  1. New method for cardiac resynchronization therapy: Transapical endocardial lead implantation for left ventricular free wall pacing

    NARCIS (Netherlands)

    I. Kassai (Imre); C. Foldesi (Csaba); A. Szekely (Andrea); T. Szili-Torok (Tamas)

    2008-01-01

    textabstractCoronary sinus lead placement for transvenous left ventricular (LV) pacing in cardiac resynchronization therapy (CRT) has a significant failure rate at implant and a significant dislocation rate during follow-up. For these patients, epicardial pacing lead implantation is the most

  2. Could persistency of current of injury forecast successful active-fixation pacing lead implantation?

    Science.gov (United States)

    Shali, Shalaimaiti; Su, Yangang; Qin, Shengmei; Ge, Junbo

    2018-05-01

    Presence of adequate current of injury (COI) was recognized as a sign of favorable pacemaker lead outcome. Little is known regarding the value of its dynamic behavior. We sought to test whether persistency of COI could predict active-fixation pacing lead performance. COI was monitored up to 10min after right ventricular (RV) pacing electrode fixation. COI persistency was defined as the percentage of COI magnitude relative to its initial measurement. An unacceptable pacing threshold (≥1.0V in acute evaluation or ≥2.0V over 2-year follow-up) with or without lead dislodgement was considered as lead failure. Lead implantation was attempted for 217 times in 174 patients (age 66.3±7.8years, 78 female). Acute lead failures occurred 43 times. Independent predictors of acute lead failure were RV enlargement (odds ratio [OR] 1.23, 95% confidential interval [CI] 1.11-2.04, P=0.033), absence of COI (OR 3.13, 95%CI 2.08-9.09, P=0.027), and COI persistency at 5min (OR 0.32, 95%CI 0.20-0.69, P=0.001) and 10min (OR 0.41, 95%CI 0.13-0.77, P=0.001). The optimal cutoffs were COI 5min persistency ≥50% (sensitivity 81.4%; specificity 81.9%) and COI 10min persistency ≥20% (sensitivity 86%; specificity 88.6%). There were 12 lead failures during 24.0±6.4months of follow-up. Patients with COI 5min persistency ≥50% had higher event-free survival compared to those with COI 5min persistency <50% (hazard ratio 3.54, 95% CI 1.04-12.06, P=0.043). COI persistency appears to be a valuable indicator for both acute and long-term outcome of active-fixation pacemaker leads. A precipitous decline in COI may require more attention to make sure of the lead performance. Copyright © 2018 Elsevier Ireland Ltd. All rights reserved.

  3. The Use of a Quadripolar Left Ventricular Lead Increases Successful Implantation Rates in Patients with Phrenic Nerve Stimulation and/or High Pacing Thresholds Undergoing Cardiac Resynchronisation Therapy with Conventional Bipolar Leads

    Directory of Open Access Journals (Sweden)

    Marc-Alexander Ohlow, MD

    2013-03-01

    Conclusions: Excessively HPT and/or PNS are frequently encountered when conventional bipolar leads are used for CRT. A new quadripolar LV lead increases the rate of successful biventricular stimulation. Lower pacing threshold and freedom from PNS are maintained at follow-up.

  4. Acquired tricuspid valve stenosis associated with two ventricular endocardial pacing leads in a dog.

    Science.gov (United States)

    Tompkins, Emily; Dulake, Michelle I; Ghaffari, Shadie; Nakamura, Reid K

    2015-01-01

    Acquired tricuspid valve stenosis (TVS) is a rare complication of endocardial pacing lead implantation in humans that has only been described once previously in the veterinary literature in a dog with excessive lead redundancy. A 12 yr old terrier presented with right-sided congestive heart failure 6 mo after implantation of a second ventricular endocardial pacing lead. The second lead was placed due to malfunction of the first lead, which demonstrated abnormally low impedance. Transthoracic echocardiography identified hyperechoic tissue associated with the pacing leads as they crossed the tricuspid valve annulus as well as a stenotic tricuspid inflow pattern via spectral Doppler interrogation. Medical management was ultimately unsuccessful and the dog was euthanized 6 wk after TVS was diagnosed. The authors report the first canine case of acquired TVS associated with two ventricular endocardial pacing leads.

  5. Bipolar leads for use with permanently implantable cardiac pacing systems: a review of limitations of traditional and coaxial configurations and the development and testing of new conductor, insulation, and electrode designs.

    Science.gov (United States)

    Tyers, G F; Mills, P; Clark, J; Cheesman, M; Yeung-Lai-Wah, J A; Brownlee, R R

    1997-01-01

    The unacceptable rate of mechanical failures, threshold problems, and recalls experienced with many coaxial bipolar cardiac pacing lead designs are reviewed in detail. To address these problems, redundant insulation coradial atrial and ventricular tined leads (AL and VL, respectively) with iridium oxide electrodes were developed and subjected to extensive accelerated testing. There were no mechanical failures. The new lead body design proved to be much more durable than widely used trifilar MP35N configurations. The data reviewed and early and current test results are strongly supportive of tightly coupled insulation being a major factor in improving lead durability as long as the insulating material is not stressed. In addition to improving flex life, insulation adherence to the conductor may reduce the potential for ionic degradation. Pacing and sensing thresholds in animal studies of the new leads were within the reported range for leads with steroid eluting electrodes. A multicenter Canadian clinical trial was initiated with the first implant in early January 1994. By November 1995, 110 VL and 82 AL had been placed in 124 patients and followed for a mean of 11 +/- 6 months; maximum 21, total 1355. There were 60 males and 64 females with a mean age of 64 +/- 16 years, range 15-88. Primary indications for pacing were AV block in 61 patients, sick sinus syndrome in 53, vasovagal syncope in 4, and congestive heart failure in 7. Many patients had associated or primary tachyarrhythmias, including 111 with supraventricular and 12 with ventricular. Forty-two percent of patients (52/124) had prior cardiac procedures, including 18 open heart surgeries and 20 AV nodal ablations. At implant, 8 lead characteristics were rated good or excellent in 90% (746/829) of evaluations. X-ray visibility was of concern in 10% of patients (12/124). Three perioperative complications occurred, including displacement of one AL (1.2%) and one VL (0.9%). There were no subsequent mechanical

  6. Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads.

    Science.gov (United States)

    Candinas, R; Duru, F; Schneider, J; Lüscher, T F; Stokes, K

    1999-02-01

    To analyze the site and thickness of encapsulation around ventricular endocardial pacing leads and the extent of tricuspid valve adhesion, from today's perspective, with implications for lead removal and sensor location. Gross cardiac postmortem analysis was performed in 11 cases (8 female and 3 male patients; mean age, 78+/-7 years). None of the patients had died because of pacemaker malfunction. The mean implant time was 61+/-60 months (range, 4 to 184). The observations ranged from encapsulation only at the tip of the pacing lead to complete encapsulation along the entire length of the pacing lead within the right ventricle. Substantial areas of adhesion at the tricuspid valve apparatus were noted in 7 of the 11 cases (64%). The firmly attached leads could be removed only by dissection, and in some cases, removal was possible only by damaging the associated structures. No specific optimal site for sensor placement could be identified along the ventricular portion of the pacing leads; however, the fibrotic response was relatively less prominent in the atrial chamber. Extensive encapsulation is present in most long-term pacemaker leads, which may complicate lead removal. The site and thickness of encapsulation seem to be highly variable. Tricuspid valve adhesion, which is usually underestimated, may be severe. In contrast to earlier reports, our study demonstrates that the extent of fibrotic encapsulation may not be related to the duration since lead implantation. Moreover, we noted no ideal encapsulation-free site for sensors on the ventricular portion of long-term pacing leads.

  7. Minimal invasive epicardial lead implantation: optimizing cardiac resynchronization with a new mapping device for epicardial lead placement.

    Science.gov (United States)

    Maessen, J G; Phelps, B; Dekker, A L A J; Dijkman, B

    2004-05-01

    To optimize resynchronization in biventricular pacing with epicardial leads, mapping to determine the best pacing site, is a prerequisite. A port access surgical mapping technique was developed that allowed multiple pace site selection and reproducible lead evaluation and implantation. Pressure-volume loops analysis was used for real time guidance in targeting epicardial lead placement. Even the smallest changes in lead position revealed significantly different functional results. Optimizing the pacing site with this technique allowed functional improvement up to 40% versus random pace site selection.

  8. A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome

    DEFF Research Database (Denmark)

    Nielsen, Jens Cosedis; Thomsen, Poul Erik B; Højberg, Søren

    2011-01-01

    In patients with sick sinus syndrome, bradycardia can be treated with a single-lead pacemaker or a dual-chamber pacemaker. Previous trials have revealed that pacing modes preserving atrio-ventricular synchrony are superior to single-lead ventricular pacing, but it remains unclear if there is any ...

  9. Cardiac pacing systems and implantable cardiac defibrillators (ICDs): a radiological perspective of equipment, anatomy and complications

    Energy Technology Data Exchange (ETDEWEB)

    Burney, K. E-mail: apqz59@dsl.pipex.comk1511@hotmail.com; Burchard, F.; Papouchado, M.; Wilde, P

    2004-08-01

    Cardiac pacing is a proven and effective treatment in the management of many cardiac arrhythmias. Implantable cardiac defibrillators (ICDs) are beneficial for certain patient groups with a history of serious, recurrent ventricular dysrhythmias, with a high risk of sudden cardiac death. Pacemaker devices take many forms and are highly visible on the chest radiograph. The radiographic appearances of ICDs and pacemakers can be similar and are subject to similar complications. The anatomical approach to the implantation, the type of device used and anatomical variations will all affect the appearance of these devices on the chest film. Pacemaker complications identified radiographically include pneumothorax, lead malpositioning, lead displacement or fracture, fracture of outer conductor coil, loose connection between the lead and pacemaker connector block, lack of redundant loops in paediatric patients and excessive manipulation of the device by the patient (Twiddler's syndrome). This pictorial review highlights the role of chest radiography in the diagnosis of post-cardiac pacing and ICD insertion complications, as well as demonstrating the normal appearances of the most frequently implanted devices.

  10. Antitachycardia pacing programming in implantable cardioverter defibrillator: A systematic review.

    Science.gov (United States)

    De Maria, Elia; Giacopelli, Daniele; Borghi, Ambra; Modonesi, Letizia; Cappelli, Stefano

    2017-05-26

    Implantable cardioverter defibrillator (ICD) programming involves several parameters. In recent years antitachycardia pacing (ATP) has gained an increasing importance in the treatment of ventricular arrhythmias, whether slow or fast. It reduces the number of unnecessary and inappropriate shocks and improves both patient's quality of life and device longevity. There is no clear indication regarding the type of ATP to be used, except for the treatment of fast ventricular tachycardias (188 bpm-250 bpm) where it has been shown a greater efficacy and safety of burst compared to ramp; 8 impulses in each sequence of ATP appears to be the best programming option in this setting. Beyond ATP use, excellent clinical results were obtained with programming standardization following these principles: extended detection time in ventricular fibrillation (VF) zone; supraventricular discrimination criteria up to 200 bpm; first shock in VF zone at the maximum energy in order to reduce the risk of multiple shocks. The MADIT-RIT trial and some observational registries have also recently demonstrated that programming with a widespread use of ATP, higher cut-off rates or delayed intervention reduces the number of inappropriate and unnecessary therapies and improves the survival of patients during mid-term follow-up.

  11. Permanent pacing in infants and children: A single center experience in implantation and follow up

    Directory of Open Access Journals (Sweden)

    Rania Samir

    2011-09-01

    Conclusion: Permanent pacing in pediatric age group is relatively safe. However, there is substantial higher incidence of suboptimal pacing parameters and pacing system failures especially in younger and smaller children. Epicardial steroid eluting leads are comparable to endocardial steroid eluting leads in performance.

  12. Permanent pace maker implantation through axillary vein approach

    International Nuclear Information System (INIS)

    Shah, B.; Hussain, C.; Awan, Z.A.

    2017-01-01

    Device implantation is an integral part of interventional cardiology particularly electrophysiology. In this study, we are going to share our experience of device implantation technique at electrophysiology department Hayatabad Medical Complex, Peshawar. Methods: the study was conducted from June 2011 to December 2015. Axillary vein was used to implant the devices but in some cases when this rout was not convenient due to any reason then subclavian vein was entered through the Seldinger technique. Fluoroscopy time was less than 10 minutes and total procedure time was not more than 45 minutes. Electric cautery was used only in two cases. Pressure dressing was used in a few cases. Results: Total numbers of permanent pacemakers (PPM) remain 800 during the study period. There were 450 single chamber pacemakers and 350 dual chambers pacemakers. No case of any major bleeding was documented and in very few cases there was mild ooze from the procedure site after the operation which was tackled with pressure dressing. Four cases of pneumothorax were noted during the study period and in three cases chest intubation were done and one patient was kept on conservative management. Patient were followed after one month of discharge from the hospital and then yearly. Eight cases of lead dislodgment were documented during the study period. Conclusion: Axillary vein approach for implantation of permanent pacemakers is a safe and less time-consuming technique. (author)

  13. Epicardial left ventricular lead placement for cardiac resynchronization therapy: optimal pace site selection with pressure-volume loops.

    Science.gov (United States)

    Dekker, A L A J; Phelps, B; Dijkman, B; van der Nagel, T; van der Veen, F H; Geskes, G G; Maessen, J G

    2004-06-01

    Patients in heart failure with left bundle branch block benefit from cardiac resynchronization therapy. Usually the left ventricular pacing lead is placed by coronary sinus catheterization; however, this procedure is not always successful, and patients may be referred for surgical epicardial lead placement. The objective of this study was to develop a method to guide epicardial lead placement in cardiac resynchronization therapy. Eleven patients in heart failure who were eligible for cardiac resynchronization therapy were referred for surgery because of failed coronary sinus left ventricular lead implantation. Minithoracotomy or thoracoscopy was performed, and a temporary epicardial electrode was used for biventricular pacing at various sites on the left ventricle. Pressure-volume loops with the conductance catheter were used to select the best site for each individual patient. Relative to the baseline situation, biventricular pacing with an optimal left ventricular lead position significantly increased stroke volume (+39%, P =.01), maximal left ventricular pressure derivative (+20%, P =.02), ejection fraction (+30%, P =.007), and stroke work (+66%, P =.006) and reduced end-systolic volume (-6%, P =.04). In contrast, biventricular pacing at a suboptimal site did not significantly change left ventricular function and even worsened it in some cases. To optimize cardiac resynchronization therapy with epicardial leads, mapping to determine the best pace site is a prerequisite. Pressure-volume loops offer real-time guidance for targeting epicardial lead placement during minimal invasive surgery.

  14. [The pacemaker and implantable cardioverter-defibrillator registry of the Italian Association Arrhythmology Cardiac Pacing and cardiac pacing - annual report 2013].

    Science.gov (United States)

    Proclemer, Alessandro; Zecchin, Massimo; D'Onofrio, Antonio; Botto, Giovanni Luca; Rebellato, Luca; Ghidina, Marco; Bianco, Giulia; Bernardelli, Emanuela; Pucher, Elsa; Gregori, Dario

    2014-11-01

    The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2013 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers. The Registry collects prospectively national PM and ICD implantation activity on the basis of European cards. PM Registry: data about 25 419 PM implantations were collected (19 134 first implant and 6285 replacements). The number of collaborating centers was 275. Median age of treated patients was 80 years (74 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 43.6% of first PM implants, sick sinus syndrome in 24.7%, atrial fibrillation plus bradycardia in 12.9%, other in 18.8%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (23.2% of first implants). Use of single-chamber PMs was reported in 27.2% of first implants, of dual-chamber PMs in 62.6%, of PMs with cardiac resynchronization therapy (CRT) in 1.8%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 8.4%. ICD Registry: data about 16 519 ICD implantations were collected (11 474 first implants and 5045 replacements). The number of collaborating centers was 430. Median age of treated patients was 71 years (63 quartile I; 77 quartile III). Primary prevention indication was reported in 76% of first implants, secondary prevention in 24.0% (cardiac arrest in 7.8%). A single-chamber ICD was used in 27.2% of first implants, dual-chamber in 35.9% and biventricular in 36.8%. The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic

  15. Using left-ventricular-only pacing to eliminate T-wave oversensing in a biventricular implantable cardiac defibrillator.

    Science.gov (United States)

    Khoo, Clarence; Bennett, Matthew; Chakrabarti, Santabhanu; LeMaitre, John; Tung, Stanley K K

    2013-02-01

    A man aged 75 years and with nonischemic cardiomyopathy had implantation of a biventricular implantable cardiac defibrillator (ICD). Consistent biventricular pacing was limited by intermittent T-wave oversensing (TWOS). A strategy of left-ventricular-only pacing was used to eliminate TWOS. This strategy obviates the need to reduce ventricular sensitivity and thus may be an effective alternative to biventricular pacing complicated by TWOS. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  16. Clinical performance of different DF-4 implantable cardioverter defibrillator leads.

    Science.gov (United States)

    Sarrazin, Jean-François; Philippon, François; Sellier, Romain; André, Philippe; O'Hara, Gilles; Molin, Franck; Nault, Isabelle; Blier, Louis; Champagne, Jean

    2018-06-01

    Implantable cardioverter-defibrillator (ICD) DF-4 connectors have been introduced to facilitate defibrillator lead connection and to reduce the size of device header. There are limited data regarding the overall performance of those leads and no comparison between different ICD DF-4 leads. This is a cohort study of consecutive patients implanted with ICD DF-4 lead system at one University Centre between October 2010 and February 2015. A historical control group of patients with ICD DF-1 lead implantation was used for comparison. The following ICD DF-4 leads were evaluated: St. Jude Medical Durata 7122Q (St. Jude Medical, St. Paul, MN, USA), Medtronic Sprint Quattro Secure 6935 M (Medtronic Inc., Minneapolis, MN, USA), Boston Scientific Endotak Reliance 4-Site 0293 (Boston Scientific, Marlborough, MA, USA), and Boston Scientific Reliance 4-Front 0693. This study evaluated the acute and mid-term performances of those leads as well as complications. A total of 812 patients (age 63 ± 12 years, 80% male, left ventricular ejection fraction 31 ± 12%) underwent implantation of an ICD DF-4 lead. Acute and follow-up R-wave sensing and threshold were excellent. Compared to implantation, intrinsic R waves were higher at follow-up for Boston Scientific and Medtronic leads, and pacing lead impedances were lower for all leads at first follow-up (P < 0.001). The number of lead dislodgement or failure was similar between all leads. The estimated lead survival rates at 3 years were 95.6% for Boston Scientific Endotak 4-Site, 97.1% for Boston Scientific 4-Front, 97.7% for Medtronic Sprint Quattro, and 97.5% for St. Jude Durata (P  =  0.553). All ICD DF-4 leads had excellent acute and mid-term electrical performances. Longer follow-up will be necessary to confirm their sustained performance. © 2018 Wiley Periodicals, Inc.

  17. Merits and limitations of the mode switching rate stabilization pacing algorithms in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    The 7250 Jewel AF Medtronic model of ICD is the first implantable device in which both therapies for atrial arrhythmias and pacing algorithms for atrial arrhythmia prevention are available. Feasibility of that extensive atrial arrhythmia management requires correct and synergic functioning of different algorithms to control arrhythmias. The ability of the new pacing algorithms to stabilize the atrial rate following termination of treated atrial arrhythmias was evaluated in the marker channel registration of 600 spontaneously occurring episodes in 15 patients with the Jewel AF. All patients (55+/-15 years) had structural heart disease and documented atrial and ventricular arrhythmias. Dual chamber rate stabilization pacing was present in 245 (41 %) of episodes following arrhythmia termination and was a part of the mode switching operation during which pacing was provided in the dynamic DDI mode. This algorithm could function as the atrial rate stabilization pacing only when there was a slow spontaneous atrial rhythm or in presence of atrial premature beats conducted to the ventricles with a normal AV time. In case of atrial premature beats with delayed or absent conduction to the ventricles and in case of ventricular premature beats, the algorithm stabilized the ventricular rate. The rate stabilization pacing in DDI mode during sinus rhythm following atrial arrhythmia termination was often extended in time due to the device-based definition of arrhythmia termination. This was also the case in patients, in whom the DDD mode with true atrial rate stabilization algorithm was programmed. The rate stabilization algorithms in the Jewel AF applied after atrial arrhythmia termination provide pacing that is not based on the timing of atrial events. Only under certain circumstances the algorithm can function as atrial rate stabilization pacing. Adjustments in availability and functioning of the rate stabilization algorithms might be of benefit for the clinical performance of

  18. First implantation of selective his bundle pacing in Colombia. Report of two cases

    International Nuclear Information System (INIS)

    Velasquez, Jorge E; Duque, Mauricio; Marin V, Jorge E; Aristizabal, Julian M; Medina, Luis E; Gonzalez, Edgardo; Duque, Laura; Uribe, William

    2010-01-01

    Pacing in the right ventricular apex is known to produce ventricular dysynchrony and patients often develop dilated cardiomyopathy. For this reason, a more physiological stimulation has been performed. With the recent technological development of electrodes for selective stimulation of the His bundle, we want to show the experience of this type of implantation in the first two cases made in the electrophysiology laboratory in Medellin.

  19. Case study thoracic radiotherapy in an elderly patient with pacemaker: The issue of pacing leads

    Energy Technology Data Exchange (ETDEWEB)

    Kirova, Youlia M., E-mail: youlia.kirova@curie.net [Department of Radiation Oncology, Institut Curie, Paris (France); Menard, Jean; Chargari, Cyrus; Mazal, Alejandro [Department of Radiation Oncology, Institut Curie, Paris (France); Kirov, Krassen [Department of Anesthesiology and Reanimation, Institut Curie, Paris (France)

    2012-07-01

    To assess clinical outcome of patients with pacemaker treated with thoracic radiation therapy for T8-T9 paravertebral chloroma. A 92-year-old male patient with chloroma presenting as paravertebral painful and compressive (T8-T9) mass was referred for radiotherapy in the Department of Radiation Oncology, Institut Curie. The patient presented with cardiac dysfunction and a permanent pacemaker that had been implanted prior. The decision of Multidisciplinary Meeting was to deliver 30 Gy in 10 fractions for reducing the symptoms and controlling the tumor growth. The patient received a total dose of 30 Gy in 10 fractions using 4-field conformal radiotherapy with 20-MV photons. The dose to pacemaker was 0.1 Gy but a part of the pacing leads was in the irradiation fields. The patient was treated the first time in the presence of his radiation oncologist and an intensive care unit doctor. Moreover, the function of his pacemaker was monitored during the entire radiotherapy course. No change in pacemaker function was observed during any of the radiotherapy fractions. The radiotherapy was very well tolerated without any side effects. The function of the pacemaker was checked before and after the radiotherapy treatment by the cardiologist and no pacemaker dysfunction was observed. Although updated guidelines are needed with acceptable dose criteria for implantable cardiac devices, it is possible to treat patients with these devices and parts encroaching on the radiation field. This case report shows we were able to safely treat our patient through a multidisciplinary approach, monitoring the patient during each step of the treatment.

  20. Case study thoracic radiotherapy in an elderly patient with pacemaker: The issue of pacing leads

    International Nuclear Information System (INIS)

    Kirova, Youlia M.; Menard, Jean; Chargari, Cyrus; Mazal, Alejandro; Kirov, Krassen

    2012-01-01

    To assess clinical outcome of patients with pacemaker treated with thoracic radiation therapy for T8-T9 paravertebral chloroma. A 92-year-old male patient with chloroma presenting as paravertebral painful and compressive (T8-T9) mass was referred for radiotherapy in the Department of Radiation Oncology, Institut Curie. The patient presented with cardiac dysfunction and a permanent pacemaker that had been implanted prior. The decision of Multidisciplinary Meeting was to deliver 30 Gy in 10 fractions for reducing the symptoms and controlling the tumor growth. The patient received a total dose of 30 Gy in 10 fractions using 4-field conformal radiotherapy with 20-MV photons. The dose to pacemaker was 0.1 Gy but a part of the pacing leads was in the irradiation fields. The patient was treated the first time in the presence of his radiation oncologist and an intensive care unit doctor. Moreover, the function of his pacemaker was monitored during the entire radiotherapy course. No change in pacemaker function was observed during any of the radiotherapy fractions. The radiotherapy was very well tolerated without any side effects. The function of the pacemaker was checked before and after the radiotherapy treatment by the cardiologist and no pacemaker dysfunction was observed. Although updated guidelines are needed with acceptable dose criteria for implantable cardiac devices, it is possible to treat patients with these devices and parts encroaching on the radiation field. This case report shows we were able to safely treat our patient through a multidisciplinary approach, monitoring the patient during each step of the treatment.

  1. Direct His bundle pacing post AVN ablation.

    Science.gov (United States)

    Lakshmanadoss, Umashankar; Aggarwal, Ashim; Huang, David T; Daubert, James P; Shah, Abrar

    2009-08-01

    Atrioventricular nodal (AVN) ablation with concomitant pacemaker implantation is one of the strategies that reduce symptoms in patients with atrial fibrillation (AF). However, the long-term adverse effects of right ventricular (RV) apical pacing have led to the search for alternating sites of pacing. Biventricular pacing produces a significant improvement in functional capacity over RV pacing in patients undergoing AVN ablation. Another alternative site for pacing is direct His bundle to reduce the adverse outcome of RV pacing. Here, we present a case of direct His bundle pacing using steerable lead delivery system in a patient with symptomatic paroxysmal AF with concurrent AVN ablation.

  2. Interactions between pacing and arrhythmia detection algorithms in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    Dual chamber implantable cardioverter defibrillator (ICD) combines the possibility to detect and treat ventricular and atrial arrhythmias with the possibility of modern heart stimulation techniques. Advanced pacing algorithms together with extended arrhythmia detection capabilities can give rise to new types of device-device interactions. Some of the possible interactions are illustrated by four cases documented in four models of dual chamber ICDs. Functioning of new features in dual chamber devices is influenced by the fact that the pacemaker is not a separate device but a part of the ICD system and that both are being used in a patient with arrhythmia. Programming measures are suggested to optimize use of new pacing algorithms while maintaining correct arrhythmia detection.

  3. Increased base rate of atrial pacing for prevention of atrial fibrillation after implantation of a dual-chamber pacemaker: insights from the Atrial Overdrive Pacing Study.

    Science.gov (United States)

    Kantharia, Bharat K; Freedman, Roger A; Hoekenga, David; Tomassoni, Gery; Worley, Seth; Sorrentino, Robert; Steinhaus, David; Wolkowicz, Joel M; Syed, Zaffer A

    2007-11-01

    Different pacing sites and various algorithms have been utilized to prevent atrial fibrillation (AF) in pacemaker recipients. However, the optimal pacing rate settings have not yet been established. In this randomized, prospective, multicentre, single-blinded, cross over study, rate-adaptive pacing at a high base rate (BR) in patients, age 60 years or above, or a history of paroxysmal AF, who underwent dual-chamber (DDD) pacemaker implantation for standard pacing indications, was evaluated for prevention of AF. In the study cohort of 145 patients implanted with DDD pacemakers with a programmable rest rate (RR) feature, the BR/RR settings were sequentially but randomly adjusted as follows: 60 bpm/Off for the baseline quarter (initial 3 months) and then to either 'A-B-C' or 'C-B-A' settings (A = 70/65 bpm, B = 70/Off, C = 80/65 bpm) for the subsequent quarters each of 3 months duration. Data on automatic mode switch episodes, device diagnostics, and a questionnaire evaluating pacemaker awareness and palpitations were collected. Ninety-nine patients, mean age 77 +/- 10 years, who completed the study protocol and followed for 12 months did not show significant differences in the number of mode switch episodes between any settings used. The percentage of atrial pacing was lower during baseline pacing compared to settings A, B, and C (P < 0.0001). Setting C produced a higher percentage of atrial pacing than A and B (P < 0.01). Although a higher percentage of atrial pacing correlated with a lower incidence of mode switch episodes, there was no statistically significant difference in the number of mode switch episodes between settings A, B, and C. There were no significant differences in the questionnaire scores relating to pacemaker awareness or palpitation. Overdrive single-site pacing in the right atrium achieved by programming analysed settings in the present study did not reduce AF as assessed by mode switch episodes. Additionally, no change in the symptoms of

  4. Pacing Lead-Induced Granuloma in the Atrium: A Foreign Body Reaction to Polyurethane

    Directory of Open Access Journals (Sweden)

    Shinagawa Yoko

    2013-01-01

    Full Text Available We described a case of an 82-year-old male who presented with a granuloma entrapping the polyurethane-coated pacing lead at the site of contact on the atrium. He had been paced for 8 years without symptoms or signs suggestive of an allergic reaction to the pacemaker system and died from thrombosis of the superior mesenteric artery and heart failure. A histological examination of the nodule showed an incidental granuloma with multinucleated giant cells. No granuloma was found in the heart or the lung.

  5. Single lead atrial vs. dual chamber pacing in sick sinus syndrome

    DEFF Research Database (Denmark)

    Brandt, Niels H; Kirkfeldt, Rikke Esberg; Nielsen, Jens Cosedis

    2017-01-01

    Aims The DANPACE trial randomized patients with sick sinus syndrome (SSS) to single lead atrial (AAIR) or dual chamber (DDDR) pacemaker (PM). After 5 years follow-up, no difference in overall survival, stroke or heart failure (HF) was observed, whereas risk of atrial fibrillation (AF) and PM...... This register-based long-term follow-up study indicates that there is no difference in mortality among patients with SSS randomized to AAIR or DDDR pacing, even with very long follow-up. Nor is there any difference in risk of AF hospitalization, stroke or HF. The higher rate of pacing mode-change to DDDR...

  6. Effect of right ventricular pacing lead site on left ventricular function in patients with high-grade atrioventricular block: results of the Protect-Pace study.

    Science.gov (United States)

    Kaye, Gerald C; Linker, Nicholas J; Marwick, Thomas H; Pollock, Lucy; Graham, Laura; Pouliot, Erika; Poloniecki, Jan; Gammage, Michael

    2015-04-07

    Chronic right ventricle (RV) apical (RVA) pacing is standard treatment for an atrioventricular (AV) block but may be deleterious to left ventricle (LV) systolic function. Previous clinical studies of non-apical pacing have produced conflicting results. The aim of this randomized, prospective, international, multicentre trial was to compare change in LV ejection fraction (LVEF) between right ventricular apical and high septal (RVHS) pacing over a 2-year study period. We randomized 240 patients (age 74 ± 11 years, 67% male) with a high-grade AV block requiring >90% ventricular pacing and preserved baseline LVEF >50%, to receive pacing at the RVA (n = 120) or RVHS (n = 120). At 2 years, LVEF decreased in both the RVA (57 ± 9 to 55 ± 9%, P = 0.047) and the RVHS groups (56 ± 10 to 54 ± 10%, P = 0.0003). However, there was no significant difference in intra-patient change in LVEF between confirmed RVA (n = 85) and RVHS (n = 83) lead position (P = 0.43). There were no significant differences in heart failure hospitalization, mortality, the burden of atrial fibrillation, or plasma brain natriutetic peptide levels between the two groups. A significantly greater time was required to place the lead in the RVHS position (70 ± 25 vs. 56 ± 24 min, P function requiring a high percentage of ventricular pacing, RVHS pacing does not provide a protective effect on left ventricular function over RVA pacing in the first 2 years. ClinicalTrials.gov number NCT00461734. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  7. Acquired tricuspid valve stenosis due to intentionally redundant transvenous lead placement for VDD pacing in two small dogs.

    Science.gov (United States)

    Gunther-Harrington, Catherine T; Michel, Adam O; Stern, Joshua A

    2015-12-01

    Placement of an endocardial VDD pacing lead in small dogs (stenosis in two small dogs between 8 months and 4 years after VDD pacemaker placement for third-degree atrioventricular block. Echocardiography and Doppler echocardiography identified elevated transtricuspid flow velocities, prolonged pressure half-times, decreased valve leaflet excursions, and tricuspid regurgitation in both cases. Both cases were euthanized secondary to this pacing complication. Necropsy was performed in one case and confirmed adherence between the redundant lead loop, atrial and valve tissue. While VDD pacing in dogs has proven hemodynamic benefits, these benefits have not been demonstrated in terms of survival benefit or clinical signs. The requirement of redundant lead placement in small dogs for appropriate VDD lead function creates potential deleterious effects that should be weighed against the possible clinical value of VDD pacing in these patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: antitachycardia pacing therapy during charging.

    Science.gov (United States)

    Schoels, Wolfgang; Steinhaus, David; Johnson, W Ben; O'hara, Gilles; Schwab, Joerg O; Jenniskens, Inge; Degroot, Paul J; Tang, Feng; Helmling, Erhard

    2007-07-01

    Previous studies in implantable cardioverter-defibrillator (ICD) patients demonstrated the efficacy and safety of antitachycardia pacing (ATP) for rapid ventricular tachycardias (VT). To prevent shock delay in case of ATP failure, a new feature (ATP during charging) was developed to deliver ATP for rapid VT while charging for shock. The purpose of this study was to determine the efficacy and safety of this new feature. In a prospective, nonrandomized trial, patients with standard ICD indication received an EnTrust ICD. VT and ventricular fibrillation (VF) episodes were reviewed for appropriate detection, ATP success, rhythm acceleration, and related symptoms. In 421 implanted patients, 116 VF episodes occurred in 37 patients. Eighty-four (72%) episodes received ATP during or before charging. ATP prevented a shock in 58 (69%) of 84 episodes in 15 patients. ATP stopped significantly more monomorphic (77%) than polymorphic VTs (44%, P = .05). Five (6%) episodes accelerated after ATP but were terminated by the backup shock(s). No symptoms were related to ATP during charging. In four patients, 38 charges were saved by delivering ATP before charging. Of 98 induced VF episodes, 28% were successfully terminated by ATP versus 69% for spontaneous episodes (P <.01). Most VTs detected in the VF zone can be painlessly terminated by ATP delivered during charging, with a low risk of acceleration or symptoms. ATP before charging allows delivery of two ATP attempts before shock in the same time that would otherwise be required to deliver only one ATP plus a shock. It also offers potential battery energy savings.

  9. Additional electrodes on the Quartet™ LV lead provide more programmable pacing options than bipolar and tripolar equivalents.

    Science.gov (United States)

    O'Donnell, David; Sperzel, Johannes; Thibault, Bernard; Rinaldi, Christopher A; Pappone, Carlo; Gutleben, Klaus-Jürgen; Leclercq, Christopher; Razavi, Hedi; Ryu, Kyungmoo; Mcspadden, Luke C; Fischer, Avi; Tomassoni, Gery

    2017-04-01

    The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalents. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  10. Ischemic Stroke with Cardiac Pacemaker Implantation: Comparison of Physiological and Ventricular Pacing Modes.

    Science.gov (United States)

    Kato, Yuji; Hayashi, Takeshi; Kato, Ritsushi; Tanahashi, Norio; Takao, Masaki

    2017-09-01

    The clinical characteristics of ischemic stroke in patients with a pacemaker (PM) are not well understood. Forty-six ischemic stroke patients with a PM were investigated retrospectively, and the impact of different pacing modes was compared. The patients were divided into a physiological pacing group (n = 22) and a ventricular pacing group (n = 24). The prevalence of atrial fibrillation (AF) was significantly higher in the ventricular pacing group (36% versus 75%; P = .008). The mean left atrial dimension was relatively large in the ventricular pacing group than in the physiological pacing group (44.5 ± 6.7 mm versus 39.1 ± 8.5 mm, respectively; P = .071). Twenty-four percent of the patients were receiving anticoagulants, whereas 41% of the patients were receiving antiplatelet drugs. Cardioembolism was the most common stroke subtype in both groups. Although there was no statistically significant difference, neurological severity on admission was higher in the ventricular pacing group than in the physiological pacing group (P = .061). Functional outcomes, excluding patients with transient ischemic attack or prior stroke, significantly declined in the ventricular pacing group compared with the physiological pacing group (P = .044). The avoidance of the ventricular pacing mode may result in improved clinical outcomes. In patients without persistent AF, it may be important to select physiological pacing instead of ventricular pacing to decrease potential stroke severity. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  11. Extraction of SelectSecure leads compared to conventional pacing leads in patients with congenital heart disease and congenital atrioventricular block.

    Science.gov (United States)

    Shepherd, Emma; Stuart, Graham; Martin, Rob; Walsh, Mark A

    2015-06-01

    SelectSecure™ pacing leads (Medtronic Inc) are increasingly being used in pediatric patients and adults with structural congenital heart disease. The 4Fr lead is ideal for patients who may require lifelong pacing and can be advantageous for patients with complex anatomy. The purpose of this study was to compare the extraction of SelectSecure leads with conventional (stylette-driven) pacing leads in patients with structural congenital heart disease and congenital atrioventricular block. The data on lead extractions from pediatric and adult congenital heart disease (ACHD) patients from August 2004 to July 2014 at Bristol Royal Hospital for Children and the Bristol Heart Institute were reviewed. Multivariable regression analysis was used to determine whether conventional pacing leads were associated with a more difficult extraction process. A total of 57 patients underwent pacemaker lead extractions (22 SelectSecure, 35 conventional). No deaths occurred. Mean age at the time of extraction was 17.6 ± 10.5 years, mean weight was 47 ± 18 kg, and mean lead age was 5.6 ± 2.6 years (range 1-11 years). Complex extraction (partial extraction/femoral extraction) was more common in patients with conventional pacing leads at univariate (P < .01) and multivariate (P = .04) levels. Lead age was also a significant predictor of complex extraction (P < .01). SelectSecure leads can be successfully extracted using techniques that are used for conventional pacing leads. They are less likely to be partially extracted and are less likely to require extraction using a femoral approach compared with conventional pacing leads. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  12. Heart failure in patients with sick sinus syndrome treated with single lead atrial or dual-chamber pacing

    DEFF Research Database (Denmark)

    Riahi, Sam; Nielsen, Jens Cosedis; Hjortshøj, Søren

    2012-01-01

    AIMS: Previous studies indicate that ventricular pacing may precipitate heart failure (HF). We investigated occurrence of HF during long-term follow-up among patients with sick sinus syndrome (SSS) randomized to AAIR or DDDR pacing. Furthermore, we investigated effects of percentage of ventricular...... patients (17%) with the leads in a non-apical position, HR 0.67, CI 0.45-1.00, P = 0.05. After adjustments this difference was non-significant. The incidence of HF was not associated with %VP (P = 0.57).CONCLUSION: In patients with SSS, HF was not associated with pacing mode, %VP, or ventricular lead...... localization. This suggests that DDDR pacing is safe in patients with SSS without precipitating HF....

  13. Right Ventricular Pacing and Sensing Function in High Posterior Septal and Apical Lead Placement in Cardiac Resynchronization Therapy

    Directory of Open Access Journals (Sweden)

    H.M. Kristiansen, MD

    2012-01-01

    Conclusions: The RV-HS lead position demonstrated stable and acceptable long-term pacing and sensing function, with rates of complications comparable to conventional RV-A lead position in CRT. The RV-HS lead position is feasible in CRT-P.

  14. Failed anti-tachycardia pacing can be used to differentiate atrial arrhythmias from ventricular tachycardia in implantable cardioverter-defibrillators.

    Science.gov (United States)

    Michael, Kevin A; Enriquez, Andres; Baranchuk, Adrian; Haley, Charlotte; Caldwell, Jane; Simpson, Christopher S; Abdollah, Hoshiar; Redfearn, Damian P

    2015-01-01

    Atrial fibrillation/tachycardia (AF/AT) may result in inappropriate therapies in implantable cardioverter-defibrillators (ICDs). The post-pacing interval (PPI) and tachycardia cycle length difference (PPI - TCL) has been previously demonstrated to indicate the proximity of the pacing site to a tachycardia origin. We postulated that the PPI and PPI - TCL would be greater in AT/AF vs. ventricular tachycardia (VT) after episodes of failed anti-tachycardia pacing (ATP). This was a single-centre, retrospective study evaluating consecutive patients implanted with dual (DR)/biventricular (BIV) ICDs. Stored electrograms were used to determine whether the ATP captured the arrhythmia and the arrhythmia did not present with primary or secondary termination. Measurements were done using manual calipers. A total of 155 patients were included. There were 79 BIV and 76 DR devices. In total, 39 episodes were identified in 20 patients over a 23-month follow-up period. A total of 76 sequences of ATP (burst/ramp) were delivered, 28 (37%) of them inappropriate. Fifty-one events (18 AT/AF and 33 VT) were compared. The mean PPI was 693 ± 96 vs. 512 ± 88 ms (P failed ATP differs significantly between AF/AT and VT and are therefore useful indices to discriminate between supraventricular tachycardia and VT in ICDs. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  15. Long-Term Evaluation of Biotronik Linox and Linox(smart) Implantable Cardioverter Defibrillator Leads.

    Science.gov (United States)

    Good, Eric D; Cakulev, Ivan; Orlov, Michael V; Hirsh, David; Simeles, John; Mohr, Kelly; Moll, Phil; Bloom, Heather

    2016-06-01

    Expert consensus holds that post-market, systematic surveillance of ICD leads is essential to ensure confirmation of adequate lead performance. GALAXY (NCT00836589) and CELESTIAL (NCT00810264) are ongoing multicenter, prospective, non-randomized registries conducted to confirm the long-term safety and reliability of Biotronik leads. ICD and CRT-D patients are followed for Linox and Linox(smart) ICD lead performance and safety for 5 years post-implant. All procedural and system-related adverse events (AEs) were assessed at each follow-up, along with lead electrical parameters. An independent CEC of EPs adjudicated AEs to determine AE category and lead relatedness. The analysis used categories of lead observations per ISO 5841-2 (Third edition). A total of 3,933 leads were implanted in 3,840 patients (73.0% male, mean age 67.0 ± 12.2 years) at 146 US centers. The estimated cumulative survival probability was 96.3% at 5 years after implant for Linox leads and 96.6% at 4 years after implant for Linox(smart) leads. A comparison of the Linox and Linox(smart) survival functions did not find evidence of a difference (P = 0.2155). The most common AEs were oversensing (23, 0.58%), conductor fracture (14, 0.36%), failure to capture (13, 0.33%), lead dislodgement (12, 0.31%), insulation breach (10, 0.25%), and abnormal pacing impedance (8, 0.20%). Linox and Linox(smart) ICD leads are safe, reliable and infrequently associated with lead-related AEs. Additionally, estimated cumulative survival probability is clinically acceptable and well within industry standards. Ongoing data collection will confirm the longer-term safety and performance of the Linox family of ICD leads. © 2016 Wiley Periodicals, Inc.

  16. Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement

    Directory of Open Access Journals (Sweden)

    Naga VA Kommuri

    2010-01-01

    Full Text Available Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.

  17. Leadless Cardiac Pacemaker Implantation After Lead Extraction in Patients With Severe Device Infection.

    Science.gov (United States)

    Kypta, Alexander; Blessberger, Hermann; Kammler, Juergen; Lambert, Thomas; Lichtenauer, Michael; Brandstaetter, Walter; Gabriel, Michael; Steinwender, Clemens

    2016-09-01

    Conventional pacemaker therapy is limited by short- and long-term complications, most notably device infection. Transcatheter pacing systems (TPS) may be beneficial in this kind of patients as they eliminate the need for a device pocket and leads and thus may reduce the risk of re-infection. We assessed a novel procedure in 6 patients with severe device infection who were pacemaker dependent. After lead extraction a single chamber TPS was implanted into the right ventricle. Of the 6 patients who underwent lead extraction due to severe device infection at our institution, 3 were diagnosed with a pocket infection only, whereas the other 3 showed symptoms of both pocket and lead infection. Successful lead extraction and TPS implantation was accomplished in all patients. Four patients were bridged with a temporary pacemaker between 2 hours and 2 days after lead extraction, whereas 2 patients had the TPS implanted during the same procedure just before traditional pacemaker system removal. All patients stayed free of infection during the follow-up period of 12 weeks. An additional positron emission tomography scan was performed in each patient and indicated no signs of an infection around the TPS. Transcather pacemaker implantation was safe and feasible in 6 patients and did not result in re-infection even if implanted before removal of the infected pacemaker system within the same procedure. Therefore, implantation of a TPS may be an option for patients with severe device infection, especially in those with blocked venous access or who are pacemaker dependent. © 2016 Wiley Periodicals, Inc.

  18. Rejection of atrial sensing artifacts by a pacing lead with short tip-to-ring spacing.

    Science.gov (United States)

    Nash, A; Fröhlig, G; Taborsky, M; Stammwitz, E; Maru, F; Bouwens, L H M; Celiker, C

    2005-01-01

    The ability of a new pacing lead design, with a 10 mm tip-to-ring spacing, to facilitate rejection of sensed far field R-waves and myopotentials was evaluated. Measurements were performed in 66 patients. The occurrence of far field R-wave sensing and myopotential sensing was determined by means of the surface ECG and the ECG markers provided by the pacemaker. At an atrial sensitivity of 0.25 mV and an atrial blanking of 50 ms far field R-wave sensing was observed in 12 patients (18.2%) and at an atrial sensitivity of 1.0 mV no far-field R-wave sensing was observed. Myopotentials were sensed in 3 patients. In all patients the measured P-wave amplitude was at least twice the estimated amplitude of the far field R-wave at an atrial blanking of 50 ms. The results from this study show that a small tip-to-ring spacing allows for programming of a high atrial sensitivity and short atrial blanking with an acceptably low risk for atrial artifact sensing.

  19. Impact of right-ventricular apical pacing on the optimal left-ventricular lead positions measured by phase analysis of SPECT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Hung, Guang-Uei; Huang, Jin-Long; Lin, Wan-Yu; Tsai, Shih-Chung; Wang, Kuo-Yang; Chen, Shih-Ann; Lloyd, Michael S.; Chen, Ji

    2014-01-01

    The use of SPECT phase analysis to optimize left-ventricular (LV) lead positions for cardiac resynchronization therapy (CRT) was performed at baseline, but CRT works as simultaneous right ventricular (RV) and LV pacing. The aim of this study was to assess the impact of RV apical (RVA) pacing on optimal LV lead positions measured by SPECT phase analysis. This study prospectively enrolled 46 patients. Two SPECT myocardial perfusion scans were acquired under sinus rhythm with complete left bundle branch block and RVA pacing, respectively, following a single injection of 99m Tc-sestamibi. LV dyssynchrony parameters and optimal LV lead positions were measured by the phase analysis technique and then compared between the two scans. The LV dyssynchrony parameters were significantly larger with RVA pacing than with sinus rhythm (p ∝0.01). In 39 of the 46 patients, the optimal LV lead positions were the same between RVA pacing and sinus rhythm (kappa = 0.861). In 6 of the remaining 7 patients, the optimal LV lead positions were along the same radial direction, but RVA pacing shifted the optimal LV lead positions toward the base. The optimal LV lead positions measured by SPECT phase analysis were consistent, no matter whether the SPECT images were acquired under sinus rhythm or RVA pacing. In some patients, RVA pacing shifted the optimal LV lead positions toward the base. This study supports the use of baseline SPECT myocardial perfusion imaging to optimize LV lead positions to increase CRT efficacy. (orig.)

  20. Correlation of geomagnetic activity with implantable cardioverter defibrillator shocks and antitachycardia pacing

    Czech Academy of Sciences Publication Activity Database

    Ebrille, E.; Konecny, T.; Konecny, D.; Špaček, R.; Jones, P.; Ambrož, Pavel; DeSimone, C.V.; Powel, B.D.; Hayes, D.L.; Friedman, P.A.; Asirvatham, S.J.

    2015-01-01

    Roč. 90, č. 2 (2015), s. 202-208 ISSN 0025-6196 Institutional support: RVO:67985815 Keywords : geomagnetic activity * implantable cardioverter defibrillator Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 5.920, year: 2015

  1. Cardiac implantable electronic device lead extraction using the lead-locking device system: keeping it simple, safe, and inexpensive with mechanical tools and local anesthesia.

    Science.gov (United States)

    Manolis, Antonis S; Georgiopoulos, Georgios; Metaxa, Sofia; Koulouris, Spyridon; Tsiachris, Dimitris

    2017-10-01

    We have previously reported our successful approach for percutaneous cardiac implantable electronic device (CIED) lead extraction using inexpensive tools, which we have continued over the years. Herein we report the results of the systematic use of a unique stylet, the lead-locking device (LLD), which securely locks the entire lead lumen, aided with non-powered telescoping sheaths in 54 patients to extract 98 CIED leads. This prospective observational clinical study included 38 men and 16 women aged 68.9±13.1 years undergoing lead extraction for device infection (n=46), lead malfunction (n=5), or prior to defibrillator implant (n=3). Leads were in place for 6.7±4.3 years. Infections were more commonly due to Staphylococcus species (n=40). There were 78 pacing (31 ventricular, 37 atrial, 4 VDD, and 6 coronary sinus leads) and 20 defibrillating leads. Using simple traction (6 leads) and the LLD stylets (92 leads) aided with telescoping sheaths (15 patients), 96 (98%) leads in 52 (96.3%) patients were successfully removed, with all but one leads removed using a subclavian approach; in 1 patient, the right femoral approach was also required. In 2 patients, distal fragments from one ventricular pacing and one defibrillating lead could not be removed. Finally, lead removal was completely (52/54) (96.3%) or partially (2/54) (3.7%) successful in 54 patients for 96 of 98 leads (98%) without major complications. Percutaneous lead extraction can be successful with mechanical tools using the LLD locking stylet aided with non-powered telescoping sheaths through a simplified, safe, and inexpensive procedure using local anesthesia.

  2. Bachmann's Bundle Pacing not Only Improves Interatrial Conduction but Also Reduces the Need for Ventricular Pacing.

    Science.gov (United States)

    Sławuta, Agnieszka; Kliś, Magdalena; Skoczyński, Przemysław; Bańkowski, Tomasz; Moszczyńska-Stulin, Joanna; Gajek, Jacek

    2016-01-01

    Patients treated for sick sinus syndrome may have interatrial conduction disorder leading to atrial fibrillation. This study was aimed to assess the influence of the atrial pacing site on interatrial and atrioventricular conduction as well as the percentage of ventricular pacing in patients with sick sinus syndrome implanted with atrioventricular pacemaker. The study population: 96 patients (58 females, 38 males) aged 74.1 ± 11.8 years were divided in two groups: Group 1 (n = 44) with right atrial appendage pacing and group 2 (n = 52) with Bachmann's area pacing. We assessed the differences in atrioventricular conduction in sinus rhythm and atrial 60 and 90 bpm pacing, P-wave duration and percentage of ventricular pacing. No differences in baseline P-wave duration in sinus rhythm between the groups (102.4 ± 17 ms vs. 104.1 ± 26 ms, p = ns.) were noted. Atrial pacing 60 bpm resulted in longer P-wave in group 1 vs. group 2 (138.3 ± 21 vs. 106.1 ± 15 ms, p < 0.01). The differences between atrioventricular conduction time during sinus rhythm and atrial pacing at 60 and 90 bpm were significantly longer in patients with right atrial appendage vs. Bachmann's pacing (44.1 ± 17 vs. 9.2 ± 7 ms p < 0.01 and 69.2 ± 31 vs. 21.4 ± 12 ms p < 0.05, respectively). The percentage of ventricular pacing was higher in group 1 (21 vs. 4%, p < 0.01). Bachmann's bundle pacing decreases interatrial and atrioventricular conduction delay. Moreover, the frequency-dependent atrioventricular conduction lengthening is much less pronounced during Bachmann's bundle pacing. Right atrial appendage pacing in sick sinus syndrome patients promotes a higher percentage of ventricular pacing.

  3. Leadless Cardiac Pacemakers: Current status of a modern approach in pacing

    Directory of Open Access Journals (Sweden)

    Skevos Sideris

    2017-11-01

    Full Text Available Since the first transvenous pacemaker implantation, which took place 50 years ago, important progress has been achieved in pacing technology. Consequently, at present, more than 700,000 pacemakers are implanted annually worldwide. However, conventional pacemakers' implantation has a non-negligible risk of periprocedural and long-term complications associated with the transvenous leads and pacemaker pocket. Recently, leadless pacing systems have emerged as a therapeutic alternative to conventional pacing systems that provide therapy for patients with bradyarrhythmias, while eliminating potential transvenous lead- and pacemaker pocket-related complications. Initial studies have demonstrated favorable efficacy and safety of currently developed leadless pacing systems, compared to transvenous pacemakers. In the present paper, we review the current evidence and highlight the advantages and disadvantages of this novel technology. New technological advances may allow the next generation of leadless pacemakers to further expand, thereby offering a wireless cardiac pacing in future. Keywords: cardiac pacing, pacemaker, leadless pacemaker, bradycardia

  4. Temperature and fluence effects in lead implanted cobalt single crystals

    International Nuclear Information System (INIS)

    Johansen, A.; Sarholt-Kristensen, L.; Johnson, E.; Steenstrup, S.; Chernysh, V.S.

    1988-01-01

    The channeled sputtering yields of the hcp and fcc phases of cobalt depend on the crystal structure and the radiation induced damage. Earlier irradiations of cobalt with argon ions channeled in the hcp direction give sputtering yields higher than expected in the temperature range 100-350deg C. This effect was attributed to a combination of radiation induced damage and a possible implantation induced hcp --> fcc phase transition. Sputtering yields for cobalt single crystals irradiated with 150 keV Pb + ions along the direction of the hcp phase and the direction of the fcc phase have been measured using the weightloss method. The radiation damage and the amount of lead retained in the implanted surface has been investigated by 'in situ' RBS/channeling analysis. Measured partial sputtering yields of lead ≅ 1 atom/ion indicate preferential sputtering of lead atoms. (orig.)

  5. Three-dimensional binding sites volume assessment during cardiac pacing lead extraction

    Directory of Open Access Journals (Sweden)

    Bich Lien Nguyen

    2015-07-01

    Conclusions: Real-time 3D binding sites assessment is feasible and improves transvenous lead extraction outcomes. Its role as a complementary information requires extensive validation, and might be beneficial for a tailored strategy.

  6. Transesophageal Echocardiography-Guided Epicardial Left Ventricular Lead Placement by Video-Assisted Thoracoscopic Surgery in Nonresponders to Biventricular Pacing and Previous Chest Surgery.

    Science.gov (United States)

    Schroeder, Carsten; Chung, Jane M; Mackall, Judith A; Cakulev, Ivan T; Patel, Aaron; Patel, Sunny J; Hoit, Brian D; Sahadevan, Jayakumar

    2018-06-14

    The aim of the study was to study the feasibility, safety, and efficacy of transesophageal echocardiography-guided intraoperative left ventricular lead placement via a video-assisted thoracoscopic surgery approach in patients with failed conventional biventricular pacing. Twelve patients who could not have the left ventricular lead placed conventionally underwent epicardial left ventricular lead placement by video-assisted thoracoscopic surgery. Eight patients had previous chest surgery (66%). Operative positioning was a modified far lateral supine exposure with 30-degree bed tilt, allowing for groin and sternal access. To determine the optimal left ventricular location for lead placement, the left ventricular surface was divided arbitrarily into nine segments. These segments were transpericardially paced using a hand-held malleable pacing probe identifying the optimal site verified by transesophageal echocardiography. The pacing leads were screwed into position via a limited pericardiotomy. The video-assisted thoracoscopic surgery approach was successful in all patients. Biventricular pacing was achieved in all patients and all reported symptomatic benefit with reduction in New York Heart Association class from III to I-II (P = 0.016). Baseline ejection fraction was 23 ± 3%; within 1-year follow-up, the ejection fraction increased to 32 ± 10% (P = 0.05). The mean follow-up was 566 days. The median length of hospital stay was 7 days with chest tube removal between postoperative days 2 and 5. In patients who are nonresponders to conventional biventricular pacing, intraoperative left ventricular lead placement using anatomical and functional characteristics via a video-assisted thoracoscopic surgery approach is effective in improving heart failure symptoms. This optimized left ventricular lead placement is feasible and safe. Previous chest surgery is no longer an exclusion criterion for a video-assisted thoracoscopic surgery approach.

  7. Ventricular Pacing via the Coronary Sinus in a Patient with a Mechanical Tricuspid Valve Prosthesis

    Directory of Open Access Journals (Sweden)

    Janice Swampillai, MD

    2011-01-01

    Full Text Available Implantation of a transvenous endocardial pacing lead in the right ventricle is contra-indicated after mechanical tricuspid valve replacement; therefore a surgical approach to the epicardium is usually required. This case report describes ventricular pacing via a branch of the coronary sinus in a patient with mechanical mitral, aortic and tricuspid valve replacements. In conclusion, this approach is minimally invasive, provides effective ventricular stimulation with low pacing threshold and stable lead position, and is a feasible option when transvenous right ventricular pacing is not possible.

  8. Recommendations for pacemaker implantation for the treatment of atrial tachyarrhythmias and resynchronisation therapy for heart failure: A report from the task force on pacemaker indications of the Dutch Working Group on Cardiac Pacing.

    Science.gov (United States)

    van Hemel, N M; Dijkman, B; de Voogt, W G; Beukema, W P; Bosker, H A; de Cock, C C; Jordaens, L J L M; van Gelder, I C; van Gelder, L M; van Mechelen, R; Ruiter, J H; Sedney, M I; Slegers, L C

    2004-01-01

    Today, new pacing algorithms and stimulation methods for the prevention and interruption of atrial tachyarrhythmias can be applied on patients who need bradycardia pacing for conventional reasons. In addition, biventricular pacing as additive treatment for patients with severe congestive heart failure due to ventricular systolic dysfunction and prolonged intraventricular conduction has shown to improve symptoms and reduce hospital admissions. These new pacing technologies and the optimising of the pacing programmes are complex, expensive and time-consuming. Based on many clinical studies the indications for these devices are beginning to emerge. To support the cardiologist's decision-making and to prevent waste of effort and resources, the 'ad hoc committee' has provided preliminary recommendations for implantable devices to treat atrial tachyarrhythmias and to extend the treatment of congestive heart failure respectively.

  9. Optimal pacing for right ventricular and biventricular devices: minimizing, maximizing, and right ventricular/left ventricular site considerations.

    Science.gov (United States)

    Gillis, Anne M

    2014-10-01

    The results from numerous clinical studies provide guidance for optimizing outcomes related to RV or biventricular pacing in the pacemaker and ICD populations. (1) Programming algorithms to minimize RV pacing is imperative in patients with dual-chamber pacemakers who have intrinsic AV conduction or intermittent AV conduction block. (2) Dual-chamber ICDs should be avoided in candidates without an indication for bradycardia pacing. (3) Alternate RV septal pacing sites may be considered at the time of pacemaker implantation. (4) Biventricular pacing may be beneficial in some patients with mild LV dysfunction. (5) LV lead placement at the site of latest LV activation is desirable. (6) Programming CRT systems to achieve biventricular/LV pacing >98.5% is important. (7) Protocols for AV and VV optimization in patients with CRT are not recommended after device implantation but may be considered for CRT nonresponders. (8) Novel algorithms to maximize the benefit of CRT are in evolution further.

  10. Effect of ion implantation on the corrosion behavior of lead and a lead-antimony alloy

    International Nuclear Information System (INIS)

    Zhang, S.T.; Kong, F.P.; Muller, R.H.

    1994-01-01

    Ion implantation of different metals in Pb and Pb-4% Sb has been found to improve the open-circuit corrosion resistance of the two metals in 5M H 2 SO 4 . Titanium ions were implanted under different conditions of ion dose and ion energy. Optimum implantation conditions resulted in an up to 72-fold reduction of corrosion currents. The implantation of V, Cr, Ni, and W has been investigated for one implantation condition and has also resulted in decreased corrosion currents. The corrosion behavior was characterized by the current response to small anodic potential steps. Surface analysis and depth profiles have shown the importance of the spatial distribution of the implanted ions for their effects on the anodic and cathodic parts of the corrosion reactions

  11. Where Does It Lead? Imaging Features of Cardiovascular Implantable Electronic Devices on Chest Radiograph and CT

    Energy Technology Data Exchange (ETDEWEB)

    Lanzman, Rotem S.; Blondin, Dirk; Furst, Gunter; Scherer, Axel; R Miese, Falk; Kroepil, Patric [University of Duesseldorf, Medical Faculty, 40225 Duesseldorf (Germany); Winter, Joachim [University Hospital Duesseldorf, 40225 Duesseldorf (Germany); Abbara, Suhny [Massachusetts General Hospital, Boston, MA (US)

    2011-10-15

    Pacemakers and implantable cardioverter defibrillators (ICDs) are being increasingly employed in patients suffering from cardiac rhythm disturbances. The principal objective of this article is to familiarize radiologists with pacemakers and ICDs on chest radiographs and CT scans. Therefore, the preferred lead positions according to pacemaker types and anatomic variants are introduced in this study. Additionally, the imaging features of incorrect lead positions and defects, as well as complications subsequent to pacemaker implantation are demonstrated herein.

  12. Where Does It Lead? Imaging Features of Cardiovascular Implantable Electronic Devices on Chest Radiograph and CT

    International Nuclear Information System (INIS)

    Lanzman, Rotem S.; Blondin, Dirk; Furst, Gunter; Scherer, Axel; R Miese, Falk; Kroepil, Patric; Winter, Joachim; Abbara, Suhny

    2011-01-01

    Pacemakers and implantable cardioverter defibrillators (ICDs) are being increasingly employed in patients suffering from cardiac rhythm disturbances. The principal objective of this article is to familiarize radiologists with pacemakers and ICDs on chest radiographs and CT scans. Therefore, the preferred lead positions according to pacemaker types and anatomic variants are introduced in this study. Additionally, the imaging features of incorrect lead positions and defects, as well as complications subsequent to pacemaker implantation are demonstrated herein.

  13. Right ventricular perforation by a passive-fixation pacemaker lead two weeks after implantation

    Directory of Open Access Journals (Sweden)

    Azeem S. Sheikh, BSc, MBBS, FCPS, MRCP

    2014-12-01

    Full Text Available Myocardial perforation is a rare complication of permanent pacemaker implantation. While most of the perforations occur at the time of implantation or within the first 24 h, delayed myocardial perforations are very rare. The clinical course is extremely variable with some patients presenting completely asymptomatic, while others can develop cardiac tamponade and haemodynamic instability. We report an unusual case of a subacute ventricular perforation caused by a passive-fixation lead two weeks after implantation and we successfully managed to extract the lead under local anaesthesia, without the patient undergoing surgery, as recommended in the previously published reports.

  14. Modifying the conductivity of polypyrrole through low-energy lead ion implantation

    International Nuclear Information System (INIS)

    Booth, Marsilea Adela; Leveneur, Jérôme; Costa, Alexsandro Santos; Kennedy, John; Harbison, SallyAnn; Travas-Sejdic, Jadranka

    2012-01-01

    Interest lies in the creation of novel nanocomposite materials obtained through mixing, impregnation or incorporation techniques. One such technique is ion implantation which possesses the potential for retaining properties from the base material and implanted material as well as any effects observed from combining the two. To this end low-energy (15 keV) implantation of lead ions of various fluences was performed in conducting polypyrrole films. The presence of lead-rich particles was evidenced through transmission electron microscopy. An interesting trend was observed between fluence and conductivity. Of the fluences tested, the optimum fluences of lead ion implantation in polypyrrole films for enhanced conductivity are 5 × 10 14 at. cm −2 and 2 × 10 15 at. cm −2 . The conductivity and stability appear to result from a combination of effects: polymer degradation arising from ion beam damage, an increase in charge-carriers (dications) present after implantation and precipitation of Pb-rich nanoparticles. Monitoring conductivity over time showed increased retention of conductivity levels after lead implantation. Improvements in stability for polypyrrole open avenues for application and bring polypyrrole one step closer to practical use. A mechanism is suggested for this advantageous retained conductivity. -- Highlights: ► Implanted and characterized polypyrrole films with Pb ions at different fluences. ► Samples indicate high conductivity when implanted with particular fluences. ► Increase in charge carriers and precipitation of conductive Pb-rich phase. ► Conductivity stability is higher for some implanted fluences than for pristine polypyrrole.

  15. Leadless Pacing: Current State and Future Direction.

    Science.gov (United States)

    Merkel, Matthias; Grotherr, Philipp; Radzewitz, Andrea; Schmitt, Claus

    2017-12-01

    Leadless pacing is now an established alternative to conventional pacing with subcutaneous pocket and transvenous lead for patients with class I or II single-chamber pacing indication. Available 12-month follow-up data shows a 48% fewer major complication rate in patients with Micra™ compared to a historical control group in a nonrandomized study [1]. There is one system with Food and Drug Administration (FDA) approval and two with the Communauté Européenne (CE) mark. The OPS code for the implantation is 8-83d.3 and the procedure has recently been rated as a "new Examination and Treatment Method (NUB)" in the German DRG system, meaning adequate reimbursement is negotiable with health insurance providers. The systems offer similar generator longevity and programming possibilities as conventional pacemaker systems, including rate response, remote monitoring, and MRI safety. The biggest downsides to date are limitations to single-chamber stimulation, lack of long-time data, and concerns of handling of the system at the end of its life span. However, implant procedure complication rates and procedure times do not exceed conventional pacemaker operations, and proper training and patient selection is provided.

  16. Temporary pacing

    Directory of Open Access Journals (Sweden)

    L.J. Workman

    1983-09-01

    Full Text Available Artificial cardiac pacing, the use of electrical stimuli to cause contraction of heart muscle, is a sophisticated therapeutic and diagnostic tool. Its rapid technologic improvement since first developed in the late 1930’s by Hyman, has made it possible not only to avoid certain cases of death due to heart block, but also to extend and improve the quality of life. Pacemaker therapy is generally used to treat heart rate or rhythm disturbances, being either tachy- or bradyarrhythmias that produce a detrimental drop in cardiac output. Of the many different types of pacemakers and electrodes currently available, ventricular demand pacing is the most commonly used.

  17. Primer implante de electrodo de estimulación selectiva del haz de His en Colombia: Reporte de dos casos First implantation of selective his bundle pacing in Colombia: Report of two cases

    Directory of Open Access Journals (Sweden)

    Jorge E Velásquez

    2010-06-01

    Full Text Available Se conoce que la estimulación en el ápex del ventrículo derecho produce disincronía ventricular y muchas veces los pacientes desarrollan miocardiopatía dilatada, lo que ha llevado a realizar una estimulación más fisiológica. Con el reciente desarrollo tecnológico de los electrodos para la estimulación selectiva del haz de His (fisiológica, se quiere mostrar la experiencia en el implante de este tipo de electrodos en los dos primeros casos del servicio de electrofisiología de la Clínica Medellín.Pacing in the right ventricular apex is known to produce ventricular dysynchrony and patients often develop dilated cardiomiopathy. For this reason, a more physiological stimulation has been performed. With the recent technological development of electrodes for selective stimulation of the His bundle, we want to show the experience of this type of implantation in the first two cases made in the electrophysiology laboratory in Medellin.

  18. New approach for T-wave peak detection and T-wave end location in 12-lead paced ECG signals based on a mathematical model.

    Science.gov (United States)

    Madeiro, João P V; Nicolson, William B; Cortez, Paulo C; Marques, João A L; Vázquez-Seisdedos, Carlos R; Elangovan, Narmadha; Ng, G Andre; Schlindwein, Fernando S

    2013-08-01

    This paper presents an innovative approach for T-wave peak detection and subsequent T-wave end location in 12-lead paced ECG signals based on a mathematical model of a skewed Gaussian function. Following the stage of QRS segmentation, we establish search windows using a number of the earliest intervals between each QRS offset and subsequent QRS onset. Then, we compute a template based on a Gaussian-function, modified by a mathematical procedure to insert asymmetry, which models the T-wave. Cross-correlation and an approach based on the computation of Trapezium's area are used to locate, respectively, the peak and end point of each T-wave throughout the whole raw ECG signal. For evaluating purposes, we used a database of high resolution 12-lead paced ECG signals, recorded from patients with ischaemic cardiomyopathy (ICM) in the University Hospitals of Leicester NHS Trust, UK, and the well-known QT database. The average T-wave detection rates, sensitivity and positive predictivity, were both equal to 99.12%, for the first database, and, respectively, equal to 99.32% and 99.47%, for QT database. The average time errors computed for T-wave peak and T-wave end locations were, respectively, -0.38±7.12 ms and -3.70±15.46 ms, for the first database, and 1.40±8.99 ms and 2.83±15.27 ms, for QT database. The results demonstrate the accuracy, consistency and robustness of the proposed method for a wide variety of T-wave morphologies studied. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Pacemaker Implantation Associated Myocardial Micro-Damage: A Randomised Comparison between Active and Passive Fixation Leads.

