design Guide provide energy-efficient methods of cooling, heating, and ventilating indoor areas, especially spaces that require individual zone control and where internal moisture loads are moderate. The systems are simple to operate, with low maintenance requirements. This book is an essential resource for consulting engineers, architects, owners, and contractors who are involved in the design, operation, and installation of these systems. Building on REHVA’s Chilled Beam Application Guidebook, this new guide provides up-to-date tools and advice for designing, commissioning, and operating chilled-beam systems to achieve a determined indoor climate, and includes examples of active and passive beam calculations and selections. Dual units (SI and I-P) are...

  17. Radiation Heat Transfer Effect on Thermal Sizing of Air-Cooling Heat Exchanger of Emergency Cooldown Tank

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Joo Hyung; Kim, Young In; Kim, Keung Koo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Myoung Jun; Lee, Hee Joon [School of Mechanical Eng., Kookmin University, Seoul (Korea, Republic of)

    2014-10-15

    An attempt has begun to extend the life time of emergency cooldown tank (ECT) by Korea Atomic Energy Research Institute (KAERI) researchers. Moon et al. recently reported a basic concept upon how to keep the ECT in operation beyond 72 hours after an accident occurs without any active corrective actions for the postulated design basis accidents. When the SMART (System-integrated Modular Advanced Reac-Tor) received its Standard Design Approval (SDA) for the first time in the world, hybrid safety systems are applied. However, the passive safety systems of SMART are being enforced in response to the public concern for much safer reactors since the Fukushima accident occurred. The ECT is a major component of a passive residual heat removal system (PRHRS), which is one of the most important systems to enhance the safety of SMART. It is being developed in a SMART safety enhancement project to contain enough cooling water to remove a sensible heat and a decay heat from reactor core for 72 hours since an accident occurs. Moon et al. offered to install another heat exchanger above the ECT and to recirculate an evaporated steam into water, which enables the ECT to be in operation, theoretically, indefinitely. An investigation was made to determine how long and how many tubes were required to meet the purpose of the study. In their calculation, however, a radiation heat transfer effect was neglected. The present study is to consider the radiation heat transfer for the design of air-cooling heat exchanger. Radiation heat transfer is normally ignored in many situations, but this is not the case for the present study. Kim et al. conducted thermal sizing of scaled-down ECT heat exchanger, which will be used to validate experimentally the basic concept of the present study. Their calculation is also examined to see if a radiation heat transfer effect was taken into consideration. The thermal sizing of an air-cooling heat exchanger was conducted including radiation heat transfer

  18. A Passive, Adaptive and Autonomous Gas Gap Heat Switch

    NARCIS (Netherlands)

    Vanapalli, Srinivas; Colijn, B.A.; Vermeer, Cristian Hendrik; Holland, Herman J.; Tirolien, T.; ter Brake, Hermanus J.M.

    2015-01-01

    We report on the development of a heat switch for autonomous temperature control of electronic components in a satellite. A heat switch can modulate when needed between roles of a good thermal conductor and a good thermal insulator. Electronic boxes on a satellite should be maintained within a

  19. Computational estimation of decline in sweating in the elderly from measured body temperatures and sweating for passive heat exposure

    International Nuclear Information System (INIS)

    Hirata, Akimasa; Nomura, Tomoki; Laakso, Ilkka

    2012-01-01

    Several studies reported the difference in heat tolerance between younger and older adults, which may be attributable to the decline in the sweating rate. One of the studies suggested a hypothesis that the dominant factor causing the decline in sweating was the decline in thermal sensitivity due to a weaker signal from the periphery to the regulatory centres. However, no quantitative investigation of the skin temperature threshold for activating the sweating has been conducted in previous studies. In this study, we developed a computational code to simulate the time evolution of the temperature variation and sweating in realistic human models under heat exposure, in part by comparing the computational results with measured data from younger and older adults. Based on our computational results, the difference in the threshold temperatures for activating the thermophysiological response, especially for sweating, is examined between older and younger adults. The threshold for activating sweating in older individuals was found to be about 1.5 °C higher than that in younger individuals. However, our computation did not suggest that it was possible to evaluate the central alteration with ageing by comparing the computation with the measurements for passive heat exposure, since the sweating rate is marginally affected by core temperature elevation at least for the scenarios considered here. The computational technique developed herein is useful for understanding the thermophysiological response of older individuals from measured data. (note)

  20. Evaluation of the reliability of a passive system

    International Nuclear Information System (INIS)

    Bianchi, F.; Burgazzi, L.; D'Auria, F.; Galassi, G.M.; Ricotti, M.E.; Oriani, L.

    2001-01-01

    A passive system should be theoretically more reliable than an active one. In fact its operation is independent by any external input or energy and is relied only upon natural physical laws (e.g., gravity, natural circulation, etc.) and/or 'intelligent' use of the energy inherently available in the system (e.g., chemical reaction, decay heat, etc.). Nevertheless the passive system may fail its mission as consequences of component failures, deviation of physical phenomena, boundary and/or initial conditions from the expectation. This document describes at first the methodology developed by ENEA, in collaboration of University of Pisa and Polytechnic of Milano, allowing the evaluation of the reliability for a passive system, which operation is based on moving working fluids (type B and C, cf. IAEA). It reports the results of an exercise performed on a system, which operation is based on Natural Circulation.(author)

  1. The research activities on in-tube condensation in the presence of noncondensables for passive cooling applications

    Energy Technology Data Exchange (ETDEWEB)

    Tanrikut, A [Turkish Atomic Energy Authority, Ankara (Turkey)

    1996-12-01

    The introduction of nuclear power becomes an attractive solution to the problem of increasing demand for electricity power capacity in Turkey. Thus, Turkey is willing to follow the technological development trends in advanced reactor systems and to participate in joint research studies. The primary objectives of the passive design features are to simplify the design, which assures the minimized demand on operator, and to improve plant safety. To accomplish these features the operating principles of passive safety systems should be well understood by an experimental validation program. Such a validation program is also important for the assessment of advanced computer codes which are currently used for design and licensing procedures. The condensation mode of heat transfer plays an important role for the passive heat removal applications in the current nuclear power plants (e.g. decay heat removal via steam generators in case of loss of heat removal system) and advanced water-cooled reactor systems. But is well established that the presence of noncondensable gases can greatly inhibit the condensation process due to the build-up of noncondensable gas concentration at the liquid/gas interface. The isolation condenser of passive containment cooling system of the simplified boiling water reactors is a typical application area of in-tube condensation in the presence of noncondensable. This paper describes the research activities at the Turkish Atomic Energy Authority concerning condensation in the presence of air, as a noncondensable gas. (author). 9 refs, 6 figs.

  2. The research activities on in-tube condensation in the presence of noncondensables for passive cooling applications

    International Nuclear Information System (INIS)

    Tanrikut, A.

    1996-01-01

    The introduction of nuclear power becomes an attractive solution to the problem of increasing demand for electricity power capacity in Turkey. Thus, Turkey is willing to follow the technological development trends in advanced reactor systems and to participate in joint research studies. The primary objectives of the passive design features are to simplify the design, which assures the minimized demand on operator, and to improve plant safety. To accomplish these features the operating principles of passive safety systems should be well understood by an experimental validation program. Such a validation program is also important for the assessment of advanced computer codes which are currently used for design and licensing procedures. The condensation mode of heat transfer plays an important role for the passive heat removal applications in the current nuclear power plants (e.g. decay heat removal via steam generators in case of loss of heat removal system) and advanced water-cooled reactor systems. But is well established that the presence of noncondensable gases can greatly inhibit the condensation process due to the build-up of noncondensable gas concentration at the liquid/gas interface. The isolation condenser of passive containment cooling system of the simplified boiling water reactors is a typical application area of in-tube condensation in the presence of noncondensable. This paper describes the research activities at the Turkish Atomic Energy Authority concerning condensation in the presence of air, as a noncondensable gas. (author). 9 refs, 6 figs

  3. Development of Amorphous/Microcrystalline Silicon Tandem Thin-Film Solar Modules with Low Output Voltage, High Energy Yield, Low Light-Induced Degradation, and High Damp-Heat Reliability

    Directory of Open Access Journals (Sweden)

    Chin-Yi Tsai

    2014-01-01

    Full Text Available In this work, tandem amorphous/microcrystalline silicon thin-film solar modules with low output voltage, high energy yield, low light-induced degradation, and high damp-heat reliability were successfully designed and developed. Several key technologies of passivation, transparent-conducting-oxide films, and cell and segment laser scribing were researched, developed, and introduced into the production line to enhance the performance of these low-voltage modules. A 900 kWp photovoltaic system with these low-voltage panels was installed and its performance ratio has been simulated and projected to be 92.1%, which is 20% more than the crystalline silicon and CdTe counterparts.

  4. Development of climatic zones and passive solar design in Madagascar

    International Nuclear Information System (INIS)

    Rakoto-Joseph, O.; Garde, F.; David, M.; Adelard, L.; Randriamanantany, Z.A.

    2009-01-01

    Climate classification is extremely useful to design buildings for thermal comfort purposes. This paper presents the first work for a climate classification of Madagascar Island. This classification is based on the meteorological data measured in different cities of this country. Three major climatic zones are identified. Psychometric charts for the six urban areas of Madagascar are proposed, and suited passive solar designs related to each climate are briefly discussed. Finally, a total of three passive design zones have been identified and appropriate design strategies such as solar heating, natural ventilation, thermal mass are suggested for each zone. The specificity of this work is that: it is the first published survey on the climate classification and the passive solar designs for this developing country

  5. FLOW DISTRIBUTION IN A SOLAR COLLECTOR PANEL WITH HORIZONTAL ABSORBER STRIPS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    2007-01-01

    The objective of this work is to theoretically and experimentally investigate the flow and temperature distribution in a solar collector panel with an absorber consisting of horizontal strips. Fluid flow and heat transfer in the collector panel are studied by means of computational fluid dynamics...... (CFD) calculations. Further, experimental investigations of a 12.5 m² solar collector panel with 16 parallel connected horizontal fins are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the backside of the absorber tubes. The measured...... collector fluid, and by increased collector tilt and inlet temperature, the flow distribution gets worse resulting in a decreased collector efficiency and an increased risk of boiling in the upper part of the collector panel. Keywords: Solar collector; Flow distribution; Computational Fluid Dynamics (CFD...

