WorldWideScience

Sample records for panel detector radiography

  1. Solid-state, flat-panel, digital radiography detectors and their physical imaging characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Cowen, A.R. [LXi Research, Academic Unit of Medical Physics, University of Leeds, West Yorkshire (United Kingdom)], E-mail: a.r.cowen@leeds.ac.uk; Kengyelics, S.M.; Davies, A.G. [LXi Research, Academic Unit of Medical Physics, University of Leeds, West Yorkshire (United Kingdom)

    2008-05-15

    Solid-state, digital radiography (DR) detectors, designed specifically for standard projection radiography, emerged just before the turn of the millennium. This new generation of digital image detector comprises a thin layer of x-ray absorptive material combined with an electronic active matrix array fabricated in a thin film of hydrogenated amorphous silicon (a-Si:H). DR detectors can offer both efficient (low-dose) x-ray image acquisition plus on-line readout of the latent image as electronic data. To date, solid-state, flat-panel, DR detectors have come in two principal designs, the indirect-conversion (x-ray scintillator-based) and the direct-conversion (x-ray photoconductor-based) types. This review describes the underlying principles and enabling technologies exploited by these designs of detector, and evaluates their physical imaging characteristics, comparing performance both against each other and computed radiography (CR). In standard projection radiography indirect conversion DR detectors currently offer superior physical image quality and dose efficiency compared with direct conversion DR and modern point-scan CR. These conclusions have been confirmed in the findings of clinical evaluations of DR detectors. Future trends in solid-state DR detector technologies are also briefly considered. Salient innovations include WiFi-enabled, portable DR detectors, improvements in x-ray absorber layers and developments in alternative electronic media to a-Si:H.

  2. Digital chest radiography with an amorphous silicon flat-panel-detector versus a storage-phosphor system: comparison of soft-copy images

    International Nuclear Information System (INIS)

    Lee, Hyun Ju; Im, Jung Gi; Goo, Jin Mo; Lee, Chang Hyun

    2006-01-01

    We compared the soft-copy images produced by an amorphous silicon flat-panel-detector system with the images produced by a storage-phosphor radiography system for their ability to visualize anatomic regions of the chest. Two chest radiologists independently analyzed 234 posteroanterior chest radiographs obtained from 78 patients on high-resolution liquid crystal display monitors (2560 x 2048 x 8 bits). In each patient, one radiograph was obtained with a storage-phosphor system, and two radiographs were obtained via amorphous silicon flat-panel-detector radiography with and without spatial frequency filtering. After randomizing the 234 images, the interpreters rated the visibility and radiographic quality of 11 different anatomic regions. Each image was ranked on a five-point scale (1 = not visualized, 2 = poor visualization, 3 = fair visualization, 4 = good visualization, and 5 = excellent visualization). The statistical difference between each system was determined using the Wilcoxon's signed rank test. The visibility of three anatomic regions (hilum, heart border and ribs), as determined by the chest radiologist with 14 years experience (ρ < 0.05) and the visibility of the thoracic spine, as determined by the chest radiologist with 8 years experience (ρ = 0.036), on the amorphous silicon flat-panel-detector radiography prior to spatial frequency filtering were significantly superior to that on the storage-phosphor radiography. The visibility of 11 anatomic regions, as determined by the chest radiologist with 14 years experience (ρ < 0.0001) and the visibility of five anatomic regions (unobscured lung, rib, proximal airway, thoracic spine and overall appearance), as determined by the chest radiologist with 8 years experience (ρ < 0.05), on the amorphous silicon flat-panel-detector radiography after spatial frequency filtering were significantly superior to that on the storage-phosphor radiography. The amorphous silicon flat-panel-detector system depicted the

  3. Digital chest radiography: flat-panel detectors or conventional radiographs

    International Nuclear Information System (INIS)

    Schaefer-Prokop, C.; Uffmann, M.; Sailer, J.; Kabalan, N.; Herold, C.; Prokop, M.

    2003-01-01

    Flat panel detectors are characterized by improved handling and increased dose efficiency. This allows for increasing of work flow efficiency and for reducing the exposure dose by about 50% compared to current systems with a sensitivity of 400. Whether the increased dose efficiency should be used to reduce acquisition dose or to increase image quality in the chest, will be shown by further clinical experience and will be also determined by the subjective preference of the radiologists. The decreased level of image noise opens new perspectives for image processing that way that elaborated multifrequency processing allows for optimizing the display of very small and low contrast structures that was so far limited by overlying image noise. Specialized applications of dual energy subtraction and temporal subtraction will also profit by the new detector technology and will be further driven forward in context with applications such as computed assisted diagnosis even though this is currently not yet broadly applied. Storage phosphor radiography still represents an important alternative technique based on its larger flexibility with respect to equipment configuration, its broader application options in intensive care and emergency radiology and due to economic reasons. These facts are further underlined by the fact that image quality also in storage phosphor radiography could be constantly increased by improving detector technology and image processing and consequently has a high standard. (orig.) [de

  4. Initial experiences in clinical application of the THORAX-FD: flat-panel detector radiography in thoracic diagnosis

    International Nuclear Information System (INIS)

    Herrmann, K.A.; Staebler, A.; Bonel, H.; Kulinna, C.; Holzknecht, N.; Reiser, M.F.; Geiger, B.; Boehm, S.; Maschke, M.

    2000-01-01

    The flat-panel detector closes the gap between radiography and the digital diagnostics equipment currently in use. In addition to the dose reduction that can be expected, the availability of diagnostic information in digital form enables the user to optimize the clinical workflow and to network radiography directly with a digital archiving and communication system. (orig.)

  5. Flat-panel detectors in x-ray diagnosis

    International Nuclear Information System (INIS)

    Spahn, M.; Heer, V.; Freytag, R.

    2003-01-01

    For all application segments X-ray systems with flat-panel detectors increasingly enter the market. In digital radiography, mammography and cardiologic angiography flat-panel detectors are already well established while they are made ready for market introduction in general angiography and fluoroscopy. Two flat-panel detector technologies are available. One technology is based on an indirect conversion process of X-rays while the other one uses a direct conversion method.For radiography and dynamic applications the indirect method provides substantial advantages, while the direct method has some benefits for mammography. In radiography and mammography flat-panel detectors lead to clear improvements with respect to workflow, image quality and dose reduction potentials. These improvements are fostered by the immediate availability of the image, the large dynamic range and the high sensitivity to X-rays. New applications and the use of complex image processing algorithms have the potential to enlarge the present diagnostic range of applications.Up to now, image intensifiers are still the well-established technology for angiography and fluoroscopy. Nevertheless flat-panel detectors begin to enter this field, especially in cardiologic angiography.Characteristics of flat-panel detectors such as the availability of distortion-free images, the excellent contrast resolution, the large dynamic range, the high sensitivity to X-rays and the usability in magnetic fields provide the basis for improved and new diagnostic and interventional methods. (orig.) [de

  6. Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging.

    Science.gov (United States)

    Tanaka, Rie

    2016-07-01

    Dynamic chest radiography is a flat-panel detector (FPD)-based functional X-ray imaging, which is performed as an additional examination in chest radiography. The large field of view (FOV) of FPDs permits real-time observation of the entire lungs and simultaneous right-and-left evaluation of diaphragm kinetics. Most importantly, dynamic chest radiography provides pulmonary ventilation and circulation findings as slight changes in pixel value even without the use of contrast media; the interpretation is challenging and crucial for a better understanding of pulmonary function. The basic concept was proposed in the 1980s; however, it was not realized until the 2010s because of technical limitations. Dynamic FPDs and advanced digital image processing played a key role for clinical application of dynamic chest radiography. Pulmonary ventilation and circulation can be quantified and visualized for the diagnosis of pulmonary diseases. Dynamic chest radiography can be deployed as a simple and rapid means of functional imaging in both routine and emergency medicine. Here, we focus on the evaluation of pulmonary ventilation and circulation. This review article describes the basic mechanism of imaging findings according to pulmonary/circulation physiology, followed by imaging procedures, analysis method, and diagnostic performance of dynamic chest radiography.

  7. The effect of dose reduction on image quality in digital radiography using a flat-panel detector: experimental study in rabbits

    International Nuclear Information System (INIS)

    Jung, Sung Il; Goo, Jin Mo; Lee, Hyun Ju; Moon, Woo Kyung; Lim, Kun Young; Cho, Gyung Goo; Kim, Ji Hoon; Im, Jung Gi; Choi, Jang Yong; Nam, Sang Hee

    2005-01-01

    To evaluate the effect of dose reduction on image quality in digital radiography using a flat-panel detector. Digital radiographs of 30 rabbits were obtained at two different dose levels (33.23 μGY for the standard dose group and 20.09 μGY for the reduced dose group). The amorphous selenium-based flat-panel detector system had a panel size of 7 x 8.5 inches, a matrix of 1280 x 1536 (pixels?), and a pixel pitch of 138 μm. Four observers evaluated the soft-copy images on a high-resolution video monitor (2560 x 2048 x 8 bits) in random order. The observers rated the visibility of 13 different anatomic structures on a 5-point scale, viz, the retrocardiac lung, subdiaphragmatic lung, heart border, diaphragmatic border, proximal airway, unobscured lung, liver border, kidney border, bowel gas, flank stripe, ribs, and vertebrae in the mediastinal and abdominal regions. Statistical significance was determined using Wilcoxon's signed rank test. There was no statistically significant difference in the visibility of the anatomic structures on digital radiography between the standard and reduced dose groups. Digital radiography using an amorphous selenium-based flat-panel detector can preserve the image quality, though the dose is reduced to 40% of the standard level

  8. The effect of dose reduction on image quality in digital radiography using a flat-panel detector: experimental study in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Sung Il; Goo, Jin Mo; Lee, Hyun Ju; Moon, Woo Kyung; Lim, Kun Young; Cho, Gyung Goo; Kim, Ji Hoon; Im, Jung Gi [Seoul National College of Medicine, Seoul (Korea, Republic of); Choi, Jang Yong; Nam, Sang Hee [Inje University, Seoul (Korea, Republic of)

    2005-07-15

    To evaluate the effect of dose reduction on image quality in digital radiography using a flat-panel detector. Digital radiographs of 30 rabbits were obtained at two different dose levels (33.23 {mu}GY for the standard dose group and 20.09 {mu}GY for the reduced dose group). The amorphous selenium-based flat-panel detector system had a panel size of 7 x 8.5 inches, a matrix of 1280 x 1536 (pixels?), and a pixel pitch of 138 {mu}m. Four observers evaluated the soft-copy images on a high-resolution video monitor (2560 x 2048 x 8 bits) in random order. The observers rated the visibility of 13 different anatomic structures on a 5-point scale, viz, the retrocardiac lung, subdiaphragmatic lung, heart border, diaphragmatic border, proximal airway, unobscured lung, liver border, kidney border, bowel gas, flank stripe, ribs, and vertebrae in the mediastinal and abdominal regions. Statistical significance was determined using Wilcoxon's signed rank test. There was no statistically significant difference in the visibility of the anatomic structures on digital radiography between the standard and reduced dose groups. Digital radiography using an amorphous selenium-based flat-panel detector can preserve the image quality, though the dose is reduced to 40% of the standard level.

  9. Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen

    International Nuclear Information System (INIS)

    Okamura, Terue; Tanaka, Saori; Koyama, Koichi; Norihumi, Nishida; Daikokuya, Hideo; Matsuoka, Toshiyuki; Yamada, Ryusaku; Kishimoto, Kenji; Hatagawa, Masakatsu; Kudoh, Hiroaki

    2002-01-01

    The aim of this clinical study was to compare the image quality of digital radiography using the new digital Bucky system based on a flat-panel detector with that of a conventional screen-film system for the skeletal structure and the abdomen. Fifty patients were examined using digital radiography with a flat-panel detector and screen-film systems, 25 for the skeletal structures and 25 for the abdomen. Six radiologists judged each paired image acquired under the same exposure parameters concerning three observation items for the bone and six items for the abdomen. Digital radiographic images for the bone were evaluated to be similar to screen-film images at the mean of 42.2%, to be superior at 50.2%, and to be inferior at 7.6%. Digital radiographic images for the abdomen were judged to be similar to screen-film images at the mean of 43.4%, superior at 52.4%, and inferior at 4.2%; thus, digital radiographic images were estimated to be either similar as or superior to screen-film images at over 92% for the bone and abdomen. On the statistical analysis, digital radiographic images were also judged to be preferred significantly in the most items for the bone and abdomen. In conclusion, the image quality of digital radiography with a flat-panel detector was superior to that of a screen-film system under the same exposure parameters, suggesting that dose reduction is possible with digital radiography. (orig.)

  10. Digital radiography with large-area flat-panel detectors

    International Nuclear Information System (INIS)

    Kotter, E.; Langer, M.

    2002-01-01

    Large-area flat-panel detectors with active readout mechanisms have been on the market for the past 2 years. This article describes different detector technologies. An important distinction is made between detectors with direct and those with indirect conversion of X-rays into electrical charges. Detectors with indirect conversion are built with unstructured or structured scintillators, the latter resulting in less lateral diffusion of emitted light. Some important qualities of flat-panel detectors are discussed. The first phantom and clinical studies published report an image quality at least comparable to that of screen-film systems and a potential for dose reduction. The available studies are summarised in this article. (orig.)

  11. Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System

    International Nuclear Information System (INIS)

    Jeong, Hoi Woun; Min, Jung Hwan; Kim, Jung Min; Park, Min Seok; Lee, Gaung Young

    2012-01-01

    The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

  12. Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hoi Woun [Dept. of Radiological Science, Baekseok Culture University, Seoul (Korea, Republic of); Min, Jung Hwan [Dept. of Radiological Technology, Shingu University, Seongnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Science, Korea University, Health Science College, Seoul (Korea, Republic of); Park, Min Seok [Korea Institue of Radiological and Medical Sicences, Research Institute of Radiologycal and Medical Sciences, Seoul (Korea, Republic of); Lee, Gaung Young [National Institute of Food and Drug Safety Evaluation, Seoul (Korea, Republic of)

    2012-06-15

    The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

  13. Feasibility study of flexible flat-panel X-ray detectors for digital radiography

    International Nuclear Information System (INIS)

    Joe, Ok La; Yun, Seung Man; Kim, Ho Kyung

    2010-01-01

    Flexible flat-panel detectors (FPDs), which utilize both organic photodiode (OPD) and organic thin-film transistor (OTFT) technologies, are recently concerned in digital radiography. The flexible FPD has several potential advantages, such as high accessibility to patient, avoidance of geometrical burr due to the oblique angle incidence of X-ray, great reduction in manufacturing cost due to jet-printing. At once, The OPD/OTFT arrays were fabricated by jet-printing techniques, mechanical robustness due to plastic substrates, and so on. In this study, we have investigated the feasibility of flexible FPD by comparing theoretical detective quantum efficiency (DQE) with that of the conventional amorphous silicon-based FPD. We chose copper phthalocyanine-fullerene (CuPc-C60) organic materials for the construction of the flexible FPD. DQE was calculated by the linear-systems transfer theory

  14. On site evaluation of three flat panel detectors for digital radiography

    International Nuclear Information System (INIS)

    Borasi, Giovanni; Nitrosi, Andrea; Ferrari, Paolo; Tassoni, Davide

    2003-01-01

    During a tender we evaluated the image performance of three commercially available active matrix flat panel imagers (AMFPI) for general radiography, one based on direct detection method (Se photoconductor) the other two on indirect detection method (CsI phosphor). Basic image quality parameters (MTF, NNPS, DQE) were evaluated with particular attention to dose and energy dependence. As it is known, presampling modulation transfer function (MTF) of selenium based detector is very high (at 70 kV, 2 cycles/mm, 2.5 μGy, about 0.80). Indirect detection panels exhibit a comparable (lower) resolution (at 70 kV, 2 cycles/mm, 2.5 μGy, MTF is about 0.34 for both the systems analyzed) and a more pronounced energy and dose dependence could also be noted in one of them. As a consequence of the very high resolution, the normalized noise power spectrum (NNPS) of the direct system is substantially flat, very similar to a white noise. Considering that the sensitive layer of all detectors is the same (0.5 mm), the relatively higher NNPS values are related to selenium absorption properties (lower Z respect to CsI:Tl) and detector inherent noise. NNPSs of the other systems, at low frequencies, are comparable but the frequency dependence is significantly different. At 70 kV, 2.5 μGy, 0.5 cycles/mm detective quantum efficiency (DQE) is about 0.35 for the direct detection system, and about the same (0.6) for the indirect ones. The combined effect of additive and multiplicative noise components makes DQE dependence on dose not monotonic. DQE present a maximum for an intermediate exposure. This complex behavior may be useful to characterize the systems in terms of the monodimensional integral over the frequency of DQE (IDQE). Both visual contrast-detail experiment and the direct evaluation of the signal-to-noise ratio confirmed, at least in a qualitative way, the system performances predicted by IDQE

  15. Extra-oral dental radiography for disaster victims using a flat panel X-ray detector and a hand-held X-ray generator.

    Science.gov (United States)

    Ohtani, M; Oshima, T; Mimasaka, S

    2017-12-01

    Forensic odontologists commonly incise the skin for post-mortem dental examinations when it is difficult to open the victim's mouth. However, it is prohibited by law to incise dead bodies without permission in Japan. Therefore, we attempted using extra-oral dental radiography, using a digital X-ray equipment with rechargeable batteries, to overcome this restriction. A phantom was placed in the prone position on a table, and three plain dental radiographs were used per case: "lateral oblique radiographs" for left and right posterior teeth and a "contact radiograph" for anterior teeth were taken using a flat panel X-ray detector and a hand-held X-ray generator. The resolving power of the images was measured by a resolution test chart, and the scattered X-ray dose was measured using an ionization chamber-type survey meter. The resolving power of the flat panel X-ray detector was 3.0 lp/mm, which was less than that of intra-oral dental methods, but the three extra-oral plain dental radiographs provided the overall dental information from outside of the mouth, and this approach was less time-consuming. In addition, the higher dose of scattered X-rays was laterally distributed, but the dose per case was much less than that of intra-oral dental radiographs. Extra-oral plain dental radiography can be used for disaster victim identification by dental methods even when it is difficult to open the mouth. Portable and rechargeable devices, such as a flat panel X-ray detector and a hand-held X-ray generator, are convenient to bring and use anywhere, even at a disaster scene lacking electricity and water.

  16. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    Energy Technology Data Exchange (ETDEWEB)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-04-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  17. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    International Nuclear Information System (INIS)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-01-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  18. Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Liu Xinming; Lai Chaojen; Chen Lingyun; Han Tao; Zhong Yuncheng; Shen Youtao; Wang Tianpeng; Shaw, Chris C [Department of Imaging Physics, Digital Imaging Research Laboratory, University of Texas M. D. Anderson Cancer Center, Houston, TX 77030-4009 (United States)], E-mail: xliu@di.mdacc.tmc.edu

    2009-11-21

    It is well recognized in projection radiography that low-contrast detectability suffers in heavily attenuating regions due to excessively low x-ray fluence to the image receptor and higher noise levels. Exposure equalization can improve image quality by increasing the x-ray exposure to heavily attenuating regions, resulting in a more uniform distribution of exposure to the detector. Image quality is also expected to be improved by using the slot-scan geometry to reject scattered radiation effectively without degrading primary x-rays. This paper describes the design of a prototype scan equalization digital radiography (SEDR) system implemented with an amorphous silicon (a-Si) thin-film transistor (TFT) array-based flat-panel detector. With this system, slot-scan geometry with alternate line erasure and readout (ALER) technique was used to achieve scatter rejection. A seven-segment beam height modulator assembly was mounted onto the fore collimator to regulate exposure regionally for chest radiography. The beam modulator assembly, consisting of micro linear motors, lead screw cartridge with lead (Pb) beam blockers attached, position feedback sensors and motor driver circuitry, has been tested and found to have an acceptable response for exposure equalization in chest radiography. An anthropomorphic chest phantom was imaged in the posterior-anterior (PA) view under clinical conditions. Scatter component, primary x-rays, scatter-to-primary ratios (SPRs) and primary signal-to-noise ratios (PSNRs) were measured in the SEDR images to evaluate the rejection and redistribution of scattered radiation, and compared with those for conventional full-field imaging with and without anti-scatter grid methods. SPR reduction ratios (SPRRRs, defined as the differences between the non-grid full-field SPRs and the reduced SPRs divided by the former) yielded approximately 59% for the full-field imaging with grid and 82% for the SEDR technique in the lungs, and 77% for the full

  19. Present and future of flat panel detectors in the world

    International Nuclear Information System (INIS)

    Inamura, Kiyonari

    2002-01-01

    Present status of development of flat panel detectors and their clinical application in the world have been surveyed, and future trends are also explored especially in the field of material researches and methods of manufacturing. Also the importance of role of medical physicists on user side is described because characteristic physics measurement of a detector assembly is unavoidable and essential in quality assurance in clinical routine and acceptance test in hospitals. Even though physics measurements and clinical evaluations on flat panel detectors have shown remarkable progress and advances in these several years, future problems of cost down in manufacturing and quality assurance to prevent individual differences between detector assemblies must be resolved. Results of evaluation in mammography, chest radiography, fluoroscopy for cardiovascular examination, bone tumor examination and radiotherapy application indicate that flat panel detectors are future promising materials. Their systematic operation is contributing to heighten accuracy of image examinations and preciseness of radiation therapy. Encouragement to medical physicists relevant to flat panel detectors is also raised in this paper. (author)

  20. Use and imaging performance of CMOS flat panel imager with LiF/ZnS(Ag) and Gadox scintillation screens for neutron radiography

    Science.gov (United States)

    Cha, B. K.; kim, J. Y.; Kim, T. J.; Sim, C.; Cho, G.; Lee, D. H.; Seo, C.-W.; Jeon, S.; Huh, Y.

    2011-01-01

    In digital neutron radiography system, a thermal neutron imaging detector based on neutron-sensitive scintillating screens with CMOS(complementary metal oxide semiconductor) flat panel imager is introduced for non-destructive testing (NDT) application. Recently, large area CMOS APS (active-pixel sensor) in conjunction with scintillation films has been widely used in many digital X-ray imaging applications. Instead of typical imaging detectors such as image plates, cooled-CCD cameras and amorphous silicon flat panel detectors in combination with scintillation screens, we tried to apply a scintillator-based CMOS APS to neutron imaging detection systems for high resolution neutron radiography. In this work, two major Gd2O2S:Tb and 6LiF/ZnS:Ag scintillation screens with various thickness were fabricated by a screen printing method. These neutron converter screens consist of a dispersion of Gd2O2S:Tb and 6LiF/ZnS:Ag scintillating particles in acrylic binder. These scintillating screens coupled-CMOS flat panel imager with 25x50mm2 active area and 48μm pixel pitch was used for neutron radiography. Thermal neutron flux with 6x106n/cm2/s was utilized at the NRF facility of HANARO in KAERI. The neutron imaging characterization of the used detector was investigated in terms of relative light output, linearity and spatial resolution in detail. The experimental results of scintillating screen-based CMOS flat panel detectors demonstrate possibility of high sensitive and high spatial resolution imaging in neutron radiography system.

  1. Flat panel detectors - closing the (digital) gap in chest and skeletal radiology

    International Nuclear Information System (INIS)

    Reiff, Kurt J.

    1999-01-01

    In the radiological department today the majority of all X-ray procedures on chest and skeletal radiography is performed with classical film-screen-systems. Using digital luminescence radiography (DLR or CR, which stands for Computed Radiography) as a technique has shown a way to replace this 100-year-old procedure of doing general radiography work by acquiring the X-rays digitally via phosphor screens, but this approach has faced criticism from lots of radiologists world wide and therefore has not been widely accepted except in the intensive care environment. A new technology is now rising based on the use of so called flat panel X-ray (FD) detectors. Semi-conducting material detects the X-rays in digital form directly and creates an instantaneous image for display, distribution and diagnosis. This ability combined with a large field of view and -- compared to existing methods -- excellent detective quantum efficiency represents a revolutionary step for chest and skeletal radiography and will put basic X-ray-work back into the focus of radiological solutions. This paper will explain the basic technology of flat panel detectors, possible system solutions based on this new technology, aspects of the user interface influencing the system utilization and versatility as well as the possibility to redefine the patient examination process for chest and skeletal radiography. Furthermore the author discusses limitations for the first released systems, upgrades for the installed base and possible scenarios for the future. e.g. fluoroscopy or angiography application

  2. Portable low-cost flat panel detectors for real-time digital radiography

    International Nuclear Information System (INIS)

    Iovea, Mihai; Neagu, Marian; Stefanescu, Bogdan; Mateiasi, Gabriela; Porosnicu, Ioana; Angheluta, Elena

    2015-01-01

    The X-ray inspection is one of the most common used non-destructive testing methods in industry applications, but for the portable X-ray digital solution are not so many accessible, low-cost and versatile detection devices. The efficiency of a non-destructive X-ray portable device is represented by the quality of digital images, by its low acquisition time combined with a high resolution, in condition of low noise and at an affordable cost. The paper presents two X-ray portable imaging systems developed by us, suitable also for aerospace NDT applications, which are also very versatile for being easily adapted for other fields that requires mobile solutions. The first device described in the paper represent a portable large-size (210 mm X 550 mm) and high-resolution (27/54 microns) flat panel detector based on linear translation of a X-Ray TDI detector, destined for various components/parts real-time transmission measurements. The second system it is also a flat panel detectors, with a size of 510 mm X 610 mm, with the detector size from 0.2 mm until 1.5 mm, which can operate by applying the dual-energy method, very useful for discriminating materials by evaluating their Atomic effective number. The high resolution and low-cost of this flat-panels widens their applicability by covering large requirements, from identifying unwanted materials within a structure until detection of very thin cracks in complex components.

  3. Portable low-cost flat panel detectors for real-time digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Iovea, Mihai; Neagu, Marian; Stefanescu, Bogdan; Mateiasi, Gabriela; Porosnicu, Ioana; Angheluta, Elena [Accent Pro 2000 S.R.L., Bucharest (Romania)

    2015-07-01

    The X-ray inspection is one of the most common used non-destructive testing methods in industry applications, but for the portable X-ray digital solution are not so many accessible, low-cost and versatile detection devices. The efficiency of a non-destructive X-ray portable device is represented by the quality of digital images, by its low acquisition time combined with a high resolution, in condition of low noise and at an affordable cost. The paper presents two X-ray portable imaging systems developed by us, suitable also for aerospace NDT applications, which are also very versatile for being easily adapted for other fields that requires mobile solutions. The first device described in the paper represent a portable large-size (210 mm X 550 mm) and high-resolution (27/54 microns) flat panel detector based on linear translation of a X-Ray TDI detector, destined for various components/parts real-time transmission measurements. The second system it is also a flat panel detectors, with a size of 510 mm X 610 mm, with the detector size from 0.2 mm until 1.5 mm, which can operate by applying the dual-energy method, very useful for discriminating materials by evaluating their Atomic effective number. The high resolution and low-cost of this flat-panels widens their applicability by covering large requirements, from identifying unwanted materials within a structure until detection of very thin cracks in complex components.

  4. Evaluation of a flat-panel detector system

    International Nuclear Information System (INIS)

    Sato, Masami; Eguchi, Yoichi; Yamada, Kinichi; Kaga, Yuji; Endo, Yutaka; Yamazaki, Tatsuya

    2001-01-01

    We evaluated the imaging performance of a flat-panel detector digital radiography system (CXDI-11 X-ray Digital Camera, Canon Inc.) and a computed radiography system (FCR9000C-HQ, Fuji Film). The characteristics of the two detectors and of the overall systems were compared. This included evaluation and comparison of the fundamental physical characteristics, including x-ray response curve, modulation transfer function (MTF), Wiener spectra, noise-equivalent quanta, and x-ray tube voltage-dependent detector response. Overall system performance was evaluated using receiver operating characteristic (ROC) analysis. The results of the study showed that the dynamic range of the CXDI-11 measured relative to the input x-ray flux was 10 3 , similar to that of the FCR9000C-HQ. Both systems showed similar final MTFs, although the pre-sampling MTF of the CXDI-11 was better than that of the FCR9000C-HQ. Noise analysis, based on noise-equivalent quanta and Wiener spectra, showed that for normal exposure conditions the CXDI-11 had superior performance. With both systems, x-ray response (system output/incident x-ray exposure) increased with increasing x-ray tube voltage. ROC analysis indicated that the CXDI-11 was superior in overall performance. (author)

  5. Digital radiography of the skeleton using a large-area detector based on amorphous silicon technology: Image quality and potential for dose reduction in comparison with screen-film radiography

    International Nuclear Information System (INIS)

    Volk, M.; Strotzer, M.; Holzkneckt, N.; Manke, C.; Lenhart, M.; Gmeinwieser, J.; Link, J.; Reiser, M.; Feuerback, S.

    2000-01-01

    AIM: The purpose of this study was to evaluate a large-area, flat-panel X-ray detector (FD), based on caesium-iodide (CsI) and amorphous silicon (a-Si) with respect to skeletal radiography. Conventional images were compared with digital radiographs using identical and reduced radiation doses. MATERIALS AND METHODS: Thirty consecutive patients were studied prospectively using conventional screen-film radiography (SFR; detector dose 2.5 μGy). Digital images were taken from the same patients with detector doses of 2.5, 1.25 and 0.625 μGy, respectively. The active-matrix detector had a panel size of 43 x 43 cm, a matrix of 3 x 3K, and a pixel size of 143 μm. All hard copies were presented in a random order to eight independent observers, who rated image quality according to subjective quality criteria. Results were assessed for significance using the Student's t -test (confidence level 95%). RESULTS: A statistically significant preference for digital over conventional images was revealed for all quality criteria, except for over-exposure (detector dose 2.5 μGy). Digital images with a 50% dose showed a small, statistically not significant, inferiority compared with SFR. The FD-technique was significantly inferior to SFR at 75% dose reduction regarding bone cortex and trabecula, contrast and overall impression. No statistically significant differences were found with regard to over- and under-exposure and soft tissue presentation. CONCLUSION: Amorphous silicon-based digital radiography yields good image quality. The potential for dose reduction depends on the clinical query. Volk, M. (2000)

  6. Pediatric radiation dose management in digital radiography

    International Nuclear Information System (INIS)

    Neitzel, U.

    2004-01-01

    Direct digital radiography (DR) systems based on flat-panel detectors offer improved dose management in pediatric radiography. Integration of X-ray generation and detection in one computer-controlled system provides better control and monitoring

  7. Direct detector radiography versus dual reading computed radiography: feasibility of dose reduction in chest radiography

    International Nuclear Information System (INIS)

    Gruber, Michael; Uffmann, Martin; Weber, Michael; Balassy, Csilla; Schaefer-Prokop, Cornelia; Prokop, Mathias

    2006-01-01

    The image quality of dual-reading computed radiography and dose-reduced direct radiography of the chest was compared in a clinical setting. The study group consisted of 50 patients that underwent three posteroanterior chest radiographs within minutes, one image obtained with a dual read-out computed radiography system (CR; Fuji 5501) at regular dose and two images with a flat panel direct detector unit (DR; Diagnost, Philips). The DR images were obtained with the same and with 50% of the dose used for the CR images. Images were evaluated in a blinded side-by-side comparison. Eight radiologists ranked the visually perceivable difference in image quality using a three-point scale. Then, three radiologists scored the visibility of anatomic landmarks in low and high attenuation areas and image noise. Statistical analysis was based on Friedman tests and Wilcoxon rank sum tests at a significance level of P<0.05. DR was judged superior to CR for the delineation of structures in high attenuation areas of the mediastinum even when obtained with 50% less dose (P<0.001). The visibility of most pulmonary structures was judged equivalent with both techniques, regardless of acquisition dose and speed level. Scores for image noise were lower for DR compared with CR, with the exception of DR obtained at a reduced dose. Thus, in this clinical preference study, DR was equivalent or even superior to the most modern dual read-out CR, even when obtained with 50% dose. A further dose reduction does not appear to be feasible for DR without significant loss of image quality. (orig.)

  8. Digital radiography is promising in industrial testing

    International Nuclear Information System (INIS)

    Del Fabbro, F.

    2015-01-01

    Digital radiography has recently entered the industrial world as a tool for non-destructive testing. There are 3 types of digital radiography: computed radiography (CR), direct radiography (DR) and computed tomography (CT). In computed radiography, traditional silver-halide films are replaced by photostimulable phosphor imaging plates that are activated through laser scanning and digitized. Direct radiography uses a flat panel detector (FPD) composed of X-ray detectors that performs an immediate digital conversion of the image that can be read by a computer. DR is a perfect tool for industrial testing but the fragility of the FPD panels reduces its uses. Computed tomography is based on the principle of DR to get data corresponding to successive cross-section images of the object. These data are processed by a software to get a 3-dimensional image of the object. CT was first developed for medical use but requires some improvement to become more accurate, faster, particularly for big objects. In recent years DR has enjoyed the highest growth rate in digital radiography. (A.C.)

  9. Digital radiography with a large-scale electronic flat-panel detector vs screen-film radiography: observer preference in clinical skeletal diagnostics

    International Nuclear Information System (INIS)

    Hamers, S.; Freyschmidt, J.; Neitzel, U.

    2001-01-01

    The imaging performance of a recently developed digital flat-panel detector system was compared with conventional screen-film imaging in an observer preference study. In total, 34 image pairs of various regions of the skeleton were obtained in 24 patients; 30 image pairs were included in the study. The conventional images were acquired with 250- and 400-speed screen-film combinations, using the standard technique of our department. Within hours, the digital images were obtained using identical exposure parameters. The digital system employed a large-area (43 x 43 cm) flat-panel detector based on amorphous silicon (Trixell Pixium 4600), integrated in a Bucky table. Six radiologists independently evaluated the image pairs with respect to image latitude, soft tissue rendition, rendition of the periosteal and enosteal border of cortical bone, rendition of cancellous bone and the visibility of potentially present pathological changes, using a subjective five-point scale. The digital images were rated significantly (p=0.001) better than the screen-film images with respect to soft tissue rendition and image latitude. Also the rendition of the cancellous bone and the periosteal and enosteal border of the cortical bone was rated significantly (p=0.05) better for the flat-panel detector. The visibility of pathological lesions was equivalent; only large-area sclerotic lesions (n=2) were seen superiorly on screen-film images. The new digital flat-panel detector based on amorphous silicon appears to be at least equivalent to conventional screen-film combinations for skeletal examinations, and in most respects even superior. (orig.)

  10. Development of CT and 3D-CT Using Flat Panel Detector Based Real-Time Digital Radiography System

    International Nuclear Information System (INIS)

    Ravindran, V. R.; Sreelakshmi, C.; Vibin

    2008-01-01

    The application of Digital Radiography in the Nondestructive Evaluation (NDE) of space vehicle components is a recent development in India. A Real-time DR system based on amorphous silicon Flat Panel Detector has been developed for the NDE of solid rocket motors at Rocket Propellant Plant of VSSC in a few years back. The technique has been successfully established for the nondestructive evaluation of solid rocket motors. The DR images recorded for a few solid rocket specimens are presented in the paper. The Real-time DR system is capable of generating sufficient digital X-ray image data with object rotation for the CT image reconstruction. In this paper the indigenous development of CT imaging based on the Realtime DR system for solid rocket motor is presented. Studies are also carried out to generate 3D-CT image from a set of adjacent CT images of the rocket motor. The capability of revealing the spatial location and characterisation of defect is demonstrated by the CT and 3D-CT images generated.

  11. A method of detector correction for cosmic ray muon radiography

    International Nuclear Information System (INIS)

    Liu Yuanyuan; Zhao Ziran; Chen Zhiqiang; Zhang Li; Wang Zhentian

    2008-01-01

    Cosmic ray muon radiography which has good penetrability and sensitivity to high-Z materials is an effective way for detecting shielded nuclear materials. The problem of data correction is one of the key points of muon radiography technique. Because of the influence of environmental background, environmental yawp and error of detectors, the raw data can not be used directly. If we used the raw data as the usable data to reconstruct without any corrections, it would turn up terrible artifacts. Based on the characteristics of the muon radiography system, aimed at the error of detectors, this paper proposes a method of detector correction. The simulation experiments demonstrate that this method can effectively correct the error produced by detectors. Therefore, we can say that it does a further step to let the technique of cosmic muon radiography into out real life. (authors)

  12. Digital radiography: Present detectors and future developments

    International Nuclear Information System (INIS)

    Perez-Mendez, V.

    1990-08-01

    Present detectors for digital radiography are of two classes: real time detectors and storage (non real time) types. Present real time detectors consist of image intensifier tubes with an internal cesium iodide layer x-ray converter. Non real time detectors involve linear sweep arrays or storage detectors such as film. Future detectors discussed here can be of both types utilizing new technologies such as hydrogenated amorphous silicon photodiode arrays coupled to thin film transistor arrays. 17 refs., 10 figs

  13. Defective pixel map creation based on wavelet analysis in digital radiography detectors

    International Nuclear Information System (INIS)

    Park, Chun Joo; Lee, Hyoung Koo; Song, William Y.; Achterkirchen, Thorsten Graeve; Kim, Ho Kyung

    2011-01-01

    The application of digital radiography detectors has attracted increasing attention in both medicine and industry. Since the imaging detectors are fabricated by semiconductor manufacturing process over large areas, defective pixels in the detectors are unavoidable. Moreover, the radiation damage due to the routine use of the detectors progressively increases the density of defective pixels. In this study, we present a method of identifying defective pixels in digital radiography detectors based on wavelet analysis. Artifacts generated due to wavelet transformations have been prevented by an additional local threshold method. The proposed method was applied to a sample digital radiography and the result was promising. The proposed method uses a single pair of dark and white images and does not require them to be corrected in gain-and-offset properties. This method will be helpful for the reliable use of digital radiography detectors through the working lifetime.

  14. Synchrotron applications of an amorphous silicon flat-panel detector

    International Nuclear Information System (INIS)

    Lee, J. H.; Can Aydiner, C.; Almer, J.; Bernier, J.; Chapman, K. W.; Chupas, P. J.; Haeffner, D.; Kump, K.; Lee, P. L.; Lienert, U.; Miceli, A.; Vera, G.; LANL; GE Healthcare

    2008-01-01

    A GE Revolution 41RT flat-panel detector (GE 41RT) from GE Healthcare (GE) has been in operation at the Advanced Photon Source for over two years. The detector has an active area of 41 cm x 41 cm with 200 (micro)m x 200 (micro)m pixel size. The nominal working photon energy is around 80 keV. The physical set-up and utility software of the detector system are discussed in this article. The linearity of the detector response was measured at 80.7 keV. The memory effect of the detector element, called lag, was also measured at different exposure times and gain settings. The modulation transfer function was measured in terms of the line-spread function using a 25 (micro)m x 1 cm tungsten slit. The background (dark) signal, the signal that the detector will carry without exposure to X-rays, was measured at three different gain settings and with exposure times of 1 ms to 15 s. The radial geometric flatness of the sensor panel was measured using the diffraction pattern from a CeO 2 powder standard. The large active area and fast data-capturing rate, i.e. 8 frames s -1 in radiography mode, 30 frames s -1 in fluoroscopy mode, make the GE 41RT one of a kind and very versatile in synchrotron diffraction. The loading behavior of a Cu/Nb multilayer material is used to demonstrate the use of the detector in a strain-stress experiment. Data from the measurement of various samples, amorphous SiO 2 in particular, are presented to show the detector effectiveness in pair distribution function measurements

  15. High resolution radiography of ambers with pixel detectors

    Czech Academy of Sciences Publication Activity Database

    Dammer, J.; Weyda, F.; Beneš, J.; Sopko, V.; Jandejsek, I.; Pflegerová, Jitka

    2013-01-01

    Roč. 8, č. 3 (2013), C03024 ISSN 1748-0221. [Conference: International Workshop on Radiation Imaging Detectors /14./. Figueira da Foz, 01.07.2012-05.07.2012] Grant - others:GA ČR(CZ) GA103/09/2101; GA Mšk(CZ) LA08032 Program:GA; LA Institutional support: RVO:60077344 Keywords : X-ray detectors * Inspection with x-rays * X-ray radiography and digital radiography (DR) Subject RIV: EA - Cell Biology Impact factor: 1.526, year: 2013 http://iopscience.iop.org/1748-0221/8/03/C03024/

  16. Digital radiography detectors - A technical overview: Part 1

    International Nuclear Information System (INIS)

    Lanca, Luis; Silva, Augusto

    2009-01-01

    During the last two decades screen-film (SF) systems have been replaced by digital X-ray systems. The advent of digital technologies brought a number of digital solutions based on different detector and readout technologies. Improvements in technology allowed the development of new digital technologies for projection radiography such as computed radiography (CR) and digital radiography (DR). The large number of scientific papers concerning digital X-ray systems that have been published over the last 25 years indicates the relevance of these technologies in healthcare. There are important differences among different detector technologies that may affect system performance and image quality for diagnostic purposes. Radiographers are expected to have an effective understanding of digital X-ray technologies and a high level of knowledge and awareness concerning the capabilities of these systems. Patient safety and reliable diagnostic information are intrinsically linked to these factors. In this review article - which is the first of two parts - a global overview of the digital radiography systems (both CR and DR) currently available for clinical practice is provided

  17. The MU-RAY detector for muon radiography of volcanoes

    Energy Technology Data Exchange (ETDEWEB)

    Anastasio, A. [INFN-Napoli (Italy); Ambrosino, F. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); Basta, D. [INFN-Napoli (Italy); Bonechi, L. [Università degli Studi di Firenze, Firenze (Italy); INFN-Firenze (Italy); Brianzi, M. [Università degli Studi di Firenze, Firenze (Italy); Bross, A. [Fermilab (United States); Callier, S. [LAL, Orsay (France); Caputo, A. [INGV Osservatorio Vesuviano, Napoli (Italy); Ciaranfi, R. [INFN-Firenze (Italy); Cimmino, L. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); D' Alessandro, R. [Università degli Studi di Firenze, Firenze (Italy); INFN-Firenze (Italy); D' Auria, L. [INGV Osservatorio Vesuviano, Napoli (Italy); La Taille, C. de [LAL, Orsay (France); Energico, S. [CNR- SPIN, Napoli (Italy); INFN-Napoli (Italy); Garufi, F. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); Giudicepietro, F. [INGV Osservatorio Vesuviano, Napoli (Italy); Lauria, A. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); Macedonio, G.; Martini, M. [INGV Osservatorio Vesuviano, Napoli (Italy); Masone, V. [Università Federico II, Napoli (Italy); and others

    2013-12-21

    The MU-RAY detector has been designed to perform muon radiography of volcanoes. The possible use on the field introduces several constraints. First the electric power consumption must be reduced to the minimum, so that the detector can be solar-powered. Moreover it must be robust and transportable, for what concerns the front-end electronics and data acquisition. A 1 m{sup 2} prototype has been constructed and is taking data at Mt. Vesuvius. The detector consists of modules of 32 scintillator bars with wave length shifting fibers and silicon photomultiplier read-out. A dedicated front-end electronics has been developed, based on the SPIROC ASIC. An introduction to muon radiography principles, the MU-RAY detector description and results obtained in laboratory will be presented.

  18. Detection of small pulmonary nodules on chest radiographs: efficacy of dual-energy subtraction technique using flat-panel detector chest radiography

    International Nuclear Information System (INIS)

    Oda, S.; Awai, K.; Funama, Y.; Utsunomiya, D.; Yanaga, Y.; Kawanaka, K.; Nakaura, T.; Hirai, T.; Murakami, R.; Nomori, H.; Yamashita, Y.

    2010-01-01

    Aim: To investigate the effect of a double-exposure dual-energy subtraction (DES) technique on the diagnostic performance of radiologists detecting small pulmonary nodules on flat-panel detector (FPD) chest radiographs. Materials and methods: Using FPD radiography 41 sets of chest radiographs were obtained from 26 patients with pulmonary nodules measuring ≤20 mm and from 15 normal participants. Each dataset included standard and corresponding DES images. There were six non-solid, 10 part-solid, and 10 solid nodules. The mean size of the 26 nodules was 15 ± 4.8 mm. Receiver operating characteristic (ROC) analysis was performed to compare the performance of the eight board-certified radiologists. Results: For the eight radiologists, the mean value of the area under the ROC curve (AUC) without and with DES images was 0.62 ± 0.05 and 0.68 ± 0.05, respectively; the difference was statistically significant (p = 0.02). For part-solid nodules, the difference of the mean AUC value was statistically significant (AUC = 0.61 ± 0.07 versus 0.69 ± 0.05; p < 0.01); for non-solid nodules it was not (AUC = 0.62 ± 0.1 versus 0.61 ± 0.09; p = 0.73), and for solid nodules it was not (AUC = 0.75 ± 0.1 versus 0.78 ± 0.08; p = 0.23). For nodules with overlapping bone shadows, the difference of the mean AUC value was statistically significant (p = 0.03), for nodules without overlapping, it was not (p = 0.26). Conclusion: Use of a double-exposure DES technique at FPD chest radiography significantly improved the diagnostic performance of radiologists to detect small pulmonary nodules.

  19. Digital radiography in NDT applications

    International Nuclear Information System (INIS)

    Deprins, E.

    2004-01-01

    A lot of film radiography could be replaced by today's technologies in the field of digital radiography. Only few of these applications have indeed replaced film. The choice to go digital depends on cost, quality requirement, workflow and throughput. Digital images offer a lot of advantages in terms of image manipulation and workflow. But despite the many advantages, a lot of considerations are needed before someone can decide to convert his organization from conventional to digital radiography. This paper gives an overview of all different modalities that can be used in digital radiography with today's technologies, together with the experiences of the pioneers of digital radiography. Film Scanning, Computed Radiography and Digital Radiography by using of different kinds of flat panel detectors all have their specific application fields and customers. What is the status of the technology today, which advantages brings digital radiography, and which are the limitations radiographers have to consider when replacing film by digital systems. (author)

  20. Optimization of dual-energy subtraction chest radiography by use of a direct-conversion flat-panel detector system.

    Science.gov (United States)

    Fukao, Mari; Kawamoto, Kiyosumi; Matsuzawa, Hiroaki; Honda, Osamu; Iwaki, Takeshi; Doi, Tsukasa

    2015-01-01

    We aimed to optimize the exposure conditions in the acquisition of soft-tissue images using dual-energy subtraction chest radiography with a direct-conversion flat-panel detector system. Two separate chest images were acquired at high- and low-energy exposures with standard or thick chest phantoms. The high-energy exposure was fixed at 120 kVp with the use of an auto-exposure control technique. For the low-energy exposure, the tube voltages and entrance surface doses ranged 40-80 kVp and 20-100 % of the dose required for high-energy exposure, respectively. Further, a repetitive processing algorithm was used for reduction of the image noise generated by the subtraction process. Seven radiology technicians ranked soft-tissue images, and these results were analyzed using the normalized-rank method. Images acquired at 60 kVp were of acceptable quality regardless of the entrance surface dose and phantom size. Using a repetitive processing algorithm, the minimum acceptable doses were reduced from 75 to 40 % for the standard phantom and to 50 % for the thick phantom. We determined that the optimum low-energy exposure was 60 kVp at 50 % of the dose required for the high-energy exposure. This allowed the simultaneous acquisition of standard radiographs and soft-tissue images at 1.5 times the dose required for a standard radiograph, which is significantly lower than the values reported previously.

  1. Digital radiography of the chest in pediatric patients

    International Nuclear Information System (INIS)

    Puig, S.

    2003-01-01

    The hopes placed in digital radiography have been fulfilled only partly in pediatric radiology. Specifically, the option of gaining reduced radiation exposure in combination with a similar or even improved image quality was hard to realize. The only portable digital system available for a long time were storage phosphors which were disadvantaged by an extremely limited dose-quantum-efficiency (DQE) in comparison to digital flat panel detectors. New developments and the introduction of the dual-reading system led to image qualities comparable to film-screen-systems with high resolution and achievable without dose increase, sometimes even with dose reduction. A study using an animal model suggests that these systems can even be used in preterm infants with very low birth weights. A new portable flat panel detector by Canon may improve digital chest radiography in pediatric patients. (orig.) [de

  2. Proton Radiography: Cross Section Measurement and Detector Development

    International Nuclear Information System (INIS)

    Longo, Michael J.

    2007-01-01

    Proton radiography offers significant advantages over conventional X-ray radiography, including the capability of looking into thick, dense materials, better contrast for a wide range of materials, sensitivity to different materials of similar density, and better resolution because of the ability to focus beams. In order to achieve this capability it is crucial to understand the background due to neutrons and photons and to develop techniques to reduce it to tolerable levels. The physics goal of this project is to measure forward production of neutrons and photons produced by high-energy proton beams striking a variety of targets. This work is being carried out in conjunction with the Fermilab Experiment 907 (MIPP) collaboration including physicists from Lawrence Livermore Laboratory. Our group is responsible for the E907 forward neutron/photon calorimeters. These are the only detectors in the experiment that provide information on neutrons and photons. We are taking a leading role in obtaining and analyzing the for-ward production data and in developing an optimal detector for proton radiography. With the support of our Stewardship Science Academic Alliances grant, we were able to design, build, and commission the calorimeters on budget and ahead of schedule. E-907 officially started physics running at Fermilab in January 2005, and data taking continued through February 2006. Data were taken on a range of targets, from liquid hydrogen to uranium, at beam energies from 5 GeV/c to 120 GeV/c. The analysis of the data is challenging because data from many different detector systems must be understood and merged and over 31 million events were accumulated. Our recent efforts have been devoted to the calibration of the neutron and photon detectors, to track and shower reconstruction, identification of forward-going neutrons, and simulation of the calorimeters in a Monte Carlo. Reconstruction of the data with improved tracking is underway

  3. Quantitative digital radiography with two dimensional flat panels

    International Nuclear Information System (INIS)

    Dinten, J.M.; Robert-Coutant, C.; Darboux, M.

    2003-01-01

    Purpose: Attenuation law relates radiographic images to irradiated object thickness and chemical composition. Film radiography exploits qualitatively this property for diagnosis. Digital radiographic flat panels present large dynamic range, reproducibility and linearity properties which open the gate for quantification. We will present, through two applications (mammography and bone densitometry), an approach to extract quantitative information from digital 2D radiographs. Material and method: The main difficulty for quantification is X-rays scatter, which superimposes to acquisition data. Because of multiple scatterings and 3D geometry dependence, it cannot be directly exploited through an exact analytical model. Therefore we have developed an approach for its estimation and subtraction from medical radiographs, based on approximations and derivations of analytical models of scatter formation in human tissues. Results: In digital mammography, the objective is to build a map of the glandular tissue thickness. Its separation from fat tissue is based on two equations: height of compression and attenuation. This last equation needs X-Rays scatter correction. In bone densitometry, physicians look for quantitative bone mineral density. Today, clinical DEXA systems use collimated single or linear detectors to eliminate scatter. This scanning technology induces poor image quality. By applying our scatter correction approach, we have developed a bone densitometer using a digital flat panel (Lexxos, DMS). It provides with accurate and reproducible measurements while presenting radiological image quality. Conclusion: These applications show how information processing, and especially X-Rays scatter processing, enables to extract quantitative information from digital radiographs. This approach, associated to Computer Aided Diagnosis algorithms or reconstructions algorithms, gives access to useful information for diagnosis. (author)

  4. Constancy tests radiography X-ray devices with CR system

    International Nuclear Information System (INIS)

    Durdikova, M.; Zakova, M.

    2005-01-01

    The paper presents the changes in QAP (Quality Assurance Program) as consequence of digitalisation of medical facilities. Digitalisation brings many advantages - more comfort for personal use, images are easy achievable and transferable to workstation, fine quality images by postprocessing are easily achievable. But it must be taken into account that due to simplicity of image make it is sometimes taken more images then necessary .There are two possible ways of digitalisation in radiography: to exchange conventional developer machine by Computer Radiography (CR), that means to use CR reader and cassette with phosphor plate - un-direct digitalisation or to use special radiography X-ray devices with flat-panel detector -direct radiography. (authors)

  5. Experiments on muon radiography with emulsion track detectors

    International Nuclear Information System (INIS)

    Aleksandrov, Andrey; Bagulya, Alexander; Baklagin, Sergei; Chernyavsky, Mikhail; Galkin, Vladimir; Grachev, Victor; Konovalova, Nina; Managadze, Alexander; Polukhina, Natalya; Roganova, Tatiana; Starkov, Nikolai; Shchedrina, Tatiana; Tioukov, Valeri; Vladymirov, Mykhailo; Zemskova, Svetlana

    2016-01-01

    Muon radiography is a method of study the internal structure of large natural and industrial objects based on sensing an object with a flux of cosmic muons with their subsequent registration and analysis of the pattern of their dispersion, or conplete (or partial) absorption. The Lebedev Physical Institute of the Russian Academy of Sciences and the Skobeltsyn Institute of Nuclear Physics of Moscow State University have started a series of muon radiography experiments with nuclear emulsion detectors. As a result, the optimal conditions for experiment arrangement have been determined, algorithms of data processing have been worked out, and peculiarities of the method have been ultimately investigated

  6. The scope of detector Medipix2 in micro-radiography of biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@utef.cvut.cz [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic); Weyda, F. [Biology Centre of the Academy of Sciences of the Czech Republic, Institute of Entomology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic); Faculty of Science, University of South Bohemia, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic); Jakubek, J. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic); Skrabal, P. [Faculty of Biomedical Engineering, Czech Technical University in Prague, Nam. Sitna 3105, CZ-272 01 Kladno (Czech Republic); Sopko, V.; Vavrik, D. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic)

    2011-05-15

    We present our experimental setup devoted to high resolution X-ray micro-radiography that is suitable for imaging of small biological samples. The photon source is a FeinFocus micro-focus X-ray tube. The single photon counting pixel device Medipix2 serves as imaging area. Recently used imaging detectors as radiography films or scintillator detectors, cannot visualize required information about inner structure of scanned sample. Detectors Medipix2 do not suffer from so-called dark current noise and work in unlimited dynamic range. These features of detectors confer high quality and high contrast of final images. The radiographic imaging with detectors Medipix2 represents non-invasive and non-destructive method of investigation. Hereby, we demonstrate results of micro-radiographic study of internal structures of tiny biological samples. In addition to morphological and anatomical studies, we would like to present preliminary study of dynamic processes inside of organisms using micro-radiographic video-capturing.

  7. The scope of detector Medipix2 in micro-radiography of biological samples

    International Nuclear Information System (INIS)

    Dammer, J.; Weyda, F.; Jakubek, J.; Skrabal, P.; Sopko, V.; Vavrik, D.

    2011-01-01

    We present our experimental setup devoted to high resolution X-ray micro-radiography that is suitable for imaging of small biological samples. The photon source is a FeinFocus micro-focus X-ray tube. The single photon counting pixel device Medipix2 serves as imaging area. Recently used imaging detectors as radiography films or scintillator detectors, cannot visualize required information about inner structure of scanned sample. Detectors Medipix2 do not suffer from so-called dark current noise and work in unlimited dynamic range. These features of detectors confer high quality and high contrast of final images. The radiographic imaging with detectors Medipix2 represents non-invasive and non-destructive method of investigation. Hereby, we demonstrate results of micro-radiographic study of internal structures of tiny biological samples. In addition to morphological and anatomical studies, we would like to present preliminary study of dynamic processes inside of organisms using micro-radiographic video-capturing.

  8. Dual energy radiography using active detector technology

    International Nuclear Information System (INIS)

    Seibert, J.A.; Poage, T.F.; Alvarez, R.E.

    1996-01-01

    A new technology has been implemented using an open-quotes active-detectorclose quotes comprised of two computed radiography (CR) imaging plates in a sandwich geometry for dual-energy radiography. This detector allows excellent energy separation, short exposure time, and high signal to noise ratio (SNR) for clinically robust open-quotes bone-onlyclose quotes and open-quotes soft-tissue onlyclose quotes images with minimum patient motion. Energy separation is achieved by two separate exposures at widely different kVp's: the high energy (120 kVp + 1.5 mm Cu filter) exposure is initiated first, followed by a short burst of intense light to erase the latent image on the front plate, and then a 50 kVp (low energy) exposure. A personal computer interfaced to the x-ray generator, filter wheel, and active detector system orchestrates the acquisition sequence within a time period of 150 msec. The front and back plates are processed using a CR readout algorithm with fixed speed and wide dynamic range. open-quotes Bone-onlyclose quotes and open-quotes soft-tissue onlyclose quotes images are calculated by geometric alignment of the two images and application of dual energy decomposition algorithms on a pixel by pixel basis. Resultant images of a calibration phantom demonstrate an increase of SNR 2 / dose by ∼73 times when compared to a single exposure open-quotes passive-detectorclose quotes comprised of CR imaging plates, and an ∼8 fold increase compared to a screen-film dual-energy cassette comprised of different phosphor compounds. In conclusion, dual energy imaging with open-quotes active detectorclose quotes technology is clinically feasible and can provide substantial improvements over conventional methods for dual-energy radiography

  9. Contrast-detail analysis of three flat panel detectors for digital radiography

    International Nuclear Information System (INIS)

    Borasi, Giovanni; Samei, Ehsan; Bertolini, Marco; Nitrosi, Andrea; Tassoni, Davide

    2006-01-01

    In this paper we performed a contrast detail analysis of three commercially available flat panel detectors, two based on the indirect detection mechanism (GE Revolution XQ/i, system A, and Trixell/Philips Pixium 4600, system B) and one based on the direct detection mechanism (Hologic DirectRay DR 1000, system C). The experiment was conducted using standard x-ray radiation quality and a widely used contrast-detail phantom. Images were evaluated using a four alternative forced choice paradigm on a diagnostic-quality softcopy monitor. At the low and intermediate exposures, systems A and B gave equivalent performances. At the high dose levels, system A performed better than system B in the entire range of target sizes, even though the pixel size of system A was about 40% larger than that of system B. At all the dose levels, the performances of the system C (direct system) were lower than those of system A and B (indirect systems). Theoretical analyses based on the Perception Statistical Model gave similar predicted SNR T values corresponding to an observer efficiency of about 0.08 for systems A and B and 0.05 for system C

  10. Large area x-ray detectors for cargo radiography

    Science.gov (United States)

    Bueno, C.; Albagli, D.; Bendahan, J.; Castleberry, D.; Gordon, C.; Hopkins, F.; Ross, W.

    2007-04-01

    Large area x-ray detectors based on phosphors coupled to flat panel amorphous silicon diode technology offer significant advances for cargo radiologic imaging. Flat panel area detectors provide large object coverage offering high throughput inspections to meet the high flow rate of container commerce. These detectors provide excellent spatial resolution when needed, and enhanced SNR through low noise electronics. If the resolution is reduced through pixel binning, further advances in SNR are achievable. Extended exposure imaging and frame averaging enables improved x-ray penetration of ultra-thick objects, or "select-your-own" contrast sensitivity at a rate many times faster than LDAs. The areal coverage of flat panel technology provides inherent volumetric imaging with the appropriate scanning methods. Flat panel area detectors have flexible designs in terms of electronic control, scintillator selection, pixel pitch, and frame rates. Their cost is becoming more competitive as production ramps up for the healthcare, nondestructive testing (NDT), and homeland protection industries. Typically used medical and industrial polycrystalline phosphor materials such as Gd2O2S:Tb (GOS) can be applied to megavolt applications if the phosphor layer is sufficiently thick to enhance x-ray absorption, and if a metal radiator is used to augment the quantum detection efficiency and reduce x-ray scatter. Phosphor layers ranging from 0.2-mm to 1-mm can be "sandwiched" between amorphous silicon flat panel diode arrays and metal radiators. Metal plates consisting of W, Pb or Cu, with thicknesses ranging from 0.25-mm to well over 1-mm can be used by covering the entire area of the phosphor plate. In some combinations of high density metal and phosphor layers, the metal plate provides an intensification of 25% in signal due to electron emission from the plate and subsequent excitation within the phosphor material. This further improves the SNR of the system.

  11. Technical characterization of five x-ray detectors for paediatric radiography applications

    Science.gov (United States)

    Marshall, N. W.; Smet, M.; Hofmans, M.; Pauwels, H.; De Clercq, T.; Bosmans, H.

    2017-12-01

    Physical image quality of five x-ray detectors used in the paediatric imaging department is characterized with the aim of establishing the range/scope of imaging performance provided by these detectors for neonatal imaging. Two computed radiography (CR) detectors (MD4.0 powder imaging plate (PIP) and HD5.0 needle imaging plate (NIP), Agfa HealthCare NV, B-2640 Mortsel, Belgium) and three flat panel detectors (FPD) (the Agfa DX-D35C and DX-D45C and the DRX-2530C (Carestream Health Inc., Rochester, NY 14608, USA)) were assessed. Physical image quality was characterized using the detector metrics given by the International Electrotechnical Commission (IEC 62220-1) to measure modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) using the IEC-specified beam qualities of RQA3 and RQA5. The DQE was evaluated at the normal operating detector air kerma (DAK) level, defined at 2.5 µGy for all detectors, and at factors of 1/3.2 and 3.2 times the normal level. MTF curves for the different detectors were similar at both RQA3 and RQA5 energies; the average spatial frequency for the 50% point (MTF0.5) at RQA3 was 1.26 mm-1, with a range from 1.20 mm-1 to 1.37 mm-1. The DQE of the NIP CR compared to the PIP CR was notably greater and similar to that for the FPD devices. At RQA3, average DQE for the FPD and NIP (at 0.5 mm-1 2.5 µGy) was 0.57 compared to 0.26 for the PIP CR. At the RQA5 energy, the DRX-2530C and the DX-D45C had the highest DQE (~0.6 at 0.5 mm-1 2.5 µGy). Noise separation analysis using the polynomial model showed higher electronic noise for the DX-D35C and DRX-2530C detectors; this explains the reduced DQE seen at 0.7 µGy/image. The NIP CR detector offers notably improved DQE performance compared to the PIP CR system and a value similar to the DQE for FPD devices at the RQA3 energy.

  12. Evaluation of digital detector arrays systems for industrial radiography

    International Nuclear Information System (INIS)

    Silva, Aline S.S.; Oliveira, Davi F.; Gomes, Célio S.; Azeredo, Soraia R.; Lopes, Ricardo T.

    2017-01-01

    Digital Detector Arrays (DDA) or Flat Panel Detector (FPD) is a highly efficient technique that is used in nondestructive testing of internal features of an object. The evaluation of DDA systems for industrial radiography is important to ensure the image quality and to enables long-term stability of this system. This evaluation is specified by ASTM E2737 - 10, which describes the fundamental parameters of DDA systems to be measured. The tests require the usage of either the five-groove wedge or the duplex plate phantom with separate Image Quality Indicators (IQIs). The purpose of this work was evaluate the radiographic performance achieved using both techniques in two DDA systems manufactured by GEIT: DXR250P and DXR250V, which have thallium-doped cesium iodide (CsI:Tl) and terbium-doped gadolinium oxysulfide (Gd 2 O 2 S:Tb - GOS) scintillators, respectively. For this purpose, it was used an X-ray equipment as radiation source. The image quality parameters analyzed were Image Lag (IL), Offset Level (OL), Bad Pixel distribution, Burn In (BI), Spatial Resolution (SR), Material Thickness Range (MTR), Contrast Sensitivity (CS), Signal Level (SL) and Signal-to-Noise Ratio (SNR). As result of this study, has been observed that the use of the five-groove wedge phantom made the measurements to become easier to execute. Regarding the DDA system, the DXR250P presented more IL and BI, but produced images with better CS and SNR and needed a dose almost twice smaller than the DXR250V to achieve a similar SL. (author)

  13. Evaluation of digital detector arrays systems for industrial radiography

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Aline S.S.; Oliveira, Davi F.; Gomes, Célio S.; Azeredo, Soraia R.; Lopes, Ricardo T., E-mail: aline@lin.ufrj.br, E-mail: davi@lin.ufrj.br.br, E-mail: celio@lin.ufrj.br, E-mail: soraia@lin.ufrj.br, E-mail: ricardo@lin.ufrj.br, E-mail: davi.oliveira@uerj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentação Nuclear

    2017-07-01

    Digital Detector Arrays (DDA) or Flat Panel Detector (FPD) is a highly efficient technique that is used in nondestructive testing of internal features of an object. The evaluation of DDA systems for industrial radiography is important to ensure the image quality and to enables long-term stability of this system. This evaluation is specified by ASTM E2737 - 10, which describes the fundamental parameters of DDA systems to be measured. The tests require the usage of either the five-groove wedge or the duplex plate phantom with separate Image Quality Indicators (IQIs). The purpose of this work was evaluate the radiographic performance achieved using both techniques in two DDA systems manufactured by GEIT: DXR250P and DXR250V, which have thallium-doped cesium iodide (CsI:Tl) and terbium-doped gadolinium oxysulfide (Gd{sub 2}O{sub 2}S:Tb - GOS) scintillators, respectively. For this purpose, it was used an X-ray equipment as radiation source. The image quality parameters analyzed were Image Lag (IL), Offset Level (OL), Bad Pixel distribution, Burn In (BI), Spatial Resolution (SR), Material Thickness Range (MTR), Contrast Sensitivity (CS), Signal Level (SL) and Signal-to-Noise Ratio (SNR). As result of this study, has been observed that the use of the five-groove wedge phantom made the measurements to become easier to execute. Regarding the DDA system, the DXR250P presented more IL and BI, but produced images with better CS and SNR and needed a dose almost twice smaller than the DXR250V to achieve a similar SL. (author)

  14. Planarity certification of ATLAS Micromegas detector panels

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Ralph; Biebel, Otmar; Bortfeldt, Jonathan; Flierl, Bernhard; Hertenberger, Ralf; Loesel, Philipp; Herrmann, Maximilian [LMU Muenchen (Germany); Zibell, Andre [JMU Wuerzburg (Germany)

    2016-07-01

    During the second long LHC shutdown, 2019/20, the precision tracking detectors of the ATLAS muon spectrometer in the inner end caps will be replaced using Micromegas, a planar gas-detector technology. Modules of 2 m{sup 2} area are built in quadruplets from five precisely planar sandwich panels that define the anodes and the cathodes of the four active detector planes. A panel is composed of three consecutive layers FR4 - aluminum honeycomb - FR4. Single plane spatial particle resolution below 100 μm is achievable when the deviations from planarity of the strip-anodes do not exceed 80 μm RMS over the whole active area and the parallelism of the readout strips is within 30 μm. In order to measure the dimensional accuracy of each panel, laser distance sensors combined with a coordinate measurement system have been investigated. The sensor requirements to measure the planarity of the panels are a resolution of 0.3 μm and a beam spot diameter of ∼20 μm, well below 100 μ m the size of the smallest structures. We report on achieved planarities of the panels and the performance of the laser sensor system. A panel with an RMS better than 30 μm was build and the evolution of its planarity due to humidity and temperature effects is shown.

