WorldWideScience

Sample records for p-n counters

  1. Proportional Counter Calibration and Analysis for 12C + p Resonance Scattering

    Science.gov (United States)

    Nelson, Austin; Rogachev, Grigory; Uberseder, Ethan; Hooker, Josh; Koshchiy, Yevgen

    2014-09-01

    Light exotic nuclei provide a unique opportunity to test the predictions of modern ab initio theoretical calculations near the drip line. In ab initio approaches, nuclear structure is described starting from bare nucleon-nucleon and three-nucleon interactions. Calculations are very heavy and can only be performed for the lightest nuclei (A objective of this project was to test the performance and perform position calibration of this proportional counter array. The test was done using 12C beam. The excitation function for 12C + p elastic scattering was measured and calibration of the proportional counter was performed using known resonances in 13N. The method of calibration, including solid angle calculations, normalization corrections, and position calibration will be presented. Light exotic nuclei provide a unique opportunity to test the predictions of modern ab initio theoretical calculations near the drip line. In ab initio approaches, nuclear structure is described starting from bare nucleon-nucleon and three-nucleon interactions. Calculations are very heavy and can only be performed for the lightest nuclei (A objective of this project was to test the performance and perform position calibration of this proportional counter array. The test was done using 12C beam. The excitation function for 12C + p elastic scattering was measured and calibration of the proportional counter was performed using known resonances in 13N. The method of calibration, including solid angle calculations, normalization corrections, and position calibration will be presented. Funded by DOE and NSF-REU Program; Grant No. PHY-1263281.

  2. Gamma rays from the 31P(n, γ)32P reaction

    NARCIS (Netherlands)

    Middelkoop, G. van

    1967-01-01

    The 31P(n, γ)32P reaction is studied with a 5 cm3 Ge(Li) counter. Altogether, 54 γ-rays are detected with experimental energy errors between 0.4 and 3.0 keV. The Q-value of the reaction is determined as Q = 7936.8±0.8 keV.

  3. Combinative application of pH-zone-refining and conventional high-speed counter-current chromatography for preparative separation of caged polyprenylated xanthones from gamboge.

    Science.gov (United States)

    Xu, Min; Fu, Wenwei; Zhang, Baojun; Tan, Hongsheng; Xiu, Yanfeng; Xu, Hongxi

    2016-02-01

    An efficient method for the preparative separation of four structurally similar caged xanthones from the crude extracts of gamboge was established, which involves the combination of pH-zone-refining counter-current chromatography and conventional high-speed counter-current chromatography for the first time. pH-zone-refining counter-current chromatography was performed with the solvent system composed of n-hexane/ethyl acetate/methanol/water (7:3:8:2, v/v/v/v), where 0.1% trifluoroacetic acid was added to the upper organic stationary phase as a retainer and 0.03% triethylamine was added to the aqueous mobile phase as an eluter. From 3.157 g of the crude extract, 1.134 g of gambogic acid, 180.5 mg of gambogenic acid and 572.9 mg of a mixture of two other caged polyprenylated xanthones were obtained. The mixture was further separated by conventional high-speed counter-current chromatography with a solvent system composed of n-hexane/ethyl acetate/methanol/water (5:5:10:5, v/v/v/v) and n-hexane/methyl tert-butyl ether/acetonitrile/water (8:2:6:4,v/v/v/v), yielding 11.6 mg of isogambogenic acid and 10.4 mg of β-morellic acid from 218.0 mg of the mixture, respectively. The purities of all four of the compounds were over 95%, as determined by high-performance liquid chromatography, and the chemical structures of the four compounds were confirmed by electrospray ionization mass spectrometry and NMR spectroscopy. The combinative application of pH-zone-refining counter-current chromatography and conventional high-speed counter-current chromatography shows great advantages in isolating and enriching the caged polyprenylated xanthones. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Fabrication and performance of the Pt-Ru/Ni-P/FTO counter electrode for dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Ma, Huanmei; Tian, Jianhua; Bai, Shuming; Liu, Xiaodong; Shan, Zhongqiang

    2014-01-01

    Highlights: • Pt-Ru alloy acts as the catalyst of counter electrodes in dye-sensitized solar cell. • Ni-P/FTO (fluorine-doped SnO 2 ) substrate is prepared by electroless plating method. • Pt-Ru/Ni-P/FTO counter electrode is fabricated by electrodeposition method. • The Ni-P sublayer improves the conductivity and light reflectance of FTO substrate. • The cell with Pt-Ru/Ni-P/FTO counter electrode exhibits an improved efficiency. - Abstract: In this paper, Pt-Ru/Ni-P/FTO has been designed and fabricated as the counter electrode for dye-sensitized solar cells. The Pt-Ru catalytic layer and Ni-P alloy sublayer are prepared by traditional electrodeposition method and a simple electroless plating method, respectively, and the preparation conditions have been optimized. The scanning electron microscopy (SEM) images show that the Pt-Ru particles are evenly distributed on FTO and Ni-P/FTO substrate. By X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS), it is confirmed that the Ni-P amorphous alloy has been formed, and no other compounds involved Ni and P have been formed. The electrochemical measurement results reveal that the Pt-Ru electrode has higher catalytic activity and stability towards tri-iodine reduction reaction than Pt electrode in the organic medium. The Ni-P sublayer deposited on FTO glasses increases the conductivity and light-reflection ability of the counter electrode, and this contributes to lowering the inner resistance of the cell and improving the light utilization efficiency. Through the photovoltaic test, it is confirmed that the energy conversion efficiency of a single DSSC with the optimized Pt-Ru/Ni-P/FTO counter electrode is increased by 29% compared with that of the cell based on the Pt/FTO counter electrode under the same conditions

  5. Cross sections and reaction rates for 23Na(p,n) 23Mg, 27Al(p,n) 27Si, 27Al(α,n) 30P, 29Si(α,n) 32S, and 30Si(α,n) 33S

    International Nuclear Information System (INIS)

    Flynn, D.S.; Sekharan, K.K.; Hiller, B.A.; Laumer, H.; Weil, J.L.; Gabbard, F.

    1978-01-01

    The total neutron production cross sections for the 23 Na(p,n) 23 Mg, 27 Al(p,n) 27 Si, 27 Al(α,n) 30 P, 29 Si(α,n) 32 S, and 30 Si(α,n) 33 S reactions have been measured for bombarding energies from threshold to 6.3 MeV. The neutron detector was a 60-cm diameter sphere of polyethylene with eight 10 BF 3 counters and was insensitive to the angle and energy of the emitted neutrons. Cross sections for inverse reactions have been obtained using the principle of detailed balance. The data have been used to determine parameters for statistical model calculations to facilitate extrapolation of cross sections to higher bombarding energies. These reactions are relevant to problems of nucleosynthesis and stellar evolution and to studies of radiation damage. Nucleosynthesis reaction rates, N/sub A/(sigmav), were determined for the reactions studied and are tabulated for temperatures ranging from 0.4 x 10 9 to 10.0 x 10 9 K

  6. Cerenkov counters at ISABELLE

    International Nuclear Information System (INIS)

    Etkin, A.; Kostoulas, I.; Leith, D.W.G.S.; Thun, R.

    1977-01-01

    The Cherenkov counter described for use at Isabelle is a threshold counter in which light is focussed on phototubes. The counter is applicable in large-angle, small-aperture magnetic spectrometers for measurement of particle yields at large p/sub T/. Three of these counters will provide complete π-K-p separation in the range of 7-20 GeV/c. Other Cherenkov counters are discussed and a bibliography of relevant literature on the counters utilizing photoionization is included

  7. Townsend coefficients of gases in avalanche counters

    International Nuclear Information System (INIS)

    Brunner, G.

    1978-01-01

    Though much work has been done by many authors in the last few years in the development and application of avalanche counters for ion radiation, it is based upon values of the Townsend coefficients as the essential gas parameter, which were determined many years ago for much lower reduced field strengths F/p than prevail in such counters. Therefore absolute determinations of α in vapours of methyl alcohol, cyclohexane, acetone, and n-heptene were performed under original conditions of avalanche counters. The values obtained do not differ by more than 30%-50% from the former values indeed, extrapolated over F/p for the first three mentioned substances, but the amounts of A and B in the usual representation α/p=A exp(-B(F/p)) are much greater for the stronger reduced fields. This is of importance for such counter properties as the dependence of pulse heights on pressure, voltage, electrode distance etc., which are governed by other combinations of A and B than α/p itself. A comparison of results for different ionic radiations shows a marked influence of the primary ionization density along the particle tracks which is hard to explain. (Auth.)

  8. Space and power efficient hybrid counters array

    Science.gov (United States)

    Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY

    2009-05-12

    A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.

  9. First Townsend coefficient of organic vapour in avalanche counters

    International Nuclear Information System (INIS)

    Sernicki, J.

    1990-01-01

    A new concept is presented in the paper for implementing the proven method of determining the first Townsend coefficient (α) of gases using an avalanche counter. The A and B gas constants, interrelated by the expression α/p=A exp[-B/(K/p)], are analyzed. Parallel-plate avalanche counters (PPAC) with an electrode spacing d from 0.1 to 0.4 cm have been employed for the investigation, arranged to register low-energy alpha particles at n-heptane vapour pressures of p≥5 Torr. An in-depth discussion is given, covering the veracity and the behaviour vs K/p, of the n-heptane A and B constants determined at reduced electric-field intensity values ranging from 173.5 to 940 V/cm Torr; the constants have been found to depend upon d. The results of the investigation are compared to available data of the α coefficient of organic vapours used in avalanche counters. The PPAC method of determining α reveals some imperfections at very low values of the pd product. (orig.)

  10. Counter terms for low momentum nucleon-nucleon interactions

    International Nuclear Information System (INIS)

    Holt, Jason D.; Kuo, T.T.S.; Brown, G.E.; Bogner, Scott K.

    2004-01-01

    There is much current interest in treating low energy nuclear physics using the renormalization group (RG) and effective field theory (EFT). Inspired by this RG-EFT approach, we study a low-momentum nucleon-nucleon (NN) interaction, V low-k , obtained by integrating out the fast modes down to the scale Λ∼2 fm -1 . Since NN experiments can only determine the effective interaction in this low momentum region, our chief purpose is to find such an interaction for complex nuclei whose typical momenta lie below this scale. In this paper we find that V low-k can be highly satisfactorily accounted for by the counter terms corresponding to a short range effective interaction. The coefficients C n of the power series expansion ΣC n q n for the counter terms have been accurately determined, and results derived from several meson-exchange NN interaction models are compared. The counter terms are found to be important only for the S, P and D partial waves. Scaling behavior of the counter terms is studied. Finally we discuss the use of these methods for computing shell model matrix elements

  11. Thermodynamics of micellization of cationic surfactants based on O-alkyl and O-perfluoro-N,N'-diisopropylisourea: Effect of the counter ion nature

    International Nuclear Information System (INIS)

    Lehanine, Zineb; Badache, Leila

    2011-01-01

    Graphical abstract: The pseudo phase thermodynamic model was applied to study the process of micellization of O-dodecyl- and O-tridecafluorooctyl-N,N'-diisopropylisourea hydrohalogenides. Free energy of micellization is weakly temperature dependent and decreased slightly with the size of the counterion, indicating a more favored micellization. Enthalpies and entropies of micellization decrease strongly with increasing temperature. The enthalpy-entropy compensation phenomenon was observed for all the surfactants studied. Highlights: → The pseudo phase thermodynamic model was applied to study the process of micellization of O-dodecyl- and O-tridecafluorooctyl-N,N'-diisopropylisourea hydrohalogenides. → Free energy of micellization is weakly temperature dependent and decreased slightly with the size of the counterion, indicating a more favored micellization. → Enthalpies and entropies of micellization decrease strongly with increasing temperature. → The enthalpy-entropy compensation phenomenon was observed for all the surfactants studied. - Abstract: A thermodynamic study on the micellization process of two series of cationic surfactants, viz. the O-dodecyl-N,N'-diisopropylisourea hydrochloride, hydrobromide, and hydroiodide and the O-tridecafluorooctyl-N,N'-diisopropylisourea hydrochloride, and hydrobromide, is reported. In order to explain the effect of the counter ion nature in the micellization process, thermodynamic parameters to include the standard free energy (ΔG mic 0 ), enthalpy (ΔH mic 0 ), entropy (ΔS mic 0 ), and heat capacity (ΔC p,mic 0 ) of micellization have been discussed. These parameters are evaluated from the variation of the critical micelle concentration (CMC) with temperature by fitting these values to expressions derived on the basis of a micellization thermodynamic model. The heat capacities of micellization (ΔC p,mic 0 ) were determined from the temperature dependence of ΔH mic 0 . For both surfactant series, the free energy of

  12. ISFET pH Sensitivity: Counter-Ions Play a Key Role.

    Science.gov (United States)

    Parizi, Kokab B; Xu, Xiaoqing; Pal, Ashish; Hu, Xiaolin; Wong, H S Philip

    2017-02-02

    The Field Effect sensors are broadly used for detecting various target analytes in chemical and biological solutions. We report the conditions under which the pH sensitivity of an Ion Sensitive Field Effect transistor (ISFET) sensor can be significantly enhanced. Our theory and simulations show that by using pH buffer solutions containing counter-ions that are beyond a specific size, the sensor shows significantly higher sensitivity which can exceed the Nernst limit. We validate the theory by measuring the pH response of an extended gate ISFET pH sensor. The consistency and reproducibility of the measurement results have been recorded in hysteresis free and stable operations. Different conditions have been tested to confirm the accuracy and validity of our experiment results such as using different solutions, various oxide dielectrics as the sensing layer and off-the-shelf versus IC fabricated transistors as the basis of the ISFET sensor.

  13. Contribution to the study of π- + p → π0 + n and π- + p → π0 + π + n reactions at the energies of the maxima of the π-nucleon interaction in the T = 1/2 state total cross section

    International Nuclear Information System (INIS)

    Turlay, R.

    1962-01-01

    In the first part of this experiment, we determined the total cross section for processes yielding only neutral particles, from 300 to 1600 MeV. For this, we counted the number of incident π - , as defined by a counter telescope, which interact in a liquid-hydrogen target without giving charged particles in a 4π counter surrounding the target. In the second part of this experiment, we have separated the reaction π - p → π 0 n and π - p → π 0 π 0 n between 300 and 1100 MeV, by supposing that only these two reactions was realized by placing lead absorbers between the target and 4π counter and by comparing the counting rate for neutral events with and without lead. The transmission thus measured is a function of the average number of photons produced and therefore of the ratio between the two neutral channels, π 0 n and π 0 π 0 n. In the last section of this work, we discuss the experimental results and compare them to those obtained by other authors in the study of photoproduction and the π-nucleon interaction. (author) [fr

  14. Preparative Separation of Six Rhynchophylla Alkaloids from Uncaria macrophylla Wall by pH-Zone Refining Counter-Current Chromatography

    OpenAIRE

    Zhang, Qinghai; Lin, Changhu; Duan, Wenjuan; Wang, Xiao; Luo, Aiqin

    2013-01-01

    pH-Zone refining counter-current chromatography was successfully applied to the preparative isolation and purification of six alkaloids from the ethanol extracts of Uncaria macrophylla Wall. Because of the low content of alkaloids (about 0.2%, w/w) in U. macrophylla Wall, the target compounds were enriched by pH-zone refining counter-current chromatography using a two-phase solvent system composed of petroleum ether–ethyl acetate–isopropanol–water (2:6:3:9, v/v), adding 10 mM triethylamine ...

  15. Preparation of a Counter Electrode with P-Type NiO and Its Applications in Dye-Sensitized Solar Cell

    Directory of Open Access Journals (Sweden)

    Chuen-Shii Chou

    2010-01-01

    Full Text Available This study investigates the applicability of a counter electrode with a P-type semiconductor oxide (such as NiO on a dye-sensitized solar cell (DSSC. The counter electrode is fabricated by depositing an NiO film on top of a Pt film, which has been deposited on a Fluorine-doped tin oxide (FTO glass using an ion-sputtering coater (or E-beam evaporator, using a simple spin coating method. This study also examines the effect of the average thickness of TiO2 film deposited on a working electrode upon the power conversion efficiency of a DSSC. This study shows that the power conversion efficiency of a DSSC with a Pt(E/NiO counter electrode (4.28% substantially exceeds that of a conventional DSSC with a Pt(E counter electrode (3.16% on which a Pt film was deposited using an E-beam evaporator. This result is attributed to the fact that the NiO film coated on the Pt(E counter electrode improves the electrocatalytic activity of the counter electrode.

  16. Angular Distributions of Neutrons from (p,n)-Reactions in some Mirror Nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Stroemberg, L G; Wiedling, T; Holmqvist, B

    1964-04-15

    The angular distributions of neutrons from the reactions {sup 13}C (p,n) {sup 13}N and {sup 19}F (p, n) {sup 19}Ne have been measured for some energies close to the reactions threshold. For the reaction {sup 9}B (p, n) {sup 9}C angular distributions have been measured at several proton energies below the reaction threshold of the neutrons to the first excited state in {sup 11}C . A 5.5 MeV Van de Graaff has been used for the experiments. The neutrons were detected with a long counter. The measurements were carried out for 16 energies for the B (p,n) reaction, 3 energies for the C (p, n) reaction, and for 7 energies for the F 19(p, n) reaction. One of the main reasons for investigating these (p, n) reactions was to check whether the direct reaction process is important at low proton energies as well as close to reaction thresholds in nuclei consisting of closed shells of neutrons and protons either with an extra nucleon outside the closed shell or a nucleon hole. Comparisons with a theory proposed by Bloom, Glendenning, and Moszkowski have been performed.

  17. Multi-level modelling of the response of the ultraminiature proportional counter: gas gain phenomena and pulse height spectra

    International Nuclear Information System (INIS)

    Olko, P.; Moutarde, C.; Segur, P.

    1995-01-01

    The ultraminiature proportional counters, UMC, unique radiation detectors for monitoring high intensity therapy fields, designed by Kliauga and operated at Columbia University (USA), have yielded a number of pulse height distributions for photons, neutrons and ions at simulated diameters of 5-50 nm. Monte Carlo calculations of the gas gain in such a counter questioned the possibility of achieving proportionally at such low simulated diameters. The response of the UMC has now been modelled taking into account both fluctuations of energy deposited in the counter volume and its calculated gas gain. Energy deposition was calculated using the MOCA-14, MOCA-8 and TRION codes, whereby distributions of ionisations d(j) after irradiations with 137 Cs, 15 MeV neutrons and 7 MeV.amu -1 deuterons were obtained. Monte Carlo calculations of electron avalanches in UMC show that the size of the single-electron avalanche P(n) reaching the anode depends strongly on the location of the primary ionisation within the counter volume. Distributions of the size of electron avalanches for higher numbers of primary ionisations, P *j (n), were obtained by successive convolutions of P(n). Finally, the counter response was obtained by weighting P *j (n) over d(j) distributions. On comparing the measured and calculated spectra it was concluded that the previously proposed single-electron peak calibration method might not be valid for the UMC due to the excessive width and overlap of electron avalanche distributions. Better agreement between the measured and calculated spectra is found if broader electron avalanche distributions than those used in the present calculations, are assumed. (author)

  18. Study of the reaction π-p → eta n in the region of the N*(1688)

    International Nuclear Information System (INIS)

    Chaffee, R.B.

    1975-01-01

    In an experiment performed at the Bevatron, a negative-pion beam incident on a 20-cm liquid-hydrogen target produced reactions of the form π/sup -/p → neutral final state. The final-state neutron was detected by plastic-scintillator counters. The final-state photons were detected by lead-plate spark chambers, which covered about 3.7 π solid angle, or by lead-scintillator sandwich counters, which covered most of the open face of the spark-chamber array. For this analysis, a kinematic fit was done on the L. B. L. computer for each event in which two photons were detected. For each momentum, events which fit the hypothesis π/sup -/p → eta n were binned according to the calculated production cosine, and the resulting distributions were corrected by comparing to the results of a Monte-Carlo calculation for the same reaction. The differential cross section was calculated for each bin, and the values for each momentum were fit to a sum of Legendre polynomials in production cosine. In the final chapter, the Legendre polynomial coefficients, the total cross section, and the differential cross sections extrapolated to 0 0 and 180 0 are compared to the results of other experiments, and some speculations are offered as to the spin-parity states which affect the measured behavior of the reaction. The conclusion is drawn that the N (1688) does not contribute, but that the N (1670) does, with a cross section of (0.84 +- 0.21) mb. (U.S.)

  19. Ideal response function of a 3He proportional counter to thermal neutrons determined by different length counters

    International Nuclear Information System (INIS)

    Takeda, Naoto; Kudo, Katsuhisa; Kobayashi, Katsuhei; Yoshimoto, Takaaki

    2000-01-01

    The relative gas multiplication along the cylindrical axis of three 3 He proportional counters with different length were measured by using a thermal neutron beam at the Kyoto University Reactor and an ideal response function by taking into account the difference of pulse height spectra were measured by different length counters. The three 3 He proportional counters (model type of P4-0806, P4-0806 and P4-0808 manufactured by Reuter-Stokes) prepared for relative gas multiplication measurements had identical structure having cylindrical outer shells of 304 stainless steel except for different sensitive lengths of 10 cm, 15 cm and 20 cm, respectively. All counters were filled with 400 kPa of 3 He gas and 200 kPa of Ar gas. The pulse height distributions were measured by moving the counter in the direction of it's cylindrical axis perpendicular to the thermal neutron beam. The measured pulse heights corresponding to the full energy peaks at various entrance points were normalized to that of the whole counter irradiation. The results as a function of the distance from the bottom edge of the stainless steel cylinder are shown. The total transition region of gas gain corresponded to about 23 %, 15 % and 10 % of each nominal sensitive region corresponding to shot, middle and long counters. The ideal pulse height spectrum (dots) obtained by using proportional counters of 10 cm and 20 cm in nominal sensitive length to thermal neutron beam is shown in the paper in comparison to simulated one which was calculated assuming the constant gain within the sensitive region and zero gas gain outside the sensitive regions. The simulation realized the ideal response function fairly well. (S.Y.)

  20. Small P Systems with Catalysts or Anti-Matter Simulating Generalized Register Machines and Generalized Counter Automata

    Directory of Open Access Journals (Sweden)

    Artiom Alhazov

    2015-11-01

    Full Text Available In this paper we focus on two weak forms of cooperation in P systems, namely, catalytic rules and matter/anti-matter annihilation rules. These variants of P systems both are computationally complete, while the corresponding rule complexity turns out to be of special interest. For establishing considerably small universal P systems in both cases, we found two suitable tools: generalized register machines and generalized counter automata. Depending on the features used in the different variants, we construct several small universal P systems.

  1. Evaluation of a low-cost optical particle counter (Alphasense OPC-N2) for ambient air monitoring

    Science.gov (United States)

    Crilley, Leigh R.; Shaw, Marvin; Pound, Ryan; Kramer, Louisa J.; Price, Robin; Young, Stuart; Lewis, Alastair C.; Pope, Francis D.

    2018-02-01

    A fast-growing area of research is the development of low-cost sensors for measuring air pollutants. The affordability and size of low-cost particle sensors makes them an attractive option for use in experiments requiring a number of instruments such as high-density spatial mapping. However, for these low-cost sensors to be useful for these types of studies their accuracy and precision need to be quantified. We evaluated the Alphasense OPC-N2, a promising low-cost miniature optical particle counter, for monitoring ambient airborne particles at typical urban background sites in the UK. The precision of the OPC-N2 was assessed by co-locating 14 instruments at a site to investigate the variation in measured concentrations. Comparison to two different reference optical particle counters as well as a TEOM-FDMS enabled the accuracy of the OPC-N2 to be evaluated. Comparison of the OPC-N2 to the reference optical instruments shows some limitations for measuring mass concentrations of PM1, PM2.5 and PM10. The OPC-N2 demonstrated a significant positive artefact in measured particle mass during times of high ambient RH (> 85 %) and a calibration factor was developed based upon κ-Köhler theory, using average bulk particle aerosol hygroscopicity. Application of this RH correction factor resulted in the OPC-N2 measurements being within 33 % of the TEOM-FDMS, comparable to the agreement between a reference optical particle counter and the TEOM-FDMS (20 %). Inter-unit precision for the 14 OPC-N2 sensors of 22 ± 13 % for PM10 mass concentrations was observed. Overall, the OPC-N2 was found to accurately measure ambient airborne particle mass concentration provided they are (i) correctly calibrated and (ii) corrected for ambient RH. The level of precision demonstrated between multiple OPC-N2s suggests that they would be suitable devices for applications where the spatial variability in particle concentration was to be determined.

  2. Preparative Separation of Six Rhynchophylla Alkaloids from Uncaria macrophylla Wall by pH-Zone Refining Counter-Current Chromatography

    Directory of Open Access Journals (Sweden)

    Qinghai Zhang

    2013-12-01

    Full Text Available pH-Zone refining counter-current chromatography was successfully applied to the preparative isolation and purification of six alkaloids from the ethanol extracts of Uncaria macrophylla Wall. Because of the low content of alkaloids (about 0.2%, w/w in U. macrophylla Wall, the target compounds were enriched by pH-zone refining counter-current chromatography using a two-phase solvent system composed of petroleum ether–ethyl acetate–isopropanol–water (2:6:3:9, v/v, adding 10 mM triethylamine in organic stationary phase and 5 mM hydrochloric acid in aqueous mobile phase. Then pH-zone refining counter-current chromatography using the other two-phase solvent system was used for final purification. Six target compounds were finally isolated and purified by following two-phase solvent system composed of methyl tert-butyl ether (MTBE–acetonitrile–water (4:0.5:5, v/v, adding triethylamine (TEA (10 mM to the organic phase and HCl (5 mM to aqueous mobile phase. The separation of 2.8 g enriched total alkaloids yielded 36 mg hirsutine, 48 mg hirsuteine, 82 mg uncarine C, 73 mg uncarine E, 163 mg rhynchophylline, and 149 mg corynoxeine, all with purities above 96% as verified by HPLC Their structures were identified by electrospray ionization-mass spectrometry (ESI-MS and 1H-NMR spectroscopy.

  3. Preparative separation of six rhynchophylla alkaloids from Uncaria macrophylla wall by pH-zone refining counter-current chromatography.

    Science.gov (United States)

    Zhang, Qinghai; Lin, Changhu; Duan, Wenjuan; Wang, Xiao; Luo, Aiqin

    2013-12-12

    pH-Zone refining counter-current chromatography was successfully applied to the preparative isolation and purification of six alkaloids from the ethanol extracts of Uncaria macrophylla Wall. Because of the low content of alkaloids (about 0.2%, w/w) in U. macrophylla Wall, the target compounds were enriched by pH-zone refining counter-current chromatography using a two-phase solvent system composed of petroleum ether-ethyl acetate-isopropanol-water (2:6:3:9, v/v), adding 10 mM triethylamine in organic stationary phase and 5 mM hydrochloric acid in aqueous mobile phase. Then pH-zone refining counter-current chromatography using the other two-phase solvent system was used for final purification. Six target compounds were finally isolated and purified by following two-phase solvent system composed of methyl tert-butyl ether (MTBE)-acetonitrile-water (4:0.5:5, v/v), adding triethylamine (TEA) (10 mM) to the organic phase and HCl (5 mM) to aqueous mobile phase. The separation of 2.8 g enriched total alkaloids yielded 36 mg hirsutine, 48 mg hirsuteine, 82 mg uncarine C, 73 mg uncarine E, 163 mg rhynchophylline, and 149 mg corynoxeine, all with purities above 96% as verified by HPLC Their structures were identified by electrospray ionization-mass spectrometry (ESI-MS) and 1H-NMR spectroscopy.

  4. Design of a novel quantum reversible ternary up-counter

    Science.gov (United States)

    Houshmand, Pouran; Haghparast, Majid

    2015-08-01

    Reversible logic has been recently considered as an interesting and important issue in designing combinational and sequential circuits. The combination of reversible logic and multi-valued logic can improve power dissipation, time and space utilization rate of designed circuits. Only few works have been reported about sequential reversible circuits and almost there are no paper exhibited about quantum ternary reversible counter. In this paper, first we designed 2-qutrit and 3-qutrit quantum reversible ternary up-counters using quantum ternary reversible T-flip-flop and quantum reversible ternary gates. Then we proposed generalized quantum reversible ternary n-qutrit up-counter. We also introduced a new approach for designing any type of n-qutrit ternary and reversible counter. According to the results, we can conclude that applying second approach quantum reversible ternary up-counter is better than the others.

  5. Needle counter

    International Nuclear Information System (INIS)

    Fujita, Yuzo

    1977-01-01

    Needle counter had been devised by Geiger about 60 years ago before the present GM counter appeared. It is suitable for the detection of weak radiation because it is limited in effective volume, if the background due to mainly cosmic ray is proportional to the effective volume of the counter. Recently the very low β detector having a needle counter as the main detector has been developed. It showed highly excellent performance in the measurements of small area samples, about ten times sensitive as compared with other detectors. The counter is installed in the very low radiation measuring well at Nokogiriyama, Chiba Prefecture, using a NaI scintillator as its guard counter. D. H. Wilkinson first treated a gas amplification counter theoretically and quantitatively. The authors have obtained good results in the comparison with the experiments of the counter using a generalized form of Wilkinson theory. The findings obtained through this study seem to be applicable to the electrode arrangement which is important for the counter design. It was found that the excellent rise time of induced pulses in a gas amplification counter was achieved in larger amplification factor and smaller convolution effect. In the detection of charged particles with small obstructing capability such as γ ray, faster rise time and higher pulses can be obtained with needle counters than wire counters. (Wakatsuki, Y.)

  6. A Compton Suppressed Gamma Ray Counter For Radio Assay of Materials

    Science.gov (United States)

    Godfrey, Benjamin

    2016-03-01

    Rare event searches, such as direct dark matter experiments, require materials with ultra-low levels of natural radioactivity. We present a neutron activation analysis (NAA) technique for assaying metals, specifically titanium used for cryostat construction. Earlier attempts at NAA encountered limitations due to bulk activation via (n, p) reactions, which contributed to large continuum backgrounds due to Compton tails. Our method involves a heavy water shielded exposure to minimize (n,p) reactions and a sodium iodide shielded high purity germanium counter for the gamma ray assay. Preliminary results on assays for U/Th/K contamination in titaniumwill be presented.

  7. Distributed performance counters

    Science.gov (United States)

    Davis, Kristan D; Evans, Kahn C; Gara, Alan; Satterfield, David L

    2013-11-26

    A plurality of first performance counter modules is coupled to a plurality of processing cores. The plurality of first performance counter modules is operable to collect performance data associated with the plurality of processing cores respectively. A plurality of second performance counter modules are coupled to a plurality of L2 cache units, and the plurality of second performance counter modules are operable to collect performance data associated with the plurality of L2 cache units respectively. A central performance counter module may be operable to coordinate counter data from the plurality of first performance counter modules and the plurality of second performance modules, the a central performance counter module, the plurality of first performance counter modules, and the plurality of second performance counter modules connected by a daisy chain connection.

  8. N-Doped graphene/PEDOT composite films as counter electrodes in DSSCs: Unveiling the mechanism of electrocatalytic activity enhancement

    Science.gov (United States)

    Paterakis, Georgios; Raptis, Dimitrios; Ploumistos, Alexandros; Belekoukia, Meltiani; Sygellou, Lamprini; Ramasamy, Madeshwaran Sekkarapatti; Lianos, Panagiotis; Tasis, Dimitrios

    2017-11-01

    A composite film was obtained by layer deposition of N-doped graphene and poly(3,4-ethylenedioxythiophene) (PEDOT) and was used as Pt-free counter electrode for dye-sensitized solar cells. N-doping of graphene was achieved by annealing mixtures of graphene oxide with urea. Various parameters concerning the treatment of graphene oxide-urea mixtures were monitored in order to optimize the electrocatalytic activity in the final solar cell device. These include the mass ratio of components, the annealing temperature, the starting concentration of the mixture in aqueous solution and the spinning rate for film formation. PEDOT was applied by electrodeposition. The homogeneity of PEDOT coverage onto either untreated or thermally annealed graphene oxide-urea film was assessed by imaging (AFM/SEM) and surface techniques (XPS). It was found that PEDOT was deposited in the form of island structures onto untreated graphene oxide-urea film. On the contrary, the annealed film was homogeneously covered by the polymer, acquiring morphology of decreased roughness. An apparent chemical interaction between PEDOT and N-doped graphene flakes was revealed by XPS data, involving potential grafting of PEDOT chains onto graphitic lattice through Csbnd C bonding. In addition, diffusion of nitrogen-containing fragments within the PEDOT layer was found to take place during electrodeposition process, resulting in enhanced interfacial interactions between components. The solar cell with the optimized N-doped graphene/PEDOT composite counter electrode exhibited a power conversion efficiency (η) of 7.1%, comparable within experimental error to that obtained by using a reference Pt counter electrode, which showed a value of 7.0%.

  9. A NRESPG Monte Carlo code for the calculation of neutron response functions for gas counters

    Energy Technology Data Exchange (ETDEWEB)

    Kudo, K; Takeda, N; Fukuda, A [Electrotechnical Lab., Tsukuba, Ibaraki (Japan); Torii, T; Hashimoto, M; Sugita, T; Yang, X; Dietze, G

    1996-07-01

    In this paper, we show the outline of the NRESPG and some typical results of the response functions and efficiencies of several kinds of gas counters. The cross section data for the several kinds of filled gases and the wall material of stainless steel or aluminum are taken mainly from ENDF/B-IV. The ENDF/B-V for stainless steel is also used to investigate the influence on pulse height spectra of gas counters due to the difference of nuclear data files. (J.P.N.)

  10. Excitation of accelerating plasma waves by counter-propagating laser beams

    International Nuclear Information System (INIS)

    Shvets, Gennady; Fisch, Nathaniel J.; Pukhov, Alexander

    2002-01-01

    The conventional approach to exciting high phase velocity waves in plasmas is to employ a laser pulse moving in the direction of the desired particle acceleration. Photon downshifting then causes momentum transfer to the plasma and wave excitation. Novel approaches to plasma wake excitation, colliding-beam accelerator (CBA), which involve photon exchange between the long and short counter-propagating laser beams, are described. Depending on the frequency detuning Δω between beams and duration τ L of the short pulse, there are two approaches to CBA. First approach assumes (τ L ≅2/ω p ). Photons exchanged between the beams deposit their recoil momentum in the plasma driving the plasma wake. Frequency detuning between the beams determines the direction of the photon exchange, thereby controlling the phase of the plasma wake. This phase control can be used for reversing the slippage of the accelerated particles with respect to the wake. A variation on the same theme, super-beatwave accelerator, is also described. In the second approach, a short pulse with τ L >>ω p -1 detuned by Δω∼2ω p from the counter-propagating beam is employed. While parametric excitation of plasma waves by the electromagnetic beatwave at 2ω p of two co-propagating lasers was first predicted by Rosenbluth and Liu [M. N. Rosenbluth and C. S. Liu, Phys. Rev. Lett. 29, 701 (1972)], it is demonstrated that the two excitation beams can be counter-propagating. The advantages of using this geometry (higher instability growth rate, insensitivity to plasma inhomogeneity) are explained, and supporting numerical simulations presented

  11. Gas-multiplication factor of a proportional counter operated at low temperature described with the Diethorn, Rose-Korff and townsend expressions

    Energy Technology Data Exchange (ETDEWEB)

    Fukumura, Kazuko; Nakanishi, Akio; Kobayashi, Takayuki [Shiga Univ. of Medical Science, Otsu (Japan)

    1996-07-01

    In the present work, the gas-multiplication factor is expressed with the Rose-Korff and Townsend methods as well as with the Diethorn method. A proportional counter with helium or neon works only at low temperature. This is discussed in terms of the number of electrons emitted when an ion is neutralized at the cathode of the counter. (J.P.N.)

  12. Calibration of a dePangher long counter from 2 keV to 19 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Slaughter, D R; Rueppel, D W [California Univ., Livermore (USA). Lawrence Livermore Lab.

    1977-09-01

    The authors have measured the sensitivity of a dePangher precision long counter (PLC) relative to /sup 7/Li(p,n), T(p,n), and T(d,n) differential cross sections over the neutron energy range 10 keV-19 MeV. Absolute sensitivity at 2 keV is also measured, using a scandium filtered beam at a reactor. Results obtained with errors in the range 5-30% are consistent with the assumption of a nearly constant sensitivity over the range 2 keV-6 MeV, but exhibit a reduction above 12 MeV.

  13. Geiger-Mueller haloid counter dead time dependence on counting rate

    International Nuclear Information System (INIS)

    Onishchenko, A.M.; Tsvetkov, A.A.

    1980-01-01

    The experimental dependences of the dead time of Geiger counters (SBM-19, SBM-20, SBM-21 and SGM-19) on the loading, are presented. The method of two sources has been used to determine the dead time counters of increased stability. The counters are switched on according to the usually used circuit of discrete counting with loading resistance of 50 MOhm and the separating capacity of 10 pF. Voltage pulses are given to the counting device with the time of resolution of 100 ns, discrimenation threshold 3 V, input resistance 3.6 Ω and the input capacity-15 pF. The time constant of the counter RC-circuit is 50 μs

  14. Investigations of X-ray response of single wire anode Ar-N2 flow type gas scintillation proportional counters

    International Nuclear Information System (INIS)

    Garg, S.P.; Sharma, R.C.

    1984-01-01

    The X-ray response of single wire anode gas scintillation proportional counters of two different geometries operated with argon+nitrogen gases in continuous flow has been investigated with wire anodes of diameters 25 μm to 1.7 mm. An energy resolution of 19% is obtained for 5.9 keV X-rays entering the counter perpendicular to the anode in pill-box geometry with 25 μm diameter anode. With cylindrical geometry counters energy obtained at 5.9 keV are 18%, 24% and 33% for 50 μm, 0.5 mm and 1.7 mm diameter anodes respectively. An analysis of the observed resolution shows that the contribution from photon counting statistics to the relative variance of scintillation pulses even for X-rays in Ar-N 2 single wire anode gas scintillation proportional counters is small and is not a limiting factor. The energy resolution with thicker anodes, where the contribution from the variance of the charge multiplication factor also has been minimised, is found to deteriorate mainly by the interaction in the scintillation production region. Comments are made on the possibility of improvement in energy resolution by suppression of pulses due to such interactions with the help of the pulse risetime discrimination technique. (orig.)

  15. People's practices : exploring contestation, counter-development, and rural livelihoods : ...cases from Muktinagar, Bangladesh

    NARCIS (Netherlands)

    Huq, H.

    2000-01-01

    <p>People's Practices: Exploring contestation, Counter - development, and rural livelihoodsp>>The central problems explored in the thesis concern the vulnerability of disadvantaged local people, especially women, and their agency; development discourses and counter-development

  16. Contribution to the study of {pi}{sup -} + p {yields} {pi}{sup 0} + n and {pi}{sup -} + p {yields} {pi}{sup 0} + {pi} + n reactions at the energies of the maxima of the {pi}-nucleon interaction in the T = 1/2 state total cross section; Contribution a l'etude des reactions {pi}{sup -} + p {yields} {pi}{sup 0} + n et {pi}{sup -} + p {yields} {pi}{sup 0} + n aux energies des maxima de la section efficace totale de l'interaction {pi}{sup -} nucleon dans l'etat de spin isobarique T = 1/2

    Energy Technology Data Exchange (ETDEWEB)

    Turlay, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    In the first part of this experiment, we determined the total cross section for processes yielding only neutral particles, from 300 to 1600 MeV. For this, we counted the number of incident {pi}{sup -}, as defined by a counter telescope, which interact in a liquid-hydrogen target without giving charged particles in a 4{pi} counter surrounding the target. In the second part of this experiment, we have separated the reaction {pi}{sup -} p {yields} {pi}{sup 0} n and {pi}{sup -} p {yields} {pi}{sup 0} {pi}{sup 0} n between 300 and 1100 MeV, by supposing that only these two reactions was realized by placing lead absorbers between the target and 4{pi} counter and by comparing the counting rate for neutral events with and without lead. The transmission thus measured is a function of the average number of photons produced and therefore of the ratio between the two neutral channels, {pi}{sup 0} n and {pi}{sup 0} {pi}{sup 0} n. In the last section of this work, we discuss the experimental results and compare them to those obtained by other authors in the study of photoproduction and the {pi}-nucleon interaction. (author) [French] Dans une premiere partie de cette experience, nous determinons la section efficace totale des processus ne donnant naissance qu'a des particules neutres de 300 et 1 600 MeV. Pour cela nous comptons le nombre de {pi}{sup -}, defini par un telescope incident, qui interagissent dans une cible d'hydrogene liquide sans donner de particules chargees dans un compteur 4{pi} entourant cette cible. Dans la deuxieme partie de l'experience nous avons separe les reactions {pi}{sup -} p {yields} {pi}{sup 0} n et {pi}{sup -} p {yields} {pi}{sup 0} {pi}{sup 0} n entre 300 et 1 600 MeV en supposant que seules ces deux voies soient importantes a ces energies. La separation de ces deux reactions a ete realisee en placant des ecrans de plomb entre la cible et le compteur 4 {pi}, et en comparant les traces de comptage des evenements a secondaires neutres avec et sans

  17. Counter of radiation in body parts

    International Nuclear Information System (INIS)

    Pollard, D.E.

    1983-01-01

    A new radiation counter for the determination of radiocontaminated body parts has been designed. Composed of several movable detectors, shielded from background radiation and focused on different parts of the human body by narrow apertures in the lead enclosure, the invention provides a quick tool for quantitative and qualitative part-by-part analysis of the body with respect to radiocontamination. The counter can be handled easily by the tested person himself and consequently, it is suitable for mass controls etc. (G.J.P.)

  18. Real-time aerosol photometer and optical particle counter comparison

    International Nuclear Information System (INIS)

    Santi, E.; Belosi, F.; Santachiara, G.; Prodi, F.; Berico, M.

    2010-01-01

    The paper presents the results of a comparison exercise among real-time aerosol samplers, based on different light scattering techniques. The comparison was carried out near to the ISAC institute in a box positioned inside the CNR research area in Bologna. Two nephelometers (Dust Trak from TSI, and Air Genius from Unitec) and an optical particle counter (ENVIRO-check from Grimm) were used for P M1 and P M10 fraction assessment. In the case of the optical particle counter, the particle number concentration in each size bin was also used. In parallel, two manual sampling lines were employed for reference (gravimetric) measurements. The results highlight different factor scales for the dust monitors, in comparison with gravimetric assessment, underlining the importance of a user calibration of such monitors as a function of the specific aerosol sampled. Moreover, the relative fluctuations of the hourly P M 10 and P M1 concentrations, against daily average concentrations, were studied in order to compare the ability of each sampler to follow changes in the aerosol size distribution. It was found that the photometers and optical particle counter revealed different behaviours. In the latter, a small increase in the particle concentration number in the coarse fraction gave a relatively high increase in the mass concentration that was not measured by the photometers. The explanation could be the relatively slight influence of a small particle number variation on the total scattered light for the photometers, unlike the case of the optical particle counter, where each particle contributes to the mass concentration. This aspect merits future research in order to better understand optical particle counter output used in P Mx monitoring activities.

  19. TiN nanoparticles on CNT-graphene hybrid support as noble-metal-free counter electrode for quantum-dot-sensitized solar cells.

    Science.gov (United States)

    Youn, Duck Hyun; Seol, Minsu; Kim, Jae Young; Jang, Ji-Wook; Choi, Youngwoo; Yong, Kijung; Lee, Jae Sung

    2013-02-01

    The development of an efficient noble-metal-free counter electrode is crucial for possible applications of quantum-dot-sensitized solar cells (QDSSCs). Herein, we present TiN nanoparticles on a carbon nanotube (CNT)-graphene hybrid support as a noble-metal-free counter electrode for QDSSCs employing a polysulfide electrolyte. The resulting TiN/CNT-graphene possesses an extremely high surface roughness, a good metal-support interaction, and less aggregation relative to unsupported TiN; it also has superior solar power conversion efficiency (4.13 %) when applying a metal mask, which is much higher than that of the state-of-the-art Au electrode (3.35 %). Based on electrochemical impedance spectroscopy measurements, the enhancement is ascribed to a synergistic effect between TiN nanoparticles and the CNT-graphene hybrid, the roles of which are to provide active sites for the reduction of polysulfide ions and electron pathways to TiN nanoparticles, respectively. The combination of graphene and CNTs leads to a favorable morphology that prevents stacking of graphene or bundling of CNTs, which maximizes the contact of the support with TiN nanoparticles and improves electron-transfer capability relative to either carbon material alone. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. n-p Short-Range Correlations from (p,2p+n) Measurements

    Science.gov (United States)

    Tang, A.; Watson, J. W.; Aclander, J.; Alster, J.; Asryan, G.; Averichev, Y.; Barton, D.; Baturin, V.; Bukhtoyarova, N.; Carroll, A.; Gushue, S.; Heppelmann, S.; Leksanov, A.; Makdisi, Y.; Malki, A.; Minina, E.; Navon, I.; Nicholson, H.; Ogawa, A.; Panebratsev, Yu.; Piasetzky, E.; Schetkovsky, A.; Shimanskiy, S.; Zhalov, D.

    2003-01-01

    We studied the 12C(p,2p+n) reaction at beam momenta of 5.9, 8.0, and 9.0 GeV/c. For quasielastic (p,2p) events pf, the momentum of the knocked-out proton before the reaction, was compared (event by event) with pn, the coincident neutron momentum. For |pn|>kF=0.220 GeV/c (the Fermi momentum) a strong back-to-back directional correlation between pf and pn was observed, indicative of short-range n-p correlations. From pn and pf we constructed the distributions of c.m. and relative motion in the longitudinal direction for correlated pairs. We also determined that 49±13% of events with |pf|>kF had directionally correlated neutrons with |pn|>kF.

  1. Facile synthesis of nitrogen-doped reduced graphene oxide as an efficient counter electrode for dye-sensitized solar cells

    Science.gov (United States)

    Wei, Liguo; Wang, Ping; Yang, Yulin; Luo, Ruidong; Li, Jinqi; Gu, Xiaohu; Zhan, Zhaoshun; Dong, Yongli; Song, Weina; Fan, Ruiqing

    2018-04-01

    A nitrogen-doped reduced graphene oxide (N-RGO) nanosheet was synthesized by a simple hydrothermal method and characterized by X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, and scanning electrode microscopy. After being deposited as counter electrode film for dye-sensitized solar cells (DSSCs), it is found that the synthesized N-RGO nanosheet has smaller charge-transfer resistance and better electrocatalytic activity towards reduction of triiodide than the reduced graphene oxide (RGO) nanosheet. Consequently, the DSSCs based on the N-RGO counter electrode achieve an energy conversion efficiency of 4.26%, which is higher than that of the RGO counter electrode (2.85%) prepared under the same conditions, and comparable to the value (5.21%) obtained with the Pt counter electrode as a reference. This N-RGO counter electrode offers the advantages of not only saving the cost of Pt itself but also simplifying the process of counter electrode preparation. Therefore, an inexpensive N-RGO nanosheet is a promising counter electrode material to replace noble metal Pt. [Figure not available: see fulltext.

  2. The Optimum Condition For Determination Of Radioactivity Of Pest Insects Labelled with P-32 By Using Liquid scintillation Counter

    International Nuclear Information System (INIS)

    Yarianto, S.; Susilo, Budi; Sutrisno, Singgih

    2002-01-01

    Tracer technique is needed in the control programe of pest insects especially for determining of its direction and dispersal. Radioisotopes of P-32 is frecuently used for labeling of pest insects. Liquid Scintillation Counter can be used effectively for measuring radioactivity of pest insects labelled by P-32. Optilnization of liquid compositions that consist of solvents. primary scintillation PPO and secondary scintillation POPOP were determined by examination of their compositions. Based on the research result obtained, composition of scintillator which had the highest efficiency. consists of P-Xylene solvent. primary scintillation PPO (5 g/l ) and secondary scintillation POPOP (0.5 g/l)

  3. Role of radial electric field in LH transition triggered by counter-NBI at low plasma density in the TUMAN-3M tokamak

    International Nuclear Information System (INIS)

    Tukachinsky, A.S.; Askinazi, L.G.; Chernyshev, F.V. and others; Krupnik, L.I.; Rushkevich, A.A.

    2008-01-01

    Threshold power needed to attain H-mode in a tokamak is a critical parameter for designing of future devices and in particular fusion reactor ITER [1]. According to commonly accepted scaling [2] the threshold power P t hr increases with average density n e when the density exceeds some n em in at which P t hr is minimal. An increase in the P t hr towards low density was observed in many experiments [3-6], prevents the transition at lower n e as well. Physics of the threshold power increase at low ne is not well understood. Since the radial electric field E r and E r xB sheared flow play important roles in the LH transition one could expect these quantities effect the low n-bar e transitions. Toroidal rotation and radial electric field generation during counter-NBI have been studied in [7] and recently reconsidered theoretically in [8]. Thus, motivation for the presented study is to analyze effect of counter-NBI on the LH transition at low density

  4. Multimode pulse counter

    International Nuclear Information System (INIS)

    Natanzon, D.D.

    1982-01-01

    A pulse counter with code conversion is described. The counter is based on the integrated circuits of direct-counting devices of medium integration. The counter ensures various modes of pulse counting depending on the logical control signals: reversible, two-channel summing, one-channel summing binary, summing with ''storage'' signal code fixation without interrupting pulse counting. Arrangement of the suggested structure as a microcircuit of medium integration might contribute to reduction in the counter type nomenclature in digital families of widely used integrated circuits

  5. Peculiarities of taking account of background and spectrometer response function in processing the (n,p) and (n,np) reaction spectra

    International Nuclear Information System (INIS)

    Aleksandrov, D.V.; Kovrigin, B.S.

    1980-01-01

    Problems of taking account of background and spectrometer response function when restoring spectra of the (n, p) and (n, np) reactions at 14 MeV neutron energy are considered. These reaction spectra have been obtained by the (E, ΔE) method by means of a telescope consisting of two proportional gas counters. Main components of the reaction background, which must be taken account of, are background due to irradiation with primary and scattered neutrons of telescope details, background of random coincidences and background from scattered neutrons. The following corrections are introduced to the apparatus spectrum obtained after subtraction of all the spectrum kinds: energy resolution correction for the spectrometer, apparatus line stub correction for the spectrometer, energy loss correction for gas filling the telescope, energy loss and particle absorption corrections for the target [ru

  6. A novel high-performance counter electrode for dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Wang Guiqiang; Lin Ruifeng; Lin Yuan; Li Xueping; Zhou Xiaowen; Xiao Xurui

    2005-01-01

    A novel Pt counter electrode for dye-sensitized solar cells (DSC) was prepared by thermal decomposition of H 2 PtCl 6 on NiP-plated glass substrate. The charge-transfer kinetic properties of the platinized NiP-plated glass electrode (Pt/NiP electrode) for triiodide reduction were studied by electrochemical impedance spectroscopy. Pt/NiP electrode has the advantage over the platinized FTO conducting glass electrode (Pt/FTO electrode) in increasing the light reflectance and reducing the sheet resistance leading to improve the light harvest efficiency and the fill factor of the dye-sensitized solar cells effectively. The photon-to-current efficiency and the overall conversion efficiency of DSC using Pt/NiP counter electrode is increased by 20% and 33%, respectively, compared to that of using Pt/FTO counter electrode. Examination of the anodic dissolution and the long-term test on the variation of charge-transfer resistance indicates the good stability of the Pt/NiP electrode in the electrolyte containing iodide/triiodide

  7. 78 FR 68854 - Over-the-Counter Ophthalmic Drug Products-Emergency Use Eyewash Products; Rescheduling of Public...

    Science.gov (United States)

    2013-11-15

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-1038... information on the formulation, manufacturing, and labeling of currently marketed over- the-counter (OTC... hearing will be held on March 7, 2014, from 9 a.m. to 5 p.m. Submit electronic or written requests to make...

  8. Calibration of the whole body counter at PSI

    International Nuclear Information System (INIS)

    Mayer, Sabine; Boschung, Markus; Fiechtner, Annette; Habegger, Ruedi; Meier, Kilian; Wernli, Christian

    2008-01-01

    At the Paul Scherrer Institut (PSI), measurements with the whole body counter are routinely carried out for occupationally exposed persons and occasionally for individuals of the population suspected of radioactive intake. In total about 400 measurements are performed per year. The whole body counter is based on a p-type high purity germanium (HPGe) coaxial detector mounted above a canvas chair in a shielded small room. The detector is used to detect the presence of radionuclides that emit photons with energies between 50 keV and 2 MeV. The room itself is made of iron from old railway rails to reduce the natural background radiation to 24 n Sv/h. The present paper describes the calibration of the system with the IGOR phantom. Different body sizes are realized by different standardized configurations of polyethylene bricks, in which small tubes of calibration sources can be introduced. The efficiency of the detector was determined for four phantom geometries (P1, P2, P4 and P6 simulating human bodies in sitting position of 12 kg, 24 kg, 70 kg and 110 kg, respectively. The measurements were performed serially using five different radionuclide sources ( 40 K, 60 Co, 133 Ba, 137 Cs, 152 Eu) within the phantom bricks. Based on results of the experiment, an efficiency curve for each configuration and the detection limits for relevant radionuclides were determined. For routine measurements, the efficiency curve obtained with the phantom geometry P4 was chosen. The detection limits range from 40 Bq to 1000 Bq for selected radionuclides applying a measurement time of 7 min. The proper calibration of the system, on one hand, is essential for the routine measurements at PSI. On the other hand, it serves as a benchmark for the already initiated characterisation of the system with Monte Carlo simulations. (author)

  9. 3D characterization of the forces in optical traps based on counter-propagation beams shaped by a spatial light modulator

    DEFF Research Database (Denmark)

    Kristensen, M. V.; Lindballe, T.; Kylling, A.

    2010-01-01

    An experimental characterization of the 3D forces, acting on a trapped polystyrene bead in a counter-propagating beam geometry, is reported. Using a single optical trap with a large working distance (in the BioPhotonics Workstation), we simultaneously measure the transverse and longitudinal...... trapping force constants. Two different methods were used: The Drag force method and the Equipartition method. We show that the counterpropagating beams traps are simple harmonic for small displacements. The force constants reveal a transverse asymmetry as - = 9.7 pN/µm and + = 11.3 pN/µm (at a total laser...... power of 2x35 mW) for displacements in opposite directions. The Equipartition method is limited by mechanical noise and is shown to be applicable only when the total laser power in a single 10 µm counter-propagating trap is below 2x20 mW....

  10. Hydrogen passivation of n+p and p+n heteroepitaxial InP solar cell structures

    Science.gov (United States)

    Chatterjee, B.; Ringel, S. A.; Hoffman, R., Jr.

    1995-01-01

    High-efficiency, heteroepitaxial (HE) InP solar cells, grown on GaAs, Si or Ge substrates, are desirable for their mechanically strong, light-weight and radiation-hard properties. However, dislocations, caused by lattice mismatch, currently limit the performance of the HE cells. This occurs through shunting paths across the active photovoltaic junction and by the formation of deep levels. In previous work we have demonstrated that plasma hydrogenation is an effective and stable means to passivate the electrical activity of dislocations in specially designed HE InP test structures. In this work, we present the first report of successful hydrogen passivation in actual InP cell structures grown on GaAs substrates by metalorganic chemical vapor deposition (MOCVD). We have found that a 2 hour exposure to a 13.56 MHz hydrogen plasma at 275 C reduces the deep level concentration in HE n+n InP cell structures from as-grown values of approximately 10(exp 15)/cm(exp -3), down to 1-2 x 10(exp 13)/cm(exp -3). The deep levels in the p-type base region of the cell structure match those of our earlier p-type test structures, which were attributed to dislocations or related point defect complexes. All dopants were successfully reactivated by a 400 C, 5 minute anneal with no detectable activation of deep levels. I-V analysis indicated a subsequent approximately 10 fold decrease in reverse leakage current at -1 volt reverse bias, and no change in the forward biased series resistance of the cell structure which indicates complete reactivation of the n+ emitter. Furthermore, electrochemical C-V profiling indicates greatly enhanced passivation depth, and hence hydrogen diffusion, for heteroepitaxial structures when compared with identically processed homoepitaxial n+p InP structures. An analysis of hydrogen diffusion in dislocated InP will be discussed, along with comparisons of passivation effectiveness for n+p versus p+n heteroepitaxial cell configurations. Preliminary hydrogen

  11. Micropipette as Coulter counter for submicron particles

    Science.gov (United States)

    Rudzevich, Yauheni; Ordonez, Tony; Evans, Grant; Chow, Lee

    2011-03-01

    Coulter counter based on micropipette has been around for several decades. Typical commercial Coulter counter has a pore size of 20 μ m, and is designed to detect micron-size blood cells. In recent years, there are a lot of interests in using nanometer pore size Coulter counter to detect single molecule and to sequence DNA. Here we describe a simple nanoparticle counter based on pulled micropipettes with a diameter of 50 -- 500 nm. Borosilicate micropipettes with an initial outer diameter of 1.00 mm and inner diameter of 0.5 mm are used. After pulling, the micropipettes are fire polished and ultrasound cleaned. Chlorinated Ag/AgCl electrodes and 0.1 M of KCl solution are used. The ionic currents are measured using an Axopatch 200B amplifier in the voltage-clamp mode. Several types and sizes of nanoparticles are measured, including plain silica and polystyrene nanospheres. The results will be discussed in terms of pH values of the solution and concentrations of the nanoparticles. Financial support from National Science Foundation (NSF-0901361) is acknowledged.

  12. Hydrogen Passivation of N(+)P and P(+)N Heteroepitaxial InP Solar Cell Structures

    Science.gov (United States)

    Chatterjee, B.; Davis, W. C.; Ringel, S. A.; Hoffman, R., Jr.

    1995-01-01

    Dislocations and related point defect complexes caused by lattice mismatch currently limit the performance of heteroepitaxial InP cells by introducing shunting paths across the active junction and by the formation of deep traps within the base region. We have previously demonstrated that plasma hydrogenation is an effective and stable means to passivate the electrical activity of such defects in specially designed heteroepitaxial InP test structures to probe hydrogen passivation at typical base depths within a cell structure. In this work, we present our results on the hydrogen passivation of actual heteroepitaxial n(+)p and p(+)n InP cell structures grown on GaAs substrates by metalorganic chemical vapor deposition (MOCVD). We have found that a 2 hour exposure to a 13.56 MHz hydrogen plasma at 275 C reduces the deep level concentration in the base regions of both n(+)p and p(+)n heteroepitaxial InP cell structures from as-grown values of 5 - 7 x 10(exp 14)/cc, down to 3 - 5 x 10(exp 12)/cc. All dopants were successfully reactivated by a 400 C, 5 minute anneal With no detectable activation of deep levels. I-V analysis indicated a subsequent approx. 100 fold decrease In reverse leakage current at -1 volt reverse bias, and an improved built in voltage for the p(+)n structures. ln addition to being passivated,dislocations are also shown to participate in secondary interactions during hydrogenation. We find that the presence of dislocations enhances hydrogen diffusion into the cell structure, and lowers the apparent dissociation energy of Zn-H complexes from 1.19 eV for homoepitaxial Zn-doped InP to 1.12 eV for heteroepitaxial Zn-doped InP. This is explained by additional hydrogen trapping at dislocations subsequent to the reactivation of Zn dopants after hydrogenation.

  13. Hydrogen passivation of N(+)-P and P(+)-N heteroepitaxial InP solar cell structures

    Science.gov (United States)

    Chatterjee, Basab; Davis, William C.; Ringel, Steve A.; Hoffman, Richard, Jr.

    1996-01-01

    Dislocations and related point defect complexes caused by lattice mismatch currently limit the performance of heteroepitaxial InP cells by introducing shunting paths across the active junction and by the formation of deep traps within the base region. We have previously demonstrated that plasma hydrogenation is an effective and stable means to passivate the electrical activity of such defects in specially designed heteroepitaxial InP test structures to probe hydrogen passivation at typical base depths within a cell structure. In this work, we present our results on the hydrogen passivation of actual heteroepitaxial n-p and p-n InP cell structures grown on GaAs substrates by metalorganic chemical vapor deposition (MOCVD). We have found that a 2 hour exposure to a 13.56 MHz hydrogen plasma at 275 C reduces the deep level concentration in the base regions of both n(+)-p and p(+)-n heteroepitaxial InP cell structures from as-grown values of 5-7 x 10(exp 14) cm(exp -3), down to 3-5 x 10(exp 12) cm(exp -3). All dopants were successfully reactivated by a 400 C, 5 minute anneal with no detectable activation of deep levels. One to five analysis indicated a subsequent approximately 100 fold decrease in reverse leakage current at -1 volt reverse bias, and an improved built in voltage for the p(+)-n structures. In addition to being passivated, dislocations are also shown to participate in secondary interactions during hydrogenation. We find that the presence of dislocations enhances hydrogen diffusion into the cell structure, and lowers the apparent dissociation energy of Zn-H complexes from 1.19 eV for homoepitaxial Zn-doped InP to 1.12 eV for heteroepitaxial Zn-doped InP. This is explained by additional hydrogen trapping at dislocations subsequent to the reactivation of Zn dopants after hydrogenation.

  14. P N Shukla

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Earth System Science. P N Shukla. Articles written in Journal of Earth System Science. Volume 110 Issue 2 June 2001 pp 103-110. High Iridium concentration of alkaline rocks of Deccan and implications to K/T boundary · P N Shukla N Bhandari Anirban Das A D Shukla J S Ray · More Details ...