    Science.gov (United States)

    Blažek, Patrick; Ferri-Certić, Jerko; Vražić, Hrvoje; Lennerz, Carsten; Grebmer, Christian; Kaitani, Kazuaki; Karch, Martin; Starčević, Boris; Semmler, Verena; Kolb, Christof

    2018-03-20

    Fixation of the pacemaker leads during pacemaker implantation leads to an increase of cardiac Troponin T (cTnT) that can be interpreted as a sign of minimal myocardial damage. This trial evaluates whether the mechanism type of lead fixation influences the magnitude of cTnT release. Patients having a de-novo cardiac pacemaker implantation or a lead revision were centrally randomized to receive either a ventricular lead with an active (screw) or passive (tine) fixation mechanism. High-sensitive Troponin T (hsTnT) was determined on the day of the procedure beforehand and on the following day. 326 Patients (median age (IQR) 75.0 (69.0-80.0) years, 64% male) from six international centers were randomized to receive ventricular leads with an active (n = 166) or passive (n = 160) fixation mechanism. Median (IQR) hsTnT levels increased by 0.009 (0.004-0.021) ng/ml in the group receiving screw-in ventricular leads and by 0.008 (0.003-0.030) ng/ml in the group receiving tined ventricular leads (n.s.). In conclusion pacemaker implantations are followed by a release of hsTnT. The choice between active or passive fixation ventricular leads does not have a significant influence on the extent of myocardial injury and the magnitude of hsTnT release.

  20. Analysis of induced electrical currents from magnetic field coupling inside implantable neurostimulator leads

    Directory of Open Access Journals (Sweden)

    Seidman Seth J

    2011-10-01

    Full Text Available Abstract Background Over the last decade, the number of neurostimulator systems implanted in patients has been rapidly growing. Nearly 50, 000 neurostimulators are implanted worldwide annually. The most common type of implantable neurostimulators is indicated for pain relief. At the same time, commercial use of other electromagnetic technologies is expanding, making electromagnetic interference (EMI of neurostimulator function an issue of concern. Typically reported sources of neurostimulator EMI include security systems, metal detectors and wireless equipment. When near such sources, patients with implanted neurostimulators have reported adverse events such as shock, pain, and increased stimulation. In recent in vitro studies, radio frequency identification (RFID technology has been shown to inhibit the stimulation pulse of an implantable neurostimulator system during low frequency exposure at close distances. This could potentially be due to induced electrical currents inside the implantable neurostimulator leads that are caused by magnetic field coupling from the low frequency identification system. Methods To systematically address the concerns posed by EMI, we developed a test platform to assess the interference from coupled magnetic fields on implantable neurostimulator systems. To measure interference, we recorded the output of one implantable neurostimulator, programmed for best therapy threshold settings, when in close proximity to an operating low frequency RFID emitter. The output contained electrical potentials from the neurostimulator system and those induced by EMI from the RFID emitter. We also recorded the output of the same neurostimulator system programmed for best therapy threshold settings without RFID interference. Using the Spatially Extended Nonlinear Node (SENN model, we compared threshold factors of spinal cord fiber excitation for both recorded outputs. Results The electric current induced by low frequency RFID emitter

  1. Prolonged angina pectoris and persistent negative T waves in the precordial leads: response to atrial pacing and to methoxamine-induced hypertension

    International Nuclear Information System (INIS)

    Figueras, J.; Cinca, J.; Gutierrez, L.; Segura, R.; Rius, J.

    1983-01-01

    In 18 consecutive patients without a history of myocardial infarction (MI), prolonged angina pectoris with persistent negative T waves in the precordial leads was associated with a high frequency of in-hospital spontaneous angina (14 of 18, 78%), usually accompanied by S-T segment elevation, and occasionally in-hospital MI (4 of 18, 22%). Angina and MI always involved the electrocardiographic leads with negative T waves. Coronary arteriography, performed in 16 patients, revealed greater than or equal to 90% proximal diameter reduction of the left anterior descending (LAD) coronary artery in 14 patients. No patient had severe narrowing of all 3 major coronary arteries, but the 3 who had 100% LAD occlusion lacked collateral circulation. The ejection fraction was greater than or equal to 50% in 13 patients. Atrial pacing performed in 11 patients at an average rate of 142 beats/min produced a 1.0 mm S-T segment change in only 5 patients (45%), 3 of whom had an associated lactate production. Arterial systemic hypertension induced by methoxamine in 14 patients caused reversal of negative T waves without significant S-T segment shifts or chest pain and failed to elicit lactate extraction abnormalities in each of the 5 patients in whom it was determined. Thus, prolonged angina with persistent negative T waves in the precordial leads is almost invariably associated with a critical and proximal LAD obstruction, severe narrowing of 1 or 2 coronary arteries, and poor or absent collateral vessels

  2. Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room

    International Nuclear Information System (INIS)

    Kröpil, Patric; Lanzman, Rotem S.; Miese, Falk R.; Blondin, Dirk; Winter, Joachim; Scherer, Axel; Fürst, Günter

    2011-01-01

    We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 ± 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thus required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.

  3. Endocardial Pacemaker Implantation in Neonates and Infants

    Directory of Open Access Journals (Sweden)

    Canan Ayabakan

    2006-04-01

    Full Text Available Transvenous pacemaker lead implantation is the preferred method of pacing in adult patients. Lead performance and longevity are superior and the implantation approach can be performed under local anaesthetic with a very low morbidity. In children, and especially in neonates and infants, the epicardial route was traditionally chosen until the advent of smaller generators and lead implantation techniques that allowed growth of the child without lead displacement. Endocardial implantation is not universally accepted, however, as there is an incidence of venous occlusion of the smaller veins of neonates and infants with concerns for loss of venous access in the future. Growing experience with lower profile leads, however, reveals that endocardial pacing too can be performed with low morbidity and good long-term results in neonates and infants.

  4. Is the epicardial left ventricular lead implantation an alternative approach to percutaneous attempt in patients with Steinert disease? A case report

    Science.gov (United States)

    PAPA, ANDREA ANTONIO; RAGO, ANNA; PETILLO, ROBERTA; D’AMBROSIO, PAOLA; SCUTIFERO, MARIANNA; FEO, MARISA DE; MAIELLO, CIRO; PALLADINO, ALBERTO

    2017-01-01

    Steinert’s disease or Myotonic Dystrophy type 1 (DM1) is an autosomal dominant multisystemic disorder characterized by myotonia, muscle and facial weakness, cataracts, cognitive, endocrine and gastrointestinal involvement, and cardiac conduction abnormalities. Although mild myocardial dysfunction may be detected in this syndrome with age, overt myocardial dysfunction with heart failure is not frequent. Cardiac resynchronization therapy is an effective treatment to improve morbidity and reduce mortality in patients with DM1 showing intra-ventricular conduction delay and/or congestive heart failure. We report the case of a patient with Steinert disease showing an early onset ventricular dysfunction due to chronic right ventricular apical pacing, in which an epicardial left ventricular lead implantation was performed following the failure of the percutaneous attempt. As no relief in symptoms of heart failure, nor an improvement of left ventricular ejection fraction and reverse remodelling was observed six months later, the patient was addressed to the heart transplantation.

  5. Optical waveguides in fluoride lead silicate glasses fabricated by carbon ion implantation

    Science.gov (United States)

    Shen, Xiao-liang; Wang, Yue; Zhu, Qi-feng; Lü, Peng; Li, Wei-nan; Liu, Chun-xiao

    2018-03-01

    The carbon ion implantation with energy of 4.0 MeV and a dose of 4.0×1014 ions/cm2 is employed for fabricating the optical waveguide in fluoride lead silicate glasses. The optical modes as well as the effective refractive indices are measured by the prism coupling method. The refractive index distribution in the fluoride lead silicate glass waveguide is simulated by the reflectivity calculation method (RCM). The light intensity profile and the energy losses are calculated by the finite-difference beam propagation method (FD-BPM) and the program of stopping and range of ions in matter (SRIM), respectively. The propagation properties indicate that the C2+ ion-implanted fluoride lead silicate glass waveguide is a candidate for fabricating optical devices.

  6. Antiarrhythmic properties of atrial pacing.

    Science.gov (United States)

    Kliś, Magdalena; Sławuta, Agnieszka; Gajek, Jacek

    2017-01-01

    Bradycardia, atrial stretch and dilatation, autonomic nervous system disorders, and the presence of triggers such as atrial premature contractions, are factors which predispose a person to paroxysmal AF. Atrial pacing not only eliminates bradycardia but also prevents atrial premature contractions and dispersion of refractoriness, which are a substrate for atrial fibrillation. As the prolonged duration of atrial activation during pacing, especially from locations changing the physiological pattern of this activation (right atrium lateral wall, right atrium appendage), negatively influences both a mechanical and an electrical function of the atria, the atrial pacing site affects an atrial arrhythmogenesis. A conventional atrial lead location in the right atrium appendage causes non-physiological activation propagation, resulting in a prolongation of the activation time of both atria. This location is optimal according to a passive fixation of the atrial lead but the available contemporary active fixation leads could potentially be located in any area of the atrium. There is growing evidence of the benefit of pacing, imitating the physiological propagation of impulses within the atria. It seems that the Bachmann's bundle pacing is the best pacing site within the atria, not only positively influencing the atrial mechanical function but also best fulfilling the so-called atrial resynchronization function, in particular in patients with interatrial conduction delay. It can be effectively achieved using only one atrial electrode, and the slight shortening of atrioventricular conduction provides an additional benefit of this atrial pacing site.

  7. Short- and long-term performance of a tripolar down-sized single lead for implantable cardioverter defibrillator treatment: a randomized prospective European multicenter study. European Endotak DSP Investigator Group.

    Science.gov (United States)

    Sandstedt, B; Kennergren, C; Schaumann, A; Herse, B; Neuzner, J

    1998-11-01

    A new, thinner (10 Fr) and more flexible, single-pass transvenous endocardial ICD lead, Endotak DSP, was compared with a conventional lead, Endotak C, as a control in a prospective randomized multicenter study in combination with a nonactive can ICD. A total of 123 patients were enrolled, 55 of whom received a down-sized DSP lead. Lead-alone configuration was successfully implanted in 95% of the DSP patients vs 88% in the control group. The mean defibrillation threshold (DFT) was determined by means of a step-down protocol, and was identical in the two groups, 10.5 +/- 4.8 J in the DSP group versus 10.5 +/- 4.8 J in the control group. At implantation, the DSP mean pacing threshold was lower, 0.51 +/- 0.18 V versus 0.62 +/- 0.35 V (p < 0.05) in the control group, and the mean pacing impedance higher, 594 +/- 110 omega vs 523 +/- 135 omega (p < 0.05). During the follow-up period, the statistically significant difference in thresholds disappeared, while the difference in impedance remained. Tachyarrhythmia treatment by shock or antitachycardia pacing (ATP) was delivered in 53% and 41%, respectively, of the patients with a 100% success rate. In the DSP group, all 28 episodes of polymorphic ventricular tachycardia or ventricular fibrillation were converted by the first shock as compared to 57 of 69 episodes (83%) in the control group (p < 0.05). Monomorphic ventricular tachycardias were terminated by ATP alone in 96% versus 94%. Lead related problems were minor and observed in 5% and 7%, respectively. In summary, both leads were safe and efficacious in the detection and treatment of ventricular tachyarrhythmias. There were no differences between the DSP and control groups regarding short- or long-term lead related complications.

  8. Pneumothorax in cardiac pacing

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2012-01-01

    AIM: To identify risk factors for pneumothorax treated with a chest tube after cardiac pacing device implantation in a population-based cohort.METHODS AND RESULTS: A nationwide cohort study was performed based on data on 28 860 patients from the Danish Pacemaker Register, which included all Danish...... age was 77 years (25th and 75th percentile: 69-84) and 55% were male (n = 15 785). A total of 190 patients (0.66%) were treated for pneumothorax, which was more often in women [aOR 1.9 (1.4-2.6)], and in patients with age >80 years [aOR 1.4 (1.0-1.9)], a prior history of chronic obstructive pulmonary...

  9. Simple and effective solution for diaphragm pacing by that uses the transvenous femoral approach in a patient treated with cardiac resynchronization-defibrillator therapy: The wrapping method

    Directory of Open Access Journals (Sweden)

    Ahmet Taha Alper, Prof.

    2017-08-01

    Full Text Available The use of cardiac resynchronization therapy (CRT has become widespread in patients with heart failure who meet the criteria for implantation. Coronary sinus lead positioning is important to provide the intended biventricular stimulation. Diaphragm pacing is a lead-related complication which occurs secondary to phrenic nerve stimulation. We present the case of a 58-year-old male patient who had diaphragm pacing after CRT with defibrillator implantation. The complication was resolved by using the transvenous femoral approach with the wrapping method.

  10. Develop techniques for ion implantation of PLZT [lead-lanthanum-zirconate-titanate] for adaptive optics

    International Nuclear Information System (INIS)

    Batishko, C.R.; Brimhall, J.L.; Pawlewicz, W.T.; Stahl, K.A.; Toburen, L.H.

    1987-09-01

    Research was conducted at Pacific Northwest Laboratory to develop high photosensitivity adaptive optical elements utilizing ion implanted lanthanum-doped lead-zirconate-titanate (PLZT). One centimeter square samples were prepared by implanting ferroelectric and anti-ferroelectric PLZT with a variety of species or combinations of species. These included Ne, O, Ni, Ne/Cr, Ne/Al, Ne/Ni, Ne/O, and Ni/O, at a variety of energies and fluences. An indium-tin oxide (ITO) electrode coating was designed to give a balance of high conductivity and optical transmission at near uv to near ir wavelengths. Samples were characterized for photosensitivity; implanted layer thickness, index of refraction, and density; electrode (ITO) conductivity; and in some cases, residual stress curvature. Thin film anti-ferroelectric PLZT was deposited in a preliminary experiment. The structure was amorphous with x-ray diffraction showing the beginnings of a structure at substrate temperatures of approximately 550 0 C. This report summarizes the research and provides a sampling of the data taken during the report period

  11. Pacing-induced Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Alex Koo

    2017-10-01

    Full Text Available We present a case of pacing-induced cardiomyopathy. The patient presented with clinical symptoms of dyspnea, leg swelling, and orthopnea several months after a dual-chambered pacemaker was placed for third-degree heart block. The echocardiogram demonstrated a depressed ejection fraction. Coronary angiography was performed, which showed widely patent vessels. Single- and dual-chambered pacemakers create ventricular dyssynchrony, which in turn can cause structural, molecular changes leading to cardiomyopathy. With early intervention of biventricular pacemaker replacement, these changes can be reversible; thus, a timely diagnosis and awareness is warranted.

  12. The usefulness of panoramic radiography using a lead ruler for dental implant planning

    International Nuclear Information System (INIS)

    Lee, Sang Hee; Lee, Seong Geun; Kim, Sung Min; Oh, Kyong Seung; Huh, Jin Do; Joh, Young Duk

    2000-01-01

    If damage to the neurovascular bundle of the mandibular canal during dental implant surgery of the mandible is to be prevented, accurate measurement of the distance between the alveolar crest and the mandibular canal, as seen on panoramic radiographs, is important. The purpose of this study was to compare the accuracy of panoramic radiography using a lead ruler with that of computed tomography for the measurement of the distance between the alveolar crest and superior border of the mandibular canal and to evaluate the usefulness of panoramic radiography using a lead ruler. For control study, panoramic radiography of the dry mandible was undertaken using a lead ruler, and computed tomography was added. The distances between the alveolar crest and the superior border of the mandibular canal and between the alveolar crest and the lowest border of the body of the mandible were measured at the level of the 2nd premolar to the 3rd molar. These measurements were compared with actual measurements of the dry mandible in the same areas. The cases of 87 patients (49 men, 38 women; age range, 20-84 (mean, 42) years) who had undergone panoramic radiography using a lead ruler were reviewed. They were categorized according to sex, the presence of teeth, and whether under or over 50 years of age. All measurements were compared and analyzed using the Student t-test. Measured values obtained from a panoramic radiograph using a lead ruler (magnification:100.32% ± 5.92) and from a computed tomograph (magnification:100.22 ± 5.55) deviated less from actual measurements on the dry mandible (p greater than 0.05). The distance from the 2nd premolar to the 3rd molar was greater in male adults (19.62 mm ± 3.95) than in female (17.54 mm ± 4.04) (p less than 0.05), except the 3rd molar. In addition, the distance was greater in dentulous patients (18.81 mm ± 3.33) than in edentulous (16.23 mm ± 1.75) (p less than 0.05), except the 3rd molar. There was, however, no significant difference

  13. Optimal Implantation Depth and Adherence to Guidelines on Permanent Pacing to Improve the Results of Transcatheter Aortic Valve Replacement With the Medtronic CoreValve System: The CoreValve Prospective, International, Post-Market ADVANCE-II Study.

    Science.gov (United States)

    Petronio, Anna S; Sinning, Jan-Malte; Van Mieghem, Nicolas; Zucchelli, Giulio; Nickenig, Georg; Bekeredjian, Raffi; Bosmans, Johan; Bedogni, Francesco; Branny, Marian; Stangl, Karl; Kovac, Jan; Schiltgen, Molly; Kraus, Stacia; de Jaegere, Peter

    2015-05-01

    The aim of the CoreValve prospective, international, post-market ADVANCE-II study was to define the rates of conduction disturbances and permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement with the Medtronic CoreValve System (Minneapolis, Minnesota) using optimized implantation techniques and application of international guidelines on cardiac pacing. Conduction disturbances are a frequent complication of transcatheter aortic valve replacement. The rates of PPI in the published reports vary according to bioprosthesis type and the indications for PPI. The primary endpoint was the 30-day incidence of PPI with Class I/II indications when the Medtronic CoreValve System was implanted at an optimal depth (≤6 mm below the aortic annulus). The timing and resolution of all new-onset conduction disturbances were analyzed. A total of 194 patients were treated. The overall rate of PPI for Class I/II indications was 18.2%. An optimal depth was reached in 43.2% of patients, with a nonsignificantly lower incidence of PPI in patients with depths ≤6 mm, compared with those with deeper implants (13.3% vs. 21.1%; p = 0.14). In a paired analysis, new-onset left bundle branch block and first-degree atrioventricular block occurred in 45.4% and 39.0% of patients, respectively, and resolved spontaneously within 30 days in 43.2% and 73.9%, respectively. In patients with new PPI, the rate of intrinsic sinus rhythm increased from 25.9% at 7 days to 59.3% at 30 days (p = 0.004). Optimal Medtronic CoreValve System deployment and adherence to international guidelines on cardiac pacing are associated with a lower rate of new PPI after transcatheter aortic valve replacement, compared with results reported in previous studies. (CoreValve Advance-II Study: Prospective International Post-Market Study [ADVANCE II]; NCT01624870). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Contemporary rates and outcomes of single- vs. dual-coil implantable cardioverter defibrillator lead implantation: data from the Israeli ICD Registry.

    Science.gov (United States)

    Leshem, Eran; Suleiman, Mahmoud; Laish-Farkash, Avishag; Konstantino, Yuval; Glikson, Michael; Barsheshet, Alon; Goldenberg, Ilan; Michowitz, Yoav

    2017-09-01

    Dual-coil leads were traditionally considered standard of care due to lower defibrillation thresholds (DFT). Higher complication rates during extraction with parallel progression in implantable cardioverter defibrillator (ICD) technology raised questions on dual coil necessity. Prior substudies found no significant outcome difference between dual and single coils, although using higher rates of DFT testing then currently practiced. We evaluated the temporal trends in implantation rates of single- vs. dual-coil leads and determined the associated adverse clinical outcomes, using a contemporary nation-wide ICD registry. Between July 2010 and March 2015, 6343 consecutive ICD (n = 3998) or CRT-D (n = 2345) implantation patients were prospectively enrolled in the Israeli ICD Registry. A follow-up of at least 1 year of 2285 patients was available for outcome analysis. The primary endpoint was all-cause mortality. Single-coil leads were implanted in 32% of our cohort, 36% among ICD recipients, and 26% among CRT-D recipients. Secondary prevention indication was associated with an increased rate of dual-coil implantation. A significant decline in dual-coil leads with reciprocal incline of single coils was observed, despite low rates of DFT testing (11.6%) during implantation, which also declined from 31 to 2%. In the multivariate Cox model analysis, dual- vs. single-coil lead implantation was not associated with an increased risk of mortality [hazard ratio (HR) = 1.23; P= 0.33], heart failure hospitalization (HR = 1.34; P=0.13), appropriate (HR = 1.25; P= 0.33), or inappropriate ICD therapy (HR = 2.07; P= 0.12). Real-life rates of single-coil lead implantation are rising while adding no additional risk. These results of single-coil safety are reassuring and obtained, despite low and contemporary rates of DFT testing. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  15. Pulse of inflammatory proteins in the pregnant uterus of European polecats (Mustela putorius) leading to the time of implantation.

    Science.gov (United States)

    Lindeberg, Heli; Burchmore, Richard J S; Kennedy, Malcolm W

    2017-03-01

    Uterine secretory proteins protect the uterus and conceptuses against infection, facilitate implantation, control cellular damage resulting from implantation, and supply pre-implantation embryos with nutrients. Unlike in humans, the early conceptus of the European polecat ( Mustela putorius ; ferret) grows and develops free in the uterus until implanting at about 12 days after mating. We found that the proteins appearing in polecat uteri changed dramatically with time leading to implantation. Several of these proteins have also been found in pregnant uteri of other eutherian mammals. However, we found a combination of two increasingly abundant proteins that have not been recorded before in pre-placentation uteri. First, the broad-spectrum proteinase inhibitor α 2 -macroglobulin rose to dominate the protein profile by the time of implantation. Its functions may be to limit damage caused by the release of proteinases during implantation or infection, and to control other processes around sites of implantation. Second, lipocalin-1 (also known as tear lipocalin) also increased substantially in concentration. This protein has not previously been recorded as a uterine secretion in pregnancy in any species. If polecat lipocalin-1 has similar biological properties to that of humans, then it may have a combined function in antimicrobial protection and transporting or scavenging lipids. The changes in the uterine secretory protein repertoire of European polecats is therefore unusual, and may be representative of pre-placentation supportive uterine secretions in mustelids (otters, weasels, badgers, mink, wolverines) in general.

  16. Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure.

    Science.gov (United States)

    Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A

    2006-02-01

    Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.

  17. The Managed Ventricular pacing versus VVI 40 Pacing (MVP) Trial: clinical background, rationale, design, and implementation.

    Science.gov (United States)

    Sweeney, Michael O; Ellenbogen, Kenneth A; Miller, Elaine Hogan; Sherfesee, Lou; Sheldon, Todd; Whellan, David

    2006-12-01

    Implantable cardioverter defibrillators (ICDs) reduce mortality among appropriately selected patients who have had or are at risk for life-threatening ventricular arrhythmia. Right ventricular apical (RVA) pacing has been implicated in worsening heart failure and death. The optimal pacemaker mode for bradycardia support while minimizing unnecessary and potentially harmful RVA pacing has not been determined. The Managed Ventricular pacing vs. VVI 40 Pacing Trial (MVP) is a prospective, multicenter, randomized, single-blind, parallel, controlled clinical trial designed to establish whether atrial-based dual-chamber managed ventricular pacing mode (MVP) is equivalent or superior to back-up only ventricular pacing (VVI 40) among patients with standard indications for ICD therapy and no indication for bradycardia pacing. The MVP Trial is designed with 80% power to detect a 10% reduction in the primary endpoint of new or worsening heart failure or all-cause mortality in the MVP-treated group. Approximately 1,000 patients at 80 centers in the United States, Canada, Western Europe, and Israel will be randomized to MVP or VVI 40 pacing after successful implantation of a dual-chamber ICD. Heart failure therapies will be optimized in accordance with evidence-based guidelines. Prespecified secondary endpoints will include ventricular arrhythmias, atrial fibrillation, new indication for bradycardia pacing, health-related quality of life, and cost effectiveness. Enrollment began in October 2004 and concluded in April 2006. The study will be terminated upon recommendation of the Data Monitoring Committee or when the last patient enrolled and surviving has reached a minimum 2 years of follow-up. The MVP Trial will meet the clinical need for carefully designed prospective studies to define the benefits of atrial-based dual-chamber minimal ventricular pacing versus single-chamber ventricular pacing in conventional ICD patients.

  18. Patient-reported outcomes in Danish implantable cardioverter defibrillator patients with a Sprint Fidelis lead advisory notification

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Versteeg, Henneke; Nielsen, Jens Cosedis

    2011-01-01

    Few studies have investigated the association between implantable cardioverter defibrillators (ICDs) and lead advisory notifications and patient-reported outcomes (PROs). We examined (i) whether the mode used to inform patients about a device advisory is associated with PROs, and (ii) whether...... patients with a lead subject to a device advisory report poorer PROs than non-advisory controls....

  19. Mechanical fatigue resistance of an implantable branched lead system for a distributed set of longitudinal intrafascicular electrodes.

    Science.gov (United States)

    Pena, A E; Kuntaegowdanahalli, S S; Abbas, J J; Patrick, J; Horch, K W; Jung, R

    2017-12-01

    A neural interface system has been developed that consists of an implantable stimulator/recorder can with a 15-electrode lead that trifurcates into three bundles of five individual wire longitudinal intrafascicular electrodes. This work evaluated the mechanical fatigue resistance of the branched lead and distributed electrode system under conditions designed to mimic anticipated strain profiles that would be observed after implantation in the human upper arm. Custom test setups and procedures were developed to apply linear or angular strain at four critical stress riser points on the lead and electrode system. Each test was performed to evaluate fatigue under a high repetition/low amplitude paradigm designed to test the effects of arm movement on the leads during activities such as walking, or under a low repetition/high amplitude paradigm designed to test the effects of more strenuous upper arm activities. The tests were performed on representative samples of the implantable lead system for human use. The specimens were fabricated using procedures equivalent to those that will be used during production of human-use implants. Electrical and visual inspections of all test specimens were performed before and after the testing procedures to assess lead integrity. Measurements obtained before and after applying repetitive strain indicated that all test specimens retained electrical continuity and that electrical impedance remained well below pre-specified thresholds for detection of breakage. Visual inspection under a microscope at 10×  magnification did not reveal any signs of damage to the wires or silicone sheathing at the stress riser points. These results demonstrate that the branched lead of this implantable neural interface system has sufficient mechanical fatigue resistance to withstand strain profiles anticipated when the system is implanted in an arm. The novel test setups and paradigms may be useful in testing other lead systems.

  20. Mechanical fatigue resistance of an implantable branched lead system for a distributed set of longitudinal intrafascicular electrodes

    Science.gov (United States)

    Pena, A. E.; Kuntaegowdanahalli, S. S.; Abbas, J. J.; Patrick, J.; Horch, K. W.; Jung, R.

    2017-12-01

    Objective. A neural interface system has been developed that consists of an implantable stimulator/recorder can with a 15-electrode lead that trifurcates into three bundles of five individual wire longitudinal intrafascicular electrodes. This work evaluated the mechanical fatigue resistance of the branched lead and distributed electrode system under conditions designed to mimic anticipated strain profiles that would be observed after implantation in the human upper arm. Approach. Custom test setups and procedures were developed to apply linear or angular strain at four critical stress riser points on the lead and electrode system. Each test was performed to evaluate fatigue under a high repetition/low amplitude paradigm designed to test the effects of arm movement on the leads during activities such as walking, or under a low repetition/high amplitude paradigm designed to test the effects of more strenuous upper arm activities. The tests were performed on representative samples of the implantable lead system for human use. The specimens were fabricated using procedures equivalent to those that will be used during production of human-use implants. Electrical and visual inspections of all test specimens were performed before and after the testing procedures to assess lead integrity. Main results. Measurements obtained before and after applying repetitive strain indicated that all test specimens retained electrical continuity and that electrical impedance remained well below pre-specified thresholds for detection of breakage. Visual inspection under a microscope at 10×  magnification did not reveal any signs of damage to the wires or silicone sheathing at the stress riser points. Significance. These results demonstrate that the branched lead of this implantable neural interface system has sufficient mechanical fatigue resistance to withstand strain profiles anticipated when the system is implanted in an arm. The novel test setups and paradigms may be useful in

  1. Rhabdomyosarcoma associated with the lead wire of a pacemaker generator implant.

    Science.gov (United States)

    Thieman Mankin, Kelley M; Dunbar, Mark D; Toplon, David; Ginn, Pamela; Maisenbacher, Herbert W; Risselada, Marije

    2014-06-01

    An 11-year-old female spayed Labrador Retriever was presented for a draining, painful subcutaneous mass palpated over a previously implanted pacemaker generator. Infection was suspected and the mass was removed surgically. On cut surface, the mass was friable and mottled tan to brown with firm pale tan nodules, surrounding the pacemaker lead wire adjacent to the pacemaker generator. Cytologic interpretation of impression smears was consistent with a sarcoma, and suggestive of a rhabdomyosarcoma due to the presence of strap-like cells. On histopathologic examination, a highly invasive nodular mass surrounded the pacemaker lead, composed of pleomorphic round, spindle and strap cells, and multinucleated giant cells. The population exhibited microscopic invasion into the deep portion of the fibrous capsule surrounding the pacemaker generator. There were tumor emboli within small to medium subcutaneous veins adjacent to the mass. Immunohistochemically, the neoplastic cells stained positive for α-sarcomeric actin and vimentin, and negative for α-smooth muscle actin, consistent with a rhabdomyosarcoma arising at the site of the pacemaker generator. To our knowledge, this is the first report of a rhabdomyosarcoma associated with the lead wire of a pacemaker generator in a dog. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  2. Alternative right ventricular pacing sites.

    Science.gov (United States)

    Łuciuk, Dariusz; Łuciuk, Marek; Gajek, Jacek

    2015-01-01

    The main adverse effect of chronic stimulation is stimulation-induced heart failure in case of ventricular contraction dyssynchrony. Because of this fact, new techniques of stimulation should be considered to optimize electrotherapy. One of these methods is pacing from alternative right ventricular sites. The purpose of this article is to review currently accumulated data about alternative sites of cardiac pacing. Medline and PubMed bases were used to search English and Polish reports published recently. Recent studies report a deleterious effect of long term apical pacing. It is suggested that permanent apical stimulation, by omitting physiological conduction pattern with His-Purkinie network, may lead to electrical and mechanical dyssynchrony of heart muscle contraction. In the long term this pathological situation can lead to severe heart failure and death. Because of this, scientists began to search for some alternative sites of cardiac pacing to reduce the deleterious effect of stimulation. Based on current accumulated data, it is suggested that the right ventricular outflow tract, right ventricular septum, direct His-bundle or biventricular pacing are better alternatives due to more physiological electrical impulse propagation within the heart and the reduction of the dyssynchrony effect. These methods should preserve a better left ventricular function and prevent the development of heart failure in permanent paced patients. As there is still not enough, long-term, randomized, prospective, cross-over and multicenter studies, further research is required to validate the benefits of using this kind of therapy. The article should pay attention to new sites of cardiac stimulation as a better and safer method of treatment.

  3. The rationale and design of the Micra Transcatheter Pacing Study: safety and efficacy of a novel miniaturized pacemaker.

    Science.gov (United States)

    Ritter, Philippe; Duray, Gabor Z; Zhang, Shu; Narasimhan, Calambur; Soejima, Kyoko; Omar, Razali; Laager, Verla; Stromberg, Kurt; Williams, Eric; Reynolds, Dwight

    2015-05-01

    Recent advances in miniaturization technologies and battery chemistries have made it possible to develop a pacemaker small enough to implant within the heart while still aiming to provide similar battery longevity to conventional pacemakers. The Micra Transcatheter Pacing System is a miniaturized single-chamber pacemaker system that is delivered via catheter through the femoral vein. The pacemaker is implanted directly inside the right ventricle of the heart, eliminating the need for a device pocket and insertion of a pacing lead, thereby potentially avoiding some of the complications associated with traditional pacing systems. The Micra Transcatheter Pacing Study is currently undergoing evaluation in a prospective, multi-site, single-arm study. Approximately 720 patients will be implanted at up to 70 centres around the world. The study is designed to have a continuously growing body of evidence and data analyses are planned at various time points. The primary safety and efficacy objectives at 6-month post-implant are to demonstrate that (i) the percentage of Micra patients free from major complications related to the Micra system or implant procedure is significantly higher than 83% and (ii) the percentage of Micra patients with both low and stable thresholds is significantly higher than 80%. The safety performance benchmark is based on a reference dataset of 977 subjects from 6 recent pacemaker studies. The Micra Transcatheter Pacing Study will assess the safety and efficacy of a miniaturized, totally endocardial pacemaker in patients with an indication for implantation of a single-chamber ventricular pacemaker. NCT02004873. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. Pacing and Defibrillators in Complex Congenital Heart Disease

    Science.gov (United States)

    Chubb, Henry; O’Neill, Mark; Rosenthal, Eric

    2016-01-01

    Device therapy in the complex congenital heart disease (CHD) population is a challenging field. There is a myriad of devices available, but none designed specifically for the CHD patient group, and a scarcity of prospective studies to guide best practice. Baseline cardiac anatomy, prior surgical and interventional procedures, existing tachyarrhythmias and the requirement for future intervention all play a substantial role in decision making. For both pacing systems and implantable cardioverter defibrillators, numerous factors impact on the merits of system location (endovascular versus non-endovascular), lead positioning, device selection and device programming. For those with Fontan circulation and following the atrial switch procedure there are also very specific considerations regarding access and potential complications. This review discusses the published guidelines, device indications and the best available evidence for guidance of device implantation in the complex CHD population. PMID:27403295

  5. Spanish Pacemaker Registry. Twelfth Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2014).

    Science.gov (United States)

    Cano Pérez, Óscar; Pombo Jiménez, Marta; Coma Samartín, Raúl

    2015-12-01

    This report describes the results of the analysis of pacemaker implant and replacement data submitted to the Spanish Pacemaker Registry in 2014, with special reference to pacing mode selection. The report is based on the processing of information provided by the European Pacemaker Patient Identification Card. Information was received from 117 hospitals, with a total of 12 358 cards, representing 34% of estimated activity. Use of conventional generators and resynchronization devices was 784 and 64.4 units per million population, respectively. The mean age of patients receiving an implant was 77.3 years. Men received 59% of implants and 56.4% of replacements. Most patients receiving generator implants and replacements were in the age range 80 to 89 years. Most endocardial leads used were bipolar, and 84.2% had an active fixation system. Pacing was in VVI/R mode despite being in sinus rhythm in 24.7% of patients with sick sinus syndrome and 24% of those with atrioventricular block. The use of pacemaker generators and resynchronization devices per million population continued to increase. Most implanted leads had active fixation and approximately 20% had magnetic resonance imaging protection. Age and sex directly influenced pacing mode selection, which could have been improved in more than 20% of cases. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  6. Pacing-induced chronic atrial fibrillation impairs sinus node function in dogs. Electrophysiological remodeling.

    Science.gov (United States)

    Elvan, A; Wylie, K; Zipes, D P

    1996-12-01

    We assessed the effects of pacing-induced chronic atrial fibrillation (AF) on sinus node function, intra-atrial conduction, and atrial refractoriness. In 15 mongrel dogs (20 to 30 kg), AV nodal block was produced by radiofrequency catheter ablation, and a ventricular-inhibited (VVI) pacemaker (Minix 8330, Medtronic) was implanted and programmed to pace at 80 pulses per minute. In 11 of these dogs, right atrial endocardial pacing leads were connected to a pulse generator (Itrel 7432, Medtronic) and set at a rate of 20 Hz to induce AF. Corrected sinus node recovery time, P-wave duration, 24-hour Holter ECG to assess AF duration, maximal heart rate in response to isoproterenol (10 micrograms/min), intrinsic heart rate after administration of atropine (0.04 mg/kg) and propranolol (0.1 mg/kg), and atrial effective refractory periods (ERPs) were obtained at baseline (EPS-1) and after 2 to 6 weeks (EPS-2) of VVI pacing alone (n = 4) or VVI pacing and rapid atrial pacing (n = 11). At EPS-2, corrected sinus node recovery time and P-wave duration were prolonged, maximal heart rate and intrinsic heart rate were decreased, atrial ERPs were shortened, and the duration of AF was increased significantly compared with EPS-1. These changes partially reversed toward baseline 1 week after conversion to sinus rhythm. Sinus node function and AF inducibility observed in the control dogs that underwent ventricular pacing alone (n = 4) did not change. Pacing-induced chronic AF induces sinus node dysfunction, prolongs intra-atrial conduction time, shortens atrial refractoriness, and perpetuates AF, changes that reverse gradually after termination of AF.

  7. Impact of operator experience and training strategy on procedural outcomes with leadless pacing: Insights from the Micra Transcatheter Pacing Study.

    Science.gov (United States)

    El-Chami, Mikhael; Kowal, Robert C; Soejima, Kyoko; Ritter, Philippe; Duray, Gabor Z; Neuzil, Petr; Mont, Lluis; Kypta, Alexander; Sagi, Venkata; Hudnall, John Harrison; Stromberg, Kurt; Reynolds, Dwight

    2017-07-01

    Leadless pacemaker systems have been designed to avoid the need for a pocket and transvenous lead. However, delivery of this therapy requires a new catheter-based procedure. This study evaluates the role of operator experience and different training strategies on procedural outcomes. A total of 726 patients underwent implant attempt with the Micra transcatheter pacing system (TPS; Medtronic, Minneapolis, MN, USA) by 94 operators trained in a teaching laboratory using a simulator, cadaver, and large animal models (lab training) or locally at the hospital with simulator/demo model and proctorship (hospital training). Procedure success, procedure duration, fluoroscopy time, and safety outcomes were compared between training methods and experience (implant case number). The Micra TPS procedure was successful in 99.2% of attempts and did not differ between the 55 operators trained in the lab setting and the 39 operators trained locally at the hospital (P = 0.189). Implant case number was also not a determinant of procedural success (P = 0.456). Each operator performed between one and 55 procedures. Procedure time and fluoroscopy duration decreased by 2.0% (P = 0.002) and 3.2% (P safety outcomes by training method. Among a large group of operators, implantation success was high regardless of experience. While procedure duration and fluoroscopy times decreased with implant number, complications were low and not associated with case number. Procedure and safety outcomes were similar between distinct training methodologies. © 2017 Wiley Periodicals, Inc.

  8. Concept Design for a 1-Lead Wearable/Implantable ECG Front-End: Power Management.

    Science.gov (United States)

    George, Libin; Gargiulo, Gaetano Dario; Lehmann, Torsten; Hamilton, Tara Julia

    2015-11-19

    Power supply quality and stability are critical for wearable and implantable biomedical applications. For this reason we have designed a reconfigurable switched-capacitor DC-DC converter that, aside from having an extremely small footprint (with an active on-chip area of only 0.04 mm²), uses a novel output voltage control method based upon a combination of adaptive gain and discrete frequency scaling control schemes. This novel DC-DC converter achieves a measured output voltage range of 1.0 to 2.2 V with power delivery up to 7.5 mW with 75% efficiency. In this paper, we present the use of this converter as a power supply for a concept design of a wearable (15 mm × 15 mm) 1-lead ECG front-end sensor device that simultaneously harvests power and communicates with external receivers when exposed to a suitable RF field. Due to voltage range limitations of the fabrication process of the current prototype chip, we focus our analysis solely on the power supply of the ECG front-end whose design is also detailed in this paper. Measurement results show not just that the power supplied is regulated, clean and does not infringe upon the ECG bandwidth, but that there is negligible difference between signals acquired using standard linear power-supplies and when the power is regulated by our power management chip.

  9. Prevalence of venous obstruction in permanent endovenous pacing in newborns and infants: follow-up study.

    Science.gov (United States)

    Stojanov, Petar; Vranes, Mile; Velimirovic, Dusan; Zivkovic, Mirjana; Kocica, Mladen J; Davidovic, Lazar; Neskovic, Voislava; Stajevic, Mila

    2005-05-01

    We examined the prevalence of venous obstruction in 12 newborns and infants with permanent endovenous ventricular pacing, clinically, and by ultrasonographic assessment of hemodynamics (spontaneity, phasicity, velocity, and turbulence of flow) and morphologic parameters (compressibility, wall thickness, and thrombus presence). All implantations of single ventricular unipolar endovenous steroid leads, were performed via cephalic vein, and pacemakers were placed in subcutaneous pocket in right prepectoral region. After the vascular surgeon has carefully examined all children for presence of venous collaterals in the chest wall, morphologic and hemodynamic parameters of the subclavian, axillary, and internal jugular veins, were assessed by linear-array color Doppler. Lead capacity (LC) was calculated for each patient. Mean age of patients at implant was 6.2 months (range 1 day-12 months), mean weight 6.5 kg (range 2.25-10 kg), and mean height 60.9 cm (range 48-78 cm). Mean LC was 1.99 (range 1.14-3.07). Total follow-up was 1023 and mean follow-up 85.2 pacing months (range 3-156). No clinical signs of venous obstruction were observed. Mild stenosis (20%) of subclavian vein was found by color Doppler in 2/12 patients. Both had adequate lead diameter for body surface. Permanent endovenous pacing is a feasible procedure, even in children of body weight less than 10 kg, with quite acceptable impact on venous system patency.

  10. Financial audit of antitachycardia pacing for the control of recurrent supraventricular tachycardia.

    Science.gov (United States)

    Griffith, M J; Bexton, R S; McComb, J M

    1993-03-01

    To assess the financial implications of antitachycardia pacing in patients with frequent supraventricular tachycardia. Intertach pacemakers were implanted in 25 patients (mean age 47 years, five men): 22 had atrioventricular nodal reentry tachycardia. The patients had failed a mean of 4.9 (range zero to eight) drugs and had been admitted to hospital 3.7 (zero to 31) times over a symptomatic period of 13.9 years (two months to 54 years). The mean admission time for implantation was 2.8 (two to seven) days. One patient with Wolff-Parkinson-White syndrome subsequently underwent surgery. Infection occurred in two patients, and pain over the pacemaker required its resiting in two. Two patients have had one admission each for tachycardia. Six patients remain on anti-arrhythmic drugs. Costs were calculated including value added tax, capital charges, and allocated overheads. The cost a year before pacing was 1174 pounds including drug costs, clinic visits, and hospital admissions. The mean cost of pacemaker implantation was 3364.22 pounds, including the pacemaker and lead, admission and procedure, readmissions and first pacing check. Subsequent annual follow up cost was 73.72 pounds including annual clinic visits and drug costs. The cost of pacing is 4241 pounds whereas medical management costs 7044 pounds assuming pacemaker life of six years: with a 10 year life the cost is 4537 pounds compared with 11,740 pounds: with a 12 year life the cost is 4685 pounds compared with 14,088 pounds. The excess cost of implantation of an antitachycardia pacemaker is minimal in patients with frequent supraventricular tachycardia despite drug treatment and is justified by excellent control of symptoms and reduction of drug use and hospital admissions.

  11. RIght VErsus Left Apical transvenous pacing for bradycardia: Results of the RIVELA randomized study

    Directory of Open Access Journals (Sweden)

    Haran Burri

    2017-11-01

    Full Text Available Aims: To compare cardiac function when pacing from the right or left ventricular apex in patients with preserved left ventricular systolic function, at 1-year follow-up. Methods: Prospective, multicentre centre randomizing conventional right ventricular apical (RVA versus left ventricular apical (LVA pacing using a coronary sinus lead in patients requiring ventricular pacing for bradycardia. Follow-up was performed using 3D-echocardiography at 6 and 12 months. Results: A total of 36 patients (age 75.4 ± 8.7 years, 21 males were enrolled (17 patients in the RVA group and 19 patients in the LVA group. A right ventricular lead was implanted in 8 patients in the LVA group, mainly because of high capture thresholds. There were no differences in the primary endpoint of LVEF at 1 year (60.4 ± 7.1% vs 62.1 ± 7.2% for the RVA and LVA groups respectively, P = 0.26 nor in any of the secondary endpoints (left ventricular dimensions, left ventricular diastolic function, right ventricular systolic function and tricuspid/mitral insufficiency. LVEF did not change significantly over follow-up in either group. Capture thresholds were significantly higher in the LVA group, and two patients had unexpected loss of capture of the coronary sinus lead during follow-up. Conclusions: Left univentricular pacing seems to be comparable to conventional RVA pacing in terms of ventricular function at up to 1 year follow-up, and is an option to consider in selected patients (e.g. those with a tricuspid valve prosthesis. Keywords: Ventricular pacing, Right ventricle, Left ventricle, Coronary sinus, Ventricular function

  12. Impact of pacing modality and biventricular pacing on cardiac output and coronary conduit flow in the post-cardiotomy patient.

    LENUS (Irish Health Repository)

    Healy, David G

    2012-02-03

    We have previously demonstrated the role of univentricular pacing modalities in influencing coronary conduit flow in the immediate post-operative period in the cardiac surgery patient. We wanted to determine the mechanism of this improved coronary conduit and, in addition, to explore the possible benefits with biventricular pacing. Sixteen patients undergoing first time elective coronary artery bypass grafting who required pacing following surgery were recruited. Comparison of cardiac output and coronary conduit flow was performed between VVI and DDD pacing with a single right ventricular lead and biventricular pacing lead placement. Cardiac output was measured using arterial pulse waveform analysis while conduit flow was measured using ultrasonic transit time methodology. Cardiac output was greatest with DDD pacing using right ventricular lead placement only [DDD-univentricular 5.42 l (0.7), DDD-biventricular 5.33 l (0.8), VVI-univentricular 4.71 l (0.8), VVI-biventricular 4.68 l (0.6)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.023) and VVI-biventricular pacing (P=0.001) but there was no significant advantage to DDD-biventricular pacing (P=0.45). In relation to coronary conduit flow, DDD pacing again had the highest flow [DDD-univentricular 55 ml\\/min (24), DDD-biventricular 52 ml\\/min (25), VVI-univentricular 47 ml\\/min (23), VVI-biventricular 50 ml\\/min (26)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.006) pacing but not significantly different to VVI-biventricular pacing (P=0.109) or DDD-biventricular pacing (P=0.171). Pacing with a DDD modality offers the optimal coronary conduit flow by maximising cardiac output. Biventricular lead placement offered no significant benefit to coronary conduit flow or cardiac output.

  13. Spanish Pacemaker Registry. Thirteenth Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2015).

    Science.gov (United States)

    Pombo Jiménez, Marta; Cano Pérez, Óscar; Fidalgo Andrés, María Luisa; Lorente Carreño, Diego; Coma Samartín, Raúl

    2016-12-01

    We describe the results of the analysis of the devices implanted and conveyed to the Spanish Pacemaker Registry in 2015. The report is based on the processing of information provided by the European Pacemaker Patient Identification Card. We received information from 111 hospitals, with a total of 12 555 cards, representing 32.1% of all the estimated activity. The use of conventional generators and resynchronization devices was 820 and 73 units per million population, respectively. The mean age of the patients receiving an implantation was 77.7 years, and more than 50% of the devices were implanted in patients over 80 years of age. Overall, 58.6% of the implants and 58.8% of the replacements were performed in men. All of the endocardial leads employed were bipolar, 81.5% had an active fixation system, and 16.5% were compatible with magnetic resonance. Although dual chamber sequential pacing continues to be more widespread, pacing with VVI/R mode is used because up to 23.8% of the patients with sinus node disease are in sinus rhythm, as are 24.1% of those with atrioventricular block. The total use of pacemaker generators in Spain has increased by about 5% with respect to 2014. The majority of the leads implanted are of active fixation, and less than 20% are protected from magnetic resonance. The factors directly related to the selection of pacing mode are age and sex. In around 20% of patients, the choice of the pacing mode could be improved. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  14. Candida and cardiovascular implantable electronic devices: a case of lead and native aortic valve endocarditis and literature review.

    Science.gov (United States)

    Glavis-Bloom, Justin; Vasher, Scott; Marmor, Meghan; Fine, Antonella B; Chan, Philip A; Tashima, Karen T; Lonks, John R; Kojic, Erna M

    2015-11-01

    Use of cardiovascular implantable electronic devices (CIED), including permanent pacemakers (PPM) and implantable cardioverter defibrillators (ICD), has increased dramatically over the past two decades. Most CIED infections are caused by staphylococci. Fungal causes are rare and their prognosis is poor. To our knowledge, there has not been a previously reported case of multifocal Candida endocarditis involving both a native left-sided heart valve and a CIED lead. Here, we report the case of a 70-year-old patient who presented with nausea, vomiting, and generalised fatigue, and was found to have Candida glabrata endocarditis involving both a native aortic valve and right atrial ICD lead. We review the literature and summarise four additional cases of CIED-associated Candida endocarditis published from 2009 to 2014, updating a previously published review of cases prior to 2009. We additionally review treatment guidelines and discuss management of CIED-associated Candida endocarditis. © 2015 Blackwell Verlag GmbH.

  15. Temporary emergency pacing-an orphan in district hospitals

    DEFF Research Database (Denmark)

    Gjesdal, Knut; Johansen, Jens Brock; Gadler, Fredrik

    2012-01-01

    This editorial discusses a report on the 1 year experience with temporary pacing, especially in the emergency setting, in several Norwegian district hospitals. The vast majority of the patients received transvenous temporary pacing, and the majority of leads were placed by noncardiologists....... The procedure times were long and complications were frequent. The organization of emergency pacing is discussed, and we suggest that unless qualified physicians can establish transvenous pacing, the patients who need that should be transferred with transcutaneous pacing as back-up during transport...

  16. Indicators of a poor outcome after temporary pacing in patients with complete atrioventricular block

    International Nuclear Information System (INIS)

    Kazmi, U.; Hyder, S.N.; Sheikh, A.M.

    2013-01-01

    Background: Temporary pace maker (tpm) implantation is an emergency procedure, performed in symptomatic patients with AV block We report our experience of temporary pacing at a tertiary care center. It is the first study of its type from a local center. Objectives: To study the clinical course of patients after tpm implantation and to determine indicators of a poor outcome after tpm implantation. Methods: This was descriptive retrospective study. Data of all tpm procedures performed at Children Hospital from 2006 to 2012 was retrieved. We excluded patients with surgically placed tpm leads. All patients receiving transvenous tpm were included in our study. Results: Total of 12 patients received tpm, 8 were male (66.6%) and 4 were female (33.3%). Median age was 6 years ( range 1.4 -13 year ). Mean weight was 30kg, (range 8.7 - 50kg). All of them presented with complete heart block.One patient each had post diphtheria cardiomyopathy, unknown poisoning. The rest had congenital heart block. The mean period between tpm to ppm implantation was 5 days, (range 1 - 30 days). One patient spontaneously reverted to sinus rhythm(8.3%), 6 had ppm implantation (58.3%), 5 patients expired (33.3%). A low Ejection Fraction was found to be associated with a poor outcome (p<0.01). Variables that were associated with a poor outcome(mortality), were SOB (p<0.015), weak pulses (p<0.015), and hepatomegaly (p<0.01). Conclusion: Low Ejection Fraction and Heart failure is associated with a poor outcome and increased mortality in patients with complete AV block. We suggest that pacing should be considered in patients earlier, before they develop signs or symptoms of cardiac dysfunction. (author)

  17. Cardiac pacing in heart failure patients with left bundle branch block: impact of pacing site for optimizing left ventricular resynchronization.

    Science.gov (United States)

    Pappone, C; Rosanio, S; Oreto, G; Tocchi, M; Gulletta, S; Salvati, A; Dicandia, C; Santinelli, V; Mazzone, P; Veglia, F; Ding, J; Sallusti, L; Spinelli, J; Vicedomini, G

    2000-07-01

    Acute left ventricular pacing has been associated with hemodynamic improvement in patients with congestive heart failure and wide QRS complex. We hypothesized that pacing two left ventricular sites simultaneously would produce faster activation and better systolic function than single-site pacing. We selected 14 heart failure patients (NYHA functional class III or IV) in normal sinus rhythm with left bundle branch block and QRS > 150 ms. An 8F dual micromanometer catheter was placed in the aorta for measuring +dP/dt (mmHg/s), aortic pulse pressure (mmHg), and end-diastolic pressure (mmHg). Pacing leads were positioned via coronary veins at the posterior base and lateral wall. Patients were acutely paced VDD at the posterior base, lateral wall, and both sites (dual-site) with 5 atrioventricular delays (from 8 ms to PR -30 ms). Pacing sequences were executed in randomized order using a custom external computer (FlexStim, Guidant CRM). Dual-site pacing increased peak +dP/dt significantly more than posterior base and lateral wall pacing. Dual-site and posterior base pacing raised aortic pulse pressure significantly more than lateral wall pacing. Dual-site pacing shortened QRS duration by 22 %, whereas posterior base and lateral wall pacing increased it by 2 and 12%, respectively (p = 0.006). In heart failure patients with left bundle branch block, dual-site pacing improves systolic function more than single-site stimulation. Improved ventricular activation synchrony, expressed by paced QRS narrowing, may account for the additional benefit of dual- vs single-site pacing in enhancing contractility. This novel approach deserves consideration for future heart failure pacing studies.

  18. Pacing stress echocardiography

    Directory of Open Access Journals (Sweden)

    Agrusta Marco

    2005-12-01

    Full Text Available Abstract Background High-rate pacing is a valid stress test to be used in conjunction with echocardiography; it is independent of physical exercise and does not require drug administration. There are two main applications of pacing stress in the echo lab: the noninvasive detection of coronary artery disease through induction of a regional transient dysfunction; and the assessment of contractile reserve through peak systolic pressure/ end-systolic volume relationship at increasing heart rates to assess global left ventricular contractility. Methods The pathophysiologic rationale of pacing stress for noninvasive detection of coronary artery disease is obvious, with the stress determined by a controlled increase in heart rate, which is a major determinant of myocardial oxygen demand, and thereby tachycardia may exceed a fixed coronary flow reserve in the presence of hemodynamically significant coronary artery disease. The use of pacing stress echo to assess left ventricular contractile reserve is less established, but promising. Positive inotropic interventions are mirrored by smaller end-systolic volumes and higher end-systolic pressures. An increased heart rate progressively increases the force of ventricular contraction (Bowditch treppe or staircase phenomenon. To build the force-frequency relationship, the force is determined at different heart rate steps as the ratio of the systolic pressure (cuff sphygmomanometer/end-systolic volume index (biplane Simpson rule. The heart rate is determined from ECG. Conclusion Two-dimensional echocardiography during pacing is a useful tool in the detection of coronary artery disease. Because of its safety and ease of repeatability noninvasive pacing stress echo can be the first-line stress test in patients with permanent pacemaker. The force-frequency can be defined as up- sloping (normal when the peak stress pacing systolic pressure/end-systolic volume index is higher than baseline and intermediate stress

  19. PACE Status Update

    Energy Technology Data Exchange (ETDEWEB)

    M., Zimring,; Hoffman, I.; Fuller, M.

    2010-08-11

    The Federal Housing Finance Agency (FHFA) regulates Fannie Mae, Freddie Mac, and the 12 Federal Home Loan Banks (the government-sponsored enterprises - GSEs). On July 6, 2010, FHFA and the Office of the Comptroller of the Currency (OCC) concluded that Property Assessed Clean Energy (PACE) programs 'present significant safety and soundness concerns' to the housing finance industry. This statement came after a year of discussions with state and federal agencies in which PACE, a novel mechanism for financing energy efficiency and renewable energy improvements, has gone from receiving support from the White House, canonization as one of Scientific American's 'World Changing Ideas' and legislative adoption in 24 states to questionable relevance, at least in the residential sector. Whether PACE resumes its expansion as an innovative tool for financing energy efficiency and clean generation depends on outcomes in each of the three branches of government - discussions on a PACE pilot phase among federal agencies, litigation in federal court, and legislation in Congress - all highly uncertain. This policy brief addresses the practical impacts of these possible outcomes on existing and emerging PACE programs across the United States and potential paths forward.

  20. The influence of right ventricular apical pacing on left atrial volume in patients with normal left ventricular function

    Directory of Open Access Journals (Sweden)

    AR Moaref1

    2008-03-01

    Full Text Available Background: Right ventricular apical (RVA pacing has been reported to induce several deleterious effects particularly in the presence of structural heart disease but can also involve patients with normal left ventricular (LV function. Left atrial (LA enlargement is one of these effects, but the majority of studies have measured LA dimension rather than volume.Objective: The present prospective study was designed to assess the effect of RVA pacing on LA volume in patients with normal LV function.Patients and Methods: The study comprised 41 consecutive patients with LV ejection fraction ≥ 45% and LV end diastolic dimension ≤ 56 mm who underwent single-or dual- chamber pacemaker implantation in RVA and followed for LA volume measurement and pacemaker analysis at least during the ensuing 4.2 months. Results: In all, 21 patients were excluded from the study due to five spontaneous wide QRS complex (≥120msec, one recent acute coronary syndrome,one significant valvular heart disease, three pacing frequency <90%, eight death or losing follow up in three cases. In remaining 20 patients, LA volume ragned from 21 to 54 mm3 with mean of 37.3±9.7 mm3 prior to pacemaker implantation that increased to 31 to 103 mm3 (54.3±17.0 during follow-up (P<0.001.Conclusion: RVA pacing might lead to an increase in LA volume even in patients with normal LV function.

  1. The reduction of leading- and trailing-edge of high-voltage steep pulse in plasma immersion ion implantation

    International Nuclear Information System (INIS)

    Zhu Zongtao; Gui Gang; Wang Zhijian; Gong Chunzhi; Yang Shiqin; Tian Xiubo

    2010-01-01

    During plasma immersion ion implantation (PIII) processes, due to the capacitance effect of the coaxial cable and plasma load, the output voltage pulse of high-voltage modulator possesses a longer leading- and trailing-edge time. The leading- and trailing-edge of the high voltage (HV) pulse have a critical effect on the ion-energy uniformity, depth and dose distribution during PIII processes. In this work, a tetrode was used as a hard tube to switch the DC high voltage, and a HV pulse modulator with a maximum pulse voltage of 40 kV was built successfully. The effect of the trailing-edge time on the implantation uniformity was simulated by one-dimension PIC method. The potential on the control grids of the tetrode was optimized to obtain a HV pulse with a short rise time. In our system, 200 V potential on grid one is utilized and the leading-edge time of pulse can be as small as 1 μs. The IGBTs in series was utilized to release the remnant charges reserved in the equivalent capacitance of the plasma load and coaxial cable. Thus the trailing-edge time of the HV pulse could be reduced. The effect of the driver signals with different delay time and the absorption parameters of each IGBTs were simulated by PSPICE software to optimize the design the electric circuit. (authors)

  2. Internal Mammary Arterial Injury from Lead Extraction: A Clinically Subtle yet Important Complication of Implantable Device Removal

    Directory of Open Access Journals (Sweden)

    Cesar Cruz

    2011-01-01

    Full Text Available Percutaneous implantable device extraction has increased in recent years and is associated with small but significant risk. Arteriovenous fistula formation is an uncommon complication of this procedure. We report two cases where lead extraction was complicated by an arteriovenous fistula between the left internal mammary artery and the left brachiocephalic vein. In both cases, the patients were asymptomatic and the presence of a continuous murmur in the left subclavicular region led to the appropriate diagnosis. These were successfully treated with coil embolization. Auscultation around prior extraction sites should be routinely done to aid in the diagnosis of this potentially harmful complication.

  3. Lead Burden as a Factor for Higher Complication Rate in Patients With Implantable Cardiac Devices

    Directory of Open Access Journals (Sweden)

    Christopher Kolibash

    2015-01-01

    Full Text Available Purpose: Lead revisions have increased over the last decade. Patients who do not undergo lead extraction face an increased lead burden. Consequences of increased lead burden have not been fully defined. We sought to characterize the complication rate and outcomes in patients with sterile redundant leads. Methods: We retrospectively reviewed 242 consecutive patients [mean age 74 ± 12 years; 66.9% male] who underwent lead revision that resulted in an abandoned lead from January 2005 to June 2010. Patients were placed in a cohort based on number of leads after last recorded procedure (Group A: ≤2 [n=58]; Group B: 3-4 [n=168]; Group C: ≥5 [n=16]. Prespecified inhospital and long-term follow-up events were compared. Mortality rates were obtained from Social Security Death Index. Median follow-up was 2 years. Results: Baseline age, gender and race demographics were similar among the three groups. Increasing lead burden was associated with more adverse periprocedural events (A: 3.4%, B: 10.1%, C: 25.0%; P=0.031 and long-term device-related events (A: 1.7%, B: 13.0%, C: 18.8%; P=0.031. Device-related readmissions increased in frequency as lead burden increased (A: 3.5%, B: 18.5%, C: 37.5%; P=0.002. Combined periprocedural and late events also increased with more redundant leads (A: 5.2%, B: 23.2%, C: 44.0%; P=0.001. Total major events were infrequent (3.3%. There was no procedure-related mortality. Long-term all-cause mortality was not significantly different (A: 17.2%, B: 23.8%, C: 25.0%; P=0.567. Conclusions: Greater lead burden was associated with increased number of periprocedural and long-term minor events. It did not significantly impact major events or mortality.

  4. Recent developments in cardiac pacing.

    Science.gov (United States)

    Rodak, D J

    1995-10-01

    Indications for cardiac pacing continue to expand. Pacing to improve functional capacity, which is now common, relies on careful patient selection and technical improvements, such as complex software algorithms and diagnostic capabilities.

  5. Interaction between shock coils increased the incidence of inappropriate therapies and lead failure in implantable cardioverter defibrillator.

    Science.gov (United States)

    El Garhy, Mohammad; Ohlow, Marc-Alexander; Lauer, Bernward

    Shock coil interaction in patients with multiple implantable cardioverter defibrillator (ICD) leads is occasionally observed. We aimed to evaluate the incidence of shock coil interaction and its clinical relevance. All ICD patients (646 patients) who came to follow up control in our ICD ambulance between January 1, 2011, and December 31, 2011 in the department of cardiology in Bad Berka hospital were retrospectively evaluated in this study. All baseline demographic, clinical, and procedural characteristics and postoperative chest x ray in postero-anterior and lateral view as well as clinical and ICD follow up data were evaluated. Among 646 patients 42 had multiple ICD leads (6.5%) of whom 36 patients (5.5% of total cohort patients and 85.7% of patients with multiple ICD leads) had shock coil interaction and presented the study group (Group I). The control group (Group II) consisted of 610 patients without coil-coil interaction including patients with single shock lead (604 patients) or patients with multiple leads but without interaction between shock coils (6 patients). Inappropriate anti-tachycardia therapies and RV lead revisions were more frequent in patients with interaction between shock coils (Group I vs Group II: 27.7% and 5.7%; p = 0.049 and 30.6% vs 6.4; p = 0.0001, respectively). Interaction between shock coils may be one of possible causes of lead failure and resulted in inappropriate therapies and subsequent lead revision. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  6. Impaired expression of importin/karyopherin β1 leads to post-implantation lethality

    International Nuclear Information System (INIS)

    Miura, Katsutaka; Yoshinobu, Kumiko; Imaizumi, Takashi; Haruna, Kyoko; Miyamoto, Yoichi; Yoneda, Yoshihiro; Nakagata, Naomi; Araki, Masatake; Miyakawa, Taihei; Yamamura, Ken-ichi; Araki, Kimi

    2006-01-01

    Importin β1 (Impβ)/karyopherin β1 (Kpnb1) mediates the nuclear import of a large variety of substrates. This study aimed to investigate the requirement for the Kpnb1 gene in mouse development, using a gene trap line, B6-CB-Ayu8108 GtgeoIMEG (Ayu8108 geo ), in which the trap vector was inserted into the promoter region of the Kpnb1 gene, but in reverse orientation of the Kpnb1 gene. Ayu8108 geo/geo homozygous embryos could develop to the blastocyst stage, but died before embryonic day 5.5, and expression of the Kpnb1 gene in homozygous blastocysts was undetectable. We also replaced the βgeo gene with Impβ cDNA through Cre-mediated recombination to rescue Impβ expression. Homozygous mice for the rescued allele Ayu8108 Impβ/Impβ were born and developed normally. These results demonstrated that the cause of post-implantation lethality of Ayu8108 geo/geo homozygous embryos was impaired expression of the Kpnb1 gene, indicating indispensable roles of Impβ1 in early development of mice

  7. Transient ST-segment elevation in precordial leads by acute marginal branch occlusion during stent implantation.

    Science.gov (United States)

    Arzola, Leidimar Carballo; Esteban, Marcos T Rodríguez; Niebla, Javier García

    2016-01-01

    The isolated right ventricular infarction is a rare entity. Our case presented a selective occlusion of an acute marginal branch that supplies the right ventricular free wall with isolated ST elevation in precordial leads simulating an occlusion of the left anterior descending artery and without pseudonormalization in inferior due to the non-involvement of the main branch in the ischemic process. Our case clearly illustrates a rare differential diagnosis when a new ST segment elevation appears in earlier precordial leads in patients with symptoms of myocardial ischemia. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Estimation of the effects of multipoint pacing on battery longevity in routine clinical practice.

    Science.gov (United States)

    Akerström, Finn; Narváez, Irene; Puchol, Alberto; Pachón, Marta; Martín-Sierra, Cristina; Rodríguez-Mañero, Moisés; Rodríguez-Padial, Luis; Arias, Miguel A

    2017-09-23

    Multipoint pacing (MPP) permits simultaneous multisite pacing of the left ventricle (LV); initial studies suggest haemodynamic and clinical benefits over conventional (single LV site) cardiac resynchronization therapy (CRT). The aim of this study was to estimate the impact of MPP activation on battery longevity in routine clinical practice. Patient (n = 46) and device data were collected from two centres at least 3 months after MPP-CRT device implantation. Multipoint pacing programming was based on the maximal possible anatomical LV1/LV2 separation according to three predefined LV pacing capture threshold (PCT) cut-offs (≤1.5 V; ≤4.0 V; and ≤6.5 V). Estimated battery longevity was calculated using the programmed lower rate limit, lead impedances, outputs, and pacing percentages. Relative to the longevity for conventional CRT using the lowest PCT (8.9 ± 1.2 years), MPP activation significantly shortened battery longevity for all three PCT cut-offs (≤1.5 V, -5.6%; ≤4.0 V, -16.9%; ≤6.5 V, -21.3%; P's battery longevity was significantly shortened for the MPP ≤ 4.0 V and ≤6.5 V cut-offs (-10.8 and -15.7%, respectively; P's battery longevity compared with that for conventional CRT configuration. When reasonable MPP LV vector PCTs (≤4.0 V) are achieved, the decrease in battery longevity is relatively small which may prompt the clinician to activate MPP. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  9. Autocapture compatibility in patients with the MembraneEX lead and Affinity pulse generators.

    Science.gov (United States)

    Schuchert, A; Voitk, J; Liu, B; Kolk, R; Stammwitz, E; Beiras, J

    2001-10-01

    The first Autocapture generation worked well with all recommended leads. The newer Autocapture generation provides a more sensitive resolution for evoked response testing and its implementation in a dual-chamber device. The purpose of the study was to evaluate the performance of the Affinity SR/DR pacemaker with the new Autocapture algorithm in combination with the small surface area pacing lead MembraneEX in 129 patients. Autocapture ventricular threshold, sensing threshold, lead impedance, evoked response (ER) and polarization signals were determined at implantation and discharge, as well as after 1 and 3 months. Autocapture recommendation rate was based on the ER sensitivity test. The median pacing threshold was 0.38, 0.50, 0.75, 0.75 V at implant, discharge, 1 and 3 months post-implant, respectively. The respective data for median lead impedance were 744, 605, 649 and 691 ohms; median sensing threshold was 12.5 mV at all visits. The median ER amplitude was 9.0, 10.1, 9.9 and 10.1 mV and the median polarization signal 0.39 mV at all visits. The frequency of recommended Autocapture activation was 98.3%, 99.2%, 98.3% and 96.2% of all patients at implant, at discharge, 1 and 3 months post-implant respectively. In conclusion, the studied pulse generator enabled, in combination with this pacing lead, in >95% of all patients activation of Autocapture.

  10. Right ventricle/interventricular septum electrophysiological anatomy (determination of optimal right ventricular lead placement

    Directory of Open Access Journals (Sweden)

    М. В. Диденко

    2015-10-01

    Full Text Available Notwithstanding a theoretically justified lead placement into the interventricular septum (IVS, the data from the clinical trials demonstrate somewhat controversial results. One of these controversies is the absence of consolidated criteria for positioning the electrode to deliver pacing from the interventricular septum (IVS area. The study describes anatomic features of RV and IVS with respect to the cardiac conduction system, normal ventricular excitation and electrode implantation techniques for continuous pacing. A comparative study of 73 specimens of cadaver hearts was carried out by using electro-anatomic 3D mapping of the heart, X-ray examination, computer-aided tomography, morphological and morphometric investigation. It was found out that the medium part of IVS in the septomarginal trabecula zone could be considered the best for continuous pacing. The criteria for the RV lead to be implanted in this zone were determined.

  11. Osseointegration of Plateau Root Form Implants: Unique Healing Pathway Leading to Haversian-Like Long-Term Morphology.