  15. Photon-counting digital radiography using high-pressure xenon filled detectors

    CERN Document Server

    Li, Maozhen; Johns, P C

    2001-01-01

    Digital radiography overcomes many of the limitations of the traditional screen/film system. Further enhancements in the digital radiography image are possible if the X-ray image receptor could measure the energy of individual photons instead of simply integrating their energy, as is the case at present. A prototype photon counting scanned projection radiography system has been constructed, which combines a Gas Electron Multiplier (GEM) and a Gas Microstrip Detector (GMD) using Xe : CH sub 4 (90 : 10) at high pressure. With the gain contribution from the GEM, the GMD can be operated at lower and safer voltages making the imaging system more reliable. Good energy resolution, and spatial resolution comparable to that of screen/film, have been demonstrated for the GEM/GMD hybrid imaging system in photon counting mode for X-ray spectra up to 50 kV.

  16. The digital flat-panel X-Ray detectors

    International Nuclear Information System (INIS)

    Risticj, S. Goran

    2013-01-01

    In a digital imaging system, the incident x-ray image must be sampled both in the spatial and intensity dimensions. In the spatial dimensions, samples are obtained as averages of the intensity over picture elements or pixels. In the intensity dimension, the signal is digitalized into one of a finite number of levels or bits. Two main types of digital flat-panel detectors are based on the direct conversion, which contains the photoconductor, and on indirect conversion, which contains phosphor. The basics of these detectors are given. Coupling traditional x-ray detection material such as photoconductors and phosphors with a large-area active-matrix readout structure forms the basis of flat panel x-ray images. Active matrix technology provides a new, highly efficient, real time method for electronically storing and measuring the product of the x-ray interaction stage whether the product is visible wavelength photons or electrical charges. The direct and indirect detectors, made as the active-matrix flat-panel detectors containing sensing/storage elements, switching elements (diodes or thin film transistors (TFTS)) and image processing module, are described. Strengths and limitations of stimulable phosphors are discussed. The main advantages and disadvantages of mentioned x-ray detectors are also analyzed. (Author)

  17. High resolution X radiography imaging detector-micro gap chamber

    International Nuclear Information System (INIS)

    Long Huqiang; Wang Yun; Xu Dong; Xie Kuanzhong; Bian Jianjiang

    2007-01-01

    Micro gap chamber (MGC) is a new type of Two-Dimensional position sensitive detector having excellent properties on the space and time resolution, counting rate, 2D compact structure and the flexible of application. It will become a candidate of a new tracking detector for high energy physics experiment. The basic structure and properties of MGC as well as its main research subjects are presented in this paper. Furthermore, the feasibility and validity of utilizing diamond films as the MGC gap material were also discussed in detail. So, a potential radiography imaging detector is provided in order to realize X image and X ray diffraction experiment having very good spatial and time resolution in the 3rd Generation of Synchrotron Radiation Facility. (authors)

  18. A new CCD-camera neutron radiography detector at the Atominstitute of the Austrian Universities

    International Nuclear Information System (INIS)

    Koerner, S.; Boeck, H.; Rauch, H.; Lehmann, E.

    1999-01-01

    Neutron radiography provides a very efficient tool for non-destructive testing as well as for many applications in fundamental research. A neutron beam penetrating a specimen is attenuated by the sample material and detected by a two dimensional imaging device. The image contains information about materials and structure inside the sample because neutrons are attenuated according to the basic law of radiation attenuation. At the Atominstitute of the Austrian Universities neutron radiographic examinations have been carried out for more than 35 years, mainly with detectors consisting of X-ray films and a Gd- converter enclosed in a vacuum cassette. Presently a neutron tomography set-up is under development. For high quality 3D image reconstruction, about 200 digitized neutron transmission images from different angles of the object are necessary. Therefore the first step was the design of an adequate electronic neutron radiography imaging device. The requirements for a detector suitable for neutron tomography are: exact and reproducible positioning, easy handling, high spatial resolution and dynamic range, high efficiency and a good linearity. The key components of the detector system selected on the basis of the requirements consist of a neutron sensitive scintillator screen, a cooled slow scan CCD camera and a mirror to reflect the light emitted by the scintillator to the CCD camera. The whole assembly is placed in a light tight enclosure. In this paper the strategy of the selection of the individual detector components is described. Comparisons on the influence of the use of different components on the properties of the whole position sensitive imaging device are demonstrated. Finally the new CCD camera neutron radiography detector of the Atominstitute is presented and first results of test measurements performed at the neutron radiography facility NEUTRA at the continuous spallation source SINQ at Paul Scherrer Institute are shown.(author)

  19. FINAL SCIENTIFIC REPORT - PROTON RADIOGRAPHY: CROSS SECTION MEASUREMENTS AND DETECTOR DEVELOPMENT

    International Nuclear Information System (INIS)

    Longo, Michael J.; Gustafson, H. Richard.; Rajaram, Durga; Nigmanov, Turgun

    2007-01-01

    Proton radiography offers significant advantages over conventional X-ray radiography, including the capability of looking into thick, dense materials, better contrast for a wide range of materials, sensitivity to different materials of similar density, and better resolution because of the ability to focus beams. In order to achieve this capability it is crucial to understand the background due to neutrons and photons and to develop techniques to reduce it to tolerable levels. The physics goal of this project is to measure forward production of neutrons and photons produced by high-energy proton beams striking a variety of targets. This work is being carried out in conjunction with the Fermilab Experiment 907 (MIPP) collaboration including physicists from Lawrence Livermore Laboratory. Our group is responsible for the E907 forward neutron/photon calorimeters. These are the only detectors in the experiment that provide information on neutrons and photons. We are taking a leading role in obtaining and analyzing the for-ward production data and in developing an optimal detector for proton radiography. With the support of our Stewardship Science Academic Alliances grant, we were able to design, build, and commission the calorimeters on budget and ahead of schedule. E-907 officially started physics running at Fermilab in January 2005, and data taking continued through February 2006. Data were taken on a range of targets, from liquid hydrogen to uranium, at beam energies from 5 GeV/c to 120 GeV/c. The analysis of the data is challenging because data from many different detector systems must be understood and merged and over 31 million events were accumulated. Our recent efforts have been devoted to the calibration of the neutron and photon detectors, to track and shower reconstruction, identification of forward-going neutrons, and simulation of the calorimeters in a Monte Carlo. Reconstruction of the data with improved tracking is underway

  20. Noise power spectrum of the fixed pattern noise in digital radiography detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Sik, E-mail: dskim@hufs.ac.kr [Department of Electronics Engineering, Hankuk University of Foreign Studies, Gyeonggi-do 449-791 (Korea, Republic of); Kim, Eun [R& D Center, DRTECH Co., Gyeonggi-do 13558 (Korea, Republic of)

    2016-06-15

    Purpose: The fixed pattern noise in radiography image detectors is caused by various sources. Multiple readout circuits with gate drivers and charge amplifiers are used to efficiently acquire the pixel voltage signals. However, the multiple circuits are not identical and thus yield nonuniform system gains. Nonuniform sensitivities are also produced from local variations in the charge collection elements. Furthermore, in phosphor-based detectors, the optical scattering at the top surface of the columnar CsI growth, the grain boundaries, and the disorder structure causes spatial sensitivity variations. These nonuniform gains or sensitivities cause fixed pattern noise and degrade the detector performance, even though the noise problem can be partially alleviated by using gain correction techniques. Hence, in order to develop good detectors, comparative analysis of the energy spectrum of the fixed pattern noise is important. Methods: In order to observe the energy spectrum of the fixed pattern noise, a normalized noise power spectrum (NNPS) of the fixed pattern noise is considered in this paper. Since the fixed pattern noise is mainly caused by the nonuniform gains, we call the spectrum the gain NNPS. We first asymptotically observe the gain NNPS and then formulate two relationships to calculate the gain NNPS based on a nonuniform-gain model. Since the gain NNPS values are quite low compared to the usual NNPS, measuring such a low NNPS value is difficult. By using the average of the uniform exposure images, a robust measuring method for the gain NNPS is proposed in this paper. Results: By using the proposed measuring method, the gain NNPS curves of several prototypes of general radiography and mammography detectors were measured to analyze their fixed pattern noise properties. We notice that a direct detector, which is based on the a-Se photoconductor, showed lower gain NNPS than the indirect-detector case, which is based on the CsI scintillator. By comparing the gain

  1. Development of a novel direct X-ray detector using photoinduced discharge (PID) readout for digital radiography

    Science.gov (United States)

    Heo, D.; Jeon, S.; Kim, J.-S.; Kim, R. K.; Cha, B. K.; Moon, B. J.; Yoon, J.

    2013-02-01

    We developed a novel direct X-ray detector using photoinduced discharge (PID) readout for digital radiography. The pixel resolution is 512 × 512 with 200 μm pixel and the overall active dimensions of the X-ray imaging panel is 10.24 cm × 10.24 cm. The detector consists of an X-ray absorption layer of amorphous selenium, a charge accumulation layer of metal, and a PID readout layer of amorphous silicon. In particular, the charge accumulation is pixelated because image charges generated by X-ray should be stored pixel by pixel. Here the image charges, or holes, are recombined with electrons generated by the PID method. We used a 405 nm laser diode and cylindrical lens to make a line beam source with a width of 50 μm for PID readout, which generates charges for each pixel lines during the scan. We obtained spatial frequencies of about 1.0 lp/mm for the X-direction (lateral direction) and 0.9 lp/mm for the Y-direction (scanning direction) at 50% modulation transfer function.

  2. Detection of on-surface objects with an underground radiography detector system using cosmic-ray muons

    Science.gov (United States)

    Fujii, Hirofumi; Hara, Kazuhiko; Hayashi, Kohei; Kakuno, Hidekazu; Kodama, Hideyo; Nagamine, Kanetada; Sato, Kazuyuki; Sato, Kotaro; Kim, Shin-Hong; Suzuki, Atsuto; Takahashi, Kazuki; Takasaki, Fumihiko

    2017-05-01

    We have developed a compact muon radiography detector to investigate the status of the nuclear debris in the Fukushima Daiichi Reactors. Our previous observation showed that a large portion of the Unit-1 Reactor fuel had fallen to floor level. The detector must be located underground to further investigate the status of the fallen debris. To investigate the performance of muon radiography in such a situation, we observed 2 m cubic iron blocks located on the surface of the ground through different lengths of ground soil. The iron blocks were imaged and their corresponding iron density was derived successfully.

  3. New detectors technology for radiology imaging

    International Nuclear Information System (INIS)

    Cuzin, M.; Peyret, O.

    1998-01-01

    We summarize the main parameters which describes the radiological image at first and the advantages of pixel detectors. All detectors converts X-rays in charges either with an intermediate step with light or directly in a semi-conductor media. That is true for tomography which is the first domain where digital processing have been taken in account and for radiology where flat panel are now proposed to radiologists. Nevertheless, luminescent stimulated screens are a good way to prepare users with digital radiography. As such technique is not valuable for dynamic acquisition, we describe systems which used standard luminescent screens with CCD cameras or with IIR. Some description and comparison of flat panel independent pixel detectors are given. (authors)

  4. Investigation of physical imaging properties in various digital radiography systems

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hoi Woun [Dept. of Radiological Science, Baekseok Culture University, Cheonan (Korea, Republic of); Min, Jung Hwan [Dept. of Radiological technology, Shingu University, Seongnam (Korea, Republic of); Yoon, Yong Su [Dept. of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Kyushu (Japan); Kim, Jung Min [Dept. of Health and Environmental Science, College of Health Science, Korea University, Seoul (Korea, Republic of)

    2017-09-15

    We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

  5. Quality comparison of direct digital panoramic radiography and computed radiography panoramic

    Directory of Open Access Journals (Sweden)

    Dariush Goodarzipour

    2013-09-01

    Full Text Available BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels. The first category is defined as computed radiography (CR or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR. Both of these technologies have their own advantages and disadvantages. One of the most important fields in comparison of these systems is their resultant image quality. The purpose of this study was to compare the subjective image quality of DDR and CR digital panoramic system, and to assess the overall density and contrast of their images. METHODS: 200 patients were randomly allocated to two digital systems: Promax [central control digital (CCD] and XC [photostimulable phosphor plates (PSP]. Image quality was evaluated in six regions on a 3-point scale by three oral and maxillofacial radiologists independently. In addition, observers assessed overall density and contrast of each image on a 3-point scale. RESULTS: Using chi-square test, no statistically significant differences were found (P >0.05 in subjective image quality of anatomic structures between the two radiographic systems. But DDR system outperformed CR system in overall density and contrast of the image. P values for both overall density and contrast of the images was less than 0.001. CONCLUSIONS: The subjective image quality of CR and DDR panoramic systems in specified anatomic regions were found statistically comparable in this study. In overall density and contrast of the radiographs, DDR system proved better than CR system.

  6. Indirect flat-panel detector with avalanche gain: Fundamental feasibility investigation for SHARP-AMFPI (scintillator HARP active matrix flat panel imager)

    International Nuclear Information System (INIS)

    Zhao Wei; Li Dan; Reznik, Alla; Lui, B.J.M.; Hunt, D.C.; Rowlands, J.A.; Ohkawa, Yuji; Tanioka, Kenkichi

    2005-01-01

    An indirect flat-panel imager (FPI) with avalanche gain is being investigated for low-dose x-ray imaging. It is made by optically coupling a structured x-ray scintillator CsI(Tl) to an amorphous selenium (a-Se) avalanche photoconductor called HARP (high-gain avalanche rushing photoconductor). The final electronic image is read out using an active matrix array of thin film transistors (TFT). We call the proposed detector SHARP-AMFPI (scintillator HARP active matrix flat panel imager). The advantage of the SHARP-AMFPI is its programmable gain, which can be turned on during low dose fluoroscopy to overcome electronic noise, and turned off during high dose radiography to avoid pixel saturation. The purpose of this paper is to investigate the important design considerations for SHARP-AMFPI such as avalanche gain, which depends on both the thickness d Se and the applied electric field E Se of the HARP layer. To determine the optimal design parameter and operational conditions for HARP, we measured the E Se dependence of both avalanche gain and optical quantum efficiency of an 8 μm HARP layer. The results were used in a physical model of HARP as well as a linear cascaded model of the FPI to determine the following x-ray imaging properties in both the avalanche and nonavalanche modes as a function of E Se : (1) total gain (which is the product of avalanche gain and optical quantum efficiency); (2) linearity; (3) dynamic range; (4) gain nonuniformity resulting from thickness nonuniformity; and (5) effects of direct x-ray interaction in HARP. Our results showed that a HARP layer thickness of 8 μm can provide adequate avalanche gain and sufficient dynamic range for x-ray imaging applications to permit quantum limited operation over the range of exposures needed for radiography and fluoroscopy

  7. Application of imaging plate neutron detector to neutron radiography

    CERN Document Server

    Fujine, S; Kamata, M; Etoh, M

    1999-01-01

    As an imaging plate neutron detector (IP-ND) has been available for thermal neutron radiography (TNR) which has high resolution, high sensitivity and wide range, some basic characteristics of the IP-ND system were measured at the E-2 facility of the KUR. After basic performances of the IP were studied, images with high quality were obtained at a neutron fluence of 2 to 7x10 sup 8 n cm sup - sup 2. It was found that the IP-ND system with Gd sub 2 O sub 3 as a neutron converter material has a higher sensitivity to gamma-ray than that of a conventional film method. As a successful example, clear radiographs of the flat view for the fuel side plates with boron burnable poison were obtained. An application of the IP-ND system to neutron radiography (NR) is presented in this paper.

  8. Tests of a new CCD-camera based neutron radiography detector system at the reactor stations in Munich and Vienna

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, E; Pleinert, H [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Schillinger, B [Technische Univ. Muenchen (Germany); Koerner, S [Atominstitut der Oesterreichischen Universitaeten, Vienna (Austria)

    1997-09-01

    The performance of the new neutron radiography detector designed at PSI with a cooled high sensitive CCD-camera was investigated under real neutronic conditions at three beam ports of two reactor stations. Different converter screens were applied for which the sensitivity and the modulation transfer function (MTF) could be obtained. The results are very encouraging concerning the utilization of this detector system as standard tool at the radiography stations at the spallation source SINQ. (author) 3 figs., 5 refs.

  9. Neutron radiography of thick hydrogenous materials with use of an imaging plate neutron detector

    International Nuclear Information System (INIS)

    Kato, K.; Matsumoto, G.; Karasawa, Y.; Niimura, N.; Matsubayashi, M.; Tsuruno, A.

    1996-01-01

    The value of the neutron mass attenuation coefficient of hydrogen being very high, it is extremely difficult to image normal size, living animals with neutron radiography. However, the authors suggest the possibility of applying neutron radiography for biomedical specimens. The organs in the breast, bones and cartilages in the extremities, and the tail of mice and rats were clearly imaged by neutron radiography with Gd foils as neutron converters and X-ray films. However, no contours of the organs in the mouse abdomen were visible with neutron radiography with an exposure time of 200 s. By adding Gd or Li compounds as neutron converters to imaging X-ray plates, imaging plates have been developed for neutron detectors. A trial using these imaging plates for neutron radiography of water-filled containers and the abdomen of mice was completed. The roundness of a 100 ml-beaker was imaged with a neutron exposure of 180 s. Obscure contours of the liver and kidneys of the mouse were imaged with a neutron exposure of 100 s. (orig.)

  10. The scope of detector Medipix2 in micro-radiography of biological samples

    Czech Academy of Sciences Publication Activity Database

    Dammer, J.; Weyda, František; Jakůbek, J.; Škrabal, P.; Sopko, V.; Vavřík, D.

    2011-01-01

    Roč. 633, č. 1 (2011), s. 175-176 ISSN 0168-9002. [International Workshop on Radiation Imaging Detectors /11./. Praha, 29.06.2009-03.07.2009] R&D Projects: GA MŠk 2B06005 Grant - others:Ministerstvo školství(CZ) 6840770040; GA MŠk(CZ) 1P04LA211; GA MŠk(CZ) LC06041 Program:1P; LC Institutional research plan: CEZ:AV0Z50070508 Keywords : x-ray imaging * digital radiography * photon and x-ray detectors Subject RIV: EA - Cell Biology Impact factor: 1.207, year: 2011

  11. Development of ''SonialvisionSafireII'' system with a new digital radiography device

    International Nuclear Information System (INIS)

    Sano, Takayuki; Okumura, Takeshi; Sakai, Takihito; Fujiwara, Masashi; Toyoda, Toshihide

    2007-01-01

    We released the world's first X-TV system equipped with a 17 inch direct conversion type flat panel X-ray detector (FPD) ''Safire'' in an radiofrequency (RF) table in 2004. Our latest X-TV system, called SonialvisionSafireII, incorporates the digital radiography device and the high voltage generator both of which were newly developed to take better advantage of the characteristics of the FPD. The following are the features of the latest system: Image acquisition and processing with the original matrix of FPD (up to 2880 x 2880 matrix with a 17-inch field of view (FOV)), High-speed radiography in serial acquisition mode (up to 15 fps) and tomosynthesis acquisition mode (up to 30 fps), Operationally improved digital radiography device using a general-purpose personal computer. (author)

  12. Gain and offset calibration reduces variation in exposure-dependent SNR among systems with identical digital flat-panel detectors.

    Science.gov (United States)

    Willis, Charles E; Vinogradskiy, Yevgeniy Y; Lofton, Brad K; White, R Allen

    2011-07-01

    The conditions under which vendor performance criteria for digital radiography systems are obtained do not adequately simulate the conditions of actual clinical imaging with respect to radiographic technique factors, scatter production, and scatter control. Therefore, the relationship between performance under ideal conditions and performance in clinical practice remains unclear. Using data from a large complement of systems in clinical use, the authors sought to develop a method to establish expected performance criteria for digital flat-panel radiography systems with respect to signal-to-noise ratio (SNR) versus detector exposure under clinical conditions for thoracic imaging. The authors made radiographic exposures of a patient-equivalent chest phantom at 125 kVp and 180 cm source-to-image distance. The mAs value was modified to produce exposures above and below the mAs delivered by automatic exposure control. Exposures measured free-in-air were corrected to the imaging plane by the inverse square law, by the attenuation factor of the phantom, and by the Bucky factor of the grid for the phantom, geometry, and kilovolt peak. SNR was evaluated as the ratio of the mean to the standard deviation (SD) of a region of interest automatically selected in the center of each unprocessed image. Data were acquired from 18 systems, 14 of which were tested both before and after gain and offset calibration. SNR as a function of detector exposure was interpolated using a double logarithmic function to stratify the data into groups of 0.2, 0.5, 1.0, 2.0, and 5.0 mR exposure (1.8, 4.5, 9.0, 18, and 45 microGy air KERMA) to the detector. The mean SNR at each exposure interval after calibration exhibited linear dependence on the mean SNR before calibration (r2=0.9999). The dependence was greater than unity (m = 1.101 +/- 0.006), and the difference from unity was statistically significant (p grid replacement. The nonconformant behavior of the other system was corrected by replacing

  13. Difference in diaphragmatic motion during tidal breathing in a standing position between COPD patients and normal subjects: Time-resolved quantitative evaluation using dynamic chest radiography with flat panel detector system (“dynamic X-ray phrenicography”)

    International Nuclear Information System (INIS)

    Yamada, Yoshitake; Ueyama, Masako; Abe, Takehiko; Araki, Tetsuro; Abe, Takayuki; Nishino, Mizuki; Jinzaki, Masahiro; Hatabu, Hiroto

    2017-01-01

    Highlights: • Dynamic X-ray phrenicography is a useful method for the evaluation of the diaphragms. • Its radiation dose is comparable to conventional two projection chest radiography. • Diaphragm motion during tidal breathing is larger in COPD than in normal subjects. • Higher BMI is also associated with increased excursions of the bilateral diaphragm. - Abstract: Objectives: To quantitatively compare diaphragmatic motion during tidal breathing in a standing position between chronic obstructive pulmonary disease (COPD) patients and normal subjects using dynamic chest radiography. Materials and methods: Thirty-nine COPD patients (35 males; age, 71.3 ± 8.4 years) and 47 normal subjects (non-smoker healthy volunteers) (20 males; age, 54.8 ± 9.8 years) underwent sequential chest radiographs during tidal breathing using dynamic chest radiography with a flat panel detector system. We evaluated the excursions and peak motion speeds of the diaphragms. The results were analyzed using an unpaired t-test and a multiple linear regression model. Results: The excursions of the diaphragms in COPD patients were significantly larger than those in normal subjects (right, 14.7 ± 5.5 mm vs. 10.2 ± 3.7 mm, respectively, P < 0.001; left, 17.2 ± 4.9 mm vs. 14.9 ± 4.2 mm, respectively, P = 0.022). Peak motion speeds in inspiratory phase were significantly faster in COPD patients compared to normal subjects (right, 16.3 ± 5.0 mm/s vs. 11.8 ± 4.2 mm/s, respectively, P < 0.001; left, 18.9 ± 4.9 mm/s vs. 16.7 ± 4.0 mm/s, respectively, P = 0.022). The multivariate analysis demonstrated that having COPD and higher body mass index were independently associated with increased excursions of the bilateral diaphragm (all P < 0.05), after adjusting for other clinical variables. Conclusions: Time-resolved quantitative evaluation of the diaphragm using dynamic chest radiography demonstrated that the diaphragmatic motion during tidal breathing in a standing position is larger and

  14. Difference in diaphragmatic motion during tidal breathing in a standing position between COPD patients and normal subjects: Time-resolved quantitative evaluation using dynamic chest radiography with flat panel detector system (“dynamic X-ray phrenicography”)

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Yoshitake, E-mail: yamada@rad.med.keio.ac.jp [Department of Radiology, Center for Pulmonary Functional Imaging, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis St., Boston, MA 02215 (United States); Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Ueyama, Masako, E-mail: ueyamam@fukujuji.org [Department of Health Care, Fukujuji Hospital, Japan Anti-Tuberculosis Association, 3-1-24 Matsuyama, Kiyose, Tokyo 204-8522 (Japan); Abe, Takehiko, E-mail: takehikoabe@hotmail.com [Department of Radiology, Fukujuji Hospital, Japan Anti-Tuberculosis Association, 3-1-24 Matsuyama, Kiyose, Tokyo 204-8522 (Japan); Araki, Tetsuro, E-mail: TARAKI@partners.org [Department of Radiology, Center for Pulmonary Functional Imaging, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis St., Boston, MA 02215 (United States); Abe, Takayuki, E-mail: abe.t@keio.jp [Department of Preventive Medicine and Public Health, Biostatistics Unit at Clinical and Translational Research Center, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Nishino, Mizuki, E-mail: Mizuki_Nishino11@dfci.harvard.edu [Department of Radiology, Center for Pulmonary Functional Imaging, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis St., Boston, MA 02215 (United States); Jinzaki, Masahiro, E-mail: jinzaki@rad.med.keio.ac.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Hatabu, Hiroto, E-mail: hhatabu@partners.org [Department of Radiology, Center for Pulmonary Functional Imaging, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis St., Boston, MA 02215 (United States); and others

    2017-02-15

    Highlights: • Dynamic X-ray phrenicography is a useful method for the evaluation of the diaphragms. • Its radiation dose is comparable to conventional two projection chest radiography. • Diaphragm motion during tidal breathing is larger in COPD than in normal subjects. • Higher BMI is also associated with increased excursions of the bilateral diaphragm. - Abstract: Objectives: To quantitatively compare diaphragmatic motion during tidal breathing in a standing position between chronic obstructive pulmonary disease (COPD) patients and normal subjects using dynamic chest radiography. Materials and methods: Thirty-nine COPD patients (35 males; age, 71.3 ± 8.4 years) and 47 normal subjects (non-smoker healthy volunteers) (20 males; age, 54.8 ± 9.8 years) underwent sequential chest radiographs during tidal breathing using dynamic chest radiography with a flat panel detector system. We evaluated the excursions and peak motion speeds of the diaphragms. The results were analyzed using an unpaired t-test and a multiple linear regression model. Results: The excursions of the diaphragms in COPD patients were significantly larger than those in normal subjects (right, 14.7 ± 5.5 mm vs. 10.2 ± 3.7 mm, respectively, P < 0.001; left, 17.2 ± 4.9 mm vs. 14.9 ± 4.2 mm, respectively, P = 0.022). Peak motion speeds in inspiratory phase were significantly faster in COPD patients compared to normal subjects (right, 16.3 ± 5.0 mm/s vs. 11.8 ± 4.2 mm/s, respectively, P < 0.001; left, 18.9 ± 4.9 mm/s vs. 16.7 ± 4.0 mm/s, respectively, P = 0.022). The multivariate analysis demonstrated that having COPD and higher body mass index were independently associated with increased excursions of the bilateral diaphragm (all P < 0.05), after adjusting for other clinical variables. Conclusions: Time-resolved quantitative evaluation of the diaphragm using dynamic chest radiography demonstrated that the diaphragmatic motion during tidal breathing in a standing position is larger and

  15. Reconstruction of Spectra Using X-ray Flat Panel Detector; Reconstruccion de Espectros de Rayos X Utilizando un Detector Flat Panel

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo, S.; Querol, A.; Pozuelo, F.; Juste, B.; Rodenas, J.; Verdu, G.

    2013-07-01

    In this work, we used a flat panel detector with a wedge of PMMA for absorbed dose curve for given working conditions of X-ray tube The relationship between absorbed dose curve recorded by the flat panel and primary X-ray spectrum is defined by a response function that can be obtained using the Monte Carlo method, namely the MCNP5 code. However there are some problems that affect the applicability of this method such as: flat panel characteristics and the characteristics of the physical process (ill-conditioned problem). Both aspects are discussed in this paper.

  16. Comparison of imaging properties of direct-type and indirect-type of flat-panel detector

    International Nuclear Information System (INIS)

    Matsumoto, Masao; Suekane, Koji; Ichimaru, Yasunobu; Ogata, Yuji; Inamura, Kiyonari; Kanai, Kouzou; Kanamori, Hitoshi

    2002-01-01

    A Flat-Panel Detector (FPD) has many advantages such as eliminating cassette handling and being able to display a preview image immediately in addition to the digital image processing and the networking. Thus, the FPD has ability to innovate the radiology department. We measured and evaluated the digital and over-all imaging properties (characteristic curves, modulation Transfer Functions, Wiener spectra and Noise Equivalent Quanta (NEQ) for the direct-type and indirect-type of FPD. The pre-sampling and overall NEQ of the indirect-type of FPD were better than the NEQ of the direct-type of FPD at lower spatial frequencies, but were worse at higher spatial frequencies. The FPD can take image data at real-time and be easy to digitalize. From these results, Screen/Film system and Computed Radiography system will be replaced by the FPD system, together with diffusion of CAD, cone beam Computed Tomography (CT) system and open-type Magnetic Resonance Imagining (MRI) system. (T. Tanaka)

  17. Digital radiography: description and user's guide

    International Nuclear Information System (INIS)

    Berthel, A.; Bonin, Th.; Cadilhon, S.; Thiery, Ch.; Chatellier, L.; Kaftandjian, V.; Honorat, Ph.; Torrent, J.; Le Brun, A.; Maglaive, J.C.; Moreau, Ph.; Pettier, J.L.; Rebuffel, V.; Roenelle, P.; Roussilhe, J.; Staat, St.; Tahon, M.

    2007-01-01

    The presented document arises from the work of the group 'Digital Radiography and sensors' of COFREND. It is a collective work of synthesis aimed to analyze the quality parameters of digital images influencing the answer and the diagnosis brought to a given industrial problem. Five families of digital sensors have been studied: 1. Image Intensifier coupled with CCD devices - 2. scintillators coupled with a CCD device- 3. Flat Panels with indirect conversion - 4. Flat Panels with direct electric conversion - 5. Photostimulable Storage Phosphor Screens). In particular, concerning a complete imaging chain, it deals with the notions of magnification, blur (unsharpness) (geometrical, kinetic or internal to the very sensor), noises, scattered radiation, spatial resolution, which is different from the one of analog detectors such as films, Contrast to Noise Ratio (CNR), sensitivity using IQIs, dynamic range, detection quantum efficiency, persistence and temporal resolution. This document is not a standard; it must be understood as a user's guide, and it approaches some essentials corrections to bring to a sensor in order to optimize his efficiency without losing information during the pre-processing phase in the radiographic acquisition. It also introduces some image processing tools commonly used. It can be used as a source document to the future elaboration of a standardisation document. It augurs not at all of the choice of a digital sensor with regard to the traditional radiographic film, but gives bases of reflection to a radio user for a sensible transfer from the classic radiography to the digital radiography. (authors)

  18. Photon counting detector for the personal radiography inspection system “SIBSCAN”

    Energy Technology Data Exchange (ETDEWEB)

    Babichev, E.A.; Baru, S.E. [Budker Institute of Nuclear Physics, Lavrentiev ave. 11, Novosibirsk 630090 (Russian Federation); Grigoriev, D.N. [Budker Institute of Nuclear Physics, Lavrentiev ave. 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State University, Pirogova st. 2, Novosibirsk 630090 (Russian Federation); Novosibirsk State Technical University, 20 Prospekt K. Marksa, Novosibirsk 630073 (Russian Federation); Leonov, V.V. [Budker Institute of Nuclear Physics, Lavrentiev ave. 11, Novosibirsk 630090 (Russian Federation); Oleynikov, V.P. [Budker Institute of Nuclear Physics, Lavrentiev ave. 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State University, Pirogova st. 2, Novosibirsk 630090 (Russian Federation); Porosev, V.V., E-mail: porosev@inp.nsk.su [Budker Institute of Nuclear Physics, Lavrentiev ave. 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State University, Pirogova st. 2, Novosibirsk 630090 (Russian Federation); Savinov, G.A. [Budker Institute of Nuclear Physics, Lavrentiev ave. 11, Novosibirsk 630090 (Russian Federation)

    2017-02-11

    X-ray detectors operating in the energy integrating mode are successfully used in many different applications. Nevertheless the direct photon counting detectors, having the superior parameters in comparison with the integrating ones, are rarely used yet. One of the reasons for this is the low value of the electrical signal generated by a detected photon. Silicon photomultiplier (SiPM) based scintillation counters have a high detection efficiency, high electronic gain and compact dimensions. This makes them a very attractive candidate to replace routinely used detectors in many fields. More than 10 years ago the digital scanning radiography system based on multistrip ionization chamber (MIC) was suggested at Budker Institute of Nuclear Physics. The detector demonstrates excellent radiation resistance and parameter stability after 5 year operations and an imaging of up to 1000 persons per day. Currently, the installations operate at several Russian airports and at subway stations in some cities. At the present time we design a new detector operating in the photon counting mode, having superior parameters than the gas one, based on scintillator – SiPM assemblies. This detector has close to zero noise, higher quantum efficiency and a count rate capability of more than 5 MHz per channel (20% losses), which leads to better image quality and improved detection capability. The suggested detector technology could be expanded to medical applications.

  19. Photon counting detector for the personal radiography inspection system “SIBSCAN”

    International Nuclear Information System (INIS)

    Babichev, E.A.; Baru, S.E.; Grigoriev, D.N.; Leonov, V.V.; Oleynikov, V.P.; Porosev, V.V.; Savinov, G.A.

    2017-01-01

    X-ray detectors operating in the energy integrating mode are successfully used in many different applications. Nevertheless the direct photon counting detectors, having the superior parameters in comparison with the integrating ones, are rarely used yet. One of the reasons for this is the low value of the electrical signal generated by a detected photon. Silicon photomultiplier (SiPM) based scintillation counters have a high detection efficiency, high electronic gain and compact dimensions. This makes them a very attractive candidate to replace routinely used detectors in many fields. More than 10 years ago the digital scanning radiography system based on multistrip ionization chamber (MIC) was suggested at Budker Institute of Nuclear Physics. The detector demonstrates excellent radiation resistance and parameter stability after 5 year operations and an imaging of up to 1000 persons per day. Currently, the installations operate at several Russian airports and at subway stations in some cities. At the present time we design a new detector operating in the photon counting mode, having superior parameters than the gas one, based on scintillator – SiPM assemblies. This detector has close to zero noise, higher quantum efficiency and a count rate capability of more than 5 MHz per channel (20% losses), which leads to better image quality and improved detection capability. The suggested detector technology could be expanded to medical applications.

  20. Performance evaluation of flat panel detector in x-ray fluoroscopy

    International Nuclear Information System (INIS)

    Grewal, R.K.; Mclean, I.D.

    2004-01-01

    Full text: Flat panel detectors are currently replacing the conventional image intensifiers in R-F imaging. We evaluated the performance of a biplane cardiac imaging system (Siemens Axiom Artis dBC), the image acquisition was based on a 25 cm diagonal digital fiat panel detector. Performance characteristics included image quality, typical patient entrance dose and measurement of input to the surface of flat detector. The results were compared with conventional image intensifier systems (Siemens Hicor Unit and Toshiba DPF 2000 A Biplane Unit) used in cardiac imaging at Westmead. Image quality and dose measurements were performed following standard protocols using Westmead test object and 20 cm solid water as absorber in the beam. For measurement of input to the surface of flat detector, 2 mm copper was placed on the collimator. Radcal 3cc and 180 cc ion chambers were used for dose measurements. Image quality: Our measurements on flat panel system indicate that high contrast resolution and threshold contrast is not affected by changing field size. This is expected due to minimum loss of signal in the imaging chain of digital systems and the independence of detector pixel size with change in field of view. While low contrast resolution was found to be similar to conventional systems, high contrast resolution was significantly superior using flat detector system for large and intermediate field of view (25-28 1p/cm against 18-20). Typical patient dose as measured using flat detector system was similar to the conventional Toshiba pulsed fluoroscopy system( ∼ 3 - 8 mGy/min depending on the field size). This was 40-50 % lower than our old Siemens hicore unit. Input to the surface of flat detector was found to vary with field size as is the case with a conventional II system. As described elsewhere, although there is no necessity to increase exposure or video gain in a digital magnification, digital data interpolation process introduces noise. As a result system

  1. Test experiments on muon radiography with emulsion track detectors in Russia

    International Nuclear Information System (INIS)

    Aleksandrov, A.B.; Bagulya, A.V.; Vladimirov, M.S.

    2015-01-01

    The Lebedev Physical Institute of the Russian Academy of Sciences (FIAN) and the Skobeltsyn Institute of Nuclear Physics of the Lomonosov Moscow State University (SINP MSU) opened in Russia a series of pilot muon radiography experiments with nuclear emulsion detectors for study of interior structure of large-scale natural and industrial objects. As a result the optimal conditions of experiment organization were determined, algorithms of data processing were worked out and peculiarities of the method were ultimately investigated. The experiment data, including field observations (in the mine of the Geophysical Department of the Russian Academy of Sciences), were also presented which confirm that the method with track detectors on the base of nuclear emulsions with uniquely high spatial resolution holds much promise in case of their high-tech automated processing

  2. A semiempirical linear model of indirect, flat-panel x-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Shih-Ying; Yang Kai; Abbey, Craig K.; Boone, John M. [Department of Biomedical Engineering, University of California, Davis, California, One Shields Avenue, Davis, California 95616 (United States) and Department of Radiology, University of California, Davis, Medical Center, 4860 Y Street, Ambulatory Care Center Suite 0505, Sacramento, California 95817 (United States); Department of Radiology, University of California, Davis, Medical Center, 4860 Y Street, Ambulatory Care Center Suite 0505, Sacramento, California 95817 (United States); Department of Psychological and Brain Sciences, University of California, Santa Barbara, California 92106 (United States); Department of Biomedical Engineering, University of California, Davis, California, One Shields Avenue, Davis, California 95616 (United States) and Department of Radiology, University of California, Davis, Medical Center, 4860 Y Street, Ambulatory Care Center Suite 3100, Sacramento, California 95817 (United States)

    2012-04-15

    Purpose: It is important to understand signal and noise transfer in the indirect, flat-panel x-ray detector when developing and optimizing imaging systems. For optimization where simulating images is necessary, this study introduces a semiempirical model to simulate projection images with user-defined x-ray fluence interaction. Methods: The signal and noise transfer in the indirect, flat-panel x-ray detectors is characterized by statistics consistent with energy-integration of x-ray photons. For an incident x-ray spectrum, x-ray photons are attenuated and absorbed in the x-ray scintillator to produce light photons, which are coupled to photodiodes for signal readout. The signal mean and variance are linearly related to the energy-integrated x-ray spectrum by empirically determined factors. With the known first- and second-order statistics, images can be simulated by incorporating multipixel signal statistics and the modulation transfer function of the imaging system. To estimate the semiempirical input to this model, 500 projection images (using an indirect, flat-panel x-ray detector in the breast CT system) were acquired with 50-100 kilovolt (kV) x-ray spectra filtered with 0.1-mm tin (Sn), 0.2-mm copper (Cu), 1.5-mm aluminum (Al), or 0.05-mm silver (Ag). The signal mean and variance of each detector element and the noise power spectra (NPS) were calculated and incorporated into this model for accuracy. Additionally, the modulation transfer function of the detector system was physically measured and incorporated in the image simulation steps. For validation purposes, simulated and measured projection images of air scans were compared using 40 kV/0.1-mm Sn, 65 kV/0.2-mm Cu, 85 kV/1.5-mm Al, and 95 kV/0.05-mm Ag. Results: The linear relationship between the measured signal statistics and the energy-integrated x-ray spectrum was confirmed and incorporated into the model. The signal mean and variance factors were linearly related to kV for each filter material (r

  3. A semiempirical linear model of indirect, flat-panel x-ray detectors

    International Nuclear Information System (INIS)

    Huang, Shih-Ying; Yang Kai; Abbey, Craig K.; Boone, John M.

    2012-01-01

    Purpose: It is important to understand signal and noise transfer in the indirect, flat-panel x-ray detector when developing and optimizing imaging systems. For optimization where simulating images is necessary, this study introduces a semiempirical model to simulate projection images with user-defined x-ray fluence interaction. Methods: The signal and noise transfer in the indirect, flat-panel x-ray detectors is characterized by statistics consistent with energy-integration of x-ray photons. For an incident x-ray spectrum, x-ray photons are attenuated and absorbed in the x-ray scintillator to produce light photons, which are coupled to photodiodes for signal readout. The signal mean and variance are linearly related to the energy-integrated x-ray spectrum by empirically determined factors. With the known first- and second-order statistics, images can be simulated by incorporating multipixel signal statistics and the modulation transfer function of the imaging system. To estimate the semiempirical input to this model, 500 projection images (using an indirect, flat-panel x-ray detector in the breast CT system) were acquired with 50-100 kilovolt (kV) x-ray spectra filtered with 0.1-mm tin (Sn), 0.2-mm copper (Cu), 1.5-mm aluminum (Al), or 0.05-mm silver (Ag). The signal mean and variance of each detector element and the noise power spectra (NPS) were calculated and incorporated into this model for accuracy. Additionally, the modulation transfer function of the detector system was physically measured and incorporated in the image simulation steps. For validation purposes, simulated and measured projection images of air scans were compared using 40 kV/0.1-mm Sn, 65 kV/0.2-mm Cu, 85 kV/1.5-mm Al, and 95 kV/0.05-mm Ag. Results: The linear relationship between the measured signal statistics and the energy-integrated x-ray spectrum was confirmed and incorporated into the model. The signal mean and variance factors were linearly related to kV for each filter material (r 2 of

  4. A semiempirical linear model of indirect, flat-panel x-ray detectors.

    Science.gov (United States)

    Huang, Shih-Ying; Yang, Kai; Abbey, Craig K; Boone, John M

    2012-04-01

    It is important to understand signal and noise transfer in the indirect, flat-panel x-ray detector when developing and optimizing imaging systems. For optimization where simulating images is necessary, this study introduces a semiempirical model to simulate projection images with user-defined x-ray fluence interaction. The signal and noise transfer in the indirect, flat-panel x-ray detectors is characterized by statistics consistent with energy-integration of x-ray photons. For an incident x-ray spectrum, x-ray photons are attenuated and absorbed in the x-ray scintillator to produce light photons, which are coupled to photodiodes for signal readout. The signal mean and variance are linearly related to the energy-integrated x-ray spectrum by empirically determined factors. With the known first- and second-order statistics, images can be simulated by incorporating multipixel signal statistics and the modulation transfer function of the imaging system. To estimate the semiempirical input to this model, 500 projection images (using an indirect, flat-panel x-ray detector in the breast CT system) were acquired with 50-100 kilovolt (kV) x-ray spectra filtered with 0.1-mm tin (Sn), 0.2-mm copper (Cu), 1.5-mm aluminum (Al), or 0.05-mm silver (Ag). The signal mean and variance of each detector element and the noise power spectra (NPS) were calculated and incorporated into this model for accuracy. Additionally, the modulation transfer function of the detector system was physically measured and incorporated in the image simulation steps. For validation purposes, simulated and measured projection images of air scans were compared using 40 kV∕0.1-mm Sn, 65 kV∕0.2-mm Cu, 85 kV∕1.5-mm Al, and 95 kV∕0.05-mm Ag. The linear relationship between the measured signal statistics and the energy-integrated x-ray spectrum was confirmed and incorporated into the model. The signal mean and variance factors were linearly related to kV for each filter material (r(2) of signal mean to k

  5. Image quality and dose management in digital radiography: A new paradigm for optimisation

    International Nuclear Information System (INIS)

    Busch, H. P.; Faulkner, K.

    2005-01-01

    The advent of digital imaging in radiology, combined with the explosive growth of technology, has dramatically improved imaging techniques. This has led to the expansion of diagnostic capabilities, both in terms of the number of procedures and their scope. Throughout the world, film/ screen radiography systems are being rapidly replaced with digital systems. Many progressive medical institutions have acquired, or are considering the purchase of computed radiography systems with storage phosphor plates or direct digital radiography systems with flat panel detectors. However, unknown to some users, these devices offer a new paradigm of opportunity and challenges. Images can be obtained at a lower dose owing to the higher detective quantum efficiency (DQE). These fundamental differences in comparison to conventional film/screens necessitate the development of new strategies for dose and quality optimisations. A set of referral criteria based upon three dose levels is proposed. (authors)

  6. A multi-panel direction-sensitive gamma-ray detector for low-altitude radiological searches

    Energy Technology Data Exchange (ETDEWEB)

    Becker, E.M.; Farsoni, A.T.

    2016-11-11

    A lightweight, low-cost multi-panel direction-sensitive radiation detector prototype has been developed at Oregon State University that is designed to be mounted on a small unmanned aerial system to autonomously search for radiation sources while flying close to the ground. The detection system comprises sixteen BGO-SiPM detector panels with an adjustable view angle, and signal outputs are processed in parallel in an FPGA. The minimum detectable activity was calculated to be 1.3 μCi of {sup 137}Cs at 1 m in under 60 s. The counting response of the detector panels were characterized and found to have 4.7% relative standard deviation, indicating good uniformity in overall design and assembly. The detector was also able to estimate the direction of a 12.3 μCi {sup 137}Cs source 100 cm from the device center with 2.3° accuracy in a 95% confidence width of 10.8° in 60 s.

  7. Digital radiography: description and user's guide

    Energy Technology Data Exchange (ETDEWEB)

    Berthel, A. [Cryospace, 78 - Les Mureaux (France); Bonin, Th. [CEA Valduc, 21 - Is-sur-Tille (France); Cadilhon, S.; Thiery, Ch. [CEA Bruyeres-le-Chatel, 91 (France); Chatellier, L. [Electricite de France (EDF-RD), Recherche et Developpement, 78 - Chatou (France); Kaftandjian, V. [Lyon Univ., INSA Lab. Controle Non Destructif par Rayonnements Ionisants (CNDRI), 69 (France); Honorat, Ph.; Torrent, J. [SNECMA, 75 - Paris (France); Le Brun, A. [Electricite de France, 78 - Chatou (France); Maglaive, J.C. [Euromev, 78 - Buc (France); Moreau, Ph. [General Electric Industrial Inspection Technologies, 69 - Limonest (France); Pettier, J.L. [CEA Cadarach, Dir. de l' Energie Nucleaire, 13 - Saint Paul lez Durance (France); Rebuffel, V. [CEA Grenoble, Lab. d' Electronique et de Technologie de l' Informatique (LETI), 38 (France); Roenelle, P. [Centre d' Etudes Techniques de l' Equipement, 69 - Bron Lyon (France); Roussilhe, J. [Carestream Health France SA, 71 - Chalon/Saone (France); Staat, St.; Tahon, M. [Cegelec, 91 - Bretigny sur Orge (France)

    2007-07-01

    The presented document arises from the work of the group 'Digital Radiography and sensors' of COFREND. It is a collective work of synthesis aimed to analyze the quality parameters of digital images influencing the answer and the diagnosis brought to a given industrial problem. Five families of digital sensors have been studied: 1. Image Intensifier coupled with CCD devices - 2. scintillators coupled with a CCD device- 3. Flat Panels with indirect conversion - 4. Flat Panels with direct electric conversion - 5. Photostimulable Storage Phosphor Screens). In particular, concerning a complete imaging chain, it deals with the notions of magnification, blur (unsharpness) (geometrical, kinetic or internal to the very sensor), noises, scattered radiation, spatial resolution, which is different from the one of analog detectors such as films, Contrast to Noise Ratio (CNR), sensitivity using IQIs, dynamic range, detection quantum efficiency, persistence and temporal resolution. This document is not a standard; it must be understood as a user's guide, and it approaches some essentials corrections to bring to a sensor in order to optimize his efficiency without losing information during the pre-processing phase in the radiographic acquisition. It also introduces some image processing tools commonly used. It can be used as a source document to the future elaboration of a standardisation document. It augurs not at all of the choice of a digital sensor with regard to the traditional radiographic film, but gives bases of reflection to a radio user for a sensible transfer from the classic radiography to the digital radiography. (authors)

  8. Advances in computed radiography systems and their physical imaging characteristics

    International Nuclear Information System (INIS)

    Cowen, A.R.; Davies, A.G.; Kengyelics, S.M.

    2007-01-01

    Radiological imaging is progressing towards an all-digital future, across the spectrum of medical imaging techniques. Computed radiography (CR) has provided a ready pathway from screen film to digital radiography and a convenient entry point to PACS. This review briefly revisits the principles of modern CR systems and their physical imaging characteristics. Wide dynamic range and digital image enhancement are well-established benefits of CR, which lend themselves to improved image presentation and reduced rates of repeat exposures. However, in its original form CR offered limited scope for reducing the radiation dose per radiographic exposure, compared with screen film. Recent innovations in CR, including the use of dual-sided image readout and channelled storage phosphor have eased these concerns. For example, introduction of these technologies has improved detective quantum efficiency (DQE) by approximately 50 and 100%, respectively, compared with standard CR. As a result CR currently affords greater scope for reducing patient dose, and provides a more substantive challenge to the new solid-state, flat-panel, digital radiography detectors

  9. Neutron-induced alpha radiography

    International Nuclear Information System (INIS)

    Pereira, Marco Antonio Stanojev

    2008-01-01

    A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the α - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70 deg C respectively. For such conditions samples having 10 μm in thickness can be inspected with a spatial resolution of 32 μm. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to β, γ, X-ray and visible light. (author)

  10. Application of GaAs and CdTe photoconductor detectors to x-ray flash radiography

    International Nuclear Information System (INIS)

    Mathy, F.; Cuzin, M.; Gagelin, J.J.; Mermet, R.; Piaget, B.; Rustique, J.; Verger, L.

    1991-01-01

    Semi-insulating GaAs and CdTe:Cl photoconductor probes were qualified on high energy X ray single shot flash generators. The estimated minimum detected dose per flash corresponding to a 230 mrad direct beam attenuated by 200 mm lead was 20 μrad. The dynamic range was about 4 decades in amplitude or charges, with a good linearity. Such detectors, by locating the origin of the parasitic scattered beam, could be used to eliminate this parasitic beam in X ray flash radiography in detonics experiments. Imaging possibilities are mentioned, as well as X ray generator monitoring with such detectors or with neutron preirradiated photoconductors

  11. Application of GaAs and CdTe photoconductor detectors to X-ray flash radiography

    International Nuclear Information System (INIS)

    Mathy, F.; Cuzin, M.; Gagelin, J.J.; Mermet, R.; Piaget, B.; Rustique, J.; Verger, L.; Hauducoeur, A.; Nicolas, P.; Le Dain, L.; Hyvernage, M.

    1992-01-01

    Some insulating GaAs and CdTe:Cl photoconductor probes were qualified on high energy X-ray single-shot flash generators. The estimated minimum detected dose per flash corresponding to a 230 mrad direct beam attenuated by 200 mm lead was 20 μrad. The dynamic range was about 4 decades in amplitude or charge, with a good linearity. Such detectors, by locating the origin of the parasitic scattered beam, could be used to eliminate this parasitic beam in X-ray flash radiography in detonics experiments. Imaging possibilities are mentioned, as well as X-ray generator monitoring with such detectors or with neutron preirradiated photoconductors. (orig.)

  12. Application of GaAs and CdTe photoconductor detectors to X-ray flash radiography

    Energy Technology Data Exchange (ETDEWEB)

    Mathy, F.; Cuzin, M.; Gagelin, J.J.; Mermet, R.; Piaget, B.; Rustique, J.; Verger, L. (CEA, Direction des Technologies Avancees, Lab. d' Electronique, de Technologie et d' Instrumentation, DSYS, 38 - Grenoble (France)); Hauducoeur, A.; Nicolas, P.; Le Dain, L.; Hyvernage, M. (CEA, Direction des Applications Militaires, 77 - Courtry (France))

    1992-11-15

    Some insulating GaAs and CdTe:Cl photoconductor probes were qualified on high energy X-ray single-shot flash generators. The estimated minimum detected dose per flash corresponding to a 230 mrad direct beam attenuated by 200 mm lead was 20 [mu]rad. The dynamic range was about 4 decades in amplitude or charge, with a good linearity. Such detectors, by locating the origin of the parasitic scattered beam, could be used to eliminate this parasitic beam in X-ray flash radiography in detonics experiments. Imaging possibilities are mentioned, as well as X-ray generator monitoring with such detectors or with neutron preirradiated photoconductors. (orig.).

  13. Application of GaAs and CdTe photoconductor detectors to x-ray flash radiography

    Energy Technology Data Exchange (ETDEWEB)

    Mathy, F.; Cuzin, M.; Gagelin, J.J.; Mermet, R.; Piaget, B.; Rustique, J.; Verger, L. [CEA Centre d`Etudes de Grenoble, 38 (FR). Direction des Technologies Avancees; Hauducoeur, A.; Nicolas, P.; Le Dain, L.; Hyvernage, M. [CEA Centre d`Etudes de Vaujours, 77 - Courtry (FR)

    1991-12-31

    Semi-insulating GaAs and CdTe:Cl photoconductor probes were qualified on high energy X ray single shot flash generators. The estimated minimum detected dose per flash corresponding to a 230 mrad direct beam attenuated by 200 mm lead was 20 {mu}rad. The dynamic range was about 4 decades in amplitude or charges, with a good linearity. Such detectors, by locating the origin of the parasitic scattered beam, could be used to eliminate this parasitic beam in X ray flash radiography in detonics experiments. Imaging possibilities are mentioned, as well as X ray generator monitoring with such detectors or with neutron preirradiated photoconductors.

  14. Practical evaluation of clinical image quality (4). Determination of image quality in digital radiography system

    International Nuclear Information System (INIS)

    Katayama, Reiji

    2016-01-01

    Recently, for medical imaging, digital radiography systems are widely used in clinical practices. However, a study in the past reported that a patient radiation exposure level by digital radiography is in fact not lower than that by analog radiography system. High level of attention needs to be paid for over-exposure when using the conventional analog radiography with a screen and a film, as it results in high density of the film. However, for digital radiography systems, since the automatic adjusting function of image density is equipped with them, no attention for radiation dose need to be paid. Thus technologists tend to be careless and results in higher chance for over-exposure. Current digital radiography systems are high-performance in the image properties and capable of patient dose reduction. Especially, the image quality of the flat panel detector system is recognized, higher than that of the computed radiography system by imaging plates, in both objective and subjective evaluations. Therefore, we technologists are responsible for optimizing the balance between the image quality of the digital radiogram and the radiation dose required for each case. Moreover, it is also required for us as medical technologists to make effective use of such evaluation result of medical images for patients. (author)

  15. On the performance of the noise power spectrum from the gain-corrected radiography images.

    Science.gov (United States)

    Kim, Dong Sik; Lee, Eunae

    2018-01-01

    Fixed pattern noise due to nonuniform amplifier gains and scintillator sensitivity should be alleviated in radiography imaging to acquire low-noise x-ray images from detectors. Here, the noise property of the detector is usually evaluated observing the noise power spectrum (NPS). A gain-correction scheme, in which uniformly illuminated images are averaged to design a gain map, can be applied to alleviate the fixed pattern noise problem. The normalized NPS (NNPS) of the gain-corrected image decreases as the number of images for the average increases and converges to an infimum, which can be achieved if the fixed pattern noise is completely removed. If we know the NNPS infimum of the detector, then we can determine the performance of the gain-corrected images compared with the achievable lower bound. We first construct an image-formation model considering the nonuniform gain and then consider two measurement methods based on subtraction and division to estimate the NNPS infimum of the detector. In order to obtain a high-precision NNPS infimum estimate, we consider a time-averaging method. For several flat-panel radiography detectors, we constructed the NNPS infimum measurements and compared them with NNPS values of the gain-corrected images. We observed that the NNPS values of the gain-corrected images approached the NNPS infimum as the number of images for the average increased.

  16. Plasma Panel Detectors for MIP Detection for the SLHC and a Test Chamber Design

    CERN Document Server

    Ball, Robert; Etzion, Erez; Friedman, Peter S; Levin, Daniel S; Moshe, Meny Ben; Weaverdyck, Curtis; Zhou, Bing

    2010-01-01

    Performance demands for high and super-high luminosity at the LHC (up to 10^35 cm^(-2) sec^(-1) after the 2017 shutdown) and at future colliders demand high resolution tracking detectors with very fast time response and excellent temporal and spatial resolution. We are investigating a new radiation detector technology based on Plasma Display Panels (PDP), the underlying engine of panel plasma television displays. The design and production of PDPs is supported by four decades of industrial development. Emerging from this television technology is the Plasma Panel Sensor (PPS), a novel variant of the micropattern radiation detector. The PPS is fundamentally an array of micro-Geiger plasma discharge cells operating in a non-ageing, hermetically sealed gas mixture . We report on the PPS development program, including design of a PPS Test Cell.

  17. Imaging responses of on-site CsI and Gd2O2S flat-panel detectors: Dependence on the tube voltage

    Science.gov (United States)

    Jeon, Hosang; Chung, Myung Jin; Youn, Seungman; Nam, Jiho; Lee, Jayoung; Park, Dahl; Kim, Wontaek; Ki, Yongkan; Kim, Ho Kyung

    2015-07-01

    One of the emerging issues in radiography is low-dose imaging to minimize patient's exposure. The scintillating materials employed in most indirect flat-panel detectors show a drastic change of X-ray photon absorption efficiency around their K-edge energies that consequently affects image quality. Using various tube voltages, we investigated the imaging performance of most popular scintillators: cesium iodide (CsI) and gadolinium oxysulfide (Gd2O2S). The integrated detective quantum efficiencies (iDQE) of four detectors installed in the same hospital were evaluated according to the standardized procedure IEC 62220-1 at tube voltages of 40 - 120 kVp. The iDQE values of the Gd2O2S detectors were normalized by those of CsI detectors to exclude the effects of image postprocessing. The contrast-to-noise ratios (CNR) were also evaluated by using an anthropomorphic chest phantom. The iDQE of the CsI detector outperformed that of the Gd2O2S detector over all tube voltages. Moreover, we noted that the iDQE of the Gd2O2S detectors quickly rolled off with decreasing tube voltage under 70 kVp. The CNRs of the two scintillators were similar at 120 kVp. At 60 kVp, however, the CNR of Gd2O2S was about half that of CsI. Compared to the Gd2O2S detectors, variations in the DQE performance of the CsI detectors were relatively immune to variations in the applied tube voltages. Therefore, we claim that Gd2O2S detectors are inappropriate for use in low-tube-voltage imaging (e.g., extremities and pediatrics) with low patient exposure.

  18. Recent developments in radiography

    International Nuclear Information System (INIS)

    Berger, Harold

    1982-01-01

    Advances in radiography are reviewed and eighty-one references are cited to provide additional information. The review includes information on x-ray sources in terms of output, portability and imaging geometry and detectors in terms of films and screens, electrostatic methods, real-time techniques and solid state devices. Inspection methods utilizing radiations other than x-rays, neutrons and charged particles, expand the inspection problems suitable for radiography. Techniques such as tomography, digital radiography and image enhancement are described. Tomography, in particular, provides excellent capability to characterize materials and discontinuities

  19. Radiation dose of digital tomosynthesis for sinonasal examination: comparison with multi-detector CT.

    Science.gov (United States)

    Machida, Haruhiko; Yuhara, Toshiyuki; Tamura, Mieko; Numano, Tomokazu; Abe, Shinji; Sabol, John M; Suzuki, Shigeru; Ueno, Eiko

    2012-06-01

    Using an anthropomorphic phantom, we have investigated the feasibility of digital tomosynthesis (DT) of flat-panel detector (FPD) radiography to reduce radiation dose for sinonasal examination compared to multi-detector computed tomography (MDCT). A female Rando phantom was scanned covering frontal to maxillary sinus using the clinically routine protocol by both 64-detector CT (120 kV, 200 mAs, and 1.375-pitch) and DT radiography (80 kV, 1.0 mAs per projection, 60 projections, 40° sweep, and posterior-anterior projections). Glass dosimeters were used to measure the radiation dose to internal organs including the thyroid gland, brain, submandibular gland, and the surface dose at various sites including the eyes during those scans. We compared the radiation dose to those anatomies between both modalities. In DT radiography, the doses of the thyroid gland, brain, submandibular gland, skin, and eyes were 230 ± 90 μGy, 1770 ± 560 μGy, 1400 ± 80 μGy, 1160 ± 2100 μGy, and 112 ± 6 μGy, respectively. These doses were reduced to approximately 1/5, 1/8, 1/12, 1/17, and 1/290 of the respective MDCT dose. For sinonasal examinations, DT radiography enables dramatic reduction in radiation exposure and dose to the head and neck region, particularly to the lens of the eye. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  20. A Nuclear Emulsion Detector for the Muon Radiography of a Glacier Structure

    Directory of Open Access Journals (Sweden)

    Akitaka Ariga

    2018-04-01

    Full Text Available Cosmic ray muons can be used to image the interior of geological sites provided that one employs detectors able to operate in the specific harsh conditions of the mountain environment. We designed and developed a detector exploiting the nuclear emulsion technique to assess the bedrock profile underneath an alpine glacier. Nuclear emulsions do not need any electric power supply or maintenance and allow for the measurement of the muon flux and direction behind a large target volume. The 3D density distribution of the material traversed by muons can then be assessed, bringing relevant information on the shape of the boundary between the glacial ice and the underlying bedrock. This new methodology in the geological field was recently tested in a campaign of measurements in the Jungfrau region of the central Swiss Alps. It was shown that the bedrock surface position can be measured with a resolution of about 5 % when the traversed target is about 100 m thick. Characteristics and performance of the method are reported here and demonstrate that muon radiography based on emulsion detectors represents a powerful tool for the geological study of glaciers.

  1. Panel on accelerators and detectors in the 1950s

    International Nuclear Information System (INIS)

    Jones, L.W.; Amaldi, U.; Hofstadter, R.; Kerst, D.W.; Wilson, R.R.

    1989-01-01

    The article takes the form of a panel of famous particle physics scientists discussing accelerator design and detectors used in the 1950s. The discussion ranges over accelerator energy capacities, the invention of alternating-gradient focusing, and colliding beam machines, beam stacking and the application of digital computers to accelerator calculations. The development of particle beams using strong-focusing lenses and electrostatic separators rounded off the decade. Detectors moved from bubble chambers, the use of plastic and inorganic scintillators, to hadron calorimeters, Cherenkov counters and finally spark chambers. Various discoveries made using sodium iodide scintillation counters are noted. (UK)

  2. Real-time radiography

    International Nuclear Information System (INIS)

    Bossi, R.H.; Oien, C.T.

    1981-01-01

    Real-time radiography is used for imaging both dynamic events and static objects. Fluorescent screens play an important role in converting radiation to light, which is then observed directly or intensified and detected. The radiographic parameters for real-time radiography are similar to conventional film radiography with special emphasis on statistics and magnification. Direct-viewing fluoroscopy uses the human eye as a detector of fluorescent screen light or the light from an intensifier. Remote-viewing systems replace the human observer with a television camera. The remote-viewing systems have many advantages over the direct-viewing conditions such as safety, image enhancement, and the capability to produce permanent records. This report reviews real-time imaging system parameters and components

  3. Flat-Panel Computed Tomography (DYNA-CT) in Neuroradiology. From High-Resolution Imaging of Implants to One-Stop-Shopping for Acute Stroke.

    Science.gov (United States)

    Doerfler, A; Gölitz, P; Engelhorn, T; Kloska, S; Struffert, T

    2015-10-01

    Originally aimed at improving standard radiography by providing higher absorption efficiency and a wider dynamic range, flat-panel detector technology has meanwhile got widely accepted in the neuroradiological community. Especially flat-panel detector computed tomography (FD-CT) using rotational C-arm mounted flat-panel detector technology is capable of volumetric imaging with a high spatial resolution. By providing CT-like images of the brain within the angio suite, FD-CT is able to rapidly visualize hemorrhage and may thus improve complication management without the need of patient transfer. As "Angiographic CT" FD-CT may be helpful during many diagnostic and neurointerventional procedures and for noninvasive monitoring and follow-up. In addition, spinal interventions and high-resolution imaging of the temporal bone might also benefit from FD-CT. Finally, using novel dynamic perfusion and angiographic protocols, FD-CT may provide functional information on brain perfusion and vasculature with the potential to replace standard imaging in selected acute stroke patients.

  4. Time-Resolved Quantitative Analysis of the Diaphragms During Tidal Breathing in a Standing Position Using Dynamic Chest Radiography with a Flat Panel Detector System ("Dynamic X-Ray Phrenicography"): Initial Experience in 172 Volunteers.

    Science.gov (United States)

    Yamada, Yoshitake; Ueyama, Masako; Abe, Takehiko; Araki, Tetsuro; Abe, Takayuki; Nishino, Mizuki; Jinzaki, Masahiro; Hatabu, Hiroto; Kudoh, Shoji

    2017-04-01

    Diaphragmatic motion in a standing position during tidal breathing remains unclear. The purpose of this observational study was to evaluate diaphragmatic motion during tidal breathing in a standing position in a health screening center cohort using dynamic chest radiography in association with participants' demographic characteristics. One hundred seventy-two subjects (103 men; aged 56.3 ± 9.8 years) underwent sequential chest radiographs during tidal breathing using dynamic chest radiography with a flat panel detector system. We evaluated the excursions of and peak motion speeds of the diaphragms. Associations between the excursions and participants' demographics (gender, height, weight, body mass index [BMI], smoking history, tidal volume, vital capacity, and forced expiratory volume) were investigated. The average excursion of the left diaphragm (14.9 ± 4.6 mm, 95% CI 14.2-15.5 mm) was significantly larger than that of the right (11.0 ± 4.0 mm, 95% CI 10.4-11.6 mm) (P <0.001). The peak motion speed of the left diaphragm (inspiratory, 16.6 ± 4.2 mm/s; expiratory, 13.7 ± 4.2 mm/s) was significantly faster than that of the right (inspiratory, 12.4 ± 4.4 mm/s; expiratory, 9.4 ± 3.8 mm/s) (both P <0.001). Both simple and multiple regression models demonstrated that higher BMI and higher tidal volume were associated with increased excursions of the bilateral diaphragm (all P <0.05). The average excursions of the diaphragms are 11.0 mm (right) and 14.9 mm (left) during tidal breathing in a standing position. The diaphragmatic motion of the left is significantly larger and faster than that of the right. Higher BMI and tidal volume are associated with increased excursions of the bilateral diaphragm. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  5. Flat-detector computed tomography in diagnostic and interventional neuroradiology

    International Nuclear Information System (INIS)

    Struffert, T.; Doerfler, A.

    2009-01-01

    Originally aimed at improving standard radiography by providing higher absorption efficiency and a wider dynamic range than available with film-screen and phosphor luminescence, radiography flat detector technology is now widely accepted for neuroangiographic imaging. Especially flat-detector computed tomography (FD-CT), which uses rotational C-arm mounted flat-panel detector technology, is capable of volumetric imaging with a high spatial resolution. As ''angiographic CT'' FD-CT may be helpful in many diagnostic and neurointerventional procedures, e.g. intracranial stenting for cerebrovascular stenoses, stent-assisted coil embolization of wide-necked cerebral aneurysms and embolization of arteriovenous malformations. By providing morphologic, CT-like images of the brain within the angiography suite FD-CT allows rapid visualization of periprocedural hemorrhaging and may thus improve rapid complication management without the need of patient transfer. In addition, myelography and postmyelographic FD-CT imaging can be carried out using a single modality. Spinal interventions, such as kyphoplasty or vertebroplasty might also benefit from FD-CT. Imaging of the temporal bone may also develop into an important field of FD-CT. This paper briefly reviews the technical principles of FD technology and the potential applications in diagnostic and interventional neuroradiology. (orig.) [de

  6. Radiography imaging by 64 and 128 micro-strips crystalline detectors at different X-ray energies

    International Nuclear Information System (INIS)

    Leyva, A.; Cabal, A.; Montano, L. M.; Fontaine, M.; Mora, R. de la; Padilla, F.