  15. Quasifree (p ,p N ) scattering of light neutron-rich nuclei near N =14

    Science.gov (United States)

    Díaz Fernández, P.; Alvarez-Pol, H.; Crespo, R.; Cravo, E.; Atar, L.; Deltuva, A.; Aumann, T.; Avdeichikov, V.; Beceiro-Novo, S.; Bemmerer, D.; Benlliure, J.; Bertulani, C. A.; Boillos, J. M.; Boretzky, K.; Borge, M. J. G.; Caamaño, M.; Cabanelas, P.; Caesar, C.; Casarejos, E.; Catford, W.; Cederkäll, J.; Chartier, M.; Chulkov, L. V.; Cortina-Gil, D.; Datta Pramanik, U.; Dillmann, I.; Elekes, Z.; Enders, J.; Ershova, O.; Estradé, A.; Farinon, F.; Fernández-Domínguez, B.; Fraile, L. M.; Freer, M.; Galaviz, D.; Geissel, H.; Gernhäuser, R.; Golubev, P.; Göbel, K.; Hagdahl, J.; Heftrich, T.; Heil, M.; Heine, M.; Heinz, A.; Henriques, A.; Holl, M.; Hufnagel, A.; Ignatov, A.; Johansson, H. T.; Jonson, B.; Jurčiukonis, D.; Kalantar-Nayestanaki, N.; Kanungo, R.; Kelic-Heil, A.; Knyazev, A.; Kröll, T.; Kurz, N.; Labiche, M.; Langer, C.; Le Bleis, T.; Lemmon, R.; Lindberg, S.; Machado, J.; Marganiec, J.; Moro, A. M.; Movsesyan, A.; Nacher, E.; Najafi, A.; Nikolskii, E.; Nilsson, T.; Nociforo, C.; Panin, V.; Paschalis, S.; Perea, A.; Petri, M.; Pietras, B.; Pietri, S.; Plag, R.; Reifarth, R.; Ribeiro, G.; Rigollet, C.; Rossi, D.; Röder, M.; Savran, D.; Scheit, H.; Simon, H.; Sorlin, O.; Syndikus, I.; Taylor, J. T.; Tengblad, O.; Thies, R.; Togano, Y.; Vandebrouck, M.; Velho, P.; Volkov, V.; Wagner, A.; Wamers, F.; Weick, H.; Wheldon, C.; Wilson, G.; Winfield, J. S.; Woods, P.; Yakorev, D.; Zhukov, M.; Zilges, A.; Zuber, K.; R3B Collaboration

    2018-02-01

    Background: For many years, quasifree scattering reactions in direct kinematics have been extensively used to study the structure of stable nuclei, demonstrating the potential of this approach. The R 3B collaboration has performed a pilot experiment to study quasifree scattering reactions in inverse kinematics for a stable 12C beam. The results from that experiment constitute the first quasifree scattering results in inverse and complete kinematics. This technique has lately been extended to exotic beams to investigate the evolution of shell structure, which has attracted much interest due to changes in shell structure if the number of protons or neutrons is varied. Purpose: In this work we investigate for the first time the quasifree scattering reactions (p ,p n ) and (p ,2 p ) simultaneously for the same projectile in inverse and complete kinematics for radioactive beams with the aim to study the evolution of single-particle properties from N =14 to N =15 . Method: The structure of the projectiles 23O, 22O, and 21N has been studied simultaneously via (p ,p n ) and (p ,2 p ) quasifree knockout reactions in complete inverse kinematics, allowing the investigation of proton and neutron structure at the same time. The experimental data were collected at the R3B -LAND setup at GSI at beam energies of around 400 MeV/u. Two key observables have been studied to shed light on the structure of those nuclei: the inclusive cross sections and the corresponding momentum distributions. Conclusions: The knockout reactions (p ,p n ) and (p ,2 p ) with radioactive beams in inverse kinematics have provided important and complementary information for the study of shell evolution and structure. For the (p ,p n ) channels, indications of a change in the structure of these nuclei moving from N =14 to N =15 have been observed, i.e., from the 0 d5 /2 shell to the 1 s1 /2 . This supports previous observations of a subshell closure at N =14 for neutron-rich oxygen isotopes and its weakening

  16. Monolithic Active Pixel Matrix with Binary Counters ASIC with nested wells

    International Nuclear Information System (INIS)

    Fahim, F; Deptuch, G; Holm, S; Shenai, A; Lipton, R

    2013-01-01

    Monolithic Active Matrix with Binary Counters (MAMBO) V ASIC has been designed for detecting and measuring low energy X-rays. A nested well structure with a buried n-well (BNW) and a deeper buried p-well (BPW) is used to electrically isolate the detector from the electronics. BNW acts as an AC ground to electrical signals and behaves as a shield. BPW allows for a homogenous electric field in the entire detector volume. The ASIC consists of a matrix of 50 × 52 pixels, each of 105x105μm 2 . Each pixel contains analog functionality accomplished by a charge preamplifier, CR-RC 2 shaper and a baseline restorer. It also contains a window comparator with Upper and Lower thresholds which can be individually trimmed by 4 bit DACs to remove systematic offsets. The hits are registered by a 12 bit counter which is reconfigured as a shift register to serially output the data from the entire ASIC.

  17. Prototype fast neutron counter for the assay of impure plutonium

    International Nuclear Information System (INIS)

    Wachter, J.R.; Adams, E.L.; Ensslin, N.

    1987-01-01

    A fast coincident neutron counter using liquid scintillators and gamma-ray/neutron pulse-shape discrimination has been constructed for the analysis of plutonium samples with unknown self-multiplication and (α,n) production. The counter was used to measure plutonium-bearing materials that cover a range of masses and (α,n) reaction rates of importance to the safeguards community. Measured values of the 240 Pu effective mass differed, on average, from their declared values by 0.4% for plutonium oxides and by -2.2% for metal and MgO-loaded samples. Poorer results were obtained for materials with large (α,n) reaction rates and low self-multiplication such as plutonium ash and plutonium fluoride

  18. DEVELOPMENT OF HETEROGENEOUS PROPORTIONAL COUNTERS FOR NEUTRON DOSIMETRY.

    Science.gov (United States)

    Forouzan, Faezeh; Waker, Anthony J

    2018-01-10

    The use of a custom-made cylindrical graphite proportional counter (Cy-GPC) along with a cylindrical tissue equivalent proportional counter (TEPC) for neutron-gamma mixed-field dosimetry has been studied in the following steps: first, the consistency of the gamma dose measurement between the Cy-TEPC and the Cy-GPC was investigated over a range of 20 keV (X-ray) to 0.661 MeV (Cs-137 gamma ray). Then, with both the counters used simultaneously, the neutron and gamma ray doses produced by a P385 Neutron Generator (Thermo Fisher Scientific) together with a Cs-137 gamma source were determined. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Test of long scintillating counter prototypes for CDF-II

    International Nuclear Information System (INIS)

    Budagov, Yu.; Chirikov-Zorin, I.; Pukhov, O.; Incagli, M.; Leone, S.; Menzione, A.; Pauletta, G.; Tokar, S.

    2000-01-01

    New type long (up to 3 m) scintillating counter prototypes, developed for CDF-II, have been tested. The shift-spectrum fiber ribbons were used for light collection, and modern ultra compact photomultipliers R5600 were used for light detection. The efficiency for m.i.p. was excellent for all prototypes. The light yield from the far end of the counters was found to be more than 20 photoelectrons

  20. Technology Trends in Small Unmanned Aircraft Systems (sUAS) and Counter-UAS: A Five Year Outlook

    Science.gov (United States)

    2017-11-01

    I N S T I T U T E F O R D E F E N S E ANALYSES Technology Trends in Small Unmanned Aircraft Systems (sUAS) and Counter-UAS: A Five-Year Outlook...the copyright license under the clause at DFARS 252.227-7013 (a)(16) [June 2013]. INSTITUTE FOR DEFENSE ANALYSES IDA Paper P-8823 Technology Trends...threats to infrastructure posed across all domains—air, land, sea, and cyber. Although threats and technologies are rapidly evolving across all

  1. Development of a Neutron Long Counter Detector for (α, n) Cross Section Measurements at Ohio University

    Science.gov (United States)

    Brandenburg, Kristyn; Meisel, Zach; Brune, Carl R.; Massey, Thomas; Soltesz, Doug; Subedi, Shiv

    2017-01-01

    The origin of the elements from roughly zinc-to-tin (30 determined. The neutron-rich neutrino driven wind of core collapse supernova (CCSN) is a proposed site for the nucleosynthesis of these elements. However, a significant source of uncertainty exists in elemental abundance yields from astrophysics model calculations due to the uncertainty for (α , n) reaction rates, as most of the relevant cross sections have yet to be measured. We are developing a neutron long counter tailored to measure neutrons for (α , n) reaction measurements performed at The Ohio University Edwards Accelerator Laboratory. The detector design will be optimized using the Monte-Carlo N-Particle transport code (MCNP6). Details of the optimization process, as well as the present status of the detector design will be provided. The plans for first (α , n) cross section measurements will also be briefly discussed. This work was supported in part by the US Department of Energy under Grant Number DE-FG02-88ER40387.

  2. Silica aerogel Cherenkov counter for the KEK B-factory experiment

    CERN Document Server

    Sumiyoshi, T; Enomoto, R; Iijima, T; Suda, R; Leonidopoulos, C; Marlow, D R; Prebys, E; Kawabata, R; Kawai, H; Ooba, T; Nanao, M; Suzuki, K; Ogawa, S; Murakami, A; Khan, M H R

    1999-01-01

    Low-refractive-index silica aerogel is a convenient radiator for threshold-type Cherenkov counters, which are used for particle identification in high-energy physics experiments. For the BELLE detector at the KEK B-Factory we have produced about 2 m sup 3 of hydrophobic silica aerogels of n=1.01-1.03 using a new production method. The particle identification capability of the aerogel Cherenkov counters was tested and 3 sigma pion/proton separation has been achieved at 3.5 GeV/c. Radiation hardness of the aerogels was confirmed up to 9.8 Mrad. The Aerogel Cherenkov counter system (ACC) was successfully installed in the BELLE just before this conference.

  3. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women

    Science.gov (United States)

    Leicht, Carola; Gocłowska, Małgorzata A.; Van Breen, Jolien A.; de Lemus, Soledad; Randsley de Moura, Georgina

    2017-01-01

    Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1) counter-stereotype salience and (2) feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women (N = 208) attended to gender stereotypic (vs. counter-stereotypic) content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes) significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations. PMID:28626437

  4. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women.

    Science.gov (United States)

    Leicht, Carola; Gocłowska, Małgorzata A; Van Breen, Jolien A; de Lemus, Soledad; Randsley de Moura, Georgina

    2017-01-01

    Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1) counter-stereotype salience and (2) feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women ( N = 208) attended to gender stereotypic (vs. counter-stereotypic) content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes) significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations.

  5. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women

    Directory of Open Access Journals (Sweden)

    Carola Leicht

    2017-06-01

    Full Text Available Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1 counter-stereotype salience and (2 feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women (N = 208 attended to gender stereotypic (vs. counter-stereotypic content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations.

  6. Cerenkov counters at the Omega Facility

    CERN Multimedia

    1975-01-01

    P. Petroff on the left. Here one sees both the gas Cerenkov counters sitting in front of the magnet to select forward emitted particles. The smaller one, working at high pressure, sits nearest to the Omega magnet (see photo 7505073X), the other (see photo 7505071X) works at atmospheric pressure.

  7. Comparison of Nanostring nCounter® Data on FFPE Colon Cancer Samples and Affymetrix Microarray Data on Matched Frozen Tissues.

    Directory of Open Access Journals (Sweden)

    Xi Chen

    Full Text Available The prognosis of colorectal cancer (CRC stage II and III patients remains a challenge due to the difficulties of finding robust biomarkers suitable for testing clinical samples. The majority of published gene signatures of CRC have been generated on fresh frozen colorectal tissues. Because collection of frozen tissue is not practical for routine surgical pathology practice, a clinical test that improves prognostic capabilities beyond standard pathological staging of colon cancer will need to be designed for formalin-fixed paraffin-embedded (FFPE tissues. The NanoString nCounter® platform is a gene expression analysis tool developed for use with FFPE-derived samples. We designed a custom nCounter® codeset based on elements from multiple published fresh frozen tissue microarray-based prognostic gene signatures for colon cancer, and we used this platform to systematically compare gene expression data from FFPE with matched microarray array data from frozen tissues. Our results show moderate correlation of gene expression between two platforms and discovery of a small subset of genes as candidate biomarkers for colon cancer prognosis that are detectable and quantifiable in FFPE tissue sections.

  8. The orotate transporter oroP from Lactococcus lactis can be used both as a very efficient, food-grade selection and counter-selection marker for strain construction in many different organisms

    DEFF Research Database (Denmark)

    Defoor, Els Marie Celine; Martinussen, Jan

    frame oroP on pDBORO necessary for the uptake of orotate was identified. A number of industrial important strains like Lactococcus lactis, Bacillus subtilus, and Bacillus licheniformis have been shown to be unable to metabolize orotate. If the oroP gene was introduced into these strains they acquired...... the ability to utilize orotate. If the strains had a pyrimidine requirement, the oroP gene could function as a selectable marker when growing in the presence of orotate as sole pyrimidine source. In an otherwise resistant strain, oroP was shown to sensitize the strain towards the analog 5-Fluoroorotate....... It was shown that strains who have lost the oroP gene could easily be selected in the presence of 5-Fluoroorotate, thus being an efficient counter-selection marker. pyrimidine-requiring strain (pyr B, C or D) orotate negative Counter-selection marker: wild-type strain! Fluoro-orotate resistant Functional...

  9. A low-level needle counter

    International Nuclear Information System (INIS)

    Fujita, Y.; Taguchi, Y.; Imamura, M.; Inoue, T.; Tanaka, S.

    1977-01-01

    A small end-window type gas-flow counter which has a sharpened needle (anode) against the end-window plane (cathode) was developed for low-level counting of β particles to the amount of less than one count per hour in solid sources of relatively high specific activity. The advantage of the needle counter for low-level work is that being of a conical shape the active volume as against the window area is small. The background count rate of 0.0092+-0.0005 cpm was obtained for a 10 mm dia needle counter operating in GM mode and in anticoincidence with a well-type NaI(Tl) guard crystal with massive shields. The counter design and the counter characteristics are presented in detail. The needle counter is simple in design, low-cost and stable in long time operation. (author)

  10. Design of an extended range long counter using super Monte Carlo simulation

    International Nuclear Information System (INIS)

    Mazunga, Mohamed; Li, Taosheng; Li, Yanan; Hong, Bing; Wang, Yongfeng; Ji, Xiang

    2017-01-01

    We have designed an extended range neutron long counter on the basis of work optimized using SuperMC code. The problem of the existing traditional long counters is that their response function falls rapidly above 5 MeV. We proposed a new designed by adding two layers of converter material inside the polyethylene moderator. The relatively low density chromium and high density lead metals convert high energy neutron by (n, xn) spallation reaction. This produces more neutrons of lower energies, which have higher probability of being detected by thermal 3 He-counter. The response function at lower neutron energies was improved by inserting small polyethylene cylinder in front of 3 He counter. In this design we achieved to extent the flat response function of the long counter from few keV up to 150 MeV. The total fluctuation of response curve is less than ±9% over the entire energy range. The designed long counter is suitable to be used as neutron monitor for monitoring neutron fluence at high-energy neutron source. (authors)

  11. On the effect of N-GaN/P-GaN/N-GaN/P-GaN/N-GaN built-in junctions in the n-GaN layer for InGaN/GaN light-emitting diodes.

    Science.gov (United States)

    Kyaw, Zabu; Zhang, Zi-Hui; Liu, Wei; Tan, Swee Tiam; Ju, Zhen Gang; Zhang, Xue Liang; Ji, Yun; Hasanov, Namig; Zhu, Binbin; Lu, Shunpeng; Zhang, Yiping; Sun, Xiao Wei; Demir, Hilmi Volkan

    2014-01-13

    N-GaN/P-GaN/N-GaN/P-GaN/N-GaN (NPNPN-GaN) junctions embedded between the n-GaN region and multiple quantum wells (MQWs) are systematically studied both experimentally and theoretically to increase the performance of InGaN/GaN light emitting diodes (LEDs) in this work. In the proposed architecture, each thin P-GaN layer sandwiched in the NPNPN-GaN structure is completely depleted due to the built-in electric field in the NPNPN-GaN junctions, and the ionized acceptors in these P-GaN layers serve as the energy barriers for electrons from the n-GaN region, resulting in a reduced electron over flow and enhanced the current spreading horizontally in the n- GaN region. These lead to increased optical output power and external quantum efficiency (EQE) from the proposed device.

  12. Phenomenological study of the p p →π+p n reaction

    Science.gov (United States)

    Fäldt, G.; Wilkin, C.

    2018-02-01

    Fully constrained bubble chamber data on the p p →π+p n and p p →π+d reactions are used to investigate the ratio of the counting rates for the two processes as function of the p n excitation energy Q . Though it is important to include effects associated with the p -wave nature of pion production, the data are insufficient to establish unambiguously the dependence on Q . The angular distributions show the presence of higher partial waves which seem to be anomalously large at small Q . The dispersion relation method to determine scattering lengths is extended to encompass cases where, as for the p p →π+p n reaction, there is a bound state and, in a test example, it is shown that the values deduced for the low-energy neutron-proton scattering parameters are significantly influenced by the pion p -wave behavior.

  13. Nuclear accident dosimetry: the calibration of Geiger-Mueller and 2π proportional counters for sulphur and gold

    International Nuclear Information System (INIS)

    Delafield, H.J.; Reading, A.H.

    1981-10-01

    A reference, 2π precision counter was set up at Harwell and absolutely calibrated for the measurement of sulphur discs ( 32 P) and gold foils ( 198 Au) used in the UK personnel criticality dosimeter. Sample sulphur discs and gold foils were irradiated in the GLEEP reactor at Harwell, counted in the 2π counter, and their activities absolutely assayed by the National Physical Laboratory. The 2π counter was then used to intercalibrate the GM counters used routinely for the assessment of the criticality dosimeter. The mean measured efficiencies of the GM counters were found to be for 32 P in sulphur discs within +- 4%, and for gold ( 198 Au) within +- 6% of the values given by previous calibrations. (author)

  14. Proceedings of the symposium on measurements of neutron energy spectra using recoil proton proportional counters

    International Nuclear Information System (INIS)

    Urabe, Itsumasa

    1986-01-01

    This is a report of the symposium on measurements of neutron energy spectra using recoil proton proportional counters held at the Research Reactor Institute of Kyoto University on January 27 in 1986. An energy resolution, wall effects of response functions, n · γ discrimination methods and other fundamental properties of recoil proton counters are discussed for a new development of an application of this counter. (author)

  15. 300-MHz optical discriminator-counter

    International Nuclear Information System (INIS)

    Turko, B.; Lo, C.C.

    1981-07-01

    The prediction of future CO 2 content in the atmosphere is not completely credible because the oceanographers and terrestrial ecologists do not agree on the global CO 2 balance. Very precise measurements of O 2 /N 2 ratio using Raman scattering over a few years' period could provide important information and lead to the explanation of the disparity in the atmospheric CO 2 balance. An optical discriminator-counter has been developed to count closely spaced optical events in the few photon level. Simulated optical events as close as 2.5 ns apart had been positively detected by using selected photomultipliers and optimized discriminators. Testing of the optical discriminator-counter was done by using an electrical pulse pair spaced 3 ns apart and also by a similar optical pulse pair generated by fast light-emitting diode. The photomultiplier is capable of counting an average single photoelectron pulse frequency of 50 MHz and has a sensitive detecting area of 50 mm in diameter. The discriminator performance is discussed

  16. Proportional counter system for radiation measurement

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, M; Okudera, S

    1970-11-21

    A gas such as Xe or Kr employed in counter tubes is charged into the counter tube of a gas-flow type proportional counter for radiation measurement and into a vessel having a volume larger than that of the counter tube. The vessel communicates with the counter tube to circulate the gas via a pump through both the vessel and tube during measurement. An organic film such as a polyester synthetic resin film is used for the window of the counter tube to measure X-rays in the long wavelength range. Accordingly, a wide range of X-rays can be measured including both long and short wavelengths ranges by utilizing only one counter tube, thus permitting the gases employed to be effectively used.

  17. R N P Choudhary

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. R N P Choudhary. Articles written in Bulletin of Materials Science. Volume 23 Issue 4 August 2000 pp 239-241 Phase Transitions. Phase transitions in Na2TeO4 ceramics · N K Singh R N P Choudhary · More Details Abstract Fulltext PDF. Polycrystalline samples of NaTeO4 ...

  18. The Aluminum-Free P-n-P InGaAsN Double Heterojunction Bipolar Transistors

    Energy Technology Data Exchange (ETDEWEB)

    CHANG,PING-CHIH; LI,N.Y.; BACA,ALBERT G.; MONIER,C.; LAROCHE,J.R.; HOU,H.Q.; REN,F.; PEARTON,S.J.

    2000-08-01

    The authors have demonstrated an aluminum-free P-n-P GaAs/InGaAsN/GaAs double heterojunction bipolar transistor (DHBT). The device has a low turn-on voltage (V{sub ON}) that is 0.27 V lower than in a comparable P-n-p AlGaAs/GaAs HBT. The device shows near-ideal D. C. characteristics with a current gain ({beta}) greater than 45. The high-speed performance of the device are comparable to a similar P-n-p AlGaAs/GaAs HBT, with f{sub T} and f{sub MAX} values of 12 GHz and 10 GHz, respectively. This device is very suitable for low-power complementary HBT circuit applications, while the aluminum-free emitter structure eliminates issues typically associated with AlGaAs.

  19. Counter-discourse in Zimbabwean literature

    NARCIS (Netherlands)

    Mangena, Tendai

    2015-01-01

    Counter-Discourse in Zimbabwean Literature is a study of specific aspects of counter-discursive Zimbabwean narratives in English. In discussing the selected texts, my thesis is based on Terdiman’s (1989) the postcolonial concept of counter-discourse. In Zimbabwean literature challenges to a dominant

  20. Absolute measurements with a 4 {pi}-counter

    Energy Technology Data Exchange (ETDEWEB)

    Martinsson, Kerstin

    1959-06-15

    Measurements on standardized p-emitters have been made in a 4 it proportional flow-counter. The counter efficiency is found to be near 100 %. Absorption curves have been determined with plastic foils and aluminium. A comparison is made between the self-absorption arising in different methods of source preparation which include precipitates and the use of wetting agents The most reliable results have been obtained with sources on aluminium foils, where the foil absorption is calculated from the absorption curves and the self-absorption is supposed to be negligible for isotopes with end point energy above 0.5 MeV. The {beta}-emitters studied have energies ranging from 1.71 MeV ({sup 32}P) to 0.167 MeV ({sup 35}S). Most of them have been obtained from National Physical Laboratory and Atomic Energy Research Establishment, Harwell, England. The agreement between their calibration and our measurements is very good except in the case of Co 60.

  1. Absolute measurements with a 4 π-counter

    International Nuclear Information System (INIS)

    Martinsson, Kerstin

    1959-06-01

    Measurements on standardized p-emitters have been made in a 4 it proportional flow-counter. The counter efficiency is found to be near 100 %. Absorption curves have been determined with plastic foils and aluminium. A comparison is made between the self-absorption arising in different methods of source preparation which include precipitates and the use of wetting agents The most reliable results have been obtained with sources on aluminium foils, where the foil absorption is calculated from the absorption curves and the self-absorption is supposed to be negligible for isotopes with end point energy above 0.5 MeV. The β-emitters studied have energies ranging from 1.71 MeV ( 32 P) to 0.167 MeV ( 35 S). Most of them have been obtained from National Physical Laboratory and Atomic Energy Research Establishment, Harwell, England. The agreement between their calibration and our measurements is very good except in the case of Co 60

  2. Improving the performance of X-ray proportional counters by using field transistor preamplifiers

    International Nuclear Information System (INIS)

    Kalinina, N.I.; Mel'ttser, L.V.; Pan'kin, V.V.

    1972-01-01

    The possibility of using low-noise field-effect transistors with the n-channel in preamplifiers for x-ray proportional counters constitutes the object of this article. The operation of the preamplifier assembled according to the scheme of the voltage amplifier and charge-sensitive preamplifier has been studied. The use of the field-effect transistor with the n-channel in preamplifiers for proportional counters allows to improve significantly the energy resolution and operation at reduced voltage and at high loads. Notably good results have been obtained when constructing the circuit of the premplifier with the field-effect transistor on the charge-sensitive principle. The use of home-produced field-effect transistors makes it possible to construct detectors of roentgen radiometric instruments to measure light element content with proportional counters at reduced voltage

  3. Engineered porous silicon counter electrodes for high efficiency dye-sensitized solar cells.

    Science.gov (United States)

    Erwin, William R; Oakes, Landon; Chatterjee, Shahana; Zarick, Holly F; Pint, Cary L; Bardhan, Rizia

    2014-06-25

    In this work, we demonstrate for the first time, the use of porous silicon (P-Si) as counter electrodes in dye-sensitized solar cells (DSSCs) with efficiencies (5.38%) comparable to that achieved with platinum counter electrodes (5.80%). To activate the P-Si for triiodide reduction, few layer carbon passivation is utilized to enable electrochemical stability of the silicon surface. Our results suggest porous silicon as a promising sustainable and manufacturable alternative to rare metals for electrochemical solar cells, following appropriate surface modification.

  4. What is Counter-Enlightenment?

    OpenAIRE

    Darrin M. McMahon

    2017-01-01

    This article counters recent suggestions that there was no such thing as a “Counter-Enlightenment” or “Counter-Enlightenments,” and that such terms ought thus to be abandoned.   While acknowledging inevitable difficulties with the terms, the article argues that there can be no doubting the reality.   European countries faced a variety of vehement and self-conscious movements that defined themselves precisely through their opposition to what they took to be the corrosive effects of the Enlight...

  5. A portable neutron coincidence counter

    Energy Technology Data Exchange (ETDEWEB)

    Peurrung, A.J.; Bowyer, S.M.; Craig, R.A.; Dudder, G.B.; Knopf, M.A.; Panisko, M.E.; Reeder, P.L.; Stromswold, D.C.; Sunberg, D.S.

    1996-11-01

    Pacific Northwest National Laboratory has designed and constructed a prototype portable neutron coincidence counter intended for use in a variety of applications, such as the verification and inspection of weapons components, safety measurements for novel and challenging situations, portable portal deployment to prevent the transportation of fissile materials, uranium enrichment measurements in hard-to-reach locations, waste assays for objects that cannot be measured by existing measurement systems, and decontamination and decommissioning. The counting system weighs less than 40 kg and is composed of parts each weighing no more than 5 kg. In addition, the counter`s design is sufficiently flexible to allow rapid, reliable assembly around containers of nearly arbitrary size and shape. The counter is able to discern the presence of 1 kg of weapons-grade plutonium within an ALR-8 (30-gal drum) in roughly 100 seconds and 10 g in roughly 1000 seconds. The counter`s electronics are also designed for maximum adaptability, allowing operation under a wide variety of circumstances, including exposure to gamma-ray fields of 1 R/h. This report provides a detailed review of the design and construction process. Finally, preliminary experimental measurements that confirm the performance capabilities of this counter are discussed. 6 refs., 18 figs., 3 tabs.

  6. TiN-conductive carbon black composite as counter electrode for dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Li, G.R.; Wang, F.; Song, J.; Xiong, F.Y.; Gao, X.P.

    2012-01-01

    Highlights: ► The TiN nanoparticles are highly dispersed on conductive carbon black matrix (CCB). ► The well dispersion of TiN nanoparticles can improve electrochemical performance. ► The TiN/CCB shows a high photovoltaic performance with high conversion efficiency. - Abstract: TiN-conductive carbon black (CCB)/Ti electrodes are prepared by the nitridation of TiO 2 –CCB mixtures filmed on metallic Ti substrate in ammonia atmosphere. It is demonstrated from X-ray diffraction (XRD) and scanning electron microscopy (SEM) that TiN nanoparticles are highly dispersed on the CCB matrix in the composites. TiN–CCB/Ti electrodes show outstanding electrochemical performances as compared to individual TiN/Ti and CCB/Ti electrodes. In particular, the dye-sensitized solar cell (DSSC) using TiN–CCB (1:1, mass ratio)/Ti electrode presents an energy conversion efficiency of 7.92%, which is higher than that (6.59%) of the device using Pt/FTO (fluorine doped tin oxide) electrode measured under the same test conditions. Based on the analysis of cyclic voltammetry (CV) and electrochemical impedance spectra (EIS), the enhancements for the electrochemical and photochemical performance of TiN–CCB/Ti electrodes are attributed to the fact that the dispersed TiN nanoparticles in the CCB matrix provide an improved electrocatalytic activity and a facilitated diffusion for triiodine ions. This work shows a facile approach to develop metal nitrides–carbon composites as counter electrodes for DSSCs. High energy conversion efficiency and low lost will make the composites have significant potential for replacing the conventional Pt/FTO electrodes in DSSCs.

  7. CEDAR counter (internal part)

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    Here on the mounting bench. The counter is a differential Cerenkov, corrected for chromaticity, able to differentiate pions from kaons up to 350 GeV. Counters of this type were used in all SPS hadron beams.

  8. Whole Body Counters (rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Woodburn, John H. [Walter Johnson High School, Rockville, MD; Lengemann, Frederick W. [Cornell University

    1967-01-01

    Whole body counters are radiation detecting and measuring instruments that provide information about the human body. This booklet describes different whole body counters, scientific principles that are applied to their design, and ways they are used.

  9. Search for heavy pentaquark exotic baryons with hidden strangeness in the reactions p + N → (pφ) + N and p + N → [Λ(1520)K+] + N at Ep = 70 GeV

    International Nuclear Information System (INIS)

    Balatz, M.Ya.; Belyaev, I.M.; Dorofeev, V.A.

    1993-01-01

    In the experiments at the SPHINX facility on the 70 GeV proton beam of the IHEP accelerator a wide program of studying of the baryon diffractive production and search for exotic baryons in these processes is being carried out. The first data for the reactions p + N → (K + K - p) + N, p + N → (pφ) + N and p + N → [Λ(1520)K + ] + N are presented. The very sensitive upper limits for the cross sections for diffractive production of heavy narrow cryptoexotic baryon resonances with hidden strangeness in the mass region up to 4.5 GeV are obtained. 14 refs., 12 figs., 2 tabs

  10. Detection of neutrons of intermediate energy using 10B, enclosed in a coaxial Ge(Li) counter

    International Nuclear Information System (INIS)

    Huck, A.; Klotz, G.; Walter, G.

    1976-01-01

    A neutron detector operating in the energy range 1keV to roughly 1MeV with a time response that is fast enough to be used in time-of-flight experiments, has been designed and built. The neutron is absorbed in boron-10, placed inside a coaxial Ge(Li) counter. Efficient detection of the 478keV line from 7 Li, resulting from 10 B(n,α) 7 Li*, is realized. At the same time, the measurement of accompanying γ radiations, emitted by the neutron source, can be performed. Examples of results, obtained using (p,nγ) reactions, are given [fr

  11. Diversity of shrub tree layer, leaf litter decomposition and N release in a Brazilian Cerrado under N, P and N plus P additions

    International Nuclear Information System (INIS)

    Khan Baiocchi Jacobson, Tamiel; Cunha Bustamante, Mercedes Maria da; Rodrigues Kozovits, Alessandra

    2011-01-01

    This study investigated changes in diversity of shrub-tree layer, leaf decomposition rates, nutrient release and soil NO fluxes of a Brazilian savanna (cerrado sensu stricto) under N, P and N plus P additions. Simultaneous addition of N and P affected density, dominance, richness and diversity patterns more significantly than addition of N or P separately. Leaf litter decomposition rates increased in P and NP plots but did not differ in N plots in comparison to control plots. N addition increased N mass loss, while the combined addition of N and P resulted in an immobilization of N in leaf litter. Soil NO emissions were also higher when N was applied without P. The results indicate that if the availability of P is not increased proportionally to the availability of N, the losses of N are intensified. - Highlights: → Simultaneous addition of N and P affected richness and diversity of the shrub-tree layer of a Brazilian savanna more significantly than addition of N or P separately. → Leaf litter decomposition rates increased in P and NP plots but did not differ in N plots in comparison to control plots. N addition increased N mass loss, while the combined addition of N and P resulted in an immobilization of N in leaf litter. Soil NO emissions were also higher when N was applied without P. → The results indicated that if increases in N deposition in Cerrado ecosystems are not accompanied by P additions, higher N losses through leaching and gas emissions can occur with other ecosystem impacts. - Shrub-tree diversity and functioning of Brazilian savanna are affected by increasing nutrient availability.

  12. Diversity of shrub tree layer, leaf litter decomposition and N release in a Brazilian Cerrado under N, P and N plus P additions

    Energy Technology Data Exchange (ETDEWEB)

    Khan Baiocchi Jacobson, Tamiel, E-mail: tamiel@unb.br [Departamento de Ecologia, Universidade de Brasilia, Brasilia-DF 70919-970 (Brazil); Cunha Bustamante, Mercedes Maria da, E-mail: mercedes@unb.br [Departamento de Ecologia, Universidade de Brasilia, Brasilia-DF 70919-970 (Brazil); Rodrigues Kozovits, Alessandra, E-mail: kozovits@icep.ufop.br [Departamento de Ecologia, Universidade de Brasilia, Brasilia-DF 70919-970 (Brazil)

    2011-10-15

    This study investigated changes in diversity of shrub-tree layer, leaf decomposition rates, nutrient release and soil NO fluxes of a Brazilian savanna (cerrado sensu stricto) under N, P and N plus P additions. Simultaneous addition of N and P affected density, dominance, richness and diversity patterns more significantly than addition of N or P separately. Leaf litter decomposition rates increased in P and NP plots but did not differ in N plots in comparison to control plots. N addition increased N mass loss, while the combined addition of N and P resulted in an immobilization of N in leaf litter. Soil NO emissions were also higher when N was applied without P. The results indicate that if the availability of P is not increased proportionally to the availability of N, the losses of N are intensified. - Highlights: > Simultaneous addition of N and P affected richness and diversity of the shrub-tree layer of a Brazilian savanna more significantly than addition of N or P separately. > Leaf litter decomposition rates increased in P and NP plots but did not differ in N plots in comparison to control plots. N addition increased N mass loss, while the combined addition of N and P resulted in an immobilization of N in leaf litter. Soil NO emissions were also higher when N was applied without P. > The results indicated that if increases in N deposition in Cerrado ecosystems are not accompanied by P additions, higher N losses through leaching and gas emissions can occur with other ecosystem impacts. - Shrub-tree diversity and functioning of Brazilian savanna are affected by increasing nutrient availability.

  13. P-n junction diodes with polarization induced p-type graded InxGa1-xN layer

    Science.gov (United States)

    Enatsu, Yuuki; Gupta, Chirag; Keller, Stacia; Nakamura, Shuji; Mishra, Umesh K.

    2017-10-01

    In this study, p-n junction diodes with polarization induced p-type layer are demonstrated on Ga polar (0001) bulk GaN substrates. A quasi-p-type region is obtained by linearly grading the indium composition in un-doped InxGa1-xN layers from 0% to 5%, taking advantage of the piezoelectric and spontaneous polarization fields which exist in group III-nitride heterostructures grown in the typical (0001) or c-direction. The un-doped graded InxGa1-xN layers needed to be capped with a thin Mg-doped InxGa1-xN layer to make good ohmic contacts and to reduce the on-resistance of the p-n diodes. The Pol-p-n junction diodes exhibited similar characteristics compared to reference samples with traditional p-GaN:Mg layers. A rise in breakdown voltage from 30 to 110 V was observed when the thickness of the graded InGaN layer was increased from 100 to 600 nm at the same grade composition.

  14. Over-the-Counter Medicines

    Science.gov (United States)

    Over-the-counter (OTC) medicines are drugs you can buy without a prescription. Some OTC medicines relieve aches, pains and itches. ... medicine is safe enough to sell over-the-counter. Taking OTC medicines still has risks. Some interact ...

  15. Conducting polymers based counter electrodes for dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Veerender, P., E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Saxena, Vibha, E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Gusain, Abhay, E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Jha, P., E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Koiry, S. P., E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Chauhan, A. K., E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Aswal, D. K., E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com; Gupta, S. K., E-mail: veeru1009@gmail.com, E-mail: veeru1009@gmail.com [Technical Physics Division, Bhabha Atomic Research Centre, Mumbai - 400085 (India)

    2014-04-24

    Conducting polymer films were synthesized and employed as an alternative to expensive platinum counter electrodes for dye-sensitized solar cells. poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) thin films were spin-coated and polypyrrole films were electrochemically deposited via cyclic voltammetry method on ITO substrates. The morphology of the films were imaged by SEM and AFM. These films show good catalytic activity towards triiodide reduction as compared to Pt/FTO electrodes. Finally the photovoltaic performance of DSSC fabricated using N3 dye were compared with PT/FTO, PEDOT/ITO, and e-PPy counter electrodes.

  16. In-vivo radiation counter

    International Nuclear Information System (INIS)

    Pollard, D.E.

    1983-01-01

    This patent specification describes a radiation counter utilizing at least one detector for sensing radiation from a living body. The radiation counter also includes an aperture for forming a corridor between the body and the detector. A shield outside the corridor prevents passage of background radiation through the corridor and gaining access to the detector. The counter also includes a device for isolating a selected portion of the body from the corridor such that radiation counting is restricted to a region of the body through a separate detector. The corridor formation permits a user to stand in an upright position while the detector and detectors are able to separately monitor different sections of the body. The radiation counter overcomes the problem of obtaining accurate and quick measurements or radiation doses sustained by a large group of persons. (author)

  17. Comportamento da pressão arterial após exercícios contra-resistência: uma revisão sistemática sobre variáveis determinantes e possíveis mecanismos Comportamiento de la presión arterial después de ejercicios contra resistencia: una revisión sistemática sobre variables determinantes y posibles mecanismos Blood pressure behavior after counter-resistance exercises: a systematic review on determining variables and possible mechanisms

    Directory of Open Access Journals (Sweden)

    Marcos Doederlein Polito

    2006-12-01

    clinical relevance, despite its doubtful aspects concerning the variables that may contribute to its manifestation. The questioning is even greater when counter-exercise is applied with the purpose to cause PEH. Within this context, the aim of this study was to review some variables of the counter-resistance exercise that may be associated with PEH. Moreover, some physiological mechanisms possibly related to this effect were discussed. Fourteen references were found concerning counter-exercise and PEH. Six studies observed hypotensive effect for systolic blood pressure (SBP and/or diastolic blood pressure (DBP after the counter-resistance exercise. However, it was observed that some studies did not identify significant differences (p > 0.05 for SBP and DBP (n = 4 or even reported significant increase (p < 0.05 (SBP or DBP (n = 4. These disagreeing results may be related to the exercise volume and intensity, as well as the monitoring period. Nevertheless, it is possible to identify PEH when the counter-resistance exercise is applied, both in normotensive and hypertensive individuals. Despite of that, the physiological mechanisms responsible for this kind of response still remain obscure.

  18. CELULE FOTOVOLTAICE CU HETEROJONCŢIUNEA nCdS-pInP

    Directory of Open Access Journals (Sweden)

    Vasile BOTNARIUC

    2015-12-01

    Full Text Available Au fost studiate proprietăţile electrice şi fotoelectrice ale heterojoncţiunilor nCdS-pInP cu şi fără strat epitaxial inter-mediar poInP. S-a stabilit că la polarizări directe în mecanismul de transport al curentului predomină procesele de recom-binare în regiunea de sarcină spaţială. La polarizări inverse predomină procesele de tunelare. Prezenţa stratului epitaxial poInP depus repetat măreşte ISC până la 28,2 mA·cm-2, UCD până la 0,780 V, iar eficienţa conversiei energiei până la 15% la 300 K şi iluminare 100 mW/cm2. Fotosensibilitatea CF nCdS-poInP-pInP corespunde intervalului λ=550...950 nm cu un maximum plat localizat în intervalul λ=700...850 nm.HETEROJONCTION nCdS–pInP FOTOVOLTAIC CELLSElectrical and photoelectrical properties of nCdS-pInP hetero-junctions with and without intermediate poInP epitaxial layer were studied. It was established that the current flow mechanism at direct biases is determined mainly by the recombi-nation processes in the space charge region of the junction. At the reverse biases the tunneling processes are predominant. The presence of poInP layer leads to the photo-electrical parameters enhancing of hetero-junction: short circuit current increases up to 28,2 mA·cm -2, open circuit voltage up to 0,780V and the efficiency of solar energy conversion up to 15 % (at 300 K and illumination of 100mw/cm2. The photo-sensitivity of nCdS- poInP -pInP is in the wavelength region of λ= 550-950nm with a maximum localized to λ=700-850nm.

  19. Annealed n-vector p spin model

    International Nuclear Information System (INIS)

    Taucher, T.; Frankel, N.E.

    1992-01-01

    A disordered n-vector model with p spin interactions is introduced and studied in mean field theory for the annealed case. The complete solutions for the cases n = 2 and n = 3, is presented and explicit order parameter equations is given for all the stable solutions for arbitrary n. For all n and p was found on stable high temperature phase and one stable low temperature phase. The phase transition is of first order. For n = 2, it is continuous in the order parameters for p ≤ 4 and has a jump discontinuity in the order parameters if p > 4. For n = 3, it has a jump discontinuity in the order parameters for all p. 11 refs., 4 figs

  20. Counter support for WA35

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    This assembly was equipped with 78 counters, each consisting of a lucite cone, to produce Cerenkov light, and a CsI scintillator plate of 3 mm thickness glued on the face of the cone. The experiment WA35 was set-up in the s1 beam (West Hall) by the Darmstadt-Heidelberg-Virginia-Warsaw Collaboration to measure angular distributions and multiplicities of pions and recoil protons produced by hadrons interacting in nuclei. (See Annual Report 1976 p. 39)

  1. Ionic magnetic fluids in polar solvents with tuned counter-ions

    Energy Technology Data Exchange (ETDEWEB)

    Lopes Filomeno, C. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Grupo de Fluidos Complexos Inst. de Quimica, Univ. de Brasília, Brasília (DF) (Brazil); Kouyaté, M. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Cousin, F. [Lab. Léon Brillouin – CE-Saclay, Gif-sur-Yvette (France); Demouchy, G. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Dpt de physique, Univ. de Cergy Pontoise, Cergy-Pontoise (France); Dubois, E.; Michot, L.; Mériguet, G. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Perzynski, R., E-mail: regine.perzynski@upmc.fr [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Peyre, V.; Sirieix-Plénet, J. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Tourinho, F.A. [Grupo de Fluidos Complexos Inst. de Quimica, Univ. de Brasília, Brasília (DF) (Brazil)

    2017-06-01

    The aim of the present study is to propose a new reproducible method for preparing colloidal dispersions of electrostatically charged nanoparticles (NPs) in polar solvents with different kinds of counter-ions. Maghemite NPs are here dispersed in solvents of different dielectric constant, namely water, dimethylsulfoxide (DMSO) and an ionic liquid, ethylammonium nitrate (EAN). If the existence of a NP superficial charge happens to be necessary for the colloidal stability of the dispersions in these three solvents, the standard DLVO theory cannot be used any more to describe the colloidal stability in EAN. The structure of the dispersions and the strength of the interparticle repulsion are investigated by small angle X-ray scattering measurements, in association with Ludwig–Soret coefficient determinations. Specificities, associated to the nature of the counter-ions are identified in this work on the colloidal stability, on the interparticle repulsion and on the Ludwig–Soret coefficient. - Highlights: • A controlled synthesis of ionic magnetic fluids in three polar solvents is proposed. • Colloidal repulsion in the magnetic fluids depends on the counter-ion nature. • Soret coefficient of citrate-coated maghemite nanoparticles is probed in water-pH7. • Thermophilicity of nanoparticles depends on the nature of their counter-ions. • Nanoparticles dressed with same counter-ions have solvent-dependent thermoproperties.

  2. A Neutron Rem Counter

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Braun, J

    1964-01-15

    A neutron detector is described which measures the neutron dose rate in rem/h independently of the energy of the neutrons from thermal to 15 MeV. The detector consists of a BF{sub 3} proportional counter surrounded by a shield made of polyethylene and boron plastic that gives the appropriate amount of moderation and absorption to the impinging neutrons to obtain rem response. Two different versions have been developed. One model can utilize standard BF{sub 3} counters and is suitable for use in installed monitors around reactors and accelerators and the other model is specially designed for use in a portable survey instrument. The neutron rem counter for portable instruments has a sensitivity of 2.4 cps/mrem/h and is essentially nondirectional in response. With correct bias setting the counter is insensitive to gamma exposure up to 200 r/h from Co-60.

  3. Electronic transmission through p-n and n-p-n junctions of graphene

    Energy Technology Data Exchange (ETDEWEB)

    Setare, M R [Department of Science of Bijar, University of Kurdistan, Bijar (Iran, Islamic Republic of); Jahani, D, E-mail: rezakord@ipm.co, E-mail: Dariush110@gmail.co [Department of Physics, Razi University, Kermanshah (Iran, Islamic Republic of)

    2010-06-23

    In this paper, we first evaluate the electronic transmission of Dirac fermions into a p-n junction of gapped graphene and show that the final result depends on the sign of the refractive index, n. We also, by considering the appropriate wavefunctions in the region of the electrostatic potential, show that both transmission and the reflection probability turn out to be positive and less than unity instead of the negative transmission and higher than unity reflection coefficient commonly referred to as the Klein paradox. We then obtain the transmission probability corresponding to a special p-n junction for which there exists a region in which the low energy excitations of graphene acquire a finite mass and, interestingly, find that in this case the transmission is independent of the index of refraction, in contrast with the corresponding result for gapped graphene. We then discuss the validity of the solutions reported in some of the papers cited in this work which, considering the Buettiker formula, turn out to lead to the wrong results for conductivity.

  4. Benchmarking theoretical formalisms for (p ,p n ) reactions: The 15C(p ,p n )14C case

    Science.gov (United States)

    Yoshida, K.; Gómez-Ramos, M.; Ogata, K.; Moro, A. M.

    2018-02-01

    Background: Proton-induced knockout reactions of the form (p ,p N ) have experienced a renewed interest in recent years due to the possibility of performing these measurements with rare isotopes, using inverse kinematics. Several theoretical models are being used for the interpretation of these new data, such as the distorted-wave impulse approximation (DWIA), the transition amplitude formulation of the Faddeev equations due to Alt, Grassberger, and Sandhas (FAGS) and, more recently, a coupled-channels method here referred to as transfer-to-the- continuum (TC). Purpose: Our goal is to compare the momentum distributions calculated with the DWIA and TC models for the same reactions, using whenever possible the same inputs (e.g., distorting potential). A comparison with already published results for the FAGS formalism is performed as well. Method: We choose the 15C(p ,p n )14C reaction at an incident energy of 420 MeV/u, which has been previously studied with the FAGS formalism. The knocked-out neutron is assumed to be in a 2 s single-particle orbital. Longitudinal and transverse momentum distributions are calculated for different assumed separation energies. Results: For all cases considered, we find a very good agreement between DWIA and TC results. The energy dependence of the distorting optical potentials is found to affect in a modest way the shape and magnitude of the momentum distributions. Moreover, when relativistic kinematics corrections are omitted, our calculations reproduce remarkably well the FAGS result. Conclusions: The results found in this work provide confidence on the consistency and accuracy of the DWIA and TC models for analyzing momentum distributions for (p ,p n ) reactions at intermediate energies.

  5. Effects of electron and proton irradiations on n/p and p/n GaAs cells grown by MOCVD

    International Nuclear Information System (INIS)

    Weinberg, I.; Swartz, C.K.; Hart, R.E. Jr.

    1987-01-01

    State-of-the-art n/p and p/n heteroface GaAs cells, processed by metal organic chemical vapor deposition, were irradiated by 1 MeV electrons and 37 MeV protons and their performance determined as a function of fluence. It was found that the p/n cells were more radiation resistant than the n/p cells. The increased loss in the n/p cells was attributed to increases in series resistance and losses in the p-region resulting from the irradiation. The greater loss in fill factor observed for the n/p cells introduces the possibility that the presently observed superiority of the p/n cells may not be an intrinsic property of this configuration in GaAs

  6. Permanently calibrated interpolating time counter

    International Nuclear Information System (INIS)

    Jachna, Z; Szplet, R; Kwiatkowski, P; Różyc, K

    2015-01-01

    We propose a new architecture of an integrated time interval counter that provides its permanent calibration in the background. Time interval measurement and the calibration procedure are based on the use of a two-stage interpolation method and parallel processing of measurement and calibration data. The parallel processing is achieved by a doubling of two-stage interpolators in measurement channels of the counter, and by an appropriate extension of control logic. Such modification allows the updating of transfer characteristics of interpolators without the need to break a theoretically infinite measurement session. We describe the principle of permanent calibration, its implementation and influence on the quality of the counter. The precision of the presented counter is kept at a constant level (below 20 ps) despite significant changes in the ambient temperature (from −10 to 60 °C), which can cause a sevenfold decrease in the precision of the counter with a traditional calibration procedure. (paper)

  7. Investigation of p-n-junctions in n-InP based on voltage dependence of differential capacity

    International Nuclear Information System (INIS)

    Agaev, Ja.; Atabaev, Kh.; Gazakov, O.; Sadykov, K.B.

    1976-01-01

    The barrier capacity of alloyed p-n transitions on n-InP crystals grown by the crystallization method has been investigated. The transitions have been obtained by fusing In + 3 - 10% Zn. Step-by-step distribution of the impurity concentration in the space charge layer takes place in the alloyed diodes under investigation. The coefficient characterizing the impurity distribution in the space charge layer has been determined. The well-expressed dependence of I/C 2 =f/u) observed both at a room temperature and at the temperature of liquid nitrogen indicates that the density of ground carriers in the p-n regions are constant at a definite distance from the p-n transition. The main parameters of p-n transitions have been determined

  8. Resolution of gram quantities of racemates by high-speed counter-current chromatography.

    Science.gov (United States)

    Ma, Y; Ito, Y; Foucault, A

    1995-06-02

    Gram quantities of (+/-)-dinitrobenzoyl amino acids were separated by high-speed counter-current chromatography (CCC) using N-dodecanoyl-L-proline-3,5-dimethylanilide as a chiral selector (CS). Standard and pH-zone-refining CCC techniques were compared. By using the standard technique, 10 mg to a maximum of 1 g of samples was resolved in 2-9 h simply by increasing the concentration of the CS in the stationary phase. By using pH-zone-refining CCC, even more sample (2 g) was efficiently separated in less time (3 h). In both techniques, leakage of CS from the column was negligible. The method requires no solid support and the same column can be used repeatedly to separate a variety of enantiomers by dissolving appropriate chiral selectors in the stationary phase.

  9. Portable microcomputer controlled radiation counter

    International Nuclear Information System (INIS)

    Mason, E.W.; Weber, J.M.

    1984-01-01

    A portable microcomputer controlled counter for use as a radiation counter is described. The counter uses digital processing of input pulses from a radiation detector. The number of counts received by the microcomputer per unit time is used to calculate a value for display using a calibration factor obtained during physical calibration of the instrument with a radiation source or with a pulse generator. The keyboard is used to enter calibration points. The number of calibration points which may be entered depends on the degree of accuracy desired by the user. The high voltage generator which drives the detector is triggered by pulses from the microcomputer in relation to the count rate. After processing the count, the resulting count rate or dose rate is displayed on the liquid crystal display. The counter is autoranging in which the decimal point is shifted as necessary by the microcomputer. The units displayed are determined by the user by means of a multiposition switch. Low battery and an overrange condition are displayed. An interface is provided via a connector to allow parallel transmission of data to peripheral devices. Low battery power consumption is featured. The counter is capable of providing more accurate readings than currently available counters

  10. [ital N][sub [ital p]N[ital n

    Energy Technology Data Exchange (ETDEWEB)

    Saha, M.; Sen, S. (Saha Institute of Nuclear Physics, Calcutta 700 064 (India))

    1993-02-01

    It is shown that the well known phenomenon of the saturation in the [ital B]([ital E]2;0[sub 1][sup +][r arrow]2[sub 1][sup +]), as well as the [ital E][sub 21][sup +] values near midshell in the even rare-earth and actinide nuclei, can be reproduced in the [ital N][sub [ital p]N[ital n

  11. Total (p,n) and (α,n) cross sections for nucleosynthesis and nuclear applications. Project report, 1 June 1980-28 February 1981

    International Nuclear Information System (INIS)

    Gabbard, F.; Hershberger, R.L.

    1981-01-01

    The work proposed for the two-year program has as its objective (1) measurement of selected total (p,n) and (α,n) reaction cross sections using a 4π neutron counter; (2) calculation of stellar reaction rates for the reactions measured and, when feasible, for the inverse reactions and comparison with model calculations of the cross sections; and (3) comparison of the measured cross sections with computed values using global optical potentials for the purpose of studying the systematics of the potentials as a function of atomic mass number, A, and the energy of the bombarding particle. An important part of the work is to study the systematics of the imaginary part of the potentials, W. The elements selected for study during the two-year period were 51 V, 54 Cr, 61 Ni, 64 Ni, 65 Cu, 67 Zn, 68 Zn, and 75 As. During the first nine month period (1 June 1980-28 February 1981) of the project, work has been done on 51 V, /sup Nat/Ni, /sup Nat/Zn, /sup Nat/Cu and 75 As. Progress is reported

  12. Study of J/psi -> p(p)over-bar and J/psi -> n(n)over-bar

    NARCIS (Netherlands)

    Ablikim, M.; Achasov, M. N.; Ambrose, D. J.; An, F. F.; An, Q.; An, Z. H.; Bai, J. Z.; Ban, Y.; Becker, J.; Berger, N.; Bertani, M.; Bian, J. M.; Boger, E.; Bondarenko, O.; Boyko, I.; Briere, R. A.; Bytev, V.; Cai, X.; Calcaterra, A.; Cao, G. F.; Chang, J. F.; Chelkov, G.; Chen, G.; Chen, H. S.; Chen, J. C.; Chen, M. L.; Chen, S. J.; Chen, Y.; Chen, Y. B.; Cheng, H. P.; Chu, Y. P.; Cronin-Hennessy, D.; Dai, H. L.; Dai, J. P.; Dedovich, D.; Deng, Z. Y.; Denig, A.; Denysenko, I.; Destefanis, M.; Ding, W. M.; Ding, Y.; Dong, L. Y.; Dong, M. Y.; Du, S. X.; Fang, J.; Fang, S. S.; Fava, L.; Feldbauer, F.; Feng, C. Q.; Ferroli, R. B.; Fu, C. D.; Fu, J. L.; Gao, Y.; Geng, C.; Goetzen, K.; Gong, W. X.; Gradl, W.; Greco, M.; Gu, M. H.; Gu, Y. T.; Guan, Y. H.; Guo, A. Q.; Guo, L. B.; Guo, Y. P.; Han, Y. L.; Hao, X. Q.; Harris, F. A.; He, K. L.; He, M.; He, Z. Y.; Held, T.; Heng, Y. K.; Hou, Z. L.; Hu, H. M.; Hu, J. F.; Hu, T.; Huang, B.; Huang, G. M.; Huang, J. S.; Huang, X. T.; Huang, Y. P.; Hussain, T.; Ji, C. S.; Ji, Q.; Ji, X. B.; Ji, X. L.; Jia, L. K.; Jiang, L. L.; Jiang, X. S.; Jiao, J. B.; Jiao, Z.; Jin, D. P.; Jin, S.; Jing, F. F.; Kalantar-Nayestanaki, N.; Kavatsyuk, M.; Kuehn, W.; Lai, W.; Lange, J. S.; Leung, J. K. C.; Li, C. H.; Li, Cheng; Li, Cui; Li, D. M.; Li, F.; Li, G.; Li, H. B.; Li, J. C.; Li, K.; Li, Lei; Li, N. B.; Li, Q. J.; Li, S. L.; Li, W. D.; Li, W. G.; Li, X. L.; Li, X. N.; Li, X. Q.; Li, X. R.; Li, Z. B.; Liang, H.; Liang, Y. F.; Liang, Y. T.; Liao, G. R.; Liao, X. T.; Liu, B. J.; Liu, B. J.; Liu, C. L.; Liu, C. X.; Liu, C. Y.; Liu, F. H.; Liu, Fang; Liu, Feng; Liu, H.; Liu, H. B.; Liu, H. H.; Liu, H. M.; Liu, H. W.; Liu, J. P.; Liu, K. Y.; Liu, Kai; Liu, Kun; Liu, P. L.; Liu, S. B.; Liu, X.; Liu, X. H.; Liu, Y.; Liu, Y. B.; Liu, Z. A.; Liu, Zhiqiang; Liu, Zhiqing; Loehner, H.; Lu, G. R.; Lu, H. J.; Lu, J. G.; Lu, Q. W.; Lu, X. R.; Lu, Y. P.; Luo, C. L.; Luo, M. X.; Luo, T.; Luo, X. L.; Lv, M.; Ma, C. L.; Ma, F. C.; Ma, H. L.; Ma, Q. M.; Ma, S.; Ma, T.; Ma, X. Y.; Ma, Y.; Maas, F. E.; Maggiora, M.; Malik, Q. A.; Mao, H.; Mao, Y. J.; Mao, Z. P.; Messchendorp, J. G.; Min, J.; Min, T. J.; Mitchell, R. E.; Mo, X. H.; Morales, C. Morales; Motzko, C.; Muchnoi, N. Yu.; Nefedov, Y.; Nicholson, C.; Nikolaev, I. B.; Ning, Z.; Olsen, S. L.; Ouyang, Q.; Pacetti, S.; Park, J. W.; Pelizaeus, M.; Peters, K.; Ping, J. L.; Ping, R. G.; Poling, R.; Prencipe, E.; Pun, C. S. J.; Qi, M.; Qian, S.; Qiao, C. F.; Qin, X. S.; Qin, Y.; Qin, Z. H.; Qiu, J. F.; Rashid, K. H.; Rong, G.; Ruan, X. D.; Sarantsev, A.; Schulze, J.; Shao, M.; Shen, C. P.; Shen, X. Y.; Sheng, H. Y.; Shepherd, M. R.; Song, X. Y.; Spataro, S.; Spruck, B.; Sun, D. H.; Sun, G. X.; Sun, J. F.; Sun, S. S.; Sun, X. D.; Sun, Y. J.; Sun, Y. Z.; Sun, Z. J.; Sun, Z. T.; Tang, C. J.; Tang, X.; Thorndike, E. H.; Tian, H. L.; Toth, D.; Ullrich, M.; Varner, G. S.; Wang, B.; Wang, B. Q.; Wang, K.; Wang, L. L.; Wang, L. S.; Wang, M.; Wang, P.; Wang, P. L.; Wang, Q.; Wang, Q. J.; Wang, S. G.; Wang, X. F.; Wang, X. L.; Wang, Y. D.; Wang, Y. F.; Wang, Y. Q.; Wang, Z.; Wang, Z. G.; Wang, Z. Y.; Wei, D. H.; Weidenkaff, P.; Wen, Q. G.; Wen, S. P.; Werner, M.; Wiedner, U.; Wu, L. H.; Wu, N.; Wu, S. X.; Wu, W.; Wu, Z.; Xia, L. G.; Xiao, Z. J.; Xie, Y. G.; Xiu, Q. L.; Xu, G. F.; Xu, G. M.; Xu, H.; Xu, Q. J.; Xu, X. P.; Xu, Y.; Xu, Z. R.; Xue, F.; Xue, Z.; Yan, L.; Yan, W. B.; Yan, Y. H.; Yang, H. X.; Yang, T.; Yang, Y.; Yang, Y. X.; Ye, H.; Ye, M.; Ye, M. H.; Yu, B. X.; Yu, C. X.; Yu, J. S.; Yu, S. P.; Yuan, C. Z.; Yuan, W. L.; Yuan, Y.; Zafar, A. A.; Zallo, A.; Zeng, Y.; Zhang, B. X.; Zhang, B. Y.; Zhang, C. C.; Zhang, D. H.; Zhang, H. H.; Zhang, H. Y.; Zhang, J.; Zhang, J. G.; Zhang, J. Q.; Zhang, J. W.; Zhang, J. Y.; Zhang, J. Z.; Zhang, L.; Zhang, S. H.; Zhang, T. R.; Zhang, X. J.; Zhang, X. Y.; Zhang, Y.; Zhang, Y. H.; Zhang, Y. S.; Zhang, Z. P.; Zhang, Z. Y.; Zhao, G.; Zhao, H. S.; Zhao, J. W.; Zhao, K. X.; Zhao, Lei; Zhao, Ling; Zhao, M. G.; Zhao, Q.; Zhao, S. J.; Zhao, T. C.; Zhao, X. H.; Zhao, Y. B.; Zhao, Z. G.; Zhemchugov, A.; Zheng, B.; Zheng, J. P.; Zheng, Y. H.; Zheng, Z. P.; Zhong, B.; Zhong, J.; Zhou, L.; Zhou, X. K.; Zhou, X. R.; Zhu, C.; Zhu, K.; Zhu, K. J.; Zhu, S. H.; Zhu, X. L.; Zhu, X. W.; Zhu, Y. M.; Zhu, Y. S.; Zhu, Z. A.; Zhuang, J.; Zou, B. S.; Zou, J. H.; Zuo, J. X.

    2012-01-01

    The decays J/psi -> p (p) over bar and J/psi -> n (n) over bar have been investigated with a sample of 225.2 x 10(6) J/psi events collected with the BESIII detector at the BEPCII e(+)e(-) collider. The branching fractions are determined to be B(J/psi -> p (p) over bar) = (2.112 +/- 0.004 +/- 0.031 x

  13. What is Counter-Enlightenment?

    Directory of Open Access Journals (Sweden)

    Darrin M. McMahon

    2017-02-01

    Full Text Available This article counters recent suggestions that there was no such thing as a “Counter-Enlightenment” or “Counter-Enlightenments,” and that such terms ought thus to be abandoned.   While acknowledging inevitable difficulties with the terms, the article argues that there can be no doubting the reality.   European countries faced a variety of vehement and self-conscious movements that defined themselves precisely through their opposition to what they took to be the corrosive effects of the Enlightenment.  In the process, they defined the main terms of an enduring vision of the world that we now associate with the Right.

  14. Dual functional reduced graphene oxide as photoanode and counter electrode in dye-sensitized solar cells and its exceptional efficiency enhancement

    Science.gov (United States)

    Jumeri, F. A.; Lim, H. N.; Zainal, Z.; Huang, N. M.; Pandikumar, A.; Lim, S. P.

    2015-10-01

    The dual functionalities of reduced graphene oxide (rGO) as photoanode and counter electrode in dye-sensitized solar cells (DSSCs) is explored. A titanium dioxide (TiO2) film is deposited on an indium tin oxide (ITO) glass using an in-house aerosol-assisted chemical vapor deposition method. Graphene oxide (GO) is then introduced onto the TiO2-ITO substrate, and the GO layer is successively thermally treated to rGO. The TiO2-rGO film is used as a compact layer for the photoanode of the DSSC. A layer of zinc oxide-silver (ZnO-Ag) is introduced on top of the compact layer as an active material. Its highly porous flower-shaped morphology is advantageous for the adsorption of dye. The in-situ electrochemical polymerization method used for the fabrication of polypyrrole incorporated with rGO and p-toluenesulfonate (pTS) (Ppy-rGO-pTS) on an ITO glass is used as a counter electrode for the DSSC. The DSSC assembled with the Ppy-rGO-1.0pTS counter electrode exhibites an enhanced conversion efficiency of 1.99% under solar illumination, which is better than that using conventional Pt as a counter electrode (0.08%). This is attributed to the increased contact area between the Ppy-rGO-pTS counter electrode and electrolyte, which subsequently improves the conductivity and high electrocatalytic activities of the Ppy-rGO-pTS counter electrode.

  15. Experiments on iron shield transmission of quasi-monoenergetic neutrons generated by 43- and 68-MeV protons via the 7Li(p,n) reaction

    International Nuclear Information System (INIS)

    Nakashima, Hiroshi; Tanaka, Shun-ichi; Nakao, Noriaki

    1996-03-01

    In order to provide benchmark data of neutrons transmitted through iron shields in the intermediate-energy region, spatial distributions of neutron energy spectra and reaction rates behind and inside the iron shields of thickness up to 130 cm were measured for 43- and 68-MeVp- 7 Li neutrons using a quasi-monoenergetic neutron beam source at the 90-MV AVF cyclotron facility of the TLARA facility in JAERI. The measured data by five kinds of detectors: the BC501A detector, the Bonner ball counter, 238 U and 232 Th fission counters, 7 LiF and nat LiF TLDs and solid state nuclear track detector, are numerically provided in this report in the energy region between 10 -4 eV and the energy of peak neutrons generated by the 7 Li(p,n) reaction. (author)

  16. A Study of the Angular Distributions of Neutrons from the {sup 9}Be (p,n) {sup 9}B Reaction at Low Proton Energies

    Energy Technology Data Exchange (ETDEWEB)

    Antolkovic, B; Holmqvist, B; Wiedling, T

    1964-10-15

    The angular distributions of neutrons from the reaction {sup 9}Be (p, n) {sup 9}B have been studied at the proton energies 2.300, 2.335, 2.389, and 2.560 MeV. Time-of-flight techniques have been used. The angular distribution measurements show remarkable differences compared to earlier published results using long-counters as detectors. The new results are ascribed to the different experimental methods. By using time-of-flight techniques it has been possible to eliminate disturbing influences from neutrons obtained from the {sup 9}Be (p,p'n) {sup 8}Be reaction which has a lower reaction threshold than the {sup 9}Be (p, n) {sup 9}B reaction as well as other Be-p-reactions emitting neutrons. The experimental distribution at 2.30 MeV has been compared with the simplified theories for direct interaction processes developed by Satchler and Rodberg. It is shown that Rodberg's proposal of using optical model wave functions describes the experiment better than Satchler's original theory. However, a good fitting leads to a nuclear radius as well as an optical potential which is appreciably smaller than ordinarily obtained in scattering experiments.