  6. Shielding behavior of multi-transformation phase change materials (MTPCM) against nuclear radiations

    International Nuclear Information System (INIS)

    Kumar, Ravindra; Goplani, Deepak; Kumar, Rohitash; Das, Mrinal Kumar; Kumar, Pramod; Jodha, Ajay Singh; Misra, Manoj; Khatri, P.K.

    2008-01-01

    In nuclear hardened structures and AFV's, special shielding materials are being used to provide protection from radiations generated in nuclear blast. However, in blast an intense heat pulse is also generated along with radiation. Currently used shield does not take care of this heat pulse. Defence Laboratory, Jodhpur has developed multi transformation phase change materials (MTPCM) based cool panels for passive moderation of temperature in severe desert heat. The MTPCM contains light nuclei of hydrogen, carbon and oxygen, and thus can absorb good amount of neutrons. MTPCM can also absorb intense heat pulse along with heat generated by secondary fires during blast as its latent heat (160-170 J/g) without significant rise in temperature (melting point 36-38 deg. C). Thus MTPCM can provide protection against both radiation as well as heat pulse generated in a nuclear blast along with its designed regular function of passively moderating temperature below 40 deg C during severe desert summer. A study has been undertaken to explore multiple applications of MTPCM panel. Protection factor provided by standard MTPCM panels against neutron and gamma radiations (both initial and fall out) were measured and results compared with PF provided by special lining pad currently being used in AFV's and field structures for nuclear protection. It is observed that MTPCM provides good PF (2.17) against neutron which is better than currently used shield pads (PFP%1.8). Present paper discusses results of this study. (author)

  7. An experimental study on natural draft-dry cooling tower as part of the passive system for the residual decay heat removal

    International Nuclear Information System (INIS)

    Caruso, G.; Fatone, M.; Naviglio, A.

    2007-01-01

    An experimental apparatus has been built in order to perform sensitivity analysis on the performance of a natural draft-dry cooling tower. This component plays an important role in the passive system for the residual heat decay removal foreseen in the MARS reactor and in the GCFR of the Generation IV reactors. The sensitivity analysis has investigated: 1) the heat exchanger arrangement; two different arrangements have been considered: a horizontal arrangement, in which a system of electrical heaters are placed at the inlet cross section of the tower, and a vertical arrangement, with the heaters distributed vertically around the circumference of the tower. 2) The shape of the cooling tower; by varying the angle of the shell inclination it is possible to obtain a different shape for the tower itself. An upper and a lower angle inclination were modified and by a calculation procedure eleven different configuration were selected. 3) The effect of cross wind on the tower performance. An equation-based procedure to design the dry-cooling tower is presented. In order to evaluate the influence of the shape and the heat exchanger arrangement on the performance of the cooling tower, a geometrical factor (FG) and a thermal factor (FT) are introduced. By analyzing the experimental results, engineering design relations are obtained to model the cooling tower performance. The comparison between the experimental heat transfer coefficient and the heat transfer coefficient obtained by the mathematical procedure shows that there is a good agreement. The obtained results show that it is possible to evaluate the shape and the heat exchanger arrangement to optimize the performance of the cooling tower either in wind-less condition either in presence of cross wind. (authors)

  8. Heat transfer and loss by whole-body hyperthermia during severe lower-body heating are impaired in healthy older men.

    Science.gov (United States)

    Brazaitis, Marius; Paulauskas, Henrikas; Eimantas, Nerijus; Obelieniene, Diana; Baranauskiene, Neringa; Skurvydas, Albertas

    2017-10-01

    Most studies demonstrate that aging is associated with a weakened thermoregulation. However, it remains unclear whether heat transfer (for heat loss) from the lower (uncompensable) to the upper (compensable) body during passively-induced severe lower-body heating is delayed or attenuated with aging. Therefore, the main purpose of this study was to investigate heat transfer from uncompensable to compensable body areas in young men and healthy older men during passively-induced whole-body hyperthermia with a demonstrated post-heating change in core body (rectal; T re ) temperature. Nine healthy older men and eleven healthy young men (69±6 vs. 21±1 years old, mean±SD, Pheating in water at approximately 43°C. Despite a similar increment in T re (approximately 2.5°C) in both groups, the heating rate was significantly lower in older men than in young men (1.69±0.12 vs. 2.47±0.29°C/h, respectively; Pheat in the skin and deep muscles than young men, and this was associated with a greater heat-transfer delay and subsequent inertia in the increased core body (T re ) temperature. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Fluid flow in panel radiator under various conditions - thermographic visualisation

    Directory of Open Access Journals (Sweden)

    Bašta Jiří

    2012-04-01

    Full Text Available Thermographic investigation of a heating panel radiator under various conditions, especially with various heating water volume flow rate is described in this article. For a radiator type 10-500x1000 TBOE and for two levels of inlet water temperature (75 and 55 °C a set of thermal images of surface temperature patterns for various values of heating water volume flow rate was taken. The initial value of flow rate was derived from nominal heating output and recalculated to real conditions. An increase of volume flow rate higher than 15 % over the nominal recalculated value is for the studied cases easily detectable on the resulting thermal images.

  10. Improving the efficiency of photovoltaic (PV) panels by oil coating

    International Nuclear Information System (INIS)

    Abd-Elhady, M.S.; Fouad, M.M.; Khalil, T.

    2016-01-01

    Highlights: • It is possible to improve the efficiency of PV panels by increasing the amount of light transmitted to the panel. • Coating PV panels by a fine layer of Labovac oil increases the amount of sun light transmitted to the panel. • Coating PV panels by a fine layer of Labovac oil increases the power output of the panel. • Coating PV panels with a layer of Labovac oil has to be applied in cold countries and not in hot regions. - Abstract: The objective of this research is to develop a new technique for improving the efficiency of Photovoltaic (PV) panels. This technique is done by coating the front surface of the PV panel by a fine layer of oil in order to increase the amount of light transmitted to the panel, and consequently its efficiency. Different types of oils are examined, including both mineral oils and natural oils. In case of mineral oils; vacuum pump oil (Labovac oil), engine oil (Mobil oil) and brake oil (Abro oil) are examined, while in case of natural oils; olive and sunflower oils are examined. An experimental setup has been developed to examine the performance of the PV panels as a function of oil coatings. The experimental setup consists of an artificial sun, the PV panel under investigation, a cooling system and a measuring system to measure the performance of the panel. It has been found that coating the PV panel with a fine layer of Labovac oil, ∼1 mm thick, improves the efficiency of the PV panel by more than 20%, and this is due to the high transmissivity of the Labovac oil compared to other oils. However, the Labovac oil has a drawback which is overheating of the panel due to its high transmissivity. Coating of PV panels with a fine layer of Labovac oil should be done only in cold regions, in order to avoid the heating effect that can decrease the power output of PV panels.

  11. Heat transfer characteristics and operation limit of pressurized hybrid heat pipe for small modular reactors

    International Nuclear Information System (INIS)

    Kim, Kyung Mo; Bang, In Cheol

    2017-01-01

    Highlights: • Thermal performances and operation limits of hybrid heat pipe were experimentally studied. • Models for predicting the operation limit of the hybrid heat pipe was developed. • Non-condensable gas affected heat transfer characteristics of the hybrid heat pipe. - Abstract: In this paper, a hybrid heat pipe is proposed for use in advanced nuclear power plants as a passive heat transfer device. The hybrid heat pipe combines the functions of a heat pipe and a control rod to simultaneously remove the decay heat generated from the core and shutdown the reactor under accident conditions. Thus, the hybrid heat pipe contains a neutron absorber in the evaporator section, which corresponds to the core of the reactor pressure vessel. The presence of the neutron absorber material leads to differences in the heated diameter and hydraulic diameter of the heat pipe. The cross-sectional areas of the vapor paths through the evaporator, adiabatic, and condenser sections are also different. The hybrid heat pipe must operate in a high-temperature, high-pressure environment to remove the decay heat. In other words, the operating pressure must be higher than those of the commercially available thermosyphons. Hence, the thermal performances, including operation limit of the hybrid heat pipe, were experimentally studied in the operating pressure range of 0.2–20 bar. The operating pressure of the hybrid heat pipe was controlled by charging the non-condensable gas which is unused method to achieve the high saturation pressure in conventional thermosyphons. The effect of operating pressure on evaporation heat transfer was negligible, while condensation heat transfer was affected by the amount of non-condensable gas in the test section. The operation limit of the hybrid heat pipe increased with the operating pressure. Maximum heat removal capacity of the hybrid heat pipe was up to 6 kW which is meaningful value as a passive decay heat removal device in the nuclear power

  12. Issues and approaches in risk-based aging analyses of passive components

    International Nuclear Information System (INIS)

    Uryasev, S.P.; Samanta, P.K.; Vesely, W.E.