    Science.gov (United States)

    Coelho, Paulo G; Suzuki, Marcelo; Marin, Charles; Granato, Rodrigo; Gil, Luis F; Tovar, Nick; Jimbo, Ryo; Neiva, Rodrigo; Bonfante, Estevam A

    2015-01-01

    Endosteal dental implants have been utilized as anchors for dental and orthopedic rehabilitations for decades with one of the highest treatment success rates in medicine. Such success is due to the phenomenon of osseointegration where after the implant surgical placement, bone healing results into an intimate contact between bone and implant surface. While osseointegration is an established phenomenon, the route which osseointegration occurs around endosteal implants is related to various implant design factors including surgical instrumentation and implant macro, micro, and nanometer scale geometry. In an implant system where void spaces (healing chambers) are present between the implant and bone immediately after placement, its inherent bone healing pathway results in unique opportunities to accelerate the osseointegration phenomenon at the short-term and its maintenance on the long-term through a haversian-like bone morphology and mechanical properties.

  12. [National Consultant in Cardiology Experts' Group Guidelines on dealing with patients implanted with some St. Jude Medical Riata and Riata ST leads].

    Science.gov (United States)

    Mitkowski, Przemysław; Grabowski, Marcin; Kowalski, Oskar; Kutarski, Andrzej; Mojkowski, Włodzimierz; Przybylski, Andrzej; Sterliński, Maciej; Trusz-Gluza, Maria; Opolski, Grzegorz

    2014-01-01

    In December 2010 St. Jude Medical informed about higher incidence of silicone insulation abrasion in implantable cardioverter-defibrillator leads Riata/Riata ST. The manifestation of this phenomenon is the externalisation of conductors outside the body of the lead, which is visible in a fluoroscopy. The abrasion could also involve an insulation under high-voltage coil and in the worst case could result in a short circuit within high voltage part of the system. The incidence of this phenomenon varies from part of to several dozen percent according to published papers and becomes higher in a longer follow-up. The highest probability of malfunction in 8 F single coil and the lowest in 7 F dual-coil leads is observed. For the needs of this guidelines all Riata/Riata ST leads were divided into: functioning, damaged but active (visible externalisation but electrically functioning), malfunctioning. In the last case the lead should be removed and a new one implanted (class of indication I) ,although only implantation of a new lead with abandoning malfunctioning one is allowed and should be considered (IIa). In patients with functioning lead extraction with a new lead implantation may be considered during elective replacement only in high risk patients (IIb). In case of damaged but active lead its extraction with the implantation of a new lead during elective replacement of the device should be considered in high risk population (IIa) and may be considered in other patients (IIb). The final decision related to Riata/Riata ST should be individualised and undertaken in co-operation with the patient after detailed assessment of the risk related to each treatment option.

  13. Effect of steroid eluting versus conventional electrodes on propafenone induced rise in chronic ventricular pacing threshold.

    Science.gov (United States)

    Cornacchia, D; Fabbri, M; Maresta, A; Nigro, P; Sorrentino, F; Puglisi, A; Ricci, R; Peraldo, C; Fazzari, M; Pistis, G

    1993-12-01

    The aim of this study was to evaluate chronic ventricular pacing threshold increase after oral propafenone therapy. Eighty-three patients affected by advanced atrioventricular block and sick sinus syndrome were studied at least 3 months after pacemaker implantation, before and after oral propafenone therapy (450-900 mg/day based on body weight). The patients were subdivided into three groups according to the type of unipolar electrode that was implanted: group I (41 patients) Medtronic CapSure 4003, group II (30 patients) Medtronic Target Tip 4011, and group III (12 patients) Osypka Vy screw-in lead. In all cases a Medtronic unipolar pacemaker was implanted: 30 Minix, 23 Activitrax, 14 Elite, 12 Legend, and 4 Pasys. Propafenone blood level was measured in 75 patients 3-5 hours after propafenone administration. The pacing autothreshold was measured at 0.8 V, 1.6 V, and 2.5 V by reducing pulse width. At the three different outputs before and after propafenone, threshold increments were significantly lower in group I in comparison with group II and group III (propafenone ranging from < 0.001 to < 0.05). No significant difference was found in pacing impedance or in propafenone plasma concentration in the three groups. Strength-duration curves were drawn for each group at baseline and after propafenone administration. Before propafenone, in group I, the knee was markedly shifted to the left and downward as compared to the classic curve, so that the steep part was predominant; in group II and group III this shift was progressively less evident.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Pacemakers and implantable cardioverter defibrillators - general and anesthetic considerations

    Directory of Open Access Journals (Sweden)

    Amy G. Rapsang

    2014-06-01

    Full Text Available A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia, special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary.

  15. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto [University Federico II, Department of Biomorphological and Functional Sciences, Institute of Biostructure and Bioimages of the National Council of Research, Naples (Italy); Duilio, Carlo; Santomauro, Maurizio [University Federico II, Department of Clinical Medicine, Cardiovascular and Immunological Sciences, Naples (Italy)

    2005-09-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction {>=}50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  16. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    International Nuclear Information System (INIS)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto; Duilio, Carlo; Santomauro, Maurizio

    2005-01-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction ≥50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  17. Timing of Conduction Abnormalities Leading to Permanent Pacemaker Insertion After Transcatheter Aortic Valve Implantation-A Single-Centre Review.

    Science.gov (United States)

    Ozier, Daniel; Zivkovic, Nevena; Elbaz-Greener, Gabby; Singh, Sheldon M; Wijeysundera, Harindra C

    2017-12-01

    Transcatheter aortic valve implantation (TAVI) is the preferred alternative to traditional surgical aortic valve replacement; however, it remains expensive. One potential driver of cost is the need for postprocedural monitoring for conduction abnormalities after TAVI. Given the paucity of literature on the optimal length of monitoring, we aimed to determine when clinically significant conduction abnormalities leading to permanent pacemaker (PPM) insertion after TAVI were first identified. We identified all patients in the Sunnybrook Health Sciences Centre TAVI registry (Toronto, Canada) who underwent TAVI between 2009 and 2016, excluding those with pre-existing PPMs or those who underwent emergency open heart surgery. Through dedicated chart review, the timing and type of conduction abnormalities leading to PPM were recorded. Patients were divided according to the timing of conduction abnormality: during the procedure vs after the procedure. The overall PPM insertion rate was 15.6% (80 of 512 cases), with all but 1 patient receiving a PPM for class I indications. PPMs were inserted for complete heart block/high-grade atrioventricular block (91.3%), severe sinus node dysfunction (3.8%), and alternating bundle branch block (3.8%). Of these conduction abnormalities, 55.0% occurred during the procedure (intraprocedure; n = 44 patients). The mean time to the development of a conduction abnormality necessitating PPM was 1.2 days (interquartile range, 0-2 days), with 88.8% occurring within 72 hours of the procedure (n = 71 patients). In the entire TAVI cohort, leading to PPM. The majority of conduction abnormalities leading to PPM insertion after TAVI occur in the very early periprocedural period, suggesting that early mobilization and discharge will be safe from a conduction standpoint. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  18. Medial subclavicular musculotendinous complex and insulation break: Rare cause of late pacemaker lead malfunction

    Directory of Open Access Journals (Sweden)

    Pranab Jyoti Bhattacharyya

    2015-12-01

    Full Text Available Insulation break in a permanent pacemaker lead is a rare long-term complication. We describe an elderly male with a VVIR pacemaker, who presented with an episode of presyncope more than 3 years after the initial implantation procedure, attributed to insulation break possibly caused by lead entrapment in components of the medial subclavicular musculotendinous complex (MSMC and repeated compressive damage over time during ipsilateral arm movement requiring lead replacement. The differential diagnosis of a clinical presentation when pacing stimuli are present with failure to capture and the role of the MSMC in causing lead damage late after implantation are discussed.

  19. Selection of permanent pacing position of cardiac ventricle in patients with complete right bundle branch block

    International Nuclear Information System (INIS)

    Yang Minquan; Zhou Jun; Zhu Yan; Wang Jin; Rong Xin; Zhang Xiaoyi

    2005-01-01

    Objective: To find out the optimal pacing localization by comparing different pacing positions of the right ventricle in brady-cardiacarrhythmia patients with complete right bundle branch block. Methods: DDD type of double lumen permanent pacemaker was implanted in each of the 8 cases of sick sinus syndrome (SSS) and/or III degree atrioventricular block (III degree AVB) with complete right bundle branch block in normal heart function or class I. For each patient, four pacing positions in right ventricle were compared and the QRS pacing durations were recorded. The position with the shortest the QRS duration was chosen as the permanent pacing position. Heart function, chest X-rays and left ventricle ejection fraction (LVEF) were followed up after the operation. Results: In all the 8 cases, the posterior septum of the right ventricle were chosen as the permanent pacing position, with the shorter pacing QRS duration than that of pre-operation (P<0.05) and other pacing positions of the right ventricle. All parameters of this permanent pacing position were within the normal range. During the follow-up of 6-36 months, no abnormity was found in cardiac functions. Conclusion: In brady-cardiacarrhythmia patients with complete right bundle branch block, the implantation of permanent pacemaker should be at the junction region of inlet and outlet tracts, of the posterior septum of the right ventricle with ideal physiological function. (authors)

  20. Improvement of Left Ventricular Function by Permanent Direct His-Bundle Pacing in a Case with Dilated Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Yukiko Sashida, MD

    2006-01-01

    Full Text Available The patient was a 67-year-old female diagnosed with dilated cardiomyopathy. She had chronic atrial fibrillation (AF with bradycardia and low left ventricular function (left ventricular ejection fraction (LVEF 40%. She was admitted for congestive heart failure. She remained New York Heart Association (NYHA functional class III due to AF bradycardia. Pacemaker implantation was necessary for treatment of heart failure and administration of dose intensive β-blockers. As she had normal His-Purkinje activation, we examined the optimal pacing sites. Hemodynamics of His-bundle pacing and biventricular pacing were compared. Pulmonary capillary wedge pressure (PCWP was significantly lower on Hisbundle pacing than right ventricular (RV apical pacing and biventricular pacing (13mmHg, 19mmHg, and 19mmHg, respectively with an almost equal cardiac index. Based on the examination we implanted a permanent pacemaker for Direct His-bundle pacing (DHBP. After the DHBP implantation, the LVEF immediately improved from 40% to 55%, and BNP level decreased from 422 pg/ml to 42 pg/ml. The number of premature ventricular complex (PVC was decreased, and non sustained ventricular tachycardia (NSVT disappeared. Pacing threshold for His-bundle pacing has remained at the same level. His-bundle pacing has been maintained during 27 months and her long-term DHBP can improve cardiac function and the NYHA functional class.

  1. [TRENDS OF PERMANENT PACEMAKER IMPLANTATION IN A SINGLE CENTER OVER A 20-YEAR PERIOD].

    Science.gov (United States)

    Antonelli, Dante; Ilan, Limor Bushar; Freedberg, Nahum A; Feldman, Alexander; Turgeman, Yoav

    2015-05-01

    To review the changes in permanent pacemaker implantation indications, pacing modes and patients' demographics over a 20-year period. We retrospectively retrieved data on patients who underwent first implantation of the pacemaker between 1-1-1991 and 31-12-2010. One thousand and nine (1,009) patients underwent a first pacemaker implantation during that period; 535 were men (53%), their mean age was 74.6±19.5 years; the highest rate of implanted pacemaker was in patients ranging in age from 70-79 years, however there was an increasing number of patients aged over 80 years. The median survival time after initial pacemaker implantation was 8 years. Syncope was the most common symptom (62.5%) and atrioventricular block was the most common electrocardiographic indication (56.4%) leading to pacemaker implantation. There was increased utilization of dual chamber and rate responsive pacemakers over the years. There was no difference regarding mode selection between genders. Pacemaker implantation rates have increased over a 20-year period. Dual chamber replaced most of the single ventricular chamber pacemaker and rate responsive pacemakers became the norm. The data of a small volume center are similar to those reported in pacemaker surveys of high volume pacemaker implantation centers. They confirm adherence to the published guidelines for pacing.

  2. Ventilação elétrica: indicações e aspectos técnicos do implante cirúrgico do marca-passo de estimulação diafragmática Electric ventilation: indications for and technical aspects of diaphragm pacing stimulation surgical implantation

    Directory of Open Access Journals (Sweden)

    Miguel Lia Tedde

    2012-10-01

    Full Text Available OBJETIVO: Pacientes com lesão medular cervical alta em geral são dependentes de ventilação mecânica, que, embora salve vidas, está associada a complicações e redução da expectativa de vida devido a infecções respiratórias. A estimulação do diafragma por marca-passo, às vezes chamada de ventilação elétrica, induz a inspiração por estimulação dos músculos inspiratórios. Nosso objetivo foi destacar as indicações e alguns aspectos da técnica cirúrgica empregada no implante laparoscópico dos eletrodos, assim como descrever cinco casos de pacientes tetraplégicos submetidos à técnica. MÉTODOS: A seleção dos pacientes envolveu estudos de condução do nervo frênico por via transcutânea para determinar se os nervos estavam preservados. A abordagem cirúrgica foi laparoscopia clássica, com quatro trocartes. A técnica foi iniciada com o mapeamento elétrico para encontrar os "pontos motores" (pontos de contração máxima do diafragma. Se o mapeamento era bem-sucedido, dois eletrodos eram implantados na face abdominal de cada lado do diafragma para estimular ramos do nervo frênico. RESULTADOS: Dos cinco pacientes, três e um, respectivamente, eram capazes de respirar somente com o uso do marca-passo por períodos superiores a 24 e 6 h, enquanto um não era capaz. CONCLUSÕES: Embora seja necessário um acompanhamento mais longo para chegar a conclusões definitivas, os resultados iniciais são promissores, pois, no momento, a maioria dos nossos pacientes pode permanecer sem ventilação mecânica por longos períodos de tempo.OBJECTIVE: Patients with high cervical spinal cord injury are usually dependent on mechanical ventilation support, which, albeit life saving, is associated with complications and decreased life expectancy because of respiratory infections. Diaphragm pacing stimulation (DPS, sometimes referred to as electric ventilation, induces inhalation by stimulating the inspiratory muscles. Our objective

  3. Late deterioration of left ventricular function after right ventricular pacemaker implantation.

    Science.gov (United States)

    Bellmann, Barbara; Muntean, Bogdan G; Lin, Tina; Gemein, Christopher; Schmitz, Kathrin; Schauerte, Patrick

    2016-09-01

    Right ventricular (RV) pacing induces a left bundle branch block pattern on ECG and may promote heart failure. Patients with dual chamber pacemakers (DCPs) who present with progressive reduction in left ventricular ejection fraction (LVEF) secondary to RV pacing are candidates for cardiac resynchronization therapy (CRT). This study analyzes whether upgrading DCP to CRT with the additional implantation of a left ventricular (LV) lead improves LV function in patients with reduced LVEF following DCP implantation. Twenty-two patients (13 males) implanted with DCPs and a high RV pacing percentage (>90%) were evaluated in term of new-onset heart failure symptoms. The patients were enrolled in this retrospective single-center study after obvious causes for a reduced LVEF were excluded with echocardiography and coronary angiography. In all patients, DCPs were then upgraded to biventricular devices. LVEF was analyzed with a two-sided t-test. QRS duration and brain natriuretic peptide (BNP) levels were analyzed with the unpaired t-test. LVEF declined after DCP implantation from 54±10% to 31±7%, and the mean QRS duration was 161±20 ms during RV pacing. NT-pro BNP levels were elevated (3365±11436 pmol/L). After upgrading to a biventricular device, a biventricular pacing percentage of 98.1±2% was achieved. QRS duration decreased to 108±16 ms and 106±20 ms after 1 and 6 months, respectively. There was a significant increase in LVEF to 38±8% and 41±11% and a decrease in NT-pro BNP levels to 3088±2326 pmol/L and 1860±1838 pmol/L at 1 and 6 months, respectively. Upgrading to CRT may be beneficial in patients with DCPs and heart failure induced by a high RV pacing percentage.

  4. Optimal implantation depth and adherence to guidelines on permanent pacing to improve the results of transcatheter aortic valve replacement with the medtronic corevalve system: The CoreValve prospective, international, post-market ADVANCE-II study

    NARCIS (Netherlands)

    A.S. Petronio (Anna); J.-M. Sinning (Jan-Malte); N.M. van Mieghem (Nicolas); G. Zucchelli (Giulio); G. Nickenig (Georg); R. Bekeredjian (Raffi); J. Bosmans (Johan); F. Bedogni (Francesco); M. Branny (Marian); K. Stangl (Karl); J. Kovac (Jan); M. Schiltgen (Molly); S. Kraus (Stacia); P.P.T. de Jaegere (Peter)

    2015-01-01

    textabstractObjectives The aim of the CoreValve prospective, international, post-market ADVANCE-II study was to define the rates of conduction disturbances and permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement with the Medtronic CoreValve System (Minneapolis,

  5. Early Ahmed glaucoma valve implantation after penetrating keratoplasty leads to better outcomes in an Asian population with preexisting glaucoma.

    Directory of Open Access Journals (Sweden)

    Ming-Cheng Tai

    Full Text Available BACKGROUND: To evaluate the efficacy of Ahmed Glaucoma Valve (AGV surgery and the optimal interval between penetrating keratoplasty (PKP and AGV implantation in a population of Asian patients with preexisting glaucoma who underwent PKP. METHODOLOGY/PRINCIPAL FINDINGS: In total, 45 eyes of 45 patients were included in this retrospective chart review. The final intraocular pressures (IOPs, graft survival rate, and changes in visual acuity were assessed to evaluate the outcomes of AGV implantations in eyes in which AGV implantation occurred within 1 month of post-PKP IOP elevation (Group 1 and in eyes in which AGV implantation took place more than 1 month after the post-PKP IOP evaluation (Group 2. Factors that were associated with graft failure were analyzed, and the overall patterns of complications were reviewed. By their final follow-up visits, 58% of the patients had been successfully treated for glaucoma. After the operation, there were no statistically significant differences between the groups with respect to graft survival (p = 0.98, but significant differences for IOP control (p = 0.049 and the maintenance of visual acuity (VA (p21 mm Hg. The most common surgical complication, aside from graft failure, was hyphema. CONCLUSIONS/SIGNIFICANCE: Early AGV implantation results in a higher probability of AGV survival and a better VA outcome without increasing the risk of corneal graft failure as a result of post-PKP glaucoma drainage tube implantation.

  6. Early Ahmed Glaucoma Valve Implantation after Penetrating Keratoplasty Leads to Better Outcomes in an Asian Population with Preexisting Glaucoma

    Science.gov (United States)

    Tai, Ming-Cheng; Chen, Yi-Hao; Cheng, Jen-Hao; Liang, Chang-Min; Chen, Jiann-Torng; Chen, Ching-Long; Lu, Da-Wen

    2012-01-01

    Background To evaluate the efficacy of Ahmed Glaucoma Valve (AGV) surgery and the optimal interval between penetrating keratoplasty (PKP) and AGV implantation in a population of Asian patients with preexisting glaucoma who underwent PKP. Methodology/Principal Findings In total, 45 eyes of 45 patients were included in this retrospective chart review. The final intraocular pressures (IOPs), graft survival rate, and changes in visual acuity were assessed to evaluate the outcomes of AGV implantations in eyes in which AGV implantation occurred within 1 month of post-PKP IOP elevation (Group 1) and in eyes in which AGV implantation took place more than 1 month after the post-PKP IOP evaluation (Group 2). Factors that were associated with graft failure were analyzed, and the overall patterns of complications were reviewed. By their final follow-up visits, 58% of the patients had been successfully treated for glaucoma. After the operation, there were no statistically significant differences between the groups with respect to graft survival (p = 0.98), but significant differences for IOP control (p = 0.049) and the maintenance of visual acuity (VA) (pglaucoma, a history of previous PKP, and a preoperative IOP that was >21 mm Hg. The most common surgical complication, aside from graft failure, was hyphema. Conclusions/Significance Early AGV implantation results in a higher probability of AGV survival and a better VA outcome without increasing the risk of corneal graft failure as a result of post-PKP glaucoma drainage tube implantation. PMID:22629464

  7. Managed ventricular pacing vs. conventional dual-chamber pacing for elective replacements: the PreFER MVP study: clinical background, rationale, and design.

    Science.gov (United States)

    Quesada, Aurelio; Botto, Gianluca; Erdogan, Ali; Kozak, Milan; Lercher, Peter; Nielsen, Jens Cosedis; Piot, Olivier; Ricci, Renato; Weiss, Christian; Becker, Daniel; Wetzels, Gwenn; De Roy, Luc

    2008-03-01

    Several clinical studies have shown that, in patients with intact atrioventricular (AV) conduction, unnecessary chronic right ventricular (RV) pacing can be detrimental. The managed ventricular pacing (MVP) algorithm is designed to give preference to spontaneous AV conduction, thus minimizing RV pacing. The clinical outcomes of MVP are being studied in several ongoing trials in patients undergoing a first device implantation, but it is unknown to what extent MVP is beneficial in patients with a history of ventricular pacing. The purpose of the Prefer for Elective Replacement MVP (PreFER MVP) study is to assess the superiority of the MVP algorithm to conventional pacemaker and implantable cardioverter-defibrillator programming in terms of freedom from hospitalization for cardiovascular causes in a population of patients exposed to long periods of ventricular pacing. PreFER MVP is a prospective, 1:1 parallel, randomized (MVP ON/MVP OFF), single-blinded multi-centre trial. The study population consists of patients with more than 40% ventricular pacing documented with their previous device. Approximately, 600 patients will be randomized and followed for at least 24 months. The primary endpoint comprises cardiovascular hospitalization. The PreFER MVP trial is the first large prospective randomized clinical trial evaluating the effect of MVP in patients with a history of RV pacing.

  8. Successful pacing using a batteryless sunlight-powered pacemaker.

    Science.gov (United States)

    Haeberlin, Andreas; Zurbuchen, Adrian; Schaerer, Jakob; Wagner, Joerg; Walpen, Sébastien; Huber, Christoph; Haeberlin, Heinrich; Fuhrer, Juerg; Vogel, Rolf

    2014-10-01

    Today's cardiac pacemakers are powered by batteries with limited energy capacity. As the battery's lifetime ends, the pacemaker needs to be replaced. This surgical re-intervention is costly and bears the risk of complications. Thus, a pacemaker without primary batteries is desirable. The goal of this study was to test whether transcutaneous solar light could power a pacemaker. We used a three-step approach to investigate the feasibility of sunlight-powered cardiac pacing. First, the harvestable power was estimated. Theoretically, a subcutaneously implanted 1 cm(2) solar module may harvest ∼2500 µW from sunlight (3 mm implantation depth). Secondly, ex vivo measurements were performed with solar cells placed under pig skin flaps exposed to a solar simulator and real sunlight. Ex vivo measurements under real sunlight resulted in a median output power of 4941 µW/cm(2) [interquartile range (IQR) 3767-5598 µW/cm(2), median skin flap thickness 3.0 mm (IQR 2.7-3.3 mm)]. The output power strongly depended on implantation depth (ρSpearman = -0.86, P pacemaker powered by a 3.24 cm(2) solar module was implanted in vivo in a pig to measure output power and to pace. In vivo measurements showed a median output power of >3500 µW/cm(2) (skin flap thickness 2.8-3.84 mm). Successful batteryless VVI pacing using a subcutaneously implanted solar module was performed. Based on our results, we estimate that a few minutes of direct sunlight (irradiating an implanted solar module) allow powering a pacemaker for 24 h using a suitable energy storage. Thus, powering a pacemaker by sunlight is feasible and may be an alternative energy supply for tomorrow's pacemakers. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  9. Phrenic pacing compared with mechanical ventilation

    DEFF Research Database (Denmark)

    Andersen, Morten Packert; Laub, Michael; Biering-Sørensen, Fin

    2017-01-01

    mechanical ventilator dependent tetraplegics met the inclusion criteria. Data were retrieved from medical records and a structured follow-up interview with seven individuals from each group. RESULTS: No significant differences were found when comparing age at injury, time since injury, length...... of hospitalization, incidence of pneumonia, number of pneumonia hospitalizations, number of tracheal suctions, speech quality and activities of daily living or quality of life. On the Short Form Health Survey (SF36) mental health summary the median for both users of phrenic nerve pacing and users of mechanical...... ventilation was one s.d. above the mean of a standard population. CONCLUSIONS: Nine people have had a phrenic nerve pacer implanted. They do not significantly differ from a group of home mechanical ventilator dependent tetraplegics on a number of performance measures, but both groups seem to have better...

  10. Optogenetic pacing in Drosophila melanogaster

    Science.gov (United States)

    Alex, Aneesh; Li, Airong; Tanzi, Rudolph E.; Zhou, Chao

    2015-01-01

    Electrical stimulation is currently the gold standard for cardiac pacing. However, it is invasive and nonspecific for cardiac tissues. We recently developed a noninvasive cardiac pacing technique using optogenetic tools, which are widely used in neuroscience. Optogenetic pacing of the heart provides high spatial and temporal precisions, is specific for cardiac tissues, avoids artifacts associated with electrical stimulation, and therefore promises to be a powerful tool in basic cardiac research. We demonstrated optogenetic control of heart rhythm in a well-established model organism, Drosophila melanogaster. We developed transgenic flies expressing a light-gated cation channel, channelrhodopsin-2 (ChR2), specifically in their hearts and demonstrated successful optogenetic pacing of ChR2-expressing Drosophila at different developmental stages, including the larva, pupa, and adult stages. A high-speed and ultrahigh-resolution optical coherence microscopy imaging system that is capable of providing images at a rate of 130 frames/s with axial and transverse resolutions of 1.5 and 3.9 μm, respectively, was used to noninvasively monitor Drosophila cardiac function and its response to pacing stimulation. The development of a noninvasive integrated optical pacing and imaging system provides a novel platform for performing research studies in developmental cardiology. PMID:26601299

  11. Tapered, Double-Lead Threads Single Implants Placed in Fresh Extraction Sockets and Healed Sites of the Posterior Jaws: A Multicenter Randomized Controlled Trial with 1 to 3 Years of Follow-Up.

    Science.gov (United States)

    Cucchi, Alessandro; Vignudelli, Elisabetta; Franco, Simonetta; Levrini, Luca; Castellani, Dario; Pagliani, Luca; Rea, Massimiliano; Modena, Claudio; Sandri, Giulio; Longhi, Carlo

    2017-01-01

    To evaluate the survival, success, and complication rates of tapered double-lead threads single implants, placed in fresh extraction sockets and healed sites of the posterior jaws. The enrolled patients were randomly divided into 2 groups: in the test group (TG), all implants were inserted at the time of tooth extraction; in the control group (CG), all implants were placed 3 months after extraction. The implants were followed for a period of 1 to 3 years after loading. The main outcomes were implant survival, complications, and implant-crown success. Ninety-two patients had 97 installed implants (49 in the TG, 48 in the CG). Only two implants failed, in the TG; the survival rates were therefore 95.9% (47/49) and 100% (48/48) for TG and CG, respectively. In the surviving implants, no complications were reported, for an implant-crown success of 100%. Although a significant difference was found in the levels of primary stability between TG and CG, single implants placed in fresh extraction sockets and healed sites of the posterior jaws had similar survival and complication rates. Crestal bone levels and peri-implant bone resorption showed similar values. A longer follow-up period is however required, to confirm these positive outcomes.

  12. Reconstruction of the Terminal of an Abandoned Fractured Unipolar Coronary Sinus Lead: a Feasible Solution to Restore Effective Cardiac Resynchronization Therapy

    Directory of Open Access Journals (Sweden)

    Armando Gardini, MD

    2013-05-01

    Full Text Available Complications related to coronary sinus lead are not infrequent in recipients of cardiac resynchronization devices. We describe the case of a patient with a biventricular implantable cardioverter defibrillator with persistent phrenic nerve stimulation, previous coronary sinus lead fracture, and severe left subclavian vein stenosis. The reimplantation of a new coronary sinus lead on the left side, ipsilateral to the original implant, was unsuccessful. In order to avoid more complex and risky procedures, we performed the repair of the fractured abandoned lead with the reconstruction of the unipolar lead terminal. Effective biventricular pacing was obtained with satisfactory electrical parameters and it was maintained at twelve months follow-up.

  13. Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation.

    Science.gov (United States)

    Chang, James D; Manning, Warren J; Ebrille, Elisa; Zimetbaum, Peter J

    2017-05-09

    The potential for cardiac implantable electronic device leads to interfere with tricuspid valve (TV) function has gained increasing recognition as having hemodynamic and clinical consequences associated with incremental morbidity and death. The diagnosis and treatment of lead-related (as distinct from functional) tricuspid regurgitation pose unique challenges. Because of pitfalls in routine diagnostic imaging, a high level of clinical suspicion must be maintained to avoid overlooking the possibility that worsening heart failure is a consequence of mechanical interference with TV leaflet mobility or coaptation and is amenable to lead extraction or valve repair or replacement. The future of cardiac implantable electronic devices includes pacing and perhaps defibrillation without a lead traversing the TV. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Right ventricular pacemaker lead position is associated with differences in long-term outcomes and complications.

    Science.gov (United States)

    Witt, Chance M; Lenz, Charles J; Shih, Henry H; Ebrille, Elisa; Rosenbaum, Andrew N; van Zyl, Martin; Aung, Htin; Manocha, Kevin K; Deshmukh, Abhishek J; Hodge, David O; Mulpuru, Siva K; Cha, Yong-Mei; Espinosa, Raul E; Asirvatham, Samuel J; Mcleod, Christopher J

    2017-08-01

    Cardiac pacing from the right ventricular apex is associated with detrimental long-term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long-term outcomes and lead-related complications associated with differing ventricular lead tip position. All adult patients who underwent dual-chamber pacemaker implantation from 2004 to 2014 were included if they had postprocedure chest radiographs amenable to lead position determination. Long-term outcomes and lead-related complication rates were recorded. These were compared at 5 years between: (1) apical and septal leads, (2) apical and nonseptal nonapical (NSNA), and (3) apical and septal with >40% ventricular pacing. We retrospectively evaluated 3,450 patients, which included 238 with a septal position and 733 with NSNA lead positions. Septal lead position was associated with a lower mortality compared to apical leads (24% vs. 31%, P = 0.02). In patients with greater than 40% pacing, septal leads were associated with significantly higher rates of incident atrial fibrillation compared to apical leads (49% vs. 34%, P = 0.04). NSNA positions were associated with a significantly higher rate of lead dislodgement (4% vs. 2%, P = 0.005) and need for revision (8% vs. 5%, P = 0.005). Septal pacemaker lead position is associated with a lower mortality compared to apically placed leads, but a higher incidence of atrial fibrillation with higher percentage ventricular pacing. NSNA lead locations are associated with more complications and should be avoided. © 2017 Wiley Periodicals, Inc.

  15. Presentation Time Concerning System-Paced Multimedia Instructions and the Superiority of Learner Pacing

    Science.gov (United States)

    Stiller, Klaus D.; Petzold, Kirstin; Zinnbauer, Peter

    2011-01-01

    The superiority of learner-paced over system-paced instructions was demonstrated in multiple experiments. In these experiments, the system-paced presentations were highly speeded, causing cognitive overload, while the learner-paced instructions allowed adjustments of the presentational flow to the learner's needs by pacing facilities, mostly…

  16. Diagnostic accuracy of pace spikes in the electrocardiogram to diagnose paced rhythm

    DEFF Research Database (Denmark)

    Andersson, Hedvig Bille; Hansen, Marco Bo; Thorsberger, Mads

    2015-01-01

    OBJECTIVE: To determine how often cardiac resynchronization therapy (CRT) pacing systems generate visible pace spikes in the electrocardiogram (ECG). METHODS: In 46 patients treated with CRT pacing systems, we recorded ECGs during intrinsic rhythm, atrial pacing and ventricular pacing. ECGs were...

  17. Percutaneous removal of a pacing electrode

    International Nuclear Information System (INIS)

    Hoehne, U.; Schild, H.; Hake, U.

    1989-01-01

    The large number of pace-makers introduced transvenously has resulted in increasing the number of complications, amongst which infections and dislocations are prominent. It is usually necessary to remove the electrode, which can be attempted percutaneously by using a Dormia basket, a loop or forceps. Amongst the complications of this procedure are tears to the myocardium, with the risk of pericardial tamponade, or tears of the tricuspid valve leading to tricuspid insufficiency. Consequently, thoracic surgical intervention should be available if necessary. Four successful procedures are described. (orig.) [de

  18. Pace studying worldwide coke production

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Pace Consultants Inc., Houston, has started a multiclient study of world-wide petroleum coke production, examining environmental initiatives and eventually forecasting prices of fuel grade coke. Pace expects coker expansions, increased operating severity, and reduced cycle times to boost coke supply to more than 50 million metric tons/year in 2000, compared with 39.7 million metric tons in 1992. Increased supply and tightened environmental rules in countries consuming large amounts of petroleum coke will be the main factors affecting coke markets. The paper discusses coke quality and the Japanese market

  19. Comparison of Conventional versus Steerable-Catheter Guided Coronary Sinus Lead Positioning in Patients Undergoing Cardiac Resynchronization Device Implantation.

    Directory of Open Access Journals (Sweden)

    Fikret Er

    Full Text Available The aim of this study was to compare conventional versus steerable catheter guided coronary sinus (CS cannulation in patients with advanced heart failure undergoing cardiac resynchronization therapy (CRT.Steerable catheter guided coronary sinus cannulation could reduce fluoroscopy time and contrast medium use during CRT implantation.176 consecutive patients with ischemic and non-ischemic heart failure undergoing CRT implantation from January 2008 to December 2012 at the University Hospital of Cologne were identified. During the study period two concurrent CS cannulation techniques were used: standard CS cannulation technique (standard-group, n = 113 and CS cannulation using a steerable electrophysiology (EP catheter (EPCath-group, n = 63. Propensity-score matched pairs of conventional and EP-catheter guided CS cannulation made up the study population (n = 59 pairs. Primary endpoints were total fluoroscopy time and contrast medium amount used during procedure.The total fluoroscopy time was 30.9 min (interquartile range (IQR, 19.9-44.0 min in the standard-group and 23.4 min (IQR, 14.2-34-2 min in the EPCath-group (p = 0.011. More contrast medium was used in the standard-group (60.0 ml, IQR, 30.0-100 ml compared to 25.0 ml (IQR, 20.0-50.0 ml in the EPCath-group (P<0.001.Use of steerable EP catheter was associated with significant reduction of fluoroscopy time and contrast medium use in patients undergoing CRT implantation.

  20. Science Unit Plans. PACE '94.

    Science.gov (United States)

    Schoon, Kenneth J., Ed.; Wiles, Clyde A., Ed.

    This booklet contains mathematics unit plans for Biology, Chemistry, and Physical Science developed by PACE (Promoting Academic Excellence In Mathematics, Science & Technology for Workers of the 21st Century). Each unit plan contains suggested timing, objectives, skills to be acquired, workplace relationships, learning activities with suggested…

  1. PACE: A Browsable Graphical Interface.

    Science.gov (United States)

    Beheshti, Jamshid; And Others

    1996-01-01

    Describes PACE (Public Access Catalogue Extension), an alternative interface designed to enhance online catalogs by simulating images of books and library shelves to help users browse through the catalog. Results of a test in a college library against a text-based online public access catalog, including student attitudes, are described.…

  2. SU-E-T-802: Verification of Implanted Cardiac Pacemaker Doses in Intensity-Modulated Radiation Therapy: Dose Prediction Accuracy and Reduction Effect of a Lead Sheet

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of); Chung, J [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-06-15

    Purpose: To verify delivered doses on the implanted cardiac pacemaker, predicted doses with and without dose reduction method were verified using the MOSFET detectors in terms of beam delivery and dose calculation techniques in intensity-modulated radiation therapy (IMRT). Methods: The pacemaker doses for a patient with a tongue cancer were predicted according to the beam delivery methods [step-and-shoot (SS) and sliding window (SW)], intensity levels for dose optimization, and dose calculation algorithms. Dosimetric effects on the pacemaker were calculated three dose engines: pencil-beam convolution (PBC), analytical anisotropic algorithm (AAA), and Acuros-XB. A lead shield of 2 mm thickness was designed for minimizing irradiated doses to the pacemaker. Dose variations affected by the heterogeneous material properties of the pacemaker and effectiveness of the lead shield were predicted by the Acuros-XB. Dose prediction accuracy and the feasibility of the dose reduction strategy were verified based on the measured skin doses right above the pacemaker using mosfet detectors during the radiation treatment. Results: The Acuros-XB showed underestimated skin doses and overestimated doses by the lead-shield effect, even though the lower dose disagreement was observed. It led to improved dose prediction with higher intensity level of dose optimization in IMRT. The dedicated tertiary lead sheet effectively achieved reduction of pacemaker dose up to 60%. Conclusion: The current SS technique could deliver lower scattered doses than recommendation criteria, however, use of the lead sheet contributed to reduce scattered doses.Thin lead plate can be a useful tertiary shielder and it could not acuse malfunction or electrical damage of the implanted pacemaker in IMRT. It is required to estimate more accurate scattered doses of the patient with medical device to design proper dose reduction strategy.

  3. SU-E-T-802: Verification of Implanted Cardiac Pacemaker Doses in Intensity-Modulated Radiation Therapy: Dose Prediction Accuracy and Reduction Effect of a Lead Sheet

    International Nuclear Information System (INIS)

    Lee, J; Chung, J

    2015-01-01

    Purpose: To verify delivered doses on the implanted cardiac pacemaker, predicted doses with and without dose reduction method were verified using the MOSFET detectors in terms of beam delivery and dose calculation techniques in intensity-modulated radiation therapy (IMRT). Methods: The pacemaker doses for a patient with a tongue cancer were predicted according to the beam delivery methods [step-and-shoot (SS) and sliding window (SW)], intensity levels for dose optimization, and dose calculation algorithms. Dosimetric effects on the pacemaker were calculated three dose engines: pencil-beam convolution (PBC), analytical anisotropic algorithm (AAA), and Acuros-XB. A lead shield of 2 mm thickness was designed for minimizing irradiated doses to the pacemaker. Dose variations affected by the heterogeneous material properties of the pacemaker and effectiveness of the lead shield were predicted by the Acuros-XB. Dose prediction accuracy and the feasibility of the dose reduction strategy were verified based on the measured skin doses right above the pacemaker using mosfet detectors during the radiation treatment. Results: The Acuros-XB showed underestimated skin doses and overestimated doses by the lead-shield effect, even though the lower dose disagreement was observed. It led to improved dose prediction with higher intensity level of dose optimization in IMRT. The dedicated tertiary lead sheet effectively achieved reduction of pacemaker dose up to 60%. Conclusion: The current SS technique could deliver lower scattered doses than recommendation criteria, however, use of the lead sheet contributed to reduce scattered doses.Thin lead plate can be a useful tertiary shielder and it could not acuse malfunction or electrical damage of the implanted pacemaker in IMRT. It is required to estimate more accurate scattered doses of the patient with medical device to design proper dose reduction strategy

  4. Effect of short-term rapid ventricular pacing followed by pacing interruption on arterial blood pressure in healthy pigs and pigs with tachycardiomyopathy.

    Science.gov (United States)

    Skrzypczak, P; Zyśko, D; Pasławska, U; Noszczyk-Nowak, A; Janiszewski, A; Gajek, J; Nicpoń, J; Kiczak, L; Bania, J; Zacharski, M; Tomaszek, A; Jankowska, E A; Ponikowski, P; Witkiewicz, W

    2014-01-01

    Ventricular tachycardia may lead to haemodynamic deterioration and, in the case of long term persistence, is associated with the development of tachycardiomyopathy. The effect of ventricular tachycardia on haemodynamics in individuals with tachycardiomyopathy, but being in sinus rhythm has not been studied. Rapid ventricular pacing is a model of ventricular tachycardia. The aim of this study was to determine the effect of rapid ventricular pacing on blood pressure in healthy animals and those with tachycardiomyopathy. A total of 66 animals were studied: 32 in the control group and 34 in the study group. The results of two groups of examinations were compared: the first performed in healthy animals (133 examinations) and the second performed in animals paced for at least one month (77 examinations). Blood pressure measurements were taken during chronic pacing--20 min after onset of general anaesthesia, in baseline conditions (20 min after pacing cessation or 20 min after onset of general anaesthesia in healthy animals) and immediately after short-term rapid pacing. In baseline conditions significantly higher systolic and diastolic blood pressure was found in healthy animals than in those with tachycardiomyopathy. During an event of rapid ventricular pacing, a significant decrease in systolic and diastolic blood pressure was found in both groups of animals. In the group of chronically paced animals the blood pressure was lower just after restarting ventricular pacing than during chronic pacing. Cardiovascular adaptation to ventricular tachycardia develops with the length of its duration. Relapse of ventricular tachycardia leads to a blood pressure decrease more pronounced than during chronic ventricular pacing.

  5. Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

    Energy Technology Data Exchange (ETDEWEB)

    Ghafarian, Pardis [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Aghamiri, S.M.R. [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Ay, Mohammad R. [Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Research Institute for Nuclear Medicine, Tehran (Iran, Islamic Republic of); Rahmim, Arman [Johns Hopkins University, Department of Radiology, Baltimore, MD (United States); Schindler, Thomas H. [Geneva University, Cardiovascular Center, Nuclear Cardiology, Geneva (Switzerland); Ratib, Osman [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland)

    2011-02-15

    Cardiac PET/CT imaging is often performed in patients with pacemakers and implantable cardioverter defibrillator (ICD) leads. However, metallic implants usually produce artefacts on CT images which might propagate to CT-based attenuation-corrected (CTAC) PET images. The impact of metal artefact reduction (MAR) for CTAC of cardiac PET/CT images in the presence of pacemaker, ICD and ECG leads was investigated using both qualitative and quantitative analysis in phantom and clinical studies. The study included 14 patients with various leads undergoing perfusion and viability examinations using dedicated cardiac PET/CT protocols. The PET data were corrected for attenuation using both artefactual CT images and CT images corrected using the MAR algorithm. The severity and magnitude of metallic artefacts arising from these leads were assessed on both linear attenuation coefficient maps ({mu}-maps) and attenuation-corrected PET images. CT and PET emission data were obtained using an anthropomorphic thorax phantom and a dedicated heart phantom made in-house incorporating pacemaker and ICD leads attached at the right ventricle of the heart. Volume of interest-based analysis and regression plots were performed for regions related to the lead locations. Bull's eye view analysis was also performed on PET images corrected for attenuation with and without the MAR algorithm. In clinical studies, the visual assessment of PET images by experienced physicians and quantitative analysis did not reveal erroneous interpretation of the tracer distribution or significant differences when PET images were corrected for attenuation with and without MAR. In phantom studies, the mean differences between tracer uptake obtained without and with MAR were 10.16{+-}2.1% and 6.86{+-}2.1% in the segments of the heart in the vicinity of metallic ICD or pacemaker leads, and were 4.43{+-}0.5% and 2.98{+-}0.5% in segments far from the leads. Although the MAR algorithm was able to effectively improve

  6. Breath pacing system and method for pacing the respiratory activity of a subject

    NARCIS (Netherlands)

    2016-01-01

    To provide a breath pacing system and a corresponding method for pacing the respiratory activity of a subject that provide the possibility to adapt the output signal to the respiration characteristics of the subject automatically and effectively a breath pacing system (10) for pacing the respiratory

  7. Twenty-Seven Years Experience With Transvenous Pacemaker Implantation in Children Weighing <10 kg.

    Science.gov (United States)

    Konta, Laura; Chubb, Mark Henry; Bostock, Julian; Rogers, Jan; Rosenthal, Eric

    2016-02-01

    Epicardial pacemaker implantation is the favored approach in children weighing pacemaker implantation in neonates and infants from 1987. To date there have been no long-term follow-up reports of what is for many a controversial strategy. Between 1987 and 2003, 37 neonates and infants-median age 6.7 months (1 day to 3 years) and median weight 4.6 kg (2.7-10 kg)-had a permanent transvenous pacing system implanted. Pacing leads were placed into the right ventricular apex/outflow tract through a subclavian vein puncture with a redundant loop in the atrium. Three patients were lost to follow-up, 4 patients died from complications of cardiac surgery, and 2 patients had their system removed. At long-term follow-up in 28 patients at a median of 17.2 (range, 11.2-27.4) years, 10 patients have a single chamber ventricular pacemaker, 14 a dual chamber pacemaker, 3 a biventricular pacemaker, and 1 has a single chamber implantable cardioverter defibrillator. Subclavian vein patency was assessed in 26 patients. The overall subclavian vein occlusion rate was 10 of 13 (77%) 5 kg during long-term follow-up. After a median of 14.3 (range, 13.4-17.6) years of pacing, 7 patients continue with their original lead. Transvenous pacing in infants <10 kg results in encouraging short- and long-term clinical outcomes. Subclavian vein occlusion remains an important complication, occurring predominantly in those weighing <5 kg. © 2016 American Heart Association, Inc.

  8. [Management of surgery patients with implanted cardiac pacemakers].

    Science.gov (United States)

    Ugljen, R; Dadić, D; Ferek-Petrić, B; Jelić, I; Letica, D; Anić, D; Husar, J

    1995-01-01

    Patients having cardiac pacemaker implanted may be subjected to various general surgery procedures. Application of electrosurgery for the purpose of resection and coagulation, provides a high frequency electric field which produces electric voltage on the electrodes of the pacing system. This voltage may be detected within the pacing system, and various arrhythmias can be provoked in correlation with underlying rhythm and mode of pacing. Preoperative patient control and proper pacemaker programming can prevent the pacing malfunctions due to the electrosurgery application. Appropriate positioning of the neutral electrode in relation to the pacing system avoids the electric fields intersection and decreases their interference.

  9. Right heart failure due to loss of right ventricular capture in a patient with atrioventricular junction ablation and biventricular pacing.

    Science.gov (United States)

    Raffa, Santi; Fantoni, Cecilia; Restauri, Luigia; Auricchio, Angelo

    2005-10-01

    We describe the case of a patient with atrioventricular (AV) junction ablation and chronic biventricular pacing in which intermittent dysfunction of the right ventricular (RV) lead resulted in left ventricular (LV) stimulation alone and onset of severe right heart failure. Restoration of biventricular pacing by increasing device output and then performing lead revision resolved the issue. This case provides evidence that LV pacing alone in patients with AV junction ablation may lead to severe right heart failure, most likely as a result of iatrogenic mechanical dyssynchrony within the RV. Thus, probably this pacing mode should be avoided in pacemaker-dependent patients with heart failure.

  10. Large animal model of functional tricuspid regurgitation in pacing induced end-stage heart failure.

    Science.gov (United States)

    Malinowski, Marcin; Proudfoot, Alistair G; Langholz, David; Eberhart, Lenora; Brown, Michael; Schubert, Hans; Wodarek, Jeremy; Timek, Tomasz A

    2017-06-01

    Functional tricuspid regurgitation (FTR) is common in patients with advanced heart failure and frequently complicates left ventricular assist device implantation yet remains poorly understood. We set out to establish large animal model of FTR that could serve as a research platform to investigate the pathogenesis of FTR associated with end-stage heart failure. : Through right thoracotomy, ten adult sheep underwent implantation of pacemaker with epicardial LV lead, five sonomicrometry crystals on the right ventricle, and left and right ventricular telemetry pressure sensors during a beating heart off-pump procedure. After 5 ± 1 days of recovery, baseline haemodynamic, echocardiographic and sonomicrometry data were collected. Animals were paced thereafter at a rate of 220-240 beats/min until the development of heart failure and concomitant tricuspid regurgitation. : Three animals died during early recovery period and one during the pacing phase. Six surviving animals were paced for a mean of 14 ± 5 days. Cardiac function was significantly depressed compared to baseline, with LV ejection fraction falling from 69 ± 2% to 22 ± 4% ( P  tricuspid annulus (from 29.5 ± 1.6 to 36.5 ± 4.5 mm; P  = 0.01) and right ventricle (from 21.9 ± 0.2 to 30.3 ± 0.6 mm; P  = 0.03). Sonomicrometry derived contractility of RV free wall was depressed and at least moderate tricuspid insufficiency developed in all animals. : Biventricular dysfunction, tricuspid annular dilatation and significant FTR were observed in our model of ovine tachycardia induced cardiomyopathy. This animal model reflects the clinical situation of end-stage heart failure patients presenting for mechanical support. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. Procedure times, complication rates, and survival times associated with single-chamber versus dual-chamber pacemaker implantation in dogs with clinical signs of bradyarrhythmia: 54 cases (2004-2009).

    Science.gov (United States)

    Genovese, David W; Estrada, Amara H; Maisenbacher, Herbert W; Heatwole, Bonnie A; Powell, Melanie A

    2013-01-15

    To compare procedure times and major and minor complication rates associated with single-chamber versus dual-chamber pacemaker implantation and with 1-lead, 2-lead, and 3-lead pacemaker implantation in dogs with clinical signs of bradyarrhythmia. Retrospective case series. 54 dogs that underwent pacemaker implantation because of clinical signs of bradyarrhythmia. Medical records of dogs that received pacemakers between July 2004 and December 2009 were reviewed for information regarding signalment, diagnosis, pacemaker implantation, pacemaker type, complications, and survival time. Analyses were performed to determine significant differences in anesthesia time, procedure time, and outcome for dogs on the basis of pacing mode and number of pacing leads. 28 of 54 (51.9%) dogs received single-chamber pacemakers and 26 (48.1%) received dual-chamber pacemakers. Mean ± SD procedural time was significantly longer for patients with dual-chamber pacemakers (133.5 ± 51.3 minutes) than for patients with single-chamber pacemakers (94.9 ± 37.0 minutes), and procedure time increased significantly as the number of leads increased (1 lead, 102.3 ± 51.1 minutes; 2 leads, 114.9 ± 24.8 minutes; 3 leads, 158.2 ± 8.5 minutes). Rates of major and minor complications were not significantly different between dogs that received single-chamber pacemakers and those that received dual-chamber pacemakers or among dogs grouped on the basis of the number of pacing leads placed. Although dual-chamber pacemaker implantation did result in increased procedural and anesthesia times, compared with single-chamber pacemaker implantation, this did not result in a higher complication rate.

  12. Association between frequency of atrial and ventricular ectopic beats and biventricular pacing percentage and outcomes in patients with cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Mittal, Suneet; Ruwald, Anne-Christine

    2014-01-01

    -defibrillator device with data available on biventricular pacing percentage and pre-implantation 24-h Holter recordings were included. Using logistic regression, we estimated the influence of ectopic beats on the percentage of biventricular pacing. Reverse remodeling was measured as reductions in atrial and left...

  13. Novel approach to epicardial pacemaker implantation in patients with limited venous access.

    Science.gov (United States)

    Costa, Roberto; Scanavacca, Mauricio; da Silva, Kátia Regina; Martinelli Filho, Martino; Carrillo, Roger

    2013-11-01

    Limited venous access in certain patients increases the procedural risk and complexity of conventional transvenous pacemaker implantation. The purpose of this study was to determine a minimally invasive epicardial approach using pericardial reflections for dual-chamber pacemaker implantation in patients with limited venous access. Between June 2006 and November 2011, 15 patients underwent epicardial pacemaker implantation. Procedures were performed through a minimally invasive subxiphoid approach and pericardial window with subsequent fluoroscopy-assisted lead placement. Mean patient age was 46.4 ± 15.3 years (9 male [(60.0%], 6 female [40.0%]). The new surgical approach was used in patients determined to have limited venous access due to multiple abandoned leads in 5 (33.3%), venous occlusion in 3 (20.0%), intravascular retention of lead fragments from prior extraction in 3 (20.0%), tricuspid valve vegetation currently under treatment in 2 (13.3%), and unrepaired intracardiac defects in 2 (13.3%). All procedures were successful with no perioperative complications or early deaths. Mean operating time for isolated pacemaker implantation was 231.7 ± 33.5 minutes. Lead placement on the superior aspect of right atrium, through the transverse sinus, was possible in 12 patients. In the remaining 3 patients, the atrial lead was implanted on the left atrium through the oblique sinus, the postcaval recess, or the left pulmonary vein recess. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 36.8 ± 25.1 months. Epicardial pacemaker implantation through pericardial reflections is an effective alternative therapy for those patients requiring physiologic pacing in whom venous access is limited. © 2013 Heart Rhythm Society. All rights reserved.

  14. Cardiac optogenetic pacing in drosophila melanogaster using red-shifted opsins (Conference Presentation)

    Science.gov (United States)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Electrical pacing is the current gold standard for investigation of mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, this method requires an invasive surgical procedure to implant the pacing electrodes. Recently, optogenetic pacing has been developed as an alternative, non-invasive method for heartbeat pacing in animals. It induces heartbeats by shining pulsed light on transgene-generated microbial opsins which in turn activate light gated ion channels in animal hearts. However, commonly used opsins, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we expressed recently engineered red-shifted opsins, ReaChR and CsChrimson, in the heart of a well-developed animal model, Drosophila melanogaster, for the first time. Optogenetic pacing was successfully conducted in both ReaChR and CsChrimson flies at their larval, pupal, and adult stages using 617 nm excitation light pulse, enabling a much deeper tissue penetration compared to blue stimulation light. A customized high speed and ultrahigh resolution OCM system was used to non-invasively monitor the heartbeat pacing in Drosophila. Compared to previous studies on optogenetic pacing of Drosophila, higher penetration depth of optogenetic excitation light was achieved in opaque late pupal flies. Lower stimulating power density is needed for excitation at each developmental stage of both groups, which improves the safety of this technique for heart rhythm studies.

  15. Pacing in Olympic track races: competitive tactics versus best performance strategy.

    Science.gov (United States)

    Thiel, Christian; Foster, Carl; Banzer, Winfried; De Koning, Jos

    2012-01-01

    The purpose of this study was to describe pacing strategies in the 800 to 10,000-m Olympic finals. We asked 1) if Olympic finals differed from World Records, 2) how variable the pace was, 3) whether runners faced catastrophic events, and 4) for the winning strategy. Publically available data from the Beijing 2008 Olympic Games gathered by four transponder antennae under the 400-m track were analysed to extract descriptors of pacing strategies. Individual pacing patterns of 133 finalists were visualised using speed by distance plots. Six of eight plots differed from the patterns reported for World Records. The coefficient of running speed variation was 3.6-11.4%. In the long distance finals, runners varied their pace every 100 m by a mean 1.6-2.7%. Runners who were 'dropped' from the field achieved a stable running speed and displayed an endspurt. Top contenders used variable pacing strategies to separate themselves from the field. All races were decided during the final lap. Olympic track finalists employ pacing strategies which are different from World Record patterns. The observed micro- and macro-variations of pace may have implications for training programmes. Dropping off the pace of the leading group is an active step, and the result of interactive psychophysiological decision making.

  16. Permanent and temporary pacemaker implantation after orthotopic heart transplantation

    Directory of Open Access Journals (Sweden)

    Bacal Fernando

    2000-01-01

    Full Text Available PURPOSE:To determine the indication for and incidence and evolution of temporary and permanent pacemaker implantation in cardiac transplant recipients. METHODS: A retrospective review of 114 patients who underwent orthotopic heart transplantation InCor (Heart Institute USP BR between March 1985 and May 1993. We studied the incidence of and indication for temporary pacing, the relationship between pacing and rejection, the need for pemanent pacing and the clinical follow-up. RESULTS: Fourteen of 114 (12%heart transplant recipients required temporary pacing and 4 of 114 (3.5% patients required permanent pacing. The indication for temporary pacing was sinus node dysfunction in 11 patients (78.5% and atrioventricular (AV block in 3 patients (21.4%. The indication for permanent pacemaker implantation was sinus node dysfunction in 3 patients (75% and atrioventricular (AV block in 1 patient (25%. We observed rejection in 3 patients (21.4% who required temporary pacing and in 2 patients (50% who required permanent pacing. The previous use of amiodarone was observed in 10 patients (71.4% with temporary pacing. Seven of the 14 patients (50% died during follow-up. CONCLUSION: Sinus node dysfunction was the principal indication for temporary and permanent pacemaker implantation in cardiac transplant recipients. The need for pacing was related to worse prognosis after cardiac transplantation.

  17. Left and Right Ventricle Leads Switch as a Solution for TWave Oversensing - How a Good Idea Turned Out Bad.

    Science.gov (United States)

    Alzand, Bsn; Phlips, Tje; Willems, R

    2014-05-01

    A 50-year-old male with a CRT defibrillator received inappropriate ICD shocks due to T-wave oversensing. Decreasing the sensitivity to avoid T wave oversensing was not an option due to a suboptimal R-wave sensing amplitude. We decided to re-plug the LV lead in the RV port and the RV lead in the LV port. This however led to intermittent phrenic nerve stimulation due to mandatory bipolar (tip-ring) or unipolar (tip-can) pacing on the LV-lead from the RV port. Re-intervention was necessary with the implantation of an additional pacing/sensing RV lead. A software programmable choice to switch sensing and tachycardia detection from RV to LV lead could be a valuable feature in future CRT devices.

  18. Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators.

    Science.gov (United States)

    Alam, Mian Bilal; Munir, Muhammad Bilal; Rattan, Rohit; Flanigan, Susan; Adelstein, Evan; Jain, Sandeep; Saba, Samir

    2014-02-01

    Cardiac resynchronization therapy (CRT) implantable cardioverter defibrillators (ICDs) deliver high burden ventricular pacing to heart failure patients, which has a significant effect on battery longevity. The aim of this study was to investigate whether battery longevity is comparable for CRT-ICDs from different manufacturers in a contemporary cohort of patients. All the CRT-ICDs implanted at our institution from 1 January 2008 to 31 December 2010 were included in this analysis. Baseline demographic and clinical data were collected on all patients using the electronic medical record. Detailed device information was collected on all patients from scanned device printouts obtained during routine follow-up. The primary endpoint was device replacement for battery reaching the elective replacement indicator (ERI). A total of 646 patients (age 69 ± 13 years), implanted with CRT-ICDs (Boston Scientific 173, Medtronic 416, and St Jude Medical 57) were included in this analysis. During 2.7 ± 1.5 years follow-up, 113 (17%) devices had reached ERI (Boston scientific 4%, Medtronic 25%, and St Jude Medical 7%, P battery was significantly worse for Medtronic devices compared with devices from other manufacturers (94% for Boston scientific, 67% for Medtronic, and 92% for St Jude Medical, P battery longevity by manufacturer was independent of pacing burden, lead parameters, and burden of ICD therapy. There are significant discrepancies in CRT-ICD battery longevity by manufacturer. These data have important implications on clinical practice and patient outcomes.

  19. Risk perception influences athletic pacing strategy.

    Science.gov (United States)

    Micklewright, Dominic; Parry, David; Robinson, Tracy; Deacon, Greg; Renfree, Andrew; St Clair Gibson, Alan; Matthews, William J

    2015-05-01

    The objective of this study is to examine risk taking and risk perception associations with perceived exertion, pacing, and performance in athletes. Two experiments were conducted in which risk perception was assessed using the domain-specific risk taking (DOSPERT) scale in 20 novice cyclists (experiment 1) and 32 experienced ultramarathon runners (experiment 2). In experiment 1, participants predicted their pace and then performed a 5-km maximum effort cycling time trial on a calibrated Kingcycle mounted bicycle. Split times and perceived exertion were recorded every kilometer. In experiment 2, each participant predicted their split times before running a 100-km ultramarathon. Split times and perceived exertion were recorded at seven checkpoints. In both experiments, higher and lower risk perception groups were created using median split of DOSPERT scores. In experiment 1, pace during the first kilometer was faster among lower risk perceivers compared with higher risk perceivers (t(18) = 2.0, P = 0.03) and faster among higher risk takers compared with lower risk takers (t(18) = 2.2, P = 0.02). Actual pace was slower than predicted pace during the first kilometer in both the higher risk perceivers (t(9) = -4.2, P = 0.001) and lower risk perceivers (t(9) = -1.8, P = 0.049). In experiment 2, pace during the first 36 km was faster among lower risk perceivers compared with higher risk perceivers (t(16) = 2.0, P = 0.03). Irrespective of risk perception group, actual pace was slower than predicted pace during the first 18 km (t(16) = 8.9, P risk perception groups. Initial pace is associated with an individual's perception of risk, with low perceptions of risk being associated with a faster starting pace. Large differences between predicted and actual pace suggest that the performance template lacks accuracy, perhaps indicating greater reliance on momentary pacing decisions rather than preplanned strategy.

  20. Association between implantable cardioverter-defibrillator therapy and different lead positions in patients with cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Kronborg, Mads Brix; Johansen, Jens Brock; Haarbo, Jens

    2017-01-01

    /mid-ventricular/apical for the LV-LP, and as apical/non-apical for the RV-LP. Appropriate and inappropriate therapies were registered during follow-up via remote monitoring or at device interrogations. Time to event was summarized with Kaplan-Meier plots, and competed risk regression analysis was used to calculate adjusted hazard...... with an apical. We observed no significant association between appropriate therapy and LV-LP in left anterior oblique or right anterior oblique views or inappropriate therapy between any lead positions. Conclusion: An apical RV-LP is associated with an increased risk of appropriate therapy for ventricular...

  1. Reduction of the pace polarization artefact for capture detection applications by a tri-phasic stimulation pulse.

    Science.gov (United States)

    Sutton, R; Fröhlig, G; de Voogt, W G; Goethals, M; Hintringer, F; Kennergren, C; Scanu, P; Guilleman, D; Treese, N; Hartung, W M; Stammwitz, E; Muetstege, A

    2004-11-01

    This study investigated the ability to minimize pace polarization artefacts (PPA) by adjusting the post-stimulus pulse duration of a tri-phasic stimulation pulse. Adjustment of the stimulation pulse was enabled by downloading special study software into an already implanted pacemaker. Tests were performed in a total of 296 atrial leads and 311 ventricular leads. Both chronic and acute leads were included in the study. Statistically significant differences were found in the initial PPA (without any adjustment of the stimulus pulse) between atrial and ventricular leads. In addition, significant differences were observed among various lead models with respect to changes over time in the initial ventricular PPA. Successful PPA reduction was defined as a reduction of the PPA below 0.5 mV for atrial leads and below 1 mV for ventricular leads. Results show a success rate for ventricular and atrial PPA reduction of 97.8% and 98.7%, respectively. Threshold tests showed that after reduction of the PPA loss of ventricular capture can be reliably detected. However, atrial threshold tests showed many false positive evoked response detections. In addition, unexpectedly high evoked response amplitudes were observed in the atrium after reduction of the PPA. Results from additional measurements suggest that these high atrial evoked response amplitudes come from the influence of the input filter of the pacemaker.

  2. Effects of irradiation on the components of implantable pacemakers

    International Nuclear Information System (INIS)

    Kawamura, Shinji; Ono, Seiji; Kuga, Noriyuki; Shiba, Tooru; Hirose, Tetsuo; Matoba, Masaru

    2003-01-01

    The purpose of this study was to examine the effects of irradiation on implantable pacemaker components. The pacemaker was divided into three components: lead wire and electrode, battery, and electrical circuit, and each component was irradiated by X-ray and electron beams, respectively. The pacemaker parameters were measured by both telemetry data of the programmer and directly measured data from the output terminal. The following results were obtained. For the lead wire and electrode, there was no effect on the pacemaker function due to irradiation by X-ray and electron beams. In the case of battery irradiation, there was no change in battery voltage or current up to 236 Gy X-ray dose. In the electrical circuit, the pacemaker reverted to the regular beating rate (fixed-rate mode) immediately after the start of X-ray irradiation, and it continued in this mode during irradiation. In patients with their own heartbeat rhythm, changing to the fixed-rate mode may cause dangerous conditions such as ventricular fibrillation. When the accumulated irradiation dose is increased, another failure can be seen in the output voltage of the pacemaker. The pacing output voltage dropped rapidly by about 40% at 30-88 Gy. Decreasing the output voltage results in pacing disorders, and heart failure may occur. In the telemetry data of the programmer, no change in output voltage could be detected, highlighting the difference between telemetry data and actual pacing data. (author)

  3. Radiation beans characterization and implantation for study of lead equivalent individual protection device used in radiodiagnostic practices

    International Nuclear Information System (INIS)

    Pereira, Leslie Silva

    2004-01-01

    The protective shielding (IPC) must be used by occupationally exposed professionals, patients and volunteers, in order to optimize the doses who receive due to radiological practices. International and national norms establish the methodology to be adopted for determination of the IPC attenuation. In this work, the IPC had been submitted to X-rays beams with known characteristics, standardized for determination of their attenuation equivalent thickness by comparison to an experimental lead attenuation slope. This comparison technique allowed insurance estimative of the IPC attenuation equivalent thickness in mm of lead. Thus, it was possible to verify the conformity of the attenuation equivalent thickness determined experimentally and the value of the thickness indicated by the manufacturer. To carry out this work, it was necessary the implementation of experimental setups stated in the specifics norms, the study of the X-rays beams original features and the determination of combined additional filters, in order to allow the X-ray equipment used operates in compliance with Norm IEC 61331-1 IEC. The radiation quality selected is characterized by a 100 kV voltage and a 0.25 mm of copper overall filtration. The implementation of this radiation quality it was carried through of its first and second HVL (Half Value Layer). Thus, a methodology according to the international Norms has been implemented in the laboratory. The results of the present work provide suitable and useful information about radiation beams features related to the determination techniques of the attenuation properties. Once implemented the procedures for conformity evaluation of the protection devices, it will be possible to carry out specific quality control tests, which will be helpful to manufacturers, customers, as well as authorities in the radiological protection and health areas. (author)

  4. Atrioventricular Pacemaker Lead Reversal

    Directory of Open Access Journals (Sweden)

    Mehmet K Aktas, MD

    2007-01-01

    Full Text Available During cardiac surgery temporary epicardial atrial and ventricular leads are placed in case cardiac pacing is required postoperatively. We present the first reported series of patients with reversal of atrioventricular electrodes in the temporary pacemaker without any consequent deleterious hemodynamic effect. We review the electrocardiographic findings and discuss the findings that lead to the discovery of atrioventricular lead reversal.

  5. Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block.

    Science.gov (United States)

    Costa, Roberto; Silva, Katia Regina da; Martinelli Filho, Martino; Carrillo, Roger

    2017-10-01

    Few studies have characterized the surgical outcomes following epicardial pacemaker implantation in neonates with congenital complete atrioventricular block (CCAVB). This study sought to assess the long-term outcomes of a minimally invasive epicardial approach using a subxiphoid access for pacemaker implantation in neonates. Between July 2002 and February 2015, 16 consecutive neonates underwent epicardial pacemaker implantation due to CCAVB. Among these, 12 (75.0%) had congenital heart defects associated with CCAVB. The patients had a mean age of 4.7 ± 5.3 days and nine (56.3%) were female. Bipolar steroid-eluting epicardial leads were implanted in all patients through a minimally invasive subxiphoid approach and fixed on the diaphragmatic ventricular surface. The pulse generator was placed in an epigastric submuscular position. All procedures were successful, with no perioperative complications or early deaths. Mean operating time was 90.2 ± 16.8 minutes. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 4.1 ± 3.9 years. Three children underwent pulse generator replacement due to normal battery depletion at 4.0, 7.2, and 9.0 years of age without the need of ventricular lead replacement. There were two deaths at 12 and 325 days after pacemaker implantation due to bleeding from thrombolytic use and progressive refractory heart failure, respectively. Epicardial pacemaker implantation through a subxiphoid approach in neonates with CCAVB is technically feasible and associated with excellent surgical outcomes and pacing lead longevity.

  6. Extending the use of the pacing pulmonary artery catheter for safe minimally invasive cardiac surgery.

    Science.gov (United States)

    Levin, Ricardo; Leacche, Marzia; Petracek, Michael R; Deegan, Robert J; Eagle, Susan S; Thompson, Annemarie; Pretorius, Mias; Solenkova, Nataliya V; Umakanthan, Ramanan; Brewer, Zachary E; Byrne, John G

    2010-08-01

    In this study, the therapeutic use of pacing pulmonary artery catheters in association with minimally invasive cardiac surgery was evaluated. A retrospective study. A single institutional university hospital. Two hundred twenty-four consecutive patients undergoing minimally invasive cardiac surgery through a small (5-cm) right anterolateral thoracotomy using fibrillatory arrest without aortic cross-clamping. Two hundred eighteen patients underwent mitral valve surgery (97%) alone or in combination with other procedures. Six patients underwent other cardiac operations. In all patients, the pacing pulmonary artery catheter was used intraoperatively to induce ventricular fibrillation during the cooling period, and in the postoperative period it also was used in 37 (17%) patients who needed to be paced, mainly for bradyarrhythmias (51%). There were no complications related to the insertion of the catheters. Six (3%) patients experienced a loss of pacing capture, and 2 (1%) experienced another complication requiring the surgical removal of the catheter. Seven (3%) patients needed postoperative implantation of a permanent pacemaker. In combination with minimally invasive cardiac surgery, pacing pulmonary artery catheters were therapeutically useful to induce ventricular fibrillatory arrest intraoperatively and for obtaining pacing capability in the postoperative period. Their use was associated with a low number of complications. Copyright 2010 Elsevier Inc. All rights reserved.

  7. CAMAC interface module for PACE ADC system

    Energy Technology Data Exchange (ETDEWEB)

    Dalton, C G; Mischke, R E [Los Alamos Scientific Lab., N.Mex. (USA); Scott, D T

    1977-03-15

    This report describes a CAMAC module designed to buffer and transfer data from the Tennelec multiplexed ADC system called PACE to a computer. It can be operated in either of two modes: as an eight-deep, first-in-first-out (FIFO) circular buffer, or in channel mode with a single buffer reserved for each PACE channel.