    2006-01-01

    This paper summarizes some results obtained in the evaluation of the performance of position sensitive detectors in track reconstruction in particle physics experiments. Crystalline silicon micro-strips detectors with 64 and 128 channels and 100 μm pitch were used to obtain radiographic digital images of different objects. The more relevant figures for spectrometry applications were measured and reported. Two-dimensional images were obtained by scanning the object with a collimated beam using different source-target-detector positioning and three sources of X-rays (8.04, 18.55 and 22.16 keV). The counts acquired by each strip correspond to a particular collimator position during the scan, thus serving to reconstruct the image of the exposed to X-ray object and to reveal its internal structure. The use of some techniques for image processing allow the further improvement of the radiography quality. The preliminary results obtained using in-house made and accreditation mammography phantoms allow to infer that such detectors can be successfully introduced in the digital mammography practice. (Author)

  7. Development of a Two-Dimensional Tracker with Plasma Panel Detector

    CERN Document Server

    AUTHOR|(CDS)2233132

    Plasma panel sensors are micropattern gaseous radiation detectors which are based on the technology of plasma display panels. This thesis summarizes the research that had been done on commercially available plasma display panels that were converted to plasma panel sensor prototypes and describes the construction of a two-dimensional tracker consisting of four of those prototypes, with one-dimensional readout on each, used to detect tracks of cosmic muons. A large amount of 2-point as well as 3 and 4-point tracks were detected. Qualitative analyses as well as Pearson’s χ2 tests are performed on the track angular distribution and on a histogram of the linearity measure of 3-point tracks to reject the hypothesis that these tracks result from completely random panel hits. Some RF noise effects contributing to false positives are ruled out, while it is shown that other effects can be ruled out only with a high-intensity minimum ionizing particle source. A significant part of the tracker construction was the dev...

  8. Muon radiography method for fundamental and applied research

    Science.gov (United States)

    Alexandrov, A. B.; Vladymyrov, M. S.; Galkin, V. I.; Goncharova, L. A.; Grachev, V. M.; Vasina, S. G.; Konovalova, N. S.; Malovichko, A. A.; Managadze, A. K.; Okat'eva, N. M.; Polukhina, N. G.; Roganova, T. M.; Starkov, N. I.; Tioukov, V. E.; Chernyavsky, M. M.; Shchedrina, T. V.

    2017-12-01

    This paper focuses on the basic principles of the muon radiography method, reviews the major muon radiography experiments, and presents the first results in Russia obtained by the authors using this method based on emulsion track detectors.

  9. Digital radiography

    International Nuclear Information System (INIS)

    Coulomb, M.; Dal Soglio, S.; Pittet-Barbier, L.; Ranchoup, Y.; Thony, F.; Ferretti, G.; Robert, F.

    1992-01-01

    Digital projection radiography may replace conventional radiography some day, provided it can meet several requirements: equal or better diagnostic effectiveness of the screen-film systems; reasonable image cost; real improvement in the productivity of the Departments of Imaging. All digital radiographic systems include an X-ray source, an image acquisition and formatting sub-system, a display and manipulation sub-system, and archiving subsystem and a laser editing system, preferably shared by other sources of digital images. Three digitization processes are available: digitization of the radiographic film, digital fluorography and phospholuminescent detectors with memory. The advantages of digital fluoroscopy are appealing: real-time image acquisition, suppression of cassettes; but its disadvantages are far from negligible: it cannot be applied to bedside radiography, the field of examination is limited, and the wide-field spatial resolution is poor. Phospholuminescent detectors with memory have great advantages: they can be used for bedside radiographs and on all the common radiographic systems; spatial resolution is satisfactory; its current disadvantages are considerable. These two systems, have common properties making up the entire philosophy of digital radiology and specific features that must guide our choice according to the application. Digital fluorography is best applied in pediatric radiology. However, evaluation works have showed that it was applicable with sufficient quality to many indications of general radiology in which a fluoroscopic control and fast acquisition of the images are essential; the time gained on the examination may be considerable, as well as the savings on film. Detectors with memory are required for bedside radiographs, in osteoarticular and thoracic radiology, in all cases of traumatic emergency and in the resuscitation and intensive care departments

  10. Difference in the craniocaudal gradient of the maximum pixel value change rate between chronic obstructive pulmonary disease patients and normal subjects using sub-mGy dynamic chest radiography with a flat panel detector system.

    Science.gov (United States)

    Yamada, Yoshitake; Ueyama, Masako; Abe, Takehiko; Araki, Tetsuro; Abe, Takayuki; Nishino, Mizuki; Jinzaki, Masahiro; Hatabu, Hiroto; Kudoh, Shoji

    2017-07-01

    To compare the craniocaudal gradients of the maximum pixel value change rate (MPCR) during tidal breathing between chronic obstructive pulmonary disease (COPD) patients and normal subjects using dynamic chest radiography. This prospective study was approved by the institutional review board and all participants provided written informed consent. Forty-three COPD patients (mean age, 71.6±8.7 years) and 47 normal subjects (non-smoker healthy volunteers) (mean age, 54.8±9.8 years) underwent sequential chest radiographs during tidal breathing in a standing position using dynamic chest radiography with a flat panel detector system. We evaluated the craniocaudal gradient of MPCR. The results were analyzed using an unpaired t-test and the Tukey-Kramer method. The craniocaudal gradients of MPCR in COPD patients were significantly lower than those in normal subjects (right inspiratory phase, 75.5±48.1 vs. 108.9±42.0s -1 cm -1 , P<0.001; right expiratory phase, 66.4±40.6 vs. 89.8±31.6s -1 cm -1 , P=0.003; left inspiratory phase, 75.5±48.2 vs. 108.2±47.2s -1 cm -1 , P=0.002; left expiratory phase, 60.9±38.2 vs. 84.3±29.5s -1 cm -1 , P=0.002). No significant differences in height, weight, or BMI were observed between COPD and normal groups. In the sub-analysis, the gradients in severe COPD patients (global initiative for chronic obstructive lung disease [GOLD] 3 or 4, n=26) were significantly lower than those in mild COPD patients (GOLD 1 or 2, n=17) for both right and left inspiratory/expiratory phases (all P≤0.005). A decrease of the craniocaudal gradient of MPCR was observed in COPD patients. The craniocaudal gradient was lower in severe COPD patients than in mild COPD patients. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  11. New developments in radiography. An overview

    International Nuclear Information System (INIS)

    Berger, H.; Orphan, V.

    1983-01-01

    Techniques for radiographic inspection are undergoing change. Changes in X-ray sources include higher voltage and current, pulse techniques, smaller focal spots, portability, ease-of-use, and high reliability. Detector improvements include better films, screens and scintillators, real-time methods, electrostatic methods and solid state detectors. We now use many radiation for radiography (X-rays, gamma rays, neutrons and charged particles) and can process radiographic information to accomplish such things as image enhancement, tomography and digital radiography. In this review, the authors discuss some of these developments, many of which have not been applied - or widely applied in the nuclear industry

  12. Computed radiography versus mobile direct radiography for bedside chest radiographs: impact of dose on image quality and reader agreement

    NARCIS (Netherlands)

    de Boo, D. W.; Weber, M.; Deurloo, E. E.; Streekstra, G. J.; Freling, N. J.; Dongelmans, D. A.; Schaefer-Prokop, C. M.

    2011-01-01

    To asses the image quality and potential for dose reduction of mobile direct detector (DR) chest radiography as compared with computed radiography (CR) for intensive care unit (ICU) chest radiographs (CXR). Three groups of age-, weight- and disease-matched ICU patients (n=114 patients; 50 CXR per

  13. MO-G-18A-01: Radiation Dose Reducing Strategies in CT, Fluoroscopy and Radiography

    International Nuclear Information System (INIS)

    Mahesh, M; Gingold, E; Jones, A

    2014-01-01

    Advances in medical x-ray imaging have provided significant benefits to patient care. According to NCRP 160, there are more than 400 million x-ray procedures performed annually in the United States alone that contributes to nearly half of all the radiation exposure to the US population. Similar growth trends in medical x-ray imaging are observed worldwide. Apparent increase in number of medical x-ray imaging procedures, new protocols and the associated radiation dose and risk has drawn considerable attention. This has led to a number of technological innovations such as tube current modulation, iterative reconstruction algorithms, dose alerts, dose displays, flat panel digital detectors, high efficient digital detectors, storage phosphor radiography, variable filters, etc. that are enabling users to acquire medical x-ray images at a much lower radiation dose. Along with these, there are number of radiation dose optimization strategies that users can adapt to effectively lower radiation dose in medical x-ray procedures. The main objectives of this SAM course are to provide information and how to implement the various radiation dose optimization strategies in CT, Fluoroscopy and Radiography. Learning Objectives: To update impact of technological advances on dose optimization in medical imaging. To identify radiation optimization strategies in computed tomography. To describe strategies for configuring fluoroscopic equipment that yields optimal images at reasonable radiation dose. To assess ways to configure digital radiography systems and recommend ways to improve image quality at optimal dose

  14. Modelling of scintillator based flat-panel detectors with Monte-Carlo simulations

    International Nuclear Information System (INIS)

    Reims, N; Sukowski, F; Uhlmann, N

    2011-01-01

    Scintillator based flat panel detectors are state of the art in the field of industrial X-ray imaging applications. Choosing the proper system and setup parameters for the vast range of different applications can be a time consuming task, especially when developing new detector systems. Since the system behaviour cannot always be foreseen easily, Monte-Carlo (MC) simulations are keys to gain further knowledge of system components and their behaviour for different imaging conditions. In this work we used two Monte-Carlo based models to examine an indirect converting flat panel detector, specifically the Hamamatsu C9312SK. We focused on the signal generation in the scintillation layer and its influence on the spatial resolution of the whole system. The models differ significantly in their level of complexity. The first model gives a global description of the detector based on different parameters characterizing the spatial resolution. With relatively small effort a simulation model can be developed which equates the real detector regarding signal transfer. The second model allows a more detailed insight of the system. It is based on the well established cascade theory, i.e. describing the detector as a cascade of elemental gain and scattering stages, which represent the built in components and their signal transfer behaviour. In comparison to the first model the influence of single components especially the important light spread behaviour in the scintillator can be analysed in a more differentiated way. Although the implementation of the second model is more time consuming both models have in common that a relatively small amount of system manufacturer parameters are needed. The results of both models were in good agreement with the measured parameters of the real system.

  15. Edge-Spread Functions Expected for Several Changes in a Commercial Flat-Panel System

    International Nuclear Information System (INIS)

    Schach von Wittenau, A E

    2002-01-01

    The Bldg. 239 radiography facility uses a 9 MeV bremsstrahlung linac and a commercially available fiat-panel detector system. Ref. [1] discusses the facility in detail. Ref. [1] furthermore discusses the imaging quality of the fiat-panel system, and identifies several sources of image blur for the system in question. The maim'' contributors to the imaging blur are radiation scattered from the front cover of the detector housing, radiation scattered from the back cover of the detector housing, and radiation scattered from the aluminum plate that supports the amorphous-Si detector within the detector housing. The manufacturer of one such fiat-panel system seems willing to modify one of their products as requested, if such modifications may be made easily. Easy modifications would include making the detector housing thinner, decreasing the sizes of air gaps inside tile detector system, etc. Removing the aluminum support plate is considered to be a difficult modification. This memo reports the results of a set of Monte Carlo simulations that were performed to predict the changes in imaging quality, compared to that of the current system, if the detector is modified as suggested above. In particular, the edge-spread function (ESF) was calculated for each modification. ESFs were calculated for three photon energies: 100 keV, 450 keV, and 3 MeV. The results suggest that thinning and moving tile front and back covers of the detector housing should result in improved image quality for all of the photon energies considered. Interestingly, the results also suggest that removing the aluminum support plate would improve tim imaging performance at 100 keV and 450 keV, but that removing the plate has no additional benefit for imaging with 3 MeV photons

  16. Tracking brachytherapy sources using emission imaging with one flat panel detector

    International Nuclear Information System (INIS)

    Song Haijun; Bowsher, James; Das, Shiva; Yin Fangfang

    2009-01-01

    This work proposes to use the radiation from brachytherapy sources to track their dwell positions in three-dimensional (3D) space. The prototype device uses a single flat panel detector and a BB tray. The BBs are arranged in a defined pattern. The shadow of the BBs on the flat panel is analyzed to derive the 3D coordinates of the illumination source, i.e., the dwell position of the brachytherapy source. A kilovoltage x-ray source located 3.3 m away was used to align the center BB with the center pixel on the flat panel detector. For a test plan of 11 dwell positions, with an Ir-192 high dose rate unit, one projection was taken for each dwell point, and locations of the BB shadows were manually identified on the projection images. The 3D coordinates for the 11 dwell positions were reconstructed based on two BBs. The distances between dwell points were compared with the expected values. The average difference was 0.07 cm with a standard deviation of 0.15 cm. With automated BB shadow recognition in the future, this technique possesses the potential of tracking the 3D trajectory and the dwell times of a brachytherapy source in real time, enabling real time source position verification.

  17. Radiation dose reduction using a CdZnTe-based computed tomography system: Comparison to flat-panel detectors

    Energy Technology Data Exchange (ETDEWEB)

    Le, Huy Q.; Ducote, Justin L.; Molloi, Sabee [Department of Radiological Sciences, University of California, Irvine, California 92697 (United States)

    2010-03-15

    Purpose: Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficult. Breast computed tomography using flat-panel detectors has been developed to address this limitation by producing three-dimensional data while at the same time providing more comfort to the patients by eliminating breast compression. Flat panels are charge integrating detectors and therefore lack energy resolution capability. Recent advances in solid state semiconductor x-ray detector materials and associated electronics allow the investigation of x-ray imaging systems that use a photon counting and energy discriminating detector, which is the subject of this article. Methods: A small field-of-view computed tomography (CT) system that uses CdZnTe (CZT) photon counting detector was compared to one that uses a flat-panel detector for different imaging tasks in breast imaging. The benefits afforded by the CZT detector in the energy weighting modes were investigated. Two types of energy weighting methods were studied: Projection based and image based. Simulation and phantom studies were performed with a 2.5 cm polymethyl methacrylate (PMMA) cylinder filled with iodine and calcium contrast objects. Simulation was also performed on a 10 cm breast specimen. Results: The contrast-to-noise ratio improvements as compared to flat-panel detectors were 1.30 and 1.28 (projection based) and 1.35 and 1.25 (image based) for iodine over PMMA and hydroxylapatite over PMMA, respectively. Corresponding simulation values were 1.81 and 1.48 (projection based) and 1.85 and 1.48 (image based). Dose reductions using the CZT detector were 52.05% and 49.45% for iodine and hydroxyapatite imaging, respectively. Image-based weighting was also found to have the least beam

  18. Radiation dose reduction using a CdZnTe-based computed tomography system: Comparison to flat-panel detectors

    International Nuclear Information System (INIS)

    Le, Huy Q.; Ducote, Justin L.; Molloi, Sabee

    2010-01-01

    Purpose: Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficult. Breast computed tomography using flat-panel detectors has been developed to address this limitation by producing three-dimensional data while at the same time providing more comfort to the patients by eliminating breast compression. Flat panels are charge integrating detectors and therefore lack energy resolution capability. Recent advances in solid state semiconductor x-ray detector materials and associated electronics allow the investigation of x-ray imaging systems that use a photon counting and energy discriminating detector, which is the subject of this article. Methods: A small field-of-view computed tomography (CT) system that uses CdZnTe (CZT) photon counting detector was compared to one that uses a flat-panel detector for different imaging tasks in breast imaging. The benefits afforded by the CZT detector in the energy weighting modes were investigated. Two types of energy weighting methods were studied: Projection based and image based. Simulation and phantom studies were performed with a 2.5 cm polymethyl methacrylate (PMMA) cylinder filled with iodine and calcium contrast objects. Simulation was also performed on a 10 cm breast specimen. Results: The contrast-to-noise ratio improvements as compared to flat-panel detectors were 1.30 and 1.28 (projection based) and 1.35 and 1.25 (image based) for iodine over PMMA and hydroxylapatite over PMMA, respectively. Corresponding simulation values were 1.81 and 1.48 (projection based) and 1.85 and 1.48 (image based). Dose reductions using the CZT detector were 52.05% and 49.45% for iodine and hydroxyapatite imaging, respectively. Image-based weighting was also found to have the least beam

  19. Using a Borated Panel to Form a Dual Neutron-Gamma Detector

    Energy Technology Data Exchange (ETDEWEB)

    Scott Wilde; Raymond Keegan

    2008-06-20

    A borated polyethylene plane placed between a neutron source and a gamma spectrometer is used to form a dual neutron-gamma detection system. The polyethylene thermalizes the source neutrons so that they are captured by {sup 10}B to produce a flux of 478 keV gamma-rays that radiate from the plane. This results in a buildup of count rate in the detector over that from a disk of the same diameter as the detector crystal (same thickness as the panel). Radiation portal systems are a potential application of this technique.

  20. Pulsed X-ray radiography of a gas jet target for laser-matter interaction experiments with the use of a CCD detector

    International Nuclear Information System (INIS)

    Rakowski, R.; Bartnik, A.; Fiedorowicz, H.; Jarocki, R.; Kostecki, J.; MikoIajczyk, J.; Szczurek, A.; Szczurek, M.; Foeldes, I.B.; Toth, Zs.

    2005-01-01

    Characterization of gas jet targets has been carried out using pulsed X-ray radiography. A laser-plasma X-ray source was applied for backlighting of the targets to obtain X-ray shadowgraphs registered with a CCD detector. From the shadowgraphs, characteristics of the targets were determined

  1. Film replacement by digital x-ray detectors - the correct procedure and equipment

    International Nuclear Information System (INIS)

    Ewert, U.; Zscherpel, U.; Bavendiek, K.

    2004-01-01

    New digital detectors were developed for medical applications, which have the potential to substitute the X-ray film and revolutionise the radiological technique. Digital Detector Arrays (DDA: Flat Panel Detectors, Line Detectors) and Imaging Plates (Computed Radiography) allow a fast detection of radiographic images in a shorter time and with higher dynamic than film applications. Companies report about a reduction of exposure time down to 5 - 25% in comparison to NDT film exposures. This provides together with the reduction of consumables economical (and also ecological) benefits and short amortisation periods. But this does not always provide the same image quality as NDT film. The requirements of the European and USA standards for film radiography are analysed to derive correct requirements for the digital image quality and procedures for prediction and measurement of image quality. Basically the USA standards seem to be more tolerant for these new innovative technologies. New standard proposals use signal/noise ratio and unsharpness as dominant parameters for image quality. Specialised measurement procedures are described. The properties of the new detectors can be controlled by electronics and exposure conditions. New names appear in literature like 'direct radiography' and 'film replacement techniques'. The basic advantage of the new digital techniques is the possibility to use numeric procedures for image interpretation. Industrial radiology can be optimised for crack detection as well as for analysis of flaw depth and shape measurement. Automated flaw detection, measurement of part dimensions and detection of completeness are used for serial part inspection devices. Parallel to the development of DDA's, an extraordinary increase of Computed Tomography (CT) applications can be observed. (author)

  2. Dynamic neutron radiography of a combustion engine

    International Nuclear Information System (INIS)

    Brunner, J.; Hillenbach, A.; Schillinger, B.

    2004-01-01

    Dynamic neutron radiography is a non-destructive testing method, which made big steps in the last years. Depending on the neutron flux, the object and the detector a time resolution down to 50 ms is possible. In the case of repetitive processes the object can be synchronized with the detector and better statistics in the image can be obtained by adding radiographies of the same phase. By delaying the trigger signal a radiography movie can be composed with a time resolution down to 100 μs. A combustion engine is an ideal sample for the explained technique, because the motor block of metal is relatively easy to penetrate, while oil and fuel attenuate the thermal neutron beam much stronger. Various experiments were performed at ILL and PSI. Soon the tomography station ANTARES at FRM-II will be ready for measurements. (author)

  3. Medical radiography with fast neutrons

    International Nuclear Information System (INIS)

    Duehmke, E.

    1980-01-01

    Neutron radiography is important in medicine for two reasons. On the one hand, macroradiographical findings are different from X-ray findings, i.e. new information may be gained on the morphology of humans and animals. On the other hand, there is a direct practical application in the radiotherapy of malignant tumours if one considers the assessment of the growth of malignant processes. Fast neutrons are required for neutron radiographies of biological objects with a diameter of more than 2 cm. In addition sensitive, two-dimensional detectors must be used which are selective for fast neutrons. The book describes the optimisation and sensitisation of a detector using the example of cellulose nitrate foil for fast reactor neutrons. Images of human spinal chords with tumours proved by pathological and anatomical examinations give a better picture of the dimensions of the tumour than comparative X-ray pictures. For examinations of living patients, neutron radiography should be applied only in those tumour-bearing parts of the bodies in which radiation treatment is required for therapeutical purposes anyway. (orig./MG) [de

  4. A compact high resolution flat panel PET detector based on the new 4-side buttable MPPC for biomedical applications.

    Science.gov (United States)

    Wang, Qiang; Wen, Jie; Ravindranath, Bosky; O'Sullivan, Andrew W; Catherall, David; Li, Ke; Wei, Shouyi; Komarov, Sergey; Tai, Yuan-Chuan

    2015-09-11

    Compact high-resolution panel detectors using virtual pinhole (VP) PET geometry can be inserted into existing clinical or pre-clinical PET systems to improve regional spatial resolution and sensitivity. Here we describe a compact panel PET detector built using the new Though Silicon Via (TSV) multi-pixel photon counters (MPPC) detector. This insert provides high spatial resolution and good timing performance for multiple bio-medical applications. Because the TSV MPPC design eliminates wire bonding and has a package dimension which is very close to the MPPC's active area, it is 4-side buttable. The custom designed MPPC array (based on Hamamatsu S12641-PA-50(x)) used in the prototype is composed of 4 × 4 TSV-MPPC cells with a 4.46 mm pitch in both directions. The detector module has 16 × 16 lutetium yttrium oxyorthosilicate (LYSO) crystal array, with each crystal measuring 0.92 × 0.92 × 3 mm 3 with 1.0 mm pitch. The outer diameter of the detector block is 16.8 × 16.8 mm 2 . Thirty-two such blocks will be arranged in a 4 × 8 array with 1 mm gaps to form a panel detector with detection area around 7 cm × 14 cm in the full-size detector. The flood histogram acquired with Ge-68 source showed excellent crystal separation capability with all 256 crystals clearly resolved. The detector module's mean, standard deviation, minimum (best) and maximum (worst) energy resolution were 10.19%, +/-0.68%, 8.36% and 13.45% FWHM, respectively. The measured coincidence time resolution between the block detector and a fast reference detector (around 200 ps single photon timing resolution) was 0.95 ns. When tested with Siemens Cardinal electronics the performance of the detector blocks remain consistent. These results demonstrate that the TSV-MPPC is a promising photon sensor for use in a flat panel PET insert composed of many high resolution compact detector modules.

  5. Performance Study of an aSi Flat Panel Detector for Fast Neutron Imaging of Nuclear Waste

    Energy Technology Data Exchange (ETDEWEB)

    Schumann, M.; Mauerhofer, E. [Institute of Energy and Climate Research - Nuclear Waste Management and Reactor Safety, Forschungszentrum Juelich GmbH, 52425 Juelich (Germany); Engels, R.; Kemmerling, G. [Central Institute for Engineering, Electronics and Analytics - Electronic Systems, Forschungszentrum Juelich GmbH, 52425 Juelich (Germany); Frank, M. [MATHCCES - Department of Mathematics, RWTH Aachen University, 52062 Aachen (Germany); Havenith, A.; Kettler, J.; Klapdor-Kleingrothaus, T. [Institute of Nuclear Engineering and Technology Transfer, RWTH Aachen University, 52062 Aachen (Germany); Schitthelm, O. [Corporate Technology, Siemens AG, 91058 Erlangen (Germany)

    2015-07-01

    Radioactive waste must be characterized to check its conformance for intermediate storage and final disposal according to national regulations. For the determination of radio-toxic and chemo-toxic contents of radioactive waste packages non-destructive analytical techniques are preferentially used. Fast neutron imaging is a promising technique to assay large and dense items providing, in complementarity to photon imaging, additional information on the presence of structures in radioactive waste packages. Therefore the feasibility of a compact Neutron Imaging System for Radioactive waste Analysis (NISRA) using 14 MeV neutrons is studied in a cooperation framework of Forschungszentrum Juelich GmbH, RWTH Aachen University and Siemens AG. However due to the low neutron emission of neutron generators in comparison to research reactors the challenging task resides in the development of an imaging detector with a high efficiency, a low sensitivity to gamma radiation and a resolution sufficient for the purpose. The setup is composed of a commercial D-T neutron generator (Genie16GT, Sodern) with a surrounding shielding made of polyethylene, which acts as a collimator and an amorphous silicon flat panel detector (aSi, 40 x 40 cm{sup 2}, XRD-1642, Perkin Elmer). Neutron detection is achieved using a general propose plastic scintillator (EJ-260, Eljen Technology) linked to the detector. The thermal noise of the photodiodes is reduced by employing an entrance window made of aluminium. Optimal gain and integration time for data acquisition are set by measuring the response of the detector to the radiation of a 500 MBq {sup 241}Am-source. Detector performance was studied by recording neutron radiography images of materials with various, but well known, chemical compositions, densities and dimensions (Al, C, Fe, Pb, W, concrete, polyethylene, 5 x 8 x 10 cm{sup 3}). To simulate gamma-ray emitting waste radiographs in presence of a gamma-ray sources ({sup 60}Co, {sup 137}Cs, {sup 241

  6. Figures of merit for detectors in digital radiography. II. Finite number of secondaries and structured backgrounds

    International Nuclear Information System (INIS)

    Pineda, Angel R.; Barrett, Harrison H.

    2004-01-01

    The current paradigm for evaluating detectors in digital radiography relies on Fourier methods. Fourier methods rely on a shift-invariant and statistically stationary description of the imaging system. The theoretical justification for the use of Fourier methods is based on a uniform background fluence and an infinite detector. In practice, the background fluence is not uniform and detector size is finite. We study the effect of stochastic blurring and structured backgrounds on the correlation between Fourier-based figures of merit and Hotelling detectability. A stochastic model of the blurring leads to behavior similar to what is observed by adding electronic noise to the deterministic blurring model. Background structure does away with the shift invariance. Anatomical variation makes the covariance matrix of the data less amenable to Fourier methods by introducing long-range correlations. It is desirable to have figures of merit that can account for all the sources of variation, some of which are not stationary. For such cases, we show that the commonly used figures of merit based on the discrete Fourier transform can provide an inaccurate estimate of Hotelling detectability

  7. Muon radiography technology for detecting high-Z materials

    International Nuclear Information System (INIS)

    Ma Lingling; Wang Wenxin; Zhou Jianrong; Sun Shaohua; Liu Zuoye; Li Lu; Du Hongchuan; Zhang Xiaodong; Hu Bitao

    2010-01-01

    This paper studies the possibility of using the scattering of cosmic muons to identify threatening high-Z materials. Various scenarios of threat material detection are simulated with the Geant4 toolkit. PoCA (Point of Closest Approach) algorithm reconstructing muon track gives 3D radiography images of the target material. Z-discrimination capability, effects of the placement of high-Z materials, shielding materials inside the cargo, and spatial resolution of position sensitive detector for muon radiography are carefully studied. Our results show that a detector position resolution of 50 μm is good enough for shielded materials detection. (authors)

  8. Resolution requirements for monitor viewing of digital flat-panel detector radiographs: a contrast detail analysis

    International Nuclear Information System (INIS)

    Peer, Siegfried; Giacomuzzi, Salvatore M.; Peer, Regina; Gassner, Eva; Steingruber, Iris; Jaschke, Werner

    2003-01-01

    With the introduction of digital flat-panel detector systems into clinical practice, the still unresolved question of resolution requirements for picture archiving communication system (PACS) workstation monitors has gained new momentum. This contrast detail analysis was thus performed to define the differences in observer performance in the detection of small low-contrast objects on clinical 1K and 2K monitor workstations. Images of the CDRAD 2.0 phantom were acquired at varying exposures on an indirect-type digital flat-panel detector. Three observers evaluated a total of 15 images each with respect to the threshold contrast for each detail size. The numbers of correctly identified objects were determined for all image subsets. No significant difference in the correct detection ratio was detected among the observers; however, the difference between the two types of workstations (1K vs 2K monitors) despite less than 3% was significant at a 95% confidence level. Slight but statistically significant differences exist in the detection of low-contrast nodular details visualized on 1K- and 2K-monitor workstations. Further work is needed to see if this result holds true also for comparison of clinical flat-panel detector images and may, for example, exert an influence on the diagnostic accuracy of chest X-ray readings. (orig.)

  9. X-ray radiation detectors of 'scintillator-photoreceiving device type' for industrial digital radiography with improved spatial resolution

    International Nuclear Information System (INIS)

    Ryzhykov, V.D.; Lysetska, O.K.; Opolonin, O.D.; Kozin, D.N.

    2003-01-01

    Main types of photo receivers used in X-ray digital radiography systems are luminescent screens that transfer the optical image onto charge collection instruments, which require cooling, and semiconductor silicon detectors, which limit the contrast sensitivity. We have developed and produced X-ray radiation detectors of 'scintillator-photoreceiving device' (S-PRD) type, which are integrally located on the inverse side of the photodiode (PD). The receiving-converting circuit (RCC) is designed for data conversion into digital form and their input into PC. Software is provided for RCC control and image visualization. Main advantages of these detectors are high industrial resolution (3-5 line pairs per mm), detecting activity up to 20 μm, controlled sensitivity, low weight and small size, imaging low (0.1-0.3 mrad) object dose in real time. In this work, main characteristics of 32-, 64- and 1024-channel detectors of S-PRD type were studied and compared for X-ray sensitivity with S-PD detectors. Images of the tested objects have been obtained. Recommendations are given on the use of different scintillation materials, depending upon the purpose of a digital radiographic system. The detectors operate in a broad energy range of ionizing radiation, hence the size of the controlled object is not limited. The system is sufficiently powerful to ensure frontal (through two walls) observation of pipelines with wall thickness up to 10 cm

  10. First results with a microcavity plasma panel detector

    Energy Technology Data Exchange (ETDEWEB)

    Ball, R. [University of Michigan, Department of Physics, Ann Arbor, MI 48109 (United States); Ben-Moshe, M.; Benhammou, Y.; Bensimon, R. [Tel Aviv University, School of Physics and Astronomy, Tel Aviv (Israel); Chapman, J.W. [University of Michigan, Department of Physics, Ann Arbor, MI 48109 (United States); Davies, M.; Etzion, E. [Tel Aviv University, School of Physics and Astronomy, Tel Aviv (Israel); Ferretti, C., E-mail: claudiof@umich.edu [University of Michigan, Department of Physics, Ann Arbor, MI 48109 (United States); Friedman, P.S. [Integrated Sensors, LLC, Ottawa Hills, OH 43606 (United States); Levin, D.S. [University of Michigan, Department of Physics, Ann Arbor, MI 48109 (United States); Silver, Y. [Tel Aviv University, School of Physics and Astronomy, Tel Aviv (Israel); Varner, R.L. [Oak Ridge National Laboratory, Physics Division, Oak Ridge, TN 737831 (United States); Weaverdyck, C.; Zhou, B. [University of Michigan, Department of Physics, Ann Arbor, MI 48109 (United States)

    2015-06-01

    A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1×1×2 mm cells. It has shown very clean signals of 0.6–2.5 V amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with β particles from a radioactive source, a maximum pixel efficiency greater than 95% is calculated, for operation of the detector over a 100 V wide span of high voltages (HV). Over this same HV range, the background rate per pixel was measured to be 3–4 orders of magnitude lower than the rate with which the cell was illuminated by the β source. Pixel-to-pixel count rate uniformity is within 3% and stable within 3% for many days. The time resolution is 2.4 ns, and a very low cell-to-cell crosstalk has been measured between cells separated by 2 mm.

  11. Clinical evaluation of digital angiographic system equipped with the Safire' flat-panel detector of a direct conversion type

    International Nuclear Information System (INIS)

    Miura, Yoshiaki; Miura, Yusuke; Goto, Keiichi

    2003-01-01

    This report presents a report on clinical evaluation of our newly developed flat-panel X-ray detector of a direct conversion type, designed to provide images of a resolution higher than, or at least equal to, that ensured by X-ray photographic films, in clinical digital X-ray cinematography. This new detector was named 'Safire' the acronym of 'Shimadzu advanced flat imaging receptor', emphasizing its high technological level, such as the capability to ensure high quality of images. The clinical evaluation of Shimadzu DIGITEX Premier digital angiography system, equipped with this new flat-panel X-ray detector of a direct conversion type, has been started in March, 2003, at the Kokura Memorial Hospital in Kyushu, Japan. (author)

  12. Neutron radiography

    International Nuclear Information System (INIS)

    Alaa eldin, M.T.

    2011-01-01

    The digital processing of the neutron radiography images gives the possibility for data quantification. In this case an exact relation between the measured neutron attenuation and the real macroscopic attenuation coefficient for every point of the sample is required. The assumption that the attenuation of the neutron beam through the sample is exponential is valid only in an ideal case where a monochromatic beam, non scattering sample and non background contribution are assumed. In the real case these conditions are not fulfilled and in dependence on the sample material we have more or less deviation from the exponential attenuation law. Because of the high scattering cross-sections of hydrogen (σs=80.26 barn) for thermal neutrons, the problem with the scattered neutrons at quantitative radiography investigations of hydrogenous materials (as PE, Oil, H 2 O, etc) is not trivial. For these strong scattering materials the neutron beam attenuation is no longer exponential and a dependence of the macroscopic attenuation coefficient on the material thickness and on the distance between the sample and the detector appears. When quantitative radiography (2 D) or tomography investigations (3 D) are performed, some image correction procedures for a description of the scattering effect are required. This thesis presents a method that can be used to enhance the neutron radiography image for objects with high scattering materials like hydrogen, carbon and other light materials. This method uses the Monte Carlo code, MCNP5, to simulate the neutron radiography process and get the flux distribution for each pixel of the image and determine the scattered neutrons distribution that causes the image blur and then subtract it from the initial image to improve its quality.

  13. A preliminary design of mechanical device on industrial digital radiography equipment design

    International Nuclear Information System (INIS)

    Nur Khasan; Samuel Praptoyo

    2015-01-01

    A preliminary design of mechanical device on industrial digital radiography equipment has been done. this design is intended as a basis for the manufacture of complete facilities for the realization a prototype on industrial digital radiography equipment. the design and construction were carried out by paying attention to the general configuration of the basic design in which its mechanical design has several components with specific dimensions and heavy mass. this design consist of a main frame holder, flat panel detector support and hydraulic hand stacker for mounting the x-ray machine. this mechanical device design will then be fabricated to facilitate and assist work of digital radiographic retrieval. computer application programs sketch-up is used to draw this design and the analysis stress of autodesk inventor to analysis the strength construction design. the results of this design are the configuration drawing, sketch drawings of construction and the safety factor of construction design with a minimum value of 2.39 as well as a maximum value of 15 when to be simulated by the load 500 Kg which is 4 times of total workload. (author)

  14. Evaluation the image obtained from X-ray flat-panel detectors utilizing a polycrystalline CdZnTe film as the conversion layer

    International Nuclear Information System (INIS)

    Tokuda, S.; Kishihara, H.; Kaino, M.; Sato, T.

    2006-01-01

    We can expect that fluoroscopic images with a high sensitivity and excellent detective efficiency can be obtained by using a semiconductor with a small W factor for the conversion layer of X-ray flat-panel detectors, which have experienced a rapid gain inpopularity for medical and non-destructive industrial inspection uses in recent years. We believe that polycrystalline CdZnTe film formed by the closed spaced sublimation (CSS) method is a promising conversion material for next-generation high efficiency X-ray flat-panel detectors, and have previously reported the results of feasibility studies. In this paper, we present an overview of X-ray flat-panel detectors and the features of CdZnTe film, then we describe the CSS method of deposition and evaluation of the physical characteristics of CdZnTe film, and finally we present the results of our fabrication and testing of proto-type detectors utilizing CdZnTe film. (author)

  15. Comparison study on CNR and SNR of thoracic spine lateral radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Won [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Min, Jung Whan; Lyu, Kwang Yeul [Dept. of Radiology, Shingu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Science, College of Health Science, Korea University, Seoul (Korea, Republic of); Jeong, Hei Woun [Dept. of Radiological Science, Beakseok Culture University, Cheonan (Korea, Republic of); Lee, Joo Ah [Dept. of Oncology, Catholic University of Korea Incheon St.Mary,s Hospital, Incheon (Korea, Republic of); Jung, Jae Hong [Dept. of Oncology, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Sung, Dong Chan [Dept. of Radiology, Dong Guk University Medical Center, Seoul (Korea, Republic of); Park, Soon Cheol [Dept. of Radiology, Kang Dong Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2013-12-15

    This study was proven for the T-spine breathing technique in lateral projection, using computer radiography (CR), charge coupled device (CCD), indirect digital radiography (IDR) and direct digital radiography (DDR). All images were evaluated and compared with CNR and SNR measured with the mean pixels and the standard deviation as setting ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk using Image J. In experiment results of 4 type detectors, T-spine breathing technique was indicated as excellent in ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk. As T-spine breathing technique indicated excellent images compared to the existing T-spine lateral radiography, this method would be useful for elderly patients who have difficulty in deep exhalation. This study was indicated the application possibility of T-spine breathing technique by presenting contrast to noise ratio (CNR) and signal to noise ratio (SNR) with quantitative value in 4 type detectors.

  16. Dynamic defectoscopy with flat panel and CdTe Timepix X-ray detectors combined with an optical camera

    Czech Academy of Sciences Publication Activity Database

    Vavřík, Daniel; Fauler, A.; Fiederle, M.; Jandejsek, Ivan; Jakůbek, J.; Tureček, D.; Zwerger, A.

    2013-01-01

    Roč. 8, April (2013), C04009 ISSN 1748-0221. [International Workshop on Radiation Imaging Detectors /14./. Figueira da Foz, Coimbra, 01.07.2012-05.07.2012] R&D Projects: GA ČR(CZ) GA103/09/2101 Institutional support: RVO:68378297 Keywords : X-ray digital radiography * fracture mechanics * crack path * X-ray defectoscopy Subject RIV: JM - Building Engineering Impact factor: 1.526, year: 2013 http://iopscience.iop.org/1748-0221/8/04/C04009/

  17. Digital radiography

    International Nuclear Information System (INIS)

    Brody, W.R.

    1984-01-01

    Digital Radiography begins with an orderly introduction to the fundamental concepts of digital imaging. The entire X-ray digital imagining system is described, from an overall characterization of image quality to specific components required for a digital radiographic system. Because subtraction is central to digital radiographic systems, the author details the use of various subtraction methods for image enhancement. Complex concepts are illustrated with numerous examples and presented in terms that can readily be understood by physicians without an advanced mathematics background. The second part of the book discusses implementations and applications of digital imagining systems based on area and scanned detector technologies. This section includes thorough coverage of digital fluoroscopy, scanned projection radiography, and film-based digital imaging systems, and features a state-of-the-art synopsis of the applications of digital subtraction angiography. The book concludes with a timely assessment of anticipated technological advances

  18. Projection radiography and tomography

    International Nuclear Information System (INIS)

    Tobias, C.A.; Fabrikant, J.I.; Benton, E.V.; Holley, W.R.

    1980-01-01

    Our program on heavy-ion radiography began soon after heavy ions were accelerated to high energies. Heavy ions are capable of very high electron density discrimination combined with good radial image resolution and low dose. Since heavy-ion beams produce many secondries, plastic nuclear detectors have an advantage for recording heavy-ion images. Projection imaging is now a practical technique that can resolve density differences between normal tissue and tumor tissue in some cases in which X rays could not make a distinction. Initial attempts at heavy-ion tomography also indicate potential for high resolution in this field. The physical basis for heavy-ion radiography and tomographic reconstruction studies are discussed in detail

  19. Neutron-induced alpha radiography; Radiografia com particulas alfa induzida por neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Marco Antonio Stanojev

    2008-07-01

    A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the {alpha} - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70 deg C respectively. For such conditions samples having 10 {mu}m in thickness can be inspected with a spatial resolution of 32 {mu}m. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to {beta}, {gamma}, X-ray and visible light. (author)

  20. Improvements in or relating to radiography

    International Nuclear Information System (INIS)

    Logan, A.B.; Marsh, R.G.; Fleming, I.A.

    1980-01-01

    Tomographic apparatus for use in biomedical radiography is described in detail. The radiation source and detectors are capable of rotating around the axis of the body under investigation to measure the absorption coefficients of a particular slice. Additionally, the detectors and source are capable of lateral motion across the body slice. Detailed suggestions of the number and optimum angular size of the detectors are given as well as the various angular steps of rotation of the source and detectors. Rotations in excess of 180 0 may be performed since the direction of travel of the X-radiation is not significant for constructing the absorption picture. (UK)

  1. Calibration model of a dual gain flat panel detector for 2D and 3D x-ray imaging

    International Nuclear Information System (INIS)

    Schmidgunst, C.; Ritter, D.; Lang, E.

    2007-01-01

    The continuing research and further development in flat panel detector technology have led to its integration into more and more medical x-ray systems for two-dimensional (2D) and three-dimensional (3D) imaging, such as fixed or mobile C arms. Besides the obvious advantages of flat panel detectors, like the slim design and the resulting optimum accessibility to the patient, their success is primarily a product of the image quality that can be achieved. The benefits in the physical and performance-related features as opposed to conventional image intensifier systems (e.g., distortion-free reproduction of imaging information or almost linear signal response over a large dynamic range) can be fully exploited, however, only if the raw detector images are correctly calibrated and postprocessed. Previous procedures for processing raw data contain idealizations that, in the real world, lead to artifacts or losses in image quality. Thus, for example, temperature dependencies or changes in beam geometry, as can occur with mobile C arm systems, have not been taken into account up to this time. Additionally, adverse characteristics such as image lag or aging effects have to be compensated to attain the best possible image quality. In this article a procedure is presented that takes into account the important dependencies of the individual pixel sensitivity of flat panel detectors used in 2D or 3D imaging and simultaneously minimizes the work required for an extensive recalibration. It is suitable for conventional detectors with only one gain mode as well as for the detectors specially developed for 3D imaging with dual gain read-out technology

  2. Clinical evaluation of digital angiographic system equipped with the Safire' flat-panel detector of a direct conversion type

    Energy Technology Data Exchange (ETDEWEB)

    Miura, Yoshiaki; Miura, Yusuke; Goto, Keiichi [Shimadzu Corporation, Medical Systems Division, Research and Development, Kyoto (JP)] [and others

    2003-06-01

    This report presents a report on clinical evaluation of our newly developed flat-panel X-ray detector of a direct conversion type, designed to provide images of a resolution higher than, or at least equal to, that ensured by X-ray photographic films, in clinical digital X-ray cinematography. This new detector was named 'Safire' the acronym of 'Shimadzu advanced flat imaging receptor', emphasizing its high technological level, such as the capability to ensure high quality of images. The clinical evaluation of Shimadzu DIGITEX Premier digital angiography system, equipped with this new flat-panel X-ray detector of a direct conversion type, has been started in March, 2003, at the Kokura Memorial Hospital in Kyushu, Japan. (author)

  3. Alpha particle radiography and the track plastic detector CR-39

    International Nuclear Information System (INIS)

    Souza, Bismarck Amilar de.

    1991-05-01

    This work develops the radiographic technique using charged particle beams. This technique complements the X-ray conventional radiography, and presents some advantages in certain cases. The material used as nuclear plastic detector was CR-39, manufactured by Pershre Mould. England, of 250 and 1000 μm nominal thicknesses. The irradiations were made with 7 MeV/Nucleon alpha particles beams, accelerated in the CV-28 Cyclotron of Instituto de Engenharia Nuclear/CNEN - Rio de Janeiro. The etch conditions used were a Na OH 6,25 N solution at 70 0 C, varying the etch time, so that the best etch time was found to be six hours. The calibration curve is presented, which permits images interpretation, showed in terms of light transmittance (obtained using a micro densitometer), and in terms of energy losses suffered by alpha particles in several aluminum degradating thicknesses. This curve was checked by the use of other degradating materials: Mylar, Makrofol, and CR-39 itself. The influence of alpha particle beam FWHM widening on images quality, when it crosses several degradating materials, is also presented. Radiographs of some specimen are presented, including some images obtained varying some irradiation and etch parameters. (author). 62 refs., 22 figs., 19 tabs

  4. Startup data for the Stationary Neutron Radiography Reactor (SNRS)

    International Nuclear Information System (INIS)

    Heidel, C.C.; Richards, W.J.

    1990-01-01

    Moisture and corrosion in the F-lll aluminum honeycomb structure is a significant maintenance problem for these 1960 vintage aircraft. Corrosion and moisture are not readily detectable with conventional nondestructive testing techniques such as X-ray. However, by using neutron radiography, high quality images of the corrosion and moisture within the panels can be obtained. The SNRS-1 TRIGA was developed to provide the high intensity neutron source needed to support systems that enable neutron radiography to be performed on these aircraft parts

  5. Employment of the polycarbonates Makrofol-DE and CR-39 for neutron radiography

    International Nuclear Information System (INIS)

    Pereira, Marco Antonio Stanojev

    2000-01-01

    The track-etch method was employed for Neutron Radiography purposes. The solid state nuclear track detectors Makrofol-DE and CR-39 together with a natural boron converter screen have been used as imaging systems. In order to determine their radiographic characteristics, the imaging systems were irradiated up to neutron exposures around 6x10 10 /cm 2 in a radiography facility installed at the IEA-R1 Nuclear Research Reactor and the detectors developed between 2 and 65 minutes. The main goal of this work was determine the radiography conditions for which the best contrast and resolution are obtained at the image. These conditions are: - Makrofol-DE: neutron exposure between 2x10 9 n/cm 2 and 2x10 10 n/cm 2 and developing time 6 minutes; CR-39: neutron exposure between 3x10 9 n/cm 2 and 2x10 10 n/cm 2 and developing time 25 minutes. The present results were compared with those ones determined to other track detectors, and discussed according to the theory of the image formation in solid state nuclear track detectors based on the optical properties of a single track. (author)

  6. Absorbed doses for patients undergoing panoramic radiography, cephalometric radiography and CBCT

    Directory of Open Access Journals (Sweden)

    Małgorzata Wrzesień

    2017-10-01

    Full Text Available Objectives: Contemporary dental radiology offers a wide spectrum of imaging methods but it also contributes to an increase in the participation of dental radiological diagnosis in the patient’s exposure to ionizing radiation. The aim of this study is to determine the absorbed doses of the brain, spinal column, thyroid and eye lens for patients during panoramic radiography, cephalometric radiography and cone beam computed tomography (CBCT. Material and Methods: The thermoluminescent dosimetry and anthropomorphic phantom was used for measuring the doses. The 15 panoramic, 4 cephalometric and 4 CBCT exposures were performed by placing high-sensitivity thermoluminescent detectors (TLD in 18 anatomical points of the phantom. Results: The maximum absorbed dose recorded during performed measurements corresponds to the point representing the brainstem and it is 10 mGy. The dose value recorded by the TLD placed in the thyroid during CBCT imaging in relation to the panoramic radiography differs by a factor of 13.5. Conclusions: Cone beam computed tomography, in comparison with panoramic or cephalometric imaging technique, provides higher radiation doses to the patients. Int J Occup Med Environ Health 2017;30(5:705–713

  7. Effect of comfort pads and incubator design on neonatal radiography

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xia; Baad, Michael; Reiser, Ingrid; Feinstein, Kate A.; Lu, Zhengfeng [University of Chicago Medicine, Department of Radiology, Chicago, IL (United States)

    2016-01-15

    There has been increasing interest in patient dose reduction in neonatal intensive care units. Removing comfort pads for radiography has been identified as a potential means to decrease patient dose. To assess the effect of comfort pads and support trays on detector entrance exposure (DEE) and image quality for neonatal radiography, and its implication for patient dose. Comfort pads and support trays from three incubator and warmer systems were examined. The attenuation of the primary beam by these structures was measured using a narrow beam geometry. Their effect on DEE and image quality was then assessed using typical neonatal chest radiography techniques with three configurations: (1) both the comfort pad and support included in the beam, (2) only the support tray included and (3) both the comfort pad and support tray removed. Comfort pads and support trays were found to attenuate the primary beam by 6-15%. Eliminating these structures from the X-ray beam's path was found to increase the detector entrance exposure by 28-36% and increase contrast-to-noise ratio by more than 21%, suggesting room for patient dose reduction when the same image quality is maintained. Comfort pads and tray support devices can have a considerable effect on DEE and image quality, with large variations among different incubator designs. Positioning the image detector directly underneath neonatal patients for radiography is a potential means for patient dose reduction. However, such benefit should be weighed against the risks of moving the patient. (orig.)

  8. Effect of comfort pads and incubator design on neonatal radiography

    International Nuclear Information System (INIS)

    Jiang, Xia; Baad, Michael; Reiser, Ingrid; Feinstein, Kate A.; Lu, Zhengfeng

    2016-01-01

    There has been increasing interest in patient dose reduction in neonatal intensive care units. Removing comfort pads for radiography has been identified as a potential means to decrease patient dose. To assess the effect of comfort pads and support trays on detector entrance exposure (DEE) and image quality for neonatal radiography, and its implication for patient dose. Comfort pads and support trays from three incubator and warmer systems were examined. The attenuation of the primary beam by these structures was measured using a narrow beam geometry. Their effect on DEE and image quality was then assessed using typical neonatal chest radiography techniques with three configurations: (1) both the comfort pad and support included in the beam, (2) only the support tray included and (3) both the comfort pad and support tray removed. Comfort pads and support trays were found to attenuate the primary beam by 6-15%. Eliminating these structures from the X-ray beam's path was found to increase the detector entrance exposure by 28-36% and increase contrast-to-noise ratio by more than 21%, suggesting room for patient dose reduction when the same image quality is maintained. Comfort pads and tray support devices can have a considerable effect on DEE and image quality, with large variations among different incubator designs. Positioning the image detector directly underneath neonatal patients for radiography is a potential means for patient dose reduction. However, such benefit should be weighed against the risks of moving the patient. (orig.)

  9. Structural analysis of jewelry from the Moche tomb of the `lady of Cao' by X-ray digital radiography

    Science.gov (United States)

    Azeredo, S. R.; Cesareo, R.; Franco, R.; Fernandez, A.; Bustamante, A.; Lopes, R. T.

    2018-04-01

    Nose ornaments from the tomb of the `Lady of Cao', a mummified woman representative of the Moche culture and dated to the third-or-fourth century AD, were analyzed by X-ray digital radiography. These spectacular gold and silver jewels are some of the most sophisticated metalworking ever produced in ancient America. The Mochecivilization flourished along the north coast of present-day Peru, between the Andes and the Pacific Ocean, approximately between 100 and 600 AD. The Moche were very sophisticated artisans and metal smiths, being considered the finest producers of jewels and artifacts of the region. A portable X-ray digital radiography (XDR) system consisting of a flat panel detector with high resolution image and a mini X-ray tube was used for the structural analysis of the Moche jewels aiming at inferring different joining methods of the silver-gold sheets. The radiographic analysis showed some differences in the joint of the silver-and-gold sheets. Presence of filler material and adhesive for joining the silver-and-gold sheets was visible as well as silver-gold junctions without filler material (or with a material invisible in radiography). Furthermore, the technique demonstrated the advantage of using a portable XDR micro system when the sample cannot be brought to the laboratory.

  10. Portable digital electronic radiography system

    International Nuclear Information System (INIS)

    Sawicka, B.D.

    1995-01-01

    Radiography is a standard nondestructive technique in the industrial testing of materials and components. It is routinely used during the construction, maintenance and repair of nuclear plants. Traditionally, radiography is performed using photographic film (film radiography, FR). Recent developments in solid-state area imaging radiation detectors, miniature electronics and computer software/hardware techniques have brought electronic alternatives to FR. In recent years various electronic radiography (ER) techniques have served as alternatives to FR, these proved beneficial in some applications. While originally developed to provide real time imaging, ER may offer other advantages over FR, depending on the application. Work was undertaken at CRL to review progress in ER techniques and evaluate the possibility of constructing a portable DER (digital electronic radiography) system, for the inspection of power plant components. A suitable DER technique has been developed and a proof of principle portable system constructed. As this paper demonstrates, a properly designed ER system can be small and compact, while providing radiographic examination with acceptable image quality and the benefits of ER imaging. The CRL DER system can operate with radioactive sources typical of FR. While it does not replace FR, our DER system is expected to be beneficial in specific applications for Candu maintenance, reducing cost, labour and time. Practical, cost saving applications of this system are expected to include valve monitoring and foreign object location during maintenance at Candu reactors

  11. Should 3K zoom function be used for detection of pneumothorax in cesium iodide/amorphous silicon flat-panel detector radiographs presented on 1K-matrix soft copies?

    International Nuclear Information System (INIS)

    Herrmann, Karin A.; Zech, C.J.; Reiser, M.F.; Bonel, H.M.; Staebler, A.; Voelk, M.; Strotzer, M.

    2006-01-01

    The purpose of the study was to evaluate observer performance in the detection of pneumothorax with cesium iodide and amorphous silicon flat-panel detector radiography (CsI/a-Si FDR) presented as 1K and 3K soft-copy images. Forty patients with and 40 patients without pneumothorax diagnosed on previous and subsequent digital storage phosphor radiography (SPR, gold standard) had follow-up chest radiographs with CsI/a-Si FDR. Four observers confirmed or excluded the diagnosis of pneumothorax according to a five-point scale first on the 1K soft-copy image and then with help of 3K zoom function (1K monitor). Receiver operating characteristic (ROC) analysis was performed for each modality (1K and 3K). The area under the curve (AUC) values for each observer were 0.7815, 0.7779, 0.7946 and 0.7066 with 1K-matrix soft copies and 0.8123, 0.7997, 0.8078 and 0.7522 with 3K zoom. Overall detection of pneumothorax was better with 3K zoom. Differences between the two display methods were not statistically significant in 3 of 4 observers (p-values between 0.13 and 0.44; observer 4: p=0.02). The detection of pneumothorax with 3K zoom is better than with 1K soft copy but not at a statistically significant level. Differences between both display methods may be subtle. Still, our results indicate that 3K zoom should be employed in clinical practice. (orig.)

  12. Digital detection systems for projection radiography

    International Nuclear Information System (INIS)

    Schulz, R.F.

    2001-01-01

    This article gives a survey of digital X-ray detection systems for projection radiography. The different principles are compared and some general characteristics are derived. The basic conversion mechanisms in the absorption layers are described. The basic principles of solid state X-ray detectors and their general characteristics are elucidated as well as some similarities with detectors for computed tomography. Some important application and system aspects are considered. An outlook on further possible developments in this field is given. (orig.) [de

  13. Proton radiography using highpower femtosecond laser

    International Nuclear Information System (INIS)

    Choi, Chang Il

    2010-08-01

    A femtosecond laser emits pulses whose width is between few and few hundreds femtoseconds (10 -15 s). The production mechanism of the high energy protons generated by the femtosecond laser is not clear so far, but the technologies have been improving. The applications using the generated protons are the proton therapy, proton radiography, nuclear physics, security inspection, and so on. Especially in the radiography, the laser-generated protons are very useful to obtain high quality images of thin objects, because protons are able to penetrate an object following an almost straight path and give a depth distribution information of various elements in a subject. Since the laser-driven protons require lower cost and smaller facility than accelerator-based protons, the radiography using laser-driven protons have been of interest. In this research, we have performed the radiography experiments by using protons generated by the 100 TW titanium sapphire femtosecond laser facility of Advanced Photonics Research Institute (APRI) of Gwangju Institute of Science Technology (GIST). A CR-39 Solid State Nuclear Track Detector (SSNTD) has been used as radiography screen. The radiography digital images have been obtained by using an optical microscope and a CCD camera. Modulation Transfer Function (MTF) has been derived from analyzing the obtained images, and the spatial resolution of the images have been evaluated. And, we have performed the radiography experiments of monoenergetic proton from the Tandem Van de Graaff accelerator of Korea Institute of Geoscience and Mineral Resources (KIGAM). We have obtained and compared the radiography images from other proton production methods which are the laser and the accelerator, respectively. And also, we have found out the optimized chemical etching condition, in order to improve the spatial resolution of the radiography images. Finally, the evaluated maximum spatial resolution of the images are 2.09 μm

  14. Comparison of dose and image quality of a Flat-panel detector and an image intensifier

    International Nuclear Information System (INIS)

    Lazzaro, M.; Friedrich, B.Q.; Luz, R.M. da; Silva, A.M.M. da

    2016-01-01

    With the development of new technologies, have emerged new conversion methods of X-ray image, such as flat panel detectors. The aim of this work is the comparison of entrance surface air kerma (ESAK) and image quality between an image intensifier type of detector (A) and a flat panel (B). The ESAK was obtained by placing a ionization chamber under PMMA simulators of 10, 20 and 30 cm and the image quality was obtained by using the TOR "1"8FG simulator. The ESAK to the equipment A is higher when compared to the equipment B. The high contrast resolution is better for the equipment A for all thicknesses of simulators. The equipment A has low contrast resolution with a better viewing threshold for thicknesses of 10 and 20 cm, and a worse performance for 30 cm. It is concluded that the equipment B has ESAK smaller and despite having lower resolution, in almost all cases, have appropriate image quality for diagnosis. (author)

  15. Low material budget floating strip Micromegas for ion transmission radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bortfeldt, J., E-mail: jonathan.bortfeldt@cern.ch [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Biebel, O.; Flierl, B.; Hertenberger, R.; Klitzner, F.; Lösel, Ph. [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Magallanes, L. [LMU Munich, LS Parodi, Am Coulombwall 1, D-85748 Garching (Germany); University Hospital Heidelberg, Im Neuenheimer Feld 672, D-69120 Heidelberg (Germany); Müller, R. [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Parodi, K. [LMU Munich, LS Parodi, Am Coulombwall 1, D-85748 Garching (Germany); Heidelberg Ion-Beam Therapy Center, Im Neuenheimer Feld 450, D-69120 Heidelberg (Germany); Schlüter, T. [LMU Munich, Excellence Cluster Universe, Boltzmannstr. 2, D-85748 Garching (Germany); Voss, B. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstr. 1, D-64291 Darmstadt (Germany); Zibell, A. [JMU Würzburg, Sanderring 2, D-97070 Würzburg (Germany)

    2017-02-11

    Floating strip Micromegas are high-accuracy and discharge insensitive gaseous detectors, able to track single particles at fluxes of 7 MHz/cm{sup 2} with 100 μm resolution. We developed low-material-budget detectors with one-dimensional strip readout, suitable for tracking at highest particle rates as encountered in medical ion transmission radiography or inner tracker applications. Recently we additionally developed Kapton-based floating strip Micromegas with two-dimensional strip readout, featuring an overall thickness of 0.011 X{sub 0}. These detectors were tested in high-rate proton and carbon-ion beams at the tandem accelerator in Garching and the Heidelberg Ion-Beam Therapy Center, operated with an optimized Ne:CF{sub 4} gas mixture. By coupling the Micromegas detectors to a new scintillator based range detector, ion transmission radiographies of PMMA and tissue-equivalent phantoms were acquired. The range detector with 18 layers is read out via wavelength shifting fibers, coupled to a multi-anode photomultiplier. We present the performance of the Micromegas detectors with respect to timing and single plane track reconstruction using the μTPC method. We discuss the range resolution of the scintillator range telescope and present the image reconstruction capabilities of the combined system.

  16. Apparatus for proton radiography

    International Nuclear Information System (INIS)

    Martin, R.L.

    1976-01-01

    An apparatus for effecting diagnostic proton radiography of patients in hospitals comprises a source of negative hydrogen ions, a synchrotron for accelerating the negative hydrogen ions to a predetermined energy, a plurality of stations for stripping extraction of a radiography beam of protons, means for sweeping the extracted beam to cover a target, and means for measuring the residual range, residual energy, or percentage transmission of protons that pass through the target. The combination of information identifying the position of the beam with information about particles traversing the subject and the back absorber is performed with the aid of a computer to provide a proton radiograph of the subject. In an alternate embodiment of the invention, a back absorber comprises a plurality of scintillators which are coupled to detectors. 10 claims, 7 drawing figures

  17. Fast neutron radiography using photoluminescent imaging plates

    International Nuclear Information System (INIS)

    Rant, J.; Kristof, E.; Balasko, M.; Stade, J.

    1999-01-01

    Fast neutron radiography (FNR) and resonance neutron radiography (RNR) are complementary to the conventional radiography with high energy gamma-rays or brems-strahlung radiation used for the inspection of thick metal objects. In both non-destructive methods, the contrast sensitivity and the penetration power can be improved by using higher energy neutrons. At present direct techniques based either n Solid State Nuclear Track detectors (SSNTDs) or scintillating screens and transfer techniques using activation threshold detectors and radiographic films are applied for the detection of fast neutron images. Rather low detection sensitivity of film and SSNTD based fast neutron imaging methods and also rather poor inherent image contrast of SSNTD pose a problem for FNR in the fast neutron energy region 1-15 MeV interesting for NDT. For more efficient detection of fast neutron images the use of novel highly sensitive photoluminescent imaging plates (IP) in combination with threshold at the KFKI research reactor. The conventional IP produced by FUJI Photo Film Co. for the detection of beta and X-ray radiation were used. The threshold activation detectors were the reactions 115 In(n, n') 115m In, 64 Zn(n,p) 64 Cu, 56 Fe(n, p) 56 Mn, 24 Mg(n, p) 24 Na and 27 Al(n, α) 24 Na. These threshold reactions cover the fast neutron energy region between 0,7 MeV and 12 MeV. Pure, commercially available metals 0,1 mm to 0,25 mm thick made of In, Zn, Fe, Mg and Al were used as converter screens. The very high sensitivity of IP, the linearity of their response over 5 decades of exposure dose and the high dynamic digitalisation latitude enabled fast neutron radiography of image quality comparable to the quality of thermal NR. In our experimental conditions (φ n ∼ 10 8 n/cm 2 s, R Cd ∼ 2) the neutron exposure and IP exposure periods were still practical and comparable to the half life of the corresponding reaction products (half an hour to several hours). Even with the 27 Al(n.α) 24

  18. Recent advances in fast neutron radiography for cargo inspection

    International Nuclear Information System (INIS)

    Sowerby, B.D.; Tickner, J.R.

    2007-01-01

    Fast neutron radiography techniques are attractive for screening cargo for contraband such as narcotics and explosives. Neutrons have the required penetration, they interact with matter in a manner complementary to X-rays and they can be used to determine elemental composition. Compared to neutron interrogation techniques that measure secondary radiation (neutron or gamma-rays), neutron radiography systems are much more efficient and rapid and they are much more amenable to imaging. However, for neutron techniques to be successfully applied to cargo screening, they must demonstrate significant advantages over well-established X-ray techniques. This paper reviews recent developments and applications of fast neutron radiography for cargo inspection. These developments include a fast neutron and gamma-ray radiography system that utilizes a 14 MeV neutron generator as well as fast neutron resonance radiography systems that use variable energy quasi-monoenergetic neutrons and pulsed broad energy neutron beams. These systems will be discussed and compared with particular emphasis on user requirements, sources, detector systems, imaging ability and performance

  19. A forward bias method for lag correction of an a-Si flat panel detector

    International Nuclear Information System (INIS)

    Starman, Jared; Tognina, Carlo; Partain, Larry; Fahrig, Rebecca

    2012-01-01

    Purpose: Digital a-Si flat panel (FP) x-ray detectors can exhibit detector lag, or residual signal, of several percent that can cause ghosting in projection images or severe shading artifacts, known as the radar artifact, in cone-beam computed tomography (CBCT) reconstructions. A major contributor to detector lag is believed to be defect states, or traps, in the a-Si layer of the FP. Software methods to characterize and correct for the detector lag exist, but they may make assumptions such as system linearity and time invariance, which may not be true. The purpose of this work is to investigate a new hardware based method to reduce lag in an a-Si FP and to evaluate its effectiveness at removing shading artifacts in CBCT reconstructions. The feasibility of a novel, partially hardware based solution is also examined. Methods: The proposed hardware solution for lag reduction requires only a minor change to the FP. For pulsed irradiation, the proposed method inserts a new operation step between the readout and data collection stages. During this new stage the photodiode is operated in a forward bias mode, which fills the defect states with charge. A Varian 4030CB panel was modified to allow for operation in the forward bias mode. The contrast of residual lag ghosts was measured for lag frames 2 and 100 after irradiation ceased for standard and forward bias modes. Detector step response, lag, SNR, modulation transfer function (MTF), and detective quantum efficiency (DQE) measurements were made with standard and forward bias firmware. CBCT data of pelvic and head phantoms were also collected. Results: Overall, the 2nd and 100th detector lag frame residual signals were reduced 70%-88% using the new method. SNR, MTF, and DQE measurements show a small decrease in collected signal and a small increase in noise. The forward bias hardware successfully reduced the radar artifact in the CBCT reconstruction of the pelvic and head phantoms by 48%-81%. Conclusions: Overall, the

  20. Dynamic neutron radiography instrumentation and applications in Central Europe

    International Nuclear Information System (INIS)

    Balasko, M.

    1996-01-01

    Characteristic features of simultaneous dynamic neutron and gamma radiography installations built in the last ten years at the Budapest/Hungary and at the Seibersdorf/Austria research reactors are surveyed. For image detection scintillation detectors and a low-light level television camera with video output are used, thereby providing the possibility for visualizing medium speed movements inside the investigated object. The radiography stations have been used for inspecting industrial products, with the aim of research and development. (orig.)

  1. Practical expressions describing detective quantum efficiency in flat-panel detectors

    Science.gov (United States)

    Kim, H. K.

    2011-11-01

    In radiology, image quality excellence is a balance between system performance and patient dose, hence x-ray systems must be designed to ensure the maximum image quality is obtained for the lowest consistent dose. The concept of detective quantum efficiency (DQE) is widely used to quantify, understand, measure, and predict the performance of x-ray detectors and imaging systems. Cascaded linear-systems theory can be used to estimate DQE based on the system design parameters and this theoretical DQE can be utilized for determining the impact of various physical processes, such as secondary quantum sinks, noise aliasing, reabsorption noise, and others. However, the prediction of DQE usually requires tremendous efforts to determine each parameter consisting of the cascaded linear-systems model. In this paper, practical DQE formalisms assessing both the photoconductor- and scintillator-based flat-panel detectors under quantum-noise-limited operation are described. The developed formalisms are experimentally validated and discussed for their limits. The formalisms described in this paper would be helpful for the rapid prediction of the DQE performances of developing systems as well as the optimal design of systems.

  2. Computer radiography - indirect digital radiography

    International Nuclear Information System (INIS)

    Jezierski, G.