    1994-01-01

    In previous NRC-sponsored work a general methodology was developed to quantify the risk contributions from aging components at nuclear plants. The methodology allowed Probabilistic Risk Analyses (PRAs) to be modified to incorporate the age-dependent component failure rates and also aging maintenance models to evaluate and prioritize the aging contributions from active components using the linear aging failure rate model and empirical components aging rates. In the present paper, this methodology is extended to passive components (for example, the pipes, heat exchangers, and the vessel). The analyses of passive components bring in issues different from active components. Here, we specifically focus on three aspects that need to be addressed in risk-based aging prioritization of passive components

  13. Energy efficient heating and ventilation of large halls

    CERN Document Server

    Hojer, Ondrej; Kabele, Karel; Kotrbaty, Miroslav; Sommer, Klaus; Petras, Dusan

    2011-01-01

    This guidebook is focused on modern methods for design, control and operation of energy efficient heating systems in large spaces and industrial halls. The book deals with thermal comfort, light and dark gas radiant heaters, panel radiant heating, floor heating and industrial air heating systems. Various heating systems are illustrated with case studies. Design principles, methods and modeling tools are presented for various systems.

  14. Simulation of an active solar energy system integrated in a passive building in order to obtain system efficiency

    Science.gov (United States)

    Ceacaru, Mihai C.

    2012-11-01

    In this work we present a simulation of an active solar energy system. This system belongs to the first passive office building (2086 square meters) in Romania and it is used for water heating consumption. This office building was opened in February 2009 and was built based on passive house design solutions. For this simulation, we use Solar Water Heating module, which belongs to the software RETSCREEN and this simulation is done for several cities in Romania. Results obtained will be compared graphically.

  15. Passive solar design strategies: Remodeling guidelines for conserving energy at home

    Science.gov (United States)

    The idea of passive solar is simple, but applying it effectively does require information and attention to the details of design and construction. Some passive solar techniques are modest and low-cost, and require only small changes in remodeler's typical practice. At the other end of the spectrum, some passive solar systems can almost eliminate a house's need for purchased heating (and in some cases, cooling) energy - but probably at a relatively high first cost. In between are a broad range of energy-conserving passive solar techniques. Whether or not they are cost-effective, practical, and attractive enough to offer a market advantage to any individual remodeler depends on very specific factors such as local costs, climate, and market characteristics. Passive Solar Design Strategies: Remodeling Guidelines For Conserving Energy At Home is written to help give remodelers the information they need to make these decisions. Passive Solar Design Strategies is a package in three basic parts: the guidelines contain information about passive solar techniques and how they work, and provides specific examples of systems which will save various percentages of energy; the worksheets offer a simple, fill-in-the-blank method to pre-evaluate the performance of a specific design; and the worked example demonstrates how to complete the worksheets for a typical residence.

  16. In Middle Europe, heating of an industrial building only with solar energy. First solar house industrial building with passive house standard in this size; In Mitteleuropa ein Industriegebaeude nur mit der Sonne heizen. Erstes Sonnenhaus Industriegebaeude mit Passivhaus-Standard in dieser Groesse

    Energy Technology Data Exchange (ETDEWEB)

    Huemer, Herbert [Xolar Renewable Energy Group HQ, Eberstalzell (Austria)

    2010-07-01

    Since 2008, Xolar Renewable Energy Group (Eberstalzell, Austria) combines the companies Sunmaster and Xolar in the most modern solar house in Europe with passive house standard. The contribution under consideration reports on the development of an industrial building which is heated entirely by solar energy and meets the standards of passive houses. All working places in the building should be sunny and free of draught. It does not use electrically powered heat pumps or refrigerators. All energy values calculated by simulation were achieved or partly exceeded. The savings in annual operating costs compared to conventional construction in factory buildings is approximately 192,000 Euro per year.

  17. Preliminary Study of Applying Phase Change Materials (PCM) for Containment Passive Cooling

    International Nuclear Information System (INIS)

    Ko, A Reum; Lee, Jeong Ik; Yoon, Ho Joon

    2016-01-01

    Most of Pressurized Water Reactor (PWR) containments use fan cooler systems and containment spray systems. However, the importance of passive safety system has increased after the Fukushima accident. As the main passive safety system, Passive Containment Cooling System (PCCS), which utilizes natural phenomena to remove the heat released from the reactor, is suggested in the advanced pressurized water reactor (APWR). To increase the efficiency of passive cooling, additional passive containment cooling method using Phase Change Material (PCM) is suggested in this paper. For containment using PCMs, there are many advantages. Phase Change Material (PCM) is proposed as an additional passive containment cooling method to increase the efficiency of passive cooling in this paper. To apply proper PCMs to containment, commercially available PCMs were screened while reviewing thermophysical properties data and suggested selection criteria. A sensitivity study was also carried out to identify the effect of potential installation location of PCM using the CAP code. The pressure of containment in most cases showed slightly higher than that of the initial case. For the temperature of steam and water and humidity, similar results with the initial case were showed in most cases

  18. Preliminary Study of Applying Phase Change Materials (PCM) for Containment Passive Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Ko, A Reum; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of); Yoon, Ho Joon [KUSTAR, Abu Dhabi (United Arab Emirates)

    2016-05-15

    Most of Pressurized Water Reactor (PWR) containments use fan cooler systems and containment spray systems. However, the importance of passive safety system has increased after the Fukushima accident. As the main passive safety system, Passive Containment Cooling System (PCCS), which utilizes natural phenomena to remove the heat released from the reactor, is suggested in the advanced pressurized water reactor (APWR). To increase the efficiency of passive cooling, additional passive containment cooling method using Phase Change Material (PCM) is suggested in this paper. For containment using PCMs, there are many advantages. Phase Change Material (PCM) is proposed as an additional passive containment cooling method to increase the efficiency of passive cooling in this paper. To apply proper PCMs to containment, commercially available PCMs were screened while reviewing thermophysical properties data and suggested selection criteria. A sensitivity study was also carried out to identify the effect of potential installation location of PCM using the CAP code. The pressure of containment in most cases showed slightly higher than that of the initial case. For the temperature of steam and water and humidity, similar results with the initial case were showed in most cases.

  19. Westinghouse-GOTHIC comparisons to AP600 passive containment cooling tests

    International Nuclear Information System (INIS)

    Kennedy, M.D.; Woodcock, J.; Gresham, J.A.

    1994-01-01

    Westinghouse-GOTHIC is a thermal-hydraulics code well suited to analyzing passively cooled containments which depend on heat removal primarily through the containment shell. The code includes boundary layer heat and mass transfer correlations. A liquid film convective energy transport model has been added to the Westinghouse-GOTHIC code to account for the sensible heat change of the applied exterior water. The objective of this paper is to compare the code's predictions of the AP600 large scale test facility with and without the liquid film convective energy transport model. The predicted vessel pressure and integrated heat rate with and without the film convective energy transport model will be compared to the measured data. (author)

  20. Development of passive design zones in China using bioclimatic approach

    International Nuclear Information System (INIS)

    Lam, Joseph C.; Yang Liu; Liu Jiaping

    2006-01-01

    This paper presents the work on development of passive design zones for different climates in China. A total of 18 cities representing the five major climatic types, namely severe cold, cold, hot summer and cold winter, mild and hot summer and warm winter were selected for climatic analysis. Measured weather data were gathered and analysed. A bioclimatic approach was adopted in which the comfort zone and 12 monthly climatic lines were determined and plotted on the psychrometric chart for each city. From these bioclimatic charts, the potential use of passive design strategies such as solar heating, natural ventilation, thermal mass with/without night ventilation and evaporative cooling was assessed. A total of nine passive design strategy zones were identified, and appropriate design strategies suggested for both summer and winter consideration

  1. Effects of the Solid Solution Heat Treatment on the Corrosion Resistance Property of SSC13 Cast Alloy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kuk-Jin [Hi-Sten Co., Ltd., Gimhae (Korea, Republic of); Lim, Su Gun [Gyeongsang National University, Jinju (Korea, Republic of); Pak, S. J. [Gachon BioNano Research Institute, Gachon University, Sungnam (Korea, Republic of)

    2015-04-15

    Recently, Stainless steels have been increasingly selected as the fitting or the valve materials of water pipes as the human health issue is getting higher and higher. Therefore, the connectors attached at pipes to deliver water are exposed to more severe environments than the pipes because crevice or galvanic corrosion is apt to occur at the fittings or the valves. Effects of the solid solution annealing, cooling rate after this heat treatment, and passivation on the corrosion properties of the shell mold casted SSC13 (STS304 alloy equivalent) were studied. The heating and quenching treatment more or less reduced hardness but effectively improved corrosion resistance. It was explained by the reduction of delta ferrite contents. Independent of heat treatment, the chemical passivation treatment also lowered corrosion rate but the improvement of corrosion resistance depended on temperature and time for passivation treatment indicating that the optimum conditions for passivation treatment were the bath temperature of 34 .deg. C and operating time of 10 minutes. Therefore it is suggested that the corrosion resistance of SSC13 can be effectively improved with the heat treatment, where SSC13 is heated for 10 minutes at 1120 °C and quenched and passivation treatment, where SSC13 is passivated for at least 10 seconds at 34 °C nitric acid solution.

  2. Bibliography on augmentation of convective heat and mass transfer

    International Nuclear Information System (INIS)

    Bergles, A.E.; Webb, R.L.; Junkhan, G.H.; Jensen, M.K.

