WorldWideScience

Sample records for oxygen saturation change

  1. Comparison of pulseoximetry oxygen saturation and arterial oxygen saturation in open heart intensive care unit

    Directory of Open Access Journals (Sweden)

    Alireza Mahoori

    2013-08-01

    Full Text Available Background: Pulseoximetry is widely used in the critical care setting, currently used to guide therapeutic interventions. Few studies have evaluated the accuracy of SPO2 (puls-eoximetry oxygen saturation in intensive care unit after cardiac surgery. Our objective was to compare pulseoximetry with arterial oxygen saturation (SaO2 during clinical routine in such patients, and to examine the effect of mild acidosis on this relationship.Methods: In an observational prospective study 80 patients were evaluated in intensive care unit after cardiac surgery. SPO2 was recorded and compared with SaO2 obtained by blood gas analysis. One or serial arterial blood gas analyses (ABGs were performed via a radial artery line while a reliable pulseoximeter signal was present. One hundred thirty seven samples were collected and for each blood gas analyses, SaO2 and SPO2 we recorded.Results: O2 saturation as a marker of peripheral perfusion was measured by Pulseoxim-etry (SPO2. The mean difference between arterial oxygen saturation and pulseoximetry oxygen saturation was 0.12%±1.6%. A total of 137 paired readings demonstrated good correlation (r=0.754; P<0.0001 between changes in SPO2 and those in SaO2 in samples with normal hemoglobin. Also in forty seven samples with mild acidosis, paired readings demonstrated good correlation (r=0.799; P<0.0001 and the mean difference between SaO2 and SPO2 was 0.05%±1.5%.Conclusion: Data showed that in patients with stable hemodynamic and good signal quality, changes in pulseoximetry oxygen saturation reliably predict equivalent changes in arterial oxygen saturation. Mild acidosis doesn’t alter the relation between SPO2 and SaO2 to any clinically important extent. In conclusion, the pulse oximeter is useful to monitor oxygen saturation in patients with stable hemodynamic.

  2. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriëtte; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michaël A.; Spronk, Peter E.

    2012-01-01

    Objective: The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design: Prospective observational controlled study. Setting: Nonacademic university-affiliated

  3. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriette; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michael A.; Spronk, Peter E.

    2012-01-01

    Objective:  The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design:  Prospective observational controlled study. Setting:  Nonacademic university-affiliated

  4. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    International Nuclear Information System (INIS)

    Kyriacou, P A; Shafqat, K; Pal, S K

    2007-01-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO 2 ) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO 2 ) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO 2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  5. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Science.gov (United States)

    Kyriacou, P. A.; Shafqat, K.; Pal, S. K.

    2007-10-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO2) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  6. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Kyriacou, P A [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Shafqat, K [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Pal, S K [St Andrew' s Centre for Plastic Surgery and Burns, Broomfield Hospital, Chelmsford, CM1 7ET (United Kingdom)

    2007-10-15

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO{sub 2}) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO{sub 2}) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO{sub 2} sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures

  7. Changes in retinal oxygen saturation after intravitreal aflibercept in patients with diabetic macular edema

    DEFF Research Database (Denmark)

    Blindbæk, Søren Leer; Peto, Tunde; Grauslund, Jakob

    2017-01-01

    Design of study: Three months prospective interventional study. Purpose: To evaluate changes in retinal arterial and venous oxygen saturation after intravitreal aflibercept in patients with diabetic macular edema (DME). Methods: We included 17 patients with DME, central retinal thickness (CRT) >300...

  8. Brain oxygen saturation assessment in neonates using T2-prepared blood imaging of oxygen saturation and near-infrared spectroscopy

    DEFF Research Database (Denmark)

    Alderliesten, Thomas; De Vis, Jill B; Lemmers, Petra Ma

    2017-01-01

    saturation in the sagittal sinus (R(2 )= 0.49, p = 0.023), but no significant correlations could be demonstrated with frontal and whole brain cerebral blood flow. These results suggest that measuring oxygen saturation by T2-prepared blood imaging of oxygen saturation is feasible, even in neonates. Strong...... sinus. A strong linear relation was found between the oxygen saturation measured by magnetic resonance imaging and the oxygen saturation measured by near-infrared spectroscopy (R(2 )= 0.64, p ..., and magnetic resonance imaging measures of frontal cerebral blood flow, whole brain cerebral blood flow and venous oxygen saturation in the sagittal sinus (R(2 )= 0.71, 0.50, 0.65; p 

  9. Monitor hemoglobin concentration and oxygen saturation in living mouse tail using photoacoustic CT scanner

    Science.gov (United States)

    Liu, Bo; Kruger, Robert; Reinecke, Daniel; Stantz, Keith M.

    2010-02-01

    Purpose: The purpose of this study is to use PCT spectroscopy scanner to monitor the hemoglobin concentration and oxygen saturation change of living mouse by imaging the artery and veins in a mouse tail. Materials and Methods: One mouse tail was scanned using the PCT small animal scanner at the isosbestic wavelength (796nm) to obtain its hemoglobin concentration. Immediately after the scan, the mouse was euthanized and its blood was extracted from the heart. The true hemoglobin concentration was measured using a co-oximeter. Reconstruction correction algorithm to compensate the acoustic signal loss due to the existence of bone structure in the mouse tail was developed. After the correction, the hemoglobin concentration was calculated from the PCT images and compared with co-oximeter result. Next, one mouse were immobilized in the PCT scanner. Gas with different concentrations of oxygen was given to mouse to change the oxygen saturation. PCT tail vessel spectroscopy scans were performed 15 minutes after the introduction of gas. The oxygen saturation values were then calculated to monitor the oxygen saturation change of mouse. Results: The systematic error for hemoglobin concentration measurement was less than 5% based on preliminary analysis. Same correction technique was used for oxygen saturation calculation. After correction, the oxygen saturation level change matches the oxygen volume ratio change of the introduced gas. Conclusion: This living mouse tail experiment has shown that NIR PCT-spectroscopy can be used to monitor the oxygen saturation status in living small animals.

  10. Misconceptions in Reporting Oxygen Saturation

    NARCIS (Netherlands)

    Toffaletti, John; Zijlstra, Willem G.

    2007-01-01

    BACKGROUND: We describe some misconceptions that have become common practice in reporting blood gas and cooximetry results. In 1980, oxygen saturation was incorrectly redefined in a report of a new instrument for analysis of hemoglobin (Hb) derivatives. Oxygen saturation (sO(2)) was redefined as the

  11. Investigating tissue respiration and skin microhaemocirculation under adaptive changes and the synchronization of blood flow and oxygen saturation rhythms

    International Nuclear Information System (INIS)

    Dunaev, A V; Palmer, S G; Stewart, N A; Sokolovski, S G; Rafailov, E U; Sidorov, V V; Krupatkin, A I; Rafailov, I E

    2014-01-01

    Multi-functional laser non-invasive diagnostic systems allow the study of a number of microcirculatory parameters, including index of blood microcirculation (I m ) (by laser Doppler flowmetry, LDF) and oxygen saturation (S t O 2 ) of skin tissue (by tissue reflectance oximetry, TRO). This research aimed to use such a system to investigate the synchronization of microvascular blood flow and oxygen saturation rhythms under normal and adaptive change conditions. Studies were conducted on eight healthy volunteers of 21–49 years. These volunteers were observed between one and six months, totalling 422 basic tests (3 min each). Measurements were performed on the palmar surface of the right middle finger and the lower forearm's medial surface. Rhythmic oscillations of LDF and TRO were studied using wavelet analysis. Combined tissue oxygen consumption data for all volunteers during ‘adaptive changes’ increased relative to normal conditions with and without arteriovenous anastomoses. Data analysis revealed resonance and synchronized rhythms in microvascular blood flow and oxygen saturation as an adaptive change in myogenic oscillation (vasomotion) resulting from exercise and possibly psychoemotional stress. Synchronization of myogenic rhythms during adaptive changes may lead to increased oxygen consumption as a result of increased microvascular blood flow velocity. (paper)

  12. Retinal Vessel Oxygen Saturation during 100% Oxygen Breathing in Healthy Individuals.

    Directory of Open Access Journals (Sweden)

    Olof Birna Olafsdottir

    Full Text Available To detect how systemic hyperoxia affects oxygen saturation in retinal arterioles and venules in healthy individuals.Retinal vessel oxygen saturation was measured in 30 healthy individuals with a spectrophotometric retinal oximeter (Oxymap T1. Oximetry was performed during breathing of room air, 100% oxygen (10 minutes, 6L/min and then again room air (10 minutes recovery.Mean oxygen saturation rises modestly in retinal arterioles during 100% oxygen breathing (94.5%±3.8 vs. 92.0%±3.7% at baseline, p<0.0001 and dramatically in retinal venules (76.2%±8.0% vs. 51.3%±5.6%, p<0.0001. The arteriovenous difference decreased during 100% oxygen breathing (18.3%±9.0% vs. 40.7%±5.7%, p<0.0001. The mean diameter of arterioles decreased during 100% oxygen breathing compared to baseline (9.7±1.4 pixels vs. 10.3±1.3 pixels, p<0.0001 and the same applies to the mean venular diameter (11.4±1.2 pixels vs. 13.3±1.5 pixels, p<0.0001.Breathing 100% oxygen increases oxygen saturation in retinal arterioles and more so in venules and constricts them compared to baseline levels. The dramatic increase in oxygen saturation in venules reflects oxygen flow from the choroid and the unusual vascular anatomy and oxygen physiology of the eye.

  13. Retinopathy of prematurity and induced changes in arterial oxygen saturation with near infrared spectrophotometry: a retrospective cohort study

    Science.gov (United States)

    von Siebenthal, K.; Keel, M.; Dietz, V.; Fauchere, J. C.; Martin, X.; Wolf, Martin; Duc, G.; Bucher, H. U.

    1996-10-01

    Near-infrared spectrophotometry (NIRS) is a noninvasive method for measuring oxygenated and deoxygenated hemoglobin in the neonatal brain. Using oxygen as a tracer, it is possible to calculate cerebral blood flow (cbf) and hemoglobin concentration (cHbc), which corresponds to cerebral blood volume, by inducing small changes in arterial oxygen saturation. Variability of tcpO2 is considered to be associated with severe retinopathy of prematurity (ROP). A preliminary analysis without control found a 51 percent incidence of ROP in infants subjected to NIRS measurements whereas among infants who were not exposed to oxygen changes, only 29 percent developed ROP. A controlled study with matched pairs was performed. Thirty-nine premature newborns who had received NIRS recordings were matched with 39 out of 172 infants who had not received NIRS. Using this controlled study design there was no difference in the incidence and severity of ROP between the two groups. The conclusions are that: 1) small changes in oxygen saturation of 3 to 10 percent to measure cbf and cHbc did not increase the incidence or the degree of severity of ROP. 2) A controlled study design is important. Analyses of uncontrolled data would have led to the conclusion that oxygen changes as used with NIRS increase the risk of ROP.

  14. Optimal oxygen saturation in premature infants

    Directory of Open Access Journals (Sweden)

    Meayoung Chang

    2011-09-01

    Full Text Available There is a delicate balance between too little and too much supplemental oxygen exposure in premature infants. Since underuse and overuse of supplemental oxygen can harm premature infants, oxygen saturation levels must be monitored and kept at less than 95% to prevent reactive oxygen species-related diseases, such as retinopathy of prematurity and bronchopulmonary dysplasia. At the same time, desaturation below 80 to 85% must be avoided to prevent adverse consequences, such as cerebral palsy. It is still unclear what range of oxygen saturation is appropriate for premature infants; however, until the results of further studies are available, a reasonable target for pulse oxygen saturation (SpO2 is 90 to 93% with an intermittent review of the correlation between SpO2 and the partial pressure of arterial oxygen tension (PaO2. Because optimal oxygenation depends on individuals at the bedside making ongoing adjustments, each unit must define an optimal target range and set alarm limits according to their own equipment or conditions. All staff must be aware of these values and adjust the concentration of supplemental oxygen frequently.

  15. TECHNIQUES OF EVALUATION OF HEMOGLOBIN OXYGEN SATURATION IN CLINICAL OPHTHALMOLOGY

    Directory of Open Access Journals (Sweden)

    S. Yu. Petrov

    2016-01-01

    Full Text Available Oxygen content in body fluids and tissues is an important indicator of life support functions. A number of ocular pathologies, e.g. glaucoma, are of presumable vascular origin which means altered blood supply and oxygen circulation. Most oxygen is transported in the blood in the association with hemoglobin. When passing through the capillaries, hemoglobin releases oxygen, converting from oxygenated form to deoxygenated form. This process is accompanied by the changes in spectral characteristics of hemoglobin which result in different colors of arterial and venous blood. Photometric technique for the measurement of oxygen saturation in blood is based on the differences in light absorption by different forms of hemoglobin. The measurement of saturation is called oximetry. Pulse oximetry with assessment of tissue oxygenation is the most commonly used method in medicine. The degree of hemoglobin oxygen saturation in the eye blood vessels is the most accessible for noninvasive studies during ophthalmoscopy and informative. Numerous studies showed the importance of this parameter for the diagnosis of retinopathy of various genesis, metabolic status analysis in hyperglycemia, diagnosis and control of treatment of glaucoma and other diseases involving alterations in eye blood supply. The specific method for evaluation of oxygen concentration is the measurement of pressure of oxygen dissolved in the blood, i.e. partial pressure of oxygen. In ophthalmological practice, this parameter is measured in anterior chamber fluid evaluating oxygen level for several ophthalmopathies including different forms of glaucoma, for instillations of hypotensive eye drops as well as in vitreous body near to the optic disc under various levels of intraocular pressure. Currently, monitoring of oxygen saturation in retinal blood vessels, i.e. retinal oximetry, is well developed. This technique is based on the assessment of light absorption by blood depending on

  16. The relationship between cerebral oxygen saturation changes and post operative neurologic complications in patients undergoing cardiac surgery

    International Nuclear Information System (INIS)

    Negargar, S.; Mahmoudpour, A.; Taheri, R.; Sarvin, S.

    2007-01-01

    To study the relationship between cerebral oxygen saturation changes and postoperative neurologic complications. Seventy two adult patients with ASA class II, III who were scheduled for elective cardiac surgery, were randomized into three groups: Group I: with CPB (on -pump) Group II: without CPB (off- pump) Group III: valve surgery. Neuropsychological outcome was assessed by the Mini-Mental State Examination (MMSE). Cerebral oxygen saturation was also measured. There was no statistical difference in desaturation of more than 20% among three groups (P=0.113) but it was significant between group I and II (P=0.042). Changes of rSo/sub 2/ in different hours of surgery was significant in group I and group II (P=0.0001 in both) but it was not significant in group III ( P=0.075) . Although cerebral oximetry is a noninvasive and useful method of monitoring during cardiac surgery, it has low accuracy to determine postoperative neurologic complications. (author)

  17. Retinal oxygen saturation before and after glaucoma surgery.

    Science.gov (United States)

    Nitta, Eri; Hirooka, Kazuyuki; Shimazaki, Takeru; Sato, Shino; Ukegawa, Kaori; Nakano, Yuki; Tsujikawa, Akitaka

    2017-08-01

    This study compared retinal vessel oxygen saturation before and after glaucoma surgery. Retinal oxygen saturation in glaucoma patients was measured using a non-invasive spectrophotometric retinal oximeter. Adequate image quality was found in 49 of the 108 consecutive glaucoma patients recruited, with 30 undergoing trabeculectomy, 11 EX-PRESS and eight trabeculotomy. Retinal oxygen saturation measurements in the retinal arterioles and venules were performed at 1 day prior to and at approximately 10 days after surgery. Statistical analysis was performed using a Student's t-test. After glaucoma surgery, intraocular pressure (IOP) decreased from 19.8 ± 7.7 mmHg to 9.0 ± 5.7 mmHg (p glaucoma surgery had an effect on the retinal venous oxygen saturation. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  18. Relating oxygen partial pressure, saturation and content: the haemoglobin-oxygen dissociation curve.

    Science.gov (United States)

    Collins, Julie-Ann; Rudenski, Aram; Gibson, John; Howard, Luke; O'Driscoll, Ronan

    2015-09-01

    The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content), saturation (S O2 ) and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin-oxygen dissociation curve, a graphical representation of the relationship between oxygen satur-ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the S O2 in blood from patients with normal pH and S O2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (S pO2 ) is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (S aO2 ) as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable S pO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.

  19. In vivo detection of hemoglobin oxygen saturation and carboxyhemoglobin saturation with multiwavelength photoacoustic microscopy.

    Science.gov (United States)

    Chen, Zhongjiang; Yang, Sihua; Xing, Da

    2012-08-15

    A method for noninvasively detecting hemoglobin oxygen saturation (SO2) and carboxyhemoglobin saturation (SCO) in subcutaneous microvasculature with multiwavelength photoacoustic microscopy is presented. Blood samples mixed with different concentrations of carboxyhemoglobin were used to test the feasibility and accuracy of photoacoustic microscopy compared with the blood-gas analyzer. Moreover, fixed-point detection of SO2 and SCO in mouse ear was obtained, and the changes from normoxia to carbon monoxide hypoxia were dynamically monitored in vivo. Experimental results demonstrate that multiwavelength photoacoustic microscopy can detect SO2 and SCO, which has future potential clinical applications.

  20. Changes in retinal venular oxygen saturation predict activity of proliferative diabetic retinopathy 3 months after panretinal photocoagulation

    DEFF Research Database (Denmark)

    Torp, Thomas Lee; Kawasaki, Ryo; Wong, Tien Yin

    2018-01-01

    .4 to -1.4), focal: -4.5% (95% CI -12.1 to 3.2)). In a multiple logistic regression model, increment in global retinal venular oxygen saturation (OR 1.30 per 1%-point increment, p=0.017) and decrement in AV oxygen saturation difference (OR 0.72 per 1%-point increment, p=0.016) at 3M independently predicted...

  1. The relation between oxygen saturation level and retionopathy of prematurity

    Directory of Open Access Journals (Sweden)

    Mohammad Gharavi Fard

    2016-03-01

    Full Text Available Introduction: Oxygen therapy used for preterm infant disease might be associated with oxygen toxicity or oxidative stress. The exact oxygen concentration to control and maintain the arterial oxygen saturation balance is not certainly clear. We aimed to compare the efficacy of higher or lower oxygen saturations on the development of severe retinopathy of prematurity which is a major cause of blindness in preterm neonates. Methods: PubMed was searched for obtaining the relevant articles. A total of seven articles were included after studying the titles, abstracts, and the full text of retrieved articles at initial search. Inclusion criteria were all the English language human clinical randomized controlled trials with no time limitation, which studied the efficacy of low versus high oxygen saturation measured by pulse oximetry in preterm infants.Result: It can be suggested that lower limits of oxygen saturations have higher efficacy at postmesetural age of ≤28 weeks in preterm neonates. This relation has been demonstrated in five large clinical trials including three Boost trials, COT, and Support.Discussion: Applying higher concentrations of oxygen supplementations at mesentural age ≥32 weeks reduced the development of retinopathy of prematurity. Lower concentrations of oxygen saturation decreased the incidence and the development of retinopathy of prematurity in preterm neonates while applied soon after the birth.Conclusions: Targeting levels of oxygen saturation in the low or high range should be performed cautiously with attention to the postmesentural age in preterm infants at the time of starting the procedures.

  2. Relating oxygen partial pressure, saturation and content: the haemoglobin–oxygen dissociation curve

    Directory of Open Access Journals (Sweden)

    Julie-Ann Collins

    2015-09-01

    The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content, saturation (SO2 and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin–oxygen dissociation curve, a graphical representation of the relationship between oxygen satur­ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the SO2 in blood from patients with normal pH and SO2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (SpO2 is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (SaO2 as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable SpO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.

  3. Changes in retinal venular oxygen saturation predict activity of proliferative diabetic retinopathy 3 months after panretinal photocoagulation.

    Science.gov (United States)

    Torp, Thomas Lee; Kawasaki, Ryo; Wong, Tien Yin; Peto, Tunde; Grauslund, Jakob

    2018-03-01

    Proliferative diabetic retinopathy (PDR) is a severe blinding condition. We investigated whether retinal metabolism, measured by retinal oximetry, may predict PDR activity after panretinal laser photocoagulation (PRP). We performed a prospective, interventional, clinical study of patients with treatment-naive PDR. Wide-field fluorescein angiography (OPTOS, Optomap) and global and focal retinal oximetry (Oxymap T1) were performed at baseline (BL), and 3 months (3M) after PRP. Angiographic findings were used to divide patients according to progression or non-progression of PDR after PRP. We evaluated differences in global and focal retinal oxygen saturation between patients with and without progression of PDR after PRP treatment. We included 45 eyes of 37 patients (median age and duration of diabetes were 51.6 and 20 years). Eyes with progression of PDR developed a higher retinal venous oxygen saturation than eyes with non-progression at 3M (global: +5.9% (95% CI -1.5 to 12.9), focal: +5.4%, (95% CI -4.1 to 14.8)). Likewise, progression of PDR was associated with a lower arteriovenular (AV) oxygen difference between BL and 3M (global: -6.1%, (95% CI -13.4 to -1.4), focal: -4.5% (95% CI -12.1 to 3.2)). In a multiple logistic regression model, increment in global retinal venular oxygen saturation (OR 1.30 per 1%-point increment, p=0.017) and decrement in AV oxygen saturation difference (OR 0.72 per 1%-point increment, p=0.016) at 3M independently predicted progression of PDR. Development of higher retinal venular and lower AV global oxygen saturation independently predicts progression of PDR despite standard PRP and might be a potential non-invasive marker of angiogenic disease activity. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Validation of the Nonin 8600V Pulse Oximeter for heart rate and oxygen saturation measurements in rats.

    Science.gov (United States)

    Bernard, Susan L; An, Dowon; Glenny, Robb W

    2004-05-01

    This report validates the use and limitations of the Nonin Pulse Oximeter for measuring heart rate and oxygen saturation in rats. Eight anesthetized Sprague-Dawley rats were intubated and catheterized. Oxygen saturation was directly measured from arterial blood by using a Radiometer OSM3 Hemoximeter adjusted for rat blood as well as indirectly by using the Nonin Pulse Oximeter. Oxygen saturation was changed by varying the level of inhaled oxygen. Heart rate was measured in two ways: 1) by using the signal from the Nonin Pulse Oximeter and 2) by counting the pressure pulses from the transduced blood pressure. There was excellent agreement between heart rate values measured by the Nonin Pulse Oximeter and that measured by counting the pulses from the arterial blood pressure recording. The Nonin Pulse Oximeter underestimated oxygen saturations by about 3% to 5% compared to the Hemoximeter. Overall, the pulse oximeter reflected important trends in oxygen saturations, making it a useful tool for laboratory animal medicine.

  5. Renal vein oxygen saturation in renal artery stenosis

    DEFF Research Database (Denmark)

    Nielsen, K; Rehling, M; Henriksen, Jens Henrik Sahl

    1992-01-01

    Renal vein oxygen-saturation was measured in 56 patients with arterial hypertension and unilateral stenosis or occlusion of the renal artery. Oxygen-saturation in blood from the ischaemic kidney (84.4%, range 73-93%) was significantly higher than that from the 'normal' contralateral kidney (81...... than its blood flow. This is probably due to decreased filtration fraction and filtered sodium with subsequent reduction in absolute tubular re-absorption of sodium ions....

  6. Monitoring mixed venous oxygen saturation in patients with obstructive shock after massive pulmonary embolism.

    Science.gov (United States)

    Krivec, Bojan; Voga, Gorazd; Podbregar, Matej

    2004-05-31

    Patients with massive pulmonary embolism and obstructive shock usually require hemodynamic stabilization and thrombolysis. Little is known about the optimal and proper use of volume infusion and vasoactive drugs, or about the titration of thrombolytic agents in patients with relative contraindication for such treatment. The aim of the study was to find the most rapidly changing hemodynamic variable to monitor and optimize the treatment of patients with obstructive shock following massive pulmonary embolism. Ten consecutive patients hospitalized in the medical intensive care unit in the community General Hospital with obstructive shock following massive pulmonary embolism were included in the prospective observational study. Heart rate, systolic arterial pressure, central venous pressure, mean pulmonary-artery pressure, cardiac index, total pulmonary vascular-resistance index, mixed venous oxygen saturation, and urine output were measured on admission and at 1, 2, 3, 4, 8, 12, and 16 hours. Patients were treated with urokinase through the distal port of a pulmonary-artery catheter. At 1 hour, mixed venous oxygen saturation, systolic arterial pressure and cardiac index were higher than their admission values (31+/-10 vs. 49+/-12%, p<0.0001; 86+/-12 vs. 105+/-17 mmHg, p<0.01; 1.5+/-0.4 vs. 1.9+/-0.7 L/min/m2, p<0.05; respectively), whereas heart rate, central venous pressure, mean pulmonary-artery pressure and urine output remained unchanged. Total pulmonary vascular-resistance index was lower than at admission (29+/-10 vs. 21+/-12 mmHg/L/min/m2, p<0.05). The relative change of mixed venous oxygen saturation at hour 1 was higher than the relative changes of all other studied variables (p<0.05). Serum lactate on admission and at 12 hours correlated to mixed venous oxygen saturation (r=-0.855, p<0.001). In obstructive shock after massive pulmonary embolism, mixed venous oxygen saturation changes more rapidly than other standard hemodynamic variables.

  7. Diffuse reflectance spectroscopy for the measurement of tissue oxygen saturation

    International Nuclear Information System (INIS)

    Sircan-Kucuksayan, A; Canpolat, M; Uyuklu, M

    2015-01-01

    Tissue oxygen saturation (StO 2 ) is a useful parameter for medical applications. A spectroscopic method has been developed to detect pathologic tissues, due to a lack of normal blood circulation, by measuring StO 2 . In this study, human blood samples with different levels of oxygen saturation have been prepared and spectra were acquired using an optical fiber probe to investigate the correlation between the oxygen saturation levels and the spectra. A linear correlation between the oxygen saturation and ratio of the intensities (760 nm to 790 nm) of the spectra acquired from blood samples has been found. In a validation study, oxygen saturations of the blood samples were estimated from the spectroscopic measurements with an error of 2.9%. It has also been shown that the linear dependence between the ratio and the oxygen saturation of the blood samples was valid for the blood samples with different hematocrits. Spectra were acquired from the forearms of 30 healthy volunteers to estimate StO 2 prior to, at the beginning of, after 2 min, and at the release of total vascular occlusion. The average StO 2 of a forearm before and after the two minutes occlusion was significantly different. The results suggested that optical reflectance spectroscopy is a sensitive method to estimate the StO 2 levels of human tissue. The technique developed to measure StO 2 has potential to detect ischemia in real time. (paper)

  8. Rapid determination of oxygen saturation and vascularity for cancer detection.

    Directory of Open Access Journals (Sweden)

    Fangyao Hu

    Full Text Available A rapid heuristic ratiometric analysis for estimating tissue hemoglobin concentration and oxygen saturation from measured tissue diffuse reflectance spectra is presented. The analysis was validated in tissue-mimicking phantoms and applied to clinical measurements in head and neck, cervical and breast tissues. The analysis works in two steps. First, a linear equation that translates the ratio of the diffuse reflectance at 584 nm and 545 nm to estimate the tissue hemoglobin concentration using a Monte Carlo-based lookup table was developed. This equation is independent of tissue scattering and oxygen saturation. Second, the oxygen saturation was estimated using non-linear logistic equations that translate the ratio of the diffuse reflectance spectra at 539 nm to 545 nm into the tissue oxygen saturation. Correlations coefficients of 0.89 (0.86, 0.77 (0.71 and 0.69 (0.43 were obtained for the tissue hemoglobin concentration (oxygen saturation values extracted using the full spectral Monte Carlo and the ratiometric analysis, for clinical measurements in head and neck, breast and cervical tissues, respectively. The ratiometric analysis was more than 4000 times faster than the inverse Monte Carlo analysis for estimating tissue hemoglobin concentration and oxygen saturation in simulated phantom experiments. In addition, the discriminatory power of the two analyses was similar. These results show the potential of such empirical tools to rapidly estimate tissue hemoglobin in real-time spectral imaging applications.

  9. Oxygenation of saturated and unsaturated hydrocarbons with ...

    Indian Academy of Sciences (India)

    Unknown

    Oxygenation of saturated and unsaturated hydrocarbons with sodium periodate. 431. Table 1. Competitive oxygenation of tetralin and cyclooctene with sodium periodate catalyzed by different manga- .... Teacher Education University. My grateful thanks also extend to Dr D Mohajer for his useful sugges- tions. References. 1.

  10. Central venous oxygen saturation during hypovolaemic shock in humans

    DEFF Research Database (Denmark)

    Madsen, P; Iversen, H; Secher, N H

    1993-01-01

    We compared central venous oxygen saturation and central venous pressure (CVP) as indices of the effective blood volume during 50 degrees head-up tilt (anti-Trendelenburg's position) induced hypovolaemic shock in eight healthy subjects. Head-up tilt increased thoracic electrical impedance from 31...... (28-36) (median and range) to 34 (30-40) Ohm, mean arterial pressure (MAP) from 79 (70-88) to 86 (80-99) mmHg, heart rate (HR) from 67 (56-71) to 99 (78-119) beats min-1 (p ....05) but thereafter remained stable. In contrast, central venous oxygen saturation showed a linear decrease with time from 0.75 (0.69-0.78) at rest to 0.60 (0.49-0.67) (p measurement of central venous oxygen saturation...

  11. Effects of spinal immobilization at a 20° angle on cerebral oxygen saturations measured by INVOS™.

    Science.gov (United States)

    Aksel, Gökhan

    2018-01-01

    In this study, we aimed to investigate whether performing the immobilization at 20° instead of 0° changes cerebral oxygenation. 33 volunteers were put in a hard cervical collar and backboard at 0° and immobilized for 30min. The cerebral oxygen saturations of the volunteers were measured at 1, 5, and 30min after the start of the procedure (Group 1). The volunteers were asked to return the day after the Group 1 procedure but at the same time. Serial cerebral oxygen saturations were obtained at the same time intervals as in Group 1, but for Group 2, the backboard was set to 20°. When the cerebral oxygen saturations of the two groups were compared, there was a slight decrease when the backboard position was changed from 0° to 20°, but it was not statistically significant (P=0.220 and P=0.768, respectively). The results revealed that immobilizing the patients with a spinal backboard at 20° instead of 0° did not alter the cerebral oxygen saturations. Our study results revealed that spinal immobilization at 20°, which was a new suggestion for spinal immobilization following a report that this position reduced the decrease in pulmonary function secondary to spinal immobilization, did not alter the cerebral oxygenation, so this suggestion is safe at least from the standpoint of cerebral oxygenation. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. [Regional cerebral oxygen saturation as a marker of hemodynamic state following cardiac surgery].