    2008-01-01

    Implementation of the new European standards for industrial radiography with the use of storage phosphor imaging plates will result in the arousing of interest among numerous laboratories in non-destructive testing with application of the new method of testing to replace conventional radiography used so far, i.e. film radiography. Computer radiography is quite commonly used for medical radiography, where the fundamental problem consists in reduction of the radiation dose during the examination of a patient. However, it must be kept in mind that industrial applications have a little bit different requirements when compared with medical radiography. The article describes only new method for radiographic testing. (author)

  3. TU-E-217BCD-06: Cone Beam Breast CT with a High Resolution Flat Panel Detector-Improvement of Calcification Visibility.

    Science.gov (United States)

    Shen, Y; Zhong, Y; Lai, C; Wang, T; Shaw, C

    2012-06-01

    To investigate the advantage of a high resolution flat panel detector for improving the visibility of microcalcifications (MCs) in cone beam breast CT Methods: A paraffin cylinder was used to simulate a 100% adipose breast. Calcium carbonate grains, ranging from 125-140 μm to 224 - 250 μm in size, were used to simulate the MCs. Groups of 25 same size MCs were embedded at the phantom center. The phantom was scanned with a bench-top CBCT system at various exposure levels. A 75μm pitch flat panel detector (Dexela 2923, Perkin Elmer) with 500μm thick CsI scintillator plate was used as the high resolution detector. A 194 μm pitch detector (Paxscan 4030CB, Varian Medical Systems) was used for reference. 300 projection images were acquired over 360° and reconstructed. The images were reviewed by 6 readers. The MC visibility was quantified as the fraction of visible MCs and averaged for comparison. The visibility was plotted as a function of the estimated dose level for various MC sizes and detectors. The MTFs and DQEs were measured and compared. For imaging small (200 μm and smaller) MCs, the visibility achieved with the 75μm pitch detector was found to be significantly higher than those achieved with the 194μm pitch detector. For imaging larger MCs, there was little advantage in using the 75μm pitch detector. Using the 75μm pitch detector, MCs as small as 180 μm could be imaged to achieve a visibility of 78% with an isocenter tissue dose of ∼20 mGys versus 62% achieved with the 194 μm pitch detector at the same dose level. It was found that a high pitch flat panel detector had the advantages of extending its imaging capability to higher frequencies thus helping improve the visibility when used to image small MCs. This work was supported in part by grants CA104759, CA13852 and CA124585 from NIH-NCI, a grant EB00117 from NIH-NIBIB, and a subcontract from NIST-ATP. © 2012 American Association of Physicists in Medicine.

  4. Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules.

    Science.gov (United States)

    Dobbins, James T; McAdams, H Page; Sabol, John M; Chakraborty, Dev P; Kazerooni, Ella A; Reddy, Gautham P; Vikgren, Jenny; Båth, Magnus

    2017-01-01

    Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board-approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3-20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3-4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P chest radiography for all nodules (1.49-fold, P chest radiography, as given by the area under the receiver operating characteristic curve (1.23-fold, P chest radiography or tomosynthesis. Conclusion Tomosynthesis outperformed conventional chest radiography for lung nodule detection and determination of case management; DE imaging did not show significant differences over conventional chest

  5. Methodology for digital radiography simulation using the Monte Carlo code MCNPX for industrial applications

    International Nuclear Information System (INIS)

    Souza, E.M.; Correa, S.C.A.; Silva, A.X.; Lopes, R.T.; Oliveira, D.F.

    2008-01-01

    This work presents a methodology for digital radiography simulation for industrial applications using the MCNPX radiography tally. In order to perform the simulation, the energy-dependent response of a BaFBr imaging plate detector was modeled and introduced in the MCNPX radiography tally input. In addition, a post-processing program was used to convert the MCNPX radiography tally output into 16-bit digital images. Simulated and experimental images of a steel pipe containing corrosion alveoli and stress corrosion cracking were compared, and the results showed good agreement between both images

  6. Use of a solar panel as a directionally sensitive large-area radiation monitor for direct and scattered x-rays and gamma-rays.

    Science.gov (United States)

    Abdul-Majid, S

    1987-01-01

    The characteristics of a 25.4 X 91 cm solar cell panel used as an x-ray and gamma-ray radiation monitor are presented. Applications for monitoring the primary x-ray beam are described at different values of operating currents and voltages as well as for directional dependence of scattered radiation. Other applications in gamma-ray radiography are also given. The detector showed linear response to both x-ray and gamma-ray exposures. The equipment is rigid, easy to use, relatively inexpensive and requires no power supply or any complex electronic equipment.

  7. Theoretical and experimental comparison of proton and helium-beam radiography using silicon pixel detectors

    Science.gov (United States)

    Gehrke, T.; Amato, C.; Berke, S.; Martišíková, M.

    2018-02-01

    Ion-beam radiography (iRAD) could potentially improve the quality control of ion-beam therapy. The main advantage of iRAD is the possibility to directly measure the integrated stopping power. Until now there is no clinical implementation of iRAD. Topics of ongoing research include developing dedicated detection systems to achieve the desired spatial resolution (SR) and investigating different ion types as imaging radiation. This work focuses on the theoretical and experimental comparison of proton (pRAD) and helium-beam radiography (αRAD). The experimental comparison was performed with an in-house developed detection system consisting of silicon pixel detectors. This system enables the measurement of energy deposition of single ions, their tracking, and the identification of the ion type, which is important for αRAD due to secondary fragments. A 161 mm-thick PMMA phantom with an air gap of 1 mm placed at different depths was imaged with a 168 MeV u-1 proton/helium-ion beam at the Heidelberg ion-beam therapy center. The image quality in terms of SR and contrast-to-noise ratio (CNR) was evaluated. After validating MC simulations against experiments, pRAD and αRAD were compared to carbon-beam radiography (cRAD) in simulations. The theoretical prediction that the CNR of pRAD and αRAD is equal at similar imaging doses was experimentally confirmed. The measured SR of αRAD was 55% better compared to pRAD. The simulated cRads showed the expected improvement in SR and the decreased CNR at the same dose compared to the αRads, however only at dose levels exceeding typical doses of diagnostic x-ray projections. For clinically applicable dose levels, the cRads suffered from an insufficient number of carbon ions per pixel (220 μm  ×  220 μm). In conclusion, it was theoretically and experimentally shown that αRAD provides a better SR than pRAD without any disadvantages concerning the CNR. Using carbon ions instead of helium ions leads to a better SR at the

  8. Basic performance and stability of a CdTe solid-state detector panel.

    Science.gov (United States)

    Tsuchiya, Katsutoshi; Takahashi, Isao; Kawaguchi, Tsuneaki; Yokoi, Kazuma; Morimoto, Yuuichi; Ishitsu, Takafumi; Suzuki, Atsurou; Ueno, Yuuichirou; Kobashi, Keiji

    2010-05-01

    We have developed a prototype gamma camera system (R1-M) using a cadmium telluride (CdTe) detector panel and evaluated the basic performance and the spectral stability. The CdTe panel consists of 5-mm-thick crystals. The field of view is 134 x 268 mm comprising 18,432 pixels with a pixel pitch of 1.4 mm. Replaceable small CdTe modules are mounted on to the circuit board by dedicated zero insertion force connectors. To make the readout circuit compact, the matrix read out is processed by dedicated ASICs. The panel is equipped with a cold-air cooling system. The temperature and humidity in the panel were kept at 20 degrees C and below 70% relative humidity. CdTe polarization was suppressed by the bias refresh technique to stabilize the detector. We also produced three dedicated square pixel-matched collimators: LEGP (20 mm-thick), LEHR (27 mm-thick), and LEUHR (35 mm-thick). We evaluated their basic performance (energy resolution, system resolution, and sensitivity) and the spectral stability in terms of short-term (several hours of continuous acquisition) and long-term (infrequent measurements over more than a year) activity. The intrinsic energy resolution (FWHM) acquired with Tc-99m (140.5 keV) was 6.6%. The spatial resolutions (FWHM at a distance of 100 mm) with LEGP, LEHR, and LEUHR collimators were 5.7, 4.9, and 4.2 mm, and the sensitivities were 71, 39, and 23 cps/MBq, respectively. The energy peak position and the intrinsic energy resolution after several hours of operation were nearly the same as the values a few minutes after the system was powered on; the variation of the peak position was <0.2%, and that of the resolution was about 0.3%. Infrequent measurements conducted over a year showed that the variations of the energy peak position and the intrinsic energy resolution of the system were at a similar level to those described above. The basic performance of the CdTe-gamma camera system was evaluated, and its stability was verified. It was shown that the

  9. Development of flat panel X-ray detector utilizing a CdZnTe film as conversion layer

    International Nuclear Information System (INIS)

    Tokuda, Satoshi; Kishihara, Hiroyuki; Kaino, Masatomo; Sato, Toshiyuki

    2006-01-01

    A polycrystalline CdZnTe film formed by the CSS (closed-spaced sublimation) method is one of the most promising materials as a conversion layer of next-generation highly efficient flat-panel X-ray detectors. Therefore, we have developed a prototype of a new flat-panel X-ray detector (a sensing region of 3 inches by 3 inches) with the film and evaluated its commercial feasibility. This paper describes evaluation of the physical and imaging properties of the prototype and explains the features of the CdZnTe film and the construction, specifications, and fabrication procedures of the prototype. Also included in this paper are formation of a semiconductor thin film barrier layer by the CBD (chemical bath deposition) method and conjunction of a sensor substrate and a TFT array substrate with the bump electrodes formed by screen printing, both of which we have developed during the course of the development of the prototype. (author)

  10. Quality assurance of computed and digital radiography systems

    International Nuclear Information System (INIS)

    Walsh, C.; Gorman, D.; Byrne, P.; Larkin, A.; Dowling, A.; Malone, J. F.

    2008-01-01

    Computed radiography (CR) and digital radiography (DR) are replacing traditional film screen radiography as hospitals move towards digital imaging and picture archiving and communication systems (PACS). Both IPEM and KCARE have recently published quality assurance and acceptance testing guidelines for DR. In this paper, the performance of a range of CR and DR systems is compared. Six different manufacturers are included. Particular attention is paid to the performance of the systems under automatic exposure control (AEC). The patient is simulated using a range of thicknesses of tissue equivalent material. Image quality assessment was based on detector assessment protocols and includes pixel value measures as well as subjective assessment using Leeds Test Objects. The protocols for detector assessment cover a broad range of tests and in general detectors (whether DR or CR) performed satisfactorily. The chief limitation in performing these tests was that not all systems provided ready access to pixel values. Subjective tests include the use of the Leeds TO20. As part of this work, suggested reference values are provided to calculate the TO20 image quality factor. One consequence of moving from film screen to digital technologies is that the dynamic range of digital detectors is much wider, and increased exposures are no longer evident from changes in image quality. As such, AEC is a key parameter for CR and DR. Dose was measured using a standard phantom as a basic means of comparing systems. In order to assess the AEC performance, exit doses were also measured while varying phantom thickness. Signal-to-noise ratios (SNRs) were calculated on a number of systems where pixel values were available. SNR was affected by the selection of acquisition protocol. Comparisons between different technologies and collation of data will help refine acceptance thresholds and contribute to optimising dose and image quality. (authors)

  11. Contrast optimization in X-ray radiography with single photon counting imagers of Medipix type

    Czech Academy of Sciences Publication Activity Database

    Jandejsek, Ivan; Dammer, J.; Jakůbek, J.; Vavřík, Daniel; Žemlička, J.

    2012-01-01

    Roč. 7, C12011 (2012), s. 1-5 ISSN 1748-0221. [International Workshop on Radiation Imaging Detectors /14./. Figueira da Foz, Coimbra, 01.07.2012-05.07.2012] R&D Projects: GA ČR GAP105/11/1551 Grant - others:GA MKO(CZ) DF12P01OVV048 Institutional support: RVO:68378297 Keywords : X-ray detectors * X-ray radiography and digital radiography * inspection with x-rays Subject RIV: JB - Sensors, Measurment, Regulation Impact factor: 1.869, year: 2011 http://iopscience.iop.org/1748-0221/7/12/C12011/

  12. Solar panels as air Cherenkov detectors for extremely high energy cosmic rays

    International Nuclear Information System (INIS)

    Cecchini, S.; D'Antone, I.; Degli Esposti, L.; Giacomelli, G.; Guerra, M.; Lax, I.; Mandrioli, G.; Parretta, A.; Sarno, A.; Schioppo, R.; Sorel, M.; Spurio, M.

    2000-01-01

    Increasing interest towards the observation of the highest energy cosmic rays has motivated the development of new detection techniques. The properties of the Cherenkov photon pulse emitted in the atmosphere by these very rare particles indicate low-cost semiconductor detectors as good candidates for their optical read-out. The aim of this paper is to evaluate the viability of solar panels for this purpose. The experimental framework resulting from measurements performed with suitably-designed solar cells and large conventional photovoltaic areas is presented. A discussion on the obtained and achievable sensitivities follows

  13. Neutron Focusing Mirrors for Neutron Radiography of Irradiated Nuclear Fuel at Idaho National Laboratory

    Science.gov (United States)

    Rai, Durgesh K.; Wu, Huarui; Abir, Muhammad; Giglio, Jeffrey; Khaykovich, Boris

    Post irradiation examination (PIE) of samples irradiated in nuclear reactors is a challenging but necessary task for the development on novel nuclear power reactors. Idaho National Laboratory (INL) has neutron radiography capabilities, which are especially useful for the PIE of irradiated nuclear fuel. These capabilities are limited due to the extremely high gamma-ray radiation from the irradiated fuel, which precludes the use of standard digital detectors, in turn limiting the ability to do tomography and driving the cost of the measurements. In addition, the small 250 kW Neutron Radiography Reactor (NRAD) provides a relatively weak neutron flux, which leads to low signal-to-noise ratio. In this work, we develop neutron focusing optics suitable for the installation at NRAD. The optics would separate the sample and the detector, potentially allowing for the use of digital radiography detectors, and would provide significant intensity enhancement as well. The optics consist of several coaxial nested Wolter mirrors and is suited for polychromatic thermal neutron radiation. Laboratory Directed Research and Development program of Idaho National Laboratory.

  14. Digital radiography using amorphous selenium: photoconductively activated switch (PAS) readout system.

    Science.gov (United States)

    Reznik, Nikita; Komljenovic, Philip T; Germann, Stephen; Rowlands, John A

    2008-03-01

    A new amorphous selenium (a-Se) digital radiography detector is introduced. The proposed detector generates a charge image in the a-Se layer in a conventional manner, which is stored on electrode pixels at the surface of the a-Se layer. A novel method, called photoconductively activated switch (PAS), is used to read out the latent x-ray charge image. The PAS readout method uses lateral photoconduction at the a-Se surface which is a revolutionary modification of the bulk photoinduced discharge (PID) methods. The PAS method addresses and eliminates the fundamental weaknesses of the PID methods--long readout times and high readout noise--while maintaining the structural simplicity and high resolution for which PID optical readout systems are noted. The photoconduction properties of the a-Se surface were investigated and the geometrical design for the electrode pixels for a PAS radiography system was determined. This design was implemented in a single pixel PAS evaluation system. The results show that the PAS x-ray induced output charge signal was reproducible and depended linearly on the x-ray exposure in the diagnostic exposure range. Furthermore, the readout was reasonably rapid (10 ms for pixel discharge). The proposed detector allows readout of half a pixel row at a time (odd pixels followed by even pixels), thus permitting the readout of a complete image in 30 s for a 40 cm x 40 cm detector with the potential of reducing that time by using greater readout light intensity. This demonstrates that a-Se based x-ray detectors using photoconductively activated switches could form a basis for a practical integrated digital radiography system.

  15. The Delphi technique in radiography education research

    International Nuclear Information System (INIS)

    John-Matthews, J.St.; Wallace, M.J.; Robinson, L.

    2017-01-01

    Objectives: To describe and review the Delphi technique as a tool for radiographers engaged in mixed-methods research whereby agreement is required on the proficiencies needed by educational programmes for pre- and post- registration radiographers. This is achieved through a description offering a brief history of the technique. Through a literature search, radiography education research using this technique is identified. A protocol for a research project using the technique is presented. Using this worked example, advantages and disadvantages of the method are explored including sampling of participants, sample size, number of rounds and methods of feedback. Key findings: There are limited examples of the use of the Delphi technique in radiography literature including considerations on how to select experts and panel size. Conclusion: The Delphi technique is a suitable method for establishing collective agreement in the design of radiography educational interventions. Additional research is needed to deepen this evidence-based knowledge. - Highlights: • The Delphi Technique is used to gain collective agreement in forecasting healthcare education priorities. • There is increase of the use of the technique in healthcare education literature. • There are some examples of the technique in radiography education research. • A worked example of this technique is provided to critically evaluate this tool.

  16. [Digital thoracic radiology: devices, image processing, limits].

    Science.gov (United States)

    Frija, J; de Géry, S; Lallouet, F; Guermazi, A; Zagdanski, A M; De Kerviler, E

    2001-09-01

    In a first part, the different techniques of digital thoracic radiography are described. Since computed radiography with phosphore plates are the most commercialized it is more emphasized. But the other detectors are also described, as the drum coated with selenium and the direct digital radiography with selenium detectors. The other detectors are also studied in particular indirect flat panels detectors and the system with four high resolution CCD cameras. In a second step the most important image processing are discussed: the gradation curves, the unsharp mask processing, the system MUSICA, the dynamic range compression or reduction, the soustraction with dual energy. In the last part the advantages and the drawbacks of computed thoracic radiography are emphasized. The most important are the almost constant good quality of the pictures and the possibilities of image processing.

  17. Simulation of image detectors in radiology for determination of scatter-to-primary ratios using Monte Carlo radiation transport code MCNP/MCNPX.

    Science.gov (United States)

    Smans, Kristien; Zoetelief, Johannes; Verbrugge, Beatrijs; Haeck, Wim; Struelens, Lara; Vanhavere, Filip; Bosmans, Hilde

    2010-05-01

    The purpose of this study was to compare and validate three methods to simulate radiographic image detectors with the Monte Carlo software MCNP/MCNPX in a time efficient way. The first detector model was the standard semideterministic radiography tally, which has been used in previous image simulation studies. Next to the radiography tally two alternative stochastic detector models were developed: A perfect energy integrating detector and a detector based on the energy absorbed in the detector material. Validation of three image detector models was performed by comparing calculated scatter-to-primary ratios (SPRs) with the published and experimentally acquired SPR values. For mammographic applications, SPRs computed with the radiography tally were up to 44% larger than the published results, while the SPRs computed with the perfect energy integrating detectors and the blur-free absorbed energy detector model were, on the average, 0.3% (ranging from -3% to 3%) and 0.4% (ranging from -5% to 5%) lower, respectively. For general radiography applications, the radiography tally overestimated the measured SPR by as much as 46%. The SPRs calculated with the perfect energy integrating detectors were, on the average, 4.7% (ranging from -5.3% to -4%) lower than the measured SPRs, whereas for the blur-free absorbed energy detector model, the calculated SPRs were, on the average, 1.3% (ranging from -0.1% to 2.4%) larger than the measured SPRs. For mammographic applications, both the perfect energy integrating detector model and the blur-free energy absorbing detector model can be used to simulate image detectors, whereas for conventional x-ray imaging using higher energies, the blur-free energy absorbing detector model is the most appropriate image detector model. The radiography tally overestimates the scattered part and should therefore not be used to simulate radiographic image detectors.

  18. A study of television imaging system for fast neutron radiography

    International Nuclear Information System (INIS)

    Yoshii, Koji

    1992-01-01

    The neutron radiography with fast neutron beam is a very useful imaging technique for thicker objects, especially those composed of hydrogen-rich materials which are sometimes difficult to image by thermal neutron radiography. The fast neutron radiography has not been studied so much as the thermal neutron radiography. The fast neutron radiography has been studied at the fast neutron source reactor 'Yayoi' of the University of Tokyo built in Tokai-mura. The average neutron energy of the Yayoi is about 1 MeV, and the peak neutron flux at the core center is 0.8 x 10 12 at the maximum operating power of 2 kW. In the experiment on fast neutron radiography, a CR39 nuclear track detector has been used successfully. But in the Yayoi radiography procedure, about 24 hours were required for obtaining an imaging result. To get a prompt imaging result and a real-time imaging result, it is necessary to develop a fast neutron television system, and in this paper, a new fast neutron TV system is proposed. The main difference is the converter material sensitive to fast neutrons. The study on the fast neutron TV system was carried out by using the Baby Cyclotron of Japan Steel Works, and the good images were realized. (K.I.)

  19. High resolution X-ray imaging of bone-implant interface by large area flat-panel detector

    International Nuclear Information System (INIS)

    Kytyr, D; Jirousek, O; Dammer, J

    2011-01-01

    The aim of the research was to investigate the cemented bone-implant interface behavior (cement layer degradation and bone-cement interface debonding) with emphasis on imaging techniques suitable to detect the early defects in the cement layer. To simulate in vivo conditions a human pelvic bone was implanted with polyurethane acetabular cup using commercial acrylic bone cement. The implanted cup was then loaded in a custom hip simulator to initiate fatigue crack propagation in the bone cement. The pelvic bone was then repetitively scanned in a micro-tomography device. Reconstructed tomography images showed failure processes that occurred in the cement layer during the first 250,000 cycles. A failure in cemented acetabular implant - debonding, crumbling and smeared cracks - has been found to be at the bone-cement interface. Use of micro-focus source and high resolution flat panel detector of large physical dimensions allowed to reconstruct the micro-structural models suitable for investigation of migration, micro-motions and consecutive loosening of the implant. The large area flat panel detector with physical dimensions 120 x 120mm with 50μm pixel size provided a superior image quality compared to clinical CT systems with 300-150μm pixel size.

  20. Assessment of cold neutron radiography capability

    International Nuclear Information System (INIS)

    McDonald, T.E. Jr.; Roberts, J.A.

    1998-01-01

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The authors goals were to demonstrate and assess cold neutron radiography techniques at the Los Alamos Neutron Science Center (LANSCE), Manual Lujan Neutron Scattering Center (Lujan Center), and to investigate potential applications of the capability. The authors have obtained images using film and an amorphous silicon detector. In addition, a new technique they have developed allows neutron radiographs to be made using only a narrow range of neutron energies. Employing this approach and the Bragg cut-off phenomena in certain materials, they have demonstrated material discrimination in radiography. They also demonstrated the imaging of cracks in a sample of a fire-set case that was supplied by Sandia National Laboratory, and they investigated whether the capability could be used to determine the extent of coking in jet engine nozzles. The LANSCE neutron radiography capability appears to have applications in the DOE stockpile maintenance and science-based stockpile stewardship (SBSS) programs, and in industry

  1. Non-streaming high-efficiency perforated semiconductor neutron detectors, methods of making same and measuring wand and detector modules utilizing same

    Science.gov (United States)

    McGregor, Douglas S.; Shultis, John K.; Rice, Blake B.; McNeil, Walter J.; Solomon, Clell J.; Patterson, Eric L.; Bellinger, Steven L.

    2010-12-21

    Non-streaming high-efficiency perforated semiconductor neutron detectors, method of making same and measuring wands and detector modules utilizing same are disclosed. The detectors have improved mechanical structure, flattened angular detector responses, and reduced leakage current. A plurality of such detectors can be assembled into imaging arrays, and can be used for neutron radiography, remote neutron sensing, cold neutron imaging, SNM monitoring, and various other applications.

  2. Characterization of Makrofol ® DE 1-1 for alpha particle radiography

    Science.gov (United States)

    El Ghazaly, M.; Aydarous, Abdulkadir; Al-Thomali, Talal A.

    2017-09-01

    Makrofol ® DE 1-1 (bisphenol-A polycarbonate) was investigated for alpha particle radiography. The edge spread function (ESF) was measured by razor-blade's edge. Makrofol ® DE 1-1 detectors were irradiated with perpendicular incident alpha particles of energy 2.5, 4 and 5.4 MeV, thereafter they were etched in 75% 6N KOH+25% C2H5OH at a temperature of 50 °C for different durations. The etched Makrofol®DE 1-1 detectors were imaged with an optical microscope equipped with a CCD camera. The results revealed that the green channel of the original RGB image provides the highest contrast comparing with red and blue channel by a factor of 27.6% of the original RGB image. The image contrast of alpha particle-irradiated Makrofol®DE 1-1 detector was found to be inversely related to the etching time since the alpha particle tracks proceed from a conical phase to spherical phase. The spatial resolution of alpha particle-irradiated Makrofol®DE 1-1 detector, in terms of line spread function, was found to deteriorate as the etching time increases for all examined alpha particle energies. The results revealed the potential capability of Makrofol®DE 1-1 detector as an efficient detector for alpha particle radiography such as autoradiography.

  3. High-quality 3D correction of ring and radiant artifacts in flat panel detector-based cone beam volume CT imaging

    Science.gov (United States)

    Abu Anas, Emran Mohammad; Kim, Jae Gon; Lee, Soo Yeol; Kamrul Hasan, Md

    2011-10-01

    The use of an x-ray flat panel detector is increasingly becoming popular in 3D cone beam volume CT machines. Due to the deficient semiconductor array manufacturing process, the cone beam projection data are often corrupted by different types of abnormalities, which cause severe ring and radiant artifacts in a cone beam reconstruction image, and as a result, the diagnostic image quality is degraded. In this paper, a novel technique is presented for the correction of error in the 2D cone beam projections due to abnormalities often observed in 2D x-ray flat panel detectors. Template images are derived from the responses of the detector pixels using their statistical properties and then an effective non-causal derivative-based detection algorithm in 2D space is presented for the detection of defective and mis-calibrated detector elements separately. An image inpainting-based 3D correction scheme is proposed for the estimation of responses of defective detector elements, and the responses of the mis-calibrated detector elements are corrected using the normalization technique. For real-time implementation, a simplification of the proposed off-line method is also suggested. Finally, the proposed algorithms are tested using different real cone beam volume CT images and the experimental results demonstrate that the proposed methods can effectively remove ring and radiant artifacts from cone beam volume CT images compared to other reported techniques in the literature.

  4. High-quality 3D correction of ring and radiant artifacts in flat panel detector-based cone beam volume CT imaging

    International Nuclear Information System (INIS)

    Anas, Emran Mohammad Abu; Hasan, Md Kamrul; Kim, Jae Gon; Lee, Soo Yeol

    2011-01-01

    The use of an x-ray flat panel detector is increasingly becoming popular in 3D cone beam volume CT machines. Due to the deficient semiconductor array manufacturing process, the cone beam projection data are often corrupted by different types of abnormalities, which cause severe ring and radiant artifacts in a cone beam reconstruction image, and as a result, the diagnostic image quality is degraded. In this paper, a novel technique is presented for the correction of error in the 2D cone beam projections due to abnormalities often observed in 2D x-ray flat panel detectors. Template images are derived from the responses of the detector pixels using their statistical properties and then an effective non-causal derivative-based detection algorithm in 2D space is presented for the detection of defective and mis-calibrated detector elements separately. An image inpainting-based 3D correction scheme is proposed for the estimation of responses of defective detector elements, and the responses of the mis-calibrated detector elements are corrected using the normalization technique. For real-time implementation, a simplification of the proposed off-line method is also suggested. Finally, the proposed algorithms are tested using different real cone beam volume CT images and the experimental results demonstrate that the proposed methods can effectively remove ring and radiant artifacts from cone beam volume CT images compared to other reported techniques in the literature.

  5. Standard practice for radiologic examination of flat panel composites and sandwich core materials used in aerospace applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice is intended to be used as a supplement to Practices E 1742, E 1255, and E 2033. 1.2 This practice describes procedures for radiologic examination of flat panel composites and sandwich core materials made entirely or in part from fiber-reinforced polymer matrix composites. Radiologic examination is: a) radiographic (RT) with film, b) Computed Radiography (CR) with Imaging Plate, c) Digital Radiology (DR) with Digital Detector Array’s (DDA), and d) Radioscopic (RTR) Real Time Radiology with a detection system such as an Image Intensifier. The composite materials under consideration typically contain continuous high modulus fibers (> 20 GPa), such as those listed in 1.4. 1.3 This practice describes established radiological examination methods that are currently used by industry that have demonstrated utility in quality assurance of flat panel composites and sandwich core materials during product process design and optimization, process control, after manufacture inspection, in service exami...

  6. Performance evaluation of a retrofit digital detector-based mammography system.

    Science.gov (United States)

    Marshall, Nicholas W; van Ongeval, Chantal; Bosmans, Hilde

    2016-02-01

    A retrofit flat panel detector was integrated with a GE DMR+ analog mammography system and characterized using detective quantum efficiency (DQE). Technical system performance was evaluated using the European Guidelines protocol, followed by a limited evaluation of clinical image quality for 20 cases using image quality criteria in the European Guidelines. Optimal anode/filter selections were established using signal difference-to-noise ratio measurements. Only small differences in peak DQE were seen between the three anode/filter settings, with an average value of 0.53. For poly(methyl methacrylate) (PMMA) thicknesses above 60 mm, the Rh/Rh setting was the optimal anode/filter setting. The system required a mean glandular dose of 0.54 mGy at 30 kV Rh/Rh to reach the Acceptable gold thickness limit for 0.1 mm details. Imaging performance of the retrofit unit with the GE DMR+ is notably better than of powder based computed radiography systems and is comparable to current flat panel FFDM systems. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Radiography with polarised neutrons

    International Nuclear Information System (INIS)

    Schulz, Michael L.

    2010-01-01

    In this thesis I present a new technique for the spatially resolved investigation of the magnetic properties of bulk samples. Standard one dimensional neutron depolarisation analysis is combined with neutron radiography to a method we call Neutron Depolarisation Imaging (NDI). The experimental setup which was installed at the neutron radiography beam line ANTARES at FRM II consists of a double crystal monochromator, neutron polariser, spin flipper, polarisation analyser and a position sensitive CCD detector. A comprehensive discussion of the requirements for these components is given and the limitations of the method are shown. The maximum spatial resolution which can be achieved with a neutron radiography setup is determined by the collimation of the neutron beam and the distance between sample and detector. Different types of polarisers have been tested and their advantages and disadvantages are discussed. A double crystal monochromator and a new type of polariser employing polarising neutron supermirrors based on the principle of an optical periscope were developed and tested during this work. Furthermore, NDI measurements on various samples of the weakly ferromagnetic materials Pd 1-x Ni x and Ni 3 Al are presented. Neutron depolarisation radiography and tomography measurements were conducted with a spatial resolution as high as 0.3 mm on Pd 1-x Ni x and Ni 3 Al samples. The feasibility of NDI experiments under hydrostatic pressures up to 10 kbar was shown on a sample of Ni 3 Al using a modified Cu:Be clamp cell. A decrease of the ordering temperature by 2 K under hydrostatic pressure was determined from the NDI measurements and shows the potential of the method for further high pressure experiments. Additionally a method was developed which in principle allows to obtain the intrinsic dependence of the ordering temperature T C on the ordered moment Ms from NDI measurements on inhomogeneous samples containing regions with different ordering temperatures. This

  8. Cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS flat panel detector: visibility of simulated microcalcifications.

    Science.gov (United States)

    Shen, Youtao; Zhong, Yuncheng; Lai, Chao-Jen; Wang, Tianpeng; Shaw, Chris C

    2013-10-01

    To measure and investigate the improvement of microcalcification (MC) visibility in cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS/CsI flat panel detector (Dexela 2923, Perkin Elmer). Aluminum wires and calcium carbonate grains of various sizes were embedded in a paraffin cylinder to simulate imaging of calcifications in a breast. Phantoms were imaged with a benchtop experimental cone beam CT system at various exposure levels. In addition to the Dexela detector, a high pitch (50 μm), thin (150 μm) scintillator CMOS/CsI flat panel detector (C7921CA-09, Hamamatsu Corporation, Hamamatsu City, Japan) and a widely used low pitch (194 μm), thick (600 μm) scintillator aSi/CsI flat panel detector (PaxScan 4030CB, Varian Medical Systems) were also used in scanning for comparison. The images were independently reviewed by six readers (imaging physicists). The MC visibility was quantified as the fraction of visible MCs and measured as a function of the estimated mean glandular dose (MGD) level for various MC sizes and detectors. The modulation transfer functions (MTFs) and detective quantum efficiencies (DQEs) were also measured and compared for the three detectors used. The authors have demonstrated that the use of a high pitch (75 μm) CMOS detector coupled with a thick (500 μm) CsI scintillator helped make the smaller 150-160, 160-180, and 180-200 μm MC groups more visible at MGDs up to 10.8, 9, and 10.8 mGy, respectively. It also made the larger 200-212 and 212-224 μm MC groups more visible at MGDs up to 7.2 mGy. No performance improvement was observed for 224-250 μm or larger size groups. With the higher spatial resolution of the Dexela detector based system, the apparent dimensions and shapes of MCs were more accurately rendered. The results show that with the aforementioned detector, a 73% visibility could be achieved in imaging 160-180 μm MCs as compared to 28% visibility achieved by the low pitch (194 μm) aSi/CsI flat

  9. Optimizing detector thickness in dual-shot dual-energy x-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Woon; Kam, Soohwa; Youn, Hanbean; Kim, Ho Kyung [Pusan National University, Busan (Korea, Republic of)

    2015-05-15

    As a result, there exist apparent limitations in the conventional two-dimensional (2D) radiography: One is that the contrast between the structure of interest and the background in a radiograph is much less than the intrinsic subject contrast (i.e. the difference between their attenuation coefficients; Another is that the superimposed anatomical structures in the 2D radiograph results in an anatomical background clutter that may decrease the conspicuity of subtle underlying features. These limitations in spatial and material discrimination are important motivations for the recent development of 3D (e.g. tomosynthesis) and dual energy imaging (DEI) systems. DEI technique uses a combination of two images obtained at two different energies in successive x-ray exposures by rapidly switching the kilovolage (kV) applied to the x-ray tube. Commercial DEI systems usually employ a 'single' of flat-panel detector (FPD) to obtain two different kV images. However, we have a doubt in the use of the same detector for acquiring two different projections for the low- and high-kV setups because it is typically known that there exists an optimal detector thickness regarding specific imaging tasks or energies used.

  10. Spectral correction algorithm for multispectral CdTe x-ray detectors

    DEFF Research Database (Denmark)

    Christensen, Erik D.; Kehres, Jan; Gu, Yun

    2017-01-01

    Compared to the dual energy scintillator detectors widely used today, pixelated multispectral X-ray detectors show the potential to improve material identification in various radiography and tomography applications used for industrial and security purposes. However, detector effects, such as charge...

  11. Muon radiography for exploration of Mars geology

    Directory of Open Access Journals (Sweden)

    S. Kedar

    2013-06-01

    Full Text Available Muon radiography is a technique that uses naturally occurring showers of muons (penetrating particles generated by cosmic rays to image the interior of large-scale geological structures in much the same way as standard X-ray radiography is used to image the interior of smaller objects. Recent developments and application of the technique to terrestrial volcanoes have demonstrated that a low-power, passive muon detector can peer deep into geological structures up to several kilometers in size, and provide crisp density profile images of their interior at ten meter scale resolution. Preliminary estimates of muon production on Mars indicate that the near horizontal Martian muon flux, which could be used for muon radiography, is as strong or stronger than that on Earth, making the technique suitable for exploration of numerous high priority geological targets on Mars. The high spatial resolution of muon radiography also makes the technique particularly suited for the discovery and delineation of Martian caverns, the most likely planetary environment for biological activity. As a passive imaging technique, muon radiography uses the perpetually present background cosmic ray radiation as the energy source for probing the interior of structures from the surface of the planet. The passive nature of the measurements provides an opportunity for a low power and low data rate instrument for planetary exploration that could operate as a scientifically valuable primary or secondary instrument in a variety of settings, with minimal impact on the mission's other instruments and operation.

  12. Substitution of the radiographic plaques for photographic paper for x-ray radiography

    International Nuclear Information System (INIS)

    Fernandez, L.M.; Sanchez, C.

    1994-01-01

    The german photo paper Afga-Gevaert and the chinese Friendship were used as detectors for X-ray radiography, of steel specimens, together with the amplifier screens Perlux (Germany) and Standard (Russian). A wide energy range (80-240 Kv) and steel specimen thickness (5-25 mm) were tested. The exposition monograph for radiography control which comply both DIN 54109 and the GOST 7512-82 standards was obtained. A methodology allowing the use of the photo paper was made

  13. The MU-RAY project: detector technology and first data from Mt. Vesuvius

    International Nuclear Information System (INIS)

    Ambrosino, F; Cimmino, L; Garufi, F; Lauria, A; Masone, V; Anastasio, A; Basta, D; Energico, S; Bonechi, L; Brianzi, M; Ciaranfi, R; Bross, A; Callier, S; Taille, C de La; Caputo, A; D'Auria, L; Giudicepietro, F; Macedonio, G; Martini, M; D'Alessandro, R

    2014-01-01

    Muon Radiography allows to map the density of a volcanic cone. It is based on the measurement of the attenuation of the flux of muons present in the cosmic radiation on the ground. The MU-RAY project has developed an innovative detector designed for the muon radiography. The main features are the low electric power consumption, robustness and transportability, good spatial resolution and muon time of flight measurement. A 1 m 2 detector prototype has been constructed. and collected data at Mt. Vesuvius for approximately 1 month in spring 2013. A second campaign of measurement has been performed at the Puy de Dôme, France, in the last four months of 2013. In this article the principles of muon radiography, the MU-RAY detector and the first results from the collected data will be described

  14. Development of Portable Digital Radiography System with a Device for Monitoring X-ray Source-Detector Angle and Its Application in Chest Imaging

    Directory of Open Access Journals (Sweden)

    Tae-Hoon Kim

    2017-03-01

    Full Text Available This study developed a device measuring the X-ray source-detector angle (SDA and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR was evaluated using the signal-to-noise (SNR, contrast-to-noise ratio (CNR, spatial resolution, distortion and entrance surface dose (ESD. According to different angle degrees, five anatomical landmarks were assessed using a five-point scale. The mean SNR and CNR were 182.47 and 141.43. The spatial resolution and ESD were 3.17 lp/mm (157 μm and 0.266 mGy. The angle values of the SDA device were not significantly difference as compared to those of the digital angle meter. In chest imaging, the SNR and CNR values were not significantly different according to the different angle degrees. The visibility scores of the border of the heart, the fifth rib and the scapula showed significant differences according to different angles (p < 0.05, whereas the scores of the clavicle and first rib were not significant. It is noticeable that the increase in the SDA degree was consistent with the increases of the distortion and visibility score. The proposed PDR with a SDA device would be useful for application in the clinical radiography setting according to the standard radiography guidelines.

  15. A novel radiation detector for removing scattered radiation in chest radiography: Monte Carlo simulation-based performance evaluation

    Science.gov (United States)

    Roh, Y. H.; Yoon, Y.; Kim, K.; Kim, J.; Kim, J.; Morishita, J.

    2016-10-01

    Scattered radiation is the main reason for the degradation of image quality and the increased patient exposure dose in diagnostic radiology. In an effort to reduce scattered radiation, a novel structure of an indirect flat panel detector has been proposed. In this study, a performance evaluation of the novel system in terms of image contrast as well as an estimation of the number of photons incident on the detector and the grid exposure factor were conducted using Monte Carlo simulations. The image contrast of the proposed system was superior to that of the no-grid system but slightly inferior to that of the parallel-grid system. The number of photons incident on the detector and the grid exposure factor of the novel system were higher than those of the parallel-grid system but lower than those of the no-grid system. The proposed system exhibited the potential for reduced exposure dose without image quality degradation; additionally, can be further improved by a structural optimization considering the manufacturer's specifications of its lead contents.

  16. Magnifying lens for 800 MeV proton radiography

    International Nuclear Information System (INIS)

    Merrill, F. E.; Campos, E.; Espinoza, C.; Hogan, G.; Hollander, B.; Lopez, J.; Mariam, F. G.; Morley, D.; Morris, C. L.; Murray, M.; Saunders, A.; Schwartz, C.; Thompson, T. N.

    2011-01-01

    This article describes the design and performance of a magnifying magnetic-lens system designed, built, and commissioned at the Los Alamos National Laboratory (LANL) for 800 MeV flash proton radiography. The technique of flash proton radiography has been developed at LANL to study material properties under dynamic loading conditions through the analysis of time sequences of proton radiographs. The requirements of this growing experimental program have resulted in the need for improvements in spatial radiographic resolution. To meet these needs, a new magnetic lens system, consisting of four permanent magnet quadrupoles, has been developed. This new lens system was designed to reduce the second order chromatic aberrations, the dominant source of image blur in 800 MeV proton radiography, as well as magnifying the image to reduce the blur contribution from the detector and camera systems. The recently commissioned lens system performed as designed, providing nearly a factor of three improvement in radiographic resolution.

  17. Focusing mirrors for enhanced neutron radiography with thermal neutrons and application for irradiated nuclear fuel

    Science.gov (United States)

    Rai, Durgesh K.; Abir, Muhammad; Wu, Huarui; Khaykovich, Boris; Moncton, David E.

    2018-01-01

    Neutron radiography is a powerful method of probing the structure of materials based on attenuation of neutrons. This method is most suitable for materials containing heavy metals, which are not transparent to X-rays, for example irradiated nuclear fuel and other nuclear materials. Neutron radiography is one of the first non-distractive post-irradiated examination methods, which is applied to gain an overview of the integrity of irradiated nuclear fuel and other nuclear materials. However, very powerful gamma radiation emitted by the samples is damaging to the electronics of digital imaging detectors and has so far precluded the use of modern detectors. Here we describe a design of a neutron microscope based on focusing mirrors suitable for thermal neutrons. As in optical microscopes, the sample is separated from the detector, decreasing the effect of gamma radiation. In addition, the application of mirrors would result in a thirty-fold gain in flux and a resolution of better than 40 μm for a field-of-view of about 2.5 cm. Such a thermal neutron microscope can be useful for other applications of neutron radiography, where thermal neutrons are advantageous.

  18. Neutron radiography

    International Nuclear Information System (INIS)

    Hrdlicka, Z.

    1977-01-01

    Neutron radiography is a radiographic method using a neutron beam of a defined geometry. The neutron source usually consists of a research reactor, a specialized neutron radiography reactor or the 252 Cf radioisotope source. There are two types of the neutron radiography display system, viz., a system producing neutron radiography images by a photographic process or a system allowing a visual display, eg., using a television monitor. The method can be used wherever X-ray radiography is used except applications in the radiography of humans. The neutron radiography unit at UJV uses the WWR-S reactor as the neutron source and both types of the above mentioned display system. (J.P.)

  19. Comparison of the perceived image quality between two digital imaging systems for neonatal bedside radiography – A case study

    International Nuclear Information System (INIS)

    Zyl, S.A. van; Kekana, R.M.

    2015-01-01

    Background: Chest X-rays are performed daily in the neonatal intensive care and high care units. The skill of the radiographer is critical for obtaining the best image quality and limiting the patient's radiation exposure. The literature states that indirect flat panel detectors produce images of superior quality in comparison to computed radiography systems. At Steve Biko Academic Hospital a decision was made to revert from the direct digital radiography (DR) system to the computed radiography (CR) system, due to poor image quality experienced. Method: The case study objective was to conduct a comparative analysis describing key technical factors contributing to image quality. The analysis entailed retrospectively comparing the images obtained during 2010 and 2011. An image analysis form was utilised in evaluating the technical aspects of the image. A total of 160 images were viewed by 16 participants sampled from the radiography, radiology and paediatric departments. The participants were asked to re-evaluate two of their allotted images after five days to determine their reliability. Results: Findings were that the DR system provides significantly better image quality than the CR system (p < 0.05) for all the technical factors evaluated. However technical improvements are recommended. A wide variance in intra-observer reliability was also found. Conclusion: This case study demonstrated that DR images were considered to be superior to CR images. Recommendations include: a standardised technique for imaging the neonates; optimisation of the imaging software for the digital detectors, improved feedback systems in terms of exposure index values, and the training of radiographers and referring physicians in technical image analysis. - Highlights: • DR system provides better image quality than the CR system for all technical factors evaluated. • The average values obtained from the VAS showed that the DR system still needs to be optimised. • There is need

  20. Digital radiography using scintillating screens

    International Nuclear Information System (INIS)

    Salvini, E.

    1988-01-01

    This paper briefly describes the technical features of a digital radiographic system based on the principle of scanning laser stimulated luminescence. Such aspects as the physics of the stimulable phosphor detector are dealt with, and image acquisition, processing, and hard-copy output. Automatic analysis of pixel histograms is described, in a qualitative way, together with contrast modifications and spatial filtering. Physical image characteristics are reported. The overall performance of digital radiography is examined, together with the current requirements and its eventual developments

  1. Evaluation of a flat panel digital radiographic system for low-dose portable imaging of neonates

    International Nuclear Information System (INIS)

    Samei, Ehsan; Hill, Jeanne G.; Frey, G. Donald; Southgate, W. Michael; Mah, Eugene; Delong, David

    2003-01-01

    The purpose of this study was to evaluate the clinical utility of an investigational flat-panel digital radiography system for low-dose portable neonatal imaging. Thirty image-pairs from neonatal intensive care unit patients were acquired with a commercial Computed Radiography system (Agfa, ADC 70), and with the investigational system (Varian, Paxscan 2520) at one-quarter of the exposure. The images were evaluated for conspicuity and localization of the endings of ancillary catheters and tubes in two observer performance experiments with three pediatric radiologists and three neonatologists serving as observers. The results indicated no statistically significant difference in diagnostic quality between the images from the investigational system and from CR. Given the investigational system's superior resolution and noise characteristics, observer results suggest that the high detective quantum efficiency of flat-panel digital radiography systems can be utilized to decrease the radiation dose/exposure to neonatal patients, although post-processing of the images remains to be optimized. The rapid availability of flat-panel images in portable imaging was found to be an added advantage for timely clinical decision-making

  2. Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging

    International Nuclear Information System (INIS)

    Liu Xinming; Shaw, Chris C.; Lai, Chao-Jen; Wang Tianpeng

    2011-01-01

    Purpose: To investigate and compare the scatter rejection properties and low-contrast performance of the scan equalization digital radiography (SEDR) technique to the slot-scan and conventional full-field digital radiography techniques for chest imaging. Methods: A prototype SEDR system was designed and constructed with an a-Se flat-panel (FP) detector to improve image quality in heavily attenuating regions of an anthropomorphic chest phantom. Slot-scanning geometry was used to reject scattered radiation without attenuating primary x rays. The readout scheme of the FP was modified to erase accumulated scatter signals prior to image readout. A 24-segment beam width modulator was developed to regulate x-ray exposures regionally and compensate for the low x-ray flux in heavily attenuating regions. To measure the scatter-to-primary ratios (SPRs), a 2 mm thick lead plate with a 2-D array of aperture holes was used to measure the primary signals, which were then subtracted from those obtained without the lead plate to determine scatter components. A 2-D array of aluminum beads (3 mm in diameter) was used as the low-contrast objects to measure the contrast ratios (CRs) and contrast-to-noise ratios (CNRs) for evaluating the low-contrast performance in chest phantom images. A set of two images acquired with the same techniques were subtracted from each other to measure the noise levels. SPRs, CRs, and CNRs of the SEDR images were measured in four anatomical regions of chest phantom images and compared to those of slot-scan images and full-field images acquired with and without antiscatter grid. Results: The percentage reduction of SPR (percentage of SPRs reduced with scatter removal/rejection methods relative to that for nongrid full-field imaging) averaged over four anatomical regions was measured to be 80%, 83%, and 71% for SEDR, slot-scan, and full-field with grid, respectively. The average CR over four regions was found to improve over that for nongrid full

  3. Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging

    Energy Technology Data Exchange (ETDEWEB)

    Liu Xinming; Shaw, Chris C.; Lai, Chao-Jen; Wang Tianpeng [Department of Imaging Physics, Digital Imaging Research Laboratory, University of Texas M. D. Anderson Cancer Center, Houston, Texas 77030-4009 (United States)

    2011-01-15

    Purpose: To investigate and compare the scatter rejection properties and low-contrast performance of the scan equalization digital radiography (SEDR) technique to the slot-scan and conventional full-field digital radiography techniques for chest imaging. Methods: A prototype SEDR system was designed and constructed with an a-Se flat-panel (FP) detector to improve image quality in heavily attenuating regions of an anthropomorphic chest phantom. Slot-scanning geometry was used to reject scattered radiation without attenuating primary x rays. The readout scheme of the FP was modified to erase accumulated scatter signals prior to image readout. A 24-segment beam width modulator was developed to regulate x-ray exposures regionally and compensate for the low x-ray flux in heavily attenuating regions. To measure the scatter-to-primary ratios (SPRs), a 2 mm thick lead plate with a 2-D array of aperture holes was used to measure the primary signals, which were then subtracted from those obtained without the lead plate to determine scatter components. A 2-D array of aluminum beads (3 mm in diameter) was used as the low-contrast objects to measure the contrast ratios (CRs) and contrast-to-noise ratios (CNRs) for evaluating the low-contrast performance in chest phantom images. A set of two images acquired with the same techniques were subtracted from each other to measure the noise levels. SPRs, CRs, and CNRs of the SEDR images were measured in four anatomical regions of chest phantom images and compared to those of slot-scan images and full-field images acquired with and without antiscatter grid. Results: The percentage reduction of SPR (percentage of SPRs reduced with scatter removal/rejection methods relative to that for nongrid full-field imaging) averaged over four anatomical regions was measured to be 80%, 83%, and 71% for SEDR, slot-scan, and full-field with grid, respectively. The average CR over four regions was found to improve over that for nongrid full

  4. ACR Appropriateness Criteria® Routine Chest Radiography.

    Science.gov (United States)

    McComb, Barbara L; Chung, Jonathan H; Crabtree, Traves D; Heitkamp, Darel E; Iannettoni, Mark D; Jokerst, Clinton; Saleh, Anthony G; Shah, Rakesh D; Steiner, Robert M; Mohammed, Tan-Lucien H; Ravenel, James G

    2016-03-01

    Chest radiographs are sometimes taken before surgeries and interventional procedures on hospital admissions and outpatients. This manuscript summarizes the American College of Radiology review of the literature and recommendations on routinely performed chest radiographies in these settings. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed every 3 years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer-reviewed journals and the application of a well-established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances in which evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment.

  5. Flat-panel detectors: how much better are they?

    International Nuclear Information System (INIS)

    Seibert, J.A.

    2006-01-01

    Interventional and fluoroscopic imaging procedures for pediatric patients are becoming more prevalent because of the less-invasive nature of these procedures compared to alternatives such as surgery. Flat-panel X-ray detectors (FPD) for fluoroscopy are a new technology alternative to the image intensifier/TV (II/TV) digital system that has been in use for more than two decades. Two major FPD technologies have been implemented, based on indirect conversion of X-rays to light (using an X-ray scintillator) and then to proportional charge (using a photodiode), or direct conversion of X-rays into charge (using a semiconductor material) for signal acquisition and digitization. These detectors have proved very successful for high-exposure interventional procedures but lack the image quality of the II/TV system at the lowest exposure levels common in fluoroscopy. The benefits for FPD image quality include lack of geometric distortion, little or no veiling glare, a uniform response across the field-of-view, and improved ergonomics with better patient access. Better detective quantum efficiency indicates the possibility of reducing the patient dose in accordance with ALARA principles. However, first-generation FPD devices have been implemented with less than adequate acquisition flexibility (e.g., lack of tableside controls/information, inability to easily change protocols) and the presence of residual signals from previous exposures, and additional cost of equipment and long-term maintenance have been serious impediments to purchase and implementation. Technological advances of second generation and future hybrid FPD systems should solve many current issues. The answer to the question ''how much better are they?'' is ''significantly better'', and they are certainly worth consideration for replacement or new implementation of an imaging suite for pediatric fluoroscopy. (orig.)

  6. System for uncollimated digital radiography

    Science.gov (United States)

    Wang, Han; Hall, James M.; McCarrick, James F.; Tang, Vincent

    2015-08-11

    The inversion algorithm based on the maximum entropy method (MEM) removes unwanted effects in high energy imaging resulting from an uncollimated source interacting with a finitely thick scintillator. The algorithm takes as input the image from the thick scintillator (TS) and the radiography setup geometry. The algorithm then outputs a restored image which appears as if taken with an infinitesimally thin scintillator (ITS). Inversion is accomplished by numerically generating a probabilistic model relating the ITS image to the TS image and then inverting this model on the TS image through MEM. This reconstruction technique can reduce the exposure time or the required source intensity without undesirable object blurring on the image by allowing the use of both thicker scintillators with higher efficiencies and closer source-to-detector distances to maximize incident radiation flux. The technique is applicable in radiographic applications including fast neutron, high-energy gamma and x-ray radiography using thick scintillators.

  7. Comparative study between computed radiography and conventional radiography

    International Nuclear Information System (INIS)

    Noorhazleena Azaman; Khairul Anuar Mohd Salleh; Sapizah Rahim; Shaharudin Sayuti; Arshad Yassin; Abdul Razak Hamzah

    2010-01-01

    In Industrial Radiography, there are many criteria that need to be considered based on established standards to accept or reject the radiographic film. For conventional radiography, we need to consider the optical density by using the densitometer when viewing the film on the viewer. But in the computed radiography (CR) we need to evaluate and performed the analysis from the quality of the digital image through grey value. There are many factors that affected the digital image quality. One of the factors which are affected to the digital image quality in the image processing is grey value that related to the contrast resolution. In this work, we performed grey value study measurement on digital radiography systems and compared it with exposed films in conventional radiography. The test sample is a steel step wedge. We found out the contrast resolution is higher in Computed Radiography compared with Conventional Radiography. (author)

  8. Digital radiography in space.

    Science.gov (United States)

    Hart, Rob; Campbell, Mark R

    2002-06-01

    With the permanent habitation of the International Space Station, the planning of longer duration exploration missions, and the possibility of space tourism, it is likely that digital radiography will be needed in the future to support medical care in space. Ultrasound is currently the medical imaging modality of choice for spaceflight. Digital radiography in space is limited because of prohibitive launch costs (in the region of $20,000/kg) that severely restrict the volume, weight, and power requirements of medical care hardware. Technological increases in radiography, a predicted ten-fold decrease in future launch costs, and an increasing clinical need for definitive medical care in space will drive efforts to expand the ability to provide medical care in space including diagnostic imaging. Normal physiological responses to microgravity, in conjunction with the high-risk environment of spaceflight, increase the risk of injury and could imply an extended recovery period for common injuries. The advantages of gravity on Earth, such as the stabilization of patients undergoing radiography and the drainage of fluids, which provide radiographic contrast, are unavailable in space. This creates significant difficulties in patient immobilization and radiographic positioning. Gravity-dependent radiological signs, such as lipohemarthrosis in knee and shoulder trauma, air or fluid levels in pneumoperitoneum, pleural effusion, or bowel obstruction, and the apical pleural edge in pneumothorax become unavailable. Impaired healing processes such as delayed callus formation following fracture will have implications on imaging, and recovery time lines are unknown. The confined nature of spacecraft and the economic impossibility of launching lead-based personal protective equipment present significant challenges to crew radiation safety. A modified, free-floating radiographic C-arm device equipped with a digital detector and utilizing teleradiology support is proposed as a

  9. Semiconductor Pixel detectors and their applications in life sciences

    International Nuclear Information System (INIS)

    Jakubek, J

    2009-01-01

    Recent advances in semiconductor technology allow construction of highly efficient and low noise pixel detectors of ionizing radiation. Steadily improving quality of front end electronics enables fast digital signal processing in each pixel which offers recording of more complete information about each detected quantum (energy, time, number of particles). All these features improve an extend applicability of pixel technology in different fields. Some applications of this technology especially for imaging in life sciences will be shown (energy and phase sensitive X-ray radiography and tomography, radiography with heavy charged particles, neutron radiography, etc). On the other hand a number of obstacles can limit the detector performance if not handled. The pixel detector is in fact an array of individual detectors (pixels), each of them has its own efficiency, energy calibration and also noise. The common effort is to make all these parameters uniform for all pixels. However an ideal uniformity can be never reached. Moreover, it is often seen that the signal in one pixel can affect the neighbouring pixels due to various reasons (e.g. charge sharing). All such effects have to be taken into account during data processing to avoid false data interpretation. A brief view into the future of pixel detectors and their applications including also spectroscopy, tracking and dosimetry is given too. Special attention is paid to the problem of detector segmentation in context of the charge sharing effect.

  10. PROTON RADIOGRAPHY WITH THE PIXEL DETECTOR TIMEPIX

    Directory of Open Access Journals (Sweden)

    Václav Olšanský

    2016-12-01

    Full Text Available This article presents the processing of radiographic data acquired using the position-sensitive hybrid semiconductor pixel detector Timepix. Measurements were made on thin samples at the medical ion-synchrotron HIT [1] in Heidelberg (Germany with a 221 MeV proton beam. The charge is energy by the particles crossing the sample is registered for generation of image contrast. Experimental data from the detector were processed for derivation of the energy loss of each proton using calibration matrices. The interaction point of the protons on the detector were determined with subpixel resolution by model fitting of the individual signals in the pixelated matrix. Three methods were used for calculation of these coordinates: Hough transformation, 2D Gaussian fitting and estimate the 2D mean. Parameters of calculation accuracy and calculation time are compared for each method. The final image was created by method with best parameters.

  11. Aging of imaging properties of a CMOS flat-panel detector for dental cone-beam computed tomography

    Science.gov (United States)

    Kim, D. W.; Han, J. C.; Yun, S.; Kim, H. K.

    2017-01-01

    We have experimentally investigated the long-term stability of imaging properties of a flat-panel detector in conditions used for dental x-ray imaging. The detector consists of a CsI:Tl layer and CMOS photodiode pixel arrays. Aging simulations were carried out using an 80-kVp x-ray beam at an air-kerma rate of approximately 5 mGy s-1 at the entrance surface of the detector with a total air kerma of up to 0.6 kGy. Dark and flood-field images were periodically obtained during irradiation, and the mean signal and noise levels were evaluated for each image. We also evaluated the modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). The aging simulation showed a decrease in both the signal and noise of the gain-offset-corrected images, but there was negligible change in the signal-to-noise performance as a function of the accumulated dose. The gain-offset correction for analyzing images resulted in negligible changes in MTF, NPS, and DQE results over the total dose. Continuous x-ray exposure to a detector can cause degradation in the physical performance factors such the detector sensitivity, but linear analysis of the gain-offset-corrected images can assure integrity of the imaging properties of a detector during its lifetime.

  12. Improvement of single detector proton radiography by incorporating intensity of time-resolved dose rate functions

    Science.gov (United States)

    Zhang, Rongxiao; Jee, Kyung-Wook; Cascio, Ethan; Sharp, Gregory C.; Flanz, Jacob B.; Lu, Hsiao-Ming

    2018-01-01

    Proton radiography, which images patients with the same type of particles as those with which they are to be treated, is a promising approach to image guidance and water equivalent path length (WEPL) verification in proton radiation therapy. We have shown recently that proton radiographs could be obtained by measuring time-resolved dose rate functions (DRFs) using an x-ray amorphous silicon flat panel. The WEPL values were derived solely from the root-mean-square (RMS) of DRFs, while the intensity information in the DRFs was filtered out. In this work, we explored the use of such intensity information for potential improvement in WEPL accuracy and imaging quality. Three WEPL derivation methods based on, respectively, the RMS only, the intensity only, and the intensity-weighted RMS were tested and compared in terms of the quality of obtained radiograph images and the accuracy of WEPL values. A Gammex CT calibration phantom containing inserts made of various tissue substitute materials with independently measured relative stopping powers (RSP) was used to assess the imaging performances. Improved image quality with enhanced interfaces was achieved while preserving the accuracy by using intensity information in the calibration. Other objects, including an anthropomorphic head phantom, a proton therapy range compensator, a frozen lamb’s head and an ‘image quality phantom’ were also imaged. Both the RMS only and the intensity-weighted RMS methods derived RSPs within  ±  1% for most of the Gammex phantom inserts, with a mean absolute percentage error of 0.66% for all inserts. In the case of the insert with a titanium rod, the method based on RMS completely failed, whereas that based on the intensity-weighted RMS was qualitatively valid. The use of intensity greatly enhanced the interfaces between different materials in the obtained WEPL images, suggesting the potential for image guidance in areas such as patient positioning and tumor tracking by proton

  13. Radiography with polarised neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Michael L.

    2010-08-20

    In this thesis I present a new technique for the spatially resolved investigation of the magnetic properties of bulk samples. Standard one dimensional neutron depolarisation analysis is combined with neutron radiography to a method we call Neutron Depolarisation Imaging (NDI). The experimental setup which was installed at the neutron radiography beam line ANTARES at FRM II consists of a double crystal monochromator, neutron polariser, spin flipper, polarisation analyser and a position sensitive CCD detector. A comprehensive discussion of the requirements for these components is given and the limitations of the method are shown. The maximum spatial resolution which can be achieved with a neutron radiography setup is determined by the collimation of the neutron beam and the distance between sample and detector. Different types of polarisers have been tested and their advantages and disadvantages are discussed. A double crystal monochromator and a new type of polariser employing polarising neutron supermirrors based on the principle of an optical periscope were developed and tested during this work. Furthermore, NDI measurements on various samples of the weakly ferromagnetic materials Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al are presented. Neutron depolarisation radiography and tomography measurements were conducted with a spatial resolution as high as 0.3 mm on Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al samples. The feasibility of NDI experiments under hydrostatic pressures up to 10 kbar was shown on a sample of Ni{sub 3}Al using a modified Cu:Be clamp cell. A decrease of the ordering temperature by 2 K under hydrostatic pressure was determined from the NDI measurements and shows the potential of the method for further high pressure experiments. Additionally a method was developed which in principle allows to obtain the intrinsic dependence of the ordering temperature T{sub C} on the ordered moment Ms from NDI measurements on inhomogeneous samples containing regions with

  14. Proton Radiography: Cross Section Measurements and Detector Development

    International Nuclear Information System (INIS)

    Longo, Michael J.

    2003-01-01

    OAK-B135 The physics goal of this project is to measure forward production of neutrons and photons produced by high-energy proton beams striking a variety of targets. This will provide data essential to proton radiography. This work is being carried out in conjunction with the Fermilab Experiment 907 (MIPP) collaboration including physicists from Lawrence Livermore Laboratory. Our group is responsible for the E907 forward neutron/photon calorimeter. The project is on track to meet its technical milestones, though the overall schedule at Fermilab has slipped. The electromagnetic calorimeter and the hadron calorimeter were both assembled and ready for testing with beam in December 2003

  15. Computed radiography versus mobile direct radiography for bedside chest radiographs: Impact of dose on image quality and reader agreement

    International Nuclear Information System (INIS)

    De Boo, D.W.; Weber, M.; Deurloo, E.E.; Streekstra, G.J.; Freling, N.J.; Dongelmans, D.A.; Schaefer-Prokop, C.M.

    2011-01-01

    Aim: To asses the image quality and potential for dose reduction of mobile direct detector (DR) chest radiography as compared with computed radiography (CR) for intensive care unit (ICU) chest radiographs (CXR). Methods and materials: Three groups of age-, weight- and disease-matched ICU patients (n = 114 patients; 50 CXR per acquisition technique) underwent clinically indicated bedside CXR obtained with either CR (single read-out powder plates) or mobile DR (GOS-TFT detectors) at identical or 50% reduced dose (DR 50% ). Delineation of anatomic structures and devices used for patient monitoring, overall image quality and disease were scored by four readers. In 12 patients pairs of follow-up CR and DR images were available, and in 15 patients pairs of CR and DR 50% images were available. In these pairs the overall image quality was also compared side-by-side. Results: Delineation of anatomy in the mediastinum was scored better with DR or DR 50% than with CR. Devices used for patient monitoring were seen best with DR, with DR 50% being superior to CR. In the side-by-side comparison, the overall image quality of DR and DR 50% was rated better than CR in 96% (46/48) and 87% (52/60), respectively. Inter-observer agreement for the assessment of pathology was fair for CR and DR 50% (κ = 0.33 and κ = 0.39, respectively) and moderate for DR (κ = 0.48). Conclusion: Mobile DR units offer better image quality than CR for bedside chest radiography and allow for 50% dose reduction. Inter-observer agreement increases with image quality and is superior with DR, while DR 50% and CR are comparable.

  16. The stationary neutron radiography system: a TRIGA-based production neutron radiography facility

    International Nuclear Information System (INIS)

    Chesworth, Robert H.; Hagmann, Dean B.

    1988-01-01

    General Atomics (GA) is under contract to construct a Stationary Neutron Radiography System (SNRS) - on a turnkey basis - at McClellan Air Force Base in Sacramento, California. The SNRS is a custom designed neutron radiography system which will utilize a 1000 KW TRIGA reactor as the neutron source. The partially below-ground reactor will be equipped with four inclined beam tubes originating near the top of the reactor graphite reflector and installed tangential to the reactor core to provide a strong current of thermal neutrons with minimum gamma ray contamination. The inclined beam tubes will terminate in four large bays and will interface with rugged component positioning systems designed to handle intact aircraft wings, other honeycomb aircraft structures, and pyrotechnics. The SNRS will be equipped with real-time, near real-time, and film radiographic imaging systems to provide a broad spectrum of capability for detection of entrained moisture or corrosion in large aircraft panels. GA is prime contractor to the Air Force for the SNRS and is specifically responsible for the TRIGA reactor system and a portion of the neutron beam system design. Science Applications International Corporation and the Lionakis-Beaumont Design Group are principal subcontractors to GA on the project. (author)

  17. Physical image quality of computed radiography in mammography system

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Muhammad Jamal Isa; Wan Muhamad Saridan Wan Hassan; Fatimah Othman

    2013-01-01

    Full-text: Mammography is a screening procedure that mostly used for early detection of breast cancer. In digital imaging system, Computed Radiography is a cost-effective technology that applied indirect conversion detector. The paper presents physical image quality parameter measurements namely modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE) of Computed Radiography in mammography system. MTF was calculated from two different orientations of slanted images of an edge test device and NNPS was estimated using flat-field image. Both images were acquired using a standard mammography beam quality. DQE was determined by applying the MTF and NNPS values into our developed software program. Both orientations have similar DQE characteristics. (author)

  18. Displacement Tracking in Single Human Trabecula with Metal-plated Micro-spheres using X-ray Radiography Imaging

    Czech Academy of Sciences Publication Activity Database

    Jiroušek, Ondřej; Kytýř, Daniel; Doktor, Tomáš; Dammer, J.; Krejčí, F.