  17. Nuclear timer/counter

    International Nuclear Information System (INIS)

    Wuthayavanich, S.

    1978-01-01

    This thesis represents the development of a Timer/COUNTER compatible to the standard Nuclear Instrument Module Specifications. The unit exhibits high accuracy, light weight and ease of maintenance. The unit also has a built-in precision discriminator to discriminate unwanted signals that may cause interference in counting. With line frequency time base the timer can be preset in steps from 0.1 sec. to 9 x 10 5 min. The counter with six digits miniature display and an overflow output has a maximum counting rate of 10 MHz. The accumulated counting data can be transferred to a teletype or printer for hard copy printout with the aid of ORTEC 777 Line Printer or 432 A Print-out Control or any print out interface with input compatible to the print output of the Timer/Counter. Owing to its NIM compatibility the unit is directly powered by the NIM power supply

  18. P-GaN/ZnO nanorod heterojunction LEDs—effect of carrier concentration in p-GaN

    Science.gov (United States)

    Ng, A. M. C.; Chen, X. Y.; Fang, F.; Djurišić, A. B.; Chan, W. K.; Cheah, K. W.

    2011-12-01

    We studied the effect of carrier concentration in p-GaN substrate on the performance of p-GaN/n-ZnO nanorod heterojunction LEDs. ZnO nanorods were electrodeposited on commercial p-GaN wafers in a two electrode system from aqueous solutions of zinc nitrate and hexamethylenetetramine. The morphology and optical properties of ZnO nanorods were studied using photoluminescence and electron microscopy, and the LED device performance was studied by electroluminescence (EL) and I-V measurements.

  19. Improved efficiency of CdS quantum dot sensitized solar cell with an organic redox couple and a polymer counter electrode

    International Nuclear Information System (INIS)

    Shu, Ting; Li, Xiong; Ku, Zhi-Liang; Wang, Shi; Wu, Shi; Jin, Xiao-Hong; Hu, Chun-Di

    2014-01-01

    Highlights: • The organic AT - /BAT and T - /T 2 redox couples were used in CdS QDSSCs. • The AT - /BAT and PEDOT are better than polysulfide electrolyte and Pt and CoS CEs. • An improved η of 1.53% was obtained with the AT - /BAT electrolyte and the PEDOT CE. • PEDOT CE deposited at high deposition charge has better electrochemical activity. • The AT - /BAT outperformed T - /T 2 electrolyte due to suppressed charge recombination. - Abstract: Quantum dot sensitized solar cells (QDSSCs) based on an organic thiolate/disulfide redox couple (C 7 H 5 N 4 S - /C 14 H 10 N 8 S 2 or C 2 H 3 N 4 S - /C 4 H 6 N 8 S 2 ) and a polymer counter electrode [poly (3, 4-ethylenedioxythiophene), PEDOT] were fabricated and their photovoltaic performance were investigated. In CdS QDSSC, the organic C 7 H 5 N 4 S - /C 14 H 10 N 8 S 2 electrolyte shows better performance than the polysulfide electrolyte, and the PEDOT counter electrode exhibits higher efficiency than that of the Pt counter electrode and the CoS counter electrode. An efficiency of 1.53% was achieved in this QDSSC. The influences of the morphology and the deposition charge of the PEDOT counter electrodes on the cell performance were also studied. Furthermore, it was found that the C 7 H 5 N 4 S - /C 14 H 10 N 8 S 2 redox couple outperformed the C 2 H 3 N 4 S - /C 4 H 6 N 8 S 2 redox couple due to reduced electron recombination

  20. Re-evaluation of microscopic and integral cross-section data for important dosimetry reactions. Re-evaluation of the excitation functions for the 24Mg(n,p)24Na, 32S(n,p)32P, 60Ni(n,p)60m+gCo, 63Cu(n,2n)62Cu, 65Cu(n,2n)64Cu, 64Zn(n,p)64Cu, 115In(n,2n)114mIn, 127I(n,2n)126I, 197Au(n,2n)196Au and 199Hg(n,n')199mHg reactions

    International Nuclear Information System (INIS)

    Zolotarev, K.I.

    2008-08-01

    Re-evaluations of cross sections and their associated covariance matrices have been carried out for ten dosimetry reactions: - excitation functions for the 63 Cu(n,2n) 62 Cu, 65 Cu(n,2n) 64 Cu, 64 Zn(n,p) 64 Cu, 115 In(n,2n) 114m In and 199 Hg(n,n') 199m Hg reactions were re-evaluated over the neutron energy range from threshold to 20 MeV; - excitation functions for the 24 Mg(n,p) 24 Na, 32 S(n,p) 32 P and 60 Ni(n,p) 60m+g Co were reevaluated in the energy range from threshold to 21 MeV; - excitation functions for the 127 I(n,2n) 126 I and 197 Au(n,2n) 196 Au reactions were reevaluated in the energy range from threshold to 32 and 40 MeV, respectively. Benchmark calculations performed for 235 U thermal fission and 252 Cf spontaneous fission neutron spectra show that the integral cross sections derived from the newly evaluated excitation functions exhibit improved agreement with related experimental data when compared with the equivalent data from the IRDF-2002 library. (author)

  1. Systematics in p-n interaction vs deformation

    International Nuclear Information System (INIS)

    Singh, M.; Singh, Yuvraj; Kumar, Rajesh; Vrshney, A.K.; Gupta, K.K.

    2017-01-01

    The correlation of integrated valance p-n interaction in the onset of collectivity and deformation has been described phenomenologically in terms of N p N n scheme. L. Esser et al. presented the graphs between N p N n and deformation β and γ for some heavy nuclei

  2. The first CEDAR counter

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The first differential Cerenkov counter with chromatic corrections (called CEDAR) successfully tested at the PS in July 75. These counters were used in the SPS hadronic beams for particle identification. Some of the eight photomultipliers can be seen: they receive the light reflected back through the annular diaphragm. René Maleyran stands on the left.

  3. Multiplication in Silicon p-n Junctions

    DEFF Research Database (Denmark)

    Moll, John L.

    1965-01-01

    Multiplication values were measured in the collector junctions of silicon p-n-p and n-p-n transistors before and after bombardment by 1016 neutrons/cm2. Within experimental error there was no change either in junction fields, as deduced from capacitance measurements, or in multiplication values i...

  4. (p, p') and (p, n) reactions on halo nuclei

    International Nuclear Information System (INIS)

    Satou, Y; Nakamura, T; Fukuda, N; Sugimoto, T; Kondo, Y; Matsui, N; Hashimoto, Y; Nakabayashi, T; Okumura, T; Shinohara, M; Motobayashi, T; Yanagisawa, Y; Aoi, N; Takeuchi, S; Gomi, T; Togano, Y; Kawai, S; Sakurai, H; Ong, H J; Onishi, T K; Shimoura, S; Tamaki, M; Kobayashi, T; Otsu, H; Matsuda, Y; Endo, N; Kitayama, M; Ishihara, M

    2006-01-01

    We have measured the 1 H( 19 C, 18 C+n) 1 H and 1 H( 14 Be, 13 B+n)n reactions at 70 MeV/nucleon using the invariant mass method in inverse kinematics. A new state was identified at 1.49 MeV in 19 C. In the latter (p, n) reaction, a resonance peak corresponding to the 1.28 MeV state in 14 B recently reported in a beta-decay study was clearly observed. Forward peaked character in the differential cross section supports the 1 + assignment for this state

  5. Electronic device for measuring the polarization parameter in the π-p → π0n charge exchange reaction on a polarized proton target

    International Nuclear Information System (INIS)

    Brehin, S.

    1967-12-01

    An electronic apparatus has been constructed to measure the polarization parameter P 0 (t) in π - p → π 0 n charge exchange scattering at 5.9 GeV/c and 11,2 GeV/c on polarized proton target. This device insures triggering of a heavy plate spark chamber, allowing visualisation of γ rays from the π 0 decays when the associated neutron offers suitable characteristics in direction and energy. The neutron is detected by an array of 32 counters and his energy is measured by a time of flight method. Electronic circuits of this apparatus are described as test and calibration methods used. (author) [fr

  6. N-Doped graphene nanoplatelets as superior metal-free counter electrodes for organic dye-sensitized solar cells.

    Science.gov (United States)

    Ju, Myung Jong; Kim, Jae Cheon; Choi, Hyun-Jung; Choi, In Taek; Kim, Sang Gyun; Lim, Kimin; Ko, Jaejung; Lee, Jae-Joon; Jeon, In-Yup; Baek, Jong-Beom; Kim, Hwan Kyu

    2013-06-25

    Highly efficient counter electrodes (CEs) for dye-sensitized solar cells (DSSCs) were developed using thin films of scalable and high-quality, nitrogen-doped graphene nanoplatelets (NGnP), which was synthesized by a simple two-step reaction sequence. The resultant NGnP was deposited on fluorine-doped SnO2 (FTO)/glass substrates by using electrospray (e-spray) coating, and their electrocatalytic activities were systematically evaluated for Co(bpy)3(3+/2+) redox couple in DSSCs with an organic sensitizer. The e-sprayed NGnP thin films exhibited outstanding performances as CEs for DSSCs. The optimized NGnP electrode showed better electrochemical stability under prolonged cycling potential, and its Rct at the interface of the CE/electrolyte decreased down to 1.73 Ω cm(2), a value much lower than that of the Pt electrode (3.15 Ω cm(2)). The DSSC with the optimized NGnP-CE had a higher fill factor (FF, 74.2%) and a cell efficiency (9.05%), whereas those of the DSSC using Pt-CE were only 70.6% and 8.43%, respectively. To the best of our knowledge, the extraordinarily better current-voltage characteristics of the DSSC-NGnP outperforming the DSSC-Pt for the Co(bpy)3(3+/2+) redox couple (in paticular, FF and short circuit current, Jsc) is highlighted for the first time.

  7. Proportional counter end effects eliminator

    International Nuclear Information System (INIS)

    Meekins, J.F.

    1976-01-01

    An improved gas-filled proportional counter which includes a resistor network connected between the anode and cathode at the ends of the counter in order to eliminate ''end effects'' is described. 3 Claims, 2 Drawing Figures

  8. Fiber-Optic Monitoring System of Particle Counters

    Directory of Open Access Journals (Sweden)

    A. A. Titov

    2016-01-01

    Full Text Available The article considers development of a fiber-optic system to monitor the counters of particles. Presently, optical counters of particles, which are often arranged at considerable distance from each other, are used to study the saltation phenomenon. For monitoring the counters, can be used electric communication lines.However, it complicates and raises the price of system Therefore, we offered a fiber-optic system and the counter of particles, free from these shortcomings. The difference between the offered counter of particles and the known one is that the input of radiation to the counter and the output of radiation scattering on particles are made by the optical fibers, and direct radiation is entered the optical fiber rather than is delayed by a light trap and can be used for lighting the other counters thereby allowing to use their connection in series.The work involved a choice of the quartz multimode optical fiber for communication, defining the optical fiber and lenses parameters of the counter of particles, and a selection of the radiation source and the photo-detector.Using the theory of light diffraction on a particle, a measuring range of the particle sizes has been determined. The system speed has been estimated, and it has been shown that a range of communication can reach 200km.It should be noted that modulation noise of counters of particles connected in series have the impact on the useful signal. To assess the extent of this influence we have developed a calculation procedure to illustrate that with ten counters connected in series this influence on the signal-to-noise ratio will be insignificant.Thus, it has been shown that the offered fiber-optic system can be used for monitoring the counters of particles across the desertified territories. 

  9. Interpretation of some (p,n), (n,p), and (3He, p) reactions by means of the statistical multistep compound emission theory

    International Nuclear Information System (INIS)

    Bonetti, R.; Milazzo, L.C.; Melanotte, M.

    1983-01-01

    A number of (p,n), (n,p), and ( 3 He, p) reactions have been interpreted on the basis of the statistical multistep compound emission mechanism. Good agreement with experiment is found both in spectrum shape and in the value of the coherence widths

  10. Evaluation of Some (n,n'), (n,γ), (n,p), (n,2n) and (n,3n) Reaction Excitation Functions for Fission and Fusion Reactor Dosimetry Applications; Evaluation of the Excitation Functions for the 54Fe(n,p)54Mn, 58Ni(n,2n)57Ni, 67Zn(n,p)67Cu, 92Mo(n,p)92mNb, 93Nb(n,γ)94Nb, 113In(n,n')113mIn, 115In(n,γ) 116mIn, and 169Tm(n,3n)167Tm Reactions. Progress Report on Research Contract No 16242

    International Nuclear Information System (INIS)

    Zolotarev, K.I.; Zolotarev, P.K.

    2013-12-01

    Cross section data for the 54 Fe(n,p) 54 Mn, 58 Ni(n,2n) 57 Ni, 67 Zn(n,p) 67 Cu, 92 Mo(n,p) 92m Nb, 93 Nb(n,γ) 94 Nb, 113 In(n,n') 113m In, 115 In(n,γ) 116m In, 169 Tm(n,3n) 167 Tm reactions are needed to solve a wide spectrum of scientific and technical tasks. Activation detectors based on these reactions may be used in the field of reactor dosimetry. Furthermore, the 54 Fe(n,p) 54 Mn reaction is often used in experimental nuclear physics as a monitor reaction for measurements of unknown cross sections by means of the activation method over the neutron energy range from 5 to 15 MeV. The 93 Nb(n,γ) 94 Nb reaction is also very promising for using in retrospective neutron dosimetry for determination of total neutron fluence during a campaign of a reactor. In the existing version of the International Reactor Dosimetry File and the new extended version named as IRDFF data for excitation functions of 67 Zn(n,p) 67 Cu, 92 Mo(n,p) 92m Nb, 113 In(n,n') 113m In, and 169 Tm(n,3n) 167 Tm reactions are absent. Data for these reactions are also absent in the JENDL/D-99 dosimetry file. Excitation functions of 67 Zn(n,p) 67 Cu and 169 Tm(n,3n) 167 Tm are presented in the TENDL-2012, EAF-2010, JENDL-4.0, JEFF-3.1/A, MENDL-2 libraries. Cross section data for the 67 Zn(n,p) 67 Cu reaction up to 20 MeV are given also in the JENDL/HE-2007 library. Excitation functions of the 92 Mo(n,p) 92m Nb and 113 In(n,n') 113m In reactions are evaluated in the EAF-2010 and JEFF-3.1/A libraries. Cross section data for the 113 In(n,n') 113m In reaction are given also in the TENDL-2010 library. It is necessary to note that neutron data in the JEFF-3.1/A and JENDL-4.0 libraries were evaluated up to 20 MeV. Neutron data in the TENDL-2012, EAF-2010, MENDL-2 and TENDL-2010 libraries had been evaluated up to 30 MeV, 60 MeV, 100 MeV and 200 MeV, respectively. Neutron cross sections in the MENDL-2, TENDL-2010 and TENDL-2012 libraries had been obtained on the basis of pure theoretical model calculations

  11. Antipruritic Effect of Cold-induced and Transient Receptor Potential-agonist-induced Counter-irritation on Histaminergic Itch in Humans.

    Science.gov (United States)

    Andersen, Hjalte H; Melholt, Camilla; Hilborg, Sigurd D; Jerwiarz, Anne; Randers, Amalie; Simoni, Amalie; Elberling, Jesper; Arendt-Nielsen, Lars

    2017-01-04

    A frequent empirical observation is that cold-induced counter-irritation may attenuate itch. The aim of this randomized, single-blinded, exploratory study was to evaluate the counter-irritation effects of cold-stimulation and topical application of transient receptor potential TRPA1/M8-agonists (trans-cinnamaldehyde/L-menthol, respectively), on histamine-induced itch, wheals and neurogenic inflammation in 13 healthy volunteers. Histamine 1% was applied to the volar forearms using skin prick-test lancets. Recorded outcome-parameters were itch intensity, wheal reactions, and neurogenic inflammation (measured by laser-speckle perfusion-imaging). Homotopic thermal counter-irritation was performed with 6 temperatures, ranging from 4°C to 37°C, using a 3 × 3-cm thermal stimulator. Chemical "cold-like" counter-irritation was conducted with 40% L-menthol and 10% trans-cinnamaldehyde, while 5% doxepin was used as a positive antipruritic control/comparator. Cold counter-irritation stimuli from 4°C to 22°C inhibited itch in a stimulus-intensity-dependent manner (p cold-like" counter-irritation with both L-menthol and trans-cinnamaldehyde had antipruritic efficacy similar to doxepin (p Cold-induced counter-irritation had an inhibitory effect on histaminergic itch, suggesting that agonists of cold transduction receptors could be of potential antipruritic value.

  12. (p,n) and (n,p) reactions as probes of isovector giant monopole resonances

    International Nuclear Information System (INIS)

    Auerbach, N.; Bowman, J.D.; Franey, M.A.; Love, W.G.

    1983-01-01

    Nucleon charge exchange reactions are explored as prospective probes of isovector giant monopole resonances. Using charge exchange transition densities based on random-phase approximation sum rules, distorted wave impulse approximation calculations are made for the (p,n) and (n,p) reactions exciting the isovector giant monopole resonances in several nuclei at bombarding energies of 120 and 800 MeV. Based on our calculations, the charge exchange reactions at 800 MeV appear more promising

  13. Counter-Narratives and the Unrehearsed Stories Counter-Terrorists Unwittingly Produce

    Directory of Open Access Journals (Sweden)

    Beatrice de Graaf

    2010-11-01

    Full Text Available Governments produce both deliberate and involuntary (and less conscious narratives when countering terrorism. The thesis of this article is that such unintended messages can be much more powerful and consequential than is realized; in fact, they can completely contradict the intended official 'counter-narrative'. To substantiate this hypothesis, the author looks at the experience of the German Federal Republic in the 1970s and beyond when state and society were confronted with the Red Army Faction (RAF and similar left-wing "revolutionaries" like those of the 2nd of June Movement or the Red Zora.

  14. Real-time {sup 90}Sr Counter

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Naomi; Kawai, Hideyuki; Kodama, Satoshi; Kobayashi, Atsushi; Tabata, Makoto; Ito, Hiroshi [Graduate School of Science, Chiba University, Chiba, (Japan); Han, Soorim [Graduate School of Science, Chiba University, Chiba, (Japan); National Institute of Radiological Science, Chiba, (Japan)

    2015-07-01

    Radioisotopes have been emitted around Japan due to a nuclear accident at the Fukushima Daiichi nuclear power station in March 2011. A problem is the contaminated water including the atomic nucleus which relatively has a long half- life time and soluble such as {sup 90}Sr, {sup 137}Cs. Internal exposures by {sup 90}Sr are more dangerous than {sup 137}Cs's because Sr has effective half-life time of 18 years and property of accumulation in a born. We have developed real-time {sup 90}Sr counter which is sensitive beta-ray of maximum kinematic energy of 2.28 MeV from {sup 90}Sr and insensitive of beta-ray of maximum kinematic energy of 1.17 MeV and gamma-ray from {sup 90}Sr by Cherenkov detection. This counter composes of Cerenkov counter, trigger scintillation counter and veto counter. Silica aerogel for Cherenkov counter can obtain refractive index between 1.017 and 1.049 easily. And wavelength shifting fiber (WLSF) is used as a light guide for extending effective area and producing lower cost. A mechanism of the identification of {sup 90}Sr is explained in following. In case of {sup 90}Sr, when the trigger counter reacts on the beta-ray from {sup 90}Sr, aerogel emits the Cherenkov light and WLSF reacts and read the Cherenkov light. On the other hand, in case of {sup 137}Cs, the trigger counter reacts on the beta-ray, aerogel stops the beta- ray and Cherenkov light is not emitted. Therefore, aerogel has a function as a radiator and shielding material. the gamma-ray is not reacted on the lower density detector. Cosmic rays would be also reacted by the veto counter. A prototype counter whose the effective area is 30 cm x 10 cm was obtained (2.0±1.2){sup 3} of mis-identification as {sup 137}Cs/{sup 90}Sr. Detection limit in the surface contamination inspection depends on measurement time and effective area mainly. The sensitivity of wide range, 10{sup -2} - 10{sup 4} Bq/cm{sup 2}, is obtained by adjustment of detection level in circuit of this counter. A lower

  15. Plea and counter-plea

    International Nuclear Information System (INIS)

    1979-06-01

    The bulk of papers written during the hearing 'Plea and counter-plea', the so-called 'Gorleben hearing', which was held from 28th March until 3rd April 1979, comprises ca. 4,200 pages. It consists of the written comments put forward by the critics of nuclear energy, the minutes of the hearing as well as the supplementary statements of the counter-critics. This report is trying to confront those essential objections made by the critics which put in doubt the feasibility of a fuel-cycle centre with regard to safety engineering with the facts which are considered correct from the view of the DWK. The oral and written explanations of the counter-critics are particularly referred to in this debate. (orig./HP) [de

  16. Multiple channel programmable coincidence counter

    Science.gov (United States)

    Arnone, Gaetano J.

    1990-01-01

    A programmable digital coincidence counter having multiple channels and featuring minimal dead time. Neutron detectors supply electrical pulses to a synchronizing circuit which in turn inputs derandomized pulses to an adding circuit. A random access memory circuit connected as a programmable length shift register receives and shifts the sum of the pulses, and outputs to a serializer. A counter is input by the adding circuit and downcounted by the seralizer, one pulse at a time. The decoded contents of the counter after each decrement is output to scalers.

  17. Total (p,n), (p,γ), (p,p'γ) and differential (p,p) cross-sections measurements for /sup 61,64/Ni

    International Nuclear Information System (INIS)

    Hershberger, R.L.; Gabbard, F.; Laird, C.E.

    1985-01-01

    Absolute total (p,n) and differential elastic (p,p) cross sections have been measured for /sup 61,64/Ni in the energy range of E/sub p/ = 2 to 7 MeV. The (p,γ) and (p,p'γ) cross sections were measured from as low an energy as feasible to approximately one MeV above the (p,n) threshold. Standard optical potentials have been used with a Hauser-Feshbach model to analyze the data. The adopted model values are used to deduce a total proton strength function which displays features of the 3s single particle resonance

  18. Aerogel Cherenkov Counters of the KEDR Detector

    CERN Document Server

    Ovtin, I V; Barnyakov, M Y; Bobrovnikov, V S; Buzykaev, A R; Danilyuk, A F; Katcin, A A; Kononov, S A; Kravchenko, E A; Kuyanov, I A; Onuchin, A P; Rodiakin, V A

    2017-01-01

    The particle identification system of the KEDR detector is based on aerogel threshold Cherenkov counters called ASHIPH counters. The system consists of 160 counters arranged in two layers. An event reconstruction program for the ASHIPH system was developed. The position of each counter relative to the tracking system was determined using cosmic muons and Bhabha events. The geometric efficiency of the ASHIPH system was verified with Bhabha events. The efficiency of relativistic particle detection was measured with cosmic muons. A π/K separation of 4δ in the momentum range 0.95 −1.45 GeV/c was confirmed. A simulation program for the ASHIPH counters has been developed.

  19. Evaluation of in-plant neutron coincidence counters for the measurement of molten salt extraction residues

    International Nuclear Information System (INIS)

    Langner, D.G.; Russo, P.A.; Wachter, J.R.

    1993-01-01

    Americium is extracted from plutonium by a molten salt extraction (MSE) process. The residual americium-laden salts are a significant waste stream in this pyrochemical purification process. Rapid assay of MSE residues is desirable to minimize the exposure of personnel to these often high-level emissions. However, the quantitative assay of plutonium in MSE residues is difficult. Variable, unknown (a,n) rates and variable emitted-neutron energy spectra preclude the use of standard neutron coincidence counting techniques with old-generation neutron coincidence counters. Gamma-ray assay methods have not been successful with some residues because of random lumps of plutonium metal. In this paper, we present measurements of MSE residues with two state-of-the-art neutron coincidence counters at the Los Alamos Plutonium Processing Facility: an in-line counter built for the assay of bulk waste material and the pyrochemical multiplicity counter that underwent test and evaluation at that facility. Both of these counters were designed to minimize the effects on measurements of variations in the sample geometry and variable energy spectra of emitted neutrons. These results are compared to measurements made with an HLNCII and with a 20-yr-old in-line well counter. The latter two counters are not optimized in ft sense. We conclude that the newer counters provide significantly improved assay results. The pyrochemical multiplicity counter operated in the conventional coincidence mode provided the best assays overall

  20. Construction of silica aerogel radiator system for Belle II RICH Counter

    Science.gov (United States)

    Adachi, I.; Dolenec, R.; Hataya, K.; Iori, S.; Iwata, S.; Kakuno, H.; Kataura, R.; Kawai, H.; Kindo, H.; Kobayashi, T.; Korpar, S.; Križan, P.; Kumita, T.; Mrvar, M.; Nishida, S.; Ogawa, K.; Ogawa, S.; Pestotnik, R.; Šantelj, L.; Sumiyoshi, T.; Tabata, M.; Yonenaga, M.; Yusa, Y.

    2017-12-01

    We have developed a RICH counter as a new forward particle identification device for the Belle II experiment. As a Cherenkov radiator in this counter, a dual aerogel layer combination consisting of two refractive indicies, n=1.045 and 1.055, is employed. Mass production of these aerogel tiles has been done during 2013-2014 with new method improved by Chiba group. Optical qualities for them have been examined. The refractive indices of the obtained tiles were found to be in good agreement with our expectations, and the transparencies were high enough to be used for the RICH radiator.

  1. Synthesis of p-type GaN nanowires.

    Science.gov (United States)

    Kim, Sung Wook; Park, Youn Ho; Kim, Ilsoo; Park, Tae-Eon; Kwon, Byoung Wook; Choi, Won Kook; Choi, Heon-Jin

    2013-09-21

    GaN has been utilized in optoelectronics for two decades. However, p-type doping still remains crucial for realization of high performance GaN optoelectronics. Though Mg has been used as a p-dopant, its efficiency is low due to the formation of Mg-H complexes and/or structural defects in the course of doping. As a potential alternative p-type dopant, Cu has been recognized as an acceptor impurity for GaN. Herein, we report the fabrication of Cu-doped GaN nanowires (Cu:GaN NWs) and their p-type characteristics. The NWs were grown vertically via a vapor-liquid-solid (VLS) mechanism using a Au/Ni catalyst. Electrical characterization using a nanowire-field effect transistor (NW-FET) showed that the NWs exhibited n-type characteristics. However, with further annealing, the NWs showed p-type characteristics. A homo-junction structure (consisting of annealed Cu:GaN NW/n-type GaN thin film) exhibited p-n junction characteristics. A hybrid organic light emitting diode (OLED) employing the annealed Cu:GaN NWs as a hole injection layer (HIL) also demonstrated current injected luminescence. These results suggest that Cu can be used as a p-type dopant for GaN NWs.

  2. Single P-N junction tandem photovoltaic device

    Science.gov (United States)

    Walukiewicz, Wladyslaw [Kensington, CA; Ager, III, Joel W.; Yu, Kin Man [Lafayette, CA

    2011-10-18

    A single P-N junction solar cell is provided having two depletion regions for charge separation while allowing the electrons and holes to recombine such that the voltages associated with both depletion regions of the solar cell will add together. The single p-n junction solar cell includes an alloy of either InGaN or InAlN formed on one side of the P-N junction with Si formed on the other side in order to produce characteristics of a two junction (2J) tandem solar cell through only a single P-N junction. A single P-N junction solar cell having tandem solar cell characteristics will achieve power conversion efficiencies exceeding 30%.

  3. Crate counter for normal operating loss

    International Nuclear Information System (INIS)

    Harlan, R.A.

    A lithium-loaded zinc sulfide scintillation counter to closely assay plutonium in waste packaged in 1.3 by 1.3 by 2.13m crates was built. In addition to assays for normal operating loss accounting, the counter will allow safeguards verification immediately before shipment of the crates for burial. The counter should detect approximately 10 g of plutonium in 1000 kg of waste

  4. An introduction to automatic radioactive sample counters

    International Nuclear Information System (INIS)

    1980-01-01

    The subject is covered in chapters, entitled; the detection of radiation in sample counters; nucleonic equipment; liquid scintillation counting; basic features of automatic sample counters; statistics of counting; data analysis; purchase, installation, calibration and maintenance of automatic sample counters. (U.K.)

  5. Analysis of over-the-counter medicines use among nursing students

    Directory of Open Access Journals (Sweden)

    Mlinar Suzana

    2015-01-01

    Full Text Available Background/Aim. The use of over-the-counter (OTC medication is widespread among the adult and student populations in Slovenia. The aim of the study was to analyse the prevalence of OTC medicines use among nursing students with respect to sociodemographic characteristics. Methods. A total of 241 nursing students in the Faculty of Health Sciences, Ljubljana, were included in the cross-sectional study. A questionnaire was created for the purposes of the study. Statistical analysis was performed with SPSS 20. Descriptive statistics, t-test and the contingency coefficient were calculated. Statistical significance was set at the p-value of < 0.05. Results. The study showed that the use of prescription drugs was significantly higher in women (p = 0.029, students living in rural areas (p = 0.005 and students who described themselves as being of bad health (p = 0.008. At the same time, a third of the respondents had been taking one OTC medicine within the last month; those taking several prescription drugs commonly administered several over-the-counter medicines (p = 0.027. Women used OTC medicines to treat pain and fever (p = 0.001, respiratory issues (p = 0.015, and fungal infections (p < 0.000 more often than men. OTC medicines were also used to treat minor mental health issues by a higher proportion of respondents over 21 years of age (p = 0.005 and women (p < 0.000, while over-the-counter medicines for treating skin conditions were more frequently used in rural areas (p = 0.006. Conclusion. Nursing students tend to use OTC medicines on their own accord, receiving instructions for safe use with their purchase, which points to adequate promotion of safe use of medications in Slovenia. Men's assessment of their personal health tends to be better than that of women, who also use medication more frequently. A connection between poor health and a higher incidence of the use of OTC medicines was established. The use of OTC medicines to treat minor mental

  6. Contribution to the study of πN → π1π2N reactions with creation of an intermediate N*3/2(1236) isobar from 0.4 to 1.5 GeV

    International Nuclear Information System (INIS)

    Merlo, J.P.

    1976-01-01

    The one pion production reaction π + p → π + pπ 0 has been studied up to 1.5 GeV. The π 0 angular distribution measured by counter techniques has been compared to bubble chamber data. Angular distributions are interpreted in the hypothesis of formation of the intermediate N * 3/2 (1236) isobar. Angular distributions for isobar production and decay in one pion production reactions πN → π 1 N * (N * → π 2 N], are calculated in chapter II. π + p → π + pπ 0 experimental results are reported and analyzed in chapter III. An estimation of the pion-isobar partial wave amplitudes in reaction π + p → π 0 N *++ 3/2 (1236) has been tempted. Comparison with π + p phase shift analyses is made. Bubble chamber data for π - p → π - π + n channel are presented at the end of chapter III. (author) [fr

  7. Successive ionic layer adsorption and reaction deposited kesterite Cu2ZnSnS4 nanoflakes counter electrodes for efficient dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Mali, Sawanta S.; Shim, Chang Su; Hong, Chang Kook

    2014-01-01

    Highlights: • Cu 2 ZnSnS 4 nanoflakes by SILAR technique. • Hydrothermal synthesis of TiO 2 . • Counter electrode for DSSC application. • 4.48% conversion efficiency. - Abstract: In this investigation, we have successfully synthesized Cu 2 ZnSnS 4 (CZTS) nanoflakes by successive ionic layer adsorption and reaction (SILAR) method and used as a counter electrode in the hydrothermally grown TiO 2 based dye sensitized solar cells (DSSCs). The prepared CZTS nanoflakes were characterized using X-ray powder diffraction (XRD), field emission scanning electron microscopy (FESEM), micro Raman spectroscopy and energy dispersive analysis. Our DSSCs results revealed that, compared with conventional Pt/FTO counter electrode DSSCs, nanoflakes of p-type CZTS as the photocathode and n-type TiO 2 thin films as the photoanode shows an increased short circuit current (13.35 mA/cm 2 ) with 4.84% power conversion efficiency. The detailed interface properties of were analyzed by electrochemical impedance spectroscopy (EIS) measurements

  8. Measurements of electron attachment by oxygen molecule in proportional counter

    Energy Technology Data Exchange (ETDEWEB)

    Tosaki, M., E-mail: tosaki.mitsuo.3v@kyoto-u.ac.jp [Radioisotope Research Center, Kyoto University, Kyoto 606-8501 (Japan); Kawano, T. [National Institute for Fusion Science, 322-6 Oroshi, Toki 509-5292 (Japan); Isozumi, Y. [Radioisotope Research Center, Kyoto University, Kyoto 606-8501 (Japan)

    2013-11-15

    We present pulse height measurements for 5-keV Auger electrons from a radioactive {sup 55}Fe source mounted at the inner cathode surface of cylindrical proportional counter, which is operated with CH{sub 4} admixed dry air or N{sub 2}. A clear shift of the pulse height has been observed by varying the amount of the admixtures; the number of electrons, created in the primary ionization by Auger electrons, is decreased by the electron attachment of the admixtures during their drift from the place near the source to the anode wire. The large gas amplification (typically 10{sup 4}) in the secondary ionization of proportional counter makes it possible to investigate a small change in the number of primary electrons. The electron attenuation cross-section of O{sub 2} has been evaluated by analyzing the shifts of the pulse height caused by the electron attachment to dry air and N{sub 2}.

  9. The counter ion: expanding excipient functionality

    Directory of Open Access Journals (Sweden)

    Shireesh Apte

    2011-06-01

    Full Text Available Excipients have increasingly become 'enablers' of drug delivery and efficacy rather than passive bystanders. Advances in pharmaceutical technology have enabled the ability to deliver specific counter ions (in the form of the counter ion containing excipient and the API simultaneously to preselected targets in the body. This, coupled with a near universal mechanism of columbic interactions that determine the [API- counter ion] efficacy, can be harnessed to exploit this hitherto unavailable or unrecognized enabling mechanism. New excipients may be assembled by a near inexhaustible supply of different permutations of counter ions and their judicious use in specific situations could potentially drive a renaissance in excipient innovation (and drug delivery and efficacy despite regulatory stagnation.

  10. Counter-cryptanalysis

    NARCIS (Netherlands)

    M.M.J. Stevens (Marc); R. Canetti; J.A. Garay

    2013-01-01

    textabstractWe introduce \\emph{counter-cryptanalysis} as a new paradigm for strengthening weak cryptographic primitives against cryptanalytic attacks. Redesigning a weak primitive to more strongly resist cryptanalytic techniques will unavoidably break backwards compatibility. Instead,

  11. Over-the-counter codeine use in Iceland

    DEFF Research Database (Denmark)

    Almarsdóttir, A B; Grimsson, A

    2000-01-01

    BACKGROUND: The objective of this study was to test the assumption that liberalizing community pharmacy ownership in Iceland would lead to increased irrational use of over-the-counter pain relievers containing codeine. METHODS: Based on this assumption we built and tested a model using an interru......BACKGROUND: The objective of this study was to test the assumption that liberalizing community pharmacy ownership in Iceland would lead to increased irrational use of over-the-counter pain relievers containing codeine. METHODS: Based on this assumption we built and tested a model using...... an interrupted time series design that contrasts the monthly sales data for over-the-counter pain relievers containing codeine before and after the legislation took effect. RESULTS: The total use of over-the-counter pain relievers containing codeine as well as those containing paracetamol and codeine has risen...... leads to irrational use of over-the-counter medicines is not substantiated in the case of over-the-counter pain relievers containing codeine....

  12. Experiments on iron shield transmission of quasi-monoenergetic neutrons generated by 43- and 68-MeV protons via the {sup 7}Li(p,n) reaction

    Energy Technology Data Exchange (ETDEWEB)

    Nakashima, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Tanaka, Shun-ichi; Nakao, Noriaki [and others

    1996-03-01

    In order to provide benchmark data of neutrons transmitted through iron shields in the intermediate-energy region, spatial distributions of neutron energy spectra and reaction rates behind and inside the iron shields of thickness up to 130 cm were measured for 43- and 68-MeVp-{sup 7}Li neutrons using a quasi-monoenergetic neutron beam source at the 90-MV AVF cyclotron facility of the TLARA facility in JAERI. The measured data by five kinds of detectors: the BC501A detector, the Bonner ball counter, {sup 238}U and {sup 232}Th fission counters, {sup 7}LiF and {sup nat}LiF TLDs and solid state nuclear track detector, are numerically provided in this report in the energy region between 10{sup -4} eV and the energy of peak neutrons generated by the {sup 7}Li(p,n) reaction. (author).

  13. Effect of four over-the-counter tooth-whitening products on enamel microhardness.

    Science.gov (United States)

    Majeed, A; Grobler, S R; Moola, M H; Oberholzer, T G

    2011-10-01

    This in vitro study evaluated the effect of four over-the-counter tooth-whitening products on enamel microhardness. Fifty enamel blocks were prepared from extracted human molar teeth. The enamel surfaces were polished up to 1200 grit fineness and the specimens randomly divided into five groups. Enamel blocks were exposed to: Rapid White (n=10); Absolute White (n=10); Speed White (n=10) and White Glo (n=10) whitening products, according to the manufacturers' instructions. As control, ten enamel blocks were kept in artificial saliva at 37 degrees C without any treatment. Microhardness values were obtained before exposure (baseline) and after 1, 7 and 14-day treatment periods using a digital hardness tester with a Vickers diamond indenter. Data were analysed using Wilcoxon Signed Rank Sum Test, one-way ANOVA and Tukey-Kramer Multiple Comparison Test (penamel microhardness. Speed White increased the microhardness of enamel, while White Glo and artificial saliva had no effect on hardness. Over-the-counter tooth-whitening products might decrease enamel microhardness depending on the type of product.

  14. Cross sections for the (n,p), (n,α) and (n,2n) threshold reactions

    International Nuclear Information System (INIS)

    Bychkov, V.M.; Manokhin, V.N.; Pashchenko, A.B.; Plyaskin, V.I.

    1980-07-01

    The (n,p), (n,α), (n,2n) threshold reactions are reviewed for nuclei with Z>=20 in the neutron energy range from the threshold up to 20MeV. The review consists of four parts. In the first part the theoretical methods of cross-section calculations and the empirical or semi-empirical systematics are considered. In the second, third and fourth parts the experimental data compilations on the (n,p), (n,α) and (n,2n) excitation functions are given. The recommended values of cross-sections at 14.5MeV neutron energy are given in tables. For some isotopes the recommended curves of excitation functions also are given in graphs. (author)

  15. Optoelectronic properties of p-diamond/n-GaN nanowire heterojunctions

    International Nuclear Information System (INIS)

    Schuster, Fabian; Hetzl, Martin; Weiszer, Saskia; Garrido, Jose A.; Stutzmann, Martin; Wolfer, Marco; Nebel, Christoph E.; Kato, Hiromitsu

    2015-01-01

    In this work, nanodiodes comprised of n-GaN nanowires on p-diamond substrates are investigated. The electric transport properties are discussed on the basis of simulations and determined experimentally for individual p-diamond/n-GaN nanodiodes by applying conductive atomic force microscopy. For low doping concentrations, a high rectification ratio is observed. The fabrication of a prototype nanoLED device on the basis of ensemble nanowire contacts is presented, showing simultaneous electroluminescence in the UV and the green spectral range which can be ascribed to hole injection into the n-GaN nanowires and electron injection into the p-diamond, respectively. In addition, the operation and heat distribution of the nanoLED device are visualized by active thermographic imaging

  16. Basic Research Needs for Countering Terrorism

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, W.; Michalske, T.; Trewhella, J.; Makowski, L.; Swanson, B.; Colson, S.; Hazen, T.; Roberto, F.; Franz, D.; Resnick, G.; Jacobson, S.; Valdez, J.; Gourley, P.; Tadros, M.; Sigman, M.; Sailor, M.; Ramsey, M.; Smith, B.; Shea, K.; Hrbek, J.; Rodacy, P.; Tevault, D.; Edelstein, N.; Beitz, J.; Burns, C.; Choppin, G.; Clark, S.; Dietz, M.; Rogers, R.; Traina, S.; Baldwin, D.; Thurnauer, M.; Hall, G.; Newman, L.; Miller, D.; Kung, H.; Parkin, D.; Shuh, D.; Shaw, H.; Terminello, L.; Meisel, D.; Blake, D.; Buchanan, M.; Roberto, J.; Colson, S.; Carling, R.; Samara, G.; Sasaki, D.; Pianetta, P.; Faison, B.; Thomassen, D.; Fryberger, T.; Kiernan, G.; Kreisler, M.; Morgan, L.; Hicks, J.; Dehmer, J.; Kerr, L.; Smith, B.; Mays, J.; Clark, S.

    2002-03-01

    To identify connections between technology needs for countering terrorism and underlying science issues and to recommend investment strategies to increase the impact of basic research on efforts to counter terrorism.

  17. Direct measurement of gaseous activities by diffusion-in long proportional counter method

    International Nuclear Information System (INIS)

    Yoshida, M.; Yamamoto, T.; Wu, Y.; Aratani, T.; Uritani, A.; Mori, C.

    1993-01-01

    Direct measurement of gaseous activities by the diffusion-in long proportional counter method (DLPC method) was studied. The measuring time without end effect was estimated by observing the behavior of 37 Ar in the counter and was long enough to carry out the accurate activity measurement. The correction for wall effect was also examined on the basis of the measured and calculated correction factors. Among the tested gases of methane, P10 gas and propane, P10 gas was made clear to be a suitable counting gas for the DLPC method because of good diffusion properties and small wall effect. This method is quite effective for standardization of gaseous activities used for tracer experiments and calibration works of radioactive gas monitoring instruments. (orig.)

  18. Sorption of Eu(III) at feldspar/water interface. Effects of pH, organic matter, counter ions, and temperature

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ping; Liang, Jianjun; Fan, Qiaohui [Chinese Academy of Sciences, Lanzhou (China). Key Lab. of Petroleum Resources Research; Wu, Hanyu [Chinese Academy of Sciences, Lanzhou (China). Key Lab. of Petroleum Resources Research; Lanzhou Univ. (China). Radiochemistry Lab.; Yin, Zhuoxin; Pan, Duoqiang; Wu, Wangsuo [Lanzhou Univ. (China). Radiochemistry Lab.; Xu, Di [Chinese Academy of Sciences, Nanjing (China). State Key Lab. of Lake Science and Environment

    2017-07-01

    The sorption of Eu(III) on potassium feldspar (K-feldspar) was studied under various physicochemical conditions such as pH, temperature, counter ions and organic matter. The results showed that the sorption of Eu(III) on K-feldspar significantly increased with the increase of pH, and high Eu(III) concentration can inhibit such immobility to some extent. The presence of humic acid (HA) can increase the sorption of Eu(III) on K-feldspar in low pH range; while inhibit to a large extent under alkaline conditions. It is very interesting that at pH ∝6.5, high ionic strength can promote the sorption of Eu(III) on K-feldspar in the presence of HA. In contrast, Eu(III) sorption was restricted obviously by NaCl in the absence of HA. The sorption procedure was involved with ion exchange and/or outer-sphere complexation as well as inner-sphere complexation. The presence of F{sup -} and PO{sub 4}{sup 3-} dramatically enhanced Eu(III) sorption on K-feldspar, whereas both SO{sub 4}{sup 2-} and CO{sub 3}{sup 2-} had negative effects on Eu(III) sorption. X-ray photoelectron spectroscopy analysis indicated that Eu(III) tended to form hydrolysates at high initial concentration (3 x 10{sup -4} mol/L) and high temperature (338 K).

  19. A fast photo-counter with multi-level buffers

    International Nuclear Information System (INIS)

    Peng Hu; Zhou Peiling; Yao Kun; Guo Guangcan

    1992-01-01

    Digital Photon Correlator (DPC) is composed of a Photo-counter and a data processing unit. The performance of Photo-counter in data acquisition system has a direct influence on data processing. The Photo-counter with fast carry designed here has multi-level buffers. Photon pulses can be correctly and dynamically recorded by the Photo-counter and processed by a single chip computer

  20. Preparative separation of C19-diterpenoid alkaloids from Aconitum carmichaelii Debx by pH‑zone-refining counter-current chromatography

    Directory of Open Access Journals (Sweden)

    Dahui Liu

    2013-01-01

    Full Text Available The technique of pH-zone-refining counter-current chromatography was successfully applied to preparatively separate three C19-diterpenoid alkaloids from the crude extracts of Aconitum carmichaelii for the first time using a two-phase solvent system of petroleum ether-ethyl acetate-methanol-water (5:5:1:9, v/v/v/v. Mesaconitine (I, hypaconitine (II, and deoxyaconitine (III were obtained from 2.5 g of the crude alkaloids in a one-step separation; the yields were 4.16%, 16.96%, and 5.05%, respectively. The purities of compounds I, II, and III were 93.0%, 95%, and 96%, respectively, as determined by HPLC. The chemical structures of the three compounds were identified by electrospray ionization mass spectrometry (ESI-MS and NMR.

  1. Garvey-Kelson mass relations and n-p interaction

    International Nuclear Information System (INIS)

    Gao Zaochun; Meng Jie; Chen Yongshou

    2001-01-01

    Two Garvey-Kelson mass relations are found to be directly related to the n-p interaction. In the case of the same nuclear core, the neutron-proton interaction energy between two neutrons and one proton ε 2n-1p is experimentally found to be close to that between one neutron and two protons ε 1n-2p , which is equivalent to the first Garvey-Kelson mass relation. The sum of ε 2n-1p and ε 1n-2p is close to the n-p interaction energy between two neutrons and two protons ε 2n-2p , which leads to the second Garvey-Kelson mass relation. An explanation of these two n-p interaction relations is presented. It is shown that both of these mass relations hold more accurately when the core is an even-even core

  2. Counter-responses as organizers in adolescent analysis and therapy.

    Science.gov (United States)

    Richmond, M Barrie

    2004-01-01

    The author introduces Counter-response as a phenomological term to replace theory-burdened terms like counter-transference, counter-identification, and counter-resistance. He discusses the analyst's use of self (drawing on the comparison with Winnicott's use of the object) in processing the expectable destabilizing counter-reactions that occur in working therapeutically with disturbed adolescents and their parents. Further; he discusses the counter-reaction to the patient's narrative, acting-out, and how re-enactments can serve as an organizer for understanding the patient's inner life when the analyst formulates his/her counter-response. Emphasis is placed on the therapist forming his or her own narrative with the adolescent that takes into account the evoked counter-reaction. For this purpose, the author recommends the use of a combined counter-response and metaphor-orienting perspective to acknowledge and work with the denial, illusions, reversal of perspective, and catastrophic anxieties experienced with these adolescents. The counter-response perspective permits the emergence of the disturbed adolescent's novel narrative; however, since these experiences can be destabilizing or disruptive, the author also recommends the use of a personal metaphor to anticipate the reluctance to examining, processing, and formulating the analyst's dysphoric counter-reaction. With the use of the counter-response, the analyst's therapeutic ideal is to achieve a more optimal balance between using accepted narrative theories and exploring novel enactment experiences. His swimming metaphor stratagem is designed to keep the analyst in these difficult encounters.

  3. Hypernuclear weak decay experiments at KEK: n-n and n-p coincidence measurement

    International Nuclear Information System (INIS)

    Outa, H.; Ajimura, S.; Aoki, K.; Banu, A.; Bhang, H.C.; Fukuda, T.; Hashimoto, O.; Hwang, J.I.; Kameoka, S.; Kang, B.H.; Kim, E.H.; Kim, J.H.; Kim, M.J.; Maruta, T.; Miura, Y.; Miyake, Y.; Nagae, T.; Nakamura, M.; Nakamura, S.N.; Noumi, H.; Okada, S.; Okayasu, Y.; Park, H.; Saha, P.K.; Sato, Y.; Sekimoto, M.; Takahashi, T.; Tamura, H.; Tanida, K.; Toyoda, A.; Tsukada, K.; Watanabe, T.; Yim, H.J.

    2005-01-01

    We performed a coincidence measurement of two nucleons emitted from the nonmesonic weak decay (NMWD) of 5 Λ He and 12 Λ C formed via the (π+,K+) reaction. In both of n+p and n+n pair coincidence spectra, we observed a clean back-to-back correlation coming from the two-body decay of Λp->np and Λn->nn, respectively. We obtained the ratio of the nucleon pair numbers, Nnn/Nnp ( 5 Λ He)=0.45-bar +/--bar 0.11-bar (stat)-bar +/--bar 0.03-bar (syst) in the kinematic region of cosθNN-0.8. Since each decay mode was exclusively detected, the measured ratio should be close to the ratio of Γ(Λp->nn)/Γ(Λn->np). The Γn/Γp ratio was measured also for the NMWD of 12 Λ C. It is also close to 0.5. Those ratios are consistent with recent theoretical calculations based on the heavy meson/direct quark exchange picture

  4. High-speed parallel counter

    International Nuclear Information System (INIS)

    Gus'kov, B.N.; Kalinnikov, V.A.; Krastev, V.R.; Maksimov, A.N.; Nikityuk, N.M.

    1985-01-01

    This paper describes a high-speed parallel counter that contains 31 inputs and 15 outputs and is implemented by integrated circuits of series 500. The counter is designed for fast sampling of events according to the number of particles that pass simultaneously through the hodoscopic plane of the detector. The minimum delay of the output signals relative to the input is 43 nsec. The duration of the output signals can be varied from 75 to 120 nsec

  5. Feasibility studies of high-pressure 4π proportional counter for absolute activity measurement

    International Nuclear Information System (INIS)

    Hino, Y.; Kawada, Y.

    1988-01-01

    A high-pressure proportional counter system is constructed. The high pressure 4πβ counter system constructed is made of aluminum and is divided into two 2π counters. The gas pressure is controlled with a pressure regulator and very fine leak valves to keep the balance of a stable pressure and constant flow rate. Investigation of characteristics of th counter shows that there is an almost linear relation between voltage and pressure. The linearlity of gas gain of this counter to the electron energies is measured with different gas pressures. Quite good linear gas multiplication is obtained at 0.9 MPa. Another investigation is made of application of to activity measurement of 109 Cd. When the gas pressure is over 0.5 MPa, the proportion of collected conversion electrons to absolute activity comes to a constant value of 96 %. This is quite good agreement with the decay data of 96.4 % conversion electron emission rate. The study indicated many excellent features for activity measurement. Especially the efficiency variation technique is good for automatic data acquisition with a programmable high voltage supplier. Moreover, since it is possible to obtain absolute activity with only one sample, it will be quite useful for limited samples experiments. (N.K.)

  6. Evaluation excitation functions for "2"8Si(n,p)"2"8Al, "3"1P(n,p)"3"1Si, and "1"1"3In(n,γ)"1"1"4"mIn reactions

    International Nuclear Information System (INIS)

    Zolotarev, K.I.

    2014-10-01

    Cross section data for "2"8Si(n,p)"2"8Al, "3"1P(n,p)"3"1Si and "1"1"3In(n,γ)"1"1"4"mIn reactions are needed for solving a wide spectrum of scientific and technical tasks. The excitation function of "2"8Si(n,p)"2"8Al reaction refers to the nuclear data involved in fusion reactor design calculations. The "2"8Si(n,p)"2"8Al reaction is interesting also as the monitor reaction for measurements at fusion facilities. Activation detectors on the basis of the 31P(n,p)31Si reaction are commonly used in the reactor dosimetry. The "1"1"3In(n,γ)"1"1"4"mIn reaction is promising regarding reactor dosimetry application for two reasons. First, due to the "1"1"4"mIn decay parameters which are rather suitable for activation measurements. Half-life of "1"1"4"mIn is equal to T_1/_2 = (49.51 ± 0.01) days and gamma spectrum accompanying decay has only one line with energy 190.27 keV and intensity (15.56 ± 0.15)%. Second, the "1"1"3In(n,γ)"1"1"4"mIn reaction rate may be measured by using one activation detector simultaneously with the "1"1"5In(n,γ)"1"1"6"mIn reaction. Preliminary analysis of existing evaluated excitation functions for "2"8Si(n,p)"2"8Al, "3"1P(n,p)"3"1Si and "1"1"3In(n,γ)"1"1"4"mIn reactions show that new evaluations are needed for all above mentioned reactions. This report is devoted to the preparation of the new evaluations of cross sections data and related covariance matrixes of uncertainties for the "2"8Si(n,p)"2"8Al, "3"1P(n,p)"3"1Si and "1"1"3In(n,γ)"1"1"4"mIn reactions.

  7. N/sub p/.N/sub n/ systematics and their implications

    International Nuclear Information System (INIS)

    Casten, R.F.

    1985-01-01

    A substantial simplification of the systematics in nuclear phase transition regions is obtained if the data are plotted against the product, N/sub p/.N/sub n/, of the number of valence protons and neutrons instead of against N, Z, or A as is usually done. Such a scheme leads to a unified view of nuclear transition regions and to a simplified scheme for collective model calculations. 7 refs., 5 figs

  8. The Micro Trench Gas Counter

    International Nuclear Information System (INIS)

    Schmitz, J.

    1991-07-01

    A novel design is presented for a gas avalanche chamber with micro-strip gas readout. While existing gaseous microstrip detectors (Micro-strip Gas Counters, Knife edge chambers) have a minimum anode pitch of the order of 100 μm, the pitch of the discussed Micro Trench Gas Counter goes down to 30-50 μm. This leads to a better position resolution and two track separation, and a higher radiation resistivity. Its efficiency and signal speed are expected to be the same as the Microstrip Gas Counter. The energy resolution of the device is expected to be equal to or better than 10 percent for the 55 Fe peak. Since the anode strip dimensions are larger than those in a MSGC, the device may be not as sensitive to discharges and mechanical damage. In this report production of the device is briefly described, and predictions on its operation are made based on electric field calculations and experience with the Microstrip Gas Counter. The authors restrict themselves to the application in High Energy Physics. (author). 10 refs.; 9 figs

  9. The 'miniskirt' counter array at CDF II

    International Nuclear Information System (INIS)

    Artikov, A.; Budagov, Yu.; Bellettini, G.

    2002-01-01

    Muon detection is fundamental to many of the interesting analyses at CDF II. For more efficient muon registration in Run II it was decided to increase geometrical coverage. The so-called 'miniskirt' counters are part of this upgrade. The original design parameters of the 'miniskirt' and mixed 'miniskirt' scintillation counters for the CDF Muon System are presented. The modifications, testing and installation of these counters within the CDF Upgrade Project are described in detail. The timing characteristics of mixed 'miniskirt' counters are also investigated using cosmic muons. The measurements show that the time resolution does not exceed 2.2 ns

  10. Scintillation counter and wire chamber front end modules for high energy physics experiments

    International Nuclear Information System (INIS)

    Baldin, Boris; DalMonte, Lou

    2011-01-01

    This document describes two front-end modules developed for the proposed MIPP upgrade (P-960) experiment at Fermilab. The scintillation counter module was developed for the Plastic Ball detector time and charge measurements. The module has eight LEMO 00 input connectors terminated with 50 ohms and accepts negative photomultiplier signals in the range 0.25...1000 pC with the maximum input voltage of 4.0 V. Each input has a passive splitter with integration and differentiation times of ∼20 ns. The integrated portion of the signal is digitized at 26.55 MHz by Analog Devices AD9229 12-bit pipelined 4-channel ADC. The differentiated signal is discriminated for time measurement and sent to one of the four TMC304 inputs. The 4-channel TMC304 chip allows high precision time measurement of rising and falling edges with ∼100 ps resolution and has internal digital pipeline. The ADC data is also pipelined which allows deadtime-less operation with trigger decision times of ∼4 (micro)s. The wire chamber module was developed for MIPP EMCal detector charge measurements. The 32-channel digitizer accepts differential analog signals from four 8-channel integrating wire amplifiers. The connection between wire amplifier and digitizer is provided via 26-wire twist-n-flat cable. The wire amplifier integrates input wire current and has sensitivity of 275 mV/pC and the noise level of ∼0.013 pC. The digitizer uses the same 12-bit AD9229 ADC chip as the scintillator counter module. The wire amplifier has a built-in test pulser with a mask register to provide testing of the individual channels. Both modules are implemented as a 6Ux220 mm VME size board with 48-pin power connector. A custom europack (VME) 21-slot crate is developed for housing these front-end modules.

  11. Measurement of the $\\bar{p}p \\rightarrow \\bar{n}n$ Charge-Exchange Differential Cross-Section

    CERN Multimedia

    2002-01-01

    The aim of this proposal is a measurement of the differential cross-section of the $\\bar{p}$p $\\rightarrow$ $\\bar{n}$n charge-exchange reaction with a point-to-point precision of 1\\% in the forward direction, and an absolute normalization error of 3\\%. The high precision of the data should allow, inter alia, a determination of the $\\pi$NN coupling constant to better than 2\\%.\\\\ \\\\ The measurement will be done using the existing neutron and antineutron detectors built for experiment PS199 and liquid hydrogen target. In one week of running time, with a $\\bar{p}$ beam intensity of 3 $ 10 ^{5} $ $\\bar{p}$/sec, the reaction will be measured at a few $\\bar{p}$ momenta, in the range 500 to 900~MeV/c.

  12. Investigation of the Pulse Height Distribution of Boron Trifluoride Proportional Counters

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Malmskog, S

    1962-08-15

    The report describes a theoretical and experimental investigation of the factors that determine the pulse height distribution of BF{sub 3}, proportional counters irradiated by thermal neutrons. The branching ratio of the {sup 10}B (n,{alpha}) {sup 7}Li reaction for thermal neutrons has been measured.

  13. Assessing the relationship between pharmacists' job satisfaction and over-the-counter counselling at community pharmacies.

    Science.gov (United States)

    Urbonas, Gvidas; Kubilienė, Loreta

    2016-04-01

    Community pharmacies have an increasing role in self-medication and community health is dependent on the quality of counselling services provided to patients. Some studies show that pharmacists' job satisfaction affects their work quality; other studies found that higher involvement in clinical services increases pharmacists' job satisfaction. To test the relationship between job satisfaction and over-the-counter counselling practice at community pharmacies. Community pharmacies in Lithuania. A convenience sample (n = 305) of community pharmacists participated in the cross-sectional survey where they expressed satisfaction with job and reported on their over-the-counter counselling behaviour on self-report scales. The Partial Least Squares Structural Equation Modelling approach was employed for data analysis. The strength of the relationship between job satisfaction and over-the-counter counselling service. A bidirectional relationship between job satisfaction and over-the-counter counselling service was found. In addition, job satisfaction and over-the-counter counselling quality depended on pharmacists' age. Organizations were recommended to create a counselling friendly environment that would increase pharmacists' job satisfaction and, in return, counselling quality. Also, additional motivation of the retired pharmacists, as well as development of counselling skills of the younger pharmacy workforce, were seen as a means to improve both organizational climate and counselling quality over the counter.

  14. Position-sensitive proportional counter

    International Nuclear Information System (INIS)

    Kopp, M.K.

    1980-01-01

    A position-sensitive proportional counter circuit uses a conventional (low-resistance, metal-wire anode) counter for spatial resolution of an ionizing event along the anode, which functions as an RC line. A pair of preamplifiers at the anode ends act as stabilized active-capacitance loads, each comprising a series-feedback, low-noise amplifier and a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at the anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction of handling of the anodes, and stabilizes the anode resistivity at high count rates (>10 6 counts/sec). (author)

  15. Counter-diabatic driving for Dirac dynamics

    Science.gov (United States)

    Fan, Qi-Zhen; Cheng, Xiao-Hang; Chen, Xi

    2018-03-01

    In this paper, we investigate the fast quantum control of Dirac equation dynamics by counter-diabatic driving, sharing the concept of shortcut to adiabaticity. We systematically calculate the counter-diabatic terms in different Dirac systems, like graphene and trapped ions. Specially, the fast and robust population inversion processes are achieved in Dirac system, taking into account the quantum simulation with trapped ions. In addition, the population transfer between two bands can be suppressed by counter-diabatic driving in graphene system, which might have potential applications in opt-electric devices.

  16. Counter traction makes endoscopic submucosal dissection easier.

    Science.gov (United States)

    Oyama, Tsuneo

    2012-11-01

    Poor counter traction and poor field of vision make endoscopic submucosal dissection (ESD) difficult. Good counter traction allows dissections to be performed more quickly and safely. Position change, which utilizes gravity, is the simplest method to create a clear field of vision. It is useful especially for esophageal and colon ESD. The second easiest method is clip with line method. Counter traction made by clip with line accomplishes the creation of a clear field of vision and suitable counter traction thereby making ESD more efficient and safe. The author published this method in 2002. The name ESD was not established in those days; the name cutting endoscopic mucosal resection (EMR) or EMR with hook knife was used. The other traction methods such as external grasping forceps, internal traction, double channel scope, and double scopes method are introduced in this paper. A good strategy for creating counter traction makes ESD easier.

  17. An efficient anticoincidence counter

    CERN Multimedia

    1977-01-01

    This scintillation counter (about 25 cm diameter) was prepared at CERN for an experiment at the Saclay 600 MeV electron linac studying molecular processes originated in liquid hydrogen by muons. The counter is meant to surround the target and detect charged particles emerging from the hydrogen. The experiment was a CERN-Saclay collaboration which used the linac so as to take advantage of the time structure of the electron beam(see CERN Courier Sep 1977 and J. Bardin et al. Phys. Lett. B104 (1981) 320)

  18. Antipruritic Effect of Cold-induced and Transient Receptor Potential-agonist-induced Counter-irritation on Histaminergic Itch in Humans

    DEFF Research Database (Denmark)

    Andersen, Hjalte H.; Melholt, Camilla; Hilborg, Sigurd D.

    2017-01-01

    A frequent empirical observation is that cold-induced counter-irritation may attenuate itch. The aim of this randomized, single-blinded, exploratory study was to evaluate the counter-irritation effects of cold-stimulation and topical application of transient receptor potential TRPA1/M8-agonists...... and trans-cinnamaldehyde had antipruritic efficacy similar to doxepin (p Cold-induced counter-irritation had an inhibitory effect on histaminergic itch, suggesting that agonists of cold transduction receptors could be of potential antipruritic value....... (measured by laser-speckle perfusion-imaging). Homotopic thermal counter-irritation was performed with 6 temperatures, ranging from 4°C to 37°C, using a 3 × 3-cm thermal stimulator. Chemical “cold-like” counter-irritation was conducted with 40% L-menthol and 10% trans-cinnamaldehyde, while 5% doxepin...