    1979-05-01

    Heat transfer augmentation has developed into a major specialty area in heat transfer research and development. A bibliography of world literature on augmentation is presented. The literature is classified into passive augmentation techniques, which require no external power, and active techniques, which do require external power. The fourteen techniques are grouped in terms of their application to the various modes of heat transfer. Mass transfer is included for completeness. Key words are included with each citation for technique/mode identification. The total number of publications cited is 1,967, including 75 surveys of various techniques and 42 papers on performance evaluation of passive techniques. Patents are not included as they will be the subject of a future topical report

  3. Two types of a passive safety containment for a near future BWR with active and passive safety systems

    International Nuclear Information System (INIS)

    Sato, Takashi; Akinaga, Makoto; Kojima, Yoshihiro

    2009-01-01

    The paper presents two types of a passive safety containment for a near future BWR. They are named Mark S and Mark X containment. One of their common merits is very low peak pressure at severe accidents without venting the containment atmosphere to the environment. The PCV pressure can be moderated within the design pressure. Another merit is the capability to submerge the PCV and the RPV above the core level. The third merit is robustness against external events such as a large commercial airplane crash. Both the containments have a passive cooling core catcher that has radial cooling channels. The Mark S containment is made of reinforced concrete and applicable to a large power BWR up to 1830 MWe. The Mark X containment has the steel secondary containment and can be cooled by natural circulation of outside air. It can accommodate a medium power BWR up to 1380 MWe. In both cases the plants have active and passive safety systems constituting in-depth hybrid safety (IDHS). The IDHS provides not only hardware diversity between active and passive safety systems but also more importantly diversity of the ultimate heat sinks between the atmosphere and the sea water. Although the plant concept discussed in the paper uses well-established technology, plant performance including economy is innovatively and evolutionally improved. Nothing is new in the hardware but everything is new in the performance.

  4. Two types of a passive safety containment for a near future BWR with active and passive safety systems

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Takashi [Toshiba Corporation, IEC, Gen-SS, 8, Shinsugita-ho, Isogo-ku, Yokohama (Japan)], E-mail: takashi44.sato@glb.toshiba.co.jp; Akinaga, Makoto; Kojima, Yoshihiro [Toshiba Corporation, IEC, Gen-SS, 8, Shinsugita-ho, Isogo-ku, Yokohama (Japan)

    2009-09-15

    The paper presents two types of a passive safety containment for a near future BWR. They are named Mark S and Mark X containment. One of their common merits is very low peak pressure at severe accidents without venting the containment atmosphere to the environment. The PCV pressure can be moderated within the design pressure. Another merit is the capability to submerge the PCV and the RPV above the core level. The third merit is robustness against external events such as a large commercial airplane crash. Both the containments have a passive cooling core catcher that has radial cooling channels. The Mark S containment is made of reinforced concrete and applicable to a large power BWR up to 1830 MWe. The Mark X containment has the steel secondary containment and can be cooled by natural circulation of outside air. It can accommodate a medium power BWR up to 1380 MWe. In both cases the plants have active and passive safety systems constituting in-depth hybrid safety (IDHS). The IDHS provides not only hardware diversity between active and passive safety systems but also more importantly diversity of the ultimate heat sinks between the atmosphere and the sea water. Although the plant concept discussed in the paper uses well-established technology, plant performance including economy is innovatively and evolutionally improved. Nothing is new in the hardware but everything is new in the performance.

  5. A double-panel active segmented partition module using decoupled analog feedback controllers: numerical model.

    Science.gov (United States)

    Sagers, Jason D; Leishman, Timothy W; Blotter, Jonathan D

    2009-06-01

    Low-frequency sound transmission has long plagued the sound isolation performance of lightweight partitions. Over the past 2 decades, researchers have investigated actively controlled structures to prevent sound transmission from a source space into a receiving space. An approach using active segmented partitions (ASPs) seeks to improve low-frequency sound isolation capabilities. An ASP is a partition which has been mechanically and acoustically segmented into a number of small individually controlled modules. This paper provides a theoretical and numerical development of a single ASP module configuration, wherein each panel of the double-panel structure is independently actuated and controlled by an analog feedback controller. A numerical model is developed to estimate frequency response functions for the purpose of controller design, to understand the effects of acoustic coupling between the panels, to predict the transmission loss of the module in both passive and active states, and to demonstrate that the proposed ASP module will produce bidirectional sound isolation.

  6. Role of Passive Safety Features in Prevention And Mitigation of Severe Plant Conditions in Indian Advanced Heavy Water Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Vikas; Nayak, A.; Dhiman, M.; Kulkarni, P. P.; Vijayan, P. K.; Vaze, K. K. [Bhabha Atomic Research Centre, Mumbai (India)

    2013-10-15

    Pressing demands of economic competitiveness, the need for large-scale deployment, minimizing the need of human intervention, and experience from the past events and incidents at operating reactors have guided the evolution and innovations in reactor technologies. Indian innovative reactor 'AHWR' is a pressure-tube type natural circulation based boiling water reactor that is designed to meet such requirements, which essentially reflect the needs of next generation reactors. The reactor employs various passive features to prevent and mitigate accidental conditions, like a slightly negative void reactivity coefficient, passive poison injection to scram the reactor in event of failure of the wired shutdown systems, a large elevated pool of water as a heat sink inside the containment, passive decay heat removal based on natural circulation and passive valves, passive ECC injection, etc. It is designed to meet the fundamental safety requirements of safe shutdown, safe decay heat removal and confinement of activity with no impact in public domain, and hence, no need for emergency planning under all conceivable scenarios. This paper examines the role of the various passive safety systems in prevention and mitigation of severe plant conditions that may arise in event of multiple failures. For the purpose of demonstration of the effectiveness of its passive features, postulated scenarios on the lines of three major severe accidents in the history of nuclear power reactors are considered, namely; the Three Mile Island (TMI), Chernobyl and Fukushima accidents. Severe plant conditions along the lines of these scenarios are postulated to the extent conceivable in the reactor under consideration and analyzed using best estimate system thermal-hydraulics code RELAP5/Mod3.2. It is found that the various passive systems incorporated enable the reactor to tolerate the postulated accident conditions without causing severe plant conditions and core degradation.

  7. ROLE OF PASSIVE SAFETY FEATURES IN PREVENTION AND MITIGATION OF SEVERE PLANT CONDITIONS IN INDIAN ADVANCED HEAVY WATER REACTOR

    Directory of Open Access Journals (Sweden)

    VIKAS JAIN

    2013-10-01

    Full Text Available Pressing demands of economic competitiveness, the need for large-scale deployment, minimizing the need of human intervention, and experience from the past events and incidents at operating reactors have guided the evolution and innovations in reactor technologies. Indian innovative reactor ‘AHWR’ is a pressure-tube type natural circulation based boiling water reactor that is designed to meet such requirements, which essentially reflect the needs of next generation reactors. The reactor employs various passive features to prevent and mitigate accidental conditions, like a slightly negative void reactivity coefficient, passive poison injection to scram the reactor in event of failure of the wired shutdown systems, a large elevated pool of water as a heat sink inside the containment, passive decay heat removal based on natural circulation and passive valves, passive ECC injection, etc. It is designed to meet the fundamental safety requirements of safe shutdown, safe decay heat removal and confinement of activity with no impact in public domain, and hence, no need for emergency planning under all conceivable scenarios. This paper examines the role of the various passive safety systems in prevention and mitigation of severe plant conditions that may arise in event of multiple failures. For the purpose of demonstration of the effectiveness of its passive features, postulated scenarios on the lines of three major severe accidents in the history of nuclear power reactors are considered, namely; the Three Mile Island (TMI, Chernobyl and Fukushima accidents. Severe plant conditions along the lines of these scenarios are postulated to the extent conceivable in the reactor under consideration and analyzed using best estimate system thermal-hydraulics code RELAP5/Mod3.2. It is found that the various passive systems incorporated enable the reactor to tolerate the postulated accident conditions without causing severe plant conditions and core degradation.

  8. Analysis for Passive Safety Injection of IPSS in Various LOCAs

    International Nuclear Information System (INIS)

    Kim, Sangho; Chang, Soonheung

    2013-01-01

    The Fukushima accident shows US the possibility of accidents that are beyond a designed imagination. Lots of lessons can be shortly summarized into three issues. First of all, the original cause was the occurrence of a Station Black-Out (SBO). Even if engineers considered the possibility of a loss of offsite power enough to be managed, the failure of EDGs seemed to be unnoticed. The second is poor operation and accident management. They could not understand the overall system and did not check the availability of alternating systems. The third is the large release of radioactive materials outside the containment. Even if SBO occurred and the accident was not managed well, all the means must have prevented the large release out of containment. After that, lots of problems were pointed and numerous actions were carried out in each country. The representative proposals are AAC, additional physical barrier, bunker concept and large big tank. Integrated passive safety system (IPSS) was proposed as one of the solutions for enhancing the safety. IPSS can cope with a SBO and accidents with a SBO. IPSS has five functions which are passive decay heat removal, passive safety injection, passive containment cooling, passive in-vessel retention and filtered venting system. The results showed a high performance of removing decay heat through steam generator cooling by forming natural circulation in the primary circuit. The design concept of passive safety injection system (PSIS) consists of the injection line from integrated passive safety tank (IPST) to reactor vessel. The previous works were only focused on a double ended guillotine break LOCA in SBO. The purpose of this paper is to analyze the performance of PSIS in IPSS for various LOCAs by using MARS (Multi-dimensional Analysis of Reactor Safety) code. The simulated accidents were LOCAs which were accompanied with a SBO. The conditions of the LOCAs were varied only for the size of break. It shall show the capability of PSIS

  9. Precipitation and Latent Heating Distributions from Satellite Passive Microwave Radiometry. Part II: Evaluation of Estimates Using Independent Data

    Science.gov (United States)

    Yang, Song; Olson, William S.; Wang, Jian-Jian; Bell, Thomas L.; Smith, Eric A.; Kummerow, Christian D.