    2013-01-01

    Roč. 8, č. 2 (2013), C02041-C02047 ISSN 1748-0221 R&D Projects: GA ČR(CZ) GAP105/10/2305 Institutional support: RVO:68378297 Keywords : pixelated detectors and associated VLSI electronic * X-ray radiography and digital radiography (DR) * single trabeculae Subject RIV: FI - Traumatology, Orthopedics Impact factor: 1.526, year: 2013 http://iopscience.iop.org/1748-0221/8/02/C02041

  19. Method and apparatus for shadow aperture backscatter radiography (SABR) system and protocol

    Science.gov (United States)

    Shedlock, Daniel (Inventor); Jacobs, Alan M. (Inventor); Jacobs, Sharon Auerback (Inventor); Dugan, Edward (Inventor)

    2010-01-01

    A shadow aperture backscatter radiography (SABR) system includes at least one penetrating radiation source for providing a penetrating radiation field, and at least one partially transmissive radiation detector, wherein the partially transmissive radiation detector is interposed between an object region to be interrogated and the radiation source. The partially transmissive radiation detector transmits a portion of the illumination radiation field. A shadow aperture having a plurality of radiation attenuating regions having apertures therebetween is disposed between the radiation source and the detector. The apertures provide illumination regions for the illumination radiation field to reach the object region, wherein backscattered radiation from the object is detected and generates an image by the detector in regions of the detector that are shadowed by the radiation attenuation regions.

  20. Characterization of a clinical unit for digital radiography based on irradiation side sampling technology

    Energy Technology Data Exchange (ETDEWEB)

    Rivetti, Stefano [Fisica Medica, Ospedale di Sassuolo S.p.A., 41049 Sassuolo (Italy); Lanconelli, Nico [Alma Mater Studiorum, Physics Department, University of Bologna, 40127 Bologna (Italy); Bertolini, Marco; Nitrosi, Andrea [Medical Physics Unit, Azienda Ospedaliera ASMN, Istituto di Ricovero e Cura a Carattere Scientifico, 42123 Reggio Emilia (Italy); Burani, Aldo [Ospedale di Sassuolo S.p.A., 41049 Sassuolo (Italy)

    2013-10-15

    Purpose: A characterization of a clinical unit for digital radiography (FUJIFILM FDR D-EVO) is presented. This system is based on the irradiation side sampling (ISS) technology and can be equipped with two different scintillators: one traditional gadolinium-oxysulphide phosphor (GOS) and a needle structured cesium iodide (CsI) phosphor panel.Methods: The characterization was achieved in terms of response curve, modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE), and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). For both scintillation screens the authors accomplished the measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9.Results: At the Nyquist frequency (3.33 lp/mm) the MTF is about 35% and 25% for CsI and GOS detectors, respectively. The CsI scintillator has better noise properties than the GOS screen in almost all the conditions. This is particularly true for low-energy beams, where the noise for the GOS system can go up to a factor 2 greater than that found for CsI. The DQE of the CsI detector reaches a peak of 60%, 60%, 58%, and 50% for the RQA3, RQA5, RQA7, and RQA9 beams, respectively, whereas for the GOS screen the maximum DQE is 40%, 44%, 44%, and 35%. The contrast-detail analysis confirms that in the majority of cases the CsI scintillator is able to provide improved outcomes to those obtained with the GOS screen.Conclusions: The limited diffusion of light produced by the ISS reading makes possible the achievement of very good spatial resolution. In fact, the MTF of the unit with the CsI panel is only slightly lower to that achieved with direct conversion detectors. The combination of very good spatial resolution, together with the good noise properties reached with the CsI screen, allows achieving DQE on average about 1.5 times greater than that obtained with GOS. In fact, the DQE of unit equipped with CsI is comparable to the best

  1. Quantitative comparison using Generalized Relative Object Detectability (G-ROD) metrics of an amorphous selenium detector with high resolution Microangiographic Fluoroscopes (MAF) and standard flat panel detectors (FPD).

    Science.gov (United States)

    Russ, M; Shankar, A; Jain, A; Setlur Nagesh, S V; Ionita, C N; Scott, C; Karim, K S; Bednarek, D R; Rudin, S

    2016-02-27

    A novel amorphous selenium (a-Se) direct detector with CMOS readout has been designed, and relative detector performance investigated. The detector features include a 25 μ m pixel pitch, and 1000 μ m thick a-Se layer operating at 10V/ μ m bias field. A simulated detector DQE was determined, and used in comparative calculations of the Relative Object Detectability (ROD) family of prewhitening matched-filter (PWMF) observer and non-prewhitening matched filter (NPWMF) observer model metrics to gauge a-Se detector performance against existing high resolution micro-angiographic fluoroscopic (MAF) detectors and a standard flat panel detector (FPD). The PWMF-ROD or ROD metric compares two x-ray imaging detectors in their relative abilities in imaging a given object by taking the integral over spatial frequencies of the Fourier transform of the detector DQE weighted by an object function, divided by the comparable integral for a different detector. The generalized-ROD (G-ROD) metric incorporates clinically relevant parameters (focal-spot size, magnification, and scatter) to show the degradation in imaging performance for detectors that are part of an imaging chain. Preliminary ROD calculations using simulated spheres as the object predicted superior imaging performance by the a-Se detector as compared to existing detectors. New PWMF-G-ROD and NPWMF-G-ROD results still indicate better performance by the a-Se detector in an imaging chain over all sphere sizes for various focal spot sizes and magnifications, although a-Se performance advantages were degraded by focal spot blurring. Nevertheless, the a-Se technology has great potential to provide breakthrough abilities such as visualization of fine details including of neuro-vascular perforator vessels and of small vascular devices.

  2. Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hall, G. N., E-mail: hall98@llnl.gov; Izumi, N.; Landen, O. L.; Tommasini, R.; Holder, J. P.; Hargrove, D.; Bradley, D. K.; Lumbard, A.; Cruz, J. G.; Piston, K.; Bell, P. M.; Carpenter, A. C.; Palmer, N. E.; Felker, B.; Rekow, V.; Allen, F. V. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States); Lee, J. J.; Romano, E. [National Security Technologies LLC, 161 S Vasco Rd., Livermore, California 94551 (United States)

    2016-11-15

    Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro-channel plate) to provide gating and high DQE at the 40–200 keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.

  3. Flat detectors and their clinical applications

    International Nuclear Information System (INIS)

    Spahn, Martin

    2005-01-01

    Diagnostic and interventional flat detector X-ray systems are penetrating the market in all application segments. First introduced in radiography and mammography, they have conquered cardiac and general angiography and are getting increasing attention in fluoroscopy. Two flat detector technologies prevail. The dominating method is based on an indirect X-ray conversion process, using cesium iodide scintillators. It offers considerable advantages in radiography, angiography and fluoroscopy. The other method employs a direct converter such as selenium which is particularly suitable for mammography. Both flat detector technologies are based on amorphous silicon active pixel matrices. Flat detectors facilitate the clinical workflow in radiographic rooms, foster improved image quality and provide the potential to reduce dose. This added value is based on their large dynamic range, their high sensitivity to X-rays and the instant availability of the image. Advanced image processing is instrumental in these improvements and expand the range of conventional diagnostic methods. In angiography and fluoroscopy the transition from image intensifiers to flat detectors is facilitated by ample advantages they offer, such as distortion-free images, excellent coarse contrast, large dynamic range and high X-ray sensitivity. These characteristics and their compatibility with strong magnetic fields are the basis for improved diagnostic methods and innovative interventional applications. (orig.)

  4. New portable 1200 W X-ray detectors

    International Nuclear Information System (INIS)

    Liebram, A.; Niemann, W.; Nielsen, J.

    2005-01-01

    The contribution presents new detectors of up to 1200 W. The new detectors by YXLON have several of the following advantages, depending on the application: a) Reduced exposure time; b) Higher contrast; c) deeper penetration. The high efficiency, the duty cycle achieved, and the low price make the instruments interesting also for stationary applications in radiography and radioscopy [de

  5. Design and image-quality performance of high resolution CMOS-based X-ray imaging detectors for digital mammography

    Science.gov (United States)

    Cha, B. K.; Kim, J. Y.; Kim, Y. J.; Yun, S.; Cho, G.; Kim, H. K.; Seo, C.-W.; Jeon, S.; Huh, Y.

    2012-04-01

    In digital X-ray imaging systems, X-ray imaging detectors based on scintillating screens with electronic devices such as charge-coupled devices (CCDs), thin-film transistors (TFT), complementary metal oxide semiconductor (CMOS) flat panel imagers have been introduced for general radiography, dental, mammography and non-destructive testing (NDT) applications. Recently, a large-area CMOS active-pixel sensor (APS) in combination with scintillation films has been widely used in a variety of digital X-ray imaging applications. We employed a scintillator-based CMOS APS image sensor for high-resolution mammography. In this work, both powder-type Gd2O2S:Tb and a columnar structured CsI:Tl scintillation screens with various thicknesses were fabricated and used as materials to convert X-ray into visible light. These scintillating screens were directly coupled to a CMOS flat panel imager with a 25 × 50 mm2 active area and a 48 μm pixel pitch for high spatial resolution acquisition. We used a W/Al mammographic X-ray source with a 30 kVp energy condition. The imaging characterization of the X-ray detector was measured and analyzed in terms of linearity in incident X-ray dose, modulation transfer function (MTF), noise-power spectrum (NPS) and detective quantum efficiency (DQE).

  6. Variation in X-ray dose quantity using an amorphous selenium based flat-panel detector - a study on the dose reduction rate up to the limit of diagnostical utilization

    International Nuclear Information System (INIS)

    Lehnert, T.; Wohlers, J.; Manegold, K.; Wetter, A.; Jacobi, V.; Mack, M.G.; Vogl, T.J.; Streng, W.

    2006-01-01

    Purpose: To evaluate the diagnostic quality and minimum required dose to obtain acceptable images for diagnostic purposes in the field of musculoskeletal radiology. Materials and methods: A critical comparison of the image quality produced by a novel flat panel detector and the conventional screen/film system using a contrast-detail phantom was performed in phase I. Images from both systems were obtained with the same dose and displayed with similar contrast and density. In phase II images of significant anatomical structures in cadaver extremities obtained using the digital detector system and the standard film/screen system were critically evaluated. After a successive reduction in the X-ray dose for 84 patients in phase III, eight independent radiologists compared the image quality of the screen/film system to that of the novel flat panel detector. Results: Phases I and II revealed a difference in the image quality achieved by the standard screen/film system and the digital detector system to the advantage of the digital detector system. In 77 of 84 patients (91.7%), phase III showed equal image quality after a 50% reduction in the X-ray dose. In 3 cases (3.6%) the image quality and the level of contrast were better. No unified statement could be made for 4 patients (4.7%). Conclusion: Digital imaging of skeletal disorders using the novel flat panel detector makes it possible to reduce the X-ray dose by 50% with equal or even better image quality. (orig.)

  7. Portable abdomen radiography. Moving to thickness-based protocols

    International Nuclear Information System (INIS)

    Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A.

    2018-01-01

    Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

  8. Portable abdomen radiography. Moving to thickness-based protocols

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A. [University of Chicago Medical Center, Department of Radiology, Chicago, IL (United States)

    2018-02-15

    Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

  9. X-Ray Radiographic Study of some Panel Painting Icons from the Beginning of the XX Century

    Directory of Open Access Journals (Sweden)

    Ioan EMANDI

    2011-09-01

    Full Text Available Nondestructive investigation methods with penetrating radiations, such as digital radiography and computed tomography proved to be very useful not only in assessing the cultural heritage, but also but also in any restoration and conservation activity by supplying a multitude of micro-structural details regarding a great diversity of works of art. Consequently, present paper presents two case studies regarding the use of digital radiography in investigating panel icons from the Popa Tatu Church, Bucharest. In both cases it was possible to evidence not only the actual state of conservation of wooden panels but also fragments of the oil picture, allowing a better planning of the future conservation work.

  10. An investigation of automatic exposure control calibration for chest imaging with a computed radiography system

    International Nuclear Information System (INIS)

    Moore, C S; Wood, T J; Beavis, A W; Saunderson, J R; Avery, G; Balcam, S; Needler, L

    2014-01-01

    The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQ m ), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQ m  and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma. (paper)

  11. An investigation of automatic exposure control calibration for chest imaging with a computed radiography system.

    Science.gov (United States)

    Moore, C S; Wood, T J; Avery, G; Balcam, S; Needler, L; Beavis, A W; Saunderson, J R

    2014-05-07

    The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQm), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQm and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma.

  12. Radiography

    Science.gov (United States)

    Gardner, C. G.

    1973-01-01

    Radiography is discussed as a method for nondestructive evaluation of internal flaws of solids. Gamma ray and X-ray equipment are described along with radiographic film, radiograph interpretation, and neutron radiography.

  13. Automatic analysis of quality of images from X-ray digital flat detectors

    International Nuclear Information System (INIS)

    Le Meur, Y.

    2009-04-01

    Since last decade, medical imaging has grown up with the development of new digital imaging techniques. In the field of X-ray radiography, new detectors replace progressively older techniques, based on film or x-ray intensifiers. These digital detectors offer a higher sensibility and reduced overall dimensions. This work has been prepared with Trixell, the world leading company in flat detectors for medical radiography. It deals with quality control on digital images stemming from these detectors. High quality standards of medical imaging impose a close analysis of the defects that can appear on the images. This work describes a complete process for quality analysis of such images. A particular focus is given on the detection task of the defects, thanks to methods well adapted to our context of spatially correlated defects in noise background. (author)

  14. Comparison of dose and image quality of a Flat-panel detector and an image intensifier; Comparacao da dose e qualidade da imagem de um detector Flatpanel e um intensificador de imagem

    Energy Technology Data Exchange (ETDEWEB)

    Lazzaro, M.; Friedrich, B.Q.; Luz, R.M. da; Silva, A.M.M. da, E-mail: marcos.lazzaro@acad.pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil)

    2016-07-01

    With the development of new technologies, have emerged new conversion methods of X-ray image, such as flat panel detectors. The aim of this work is the comparison of entrance surface air kerma (ESAK) and image quality between an image intensifier type of detector (A) and a flat panel (B). The ESAK was obtained by placing a ionization chamber under PMMA simulators of 10, 20 and 30 cm and the image quality was obtained by using the TOR {sup 18}FG simulator. The ESAK to the equipment A is higher when compared to the equipment B. The high contrast resolution is better for the equipment A for all thicknesses of simulators. The equipment A has low contrast resolution with a better viewing threshold for thicknesses of 10 and 20 cm, and a worse performance for 30 cm. It is concluded that the equipment B has ESAK smaller and despite having lower resolution, in almost all cases, have appropriate image quality for diagnosis. (author)

  15. Breast cancer detection rates using four different types of mammography detectors

    Energy Technology Data Exchange (ETDEWEB)

    Mackenzie, Alistair; Warren, Lucy M.; Dance, David R.; Young, Kenneth C. [Royal Surrey County Hospital, National Coordinating Centre for the Physics in Mammography (NCCPM), Guildford (United Kingdom); University of Surrey, Department of Physics, Guildford (United Kingdom); Wallis, Matthew G. [Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); NIHR Cambridge Biomedical Research Centre, Cambridge Breast Unit, Cambridge (United Kingdom); Cooke, Julie [Jarvis Breast Screening and Diagnostic Centre, Guildford (United Kingdom); Given-Wilson, Rosalind M. [St George' s Healthcare NHS Trust, Department of Radiology, London (United Kingdom); Chakraborty, Dev P. [University of Pittsburgh, Department of Radiology, Pittsburgh, PA (United States); Halling-Brown, Mark D. [Royal Surrey County Hospital, Scientific Computing, Department of Medical Physics, Guildford (United Kingdom); Looney, Padraig T. [Royal Surrey County Hospital, National Coordinating Centre for the Physics in Mammography (NCCPM), Guildford (United Kingdom)

    2016-03-15

    To compare the performance of different types of detectors in breast cancer detection. A mammography image set containing subtle malignant non-calcification lesions, biopsy-proven benign lesions, simulated malignant calcification clusters and normals was acquired using amorphous-selenium (a-Se) detectors. The images were adapted to simulate four types of detectors at the same radiation dose: digital radiography (DR) detectors with a-Se and caesium iodide (CsI) convertors, and computed radiography (CR) detectors with a powder phosphor (PIP) and a needle phosphor (NIP). Seven observers marked suspicious and benign lesions. Analysis was undertaken using jackknife alternative free-response receiver operating characteristics weighted figure of merit (FoM). The cancer detection fraction (CDF) was estimated for a representative image set from screening. No significant differences in the FoMs between the DR detectors were measured. For calcification clusters and non-calcification lesions, both CR detectors' FoMs were significantly lower than for DR detectors. The calcification cluster's FoM for CR NIP was significantly better than for CR PIP. The estimated CDFs with CR PIP and CR NIP detectors were up to 15 % and 22 % lower, respectively, than for DR detectors. Cancer detection is affected by detector type, and the use of CR in mammography should be reconsidered. (orig.)

  16. Progress in digital radiography

    International Nuclear Information System (INIS)

    Cappelle, A.

    2016-01-01

    Because of its practical aspect digital radiography is more and more used in the industrial sector. There are 2 kinds of digital radiography. First, the 'computed radiography' that uses a photon-stimulated screen, and after radiation exposure this screen must be read by an analyser to get a digit image. The second type is the 'direct radiography' that allows one to get a digit radiograph of the object directly. Digital radiography uses the same radioactive nuclides as radiography with silver films: cobalt, iridium or selenium. The spatial resolution of digital radiography is less good than with classical silver film radiography but digital radiography offers a better visual contrast. (A.C.)

  17. Search for Physics beyond the Standard Model with the ATLAS detector and the development of radiation detectors

    CERN Document Server

    Silver, Yiftah

    We are investigating a radiation detector based on plasma display panel technology, the principal component of plasma television displays. This Plasma Panel Sensor (PPS) technology is a variant of micro-pattern gas radiation detectors. Based on the properties of existing plasma display panels, we expect eventually to be able to build a sealed array of plasma discharge gas cells to detect ionizing radiation with fast rise time of less than 10ns and high spatial resolution using a pixel pitch of less than 100 micrometer. In this thesis I shall describe our program of testing plasma display panels as detectors, including simulations, design and the first laboratory and beam studies that demonstrate the detection of cosmic ray muons, beta rays and medium energy protons. The ATLAS detector is used to search for high-mass resonances, in particular heavy neutral gauge bosons (Z') and excited states of Kaluza-Klein γ/Z bosons decaying to an electron-positron pair or a muon-antimuon pair. Results are presented based ...

  18. Energy-resolved fast neutron resonance radiography at CSNS

    Science.gov (United States)

    Tan, Zhixin; Tang, Jingyu; Jing, Hantao; Fan, Ruirui; Li, Qiang; Ning, Changjun; Bao, Jie; Ruan, Xichao; Luan, Guangyuan; Feng, Changqin; Zhang, Xianpeng

    2018-05-01

    The white neutron beamline at the China Spallation Neutron Source will be used mainly for nuclear data measurements. It will be characterized by high flux and broad energy spectra. To exploit the beamline as a neutron imaging source, we propose a liquid scintillator fiber array for fast neutron resonance radiography. The fiber detector unit has a small exposed area, which will limit the event counts and separate the events in time, thus satisfying the requirements for single-event time-of-flight (SEToF) measurement. The current study addresses the physical design criteria for ToF measurement, including flux estimation and detector response. Future development and potential application of the technology are also discussed.

  19. Radiography – How do students understand the concept of radiography?

    International Nuclear Information System (INIS)

    Lundgren, S.M.; Lundén, M.; Andersson, B.T.

    2015-01-01

    Background: Radiography as a concept has mainly been associated with the functional role of the radiographer. The concept has been studied from a theoretical point of view. However, there is a lack of a theoretical foundation and research on the actual substance of the term radiography used in education. It is therefore important to undertake an investigation in order to determine how students after three years education understand the subject of radiography. Aim: The aim of this study was to analyse how students in the Swedish radiographers' degree program understand the concept of radiography. Method: A concept analysis was made according to the hybrid model, which combines theoretical, fieldwork and analytical phases. A summative content analysis was used to identify the number and content of statements. The empirical data were collected from questionnaires answered by radiography students at four universities in Sweden. Findings: All radiography students' exemplified radiography with statements related to the practical level although some of them also identified radiography at an abstract level, as a subject within a discipline. The attribute ‘An interdisciplinary area of knowledge’ emerged, which is an attribute on the abstract level. The practical level was described by four attributes: Mastering Medical Imaging’, ‘To accomplish images for diagnosis and interventions’, ‘Creating a caring environment’ and ‘Enabling fruitful encounters’. Conclusion: The hybrid model used was a versatile model of concept development. The results of this study have increased the understanding of what characterizes the concept of radiography in a Swedish context. - Highlights: • This concept analysis of radiography was undertaken according to a hybrid model. • In radiography humanistic aspects are emphasized, a shift from the technological perspective. • The attributes demonstrate the essence and interdisciplinary nature of radiography. • This

  20. Evaluation of imaging quality for flat-panel detector based low dose C-arm CT system

    International Nuclear Information System (INIS)

    Seo, Chang-Woo; Cha, Bo Kyung; Jeon, Sungchae; Huh, Young

    2015-01-01

    The image quality associated with the extent of the angle of gantry rotation, the number of projection views, and the dose of X-ray radiation was investigated in flat-panel detector (FPD) based C-arm cone-beam computed tomography (CBCT) system for medical applications. A prototype CBCT system for the projection acquisition used the X-ray tube (A-132, Varian inc.) having rhenium-tungsten molybdenum target and flat panel a-Si X-ray detector (PaxScan 4030CB, Varian inc.) having a 397 x 298 mm active area with 388 μm pixel pitch and 1024 x 768 pixels in 2 by 2 binning mode. The performance comparison of X-ray imaging quality was carried out using the Feldkamp, Davis, and Kress (FDK) reconstruction algorithm between different conditions of projection acquisition. In this work, head-and-dental (75 kVp/20 mA) and chest (90 kVp/25 mA) phantoms were used to evaluate the image quality. The 361 (30 fps x 12 s) projection data during 360 deg. gantry rotation with 1 deg. interval for the 3D reconstruction were acquired. Parke weighting function were applied to handle redundant data and improve the reconstructed image quality in a mobile C-arm system with limited rotation angles. The reconstructed 3D images were investigated for comparison of qualitative image quality in terms of scan protocols (projection views, rotation angles and exposure dose). Furthermore, the performance evaluation in image quality will be investigated regarding X-ray dose and limited projection data for a FPD based mobile C-arm CBCT system. (authors)

  1. Displacement tracking in single human trabecula with metal-plated micro-spheres using X-ray radiography imaging

    International Nuclear Information System (INIS)

    Jiroušek, O; Kytýř, D; Doktor, T; Dammer, J; Krejčí, F

    2013-01-01

    This study presents an improved radiographic method for strain measurement in very small samples of a single trabeculae. X-ray micro-radiography was used to track the deformation behaviour of individual trabecula during mechanical loading. As the X-ray micro-radiography images of a single trabecula show no significant features applicable for digital image correlation (DIC) a random pattern of markers was created on the surfaces of the samples to improve the accuracy of tracking. Metal plated borosilicate glassmicro-spheres (mean diameter 10 μm) were used as the markers for trabecular displacement tracking. Two different X-ray imaging setups were used for this purpose. The specimens of isolated trabeculae were loaded by a micro-mechanical testing device developed with respect to radiographical observation. This compact device enables a high precision three-point bending measurement. The specimen was continuously irradiated during the loading procedure by a micro-focus X-ray source. The radiographs were acquired by a single-photon counting silicon pixel detector and s flat panel sensor with CsI flipped scintillator plate. Circular Hough transform was used to locate positions of the spherical markers in the sequence of acquired radiographs and to calculate the strain in the loaded sample. The gold-coated micro-spheres provide clearly visible features in the sequence of radiographs after beam hardening correction, which in conjunction with pattern recognition algorithm enables to substantially improve the accuracy of strain measurements.

  2. Digital radiography

    International Nuclear Information System (INIS)

    Zani, M.L.

    2002-01-01

    X-ray radiography is a very common technique used to check the homogeneity of a material or the inside of a mechanical part. Generally the radiation that goes through the material to check, produced an image on a sensitized film. This method requires time because the film needs to be developed, digital radiography has no longer this inconvenient. In digital radiography the film is replaced by digital data and can be processed as any computer file. This new technique is promising but its main inconvenient is that today its resolution is not so good as that of film radiography. (A.C.)

  3. CSC large panel R ampersand D summary for the SSC GEM muon subsystem

    International Nuclear Information System (INIS)

    Pratuch, S.M.; Clements, J.W.; Spellman, G.P.

    1994-05-01

    The GEM Detector uses 1,128 Cathode Strip Chamber (CSC) muon detectors requiring a total of approximately 10,000 precision panels in the CSC assemblies. These panels must be fabricated to extreme tolerances in order to meet the physics requirement. A fabrication technique used to produce two large panels, nominally 1 by 3 meters, is described and the resulting panel precision is reported

  4. Evaluation of an image receptor for computed radiography system in mammography

    International Nuclear Information System (INIS)

    Dantas, Marcelino V.A.; Rosado, Paulo H.G.; Santana, Priscila C.; Alvarenga, Frederico L.; Nogueira, Maria S.

    2009-01-01

    In this work, the performance of an image receptor for computed radiography system, Kodak CR850, was assessed through tests, recommended by the European protocol, with a specific image plate for mammography where were analyzed the Contrast-to-noise ratio (CNR) and uniformity and linearity of detector. The CNRs were 14.1, 11.7, 10.3, 8.4, 7.1 and 5.9 for 2, 3, 4, 5, 6 and 7 cm polymethylmethacrylate (PMMA) thickness, respectively. The linearity between detector response and dose, obtained a correlation coefficient (R 2 ) greater than 0.99, and the maximum variation found in the detector uniformity calculation was 3.94 in the lower right corner. (author)

  5. Neutron radiography with sub-15 {mu}m resolution through event centroiding

    Energy Technology Data Exchange (ETDEWEB)

    Tremsin, Anton S., E-mail: ast@ssl.berkeley.edu [Space Sciences Laboratory, University of California at Berkeley, Berkeley, CA 94720 (United States); McPhate, Jason B.; Vallerga, John V.; Siegmund, Oswald H.W. [Space Sciences Laboratory, University of California at Berkeley, Berkeley, CA 94720 (United States); Bruce Feller, W. [NOVA Scientific, Inc. 10 Picker Road, Sturbridge, MA 01566 (United States); Lehmann, Eberhard; Kaestner, Anders; Boillat, Pierre; Panzner, Tobias; Filges, Uwe [Spallation Neutron Source Division, Paul Scherrer Institute, CH-5232 Villigen (Switzerland)

    2012-10-01

    Conversion of thermal and cold neutrons into a strong {approx}1 ns electron pulse with an absolute neutron detection efficiency as high as 50-70% makes detectors with {sup 10}B-doped Microchannel Plates (MCPs) very attractive for neutron radiography and microtomography applications. The subsequent signal amplification preserves the location of the event within the MCP pore (typically 6-10 {mu}m in diameter), providing the possibility to perform neutron counting with high spatial resolution. Different event centroiding techniques of the charge landing on a patterned anode enable accurate reconstruction of the neutron position, provided the charge footprints do not overlap within the time required for event processing. The new fast 2 Multiplication-Sign 2 Timepix readout with >1.2 kHz frame rates provides the unique possibility to detect neutrons with sub-15 {mu}m resolution at several MHz/cm{sup 2} counting rates. The results of high resolution neutron radiography experiments presented in this paper, demonstrate the sub-15 {mu}m resolution capability of our detection system. The high degree of collimation and cold spectrum of ICON and BOA beamlines combined with the high spatial resolution and detection efficiency of MCP-Timepix detectors are crucial for high contrast neutron radiography and microtomography with high spatial resolution. The next generation of Timepix electronics with sparsified readout should enable counting rates in excess of 10{sup 7} n/cm{sup 2}/s taking full advantage of high beam intensity of present brightest neutron imaging facilities.

  6. Pixel Detectors for Particle Physics and Imaging Applications

    CERN Document Server

    Wermes, N

    2003-01-01

    Semiconductor pixel detectors offer features for the detection of radiation which are interesting for particle physics detectors as well as for imaging e.g. in biomedical applications (radiography, autoradiography, protein crystallography) or in Xray astronomy. At the present time hybrid pixel detectors are technologically mastered to a large extent and large scale particle detectors are being built. Although the physical requirements are often quite different, imaging applications are emerging and interesting prototype results are available. Monolithic detectors, however, offer interesting features for both fields in future applications. The state of development of hybrid and monolithic pixel detectors, excluding CCDs, and their different suitability for particle detection and imaging, is reviewed.

  7. Twenty-degree-tilt radiography for evaluation of lateral humeral condylar fracture in children

    International Nuclear Information System (INIS)

    Imada, Hideaki; Tanaka, Ryuji; Itoh, Yohei; Kishi, Kazuhiko

    2010-01-01

    To investigate the efficacy of '20 -tilt anteroposterior (A-P) radiography' in the assessment of lateral condylar fractures of the distal humerus. Eighteen children with lateral humeral condylar fractures were studied. Every child underwent conventional A-P and lateral radiography, and six children underwent multi-detector computed tomography (MDCT). For the investigation of 20 -tilt radiography, ten children with lateral humeral condylar fractures had conventional and 20 -tilt A-P and lateral radiography both preoperatively and postoperatively. Fragment dislocation was measured at the lateral and medial margins of the fracture on both the conventional A-P and 20 -tilt A-P radiographs. The lateral condylar fragment was triangular and was most prominent posteriorly. The fracture line was typically tilted approximately 20 to a reference line perpendicular to the long axis of the humerus in the lateral view. The extent of dislocation at the lateral and medial margins of the fracture site by 20 -tilt A-P radiography (9.3 ± 3.6 mm and 5.6 ± 2.5 mm) was significantly wider than that measured by the conventional method (6.8 ± 4.1 mm and 2.0 ± 1.5 mm), which may influence treatment. Twenty-degree-tilt A-P radiography may more precisely demonstrate fragment dislocation than standard radiographs and may influence patient treatment. (orig.)

  8. Evidence-based radiography

    International Nuclear Information System (INIS)

    Hafslund, Bjorg; Clare, Judith; Graverholt, Birgitte; Wammen Nortvedt, Monica

    2008-01-01

    Evidence-based practice (EBP) offers the integration of the best research evidence with clinical knowledge and expertise and patient values. EBP is a well known term in health care. This paper discusses the implementation of EBP into radiography and introduces the term evidence-based radiography. Evidence-based radiography is radiography informed and based on the combination of clinical expertise and the best available research-based evidence, patient preferences and resources available. In Norway, EBP in radiography is being debated and radiographers are discussing the challenges of implementing EBP in both academic and clinical practice. This discussion paper explains why EBP needs to be a basis for a radiography curriculum and a part of radiographers' practice. We argue that Norwegian radiographers must increase participation in research and developing practice within their specific radiographic domain

  9. Diagnostic ability of panoramic radiography for mandibular fractures

    International Nuclear Information System (INIS)

    Lee, Ji Hyun; Jung, Yun Hoa; Cho Bong Hae; Hwang, Dae Seok

    2010-01-01

    The purpose of this study was to evaluate the diagnostic efficacy of panoramic radiographs for detection of mandibular fractures. The sample was comprised of 65 patients (55 fractured, 10 non-fractured) with 92 fracture sites confirmed by multi-detector computed tomography (CT). Panoramic radiographs were evaluated for mandibular fractures by six examiners; two oral and maxillofacial radiologists (observer A and B), two oral and maxillofacial surgeons (observer C and D), and two general dentists (observer E and F). Sensitivity of panoramic radiography for mandibular fractures was 95.7% in observer A and B, 93.5% in observer C and D and 80.4% in observer E and F. The lowest sensitivity was shown in symphyseal/parasymphyseal areas, followed by subcondylar/condylar regions. Panoramic radiography is adequate for detection of mandibular fractures. However, additional multidetector CT is recommended to ascertain some indecisive fractures of symphysis and condyle, and in complicated fractures.

  10. Diagnostic ability of panoramic radiography for mandibular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Hyun; Jung, Yun Hoa; Cho Bong Hae; Hwang, Dae Seok [School of Dentistry, Pusan National University, Pusan (Korea, Republic of)

    2010-03-15

    The purpose of this study was to evaluate the diagnostic efficacy of panoramic radiographs for detection of mandibular fractures. The sample was comprised of 65 patients (55 fractured, 10 non-fractured) with 92 fracture sites confirmed by multi-detector computed tomography (CT). Panoramic radiographs were evaluated for mandibular fractures by six examiners; two oral and maxillofacial radiologists (observer A and B), two oral and maxillofacial surgeons (observer C and D), and two general dentists (observer E and F). Sensitivity of panoramic radiography for mandibular fractures was 95.7% in observer A and B, 93.5% in observer C and D and 80.4% in observer E and F. The lowest sensitivity was shown in symphyseal/parasymphyseal areas, followed by subcondylar/condylar regions. Panoramic radiography is adequate for detection of mandibular fractures. However, additional multidetector CT is recommended to ascertain some indecisive fractures of symphysis and condyle, and in complicated fractures.

  11. Cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS flat panel detector: Visibility of simulated microcalcifications

    OpenAIRE

    Shen, Youtao; Zhong, Yuncheng; Lai, Chao-Jen; Wang, Tianpeng; Shaw, Chris C.

    2013-01-01

    Purpose: To measure and investigate the improvement of microcalcification (MC) visibility in cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS/CsI flat panel detector (Dexela 2923, Perkin Elmer).

  12. Experimental system for high resolution X-ray transmission radiography

    Czech Academy of Sciences Publication Activity Database

    Jakůbek, J.; Holý, T.; Jakůbek, M.; Vavřík, Daniel; Vykydal, Z.

    Volume 563, č. 1 (2006), s. 278-281 ISSN 0168-9002. [Intern. Workshop on Radiation Imaging Detectors /7./. Grenoble, 04.07.2005-07.07.2005] R&D Projects: GA MŠk(CZ) 1P04LA211; GA ČR(CZ) GA106/04/0567 Institutional research plan: CEZ:AV0Z20710524 Keywords : digital radiography * beam hardening * mikroradiography * roentgenogram quality Subject RIV: JB - Sensors, Measurment, Regulation Impact factor: 1.185, year: 2006

  13. Fast neutron radiography of extended biological and medical objects

    International Nuclear Information System (INIS)

    Duehmke, E.; Greim, L.

    1978-01-01

    The fast neutron radiography enables us to image extended objects and yields quite different pictures than conventional roentgenograms. Using foils of cellulose nitrate and the track etching technique a γ-ray-insensitive detector is available providing sufficient imaging qualities. One of the biological neutrograms shown in the paper is of special importance because one can see a malignant tumor of the columna vertebralis. This finding was not detectable by roentgenological examination. (orig.) [de

  14. A miniature X-ray tube based on carbon nanotube for an intraoral dental radiography

    International Nuclear Information System (INIS)

    Kim, Hyun Jin; Park, Han Beom; Lee, Ju Hyuk; Cho, Sung Oh

    2016-01-01

    The number of human teeth that can be radiographically taken is limited. Moreover, at least two X-ray shots are required to get images of teeth from both sides of the mouth. In order to overcome the disadvantages of conventional dental radiography, a dental radiograph has been proposed in which an X-ray tube is inserted into the mouth while an X-ray detector is placed outside the mouth. The miniature X-ray tube is required small size to insert into the mouth. Recently, we have fabricated a miniature x-ray tube with the diameter of 7 mm using a carbon nanotube (CNT) field. But, commercialized miniature X-ray tube were adopted a thermionic type using tungsten filament. The X-ray tubes adopted thermionic emission has a disadvantage of increasing temperature of x-ray tube. So it need to cooling system to cool x-ray tube. On the other hands, X-ray tubes adopted CNT field emitters don't need cooling systems because electrons are emitted from CNT by applying high voltage without heating. We have developed the miniature x-ray tube that produce x-ray with uniform spatial distribution based on carbon nanotube field emitters. The fabricated miniature x-ray tube can be stably and reliably operated at 50kV without any vacuum pump. The developed miniature X-ray tube was applied for intraoral dental radiography that employs an intra-oral CNT-based miniature X-ray tube and extra-oral X-ray detectors. An X-ray image of many teeth was successfully obtained by a single X-ray shot using the intra-oral miniature X-ray tube system. Furthermore, images of both molar teeth of pig were simultaneously obtained by a single X-ray shot. These results show that the intraoral dental radiography, which employs an intraoral miniature X-ray tube and an extraoral X-ray detector, performs better than conventional dental radiography

  15. A miniature X-ray tube based on carbon nanotube for an intraoral dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jin; Park, Han Beom; Lee, Ju Hyuk; Cho, Sung Oh [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    The number of human teeth that can be radiographically taken is limited. Moreover, at least two X-ray shots are required to get images of teeth from both sides of the mouth. In order to overcome the disadvantages of conventional dental radiography, a dental radiograph has been proposed in which an X-ray tube is inserted into the mouth while an X-ray detector is placed outside the mouth. The miniature X-ray tube is required small size to insert into the mouth. Recently, we have fabricated a miniature x-ray tube with the diameter of 7 mm using a carbon nanotube (CNT) field. But, commercialized miniature X-ray tube were adopted a thermionic type using tungsten filament. The X-ray tubes adopted thermionic emission has a disadvantage of increasing temperature of x-ray tube. So it need to cooling system to cool x-ray tube. On the other hands, X-ray tubes adopted CNT field emitters don't need cooling systems because electrons are emitted from CNT by applying high voltage without heating. We have developed the miniature x-ray tube that produce x-ray with uniform spatial distribution based on carbon nanotube field emitters. The fabricated miniature x-ray tube can be stably and reliably operated at 50kV without any vacuum pump. The developed miniature X-ray tube was applied for intraoral dental radiography that employs an intra-oral CNT-based miniature X-ray tube and extra-oral X-ray detectors. An X-ray image of many teeth was successfully obtained by a single X-ray shot using the intra-oral miniature X-ray tube system. Furthermore, images of both molar teeth of pig were simultaneously obtained by a single X-ray shot. These results show that the intraoral dental radiography, which employs an intraoral miniature X-ray tube and an extraoral X-ray detector, performs better than conventional dental radiography.

  16. Simulations of Liners and Test Objects for a New Atlas Advanced Radiography Source

    International Nuclear Information System (INIS)

    Morgan, D. V.; Iversen, S.; Hilko, R. A.

    2002-01-01

    The Advanced Radiographic Source (ARS) will improve the data significantly due to its smaller source width. Because of the enhanced ARS output, larger source-to-object distances are a reality. The harder ARS source will allow radiography of thick high-Z targets. The five different spectral simulations resulted in similar imaging detector weighted transmission. This work used a limited set of test objects and imaging detectors. Other test objects and imaging detectors could possibly change the MVp-sensitivity result. The effect of material motion blur must be considered for the ARS due to the expected smaller X-ray source size. This study supports the original 1.5-MVp value

  17. An experimental comparative study of radiography, ultrasonography and CT imaging in the IV catheter fragment

    International Nuclear Information System (INIS)

    Kweon, Dae Cheol

    2016-01-01

    The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon® IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose (0.2139 mSv·Gy-1·cm-2) form DAP DAP (0.93 μGy·m2 ), and dose length product (DLP) (201 mGy·cm) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography

  18. The design and imaging characteristics of dynamic, solid-state, flat-panel x-ray image detectors for digital fluoroscopy and fluorography

    International Nuclear Information System (INIS)

    Cowen, A.R.; Davies, A.G.; Sivananthan, M.U.

    2008-01-01

    Dynamic, flat-panel, solid-state, x-ray image detectors for use in digital fluoroscopy and fluorography emerged at the turn of the millennium. This new generation of dynamic detectors utilize a thin layer of x-ray absorptive material superimposed upon an electronic active matrix array fabricated in a film of hydrogenated amorphous silicon (a-Si:H). Dynamic solid-state detectors come in two basic designs, the indirect-conversion (x-ray scintillator based) and the direct-conversion (x-ray photoconductor based). This review explains the underlying principles and enabling technologies associated with these detector designs, and evaluates their physical imaging characteristics, comparing their performance against the long established x-ray image intensifier television (TV) system. Solid-state detectors afford a number of physical imaging benefits compared with the latter. These include zero geometrical distortion and vignetting, immunity from blooming at exposure highlights and negligible contrast loss (due to internal scatter). They also exhibit a wider dynamic range and maintain higher spatial resolution when imaging over larger fields of view. The detective quantum efficiency of indirect-conversion, dynamic, solid-state detectors is superior to that of both x-ray image intensifier TV systems and direct-conversion detectors. Dynamic solid-state detectors are playing a burgeoning role in fluoroscopy-guided diagnosis and intervention, leading to the displacement of x-ray image intensifier TV-based systems. Future trends in dynamic, solid-state, digital fluoroscopy detectors are also briefly considered. These include the growth in associated three-dimensional (3D) visualization techniques and potential improvements in dynamic detector design

  19. Scintillating ribbon x-ray detector

    International Nuclear Information System (INIS)

    Kinchen, B.E.; Rogers, A.

    1995-01-01

    A patent in the early 1970's by Aerojet Corporation in Sacramento, CA put forth the idea of using an array of scintillating fibers for x-ray detection and imaging. In about 1975, Pratt and Whitney Aircraft in East Hartford, CT designed and manufactured an imaging system based on the patent. The device was 1.75 in thick in the direction of the x-ray beam and about 4 in. by 4 in. square. The device was used with a 8 MeV x-ray source to image and measure internal clearances within operating aircraft, gas turbines engines. There are significant advantages of fiber optic detectors in x-ray detection. However, the advantages are often outweighed by the disadvantages. Two of the advantages of scintillating fiber optic x-ray detectors are: (1) high limiting spatial frequency -- between 20 and 25 lp/mm; and (2) excellent x-ray stopping power -- they can be made thick and retain spatial resolution. In traditional fiber optic detectors the x-rays are oriented parallel to the long axis of the fiber. For the scintillating ribbon x-ray sensor, the x-rays are oriented normal to the fiber long axis. This ribbon sensor technique has a number of advantages over the two current radiographic techniques digital x-radiography and x-ray film: The main advantage the ribbon has is size and shape. It can be as thin as 0.05 in., virtually any width or length, and flexible. Once positioned in a given location, 20 to 100 square inches of the object being inspected can be imaged with a single x-ray beam sweep. It is clear that conventional digital cameras do not lend themselves to placement between walls of aircraft structures or similar items requiring x-ray inspections. A prototype scintillating ribbon x-ray sensor has been fabricated and tested by Synergistic Detector Designs. Images were acquired on corrosion test panels of aluminum fabricated by Iowa State University

  20. Whole body dual X-ray absorptiometry for bone mineral density and body composition using a flat panel detector

    International Nuclear Information System (INIS)

    Dinten, J.M.; Robert-Coutant, C.; Gonon, G.; Bordy, T.

    2003-01-01

    Whole-body dual-energy X-ray absorptiometry (DXA) systems are used for the determination of bone mineral density (BMD) but also for body composition estimates (lean mass and fat mass). The calculation is based on the difference in attenuation of body tissues for a low-energy of about 50 KeV and a high-energy of about 80-100 KeV. The measurement of dual-energy projections allows first to compute to the body composition in the non-bone area, and then to extrapolate the fat / lean ratio of soft tissue into the bone area in order to compute the BMD. Since detectors have limited area, a whole body examination requires a scan of the patient and a reconstruction process in order to build up a large field image from smaller radiographs. This reconstruction process must keep the quantitative value of the radiographs, and avoid any distortion which could be a consequence of the conic acquisition geometry. The cone angle is low (6 at maximum) and the large overlap between radiographs helps to reconstruct an image equivalent with a parallel-beam geometry. Scatter is corrected from the radiographs before reconstruction, as described in a previous paper ('Dual-energy X-rays absorptiometry using a 2D digital radiography detector. Application to bone densitometry', SPIE Medical Imaging 2001, Medical Physics). We have developed an original reconstruction method dedicated to whole-body examinations which will be described. Thanks to the quasi-radiologic quality of the detector, reconstructed images are of very good quality and this makes the measurement of BMD and fat / lean masses easier. (author)

  1. X-ray backscatter imaging for radiography by selective detection and snapshot: Evolution, development, and optimization

    Science.gov (United States)

    Shedlock, Daniel

    Compton backscatter imaging (CBI) is a single-sided imaging technique that uses the penetrating power of radiation and unique interaction properties of radiation with matter to image subsurface features. CBI has a variety of applications that include non-destructive interrogation, medical imaging, security and military applications. Radiography by selective detection (RSD), lateral migration radiography (LMR) and shadow aperture backscatter radiography (SABR) are different CBI techniques that are being optimized and developed. Radiography by selective detection (RSD) is a pencil beam Compton backscatter imaging technique that falls between highly collimated and uncollimated techniques. Radiography by selective detection uses a combination of single- and multiple-scatter photons from a projected area below a collimation plane to generate an image. As a result, the image has a combination of first- and multiple-scatter components. RSD techniques offer greater subsurface resolution than uncollimated techniques, at speeds at least an order of magnitude faster than highly collimated techniques. RSD scanning systems have evolved from a prototype into near market-ready scanning devices for use in a variety of single-sided imaging applications. The design has changed to incorporate state-of-the-art detectors and electronics optimized for backscatter imaging with an emphasis on versatility, efficiency and speed. The RSD system has become more stable, about 4 times faster, and 60% lighter while maintaining or improving image quality and contrast over the past 3 years. A new snapshot backscatter radiography (SBR) CBI technique, shadow aperture backscatter radiography (SABR), has been developed from concept and proof-of-principle to a functional laboratory prototype. SABR radiography uses digital detection media and shaded aperture configurations to generate near-surface Compton backscatter images without scanning, similar to how transmission radiographs are taken. Finally, a

  2. AXIS: An instrument for imaging Compton radiographs using the Advanced Radiography Capability on the NIF

    Energy Technology Data Exchange (ETDEWEB)

    Hall, G. N., E-mail: hall98@llnl.gov; Izumi, N.; Tommasini, R.; Carpenter, A. C.; Palmer, N. E.; Zacharias, R.; Felker, B.; Holder, J. P.; Allen, F. V.; Bell, P. M.; Bradley, D.; Montesanti, R.; Landen, O. L. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States)

    2014-11-15

    Compton radiography is an important diagnostic for Inertial Confinement Fusion (ICF), as it provides a means to measure the density and asymmetries of the DT fuel in an ICF capsule near the time of peak compression. The AXIS instrument (ARC (Advanced Radiography Capability) X-ray Imaging System) is a gated detector in development for the National Ignition Facility (NIF), and will initially be capable of recording two Compton radiographs during a single NIF shot. The principal reason for the development of AXIS is the requirement for significantly improved detection quantum efficiency (DQE) at high x-ray energies. AXIS will be the detector for Compton radiography driven by the ARC laser, which will be used to produce Bremsstrahlung X-ray backlighter sources over the range of 50 keV–200 keV for this purpose. It is expected that AXIS will be capable of recording these high-energy x-rays with a DQE several times greater than other X-ray cameras at NIF, as well as providing a much larger field of view of the imploded capsule. AXIS will therefore provide an image with larger signal-to-noise that will allow the density and distribution of the compressed DT fuel to be measured with significantly greater accuracy as ICF experiments are tuned for ignition.

  3. AXIS: an instrument for imaging Compton radiographs using the Advanced Radiography Capability on the NIF.

    Science.gov (United States)

    Hall, G N; Izumi, N; Tommasini, R; Carpenter, A C; Palmer, N E; Zacharias, R; Felker, B; Holder, J P; Allen, F V; Bell, P M; Bradley, D; Montesanti, R; Landen, O L

    2014-11-01

    Compton radiography is an important diagnostic for Inertial Confinement Fusion (ICF), as it provides a means to measure the density and asymmetries of the DT fuel in an ICF capsule near the time of peak compression. The AXIS instrument (ARC (Advanced Radiography Capability) X-ray Imaging System) is a gated detector in development for the National Ignition Facility (NIF), and will initially be capable of recording two Compton radiographs during a single NIF shot. The principal reason for the development of AXIS is the requirement for significantly improved detection quantum efficiency (DQE) at high x-ray energies. AXIS will be the detector for Compton radiography driven by the ARC laser, which will be used to produce Bremsstrahlung X-ray backlighter sources over the range of 50 keV-200 keV for this purpose. It is expected that AXIS will be capable of recording these high-energy x-rays with a DQE several times greater than other X-ray cameras at NIF, as well as providing a much larger field of view of the imploded capsule. AXIS will therefore provide an image with larger signal-to-noise that will allow the density and distribution of the compressed DT fuel to be measured with significantly greater accuracy as ICF experiments are tuned for ignition.

  4. Source strength verification and quality assurance of preloaded brachytherapy needles using a CMOS flat panel detector

    Energy Technology Data Exchange (ETDEWEB)

    Golshan, Maryam, E-mail: maryam.golshan@bccancer.bc.ca [Department of Physics, University of British Columbia, Vancouver, British Columbia V6T1Z1, Canada and Department of Medical Physics, Vancouver Center, British Columbia Cancer Agency, Vancouver, British Columbia V5Z 4E6 (Canada); Spadinger, Ingrid [Department of Medical Physics, Vancouver Center, British Columbia Cancer Agency, Vancouver, British Columbia V5Z 4E6 (Canada); Chng, Nick [Department of Medical Physics, Center for the North, British Columbia Cancer Agency, Prince George, British Columbia V2M 7E9 (Canada)

    2016-06-15

    Purpose: Current methods of low dose rate brachytherapy source strength verification for sources preloaded into needles consist of either assaying a small number of seeds from a separate sample belonging to the same lot used to load the needles or performing batch assays of a subset of the preloaded seed trains. Both of these methods are cumbersome and have the limitations inherent to sampling. The purpose of this work was to investigate an alternative approach that uses an image-based, autoradiographic system capable of the rapid and complete assay of all sources without compromising sterility. Methods: The system consists of a flat panel image detector, an autoclavable needle holder, and software to analyze the detected signals. The needle holder was designed to maintain a fixed vertical spacing between the needles and the image detector, and to collimate the emissions from each seed. It also provides a sterile barrier between the needles and the imager. The image detector has a sufficiently large image capture area to allow several needles to be analyzed simultaneously.Several tests were performed to assess the accuracy and reproducibility of source strengths obtained using this system. Three different seed models (Oncura 6711 and 9011 {sup 125}I seeds, and IsoAid Advantage {sup 103}Pd seeds) were used in the evaluations. Seeds were loaded into trains with at least 1 cm spacing. Results: Using our system, it was possible to obtain linear calibration curves with coverage factor k = 1 prediction intervals of less than ±2% near the centre of their range for the three source models. The uncertainty budget calculated from a combination of type A and type B estimates of potential sources of error was somewhat larger, yielding (k = 1) combined uncertainties for individual seed readings of 6.2% for {sup 125}I 6711 seeds, 4.7% for {sup 125}I 9011 seeds, and 11.0% for Advantage {sup 103}Pd seeds. Conclusions: This study showed that a flat panel detector dosimetry system

  5. Digital luminescent radiography: A substitute for conventional chest radiography?

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Krug, B.; Lorenz, R.; Steinbrich, W.

    1990-01-01

    The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a consequence, DLR is presently not in a position to replace traditional film-screen radiography of the chest completely. (orig.) [de

  6. Characterization of a gamma-ray source based on a laser-plasma accelerator with applications to radiography

    International Nuclear Information System (INIS)

    Edwards, R.D.; Sinclair, M.A.; Goldsack, T.J.; Krushelnick, K.; Beg, F.N.; Clark, E.L.; Dangor, A.E.; Najmudin, Z.; Tatarakis, M.; Walton, B.; Zepf, M.; Ledingham, K.W.D.; Spencer, I.; Norreys, P.A.; Clarke, R.J.; Kodama, R.; Toyama, Y.; Tampo, M.

    2002-01-01

    The application of high intensity laser-produced gamma rays is discussed with regard to picosecond resolution deep-penetration radiography. The spectrum and angular distribution of these gamma rays is measured using an array of thermoluminescent detectors for both an underdense (gas) target and an overdense (solid) target. It is found that the use of an underdense target in a laser plasma accelerator configuration produces a much more intense and directional source. The peak dose is also increased significantly. Radiography is demonstrated in these experiments and the source size is also estimated

  7. Thorium-uranium fission radiography

    Science.gov (United States)

    Haines, E. L.; Weiss, J. R.; Burnett, D. S.; Woolum, D. S.

    1976-01-01

    Results are described for studies designed to develop routine methods for in-situ measurement of the abundance of Th and U on a microscale in heterogeneous samples, especially rocks, using the secondary high-energy neutron flux developed when the 650 MeV proton beam of an accelerator is stopped in a 42 x 42 cm diam Cu cylinder. Irradiations were performed at three different locations in a rabbit tube in the beam stop area, and thick metal foils of Bi, Th, and natural U as well as polished silicate glasses of known U and Th contents were used as targets and were placed in contact with mica which served as a fission track detector. In many cases both bare and Cd-covered detectors were exposed. The exposed mica samples were etched in 48% HF and the fission tracks counted by conventional transmitted light microscopy. Relative fission cross sections are examined, along with absolute Th track production rates, interaction tracks, and a comparison of measured and calculated fission rates. The practicality of fast neutron radiography revealed by experiments to data is discussed primarily for Th/U measurements, and mixtures of other fissionable nuclei are briefly considered.

  8. High-energy test of proton radiography concepts

    International Nuclear Information System (INIS)

    Amann, J.F.; Atencio, L.G.; Espinoza, C.J.

    1997-01-01

    This is the final report of a one-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The goal of this work was to demonstrate the use of high energy protons to produce radiographs of heavy metal test objects. The authors executed a proof-of-principle experiment using GeV proton beams available at the Brookhaven National Laboratory Alternating Gradient Synchrotron (AGS). The experiment produced proton radiographs of a suitably dense, unclassified test object. The experiment tested capabilities in data collection, image reconstruction, and hydro-code simulation and validated models of high-energy proton radiography. A lens was designed using existing quadrupole magnets, constructed on the A1 beam line of the AGS and used to image 10-GeV protons. The results include: (1) images made with an integrating detector, (2) measurements of the background and measurements of the resolution functions, and (3) forward model fits to the transmission data. In all cases the results agree with initial estimates and provide strong support for the utility of proton radiography as a new hydrotest diagnostic

  9. Charged Particle Radiography

    International Nuclear Information System (INIS)

    Morris, Chris

    2004-01-01

    The Coulomb multiple scattering of charged particles as they pass through material allows them to be used as a radiographic probe. This forms the basis for a new kind of radiography that is finding application where conventional x-ray radiography is limited by flux or backgrounds. Charged-particle radiography is providing a versatile new probe that has advantages over conventional x-ray radiography for some unique application. Proton radiography has been used to make quantitative motion pictures of high explosive driven experiments and proves to be of great value for radiographing experiments that mock up nuclear weapon primaries for stockpile certification. By taking advantage of magnetic lens to magnify images and by using the very bright beams that can be made with electrons, charged-particle radiography may be useful for studying the fine spatial detail and very fast motion in laser driven implosion experiments at the National Ignition Facility. Finally, radiographs can be made using cosmic-ray muons for searching vehicles and cargo containers for surreptitious cargo of high z materials such as uranium or plutonium.

  10. Industrial radiography

    International Nuclear Information System (INIS)

    1992-01-01

    Industrial radiography is a non-destructive testing (NDT) method which allows components to be examined for flaws without interfering with their usefulness. It is one of a number of inspection methods which are commonly used in industry to control the quality of manufactured products and to monitor their performance in service. Because of its involvement in organizing training courses in all the common NDT methods in regional projects in Asia and the Pacific and Latin America and the Caribbean and in many country programmes, the Agency is aware of the importance of standardizing as far as possible the syllabi and training course notes used by the many experts who are involved in presenting the training courses. IAEA-TECDOC-628 ''Training Guidelines in Non-destructive Testing'' presents syllabi which were developed by an Agency executed UNDP project in Latin America and the Caribbean taking into account the developmental work done by the International Committee for Non-destructive Testing. Experience gained from using the radiography syllabi from TECDOC-628 at national and regional radiography training courses in the Agency executed UNDP project in Asia and the Pacific (RAS/86/073) showed that some guidance needed to be given to radiography experts engaged in teaching at these courses on the material which should be covered. The IAEA/UNDP Asia and Pacific Project National NDT Coordinators therefore undertook to prepare Radiography Training Course Notes which could be used by experts to prepare lectures for Level 1,2 and 3 radiography personnel. The notes have been expanded to cover most topics in a more complete manner than that possible at a Level 1, 2 or 3 training course and can now be used as source material for NDT personnel interested in expanding their knowledge of radiography. Refs, figs and tabs

  11. Detectors in Medicine and Biology: Applications of Detectors in Technology, Medicine and Other Fields

    CERN Document Server

    Lecoq, P

    2011-01-01

    Detectors in Medicine and Biology in 'Applications of Detectors in Technology, Medicine and Other Fields', part of 'Landolt-Börnstein - Group I Elementary Particles, Nuclei and Atoms: Numerical Data and Functional Relationships in Science and Technology, Volume 21B2: Detectors for Particles and Radiation. Part 2: Systems and Applications'. This document is part of Part 2 'Principles and Methods' of Subvolume B 'Detectors for Particles and Radiation' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the Section '7.1 Detectors in Medicine and Biology' of Chapter '7 Applications of Detectors in Technology; Medicine and Other Fields' with the content: 7.1 Detectors in Medicine and Biology 7.1.1 Dosimetry and medical imaging 7.1.1.1 Radiotherapy and dosimetry 7.1.1.2 Status of medical imaging 7.1.1.3 Towards in-vivo molecular imaging 7.1.2 X-Ray radiography and computed tomography (CT) 7.1.2.1 Different X-Ray imaging modalities 7.1.2.2 Detec...

  12. Review of medical radiography and tomography with proton beams

    Science.gov (United States)

    Johnson, Robert P.

    2018-01-01

    The use of hadron beams, especially proton beams, in cancer radiotherapy has expanded rapidly in the past two decades. To fully realize the advantages of hadron therapy over traditional x-ray and gamma-ray therapy requires accurate positioning of the Bragg peak throughout the tumor being treated. A half century ago, suggestions had already been made to use protons themselves to develop images of tumors and surrounding tissue, to be used for treatment planning. The recent global expansion of hadron therapy, coupled with modern advances in computation and particle detection, has led several collaborations around the world to develop prototype detector systems and associated reconstruction codes for proton computed tomography (pCT), as well as more simple proton radiography, with the ultimate intent to use such systems in clinical treatment planning and verification. Recent imaging results of phantoms in hospital proton beams are encouraging, but many technical and programmatic challenges remain to be overcome before pCT scanners will be introduced into clinics. This review introduces hadron therapy and the perceived advantages of pCT and proton radiography for treatment planning, reviews its historical development, and discusses the physics related to proton imaging, the associated experimental and computation issues, the technologies used to attack the problem, contemporary efforts in detector and computational development, and the current status and outlook.

  13. Digital radiography: study of an alternative technique to conventional radiography

    International Nuclear Information System (INIS)

    Banchet, J.; Tisseur, D.; Thomas, A.

    2009-01-01

    Digital radiography, already in use in many industrial applications, appears as a potential alternative technique to conventional radiography in the nuclear field (and more especially to the inspection of welded joints). The advantages of digital radiography are a reduced explosion risk (due to the use of lower energy and activity sources), a lower installation time, a reduced exclusion zone, and the absence of effluents. However, to the contrary of the US case, this technique may not be used in France as it is not referenced in the regulating codes (RCCM, etc.). Areva has launched a R and D study in order to characterize the equivalencies between digital and conventional radiography. First results of this study are given

  14. Neutron radiography, techniques and applications

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1987-10-01

    After describing the principles of the ''in pool'' and ''dry'' installations, techniques used in neutron radiography are reviewed. Use of converter foils with silver halide films for the direct and transfer methods is described. Advantages of the use of nitrocellulose film for radiographying radioactive objects are discussed. Dynamic imaging is shortly reviewed. Standardization in the field of neutron radiography (ASTM and Euratom Neutron Radiography Working Group) is described. The paper reviews main fields of use of neutron radiography. Possibilities of use of neutron radiography at research reactors in various scientific, industrial and other fields are mentioned. Examples are given of application of neutron radiography in industry and the nuclear field. (author)

  15. Basic principles of industrial radiography

    International Nuclear Information System (INIS)

    Bestbier, P.

    1983-01-01

    X-ray radiography and gamma radiography are used in industrial radiography. X-rays and gamma rays have the ability to penetrate materials and be absorbed by different densities. This characteristic makes them useful tools in industrial and medical radiography. The sources used for the generation of x-rays, gamma rays and radioisotopes are discussed. Films are one of the recording methods of x-radiography. The article also deals with advantages and disadvantages of radiography. Factors governing radiation exposure includes: the type of radiation source, material to be radiographed, distance, film, and the method for development. International specifications are also responsible for strict control over the standard of workmanship in industrial radiography

  16. Specific radiography technique

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Beside radiography testing using x-ray machine and gamma source, there are several technique that developed specifically to complete the testing that cannot be done with the two earlier. This technique was specific based on several factor, for the example, the advantages of neutron and electron using to show the image was unique compare to x-ray and gamma. Besides that, these special radiography techniques maybe differ in how to detect the radiation get through the object. These technique can used to inspect thin or specimen that contained radioactive material. There are several technique will discussed in this chapter such as neutron radiography, electron radiography, fluoroscopy and also autoradiography.

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  19. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  20. Impact of Digital Imaging on Radiation Doses to the Patient During X-ray Examination of the Urinary Tract

    International Nuclear Information System (INIS)

    Sjoeholm, B.; Geijer, H.; Persliden, J.

    2005-01-01

    Purpose: To compare radiation doses given to patients undergoing IVU (intravenous urography) before and after digitalization of our X-ray department. Material and Methods: IVU examinations were monitored with dose area product meters before and after the X-ray department changed to digital techniques. The first step was a change from film-screen to storage phosphor plates, while the second step involved changing to a flat panel detector. Forty-two patients were included for the film-screen situation, 69 when using the storage phosphor plates, and 70 using the flat panel detector. Results: A dose reduction from 41.8 Gycm 2 to 31.5 Gycm 2 was achieved with the first step when the film-screen system was replaced with storage phosphor plates. A further reduction to 12.1 Gycm 2 was achieved using the flat panel detector. Conclusion: The introduction of the flat panel detectors made a considerable dose reduction possible Digital radiography, dosimetry, urinary

  1. Impact of Digital Imaging on Radiation Doses to the Patient During X-ray Examination of the Urinary Tract

    Energy Technology Data Exchange (ETDEWEB)

    Sjoeholm, B. [Oerebro Univ. Hospital (Sweden). Depts. of Medical Physics and Radiology; Geijer, H. [Oerebro Univ. (Sweden). Dept. of Physics; Persliden, J. [Linkoeping Univ. (Sweden). Dept. of Radiation Physics

    2005-10-01

    Purpose: To compare radiation doses given to patients undergoing IVU (intravenous urography) before and after digitalization of our X-ray department. Material and Methods: IVU examinations were monitored with dose area product meters before and after the X-ray department changed to digital techniques. The first step was a change from film-screen to storage phosphor plates, while the second step involved changing to a flat panel detector. Forty-two patients were included for the film-screen situation, 69 when using the storage phosphor plates, and 70 using the flat panel detector. Results: A dose reduction from 41.8 Gycm{sup 2} to 31.5 Gycm{sup 2} was achieved with the first step when the film-screen system was replaced with storage phosphor plates. A further reduction to 12.1 Gycm{sup 2} was achieved using the flat panel detector. Conclusion: The introduction of the flat panel detectors made a considerable dose reduction possible Digital radiography, dosimetry, urinary.

  2. Digital radiography

    International Nuclear Information System (INIS)

    Kusano, Shoichi

    1993-01-01

    Firstly, from an historic point of view, fundamental concepts on digital imaging were reviewed to provide a foundation for discussion of digital radiography. Secondly, this review summarized the results of ongoing research in computed radiography that replaces the conventional film-screen system with a photo-stimulable phosphor plate; and thirdly, image quality, radiation protection, and image processing techniques were discussed with emphasis on picture archiving and communication system environment as our final goal. Finally, future expansion of digital radiography was described based on the present utilization of computed tomography at the National Defense Medical College Hospital. (author) 60 refs

  3. Radiography - A conceptual approach

    Energy Technology Data Exchange (ETDEWEB)

    Ahonen, Sanna-Mari [Department of Nursing Science and Health Administration, University of Oulu, P.O. Box 5000, FIN-90014 (Finland)], E-mail: sanna-mari.ahonen@oulu.fi

    2008-11-15

    Aim: The purpose of this article is to describe interdisciplinary comparison of the attributes of the concept of radiography in health sciences, physics and technology on the grounds of concept analysis. Background: The concept of radiography is widely used in health sciences, physics and technology. However, the content of the concept may vary. In order to clarify the concept of radiography, the concept must be systematically examined and defined in linguistic form. Method: The concept of radiography was analysed by using the evolutionary method of concept analysis. The data were collected through discretionary sampling and consisted of literature and Internet pages. Qualitative content analysis was employed for analysing the data. Findings: As a result of concept analysis, the concept of radiography in health sciences was determined as expertise of radiographers in the use of radiation, which is dual, dynamic, social and situation-related in nature, and typically based on versatile synthesis. Regarding the attributes identified, the concept of radiography has both similarities and differences between health sciences, physics and technology. Conclusions: The concept of radiography was found to be more abstract, wider, more complex and more radiographer-centred in health sciences than in other disciplines. The content of the concept of radiography seems to vary according to the discipline.

  4. Radiography - A conceptual approach

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari

    2008-01-01

    Aim: The purpose of this article is to describe interdisciplinary comparison of the attributes of the concept of radiography in health sciences, physics and technology on the grounds of concept analysis. Background: The concept of radiography is widely used in health sciences, physics and technology. However, the content of the concept may vary. In order to clarify the concept of radiography, the concept must be systematically examined and defined in linguistic form. Method: The concept of radiography was analysed by using the evolutionary method of concept analysis. The data were collected through discretionary sampling and consisted of literature and Internet pages. Qualitative content analysis was employed for analysing the data. Findings: As a result of concept analysis, the concept of radiography in health sciences was determined as expertise of radiographers in the use of radiation, which is dual, dynamic, social and situation-related in nature, and typically based on versatile synthesis. Regarding the attributes identified, the concept of radiography has both similarities and differences between health sciences, physics and technology. Conclusions: The concept of radiography was found to be more abstract, wider, more complex and more radiographer-centred in health sciences than in other disciplines. The content of the concept of radiography seems to vary according to the discipline

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  6. Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: Preliminary phantom study

    International Nuclear Information System (INIS)

    Ning Ruola; Tang Xiangyang; Conover, David; Yu Rongfeng

    2003-01-01

    Cone beam computed tomography (CBCT) has been investigated in the past two decades due to its potential advantages over a fan beam CT. These advantages include (a) great improvement in data acquisition efficiency, spatial resolution, and spatial resolution uniformity, (b) substantially better utilization of x-ray photons generated by the x-ray tube compared to a fan beam CT, and (c) significant advancement in clinical three-dimensional (3D) CT applications. However, most studies of CBCT in the past are focused on cone beam data acquisition theories and reconstruction algorithms. The recent development of x-ray flat panel detectors (FPD) has made CBCT imaging feasible and practical. This paper reports a newly built flat panel detector-based CBCT prototype scanner and presents the results of the preliminary evaluation of the prototype through a phantom study. The prototype consisted of an x-ray tube, a flat panel detector, a GE 8800 CT gantry, a patient table and a computer system. The prototype was constructed by modifying a GE 8800 CT gantry such that both a single-circle cone beam acquisition orbit and a circle-plus-two-arcs orbit can be achieved. With a circle-plus-two-arcs orbit, a complete set of cone beam projection data can be obtained, consisting of a set of circle projections and a set of arc projections. Using the prototype scanner, the set of circle projections were acquired by rotating the x-ray tube and the FPD together on the gantry, and the set of arc projections were obtained by tilting the gantry while the x-ray tube and detector were at the 12 and 6 o'clock positions, respectively. A filtered backprojection exact cone beam reconstruction algorithm based on a circle-plus-two-arcs orbit was used for cone beam reconstruction from both the circle and arc projections. The system was first characterized in terms of the linearity and dynamic range of the detector. Then the uniformity, spatial resolution and low contrast resolution were assessed using

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  8. Noise, sampling, and the number of projections in cone-beam CT with a flat-panel detector

    International Nuclear Information System (INIS)

    Zhao, Z.; Gang, G. J.; Siewerdsen, J. H.