    Science.gov (United States)

    García-Hernández, J A; Aldemira-Liz, A; Martínez-López, A I; Cayuela, A; Charlo-Molina, M T; Cano-Franco, J; Loscertales-Abril, M

    2013-10-01

    Regional cerebral oxygen saturation (rSO₂) is a measure of the general state of perfusion and oxygenation. We aim to analyze the relationship between this and various hemodynamic and respiratory parameters. Forty-three patients, operated on between October 2011 and July 2012, were included in this prospective observational descriptive study. The following parameters were measured: mean arterial pressure, both arterial and central venous oxygen saturation and partial pressures of oxygen and carbon dioxide, and lactate levels. From these parameters, the oxygenation index and the oxygen extraction ratio were calculated. These measurements were studied to evaluate whether rSO₂ correlated significantly with the other parameters. The average age and weight of the patients were 27.3 months and 9.2 kg, respectively. The rSO₂ correlated positively with both central venous oxygen saturation (r=0.73, P 0.4) between the rSO₂ and central venous oxygen saturation, and between the rSO₂ and oxygen extraction ratio. Regional cerebral oxygen saturation correlates well with hemodynamic parameters - mean arterial pressure, venous saturation, and the tissue oxygen extraction. However, it does not correlate with respiratory parameters. Copyright © 2012 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  13. Assessment of oxygen saturation in dental pulp of permanent teeth with periodontal disease.

    Science.gov (United States)

    Giovanella, Larissa Bergesch; Barletta, Fernando Branco; Felippe, Wilson Tadeu; Bruno, Kely Firmino; de Alencar, Ana Helena Gonçalves; Estrela, Carlos

    2014-12-01

    In individuals with periodontal disease, dental pulp status should be determined before a treatment plan is made. Pulse oximeters are promising diagnostic tools to evaluate pulp vascularization. This study used pulse oximetry to determine the level of oxygen saturation in dental pulp of intact permanent teeth with periodontal attachment loss (PAL) and gingival recession (GR) and to evaluate the correlation between periodontal disease and level of oxygen saturation in the pulp. This study included 67 anterior teeth of 35 patients; all teeth showed intact crowns, PAL, a periodontal pocket (PP), and GR. The teeth underwent periodontal examination, cold and electric pulp testing, and pulse oximetry measurements. The Pearson correlation coefficient and a linear regression coefficient were calculated to evaluate the degree of correlation between periodontal disease markers (PAL, PP, and GR) and the level of oxygen saturation in dental pulp. These tests also evaluated possible associations between oxygen saturation and cold and electric pulp testing. PAL, PP, and GR had negative correlations with oxygen saturation in dental pulp. Conversely, no statistically significant association was found between oxygen saturation in dental pulp and the response to electric sensibility testing. Oxygen saturation was lower in the pulp of permanent teeth with PAL, PP, and GR, indicating that periodontal disease correlates with the level of oxygen saturation in the pulp. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  14. Cerebral oxygen saturation and cardiac output during anaesthesia in sitting position for neurosurgical procedures: a prospective observational study.

    Science.gov (United States)

    Schramm, P; Tzanova, I; Hagen, F; Berres, M; Closhen, D; Pestel, G; Engelhard, K

    2016-10-01

    Neurosurgical operations in the dorsal cranium often require the patient to be positioned in a sitting position. This can be associated with decreased cardiac output and cerebral hypoperfusion, and possibly, inadequate cerebral oxygenation. In the present study, cerebral oxygen saturation was measured during neurosurgery in the sitting position and correlated with cardiac output. Perioperative cerebral oxygen saturation was measured continuously with two different monitors, INVOS ® and FORE-SIGHT ® . Cardiac output was measured at eight predefined time points using transoesophageal echocardiography. Forty patients were enrolled, but only 35 (20 female) were eventually operated on in the sitting position. At the first time point, the regional cerebral oxygen saturation measured with INVOS ® was 70 (sd 9)%; thereafter, it increased by 0.0187% min -1 (P<0.01). The cerebral tissue oxygen saturation measured with FORE-SIGHT ® started at 68 (sd 13)% and increased by 0.0142% min -1 (P<0.01). The mean arterial blood pressure did not change. Cardiac output was between 6.3 (sd 1.3) and 7.2 (1.8) litre min -1 at the predefined time points. Cardiac output, but not mean arterial blood pressure, showed a positive and significant correlation with cerebral oxygen saturation. During neurosurgery in the sitting position, the cerebral oxygen saturation slowly increases and, therefore, this position seems to be safe with regard to cerebral oxygen saturation. Cerebral oxygen saturation is stable because of constant CO and MAP, while the influence of CO on cerebral oxygen saturation seems to be more relevant. NCT01275898. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. [Study of blood oxygen saturation, heart rate changes and plateau reaction of the Antarctic Kunlun station investigation team in different plateau environments].

    Science.gov (United States)

    Zhao, Shun-yun; Wu, Xin-min; Guo, Ya-min; Zhang, Shu-shun; An, Yan-ming; Li, Bing; Wang, Hao

    2013-06-11

    To explore the blood oxygen saturation and heart rate changes of the Antarctic explorers. During August 2010 to April 2011, the changes in blood oxygen saturation, heart rate and plateau reaction of 16 Antarctic expedition team in different plateau environments (Tibetan plateau versus Antarctic plateau) were monitored with the noninvasive pulse oximeter MD300-C. The extent of acute mountain sickness was determined according to the Lake Louise Consensus acute mountain reaction symptom scores and judgment method. The changes of blood oxygen saturation, heart rate at different altitudes of 110, 3650, 4300 m (96.8% ± 1.2%,89.1% ± 1.2%, 86.1% ± 2.0%, (75.0 ± 5.4) times/min, (104.0 ± 4.3) times/min, (113.0 ± 5.2) times/min,F = 214.155, 240.088,both P rate at different altitudes of 2000, 2500, 3000, 3500 and 4087 m(91.9% ± 1.3%,90.5% ± 1.3%,87.6% ± 1.4%,85.0% ± 1.8%,81.5% ± 2.2%, (85.9 ± 3.2) times/min, (90.6 ± 2.8) times/min, (97.8 ± 4.1) times/min, (102.0 ± 3.4) times/min, (106.3 ± 3.9) times/min, F = 105.418, 90.174, both P rate were both correlated with the risk of altitude sickness (r = -0.446 and 0.565, both P rate of the Antarctic explorers. And with the increases of altitude, the risk of altitude sickness gradually increases.

  16. Development of an oxygen saturation measuring system by using near-infrared spectroscopy

    Science.gov (United States)

    Kono, K.; Nakamachi, E.; Morita, Y.

    2017-08-01

    Recently, the hypoxia imaging has been recognized as the advanced technique to detect cancers because of a strong relationship with the biological characterization of cancer. In previous studies, hypoxia imaging systems for endoscopic diagnosis have been developed. However, these imaging technologies using the visible light can observe only blood vessels in gastric mucous membrane. Therefore, they could not detect scirrhous gastric cancer which accounts for 10% of all gastric cancers and spreads rapidly into submucous membrane. To overcome this problem, we developed a measuring system of blood oxygen saturation in submucous membrane by using near-infrared (NIR) spectroscopy. NIR, which has high permeability for bio-tissues and high absorbency for hemoglobin, can image and observe blood vessels in submucous membrane. NIR system with LED lights and a CCD camera module was developed to image blood vessels. We measured blood oxygen saturation using the optical density ratio (ODR) of two wavelengths, based on Lambert-Beer law. To image blood vessel clearly and measure blood oxygen saturation accurately, we searched two optimum wavelengths by using a multilayer human gastric-like phantom which has same optical properties as human gastric one. By using Monte Carlo simulation of light propagation, we derived the relationship between the ODR and blood oxygen saturation and elucidated the influence of blood vessel depth on measuring blood oxygen saturation. The oxygen saturation measuring methodology was validated with experiments using our NIR system. Finally, it was confirmed that our system can detect oxygen saturation in various depth blood vessels accurately.

  17. Correlation between Oxygen Saturation and Hemoglobin and Hematokrit Levels in Tetralogy of Fallot Patients

    Directory of Open Access Journals (Sweden)

    Farhatul Inayah Adiputri

    2016-03-01

    Full Text Available Background: Hemoglobin and hematocrit levels increase in Tetralogy of Fallot (TOF but the oxygen saturation declines. Reduced hemoglobin in circulating blood as a parameter of cyanosis does not indicate rising hemoglobin due to the ‘not-working’ hemoglobins that affect the oxygen saturation. Increasing hematocrit is the result of secondary erythrocytosis caused by declining oxygen level in blood, which is related to the oxygen saturation. This study was conducted to find the correlation between oxygen saturation and hemoglobin and hematocrite levels in TOF patients. Methods: This study was undertaken at Dr. Hasan Sadikin General Hospital in the period of January 2011 to December 2012 using the cross-sectional analytic method with total sampling technique. Inclusion criteria were medical records of TOF patients diagnosed based on echocardiography that included data on oxygen saturation, hemoglobin, and hematocrite. Exclusion criteria was the history of red blood transfusion. Results: Thirty medical records of TOF patiens from Dr. Hasan Sadikin General Hospital Bandung were included in this study. Due to skewed data distribution, Spearman correlation test was used to analyze the data. There was a significant negative correlation between oxygen saturation and hematocrit level (r= -0.412; p=0.024 and insignificant correlation between oxygen saturation and hemoglobin (r=-0.329; p= 0.076. Conclusions: There is a weak negative correlation between oxygen saturation and hematocrite levels

  18. High or low oxygen saturation and severe retinopathy of prematurity: a meta-analysis.

    Science.gov (United States)

    Chen, Minghua L; Guo, Lei; Smith, Lois E H; Dammann, Christiane E L; Dammann, Olaf

    2010-06-01

    Low oxygen saturation appears to decrease the risk of severe retinopathy of prematurity (ROP) in preterm newborns when administered during the first few weeks after birth. High oxygen saturation seems to reduce the risk at later postmenstrual ages (PMAs). However, previous clinical studies are not conclusive individually. To perform a systematic review and meta-analysis to report the association between severe ROP incidence of premature infants with high or low target oxygen saturation measured by pulse oximetry. Studies were identified through PubMed and Embase literature searches through May 2009 by using the terms "retinopathy of prematurity and oxygen" or "retinopathy of prematurity and oxygen therapy." We selected 10 publications addressing the association between severe ROP and target oxygen saturation measured by pulse oximetry. Using a random-effects model we calculated the summary-effect estimate. We visually inspected funnel plots to examine possible publication bias. Low oxygen saturation (70%-96%) in the first several postnatal weeks was associated with a reduced risk of severe ROP (risk ratio [RR]: 0.48 [95% confidence interval (CI): 0.31-0.75]). High oxygen saturation (94%-99%) at > or = 32 weeks' PMA was associated with a decreased risk for progression to severe ROP (RR: 0.54 [95% CI: 0.35-0.82]). Among preterm infants with a gestational age of large randomized clinical trial with long-term developmental follow-up is warranted to confirm this meta-analytic result.

  19. Short-term Effects of Air Pollution on Oxygen Saturation in a Cohort of Senior Adults in Steubenville, OH

    Science.gov (United States)

    Luttmann-Gibson, Heike; Sarnat, Stefanie Ebelt; Suh, Helen H.; Coull, Brent A.; Schwartz, Joel; Zanobetti, Antonella; Gold, Diane R.

    2014-01-01

    Objective We examine whether ambient air pollution is associated with oxygen saturation in 32 elderly subjects in Steubenville. Methods We used linear mixed models to examine the effects of fine particles (PM2.5), sulfate (SO42-), elemental carbon (EC), and gases on median oxygen saturation. Results An interquartile range (IQR) increase of 13.4 μg/m3 in PM2.5 on the previous day was associated with a decrease of -0.18% (95% CI: -0.31 to -0.06), and a 5.1 μg/m3 IQR increase in SO42- on the previous day was associated with a decrease of -0.16% (95% CI: -0.27 to -0.04) in oxygen saturation during the initial 5-min rest period of the protocol. Conclusions Increased exposure to air pollution, including the non-traffic pollutant SO42- from industrial sources, led to changes in oxygen saturation that may reflect particle-induced pulmonary inflammatory or vascular responses. PMID:24451609

  20. Short-term effects of air pollution on oxygen saturation in a cohort of senior adults in Steubenville, Ohio.

    Science.gov (United States)

    Luttmann-Gibson, Heike; Sarnat, Stefanie Ebelt; Suh, Helen H; Coull, Brent A; Schwartz, Joel; Zanobetti, Antonella; Gold, Diane R

    2014-02-01

    We examine whether ambient air pollution is associated with oxygen saturation in 32 elderly subjects in Steubenville, Ohio. We used linear mixed models to examine the effects of fine particulate matter less than 2.5 μm (PM(2.5)), sulfate (SO(4)(-2)), elemental carbon, and gases on median oxygen saturation. An interquartile range increase of 13.4 μg/m in PM(2.5) on the previous day was associated with a decrease of -0.18% (95% confidence interval: -0.31 to -0.06) and a 5.1 μg/m(3) interquartile range increase in SO(4)(-2) on the previous day was associated with a decrease of -0.16% (95% confidence interval: -0.27 to -0.04) in oxygen saturation during the initial 5-minute rest period of the protocol. Increased exposure to air pollution, including the nontraffic pollutant SO(4)(-2) from industrial sources, led to changes in oxygen saturation that may reflect particle-induced pulmonary inflammatory or vascular responses.

  1. Evaluation of Nd:YAG laser on partial oxygen saturation of pulpal blood in anterior hypersensitive teeth.

    Science.gov (United States)

    Birang, Reza; Kaviani, Naser; Mohammadpour, Mehdi; Abed, Ahmad Moghareh; Gutknecht, Norbert; Mir, Maziar

    2008-07-01

    Dentine hypersensitivity has of long been known to be a common clinical problem in dental practices. Lasers have recently come to play a prominent role in the treatment of this disorder. They might, however, cause dental pulp damage. This study was conducted to evaluate the effect of Nd:yttrium-aluminum-garnet (YAG) laser on partial oxygen saturation of pulpal blood in sensitive anterior teeth. In this clinical trial, 65 hypersensitive teeth were selected and randomly allocated to two groups. The study group involved Nd:YAG laser treatment, while no treatment was employed for the control group. Using a pulse oximetry system, evaluations were preformed of the partial oxygen saturation in the pulpal blood before, immediately after, 1 week after, and 1 month after the treatment. The results were analyzed using the SPSS software and repeated-measures analysis of variance and paired-samples t tests. The mean partial oxygen saturation of the blood was found to be 85.4% in the study group, which was not significantly different from that of the control group. No significant differences were observed in the control group between the means obtained from pretreatment and post-treatment intervals (P > 0.05). The Post-treatment partial oxygen saturation mean rose to 89.3% (P = 0.001) and remained constant throughout the following week after it. However, no significant differences were found between the pretreatment partial oxygen saturation mean and the same measurement 1 month after treatment (P = 0.702). Nd:YAG laser therapy for dentine desensitization of anterior teeth caused no persistent changes in the partial oxygen saturation of pulpal blood. It may, therefore, be concluded that the diffusion of heat induced by the Nd:YAG laser into the pulp within the limit of the desensitization parameters cause no irreversible damages in the dental pulp.

  2. Oxygen general saturation after bronchography under general ...

    African Journals Online (AJOL)

    Thirty-six patients undergoing bronchography or bronchoscopy under general anaesthesia were continuously monitored by pulse oximetry for 5 hours after these procedures. Significant falls in oxygen saturation were observed in the first hour and were of most clinical relevance in patients with preexisting pulmonary ...

  3. Validation of NIRS in measuring tissue hemoglobin concentration and oxygen saturation on ex vivo and isolated limb models

    Science.gov (United States)

    Xu, Xiaorong; Zhu, Wen; Padival, Vikram; Xia, Mengna; Cheng, Xuefeng; Bush, Robin; Christenson, Linda; Chan, Tim; Doherty, Tim; Iatridis, Angelo

    2003-07-01

    Photonify"s tissue spectrometer uses Near-Infrared Spectroscopy for real-time, noninvasive measurement of hemoglobin concentration and oxygen saturation [SO2] of biological tissues. The technology was validated by a series of ex vivo and animal studies. In the ex vivo experiment, a close loop blood circulation system was built, precisely controlling the oxygen saturation and the hemoglobin concentration of a liquid phantom. Photonify"s tissue spectrometer was placed on the surface of the liquid phantom for real time measurement and compared with a gas analyzer, considered the gold standard to measure oxygen saturation and hemoglobin concentration. In the animal experiment, the right hind limb of each dog accepted onto the study was surgically removed. The limb was kept viable by connecting the femoral vein and artery to a blood-primed extracorporeal circuit. Different concentrations of hemoglobin were obtained by adding designated amount of saline solution into the perfusion circuit. Photonify"s tissue spectrometers measured oxygen saturation and hemoglobin concentration at various locations on the limb and compared with gas analyzer results. The test results demonstrated that Photonify"s tissue spectrometers were able to detect the relative changes in tissue oxygen saturation and hemoglobin concentration with a high linear correlation compared to the gas analyzer

  4. Systematic instrumental errors between oxygen saturation analysers in fetal blood during deep hypoxemia.

    Science.gov (United States)

    Porath, M; Sinha, P; Dudenhausen, J W; Luttkus, A K

    2001-05-01

    During a study of artificially produced deep hypoxemia in fetal cord blood, systematic errors of three different oxygen saturation analysers were evaluated against a reference CO oximeter. The oxygen tensions (PO2) of 83 pre-heparinized fetal blood samples from umbilical veins were reduced by tonometry to 1.3 kPa (10 mm Hg) and 2.7 kPa (20 mm Hg). The oxygen saturation (SO2) was determined (n=1328) on a reference CO oximeter (ABL625, Radiometer Copenhagen) and on three tested instruments (two CO oximeters: Chiron865, Bayer Diagnostics; ABL700, Radiometer Copenhagen, and a portable blood gas analyser, i-STAT, Abbott). The CO oximeters measure the oxyhemoglobin and the reduced hemoglobin fractions by absorption spectrophotometry. The i-STAT system calculates the oxygen saturation from the measured pH, PO2, and PCO2. The measurements were performed in duplicate. Statistical evaluation focused on the differences between duplicate measurements and on systematic instrumental errors in oxygen saturation analysis compared to the reference CO oximeter. After tonometry, the median saturation dropped to 32.9% at a PO2=2.7 kPa (20 mm Hg), defined as saturation range 1, and to 10% SO2 at a PO2=1.3 kPa (10 mm Hg), defined as range 2. With decreasing SO2, all devices showed an increased difference between duplicate measurements. ABL625 and ABL700 showed the closest agreement between instruments (0.25% SO2 bias at saturation range 1 and -0.33% SO2 bias at saturation range 2). Chiron865 indicated higher saturation values than ABL 625 (3.07% SO2 bias at saturation range 1 and 2.28% SO2 bias at saturation range 2). Calculated saturation values (i-STAT) were more than 30% lower than the measured values of ABL625. The disagreement among CO oximeters was small but increasing under deep hypoxemia. Calculation found unacceptably low saturation.

  5. [Sedation with intravenous midazolam during upper gastrointestinal endoscopy--changes in hemodynamics, oxygen saturation and memory].

    Science.gov (United States)

    Mizuno, Ju; Matsuki, Michiko; Gouda, Yoshinori; Nishiyama, Tomoki; Hanaoka, Kazuo

    2003-09-01

    Cardiorespiratory adverse effects are often observed in patients undergoing upper gastrointestinal endoscopy with sedation. In this study, we examined hemodynamics, oxygen saturation and memory during upper gastrointestinal endoscopy under sedation with intravenous midazolam. Eight healthy outpatients without any obvious complications received intravenous midazolam 5 mg for sedation for upper gastrointestinal endoscopy. Blood pressure, heart rate and percutaneous arterial oxygen saturation (SpO2) were measured before, during and after endoscopy. After the arousal by intravenous flumazenil, we inquired the patients about the level of memory during the endoscopy. Blood pressure decreased significantly two minutes after midazolam administration, but increased significantly after the insertion of an endoscope which was not different from the control value. Heart rate increased significantly one and three minutes after the insertion of the endoscope. SpO2 decreased significantly after midazolam administration and stayed at around 95%. No patients remembered the procedure. Sedation with intravenous midazolam during upper gastrointestinal endoscopy is useful to control the cardiovascular responses, and to obtain amnesia. However, a decrease in SpO2 should be watched carefully.

  6. The influence of systemic hemodynamics and oxygen transport on cerebral oxygen saturation in neonates after the Norwood procedure.

    Science.gov (United States)

    Li, Jia; Zhang, Gencheng; Holtby, Helen; Guerguerian, Anne-Marie; Cai, Sally; Humpl, Tilman; Caldarone, Christopher A; Redington, Andrew N; Van Arsdell, Glen S

    2008-01-01

    Ischemic brain injury is an important morbidity in neonates after the Norwood procedure. Its relationship to systemic hemodynamic oxygen transport is poorly understood. Sixteen neonates undergoing the Norwood procedure were studied. Continuous cerebral oxygen saturation was measured by near-infrared spectroscopy. Continuous oxygen consumption was measured by respiratory mass spectrometry. Pulmonary and systemic blood flow, systemic vascular resistance, oxygen delivery, and oxygen extraction ratio were derived with measurements of arterial, and superior vena cava and pulmonary venous gases and pressures at 2- to 4-hour intervals during the first 72 hours in the intensive care unit. Mean cerebral oxygen saturation was 66% +/- 12% before the operation, reduced to 51% +/- 13% on arrival in the intensive care unit, and remained low during the first 8 hours; it increased to 56% +/- 9% at 72 hours, still significantly lower than the preoperative level (P blood flow and oxygen delivery (P blood flow (P = .001) and hemoglobin (P = .02) and negatively correlated with systemic vascular resistance (P = .003). It was not correlated with oxygen consumption (P > .05). Cerebral oxygen saturation decreased significantly in neonates during the early postoperative period after the Norwood procedure and was significantly influenced by systemic hemodynamic and metabolic events. As such, hemodynamic interventions to modify systemic oxygen transport may provide further opportunities to reduce the risk of cerebral ischemia and improve neurodevelopmental outcomes.

  7. An in vivo evaluation of the change in the pulpal oxygen saturation after administration of preoperative anxiolytics and local anesthesia

    Directory of Open Access Journals (Sweden)

    Krishna P. Shetty

    2016-03-01

    Full Text Available Background. Given the influence of systemic blood pressure on pulpal blood flow, anxiolytics prescribed may alter the pulpal blood flow along with the local anesthetic solution containing a vasoconstrictor. This study evaluated the impact of preoperative anxiolytics and vasoconstrictors in local anesthetic agents on pulpal oxygen saturation. Methods. Thirty anxious young healthy individuals with a mean age of 24 years were randomly selected using the Corah’s Dental Anxiety Scale (DAS. After checking the vital signs the initial pulpal oxygen saturation (initial SpO2 was measured using a pulse oximeter. Oral midzolam was administered at a dose of 7.5 mg. After 30 min, the vital signs were monitored and the pulpal oxygen saturation (anxiolytic SpO2 was measured. A total of 1.5 mL of 2% lidocaine with 1:200000 epinephrine was administered as buccal infiltration anesthesia and 10 min the final pulpal oxygen saturation (L.A SpO2 was measured. Results. The mean initial (SpO2 was 96.37% which significantly decreased to 90.76% (SpO2 after the administration of the anxiolytic agent. This drop was later accentuated to 85.17% (SpO2 after administration of local anesthetic solution. Statistical significance was set at P<0.0001. Conclusion. High concentrations of irritants may permeate dentin due to a considerable decrease in the pulpal blood flow from crown or cavity preparation. Therefore, maintaining optimal blood flow during restorative procedures may prevent pulpal injury.

  8. Oxygen Saturation in the Dental Pulp of Maxillary Premolars in Different Age Groups - Part 1.

    Science.gov (United States)

    Estrela, Carlos; Serpa, Giuliano C; Alencar, Ana Helena G; Bruno, Kely F; Barletta, Fernando B; Felippe, Wilson T; Estrela, Cyntia R A; Souza, João B

    2017-01-01

    The aim of this study was to determine oxygen saturation levels in the dental pulp of maxillary premolars in different age groups. A total of 120 human maxillary premolars with normal dental pulps were selected covering the following age groups: 20-24, 25-29, 30-34, 35-39 and 40-44 years (n=24 each group). Oxygen saturation was assessed using pulse oximetry. Analysis of variance was used to assess differences in oxygen saturation levels and Tukey's test was used to identify the age groups that differed from each other. Significance was set at 0.05. Mean oxygen saturation of 120 premolars was 86.20% considering all age groups. Significantly reduced levels were found in the oldest group compared to the other groups: 40 to 44 years - 80.00% vs. 89.71, 87.67, 88.71, and 84.80% for age groups 20-24, 25-29, 30-34, 35-39 years, respectively. The mean oxygen saturation levels were similar between 20 and 39 years of age (86.20%) in the whole sample, but reduced significantly in the 40-44-year age group, suggesting that older patients present lower oxygen saturation results even in the absence of pulp tissue injury.

  9. Near-infrared spectroscopy during stagnant ischemia estimates central venous oxygen saturation and mixed venous oxygen saturation discrepancy in patients with severe left heart failure and additional sepsis/septic shock

    OpenAIRE

    Mo?ina, Hugo; Podbregar, Matej

    2010-01-01

    Introduction Discrepancies of 5-24% between superior vena cava oxygen saturation (ScvO2) and mixed venous oxygen saturation (SvO2) have been reported in patients with severe heart failure. Thenar muscle tissue oxygenation (StO2) measured with near-infrared spectroscopy (NIRS) during arterial occlusion testing decreases slower in sepsis/septic shock patients (lower StO2 deoxygenation rate). The StO2 deoxygenation rate is influenced by dobutamine. The aim of this study was to determine the rela...

  10. Prediction of saturation using the carbon/oxygen log

    Energy Technology Data Exchange (ETDEWEB)

    Horner, S.C.; Sanyal, S.K.

    1984-09-01

    This project investigates the nature of Dresser-Atlas Carbon/Oxygen Log gamma ray spectra. It presents an attempt to improve the signal-to-noise ratio of the C/O and Si/Ca parameters used by Dresser-Atlas to determine oil saturation. Two techniques were developed to subtract the Compton background from the spectral data. Neither technique significantly improves the accuracy of the cased-hole prediction of oil saturation. However, it has been shown that it is possible to develop a satisfactory correlation for oil saturation on a well-by-well basis. This correlation can then be used to generate oil-in-place from the C/O and Si/Ca ratios. 17 references.

  11. The effect of tourniquet deflation on hemodynamics and regional cerebral oxygen saturation in aged patients undergoing total knee replacement surgery

    OpenAIRE

    Song, Inkyung; Kim, Dong Yeon; Kim, Youn Jin

    2012-01-01

    Background Inflation and deflation of a pneumatic tourniquet used in total knee replacement surgery induces various changes in patient's hemodynamic and metabolic status, which may result in serious complications, especially in aged patients. Near-infrared spectroscopy (NIRS) is a monitoring device designed to estimate the regional cerebral oxygen saturation. We evaluated the effect of tourniquet deflation on hemodynamics and regional cerebral oxygen saturation in aged patients undergoing tot...

  12. Improvement in retinal venous oxygen saturation after panretinal photocoagulation is predictive of progression of proliferative diabetic retinopathy

    DEFF Research Database (Denmark)

    Torp, Thomas Lee; Kawasaki, Ryo; Wong, Tien Yin

    blood pressure was 152/84mmHg. Retinal arterial and venous saturation was 96.7% and 67.4%, respectively. Patients in Group 1 and 2 did not differ in baseline retinal arterial and venous oxygen saturation, number of laser spots delivered, total laser energy delivered, or change in retinal arterial oxygen...... patients with diagnosed PDR were included. We performed wide-field fluorescein angiography (WFA) (Optomap; Optos PLC., Dunfermline, Scotland, UK) and retinal oximetry (Oxymap model T1; Oxymap, software version 2.4.2, Reykjavik, Iceland) at baseline and three months after PRP by a navigated laser (NAVILAS...

  13. Compliance in oxygen saturation targeting in preterm infants : a systematic review

    NARCIS (Netherlands)

    van Zanten, Henriëtte A; Tan, Ratna N G B; van den Hoogen, Agnes; Lopriore, Enrico; te Pas, Arjan B

    2015-01-01

    UNLABELLED: During oxygen therapy in preterm infants, targeting oxygen saturation is important for avoiding hypoxaemia and hyperoxaemia, but this can be very difficult and challenging for neonatal nurses. We systematically reviewed the qualitative and quantitative studies investigating the

  14. Oxygen diffusion-concentration in phospholipidic model membranes. An ESR-saturation study

    International Nuclear Information System (INIS)

    Vachon, A.; Lecomte, C.; Berleur, F.

    1986-04-01

    Fully hydrated liposomes of dipalmitoyl-phosphatidylcholine were labelled with 5 (or 7, 10, 12, 16)-doxyl stearic acid at pH 6 and 8, and studied by the continuous wave ESR-saturation technique. The ESR spectral magnitude depends on the hyperfrequency power P and on both T 1 and T 2 relaxation times. Saturation, i.e. the non linearity of the spectral magnitude plotted versus √P can be quantified by a P1/2 parameter (power at which the signal is half as great as it would be without saturation). If we assume T 2 weakly modified by spin exchange between paramagnetic spin probe and oxygen in triplet state, P1/2 is inversely proportional to T 1 , and becomes a sensitive parameter to appreciate the oxygen transport (oxygen diffusion-concentration product) inside the bilayers. According to the DPPC bilayer phase transition diagrams, P1/2 (oxygen diffusion-concentration) is related to the thermodynamic state of the membrane. This technique provides further informations on a particular property of a radioprotective agent, cysteamine, which seems to inhibit spin-triplet exchange and hence maximizes T 1 (minimizes P1/2). Since radioprotective agents are known to act by scavenging radiation-induced free radicals and by inhibiting oxygen-dependent free radical processes, such a result may contribute to elucidate radioprotecting mechanisms

  15. Neuroprotection of hyperbaric oxygen therapy in sub-acute traumatic brain injury: not by immediately improving cerebral oxygen saturation and oxygen partial pressure.

    Science.gov (United States)

    Zhou, Bao-Chun; Liu, Li-Jun; Liu, Bing

    2016-09-01

    Although hyperbaric oxygen (HBO) therapy can promote the recovery of neural function in patients who have suffered traumatic brain injury (TBI), the underlying mechanism is unclear. We hypothesized that hyperbaric oxygen treatment plays a neuroprotective role in TBI by increasing regional transcranial oxygen saturation (rSO 2 ) and oxygen partial pressure (PaO 2 ). To test this idea, we compared two groups: a control group with 20 healthy people and a treatment group with 40 TBI patients. The 40 patients were given 100% oxygen of HBO for 90 minutes. Changes in rSO 2 were measured. The controls were also examined for rSO 2 and PaO 2 , but received no treatment. rSO 2 levels in the patients did not differ significantly after treatment, but levels before and after treatment were significantly lower than those in the control group. PaO 2 levels were significantly decreased after the 30-minute HBO treatment. Our findings suggest that there is a disorder of oxygen metabolism in patients with sub-acute TBI. HBO does not immediately affect cerebral oxygen metabolism, and the underlying mechanism still needs to be studied in depth.