    2006-01-01

    Rainfall rate estimates from spaceborne microwave radiometers are generally accepted as reliable by a majority of the atmospheric science community. One of the Tropical Rainfall Measuring Mission (TRMM) facility rain-rate algorithms is based upon passive microwave observations from the TRMM Microwave Imager (TMI). In Part I of this series, improvements of the TMI algorithm that are required to introduce latent heating as an additional algorithm product are described. Here, estimates of surface rain rate, convective proportion, and latent heating are evaluated using independent ground-based estimates and satellite products. Instantaneous, 0.5 deg. -resolution estimates of surface rain rate over ocean from the improved TMI algorithm are well correlated with independent radar estimates (r approx. 0.88 over the Tropics), but bias reduction is the most significant improvement over earlier algorithms. The bias reduction is attributed to the greater breadth of cloud-resolving model simulations that support the improved algorithm and the more consistent and specific convective/stratiform rain separation method utilized. The bias of monthly 2.5 -resolution estimates is similarly reduced, with comparable correlations to radar estimates. Although the amount of independent latent heating data is limited, TMI-estimated latent heating profiles compare favorably with instantaneous estimates based upon dual-Doppler radar observations, and time series of surface rain-rate and heating profiles are generally consistent with those derived from rawinsonde analyses. Still, some biases in profile shape are evident, and these may be resolved with (a) additional contextual information brought to the estimation problem and/or (b) physically consistent and representative databases supporting the algorithm. A model of the random error in instantaneous 0.5 deg. -resolution rain-rate estimates appears to be consistent with the levels of error determined from TMI comparisons with collocated

  10. Precipitation and Latent Heating Distributions from Satellite Passive Microwave Radiometry. Part 2; Evaluation of Estimates Using Independent Data

    Science.gov (United States)

    Yang, Song; Olson, William S.; Wang, Jian-Jian; Bell, Thomas L.; Smith, Eric A.; Kummerow, Christian D.

    2004-01-01

    Rainfall rate estimates from space-borne k&ents are generally accepted as reliable by a majority of the atmospheric science commu&y. One-of the Tropical Rainfall Measuring Mission (TRh4M) facility rain rate algorithms is based upon passive microwave observations fiom the TRMM Microwave Imager (TMI). Part I of this study describes improvements in the TMI algorithm that are required to introduce cloud latent heating and drying as additional algorithm products. Here, estimates of surface rain rate, convective proportion, and latent heating are evaluated using independent ground-based estimates and satellite products. Instantaneous, OP5resolution estimates of surface rain rate over ocean fiom the improved TMI algorithm are well correlated with independent radar estimates (r approx. 0.88 over the Tropics), but bias reduction is the most significant improvement over forerunning algorithms. The bias reduction is attributed to the greater breadth of cloud-resolving model simulations that support the improved algorithm, and the more consistent and specific convective/stratiform rain separation method utilized. The bias of monthly, 2.5 deg. -resolution estimates is similarly reduced, with comparable correlations to radar estimates. Although the amount of independent latent heating data are limited, TMI estimated latent heating profiles compare favorably with instantaneous estimates based upon dual-Doppler radar observations, and time series of surface rain rate and heating profiles are generally consistent with those derived from rawinsonde analyses. Still, some biases in profile shape are evident, and these may be resolved with: (a) additional contextual information brought to the estimation problem, and/or; (b) physically-consistent and representative databases supporting the algorithm. A model of the random error in instantaneous, 0.5 deg-resolution rain rate estimates appears to be consistent with the levels of error determined from TMI comparisons to collocated radar

  11. Performance of a passive emergency heat removal system of advanced reactors in two-phase flow and with high concentration of non-condensable

    International Nuclear Information System (INIS)

    Macedo, Luiz Alberto

    2008-01-01

    The research and the development of passive emergency cooling systems are necessary for the new generation of thermo-nuclear systems. Some basic information on the operation of these systems require the research of some relative processes to the natural circulation, mainly in conditions of two-phase flow involving processes of condensation in the presence of non-condensable gases, because many found situations are new. The experimental facility called Bancada de Circulacao Natural (BCN) was used for the realization of tests with diverse concentrations of non-condensable and power levels. The non-condensable gas present in the circuit decreases the rate of heat transfer for the secondary of the heat exchanger, determining low efficiency of the heat exchanger. High concentration of non-condensable in the vapor condensation, determines negative pressure, and cause the inversion of the flow in the circuit. The initial concentration of non-condensable and the geometry of the circuit, in the inlet of the heat exchanger, determines the establishment of transitory with two-phase flow. The BCN was performed with the computational code of Analysis of Accidents and Thermal-Hydraulics RELAP5/MOD 3.3 and, the calculated values had been compared with the experimental data, presenting good agreement for small non-condensable concentrations. The values calculated for high concentrations of non-condensable had been satisfactory after the circuit to have reached the temperature of saturation in the electric heater. (author)

  12. Novel Power Electronics Three-Dimensional Heat Exchanger: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Bennion, K.; Cousineau, J.; Lustbader, J.; Narumanchi, S.

    2014-08-01

    Electric drive systems for vehicle propulsion enable technologies critical to meeting challenges for energy, environmental, and economic security. Enabling cost-effective electric drive systems requires reductions in inverter power semiconductor area. As critical components of the electric drive system are made smaller, heat removal becomes an increasing challenge. In this paper, we demonstrate an integrated approach to the design of thermal management systems for power semiconductors that matches the passive thermal resistance of the packaging with the active convective cooling performance of the heat exchanger. The heat exchanger concept builds on existing semiconductor thermal management improvements described in literature and patents, which include improved bonded interface materials, direct cooling of the semiconductor packages, and double-sided cooling. The key difference in the described concept is the achievement of high heat transfer performance with less aggressive cooling techniques by optimizing the passive and active heat transfer paths. An extruded aluminum design was selected because of its lower tooling cost, higher performance, and scalability in comparison to cast aluminum. Results demonstrated a heat flux improvement of a factor of two, and a package heat density improvement over 30%, which achieved the thermal performance targets.

  13. Passive heat transfer in a turbulent channel flow simulation using large eddy simulation based on the lattice Boltzmann method framework

    Energy Technology Data Exchange (ETDEWEB)

    Wu Hong [National Key Laboratory of Science and Technology on Aero-Engine Aero-Thermodynamics, Beihang University, Beijing 100191 (China); Wang Jiao, E-mail: wangjiao@sjp.buaa.edu.cn [National Key Laboratory of Science and Technology on Aero-Engine Aero-Thermodynamics, Beihang University, Beijing 100191 (China); Tao Zhi [National Key Laboratory of Science and Technology on Aero-Engine Aero-Thermodynamics, Beihang University, Beijing 100191 (China)

    2011-12-15

    Highlights: Black-Right-Pointing-Pointer A double MRT-LBM is used to study heat transfer in turbulent channel flow. Black-Right-Pointing-Pointer Turbulent Pr is modeled by dynamic subgrid scale model. Black-Right-Pointing-Pointer Temperature gradients are calculated by the non-equilibrium temperature distribution moments. - Abstract: In this paper, a large eddy simulation based on the lattice Boltzmann framework is carried out to simulate the heat transfer in a turbulent channel flow, in which the temperature can be regarded as a passive scalar. A double multiple relaxation time (DMRT) thermal lattice Boltzmann model is employed. While applying DMRT, a multiple relaxation time D3Q19 model is used to simulate the flow field, and a multiple relaxation time D3Q7 model is used to simulate the temperature field. The dynamic subgrid stress model, in which the turbulent eddy viscosity and the turbulent Prandtl number are dynamically computed, is integrated to describe the subgrid effect. Not only the strain rate but also the temperature gradient is calculated locally by the non-equilibrium moments. The Reynolds number based on the shear velocity and channel half height is 180. The molecular Prandtl numbers are set to be 0.025 and 0.71. Statistical quantities, such as the average velocity, average temperature, Reynolds stress, root mean square (RMS) velocity fluctuations, RMS temperature and turbulent heat flux are obtained and compared with the available data. The results demonstrate great reliability of DMRT-LES in studying turbulence.

  14. Modeling the thermal absorption factor of photovoltaic/thermal combi-panels

    International Nuclear Information System (INIS)

    Santbergen, R.; Zolingen, R.J.Ch. van

    2006-01-01

    In a photovoltaic/thermal combi-panel solar cells generate electricity while residual heat is extracted to be used for tap water heating or room heating. In such a panel the entire solar spectrum can be used in principle. Unfortunately long wavelength solar irradiance is poorly absorbed by the semiconductor material in standard solar cells. A computer model was developed to determine the thermal absorption factor of crystalline silicon solar cells. It was found that for a standard untextured solar cell with a silver back contact a relatively large amount of long wavelength irradiance is lost by reflection resulting in an absorption factor of only 74%. The model was then used to investigate ways to increase this absorption factor. One way is absorbing long wavelength irradiance in a second absorber behind a semi-transparent solar cell. According to the model this will increase the total absorption factor to 87%. The second way is to absorb irradiance in the back contact of the solar cell by using rough interfaces in combination with a non-standard metal as back contact. Theoretically the absorption factor can then be increased to 85%

  15. Elucidating the effects of solar panel waste glass substitution on the physical and mechanical characteristics of clay bricks.

    Science.gov (United States)

    Lin, Kae-Long; Huang, Long-Sheng; Shie, Je-Lueng; Cheng, Ching-Jung; Lee, Ching-Hwa; Chang, Tien-Chin

    2013-01-01

    This study deals with the effect of solar panel waste glass on fired clay bricks. Brick samples were heated to temperatures which varied from 700-1000 degrees C for 6 h, with a heating rate of 10 degrees C min(-1). The material properties of the resultant material were then determined, including speciation variation, loss on ignition, shrinkage, bulk density, 24-h absorption rate, compressive strength and salt crystallization. The results indicate that increasing the amount of solar panel waste glass resulted in a decrease in the water absorption rate and an increase in the compressive strength of the solar panel waste glass bricks. The 24-h absorption rate and compressive strength of the solar panel waste glass brick made from samples containing 30% solar panel waste glass sintered at 1000 degrees C all met the Chinese National Standard (CNS) building requirements for first-class brick (compressive strengths and water absorption of the bricks were 300 kg cm(-2) and 10% of the brick, respectively). The addition of solar panel waste glass to the mixture reduced the degree of firing shrinkage. The salt crystallization test and wet-dry tests showed that the addition of solar panel waste glass had highly beneficial effects in that it increased the durability of the bricks. This indicates that solar panel waste glass is indeed suitable for the partial replacement of clay in bricks.