    2014-01-01

    Purpose: To investigate the effect of the number of projection views on image noise in cone-beam CT (CBCT) with a flat-panel detector. Methods: This fairly fundamental consideration in CBCT system design and operation was addressed experimentally (using a phantom presenting a uniform medium as well as statistically motivated “clutter”) and theoretically (using a cascaded systems model describing CBCT noise) to elucidate the contributing factors of quantum noise (σ Q ), electronic noise (σ E ), and view aliasing (σ view ). Analysis included investigation of the noise, noise-power spectrum, and modulation transfer function as a function of the number of projections (N proj ), dose (D tot ), and voxel size (b vox ). Results: The results reveal a nonmonotonic relationship between image noise andN proj at fixed total dose: for the CBCT system considered, noise decreased with increasing N proj due to reduction of view sampling effects in the regime N proj proj due to increased electronic noise. View sampling effects were shown to depend on the heterogeneity of the object in a direct analytical relationship to power-law anatomical clutter of the form κ/f  β —and a general model of individual noise components (σ Q , σ E , and σ view ) demonstrated agreement with measurements over a broad range in N proj , D tot , and b vox . Conclusions: The work elucidates fairly basic elements of CBCT noise in a manner that demonstrates the role of distinct noise components (viz., quantum, electronic, and view sampling noise). For configurations fairly typical of CBCT with a flat-panel detector (FPD), the analysis reveals a “sweet spot” (i.e., minimum noise) in the rangeN proj ∼ 250–350, nearly an order of magnitude lower in N proj than typical of multidetector CT, owing to the relatively high electronic noise in FPDs. The analysis explicitly relates view aliasing and quantum noise in a manner that includes aspects of the object (“clutter”) and imaging chain

  9. Gamma radiography and its technological application

    International Nuclear Information System (INIS)

    Courtois, G.

    1962-01-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  10. Development of high quantum efficiency, flat panel, thick detectors for megavoltage x-ray imaging: An experimental study of a single-pixel prototype

    International Nuclear Information System (INIS)

    Mei, X.; Pang, G.

    2005-01-01

    Our overall goal is to develop a new generation of electronic portal imaging devices (EPIDs) with a quantum efficiency (QE) more than an order of magnitude higher and a spatial resolution equivalent to that of EPIDs currently used for portal imaging. A novel design of such a high QE flat-panel based EPID was introduced recently and its feasibility was investigated theoretically [see Pang and Rowlands, Med. Phys. 31, 3004 (2004)]. In this work, we constructed a prototype single-pixel detector based on the novel design. Some fundamental imaging properties including the QE, spatial resolution, and sensitivity of the prototype detector were measured with a 6 MV beam. It has been shown that the experimental results agree well with theoretical predictions and further development based on the novel design including the construction of a prototype area detector is warranted

  11. International Neutron Radiography Newsletter

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    At the First World Conference on Neutron Radiography i t was decided to continue the "Neutron Radiography Newsletter", published previously by J.P. Barton, as the "International Neutron Radiography Newsletter" (INRNL), with J.C. Doraanus as editor. The British Journal of Non-Destructive Testing...

  12. A comparison of digital mammography detectors and emerging technology

    International Nuclear Information System (INIS)

    Diffey, J.L.

    2015-01-01

    The overall diagnostic accuracy of digital mammography in the context of screening has been shown to be similar or slightly better than screen-film mammography. However, digital mammography encompasses both Computed Radiography (CR) and integrated Digital Radiography (DR) and there is increasing evidence to suggest that differences in detector technology are associated with variations in cancer detection rate, dose and image quality. These differences are examined in detail. Although digital mammography offers many advantages compared to screen-film, there are still some limitations with its use as a screening tool and reduced cancer detection in dense breasts remains an issue. Digital mammography detectors have paved the way for emerging technologies which may offer improvements. Taking the definition of mammography to only include X-ray imaging of the breast, this article focuses on tomosynthesis, contrast-enhanced digital mammography, stereoscopic mammography and dedicated breast computed tomography. Advanced software applications such as Computed Aided Detection (CAD) and quantitative breast density assessment are also presented. The benefits and limitations of each technique are discussed. - Highlights: • Digital detector technology affects cancer detection rate, dose and image quality. • Digital detectors have facilitated new technologies such as tomosynthesis. • 3-D techniques reduce superimposition and increase cancer detection in dense breasts. • Contrast-enhanced mammography demonstrates improved sensitivity and specificity.

  13. Qualitative discussion of quantitative radiography

    International Nuclear Information System (INIS)

    Berger, H.; Motz, J.W.

    1975-01-01

    Since radiography yields an image that can be easily related to the tested object, it is superior to many nondestructive testing techniques in revealing the size, shape, and location of certain types of discontinuities. The discussion is limited to a description of the radiographic process, examination of some of the quantitative aspects of radiography, and an outline of some of the new ideas emerging in radiography. The advantages of monoenergetic x-ray radiography and neutron radiography are noted

  14. Fast and epithermal neutron radiography using neutron irradiator

    International Nuclear Information System (INIS)

    Oliveira, Karol A.M. de; Crispim, Verginia R.; Ferreira, Francisco J.O.

    2013-01-01

    The neutron radiography technique (NR) with neutrons in the energy range fast to epithermal is a powerful tool used in no-destructive inspection of bulky objects of diverse materials, including those rich in hydrogen, oxygen, nitrogen ad carbon. Thus, it can be used to identify, inclusions, voids and thickness differences in materials such as explosive artifacts and narcotics. Aiming at using NR with fast and epithermal neutrons, an Irradiator was constructed by: a 241 Am-Be source, with 5 Ci activity, a collimator with adjustable collimation rate, L/D; and a shield device composed by plates of borated paraffin and iron. The test specimens chosen were a Beam Purity Indicator (BPI) and an Indicator of Visual Resolution (IVR). The neutron radiography images obtained had a resolution of 444.4 μm and 363.6 μm respectively when registered in: 1) the sheet of the nuclear track solid detector, CR-39 type, through X (n,p) Y nuclear reaction; and 2) Kodak Industrex M radiographic film plate in close contact with a boron converter screen, both stored in a Kodak radiographic cassette. (author)

  15. Bacteriological research for the contamination of digital portable radiography

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Seong Gyu [Dept. of Radiology, Dong A University Hospital, Busan (Korea, Republic of); Lee, Hyo Yeong [Dept. of Radiological Science, Dong Eui University, Busan (Korea, Republic of)

    2017-03-15

    The study was performed to investigate the bacteriological contamination of portable digital radiography system and their detectors in a university hospital. CNS and VRE were detected in the samples collected from vinyl cover on detectors used for the infection control patients. On the other hand, no bacteria was detected in the samples collected from detectors with vinyl cover removed. In the series of imaging of patients from general wards, no bacteria was detected from the patient 1. However, CNS was detected from the patients 2 and 3, CNS and Enterococcus faecalis detected from the patient 4, CNS and Enterococcus casseliflavus detected from the patient 5, and CNS, Enterococcus casseliflavus, and Klebsiella pneumoniae all detected from the patient 6. CNS and Enterococcus faecium were detected in the controller handle of collimator. Also, CNS was detected from the handle of detector and exposure switch. In the treatment gloves of the radiological technologist after the imaging, CNS, Enterococcus gallinarum, and Klebsiella pneumoniae were detected. Therefore, it is recommended for DR portable to take images after sterilizing the detector after taking each image and to use disposable vinyl covers on detectors to remove after imaging. And treatment gloves must be changed after each imaging. Also, hospital infection via portables must be prevented by complete sterilization of the controller handles of collimator which are in frequent contact during imaging and infection education of employees.

  16. Radiation Safety in Industrial Radiography. Specific Safety Guide (French Edition); Surete radiologique en radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-05-15

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in Horizontal-Ellipsis shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  17. Discriminated neutron and X-ray radiography using multi-color scintillation detector

    International Nuclear Information System (INIS)

    Nittoh, Koichi; Takahara, Takeshi; Yoshida, Tadashi; Tamura, Toshiyuki

    1999-01-01

    A new conversion screen Gd 2 O 2 S:Eu is developed, which emits red light on irradiation by thermal neutrons. By applying this in combination with the currently used Gd 2 O 2 S:Tb, a green-light scintillator, in the radiography under a neutron + X-ray coexisting field, we can easily separate the neutron image and the X-ray image by simple color-image processing. This technique enables a non-destructive and detailed inspection of industrial products composed both of light elements (water, plastics, etc.) and heavy elements (metals), widening the horizon of new applications

  18. Discriminated neutron and X-ray radiography using multi-color scintillation detector

    CERN Document Server

    Nittoh, K; Yoshida, T; Tamura, T

    1999-01-01

    A new conversion screen Gd sub 2 O sub 2 S:Eu is developed, which emits red light on irradiation by thermal neutrons. By applying this in combination with the currently used Gd sub 2 O sub 2 S:Tb, a green-light scintillator, in the radiography under a neutron + X-ray coexisting field, we can easily separate the neutron image and the X-ray image by simple color-image processing. This technique enables a non-destructive and detailed inspection of industrial products composed both of light elements (water, plastics, etc.) and heavy elements (metals), widening the horizon of new applications.

  19. Radiography at CERN

    CERN Multimedia

    HSE Unit

    2014-01-01

    What is industrial radiography? It is a non-destructive method with a wide variety of applications, such as inspecting the quality of a weld. It uses high-energy radioactive sources or an X-ray generator.   Is this inspection technique used at CERN? Yes, it is widely used at CERN by the EN-MME Group, which outsources the work to one or more companies, depending on the workload. Is it possible to carry out radiography anywhere at CERN? Yes, it is possible to carry out radiography in any building/accelerator/experiment area at CERN (including in areas which are not normally subject to radiological hazards). When is radiography carried out? It normally takes place outside of working hours (7 p.m. to 6 a.m.). How will I know if radiography is taking place in my building? If this activity is planned in a CERN building, notices will be affixed to all of its main entrance doors at least 24 hours in advance. What are the risks? There is a risk of exposure to very high levels of radiation, dep...

  20. Analysis of painted arts by energy sensitive radiographic techniques with the Pixel Detector Timepix

    Czech Academy of Sciences Publication Activity Database

    Žemlička, J.; Jakůbek, J.; Kroupa, M.; Hradil, David; Hradilová, J.; Mislerová, H.

    2011-01-01

    Roč. 6, - (2011), C01066/1-C01066/7 ISSN 1748-0221 R&D Projects: GA MŠk(CZ) LC06041 Institutional research plan: CEZ:AV0Z40320502 Keywords : inspection with x-rays * pixelated detectors and associated VLSI electronics * X-ray fluorescence (XRF) systems * X-ray radiography and digital radiography (DR) Subject RIV: CA - Inorganic Chemistry Impact factor: 1.869, year: 2011

  1. An overview of digital radiography

    International Nuclear Information System (INIS)

    Aweligiba, S. A.

    2013-04-01

    The medical application of radiography has gained wider study since diagnostic radiology plays a very important role in modern medicine for fast diagnosis and therapy. Digital radiography is a relatively new technology that promises greater accuracy, lesser dose and better manipulation of patient radiology images in hospitals. In this study, a general discussion on digital radiography has been presented. The presentation focuses on the optimisation of doses to patients in the medical application of digital radiography, quality control and quality assurance. A brief presentation on performance indicators in digital radiography has also been presented. The advantages of digital radiography over the conventional film/screen system have been elaborated and its limitations are also outlined. (author)

  2. Proton nuclear scattering radiography

    International Nuclear Information System (INIS)

    Duchazeaubeneix, J.C.; Faivre, J.C.; Garreta, D.

    1982-10-01

    Nuclear scattering of protons allows to radiograph objects with specific properties: direct 3- dimensional radiography, different information as compared to X-ray technique, hydrogen radiography. Furthermore, it is a well adapted method to gating techniques allowing the radiography of fast periodic moving systems. Results obtained on different objects (light and heavy materials) are shown and discussed. The dose delivery is compatible with clinical use, but at the moment, the irradiation time is too long between 1 and 4 hours. Perspectives to make the radiography faster and to get a practical method are discussed

  3. Efficacy of daily bedside chest radiography as visualized by digital luminescence radiography

    International Nuclear Information System (INIS)

    Kirchner, J.; Stueckle, C.A.; Schilling, E.M.; Peters, J.

    2001-01-01

    To determine the diagnostic impact of daily bedside chest radiography in comparison with digital luminescence technique (DLR; storage phosphor radiography) and conventional film screen radiography, a prospective randomized study was completed in 210 mechanically ventilated patients with a total of 420 analysed radiographs. The patients were allocated to two groups: 150 patients underwent DLR, and 60 patients underwent conventional film screen radiography. Radiological analysis was performed consensually and therapeutic efficacy was assessed by the clinicians. There was no statistical significant difference between the frequency of abnormal findings seen on DLR and conventional film screen radiography. In total, 448 abnormal findings were present in 249 of 300 DLR and 97 of 120 conventional film screen radiographs. The most common findings were signs of overhydration (41 %), pleural effusion (31%), partial collapse of the lung (11%) and pneumothorax (2%). One hundred and twenty-three of 448 (27%) of these abnormal findings were thought to have a considerable impact on patient management. The high rate of abnormal findings with significant impact on patient management suggests that the use of daily bedside chest radiography may be reasonable. Copyright (2001) Blackwell Science Pty Ltd

  4. Military radiography

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Historic military uses of radiography are discussed in this chapter: Battle of Adowa in 1986 was the first. Besides describing the early campaigns in which radiography was used, the author discusses the problems faced: a reliable source of electricity; the problems of extreme heat; moving and breakage of equipment. Numerous historical photographs are included. 9 refs

  5. Comparison of the quality of the chest film between digital radiography and conventional high kV radiography

    International Nuclear Information System (INIS)

    Zeng Qingsi; Cen Renli; Chen Ling; He Jianxun; Lin Hanfei

    2003-01-01

    Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with the conventional high KV radiography (78.6%, P < 0.001). Conclusion: Direct digital radiography could provide the chest film with better quality than that with the conventional high kV radiography. The direct digital radiography system is easy to operate, fast in capturing imaging and could provide post-processing techniques, which will facilitate the accurate diagnosis of chest radiography

  6. Proton nuclear scattering radiography

    International Nuclear Information System (INIS)

    Saudinos, J.

    1982-04-01

    Nuclear scattering of protons allows to radiograph objects with specific properties: 3-dimensional radiography, different information as compared to X-ray technique, hydrogen radiography. Furthermore the nuclear scattering radiography (NSR) is a well adapted method to gating techniques allowing the radiography of fast periodic moving objects. Results obtained on phantoms, formalin fixed head and moving object are shown and discussed. The dose delivery is compatible with clinical use, but at the moment, the irradiation time is too long between 1 and 4 hours. Perspectives to make the radiograph faster and to get a practical method are discussed

  7. Characterization of a focusing parabolic guide using neutron radiography method

    International Nuclear Information System (INIS)

    Kardjilov, Nikolay; Boeni, Peter; Hilger, Andre; Strobl, Markus; Treimer, Wolfgang

    2005-01-01

    The aim of the investigation was to test the focusing properties of a new type of focusing neutron guide (trumpet) with parabolically shaped walls. The guide has a length of 431mm with an entrance area of 16x16mm 2 and an output area of 4x4mm 2 . The interior surfaces were coated with a supermirror-surface m=3 and due to their parabolic shape it was expected that an incident parallel beam can be focused in the focal point of the parabolas. To prove this statement the neutron intensity distribution at different distances behind the guide was recorded by means of a standard, high-resolution radiography detector. The experiments were performed at the V12b instrument at HMI with different levels of beam monochromatization demonstrating maximum intensity gains of about 25. The consideration for using the focusing guide for the purposes of cold neutron radiography will be presented

  8. Radiography simulation based on exposure buildup factors for multilayer structures

    International Nuclear Information System (INIS)

    Marinkovic, Predrag; Pesic, Milan

    2009-01-01

    Monte Carlo techniques were usually used to study the effect of scattered photons on a radiographic X-ray image. Such approach is accurate, but computer time consuming. On the other hand, the exposure buildup factors can be used as approximate and efficient assessment to account for the scattering of X-rays. This method uses the known radiography parameters to find the resulting detector exposure due to both scattered and un-collided photons. A model for radiography simulation, based on X-ray dose buildup factor, is proposed. This model includes non-uniform attenuation in voxelized object of imaging (patient body tissue). Composition of patient body is considered as a multi-layer structure. Various empirical formulas exist for multi-layer structure calculations and they all calculate multi-layer buildup factors by combining single-layer buildup factors. The proposed model is convenient in cases when more exact techniques (like Monte Carlo) are not economical. (author)

  9. Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography

    International Nuclear Information System (INIS)

    Dietrich, Tobias J.; Pfirrmann, Christian W.A.; Pankalla, Katja; Buck, Florian M.; Schwab, Alexander

    2013-01-01

    To compare the radiation dose, workflow, patient comfort, and financial break-even of a standard digital radiography and a biplanar low-dose X-ray system. A standard digital radiography system (Ysio, Siemens Healthcare, Erlangen, Germany) was compared with a biplanar X-ray unit (EOS, EOS imaging, Paris, France) consisting of two X-ray tubes and slot-scanning detectors, arranged at an angle of 90 allowing simultaneous vertical biplanar linear scanning in the upright patient position. We compared data of standing full-length lower limb radiographs and whole spine radiographs of both X-ray systems. Dose-area product was significantly lower for radiographs of the biplanar X-ray system than for the standard digital radiography system (e.g. whole spine radiographs; standard digital radiography system: 392.2 ± 231.7 cGy*cm 2 versus biplanar X-ray system: 158.4 ± 103.8 cGy*cm 2 ). The mean examination time was significantly shorter for biplanar radiographs compared with standard digital radiographs (e.g. whole spine radiographs: 449 s vs 248 s). Patients' comfort regarding noise was significantly higher for the standard digital radiography system. The financial break-even point was 2,602 radiographs/year for the standard digital radiography system compared with 4,077 radiographs/year for the biplanar X-ray unit. The biplanar X-ray unit reduces radiation exposure and increases subjective noise exposure to patients. The biplanar X-ray unit demands a higher number of examinations per year for the financial break-even point, despite the lower labour cost per examination due to the shorter examination time. (orig.)

  10. The stationary neutron radiography system

    International Nuclear Information System (INIS)

    Weeks, A.A.; Newell, D.L.; Heidel, C.C.

    1990-01-01

    To provide the high intensity neutron beam and support systems necessary for radiography, the Stationary Neutron Radiography System was constructed at McClellan Air Force Base. The Stationary Neutron Radiography System utilizes a one megawatt TRIGA reactor contained in an Aluminium tank surrounded by eight foot thick concrete walls. There are four neutron beam tubes at inclined angles from the reactor core to separate radiography bays. In three of the bays, robotic systems manipulate aircraft components in the neutron beam, while real-time imaging systems provide images concurrent with the irradiation. Film radiography of smaller components is performed in the remaining bay

  11. X-ray backscatter radiography. Intrusive instead of penetrating, X-ray shadow phenomenon

    International Nuclear Information System (INIS)

    Wrobel, Norma; Kolkoori, Sanjeevareddy; Osterloh, Kurt; European Federation for Non-Destructive Testing

    2013-01-01

    Generally, the primary practical advantage of X-ray backscattering radiography is that there is no need to place a detector on the side of the specimen opposite to the source. Such a situation usually is encountered whenever the specimen is not only standing right in front of a wall or even inside a wall but also if the specimen is such big that radiography is not possible because of the layer thickness to be penetrated. The method used here differs fundamentally from the conventional method to interrogate the object with a scanning beam ('pencil beam') and to collect the whole backscattered radiation from the area. The object is fully illuminated by a (uncollimated) cone beam. Here, the image is recorded with a camera of absorbent material (tungsten, lead), which contains a matrix detector as the image receiver. The optical effect is generated by a special twisted slit collimator which operates according to an extended pinhole camera. The independent positioning of source and camera allows a variable irradiation geometry which causes different images as a result. As a consequence, a complex object in front of a backscattering wall appears completely different than standing alone. So X-ray backscatter images have to be interpreted according to their illumination with X-rays and their surroundings. (orig.)

  12. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... Resources Professions Site Index A-Z X-ray (Radiography) - Chest Chest x-ray uses a very small dose ... Radiography? What is a Chest X-ray (Chest Radiography)? The chest x-ray is the most commonly performed diagnostic ...

  13. An industrial radiography exposure device based on measurement of transmitted gamma-ray intensity

    International Nuclear Information System (INIS)

    Polee, C; Chankow, N; Srisatit, S; Thong-Aram, D

    2015-01-01

    In film radiography, underexposure and overexposure may happen particularly when lacking information of specimen material and hollowness. This paper describes a method and a device for determining exposure in industrial gamma-ray radiography based on quick measurement of transmitted gamma-ray intensity with a small detector. Application software was developed for Android mobile phone to remotely control the device and to display counting data via Bluetooth communication. Prior to film exposure, the device is placed behind a specimen to measure transmitted intensity which is inversely proportional to the exposure. Unlike in using the conventional exposure curve, correction factors for source decay, source-to- film distance, specimen thickness and kind of material are not needed. The developed technique and device make radiographic process economic, convenient and more reliable. (paper)

  14. JRR-3 neutron radiography facility

    International Nuclear Information System (INIS)

    Matsubayashi, M.; Tsuruno, A.

    1992-01-01

    JRR-3 neutron radiography facility consists of thermal neutron radiography facility (TNRF) and cold neutron radiography facility (CNRF). TNRF is installed in JRR-3 reactor building. CNRF is installed in the experimental beam hall adjacent to the reactor building. (author)

  15. Toward practical 3D radiography of pipeline girth welds

    International Nuclear Information System (INIS)

    Wassink, Casper; Hol, Martijn; Flikweert, Arjan; Meer, Philip van

    2015-01-01

    Digital radiography has made its way into in-the-field girth weld testing. With recent generations of detectors and x-ray tubes it is possible to reach the image quality desired in standards as well as the speed of inspection desired to be competitive with film radiography and automated ultrasonic testing. This paper will show the application of these technologies in the RTD Rayscan system. The method for achieving an image quality that complies with or even exceeds prevailing industrial standards will be presented, as well as the application on pipeline girth welds with CRA layers. A next step in development will be to also achieve a measurement of weld flaw height to allow for performing an Engineering Critical Assessment on the weld. This will allow for similar acceptance limits as currently used with Automated Ultrasonic Testing of pipeline girth welds. Although a sufficient sizing accuracy was already demonstrated and qualified in the TomoCAR system, testing in some applications is restricted to time limits. The paper will present some experiments that were performed to achieve flaw height approximation within these time limits

  16. Toward practical 3D radiography of pipeline girth welds

    Energy Technology Data Exchange (ETDEWEB)

    Wassink, Casper, E-mail: casper.wassink@applusrtd.com [Applus RTD Chief Scientist, Rivium 1e straat 80, 2909 LE Capelle a/d IJssel (Netherlands); Hol, Martijn, E-mail: martijn.hol@applusrtd.com; Flikweert, Arjan, E-mail: martijn.hol@applusrtd.com; Meer, Philip van, E-mail: martijn.hol@applusrtd.com [Applus RTD Technological Center, Delftweg 144, 3046 NC Rotterdam (Netherlands)

    2015-03-31

    Digital radiography has made its way into in-the-field girth weld testing. With recent generations of detectors and x-ray tubes it is possible to reach the image quality desired in standards as well as the speed of inspection desired to be competitive with film radiography and automated ultrasonic testing. This paper will show the application of these technologies in the RTD Rayscan system. The method for achieving an image quality that complies with or even exceeds prevailing industrial standards will be presented, as well as the application on pipeline girth welds with CRA layers. A next step in development will be to also achieve a measurement of weld flaw height to allow for performing an Engineering Critical Assessment on the weld. This will allow for similar acceptance limits as currently used with Automated Ultrasonic Testing of pipeline girth welds. Although a sufficient sizing accuracy was already demonstrated and qualified in the TomoCAR system, testing in some applications is restricted to time limits. The paper will present some experiments that were performed to achieve flaw height approximation within these time limits.

  17. Boron determination in tourmaline by neutron induced radiography

    Energy Technology Data Exchange (ETDEWEB)

    Qureshi, A.A. E-mail: aaqureshi@pinstech.org.pk; Akram, M.; Ayub Khan, M.; Khattak, N.U.; Qureshi, I.E.; Khan, H.A

    2001-06-01

    The technique of neutron induced radiography has been applied to determine the boron concentration and its spatial distribution in mineral tourmaline collected from Swat Tourmaline Granite, Northern Pakistan. The technique involves the simultaneous irradiation of sample and a standard fixed on a track detector with thermal neutrons and the counting of alpha and {sup 7}Li tracks produced in the detector from the nuclear reaction {sup 10}B(n,{alpha}){sup 7}Li. Boron concentration is determined by comparing the {sup 7}Li and alpha particle tracks density with that of a standard of known boron concentration. Boron concentration in tourmaline has been found to be (3.40{+-}0.01)% in this study which is on the upper side within the normal range (2.5-3.8)% reported in the world. The presence of somewhat higher concentration of boron in tourmaline indicates that the Swat Tourmaline Granite was generated as a late stage hydrothermal activity during the Himalayan Orogeny.

  18. Radiography in the X-ray region of a laser implosed microball

    International Nuclear Information System (INIS)

    Launspach, J.; Bayer, C.; Billon, D.; Decroisette, M.; Juraszek, D.; Meynial, D.

    1981-05-01

    The OCTAL laser of the Limeil CEA Research Center was used to realize the implosion of small targets containing a mixture of DT and to produce thermonuclear fusion reactions. The experimental device in which the experiments were carried out is called Camelia. Its main component is a vacuum chamber upon which the following elements are fixed: - devices for adjusting the focussing lenses; - a device for positioning targets; - extensive diagnostic means enabling the maximum amount of information to be obtained from each shot. These experiments were performed in order to study laser implosion mechanisms and to measure the density and temperature characteristics that can be reached in this way. The X-ray radiography device is relatively simple. It consists of an X-ray source, the target to be analyzed, one or two stenopies and a detector which is either a simple film (Kodak Kodirex) for diagnostics without temporal resolution or a scanning camera with a slit when temporal resolution is required. The device can be used: - without an x-ray source for emission diagnostics with spatio-temporal resolution, - to study the pre-heating of targets by radiography of the dust at the beginning of the implosion, - for diagnostics of the plasma core by radiography of dust after the implosion [fr

  19. Flat-detector computed tomography (FD-CT)

    International Nuclear Information System (INIS)

    Kalender, Willi A.; Kyriakou, Yiannis

    2007-01-01

    Flat-panel detectors or, synonymously, flat detectors (FDs) have been developed for use in radiography and fluoroscopy with the defined goal to replace standard X-ray film, film-screen combinations and image intensifiers by an advanced sensor system. FD technology in comparison to X-ray film and image intensifiers offers higher dynamic range, dose reduction, fast digital readout and the possibility for dynamic acquisitions of image series, yet keeping to a compact design. It appeared logical to employ FD designs also for computed tomography (CT) imaging. Respective efforts date back a few years only, but FD-CT has meanwhile become widely accepted for interventional and intra-operative imaging using C-arm systems. FD-CT provides a very efficient way of combining two-dimensional (2D) radiographic or fluoroscopic and 3D CT imaging. In addition, FD technology made its way into a number of dedicated CT scanner developments, such as scanners for the maxillo-facial region or for micro-CT applications. This review focuses on technical and performance issues of FD technology and its full range of applications for CT imaging. A comparison with standard clinical CT is of primary interest. It reveals that FD-CT provides higher spatial resolution, but encompasses a number of disadvantages, such as lower dose efficiency, smaller field of view and lower temporal resolution. FD-CT is not aimed at challenging standard clinical CT as regards to the typical diagnostic examinations; but it has already proven unique for a number of dedicated CT applications, offering distinct practical advantages, above all the availability of immediate CT imaging in the interventional suite or the operating room. (orig.)

  20. Semiconductor Thermal Neutron Detector

    Directory of Open Access Journals (Sweden)

    Toru Aoki

    2014-02-01

    Full Text Available The  CdTe  and  GaN  detector  with  a  Gd  converter  have  been developed  and  investigated  as  a  neutron  detector  for neutron  imaging.  The  fabricated  Gd/CdTe  detector  with  the  25  mm  thick  Gd  was  designed  on  the  basis  of  simulation results  of  thermal  neutron  detection  efficiency  and  spatial  resolution.  The  Gd/CdTe  detector  shows  the  detection  of neutron  capture  gamma  ray  emission  in  the  155Gd(n,  g156Gd,  157Gd(n,  g158Gd  and  113Cd(n,  g114Cd  reactions  and characteristic X-ray emissions due to conversion-electrons generated inside the Gd film. The observed efficient thermal neutron detection with the Gd/CdTe detector shows its promise in neutron radiography application. Moreover, a BGaN detector has also investigated to separate neutron signal from gamma-ray clearly. 

  1. Fuji computed radiography (FCR) for the diagnosis of spinal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Yoshichika; Waga, Shiro; Kojima, Tadashi

    1987-04-01

    Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain much precise information about the spinal posterior osteophytes and grafted bone, even when the patients are immobilized in a Halo apparatus. In myelography, the pictures are also clearer; we can see how the root or roots are compressed, how the dura and cord are involved in patients with cervical disc disease, and even the very narrow space between the cord and an intradural tumor. FCR is thus very useful in observing spinal disorders, either in plain films or myelography.

  2. Fuji computed radiography (FCR) for the diagnosis of spinal disorders

    International Nuclear Information System (INIS)

    Kubo, Yoshichika; Waga, Shiro; Kojima, Tadashi

    1987-01-01

    Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain much precise information about the spinal posterior osteophytes and grafted bone, even when the patients are immobilized in a Halo apparatus. In myelography, the pictures are also clearer; we can see how the root or roots are compressed, how the dura and cord are involved in patients with cervical disc disease, and even the very narrow space between the cord and an intradural tumor. FCR is thus very useful in observing spinal disorders, either in plain films or myelography. (author)

  3. Neutron radiography at the HFR Petten

    International Nuclear Information System (INIS)

    Markgraf, J.F.W.

    1990-03-01

    This report contains the five papers on neutron radiography activities at the Petten High Flux Reactor (HFR) presented at the Third World Conference on Neutron Radiography which was held in May 1989 in Osaka, Japan. In addition, a survey on neutron radiography in Europe for industry and research as presented at the SITEF NDT symposium 1989 on European Advances in Non-Destructive Testing, held in Toulouse/France in October 1989 is included. The papers compiled here are concerned with: the neutron radiography services available in Petten; the experience with and applications of neutron radiography at Petten; image evaluation and analysis techniques at Petten; the practical utilization of nitrocellulose film in neutron radiography in Europe; an introduction into the basic principles of neutron radiography; an overview of the neutron radiography facilities in Europe for industry and research; and a survey of typical applications of neutron radiography in industry, research and sciences. It is the intention of this compilation to provide a comprehensive overview of the present Petten activities and European facilities in this young and promising field of non-destructive testing of materials and components from the nuclear and the non-nuclear industries and research organizations, and from the sciences

  4. Student Incivility in Radiography Education.

    Science.gov (United States)

    Clark, Kevin R

    2017-07-01

    To examine student incivility in radiography classrooms by exploring the prevalence of uncivil behaviors along with the classroom management strategies educators use to manage and prevent classroom disruptions. A survey was designed to collect data on the severity and frequency of uncivil student behaviors, classroom management strategies used to address minor and major behavioral issues, and techniques to prevent student incivility. The participants were educators in radiography programs accredited by the Joint Review Committee on Education in Radiologic Technology. Findings indicated that severe uncivil student behaviors in radiography classrooms do not occur as often as behaviors classified as less severe. Radiography educators in this study used a variety of strategies and techniques to manage and prevent student incivility; however, radiography educators who received formal training in classroom management reported fewer incidents of student incivility than those who had not received formal training. The participants in this study took a proactive approach to addressing severe behavioral issues in the classroom. Many radiography educators transition from the clinical environment to the classroom setting with little to no formal training in classroom management. Radiography educators are encouraged to attend formal training sessions to learn how to manage the higher education classroom effectively. Student incivility is present in radiography classrooms. This study provides a foundation for future research on incivility. ©2017 American Society of Radiologic Technologists.

  5. Use of semiconductor detector c-Si microstrip type in obtaining the digital radiographic imaging of phantoms and biological samples of mammary glands

    International Nuclear Information System (INIS)

    Leyva, A.; Cabal, A.; Pinera, I.; Abreu, Y.; Cruz, C. M.; Montano, L. M.; Diaz, C. C.; Fontaine, M.; Ortiz, C. M.; Padilla, F.; De la Mora, R.

    2009-01-01

    The present work synthesizes the experimental results obtained in the characterization of 64 micro strips crystalline silicon detector designed for experiments in high energies physics, with the objective of studying its possible application in advanced medical radiography, specifically in digital mammography and angiography. The research includes the acquisition of two-dimensional radiography of a mammography phantom using the scanning method, and its comparison with similar images simulated mathematically for different X rays sources. The paper also shows the experimental radiography of two biological samples taken from biopsies of mammas, where it is possible to identify the presence of possible pathological lesions. The results reached in this work point positively toward the effective possibility of satisfactorily introducing those advanced detectors in medical digital imaging applications. (Author)

  6. Proton Radiography with CR-39 by Using the Protons from High Power Femto-second Laser System

    International Nuclear Information System (INIS)

    Choi, Chang Il; Lee, Dong Hoon; Kang, Byoung Hwi; Kim, Yong Kyun; Choi, Il Woo; Ko, Do Kyeong; Lee, Jong Min

    2008-01-01

    Proton radiography techniques are useful to obtain a high quality image of a thin object, because protons travel straight in matter. Generation of the high energy proton using conventional accelerator costs high and requires large accelerating facility. But proton radiography using high power femto-second(10-15 second) laser has been interested, because it can generate high energy protons at lower price than the conventional accelerator like a cyclotron. For this study, we used the CR-39 SSNTD (Solid State Nuclear Track Detector) as the proton radiography screen. Commonly, CR-39 is used to detect the tracks of energetic charged particles. Incident energetic charged particles left latent tracks in the CR-39, in the form of broken molecular chains and free radicals. These latent tracks show high chemical reactivity. After chemical etching with the caustic alkali solution such as NaOH or KOH, tracks are appeared to forms of hole. If protons with various energies enter the two targets with another thickness, number of protons passed through the target per unit area is different each other. Using this feature of protons, we can a proton radiographic image with CR-39. We studied proton radiography with CR-39 by using energetic protons from high power femto-second laser and evaluated potentiality of femto-second laser as new energetic proton generator for radiography

  7. Radiological safety aspects of industrial radiography

    International Nuclear Information System (INIS)

    Hanekom, A.P.

    1983-01-01

    Industrial radiography and especially gamma-radiography, has established itself as a very powerful tool in non-destructive testing. Unfortunately there is an amount of risk attached to the use of industrial radiography. The primary causes of radiography accidents include: working conditions, equipment failure and lack of supervisory control. To alleviate the radiological risks involved with gamma-radiography, the Atomic Energy Corporation (AEC) has imposed various conditions for the possession, use, and conveyance of radioactive material. This includes personnel training and equipment specifications

  8. WE-EF-303-04: An Advanced Image Processing Method to Improve the Spatial Resolution of Proton Radiographies

    International Nuclear Information System (INIS)

    Rinaldi, I; Parodi, K; Krah, N

    2015-01-01

    Purpose: We present an optimization method to improve the spatial resolution and the water equivalent thickness accuracy of proton radiographies. Methods: The method is designed for imaging systems measuring only the residual range of protons without relying on tracker detectors to determine the beam trajectory before and after the target. Specifically, the method was used for an imaging set-up consisting of a stack of 61 parallel-plate ionization chambers (PPIC) working as a range telescope. The method uses a decomposition approach of the residual range signal measured by the PPIC and constructs subimages with small size pixels geometrically rearranged and appropriately averaged to be merged into a final single radiography. The method was tested using Monte Carlo simulated and experimental proton radiographies of a PMMA step phantom and an anthropomorphic head phantom. Results: For the step phantom, the effective spatial resolution was found to be 4 and 3 times higher than the nominal resolution for the simulated and experimental radiographies, respectively. For the head phantom, a gamma index was calculated to quantify the conformity of the simulated proton radiographies with a digitally reconstructed X-ray radiography convolved with a Gaussian kernel equal to the proton beam spot-size. For DTA=2.5 mm and RD=2.5%, the passing ratio was 100%/85% for the optimized/non-optimized case, respectively. An extension of the method allows reducing the dose given to the patient during radiography acquisition. We show that despite a dose reduction of 25 times (leading to a dose of 0.016 mGy for the current imaging set-up), the image quality of the optimized radiographies remains fairly unaffected for both the simulated and experimental results. Conclusion: The optimization method leads to a significant increase of the spatial resolution allowing recovering image details that are unresolved in non-optimized radiographies. These results represent a major step towards clinical

  9. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...

  10. Advanced X-ray radiography and tomography in several engineering applications

    Czech Academy of Sciences Publication Activity Database

    Vavřík, Daniel; Dammer, J.; Jakůbek, J.; Jeon, I.; Jiroušek, Ondřej; Kroupa, M.; Zlámal, Petr

    2011-01-01

    Roč. 633, č. 1 (2011), s. 152-155 ISSN 0168-9002. [International workshop on radiation imaging detectors /11./. Praha, 26.06.2009-02.07.2009] R&D Projects: GA ČR(CZ) GA103/09/2101 Grant - others:GA MŠk(CZ) LC06041 Program:LC Institutional research plan: CEZ:AV0Z20710524 Keywords : digital radiography * computed tomography * X-ray crack imaging Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 1.207, year: 2011 http://dx.doi.org/10.1016/j.nima.2010.06.152

  11. Neutron radiography

    International Nuclear Information System (INIS)

    Bayon, G.

    1989-01-01

    Neutronography or neutron radiography, a non-destructive test method which is similar in its principle to conventional X-ray photography, presently occupies a marginal position among non-destructive test methods (NDT) (no source of suitable performance or cost). Neutron radiography associated with the ORPHEE reactor permits industrial testing; it can very quickly meet a cost requirement comparable to that of conventional test methods. In 1988, 2500 parts were tested on this unit [fr

  12. Industrial radiography

    International Nuclear Information System (INIS)

    1994-01-01

    This Health and Safety Executive Information Sheet on industrial radiography aims to inform directors and managers of industrial radiography companies on the safety precautions necessary to ensure that their personnel do not exceed dose guidelines for exposure to ionizing radiation. The Ionising Radiations Regulations 1985 (IRR85) require that exposure doses for radiographers are kept as low reasonably practicable. Equipment maintenance, and the employment of proper emergency procedures will help to ensure personnel safety. (UK)

  13. Computed radiography simulation using the Monte Carlo code MCNPX

    International Nuclear Information System (INIS)

    Correa, S.C.A.; Souza, E.M.; Silva, A.X.; Lopes, R.T.

    2009-01-01

    Simulating x-ray images has been of great interest in recent years as it makes possible an analysis of how x-ray images are affected owing to relevant operating parameters. In this paper, a procedure for simulating computed radiographic images using the Monte Carlo code MCNPX is proposed. The sensitivity curve of the BaFBr image plate detector as well as the characteristic noise of a 16-bit computed radiography system were considered during the methodology's development. The results obtained confirm that the proposed procedure for simulating computed radiographic images is satisfactory, as it allows obtaining results comparable with experimental data. (author)

  14. Computed radiography simulation using the Monte Carlo code MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Correa, S.C.A. [Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil); Centro Universitario Estadual da Zona Oeste (CCMAT)/UEZO, Av. Manuel Caldeira de Alvarenga, 1203, Campo Grande, 23070-200, Rio de Janeiro, RJ (Brazil); Souza, E.M. [Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil); Silva, A.X., E-mail: ademir@con.ufrj.b [PEN/COPPE-DNC/Poli CT, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil); Cassiano, D.H. [Instituto de Radioprotecao e Dosimetria/CNEN Av. Salvador Allende, s/n, Recreio, 22780-160, Rio de Janeiro, RJ (Brazil); Lopes, R.T. [Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil)

    2010-09-15

    Simulating X-ray images has been of great interest in recent years as it makes possible an analysis of how X-ray images are affected owing to relevant operating parameters. In this paper, a procedure for simulating computed radiographic images using the Monte Carlo code MCNPX is proposed. The sensitivity curve of the BaFBr image plate detector as well as the characteristic noise of a 16-bit computed radiography system were considered during the methodology's development. The results obtained confirm that the proposed procedure for simulating computed radiographic images is satisfactory, as it allows obtaining results comparable with experimental data.

  15. SU-E-I-51: Quantitative Assessment of X-Ray Imaging Detector Performance in a Clinical Setting - a Simple Approach Using a Commercial Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Sjoeberg, J; Bujila, R; Omar, A; Nowik, P; Mobini-Kesheh, S; Lindstroem, J [Karolinska University Hospital, Solna (Sweden)

    2015-06-15

    Purpose: To measure and compare the performance of X-ray imaging detectors in a clinical setting using a dedicated instrument for the quantitative determination of detector performance. Methods: The DQEPro (DQE Instruments Inc., London, Ontario Canada) was used to determine the MTF, NPS and DQE using an IEC compliant methodology for three different imaging modalities: conventional radiography (CsI-based detector), general-purpose radioscopy (CsI-based detector), and mammography (a-Se based detector). The radiation qualities (IEC) RQA-5 and RQA-M-2 were used for the CsI-based and a-Se-based detectors, respectively. The DQEPro alleviates some of the difficulties associated with DQE measurements by automatically positioning test devices over the detector, guiding the user through the image acquisition process and providing software for calculations. Results: A comparison of the NPS showed that the image noise of the a-Se detector was less correlated than the CsI detectors. A consistently higher performance was observed for the a-Se detector at all spatial frequencies (MTF: 0.97@0.25 cy/mm, DQE: 0.72@0.25 cy/mm) and the DQE drops off slower than for the CsI detectors. The CsI detector used for conventional radiography displayed a higher performance at low spatial frequencies compared to the CsI detector used for radioscopy (DQE: 0.65 vs 0.60@0.25 cy/mm). However, at spatial frequencies above 1.3 cy/mm, the radioscopy detector displayed better performance than the conventional radiography detector (DQE: 0.35 vs 0.24@2.00 cy/mm). Conclusion: The difference in the MTF, NPS and DQE that was observed for the two different CsI detectors and the a-Se detector reflect the imaging tasks that the different detector types are intended for. The DQEPro has made the determination and calculation of quantitative metrics of X-ray imaging detector performance substantially more convenient and accessible to undertake in a clinical setting.

  16. Cone-Beam CT with Flat-Panel-Detector Digital Angiography System: Early Experience in Abdominal Interventional Procedures

    International Nuclear Information System (INIS)

    Hirota, Shozo; Nakao, Norio; Yamamoto, Satoshi; Kobayashi, Kaoru; Maeda, Hiroaki; Ishikura, Reiichi; Miura, Koui; Sakamoto, Kiyoshi; Ueda, Ken; Baba, Rika

    2006-01-01

    We developed a cone-beam computed tomography (CBCT) system equipped with a large flat-panel detector. Data obtained by 200 o rotation imaging are reconstructed by means of CBCT to generate three-dimensional images. We report the use of CBCT angiography using CBCT in 10 patients with 8 liver malignancies and 2 hypersplenisms during abdominal interventional procedures. CBCT was very useful for interventional radiologists to confirm a perfusion area of the artery catheter wedged on CT by injection of contrast media through the catheter tip, although the image quality was slightly degraded, scoring as 2.60 on average by streak artifacts. CBCT is space-saving because it does not require a CT system with a gantry, and it is also time-saving because it does not require the transfer of patients

  17. Quantitative image quality evaluation of pixel-binning in a flat-panel detector for x-ray fluoroscopy

    International Nuclear Information System (INIS)

    Srinivas, Yogesh; Wilson, David L.

    2004-01-01

    X-ray fluoroscopy places stringent design requirements on new flat-panel (FP) detectors, requiring both low-noise electronics and high data transfer rates. Pixel-binning, wherein data from more that one detector pixel are collected simultaneously, not only lowers the data transfer rate but also increases x-ray counts and pixel signal-to-noise ratio (SNR). In this study, we quantitatively assessed image quality of image sequences from four acquisition methods; no-binning and three types of binning; in synthetic images using a clinically relevant task of detecting an extended guidewire in a four-alternative forced-choice paradigm. Binning methods were conventional data-line (D) and gate-line (G) binning, and a novel method in which alternate frames in an image sequence used D and G binning. Two detector orientations placed the data lines either parallel or perpendicular to the guide wire. At a low exposure of 0.6 μR (1.548x10 -10 C/kg) per frame, irrespective of detector orientation, D binning with its reduced electronic noise was significantly (p -10 C/kg) per frame, with data lines parallel to the guidewire, detection with D binning was significantly (p<0.1) better than G binning. However, with data lines perpendicular to the guidewire, G binning was significantly (p<0.1) better than D binning because the partial area effect was reduced. Alternate binning was the best binning method when results were averaged over both orientations, and it was as good as the best binning method at either orientation. In addition, at low and high exposures, alternate binning gave a temporally fused image with a smooth guidewire, an important image quality feature not assessed in a detection experiment. While at high exposure, detection with no binning was as good, or better, than the best binning method, it might be impractical at fluoroscopy imaging rates. A computational observer model based on signal detection theory successfully fit data and was used to predict effects of

  18. Digital chest radiography: an update on modern technology, dose containment and control of image quality

    International Nuclear Information System (INIS)

    Schaefer-Prokop, Cornelia; Venema, Henk W.; Neitzel, Ulrich; Uffmann, Martin; Prokop, Mathias

    2008-01-01

    The introduction of digital radiography not only has revolutionized communication between radiologists and clinicians, but also has improved image quality and allowed for further reduction of patient exposure. However, digital radiography also poses risks, such as unnoticed increases in patient dose and suboptimum image processing that may lead to suppression of diagnostic information. Advanced processing techniques, such as temporal subtraction, dual-energy subtraction and computer-aided detection (CAD) will play an increasing role in the future and are all targeted to decrease the influence of distracting anatomic background structures and to ease the detection of focal and subtle lesions. This review summarizes the most recent technical developments with regard to new detector techniques, options for dose reduction and optimized image processing. It explains the meaning of the exposure indicator or the dose reference level as tools for the radiologist to control the dose. It also provides an overview over the multitude of studies conducted in recent years to evaluate the options of these new developments to realize the principle of ALARA. The focus of the review is hereby on adult applications, the relationship between dose and image quality and the differences between the various detector systems. (orig.)

  19. Detector applications in medecine and biology

    CERN Document Server

    Del Guerra, Alberto

    1995-01-01

    In recent years new diagnostic and therapeutic methods have been attracting more and more dedicated attention by the scientific community.The goal is a better understanding of the anatomy, physiology and pathology of the human being in an effort to find more appropriate medical prevention, diagnosis and therapy.Many of the achievements obtained so far derive from the use and the optimisation of detectors and techniques,which originated in the other fields of physics. The spin-off of High Energy Physics to Medical Physics has been particularly relevant in the field of detectors for medical imaging and especially for medical imaging with ionizing radiation. In this series of lectures,starting from the requests of each technique and or application I will attempt to present a survey of the detectors for medecine and biology. Various fields of medical imaging will be touched : radiology,digital radiography,mammography and radiotherapy. The capabilities of the major types of detectors (1-D and 2-D position sensitiv...

  20. Radiography using californium-252 neutron sources

    International Nuclear Information System (INIS)

    Ray, J.W.

    1975-01-01

    The current status in the technology of neutron radiography using californium-252 neutron sources is summarized. Major emphasis is on thermal neutron radiography since it has the widest potential applicability at the present time. Attention is given to four major factors which affect the quality and useability of thermal neutron radiography: source neutron thermalization, neutron beam extraction geometry, neutron collimator dimensions, and neutron imaging methods. Each of these factors has a major effect on the quality of the radiographs which are obtained from a californium source neutron radiography system and the exposure times required to obtain the radiographs; radiograph quality and exposure time in turn affect the practicality of neutron radiography for specific nondestructive inspection applications. A brief discussion of fast neutron radiography using californium-252 neutron sources is also included. (U.S.)

  1. Water calibration measurements for neutron radiography: Application to water content quantification in porous media

    Energy Technology Data Exchange (ETDEWEB)

    Kang, M., E-mail: kangm@ornl.gov [Department of Earth and Planetary Sciences, University of Tennessee, Knoxville, TN (United States); Chemical and Engineering Materials Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Bilheux, H.Z., E-mail: bilheuxhn@ornl.gov [Chemical and Engineering Materials Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Voisin, S. [Computational Sciences and Engineering Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Cheng, C.L.; Perfect, E. [Department of Earth and Planetary Sciences, University of Tennessee, Knoxville, TN (United States); Horita, J. [Department of Geosciences, Texas Tech University, Lubbock, TX (United States); Warren, J.M. [Environmental Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    2013-04-21

    Using neutron radiography, the measurement of water thickness was performed using aluminum (Al) water calibration cells at the High Flux Isotope Reactor (HFIR) Cold-Guide (CG) 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA. Calibration of water thickness is an important step to accurately measure water contents in samples of interest. Neutron attenuation by water does not vary linearly with thickness mainly due to beam hardening and scattering effects. Transmission measurements for known water thicknesses in water calibration cells allow proper correction of the underestimation of water content due to these effects. As anticipated, strong scattering effects were observed for water thicknesses greater than 0.2 cm when the water calibration cells were positioned close to the face of the detector/scintillator (0 and 2.4 cm away, respectively). The water calibration cells were also positioned 24 cm away from the detector face. These measurements resulted in less scattering and this position (designated as the sample position) was used for the subsequent experimental determination of the neutron attenuation coefficient for water. Neutron radiographic images of moist Flint sand in rectangular and cylindrical containers acquired at the sample position were used to demonstrate the applicability of the water calibration. Cumulative changes in the water volumes within the sand columns during monotonic drainage determined by neutron radiography were compared with those recorded by direct reading from a burette connected to a hanging water column. In general, the neutron radiography data showed very good agreement with those obtained volumetrically using the hanging water-column method. These results allow extension of the calibration equation to the quantification of unknown water contents within other samples of porous media.

  2. Dental radiography

    International Nuclear Information System (INIS)

    Shekhdar, J.

    1993-01-01

    Dental radiography must comply with the same regulations with which conventional radiography complies. Radiation doses to individual patients are low but, because of the large number of patients X-rayed, the collective dose to the population is not negligible. Care in siting and regular maintenance of the equipment will reduce doses to both staff and patients. To produce X-ray films with a good image quality using a low radiation dose requires attention to film processing; this is often a neglected area. (Author)

  3. Double beam neutron radiography facility

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-09-01

    The DR1 reactor at Risoe is used as a neutron source for neutron radiography. In the double-beam neutron radiography facility a neutron flux of an intensity of 1.4 and 1.8 x 10 6 n. cm -2 . s -1 reaches the object to be radiographed. The transport and exposure container used for neutron radiography of irradiated nuclear fuel rods is described, and the exposure technique and procedure are reviewed. The mode by which single neutron radiographs are assembled and assessed is described. This report will be published in the ''Neutron Radiography Newsletter''. (author)

  4. Magnification radiography

    International Nuclear Information System (INIS)

    Genant, H.K.; Resnick, D.

    1988-01-01

    The relative clinical value of magnification compared with conventional radiography for skeletal applications is presented qualitatively. The presentation is based on the authors' experience with over 25,000 cases in which magnification has been used. For most areas in which magnification (optical or geometric) proves useful, subtle abnormalities of clinical importance are present at bone surfaces or at host-lesion interfaces. This is particularly true for arthritis and metabolic and infectious disorders of bone. In additional instances, serial assessment of the progression of disease or its response to therapy is enhanced by magnification. When gross abnormalities are present, as in most instances of trauma and bone dysplasia, the findings are obvious on conventional radiography, and magnification is not necessary. Thus, the magnification techniques appear to provide important diagnostic information, depending upon the anatomic part that is studied and the clinical question that is posed. It is also apparent that the demonstration of subtle skeletal abnormalities to clinical colleagues for educational purposes is greatly enhanced by magnification radiography

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  6. Applications of pixellated GaAs X-ray detectors in a synchrotron radiation beam

    CERN Document Server

    Watt, J; Campbell, M; Mathieson, K; Mikulec, B; O'Shea, V; Passmore, M S; Schwarz, C; Smith, K M; Whitehill, C

    2001-01-01

    Hybrid semiconductor pixel detectors are being investigated as imaging devices for radiography and synchrotron radiation beam applications. Based on previous work in the CERN RD19 and the UK IMPACT collaborations, a photon counting GaAs pixel detector (PCD) has been used in an X-ray powder diffraction experiment. The device consists of a 200 mu m thick SI-LEC GaAs detector patterned in a 64*64 array of 170 mu m pitch square pixels, bump-bonded to readout electronics operating in single photon counting mode. Intensity peaks in the powder diffraction pattern of KNbO/sub 3/ have been resolved and compared with results using the standard scintillator, and a PCD predecessor (the Omega 3). The PCD shows improved speed, dynamic range, 2-D information and comparable spatial resolution to the standard scintillator based systems. It also overcomes the severe dead time limitations of the Omega 3 by using a shutter based acquisition mode. A brief demonstration of the possibilities of the system for dental radiography and...

  7. Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment.

    Science.gov (United States)

    Pjontek, Rastislav; Önenköprülü, Belgin; Scholz, Bernhard; Kyriakou, Yiannis; Schubert, Gerrit A; Nikoubashman, Omid; Othman, Ahmed; Wiesmann, Martin; Brockmann, Marc A

    2016-08-01

    Flat panel detector CT angiography with intravenous contrast agent injection (IV CTA) allows high-resolution imaging of cerebrovascular structures. Artifacts caused by metallic implants like platinum coils or clips lead to degradation of image quality and are a significant problem. To evaluate the influence of a prototype metal artifact reduction (MAR) algorithm on image quality in patients with intracranial metallic implants. Flat panel detector CT after intravenous application of 80 mL contrast agent was performed with an angiography system (Artis zee; Siemens, Forchheim, Germany) using a 20 s rotation protocol (200° rotation angle, 20 s acquisition time, 496 projections). The data before and after MAR of 26 patients with a total of 34 implants (coils, clips, stents) were independently evaluated by two blinded neuroradiologists. MAR improved the assessability of the brain parenchyma and small vessels (diameter metallic implants and at a distance of 6 cm (p<0.001 each, Wilcoxon test). Furthermore, MAR significantly improved the assessability of parent vessel patency and potential aneurysm remnants (p<0.005 each, McNemar test). MAR, however, did not improve assessability of stented vessels. When an intravenous contrast protocol is used, MAR significantly ameliorates the assessability of brain parenchyma, vessels, and treated aneurysms in patients with intracranial coils or clips. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. Transitioning to digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, F., E-mail: Francisco.Miranda@pwc.ca [Pratt & Whitney Canada, Longueuil, Quebec (Canada)

    2015-09-15

    This article provides insight on the technical and business considerations necessary to implement or to transition to digital radiography Continued refinements in digital radiography technology have resulted in significant improvements in image quality and detectability of indications. These improvements have resulted in the acceptance of the technology by users and aerospace primes for final product inspection and disposition. Digital radiography has also been identified as an interesting cost reduction initiative with the potential of providing gains in productivity through increased throughput and decreased inspection lead-times and resulting costs. (author)

  9. Digital radiography of the chest

    International Nuclear Information System (INIS)

    Sakurai, Kenji; Hachiya, Junichi; Korenaga, Tateo; Nitatori, Toshiaki; Miyasaka, Yasuo; Furuya, Yoshiro

    1984-01-01

    Initial clinical experience in digital chest radiography utilizing photostimulable phosphor and scanning laser stimulated luminescence was reported. Image quality of conventional film/screen radiography and digital radiography was compared in 30 normal cases. Reflecting wide dynamic range of the system, improved image quality was confirmed in all 30 cases, particularly in visibility of various mediastinal structures and pulmonary vessels. High sensor sensitivity of the system enabled digital radiography to reduce radiation dose requirement significantly. Diagnostically acceptable chest images were obtained with approximately 1/5 of routine dose for conventional radiography without significant image quality degradation. Some artifact created by digital processing were mostly overcome by a routine use of simultaneous display of two different types of image processing and therefore was not an actual drawback from diagnostic standpoint. Further technical advancement of the system to be seen for digital storage, retrieval and tranceference of images. (author)

  10. neutron radiography. Report prepared from contributions by members of the MOD Working Party on Neutron Radiography

    International Nuclear Information System (INIS)

    Halmshaw, R.

    1977-03-01

    Radiography with thermal or cold neutrons has some special advantages over X-rays and gamma rays, and some facilities for neutron radiography exist in the Ministry of Defence. This report gives a brief and simple description of the technique, its advantages and disadvantages, and is illustrated with a number of Ordnance applications taken from MOD work, to show examples where neutron radiographs provided extra important information not available from X- or gamma radiography. The facilities available in the UK for neutron radiography are listed. (author)

  11. Quality assurance in digital radiography

    International Nuclear Information System (INIS)

    Busch, H.P.; Lehmann, K.J.

    1989-01-01

    At present, there is no standard way of evaluating performance characteristics of digital radiography systems. Continuous measurements of performance parameters are necessary in order to obtain images of high quality. Parameters of quality assurance in digital radiography, which can be evaluated with simple, quick methods, are spatial resolution, low-contrast detectability, dynamic range and exposure dose. Spatial resolution was determined by a lead bar pattern, whereas the other parameters were measured by commercially available phantoms. Performance measurements of 10 digital subtraction angiography (DSA) units and one digital radiography system for unsubtracted digital radiography were assessed. From these results, recommendations for performance parameter levels will be discussed. (author)

  12. Selenium-based digital radiography of the cervical spine. Comparison with screen-film radiography for the depiction of anatomic details

    International Nuclear Information System (INIS)

    Ludwig, K.; Diederich, S.; Wormanns, D.; Link, T.M.; Lenzen, H.; Heindel, W.

    2002-01-01

    Purpose: To compare selenium-based digital radiography with conventional screen-film radiography of the cervical spine. Materials and Methods: In a prospective study X-ray images of the cervical spine were obtained in 25 patients using selenium-based digital radiography and conventional screen-film radiography. All images were clinically indicated. Selenium-based digital radiography and conventional screen-film radiography were used in a randomized order. Four radiologists independently evaluated all 50 examinations for the visibility of 76 anatomic details according to a five-level confidence scale (1=not visible, 5=very good visibility). From the evaluation of these anatomic details scores for the upper and middle cervical spine, the cervicothoracic junction and the cervical soft tissues were calculated. The scores for selenium-based digital radiography and conventional screen-film radiography were compared using Wilcoxon's signed rank test. Results: From a total of 15,200 observations (608 per patient) the following scores were calculated for selenium-based digital radiography and for screen-film radiography, respectively: Upper cervical spine 3.88 and 3.94; middle cervical spine 4.60 and 4.48; cervico-thoracic junction 3.64 and 2.62; cervical soft tissue 4.47 and 3.46. The differences between the last two scores were statistically significant (p [de

  13. Standard guide for digital detector array radiology

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This standard is a user guide, which is intended to serve as a tutorial for selection and use of various digital detector array systems nominally composed of the detector array and an imaging system to perform digital radiography. This guide also serves as an in-detail reference for the following standards: Practices E2597, , and E2737. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Radioisotopes - their applications in industrial radiography

    International Nuclear Information System (INIS)

    Rao, H.R.S.

    1977-01-01

    The nature of radioisotopes and their industrial applications with special reference to industrial radiography are outlined. The various aspects of industrial radiography such as source size, source containers, films, density of radiography, radiographic quality and applications are discussed in brief. (M.G.B.)

  15. Towards a muon radiography of the Puy de Dôme

    Directory of Open Access Journals (Sweden)

    C. Cârloganu

    2013-02-01

    Full Text Available High-energy (above a few hundred GeV atmospheric muons are a natural probe for geophysical studies. They can travel through kilometres of rock allowing for a radiography of the density distribution within large structures, like mountains or volcanoes. A collaboration between volcanologists, astroparticle and particle physicists, Tomuvol was formed in 2009 to study tomographic muon imaging of volcanoes with high-resolution, large-scale tracking detectors. We report on two campaigns of measurements at the flank of the Puy de Dôme using glass resistive plate chambers (GRPCs developed for particle physics, within the CALICE collaboration.

  16. Development of hybrid low-pressure MSGC neutron detectors

    International Nuclear Information System (INIS)

    Gebauer, B.; Alimov, S.S.; Klimov, A.Yu.; Levchanovski, F.V.; Litvinenko, E.I.; Nikiforov, A.S.; Prikhodko, V.I.; Richter, G.; Rogov, V.; Schulz, Ch.; Shashkin, V.I.; Wilhelm, M.; Wilpert, Th.

    2004-01-01

    For very high rate and resolution time-resolved experiments at next generation pulsed spallation neutron sources like ESS large-area hybrid low-pressure micro-strip gas chamber detectors are being developed. Due to their thin composite converter foil and exponential gas multiplication commencing at the converter surfaces the detectors are free of parallax, and according to detailed modeling the very high transverse and longitudinal localization accuracies in the conversion and gas multiplication processes allow position and time resolutions of ∼100 μm and 8 cps. This will open up novel applications based on time-of-flight (TOF) and single-event detection with very high dynamic range, replacing integrating CCD and image plate detectors, e.g. in radiography/tomography, TOF Laue diffraction, single crystal diffraction and focusing low-Q SANS. In this conference report new results concerning the technical realization of this detector system are reported in conjunction with a brief summary of the detector principle and with reference to earlier results

  17. Euratom Neutron Radiography Working Group

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    reactor fuel as well as establish standards for radiographic image quality of neutron radiographs. The NRWG meets once a year in each of the neutron radiography centers to review the progress made and draw plans for the future. Besides, ad-hoc sub-groups or. different topics within the field of neutron......In 1979 a Neutron Radiography Working Group (NRWG) was constituted within Buratom with the participation of all centers within the European Community at which neutron facilities were available. The main purpose of NRWG was to standardize methods and procedures used in neutron radiography of nuclear...... radiography are constituted. This paper reviews the activities and achievements of the NRWG and its sub-groups....

  18. Aerogel for FARICH detector

    Energy Technology Data Exchange (ETDEWEB)

    Barnyakov, A.Yu. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Barnyakov, M.Yu. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State Technical University, Karl Marks 20, Novosibirsk 630073 (Russian Federation); Bobrovnikov, V.S.; Buzykaev, A.R.; Gulevich, V.V. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Danilyuk, A.F. [Boreskov Institute of Catalysis, Lavrentieva 5, Novosibirsk 630090 (Russian Federation); Kononov, S.A.; Kravchenko, E.A. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State University, Pirogova 2, Novosibirsk 630090 (Russian Federation); Kuyanov, I.A. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Lopatin, S.A. [Boreskov Institute of Catalysis, Lavrentieva 5, Novosibirsk 630090 (Russian Federation); Onuchin, A.P.; Ovtin, I.V.; Podgornov, N.A. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State Technical University, Karl Marks 20, Novosibirsk 630073 (Russian Federation); Porosev, V.V. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Predein, A.Yu.; Protsenko, R.S. [Boreskov Institute of Catalysis, Lavrentieva 5, Novosibirsk 630090 (Russian Federation)

    2014-12-01

    We present our current experience in preparation of focusing aerogels for the Focusing Aerogel RICH detector. Multilayer focusing aerogel tiles have been produced in Novosibirsk by a collaboration of the Budker Institute of Nuclear Physics and Boreskov Institute of Catalysis since 2004. We have obtained 2–3–4-layer blocks with the thickness of 30–45 mm. In 2012, the first samples of focusing blocks with continuous density (refractive index) gradient along thickness were produced. This technology can significantly reduce the contribution from the geometric factor of the radiator thickness to the resolution of the measured Cherenkov angle in the FARICH detector. The special installation was used for automatic control of reagents ratio during the synthesis process. The first samples were tested using the digital radiography method and on the electron beam with the FARICH prototype.

  19. Fracture healing: direct magnification versus conventional radiography

    International Nuclear Information System (INIS)

    Link, T.M.; Kessler, T.; Lange, T.; Overbeck, J.; Fiebich, M.; Peters, P.E.

    1994-01-01

    The aim of the study was to evaluate the potential of magnification radiography in diagnosing fracture healing and assessing its complications. Seventy-three patients with fractures or who had undergone osteotomy were radiographed with both conventional (non-magnified) and magnification (5-fold) techniques. Since 10 patients were radiographed twice and 1 three times, 83 radiographs using each technique were obtained. All radiographs were analysed and the findings correlated with the patients' follow-up studies. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 μm. As an imaging system, digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Magnification radiography proved superior to conventional radiography in 47% of cases: endosteal and periosteal callus formations were seen earlier and better in 26 cases, and osseous union could be evaluated with greater certainty in 33 cases. In 49% of cases magnification radiography was equal and in 4% inferior to conventional radiography. Additionally an ''inter-observer analysis'' was carried out. Anatomical and pathological structures were classified into one of four grades. Results were significantly (P < 0.01) better using magnification radiography. We conclude that the magnification technique is a good method for monitoring fracture healing in its early stages. (orig.)