  16. Retinal oxygen saturation in relation to retinal thickness in diabetic macular edema

    DEFF Research Database (Denmark)

    Blindbæk, Søren Leer; Peto, Tunde; Grauslund, Jakob

    to retinal thickness in patients with diabetic macular edema (DME). Methods: We included 18 patients with DME that all had central retinal thickness (CRT) >300 µm and were free of active proliferative diabetic retinopathy. Optical coherence tomography (Topcon 3D OCT-2000 spectral domain OCT) was used...... for paracentral edema, the oxygen saturation in the upper and lower temporal arcade branches were compared to the corresponding upper and lower subfield thickness. Spearman’s rank was used to calculate correlation coefficients between CRT and retinal oximetry. Results: Median age and duration of diabetes was 59....... 92.3%, p=0.52). We found no correlation between CRT and retinal oxygen saturation, even when accounting for paracentral edema (p>0.05). Furthermore, there was no difference in retinal oxygen saturation between the macular hemisphere that was more or less affected by DME (p>0.05). Conclusion: Patients...

  17. Optimization measurement of muscle oxygen saturation under isometric studies using FNIRS

    Science.gov (United States)

    Halim, A. A. A.; Laili, M. H.; Salikin, M. S.; Rusop, M.

    2018-05-01

    Development of functional near infrared spectroscopy (fNIRS) technologies has advanced quantification signal using multiple wavelength and detector to investigate hemodynamic response in human muscle. These non-invasive technologies have been widely used to solve the propagation of light inside the tissues including the absorption, scattering coefficient and to quantify the oxygenation level of haemoglobin and myoglobin in human muscle. The goal of this paper is to optimize the measurement of muscle oxygen saturation during isometric exercise using functional near infrared spectroscopy (fNIRS). The experiment was carried out on 15 sedentary healthy male volunteers. All volunteers are required to perform an isometric exercise at three assessment of muscular fatigue's level on flexor digitalis (FDS) muscle in the human forearm using fNIRS. The slopes of the signals have been highlighted to evaluate the muscle oxygen saturation of regional muscle fatigue. As a result, oxygen saturation slope from 10% exercise showed steeper than the first assessment at 30%-50% of fatigues level. The hemodynamic signal response showed significant value (p=0.04) at all three assessment of muscular fatigue's level which produce a p-value (p<0.05) measured by fNIRS. Thus, this highlighted parameter could be used to estimate fatigue's level of human and could open other possibilities to study muscle performance diagnosis.

  18. The Effect of Non-nutritive Sucking on Transcutaneous Oxygen Saturation in Neonates under the Nasal Continuous Positive Airway Pressure (CPAP

    Directory of Open Access Journals (Sweden)

    Mousa Ahmadpour-kacho

    2017-03-01

    Full Text Available BackgroundSeveral beneficial effects of non-nutritive sucking in infants, including the physiological stability, relaxation, better transition from tube feeding to oral feeding have been reported. But its effect on oxygen saturation in neonates under the Nasal Continuous Positive Airway Pressure (NCPAPو (is not so clear. This study aimed to investigate the effects of non-nutritive sucking on transcutaneous oxygen saturation levels of neonates treated with NCPAP.Materials and MethodsThis quasi-experimental study was done on 25 preterm neonates, hospitalized with a diagnosis of respiratory distress, required NCPAP, in the neonatal intensive care unit (NICU at the Ayatollah Rouhani Hospital and Babol Clinic, North of Iran. Non-nutritive sucking was elicited by a standard pacifier appropriate to their age one hour a day, and the mean oxygen saturation was measured before and after intervention by cardiopulmonary monitoring (Saadat Co., Iran. Data analyzed using SPSS-18.0 software.ResultsIn the 25 cases studied, the mean oxygen saturation values ​​before performing non-nutritive sucking was 96.31±2.88%, which was changed to 98.35±1.6% after intervention, and this increase was statistically significant (P = 0.004.Results showed that the gender, birth weight and gestational age of neonates had no effect on mean Blood oxygen saturation (SpO2level.ConclusionAccording to the results, using the non-nutritive sucking in premature neonates under the NCPAP, can improve oxygenation.

  19. Nocturnal oxygen saturation profiles of healthy term infants.

    Science.gov (United States)

    Terrill, Philip Ian; Dakin, Carolyn; Hughes, Ian; Yuill, Maggie; Parsley, Chloe

    2015-01-01

    Pulse oximetry is used extensively in hospital and home settings to measure arterial oxygen saturation (SpO2). Interpretation of the trend and range of SpO2 values observed in infants is currently limited by a lack of reference ranges using current devices, and may be augmented by development of cumulative frequency (CF) reference-curves. This study aims to provide reference oxygen saturation values from a prospective longitudinal cohort of healthy infants. Prospective longitudinal cohort study. Sleep-laboratory. 34 healthy term infants were enrolled, and studied at 2 weeks, 3, 6, 12 and 24 months of age (N=30, 25, 27, 26, 20, respectively). Full overnight polysomnography, including 2 s averaging pulse oximetry (Masimo Radical). Summary SpO2 statistics (mean, median, 5th and 10th percentiles) and SpO2 CF plots were calculated for each recording. CF reference-curves were then generated for each study age. Analyses were repeated with sleep-state stratifications and inclusion of manual artefact removal. Median nocturnal SpO2 values ranged between 98% and 99% over the first 2 years of life and the CF reference-curves shift right by 1% between 2 weeks and 3 months. CF reference-curves did not change with manual artefact removal during sleep and did not vary between rapid eye movement (REM) and non-REM sleep. Manual artefact removal did significantly change summary statistics and CF reference-curves during wake. SpO2 CF curves provide an intuitive visual tool for evaluating whether an individual's nocturnal SpO2 distribution falls within the range of healthy age-matched infants, thereby complementing summary statistics in the interpretation of extended oximetry recordings in infants. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. In vivo integrated photoacoustic and confocal microscopy of hemoglobin oxygen saturation and oxygen partial pressure.

    Science.gov (United States)

    Wang, Yu; Hu, Song; Maslov, Konstantin; Zhang, Yu; Xia, Younan; Wang, Lihong V

    2011-04-01

    We developed dual-modality microscope integrating photoacoustic microscopy (PAM) and fluorescence confocal microscopy (FCM) to noninvasively image hemoglobin oxygen saturation (sO₂) and oxygen partial pressure (pO₂) in vivo in single blood vessels with high spatial resolution. While PAM measures sO₂ by imaging hemoglobin optical absorption at two wavelengths, FCM quantifies pO₂ using phosphorescence quenching. The variations of sO₂ and pO₂ values in multiple orders of vessel branches under hyperoxic (100% oxygen) and normoxic (21% oxygen) conditions correlate well with the oxygen-hemoglobin dissociation curve. In addition, the total concentration of hemoglobin is imaged by PAM at an isosbestic wavelength.

  1. Calibration-free technique for the measurement of oxygen saturation changes in muscles of marine mammals and its proof of concept

    Science.gov (United States)

    Ortega-Martinez, Antonio; Goenka, Chhavi; Booker, Marloes; Grange, Robert M. H.; Hindle, Allyson G.; Franco, Walfre

    2018-02-01

    Marine mammals possess impressive breath-holding capabilities made possible by physiological adjustments during dives. Studying marine mammals in their natural environment unravels vital information about these physiological adjustments particularly when we can monitor altered dive behavior in response to stressful situations such as human-induced oceanic disturbances, presence of predators and altered prey distributions. An important indicator of physiological status during submergence is the change in oxygen saturation in the muscles and blood of these mammals. In this work, we aim to investigate oxygen storage and consumption in the muscles of free-diving elephant seals when exposed to disturbances such as sonar or predator sounds while they are at sea. Optical oxygen sensors are a mature technology with multiple medical applications that provide a way to measure oxygenation changes in biological tissues in a minimally invasive manner. While these sensors are well calibrated and readily available for humans, they are still inadequate for marine mammals primarily due to a very small number of test candidates and therefore little data is available for validation and calibration. We propose a probe geometry and associated mathematical model for measuring muscle oxygenation in seals based on near infrared diffuse transport with no need for calibration. A prototype based on this concept has been designed and tested on humans and rats. We use the test results to discuss the advantages and limitations of the approach. We also detail the constraints on size, sensor location, electronics, light source properties and detector characteristics posed by the unique biology of seals.

  2. Macular Retinal Vessel Oxygen Saturation Elevation in Chinese Central Serous Chorioretinopathy

    Directory of Open Access Journals (Sweden)

    Cheng Li

    2017-01-01

    Full Text Available Purpose. To evaluate the retinal vessel oxygen saturation in central serous chorioretinopathy (CSC cases among the Chinese. Methods. Relative oxygen saturation of retinal blood vessels was measured in 33 Chinese patients with single-eye CSC using the Oxymap T1 retinal oximeter. The contralateral eyes were the control. The mean saturation of the retinal arteriole (AS and venule (VS, arteriovenous difference (AVS, and arteriole and venule diameters (AD, VD was analyzed in the optic disc area and macular region. Results. In the optic disc area, the inferotemporal quadrant (TI AS (93.2 ± 10.2% and inferonasal quadrant (NI VS (61.3 ± 7.3% were higher in the affected eyes than in the contralateral eyes (88.7 ± 7.7% and 56.9 ± 6.5% and AVS in NI (36.7 ± 10.4% decreased compared to the contralateral eyes (41.5 ± 11.2%. The VD in TI was expanded (19.9 ± 2.5 pixels versus 18.1 ± 3.4 pixels. Around the macular region, AS was 93.6 ± 7.6%, higher than in the contralateral eyes (89.5 ± 6.3%. No other significant changes were found. Conclusions. AS increased in the TI, and VS decreased in the NI in the eyes with CSC. In addition, AS also increased around the macular region, suggesting that these are contributors to CSC pathophysiology.

  3. Sodium addition and/or oxygen saturation of iohexol during normal and reduced perfusion pressure

    International Nuclear Information System (INIS)

    Baath, L.

    1990-01-01

    The influence on contractile force (CF) and the propensity for ventricular fibrillation (VF) from infusing the non-ionic contrast medium iohexol during normal (75 cm H 2 O) and reduced perfusion pressure (35 cm H 2 O) were investigated in the isolated rabbit heart. Both during normal and reduced perfusion pressure iohexol (150 mg I/ml) with oxygen saturation caused a smaller reduction of CF than iohexol without oxygen. During reduced pressure iohexol with sodium addition (28 mM NaCl) caused less depression of CF than iohexol without sodium. The combination of sodium addition and oxygen saturation had the least influence on CF. Iohexol (350 mg I/ml) without sodium had a similar fibrillatory propensity during both normal and reduced pressure. Enriching iohexol with 28 mM NaCl decreased the risk of VF. The decrease was similar during both normal and reduced pressure. The risk of VF from oxygen saturation of iohexol (350 mg I/ml, without sodium) was similar during both normal and reduced pressure. It is concluded that a small addition of sodium and/or oxygen saturation of a non-ionic monomeric contrast medium have beneficial effects on the heart both during normal perfusion pressure and during ischemia. (orig.)

  4. The effect of tourniquet deflation on hemodynamics and regional cerebral oxygen saturation in aged patients undergoing total knee replacement surgery.

    Science.gov (United States)

    Song, Inkyung; Kim, Dong Yeon; Kim, Youn Jin

    2012-11-01

    Inflation and deflation of a pneumatic tourniquet used in total knee replacement surgery induces various changes in patient's hemodynamic and metabolic status, which may result in serious complications, especially in aged patients. Near-infrared spectroscopy (NIRS) is a monitoring device designed to estimate the regional cerebral oxygen saturation. We evaluated the effect of tourniquet deflation on hemodynamics and regional cerebral oxygen saturation in aged patients undergoing total knee replacement surgery, using NIRS. Twenty-eight American Society of Anesthesiologists physical status I or II patients, over the age of sixty-five years undergoing total knee replacement surgery, were included. Under general anesthesia, the mean arterial pressure (MAP), heart rate (HR), cardiac output (CO), stroke volume (SV), and regional cerebral oxygen saturation (rSO(2)) were recorded before induction of anesthesia and every 2 min after tourniquet deflation for 20 min. Arterial blood gas analysis was performed 5 min before, in addition to 0, and 10 min after tourniquet deflation. The decrease of rSO(2) was not significant during 20-min deflation period. MAP, CO and SV showed significant decrease during 2 to 12, 4 to 6 and 2 to 6-min period after tourniquet deflation, respectively (P deflation caused significant changes in hemodynamic and metabolic status, but not in regional cerebral oxygen saturation. It is recommended to monitor neurologic status, as well as hemodynamic and metabolic status to avoid serious complications, especially in aged patients.

  5. Lower early postnatal oxygen saturation target and risk of ductus arteriosus closure failure.

    Science.gov (United States)

    Inomata, Kei; Taniguchi, Shinji; Yonemoto, Hiroki; Inoue, Takeshi; Kawase, Akihiko; Kondo, Yuichi

    2016-11-01

    Early postnatal hyperoxia is a major risk factor for retinopathy of prematurity (ROP) in extremely premature infants. To reduce the occurrence of ROP, we adopted a lower early postnatal oxygen saturation (SpO 2 ) target range (85-92%) from April 2011. Lower SpO 2 target range, however, may lead to hypoxemia and an increase in the risk of ductus arteriosus (DA) closure failure. The aim of this study was therefore to determine whether a lower SpO 2 target range, during the early postnatal stage, increases the risk of DA closure failure. Infants born at closure failure in period 2 (21%) was significantly higher than that in period 1 (1%). On multivariate logistic regression analysis, the lower oxygen saturation target range was an independent risk factor for DA closure failure. Lower early postnatal oxygen saturation target range increases the risk of DA closure failure. © 2016 Japan Pediatric Society.

  6. White Matter Damage Relates to Oxygen Saturation in Children With Sickle Cell Anemia Without Silent Cerebral Infarcts.

    Science.gov (United States)

    Kawadler, Jamie M; Kirkham, Fenella J; Clayden, Jonathan D; Hollocks, Matthew J; Seymour, Emma L; Edey, Rosanna; Telfer, Paul; Robins, Andrew; Wilkey, Olu; Barker, Simon; Cox, Tim C S; Clark, Chris A

    2015-07-01

    Sickle cell anemia is associated with compromised oxygen-carrying capability of hemoglobin and a high incidence of overt and silent stroke. However, in children with no evidence of cerebral infarction, there are changes in brain morphometry relative to healthy controls, which may be related to chronic anemia and oxygen desaturation. A whole-brain tract-based spatial statistics analysis was carried out in 25 children with sickle cell anemia with no evidence of abnormality on T2-weighted magnetic resonance imaging (13 male, age range: 8-18 years) and 14 age- and race-matched controls (7 male, age range: 10-19 years) to determine the extent of white matter injury. The hypotheses that white matter damage is related to daytime peripheral oxygen saturation and steady-state hemoglobin were tested. Fractional anisotropy was found to be significantly lower in patients in the subcortical white matter (corticospinal tract and cerebellum), whereas mean diffusivity and radial diffusivity were higher in patients in widespread areas. There was a significant negative relationship between radial diffusivity and oxygen saturation (Plevel negative relationship between radial diffusivity and hemoglobin (Pcell anemia, and provides for the first time direct evidence of a relationship between brain microstructure and markers of disease severity (eg, peripheral oxygen saturation and steady-state hemoglobin). This study suggests that diffusion tensor imaging metrics may serve as a biomarker for future trials of reducing hypoxic exposure. © 2015 American Heart Association, Inc.

  7. Design of pulse oximetry signal based on personal computer for detection oxygen saturation

    International Nuclear Information System (INIS)

    Umi Salamah; Margi Sasono

    2015-01-01

    The lack or excess of oxygen in the blood will cause healthy and body system disorder. At certain level, the disease can lead to death. For that reason, the information about oxygen saturation in blood becomes important to be identified. One of the devices used to monitor the blood oxygen saturation is pulse oximetry. This research attempt to designed Pulse Oximetry based on personal computer using red LED and infrared as its light source, while the light sensor using photodiode. The designed Pulse Oximetry is a non-invasive instrumentation which LED drivers is placed on the fingertips. The LED light goes through the finger will be a signal that is fed to the photodiode and will be converted into digital signals by ADC (Analog to Digital Converter) and will be processed further by a personal computer to display the pulse oximetry graphics. This study uses Delphi 7, Microsoft Excel, and Mt Lab as its software.This designed pulse oximetry has been tested in two peoples: sample A, male 38 years; and sample B, a woman 23 years old. Oxygen saturation of sample A is 80.75, while the sample B is 90.75. (author)

  8. Blood oxygen saturation determined by transmission spectrophotometry of hemolyzed blood samples

    Science.gov (United States)

    Malik, W. M.

    1967-01-01

    Use of the Lambert-Beer Transmission Law determines blood oxygen saturation of hemolyzed blood samples. This simplified method is based on the difference in optical absorption properties of hemoglobin and oxyhemoglobin.

  9. Reliable monitoring of oxygen saturation via pulse oximetry: Which ...

    African Journals Online (AJOL)

    This study focuses on identifying the best site for placement of pulse oximeter probe accurate measuring of oxygen saturation. Twenty-three healthy male volunteers aged 20 to 40 years old were recruited in this study. Cold pressor test was done to stim 460 measurements of SpO2level were obtained throughout the study.

  10. The Choroidal Eye Oximeter - An instrument for measuring oxygen saturation of choroidal blood in vivo

    Science.gov (United States)

    Laing, R. A.; Danisch, L. A.; Young, L. R.

    1975-01-01

    The Choroidal Eye Oximeter is an electro-optical instrument that noninvasively measures the oxygen saturation of choroidal blood in the back of the human eye by a spectrophotometric method. Since choroidal blood is characteristic of blood which is supplied to the brain, the Choroidal Eye Oximeter can be used to monitor the amount of oxygen which is supplied to the brain under varying external conditions. The instrument consists of two basic systems: the optical system and the electronic system. The optical system produces a suitable bi-chromatic beam of light, reflects this beam from the fundus of the subject's eye, and onto a low-noise photodetector. The electronic system amplifies the weak composite signal from the photodetector, computes the average oxygen saturation from the area of the fundus that was sampled, and displays the value of the computed oxygen saturation on a panel meter.

  11. An efficient optimization method to improve the measuring accuracy of oxygen saturation by using triangular wave optical signal

    Science.gov (United States)

    Li, Gang; Yu, Yue; Zhang, Cui; Lin, Ling

    2017-09-01

    The oxygen saturation is one of the important parameters to evaluate human health. This paper presents an efficient optimization method that can improve the accuracy of oxygen saturation measurement, which employs an optical frequency division triangular wave signal as the excitation signal to obtain dynamic spectrum and calculate oxygen saturation. In comparison to the traditional method measured RMSE (root mean square error) of SpO2 which is 0.1705, this proposed method significantly reduced the measured RMSE which is 0.0965. It is notable that the accuracy of oxygen saturation measurement has been improved significantly. The method can simplify the circuit and bring down the demand of elements. Furthermore, it has a great reference value on improving the signal to noise ratio of other physiological signals.

  12. Study of Al-Si Alloy Oxygen Saturation on Its Microstructure and Mechanical Properties.

    Science.gov (United States)

    Finkelstein, Arkady; Schaefer, Arseny; Chikova, Оlga; Borodianskiy, Konstantin

    2017-07-11

    One of the main goals of modern materials research is obtaining different microstructures and studying their influence on the mechanical properties of metals; aluminum alloys are particularly of interest due to their advanced performance. Traditionally, their required properties are obtained by alloying process, modification, or physical influence during solidification. The present work describes a saturation of the overheated AlSi₇Fe₁ casting alloy by oxides using oxygen blowing approach in overheated alloy. Changes in metals' microstructural and mechanical properties are also described in the work. An Al 10 SiFe intermetallic complex compound was obtained as a preferable component to Al₂O₃ precipitation on it, and its morphology was investigated by scanning electron microscopy. The mechanical properties of the alloy after the oxygen blowing treatment are discussed in this work.

  13. The effect of sensory stimulation provided by family on arterial blood oxygen saturation in critical care patients.

    Science.gov (United States)

    Yousefi, Hojatollah; Naderi, Mojgan; Daryabeigi, Reza

    2015-01-01

    Stressors in the intensive care unit (ICU) impair patients' comfort, excite the stress response, and increase oxygen consumption in their body. Non-medical interventions are recommended by several studies as a treatment to improve comfort in the ICU patients. Sensory stimulation is one of the most important interventions. Since arterial blood oxygen saturation is an important index of patients' clinical and respiratory condition, this study aimed to investigate the effect of sensory stimulation provided by family on arterial blood oxygen saturation in critical care patients. This study is a clinical trial conducted on 64 patients hospitalized in the ICU wards of Al-Zahra and Kashani hospitals in Isfahan, Iran in 2012 and 2013. The patients were selected by simple sampling method and were randomly assigned to two groups (study and control). Patients' arterial blood oxygen saturations were measured 10 min before, immediately after, 10 min and 30 min after sensory stimulation in the study group, and simultaneously in the control group without any intervention. Repeated measures analysis of variance (ANOVA) showed a significant difference in the mean of arterial blood oxygen saturation levels 10 min before, immediately after, 10 min and 30 min after sensory stimulation in the study group (P 0.18). Application of sensory stimulations as a nursing and non-medical intervention by the family members improves comfort and increases the level of blood oxygen saturation in critical care patients.

  14. A technique for measuring oxygen saturation in biological tissues based on diffuse optical spectroscopy

    Science.gov (United States)

    Kleshnin, Mikhail; Orlova, Anna; Kirillin, Mikhail; Golubiatnikov, German; Turchin, Ilya

    2017-07-01

    A new approach to optical measuring blood oxygen saturation was developed and implemented. This technique is based on an original three-stage algorithm for reconstructing the relative concentration of biological chromophores (hemoglobin, water, lipids) from the measured spectra of diffusely scattered light at different distances from the probing radiation source. The numerical experiments and approbation of the proposed technique on a biological phantom have shown the high reconstruction accuracy and the possibility of correct calculation of hemoglobin oxygenation in the presence of additive noise and calibration errors. The obtained results of animal studies have agreed with the previously published results of other research groups and demonstrated the possibility to apply the developed technique to monitor oxygen saturation in tumor tissue.

  15. COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE

    Directory of Open Access Journals (Sweden)

    Muhaji

    2017-12-01

    Full Text Available Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU, which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for patients with endotracheal tube. Objective: To compare the effectiveness of 130 mmHg and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube. Methods: This research used a quasy experimental design with pretest and posttest group. The study was conducted from 31 January to 1 March 2017 in the Hospital of Panti Wilasa Citarum and Hospital of Roemani Muhammadiyah Semarang. There were 30 samples recruited using consecutive sampling, with 15 assigned in the 130 mmHg and 140 mmHg suctioning pressure group. Pulse oximetry was used to measure oxygen saturation. Paired t-test and Independent t-test were used for data analysis. Results: Findings showed that there was a statistically significant effect of 130 and 140 mmHg suctioning pressure on oxygen saturation in patients with ETT with p-value <0.05. There was a significant mean difference of oxygen saturation between 130 mmHg and 140 mmHg suctioning pressure group with p-value 0.004 (<0.05. The mean difference of oxygen saturation between both groups was 13.157. Conclusion: The 140 mmHg suctioning pressure is more effective compared with 130 mmHg suctioning pressure in increasing oxygen saturation in patients with ETT.

  16. Comparison of oxygen saturation values obtained from fingers on physically restrained or unrestrained sides of the body.

    Science.gov (United States)

    Korhan, Esra Akin; Yönt, Gülendam Hakverdioğlu; Khorshid, Leyla

    2011-01-01

    The aim of this study was to compare semiexperimentally the pulse oximetry values obtained from a finger on restrained or unrestrained sides of the body. The pulse oximeter provides a noninvasive measurement of the oxygen saturation of hemoglobin in arterial blood. One of the procedures most frequently applied to patients in intensive care units is the application of physical restraint. Circulation problems are the most important complication in patients who are physically restrained. Evaluation of oxygen saturation from body parts in which circulation is impeded or has deteriorated can cause false results. The research sample consisted of 30 hospitalized patients who participated in the study voluntarily and who were concordant with the inclusion criteria of the study. Patient information and patient follow-up forms were used for data collection. Pulse oximetry values were measured simultaneously using OxiMax Nellcor finger sensors from fingers on the restrained and unrestrained sides of the body. Numeric and percentile distributions were used in evaluating the sociodemographic properties of patients. A significant difference was found between the oxygen saturation values obtained from a finger of an arm that had been physically restrained and a finger of an arm that had not been physically restrained. The mean oxygen saturation value measured from a finger of an arm that had been physically restrained was found to be 93.40 (SD, 2.97), and the mean oxygen saturation value measured from a finger of an arm that had not been physically restrained was found to be 95.53 (SD, 2.38). The results of this study indicate that nurses should use a finger of an arm that is not physically restrained when evaluating oxygen saturation values to evaluate them correctly.

  17. Measurement of brain oxygenation changes using dynamic T1-weighted imaging

    DEFF Research Database (Denmark)

    Haddock, Bryan; Larsson, Henrik B W; Hansen, Adam E

    2013-01-01

    Magnetic resonance imaging (MRI) has proven useful in evaluating oxygenation in several types of tissue and blood. This study evaluates brain tissue oxygenation changes between normoxia and hyperoxia in healthy subjects using dynamic T1 and T2*-weighted imaging sequences. The change in FiO2 induced...... by hyperoxia caused a significant decrease in T1. A model to determine changes in tissue oxygen tension from the T1-weighted MRI signal is presented based on previous findings that T1 is sensitive to oxygen tension whereas T2* is sensitive to blood saturation. The two sequences produce results with different...... regional and temporal dynamics. These differences combined with results from simulations of the T1 signal intensities, indicate an increase in extravascular oxygen tension during hyperoxia. This study concludes that T1 and T2* responses to FiO2 serve as independent biomarkers of oxygen physiology...

  18. Study of Al-Si Alloy Oxygen Saturation on Its Microstructure and Mechanical Properties

    Directory of Open Access Journals (Sweden)

    Arkady Finkelstein

    2017-07-01

    Full Text Available One of the main goals of modern materials research is obtaining different microstructures and studying their influence on the mechanical properties of metals; aluminum alloys are particularly of interest due to their advanced performance. Traditionally, their required properties are obtained by alloying process, modification, or physical influence during solidification. The present work describes a saturation of the overheated AlSi7Fe1 casting alloy by oxides using oxygen blowing approach in overheated alloy. Changes in metals’ microstructural and mechanical properties are also described in the work. An Al10SiFe intermetallic complex compound was obtained as a preferable component to Al2O3 precipitation on it, and its morphology was investigated by scanning electron microscopy. The mechanical properties of the alloy after the oxygen blowing treatment are discussed in this work.

  19. Lung vital capacity and oxygen saturation in adults with cerebral palsy

    Directory of Open Access Journals (Sweden)

    Lampe R

    2014-12-01

    Full Text Available Renée Lampe,1,2 Tobias Blumenstein,2 Varvara Turova,2 Ana Alves-Pinto2 1Markus Würth Stiftungsprofessur, Technical University of Munich, Munich, Germany; 2Research Unit for Cerebral Palsy and Children Neuroorthopaedics of the Buhl-Strohmaier Foundation, Orthopedic Department of the Clinic “rechts der Isar” of the Technical University of Munich, Munich, Germany Background: Individuals with infantile cerebral palsy have multiple disabilities. The most conspicuous syndrome being investigated from many aspects is motor movement disorder with a spastic gait pattern. The lung function of adults with spasticity attracts less attention in the literature. This is surprising because decreased thoracic mobility and longstanding scoliosis should have an impact on lung function. With increasing age and the level of disability, individuals become susceptible to lung infections and reflux illness, and these are accompanied by increased aspiration risk. This study examined, with different methods, to what extent adults with congenital cerebral palsy and acquired spastic paresis – following traumatic brain injury – showed restriction of lung function. It also assessed the contribution of disability level on this restriction.Methods: The oxygen saturation of 46 adults with a diagnosis of cerebral palsy was measured with an oximeter. Lung vital capacity was measured with a mobile spirometer and excursion of the thorax was clinically registered. The gross motor function levels and the presence or absence of scoliosis were determined.Results: A significantly positive correlation between lung vital capacity and chest expansion was established. Both the lung vital capacity and the thorax excursion decreased with increases in gross motor function level. Oxygen saturation remained within the normal range in all persons, in spite of reduced values of the measured lung parameters. No statistically significant dependency between lung vital capacity and oxygen

  20. Cerebral tissue oxygen saturation and extraction in preterm infants before and after blood transfusion

    NARCIS (Netherlands)

    van Hoften, Jacorina C. R.; Verhagen, Elise A.; Keating, Paul; ter Horst, Hendrik J.; Bos, Arend F.

    Objective Preterm infants often need red blood cell (RBC) transfusions. The aim of this study was to determine whether haemoglobin levels before transfusion were associated with regional cerebral tissue oxygen saturation (r(c)SO(2)) and fractional tissue oxygen extraction (FTOE) and whether RBC

  1. The Relationship between Oxygen Saturation and Color Alteration of a Compromised Skin Flap: Experimental Study on the Rabbit.

    Science.gov (United States)

    Prasetyono, Theddeus O H; Adianto, Senja

    2013-09-01

    The aim of this study was to collect important data on the time of oxygen saturation change in relation to skin flap color alteration using non-invasive pulse oximetry to evaluate its ability to provide continuous monitoring of skin flap perfusion. An experimental study on the monitoring of blood perfusion of 20 tube-island groin flaps of 10 male New Zealand rabbits was performed using pulse oximetry. The animals were randomly assigned to one of two groups representing a blockage of either arterial or venous blood flow. The oxygen saturation change and clinical color alteration were monitored from the beginning of vessel clamping until the saturation became undetectable. The result was analyzed by the t-test using SSPS ver. 10.0. The mean times from the vessel clamping until the saturation became undetectable were 20.19±2.13 seconds and 74.91±10.57 seconds for the artery and vein clamping groups, respectively. The mean time of the clinical alteration from the beginning of vein clamping was 34.5±11.72 minutes, while the alteration in flaps with artery clamping could not be detected until 2.5 hours after clamping. The use of neonate-type reusable flex sensor-pulse oximetry is objective and effective in early detection of arterial and vein blockage. It provides real-time data on vessel occlusion, which in turn will allow for early salvaging. The detection periods of both arterial occlusion and venous congestion are much earlier than the color alteration one may encounter clinically.

  2. The Relationship between Oxygen Saturation and Color Alteration of a Compromised Skin Flap: Experimental Study on the Rabbit

    Directory of Open Access Journals (Sweden)

    Theddeus O. H. Prasetyono

    2013-09-01

    Full Text Available BackgroundThe aim of this study was to collect important data on the time of oxygen saturation change in relation to skin flap color alteration using non-invasive pulse oximetry to evaluate its ability to provide continuous monitoring of skin flap perfusion.MethodsAn experimental study on the monitoring of blood perfusion of 20 tube-island groin flaps of 10 male New Zealand rabbits was performed using pulse oximetry. The animals were randomly assigned to one of two groups representing a blockage of either arterial or venous blood flow. The oxygen saturation change and clinical color alteration were monitored from the beginning of vessel clamping until the saturation became undetectable. The result was analyzed by the t-test using SSPS ver. 10.0.ResultsThe mean times from the vessel clamping until the saturation became undetectable were 20.19±2.13 seconds and 74.91±10.57 seconds for the artery and vein clamping groups, respectively. The mean time of the clinical alteration from the beginning of vein clamping was 34.5±11.72 minutes, while the alteration in flaps with artery clamping could not be detected until 2.5 hours after clamping.ConclusionsThe use of neonate-type reusable flex sensor-pulse oximetry is objective and effective in early detection of arterial and vein blockage. It provides real-time data on vessel occlusion, which in turn will allow for early salvaging. The detection periods of both arterial occlusion and venous congestion are much earlier than the color alteration one may encounter clinically.