  8. Web Tools: Keeping Learners on Pace

    Science.gov (United States)

    Kosloski, Mickey

    2016-01-01

    One of the greatest challenges in teaching technology and engineering is pacing. Some students grasp new technological concepts quickly, while others need repetition and may struggle to keep pace. This poses an obstacle for the technology and engineering teacher, and is particularly true when teaching students to build a website. However, there…

  9. 42 CFR 460.60 - PACE organizational structure.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false PACE organizational structure. 460.60 Section 460... ELDERLY (PACE) PACE Administrative Requirements § 460.60 PACE organizational structure. (a) A PACE organization must be, or be a distinct part of, one of the following: (1) An entity of city, county, State, or...

  10. Hemodynamic stress testing using pacing tachycardia

    International Nuclear Information System (INIS)

    McKay, R.G.; Grossman, W.

    1986-01-01

    A trial pacing was first introduced in 1967 by Sowton and co-workers as a stress test which could be used in the cardiac catheterization laboratory to evaluate patients with schemic heart disease. Sowton noted that artificially increasing the heart rate by pacing the right atrium could usually induce angina in patients with symptomatic coronary artery disease. Since Sowton's original description, numerous investigators have described characteristic pacing-induced electrocardiographic changes, derangements of myocardial lactate metabolism, hemodynamic abnormalities, regional wall abnormalities, and defects in thallium scintigraphy. Although agreement on the overall usefulness of atrial pacing has not been uniform, it is clear that the technique can safely and reliably induce ischemia in most patients with coronary artery disease and that information obtained during the pacing-induced ischemic state can often be helpful in the diagnosis and treatment of the patient's underlying disease

  11. Surface ECG and Fluoroscopy are Not Predictive of Right Ventricular Septal Lead Position Compared to Cardiac CT.

    Science.gov (United States)

    Rowe, Matthew K; Moore, Peter; Pratap, Jit; Coucher, John; Gould, Paul A; Kaye, Gerald C

    2017-05-01

    Controversy exists regarding the optimal lead position for chronic right ventricular (RV) pacing. Placing a lead at the RV septum relies upon fluoroscopy assisted by a surface 12-lead electrocardiogram (ECG). We compared the postimplant lead position determined by ECG-gated multidetector contrast-enhanced computed tomography (MDCT) with the position derived from the surface 12-lead ECG. Eighteen patients with permanent RV leads were prospectively enrolled. Leads were placed in the RV septum (RVS) in 10 and the RV apex (RVA) in eight using fluoroscopy with anteroposterior and left anterior oblique 30° views. All patients underwent MDCT imaging and paced ECG analysis. ECG criteria were: QRS duration; QRS axis; positive or negative net QRS amplitude in leads I, aVL, V1, and V6; presence of notching in the inferior leads; and transition point in precordial leads at or after V4. Of the 10 leads implanted in the RVS, computed tomography (CT) imaging revealed seven to be at the anterior RV wall, two at the anteroseptal junction, and one in the true septum. For the eight RVA leads, four were anterior, two septal, and two anteroseptal. All leads implanted in the RVS met at least one ECG criteria (median 3, range 1-6). However, no criteria were specific for septal position as judged by MDCT. Mean QRS duration was 160 ± 24 ms in the RVS group compared with 168 ± 14 ms for RVA pacing (P = 0.38). We conclude that the surface ECG is not sufficiently accurate to determine RV septal lead tip position compared to cardiac CT. © 2017 Wiley Periodicals, Inc.

  12. Left Phrenic Nerve Stimulation Due to Breakage of the Endocardial Right Ventricular Lead at the Costoclavicular Ligament

    Directory of Open Access Journals (Sweden)

    Mariko Fujimori, MD

    2007-01-01

    Full Text Available A 78-year-old man with a permanent pacemaker (PM implanted in his left prepectoral area reported twitches in his left lateral abdominal region. Chest X-rays revealed a broken right atrial (RA lead and a fracture of the right ventricular (RV lead at the left costoclavicular ligament. The electrocardiogram (ECG and the Holler ECG revealed atrial fibrillation (AF and an improperly functioning PM. We observed that the twitching seemed to correspond with each pacing beat and that it did not appear with his own beat. We suspected that the twitching was due to electric current leakage from the broken RV lead. We performed a PM re-implantation with a screw-in RV lead using the extrathoracic approach. After re-implantation the twitching disappeared. Costoclavicular ligament related electrode lead fractures are not uncommon and electric current leaks can be a source of problems in cardiac pacing. In this case, the electric current leak from the broken RV lead at the costoclavicular ligament stimulated the left phrenic nerve.

  13. Beam Profile Disturbances from Implantable Pacemakers or Implantable Cardioverter-Defibrillator Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Gossman, Michael S., E-mail: mgossman@tsrcc.com [Tri-State Regional Cancer Center, Medical Physics Section, Ashland, KY (United States); Comprehensive Heart and Vascular Associates, Heart and Vascular Center, Ashland, KY (United States); Medtronic, Inc., External Research Program, Mounds View, MN (United States); Nagra, Bipinpreet; Graves-Calhoun, Alison; Wilkinson, Jeffrey [Tri-State Regional Cancer Center, Medical Physics Section, Ashland, KY (United States); Comprehensive Heart and Vascular Associates, Heart and Vascular Center, Ashland, KY (United States); Medtronic, Inc., External Research Program, Mounds View, MN (United States)

    2011-01-01

    The medical community is advocating for progressive improvement in the design of implantable cardioverter-defibrillators and implantable pacemakers to accommodate elevations in dose limitation criteria. With advancement already made for magnetic resonance imaging compatibility in some, a greater need is present to inform the radiation oncologist and medical physicist regarding treatment planning beam profile changes when such devices are in the field of a therapeutic radiation beam. Treatment plan modeling was conducted to simulate effects induced by Medtronic, Inc.-manufactured devices on therapeutic radiation beams. As a continuation of grant-supported research, we show that radial and transverse open beam profiles of a medical accelerator were altered when compared with profiles resulting when implantable pacemakers and cardioverter-defibrillators are placed directly in the beam. Results are markedly different between the 2 devices in the axial plane and the sagittal planes. Vast differences are also presented for the therapeutic beams at 6-MV and 18-MV x-ray energies. Maximum changes in percentage depth dose are observed for the implantable cardioverter-defibrillator as 9.3% at 6 MV and 10.1% at 18 MV, with worst distance to agreement of isodose lines at 2.3 cm and 1.3 cm, respectively. For the implantable pacemaker, the maximum changes in percentage depth dose were observed as 10.7% at 6 MV and 6.9% at 18 MV, with worst distance to agreement of isodose lines at 2.5 cm and 1.9 cm, respectively. No differences were discernible for the defibrillation leads and the pacing lead.

  14. The "neuro-mapping locator" software. A real-time intraoperative objective paraesthesia mapping tool to evaluate paraesthesia coverage of the painful zone in patients undergoing spinal cord stimulation lead implantation.

    Science.gov (United States)

    Guetarni, F; Rigoard, P

    2015-03-01

    Conventional spinal cord stimulation (SCS) generates paraesthesia, as the efficacy of this technique is based on the relationship between the paraesthesia provided by SCS on the painful zone and an analgesic effect on the stimulated zone. Although this basic postulate is based on clinical evidence, it is clear that this relationship has never been formally demonstrated by scientific studies. There is a need for objective evaluation tools ("transducers") to transpose electrical signals to clinical effects and to guide therapeutic choices. We have developed a software at Poitiers University hospital allowing real-time objective mapping of the paraesthesia generated by SCS lead placement and programming during the implantation procedure itself, on a touch screen interface. The purpose of this article is to describe this intraoperative mapping software, in terms of its concept and technical aspects. The Neuro-Mapping Locator (NML) software is dedicated to patients with failed back surgery syndrome, candidates for SCS lead implantation, to actively participate in the implantation procedure. Real-time geographical localization of the paraesthesia generated by percutaneous or multicolumn surgical SCS lead implanted under awake anaesthesia allows intraoperative lead programming and possibly lead positioning to be modified with the patient's cooperation. Software updates should enable us to refine objectives related to the use of this tool and minimize observational biases. The ultimate goals of NML software should not be limited to optimize one specific device implantation in a patient but also allow to compare instantaneously various stimulation strategies, by characterizing new technical parameters as "coverage efficacy" and "device specificity" on selected subgroups of patients. Another longer-term objective would be to organize these predictive factors into computer science ontologies, which could constitute robust and helpful data for device selection and programming

  15. Synchronous intra-myocardial ventricular pacing without crossing the tricuspid valve or entering the coronary sinus

    Energy Technology Data Exchange (ETDEWEB)

    Konecny, Tomas; DeSimone, Christopher V.; Friedman, Paul A.; Bruce, Charles [Department of Medicine, Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Asirvatham, Samuel J., E-mail: asirvatham.samuel@mayo.edu [Department of Medicine, Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Department of Pediatric and Adolescent Medicine, Pediatric Cardiology, Mayo Clinic, Rochester, MN (United States)

    2013-05-15

    Ventricular pacing is most commonly performed at the right ventricular (RV) apex. This is not without risk as placement requires crossing the tricuspid valve (TV) and may cause valvular dysfunction and dyssynchronous activation of the ventricles. The fact that the tricuspid valve lies more apically than the mitral valve allows for the possibility of pacing the ventricles from the right atrium (RA) via the “atrio-ventricular septum” without crossing the TV or entering the coronary sinus (CS). In order to mitigate far field activation inherent to current pacing technology, we constructed a novel lead in which the cathode and anode are both intra-myocardial. We demonstrate safety and efficacy of this novel lead for ventricular pacing at the atrio-ventricular septum in canines, including improved synchronous activation of both ventricles, improved differentiation in ventricular versus atrial sensing, while providing reliable ventricular capture, opening novel and a potentially safer alternative to human cardiac resynchronization therapy.

  16. Early Right Ventricular Apical Pacing-Induced Gene Expression Alterations Are Associated with Deterioration of Left Ventricular Systolic Function

    Directory of Open Access Journals (Sweden)

    Haiyan Xu

    2017-01-01

    Full Text Available The chronic high-dose right ventricular apical (RVA pacing may have deleterious effects on left ventricular (LV systolic function. We hypothesized that the expression changes of genes regulating cardiomyocyte energy metabolism and contractility were associated with deterioration of LV function in patients who underwent chronic RVA pacing. Sixty patients with complete atrioventricular block and preserved ejection fraction (EF who underwent pacemaker implantation were randomly assigned to either RVA pacing (n=30 group or right ventricular outflow tract (RVOT pacing (n=30 group. The mRNA levels of OPA1 and SERCA2a were significantly lower in the RVA pacing group at 1 month’s follow-up (both p<0.001. Early changes in the expression of selected genes OPA1 and SERCA2a were associated with deterioration in global longitudinal strain (GLS that became apparent months later (p=0.002 and p=0.026, resp. The altered expressions of genes that regulate cardiomyocyte energy metabolism and contractility measured in the peripheral blood at one month following pacemaker implantation were associated with subsequent deterioration in LV dyssynchrony and function in patients with preserved LVEF, who underwent RVA pacing.

  17. Systematic review and meta-analysis of left ventricular endocardial pacing in advanced heart failure: Clinically efficacious but at what cost?

    Science.gov (United States)

    Graham, Adam J; Providenica, Rui; Honarbakhsh, Shohreh; Srinivasan, Neil; Sawhney, Vinit; Hunter, Ross; Lambiase, Pier

    2018-04-01

    Cardiac resynchronization using a left ventricular (LV) epicardial lead placed in the coronary sinus is now routinely used in the management of heart failure patients. LV endocardial pacing is an alternative when this is not feasible, with outcomes data sparse. To review the available evidence on the efficacy and safety of endocardial LV pacing via meta-analysis. EMBASE, MEDLINE, and COCHRANE databases with the search term "endocardial biventricular pacing" or "endocardial cardiac resynchronization" or "left ventricular endocardial" or "endocardial left ventricular." Comparisons of pre-and post-QRS width, LV ejection fraction (LVEF), and New York Heart Association (NYHA) functional classification was performed, and mean differences (and respective 95% confidence interval [CI]) applied as a measurement of treatment effect. Fifteen studies, including 362 patients, were selected. During a mean follow-up of 40 ± 24.5 months, death occurred in 72 patients (11 per 100 patient-years). Significant improvements in LVEF (mean difference 7.9%, 95% CI 5-10%, P < 0.0001; I 2  = 73%), QRS width (mean difference: -41% 95% -75 to -7%; P < 0.0001; I 2  = 94%), and NYHA class (mean difference: -1.06, 95% CI -1.2 to -0.9, P < 0.0001; I 2  = 60%), (all P < 0.0001) occurred. Stroke rate was 3.3-4.2 per 100 patient-years, which is higher than equivalent heart failure trial populations and recent meta-analysis that included small case series. LV endocardial lead implantation is a potentially efficacious alternative to CS lead placement, but preliminary data suggest a potentially higher risk of stroke during follow-up when compared to the expected incidence of stroke in similar cohorts of patients. © 2018 Wiley Periodicals, Inc.

  18. Electrophysiology Catheter-Facilitated coronary sinus cannulation and implantation of cardiac resynchronization therapy systems

    Directory of Open Access Journals (Sweden)

    Antonis S. Manolis, MD, FESC, FACC, FHRS

    2018-01-01

    Full Text Available Background: Cardiac resynchronization therapy (CRT device implantation is hampered by difficult placement of the left ventricular (LV lead. We have routinely used a steerable electrophysiology catheter to guide coronary sinus (CS cannulation and facilitate LV lead positioning. The aim of this prospective study is to present our results with this approach in 138 consecutive patients receiving a CRT device over 10 years. Methods: The study included 120 men and 18 women, aged 64.8±11.4 years, with coronary disease (n=63, cardiomyopathy (n=72, or other disease (n=3, and mean ejection fraction of 24.5±4.5%. Devices were implanted for refractory heart failure and dyssynchrony, all but 2 in the presence of left bundle branch block. Implanted devices included biventricular pacemakers (CRT-P (n=33 and cardioverter defibrillators (CRT-D (n=105. Results: Using the electrophysiology catheter, the CS could be engaged in 134 (97.1% patients. In 4 patients failing CS cannulation, a dual-chamber device was implanted in 2, and bifocal right ventricular pacing was effected in 2. Bifocal (n=2 or conventional (n=1 systems were implanted in another 3 patients, in whom the LV lead got dislodged (n=2 or removed because of local dissection (n=1. Thus, finally, a CRT system was successfully established in 131 (94.9% patients. There were 3 patients with CS dissection, of whom 1 was complicated by cardiac tamponade managed with pericardiocentesis. There were no perioperative deaths. During follow-up (31.0±21.2 months, clinical improvement was reported by 108 (82.4% patients. Conclusion: Routine use of an electrophysiology catheter greatly facilitated CS cannulation and successful LV lead placement in ∼95% of patients undergoing CRT system implantation. Keywords: heart failure, cardiac resynchronization therapy, implantable cardioverter defibrillator, coronary sinus, left ventricular lead

  19. Atrial antitachycardia pacing and managed ventricular pacing in bradycardia patients with paroxysmal or persistent atrial tachyarrhythmias: the MINERVA randomized multicentre international trial

    Science.gov (United States)

    Boriani, Giuseppe; Tukkie, Raymond; Manolis, Antonis S.; Mont, Lluis; Pürerfellner, Helmut; Santini, Massimo; Inama, Giuseppe; Serra, Paolo; de Sousa, João; Botto, Giovanni Luca; Mangoni, Lorenza; Grammatico, Andrea; Padeletti, Luigi

    2014-01-01

    Aims Atrial fibrillation (AF) is a common comorbidity in bradycardia patients. Advanced pacemakers feature atrial preventive pacing and atrial antitachycardia pacing (DDDRP) and managed ventricular pacing (MVP), which minimizes unnecessary right ventricular pacing. We evaluated whether DDDRP and MVP might reduce mortality, morbidity, or progression to permanent AF when compared with standard dual-chamber pacing (Control DDDR). Methods and results In a randomized, parallel, single-blind, multi-centre trial we enrolled 1300 patients with bradycardia and previous atrial tachyarrhythmias, in whom a DDDRP pacemaker had recently been implanted. History of permanent AF and third-degree atrioventricular block were exclusion criteria. After a 1-month run-in period, 1166 eligible patients, aged 74 ± 9 years, 50% females, were randomized to Control DDDR, DDDRP + MVP, or MVP. Analysis was intention-to-treat. The primary outcome, i.e. the 2-year incidence of a combined endpoint composed of death, cardiovascular hospitalizations, or permanent AF, occurred in 102/385 (26.5%) Control DDDR patients, in 76/383 (19.8%) DDDRP + MVP patients [hazard ratio (HR) = 0.74, 95% confidence interval 0.55–0.99, P = 0.04 vs. Control DDDR] and in 85/398 (21.4%) MVP patients (HR = 0.89, 95% confidence interval 0.77–1.03, P = 0.125 vs. Control DDDR). When compared with Control DDDR, DDDRP + MVP reduced the risk for AF longer than 1 day (HR = 0.66, 95% CI 0.52–0.85, P MVP is superior to standard dual-chamber pacing. The primary endpoint was significantly lowered through the reduction of the progression of atrial tachyarrhythmias to permanent AF. ClinicalTrials.gov Identifier NCT00262119. PMID:24771721

  20. A pacemaker magnet check alone is sufficient for the majority of patients postpacemaker implant.

    Science.gov (United States)

    Jones, Michael A; Wong, Kelvin C K; Qureshi, Norman; Rajappan, Kim; Bashir, Yaver; Betts, Timothy R

    2014-12-01

    Patients postpacemaker implant can undergo a full assessment by pacing system programmer (PSP) or a magnet check. The former takes longer, but provides more detailed information; a magnet-mode assessment is faster, but provides only capture data in an asynchronous pacing mode. A magnet-mode assessment alone may be sufficient in most cases, and current clinical practice varies considerably. A retrospective single-center assessment of all pacemaker implants receiving PSP and magnet checks between September 2009 and April 2010. Patient records were reviewed. The results of PSP and magnet checks and any subsequent device-related management were noted. A total of 168 patients underwent pacemaker implantation, magnet-mode assessment, and then PSP interrogation during this period. Magnet-mode assessment revealed a problem in only one patient-failure of atrial capture, leading to subsequent atrial lead repositioning. None of the remaining 167 patients have a serious problem at PSP interrogation; six had minor issues at PSP check, none of which required repeat surgical intervention. The magnet-mode test only provides information on lead capture in an asynchronous pacing mode, which is the most essential data postoperatively. Our study has suggested that a magnet-mode assessment without PSP interrogation may be sufficient in the immediate postimplant assessment of these patients. Routine postimplant PSP interrogation is time consuming, labor intensive, and adds only minimal additional benefit to the safe management of these patients above and beyond a magnet check, coupled with informed assessment of the associated electrocardiogram/rhythm strip, clinical examination, and chest x-ray. ©2014 Wiley Periodicals, Inc.

  1. PACE: Proactively Secure Accumulo with Cryptographic Enforcement

    Science.gov (United States)

    2017-05-27

    will be replaced with the values from the decrypted destination field. PACE encrypts data using AES and supports the following modes: CTR, CFB, CBC, OFB...2) Searchable Encryption : PACE also support searching for encrypted data. This is done using AES in SIV mode [11] to provide deterministic encryption ...row ”Alphabet”), then the search term is encrypted deterministically, and that term is searched on the server. Because AES does not preserve the

  2. Optogenetic pacing in Drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Alex, Aneesh; Li, Airong; Men, Jing; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2016-03-01

    A non-invasive, contact-less cardiac pacing technology can be a powerful tool in basic cardiac research and in clinics. Currently, electrical pacing is the gold standard for cardiac pacing. Although highly effective in controlling the cardiac function, the invasive nature, non-specificity to cardiac tissues and possible tissue damage limits its capabilities. Optical pacing of heart is a promising alternative, which is non-invasive and more specific, has high spatial and temporal precision, and avoids shortcomings in electrical stimulation. Optical coherence tomography has been proved to be an effective technique in non-invasive imaging in vivo with ultrahigh resolution and imaging speed. In the last several years, non-invasive specific optical pacing in animal hearts has been reported in quail, zebrafish, and rabbit models. However, Drosophila Melanogaster, which is a significant model with orthologs of 75% of human disease genes, has rarely been studied concerning their optical pacing in heart. Here, we combined optogenetic control of Drosophila heartbeat with optical coherence microscopy (OCM) technique for the first time. The light-gated cation channel, channelrhodopsin-2 (ChR2) was specifically expressed by transgene as a pacemaker in drosophila heart. By stimulating the pacemaker with 472 nm pulsed laser light at different frequencies, we achieved non-invasive and more specific optical control of the Drosophila heart rhythm, which demonstrates the wide potential of optical pacing for studying cardiac dynamics and development. Imaging capability of our customized OCM system was also involved to observe the pacing effect visually. No tissue damage was found after long exposure to laser pulses, which proved the safety of optogenetic control of Drosophila heart.

  3. Increased heart rate caused by atrial pacing with the closed-loop stimulation function prevented micturition syncope

    Directory of Open Access Journals (Sweden)

    Tatsuo Haraki, MD,PhD

    2013-10-01

    Full Text Available A 70-year-old man had been experiencing syncope several times a year. We implanted a DDD pacemaker with closed-loop stimulation (CLS function. When he urinated early in the morning, his increased atrial pacing rates elevated his heart rate (HR during and after micturition. After implantation of the DDD-CLS mode, he did not experience symptoms. In contrast, in the DDD-R mode, his intrinsic HR changed to atrial pacing after micturition but decreased to the basal rate within 2 min, and he experienced a sense of cold perspiration and presyncope. Increased HRs caused by atrial pacing with the CLS function were useful in the prevention of micturition syncope.

  4. Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system.

    Science.gov (United States)

    Abiri, Parinaz; Abiri, Ahmad; Packard, René R Sevag; Ding, Yichen; Yousefi, Alireza; Ma, Jianguo; Bersohn, Malcolm; Nguyen, Kim-Lien; Markovic, Dejan; Moloudi, Shervin; Hsiai, Tzung K

    2017-07-21

    Pacemakers have existed for decades as a means to restore cardiac electrical rhythms. However, lead-related complications have remained a clinical challenge. While market-released leadless devices have addressed some of the issues, their pacer-integrated batteries cause new health risks and functional limitations. Inductive power transfer enables wireless powering of bioelectronic devices; however, Specific Absorption Rate and size limitations reduce power efficiency for biomedical applications. We designed a remote-controlled system in which power requirements were significantly reduced via intermittent power transfer to control stimulation intervals. In parallel, the cardiac component was miniaturized to facilitate intravascular deployment into the anterior cardiac vein. Given size constraints, efficiency was optimal via a circular receiver coil wrapped into a half-cylinder with a meandering tail. The pacemaker was epicardially tested in a euthanized pig at 60 beats per minute, 2 V amplitude, and 1 ms pulse width, restoring mean arterial pressure from 0 to 37 mmHg. Power consumption was 1 mW at a range of > 3 cm with no misalignment and at 2 cm with 45° displacement misalignment, 45° x-axis angular misalignment, or 45° y-axis angular misalignment. Thus, we demonstrated a remote-controlled miniaturized pacing system with low power consumption, thereby providing a basis for the next generation of wireless implantable devices.

  5. Lead inclusions in aluminium

    International Nuclear Information System (INIS)

    Johnson, E.; Johansen, A.; Sarholt-Kristensen, L.; Andersen, H.H.; Grabaek, L.; Bohr, J.

    1990-01-01

    Ion implantation at room temperature of lead into aluminum leads to spontaneous phase separation and formation of lead precipitates growing topotactically with the matrix. Unlike the highly pressurized (∼ 1-5 GPa) solid inclusions formed after noble gas implantations, the pressure in the lead precipitates is found to be less than 0.12 GPa. Recently the authors have observed the result that the lead inclusions in aluminum exhibit both superheating and supercooling. In this paper they review and elaborate on these results. Small implantation-induced lead precipitates embedded in an aluminum matrix were studied by x-ray diffraction

  6. Altering Pace Control and Pace Regulation: Attentional Focus Effects during Running.

    Science.gov (United States)

    Brick, Noel E; Campbell, Mark J; Metcalfe, Richard S; Mair, Jacqueline L; Macintyre, Tadhg E

    2016-05-01

    To date, there are no published studies directly comparing self-controlled (SC) and externally controlled (EC) pace endurance tasks. However, previous research suggests pace control may impact on cognitive strategy use and effort perceptions. The primary aim of this study was to investigate the effects of manipulating perception of pace control on attentional focus, physiological, and psychological outcomes during running. The secondary aim was to determine the reproducibility of self-paced running performance when regulated by effort perceptions. Twenty experienced endurance runners completed four 3-km time trials on a treadmill. Subjects completed two SC pace trials, one perceived exertion clamped (PE) trial, and one EC pace time trial. PE and EC were completed in a counterbalanced order. Pacing strategy for EC and perceived exertion instructions for PE replicated the subjects' fastest SC time trial. Subjects reported a greater focus on cognitive strategies such as relaxing and optimizing running action during EC than during SC. The mean HR was 2% lower during EC than that during SC despite an identical pacing strategy. Perceived exertion did not differ between the three conditions. However, increased internal sensory monitoring coincided with elevated effort perceptions in some subjects during EC and a 10% slower completion time for PE (13.0 ± 1.6 min) than that for SC (11.8 ± 1.2 min). Altering pace control and pace regulation impacted on attentional focus. External control over pacing may facilitate performance, particularly when runners engage attentional strategies conducive to improved running efficiency. However, regulating pace based on effort perceptions alone may result in excessive monitoring of bodily sensations and a slower running speed. Accordingly, attentional focus interventions may prove beneficial for some athletes to adopt task-appropriate attentional strategies to optimize performance.

  7. Positive pacing in elite IRONMAN triathletes.

    Science.gov (United States)

    Angehrn, Nicole; Rüst, Christoph A.; Nikolaidis, Pantelis T.; Rosemann, Thomas; Knechtle, Beat

    2016-12-31

    Pacing is known to influence athletic performance. For the Ironman triathlon program, a positive pacing strategy, i.e., the continuous decrease of speed over time was recommended. By analyzing split times, we assessed the pacing strategies of the top 100 finishers of the cycling part of 13 Ironman races and of the running part of 11 Ironman races taking place in 2014. Furthermore, sex-associated differences in performance and pacing strategies were calculated. We analyzed 7,687 cycling and 11,894 running split times of 1,392 triathletes (1,263 men, 129 women). Changes in speed were assessed using mixed-effects regression analyses. A continuous decrease in speed was observed during cycling in 10/13 races, and during running in 11/11 races. In 6/13 races, women decreased their speed during cycling significantly more than men. The running part showed no significant difference of changes in speed between the sexes. In summary, in the Ironman races evaluated, a positive pacing strategy was adopted in most races. Women were slower than men in 6/13 cycling races, but there was no difference between men and women in the run splits. Women used the same pacing strategy as men.

  8. Non-invasive red light optogenetic pacing and optical coherence microscopy (OCM) imaging for drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Cardiac pacing could be a powerful tool for investigating mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, traditional electrical pacing using pacemaker requires an invasive surgical procedure. Electrical currents from the implanted electrodes can also cause damage to heart tissue, further restricting its utility. Optogenetic pacing has been developed as a promising, non-invasive alternative to electrical stimulation for controlling animal heart rhythms. It induces heart contractions by shining pulsed light on transgene-generated microbial opsins, which in turn activate the light gated ion channels in animal hearts. However, commonly used opsins in optogenetic pacing, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we performed optogenetic pacing by expression of recently engineered red-shifted microbial opsins, ReaChR and CsChrimson, in a well-established animal model, Drosophila melanogaster, using the 617 nm stimulation light pulses. The OCM technique enables non-invasive optical imaging of animal hearts with high speed and ultrahigh axial and transverse resolutions. We integrated a customized OCM system with the optical stimulation system to monitor the optogenetic pacing noninvasively. The use of red-sifted opsins enabled deeper penetration of simulating light at lower power, which is promising for applications of optogenetic pacing in mammalian cardiac pathology studies or clinical treatments in the future.

  9. Retrospective analysis of mode survival, reliability of atrial sensing and incidence of atrial tachyarrhythmias in 307 single-lead VDD pacemaker patients.

    Science.gov (United States)

    Zupan, Igor; Lipar, Luka; Zizek, David; Boute, Wim; Vidmar, Masa; Gabrijelcic, Tone; Rakovec, Peter; Brecelj, Ales

    2006-10-01

    The aim of this retrospective analysis was to investigate VDD mode survival, development of atrial tachyarrhythmias (AT), and long-term atrial sensing performance of VDD pacing systems. We implanted single-lead VDD pacemakers in patients with isolated atrioventricular block and performed a retrospective analysis of 307 patients who had their devices implanted between May 1994 and September 2001. In 39 patients (12.7%), the pacing mode had to be reprogrammed to a single-chamber ventricular pacing mode, mostly due to permanent AT. In 16 of these patients, the atrial sensing safety margin was less than 150%. The atrial sensing safety margin was insufficient, i.e. less than 100% in only seven patients. Although only 12 (3.9%) of the patients had a history of paroxysmal AT at the time of pacemaker implantation, 200 (65%) patients presented with AT during follow-up. The mean AT burden at the last follow-up was 2.5%. These data illustrate that single-lead VDD pacemakers can be applied without serious complications in a highly selected group of patients. Our main concern is the development of AT in a large part of our population. Over a 10-year period, two thirds of our patients presented with AT.

  10. First reported experience with intramuscular diaphragm pacing in replacing positive pressure mechanical ventilators in children.

    Science.gov (United States)

    Onders, Raymond P; Ponsky, Todd A; Elmo, MaryJo; Lidsky, Karen; Barksdale, Edward

    2011-01-01

    Diaphragm pacing (DP) has been shown to successfully replace mechanical ventilators for adult tetraplegic patients with chronic respiratory insufficiency. This is the first report of DP in ventilator-dependent children. This was a prospective interventional experience under institutional review board approval. Diaphragm pacing involves outpatient laparoscopic diaphragm motor point mapping to identify the site where stimulation causes maximum diaphragm contraction with implantation of 4 percutaneous intramuscular electrodes. Diaphragm conditioning ensues to wean the child from the ventilator. Six children were successfully implanted ranging from 5 to 17 years old with the smallest 15 kg in weight. Length of time on mechanical ventilation ranged from 11 days to 7.6 years with an average of 3.2 years. In all patients, DP provided tidal volumes above basal needs. Five of the patients underwent a home-based weaning program, whereas one patient who was implanted only 11 days post spinal cord injury never returned to the ventilator with DP use. Another patient was weaned from the ventilator full time but died of complications of his underlying brain stem tumor. The remaining patients weaned from the ventilator for over 14 hours a day and/or are actively conditioning their diaphragms. Diaphragm pacing successfully replaced mechanical ventilators, which improves quality of life. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Comparison of right ventricular septal pacing and right ventricular apical pacing in patients receiving cardiac resynchronization therapy defibrillators: the SEPTAL CRT Study

    Science.gov (United States)

    Leclercq, Christophe; Sadoul, Nicolas; Mont, Lluis; Defaye, Pascal; Osca, Joaquim; Mouton, Elisabeth; Isnard, Richard; Habib, Gilbert; Zamorano, Jose; Derumeaux, Genevieve; Fernandez-Lozano, Ignacio; Dupuis, Jean-Marc; Rouleau, Frédéric; Tassin, Aude; Bordachar, Pierre; Clémenty, Jacques; Lafitte, Stephane; Ploux, Sylvan; Reant, Patricia; Ritter, Philippe; Defaye, Pascal; Jacon, Peggy; Mondesert, Blandine; Saunier, Carole; Vautrin, Estelle; Kacet, Salem; Guedon-Moreau, Laurence; Klug, Didier; Kouakam, Claude; Marechaux, Sylvestre; Marquie, Christelle; Polge, Anne Sophie; Richardson, Marjorie; Chevallier, Philippe; De Breyne, Brigitte; Lotek, Marcin M.; Nonin, Emilie; Pineau, Julien; Deharo, Jean-Claude; Bastard, Emilie; Franceschi, Frédéric; Habib, Gilbert; Jego, Christophe; Peyrouse, Eric; Prevot, Sebastien; Saint-Joseph, Hôpital; Bremondy, Michel; Faure, Jacques; Ferracci, Ange; Lefevre, Jean; Pisapia, Andre; Davy, Jean-Marc; Cransac, Frederic; Cung, Tien Tri; Georger, Frederic; Pasquie, Jean-Luc; Raczka, Franck; Sportouch-Dukhan, Catherine; Sadoul, Nicolas; Blangy, Hugues; Bruntz, Jean-François; Freysz, Luc; Groben, Laurent; Huttin, Olivier; Bammert, Antoine; Burban, Marc; Cebron, Jean-Pierre; Gras, Daniel; Frank, Robert; Duthoit, Guillaume; Hidden-Lucet, Françoise; Himbert, Caroline; Isnard, Richard; Lacotte, Jérôme; Pousset, Françoise; Zerah, Thierry; Leclercq, Christophe; Bellouin, Annaïk; Crocq, Christophe; Deplace, Christian; Donal, Erwan; Hamon, Cécile; Mabo, Philippe; Romain, Olivier; Solnon, Aude; Frederic, Anselme; Bauer, Fabrice; Bernard, Mathieu; Godin, Benedicte; Kurtz, Baptiste; Savoure, Arnaud; Copie, Xavier; Lascault, Gilles; Paziaud, Olivier; Piot, Olivier; Touche, Thierry; Delay, Toulouse Marc; Chilon, Talia; Detis, Nicolas; Duparc, Alexandre; Hebrard, Aurélien; Massabuau, Pierre; Maury, Philippe; Mondoly, Pierre; Rumeau, Philippe; Pasteur, Clinique; Boveda, Serge; Adrover, Laurence; Combes, Nicolas; Deplagne, Antoine; Marco-Baertich, Isabelle; Fondard, Olivier; Martínez, Juan Gabriel; Ibañez Criado, José Luis; Ortuño, Diego; Mont, Lluis; Berruezo, Antonio; Eduard, Belu; Martín, Ana; Merschon, Franco M.; Sitges, Marta; Tolosana, José María; Vidal, Bárbara; Hebron, H. Valle; i Mitjans, Angel Moya; Rodriguez, Oscar Alcalde; Rodriguez Palomares, José Fernando; Rivas, Nuria; Teixidó, Gisela; de Hierro, H. Puerta; Lozano, Ignacio Fernández; Ruiz Bautista, Maria Lorena; Castro, Victor; Cavero, Miguel Angel; Gutierrez, Carlos; Ros, Natalia; de la Victoria, H. Virgen; Alzueta Rodriguez, Francisco Javier; Cabrera, Fernando; Cordero, Alberto Barrera; Peña, José Luis; de Valme Sevilla, H.; Gonzáles, Juan Lealdel Ojo; Garcia Medina, Mª Dolores; Jiménez, Ricardo Pavón; Villagomez, David; de la Salud Toledo, H. Virgen; Castellanos Martinez, Eduardo; Alcalá, Juan; Maicas, Carolina; Arias Palomares, Miguel Angel; Puchol, Alberto; Valencia, H. La Fé; OscaAsensi, Joaquim; Carmona, Anastasio Quesada; De Carranza, Mª José Sancho-Tello; De Ros, José Olagüe; Pareja, Enrique Castro; Pérez, Oscar Cano; Saez, Ana Osa; Hortega, H. Rio; Guilarte, Benito Herreros; Muñoz San Jose, Juan Francisco; Pérez Sanz, Teresa Myriam; Logeart, Damien; Gil, Maria Lopez; Leclercq, Christophe; Lozano, Ignacio Fernandez; de Hierro, H. Puerta; Derumeaux, Genevieve

    2016-01-01

    Abstract Aims Cardiac resynchronization therapy (CRT) is a recommended treatment of heart failure (HF) patients with depressed left ventricular ejection fraction and wide QRS. The optimal right ventricular (RV) lead position being a matter of debate, we sought to examine whether RV septal (RVS) pacing was not inferior to RV apical (RVA) pacing on left ventricular reverse remodelling in patients receiving a CRT-defibrillator. Methods and results Patients (n = 263, age = 63.4 ± 9.5 years) were randomly assigned in a 1:1 ratio to RVS (n = 131) vs. RVA (n = 132) pacing. Left ventricular end-systolic volume (LVESV) reduction between baseline and 6 months was not different between the two groups (−25.3 ± 39.4 mL in RVS group vs. −29.3 ± 44.5 mL in RVA group, P = 0.79). Right ventricular septal pacing was not non-inferior (primary endpoint) to RVA pacing with regard to LVESV reduction (average difference = −4.06 mL; P = 0.006 with a −20 mL non-inferiority margin). The percentage of ‘echo-responders’ defined by LVESV reduction >15% between baseline and 6 months was similar in both groups (50%) with no difference in the time to first HF hospitalization or death (P = 0.532). Procedural or device-related serious adverse events occurred in 68 patients (RVS = 37) with no difference between the two groups (P = 0.401). Conclusion This study demonstrates that septal RV pacing in CRT is non-inferior to apical RV pacing for LV reverse remodelling at 6 months with no difference in the clinical outcome. No recommendation for optimal RV lead position can hence be drawn from this study. ClinicalTrials. gov number NCT 00833352. PMID:26374852

  12. Determining the risks of magnetic resonance imaging at 1.5 tesla for patients with pacemakers and implantable cardioverter defibrillators.

    Science.gov (United States)

    Cohen, Jennifer D; Costa, Heather S; Russo, Robert J

    2012-12-01

    Conventional pacemaker and implantable cardioverter-defibrillator product labeling currently cautions against exposure to magnetic resonance imaging (MRI). However, there is a growing clinical need for MRI, without an acceptable alternative imaging modality in many patients with cardiac devices. The purpose of this study was to determine the risk of MRI at 1.5 T for patients with cardiac devices by measuring the frequency of device failures and clinically relevant device parameter changes. Data from a single-center retrospective review of 109 patients with pacemakers and implantable cardioverter-defibrillators (the MRI group) who underwent 125 clinically indicated MRI studies were compared to data from a prospective cohort of 50 patients with cardiac devices who did not undergo MRI (the control group). In the MRI group, there were no deaths, device failures requiring generator or lead replacement, induced arrhythmias, losses of capture, or electrical reset episodes. Decreases in battery voltage of ≥0.04 V occurred in 4%, pacing threshold increases of ≥0.5 V in 3%, and pacing lead impedance changes of ≥50 Ω in 6%. Although there were statistically significant differences between the MRI and control groups for the mean change in pacing lead impedance (-6.2 ± 23.9 vs 3.0 ± 22.1 Ω) and left ventricular pacing threshold (-0.1 ± 0.3 vs 0.1 ± 0.2 V), these differences were not clinically important. In conclusion, MRI in patients with cardiac devices resulted in no device or lead failures. A small number of clinically relevant changes in device parameter measurements were noted. However, these changes were similar to those in a control group of patients who did not undergo MRI. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. A case of delayed cardiac perforation of active ventricular lead

    Directory of Open Access Journals (Sweden)

    Hangyuan Guo

    2011-12-01

    Full Text Available A 65-year-old man was admitted as for one month of repetitive dizziness and one episode of syncope. Electrocardiogram showed sinus bradycardia and his Holter monitoring also showed sinus bradycardia with sinus arrest, sino-atrial block and a longest pause of 4.3 s. Then sick sinus syndrome and Adam-Stokes syndrome were diagnosed. Then a dual chamber pacemaker (Medtronic SDR303 was implanted and the parameters were normal by detection. The patient was discharged 1 week later with suture removed. Then 1.5 month late the patient was presented to hospital once again for sudden onset of chest pain with exacerbation after taking deep breath. Pacemaker programming showed both pacing and sensing abnormality with threshold of?5.0V and resistance of 1200?. Lead perforation was revealed by chest X-ray and confirmed by echocardiogram. Considering the fact that there was high risk to remove ventricular lead, spiral tip of previous ventricular lead was withdrew followed by implantation of a new ventricular active lead to the septum. Previous ventricular lead was maintained. As we know that the complications of lead perforation in the clinic was rare. Here we discuss the clinical management and the possible reasons for cardiac perforation of active ventricular lead.

  14. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  15. Diaphragm pacing improves sleep in patients with amyotrophic lateral sclerosis.

    Science.gov (United States)

    Gonzalez-Bermejo, Jesus; Morélot-Panzini, Capucine; Salachas, François; Redolfi, Stefania; Straus, Christian; Becquemin, Marie-Hélène; Arnulf, Isabelle; Pradat, Pierre-François; Bruneteau, Gaëlle; Ignagni, Anthony R; Diop, Moustapha; Onders, Raymond; Nelson, Teresa; Menegaux, Fabrice; Meininger, Vincent; Similowski, Thomas

    2012-01-01

    In amyotrophic lateral sclerosis (ALS) patients, respiratory insufficiency is a major burden. Diaphragm conditioning by electrical stimulation could interfere with lung function decline by promoting the development of type 1 muscle fibres. We describe an ancillary study to a prospective, non-randomized trial (NCT00420719) assessing the effects of diaphragm pacing on forced vital capacity (FVC). Sleep-related disturbances being early clues to diaphragmatic dysfunction, we postulated that they would provide a sensitive marker. Stimulators were implanted laparoscopically in the diaphragm close to the phrenic motor point in 18 ALS patients for daily conditioning. ALS functioning score (ALSFRS), FVC, sniff nasal inspiratory pressure (SNIP), and polysomnographic recordings (PSG, performed with the stimulator turned off) were assessed before implantation and after four months of conditioning (n = 14). Sleep efficiency improved (69 ± 15% to 75 ± 11%, p = 0.0394) with fewer arousals and micro-arousals. This occurred against a background of deterioration as ALSFRS-R, FVC, and SNIP declined. There was, however, no change in NIV status or the ALSFRS respiratory subscore, and the FVC decline was mostly due to impaired expiration. Supporting a better diaphragm function, apnoeas and hypopnoeas during REM sleep decreased. In conclusion, in these severe patients not expected to experience spontaneous improvements, diaphragm conditioning improved sleep and there were hints at diaphragm function changes.

  16. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    Underlying ion-beam modification of surfaces is the more basic subject of particle-surface interaction. The ideas can be grouped into forward and backward features, i.e. those affecting the interior of the target and those leading to particle expulsion. Forward effects include the stopping of the incident particles and the deposition of energy, both governed by integral equations which are easily set up but difficult to solve. Closely related is recoil implantation where emphasis is placed not on the stopping of the incident particles but on their interaction with target atoms with resulting implantation of these atoms. Backward effects, all of which are denoted as sputtering, are in general either of collisional, thermal, electronic, or exfoliational origin. (Auth.)

  17. Ion implantation for semiconductors

    International Nuclear Information System (INIS)

    Grey-Morgan, T.

    1995-01-01

    Full text: Over the past two decades, thousands of particle accelerators have been used to implant foreign atoms like boron, phosphorus and arsenic into silicon crystal wafers to produce special embedded layers for manufacturing semiconductor devices. Depending on the device required, the atomic species, the depth of implant and doping levels are the main parameters for the implantation process; the selection and parameter control is totally automated. The depth of the implant, usually less than 1 micron, is determined by the ion energy, which can be varied between 2 and 600 keV. The ion beam is extracted from a Freeman or Bernas type ion source and accelerated to 60 keV before mass analysis. For higher beam energies postacceleration is applied up to 200 keV and even higher energies can be achieved by mass selecting multiplycharged ions, but with a corresponding reduction in beam output. Depending on the device to be manufactured, doping levels can range from 10 10 to 10 15 atoms/cm 2 and are controlled by implanter beam currents in the range up to 30mA; continuous process monitoring ensures uniformity across the wafer of better than 1 % . As semiconductor devices get smaller, additional sophistication is required in the design of the implanter. The silicon wafers charge electrically during implantation and this charge must be dissipated continuously to reduce the electrical stress in the device and avoid destructive electrical breakdown. Electron flood guns produce low energy electrons (below 10 electronvolts) to neutralize positive charge buildup and implanter design must ensure minimum contamination by other isotopic species and ensure low internal sputter rates. The pace of technology in the semiconductor industry is such that implanters are being built now for 256 Megabit circuits but which are only likely to be widely available five years from now. Several specialist companies manufacture implanter systems, each costing around US$5 million, depending on the

  18. Pacing in Swimming: A Systematic Review.

    Science.gov (United States)

    McGibbon, Katie E; Pyne, D B; Shephard, M E; Thompson, K G

    2018-03-20

    Pacing strategy, or how energy is distributed during exercise, can substantially impact athletic performance and is considered crucial for optimal performance in many sports. This is particularly true in swimming given the highly resistive properties of water and low mechanical efficiency of the swimming action. The aim of this systematic review was to determine the pacing strategies utilised by competitive swimmers in competition and their reproducibility, and to examine the impact of different pacing strategies on kinematic, metabolic and performance variables. This will provide valuable and practical information to coaches and sports science practitioners. The databases Web of Science, Scopus, SPORTDiscus and PubMed were searched for published articles up to 1 August 2017. A total of 23 studies examining pool-based swimming competitions or experimental trials in English-language and peer-reviewed journals were included in this review. In short- and middle-distance swimming events maintenance of swimming velocity is critical, whereas in long-distance events a low lap-to-lap variability and the ability to produce an end spurt in the final lap(s) are key. The most effective strategy in the individual medley (IM) is to conserve energy during the butterfly leg to optimise performance in subsequent legs. The pacing profiles of senior swimmers remain relatively stable irrespective of opponents, competition stage or type, and performance time. Implementing event-specific pacing strategies should benefit the performance of competitive swimmers. Given differences between swimmers, there is a need for greater individualisation when considering pacing strategy selection across distances and strokes.

  19. Does reducing unnecessary right ventricular pacing improve sympathetic activity and innervation of heart in sinus node disease patients? MVP and SafeR study.

    Science.gov (United States)

    Miyamoto, Mihoko; Kimura, Yuichiro; Hosoda, Junya; Matsumoto, Katsumi; Matsushita, Kohei; Ishikawa, Toshiyuki; Umemura, Satoshi

    2012-01-01

    Ventricular desynchronization imposed by ventricular pacing causes regional disturbances of adrenergic innervation in the left ventricular myocardium and increases the risk of heart failure and atrial fibrillation (AF) in patients with sinus node disease (SND). As a result, decreased iodine-123 metaiodobenzylguanidine (I-(123 )MIBG) uptake occurs in patients with an implanted permanent pacemaker. Fourteen SND patients with an implanted pacemaker equipped with an algorithm for reducing unnecessary right ventricular pacing (RURVP) were enrolled. Pacemakers were programmed to RURVP mode for the first 12 weeks, and then reprogrammed to DDD for the last 12 weeks. At the end of each mode, data on cumulative percent ventricular pacing (%Vp), atrial high rate episodes (%AHR), I-(123 )MIBG myocardial scintigraphy, brain natriuretic peptide (BNP), human atrial natriuretic peptide (hANP), and myocardial damage indices typified by troponin T and C-reactive protein (CRP) were collected. %Vp was lower in RURVP than in DDD (0.2% versus 95.7%, P = 0.00098). BNP, hANP, troponin T, and CRP did not differ significantly between the pacing modes. However, I-(123 )MIBG findings of patients with full ventricular pacing in DDD improved in RURVP. In contrast, among patients without full ventricular pacing in DDD, their I-(123 )MIBG findings did not differ significantly between the pacing modes. In SND patients with normal cardiac function and intact atrioventricular conduction, the reduction of %Vp in RURVP was due to the reduction of ineffective pacing and fusion pacing in DDD. Therefore, these 2 types of pacing do not affect cardiac pump function.

  20. Sequential biventricular pacing improves regional contractility, longitudinal function and dyssynchrony in patients with heart failure and prolonged QRS

    Directory of Open Access Journals (Sweden)

    Ring Margareta

    2010-04-01

    Full Text Available Abstract Aims Biventricular pacing (BiP is an effective treatment in systolic heart failure (HF patients with prolonged QRS. However, approximately 35% of the patients receiving BiP are classified as non-responders. The aim of this study is to evaluate the acute effects of VV-optimization on systolic heart function. Methods Twenty-one HF patients aged 72 (46-88 years, QRS 154 (120-190 ms, were studied with echocardiography, Tissue Doppler Imaging (TDI and 3D-echo the first day after receiving a BiP device. TDI was performed; during simultaneous pacing (LV-lead pacing 4 ms before the RV-lead and during sequential pacing (LV 20 and 40 ms before RV and RV 20 and 40 ms before LV-lead pacing. Systolic heart function was studied by tissue tracking (TT for longitudinal function and systolic maximal velocity (SMV for regional contractility and signs of dyssynchrony assessed by time-delays standard deviation of aortic valve opening to SMV, AVO-SMV/SD and tissue synchronization imaging (TSI. Results The TT mean value preoperatively was 4,2 ± 1,5 and increased at simultaneous pacing to 5,0 ± 1,2 mm (p Conclusions VV-optimization in the acute phase improves systolic heart function more than simultaneous BiP pacing. Long-term effects should be evaluated in prospective randomized trials.

  1. How do we perceive activity pacing in rheumatology care?

    DEFF Research Database (Denmark)

    Cuperus, N.; Vliet Vlieland, T.; Brodin, N.

    2015-01-01

    goals of activity pacing, behaviours of activity pacing (the actions people take to meet the goal of activity pacing), strategies to change behaviour in activity pacing (for example goal setting) and contextual factors that should be acknowledged when instructing activity pacing. Besides, topics......-management programs. However, despite its wide endorsement in clinical practice, to date activity pacing is still a poorly understood concept. Objectives: To achieve consensus by means of an international Delphi exercise on the most important aspects of activity pacing as an intervention within non...... for future research on activity pacing were formulated and prioritized. Results: Of the 60 panelists, nearly two third (63%) completed all four Delphi rounds. The panel prioritized 9 goals, 11 behaviours, 9 strategies to change behaviour and 10 contextual factors of activity pacing. These items were...

  2. Self-Paced Instruction: Hello, Education

    Science.gov (United States)

    Leuba, Richard J.; Flammer, Gordon H.

    1975-01-01

    Answers criticisms of self-paced instruction (SPI) by citing advantages of SPI over lecture methods. Concludes that criticisms of SPI are useful since they indicate in which areas further research should be conducted to improve this method of instruction. (MLH)

  3. The Platform-Aware Compilation Environment (PACE)

    Science.gov (United States)

    2012-09-01

    The PACE Project provided full or partial support for the following graduate students: 1. Raj Barik (Rice) 2. Thomas Barr (Rice) 3...University, Houston, TX, Technical Report CS TR11-03, October 20, 2011. [7] Rajkishore Barik , Jisheng Zhao, and Vivek Sarkar, "Efficient Selection

  4. The pace and shape of ageing

    DEFF Research Database (Denmark)

    Baudisch, Annette

    2011-01-01

    exhibits negligible ageing - contrary to the commonly held view that long-lived species are good candidates for negligible ageing. 5.Analysis of species in pace-shape space provides a tool to identify key determinants of the evolution of ageing for species across the tree of life....

  5. Potenzielle Einflussfaktoren auf Pacing im ausdauersportlichen Wettkampf

    NARCIS (Netherlands)

    Thiel, C.; de Koning, J.J.; Foster, C.

    2015-01-01

    In competitive endurance sport, athletes permanently regulate their performance to achieve the best result without threatening organismic integrity. This conscious and subconscious allocation of energy reserves in relation to an endpoint is termed pacing and depends on sport-specific experience as

  6. Laser-assisted lead extraction: the European experience.

    Science.gov (United States)

    Kennergren, C; Bucknall, C A; Butter, C; Charles, R; Fuhrer, J; Grosfeld, M; Tavernier, R; Morgado, T B; Mortensen, P; Paul, V; Richter, P; Schwartz, T; Wellens, F

    2007-08-01

    The aim of this study is to investigate the safety and effectiveness of Excimer laser-assisted lead extraction in Europe. The final European multi-centre study experience is presented. The Excimer is a cool cutting laser (50 degrees C) with a wavelength of 308 nm. The energy is emitted from the tip of a flexible sheath and is absorbed by proteins and lipids, 64% of the energy is absorbed at a tissue depth of 0.06 mm. The sheath is positioned over the lead, and the fibrosis surrounding the lead is vaporized while advancing the sheath without damaging other leads. From August 1996 to March 2001, 383 leads (170 atrial, 213 ventricular) in 292 patients (mean age 61.6 years, range 13-96) were extracted at 14 European centres. Mean implantation time was 74 months (3-358). Most frequent indications were pocket infection (26%), non-functional leads (21%), patient morbidity (21%), septicaemia or endocarditis (14%), erosion (5%), and lead interference (8%). Median extraction time was 15 min (1-300). Complete extraction was achieved in 90.9% of the leads and partial extraction in 3.4%. Extraction failed in 5.7% of the leads. Major complications = perforations caused 10/22 (3.4/5.7%) of the failures. Most partially extracted patients were considered clinically successful, as only minor lead parts without clinical significance were left. Femoral non-laser technique was used to remove 8/12 of the non-complication failures. The total complication rate, including five minor complications (1.7%), was 5.1%. No in-hospital mortality occurred. Pacing and implantable cardioverter-defibrillator leads can safely, effectively, and predictably be extracted. Open-heart extractions can be limited to special cases. The results indicate that the traditional policy of abandoning redundant leads, instead of removing them, may be obsolete in many patients.

  7. Magnetic resonance imaging at 1.5-T in patients with implantable cardioverter-defibrillators.

    Science.gov (United States)

    Naehle, Claas P; Strach, Katharina; Thomas, Daniel; Meyer, Carsten; Linhart, Markus; Bitaraf, Sascha; Litt, Harold; Schwab, Jörg Otto; Schild, Hans; Sommer, Torsten

    2009-08-04

    Our aim was to establish and evaluate a strategy for safe performance of magnetic resonance imaging (MRI) at 1.5-T in patients with implantable cardioverter-defibrillators (ICDs). Expanding indications for ICD placement and MRI becoming the imaging modality of choice for many indications has created a growing demand for MRI in ICD patients, which is still considered an absolute contraindication. Non-pacemaker-dependent ICD patients with a clinical need for MRI were included in the study. To minimize radiofrequency-related lead heating, the specific absorption rate was limited to 2 W/kg. ICDs were reprogrammed pre-MRI to avoid competitive pacing and potential pro-arrhythmia: 1) the lower rate limit was programmed as low as reasonably achievable; and 2) arrhythmia detection was programmed on, but therapy delivery was programmed off. Patients were monitored using electrocardiography and pulse oximetry. All ICDs were interrogated before and after the MRI examination and after 3 months, including measurement of pacing capture threshold, lead impedance, battery voltage, and serum troponin I. Eighteen ICD patients underwent a total of 18 MRI examinations at 1.5-T; all examinations were completed safely. All ICDs could be interrogated and reprogrammed normally post-MRI. No significant changes of pacing capture threshold, lead impedance, and serum troponin I were observed. Battery voltage decreased significantly from pre- to post-MRI. In 2 MRI examinations, oversensing of radiofrequency noise as ventricular fibrillation occurred. However, no attempt at therapy delivery was made. MRI of non-pacemaker-dependent ICD patients can be performed with an acceptable risk/benefit ratio under controlled conditions by taking both MRI- and pacemaker-related precautions. (Implantable Cardioverter Defibrillators and Magnetic Resonance Imaging of the Heart at 1.5-Tesla; NCT00356239).

  8. The Jervell and Lange-Nielsen syndrome; atrial pacing combined with ß-blocker therapy, a favorable approach in young high-risk patients with long QT syndrome?

    Science.gov (United States)

    Früh, Andreas; Siem, Geir; Holmström, Henrik; Døhlen, Gaute; Haugaa, Kristina H

    2016-11-01

    Patients with Jervell and Lange-Nielsen syndrome (JLNS) exhibit severe phenotypes that are characterized by congenital deafness, very long QT intervals, and high risk of life-threatening arrhythmias. Current treatment strategies include high doses of beta-blocker medication, left cardiac sympathetic denervation, and ICD placement, which is challenging in young children. The purpose of this study was to evaluate the safety and effect of pacing in addition to beta-blocker treatment in children with JLNS. All genetically confirmed patients with JLNS born since 1999 in Norway were included in the study. Data on history of long QT syndrome-related symptoms, QT interval, and beta-blocker and pacemaker treatment were recorded. A total of 9 patients with QT intervals ranging from 510 to 660 ms were identified. Eight patients developed long QT syndrome-related symptoms, and 1 patient died before diagnosis. The survivors received beta-blocker medication. Seven patients also received a pacemaker; 1 had a ventricular lead and 6 had atrial leads. The patient with the ventricular lead died during follow-up. The 6 patients with atrial leads survived without events at a mean follow-up of 6.9 years after pacemaker implantation. Two patients received prophylactic upgrade to a 2-chamber ICD. No arrhythmic events occurred in 6 very young JLNS patients who received atrial pacing in combination with increased doses of beta-blockers during 7-year follow-up. If confirmed in additional patients, this treatment strategy may prevent life-threatening arrhythmias in this high-risk patient group and may act as a bridge to insertion of a 2-chamber ICD when left cardiac sympathetic denervation is not available. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Occurrence of phrenic nerve stimulation in cardiac resynchronization therapy patients: the role of left ventricular lead type and placement site.

    Science.gov (United States)

    Biffi, Mauro; Exner, Derek V; Crossley, George H; Ramza, Brian; Coutu, Benoit; Tomassoni, Gery; Kranig, Wolfgang; Li, Shelby; Kristiansen, Nina; Voss, Frederik

    2013-01-01

    Unwanted phrenic nerve stimulation (PNS) has been reported in ∼1 in 4 patients undergoing left ventricular (LV) pacing. The occurrence of PNS over mid-term follow-up and the significance of PNS are less certain. Data from 1307 patients enrolled in pre-market studies of LV leads manufactured by Medtronic (models 4193 and 4195 unipolar, 4194, 4196, 4296, and 4396 bipolar) were pooled. Left ventricular lead location was recorded at implant using a common classification scheme. Phrenic nerve stimulation symptoms were either spontaneously reported or identified at scheduled follow-up visits. A PNS-related complication was defined as PNS resulting in invasive intervention or the termination of LV pacing. Average follow-up was 14.9 months (range 0.0-46.6). Phrenic nerve stimulation symptoms occurred in 169 patients (12.9%). Phrenic nerve stimulation-related complications occurred in 21 of 1307 patients (1.6%); 16 of 738 (2.2%) in the unipolar lead studies, and 5 of 569 (0.9%) in the bipolar lead studies (P = 0.08). Phrenic nerve stimulation was more frequent at middle-lateral/posterior, and apical LV sites (139/1010) vs. basal-posterior/lateral/anterior, and middle-anterior sites (20/297; P= 0.01). As compared with an anterior LV lead position, a lateral LV pacing site was associated with over a four-fold higher risk of PNS (P= 0.005) and an apical LV pacing site was associated with over six-fold higher risk of PNS (P= 0.001). Phrenic nerve stimulation occurred in 13% of patients undergoing LV lead placement and was more common at mid-lateral/posterior, and LV apical sites. Most cases (123/139; 88%) of PNS were mitigated via electrical reprogramming, without the need for invasive intervention.

  10. Pace of work stabilising, but not in all sectors

    NARCIS (Netherlands)

    Houtman, I.L.D.

    2003-01-01

    The Netherlands had the highest level of work pace in Europe but this position has levelled off in the last five years. There appears to be a general trend towards a decline in work pace. However, different sectors show varying trends, with work pace on the rise again in the education, health and

  11. Visual aided pacing in respiratory maneuvers

    Energy Technology Data Exchange (ETDEWEB)

    Rambaudi, L R [Laboratorio de Biofisica y Fisiologia ' Antonio Sadi Frumento' (Argentina); Rossi, E [Catedra de Bioingenieria II (Argentina); Mantaras, M C [Catedra de Bioingenieria II (Argentina); Perrone, M S [Laboratorio de Biofisica y Fisiologia ' Antonio Sadi Frumento' (Argentina); Siri, L Nicola [Catedra de Bioingenieria II (Argentina)

    2007-11-15

    A visual aid to pace self-controlled respiratory cycles in humans is presented. Respiratory manoeuvres need to be accomplished in several clinic and research procedures, among others, the studies on Heart Rate Variability. Free running respiration turns to be difficult to correlate with other physiologic variables. Because of this fact, voluntary self-control is asked from the individuals under study. Currently, an acoustic metronome is used to pace respiratory frequency, its main limitation being the impossibility to induce predetermined timing in the stages within the respiratory cycle. In the present work, visual driven self-control was provided, with separate timing for the four stages of a normal respiratory cycle. This visual metronome (ViMet) was based on a microcontroller which power-ON and -OFF an eight-LED bar, in a four-stage respiratory cycle time series handset by the operator. The precise timing is also exhibited on an alphanumeric display.

  12. Visual aided pacing in respiratory maneuvers

    International Nuclear Information System (INIS)

    Rambaudi, L R; Rossi, E; Mantaras, M C; Perrone, M S; Siri, L Nicola

    2007-01-01

    A visual aid to pace self-controlled respiratory cycles in humans is presented. Respiratory manoeuvres need to be accomplished in several clinic and research procedures, among others, the studies on Heart Rate Variability. Free running respiration turns to be difficult to correlate with other physiologic variables. Because of this fact, voluntary self-control is asked from the individuals under study. Currently, an acoustic metronome is used to pace respiratory frequency, its main limitation being the impossibility to induce predetermined timing in the stages within the respiratory cycle. In the present work, visual driven self-control was provided, with separate timing for the four stages of a normal respiratory cycle. This visual metronome (ViMet) was based on a microcontroller which power-ON and -OFF an eight-LED bar, in a four-stage respiratory cycle time series handset by the operator. The precise timing is also exhibited on an alphanumeric display

  13. Echocardiographic estimation of acute haemodynamic response during optimization of multisite pace-maker using different pacing modalities and atrioventricular delays

    Directory of Open Access Journals (Sweden)

    Šalinger-Martinović Sonja

    2009-01-01

    Full Text Available Background/Aim. Cardiac resynchronization therapy (CRT improves ventricular dyssynchrony and is associated with an improvement in symptoms, quality of life and prognosis in patients with severe heart failure and intraventricular conduction delay. Different pacing modalities produce variable activation patterns and may be a cause of different haemodynamic changes. The aim of our study was to investigate acute haemodynamic changes with different CRT configurations during optimization procedure. Methods. This study included 30 patients with severe left ventricular systolic dysfunction and left bundle branch block with wide QRS (EF 24.33 ± 3.7%, QRS 159 ± 17.3 ms, New York Heart Association III/IV 25/5 with implanted CRT device. The whole group of patients had severe mitral regurgitation in order to measure dP/dt. After implantation and before discharge all the patients underwent optimization procedure guided by Doppler echocardiography. Left and right ventricular pre-ejection intervals (LVPEI and RVPEI, interventricular mechanical delay (IVD and the maximal rate of ventricular pressure rise during early systole (max dP/dt were measured during left and biventricular pacing with three different atrioventricular (AV delays. Results. After CRT device optimization, optimal AV delay and CRT mode were defined. Left ventricular pre-ejection intervals changed from 170.5 ± 24.6 to 145.9 ± 9.5 (p < 0.001, RVPEI from 102.4 ± 15.9 to 119.8 ± 10.9 (p < 0.001, IVD from 68.1 ± 18.3 to 26.5 ± 8.2 (p < 0.001 and dP/dt from 524.2 ± 67 to 678.2 ± 88.5 (p < 0.01. Conclusion. In patients receiving CRT echocardiographic assessment of the acute haemodynamic response to CRT is a useful tool in optimization procedure. The variability of Doppler parameters with different CRT modalities emphasizes the necessity of individualized approach in optimization procedure.

  14. Pacing, packing and sex-based differences in Olympic and IAAF World Championship marathons.

    Science.gov (United States)

    Hanley, Brian

    2016-09-01

    The aim of this study was to describe pacing profiles and packing behaviours of athletes in Olympic and World Championship marathons. Finishing and split times were collated for 673 men and 549 women across nine competitions. The mean speeds for each intermediate 5 km and end 2.2 km segments were calculated. Medallists of both sexes maintained even-paced running from 10 km onwards whereas slower finishers dropped off the lead pack at approximately half-distance. Athletes who ran with the same opponents throughout slowed the least in the second half (P tactics adopted and design training programmes accordingly.

  15. Effects of elevated ambient temperature on embryo implantation in rats

    African Journals Online (AJOL)

    Yomi

    2012-03-22

    Mar 22, 2012 ... ambient temperature leads to a delayed implantation and reduced number of implantation sites in. Sprague ... rates decrease after exposure to stress. One of the ..... implantation initiation time, support the previous findings.

  16. Long pacing pulses reduce phrenic nerve stimulation in left ventricular pacing.

    Science.gov (United States)

    Hjortshøj, Søren; Heath, Finn; Haugland, Morten; Eschen, Ole; Thøgersen, Anna Margrethe; Riahi, Sam; Toft, Egon; Struijk, Johannes Jan

    2014-05-01

    Phrenic nerve stimulation is a major obstacle in cardiac resynchronization therapy (CRT). Activation characteristics of the heart and phrenic nerve are different with higher chronaxie for the heart. Therefore, longer pulse durations could be beneficial in preventing phrenic nerve stimulation during CRT due to a decreased threshold for the heart compared with the phrenic nerve. We investigated if long pulse durations decreased left ventricular (LV) thresholds relatively to phrenic nerve thresholds in humans. Eleven patients, with indication for CRT and phrenic nerve stimulation at the intended pacing site, underwent determination of thresholds for the heart and phrenic nerve at different pulse durations (0.3-2.9 milliseconds). The resulting strength duration curves were analyzed by determining chronaxie and rheobase. Comparisons for those parameters were made between the heart and phrenic nerve, and between the models of Weiss and Lapicque as well. In 9 of 11 cases, the thresholds decreased faster for the LV than for the phrenic nerve with increasing pulse duration. In 3 cases, the thresholds changed from unfavorable for LV stimulation to more than a factor 2 in favor of the LV. The greatest change occurred for pulse durations up to 1.5 milliseconds. The chronaxie of the heart was significantly higher than the chronaxie of the phrenic nerve (0.47 milliseconds vs. 0.22 milliseconds [P = 0.029, Lapicque] and 0.79 milliseconds vs. 0.27 milliseconds [P = 0.033, Weiss]). Long pulse durations lead to a decreased threshold of the heart relatively to the phrenic nerve and may prevent stimulation of the phrenic nerve in a clinical setting. © 2013 Wiley Periodicals, Inc.

  17. Special Problems Of Pacing In Children

    Directory of Open Access Journals (Sweden)

    Herwig Antretter

    2003-01-01

    Full Text Available The number of children suffering from congenital or acquired rhythm disorders, and therefore being pacemaker dependent, is very small. This is one of the reasons why a special hardware has never been developed for this cohort. Pacemaker implantation into children does not differ substantially from operations in adults. But there are several important points which have to be fulfilled in these small patients in order to guarantee a complication free function. As most of these children remain pacemaker dependent a lifetime, it is of tremendous importance to minimize all revisions regarding the implanted systems and to enable our small patients a high and therefore nearly normal quality of life. Pros and cons of different surgical approaches, implantation sites and the problem of growth after pacemaker implantation in children are considered.

  18. Effect of renal sympathetic denervation on atrial substrate remodeling in ambulatory canines with prolonged atrial pacing.