  16. The passive house, a showbag; Wundertuete Passivhaus

    Energy Technology Data Exchange (ETDEWEB)

    Mardo, Dietrich; Unselt, Roland

    2011-03-07

    The contribution was written in close cooperation with Roland Unselt, graduate building operation engineer. In No. 4/2010, Ronald Unselt stated his critical and clear views on heat pumps. Here, he looks back on 20 years of construction of low-energy and passive buildings. He outlines the technical limits and identifies weak points and deficiencies. He shows problematic aspects and also practicable solutions that have been tried successfully.

  17. Fast brazing development for the joining of the beryllium armor layer for the ITER First Wall panels

    International Nuclear Information System (INIS)

    Buodot, C.; Boireau, B.; Lorenzetto, P.; Macel, D.

    2006-01-01

    In order to reduce cost and manufacturing time induction brazing is being developed as an alternative to Hot Isostatic Pressing for the joining of the beryllium armor onto the copper alloy heat sink material for the manufacture of First Wall panels for the ITER Blanket. The copper alloy that is currently adopted by ITER is a Copper Chromium Zirconium alloy. Its good mechanical properties are obtained by precipitation hardening by means of an ageing heat treatment at a temperature of about 480 o C. In order to avoid over-ageing and keep acceptable mechanical properties, brazing at higher temperatures must therefore be done as fast as possible. The flat geometry of a panel is not familiar for induction process; nevertheless, a development work was done validating the feasibility of joining beryllium tiles onto a copper chromium zirconium flat surface of a panel by induction brazing process. The development was done in 2 stages: validation of the capability of the induction process to realise a heat cycle on a dummy panel and in parallel, validation of the brazing parameters giving acceptable mechanical results on the beryllium CuCrZr joint. A flat pancake inductor was manufactured and tested on a dummy panel in an induction brazing vessel manufactured for this purpose. Several heating cycles were done with the aim of defining a cycle that gives uniform temperature at the interface of all the beryllium tiles on the entire panel surface. These cycles gave us a temperature range in which the brazing can be performed. A special device for brazing small mock up was also manufactured. This was for the metallurgical characterisation program. Many brazing samples where done and mechanically characterised. Unfortunately, this first metallurgical stage led to unacceptably low shear test values. A complete analysis of this non conformance put in evidence that the bad results were due to the braze material that was not adapted to this process. By changing the braze material

  18. Continued evaluation of compact heat exchangers for OTEC evaluation. Final report

    Energy Technology Data Exchange (ETDEWEB)

    McGowan, J.G.

    1979-10-01

    The objectives of this work investigating the applicability of compact plate heat type heat exchangers to OTEC power systems were: (1) an analytical and experimental evaluation of the performance characteristics of compact heat exchangers using ammonia as the working fluid operating under the entire range of OTEC system conditions; and (2) an evaluation of the applicable manufacturing processes, maintenance requirements, and arrangement concepts for large-scale compact OTEC heat exchangers with specific emphasis on total economics. The work was carried out to establish the applicability of compact plate type heat exchangers to OTEC power systems and to provide: (1) experimental verification of predicted performance (heat transfer and fluid flow) under OTEC operating conditions (using NH/sub 3/); (2) provide initial performance data for several desirable plate type OTEC heat exchanger panels; (3) provide test apparatus for continued experimental testing of OTEC compact heat exchanger panels; and (4) provide design information on applicable manufacturing processes maintenance requirements and arrangement concepts for plate type heat exchangers.

  19. An experimental study of high pressure steam condensation in a vertical tube of passive secondary condensation system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Jae; No, Hee Cheon [KAIST, Taejon (Korea, Republic of)

    1998-07-01

    To investigate the physical parameters of PSCS (Passive Secondary Condensation System) which is a passive residual heat removal system of CP-1300, the high pressure condensation experiments are performed in a small scale experimental facility. The experimental parameters are the local heat flux and the transfer coefficient and the pressure drop in a condensation heat trasnfer. The film condensation heat transfer coefficients in a vertical tube are calculated from the measured wall temperature difference and compared with the analytical models. A new analytical condensation model is developed based on the annular film flow model. The present model gives marginally better results than those from the Shah model in comparison with the experimental data in the database. Also, experimental data are compared with the results of the RELAP5/MOD3.2 thermal hydraulic code. The RELAP5/MOD3.2 underpredicts the condensation heat transfer coefficients of the present experiment by 50 %.

  20. Slow-wave metamaterial open panels for efficient reduction of low-frequency sound transmission

    Science.gov (United States)

    Yang, Jieun; Lee, Joong Seok; Lee, Hyeong Rae; Kang, Yeon June; Kim, Yoon Young

    2018-02-01

    Sound transmission reduction is typically governed by the mass law, requiring thicker panels to handle lower frequencies. When open holes must be inserted in panels for heat transfer, ventilation, or other purposes, the efficient reduction of sound transmission through holey panels becomes difficult, especially in the low-frequency ranges. Here, we propose slow-wave metamaterial open panels that can dramatically lower the working frequencies of sound transmission loss. Global resonances originating from slow waves realized by multiply inserted, elaborately designed subwavelength rigid partitions between two thin holey plates contribute to sound transmission reductions at lower frequencies. Owing to the dispersive characteristics of the present metamaterial panels, local resonances that trap sound in the partitions also occur at higher frequencies, exhibiting negative effective bulk moduli and zero effective velocities. As a result, low-frequency broadened sound transmission reduction is realized efficiently in the present metamaterial panels. The theoretical model of the proposed metamaterial open panels is derived using an effective medium approach and verified by numerical and experimental investigations.

  1. Space Shuttle Orbiter Wing-Leading-Edge Panel Thermo-Mechanical Analysis for Entry Conditions

    Science.gov (United States)

    Knight, Norman F., Jr.; Song, Kyongchan; Raju, Ivatury S.

    2010-01-01

    Linear elastic, thermo-mechanical stress analyses of the Space Shuttle Orbiter wing-leading-edge panels is presented for entry heating conditions. The wing-leading-edge panels are made from reinforced carbon-carbon and serve as a part of the overall thermal protection system. Three-dimensional finite element models are described for three configurations: integrated configuration, an independent single-panel configuration, and a local lower-apex joggle segment. Entry temperature conditions are imposed and the through-the-thickness response is examined. From the integrated model, it was concluded that individual panels can be analyzed independently since minimal interaction between adjacent components occurred. From the independent single-panel model, it was concluded that increased through-the-thickness stress levels developed all along the chord of a panel s slip-side joggle region, and hence isolated local joggle sections will exhibit the same trend. From the local joggle models, it was concluded that two-dimensional plane-strain models can be used to study the influence of subsurface defects along the slip-side joggle region of these panels.

  2. Fundamental studies of passivity and passivity breakdown

    International Nuclear Information System (INIS)

    Macdonald, D.D.; Urquidi-Macdonald, M.; Song, H.; Biaggio-Rocha, S.; Searson, P.

    1991-11-01

    This report summarizes the findings of our fundamental research program on passivity and passivity breakdown. During the past three and one half years in this program (including the three year incrementally-funded grant prior to the present grant), we developed and experimentally tested various physical models for the growth and breakdown of passive films on metal surfaces. These models belong to a general class termed ''point defects models'' (PDMs), in which the growth and breakdown of passive films are described in terms of the movement of anion and cation vacancies

  3. Indonesian dengue burden estimates: review of evidence by an expert panel.

    Science.gov (United States)

    Wahyono, T Y M; Nealon, J; Beucher, S; Prayitno, A; Moureau, A; Nawawi, S; Thabrany, H; Nadjib, M

    2017-08-01

    Routine, passive surveillance systems tend to underestimate the burden of communicable diseases such as dengue. When empirical methods are unavailable, complimentary opinion-based or extrapolative methods have been employed. Here, an expert Delphi panel estimated the proportion of dengue captured by the Indonesian surveillance system, and associated health system parameters. Following presentation of medical and epidemiological data and subsequent discussions, the panel made iterative estimates from which expansion factors (EF), the ratio of total:reported cases, were calculated. Panelists estimated that of all symptomatic Indonesian dengue episodes, 57·8% (95% confidence interval (CI) 46·6-59·8) enter healthcare facilities to seek treatment; 39·3% (95% CI 32·8-42·0) are diagnosed as dengue; and 20·3% (95% CI 16·1-24·3) are subsequently reported in the surveillance system. They estimated most hospitalizations occur in the public sector, while ~55% of ambulatory episodes are seen privately. These estimates gave an overall EF of 5·00; hospitalized EF of 1·66; and ambulatory EF of 34·01 which, when combined with passive surveillance data, equates to an annual average (2006-2015) of 612 005 dengue cases, and 183 297 hospitalizations. These estimates are lower than those published elsewhere, perhaps due to case definitions, local clinical perceptions and treatment-seeking behavior. These findings complement global burden estimates, support health economic analyses, and can be used to inform decision-making.

  4. Heating and cooling with ground-loop heat pumps; Heizen und Kuehlen mit erdgekoppelten Waermepumpen

    Energy Technology Data Exchange (ETDEWEB)

    Afjei, Th.; Dott, R. [Institut Energie am Bau, Fachhochschule Nordwestschweiz (FHNW), Muttenz (Switzerland); Huber, A. [Huber Energietechnik AG, Zuerich (Switzerland)

    2007-08-15

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of the SFOE-project 'Heating and cooling with ground coupled heat pumps' in which the benefits and costs of a heat pump heating and cooling system with a borehole heat exchanger were examined. In particular the dimensioning of the hydraulic system, control concept and user behaviour are dealt with. The results of the simulations of thermal building behaviour with MATLAB/SIMULINK, CARNOT, and EWS are discussed. The results of parameter studies carried out, including varying shading, cooling characteristic curves, temperature differences in the heat exchanger and the dead time between heating and cooling mode are discussed. These showed that a simple system with heat pump and borehole heat exchanger for heating or preparation of domestic hot water as well as for passive cooling proved to be the best choice.