  3. Dependence of diameters and oxygen saturation of retinal vessels on visual field damage and age in primary open-angle glaucoma.

    Science.gov (United States)

    Ramm, Lisa; Jentsch, Susanne; Peters, Sven; Sauer, Lydia; Augsten, Regine; Hammer, Martin

    2016-05-01

    To investigate the interrelationship between the oxygen supply of the retina and its regulation with the severity of primary open-angle glaucoma (POAG). Central retinal artery (CRAE) and vein (CRVE) diameters and oxygen saturation of peripapillary retinal vessels in 41 patients suffering from POAG (64.1 ± 12.9 years) and 40 healthy volunteers (63.6 ± 14.1 years) were measured using the retinal vessel analyzer. All measures were taken before and during flicker light stimulation. The mean retinal nerve fiber layer thickness (RNFLT) was determined by OCT and the visual field mean defect (MD) was identified using perimetry. In glaucoma patients, CRAE (r = -0.48 p = 0.002) and CRVE (r = -0.394 p = 0.014) at baseline were inversely related to MD, while arterial and venous oxygen saturation showed no significant dependence on the severity of the damage. However, the flicker light-induced change in arterio-venous difference in oxygen saturation was correlated with the MD (r = 0.358 p = 0.027). The diameters of arteries and veins at baseline decreased with reduction of the mean RNFLT (arteries: r = 0.718 p field loss, may be explained by a reduction of the retinal metabolic demand with progressive loss of neuronal tissue in glaucoma. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. Effects of Changes in Arterial Carbon Dioxide and Oxygen Partial Pressures on Cerebral Oximeter Performance.

    Science.gov (United States)

    Schober, Andrew; Feiner, John R; Bickler, Philip E; Rollins, Mark D

    2018-01-01

    Cerebral oximetry (cerebral oxygen saturation; ScO2) is used to noninvasively monitor cerebral oxygenation. ScO2 readings are based on the fraction of reduced and oxidized hemoglobin as an indirect estimate of brain tissue oxygenation and assume a static ratio of arterial to venous intracranial blood. Conditions that alter cerebral blood flow, such as acute changes in PaCO2, may decrease accuracy. We assessed the performance of two commercial cerebral oximeters across a range of oxygen concentrations during normocapnia and hypocapnia. Casmed FORE-SIGHT Elite (CAS Medical Systems, Inc., USA) and Covidien INVOS 5100C (Covidien, USA) oximeter sensors were placed on 12 healthy volunteers. The fractional inspired oxygen tension was varied to achieve seven steady-state levels including hypoxic and hyperoxic PaO2 values. ScO2 and simultaneous arterial and jugular venous blood gas measurements were obtained with both normocapnia and hypocapnia. Oximeter bias was calculated as the difference between the ScO2 and reference saturation using manufacturer-specified weighting ratios from the arterial and venous samples. FORE-SIGHT Elite bias was greater during hypocapnia as compared with normocapnia (4 ± 9% vs. 0 ± 6%; P oxygen saturation and mixed venous oxygen tension, as well as increased oxygen extraction across fractional inspired oxygen tension levels (P oxygen extraction (P < 0.0001). Changes in PaCO2 affect cerebral oximeter accuracy, and increased bias occurs with hypocapnia. Decreased accuracy may represent an incorrect assumption of a static arterial-venous blood fraction. Understanding cerebral oximetry limitations is especially important in patients at risk for hypoxia-induced brain injury, where PaCO2 may be purposefully altered.

  5. Oxygen breathing accelerates decompression from saturation at 40 msw in 70-kg swine.

    Science.gov (United States)

    Petersen, Kyle; Soutiere, Shawn E; Tucker, Kathryn E; Dainer, Hugh M; Mahon, Richard T

    2010-07-01

    Submarine disaster survivors can be transferred from a disabled submarine at a pressure of 40 meters of seawater (msw) to a new rescue vehicle; however, they face an inherently risky surface interval before recompression and an enormous decompression obligation due to a high likelihood of saturation. The goal was to design a safe decompression protocol using oxygen breathing and a trial-and-error methodology. We hypothesized that depth, timing, and duration of oxygen breathing during decompression from saturation play a role to mitigate decompression outcomes. Yorkshire swine (67-75 kg), compressed to 40 msw for 22 h, underwent one of three accelerated decompression profiles: (1) 13.3 h staged air decompression to 18 msw, followed by 1 h oxygen breathing, then dropout; (2) direct decompression to 18 msw followed by 1 h oxygen breathing then dropout; and (3) 1 h oxygen prebreathe at 40 msw followed by 1 h mixed gas breathing at 26 msw, 1 h oxygen breathing at 18 msw, and 1 h ascent breathing oxygen. Animals underwent 2-h observation for signs of DCS. Profile 1 (14.3 h total) resulted in no deaths, no Type II DCS, and 20% Type I DCS. Profile 2 (2.1 h total) resulted in 13% death, 50% Type II DCS, and 75% Type I DCS. Profile 3 (4.5 h total) resulted in 14% death, 21% Type II DCS, and 57% Type I DCS. No oxygen associated seizures occurred. Profile 1 performed best, shortening decompression with no death or severe DCS, yet it may still exceed emergency operational utility in an actual submarine rescue.

  6. Evaluation of different near-infrared spectroscopy technologies for assessment of tissue oxygen saturation during a vascular occlusion test.

    Science.gov (United States)

    Steenhaut, Kevin; Lapage, Koen; Bové, Thierry; De Hert, Stefan; Moerman, Annelies

    2017-12-01

    An increasing number of NIRS devices are used to provide measurements of peripheral tissue oxygen saturation (S t O 2 ). The aim of the present study is to test the hypothesis that despite technological differences between devices, similar trend values will be obtained during a vascular occlusion test. The devices compared are NIRO-200NX, which measures S t O 2 and oxyhemoglobin by spatially resolved spectroscopy and the Beer-Lambert law, respectively, and INVOS 5100C and Foresight Elite, which both measure S t O 2 with the Beer-Lambert law, enhanced with the spatial resolution technique. Forty consenting adults scheduled for CABG surgery were recruited. The respective sensors of the three NIRS devices were applied over the brachioradial muscle. Before induction of anesthesia, 3 min of ischemia were induced by inflating a blood pressure cuff at the upper arm, whereafter cuff pressure was rapidly released. Tissue oxygenation measurements included baseline, minimum and maximum values, desaturation and resaturation slopes, and rise time. Comparisons between devices were performed with the Kruskal-Wallis test with post hoc Mann-Whitney pairwise comparisons. Agreement was evaluated using Bland-Altman plots. Oxyhemoglobin measured with NIRO responded faster than the other NIRS technologies to changes in peripheral tissue oxygenation (20 vs. 27-40 s, p ≤ 0.01). When comparing INVOS with Foresight, oxygenation changes were prompter (upslope 311 [92-523]%/min vs. 114[65-199]%/min, p ≤ 0.01) and more pronounced (minimum value 36 [21-48] vs. 45 [40-51]%, p ≤ 0.01) with INVOS. Significant differences in tissue oxygen saturation measurements were observed, both within the same device as between different devices using the same measurement technology.

  7. Lack of differences in the regional variation of oxygen saturation in larger retinal vessels in diabetic maculopathy and proliferative diabetic retinopathy.

    Science.gov (United States)

    Jørgensen, Christina Mørup; Bek, Toke

    2017-06-01

    Diabetic retinopathy is characterised by morphological lesions in the ocular fundus related to disturbances in retinal blood flow. The two vision threatening forms of retinopathy show specific patterns of distribution of retinal lesions with proliferative diabetic retinopathy (PDR) developing secondary to ischaemia and hypoxia in the retinal periphery and diabetic maculopathy (DM) developing secondary to hyperperfusion and increased vascular permeability in the macular area. These differences in the distribution of retinal lesions might be reflected in regional differences in oxygen saturation in the larger retinal vessels. Dual-wavelength retinal oximetry was performed in 30 normal persons, 30 patients with DM and 30 patients with PDR, and the oxygen saturation was measured in peripapillary vessels supplying the four retinal quadrants and in branches from the upper temporal arcades supplying, respectively, the macular area and the retinal periphery. The overall oxygen saturation was significantly higher in diabetic patients than in normal persons and the arteriovenous (AV) saturation difference significantly lower in the patients with DM. The regional variation in oxygen saturation was similar in the three studied groups with a decreasing saturation from the upper nasal through the lower nasal, lower temporal and the upper temporal peripapillary vessels, and with a significantly higher oxygen saturation in venules draining the macular area than in venules draining the retinal periphery. The regional differences in retinal lesions in vision threatening diabetic retinopathy are not reflected in regional differences in the oxygen saturation of larger retinal vessels. The development of vision threatening diabetic retinopathy depends on other factors, such as, for example, regional differences in the retinal microcirculation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. Nitric oxide formation from the reaction of nitrite with carp and rabbit hemoglobin at intermediate oxygen saturations

    DEFF Research Database (Denmark)

    Jensen, Frank Bo

    2008-01-01

    The nitrite reductase activity of deoxyhemoglobin has received much recent interest because the nitric oxide produced in this reaction may participate in blood flow regulation during hypoxia. The present study used spectral deconvolution to characterize the reaction of nitrite with carp and rabbit...... hemoglobin at different constant oxygen tensions that generate the full range of physiological relevant oxygen saturations. Carp is a hypoxia-tolerant species with very high hemoglobin oxygen affinity, and the high R-state character and low redox potential of the hemoglobin is hypothesized to promote...... NO generation from nitrite. The reaction of nitrite with deoxyhemoglobin leads to a 1 : 1 formation of nitrosylhemoglobin and methemoglobin in both species. At intermediate oxygen saturations, the reaction with deoxyhemoglobin is clearly favored over that with oxyhemoglobin, and the oxyhemoglobin reaction...

  9. [Monitorization of the effects of spinal anaesthesia on cerebral oxygen saturation in elder patients using near-infrared spectroscopy].

    Science.gov (United States)

    Kusku, Aysegul; Demir, Guray; Cukurova, Zafer; Eren, Gulay; Hergunsel, Oya

    2014-01-01

    Central blockage provided by spinal anaesthesia enables realization of many surgical procedures, whereas hemodynamic and respiratory changes influence systemic oxygen delivery leading to the potential development of series of problems such as cerebral ischemia, myocardial infarction and acute renal failure. This study was intended to detect potentially adverse effects of hemodynamic and respiratory changes on systemic oxygen delivery using cerebral oxymetric methods in patients who underwent spinal anaesthesia. Twenty-five ASA I-II Group patients aged 65-80 years scheduled for unilateral inguinal hernia repair under spinal anaesthesia were included in the study. Following standard monitorization baseline cerebral oxygen levels were measured using cerebral oximetric methods. Standardized Mini Mental Test (SMMT) was applied before and after the operation so as to determine the level of cognitive functioning of the cases. Using a standard technique and equal amounts of a local anaesthetic drug (15mg bupivacaine 5%) intratechal blockade was performed. Mean blood pressure (MBP), maximum heart rate (MHR), peripheral oxygen saturation (SpO2) and cerebral oxygen levels (rSO2) were preoperatively monitored for 60min. Pre- and postoperative haemoglobin levels were measured. The variations in data obtained and their correlations with the cerebral oxygen levels were investigated. Significant changes in pre- and postoperative measurements of haemoglobin levels and SMMT scores and intraoperative SpO2 levels were not observed. However, significant variations were observed in intraoperative MBP, MHR and rSO2 levels. Besides, a correlation between variations in rSO2, MBP and MHR was determined. Evaluation of the data obtained in the study demonstrated that post-spinal decline in blood pressure and also heart rate decreases systemic oxygen delivery and adversely effects cerebral oxygen levels. However, this downward change did not result in deterioration of cognitive functioning

  10. Monitorization of the effects of spinal anaesthesia on cerebral oxygen saturation in elder patients using near-infrared spectroscopy.

    Science.gov (United States)

    Kusku, Aysegul; Demir, Guray; Cukurova, Zafer; Eren, Gulay; Hergunsel, Oya

    2014-01-01

    Central blockage provided by spinal anaesthesia enables realization of many surgical procedures, whereas hemodynamic and respiratory changes influence systemic oxygen delivery leading to the potential development of series of problems such as cerebral ischemia, myocardial infarction and acute renal failure. This study was intended to detect potentially adverse effects of hemodynamic and respiratory changes on systemic oxygen delivery using cerebral oxymetric methods in patients who underwent spinal anaesthesia. Twenty-five ASA I-II Group patients aged 65-80 years scheduled for unilateral inguinal hernia repair under spinal anaesthesia were included in the study. Following standard monitorization baseline cerebral oxygen levels were measured using cerebral oximetric methods. Standardized Mini Mental Test (SMMT) was applied before and after the operation so as to determine the level of cognitive functioning of the cases. Using a standard technique and equal amounts of a local anaesthetic drug (15mg bupivacaine 5%) intratechal blockade was performed. Mean blood pressure (MBP), maximum heart rate (MHR), peripheral oxygen saturation (SpO2) and cerebral oxygen levels (rSO2) were preoperatively monitored for 60min. Pre- and postoperative haemoglobin levels were measured. The variations in data obtained and their correlations with the cerebral oxygen levels were investigated. Significant changes in pre- and postoperative measurements of haemoglobin levels and SMMT scores and intraoperative SpO2 levels were not observed. However, significant variations were observed in intraoperative MBP, MHR and rSO2 levels. Besides, a correlation between variations in rSO2, MBP and MHR was determined. Evaluation of the data obtained in the study demonstrated that post-spinal decline in blood pressure and also heart rate decreases systemic oxygen delivery and adversely effects cerebral oxygen levels. However, this downward change did not result in deterioration of cognitive functioning

  11. Photoirradiation system with depth optical dosimetry control in initial oxygen saturation measurement

    International Nuclear Information System (INIS)

    Quintanar, L.; Stolik, S.; Rosa, J. de la; Moreno, E.

    2012-01-01

    Photodynamic Therapy is a technique in which a photosensitizing substance is applied that is activated by light and it generates reactive oxygen species which cause selective cell destruction. The efficiency of the therapy is affected by the parameters dose. In this work it is shown a photo-irradiation system for superficial Photodynamic Therapy, using as a light source a light emitting diode with an automatic control of optical power based on a model of the distribution of light in depth that was tested in tissue phantoms. It also has a reflective pulse oximeter for the measurement of the initial oxygen saturation. (Author)

  12. Detection of cerebral arterial gas embolism using regional cerebral oxygen saturation, quantitative electroencephalography, and brain oxygen tension in the swine

    NARCIS (Netherlands)

    Weenink, R. P.; Hollmann, M. W.; Stevens, M. F.; Kager, J.; van Gulik, T. M.; van Hulst, R. A.

    2014-01-01

    Cerebral air emboli occur as a complication of invasive medical procedures. The sensitivity of cerebral monitoring methods for the detection of air emboli is not known. This study investigates the utility of electroencephalography and non-invasively measured cerebral oxygen saturation in the

  13. Simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in humans and other animal models using a single light source

    Science.gov (United States)

    Dent, Paul; Tun, Sai Han; Fillioe, Seth; Deng, Bin; Satalin, Josh; Nieman, Gary; Wilcox, Kailyn; Searles, Quinn; Narsipur, Sri; Peterson, Charles M.; Goodisman, Jerry; Mostrom, James; Steinmann, Richard; Chaiken, J.

    2018-02-01

    We previously reported a new algorithm "PV[O]H" for continuous, noninvasive, in vivo monitoring of hematocrit changes in blood and have since shown its utility for monitoring in humans during 1) hemodialysis, 2) orthostatic perturbations and 3) during blood loss and fluid replacement in a rat model. We now show that the algorithm is sensitive to changes in hemoglobin oxygen saturation. We document the phenomenology of the effect and explain the effect using new results obtained from humans and rat models. The oxygen sensitivity derives from the differential absorption of autofluorescence originating in the static tissues by oxy and deoxy hemoglobin. Using this approach we show how to perform simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in mammals using a single light source. We suspect that monitoring of changes in this suite of vital signs can be provided with improved time response, sensitivity and precision compared to existing methodologies. Initial results also offer a more detailed glimpse into the systemic oxygen transport in the circulatory system of humans.

  14. Developmental Effects Determine Submaximal Arterial Oxygen Saturation in Peruvian Quechua.

    Science.gov (United States)

    Kiyamu, Melisa; León-Velarde, Fabiola; Rivera-Chira, María; Elías, Gianpietro; Brutsaert, Tom D

    2015-06-01

    Kiyamu, Melisa, Fabiola León-Velarde, María Rivera-Chira, Gianpietro Elías, and Tom D. Brutsaert. Developmental effects determine submaximal arterial oxygen saturation in Peruvian Quechua. High Alt Med Biol 16, 138-146, 2015.--Andean high altitude natives show higher arterial oxygen saturation (Sao(2)) during exercise in hypoxia, compared to acclimatized sojourners. In order to evaluate the effects of life-long exposure to high altitude on Sao(2), we studied two groups of well-matched, self-identified Peruvian Quechua natives who differed in their developmental exposure to hypoxia before and after a 2-month training period. Male and female volunteers (18-35 years) were recruited in Lima, Peru (150 m). The two groups were: a) Individuals who were born and raised at sea-level (BSL, n=34) and b) Individuals who were born and raised at high altitude (BHA, n=32), but who migrated to sea-level as adults (>16 years old). Exercise testing was conducted using a submaximal exercise protocol in normobaric hypoxia in Lima (BP=750 mmHg, Fio(2)=0.12), in order to measure Sao(2) (%), ventilation (VE L/min) and oxygen consumption (Vo(2), L/min). Repeated-measures ANOVA, controlling for VE/VO(2) (L/min) and sex during the submaximal protocol showed that BHA maintained higher Sao(2) (%) compared to BSL at all workloads before (p=0.005) and after training (p=0.017). As expected, both groups showed a decrease in Sao(2) (%) (p<0.001), as workload increased. Resting Sao(2) levels were not found to be different between groups. The results suggest that developmental exposure to altitude contributes to the maintenance of higher Sao(2) levels during submaximal exercise at hypoxia.

  15. Growth of the microalgae Neochloris oleoabundans at high partial oxygen pressures and sub-saturating light intensity

    NARCIS (Netherlands)

    Sousa, C.A.; Winter, de L.; Janssen, M.G.J.; Vermue, M.H.; Wijffels, R.H.

    2012-01-01

    The effect of partial oxygen pressure on growth of Neochloris oleoabundans was studied at sub-saturating light intensity in a fully-controlled stirred tank photobioreactor. At the three partial oxygen pressures tested (PO2=0.24; 0.63; 0.84 bar), the specific growth rate was 1.38; 1.36 and 1.06

  16. Comparison of oxygen saturation values and measurement times by pulse oximetry in various parts of the body.

    Science.gov (United States)

    Yönt, Gülendam Hakverdioğlu; Korhan, Esra Akin; Khorshid, Leyla

    2011-11-01

    The aim of this study, which included 40 patients, was to compare the values pulse oximetry and the measurement times in various regions of the body. Data were analyzed using intraclass correlation coefficient test and paired-sample test. The confidence power value was found to be .81 for the comparison of oxygen saturation values by arterial blood gas analysis and measurement by the forehead probe. It was found that the time for oxygen saturation measurement using the forehead probe was shorter than those using the finger and toe probes. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. [Near-infrared spectroscopy in sepsis therapy : predictor of a low central venous oxygen saturation].

    Science.gov (United States)

    Lichtenstern, C; Koch, C; Röhrig, R; Rosengarten, B; Henrich, M; Weigand, M A

    2012-10-01

    Early goal-directed hemodynamic optimization has become a cornerstone of sepsis therapy. One major defined goal is to achieve adequate central venous oxygen saturation (SO(2)). This study aimed to investigate the correlation between central venous SO(2) and frontal cerebral near-infrared spectroscopy (NIRS) measurement in patients with severe sepsis and septic shock. The NIRS method provides non-invasive measurement of regional oxygen saturation (rSO(2)) in tissues approximately 2 cm below the optical NIRS sensors which depends on arterial, capillary and venous blood. Thus this system gives site-specific real-time data about the balance of oxygen supply and demand. This was a secondary analysis from a prospective study of surgical intensive care (ICU) patients in the early phase of severe sepsis or septic shock. Bilateral cerebral rSO(2), central venous SO(2), arterial oxygen saturation (S(a)O(2)) and other surrogate parameters of oxygen supply, such as hemoglobin, partial pressure of oxygen and oxygen content in arterial blood were recorded. A total of 16 ICU patients (4 women, median age 65.5 years) were included in the study. As sepsis focus an intra-abdominal infection was detected in 62.5 % of patients, severe pneumonia was determined in 31.3 % and skin and soft tissue infections were recognized in 12.5 %. At study inclusion 50 % of patients had septic shock, the median sequential organ failure assessment (SOFA) score was 10.2 (interquartile range 5.25-8.75) and the median acute physiology and chronic health evaluation II (APACHE II) score was 26 (range 23.25-29.75). Mortality at day 28 was 37.5 %. Minimum rSO(2) (median 58) and right-sided rSO(2) (median 58) values showed a significant correlation in the analysis of receiver operating characteristics (area under the curve 0.844, p= 0.045). A central venous SO(2)< 70 % was indicated by rSO(2)< 56.5 with sensitivity and specificity of 75 % and 100 %, respectively. Cerebral NIRS could provide a fast and easily

  18. Degradation of phospholipids under different types of irradiation and varying oxygen saturation

    Czech Academy of Sciences Publication Activity Database

    Vyšín, Luděk; Tomanová, K.; Pavelková, T.; Wagner, Richard; Davídková, Marie; Múčka, V.; Čuba, V.; Juha, Libor

    2017-01-01

    Roč. 56, č. 3 (2017), s. 241-247 ISSN 0301-634X R&D Projects: GA ČR GA13-28721S; GA ČR(CZ) GBP108/12/G108; GA MŠk LM2015056 Institutional support: RVO:68378271 ; RVO:61389005 Keywords : lipid peroxidation * DOPC * gamma rays * eectrons * protons * oxygen saturation Subject RIV: BO - Biophysics OBOR OECD: Biophysics Impact factor: 2.398, year: 2016

  19. Change in the work function of zirconium by oxidation at high temperatures and low oxygen pressures

    International Nuclear Information System (INIS)

    Maeno, Yutaka; Yamamoto, Masahiro; Naito, Shizuo; Mabuchi, Mahito; Hashino, Tomoyasu

    1991-01-01

    Changes in the work function of zirconium on oxidation are measured at oxygen pressures of 3.0 x 10 -6 - 3.0 x 10 -4 Pa and at temperatures in the range 426-775 K. The work function first decreases then increases until a final saturation stage is reached. Use of secondary-ion mass spectroscopy (SIMS) shows that the changes correspond to oxygen adsorption, oxide nucleation and oxide growth, respectively. The initial decrease in work function is interpreted by the incorporation of oxygen adatoms into the subsurface. The oxygen adsorption potential of zirconium is evaluated by an effective medium theory, and the physical origin of the incorporation of oxygen adatoms is discussed. The positive change in the work function caused by oxide formation and the temperature and pressure dependences of the change in the work function by oxidation are explained qualitatively. (author)

  20. [Tissue oxygen saturation in the critically ill patient].

    Science.gov (United States)

    Gruartmoner, G; Mesquida, J; Baigorri, F

    2014-05-01

    Hemodynamic resuscitation seeks to correct global macrocirculatory parameters of pressure and flow. However, current evidence has shown that despite the normalization of these global parameters, microcirculatory and regional perfusion alterations can persist, and these alterations have been independently associated with a poorer patient prognosis. This in turn has lead to growing interest in new technologies for exploring regional circulation and microcirculation. Near infra-red spectroscopy allows us to monitor tissue oxygen saturation, and has been proposed as a noninvasive, continuous and easy-to-obtain measure of regional circulation. The present review aims to summarize the existing evidence on near infra-red spectroscopy and its potential clinical role in the resuscitation of critically ill patients in shock. Copyright © 2013 Elsevier España, S.L. and SEMICYUC. All rights reserved.

  1. Central venous oxygen saturation in septic shock - a marker of cardiac output, microvascular shunting and/or dysoxia?

    DEFF Research Database (Denmark)

    Haase, Nicolai; Perner, Anders

    2011-01-01

    Shock therapy aims at increasing central venous oxygen saturation (ScvO2), which is a marker of inadequate oxygen delivery. In this issue of Critical Care, Textoris and colleagues challenge this notion by reporting that high levels of ScvO2 are associated with mortality in patients with septic sh...

  2. Saturation volume changes and resistivity changes in nickel

    International Nuclear Information System (INIS)

    Birtcher, R.C.; Blewitt, T.H.

    1976-01-01

    Saturation defect concentrations generated by thermal neutron irradiation of 235 U doped nickel at liquid helium temperature were measured by changes in electrical resistivity and volume. The experimental procedure is described

  3. The effects of arterial carbon dioxide partial pressure and sevoflurane on capillary venous cerebral blood flow and oxygen saturation during craniotomy.

    Science.gov (United States)

    Klein, Klaus Ulrich; Glaser, Martin; Reisch, Robert; Tresch, Achim; Werner, Christian; Engelhard, Kristin

    2009-07-01

    Intraoperative routine monitoring of cerebral blood flow and oxygenation remains a technological challenge. Using the physiological principle of carbon dioxide reactivity of cerebral vasculature, we investigated a recently developed neuromonitoring device (oxygen-to-see, O2C device) for simultaneous measurements of regional cerebral blood flow (rvCBF), blood flow velocity (rvVelo), oxygen saturation (srvO2), and hemoglobin amount (rvHb) at the capillary venous level in patients subjected to craniotomy. Twenty-six neurosurgical patients were randomly assigned to anesthesia with 1.4% or 2.0% sevoflurane end-tidal concentration. After craniotomy, a fiberoptic probe was applied on a macroscopically healthy surface of cerebral tissue next to the site of surgery. Simultaneous measurements in 2 and 8 mm cerebral depth were performed in each patient during lower (35 mm Hg) and higher (45 mm Hg) levels (random order) of arterial carbon dioxide partial pressure (PaCO2). The principle of these measurements relies on the combination of laser-Doppler flowmetry (rvCBF, rvVelo) and photo-spectrometry (srvO2, rvHb). Linear models were fitted to test changes of end points (rvCBF, rvVelo, srvO2, rvHb) in response to lower and higher levels of PaCO2, 1.4% and 2.0% sevoflurane end-tidal concentration, and 2 and 8 mm cerebral depth. RvCBF and rvVelo were elevated by PaCO2 independent of sevoflurane concentration in 2 and 8 mm depth of cerebral tissue (P oxygen was decreased by elevated PaCO2. Unchanged levels of rvHb signify that there was no blood loss during measurements. Data suggest that the device allows detection of local changes in blood flow and oxygen saturation in response to different PaCO2 levels in predominant venous cerebral microvessels.

  4. Low-cost but accurate radioactive logging for determining gas saturation in a reservior

    International Nuclear Information System (INIS)

    Neuman, C.H.

    1976-01-01

    A method is disclosed for determining gas saturation in a petroleum reservoir using logging signals indirectly related to the abundances of oxygen and carbon nuclei in the reservoir rock. The first step of the invention is to record first and second logs sensitive to the abundance of oxygen and carbon nuclei, respectively, after the region surrounding the well bore is caused to have fluid saturations representative of the bulk of the reservoir. A purposeful change is then made in the fluid saturations in the region surrounding the well bore by injecting a liquid capable of displacing substantially all of the original fluids. The logs are recorded a second time. The displacing fluid is then itself displaced by brine, and a third suite of logs is recorded. The total fluid and oil saturations are then determined from the differences between respective corresponding logs and from known fractional volume oxygen and carbon contents of the reservoir brine and oil and the first injected liquid. Gas saturation is then calculated from differences between total fluid and oil saturation values. It is not necessary that the log responses be independent of the material in the borehole, the casing, the casing cement, or the reservoir rock. It is only necessary that changes in formation fluids content cause proportional changes in log responses. 7 Claims, 4 Figures

  5. Heart Rate and Oxygen Saturation Change Patterns During 6-min Walk Test in Subjects With Chronic Thromboembolic Pulmonary Hypertension.

    Science.gov (United States)

    Inagaki, Takeshi; Terada, Jiro; Yahaba, Misuzu; Kawata, Naoko; Jujo, Takayuki; Nagashima, Kengo; Sakao, Seiichiro; Tanabe, Nobuhiro; Tatsumi, Koichiro

    2017-12-26

    The 6-min walk test (6MWT) is commonly performed to assess functional status in patients with chronic thromboembolic pulmonary hypertension. However, changes in heart rate and oxygen saturation ( S pO 2 ) patterns during 6MWT in patients with chronic thromboembolic pulmonary hypertension remain unclear. Thirty-one subjects with chronic thromboembolic pulmonary hypertension were retrospectively evaluated to examine the relationships between the change in heart rate (Δheart rate), heart rate acceleration time, slope of heart rate acceleration, heart rate recovery during the first minute after 6MWT (HRR1), change in S pO 2 (Δ S pO 2 ), S pO 2 reduction time, and S pO 2 recovery time during 6MWT, and the severity of pulmonary hemodynamics assessed by right heart catheterization and echocardiography. Subjects with severe chronic thromboembolic pulmonary hypertension had significantly longer heart rate acceleration time (144.9 ± 63.9 s vs 96.0 ± 42.5 s, P = .033), lower Δheart rate (47.4 ± 16.9 vs 61.8 ± 13.6 beats, P = .02), and lower HRR1 (13.3 ± 9.0 beats vs 27.1 ± 9.2 beats, P pulmonary hypertension. Subjects with severe chronic thromboembolic pulmonary hypertension also had significantly longer S pO 2 reduction time (178.3 ± 70.3 s vs 134.3 ± 58.4 s, P = .03) and S pO 2 recovery time (107.6 ± 35.3 s vs 69.8 ± 32.7 s, P = .004) than did subjects with mild chronic thromboembolic pulmonary hypertension. Multivariate linear regression analysis showed only mean pulmonary arterial pressure independently was associated with heart rate acceleration time and slope of heart rate acceleration. Heart rate and S pO 2 change patterns during 6MWT is predominantly associated with pulmonary hemodynamics in subjects with chronic thromboembolic pulmonary hypertension. Evaluating heart rate and S pO 2 change patterns during 6MWT may serve a safe and convenient way to follow the change in pulmonary hemodynamics. Copyright © 2017 by Daedalus Enterprises.

  6. [Design of Oxygen Saturation, Heart Rate, Respiration Rate Detection System Based on Smartphone of Android Operating System].

    Science.gov (United States)

    Zhu, Mingshan; Zeng, Bixin

    2015-03-01

    In this paper, we designed an oxygen saturation, heart rate, respiration rate monitoring system based on smartphone of android operating system, physiological signal acquired by MSP430 microcontroller and transmitted by Bluetooth module.