  20. Development of the MCNPX model for the portable HPGe detector

    International Nuclear Information System (INIS)

    Koleska, Michal; Viererbl, Ladislav; Marek, Milan

    2014-01-01

    The portable HPGe coaxial detector Canberra Big MAC is used in LVR-15 research reactor for spectrometric measurement of spent nuclear fuel. The fuel is measured in the dedicated system located in the spent fuel pool situated near the reactor. For the purpose of the spectrometric system calibration, the detector was precisely modeled with the MCNPX code. This model was constructed with the data acquired from the technical specification provided by the manufacturer and from the data obtained by the radiography of the crystal. The detector model was verified on the experimental data measured with available standard radionuclide sources and on-site prepared 110m Ag source. - Highlights: • Inner structure of the HPGe detector is determined. • An MCNPX model of the detector is developed. • The model is verified using different sources for two measurement geometries

  1. Finite Element Analysis of the SciFi-Nomex-Sandwich Panels

    CERN Document Server

    Schultz von Dratzig, Arndt

    2015-01-01

    A finite element analysis of the SciFi-Nomex-sandwich panels has been carried out in order to investigate their thermo-mechanical properties. This does not include the cooling of the silicon photomultipliers but is restricted to the panels themselves. Two kinds of panels have been considered: panels with 40 mm thickness and panels with 50 mm thickness. Both versions are equipped with mats of six layers of scintillating fibers. The analyses were carried out for a series of mechanical and thermal loads which might occur during the production or installation of the detector. For both versions the stiffnesses prove to be sufficient and no critical stresses or strains are found.

  2. First experience with digital radiography

    International Nuclear Information System (INIS)

    Buchmann, F.

    1987-01-01

    The digital radiogram is explained, its advantages being the various possibilities of image processing, loss-free transmission, recording and storage capabilities, and in special cases, prompt availability of processed images. Digital subtraction angiography (DSA) and the high-resolution method of digital, luminescent radiography, which replaced the conventional film-foil radiography, are explained as the first developments for the introduction of digital radiography, which today already is an applicable technique. (orig./MG) [de

  3. Problems associated with digital luminescence radiography in the neonate and young infant. Problems with digital radiography.

    Science.gov (United States)

    Arthur, R J; Pease, J N

    1992-01-01

    An evaluation of the Siemens Digiscan has been undertaken to determine whether digital luminescence radiography (DLR) could replace conventional radiography in the examination of the neonate and young infant. Whilst the overall image quality of the digital radiograph was consistently higher than for conventional radiography the difference was less marked than we had expected. Furthermore, the potential for reduction in radiation dose by reducing the repeat rate due to incorrect exposure was limited. The potential advantages of DLR have been critically examined in relationship to neonatal radiography and a number of problems encountered during the evaluation have been highlighted.

  4. A novel method for contrast-to-noise ratio (CNR) evaluation of digital mammography detectors

    International Nuclear Information System (INIS)

    Baldelli, P.; Phelan, N.; Egan, G.

    2009-01-01

    The purpose of this study was to test a new, simple method of evaluating the contrast-to-noise ratio (CNR) over the entire image field of a digital detector and to compare different mammography systems. Images were taken under clinical exposure conditions for a range of simulated breast thicknesses using poly(methyl methacrylate) (PMMA). At each PMMA thickness, a second image which included an additional 0.2-mm Al sheet was also acquired. Image processing software was used to calculate the CNR in multiple regions of interest (ROI) covering the entire area of the detector in order to obtain a 'CNR image'. Five detector types were evaluated, two CsI-αSi (GE Healthcare) flat panel systems, one αSe (Hologic) flat panel system and a two generations of scanning photon counting digital detectors (Sectra). Flat panel detectors exhibit better CNR uniformity compared with the first-generation scanning photon counting detector in terms of mean pixel value variation. However, significant improvement in CNR uniformity was observed for the next-generation scanning detector. The method proposed produces a map of the CNR and a measurement of uniformity throughout the entire image field of the detector. The application of this method enables quality control measurement of individual detectors and a comparison of detectors using different technologies. (orig.)

  5. Radiation Effects in Paediatric radiography

    International Nuclear Information System (INIS)

    Mutwasi, O.

    2006-01-01

    Diagnostic imaging has evolved from single technique to a field which we have a choice from many modalities. Some without radiation. Radiation producing modalities include plain films (low dose), Fluoroscopy (mid range dose), Computed tomography (high dose). Radiography dose can significantly be influenced in plain radiography by varying speed of screens, cassette construction and type of radiography. E.g. digital or computed. In computed or digital radiography we are no longer able to tell h igh dose b y the quality of images. The final image is by great extend a product of post processing algorithms. It's for this reasons that the basic understanding of the sensitivity and specifying of various types of examinations and of specifically radiation effects is mandatory for a paediatric imager

  6. ECFA Detector R&D Panel, Review Report

    CERN Document Server

    Abramowicz, H.; Afanaciev, K.; Aguilar, J.; Alvarez, E.; Bambade, P.; Bortko, L.; Bozovic-Jelisavcic, I.; Castro, E.; Chelkov, G.; Coca, C.; Daniluk, W.; Dragone, A.; Dumitru, L.; Elsener, K.; Emeliantchik, I.; Firu, E.; Fischer, J.; Fiutowski, T.; Ghenescu, V.; Gostkin, M.; Grzelak, G.; Haller, G.; Henschel, H.; Ignatenko, A.; Idzik, M.; Ito, K.; Kananov, S.; Kielar, E.; Kollowa, S.; Kotula, J.; Krumstein, Z.; Krupa, B.; Kulis, S.; Lange, W.; Levy, A.; Levy, I.; Linssen, L.; Lohmann, W.; Lukic, S.; Moron, J.; Moszczynski, A.; Nauenberg, U.; Neagu, A.; Novgorodova, O.; Nuiry, F.X.; Ohlerich, M.; Orlandea, M.; Oleinik, G.; Oliwa, K.; Olshevski, A.; Pandurovic, M.; Pawlik, B.; Preda, T.; Przyborowski, D.; Sato, Y.; Sadeh, I.; Sailer, A.; Schumm, B.; Schuwalow, S.; Schwartz, R.; Smiljanic, I.; Swientek, K.; Takubo, Y.; Teodorescu, E.; Wierba, W.; Yamamoto, H.; Zawiejski, L.; Zgura, T.S.; Zhang, J.

    2014-01-01

    Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10−3 at the ILC and 10−2 at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on th...

  7. Neutron radiography of Apollo ordnance

    International Nuclear Information System (INIS)

    Golliher, K.G.

    1983-01-01

    Neutron radiography played an important role in the successful Apollo missions. Neutron radiography was used, for the first time, on a production basis to examine the internal details of ordnance devices employed in the Apollo Program. Ordnance devices ranged from charges which separated the massive booster stages to those which triggered the release of re-entry parachutes. Discussed are the early developments in neutron radiography and the conversion of this infant nondestructive technology into production capabilities. (Auth.)

  8. Performance evaluation of a computed radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Roussilhe, J.; Fallet, E. [Carestream Health France, 71 - Chalon/Saone (France); Mango, St.A. [Carestream Health, Inc. Rochester, New York (United States)

    2007-07-01

    Computed radiography (CR) standards have been formalized and published in Europe and in the US. The CR system classification is defined in those standards by - minimum normalized signal-to-noise ratio (SNRN), and - maximum basic spatial resolution (SRb). Both the signal-to-noise ratio (SNR) and the contrast sensitivity of a CR system depend on the dose (exposure time and conditions) at the detector. Because of their wide dynamic range, the same storage phosphor imaging plate can qualify for all six CR system classes. The exposure characteristics from 30 to 450 kV, the contrast sensitivity, and the spatial resolution of the KODAK INDUSTREX CR Digital System have been thoroughly evaluated. This paper will present some of the factors that determine the system's spatial resolution performance. (authors)

  9. Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system

    Energy Technology Data Exchange (ETDEWEB)

    Zboray, Robert [Paul Scherrer Institute, PSI Villigen 5232 (Switzerland); Dangendorf, Volker; Bromberger, Benjamin; Tittelmeier, Kai [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig 38116 (Germany); Mor, Ilan [Soreq NRC, Yavne 81800 (Israel)

    2015-07-15

    In a previous work, we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing, significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size, and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.

  10. Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system.

    Science.gov (United States)

    Zboray, Robert; Dangendorf, Volker; Mor, Ilan; Bromberger, Benjamin; Tittelmeier, Kai

    2015-07-01

    In a previous work, we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing, significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size, and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.

  11. Noise variance analysis using a flat panel x-ray detector: A method for additive noise assessment with application to breast CT applications

    Energy Technology Data Exchange (ETDEWEB)

    Yang Kai; Huang, Shih-Ying; Packard, Nathan J.; Boone, John M. [Department of Radiology, University of California, Davis Medical Center, 4860 Y Street, Suite 3100 Ellison Building, Sacramento, California 95817 (United States); Department of Radiology, University of California, Davis Medical Center, 4860 Y Street, Suite 3100 Ellison Building, Sacramento, California 95817 (United States) and Department of Biomedical Engineering, University of California, Davis, Davis, California, 95616 (United States)

    2010-07-15

    Purpose: A simplified linear model approach was proposed to accurately model the response of a flat panel detector used for breast CT (bCT). Methods: Individual detector pixel mean and variance were measured from bCT projection images acquired both in air and with a polyethylene cylinder, with the detector operating in both fixed low gain and dynamic gain mode. Once the coefficients of the linear model are determined, the fractional additive noise can be used as a quantitative metric to evaluate the system's efficiency in utilizing x-ray photons, including the performance of different gain modes of the detector. Results: Fractional additive noise increases as the object thickness increases or as the radiation dose to the detector decreases. For bCT scan techniques on the UC Davis prototype scanner (80 kVp, 500 views total, 30 frames/s), in the low gain mode, additive noise contributes 21% of the total pixel noise variance for a 10 cm object and 44% for a 17 cm object. With the dynamic gain mode, additive noise only represents approximately 2.6% of the total pixel noise variance for a 10 cm object and 7.3% for a 17 cm object. Conclusions: The existence of the signal-independent additive noise is the primary cause for a quadratic relationship between bCT noise variance and the inverse of radiation dose at the detector. With the knowledge of the additive noise contribution to experimentally acquired images, system modifications can be made to reduce the impact of additive noise and improve the quantum noise efficiency of the bCT system.

  12. Development and investigation of a neutron radiography imaging system with a low-pressure multistep chamber

    International Nuclear Information System (INIS)

    Anisimov, Yu.S.; Chernenko, S.P.; Ivanov, A.B.; Netusil, T.; Peshekhonov, V.D.; Smykov, L.P.; Zanevsky, Yu.V.; Cisar, M.; Horacek, J.; Knourek, J.; Moucka, L.; Nezmar, L.; Pellar, L.; Pochman, J.; Schneider, Z.; Sidak, Z.; Vrba, I.; Bizek, V.; Zavadil, Z.; Beran, P.; Cerny, K.

    1988-01-01

    An imaging system of thermal neutrons for an investigation of digital neutron radiography has been developed and tested. Some characteristics obtained on a neutron radiography beam of an experimental reactor are reported. The coordinates of each event are determined in this system. After processing in a LSI 11/23 computer, a radiograph, accumulated in a histogramming memory of 64 K 16-bit words, is presented on a colour display. A 230x180 mm 2 low-pressure multistep chamber is used as a detector. Neutron conversion takes place in a 6 μm boron layer enriched to 86% in 10 B. The detection efficiency of thermal neutrons is no less than 3%. The count rate of the system reaches up to 2x10 5 events per second. A radiograph can be obtained within 10 minutes. The sensitivity of this system to gamma-background is low. One event/s is detected for a background of 1 R/h. The spatial resolution is found to be 0.7 mm (FWHM) using a cadmium knife edge. The integral nonlinearity is less than 0.4%. The possibility of using a hydrogeneous converter in this system for neutron radiography is discussed. (orig.)

  13. Image Acquisition and Quality in Digital Radiography.

    Science.gov (United States)

    Alexander, Shannon

    2016-09-01

    Medical imaging has undergone dramatic changes and technological breakthroughs since the introduction of digital radiography. This article presents information on the development of digital radiography and types of digital radiography systems. Aspects of image quality and radiation exposure control are highlighted as well. In addition, the article includes related workplace changes and medicolegal considerations in the digital radiography environment. ©2016 American Society of Radiologic Technologists.

  14. Reduction of ring artifacts in CBCT: Detection and correction of pixel gain variations in flat panel detectors

    International Nuclear Information System (INIS)

    Altunbas, Cem; Lai, Chao-Jen; Zhong, Yuncheng; Shaw, Chris C.

    2014-01-01

    Purpose: In using flat panel detectors (FPD) for cone beam computed tomography (CBCT), pixel gain variations may lead to structured nonuniformities in projections and ring artifacts in CBCT images. Such gain variations can be caused by change in detector entrance exposure levels or beam hardening, and they are not accounted by conventional flat field correction methods. In this work, the authors presented a method to identify isolated pixel clusters that exhibit gain variations and proposed a pixel gain correction (PGC) method to suppress both beam hardening and exposure level dependent gain variations. Methods: To modulate both beam spectrum and entrance exposure, flood field FPD projections were acquired using beam filters with varying thicknesses. “Ideal” pixel values were estimated by performing polynomial fits in both raw and flat field corrected projections. Residuals were calculated by taking the difference between measured and ideal pixel values to identify clustered image and FPD artifacts in flat field corrected and raw images, respectively. To correct clustered image artifacts, the ratio of ideal to measured pixel values in filtered images were utilized as pixel-specific gain correction factors, referred as PGC method, and they were tabulated as a function of pixel value in a look-up table. Results: 0.035% of detector pixels lead to clustered image artifacts in flat field corrected projections, where 80% of these pixels were traced back and linked to artifacts in the FPD. The performance of PGC method was tested in variety of imaging conditions and phantoms. The PGC method reduced clustered image artifacts and fixed pattern noise in projections, and ring artifacts in CBCT images. Conclusions: Clustered projection image artifacts that lead to ring artifacts in CBCT can be better identified with our artifact detection approach. When compared to the conventional flat field correction method, the proposed PGC method enables characterization of nonlinear

  15. Charter of good practices in industrial radiography; Charte de bonnes pratiques en radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    This document describes good practices in the field of industrial radiography. After having presented the main prevention and radiation protection principles, the actors inside and outside of the company, and actors intervening during an operation subcontracting in industrial radiography, this report analyzes the activity: prerequisites for work preparation, prevention coordination, work preparation, transportation, work achievement, return on experience. It addresses personnel training and information, and the dosimetric and medical monitoring of technicians in industrial radiography. Some aspects are addressed in appendix: principles (justification, optimization, and limitation), regulations, intervention form, exposure form, and so on

  16. Inspection reliability comparison of digital radiography, film radiography and radioscopy for inspection of Inconel welds

    International Nuclear Information System (INIS)

    Meade, W.; Kidwell, C.; Warren, G.

    2004-01-01

    Digital Radiography offers the promise of economic and environmental advantages over traditional film based inspection. Boeing Commercial Aircraft Group has an on-going effort to evaluate this emerging radiographic method for production of aerospace hardware. Included in this effort was a program to evaluate the potential for utilizing amorphous silicon based digital radiography for the inspection of inconel weldments in engine ducting. For this particular program, probability of detection (POD) studies were conducted to compare the reliability of digital radiography with the existing production processes that utilize film radiography and image-intensifier based radioscopy. Cycle time studies were also conducted to determine the potential economic benefit for switching to the new process. The methodology and findings of this comparison are presented. (author)

  17. Inspection reliability comparison of digital radiography, film radiography and radioscopy for inspection of Inconel welds

    Energy Technology Data Exchange (ETDEWEB)

    Meade, W.; Kidwell, C.; Warren, G. [Boeing Commercial Aircraft Group, Renton, Washington (United States)

    2004-07-01

    Digital Radiography offers the promise of economic and environmental advantages over traditional film based inspection. Boeing Commercial Aircraft Group has an on-going effort to evaluate this emerging radiographic method for production of aerospace hardware. Included in this effort was a program to evaluate the potential for utilizing amorphous silicon based digital radiography for the inspection of inconel weldments in engine ducting. For this particular program, probability of detection (POD) studies were conducted to compare the reliability of digital radiography with the existing production processes that utilize film radiography and image-intensifier based radioscopy. Cycle time studies were also conducted to determine the potential economic benefit for switching to the new process. The methodology and findings of this comparison are presented. (author)

  18. Flat-screen detector systems in skeletal radiology

    International Nuclear Information System (INIS)

    Grampp, S.; Czerny, C.; Krestan, C.; Henk, C.; Heiner, L.; Imhof, H.

    2003-01-01

    Implementation of flat-panel detectors and digital integration of the technique instead of the use of conventional radiographs leads to a shortening of the work process. With flat-panel technology the image production process is shortened by more than 30%. Major advantages in the implementation of integrated RIS, PACS and flat-panel detector system are increases in quality because most mistakes in picture labeling can be avoided, easier handling without the need for cassettes, and the possibility of image post-processing. The diagnostic quality of the images in the field of musculoskeletal radiology is, in comparison to conventional radiographs, at least adequate and in most cases markedly improved with a marked reduction in radiation exposure of around 30-50%. With respect to the numerous advantages of the digital techniques and especially flat-panel technology there is a very high likelihood that conventional radiographs will be substituted in the coming years, even though the cost of the new technology is currently significantly higher compared to conventional systems. (orig.) [de

  19. Simplified techniques of cerebral angiography using a mobile X-ray unit and computed radiography

    International Nuclear Information System (INIS)

    Gondo, Gakuji; Ishiwata, Yusuke; Yamashita, Toshinori; Iida, Takashi; Moro, Yutaka

    1989-01-01

    Simplified techniques of cerebral angiography using a mobile X-ray unit and computed radiography (CR) are discussed. Computed radiography is a digital radiography system in which an imaging plate is used as an X-ray detector and a final image is displayed on the film. In the angiograms performed with CR, the spatial frequency components can be enhanced for the easy analysis of fine blood vessels. Computed radiography has an automatic sensitivity and a latitude-setting mechanism, thus serving as an 'automatic camera.' This mechanism is useful for radiography with a mobile X-ray unit in hospital wards, intensive care units, or operating rooms where the appropriate setting of exposure conditions is difficult. We applied this mechanism to direct percutaneous carotid angiography and intravenous digital subtraction angiography with a mobile X-ray unit. Direct percutaneous carotid angiography using CR and a mobile X-ray unit were taken after the manual injection of a small amount of a contrast material through a fine needle. We performed direct percutaneous carotid angiography with this method 68 times on 25 cases from August 1986 to December 1987. Of the 68 angiograms, 61 were evaluated as good, compared with conventional angiography. Though the remaining seven were evaluated as poor, they were still diagnostically effective. This method is found useful for carotid angiography in emergency rooms, intensive care units, or operating rooms. Cerebral venography using CR and a mobile X-ray unit was done after the manual injection of a contrast material through the bilateral cubital veins. The cerebral venous system could be visualized from 16 to 24 seconds after the beginning of the injection of the contrast material. We performed cerebral venography with this method 14 times on six cases. These venograms were better than conventional angiograms in all cases. This method may be useful in managing patients suffering from cerebral venous thrombosis. (J.P.N.)

  20. Comparison of the efficacy of conventional radiography, digital radiography, and ultrasound in diagnosing periapical lesions.

    Science.gov (United States)

    Raghav, Namita; Reddy, Sujatha S; Giridhar, A G; Murthy, Srinivas; Yashodha Devi, B K; Santana, N; Rakesh, N; Kaushik, Atul

    2010-09-01

    The aim of this study was to evaluate the efficacy of conventional radiography, digital radiography and ultrasound imaging in diagnosing periapical lesions. Twenty-one patients aged between 15 and 45 years with well defined periapical radiolucency associated with anterior maxillary or mandibular teeth requiring endodontic surgery or extraction were selected and consented to the study. Preoperative intraoral periapical radiographs and digital images using charge-coupled device obtained by paralleling technique were assessed by 3 specialist observers who gave their diagnosis of the periapical lesions. Then ultrasound examination was performed and the images were assessed for size, contents, and vascular supply by 3 ultrasonographers. It was followed by curettage of periapical tissues to enable histopathologic investigation, which is the gold standard in diagnosis. The data were statistically analyzed using SPSS, analysis of variance, and kappa statistics. The percentage accuracy of diagnosing periapical lesions using conventional radiography was 47.6%, digital radiography 55.6%, and ultrasound 95.2%. Ultrasound had the highest sensitivity and specificity: 0.95 and 1.00, respectively. Conventional and digital radiography enable diagnosis of periapical diseases, but not their nature, whereas ultrasound provides accurate information on the pathologic nature of the lesions, which is of importance in predicting the treatment outcome. Therefore ultrasound can be used as an adjunct to conventional or digital radiography in diagnosing periapical lesions. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  1. Workshop on detectors for third-generation synchrotron sources: Proceedings

    International Nuclear Information System (INIS)

    1994-12-01

    The aims of the workshop were (1) to acquaint APS users with current R and D being carried out on detectors, (2) to identify new detector systems possible during the next five years, (3) to identify new detectors theoretically possible in the future, (4) to stimulate interactions between user groups and detector developers, and (5) to obtain recommendations from expert panels on technical issues needing resolution. Development of detectors at ESRF, Spring-8, BNL, CERN and LBL are included

  2. Workshop on detectors for third-generation synchrotron sources: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-01

    The aims of the workshop were (1) to acquaint APS users with current R and D being carried out on detectors, (2) to identify new detector systems possible during the next five years, (3) to identify new detectors theoretically possible in the future, (4) to stimulate interactions between user groups and detector developers, and (5) to obtain recommendations from expert panels on technical issues needing resolution. Development of detectors at ESRF, Spring-8, BNL, CERN and LBL are included.

  3. Neutron radiography by using JSW baby cyclotron

    International Nuclear Information System (INIS)

    Toda, Yojiro

    1995-01-01

    At present, JSW baby cyclotrons are mostly used for the production of the radioisotopes for medical use. The attempt to use this baby cyclotron for neutron radiography began already in 1981. The feasibility of the neutron radiography for the explosives in metallic cases which are used for H1 rockets was investigated. In 1983, it was shown that the neutron radiography by using the baby cyclotron in Muroran Works, Japan Steel Works, Ltd. was able to be carried out as a routine work. Since then, the nondestructive inspection by neutron radiography has been performed for rocket pyrotechnic articles, and contributed to heighten their reliability. Further, the radiography by using fast neutrons was developed and put to practical use for recent large H2 rockets. The JSW baby cyclotron BC 168 which has been used for neutron radiography can accelerate 16 MeV protons or 8 MeV deuterons up to 50 μA. The principle of thermal neutron radiography is the generation of fast neutrons by irradiating a Be target with the proton beam accelerated by a baby cyclotron, the moderation of the fast neutrons, the formation of the thermal neutron flux of uniform distribution with a collimator, the thermal neutron flux hitting the Gd plate in a film cassette through an object, and the exposure of an X-ray film to electrons from the Gd plate. Fast neutron radiography apparatus, and commercial neutron radiography are described. (K.I.)

  4. Digital image processing in neutron radiography

    International Nuclear Information System (INIS)

    Koerner, S.

    2000-11-01

    Neutron radiography is a method for the visualization of the macroscopic inner-structure and material distributions of various samples. The basic experimental arrangement consists of a neutron source, a collimator functioning as beam formatting assembly and of a plane position sensitive integrating detector. The object is placed between the collimator exit and the detector, which records a two dimensional image. This image contains information about the composition and structure of the sample-interior, as a result of the interaction of neutrons by penetrating matter. Due to rapid developments of detector and computer technology as well as deployments in the field of digital image processing, new technologies are nowadays available which have the potential to improve the performance of neutron radiographic investigations enormously. Therefore, the aim of this work was to develop a state-of-the art digital imaging device, suitable for the two neutron radiography stations located at the 250 kW TRIGA Mark II reactor at the Atominstitut der Oesterreichischen Universitaeten and furthermore, to identify and develop two and three dimensional digital image processing methods suitable for neutron radiographic and tomographic applications, and to implement and optimize them within data processing strategies. The first step was the development of a new imaging device fulfilling the requirements of a high reproducibility, easy handling, high spatial resolution, a large dynamic range, high efficiency and a good linearity. The detector output should be inherently digitized. The key components of the detector system selected on the basis of these requirements consist of a neutron sensitive scintillator screen, a CCD-camera and a mirror to reflect the light emitted by the scintillator to the CCD-camera. This detector design enables to place the camera out of the direct neutron beam. The whole assembly is placed in a light shielded aluminum box. The camera is controlled by a

  5. Digital image processing in neutron radiography

    International Nuclear Information System (INIS)

    Koerner, S.

    2000-11-01

    Neutron radiography is a method for the visualization of the macroscopic inner-structure and material distributions of various materials. The basic experimental arrangement consists of a neutron source, a collimator functioning as beam formatting assembly and of a plane position sensitive integrating detector. The object is placed between the collimator exit and the detector, which records a two dimensional image. This image contains information about the composition and structure of the sample-interior, as a result of the interaction of neutrons by penetrating matter. Due to rapid developments of detector and computer technology as well as deployments in the field of digital image processing, new technologies are nowadays available which have the potential to improve the performance of neutron radiographic investigations enormously. Therefore, the aim of this work was to develop a state-of-the art digital imaging device, suitable for the two neutron radiography stations located at the 250 kW TRIGA Mark II reactor at the Atominstitut der Oesterreichischen Universitaeten and furthermore, to identify and develop two and three dimensional digital image processing methods suitable for neutron radiographic and tomographic applications, and to implement and optimize them within data processing strategies. The first step was the development of a new imaging device fulfilling the requirements of a high reproducibility, easy handling, high spatial resolution, a large dynamic range, high efficiency and a good linearity. The detector output should be inherently digitized. The key components of the detector system selected on the basis of these requirements consist of a neutron sensitive scintillator screen, a CCD-camera and a mirror to reflect the light emitted by the scintillator to the CCD-camera. This detector design enables to place the camera out of the direct neutron beam. The whole assembly is placed in a light shielded aluminum box. The camera is controlled by a

  6. New medical application: nuclear scattering radiography

    International Nuclear Information System (INIS)

    Saudinos, J.

    1977-01-01

    Nuclear scattering of 1 GeV protons is used to obtain three dimensional radiographies with a volume resolution of about 1 mm 3 . The information is different from the one given by X-ray radiographies and in particular one may get radiographies of the hydrogen included in objects. Results on a vertebral column and a 'sella turcica' are presented [fr

  7. Radiation Safety in Industrial Radiography. Specific Safety Guide

    International Nuclear Information System (INIS)

    2011-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  8. Workshop on industrial isotope radiography: Programme and lectures

    International Nuclear Information System (INIS)

    1979-01-01

    The booklet contains the texts of lectures delivered in the Workshop on Industrial Radiography held at Bombay during 24-25 July 1979. The lectures cover some topics of relevance to industrial radiography. The topics are radiation protection and legislative aspects in industrial radiography; problems in field radiography in fertilizer industry, petrochemical industry and heavy engineering industry; occupational exposures in industrial radiography; and a review of the progress and recent trends in industrial radiographic techniques and equipment. (M.G.B.)

  9. Digital Radiography in Kenya today

    International Nuclear Information System (INIS)

    Omenta, E.N.

    2006-01-01

    Its nearly one year and a half since digital imaging/radiography was introduced in Kenya mainly in Nairobi. the technology is becoming an increasingly effective and acceptable modality of producing radiographs from the traditional conventional radiography in use to date. the digital radiography offers numerous advantages that have been noted for the short period over the conventional way. For instance radiographs are produced in real time (less than 3 minutes), by so doing the technology has eliminated the wait for the processing period. the radiation exposure to the patient under the radiological examination is reduced as much as 90% from the traditional conventional film taking. The cost, labour and record-keeping necessary to maintain a chemical processor and darkroom operations are as well eliminated. The cost of purchasing and disposing of film wastes/darkroom processing chemicals, which are environmentally hazardous, also become unnecessary.digital radiography technology makes the digital images comparable to other images on the screen at that instant making both the patient and the clinician easily access images when needed. digital receptors have also replaced the cassette containing intensifying screens and film that is used in conventional radiography

  10. Diagnostic radiography: A study in distancing

    International Nuclear Information System (INIS)

    Reeves, Pauline J.; Decker, Sola

    2012-01-01

    Aims: This article aims to explore the ways in which diagnostic radiographers use distancing as a tool for emotional management in radiography practice. Methods: This review utilises data from oral history interviews undertaken as part of a larger study documenting the oral history of the diagnostic radiography profession in the United Kingdom as recounted by 24 participants. Results: The results are presented as illustrative of various aspects of the role of the diagnostic radiographer including the initial choice of diagnostic radiography as a profession, the endemic use of particular terminology, the nature of the encounter in diagnostic radiography (including that of sectional imaging) and whether the role is really patient-centred. Conclusions: The article concludes by suggesting that distancing from the patient is mediated by the need for physical touch in order to position the patient for radiography and also makes the suggestion that those opting for diagnostic radiography as a career may do so because they want a profession which is more distanced from the patient and that, even where this is not the case initially, individuals are socialised into adopting the ‘feeling rules’ of the profession. The article concludes by outlining potential areas for further research.

  11. SU-E-J-158: Experimental Investigation of Proton Radiography Based On Time-Resolved Dose Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Testa, M; Paganetti, H; Lu, H-M [Massachusetts General Hospital ' Harvard Medical School, Boston, MA (United States); Doolan, P [University College London (United Kingdom); H, Bentefour E [IBA, Warrenville, IL (United States)

    2014-06-01

    Purpose: To use proton radiography for i) in-vivo range verification of the brain fields of medulloblastoma patients in order to reduce the exit dose to the cranial skin and thus the risk of permanent alopecia; ii) for performing patient specific optimization of the calibration from CT-Hounsfield units to proton relative stopping power in order to minimize uncertainties of proton rang Methods: We developed and tested a prototype proton radiography system based on a single-plane scintillation screen coupled with a fast CCD camera (1ms sampling rate, 0.29x0.29 mm{sup 2} pixel size, 30×30 cm{sup 2} field of view). The method is based on the principle that, for passively scattered beams, the radiological depth of any point in the plateau of a spread-out Bragg-Peak (SOBP) can be inferred from the time-pattern of the dose rate measurements. We performed detector characterization measurements using complex-shape homogeneous phantoms and an Alderson phanto Results: Detector characterization tests confirmed the robustness of the technique. The results of the phantom measurements are encouraging in terms of achievable accuracy of the water equivalent thickness. A technique to minimize the degradation of spatial resolution due to multiple Coulomb scattering is discussed. Our novel radiographic technique is rapid (100 ms) and simultaneous over the whole field. The dose required to produce one radiograph, with the current settings, is ∼3 cG Conclusion: The results obtained with this simple and innovative radiography method are promising and motivate further development of technique. The system requires only a single-plane 2D dosimeter and it uses the clinical beam for a fraction of second with low dose to the patient.

  12. Design of parallel dual-energy X-ray beam and its performance for security radiography

    International Nuclear Information System (INIS)

    Kim, Kwang Hyun; Myoung, Sung Min; Chung, Yong Hyun

    2011-01-01

    A new concept of dual-energy X-ray beam generation and acquisition of dual-energy security radiography is proposed. Erbium (Er) and rhodium (Rh) with a copper filter were positioned in front of X-ray tube to generate low- and high-energy X-ray spectra. Low- and high-energy X-rays were guided to separately enter into two parallel detectors. Monte Carlo code of MCNPX was used to derive an optimum thickness of each filter for improved dual X-ray image quality. It was desired to provide separation ability between organic and inorganic matters for the condition of 140 kVp/0.8 mA as used in the security application. Acquired dual-energy X-ray beams were evaluated by the dual-energy Z-map yielding enhanced performance compared with a commercial dual-energy detector. A collimator for the parallel dual-energy X-ray beam was designed to minimize X-ray beam interference between low- and high-energy parallel beams for 500 mm source-to-detector distance.

  13. Functioning of industrial radiography services

    International Nuclear Information System (INIS)

    Alves, R.N.; Costa, H.M. da; Bianchini, F.G.; Arrieta, L.A.I.

    1988-12-01

    The objective of this norm is establish the necessary requirements for the functioning of industrial radiography services, as well as the procedures for acquisition and transfer of radioactive sources and/or X-ray equipments used in industrial radiography [pt

  14. Advancements of floating strip Micromegas detectors for medical imaging applications

    Energy Technology Data Exchange (ETDEWEB)

    Klitzner, Felix; Biebel, Otmar; Bortfeldt, Jonathan; Flierl, Bernhard [LS Schaile, LMU Muenchen (Germany); Magallanes, Lorena [LS Parodi, LMU Muenchen (Germany); Universitaetsklinikum Heidelberg (Germany); Parodi, Katia [LS Parodi, LMU Muenchen (Germany); Heidelberger Ionenstrahl Therapiezentrum (Germany); Voss, Bernd [Gesellschaft fuer Schwerionenforschung, Darmstadt (Germany)

    2016-07-01

    Floating strip Micromegas have proven to be high-rate capable tracking detectors with excellent spatial and temporal resolution for particle fluxes up to 7 MHz/cm{sup 2}. To further increase the high-rate capability a Ne:CF{sub 4} 86:14 vol.% gas mixture has been used as detector gas. We present results from measurements with a seven detector system consisting of six low material budget floating strip Micromegas, a GEM detector and a scintillator based particle range telescope. The gaseous and the scintillation detectors were read out with APV25 frontend boards, allowing for single strip readout with pulse height and timing information. A two-dimensional readout anode for floating strip Micromegas has been tested for the first time. The Micromegas detectors were operated with minimal additional drift field, which significantly improves the timing resolution and also the spatial resolution for inclined tracks. We discuss the detector performance in high-rate carbon and proton beams at the Heidelberg Ion Beam Therapy Center (HIT) and present radiographies of phantoms, acquired with the system.

  15. Are radiography lecturers, leaders?

    International Nuclear Information System (INIS)

    Hendry, Julie Anne

    2013-01-01

    This review article aims to explore the concept of radiography lecturers acting as leaders to their student followers. Through a brief review of the literature, a definition of leadership is suggested and some leadership theories explored. The path-goal theory, leader–member exchange theory and the contemporary theory of transformational leadership are examined more closely. Links between lecturer-leader behaviour and student motivation and learning are tentatively suggested with transformational leadership appearing to offer the optimal leadership style for lecturers to adopt. The paucity of literature relating directly to radiography is acknowledged and areas for further research are suggested. The article concludes with some of the author's practical ideas for incorporating transformational leadership styles and behaviours into radiography education today

  16. Computed radiography in paediatrics

    International Nuclear Information System (INIS)

    Kelly, C.

    1996-01-01

    Computed radiography has also been called storage phosphor technology, digital luminescence radiography and scintillation phosphor technology, since it relies on phosphor imaging plate as an alternative to screen-film. One of the major advantages in the use of computed radiography (CR) is the consistent image quality independence of the radiographer and exposure used. And secondly a marked reduction in the need for repeat films was achieved and thus a decrease in dose to the patient. In some cases, dose was able to be reduced further due to the fact that the plates respond to lower doses and still provide adequate image quality. Digitalising the Cr image allows it to be transmitted to an imaging console. The images can then be stored on optical disc. 7 refs

  17. Measurement of joint kinematics using a conventional clinical single-perspective flat-panel radiography system

    International Nuclear Information System (INIS)

    Seslija, Petar; Teeter, Matthew G.; Yuan Xunhua; Naudie, Douglas D. R.; Bourne, Robert B.; MacDonald, Steven J.; Peters, Terry M.; Holdsworth, David W.

    2012-01-01

    Purpose: The ability to accurately measure joint kinematics is an important tool in studying both normal joint function and pathologies associated with injury and disease. The purpose of this study is to evaluate the efficacy, accuracy, precision, and clinical safety of measuring 3D joint motion using a conventional flat-panel radiography system prior to its application in an in vivo study. Methods: An automated, image-based tracking algorithm was implemented to measure the three-dimensional pose of a sparse object from a two-dimensional radiographic projection. The algorithm was tested to determine its efficiency and failure rate, defined as the number of image frames where automated tracking failed, or required user intervention. The accuracy and precision of measuring three-dimensional motion were assessed using a robotic controlled, tibiofemoral knee phantom programmed to mimic a subject with a total knee replacement performing a stair ascent activity. Accuracy was assessed by comparing the measurements of the single-plane radiographic tracking technique to those of an optical tracking system, and quantified by the measurement discrepancy between the two systems using the Bland–Altman technique. Precision was assessed through a series of repeated measurements of the tibiofemoral kinematics, and was quantified using the across-trial deviations of the repeated kinematic measurements. The safety of the imaging procedure was assessed by measuring the effective dose of ionizing radiation associated with the x-ray exposures, and analyzing its relative risk to a human subject. Results: The automated tracking algorithm displayed a failure rate of 2% and achieved an average computational throughput of 8 image frames/s. Mean differences between the radiographic and optical measurements for translations and rotations were less than 0.08 mm and 0.07° in-plane, and 0.24 mm and 0.6° out-of-plane. The repeatability of kinematics measurements performed using the

  18. Industrial radiography techniques and their applications

    International Nuclear Information System (INIS)

    Wamorkar, R.R.

    1981-01-01

    Various aspects of industrial radiography are discussed. These include: radiation sources, geometrical unsharpness of image, radiation attenuation in the specimen, radiation effect of film, types of film, intensifying screens, exposure time calculations, source to film distance and sensivitity. Radiography techniques for examination of welded joints on flat plate and pipes or cylindrical objects, and castings are indicated. Applications of radiography in various industries are mentioned. (M.G.B.)

  19. Development of a proton Computed Tomography Detector System

    Energy Technology Data Exchange (ETDEWEB)

    Naimuddin, Md. [Delhi U.; Coutrakon, G. [Northern Illinois U.; Blazey, G. [Northern Illinois U.; Boi, S. [Northern Illinois U.; Dyshkant, A. [Northern Illinois U.; Erdelyi, B. [Northern Illinois U.; Hedin, D. [Northern Illinois U.; Johnson, E. [Northern Illinois U.; Krider, J. [Northern Illinois U.; Rukalin, V. [Northern Illinois U.; Uzunyan, S. A. [Northern Illinois U.; Zutshi, V. [Northern Illinois U.; Fordt, R. [Fermilab; Sellberg, G. [Fermilab; Rauch, J. E. [Fermilab; Roman, M. [Fermilab; Rubinov, P. [Fermilab; Wilson, P. [Fermilab

    2016-02-04

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  20. Vertebral Fracture Assessment in Supine Position : Comparison by Using Conventional Semiquantitative Radiography and Visual Radiography

    NARCIS (Netherlands)

    Hospers, Ilone C.; van der Laan, Johan G.; Zeebregts, Clark J.; Nieboer, Patrick; Wolffenbuttel, Bruce H. R.; Dierckx, Rudi A.; Kreeftenberg, Herman G.; Jager, Pieter L.; Slart, Riemer H. J. A.

    Purpose: To retrospectively evaluate the accuracy of vertebral fracture assessment (VFA) performed with the patient in the supine position and conventional semiquantitative radiography of the spine by using conventional visual radiography of the spine as the reference standard. Materials and

  1. Radiography - A new field among health sciences in Finland

    International Nuclear Information System (INIS)

    Pakarinen, Ritva; Jussila, Aino-Liisa

    2007-01-01

    In order to secure high quality X-ray services and efficient operation of clinical radiography, a study programme in radiography science was implemented at the University of Oulu in 1999. The need for a specific field of science has emerged as a result of social changes, such as the aging population, and the fast development of technology that has caused significant changes in the radiological working environment and clinical radiography. A need for a new, research-based informational foundation of clinical radiography is the basis for the programme. As service producers, radiographers need vast knowledge as well as specific expertise. The research object of radiography science is clinical radiography. If it was studied from the viewpoint of other sciences, the key professional skills of a radiographer would remain unexplored. Implementing an own field of science has enabled the development of radiography from its own bases. Basic research in the field is represented, for example, by the concept analysis of radiography in health sciences. Radiography science should produce research results for both clinical radiography and the instruction of radiography. So far, research results have dealt with the professional decision-making of a radiographer, the influences of computer technology on a radiographer's work and measuring the radiation exposure of a population

  2. Comparison of image quality among three x-ray systems for chest radiography: first step in optimisation

    International Nuclear Information System (INIS)

    Nocetti, D.; Ubeda, C.; Calcagno, S.; Acevedo, J.; Pardo, D.

    2015-01-01

    The aim of this study was to compare the performance of three digital X-ray systems [one flat-panel (DR) and two computed radiography (CR)] for chest radiography in terms of the entrance surface air kerma (ESAK) delivered to a polymethyl methacrylate phantom of 20 cm (equivalent to an adult patient) and image quality through of numerical evaluations using a test object (TO). The tube charge applied was ranged from 0.6 to 32 mAs, to a fixed tension of 125 kVp. The DR system presented the highest mean values of ESAK (615.9 μGy) along with the highest signal-to-noise ratio values, whereas CR systems showed a better high-contrast spatial resolution. Differences were statistically significant in both cases regarding the tube charge used. Thus, this parameter should be mainly considered to optimise the radiological protection through exposure settings selected. This survey represents the first effort to achieve optimisation in digital radiology for Chile. (authors)

  3. A Neutron Radiography System for Field Use

    Science.gov (United States)

    1989-06-01

    provoked a major renewal of interest in neutron radiography because it promises to bring neutron radiography to the workplace , a convenience provided...II I~F I C II i IiH i ii MTL TR 89-52 I-AD A NEUTRON RADIOGRAPHY SYSTEM N FOR FIELD USE e~m JOHN J. ANTAL and ALFRED S. MAROTTA, and LOUIS J. FARESE...COVERED A NEUTRON RADIOGRAPHY SYSTEM FOR FIELD USE Final Report 6. PERFORMING OR1. REPORT NUMBER 7. AUTHOR(s) S. CONTRACT OR GRANT NUMBER(s) John J

  4. SU-D-204-05: Quantitative Comparison of a High Resolution Micro-Angiographic Fluoroscopic (MAF) Detector with a Standard Flat Panel Detector (FPD) Using the New Metric of Generalized Measured Relative Object Detectability (GM-ROD)

    Energy Technology Data Exchange (ETDEWEB)

    Russ, M; Ionita, C; Bednarek, D; Rudin, S [Toshiba Stroke and Vascular Research Center, University at Buffalo (SUNY), Buffalo, NY (United States)

    2015-06-15

    Purpose: In endovascular image-guided neuro-interventions, visualization of fine detail is paramount. For example, the ability of the interventionist to visualize the stent struts depends heavily on the x-ray imaging detector performance. Methods: A study to examine the relative performance of the high resolution MAF-CMOS (pixel size 75µm, Nyquist frequency 6.6 cycles/mm) and a standard Flat Panel Detector (pixel size 194µm, Nyquist frequency 2.5 cycles/mm) detectors in imaging a neuro stent was done using the Generalized Measured Relative Object Detectability (GM-ROD) metric. Low quantum noise images of a deployed stent were obtained by averaging 95 frames obtained by both detectors without changing other exposure or geometric parameters. The square of the Fourier transform of each image is taken and divided by the generalized normalized noise power spectrum to give an effective measured task-specific signal-to-noise ratio. This expression is then integrated from 0 to each of the detector’s Nyquist frequencies, and the GM-ROD value is determined by taking a ratio of the integrals for the MAF-CMOS to that of the FPD. The lower bound of integration can be varied to emphasize high frequencies in the detector comparisons. Results: The MAF-CMOS detector exhibits vastly superior performance over the FPD when integrating over all frequencies, yielding a GM-ROD value of 63.1. The lower bound of integration was stepped up in increments of 0.5 cycles/mm for higher frequency comparisons. As the lower bound increased, the GM-ROD value was augmented, reflecting the superior performance of the MAF-CMOS in the high frequency regime. Conclusion: GM-ROD is a versatile metric that can provide quantitative detector and task dependent comparisons that can be used as a basis for detector selection. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

  5. Gamma radiography and its technological application; Gammagraphie et techniques annexes

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1962-07-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  6. X-ray fluorescence and computed radiography analysis of a famous brazilian painting from XIX century

    International Nuclear Information System (INIS)

    Calza, Cristiane; Oliveira, Davi F.; Rocha, Henrique S.; Lopes, Ricardo Tadeu

    2009-01-01

    This work used Energy Dispersive X-Ray Fluorescence (EDXRF) and Computed Radiography (CR) to evaluate the general conditions of the painting 'Gioventu' (Eliseu Visconti, 1898), identifying possible problems, areas that revealed signs of previous retouchings and the pigments used by the artist. EDXRF measurements were carried out with a portable system consisting of an X-ray tube Oxford TF3005 with W anode, operating at 25 kV and 100 μA, and a Si-PIN XR-100CR detector from Amptek. Several spectra were obtained in each color, with an acquisition time of 300 s and a beam collimation of 2 mm. The spectra were analyzed using the software QXAS-AXIL (IAEA). The results revealed that the drawings were made over a preparatory layer of lead white. Some pigments identified were: yellow, red and brown ochre; umbra; vermilion; cobalt blue; etc. The experimental setup used in the CR analysis consisted of an Oxford X-ray source, operating at 50 kV and 200 μA, placed at 85 cm from the painting, a GE CR 50P portable computed radiography scanner and a Fuji imaging plate detector. The exposure time was 600 s. The radiographic images revealed that the painting was in a good state of conservation and also a complete composition hidden underneath the visible paint layer.(author)

  7. X-ray fluorescence and computed radiography analysis of a famous brazilian painting from XIX century

    Energy Technology Data Exchange (ETDEWEB)

    Calza, Cristiane; Oliveira, Davi F.; Rocha, Henrique S.; Lopes, Ricardo Tadeu [Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentacao Nuclear], e-mail: ccalza@lin.ufrj.br; Pedreira, Andrea [Museu Nacional de Belas Artes, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This work used Energy Dispersive X-Ray Fluorescence (EDXRF) and Computed Radiography (CR) to evaluate the general conditions of the painting 'Gioventu' (Eliseu Visconti, 1898), identifying possible problems, areas that revealed signs of previous retouchings and the pigments used by the artist. EDXRF measurements were carried out with a portable system consisting of an X-ray tube Oxford TF3005 with W anode, operating at 25 kV and 100 {mu}A, and a Si-PIN XR-100CR detector from Amptek. Several spectra were obtained in each color, with an acquisition time of 300 s and a beam collimation of 2 mm. The spectra were analyzed using the software QXAS-AXIL (IAEA). The results revealed that the drawings were made over a preparatory layer of lead white. Some pigments identified were: yellow, red and brown ochre; umbra; vermilion; cobalt blue; etc. The experimental setup used in the CR analysis consisted of an Oxford X-ray source, operating at 50 kV and 200 {mu}A, placed at 85 cm from the painting, a GE CR 50P portable computed radiography scanner and a Fuji imaging plate detector. The exposure time was 600 s. The radiographic images revealed that the painting was in a good state of conservation and also a complete composition hidden underneath the visible paint layer.(author)

  8. Broadening the radiography spectrum

    International Nuclear Information System (INIS)

    Waswa, L.; Mutwasi, O.; Kioko, J.

    2006-05-01

    The text discuses the mammography in breast screening and evaluation of breast cancer; Small parts ultrasounds at plaza imaging solutions; role of a Radiographer in mammography-new perspective; Medical imaging education in africa; Caring for the paediatric patient as to broaden radiotherapy spectrum; Problems and challenges in care for children undergoing radiotherapy; Paediatric radiotherapy, management and side effects; The principles of pattern recognition of skeletal structures; the place of distance learning education in broadening the radiography spectrum; the curriculum and budgeting image; sonographer's guide; Computed radiography- X-Ray with vision; digital Radiography in Kenya today; Particle Therapy at Ithemba Labs; The role of lung perfusion and ventilation study in the evaluation of the pulmonary embolism and lastly, an overview of Head and neck treatment at Kenyatta National hospital radiotherapy

  9. Digital radiography exposure indices: A review

    International Nuclear Information System (INIS)

    Mothiram, Ursula; Brennan, Patrick C; Lewis, Sarah J; Moran, Bernadette; Robinson, John

    2014-01-01

    Digital radiography (DR) technologies have the advantage of a wide dynamic range compared to their film-screen predecessors, however, this poses a potential for increased patient exposure if left unchecked. Manufacturers have developed the exposure index (EI) to counter this, which provides radiographers with feedback on the exposure reaching the detector. As these EIs were manufacturer-specific, a wide variety of EIs existed. To offset this, the international standardised EI has been developed by the International Electrotechnical Commission (IEC) and the American Association of Physicists in Medicine (AAPM). The purpose of this article is to explore the current literature relating to EIs, beginning with the historical development of the EI, the development of the standardised EI and an exploration of common themes and studies as evidenced in the research literature. It is anticipated that this review will provide radiographers with a useful guide to understanding EIs, their application in clinical practice, limitations and suggestions for further research

  10. High energy neutron radiography

    International Nuclear Information System (INIS)

    Gavron, A.; Morley, K.; Morris, C.; Seestrom, S.; Ullmann, J.; Yates, G.; Zumbro, J.

    1996-01-01

    High-energy spallation neutron sources are now being considered in the US and elsewhere as a replacement for neutron beams produced by reactors. High-energy and high intensity neutron beams, produced by unmoderated spallation sources, open potential new vistas of neutron radiography. The authors discuss the basic advantages and disadvantages of high-energy neutron radiography, and consider some experimental results obtained at the Weapons Neutron Research (WNR) facility at Los Alamos

  11. WE-G-209-01: Digital Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, B. [Mayo Clinic (United States)

    2016-06-15

    Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

  12. Neutron radiography at the HFR Petten compilation of HFR Petten contributions to the second world conference on neutron radiography

    International Nuclear Information System (INIS)

    Markgraf, J.W.F.

    1986-01-01

    This booklet summarizes the six papers on neutron radiography activities at the Petten High Flux Reactor (HFR), presented at the Second World Conference on neutron radiography, held in June 1986 in Paris, France. The conference was organized by the French CEA and COFREND, and JRC Petten, HFR Division, with joint sponsorship of the national societies on Non-Destructive Testing (NDT) from the Federal Republic of Germany, United Kingdom, Japan and the United States. The Petten papers are concerned with: (i) the work of the Neutron Radiography Working Group (NRWG), an expert group operating under the auspices of the Commission of the European Communities represented by JRC Petten, HFR Division; (ii) applications of neutron radiography in research programmes performed at HFR; (iii) neutron radiography facilities at HFR; and (iv) image evaluation techniques

  13. A range of equipment for dental radiography

    International Nuclear Information System (INIS)

    Bergman, G.P.M.; Clement, S.L.

    1980-01-01

    A brief review of the history of dental radiography is followed by a description of the latest Philips equipment, ranging from compact units for intra-oral radiography to advanced systems for panoramic techniques and skull radiography. The advantages of automatic exposure control and automatic film processing are also discussed. In conclusion, some probable future trends are forecast. (Auth.)

  14. Dosimetry and optimization in digital radiography based on the detail contrast resolution

    Energy Technology Data Exchange (ETDEWEB)

    Gomes B, W. O. [Instituto Federal da Bahia, Rua Emidio dos Santos s/n, Barbalho 40301-015, Salvador de Bahia (Brazil); Gomes de C, A., E-mail: wilsonottobatista@gmail.com [Secretaria de Saude do Estado da Bahia, Salvador de Bahia (Brazil)

    2016-10-15

    In digital radiography, computed radiography systems (CR) and portable panels a-Si (DR) are adapted to equipment previously used for the system screen / film. Therefore it maintains the characteristics as grid, filtration, yield, etc. Otherwise, the systems dedicated with a-Si panels (DR), are designed to operate with these image receptors. The ability to detect in low contrast details is reduced for all systems with increasing ratio of scattered radiation / primary radiation. In this context there is a need to acquire experience and adjust exposure protocols to ensure the quality of the image with maintaining kerma values in the surface as low as possible. The contrast resolution is defined as the ability of the system to distinguish similar degrees of attenuation of the object and is a parameter used to maintain the quality index and comparison between different systems. The protocols were: chest (90 and 102 kV with the range of 2-20 m As) and abdomen (80 kV in the range of 10-80 m As). Kerma values were evaluated with a solid state sensors. Based on analysis of these curves C-D, which identified the technique would imply a lower kerma input surface while maintaining image quality from the point of view of contrast-detail resolution. The results show that the IQFinv varies little throughout the range of m As, while the value of kerma varies linearly with in m As. Also, the complete analysis of the curves indicate that there was an increase in the definition of detail with increasing m As. The conclusion is that, in the transition phase of the new receivers are needed to assess and adjust practiced protocols to ensure the quality index of the image taking into account aspects of radiation protection of the patient. And even with digital technology, good radiographic technique should be practiced. (Author)

  15. Imaging of bone tumors: evaluation of direct magnification radiography

    International Nuclear Information System (INIS)

    Link, T.M.; Hillmann, A.; Erlemann, R.; Groenefeld, A.; Haeussler, M.; Heppe, A.E.; Vestring, T.; Peters, P.E.

    1996-01-01

    Objective. To evaluate the potentials of magnification radiography as compared with conventional radiography in diagnosing bone tumors. Design and patients. Sixty-two patients with primary bone tumors and tumorlike lesions underwent radiography with both conventional (non-magnified) and magnification (fivefold) techniques. All radiographs were analyzed by four radiologists and the findings correlated with the histopathology findings. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 μm. Digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Results. The diagnosis of benign and malignant lesions as well as the individual tumor diagnosis were determined with higher accuracy using magnification compared with conventional radiography (88% vs 75% and 71% vs 52%, p<0.01). Margins of destruction, periosteal reactions and matrix patterns were evaluated with higher certainty by all of the radiologists (p<0.01). Conclusion. Magnification radiography may improve the evaluation and diagnosis of bone tumors. (orig.). With 6 tabs

  16. Industrial Radiography | Radiation Protection | US EPA

    Science.gov (United States)

    2017-08-07

    Manufacturers use a method called industrial radiography to check for cracks or flaws in materials. Radiation is used in industrial radiography to show problems not visible from the outside without damaging the material.

  17. Modeling and design of X-rays bidimensional detectors; Modelagem e projeto de detectores bidimensionais para radiacao-X

    Energy Technology Data Exchange (ETDEWEB)

    Quisbert, Elmer Paz Alcon

    2000-03-01

    In this work has been developed the scintillating fiber optic and semiconductor devices based 2-D detector design, modeling and performance evaluation using Monte Carlo methods, for high X-ray energy range (10-140 kV) radiography and tomography applications. These processes allowed us, also, the imaging system parameters and components optimization and appropriate detector design. The model estimated the detectors performance parameters (DQE, MTF and SNR), and radiation risk (in terms of mean absorbed dose in the patient) and to show up how the sequence of physical processes in X-ray detection influence the performance of this imaging PFOC detectors. In this way, the modeling of the detector includes the statistics of the spatial distribution of absorbed X-rays and of X-ray to light conversion, its transmission, and the light quanta conversion into electrons. Also contributions to noise from the detection system chain is included, mainly the CCD detector ambient noise. Performance prediction, based on calculation taken from simulations, illustrates how such detectors meet the exacting requirements of some medical and industrial applications. Also, it is envisaged that our modeling procedure of the imaging system will be suitable not only for investigating how the system components should be best designed but for CT and RD system performance prediction. The powerful techniques would enable us to give advice for future development, in this field, in search of more dose-efficient imaging systems. (author)

  18. Artifacts in digital radiography

    International Nuclear Information System (INIS)

    Min, Jung Whan; Kim, Jung Min; Jeong, Hoi Woun

    2015-01-01

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments

  19. Artifacts in digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Whan [Dept. of Radiological Technology, Shin Gu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Technology, Korea University, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Beakseok Culture University, Cheonan (Korea, Republic of)

    2015-12-15

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments.

  20. Neutron induced electron radiography

    International Nuclear Information System (INIS)

    Andrade, Marcos Leandro Garcia

    2008-01-01

    In the present paper a new radiography technique, the 'Neutron Induced Electron Radiography' - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole no. 8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 μm in 24 μm of aluminum at a resolution of 32 μm. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization. (author)

  1. The advantages of digital radiography in department of radiology

    International Nuclear Information System (INIS)

    Mao Lijuan; Luo Xiaomei; Wu Tengfang

    2009-01-01

    Objective: To investigate the advantages of digital radiography in department of radiology by comparing digital radiography with common radiography. Methods: Test card was used for testing the spatial resolution of DR and common radiography. 1000 films of chest by DR and 1000 films of chest by common radiography were compared in image quality, dose of radiation, the rate of waste film, and the advantages of DR was analyzed. Results: Compared to common radiography, DR had a high sensitivity, high DQE (quantum detection efficiency), high spatial resolution and density resolution. The speed of acquisition and X-ray conversion efficiency were fast. The function of post-processing was strong and the rate of disease detection was high. Conclusion: DR is better than common radiography in all respects, it will be widely applied. (authors)

  2. Chest radiography after minor chest trauma

    Energy Technology Data Exchange (ETDEWEB)

    Rossen, B.; Laursen, N.O.; Just, S.

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma.

  3. Chest radiography after minor chest trauma

    International Nuclear Information System (INIS)

    Rossen, B.; Laursen, N.O.; Just, S.

    1987-01-01

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma. (orig.)

  4. Representability of metastatic bone lesions in magnification radiography

    International Nuclear Information System (INIS)

    Togawa, Takashi

    1981-01-01

    Magnification radiography, bone scintigraphy, and normal roentgenography were performed on patients with malignant tumors to detect their bone metastases, and from the results obtained, these diagnostic procedures were evaluated for the detectability and representability of metastatic bone lesions. Bone scan and normal roentgenography were performed on 90 metastatic bone lesions in 37 patients, and magnification radiography was done on 14 bone lesions noted in 10 of the 37 and another with benign osseous change. Among the three, bone scintigraphy was best, and magnification radiography and normal roentgenography did not differ significantly in detectability. In magnification radiography, some metastatic bone lesions were represented more clearly than by normal roentgeography, but some were not. As regards the representability of the ribs, magnification radiography was very useful. One case of bone destruction was detected by magnification radiography, but not by normal roentgenography. (author)

  5. Process waste assessment for the Radiography Laboratory

    International Nuclear Information System (INIS)

    Phillips, N.M.

    1994-07-01

    This Process Waste Assessment was conducted to evaluate the Radiography Laboratory, located in Building 923. It documents the processes, identifies the hazardous chemical waste streams generated by these processes, recommends possible ways to minimize waste, and serves as a reference for future assessments of this facility. The Radiography Laboratory provides film radiography or radioscopy (electronic imaging) of weapon and nonweapon components. The Radiography Laboratory has six x-ray machines and one gamma ray source. It also has several other sealed beta- and gamma-ray isotope sources of low microcurie (μCi) activity. The photochemical processes generate most of the Radiography Laboratory's routinely generated hazardous waste, and most of that is generated by the DuPont film processor. Because the DuPont film processor generates the most photochemical waste, it was selected for an estimated material balance

  6. Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and detector characteristics.

    Science.gov (United States)

    Jain, Amit; Kuhls-Gilcrist, Andrew T; Gupta, Sandesh K; Bednarek, Daniel R; Rudin, Stephen

    2010-03-01

    The MTF, NNPS, and DQE are standard linear system metrics used to characterize intrinsic detector performance. To evaluate total system performance for actual clinical conditions, generalized linear system metrics (GMTF, GNNPS and GDQE) that include the effect of the focal spot distribution, scattered radiation, and geometric unsharpness are more meaningful and appropriate. In this study, a two-dimensional (2D) generalized linear system analysis was carried out for a standard flat panel detector (FPD) (194-micron pixel pitch and 600-micron thick CsI) and a newly-developed, high-resolution, micro-angiographic fluoroscope (MAF) (35-micron pixel pitch and 300-micron thick CsI). Realistic clinical parameters and x-ray spectra were used. The 2D detector MTFs were calculated using the new Noise Response method and slanted edge method and 2D focal spot distribution measurements were done using a pin-hole assembly. The scatter fraction, generated for a uniform head equivalent phantom, was measured and the scatter MTF was simulated with a theoretical model. Different magnifications and scatter fractions were used to estimate the 2D GMTF, GNNPS and GDQE for both detectors. Results show spatial non-isotropy for the 2D generalized metrics which provide a quantitative description of the performance of the complete imaging system for both detectors. This generalized analysis demonstrated that the MAF and FPD have similar capabilities at lower spatial frequencies, but that the MAF has superior performance over the FPD at higher frequencies even when considering focal spot blurring and scatter. This 2D generalized performance analysis is a valuable tool to evaluate total system capabilities and to enable optimized design for specific imaging tasks.

  7. Computed radiography in NDT application

    International Nuclear Information System (INIS)

    Deprins, Eric

    2004-01-01

    Computed Radiography, or digital radiography by use of reusable Storage Phosphor screens, offers a convenient and reliable way to replace film. In addition to the reduced cost on consumables, the return on investment of CR systems is strongly determined by savings in exposure time, processing times and archival times. But also intangible costs like plant shutdown, environment safety and longer usability of isotopes are increasingly important when considering replacing film by Storage Phosphor systems. But mote than in traditional radiography, the use of digital images is a trade-off between the speed and the required quality. Better image quality is obtained by longer exposure times, slower phosphor screens and higher scan resolutions. Therefore, different kinds of storage phosphor screens are needed in order to cover every application. Most operations have the data, associated with the tests to be performed, centrally stored in a database. Using a digital radiography system gives not only the advantages of the manipulation of digital images, but also the digital data that is associated with it. Smart methods to associate cassettes and Storage screens with exposed images enhance the workflow of the NDT processes, and avoid human error. Automated measurements tools increase the throughput in different kinds of operations. This paper gives an overview of the way certain operations have decided to replace film by Computed Radiography, and what the major benefits for them have been.

  8. Computed radiography for breast cancer

    International Nuclear Information System (INIS)

    Yamada, Tatsuya; Muramatsu, Yukio

    1990-01-01

    In order to evaluate the possibility of using computed radiographic mammography in mass surveys of the breast, we have retrospectively examined 71 breast cancer lesions in 71 patients using computed radiographic and conventional non-screen mammographies and have carried out comparative studies on tumor detection rate and calcification. A 95.8% detection rate was obtained for the tumor image (n 71) using computed radiography (CR) and one of 93.0% using non-screen techniques. Three lesions remained undetected by either study. A 100% detection rate was obtained for calcification associated with cancer (n 33) from each method. No significant differences in either detection rate or calcification were seen between the two images. On the other hand, the ability to recognize tumor images (n 66) was as follows; CR superior to non-screen radiography in 53 lesions (80.3%), equal in eight lesions (12.1%) and inferior in five lesions (7.6%). For the calcification images (n 18), CR was superior to non-screen radiography in all 18 lesions. Obviously, CR gives better results than non-screen radiography. Furthermore, an adequate image can be obtained using CR even although the X-ray dosage is only a twentieth of that required for non-screen radiography. It can therefore be applied not only to mass surveys for breast cancer but also to routine clinical diagnoses. (author)

  9. Spatially coded backscatter radiography

    International Nuclear Information System (INIS)

    Thangavelu, S.; Hussein, E.M.A.

    2007-01-01

    Conventional radiography requires access to two opposite sides of an object, which makes it unsuitable for the inspection of extended and/or thick structures (airframes, bridges, floors etc.). Backscatter imaging can overcome this problem, but the indications obtained are difficult to interpret. This paper applies the coded aperture technique to gamma-ray backscatter-radiography in order to enhance the detectability of flaws. This spatial coding method involves the positioning of a mask with closed and open holes to selectively permit or block the passage of radiation. The obtained coded-aperture indications are then mathematically decoded to detect the presence of anomalies. Indications obtained from Monte Carlo calculations were utilized in this work to simulate radiation scattering measurements. These simulated measurements were used to investigate the applicability of this technique to the detection of flaws by backscatter radiography

  10. Radiography of pressure ulcers

    International Nuclear Information System (INIS)

    Borgstroem, P.S.; Ekberg, O.; Lasson, A.

    1988-01-01

    In patients with longstanding and/or deep pressure ulcers radiology is usually consulted. Survey radiography and sinography in 14 patients with pressure ulcers (6 over the tuber ischii and 8 over the femoral trochanter) were evaluated. Osteomyelitic involvement of adjacent bone was revealed in 9 patients on survey radiography. However, it was usually impossible to assess whether or not bony involvement represents healed or active osteomyelitis. Sinography did not contribute to the assessment of whether or not adjacent cortical bone was involved. However, when a fistulation to an adjacent joint was revealed this contributed substantially to the preoperative planning of resection. We therefore recommend that survey radiography and sinography should be included in the evaluation of these patients but that the results from such examinations are critically evaluated. Joint involvement should be taken seriously as progression of septic arthritis usually occurs rapidly. (orig.)

  11. New development of neutron radiography with a small cyclotron

    International Nuclear Information System (INIS)

    Ikeda, Yasushi; Ohkubo, Kohei; Kato, Toshihiko; Nakamura, Tomihisa; Fuji, Takayoshi.

    1990-01-01

    A series of neutron radiography testing has been performed for several years by using a small accelerator called 'Baby Cyclotron' manufactured by Japan Steel Works, Ltd. The Baby Cyclotron produces fast neutrons at the rate of 4x10 12 n/cm 2 s, and enables to perform neutron radiography imaging by various techniques. The most important application of this Baby Cyclotron radiography system is the non-destructive testing (NDT) of various explosive devices prepared for space launch vehicles. It is assured that thermal neutron radiography testing is a very useful means for the NDT. Also fast neutron radiography testing is in progress. The fast neutron radiography with a CR39 track-etch image recorder was developed, and it was shown to be the very useful NDT means when the thicker objects used for new H-2 launch vehicles had to be examined. Because thermal neutron radiography has the high detectability of hydrogenous materials, organic elastomers such as O-rings and explosive powder are clearly observable through the opaque steel walls of containers. The Baby Cyclotron and the neutron radiography facility, thermal neutron and fast neutron radiography testings and so on are reported. (K.I.)

  12. Dual-energy radiography of bone tissues using ZnSe-based scintielectronic detectors

    International Nuclear Information System (INIS)

    Grinyov, B.; Ryzhikov, V.; Lecoq, P.; Naydenov, S.; Opolonin, A.; Lisetskaya, E.; Galkin, S.; Shumeiko, N.

    2007-01-01

    Detectors of the scintillator-photodiode type were obtained on the basis of CsI(Tl), CdWO 4 and ZnSe(Te) crystals, and their comparative study was carried out, aiming at their use in X-ray computer tomography (CT). Because of their low afterglow level (10 ppm after 10 ms), CWO and ZnSe crystals are preferable for this application. A drawback of CWO is its lower (by 3 times) light output as compared with CsI(Tl). ZnSe has low transparence to intrinsic radiation; however, up to energies of 60-70 keV it is superior, as for the whole complex of its parameter, to materials traditionally used for CT detectors. The use of a dual-energy receiving-detecting circuit with a detector pair ZnSe/CsI or ZnSe/CdWO allows efficient distinction between muscular and bone tissues, which supports our earlier theoretical assumptions that this method could be successfully used for separate detection of materials differing in their effective atomic number Z eff and local density (e.g., calcium contents in bone densitometry)

  13. Examination of welds by digital radiography

    International Nuclear Information System (INIS)

    Ekinci, S.

    2004-01-01

    Industrial radiography is the oldest and most reliable non-destructive test method in the examination and two dimensional evaluation of weld defects. Digital radiographic methods provide more sensitive, faster and more reliable evaluation of defect images. One of the most important factors influencing the contrast and consequently the image quality is the noise on the film caused by scattered radiation. The digital image processing technique can eliminate the noise and improve the image quality. Digital radiography also enables three dimensional evaluation of weld defects. This work describes the use of digital radiography in the evaluation of defects in welds of different configurations by using a laser film digitizing system and an appropriate software programme. Advantages and limitations of the digital technique and conventional film radiography were discussed. (author)

  14. Examination of welds by digital radiography

    International Nuclear Information System (INIS)

    Ekinci, S.