  19. COUNTER-PUNISHMENT, COMMUNICATION AND COOPERATION AMONG PARTNERS

    Directory of Open Access Journals (Sweden)

    Giulia eAndrighetto

    2016-04-01

    Full Text Available We study how communication affects cooperation in an experimental public goods environment with punishment and counter-punishment opportunities. Participants interacted over thirty rounds in fixed groups with fixed identifiers that allowed them to trace other group members’ behavior over time. The two dimensions of communication we study are asking for a specific contribution level and having to express oneself when choosing to counter-punish. We conduct four experimental treatments, all involving a contribution stage, a punishment stage and a counter-punishment stage in each round. In the first treatment communication is not possible at any of the stages. The second treatment allows participants to ask for a contribution level at the punishment stage and in the third treatment participants are required to send a message if they decide to counter-punishment. The fourth combines the two communication channels of the second and third treatments. We find that the three treatments involving communication at any of the two relevant stages lead to significantly higher contributions than the baseline treatment. We find no difference between the three treatments with communication. We also relate our results to previous results from treatments without counter-punishment opportunities and do not find that the presence of counter-punishment leads to lower cooperation level. The overall pattern of results shows that given fixed identifiers the key factor is the presence of communication. Whenever communication is possible contributions and earnings are higher than when it is not, regardless of counter-punishment opportunities.

  20. "Puuttuva palanen" : kristillinen päihdehoito päihdeasiakkaan näkökulmasta

    OpenAIRE

    Nygård, Sari

    2008-01-01

    Suomessa kristillinen päihdehoito on saamassa yhä enemmän jalansijaa suomalaisessa päihdepalvelujärjestelmässä. Kysyntä laadukkaasta päihdehoidosta kasvaa ja tämän takia on tärkeää saada tutkittua tietoa aiheesta. Kristillisestä päihdehoidosta tutkimusta on tehty melko vähän verrattuna tavanomaiseen päihdehoitotyöhön. Opinnäytetyö on tehty Hoitokoti Seukkalaan, joka hoitaa mielenterveys- ja päihdeongelmista kärsiviä ihmisiä kristillisiä periaatteita kunnioittaen. Opinnäytetyön tehtävänä on se...

  1. Consumer Preferences for High Welfare Meat in Germany: Self-service Counter or Service Counter?

    Directory of Open Access Journals (Sweden)

    Ramona Weinrich

    2015-01-01

    Full Text Available Many people view animal welfare standards in the agricultural industry as critical and some consumers would prefer to buy high welfare meat. In order to successfully introduce high welfare meat products onto the market, some important marketing decisions must be made. Due to limited shelf space in retail outlets, niche products like high welfare meat cannot be placed both at the self-service counter and at the service counter. In order to analyze where to place it best an online survey of 642 German consumers was conducted. By means of factor and cluster analyses, consumers’ animal welfare attitudes and their preference for a point of purchase were combined. The different target groups were joint using cross tabulation analysis. The results reveal that consumers in the target group show a more positive attitude to the service counter.

  2. Electromagnetically induced guiding and superradiant amplification of counter-propagating lasers in plasma

    International Nuclear Information System (INIS)

    Shvets, G.; Fisch, N.J.; Pukhov, A.

    1999-01-01

    The interaction of counter-propagating laser pulses in a plasma is considered. When the frequencies of the two lasers are close, nonlinear modification of the refraction index results in the mutual focusing of the two beams. A short (of order the plasma period) laser pulse can be nonlinearly focused by a long counter-propagating beam which extends over the entire guiding length. It is also demonstrated that a short ( p ) laser pulse can be superradiantly amplified by a counter-propagating long low-intensity pump while remaining ultra-short. Particle-in-Cell simulations indicate that pump depletion can be as high as 40%. This implies that the long pump is efficiently compressed in time without frequency chirping and pulse stretching, making the superradiant amplification an interesting alternative to the conventional method of producing ultra-intense pulses by the chirped-pulse amplification. copyright 1999 American Institute of Physics

  3. P N Kotru

    Indian Academy of Sciences (India)

    Volume 33 Issue 4 August 2010 pp 377-382 Electrical Properties. Dielectric and thermal studies on gel grown strontium tartrate pentahydrate crystals ... High resolution X-ray diffraction studies on unirradiated and irradiated strontium hexaferrite crystals · Balwinder Kaur Monita Bhat F Licci Ravi Kumar K K Bamzai P N Kotru.

  4. 21 CFR 866.2170 - Automated colony counter.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2170 Automated colony counter. (a) Identification. An automated colony counter is a mechanical device intended for medical...

  5. A consistent analysis of (p,p`) and (n,n`) reactions using the Feshbach-Kerman-Koonin model

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioka, S.; Watanabe, Y.; Harada, M. [Kyushu Univ., Fukuoka (Japan)] [and others

    1997-03-01

    Double-differential proton emission cross sections were measured for proton-induced reactions on several medium-heavy nuclei ({sup 54,56}Fe, {sup 60}Ni, {sup 90}Zr, and {sup 93}Nb) at two incident energies of 14.1 and 26 MeV. The (p,p`) data for {sup 56}Fe and {sup 93}Nb were compared with available data of (n,n`) scattering for the same target nuclei and incident energies, and both data were analyzed using the Feshbach-Kerman-Koonin model to extract the strength V{sub 0} of the effective N-N interaction which is the only free parameter used in multistep direct calculations. (author)

  6. Simulation studies of the n{sup +}n{sup -} Si sensors having p-spray/p-stop implant for the SiD experiment

    Energy Technology Data Exchange (ETDEWEB)

    Saxena, Pooja; Ranjan, Kirti [Centre for Detector and Related Software Technology, Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Bhardwaj, Ashutosh, E-mail: abhardwaj@physics.du.ac.in [Centre for Detector and Related Software Technology, Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Shivpuri, R.K.; Bhattacharya, Satyaki [Centre for Detector and Related Software Technology, Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India)

    2011-12-01

    Silicon Detector (SiD) is one of the proposed detectors for the future International Linear Collider (ILC). In the innermost vertex of the ILC, Si micro-strip sensors will be exposed to the neutron background of around 1-1.6 Multiplication-Sign 10{sup 10} 1 MeV equivalent neutrons cm{sup -2} year{sup -1}. The p{sup +}n{sup -}n{sup +} double-sided Si strip sensors are supposed to be used as position sensitive sensors for SiD. The shortening due to electron accumulation on the n{sup +}n{sup -} side of these sensors leads to uniform spreading of signal over all the n{sup +} strips and thus ensuring good isolation between the n{sup +} strips becomes one of the major issues in these sensors. One of the possible solutions is the use of floating p-type implants introduced between the n{sup +} strips (p-stops) and another alternative is the use of uniform layer of p-type implant on the entire n-side (p-spray). However, pre-breakdown micro-discharge is reported because of the high electric field at the edge of the p-stop/p-spray. An optimization of the implant dose profile of the p-stop and p-spray is required to achieve good electrical isolation while ensuring satisfactory breakdown performance of the Si sensors. Preliminary results of the simulation study performed on the n{sup +}n{sup -} Si sensors having p-stop and p-spray using device simulation program, ATLAS, are presented.

  7. Preparative separation of C{sub 19}-diterpenoid alkaloids from Aconitum carmichaelii Debx by pH zone-refining counter-current chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Dahui [Institute of Medicinal Plants, Yunnan Academy of Agricultural Sciences, Kunming (China); Shu, Xikai; Wang, Xiao; Fang, Lei; Huang, Luqi, E-mail: wxjn1998@126.com [Shandong Analysis and Test Center, Shandong Academy of Sciences, Jinan, Shandong (China); Xi, Xingjun; Zheng, Zhenjia [China National institute of Standardization, Beijing (China)

    2013-11-01

    The technique of pH-zone-refining counter-current chromatography was successfully applied to preparatively separate three C{sub 19}-diterpenoid alkaloids from the crude extracts of Aconitum carmichaelii for the first time using a two-phase solvent system of petroleum ether-ethyl acetate-methanol-water (5:5:1:9, v/v/v/v). Mesaconitine (I), hypaconitine (II), and deoxyaconitine (III) were obtained from 2.5 g of the crude alkaloids in a one-step separation; the yields were 4.16%, 16.96%, and 5.05%, respectively. The purities of compounds I, II, and III were 93.0%, 95%, and 96%, respectively, as determined by HPLC. The chemical structures of the three compounds were identified by electrospray ionization mass spectrometry (ESI-MS) and NMR. (author)

  8. Characterization of an Mg-implanted GaN p-i-n Diode

    Science.gov (United States)

    2016-03-31

    Characterization of an Mg- implanted GaN p-i-n Diode Travis J. Anderson, Jordan D. Greenlee, Boris N. Feigelson, Karl D. Hobart, and Francis J...Kub Naval Research Laboratory, Washington, DC 20375 Abstract: A p-i-n diode formed by the implantation of Mg in GaN was fabricated and...characterized. After implantation , Mg was activated using the symmetrical multicycle rapid thermal annealing technique with heating pulses up to 1340C

  9. Silicon fiber with p-n junction

    International Nuclear Information System (INIS)

    Homa, D.; Cito, A.; Pickrell, G.; Hill, C.; Scott, B.

    2014-01-01

    In this study, we fabricated a p-n junction in a fiber with a phosphorous doped silicon core and fused silica cladding. The fibers were fabricated via a hybrid process of the core-suction and melt-draw techniques and maintained overall diameters ranging from 200 to 900 μm and core diameters of 20–800 μm. The p-n junction was formed by doping the fiber with boron and confirmed via the current-voltage characteristic. The demonstration of a p-n junction in a melt-drawn silicon core fiber paves the way for the seamless integration of optical and electronic devices in fibers.

  10. Radiation resistance and comparative performance of ITO/InP and n/p InP homojunction solar cells

    International Nuclear Information System (INIS)

    Weinberg, I.; Swartz, C.K.; Hart, R.E. Jr.; Coutts, T.J.

    1988-09-01

    The radiation resistance of ITO/InP cells processed by DC magnetron sputtering is compared to that of standard n/p InP and GaAs homojunction cells. After 20 MeV proton irradiations, it is found that the radiation resistance of the present ITO/InP cell is comparable to that of the n/p homojunction InP cell and that both InP cell types have radiation resistance significantly greater than GaAs. The relatively lower radiation resistance, observed at higher fluence, for the InP cell with the deepest junction depth, is attributed to losses in the cells emitter region. Diode parameters obtained from I sub sc - V sub oc plots, data from surface Raman spectroscopy, and determinations of surface conductivity types are used to investigate the configuration of the ITO/InP cells. It is concluded that thesee latter cells are n/p homojunctions, the n-region consisting of a disordered layer at the oxide semiconductor

  11. Development of photocathodes for gas counters

    International Nuclear Information System (INIS)

    Chalot, J.F.

    1982-03-01

    A lot of ways of physics needs the development of high sensibility imaging devices with large sensitive surface. The problems brought by the building of such devices may be solved by the use of gaz counters. But we must sensitize these counters to low energy photons ( [fr

  12. Does the delta quench Gamow-Teller strength in (p,n)- and (p vector,p vector')-reactions

    International Nuclear Information System (INIS)

    Osterfeld, F.; Schulte, A.; Udagawa, T.; Yabe, M.

    1986-01-01

    Microscopic analyses of complete forward angle intermediate energy (p,n)-, ( 3 He,t)- and (p vector,p vector')-spin-flip spectra are presented for the reactions 90 Zr(p,n), 90 Zr( 3 He,t) and 90 Zr(p vector,p vector'). It is shown that the whole spectra up to high excitation energies (E X ∝50 MeV) are the result of correlated one-particle-one-hole (1p1h) spin-isospin transitions only. The spectra reflect, therefore, the linear spin-isospin response of the target nucleus to the probing external hadronic fields. Our results suggest that the measured (p,n)-, ( 3 He,t)- and (p vector,p vector')-cross sections are compatible with the transition strength predictions as obtained from random phase approximation (RPA) calculations. This means that the Δ isobar quenching mechanism is likely to be rather small. (orig.)

  13. Geometric covers, graph orientations, counter games

    DEFF Research Database (Denmark)

    Berglin, Edvin

    -directed graph is dynamic (can be altered by some outside actor), some orientations may need to be reversed in order to maintain the low out-degree. We present a new algorithm that is simpler than earlier work, yet matches or outperforms the efficiency of these results with very few exceptions. Counter games...... example is Line Cover, also known as Point-Line Cover, where a set of points in a geometric space are to be covered by placing a restricted number of lines. We present new FPT algorithms for the sub-family Curve Cover (which includes Line Cover), as well as for Hyperplane Cover restricted to R 3 (i...... are a type of abstract game played over a set of counters holding values, and these values may be moved between counters according to some set of rules. Typically they are played between two players: the adversary who tries to concentrate the greatest value possible in a single counter, and the benevolent...

  14. 21 CFR 866.2180 - Manual colony counter.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2180 Manual colony counter. (a) Identification. A manual colony counter is a device intended for medical purposes that consists...

  15. P-Refinement and P-Threads (Preprint)

    National Research Council Canada - National Science Library

    Dong, Steven; Karniadakis, George E

    2002-01-01

    ...]) in d dimensions, which is higher than lower-order methods. In this paper, we demonstrate that by employing multi-threading within MPI processes we manage to counter- balance the cost increase associated with P-refinement...

  16. On generating counter-rotating streamwise vortices

    KAUST Repository

    Winoto, S H

    2015-09-23

    Counter-rotating streamwise vortices are known to enhance the heat transfer rate from a surface and also to improve the aerodynamic performance of an aerofoil. In this paper, some methods to generate such counter-rotating vortices using different methods or physical conditions will be briefly considered and discussed.

  17. On generating counter-rotating streamwise vortices

    KAUST Repository

    Winoto, S H; Mitsudharmadi, Hatsari; Budiman, A C; Hasheminejad, S M; Nadesan, T; Tandiono; Low, H T; Lee, T S

    2015-01-01

    Counter-rotating streamwise vortices are known to enhance the heat transfer rate from a surface and also to improve the aerodynamic performance of an aerofoil. In this paper, some methods to generate such counter-rotating vortices using different methods or physical conditions will be briefly considered and discussed.

  18. Bienestar público o financiarización: contratos, consultorías, asociaciones público privadas y compras públicas. (Colonización del gobierno

    Directory of Open Access Journals (Sweden)

    Diana Vicher

    2017-09-01

    Full Text Available En el escenario mundial configurado como resultado de la retracción del Estado y escasez de recursos, grupos económicos nacionales e internacionales, sobre todo empresas trasnacionales y capital financiero, han encontrado (tal vez ayudados a generar o incidido para hacerlo posible, nuevas oportunidades de negocio (ganancias que se han abierto gracias a la desregulación de varios sectores del gobierno que incluyen servicios públicos y la creciente inclusión de compras gubernamentales en los tratados de libre comercio. Por ello de manera creciente, desde la década de 1980, esos sectores empresariales (consultorías trasnacionales, calificadoras de riesgo, certificadoras como ISO y financieros (deuda pública y asociaciones público privadas se han posicionado en importantes espacios de toma de decisiones, al tiempo que han tenido acceso a explotar actividades que estaban a cargo de gobiernos y administraciones públicas. Estas "nuevas formas de financiamiento" y opciones de prestación de servicios públicos, presentan diferentes contradicciones que se deben analizar para valorar los efectivos beneficios que pueden aportar, o bien para revelar sus consecuencias reales. Este trabajo revisa la directriz general de la contratación y concesión gubernamental que incluye carteras de servicios de las consultorías trasnacionales al gobierno nacional, la expansión del mercado de compras gubernamentales y formas de financiamiento de asociaciones público privadas.

  19. Particle identification aerogel counter with n=1.13 for {pi}/K separation

    Energy Technology Data Exchange (ETDEWEB)

    Barnyakov, A.Yu.; Barnyakov, M.Yu. [Budker Institute of Nuclear Physics, 11, akademika Lavrentieva prospect, Novosobirsk 630090 (Russian Federation); Beloborodov, K.I., E-mail: K.I.Beloborodov@inp.nsk.s [Budker Institute of Nuclear Physics, 11, akademika Lavrentieva prospect, Novosobirsk 630090 (Russian Federation); Novosibirsk State University, 2, Pirogova Street, Novosibirsk 630090 (Russian Federation); Bobrovnikov, V.S.; Buzykaev, A.R. [Budker Institute of Nuclear Physics, 11, akademika Lavrentieva prospect, Novosobirsk 630090 (Russian Federation); Danilyuk, A.F. [Boreskov Institute of Catalysis, 5, akademika Lavrentieva prospect, Novosibirsk 630090 (Russian Federation); Golubev, V.B. [Budker Institute of Nuclear Physics, 11, akademika Lavrentieva prospect, Novosobirsk 630090 (Russian Federation); Novosibirsk State University, 2, Pirogova Street, Novosibirsk 630090 (Russian Federation); Kirillov, V.L. [Boreskov Institute of Catalysis, 5, akademika Lavrentieva prospect, Novosibirsk 630090 (Russian Federation); Kononov, S.A. [Budker Institute of Nuclear Physics, 11, akademika Lavrentieva prospect, Novosobirsk 630090 (Russian Federation); Kravchenko, E.A. [Budker Institute of Nuclear Physics, 11, akademika Lavrentieva prospect, Novosobirsk 630090 (Russian Federation); Novosibirsk State University, 2, Pirogova Street, Novosibirsk 630090 (Russian Federation); Onuchin, A.P. [Budker Institute of Nuclear Physics, 11, akademika Lavrentieva prospect, Novosobirsk 630090 (Russian Federation); Martin, K.A. [Budker Institute of Nuclear Physics, 11, akademika Lavrentieva prospect, Novosobirsk 630090 (Russian Federation); Novosibirsk State Technical University, 20, Karl Marx prospect, Novosibirsk 630092 (Russian Federation); Serednyakov, S.I. [Budker Institute of Nuclear Physics, 11, akademika Lavrentieva prospect, Novosobirsk 630090 (Russian Federation); Novosibirsk State University, 2, Pirogova Street, Novosibirsk 630090 (Russian Federation)

    2010-11-01

    The paper is devoted to the cosmic muon tests of particle identification system for the SND detector at the new VEPP-2000 e{sup +}e{sup -} collider. The goal of the tests is to measure average signal for the relativistic particles. The measurements of the average signal were done at five different points of the counter. Obtained values of the signal are close to 10 photoelectrons. Preliminary results for misidentification probability for {pi} and K mesons with the energy of 1000 MeV are presented.

  20. Counter Traction Makes Endoscopic Submucosal Dissection Easier

    OpenAIRE

    Oyama, Tsuneo

    2012-01-01

    Poor counter traction and poor field of vision make endoscopic submucosal dissection (ESD) difficult. Good counter traction allows dissections to be performed more quickly and safely. Position change, which utilizes gravity, is the simplest method to create a clear field of vision. It is useful especially for esophageal and colon ESD. The second easiest method is clip with line method. Counter traction made by clip with line accomplishes the creation of a clear field of vision and suitable co...

  1. Israel's Counter-Terrorism Strategy and its Effectiveness

    National Research Council Canada - National Science Library

    Smith, Jerry D

    2005-01-01

    This thesis analyzes Israeli counter-terrorism strategy and its effectiveness. Because of ongoing suicide attacks from Palestinian and other terrorist organizations, Israel will continue to have an aggressive counter-terrorism strategy...

  2. 21 CFR 201.21 - Declaration of presence of phenylalanine as a component of aspartame in over-the-counter and...

    Science.gov (United States)

    2010-04-01

    ... component of aspartame in over-the-counter and prescription drugs for human use. 201.21 Section 201.21 Food... component of aspartame in over-the-counter and prescription drugs for human use. (a) Aspartame is the... acids are so combined to form aspartame (1-methyl N-L-α-aspartyl-L-phenylalanine), they produce an...

  3. Single n+-i-n+ InP nanowires for highly sensitive terahertz detection.

    Science.gov (United States)

    Peng, Kun; Parkinson, Patrick; Gao, Qian; Boland, Jessica L; Li, Ziyuan; Wang, Fan; Mokkapati, Sudha; Fu, Lan; Johnston, Michael B; Tan, Hark Hoe; Jagadish, Chennupati

    2017-03-24

    Developing single-nanowire terahertz (THz) electronics and employing them as sub-wavelength components for highly-integrated THz time-domain spectroscopy (THz-TDS) applications is a promising approach to achieve future low-cost, highly integrable and high-resolution THz tools, which are desirable in many areas spanning from security, industry, environmental monitoring and medical diagnostics to fundamental science. In this work, we present the design and growth of n + -i-n + InP nanowires. The axial doping profile of the n + -i-n + InP nanowires has been calibrated and characterized using combined optical and electrical approaches to achieve nanowire devices with low contact resistances, on which the highly-sensitive InP single-nanowire photoconductive THz detectors have been demonstrated. While the n + -i-n + InP nanowire detector has a only pA-level response current, it has a 2.5 times improved signal-to-noise ratio compared with the undoped InP nanowire detector and is comparable to traditional bulk THz detectors. This performance indicates a promising path to nanowire-based THz electronics for future commercial applications.

  4. Position sensitive proportional counters as focal plane detectors

    International Nuclear Information System (INIS)

    Ford, J.L.C. Jr.

    1979-01-01

    The rise time and charge division techniques for position decoding with RC-line proportional counters are reviewed. The advantages that these detectors offer as focal plane counters for nuclear spectroscopy performed with magnetic spectrographs are discussed. The theory of operation of proportional counters as position sensing devices is summarized, as well as practical aspects affecting their application. Factors limiting the position and energy resolutions obtainable with a focal plane proportional counter are evaluated and measured position and energy loss values are presented for comparison. Detector systems capable of the multiparameter measurements required for particle identification, background suppression and ray-tracing are described in order to illustrate the wide applicability of proportional counters within complex focal plane systems. Examples of the use of these counters other than with magnetic spectrographs are given in order to demonstrate their usefulness in not only nuclear physics but also in fields such as solid state physics, biology, and medicine. The influence of the new focal plane detector systems on future magnetic spectrograph designs is discussed. (Auth.)

  5. CORNELL: CLEO's counters

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    Particle identification by measuring ionization is complicated by the fact that the energy lost to ionization in passing through matter has large fluctuations, first calculated by Landau. These large fluctuations imply that many measurements must be made in order to determine the most probable ionization value that is characteristic of the particle type. The JADE chamber at PETRA and the TPC chamber at PEP measure both the ionization and the momenta of tracks in the same device. In the CLEO experiment at Cornell's CESR ring, ionization is measured in dedicated energy loss counters contained in each of the eight octants surrounding the drift chamber and superconducting coil. The last of these were installed in the summer of 1981, replacing Cherenkov counters that were used while the energy loss counters were being developed and built

  6. Channel coincidence counter: version 1

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1980-06-01

    A thermal neutron coincidence counter has been designed for the assay of fast critical assembly fuel drawers and plutonium-bearing fuel rods. The principal feature of the detector is a 7-cm by 7-cm by 97-cm detector channel, which provides a uniform neutron detection efficiency of 16% along the central 40 cm of the channel. The electronics system is identical to that used for the High-Level Neutron Coincidence Counter

  7. Charge and velocity resolution of Cerenkov counters in a beam of accelerated heavy nuclei

    International Nuclear Information System (INIS)

    Cantin, M.; Goret, P.; Jorrand, J.; Jouan, R.; Juliusson, E.; Koch, L.; Maubras, Y.; Mestreau, P.; Petrou, N.; Rio, Y.; Soutoul, A.; Cawood, P.; Linney, A.

    1975-01-01

    The response of various Cerenkov radiators to oxygen and nitrogen nuclei with energies ranging between 2.1GeV/n and 300MeV/n is presented. The velocity and charge resolutions are analyzed in relation to the possible use of these counters for chemical and isotopic analysis of the primary cosmic ray nuclei [fr

  8. Gamma-ray scintillation counter hodoscope for the experiment S140

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    The experiment S140 was set-up in the East Hall (beam p14) by the CERN-Munich-Cracow Collaboration to study the production by negative kaons of a neutral meson associated to a Lambda. Here, the liquid hydrogen target (inside the horizontal black tube) is withdrawn from the surrounding cylindrical gamma-ray-measuring scintillation counter hodoscope.

  9. Fabrication of p-type porous GaN on silicon and epitaxial GaN

    OpenAIRE

    Bilousov, Oleksandr V.; Geaney, Hugh; Carvajal, Joan J.; Zubialevich, Vitaly Z.; Parbrook, Peter J.; Giguere, A.; Drouin, D.; Diaz, Francesc; Aguilo, Magdalena; O'Dwyer, Colm

    2013-01-01

    Porous GaN layers are grown on silicon from gold or platinum catalyst seed layers, and self-catalyzed on epitaxial GaN films on sapphire. Using a Mg-based precursor, we demonstrate p-type doping of the porous GaN. Electrical measurements for p-type GaN on Si show Ohmic and Schottky behavior from gold and platinum seeded GaN, respectively. Ohmicity is attributed to the formation of a Ga2Au intermetallic. Porous p-type GaN was also achieved on epitaxial n-GaN on sapphire, and transport measurem...

  10. Over-the-counter medications containing diphenhydramine and doxylamine used by older adults to improve sleep.

    Science.gov (United States)

    Abraham, Olufunmilola; Schleiden, Loren; Albert, Steven M

    2017-08-01

    medications than participants not taking these products (38 vs 49%, p = 0.016). Conclusion A majority of older adults in a limited sample from the United States taking an over-the-counter medication to improve sleep are taking a product containing diphenhydramine or doxylamine, both of which are classified as potentially inappropriate for older adults. Awareness of the safety risks of over-the-counter medications and addressing conditions that impact sleep quality could be facilitated through consultation with pharmacists and other healthcare providers.

  11. The E.P.R. (European Water Pressurized Reactor): a choice from the past that should close future?

    International Nuclear Information System (INIS)

    Marignac, Y.

    2003-11-01

    The present note discusses, by opening questions, different counter-arguments, of the French energy policy such the attempt to adapt the E.P.R., a technological project conceived in an old policy frame, to actual economical and environmental realities. (N.C.)

  12. Efficiency calibration of solid track spark auto counter

    International Nuclear Information System (INIS)

    Wang Mei; Wen Zhongwei; Lin Jufang; Liu Rong; Jiang Li; Lu Xinxin; Zhu Tonghua

    2008-01-01

    The factors influencing detection efficiency of solid track spark auto counter were analyzed, and the best etch condition and parameters of charge were also reconfirmed. With small plate fission ionization chamber, the efficiency of solid track spark auto counter at various experiment assemblies was re-calibrated. The efficiency of solid track spark auto counter at various experimental conditions was obtained. (authors)

  13. Generalization of the development of liquid-sparkling counter

    International Nuclear Information System (INIS)

    Bian Zhengzhu; Zhang Jue; Zhang Jinwei

    2006-01-01

    This paper includes five parts. It not only reviews the development history of liquid-sparkling counter but refers that the appearance of coincident circuit is its milestone. The paper summarizes the resembled hard ware and soft ware and soft ware of liquid-sparkling counter of indoor and overseas, and prospects the development of liquid-sparkling counter in our country. (authors)

  14. Calibration of proportional counters in microdosimetry

    International Nuclear Information System (INIS)

    Varma, M.N.

    1982-01-01

    Many microdosimetric spectra for low LET as well as high LET radiations are measured using commercially available (similar to EG and G) Rossi proportional counters. This paper discusses the corrections to be applied to data when calibration of the counter is made using one type of radiation, and then the counter is used in a different radiation field. The principal correction factor is due to differences in W-value of the radiation used for calibration and the radiation for which microdosimetric measurements are made. Both propane and methane base tissue-equivalent (TE) gases are used in these counters. When calibrating the detectors, it is important to use the correct stopping power value for that gas. Deviations in y-bar/sub F/ and y-bar/sub D/ are calculated for 60 Co using different extrapolation procedures from 0.15 keV/μm to zero event size. These deviations can be as large as 30%. Advantages of reporting microdosimetric parameters such as y-bar/sub F/ and y-bar/sub D/ above a certain minimum cut-off are discussed

  15. Biological N2 fixation mainly controlled by Sphagnum tissue N:P ratio in ombrotrophic bogs

    Science.gov (United States)

    Zivkovic, Tatjana; Moore, Tim R.

    2017-04-01

    Most of the 18 Pg nitrogen (N) accumulated in northern nutrient-poor and Sphagnum-dominated peatlands (bogs and fens) can be attributed to N2-fixation by diazotrophs either associated with the live Sphagnum or non-symbiotically in the deeper peat such as through methane consumption close to the water table. Where atmospheric N deposition is low (Sphagnum, suggested by the increase in tissue N:P to >16. It is unclear how Sphagnum-hosted diazotrophic activity may be affected by N deposition and thus changes in N:P ratio. First, we investigated the effects of long-term addition of different sources of nitrogen (0, 1.6, 3.2 and 6.4 g N m-2 y-1as NH4Cl and NaNO3), and phosphorus (5 g P m-2 y-1as KH2PO4) on Sphagnum nutrient status (N, P and N:P ratio), net primary productivity (NPP) and Sphagnum-associated N2fixation at Mer Bleue, a temperate ombrotrophic bog. We show that N concentration in Sphagnum tissue increased with larger rates of N addition, with a stronger effect on Sphagnum from NH4 than NO3. The addition of P created a 3.5 fold increase in Sphagnum P content compared to controls. Sphagnum NPP decreased linearly with the rise in N:P ratio, while linear growth declined exponentially with increase in Sphagnum N content. Rates of N2-fixation determined in the laboratory significantly decreased in response to even the smallest addition of both N species. In contrast, the addition of P increased N2 fixation by up to 100 times compared to N treatments and up to 5-30 times compared to controls. The change in N2-fixation was best modeled by the N:P ratio, across all experimental treatments. Secondly, to test the role of N:P ratio on N2-fixation across a range of bogs, eight study sites along the latitudinal gradient from temperate, boreal to subarctic zone in eastern Canada were selected. From each bog, two predominant microptopographies, hummocks and hollows, were tested for both N2-fixation activity in the laboratory and Sphagnum tissue concentrations of N, P and N:P

  16. The Origin of the United Nations "Global Counter-Terrorism System"

    Directory of Open Access Journals (Sweden)

    William B. Messmer

    2010-11-01

    Full Text Available Este artículo explica los orígenes de sistema global antiterrorista de las Naciones Unidas. Nosotros argüimos que tres factores determinan las características de un sistema descentralizado y de estados centralizados. El primero es la reacción de la ONU contra los ataques terroristas del 11 de septiembre de 2001. El segundo factor es la cada vez mayor relevancia de las redes de gobierno transnacional. La tercera fuerza son los intereses y los asuntos del Consejo de Seguridad permanente, que últimamente determina la arquitectura del sistema.9/11, United Nations, Security Council, transnacional governance networks,counter-terrorism system.___________________________ABSTRACT:This article explains the origins of the United Nations’ global counter-terrorism system. We argue that three factors shaped the system’s decentralized and state-centered characteristics. The first is the UN’s reactions to terrorism prior to the attacks of 11 September 2001. The second factor is the growing relevance of transnational governance networks. The third force is the interests and concerns of the Security Council’s permanent representative interests, which ultimately shaped the system’s architecture.Keywords: 9/11; United Nations; Security Council; transnacional governance networks; counter-terrorism system

  17. Efectos a la salud y exposición a p,p'-DDT y p,p'-DDE: el caso de México

    OpenAIRE

    Torres-Sánchez,Luisa; López-Carrillo,Lizbeth

    2007-01-01

    Basado en la revisión sistemática de 32 artículos publicados en PubMed-Medline hasta enero del 2006 y utilizando como palabras clave DDT exposure, human, milk y Mexico; este estudio analiza la situación acerca de la exposición en México a difenildicloroetano (DDT) y su principal metabolito p,p,'-DDE, así como, su posible repercusión sobre la salud humana. Aún cuando, el uso del DDT se suspendió en 1999, los estudios evaluados reportan niveles importantes de p,p'-DDE, en muestras biológicas de...

  18. Advertising health: the case for counter-ads.

    Science.gov (United States)

    Dorfman, L; Wallack, L

    1993-01-01

    Public service advertisements have been used by many in hopes of "selling" good health behaviors. But selling good behavior--even if it could be done more effectively--is not the best goal for using mass media to prevent health problems. Personal behavior is only part of what determines health status. Social conditions and the physical environment are important determinants of health that are usually ignored by health promotion advertising. Public service advertising may be doing more harm than good if it is diverting attention from more effective socially based health promotion strategies. Counter-ads are one communications strategy that could be used to promote a broader responsibility for rectifying health problems. In the tradition of advocacy advertising directly promoting policy rather than products, counter-ads promote views consistent with a public health perspective. Counter-ads set the agenda for health issues, conferring status on policy-oriented strategies for addressing health problems. The primary purpose of counter-ads is to challenge the dominant view that public health problems reflect personal health habits. They are controversial because they place health issues in a social and political context. Advertising strategies for health promotion range over a spectrum from individually oriented public service advertising to socially oriented counter-advertising. The recent anti-tobacco campaign from the California Department of Health Services represents advertisements across the spectrum. Counter-ads that focus on a politically controversial definition for health problems are an appropriate and necessary alternative to public service advertising. PMID:8265756

  19. Successive ionic layer adsorption and reaction deposited kesterite Cu{sub 2}ZnSnS{sub 4} nanoflakes counter electrodes for efficient dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Mali, Sawanta S.; Shim, Chang Su; Hong, Chang Kook, E-mail: hongck@chonnam.ac.kr

    2014-11-15

    Highlights: • Cu{sub 2}ZnSnS{sub 4} nanoflakes by SILAR technique. • Hydrothermal synthesis of TiO{sub 2}. • Counter electrode for DSSC application. • 4.48% conversion efficiency. - Abstract: In this investigation, we have successfully synthesized Cu{sub 2}ZnSnS{sub 4} (CZTS) nanoflakes by successive ionic layer adsorption and reaction (SILAR) method and used as a counter electrode in the hydrothermally grown TiO{sub 2} based dye sensitized solar cells (DSSCs). The prepared CZTS nanoflakes were characterized using X-ray powder diffraction (XRD), field emission scanning electron microscopy (FESEM), micro Raman spectroscopy and energy dispersive analysis. Our DSSCs results revealed that, compared with conventional Pt/FTO counter electrode DSSCs, nanoflakes of p-type CZTS as the photocathode and n-type TiO{sub 2} thin films as the photoanode shows an increased short circuit current (13.35 mA/cm{sup 2}) with 4.84% power conversion efficiency. The detailed interface properties of were analyzed by electrochemical impedance spectroscopy (EIS) measurements.

  20. Manufacturing P-N junctions in germanium bodies

    International Nuclear Information System (INIS)

    Hall, R.N.

    1980-01-01

    A method of producing p-n junctions in Ge so as to facilitate their use as radiation detectors involves forming a body of high purity p-type germanium, diffusing lithium deep into the body, in the absence of electrolytic processes, to form a junction between n-type and p-type germanium greater than 1 mm depth. (UK)

  1. Over-the-counter drugs block heart accumulation of MIBG

    International Nuclear Information System (INIS)

    Sherman, P.S.; Fisher, S.J.; Wieland, D.M.; Sisson, J.C.

    1985-01-01

    Previous work in the authors' laboratory using chemically sympathectomized animals showed that > 50% of meta-iodobenzyl-guanidine (MIBG) in the heart is localized in adrenergic nerves. In the present study, commonly used drugs known to alter the uptake and/or release of norepinephrine by adrenergic neurons have been evaluated for their effect on the biodistribution of MIBG. Pseudoephedrine (Sudafed), phenylpropanolamine (Dexatrim) and phenylephrine (Neosynephrine) were administered (5 mg/kg, i.p.) to rats; amphetamine was also evaluated (0.8mg/kg, i.p.). Thirty minutes later I-125-MIBG (0.2-0.4 Ci/mm) was injected i.v.; animals (N=3) were sacrificed 2 h following radiotracer. Compared to controls (N = 3), drug pretreatments resulted in large decreases in radiotracer concentration in adrenergic-rich tissues such as left atrium, left ventricle, spleen and parotid glands. Pseudoephedrine caused decreases (%) of 78, 57, 48 and 35 in the four tissues, respectively. Each of the four drugs caused a greater decrease in I-125-MIBG concentration in the left atrium than in the left ventricle. Comparative studies using H-3-norepinephrine are in progress. Entex, a nasal decongestant containing both phenylephrine and phenylpropanolamine, markedly diminished the heart and salivary gland accumulation of I-123-MIBG in a normal male volunteer. These preliminary studies suggest that commonly used sympathomimetic agents, including some over-the-counter preparations, decrease the accumulation of MIBG in adrenergic neurons. These results also suggest that patients should be carefully screened for drug usage prior to MIBG scintigraphy of the heart

  2. Evaluation of the cross-sections for the reactions 19F(n,2n)18F, 31P(n,p)31Si, 93Nb(n,n')sup(93m)Nb and 103Rh(n,n')sup(103m)Rh

    International Nuclear Information System (INIS)

    Strohmaier, B.; Tagesen, S.; Vonach, H.

    1980-01-01

    The cross-sections for the four important neutron dosimetry reactions 19 F(n,2n) 18 F, 31 P(n,p) 31 Si, 93 Nb(n,n')sup(93m)Nb and 103 Rh(n,n')sup(103m)Rh were evaluated in the neutron energy range from threshold to 20 MeV. For the 19 F(n,2n) reaction the evaluation could be based entirely on experimental data; for the reactions 31 P(n,p) 31 Si and 103 Rh(n,n')sup(103m)Rh large gaps in the experimental excitation functions and large discrepancies between the existing data made it necessary to supplement the experimental data by cross-section calculations and to give about equal weight to the experimental and calculated cross-sections. For the 93 Nb(n,n')sup(93m)Nb reaction the evaluation had to be based entirely on the theoretically calculated cross-sections. All data sets were critically reviewed and obviously erroneous data sets were disregarded. If necessary, the data were renormalized in order to take into account adjustments in corresponding standard cross-sections and decay schemes. For each evaluated cross-sections also an uncertainty (on a 1sigma confidence level) was derived taking into account the errors given by the experimentalists, the general consistency of the experimental data and the estimated errors of the theoretically calculated cross-sections. (orig.) [de

  3. Cerenkov counter for the experiment NA3

    CERN Multimedia

    1978-01-01

    The program of the NA3 experiment included the study of hadronic interactions with a large transverse momentum pT, thus the inclusion in the set-up of three gas threshold Cerenkov counters of large acceptance. The photo shows the downstream part of the second Cerenkov (located at the output of the magnet). The yellow membrane is a temporary protection for the optics (shown in photo 7810540X) to be taken away when fixing this part to the gas tank (entering the magnet and not shown). The photomultipliers all around are heavily shielded.

  4. Comunicación pública: repensar la comunicación para la democracia

    OpenAIRE

    Botero Montoya, Luis Horacio; Galvis Ortiz, Carlos Alberto

    2011-01-01

    Hablar de comunicación pública denota redundancia, dado que el concepto comunicación es un bien público, de interés general, abierto e integrador de la sociedad. Diversos elementos han fracturado el papel que la comunicación tiene como bien público...

  5. Construction of monoenergetic neutron calibration fields using 45Sc(p, n)45Ti reaction at JAEA.

    Science.gov (United States)

    Tanimura, Y; Saegusa, J; Shikaze, Y; Tsutsumi, M; Shimizu, S; Yoshizawa, M

    2007-01-01

    The 8 and 27 keV monoenergetic neutron calibration fields have been developed by using (45)Sc(p, n)(45)Ti reaction. Protons from a 4-MV Pelletron accelerator are used to bombard a thin scandium target evaporated onto a platinum disc. The proton energies are finely adjusted to the resonance to generate the 8 and 27 keV neutrons by applying a high voltage to the target assemblies. The neutron energies were measured using the time-of-flight method with a lithium glass scintillation detector. The neutron fluences at a calibration point located at 50 cm from the target were evaluated using Bonner spheres. A long counter was placed at 2.2 m from the target and at 60 degrees to the direction of the proton beam in order to monitor the fluence at the calibration point. Fluence and dose equivalent rates at the calibration point are sufficient to calibrate many types of the neutron survey metres.

  6. Counter - Drug: Mandate for the Army.

    Science.gov (United States)

    1991-03-01

    this comprehensive review will provide a basis for responding to new missions assigned...observations for determining the short-, mid-, and long-term direction of Army support to the national counter-drug effort. Also, this comprehensive review will provide...and long-term direction of Army support to the national counter-drug effort. Also, this comprehensive review will provide a basis for responding

  7. Hardware support for software controlled fast multiplexing of performance counters

    Science.gov (United States)

    Salapura, Valentina; Wisniewski, Robert W.

    2013-01-01

    Performance counters may be operable to collect one or more counts of one or more selected activities, and registers may be operable to store a set of performance counter configurations. A state machine may be operable to automatically select a register from the registers for reconfiguring the one or more performance counters in response to receiving a first signal. The state machine may be further operable to reconfigure the one or more performance counters based on a configuration specified in the selected register. The state machine yet further may be operable to copy data in selected one or more of the performance counters to a memory location, or to copy data from the memory location to the counters, in response to receiving a second signal. The state machine may be operable to store or restore the counter values and state machine configuration in response to a context switch event.

  8. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A new concept is presented explaining changes in spectrometric parameters of proportional counters which occur due to varying count rate. The basic feature of this concept is that the gas gain of the counter remains constant in a wide range of count rate and that the decrease in the pulse amplitude and the detorioration of the energy resolution observed are the results of changes in the shape of original current pulses generated in the active volume of the counter. In order to confirm the validity of this statement, measurements of the gas amplification factor have been made in a wide count rate range. It is shown that above a certain critical value the gas gain depends on both the operating voltage and the count rate. (author)

  9. High Sensitive pH Sensor Based on AlInN/GaN Heterostructure Transistor

    Directory of Open Access Journals (Sweden)

    Yan Dong

    2018-04-01

    Full Text Available The AlInN/GaN high-electron-mobility-transistor (HEMT indicates better performances compared with the traditional AlGaN/GaN HEMTs. The present work investigated the pH sensor functionality of an analogous HEMT AlInN/GaN device with an open gate. It was shown that the Al0.83In0.17N/GaN device demonstrates excellent pH sense functionality in aqueous solutions, exhibiting higher sensitivity (−30.83 μA/pH for AlInN/GaN and −4.6 μA/pH for AlGaN/GaN and a faster response time, lower degradation and good stability with respect to the AlGaN/GaN device, which is attributed to higher two-dimensional electron gas (2DEG density and a thinner barrier layer in Al0.83In0.17N/GaN owning to lattice matching. On the other hand, the open gate geometry was found to affect the pH sensitivity obviously. Properly increasing the width and shortening the length of the open gate area could enhance the sensitivity. However, when the open gate width is too larger or too small, the pH sensitivity would be suppressed conversely. Designing an optimal ratio of the width to the length is important for achieving high sensitivity. This work suggests that the AlInN/GaN-based 2DEG carrier modulated devices would be good candidates for high-performance pH sensors and other related applications.

  10. High Sensitive pH Sensor Based on AlInN/GaN Heterostructure Transistor.

    Science.gov (United States)

    Dong, Yan; Son, Dong-Hyeok; Dai, Quan; Lee, Jun-Hyeok; Won, Chul-Ho; Kim, Jeong-Gil; Chen, Dunjun; Lee, Jung-Hee; Lu, Hai; Zhang, Rong; Zheng, Youdou

    2018-04-24

    The AlInN/GaN high-electron-mobility-transistor (HEMT) indicates better performances compared with the traditional AlGaN/GaN HEMTs. The present work investigated the pH sensor functionality of an analogous HEMT AlInN/GaN device with an open gate. It was shown that the Al 0.83 In 0.17 N/GaN device demonstrates excellent pH sense functionality in aqueous solutions, exhibiting higher sensitivity (−30.83 μA/pH for AlInN/GaN and −4.6 μA/pH for AlGaN/GaN) and a faster response time, lower degradation and good stability with respect to the AlGaN/GaN device, which is attributed to higher two-dimensional electron gas (2DEG) density and a thinner barrier layer in Al 0.83 In 0.17 N/GaN owning to lattice matching. On the other hand, the open gate geometry was found to affect the pH sensitivity obviously. Properly increasing the width and shortening the length of the open gate area could enhance the sensitivity. However, when the open gate width is too larger or too small, the pH sensitivity would be suppressed conversely. Designing an optimal ratio of the width to the length is important for achieving high sensitivity. This work suggests that the AlInN/GaN-based 2DEG carrier modulated devices would be good candidates for high-performance pH sensors and other related applications.

  11. Surfactant and counter-ion distribution in styrene-butyl acrylate-acrylic acid dry latex submonolayers

    Directory of Open Access Journals (Sweden)

    Keslarek Amauri José

    2004-01-01

    Full Text Available Styrene-butyl acrylate-acrylic acid latex submonolayers prepared using a non-reactive phosphate surfactant together with a reactive sulfonate surfactant were examined in a transmission microscope using electron energy loss spectroscopy imaging (ESI-TEM. Phosphorus is nearly absent from the particles core but it is detected in a thick shell and in unusual, strongly scattering structures with a low carbon content, and largely made out of inorganic phosphate. P is also dispersed outside the particles, while S is uniformly distributed within then. The Na and N elemental maps show that the respective monovalent ions (Na+ and NH4+ have different distributions, in the latex: Na signal within the particles is stronger than in the background, while N is accumulated at the particle borders. The distributions of surfactant and counter-ions are thus different from some current assumptions, but they support recent results on the distribution of ionic constituents in latex films, by scanning electric potential microscopy.

  12. Determination of radon concentration in ground water in Aichi Prefecture by liquid scintillation counter

    International Nuclear Information System (INIS)

    Onuma, Akiko; Shimizu, Michihiko; Chaya, Kunio; Hamamura, Norikatsu; Kagami, Tadaaki.

    1982-01-01

    The radon (Rn) concentration in ground water in Aichi Prefecture was determined by the liquid scintillation counter (LSC) method. The measurement of radon by LSC was made by integration counting, keeping the constant LS quantity in a vial and the constant geometry of a photomultiplier. The recovery rate of radon with 226-radium standard solution was 98.7%. The coefficient of variation in the measured values of radon concentration in ground water in Aichi Prefecture by the LSC method was 4.9%. For the same ground waters in the prefecture, the radon concentrations measured by the LSC method and by the conventional IM fontactoscope method were examined comparatively. This gave a regression formula of LSC value = 0.583 x IM value + 1.325 (n = 70, coefficient of correlation 0.966), indicating significant correlation between the two. It is thus shown that the LSC method is an effective means as the IM fontactoscope method. (J.P.N.)

  13. Design of a hybrid gas proportional counter with CdTe guard counters for sup 1 sup 4 C dating system

    CERN Document Server

    Zhang, L; Hinamoto, N; Nakazawa, M; Yoshida, K

    2002-01-01

    Nowadays uniform, low-cost and large-size compound semiconductor detectors are available up to several square centimeters. We are trying to combine this technology with conventional gas detectors to upgrade an anticoincidence type proportional counter, Oeschger-type thin wall counter of 2.2 l, used for a sup 1 sup 4 C dating facility at the University of Tokyo. In order to increase the ratio of the signal to the background for smaller quantity of samples less than 1 g, an effective approach is to minimize the detector volume at higher gas pressure. However, the anticoincidence function suffers from such a small volume. Therefore we designed a new active wall gas counter of 0.13 l counting volume using CdTe compound semiconductor detectors as the wall of the gas proportional counter to perform anticoincidence. Simulation study showed that at noise thresholds less than 70 keV, the wall counters can reject above 99.8% of events arising from outer gamma rays. Measured noise levels of CdTe detectors were smaller t...

  14. Synthesis and reactivity of TADDOL-based chiral Fe(II) PNP pincer complexes-solution equilibria between κ(2)P,N- and κ(3)P,N,P-bound PNP pincer ligands.

    Science.gov (United States)

    Holzhacker, Christian; Stöger, Berthold; Carvalho, Maria Deus; Ferreira, Liliana P; Pittenauer, Ernst; Allmaier, Günter; Veiros, Luis F; Realista, Sara; Gil, Adrià; Calhorda, Maria José; Müller, Danny; Kirchner, Karl

    2015-08-07

    Treatment of anhydrous FeX2 (X = Cl, Br) with 1 equiv. of the asymmetric chiral PNP pincer ligands PNP-R,TAD (R = iPr, tBu) with an R,R-TADDOL (TAD) moiety afforded complexes of the general formula [Fe(PNP)X2]. In the solid state these complexes adopt a tetrahedral geometry with the PNP ligand coordinated in κ(2)P,N-fashion, as shown by X-ray crystallography and Mössbauer spectroscopy. Magnetization studies led to a magnetic moment very close to 4.9μB reflecting the expected four unpaired d-electrons (quintet ground state). In solution there are equilibria between [Fe(κ(3)P,N,P-PNP-R,TAD)X2] and [Fe(κ(2)P,N-PNP-R,TAD)X2] complexes, i.e., the PNP-R,TAD ligand is hemilabile. At -50 °C these equilibria are slow and signals of the non-coordinated P-TAD arm of the κ(2)P,N-PNP-R,TAD ligand can be detected by (31)P{(1)H} NMR spectroscopy. Addition of BH3 to a solution of [Fe(PNP-iPr,TAD)Cl2] leads to selective boronation of the pendant P-TAD arm shifting the equilibrium towards the four-coordinate complex [Fe(κ(2)P,N-PNP-iPr,TAD(BH3))Cl2]. DFT calculations corroborate the existence of equilibria between four- and five-coordinated complexes. Addition of CO to [Fe(PNP-iPr,TAD)X2] in solution yields the diamagnetic octahedral complexes trans-[Fe(κ(3)P,N,P-PNP-iPr,TAD)(CO)X2], which react further with Ag(+) salts in the presence of CO to give the cationic complexes trans-[Fe(κ(3)P,N,P-PNP-iPr,TAD)(CO)2X](+). CO addition most likely takes place at the five coordinate complex [Fe(κ(3)P,N,P-PNP-iPr,TAD)X2]. The mechanism for the CO addition was also investigated by DFT and the most favorable path obtained corresponds to the rearrangement of the pincer ligand first from a κ(2)P,N- to a κ(3)P,N,P-coordination mode followed by CO coordination to [Fe(κ(3)P,N,P-PNP-iPr,TAD)X2]. Complexes bearing tBu substituents do not react with CO. Moreover, in the solid state none of the tetrahedral complexes are able to bind CO.

  15. Tests of BF3 counters with getter

    International Nuclear Information System (INIS)

    Comte, R.; Dauphin, G.

    1968-01-01

    BF 3 counters with addition of a getter have been developed to improve operation characteristics of these detectors in presence of strong gamma flows. The getter is made of an active coal deposit on the cathode. As noticed by other studies, the degradation of these counters is related to the exposure to strong neutron flows and to gamma radiations. The authors report tests performed on these counters with a brief presentation of the counters, and a presentation of the test installation. A threshold curve and an amplitude spectrum are obtained, and counting is performed for a fixed threshold before and after the exposure of detectors to variable doses of γ radiation. The results after a first 2 hour long irradiation, a 230 hour long second irradiation, and a third irradiation under high voltage (2100 V) are discussed. Thermal tests are then performed and commented

  16. Determination of carrier diffusion length in p- and n-type GaN

    Science.gov (United States)

    Hafiz, Shopan; Metzner, Sebastian; Zhang, Fan; Monavarian, Morteza; Avrutin, Vitaliy; Morkoç, Hadis; Karbaum, Christopher; Bertram, Frank; Christen, Jürgen; Gil, Bernard; Özgür, Ümit

    2014-03-01

    Diffusion lengths of photo-excited carriers along the c-direction were determined from photoluminescence (PL) measurements in p- and n-type GaN epitaxial layers grown on c-plane sapphire by metal-organic chemical vapor deposition. The investigated samples incorporate a 6 nm thick In0.15Ga0.85N active layer capped with either 500 nm p- GaN or 1300 nm n-GaN. The top GaN layers were etched in steps and PL from the InGaN active region and the underlying layers was monitored as a function of the top GaN thickness upon photogeneration near the surface region by above bandgap excitation. Taking into consideration the absorption in the active and underlying layers, the diffusion lengths at 295 K and at 15 K were measured to be about 92 ± 7 nm and 68 ± 7 nm for Mg-doped p-type GaN and 432 ± 30 nm and 316 ± 30 nm for unintentionally doped n-type GaN, respectively. Cross-sectional cathodoluminescence line-scan measurement was performed on a separate sample and the diffusion length in n-type GaN was measured to be 280 nm.

  17. Qualidade negociada: avaliação e contra-regulação na escola pública Negotiated quality: assessment and counter-regulation in public schools

    Directory of Open Access Journals (Sweden)

    Luiz Carlos de Freitas

    2005-10-01

    Full Text Available A "qualidade negociada" é proposta como alternativa de contra-regulação e apoio a processos de mudança complexos nas escolas. Por este conceito, a qualidade é produto de um processo de avaliação institucional construído coletivamente, tendo como referência o projeto político-pedagógico da escola. Defende-se a inadequação de estratégias de "difusão" de mudanças a partir de um centro irradiador destas, sem ter como referência os problemas reais da escola. Analisa-se o conceito de "serviço público" procurando entender suas características particulares. Dado que o servidor público tem estabilidade e atua no interior de relações específicas com o poder, com o dinheiro e com o tempo, procura-se mostrar que, a exemplo das políticas públicas neoliberais (PSDB-PFL, as políticas públicas participativas (pt e aliados também terão problemas se não reconhecerem tais especificidades e se não instalarem processos de avaliação negociados que criem compromissos pactuados e incentivem novas formas de organização nas relações internas das escolas.Negotiated quality is proposed as a counter-regulation alternative favoring complex change processes at school. This concept sees quality as produced through an institutional assessment process, collectively built, whose reference is the political-pedagogical project of school. The text substantiates the unsuitability of strategies that "spread" changes from a center, without any reference to the actual problems of school. It analyzes the concept of public services so as to understand its peculiar characteristics. Since civil servants have job security and work within specific relationships to power, money and time, it attempts to show that, as was the case with the neoliberal public policies (PSDB-PFL, the participative public policies (pt and allies will also be faced with problems if they do not acknowledge such specificities and implement negotiated assessment processes that

  18. Axial p-n junction and space charge limited current in single GaN nanowire

    Science.gov (United States)

    Fang, Zhihua; Donatini, Fabrice; Daudin, Bruno; Pernot, Julien

    2018-01-01

    The electrical characterizations of individual basic GaN nanostructures, such as axial nanowire (NW) p-n junctions, are becoming indispensable and crucial for the fully controlled realization of GaN NW based devices. In this study, electron beam induced current (EBIC) measurements were performed on two single axial GaN p-n junction NWs grown by plasma-assisted molecular beam epitaxy. I-V characteristics revealed that both ohmic and space charge limited current (SCLC) regimes occur in GaN p-n junction NW. Thanks to an improved contact process, both the electric field induced by the p-n junction and the SCLC in the p-part of GaN NW were disclosed and delineated by EBIC signals under different biases. Analyzing the EBIC profiles in the vicinity of the p-n junction under 0 V and reverse bias, we deduced a depletion width in the range of 116-125 nm. Following our previous work, the acceptor N a doping level was estimated to be 2-3 × 1017 at cm-3 assuming a donor level N d of 2-3 × 1018 at cm-3. The hole diffusion length in n-GaN was determined to be 75 nm for NW #1 and 43 nm for NW #2, demonstrating a low surface recombination velocity at the m-plane facet of n-GaN NW. Under forward bias, EBIC imaging visualized the electric field induced by the SCLC close to p-side contact, in agreement with unusual SCLC previously reported in GaN NWs.

  19. Axial p-n junction and space charge limited current in single GaN nanowire.

    Science.gov (United States)

    Fang, Zhihua; Donatini, Fabrice; Daudin, Bruno; Pernot, Julien

    2018-01-05

    The electrical characterizations of individual basic GaN nanostructures, such as axial nanowire (NW) p-n junctions, are becoming indispensable and crucial for the fully controlled realization of GaN NW based devices. In this study, electron beam induced current (EBIC) measurements were performed on two single axial GaN p-n junction NWs grown by plasma-assisted molecular beam epitaxy. I-V characteristics revealed that both ohmic and space charge limited current (SCLC) regimes occur in GaN p-n junction NW. Thanks to an improved contact process, both the electric field induced by the p-n junction and the SCLC in the p-part of GaN NW were disclosed and delineated by EBIC signals under different biases. Analyzing the EBIC profiles in the vicinity of the p-n junction under 0 V and reverse bias, we deduced a depletion width in the range of 116-125 nm. Following our previous work, the acceptor N a doping level was estimated to be 2-3 × 10 17 at cm -3 assuming a donor level N d of 2-3 × 10 18 at cm -3 . The hole diffusion length in n-GaN was determined to be 75 nm for NW #1 and 43 nm for NW #2, demonstrating a low surface recombination velocity at the m-plane facet of n-GaN NW. Under forward bias, EBIC imaging visualized the electric field induced by the SCLC close to p-side contact, in agreement with unusual SCLC previously reported in GaN NWs.

  20. COUNTER-ROTATION IN RELATIVISTIC MAGNETOHYDRODYNAMIC JETS

    Energy Technology Data Exchange (ETDEWEB)

    Cayatte, V.; Sauty, C. [Laboratoire Univers et Théories, Observatoire de Paris, UMR 8102 du CNRS, Université Paris Diderot, F-92190 Meudon (France); Vlahakis, N.; Tsinganos, K. [Department of Astrophysics, Astronomy and Mechanics, Faculty of Physics, University of Athens, 15784 Zografos, Athens (Greece); Matsakos, T. [Department of Astronomy and Astrophysics, The University of Chicago, Chicago, IL 60637 (United States); Lima, J. J. G., E-mail: veronique.cayatte@obspm.fr [Centro de Astrofísica, Universidade do Porto, Rua das Estrelas, 4150-762 Porto (Portugal)

    2014-06-10

    Young stellar object observations suggest that some jets rotate in the opposite direction with respect to their disk. In a recent study, Sauty et al. showed that this does not contradict the magnetocentrifugal mechanism that is believed to launch such outflows. Motion signatures that are transverse to the jet axis, in two opposite directions, have recently been measured in M87. One possible interpretation of this motion is that of counter-rotating knots. Here, we extend our previous analytical derivation of counter-rotation to relativistic jets, demonstrating that counter-rotation can indeed take place under rather general conditions. We show that both the magnetic field and a non-negligible enthalpy are necessary at the origin of counter-rotating outflows, and that the effect is associated with a transfer of energy flux from the matter to the electromagnetic field. This can be realized in three cases: if a decreasing enthalpy causes an increase of the Poynting flux, if the flow decelerates, or if strong gradients of the magnetic field are present. An illustration of the involved mechanism is given by an example of a relativistic magnetohydrodynamic jet simulation.

  1. Efectividad en la gestión pública chilena

    Directory of Open Access Journals (Sweden)

    Mauricio Olavarría Gambi

    2010-01-01

    Full Text Available Al preguntarse ¿qué hace a un servicio público ser efectivo?, este trabajo identifica, primero, los organismos estatales considerados efectivos por diversos indicadores y tipos de públicos, y luego halla que las variables que explicarían la efectividad de esos servicios públicos son liderazgo y visión, reorientación de la misión, orientación al usuario, utilización intensiva de TIC y gestión estratégica. El trabajo también señala que así como los servicios pueden mejorar, también pueden decaer, y que por ello el ejercicio de identificación de las agencias estatales efectivas e inefectivas debe ser periódico. Ello contribuye a establecer procesos de mejora continua en la gestión pública, la herramienta más importante con la que dispone el Estado para implementar políticas públicas orientadas a resolver problemas públicos y, por lo tanto, a acrecentar el bienestar de los ciudadanos.

  2. Numerical modelling of tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Segur, P.; Colautti, P.

    1995-01-01

    In this paper a survey is given of the various numerical techniques employed to study the transport of ionising particles inside a TEPC. The first part is devoted to the description of the general concept of particle transport calculations. Thereafter, the different methods available to study transport phenomena and energy deposition in the sensitive volume and in counter walls are described. Finally, the basic ionisation mechanisms which may occur in a counter are described, and the non-equilibrium phenomena which play an important role mainly for counters that are to be used in measurements at the nanodosemeter level are studied. (author)

  3. 78 FR 29672 - Cardiovascular Devices; Reclassification of External Counter-Pulsating Devices for Treatment of...

    Science.gov (United States)

    2013-05-21

    .... FDA-2013-N-0487] Cardiovascular Devices; Reclassification of External Counter- Pulsating Devices for... proposed rule (44 FR 13426, March 9, 1979), the Cardiovascular Device Classification Panel (the 1979 Panel... of Subjects in 21 CFR Part 870 Medical devices, Cardiovascular devices...

  4. Cross sections for the reactions 54Fe(n,α)51Cr, 54Fe(n,p)54Mn, and 56Fe(n,p)56Mn

    International Nuclear Information System (INIS)

    Paulsen, A.; Widera, R.; Arnotte, F.; Liskien, H.

    1979-01-01

    Ratios of cross sections for the reactions 54 Fe(n,α) 51 Cr, 54 Fe(n,p) 54 Mn, and 56 Fe(n,p) 56 Mn were measured by the activation technique. In the 6- to 10-MeV energy range, quasi-monoenergetic neutrons produced by the D(d,n) source reaction were used, while additional data were obtained between 12 and 17 MeV by use of the T(d,n) source reaction. The cross-section ratios have accuracies between 1.5 and 4.5%. 1 figure, 3 tables

  5. Neutron dosimetry using proportional counters with tissue equivalent walls

    International Nuclear Information System (INIS)

    Kerviller, H. de

    1965-01-01

    The author reminds the calculation method of the neutron absorbed dose in a material and deduce of it the conditions what this material have to fill to be equivalent to biological tissues. Various proportional counters are mode with walls in new tissue equivalent material and filled with various gases. The multiplication factor and neutron energy response of these counters are investigated and compared with those obtained with ethylene lined polyethylene counters. The conditions of working of such proportional counters for neutron dosimetry in energy range 10 -2 to 15 MeV are specified. (author) [fr

  6. Graphene in ohmic contact for both n-GaN and p-GaN

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Haijian; Liu, Zhenghui; Shi, Lin; Xu, Gengzhao; Fan, Yingmin; Huang, Zengli [Suzhou Institute of Nano-Tech and Nano-Bionics, CAS, Suzhou 215123 (China); Wang, Jianfeng; Ren, Guoqiang; Xu, Ke, E-mail: kxu2006@sinano.ac.cn [Suzhou Institute of Nano-Tech and Nano-Bionics, CAS, Suzhou 215123 (China); Suzhou Nanowin Science and Technology Co., Ltd., Suzhou 215123 (China)

    2014-05-26

    The wrinkles of single layer graphene contacted with either n-GaN or p-GaN were found both forming ohmic contacts investigated by conductive atomic force microscopy. The local I–V results show that some of the graphene wrinkles act as high-conductive channels and exhibiting ohmic behaviors compared with the flat regions with Schottky characteristics. We have studied the effects of the graphene wrinkles using density-functional-theory calculations. It is found that the standing and folded wrinkles with zigzag or armchair directions have a tendency to decrease or increase the local work function, respectively, pushing the local Fermi level towards n- or p-type GaN and thus improving the transport properties. These results can benefit recent topical researches and applications for graphene as electrode material integrated in various semiconductor devices.