  7. Growth of the microalgae Neochloris oleoabundans at high partial oxygen pressures and sub-saturating light intensity.

    Science.gov (United States)

    Sousa, Cláudia; de Winter, Lenneke; Janssen, Marcel; Vermuë, Marian H; Wijffels, René H

    2012-01-01

    The effect of partial oxygen pressure on growth of Neochloris oleoabundans was studied at sub-saturating light intensity in a fully-controlled stirred tank photobioreactor. At the three partial oxygen pressures tested (P(O)₂= 0.24; 0.63; 0.84 bar), the specific growth rate was 1.38; 1.36 and 1.06 day(-1), respectively. An increase of the P(CO)₂from 0.007 to 0.02 bar at P(O₂) of 0.84 bar resulted in an increase in the growth rate from 1.06 to 1.36 day(-1). These results confirm that the reduction of algal growth at high oxygen concentrations at sub-saturating light conditions is mainly caused by competitive inhibition of Rubisco. This negative effect on growth can be overcome by restoring the O(2)/CO(2) ratio by an increase in the partial carbon dioxide pressure. In comparison to general practice (P(O(2)) = 0.42 bar), working at partial O(2) pressure of 0.84 bar could reduce the energy requirement for degassing by a factor of 3-4. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Improved Apnea-Hypopnea Index and Lowest Oxygen Saturation After Maxillomandibular Advancement With or Without Counterclockwise Rotation in Patients With Obstructive Sleep Apnea

    DEFF Research Database (Denmark)

    Knudsen, Torben B.; Laulund, Anne Sofie; Ingerslev, Janne

    2015-01-01

    - and postsurgical values of pharyngeal volume measured on computed tomogram or cone-beam computed tomogram and changes in Apnea-Hypopnea Index (AHI) and lowest oxygen saturation (LSAT) values after surgery. Datawere subjected to a meta-analysis based on odds ratios (OR) with 95% confidence intervals (CIs) and P...... between pharyngeal volume changes and surgical method used. Postoperative parameters included an AHI lower than 5 (OR = 14.9; 95% CI, 2.7-83.5; P = .002), an AHI lower than 20 (OR = 114.8; 95% CI, 23.5-561.1; P

  9. Prognostic value of cerebral tissue oxygen saturation during neonatal extracorporeal membrane oxygenation.

    Directory of Open Access Journals (Sweden)

    Marie-Philippine Clair

    Full Text Available Extracorporeal membrane oxygenation support is indicated in severe and refractory respiratory or circulatory failures. Neurological complications are typically represented by acute ischemic or hemorrhagic lesions, which induce higher morbidity and mortality. The primary goal of this study was to assess the prognostic value of cerebral tissue oxygen saturation (StcO2 on mortality in neonates and young infants treated with ECMO. A secondary objective was to evaluate the association between StcO2 and the occurrence of cerebral lesions.This was a prospective study in infants < 3 months of age admitted to a pediatric intensive care unit and requiring ECMO support.The assessment of cerebral perfusion was made by continuous StcO2 monitoring using near-infrared spectroscopy (NIRS sensors placed on the two temporo-parietal regions. Neurological lesions were identified by MRI or transfontanellar echography.Thirty-four infants <3 months of age were included in the study over a period of 18 months. The ECMO duration was 10±7 days. The survival rate was 50% (17/34 patients, and the proportion of brain injuries was 20% (7/34 patients. The mean StcO2 during ECMO in the non-survivors was reduced in both hemispheres (p = 0.0008 right, p = 0.03 left compared to the survivors. StcO2 was also reduced in deceased or brain-injured patients compared to the survivors without brain injury (p = 0.002.StcO2 appears to be a strong prognostic factor of survival and of the presence of cerebral lesions in young infants during ECMO.

  10. T2-prepared velocity selective labelling : A novel idea for full-brain mapping of oxygen saturation

    NARCIS (Netherlands)

    Alderliesten, Thomas; De Vis, Jill B; Lemmers, Petra M A; van Bel, Frank; Benders, Manon J N L; Hendrikse, Jeroen; Petersen, Esben T

    2016-01-01

    BACKGROUND AND AIM: Disturbances in cerebral oxygenation saturation (SO2) have been linked to adverse outcome in adults, children, and neonates. In intensive care, the cerebral SO2 is increasingly being monitored by Near-InfraRed Spectroscopy (NIRS). Unfortunately NIRS has a limited penetration

  11. Carbon Dioxide Fluctuations Are Associated with Changes in Cerebral Oxygenation and Electrical Activity in Infants Born Preterm.

    Science.gov (United States)

    Dix, Laura Marie Louise; Weeke, Lauren Carleen; de Vries, Linda Simone; Groenendaal, Floris; Baerts, Willem; van Bel, Frank; Lemmers, Petra Maria Anna

    2017-08-01

    To evaluate the effects of acute arterial carbon dioxide partial pressure changes on cerebral oxygenation and electrical activity in infants born preterm. This retrospective observational study included ventilated infants born preterm with acute fluctuations of continuous end-tidal CO 2 (etCO 2 ) as a surrogate marker for arterial carbon dioxide partial pressure, during the first 72 hours of life. Regional cerebral oxygen saturation and fractional tissue oxygen extraction were monitored with near-infrared spectroscopy. Brain activity was monitored with 2-channel electroencephalography. Spontaneous activity transients (SATs) rate (SATs/minute) and interval between SATs (in seconds) were calculated. Ten-minute periods were selected for analysis: before, during, and after etCO 2 fluctuations of ≥5  mm Hg. Thirty-eight patients (mean ± SD gestational age of 29 ± 1.8 weeks) were included, with 60 episodes of etCO 2 increase and 70 episodes of etCO 2 decrease. During etCO 2 increases, brain oxygenation increased (regional cerebral oxygen saturation increased, fractional tissue oxygen extraction decreased; P carbon dioxide partial pressure that may be harmful to the neonatal brain. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. The Relationship between Oxygen Saturation and Color Alteration of a Compromised Skin Flap: Experimental Study on the Rabbit

    Directory of Open Access Journals (Sweden)

    Theddeus O. H. Prasetyono

    2013-09-01

    Full Text Available Background The aim of this study was to collect important data on the time of oxygensaturation change in relation to skin flap color alteration using non-invasive pulse oximetryto evaluate its ability to provide continuous monitoring of skin flap perfusion.Methods An experimental study on the monitoring of blood perfusion of 20 tube-islandgroin flaps of 10 male New Zealand rabbits was performed using pulse oximetry. The animalswere randomly assigned to one of two groups representing a blockage of either arterial orvenous blood flow. The oxygen saturation change and clinical color alteration were monitoredfrom the beginning of vessel clamping until the saturation became undetectable. The resultwas analyzed by the t-test using SSPS ver. 10.0.Results The mean times from the vessel clamping until the saturation became undetectablewere 20.19±2.13 seconds and 74.91±10.57 seconds for the artery and vein clamping groups,respectively. The mean time of the clinical alteration from the beginning of vein clampingwas 34.5±11.72 minutes, while the alteration in flaps with artery clamping could not bedetected until 2.5 hours after clamping.Conclusions The use of neonate-type reusable flex sensor-pulse oximetry is objective andeffective in early detection of arterial and vein blockage. It provides real-time data on vesselocclusion, which in turn will allow for early salvaging. The detection periods of both arterialocclusion and venous congestion are much earlier than the color alteration one may encounterclinically.

  13. A pilot study of a new spectrophotometry device to measure tissue oxygen saturation.

    Science.gov (United States)

    Abel, Gemma; Allen, John; Drinnan, Michael

    2014-09-01

    Tissue oxygen saturation (SO2) measurements have the potential for far wider use than at present but are limited by device availability and portability for many potential applications. A device based on a small, low-cost general-purpose spectrophotometer (the Harrison device) might facilitate wider use. The aim of this study was to compare the Harrison device with a commercial instrument, the LEA O2C.Measurements were carried out on the forearm and finger of 20 healthy volunteers, using a blood pressure cuff on the upper arm to induce different levels of oxygenation. Repeatability of both devices was assessed, and the Bland-Altman method was used to assess agreement between them.The devices showed agreement in overall tracking of changes in SO2. Test-retest agreement for the Harrison device was worse than for O2C, with SD repeatability of 10.6% (forearm) or 18.6% (finger). There was no overall bias between devices, but mean (SD) difference of 1.2 (11.8%) (forearm) or 4.4 (11.5%) (finger) were outside of a clinically acceptable range.Disagreements were attributed to the stability of the Harrison probe and the natural SO2 variations across the skin surface increasing the random error. Therefore, though not equivalent to the LEA O2C, a probe redesign and averaged measurements may help establish the Harrison device as a low cost alternative.

  14. A pilot study of a new spectrophotometry device to measure tissue oxygen saturation

    International Nuclear Information System (INIS)

    Abel, Gemma; Allen, John; Drinnan, Michael

    2014-01-01

    Tissue oxygen saturation (SO2) measurements have the potential for far wider use than at present but are limited by device availability and portability for many potential applications. A device based on a small, low-cost general-purpose spectrophotometer (the Harrison device) might facilitate wider use. The aim of this study was to compare the Harrison device with a commercial instrument, the LEA O2C. Measurements were carried out on the forearm and finger of 20 healthy volunteers, using a blood pressure cuff on the upper arm to induce different levels of oxygenation. Repeatability of both devices was assessed, and the Bland–Altman method was used to assess agreement between them. The devices showed agreement in overall tracking of changes in SO2. Test–retest agreement for the Harrison device was worse than for O2C, with SD repeatability of 10.6% (forearm) or 18.6% (finger). There was no overall bias between devices, but mean (SD) difference of 1.2 (11.8%) (forearm) or 4.4 (11.5%) (finger) were outside of a clinically acceptable range. Disagreements were attributed to the stability of the Harrison probe and the natural SO2 variations across the skin surface increasing the random error. Therefore, though not equivalent to the LEA O2C, a probe redesign and averaged measurements may help establish the Harrison device as a low cost alternative. (paper)

  15. Oxygen saturation index and severity of hypoxic respiratory failure.

    Science.gov (United States)

    Rawat, Munmun; Chandrasekharan, Praveen K; Williams, Ashley; Gugino, Sylvia; Koenigsknecht, Carmon; Swartz, Daniel; Ma, Chang Xing; Mathew, Bobby; Nair, Jayasree; Lakshminrusimha, Satyan

    2015-01-01

    The oxygenation index (OI = mean airway pressure, MAP × FiO2 × 100 : PaO2) is used to assess the severity of hypoxic respiratory failure (HRF) and persistent pulmonary hypertension of the newborn (PPHN). An indwelling arterial line or arterial punctures are necessary to obtain PaO2 for the calculation of OI. Oxygenation can be continuously and noninvasively assessed using pulse oximetry. The use of the oxygen saturation index (OSI = MAP × FiO2 × 100 : SpO2) can be an alternate method of assessing the severity of HRF. To evaluate the correlation between OSI and OI in the following: (1) neonates with HRF and (2) a lamb model of meconium aspiration syndrome. Human neonates: a retrospective chart review of 74 ventilated late preterm/term neonates with indwelling arterial access and SpO2 values in the first 24 h of life was conducted. OSI and OI were calculated and correlated. Lamb model: arterial blood gases were drawn and preductal SpO2 was documented in 40 term newborn lambs with asphyxia and meconium aspiration. OI and OSI were calculated and correlated with pulmonary vascular resistance (PVR). Mean values of OSI and OI showed a correlation coefficient of 0.952 in neonates (mean value of 308 observations in 74 neonates) and 0.948 in lambs (mean value of 743 observations in 40 lambs). In lambs, with increasing PVR, there was a decrease in OI and OSI. OSI correlates significantly with OI in infants with HRF. This noninvasive measure may be used to assess the severity of HRF and PPHN in neonates without arterial access. © 2015 S. Karger AG, Basel

  16. Decadal changes in the CaCO3 saturation state along 179°E in the Pacific Ocean

    Science.gov (United States)

    Murata, Akihiko; Saito, Shu

    2012-06-01

    To assess degrees of ocean acidification, we mainly investigated decadal changes in the saturation state of seawater with respect to aragonite (Ωarg), which is a more vulnerable mineral form of CaCO3, along the 179°E meridian (WOCE P14N) in the Pacific Ocean. We found a maximum decrease of Ωarg of -0.48 (-0.034 a-1) at 200-300 dbar (isopycnal surfaces of 24.0-25.8 kg m-3) at 20°N. Between 1993 and 2007, the saturation horizon rose by 17 dbar (1.2 dbar a-1) at latitudes 10°N-50°N. Although ΔΩarg mostly reflected changes in normalized dissolved inorganic carbon (ΔnCT), it was larger than could be explained by anthropogenic CO2 storage alone. Decomposition of ΔnCT revealed that ΔΩarg was enhanced by approximately 50% by a non-anthropogenic CO2 contribution represented by changes in apparent oxygen utilization. Our results suggest that ocean acidification can be temporarily accelerated by temporal changes in oceanic conditions.

  17. Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions.

    Science.gov (United States)

    Abay, T Y; Kyriacou, P A

    2018-06-01

    Photoplethysmography (PPG) is an optical technique that measures blood volume variations. The main application of dual-wavelength PPG is pulse oximetry, in which the arterial oxygen saturation (SpO[Formula: see text]) is calculated noninvasively. However, the PPG waveform contains other significant physiological information that can be used in conjunction to SpO[Formula: see text] for the assessment of oxygenation and blood volumes changes. This paper investigates the use of near infrared spectroscopy (NIRS) processing techniques for extracting relative concentration changes of oxygenated ([Formula: see text]HbO[Formula: see text]), reduced ([Formula: see text]HHb) and total haemoglobin ([Formula: see text]tHb) from dual-wavelength PPG signals during intermittent pressure-increasing vascular occlusions. A reflectance PPG sensor was attached on the left forearm of nineteen (n = 19) volunteers, along with a reference NIRS sensor positioned on the same forearm, above the left brachioradialis. The investigation protocol consisted of seven intermittent and pressure-increasing vascular occlusions. Relative changes in haemoglobin concentrations were obtained by applying the modified Beer-Lambert law to PPG signals, while oxygenation changes were estimated by the difference between red and infrared attenuations of DC PPGs (A[Formula: see text] = [Formula: see text]A[Formula: see text] - [Formula: see text]A[Formula: see text]) and by the conventional SpO[Formula: see text]. The [Formula: see text]HbO[Formula: see text], [Formula: see text]HHb, [Formula: see text]tHb from the PPG signals indicated significant changes in perfusion induced by either partial and complete occlusions (p < 0.05). The trends in the variables extracted from PPG showed good correlation with the same parameters measured by the reference NIRS monitor. Bland and Altman analysis of agreement between PPG and NIRS showed underestimation of the magnitude of changes by the PPG. A[Formula: see text

  18. The Effects of Massage with Coconut and Sunflower Oils on Oxygen Saturation of Premature Infants with Respiratory Distress Syndrome Treated With Nasal Continuous Positive Airway Pressure

    Directory of Open Access Journals (Sweden)

    Sousan Valizadeh

    2012-11-01

    Full Text Available Introduction: Nowadays particular emphasis is placed on the developmental aspects of premature infants care. Massage therapy is one of the best-known methods of caring. Due to the minimal touch policy in neonatal intensive care units (NICUs, massaging is not usually performed on premature infants. However, there is not sufficient evidence to support the claim that newborn infants with complex medical conditions should not be massaged. This study aimed to determine the effects of massage with coconut and sunflower oils on oxygen saturation of infants with respiratory distress syndrome (RDS treated with nasal continuous positive airway pressure (NCPAP. Methods: This was a randomized controlled trial on 90 newborns who were admitted to Alzahra Hospital (Tabriz, Iran. The infants were divided into control and massage therapy groups (massage with coconut and sunflower oils. Data was collected using a hospital documentation form. A 15-minute daily massage was performed for 3 days. Respiratory rate (RR, fraction of inspired oxygen (FiO2 and oxygen saturation were measured 5 minutes before the massage, 3 times during the massage, and 5 minutes after the massage. The collected data was analyzed using a mixed model. Results: In comparison to coconut oil and control groups, mean oxygen saturation of sunflower oil group was improved. In addition, the coconut massage group showed lower oxygen saturation than the control group but was all values were within the normal range. Although massage decreased oxygen saturation, there was no need to increase FiO2. Conclusion: Massage therapy can provide developmental care for infants treated with NCPAP.

  19. Comparison of emissions and performance between saturated cyclic oxygenates and aromatics in a heavy-duty diesel engine

    NARCIS (Netherlands)

    Zhou, L.; Boot, M.D.; Johansson, B.H.

    2013-01-01

    Emissions and fuel economy are evaluated for two types of biofuels, namely 2-phenyl ethanol and cyclohexaneethanol. Both are derived from lignin, a form of lignocellulosic biomass. The former and latter oxygenates have an aromatic and aliphatic (i.e. saturated) ring structure, respectively. Two

  20. Effects of targeting lower versus higher arterial oxygen saturations on death or disability in preterm infants.

    Science.gov (United States)

    Askie, Lisa M; Darlow, Brian A; Davis, Peter G; Finer, Neil; Stenson, Ben; Vento, Maximo; Whyte, Robin

    2017-04-11

    The use of supplemental oxygen in the care of extremely preterm infants has been common practice since the 1940s. Despite this, there is little agreement regarding which oxygen saturation (SpO₂) ranges to target to maximise short- or long-term growth and development, while minimising harms. There are two opposing concerns. Lower oxygen levels (targeting SpO₂ at 90% or less) may impair neurodevelopment or result in death. Higher oxygen levels (targeting SpO₂ greater than 90%) may increase severe retinopathy of prematurity or chronic lung disease.The use of pulse oximetry to non-invasively assess neonatal SpO₂ levels has been widespread since the 1990s. Until recently there were no randomised controlled trials (RCTs) that had assessed whether it is better to target higher or lower oxygen saturation levels in extremely preterm infants, from birth or soon thereafter. As a result, there is significant international practice variation and uncertainty remains as to the most appropriate range to target oxygen saturation levels in preterm and low birth weight infants. 1. What are the effects of targeting lower versus higher oxygen saturation ranges on death or major neonatal and infant morbidities, or both, in extremely preterm infants?2. Do these effects differ in different types of infants, including those born at a very early gestational age, or in those who are outborn, without antenatal corticosteroid coverage, of male sex, small for gestational age or of multiple birth, or by mode of delivery? We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL 2016, Issue 4), MEDLINE via PubMed (1966 to 11 April 2016), Embase (1980 to 11 April 2016) and CINAHL (1982 to 11 April 2016). We also searched clinical trials databases, conference proceedings and the reference lists of retrieved articles for randomised controlled trials. Randomised controlled trials that enrolled babies born at less than 28

  1. [Association between oxygen saturation and cognitive function in older adults from longevity areas in China].

    Science.gov (United States)

    Su, L Q; Yin, Z X; Xu, N; Lyu, Y B; Luo, J S; Shi, X M

    2016-07-06

    To explore the relationship between oxygen saturation (SpO2) and cognitive function in older adults from longevity areas in China. A total of 2 285 participants aged ≥65 years according to the 2012 Chinese Longitudinal Healthy Longevity Survey were included in this study. Among them, 1 739 participants aged 65-99 years were randomly selected, and 546 participants aged ≥100 years were totally involved. A standardized questionaire was used to collect the information of demographic characteristics, life styles, disease history, etc. Cognitive function was evaluated using the Mini Mental State Examination Scale. Arterial oxygen saturation and heart rate were measured by pulse oximetry. Differences in cognitive function between the low SpO2 group (cognitive function. The total score of cognitive function was 22.6±9.7 for the 1 922 participants in the normal SpO2 group, and 18.8 ± 11.0 for the 363 participants in the low SpO2 group (t=6.11, Pcognitive impairment in the low SpO2 group was 36.6% (n=133), and 22.9% (n=441) in the normal SpO2 group (χ(2)=30.44, Pcognitive impairment increased with each year of increased age (OR 1.07; (95% CI: 1.05-1.09), Pcognitive impairment (OR 1.64; (95% CI: 1.11-2.43), OR 1.73; (95% CI: 1.27-2.35), OR 3.54; (95% CI: 2.62-4.79), OR 1.38; (95% CI: 1.02-1.86), OR 2.05; (95% CI: 1.34-3.13), OR 1.83; (95% CI: 1.13-2.97), respectively, Page group showed that the association between SpO2 and cognitive impairment was most significant in participants aged ≥90 years (OR 1.58; (95% CI: 1.09-2.28), P=0.016). Low oxygen saturation was associated with higher risk of cognitive impairment in our population of elderly adults.

  2. Mental abilities and performance efficacy under a simulated 480 meters helium-oxygen saturation diving

    Directory of Open Access Journals (Sweden)

    gonglin ehou

    2015-07-01

    Full Text Available Stress in extreme environment severely disrupts human physiology and mental abilities. The present study investigated the cognition and performance efficacy of four divers during a simulated 480 meters helium-oxygen saturation diving. We analyzed the spatial memory, 2D/3D mental rotation functioning, grip strength, and hand-eye coordination ability in four divers during the 0 – 480 meters compression and decompression processes of the simulated diving. The results showed that except for its mild decrease on grip strength, the high atmosphere pressure condition significantly impaired the hand-eye coordination (especially at 300 meters, the reaction time and correct rate of mental rotation, as well as the spatial memory (especially as 410 meters, showing high individual variability. We conclude that the human cognition and performance efficacy are significantly affected during deep water saturation diving.

  3. RAPID COMMUNICATION: A novel time frequency-based 3D Lissajous figure method and its application to the determination of oxygen saturation from the photoplethysmogram

    Science.gov (United States)

    Addison, Paul S.; Watson, James N.

    2004-11-01

    We present a novel time-frequency method for the measurement of oxygen saturation using the photoplethysmogram (PPG) signals from a standard pulse oximeter machine. The method utilizes the time-frequency transformation of the red and infrared PPGs to derive a 3D Lissajous figure. By selecting the optimal Lissajous, the method provides an inherently robust basis for the determination of oxygen saturation as regions of the time-frequency plane where high- and low-frequency signal artefacts are to be found are automatically avoided.

  4. Photoacoustic measurements of red blood cell oxygen saturation in blood bags in situ

    Science.gov (United States)

    Pinto, Ruben N.; Bagga, Karan; Douplik, Alexandre; Acker, Jason P.; Kolios, Michael C.

    2017-03-01

    Red blood cell (RBC) transfusion is a critical component of the health care services. RBCs are stored in blood bags in hypothermic temperatures for a maximum of 6 weeks post donation. During this in vitro storage period, RBCs have been documented to undergo changes in structure and function due to mechanical and biochemical stress. Currently, there are no assessment methods that monitor the quality of RBCs within blood bags stored for transfusion. Conventional assessment methods require the extraction of samples, consequently voiding the sterility of the blood bags and potentially rendering them unfit for transfusions. It is hypothesized that photoacoustic (PA) technology can provide a rapid and non-invasive indication of RBC quality. In this study, a novel PA setup was developed for the acquisition of oxygen saturation (SO2) of two blood bags in situ. These measurements were taken throughout the lifespan of the blood bags (42 days) and compared against the clinical gold standard method of the blood gas analyzer (BGA). SO2 values of the blood bags increased monotonically throughout the storage period. A strong correlation between PA SO2 and BGA SO2 was found, however, PA values were on average 3.5% lower. Both techniques found the bags to increase by an SO2 of approximately 20%, and measured very similar rates of SO2 change. Future work will be focused on determining the cause of discrepancy between SO2 values acquired from PA versus BGA, as well as establishing links between the measured SO2 increase and other changes in RBC in situ.

  5. Reduced deep regional cerebral venous oxygen saturation in hemodialysis patients using quantitative susceptibility mapping.

    Science.gov (United States)

    Chai, Chao; Liu, Saifeng; Fan, Linlin; Liu, Lei; Li, Jinping; Zuo, Chao; Qian, Tianyi; Haacke, E Mark; Shen, Wen; Xia, Shuang

    2018-02-01

    Cerebral venous oxygen saturation (SvO 2 ) is an important indicator of brain function. There was debate about lower cerebral oxygen metabolism in hemodialysis patients and there were no reports about the changes of deep regional cerebral SvO 2 in hemodialysis patients. In this study, we aim to explore the deep regional cerebral SvO 2 from straight sinus using quantitative susceptibility mapping (QSM) and the correlation with clinical risk factors and neuropsychiatric testing . 52 hemodialysis patients and 54 age-and gender-matched healthy controls were enrolled. QSM reconstructed from original phase data of 3.0 T susceptibility-weighted imaging was used to measure the susceptibility of straight sinus. The susceptibility was used to calculate the deep regional cerebral SvO 2 and compare with healthy individuals. Correlation analysis was performed to investigate the correlation between deep regional cerebral SvO 2 , clinical risk factors and neuropsychiatric testing. The deep regional cerebral SvO 2 of hemodialysis patients (72.5 ± 3.7%) was significantly lower than healthy controls (76.0 ± 2.1%) (P deep regional cerebral SvO 2 in patients. The Mini-Mental State Examination (MMSE) scores of hemodialysis patients were significantly lower than healthy controls (P deep regional cerebral SvO 2 did not correlate with MMSE scores (P = 0.630). In summary, the decreased deep regional cerebral SvO 2 occurred in hemodialysis patients and dialysis duration, parathyroid hormone, hematocrit, hemoglobin and red blood cell may be clinical risk factors.

  6. Cerebral time domain-NIRS: Reproducibility analysis, optical properties, hemoglobin species and tissue oxygen saturation in a cohort of adult subjects

    OpenAIRE

    Giacalone, Giacomo; Zanoletti, Marta; Contini, Davide; Rebecca, Re; Spinelli, Lorenzo; Roveri, Luisa; Torricelli, Alessandro

    2017-01-01

    The reproducibility of cerebral time-domain near-infrared spectroscopy (TD-NIRS) has not been investigated so far. Besides, reference intervals of cerebral optical properties, of absolute concentrations of deoxygenated-hemoglobin (HbR), oxygenated-hemoglobin (HbO), total hemoglobin (HbT) and tissue oxygen saturation (StO2) and their variability have not been reported. We have addressed these issues on a sample of 88 adult healthy subjects. TD-NIRS measurements at 690, 785, 830 nm were fitted ...

  7. In-vivo continuous monitoring of mixed venous oxygen saturation by photoacoustic transesophageal echocardiography (Conference Presentation)

    Science.gov (United States)

    Li, Li; Subramaniam, Balachundhar; Aguirre, Aaron D.; Andrawes, Michael N.; Tearney, Guillermo J.

    2016-02-01

    Mixed venous oxygen saturation (SvO2), measured from pulmonary arteries, is a gold-standard measure of the dynamic balance between the oxygen supply and demand in the body. In critical care, continuous monitoring of SvO2 plays a vital role in early detection of circulatory shock and guiding goal-oriented resuscitation. In current clinical practice, SvO2 is measured by invasive pulmonary artery catheters (PAC), which are associated with a 10% risk of severe complications. To address the unmet clinical need for a non-invasive SvO2 monitor, we are developing a new technology termed photoacoustic transesophageal echocardiography (PA-TEE). PA-TEE integrates transesophageal echocardiography with photoacoustic oximetry, and enables continuous assessment of SvO2 through an esophageal probe that can be inserted into the body in a minimally invasive manner. We have constructed a clinically translatable PA-TEE prototype, which features a mobile OPO laser, a modified ultrasonography console and a dual-modality esophageal probe. Comprised of a rotatable acoustic array detector, a flexible optical fiber bundle and a light-integrating acoustic lens, the oximetric probe has an outer diameter smaller than 15 mm and will be tolerable for most patients. Through custom-made C++/Qt software, our device acquires and displays ultrasonic and photoacoustic images in real time to guide the deployment of the probe. SvO2 is calculated on-line and updated every second. PA-TEE has now been used to evaluate SvO2 in living swine. Our findings show that changing the fraction of oxygen in the inspired gas modulates SvO2 measured by PA-TEE. Statistic comparison between SvO2 measurements from PA-TEE in vivo the gold-standard laboratorial analysis on blood samples drawn from PACs will be presented.

  8. Changes in Oxygen Partial Pressure in the Vitreous Body and Arterial Blood of Rabbits Depending on Oxygen Concentration in Inspired Mixture.

    Science.gov (United States)

    Amkhanitskaya, L I; Nikolaeva, G V; Sokolova, N A

    2015-07-01

    We demonstrated that the vitreous body of one-month-old rabbits becomes a "reservoir" for storage and accumulation of oxygen after exposure to additional oxygenation of the organism (O2 concentrations in inspired gas mixture were 40, 60, 85, and 99%). The higher was O2 concentration in inspired mixture, the higher was oxygen saturation of the blood and vitreous body. O2 concentration of 40% was relatively safe for eye tissues. O2 concentration >60% induced oxygen accumulation in the vitreous body, which can be a provoking factor for the development of oxygen-induced pathologies.

  9. Blood gases and oxygen saturation response to active cycle of breathing techniques in COPD patients during phase I of cardiac rehabilitation

    International Nuclear Information System (INIS)

    Sheraz, S.; Siddiqi, F.A.

    2015-01-01

    Objective: To determine the effectiveness of active cycle of breathing techniques (ACBTs) on arterial blood gases (ABG), oxygen saturation and other vitals including chest expansion, heart rate, and respiratory rate in COPD patients during phase I of cardiac rehabilitation program after open heart surgery. Methodology: In this experimental study, sample size chosen was 100 patients, randomly divided into experimental (n=50) and control (n=50) groups. Pre-test values of ABG, oxygen saturation, chest expansion, respiratory rate, and heart rate of the participants were taken. Then, conventional physical therapy including spirometry was performed 2 hourly by the control group whereas the experimental group performed ACBTs along with spirometry twice a day for a period of one week. Participants were re-assessed after one week treatment. Results: There was highly significant difference (p<0.01) in pre-test and post-test values of PCO/sub 2/ and oxygen saturation in experimental group as compared to control group. The results of bicarbonate values, base excess and heart rate were statistically significant (p<0.01) in control group and there was no significant difference (p>0.05) in experimental group. The values of pH, chest expansion and respiratory rate were highly significant (p<0.01) in both control as well as experimental group. Conclusion: ACBT was more effective to decrease post CABG complication as compared to conventional chest physical therapy. Some parameters like bicarbonate values, base excess and heart rate did not show improvement with ACBT. (author)

  10. Skeletal Muscle Oxygen Saturation (StO2 Measured by Near-Infrared Spectroscopy in the Critically Ill Patients

    Directory of Open Access Journals (Sweden)

    J. Mesquida

    2013-01-01

    Full Text Available According to current critical care management guidelines, the overall hemodynamic optimization process seeks to restore macrocirculatory oxygenation, pressure, and flow variables. However, there is increasing evidence demonstrating that, despite normalization of these global parameters, microcirculatory and regional perfusion alterations might occur, and persistence of these alterations has been associated with worse prognosis. Such observations have led to great interest in testing new technologies capable of evaluating the microcirculation. Near-infrared spectroscopy (NIRS measures tissue oxygen saturation (StO2 and has been proposed as a noninvasive system for monitoring regional circulation. The present review aims to summarize the existing evidence on NIRS and its potential clinical utility in different scenarios of critically ill patients.