    2004-01-01

    Full text: Industrial radiography is the oldest and most reliable non-destructive test method in the examination and two dimensional evaluation of weld defects. Digital radiographic methods provide more sensitive, faster and more reliable evaluation of defect images. One of the most important factors influencing the contrast and consequently the image quality is the noise on the film caused by scattered radiation. The digital image processing technique can eliminate the noise and improve the image quality. Digital radiography also enables three dimensional evaluation of weld defects. This work describes the use of digital radiography in the evaluation of defects in welds of different configurations by using a laser film digitizing system and an appropriate software programme. Advantages and limitations of the digital technique and conventional film radiography were discussed

  15. Development of tungsten collimators for industrial radiography

    International Nuclear Information System (INIS)

    Varkey, P.A.; Verma, P.B.; Jayakumar, T.K.; Mammachan, M.K.

    2001-01-01

    Collimators are essential components of industrial radiography set up as it provides radiation safety to persons involved in the radiography work. A collimator with optimum design features also helps in reducing the scattered radiation which in turn results in radiographs having better sensitivity. This papers describes the salient design features of the tungsten collimators developed by the BRIT, for industrial radiography. (author)

  16. Radiography and tomography using fission neutrons at FRM-II

    International Nuclear Information System (INIS)

    Buecherl, T.; Lierse von Gostomski, Ch.

    2004-01-01

    Fission neutrons offer complementary information in radiography and tomography compared to the well established techniques using X-rays, gamma-rays, thermal or cold neutrons. They penetrate thick layers of high density materials with only little attenuation, while for light, specially for hydrogen containing materials, their attenuation is high. In the past, fast neutrons for NDT (non-destructive testing) were only available at accelerator driven systems. These high energy neutrons have to be moderated to achieve acceptable detection efficiencies thus drastically reducing the available neutron intensities and either resulting in a high beam divergence or in additional losses in neutron intensities due to beam collimation. The recently installed neutron computerized tomography and radiography system NECTAR at the Forschungsreaktor Muenchen-II (FRM-II) overcomes these disadvantages by using fission neutrons of about 1.7 MeV mean energy created in two converter plates set-up of highly enriched uranium. The beam quality, i.e. the neutron divergence can be adapted to the object to be measured by using different collimators, resulting in L/D-values up to 300. The available neutron beam intensity at the measuring position is up to 1.7E+08 cm -2 s -1 for a maximum beam area of 40 cm x 40 cm. For conventional imaging a two-dimensional detector system based on a CCD-camera is used, other more specialised systems are available. (author)

  17. Radiography and tomography using fission neutrons at FRM-II

    Energy Technology Data Exchange (ETDEWEB)

    Buecherl, T.; Lierse von Gostomski, Ch. [Inst. fuer Radiochemie, TU-Muenchen, Garching (Germany)

    2004-07-01

    Fission neutrons offer complementary information in radiography and tomography compared to the well established techniques using X-rays, gamma-rays, thermal or cold neutrons. They penetrate thick layers of high density materials with only little attenuation, while for light, specially for hydrogen containing materials, their attenuation is high. In the past, fast neutrons for NDT (non-destructive testing) were only available at accelerator driven systems. These high energy neutrons have to be moderated to achieve acceptable detection efficiencies thus drastically reducing the available neutron intensities and either resulting in a high beam divergence or in additional losses in neutron intensities due to beam collimation. The recently installed neutron computerized tomography and radiography system NECTAR at the Forschungsreaktor Muenchen-II (FRM-II) overcomes these disadvantages by using fission neutrons of about 1.7 MeV mean energy created in two converter plates set-up of highly enriched uranium. The beam quality, i.e. the neutron divergence can be adapted to the object to be measured by using different collimators, resulting in L/D-values up to 300. The available neutron beam intensity at the measuring position is up to 1.7E+08 cm{sup -2} s{sup -1} for a maximum beam area of 40 cm x 40 cm. For conventional imaging a two-dimensional detector system based on a CCD-camera is used, other more specialised systems are available. (author)

  18. Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Nikolaou, Konstantin; Becker, Christoph R.; Reiser, Maximilian F. [Ludwig-Maximilians-University, Department of Clinical Radiology, Munich (Germany); Flohr, Thomas; Stierstorfer, Karl [CT Division, Siemens Medical Solutions, Forchheim (Germany)

    2005-02-01

    The aim of this technical investigation was the detailed description of a prototype flat panel detector computed tomography system (FPCT) and its initial evaluation in an ex vivo setting. The prototype FPCT scanner consists of a conventional radiographic flat panel detector, mounted on a multi-slice CT scanner gantry. Explanted human ex vivo heart and foot specimens were examined. Images were reformatted with various reconstruction algorithms and were evaluated for high-resolution anatomic information. For comparison purposes, the ex vivo specimens were also scanned with a conventional 16-detector-row CT scanner (Sensation 16, Siemens Medical Solutions, Forchheim, Germany). With the FPCT prototype used, a 1,024 x 768 resolution matrix can be obtained, resulting in an isotropic voxel size of 0.25 x 0.25 x 0.25 mm at the iso-center. Due to the high spatial resolution, very small structures such as trabecular bone or third-degree, distal branches of coronary arteries could be visualized. This first evaluation showed that flat panel detector systems can be used in a cone-beam computed tomography scanner and that very high spatial resolutions can be achieved. However, there are limitations for in vivo use due to constraints in low contrast resolution and slow scan speed. (orig.)

  19. Analysis of boron utilization in sample preparation for microorganisms detection by neutron radiography technique

    International Nuclear Information System (INIS)

    Wacha, Reinaldo; Crispim, Verginia R.

    2000-01-01

    The neutron radiography technique applied to the microorganisms detection is the study of a new and faster alternative for diagnosis of infectious means. This work presents the parameters and the effects involved in the use of the boron as a conversion agent, that convert neutrons in a particles, capable ones of generating latent tracks in a solid state nuclear tracks detector, CR-39. The collected samples are doped with the boron by the incubation method, propitiating an interaction microorganisms/boron, that will guarantee the identification of the images of those microorganisms, through your morphology. (author)

  20. Chest radiography: new technological developments and their applications

    NARCIS (Netherlands)

    Schalekamp, S.; Ginneken, B. van; Karssemeijer, N.; Schaefer-Prokop, C.M.

    2014-01-01

    Digital chest radiography is still the most common radiological examination. With the upcoming three-dimensional (3D) acquisition techniques the value of radiography seems to diminish. But because radiography is inexpensive, readily available, and requires very little dose, it is still being used

  1. Lung nodule detection by microdose CT versus chest radiography (standard and dual-energy subtracted).

    Science.gov (United States)

    Ebner, Lukas; Bütikofer, Yanik; Ott, Daniel; Huber, Adrian; Landau, Julia; Roos, Justus E; Heverhagen, Johannes T; Christe, Andreas

    2015-04-01

    The purpose of this study was to investigate the feasibility of microdose CT using a comparable dose as for conventional chest radiographs in two planes including dual-energy subtraction for lung nodule assessment. We investigated 65 chest phantoms with 141 lung nodules, using an anthropomorphic chest phantom with artificial lung nodules. Microdose CT parameters were 80 kV and 6 mAs, with pitch of 2.2. Iterative reconstruction algorithms and an integrated circuit detector system (Stellar, Siemens Healthcare) were applied for maximum dose reduction. Maximum intensity projections (MIPs) were reconstructed. Chest radiographs were acquired in two projections with bone suppression. Four blinded radiologists interpreted the images in random order. A soft-tissue CT kernel (I30f) delivered better sensitivities in a pilot study than a hard kernel (I70f), with respective mean (SD) sensitivities of 91.1%±2.2% versus 85.6%±5.6% (p=0.041). Nodule size was measured accurately for all kernels. Mean clustered nodule sensitivity with chest radiography was 45.7%±8.1% (with bone suppression, 46.1%±8%; p=0.94); for microdose CT, nodule sensitivity was 83.6%±9% without MIP (with additional MIP, 92.5%±6%; pmicrodose CT for readers 1, 2, 3, and 4 were 84.3%, 90.7%, 68.6%, and 45.0%, respectively. Sensitivities with chest radiography for readers 1, 2, 3, and 4 were 42.9%, 58.6%, 36.4%, and 90.7%, respectively. In the per-phantom analysis, respective sensitivities of microdose CT versus chest radiography were 96.2% and 75% (pmicrodose CT, the applied dose was 0.1323 mSv. Microdose CT is better than the combination of chest radiography and dual-energy subtraction for the detection of solid nodules between 5 and 12 mm at a lower dose level of 0.13 mSv. Soft-tissue kernels allow better sensitivities. These preliminary results indicate that microdose CT has the potential to replace conventional chest radiography for lung nodule detection.

  2. Digital and analogue industrial radiography, application fields

    International Nuclear Information System (INIS)

    Willems, Peter; Millord, Erik Yardin

    2000-01-01

    Full text: Reusable phosphor screens for computer radiography (CR), amorphous selenium screens for direct radiography (DR), film digitalisation (FD) constitute imaging methods accepted by industry and are used for non-destructive radiographic testing (RT). Economic pressures are involving and affecting digital RT technology. Standards and codes for film radiography and radioscopy qualification do no longer cover the wide range of digital RT applications. It will be our task to optimise the performance of digital RT characterisation and to create appropriate examination methods to use all these new and existent technologies. In the meantime, an increasing automation and control of manual methods of analogue radiography can as well be expected. (author)

  3. Proceeding of 6th short conference on neutron radiography

    International Nuclear Information System (INIS)

    Katsurayama, Kohsuke; Hiraoka, Eiichi; Tsujimoto, Tadashi

    1984-01-01

    The 6th short conference on neutron radiography was held on August 30 and 31, 1983, at the Research Reactor Institute, Kyoto niversity, as a part of the joint research program of the Institute. During the period since the first meeting in November, 1970, steady development was made in both research and practical use of neutron radiography in Japan owing to the persistent effort of the persons concerned. In the conference, 70 persons participated, and 21 papers were presented. The problems treated were the apparatuses of neutron television, neutron radiography and neutron photography, the various application of neutron radiography, the standard of neutron radiography and others. The high value of neutron radiography and the increasing demand to use this technique were shown in this meeting. Considering the recent rapid development of new technology, it is expected that neutron radiography will find the wide varieties of application in the near future. The proceedings of the conference are published by collecting the gists of papers, hoping to enhance joint effort and the exchange of information to develop neutron radiography. (Kako, I.)

  4. Neutron radiography of fuel pins

    International Nuclear Information System (INIS)

    Jackson, C.N. Jr.; Powers, H.G.; Burgess, C.A.

    1975-01-01

    Neutron radiography performed with a reactor source has been shown to be a superior radiographic method for the examination of unirradiated mixed oxide fuel pins at the Hanford Engineering Development Laboratory. Approximately 1,700 fuel pins were contained in a sample that demonstrated the capability of the method for detecting laminations, structural flaws, fissile density variation, hydrogenous inclusions and voids in assembled fuel pins. The nature, extent, and importance of the detected conditions are substantiated by gamma autoradiography and by destructive analysis employing alpha autoradiography, electron microprobe and visual inspection. Also, a series of radiographs illustrate the response of neutron radiography as compared to low voltage and high voltage x-ray and gamma source Iridium 192 radiography. (U.S.)

  5. Application of An Avalanche Photodiode in Synchrotron-Based Ultra-fast X-Radiography

    International Nuclear Information System (INIS)

    Cheong, S.-K.; Liu Jinyuan; Wang Jin; Powell, Christopher F.

    2004-01-01

    A possibility of using avalanche photodiode has been investigated while operated in current or continuous wave mode to accommodate high-intensity synchrotron x-ray beams in an ultra-fast x-radiography. To achieve a time resolution of 1 μs or better in a time-resolved x-radiograhic experiment, the entire time-sequence of the APD response to the pulsed synchrotron x-ray beam is recorded with time resolution of 1-2 ns. We have characterized the APD detector in the continuous wave mode to reveal its linearity, signal to noise ratio, and the time response with various circuit configurations. We have demonstrated that signal-to-noise ratio better than 1000 can be achieved, which is limited only by Poisson statistics. These detectors, coupled with finely focused x-rays, have been used to study structure and dynamics of supersonic fuel sprays with 50 μm-spatial resolution and μs-temporal resolution in the region close to an injection nozzle

  6. Mass chest radiography in Greece

    International Nuclear Information System (INIS)

    Papavasiliou, C.

    1987-01-01

    In Greece mass chest radiography has been performed regularly on various population groups as a measure to control tuberculosis. Routine chest radiography is performed in most Greek hospitals on admission. In this report available data-admittedly inadequate-directly or indirectly addressing the problem of benefit versus the risk or cost associated with this examination is presented

  7. Practical radiography. 11. ed.

    International Nuclear Information System (INIS)

    Hoxter, E.A.

    1982-01-01

    After a brief explanation of the basics of electricity, the fundamentals of radiography are dealt with in more detail - the discovery of X-rays, their nature and properties, the production of the X-ray image and ways of improving the image. A chapter is devoted to the important subject of radiation protection. Explanations are given of the use of the Siemens exposure tables, which make it simpler to modify exposures from the values given in the tables. There is also a section on some of the standard radiographic positioning for patients. The most common medical terms used in radiography and fluoroscopy are listed and an Appendix gives details of the major items of Siemens X-ray equipment. There is a list of literature recommended for further study. Theoretical explanations have been kept to a minimum so that information that is important to radiography can be emphasized. (orig./MG)

  8. 3D Modeling of Electric Fields in the LUX Detector

    OpenAIRE

    LUX Collaboration; Akerib, D. S.; Alsum, S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Brás, P.; Byram, D.; Cahn, S. B.

    2017-01-01

    This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacting massive particle (WIMP) searches. After the first period completed, a time-varying non-uniform negative charge developed in the polytetrafluoroethylene (PTFE) panels that define the radial boundary of the detector's active volume. This caused electric field variations in the detector in time, depth and azimuth, g...

  9. Recent developments in detectors/phantoms for dosimetry, X-ray quality assurance and imaging

    International Nuclear Information System (INIS)

    Sankaran, A.

    2009-01-01

    During the past years, many new developments have taken place in detectors/phantoms for high energy photon and electron dosimetry (for radiotherapy), protection monitoring, X-ray quality assurance and X-ray imaging (for radiodiagnosis). A variety of detectors and systems, quality assurance (QA) gadgets and special phantoms have been developed for diverse applications. This paper discusses the important developments with some of which the author was actively associated in the past. For dosimetry and QA of 60 Co and high energy X-ray units, state-of-the-art radiation field analyzers, matrix ion chambers, MOSFET devices and Gafchromic films are described. OSL detectors find wide use in radiotherapy dosimetry and provide a good alternative for personnel monitoring. New systems introduced for QA/dosimetry of X-ray units and CT scanners include: multi-function instruments for simultaneous measurement of kVp, dose, time, X-ray waveform and HVT on diagnostic X-ray units; pencil chamber with head and body phantoms for CTDI check on CT scanners. Examples of phantoms used for dosimetry and imaging are given. Advancements in the field of diagnostic X-ray imaging (with applications in portal imaging/dosimetry of megavoltage X-ray units) have led to emergence of: film-replacement systems employing CCD-scintillator arrays, computed radiography (CR) using storage phosphor plate; digital radiography (DR), using a pixel-matrix of amorphous selenium, or amorphous silicon diode coupled to scintillator. All these provide (a) in radiotherapy, accurate dose delivery to tumour, saving the surrounding tissues and (b) in radiodiagnosis, superior image quality with low patient exposure. Lastly, iPODs and flash drives are utilized for storage of gigabyte-size images encountered in medical and allied fields. Although oriented towards medical applications, some of these have been of great utility in other fields, such as industrial radiography as well as a host of other research areas. (author)

  10. Standardization activities of the Euratom Neutron Radiography Working Group

    International Nuclear Information System (INIS)

    Domanus, J.

    1982-06-01

    In 1979 a working group on neutron radiography was formed at Euratom. The purpose of this group is the standardization of neutron radiographic methods in the field of nuclear fuel. Activities of this Neutron Radiography Working Group are revised. Classification of defects revealed by neutron radiography is illustrated in a special atlas. Beam purity and sensitivity indicators are tested together with a special calibration fuel pin. All the Euratom neutron radiography centers will perform comparative neutron radiography with those items. The measuring results obtained, using various measuring aparatus will form the basis to formulate conclusions about the best measuring methods and instruments to be used in that field. Besides the atlas of neutron radiographic findings in light water reactor fuel, the Euratom Neutron Radiogrphy Working Group has published a neutron radiography handbook in which the neutron radiography installations in the European Community are also described. (author)

  11. The Usefulness of Three-Dimensional Angiography with a Flat Panel Detector of Direct Conversion Type in a Transcatheter Arterial Chemoembolization Procedure for Hepatocellular Carcinoma: Initial Experience

    International Nuclear Information System (INIS)

    Kakeda, Shingo; Korogi, Yukunori; Hatakeyama, Yoshihisa; Ohnari, Norihiro; Oda, Nobuhiro; Nishino, Kazuyoshi; Miyamoto, Wataru

    2008-01-01

    The purpose of this study was to assess the usefulness of a three-dimensional (3D) angiography system using a flat panel detector of direct conversion type in treatments with subsegmental transcatheter arterial chemoembolization (TACE) for hepatocellular carcinomas (HCCs). Thirty-six consecutive patients who underwent hepatic angiography were prospectively examined. First, two radiologists evaluated the degree of visualization of the peripheral branches of the hepatic arteries on 3D digital subtraction angiography (DSA). Then the radiologists evaluated the visualization of tumor staining and feeding arteries in 25 patients (30 HCCs) who underwent subsegmental TACE. The two radiologists who performed the TACE assessed whether the additional information provided by 3D DSA was useful for treatments. In 34 (94.4%) of 36 patients, the subsegmental branches of the hepatic arteries were sufficiently visualized. The feeding arteries of HCCs were sufficiently visualized in 28 (93%) of 30 HCCs, whereas tumor stains were sufficiently visualized in 18 (60%). Maximum intensity projection images were significantly superior to volume recording images for visualization of the tumor staining and feeding arteries of HCCs. In 27 (90%) of 30 HCCs, 3D DSA provided additional useful information for subsegmental TACE. The high-quality 3D DSA with flat panel detector angiography system provided a precise vascular road map, which was useful for performing subsegmental TACE .of HCCs

  12. Comparison of clinical and physical measures of image quality in chest and pelvis computed radiography at different tube voltages

    International Nuclear Information System (INIS)

    Sandborg, Michael; Tingberg, Anders; Ullman, Gustaf; Dance, David R.; Alm Carlsson, Gudrun

    2006-01-01

    The aim of this work was to study the dependence of image quality in digital chest and pelvis radiography on tube voltage, and to explore correlations between clinical and physical measures of image quality. The effect on image quality of tube voltage in these two examinations was assessed using two methods. The first method relies on radiologists' observations of images of an anthropomorphic phantom, and the second method was based on computer modeling of the imaging system using an anthropomorphic voxel phantom. The tube voltage was varied within a broad range (50-150 kV), including those values typically used with screen-film radiography. The tube charge was altered so that the same effective dose was achieved for each projection. Two x-ray units were employed using a computed radiography (CR) image detector with standard tube filtration and antiscatter device. Clinical image quality was assessed by a group of radiologists using a visual grading analysis (VGA) technique based on the revised CEC image criteria. Physical image quality was derived from a Monte Carlo computer model in terms of the signal-to-noise ratio, SNR, of anatomical structures corresponding to the image criteria. Both the VGAS (visual grading analysis score) and SNR decrease with increasing tube voltage in both chest PA and pelvis AP examinations, indicating superior performance if lower tube voltages are employed. Hence, a positive correlation between clinical and physical measures of image quality was found. The pros and cons of using lower tube voltages with CR digital radiography than typically used in analog screen-film radiography are discussed, as well as the relevance of using VGAS and quantum-noise SNR as measures of image quality in pelvis and chest radiography

  13. Correlation of contrast-detail analysis and clinical image quality assessment in chest radiography with a human cadaver study.

    Science.gov (United States)

    De Crop, An; Bacher, Klaus; Van Hoof, Tom; Smeets, Peter V; Smet, Barbara S; Vergauwen, Merel; Kiendys, Urszula; Duyck, Philippe; Verstraete, Koenraad; D'Herde, Katharina; Thierens, Hubert

    2012-01-01

    To determine the correlation between the clinical and physical image quality of chest images by using cadavers embalmed with the Thiel technique and a contrast-detail phantom. The use of human cadavers fulfilled the requirements of the institutional ethics committee. Clinical image quality was assessed by using three human cadavers embalmed with the Thiel technique, which results in excellent preservation of the flexibility and plasticity of organs and tissues. As a result, lungs can be inflated during image acquisition to simulate the pulmonary anatomy seen on a chest radiograph. Both contrast-detail phantom images and chest images of the Thiel-embalmed bodies were acquired with an amorphous silicon flat-panel detector. Tube voltage (70, 81, 90, 100, 113, 125 kVp), copper filtration (0.1, 0.2, 0.3 mm Cu), and exposure settings (200, 280, 400, 560, 800 speed class) were altered to simulate different quality levels. Four experienced radiologists assessed the image quality by using a visual grading analysis (VGA) technique based on European Quality Criteria for Chest Radiology. The phantom images were scored manually and automatically with use of dedicated software, both resulting in an inverse image quality figure (IQF). Spearman rank correlations between inverse IQFs and VGA scores were calculated. A statistically significant correlation (r = 0.80, P chest radiography. © RSNA, 2011.

  14. Contemporary practice education: Exploring student perceptions of an industrial radiography placement for final year diagnostic radiography students

    International Nuclear Information System (INIS)

    Wareing, A.K.; Henderson, I.

    2015-01-01

    Introduction: There is a paucity of evidence in diagnostic radiography evaluating a career path into industrial imaging despite several higher education institutes stating this route as a career option on graduation. The link between a career in industrial radiography and diagnostic routes is unknown although there are anecdotal examples of individuals transferring between the two. Successfully obtaining a first post job following graduation in diagnostic radiography can be challenging in the current financial climate. A partnership was formed with an energy sector company that offered non-destructive testing/non-destructive evaluation (NDT/NDE) employing industrial radiographic technicians. Method: As an initial pilot, 5 (n = 5) final year diagnostic radiography students visited an industrial radiography site and underwent theoretical and practical training. Following this placement they engaged in a focus group and the student perceptions/responses were explored and recorded. Results: Common themes were identified and categorised via a thematic analysis. These were; radiation safety, physics and technology, widening access, graduate attributes/transferable skill sets and working conditions. Conclusion: Student discussion focussed around the benefits of working conditions in healthcare, the value of technology, safety and physics education in alternative placements and the transferability of skills into other/industrial sectors (e.g. NDT/NDE). Contemporary practice placements are a useful pedagogical approach to develop complex conceptual theoretical constructs, such as radiation physics. An in depth evaluation between the two industries skill sets is postulated. Additionally, this could offer alternative/emerging roles to interested diagnostic radiographers potentially meeting the skill shortage in industrial radiography. - Highlights: • Research in this area is novel. No evidence could be found to evaluate the links. • Students had theoretical

  15. Image quality of a Konica Regius 336 digital system in chest radiography

    International Nuclear Information System (INIS)

    Ostinelli, A.; Frigerio, M.; Monti, A.F.; Gelosa, S.; Tognoli, P.; Perniola, N.; Gozzi, G.

    2000-01-01

    Digital radiographic systems permit to optimize execution, depiction and storage of radiological images. Since a Regius 336 digital system (Konica Corp. Tokyo, Japan) devoted to chest radiography Department of S. Anna Hospital in Como, Italy, it was investigated its performance relative to image quality. Konica Regius 336 is a computed radiography system made of a phosphorescence detector plate which is scanned with an infrared semiconductor laser beam. The radiographic image obtained from the detector is subjected to image processing, which allows a stable output and the nonlinear curve typical of conventional radiographic systems. Image quality was assessed based on the following parameters: dose, contrast, noise and spatial resolution. As reference, it was assessed the same parameters on a Cronex 88 analogic chest-changer (DuPont Pharma, North Billerica, Mass, USA). The Regius 336 air kerma values were always higher than the analogic ones (about 10%), both with and without a chest phantom; noise was also greater than in analogic images, sometimes even doubled. The optical densities of a step wedge and the spatial resolution of the digital chest-changer are independent of the X-ray tube voltage consequent to broader optical latitude. Inversely, the analogic images of the wedges show great optical density variability as a function of the X-ray tube voltage (in a range of 2). The modulation transfer functions of the two systems have the same trend. The performance of the Konica Regius 336 is nearly equivalent to that of an analogic system. The main advantages of the digital system are a standard output, lower consumption of radiographic films, higher productiveness and better image quality standard level [it

  16. Preliminary performance of image quality for a low-dose C-arm CT system with a flat-panel detector

    Energy Technology Data Exchange (ETDEWEB)

    Kyung Cha, Bo [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Seo, Chang-Woo [Department of Radiation Convergence Engineering, College of Health Science, Yonsei University, Wonju (Korea, Republic of); Yang, Keedong [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Jeon, Seongchae, E-mail: sarim@keri.re.kr [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Huh, Young [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2015-06-01

    Digital flat panel imager (FPI)-based cone-beam computed tomography (CBCT) has been widely used in C-arm imaging for spine surgery and interventional procedures. The system provides real-time fluoroscopy with high spatial resolution and three-dimensional (3D) visualization of anatomical structure without the need for patient transportation in interventional suite. In this work, a prototype CBCT imaging platform with continuous single rotation about the gantry was developed by using a large-area flat-panel detector with amorphous Si-based thin film transistor matrix. The different 2D projection images were acquired during constant gantry velocity for reconstructed images at a tube voltage of 80–120 kVp, and different current (10–50 mA) conditions. Various scan protocols were applied to a chest phantom human by changing the number of projection images and scanning angles. The projections were then reconstructed into a volumetric data of sections by using a 3D reconstruction algorithm (e.g., filtered back projection). The preliminary quantitative X-ray performance of our CBCT system was investigated by using the American Association of Physicists in Medicine CT phantom in terms of spatial resolution, contrast resolution, and CT number linearity for mobile or fixed C-arm based CBCT application with limited rotational geometry. The novel results of the projection data with different scanning angles and angular increments in the orbital gantry platform were acquired and evaluated experimentally.

  17. Preliminary performance of image quality for a low-dose C-arm CT system with a flat-panel detector

    International Nuclear Information System (INIS)

    Kyung Cha, Bo; Seo, Chang-Woo; Yang, Keedong; Jeon, Seongchae; Huh, Young

    2015-01-01

    Digital flat panel imager (FPI)-based cone-beam computed tomography (CBCT) has been widely used in C-arm imaging for spine surgery and interventional procedures. The system provides real-time fluoroscopy with high spatial resolution and three-dimensional (3D) visualization of anatomical structure without the need for patient transportation in interventional suite. In this work, a prototype CBCT imaging platform with continuous single rotation about the gantry was developed by using a large-area flat-panel detector with amorphous Si-based thin film transistor matrix. The different 2D projection images were acquired during constant gantry velocity for reconstructed images at a tube voltage of 80–120 kVp, and different current (10–50 mA) conditions. Various scan protocols were applied to a chest phantom human by changing the number of projection images and scanning angles. The projections were then reconstructed into a volumetric data of sections by using a 3D reconstruction algorithm (e.g., filtered back projection). The preliminary quantitative X-ray performance of our CBCT system was investigated by using the American Association of Physicists in Medicine CT phantom in terms of spatial resolution, contrast resolution, and CT number linearity for mobile or fixed C-arm based CBCT application with limited rotational geometry. The novel results of the projection data with different scanning angles and angular increments in the orbital gantry platform were acquired and evaluated experimentally

  18. Use of informatics in radiation control panels

    International Nuclear Information System (INIS)

    Cochinal, R.; Grimont, B.; Mai, V.

    1980-03-01

    Radiation control panels with programmed systems have developed at the CEA over the last few years. Each monitored location is provided with an monitoring station containing: - a radiation detector and associated electronics (the output signal is normalised calibrated pulses), - an alarm unit to warn personnal of any danger inside the detection zone covered [fr

  19. A picture of radiography education across Europe

    International Nuclear Information System (INIS)

    McNulty, J.P.; Rainford, L.; Bezzina, P.; Henner, A.; Kukkes, T.; Pronk-Larive, D.; Vandulek, C.

    2016-01-01

    Purpose: To establish an understanding of radiography education across Europe by surveying higher education institutions registered as affiliate members of the European Federation of Radiography Societies (EFRS). Method: An online survey was developed to ascertain data on: curricula, duration, credit load, accreditation requirements, staff qualifications, staff and student exchange opportunities, and availability of postgraduate programmes. Responses were identifiable in terms of educational institution and country. All 46 affiliated educational institutions were invited to participate in the survey. Descriptive and thematic analyses are reported. Results: A response rate of 89.1% (n = 41) was achieved from educational institutions representing 21 countries. The majority of institutions (63.4%) offer a combined Medical Imaging, Radiotherapy and Nuclear Medicine programme; dedicated Medical Imaging programmes are offered by 14 institutions (34.2%); dedicated Radiotherapy programme by one institution (2.4%), and a dedicated Nuclear Medicine programme by only three institutions (6.5%). The Bologna (Bachelor) cycle has been adopted by 90.2% of responding institutions. The majority of institutions (53.7%) indicated programmes of 3 years in duration, others stated 3.5–4 years. Only 14.6% of institutions require ‘International Level’ accreditation for the Bachelors radiography programme. Postgraduate programmes were not offered by 26.8% of institutions and a deficit in Doctoral status for radiography educators was identified. Conclusions: The Bologna (Bachelor) cycle for radiography education has been adopted across the majority of institutions, however, full alignment remains a priority. Postgraduate radiography education opportunities across Europe appear to be insufficient and further investigation of radiography accreditation processes is justified to ensure harmonisation of practice. - Highlights: • The majority of institutions are compliant with the

  20. A new clinical unit for digital radiography based on a thick amorphous Selenium plate: Physical and psychophysical characterization

    International Nuclear Information System (INIS)

    Rivetti, Stefano; Lanconelli, Nico; Bertolini, Marco; Acchiappati, Domenico

    2011-01-01

    Purpose: Here, we present a physical and psychophysical characterization of a new clinical unit (named AcSelerate) for digital radiography based on a thick a-Se layer. We also compared images acquired with and without a software filter (named CRF) developed for reducing sharpness and noise of the images and making them similar to images coming from traditional computed radiography systems. Methods: The characterization was achieved in terms of physical figures of merit [modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE)], and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). We accomplished measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9. Results: The system shows an excellent MTF (about 50% at the Nyquist frequency). The DQE is about 55% at 0.5 lp/mm and above 20% at the Nyquist frequency and is almost independent from exposure. The contrast-detail curves are comparable to some of the best published data for other systems devoted to imaging in general radiography. The CRF filter influences both the MTF and NPS, but it does lead to very small changes on DQE. Also the visibility of CDRAD details is basically unaltered, when the filter is activated. Conclusions: As normally happens with detector based on direct conversion, the system presents an excellent MTF. The improved efficiency caused by the thick layer allows getting good noise characteristics and DQE results better (about 10% on average) than many of the computed radiography (CR) systems and comparable to those obtained by the best systems for digital radiography available on the market.

  1. Analysis of a 17C Panel Painting by Reflection Terahertz Time Domain-Imaging (THz-TDI): contribution of ultrafast optics to museum collections inspection

    DEFF Research Database (Denmark)

    Koch Dandolo, Corinna Ludovica; Filtenborg, Troels Folke; Uhd Jepsen, Peter

    2015-01-01

    THz-TDI has been applied for imaging an hidden painting and other subsurface composition layers of a 17C panel painting belonging to the National Gallery of Denmark. C- and B-scans realized by THz have been compared with images obtained by x-ray radiography, thus helping in a deep understanding...

  2. Information extraction from muon radiography data

    International Nuclear Information System (INIS)

    Borozdin, K.N.; Asaki, T.J.; Chartrand, R.; Hengartner, N.W.; Hogan, G.E.; Morris, C.L.; Priedhorsky, W.C.; Schirato, R.C.; Schultz, L.J.; Sottile, M.J.; Vixie, K.R.; Wohlberg, B.E.; Blanpied, G.

    2004-01-01

    Scattering muon radiography was proposed recently as a technique of detection and 3-d imaging for dense high-Z objects. High-energy cosmic ray muons are deflected in matter in the process of multiple Coulomb scattering. By measuring the deflection angles we are able to reconstruct the configuration of high-Z material in the object. We discuss the methods for information extraction from muon radiography data. Tomographic methods widely used in medical images have been applied to a specific muon radiography information source. Alternative simple technique based on the counting of high-scattered muons in the voxels seems to be efficient in many simulated scenes. SVM-based classifiers and clustering algorithms may allow detection of compact high-Z object without full image reconstruction. The efficiency of muon radiography can be increased using additional informational sources, such as momentum estimation, stopping power measurement, and detection of muonic atom emission.

  3. X-ray light valve (XLV): a novel detectors' technology for digital mammography

    Science.gov (United States)

    Marcovici, Sorin; Sukhovatkin, Vlad; Oakham, Peter

    2014-03-01

    A novel method, based on X-ray Light Valve (XLV) technology, is proposed for making good image quality yet inexpensive flat panel detectors for digital mammography. The digital mammography markets, particularly in the developing countries, demand quality machines at substantially lower prices than the ones available today. Continuous pressure is applied on x-ray detectors' manufacturers to reduce the flat panel detectors' prices. XLV presents a unique opportunity to achieve the needed price - performance characteristics for direct conversion, x-ray detectors. The XLV based detectors combine the proven, superior, spatial resolution of a-Se with the simplicity and low cost of liquid crystals and optical scanning. The x-ray quanta absorbed by a 200 μm a-Se produce electron - hole pairs that move under an electric field to the top and bottom of a-Se layer. This 2D charge distribution creates at the interface with the liquid crystals a continuous (analog) charge image corresponding to the impinging radiation's information. Under the influence of local electrical charges next to them, the liquid crystals twist proportionally to the charges and vary their light reflectivity. A scanning light source illuminates the liquid crystals while an associated, pixilated photo-detector, having a 42 μm pixel size, captures the light reflected by the liquid crystals and converts it in16 bit words that are transmitted to the machine for image processing and display. The paper will describe a novel XLV, 25 cm x 30 cm, flat panel detector structure and its underlying physics as well as its preliminary performance measured on several engineering prototypes. In particular, the paper will present the results of measuring XLV detectors' DQE, MTF, dynamic range, low contrast resolution and dynamic behavior. Finally, the paper will introduce the new, low cost, XLV detector based, digital mammography machine under development at XLV Diagnostics Inc.

  4. Radiographic inspection. Film replacement with digital detector arrays in aerospace applications

    International Nuclear Information System (INIS)

    Schulte, Frank; Bavendiek, Klaus

    2016-01-01

    The new Digital Radiographic Inspection method replace more and more the conventional Film technique. For DDA (Digital Detector Array) systems it is currently necessary to use automated or semi-automated systems. For CR (Computer Radiography) Systems the conventional Film Systems may be used. For this CR technique operators can use same X-Ray Units (Bunker) and same X-Ray equipment. But on CR technique we have basically the same settings like the Film-based technique. More or less same exposure times and for aerospace application long scanning times for the CR foils. In fact there is no big benefit in capacity or in economical view. Regarding this issue we thought about the option to use a DDA System instead of a Film or CR System to use the current Film Equipment (Bunker, Generator, Tube.) and replace this 1:1 by a manual system. In this time only small detectors with fine pixel pitch was available on the market. With this type of DDA's is was absolutely uneconomical to inspect parts in serial inspection. Therefore a new generation of DDA's were developed, which is able to replace Film or CR System 1:1 with adequate economical properties for specific applications. The new PerkinElmer XRD 1611 Panel has a size of 40 x 40 cm and a pixel pitch of 100 μm. The baseline for the new DDA Panel was the most used X-Ray Film in size 30 x 40 cm. The Pixel Pitch and requirements for Bad Pixel based on the requirements for spatial resolution of the applicable ASTM standards and different customer specifications for castings. With this new DDA System is it possible to inspect small and medium castings in very short time with excellent image quality. The System is able to process images under 1 minute include averaging. Images will be transferred by a specific software tool to an offline reading station where certified Level 2 operator can inspect the images. Images will be archived as 16bit DICONDE File. All relevant images information are included in DICONDE File

  5. Filmless radiography - present possibilities and direction of future developing

    International Nuclear Information System (INIS)

    Wocial, A.; Wojciechowski, Z.A.; Rozenblicki, Z.

    2008-01-01

    The paper presents introduction for new filmless radiography like CR Computed Radiography and DR Digital Radiography direct and non direct. The main factors are considered, which determine classification to different type of radiography. For each technique authors describe advantages and disadvantages supporting by practice examples. Paper contains a lot of practical information about a most of existing radiographic equipment at the NDT market. (author)

  6. SIMPLE for industrial radiography

    International Nuclear Information System (INIS)

    Azhar Azmi; Abd Nassir Ibrahim; Siti Madiha Muhammad Amir; Glam Hadzir Patai Mohamad; Saidi Rajab

    2004-01-01

    The first thing industrial radiographers have to do before commencing radiography works is to determine manually the amount of correct exposure that the film need to be exposed in order to obtain the right density. The amount of exposure depends on many variables such as type of radioisotope, type of film, nature of test-object and its orientation, and specific arrangement related to object location and configuration. In many cases radiography works are rejected because of radiographs fail to meet certain reference criteria as defined in the applicable standard. One of the main reasons of radiograph rejection is due to inadequate exposure received by the films. SIMPLE is a software specially developed to facilitate the calculation of gamma-radiography exposure. By using this software and knowing radiographic parameters to be encountered during the work, it is expected that human error will be minimized, thus enhancing the quality and productivity of NDT jobs. (Author)

  7. Apparatus for gamma radiography

    International Nuclear Information System (INIS)

    1983-06-01

    The aim of the present standard is to fix the rules for the construction of gamma radiography instrumentation without prejudice to the present regulations. These apparatus have to be fitted with only sealed sources conformable to the experimental standard M 61-002. The present standard agrees with the international standard ISO 3999 of 1977 dealing with the same subject. Nevertheless, it is different on the three main following points: it does not accept the same limits of absorbed dose rates in the air calculated on the external surface of projectors; it precribes tightness, bending, crushing and tensile tests for some components of the gamma radiography it prescribes tests of endurance and resistance to breaking for the locking systems of the gamma radiography apparatus. The present standard also specifies the following points: symbols and indications to put on projectors and on the source-holder; identification of the source contained in the projector; and, accompanying documents. The regulation references are given in annexe [fr

  8. Heavy-ion radiography applied to charged particle radiotherapy

    International Nuclear Information System (INIS)

    Chen, G.T.Y.; Fabrikant, J.I.; Holley, W.R.; Tobias, C.A.; Castro, J.R.

    1980-01-01

    The objectives of the heavy-ion radiography research program applied to the clinical cancer research program of charged particle radiotherapy have a twofold purpose: (1) to explore the manner in which heavy-ion radiography and CT reconstruction can provide improved tumor localization, treatment planning, and beam delivery for radiotherapy with accelerated heavy charged particles; and (2) to explore the usefulness of heavy-ion radiography in detecting, localizing, and sizing soft tissue cancers in the human body. The techniques and procedures developed for heavy-ion radiography should prove successful in support of charged particle radiotherapy

  9. Dosimetry and image quality assessment in a direct radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruno Beraldo; Paixao, Lucas; Nogueira, Maria do Socorro, E-mail: boliveira.mg@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Oliveira, Marcio Alves de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Fac. de Medicina. Dept. de Anatomia e Imagem; Teixeira, Maria Helena Araujo [Clinica Dra. Maria Helena Araujo Teixeira, Belo Horizonte, MG (Brazil)

    2014-11-15

    Objective: to evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and methods: Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results: considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion: the present study contributes to verify the equipment conformity as regards dose values and image quality. (author)

  10. Estimation of Absorbed Dose in Occlusal Radiography

    International Nuclear Information System (INIS)

    Yoo, Young Ah; Choi, Karp Shick; Lee, Sang Han

    1990-01-01

    The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-210 Head and Neck Section R, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70 Kvp and 15 mA, 1/4 second (8 inch cone ) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In Mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  11. Which technologies to replace gamma radiography?

    International Nuclear Information System (INIS)

    Zani-Demange, M.L.; Chauveau, D.

    2012-01-01

    Gamma radiography with iridium source is largely used in the industrial sector for the control of welds, tubes and pressure vessels as well as for monitoring corrosion. Hazards due to the handling of ionizing radiation sources (Ir 192 ) and constraints due to a more and more demanding regulations call for alternative methods. The French 'Institut de soudure' has led a 4-year long study (Alter-X project) and has identified 3 alternative methods for the iridium gamma radiography: -) the TOFD (Time Of Flight Diffraction) which is based on the analysis of the diffraction of ultrasound waves on the edges of defects; -) phased array ultrasound which is based on a series of elementary sensors that can be handled in an individual manner by specific electronics, the sweeping is no more manual but electronic and enables the operator to localize and size defects deep under the surface; -) digit radiography that is a common radiography in which the film is replaced by a re-usable phosphorus screen that is more sensitive and can be easily digitalized and has no need for a chemical treatment to be read. Digit radiography used with Se 75 (another gamma emitter) gives comparable or even better results than with Ir 192 but with a dose rate cut by half at least. (A.C.)

  12. Industrial Radiography: Principle and Practical

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    The successful and effectiveness of radiography method as a tool to increase quality level and safety of the engineering system and processing plants depend with the level of radiographer knowledge as service provider and also as supervisor. This book was published as effort several local experts to give their knowledge, theory and practical related to radiography technique to the involved public directly or indirectly. This book started with basic physic knowledge that becomes a root to radiography technology. Then, followed by discussion on tools and device that used in radiography work including x-ray machine, gamma projector, film, dark room, and others. Each aspect of radiograph quality also mentioned here to guide the reader on how to produce good radiograph that filled the specification wanted. The good radiograph does not mean anything if it failed to be interpreted correctly. Because of that, this book also explain how to choose good radiograph that qualified to be interpreted and after that how interpretation and evaluation process of object quality inspected was implemented based on image digestion that showed in radiograph. Several code and standard that usually applied in this country also will be referred as well for this work.

  13. Imaging the density profile of a volcano interior with cosmic-ray muon radiography combined with classical gravimetry

    International Nuclear Information System (INIS)

    Okubo, S; Tanaka, H K M

    2012-01-01

    Cosmic-ray muon radiography has the potential to reveal the density structure of gigantic objects. It utilizes the strong penetration ability of high-energy muons. By measuring the number of muons that travel through a target object, the average density can be calculated along the muon path. Since muons travel in straight paths through matter, specially designed detectors can generate density maps with higher spatial resolution than those obtained with conventional geophysical methods. However, this technique has a few notable limitations in that it can only be applied to near-surface structures above the muon sensor and strongly depends on the characteristics of the local topography. This is due to the fact that almost all cosmic-ray muons arrive only from the upper hemisphere. Geological structures, e.g. volcanoes, that allow for muon detectors to be placed on a slope directly below the point of interest are thus the best candidates for this technique. The drawback of muon radiography that only the horizontally integrated density above the sensor is measured with a time resolution larger than several weeks may be partly remedied by combining its results with gravity data, as they are both sensitive to target density while complementary to each other in several aspects. An example of such a combination is presented: real-time monitoring of magma head height in a volcano conduit. (topical review)

  14. Radiation Safety in Industrial Radiography. Specific Safety Guide (Spanish Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography

  15. Radiation Safety in Industrial Radiography. Specific Safety Guide (French Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in … shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography

  16. Radiation Safety in Industrial Radiography. Specific Safety Guide (Arabic Edition)

    International Nuclear Information System (INIS)

    2012-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  17. Neutron radiography at the SCK/CEN

    International Nuclear Information System (INIS)

    Tourwe, H.

    1977-01-01

    Neutron radiography has become in recent years a very important method of nondestructive testing in industry and research. The earliest practical application of neutron radiography has probably been the inspection of highly radioactive material: originally irradiated reactor fuels. Applications then progressed to other nuclear and industrial inspection problems. Neutron radiography and the conventional X-ray or gamma techniques are complementary. Some of the most important application fields of neutron radiography are: the detection of light elements (H, Li, B,...) with a very high scattering of absorption cross section for thermal neutrons; the nondestructive control of fuel before and after irradiation; controls where a distinction has to be made between isotopes of the same element ( 235 U and 238 U, 10 B and 11 B,...) and between components of a similar atomic number (Fe and Zn); the control of materials with a high density; the study of corrosion in closed structures; the control of the homogeneity of foreign materials in alloys,.... (author)

  18. Radiological protection procedures for industrial applications of computed radiography

    International Nuclear Information System (INIS)

    Aquino, Josilto Oliveira de

    2009-03-01

    Due to its very particular characteristics, industrial radiography is responsible for roughly half of the relevant accidents in nuclear industry, in developed as well as in developing countries, according to the International Atomic Energy Agency (IAEA). Thus, safety and radiological protection in industrial gamma radiography have been receiving especial treatment by regulatory authorities of most Member States. The main objective of the present work was to evaluate, from the radioprotection point of view, the main advantages of computed radiography (CR) for filmless industrial radiography. In order to accomplish this, both techniques, i.e. conventional and filmless computed radiography were evaluated and compared through practical studies. After the studies performed at the present work it was concluded that computed radiography significantly reduces the inherent doses, reflecting in smaller restricted areas and costs, with consequent improvement in radiological protection and safety. (author)

  19. Dual-energy subtraction radiography of the breast

    International Nuclear Information System (INIS)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-01-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses. (author)

  20. Dual-energy subtraction radiography of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-06-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses.

  1. Neutron radiography for nondestructive testing

    International Nuclear Information System (INIS)

    John, J.

    1979-01-01

    Neutron radiography is similar to X-ray inspection in that both depend upon use of radiation that penetrates some materials and is absorbed by others to provide a contrast image of conditions not readily available for visual inspection. X-rays are absorbed by dense materials, such as metals, whereas neutrons readily penetrate metals, but are absorbed by materials containing hydrogen. The neutron radiography has been successfully applied to a number of inspection situations. These include the inspection of explosives, advanced composites, adhesively bonded structures and a number of aircraft engine components. With the availability of Californium-252, it has become feasible to construct mobile neutron radiography systems suitable for field use. Such systems have been used for in-situ inspection of flight line aircraft, particularly to locate and measure hidden corrosion

  2. Developments in digital radiography: an equipment update

    International Nuclear Information System (INIS)

    James, J.J.; O'Connor, P.J.; Davies, A.G.; Cowen, A.R.

    2001-01-01

    Digital X-ray imaging technology has advanced rapidly over the past few years. This review, particularly aimed at those involved in using and purchasing such technology, is an attempt to unravel some of the complexities of this potentially confusing subject. The main groups of X-ray imaging devices that are considered are digitisers of conventional radiographs, image-intensifier-based fluorography systems, photostimulable phosphor computed radiography, amorphous selenium-based technology for thorax imaging and flat-panel systems. As well as describing these different systems, we look at ways of objectively assessing their image quality. Concepts that are used and explained include spatial resolution, grey-scale bit resolution, signal-to-noise ratio and detective quantum efficiency. An understanding of these basic parameters is vital in making a scientific assessment of a system's performance. Image processing and techniques are also briefly discussed, particularly with reference to their potential effects on image quality. This review aims to provide a basic understanding of digital X-ray imaging technology and enables the reader to make an independent and educated assessment of the relative merits of each system. (orig.)

  3. New north beam tube for the neutron radiography reactor

    International Nuclear Information System (INIS)

    Pruett, D.P.; Richards, W.J.; Heidel, C.C.

    1982-01-01

    Neutron radiography of the fuel undergoing examination in the argon cell is performed in the NRAD Facility and is one of many examinations performed on the fuel. The reactor and examination procedure are described. The new radiography system, developed to expand the present radiography capabilities to radiograph both irradiated and unirradiated specimens and to provide for the development of new radiography techniques without interfering with the argon cell production schedule is presented

  4. Quantitative film radiography

    International Nuclear Information System (INIS)

    Devine, G.; Dobie, D.; Fugina, J.; Hernandez, J.; Logan, C.; Mohr, P.; Moss, R.; Schumacher, B.; Updike, E.; Weirup, D.

    1991-01-01

    We have developed a system of quantitative radiography in order to produce quantitative images displaying homogeneity of parts. The materials that we characterize are synthetic composites and may contain important subtle density variations not discernible by examining a raw film x-radiograph. In order to quantitatively interpret film radiographs, it is necessary to digitize, interpret, and display the images. Our integrated system of quantitative radiography displays accurate, high-resolution pseudo-color images in units of density. We characterize approximately 10,000 parts per year in hundreds of different configurations and compositions with this system. This report discusses: the method; film processor monitoring and control; verifying film and processor performance; and correction of scatter effects

  5. Development of a fast multi-line x-ray CT detector for NDT

    International Nuclear Information System (INIS)

    Hofmann, T.; Nachtrab, F.; Schlechter, T.; Mühlbauer, J.; Schröpfer, S.; Firsching, M.; Uhlmann, N.; Neubauer, H.; Ernst, J.; Schweiger, T.; Oberst, M.; Meyer, A.

    2015-01-01

    Typical X-ray detectors for non-destructive testing (NDT) are line detectors or area detectors, like e.g. flat panel detectors. Multi-line detectors are currently only available in medical Computed Tomography (CT) scanners. Compared to flat panel detectors, line and multi-line detectors can achieve much higher frame rates. This allows time-resolved 3D CT scans of an object under investigation. Also, an improved image quality can be achieved due to reduced scattered radiation from object and detector themselves. Another benefit of line and multi-line detectors is that very wide detectors can be assembled easily, while flat panel detectors are usually limited to an imaging field with a size of approx. 40 × 40 cm 2 at maximum. The big disadvantage of line detectors is the limited number of object slices that can be scanned simultaneously. This leads to long scan times for large objects. Volume scans with a multi-line detector are much faster, but with almost similar image quality. Due to the promising properties of multi-line detectors their application outside of medical CT would also be very interesting for NDT. However, medical CT multi-line detectors are optimized for the scanning of human bodies. Many non-medical applications require higher spatial resolutions and/or higher X-ray energies. For those non-medical applications we are developing a fast multi-line X-ray detector.In the scope of this work, we present the current state of the development of the novel detector, which includes several outstanding properties like an adjustable curved design for variable focus-detector-distances, conserving nearly uniform perpendicular irradiation over the entire detector width. Basis of the detector is a specifically designed, radiation hard CMOS imaging sensor with a pixel pitch of 200 μ m. Each pixel has an automatic in-pixel gain adjustment, which allows for both: a very high sensitivity and a wide dynamic range. The final detector is planned to have 256 lines of

  6. The method of neutron imaging as a tool for the study of the dynamics of water movement in wet aramid-based ballistic body armour panels

    Science.gov (United States)

    Reifler, Felix A.; Lehmann, Eberhard H.; Frei, Gabriel; May, Hans; Rossi, René

    2006-07-01

    A new non-destructive method based on neutron imaging (neutron radiography) to determine the exact water content in aramid-based soft body armour panels is presented. While investigating the ballistic resistance of aramid-based body armour panels under a wet condition, it is important to precisely determine their water content and its chronological development. Using the presented method, the influence of water amount and location on impact testing as well as its time dependence was shown. In the ballistic panels used, spreading of water strongly depended on the kind of quilting. Very fast water migration could be observed when the panels were held vertically. Some first results regarding the water distribution in wet panels immediately after the impact are presented. On the basis of the presented results, requirements for a standard for testing the performance of ballistic panels in the wet state are deduced.

  7. An examination of automatic exposure control regimes for two digital radiography systems

    International Nuclear Information System (INIS)

    Marshall, N W

    2009-01-01

    The influence of two methods of an automatic exposure control (AEC) setup using a simple measure of detectability is examined as a function of x-ray beam quality for a computed radiography (CR) system and for an indirect conversion digital radiography (DR) system. The regimes assessed were constant air kerma at the detector and the constant contrast noise ratio (CNR). A low scatter geometry was employed with x-ray spectra varying from 60 kV and 1 mm Cu to 125 kV and 2 mm Cu. The CNR was measured using a 2 mm thick Al square of dimension 1 cm by 1 cm. Detectability was quantified via a nominal contrast for a fixed beam quality of 70 kV and 1 mm added Cu filtration, taken from c-d curves measured using the Leeds TO20 test object, for the four x-ray spectra. In addition, objective image quality parameters including modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) were also measured for both systems at the four different x-ray spectra. It was found that the constant air kerma strategy did not maintain threshold nominal contrast (simple detectability) constant as the x-ray beam mean energy increased, for either the CR system or the DR system. For the CR detector, the threshold nominal contrast for a 1 mm disc increased by a factor of 4.4 from 3.50% to 15.4% as the tube potential was raised from 60 kV to 125 kV, while for the DR detector, the threshold nominal contrast increased by a factor of 3.4, from 2.27% to 7.67% as the tube potential increased from 60 kV to 120 kV. The constant CNR method was more successful at maintaining constant detectability for the c-d discs. The threshold nominal contrast for the 1 mm disc changed by a factor of 1.2, from 4.80% to 5.70% for the CR system, as the spectrum changed from 60 kV to 125 kV. For the indirect conversion detector, the threshold nominal contrast increased from 2.27% to 5.66% (a factor of 1.4 increase). The constant CNR strategy required an increase in air kerma by

  8. An examination of automatic exposure control regimes for two digital radiography systems

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, N W [Radiation Safety Section, Clinical Physics CAU, Dominion House, 60, Barts Close, St Bartholomew' s Hospital, EC1A 7BE, London (United Kingdom)], E-mail: nicholas.marshall@uz.kuleuven.ac.be

    2009-08-07

    The influence of two methods of an automatic exposure control (AEC) setup using a simple measure of detectability is examined as a function of x-ray beam quality for a computed radiography (CR) system and for an indirect conversion digital radiography (DR) system. The regimes assessed were constant air kerma at the detector and the constant contrast noise ratio (CNR). A low scatter geometry was employed with x-ray spectra varying from 60 kV and 1 mm Cu to 125 kV and 2 mm Cu. The CNR was measured using a 2 mm thick Al square of dimension 1 cm by 1 cm. Detectability was quantified via a nominal contrast for a fixed beam quality of 70 kV and 1 mm added Cu filtration, taken from c-d curves measured using the Leeds TO20 test object, for the four x-ray spectra. In addition, objective image quality parameters including modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) were also measured for both systems at the four different x-ray spectra. It was found that the constant air kerma strategy did not maintain threshold nominal contrast (simple detectability) constant as the x-ray beam mean energy increased, for either the CR system or the DR system. For the CR detector, the threshold nominal contrast for a 1 mm disc increased by a factor of 4.4 from 3.50% to 15.4% as the tube potential was raised from 60 kV to 125 kV, while for the DR detector, the threshold nominal contrast increased by a factor of 3.4, from 2.27% to 7.67% as the tube potential increased from 60 kV to 120 kV. The constant CNR method was more successful at maintaining constant detectability for the c-d discs. The threshold nominal contrast for the 1 mm disc changed by a factor of 1.2, from 4.80% to 5.70% for the CR system, as the spectrum changed from 60 kV to 125 kV. For the indirect conversion detector, the threshold nominal contrast increased from 2.27% to 5.66% (a factor of 1.4 increase). The constant CNR strategy required an increase in air kerma by

  9. Neutron radiography at the Risoe National Laboratory

    International Nuclear Information System (INIS)

    Domanus, J.C.; Gade-Nielsen, P.; Knudsen, P.; Olsen, J.

    1981-11-01

    In this report six papers are collected which will be presented at the First World Conference on Neutron Radiography in San Diego, U.S.A., 7 - 10 December 1981. They are preceded by a short description of the activities of Risoe National Laboratory in the field of post-irradiation examination of nuclear fuel. One of the nondestructive methods used for this examination is neutron radiography. In the six conference papers different aspects of neutron radiography performed at Risoe are presented. (author)

  10. Application of (n, f)-radiography for assessment of environmental impact by uranium due to industrial activity

    International Nuclear Information System (INIS)

    Bertman, E.B.; Vasidov, A.; Tsipin, V.Z.; Tillaev, T.S.

    2001-01-01

    Neutron induced (n, f)-radiography has been used for assessment of radioactive impact on biota by industrial wastes and exhalation. The objects analyzed were tree leaves which can serve the natural seasonal microelements collectors. Sampling was made in the urban area with two main industrial plants - on the processing of atomic raw material and production of mineral fertilizer. The samples were analyzed by neutron activation analysis (NAA) and neutron induced (n, f)-radiography. The latter technique was used for the study of uranium distribution in a leaf surface. A procedure of the technique was that a detector foil (LEXAN) in a tied contact with a sample surface was subject to thermal neutron exposure in our WWR-SM nuclear reactor. Fission fragments from the 235U(n, f) reaction form radiation damages - tracks - in the surface layer of the detector. Due to close contact of the detector to the sample surface, location of tracks is consistent to location of the determined element. This makes it possible to get a picture of surface distribution of the element and, thus, to get an idea on genesis of pollution with this element. There are two principal ways for intake of pollutant elements in plants, namely, through the root system from the soil, and through the aerosol, dust and/or rain deposition on leaves. Presence of dense track spots like clusters or stars in the produced radiographs asserts their genesis was due to industrial disposal and exhalation. The average uranium concentrations in the leaves cover the range of 0.026 to 0.83 ppm. Based on the experimental data, uranium mapping of the explored territory has been made. Epicenter of the highest uranium level field was spatially consistent to location of the industrial plants, and, therefore, most probably, was generated by their activity

  11. Direct magnification radiography of the hand

    International Nuclear Information System (INIS)

    Presacco, D.; Pellegrini, A.; Di Maggio, C.

    1987-01-01

    The value of direct magnification radiography of the hand and the wrist has been studied in 128 patients affected by rheumatic diseases. Only in a small group (3.17%) magnification determined a higher percentage of correct diagnosis; in the 17.06% of cases direct magnification radiography provided useful increase in information but did not change the diagnisis correctly reached by conventional techniques. In most cases (79.76%) magnification provided only a better image quality but no more information helpful for the diagnosis, because of the high level achieved by convetional techniques. Therefore direct magnification radiography must be used only in selected cases and not as routine radiographyc technique

  12. Performance of low-cost X-ray area detectors with consumer digital cameras

    International Nuclear Information System (INIS)

    Panna, A.; Gomella, A.A.; Harmon, K.J.; Chen, P.; Miao, H.; Bennett, E.E.; Wen, H.

    2015-01-01

    We constructed X-ray detectors using consumer-grade digital cameras coupled to commercial X-ray phosphors. Several detector configurations were tested against the Varian PaxScan 3024M (Varian 3024M) digital flat panel detector. These include consumer cameras (Nikon D800, Nikon D700, and Nikon D3X) coupled to a green emission phosphor in a back-lit, normal incidence geometry, and in a front-lit, oblique incidence geometry. We used the photon transfer method to evaluate detector sensitivity and dark noise, and the edge test method to evaluate their spatial resolution. The essential specifications provided by our evaluation include discrete charge events captured per mm 2 per unit exposure surface dose, dark noise in equivalents of charge events per pixel, and spatial resolution in terms of the full width at half maximum (FWHM) of the detector's line spread function (LSF). Measurements were performed using a tungsten anode X-ray tube at 50 kVp. The results show that the home-built detectors provide better sensitivity and lower noise than the commercial flat panel detector, and some have better spatial resolution. The trade-off is substantially smaller imaging areas. Given their much lower costs, these home-built detectors are attractive options for prototype development of low-dose imaging applications

  13. Application of neutron radiography in Japan

    International Nuclear Information System (INIS)

    Kobayashi, M.; Wada, N.; Sekita, J.; Sanno-cho, Ota-ku, Tokyo, Japan)

    1983-01-01

    The history and the present state of neutron radiography in Japan are reviewed. Three types of neutron sources, namely nuclear reactors, accelerators and radioisotopes are now used. The interests on the application on neutron radiography become greater and greater in the industries, such as atomic energy, aeronautics and space etc. (Auth.)

  14. Need for New Optimisation Strategies in CR and Direct Digital Radiography

    International Nuclear Information System (INIS)

    Busch, H.P.

    2000-01-01

    Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, digital subtraction radiography and to fluoroscopy. Further work should lead to a definition of reference values for the dose and the image quality. This has to be done first for single exposures and fluoroscopic mode and secondly for diagnostic and interventional procedures. (author)

  15. Neutron radiography in Indian space programme

    International Nuclear Information System (INIS)

    Viswanathan, K.

    1999-01-01

    Pyrotechnic devices are indispensable in any space programme to perform such critical operations as ignition, stage separation, solar panel deployment, etc. The nature of design and configuration of different types of pyrotechnic devices, and the type of materials that are put in their construction make the inspection of them with thermal neutrons more favourable than any other non destructive testing methods. Although many types of neutron sources are available for use, generally the radiographic quality/exposure duration and cost of source run in opposite directions even after four decades of research and development. But in the area of space activity, by suitably combining the X-ray and neutron radiographic requirements, the inspection of the components can be made economically viable. This is demonstrated in the Indian space programme by establishing a 15 MeV linear accelerator based neutron generator facility to inspect medium to giant solid propellant boosters by X-ray inspection and all types of critical pyro and some electronic components by neutron radiography. Since the beam contains unacceptable gamma, transfer imaging technique has been evolved and the various parameters have been optimised to get a good quality image

  16. System of image package input and output for neutron radiography based on PC IBM XT/AT; Sistema paketnogo vvoda i vyvoda izobrazhenij dlya nejtronnoj radiografii na baze PEhVM IBM PC XCT/AT

    Energy Technology Data Exchange (ETDEWEB)

    Avarzad, O; Rikhvitskij, V S

    1996-12-31

    System of acquisition and analysis of both statistic and dynamic images of neutron radiography includes NM IBM PC XT/AT, super vidicon, telecamera based video detector, color monitor and interface board of image input-output. 2 refs.

  17. Design and theoretical investigation of a digital x-ray detector with large area and high spatial resolution

    Science.gov (United States)

    Gui, Jianbao; Guo, Jinchuan; Yang, Qinlao; Liu, Xin; Niu, Hanben

    2007-05-01

    X-ray phase contrast imaging is a promising new technology today, but the requirements of a digital detector with large area, high spatial resolution and high sensitivity bring forward a large challenge to researchers. This paper is related to the design and theoretical investigation of an x-ray direct conversion digital detector based on mercuric iodide photoconductive layer with the latent charge image readout by photoinduced discharge (PID). Mercuric iodide has been verified having a good imaging performance (high sensitivity, low dark current, low voltage operation and good lag characteristics) compared with the other competitive materials (α-Se,PbI II,CdTe,CdZnTe) and can be easily deposited on large substrates in the manner of polycrystalline. By use of line scanning laser beam and parallel multi-electrode readout make the system have high spatial resolution and fast readout speed suitable for instant general radiography and even rapid sequence radiography.

  18. Collaboration in radiography: A bibliometric analysis

    International Nuclear Information System (INIS)

    Snaith, Beverly

    2012-01-01

    Introduction: Increasing research activity is an aim of the radiography profession, but there is a lack of knowledge of how this can be achieved. Collaboration between clinical and academic centres as well as between individuals has increased productivity in other professions and has been suggested as a strategy for radiography. This bibliometric study maps the current contribution to the radiography evidence base through a single journal. Method: All articles published in Radiography from 1997 to 2011 were reviewed to identify collaboration trends together with article type and subject. Analysis also enabled comparison of research and publication patterns. Results: 706 articles were published by 1205 individual authors. 63.0% were written by UK based authors, although this varied over time. Over 80% of authors published only single article. Two thirds of articles were collaborative with an increase in clinical-academic co-authorship over the 15 years of the study. Although the majority of articles were diagnostic imaging based, the pattern mirrors the UK workforce profile. Clinicians, including clinical-academic co-authors, tend to write about clinical practice and roles, whereas academics write about a broader range of topics. Conclusions: There has been a growth in research and scholarship within the UK radiography journal and both clinical and academic radiographers are contributing to the evidence base through increased collaboration.

  19. Musculoskeletal imaging with a prototype photon-counting detector.

    Science.gov (United States)

    Gruber, M; Homolka, P; Chmeissani, M; Uffmann, M; Pretterklieber, M; Kainberger, F

    2012-01-01

    To test a digital imaging X-ray device based on the direct capture of X-ray photons with pixel detectors, which are coupled with photon-counting readout electronics. The chip consists of a matrix of 256 × 256 pixels with a pixel pitch of 55 μm. A monolithic image of 11.2 cm × 7 cm was obtained by the consecutive displacement approach. Images of embalmed anatomical specimens of eight human hands were obtained at four different dose levels (skin dose 2.4, 6, 12, 25 μGy) with the new detector, as well as with a flat-panel detector. The overall rating scores for the evaluated anatomical regions ranged from 5.23 at the lowest dose level, 6.32 at approximately 6 μGy, 6.70 at 12 μGy, to 6.99 at the highest dose level with the photon-counting system. The corresponding rating scores for the flat-panel detector were 3.84, 5.39, 6.64, and 7.34. When images obtained at the same dose were compared, the new system outperformed the conventional DR system at the two lowest dose levels. At the higher dose levels, there were no significant differences between the two systems. The photon-counting detector has great potential to obtain musculoskeletal images of excellent quality at very low dose levels.

  20. Dynamic flat panel detector versus image intensifier in cardiac imaging: dose and image quality

    Science.gov (United States)

    Vano, E.; Geiger, B.; Schreiner, A.; Back, C.; Beissel, J.

    2005-12-01

    The practical aspects of the dosimetric and imaging performance of a digital x-ray system for cardiology procedures were evaluated. The system was configured with an image intensifier (II) and later upgraded to a dynamic flat panel detector (FD). Entrance surface air kerma (ESAK) to phantoms of 16, 20, 24 and 28 cm of polymethyl methacrylate (PMMA) and the image quality of a test object were measured. Images were evaluated directly on the monitor and with numerical methods (noise and signal-to-noise ratio). Information contained in the DICOM header for dosimetry audit purposes was also tested. ESAK values per frame (or kerma rate) for the most commonly used cine and fluoroscopy modes for different PMMA thicknesses and for field sizes of 17 and 23 cm for II, and 20 and 25 cm for FD, produced similar results in the evaluated system with both technologies, ranging between 19 and 589 µGy/frame (cine) and 5 and 95 mGy min-1 (fluoroscopy). Image quality for these dose settings was better for the FD version. The 'study dosimetric report' is comprehensive, and its numerical content is sufficiently accurate. There is potential in the future to set those systems with dynamic FD to lower doses than are possible in the current II versions, especially for digital cine runs, or to benefit from improved image quality.