    Directory of Open Access Journals (Sweden)

    Xule Wang

    Full Text Available We have previously demonstrated that catheter-based renal sympathetic denervation (RSD could suppress atrial fibrillation (AF in canines with short-time rapid right atrial pacing (RAP. However, the role of renal denervation on atrial remodeling is unclear. The aim of the present study was to explore the long-term effect of RSD on the atrial remodeling during prolonged RAP. Twenty mongrel dogs were implanted with a high-frequency cardiac pacemaker with a transvenous lead inserted into the right atrial appendage. The dogs were divided into three groups: a sham-operated group (n = 6, the chronic RAP (CRAP group (n = 7, and the CRAP+RSD group (n = 7. In the CRAP+RSD group, a pacemaker was implanted 6 weeks after RSD was performed bilaterally for recovery. RAP was maintained for 5 weeks in CRAP group and CRAP+RSD group. The plasma levels of Angiotensin II and aldosterone were significantly increased in CRAP group compared with sham-operated group, but the increasing trend was inhibited in CRAP+RSD group compared with CRAP group (P<0.05. Similarly, RSD suppressed the increasing trend that prolonged RAP produced in the left atrial levels of ANP, TNF-α and IL-6. Compared with the sham-operated group, the CRAP group had significantly increased levels of caspase-3, bax and Cx40 whereas the level of Bcl-2 decreased (P<0.05. RSD markedly reduced the upregulation of caspase-3, bax and Cx40 and the downregulation of Bcl-2 expression compared with the CRAP group (P<0.05. Picric acid-sirius red staining study suggested that RSD could markedly alleviate the lesion degree of cardic fibrosis induced by CRAP (P<0.05. Immunohistochemistry results showed that the densities of TH- and GAP43- positive nerves were significantly elevated in the CRAP group compared with the sham-operated group, while RSD operation signicantly inhibited the these changes produced by CRAP. These findings suggest that renal denervation could suppress the atrial remodeling after

  19. Autoinflation Leading to Failure of Two-Piece Ambicor Implantable Penile Prosthesis: An Outcome from a Methodical Treatment of Recalcitrant Stuttering Priapism

    Directory of Open Access Journals (Sweden)

    R. Charles Welliver

    2014-01-01

    Full Text Available Introduction. We present the case of a patient who received a two-piece Ambicor penile prosthesis for idiopathic recurrent “stuttering” priapism refractory to other treatment options. The patient returned unable to deflate the device due to an interesting anatomically induced mechanical failure. Aims. To describe the method and findings of this inflatable prosthesis failure. Results. Prosthesis failure occurred due to restrictive corporal diameter and the unique characteristics of fluid reservoir location in the two-piece inflatable prosthesis. The patient was successfully converted to a semirigid prosthesis with resolution of the pain that was due to his prosthesis autoinflation. Conclusion. Stuttering priapism remains a challenging clinical problem. Penile implantation is a reasonable long-term solution in a patient refractory to less invasive options. In patients with fibrotic corpora, a malleable device should be considered (at least temporarily if unable to dilate comfortably to 13 mm.

  20. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  1. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  2. Cochlear Implants

    Science.gov (United States)

    ... implant, including: • How long a person has been deaf, •The number of surviving auditory nerve fibers, and • ... Implant, Severe Sensoryneurial Hearing Loss Get Involved Professional Development Practice Management ENT Careers Marketplace Privacy Policy Terms ...

  3. Occlusal considerations for dental implant restorations.

    Science.gov (United States)

    Bergmann, Ranier H

    2014-01-01

    When placed, dental implants are put into an ever-changing oral environment in which teeth can continue to migrate. Yet, the implants themselves are ankylosed. This can lead to occlusal instability. Teeth may continue to erupt, leaving the implants in infraocclusion. Teeth may move mesially away from an implant, requiring modification to close an open contact point. Friction in the connection between teeth and implants can lead to intrusion of teeth and damage to the periodontal attachment apparatus. Implant occlusion with shallow incisal guidance minimizes lateral and tipping forces. Cross-arch stabilization allows the best distribution of occlusal forces. The choice of restorative materials influences long-term occlusal stability.

  4. A cardiac implantable device infection by Raoultella planticola in an immunocompromized patient.

    Science.gov (United States)

    Adjodah, Chandra; D'Ivernois, Chistophe; Leyssene, David; Berneau, Jean-Baptiste; Hemery, Yann

    2017-02-01

    Introduction. Infection of cardiac implantable electronic devices is a severe condition associated with high mortality, particularly in patients who are dependent upon heart-pacing devices. Staphylococci are found in 70 % of reported cases. Case presentation. We report the case of a cardiac-pacemaker infection in a 79-year-old man, cumulating a history of rheumatoid arthritis treated by corticosteroids and methotrexate by a recently identified micro-organism: Raoultella planticola . He presented local signs of infection on his VVI pacemaker implantation site and underwent urgent pocket device replacement under cefamandole antibioprophylaxis. On incision thick pus oozed out. It was necessary to perform a complete hardware extraction comprising the pulse generator and the ancient lead. Pus was inoculated into aerobic and anaerobic culture vials and Gram staining unveiled Gram-negative rods. Microbiology analysis identified the organism as R. planticola. A new pacing device was inserted on the contrlateral pectoral region. Ciprofloxacin enabled full recovery. A literature review concerning this pathogen revealed that it is involved in severe infections such as bloodstream infections, peritonitis, cellulitis, pneumonia and lung abscesses, and urinary tract infections. In these case reports, underlying co-morbidities were identified such as solid active neoplasia, recent chemotherapy, corticosteroids, solid-organ-recipient patients and recent open surgery. Conclusion. R. planticola is a serious emerging pathogen and contributes to the burden of various infectious conditions. Its pathogenicity and occurrence should be known by clinicians and a high level of awareness is necessary to precisely identify it provide the correct antibiotic regimen.

  5. An algorithmic programming approach for back pain symptoms in failed back surgery syndrome using spinal cord stimulation with a multicolumn surgically implanted epidural lead: a multicenter international prospective study.

    Science.gov (United States)

    Rigoard, Philippe; Jacques, Line; Delmotte, Alexandre; Poon, Katherine; Munson, Russell; Monlezun, Olivier; Roulaud, Manuel; Prevost, Audrey; Guetarni, Farid; Bataille, Benoit; Kumar, Krishna

    2015-03-01

    Many studies have demonstrated the efficacy and the medical/economic value of epidural spinal cord stimulation for the treatment of "failed back surgery syndrome" (FBSS). However, the back pain component of FBSS has been recalcitrant. Recent clinical trials have suggested that multicolumn surgically implanted leads combined with enhanced programming capabilities in the newer implantable pulse generators demonstrate the ability to treat the back pain component of FBSS. The objective of our present international multicentre study is to prospectively evaluate these findings in a larger population. We conducted a prospective, nonrandomized, observational study on 76 patients with refractory FBSS, consecutively implanted with multicolumn spinal cord stimulation (SCS) between 2008 and 2011 in three neurosurgical pain management centers (Poitiers, France; Montréal, Canada; and Regina, Canada). The primary objective of this study was to prospectively analyze the effect of multicolumn lead programming on paresthesia coverage for the back pain region in these patients. The secondary objective was to assess the analgesic efficacy of this technique on the global and back pain components. Paresthesia could be induced in the lower extremities in the majority of patients with at least one of the configurations tested. Bilateral low back paresthesia was induced in 53.5% of patients, while unilateral low back paresthesia was induced in 78.9% of patients. Multicolumn configurations were statistically more effective than monocolumn configurations for all anatomic regions studied. At 6 months, 75.4% of patients receiving multicolumn stimulation (n = 57) obtained at least a 30% improvement of the back pain VAS score, while 42.1% of patients obtained at least a 50% improvement of the back pain VAS score. This study confirms the hypothesis that multicolumn SCS should be considered as an important tool in the treatment of radicular and axial pain in FBSS patients. The efficacy of this

  6. A Retrospective Analysis of Ruptured Breast Implants

    Directory of Open Access Journals (Sweden)

    Woo Yeol Baek

    2014-11-01

    Full Text Available BackgroundRupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants.MethodsWe performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone, duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management.ResultsForty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case, microfat graft (2 case, removal only (14 case, and follow-up loss (17 case.ConclusionsSaline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs.

  7. Video-assisted thoracoscopic implantation of a diaphragmatic pacemaker in a child with tetraplegia: indications, technique, and results

    Directory of Open Access Journals (Sweden)

    Darcy Ribeiro Pinto Filho

    2015-02-01

    Full Text Available We report the case of a child with tetraplegia after cervical trauma, who subsequently underwent diaphragmatic pacemaker implantation. We reviewed the major indications for diaphragmatic pacing and the types of devices employed. We highlight the unequivocal benefit of diaphragmatic pacing in the social and educational reintegration of individuals with tetraplegia.

  8. Optimal Implantable Cardioverter Defibrillator Programming.

    Science.gov (United States)

    Shah, Bindi K

    Optimal programming of implantable cardioverter defibrillators (ICDs) is essential to appropriately treat ventricular tachyarrhythmias and to avoid unnecessary and inappropriate shocks. There have been a series of large clinical trials evaluating tailored programming of ICDs. We reviewed the clinical trials evaluating ICD therapies and detection, and the consensus statement on ICD programming. In doing so, we found that prolonged ICD detection times, higher rate cutoffs, and antitachycardia pacing (ATP) programming decreases inappropriate and painful therapies in a primary prevention population. The use of supraventricular tachyarrhythmia discriminators can also decrease inappropriate shocks. Tailored ICD programming using the knowledge gained from recent ICD trials can decrease inappropriate and unnecessary ICD therapies and decrease mortality.

  9. A new system of implant abutment connection: how to improve a two piece implant system sealing.

    Science.gov (United States)

    Grecchi, F; DI Girolamo, M; Cura, F; Candotto, V; Carinci, F

    2017-01-01

    Implant dentistry has become one of the most successful dentistry techniques for replacing missing teeth. The success rate of implant dentistry is above 80%. However, peri-implantitis is a later complication of implant dentistry that if untreated, can lead to implant loss. One of the hypotized causes of peri-implantis is the bacterial leakage at the level of implant-abutment connection. Bacterial leakage is favored to the presence of a micro gap at the implant-abutment interface, allowing microorganisms to penetrate and colonize the inner part of the implant leading to biofilm accumulation and consequently to peri-implantitis development. To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Implants were immerged in a bacterial culture for twenty-four hours and then bacteria amount was measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 9%. The reported results are better to those of previous studies carried out on different implant systems. Until now, none implant-abutment system has been proven to seal the gap between implant and abutment.

  10. Implantable medical electronics prosthetics, drug delivery, and health monitoring

    CERN Document Server

    Khanna, Vinod Kumar

    2016-01-01

    This book is a comprehensive, interdisciplinary resource for the latest information on implantable medical devices, and is intended for graduate students studying electrical engineering, electronic instrumentation, and biomedical engineering. It is also appropriate for academic researchers, professional engineers, practicing doctors, and paramedical staff. Divided into two sections on Basic Concepts and Principles, and Applications, the first section provides an all-embracing perspective of the electronics background necessary for this work. The second section deals with pacing techniques used for the heart, brain, spinal cord, and the network of nerves that interlink the brain and spinal cord with the major organs, including ear and eye prostheses. The four main offshoots of implantable electronics, which this book discusses, are: The insertion of an implantable neural amplifier for accurate recording of neural signals for neuroengineering studies The use of implantable pulse generators for pacing the activi...

  11. Pacing the US magnetic fusion program

    International Nuclear Information System (INIS)

    1989-01-01

    This study addresses the priority and pace of the nation's magnetic fusion research and development program in the context of long-term national energy policy. In particular, the committee interpreted its task as follows: To review the implications of long-term national energy policy for current research and development in magnetic fusion; to identify factors that should enter the further development of such policy to reduce risks associated with the future electricity supply system; to propose criteria applicable to research and develop in electric generation in reaching long-term energy policy goals; to apply these criteria to magnetic fusion and alternative electric generation technologies in order to develop recommendations on the priority pace of the magnetic fusion program; and to present its results in a final report. The most important goals of the US Department of Energy's current Magnetic Fusion Energy Program Plan are to demonstrate the scientific and engineering feasibility of fusion, Demonstrating engineering feasibility will require the design, construction, and operation of an engineering test reactor, which the plan envisions financing through a combination of domestic and international funding. The committee believes that current domestic program funding levels are inadequate to meet even the near-term objectives of the plan

  12. Silicone implant incompatibility syndrome (SIIS) in a 57-year-old woman with unilateral silicone breast implant

    DEFF Research Database (Denmark)

    Schierbeck, Juliane; Davidsen, Jesper Rømhild; Grindsted Nielsen, Sanne

    2017-01-01

    implants can lead to different interstitial lung manifestations predominantly with granuloma evolvement, leading to the so-called silicone implant incompatibility syndrome (SIIS). This case describes a 57-year-old woman with multiple lung infiltrations and a left-sided breast implant. The implant had been...

  13. Electromagnetic Interference in Patients with Implanted Cardioverter-Defibrillators and Implantable Loop Recorders

    Directory of Open Access Journals (Sweden)

    Marcos de Sousa

    2002-07-01

    Full Text Available Modern life exposes us all to an ever-increasing number of potential sources of electromagnetic interference (EMI and patients with Implantable rhythm devices (IRD like pacemakers, implantable cardioverter defibrillators or implantable loop recorders often ask about the use of microwave ovens, walking through airport metal detectors and the use of cellular phones. Electromagnetic interference occurs when electromagnetic waves emitted by one device impede the normal function of another electronic device. The potential for interaction between implanted pacing systems and cardioverter-defibrillators (electromagnetic interference, EMI has been recognized for years.1,2,3,4. It has been shown that EMI can produce clinically significant effects on patients with implanted pacemakers and ICDs. For these reasons the following text discusses the influence of several EMI generating devices on IRD .

  14. Interatrial septum pacing decreases atrial dyssynchrony on strain rate imaging compared with right atrial appendage pacing.

    Science.gov (United States)

    Yasuoka, Yoshinori; Abe, Haruhiko; Umekawa, Seiko; Katsuki, Keiko; Tanaka, Norio; Araki, Ryo; Imanaka, Takahiro; Matsutera, Ryo; Morisawa, Daisuke; Kitada, Hirokazu; Hattori, Susumu; Noda, Yoshiki; Adachi, Hidenori; Sasaki, Tatsuya; Miyatake, Kunio

    2011-03-01

    Interatrial septum pacing (IAS-P) decreases atrial conduction delay compared with right atrial appendage pacing (RAA-P). We evaluate the atrial contraction with strain rate of tissue Doppler imaging (TDI) during sinus activation or with IAS-P or RAA-P. Fifty-two patients with permanent pacemaker for sinus node disease were enrolled in the study. Twenty-three subjects were with IAS-P and 29 with RAA-P. The time from end-diastole to peak end-diastolic strain rate was measured and corrected with RR interval on electrocardiogram. It was defined as the time from end-diastole to peak end-diastolic strain rate (TSRc), and the balance between maximum and minimum TSRc at three sites (ΔTSRc) was compared during sinus activation and with pacing rhythm in each group. There were no significant differences observed in general characteristics and standard echocardiographic parameters except the duration of pacing P wave between the two groups. The duration was significantly shorter in the IAS-P group compared with the RAA-P group (95 ± 34 vs 138 ± 41; P = 0.001). TSRc was significantly different between sinus activation and pacing rhythm (36.3 ± 35.7 vs 61.6 ± 36.3; P = 0.003) in the RAA-P group, whereas no significant differences were observed in the IAS-P group (25.4 ± 12.1 vs 27.7 ± 14.7; NS). During the follow-up (mean 2.4 ± 0.7 years), the incidence of paroxysmal atrial fibrillation (AF) conversion to permanent AF was not significantly different between the two groups. IAS-P decreased the contraction delay on atrial TDI compared to RAA-P; however, it did not contribute to the reduction of AF incidence in the present study. ©2010, The Authors. Journal compilation ©2010 Wiley Periodicals, Inc.

  15. Electrical storm after CRT implantation treated by AV delay optimization.

    Science.gov (United States)

    Combes, Nicolas; Marijon, Eloi; Boveda, Serge; Albenque, Jean-Paul

    2010-02-01

    We present a case of symptomatic ischemic heart failure with an indication for cardiac resynchronization and implantable cardiac defibrillator therapy in primary prevention. After implantation, the patient developed a severe electrical storm with multiple shocks. Hemodynamic improvement based only on AV delay, guided by echocardiography and ECG, brought about a dramatic improvement in the situation. We discuss the pathophysiology of electrical storm occurring immediately after LV pacing.

  16. Enact legislation supporting residential property assessed clean energy financing (PACE)

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Devashree

    2012-11-15

    Congress should enact legislation that supports residential property assessed clean energy (PACE) programs in the nation’s states and metropolitan areas. Such legislation should require the Federal Housing Finance Agency (FHFA) to allow Fannie Mae and Freddie Mac to purchase residential mortgages with PACE assessments while at the same time providing responsible underwriting standards and a set of benchmarks for residential PACE assessments in order to minimize financial risks to mortgage holders. Congressional support of residential PACE financing will improve energy efficiency, encourage job creation, and foster economic growth in the nation’s state and metropolitan areas.

  17. Noninvasive external cardiac pacing for thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Feldman, M.D.; Warren, S.E.; Gervino, E.V.

    1988-01-01

    Improvements in noninvasive external cardiac pacing have led to a technique with reliable electrical capture and tolerable patient discomfort. To assess the use of this modality of pacing in combination with thallium scintigraphy as a noninvasive pacing stress test, we applied simultaneous noninvasive cardiac pacing, hemodynamic monitoring, and thallium-201 scintigraphy in 14 patients undergoing cardiac catheterization for chest pain syndromes. Two patients had normal coronary arteries, while the remaining 12 had significant coronary artery disease. Thallium scintigraphic responses to pacing were compared to routine exercise thallium stress testing in nine of these 14 patients. All patients were noninvasively paced to more than 85% of the age-predicted maximum heart rate. Twelve patients demonstrated reversible thallium defects, which corresponded in 11 cases to significant lesions seen on coronary angiography. Of nine patients who underwent both pacing and exercise thallium stress tests, comparable maximal rate-pressure products were achieved. Moreover, thallium imaging at peak pacing and during delayed views did not differ significantly from exercise thallium scintigraphy. A limiting factor associated with the technique was local patient discomfort, which occurred to some degree in all patients. We conclude that noninvasive external cardiac pacing together with thallium scintigraphy is capable of detecting significant coronary artery disease and may be comparable to routine exercise thallium stress testing. This new modality of stress testing could be useful in patients unable to undergo the exercise required for standard exercise tolerance testing, particularly if improvements in the technology can be found to reduce further the local discomfort

  18. Endometrial scratching in women with implantation failure after a first IVF/ICSI cycle; does it lead to a higher live birth rate? The SCRaTCH study: A randomized controlled trial (NTR 5342)

    NARCIS (Netherlands)

    van Hoogenhuijze, N.E.; H.L. Torrance (Helen); F. Mol (Femke); J.S.E. Laven (Joop); Scheenjes, E.; T. Traas (Theo); Janssen, C.; B.J. Cohlen (Ben); G. Teklenburg (Gijs); J.P. de Bruin (J.); van Oppenraaij, R.; Maas, J.W.M.; Moll, E.; K. Fleischer; M.H.A. van Hooff (Marcel); C.H. de Koning; A.E.P. Cantineau (Astrid); C.B. Lambalk (Cornelius); M.F.G. Verberg; Nijs, M.; Manger, A.P.; M.M.E. van Rumste (Minouche); van der Voet, L.F.; Preys-Bosman, A.; Visser, J.; Brinkhuis, E.; den Hartog, J.E.; A. Sluijmer (Alexander); Jansen, F.W.; Hermes, W.; Bandell, M.L.; Pelinck, M.J.; J. van Disseldorp (Jeroen); M. van Wely (Madelon); J.M.J. Smeenk; Pieterse, Q.D.; J.C. Boxmeer (Jolanda); Groenewoud, E.R.; M.J.C. Eijkemans (René); J.C. Kasius (J. C.); F.J.M. Broekmans (Frank)

    2017-01-01

    textabstractBackground: Success rates of assisted reproductive techniques (ART) are approximately 30%, with the most important limiting factor being embryo implantation. Mechanical endometrial injury, also called 'scratching', has been proposed to positively affect the chance of implantation after

  19. Endometrial scratching in women with implantation failure after a first IVF/ICSI cycle; does it lead to a higher live birth rate? The SCRaTCH study: a randomized controlled trial (NTR 5342)

    NARCIS (Netherlands)

    Hoogenhuijze, N.E. van; Torrance, H.L.; Mol, F.; Laven, J.S.; Scheenjes, E.; Traas, M.A.F.; Janssen, C.; Cohlen, B.; Teklenburg, G.; Bruin, J.P. de; Oppenraaij, R. van; Maas, J.W.; Moll, E.; Fleischer, K.; Hooff, M.H. van; Koning, C.; Cantineau, A.; Lambalk, C.B.; Verberg, M.; Nijs, M.; Manger, A.P.; Rumste, M. van; Voet, L.F. van der; Preys-Bosman, A.; Visser, J.; Brinkhuis, E.; Hartog, J.E. Den; Sluijmer, A.; Jansen, F.W.; Hermes, W.; Bandell, M.L.; Pelinck, M.J.; Disseldorp, J. van; Wely, M. van; Smeenk, J.; Pieterse, Q.D.; Boxmeer, J.C.; Groenewoud, E.R.; Eijkemans, M.J.; Kasius, J.C.; Broekmans, F.J.

    2017-01-01

    BACKGROUND: Success rates of assisted reproductive techniques (ART) are approximately 30%, with the most important limiting factor being embryo implantation. Mechanical endometrial injury, also called 'scratching', has been proposed to positively affect the chance of implantation after embryo

  20. Endometrial scratching in women with implantation failure after a first IVF/ICSI cycle; does it lead to a higher live birth rate? The SCRaTCH study: a randomized controlled trial (NTR 5342)

    NARCIS (Netherlands)

    van Hoogenhuijze, N. E.; Torrance, H. L.; Mol, F.; Laven, J. S. E.; Scheenjes, E.; Traas, M. A. F.; Janssen, C.; Cohlen, B.; Teklenburg, G.; de Bruin, J. P.; van Oppenraaij, R.; Maas, J. W. M.; Moll, E.; Fleischer, K.; van Hooff, M. H.; de Koning, C.; Cantineau, A.; Lambalk, C. B.; Verberg, M.; Nijs, M.; Manger, A. P.; van Rumste, M.; van der Voet, L. F.; Preys-Bosman, A.; Visser, J.; Brinkhuis, E.; den Hartog, J. E.; Sluijmer, A.; Jansen, F. W.; Hermes, W.; Bandell, M. L.; Pelinck, M. J.; van Disseldorp, J.; van Wely, M.; Smeenk, J.; Pieterse, Q. D.; Boxmeer, J. C.; Groenewoud, E. R.; Eijkemans, M. J. C.; Kasius, J. C.; Broekmans, F. J. M.

    2017-01-01

    Success rates of assisted reproductive techniques (ART) are approximately 30%, with the most important limiting factor being embryo implantation. Mechanical endometrial injury, also called 'scratching', has been proposed to positively affect the chance of implantation after embryo transfer, but the

  1. Endometrial scratching in women with implantation failure after a first IVF/ICSI cycle; does it lead to a higher live birth rate? The SCRaTCH study : A randomized controlled trial (NTR 5342)

    NARCIS (Netherlands)

    van Hoogenhuijze, N. E.; Torrance, H. L.; Mol, F.; Laven, Joop S E; Scheenjes, E.; Traas, M.A.F.; Janssen, Bert J C; Cohlen, B.; Teklenburg, G.; Bruin, Jacob P; van Oppenraaij, R.; Maas, J. W M; Moll, Etelka; Fleischer, K.; van Hooff, Marcel H; de Koning, C.; Cantineau, A.; Lambalk, Cornelis B.; Verberg, M.F.G.; Nijs, M. M.; Manger, A. P.; Van Rumste, M. M.; Van der Voet, L F; Preys-Bosman, A.; Visser, J.; Brinkhuis, E.A.; den Hartog, J. E.; Sluijmer, A.; Jansen, F. W.; Hermes, W.; Bandell, M. L.; Pelinck, M. J.; van Disseldorp, J.; Wely, M.; Smeenk, J.; Pieterse, Q.D.; Boxmeer, J.C.; Groenewoud, Eva R.; Eijkemans, M. J.C.; Kasius, J. C.; Broekmans, F. J.M.

    2017-01-01

    Background: Success rates of assisted reproductive techniques (ART) are approximately 30%, with the most important limiting factor being embryo implantation. Mechanical endometrial injury, also called 'scratching', has been proposed to positively affect the chance of implantation after embryo

  2. The Subcutaneous Implantable Cardioverter-Defibrillator: A Practical Review and Real-World Use and Application

    Directory of Open Access Journals (Sweden)

    Mark E. Panna Jr, MD, FACC, FHRS

    2016-02-01

    Full Text Available The subcutaneous implantable cardioverter-defibrillator (ICD is a novel technology using a subcutaneous (extrathoracic system for treatment of potential lethal ventricular arrhythmias. It avoids many of the risks of transvenous ICD implantation. It may be considered in patients having an ICD indication who do not have a pacing and/or cardiac resynchronization therapy indication, and who are unlikely to benefit from antitachycardia pacing therapy. We review patient selection, system components, the implantation technique, and screening considerations for subcutaneous ICD implantation. Its uses in specific patient populations, including children, patients with congenital heart disease, hypertrophic cardiomyopathy, or end-stage renal disease, and patients with preexisting pacemakers, are highlighted. Areas of future investigation are reviewed, including potential use with leadless pacing and magnetic resonance imaging.

  3. Hibernia field construction pace picks up speed

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This paper reports that the pace of construction is increasing for the $5.2 billion (Canadian) Hibernia oil field development project off Newfoundland with a new partner close to signing on. Texaco, Inc. is reported ready to pick up a 25% interest in the project within a month. Construction activity for offshore systems was cut 50% last February when Gulf Canada Resources Inc. The it planned to withdraw from its 25% interest in Hibernia. Since then, remaining interest owners Mobil Oil Canada Ltd., Chevron Canada Resources Ltd., and Petro-Canada have been seeking new partners. The effort has focused on Texaco with Canadian Energy Minister Jake Epp playing a role in talks. Hibernia's construction work force has risen to 850 from a low of 600. A spokesman for Hibernia Management and Development Co., project manager, the a steady increase in the work force is planned

  4. IAEA instrumentation programme keeping pace with technology

    International Nuclear Information System (INIS)

    Fortakov, V.; Rundquist, D.E.

    1995-01-01

    Nuclear components, nuclear practices and nuclear facilities have all improved with the maturing of the industry. These improvements have been driven by forces, which are beyond the normal evolutionary pressures, such as increased safety, as low as possible radiation exposure for the workers as well as for the public and the increasing competiveness of alternative forms of energy generation. International nuclear safeguards has had to keep pace with these technological and administrative changes. Moreover, the political climate has changed since the initial implementation of safeguards under the Non-Proliferation Treaty. Implementation of safeguards agreements has accommodated to these changes as well as to the technical innovations. One important component of safeguards implementation, namely the instruments deployed by inspectors, has matured with the help of Member States. Continued efforts in the development and deployment of appropriate instruments are needed to maintain an acceptable level of efficiency and credibility. (orig.)

  5. Is right ventricular mid-septal pacing superior to apical pacing in patients with high degree atrio-ventricular block and moderately depressed left ventricular function?

    Science.gov (United States)

    Chen, Kang; Mao, Ye; Liu, Shao-hua; Wu, Qiong; Luo, Qing-zhi; Pan, Wen-qi; Jin, Qi; Zhang, Ning; Ling, Tian-you; Chen, Ying; Gu, Gang; Shen, Wei-feng; Wu, Li-qun

    2014-06-01

    We are aimed to investigate whether right ventricular mid-septal pacing (RVMSP) is superior to conventional right ventricular apical pacing (RVAP) in improving clinical functional capacity and left ventricular ejection fraction (LVEF) for patients with high-degree atrio-ventricular block and moderately depressed left ventricle (LV) function. Ninety-two patients with high-degree atrio-ventricular block and moderately reduced LVEF (ranging from 35% to 50%) were randomly allocated to RVMSP (n=45) and RVAP (n=47). New York Heart Association (NYHA) functional class, echocardiographic LVEF, and distance during a 6-min walk test (6MWT) were determined at 18 months after pacemaker implantation. Serum levels of N-terminal pro-brain natriuretic peptide (NT-proBNP) were measured using an enzyme-linked immunosorbent assay (ELISA) kit. Compared with baseline, NYHA functional class remained unchanged at 18 months, distance during 6MWT (485 m vs. 517 m) and LVEF (36.7% vs. 41.8%) were increased, but BNP levels were reduced (2352 pg/ml vs. 710 pg/ml) in the RVMSP group compared with those in the RVAP group, especially in patients with LVEF 35%-40% (for all comparisons, Pfunction capacity and LV function measurements were not significantly changed in patients with RVAP, despite the pacing measurements being similar in both groups, such as R-wave amplitude and capture threshold. RVMSP provides a better clinical utility, compared with RVAP, in patients with high-degree atrioventricular block and moderately depressed LV function whose LVEF levels ranged from 35% to 40%.

  6. Proton Beam Therapy Interference With Implanted Cardiac Pacemakers

    International Nuclear Information System (INIS)

    Oshiro, Yoshiko; Sugahara, Shinji; Noma, Mio; Sato, Masato; Sakakibara, Yuzuru; Sakae, Takeji; Hayashi, Yasutaka; Nakayama, Hidetsugu; Tsuboi, Koji; Fukumitsu, Nobuyoshi; Kanemoto, Ayae; Hashimoto, Takayuki; Tokuuye, Koichi

    2008-01-01

    Purpose: To investigate the effect of proton beam therapy (PBT) on implanted cardiac pacemaker function. Methods and Materials: After a phantom study confirmed the safety of PBT in patients with cardiac pacemakers, we treated 8 patients with implanted pacemakers using PBT to a total tumor dose of 33-77 gray equivalents (GyE) in dose fractions of 2.2-6.6 GyE. The combined total number of PBT sessions was 127. Although all pulse generators remained outside the treatment field, 4 patients had pacing leads in the radiation field. All patients were monitored by means of electrocardiogram during treatment, and pacemakers were routinely examined before and after PBT. Results: The phantom study showed no effect of neutron scatter on pacemaker generators. In the study, changes in heart rate occurred three times (2.4%) in 2 patients. However, these patients remained completely asymptomatic throughout the PBT course. Conclusions: PBT can result in pacemaker malfunctions that manifest as changes in pulse rate and pulse patterns. Therefore, patients with cardiac pacemakers should be monitored by means of electrocardiogram during PBT

  7. Applicability of existing magnesium alloys as biomedical implant materials

    NARCIS (Netherlands)

    Erinc, M.; Sillekens, W.H.; Mannens, R.G.T.M.; Werkhoven, R.J.

    2009-01-01

    Being biocompatible and biodegradable, magnesium alloys are considered as the new generation biomedical implant materials, such as for stents, bone fixtures, plates and screws. A major drawback is the poor chemical stability of metallic magnesium; it corrodes at a pace that is too high for most

  8. PACE3 - front-end chip for the CMS Preshower

    CERN Multimedia

    Aspel, Paul

    2003-01-01

    This is PACE3 which is the front-end chip for the CMS Preshower. In fact PACE3 is the combination of two ASICs called Delta3 and PACEAM3. Delta3 is on the left and PACEAM3 is on the right. The two ASICs are bonded together and then packaged within a single 196 pin fpBGA package.

  9. Social Interaction in Self-Paced Distance Education

    Science.gov (United States)

    Anderson, Terry; Upton, Lorne; Dron, Jon; Malone, Judi; Poelhuber, Bruno

    2015-01-01

    In this paper we present a case study of a self-paced university course that was originally designed to support independent, self-paced study at distance. We developed a social media intervention, in design-based research terms, that allows these independent students to contribute archived content to enhance the course, to engage in discussions…

  10. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  11. An Undergraduate Intern Program at PACES

    Science.gov (United States)

    Starks, Scott A.

    1997-01-01

    The University of Texas at El Paso (UTEP) established the Pan American Center for Earth and Environmental Studies (PACES) in 1995 to conduct basic and applied research that contributes to NASA's Mission to Planet Earth. Specifically, PACES provides a repository of remote sensing and other information that supports investigations into an improved understanding of geological, ecological and environmental processes occurring in the southwestern United States and Northern Mexico. Approximately 85% of UTEP's students come from El Paso County, a fast growing urban region representative of many large cities in the Southwest that have, or will soon have, a majority of their population composed of groups currently underrepresented in the scientific and technical workforce. UTEP's student population has an ethnic distribution (63% Hispanic, 32% Anglo, 3% African American, 1.5 % Asian American, and less than 1% Native American) that closely matches the demographics of the region it serves. Thus, UTEP has a mission to serve a multicultural population where minority students comprise the majority. Most Hispanic students at UTEP are primarily of Mexican origin. A large number are first or second-generation U.S. citizens. Characteristics that unite Hispanic students, in particular those of Mexican-origin, are a strong sense of family loyalty and a belief that all family members are responsible for contributing to the economic stability and well-being of the family. Most of their families are larger in number than the national average, and a variety of generations live together or share considerable resources. Thus, many young people feel an obligation and a desire to go to work at a young age and to continue working while in college, thereby assisting their parents and other family members. Older siblings understand that they have responsibilities to do household chores, to aid their younger siblings economically, and to assist elderly family members. This "work ethic" within the

  12. Acute evaluation of transthoracic impedance vectors using ICD leads.

    Science.gov (United States)

    Gottfridsson, Christer; Daum, Douglas; Kennergren, Charles; Ramuzat, Agnès; Willems, Roger; Edvardsson, Nils

    2009-06-01

    Minute ventilation (MV) has been proven to be very useful in rate responsive pacing. The aim of this study was to evaluate the feasibility of using implantable cardioverter-defibrillator (ICD) leads as part of the MV detection system. At implant in 10 patients, the transthoracic impedance was measured from tripolar ICD, tetrapolar ICD, and atrial lead vectors during normal, deep, and shallow voluntary respiration. MV and respiration rate (RespR) were simultaneously measured through a facemask with a pneumotachometer (Korr), and the correlations with impedance-based measurements were calculated. Air sensitivity was the change in impedance per change in respiratory tidal volume, ohms (Omega)/liter (L), and the signal-to-noise ratio (SNR) was the ratio of the respiratory and cardiac contraction components. The air sensitivity and SNR in tripolar ICD vector were 2.70 +/- 2.73 ohm/L and 2.19 +/- 1.31, respectively, and were not different from tetrapolar. The difference in RespR between tripolar ICD and Korr was 0.2 +/- 1.91 breaths/minute. The regressed correlation coefficient between impedance MV and Korr MV was 0.86 +/- 0.07 in tripolar ICD. The air sensitivity and SNR in tripolar and tetrapolar ICD lead vectors did not differ significantly and were in the range of the values in pacemaker leads currently used as MV sensors. The good correlations between impedance-based and Korr-based RespR and MV measurements imply that ICD leads may be used in MV sensor systems.

  13. Impact of pacing on systemic ventricular function in L-transposition of the great arteries.

    Science.gov (United States)

    Hofferberth, Sophie C; Alexander, Mark E; Mah, Douglas Y; Bautista-Hernandez, Victor; del Nido, Pedro J; Fynn-Thompson, Francis

    2016-01-01

    To assess the impact of univentricular versus biventricular pacing (BiVP) on systemic ventricular function in patients with congenitally corrected transposition of the great arteries (ccTGA). We performed a retrospective review of all patients with a diagnosis of ccTGA who underwent pacemaker insertion. From 1993 to 2014, 53 patients were identified from the cardiology database and surgical records. Overall mortality was 7.5% (n = 4). One patient required transplantation and 3 late deaths occurred secondary to end-stage heart failure. Median follow-up was 3.7 years (range, 4 days to 22.5 years). Twenty-five (47%) underwent univentricular pacing only, of these, 8 (32%) developed significant systemic ventricular dysfunction. Twenty-eight (53%) received BiVP, 17 (26%) were upgraded from a dual-chamber system, 11 (21%) received primary BiVP. Fourteen (82%) of the 17 undergoing secondary BiVP demonstrated systemic ventricular dysfunction at the time of pacer upgrade, with 7 (50%) demonstrating improved systemic ventricular function after pacemaker upgrade. Overall, 42 (79%) patients underwent univentricular pacing, with 22 (52%) developing significant systemic ventricular dysfunction. In contrast, the 11 (21%) who received primary BiVP had preserved systemic ventricular function at latest follow-up. Late-onset systemic ventricular dysfunction is a major complication associated with the use of univentricular pacing in patients with ccTGA. All patients with ccTGA who develop heart block should undergo primary biventricular pacing, as this prevents late systemic ventricular dysfunction. Preemptive placement of BiVP leads at the time of anatomical repair or other permanent palliative procedure will facilitate subsequent BiVP should heart block develop. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  14. Antifibrillatory effects of renal denervation on ventricular fibrillation in a canine model of pacing-induced heart failure.

    Science.gov (United States)

    Luo, Qingzhi; Jin, Qi; Zhang, Ning; Huang, Shangwei; Han, Yanxin; Lin, Changjian; Ling, Tianyou; Chen, Kang; Pan, Wenqi; Wu, Liqun

    2018-01-01

    What is the central question of this study? In the present study, we investigated the effects of renal denervation on the vulnerability to ventricular fibrillation and the ventricular electrical properties in a rapid pacing-induced heart failure canine model. What is the main finding and its importance? Renal denervation significantly attenuated the process of heart failure and improved left ventricular systolic dysfunction, stabilized ventricular electrophysiological properties and decreased the vulnerability of the heart to ventricular fibrillation during heart failure. Thus, renal denervation can attenuate ventricular electrical remodelling and exert a potential antifibrillatory action in a pacing-induced heart failure canine model. In this study, we investigated the effects of renal denervation (RDN) on the vulnerability to ventricular fibrillation (VF) and the ventricular electrical properties in a canine model of pacing-induced heart failure (HF). Eighteen beagles were divided into the following three groups: control (n = 6), HF (n = 6) and HF+RDN (n = 6). Heart failure was induced by rapid right ventricular pacing. Renal denervation was performed simultaneously with the pacemaker implantation in the HF+RDN group. A 64-unipolar basket catheter was used to perform global endocardial mapping of the left ventricle. The restitution properties and dispersion of refractoriness were estimated from the activation recovery intervals (ARIs) by a pacing protocol. The VF threshold (VFT) was defined as the maximal pacing cycle length required to induce VF using a specific pacing protocol. The defibrillation threshold (DFT) was measured by an up-down algorithm. Renal denervation partly restored left ventricular systolic function and attenuated the process of HF. Compared with the control group, the VFT in the HF group was decreased by 27% (106 ± 8.0 versus 135 ± 10 ms, P Renal denervation significantly flattened the ventricular ARI restitution curve by 15% (1

  15. Pushing the pace of tree species migration.

    Directory of Open Access Journals (Sweden)

    Eli D Lazarus

    Full Text Available Plants and animals have responded to past climate changes by migrating with habitable environments, sometimes shifting the boundaries of their geographic ranges by tens of kilometers per year or more. Species migrating in response to present climate conditions, however, must contend with landscapes fragmented by anthropogenic disturbance. We consider this problem in the context of wind-dispersed tree species. Mechanisms of long-distance seed dispersal make these species capable of rapid migration rates. Models of species-front migration suggest that even tree species with the capacity for long-distance dispersal will be unable to keep pace with future spatial changes in temperature gradients, exclusive of habitat fragmentation effects. Here we present a numerical model that captures the salient dynamics of migration by long-distance dispersal for a generic tree species. We then use the model to explore the possible effects of assisted colonization within a fragmented landscape under a simulated tree-planting scheme. Our results suggest that an assisted-colonization program could accelerate species-front migration rates enough to match the speed of climate change, but such a program would involve an environmental-sustainability intervention at a massive scale.

  16. Osteoporotic rat models for evaluation of osseointegration of bone implants

    NARCIS (Netherlands)

    Alghamdi, H.S.A.; Beucken, J.J.J.P van den; Jansen, J.A.

    2014-01-01

    Osseointegration of dental and orthopedic bone implants is the important process that leads to mechanical fixation of implants and warrants implant functionality. In view of increasing numbers of osteoporotic patients, bone implant surface optimization strategies with instructive and drug-loading

  17. The pace of aging: Intrinsic time scales in demography

    Directory of Open Access Journals (Sweden)

    Tomasz Wrycza

    2014-05-01

    Full Text Available Background: The pace of aging is a concept that captures the time-related aspect of aging. It formalizesthe idea of a characteristic life span or intrinsic population time scale. In the rapidly developing field of comparative biodemography, measures that account for inter-speciesdifferences in life span are needed to compare how species age. Objective: We aim to provide a mathematical foundation for the concept of pace. We derive desiredmathematical properties of pace measures and suggest candidates which satisfy these properties. Subsequently, we introduce the concept of pace-standardization, which reveals differences in demographic quantities that are not due to pace. Examples and consequences are discussed. Conclusions: Mean life span (i.e., life expectancy from birth or from maturity is intuitively appealing,theoretically justified, and the most appropriate measure of pace. Pace-standardizationprovides a serviceable method for comparative aging studies to explore differences indemographic patterns of aging across species, and it may considerably alter conclusionsabout the strength of aging.

  18. Transvenous versus open chest lead placement for resynchronization therapy in patients with heart failure: comparison of ventricular electromechanical synchronicity.

    Science.gov (United States)

    Zhang, Hai-Bo; Meng, Xu; Han, Jie; Li, Yan; Zhang, Ye; Jiang, Teng-Yong; Zhao, Ying-Xin; Zhou, Yu-Jie

    2017-04-01

    Transvenous lead placement is the standard approach for left ventricular (LV) pacing in cardiac resynchronization therapy (CRT), while the open chest access epicardial lead placement is currently the most frequently used second choice. Our study aimed to compare the ventricular electromechanical synchronicity in patients with heart failure after CRT with these two different LV pacing techniques. We enrolled 33 consecutive patients with refractory heart failure secondly to dilated cardiomyopathy who were eligible for CRT in this study. Nineteen patients received transvenous (TV group) while 14 received open chest (OP group) LV lead pacing. Intra- and inter-ventricular electromechanical synchronicity was assessed by tissue Doppler imaging (TDI) before and one year after CRT procedure. Before CRT procedure, the mean QRS-duration, maximum time difference to systolic peak velocity among 12 left ventricle segments (LV Ts-12), standard deviation of time difference to systolic peak velocity of 12 left ventricle segments (LV Ts-SD), and inter-ventricular mechanical delay (IVMD) in OP and TV group were 166 ± 17 ms and 170 ± 21 ms, 391 ± 42 ms and 397 ± 36 ms, 144 ± 30 ms and 148 ± 22 ms, 58 ± 25 ms and 60 ± 36 ms, respectively (all P > 0.05). At one year after the CRT, the mean QRS-duration, LV Ts-12, LV Ts-SD, and IVMD in TV and OP group were 128 ± 14 ms and 141 ± 22 ms ( P = 0.031), 136 ± 37 ms and 294 ± 119 ms ( P = 0.023), 50 ± 22 ms and 96 ± 34 ms ( P = 0.015), 27 ± 11 ms and 27 ± 26 ms ( P = 0.86), respectively. The LV lead implantation procedure time was 53.4 ± 16.3 min for OP group and 136 ± 35.1 min for TV group ( P = 0.016). The mean LV pacing threshold increased significantly from 1.7 ± 0.6 V/0.5 ms to 2.3 ± 1.6 V/0.5 ms ( P open chest access of LV pacing for CRT leads to better improvement of the intraventricular synchronization.

  19. Pacing: a concept analysis of the chronic pain intervention.

    Science.gov (United States)

    Jamieson-Lega, Kathryn; Berry, Robyn; Brown, Cary A

    2013-01-01

    The intervention of pacing is regularly recommended for chronic pain patients. However, pacing is poorly defined and appears to be interpreted in varying, potentially contradictory manners within the field of chronic pain. This conceptual lack of clarity has implications for effective service delivery and for researchers' ability to conduct rigorous study. An examination of the background literature demonstrates that while pacing is often one part of a multidisciplinary pain management program, outcome research is hindered by a lack of a clear and shared definition of this currently ill-defined construct. To conduct a formal concept analysis of the term 'pacing'. A standardized concept analysis process (including literature scoping to identify all uses of the concept, analysis to determine defining attributes of the concept and identification of model, borderline and contrary cases) was used to determine what the concept of pacing does and does not represent within the current evidence base. A conceptual model including the core attributes of action, time, balance, learning and self-management emerged. From these attributes, an evidence-based definition for pacing was composed and distributed to stakeholders for review. After consideration of stakeholder feedback, the emergent definition of pacing was finalized as follows: "Pacing is an active self-management strategy whereby individuals learn to balance time spent on activity and rest for the purpose of achieving increased function and participation in meaningful activities". The findings of the present concept analysis will help to standardize the use and definition of the term pacing across disciplines for the purposes of both pain management and research.

  20. Environmental proxies of antigen exposure explain variation in immune investment better than indices of pace of life

    NARCIS (Netherlands)

    Horrocks, Nicholas P. C.; Hegemann, Arne; Ostrowski, Stephane; Ndithia, Henry; Shobrak, Mohammed; Williams, Joseph B.; Matson, Kevin D.; Tieleman, B. I.

    Investment in immune defences is predicted to covary with a variety of ecologically and evolutionarily relevant axes, with pace of life and environmental antigen exposure being two examples. These axes may themselves covary directly or inversely, and such relationships can lead to conflicting

  1. Environmental proxies of antigen exposure explain variation in immune investment better than indices of pace of life

    NARCIS (Netherlands)

    Horrocks, N.P.C.; Hegemann, A.; Ostrowski, S.; Ndithia, H.; Shobrak, M.; Williams, J.B.; Matson, K.D.; Tieleman, B.I.

    2015-01-01

    Investment in immune defences is predicted to covary with a variety of ecologically and evolutionarily relevant axes, with pace of life and environmental antigen exposure being two examples. These axes may themselves covary directly or inversely, and such relationships can lead to conflicting

  2. Similarities and Differences in Pacing Patterns in a 161-km and 101-km Ultra-Distance Road Race.

    Science.gov (United States)

    Tan, Philip L S; Tan, Frankie H Y; Bosch, Andrew N

    2016-08-01

    Tan, PLS, Tan, FHY, and Bosch, AN. Similarities and differences in pacing patterns in a 161-km and 101-km ultra-distance road race. J Strength Cond Res 30(8): 2145-2155, 2016-The purpose of this study was to establish and compare the pacing patterns of fast and slow finishers in a tropical ultra-marathon. Data were collected from the Craze Ultra-marathon held on the 22nd and 21st of September in 2012 and 2013, respectively. Finishers of the 161-km (N = 47) and 101-km (N = 120) categories of the race were divided into thirds (groups A-C) by merit of finishing time. Altogether, 17 and 11 split times were recorded for the 161-km and 101-km finishers, respectively, and used to calculate the mean running speed for each distance segment. Running speed for the first segment was normalized to 100, with all subsequent splits adjusted accordingly. Running speed during the last 5 km was calculated against the mean race pace to establish the existence of an end spurt. A reverse J-shaped pacing profile was demonstrated in all groups for both distance categories and only 38% of the finishers executed an end spurt. In the 101-km category, in comparison with groups B and C, group A maintained a significantly more even pace (p = 0.013 and 0.001, respectively) and completed the race at a significantly higher percent of initial starting speed (p = 0.001 and 0.001, respectively). Descriptive data also revealed that the top 5 finishers displayed a "herd-behavior" by staying close to the lead runner in the initial portion of the race. These findings demonstrate that to achieve a more even pace, recreational ultra-runners should adopt a patient sustainable starting speed, with less competitive runners setting realistic performance goals whereas competitive runners with a specific time goal to consider running in packs of similar pace.

  3. FLOATING ATRIAL SENSING OF THE VDD PACING SYSTEM AND ITS STABILITY

    Directory of Open Access Journals (Sweden)

    Tomislav Kostić

    2014-03-01

    Full Text Available mulate two heart chambers (usually the right atrium and right ventricle were de-signed. Those pacemakers were able to detect signals from the same heart chamber, and each of its functions (detection of intrinsing and application of artificial pacemaker signal was performed as previously programmed. Essential hemodynamic improvement of this type of stimulation was the achievement of AV synchronization allowing that optimized function of the atria and ventricles mimics their natural functioning - timely contraction of the atria in relation to the AV valves and the ventricular outflow tracts. This study included 130 patients who had VDD pacemaker implanted at the Department of Cardiology, Clinical Center Niš, during 2009-2013. At the time of implantation, atrial sensing was 2.1±1.2 mV. Patients had follow up visits at one month, six months and one year after pacemaker implantation. After one year, the floating sensing in the atrium was 1.6±0.7 mV which was lower but not clinically significant. Bearing in mind the aforementioned, VVD pacing systems may be considered as the first line therapy in patients with AV block and normal SA node function, particularly in elderly patients and in patients with unsuitable anatomical structures of musculoskeletal and venous systems of the upper thoracic part, in cases of which it is sometimes difficult to place two DDDR electrode systems.

  4. Transcatheter leadless pacemaker implantation in a patient with a transvenous dual-chamber pacemaker already in place.

    Science.gov (United States)

    Karjalainen, Pasi P; Nammas, Wail; Paana, Tuomas

    2016-01-01

    An 83-year-old lady had a DDDR pacemaker inserted in 1997 for symptomatic atrioventricular block. She underwent battery replacement in 2008. In 2010, she developed atrial fibrillation; the pacemaker was switched to VVIR mode. During the last 2years, ventricular lead threshold increased progressively. In December 2015, she presented for elective battery replacement. After successful battery replacement, the ventricular lead threshold remained high; therefore, we implanted a leadless transcatheter pacemaker, via femoral vein access, using a dedicated catheter delivery system. Electrical measurements at this stage revealed a pacing threshold of 0.28V at 0.24msec, and an impedance of 650Ω. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Recommendations for pacemaker implantation for the treatment of atrial tachyarrhythmias and resynchronisation therapy for heart failure

    Science.gov (United States)

    van Hemel, N.M.; Dijkman, B.; de Voogt, W.G.; Beukema, W.P.; Bosker, H.A.; de Cock, C.C.; Jordaens, L.J.L.M.; van Gelder, I.C.; van Gelder, L.M.; van Mechelen, R.; Ruiter, J.H.; Sedney, M.I.; Slegers, L.C.

    2004-01-01

    Today, new pacing algorithms and stimulation methods for the prevention and interruption of atrial tachyarrhythmias can be applied on patients who need bradycardia pacing for conventional reasons. In addition, biventricular pacing as additive treatment for patients with severe congestive heart failure due to ventricular systolic dysfunction and prolonged intraventricular conduction has shown to improve symptoms and reduce hospital admissions. These new pacing technologies and the optimising of the pacing programmes are complex, expensive and time-consuming. Based on many clinical studies the indications for these devices are beginning to emerge. To support the cardiologist's decision-making and to prevent waste of effort and resources, the 'ad hoc committee' has provided preliminary recommendations for implantable devices to treat atrial tachyarrhythmias and to extend the treatment of congestive heart failure respectively. PMID:25696255

  6. Carmustine Implant

    Science.gov (United States)

    ... works by slowing or stopping the growth of cancer cells in your body. ... are pregnant, plan to become pregnant, or are breast-feeding. If you become pregnant while receiving carmustine implant, call your doctor. Carmustine may harm the fetus.

  7. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  8. Classifying running-related injuries based upon etiology, with emphasis on volume and pace

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Oestergaard; Nohr, Ellen Aagaard; Rasmussen, Sten

    2013-01-01

    BACKGROUND AND PURPOSE: Many researchers acknowledge the importance of "training errors" as the main cause of running-related injuries. The purpose of this clinical commentary is to present a theoretical framework for the assumption that some running-related injuries among rear-foot strikers...... of patellofemoral pain syndrome, iliotibial band syndrome, and patellar tendinopathy, while change in running pace may be associated with the development of achilles tendinopathy, gastrocnemius injuries, and plantar fasciitis. DISCUSSIONRELATION TO CLINICAL PRACTICE: If this assertion is correct, bias may...... develop due to rapidly changing running volume, while others develop due to rapidly changing running pace. DESCRIPTION OF TOPIC WITH RELATED EVIDENCE: Evidence from clinical and experimental studies is presented to support the assertion that rapid change in running volume may lead to the development...

  9. Mechanical Alterations during 800-m Self-Paced Track Running.

    Science.gov (United States)

    Girard, Olivier; Millet, Gregoire P; Micallef, Jean-Paul

    2017-04-01

    We assessed the time course of running mechanical alterations during an 800-m. On a 200-m indoor track, 18 physical education students performed an 800-m self-paced run. Once per lap, ground reaction forces were measured by a 5-m-long force platform system, and used to determine running kinetics/kinematics and spring-mass characteristics. Compared with 100 m (19.4±1.8 km.h -1 ) running velocity progressively decreased at 300, 500 m but levelled-off at 700 m marks (-5.7±4.6, -10.4±8.3, and -9.1±13.5%, respectively; Ppush-off forces (-5.1±7.2%, P0.05) and leg compression (+2.8±3.9%; P>0.05) remained unchanged, whereas centre of mass vertical displacement (+24.0±7.0%; P0.05). During an 800 m by physical education students, highest running velocity was achieved early during the run, with a progressive decrease in the second half of the trial. While vertical ground force characteristics remained unchanged, non-specialist runners produced lower peak braking and push-off forces, in turn leading to shorter stride length. Spring-mass model characteristics changed toward lower vertical stiffness values, whereas leg stiffness did not change. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Neutrophil Responses to Sterile Implant Materials.

    Directory of Open Access Journals (Sweden)

    Siddharth Jhunjhunwala

    Full Text Available In vivo implantation of sterile materials and devices results in a foreign body immune response leading to fibrosis of implanted material. Neutrophils, one of the first immune cells to be recruited to implantation sites, have been suggested to contribute to the establishment of the inflammatory microenvironment that initiates the fibrotic response. However, the precise numbers and roles of neutrophils in response to implanted devices remains unclear. Using a mouse model of peritoneal microcapsule implantation, we show 30-500 fold increased neutrophil presence in the peritoneal exudates in response to implants. We demonstrate that these neutrophils secrete increased amounts of a variety of inflammatory cytokines and chemokines. Further, we observe that they participate in the foreign body response through the formation of neutrophil extracellular traps (NETs on implant surfaces. Our results provide new insight into neutrophil function during a foreign body response to peritoneal implants which has implications for the development of biologically compatible medical devices.

  11. Fast Paced, Low Cost Projects at MSFC

    Science.gov (United States)

    Watson-Morgan, Lisa; Clinton, Raymond

    2012-01-01

    What does an orbiting microsatellite, a robotic lander and a ruggedized camera and telescope have in common? They are all fast paced, low cost projects managed by Marshall Space Flight Center (MSFC) teamed with successful industry partners. MSFC has long been synonymous with human space flight large propulsion programs, engineering acumen and risk intolerance. However, there is a growing portfolio/product line within MSFC that focuses on these smaller, fast paced projects. While launching anything into space is expensive, using a managed risk posture, holding to schedule and keeping costs low by stopping at egood enough f were key elements to their success. Risk is defined as the possibility of loss or failure per Merriam Webster. The National Aeronautics and Space Administration (NASA) defines risk using procedural requirement 8705.4 and establishes eclasses f to discern the acceptable risk per a project. It states a Class D risk has a medium to significant risk of not achieving mission success. MSFC, along with industry partners, has created a niche in Class D efforts. How did the big, cautious MSFC succeed on these projects that embodied the antithesis of its heritage in human space flight? A key factor toward these successful projects was innovative industry partners such as Dynetics Corporation, University of Alabama in Huntsville (UAHuntsville), Johns Hopkins Applied Physics Laboratory (JHU APL), Teledyne Brown Engineering (TBE), Von Braun Center for Science and Innovation (VCSI), SAIC, and Jacobs. Fast Affordable Satellite Technology (FastSat HSV01) is a low earth orbit microsatellite that houses six instruments with the primary scientific objective of earth observation and technology demonstration. The team was comprised of Dynetics, UAHuntsvile, SAIC, Goddard Space Flight Center (GSFC) and VCSI with the United States Air Force Space Test Program as the customer. The team completed design, development, manufacturing, environmental test and integration in

  12. The Efficacy of Self-Paced Study in Multitrial Learning

    Science.gov (United States)

    de Jonge, Mario; Tabbers, Huib K.; Pecher, Diane; Jang, Yoonhee; Zeelenberg, René

    2015-01-01

    In 2 experiments we investigated the efficacy of self-paced study in multitrial learning. In Experiment 1, native speakers of English studied lists of Dutch-English word pairs under 1 of 4 imposed fixed presentation rate conditions (24 × 1 s, 12 × 2 s, 6 × 4 s, or 3 × 8 s) and a self-paced study condition. Total study time per list was equated for…

  13. Factors explaining voluntary participation in PACE-Vaquita

    OpenAIRE

    Sara Avila

    2011-01-01

    Vaquita marina, a small species of porpoise endemic to the Northern Gulf of California in Mexico, is the world’s most endangered cetacean species. With the purpose of preserving vaquita, the Mexican government launched PACE-Vaquita in 2008. This voluntary program offers an innovative schedule of compensations: as in a payment for conservation program, PACE-Vaquita compensates for temporary reductions in fishing reductions in fishing effort; as in a program to accelerate technology adoption,PA...

  14. Pacing in swimming - variability and effects of manipulations

    OpenAIRE

    Skorski, Sabrina

    2015-01-01

    Introduction: In any athletic event, the ability to appropriately distribute energy, is essential to prevent premature fatigue prior to the completion of the event. In sport science literature this is termed ‘pacing’. Within the past decade, research aiming to better understand the underlying mechanisms influencing the selection of an athlete’s pacing during exercise has dramatically increased. It is suggested that pacing is a combination of anticipation, knowledge of the end-point, prior exp...

  15. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    The implantation and sputtering mechanisms which are relevant to ion bombardment of surfaces are described. These are: collision, thermal, electronic and photon-induced sputtering. 135 refs.; 36 figs.; 9 tabs

  16. PACE and the Federal Housing Finance Agency (FHFA)

    Energy Technology Data Exchange (ETDEWEB)

    Zimring, Mark; Fuller, Merrian

    2010-03-17

    The FHFA regulates Fannie Mae, Freddie Mac, and the 12 Federal Home Loan Banks (the government-sponsored enterprises - GSEs). On June 18, 2009, James B. Lockhart III, then Director of FHFA, released a letter expressing concern about the negative impact of energy loan tax assessment programs (ELTAPs) - also known as Property Assessed Clean Energy (PACE) programs - on both the housing finance system and homeowner program participants. Subsequently, a number of PACE proponents responded to the concerns laid out in the FHFA letter. In early Fall 2009, word circulated that FHFA was planning to follow its June letter with guidance to other agencies, possibly including Fannie Mae and Freddie Mac, discouraging them from buying loans on properties subject to PACE-type assessment liens. This triggered a second round of stakeholder letters, several of which were addressed to President Obama. On October 18, 2009, the White House, in what some believe was an attempt to obviate the need for FHFA guidance, released a Policy Framework for PACE Financing Programs that outlined best practices guidance for homeowner and lender protection. As of February 2010, FHFA and the GSEs have agreed to monitor PACE programs and work with stakeholders and the Administration to consider additional guidance beyond the Policy Framework and to collect more information on PACE program efficacy and risks. A summary of the communications timeline and highlights of the communications are provided.

  17. Clinically oriented device programming in bradycardia patients: part 1 (sinus node disease). Proposals from AIAC (Italian Association of Arrhythmology and Cardiac Pacing).

    Science.gov (United States)

    Ziacchi, Matteo; Palmisano, Pietro; Biffi, Mauro; Ricci, Renato P; Landolina, Maurizio; Zoni-Berisso, Massimo; Occhetta, Eraldo; Maglia, Giampiero; Botto, Gianluca; Padeletti, Luigi; Boriani, Giuseppe

    2018-04-01

    : Modern pacemakers have an increasing number of programable parameters and specific algorithms designed to optimize pacing therapy in relation to the individual characteristics of patients. When choosing the most appropriate pacemaker type and programing, the following variables must be taken into account: the type of bradyarrhythmia at the time of pacemaker implantation; the cardiac chamber requiring pacing, and the percentage of pacing actually needed to correct the rhythm disorder; the possible association of multiple rhythm disturbances and conduction diseases; the evolution of conduction disorders during follow-up. The goals of device programing are to preserve or restore the heart rate response to metabolic and hemodynamic demands; to maintain physiological conduction; to maximize device longevity; to detect, prevent, and treat atrial arrhythmia. In patients with sinus node disease, the optimal pacing mode is DDDR. Based on all the available evidence, in this setting, we consider appropriate the activation of the following algorithms: rate responsive function in patients with chronotropic incompetence; algorithms to maximize intrinsic atrioventricular conduction in the absence of atrioventricular blocks; mode-switch algorithms; algorithms for autoadaptive management of the atrial pacing output; algorithms for the prevention and treatment of atrial tachyarrhythmias in the subgroup of patients with atrial tachyarrhythmias/atrial fibrillation. The purpose of this two-part consensus document is to provide specific suggestions (based on an extensive literature review) on appropriate pacemaker setting in relation to patients' clinical features.

  18. Electrical storm in patients with an implanted defibrillator: a matter of definition.

    Science.gov (United States)

    Israel, Carsten W; Barold, S Serge

    2007-10-01

    The term "electrical storm" (ES) indicates a state of cardiac electrical instability manifested by several episodes of ventricular tachyarrhythmias (VTs) within a short time. In patients with an implantable cardioverter defibrillator (ICD), ES is best defined as 3 appropriate VT detections in 24 h, treated by antitachycardia pacing, shock or eventually untreated but sustained in a VT monitoring zone. The number of shocks and inappropriate detections are irrelevant for the definition. ES occurs in approximately 25% of ICD patients within 3 years, with typically 5-55 individual VTs within one storm. Potential triggers can be found in approximately 66% of patients and include new/worsened heart failure, changes in antiarrhythmic medication, context with other illness, psychological stress, diarrhea, and hypokalemia. In most patients, ES consists of monomorphic VT indicating the presence of reentry while ventricular fibrillation indicating acute ischemia is rare. ES seems to have a low immediate mortality (1%) but frequently (50-80%) leads to hospitalization. Long-term prognostic implications of ES are unclear. The key intervention in ES is reduction of the elevated sympathetic tone by beta blockers and frequently benzodiazepines. Amiodarone i.v. has also been successful and azimilide seems promising while class I antiarrhythmic drugs are usually unsuccessful. Substrate mapping and VT ablation may be useful in treatment and prevention of ES. Prevention of ES requires ICD programming systematically avoiding unnecessary shocks (long VT detection, antitachycardia pacing where ever possible) which otherwise can fuel the sympathetic tone and prolong ES.

  19. The Effect of Right Ventricular Apical and Nonapical Pacing on the Short- and Long-Term Changes in Left Ventricular Ejection Fraction: A Systematic Review and Meta-Analysis of Randomized-Controlled Trials.

    Science.gov (United States)

    Hussain, Mohammad Akhtar; Furuya-Kanamori, Luis; Kaye, Gerald; Clark, Justin; Doi, Suhail A R

    2015-09-01

    The right ventricular apex (RVA) is the traditional lead site for chronic pacing but in some patients may cause impaired left ventricular (LV) systolic function over time. Comparisons with right ventricular nonapical (RVNA) pacing sites have generated inconsistent results and recent meta-analyses have demonstrated unclear benefit due to heterogeneity across studies. A systematic search for randomized controlled trials that compared LV ejection fraction (LVEF) outcomes between RVNA and RVA pacing was performed up to October 2014. Twenty-four studies (n = 1,628 patients) met the inclusion criteria. To avoid between study heterogeneity two homogenous groups were created; group 1 where studies reported a difference (in favor of RVNA pacing) and group 2 where studies reported no difference between pacing sites. For group 1, weighted mean difference between RVNA and RVA pacing in terms of LVEF at follow-up was 5.40% (95% confidence interval [CI]: 3.94-6.87), related in part to group one's RVA arm demonstrating a significant reduction (mean loss -3.31%; 95% CI: -6.19 to -0.43) in LVEF between study baseline and end of follow-up. Neither of these finding were seen in group 2. Weighted regression modeling demonstrated that inclusion of poor baseline LVEF (right ventricular pacing where there is inclusion of impaired baseline LVEF (<40%), RVA pacing is associated with deterioration in LV function relative to RVNA pacing. © 2015 Wiley Periodicals, Inc.

  20. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  1. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  2. 42 CFR 460.90 - PACE benefits under Medicare and Medicaid.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false PACE benefits under Medicare and Medicaid. 460.90 Section 460.90 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... FOR THE ELDERLY (PACE) PACE Services § 460.90 PACE benefits under Medicare and Medicaid. If a Medicare...

  3. Analysis of a five year experience of permanent pacemaker implantation at a Nigerian Teaching Hospital: need for a national database

    Science.gov (United States)

    Falase, Bode; Sanusi, Michael; Johnson, Adeyemi; Akinrinlola, Fola; Ajayi, Reina; Oke, David

    2013-01-01

    Introduction Permanent pacemaker implantation is available in Nigeria. There is however no national registry or framework for pacemaker data collection. A pacemaker database has been developed in our institution and the results are analyzed in this study. Methods The study period was between January 2008 and December 2012. Patient data was extracted from a prospectively maintained database which was designed to include the fields of the European pacemaker patient identification code. Results Of the 51 pacemaker implants done, there were 29 males (56.9%) and 22 females (43.1%). Mean age was 68.2±12.7 years. Clinical indications were syncopal attacks in 25 patients (49%), dizzy spells in 15 patients (29.4%), bradycardia with no symptoms in 10 patients (17.7%) and dyspnoea in 2 patients (3.9%). The ECG diagnosis was complete heart block in 27 patients (53%), second degree heart block in 19 patients (37.2%) and sick sinus syndrome with bradycardia in 5 patients (9.8%). Pacemaker modes used were ventricular pacing in 29 patients (56.9%) and dual chamber pacing in 22 patients (43.1%). Files have been closed in 20 patients (39.2%) and 31 patients (60.8%) are still being followed up with median follow up of 26 months, median of 5 visits and 282 pacemaker checks done. Complications seen during follow up were 3 lead displacements (5.9%), 3 pacemaker infections (5.9%), 2 pacemaker pocket erosions (3.9%), and 1 pacemaker related death (2%). There were 5 non-pacemaker related deaths (9.8%). Conclusion Pacemaker data has been maintained for 5 years. We urge other implanting institutions in Nigeria to maintain similar databases and work towards establishment of a national pacemaker registry. PMID:24498465

  4. Endometrial scratching in women with implantation failure after a first IVF/ICSI cycle; does it lead to a higher live birth rate? The SCRaTCH study: A randomized controlled trial (NTR 5342)

    OpenAIRE

    van Hoogenhuijze, N. E.; Torrance, H. L.; Mol, F.; Laven, J. S. E.; Scheenjes, E.; Traas, M. A. F.; Janssen, C.; Cohlen, B.; Teklenburg, G.; de Bruin, J. P.; van Oppenraaij, R.; Maas, J. W. M.; Moll, E.; Fleischer, K.; van Hooff, M. H.

    2017-01-01

    textabstractBackground: Success rates of assisted reproductive techniques (ART) are approximately 30%, with the most important limiting factor being embryo implantation. Mechanical endometrial injury, also called 'scratching', has been proposed to positively affect the chance of implantation after embryo transfer, but the currently available evidence is not yet conclusive. The primary aim of this study is to determine the effect of endometrial scratching prior to a second fresh in vitro ferti...

  5. Diaphragmatic reinnervation in ventilator-dependent patients with cervical spinal cord injury and concomitant phrenic nerve lesions using simultaneous nerve transfers and implantable neurostimulators.

    Science.gov (United States)

    Kaufman, Matthew R; Elkwood, Andrew I; Aboharb, Farid; Cece, John; Brown, David; Rezzadeh, Kameron; Jarrahy, Reza

    2015-06-01

    Patients who are ventilator dependent as a result of combined cervical spinal cord injury and phrenic nerve lesions are generally considered to be unsuitable candidates for diaphragmatic pacing due to loss of phrenic nerve integrity and denervation of the diaphragm. There is limited data regarding efficacy of simultaneous nerve transfers and diaphragmatic pacemakers in the treatment of this patient population. A retrospective review was conducted of 14 consecutive patients with combined lesions of the cervical spinal cord and phrenic nerves, and with complete ventilator dependence, who were treated with simultaneous microsurgical nerve transfer and implantation of diaphragmatic pacemakers. Parameters of interest included time to recovery of diaphragm electromyographic activity, average time pacing without the ventilator, and percent reduction in ventilator dependence. Recovery of diaphragm electromyographic activity was demonstrated in 13 of 14 (93%) patients. Eight of these 13 (62%) patients achieved sustainable periods (> 1 h/d) of ventilator weaning (mean = 10 h/d [n = 8]). Two patients recovered voluntary control of diaphragmatic activity and regained the capacity for spontaneous respiration. The one patient who did not exhibit diaphragmatic reinnervation remains within 12 months of initial treatment. Surgical intervention resulted in a 25% reduction (p nerve transfers and pacemaker implantation can result in reinnervation of the diaphragm and lead to successful ventilator weaning. Our favorable outcomes support consideration of this surgical method for appropriate patients who would otherwise have no alternative therapy to achieve sustained periods of ventilator independence. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Environmental proxies of antigen exposure explain variation in immune investment better than indices of pace of life.