  11. Evaluation of arterial oxygen saturation using RGB camera-based remote photoplethysmography

    Science.gov (United States)

    Nishidate, Izumi; Nakano, Kazuya; McDuff, Daniel; Niizeki, Kyuichi; Aizu, Yoshihisa; Haneishi, Hideaki

    2018-02-01

    Plethysmogram is the periodic variation in blood volume due to the cardiac pulse traveling through the body. Photo-plethysmograph (PPG) has been widely used to assess the cardiovascular system such as heart rate, blood pressure, cardiac output, vascular compliance. We have previously proposed a non-contact PPG imaging method using a digital red-green-blue camera. In the method, the Monte Carlo simulation for light transport is used to specify a relationship among the RGB-values and the concentrations of oxygenated hemoglobin (CHbO) and deoxygenated hemoglobin (CHbR). The total hemoglobin concentration (CHbT) can be calculated as a sum of CHbO and CHbR. Applying the fast Fourier transform (FFT) band pass filters to each pixel of the sequential images for CHbT along the time line, two-dimentional plethysmogram can be reconstructed. In this study, we further extend the method to imaging the arterial oxygen saturation (SaO2). The PPG signals for both CHbO and CHbR are extracted by the FFT band pass filter and the pulse wave amplitudes (PWAs) of CHbO and CHbR are calculated. We assume that the PWA for CHbO and that for CHbR are decreased and increased as SaO2 is decreased. The ratio of PWA for CHbO and that for CHbR are associated to the reference value of SaO2 measured by a commercially available pulse oximeter, which provide an empirical formula to estimate SaO2 from the PPG signal at each pixel of RGB image. In vivo animal experiments with rats during varying the fraction of inspired oxygen (FiO2) demonstrated the feasibility of the proposed method.

  12. Independent component analysis applied to pulse oximetry in the estimation of the arterial oxygen saturation (SpO2) - a comparative study

    DEFF Research Database (Denmark)

    Jensen, Thomas; Duun, Sune Bro; Larsen, Jan

    2009-01-01

    We examine various independent component analysis (ICA) digital signal processing algorithms for estimating the arterial oxygen saturation (SpO2) as measured by a reflective pulse oximeter. The ICA algorithms examined are FastICA, Maximum Likelihood ICA (ICAML), Molgedey and Schuster ICA (ICAMS......), and Mean Field ICA (ICAMF). The signal processing includes pre-processing bandpass filtering to eliminate noise, and post-processing by calculating the SpO2. The algorithms are compared to the commercial state-of-the-art algorithm Discrete Saturation Transform (DST) by Masimo Corporation...

  13. Assessment of Arterial Oxygen Saturation by Pulse Oximetry Before, During and After Electroconvulsive Therapy

    Directory of Open Access Journals (Sweden)

    SH Tarig

    2006-07-01

    Full Text Available Introduction & Objective: Electroconvulsive therapy (ECT is used widely in psychiatric practice. The goal of anesthesia for ECT is the prevention of complications such as discomfort, fractures, aspiration of gastric contents and hypoxia. However, general anesthesia can cause some adverse effects as hypoxia. Prevention and treatment of hypoxia is important due to its undesirable effects on seizure duration and cardiovascular system. This study was designed to detect the incidence and probable times of desaturation in patients receiving ECT. Materials & Methods: This prospective randomized clinical trial was carried out on 100 patients (18-50 y/o with ASA I or II who were scheduled for ECT. After pre-oxygenation and similar anesthesia induction the patients received ECT. The patients were ventilated by oxygen and face masked until the return of their spontaneous respiration with adequate tidal volume and respiratory rate. Then they were transferred to recovery room where there was no oxygen supplementation. Oxygen saturation was measured by a Nell core pulse oximeter and was recorded at six stages: before and after anesthesia induction, during ECT, after ECT, 5 minutes after entering recovery room and before leaving there. The data were analyzed by standard statistical tests using SPSS software Results: Data analysis revealed that desaturation was not noticed at any stage except for the 5th stage (5 minutes after entering recovery room, when 13% of patients developed Sao2% less than 90%. Also there was a significant difference between Sao2% of patients between this stage (5th and other stages (p<0.001. Conclusion: According to our findings, appropriate oxygen supplementation and pulse oximetry monitoring during recovery period after ECT can be recommend

  14. Assessment of tissue oxygen saturation during a vascular occlusion test using near-infrared spectroscopy: the role of probe spacing and measurement site studied in healthy volunteers

    NARCIS (Netherlands)

    Bezemer, R.; Lima, A.; Myers, D.; Klijn, E.; Heger, M.; Goedhart, P.T.; Bakker, J.; Ince, C.

    2009-01-01

    INTRODUCTION: To assess potential metabolic and microcirculatory alterations in critically ill patients, near-infrared spectroscopy (NIRS) has been used, in combination with a vascular occlusion test (VOT), for the non-invasive measurement of tissue oxygen saturation (StO2), oxygen consumption, and

  15. Serum albumin--a non-saturable carrier

    DEFF Research Database (Denmark)

    Brodersen, R; Honoré, B; Larsen, F G

    1984-01-01

    The shape of binding isotherms for sixteen ligands to human serum albumin showed no signs of approaching saturation at high ligand concentrations. It is suggested that ligand binding to serum albumin is essentially different from saturable binding of substrates to enzymes, of oxygen to haemoglobi...

  16. Investigation of spatial resolution dependent variability in transcutaneous oxygen saturation using point spectroscopy system

    Science.gov (United States)

    Philimon, Sheena P.; Huong, Audrey K. C.; Ngu, Xavier T. I.

    2017-08-01

    This paper aims to investigate the variation in one’s percent mean transcutaneous oxygen saturation (StO2) with differences in spatial resolution of data. This work required the knowledge of extinction coefficient of hemoglobin derivatives in the wavelength range of 520 - 600 nm to solve for the StO2 value via an iterative fitting procedure. A pilot study was conducted on three healthy subjects with spectroscopic data collected from their right index finger at different arbitrarily selected distances. The StO2 value estimated by Extended Modified Lambert Beer (EMLB) model revealed a higher mean StO2 of 91.1 ± 1.3% at a proximity distance of 30 mm compared to 60.83 ± 2.8% at 200 mm. The results showed a high correlation between data spatial resolution and StO2 value, and revealed a decrease in StO2 value as the sampling distance increased. The preliminary findings from this study contribute to the knowledge of the appropriate distance range for consistent and high repeatability measurement of skin oxygenation.

  17. Nanoparticle-enhanced spectral photoacoustic tomography: effect of oxygen saturation and tissue heterogeneity

    Science.gov (United States)

    Vogt, William C.; Jia, Congxian; Wear, Keith A.; Garra, Brian S.; Pfefer, T. Joshua

    2016-03-01

    Molecular imaging for breast cancer detection, infectious disease diagnostics and preclinical animal research may be achievable through combined use of targeted exogenous agents - such as nanoparticles - and spectral Photoacoustic Tomography (PAT). However, tissue heterogeneity can alter fluence distributions and acoustic propagation, corrupting measured PAT absorption spectra and complicating in vivo nanoparticle detection and quantitation. Highly absorptive vascular structures represent a common confounding factor, and variations in vessel hemoglobin saturation (SO2) may alter spectral content of signals from adjacent/deeper regions. To evaluate the impact of this effect on PAT nanoparticle detectability, we constructed heterogeneous phantoms with well-characterized channel-inclusion geometries and biologically relevant optical and acoustic properties. Phantoms contained an array of tubes at several depths filled with hemoglobin solutions doped with varying concentrations of gold nanorods with an absorption peak at 780 nm. Both overlying and target network SO2 was tuned using sodium dithionite. Phantoms were imaged from 700 to 900 nm using a custom PAT system comprised of a tunable pulsed laser and a research-grade ultrasound system. Recovered nanoparticle spectra were analyzed and compared with results from both spectrophotometry and PAT data from waterimmersed tubes containing blood and nanoparticle solutions. Results suggested that nanoparticle selection for a given PAT application should take into account expected oxygenation states of both target blood vessel and background tissue oxygenation to achieve optimal performance.

  18. EFFECTIVENESS OF AUTOGENIC DRAINAGE VERSUS POSTURAL DRAINAGE ON OXYGEN SATURATION IN PATIENTS WITH CHRONIC BRONCHITIS WITH 15 MINUTES POST THERAPY

    Directory of Open Access Journals (Sweden)

    V. Kiran

    2014-12-01

    Full Text Available Background: Patients with COPD will have more amount of secretions. To clear the secretions by using of different bronchial hygiene techniques like postural drainage and autogenic drainage technique, manual hyperventilation technique ,active cycle breathing technique .Hence in this study to compare the short-term effects of postural drainage with clapping (PD and autogenic drainage (AD on level of oxygen saturation in blood, and amount of sputum recovery. Methodology: The study was done on 60 patients with COPD. Dividing Patients into two group and patients were treated with PD or AD in separate Groups. The effectiveness of the treatment was measured up to 6 days. Pulse oximetry was monitored and sputum was collected immediately after treatment and 15 minutes following each treatment. Results: The results of the study shown that there was significant difference in the amount of sputum recovered with AD (14.0±3.5 g vs PD (24.4±3.0 g and significant differences in Oxygen saturation; during PD fell from 93.3±0.7% to 91.2±0.8% (p<0.01 and required 15 min following treatment to return to baseline. Oxygen saturation did not fall during AD and increased to gradually following complete treatment days (baseline, 93.3±0.8%; p<0.01. Conclusion: Hence this study concludes that Autogenic drainage is more effective in improving spo2 in COPD & does not cause a sudden fall in spo2 as occurs in Postural drainage immediately after therapy. And it can be better tolerated by patients with COPD while producing fewer benefits in sputum clearance. In concern to mean amount of secretion removal Postural is found to be more effective

  19. High-affinity hemoglobin and blood oxygen saturation in diving emperor penguins.

    Science.gov (United States)

    Meir, Jessica U; Ponganis, Paul J

    2009-10-01

    The emperor penguin (Aptenodytes forsteri) thrives in the Antarctic underwater environment, diving to depths greater than 500 m and for durations longer than 23 min. To examine mechanisms underlying the exceptional diving ability of this species and further describe blood oxygen (O2) transport and depletion while diving, we characterized the O2-hemoglobin (Hb) dissociation curve of the emperor penguin in whole blood. This allowed us to (1) investigate the biochemical adaptation of Hb in this species, and (2) address blood O2 depletion during diving, by applying the dissociation curve to previously collected partial pressure of O2 (PO2) profiles to estimate in vivo Hb saturation (SO2) changes during dives. This investigation revealed enhanced Hb-O2 affinity (P50=28 mmHg, pH 7.5) in the emperor penguin, similar to high-altitude birds and other penguin species. This allows for increased O2 at low blood PO2 levels during diving and more complete depletion of the respiratory O2 store. SO2 profiles during diving demonstrated that arterial SO2 levels are maintained near 100% throughout much of the dive, not decreasing significantly until the final ascent phase. End-of-dive venous SO2 values were widely distributed and optimization of the venous blood O2 store resulted from arterialization and near complete depletion of venous blood O2 during longer dives. The estimated contribution of the blood O2 store to diving metabolic rate was low and highly variable. This pattern is due, in part, to the influx of O2 from the lungs into the blood during diving, and variable rates of tissue O2 uptake.

  20. Oxygen therapy reduces postoperative tachycardia

    DEFF Research Database (Denmark)

    Stausholm, K; Kehlet, H; Rosenberg, J

    1995-01-01

    Concomitant hypoxaemia and tachycardia in the postoperative period is unfavourable for the myocardium. Since hypoxaemia per se may be involved in the pathogenesis of postoperative tachycardia, we have studied the effect of oxygen therapy on tachycardia in 12 patients randomly allocated to blinded...... air or oxygen by facemask on the second or third day after major surgery. Inclusion criteria were arterial hypoxaemia (oxygen saturation 90 beat.min-1). Each patient responded similarly to oxygen therapy: an increase in arterial oxygen saturation and a decrease...... in heart rate (p oxygen has a positive effect on the cardiac oxygen delivery and demand balance....

  1. Effects of blood transfusion on oxygen extraction ratio and central venous saturation in children after cardiac surgery.

    Science.gov (United States)

    Nasser, Bana; Tageldein, Mohmad; AlMesned, Abdulrahman; Kabbani, Mohammad

    2017-01-01

    Red blood cell transfusion is common in critically ill children after cardiac surgery. Since the threshold for hemoglobin (Hb) transfusion need is not well defined, the threshold Hb level at which dependent critical oxygen uptake-to-delivery (VO2-DO2) status compensation is uncertain. To assess the effects of blood transfusion on the oxygen extraction ratio (O2ER) and central venous oxygen saturation (ScvO2) to identify a critical O2ER value that could help us determine the critical need for blood transfusion. Prospective, observational cohort study. Cardiac Surgical Intensive Care Unit at Prince Sultan Cardiac Center in Qassim, Saudi Arabia. Between January 2013 and December 2015, we included all children with cardiac disease who underwent surgery and needed a blood transfusion. Demographic and laboratory data with physiological parameters before and 1 and 6 hours after transfusion were recorded and O2ER before and 6 hours after transfusion was computed. Cases were divided into two groups based on O2ER: Patients with increased O2ER (O2ER > 40%) and normal patients without increased O2ER (O2ER transfusion. Changes in O2ER and ScvO2 following blood transfusion. Of 103 patients who had blood transfusion, 75 cases had normal O2ER before transfusion while 28 cases had increased O2ER before transfusion. Following blood transfusion, O2ER and ScvO2 improved in the group that had increased O2ER before transfusion, but not in the group that had normal O2ER before transfusion. The clinical and hemodynamic indicators O2ER and ScvO2 may be considered as markers that can indicate a need for blood transfusion. The limitation of this study is the small number of patients that had increased O2ER before transfusion. There were few available variables to assess oxygen consumption.

  2. Characterization of hemodynamics and oxygenation in the renal cortex of rats

    Science.gov (United States)

    Grosenick, Dirk; Wabnitz, Heidrun; Macdonald, Rainer; Niendorf, Thoralf; Cantow, Kathleen; Flemming, Bert; Arakelyan, Karen; Seeliger, Erdmann

    2015-03-01

    We have performed a pre-clinical study on 13 rats to investigate the potential of near-infrared spectroscopy for quantification of hemoglobin concentration and oxygen saturation of hemoglobin in the renal cortex of small animals. These measurements were combined with laser-Doppler fluxmetry and a fluorescence quenching technique for quantification of tissue oxygen tension. Hemoglobin concentration and oxygen saturation were determined from experimental data by a Monte Carlo model. The methods were applied to investigate and compare temporal changes during several types of interventions such as arterial and venous occlusions, as well as hyperoxia, hypoxia and hypercapnia induced by different mixtures of the inspired gas.

  3. Effects of salmeterol on sleeping oxygen saturation in chronic obstructive pulmonary disease.

    LENUS (Irish Health Repository)

    Ryan, Silke

    2012-02-01

    BACKGROUND: Sleep is associated with important adverse effects in patients with chronic obstructive pulmonary disease (COPD), such as disturbed sleep quality and gas exchange, including hypoxemia and hypercapnia. The effects of inhaled long-acting beta(2)-agonist therapy (LABA) on these disturbances are unclear. OBJECTIVES: The aim of the study was to assess the effect of inhaled salmeterol on nocturnal sleeping arterial oxygen saturation (SaO(2)) and sleep quality. METHODS: In a randomized, double-blind, placebo-controlled, crossover study of moderate\\/severe stable COPD patients, we compared the effects of 4 weeks of treatment with salmeterol 50 microg b.d. and matching placebo on sleeping SaO(2) and sleep quality. Overnight polysomnography (PSG) was performed at baseline, and after 4 and 8 weeks in addition to detailed pulmonary function testing. Of 15 patients included, 12 completed the trial (median age 69 years, forced expiratory volume in 1 s, FEV(1): 39%). RESULTS: Both mean SaO(2) [salmeterol vs. placebo: 92.9% (91.2, 94.7) vs. 91.0% (88.9, 94.8); p = 0.016] and the percentage of sleep spent below 90% of SaO(2) [1.8% (0.0, 10.8) vs. 25.6% (0.5, 53.5); p = 0.005] improved significantly with salmeterol. Sleep quality was similar with both salmeterol and placebo on PSG. Static lung volumes, particularly trapped gas volume, tended to improve with salmeterol. CONCLUSION: We conclude that inhaled LABA therapy improves sleeping SaO(2) without significant change in sleep quality.

  4. THERMAL AND OXYGEN CONDITIONS IN CARP PONDS DURING THE SUMMER PERIOD

    Directory of Open Access Journals (Sweden)

    Magdalena Wiśnios

    2015-11-01

    Full Text Available The work presents changes of oxygen indices in carp ponds during the summer season. The basis of the research were regular water tests conducted in two ponds: Mydlniki II intended for carp farming in the second year of fish production cycle and Bocian used for carp farming in the third (final year of breeding. The temperature of pond water in July and August was optimal for development and farming of cyprinid fish and ranged from 16.6 to 30.5 °C. The lowest value of oxygen dissolved in water (6.4 mg·dm-3 was registered in Mydlniki II pond and was higher than the oxygen optimum for carp (5 mg·dm-3. Oxygen saturation in water of fish ponds exceeded the optimum upper limit value (168% on a few dates, however, it posed no lethal threat for fish. In August in Bocian pond oxygen saturation fell within the range of optimal values, creating better conditions for fish development. In the secondary pond (Mydlniki II it was found that oxygen saturation in water on 12 dates was lower than the low optimal value (96%.

  5. Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers

    International Nuclear Information System (INIS)

    Shafique, M; Kyriacou, P A

    2012-01-01

    Pulse oximetry utilizes the technique of photoplethysmography to estimate arterial oxygen saturation (SpO 2 ) values. During hypothermia, the amplitude of the photoplethysmograph (PPG) is compromised which can lead to inaccurate estimation of SpO 2 . A new mutlimode PPG/pulse oximeter sensor was developed to investigate the behaviour of PPGs during conditions of induced hypothermia (hand immersed in an ice bath). PPG measurements from 20 volunteers were conducted and SpO 2 values were estimated at all stages of the experiment. Good quality PPG signals were observed from the majority of the volunteers at almost all hand temperatures. At low temperature ranges, from 13 to 21 °C, the failure rate to estimate SpO 2 values from the multimode transreflectance PPG sensor was 2.4% as compared to the commercial pulse oximeter with a failure rate of 70%. (paper)

  6. Optical noninvasive calculation of hemoglobin components concentrations and fractional oxygen saturation using a ring-scattering pulse oximeter

    Science.gov (United States)

    Abdallah, Omar; Stork, Wilhelm; Muller-Glaser, Klaus

    2004-06-01

    The deficiencies of the currently used pulse oximeter are discussed in diverse literature. A hazardous pitfalls of this method is that the pulse oximeter will not detect carboxyhemoglobin (COHb) and methemoglobin (metHb) concentrations. This leads to incorrect measurement of oxygen saturation by carbon monoxide poisoning and methemoglobinemia. Also the total hemoglobin concentration will not be considered and can only be measured in-vitro up to now. A second pitfall of the standard pulse oximetry is that it will not be able to show a result by low perfusion of tissues. This case is available inter alia when the patient is under shock or has a low blood pressure. The new non-invasive system we designed measures the actual (fractional) oxygen saturation and hemoglobin concentration. It will enable us also to measure COHb and metHb. The measurement can be applied at better perfused body central parts. Four or more light emitting diodes (LEDs) or laser diodes (LDs) and five photodiodes (PDs) are used. The reflected light signal detected by photodiodes is processed using a modified Lambert-Beer law (I=I0×e-α.d ). According to this law, when a non scattering probe is irradiated with light having the incident intensity I0, the intensity of transmitted light I decays exponentially with the absorption coefficient a of that probe and its thickness d. Modifications of this law have been performed following the theoretical developed models in literature, Monte Carlo simulation and experimental measurement.

  7. The 30-second rule: the effects of prolonged intubation attempts on oxygen saturation and heart rate in preterm infants in the delivery room.

    Science.gov (United States)

    Wozniak, Madeline; Arnell, Kathy; Brown, Melissa; Gonzales, Sarah; Lazarus, Danielle; Rich, Wade; Katheria, Anup

    2018-04-01

    A duration of 30 seconds has been shown to improve the success rate of intubation attempts without any decompensation. There is limited data regarding the detrimental effects of prolonged intubation attempts in preterm infants. The aim was to determine the effect of prolonged intubation attempts on heart rate and oxygen saturation in preterm infants. We retrospectively reviewed videos and physiologic data collected during delivery room (DR) resuscitations. Infants who had a functioning pulse oximeter at the time of intubation in the delivery room were analyzed using video and analog recordings. The duration of the intubation attempt was defined as the time the laryngoscope blade was in the infant's mouth. Prolonged intubations were defined as intubations over 30 seconds. Baseline heart rate and saturations were defined as the heart rate and saturation immediately prior to the intubation attempt. Video recording was used to determine time laryngoscope was in the mouth, what other procedures were performed, and whether there was recovery between attempts. Analog data including heart rate, airway pressure and saturation was also recorded. There were 52 intubation attempts in 28 infants. The median (IQR) birth weight and gestational age were 795 (705, 972) grams and 25 (25, 27) weeks. The duration of an intubation attempt was 35 (27, 46) seconds with number of attempts 2 (1, 2). There were 34 intubation attempts greater than 30 seconds (prolonged group) and 18 attempts less than or equal to 30 seconds (short group). Longer attempts did not affect intubation success (successful 34 [25,37] seconds vs. unsuccessful 41[29, 53] seconds; P=0.05). Infants in the prolonged group had a greater decrease in oxygen saturation percentage from baseline (5±8 percent, short intubation group and 13±27 prolonged intubation group; P=0.004). There was also a significant decrease in heart rate beats per minute between the two groups (6±9 in the short intubation group and 23±29

  8. Stable isotopes of authigenic minerals in variably-saturated fractured tuff

    International Nuclear Information System (INIS)

    Weber, D.S.; Evans, D.D.

    1988-11-01

    Identifying stable isotope variation and mineralogical changes in fractured rock may help establish the history of climatic and geomorphological processes that might affect the isolation properties of a waste repository site. This study examines the use of the stable isotope ratios of oxygen ( 18 O/ 16 O) and carbon ( 13 C/ 12 C) in authigenic minerals as hydrogeochemical tools tracing low-temperature rock-water interaction in variably-saturated fractured stuff. Isotopic compositions of fracture-filling and rock matrix minerals in the Apache Leap tuff, near Superior, Arizona were concordant with geothermal temperatures and in equilibrium with water isotopically similar to present-day meteoric water and groundwater. Oxygen and carbon isotope ratios of fracture-filling, in unsaturated fractured tuff, displayed an isotopic gradient believed to result from near-surface isotopic enrichment due to evaporation rather than the effects of rock-water interaction. Oxygen isotope ratios of rock matrix opal samples exhibited an isotopic gradient believed to result from, leaching and reprecipitation of silica at depth. Methods and results can be used to further define primary flowpaths and the movement of water in variably-saturated fractured rock. 71 refs., 23 figs., 3 tabs

  9. Stable isotopes of authigenic minerals in variably-saturated fractured tuff

    Energy Technology Data Exchange (ETDEWEB)

    Weber, D.S.; Evans, D.D.

    1988-11-01

    Identifying stable isotope variation and mineralogical changes in fractured rock may help establish the history of climatic and geomorphological processes that might affect the isolation properties of a waste repository site. This study examines the use of the stable isotope ratios of oxygen ({sup 18}O/{sup 16}O) and carbon ({sup 13}C/{sup 12}C) in authigenic minerals as hydrogeochemical tools tracing low-temperature rock-water interaction in variably-saturated fractured stuff. Isotopic compositions of fracture-filling and rock matrix minerals in the Apache Leap tuff, near Superior, Arizona were concordant with geothermal temperatures and in equilibrium with water isotopically similar to present-day meteoric water and groundwater. Oxygen and carbon isotope ratios of fracture-filling, in unsaturated fractured tuff, displayed an isotopic gradient believed to result from near-surface isotopic enrichment due to evaporation rather than the effects of rock-water interaction. Oxygen isotope ratios of rock matrix opal samples exhibited an isotopic gradient believed to result from, leaching and reprecipitation of silica at depth. Methods and results can be used to further define primary flowpaths and the movement of water in variably-saturated fractured rock. 71 refs., 23 figs., 3 tabs.

  10. Comparison of oxygen saturation levels in patients receiving Technegas by the conventional unassisted method vs. the positive ventilation delivery system (PVDS)

    International Nuclear Information System (INIS)

    Dobson, M.P.; Leiper, C.A.; Lee, K.; Dixson, H.

    2000-01-01

    Full text: The purpose of this study is to compare oxygen saturation levels (SaO 2 ) in 289 patients undergoing conventional lung ventilation scintigraphy (control group) and 27 patients undergoing Positive Ventilation Delivery System (PVDS). The 27 patients where selected as their conventional method of inhalation proved to be inadequate or non-diagnostic. The patients underwent a second ventilation using PVDS, which improved the diagnostic quality of the ventilation image and assisted in clinical management decisions. Some patients in both the PVDS and the control group experienced a transient lowering in their SaO 2 . The mean initial SaO 2 in the control group did not fall below 94.9% and in the PVDS group measured 90.6%. 93% (25/27) of patients in the PVDS group were assessed as non CO 2 retaining, and received oxygen at 10L/min during Technegas inhalation. The mean trough saturation in the PVDS group was 91.7% which was significantly higher than that of the control group (86.9%). No patient in either group experienced any significant complication attributed to the transient tall in SaO 2 during technegas administration. We conclude that oxygen supplied as part of the PVDS system ameliorates the transient reduction in SaO 2 seen during standard Technegas administration. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  11. Decadal changes in the aragonite and calcite saturation state of the Pacific Ocean

    Science.gov (United States)

    Feely, Richard A.; Sabine, Christopher L.; Byrne, Robert H.; Millero, Frank J.; Dickson, Andrew G.; Wanninkhof, Rik; Murata, Akihiko; Miller, Lisa A.; Greeley, Dana

    2012-09-01

    Based on measurements from the WOCE/JGOFS global CO2 survey, the CLIVAR/CO2 Repeat Hydrography Program and the Canadian Line P survey, we have observed an average decrease of 0.34% yr-1 in the saturation state of surface seawater in the Pacific Ocean with respect to aragonite and calcite. The upward migrations of the aragonite and calcite saturation horizons, averaging about 1 to 2 m yr-1, are the direct result of the uptake of anthropogenic CO2 by the oceans and regional changes in circulation and biogeochemical processes. The shoaling of the saturation horizon is regionally variable, with more rapid shoaling in the South Pacific where there is a larger uptake of anthropogenic CO2. In some locations, particularly in the North Pacific Subtropical Gyre and in the California Current, the decadal changes in circulation can be the dominant factor in controlling the migration of the saturation horizon. If CO2 emissions continue as projected over the rest of this century, the resulting changes in the marine carbonate system would mean that many coral reef systems in the Pacific would no longer be able to sustain a sufficiently high rate of calcification to maintain the viability of these ecosystems as a whole, and these changes perhaps could seriously impact the thousands of marine species that depend on them for survival.

  12. Oxygen saturation in children with and without obstructive sleep apnea using the phone-oximeter.

    Science.gov (United States)

    Garde, Ainara; Karlen, Walter; Dehkordi, Parastoo; Wensley, David; Ansermino, J Mark; Dumont, Guy A

    2013-01-01

    Obstructive sleep apnea (OSA) in children can lead to daytime sleepiness, growth failure and developmental delay. Polysomnography (PSG), the gold standard to diagnose OSA is highly resource intensive and is confined to the sleep laboratory. In this study we propose to identify children with OSA using blood oxygen saturation (SpO2) obtained from the Phone Oximeter. This portable, in-home device is able to monitor patients over multiple nights, causes less sleep disturbance and facilitates a more natural sleep pattern. The proposed algorithm analyzes the SpO2 signal in the time and frequency domain using a 90-s sliding window. Three spectral parameters are calculated from the power spectral density (PSD) to evaluate the modulation in the SpO2 due to the oxyhemoblobin desaturations. The power P, slope S in the discriminant band (DB), and ratio R between P and total power are calculated for each window. Tendency and variability indices, number of SpO2 desaturations and time spent under 2% or 3% of baseline saturation level are computed for each time window. The statistical distribution of the temporal evolution of all parameters is analyzed to identify 68 children, 30 with OSA and 38 without OSA (nonOSA). This characterization was evaluated by a feature selection based on a linear discriminant. The combination of temporal and spectral parameters provided the best leave one out crossvalidation results with an accuracy of 86.8%, a sensitivity of 80.0%, and a specificity of 92.1% using only 5 parameters. The median of R, mean of P and S and mean and standard deviation of the number of desaturations below 3% of baseline saturation level, were the most representative parameters. Hence, a better knowledge of SpO2 dynamics could help identifying children with OSA with the Phone Oximeter.

  13. Soil aquifer treatment of artificial wastewater under saturated conditions

    KAUST Repository

    Essandoh, H. M K; Tizaoui, Chedly; Mohamed, Mostafa H A; Amy, Gary L.; Brdjanovic, Damir

    2011-01-01

    A 2000 mm long saturated laboratory soil column was used to simulate soil aquifer treatment under saturated conditions to assess the removal of chemical and biochemical oxygen demand (COD and BOD), dissolved organic carbon (DOC), nitrogen

  14. An algorithm for sensing venous oxygenation using ultrasound-modulated light enhanced by microbubbles

    Science.gov (United States)

    Honeysett, Jack E.; Stride, Eleanor; Deng, Jing; Leung, Terence S.

    2012-02-01

    Near-infrared spectroscopy (NIRS) can provide an estimate of the mean oxygen saturation in tissue. This technique is limited by optical scattering, which reduces the spatial resolution of the measurement, and by absorption, which makes the measurement insensitive to oxygenation changes in larger deep blood vessels relative to that in the superficial tissue. Acousto-optic (AO) techniques which combine focused ultrasound (US) with diffuse light have been shown to improve the spatial resolution as a result of US-modulation of the light signal, however this technique still suffers from low signal-to-noise when detecting a signal from regions of high optical absorption. Combining an US contrast agent with this hybrid technique has been proposed to amplify an AO signal. Microbubbles are a clinical contrast agent used in diagnostic US for their ability to resonate in a sound field: in this work we also make use of their optical scattering properties (modelled using Mie theory). A perturbation Monte Carlo (pMC) model of light transport in a highly absorbing blood vessel containing microbubbles surrounded by tissue is used to calculate the AO signal detected on the top surface of the tissue. An algorithm based on the modified Beer-Lambert law is derived which expresses intravenous oxygen saturation in terms of an AO signal. This is used to determine the oxygen saturation in the blood vessel from a dual wavelength microbubble-contrast AO measurement. Applying this algorithm to the simulation data shows that the venous oxygen saturation is accurately recovered, and this measurement is robust to changes in the oxygenation of the superficial tissue layer.