  5. Aerothermoelastic analysis of panel flutter based on the absolute nodal coordinate formulation

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, Laith K., E-mail: laithabbass@yahoo.com; Rui, Xiaoting, E-mail: ruixt@163.com [Nanjing University of Science and Technology, Institute of Launch Dynamics (China); Marzocca, Piergiovanni, E-mail: pmarzocc@clarkson.edu [Clarkson University, Mechanical and Aeronautical Engineering Department (United States)

    2015-02-15

    Panels of reentry vehicles are subjected to a wide range of flow conditions during ascent and reentry phases. The flow can vary from subsonic continuum flow to hypersonic rarefied flow with wide ranging dynamic pressure and associated aerodynamic heating. One of the main design considerations is the assurance of safety against panel flutter under the flow conditions characterized by sever thermal environment. This paper deals with supersonic/hypersonic flutter analysis of panels exposed to a temperature field. A 3-D rectangular plate element of variable thickness based on absolute nodal coordinate formulation (ANCF) has been developed for the structural model and subjected to an assumed thermal profile that can result from any residual heat seeping into the metallic panels through the thermal protection systems. A continuum mechanics approach for the definition of the elastic forces within the finite element is considered. Both shear strain and transverse normal strain are taken into account. The aerodynamic force is evaluated by considering the first-order piston theory to linearize the potential flow and is coupled with the structural model to account for pressure loading. A provision is made to take into account the effect of arbitrary flow directions with respect to the panel edges. Aerothermoelastic equations using ANCF are derived and solved numerically. Values of critical dynamic pressure are obtained by a modal approach, in which the mode shapes are obtained by ANCF. A detailed parametric study is carried out to observe the effects of different temperature loadings, flow angle directions, and aspect ratios on the flutter boundary.

  6. Aerothermoelastic analysis of panel flutter based on the absolute nodal coordinate formulation

    International Nuclear Information System (INIS)

    Abbas, Laith K.; Rui, Xiaoting; Marzocca, Piergiovanni

    2015-01-01

    Panels of reentry vehicles are subjected to a wide range of flow conditions during ascent and reentry phases. The flow can vary from subsonic continuum flow to hypersonic rarefied flow with wide ranging dynamic pressure and associated aerodynamic heating. One of the main design considerations is the assurance of safety against panel flutter under the flow conditions characterized by sever thermal environment. This paper deals with supersonic/hypersonic flutter analysis of panels exposed to a temperature field. A 3-D rectangular plate element of variable thickness based on absolute nodal coordinate formulation (ANCF) has been developed for the structural model and subjected to an assumed thermal profile that can result from any residual heat seeping into the metallic panels through the thermal protection systems. A continuum mechanics approach for the definition of the elastic forces within the finite element is considered. Both shear strain and transverse normal strain are taken into account. The aerodynamic force is evaluated by considering the first-order piston theory to linearize the potential flow and is coupled with the structural model to account for pressure loading. A provision is made to take into account the effect of arbitrary flow directions with respect to the panel edges. Aerothermoelastic equations using ANCF are derived and solved numerically. Values of critical dynamic pressure are obtained by a modal approach, in which the mode shapes are obtained by ANCF. A detailed parametric study is carried out to observe the effects of different temperature loadings, flow angle directions, and aspect ratios on the flutter boundary

  7. Broadband transmission noise reduction of smart panels featuring piezoelectric shunt circuits and sound-absorbing material.

    Science.gov (United States)

    Kim, Jaehwan; Lee, Joong-Kuen

    2002-09-01

    The possibility of a broadband noise reduction of piezoelectric smart panels is experimentally studied. A piezoelectric smart panel is basically a plate structure on which piezoelectric patches with electrical shunt circuits are mounted and sound-absorbing material is bonded on the surface of the structure. Sound-absorbing material can absorb the sound transmitted at the midfrequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to reduce the sound transmission at low panel resonance frequencies, piezoelectric damping using the measured electrical impedance model is adopted. A resonant shunt circuit for piezoelectric shunt damping is composed of resistor and inductor in series, and they are determined by maximizing the dissipated energy through the circuit. The transmitted noise-reduction performance of smart panels is tested in an acoustic tunnel. The tunnel is a square cross-sectional tube and a loudspeaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across panels is measured. When an absorbing material is bonded on a single plate, a remarkable transmitted noise reduction in the midfrequency region is observed except for the fundamental resonance frequency of the plate. By enabling the piezoelectric shunt damping, noise reduction is achieved at the resonance frequency as well. Piezoelectric smart panels incorporating passive absorbing material and piezoelectric shunt damping is a promising technology for noise reduction over a broadband of frequencies.

  8. Indoor air quality in passive and conventional new houses in Sweden

    DEFF Research Database (Denmark)

    Langer, Sarka; Bekö, Gabriel; Bloom, Erica

    2015-01-01

    The indoor environment was evaluated in 20 new passive houses and 21 new conventionally built houses during the 2012/2013 and 2013/2014 heating seasons. Temperature, relative humidity (RH), the concentrations of NO2, ozone, formaldehyde, volatile organic compounds (VOC) and viable microbiological...... flora were measured. Air exchange rates (AER) were estimated from the CO2 concentrations measured in the bedrooms. The median AER was slightly higher in the passive houses than in the conventional ones (0.68h-1 vs. 0.60h-1). The median concentrations in the passive and the conventional buildings were 10...... and 12μg/m3 for NO2, 9.7 and 11μg/m3 for ozone, 11 and 16μg/m3 for formaldehyde, and 270 and 150μg/m3 for TVOC, respectively. Significant differences in the TVOC and formaldehyde concentrations between the two groups of buildings indicated substantial sources of TVOC present in the passive houses, while...

  9. Buck Converter with Soft-Switching Cells for PV Panel Applications

    Directory of Open Access Journals (Sweden)

    Cheng-Tao Tsai

    2016-03-01

    Full Text Available In power conversion of photovoltaic (PV energy, a hard-switching buck converter always generates some disadvantages. For example, serious electromagnetic interference (EMI, high switching losses, and stresses on an active switch (metal-oxide-semiconductor-field-effect-transistor, MOSFET, and high reverse-recovery losses of a freewheeling diode result in low conversion efficiency. To release these disadvantages, a buck converter with soft-switching cells for PV panel applications is proposed. To create zero-voltage-switching (ZVS features of the active switches, a simple active soft-switching cell with an inductor, a capacitor, and a MOSFET is incorporated into the proposed buck converter. Therefore, the switching losses and stresses of the active switches and EMI can be reduced significantly. To reduce reverse-recovery losses of a freewheeling diode, a simple passive soft-switching cell with a capacitor and two diodes is implemented. To verify the performance and the feasibility of the proposed buck converter with soft-switching cells for PV panel applications, a prototype soft-switching buck converter is built and implemented by using a maximum-power-point-tracking (MPPT method. Simulated and experimental results are presented from a 100 W soft-switching buck converter for PV panel applications.

  10. User manual for SPLASH (Single Panel Lamp and Shroud Helper).

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Marvin Elwood

    2006-02-01

    The radiant heat test facility develops test sets providing well-characterized thermal environments, often representing fires. Many of the components and procedures have become standardized to such an extent that the development of a specialized design tool to determine optimal configurations for radiant heat experiments was appropriate. SPLASH (Single Panel Lamp and Shroud Helper) is that tool. SPLASH is implemented as a user-friendly, Windows-based program that allows a designer to describe a test setup in terms of parameters such as number of lamps, power, position, and separation distance. This document is a user manual for that software. Any incidental descriptions of theory are only for the purpose of defining the model inputs. The theory for the underlying model is described in SAND2005-2947 (Ref. [1]). SPLASH provides a graphical user interface to define lamp panel and shroud designs parametrically, solves the resulting radiation enclosure problem for up to 2500 surfaces, and provides post-processing to facilitate understanding and documentation of analyzed designs.

  11. Causes and Architectural Solution to Heat and Nonconducive Air ...

    African Journals Online (AJOL)

    Passive Solar building aspire to maintain interior thermal comfort all through the sun's daily and annual cycles at the same time as reducing the requirement for active cooling and heating systems. Passive solar building design is one fraction of green building design and does not consist of active systems such as ...

  12. Passive solar design strategies: Remodeling guidelines for conserving energy at home

    Energy Technology Data Exchange (ETDEWEB)

    1991-01-01

    The idea of passive solar is simple, but applying it effectively does require information and attention to the details of design and construction. Some passive solar techniques are modest and low-cost, and require only small changes in remodeler's typical practice. At the other end of the spectrum, some passive solar systems can almost eliminate a house's need for purchased heating (and in some cases, cooling) energy -- but probably at a relatively high first cost. In between are a broad range of energy-conserving passive solar techniques. Whether or not they are cost-effective, practical and attractive enough to offer a market advantage to any individual remodeler depends on very specific factors such as local costs, climate, and market characteristics. Passive solar design strategies: Remodeling Guidelines For Conserving Energy At Homes is written to help give remodelers the information they need to make these decisions. Passive Solar Design Strategies is a package in three basic parts: The Guidelines contain information about passive solar techniques and how they work, and provides specific examples of systems which will save various percentages of energy; The Worksheets offer a simple, fill-in-the-blank method to pre-evaluate the performance of a specific design; The Worked Example demonstrates how to complete the worksheets for a typical residence.