    Science.gov (United States)

    Horrocks, Nicholas P C; Hegemann, Arne; Ostrowski, Stéphane; Ndithia, Henry; Shobrak, Mohammed; Williams, Joseph B; Matson, Kevin D; Tieleman, B I

    2015-01-01

    Investment in immune defences is predicted to covary with a variety of ecologically and evolutionarily relevant axes, with pace of life and environmental antigen exposure being two examples. These axes may themselves covary directly or inversely, and such relationships can lead to conflicting predictions regarding immune investment. If pace of life shapes immune investment then, following life history theory, slow-living, arid zone and tropical species should invest more in immunity than fast-living temperate species. Alternatively, if antigen exposure drives immune investment, then species in antigen-rich tropical and temperate environments are predicted to exhibit higher immune indices than species from antigen-poor arid locations. To test these contrasting predictions we investigated how variation in pace of life and antigen exposure influence immune investment in related lark species (Alaudidae) with differing life histories and predicted risks of exposure to environmental microbes and parasites. We used clutch size and total number of eggs laid per year as indicators of pace of life, and aridity, and the climatic variables that influence aridity, as correlates of antigen abundance. We quantified immune investment by measuring four indices of innate immunity. Pace of life explained little of the variation in immune investment, and only one immune measure correlated significantly with pace of life, but not in the predicted direction. Conversely, aridity, our proxy for environmental antigen exposure, was predictive of immune investment, and larks in more mesic environments had higher immune indices than those living in arid, low-risk locations. Our study suggests that abiotic environmental variables with strong ties to environmental antigen exposure can be important correlates of immunological variation.

  7. Transvenous Lead Extraction via the Inferior Approach Using a Gooseneck Snare versus Simple Manual Traction.

    Science.gov (United States)

    Jo, Uk; Kim, Jun; Hwang, You-Mi; Lee, Ji-Hyun; Kim, Min-Su; Choi, Hyung-Oh; Lee, Woo-Seok; Kwon, Chang-Hee; Ko, Gi-Young; Yoon, Hyun-Ki; Nam, Gi-Byoung; Choi, Kee-Joon; Kim, You-Ho

    2016-03-01

    The number of patients with cardiac implantable electronic devices needing lead extraction is increasing for various reasons, including infections, vascular obstruction, and lead failure. We report our experience with transvenous extraction of pacemaker and defibrillator leads via the inferior approach of using a gooseneck snare as a first-line therapy and compare extraction using a gooseneck snare with extraction using simple manual traction. The study included 23 consecutive patients (43 leads) who underwent transvenous lead extraction using a gooseneck snare (group A) and 10 consecutive patients (17 leads) who underwent lead extraction using simple manual traction (group B). Patient characteristics, indications, and outcomes were analyzed and compared between the groups. The dwelling time of the leads was longer in group A (median, 121) than in group B (median, 56; p=0.000). No differences were noted in the overall procedural success rate (69.6% vs. 70%), clinical procedural success rate (82.6% vs. 90%), and lead clinical success rate (86% vs. 94.1%) between the groups. The procedural success rates according to lead type were 89.2% and 100% for pacing leads and 66.7% and 83.3% for defibrillator leads in groups A and B, respectively. Major complications were noted in 3 (mortality in 1) patients in group A and 2 patients in group B. Transvenous extraction of pacemaker leads via an inferior approach using a gooseneck snare was both safe and effective. However, stand-alone transvenous extraction of defibrillator leads using the inferior approach was suboptimal.

  8. DiPALS: Diaphragm Pacing in patients with Amyotrophic Lateral Sclerosis - a randomised controlled trial.

    Science.gov (United States)

    McDermott, Christopher J; Bradburn, Mike J; Maguire, Chin; Cooper, Cindy L; Baird, Wendy O; Baxter, Susan K; Cohen, Judith; Cantrill, Hannah; Dixon, Simon; Ackroyd, Roger; Baudouin, Simon; Bentley, Andrew; Berrisford, Richard; Bianchi, Stephen; Bourke, Stephen C; Darlison, Roy; Ealing, John; Elliott, Mark; Fitzgerald, Patrick; Galloway, Simon; Hamdalla, Hisham; Hanemann, C Oliver; Hughes, Philip; Imam, Ibrahim; Karat, Dayalan; Leek, Roger; Maynard, Nick; Orrell, Richard W; Sarela, Abeezar; Stradling, John; Talbot, Kevin; Taylor, Lyn; Turner, Martin; Simonds, Anita K; Williams, Tim; Wedzicha, Wisia; Young, Carolyn; Shaw, Pamela J

    2016-06-01

    Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease resulting in death, usually from respiratory failure, within 2-3 years of symptom onset. Non-invasive ventilation (NIV) is a treatment that when given to patients in respiratory failure leads to improved survival and quality of life. Diaphragm pacing (DP), using the NeuRx/4(®) diaphragm pacing system (DPS)™ (Synapse Biomedical, Oberlin, OH, USA), is a new technique that may offer additional or alternative benefits to patients with ALS who are in respiratory failure. The Diaphragm Pacing in patients with Amyotrophic Lateral Sclerosis (DiPALS) trial evaluated the effect of DP on survival over the study duration in patients with ALS with respiratory failure. The DiPALS trial was a multicentre, parallel-group, open-label, randomised controlled trial incorporating health economic analyses and a qualitative longitudinal substudy. Eligible participants had a diagnosis of ALS (ALS laboratory-supported probable, clinically probable or clinically definite according to the World Federation of Neurology revised El Escorial criteria), had been stabilised on riluzole for 30 days, were aged ≥ 18 years and were in respiratory failure. We planned to recruit 108 patients from seven UK-based specialist ALS or respiratory centres. Allocation was performed using 1 : 1 non-deterministic minimisation. Participants were randomised to either standard care (NIV alone) or standard care (NIV) plus DP using the NeuRX/4 DPS. The primary outcome was overall survival, defined as the time from randomisation to death from any cause. Secondary outcomes were patient quality of life [assessed by European Quality of Life-5 Dimensions, three levels (EQ-5D-3L), Short Form questionnaire-36 items and Sleep Apnoea Quality of Life Index questionnaire]; carer quality of life (EQ-5D-3L and Caregiver Burden Inventory); cost-utility analysis and health-care resource use; tolerability and adverse events. Acceptability and attitudes to

  9. Oxford and Cambridge Boat Race: Performance, Pacing and Tactics Between 1890 and 2014.

    Science.gov (United States)

    Edwards, Andrew M; Guy, Joshua H; Hettinga, Florentina J

    2016-10-01

    Currently no studies have examined the historical performances of Oxford and Cambridge Boat Race crews in the context of performance, pacing and tactics which is surprising as the event has routinely taken place annually for over 150 years on the same course. The purpose of this study was twofold, to firstly examine the historical development of performances and physical characteristics of crews over 124 years of the Oxford and Cambridge Boat Race between 1890 and 2014 and secondly to investigate the pacing and tactics employed by crews over that period. Linear regression modelling was applied to investigate the development of performance and body size for crews of eight male individuals over time from Boat Race archive data. Performance change over time was further assessed in 10-year clusters while four intra-race checkpoints were used to examine pacing and tactics. Significant correlations were observed between performance and time (1890-2014) for both Oxford (r = -0.67; p tactical advantage from commencing on either the Surrey or Middlesex station beyond chance alone; however, all crews (n = 228) adopted a fast-start strategy, with 81 % of victories achieved by the crew leading the race at the first intra-race checkpoint (24 % of total distance). Crews leading the race at the final checkpoint (83 % of total distance; 1143 m) achieved victory on 94 % of occasions. Performances and physical characteristics of the crews have changed markedly since 1890, with faster heavier crews now common. Tactically, gaining the early lead position with a fast-start strategy seems particularly meaningful to success in the Boat Race throughout the years, and has been of greater importance to race outcome than factors such as the starting station.

  10. Effect of atrial preference pacing on reducing long-term burden of atrial fibrillation:a clinical study

    International Nuclear Information System (INIS)

    Xu Jianfeng; Chen Yueguang; Su Yangang; Zhang Dadong

    2010-01-01

    Objective: To evaluate the clinical effect of atrial preference pacing (APP) on the prevention of paroxysmal atrial fibrillation. Methods: Based on the type of implanted pacemaker, 46 patients with sick sinus syndrome and paroxysmal atrial fibrillation were divided into two groups. Dual-chamber pacemaker equipped with APP function was implanted in patients of group APP (n=21), while conventional dual-chamber pacemaker was implanted in patients of control group (n=25). The patients were followed up for six months, the maximum P wave duration (Pmax), the P wave dispersion (Pd), the structure of heart chambers, the data of automatic mode switch (AMS) and the total burden of atrial fibrillation were estimated,and the results were statistically analyzed and compared between two groups. Results: The basic clinical characteristics of two groups were comparable. After six months pacing, the difference in Pmax between two groups was of no significance (115.0 ± 10.1 ms vs 122.0 ± 11.0 ms, P > 0.05), while the increase of Pd in control group was more obvious than that in group APP (32.7 ± 4.2 ms vs 20.1 ± 5.3 ms, P 0.05), and also no remarkable difference in the left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV) and left ventricular ejection fraction (LVEF) could be found (P > 0.05). Moreover, no significant difference existed between two groups (P > 0.05). After six months pacing,in group APP the frequencies of AMS decreased more sharply (145 ± 37 times vs 327 ± 13 times, P < 0.05), the duration of AMS shortened more apparently (73 ± 15 hours vs 139 ± 28 hours, P < 0.05) and the total burden of atrial fibrillation was alleviated more obviously (13 ± 5% vs 28 ± 6%, P < 0.05) when compared to those in control group. Conclusion: Atrial preference pacing can coordinate the anisotropy of double atrial depolarization, reduce the frequencies of long-term paroxysmal atrial fibrillation, shorten the duration of atrial fibrillation

  11. Diaphragmatic pacing stimulation in spinal cord injury: anesthetic and perioperative management

    Directory of Open Access Journals (Sweden)

    Miguel L. Tedde

    2012-11-01

    Full Text Available OBJECTIVE: The standard therapy for patients with high-level spinal cord injury is long-term mechanical ventilation through a tracheostomy. However, in some cases, this approach results in death or disability. The aim of this study is to highlight the anesthetics and perioperative aspects of patients undergoing insertion of a diaphragmatic pacemaker. METHODS: Five patients with quadriplegia following high cervical traumatic spinal cord injury and ventilator-dependent chronic respiratory failure were implanted with a laparoscopic diaphragmatic pacemaker after preoperative assessments of their phrenic nerve function and diaphragm contractility through transcutaneous nerve stimulation. ClinicalTrials.gov: NCT01385384. RESULTS: The diaphragmatic pacemaker placement was successful in all of the patients. Two patients presented with capnothorax during the perioperative period, which resolved without consequences. After six months, three patients achieved continuous use of the diaphragm pacing system, and one patient could be removed from mechanical ventilation for more than 4 hours per day. CONCLUSIONS: The implantation of a diaphragmatic phrenic system is a new and safe technique with potential to improve the quality of life of patients who are dependent on mechanical ventilation because of spinal cord injuries. Appropriate indication and adequate perioperative care are fundamental to achieving better results.

  12. The solarPACES strategy for the solar thermal breakthrough

    International Nuclear Information System (INIS)

    Burch, G.D.; Grasse, W.

    1997-01-01

    IEA(International Energy Agency)/SolarPACES(Solar Power and Chemical Energy systems)represents a world wide coalition for information sharing and collaboration on applications of concentrated solar energy. The current SolarPACES community has built up solar thermal system know-how over 15 years, is operating the three main solar test centres in the world. Its main activities are in the following four fields: solar thermal electric power systems, solar chemistry, solar technology and advanced applications and non-technical activities. The article presents the talk on the strategy of solarPACES given at the International Workshop on applied solar energy held in Tashkent(Uzbekistan) in June 1997. (A.A.D.)

  13. Pace: an advanced structure for handling multi-technique NDT

    International Nuclear Information System (INIS)

    Mayos, M.; Guisnel, F.

    1995-08-01

    The growing extent and complexity of NDT data analysis has reached a stage where dedicated systems are required. In the context of a European research program, EDF participated from 1992 to 1994 in one of the first international projects in this field, TRAPPIST and, in 1993, began developing An application for the electricity generating industry, giving rise to the PACE project. The prime objective specially targets the French electricity generating industry, where PACE was to be the reference system for analysis of NDE data concerning EdF power plants. The second objective is to promote the adoption of PACE by other industrial sectors and other countries. The analysis of needs shows that the required system must be designed to analyze data from widely different sources. The PACE entry point consequently has to be a standard format compatible with geometrical data as well as those provided by NDT. The TRAPPIST format constitutes the first version of this standard and is the first step towards European standardization in this respect. Consideration of the different user modes defined for PACE led to the design of a 2-part user structure comprising a database management system (Ingres/Windows 4GL) and a display/processing tool (AVS), also usable to construct analysis scenarios. The structure of PACE is defined nd seems well suited to industrial requirements, but before it is possible to proceed further towards its adoption for actual power plant inspections, it has to be validated on a more realistic application, the eddy current and ultrasonic testing of a full-scale T-joint. This is already under way, whilst work on format standardization and industrialization preparatory procedures are proceeding in parallel. (authors). 4 refs., 6 figs

  14. A protocol for patients with cardiovascular implantable devices undergoing magnetic resonance imaging (MRI): should defibrillation threshold testing be performed post-(MRI).

    Science.gov (United States)

    Burke, Peter Thomas; Ghanbari, Hamid; Alexander, Patrick B; Shaw, Michael K; Daccarett, Marcos; Machado, Christian

    2010-06-01

    Magnetic resonance imaging (MRI) in patients with Cardiovascular Implantable Electronic Devices (CIED) has not been approved by the Food and Drug Administration. Recent data suggests MRI as a relative rather than absolute contraindication in CIED patients. Recently, the American Heart Association has recommended defibrillation threshold testing (DFTT) in implantable cardioverter defibrillator (ICD) patients undergoing MRI. We evaluated the feasibility and safety of a protocol for MRI in CIED patients, incorporating the new recommendations on DFTT. Consecutive patients with CIED undergoing MRI were included. The protocol consisted of continuous monitoring during imaging, device interrogation pre- and post-MRI, reprogramming of the pacemaker to an asynchronous mode in pacemaker-dependent (PMD) patients and a non-tracking/sensing mode for non-PMD patients. All tachyarrhythmia therapies were disabled. Devices were interrogated for lead impedance, battery life, pacing, and sensing thresholds. All patients with ICD underwent DFTT/defibrillator safety margin testing (DSMT) post-MRI. A total of 92 MRI's at 1.5 Tesla were performed in 38 patients. A total of 13 PMD patients, ten ICD patients, four cardiac resynchronization therapy with defibrillator (CRT-D) patients, and 11 non-PMD patients were scanned from four major manufacturers. No device circuitry damage, programming alterations, inappropriate shocks, failure to pace, or changes in sensing, pacing, or defibrillator thresholds were found on single or multiple MRI sessions. Our protocol for MRI in CIED patients appears safe, feasible, and reproducible. This is irrespective of the type of CIED, pacemaker dependancy or multiple 24-h scanning sessions. Our protocol addresses early detection of potential complications and establishes a response system for potential device-related complications. Our observation suggests that routine DFTT/DSMT post-MRI may not be necessary.

  15. Aortic Valve Predilatation with a Small Balloon, without Rapid Pacing, prior to Transfemoral Transcatheter Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Anupama Shivaraju

    2018-01-01

    Full Text Available Objectives. The aim of this study is to assess the feasibility and clinical outcome of transcatheter aortic valve replacement (TAVR using aortic valve predilatation (AVPD with a small, nonocclusive balloon. Background. Balloon aortic valvuloplasty (BAV under rapid pacing is generally performed in TAVR to ensure the passage and sufficient deployment of the prosthesis in the stenotic AV. BAV may cause serious complications, such as left ventricular stunning or cerebrovascular embolism. Methods. A cohort of 50 consecutive patients with severe aortic stenosis underwent transfemoral TAVR with the Edwards Sapien 3-heart valve. All patients underwent AVPD with a small, nonocclusive balloon (12 × 60 or 14 × 60 mm without rapid pacing. Procedural data and clinical outcomes were analyzed. Results. The mean age of the cohort was 81±6 years and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation was 13±9. Crossing the AV and prosthesis implantation was successful in all cases. The postprocedural mean AV gradient was 12±5 mmHg. There were no cases of aortic regurgitation ≥ grade 2. No periprocedural stroke occurred. One patient (2% with chronic atrial fibrillation displayed a transient Wernicke aphasia occurring more than 24 hours after TAVR. Mortality was 0% at 30 days after procedure. Conclusion. In TAVR, AVPD with a small, nonocclusive balloon can be safely performed. By avoiding rapid pacing, this technique may be a valid alternative to traditional BAV. Whether or not the use of APVD without rapid pacing translates into less periprocedural complications needs to be assessed in future studies.

  16. International piping benchmarks: Use of simplified code PACE 2

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, J; Spence, J [University of Strathclyde (United Kingdom); Blundell, C [Risley Nuclear Power Development Establishment, Central Technical Services, Risley, Warrington (United Kingdom)

    1979-06-01

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost. (author)

  17. International piping benchmarks: Use of simplified code PACE 2

    International Nuclear Information System (INIS)

    Boyle, J.; Spence, J.; Blundell, C.

    1979-01-01

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost. (author)

  18. Incidence and predictors of permanent pacemaker implantation following treatment with the repositionable Lotus™ transcatheter aortic valve.

    Science.gov (United States)

    Zaman, Sarah; McCormick, Liam; Gooley, Robert; Rashid, Hashrul; Ramkumar, Satish; Jackson, Damon; Hui, Samuel; Meredith, Ian T

    2017-07-01

    To determine the incidence and predictors of permanent pacemaker (PPM) requirement following transcatheter aortic valve replacement (TAVR) with the mechanically expanded Lotus TM Valve System (Boston Scientific). Pacemaker implantation is the most common complication following TAVR. Predictors of pacing following TAVR with the Lotus valve have not been systematically assessed. Consecutive patients with severe aortic stenosis who underwent Lotus valve implantation were prospectively recruited at a single-centre. Patients with a pre-existing PPM were excluded. Baseline ECG, echocardiographic and multiple detector computed tomography as well as procedural telemetry and depth of implantation were independently analyzed in a blinded manner. The primary endpoint was 30-day incidence of pacemaker requirement (PPM implantation or death while pacing-dependent). Multivariate analysis was performed to identify independent predictors of the primary endpoint. A total of 104 consecutive patients underwent TAVR with the Lotus valve with 9/104 (9%) with a pre-existing PPM excluded. New or worsened procedural LBBB occurred in 78%. Thirty-day incidence of the primary pacing endpoint was 28%. The most common indication for PPM implantation was complete heart block (CHB) (69%). Independent predictors of the primary endpoint included pre-existing RBBB (hazard ratio [HR] 2.8, 95% CI 1.1-7.0; P = 0.032) and depth of implantation below the noncoronary cusp (NCC) (HR 2.4, 95% CI 1.0-5.7; P = 0.045). Almost a third of Lotus valve recipients require pacemaker implantation within 30 days. The presence of pre-existing RBBB and the depth of prosthesis implantation below the NCC were significant pacing predictors. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  19. Surface modifications of dental implants.

    Science.gov (United States)

    Stanford, C M

    2008-06-01

    Dental implant surface technologies have been evolving rapidly to enhance a more rapid bone formation on their surface and hold a potential to increase the predictability of expedited implant therapy. While implant outcomes have become highly predictable, there are sites and conditions that result in elevated implant loss. This paper reviews the impact of macro-retentive features which includes approaches to surface oxide modification, thread design, press-fit and sintered-bead technologies to increase predictability of outcomes. Implant designs that lead to controlled lateral compression of the bone can improve primary stability as long as the stress does not exceed the localized yield strength of the cortical bone. Some implant designs have reduced crestal bone loss by use of multiple cutting threads that are closely spaced, smoothed on the tip but designed to create a hoop-stress stability of the implant as it is completely seated in the osteotomy. Following the placement of the implant, there is a predictable sequence of bone turnover and replacement at the interface that allows the newly formed bone to adapt to microscopic roughness on the implant surface, and on some surfaces, a nanotopography (<10(-9) m scale) that has been shown to preferably influence the formation of bone. Newly emerging studies show that bone cells are exquisitely sensitive to these topographical features and will upregulate the expression of bone related genes for new bone formation when grown on these surfaces. We live in an exciting time of rapid changes in the modalities we can offer patients for tooth replacement therapy. Given this, it is our responsibility to be critical when claims are made, incorporate into our practice what is proven and worthwhile, and to continue to support and provide the best patient care possible.

  20. Pacing in congenital heart disease - A four-decade experience in a single tertiary centre.

    Science.gov (United States)

    Midha, Disha; Chen, Zhong; Jones, David G; Williams, Howell J; Lascelles, Karen; Jarman, Julian; Clague, Jonathan; Till, Janice; Dimopoulos, Konstatinos; Babu-Narayan, Sonya V; Markides, Vias; Gatzoulis, Michael A; Wong, Tom

    2017-08-15

    The increased risk of brady- and tachy-arrhythmias in the congenital heart disease (CHD) population means that cardiac rhythm management devices are often required at an early age and expose patients to device-related complications. The present study drew upon four decades of experience at a tertiary adult congenital heart disease ACHD center and aimed to investigate the indication for cardiac implantable electronic devices (CIEDs) and predictors of late device-related complication requiring re-intervention. A retrospective review of pacing records of ACHD patients over forty years was carried out. The primary outcome measure was device related complication requiring re-intervention. Between 1970 and 2009, 238 structural CHD patients who received CIEDs with follow-up data were identified (structural group). As a comparator group, 98 patients with congenital conduction disease or long QT syndrome with a structurally normal heart (electrical group) were included in the study. During a mean follow-up of 9.6±8.5years, 72 (21%) patients (44 structural group, 28 electrical group) required ≥1 re-intervention due to device related complications. Multivariate analysis showed that age at the time of device implant was an independent predictor of late device-related complications (HR 0.77, 95% CI 0.60-0.98, p=0.04). Sub-analysis of the structural group showed that ACHD complexity (Bethesda guideline) was the only predictor late device-related complication in the structural group (HR 2.96, 95% CI: 1.67-5.26, p<0.01). Increasing age at device implant was inversely associated with late device-related complications. ACHD patients with complex anatomy are at increased risk of device-related complications at mid and long-term follow-up. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  2. LEADING WITH LEADING INDICATORS

    International Nuclear Information System (INIS)

    PREVETTE, S.S.

    2005-01-01

    This paper documents Fluor Hanford's use of Leading Indicators, management leadership, and statistical methodology in order to improve safe performance of work. By applying these methods, Fluor Hanford achieved a significant reduction in injury rates in 2003 and 2004, and the improvement continues today. The integration of data, leadership, and teamwork pays off with improved safety performance and credibility with the customer. The use of Statistical Process Control, Pareto Charts, and Systems Thinking and their effect on management decisions and employee involvement are discussed. Included are practical examples of choosing leading indicators. A statistically based color coded dashboard presentation system methodology is provided. These tools, management theories and methods, coupled with involved leadership and employee efforts, directly led to significant improvements in worker safety and health, and environmental protection and restoration at one of the nation's largest nuclear cleanup sites

  3. Laser annealing of ion implanted silicon

    International Nuclear Information System (INIS)

    White, C.W.; Narayan, J.; Young, R.T.

    1978-11-01

    The physical and electrical properties of ion implanted silicon annealed with high powered ruby laser radiation are summarized. Results show that pulsed laser annealing can lead to a complete removal of extended defects in the implanted region accompanied by incorporation of dopants into lattice sites even when their concentration far exceeds the solid solubility limit

  4. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the rabbit heart.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-01-01

    Ventricular arrhythmias represent one of leading causes for sudden cardiac death, a significant problem in public health. Noninvasive imaging of cardiac electric activities associated with ventricular arrhythmias plays an important role in better our understanding of the mechanisms and optimizing the treatment options. The present study aims to rigorously validate a novel three-dimensional (3-D) cardiac electrical imaging (3-DCEI) technique with the aid of 3-D intra-cardiac mapping during paced rhythm and ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in thirteen healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous norepinephrine (NE). The non-invasively imaged activation sequence correlated well with invasively measured counterparts, with a correlation coefficient of 0.72 and a relative error of 0.30 averaged over all paced beats and NE-induced PVCs and VT beats. The averaged distance from imaged site of initial activation to measured site determined from intra-cardiac mapping was ∼5mm. These promising results suggest that 3-DCEI is feasible to non-invasively localize the origins and image activation sequence of focal ventricular arrhythmias.

  5. MFTF-B PACE tests and final cost report

    International Nuclear Information System (INIS)

    Krause, K.H.; Kozman, T.A.; Smith, J.L.; Horan, R.J.

    1986-10-01

    The Mirror Fusion Test Facility (MFTF-B) construction project was successfully completed in February 1986, with the conclusion of the Plant and Capital Equipment (PACE) Tests. This series of tests, starting in September 1985 and running through February 1986, demonstrated the overall machine capabilities and special facilities accomplishments for the Mirror Fusion Test Facility Project

  6. Self-Paced Physics, Segments 19-23.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Five study segments of the Self-Paced Physics Course materials are presented in this fourth problems and solutions book used as a part of student course work. The subject matter is related to electric charges, insulators, Coulomb's law, electric fields, lines of force, solid angles, conductors, motion of charged particles, dipoles, electric flux,…

  7. The Effects of Self-Paced Blended Learning of Mathematics

    Science.gov (United States)

    Balentyne, Phoebe; Varga, Mary Alice

    2016-01-01

    As online and blended learning gain more popularity in education, it becomes more important to understand their effects on student learning. The purpose of this study was to explore the effects of self-paced blended learning of mathematics on the attitudes and achievement of 26 high ability middle school students, and investigate the relationship…

  8. Hardware packet pacing using a DMA in a parallel computer

    Science.gov (United States)

    Chen, Dong; Heidelberger, Phillip; Vranas, Pavlos

    2013-08-13

    Method and system for hardware packet pacing using a direct memory access controller in a parallel computer which, in one aspect, keeps track of a total number of bytes put on the network as a result of a remote get operation, using a hardware token counter.

  9. PACE: A dynamic programming algorithm for hardware/software partitioning

    DEFF Research Database (Denmark)

    Knudsen, Peter Voigt; Madsen, Jan

    1996-01-01

    This paper presents the PACE partitioning algorithm which is used in the LYCOS co-synthesis system for partitioning control/dataflow graphs into hardware and software parts. The algorithm is a dynamic programming algorithm which solves both the problem of minimizing system execution time...

  10. Self-Paced Physics, Segments 24-27.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Four study segments of the Self-Paced Physics Course materials are presented in this fifth problems and solutions book used as a part of student course work. The subject matter is related to work in electric fields, potential differences, parallel plates, electric potential energies, potential gradients, capacitances, and capacitor circuits.…

  11. PACES: A Model of Student Well-Being

    Science.gov (United States)

    Nelson, Mark D.; Tarabochia, Dawn W.; Koltz, Rebecca L.

    2015-01-01

    School counselors design, deliver, and evaluate comprehensive, developmental school counseling programs that are focused on enhancing student development and success. A model of student well-being, known as PACES, is defined and described that consists of five distinct and interactive domains: physical, affective, cognitive, economic, and social.…

  12. Determination of myocardial energetic output for cardiac rhythm pacing

    Czech Academy of Sciences Publication Activity Database

    Heřman, D.; Převorovská, Světlana; Maršík, František

    2007-01-01

    Roč. 7, č. 4 (2007), s. 156-161 ISSN 1567-8822 R&D Projects: GA ČR GA106/03/1073 Institutional research plan: CEZ:AV0Z20760514 Keywords : heart arrhythmia * cardiac pacing modes * numerical simulation Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery

  13. Keeping Pace with K-12 Online Learning, 2016

    Science.gov (United States)

    Gemin, Butch; Pape, Larry

    2017-01-01

    "Keeping Pace with K-12 Online Learning 2016" marks the thirteenth consecutive year Evergreen has published its annual research of the K-12 education online learning market. The thirteen years of researching, writing and publishing this report represents a time of remarkable change. There has been a constant presence that has become the…

  14. Optimizing Classroom Instruction through Self-Paced Learning Prototype

    Science.gov (United States)

    Bautista, Romiro G.

    2015-01-01

    This study investigated the learning impact of self-paced learning prototype in optimizing classroom instruction towards students' learning in Chemistry. Two sections of 64 Laboratory High School students in Chemistry were used as subjects of the study. The Quasi-Experimental and Correlation Research Design was used in the study: a pre-test was…

  15. Amplitude and phase dynamics associated with acoustically paced finger tapping

    NARCIS (Netherlands)

    Boonstra, T.W.; Daffertshofer, A.; Peper, C.E.; Beek, P.J.

    2006-01-01

    To gain insight into the brain activity associated with the performance of an acoustically paced synchronization task, we analyzed the amplitude and phase dynamics inherent in magnetoencephalographic (MEG) signals across frequency bands in order to discriminate between evoked and induced responses.

  16. Self-Paced Physics, Segments 28-31.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Four study segments of the Self-Paced Physics Course materials are presented in this sixth problems and solutions book used as a part of student course work. The subject matter is related to electric currents, current densities, resistances, Ohm's law, voltages, Joule heating, electromotive forces, single loop circuits, series and parallel…

  17. Introduction to Physics (Mechanics): A Semi-Self Paced Approach.

    Science.gov (United States)

    Schlenker, Richard M.

    Presented is a guide for an introductory college level physics course in mechanics. The course is contract graded and allows students to proceed at their own pace; however, lectures, problem solving sessions, and laboratory sessions are included. Students on an independent basis review video tapes, film loops, library study, and conduct an…

  18. Design Recommendations for Self-Paced Online Faculty Development Courses

    Science.gov (United States)

    Rizzuto, Melissa

    2017-01-01

    An increased need for self-paced, online professional development opportunities in higher education has emerged from a variety of factors including dispersed geographic locations of faculty, full teaching loads, and institutional evaluation requirements. This article is a report of the examination of the design and evaluation of a self-paced…

  19. Self-Paced Physics, Segments 37-40.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Four study segments of the Self-Paced Physics Course materials are presented in this eighth problems and solutions book used as a part of course assignments. The content is related to magnetic induction, Faraday's law, induced currents, Lenz's law, induced electromotive forces, time-varying magnetic fields, self-inductance, inductors,…

  20. Gait Coordination After Stroke: Benefits of Acoustically Paced Treadmill Walking

    NARCIS (Netherlands)

    Roerdink, M.; Lamoth, C.J.C.; Kwakkel, G.; van Wieringen, P.C.W.; Beek, P.J.

    2007-01-01

    Background and Purpose: Gait coordination often is compromised after stroke. The purpose of this study was to evaluate the efficacy of acoustically paced treadmill walking as a method for improving gait coordination in people after stroke. Participants: Ten people after stroke volunteered for the

  1. Gait coordination after stroke: benefits of acoustically paced treadmill walking.

    NARCIS (Netherlands)

    Roerdink, M.; Lamoth, C.J.; Kwakkel, G.; Wieringen, P.C. van; Beek, P.J.

    2007-01-01

    BACKGROUND AND PURPOSE: Gait coordination often is compromised after stroke. The purpose of this study was to evaluate the efficacy of acoustically paced treadmill walking as a method for improving gait coordination in people after stroke. PARTICIPANTS: Ten people after stroke volunteered for the

  2. Bloqueio AV total congênito: novo modelo experimental para avaliação do marcapasso fetal Fetal heart block: a new experimental model to assess fetal pacing

    Directory of Open Access Journals (Sweden)

    Renato S Assad

    1994-09-01

    Full Text Available O implante de marcapasso epicárdíco em fetos via toracotomia é um procedimento potencialmente mais seguro e eficaz para se tratar o bloqueio AV total congênito (BAVT, quando associado à hidropsia fetal e refratário ao tratamento clínico. Este estudo foi desenvolvido com o objetivo de avaliar as características eletrofisiológicas de dois eletrodos epicárdicos através de novo modelo experimental de BAVT congênito induzido pela crioablação do nó AV. Foram aplicados, em 2 grupos de 6 fetos de ovelhas (80% da gestação, um eletrodo de rosqueamento (1,5 voltas e outro de sutura epicárdica. O BAVT foi obtido em todos os fetos, não sendo observado nenhum ritmo de escape ventricular. Os limiares de estimulação foram baixos para ambos os eletrodos, com valores inferiores para o eletrodo de rosqueamento com largura de pulso abaixo de 0,9 mseg (p 0,20 na amplitude da onda R dos 2 eletrodos. O slew rate foi significativamente maior para o grupo de fetos com eletrodo de rosqueamento (1,40 ± 0,2 versus 0,62 ± 0,2 V/seg. p=0,04. O método é simples e reprodutível para avaliação do marcapasso fetal, sendo que o eletrodo de rosqueamento representa a melhor opção, quando houver indicação de implante de marcapasso em fetos.Epicardial fetal pacing via thoracotomy has the potential for being a safer and more reliable procedure to treat congenital complete heart block (CHB associated with fetal hydrops refractory to medical therapy. To assess the acute electrophysiologic characteristics of two ventricular epicardial leads, a new experimental model of fetal heart block induced by cryosurgical ablation of the AV node without the need for fetal cardiac bypass was performed in 12 pregnant ewes at 110-115 days of gestation. A modified screw-in lead (one and a half turn was used in 6 fetal lambs and a stitch-on lead in the other 6 lambs. CHB was achieved in 100% of the fetal lambs, with no ventricular escape rate noticed in any of the lambs

  3. An unusual etiological agent of implantable cardioverter device endocarditis: Corynebacterium mucifaciens

    Directory of Open Access Journals (Sweden)

    Adnan Kaya

    2016-03-01

    Full Text Available Cardiac pacing devices and implantable cardioverter defibrillator (ICD are becoming the mainstay of therapy in cardiology and infective endocarditis (IE and pocket infection; however, these devices require careful monitoring. Here, we describe a case of a 68-year-old female with an ICD presenting with a previously unknown etiological agent of IE, Corynebacterium mucifaciens.

  4. Rhythm perturbations in acoustically paced treadmill walking after stroke.

    Science.gov (United States)

    Roerdink, Melvyn; Lamoth, Claudine J C; van Kordelaar, Joost; Elich, Peter; Konijnenbelt, Manin; Kwakkel, Gert; Beek, Peter J

    2009-09-01

    In rehabilitation, acoustic rhythms are often used to improve gait after stroke. Acoustic cueing may enhance gait coordination by creating a stable coupling between heel strikes and metronome beats and provide a means to train the adaptability of gait coordination to environmental changes, as required in everyday life ambulation. To examine the stability and adaptability of auditory-motor synchronization in acoustically paced treadmill walking in stroke patients. Eleven stroke patients and 10 healthy controls walked on a treadmill at preferred speed and cadence under no metronome, single-metronome (pacing only paretic or nonparetic steps), and double-metronome (pacing both footfalls) conditions. The stability of auditory-motor synchronization was quantified by the variability of the phase relation between footfalls and beats. In a separate session, the acoustic rhythms were perturbed and adaptations to restore auditory-motor synchronization were quantified. For both groups, auditory-motor synchronization was more stable for double-metronome than single-metronome conditions, with stroke patients exhibiting an overall weaker coupling of footfalls to metronome beats than controls. The recovery characteristics following rhythm perturbations corroborated the stability findings and further revealed that stroke patients had difficulty in accelerating their steps and instead preferred a slower-step response to restore synchronization. In gait rehabilitation practice, the use of acoustic rhythms may be more effective when both footfalls are paced. In addition, rhythm perturbations during acoustically paced treadmill walking may not only be employed to evaluate the stability of auditory-motor synchronization but also have promising implications for evaluation and training of gait adaptations in neurorehabilitation practice.

  5. Pacing, Pixels, and Paper: Flexibility in Learning Words from Flashcards

    Directory of Open Access Journals (Sweden)

    Kara Sage

    2016-08-01

    Full Text Available The present study focused on how self-control over pace might help learners successfully extract information from digital learning aids. Past research has indicated that too much control over pace can be overwhelming, but too little control over pace can be ineffective. Within the popular self-testing domain of flashcards, we sought to elucidate the optimal level of user control for digital learning and compare learning outcomes between paper and digital flashcards. College students learned vocabulary from paper flashcards or one of several digital flashcard versions and were scored on their memory recall and asked about their perceptions of the learning process. With digital flashcards, students were randomly assigned to an automatic slideshow of cards with no user control, automatic slideshow with pre-set pauses, automatic slideshow where users could press the spacebar to pause at any time, or a self-paced slideshow with complete user control. Users reported feeling more in control when indeed having some control, but ultimately memory recall, cognitive load, and satisfaction were similar across the five versions. However, memory recall was positively related to user satisfaction with their specific flashcard set, and negatively related to users’ perceived mental effort and difficulty. Notably, whether paper or digital, students showed individual variability in how they advanced through the words. This research adds to the educational literature by suggesting that paper and digital flashcards are equally viable options for students. Given differences between individual users and the connection between satisfaction and recall, individualistic options that offer, but do not force, some control over pace seem ideal. Paper flashcards may already include such options, and e-flashcards should offer similar adaptive features to appeal to a wide variety of users.

  6. Passion and Pacing in Endurance Performance.

    Science.gov (United States)

    Schiphof-Godart, Lieke; Hettinga, Florentina J

    2017-01-01

    Endurance sports are booming, with sports passionates of varying skills and expertise battering city streets and back roads on their weekly or daily exercise rounds. The investments required for performing in endurance exercise are nevertheless considerable, and passion for their sport might explain the efforts endurance athletes are willing to make. Passion may be defined as a strong motivational force and as such might be related to the neurophysiological basis underlying the drive to exercise. A complex relationship between the brain and other systems is responsible for athletes' exercise behavior and thus performance in sports. We anticipate important consequences of athletes' short term choices, for example concerning risk taking actions, on long term outcomes, such as injuries, overtraining and burnout. We propose to consider athletes' type of passion, in combination with neurophysiological parameters, as an explanatory factor inunderstanding the apparent disparity in the regulation of exercise intensity during endurance sports. Previous research has demonstrated that athletes can be passionate toward their sport in either a harmonious or an obsessive way. Although both lead to considerable investments and therefore often to successful performances, obsessive passion may affect athlete well-being and performance on the long run, due to the corresponding inflexible exercise behavior. In this perspective we will thus examine the influence of passion in sport on athletes' short term and long term decision-making and exercise behavior, in particular related to the regulation of exercise intensity, and discuss the expected long term effects of both types of passion for sport.

  7. Tardive Dyskinesia, Oral Parafunction, and Implant-Supported Rehabilitation.

    Science.gov (United States)

    Lumetti, S; Ghiacci, G; Macaluso, G M; Amore, M; Galli, C; Calciolari, E; Manfredi, E

    2016-01-01

    Oral movement disorders may lead to prosthesis and implant failure due to excessive loading. We report on an edentulous patient suffering from drug-induced tardive dyskinesia (TD) and oral parafunction (OP) rehabilitated with implant-supported screw-retained prostheses. The frequency and intensity of the movements were high, and no pharmacological intervention was possible. Moreover, the patient refused night-time splint therapy. A series of implant and prosthetic failures were experienced. Implant failures were all in the maxilla and stopped when a rigid titanium structure was placed to connect implants. Ad hoc designed studies are desirable to elucidate the mutual influence between oral movement disorders and implant-supported rehabilitation.

  8. Association between ventricular pacing and persistent atrial fibrillation in patients indicated to elective pacemaker replacement: Results of the Prefer for Elective Replacement MVP (PreFER MVP) randomized study.

    Science.gov (United States)

    Ricci, Renato P; Botto, Giovanni Luca; Bénézet, Juan M; Nielsen, Jens Cosedis; De Roy, Luc; Piot, Olivier; Quesada, Aurelio; Quaglione, Raffaele; Vaccari, Diego; Mangoni, Lorenza; Grammatico, Andrea; Kozák, Milan

    2015-11-01

    Pacing in the right ventricle can cause a variety of detrimental effects, including atrial tachyarrhythmias (atrial tachycardia [AT]/atrial fibrillation [AF]). The purpose of this study was to evaluate the incidence and predictors of persistent AT/AF in patients with long-term exposure to ventricular pacing. In a multicenter international trial, 605 patients (age 75 ± 11 years, 240 women) referred for replacement of an implanted pacemaker or implantable cardioverter-defibrillator (ICD), with a history of high-percentage (>40%) ventricular pacing, were randomly allocated to standard dual-chamber pacing or managed ventricular pacing (MVP), a pacing modality that minimizes ventricular pacing. The main end-point of this secondary analysis of the PreFER MVP randomized study was persistent AT/AF, defined as ≥7 consecutive days with AT/AF or AT/AF interrupted by atrial cardioversion or AT/AF present during 2 consecutive follow-up visits. Persistent AT/AF was observed in 71 patients (11.7%) after 2 years of follow-up. At multivariable Cox regression analysis, prior AT/AF (hazard ratio [HR] 2.85, 95% confidence interval [CI] 1.20-6.22, P = .017) and ventricular pacing percentage, estimated in the first 3 months, ≥10% (HR 3.24, 95% 95% CI 1.13-9.31, P = .029) were independent predictors for persistent AT/AF. MVP was associated with persistent AT/AF risk (HR 3.41, 95% 95% CI 1.10-10.6, P = .024) in the subgroup of patients with baseline long PR interval (PR >230 ms) but not in the whole population. In pacemaker and ICD replacement patients, a high percentage of ventricular pacing is associated with higher risk of persistent AT/AF. Use of algorithms that minimize right ventricular pacing may benefit patients with normal spontaneous AV conduction but should be evaluated with caution in patients with long PR interval. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  9. System upgrade and its complications in patients with a single lead atrial pacemaker

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Andersen, Henning Rud; Nielsen, Jens Cosedis

    2013-01-01

    To investigate the indications for system upgrade with single lead atrial pacing (AAIR), complications associated with these re-interventions, and possible predictors for system upgrade among patients included in the Danish Multicenter Randomized Trial on AAIR vs. dual-chamber pacing (DDDR) in si...

  10. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  11. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  12. A Fully Implantable Pacemaker for the Mouse: From Battery to Wireless Power

    Science.gov (United States)

    Zellmer, Erik R.; Weinheimer, Carla J.; MacEwan, Matthew R.; Cui, Sophia X.; Nerbonne, Jeanne M.; Efimov, Igor R.

    2013-01-01

    Animal models have become a popular platform for the investigation of the molecular and systemic mechanisms of pathological cardiovascular physiology. Chronic pacing studies with implantable pacemakers in large animals have led to useful models of heart failure and atrial fibrillation. Unfortunately, molecular and genetic studies in these large animal models are often prohibitively expensive or not available. Conversely, the mouse is an excellent species for studying molecular mechanisms of cardiovascular disease through genetic engineering. However, the large size of available pacemakers does not lend itself to chronic pacing in mice. Here, we present the design for a novel, fully implantable wireless-powered pacemaker for mice capable of long-term (>30 days) pacing. This design is compared to a traditional battery-powered pacemaker to demonstrate critical advantages achieved through wireless inductive power transfer and control. Battery-powered and wireless-powered pacemakers were fabricated from standard electronic components in our laboratory. Mice (n = 24) were implanted with endocardial, battery-powered devices (n = 14) and epicardial, wireless-powered devices (n = 10). Wireless-powered devices were associated with reduced implant mortality and more reliable device function compared to battery-powered devices. Eight of 14 (57.1%) mice implanted with battery-powered pacemakers died following device implantation compared to 1 of 10 (10%) mice implanted with wireless-powered pacemakers. Moreover, device function was achieved for 30 days with the wireless-powered device compared to 6 days with the battery-powered device. The wireless-powered pacemaker system presented herein will allow electrophysiology studies in numerous genetically engineered mouse models as well as rapid pacing-induced heart failure and atrial arrhythmia in mice. PMID:24194832

  13. A fully implantable pacemaker for the mouse: from battery to wireless power.

    Science.gov (United States)

    Laughner, Jacob I; Marrus, Scott B; Zellmer, Erik R; Weinheimer, Carla J; MacEwan, Matthew R; Cui, Sophia X; Nerbonne, Jeanne M; Efimov, Igor R

    2013-01-01

    Animal models have become a popular platform for the investigation of the molecular and systemic mechanisms of pathological cardiovascular physiology. Chronic pacing studies with implantable pacemakers in large animals have led to useful models of heart failure and atrial fibrillation. Unfortunately, molecular and genetic studies in these large animal models are often prohibitively expensive or not available. Conversely, the mouse is an excellent species for studying molecular mechanisms of cardiovascular disease through genetic engineering. However, the large size of available pacemakers does not lend itself to chronic pacing in mice. Here, we present the design for a novel, fully implantable wireless-powered pacemaker for mice capable of long-term (>30 days) pacing. This design is compared to a traditional battery-powered pacemaker to demonstrate critical advantages achieved through wireless inductive power transfer and control. Battery-powered and wireless-powered pacemakers were fabricated from standard electronic components in our laboratory. Mice (n = 24) were implanted with endocardial, battery-powered devices (n = 14) and epicardial, wireless-powered devices (n = 10). Wireless-powered devices were associated with reduced implant mortality and more reliable device function compared to battery-powered devices. Eight of 14 (57.1%) mice implanted with battery-powered pacemakers died following device implantation compared to 1 of 10 (10%) mice implanted with wireless-powered pacemakers. Moreover, device function was achieved for 30 days with the wireless-powered device compared to 6 days with the battery-powered device. The wireless-powered pacemaker system presented herein will allow electrophysiology studies in numerous genetically engineered mouse models as well as rapid pacing-induced heart failure and atrial arrhythmia in mice.

  14. A fully implantable pacemaker for the mouse: from battery to wireless power.

    Directory of Open Access Journals (Sweden)

    Jacob I Laughner

    Full Text Available Animal models have become a popular platform for the investigation of the molecular and systemic mechanisms of pathological cardiovascular physiology. Chronic pacing studies with implantable pacemakers in large animals have led to useful models of heart failure and atrial fibrillation. Unfortunately, molecular and genetic studies in these large animal models are often prohibitively expensive or not available. Conversely, the mouse is an excellent species for studying molecular mechanisms of cardiovascular disease through genetic engineering. However, the large size of available pacemakers does not lend itself to chronic pacing in mice. Here, we present the design for a novel, fully implantable wireless-powered pacemaker for mice capable of long-term (>30 days pacing. This design is compared to a traditional battery-powered pacemaker to demonstrate critical advantages achieved through wireless inductive power transfer and control. Battery-powered and wireless-powered pacemakers were fabricated from standard electronic components in our laboratory. Mice (n = 24 were implanted with endocardial, battery-powered devices (n = 14 and epicardial, wireless-powered devices (n = 10. Wireless-powered devices were associated with reduced implant mortality and more reliable device function compared to battery-powered devices. Eight of 14 (57.1% mice implanted with battery-powered pacemakers died following device implantation compared to 1 of 10 (10% mice implanted with wireless-powered pacemakers. Moreover, device function was achieved for 30 days with the wireless-powered device compared to 6 days with the battery-powered device. The wireless-powered pacemaker system presented herein will allow electrophysiology studies in numerous genetically engineered mouse models as well as rapid pacing-induced heart failure and atrial arrhythmia in mice.

  15. Subcutaneous ICD screening with the Boston Scientific ZOOM programmer versus a 12-lead ECG machine.

    Science.gov (United States)

    Chang, Shu C; Patton, Kristen K; Robinson, Melissa R; Poole, Jeanne E; Prutkin, Jordan M

    2018-02-24

    The subcutaneous implantable cardioverter-defibrillator (S-ICD) requires preimplant screening to ensure appropriate sensing and reduce risk of inappropriate shocks. Screening can be performed using either an ICD programmer or a 12-lead electrocardiogram (ECG) machine. It is unclear whether differences in signal filtering and digital sampling change the screening success rate. Subjects were recruited if they had a transvenous single-lead ICD without pacing requirements or were candidates for a new ICD. Screening was performed using both a Boston Scientific ZOOM programmer (Marlborough, MA, USA) and General Electric MAC 5000 ECG machine (Fairfield, CT, USA). A pass was defined as having at least one lead that fit within the screening template in both supine and sitting positions. A total of 69 subjects were included and 27 sets of ECG leads had differing screening results between the two machines (7%). Of these sets, 22 (81%) passed using the ECG machine but failed using the programmer and five (19%) passed using the ECG machine but failed using the programmer (P machine but failed using the programmer. No subject passed screening with the programmer but failed with the ECG machine. There can be occasional disagreement in S-ICD patient screening between an ICD programmer and ECG machine, all of whom passed with the ECG machine but failed using the programmer. On a per lead basis, the ECG machine passes more subjects. It is unknown what the inappropriate shock rate would be if an S-ICD was implanted. Clinical judgment should be used in borderline cases. © 2018 Wiley Periodicals, Inc.

  16. Electrophysiological performance of a bipolar membrane-coated titanium nitride electrode: a randomized comparison of steroid and nonsteroid lead designs.

    Science.gov (United States)

    Wiegand, U K; Zhdanov, A; Stammwitz, E; Crozier, I; Claessens, R J; Meier, J; Bos, R J; Bode, F; Potratz, J

    1999-06-01

    The aim of this multicenter study was to investigate the performance of a new cardiac pacemaker lead with a titanium nitride cathode coated with a copolymer membrane. In particular, the electrophysiological effect of steroid dissolved in this ion-exchange membrane was evaluated by randomized comparison. Ninety-five patients were randomized either to the 1450 T (n = 51) or the 1451 T ventricular lead (n = 45) and received telemeteral VVI(R) pacemakers with identical diagnostic features. Both leads were bipolar, were passively affixed, and had a porous titanium nitride tip with a surface area of 3.5 mm2. The only difference between the two electrodes was 13 micrograms of dexamethasone added to the 1450 Ts membrane coating. Voltage thresholds (VTH) at pulse durations of 0.25, 0.37, and 0.5 ms, lead impedance, and sensing thresholds were measured at discharge, 2 weeks, 1 month, 3 months, and 6 months after implantation. Mean amplitude and the slew rate from three telemetered intracardiac electrograms, chronaxie-rheobase product, and minimum energy consumption were calculated. After a 6-month follow-up, mean voltage thresholds of 0.65 +/- 0.20 V and 0.63 +/- 0.34 were achieved for the 1450 T lead and 1451 T lead, respectively. As a result, a VTH < 1.0 V was obtained in all patients with 1450 T electrodes and in 97.7% of patients with 1451 T leads after 6 months follow-up. In both electrodes, stable VTH was reached 2 weeks after implantation, and no transient rise in threshold was observed. No differences were observed between the steroid and the nonsteroid group in respect to VTH, chronaxie-rheobase product, minimum energy consumption, and potential amplitude and slew rate. In conclusion, safe and efficient pacing at low pulse amplitudes were achieved with both leads. The tip design, independently of the steroid additive, prevented any energy-consuming increases in the voltage threshold.

  17. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  18. Effect of age and performance on pacing of marathon runners

    Directory of Open Access Journals (Sweden)

    Nikolaidis PT

    2017-08-01

    Full Text Available Pantelis Theodoros Nikolaidis,1 Beat Knechtle2,3 1Exercise Physiology Laboratory, Attiki, Greece; 2Gesundheitszentrum St. Gallen, St. Gallen, 3Institute of Primary Care, University of Zurich, Zurich, Switzerland Abstract: Pacing strategies in marathon runners have previously been examined, especially with regard to age and performance level separately. However, less information about the age × performance interaction on pacing in age-group runners exists. The aim of the present study was to examine whether runners with similar race time and at different age differ for pacing. Data (women, n=117,595; men, n=180,487 from the “New York City Marathon” between 2006 and 2016 were analyzed. A between–within subjects analysis of variance showed a large main effect of split on race speed (p<0.001, η2=0.538 with the fastest speed in the 5–10 km split and the slowest in the 35–40 km. A small sex × split interaction on race speed was found (p<0.001, η2=0.035 with men showing larger increase in speed at 5 km and women at 25 km and 40 km (end spurt. An age-group × performance group interaction on Δspeed was shown for both sexes at 5 km, 10 km, 15 km, 20 km, 25 km, 30 km, 35 km, and 40 km (p<0.001, 0.001≤η2≤0.004, where athletes in older age-groups presented a relatively more even pace compared with athletes in younger age-groups, a trend that was more remarkable in the relatively slow performance groups. So far, the present study is the first one to observe an age × performance interaction on pacing; ie, older runners pace differently (smaller changes than younger runners with similar race time. These findings are of great practical interest for coaches working with marathon runners of different age, but similar race time. Keywords: running, master athlete, endurance, aerobic capacity, fatigue, gender, race time

  19. Influence of prosthesis design and implantation technique on implant stresses after cementless revision THR

    Directory of Open Access Journals (Sweden)

    Duda Georg N

    2011-05-01

    Full Text Available Abstract Background Femoral offset influences the forces at the hip and the implant stresses after revision THR. For extended bone defects, these forces may cause considerable bending moments within the implant, possibly leading to implant failure. This study investigates the influences of femoral anteversion and offset on stresses in the Wagner SL revision stem implant under varying extents of bone defect conditions. Methods Wagner SL revision stems with standard (34 mm and increased offset (44 mm were virtually implanted in a model femur with bone defects of variable extent (Paprosky I to IIIb. Variations in surgical technique were simulated by implanting the stems each at 4° or 14° of anteversion. Muscle and joint contact forces were applied to the reconstruction and implant stresses were determined using finite element analyses. Results Whilst increasing the implant's offset by 10 mm led to increased implant stresses (16.7% in peak tensile stresses, altering anteversion played a lesser role (5%. Generally, larger stresses were observed with reduced bone support: implant stresses increased by as much as 59% for a type IIIb defect. With increased offset, the maximum tensile stress was 225 MPa. Conclusion Although increased stresses were observed within the stem with larger offset and increased anteversion, these findings indicate that restoration of offset, key to restoring joint function, is unlikely to result in excessive implant stresses under routine activities if appropriate fixation can be achieved.

  20. Optimal pacing strategy: From theoretical modeling to reality in 1500m speed skating

    NARCIS (Netherlands)

    Hettinga, F.J.; de Koning, J.J.; Schmidt, L.J.I.; Wind, N.A.C.; McIntosh, B.; Foster, C.

    2011-01-01

    Purpose: Athletes are trained to choose the pace which is perceived to be correct during a specific effort, such as the 1500-m speed skating competition. The purpose of the present study was to "override" self-paced (SP) performance by instructing athletes to execute a theoretically optimal pacing

  1. Optimal pacing strategy : from theoretical modelling to reality in 1500-m speed skating

    NARCIS (Netherlands)

    Hettinga, F. J.; De Koning, J. J.; Schmidt, L. J. I.; Wind, N. A. C.; MacIntosh, B. R.; Foster, C.

    Purpose Athletes are trained to choose the pace which is perceived to be correct during a specific effort, such as the 1500-m speed skating competition. The purpose of the present study was to "override" self-paced (SP) performance by instructing athletes to execute a theoretically optimal pacing

  2. Predicting Successful Completion Using Student Delay Indicators in Undergraduate Self-Paced Online Courses

    Science.gov (United States)

    Lim, Janine M.

    2016-01-01

    Self-paced online courses meet flexibility and learning needs of many students, but skepticism persists regarding the quality and the tendency for students to procrastinate in self-paced courses. Research is needed to understand procrastination and delay patterns of students in online self-paced courses to predict successful completion and…

  3. The Key Points of Maintenance Therapy for Dental Implants: A Literature Review.

    Science.gov (United States)

    Pirc, Miha; Dragan, Irina F

    2017-04-01

    Dental implants require lifelong maintenance and care. Success is defined by biologic factors (presence of inflamed soft tissues surrounding dental implants and radiographic changes in the crestal bone levels) and mechanical factors (stability of the implant fixture and implant supported restoration, etc). Most implant failures are initiated by incipient stages of inflammatory processes, which lead to peri-mucositis and peri-implantitis. The evidence regarding the value of maintenance protocol regarding implants is sparse compared with the one for teeth. This article addresses the existing literature on processes for oral hygiene for implant care.

  4. The pace of vocabulary growth helps predict later vocabulary skill

    Science.gov (United States)

    Rowe, Meredith L.; Raudenbush, Stephen W.; Goldin-Meadow, Susan

    2011-01-01

    Children vary widely in the rate at which they acquire words—some start slow and speed up, others start fast and continue at a steady pace. Do early developmental variations of this sort help predict vocabulary skill just prior to kindergarten entry? This longitudinal study starts by examining important predictors (SES, parent input, child gesture) of vocabulary growth between 14 and 46 months (n=62), and then uses growth estimates to predict children's vocabulary at 54 months. Velocity and acceleration in vocabulary development at 30 months predicted later vocabulary, particularly for children from low socioeconomic backgrounds. Understanding the pace of early vocabulary growth thus improves our ability to predict school readiness, and may help identify children at risk for starting behind. PMID:22235920

  5. Pacemaker implantation after catheter ablation for atrial fibrillation.

    Science.gov (United States)

    Deshmukh, Abhishek J; Yao, Xiaoxi; Schilz, Stephanie; Van Houten, Holly; Sangaralingham, Lindsey R; Asirvatham, Samuel J; Friedman, Paul A; Packer, Douglas L; Noseworthy, Peter A

    2016-01-01

    Sinus node dysfunction requiring pacemaker implantation is commonly associated with atrial fibrillation (AF), but may not be clinically apparent until restoration of sinus rhythm with ablation or cardioversion. We sought to determine frequency, time course, and predictors for pacemaker implantation after catheter ablation, and to compare the overall rates to a matched cardioversion cohort. We conducted a retrospective analysis using a large US commercial insurance database and identified 12,158 AF patients who underwent catheter ablation between January 1, 2005 and December 31, 2012. Over an average of 2.4 years of follow-up, 5.6 % of the patients underwent pacemaker implantation. Using the Cox proportional hazards models, we found that risk of risks of pacemaker implantation was associated with older age (50-64 and ≥65 versus pacemaker implantation between ablation patients and propensity score (PS)-matched cardioversion groups (3.5 versus. 4.1 % at 1 year and 8.8 versus 8.3 % at 5 years). Overall, pacemaker implantation occurs in about 1/28 patients within 1 year of catheter ablation. The overall implantation rate decreased between 2005 and 2012. Furthermore, the risk after ablation is similar to cardioversion, suggesting that patients require pacing due to a common underlying electrophysiologic substrate, rather than the ablation itself.

  6. Organizational Learning: Keeping Pace with Change through Action Learning

    OpenAIRE

    Yeadon-Lee, Annie

    2015-01-01

    In the current climate of economic ‘austerity’, organisational learning has increasingly gained importance, and a need for new ways of transferring learning has been identified. Organisational learning is seen as key to organisational success, ensuring both competitive advantage and organisational longevity. However, in order for organisations to keep pace with change they must not only strive to learn but also pay attention to how they might learn. A dominant view within the field of organis...

  7. The learning curve associated with the introduction of the subcutaneous implantable defibrillator

    NARCIS (Netherlands)

    Knops, Reinoud E.; Brouwer, Tom F.; Barr, Craig S.; Theuns, Dominic A.; Boersma, Lucas; Weiss, Raul; Neuzil, Petr; Scholten, Marcoen; Lambiase, Pier D.; Leon, Angel R.; Hood, Margaret; Jones, Paul W.; Wold, Nicholas; Grace, Andrew A.; Olde Nordkamp, Louise R. A.; Burke, Martin C.

    2016-01-01

    Aims The subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced to overcome complications related to transvenous leads. Adoption of the S-ICD requires implanters to learn a new implantation technique. The aim of this study was to assess the learning curve for S-ICD implanters

  8. Factors affecting the regulation of pacing: current perspectives

    Directory of Open Access Journals (Sweden)

    Mauger AR

    2014-09-01

    Full Text Available Alexis R Mauger Endurance Research Group, School of Sport and Exercise Sciences, Faculty of Science, University of Kent, Chatham, UK Abstract: During prolonged dynamic and rhythmic exercise, muscular pain and discomfort arises as a result of an increased concentration of deleterious metabolites. Sensed by peripheral nociceptors and transmitted via afferent feedback to the brain, this provides important information regarding the physiological state of the muscle. These sensations ultimately contribute to what is termed "exercise-induced pain". Despite being well recognized by athletes and coaches, and suggested to be integral to exercise performance, this construct has largely escaped attention in experimental work. This perspective article highlights the current understanding of pacing in endurance performance, and the causes of exercise-induced pain. A new perspective is described, which proposes how exercise-induced pain may be a contributing factor in helping individuals to regulate their work rate during exercise and thus provides an important construct in pacing. Keywords: pain, exercise-induced pain, discomfort, exercise performance, self-paced

  9. MRI with cardiac pacing devices – Safety in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Kaasalainen, Touko, E-mail: touko.kaasalainen@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Department of Physics, University of Helsinki (Finland); Pakarinen, Sami, E-mail: sami.pakarinen@hus.fi [HUS Department of Cardiology, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Kivistö, Sari, E-mail: sari.kivisto@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Holmström, Miia, E-mail: miia.holmstrom@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Hänninen, Helena, E-mail: helena.hanninen@hus.fi [HUS Department of Cardiology, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Peltonen, Juha, E-mail: juha.peltonen@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Department of Biomedical Engineering and Computational Science, School of Science, Aalto University, Helsinki (Finland); Lauerma, Kirsi, E-mail: kirsi.lauerma@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Sipilä, Outi, E-mail: outi.sipila@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland)

    2014-08-15

    Objectives: The aim of this study was to introduce a single centre “real life” experience of performing MRI examinations in clinical practice on patients with cardiac pacemaker systems. Additionally, we aimed to evaluate the safety of using a dedicated safety protocol for these patients. Materials and methods: We used a 1.5 T MRI scanner to conduct 68 MRI scans of different body regions in patients with pacing systems. Of the cardiac devices, 32% were MR-conditional, whereas the remaining 68% were MR-unsafe. We recorded the functional parameters of the devices prior, immediately after, and approximately one month after the MRI scanning, and compared the device parameters to the baseline values. Results: All MRI examinations were completed safely, and each device could be interrogated normally following the MRI. We observed no changes in the programmed parameters of the devices. For most of the participants, the distributions of the immediate and one-month changes in the device parameters were within 20% of the baseline values, although some changes approached clinically important thresholds. Furthermore, we observed no differences in the variable changes between MR-conditional and MR-unsafe pacing systems, or between scans of the thorax area and other scanned areas. Conclusion: MRI in patients with MR-conditional pacing systems and selected MR-unsafe systems could be performed safely under strict conditions in this study.

  10. Optimizing classroom instruction through self-paced learning prototype

    Directory of Open Access Journals (Sweden)

    Romiro Gordo Bautista

    2015-09-01

    Full Text Available This study investigated the learning impact of self-paced learning prototype in optimizing classroom instruction towards students’ learning in Chemistry. Two sections of 64 Laboratory High School students in Chemistry were used as subjects of the study. The Quasi-Experimental and Correlation Research Design was used in the study: a pre-test was conducted, scored and analyzed which served as the basis in determining the initial learning schema of the respondents. A questionnaire was adopted to find the learning motivation of the students in science. Using Pearson-r correlation, it was found out that there is a highly significant relationship between their internal drive and their academic performance. Moreover, a post-test was conducted after self-paced learning prototype was used in the development of select topics in their curricular plot. It was found out that the students who experienced the self-paced learning prototype performed better in their academic performance as evidenced by the difference of their mean post-test results. ANCOVA results on the post-test mean scores of the respondents were utilized in establishing the causal-effect of the learning prototype to the academic performance of the students in Chemistry. A highly significant effect on their academic performance (R-square value of 70.7% and significant interaction of the models to the experimental grouping and mental abilities of the respondents are concluded in the study.

  11. Unilateral Laryngeal Pacing System and Its Functional Evaluation

    Directory of Open Access Journals (Sweden)

    Taiping Zeng

    2017-01-01

    Full Text Available Goal. To establish a reliable instrumental system for synchronized reactivation of a unilaterally paralyzed vocal fold and evaluate its functional feasibility. Methods. Unilateral vocal fold paralysis model was induced by destruction of the left recurrent laryngeal nerve (RLN in anesthetized dogs. With a micro controller-based electronic system, electromyography (EMG signals from cricothyroid (CT muscle on the ipsilateral side were recorded and used to trigger pacing of paralyzed vocalis muscles. The dynamic movement of vocal folds was continuously monitored using an endoscope, and the opening and closing of the glottis were quantified with customized imaging processing software. Results. The recorded video images showed that left side vocal fold was obviously paralyzed after destructing the RLN. Using the pacing system with feedback triggering EMG signals from the ipsilateral CT muscle, the paralyzed vocal fold was successfully reactivated, and its movement was shown to be synchronized with the healthy side. Significance. The developed unilateral laryngeal pacing system triggered by EMG from the ipsilateral side CT muscle could be successfully used in unilateral vocal fold paralysis with the advantage of avoiding disturbance to the healthy side muscles.

  12. Pacing and awareness: brain regulation of physical activity.

    Science.gov (United States)

    Edwards, A M; Polman, R C J

    2013-11-01

    The aim of this current opinion article is to provide a contemporary perspective on the role of brain regulatory control of paced performances in response to exercise challenges. There has been considerable recent conjecture as to the role of the brain during exercise, and it is now broadly accepted that fatigue does not occur without brain involvement and that all voluntary activity is likely to be paced at some level by the brain according to individualised priorities and knowledge of personal capabilities. This article examines the role of pacing in managing and distributing effort to successfully accomplish physical tasks, while extending existing theories on the role of the brain as a central controller of performance. The opinion proposed in this article is that a central regulator operates to control exercise performance but achieves this without the requirement of an intelligent central governor located in the subconscious brain. It seems likely that brain regulation operates at different levels of awareness, such that minor homeostatic challenges are addressed automatically without conscious awareness, while larger metabolic disturbances attract conscious awareness and evoke a behavioural response. This supports the view that the brain regulates exercise performance but that the interpretation of the mechanisms underlying this effect have not yet been fully elucidated.

  13. Novel Insights into Structure-Activity Relationships of N-Terminally Modified PACE4 Inhibitors.

    Science.gov (United States)

    Kwiatkowska, Anna; Couture, Frédéric; Levesque, Christine; Ly, Kévin; Beauchemin, Sophie; Desjardins, Roxane; Neugebauer, Witold; Dory, Yves L; Day, Robert

    2016-02-04

    PACE4 plays important roles in prostate cancer cell proliferation. The inhibition of this enzyme has been shown to slow prostate cancer progression and is emerging as a promising therapeutic strategy. In previous work, we developed a highly potent and selective PACE4 inhibitor, the multi-Leu (ML) peptide, an octapeptide with the sequence Ac-LLLLRVKR-NH2 . Here, with the objective of developing a useful compound for in vivo administration, we investigate the effect of N-terminal modifications. The inhibitory activity, toxicity, stability, and cell penetration properties of the resulting analogues were studied and compared to the unmodified inhibitor. Our results show that the incorporation of a polyethylene glycol (PEG) moiety leads to a loss of antiproliferative activity, whereas the attachment of a lipid chain preserves or improves it. However, the lipidated peptides are significantly more toxic when compared with their unmodified counterparts. Therefore, the best results were achieved not by the N-terminal extension but by the protection of both ends with the d-Leu residue and 4-amidinobenzylamide, which yielded the most stable inhibitor, with an excellent activity and toxicity profile. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Ion implantation of boron in germanium

    International Nuclear Information System (INIS)

    Jones, K.S.

    1985-05-01

    Ion implantation of 11 B + into room temperature Ge samples leads to a p-type layer prior to any post implant annealing steps. Variable temperature Hall measurements and deep level transient spectroscopy experiments indicate that room temperature implantation of 11 B + into Ge results in 100% of the boron ions being electrically active as shallow acceptor, over the entire dose range (5 x 10 11 /cm 2 to 1 x 10 14 /cm 2 ) and energy range (25 keV to 100 keV) investigated, without any post implant annealing. The concentration of damage related acceptor centers is only 10% of the boron related, shallow acceptor center concentration for low energy implants (25 keV), but becomes dominant at high energies (100 keV) and low doses ( 12 /cm 2 ). Three damage related hole traps are produced by ion implantation of 11 B + . Two of these hole traps have also been observed in γ-irradiated Ge and may be oxygen-vacancy related defects, while the third trap may be divacancy related. All three traps anneal out at low temperatures ( 0 C). Boron, from room temperature implantation of BF 2 + into Ge, is not substitutionally active prior to a post implant annealing step of 250 0 C for 30 minutes. After annealing additional shallow acceptors are observed in BF 2 + implanted samples which may be due to fluorine or flourine related complexes which are electrically active

  15. Feedback to providers improves evidence-based implantable cardioverter-defibrillator programming and reduces shocks.

    Science.gov (United States)

    Silver, Marc T; Sterns, Laurence D; Piccini, Jonathan P; Joung, Boyoung; Ching, Chi-Keong; Pickett, Robert A; Rabinovich, Rafael; Liu, Shufeng; Peterson, Brett J; Lexcen, Daniel R

    2015-03-01

    Implantable cardioverter-defibrillator (ICD) shocks are associated with increased anxiety, health care utilization, and potentially mortality. The purpose of the Shock-Less Study was to determine if providing feedback reports to physicians on their adherence to evidence-based shock reduction programming could improve their programming behavior and reduce shocks. Shock-Less enrolled primary prevention (PP) and secondary prevention (SP) ICD patients between 2009 and 2012 at 118 study centers worldwide and followed patients longitudinally after their ICD implant. Center-specific therapy programming reports (TPRs) were delivered to each center 9 to 12 months after their first enrollment. The reports detailed adherence to evidence-based programming targets: number of intervals to detect ventricular fibrillation (VF NID), longest treatment interval (LTI), supraventricular tachycardia (SVT) discriminators (Wavelet, PR Logic), SVT limit, Lead Integrity Alert (LIA), and antitachycardia pacing (ATP). Clinicians programmed ICDs at their discretion. The primary outcome measure was the change in utilization of evidence-based shock reduction programming before (phase I, n = 2694 patients) and after initiation of the TPR (phase II, n = 1438 patients). Patients implanted after feedback reports (phase II) were up to 20% more likely to have their ICDs programmed in line with evidence-based shock reduction programming (eg, VF NID in PP patients 30/40 in 33.5% vs 18.6%, P programming feedback reports improves adherence to evidence-based shock reduction programming and is associated with lower risk of ICD shocks. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  16. Pacemaker Use in New Zealand - Data From the New Zealand Implanted Cardiac Device Registry (ANZACS-QI 15).