  15. SU-E-T-326: The Oxygen Saturation (SO2) and Breath-Holding Time Variation Applied Active Breathing Control (ABC)

    Energy Technology Data Exchange (ETDEWEB)

    Gong, G; Yin, Y [Shandong Cancer Hospital, Jinan, Shandong (China)

    2014-06-01

    Purpose: To study the oxygen saturation (SO2) and breath-holding time variation applied active breathing control (ABC) in radiotherapy of tumor. Methods: 24 volunteers were involved in our trials, and they all did breath-holding motion assisted by ELEKTA Active Breathing Coordinator 2.0 for 10 times respectively. And the patient monitor was used to observe the oxygen saturation (SO2) variation. The variation of SO2, and length of breath-holding time and the time for recovering to the initial value of SO2 were recorded and analyzed. Results: (1) The volunteers were divided into two groups according to the SO2 variation in breath-holding: A group, 14 cases whose SO2 reduction were more than 2% (initial value was 97% to 99%, while termination value was 91% to 96%); B group, 10 cases were less than 2% in breath-holding without inhaling oxygen. (2) The interfraction breath holding time varied from 8 to 20s for A group compared to the first breath-holding time, and for B group varied from 4 to 14s. (3) The breathing holding time of B group prolonged mean 8s, compared to A group. (4) The time for restoring to the initial value of SO2 was from 10s to 30s. And the breath-holding time shortened obviously for patients whose SO2 did not recover to normal. Conclusion: It is very obvious that the SO2 reduction in breath-holding associated with ABC for partial people. It is necessary to check the SO2 variation in breath training, and enough time should be given to recover SO2.

  16. Investigating Functional Extension of Optical Coherence Tomography for Spectroscopic Analysis of Blood Oxygen Saturation

    Science.gov (United States)

    Chen, Siyu

    Over the past two decades, optical coherence tomography (OCT) has been successfully applied to various fields of biomedical researching and clinical studies, including cardiology, urology, dermatology, dentistry, oncology, and most successfully, ophthalmology. This dissertation seeks to extend the current OCT practice, which is still largely morphology-based, into a new dimension, functional analysis of metabolic activities in vivo. More specifically, the investigation is focused on retrieving blood oxygen saturation (sO2) using intrinsic hemoglobin optical absorption contrast. Most mammalian cells rely on aerobic respiration to support cellular function, which means they consume oxygen to create adenosine triphosphate (ATP). Metabolic rate of oxygen (MRO2), a key hemodynamic parameter, characterizes how much oxygen is consumed during a given period of time, reflecting the metabolic activity of the target tissue. For example, retinal neurons are highly active and almost entirely rely on the moment-to-moment oxygen supply from retinal circulations. Thus, variation in MRO2 reveals the instantaneous activity of these neurons, shedding light on the physiological and pathophysiological change of cellular functions. Eventually, measuring MRO2 can potentially provide a biomarker for early-stage disease diagnosis, and serve as one benchmark for evaluating effectiveness of medical intervention during disease management. Essential in calculating MRO2, blood sO2 measurements using spectroscopic OCT analysis has been attempted as early as 2003. OCT is intrinsically sensitive to the blood optical absorption spectrum due to its wide-band illumination and detection scheme relying on back-scattered photon. However, accurate retrieval of blood sO2 using conventional near infrared (NIR) OCT systems in vivo has remained challenging. It was not until the development of OCT systems using visible light illumination (vis-OCT) when accurate measurement of blood sO2 was reported in live

  17. A theoretical model for the effects of reduced hemoglobin-oxygen affinity on tumor oxygenation

    International Nuclear Information System (INIS)

    Kavanagh, Brian D.; Secomb, Timothy W.; Hsu, Richard; Lin, P.-S.; Venitz, Jurgen; Dewhirst, Mark W.

    2002-01-01

    Purpose: To develop a theoretical model for oxygen delivery to tumors, and to use the model to simulate the effects of changing the affinity of hemoglobin for oxygen on tumor oxygenation. Methods and Materials: Hemoglobin affinity is expressed in terms of P 50 , the partial pressure of oxygen (Po 2 ) at half saturation. Effects of changing P 50 on arterial Po 2 are predicted using an effective vessel approach to describe diffusive oxygen transport in the lungs, assuming fixed systemic oxygen demand and fixed blood flow rate. The decline in oxygen content of blood as it flows through normal tissue before entering the tumor region is assumed fixed. The hypoxic fraction of the tumor region is predicted using a three-dimensional simulation of diffusion from a network of vessels whose geometry is derived from observations of tumor microvasculature in the rat. Results: In air-breathing rats, predicted hypoxic fraction decreases with moderate increases in P 50 , but increases with further increases of P 50 , in agreement with previous experimental results. In rats breathing hyperoxic gases, and in humans breathing either normoxic or hyperoxic gases, increased P 50 is predicted to improve tumor oxygenation. Conclusions: The results support the administration of synthetic agents to increase P 50 during radiation treatment of tumors

  18. Association between minor loading vein architecture and light- and CO2-saturated rates of photosynthetic oxygen evolution among Arabidopsis thaliana ecotypes from different latitudes

    Directory of Open Access Journals (Sweden)

    Christopher M Cohu

    2013-07-01

    Full Text Available Through microscopic analysis of veins and assessment of light- and CO2-saturated rates of photosynthetic oxygen evolution, we investigated the relationship between minor loading vein anatomy and photosynthesis of mature leaves in three ecotypes of Arabidopsis thaliana grown under four different combinations of temperature and photon flux density (PFD. All three ecotypes exhibited greater numbers and cross-sectional area of phloem cells as well as higher photosynthesis rates in response to higher PFD and especially lower temperature. The Swedish ecotype exhibited the strongest response to these conditions, the Italian ecotype the weakest response, and the Col-0 ecotype exhibited an intermediate response. Among all three ecotypes, strong linear relationships were found between light- and CO2-saturated rates of photosynthetic oxygen evolution and the number and area of either sieve elements or of companion and phloem parenchyma cells in foliar minor loading veins, with the Swedish ecotype showing the highest number of cells in minor loading veins (and largest minor veins coupled with unprecedented high rates of photosynthesis. Linear, albeit less significant, relationships were also observed between number and cross-sectional area of tracheids per minor loading vein versus light- and CO2-saturated rates of photosynthetic oxygen evolution. We suggest that sugar distribution infrastructure in the phloem is co-regulated with other features that set the upper limit for photosynthesis. The apparent genetic differences among Arabidopsis ecotypes should allow for future identification of the gene(s involved in augmenting sugar-loading and -transporting phloem cells and maximal rates of photosynthesis.

  19. Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes.

    Science.gov (United States)

    Seifi, Sohila; Khatony, Alireza; Moradi, Gholamreza; Abdi, Alireza; Najafi, Farid

    2018-01-01

    Heart surgery patients are more at risk of poor peripheral perfusion, and peripheral capillary oxygen saturation (SpO2) measurement is regular care for continuous analysis of blood oxygen saturation in these patients. With regard to controversial studies on accuracy of the current pulse oximetry probes and lack of data related to patients undergoing heart surgery, the present study was conducted to determine accuracy of pulse oximetry probes of finger, toe, forehead and earlobe in detection of oxygen saturation in patients admitted to intensive care units for coronary artery bypass surgery. In this clinical trial, 67 patients were recruited based on convenience sampling method among those admitted to intensive care units for coronary artery bypass surgery. The SpO2 value was measured using finger, toe, forehead and earlobe probes and then compared with the standard value of arterial oxygen saturation (SaO2). Data were entered into STATA-11 software and analyzed using descriptive, inferential and Bland-Altman statistical analyses. Highest and lowest correlational mean values of SpO2 and SaO2 were related to finger and earlobe probes, respectively. The highest and lowest agreement of SpO2 and SaO2 were related to forehead and earlobe probes. The SpO2 of earlobe probes due to lesser mean difference, more limited confidence level and higher agreement ration with SaO2 resulted by arterial blood gas (ABG) analysis had higher accuracy. Thus, it is suggested to use earlobe probes in patients admitted to the intensive care unit for coronary artery bypass surgery. Registration of this trial protocol has been approved in Iranian Registry of Clinical Trials at 2018-03-19 with reference IRCT20100913004736N22. "Retrospectively registered."

  20. Closed Loop Control of Oxygen Delivery and Oxygen Generation

    Science.gov (United States)

    2017-08-01

    were used for this study and were connected via a USB cable to allow communication. The ventilator was modified to allow closed loop control of oxygen...connected via a USB cable to allow communication. The ventilator was modified to allow closed loop control of oxygen based on the oxygen saturation...2017-4119, 28 Aug 2017. oximetry (SpO2) and intermittent arterial blood sampling for arterial oxygen tension (partial pressure of oxygen [PaO2]) and

  1. Cardiac function and oxygen saturation during maximal breath-holding in air and during whole-body surface immersion.

    Science.gov (United States)

    Marabotti, Claudio; Piaggi, Paolo; Menicucci, Danilo; Passera, Mirko; Benassi, Antonio; Bedini, Remo; L'Abbate, Antonio

    2013-09-01

    The magnitude of the oxygen-sparing effect induced by the diving response in humans is still under debate. We wished to compare cardiovascular changes during maximal breath-holding (BH) in air and during whole-body immersion at the surface in a group of BH divers. Twenty-one divers performed a maximal static apnea in air or during whole-body immersion. Dopplerechocardiography, arterial blood pressure and haemoglobin saturation (SaO₂) were obtained at the beginning of, and at 1/3, 2/3 and maximal BH time. BH time was on the average 3.6 ± 0.4 min, with no differences between the two conditions. SaO₂ significantly decreased during BH in both conditions, but was significantly higher during immersion as compared to the dry (P = 0.04). In both conditions, BH induced a significant linear increase in right ventricular diameter (P whole-body immersion, associated with reduced LV ejection fraction and progressive hindrance to diastolic filling. For a similar apnea duration, SaO₂ decreased less during immersed BH, indicating an O₂-sparing effect of diving, suggesting that interruption of apnea was not triggered by a threshold critical value of blood O₂ desaturation.

  2. EFFECTIVENESS OF AUTOGENIC DRAINAGE VERSUS POSTURAL DRAINAGE ON OXYGEN SATURATION IN PATIENTS WITH CHRONIC BRONCHITIS WITH 15 MINUTES POST THERAPY

    OpenAIRE

    V. Kiran; Dr. Bhimasen .S; E. Mastanaiah; A. Thiruppathi

    2014-01-01

    Background: Patients with COPD will have more amount of secretions. To clear the secretions by using of different bronchial hygiene techniques like postural drainage and autogenic drainage technique, manual hyperventilation technique ,active cycle breathing technique .Hence in this study to compare the short-term effects of postural drainage with clapping (PD) and autogenic drainage (AD) on level of oxygen saturation in blood, and amount of sputum recovery. Methodology: The study was done ...

  3. Simultaneous Imaging of CBF Change and BOLD with Saturation-Recovery-T1 Method.

    Directory of Open Access Journals (Sweden)

    Xiao Wang

    Full Text Available A neuroimaging technique based on the saturation-recovery (SR-T1 MRI method was applied for simultaneously imaging blood oxygenation level dependence (BOLD contrast and cerebral blood flow change (ΔCBF, which is determined by CBF-sensitive T1 relaxation rate change (ΔR1CBF. This technique was validated by quantitatively examining the relationships among ΔR1CBF, ΔCBF, BOLD and relative CBF change (rCBF, which was simultaneously measured by laser Doppler flowmetry under global ischemia and hypercapnia conditions, respectively, in the rat brain. It was found that during ischemia, BOLD decreased 23.1±2.8% in the cortical area; ΔR1CBF decreased 0.020±0.004s-1 corresponding to a ΔCBF decrease of 1.07±0.24 ml/g/min and 89.5±1.8% CBF reduction (n=5, resulting in a baseline CBF value (=1.18 ml/g/min consistent with the literature reports. The CBF change quantification based on temperature corrected ΔR1CBF had a better accuracy than apparent R1 change (ΔR1app; nevertheless, ΔR1app without temperature correction still provides a good approximation for quantifying CBF change since perfusion dominates the evolution of the longitudinal relaxation rate (R1app. In contrast to the excellent consistency between ΔCBF and rCBF measured during and after ischemia, the BOLD change during the post-ischemia period was temporally disassociated with ΔCBF, indicating distinct CBF and BOLD responses. Similar results were also observed for the hypercapnia study. The overall results demonstrate that the SR-T1 MRI method is effective for noninvasive and quantitative imaging of both ΔCBF and BOLD associated with physiological and/or pathological changes.

  4. Higher cerebral oxygen saturation may provide higher urinary output during continuous regional cerebral perfusion

    Directory of Open Access Journals (Sweden)

    Tomoyasu Takahiro

    2008-10-01

    Full Text Available Abstract Objective We examined the hypothesis that higher cerebral oxygen saturation (rSO2 during RCP is correlated with urinary output. Methods Between December 2002 and August 2006, 12 patients aged 3 to 61 days and weighing 2.6 to 3.4 kg underwent aortic arch repair with RCP. Urinary output and rSO2 were analyzed retrospectively. Data were assigned to either of 2 groups according to their corresponding rSO2: Group A (rSO2 ≦ 75% and Group B (rSO2 Results Seven and 5 patients were assigned to Group A and Group B, respectively. Group A was characterized by mean radial arterial pressure (37.9 ± 9.6 vs 45.8 ± 7.8 mmHg; P = 0.14 and femoral arterial pressure (6.7 ± 6.1 vs 20.8 ± 14.6 mmHg; P = 0.09 compared to Group B. However, higher urinary output during CPB (1.03 ± 1.18 vs 0.10 ± 0.15 ml·kg-1·h-1; P = 0.03. Furthermore our results indicate that a higher dose of Chlorpromazine was used in Group A (2.9 ± 1.4 vs 1.7 ± 1.0 mg/kg; P = 0.03. Conclusion Higher cerebral oxygenation may provide higher urinary output due to higher renal blood flow through collateral circulation.

  5. Projections of climate-driven changes in tuna vertical habitat based on species-specific differences in blood oxygen affinity.

    Science.gov (United States)

    Mislan, K A S; Deutsch, Curtis A; Brill, Richard W; Dunne, John P; Sarmiento, Jorge L

    2017-10-01

    Oxygen concentrations are hypothesized to decrease in many areas of the ocean as a result of anthropogenically driven climate change, resulting in habitat compression for pelagic animals. The oxygen partial pressure, pO 2 , at which blood is 50% saturated (P 50 ) is a measure of blood oxygen affinity and a gauge of the tolerance of animals for low ambient oxygen. Tuna species display a wide range of blood oxygen affinities (i.e., P 50 values) and therefore may be differentially impacted by habitat compression as they make extensive vertical movements to forage on subdaily time scales. To project the effects of end-of-the-century climate change on tuna habitat, we calculate tuna P 50 depths (i.e., the vertical position in the water column at which ambient pO 2 is equal to species-specific blood P 50 values) from 21st century Earth System Model (ESM) projections included in the fifth phase of the Climate Model Intercomparison Project (CMIP5). Overall, we project P 50 depths to shoal, indicating likely habitat compression for tuna species due to climate change. Tunas that will be most impacted by shoaling are Pacific and southern bluefin tunas-habitat compression is projected for the entire geographic range of Pacific bluefin tuna and for the spawning region of southern bluefin tuna. Vertical shifts in P 50 depths will potentially influence resource partitioning among Pacific bluefin, bigeye, yellowfin, and skipjack tunas in the northern subtropical and eastern tropical Pacific Ocean, the Arabian Sea, and the Bay of Bengal. By establishing linkages between tuna physiology and environmental conditions, we provide a mechanistic basis to project the effects of anthropogenic climate change on tuna habitats. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  6. Near-simultaneous hemoglobin saturation and oxygen tension maps in mouse brain using an AOTF microscope.

    Science.gov (United States)

    Shonat, R D; Wachman, E S; Niu, W; Koretsky, A P; Farkas, D L

    1997-09-01

    A newly developed microscope using acousto-optic tunable filters (AOTFs) was used to generate in vivo hemoglobin saturation (SO2) and oxygen tension (PO2) maps in the cerebral cortex of mice. SO2 maps were generated from the spectral analysis of reflected absorbance images collected at different wavelengths, and PO2 maps were generated from the phosphorescence lifetimes of an injected palladium-porphyrin compound using a frequency-domain measurement. As the inspiratory O2 was stepped from hypoxia (10% O2), through normoxia (21% O2), to hyperoxia (60% O2), measured SO2 and PO2 levels rose accordingly and predictably throughout. A plot of SO2 versus PO2 in different arterial and venous regions of the pial vessels conformed to the sigmoidal shape of the oxygen-hemoglobin dissociation curve, providing further validation of the two mapping procedures. The study demonstrates the versatility of the AOTF microscope for in vivo physiologic investigation, allowing for the generation of nearly simultaneous SO2 and PO2 maps in the cerebral cortex, and the frequency-domain detection of phosphorescence lifetimes. This class of study opens up exciting new possibilities for investigating the dynamics of hemoglobin and O2 binding during functional activation of neuronal tissues.

  7. A new fibre optic pulse oximeter probe for monitoring splanchnic organ arterial blood oxygen saturation.

    Science.gov (United States)

    Hickey, M; Samuels, N; Randive, N; Langford, R; Kyriacou, P A

    2012-12-01

    A new, continuous method of monitoring splanchnic organ oxygen saturation (SpO(2)) would make the early detection of inadequate tissue oxygenation feasible, reducing the risk of hypoperfusion, severe ischaemia, and, ultimately, death. In an attempt to provide such a device, a new fibre optic based reflectance pulse oximeter probe and processing system were developed followed by an in vivo evaluation of the technology on seventeen patients undergoing elective laparotomy. Photoplethysmographic (PPG) signals of good quality and high signal-to-noise ratio were obtained from the small bowel, large bowel, liver and stomach. Simultaneous peripheral PPG signals from the finger were also obtained for comparison purposes. Analysis of the amplitudes of all acquired PPG signals indicated much larger amplitudes for those signals obtained from splanchnic organs than those obtained from the finger. Estimated SpO(2) values for splanchnic organs showed good agreement with those obtained from the finger fibre optic probe and those obtained from a commercial device. These preliminary results suggest that a miniaturized 'indwelling' fibre optic sensor may be a suitable method for pre-operative and post-operative evaluation of splanchnic organ SpO(2) and their health. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Assessment of muscle tissue oxygen saturation after out-of-hospital cardiac arrest.

    Science.gov (United States)

    Orban, Jean-Christophe; Scarlatti, Audrey; Danin, Pierre-Eric; Dellamonica, Jean; Bernardin, Gilles; Ichai, Carole

    2015-12-01

    Pathophysiology of cardiac arrest corresponds to an ischemia-reperfusion syndrome with deep impairment of microcirculation. Muscular tissue oxygen saturation (StO2) is a noninvasive method of evaluation of microcirculation. Our study was aimed at assessing the prognosis value of muscular StO2 in patients admitted for out-of-hospital cardiac arrest (OHCA) and treated with hypothermia. We conducted a prospective bicentric observational study including OHCA patients treated with therapeutic hypothermia. Baseline StO2, derived variables (desaturation and resaturation slopes), and lactate levels were compared at different times between patients with good and poor outcomes. Prognosis was assessed by the Cerebral Performance Category (CPC) score at 6 months after admission (CPC 1-2, good outcome; CPC 3-5, poor outcome). Forty-four patients were included, 17 good and 27 poor outcomes at 6 months. At admission, StO2 and lactate levels were lower in good outcome patients. Desaturation and resaturation slopes did not differ between groups. After an OHCA treated with therapeutic hypothermia, StO2 was correlated with outcome. Further research is needed to better understand the pathophysiological process underlying our results. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Intelligent Approach for Analysis of Respiratory Signals and Oxygen Saturation in the Sleep Apnea/Hypopnea Syndrome

    Science.gov (United States)

    Moret-Bonillo, Vicente; Alvarez-Estévez, Diego; Fernández-Leal, Angel; Hernández-Pereira, Elena

    2014-01-01

    This work deals with the development of an intelligent approach for clinical decision making in the diagnosis of the Sleep Apnea/Hypopnea Syndrome, SAHS, from the analysis of respiratory signals and oxygen saturation in arterial blood, SaO2. In order to accomplish the task the proposed approach makes use of different artificial intelligence techniques and reasoning processes being able to deal with imprecise data. These reasoning processes are based on fuzzy logic and on temporal analysis of the information. The developed approach also takes into account the possibility of artifacts in the monitored signals. Detection and characterization of signal artifacts allows detection of false positives. Identification of relevant diagnostic patterns and temporal correlation of events is performed through the implementation of temporal constraints. PMID:25035712

  10. Performance evaluation of photoacoustic oximetry imaging systems using a dynamic blood flow phantom with tunable oxygen saturation

    Science.gov (United States)

    Vogt, William C.; Zhou, Xuewen; Andriani, Rudy; Wear, Keith A.; Garra, Brian S.; Pfefer, Joshua

    2018-02-01

    Photoacoustic Imaging (PAI) is an emerging technology with strong potential for broad clinical applications from breast cancer detection to cerebral monitoring due to its ability to compute maps of blood oxygen saturation (SO2) distribution in deep tissues using multispectral imaging. However, no well-validated consensus test methods currently exist for evaluating oximetry-specific performance characteristics of PAI devices. We have developed a phantombased flow system capable of rapid SO2 adjustment to serve as a test bed for elucidation of factors impacting SO2 measurement and quantitative characterization of device performance. The flow system is comprised of a peristaltic pump, membrane oxygenator, oxygen and nitrogen gas, and in-line oxygen, pH, and temperature sensors that enable real-time estimation of SO2 reference values. Bovine blood was delivered through breast-relevant tissue phantoms containing vessel-mimicking fluid channels, which were imaged using a custom multispectral PAI system. Blood was periodically drawn for SO2 measurement in a clinical-grade CO-oximeter. We used this flow phantom system to evaluate the impact of device parameters (e.g.,wavelength-dependent fluence corrections) and tissue parameters (e.g. fluid channel depth, blood SO2, spectral coloring artifacts) on oximetry measurement accuracy. Results elucidated key challenges in PAI oximetry and device design trade-offs, which subsequently allowed for optimization of system performance. This approach provides a robust benchtop test platform that can support PAI oximetry device optimization, performance validation, and clinical translation, and may inform future development of consensus test methods for performance assessment of photoacoustic oximetry imaging systems.

  11. Determination of oxygen in liquid sodium

    International Nuclear Information System (INIS)

    Torre, M. de la; Lapena, J.; Galindo, F.; Couchoud, M.; Celis, B. de; Lopez-Araquistain, J.L.

    1976-01-01

    The behaviour is analysed of a device for 'in-line' sampling and vacuum distillation. With this procedure 95 results were obtained for the solubility of oxygen in liquid sodium at temperatures between 125 0 and 300 0 C. The correlation between the concentration of oxygen in a saturation state and the corresponding temperature is represented by: 1g C = 6,17 - 2398/T, where C expressed ppm of oxygen by weight and T is the saturation temperature in 0 K. Reference is also made to the first results obtained with the electrochemical oxygen meter and the system for taking and recording data. (author)

  12. Decadal oxygen change in the eastern tropical North Atlantic

    Directory of Open Access Journals (Sweden)

    J. Hahn

    2017-07-01

    Full Text Available Repeat shipboard and multi-year moored observations obtained in the oxygen minimum zone (OMZ of the eastern tropical North Atlantic (ETNA were used to study the decadal change in oxygen for the period 2006–2015. Along 23° W between 6 and 14° N, oxygen decreased with a rate of −5.9 ± 3.5 µmol kg−1 decade−1 within the depth covering the deep oxycline (200–400 m, while below the OMZ core (400–1000 m oxygen increased by 4.0 ± 1.6 µmol kg−1 decade−1 on average. The inclusion of these decadal oxygen trends in the recently estimated oxygen budget for the ETNA OMZ suggests a weakened ventilation of the upper 400 m, whereas the ventilation strengthened homogeneously below 400 m. The changed ventilation resulted in a shoaling of the ETNA OMZ of −0.03 ± 0.02 kg m−3 decade−1 in density space, which was only partly compensated by a deepening of isopycnal surfaces, thus pointing to a shoaling of the OMZ in depth space as well (−22 ± 17 m decade−1. Based on the improved oxygen budget, possible causes for the changed ventilation are analyzed and discussed. Largely ruling out other ventilation processes, the zonal advective oxygen supply stands out as the most probable budget term responsible for the decadal oxygen changes.

  13. Description of saturation curves and boiling process of dry air

    Directory of Open Access Journals (Sweden)

    Vestfálová Magda

    2018-01-01

    Full Text Available Air is a mixture of gases forming the gas wrap of Earth. It is formed by dry air, moisture and other pollutants. Dry air is a substance whose thermodynamic properties in gaseous state, as well as the thermodynamic properties of its main constituents in gaseous state, are generally known and described in detail in the literature. The liquid air is a bluish liquid and is industrially used to produce oxygen, nitrogen, argon and helium by distillation. The transition between the gaseous and liquid state (the condensation process, resp. boiling process, is usually displayed in the basic thermodynamic diagrams using the saturation curves. The saturation curves of all pure substances are of a similar shape. However, since the dry air is a mixture, the shapes of its saturation curves are modified relative to the shapes corresponding to the pure substances. This paper deals with the description of the dry air saturation curves as a mixture, i.e. with a description of the process of phase change of dry air (boiling process. The dry air saturation curves are constructed in the basic thermodynamic charts based on the values obtained from the literature. On the basis of diagrams, data appearing in various publications are interpreted and put into context with boiling process of dry air.

  14. Changes in muscle tissue oxygenation during stagnant ischemia in septic patients.

    Science.gov (United States)

    Pareznik, Roman; Knezevic, Rajko; Voga, Gorazd; Podbregar, Matej

    2006-01-01

    To determine changes in the rate of thenar muscles tissue deoxygenation during stagnant ischemia in patients with severe sepsis and septic shock. Prospective observational study in the medical ICU of a general hospital. Consecutive patients admitted to ICU with septic shock (n=6), severe sepsis (n=6), localized infection (n=3), and healthy volunteers (n=15). Upper limb ischemia was induced by rapid automatic pneumatic cuff inflation around upper arm. Thenar muscle tissue oxygen saturation (StO2) was measured continuously by near-infrared spectroscopy before and during upper limb ischemia. StO(2) before intervention was comparable in patients with septic shock, severe sepsis, or localized infection and healthy volunteers (89 [65, 92]% vs. 82 [72, 91]% vs. 87 [85, 92]% vs. 83 [79, 93]%, respectively; p>0.1). The rate of StO(2) decrease during stagnant ischemia after initial hemodynamic stabilization was slower in septic shock patients than in those with severe sepsis or localized infection and in controls (-7.0 [-3.6, -11.0] %/min vs. -10.4 [-7.8, -13.3] %/min vs. -19.5 [-12.3, -23.3] vs. -37.4 [-27.3, -56.2] %/min, respectively; p=0.041). At ICU discharge the rate of StO2 decrease did not differ between the septic shock, severe sepsis, and localized infection groups (-17.0 [-9.3, -28.9] %/min vs. -19.9 [-13.3, -23.6] %/min vs. -23.1 [-20.7, -26.2] %/min, respectively), but remained slower than in controls (p<0.01). The rate of StO2 decrease was correlated with Sequential Organ Failure Assessment (SOFA) score (r=0.739, p<0.001). After hemodynamic stabilization thenar muscle tissue oxygen saturation during stagnant ischemia decreases slower in septic shock patients than in patients with severe sepsis or localized infection and in healthy volunteers. During ICU stay and improvement of sepsis the muscle tissue deoxygenation rate increases in survivors of both septic shock and severe sepsis and was correlated with SOFA score.

  15. Effect of oxygen treatment on heart rate after abdominal surgery

    DEFF Research Database (Denmark)

    Rosenberg-Adamsen, S; Lie, C; Bernhard, A

    1999-01-01

    BACKGROUND: Cardiac complications are common during the postoperative period and may be associated with hypoxemia and tachycardia. Preliminary studies in high-risk patients after operation have shown a possible beneficial effect of oxygen therapy on arterial oxygen saturation and heart rate....... METHODS: The authors studied the effect of oxygen therapy on arterial oxygen saturation and heart rate in 100 consecutive unselected patients randomly and double blindly allocated to receive air or oxygen therapy between the first and fourth day after major abdominal surgery. RESULTS: The median arterial...... oxygen saturation rate increased significantly from 96% to 99% (P heart rate decreased significantly from 85 beats/min to 81 beats/min (P heart rate occurred...

  16. Damage saturation effects on volume and resistivity changes induced by fission-fragment irradiation of copper

    International Nuclear Information System (INIS)

    Birtcher, R.C.; Blewitt, T.H.

    1981-01-01

    Damage production and saturation has been monitored in copper by simultaneous electrical resistivity- and length-change measurements. Damage was introduced by 235 U fission fragments at either 7 or 85 K. At both temperatures, the resistivity and length changes were linearly related to each other for resistivity changes less than 80% saturation resistivity. The linear relationship was the same for both irradiation temperatures and was the same as that observed previously for 10 B fission fragment irrations at 4 K. These results are interpreted to show that the resistivity change per defect is unaffected by irradiation under conditions which lead to interstitial clustering. (orig.)

  17. Correlation between near-infrared spectroscopy and magnetic resonance imaging of rat brain oxygenation modulation

    International Nuclear Information System (INIS)

    Chen Yu; Tailor, Dharmesh R; Intes, Xavier; Chance, Britton

    2003-01-01

    We measure the tissue oxygen and haemoglobin concentrations in the rat brain during modulation of inhaled oxygen concentration (FiO 2 ), using non-invasive frequency domain near-infrared oximetry. The rise in oxygenated haemoglobin concentration and the decline in deoxygenated haemoglobin concentration are demonstrated in correspondence with the modulation of FiO 2 , which is changed from 20% to 100% in increments of 20%. Furthermore, the tissue oxygenation saturation also shows the corresponding trend and changes ranging from approximately 70% to 90%. The relative changes in deoxygenated haemoglobin concentration are compared to the blood-oxygenation-level-dependent (BOLD) MRI signal recorded during a similar FiO 2 protocol. A linear relationship with high correlation coefficient between the relative changes in the BOLD MRI signal and the NIRS signal is observed

  18. Correlation between near-infrared spectroscopy and magnetic resonance imaging of rat brain oxygenation modulation

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yu [Department of Biochemistry and Biophysics, University of Pennsylvania, Philadelphia, PA (United States); Tailor, Dharmesh R [Department of Bioengineering, University of Pennsylvania, Philadelphia, PA (United States); Intes, Xavier [Department of Biochemistry and Biophysics, University of Pennsylvania, Philadelphia, PA (United States); Chance, Britton [Department of Biochemistry and Biophysics, University of Pennsylvania, Philadelphia, PA (United States)

    2003-02-21

    We measure the tissue oxygen and haemoglobin concentrations in the rat brain during modulation of inhaled oxygen concentration (FiO{sub 2}), using non-invasive frequency domain near-infrared oximetry. The rise in oxygenated haemoglobin concentration and the decline in deoxygenated haemoglobin concentration are demonstrated in correspondence with the modulation of FiO{sub 2}, which is changed from 20% to 100% in increments of 20%. Furthermore, the tissue oxygenation saturation also shows the corresponding trend and changes ranging from approximately 70% to 90%. The relative changes in deoxygenated haemoglobin concentration are compared to the blood-oxygenation-level-dependent (BOLD) MRI signal recorded during a similar FiO{sub 2} protocol. A linear relationship with high correlation coefficient between the relative changes in the BOLD MRI signal and the NIRS signal is observed.