  7. Theoretical speciation of ethylenediamine-N-(o-hydroxyphenylacetic)-N'-(p-hydroxyphenylacetic) acid (o,p-EDDHA) in agronomic conditions.

    Science.gov (United States)

    Yunta, Felipe; García-Marco, Sonia; Lucena, Juan J

    2003-08-27

    The presence of ethylenediamine-N-(o-hydroxyphenylacetic)-N'-(p-hydroxyphenylacetic) acid (o,p-EDDHA) as the second largest component in commercial EDDHA iron chelates has recently been demonstrated. Here is reported the speciation of o,p-EDDHA by the application of a novel methodology through the determination of the complexing capacity, protonation, and Ca(2+), Mg(2+), Cu(2+), and Fe(3+) stability constants. The pM values and species distribution in solution, hydroponic, and soil conditions were obtained. Due to the para position of one phenol group in o,p-EDDHA, the protonation constants and Ca and Mg stability constants have different values from those of o,o-EDDHA and p,p-EDDHA regioisomers. o,p-EDDHA/Fe(3+) stability constants are higher than those of EDTA/Fe(3+) but lower than those of o,o-EDDHA/Fe(3+). The sequence obtained for pFe is o,o-EDDHA/Fe(3+) >/= o,p-EDDHA/Fe(3+) > EDTA/Fe(3+). o,p-EDDHA/Fe(3+) can be used as an iron chelate in hydroponic conditions. Also, it can be used in soils with limited Cu availability.

  8. Charged particle identification: Cherenkov counters at ISABELLE

    International Nuclear Information System (INIS)

    Etkin, A.; Kostoulas, I.; Leith, D.W.G.S.; Thun, R.

    1977-01-01

    A brief summary is given of a study of Cherenkov counters for ISABELLE. The study was certainy not exhaustive and was meant primarily to suggest future detector development. A substantial research effort is needed in order to insure that Cherenkov counters utilizing photoionization are fully exploited

  9. Preparation of p-type GaN-doped SnO2 thin films by e-beam evaporation and their applications in p-n junction

    Science.gov (United States)

    Lv, Shuliang; Zhou, Yawei; Xu, Wenwu; Mao, Wenfeng; Wang, Lingtao; Liu, Yong; He, Chunqing

    2018-01-01

    Various transparent GaN-doped SnO2 thin films were deposited on glass substrates by e-beam evaporation using GaN:SnO2 targets of different GaN weight ratios. It is interesting to find that carrier polarity of the thin films was converted from n-type to p-type with increasing GaN ratio higher than 15 wt.%. The n-p transition in GaN-doped SnO2 thin films was explained for the formation of GaSn and NO with increasing GaN doping level in the films, which was identified by Hall measurement and XPS analysis. A transparent thin film p-n junction was successfully fabricated by depositing p-type GaN:SnO2 thin film on SnO2 thin film, and a low leakage current (6.2 × 10-5 A at -4 V) and a low turn-on voltage of 1.69 V were obtained for the p-n junction.

  10. Formation of p-n-p junction with ionic liquid gate in graphene

    International Nuclear Information System (INIS)

    He, Xin; Tang, Ning; Duan, Junxi; Zhang, Yuewei; Lu, Fangchao; Xu, Fujun; Yang, Xuelin; Gao, Li; Wang, Xinqiang; Shen, Bo; Ge, Weikun

    2014-01-01

    Ionic liquid gating is a technique which is much more efficient than solid gating to tune carrier density. To observe the electronic properties of such a highly doped graphene device, a top gate made of ionic liquid has been used. By sweeping both the top and back gate voltage, a p-n-p junction has been created. The mechanism of forming the p-n-p junction has been discussed. Tuning the carrier density by ionic liquid gate can be an efficient method to be used in flexible electronics

  11. The Banking Counter-Guarantee. Juridical Regime

    Directory of Open Access Journals (Sweden)

    Postolache Rada

    2009-06-01

    Full Text Available Not so much studied by the specialised literature, the banking counter-guarantee may beconfounded with the other types of guarantee which frequently go with the guaranteed obligation –simple guarantee, collateral guarantee, the confirmation of the guarantee. The counter-guarantee may bean independent or accessory obligation, as the case may be, exclusively governed by its text, accordingto the parties’ will. At the same time, it is a complex juridical act, a contract whose contents cannot beset apart from the contracts connected form an “economic” point of view. The counter-guarantee is theresult of the banking practice and is generated by the need to make amends for the flaws generated bythe direct guarantee. The present research is focused on the analysis of the banking practice, normativeacts, jurisprudence and banking juridical literature.

  12. The scintillation counter system at the SAPHIR detector

    International Nuclear Information System (INIS)

    Bour, D.

    1989-10-01

    The scintillation-counters system of the SAPHIR-detector at the stretcher accelerator ELSA in Bonn consists of 64 counters. It supplies a fast hadronic trigger and is utilizised for the particle identification by time of flight measurements. Prototypes of the counters (340x21.25 x 6.0 cm 3 ) had been tested. The contribution to the resolution of the time of flight measurement was measured to σ=125 ps, the effective light velocity to 17.5 ns/cm and the attenuation length of 7.8 m. A pion kaon separation is possible up to a momentum of 1 GeV/c with time of flight measurement. With the first photon-beam at SAPHIR the counters were tested, first triggers were obtained and evaluated. (orig.) [de

  13. Development of a low-cost whole body counter

    International Nuclear Information System (INIS)

    Smith, M.H.; Gross, G.P.

    1991-01-01

    This paper documents the construction and calibration of a whole-body counter for the Radiation Safety Office of the Mayo Clinic in Rochester, MN. Changes in the federal regulations may require improved documentation of internal dose for radiation workers. A relatively inexpensive and simple chair-type whole-body counter may suit the needs of many organizations for in vivo assessment of gamma emitting radionuclides. A simple calibration phantom and a spreadsheet computer program were developed in conjunction with the counter. The spreadsheet can be used to calculate an estimate of committed effective dose equivalent based on activity in a subject and data from ICRP Publication 30. Using a count time of 10 minutes, the counter's minimum detectable activity ranged from 370 Bq to 1,110 Bq for 60 Co and 57 Co respectively. Other institutions will be able to assemble whole-body counters at low cost, often from surplus components. The spreadsheet is easily adapted to the needs of any institution and uses current methodology to estimate internal dose

  14. Development and validation of an app-based cell counter for use in the clinical laboratory setting

    Directory of Open Access Journals (Sweden)

    Alexander C Thurman

    2015-01-01

    Full Text Available Introduction: For decades cellular differentials have been generated exclusively on analog tabletop cell counters. With the advent of tablet computers, digital cell counters - in the form of mobile applications ("apps" - now represent an alternative to analog devices. However, app-based counters have not been widely adopted by clinical laboratories, perhaps owing to a presumed decrease in count accuracy related to the lack of tactile feedback inherent in a touchscreen interface. We herein provide the first systematic evidence that digital cell counters function similarly to standard tabletop units. Methods: We developed an app-based cell counter optimized for use in the clinical laboratory setting. Paired counts of 188 peripheral blood smears and 62 bone marrow aspirate smears were performed using our app-based counter and a standard analog device. Differences between paired data sets were analyzed using the correlation coefficient, Student′s t-test for paired samples and Bland-Altman plots. Results: All counts showed excellent agreement across all users and touch screen devices. With the exception of peripheral blood basophils (r = 0.684, differentials generated for the measured cell categories within the paired data sets were highly correlated (all r ≥ 0.899. Results of paired t-tests did not reach statistical significance for any cell type (all P > 0.05, and Bland-Altman plots showed a narrow spread of the difference about the mean without evidence of significant outliers. Conclusions: Our analysis suggests that no systematic differences exist between cellular differentials obtained via app-based or tabletop counters and that agreement between these two methods is excellent.

  15. Quality control and the multicrystal counter

    International Nuclear Information System (INIS)

    Hart, G.C.; Davis, K.M.

    1983-01-01

    The reliability of multicrystal counters for use in counting large numbers of radioimmunoassay samples is studied. In particular, the dependencies of the outputs from the array of detectors, and hence their degree of matching, on the count rate and volume of the samples being counted are investigated. Quality control procedures are described to assist in the assurance of consistent performance of the counter in the clinical situation. (U.K.)

  16. Pulse formation of gas-filled counter

    International Nuclear Information System (INIS)

    Iwatani, Kazuo; Teshima, Kazunori; Shizuma, Kiyoshi; Hasai, Hiromi

    1991-01-01

    The pulse formation of gas-filled counter has been calculated by simple models for the proportional and self-quenching streamer (SQS) modes. Calculated pulse shapes of counter output have accurately reproduced the observed ones for both modes. As a result, it is shown that the special density distribution of ion pairs in a streamer can be estimated with the rising part of observed pulse shape, using the model. (author)

  17. HOW THE WAR WAS ‘ONE’: COUNTERING VIOLENT EXTREMISM AND THE SOCIAL DIMENSIONS OF COUNTER-TERRORISM IN CANADA.

    Directory of Open Access Journals (Sweden)

    Tami Amanda Jacoby

    2016-03-01

    Full Text Available The current global “war on terror” highlights a fundamental quandary for all liberal democracies seeking to counter the violent extremism of their own citizens while maintaining civic rights and freedoms. This challenge accompanies a transformation in international conflict from inter-state war and superpower rivalry, to homegrown terrorism, radicalization-to-violence, Internet propaganda, and targeting and recruitment of vulnerable persons. These new threats shift the battlefield, as traditionally defined, to the home front, as extremist violence is nurtured by and perpetrated within public spaces, such as schools, places of religious worship, civil society and the home. Today, violence emanates from within liberal democratic society and its extremist motivations bypass the very institutions that would otherwise support civic rights, freedoms and multiculturalism. As such, attempts to counter extremist violence must appeal to the political, social, cultural, religious and familial aspects of human behavior alongside a parallel shift in efforts to keep citizens safe within their own social spaces. In recent years, Canada has been introduced to home grown and lone individual terrorism with the cases of attack against armed forces personnel in Saint-Jean-sur-Richelieu and Ottawa in 2014. This article identifies the social dimensions of counter-terrorism in the Canadian context, a propitious case by which to evaluate different approaches to countering violent extremism. Canadian initiatives - simultaneously proliferating and in their infancy – raise a host of questions about counter-terrorism in liberal democratic countries. For example, why do individuals radicalize-to-violence in rights-based and multicultural societies? How and when can the liberal democratic state best temper the radicalization process in ways that are effective and procedurally just? What state-society balance works best to counter radicalized viewpoints? Who are the

  18. An efficient and target-oriented sample enrichment method for preparative separation of minor alkaloids by pH-zone-refining counter-current chromatography.

    Science.gov (United States)

    Feng, Rui-Hong; Hou, Jin-Jun; Zhang, Yi-Bei; Pan, Hui-Qin; Yang, Wenzhi; Qi, Peng; Yao, Shuai; Cai, Lu-Ying; Yang, Min; Jiang, Bao-Hong; Liu, Xuan; Wu, Wan-Ying; Guo, De-An

    2015-08-28

    An efficient and target-oriented sample enrichment method was established to increase the content of the minor alkaloids in crude extract by using the corresponding two-phase solvent system applied in pH-zone-refining counter-current chromatography. The enrichment and separation of seven minor indole alkaloids from Uncaria rhynchophylla (Miq.) Miq. ex Havil(UR) were selected as an example to show the advantage of this method. An optimized two-phase solvent system composed of n-hexane-ethyl acetate-methanol-water (3:7:1:9, v/v) was used in this study, where triethylamine (TEA) as the retainer and hydrochloric acid (HCl) as the eluter were added at the equimolar of 10mM. Crude alkaloids of UR dissolved in the corresponding upper phase (containing 10mM TEA) were extracted twice with lower phase (containing 10mM TEA) and lower phase (containing 10mM HCl), respectively, the second lower phase extract was subjected to pH-zone-refining CCC separation after alkalization and desalination. Finally, from 10g of crude alkaloids, 4g of refined alkaloids was obtained and the total content of seven target indole alkaloids was increased from 4.64% to 15.78%. Seven indole alkaloids, including 54mg isocorynoxeine, 21mg corynoxeine, 46mg isorhynchophylline, 35mg rhynchophylline, 65mg hirsutine, 51mg hirsuteine and 27mg geissoschizine methylether were all simultaneously separated from 2.5g of refined alkaloids, with the purity of 86.4%, 97.5%, 90.3%, 92.1%, 98.5%, 92.3%, and 92.8%, respectively. The total content and purities of the seven minor indole alkaloids were tested by HPLC and their chemical structures were elucidated by ESI-HRMS and (1)H NMR. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Novel fast-neutron activation counter for high repetition rate measurements

    International Nuclear Information System (INIS)

    Mahmood, S.; Springham, S. V.; Zhang, T.; Rawat, R. S.; Tan, T. L.; Krishnan, M.; Beg, F. N.; Lee, S.; Schmidt, H.; Lee, P.

    2006-01-01

    A fast-neutron beryllium activation counter has been constructed for neutron measurements on a high repetition rate deuterium plasma focus. Beryllium activation is especially suitable for measurements of DD neutron yields. The cross section for the relevant reaction, 9 Be(n,α) 6 He, results in a maximum sensitivity at the characteristic energy of the DD neutrons (∼2.5 MeV) and practically no sensitivity to neutrons with energies 6 He enabled the shot-to-shot neutron yield from the plasma focus to be measured for repetition rates from 0.2 to 3 Hz (and for a range of deuterium gas pressures). With careful analysis, the shot-to-shot yield can be measured up to a maximum repetition rate of 3 Hz, beyond which the pileup of counts from the previous shots reduces the accuracy of the measurements to an unacceptable level. This new beryllium activation counter has been cross-checked against an indium activation counter to obtain absolute neutron yields. At a charging voltage of 12.5 kV (bank energy of 2.2 kJ), the average neutron yield was found to be (7.9±0.7)x10 7 per shot (standard deviation of 4x10 7 ). It was found that activation of the plasma focus construction materials (especially aluminum) must be taken into account

  20. Influence of tube volume on measurement uncertainty of GM counters

    Directory of Open Access Journals (Sweden)

    Stanković Koviljka Đ.

    2010-01-01

    Full Text Available GM counters are often used in radiation detection since they generate a strong signal which can be easily detected. The working principal of a GM counter is based on the interaction of ionizing radiation with the atoms and molecules of the gas present in the counter's tube. Free electrons created as a result of this interaction become initial electrons, i. e. start an avalanche process which is detected as a pulse of current. This current pulse is independent of the energy imparted on the gas, that being the main difference between a GM counter and the majority of other radiation detectors. In literature, the dependence on the incidence of radiation energy, tube's orientation and characteristics of the reading system are quoted as the main sources of measurement uncertainty of GM counters. The aim of this paper is to determine the dependence of measurement uncertainty of a GM counter on the volume of its counter's tube. The dependence of the pulse current on the size of the counter's tube has, therefore, been considered here, both in radial and parallel geometry. The initiation and expansion of the current pulse have been examined by means of elementary processes of electrical discharge such as the Markov processes, while the changes in the counter's tube volume were put to test by the space - time enlargement law. The random variable known as the 'current pulse in the counter's tube' (i. e. electrical breakdown of the electrode configuration has also been taken into account and an appropriate theoretical distribution statistically determined. Thus obtained theoretical results were then compared to corresponding experimental results established in controlled laboratory conditions.

  1. Reduction of degraded events in miniaturized proportional counters

    Energy Technology Data Exchange (ETDEWEB)

    Plaga, R.; Kirsten, T. (Max Planck Inst. fuer Kernphysik, Heidelberg (Germany))

    1991-11-15

    A method to reduce the number of degraded events in miniaturized proportional counters is described. A shaping of the outer cathode leads to a more uniform gas gain along the counter axis. The method is useful in situations in which the total number of decay events is very low. The effects leading to degraded events are studied theoretically and experimentally. The usefulness of the method is demonstrated by using it for the proportional counter of the GALLEX solar neutrino experiment. (orig.).

  2. Reaction πN → ππN near threshold

    International Nuclear Information System (INIS)

    Frlez, E.

    1993-11-01

    The LAMPF E1179 experiment used the π 0 spectrometer and an array of charged particle range counters to detect and record π + π 0 , π 0 p, and π + π 0 p coincidences following the reaction π + p → π 0 π + p near threshold. The total cross sections for single pion production were measured at the incident pion kinetic energies 190, 200, 220, 240, and 260 MeV. Absolute normalizations were fixed by measuring π + p elastic scattering at 260 MeV. A detailed analysis of the π 0 detection efficiency was performed using cosmic ray calibrations and pion single charge exchange measurements with a 30 MeV π - beam. All published data on πN → ππN, including our results, are simultaneously fitted to yield a common chiral symmetry breaking parameter ξ =-0.25±0.10. The threshold matrix element |α 0 (π 0 π + p)| determined by linear extrapolation yields the value of the s-wave isospin-2 ππ scattering length α 0 2 (ππ) = -0.041±0.003 m π -1 , within the framework of soft-pion theory

  3. Política pública de biblioteca pública en Medellín : hacia la construcción de una guía de evaluación

    OpenAIRE

    Bornacelly, Jaime; Quintero Castro, Nathalia; Cuartas Celis, Deiman; Restrepo, María Camila; Gil Aristizábal, Duban

    2014-01-01

    Desde un enfoque cualitativo e interpretativo, se indaga sobre la política pública en biblioteca pública en Medellín y su evaluación; para ello se adelanta una investigación documental, para saber sobre la definición y los objetivos de la biblioteca pública en la normatividad existente; los aportes de los académicos y lo dicho por algunos representantes del sector bibliotecario local; se identifica qué es una política pública, sus pasos y el análisis para configurar una propuesta de referente...

  4. The n,{gamma} discrimination in recoil-proton proportional counters. Application to the measurement of fast neutron spectra; Discrimination n,{gamma} dans les compteurs proportionnels a protons de recul. Application a la mesure des spectres de neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Jeandidier, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    A description is given of a spectrometry chain working in the energy range of a few keV to 1 MeV, and designed for measurement of fast neutron spectra. It consists of detectors, recoil proton proportional counters built especially for this work by R. COMTE (DEG/SER) and which make it possible to cover the energy range and also associated electronic equipment. A brief description is first given of the physical processes involved: (n,p) collisions in the gas, influence of {gamma} radiation; the method of discrimination is then presented. It is based on the difference in the rise-times of the pulses. In the experiments described here the use of a bi-parametric system made it possible to employ the most simple discrimination device, based on the fact that the high frequency gamma pulse components are, at a given energy, weaker than those of the neutron pulses. Results are given of measurements carried out on the Van der Graaff (mono-energetic neutrons for testing the linearity of the chain and the resolving power of the counters), and of those made in a sub-critical system Hug at Cadarache. (author) [French] On decrit une chaine de spectrometrie travaillant dans le domaine d'energie de quelques keV a 1 MeV destinee a la mesure des spectres de neutrons rapides. Elle comprend les detecteurs, compteurs proportionnels a protons de recul, realises specialement pour cette etude par M. R. COMTE (DEG/SER), permettant de couvrir la gamme d'energie et l'electronique associee. Apres un rappel des processus physiques mis en jeu: chocs (n,p) dans les gaz, influence des rayonnements {gamma}, on expose la methode de discrimination utilisee. Celle-ci est basee sur la difference des temps de montee des impulsions. Au cours des experiences rapportees ici, la mise en oeuvre d'un ensemble bi-parametrique a permis d'utiliser le dispositif de discrimination le plus simple, base sur la remarque que les composantes a haute frequence des impulsions {gamma} sont, a energie egale, plus faibles

  5. The n,{gamma} discrimination in recoil-proton proportional counters. Application to the measurement of fast neutron spectra; Discrimination n,{gamma} dans les compteurs proportionnels a protons de recul. Application a la mesure des spectres de neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Jeandidier, C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    A description is given of a spectrometry chain working in the energy range of a few keV to 1 MeV, and designed for measurement of fast neutron spectra. It consists of detectors, recoil proton proportional counters built especially for this work by R. COMTE (DEG/SER) and which make it possible to cover the energy range and also associated electronic equipment. A brief description is first given of the physical processes involved: (n,p) collisions in the gas, influence of {gamma} radiation; the method of discrimination is then presented. It is based on the difference in the rise-times of the pulses. In the experiments described here the use of a bi-parametric system made it possible to employ the most simple discrimination device, based on the fact that the high frequency gamma pulse components are, at a given energy, weaker than those of the neutron pulses. Results are given of measurements carried out on the Van der Graaff (mono-energetic neutrons for testing the linearity of the chain and the resolving power of the counters), and of those made in a sub-critical system Hug at Cadarache. (author) [French] On decrit une chaine de spectrometrie travaillant dans le domaine d'energie de quelques keV a 1 MeV destinee a la mesure des spectres de neutrons rapides. Elle comprend les detecteurs, compteurs proportionnels a protons de recul, realises specialement pour cette etude par M. R. COMTE (DEG/SER), permettant de couvrir la gamme d'energie et l'electronique associee. Apres un rappel des processus physiques mis en jeu: chocs (n,p) dans les gaz, influence des rayonnements {gamma}, on expose la methode de discrimination utilisee. Celle-ci est basee sur la difference des temps de montee des impulsions. Au cours des experiences rapportees ici, la mise en oeuvre d'un ensemble bi-parametrique a permis d'utiliser le dispositif de discrimination le plus simple, base sur la remarque que les composantes a haute frequence des impulsions {gamma} sont, a

  6. Proton-recoil proportional-counter array for neutron-image construction

    International Nuclear Information System (INIS)

    Fink, C.L.; Eichholz, J.J.; DeVolpi, A.

    1984-01-01

    The fuel-motion measurement capability of the fast-neutron hodoscope has been upgraded by the addition of a 360-detector proton-recoil proportional-counter array, which detects high-energy fission neutrons. The current sensitive amplifier/discriminator module for each detector fits into a 12.7 by 12.7 by 102 mm package and cost less than $100 per module. It has a 50 ns rise time, a noise level of 100 nA, and a deadtime per event of 200 ns. Provision has been provided for the independent adjustment of the input current versus discriminator voltage for each module. The new proportional-counters cost approximately $400 each. Each detector has been tested to have the same gain versus voltage response. A space-charge model relating count-rate changes to space-charge effects has also been developed. The new detector array has been operational for approximately two years and has become the main detector system in fuel-motion analysis. It has significantly improved the linearity, stability, count-rate capability, and setup ease of the hodoscope

  7. P-spray implant optimization for the fabrication of n-in-p microstrip detectors

    International Nuclear Information System (INIS)

    Fleta, Celeste; Lozano, Manuel; Pellegrini, Giulio; Campabadal, Francesca; Rafi, Joan Marc; Ullan, Miguel

    2007-01-01

    This work reports on an optimization study of the p-spray profile for the fabrication of n-in-p microstrip silicon detectors. A thorough simulation process of the expected electrical performance of different p-spray technologies was carried out. The best technological options for the p-spray implantation were chosen for the fabrication of miniature n-in-p microstrip detectors on high resistivity FZ wafers at the IMB-CNM clean room. The main conclusions derived from the simulations, and the electrical performance of a sample of the fabricated devices is presented

  8. Case study for co and counter swirling domestic burners

    Directory of Open Access Journals (Sweden)

    Ashraf Kotb

    2018-03-01

    Full Text Available In this case study, the influence of equivalence ratio for co and counter-swirl domestic burners compared with non-swirl design on the thermal efficiency as well as CO emissions has been studied using liquefied petroleum gas (LPG. Also, the flame stability, and pot height, which is defined as the burner-to-pot distance (H, of the co and counter domestic burners were compared. The analysis of the results showed that, for both swirl burners co and counter one the thermal efficiency under all operation conditions tested is higher than the non-swirled burner (base burner. For example, the thermal efficiency increased by 8.8%, and 5.8% than base burner for co and counter swirl, respectively at Reynolds number equal 2000 and equivalence ratio 1. The co and counter swirl burners show lower CO emission than the base burner. The co swirl burner has wider operation range than counter swirl. With the increase of pot height, the thermal efficiency of all burners decreases because the flame and combustion gases are cooled due to mixing with ambient air. As a result, the heat transfer is decreased due to atmospheric loss, which decrease the thermal efficiency.

  9. Investigations of thin p-GaN light-emitting diodes

    DEFF Research Database (Denmark)

    Fadil, Ahmed; Ou, Yiyu; Iida, Daisuke

    2016-01-01

    We investigate device performance of InGaN light-emitting diodes with a 30-nm p-GaN layer. The metallization used to separate the p-contact from plasmonic metals, reveals limitations on current spreading which reduces surface plasmonic enhancement.......We investigate device performance of InGaN light-emitting diodes with a 30-nm p-GaN layer. The metallization used to separate the p-contact from plasmonic metals, reveals limitations on current spreading which reduces surface plasmonic enhancement....

  10. Portable counter for geological research

    Energy Technology Data Exchange (ETDEWEB)

    Russell, O J

    1949-05-01

    A portable counter which has been developed for prospecting for radio-active uranium and thorium minerals, for general geological investigations, and as an ultra-sensitive detector of lost or mislaid radium, is described. The aforementioned general usage includes the identification of changes in strata by means of the investigation of the slight amount of residual activity pressent in most minerals. The apparatus, which consists essentially of a scaled-down version of a standard laboratory Geiger-Muller counter, is highly sensitive since a variation equivalent to 4% of the cosmic ray background can be detected by a three-minute count.

  11. ''Conventional'' Cerenkov counters at ISABELLE

    International Nuclear Information System (INIS)

    Foley, K.J.

    1977-01-01

    Cherenkov counters to be used with ISABELLE are described. The three counters used in the Hadron Spectrometer can be used to identify particles in the range 10 to 40 GeV/c with pions separated from heavier particles down to approximately 3 GeV/c. A longer spectrometer for 400 x 400 GeV operation should also be used. The spectrometers may be used with CO 2 and H 2 . The range of particle identification of 8 to 60 GeV/c with pions separated from heavier particles down to approximately 5 GeV/c is possible

  12. Cosmic Ray Background Analysis For A Cargo Container Counter

    International Nuclear Information System (INIS)

    Ensslin, Norbert; Geist, W.H.; Lestone, J.P.; Mayo, D.R.; Menlove, Howard O.

    2001-01-01

    We have developed a new model for calculating the expected yield of cosmic-ray spallation neutrons in a Cargo Container Counter, and we have benchmarked the model against measurements made with several existing large neutron counters. We also developed two versions of a new measurement uncertainty prediction code based on Microsoft Excel spreadsheets. The codes calculate the minimum detectability limit for the Cargo Container Counter for either neutron singles or doubles counting, and also propagate the uncertainties associated with efficiency normalization flux monitors and cosmic ray flux monitors. This paper will describe the physics basis for this analysis, and the results obtained for several different counter designs.

  13. The Need for a United Nations Global Counter-Terrorism Coordinator

    Directory of Open Access Journals (Sweden)

    Howard Stoffer

    2013-08-01

    Full Text Available The case for a high level United Nations (UN Counter-Terrorism Coordinator position within the UN system has become increasingly urgent in 2013. This need has diluted some Member State reticence to creating a new Assistant Secretary-General position that would supervise and manage the existing counter-terrorism structures in the UN system. A Coordinator would have a basic responsibility to keep track of all of the activities of many formal inter-governmental organisations operating at the international, regional and sub-regional level and would also work closely with national counter-terrorism focal points. In this Policy Brief, Dr. Howard Stoffer reviews the debate among Security Council and Fifth Committee members about the efficacy of establishing a senior UN Global Counter-Terrorism Coordinator. He argues that the creation of such a position could lead to a restructuring of the UN counter-terrorism architecture as well as its funding within the UN budget and among donors. The position would eventually make the UN overall counter-terrorism effort, under the UN Global Counter-Terrorism Strategy, a stronger, more effective and more efficient process with measurable impact on the ground among Member States.

  14. Multi-element proportional counter for radiation protection measurements

    International Nuclear Information System (INIS)

    Kliauga, P.; Rossi, H.H.; Johnson, G.

    1988-01-01

    This article discusses design modifications of a multi-element proportional counter. The original counter exhibited poor resolution, as measured by the width of the event-size spectrum for low-energy photons. It was also suspected that the field inside each volume was not sufficiently symmetric. Results of the modifications showed that a dramatic improvement in resolution could be obtained in the chamber with tissue-equivalent septa if their potentials were adjusted to obtain optimal resolution. The full width at half maximum then approached, although it did not equal, that of a standard spherical counter

  15. Lifetime characteristics of Gaiger-Muller counters

    Directory of Open Access Journals (Sweden)

    Kartalović Nenad M.

    2016-01-01

    Full Text Available This paper discusses the process of functional aging of Geiger-Muller counters. Two types of Geiger-Muller counter chambers were characterized in an experiment using a combined constant voltage. Chamber A had a coaxial geometry and chamber B had a plan-parallel geometry. The experimental results indicate that the aging process was faster in the case of chambers with a coaxial geometry. The results are explained based on the process of electrical discharges in gasses.

  16. Recoil-proton fast-neutron counter telescope

    Energy Technology Data Exchange (ETDEWEB)

    Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R. (Padua Univ. (Italy). Ist. di Fisica); Galeazzi, G.; Bressanini, G.

    1981-12-01

    A recoil-proton neutron counter telescope is described composed of a solid-state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time of flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV.

  17. Recoil-proton fast-neutron-counter telescope

    Energy Technology Data Exchange (ETDEWEB)

    Galeazzi, G.; Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R.; Bressanini, G.

    1981-01-01

    A proton-recoil neutron counter telescope is described composed of a solid state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time-of-flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV, presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV.

  18. 78 FR 79304 - Cardiovascular Devices; Reclassification of External Counter-Pulsating Devices for Treatment of...

    Science.gov (United States)

    2013-12-30

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 870 [Docket No. FDA-2013-N-0487] Cardiovascular Devices; Reclassification of External Counter- Pulsating Devices for...--CARDIOVASCULAR DEVICES 0 1. The authority citation for 21 CFR part 870 continues to read as follows: Authority...

  19. Effects of multiple substitution upon the P...N noncovalent interaction

    International Nuclear Information System (INIS)

    Scheiner, Steve

    2011-01-01

    Graphical abstract: The presence of one halogen opposite the N results in strong attraction between P and N. This force is little affected by identity of Y atoms, whether H or halogen. Highlights: → Strong attractive force directly between trivalent P and N atoms. → P...N force is unlike H-bonds or halogen bonds, but stronger than both. → Multiple halogenation beyond a single atom on P slightly weakens the interaction. - Abstract: The attractive noncovalent interaction of a P atom with N is derived primarily from two sources. Charge transfer from the N lone pair into the σ * antibonding orbital of a P-X bond that is turned away from the N atom combines with attractive Coulombic forces. As in the case of H-bonding, which is parallel in some ways to P...N attraction, placement of an electron-withdrawing substituent on the P atom enhances both of these components, and strengthens the overall interaction. However, in stark contrast with H-bonding, halogenation beyond monosubstitution does not lead to any further strengthening of the P...N noncovalent bond. Indeed, di and tri-substitution lead to small reductions in the interaction energy. In all cases, the geometry which contains a P...N bond is more stable than other candidate structures, some of which contain hydrogen or halogen bonds.

  20. Presettable up-down CAMAC counter for 24 bit

    International Nuclear Information System (INIS)

    Kuhn, K.; Meyer, U.; Weidhase, F.

    1976-01-01

    A module containing a presettable binary up-down CAMAC counter for 24 bit is described. The use of dataway is discussed. As an example for application in nuclear physics, control of beam position by the up-down counter is illustrated

  1. La gestión de recursos humanos en la administración pública

    Directory of Open Access Journals (Sweden)

    Manuel Martins Kidito Xavier da Gama

    2014-06-01

    Full Text Available La administración es un concepto que se refiere tanto a la actividad privada como a la pública, por ello se dice que la administración es universal, dado que cualquier organización requiere tomar decisiones, coordinar actividades, manejar personal, así como evaluar la ejecución dirigida hacia objetivos de grupo. Por esto es necesario establecer las diferencias entre la administración pública y la privada, consideran que la administración pública aprovecha todas las experiencias de la administración en general, así como las técnicas, métodos, principios y procedimientos de la administración privada.

  2. Criticism and Counter-Criticism of Public Management: Strategy Models

    OpenAIRE

    Luis C. Ortigueira

    2007-01-01

    Critical control is very important in scientific management. This paper presents models of critical and counter-critical public-management strategies, focusing on the types of criticism and counter-criticism manifested in parliamentary political debates. The paper includes: (i) a normative model showing how rational criticism can be carried out; (ii) a normative model for oral critical intervention; and (iii) a general motivational strategy model for criticisms and counter-criticisms. The pap...

  3. [Juzhnoselkupskij slovar N. P. Grigorovskogo] / Ago Künnap

    Index Scriptorium Estoniae

    Künnap, Ago, 1941-

    2007-01-01

    Juzhnoselkupskij slovar N. P. Grigorovskogo. Obrabotka i izdanie Jevgenija Helimskogo. Südselkupisches Wörterbuch von N. P. Grigorovski. Bearbeitet und herausgegeben von Eugen Helimski, Hamburg 2007. (Hamburger Sibirische Finnougrische Materialien. Habent Sua Fata Manuscripta. Band 4)

  4. Discrimination capability of avalanche counters detecting different ionizing particles

    International Nuclear Information System (INIS)

    Prete, G.; Viesti, G.; Padua Univ.

    1985-01-01

    The discrimination capability of avalanche counters to detect different ionizing particles has been studied using a 252 Cf source. Pulse height, pulse-height resolution and timing properties have been measured as a function of the reduced applied voltage for parallel-plate and parallel-grid avalanche counters. At the highest applied voltages, space charge effects shift the pulse-height signal of the avalanche counter away from being linearly proportional to the stopping power of the detected particles and cause the pulse-height resolution to deteriorate. To optimize the avalanche counter capability, without loss of time resolution, it appears better to operate the detector at voltages well below the breakdown threshold. Measurements with 32 S ions are also reported. (orig.)

  5. Expanded and combined uncertainty in measurements by GM counters

    International Nuclear Information System (INIS)

    Stankovic, K.; Arandjic, D.; Lazarevic, Dj.; Osmokrovic, P.

    2007-01-01

    This paper deals with possible ways of obtaining expanded and combined uncertainty in measurements for four types of GM counters with a same counter's tube, in cases when the contributors of these uncertainties are cosmic background radiation and induced overvoltage phenomena. Nowadays, as a consequence of electromagnetic radiation, the latter phenomenon is especially marked in urban environments. Based on experimental results obtained, it has been established that the uncertainties of an influenced random variable 'number of pulses from background radiation' and 'number of pulses induced by overvoltage' depend on the technological solution of the counter's reading system and contribute in different ways to the expanded and combined uncertainty in measurements of the applied types of GM counters. (author)

  6. ATLAS irradiation studies of n-in-n and p-in-n silicon microstrip detectors

    CERN Document Server

    Allport, P P; Buttar, C M; Carter, J; Drage, L M; Ferrère, D; Morgan, D; Riedler, P; Robinson, D

    1999-01-01

    Prior to the module production of the ATLAS silicon microstrip tracker for the barrel and the forward wheels, the characterisation of full-size prototype silicon detectors after radiation to fluences corresponding to 10 years of ATLAS operation is required. The behaviour of p-in-n and n-in-n detectors produced by several manufacturers before and after irradiation to a fluence of 3*10/sup 14/ protons/cm/sup 2/ at the CERN PS facility is discussed. This article summarises some recent results from the ATLAS SCT collaboration. The measurements of leakage current, full depletion voltage, signal-to-noise ratio and charge collection efficiency are presented. Despite the better efficiency performance of n-in-n detectors below depletion, the collaboration chose the p-in-n technology due to its simpler and less costly production since good charge collection efficiencies were achieved at the desired maximum bias voltage. (14 refs).

  7. National survey of human body radioactivity measured by a mobile whole-body counter and installed whole-body counters

    International Nuclear Information System (INIS)

    Boddy, K.; Fenwick, J.D.; McKenzie, A.L.

    1989-05-01

    Body radioactivity in the general public has been measured in 2339 volunteers throughout the U.K. A mobile whole-body monitor visited collaborating Medical Physics Departments and data were also contributed by Medical Physics Departments possessing installed counters. Levels of body radiocaesium ranged from below detection level to 4149 Bq. Radiocaesium levels were normalised by dividing by the content of natural body potassium-40. In all cases, the dose rate to the body from radiocaesium was less than that from potassium-40. Radiocaesium levels were 2-3 times higher in N.W. England, Scotland and N. Wales than the rest of the country, but this factor is much less than the variation in deposition of Chernobyl radiocaesium. This discrepancy may be accounted for by the nationwide distribution of foodstuffs. At all sites where volunteers were monitored, the ratio of caesium-137/caesium-134 was consistent with a radiocaesium intake attributable primarily to fallout from the Chernobyl fire. (author)

  8. Lessons from History for Counter- Terrorism Strategic Communications

    NARCIS (Netherlands)

    Ingram, H.J.; Reed, A.G.

    2016-01-01

    Drawing on the Counter-terrorism Strategic Communication (CTSC) Project’s research paper “A Brief History of Propaganda during Conflict“, this Policy Brief lays out the key policy-relevant lessons for developing effective counter-terrorism strategic communications. It presents a framework of

  9. Iodine (p,n) and (d,2n) excitation function measurements

    International Nuclear Information System (INIS)

    West, H.I. Jr.; Nuckolls, R.M.; Mustafa, M.G.; Lanier, R.G.

    1991-01-01

    We have measured the nuclear excitation functions for the reactions 127 I (p,n) 127 Xe and 127 I(d,2n) 127 Xe. These results are being used in the interpretation of data obtained from nuclear test diagnostics. 15 refs., 3 figs., 3 tabs

  10. Systematics of gamma decay through low-lying vibrational levels of even--even nuclei excited by (p,p') and (n,n') reactions

    International Nuclear Information System (INIS)

    Koopman, R.P.

    1977-01-01

    A series of experiments was performed in which gamma-ray spectra were measured, using a Ge(Li) detector, for incident 7 to 26-MeV protons on the even-even vibrational nuclei 56 Fe, 62 Ni, 64 Zn, 108 Pd, 110 Cd, 114 Cd, 116 Cd, 116 Sn, 120 Sn, and 206 Pb, and for incident 14-MeV neutrons on natural Fe, Ni, Zn, Cd, Sn, and Pb. These measurements yielded gamma-ray cross sections from which it was inferred that almost all of the gamma cascades from (p,p') and (n,n') reactions passed down through the first 2 + levels. Consequently, the strength of the 2 + → 0 + gamma transitions were found to be an indirect measure of the (p,p') or (n,n') cross sections. Several types of nuclear model calculations were performed and compared with experimental results. These calculations included coupled-channel calculations to reproduce the direct, collective excitation of the low-lying levels, and statistical plus pre-equilibrium model calculations to reproduce the (p,p') and the (n,n') cross sections for comparison with the 2 + → 0 + gamma measurements. The agreement between calculation and experiment was generally good except at high energies, where pre-equilibrium processes dominate (i.e. around 26-MeV). Here discrepancies between calculations from the two different pre-equilibrium models and between the data and the calculations were found. Significant isospin mixing of T/sub greater than/ into T/sub less than/ states was necessary in order to have the calculations match the data for the (p,p') reactions, up to about 18-MeV

  11. The Effect of Electron versus Hole Photocurrent on Optoelectric Properties of p+-p-n-n+ Wz-GaN Reach-Through Avalanche Photodiodes

    Directory of Open Access Journals (Sweden)

    Moumita Ghosh

    2013-01-01

    Full Text Available The authors have made an attempt to investigate the effect of electron versus hole photocurrent on the optoelectric properties of p+-p-n-n+ structured Wurtzite-GaN (Wz-GaN reach-through avalanche photodiodes (RAPDs. The photo responsivity and optical gain of the devices are obtained within the wavelength range of 300 to 450 nm using a novel modeling and simulation technique developed by the authors. Two optical illumination configurations of the device such as Top Mounted (TM and Flip Chip (FC are considered for the present study to investigate the optoelectric performance of the device separately due to electron dominated and hole dominated photocurrents, respectively, in the visible-blind ultraviolet (UV spectrum. The results show that the peak unity gain responsivity and corresponding optical gain of the device are 555.78 mA W−1 and 9.4144×103, respectively, due to hole dominated photocurrent (i.e., in FC structure; while those are 480.56 mA W−1 and 7.8800×103, respectively, due to electron dominated photocurrent (i.e., in TM structure at the wavelength of 365 nm and for applied reverse bias of 85 V. Thus, better optoelectric performance of Wz-GaN RAPDs can be achieved when the photocurrent is made hole dominated by allowing the UV light to be shined on the n+-layer instead of p+-layer of the device.

  12. Proton-recoil proportional counter tests at TREAT

    International Nuclear Information System (INIS)

    Fink, C.L.; Eichholz, J.J.; Burrows, D.R.; DeVolpi, A.

    1979-01-01

    A methane filled proton-recoil proportional counter will be used as a fission neutron detector in the fast-neutron hodoscope. To provide meaningful fuel-motion information the proportional counter should have: a linear response over a wide range of reactor powers background ratio (the number of high energy neutrons detected must be maximized relative to low energy neutrons, and gamma ray sensitivity must be kept small); and a detector efficiency for fission neutrons above 1 MeV of approximately 1%. In addition, it is desirable that the detector and the associated amplifier/discriminator be capable of operating at counting rates in excess of 500 kHz. This paper reports on tests that were conducted on several proportional counters at the TREAT reactor

  13. Construction and calibration studies of the SAPHIR scintillation counters

    International Nuclear Information System (INIS)

    Kostrewa, D.

    1988-03-01

    For the scintillation counter system of the SAPHIR detector at the stretcher ring ELSA in Bonn 50 time of flight counters and 12 trigger counters have been built. Each of them has two photomultipliers, one at each side. A laser calibration system with a pulsed nitrogen laser as central light source to monitor these photomultipliers has been optimized. It was used to adjust the photomultipliers and to test their long and short time instabilities. (orig.)

  14. Analysis of the auger recombination rate in P+N-n-N-N HgCdTe detectors for HOT applications

    Science.gov (United States)

    Schuster, J.; Tennant, W. E.; Bellotti, E.; Wijewarnasuriya, P. S.

    2016-05-01

    Infrared (IR) photon detectors must be cryogenically cooled to provide the highest possible performance, usually to temperatures at or below ~ 150K. Such low operating temperatures (Top) impose very stringent requirements on cryogenic coolers. As such, there is a constant push in the industry to engineer new detector architectures that operate at higher temperatures, so called higher operating temperature (HOT) detectors. The ultimate goal for HOT detectors is room temperature operation. While this is not currently possibly for photon detectors, significant increases in Top are nonetheless beneficial in terms of reduced size, weight, power and cost (SWAP-C). The most common HgCdTe IR detector architecture is the P+n heterostructure photodiode (where a capital letter indicates a wide band gap relative to the active layer or "AL"). A variant of this architecture, the P+N-n-N-N heterostructure photodiode, should have a near identical photo-response to the P+n heterostructure, but with significantly lower dark diffusion current. The P+N-n-N-N heterostructure utilizes a very low doped AL, surrounded on both sides by wide-gap layers. The low doping in the AL, allows the AL to be fully depleted, which drastically reduces the Auger recombination rate in that layer. Minimizing the Auger recombination rate reduces the intrinsic dark diffusion current, thereby increasing Top. Note when we use the term "recombination rate" for photodiodes, we are actually referring to the net generation and recombination of minority carriers (and corresponding dark currents) by the Auger process. For these benefits to be realized, these devices must be intrinsically limited and well passivated. The focus of this proceeding is on studying the fundamental physics of the intrinsic dark currents in ideal P+N-n-N-N heterostructures, namely Auger recombination. Due to the complexity of these devices, specifically the presence of multiple heterojunctions, numerical device modeling techniques must be

  15. N-P Co-Limitation of Primary Production and Response of Arthropods to N and P in Early Primary Succession on Mount St. Helens Volcano

    Science.gov (United States)

    Bishop, John G.; O'Hara, Niamh B.; Titus, Jonathan H.; Apple, Jennifer L.; Gill, Richard A.; Wynn, Louise

    2010-01-01

    Background The effect of low nutrient availability on plant-consumer interactions during early succession is poorly understood. The low productivity and complexity of primary successional communities are expected to limit diversity and abundance of arthropods, but few studies have examined arthropod responses to enhanced nutrient supply in this context. We investigated the effects of nitrogen (N) and phosphorus (P) addition on plant productivity and arthropod abundance on 24-yr-old soils at Mount St. Helens volcano. Methodology/Principal Findings We measured the relative abundance of eight arthropod orders and five families in plots that received N, P, or no nutrients for 3–5 years. We also measured plant % cover, leaf %N, and plant diversity. Vegetation responded rapidly to N addition but showed a lagged response to P that, combined with evidence of increased N fixation, suggested P-limitation to N availability. After 3 yrs of fertilization, orthopterans (primarily Anabrus simplex (Tettigoniidae) and Melanoplus spp (Acrididae)) showed a striking attraction to P addition plots, while no other taxa responded to fertilization. After 5 yrs of fertilization, orthopteran density in the same plots increased 80%–130% with P addition and 40% with N. Using structural equation modeling, we show that in year 3 orthopteran abundance was associated with a P-mediated increase in plant cover (or correlated increases in resource quality), whereas in year 5 orthopteran density was not related to cover, diversity or plant %N, but rather to unmeasured effects of P, such as its influence on other aspects of resource quality. Conclusions/Significance The marked surprising response to P by orthopterans, combined with a previous observation of P-limitation in lepidopteran herbivores at these sites, suggests that P-mediated effects of food quantity or quality are critical to insect herbivores in this N-P co-limited primary successional system. Our results also support a previous

  16. An extended range neutron rem counter

    International Nuclear Information System (INIS)

    Birattari, C.; Nuccetelli, C.; Pelliccioni, M.; Silari, M.

    1990-01-01

    Extensive Monte Carlo calculations have been carried out to assess the possibility of extending the sensitivity of a neutron rem counter of the Andersson-Braun type up to several hundred MeV. The validity of the model adopted has first been checked by comparing with experimental data the calculated response curve and the angular dependence of the sensitivity for a well known commercial rem counter. Next, a number of modifications to the configuration of the moderator-attenuator have been investigated. The response functions and angular distributions produced by two simple solutions yielding an instrument with a sensitivity extended up to 400 MeV are presented. The response of the original rem counter and of its two modified versions to nine test spectra has also been calculated. The resulting instrument is transportable rather than portable, but the availability of an extended range neutron survey meter would be of great advantage at medium and high energy particle accelerator facilities. (orig.)

  17. The cross section measurement for the reactions of 48,46Ti(n,p) 48,46Sc, 50Ti(n, α)47Ca and 58Ni (n, 2n)57Ni, 58Ni(n,p)58m+gCo

    International Nuclear Information System (INIS)

    Yuan Junqian; Wang Yongchang; Kong Xiangzhong; Yang Jingkang

    1992-01-01

    The cross sections for the 50 Ti(n, α) 47 Ca, 46 Ti(n, p) 46 Sc, 48 Ti(n, p) 48 Sc and 58 Ni(n, 2n) 57 Ni, 58 Ni(n, p) 58m+g Co reactions have been measured by using the activation method relative to the cross sections of the 27 Al(n, α) 24 Na reaction in the neutron energy range of 13.50-14.81 MeV. The neutron energies were determined by the cross section ratios of the 90 Zr(n, 2n) 89m+g Zr and 93 Nb(n, 2n) 92m Nb reactions. The results obtained are compared with the published and to be published data of several authors

  18. Polarization-enhanced InGaN/GaN-based hybrid tunnel junction contacts to GaN p-n diodes and InGaN LEDs

    Science.gov (United States)

    Mughal, Asad J.; Young, Erin C.; Alhassan, Abdullah I.; Back, Joonho; Nakamura, Shuji; Speck, James S.; DenBaars, Steven P.

    2017-12-01

    Improved turn-on voltages and reduced series resistances were realized by depositing highly Si-doped n-type GaN using molecular beam epitaxy on polarization-enhanced p-type InGaN contact layers grown using metal-organic chemical vapor deposition. We compared the effects of different Si doping concentrations and the addition of p-type InGaN on the forward voltages of p-n diodes and light-emitting diodes, and found that increasing the Si concentrations from 1.9 × 1020 to 4.6 × 1020 cm-3 and including a highly doped p-type InGaN at the junction both contributed to reductions in the depletion width, the series resistance of 4.2 × 10-3-3.4 × 10-3 Ω·cm2, and the turn-on voltages of the diodes.

  19. A gridded air counter for measuring exoelectrons

    International Nuclear Information System (INIS)

    Nagase, Makoto; Chiba, Yoshiya; Kirihata, Humiaki.

    1980-01-01

    A gridded air counter with a quenching circuit is described, which serves to detect low-energy electrons such as thermionic electrons, photoelectrons and exoelectrons emitted into the atmospheric air. The air counter consists of a loop-shaped anode and two grids provided for quenching the gas discharge and for protecting the electron emitter from the positive ion bombardment. The quenching circuit with a high input sensitivity of 5 mV detects the initiation gas discharge caused by an incident electron and immediately supplies a rectangular wave pulse of 300 V in amplitude and of more than 3 msec in width to the quenching grid near the anode. Simultaneously, the voltage of the suppressor grid is brought down and kept at -30 V against the earthed sample for the same period of time. Performance of the gridded air counter was examined by use of photoelectrons emitted from an abraded aluminum plate. The quenching action was successfully accomplished in the anode voltage range from 3.65 to 3.95 kV. The photoelectrons emitted into the atmosphere could be counted stably by use of this counter. (author)

  20. Helium-air counter flow in rectangular channels

    International Nuclear Information System (INIS)

    Fumizawa, Motoo; Tanaka, Gaku; Zhao, Hong; Hishida, Makoto; Shiina, Yasuaki

    2004-01-01

    This paper deals with numerical analysis of helium-air counter flow in a rectangular channel with an aspect ratio of 10. The channel has a cross sectional area of 5-50 mm and a length of 200 mm. The inclination angle was varied from 0 to 90 degree. The velocity profiles and concentration profiles were analyzed with a computer program [FLUENT]. Following main features of the counter flow are discussed based on the calculated results. (1) Time required for establishing a quasi-steady state counter flow. (2) The relationship between the inclination angle and the flow patterns of the counter flow. (3) The developing process of velocity profiles and concentration profiles. (4) The relationship between the inclination angle of the channel and the velocity profiles of upward flow and the downward flow. (5) The relationship between the concentration profile and the inclination angle. (6) The relationship between the net in-flow rate and the inclination angle. We compared the computed velocity profile and the net in-flow rate with experimental data. A good agreement was obtained between the calculation results and the experimental results. (author)

  1. Photocatalytic degradation of p,p'-DDT under UV and visible light using interstitial N-doped TiO₂.

    Science.gov (United States)

    Ananpattarachai, Jirapat; Kajitvichyanukul, Puangrat

    2015-01-01

    1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (or p,p'-DDT) is one of the most persistent pesticides. It is resistant to breakdown in nature and cause the water contamination problem. In this work, a major objective was to demonstrate the application of N-doped TiO2 in degradation and mineralization of the p,p'-DDT under UV and visible light in aqueous solution. The N-doped TiO2 nanopowders were prepared by a simple modified sol-gel procedure using diethanolamine (DEA) as a nitrogen source. The catalyst characteristics were investigated using XRD, SEM, TEM, and XPS. The adsorption and photocatalytic oxidation of p,p'-DDT using the synthesized N-doped TiO2 under UV and visible light were conducted in a batch photocatalytic experiment. The kinetics and p,p'-DDT degradation performance of the N-doped TiO2 were evaluated. Results show that the N-doped TiO2 can degrade p,p'-DDT effectively under both UV and visible lights. The rate constant of the p,p'-DDT degradation under UV light was only 0.0121 min(-1), whereas the rate constant of the p,p'-DDT degradation under visible light was 0.1282 min(-1). Under visible light, the 100% degradation of p,p'-DDT were obtained from N-doped TiO2 catalyst. The reaction rate of p,p'-DDT degradation using N-doped TiO2 under visible light was sixfold higher than that under UV light. According to Langmuir-Hinshelwood model, the adsorption equilibrium constant (K) for the N-doped TiO2 under visible light was 0.03078 L mg(-1), and the apparent reaction rate constant (k) was 1.3941 mg L(-1)-min. Major intermediates detected during the p,p'-DDT degradation were p,p'-DDE, o,p'-DDE, p,p'-DDD and p,p'-DDD. Results from this work can be applied further for the breakdown of p,p'-DDT molecule in the real contaminated water using this technology.

  2. A novel current mode operating beam counter based on not preamplified HPDs

    CERN Document Server

    Fujiwara, M.C.

    2002-01-01

    A novel system to monitor the intensity and the stability of a bunched beam of $\\simeq 1.2\\times 10^{7}$ antiprotons ($\\bar{p}$s) with a length of $\\simeq$ 250 ns (FWHM) and to measure its trapping efficiency in a Penning trap is described. This system operates parasitically detecting the pions from the annihilation of part of the beam in a degrader. Six plastic scintillators have been coupled from one side to six proximity focused HPDs without preamplifiers and operating in current mode. This device works in the stray field of the ATHENA magnet with no loss of efficiency; the gain can be varied from zero to a few thousands with a precision better than 0.1% and the dynamic range is larger than 8 orders of magnitude. Linearity and stability have been measured up to charge responses of 100 nC, corresponding to the beam completely dumped. The beam counter has been calibrated in two different and independent ways giving consistent results.

  3. Two-dimensional non-volatile programmable p-n junctions

    Science.gov (United States)

    Li, Dong; Chen, Mingyuan; Sun, Zhengzong; Yu, Peng; Liu, Zheng; Ajayan, Pulickel M.; Zhang, Zengxing

    2017-09-01

    Semiconductor p-n junctions are the elementary building blocks of most electronic and optoelectronic devices. The need for their miniaturization has fuelled the rapid growth of interest in two-dimensional (2D) materials. However, the performance of a p-n junction considerably degrades as its thickness approaches a few nanometres and traditional technologies, such as doping and implantation, become invalid at the nanoscale. Here we report stable non-volatile programmable p-n junctions fabricated from the vertically stacked all-2D semiconductor/insulator/metal layers (WSe2/hexagonal boron nitride/graphene) in a semifloating gate field-effect transistor configuration. The junction exhibits a good rectifying behaviour with a rectification ratio of 104 and photovoltaic properties with a power conversion efficiency up to 4.1% under a 6.8 nW light. Based on the non-volatile programmable properties controlled by gate voltages, the 2D p-n junctions have been exploited for various electronic and optoelectronic applications, such as memories, photovoltaics, logic rectifiers and logic optoelectronic circuits.

  4. Reactance and Coping Responses to Tobacco Counter-Advertisements.

    Science.gov (United States)

    Wehbe, Michelle S; Basil, Michael; Basil, Debra

    2017-07-01

    Tobacco prevention messages generally take one of three tactics: They can be educational, attack the tobacco industry, or attack particular brands. Being a smoker and smoking a particular brand may form an essential part of a person's self-identity. As such, reactance theory suggests that attack messages can unintentionally attack smokers' self-image. A 2 × 2 × 2 × 2 experiment using six different messages and 260 respondents tested whether smokers have different reactions to tobacco counter-advertisements than nonsmokers. It also examined whether attacking a smoker's brand leads to greater reactance and other maladaptive responses compared to attacking other brands. Consistent with predictions, smokers reported more maladaptive coping responses and fewer adaptive coping responses to tobacco counter-ads than nonsmokers. The study also reveals differences attributable to brand identification. These findings suggest that interventions should consider different counter-advertising tactics for smokers and nonsmokers. Similar admonitions may apply to counter-advertising strategies on other health issues.

  5. Continuous Ecosystem Stoichiometry (C:N:P) in a Large Spring-fed River Reveals Decoupled N and P Assimilatory Dynamics

    Science.gov (United States)

    Cohen, M. J.; Douglass, R. L.; Martin, J. B.; Thomas, R. G.; Heffernan, J. B.; Foster, C. R.

    2010-12-01

    Diel variation in solutes offers insight into lotic ecosystem processes. Diel variation in dissolved oxygen (DO) is the standard method to estimate aquatic primary production (C fixation). Recently, diel variation in nitrate concentration was used to infer rates and pathways of N processing. From coupled C and N measurements, stoichiometric ratios of nutrient assimilation can be obtained, and variation therein linked back to environmental drivers and ecological changes. Here we present data obtained using an in situ phosphate sensor (Cycle-P, WetLabs, Philomath OR) that permits coupled high frequency C, N and P measurements. We collected hourly samples over 3 two-week deployments in the Ichetucknee River, a large (Q ~ 10 m3 s-1), productive (GPP ~ 6 g C m-2 d-1), entirely spring-fed river in north Florida. We observed average soluble reactive P (SRP) concentrations of 44, 41 and 45 µg/L for Dec-09, Feb-10 and Apr-10, respectively, and marked diel variation that averaged 6.7±0.9 µg/L. Observed river concentrations were consistently at or below the flow-weighted average input concentration of the 6 main springs that feed the river (49 µg/L) suggesting net SRP removal over the 5 km reach. Removal from co-precipitation with calcite or Fe-oxides is unlikely since variation in Fe and Ca is smaller than, and out of phase with, P variation. Since internal stores are presumed to be at steady-state given conditions of constant discharge, the balance of P export likely occurs as organic matter. Based on discharge during each deployment, diel variation of P concentrations indicate system-wide assimilation of 1505 ± 423 g P d-1, or 8.0 ± 2.3 mg P m-2 d-1 over the 17 ha of benthic surface area. Contemporaneous measurements of DO and nitrate implied average ecosystem stoichiometry (C:N:P) of 267:14:1, consistent with production dominated by submerged aquatic macrophytes rather than algae and other microflora. Of particular interest is the observation that diel variation in

  6. Whole-body counter

    Energy Technology Data Exchange (ETDEWEB)

    Fedorov, G A; Kosterev, V V

    1975-01-24

    A counter for detecting radiation of a man (CRM) is described, which consists of two measuring converters and a recording device. In order to obtain data on spatial distribution of a gamma-radiating nuclide studied, a fixed collimator and a mobile coder made of separate slit elements are placed between the measuring converters and an object investigated.

  7. Electromagnetically Operated Counter

    Science.gov (United States)

    Goldberg, H D; Goldberg, M I

    1951-12-18

    An electromagnetically operated counter wherein signals to be counted are applied to cause stepwise rotation of a rotatable element which is connected to a suitable register. The mechanism involved consists of a rotatable armature having three spaced cores of magnetic material and a pair of diametrically opposed electromagnets with a suitable pulsing circuit to actuate the magnets.

  8. Hardware support for software controlled fast reconfiguration of performance counters

    Science.gov (United States)

    Salapura, Valentina; Wisniewski, Robert W.

    2013-06-18

    Hardware support for software controlled reconfiguration of performance counters may include a plurality of performance counters collecting one or more counts of one or more selected activities. A storage element stores data value representing a time interval, and a timer element reads the data value and detects expiration of the time interval based on the data value and generates a signal. A plurality of configuration registers stores a set of performance counter configurations. A state machine receives the signal and selects a configuration register from the plurality of configuration registers for reconfiguring the one or more performance counters.

  9. Talousveden pH-säädön optimointi

    OpenAIRE

    Elo, Hanne

    2009-01-01

    Tämän opinnäytetyön aiheena oli Talousveden pH-säädön optimointi. Työn tarkoituksena oli tutkia Forssan Vesihuoltolaitoksella raakaveden pH:n säätöä ja tutustua STEL-80A vedenkäsittelylaitteen toimintaan. Raakaveden pH:n säätökokeita tehtiin eri vahvuisilla lipeä- ja soodaliuoksilla. STEL-80A vedenkäsittelylaite tuottaa ruokasuolasta klooria ja lipeää, joita voidaan käyttää veden desinfiointiin ja pH-säätöön. STEL-80A vedenkäsittelylaitteella tehtiin kokeita eri virran voimakkuuksilla, joiden...

  10. Output pulse height distribution of the GM counters

    International Nuclear Information System (INIS)

    Zhang Songshou; Xiong Jianping

    1995-01-01

    The GM counters are the radiation detectors most in use. It has special advantages compared with other detectors. This paper introduces the output pulse height distribution of the GM counters, gives the measuring instruments and methods. The measuring results, some discussions, and useful conclusion are given as well

  11. 'Miniskirt' counter array at CDF II

    International Nuclear Information System (INIS)

    Artikov, A.; Artikov, A.

    2006-01-01

    Full text: Muon detection is fundamental for the most of the interesting analyses at CDF. At the course of Run II, the collaboration expects to collect hundreds of t t-bar decays yielding a muon as well as several million B-hadron events involving J/ψ → μ + μ - decays. Muon detection is also of fundamental importance in the study of W-boson properties and in the search for Higgs production associated with W or Z bosons. Considerable effort therefore went into extending the muon detector coverage for Run II, which started in March 2001. The CDF II muon detector system consists of multiple layers of drift chambers and scintillation counters, which span the pseudorapidity (|η|) range between 0 and 1.5. Detectors spanning different ranges have different geometries, and the muon scintillation counter system includes subsystems in the regions that have come to be known as the 'central' (0 pe for WLS fiber readout is smaller than for conventional readout, we can also expect an increase in the statistical contribution to the overall uncertainty. Our first concern, before adopting this solution, was therefore to ascertain that the mean timing resolution obtained under these conditions was adequate. The modifications, testing and installation of these counters within the CDF Upgrade Project are described in detail. The timing characteristics of MSX' counters are also investigated using cosmic muons. The measurements show that the time resolution does not exceed 2.2 ns. (author)

  12. Responding to Cyber Jihad: Towards an Effective Counter Narrative

    Directory of Open Access Journals (Sweden)

    Bibi van Ginkel

    2015-03-01

    Full Text Available “Who is in control of the narrative?” is the mantra that now echoes in the hallways of the EU’s headquarters in Brussels. Spurred in part by large-scale jihadist propaganda, approximately 20,000 people from 50 countries have joined the fight in Iraq and Syria. So far, authorities in their countries of origin have not been able to address the jihadist radicalisation messages transmitted via the internet and social media. Many new initiatives were recently announced, however, including the establishment of a European counter-narrative centre in Brussels. Research Fellow Dr. Bibi van Ginkel analyses the role of the internet and social media in processes of radicalisation. It offers an outline of the various aspects of the jihadist narrative, in order better to understand what message needs to be countered. The counter-actions against this cyber jihad can take different forms. Parallel to the way in which advertisement campaigns are tailored to sell products to a certain target group, strategic communication should take into account how a number of recurring elements play a role in the counter-messaging. The understanding of who the target group is, what jihadist narrative is used and how that message can be countered, who the credible messenger should be, and what medium can best be used to deliver the message are all relevant questions that can only be answered in a context-specific manner. The Research Paper concludes with several recommendations on how the recently announced new European counter-narrative centre can effectively contribute to the already diverse landscape of counter-narrative initiatives.