    Science.gov (United States)

    Larsen, P D; Kerr, A J; Hood, M; Harding, S A; Hooks, D; Heaven, D; Lever, N A; Sinclair, S; Boddington, D; Tang, E W; Swampillai, J; Stiles, M K

    2017-03-01

    The New Zealand Cardiac Implanted Device Registry (Device) has recently been developed under the auspices of the New Zealand Branch of the Cardiac Society of Australia and New Zealand. This study describes the initial Device registry cohort of patients receiving a new pacemaker, their indications for pacing and their perioperative complications. The Device Registry was used to audit patients receiving a first pacemaker between 1 st January 2014 and 1 st June 2015. We examined 1611 patients undergoing first pacemaker implantation. Patients were predominantly male (59%), and had a median age of 70 years. The most common symptom for pacemaker implantation was syncope (39%), followed by dizziness (30%) and dyspnoea (12%). The most common aetiology for a pacemaker was a conduction tissue disorder (35%), followed by sinus node dysfunction (22%). Atrioventricular (AV) block was the most common ECG abnormality, present in 44%. Dual chamber pacemakers were most common (62%), followed by single chamber ventricular pacemakers (34%), and cardiac resynchronisation therapy - pacemakers (CRT-P) (2%). Complications within 24hours of the implant procedure were reported in 64 patients (3.9%), none of which were fatal. The most common complication was the need for reoperation to manipulate a lead, occurring in 23 patients (1.4%). This is the first description of data entered into the Device registry. Patients receiving a pacemaker were younger than in European registries, and there was a low use of CRT-P devices compared to international rates. Complications rates were low and compare favourably to available international data. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  17. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  18. Endometrial scratching in women with implantation failure after a first IVF/ICSI cycle; does it lead to a higher live birth rate? The SCRaTCH study: a randomized controlled trial (NTR 5342).

    Science.gov (United States)

    van Hoogenhuijze, N E; Torrance, H L; Mol, F; Laven, J S E; Scheenjes, E; Traas, M A F; Janssen, C; Cohlen, B; Teklenburg, G; de Bruin, J P; van Oppenraaij, R; Maas, J W M; Moll, E; Fleischer, K; van Hooff, M H; de Koning, C; Cantineau, A; Lambalk, C B; Verberg, M; Nijs, M; Manger, A P; van Rumste, M; van der Voet, L F; Preys-Bosman, A; Visser, J; Brinkhuis, E; den Hartog, J E; Sluijmer, A; Jansen, F W; Hermes, W; Bandell, M L; Pelinck, M J; van Disseldorp, J; van Wely, M; Smeenk, J; Pieterse, Q D; Boxmeer, J C; Groenewoud, E R; Eijkemans, M J C; Kasius, J C; Broekmans, F J M

    2017-07-21

    Success rates of assisted reproductive techniques (ART) are approximately 30%, with the most important limiting factor being embryo implantation. Mechanical endometrial injury, also called 'scratching', has been proposed to positively affect the chance of implantation after embryo transfer, but the currently available evidence is not yet conclusive. The primary aim of this study is to determine the effect of endometrial scratching prior to a second fresh in vitro fertilization/intracytoplasmic sperm injection (IVF/ICSI) cycle on live birth rates in women with a failed first IVF/ICSI cycle. Multicenter randomized controlled trial in Dutch academic and non-academic hospitals. A total of 900 women will be included of whom half will undergo an endometrial scratch in the luteal phase of the cycle prior to controlled ovarian hyperstimulation using an endometrial biopsy catheter. The primary endpoint is the live birth rate after the 2 nd fresh IVF/ICSI cycle. Secondary endpoints are costs, cumulative live birth rate (after the full 2 nd IVF/ICSI cycle and over 12 months of follow-up); clinical and ongoing pregnancy rate; multiple pregnancy rate; miscarriage rate and endometrial tissue parameters associated with implantation failure. Multiple studies have been performed to investigate the effect of endometrial scratching on live birth rates in women undergoing IVF/ICSI cycles. Due to heterogeneity in both the method and population being scratched, it remains unclear which group of women will benefit from the procedure. The SCRaTCH trial proposed here aims to investigate the effect of endometrial scratching prior to controlled ovarian hyperstimulation in a large group of women undergoing a second IVF/ICSI cycle. NTR 5342 , registered July 31 st , 2015. Version 4.10, January 4th, 2017.

  19. [Diaphragm pacing for the ventilatory support of the quadriplegic patients with respiratory paralysis].

    Science.gov (United States)

    Cheng, H; Wang, L S; Pan, H C; Shoung, H M; Lee, L S

    1992-02-01

    Electrical stimulation of the phrenic nerve to pace the diaphragm in patients with chronic ventilatory insufficiency has been an established therapeutic modality since William W.L. Glenn first described using radiofrequency signals in 1978 to stimulate the phrenic nerves. Before this event, patients who were ventilator-dependent and thus bedridden because of respiratory paralysis associated with quadriplegia usually anticipated little chance for physical or psychosocial rehabilitation. Two cases of C1-C2 subluxtion with cord injury and chronic ventilatory insufficiency were implanted at VGH-Taipei with diaphragm pacemaker in 1988. Postoperative phrenic nerve stimulation was given according to individual training schedule. One case with total phrenic paralysis received bilateral phrenic nerve stimulation and became weaned from the ventilator 6 months later. The other case with partially active ventilatory function received unilateral phrenic nerve stimulation to compensate the ventilation. However, its final outcome still showed the necessity of a bilateral mode to achieve adequate ventilation irrespective of strenuous training for 2 years.

  20. Composite fibrous glaucoma drainage implant

    Science.gov (United States)

    Klapstova, A.; Horakova, J.; Shynkarenko, A.; Lukas, D.

    2017-10-01

    Glaucoma is a frequent reason of loss vision. It is usually caused by increased intraocular pressure leading to damage of optic nerve head. This work deals with the development of fibrous structure suitable for glaucoma drainage implants (GDI). Commercially produced metallic glaucoma implants are very effective in lowering intraocular pressure. However, these implants may cause adverse events such as damage to adjacent tissue, fibrosis, hypotony or many others [1]. The aim of this study is to reduce undesirable properties of currently produced drains and improve their properties by creating of the composite fibrous drain for achieve a normal intraocular pressure. Two types of electrospinning technologies were used for the production of very small tubular implants. First type was focused for production of outer part of tubular drain and the second type of electrospinning method made the inner part of shape follows the connections of both parts. Complete implant had a special properties suitable for drainage of fluid. Morphological parameters, liquid transport tests and in-vitro cell adhesion tests were detected.

  1. Capacitive Feedthroughs for Medical Implants.

    Science.gov (United States)

    Grob, Sven; Tass, Peter A; Hauptmann, Christian

    2016-01-01

    Important technological advances in the last decades paved the road to a great success story for electrically stimulating medical implants, including cochlear implants or implants for deep brain stimulation. However, there are still many challenges in reducing side effects and improving functionality and comfort for the patient. Two of the main challenges are the wish for smaller implants on one hand, and the demand for more stimulation channels on the other hand. But these two aims lead to a conflict of interests. This paper presents a novel design for an electrical feedthrough, the so called capacitive feedthrough, which allows both reducing the size, and increasing the number of included channels. Capacitive feedthroughs combine the functionality of a coupling capacitor and an electrical feedthrough within one and the same structure. The paper also discusses the progress and the challenges of the first produced demonstrators. The concept bears a high potential in improving current feedthrough technology, and could be applied on all kinds of electrical medical implants, even if its implementation might be challenging.

  2. Individual titanium zygomatic implant

    Science.gov (United States)

    Nekhoroshev, M. V.; Ryabov, K. N.; Avdeev, E. V.

    2018-03-01

    Custom individual implants for the reconstruction of craniofacial defects have gained importance due to better qualitative characteristics over their generic counterparts – plates, which should be bent according to patient needs. The Additive Manufacturing of individual implants allows reducing cost and improving quality of implants. In this paper, the authors describe design of zygomatic implant models based on computed tomography (CT) data. The fabrication of the implants will be carried out with 3D printing by selective laser melting machine SLM 280HL.

  3. Lead poisoning

    Science.gov (United States)

    ... drinking water in homes containing pipes that were connected with lead solder . Although new building codes require ... lead in their bodies when they put lead objects in their mouths, especially if they swallow those ...

  4. Lead Poisoning

    Science.gov (United States)

    Lead is a metal that occurs naturally in the earth's crust. Lead can be found in all parts of our ... from human activities such as mining and manufacturing. Lead used to be in paint; older houses may ...

  5. Cardiac resynchronization therapy with His bundle pacing as a method of treatment of chronic heart failure in patients with permanent atrial fibrillation and left bundle branch block.

    Science.gov (United States)

    Boczar, Krzysztof; Sławuta, Agnieszka; Ząbek, Andrzej; Dębski, Maciej; Gajek, Jacek; Lelakowski, Jacek; Małecka, Barbara

    CRT is a therapeutic option for patients with heart failure, sinus rhythm, prolonged QRS complex duration and reduced ejection fraction. We present a case of 71-year-old woman with dilated cardiomyopathy, NYHA functional class III and AF. We implanted CRT combined with direct His-bundle pacing. The indication for such a therapy was a left bundle branch block with a QRS complex of 178ms and a left ventricular EF of 15%, left ventricular end-diastolic diameter (LVEDD) of 75mm. After 8months of follow-up the LVEDD was 60mm with EF 35-40%. Copyright © 2017. Published by Elsevier Inc.

  6. New orthopaedic implant management tool for computer-assisted planning, navigation, and simulation: from implant CAD files to a standardized XML-based implant database.

    Science.gov (United States)

    Sagbo, S; Blochaou, F; Langlotz, F; Vangenot, C; Nolte, L-P; Zheng, G

    2005-01-01

    Computer-Assisted Orthopaedic Surgery (CAOS) has made much progress over the last 10 years. Navigation systems have been recognized as important tools that help surgeons, and various such systems have been developed. A disadvantage of these systems is that they use non-standard formalisms and techniques. As a result, there are no standard concepts for implant and tool management or data formats to store information for use in 3D planning and navigation. We addressed these limitations and developed a practical and generic solution that offers benefits for surgeons, implant manufacturers, and CAS application developers. We developed a virtual implant database containing geometrical as well as calibration information for orthopedic implants and instruments, with a focus on trauma. This database has been successfully tested for various applications in the client/server mode. The implant information is not static, however, because manufacturers periodically revise their implants, resulting in the deletion of some implants and the introduction of new ones. Tracking these continuous changes and keeping CAS systems up to date is a tedious task if done manually. This leads to additional costs for system development, and some errors are inevitably generated due to the huge amount of information that has to be processed. To ease management with respect to implant life cycle, we developed a tool to assist end-users (surgeons, hospitals, CAS system providers, and implant manufacturers) in managing their implants. Our system can be used for pre-operative planning and intra-operative navigation, and also for any surgical simulation involving orthopedic implants. Currently, this tool allows addition of new implants, modification of existing ones, deletion of obsolete implants, export of a given implant, and also creation of backups. Our implant management system has been successfully tested in the laboratory with very promising results. It makes it possible to fill the current gap

  7. Standardized programming to reduce the burden of inappropriate therapies in implantable cardioverter defibrillators - Single centre follow up results

    Directory of Open Access Journals (Sweden)

    U. Boles

    2018-03-01

    Full Text Available Background: Current algorithms and device morphology templates have been proposed in current Implantable Cardioverter-Defibrillators (ICDs to minimize inappropriate therapies (ITS, but this has not been completely successful. Aim: Assess the impact of a deliberate strategy of using an atrial lead implant with standardized parameters; based on all current ICD discriminators and technologies, on the burden of ITS. Method: A retrospective single-centre analysis of 250 patients with either dual chamber (DR ICDs or biventricular ICDs (CRTDs over a (41.9 ± 27.3 month period was performed. The incidence of ITS on all ICD and CRTD patients was chronicled after the implementation of standardized programming. Results: 39 events of anti-tachycardial pacing (ATP and/or shocks were identified in 20 patients (8% incidence rate among patients. The total number of individual therapies was 120, of which 34% were inappropriate ATP, and 36% were inappropriate shocks. 11 patients of the 250 patients received ITS (4.4%. Of the 20 patients, four had ICDs for primary prevention and 16 for a secondary prevention. All the episodes in the primary indication group were inappropriate, while seven patients (43% of the secondary indication group experienced inappropriate therapies. Conclusions: The burden of ITS in the population of patients receiving ICDs was 4.4% in the presence of atrial leads. The proposed rationalized programming criteria seems an effective strategy to minimize the burden of inappropriate therapies and will require further validation. Keywords: Implantable cardioverter-defibrillator (ICDs, Inappropriate therapies, Standardized programming

  8. HEART ELECTRICAL AXIS Α ANGLE VALUES DISTRIBUTION IN PATIENTS, UNDERGOING PERMANENT PACEMAKER IMPLANTATION

    Directory of Open Access Journals (Sweden)

    O. S. Voronenko

    2016-06-01

    Full Text Available 52 patients (24 male and 28 female aged 71 ± 8 years, underwent permanent pacemaker implantation were included in the study. Analysis of heart electrical axis (HEA α angle values distribution was carried out in three dimensions in patience before and after pacemaker (PM implantation. The data processed in Microsoft Excel with calculation of the average and it’s standard deviation. Significance of differences in data before and after PM implantation was assessed using Friedman ANOVA test and Kendall concordance coefficient. It was found, that α angle values distribution in patients with implanted PM is transformed from a unimodal to bimodal on the permanent cardiac pacing background. It’s assumed, that α angle changes resulting due to right ventricular electrode positioning options during PM implantation. Clarification of the nature of this change requires a special study.

  9. Biventricular / Left Ventricular Pacing in Hypertrophic Obstructive Cardiomyopathy: An Overview

    Directory of Open Access Journals (Sweden)

    Radu Vatasescu, MD

    2012-05-01

    Full Text Available Hypertrophic cardiomyopathy (HCM is an autosomal dominant inherited genetic disease characterized by compensatory pathological left ventricle (LV hypertrophy due to sarcomere dysfunction. In an important proportion of patients with HCM, the site and extent of cardiac hypertrophy results in severe obstruction to LV outflow tract (LVOT, contributing to disabling symptoms and increasing the risk of sudden cardiac death (SCD. In patients with progressive and/or refractory symptoms despite optimal pharmacological treatment, invasive therapies that diminish or abolish LVOT obstruction relieve heart failure-related symptoms, improve quality of life and could be associated with long-term survival similar to that observed in the general population. The gold standard in this respect is surgical septal myectomy, which might be supplementary associated with a reduction in SCD. Percutaneous techniques, particularly alcohol septal ablation (ASA and more recently radiofrequency (RF septal ablation, can achieve LVOT gradient reduction and symptomatic benefit in a large proportion of HOCM patients at the cost of a supposedly limited septal myocardial necrosis and a 10-20% risk of chronic atrioventricular block. After an initial period of enthusiasm, standard DDD pacing failed to show in randomized trials significant LVOT gradient reductions and objective improvement in exercise capacity. However, case reports and recent small pilot studies suggested that atrial synchronous LV or biventricular (biV pacing significantly reduce LVOT obstruction and improve symptoms (acutely as well as long-term in a large proportion of severely symptomatic HOCM patients not suitable to other gradient reduction therapies. Moreover, biV/LV pacing in HOCM seems to be associated with significant LV reverse remodelling.

  10. Toward a More Efficient Implementation of Antifibrillation Pacing.

    Directory of Open Access Journals (Sweden)

    Dan Wilson

    Full Text Available We devise a methodology to determine an optimal pattern of inputs to synchronize firing patterns of cardiac cells which only requires the ability to measure action potential durations in individual cells. In numerical bidomain simulations, the resulting synchronizing inputs are shown to terminate spiral waves with a higher probability than comparable inputs that do not synchronize the cells as strongly. These results suggest that designing stimuli which promote synchronization in cardiac tissue could improve the success rate of defibrillation, and point towards novel strategies for optimizing antifibrillation pacing.

  11. Toward a More Efficient Implementation of Antifibrillation Pacing

    Science.gov (United States)

    Wilson, Dan; Moehlis, Jeff

    2016-01-01

    We devise a methodology to determine an optimal pattern of inputs to synchronize firing patterns of cardiac cells which only requires the ability to measure action potential durations in individual cells. In numerical bidomain simulations, the resulting synchronizing inputs are shown to terminate spiral waves with a higher probability than comparable inputs that do not synchronize the cells as strongly. These results suggest that designing stimuli which promote synchronization in cardiac tissue could improve the success rate of defibrillation, and point towards novel strategies for optimizing antifibrillation pacing. PMID:27391010

  12. Managing innovation: lessons from the cardiac-pacing industry.

    Science.gov (United States)

    Gobeli, D H; Rudelius, W

    1985-01-01

    In this article, the authors argue that innovation is a surefire way for a firm to increase its sales and market share. This, in turn, can stimulate American industries and make American firms more competitive in international markets. Through their study of the cardiac-pacing industry, they draw conclusions about what factors contribute to a successful innovation in other industries besides medical electronics. They identify general patterns and stages of the innovation process, key roles top management must fill in an organization, and effective policies that foster important innovations.

  13. Structural analysis of cell wall polysaccharides using PACE

    Energy Technology Data Exchange (ETDEWEB)

    Mortimer, Jennifer C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Joint BioEnergy Institute

    2017-01-01

    The plant cell wall is composed of many complex polysaccharides. The composition and structure of the polysaccharides affect various cell properties including cell shape, cell function and cell adhesion. Many techniques to characterize polysaccharide structure are complicated, requiring expensive equipment and specialized operators e.g. NMR, MALDI-MS. PACE (Polysaccharide Analysis using Carbohydrate gel Electrophoresis) uses a simple, rapid technique to analyze polysaccharide quantity and structure (Goubet et al. 2002). Whilst the method here describes xylan analysis, it can be applied (by use of the appropriate glycosyl hydrolase) to any cell wall polysaccharide.

  14. Setting the right path and pace for integration.

    Science.gov (United States)

    Cwiek, Katherine A; Inniger, Meredith C; Zismer, Daniel K

    2014-04-01

    Far from being a monolithic trend, integration in health care today is progressing in various forms, and at different rates in different markets within and across the range of healthcare organizations. Each organization should develop a tailored strategy that delineates the level and type of integration it will pursue and at what pace to pursue it. This effort will require evaluation of external market conditions with respect to integration and competition and a candid assessment of intraorganizational integration. The compared results of the two analyses will provide the basis for formulating strategy.

  15. Ecuador steps up pace of oil development activity

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This paper reports that oil companies operating in Ecuador plan to quicken the pace of oil development this year. After delays in 1991, companies plan a series of projects to develop reserves discovered the past 3 years estimated at more than 600 million bbl. Oil and Gas Journal estimated Ecuador's proved crude reserves at 1.55 billion bbl as of Jan. 1, 1992. The development push is part of a larger effort needed to ensure Ecuador's status as an oil exporter into the next century. Ecuador is the smallest crude oil producer and exporter in the Organization of Petroleum Exporting Countries

  16. Implant experience with an implantable hemodynamic monitor for the management of symptomatic heart failure.

    Science.gov (United States)

    Steinhaus, David; Reynolds, Dwight W; Gadler, Fredrik; Kay, G Neal; Hess, Mike F; Bennett, Tom

    2005-08-01

    Management of congestive heart failure is a serious public health problem. The use of implantable hemodynamic monitors (IHMs) may assist in this management by providing continuous ambulatory filling pressure status for optimal volume management. The Chronicle system includes an implanted monitor, a pressure sensor lead with passive fixation, an external pressure reference (EPR), and data retrieval and viewing components. The tip of the lead is placed near the right ventricular outflow tract to minimize risk of sensor tissue encapsulation. Implant technique and lead placement is similar to that of a permanent pacemaker. After the system had been successfully implanted in 148 patients, the type and frequency of implant-related adverse events were similar to a single-chamber pacemaker implant. R-wave amplitude was 15.2 +/- 6.7 mV and the pressure waveform signal was acceptable in all but two patients in whom presence of artifacts required lead repositioning. Implant procedure time was not influenced by experience, remaining constant throughout the study. Based on this evaluation, permanent placement of an IHM in symptomatic heart failure patients is technically feasible. Further investigation is warranted to evaluate the use of the continuous hemodynamic data in management of heart failure patients.

  17. The Influence of a Pacesetter on Psychological Responses and Pacing Behavior during a 1600 m Run

    Directory of Open Access Journals (Sweden)

    Christopher L. Fullerton, Andrew M. Lane, Tracey J. Devonport

    2017-12-01

    Full Text Available This study compared the effects of following a pacer versus following a self-paced plan on psychological responses and pacing behavior in well-trained distance runners. Pacing in the present study was individually tailored where each participant developed a personal strategy to ensure their goal time was achieved. We expected that following a pacer would associate with goal achievement, higher pre-run confidence, positive emotions and lower perceived exertion during performance. In a mixed-design repeated-measures study, nineteen well-trained runners completed two 1600m running time trials. Ten runners had a pacer (paced group who supported their individual pacing strategy, and nine participants self-paced running alone (control group. Both groups could check pace using their wrist watch. In contrast to our expectation, results indicated that the paced group reported higher pre-run anxiety with no significant differences in finish time, goal confidence, goal difficulty, perceived exertion, and self-rated performance between groups. We suggest that following a pacer is a skill that requires learning. Following a personalised pacer might associate with higher anxiety due to uncertainty in being able to keep up with the pacer and public visibility of dropping behind, something that is not so observable in a self-paced run completed alone. Future research should investigate mechanisms associated with effective pacing.

  18. Implantable biomedical microsystems design principles and applications

    CERN Document Server

    Bhunia, Swarup; Sawan, Mohamad

    2015-01-01

    Research and innovation in areas such as circuits, microsystems, packaging, biocompatibility, miniaturization, power supplies, remote control, reliability, and lifespan are leading to a rapid increase in the range of devices and corresponding applications in the field of wearable and implantable biomedical microsystems, which are used for monitoring, diagnosing, and controlling the health conditions of the human body. This book provides comprehensive coverage of the fundamental design principles and validation for implantable microsystems, as well as several major application areas. Each co

  19. Lead poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Beijers, J A

    1952-01-01

    Three cases of acute lead poisoning of cattle herds via ingestion are reported, and reference is made to several other incidents of lead in both humans and animals. The quantity of lead which was found in the livers of the dead cows varied from 6.5 to 19 mg/kg, while 1160 mg/kg of lead in the liver was found for a young cow which was poisoned experimentally with 5 gms of lead acetate per day; hence, there appears to be great variability in the amounts deposited that can lead to intoxication and death. No evidence was found for a lead seam around the teeth, prophyrinuria, or basophil granules in the erythrocytes during acute or chronic lead poisoning of cattle or horses examined. Reference is made to attempts of finding the boundary line between increased lead absorption and lead intoxication in humans, and an examination of 60 laborers in an offset-printing office containing a great deal of inhalable lead (0.16 to 1.9 mg/cu m air) is reviewed. Physical deviation, basophylic granulation of erythrocytes, increased lead content of the urine, and porphyrinuria only indicate an increased absorption of lead; the use of the term intoxication is justified if, in addition, there are complaints of lack of appetite, constipation, fatigue, abdominal pain, and emaciation.

  20. The influence of collective behaviour on pacing in endurance competitions

    Directory of Open Access Journals (Sweden)

    Andrew eRenfree

    2015-12-01

    Full Text Available A number of theoretical models have been proposed to explain pacing strategies in individual competitive endurance events. These have typically related to internal regulatory processes informing the making of decisions relating to muscular work rate. Despite a substantial body of research investigating the influence of collective group dynamics on individual behaviours in various animal species, this issue has not been comprehensively studied in individual athletic events. This is surprising given that athletes directly compete in close proximity to one another, and that collective behaviour has also been observed in other human environments. Whilst reasons for adopting collective behaviour are not fully understood, it is thought to result from individual agents following simple local rules resulting in seemingly complex large systems acting to confer some biological advantage to the collective as a whole. Although such collective behaviours may generally be beneficial, endurance events are complicated by the fact that increasing levels of physiological disruption as activity progresses may compromise the ability of individuals to continue to interact with other group members. This could result in early fatigue and relative underperformance due to suboptimal utilisation of physiological resources by some athletes. Alternatively, engagement with a collective behaviour may benefit all due to a reduction in the complexity of decisions to be made and a subsequent reduction in cognitive loading and mental fatigue. This paper seeks evidence for collective behaviour in previously published analyses of pacing behaviour and proposes mechanisms through which it could potentially be either beneficial, or detrimental to individual performance.

  1. Pilot trial of an age-paced parenting newsletter.

    Science.gov (United States)

    Keane, Brigid; Waterston, Tony; McConachie, Helen; Towner, Elizabeth; Cook, Margaret; Birks, Eileen

    2005-10-01

    Supporting parents in the first three years of a child's life has the potential to produce successful outcomes. Present government initiatives such as Sure Start focus on this age group. An American educational intervention, in the style of a monthly newsletter, was adapted for use in the UK for parents of young children. Topics were presented in an easy-to-read format and focused on infant emotional development, parent interaction and play. Newsletters, called Baby Express were posted at monthly intervals to the family home providing age-paced information which could meet the specific needs of parents at that stage of their child's life. The aim of the study was to determine the applicability of the newsletter to UK parents and evaluate their satisfaction. Sixty home-based interviews were conducted and 95 per cent of mothers reported reading all or part of the newsletter. Changes in parenting style were spontaneously reported by 28 per cent of mothers. This study found that an aged-paced parenting newsletter was an acceptable and useful method of supporting parents in the early months of a child's life and promotes positive changes in parenting behaviour.

  2. Social Interaction in Self-paced Distance Education

    Directory of Open Access Journals (Sweden)

    Terry Anderson

    2015-02-01

    Full Text Available In this paper we present a case study of a self-paced university course that was originally designed to support independent, self-paced study at distance. We developed a social media intervention, in design-based research terms, that allows these independent students to contribute archived content to enhance the course, to engage in discussions with other students and to share as little or as much personal information with each other as they wished. We describe the learning design for the intervention and present survey data of student and tutor perception of value and content analysis of the archived contributions. The results indicate that the intervention was positively received by tutors and by the majority (but not all students and that the archive created by the students’ contributions was adding value to the course. We conclude that the intervention was a modest, yet manageable example of a learning enhancement to a traditional cognitive-behavioral, course that has positive impact and potential with little negative impact on workload.

  3. The SolarPACES strategy for the solar thermal breakthrough

    Energy Technology Data Exchange (ETDEWEB)

    Burch, G.D. [U.S. Department of Energy, Washington, DC (United States)

    1997-12-31

    Our national solar thermal research programs and our combined efforts conducted through IEA/SolarPACES have brought about many breakthroughs in the development of solar thermal technology. We have components and systems that are much more efficient, much more reliable, and can be built much more cost-efficiently than just a few years ago. As our technology development proceeds, we undoubtedly will continue to make significant progress, breakthroughs in fact, in all these areas - progress that will bring us even closer to economic parity with more conventional forms of energy. And while this progress is absolutely necessary, the question is whether it will be enough to allow solar thermal to break into the mainstream of global energy supply. Our new IEA/SolarPACES strategy, crafted and approved over the course of the past year, has recognized the changes we must face and given us license to begin to make those changes. We must begin addressing financial hurdles, work to create a more favorable regulatory and tax environment, support development of international partnerships, and expand the visibility and excitement of solar thermal technology to achieve the final breakthroughs we need to allow solar thermal energy to live up to its vast potential. (orig./AKF)

  4. Implant healing in experimental animal models of diabetes.

    Science.gov (United States)

    Le, Nga N; Rose, Michael B; Levinson, Howard; Klitzman, Bruce

    2011-05-01

    Diabetes mellitus is becoming increasingly prevalent worldwide. Additionally, there is an increasing number of patients receiving implantable devices such as glucose sensors and orthopedic implants. Thus, it is likely that the number of diabetic patients receiving these devices will also increase. Even though implantable medical devices are considered biocompatible by the Food and Drug Administration, the adverse tissue healing that occurs adjacent to these foreign objects is a leading cause of their failure. This foreign body response leads to fibrosis, encapsulation of the device, and a reduction or cessation of device performance. A second adverse event is microbial infection of implanted devices, which can lead to persistent local and systemic infections and also exacerbates the fibrotic response. Nearly half of all nosocomial infections are associated with the presence of an indwelling medical device. Events associated with both the foreign body response and implant infection can necessitate device removal and may lead to amputation, which is associated with significant morbidity and cost. Diabetes mellitus is generally indicated as a risk factor for the infection of a variety of implants such as prosthetic joints, pacemakers, implantable cardioverter defibrillators, penile implants, and urinary catheters. Implant infection rates in diabetic patients vary depending upon the implant and the microorganism, however, for example, diabetes was found to be a significant variable associated with a nearly 7.2% infection rate for implantable cardioverter defibrillators by the microorganism Candida albicans. While research has elucidated many of the altered mechanisms of diabetic cutaneous wound healing, the internal healing adjacent to indwelling medical devices in a diabetic model has rarely been studied. Understanding this healing process is crucial to facilitating improved device design. The purpose of this article is to summarize the physiologic factors that

  5. Primary versus secondary intraocular lens implantation in the management of congenital cataract

    Directory of Open Access Journals (Sweden)

    Thanaa H Mohamed

    2016-01-01

    Conclusion Primary IOL implantation was found to be safe and effective in the management of congenital cataract; it leads to lower incidence of complications and better visual outcomes compared with aphakia and secondary IOL implantation.

  6. Lead Toxicity

    Science.gov (United States)

    ... o Do not use glazed ceramics, home remedies, cosmetics, or leaded-crystal glassware unless you know that they are lead safe. o If you live near an industry, mine, or waste site that may have contaminated ...

  7. Relational Leading

    DEFF Research Database (Denmark)

    Larsen, Mette Vinther; Rasmussen, Jørgen Gulddahl

    2015-01-01

    This first chapter presents the exploratory and curious approach to leading as relational processes – an approach that pervades the entire book. We explore leading from a perspective that emphasises the unpredictable challenges and triviality of everyday life, which we consider an interesting......, relevant and realistic way to examine leading. The chapter brings up a number of concepts and contexts as formulated by researchers within the field, and in this way seeks to construct a first understanding of relational leading....

  8. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  9. Intercavitary implants dosage calculation

    International Nuclear Information System (INIS)

    Rehder, B.P.

    The use of spacial geometry peculiar to each treatment for the attainment of intercavitary and intersticial implants dosage calculation is presented. The study is made in patients with intercavitary implants by applying a modified Manchester technique [pt

  10. Pacing a data transfer operation between compute nodes on a parallel computer

    Science.gov (United States)

    Blocksome, Michael A [Rochester, MN

    2011-09-13

    Methods, systems, and products are disclosed for pacing a data transfer between compute nodes on a parallel computer that include: transferring, by an origin compute node, a chunk of an application message to a target compute node; sending, by the origin compute node, a pacing request to a target direct memory access (`DMA`) engine on the target compute node using a remote get DMA operation; determining, by the origin compute node, whether a pacing response to the pacing request has been received from the target DMA engine; and transferring, by the origin compute node, a next chunk of the application message if the pacing response to the pacing request has been received from the target DMA engine.

  11. Lead Test

    Science.gov (United States)

    ... to do renovation and repair projects using lead-safe work practices to avoid creating more lead dust or ... in a dangerous area? Yes. If you are working in a potentially harmful environment with exposure to lead dust or fumes: Wash ...

  12. Comparison of pacing algorithms to avoid unnecessary ventricular pacing in patients with sick sinus node syndrome: a single-centre, observational, parallel study.

    Science.gov (United States)

    Poghosyan, Hermine R; Jamalyan, Smbat V

    2012-10-01

    Reduction of unnecessary ventricular pacing (uVP) is an essential component in the treatment strategy in any pacing population in general. The aim of this study was to evaluate the efficacy of different algorithms to reduce uVP in an adult population with sick sinus syndrome (SSS) treated outside of clinical trials. Evaluation of the relationship between different types of pacing algorithms and clinical outcomes is also provided. This was a single-centre, observational, parallel study, based on retrospective analysis of the Arrhythmology Cardiology Center of Armenia electronic clinical database. This study evaluated atrial pacing percentage (AP%), ventricular pacing percentage (VP%), and the incidence of atrial high rate episodes in 56 patients with SSS using three different pacing strategies: managed VP, search atrioventricular (AV), and fixed long AV. We did not find statistically significant differences in the amount of VP between the groups. Although the atrial high rate percentage (AHR%) tended to be higher in the fixed long AV group, this difference was not statistically significant. Mean VP% and AP% were similar in all three groups. In our study, all three programmed strategies produced the same mean AP% and VP%, and were equally efficient in uVP reduction. There was no relationship between chosen algorithms and the incidence of pacemaker syndrome, hospitalizations, or change in New York Heart Association class. The percentage of AHR was not associated with pacing strategy or co-morbidities but showed borderline correlation with left atrial size.

  13. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  14. The pacing stress test: thallium-201 myocardial imaging after atrial pacing. Diagnostic value in detecting coronary artery disease compared with exercise testing

    International Nuclear Information System (INIS)

    Heller, G.V.; Aroesty, J.M.; Parker, J.A.; McKay, R.G.; Silverman, K.J.; Als, A.V.; Come, P.C.; Kolodny, G.M.; Grossman, W.

    1984-01-01

    Many patients suspected of having coronary artery disease are unable to undergo adequate exercise testing. An alternate stress, pacing tachycardia, has been shown to produce electrocardiographic changes that are as sensitive and specific as those observed during exercise testing. To compare thallium-201 imaging after atrial pacing stress with thallium imaging after exercise stress, 22 patients undergoing cardiac catheterization were studied with both standard exercise thallium imaging and pacing thallium imaging. Positive ischemic electrocardiographic changes (greater than 1 mm ST segment depression) were noted in 11 of 16 patients with coronary artery disease during exercise, and in 15 of the 16 patients during atrial pacing. One of six patients with normal or trivial coronary artery disease had a positive electrocardiogram with each test. Exercise thallium imaging was positive in 13 of 16 patients with coronary artery disease compared with 15 of 16 patients during atrial pacing. Three of six patients without coronary artery disease had a positive scan with exercise testing, and two of these same patients developed a positive scan with atrial pacing. Of those patients with coronary artery disease and an abnormal scan, 85% showed redistribution with exercise testing compared with 87% during atrial pacing. Segment by segment comparison of thallium imaging after either atrial pacing or exercise showed that there was a good correlation of the location and severity of the thallium defects (r . 0.83, p . 0.0001, Spearman rank correlation). It is concluded that the location and presence of both fixed and transient thallium defects after atrial pacing are closely correlated with the findings after exercise testing

  15. Coronary grafts flow and cardiac pacing modalities: how to improve perioperative myocardial perfusion.

    LENUS (Irish Health Repository)

    D'Ancona, Giuseppe

    2012-02-03

    OBJECTIVE: Aim of this study was to investigate modifications of coronary grafts flow during different pacing modalities after CABG. MATERIALS AND METHODS: Two separate prospective studies were conducted in patients undergoing CABG and requiring intraoperative epicardial pacing. In a first study (22 patients) coronary grafts flows were measured during dual chamber pacing (DDD) and during ventricular pacing (VVI). In a second study (10 patients) flows were measured during DDD pacing at different atrio-ventricular (A-V) delay periods. A-V delay was adjusted in 25 ms increments from 25 to 250 ms and flow measurements were performed for each A-V delay increment. A transit time flowmeter was used for the measurements. RESULTS: An average of 3.4 grafts\\/patient were performed. In the first study, average coronary graft flow was 47.4+\\/-20.8 ml\\/min during DDD pacing and 41.8+\\/-18.2 ml\\/min during VVI pacing (P = 0.0004). Furthermore average systolic pressure was 94.3+\\/-10.1 mmHg during DDD pacing and 89.6+\\/-12.2 mmHg during VVV pacing (P = 0.0007). No significant differences in diastolic pressure were recorded during the two different pacing modalities. In the second study, maximal flows were achieved during DDD pacing with an A-V delay of 175 ms (54+\\/-9.6 ml\\/min) and minimal flows were detected at 25 ms A-V delay (38.1+\\/-4.7 ml\\/min) (P=ns). No significant differences in systolic or diastolic blood pressure were noticed during the different A-V delays. CONCLUSION: Grafts flowmetry provides an extra tool to direct supportive measures such as cardiac pacing after CABG. DDD mode with A-V delay around 175 ms. should be preferred to allow for maximal myocardial perfusion via the grafts.

  16. Soft tissue grafting to improve implant esthetics

    Directory of Open Access Journals (Sweden)

    Moawia M Kassab

    2010-09-01

    Full Text Available Moawia M KassabDivision of Periodontics, Marquette University, School of Dentistry, Milwaukee, WI, USAAbstract: Dental implants are becoming the treatment of choice to replace missing teeth, especially if the adjacent teeth are free of restorations. When minimal bone width is present, implant placement becomes a challenge and often resulting in recession and dehiscence around the implant that leads to subsequent gingival recession. To correct such defect, the author turned to soft tissue autografting and allografting to correct a buccal dehiscence around tooth #24 after a malpositioned implant placed by a different surgeon. A 25-year-old woman presented with the chief complaint of gingival recession and exposure of implant threads around tooth #24. The patient received three soft tissue grafting procedures to augment the gingival tissue. The first surgery included a connective tissue graft to increase the width of the keratinized gingival tissue. The second surgery included the use of autografting (connective tissue graft to coronally position the soft tissue and achieve implant coverage. The third and final surgery included the use of allografting material Alloderm to increase and mask the implant from showing through the gingiva. Healing period was uneventful for the patient. After three surgical procedures, it appears that soft tissue grafting has increased the width and height of the gingiva surrounding the implant. The accomplished thickness of gingival tissue appeared to mask the showing of implant threads through the gingival tissue and allowed for achieving the desired esthetic that the patient desired. The aim of the study is to present a clinical case with soft tissue grafting procedures.Keywords: case report, connective tissue, dental implants, allograft, coronally positioned flap

  17. Dopant profile engineering of advanced Si MOSFET's using ion implantation

    International Nuclear Information System (INIS)

    Stolk, P.A.; Ponomarev, Y.V.; Schmitz, J.; Brandenburg, A.C.M.C. van; Roes, R.; Montree, A.H.; Woerlee, P.H.

    1999-01-01

    Ion implantation has been used to realize non-uniform, steep retrograde (SR) dopant profiles in the active channel region of advanced Si MOSFET's. After defining the transistor configuration, SR profiles were formed by dopant implantation through the polycrystalline Si gate and the gate oxide (through-the-gate, TG, implantation). The steep nature of the as-implanted profile was retained by applying rapid thermal annealing for dopant activation and implantation damage removal. For NMOS transistors, TG implantation of B yields improved transistor performance through increased carrier mobility, reduced junction capacitances, and reduced susceptibility to short-channel effects. Electrical measurements show that the gate oxide quality is not deteriorated by the ion-induced damage, demonstrating that transistor reliability is preserved. For PMOS transistors, TG implantation of P or As leads to unacceptable source/drain junction broadening as a result of transient enhanced dopant diffusion during thermal activation

  18. Annealing of ion implanted silicon

    International Nuclear Information System (INIS)

    Chivers, D.; Smith, B.J.; Stephen, J.; Fisher, M.

    1980-09-01

    The newer uses of ion implantation require a higher dose rate. This has led to the introduction of high beam current implanters; the wafers move in front of a stationary beam to give a scanning effect. This can lead to non-uniform heating of the wafer. Variations in the sheet resistance of the layers can be very non-uniform following thermal annealing. Non-uniformity in the effective doping both over a single wafer and from one wafer to another, can affect the usefulness of ion implantation in high dose rate applications. Experiments to determine the extent of non-uniformity in sheet resistance, and to see if it is correlated to the annealing scheme have been carried out. Details of the implantation parameters are given. It was found that best results were obtained when layers were annealed at the maximum possible temperature. For arsenic, phosphorus and antimony layers, improvements were observed up to 1200 0 C and boron up to 950 0 C. Usually, it is best to heat the layer directly to the maximum temperature to produce the most uniform layer; with phosphorus layers however it is better to pre-heat to 1050 0 C. (U.K.)

  19. Neurogenesis in the olfactory bulb induced by paced mating in the female rat is opioid dependent.

    Directory of Open Access Journals (Sweden)

    Marianela Santoyo-Zedillo

    Full Text Available The possibility to control the rate of sexual stimulation that the female rat receives during a mating encounter (pacing increases the number of newborn neurons that reach the granular layer of the accessory olfactory bulb (AOB. If females mate repeatedly, the increase in the number of neurons is observed in other regions of the AOB and in the main olfactory bulb (MOB. It has also been shown that paced mating induces a reward state mediated by opioids. There is also evidence that opioids modulate neurogenesis. In the present study, we evaluated whether the opioid receptor antagonist naloxone (NX could reduce the increase in neurogenesis in the AOB induced by paced mating. Ovariectomized female rats were randomly divided in 5 different groups: 1 Control (not mated treated with saline, 2 control (not mated treated with naloxone, 3 females that mated without controlling the sexual interaction (no-pacing, 4 females injected with saline before pacing the sexual interaction and 5 females injected with NX before a paced mating session. We found, as previously described, that paced mating induced a higher number of new cells in the granular layer of the AOB. The administration of NX before paced mating, blocked the increase in the number of newborn cells and prevented these cells from differentiating into neurons. These data suggest that opioid peptides play a fundamental role in the neurogenesis induced by paced mating in female rats.

  20. Pacing and Self-regulation: Important Skills for Talent Development in Endurance Sports.

    Science.gov (United States)

    Elferink-Gemser, Marije T; Hettinga, Florentina J

    2017-07-01

    Pacing has been characterized as a multifaceted goal-directed process of decision making in which athletes need to decide how and when to invest their energy during the race, a process essential for optimal performance. Both physiological and psychological characteristics associated with adequate pacing and performance are known to develop with age. Consequently, the multifaceted skill of pacing might be under construction throughout adolescence, as well. Therefore, the authors propose that the complex skill of pacing is a potential important performance characteristic for talented youth athletes that needs to be developed throughout adolescence. To explore whether pacing is a marker for talent and how talented athletes develop this skill in middle-distance and endurance sports, they aim to bring together literature on pacing and literature on talent development and self-regulation of learning. Subsequently, by applying the cyclical process of self-regulation to pacing, they propose a practical model for the development of performance in endurance sports in youth athletes. Not only is self-regulation essential throughout the process of reaching the long-term goal of athletic excellence, but it also seems crucial for the development of pacing skills within a race and the development of a refined performance template based on previous experiences. Coaches and trainers are advised to incorporate pacing as a performance characteristic in their talent-development programs by stimulating their athletes to reflect, plan, monitor, and evaluate their races on a regular basis to build performance templates and, as such, improve their performance.

  1. Aspectos técnicos da cateterização do seio coronariano baseada no componente atrial do eletrograma intracavitário e anatomia radiológica durante o procedimento de implante de marcapasso biventricular Technical aspects of coronary sinus catheterization based on the atrial component of the intracavitary electrogram and radiological anatomy during the implantation procedure of a biventricular pacemaker

    Directory of Open Access Journals (Sweden)

    Fernando Sérgio Oliva de Souza

    2006-04-01

    Full Text Available OBJETIVO: Apresentar uma proposição técnica baseada na experiência de 130 implantes utilizando técnica simplificada para cateterização do seio coronariano, baseada no componente atrial do eletrograma intracavi-tário e anatomia radiológica. MÉTODOS: De outubro de 2001 a outubro de 2004 foram realiza-dos 130 implantes de marcapasso biventricular, utilizando-se anatomia radiológica e observação de eletrograma intracavitário, com prioridade ao componente atrial. RESULTADOS: O implante do sistema, utilizando-se a estimulação do ventrículo esquerdo via seio coronariano, não foi possível em 8 pacientes. Em 12 pacientes foram observadas dificuldades na canulação do óstio coronário e em 15 pacientes observaram-se dificuldades de progressão do eletrodo através do seio coronariano. O tempo médio de utilização de radioscopia foi de 18,69 min. CONCLUSÃO: A técnica de implante, utilizando a morfologia do componente atrial do eletrograma intracavitário e anatomia radiológica, demonstrou ser pouco trabalhosa, segura e eficaz para canulação do óstio do seio coronariano, necessitando de reduzido tempo de radioscopia.OBJECTIVE: To present a technical proposal based on the experience of 130 implantations using a simplified technique for coronary sinus catheterization, based on the atrial component of the intracavitary electrogram and radiological anatomy. METHODS: From October, 2001 to October, 2004, 130 biventricular pacemaker implantations were performed, using radiological anatomy and observation of the intracavitary electrogram, focusing on the atrial component. RESULTS: The implantation of the system using left ventricular pacing via coronary sinus was not possible in 8 patients. Difficulties on the cannulation of the coronary ostium were felt in 12 patients and difficulties of lead advancement through the coronary sinus were felt in 15 patients. The mean time of radioscopy utilization was 18.69 min. CONCLUSION: The

  2. Effect of dual-chamber minimal ventricular pacing on paroxysmal atrial fibrillation incidence in myotonic dystrophy type 1 patients: A prospective, randomized, single-blind, crossover study.

    Science.gov (United States)

    Russo, Vincenzo; Papa, Andrea Antonio; Rago, Anna; Ciardiello, Carmine; Nigro, Gerardo

    2018-03-08

    Atrial fibrillation (AF) is a common finding in the myotonic dystrophy type 1 (DM1) population. Pacemakers (PMs) may facilitate the diagnosis and management of frequent subclinical asymptomatic AF episodes. The purpose of this study was to evaluate the effect of minimal ventricular pacing on paroxysmal AF incidence in DM1 patients during a 24-month follow-up period. We enrolled 70 DM1 patients (age 43.4 ± 13.8 years; 39 women) who underwent dual-chamber PM implantation. Patients were randomized to minimizing ventricular pacing features (ON) or not (OFF). Patients crossed over to the opposite pacing programming 12 months later. We counted the number of DM1 patients with at least 1 episode of AF, the AF total duration, and the burden recorded by PM diagnostics during the MVP ON and OFF phases. Twenty-five DM1 patients (41.7%) showed at least 1 AF episode. Seven patients (11.7%) demonstrated AF episodes during MVP ON phase and 25 patients (41.7%) during MVP OFF phase (P MVP ON or OFF phase, 3 patients had AF episodes only during MVP ON phase, 21 patients had AF episodes only during MVP OFF phase, and 4 patients had AF episodes during MVP ON and OFF phases. Activation of the MVP algorithm was associated with a 44% reduction in relative risk of developing AF. Furthermore, during the MVP ON phases, the study population showed a shorter total AF duration and a lower AF burden. MVP is an efficacy strategy for reducing the risk of AF in DM1 patients who have undergone PM implantation. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  3. Diastolic And Systolic Right Ventricular Dysfunction Precedes Left Ventricular Dysfunction In Patients Paced From Right Ventricular Apex

    Directory of Open Access Journals (Sweden)

    Dwivedi SK

    2006-07-01

    Full Text Available Background: Cardiac dysfunction after right ventricular (RV apical pacing is well known but its extent, time frame of appearance and individual effect on left ventricular (LV, RV systolic and diastolic parameters has not evaluated in a systematic fashion. Methods: Patients with symptomatic bradycardia and ACC-AHA Class I indication for permanent pacemaker implantation (PPI were implanted a single chamber (VVI pacemaker. They were followed prospectively by echocardiographic examination which was done at baseline, 1 week, 1 month and 6 months after implantation. Parameters observed were chamber dimensions (M-line, chamber volumes, cardiac output (modified Simpson's method, systolic functions (ejection fraction, pre-ejection period, ejection time and ratio and diastolic functions( isovolumic relaxation time & deceleration time of left and right heart. Results: Forty eight consecutive patients (mean age 65.6±11.8 yrs, 66.7% males, mean EF 61.82±10.36% implanted a VVI pacemaker were enrolled in this study. The first significant change to appear in cardiac function after VVI pacing was in diastolic properties of RV as shown by increase in RV isovolumic relaxation time (IVRT from 65.89±15.93 to 76.58±17.00 ms,(p<0.001 at 1week and RV deceleration time (DT from 133.84±38.13 to 153.09±31.41 ms, (p=0.02 at 1 month. Increase in RV internal dimension (RVID from 1.26±0.41 to 1.44±0.44, (p<0.05 was also noticed at 1 week. The LV diastolic parameters were significantly altered after 1 month with increase in LV-IVRT from 92.36±21.47 to 117.24±27.21ms, (p<0.001 and increase in LV DT from 147.56±31.84 to 189.27±28.49ms,(p<0.01. This was followed by LV systolic abnormality which appeared at 6 months with an increase in LVPEP from 100.33±14.43 to 118.41±21.34ms, (p<0.001 and increase in LVPEP/LVET ratio from 0.34±0.46 to 0.44±0.10, (p<0.001]. The reduction in LV EF was manifested at 6 months falling from 61.82±10.36% to52.52±12.11%, (p<0

  4. Increases in myocardial workload induced by rapid atrial pacing trigger alterations in global metabolism.

    Directory of Open Access Journals (Sweden)

    Aslan T Turer

    Full Text Available To determine whether increases in cardiac work lead to alterations in the plasma metabolome and whether such changes arise from the heart or peripheral organs.There is growing evidence that the heart influences systemic metabolism through endocrine effects and affecting pathways involved in energy homeostasis.Nineteen patients referred for cardiac catheterization were enrolled. Peripheral and selective coronary sinus (CS blood sampling was performed at serial timepoints following the initiation of pacing, and metabolite profiling was performed by liquid chromatography-mass spectrometry (LC-MS.Pacing-stress resulted in a 225% increase in the median rate·pressure product from baseline. Increased myocardial work induced significant changes in the peripheral concentration of 43 of 125 metabolites assayed, including large changes in purine [adenosine (+99%, p = 0.006, ADP (+42%, p = 0.01, AMP (+79%, p = 0.004, GDP (+69%, p = 0.003, GMP (+58%, p = 0.01, IMP (+50%, p = 0.03, xanthine (+61%, p = 0.0006], and several bile acid metabolites. The CS changes in metabolites qualitatively mirrored those in the peripheral blood in both timing and magnitude, suggesting the heart was not the major source of the metabolite release.Isolated increases in myocardial work can induce changes in the plasma metabolome, but these changes do not appear to be directly cardiac in origin. A number of these dynamic metabolites have known signaling functions. Our study provides additional evidence to a growing body of literature on metabolic 'cross-talk' between the heart and other organs.

  5. Automatic user customization for improving the performance of a self-paced brain interface system.

    Science.gov (United States)

    Fatourechi, Mehrdad; Bashashati, Ali; Birch, Gary E; Ward, Rabab K

    2006-12-01

    Customizing the parameter values of brain interface (BI) systems by a human expert has the advantage of being fast and computationally efficient. However, as the number of users and EEG channels grows, this process becomes increasingly time consuming and exhausting. Manual customization also introduces inaccuracies in the estimation of the parameter values. In this paper, the performance of a self-paced BI system whose design parameter values were automatically user customized using a genetic algorithm (GA) is studied. The GA automatically estimates the shapes of movement-related potentials (MRPs), whose features are then extracted to drive the BI. Offline analysis of the data of eight subjects revealed that automatic user customization improved the true positive (TP) rate of the system by an average of 6.68% over that whose customization was carried out by a human expert, i.e., by visually inspecting the MRP templates. On average, the best improvement in the TP rate (an average of 9.82%) was achieved for four individuals with spinal cord injury. In this case, the visual estimation of the parameter values of the MRP templates was very difficult because of the highly noisy nature of the EEG signals. For four able-bodied subjects, for which the MRP templates were less noisy, the automatic user customization led to an average improvement of 3.58% in the TP rate. The results also show that the inter-subject variability of the TP rate is also reduced compared to the case when user customization is carried out by a human expert. These findings provide some primary evidence that automatic user customization leads to beneficial results in the design of a self-paced BI for individuals with spinal cord injury.

  6. Pacing Behavior and Tactical Positioning in 1500-m Short-Track Speed Skating.

    Science.gov (United States)

    Konings, Marco J; Noorbergen, Olaf S; Parry, David; Hettinga, Florentina J

    2016-01-01

    To gain more insight in pacing behavior and tactical positioning in 1500-m short-track speed skating, a sport in which several athletes directly compete in the same race. Lap times and intermediate rankings of elite 1500-m short-track- skating competitors were collected over the season 2012-13 (N = 510, 85 races). Two statistical approaches were used to assess pacing behavior and tactical positioning. First, lap times were analyzed using a MANOVA, and for each lap differences between sex, race type, final rankings, and stage of competition were determined. Second, Kendall tau b correlations were used to assess relationships between intermediate and final rankings. In addition, intermediate rankings of the winner of each race were examined. In 1500 m (13.5 laps of 111.12 m), correlations between intermediate and final ranking gradually increased throughout the race (eg, lap 1, r = .05; lap 7, r = .26; lap 13, r = .85). Moreover, the percentage of race winners skating in the leading position was over 50% during the last 3 laps. Top finishers were faster than bottom-place finishers only during the last 5 laps, with on average 0.1- to 1.5-s faster lap times of the race winners compared with the others during the last 5 laps. Although a fast start led to faster finishing times, top finishers were faster than bottom-placed finishers only during the last 5 laps. Moreover, tactical positioning at 1 of the foremost positions during the latter phase of the race appeared to be a strong determinant of finishing position.

  7. Mecanobiología de la interfase hueso-implante dental Mechanobiology of bone-dental implant interphase

    Directory of Open Access Journals (Sweden)

    Juan Carlos Vanegas Acosta

    2010-03-01

    Full Text Available La osteointegración es la conexión estructural y funcional entre el hueso y un implante. Cuando un implante se inserta en el hueso, se crea la denominada interfase hueso-implante, una zona de unión entre la superficie del biomaterial del implante y el hueso circundante. La cicatrización de esta interfase depende de las condiciones biológicas del hueso, las características de diseño del implante y la distribución de cargas entre hueso e implante. En este artículo se hace una revisión del proceso de cicatrización de la interfase hueso-implante para el caso de un implante dental. El objetivo es describir la secuencia de eventos biológicos iniciados con la lesión causada por la inserción del implante y que concluyen con la formación de nuevo hueso en la interfase. Esta descripción incluye una novedosa clasificación de los fenómenos mecánicos que intervienen durante el proceso de cicatrización de los tejidos lesionados. Esta descripción mecanobiológica de la interfase hueso-implante dental se utiliza para determinar las características más relevantes a tener en cuenta en la formulación de un modelo matemático de la osteointegración de implantes dentales.The osteointegration is the structural and functional connection between bone and implant. When an implant is inserted in bone, it creates the so-called bone-implant interphase, a joint zone between implant biomaterial surface and the surrounding bone. The healing of this interphase depends on bone biological conditions, characteristic of implant design and the distribution of loads between bone and implant. The aim of present article is to review of healing process of bone-implant interphase for a dental implant and also to describe the sequence of biological events beginning with lesion caused by implant insertion and leading to the formation of a new bone in the interphase. This description includes a novel classification of mechanical phenomena present in the healing

  8. Group D. Initiator paper. Implants--peri-implant (hard and soft tissue) interactions in health and disease: the impact of explosion of implant manufacturers.

    Science.gov (United States)

    Ivanovski, Saso

    2015-01-01

    1. The best-documented implants have a threaded solid screw-type design and are manufactured from commercially pure (grade IV) titanium. There is good evidence to support implants ≥ 6 mm in length, and ≥ 3 mm in diameter. 2. Integrity of the seal between the abutment and the implant is important for several reasons, including minimization of mechanical and biological complications and maintaining marginal bone levels. Although the ideal design features of the implant-abutment connection have not been determined, an internal connection, micro-grooves at the implant collar, and horizontal offset of the implant-abutment junction (platform switch) appear to impart favorable properties. 3. Implants with moderately rough implant surfaces provide advantages over machined surfaces in terms of the speed and extent of osseointegration. While the favorable performances of both minimally and moderately rough surfaces are supported by long-term data, moderately rough surfaces provide superior outcomes in compromised sites, such as the posterior maxilla. 4. Although plaque is critical in the progression of peri-implantitis, the disease has a multi-factorial aetiology, and may be influenced by poor integrity of the abutment/implant connection. Iatrogenic factors, such as the introduction of a foreign body. (e.g., cement) below the mucosal margin, can be important contributors. 5. Clinicians should exercise caution when using a particular implant system, ensuring that the implant design is appropriate and supported by scientific evidence. Central to this is access to and participation in quality education on the impact that implant characteristics can have on clinical outcomes. Caution should be exercised in utilizing non-genuine restorative componentry that may lead to a poor implant-abutment fit and subsequent technical and biological complications.

  9. Diagnosis and therapy of atrial tachyarrhythmias in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-11-01

    Devices capable of monitoring and treating atrial tachyarrhythmias provide information about the natural history of the arrhythmias and potentially can influence their natural course by electrical therapy early after onset. Types of atrial arrhythmias and efficacy of device therapies were evaluated in 30 patients implanted with the Medtronic model 7250 Jewel AF implantable cardioverter defibrillator (ICD). All patients had structural heart disease and documented sustained ventricular and atrial arrhythmias (27 with atrial fibrillation [AF]) before implant. Twenty patients were taking amiodarone, and three were taking sotalol. During 20+/-10 months of follow-up, 600 atrial arrhythmia recurrences were documented in 50% of patients. AF was diagnosed in 19%, fast polymorphic atrial tachycardia (AT) in 20%, fast monomorphic AT in 57%, and slow AT in 4% of episodes. The two adaptive pacing therapies, burst and ramp, together with the 50-Hz burst, were successful in 57% of detected atrial arrhythmias. Burst and ramp were responsible for 49% and 50-Hz burst for 51% of successfully treated arrhythmias; 33% of the episodes terminated spontaneously. No ventricular proarrhythmia was observed due to atrial pacing therapies. In 30% of episodes, dual chamber pacing was required due to post termination bradycardia. Atrial arrhythmia recurrences in patients with dilated cardiomyopathy were not amenable to pacing therapies. Several aspects of atrial arrhythmia diagnosis, therapy, and documentation that are specific for functioning of the Jewel AF are discussed. Atrial arrhythmias in ICD patients with diseased hearts who are taking Class III antiarrhythmics frequently had longer cycle lengths than AF. Half of these arrhythmias could be terminated with pacing therapies; one third terminated spontaneously.

  10. The Pace and Shape of Senescence in Angiosperms

    DEFF Research Database (Denmark)

    Baudisch, Annette; Salguero-Gómez, Roberto; Jones, Owen

    2013-01-01

    1. Demographic senescence, the decay in fertility and increase in the risk of mortality with age, is one of the most striking phenomena in ecology and evolution. Comparative studies of senescence patterns of plants are scarce, and consequently, little is known about senescence and its determinants...... (‘senescence’), decreases (‘negative senescence’) or remains constant over age (‘negligible senescence’). 3. We extract mortality trajectories from ComPADRe III, a data base that contains demographic information for several hundred plant species. We apply age-from-stage matrix decomposition methods to obtain...... age-specific trajectories from 290 angiosperm species of various growth forms distributed globally. From these trajectories, we survey pace and shape values and investigate how growth form and ecoregion influence these two aspects of mortality using a Bayesian regression analysis that accounts...

  11. Quick pace of property acquisitions requires two-stage evaluations

    International Nuclear Information System (INIS)

    Hollo, R.; Lockwood, S.

    1994-01-01

    The traditional method of evaluating oil and gas reserves may be too cumbersome for the quick pace of oil and gas property acquisition. An acquisition evaluator must decide quickly if a property meets basic purchase criteria. The current business climate requires a two-stage approach. First, the evaluator makes a quick assessment of the property and submits a bid. If the bid is accepted then the evaluator goes on with a detailed analysis, which represents the second stage. Acquisition of producing properties has become an important activity for many independent oil and gas producers, who must be able to evaluate reserves quickly enough to make effective business decisions yet accurately enough to avoid costly mistakes. Independent thus must be familiar with how transactions usually progress as well as with the basic methods of property evaluation. The paper discusses acquisition activity, the initial offer, the final offer, property evaluation, and fair market value

  12. The pace of shifting climate in marine and terrestrial ecosystems

    DEFF Research Database (Denmark)

    Burrows, Michael T.; Schoeman, David S.; Buckley, Lauren B.

    2011-01-01

    Climate change challenges organisms to adapt or move to track changes in environments in space and time. We used two measures of thermal shifts from analyses of global temperatures over the past 50 years to describe the pace of climate change that species should track: the velocity of climate...... change (geographic shifts of isotherms over time) and the shift in seasonal timing of temperatures. Both measures are higher in the ocean than on land at some latitudes, despite slower ocean warming. These indices give a complex mosaic of predicted range shifts and phenology changes that deviate from...... simple poleward migration and earlier springs or later falls. They also emphasize potential conservation concerns, because areas of high marine biodiversity often have greater velocities of climate change and seasonal shifts....

  13. The heart and cardiac pacing in Steinert disease.

    Science.gov (United States)

    Nigro, Gerardo; Papa, Andrea Antonio; Politano, Luisa

    2012-10-01

    Myotonic dystrophy (Dystrophia Myotonica, DM) is the most frequently inherited neuromuscular disease of adult life. It is a multisystemic disease with major cardiac involvement. Core features of myotonic dystrophy are myotonia, muscle weakness, cataract, respiratory failure and cardiac conduction abnormalities. Classical DM, first described by Steinert and called Steinert's disease or DM1 (Dystrophia Myotonica type 1) has been identified as an autosomal dominant disorder associated with the presence of an abnormal expansion of a CTG trinucleotide repeat in the 3' untranslated region of DMPK gene on chromosome 19. This review will mainly focus on the various aspects of cardiac involvement in DM1 patients and the current role of cardiac pacing in their treatment.

  14. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  15. Influence of internal current and pacing current on pacemaker longevity.

    Science.gov (United States)

    Schuchert, A; Kuck, K H

    1994-01-01

    The effects of lower pulse amplitude on battery current and pacemaker longevity were studied comparing the new, small-sized VVI pacemaker, Minix 8341, with the former model, Pasys 8329. Battery current was telemetrically measured at 0.8, 1.6, 2.5, and 5.0 V pulse amplitude and 0.05, 0.25, 0.5, and 1.0 msec pulse duration. Internal current was assumed to be equal to the battery current at 0.8 V and 0.05 msec. Pacing current was calculated subtracting internal current from battery current. The Minix pacemaker had a significantly lower battery current because of a lower internal current (Minix: 4.1 +/- 0.1 microA; Pasys: 16.1 +/- 0.1 microA); pacing current of both units was similar. At 0.5 msec pulse duration, the programming from 5.0-2.5 V pulse amplitude resulted in a greater relative reduction of battery current in the newer pacemaker (51% vs 25%). Projected longevity of each pacemaker was 7.9 years at 5.0 V and 0.5 msec. The programming from 5.0-2.5 V extended the projected longevity by 2.3 years (Pasys) and by 7.1 years (Minix). The longevity was negligibly longer after programming to 1.6 V. extension of pacemaker longevity can be achieved with the programming to 2.5 V or less if the connected pacemakers need a low internal current for their circuitry.

  16. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... and Medical Procedures Implants and Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin ... the Use of Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ...

  17. Pacemaker lead erosion simulating "Loch Ness Monster": conservative management.

    Science.gov (United States)

    Garg, Naveen; Moorthy, Nagaraja

    2012-12-01

    The majority of pacemaker pocket or lead erosions are due to either mechanical erosion by the bulky pulse generator or secondary to pacemaker pocket infection. We describe an unusual case of delayed pacemaker lead erosion causing extrusion of a portion of the pacing lead, with separate entry and exit points, with the gap filled with new skin formation, simulating the "Loch Ness Monster", which was successfully managed conservatively by surgical reinsertion.

  18. Leading Democratically

    Science.gov (United States)

    Brookfield, Stephen

    2010-01-01

    Democracy is the most venerated of American ideas, the one for which wars are fought and people die. So most people would probably agree that leaders should be able to lead well in a democratic society. Yet, genuinely democratic leadership is a relative rarity. Leading democratically means viewing leadership as a function or process, rather than…

  19. The medically compromised patient: Are dental implants a feasible option?

    Science.gov (United States)

    Vissink, A; Spijkervet, Fkl; Raghoebar, G M

    2018-03-01

    In healthy subjects, dental implants have evolved to be a common therapy to solve problems related to stability and retention of dentures as well as to replace failing teeth. Although dental implants are applied in medically compromised patients, it is often not well known whether this therapy is also feasible in these patients, whether the risk of implant failure and developing peri-implantitis is increased, and what specific preventive measures, if any, have to be taken when applying dental implants in these patients. Generally speaking, as was the conclusion by the leading review of Diz, Scully, and Sanz on placement of dental implants in medically compromised patients (J Dent, 41, 2013, 195), in a few disorders implant survival may be lower, and the risk of a compromised peri-implant health and its related complications be greater, but the degree of systemic disease control outweighs the nature of the disorder rather than the risk accompanying dental implant treatment. So, as dental implant treatment is accompanied by significant functional benefits and improved oral health-related quality of life, dental implant therapy is a feasible treatment in almost any medically compromised patient when the required preventive measures are taken and follow-up care is at a high level. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.

  20. Evaluation of contiguous implants with cement-retained implant-abutment connections. A minipig study

    Directory of Open Access Journals (Sweden)

    Raquel Rezende Martins de Barros

    2014-03-01

    Full Text Available Aim: The presence of a microgap at the implant-abutment interface may permit bacterial contamination and lead to bone resorption, interfering with papillae formation. The present study evaluated adjacent implants with cement-retained abutments as an option to control such deleterious effects. Materials and methods Seven minipigs had their bilateral mandibular premolars previously extracted. After 8 weeks, four implants were installed in each hemi-mandible of each animal. The adjacent implants were randomly inserted on one side at the crestal bone level and on the other, 1.5 mm subcrestally. Immediately, a non-submerged healing and functional loading were provided with the abutments cementation and prostheses installation. Clinical examination and histomorphometry served to analyze the implant success. Results A total of 52 implants were evaluated at the end of the study. The subcrestal group achieved statistical better results when compared to the crestal group, clinically in papillae formation (1.97 x 1.57 mm and histomorphometrically in crestal bone remodeling (1.17 x 1.63 mm, bone density (52.39 x 45.22% and bone-implant contact (54.13 x 42.46%. Conclusion The subcrestal placement of cement-retained abutment implants showed better indexes of osseointegration and also improved papillae formation and crestal bone remodeling at the interimplant area after immediate loading, making them a promising option for the treatment of esthetic regions.