  13. Solar-heated swimming school--Wilmington, Delaware

    Science.gov (United States)

    1981-01-01

    Report describes operation, installation, and performance of solar-energy system which provides alternative to natural gas pool heating. System is comprised of 2,500 square feet of liquid flat-plate collectors connected to 3,600 galloon; gallongalloon storage tank, with microcomputer-based controls. Extension of building incorporates vertical-wall, passive collection system which provides quarter of heated fresh air for office.

  14. Alternative Shear Panel Configurations for Light Wood Construction. Development, Seismic Performance, and Design Guidance

    Science.gov (United States)

    Wilcoski, James; Fischer, Chad; Allison, Tim; Malach, Kelly Jo

    2002-04-01

    Shear panels are used in light wood construction to resist lateral loads resulting from earthquakes or strong winds. These panels are typically made of wooden sheathing nailed to building frame members, but this standard panel design interferes with the installation of sheet insulation. A non-insulated shear panel conducts heat between the building interior and exterior wasting considerable amounts of energy. Several alternative shear panel designs were developed to avoid this insulation-mounting problem and sample panels were tested according to standard cyclic test protocols. One of the alternative designs consisted of diagonal steel straps nailed directly to the structural framing. Several others consisted of sheathing nailed to 2 x 4 framing then set into a larger 2 x 6 structural frame in such a way that no sheathing protruded beyond the edge of the 2 x 6 members. Also samples of industry-standard shear panels were constructed and tested in order to establish a performance baseline. Analytical models were developed to size test panels and predict panel behavior. A procedure was developed for establishing design capacities based on both test data and established baseline panel design capacity. The behavior of each panel configuration is documented and recommended design capacities are presented.

  15. Post-accident cooling capacity analysis of the AP1000 passive spent fuel pool cooling system

    International Nuclear Information System (INIS)

    Su Xia

    2013-01-01

    The passive design is used in AP1000 spent fuel pool cooling system. The decay heat of the spent fuel is removed by heating-boiling method, and makeup water is provided passively and continuously to ensure the safety of the spent fuel. Based on the analysis of the post-accident cooling capacity of the spent fuel cooling system, it is found that post-accident first 72-hour cooling under normal refueling condition and emergency full-core offload condition can be maintained by passive makeup from safety water source; 56 hours have to be waited under full core refueling condition to ensure the safety of the core and the spent fuel pool. Long-term cooling could be conducted through reserved safety interface. Makeup measure is available after accident and limited operation is needed. Makeup under control could maintain the spent fuel at sub-critical condition. Compared with traditional spent fuel pool cooling system design, the AP1000 design respond more effectively to LOCA accidents. (authors)

  16. Fire Behavior of Rigid Polyurethane Foam and Metal Faced Polyurethane Sandwich Panels and Its Fire Hazard Assessment

    Directory of Open Access Journals (Sweden)

    S. Bakhtiyari

    2009-12-01

    Full Text Available Reaction to fire of fire-retarded rigid PUR foams and two types of metal faced rigid polyurethane foam core sandwich panel was evaluated by using cone calorimeter test method. The tests were carried out in various radiative heat fluxes from 15 to 75 kW/m2. The radiation rate effect on reaction to fire parameters, including time to ignition (TTI, peak of heat release rate (PRHR, total heat release (THR, average heat release rate (Av.RHR and average heat of combustion (Av.EHC was investigated. The phenomenon of char forming, when the foam is exposed to heat, leads to the formation of a protective layer on the surface of foam and hence no direct relation exists between Av.RHR and average specific mass loss rate (Av.Spec.MLR of foam with increased radiation rate. In addition, the increased PRHR with foam density was also very smooth. The relation between TTI and heat flux was investigated for the foam and its corresponding correlation has been achieved with a specified density. Fire hazard assessment of foams and sandwitch panels was carried out by adopting Petrella and Richardson fire risk classification methods. The assessment results showed that rigid PUR foam and PUR sandwich panels may have a high contribution to bring the room to critical flashover condition, but the risk is intermediate from the viewpoint of fire endurance. The reasons of these risk levels are attributed to a very short TTI, relative high PRHR and an intermediate amount of THR. Decrease in foam density reduces heat release but it shows no significant effect on reducing flashover hazard.

  17. Technical feasibility and reliability of passive safety systems of AC600

    International Nuclear Information System (INIS)

    Niu, W.; Zeng, X.

    1996-01-01

    The first step conceptual design of the 600 MWe advanced PWR (AC-600) has been finished by the Nuclear Power Institute of China. Experiments on the passive system of AC-600 are being carried out, and are expected to be completed next year. The main research emphases of AC-600 conceptual design include the advanced core, the passive safety system and simplification. The design objective of AC-600 is that the safety, reliability, maintainability, operation cost and construction period are all improved upon compared to those of PWR plant. One of important means to achieve the objective is using a passive system, which has the following functions whenever its operation is required: providing the reactor core with enough coolant when others fail to make up the lost coolant; reactor residual heat removal; cooling and reducing pressure in the containment and preventing radioactive substances from being released into the environment after occurrence of accident (e.g. LOCA). The system should meet the single failure criterion, and keep operating when a single active component or passive component breaks down during the first 72 hour period after occurrence of accident, or in the long period following the 72 hour period. The passive safety system of AC-600 is composed of the primary safety injection system, the secondary emergency core residual heat removal system and the containment cooling system. The design of the system follows some relevant rules and criteria used by current PWR plant. The system has the ability to bear single failure, two complete separate subsystems are considered, each designed for 100% working capacity. Normal operation is separate from safety operation and avoids cross coupling and interference between systems, improves the reliability of components, and makes it easy to maintain, inspect and test the system. The paper discusses the technical feasibility and reliability of the passive safety system of AC-600, and some issues and test plans are also

  18. Technical feasibility and reliability of passive safety systems of AC600

    Energy Technology Data Exchange (ETDEWEB)

    Niu, W; Zeng, X [Nuclear Power Inst. of China, Chendu (China)

    1996-12-01

    The first step conceptual design of the 600 MWe advanced PWR (AC-600) has been finished. Experiments on the passive system of AC-600 are being carried out, and are expected to be completed next year. The main research emphases of AC-600 conceptual design include the advanced core, the passive safety system and simplification. The design objective of AC-600 is that the safety, reliability, maintainability, operation cost and construction period are all improved upon compared to those of PWR plant. One of important means to achieve the objective is using a passive system, which has the following functions whenever its operation is required: providing the reactor core with enough coolant when others fail to make up the lost coolant; reactor residual heat removal; cooling and reducing pressure in the containment and preventing radioactive substances from being released into the environment after occurrence of accident (e.g. LOCA). The system should meet the single failure criterion, and keep operating when a single active component or passive component breaks down during the first 72 hour period after occurrence of accident, or in the long period following the 72 hour period. The passive safety system of AC-600 is composed of the primary safety injection system, the secondary emergency core residual heat removal system and the containment cooling system. The design of the system follows some relevant rules and criteria used by current PWR plant. The system has the ability to bear single failure, two complete separate subsystems are considered, each designed for 100% working capacity. Normal operation is separate from safety operation and avoids cross coupling and interference between systems, improves the reliability of components, and makes it easy to maintain, inspect and test the system. The paper discusses the technical feasibility and reliability of the passive safety system of AC-600, and some issues and test plans are also involved. (author). 3 figs, 1 tab.

  19. Bibliography on augmentation of convective heat and mass transfer-II

    Energy Technology Data Exchange (ETDEWEB)

    Bergles, A.E.; Nirmalan, V.; Junkhan, G.H.; Webb, R.L.

    1983-12-01

    Heat transfer augmentation has developed into a major specialty area in heat transfer research and development. This report presents and updated bibliography of world literature on augmentation. The literature is classified into passive augmentation techniques, which require no external power, and active techniques, which do require external power. The fifteen techniques are grouped in terms of their applications to the various modes of heat transfer. Mass transfer is included for completeness. Key words are included with each citation for technique/mode identification. The total number of publications cited is 3045, including 135 surveys of various techniques and 86 papers on performance evaluation of passive techniques. Patents are not included, as they are the subject of a separate bibliographic report.

  20. Preservation of FFTF Data Related to Passive Safety Testing

    International Nuclear Information System (INIS)

    Wootan, David W.; Butner, R. Scott; Omberg, Ronald P.; Makenas, Bruce J.; Nielsen, Deborah L.

    2010-01-01

    One of the goals of the Fuel Cycle Research and Development Program (FCRD) is to preserve the knowledge that has been gained in the United States on Liquid Metal Reactors (LMR). A key area deserving special attention for preservation is the data relating to passive safety testing that was conducted in FFTF and EBR-II during the 1980's. Accidents at Unit 4 of the Chernobyl Station and Unit 2 at Three Mile Island changed the safety paradigm of the nuclear power industry. New emphasis was placed on assured safety based on intrinsic plant characteristics that protect not only the public, but the significant investment in the plant as well. Plants designated to perform in this manner are considered to be passively safe since no active sensor/alarm system or human intervention is required to bring the reactor to a safe shutdown condition. The liquid metal reactor (LMR) has several key characteristics needed for a passively safe reactor: reactor coolant with superior heat transfer capability and very high boiling point, low (atmospheric) system pressures, and reliable negative reactivity feedback. The credibility of the design for a passively safe LMR rests on two issues: the validity of analytic methods used to predict passive safety performance and the availability of relevant test data to calibrate design tools. Safety analysis methods used to analyze LMRs under the old safety paradigm were focused on calculating the source term for the Core Disruptive Accident. Passive safety design requires refined analysis methods for transient events because treatment of the detailed reactivity feedbacks is important in predicting the response of the reactor. Similarly, analytic tools should be calibrated against actual test experience in existing LMR facilities. The principal objectives of the combined FFTF natural circulation and Passive Safety Testing program were: (1) to verify natural circulation as a reliable means to safely remove decay heat, (2) to extend passive safety