  13. Programas de conciencia pública y prevención

    Directory of Open Access Journals (Sweden)

    . USIS

    2015-01-01

    Full Text Available Dossier Comunicación y Drogas. Las campañas de conciencia pública son vitales para el éxito de los programas de reducción de la demanda. Su propósito es hacer que el público comprenda los peligros de consumo de drogas y promover la participación pública en la guerra contra ellas. Estos programas pueden ser bastante efectivos en la creación de un clima que desaliente el uso ilegal de las drogas.

  14. Countering the ‘Natural’ Organizational Self on Social Media

    DEFF Research Database (Denmark)

    Johansen, Trine Susanne

    2017-01-01

    , challenge and contradict organizational self-narration in light of market place skepticism and cynicism. The study identifies three strategies of counter-narrativizing (authenticity, legitimacy and irony) based on juxtaposing pairs of opposites. Moreover, it suggests counter-narration to be a natural......Using narrative as a theoretical and methodological lens, this study explores digital processes of organizational identity construction in the intersection between organization and market.The purpose is to understand the ways in which online interactions produce counter-narratives that contrast...

  15. Report on Activities and Programs for Countering Proliferation and NBC Terrorism. Volume 1. Executive Summary

    Science.gov (United States)

    2011-05-01

    protect our homeland. Protect our economic vitality through enhanced security of the U.S. transportation sector. Work with foreign counterparts...34,597 garments. Since FY09, the Joint Service Aircrew Mask-Rotary Wing (JSAM-RW), Mask Protection Unit-6/P ( MPU -6/P) Apache attack helicopter...the political, economic , cultural, and other security issues related to counterproliferation. Counter Proliferation. Encourage CP professionals

  16. Sources of Brazil's Counter-Hegemony

    Directory of Open Access Journals (Sweden)

    Marcos Aurelio Guedes de Oliveira

    2010-01-01

    Full Text Available There have been two key initiatives taken in the last two decades in Brazil to create a counter-hegemonic project for the country. One initiative resulted from Brazil's business community and high-level State bureaucracy and aimed at forming a regional economic and political bloc that would guarantee and enlarge a relative independence from the hegemonic powers. The other resulted from the emergence of the new unionist movement in São Paulo and from the formation of Partido dos Trabalhadores and aimed at promoting radical democratization and reducing social exclusion. Both initiatives have created policies and changes that have converged to enhance Brazil's counter-hegemonic position as a regional and emerging power.

  17. Study of the rearrangement of N-alkylanilines to P-aminoalkylbencene. III. N-n-propil-l-14{sup C} aniline; Estudio de la transposicion de N-Alquilanilinas a p-Aminoalquibenceno mediante 14{sup C}. III. N-n Propilanilina

    Energy Technology Data Exchange (ETDEWEB)

    Molera, J M; Gamboa, J M; Val del Cob, M; Ortin, N

    1964-07-01

    The rearrangement of N-n-propyl aniline to p-amino propylbenzene has been studied at 250 degree centigrade using several catalysts: CoCl{sub 2}, ZnCl{sub 2} and HBr. N-propyl-1-14{sup C}-aniline has been synthesized from sodium propionate-1-14{sup C} through conversion to n-propyl-1-14{sup C}-iodide and further reaction with aniline. After the rearrangement and among the reaction products both p-aminopropylbenzene and p-aminoisopropylbencene were found. To determine the 14{sup C} position in both the starting aniline and reaction products two degradation schemes are followed. In the light of experimental evidence a mechanism is set forth based on the assumption of an organic cation as intermediate. (Author) 13 refs.

  18. Quasi-Birth-Death Processes, Tree-Like QBDs, Probabilistic 1-Counter Automata, and Pushdown Systems

    NARCIS (Netherlands)

    K. Etessami (Kousha); D.K. Wojtczak (Dominik); M. Yannakakis

    2010-01-01

    textabstractWe begin by observing that (discrete-time) Quasi-Birth-Death Processes (QBDs) are equivalent, in a precise sense, to probabilistic 1-Counter Automata (p1CAs), and both Tree-Like QBDs (TL-QBDs) and Tree-Structured QBDs (TS-QBDs) are equivalent to both probabilistic Pushdown Systems

  19. Description of the manufacture of a Geiger-Muller counter with window

    International Nuclear Information System (INIS)

    Granados, C. E.

    1959-01-01

    Total details about the manufacture elements in counter fabrication and the way of obtention are described as well as total indications useful in the installation process and filling of the counter. The appropriate materials and precautions that might be adopted in order to obtain counters with uniform operation and good characteristics, are described. Counters are of brass, with thin mica or aluminium windows and operate at 1100 V approximately with a slope lower than 5 % 1100 V. (Author)

  20. The Counter Terrorist Classroom: Religion, Education, and Security

    Science.gov (United States)

    Gearon, Liam

    2013-01-01

    The article identifies international cases--from the United States, Europe, and the United Nations--of an emergent interface of religion, education, and security. This is manifest in the uses of religion in education to counter religious extremism, the notional "counter terrorist classroom." To avoid an over-association of extremism with…

  1. Counter-Buffing: A Visual Criticism of Guerrilla Advertising

    Science.gov (United States)

    Lauzon, Robb Conrad; Cooke, Laquana

    2017-01-01

    This article addresses and explores hip-hop's reclamation of space using transit as a public bulletin. It is situated within counter-publics discourse and couched in the theoretical frameworks offered by visual rhetorical theory. This article also discusses hip-hop counter-publics through guerrilla advertising by former graffiti artists, SKI and…

  2. The IFIN-HH triple coincidence liquid scintillation counter

    CSIR Research Space (South Africa)

    Razdolescu, AC

    2006-10-01

    Full Text Available at IFIN-HH using a 3 H standard. The performances of the IFIN-HH TDCR counter was checked against the measurement results of the TDCR counters of CSIR NML (South Africa), RC (Poland) and LNHB (France). A set of ready-to-measure Ni-63 sources in liquid...

  3. Gobierno abierto en bibliotecas públicas: planeación estratégica y el valor público

    Directory of Open Access Journals (Sweden)

    Jennifer Alejandra Voutssás Lara

    2017-01-01

    Full Text Available La información no es la única que ha cambiado sus modelos a través de las herramientas digitales, sino que la misma sociedad se transforma constantemente en nuevos modelos y relaciones sociales. Esto ha obligado a las instituciones públicas a replantear también su labor en cuanto a la oferta de servicios a los ciudadanos, por lo que ha planteado un modelo basado en la administración de empresas privadas para una mejor administración en el ámbito público y optimización de los servicios que se ofrecen. Esta investigación ofrece un panorama conceptual del gobierno abierto, los conceptos de planeación estratégica y valor público para ejemplificar cómo fueron implementados en las bibliotecas públicas que atienden ahora a ciudadanos en ejercicio principalmente del derecho a la información y, a su vez, permitiendo el ejercicio de otros derechos fundamentales. Para ello, fue utilizada como metodología a través del análisis documental de fuentes directas sobre gobierno abierto a nivel mundial y de instituciones públicas internacionales que vigilan este derecho; así como casos en diversas bibliotecas públicas en Estados Unidos donde se llevaron estrategias de gobierno abierto en bibliotecas públicas. Finalmente, se consideraron las fuentes indirectas; por ejemplo, información no referente a estos conceptos, pero que ejemplifican el valor público y la planeación estratégica de las bibliotecas públicas en México y que, por medio del encadenamiento deductivo, complementan la comprensión del gobierno abierto en las bibliotecas como instituciones públicas y proponer nuevas estrategias de valor público en estos espacios.

  4. Organotin(IV Derivatives of 2-Acetylpyridine-N(4-Phenylthiosemicarbazone, HAP4P, and 2-Hydroxyacetophenone-N(4-Phenylthiosemicarbazone, H2DAP4P: Crystal and Molecular Structure of [SnMe2(DAP4P] and [SnBu2(DAP4P

    Directory of Open Access Journals (Sweden)

    Sousa Gerimário F. de

    2001-01-01

    Full Text Available The reactions of 2-acetylpyridine-N(4-phenylthiosemicarbazone, HAP4P, and 2-hydroxyacetophenone-N(4-phenylthiosemicarbazone, H2DAP4P, with R4-mSnXm (m = 2, 3; R = Me, nBu, Ph and X = Cl, Br led to the formation of hexa- and penta-coordinated organotin(IV complexes, which were studied by microanalysis, IR, ¹H-NMR and Mössbauer spectroscopies. The molecular structures of [SnMe2(DAP4P] and [Sn nBu2(DAP4P] were determined by single-crystal X-ray diffraction studies. In the compounds [SnClMe2(AP4P] and [SnBrMe2(AP4P], the deprotonated ligand AP4P- is N,N,S-bonded to the Sn(IV atoms, which exhibit strongly distorted octahedral coordination. The structures of [SnMe2(DAP4P] and [Sn nBu2(DAP4P] revealed that the DAP4P2- anion acts as a O,N,S-tridentate ligand. In these cases, the Sn(IV atoms adopt a strongly distorted trigonal bipyramidal configuration where the azomethine N and the two C atoms are on the equatorial plane while the O and the S atoms occupy the axial positions.

  5. Picosecond-precision multichannel autonomous time and frequency counter

    Science.gov (United States)

    Szplet, R.; Kwiatkowski, P.; RóŻyc, K.; Jachna, Z.; Sondej, T.

    2017-12-01

    This paper presents the design, implementation, and test results of a multichannel time interval and frequency counter developed as a desktop instrument. The counter contains four main functional modules for (1) performing precise measurements, (2) controlling and fast data processing, (3) low-noise power suppling, and (4) supplying a stable reference clock (optional rubidium standard). A fundamental for the counter, the time interval measurement is based on time stamping combined with a period counting and in-period two-stage time interpolation that allows us to achieve wide measurement range (above 1 h), high precision (even better than 4.5 ps), and high measurement speed (up to 91.2 × 106 timestamps/s). The frequency is measured up to 3.0 GHz with the use of the reciprocal method. Wide functionality of the counter includes also the evaluation of frequency stability of clocks and oscillators (Allan deviation) and phase variation (time interval error, maximum time interval error, time deviation). The 8-channel measurement module is based on a field programmable gate array device, while the control unit involves a microcontroller with a high performance ARM-Cortex core. An efficient and user-friendly control of the counter is provided either locally, through the built-in keypad or/and color touch panel, or remotely, with the aid of USB, Ethernet, RS232C, or RS485 interfaces.

  6. Dimensions of Counter-Narratives

    DEFF Research Database (Denmark)

    2019-01-01

    The book welcomes proposals for chapter contributions on a wide array of topics related to the narratological notion of counter-narratives. By way of example, the topic has hitherto been treated by disciplines and subjects such as literature studies, organization studies, corporate communication...

  7. Study on (n,2n) and (n,p) reactions of strontium nucleus

    Energy Technology Data Exchange (ETDEWEB)

    Yiğit, Mustafa, E-mail: mustafayigit@aksaray.edu.tr [Aksaray University, Department of Physics, Faculty of Arts and Science, Aksaray (Turkey); Tel, Eyyup [Osmaniye Korkut Ata University, Department of Physics, Faculty of Arts and Science, Osmaniye (Turkey)

    2015-11-15

    Highlights: • The cross sections for (n,2n) and (n,p) nuclear reactions on {sup 84,86,88,90}Sr target nuclei have been investigated. • The codes ALICE/ASH, PCROSS, CEM03.01, and cross section systematics are carried out in the calculations. • Cross section calculations are given at projectile energy range from the threshold up to 30 MeV. • Obtained results are compared with each other, experimental data, and ENDF/B-VII.1 and TENDL-2014 libraries. - Abstract: The cross sections for (n,2n) and (n,p) nuclear reactions on {sup 84,86,88,90}Sr target nuclei up to 30 MeV from threshold have been investigated. The determination of the cross sections has been done employing the codes ALICE/ASH, PCROSS, CEM03.01 which taking into consideration compound and precompound emissions. Calculations have been performed by using the Weisskopf Ewing model (WEM) of compound reaction mechanism, and the Hybrid model (HM), Geometry Dependent Hybrid model (GDHM) and Full Exciton model (FEM) of precompound reaction mechanism, and Cascade Exciton model (CEM) including Cascade interactions, and the empirical and semi-emipirical systematics. In order to test the theoretical nuclear models, the data obtained from the excitation function calculations are discussed and compared with available experimental values, ENDF/B-VII.1 and TENDL-2014 libraries. Finally the new cross section results calculated in the present paper may be useful for nuclear energy applications.

  8. Technical Note: Characterization of a static thermal-gradient CCN counter

    Directory of Open Access Journals (Sweden)

    G. P. Frank

    2007-06-01

    Full Text Available The static (parallel-plate thermal-gradient diffusion chamber (SDC was one of the first instruments designed to measure cloud condensation nuclei (CCN concentrations as a function of supersaturation. It has probably also been the most widely used type of CCN counter. This paper describes the detailed experimental characterization of a SDC CCN counter, including calibration with respect to supersaturation and particle number concentration. In addition, we investigated the proposed effect of lowered supersaturation because of water vapor depletion with increasing particle concentration. The results obtained give a better understanding why and in which way it is necessary to calibrate the SDC CCN counter. The calibration method is described in detail and can, in parts, be used for calibrations also for other types of CCN counters.

    We conclude the following: 1 it is important to experimentally calibrate SDC CCN counters with respect to supersaturation, and not only base the supersaturation on the theoretical description of the instrument; 2 the number concentration calibration needs to be performed as a function of supersaturation, also for SDC CCN counter using the photographic technique; and 3 we observed no evidence that water vapor depletion lowered the supersaturation.

  9. The (n,p) reaction as a probe of nuclear structure

    International Nuclear Information System (INIS)

    Jackson, K.P.; Celler, A.

    1988-08-01

    An account is given of some results of studies of the (n,p) reaction on nuclear targets at TRIUMF. The (n,p) reaction, inducing spin flip transitions in isospin space, appears to exhibit a unique sensitivity to certain aspects of nuclear structure. The TRIUMF facility is the first to exploit the (n,p) reaction as a detailed probe of nuclear structure at energies above 65 MeV. In the (n,p) reaction Fermi transitions are absent, but there is a dramatic impact on Gamow-Teller and other collective transactions. Some nuclear transition matrix elements can be estimated on the basis of (n,p) measurements. Experiments have been carried out at TRIUMF on Li 6 , Fe 5 4, and Zr 9 0 targets. The calibration of the (n,p) reaction as a probe of the Gamow-Teller strength B + GT has been achieved for three targets. (L.L.) (45 refs., 10 figs.)

  10. Electroluminescence from a n-ZnO/p-GaN hybrid LED

    Energy Technology Data Exchange (ETDEWEB)

    Behrends, Arne; Bakin, Andrey; Waag, Andreas [Institute of Semiconductor Technology, Hans-Sommer Str. 66, 38106 Braunschweig (Germany); Kwack, Ho-Sang; Dang, Le Si [Institut Neel, CNRS-UJF, 25, rue des Martyrs, 38042 Grenoble (France)

    2010-06-15

    In this work we report on the fabrication and characterization of a n-ZnO/p-GaN heterojunction LED. The p-GaN layer was fabricated using MOCVD on Al{sub 2}O{sub 3} with Mg as the acceptor whereas the ZnO nanostructures were grown in a very simple vapor transport system without any additionally doping. Room temperature electroluminescence (EL) measurements show green deep band emission centered at 2.3 eV which is clearly visible with the naked eye when the structure is forward biased. Cathodoluminescence mapping was performed to explain the absence of the band edge emission in the EL spectrum. (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  11. Investigation of thermometrical characteristics of p+–n-GaP diodes

    Directory of Open Access Journals (Sweden)

    Sypko N. I.

    2008-12-01

    Full Text Available The method of reception of p+–n-diode epitaxial structures of GaP from liquid phase is developed. In the temperature range of 80—520 K thermometric and current-voltage characteristics of test models of diode temperature sensors are measured and their basic technical parameters are determined. Perspectivity of developed GaP-diodes application as sensitive elements of high-temperature sensor is shown.

  12. Possibility of semiconductor counters application for internal contamination measurement of whole human body

    International Nuclear Information System (INIS)

    Cunic, O.; Orlic, M.; Bek-Uzarov, Dj.; Pavlovic, S.; Pavlovic, R.

    1997-01-01

    The possibility of high resolution semiconductor counters application in 'Vinca' Whole Body Counter for direct beta-gamma internal contamination measurement are discussed, assuming the following relevant characteristics: efficiency, resolution and counter price. A comparison with appropriate characteristics of NaI(Tl) crystal used in 'Vinca' WBC is treated. It is evident that the scintillation counters have the higher detection efficiency, but HPGe counters having much better resolution and recently lowest prices are also acceptable to join the existing NaI(Tl) counters with the HPGe counters in the same time, allow better spectral analyses of the human body activity and additionally more precise estimation of the equivalent doses rate which is generally a essential problem in WBC measurements. (author)

  13. Variable dead time counters: 2. A computer simulation

    International Nuclear Information System (INIS)

    Hooton, B.W.; Lees, E.W.

    1980-09-01

    A computer model has been developed to give a pulse train which simulates that generated by a variable dead time counter (VDC) used in safeguards determination of Pu mass. The model is applied to two algorithms generally used for VDC analysis. It is used to determine their limitations at high counting rates and to investigate the effects of random neutrons from (α,n) reactions. Both algorithms are found to be deficient for use with masses of 240 Pu greater than 100g and one commonly used algorithm is shown, by use of the model and also by theory, to yield a result which is dependent on the random neutron intensity. (author)

  14. Effects of understory vegetation and litter on plant nitrogen (N, phosphorus (P, N:P ratio and their relationships with growth rate of indigenous seedlings in subtropical plantations.

    Directory of Open Access Journals (Sweden)

    Jun Wang

    Full Text Available Establishing seedlings in subtropical plantations is very important for forest health, succession and management. Information on seedling nutrient concentrations is essential for both the selection of suitable indigenous tree species to accelerate succession of the established plantation and sustainable forest management. In this study, we investigated the concentrations of nitrogen ([N], phosphorus ([P], and N:P ratio in leaves, stems and roots of seedlings of three indigenous tree species (Castanopsis chinensis, Michelia chapensis and Psychotria rubra transplanted with removing or retaining understory vegetation and litter at two typical subtropical forest plantations (Eucalyptus plantation and native species plantation. We also measured the relative growth rate (RGR of seedling height, and developed the relationships between RGR and leaf [N], [P] and N:P ratio. Results showed that treatments of understory vegetation and associated litter (i.e. removal or retained generally had no significant effects on leaf [N], [P], N:P ratio and RGR of the transplanted tree seedlings for the experimental period. But among different species, there were significant differences in nutrient concentrations. M. chapensis and P. rubra had higher [N] and [P] compared to C. chinensis. [N] and [P] also varied among different plant tissues with much higher values in leaves than in roots for all indigenous species. RGR of indigenous tree seedlings was mostly positively correlated with leaf [N] and [P], but negatively correlated with leaf N:P ratio. Considering the low [P] and high N:P ratio observed in the introduced indigenous tree seedlings, we propose that the current experimental plantations might be P limited for plant growth.

  15. Inclusive π+d →pp ) process and the η N scattering length

    Science.gov (United States)

    Garcilazo, Humberto

    2018-02-01

    The cross section of the inclusive process π+d →pp ) is calculated as a function of the η p invariant mass when the detected proton is moving in the forward direction. The incident pion has a momentum of plab=898.47 MeV/c for which the η p pair are left at rest in the laboratory system which allows one to study the effect of the η p →η p final-state interaction in the region of the N (1535 ) S11 resonance. The sensitivity of the inclusive cross section to different parametrizations of the η N final-state interaction is discussed.

  16. Evaluación de la gestión privada del servicio público educativo en Medellín

    Directory of Open Access Journals (Sweden)

    Jorge Hugo Barrientos

    2007-06-01

    Full Text Available La alcaldía de Medellín emprendió en 2002 un programa de cobertura educativa dirigido a jóvenes en edad escolar en lugares donde la oferta escolar pública era reducida. El programa consistió en dar en concesión colegios de propiedad estatal a entidades educativas privadas. El objetivo de este trabajo es evaluar el impacto del programa de concesión en dos frentes, el desempeño académico, la deserción y la reprobación de los alumnos. La evaluación se hace comparando individuos, en colegios en concesión, quienes son muy parecidos a aquellos que atendieron colegios públicos. Los resultados muestran que los estudiantes en colegios en concesión han tenido un desempeño inferior a sus pares en colegios públicos, así como mayores tasas de deserción y reprobación.

  17. Evaluación de la gestión privada del servicio público educativo en Medellín

    Directory of Open Access Journals (Sweden)

    Jorge Barrientos

    2007-01-01

    Full Text Available La alcaldía de Medellín emprendió en 2002 un programa de cobertura educativa dirigido a jóvenes en edad escolar en lugares donde la oferta escolar pública era reducida. El programa consistió en dar en concesión colegios de propiedad estatal a entidades educativas privadas. El objetivo de este trabajo es evaluar el impacto del programa de concesión en dos frentes, el desempeño académico, la deserción y la reprobación de los alumnos. La evaluación se hace comparando individuos, en colegios en concesión, quienes son muy parecidos a aquellos que atendieron colegios públicos. Los resultados muestran que los estudiantes en colegios en concesión han tenido un desempeño inferior a sus pares en colegios públicos, así como mayores tasas de deserción y reprobación.

  18. The research on the failure regularity of GM counter tubes

    International Nuclear Information System (INIS)

    Li Jiyuan; Huai Guangli; Xie Bo; Zhang Hao

    2002-01-01

    The reliability of GM counter tubes should be described by useful time before failure-life and failure rate during life. A new method to study the failure regularity of GM counter tubes is advanced and adopted. The essential point of the method is that after the GM counter tubes of the instruments in use is tested, both the performance parameters and other information of the GM counter tubes and the instruments collected are recorded. Then database is created. Failure criterion is ascertained. The GM counter tubes are inspected to determine whether they are failure. Failure mode should be decided if the GM counter tubes failure. The GM counter tubes with the same useful year come together to make up a subsample. According to the relevant information, the number of the subsample is restored to the number of the sample that initially put into use. Then the number of failure sample is counted and at the same time the distribution of failure mode is got. The parameter m, γ, t 0 of Weibull distribution function are calculated with method of linear fit. Thus mean life, failure rate and other character values are obtained. Using this method, useful life and failure rate are determined. The conclusion is that the useful life is 18-20 years and the failure rate is 5 x 10 -6 and 4 x 10 -6 /h respectively during the course

  19. On timing properties of the SRPO-304 proportional counters

    International Nuclear Information System (INIS)

    Gusev, A.A.; Pugacheva, G.I.

    1979-01-01

    Data of measurements of the signal delay time and the time of development of the discharge in a proportional counter filled with 90% Xe + 10% CH 4 mixture at 0.3 atm are presented. The measurements were carried out on muons of cosmic rays. Signal delay distribution for the proportional counter are given relative to the time of passage through it of a charged particle. The data obtained shows that the average delay time is 0.8 μs when a particle passes near the counter centre, whereas when it passes near its side wall the average delay time is 1.5 μs. The investigation of the discharge development time distribution was carried out for two values of the discriminator threshold: 6 and 20 keV. It was determined that the discharge development time distribution depends but little on the place of particle passage in a counter. The average discharge development time is 1.5 μs, with the maximum time beina 4.3 μs. It is shown that the resolution time of logical circuits will be near 4 μs when the counter is combined with scintillation detectors

  20. Microchip Coulter particle counter

    DEFF Research Database (Denmark)

    Larsen, Ulrik Darling; Blankenstein, Gert; Branebjerg, J.

    1997-01-01

    This paper presents a micro device employing the Coulter principle for counting and sizing of living cells and particles in liquid suspension. The microchip Coulter particle counter (μCPC) has been employed in a planar silicon structure covered with glass, which enables detailed observation during...

  1. New proportional counter assembly in Gliwice 14C laboratory

    International Nuclear Information System (INIS)

    Moscicki, W.; Zastawny, A.

    1977-01-01

    The design and parameters are described of a proportional counter for low level counting. The cathode tube 80 mm in diameter and 30 cm in length is made of pure copper. The anode is a tungsten wire 0.05 mm in diameter. The cathode tube is surrounded by a cylindrical ring container with mercury. The total volume of the counter is 1.5 l and it is filled with carbon dioxide. At a pressure of 1 at of CO 2 the counter background is 4.20+-0.05 cpm and contemporary 14 C net effect 10.22+-0.10 cpm; at a pressure of 2 at of CO 2 the background is 4.40+-0.05 cpm and the contemporary 14 C net effect 20.53+-10 cpm. The efficiency of the proportional counter is 88% in both cases. (J.B.)

  2. Study of the 26Al(n,p)26Mg and 26Al(n,α)23Na reactions using the 27Al(p,p')27Al inelastic scattering reaction

    International Nuclear Information System (INIS)

    Benamara, S; De Séréville, N; Hammache, F; Stefan, I; Roussel, P; Ancelin, S; Assié, M; Guillot, J; Le Crom, B; Lefebvre, L; Adsley, P; Laird, A M; Barton, C; Diget, C; Fox, S; Coc, A; Deloncle, I; Hamadache, C; Kiener, J; Lefebfre-Schuhl, A

    2016-01-01

    26 Al was the first cosmic radioactivity ever detected in the galaxy as well as one of the first extinct radioactivity observed in refractory phases of meteorites. Its nucleosynthesis in massive stars is still uncertain mainly due to the lack of nuclear information concerning the 26 Al(n,p) 26 Mg and 26 Al(n,α) 23 Na reactions. We report on a single and coincidence measurement of the 27 Al(p,p') 27 Al(p) 26 Mg and 27 Al(p,p') 27 Al(α) 23 Na reactions performed at the Orsay TANDEM facility aiming at the spectroscopy study of 27 Al above the neutron threshold. Fourteen states are observed for the first time within 350 keV above the 26 Al+n threshold. (paper)

  3. Proportional counter with a wire-anode lying on the dielectric surface

    International Nuclear Information System (INIS)

    Strelkov, A.V.

    1983-01-01

    Proportional coUnter with wire-anode lying on the dielectric surface is described. The result of the accumulation of charges on the dielectric surface immediately near the wire-anode surface is that such a counter possesses electrostatic memory relative to distribution of the gas amplification coefficient along the anode. SUch a distribution can be received for example by means of irradiation by the neutrons or the γ-rays. The disposition of the wire-anode on the convex dielectric surface allows one to make the ring-shaped counters or the nonplane proportional chambers practically of any profile. However, the energy resolution of the counter with anode on the dielectric is worse than the resolution of counter with free anode particularly at the large gas amplification coefficient

  4. Controls over foliar N:P ratios in tropical rain forests.

    Science.gov (United States)

    Townsend, Alan R; Cleveland, Cory C; Asner, Gregory P; Bustamante, Mercedes M C

    2007-01-01

    Correlations between foliar nutrient concentrations and soil nutrient availability have been found in multiple ecosystems. These relationships have led to the use of foliar nutrients as an index of nutrient status and to the prediction of broadscale patterns in ecosystem processes. More recently, a growing interest in ecological stoichiometry has fueled multiple analyses of foliar nitrogen:phosphorus (N:P) ratios within and across ecosystems. These studies have observed that N:P values are generally elevated in tropical forests when compared to higher latitude ecosystems, adding weight to a common belief that tropical forests are generally N rich and P poor. However, while these broad generalizations may have merit, their simplicity masks the enormous environmental heterogeneity that exists within the tropics; such variation includes large ranges in soil fertility and climate, as well as the highest plant species diversity of any biome. Here we present original data on foliar N and P concentrations from 150 mature canopy tree species in Costa Rica and Brazil, and combine those data with a comprehensive new literature synthesis to explore the major sources of variation in foliar N:P values within the tropics. We found no relationship between N:P ratios and either latitude or mean annual precipitation within the tropics alone. There is, however, evidence of seasonal controls; in our Costa Rica sites, foliar N:P values differed by 25% between wet and dry seasons. The N:P ratios do vary with soil P availability and/or soil order, but there is substantial overlap across coarse divisions in soil type, and perhaps the most striking feature of the data set is variation at the species level. Taken as a whole, our results imply that the dominant influence on foliar N:P ratios in the tropics is species variability and that, unlike marine systems and perhaps many other terrestrial biomes, the N:P stoichiometry of tropical forests is not well constrained. Thus any use of N:P

  5. Effects of the inversion layer thickness and 10B distribution in it on the characteristics of ion-doped semiconductor neutron counters

    International Nuclear Information System (INIS)

    Diasamidze, Eh.M.; Solov'ev, Yu.A.; Shmakov, A.N.

    1984-01-01

    The technique for calculating the dependence of energy spectrum of the 10 B(n, α) 7 Li reaction products in the thickness of the inversion layer in a semiconductor counter fabricated using the diffusion method is proposed. The inversion layer is formed as a result of the 10 B ion implantation into n-type silicon. The cases of uniform and Gaussian distributions of 10 B impurity are considered. Corrections for neutron fluence calculation by α-peak, taking into account α-particle absorption in the inversion layer are obtained. It is concluded that the suggested calculational technique can be used for semiconductor counters fabricated by the diffusion method

  6. Electrical transport through Pb(Zr,Ti)O3 p-n and p-p heterostructures modulated by bound charges at a ferroelectric surface: Ferroelectric p-n diode

    Science.gov (United States)

    Watanabe, Yukio

    1999-05-01

    Current through (Pb,La)(Zr,Ti)O3 ferroelectrics on perovskite semiconductors is found to exhibit diode characteristics of which polarity is universally determined by the carrier conduction-type semiconductors. A persisting highly reproducible resistance modulation by a dc voltage, which has a short retention, is observed and is ascribed to a band bending of the ferroelectric by the formation of charged traps. This interpretation is consistent with a large relaxation current observed at a low voltage. On the other hand, a reproducible resistance modulation by a pulse voltage, which has a long retention, is observed in metal/(Pb,La)(Zr,Ti)O3/SrTiO3:Nb but not in metal/(Pb,La)(Zr,Ti)O3/(La,Sr)2CuO4 and is attributed to a possible band bending due to the spontaneous polarization (P) switching. The observed current voltage (IV) characteristics, the polarity dependence, the relaxation, and the modulation are explicable, if we assume a p-n or a p-p junction at the ferroelectric semiconductor interface (p: hole conduction type, n: electron conduction type). The analysis suggests that an intrinsically inhomogeneous P (∇P) near the ferroelectric/metal interface is likely very weak or existing in a very thin layer, when a reaction of the metal with the ferroelectric is eliminated. Additionally, the various aspects of transport through ferroelectrics are explained as a transport in the carrier depleted region.

  7. Lessons from History for Counter-Terrorism Strategic Communications

    Directory of Open Access Journals (Sweden)

    Haroro J. Ingram

    2016-06-01

    Full Text Available Drawing on the Counter-terrorism Strategic Communication (CTSC Project’s research paper “A Brief History of Propaganda during Conflict“, this Policy Brief lays out the key policy-relevant lessons for developing effective counter-terrorism strategic communications. It presents a framework of interrelated macro-, mezzo- and micro-level considerations for maximizing the efficacy of not just a strategic communications campaign but message design. Historical examples are drawn upon to illustrate their practical application. The Policy Brief concludes by analysing four key strategic-policy principles arguing that a counter-terrorism strategic communications campaign is more likely to be successful if it is based on the cumulative effects of a multidimensional messaging strategy.

  8. 4-GHz counters bring synthesizers up to speed

    Science.gov (United States)

    Lee, F.; Miller, R.

    1984-06-01

    The availability of digital IC counters built on GaAs makes direct frequency division in microwave synthesizers possible. Four GHz is the highest clock rate achievable in production designs. These devices have the ability to drive TTL/CMOS logic, and the counter can be connected directly to single-chip frequency synthesizers controllers. A complete microwave sythesizer is formed by two chips and a voltage-controlled oscillator (VCO). The advantages of GaAs are discussed along with flip-flop basics, aspects of device fabrication, and the characteristics of GaAs MESAFETs. Attention is given to a GaAs prescaler usable for direct conversion, four kinds of flip-flops in a divide-by-two mode, and seven-stage binary ripple counters.

  9. Interference effects in inclusive charge-exchange p+p→n+X and n+p→p+X reactions at intermediate energies

    International Nuclear Information System (INIS)

    Gareev, F.A.; Ratis, Yu.L.; Korovin, P.P.; Strokovskij, E.A.; Vaagen, J.S.

    1992-01-01

    The formalism of Feynman diagrams to describe charge-exchange reactions p+p→n+X and n+p→p+X on a free proton target taking into account spectator and decay modes in the π+ρ+g'-model have used. It is shown that the interference between these modes depends on the set of vertex function parameters used. It is also shown that the constructive interference of the Δ + and Δ 0 -isobars is important. 22 refs.; 10 figs

  10. Anodic photodissolution of n-InP, under electroless conditions

    International Nuclear Information System (INIS)

    Debiemme-Chouvy, Catherine; Quennoy, Anne

    2004-01-01

    In the presence of α-SiMo 12 O 40 4- ions dissolved in acidic solution and under laser irradiation, the electroless photoetching of n-type InP is achieved. At the laser impact, the semiconductor is oxidized while SiMo 12 O 40 4- species are reduced. The shape of the pit formed, due to the photoanodic dissolution of the material, depends on the experimental conditions, notably on the presence or not of Cl - ions in the medium. It can have either a Gaussian shape or a flat bottom. To specify the charge transfer which occurs at the n-InP/solution illuminated interface, some electrochemical studies were performed on n- and p-type InP electrodes. In fact, the reduction of SiMo 12 O 40 4- ions occurs by capture of electrons from the InP conduction band. Considering the energetic situation at the InP/electrolyte interface and some electrochemical results, it is concluded that the electron transfer from InP to SiMo 12 is mediated by surface states. The influence of Cl - ions on the n-InP photodissolution process is also discussed

  11. (p,n) reaction at intermediate energy

    International Nuclear Information System (INIS)

    Goodman, C.D.

    1979-01-01

    The use of the (p,n) reaction in exploring effective interactions is reviewed. Some recent data on self-conjugate nuclei taken at the Indiana University Cyclotron Facility (IUCF) are presented, and the differences between low- and high-energy data are emphasized. Experimental problems and techniques used are briefly described. It is concluded that forward-angle (p,n) spectra at energies greater than 100 MeV are dominated by Gamow-Teller (GT) transitions, while Fermi transitions (IAS transitions) dominate near 45 MeV. Prominent GT transitions are expected from a pion-exchange interaction, and it is expected that OPEP is the dominant component of the interaction in the energy range of 100 to 200 MeV. 27 figures, 2 tables

  12. Analysis of Cherenkov counter efficiencies for E691

    International Nuclear Information System (INIS)

    Cremaldi, L.; Elliott, J.; Gibney, M.; Nauenberg, U.

    1985-01-01

    A program is outlined which simulates Cherenkov counters. The program can compute the effect of the magnetic field on the efficiencies of Cherenkov counters. It also tells what cone to mirror distance gives the highest collection efficiency and at which target position should the laser be placed to represent the direction of the actual Cherenkov light the mirror sees

  13. X-ray proportional counter for the Viking Lander

    International Nuclear Information System (INIS)

    Glesius, F.L.; Kroon, J.C.; Castro, A.J.; Clark, B.C.

    1978-01-01

    A set of four sealed proportional counters with optimized energy response is employed in the X-ray fluorescence spectrometer units aboard the two Viking Landers. The instruments have provided quantitative elemental analyses of soil samples taken from the Martian surface. This paper discusses the design and development of these miniature proportional counters, and describes their performance on Mars

  14. High efficiency GaN-based LEDs using plasma selective treatment of p-GaN surface

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young-Bae; Naoi, Yoshiki; Sakai, Shiro [Department of Electrical and Electronic Engineering, University of Tokushima, 2-1 Minami-josanjima, Tokushima 770-8506 (Japan); Takaki, Ryohei; Sato, Hisao [Nitride Semiconductor Co., Ltd., 115-7 Itayajima, Akinokami, Seto-cho, Naruto, Tokushima 771-0360 (Japan)

    2003-11-01

    We have studied a new method of increasing the extraction efficiency of a GaN-based light-emitting diode (LED) using a plasma surface treatment. In this method, prior to the evaporation of a semitransparent p-metal, the surface of a p-GaN located beneath a p-pad is selectively exposed to a nitrogen plasma in a reactive ion etching (RIE) chamber. The electrical characteristics of the plasma treated p-GaN remarkably changes its resistivity into semi-insulator without any parasitic damage. Since the LEDs with a new method have no light absorption in a p-pad region, a higher optical power can be extracted compared to a conventional LEDs without plasma selective treatment on the p-GaN surface. (copyright 2003 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  15. Micro Raman and photoluminescence spectroscopy of nano-porous n and p type GaN/sapphire(0001).

    Science.gov (United States)

    Ingale, Alka; Pal, Suparna; Dixit, V K; Tiwari, Pragya

    2007-06-01

    Variation of depth within a single etching spot (3 mm circular diameter) was observed in nanoporous GaN epilayer obtained on photo-assisted electrochemical etching of n and p-type GaN. The different etching depth regions were studied using microRaman and PL(yellow region) for both n-type and p-type GaN. From Raman spectroscopy, we observed that increase in disorder is accompanied by stress relaxation, as depth of etching increases for n-type GaN epilayer. This is well corroborated with scanning electron microscopy results. Contrarily, for p-type GaN epilayer we found that for minimum etching depth, stress in epilayer increases with increase in disorder. This is understood with the fact that as grown p-type GaN is more disordered compared to n-type GaN due to heavy Mg doping and further disorder leads to lattice distortion leading to increase in stress.

  16. Construction techniques and working principles of external cathode Geiger-Mueller counters

    International Nuclear Information System (INIS)

    Sevegnani, Francisco Xavier

    1996-01-01

    In this paper, the construction technique and working principles of the external cathode Geiger-Mueller counter are described in detail. During the analysis of the behavior of these counters a new phenomena was observed, related to an increase int he background rate with the applied voltage. The experiments have also shown that the pulse amplitude of those counters decreases exponentially with the counting rate. The counters built with the techniques described in this paper has shown plateaus of about 1400 V with slope of 0,8%/100 V. (author)

  17. Sculptured platinum nanowire counter electrodes for dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyeonseok [Department of Electrical Engineering, Pennsylvania State University, University Park 16802 (United States); Horn, Mark W., E-mail: MHorn@engr.psu.edu [Department of Engineering Science and Mechanics, Pennsylvania State University, University Park 16802-6812 (United States)

    2013-07-01

    Sculptured platinum nanowire thin films were formed by oblique angle electron beam evaporation with a 5° vapor incidence angle and incorporated as counter electrodes for dye-sensitized solar cells (DSSCs). For the comparison of the performance, bare fluorine doped tin oxide, planar Pt electrodes and counter electrodes treated with chloroplatinic acid were prepared. The sculptured Pt nanowire electrodes showed five times lower charge transfer resistance (0.121 [Ω∗cm{sup 2}]) than that of Pt planar electrode (0.578 [Ω∗cm{sup 2}]) and when the Pt nanowire electrodes are treated with an H{sub 2}PtCl{sub 6} solution have more than ten times lower charge transfer resistance (0.04025 [Ω∗cm{sup 2}]). Moreover, Pt nanowire films used as a counter electrode lead to enhancement in current density and efficiency in comparison with Pt planar counter electrodes. The conversion efficiency with planar electrodes was 5.1 [%] while the efficiency of DSSC with platinum nanowire counter electrodes reached to 5.63 [%] under AM 1.5 illumination. - Highlights: • Pt sculptured thin films (STFs) fabricated by electron beam evaporator. • The STFs featured higher roughness and lower charge transfer resistance. • Improved performance of dye-sensitized solar cells by Pt STFs counter electrodes.

  18. Measurements of differential cross sections and polarization parameters for the π-p →π0n reactions from 1.8 GeV/c to 3.0 GeV/c

    International Nuclear Information System (INIS)

    Hemmi, Yasuo

    1977-01-01

    Experimental study has just begun at KEK (Japan) to measure the differential cross section and the polarization parameter for the π - p→π 0 n reaction from 1.8 GeV/c to 3.0 GeV/c. This lecture note describes on the purpose and the method of the measurement. The schematic diagram of the experimental arrangement for the π - p→π 0 n reaction measurement is given. For the detection of neutrons, plastic scintillation counter hodoscopes were used. For the detection of electrons, lead glass Cherenkov counters were used. Some preliminary results of the experiment and the efficiency of detection are presented. (Aoki, K.)

  19. Development of a Mobile Ice Nucleus Counter

    Energy Technology Data Exchange (ETDEWEB)

    Kok, Gregory [Droplet Measurement Technologies, Boulder, CO (United States); Kulkarni, Gourihar [Droplet Measurement Technologies, Boulder, CO (United States)

    2014-07-10

    An ice nucleus counter has been constructed. The instrument uses built-in refrigeration systems for wall cooling. A cascade refrigeration system will allow the cold wall to operate as low as -70°C, and a single stage system can operate the warm wall at -45C. A unique optical particle counter has been constructed using polarization detection of the scattered light. This allows differentiation of the particles exiting the chamber to determine if they are ice or liquid.

  20. A recoil-proton fast-neutron counter telescope

    International Nuclear Information System (INIS)

    Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R.; Galeazzi, G.; Bressanini, G.

    1981-01-01

    A recoil-proton neutron counter telescope is described composed of a solid-state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time of flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV. (author)

  1. The GlueX Start Counter and Beam Asymmetry$\\Sigma$ in Single $\\pi^{0}$ Photoproduction

    Energy Technology Data Exchange (ETDEWEB)

    Pooser, Eric [Florida Intl Univ., Miami, FL (United States)

    2016-03-26

    The GlueX experiment aims to study meson photoproduction while utilizing the coherent bremsstrahlung technique to produce a 9 GeV linearly polarized photon beam incident on a liquid H2 target. A Start Counter detector was fabricated to properly identify the accelerator electron beam buckets and to provide accurate timing information. The Start Counter detector was designed to operate at photon intensities of up to 108 γ/s in the coherent peak and provides a timing resolution ~300 ps so as to provide successful identification of the electron beam buckets to within 99% accuracy. Furthermore, the Start Counter detector provides excellent solid angle coverage, ~ 90% of 4π hermeticity, and a high degree of segmentation for background rejection. It consists of a cylindrical array of 30 scintillators with pointed ends that bend towards the beam at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were selected as the readout system. An initial measurement of the beam asymmetry Sigma in the exclusive reaction γ$\\vec{p}$→ π0p, where π0 → γ has been carried out utilizing the GlueX spectrometer during the Spring 2015 commissioning run. The tagged photon energies ranged from 2.5≤ Eγ ≤ 3.0 GeV in the coherent peak. These measurements were then compared to the world data set and show remarkable agreement with only two hours of physics production running.

  2. Organic p-n heterostructures and superlattices

    Energy Technology Data Exchange (ETDEWEB)

    Kowarik, Stefan [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Hinderhofer, Alexander; Gerlach, Alexander; Schreiber, Frank [Institut fuer Angewandte Physik, Tuebingen (Germany); Osso, Oriol [MATGAS 2000 A.I.E., Esfera UAB, Barcelona (Spain); Wang, Cheng; Hexemer, Alexander [Advanced Light Source, Berkeley, CA (United States)

    2009-07-01

    For many applications of organic semiconductors two components such as e.g. n and p-type layers are required, and the morphology of such heterostructures is crucial for their performance. Pentacene (PEN) is one of the most promising p-type molecular semiconductors and recently perfluoro-pentacene (PFP) has been identified as a good electron conducting material for complementary circuits with PEN. We use soft and hard X-ray reflectivity measurements, scanning transmission X-ray microscopy (STXM) and atomic force microscopy for structural investigations of PFP-PEN heterostructures. The chemical contrast between PEN and PFP in STXM allows us to determine the lateral length scales of p and n domains in a bilayer. For a superlattice of alternating PFP and PEN layers grown by organic molecular beam deposition, X-ray reflectivity measurements demonstrate good structural order. We find a superlattice reflection that varies strongly when tuning the X-ray energy around the fluorine edge, demonstrating that there are indeed alternating PFP and PEN layers.

  3. Dual-wavelength electroluminescence from an n-ZnO/p-GaN heterojunction light emitting diode

    International Nuclear Information System (INIS)

    Tsai, Bor-Sheng; Chiu, Hung-Jen; Chen, Tai-Hong; Lai, Li-Wen; Ho, Chai-Cheng; Liu, Day-Shan

    2015-01-01

    Highlights: • The LEDs fabricated by 450 °C- and 700 °C-annealed n-ZnO/p-GaN heterojunction structures were investigated. • The structure annealed at 700 °C emitted yellowish light composed of the dual-wavelength radiations centered at 420 and 610 nm. • The long-wavelength radiation was attributed to emerge from the deep-level emission and the Ga–O interlayer emission. - Abstract: We investigated the electro-optical properties of light emitting diodes (LEDs) fabricated by using the n-ZnO/p-GaN heterojunction structures annealed at 450 °C and 700 °C, in vacuum ambient. A dominant near-UV emission at approximately 420 nm was observed from the LED fabricated by the 450 °C-annealed n-ZnO/p-GaN heterojunction structure, whereas that of the structure annealed at 700 °C emitted a yellowish light composed of the dual-wavelength emissions centered at 420 and 610 nm. The mechanism responsible for the broad long-wavelength radiation was ascribed to the transitions associated with both the deep-level emissions due to the activation of the native defects on the n-ZnO side surface and the formation of the Ga–O interlayer resulting from the in-diffusion of oxygen atoms to the p-GaN side surface of the n-ZnO/p-GaN interface.

  4. Inclusive Sigma- photoproduction on the neutron via the reaction gamma n (p) -→ K+ Sigma- (p)

    International Nuclear Information System (INIS)

    Jorn Langheinrich; Ana Lima; Barry Berman

    2006-01-01

    The analysis described here is part of a comprehensive survey of the elementary strangeness photoproduction cross sections on the nucleon. The six elementary strangeness reactions are γn → K 0 Λ and γp → K + Λ γn → K 0 Σ 0 and γp → K + Σ 0 γn → K + Σ - and γp → K 0 Σ| +

  5. Calibration and Monte Carlo modelling of neutron long counters

    CERN Document Server

    Tagziria, H

    2000-01-01

    The Monte Carlo technique has become a very powerful tool in radiation transport as full advantage is taken of enhanced cross-section data, more powerful computers and statistical techniques, together with better characterisation of neutron and photon source spectra. At the National Physical Laboratory, calculations using the Monte Carlo radiation transport code MCNP-4B have been combined with accurate measurements to characterise two long counters routinely used to standardise monoenergetic neutron fields. New and more accurate response function curves have been produced for both long counters. A novel approach using Monte Carlo methods has been developed, validated and used to model the response function of the counters and determine more accurately their effective centres, which have always been difficult to establish experimentally. Calculations and measurements agree well, especially for the De Pangher long counter for which details of the design and constructional material are well known. The sensitivit...

  6. Inhibition of Pain and Pain-Related Brain Activity by Heterotopic Noxious Counter-Stimulation and Selective Attention in Chronic Non-Specific Low Back Pain.

    Science.gov (United States)

    Ladouceur, Alexandra; Rustamov, Nabi; Dubois, Jean-Daniel; Tessier, Jessica; Lehmann, Alexandre; Descarreaux, Martin; Rainville, Pierre; Piché, Mathieu

    2017-10-10

    The aim of the present study was to assess inhibition of pain and somatosensory-evoked potentials (SEPs) by heterotopic noxious counter-stimulation (HNCS) and by selective attention in patients with chronic non-specific LBP. Seventeen patients and age/sex-matched controls were recruited (10 men, 7 women; mean age ± SD: 43.3 ± 10.4 and 42.7 ± 11.1, respectively). On average, patients with LBP reported pain duration of 7.6 ± 6.5 years, light to moderate disability (19.3 ± 5.7/100) and low clinical pain intensity (21.8 ± 1.5/100), while pain catastrophizing, state and trait anxiety and depressive symptoms were not significantly different between groups (all p's >0.05). HNCS and selective attention had differential inhibitory effects on pain and SEP, but no difference was observed between groups. Across both groups, HNCS decreased pain (p = 0.06) as well as the N100 and the N150 components of SEP (p's selective attention only decreased pain (p attention was directed toward the HNCS stimulus (pselective attention. Importantly, this experiment was carefully designed to control for non-specific effects associated with the repetition of the test stimulus and the effect of an innocuous counter-stimulation. It remains to be determined if these results hold for patients with severe LBP and psychological symptoms or whether symptom severity may be associated with pain inhibition deficits. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.

  7. VARIACIÓN ALTITUDINAL ENTRE ESPECIES Y PROCEDENCIAS DE Pinus pseudostrobus, P. devoniana y P. leiophylla. ENSAYO DE VIVERO

    Directory of Open Access Journals (Sweden)

    Dante Castellanos-Acuña

    2013-01-01

    Full Text Available Los bosques de pino-encino de la comunidad de Nuevo San Juan, Michoacán, están dominados por Pinus pseudostrobus, P. devoniana y P. leiophylla. Los patrones de variación genética de estas especies no se conocen lo suficiente, particularmente los de P. leiophylla, lo cual limita la creación de lineamientos para el movimiento de semillas y plántulas para reforestación y su adaptación al cambio climático. Las especies se recolectaron en cuatro o cinco procedencias a lo largo de un transecto altitudinal (1,650 a 2,500 m para el establecimiento de un ensayo en vivero, con el objetivo de cuantificar la variación genética entre y dentro de las especies. La altura de la planta (tres y cinco meses de edad fue significativamente diferente (P < 0.0001 entre especies. Entre procedencias hubo diferencias significativas para P. devoniana (P < 0.0001 y P. leiophylla (P = 0.0352. La especie P. devoniana mostró un pronunciado patrón de crecimiento asociado con la altitud de origen, donde las plantas con mayor crecimiento procedían de una menor altitud. Las poblaciones de P. leiophylla fueron diferentes sólo a los tres meses de edad, sin un patrón altitudinal estadísticamente significativo. No se encontraron diferencias significativas entre poblaciones de P. pseudostrobus.

  8. Molecular gated-AlGaN/GaN high electron mobility transistor for pH detection.

    Science.gov (United States)

    Ding, Xiangzhen; Yang, Shuai; Miao, Bin; Gu, Le; Gu, Zhiqi; Zhang, Jian; Wu, Baojun; Wang, Hong; Wu, Dongmin; Li, Jiadong

    2018-04-18

    A molecular gated-AlGaN/GaN high electron mobility transistor has been developed for pH detection. The sensing surface of the sensor was modified with 3-aminopropyltriethoxysilane to provide amphoteric amine groups, which would play the role of receptors for pH detection. On modification with 3-aminopropyltriethoxysilane, the transistor exhibits good chemical stability in hydrochloric acid solution and is sensitive for pH detection. Thus, our molecular gated-AlGaN/GaN high electron mobility transistor acheived good electrical performances such as chemical stability (remained stable in hydrochloric acid solution), good sensitivity (37.17 μA/pH) and low hysteresis. The results indicate a promising future for high-quality sensors for pH detection.

  9. INTRODUCING OVER THE COUNTER COUNSELING

    Directory of Open Access Journals (Sweden)

    Nataša Bakić-Mirić

    2009-01-01

    Full Text Available A pharmacist in today’s world has a great responsibility – to help and educate patients about diverse ways for effective self-treatment. Whereas self-care is becoming increasingly popular among patients today the availability of over-the-counter medications makes it possible for patients to treat numerous conditions on their own but still under the supervision of a healthcare provider. During the pharmacist-patient encounter, the pharmacist’s obligation is to evaluate the patient’s medical condition, provide proper advice and counsel the patient on the proper course of treatment to be taken. Also by employing effective over the counter (OTC counseling as the most proper means in a pharmacist/patient communication process and, accordingly, rapport building in the OTC area, the pharmacist needs to demonstrate high energy, enthusiasm, respect, empathy, know-how of sensitive intercultural issues alongside personal appearance, body language, eye contact that all together make his/her personal “signature”. Accordingly, apart from patient education, the primary objective of OTC counseling becomes to educate pharmacists on basic principles used in assisting patients in the selection of over-the-counter (OTC products, provide examples of proper communication techniques for effective patient counseling concerning the OTC products (i.e. dosage, administration technique, storage, food and beverage interaction, monitoring etc where the pharmacist plays the key role in helping patients maximize their pharmaceutical care.

  10. About the distribution of delays in G.M counters

    International Nuclear Information System (INIS)

    Picard, E.; Rogozinski, A.

    1954-01-01

    We measure, with an oscillograph method the global time that pass between the time that a particle in a determined region of the studied counter and the answer of the amplifier associated to the counter. This delay is composed of the latency time T l and the T q delay, that result from the rise time finished of the impulse and whose value depends of the sensitivity threshold of the amplifier. The selection of (cosmic) particles generating discharge in the studied counter is obtained thanks to a telescope of two meters in coincidence whose opening is limited by a group of four counters in anti-coincidence with the first. The meter is arranged so that the median plan of the telescope crosses to a variable distance d of his axial thread. The measures have been done for different securities of the distance d and of the over-voltage V s applied to the counter. The results show that the statistical distribution of the delays is more spread especially when d is bigger and V s more reduced. The average values of the observed delays vary of 7.10 -8 s for d = 0 and V s es = 200 V, to 90.10 -8 s for d = 1,9 cm and V s = 50 V. The mobility of an free electron within the gaseous mixture filling the counter under a pressure of 10 cm.Hg was found equal: (2,1 ±0,2).10 4 cm 2 .s -1 .V -1 . (author) [fr

  11. Electrical characterization of proton irradiated p+-n-n+ Si diode

    International Nuclear Information System (INIS)

    Kim, J.H.; Lee, D.U.; Kim, E.K.; Bae, Y.H.

    2006-01-01

    Electrical characterization of p + -n-n + Si power electric diodes was done with proton irradiation. The kinetic energies of irradiated protons were 2.32, 2.55 and 2.97MeV, and for each energy condition, doses of 1x10 11 , 1x10 12 and 1x10 13 cm -2 were given. By modulating the kinetic energy, the proton penetration depth into Si crystal could be adjusted to the range of 55-90μm, and then controlled to the special depth regions such as junction region, depletion region and neutral region over the depletion layer in the p + -n-n + diode structure. Defects produced by the proton irradiation affected to electrical property of the Si diode because of their carrier trapping, and then the reverse recovery time was improved from 240 to 50ns. It appeared that the defect states with activation energies of 0.47 and 0.54eV may be responsible for the decrease of the minority carrier lifetime in the proton-irradiated diode with 2.97MeV energy and 1x10 13 cm -2 doses

  12. Microbial N and P mining regulates the effect of N deposition on soil organic matter turnover

    Science.gov (United States)

    Meyer, Nele; Welp, Gerhard; Rodionov, Andrei; Borchard, Nils; Martius, Christopher; Amelung, Wulf

    2017-04-01

    Nitrogen (N) deposition to soils has become a global issue during the last decades. Its effect on mineralization of soil organic carbon (SOC), however, is still debated. Common theories based on Liebig's law predict higher SOC mineralization rates in nutrient-rich than in nutrient-poor soils. Contrastingly, the concept of microbial N mining predicts lower mineralization rates after N deposition. The latter is explained by ceased decomposition of recalcitrant soil organic matter (SOM) as the need of microbes to acquire N from this pool decreases. As N deposition might shift the nutrient balance towards relative phosphorus (P) deficiency, it is also necessary to consider P mining in this context. Due to limited knowledge about microbial nutrient mining, any predictions of N deposition effects are difficult. This study aims at elucidating the preconditions under which microbial nutrient mining occurs in soil. We hypothesized that the occurrence of N and P mining is controlled by the current nutrient status of the soil. Likewise, soils might respond differently to N additions. To investigate this hypothesis, we conducted substrate-induced respiration measurements on soils with pronounced gradients of N and P availability. We used topsoil samples taken repeatedly from a site which was up to 7 years under bare fallow (Selhausen, Germany) and up to 4 m deep tropical forest soils (Kalimantan, Indonesia). Additional nutrient manipulations (glucose, glucose+N, glucose+P, glucose+N+P additions) were conducted to study the effect of nutrient additions. Samples were incubated for one month. We further conducted 13C labeling experiments to trace the sources of CO2 (sugar vs. SOM derived CO2) for further hints on nutrient mining. Mineralization of glucose was limited by a lack of available N in the bare fallow soil but microbes were able to slowly acquire N from previously unavailable pools. This resulted in a slightly higher release of native SOM-derived CO2 compared to N

  13. A semiconductor counter telescope for neutron reaction studies

    Energy Technology Data Exchange (ETDEWEB)

    Lalovic, B I; Ajdacic, V S [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1963-12-15

    A counter telescope consisting of two or three semiconductor counters for {delta}E/{delta}x vs. E analysis was made for studying nuclear reactions induced by 14.4 MeV neutrons. Various factors important for the telescope performance are discussed in details and some solutions for getting an optimum resolution and a low background are given. Protons, deuterons and alpha particles resulting from scattering and reactions of 14.4 MeV neutrons on deuterium, tritium, praseodymium and niobium were detected, and pulses from the counters recorded on a two-dimensional analyzer. These experiments have shown that the telescope compares favorably with other types of telescopes with regards to the upper limit of neutron flux which can be used, (DELTADELTA)x and E resolution, versatility and compactness (author)

  14. Isoelectronic Ln doping in p-GaN and its effects on InGaN light-emitting diodes

    International Nuclear Information System (INIS)

    Kim, C. S.; Cheong, H. S.; Kang, D. S.; Kim, J. Y.; Hong, C. H.; Suh, E. K.; Lee, H. J.; Cho, H. K.; Adesida, I.

    2004-01-01

    The effects of isoelectronic In doping in a Mg-doped p-GaN layer on device performance of InGaN light-emitting diodes (LED) were investigated. It was found that there was a decrease of Hall resistivity and contact resistivity in p-GaN with In doping, compared to typical Mg-doped p-GaN. Isoelectronic In doping in p-GaN seems to cause a kind of surfactant effect and/or purification effect similar to the In-doped GaN case, which exhibits a decrease of non-radiative recombination centers and an enhancement of carrier concentration. Light output power and operating voltage were improved by applying an In-doped p-GaN contact layer to the LED.

  15. Study of Stark Effect in n-doped 1.55 μm InN0.92yP1-1.92yBiy/InP MQWs

    Science.gov (United States)

    Bilel, C.; Chakir, K.; Rebey, A.; Alrowaili, Z. A.

    2018-05-01

    The effect of an applied electric field on electronic band structure and optical absorption properties of n-doped InN0.92y P1-1.92y Bi y /InP multiple quantum wells (MQWs) was theoretically studied using a self-consistent calculation combined with the 16-band anti-crossing model. The incorporation of N and Bi atoms into an InP host matrix leads to rapid reduction of the band gap energy covering a large infrared range. The optimization of the well parameters, such as the well/barrier widths, N/Bi compositions and doping density, allowed us to obtain InN0.92y P1-1.92y Bi y /InP MQWs operating at the wavelength 1.55 μm. Application of the electric field causes a red-shift of the fundamental transition energy T 1 accompanied by a significant change in the spatial distribution of confined electron density. The Stark effect on the absorption coefficient of n-doped InN0.92y P1-1.92y Bi y /InP MQWs was investigated. The Bi composition of these MQWs was adjusted for each electric field value in order to maintain the wavelength emission at 1.55 μm.

  16. Carbon Nanotubes Counter Electrode for Dye-Sensitized Solar Cells Application

    Directory of Open Access Journals (Sweden)

    Drygała A.

    2016-06-01

    Full Text Available The influence of the carbon nanotubes counter electrode deposited on the FTO glass substrates on the structure and optoelectrical properties of dye-sensitized solar cells counter electrode (CE was analysed. Carbon materials have been applied in DSSC s in order to produce low-cost solar cells with reasonable efficiency. Platinum is a preferred material for the counter electrode because of its high conductivity and catalytic activity. However, the costs of manufacturing of the platinum counter electrode limit its use to large-scale applications in solar cells. This paper presents the results of examining the structure and properties of the studied layers, defining optical properties of conductive layers and electrical properties of dye-sensitized solar cells manufactured with the use of carbon nanotubes.

  17. Importance of sequential two-step transfer process in a ΔS = 1 and ΔT = 1 inelastic transition of 14N(p, p')14N reaction

    International Nuclear Information System (INIS)

    Aoki, Y.; Kunori, S.; Nagano, K.; Toba, Y.; Yagi, K.

    1981-01-01

    Differential cross sections and vector analyzing powers for 14 N(p, p') and 14 N(p, d) reactions have been measured at E sub(p) = 21.0 MeV to elucidate the reaction mechanism and the effective interaction for the ΔS = ΔT = 1 transition in 14 N(p, p') 14 N(2.31 MeV) reaction. The data are analyzed in terms of finite-range distorted wave Borm approximation (DWBA) which include direct, knock-on exchange and (p, d)(d, p') two-step processes. Shell model wave functions of Cohen and Kurath are used. The data for the first excited state is reasonably well explained by introducing two-step process. The two-step process explains half of the experimental intensity. Moreover vector analyzing power can hardly be explained without introducing this two-step process. Vector analyzing power of protons leading to the second excited state in 14 N is better explained by introducing macroscopic calculation. The data for 14 N(p, d) 13 N(gs) reaction are well explained by a suitable choice of deuteron optical potential. Knock-on exchange contribution is relatively small. Importance of this two-step process for ΔS = ΔT = 1 transition is discussed up to 40 MeV. (author)

  18. Study of $\\pi^{-}p$ interactions with neutral final states

    CERN Document Server

    2002-01-01

    This experiment is a study of the production of neutral particles or states decaying into photons in the reaction $\\pi^{-} + p \\rightarrow M^{0} + n$ at SPS energies. \\\\ \\\\ Special attention is paid to the measurement of the production of heavy particles with hidden quantum numbers and of possible new heavy spinless states decaying into two photons. \\\\ \\\\ The large four-momentum transfer behaviour of binary processes involving known neutral mesons and the production of new meson resonances with high mass and spin will also be studied. Complex multiparticle final states will be analysed as a by-product.\\\\ \\\\ The central unit of the experimental set-up is a 4000 cell Cerenkov hodoscope spectrometer (GAMS) which allows the measurement of the momentum vector of each $\\gamma$ in a multigamma event. \\\\ \\\\ The longitudinal position of the interaction point in the liquid hydrogen target is measured by the Cerenkov light intensity. \\\\ \\\\ A guard system, made of scintillation counters and lead-glass Cerenkov counters, ...

  19. Towards a Theory of Fear Management in the Counter-Terrorism Domain

    Directory of Open Access Journals (Sweden)

    Edwin Bakker

    2014-01-01

    Full Text Available Since 9/11, the state of the art in counter-terrorism research, counter-terorism measures and counter-terrorism impacts has taken off. Nevertheless, countering terrorism as a branch of fear management is still a discipline to be developed. In this Research Paper, authors Prof. Dr. Edwin Bakker and Prof. Dr. Beatrice de Graaf attempt to lessen this gap. The Paper identifies and analyses governmental approaches to managing fear in relation to terrorist incidents. It is a stocktaking approach, offering a preliminary oversight of some central aspects and pointers on the way forward when constructing and testing such a theory.