  1. Usher syndrome and cochlear implantation.

    Science.gov (United States)

    Loundon, Natalie; Marlin, Sandrine; Busquet, Denise; Denoyelle, Françoise; Roger, Gilles; Renaud, Francis; Garabedian, Erea Noel

    2003-03-01

    To evaluate the symptoms leading to diagnosis and the quality of rehabilitation after cochlear implantation in Usher syndrome. Retrospective cohort study. ENT department of a tertiary referral hospital. Among 210 patients given an implantation in the Ear, Nose, and Throat department, 185 were congenitally deaf and 13 had Usher syndrome (7.0%). Five had a family history of Usher, and eight were sporadic cases. Eleven cases were Usher type I, one was Usher type III, and one was not classified. The age at implantation ranged from 18 months to 44 years (mean, 6 years 1 month). The mean follow-up was 52 months (range, 9 months to 9 years). All patients had audiophonological and clinical examination, computed tomography scan of the temporal bones, ophthalmologic examination with fundoscopy, and an electroretinogram. Cerebral magnetic resonance imaging and vestibular examination were performed in 9 of 13 and 10 of 13 cases, respectively. Logopedic outcome measured preimplant and postimplant closed- and open-set word recognition and oral expression at follow-up. The most frequent initial sign of Usher syndrome was delayed walking, with a mean age of 20 months. Among the 172 other congenitally deaf children with implants, when deafness was not associated with other neurologic disorders, the mean age at walking was 14 months (p < 0.001). The fundoscopy was always abnormal after the age of 5 years, and the electroretinogram was abnormal in all cases. Vestibular function was abnormal in all but one case (nonclassified). The computed tomography scan and the magnetic resonance imaging were always normal. Logopedic results with cochlear implants showed good perception skills in all but one case. The best perceptive results were obtained in children implanted before the age of 9 years. Oral language had significantly progressed in 9 of 13 at follow-up. There was no relation between the visual acuity and the logopedic results. The earliest clinical sign associated with deafness

  2. How Pacing of Multimedia Instructions Can Influence Modality Effects: A Case of Superiority of Visual Texts

    Science.gov (United States)

    Stiller, Klaus D.; Freitag, Annika; Zinnbauer, Peter; Freitag, Christian

    2009-01-01

    "Present text accompanying pictures aurally to promote learning" is a well established principle of instructional design. But recently, it was shown that under certain conditions visual texts can be preferable. Instructional pacing seems to be one of these conditions that mediate effects. Especially, enabling learners to pace an…

  3. Racing an Opponent Alters Pacing, Performance and Muscle Force Decline, But Not RPE

    NARCIS (Netherlands)

    Konings, Marco J; Parkinson, Jordan; Zijdewind, Inge; Hettinga, Florentina

    PURPOSE: Performing against a virtual opponent has been shown to invite a change in pacing and improve time trial (TT) performance. This study explored how this performance improvement is established by assessing changes in pacing, neuromuscular function and perceived exertion. METHODS: After a peak

  4. Differential effects of film on preschool children's behaviour dependent on editing pace.

    Science.gov (United States)

    Kostyrka-Allchorne, Katarzyna; Cooper, Nicholas R; Gossmann, Anna Maria; Barber, Katy J; Simpson, Andrew

    2017-05-01

    Evidence on how the pace of television and film editing affects children's behaviour and attention is inconclusive. We examined whether a fast-paced film affected how preschool-aged children interacted with toys. The study comprised 70 children (36 girls) aged two to four-and-a-half years who attended preschools in Essex, United Kingdom. The children were paired up and tested with either a fast- or a slow-paced film of a narrator reading a children's story. The fast-paced version had 102 camera cuts and 16 still images, and the slow-paced version had 22 camera cuts and four still images. Each dyad took part in two video-recorded free-play sessions, before and after they watched one of the specially edited four-minute films. The number of toys the children played with before and after the film sessions was recorded. Before they watched the films, the children's behaviour did not differ between the groups. However, after watching the film, the children in the fast-paced group shifted their attention between toys more frequently than the children who watched the slow-paced film. Even a brief exposure to differently paced films had an immediate effect on how the children interacted with their toys. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  5. Levodopa reinstates connectivity from prefrontal to premotor cortex during externally paced movement in Parkinson's disease

    DEFF Research Database (Denmark)

    Herz, Damian M; Siebner, Hartwig R; Hulme, Oliver J

    2014-01-01

    , which were externally paced at a rate of 0.5Hz. This required participants to align their movement velocity to the slow external pace. Patients were studied after at least 12-hour withdrawal of dopaminergic medication (OFF state) and after intake of the dopamine precursor levodopa (ON state) in order...

  6. Child and Parental Outcomes Following Involvement in a Preventive Intervention: Efficacy of the PACE Program

    Science.gov (United States)

    Begle, Angela Moreland; Dumas, Jean E.

    2011-01-01

    This study evaluated whether engagement (i.e., attendance and quality of participation) in the Parenting our Children to Excellence (PACE) program predicted positive child and parent outcomes. PACE in an 8-week preventive intervention aimed at parents of preschool children. The study investigated the relation of engagement to outcomes in an…

  7. Challenge of Engaging All Students via Self-Paced Interactive Electronic Learning Tutorials for Introductory Physics

    Science.gov (United States)

    DeVore, Seth; Marshman, Emily; Singh, Chandralekha

    2017-01-01

    As research-based, self-paced electronic learning tools become increasingly available, a critical issue educators encounter is implementing strategies to ensure that all students engage with them as intended. Here, we first discuss the effectiveness of electronic learning tutorials as self-paced learning tools in large enrollment brick and mortar…

  8. Financing the Business. PACE Revised. Level 1. Unit 8. Research & Development Series No. 240AB8.

    Science.gov (United States)

    Ashmore, M. Catherine; Pritz, Sandra G.

    This lesson on financing a business, the eighth in a series of 18 units, is part of the first level of a comprehensive entrepreneurship curriculum entitled: A Program for Acquiring Competence in Entrepreneurship (PACE). (Designed for use with secondary students, the first level of PACE introduces students to the concepts involved in…

  9. Keeping Pace with K-12 Online & Blended Learning: An Annual Review of Policy and Practice, 2013

    Science.gov (United States)

    Watson, John; Murin, Amy; Vashaw, Lauren; Gemin, Butch; Rapp, Chris

    2013-01-01

    This is the 10th annual "Keeping Pace" report. "Keeping Pace" has several goals: (1) add to the body of knowledge about online education policy and practice, and make recommendations for advances; (2) serve as a reference source for information about programs and policies across the country, both for policymakers and…

  10. The corticospinal responses of metronome-paced, but not self-paced strength training are similar to motor skill training.

    Science.gov (United States)

    Leung, Michael; Rantalainen, Timo; Teo, Wei-Peng; Kidgell, Dawson

    2017-12-01

    The corticospinal responses to skill training may be different to strength training, depending on how the strength training is performed. It was hypothesised that the corticospinal responses would not be different following skill training and metronome-paced strength training (MPST), but would differ when compared with self-paced strength training (SPST). Corticospinal excitability, short-interval intra-cortical inhibition (SICI) and strength and tracking error were measured at baseline and 2 and 4 weeks. Participants (n = 44) were randomly allocated to visuomotor tracking, MPST, SPST or a control group. MPST increased strength by 7 and 18%, whilst SPST increased strength by 12 and 26% following 2 and 4 weeks of strength training. There were no changes in strength following skill training. Skill training reduced tracking error by 47 and 58% at 2 and 4 weeks. There were no changes in tracking error following SPST; however, tracking error reduced by 24% following 4 weeks of MPST. Corticospinal excitability increased by 40% following MPST and by 29% following skill training. There was no change in corticospinal excitability following 4 weeks of SPST. Importantly, the magnitude of change between skill training and MPST was not different. SICI decreased by 41 and 61% following 2 and 4 weeks of MPST, whilst SICI decreased by 41 and 33% following 2 and 4 weeks of skill training. Again, SPST had no effect on SICI at 2 and 4 weeks. There was no difference in the magnitude of SICI reduction between skill training and MPST. This study adds new knowledge regarding the corticospinal responses to skill and MPST, showing they are similar but different when compared with SPST.

  11. Amorphous clusters in Co implanted ZnO induced by boron pre-implantation

    Energy Technology Data Exchange (ETDEWEB)

    Potzger, K.; Shalimov, A.; Zhou, S.; Schmidt, H.; Mucklich, A.; Helm, M.; Fassbender, J.; Liberati, M.; Arenholz, E.

    2009-02-09

    We demonstrate the formation of superparamagnetic/ferromagnetic regions within ZnO(0001) single crystals sequently implanted with B and Co. While the pre-implantation with B plays a minor role for the electrical transport properties, its presence leads to the formation of amorphous phases. Moreover, B acts strongly reducing on the implanted Co. Thus, the origin of the ferromagnetic ordering in local clusters with large Co concentration is itinerant d-electrons as in the case of metallic Co. The metallic amorphous phases are non-detectable by common X-ray diffraction.

  12. Mechanisms underlying syntactic comprehension deficits in vascular aphasia: new evidence from self-paced listening.

    Science.gov (United States)

    Caplan, David; Michaud, Jennifer; Hufford, Rebecca

    2015-01-01

    Sixty-one people with aphasia (pwa) and 41 matched controls were tested for the ability to understand sentences that required the ability to process particular syntactic elements and assign particular syntactic structures. Participants paced themselves word-by-word through 20 examples of 11 spoken sentence types and indicated which of two pictures corresponded to the meaning of each sentence. Sentences were developed in pairs such that comprehension of the experimental version of a pair required an aspect of syntactic processing not required in the corresponding baseline sentence. The need for the syntactic operations required only in the experimental version was triggered at a "critical word" in the experimental sentence. Listening times for critical words in experimental sentences were compared to those for corresponding words in the corresponding baseline sentences. The results were consistent with several models of syntactic comprehension deficits in pwa: resource reduction, slowed lexical and/or syntactic processing, abnormal susceptibility to interference from thematic roles generated non-syntactically. They suggest that a previously unidentified disturbance limiting the duration of parsing and interpretation may lead to these deficits, and that this mechanism may lead to structure-specific deficits in pwa. The results thus point to more than one mechanism underlying syntactic comprehension disorders both across and within pwa.

  13. METODE FUTURE PACING HYPNOTHERAPY UNTUK MENURUNKAN TINGKAT KECEMASAN PADA MAHASISWA BARU

    Directory of Open Access Journals (Sweden)

    Zahro Varisna Rohmadani

    2017-09-01

    Full Text Available Penelitian ini bertujuan untuk mengetahui efektivitas metode future pacing hypnotherapy dalam menurunkan tingkat kecemasan pada mahasiswa baru. Subjek penelitian adalah 20 mahasiswa/i baru, 10 mahasiswa di kelompok eksperimen dan 10 mahasiswa di kelompok kontrol. Peserta mendapatkan penanganan untuk penurunan kecemasan dengan metode berupa future pacing hypnotherapy. Metode analisis data yang digunakan adalah statistik nonparametrik teknik Wilcoxon Signed Rank Test untuk menguji perbedaan skor cemas kelompok subjek saat pretest dan posttest serta Mann Whitney U untuk melihat perbedaan penurunan kecemasan pada kelompok eksperimen dan kelompok kontrol. Hasil Wilcoxon Signed Rank Test menunjukkan bahwa future pacing hypnotherapy efektif dalam menurunkan kecemasan dengan p=0,012. Sedangkan hasil Mann Whitney U menunjukkan bahwa future pacing hypnotherapy efektif dalam menurunkan kecemasan dengan p=0,003 dan kelompok eksperimen mengalami penurunan kecemasan yang lebih besar dengan mean rank = 14,25.Kata kunci : future pacing hypnotherapy, kecemasan, mahasiswa baru

  14. Leading change.

    Science.gov (United States)

    2017-02-27

    In response to feedback from nursing, midwifery and other care staff who wanted to understand better how the Leading Change, Adding Value framework applies to them, NHS England has updated its webpage to include practice examples.

  15. Management of Implantable Cardioverter Defibrillator Recipients: Care Beyond Guidelines.

    Science.gov (United States)

    Philippon, François; Sterns, Laurence D; Nery, Pablo B; Parkash, Ratika; Birnie, David; Rinne, Claus; Mondesert, Blandine; Exner, Derek; Bennett, Matthew

    2017-08-01

    This companion article is intended to address common clinical scenarios in patients with implantable defibrillators that were not addressed in the 2016 Canadian Cardiovascular Society/Canadian Heart Rhythm Society implantable cardioverter defibrillator guidelines including recommendations for device programming to improve detection, to minimize shocks (appropriate and inappropriate), and to minimize ventricular pacing. Important issues at the time of replacement such as device prescription, technical aspects (vascular access, extraction), and management of components on advisories are also discussed. Finally, common clinical scenarios such as management of patients with terminal illnesses, recurrent ventricular tachycardia, electrical storms, catheter ablation for ventricular tachycardia, and system infection management are considered. The management of these patients requires a team approach and comprehensive knowledge surrounding these common clinical scenarios. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  16. Optical effects of ion implantation

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1987-01-01

    The review concerns the effects of ion implantation that specifically relate to the optical properties of insulators. Topics which are reviewed include: ion implantation, ion range and damage distributions, colour centre production by ion implantation, high dose ion implantation, and applications for integrated optics. Numerous examples are presented of both diagnostic and industrial examples of ion implantation effects in insulators. (U.K.)

  17. Implants delivering bisphosphonate locally increase periprosthetic bone density in an osteoporotic sheep model. A pilot study

    Directory of Open Access Journals (Sweden)

    GVA Stadelmann

    2008-07-01

    Full Text Available It is a clinical challenge to obtain a sufficient orthopaedic implant fixation in weak osteoporotic bone. When the primary implant fixation is poor, micromotions occur at the bone-implant interface, activating osteoclasts, which leads to implant loosening. Bisphosphonate can be used to prevent the osteoclastic response, but when administered systemically its bioavailability is low and the time it takes for the drug to reach the periprosthetic bone may be a limiting factor. Recent data has shown that delivering bisphosphonate locally from the implant surface could be an interesting solution. Local bisphosphonate delivery increased periprosthetic bone density, which leads to a stronger implant fixation, as demonstrated in rats by the increased implant pullout force. The aim of the present study was to verify the positive effect on periprosthetic bone remodelling of local bisphosphonate delivery in an osteoporotic sheep model. Four implants coated with zoledronate and two control implants were inserted in the femoral condyle of ovariectomized sheep for 4 weeks. The bone at the implant surface was 50% higher in the zoledronate-group compared to control group. This effect was significant up to a distance of 400µm from the implant surface. The presented results are similar to what was observed in the osteoporotic rat model, which suggest that the concept of releasing zoledronate locally from the implant to increase the implant fixation is not species specific. The results of this trial study support the claim that local zoledronate could increase the fixation of an implant in weak bone.

  18. Fast self paced listening times in syntactic comprehension is aphasia -- implications for deficits

    Directory of Open Access Journals (Sweden)

    Jennifer Michaud

    2015-04-01

    (the DV against corrected self paced listening times in the corresponding words in the baseline sentences (the IV in correct responses. We call the residuals of these regressions “relative corrected listening times.” Relative corrected listening times are based on listening times at points at which task-related operations are similar, and therefore factor out these effects. They also factor out differences in general speed of processing and motor functioning, which determine the intercepts of the regressions. The relative corrected listening times for each participant therefore reflect the time taken by each pwa or control participant to perform the parsing and interpretation operations needed in the experimental sentences, compared to the time taken by the other controls or pwa. We performed these regressions separately in each of the four groups of sentences. We analyzed pwa and controls separately. We analyzed groups and not individuals, because performing these regressions on an individual basis would lead to a mean residual for an experimental sentence type compared to a baseline sentence type that approximates zero in each individual (this is a property of linear regression. We analyzed controls and pwa separately to produce separate estimates of basic speed of processing, decision-making and other processes in controls and pwa. We calculated the normal range of relative corrected listening times for each sentence type group by applying the formula in Crawford and Howell (1998 to the results of the regressions in the controls. We then determined whether the relative corrected listening time for each group of sentences in each pwa was within the normal range of residuals. We focus on a finding that has not previously been reported, which is that, in some pwa, some relative corrected listening times (i.e., residuals of the regression of critical words in experimental sentences against corresponding words in baseline sentences were lower than those seen in

  19. Ion implantation in semiconductors

    International Nuclear Information System (INIS)

    Gusev, V.; Gusevova, M.

    1980-01-01

    The historical development is described of the method of ion implantation, the physical research of the method, its technological solution and practical uses. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material, ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions. (M.S.)

  20. Ion implantation in semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Gusev, V; Gusevova, M

    1980-06-01

    The historical development of the method of ion implantation, the physical research of the method, its technological solution and practical uses is described. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material and ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions.

  1. Trends in Cochlear Implants

    OpenAIRE

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic as...

  2. Wide QRS tachycardia in a patient with pre excitation; what are the pathways involved? Pacing manoeuvres to characterize a unique pathway

    Directory of Open Access Journals (Sweden)

    Krishna Kumar Mohanan Nair

    2017-03-01

    Full Text Available A 30year old patient presented to us with recurrent episodes of palpitation and documented tachycardia. In all his presentations a wide QRS tachycardia was recorded. The baseline ECG showed pre excitation. The 12 lead ECG of the tachycardia and the baseline ECG is shown in Fig. 1A. During EP study the patient had baseline pre excitation and the HV interval was 16 ms. A duo-decapolar halo (HL catheter was used to map right atrium and a decapolar coronary sinus (CS catheter was used to map coronary sinus. In addition a His bundle and right ventricular (RV quadripolar catheters were used. The delta wave morphology was suggestive of a posteroseptal pathway. Ventricular pacing from RV apex showing central decremental conduction with ventriculo-atrial Wenkebach at 290 ms. Ventricular extrastimulation also showed decremental conduction and VA block at S1 S2 of 400,240. The intra cardiac recording of tachycardia and its initiation is shown in Fig. 1B. Pacing from lateral RA (HL 5, 6 electrodes showed progressive pre excitation with extrastimulation and induction of tachycardia. The QRS morphology was same as the patient's clinical tachycardia and the tachycardia cycle length (TCL was 304 ms. An atrial entrainment protocol showed entrainment with the same QRS morphology while pacing from right atrium. The VA interval of the first return cycle was the same as the subsequent VA intervals. A ventricular entrainment protocol showed V-A-V response and post pacing interval of 414 ms. An atrial extra systole was given from the mid CS electrodes (CS 5, 6 – the effect is shown in Fig. 3. In sinus rhythm a parahisian pacing manoeuvre was done as shown in Fig. 4A. What is the mechanism of the tachycardia and what are the pathways involved?

  3. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  4. High energy ion implantation

    International Nuclear Information System (INIS)

    Ziegler, J.F.

    1985-01-01

    High energy ion implantation offers the oppertunity for unique structures in semiconductor processing. The unusual physical properties of such implantations are discussed as well as the special problems in masking and damage annealing. A review is made of proposed circuit structures which involve deep implantation. Examples are: deep buried bipolar collectors fabricated without epitaxy, barrier layers to reduce FET memory sensitivity to soft-fails, CMOS isolation well structures, MeV implantation for customization and correction of completed circuits, and graded reach-throughs to deep active device components. (orig.)

  5. [Silastic implant and synovitis].

    Science.gov (United States)

    Sennwald, G

    1989-07-22

    The silastic implant based on siloxane polymere induces granulomatous synovitis in certain predisposed individuals, a reaction which may continue even after removal of the implant. This is also true of a prosthesis of the trapezium in two of our patients, though to a lesser degree. This is probably the reason why the problem has not yet been widely recognized. The hypothesis is put forward that an enzymatic predisposition may allow chemical degradation of the fragmented silastic implant into a toxic component responsible for the pathologic condition. The slow progression of the lesions is a challenge for the future and puts in question the further use of silastic implants.

  6. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  7. The learning curve associated with the introduction of the subcutaneous implantable defibrillator

    NARCIS (Netherlands)

    R.E. Knops (Reinoud); T.F. Brouwer (Tom F.); C.S. Barr (Craig); D.A.M.J. Theuns (Dominic); L. Boersma (Lucas); R. Weiss (Ram); P. Neuzil (Petr); M.F. Scholten (Marcoen); P.D. Lambiase (Pier); A. Leon (Angel); A.M. Hood (Margaret); P. Jones; Wold, N. (Nicholas); Grace, A.A. (Andrew A.); L.R.A. Olde Nordkamp (Louise R.A.); M.C. Burke (Martin)

    2016-01-01

    textabstractAims: The subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced to overcome complications related to transvenous leads. Adoption of the S-ICD requires implanters to learn a new implantation technique. The aim of this study was to assess the learning curve for S-ICD

  8. Current use of implantable electrical devices in Sweden: data from the Swedish pacemaker and implantable cardioverter-defibrillator registry.

    Science.gov (United States)

    Gadler, Fredrik; Valzania, Cinzia; Linde, Cecilia

    2015-01-01

    The National Swedish Pacemaker and Implantable Cardioverter-Defibrillator (ICD) Registry collects prospective data on all pacemaker and ICD implants in Sweden. We aimed to report the 2012 findings of the Registry concerning electrical devices implantation rates and changes over time, 1 year complications, long-term device longevity and patient survival. Forty-four Swedish implanting centres continuously contribute implantation of pacemakers and ICDs to the Registry by direct data entry on a specific website. Clinical and technical information on 2012 first implants and postoperative complications were analysed and compared with previous years. Patient survival data were obtained from the Swedish population register database. In 2012, the mean pacemaker and ICD first implantation rates were 697 and 136 per million inhabitants, respectively. The number of cardiac resynchronization therapy (CRT) first implantations/million capita was 41 (CRT pacemakers) and 55 (CRT defibrillators), with only a slight increase in CRT-ICD rate compared with 2011. Most device implantations were performed in men. Complication rates for pacemaker and ICD procedures were 5.3 and 10.1% at 1 year, respectively. Device and lead longevity differed among manufacturers. Pacemaker patients were older at the time of first implant and had generally worse survival rate than ICD patients (63 vs. 82% after 5 years). Pacemaker and ICD implantation rates seem to have reached a level phase in Sweden. Implantable cardioverter-defibrillator and CRT implantation rates are very low and do not reflect guideline indications. Gender differences in CRT and ICD implantations are pronounced. Device and patient survival rates are variable, and should be considered when deciding device type. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  9. Radiation beans characterization and implantation for study of lead equivalent individual protection device used in radiodiagnostic practices; Caracterizacao e implantacao de feixes de radiacao para estudo de dispositivos de protecao individual com equivalencia em chumbo utilizados em praticas de radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Leslie Silva

    2004-07-01

    The protective shielding (IPC) must be used by occupationally exposed professionals, patients and volunteers, in order to optimize the doses who receive due to radiological practices. International and national norms establish the methodology to be adopted for determination of the IPC attenuation. In this work, the IPC had been submitted to X-rays beams with known characteristics, standardized for determination of their attenuation equivalent thickness by comparison to an experimental lead attenuation slope. This comparison technique allowed insurance estimative of the IPC attenuation equivalent thickness in mm of lead. Thus, it was possible to verify the conformity of the attenuation equivalent thickness determined experimentally and the value of the thickness indicated by the manufacturer. To carry out this work, it was necessary the implementation of experimental setups stated in the specifics norms, the study of the X-rays beams original features and the determination of combined additional filters, in order to allow the X-ray equipment used operates in compliance with Norm IEC 61331-1 IEC. The radiation quality selected is characterized by a 100 kV voltage and a 0.25 mm of copper overall filtration. The implementation of this radiation quality it was carried through of its first and second HVL (Half Value Layer). Thus, a methodology according to the international Norms has been implemented in the laboratory. The results of the present work provide suitable and useful information about radiation beams features related to the determination techniques of the attenuation properties. Once implemented the procedures for conformity evaluation of the protection devices, it will be possible to carry out specific quality control tests, which will be helpful to manufacturers, customers, as well as authorities in the radiological protection and health areas. (author)

  10. Study of the radiation effect in breast implants

    Energy Technology Data Exchange (ETDEWEB)

    Moreno T, L. R.; Ramirez R, A., E-mail: lumor2000@yahoo.com.mx [Universidad Autonoma Metropolitana, Unidad Azcapotzalco, Departamento de Ciencias Basicas, Av. San Pablo No. 180, Col. Reynosa Tamaulipas, 02200 Mexico D. F. (Mexico)

    2013-10-01

    This breast cancer is one of the most important death causes in women. Among the more frequently medical treatment for advanced breast cancer is the mastectomy. This situation leads to silicone implants as an esthetic option. There have been cases in patients with implants where cancer was frequently detected, in which a conventional radiotherapy is required. In this work is presented a study of the probable adverse effects caused by the application of high power X-rays (6-10 MV) to the silicone implants and to the surrounding tissues. In the research carried out at the clinic, none Bolus effect was detected in patients with implants. Our results prescribe that in the case of patients with implants and frequent breast cancer, the removal of implants is not necessary due radiotherapy works directly in the damaged tissues. (Author)

  11. Study of the radiation effect in breast implants

    International Nuclear Information System (INIS)

    Moreno T, L. R.; Ramirez R, A.

    2013-01-01

    This breast cancer is one of the most important death causes in women. Among the more frequently medical treatment for advanced breast cancer is the mastectomy. This situation leads to silicone implants as an esthetic option. There have been cases in patients with implants where cancer was frequently detected, in which a conventional radiotherapy is required. In this work is presented a study of the probable adverse effects caused by the application of high power X-rays (6-10 MV) to the silicone implants and to the surrounding tissues. In the research carried out at the clinic, none Bolus effect was detected in patients with implants. Our results prescribe that in the case of patients with implants and frequent breast cancer, the removal of implants is not necessary due radiotherapy works directly in the damaged tissues. (Author)

  12. Tardive Dyskinesia, Oral Parafunction, and Implant-Supported Rehabilitation

    Directory of Open Access Journals (Sweden)

    S. Lumetti

    2016-01-01

    Full Text Available Oral movement disorders may lead to prosthesis and implant failure due to excessive loading. We report on an edentulous patient suffering from drug-induced tardive dyskinesia (TD and oral parafunction (OP rehabilitated with implant-supported screw-retained prostheses. The frequency and intensity of the movements were high, and no pharmacological intervention was possible. Moreover, the patient refused night-time splint therapy. A series of implant and prosthetic failures were experienced. Implant failures were all in the maxilla and stopped when a rigid titanium structure was placed to connect implants. Ad hoc designed studies are desirable to elucidate the mutual influence between oral movement disorders and implant-supported rehabilitation.

  13. Implant Therapy in the Esthetic Zone-Surgical Considerations

    Directory of Open Access Journals (Sweden)

    Marković Aleksa

    2016-07-01

    Full Text Available Implant placement in the esthetic zone is a complex procedure and requires a restoration-driven approach. Proper selection of patients and implant together with individual assessment of the risk of esthetic complications are very important. Correct 3D-implant positioning and sufficient bone volume should provide long-term esthetic and function. Esthetic region is a zone in which expectations and possibilities collide. Clinician should bring the important decision on the appropriate time of implant placement. Immediate implant placement is particularly challenging in the esthetic zone. Patient desire for reduced treatment time should be weighed against the possible risk factors. Protocol of immediate implant placement in conditions of unfavourable gingival biotypes, the lack of bone or soft tissue in patients with a high smile line lead to esthetic failure which is very important in the esthetic region.

  14. Ecotoxicology: Lead

    Science.gov (United States)

    Scheuhammer, A.M.; Beyer, W.N.; Schmitt, C.J.; Jorgensen, Sven Erik; Fath, Brian D.

    2008-01-01

    Lead (Pb) is a naturally occurring metallic element; trace concentrations are found in all environmental media and in all living things. However, certain human activities, especially base metal mining and smelting; combustion of leaded gasoline; the use of Pb in hunting, target shooting, and recreational angling; the use of Pb-based paints; and the uncontrolled disposal of Pb-containing products such as old vehicle batteries and electronic devices have resulted in increased environmental levels of Pb, and have created risks for Pb exposure and toxicity in invertebrates, fish, and wildlife in some ecosystems.

  15. Presence of Biofilms on Polyurethane-Coated Breast Implants: Preliminary Results.

    Science.gov (United States)

    Rieger, Ulrich M; Djedovic, Gabriel; Pattiss, Alexander; Raschke, Gregor F; Frei, Reno; Pierer, Gerhard; Trampuz, Andrej

    2016-01-01

    Polyurethane-coated breast implants seem to be associated with lower medium- and long-term capsular contracture rates in comparison to textured or smooth implant surfaces. Although the etiology of capsular contracture is uncertain, bacterial biofilms have been suggested to trigger chronic peri-implant inflammation, eventually leading to capsular contracture. It is unknown whether polyurethane-coated implants are less prone to biofilm colonization than other implant surfaces. We extracted data from patient records included in a prospective cohort between 2008 and 2011. All patients who underwent removal of polyurethane-coated implants were included in this current study and screened for presence of biofilms by sonication. In addition, implant- and patient-related data were analyzed. Of the ten included polyurethane-coated breast implants, six had been inserted for reconstructive purposes and four for aesthetic reasons. The median implant indwelling time was 28.3 mo. Overall, sonication cultures were positive in 50% of implants. Propionibacterium acnes and coagulase-negative staphylococci were the predominant pathogens isolated from biofilm cultures. Like other implant surfaces, polyurethane-coated implants are prone to biofilm colonization. Further investigations are needed to determine why capsular contracture rates seem to be lower in polyurethane implants than in other implant surfaces. Notably, in this study, 40% of the implants were explanted from breasts with severe capsular contracture.

  16. 9. Incidence of tricuspid valve regurgitation following pacemaker/defibrillator lead extraction

    Directory of Open Access Journals (Sweden)

    A. AlFagih

    2016-07-01

    Full Text Available Despite advanced sterile techniques in cardiac device implantations, long-term complications such as wound infections and/or lead-induced endocarditis can develop mandating lead and device extraction. It has been suggested that lead extraction carries a risk of new-onset Tricuspid Regurgitation (TR, or a deterioration of a formerly known regurgitant valve. Yet, there is no enough scientific evidence to our knowledge to back this claim. In this study we aim to explore the risk of TR following lead extraction.We conducted a retrospective chart review in 113 patients whom underwent lead extraction at Prince Sultan Cardiac Center in Saudi Arabia during the period of Jan, 2002 to Jul, 2015. Six patients underwent lead extraction twice, making the total number of extractions to be 119. Of this study cohort, we include 52 cases who had Tricuspid valve function evaluation via Transthoracic Echocardiography (TTE prior to and after device and lead extraction. TR severity was assessed using a grading system as the following; normal, mild, mild-to-moderate, moderate-to-severe, and severe. Worsening or improvement by more than 1 grade was considered clinically significant. TR following lead extraction was examined over a median of 5 months. Of the 52 cases included in this study, 37 (71.2% were males and 15 (28.8% were females, with a mean age of 46 (SD = 18 years. Eleven patients (21.2% experienced worsening of TR (3 had normal functioning valves before extraction, and 8 were known to have TR prior to extraction, 2 (3.8% had improvement, and the majority (75.0% did not experience any significant changes. Compared with those who had no change, average lead duration was higher in the worsening TR group (67.2 vs. 27.9 months. A lead-attached vegetation was detected in 4 out of the 11 patients with TR. Lead type (High-voltage vs. Pacing was not predictive of TR, 5 (45.5% of the patients in the worsening group had high-voltage leads, while the remaining (54

  17. Surface morphologies of He-implanted tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Bannister, M.E., E-mail: bannisterme@ornl.gov [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6371 (United States); Meyer, F.W.; Hijazi, H. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6371 (United States); Unocic, K.A.; Garrison, L.M.; Parish, C.M. [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    2016-09-01

    Surface morphologies of tungsten surfaces, both polycrystalline and single-crystal [1 1 0], were investigated using SEM and FIB/SEM techniques after implantations at elevated surfaces temperatures (1200–1300 K) using well-characterized, mono-energetic He ion beams with a wide range of ion energies (218 eV–250 keV). Nanofuzz was observed on polycrystalline tungsten (PCW) following implantation of 100-keV He ions at a flux threshold of 0.9 × 10{sup 16} cm{sup −2} s{sup −1}, but not following 200-keV implantations with similar fluxes. No nanofuzz formation was observed on single-crystal [1 1 0] tungsten (SCW), despite fluxes exceeding those demonstrated previously to produce nanofuzz on polycrystalline tungsten. Pre-damaging the single-crystal tungsten with implanted C impurity interstitials did not significantly affect the surface morphologies resulting from the high-flux He ion implantations. The main factor leading to the different observed surface structures for the pristine and C-implanted single-crystal W samples appeared to be the peak He ion flux characterizing the different exposures. It was speculated that nanofuzz formation was not observed for any SCW target exposures because of increased incubation fluences required for such targets.

  18. Porous Titanium for Dental Implant Applications

    Directory of Open Access Journals (Sweden)

    Zena J. Wally

    2015-10-01

    Full Text Available Recently, an increasing amount of research has focused on the biological and mechanical behavior of highly porous structures of metallic biomaterials, as implant materials for dental implants. Particularly, pure titanium and its alloys are typically used due to their outstanding mechanical and biological properties. However, these materials have high stiffness (Young’s modulus in comparison to that of the host bone, which necessitates careful implant design to ensure appropriate distribution of stresses to the adjoining bone, to avoid stress-shielding or overloading, both of which lead to bone resorption. Additionally, many coating and roughening techniques are used to improve cell and bone-bonding to the implant surface. To date, several studies have revealed that porous geometry may be a promising alternative to bulk structures for dental implant applications. This review aims to summarize the evidence in the literature for the importance of porosity in the integration of dental implants with bone tissue and the different fabrication methods currently being investigated. In particular, additive manufacturing shows promise as a technique to control pore size and shape for optimum biological properties.

  19. Research on ion implantation in MEMS device fabrication by theory, simulation and experiments

    Science.gov (United States)

    Bai, Minyu; Zhao, Yulong; Jiao, Binbin; Zhu, Lingjian; Zhang, Guodong; Wang, Lei

    2018-06-01

    Ion implantation is widely utilized in microelectromechanical systems (MEMS), applied for embedded lead, resistors, conductivity modifications and so forth. In order to achieve an expected device, the principle of ion implantation must be carefully examined. The elementary theory of ion implantation including implantation mechanism, projectile range and implantation-caused damage in the target were studied, which can be regarded as the guidance of ion implantation in MEMS device design and fabrication. Critical factors including implantations dose, energy and annealing conditions are examined by simulations and experiments. The implantation dose mainly determines the dopant concentration in the target substrate. The implantation energy is the key factor of the depth of the dopant elements. The annealing time mainly affects the repair degree of lattice damage and thus the activated elements’ ratio. These factors all together contribute to ions’ behavior in the substrates and characters of the devices. The results can be referred to in the MEMS design, especially piezoresistive devices.

  20. Current state of knowledge and experts' perspective on the subcutaneous implantable cardioverter-defibrillator.

    Science.gov (United States)

    Santini, Massimo; Cappato, Riccardo; Andresen, Dietrich; Brachmann, Johannes; Davies, D Wyn; Cleland, John; Filippi, Alessandro; Gronda, Edoardo; Hauer, Richard; Steinbeck, Gerhard; Steinhaus, David

    2009-06-01

    ICD implantation is today a well-recognized therapy to prevent sudden cardiac death. The available implantable devices at present need the use of permanent endocavitary leads which may cause, in some instances, serious troubles to the patients (lead dislodgement, ventricular perforation, lead infections, etc.). A new implantable defibrillator provided by only a subcutaneous lead is at present under evaluation. Its potential indications, usefulness benefits, and problems represent an interesting field of investigation and discussion. This paper describes the conclusions recently reached by a panel of experts, with regard to the potential role of an implantable subcutaneous defibrillator in the prevention of sudden cardiac death.

  1. Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy.

    Science.gov (United States)

    Sticherling, Christian; Müller, Dirk; Schaer, Beat A; Krüger, Silke; Kolb, Christof

    2018-03-27

    Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  2. Kinematic hand parameters in front crawl at different paces of swimming.

    Science.gov (United States)

    Samson, Mathias; Monnet, Tony; Bernard, Anthony; Lacouture, Patrick; David, Laurent

    2015-11-05

    The aim of this study was to investigate the evolution of kinematic hand parameters (sweepback angle, angle of attack, velocity, acceleration and orientation of the hand relative to the absolute coordinate system) throughout an aquatic stroke and to study the possible modifications caused by a variation of the swimming pace. Seventeen competitive swimmers swam at long distance, middle distance and sprint paces. Parameters were calculated from the trajectory of seven markers on the hand measured with an optoelectronic system. Results showed that kinematic hand parameters evolve differently depending on the pace. Angle of attack, sweepback angle, acceleration and orientation of the hand do not vary significantly. The velocity of the hand increases when the pace increases, but only during the less propulsive phases (entry and stretch and downsweep to catch). The more the pace increases and the more the absolute durations of the entry and stretch and downsweep to catch phases decrease. Absolute durations of the insweep and upsweep phases remain constant. During these phases, the propulsive hand forces calculated do not vary significantly when the pace increases. The increase of swimming pace is then explained by the swimmer's capacity to maintain propulsive phases rather than increasing the force generation within each cycle. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Leading men

    DEFF Research Database (Denmark)

    Bekker-Nielsen, Tønnes

    2016-01-01

    Through a systematic comparison of c. 50 careers leading to the koinarchate or high priesthood of Asia, Bithynia, Galatia, Lycia, Macedonia and coastal Pontus, as described in funeral or honorary inscriptions of individual koinarchs, it is possible to identify common denominators but also disting...

  4. Will the Conscious-Subconscious Pacing Quagmire Help Elucidate the Mechanisms of Self-Paced Exercise? New Opportunities in Dual Process Theory and Process Tracing Methods.

    Science.gov (United States)

    Micklewright, Dominic; Kegerreis, Sue; Raglin, John; Hettinga, Florentina

    2017-07-01

    The extent to which athletic pacing decisions are made consciously or subconsciously is a prevailing issue. In this article we discuss why the one-dimensional conscious-subconscious debate that has reigned in the pacing literature has suppressed our understanding of the multidimensional processes that occur in pacing decisions. How do we make our decisions in real-life competitive situations? What information do we use and how do we respond to opponents? These are questions that need to be explored and better understood, using smartly designed experiments. The paper provides clarity about key conscious, preconscious, subconscious and unconscious concepts, terms that have previously been used in conflicting and confusing ways. The potential of dual process theory in articulating multidimensional aspects of intuitive and deliberative decision-making processes is discussed in the context of athletic pacing along with associated process-tracing research methods. In attempting to refine pacing models and improve training strategies and psychological skills for athletes, the dual-process framework could be used to gain a clearer understanding of (1) the situational conditions for which either intuitive or deliberative decisions are optimal; (2) how intuitive and deliberative decisions are biased by things such as perception, emotion and experience; and (3) the underlying cognitive mechanisms such as memory, attention allocation, problem solving and hypothetical thought.

  5. Biventricular pacemaker implantation with the BV Pulsera

    Energy Technology Data Exchange (ETDEWEB)

    Wright, J.D.W.; Todd, D.; Waktare, J.E.P.; Hughes, S.; Abell, C. [The Cardiothoracic Centre, Liverpool (United Kingdom)

    2005-07-01

    The BV Pulsera mobile X-ray system is used for biventricular pacemaker implantation in a surgical environment. It provides high-quality images of the moving structures, including the fine coronary leads, and can be used for long fluoroscopy runs without overheating. (orig.)

  6. Biventricular pacemaker implantation with the BV Pulsera

    International Nuclear Information System (INIS)

    Wright, J.D.W.; Todd, D.; Waktare, J.E.P.; Hughes, S.; Abell, C.

    2005-01-01

    The BV Pulsera mobile X-ray system is used for biventricular pacemaker implantation in a surgical environment. It provides high-quality images of the moving structures, including the fine coronary leads, and can be used for long fluoroscopy runs without overheating. (orig.)

  7. A Closer Look at Split Visual Attention in System- and Self-Paced Instruction in Multimedia Learning

    Science.gov (United States)

    Schmidt-Weigand, Florian; Kohnert, Alfred; Glowalla, Ulrich

    2010-01-01

    Two experiments examined visual attention distribution in learning from text and pictures. Participants watched a 16-step multimedia instruction on the formation of lightning. In Experiment 1 (N=90) the instruction was system-paced (fast, medium, slow pace), while it was self-paced in Experiment 2 (N=31). In both experiments the text modality was…

  8. Percutaneous and skeletal biocarbon implants

    Science.gov (United States)

    Mooney, V.

    1977-01-01

    Review of carbon implants developed by NASA discussed four different types of implants and subsequent improvements. Improvements could be of specific interest to rehabilitation centers and similar organizations.

  9. Degradable Implantate: Entwicklungsbeispiele

    Science.gov (United States)

    Ruffieux, Kurt; Wintermantel, Erich

    Resorbierbare Implantate werden seit mehreren Jahrzehnten in der Implantologie eingesetzt. Bekannt wurden diese Biomaterialien mit dem Aufkommen von sich selbst auflösenden Nahtfäden auf der Basis von synthetisch hergestellten Polylactiden und Polyglycoliden in den 70er Jahren. In einem nächsten Schritt wurden Implantate wie Platten und Schrauben zur Gewebefixation aus den gleichen Biomaterialien hergestellt.

  10. Risks of Breast Implants

    Science.gov (United States)

    ... have a risk of developing a type of cancer called breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) in the breast tissue surrounding the implant. BIA-ALCL is not breast cancer. Women diagnosed with BIA-ALCL may need to ...

  11. Ion implantation of metals

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1976-01-01

    In this part of the paper descriptions are given of the effects of ion implantation on (a) friction and wear in metals; and (b) corrosion of metals. In the study of corrosion, ion implantation can be used either to introduce a constituent that is known to convey corrosion resistance, or more generally to examine the parameters which control corrosion. (U.K.)

  12. Ion implantation into diamond

    International Nuclear Information System (INIS)

    Sato, Susumu

    1994-01-01

    The graphitization and the change to amorphous state of diamond surface layer by ion implantation and its characteristics are reported. In the diamond surface, into which more than 10 16 ions/cm 2 was implanted, the diamond crystals are broken, and the structure changes to other carbon structure such as amorphous state or graphite. Accompanying this change of structure, the electric conductivity of the implanted layer shows two discontinuous values due to high resistance and low resistance. This control of structure can be done by the temperature of the base during the ion implantation into diamond. Also it is referred to that by the base temperature during implantation, the mutual change of the structure between amorphous state and graphite can be controlled. The change of the electric resistance and the optical characteristics by the ion implantation into diamond surface, the structural analysis by Raman spectroscopy, and the control of the structure of the implanted layer by the base temperature during implantation are reported. (K.I.)

  13. An Investigation on Exhaustion of SAP ERP Users: Influence of Pace of Change and Technostress

    Directory of Open Access Journals (Sweden)

    Prashanta Kumar Roy

    2017-10-01

    Full Text Available Despite recent growing research interest on ERP research, the understanding on ERP induced exhaustion is still limited. This study examines how the pace of change of ERP functionalities and interface causes exhaustion in workplace. For this purpose, we conducted an investigation on 128 ERP users from two different organizations in Bangladesh. We extended theory of technostress by integrating pace of change of ERP system. Result suggests that pace of change on ERP system significantly affect work-overload, work-life conflict and role ambiguity on ERP users. Result also shows that work-overload and role ambiguity are strong predictors for ERP induced exhaustion.

  14. Earlier Right Ventricular Pacing in Cardiac Resynchronization Therapy for a Patient with Right Axis Deviation.

    Science.gov (United States)

    Hattori, Yusuke; Ishibashi, Kohei; Noda, Takashi; Okamura, Hideo; Kanzaki, Hideaki; Anzai, Toshihisa; Yasuda, Satoshi; Kusano, Kengo

    2017-09-01

    We describe the case of a 37-year-old woman who presented with complete right bundle branch block and right axis deviation. She was admitted to our hospital due to severe heart failure and was dependent on inotropic agents. Cardiac resynchronization therapy was initiated but did not improve her condition. After the optimization of the pacing timing, we performed earlier right ventricular pacing, which led to an improvement of her heart failure. Earlier right ventricular pacing should be considered in patients with complete right bundle branch block and right axis deviation when cardiac resynchronization therapy is not effective.

  15. Sawtooth Pacing by Real-Time Auxiliary Power Control in a Tokamak Plasma

    International Nuclear Information System (INIS)

    Goodman, T. P.; Felici, F.; Sauter, O.; Graves, J. P.

    2011-01-01

    In the standard scenario of tokamak plasma operation, sawtooth crashes are the main perturbations that can trigger performance-degrading, and potentially disruption-generating, neoclassical tearing modes. This Letter demonstrates sawtooth pacing by real-time control of the auxiliary power. It is shown that the sawtooth crash takes place in a reproducible manner shortly after the removal of that power, and this can be used to precisely prescribe, i.e., pace, the individual sawteeth. In combination with preemptive stabilization of the neoclassical tearing modes, sawtooth pacing provides a new sawtooth control paradigm for improved performance in burning plasmas.

  16. Microleakage at the Different Implant Abutment Interface: A Systematic Review

    Science.gov (United States)

    Chowdhary, Ramesh; Kumari, Shail

    2017-01-01

    Introduction Presence of gap at the implant-abutment interface, leads to microleakage and accumulation of bacteria which can affect the success of dental implants. Aim To evaluate the sealing capability of different implant connections against microleakage. Materials and Methods In January 2017 an electronic search of literature was performed, in Medline, EBSCO host and Pubmed data base. The search was focused on ability of different implant connections in preventing microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full text reading. Results In this systematic review, literature search initially resulted in 78 articles among which 30 articles only fulfilled the criteria for inclusion and were finally included in the review. Almost all the studies showed that there was some amount of microleakage at abutment implant interface. Microleakage was very less in Morse taper implants in comparison to other implant connections. Majority of studies showed less microleakage in static loading conditions and microleakage increases in dynamic loading conditions. Conclusion In this systematic review maximum studies showed that there was some amount of microleakage at abutment implant interface. External hexagon implants failed completely to prevent microleakage in both static and dynamic loading conditions of implants. Internal hexagon implants mainly internal conical (Morse taper) implants are very promising in case of static loading and also showed less microleakage in dynamic loading conditions. Torque recommended by manufacturer should be followed strictly to get a better seal at abutment implant interface. Zirconia abutments are more to microleakage than Titanium abutments and there use should be discouraged. Zirconia abutments should be only restricted to cases where there was very high demand of aesthetics. PMID:28764310

  17. What Does Music Sound Like for a Cochlear Implant User?

    Science.gov (United States)

    Jiam, Nicole T; Caldwell, Meredith T; Limb, Charles J

    2017-09-01

    Cochlear implant research and product development over the past 40 years have been heavily focused on speech comprehension with little emphasis on music listening and enjoyment. The relatively little understanding of how music sounds in a cochlear implant user stands in stark contrast to the overall degree of importance the public places on music and quality of life. The purpose of this article is to describe what music sounds like to cochlear implant users, using a combination of existing research studies and listener descriptions. We examined the published literature on music perception in cochlear implant users, particularly postlingual cochlear implant users, with an emphasis on the primary elements of music and recorded music. Additionally, we administered an informal survey to cochlear implant users to gather first-hand descriptions of music listening experience and satisfaction from the cochlear implant population. Limitations in cochlear implant technology lead to a music listening experience that is significantly distorted compared with that of normal hearing listeners. On the basis of many studies and sources, we describe how music is frequently perceived as out-of-tune, dissonant, indistinct, emotionless, and weak in bass frequencies, especially for postlingual cochlear implant users-which may in part explain why music enjoyment and participation levels are lower after implantation. Additionally, cochlear implant users report difficulty in specific musical contexts based on factors including but not limited to genre, presence of lyrics, timbres (woodwinds, brass, instrument families), and complexity of the perceived music. Future research and cochlear implant development should target these areas as parameters for improvement in cochlear implant-mediated music perception.

  18. Number of implants for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  19. New approaches to determine fatigue in elite athletes during intensified training: Resting metabolic rate and pacing profile.

    Directory of Open Access Journals (Sweden)

    Amy L Woods

    Full Text Available Elite rowers complete a high volume of training across a number of modalities to prepare for competition, including periods of intensified load, which may lead to fatigue and short-term performance decrements. As yet, the influence of substantial fatigue on resting metabolic rate (RMR and exercise regulation (pacing, and their subsequent utility as monitoring parameters, has not been explicitly investigated in elite endurance athletes.Ten National-level rowers completed a four-week period of intensified training. RMR, body composition and energy intake were assessed PRE and POST the four-week period using indirect calorimetry, Dual-Energy X-Ray Densitometry (DXA, and three-day food diary, respectively. On-water rowing performance and pacing strategy was evaluated from 5 km time trials. Wellness was assessed weekly using the Multicomponent Training Distress Scale (MTDS.Significant decreases in absolute (mean ± SD of difference, p-value: -466 ± 488 kJ.day-1, p = 0.01 and relative RMR (-8.0 ± 8.1 kJ.kg.FFM-1, p = 0.01 were observed. Significant reductions in body mass (-1.6 ± 1.3 kg, p = 0.003 and fat mass (-2.2 ± 1.2 kg, p = 0.0001 were detected, while energy intake was unchanged. On-water 5 km rowing performance worsened (p < 0.05 and an altered pacing strategy was evident. Fatigue and total mood disturbance significantly increased across the cycle (p < 0.05, and trends were observed for reduced vigour and increased sleep disturbance (p < 0.1.Four weeks of heavy training decreased RMR and body composition variables in elite rowers and induced substantial fatigue, likely related to an imbalance between energy intake and output. This study demonstrates that highly experienced athletes do not necessarily select the correct energy intake during periods of intensified training, and this can be assessed by reductions in RMR and body composition. The shortfall in energy availability likely affected recovery from training and altered 5 km time trial

  20. Ion implantation into iron

    International Nuclear Information System (INIS)

    Iwaki, Masaya

    1978-01-01

    The distribution of implanted ions in iron, the friction characteristics and the corrosion of iron were studied. The distribution of Ni or Cr ions implanted into mild steel was measured. The accelerated voltage was 150 keV, and the beam current density was about 2 microampere/cm 2 . The measurement was made with an ion microanalyzer. The measured distribution was compared with that of LSS theory. Deep invasion of Ni was seen in the measured distribution. The distribution of Cr ions was different from the distribution calculated by the LSS theory. The relative friction coefficient of mild steel varied according to the dose of implanted Cu or N ions, and to the accelerating voltage. Formation of compound metals on the surfaces of metals by ion-implantation was investigated for the purpose to prevent the corrosion of metals. The resistance of mild steel in which Ni ions were implanted was larger than that of mild steel without any treatment. (Kato, T.)

  1. Evolutionary traces decode molecular mechanism behind fast pace of myosin XI

    Directory of Open Access Journals (Sweden)

    Syamaladevi Divya P

    2011-09-01

    Full Text Available Abstract Background Cytoplasmic class XI myosins are the fastest processive motors known. This class functions in high-velocity cytoplasmic streaming in various plant cells from algae to angiosperms. The velocities at which they process are ten times faster than its closest class V homologues. Results To provide sequence determinants and structural rationale for the molecular mechanism of this fast pace myosin, we have compared the sequences from myosin class V and XI through Evolutionary Trace (ET analysis. The current study identifies class-specific residues of myosin XI spread over the actin binding site, ATP binding site and light chain binding neck region. Sequences for ET analysis were accumulated from six plant genomes, using literature based text search and sequence searches, followed by triple validation viz. CDD search, string-based searches and phylogenetic clustering. We have identified nine myosin XI genes in sorghum and seven in grape by sequence searches. Both the plants possess one gene product each belonging to myosin type VIII as well. During this process, we have re-defined the gene boundaries for three sorghum myosin XI genes using fgenesh program. Conclusion Molecular modelling and subsequent analysis of putative interactions involving these class-specific residues suggest a structural basis for the molecular mechanism behind high velocity of plant myosin XI. We propose a model of a more flexible switch I region that contributes to faster ADP release leading to high velocity movement of the algal myosin XI.

  2. Relationships between triathlon performance and pacing strategy during the run in an international competition.

    Science.gov (United States)

    Le Meur, Yann; Bernard, Thierry; Dorel, Sylvain; Abbiss, Chris R; Honnorat, Gérard; Brisswalter, Jeanick; Hausswirth, Christophe

    2011-06-01

    The purpose of the present study was to examine relationships between athlete's pacing strategies and running performance during an international triathlon competition. Running split times for each of the 107 finishers of the 2009 European Triathlon Championships (42 females and 65 males) were determined with the use of a digital synchronized video analysis system. Five cameras were placed at various positions of the running circuit (4 laps of 2.42 km). Running speed and an index of running speed variability (IRSVrace) were subsequently calculated over each section or running split. Mean running speed over the first 1272 m of lap 1 was 0.76 km·h-1 (+4.4%) and 1.00 km·h-1 (+5.6%) faster than the mean running speed over the same section during the three last laps, for females and males, respectively (P international competitions, even if high levels of motivation and direct opponents lead them to adopt an aggressive strategy.

  3. Who Leads China's Leading Universities?

    Science.gov (United States)

    Huang, Futao

    2017-01-01

    This study attempts to identify the major characteristics of two different groups of institutional leaders in China's leading universities. The study begins with a review of relevant literature and theory. Then, there is a brief introduction to the selection of party secretaries, deputy secretaries, presidents and vice presidents in leading…

  4. Cryoablation of focal tachycardia originating from the right atrial free wall during upstream phrenic pacing to avoid phrenic nerve injury.

    Science.gov (United States)

    Johnsrude, Christopher

    2015-01-01

    Recognition of the potential for phrenic nerve injury (PNI) often prompts less aggressive attempts at catheter ablation of multiple forms of tachycardia or abandoning ablation altogether. Some novel techniques to avoid PNI during catheter ablation have been described. Five patients (age: 13-57 years, three females) with ectopic atrial tachycardia originating from the right atrial free wall (RAFW) near the phrenic nerve underwent electrophysiology study with three-dimensional mapping and endocardial cryoablation. Upstream phrenic pacing was performed after cryoadherence was achieved, and cryoablation of ectopic foci was performed during close observation for occurrence of PNI and tachycardia elimination. Cryoablation acutely eliminated five of six atrial tachycardias originating close to the phrenic nerve. Transient PNI during cryothermy occurred in two patients, and resolved within 3 minutes. Patients were observed overnight on telemetry, with no early recurrences of targeted atrial tachycardias and no evidence of PNI. At last follow-up of 1-39 months, four patients were arrhythmia free on no medications. Catheter cryoablation during simultaneous upstream phrenic nerve pacing can lead to safe and effective elimination of focal atrial tachycardias originating from the RAFW close to the phrenic nerve. ©2014 Wiley Periodicals, Inc.

  5. To pace or not to pace: a pilot study of four- and five-gaited Icelandic horses homozygous for the DMRT3 'Gait Keeper' mutation.

    Science.gov (United States)

    Jäderkvist Fegraeus, K; Hirschberg, I; Árnason, T; Andersson, L; Velie, B D; Andersson, L S; Lindgren, G

    2017-12-01

    The Icelandic horse is a breed known mainly for its ability to perform the ambling four-beat gait 'tölt' and the lateral two-beat gait pace. The natural ability of the breed to perform these alternative gaits is highly desired by breeders. Therefore, the discovery that a nonsense mutation (C>A) in the DMRT3 gene was the main genetic factor for horses' ability to perform gaits in addition to walk, trot and canter was of great interest. Although several studies have demonstrated that homozygosity for the DMRT3 mutation is important for the ability to pace, only about 70% of the homozygous mutant (AA) Icelandic horses are reported to pace. The aim of the study was to genetically compare four- and five-gaited (i.e. horses with and without the ability to pace) AA Icelandic horses by performing a genome-wide association (GWA) analysis. All horses (n = 55) were genotyped on the 670K Axiom Equine Genotyping Array, and a GWA analysis was performed using the genabel package in r. No SNP demonstrated genome-wide significance, implying that the ability to pace goes beyond the presence of a single gene variant. Despite its limitations, the current study provides additional information regarding the genetic complexity of pacing ability in horses. However, to fully understand the genetic differences between four- and five-gaited AA horses, additional studies with larger sample materials and consistent phenotyping are needed. © 2017 Stichting International Foundation for Animal Genetics.

  6. Venous Obstruction Following Pacemaker or Implantable Cardioverter-Defibrillator Implantation, Mini Review

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Akbarzadeh

    2016-08-01

    Full Text Available Venous obstruction is relatively frequent following permanent pacemaker or implantable cardioverter-defibrillator (ICD implantation. However, most of them are asymptomatic. Although the exact risk factor for this complication is not known, number of leads, heart failure and infection may prone the patient to this complication. The goal standard for detection of vein stenosis is venography; however, ultrasound sonography has an acceptable accuracy. Anticoagulant therapy may be considered for symptomatic patients. For device upgrading, non-functional leads removal, venoplasty and rarely surgical treatment may be indicated.

  7. Melting, growth, and faceting of lead precipitates in aluminum

    DEFF Research Database (Denmark)

    Gråbæk, L.; Bohr, J.; Andersen, H.H.

    1992-01-01

    Aluminum single crystals cut in the direction were implanted with 2 x 10(20) m-2 Pb+ ions at 75 or 150 keV. The implanted insoluble lead precipitated as epitaxially oriented crystallites in the aluminum matrix. The precipitates were studied by x-ray diffraction at Riso, DESY, and Brookhaven...

  8. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  9. Adverse effects of permanent atrial fibrillation on heart failure in patients with preserved left ventricular function and chronic right apical pacing for complete heart block.

    Science.gov (United States)

    Lampe, Brigitte; Hammerstingl, Christoph; Schwab, Jörg Otto; Mellert, Fritz; Stoffel-Wagner, Birgit; Grigull, Andreas; Fimmers, Rolf; Maisch, Bernhard; Nickenig, Georg; Lewalter, Thorsten; Yang, Alexander

    2012-10-01

    The impact of atrial fibrillation (AF) on heart failure (HF) was evaluated in patients with preserved left ventricular (LV) function and long-term right ventricular (RV) pacing for complete heart block. Clinical, echocardiographic, and laboratory parameters of HF were assessed in 35 patients with established AF who had undergone ablation of the atrioventricular node and pacemaker implantation (Group A) and 31 patients who received dual-chamber pacing for spontaneous complete heart block (Group B). During a follow-up period of 12.7 ± 7.5 years, New York Heart Association (NYHA) functional class increased from 1.3 ± 0.5 to 2.1 ± 0.6 (p Left ventricular ejection fraction (LVEF) decreased from 59.7 ± 5.1 to 53.0 ± 8.2 (p function were moderately depressed in Group A compared with those in Group B: NYHA class 2.1 ± 0.6 versus 1.6 ± 0.7, p = 0.001; LVEF 53.0 ± 8.2 versus 56.9 ± 7.0 %, p brain natriuretic peptide (NT-proBNP) 1116.8 ± 883.9 versus 622.9 ± 1059.4 pg/ml, p 10 %, increasing NYHA class ≥1, and NT-proBNP levels >1,000 pg/ml. Permanent AF was associated with adverse effects on LV function and symptoms of HF in patients with long-term RV pacing for complete heart block, and appears to play an important role in the development of HF in this specific patient cohort.

  10. Correlation between MRI results and intraoperative findings in patients with silicone breast implants.

    Science.gov (United States)

    Lindenblatt, Nicole; El-Rabadi, Karem; Helbich, Thomas H; Czembirek, Heinrich; Deutinger, Maria; Benditte-Klepetko, Heike

    2014-01-01

    Silicone gel breast implants may silently rupture without detection. This has been the main reason for magnetic resonance imaging (MRI) of the augmented or reconstructed breast. The aim of the present study was to investigate the accuracy of MRI for implant rupture. Fifty consecutive patients with 85 silicone gel implants were included in the study. The mean age of the patients was 51 (range 21-72) years, with a mean duration of implantation of 3.8 (range 1-28) years. All patients underwent clinical examination and breast MRI. Intraoperative implant rupture was diagnosed by the operating surgeon. Nineteen of the 50 patients suffered from clinical symptoms. An implant rupture was diagnosed by MRI in 22 of 85 implants (26%). In seven of 17 removed implants (41%), the intraoperative diagnosis corresponded with the positive MRI result. However, only 57% of these patients were symptomatic. Ultrasound imaging of the harvested implants showed signs of interrupted inner layers of the implant despite integrity of the outer shell. By microsurgical separation of the different layers of the implant shell, we were able to reproduce this phenomenon and to produce signs of implant rupture on MRI. Our results show that rupture of only the inner layers of the implant shell with integrity of the outer shell leads to a misdiagnosis on MRI. Correlation with clinical symptoms and the specific wishes of the patient should guide the indication for implant removal.

  11. Effects of postshock atrial pacing on atrial defibrillation outcome in the isolated sheep heart

    NARCIS (Netherlands)

    Skanes, A. C.; Gray, R. A.; Zuur, C. L.; Jalife, J.

    1998-01-01

    BACKGROUND: Failed atrial defibrillation shocks are associated with organization of postshock activity and a substantial postshock electrical quiescence. We investigated the ability of a train of pacing stimuli to capture or locally entrain atrial myocardium during the quiescent period after

  12. Photovoltaics (PV) as an Eligible Measure in Residential PACE Programs: Benefits and Challenges (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J.

    2010-06-01

    Property Assessed Clean Energy (PACE) financing is one of several new financial models broadening access to clean energy by addressing the barrier of initial capital cost. The majority of the PACE programs in the market today include PV as an eligible measure. PV appeals to homeowners as a way to reduce utility bills, self-generate sustainable power, increase energy independence and demonstrate a commitment to the environment. If substantial state incentives for PV exist, PV projects can be economic under PACE, especially when partnered with good net metering policies. At the same time, PV is expensive relative to other eligible measures with a return on investment horizon that might exceed program targets. This fact sheet reviews the benefits and potential challenges of including PV in PACE programs.

  13. PACE and the Medicare+Choice risk-adjusted payment model.

    Science.gov (United States)

    Temkin-Greener, H; Meiners, M R; Gruenberg, L

    2001-01-01

    This paper investigates the impact of the Medicare principal inpatient diagnostic cost group (PIP-DCG) payment model on the Program of All-Inclusive Care for the Elderly (PACE). Currently, more than 6,000 Medicare beneficiaries who are nursing home certifiable receive care from PACE, a program poised for expansion under the Balanced Budget Act of 1997. Overall, our analysis suggests that the application of the PIP-DCG model to the PACE program would reduce Medicare payments to PACE, on average, by 38%. The PIP-DCG payment model bases its risk adjustment on inpatient diagnoses and does not capture adequately the risk of caring for a population with functional impairments.

  14. Effects of Bepridil on Atrial Electrical Remodeling in Short-Term Rapid Pacing

    Directory of Open Access Journals (Sweden)

    Hiroto Tsuchiya, MD

    2009-01-01

    Conclusions: Bepridil prevented the shortening of the ERP and MAPD90 induced by rapid atrial pacing in the acute phase. The results of this study might explain the efficacy of bepridil for preventing the recurrence of paroxysmal AF.

  15. EFFECT OF ADAPTIVE PACED CARDIOLOCOMOTOR SYNCHRONIZATION DURING RUNNING: A PRELIMINARY STUDY

    Directory of Open Access Journals (Sweden)

    Bill Phillips

    2013-09-01

    Full Text Available Cardiolocomotor synchronization (CLS has been well established for individuals engaged in rhythmic activity, such as walking, running, or cycling. When frequency of the activity is at or near the heart rate, entrainment occurs. CLS has been shown in many cases to improve the efficiency of locomotor activity, improving stroke volume, reducing blood pressure variability, and lowering the oxygen uptake (VO2. Instead of a 1:1 frequency ratio of activity to heart rate, an investigation was performed to determine if different harmonic coupling at other simple integer ratios (e.g. 1:2, 2:3, 3:2 could achieve any performance benefits. CLS was ensured by pacing the stride rate according to the measured heartbeat (i.e., adaptive paced CLS, or forced CLS. An algorithm was designed that determined the simplest ratio (lowest denominator that, when multiplied by the heart rate will fall within an individualized, predetermined comfortable pacing range for the user. The algorithm was implemented on an iPhone 4, which generated a 'tick-tock' sound through the iPhone's headphones. A sham-controlled crossover study was performed with 15 volunteers of various fitness levels. Subjects ran a 3 mile (4.83 km simulated training run at their normal pace on two consecutive days (randomized one adaptive pacing, one sham. Adaptive pacing resulted in faster runs run times, with subjects running an average of 26:03 ± 3:23 for adaptive pacing and 26:38 ± 3:31 for sham (F = 5.46, p < 0.05. The increase in heart rate from the start of the race as estimated by an exponential time constant was significantly longer during adaptive pacing, τ = 0.99 ± 0.30, compared to sham, τ = 1.53 ± 0.34 (t = -6.62, p < 0.01. Eighty-seven percent of runners found it easy to adjust their stride length to match the pacing signal with seventy-nine percent reporting that pacing helped their performance. These results suggest that adaptive paced CLS may have a beneficial effect on running

  16. Implants for orthodontic anchorage

    Science.gov (United States)

    Zheng, Xiaowen; Sun, Yannan; Zhang, Yimei; Cai, Ting; Sun, Feng; Lin, Jiuxiang

    2018-01-01

    Abstract Implantanchorage continues to receive much attention as an important orthodontic anchorage. Since the development of orthodontic implants, the scope of applications has continued to increase. Although multiple reviews detailing implants have been published, no comprehensive evaluations have been performed. Thus, the purpose of this study was to comprehensively evaluate the effects of implants based on data published in review articles. An electronic search of the Cochrane Library, Medline, Embase, Ebsco and Sicencedirect for reviews with “orthodontic” and “systematic review or meta analysis” in the title, abstract, keywords, or full text was performed. A subsequent manual search was then performed to identify reviews concerning orthodontic implants. A manual search of the orthodontic journals American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), European Journal of Orthodontics (EJO), and Angle Othodontist was also performed. Such systematic reviews that evaluated the efficacy and safety of orthodontic implants were used to indicate success rates and molar movements. A total of 23 reviews were included in the analysis. The quality of each review was assessed using a measurement tool for Assessment of Multiple Systematic Reviews (AMSTAR), and the review chosen to summarize outcomes had a quality score of >6. Most reviews were less than moderate quality. Success rates of implants ranged in a broad scope, and movement of the maxillary first molar was superior with implants compared with traditional anchorage. PMID:29595673

  17. Maintenance in dental implants

    Directory of Open Access Journals (Sweden)

    Giselle Póvoa Gomes

    2008-01-01

    Full Text Available In implants, maintenance is a decisive factor for obtaining success when implant supported overdentures and dentures are used. The present stud presents, a clinical case of a patient, a 70 year-old white man, with a completely edentulous mandibular alveolar ridge, severe bone resorption with presence of basal bone only, and absence of vestibule. Initially, treatment consisted of the placement of a mandibular overdenture, supported on three implants in the anterior inter-foramen region, as the left implant was transfixed in the basal bone of 2 to 3 millimeters. Eleven years later, another two implants were placed in the anterior area and an immediate load was performed up to the first molars, for the placement of an implant supported fixed. Throughout the entire treatment, meticulous maintenance was carried out, with follow-up for fourteen years, interrupted by the patient’s death. From the third month after the opening the three implants initially placed, the presence of keratinized mucosa, definition of the vestibule, maturation of the alveolar ridge and bone formation in the mento region were observed. It was concluded that good planning, allied to mastery of the technique and adequate maintenance were the prerequisites necessary for obtaining favorable results, success of the present case, and for the patient to have a better quality of life.

  18. Interatrial septum versus right atrial appendage pacing for prevention of atrial fibrillation : A meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Zhang, L; Jiang, H; Wang, W; Bai, J; Liang, Y; Su, Y; Ge, J

    2017-07-28

    Interatrial septum (IAS) pacing seems to be a promising strategy for the prevention of atrial fibrillation (AF); however, studies have yielded conflicting results. This meta-analysis was to compare IAS with right atrial appendage (RAA) pacing on the prevention of postpacing AF occurrence. Pubmed, MEDLINE, EMBASE and Web of Science databases were searched through October 2016 for randomized controlled trials comparing IAS with RAA pacing on the prevention of AF. Data concerning study design, patient characteristics and outcomes were extracted. Risk ratio (RR), weighted mean differences (WMD) or standardized mean differences (SMD) were calculated using fixed or random effects models. A total of 12 trials involving 1146 patients with dual-chamber pacing were included. Although IAS was superior to RAA pacing in terms of reducing the number of AF episodes (SMD = -0.29, P = 0.05), AF burden (SMD = -0.41, P = 0.008) and P -wave duration (WMD = -34.45 ms, P IAS pacing. Nevertheless, no differences were observed concerning all-cause death (RR = 1.04, P = 0.88), procedure-related events (RR = 1.17, P = 0.69) and pacing parameters between IAS and RAA pacing in the follow-up period. IAS pacing is safe and as well tolerated as RAA pacing. Although IAS pacing may fail to prevent permanent AF occurrence and recurrences of AF, it is able to not only improve interatrial conduction, but also reduce AF burden.

  19. Infants' Visual Attention to Baby DVDs as a Function of Program Pacing

    Science.gov (United States)

    Gola, Alice Ann Howard; Calvert, Sandra L.

    2011-01-01

    This study examined the effects of program pacing, defined as the rate of scene and character change per minute, on infants' visual attention to video presentations. Seventy-two infants (twenty-four 6-month-olds, twenty-four 9-month-olds, twenty-four 12-month-olds) were exposed to one of two sets of high- and low-paced commercial infant DVDs. Each…

  20. On the pace of fertility decline in sub-Saharan Africa

    OpenAIRE

    David Shapiro; Andrew Hinde

    2017-01-01

    Background: This descriptive finding examines the comparative pace of fertility decline in sub-Saharan Africa, relative to Asia, Latin America and the Caribbean, and Northern Africa.Objective: We seek to determine if fertility decline has been slower in sub-Saharan Africa than elsewhere in the developing world.Methods: United Nations 2017 estimates of national fertility are used in assessing the comparative pace of fertility decline, and the four regions are compared in terms of how far they ...