  20. Synthesis and cathodoluminescence of Sb/P co-doped GaN nanowires

    International Nuclear Information System (INIS)

    Wang, Zaien; Liu, Baodan; Yuan, Fang; Hu, Tao; Zhang, Guifeng; Dierre, Benjamin; Hirosaki, Naoto; Sekiguchi, Takashi; Jiang, Xin

    2014-01-01

    Sb/P co-doped Gallium Nitride (GaN) nanowires were synthesized via a simple chemical vapor deposition (CVD) process by heating Ga 2 O 3 and Sb powders in NH 3 atmosphere. Scanning electron microscope (SEM), X-ray diffraction (XRD), transmission electron microscope (TEM) and energy dispersive X-ray spectroscopy (EDS) measurements confirmed the as-synthesized products were Sb/P co-doped GaN nanowires with rough morphology and hexagonal wurtzite structure. Room temperature cathodoluminescence (CL) demonstrated that an obvious band shift of GaN nanowires can be observed due to Sb/P co-doping. Possible explanation for the growth and luminescence mechanism of Sb/P co-doped GaN nanowires was discussed. Highlight: • Sb/P co-doped GaN nanowires were synthesized through a well-designed multi-channel chemical vapor deposition (CVD) process. • Sb/P co-doping leads to the crystallinity deterioration of GaN nanowires. • Sb/P co-doping caused the red-shift of GaN nanowires band-gap in UV range. • Compared with Sb doping, P atoms are more easy to incorporate into the GaN lattice

  1. Counter-diffusion and -permeation of deuterium and hydrogen through metals

    Energy Technology Data Exchange (ETDEWEB)

    Kizu, Kaname; Tanabe,; Tetsuo, [Nagoya Univ. (Japan)

    1998-03-01

    The first experiments for counter-diffusion and -permeation of deuterium and hydrogen through palladium were performed. Deuterium permeation rates against D{sub 2} pressure were measured under the condition where hydrogen permeated to opposite direction by supplying H{sub 2} gas at the permeated side of D{sub 2}. It was found that not a small amount of deuterium was clearly permeated even if the deuterium pressure was much smaller than the hydrogen pressure. Deuterium permeation rate was gradually reduced by increasing the counter H permeation. The deuterium permeation rate under the counter H permeation is well represented by a simple model in which the ratio of the deuterium permeation rates with and without the counter H permeation was proportional to the fractional concentration of deuterium in the bulk. As increasing the hydrogen counter flow, however, the deuterium permeation rate deviates from the model. This means that adsorption (absorption) of D{sub 2} from gas phase is inhibited and surface recombination of deuterium is blocked by hydrogen. (author)

  2. The effect of counter-trading on competition in electricity markets

    International Nuclear Information System (INIS)

    Dijk, Justin; Willems, Bert

    2011-01-01

    In a competitive electricity market, nodal pricing is the most efficient way to manage congestion. Counter-trading is inefficient as it gives the wrong long term signals for entry and exit of power plants. However, in a non-competitive market, additional entry will improve the competitiveness of the market, and will increase social benefit by reducing price-cost margins. This paper studies whether the potential pro-competitive entry effects could make counter-trading more efficient than nodal pricing. We find that this is unlikely to be the case, and expect counter-trading to have a negative effect on overall welfare. The potential benefits of additional competition (more competitive prices and lower production cost) do not outweigh the distortions (additional investment cost for the entrant, and socialization of the congestion cost to final consumers). - Research highlights: → 'Counter-trading' and 'nodal pricing' manage congestion in electric grids. → Nodal pricing gives superior locational prices. → Counter-trading induces extra investments in regions with a production surplus. → Extra investments improve competition, but are expected to be socially inefficient.

  3. Irradiated fuel bundle counter

    International Nuclear Information System (INIS)

    Campbell, J.W.; Todd, J.L.

    1975-01-01

    The design of a prototype safeguards instrument for determining the number of irradiated fuel assemblies leaving an on-power refueled reactor is described. Design details include radiation detection techniques, data processing and display, unattended operation capabilities and data security methods. Development and operating history of the bundle counter is reported

  4. Acción pública y consumo colaborativo. Regulación de las viviendas de uso turístico en el contexto p2p

    Directory of Open Access Journals (Sweden)

    Nicolás Alejandro Guillén Navarro

    2016-01-01

    Full Text Available En el marco del denominado turismo colaborativo, las viviendas de uso turístico están revolucionando el modelo de alojamiento a nivel mundial. Apoyadas por su comercialización a través de los entornos p2p y el vacío legal al respecto, en los últimos años han adquirido tal importancia que por parte de los poderes públicos se ha visto necesario su regulación y así poner freno a aspectos tan problemáticos como la economía sumergida que genera dicha actividad o la competencia desleal sobre otros establecimientos de alojamiento turístico reglados. Propietarios, turistas, sector hotelero y Administraciones públicas han generado un interesante debate acerca de las implicaciones y repercusiones asociadas a las viviendas de uso turístico y hasta qué punto debe ejercerse un control sobre ellas. De ahí que este estudio trate de analizar todos estos puntos de vista y dé a conocer cómo se está haciendo frente a este fenómeno en España.

  5. Evaluation and improvement of cross section accuracy for most important dosimetry reactions 27Al(n,p), 56Fe(n,p) and 237Np(n,f) including covariance data

    International Nuclear Information System (INIS)

    Zolotarev, K.I.

    2004-02-01

    New evaluations of cross sections and their uncertainties for dosimetry reactions 27 Al(n,p) , 56 Fe(n,p) and 237 Np(n,f) have been carried out in the frame work of IAEA Research Contract No. 11372/RB. Data files prepared for this reactions in the ENDF-6 format may be consider as candidates for the new International Reactor Dosimetry File: IRDF-2002. (author)

  6. Constant sensitivity circuit for solid state nuclear radiation counters

    International Nuclear Information System (INIS)

    Kronenberg, S.; Erkkila, B.

    1985-01-01

    The utilization of solid state counters in tactical radiological instruments for measuring intensities and doses of fallout gamma rays offers advantages over Geiger-Mueller (GM) counters such as a much wider dynamic range and low operating voltages. Their very small size is suitable for use in miniaturized equipment. However, these devices have a serious problem if used in a mixed, fast neutron/gamma environment such as is encountered e.g. in a battlefield where tactical nuclear weapons are used and neutrons, prompt, initial gammas and fallout gammas are killing factors of comparable importance. Exposure to fast neutrons reduces seriously their sensitivity. This makes the solid state counters at this time unacceptable for use in Army tactical surveillance equipment and in other applications where according to requirements the performance must not be impaired by exposure to fast neutrons. It seems to be possible to reduce to some extent this neutron generated damage by improving the crystal counters

  7. Contribution to the study of πN→π1π2N reactions with creation of an intermediate N*sub(3/2) (1236) isobare from 0.4 to 1.5 GeV

    International Nuclear Information System (INIS)

    Merlo, J.P.

    1976-10-01

    The one pion production reaction π + p→π + pπ 0 has been studied up to 1.5 GeV. The π 0 angular distribution measured by counter techniques has been compared to bubble chamber data. Angular distributions are interpreted in the hypothesis of formation of the intermediate N*sub(3/2) (1236) isobar. Angular distributions for isobar production and decay in one pion production reactions πN→π 1 N* (N*→π 2 N) are calculated. π + p→π + pπ 0 experimental results are reported and analyzed. An estimation of the pion-isobar partial wave amplitudes in reaction π + p→π 0 N*sub(3/2)sup(++) (1236) has been tempted. Comparison with π + p phase shift analyses is made. Bubble chamber data for π - p→π - π + n channel are presented [fr

  8. The Trojan Horse Method as a tool to investigate low-energy resonances: the 18O(p, α)15N and 17O(p, α)14N cases

    International Nuclear Information System (INIS)

    La Cognata, M.; Sergi, M. L.; Spitaleri, C.; Cherubini, S.; Gulino, M.; Kiss, G.; Lamia, L.; Pizzone, R. G.; Romano, S.; Mukhamedzhanov, A.; Goldberg, V.; Tribble, R.; Coc, A.; Hammache, F.; Sereville, N. de; Irgaziev, B.; Tumino, A.

    2010-01-01

    The 18 O(p, α) 15 N and 17 O(p, α) 14 N reactions are of primary importance in several as-trophysical scenarios, including nucleosynthesis inside Asymptotic Giant Branch stars and oxygen and nitrogen isotopic ratios in meteorite grains. They are also key reactions to understand exotic systems such as R-Coronae Borealis stars and novae. Thus, the measurement of their cross sections in the low energy region can be crucial to reduce the nuclear uncertainty on theoretical predictions, because the resonance parameters are poorly determined. The Trojan Horse Method, in its newly developed form particularly suited to investigate low-energy resonances, has been applied to the 2 H( 18 O, α 15 N)n and 2 H( 17 O, α 14 N)n reactions to deduce the 18 O(p, α) 15 N and 17 O(p, α) 14 N cross sections at low energies. Resonances in the 18 O(p, α) 15 N and 17 O(p, α) 14 N excitation functions have been studied and the resonance parameters deduced.

  9. Analysis of counter-rotating wind turbines

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Zakkam, Vinod Arun Kumar; Sørensen, Jens Nørkær

    2007-01-01

    This paper presents a study on the performance of a wind turbine with two counter-rotating (CRWT) rotors. The characteristics of the two counter-rotating rotors are on a 3-bladed Nordtank 500 kW rotor. The analysis has been carried out by using an Actuator Line technique implemented in the Navier......-Stokes code EllipSys3D. The analysis shows that the Annual Energy Production can be increased to about 43.5 %, as compared to a wind turbine with a single rotor. In order to determine the optimal settings of the CRWT turbine, parameters such as distance between two rotors and rotational speed have been...

  10. Calibration of nuclear medicine gamma counters

    International Nuclear Information System (INIS)

    Orlic, M.; Spasic-Jokic, V.; Jovanovic, M.; Vranjes, S. . E-mail address of corresponding author: morlic@vin.bg.ac.yu; Orlic, M.)

    2005-01-01

    In this paper the practical problem of nuclear medicine gamma counters calibration has been solved by using dose calibrators CRC-15R with standard error ±5%. The samples from technetium generators have been measured both by dose calibrators CRC-15R and gamma counter ICN Gamma 3.33 taking into account decay correction. Only the linear part of the curve has practical meaning. The advantage of this procedure satisfies the requirements from international standards: the calibration of sources used for medical exposure be traceable to a standard dosimetry laboratory and radiopharmaceuticals for nuclear medicine procedures be calibrated in terms of activity of the radiopharmaceutical to be administered. (author)

  11. Development of DUPIC safeguards neutron counter

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Gil; Cha, Hong Ryul; Kim, Ho Dong; Hong, Jong Sook; Kang, Hee Young

    1999-08-01

    KAERI, in cooperation with LANL, developed DSNC (DUPIC Safeguards Neutron Counter) for safeguards implementing on DUPIC process which is under development by KAERI for direct use of spent PWR fuel in CANDU reactors. DSNC is a well-type neutron coincidence counter with substantial shielding to protect system from high gamma radiation of spent fuel. General development procedures in terms of design, manufacturing, fabrication, cold and hot test, performance test for DSNC authentication by KAERI-IAEA-LANL are described in this report. It is expected that the techniques related DSNC development and associated neutron detection and evaluation method could be applied for safeguards improvement. (Author). 20 refs., 16 tabs. 98 figs.

  12. Neutron coincidence counter for MOX fuel pins in storage trays: users' manual

    International Nuclear Information System (INIS)

    Cowder, L.; Menlove, H.

    1982-08-01

    The neutron coincidence counter for measurement of mixed-oxide fuel pins in storage trays is described. The special detector head has been designed so that the detectors, high-voltage junction boxes, and electronics are interchangeable with those of the high-level neutron coincidence counter system. This manual describes the system components and the operation and maintenance of the counter. The counter was developed at Los Alamos National Laboratory for in-plant inspection applications by the International Atomic Energy Agency

  13. Radiative lifetimes of the 2s2p2(4P) metastable levels of N III

    Science.gov (United States)

    Fang, Z.; Kwong, Victor H. S.; Parkinson, W. H.

    1993-01-01

    The radiative decay rates of N III 175 nm intersystem lines were measured in the laboratory by recording the time dependence of photon intensities emitted as the 2s2p2(4P) metastable term of N(2+) ions decay to the 2s22p(2P0) ground term. A cylindrical radio frequency ion trap was used to store the electron impact-produced N(2+) ions. The radiative decay signals were analyzed by multiexponential least-squares fits to the data. The measured radiative decay rates to the ground term are 1019(+/- 64)/s for 4P sub 1/2, 74.5(+/- 5.4)/s for 4P sub 3/2, and 308( +/- 22)/s for 4P sub 5/2. Comparisons of the measured values with theoretical values are presented.

  14. Toward an Ecologically Optimized N:P Recovery from Wastewater by Microalgae

    Science.gov (United States)

    Fernandes, Tânia V.; Suárez-Muñoz, María; Trebuch, Lukas M.; Verbraak, Paul J.; Van de Waal, Dedmer B.

    2017-01-01

    Global stores of important resources such as phosphorus (P) are being rapidly depleted, while the excessive use of nutrients has led to the enrichment of surface waters worldwide. Ideally, nutrients would be recovered from wastewater, which will not only prevent eutrophication but also provide access to alternative nutrient stores. Current state-of-the-art wastewater treatment technologies are effective in removing these nutrients from wastewater, yet they can only recover P and often in an insufficient way. Microalgae, however, can effectively assimilate P and nitrogen (N), as well as other macro- and micronutrients, allowing these nutrients to be recovered into valuable products that can be used to close nutrient cycles (e.g., fertilizer, bioplastics, color dyes, and bulk chemicals). Here, we show that the green alga Chlorella sorokiniana is able to remove all inorganic N and P present in concentrated toilet wastewater (i.e., black water) with N:P ratios ranging between 15 and 26. However, the N and P uptake by the algae is imbalanced relative to the wastewater N:P stoichiometry, resulting in a rapid removal of P but relatively slower removal of N. Here, we discuss how ecological principles such as ecological stoichiometry and resource-ratio theory may help optimize N:P removal and allow for more effective recovery of N and P from black water. PMID:28955317

  15. Toward an Ecologically Optimized N:P Recovery from Wastewater by Microalgae

    Directory of Open Access Journals (Sweden)

    Tânia V. Fernandes

    2017-09-01

    Full Text Available Global stores of important resources such as phosphorus (P are being rapidly depleted, while the excessive use of nutrients has led to the enrichment of surface waters worldwide. Ideally, nutrients would be recovered from wastewater, which will not only prevent eutrophication but also provide access to alternative nutrient stores. Current state-of-the-art wastewater treatment technologies are effective in removing these nutrients from wastewater, yet they can only recover P and often in an insufficient way. Microalgae, however, can effectively assimilate P and nitrogen (N, as well as other macro- and micronutrients, allowing these nutrients to be recovered into valuable products that can be used to close nutrient cycles (e.g., fertilizer, bioplastics, color dyes, and bulk chemicals. Here, we show that the green alga Chlorella sorokiniana is able to remove all inorganic N and P present in concentrated toilet wastewater (i.e., black water with N:P ratios ranging between 15 and 26. However, the N and P uptake by the algae is imbalanced relative to the wastewater N:P stoichiometry, resulting in a rapid removal of P but relatively slower removal of N. Here, we discuss how ecological principles such as ecological stoichiometry and resource-ratio theory may help optimize N:P removal and allow for more effective recovery of N and P from black water.

  16. Determination of the Townsend primary ionization coefficient using a parallel plate avalanche counter

    International Nuclear Information System (INIS)

    Tsumaki, Koji

    1988-01-01

    Gas multiplication factors were obtained from the observed fast pulse of a parallel plate avalache counter and the Townsend primary ionization coefficients for methane and isobutane were determined from the data over the ranges E/P = 150-228 V/cm·Torr and 183-411 V/cm·Torr, respectively. The results for methane agreed well with the values obtained by Heylen. (author)

  17. Algunas consideraciones sobre normalización en la administración pública

    Directory of Open Access Journals (Sweden)

    Rolando Bolaños Garita

    2011-01-01

    Full Text Available La Normalización es un concepto al que no podemos considerar divorciado de la Administración Pública, o exclusivo de abordaje en el campo de la Administración de Negocios. Cada día se denota con mayor fuerza el empuje que instancias como la Contraloría General de la República brindan a la estandarización de acciones o servicios en razón no solo de unificar la gestión administrativa, sino de brindar servicios a los ciudadanos bajo criterios de calidad. El peligro que visualizamos cuando se abordan temas como el aquí propuesto, es que los funcionarios públicos, que procedan a concretar acciones de Normalización, lo hagan sin tener noción o consideración del entorno y particularidades de la Administración Pública costarricense y, por el contrario, extrapolen tendencias, estrategias o incluso textos de carácter internacional y, sobre todo, anglosajón, lo que consideramos que sí echaría por tierra cualquier esfuerzo bien intencionado de mejor gestión y(o modernización pública.

  18. Counter-terrorism strategies in Indonesia, Algeria and Saudi Arabia

    NARCIS (Netherlands)

    Meijer, R.; Hasan, Noorhaidi; Hendriks, B.; Janssen, F.

    2012-01-01

    This report is the result of a year-long study, conducted from March 2010 to March 2011, of the counter-terrorist strategies of three countries: Indonesia, Algeria and Saudi Arabia. The aim of this study was to acquire insight into the counter-terrorist strategies of these countries, to analyse

  19. Design and Implementation of MOD-6 Synchronous Counter using VHDL

    Directory of Open Access Journals (Sweden)

    P. Y. Dibal

    2013-08-01

    Full Text Available This paper deals with the design of a MOD-6 synchronous counter using VHDL (VHSIC Hardware Description Language. The VHSIC stands for Very High Speed Integrated Circuit. Using this approach, the behaviour of the counter is the most important aspect of the design. In the first section, the paper introduced counters in general, and their areas of specialization, like frequency synthesizers. The synchronous counter was then introduced, stating the behaviour of the flip-flops that make the counter. The modulus of a counter was defined. In the second section, the Xilinx ISE (Integrated Simulation Environment and the ISIM (Integrated Simulator were presented and briefly described with their respective snapshots. The structure of a typical VHDL code was presented, which included LIBRARY, ENTITY, and ARCHITECTURE. Each of these structures was then briefly described. The main work in this paper was then presented. The count sequence steps were stated as . VHDL was used to model the counter to count through six steps, outputting count values according to desired steps. The hardware implementation of the design was presented, where the implementation process was described, with a supporting diagram, followed by the floor-planning technique, in which the PORTS described in the VHDL design were assigned to the physical pins of the XC3S1000 FPGA (Field Programmable Gate Array chip. The final steps of the hardware implementation process were then presented. These include bitstream generation and download to target device. The third section of the paper presented the results obtained. Simulation/timing results of the design were presented, showing the output of the counter at each state with respect to the clock signal. The result of the synthesis of the design was presented, which showed the FPGA area with the exact location of the pins on the FPGA chip. Finally, the fourth section presented the conclusion arrived at, in respect of the design that was carried

  20. Application of GM counters in the continuous monitoring of the environment

    International Nuclear Information System (INIS)

    Deme, S.

    1978-01-01

    Around critical nuclear facilities environmental control systems giving continuous information about given spots are applied. Both the fission products and the closed radiation sources released from the facilities can be most efficiently detected by their γ-radiation. From various aspects, the GM-counters proved to be the most suitable detectors for such purposes. Some questions concerning its application are discussed in more detail. The control system elaborated in the Central Research Institute of Physics contains three parallel GM-counters, a ratemeter, a scaler and a printer attached to it. High power can be centrally or locally supplied. In case of more than four measuring channels the application of a simple data collecting equipment with common electronic units is advisable. Programmable data collectors are used when alarm signals are required above a specified level. The dependence of the minimum of the detectable increase of dose rate on several parameters of the measuring system, involving the duration of the measuring cycle are discussed emphasizing the advantages of reversive scelers. (V.N.)

  1. Titanium-dioxide nanotube p-n homojunction diode

    Science.gov (United States)

    Alivov, Yahya; Ding, Yuchen; Singh, Vivek; Nagpal, Prashant

    2014-12-01

    Application of semiconductors in functional optoelectronic devices requires precise control over their doping and formation of junction between p- and n-doped semiconductors. While doped thin films have led to several semiconductor devices, need for high-surface area nanostructured devices for photovoltaic, photoelectrochemical, and photocatalytic applications has been hindered by lack of desired doping in nanostructures. Here, we show titanium-dioxide (TiO2) nanotubes doped with nitrogen (N) and niobium (Nb) as acceptors and donors, respectively, and formation of TiO2 nanotubes p-n homojunction. This TiO2:N/TiO2:Nb homojunction showed distinct diode-like behaviour with rectification ratio of 1115 at ±5 V and exhibited good photoresponse for ultraviolet light (λ = 365 nm) with sensitivity of 0.19 A/W at reverse bias of -5 V. These results can have important implications for development of nanostructured metal-oxide solar-cells, photodiodes, LED's, photocatalysts, and photoelectrochemical devices.

  2. Titanium-dioxide nanotube p-n homojunction diode

    Energy Technology Data Exchange (ETDEWEB)

    Alivov, Yahya, E-mail: y.alivov@colorado.edu, E-mail: pnagpal@colorado.edu; Ding, Yuchen; Singh, Vivek [Department of Chemical and Biological Engineering, University of Colorado Boulder, 3415 Colorado Avenue, Boulder, Colorado 80303 (United States); Nagpal, Prashant, E-mail: y.alivov@colorado.edu, E-mail: pnagpal@colorado.edu [Department of Chemical and Biological Engineering, University of Colorado Boulder, 3415 Colorado Avenue, Boulder, Colorado 80303 (United States); Materials Science and Engineering, University of Colorado Boulder, 3415 Colorado Avenue, Boulder, Colorado 80303 (United States); Renewable and Sustainable Energy Institute, University of Colorado Boulder, 2445 Kittredge Loop, Boulder, Colorado 80309 (United States)

    2014-12-29

    Application of semiconductors in functional optoelectronic devices requires precise control over their doping and formation of junction between p- and n-doped semiconductors. While doped thin films have led to several semiconductor devices, need for high-surface area nanostructured devices for photovoltaic, photoelectrochemical, and photocatalytic applications has been hindered by lack of desired doping in nanostructures. Here, we show titanium-dioxide (TiO{sub 2}) nanotubes doped with nitrogen (N) and niobium (Nb) as acceptors and donors, respectively, and formation of TiO{sub 2} nanotubes p-n homojunction. This TiO{sub 2}:N/TiO{sub 2}:Nb homojunction showed distinct diode-like behaviour with rectification ratio of 1115 at ±5 V and exhibited good photoresponse for ultraviolet light (λ = 365 nm) with sensitivity of 0.19 A/W at reverse bias of −5 V. These results can have important implications for development of nanostructured metal-oxide solar-cells, photodiodes, LED's, photocatalysts, and photoelectrochemical devices.

  3. Prescription Drugs, Over-the-Counter Drugs, Supplements and Herbal Products

    Science.gov (United States)

    ... at risk? Zika virus and pregnancy Folic acid Medicine safety and pregnancy Birth defects prevention Learn how ... the-counter drugs, supplements and herbal products Prescription drugs, over-the-counter drugs, supplements and herbal products ...

  4. Whole body counters: types, performance and uses

    International Nuclear Information System (INIS)

    Jales, R.L.C.

    1983-01-01

    The present monograph deals with Whole Counters, since its definition, evolution, performance, clinical indications and results. Scintillation crystals detection systems were described as well as scintillant solutions, plastic scintillations, and gaseous detectors, including its interplay forms and basal characteristics. Geometric arrangements of standard chair, arc and hammock, arrangements with scintillant solutions and plastic scintillations, as well as special geometric arrangements were equally commented. Clinic and experimental studies were also dealt with Whole Body Counters, giving examples with potassium, iron vitamin B 12 and albumin. (author)

  5. Measurements and systematics studies of the (n,p), (n,α) and (n,2n) reactions cross-sections at 14.5 MeV neutrons

    International Nuclear Information System (INIS)

    Osman, Khalda

    2000-01-01

    Accurate knowledge of the cross-sections for fast neutron-induced reactions utilizing the D-T reaction is important not only because of the wide spread of data observed in the literature, but also because of the world wide demand and requests for such data, in view of the increasing interest in the fusion reactor technology, which is based on the same reactions. Cross-sections are needed also for various practical purposes, including neutron activation analysis and dosimetry. In this work the (n.p), (n,2n) and (n,α) reactions cross-sections were measured at 14.5 MeV for isotopes of the elements: Cr, Ti, Ni, Co, Zr, and Mo using the activation method. The measured cross-sections were compared with recently published data. Good agreement was observed for most of the measurements. The discrepancies observed were attributed to difficulties related to the long half-life of the product nuclei and small abundances of the target isotopes. Attempts were also made to study the dependence of the (n,p), (n,2n) and (n,α) reactions cross-sections on the on the asymmetry parameter (N-Z)/A. The results confirmed the trend theoretically suggested by Levkovskii and experimentally realized by Qaim and co-workers. The isotopic dependence of (n,p) reaction cross-sections and the variation of the ration σ n ,pn ,α with Z-number of the target isotopes were also studied in this work and the results obtained were found to be in agreement with theoretical predictions. In this work studies carried out for the systematics of the (n,p), (n,2n) and (n,α) reactions cross-sections at 14 MeV neutrons and formula based on the statistical model presented, with the aim of improving the systematics of these cross-sections. Comparison of present proposed systematics were for the (n,p), (n,2n) and (n,α) reactions cross-sections with the cross-section values measured in this work was made. Good agreement was generally noted, but some discrepancies were also observed. These discrepancies were

  6. Irradiated fuel bundle counter

    International Nuclear Information System (INIS)

    Campbell, J.W.; Todd, J.L.

    1975-01-01

    The design of a prototype safeguards instrument for determining the number of irradiated fuel assemblies leaving an on-power refueled reactor is described. Design details include radiation detection techniques, data processing and display, unattended operation capabilities and data security methods. Development and operating history of the bundle counter is reported. (U.S.)

  7. A numerical model of p-n junctions bordering on surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Altermatt, P.P.; Aberle, A.G.; Jianhua Zhao; Aihua Wang; Heiser, G. [University of New South Wales, Sydney (Australia). Centre for Photovolatic Engineering

    2002-10-01

    Many solar cell structures contain regions where the emitter p-n junction borders on the surface. If the surface is not well passivated, a large amount of recombination occurs in such regions. This type of recombination is influenced by the electrostatics of both the p-n junction and the surface, and hence it is different from the commonly described recombination phenomena occurring in the p-n junction within the bulk. We developed a two-dimensional model for the recombination mechanisms occurring in emitter p-n junctions bordering on surfaces. The model is validated by reproducing the experimental I-V curves of specially designed silicon solar cells. It is shown under which circumstances a poor surface passivation, near where the p-n junction borders on the surface, reduces the fill factor and the open-circuit voltage. The model can be applied to many other types of solar cells. (author)

  8. Semiconducting ZnSnN{sub 2} thin films for Si/ZnSnN{sub 2} p-n junctions

    Energy Technology Data Exchange (ETDEWEB)

    Qin, Ruifeng [Hebei Engineering Laboratory of Photoelectronic Functional Crystals, Hebei University of Technology (HEBUT), Tianjin 300401 (China); Ningbo Institute of Material Technology and Engineering, Chinese Academy of Sciences, and Key Laboratory of Additive Manufacturing Materials of Zhejiang Province, Ningbo 315201 (China); Cao, Hongtao; Liang, Lingyan, E-mail: lly@nimte.ac.cn, E-mail: swz@hebut.edu.cn; Xie, Yufang; Zhuge, Fei; Zhang, Hongliang; Gao, Junhua; Javaid, Kashif [Ningbo Institute of Material Technology and Engineering, Chinese Academy of Sciences, and Key Laboratory of Additive Manufacturing Materials of Zhejiang Province, Ningbo 315201 (China); Liu, Caichi; Sun, Weizhong, E-mail: lly@nimte.ac.cn, E-mail: swz@hebut.edu.cn [Hebei Engineering Laboratory of Photoelectronic Functional Crystals, Hebei University of Technology (HEBUT), Tianjin 300401 (China)

    2016-04-04

    ZnSnN{sub 2} is regarded as a promising photovoltaic absorber candidate due to earth-abundance, non-toxicity, and high absorption coefficient. However, it is still a great challenge to synthesize ZnSnN{sub 2} films with a low electron concentration, in order to promote the applications of ZnSnN{sub 2} as the core active layer in optoelectronic devices. In this work, polycrystalline and high resistance ZnSnN{sub 2} films were fabricated by magnetron sputtering technique, then semiconducting films were achieved after post-annealing, and finally Si/ZnSnN{sub 2} p-n junctions were constructed. The electron concentration and Hall mobility were enhanced from 2.77 × 10{sup 17} to 6.78 × 10{sup 17 }cm{sup −3} and from 0.37 to 2.07 cm{sup 2} V{sup −1} s{sup −1}, corresponding to the annealing temperature from 200 to 350 °C. After annealing at 300 °C, the p-n junction exhibited the optimum rectifying characteristics, with a forward-to-reverse ratio over 10{sup 3}. The achievement of this ZnSnN{sub 2}-based p-n junction makes an opening step forward to realize the practical application of the ZnSnN{sub 2} material. In addition, the nonideal behaviors of the p-n junctions under both positive and negative voltages are discussed, in hope of suggesting some ideas to further improve the rectifying characteristics.

  9. Evaluation and improvement of cross section accuracy for most important dosimetry reactions 27Al(n,p), 56Fe(n,p) and 237Np(n,f) including covariance data

    Energy Technology Data Exchange (ETDEWEB)

    Zolotarev, K I [Institute of Physics and Power Engineering, Obninsk (Russian Federation)

    2004-02-01

    New evaluations of cross sections and their uncertainties for dosimetry reactions {sup 27}Al(n,p) , {sup 56}Fe(n,p) and {sup 237}Np(n,f) have been carried out in the frame work of IAEA Research Contract No. 11372/RB. Data files prepared for this reactions in the ENDF-6 format may be consider as candidates for the new International Reactor Dosimetry File: IRDF-2002. (author)

  10. Configuración del paisaje, espacio público y arte público en el Perú

    OpenAIRE

    Crousse Rastelli, Verónica

    2011-01-01

    En este artículo se discuten algunos aspectos que fueron materia de estudio en mi tesis doctoral “Reencontrando la espacialidad para el arte público en el Perú”, desarrollada en el doctorado “Espacio público y Regeneración Urbana; arte, teoría y conservación del Patrimonio” de la Universidad de Barcelona, bajo la dirección del Dr. Antoni Remesar. La tesis indaga sobre la construcción del paisaje en el Perú, y en el arte público como elemento configurador de estos paisajes. Ante el análisis de...

  11. Trinuc: a fortran program for the identification, and the energy and momentum determination of the light charged particles (p,d,t) and neutrons emitted after the absorption at the rest of negative pions in light nuclei

    International Nuclear Information System (INIS)

    Rui, R.

    1982-01-01

    Energy, momentum and missing mass spectra, angular distribution of two particles (n,n), (p,p), (n,d) and (n,t) detected in coincidence experiments, have been calculated with this program. At this moment only π - absorption reactions on 12 C nuclei have been studied, even if the program is adaptable to execute these calculations for any kind of target nucleus. The π - + 12 C experiment was performed at the triumf meson facility - Vancouver B.C., Canada -, under the supervision of prof. C. Cernigoi. The instrumental apparatus used to perform the experiment consisted of a beam telescope (ref. 1), of four large are a plastic counters NC (ref. 2) and of a large telescope plastic counter RT (ref.3). The tecniques of time of flight (TOF) e x de (only for charged particles) have been used to deduce the energy and identify the mass of the detected particles

  12. Vertically p-n-junctioned GaN nano-wire array diode fabricated on Si(111) using MOCVD.

    Science.gov (United States)

    Park, Ji-Hyeon; Kim, Min-Hee; Kissinger, Suthan; Lee, Cheul-Ro

    2013-04-07

    We demonstrate the fabrication of n-GaN:Si/p-GaN:Mg nanowire arrays on (111) silicon substrate by metal organic chemical vapor deposition (MOCVD) method .The nanowires were grown by a newly developed two-step growth process. The diameter of as-grown nanowires ranges from 300-400 nm with a density of 6-7 × 10(7) cm(-2). The p- and n-type doping of the nanowires is achieved with Mg and Si dopant species. Structural characterization by X-ray diffraction (XRD) and high-resolution transmission electron microscopy (HRTEM) indicates that the nanowires are relatively defect-free. The room-temperature photoluminescence emission with a strong peak at 370 nm indicates that the n-GaN:Si/p-GaN:Mg nanowire arrays have potential application in light-emitting nanodevices. The cathodoluminscence (CL) spectrum clearly shows a distinct optical transition of GaN nanodiodes. The nano-n-GaN:Si/p-GaN:Mg diodes were further completed using a sputter coating approach to deposit Au/Ni metal contacts. The polysilazane filler has been etched by a wet chemical etching process. The n-GaN:Si/p-GaN:Mg nanowire diode was fabricated for different Mg source flow rates. The current-voltage (I-V) measurements reveal excellent rectifying properties with an obvious turn-on voltage at 1.6 V for a Mg flow rate of 5 sccm (standard cubic centimeters per minute).

  13. Una amenaza para la escuela pública: Laicidad, privatización y segregación

    Directory of Open Access Journals (Sweden)

    Enrique Javier Díez Gutiérrez

    2014-01-01

    Full Text Available La educación pública española nunca ha llegado a romper del todo con las tres principales herencias del franquismo: confesionalidad, segregación clasista y un amplísimo sector privado costeado con fondos públicos. No obstante, se han logrado avances en el desarrollo de la red pública, con un incremento de centros y de profesorado, bajada de ratios de alumnado por aula, ampliación de la edad escolar obligatoria, escolarización casi total desde los tres años y mayor acceso a estudios superiores de las capas populares. Esta línea de conquistas está siendo sistemáticamente atacada por políticas educativas conservadoras y neoliberales, cuya última batalla intenta justificar ideológicamente el proceso de privatización, segregación, reconfesionalidad y desmantelamiento de la educación pública con la enésima reforma educativa (LOMCE. Este artículo expone los principales aspectos de esta ley que desarrollan este enfoque ideológico y lo que implica su plasmación en la práctica educativa en nuestro sistema educativo.

  14. A gaseous scintillation counter filled with He3 for neutron spectrometry

    International Nuclear Information System (INIS)

    Baldin, S.A.; Matveev, V.V.

    1962-01-01

    The paper describes a gas plant and gaseous scintillation counter, and gives the results of experiments on the recording and spectrometry of neutron beams using a gaseous scintillation counter filled with a mixture of 10% xenene and 90% helium-3 at an overall pressure of 20 ata. Data are given on the design of the gas plant, which makes it possible to operate the counter continuously over long periods of time, as well as providing the required gas mixtures at overall pressures of up to 60 atm and ensuring constant freedom of the gas from contamination. In addition, the paper presents the results of research on the counter's energy resolution and linearity at different energy levels and indicates its efficiency in gamma fields of intensity up to 3 r/h; the possibility of extending the working energy-range of gaseous scintillation counters filled with helium-3 is also considered. (author) [fr

  15. Study of the rearrangement of N-alkylanilines to P-aminoalkylbencene. III. N-n-propil-l-14C aniline

    International Nuclear Information System (INIS)

    Molera, J. M.; Gamboa, J. M.; Val del Cob, M.; Ortin, N.

    1964-01-01

    The rearrangement of N-n-propyl aniline to p-amino propylbenzene has been studied at 250 degree centigrade using several catalysts: CoCl 2 , ZnCl 2 and HBr. N-propyl-1-14 C -aniline has been synthesized from sodium propionate-1-14 C through conversion to n-propyl-1-14 C -iodide and further reaction with aniline. After the rearrangement and among the reaction products both p-aminopropylbenzene and p-aminoisopropylbencene were found. To determine the 14 C position in both the starting aniline and reaction products two degradation schemes are followed. In the light of experimental evidence a mechanism is set forth based on the assumption of an organic cation as intermediate. (Author) 13 refs

  16. A miniature spark counter for public communication and education

    International Nuclear Information System (INIS)

    Mao, C.H.; Weng, P.S.

    1987-01-01

    The fabrication of a miniature spark counter for public communication and education using naturally occurring radon as a radioactive source without involving any man-made radioactivity is described. The battery-powered miniature spark counter weighs 2.07 kg with a volume of 4.844 x 10/sup -4/ m/sup 3/. The circuitry consists of seven major components: timer, high-voltage power supply, attenuator, noninverting amplifier, low-pass filter, one-shot generator, and counter. Cellulose nitrate films irradiated with alpha particles from radon emanating from soil were etched and counted. The visible sparks during counting are rather heuristic, which can be used to demonstrate naturally occurring radioactivity in classrooms or showplaces

  17. Hardware support for collecting performance counters directly to memory

    Science.gov (United States)

    Gara, Alan; Salapura, Valentina; Wisniewski, Robert W.

    2012-09-25

    Hardware support for collecting performance counters directly to memory, in one aspect, may include a plurality of performance counters operable to collect one or more counts of one or more selected activities. A first storage element may be operable to store an address of a memory location. A second storage element may be operable to store a value indicating whether the hardware should begin copying. A state machine may be operable to detect the value in the second storage element and trigger hardware copying of data in selected one or more of the plurality of performance counters to the memory location whose address is stored in the first storage element.

  18. Reaction πN → ππN near threshold

    Energy Technology Data Exchange (ETDEWEB)

    Frlez, Emil [Univ. of Virginia, Charlottesville, VA (United States)

    1993-11-01

    The LAMPF E1179 experiment used the π0 spectrometer and an array of charged particle range counters to detect and record π+π0, π0p, and π+π0p coincidences following the reaction π+p → π0π+p near threshold. The total cross sections for single pion production were measured at the incident pion kinetic energies 190, 200, 220, 240, and 260 MeV. Absolute normalizations were fixed by measuring π+p elastic scattering at 260 MeV. A detailed analysis of the π0 detection efficiency was performed using cosmic ray calibrations and pion single charge exchange measurements with a 30 MeV π- beam. All published data on πN → ππN, including our results, are simultaneously fitted to yield a common chiral symmetry breaking parameter ξ =-0.25±0.10. The threshold matrix element |α00π+p)| determined by linear extrapolation yields the value of the s-wave isospin-2 ππ scattering length α$2\\atop{0}$(ππ) = -0.041±0.003 m$-1\\atop{π}$-1, within the framework of soft-pion theory.

  19. A test of planar spark counters at the PEP storage ring

    International Nuclear Information System (INIS)

    Atwood, W.B.; Bowden, G.B.; Bonneaud, G.R.; Klem, D.E.; Ogawa, A.; Pestov, Yu.N.; Pitthan, R.; Sugahara, R.

    1983-01-01

    A test of planar spar counters (PSCs) at the PEP electron-positron storage ring showed the following. PSCs can be used under harsh experimental conditions without long term degradation of resolution. On-line time-of-flight resolutions were below 200 ps, coordinate resolutions better than 4 mm, both limited to these values by the resistivity of the semiconducting glass and the electronics used. The best single counter time resolution under realistic conditions at the storage ring was 76 ps. Pulse height was a good indicator of the number of particles striking a counter. Subsequent measurements using cosmis rays gave a single counter time resolution of 50 ps. (orig.)

  20. W and WSix Ohmic contacts on p- and n-type GaN

    International Nuclear Information System (INIS)

    Cao, X.A.; Ren, F.; Pearton, S.J.; Zeitouny, A.; Eizenberg, M.; Zolper, J.C.; Abernathy, C.R.; Han, J.; Shul, R.J.; Lothian, J.R.

    1999-01-01

    W and WSi Ohmic contacts on both p- and n-type GaN have been annealed at temperatures from 300 to 1000 degree C. There is minimal reaction (≤100 Angstrom broadening of the metal/GaN interface) even at 1000 degree C. Specific contact resistances in the 10 -5 Ω cm 2 range are obtained for WSi x on Si-implanted GaN with a peak doping concentration of ∼5x10 20 cm -3 , after annealing at 950 degree C. On p-GaN, leaky Schottky diode behavior is observed for W, WSi x and Ni/Au contacts at room temperature, but true Ohmic characteristics are obtained at 250 - 300 degree C, where the specific contact resistances are, typically, in the 10 -2 Ω cm 2 range. The best contacts for W and WSi x are obtained after 700 degree C annealing for periods of 30 - 120 s. The formation of β-W 2 N interfacial phases appear to be important in determining the contact quality. copyright 1999 American Vacuum Society

  1. A proportional counter for efficient backscatter Moessbauer effect spectroscopy

    International Nuclear Information System (INIS)

    Pawlowski, Z.; Marzec, J.; Cudny, W.; Holnicka, J.; Walentek, J.

    1979-01-01

    The authors present a novel gas-tight proportional counter with flat beryllium windows for backscatter Moessbauer spectroscopy. The krypton-filled counter has a geometry that approaches 2π and a resolution of 12% fwhm for the 14.4 keV line of 57 Fe, and is easy to manufacture. (Auth.)

  2. Ensaio de adubação N-P-K em amendoim N-P-K fertilizer test with peanuts

    Directory of Open Access Journals (Sweden)

    H. Gargantini

    1958-01-01

    Full Text Available O presente ensaio, conduzido em vasos de Mitscherlich contendo terra-roxa-misturada, foi instalado com a finalidade de se determinar o efeito dos elementos fertilizantes nitrogênio, fósforo e potássio, na produção do amendoim. Empregou-se para êste estudo o delineamento fatorial 3x4x3, contendo cada tratamento três repetições. Foram colhidos separadamente a parte aérea e os frutos e sôbre êstes dois fatôres foi estudada a ação daqueles elementos fertilizantes. Os dados coletados mostram haver semelhança entre os resultados com a produção da parte aérea e a dos frutos. O elemento responsável pela maior produção foi o fósforo, vindo a seguir o nitrogênio; o potássio não teve influência no aumento de produção. Pelos dados obtidos neste experimento deduz-se que a fórmula de adubação que melhores resultados apresentou foi a N1P3, ou sejam, 30 e 240 quilos de N e P2O5 por hectare, respectivamente.The present test was carried out with peanut plants grown in Mitscherlich pots filled with the "terra-roxa-misturada" type of soil. Its objective was to determine the influence of the three major elements, viz. nitrogen, phosphorus, and potassium on the yield. A 3 x 4 x 3 factorial design was employed, each treatment being replicated 3 times. Both the aerial parts of the plants and the fruit were harvested separately and used for statistical analysis. Fruit yield and weight of aerial parts showed similar responses to the treatments. Phosphorus increased the yield the most, followed by nitrogen; potash had no influence on yield. According to the results obtained the best formula was N1P3, corresponding to 30 and 240 kg of N and P2O5 per hectare, respectively.

  3. Intermediate nuclear structure for 2ν2β decay of 48Ca studied by (p, n) and (n, p) reactions at 300 MeV

    International Nuclear Information System (INIS)

    Sakai, H.; Yako, K.

    2009-01-01

    The two neutrino double beta (2ν2β) decay proceeds through a sequence of Gamow-Teller (GT) transitions, namely from the parent nucleus to the intermediate nucleus and then from the intermediate nucleus to the final daughter nucleus. The nuclear matrix element M 2ν for the 2ν2β - decay thus consists of the 2β - decay matrix elements for the parent nucleus decay and the 2β - decay matrix elements for the intermediate nucleus decay. These 2β - decay matrix elements can be studied experimentally through the (p, n) reaction for the parent nucleus decay and the (n, p) reaction for the intermediate nucleus decay. The 2ν2β-decay nucleus, 4 8C a is studied. The charge exchange (p, n) and (n, p) measurements at 300 MeV were performed using the neutron time-of-flight facility and the (n,p) facility, respectively, at RCNP. The (p, n) measurement on 4 8C a and the (n,p) measurement on 4 8T i provided us, for the first time, reliable B(GT - ) and B(GT + ) strength distributions up to high excitation energy of 30 MeV of the intermediate nucleus 4 8S c. The multipole decomposition analysis was applied to the angular distributions of the cross section spectra to extract the ΔL = 0 components, which are used to deduce B(GT ± ). Figure shows the double differential cross Nb sections for 4 8C a(p, n)4 8S c (left panel) and 4 8T i(n,p)4 8S c (right panel) reactions. The histograms show the results of the multi-pole decomposition analyses. It is very surprising to find sizable amount of ΔL = 0 yield, i.e. B(GT + ) strength in the highly excited energy region (> 10 MeV). The obtained B(GT ± ) distribution in 4 8S c as well as corresponding nuclear matrix elements M 2ν are compared with theoretical shell model calculation. In this talk, new results will be presented and their implication to the nuclear matrix elements for the 2ν2β-decay will be discussed (author)

  4. Flaxseed Response To N, P, and K Fertilization in South Central Chile Respuesta a la Fertilización N, P y K en Lino Oleaginoso en la Zona Centro Sur de Chile

    Directory of Open Access Journals (Sweden)

    Marisol Berti

    2009-06-01

    Full Text Available Flaxseed (Linum usitatissimum L. is a minor crop in Chile. There is interest to increase the number of crops on the current rotation in South Central Chile and also to increase oilseed feedstocks for salmon feed. There is little information published about seed yield and oil content response to N, P, and K fertilizers on flaxseed in Chile. The objective of this study was to determine the effect of N, P, and K fertilization on flaxseed yield, oil content, and composition. The study was conducted at two locations during two growing seasons (environments, in Chillán 2004-2005, 2005-2006, and in Osorno 2004-2005, 2006-2007. Treatments were four levels of N (0, 100, 200, and 300 kg N ha-1, three levels of P (0,100, and 200 kg P2O5 ha-1, and two levels of K (0 and 150 kgK2O ha-1. The design was a randomized complete block with a factorial arrangement of three factors (N, P, and K and four replicates. According to the results, flaxseed yield improved as N rates increased. Physical optimum rate (rate at which maximum seed yield is obtained was different depending on the location and year. Nitrogen rate increased oil content and yield up to 200 kg N ha-1. Oil composition was not affected by N, P, and K rates, or their interactions. The P and K nutrients did not have an effect on seed yield, oil content, oil yield, and oil composition.El lino oleaginoso (Linum usitatissimum L. es un cultivo menor en Chile. En la zona centro sur existe interés por ampliar las alternativas para la rotación de cultivos, así como la necesidad de satisfacer la demanda por semillas oleaginosas para la alimentación de salmones. En Chile no hay información relacionada con la respuesta del lino frente a la fertilización. El objetivo del estudio fue evaluar el efecto de N, P y K sobre el rendimiento de semillas y contenido de aceite en lino cultivado en dos localidades: Chillán (temporadas 2004-2005 y 2005-2006 y Osorno (temporadas 2004-2005 y 2006-2007 (ambientes. Los

  5. Long-term interactive effects of N addition with P and K availability on N status of Sphagnum.

    Science.gov (United States)

    Chiwa, Masaaki; Sheppard, Lucy J; Leith, Ian D; Leeson, Sarah R; Tang, Y Sim; Neil Cape, J

    2018-06-01

    Little information exists concerning the long-term interactive effect of nitrogen (N) addition with phosphorus (P) and potassium (K) on Sphagnum N status. This study was conducted as part of a long-term N manipulation on Whim bog in south Scotland to evaluate the long-term alleviation effects of phosphorus (P) and potassium (K) on N saturation of Sphagnum (S. capillifolium). On this ombrotrophic peatland, where ambient deposition was 8 kg N ha -1 yr -1 , 56 kg N ha -1 yr -1 of either ammonium (NH 4 + , N red ) or nitrate (NO 3 - , N ox ) with and without P and K, were added over 11 years. Nutrient concentrations of Sphagnum stem and capitulum, and pore water quality of the Sphagnum layer were assessed. The N-saturated Sphagnum caused by long-term (11 years) and high doses (56 kg N ha -1 yr -1 ) of reduced N was not completely ameliorated by P and K addition; N concentrations in Sphagnum capitula for N red 56 PK were comparable with those for N red 56, although N concentrations in Sphagnum stems for N red 56 PK were lower than those for N red 56. While dissolved inorganic nitrogen (DIN) concentrations in pore water for N red 56 PK were not different from N red 56, they were lower for N ox 56 PK than for N ox 56 whose stage of N saturation had not advanced compared to N red 56. These results indicate that increasing P and K availability has only a limited amelioration effect on the N assimilation of Sphagnum at an advanced stage of N saturation. This study concluded that over the long-term P and K additions will not offset the N saturation of Sphagnum. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Body counter

    International Nuclear Information System (INIS)

    Koeppe, P.

    1975-01-01

    The paper gives a survey on some applications of the whole body counter in clinical practice and a critical study of its application as a routine testing method. Remarks on the necessary precautions are followed by a more detailed discussion of the determination of the natural potassium content, the iron metabolism, the vitamin B12 test, investigations of the metabolism of the bone using 47 Ca and 85 Sr, investigations with iodine and iodine-labelled substances, clearance investigations (in particular the 51 Cr EDTA clearance test), as well as the possibilities of neutron activation in vivo. (ORU/AK) [de

  7. Synthesis of p-type nickel oxide nanosheets on n-type titanium dioxide nanorod arrays for p-n heterojunction-based UV photosensor

    Science.gov (United States)

    Yusoff, M. M.; Mamat, M. H.; Malek, M. F.; Abdullah, M. A. R.; Ismail, A. S.; Saidi, S. A.; Mohamed, R.; Suriani, A. B.; Khusaimi, Z.; Rusop, M.

    2018-05-01

    Titanium dioxide (TiO2) nanorod arrays (TNAs) were synthesized and deposited on fluorine tin oxide (FTO)-coated glass substrate using a novel and facile immersion method in a glass container. The synthesis and deposition of p-type nickel oxide (NiO) nanosheets (NS) on the n-type TNAs was investigated in the p-n heterojunction photodiode (PD) for the application of ultraviolet (UV) photosensor. The fabricated TNAs/NiO NS based UV photosensor exhibited a highly increased photocurrent of 4.3 µA under UV radiation (365 nm, 750 µW/cm2) at 1.0 V reverse bias. In this study, the fabricated TNAs/NiO NS p-n heterojunction based photodiode showed potential applications for UV photosensor based on the stable photo-generated current attained under UV radiation.

  8. Discharge quenching circuit for counters

    International Nuclear Information System (INIS)

    Karasik, A.S.

    1982-01-01

    A circuit for quenching discharges in gas-discharge detectors with working voltage of 3-5 kV based on transistors operating in the avalanche mode is described. The quenching circuit consists of a coordinating emitter follower, amplifier-shaper for avalanche key cascade control which changes potential on the counter electrodes and a shaper of discharge quenching duration. The emitter follower is assembled according to a widely used flowsheet with two transistors. The circuit permits to obtain a rectangular quenching pulse with front of 100 ns and an amplitude of up to 3.2 kV at duration of 500 μm-8 ms. Application of the quenching circuit described permits to obtain countering characteristics with the slope less than or equal to 0.02%/V and plateau extent greater than or equal to 300 V [ru

  9. The study of the influence of helium on the counter's measurement properties

    International Nuclear Information System (INIS)

    Guan Rui; Weng Kuiping; Ren Xingbi

    2009-04-01

    In measurement of tritium by the proportional counter, methane is usually used as counter gas. Gas samples have been made with helium and methane in the proportion of concentration and measured to study the influence of helium on the counter's measurement properties. Then gas sample with tritium and helium has been measured, and the result is according with anticipation. The experiment has showed that the plateau curve of counter could be changed by helium, but the influence could be ignored when helium concentration less 10%. (authors)

  10. Characterization of vertical GaN p-n diodes and junction field-effect transistors on bulk GaN down to cryogenic temperatures

    Science.gov (United States)

    Kizilyalli, I. C.; Aktas, O.

    2015-12-01

    There is great interest in wide-bandgap semiconductor devices and most recently in vertical GaN structures for power electronic applications such as power supplies, solar inverters and motor drives. In this paper the temperature-dependent electrical behavior of vertical GaN p-n diodes and vertical junction field-effect transistors fabricated on bulk GaN substrates of low defect density (104 to 106 cm-2) is described. Homoepitaxial MOCVD growth of GaN on its native substrate and the ability to control the doping in the drift layers in GaN have allowed the realization of vertical device architectures with drift layer thicknesses of 6 to 40 μm and net carrier electron concentrations as low as 1 × 1015 cm-3. This parameter range is suitable for applications requiring breakdown voltages of 1.2 kV to 5 kV. Mg, which is used as a p-type dopant in GaN, is a relatively deep acceptor (E A ≈ 0.18 eV) and susceptible to freeze-out at temperatures below 200 K. The loss of holes in p-GaN has a deleterious effect on p-n junction behavior, p-GaN contacts and channel control in junction field-effect transistors at temperatures below 200 K. Impact ionization-based avalanche breakdown (BV > 1200 V) in GaN p-n junctions is characterized between 77 K and 423 K for the first time. At higher temperatures the p-n junction breakdown voltage improves due to increased phonon scattering. A positive temperature coefficient in the breakdown voltage is demonstrated down to 77 K; however, the device breakdown characteristics are not as abrupt at temperatures below 200 K. On the other hand, contact resistance to p-GaN is reduced dramatically above room temperature, improving the overall device performance in GaN p-n diodes in all cases except where the n-type drift region resistance dominates the total forward resistance. In this case, the electron mobility can be deconvolved and is found to decrease with T -3/2, consistent with a phonon scattering model. Also, normally-on vertical junction

  11. Counter-transference reactions contributing to completed suicide.

    Science.gov (United States)

    Modestin, J

    1987-12-01

    Counter-transference reactions are frequently elicited while treating suicidal patients and they may contribute to the patient's committing suicide. Therapeutic constellations including the failure of the therapist to (1) cope with the patient's aggressiveness, (2) tolerate the patient's dependency, (3) handle the erotic transference adequately and (4) preserve loyalty towards the patient; they have all been identified as being responsible for a therapeutic impasse with fatal consequences. Knowledge of the therapeutic constellations especially prone to facilitate negative counter-transference reactions may help the therapist to master them effectively.

  12. Solvability of a (p, n-p-type multi-point boundary-value problem for higher-order differential equations

    Directory of Open Access Journals (Sweden)

    Yuji Liu

    2003-12-01

    Full Text Available In this article, we study the differential equation $$ (-1^{n-p} x^{(n}(t=f(t,x(t,x'(t,dots,x^{(n-1}(t, $$ subject to the multi-point boundary conditions $$displaylines{ x^{(i}(0=0 quad hbox{for }i=0,1,dots,p-1,cr x^{(i}(1=0 quad hbox{for }i=p+1,dots,n-1,cr sum_{i=1}^malpha_ix^{(p}(xi_i=0, }$$ where $1le ple n-1$. We establish sufficient conditions for the existence of at least one solution at resonance and another at non-resonance. The emphasis in this paper is that $f$ depends on all higher-order derivatives. Examples are given to illustrate the main results of this article.

  13. Hydrogen diffusion at moderate temperatures in p-type Czochralski silicon

    International Nuclear Information System (INIS)

    Huang, Y.L.; Ma, Y.; Job, R.; Ulyashin, A.G.

    2004-01-01

    In plasma-hydrogenated p-type Czochralski silicon, rapid thermal donor (TD) formation is achieved, resulting from the catalytic support of hydrogen. The n-type counter doping by TD leads to a p-n junction formation. A simple method for the indirect determination of the diffusivity of hydrogen via applying the spreading resistance probe measurements is presented. Hydrogen diffusion in silicon during both plasma hydrogenation and post-hydrogenation annealing is investigated. The impact of the hydrogenation duration, annealing temperature, and resistivity of the silicon wafers on the hydrogen diffusion is discussed. Diffusivities of hydrogen are determined in the temperature range 270-450 deg. C. The activation energy for the hydrogen diffusion is deduced to be 1.23 eV. The diffusion of hydrogen is interpreted within the framework of a trap-limited diffusion mechanism. Oxygen and hydrogen are found to be the main traps

  14. Derechos de propiedad y costos de transacción en administración pública

    Directory of Open Access Journals (Sweden)

    Diana Vicher

    2010-01-01

    Full Text Available La presente colaboración reseña las principales transformaciones econó-micas mundiales verificadas desde que se estableció el orden económico de Bretton Woods, hasta finales de la década de 1970, para explicar cómo generó el cambio negativo en la opinión favorable que se tenía sobre el Estado y la administración pública, mismo que determinó modificaciones sustanciales en ambos. Las disposiciones para este cambio provendría esencialmente del ideario de la economía neoclásica, de la Escuela de Chicago y la de Virginia, donde se desarrollaron postulados que analizaron al Estado y su administración desde preceptos económicos de dicha índole. De la conjunción de ideas de ese pensamiento (junto con otras innovaciones generadas en la administración privada se conformó un modelo de reforma de la administración pública denominado “Nueva Gerencia Pública”, cuyos elementos son los clientes, los mercados, la competencia y los contratos. Pero, este modelo no es sino una privatización orientada hacia el interior de la administración pública (endoprivatización. Aunque son diversos los componentes de la nueva gerencia pública, en este caso abordaremos las ideas vinculadas con los postulados relativos a los “costos de transacción”, razonamientos que se han utilizado para recomendar el establecimiento de “mercados de derechos de propiedad” en la gestión de asuntos comunes. Estas nociones son algunas de las que se propusieron como vías pertinentes para fomentar la competencia en la administración pública.

  15. Ética pública y deber de abstención en la actuación administrativa

    Directory of Open Access Journals (Sweden)

    José Luis Martínez López-Muñiz

    2011-12-01

    Full Text Available La ética debe impulsar, sostener, inspirar y complementar al Derecho, aunque lo exigible al poder público, bajo el Estado social y democrático de Derecho, es su plena sumisión a este. El deber de abstención de los servidores públicos cuando se encuentran en las situaciones que la ley determine por comportar riesgo de parcialidad o de servicio a algún interés particular y no a los fines públicos es solo una medida precautoria, que busca la mejor garantía de la efectiva sumisión de toda actuación del poder público al Derecho, así como también favorecer la confianza del ciudadano en las autoridades y en los empleados públicos. Esto ha sido construido en el siglo XX, a partir de la figura de la recusación, de gran arraigo histórico en el ámbito judicial, la cual ha pasado a ser incluida en la configuración institucional. La comparación de su regulación en el ámbito administrativo en los derechos peruano y español favorece un análisis de las particularidades de su régimen jurídico.

  16. Interaction between counter-streaming ion-acoustic solitons and the Langmuir waves

    International Nuclear Information System (INIS)

    Basovich, A.Ya.; Gromov, E.M.; Talanov, V.I.

    1984-01-01

    The interaction between strong counter-streaming ion-acoustic solitons and the Langmuir waves is considered. At first the Langmuir waves spectrum transformation by counter-streaming ion-acoustic solutions of a preset amplitude e has been found. An increase in the frequency and number of the Langmuir waves due to the Doppler effect in the course of multiple reflection from the f front soliton slope has been determined and the wave number range in which the confinement of the Langmuir waves by counter-streaning solitons is possible has s been found. It is shown that the time of the Langmuir wave transformation into the short-wave region under the effect of the counter-streaming soliton may y be short as compared with the time of the Langmuir wave diffusion into the Landau damping region under the effect of random fields of ion-acoustic waves. In the adiabatic fpproximation changes in the counter-streaming ion acoustic parameters of solitons owing to the Langmuir waves have been

  17. Solidarity and Recognition: Geographies of Counter-globalism

    Directory of Open Access Journals (Sweden)

    James Goodman

    2006-02-01

    Full Text Available Globalism is a contested concept, but perhaps best understood as a spatial strategy, which disempowers those unable to transcend the fixity of place and social context. Under globalism fluidity becomes a key source of power, enabling the powerful to liquefy assets, to disembed, and thereby displace, political, social or ecological impacts. The infrastructures of globalism enable the disembodied extension of power across territory, to the extent that one model, universally applicable for all societies, is positioned as supreme. The only possible challenge to globalism perhaps, is through a similarly disembedded counter-movement, that mirrors the global reach and power of mainstream globalism. The praxis of counter-globalist movements suggests a different tendency, one that centres on the assertion of particularity against universality. Expressed in the legitimacy of ‘many worlds’ against ‘one world’ globalism, such resistance centres on exposing the material effects and foregrounding concrete and material experiences of globalism. Movements mobilise against the disembodied logic of globalism on the basis of co-presence and inter-subjectivity, and are embedded in relational concepts of selfhood. They are often intensely embodied and are radically emplaced through militant localism and trans-local dialogue. Counter-globalism thus does not seek to defeat geography; rather it embraces it, as the starting-point of mobilisation. The starting point of this article is thus to analyse globalism as a spatial strategy, a strategy of displacement grounded in material power. Globalism thus signifies the capacity to exploit and dominate at distance, from the sanctity of corporate boardrooms, military briefings and media cutting rooms. The claim is to universal market, military and normative power, but the impact is of extended and deepened division. Centres of power appear more as islands, or enclaves, defined against the backwash effects of counter

  18. Preparation, characterization and activity evaluation of p-n junction photocatalyst p-CaFe2O4/n-Ag3VO4 under visible light irradiation

    International Nuclear Information System (INIS)

    Chen Shifu; Zhao Wei; Liu Wei; Zhang Huaye; Yu Xiaoling; Chen Yinghao

    2009-01-01

    p-n junction photocatalyst p-CaFe 2 O 4 /n-Ag 3 VO 4 was prepared by ball milling Ag 3 VO 4 in H 2 O doped with p-type CaFe 2 O 4 . The structural and optical properties of the photocatalyst were characterized by X-ray powder diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and UV-vis diffuse reflection spectrum (DRS). The photocatalytic activity was evaluated by photocatalytic degradation of methylene blue (MB) under visible light irradiation. The results showed that the photocatalytic activity of the p-CaFe 2 O 4 /n-Ag 3 VO 4 was higher than that of Ag 3 VO 4 . When the amount of doped p-CaFe 2 O 4 was 2.0 wt.% and the p-CaFe 2 O 4 /n-Ag 3 VO 4 was ball milled for 12 h, the photocatalytic degradation efficiency was 85.4%. Effect of ball milling time on the photocatalytic activity of the photocatalyst was also investigated. The mechanisms of the increase in the photocatalytic activity were discussed by the p-n junction principle.

  19. Fabrication and characterization of GaN-based light-emitting diodes without pre-activation of p-type GaN.

    Science.gov (United States)

    Hu, Xiao-Long; Wang, Hong; Zhang, Xi-Chun

    2015-01-01

    We fabricated GaN-based light-emitting diodes (LEDs) without pre-activation of p-type GaN. During the fabrication process, a 100-nm-thick indium tin oxide film was served as the p-type contact layer and annealed at 500°C in N2 ambient for 20 min to increase its transparency as well as to activate the p-type GaN. The electrical measurements showed that the LEDs were featured by a lower forward voltage and higher wall-plug efficiency in comparison with LEDs using pre-activation of p-type GaN. We discussed the mechanism of activation of p-type GaN at 500°C in N2 ambient. Furthermore, x-ray photoemission spectroscopy examinations were carried out to study the improved electrical performances of the LEDs without pre-activation of p-type GaN.

  20. La gestión de las relaciones con los públicos

    OpenAIRE

    Carretón Ballester, María del Carmen (Coord.)

    2010-01-01

    Aborda investigaciones sobre las relaciones públicas en sectores especializados; estudios de casos; formación, estrategias y práctica profesional de las relaciones públicas y relaciones públicas, tecnologías de la información y gestión del conocimiento.

  1. Transparent platinum counter electrode for efficient semi-transparent dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Iefanova, Anastasiia; Nepal, Jeevan; Poudel, Prashant; Davoux, Daren; Gautam, Umesh [Electrical Engineering and Computer Science Department, South Dakota State University, Brookings, SD 57006 (United States); Mallam, Venkataiah [Chemistry and Biochemistry Department, South Dakota State University, Brookings, SD 57006 (United States); Qiao, Qiquan [Electrical Engineering and Computer Science Department, South Dakota State University, Brookings, SD 57006 (United States); Logue, Brian [Chemistry and Biochemistry Department, South Dakota State University, Brookings, SD 57006 (United States); Baroughi, Mahdi Farrokh, E-mail: m.farrokhbaroughi@sdstate.edu [Electrical Engineering and Computer Science Department, South Dakota State University, Brookings, SD 57006 (United States)

    2014-07-01

    A method for fabrication of highly transparent platinum counter electrodes (CEs) has been developed based on spray coating of Pt nanoparticles (NPs) on hot substrates. This method leads to 86% reduction in Pt consumption reducing the Pt cost per peak watt of counter electrode from $0.79/Wp down to $0.11/Wp compared to the conventional Pt counter electrodes made by sputter deposition. The simplicity and low cost of this method provide a basis for an up-scalable fabrication process. The Pt NP layer is over 88% transparent, leading to overall transparency of 80% when incorporated with indium tin oxide/glass substrates for functional counter electrodes. This counter electrode exhibits a large surface area and high catalytic activity, comparable to that of the conventional opaque CEs. Semi-transparent dye-sensitized solar cells fabricated based on this counter electrode showed 6.17% power conversion efficiency. - Highlights: • Counter electrode (CE) prepared by spraying nanoparticle (NP) Pt on hot substrate. • Low cost and scalable fabrication process of CE. • The spray deposited CE uses 10 times less Pt compared to the sputtering method. • The CE is 80% transparent and exhibits a large surface and high catalytic activity. • A semitransparent dye-sensitized solar cell with Pt NP CE was 6.17% efficient.

  2. Background compensated GM counter for the measurement of low level #betta#-activity

    International Nuclear Information System (INIS)

    Mori, C.; Kumanomido, H.; Watanabe, T.

    1983-01-01

    When low level activity of a #betta#-ray source or surface contamination is to be measured with a GM counter, it is desirable to obtain a net count without background count through a single measurement. An end-window GM counter for such a purpose was constructed. The counter has a diaphragm to divide it into two parts. The front part, the window side, can detect #betta#-rays and background radiations, while the rear part only detects background, since #betta#-rays coming through the front are absorbed by the diaphragm. In the counter type I, the sensitive volumes of the two parts are the same and the anode wire of the front is connected to that of the rear through an electric resistor which leads to yielding different pulse heights and rise times. The net count of #betta#-rays can be obtained through a single measurement by subtracting the count in the rear part from that in the front part. In the counter type II, the lengths of the anode wires of the two parts are different, which gives rise to different pulse heights. With a background compensated GM counter, it is possible to shorten the measuring time, keeping nearly the same accuracy compared with a conventional GM counter. (orig.)

  3. Comunicación pública, comunicación política y democracia: un cruce de caminos

    Directory of Open Access Journals (Sweden)

    Luis Horacio Botero Montoya

    2006-01-01

    Full Text Available Hablar de comunicación pública y comunicación política, y la posibilidad de que ambas construyan democracia, resulta un asunto bastante arriesgado, máxime cuando lo dominante en el paradigma actual de la comunicación, cualesquiera que sean sus vertientes, se asocia más con el mundo de la forma, de lo superficial y de lo aparente, que con la posibilidad de explorar espacios y desarrollar procesos que le apuesten a la construcción de democracia. Este trabajo surge como resultado inicial del proyecto de investigación en comunicación pública denominado “Comunicación pública: un espacio para la construcción de democracia”, que adelanta el grupo de investigación Corpus, y que auspicia la Vicerrectoría de Investigaciones de la Universidad de Medellín. Es una propuesta abierta, crítica y compleja, que invita a los investigadores en estos tópicos a construir propuestas de comunicación pública que articulen y permitan un cruce de caminos con lo público y lo político, y con la democracia.

  4. Configuración del paisaje, espacio público y arte público en el Perú

    Directory of Open Access Journals (Sweden)

    Verónica Crousse Rastelli

    2012-02-01

    Full Text Available En este artículo se discuten algunos aspectos que fueron materia de estudio en mi tesis doctoral “Reencontrando la espacialidad para el arte público en el Perú”, desarrollada en el doctorado “Espacio público y Regeneración Urbana; arte, teoría y conservación del Patrimonio” de la Universidad de Barcelona, bajo la dirección del Dr. Antoni Remesar. La tesis indaga sobre la construcción del paisaje en el Perú, y en el arte público como elemento configurador de estos paisajes. Ante el análisis de un panorama contemporáneo en el que prima la distorsión tanto de la función del arte público como de su implementación y gestión, se intenta con esta tesis poner en valor la espacialidad en las prácticas de construcción de paisaje de los antiguos peruanos, para identificar sus principios y valores y así poderlos reinterpretar conceptualmente dentro de las prácticas contemporáneas de arte público en el Perú. Se estudia detalladamente aquellos aislados ejemplos de arte público peruano (en gran medida ya desaparecidos o en vías de hacerlo y de artistas contemporáneos que han basado su búsqueda en la reinterpretación de esa espacialidad. Por otro lado, la tesis aporta la mirada que reconoce la supervivencia de dichos valores no en el mayoritario arte público contemporáneo, sino en los desarrollos espontáneos que se materializan en el paisaje rural por acción de labores productivas herederas a su vez de prácticas ancestrales. Se concluye proponiendo unos principios orientadores de buenas prácticas para el arte público contemporáneo peruano, que incorporan tanto la especificidad territorial de nuestros contextos como los principios y valores espaciales reconocidos en nuestro bagaje paisajístico y cultural, que permitan plantear desde nuestra identidad y de manera responsable una configuración alternativa del paisaje urbano y del arte público peruano. En este artículo nos centraremos principalmente en las maneras

  5. Monte Carlo simulation of neutron counters for safeguards applications

    International Nuclear Information System (INIS)

    Looman, Marc; Peerani, Paolo; Tagziria, Hamid

    2009-01-01

    MCNP-PTA is a new Monte Carlo code for the simulation of neutron counters for nuclear safeguards applications developed at the Joint Research Centre (JRC) in Ispra (Italy). After some preliminary considerations outlining the general aspects involved in the computational modelling of neutron counters, this paper describes the specific details and approximations which make up the basis of the model implemented in the code. One of the major improvements allowed by the use of Monte Carlo simulation is a considerable reduction in both the experimental work and in the reference materials required for the calibration of the instruments. This new approach to the calibration of counters using Monte Carlo simulation techniques is also discussed.

  6. Measurements of Radon Concentration in Yemen Using Spark Counter

    International Nuclear Information System (INIS)

    Arafa, W.; Abou-Leila, M.; Hafiz, M.E.; Al-Glal, N.

    2011-01-01

    Spark counter has been designed and realized and the optimum applied voltage was found to be 600 V. Excellent consistent agreements was observed between counted number of tracks by spark counter and reading by optical microscope. Radon concentration in some houses in Sana'a and Hodeidah cities in Yemen had been performed using LR-115 SSNTD and spark counter system. The average radon concentration in both cities was far lower the alert value. The results showed that radon concentration in the metropolitan area Sana'a was higher than that in Hodeidah city. Also, it was observed that old residential houses had higher levels of radon concentrations have compared to newly built houses in the metropolitan area Sana'a

  7. High-level neutron coincidence counter (HLNCC): users' manual

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1979-06-01

    This manual describes the portable High-Level Neutron Coincidence Counter (HLNCC) developed at the Los Alamos Scientific Laboratory (LASL) for the assay of plutonium, particularly by inspectors of the International Atomic Energy Agency (IAEA). The counter is designed for the measurement of the effective 240 Pu mass in plutonium samples which may have a high plutonium content. The following topics are discussed: principle of operation, description of the system, operating procedures, and applications

  8. A comprehensive test specification for pulse fission counters

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, D L [Control and Instrumentation Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1962-02-15

    The following test specification is based on the memorandum AERE - M 728 which it now replaces It contains a standard acceptance test procedure for the many U.K.A.E.A, designed pulse fission counters now commercially available. This test specification may be used for any pulse fission counter provided a specification sheet as shown in Appendix 3 is supplied to the contractor quoting this report and including specified values for the measured quantities. (author)

  9. La Neurociencia para la innovación de contenidos en la televisión pública europea

    Directory of Open Access Journals (Sweden)

    2017-07-01

    Full Text Available El nuevo panorama mediático, caracterizado por la fragmentación y desafección de las audiencias hacia la televisión tradicional, urge la incorporación de innovadoras estrategias que atiendan a las demandas de sus públicos y conecten con ellos. El presente artículo analiza la capacidad de la Neurociencia para optimizar la producción de contenidos adaptados a las preferencias de los espectadores y comprueba la introducción de esta metodología en las radiotelevisiones públicas europeas. Para ello se realizó una revisión de los informes de gestión, memorias de cuentas y webs de las radiotelevisiones públicas estatales y regionales de la Unión Europea (N=100 así como de la evolución de sus audiencias de 2010-15. Complementariamente, a partir de un análisis exploratorio y de entrevistas en profundidad con cuestionario abierto y cerrado, se recogió la opinión de expertos neurocientíficos, consultores de Neuromarketing, académicos y profesionales de la televisión pública europea (N=22 sobre la utilidad e introducción de esta ciencia para el estudio de las audiencias y su aplicación en la programación, y el rol de la Neuroeducación en el diseño de programas educativos. Los resultados determinan que cerca de una docena de RTV públicas ya aplican el Neuromarketing audiovisual como herramienta innovadora para probar y diseñar productos de entretenimiento, bloques comerciales y estrategias de mejora de la competitividad frente a su implementación en la programación educativa, encomienda principal del servicio público.

  10. RHIZOME YIELD OF TEMULAWAK (Curcuma xanthorrhiza Roxb. AT N, P, K VARIOUS LEVEL AND N, K COMBINATION

    Directory of Open Access Journals (Sweden)

    Ellis Nihayati

    2014-02-01

    Full Text Available The role of N, P and K on temulawak have not been clear enough to explain the need in temulawak rhizome in order to get high yield. The experiment was conducted in a screen house in Malang East Java with an altitude of 500 m asl. from Desember 2010 - August 2011. There were 4 experiments in series, consisting of N, P, K various level and N,K alone and combination on the growth and quantity of rhizome arranged in randomized block design comprising 7 levels of fertilizer per plant with 3 replications. The treatments of urea (N, SP36 (P consisted of 0, 1,25, 2,5, 3,75, 5, 6,25 and 7.5 g. The KCl (K comprised 0, 1,5, 3, 4,5, 6, 7,5 and 9 g. The N, K alone and combination treatments consisted of (No fertilizer, N, K, NK g /plant. The results of this research were N, P, K optimum dose of each N 6.25 g N / plant P2O5/tan P 6.25 g, K 7.5 g K2O / plant increased temulawak rhizome dry weight. Combination 4.5 g N + 2.8 g K / plant could increase temulawak rhizome dry weight by 33% compared to the addition of N and 220% when compared to the addition of a single K harvesting age 6 months.

  11. Development of aerogel Cherenkov counters at Novosibirsk

    International Nuclear Information System (INIS)

    Barnyakov, A.Yu.; Barnyakov, M.Yu.; Baehr, J.; Bellunato, T.; Beloborodov, K.I.; Bobrovnikov, V.S.; Buzykaev, A.R.; Calvi, M.; Danilyuk, A.F.; Djordjadze, V.; Golubev, V.B.; Kononov, S.A.; Kravchenko, E.A.; Lipka, D.; Matteuzzi, C.; Musy, M.; Onuchin, A.P.; Perego, D.; Rodiakin, V.A.; Savinov, G.A.; Serednyakov, S.I.; Shamov, A.G.; Stephan, F.; Tayursky, V.A.; Vorobiov, A.I.

    2006-01-01

    The work on aerogel Cherenkov counters was started in Novosibirsk in 1986. Production of aerogels with refractive indices of 1.006-1.13 and thicknesses of blocks up to 50mm was developed. The light absorption length at 400nm is 5-7m, the scattering length is 4-5cm. By these parameters, the Novosibirsk aerogel is one of the best in the world. The ASHIPH Cherenkov counters with light collection on wavelength shifters have been developed. The ASHIPH system of the KEDR detector contains 1000l of aerogel. The π/K separation is 4.5σ. A project of ASHIPH counters for the SND detector has been developed. Aerogel RICH for LHCb gives a possibility to identify hadrons in the momentum range of 2-10GeV/c. The Novosibirsk group is developing an aerogel RICH for the endcap for the SuperBaBar project. Calculations performed by a group of physicists from Novosibirsk and DESY-Zeuthen have shown that aerogel radiators enable to achieve time resolution up to 20fs

  12. PROTON HEATING IN SOLAR WIND COMPRESSIBLE TURBULENCE WITH COLLISIONS BETWEEN COUNTER-PROPAGATING WAVES

    Energy Technology Data Exchange (ETDEWEB)

    He, Jiansen; Tu, Chuanyi; Wang, Linghua; Pei, Zhongtian [School of Earth and Space Sciences, Peking University, Beijing, 100871 (China); Marsch, Eckart [Institute for Experimental and Applied Physics, Christian-Albrechts-Universität zu Kiel, D-24118 Kiel (Germany); Chen, Christopher H. K. [Department of Physics, Imperial College London, London SW7 2AZ (United Kingdom); Zhang, Lei [Sate Key Laboratory of Space Weather, Chinese Academy of Sciences, Beijing 100190 (China); Salem, Chadi S.; Bale, Stuart D., E-mail: jshept@gmail.com [Space Sciences Laboratory, University of California, Berkeley, CA 94720 (United States)

    2015-11-10

    Magnetohydronamic turbulence is believed to play a crucial role in heating laboratory, space, and astrophysical plasmas. However, the precise connection between the turbulent fluctuations and the particle kinetics has not yet been established. Here we present clear evidence of plasma turbulence heating based on diagnosed wave features and proton velocity distributions from solar wind measurements by the Wind spacecraft. For the first time, we can report the simultaneous observation of counter-propagating magnetohydrodynamic waves in the solar wind turbulence. As opposed to the traditional paradigm with counter-propagating Alfvén waves (AWs), anti-sunward AWs are encountered by sunward slow magnetosonic waves (SMWs) in this new type of solar wind compressible turbulence. The counter-propagating AWs and SWs correspond, respectively, to the dominant and sub-dominant populations of the imbalanced Elsässer variables. Nonlinear interactions between the AWs and SMWs are inferred from the non-orthogonality between the possible oscillation direction of one wave and the possible propagation direction of the other. The associated protons are revealed to exhibit bi-directional asymmetric beams in their velocity distributions: sunward beams appear in short, narrow patterns and anti-sunward in broad extended tails. It is suggested that multiple types of wave–particle interactions, i.e., cyclotron and Landau resonances with AWs and SMWs at kinetic scales, are taking place to jointly heat the protons perpendicular and in parallel.

  13. Counter diffusion of zinc and iron in alluvial soil

    International Nuclear Information System (INIS)

    Rattan, R.K.; Deb, D.L.

    1980-01-01

    Half cell technique showed that an increase in moisture tension and CaCO 3 content caused reduction in the counter diffusion coefficients of zinc and iron in an alluvial soil. Increases in bulk density, ambient temperature and concentration of synthetic chelating agents e.g. EDTA and DTPA increased the counter diffusion coefficients of both zinc and iron. (author)

  14. Financiarización y gasto público en México, 2000-2011

    Directory of Open Access Journals (Sweden)

    José Enrique Mendoza Méndez

    2012-09-01

    Full Text Available La transformación de la participación del Estado en la economía validó nuevas formas de realización de la ganancia, especialmente en el sector financiero. Aquí se analizan las repercusiones de la financiarización en el gasto público en México, poniendo énfasis en el costo financiero de la deuda pública. La pregunta que guía esta colaboración es: ¿de qué manera la estructura y dinámica del gasto público en México ha respondido a las necesidades de valorización del capital financiero? La primera parte aborda el debate de la financiarización e impacto sobre el gasto público. En la segunda, se evalúa el ajuste fiscal y la contracción del gasto público, en especial pone énfasis en la dinámica y estructura del gasto público, y el balance financiero; además se indaga en la relación entre la deuda pública, su costo financiero e importancia en la estructura de gasto público. Por último, se destaca la relación en la volatilidad del capital internacional, las estrategias de esterilización monetaria y el costo de la deuda pública

  15. Activated graphene nanoplatelets as a counter electrode for dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Jiawei [Center for Advanced Photovoltaics, Department of Electrical Engineering, South Dakota State University, Brookings, South Dakota 57007 (United States); Department of Mechanical Engineering, North Dakota State University, Fargo, North Dakota 58102 (United States); Zhou, Zhengping; Qiao, Qiquan, E-mail: qiquan.qiao@sdstate.edu [Center for Advanced Photovoltaics, Department of Electrical Engineering, South Dakota State University, Brookings, South Dakota 57007 (United States); Sumathy, K. [Department of Mechanical Engineering, North Dakota State University, Fargo, North Dakota 58102 (United States); Yang, Huojun [Department of Construction Management and Engineering, North Dakota State University, Fargo, North Dakota 58102 (United States)

    2016-04-07

    Activated graphene nanoplatelets (aGNPs) prepared by a hydrothermal method using KOH as activating agent were used as counter electrode for high efficiency dye-sensitized solar cells (DSSCs). After the KOH activation, the scanning electron microscopy image shows that aGNPs demonstrate a more curled, rough, and porous morphology which could contain both micro- and mesopores. The KOH activation changed the stacked layers of GNPs to a more crumpled and curved morphology. The microstructure of large pores significantly increased the electrode surface area and roughness, leading to the high electrocatalytic activity for triiodide reduction at the counter electrode. The DSSCs fabricated using aGNP as counter electrodes were tested under standard AM 1.5 illumination with an intensity of 91.5 mW/cm{sup 2}. The device achieved an overall power conversion efficiency of 7.7%, which is comparable to the conventional platinum counter electrode (8%). Therefore, the low cost and high performance aGNP based counter electrode is a promising alternative to conventional Pt counter electrode in DSSCs.

  16. Lokal løn på kommunale arbejdspladser

    DEFF Research Database (Denmark)

    Holt, Helle

    medarbejdere – om deres erfaringer og refleksioner over forhandlingerne om lokal løn. De lokale forhandlinger sker bl.a. på baggrund af forhåndsaftaler, der som udgangspunkt er kønsneutrale, men alligevel opstår der lokale forskelle mellem mænds og kvinders løn. Ifølge de interviewede skyldes det, at et antal...... kvalifikationer anses som naturlige for kvinder og derfor ikke udløser tillæg, mens de samme kvalifikationer anses som faglige hos mænd og derfor udløser et tillæg. Rapporten viser også, at løn i høj grad betragtes som en privatsag på de kommunale arbejdspladser, og at forskelle i mænds og kvinders løn tilskrives...

  17. Countering 21st Century Threats

    DEFF Research Database (Denmark)

    Scharling Pedersen, Peter; Pillai, Chad M.; Hun, Lee Jae

    2015-01-01

    ), Counter-Terrorism (CT), and Security and Stability Operations (SSO). • Establishing a construct that allows a strategic Whole-of-Government capacity for operations coordinated by joint interagency task forces. • Continue to developing the Global SOF network. • Increased intelligence sharing in areas...

  18. Ionization Spectroscopic Measurement of nP Rydberg Levels of 87Rb Cold Atoms

    Science.gov (United States)

    Li, Yufan; Zaheeruddin, Syed; Zhao, Dongmei; Ma, Xinwen; Yang, Jie

    2018-05-01

    We created an ultracold plasma via the spontaneous ionization of cold dense Rydberg atoms of 87Rb in a magneto-optical trap (MOT), and measured the nS1/2 (n = 50-80), nP1/2 (n = 16-23), nP3/2 (n = 16-98), and nD5/2 (n = 49-96) Rydberg levels by detecting the electrons in the ultracold plasma. By fitting the energy levels of Rydberg states, the first ionization potential of 33690.950(11) cm-1 and the quantum defects of S, P, and D orbitals were obtained. The absolute transition energies of nS1/2 (n = 66-80), nP1/2 (n = 16-23), nP3/2 (n = 16-98), and nD5/2 (n = 58-96) states of 87Rb, as well as the quantum defects for p1/2 and p3/2 series, are given for the first time.

  19. Información pública y pacificación: dilemas y posibilidades

    Directory of Open Access Journals (Sweden)

    Carlos Alfonso Velásquez

    2001-01-01

    Full Text Available La calidad de la información pública sobre el proceso de paz y el conflicto que proveen los medios de comunicación, especialmente la televisión, juega un papel importante a favor o en contra de la pacificación del país. En esa labor se presentan problemas éticos y profesionales alrededor de la neutralidad, el manejo del lenguaje y el contexto que se le dé a la información. Las propuestas van orientadas hacia el trabajo periodístico en beneficio de la pacificación del país.

  20. 78 FR 57623 - TRICARE Over-the-Counter Drug Demonstration Project

    Science.gov (United States)

    2013-09-19

    ... B One-Step (levonorgestrel) emergency contraceptive as an over-the-counter product ``for all women...-Counter Plan B One-Step Emergency Contraceptive (levonorgestrel). (2) OTC availability of Plan B One-Step Emergency Contraceptive (levonorgestrel) through the demonstration project will be at retail dispensing...

  1. La revolución gerencial en la gestión pública

    Directory of Open Access Journals (Sweden)

    Edgar Enrique Martínez Cardenas

    2002-08-01

    Full Text Available El ensayo que se presenta hace referencia a los desarrollos teóricos contemporáneos en lo relacionado con la administración de lo público, tomando como período de referencia las últimas tres décadas. Se pretende demostrar que mas que nuevas formulaciones teóricas, lo que se ha venido dando es la asunción de ciertas prácticas administrativas empresariales enmarcadas todas ellas dentro del concepto de "revolución gerencial" como reacción a la crisis del Estado y a sus opciones de reforma que desde el punto de vista administrativo habían estado hasta entonces enmarcadas Dentro del paradigma burocrático. Sin embargo, al contrario de esta visión, se considera que al menos en países como el nuestro, la tarea no es superar la cultura burocrática, inexistente por lo general entre nosotros, y sustituirla por una cultura gerencial, sino superar el populismo político y el clientelismo de la función pública y sustituirlo por un Estado de Derecho impulsado por una administración genuinamente burocrática responsable del buen desarrollo de las funciones exclusivas y superiores del Estado.

  2. Replacement between conformity and counter-conformity in consumption decisions.

    Science.gov (United States)

    Chou, Ting-Jui; Chang, En-Chung; Dai, Qi; Wong, Veronica

    2013-02-01

    This study assessed, in a Chinese context, how self-esteem interacts with perceived similarity and uniqueness to yield cognitive dissonance, and whether the dissonance leads to self-reported conformity or counter-conformity behavior. Participants were 408 respondents from 4 major Chinese cities (M age = 33.0 yr., SD = 4.3; 48% men). Self-perceptions of uniqueness, similarity, cognitive dissonance, self-esteem and need to behave in conformity or counter-conformity were measured. A theoretical model was assessed in four situations, relating the ratings of self-esteem and perceived similarity/uniqueness to the way other people at a wedding were dressed, and the resultant cognitive dissonance and conformity/ counter-conformity behavior. Regardless of high or low self-esteem, all participants reported cognitive dissonance when they were told that they were dressed extremely similarly to or extremely differently from the other people attending the wedding. However, the conforming/counter-conforming strategies used by participants to resolve the cognitive dissonance differed. When encountering dissonance induced by the perceived extreme uniqueness of dress, participants with low self-esteem tended to say they would dress next time so as to conform with the way others were dressed, while those with high self-esteem indicated they would continue their counter-conformity in attire. When encountering dissonance induced by the perceived extreme similarity to others, both those with high and low self-esteem tended to say they would dress in an unorthodox manner to surprise other people in the future.

  3. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A critical evaluaton is presented of the actual state of investigations and explanations of the resolution and pulse height changes resulted in proportional counters from radiation intensity variations. (author)

  4. Global description of (n,p) - and (n,2n) - activation cross sections within statistical multistep theory

    International Nuclear Information System (INIS)

    Kalka, H.; Torjman, M.; Seeliger, D.; Lopez, R.

    1989-07-01

    A unique description of (n,p) and (n,2n) activation cross sections as well as emission spectra is proposed within a pure multistep approach. Calculations are presented for 8 nuclei (A=47...65) in the incident energy range from zero up to 20 MeV. (author). 42 refs, 5 figs, 1 tab

  5. Risetime discrimination applied to pressurized Xe gas proportional counter for hard x-ray detection

    International Nuclear Information System (INIS)

    Fujii, Masami; Doi, Kosei

    1978-01-01

    A high pressure Xe proportional counter has been developed for hard X-ray observation. This counter has better energy-resolving power than a NaI scintillation counter, and the realization of large area is relatively easy. This counter is constructed with a cylindrical aluminum tube, and this tube can be used at 40 atmospheric pressure. The detection efficiency curves were obtained in relation to gas pressure. It is necessary to reduce impurities in the Xe gas to increase the energy-resolving power of the counter. The increase of gas pressure made the resolving power worse. The characteristics of the counter were stable for at least a few months. The wave form discrimination was applied to reduce the background signals such as pulses caused by charged particles and gamma-ray. This method has been used for normal pressure counter, and in the present study, it was applied for the high pressure counter. It was found that the discrimination method was able to be applied to this case. (Kato, T.)

  6. Analytical applications of N-phenyl-n-butyro hydroxamic and N-p-tolyl-n-butyro hydroxamic acids towards chromium (VI), copper (II), iron (III) and uranium (VI)

    International Nuclear Information System (INIS)

    Elkhadir, A. Y. F.

    2001-05-01

    Two aliphatic hydroxamic acids were prepared; N-phenyl-n-butyro hydroxamic acid and N-p-tolyl-n-butyro hydroxamic acid, by the reaction of β-phenylhydroxylamine and p-tolyl hydroxylamine with n-butyryl chloride. The acids were identified by: their melting points, characteristic reactions with acidic solutions of vanadium (V) and iron (III), infrared spectroscopy, nitrogen content and molecular weight determination. The extractability of these acids towards Cr (VI), Cu (II), Fe (III) and U (VI) were investigated at different pH values and molar acid concentrations. N-phenyl-n- butyro hydroxamic acid has a maximum extraction (98.80%) for Cr (VI) at 4 M H 2 SO 4 , (83.25%) for Cu (II) at pH 6, (99.17%) for Fe (III) at pH 5 and (99.76%) at 4 M HNO 3 for U (VI) respectively. N-p-tolyl-n-butyro hydroxamic acid has a maximum extraction (98.40%) for Cr (VI)at 4 M H 2 SO 4 , (81.30%) for Cu (II) at pH 6, (92.80%) for Fe (III) at pH 5 and (99.64%) for U (VI) at 4 M HNO 3 , respectively. The ratios of the metal to ligands were determined by job method (continuous variation method) and were found to be 1:2 for Cr (VI) and U (VI). (Author)

  7. Analytical applications of N-phenyl-n-butyro hydroxamic and N-p-tolyl-n-butyro hydroxamic acids towards chromium (VI), copper (II), iron (III) and uranium (VI)

    Energy Technology Data Exchange (ETDEWEB)

    Elkhadir, A Y. F. [Department of Chemistry, Faculty of Science, University of Khartoum, Khartoum (Sudan)

    2001-05-01

    Two aliphatic hydroxamic acids were prepared; N-phenyl-n-butyro hydroxamic acid and N-p-tolyl-n-butyro hydroxamic acid, by the reaction of {beta}-phenylhydroxylamine and p-tolyl hydroxylamine with n-butyryl chloride. The acids were identified by: their melting points, characteristic reactions with acidic solutions of vanadium (V) and iron (III), infrared spectroscopy, nitrogen content and molecular weight determination. The extractability of these acids towards Cr (VI), Cu (II), Fe (III) and U (VI) were investigated at different pH values and molar acid concentrations. N-phenyl-n- butyro hydroxamic acid has a maximum extraction (98.80%) for Cr (VI) at 4 M H{sub 2}SO{sub 4}, (83.25%) for Cu (II) at pH 6, (99.17%) for Fe (III) at pH 5 and (99.76%) at 4 M HNO{sub 3} for U (VI) respectively. N-p-tolyl-n-butyro hydroxamic acid has a maximum extraction (98.40%) for Cr (VI)at 4 M H{sub 2} SO{sub 4}, (81.30%) for Cu (II) at pH 6, (92.80%) for Fe (III) at pH 5 and (99.64%) for U (VI) at 4 M HNO{sub 3}, respectively. The ratios of the metal to ligands were determined by job method (continuous variation method) and were found to be 1:2 for Cr (VI) and U (VI). (Author)

  8. The E.P.R. (European Water Pressurized Reactor): a choice from the past that should close future?; L'EPR: un choix du passe qui fermerait l'avenir?

    Energy Technology Data Exchange (ETDEWEB)

    Marignac, Y

    2003-11-15

    The present note discusses, by opening questions, different counter-arguments, of the French energy policy such the attempt to adapt the E.P.R., a technological project conceived in an old policy frame, to actual economical and environmental realities. (N.C.)

  9. Banca pública venezolana: reconfiguración del mapa de financiación al desarrollo nacional

    Directory of Open Access Journals (Sweden)

    Marianela Acuña Ortigoza

    2014-01-01

    Full Text Available Durante el período 2000-2011 se producen en Venezuela cambios institucionales que posibilitan la reconfiguración del mapa de financiación al desarrollo nacional. El nuevo marco constitucional, surgido de la aprobación de la Constitución de la Republica Bolivariana de Venezuela de 1999, los lineamientos establecidos en los Planes de la Nación 2001-2007 y 2007-2013, y la manifestación de contradicciones entre la práctica financiera y los objetivos de política pública, se constituirán en el curso del período, en condicionantes permanentes de las transformaciones institucionales del sistema financiero. El objetivo de esta investigación es explicar los cambios institucionales que se han producido en la banca pública venezolana y los resultados alcanzados en relación a los objetivos de la política económica. Mediante una investigación documental con diseño bibliográfico, se explica la experiencia venezolana de transformación de la banca pública y la política pública definida para producir esos cambios, considerando el uso de la capacidad de apalancamiento del sistema financiero como elemento de democratización financiera y dinamizador del desarrollo nacional. Los resultados de la investigación permiten concluir que durante el período 2000-2011 la política económica venezolana persigue modificar los rasgos distintivos del sistema financiero venezolano, y en particular del sector bancario público, y profundizar las transformaciones gradualmente producidas en el sector, de acuerdo a los objetivos de democratización del capital, incremento de la participación del Estado en la actividad financiera y redireccionamiento de la actividad bancaria a los propósitos del desarrollo nacional.

  10. Analysis of Thermal Stability of Different Counter on 28nm FPGA

    DEFF Research Database (Denmark)

    Gupta, Daizy; Yadav, Amit; Hussain, Dil muhammed Akbar

    2016-01-01

    In this paper we are presenting the power analysis for thermal awareness of different counters. The technique we are using to do the analysis is based on 28 nm FPGA tech-nique. In this work during implementation on FPGA, we are going to analyze thermal stability of different counters in temperatu...... range of 10oC, 30oC, 60oC, 90oC, 120oC. There is 90.36% reduction in leakage power of divide by 2 counter when we scale down the temperature from 120oC to 10oC and 49.61% reduction in leakage power of LFSR up counter when we scale down the temperature from 120oC to 10oC....

  11. Preparation of carrier-free Phosphorus-32 from 31P(n,γ )32P reaction

    International Nuclear Information System (INIS)

    Rafii, H.; Arbab Zavar, H.; Avaz Moghadam, S.

    1999-01-01

    The phosphorus-32 is a widely used radioisotope as as tracer or radioactive source in nuclear medicine, and in many other biotechnical applications. In this paper, preparation of carrier-free P-32 with a high specific activity was studied by 31 P(n, γ) 32 P reaction. The anhydrous KH 2 PO 4 , as a target material, was irradiated in Tehran Nuclear Research Reactor with a neutron flux of 2.5x10 13 n/cm 2 .sec. The P-32 produced as a result of Szilard-Chalmers effect was isolated from the target by a strong anion exchange resin, (Dowex - X 8). The quality control of the product shows a high chemical, and radiochemical purity (>98%) and the increase specific activity depends on the irradiation time

  12. Forensic Speaker Recognition Law Enforcement and Counter-Terrorism

    CERN Document Server

    Patil, Hemant

    2012-01-01

    Forensic Speaker Recognition: Law Enforcement and Counter-Terrorism is an anthology of the research findings of 35 speaker recognition experts from around the world. The volume provides a multidimensional view of the complex science involved in determining whether a suspect’s voice truly matches forensic speech samples, collected by law enforcement and counter-terrorism agencies, that are associated with the commission of a terrorist act or other crimes. While addressing such topics as the challenges of forensic case work, handling speech signal degradation, analyzing features of speaker recognition to optimize voice verification system performance, and designing voice applications that meet the practical needs of law enforcement and counter-terrorism agencies, this material all sounds a common theme: how the rigors of forensic utility are demanding new levels of excellence in all aspects of speaker recognition. The contributors are among the most eminent scientists in speech engineering and signal process...

  13. Effects of a low-energy proton irradiation on n+/p-AlInGaP solar cells

    International Nuclear Information System (INIS)

    Lee, H.S.; Yamaguchi, M.; Ekins-Daukes, N.J.; Khan, A.; Takamoto, T.; Imaizumi, M.; Ohshima, T.; Itoh, H.

    2006-01-01

    For the first time, by deep-level transient spectroscopy, 30keV proton irradiation-induced defects in n + /p-AlInGaP solar cells have been observed. After the 30keV proton irradiation, new deep-level defects such as two majority-carrier (hole) traps HP1 (E V +0.98eV, N T =3.8x10 14 cm -3 ) and HP2, and two minority-carrier (electron) traps EP1 (E C -0.71eV, N T =2.0x10 15 cm -3 ) and EP2 have been observed in p-AlInGaP. The introduction rate of majority-carrier trap center (HP1) is 380cm -1 , which is lower than that (1500cm -1 ) in 100keV proton-irradiated p-InGaP. From the minority-carrier injection annealing for HP1 defect and carrier concentration in 30keV proton-irradiated p-AlInGaP, HP1 defect is likely to act as a recombination center as well as a compensator center

  14. Measurement of body potassium with a whole-body counter: relationship between lean body mass and resting energy expenditure

    International Nuclear Information System (INIS)

    Jensen, M.D.; Braun, J.S.; Vetter, R.J.; Marsh, H.M.

    1988-01-01

    We conducted studies to determine whether the Mayo whole-body counter could be used to measure body potassium, and thus lean body mass (LBM), and whether moderate obesity alters resting energy expenditure when corrected for LBM. Twenty-four nonobese and 18 moderately obese adults underwent body potassium (40K) counting, as well as tritiated water space measurement and indirect calorimetry. LBM values predicted from 40K counting and tritiated water space measurements were highly correlated (P = 0.001; r = 0.88). Resting energy expenditure was closely related to LBM (P less than 0.0001; r = 0.78): kcal/day = 622 kcal + (LBM.20.0 kcal/kg LBM). In this relationship, the obese subjects did not differ from nonobese subjects. In summary, the Mayo whole-body counter can accurately measure LBM, and moderate obesity has no detectable effect on corrected resting energy expenditure

  15. Construction techniques and operation principles of Geiger-Mueller counters using external cathode (Mazetype)

    International Nuclear Information System (INIS)

    Sevegnani, F.X.

    1988-01-01

    The construction techniques for external cathode (Maze) and internal cathode Geiger-Muller counters are described, showing the operation principles and the used material nature. More than 200 counter types were evaluated analysing their characteristics. The influence of several types of guard-rings was studied, for optimizing counter operation conditions. Plateaus of the order of 700 V with slope of 0,3%/100 V for the net counting rate, and 1400 V with a slope of 0,8/100 V for total counts using total pressure of 10 cmHg, were obtained. A counter for β detection, using blown glass window in one of the edges of the cylinder was constructed. Counters of long life using materials such as, mica, adhesive glues, etc., were obtained. The results shown that the best counter operation occurs when it is empty in a vacuum of 10 -5 mmHg. (M.C.K.) [pt

  16. Beam test of Cherenkov counter prototype for ZDF setup

    International Nuclear Information System (INIS)

    Kacharava, A.K.; Macharashvili, G.G.; Nioradze, M.S.; Komarov, V.I.; Sopov, V.S.; Chernyshev, V.P.

    1995-01-01

    We describe a Cherenkov counter of total internal reflection for particle separation in the momentum range where all types of particles radiate Cherenkov light. The Cherenkov counter prototype with the lucite radiator was tested on the secondary beam of the ITEP (Moscow) accelerator. Dependence of the photomultiplier pulse height on the particle entrance angle was clearly observed. 4 refs., 4 figs

  17. Double-scaled disorder in Ga(N,As,P)/GaP multiquantum wells

    International Nuclear Information System (INIS)

    Karcher, C.; Jandieri, K.; Kunert, B.; Fritz, R.; Volz, K.; Stolz, W.; Gebhard, F.; Baranovskii, S.D.; Heimbrodt, W.

    2013-01-01

    The compositional dependence of the properties of metastable Ga(N,As,P) has been characterized optically by means of temperature dependent absorptive and emissive techniques. By assuming a two-scaled disorder within the alloy caused by microscopic composition fluctuations on the one hand and a fluctuation of strain fields or the well width on the other hand, Monte Carlo simulations of the carrier dynamics are in good agreement with the experimental findings. The compositional dependence further reveals an increase of disorder with decreasing nitrogen content. - Highlights: ► Temperature dependent spectral dataset of two Ga(N,As,P)/ MQWs with varying composition. ► High resolution TEM study revealing height fluctuations within the triple QWs. ► Two distinct scales of disorder corresponding to two spatial length scales. ► Almost perfect Monte-Carlo simulations of the experimental findings. ► Theoretical explanation of the discovered reduction of disorder with increasing N.

  18. Formation of definite GaN p-n junction by Mg-ion implantation to n--GaN epitaxial layers grown on a high-quality free-standing GaN substrate

    Science.gov (United States)

    Oikawa, Takuya; Saijo, Yusuke; Kato, Shigeki; Mishima, Tomoyoshi; Nakamura, Tohru

    2015-12-01

    P-type conversion of n--GaN by Mg-ion implantation was successfully performed using high quality GaN epitaxial layers grown on free-standing low-dislocation-density GaN substrates. These samples showed low-temperature PL spectra quite similar to those observed from Mg-doped MOVPE-grown p-type GaN, consisting of Mg related donor-acceptor pair (DAP) and acceptor bound exciton (ABE) emission. P-n diodes fabricated by the Mg-ion implantation showed clear rectifying I-V characteristics and UV and blue light emissions were observed at forward biased conditions for the first time.

  19. A high-efficiency neutron coincidence counter for small samples

    International Nuclear Information System (INIS)

    Miller, M.C.; Menlove, H.O.; Russo, P.A.

    1991-01-01

    The inventory sample coincidence counter (INVS) has been modified to enhance its performance. The new design is suitable for use with a glove box sample-well (in-line application) as well as for use in the standard at-line mode. The counter has been redesigned to count more efficiently and be less sensitive to variations in sample position. These factors lead to a higher degree of precision and accuracy in a given counting period and allow for the practical use of the INVS counter with gamma-ray isotopics to obtain a plutonium assay independent of operator declarations and time-consuming chemicals analysis. A calculation study was performed using the Los Alamos transport code MCNP to optimize the design parameters. 5 refs., 7 figs., 8 tabs

  20. N and P addition inhibits growth of rich fen bryophytes

    DEFF Research Database (Denmark)

    Andersen, Dagmar Kappel; Ejrnæs, Rasmus; Riis, Tenna

    2016-01-01

    vernicosus and paludella squarrosa) rich fen bryophytes were grown in mixed culture and subjected to rainwater or groundwater and three levels of N (0, 1 and 3 mg N L-1) and P (0, 0.05 and 0.1 mg P NL-1). All species responded negatively to higher N-levels and three of four species responded negatively...... to rainwater and higher P-levels. C. cuspidata had highest relative growth rate in all treatments, and the infrequently occurringrare species had lower relative growth rate and were more negatively affected by high levels of N than the frequently occurringcommon species. A negative effect of rainwater seemed...... to be caused by higher background levels of N in rainwater compared to groundwater rather than a pH-effect per se. We found a negative effect of high initial bryophyte density in three of four species indicating density dependent inhibition between species.We suggest that maintenance of oligotrophic conditions...

  1. Crystallization of ornithine acetyltransferase from yeast by counter-diffusion and preliminary X-ray study

    Energy Technology Data Exchange (ETDEWEB)

    Maes, Dominique, E-mail: dominique.maes@vub.ac.be; Crabeel, Marjolaine [Laboratorium voor Ultrastructuur, Vrije Universiteit Brussel (VUB) and Vlaams Interuniversitair Instituut voor Biotechnologie (VIB), Pleinlaan 2, B-1050 Brussels (Belgium); Van de Weerdt, Cécile; Martial, Joseph [Laboratoire de Biologie Moléculaire et de Génie Génétique, Université de Liège, Allée de la Chimie 3, B-4000 Liège (Belgium); Peeters, Eveline; Charlier, Daniël [Erfelijkheidsleer en Microbiologie, Vrije Universiteit Brussel (VUB), Pleinlaan 2, B-1050 Brussels (Belgium); Decanniere, Klaas; Vanhee, Celine; Wyns, Lode; Zegers, Ingrid [Laboratorium voor Ultrastructuur, Vrije Universiteit Brussel (VUB) and Vlaams Interuniversitair Instituut voor Biotechnologie (VIB), Pleinlaan 2, B-1050 Brussels (Belgium)

    2006-12-01

    A study on the crystallization of ornithine acetyltransferase from yeast, catalysing the fifth step in microbial arginine synthesis, is presented. The use of the counter-diffusion technique removes the disorder present in one dimension in crystals grown by either batch or hanging-drop techniques. A study is presented on the crystallization of ornithine acetyltransferase from yeast, which catalyzes the fifth step in microbial arginine synthesis. The use of the counter-diffusion technique removes the disorder present in one dimension in crystals grown by either the batch or hanging-drop techniques. This makes the difference between useless crystals and crystals that allow successful determination of the structure of the protein. The crystals belong to space group P4, with unit-cell parameters a = b = 66.98, c = 427.09 Å, and a data set was collected to 2.76 Å.

  2. On the Performance of Counter-Based Broadcast Scheme for Mobile ...

    African Journals Online (AJOL)

    Despite its simplicity, it can result in high redundant retransmission, contention and collision, a phenomenon collectively referred to as the broadcast storm problem. Counter-based broadcast scheme has been proposed to mitigate this inherent problem and it relies on counter threshold value for rebroadcast decision. Thus ...

  3. Chemical-free n-type and p-type multilayer-graphene transistors

    Energy Technology Data Exchange (ETDEWEB)

    Dissanayake, D. M. N. M., E-mail: nandithad@voxtel-inc.com [Voxtel Inc, Lockey Laboratories, University of Oregon, Eugene Oregon 97402 (United States); Eisaman, M. D. [Sustainable Energy Technologies Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Department of Electrical and Computer Engineering, Stony Brook University, Stony Brook, New York 11794 (United States); Department of Physics and Astronomy, Stony Brook University, Stony Brook, New York 11794 (United States)

    2016-08-01

    A single-step doping method to fabricate n- and p-type multilayer graphene (MG) top-gate field effect transistors (GFETs) is demonstrated. The transistors are fabricated on soda-lime glass substrates, with the n-type doping of MG caused by the sodium in the substrate without the addition of external chemicals. Placing a hydrogen silsesquioxane (HSQ) barrier layer between the MG and the substrate blocks the n-doping, resulting in p-type doping of the MG above regions patterned with HSQ. The HSQ is deposited in a single fabrication step using electron beam lithography, allowing the patterning of arbitrary sub-micron spatial patterns of n- and p-type doping. When a MG channel is deposited partially on the barrier and partially on the glass substrate, a p-type and n-type doping profile is created, which is used for fabricating complementary transistors pairs. Unlike chemically doped GFETs in which the external dopants are typically introduced from the top, these substrate doped GFETs allow for a top gate which gives a stronger electrostatic coupling to the channel, reducing the operating gate bias. Overall, this method enables scalable fabrication of n- and p-type complementary top-gated GFETs with high spatial resolution for graphene microelectronic applications.

  4. Electronic device for measuring the polarization parameter in the {pi}{sup -}p {yields} {pi}{sup 0}n charge exchange reaction on a polarized proton target; Un appareillage electronique destine a la mesure du parametre de polarisation dans la reaction d'echange de charge {pi}{sup -}p {yields} {pi}{sup 0}n sur cible de protons polarises

    Energy Technology Data Exchange (ETDEWEB)

    Brehin, S [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-12-15

    An electronic apparatus has been constructed to measure the polarization parameter P{sub 0}(t) in {pi}{sup -}p {yields} {pi}{sup 0}n charge exchange scattering at 5.9 GeV/c and 11,2 GeV/c on polarized proton target. This device insures triggering of a heavy plate spark chamber, allowing visualisation of {gamma} rays from the {pi}{sup 0} decays when the associated neutron offers suitable characteristics in direction and energy. The neutron is detected by an array of 32 counters and his energy is measured by a time of flight method. Electronic circuits of this apparatus are described as test and calibration methods used. (author) [French] Un appareillage electronique a ete realise pour mesurer le parametre de polarisation P{sub 0}(t) dans la reaction d'echange de charge {pi}{sup -}p {yields} {pi}{sup 0}n a 5,9 GeV/c et 11,2 GeV/c sur une cible de protons polarises. Ce dispositif assure le declenchement d'une chambre a etincelles a plaques lourdes, permettant de visualiser les {gamma} de desitegration du {pi}{sup 0}, lorsque le neutron associe presente les caracteristiques convenables en direction et en energie. Le neutron est detecte par un ensemble de 32 compteurs et son energie est mesuree par une methode de temps de vol. Les circuits composant cet appareillage sont decrits ainsi que les methodes d'etalonnage et de verification utilisees. (auteur)

  5. Electronic device for measuring the polarization parameter in the {pi}{sup -}p {yields} {pi}{sup 0}n charge exchange reaction on a polarized proton target; Un appareillage electronique destine a la mesure du parametre de polarisation dans la reaction d'echange de charge {pi}{sup -}p {yields} {pi}{sup 0}n sur cible de protons polarises

    Energy Technology Data Exchange (ETDEWEB)

    Brehin, S. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-12-15

    An electronic apparatus has been constructed to measure the polarization parameter P{sub 0}(t) in {pi}{sup -}p {yields} {pi}{sup 0}n charge exchange scattering at 5.9 GeV/c and 11,2 GeV/c on polarized proton target. This device insures triggering of a heavy plate spark chamber, allowing visualisation of {gamma} rays from the {pi}{sup 0} decays when the associated neutron offers suitable characteristics in direction and energy. The neutron is detected by an array of 32 counters and his energy is measured by a time of flight method. Electronic circuits of this apparatus are described as test and calibration methods used. (author) [French] Un appareillage electronique a ete realise pour mesurer le parametre de polarisation P{sub 0}(t) dans la reaction d'echange de charge {pi}{sup -}p {yields} {pi}{sup 0}n a 5,9 GeV/c et 11,2 GeV/c sur une cible de protons polarises. Ce dispositif assure le declenchement d'une chambre a etincelles a plaques lourdes, permettant de visualiser les {gamma} de desitegration du {pi}{sup 0}, lorsque le neutron associe presente les caracteristiques convenables en direction et en energie. Le neutron est detecte par un ensemble de 32 compteurs et son energie est mesuree par une methode de temps de vol. Les circuits composant cet appareillage sont decrits ainsi que les methodes d'etalonnage et de verification utilisees. (auteur)

  6. Dual ohmic contact to N- and P-type silicon carbide

    Science.gov (United States)

    Okojie, Robert S. (Inventor)

    2013-01-01

    Simultaneous formation of electrical ohmic contacts to silicon carbide (SiC) semiconductor having donor and acceptor impurities (n- and p-type doping, respectively) is disclosed. The innovation provides for ohmic contacts formed on SiC layers having n- and p-doping at one process step during the fabrication of the semiconductor device. Further, the innovation provides a non-discriminatory, universal ohmic contact to both n- and p-type SiC, enhancing reliability of the specific contact resistivity when operated at temperatures in excess of 600.degree. C.

  7. Open-gated pH sensor fabricated on an undoped-AlGaN/GaN HEMT structure.

    Science.gov (United States)

    Abidin, Mastura Shafinaz Zainal; Hashim, Abdul Manaf; Sharifabad, Maneea Eizadi; Rahman, Shaharin Fadzli Abd; Sadoh, Taizoh

    2011-01-01

    The sensing responses in aqueous solution of an open-gated pH sensor fabricated on an AlGaN/GaN high-electron-mobility-transistor (HEMT) structure are investigated. Under air-exposed ambient conditions, the open-gated undoped AlGaN/GaN HEMT only shows the presence of a linear current region. This seems to show that very low Fermi level pinning by surface states exists in the undoped AlGaN/GaN sample. In aqueous solution, typical current-voltage (I-V) characteristics with reasonably good gate controllability are observed, showing that the potential of the AlGaN surface at the open-gated area is effectively controlled via aqueous solution by the Ag/AgCl gate electrode. The open-gated undoped AlGaN/GaN HEMT structure is capable of distinguishing pH level in aqueous electrolytes and exhibits linear sensitivity, where high sensitivity of 1.9 mA/pH or 3.88 mA/mm/pH at drain-source voltage, V(DS) = 5 V is obtained. Due to the large leakage current where it increases with the negative gate voltage, Nernstian like sensitivity cannot be determined as commonly reported in the literature. This large leakage current may be caused by the technical factors rather than any characteristics of the devices. Surprisingly, although there are some imperfections in the device preparation and measurement, the fabricated devices work very well in distinguishing the pH levels. Suppression of current leakage by improving the device preparation is likely needed to improve the device performance. The fabricated device is expected to be suitable for pH sensing applications.

  8. Open-Gated pH Sensor Fabricated on an Undoped-AlGaN/GaN HEMT Structure

    Directory of Open Access Journals (Sweden)

    Taizoh Sadoh

    2011-03-01

    Full Text Available The sensing responses in aqueous solution of an open-gated pH sensor fabricated on an AlGaN/GaN high-electron-mobility-transistor (HEMT structure are investigated. Under air-exposed ambient conditions, the open-gated undoped AlGaN/GaN HEMT only shows the presence of a linear current region. This seems to show that very low Fermi level pinning by surface states exists in the undoped AlGaN/GaN sample. In aqueous solution, typical current-voltage (I-V characteristics with reasonably good gate controllability are observed, showing that the potential of the AlGaN surface at the open-gated area is effectively controlled via aqueous solution by the Ag/AgCl gate electrode. The open-gated undoped AlGaN/GaN HEMT structure is capable of distinguishing pH level in aqueous electrolytes and exhibits linear sensitivity, where high sensitivity of 1.9 mA/pH or 3.88 mA/mm/pH at drain-source voltage, VDS = 5 V is obtained. Due to the large leakage current where it increases with the negative gate voltage, Nernstian like sensitivity cannot be determined as commonly reported in the literature. This large leakage current may be caused by the technical factors rather than any characteristics of the devices. Surprisingly, although there are some imperfections in the device preparation and measurement, the fabricated devices work very well in distinguishing the pH levels. Suppression of current leakage by improving the device preparation is likely needed to improve the device performance. The fabricated device is expected to be suitable for pH sensing applications.

  9. Losing the Plot: Narrative, Counter-Narrative and Violent Extremism

    Directory of Open Access Journals (Sweden)

    Andrew Glazzard

    2017-05-01

    Full Text Available Counter-terrorist practitioners and policy makers appear to be very interested in narrative. They often describe the worldview of violent Islamist groups and movements as the ‘jihadi narrative’, while their efforts to confront terrorist propaganda are usually labelled as ‘counter-narrative’ or ‘alternative narrative’. However, while the counter-narrative approach has gained widespread acceptance in governments, think-tanks and civil society organisations, it is built on very shaky theoretical and empirical foundations. Some valuable theoretical contributions to the study of violent extremist narrative have been made by psychologists in particular, but there is one discipline which is conspicuous by its absence from the field: literary studies. This paper makes a case for the value of studying violent extremist narratives as narratives in the literary sense. By employing the tools and techniques of literary criticism, violent extremist communication can be revealed as not only potentially persuasive, but also creative and aesthetically appealing: terrorists inspire their followers, they don’t merely persuade them. Understanding the creative sources of this inspiration is vital if counter-narrative is to succeed in presenting an alternative to the propaganda of violent extremist groups.

  10. Alternative modes for optical trapping and manipulation using counter-propagating shaped beams

    International Nuclear Information System (INIS)

    Palima, D; Tauro, S; Glückstad, J; Lindballe, T B; Kristensen, M V; Stapelfeldt, H; Keiding, S R

    2011-01-01

    Counter-propagating beams have enabled the first stable three-dimensional optical trapping of microparticles and this procedure has been enhanced and developed over the years to achieve independent and interactive manipulation of multiple particles. In this work, we analyse counter-propagating shaped-beam traps that depart from the conventional geometry based on symmetric, coaxial counter-propagating beams. We show that projecting shaped beams with separation distances previously considered axially unstable can, in fact, enhance the axial and transverse trapping stiffnesses. We also show that deviating from using perfectly counter-propagating beams to use oblique beams can improve the axial stability of the traps and improve the axial trapping stiffness. These alternative geometries can be particularly useful for handling larger particles. These results hint at a rich potential for light shaping for optical trapping and manipulation using patterned counter-propagating beams, which still remains to be fully tapped

  11. Which future for nuclear counter-proliferation?

    International Nuclear Information System (INIS)

    Duval, M.

    2010-01-01

    Dealing with the case of nuclear weapons possessed by nuclear states (but not eventually by terrorists), the author first identifies the constants of counter-proliferation: it is linked to interest conflicts between those who try to preserve their monopoly and those who try to acquire a new weapon either because of a threat or for reasons of regional prestige, the evolution from use to deterrence, the appearance of new actors after the USA and Russia, the role of nuclear tactical weapons, and the future of Russian weapons and know-how. He presents the international counter-proliferation context: the Non Proliferation Treaty (NPT), the IAEA and its controls, the Nuclear Supplier Group (NSG), the nuclear-free zones, the Comprehensive Test Ban Treaty (CTBT), the Missile Technology Control Regime (MTCR). He describes how and why proliferation occurs: uranium enrichment and plutonium technology, political reasons in different parts of the world. Then, he gives an overview of the proliferation status by commenting the cases of Israel, Iraq, India, Pakistan, North Korea, and Iran. He discusses the future of proliferation (involved countries, existence of a nuclear black market) and of counter-proliferation as far as Middle-East and North Korea are concerned. He tries finally to anticipate the consequences for nuclear deterrence strategy, and more particularly for Europe and France

  12. Horizontal Assembly of Single Nanowire Diode Fabricated by p-n Junction GaN NW Grown by MOCVD

    Directory of Open Access Journals (Sweden)

    Ji-Hyeon Park

    2014-01-01

    Full Text Available Uniaxially p-n junction gallium nitride nanowires have been synthesized via metal-organic chemical vapor deposition method. Nanowires prepared on Si(111 substrates were found to grow perpendicular to the substrate, and the transmission electron microscopy studies demonstrated that the nanowires had singlecrystalline structures with a growth axis. The parallel assembly of the p-n junction nanowire was prepared on a Si substrate with a thermally grown SiO2 layer. The transport studies of horizontal gallium nitride nanowire structures assembled from p- and n-type materials show that these junctions correspond to well-defined p-n junction diodes. The p-n junction devices based on GaN nanowires suspended over the electrodes were fabricated and their electrical properties were investigated. The horizontally assembled gallium nitride nanowire diodes suspended over the electrodes exhibited a substantial increase in conductance under UV light exposure. Apart from the selectivity to different light wavelengths, high responsivity and extremely short response time have also been obtained.

  13. Suppression and utilization of spurious pulse occurence in organic GM-counters

    International Nuclear Information System (INIS)

    Narita, Y.; Igarashi, R.; Akagami, H.; Ozawa, Y.

    1979-01-01

    The authors have made a study of suppression and utilization of spurious pulse occurrence in organic GM-counters. Almost all spurious pulses in the organic GM-counter are the delayed pulses which occur being dependent upon the radiation intensity. The occurrence rate of the delayed pulses against the radiation intensity is affected by the intensity of the electric field in the vicinity of the cathode of the GM-counter. The occurrence of the delayed pulses can be suppressed when the electric field in the vicinity of the cathode is kept at high value. On the contrary, the occurrence of the delayed pulses can be utilized for the dosimetry of the pulsed radiation by means of increasing the space of the weak electric field in the GM-counter. (Auth.)

  14. Using Counter-Stories to Challenge Stock Stories about Traveller Families

    Science.gov (United States)

    D'Arcy, Kate

    2017-01-01

    Critical Race Theory (CRT) is formed from a series of different methodological tools to expose and address racism and discrimination. Counter-stories are one of these tools. This article considers the potential of counter-stories as a methodological, theoretical and practical tool to analyse existing educational inequalities for Traveller…

  15. Counter-Leadership Targeting and Conflict Termination

    National Research Council Canada - National Science Library

    Taylor, Bradly

    1999-01-01

    .... Can the leader be found? And, is it legal and ethical to attack the leader? Analysis rarely has been conducted to determine whether the targeted organization is vulnerable to Counter Leadership Targeting (CLT...

  16. An acoustical bubble counter for superheated drop detectors

    International Nuclear Information System (INIS)

    Taylor, C.; Montvila, D.; Flynn, D.; Brennan, C.; D'Errico, F.

    2006-01-01

    A new bubble counter has been developed based on the well-established approach of detecting vaporization events acoustically in superheated drop detectors (SDDs). This counter is called the Framework Scientific ABC 1260, and it represents a major improvement over prior versions of this technology. By utilizing advanced acoustic pattern recognition software, the bubble formation event can be differentiated from ambient background noise, as well as from other acoustic signatures. Additional structural design enhancements include a relocation of the electronic components to the bottom of the device; thus allowing for greater stability, easier access to vial SDDs without exposure to system electronics. Upgrades in the electronics permit an increase in the speed of bubble detection by almost 50%, compared with earlier versions of the counters. By positioning the vial on top of the device, temperature and sound insulation can be accommodated for extreme environments. Lead shells can also be utilized for an enhanced response to high-energy neutrons. (authors)

  17. An acoustical bubble counter for superheated drop detectors.

    Science.gov (United States)

    Taylor, Chris; Montvila, Darius; Flynn, David; Brennan, Christopher; d'Errico, Francesco

    2006-01-01

    A new bubble counter has been developed based on the well-established approach of detecting vaporization events acoustically in superheated drop detectors (SDDs). This counter is called the Framework Scientific ABC 1260, and it represents a major improvement over prior versions of this technology. By utilizing advanced acoustic pattern recognition software, the bubble formation event can be differentiated from ambient background noise, as well as from other acoustic signatures. Additional structural design enhancements include a relocation of the electronic components to the bottom of the device; thus allowing for greater stability, easier access to vial SDDs without exposure to system electronics. Upgrades in the electronics permit an increase in the speed of bubble detection by almost 50%, compared with earlier versions of the counters. By positioning the vial on top of the device, temperature and sound insulation can be accommodated for extreme environments. Lead shells can also be utilized for an enhanced response to high-energy neutrons.

  18. Comparación de los interpoladores IDW Y Kriging en la variación espacial de pH, Ca, CICE y P del suelo

    Directory of Open Access Journals (Sweden)

    Mario Villatoro

    2008-01-01

    Full Text Available Con el objetivo de comparar los interpoladores Kriging y el IDW (Inverse Distance Weighting, por ser los más utilizados en los estudios de análisis de la variación espacial, en un área de 2 467 m2 se procedió a georeferenciar 61 puntos a una distancia de 3,5 m entre sí. Se tomó muestras de suelo a una profundidad de 0-15 cm en cada uno de los puntos. El programa GS+ para Windows se usó en los análisis de variogramas, interpolación y validación cruzada. Con valores de pH, Ca, CICE y P del suelo, se procedió a las interpolaciones. Con el Kriging se calculó los semivariogramas y también se determinó que el modelo esférico fue el de mejor ajuste. Como medidas de precisión se calculó el promedio absoluto del error (PAE y el promedio del cuadrado del error (PCE; y, como medida de efectividad, el estimado de efectividad de predicción (E. Aunque ambos interpoladores tuvieron un desempeño similar, el Kriging fue superior al predecir de una mejor manera la variación de pH, Ca, y CICE, mientras que el IDW lo fue con el P.

  19. 15N Hyperpolarization of Imidazole-15N2 for Magnetic Resonance pH Sensing via SABRE-SHEATH.

    Science.gov (United States)

    Shchepin, Roman V; Barskiy, Danila A; Coffey, Aaron M; Theis, Thomas; Shi, Fan; Warren, Warren S; Goodson, Boyd M; Chekmenev, Eduard Y

    2016-06-24

    15 N nuclear spins of imidazole- 15 N 2 were hyperpolarized using NMR signal amplification by reversible exchange in shield enables alignment transfer to heteronuclei (SABRE-SHEATH). A 15 N NMR signal enhancement of ∼2000-fold at 9.4 T is reported using parahydrogen gas (∼50% para-) and ∼0.1 M imidazole- 15 N 2 in methanol:aqueous buffer (∼1:1). Proton binding to a 15 N site of imidazole occurs at physiological pH (p K a ∼ 7.0), and the binding event changes the 15 N isotropic chemical shift by ∼30 ppm. These properties are ideal for in vivo pH sensing. Additionally, imidazoles have low toxicity and are readily incorporated into a wide range of biomolecules. 15 N-Imidazole SABRE-SHEATH hyperpolarization potentially enables pH sensing on scales ranging from peptide and protein molecules to living organisms.

  20. Design and characterization of GaN p-i-n diodes for betavoltaic devices

    Science.gov (United States)

    Khan, Muhammad R.; Smith, Joshua R.; Tompkins, Randy P.; Kelley, Stephen; Litz, Marc; Russo, John; Leathersich, Jeff; Shahedipour-Sandvik, Fatemeh (Shadi); Jones, Kenneth A.; Iliadis, Agis

    2017-10-01

    The performance of gallium nitride (GaN) p-i-n diodes were investigated for use as a betavoltaic device. Dark IV measurements showed a turn on-voltage of approximately 3.2 V, specific-on-resistance of 15.1 mΩ cm2 and a reverse leakage current of -0.14 mA/cm2 at -10 V. A clear photo-response was observed when IV curves were measured under a light source at a wavelength of 310 nm (4.0 eV). In addition, GaN p-i-n diodes were tested under an electron-beam in order to simulate common beta radiation sources ranging from that of 3H (5.6 keV average) to 63Ni (17 keV average). From this data, we estimated output powers of 53 nW and 750 nW with overall efficiencies of 0.96% and 4.4% for our device at incident electron energies of 5.6 keV and 17 keV corresponding to 3H and 63Ni beta sources respectively.