  19. Investigation of induced changes after treatment with ionizing radiation and saturated steam in the case of paprika

    International Nuclear Information System (INIS)

    Kispeter, J.; Bajusz-Kabok, K.; Fekete, M.; Szabo, G.; Fodor, E.; Pali, T.

    2002-01-01

    Complete text of publication follows. Beside conventional food preservation methods, such new physical methods are also applied as ionising radiation, high hydrostatic pressure, high-tension gradient, fluctuating strong magnetic field as well as treatments with high-pressure saturated steam and microwaves. Since radiation treatment is the best known, it can be regarded as a basic method in comparative tests. In our work the preservation-induced changes were investigated for paprika griests of various origin and quality (different dyestuff contents). Samples were treated with ionising radiation, high-pressure saturated steam (140 deg C, 30 s) or with combinations of these. The changes were followed as a function of absorbed dose (2, 5, 7.5, 10 kGy) and storage time (0, 1, 2, 4, 12 weeks) using colour measurements, rheological and ESR methods. Our results are summarised as follows: (1) The treatment with high-pressure saturated steam is equivalent to that of 5 kGy absorbed γ-doses. Significant changes in dyestuff contents and surface colours can't be detected immediately after treatments. After storage of 12 weeks, decomposition of dyestuffs and changes in surface colours in samples treated with saturated steam are 20% greater than in control. Radiation results in a slight (few %) dyestuff decomposition and colour change (i.e. discolouration). (2) Rheological characteristics were changed in both treatments (apparent viscosities were increased) during storage. This is a reversible and permanent change in the case of treatments with ionising radiation and with high-pressure saturated steam, respectively. (3) Changes induced by microwave treatment are in accordance with rheological changes. (4) Treatment with saturated steam results in a decrease in the cellulose free radical content. The decrease is inversely proportional to dyestuff contents. (5) Decrease of cellulose radical concentration with the storage time is of exponential-like character. Radicals disappear at

  20. Evaluation of pulse-oximetry oxygen saturation taken through skin protective covering

    Science.gov (United States)

    James, Jyotsna; Tiwari, Lokesh; Upadhyay, Pramod; Sreenivas, Vishnubhatla; Bhambhani, Vikas; Puliyel, Jacob M

    2006-01-01

    Background The hard edges of adult finger clip probes of the pulse oximetry oxygen saturation (POOS) monitor can cause skin damage if used for prolonged periods in a neonate. Covering the skin under the probe with Micropore surgical tape or a gauze piece might prevent such injury. The study was done to see if the protective covering would affect the accuracy of the readings. Methods POOS was studied in 50 full-term neonates in the first week of life. After obtaining consent from their parents the neonates had POOS readings taken directly (standard technique) and through the protective covering. Bland-Altman plots were used to compare the new method with the standard technique. A test of repeatability for each method was also performed. Results The Bland-Altman plots suggest that there is no significant loss of accuracy when readings are taken through the protective covering. The mean difference was 0.06 (SD of 1.39) and 0.04 (SD 1.3) with Micropore and gauze respectively compared to the standard method. The mean difference was 0.22 (SD 0.23) on testing repeatability with the standard method. Conclusion Interposing Micropore or gauze does not significantly affect the accuracy of the POOS reading. The difference between the standard method and the new method was less than the difference seen on testing repeatability of the standard method. PMID:16677394

  1. Cryospectrophotometric determination of tumor intravascular oxyhemoglobin saturations: dependence on vascular geometry and tumor growth.

    Science.gov (United States)

    Fenton, B M; Rofstad, E K; Degner, F L; Sutherland, R M

    1988-12-21

    To delineate the complex relationships between overall tumor oxygenation and vascular configuration, intravascular oxyhemoglobin (HbO2) saturation distributions were measured with cryospectrophotometric techniques. Four factors related to vascular morphometry and tumor growth were evaluated: a) vessel diameter, b) distance of vessel from the tumor surface, c) tumor volume, and d) vascular density. To measure intertumor heterogeneity, two murine sarcomas (RIF-1 and KHT) and two human ovarian carcinoma xenografts (OWI and MLS) were utilized. In contrast to skeletal muscle, a preponderance of very low HbO2 saturations was observed for both large and small tumors of all lines. Saturations up to about 90% were also generally present, however, even in very large tumors. Variations in vascular configuration were predominantly tumor-line dependent rather than due to inherent characteristics of the host vasculature, and widely disparate HbO2 distributions were found for alternate lines implanted in identical host mice. Although peripheral saturations remained fairly constant with tumor growth, HbO2 values were markedly lower for vessels nearer the tumor center and further decreased with increasing tumor volume. HbO2 saturations did not change substantially with increasing vascular density (except for KHT tumors), although density did decrease with increasing distance from tumor surface. Combined effects of vessel diameter, tumor volume, and vessel location on HbO2 saturations were complex and varied markedly with both tumor line and vessel class. For specific classes, HbO2 distributions correlated closely with radiobiological hypoxic fractions, i.e., for tumor lines in which hypoxic fraction increased substantially with tumor volume, corresponding HbO2 values decreased, while for lines in which hypoxic fraction remained constant, HbO2 values also were unchanged. Although these trends may also be a function of differing oxygen consumption rates between tumor lines

  2. The oxygen-conserving potential of the diving response: A kinetic-based analysis.

    Science.gov (United States)

    Costalat, Guillaume; Coquart, Jeremy; Castres, Ingrid; Joulia, Fabrice; Sirost, Olivier; Clua, Eric; Lemaître, Frédéric

    2017-04-01

    We investigated the oxygen-conserving potential of the human diving response by comparing trained breath-hold divers (BHDs) to non-divers (NDs) during simulated dynamic breath-holding (BH). Changes in haemodynamics [heart rate (HR), stroke volume (SV), cardiac output (CO)] and peripheral muscle oxygenation [oxyhaemoglobin ([HbO 2 ]), deoxyhaemoglobin ([HHb]), total haemoglobin ([tHb]), tissue saturation index (TSI)] and peripheral oxygen saturation (SpO 2 ) were continuously recorded during simulated dynamic BH. BHDs showed a breaking point in HR kinetics at mid-BH immediately preceding a more pronounced drop in HR (-0.86 bpm.% -1 ) while HR kinetics in NDs steadily decreased throughout BH (-0.47 bpm.% -1 ). By contrast, SV remained unchanged during BH in both groups (all P > 0.05). Near-infrared spectroscopy (NIRS) results (mean ± SD) expressed as percentage changes from the initial values showed a lower [HHb] increase for BHDs than for NDs at the cessation of BH (+24.0 ± 10.1 vs. +39.2 ± 9.6%, respectively; P kinetic-based approach we used provides further credence to the concept of an "oxygen-conserving breaking point" in the human diving response.

  3. Inspiratory Muscle Training and Arterial Blood Oxygen Saturation in Patients With Chronic Obstructive Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Bakhshandeh Bavarsad

    2015-01-01

    Full Text Available Background One of the problems of the patients with chronic obstructive pulmonary disease (COPD is the weakness of the respiratory muscles that causes oxygen desaturation at rest and activity and decreases exercise tolerance. Objectives This study aimed to investigate the effect of inspiratory muscle training on arterial oxygen saturation (SPO2. Patients and Methods Forty patients with mild to very severe COPD were recruited for this study, which is a randomized control trail. The patients were randomized to IMT (inspiratory muscle training and control group. Training was performed with Respivol (a kind of inspiratory muscle trainer for 8 weeks (15 min/d for 6 d/week. SPSS software version 16 was used to analyze the data by performing independent t test, paired t test, and Fisher exact test. Results Results showed that, after 8 weeks of inspiratory muscle training, there was a little increase (but not statistically significant improvement in SPO2 (from 92.6 ± 8.71 % to 95.13 ± 7.08 %, with P = 0.06, whereas it remained unchanged in the control group (from 96.0 ± 3.46 % to 96.4 ± 3.35 % with P = 0.51. No statistically significant difference was seen between the two groups (P > 0.05. Conclusions Although inspiratory muscles training can prevent desaturation, which is caused by activity, it fails to improve it.

  4. In-vivo quantitative measurement of tissue oxygen saturation of human webbing using a transmission type continuous-wave near-infrared spectroscopy

    Science.gov (United States)

    Aizimu, Tuerxun; Adachi, Makoto; Nakano, Kazuya; Ohnishi, Takashi; Nakaguchi, Toshiya; Takahashi, Nozomi; Nakada, Taka-aki; Oda, Shigeto; Haneishi, Hideaki

    2018-02-01

    Near-infrared spectroscopy (NIRS) is a noninvasive method for monitoring tissue oxygen saturation (StO2). Many commercial NIRS devices are presently available. However, the precision of those devices is relatively poor because they are using the reflectance-model with which it is difficult to obtain the blood volume and other unchanged components of the tissue. Human webbing is a thin part of the hand and suitable to measure spectral transmittance. In this paper, we present a method for measuring StO2 of human webbing from a transmissive continuous-wave nearinfrared spectroscopy (CW-NIRS) data. The method is based on the modified Beer-Lambert law (MBL) and it consists of two steps. In the first step, we give a pressure to the upstream region of the measurement point to perturb the concentration of deoxy- and oxy-hemoglobin as remaining the other components and measure the spectral signals. From the measured data, spectral absorbance due to the components other than hemoglobin is calculated. In the second step, spectral measurement is performed at arbitrary time instance and the spectral absorbance obtained in the step 1 is subtracted from the measured absorbance. The tissue oxygen saturation (StO2) is estimated from the remained data. The method was evaluated on an arterial occlusion test (AOT) and a venous occlusion test (VOT). In the evaluation experiment, we confirmed that reasonable values of StO2 were obtained by the proposed method.

  5. Temperature effects on hemocyanin oxygen binding in an antarctic cephalopod.

    Science.gov (United States)

    Zielinski, S; Sartoris, F J; Pörtner, H O

    2001-02-01

    The functional relevance of oxygen transport by hemocyanin of the Antarctic octopod Megaleledone senoi and of the eurythermal cuttlefish Sepia officinalis was analyzed by continuous and simultaneous recordings of changes in pH and hemocyanin oxygen saturation in whole blood at various temperatures. These data were compared to literature data on other temperate and cold-water cephalopods (octopods and giant squid). In S. officinalis, the oxygen affinity of hemocyanin changed at deltaP50/degrees C = 0.12 kPa (pH 7.4) with increasing temperatures; this is similar to observations in temperate octopods. In M. senoi, thermal sensitivity was much smaller (delta log P50/delta pH) increased with increasing temperature in both the cuttlefish and the Antarctic octopod. At low PO2 (1.0 kPa) and pH (7.2), the presence of a large venous oxygen reserve (43% saturation) insensitive to pH reflects reduced pH sensitivity and high oxygen affinity in M. senoi hemocyanin at 0 degrees C. In S. officinalis, this reserve was 19% at pH 7.4, 20 degrees C, and 1.7 kPa O2, a level still higher than in squid. These findings suggest that the lower metabolic rate of octopods and cuttlefish compared to squid is reflected in less pH-dependent oxygen transport. Results of the hemocyanin analysis for the Antarctic octopod were similar to those reported for Vampyroteuthis--an extremely high oxygen affinity supporting a very low metabolic rate. In contrast to findings in cold-adapted giant squid, the minimized thermal sensitivity of oxygen transport in Antarctic octopods will reduce metabolic scope and thereby contribute to their stenothermality.

  6. Influence of the depth of sedation on regional cerebral oxygen saturation monitoring in neurosurgery of supratentorial gliomas

    Directory of Open Access Journals (Sweden)

    ZHANG Kai⁃ying

    2012-12-01

    Full Text Available Objective To investigate the influence on regional cerebral oxygen saturation (rScO2 of sedation depth during anesthesia induction and maintenance in supratentorial glioma resections. Methods Thirty patients with Ⅰ - Ⅱ supratentorial glioma (graded by American Society of Anesthesiologists underwent elective supratentorial glioma resection were included in this study. Rocuronium, sufentanil and propofol were used for anesthesia induction. After trachea cannula, total intravenous anesthesia (TIVA was maintained with plasma concentration of propofol 2.80-3.20 μg/ml and remifentanil 0.10-0.20 μg/(kg·min. Thirty groups of rScO2, bispectral index (BIS, mean arterial pressure (MAP and heart rate (HR were recorded continuously till the incision. Results During anesthesia induction, BIS decreased along with the infusion of anesthetics, and there was significant negative correlation between BIS and rScO2 (r = ⁃0.803, P = 0.001. During anesthesia maintenance, rScO2 and BIS were not significantly related (r = 0.147, P = 0.396. Conclusion The rScO2 monitoring can reflect the influence of sedation depth on cerebral oxygen delivery and consumption balance during supratentorial glioma resection under TIVA.

  7. Preliminary Study of Oxygen-Enhanced Longitudinal Relaxation in MRI: A Potential Novel Biomarker of Oxygenation Changes in Solid Tumors

    International Nuclear Information System (INIS)

    O'Connor, James P.B.; Naish, Josephine H.; Parker, Geoff J.M.; Waterton, John C.; Watson, Yvonne; Jayson, Gordon C.; Buonaccorsi, Giovanni A.; Cheung, Sue; Buckley, David L.; McGrath, Deirdre M.; West, Catharine M.L.; Davidson, Susan E.; Roberts, Caleb; Mills, Samantha J.; Mitchell, Claire L.; Hope, Lynn; Ton, N. Chan; Jackson, Alan

    2009-01-01

    Purpose: There is considerable interest in developing non-invasive methods of mapping tumor hypoxia. Changes in tissue oxygen concentration produce proportional changes in the magnetic resonance imaging (MRI) longitudinal relaxation rate (R 1 ). This technique has been used previously to evaluate oxygen delivery to healthy tissues and is distinct from blood oxygenation level-dependent (BOLD) imaging. Here we report application of this method to detect alteration in tumor oxygenation status. Methods and materials: Ten patients with advanced cancer of the abdomen and pelvis underwent serial measurement of tumor R 1 while breathing medical air (21% oxygen) followed by 100% oxygen (oxygen-enhanced MRI). Gadolinium-based dynamic contrast-enhanced MRI was then performed to compare the spatial distribution of perfusion with that of oxygen-induced ΔR 1 . Results: ΔR 1 showed significant increases of 0.021 to 0.058 s -1 in eight patients with either locally recurrent tumor from cervical and hepatocellular carcinomas or metastases from ovarian and colorectal carcinomas. In general, there was congruency between perfusion and oxygen concentration. However, regional mismatch was observed in some tumor cores. Here, moderate gadolinium uptake (consistent with moderate perfusion) was associated with low area under the ΔR 1 curve (consistent with minimal increase in oxygen concentration). Conclusions: These results provide evidence that oxygen-enhanced longitudinal relaxation can monitor changes in tumor oxygen concentration. The technique shows promise in identifying hypoxic regions within tumors and may enable spatial mapping of change in tumor oxygen concentration.

  8. Dual-wavelength photothermal optical coherence tomography for blood oxygen saturation measurement

    Science.gov (United States)

    Yin, Biwei; Kuranov, Roman V.; McElroy, Austin B.; Milner, Thomas E.

    2013-03-01

    We report design and demonstration of a dual wavelength photothermal (DWP) optical coherence tomography (OCT) system for imaging of a phantom microvessel and measurement of hemoglobin oxygen saturation (SO2) level. The DWP-OCT system contains a swept-source (SS) two-beam phase-sensitive (PhS) OCT system (1060 nm) and two intensity modulated photothermal excitation lasers (770 nm and 800 nm). The PhS-OCT probe beam (1060 nm) and photothermal excitation beams are combined into one single-mode optical fiber. A galvanometer based two-dimensional achromatic scanning system is designed to provide 14 μm lateral resolution for the PhS-OCT probe beam (1060 nm) and 13 μm lateral resolution for photothermal excitation beams. DWP-OCT system's sensitivity is 102 dB, axial resolution is 13 μm in tissue and uses a real-time digital dispersion compensation algorithm. Noise floor for optical pathlength measurements is 300 pm in the signal frequency range (380-400 Hz) of photothermal modulation frequencies. Blood SO2 level is calculated from measured optical pathlength (op) signal in a 300 μm diameter microvessel phantom introduced by the two photothermal excitation beams. En-face and B-scan images of a phantom microvessel are recorded, and six blood samples' SO2 levels are measured using DWP-OCT and compared with values provided by a commercial blood oximeter. A mathematical model indicates thermal diffusion introduces a systematic artifact that over-estimates SO2 values and is consistent with measured data.

  9. Relationship between intraoperative regional cerebral oxygen saturation trends and cognitive decline after total knee replacement: a post-hoc analysis.

    Science.gov (United States)

    Salazar, Fátima; Doñate, Marta; Boget, Teresa; Bogdanovich, Ana; Basora, Misericordia; Torres, Ferran; Gracia, Isabel; Fàbregas, Neus

    2014-01-01

    Bilateral regional brain oxygen saturation (rSO2) trends, reflecting intraoperative brain oxygen imbalance, could warn of brain dysfunction. Various types of cognitive impairment, such as memory decline, alterations in executive function or subjective complaints, have been described three months after surgery. Our aim was to explore the potential utility of rSO2 values as a warning sign for the development of different types of decline in postoperative psychological function. Observational post-hoc analysis of data for the patient sample (n = 125) of a previously conducted clinical trial in patients over the age of 65 years undergoing total knee replacement under spinal anesthesia. Demographic, hemodynamic and bilateral rSO2 intraoperative values were recorded. An absolute rSO2 value of 20% or >25% below baseline were chosen as relevant cutoffs. Composite function test scores were created from baseline to three months for each patient and adjusted for the mean (SD) score changes for a control group (n = 55). Tests were used to assess visual-motor coordination and executive function (VM-EF) (Wechsler Digit Symbol-Coding and Visual Reproduction, Trail Making Test) and memory (Auditory Verbal Learning, Wechsler Memory Scale); scales were used to assess psychological symptoms. We observed no differences in baseline rSO2 values; rSO2 decreased significantly in all patients during surgery (P Left and right rSO2 values were asymmetric in patients who had memory decline (mean [SD] left-right ratio of 95.03 [8.51] vs 101.29 [6.7] for patients with no changes, P = 0.0012). The mean right-left difference in rSO2 was also significant in these patients (-2.87% [4.73%], lower on the right, P = 0.0034). Detection of a trend to asymmetry in rSO2 values can warn of possible postoperative onset of memory decline. Psychological symptoms and memory decline were common three months after knee replacement in our patients over the age of 65 years.

  10. Cerebral time domain-NIRS: reproducibility analysis, optical properties, hemoglobin species and tissue oxygen saturation in a cohort of adult subjects.

    Science.gov (United States)

    Giacalone, Giacomo; Zanoletti, Marta; Contini, Davide; Re, Rebecca; Spinelli, Lorenzo; Roveri, Luisa; Torricelli, Alessandro

    2017-11-01

    The reproducibility of cerebral time-domain near-infrared spectroscopy (TD-NIRS) has not been investigated so far. Besides, reference intervals of cerebral optical properties, of absolute concentrations of deoxygenated-hemoglobin (HbR), oxygenated-hemoglobin (HbO), total hemoglobin (HbT) and tissue oxygen saturation (StO 2 ) and their variability have not been reported. We have addressed these issues on a sample of 88 adult healthy subjects. TD-NIRS measurements at 690, 785, 830 nm were fitted with the diffusion model for semi-infinite homogenous media. Reproducibility, performed on 3 measurements at 5 minutes intervals, ranges from 1.8 to 6.9% for each of the hemoglobin species. The mean ± SD global values of HbR, HbO, HbT, StO 2 are respectively 24 ± 7 μM, 33.3 ± 9.5 μM, 57.4 ± 15.8 μM, 58 ± 4.2%. StO 2 displays the narrowest range of variability across brain regions.

  11. Vagal activity and oxygen saturation response to hypoxia: Effects of aerobic fitness and rating of hypoxia tolerance

    Directory of Open Access Journals (Sweden)

    Tomáš Macoun

    2017-10-01

    Full Text Available Background: A reduction in the inspired oxygen fraction (FiO2 induces a decline in arterial oxygen saturation (SpO2 and changes of heart rate variability (HRV. It has been shown that SpO2 and HRV responses to similar levels of acute normobaric hypoxia are inter-individual variable. Variable response may be influenced by normoxia reached maximal oxygen uptake (VO2max value. Objective: The primary aim was to assess HRV and the SpO2 response to hypoxia, and examine the association with normoxic VO2max. Methods: Supine HRV and SpO2 were monitored during normobaric hypoxia (FiO2 = 9.6% for 10 minutes in 28 subjects, aged 23.7 ± 1.7 years. HRV was evaluated by using both spectral and time domain HRV analysis. Low frequency (LF, 0.05-0.15 Hz and high frequency (HF, 0.15-0.50 Hz power together with square root of the mean of the squares of the successive differences (rMSSD were calculated and transformed by natural logarithm (Ln. Based on the SpO2 in hypoxia, subjects were divided into Resistant (RG, SpO2 ≥ 70.9%, n = 14 and Sensitive (SG, SpO2 < 70.9%, n = 14 groups. Perceived hypoxia tolerance was self-scored on a 4-level scale. Results: VO2max was higher in SG (62.4 ± 7.2 ml ⋅ kg-1 ⋅ min-1 compared with RG (55.5 ± 7.1 ml ⋅ kg-1 ⋅ min-1, p = .017, d = 0.97. A significant relationship (r = -.45, p = .017 between hypoxic-normoxic difference in SpO2 and normoxic VO2max level was found. Vagal activity (Ln rMSSD was significantly decreased (SG: p < .001, d = 2.64; RG: p < .001, d = 1.22, while sympathetic activity (Ln LF/HF was relatively increased (p < .001, d = -1.40 in only the SG during hypoxia. Conclusions: Results show that subjects with a higher aerobic capacity exhibited a greater decline in SpO2, accompanied by greater autonomic cardiac disturbances during hypoxia. The SpO2 reduction was associated with perceived hypoxia comfort/discomfort. The hypoxia

  12. Corrosion behavior of austenitic and ferritic/martensitic steels in oxygen-saturated liquid Pb-Bi eutectic at 450circC and 550circC

    OpenAIRE

    倉田 有司; 二川 正敏; 斎藤 滋

    2005-01-01

    Static corrosion tests of various austenitic and ferritic/martensitic steels were conducted in oxygen-saturated liquid Pb-Bi at 450circC and 550circC for 3000h to study the effects of temperature and alloying elements on corrosion behavior. Oxidation, grain boundary corrosion, dissolution and penetration were observed. The corrosion depth decreases at 450circC with increasing Cr content in steels regardless of ferritic/martensitic or austenitic steels. Appreciable dissolution of Ni and Cr doe...

  13. The human ear canal: investigation of its suitability for monitoring photoplethysmographs and arterial oxygen saturation

    International Nuclear Information System (INIS)

    Budidha, K; Kyriacou, P A

    2014-01-01

    For the last two decades, pulse oximetry has been used as a standard procedure for monitoring arterial oxygen saturation (SpO 2 ). However, SpO 2 measurements made from extremities such as the finger, ear lobe and toes become susceptible to inaccuracies when peripheral perfusion is compromised. To overcome these limitations, the external auditory canal has been proposed as an alternative monitoring site for estimating SpO 2 , on the hypothesis that this central site will be better perfused. Therefore, a dual wavelength optoelectronic probe along with a processing system was developed to investigate the suitability of measuring photoplethysmographic (PPG) signals and SpO 2 in the human auditory canal. A pilot study was carried out in 15 healthy volunteers to validate the feasibility of measuring PPGs and SpO 2  from the ear canal (EC), and comparative studies were performed by acquiring the same signals from the left index finger (LIF) and the right index finger (RIF) in conditions of induced peripheral vasoconstriction (right hand immersion in ice water). Good quality baseline PPG signals with high signal-to-noise ratio were obtained from the EC, the LIF and the RIF sensors. During the ice water immersion, significant differences in the amplitude of the red and infrared PPG signals were observed from the RIF and the LIF sensors. The average drop in amplitude of red and infrared PPG signals from the RIF was 52.7% and 58.3%. Similarly, the LIF PPG signal amplitudes have reduced by 47.52% and 46.8% respectively. In contrast, no significant changes were seen in the red and infrared EC PPG amplitude measurements, which changed by +2.5% and −1.2% respectively. The RIF and LIF pulse oximeters have failed to estimate accurate SpO 2  in seven and four volunteers respectively, while the EC pulse oximeter has only failed in one volunteer. These results suggest that the EC may be a suitable site for reliable monitoring of PPGs and SpO 2 s even in the presence of

  14. Theoretical model for optical oximetry at the capillary level: exploring hemoglobin oxygen saturation through backscattering of single red blood cells

    Science.gov (United States)

    Liu, Rongrong; Spicer, Graham; Chen, Siyu; Zhang, Hao F.; Yi, Ji; Backman, Vadim

    2017-02-01

    Oxygen saturation (sO2) of red blood cells (RBCs) in capillaries can indirectly assess local tissue oxygenation and metabolic function. For example, the altered retinal oxygenation in diabetic retinopathy and local hypoxia during tumor development in cancer are reflected by abnormal sO2 of local capillary networks. However, it is far from clear whether accurate label-free optical oximetry (i.e., measuring hemoglobin sO2) is feasible from dispersed RBCs at the single capillary level. The sO2-dependent hemoglobin absorption contrast present in optical scattering signal is complicated by geometry-dependent scattering from RBCs. We present a numerical study of backscattering spectra from single RBCs based on the first-order Born approximation, considering practical factors: RBC orientations, size variation, and deformations. We show that the oscillatory spectral behavior of RBC geometries is smoothed by variations in cell size and orientation, resulting in clear sO2-dependent spectral contrast. In addition, this spectral contrast persists with different mean cellular hemoglobin content and different deformations of RBCs. This study shows for the first time the feasibility of, and provides a theoretical model for, label-free optical oximetry at the single capillary level using backscattering-based imaging modalities, challenging the popular view that such measurements are impossible at the single capillary level.

  15. Pilot study assessment of dynamic vascular changes in breast cancer with near-infrared tomography from prospectively targeted manipulations of inspired end-tidal partial pressure of oxygen and carbon dioxide.

    Science.gov (United States)

    Jiang, Shudong; Pogue, Brian W; Michaelsen, Kelly E; Jermyn, Michael; Mastanduno, Michael A; Frazee, Tracy E; Kaufman, Peter A; Paulsen, Keith D

    2013-07-01

    The dynamic vascular changes in the breast resulting from manipulation of both inspired end-tidal partial pressure of oxygen and carbon dioxide were imaged using a 30 s per frame frequency-domain near-infrared spectral (NIRS) tomography system. By analyzing the images from five subjects with asymptomatic mammography under different inspired gas stimulation sequences, the mixture that maximized tissue vascular and oxygenation changes was established. These results indicate maximum changes in deoxy-hemoglobin, oxygen saturation, and total hemoglobin of 21, 9, and 3%, respectively. Using this inspired gas manipulation sequence, an individual case study of a subject with locally advanced breast cancer undergoing neoadjuvant chemotherapy (NAC) was analyzed. Dynamic NIRS imaging was performed at different time points during treatment. The maximum tumor dynamic changes in deoxy-hemoglobin increased from less than 7% at cycle 1, day 5 (C1, D5) to 17% at (C1, D28), which indicated a complete response to NAC early during treatment and was subsequently confirmed pathologically at the time of surgery.

  16. Oxygen-induced restructuring with release of gold atoms from Au(111)

    International Nuclear Information System (INIS)

    Min, B.K.; Deng, X.; Schalek, R.; Pinnaduwage, D.; Friend, C.M.

    2005-01-01

    Adsorption of oxygen atoms, achieved via electron-induced dissociation of nitrogen dioxide, induces restructuring of the 'herringbone' to a striped, soliton-wall structure accompanied by release of gold from the 'elbows' in the herringbone structure. The number density of 'elbows' (dislocations corresponding to a change in direction of the reconstruction) decreases as a function of increasing atomic oxygen coverage while the long range order observed in low energy electron diffraction (LEED) changes from (√(3)x22)-rec. to (1x22) in the limit of saturation coverage. Small islands and serrated step edges were formed due to the release of gold atoms from elbow sites of Au(111). The overall structural change of the Au(111) surface may result from the reduction of anisotropy related to the tensile stress relief of the Au(111) surface by oxygen atoms

  17. Simultaneous estimation of arterial and venous oxygen saturation using a camera

    Science.gov (United States)

    van Gastel, Mark; Liang, Hangbing; Stuijk, Sander; de Haan, Gerard

    2018-02-01

    Optical monitoring of arterial blood oxygenation, SpO2, using cameras has recently been shown feasible by measuring the relative amplitudes of the remotely sensed PPG waveforms captured at different wavelengths. SvO2 measures the venous blood oxygenation which together with SpO2 provides an indication of tissue oxygen consumption. In contrast to SpO2 it usually still requires a blood sample from a pulmonary artery catheter. In this work we present a method which suggests simultaneous estimation of SpO2 and SvO2 with a camera. Contrary to earlier work, our method does not require external cuffs leading to better usability and improved comfort. Since the arterial blood varies synchronously with the heart rate, all frequencies outside the heart rate band are typically filtered out for SpO2 measurements. For SvO2 estimation, we include intensity variations in the respiratory frequency range since respiration modulates venous blood due to intrathoracic pressure variations in the chest and abdomen. Consequently, under static conditions, the two dominant components in the PPG signals are respiration and pulse. By measuring the amplitude ratios of these components, it seems possible to monitor both SpO2 and SvO2 continuously. We asked healthy subjects to follow an auditory breathing pattern while recording the face and hand. Results show a difference in estimated SpO2 and SvO2 values in the range 5-30 percent for both anatomical locations, which is normal for healthy people. This continuous, non-contact, method shows promise to alert the clinician to a change in patient condition sooner than SpO2 alone.

  18. Low oxygen saturation and severe anemia in compound heterozygous Hb Louisville [β42(CD1)Phe→Leu] and Hb La Desirade [β129(H7)Ala→Val].

    Science.gov (United States)

    Kamseng, Parin; Trakulsrichai, Satariya; Trachoo, Objoon; Yimniam, Walaiporn; Panthan, Bhakbhoom; Jittorntam, Paisan; Niparuck, Pimjai; Sanguanwit, Pitsucha; Wananukul, Winai; Jindadamrongwech, Sumalee

    2017-03-01

    To investigate the cause(s) of a Thai male proband presenting low oxygen saturation by pulse oximetry (SpO 2 ) and severe anemia. As Hb variant was suspected, Hb typing was determined by high-performance liquid chromatography and capillary electrophoresis, and subsequently Hb variant was identified by DNA sequencing. Complete blood counts were performed using automated blood cell counter and oxygen saturation was measured by pulse oximetry. Proband was compound heterozygous for Hb Louisville [β42(CD1)Phe→Leu] and Hb La Desirade [β129(H7)Ala→Val]. Of the proband's two sons, one was compound heterozygous for Hb Louisville and Hb E and the other for Hb La Desirade and Hb E. The former son had similar clinical features and laboratory findings with those of the proband while the latter showed had no abnormal clinical manifestations. This the first report of compound heterozygosity of Hb Louisville and Hb La Desirade in an individual of Southeast Asian ethnicity. Hb variant identification is crucial for genetic counseling and appropriate treatment in regions where hemoglobinopathies are common.

  19. Corrosion Resistance of Steels and Armco-Fe in Lead Melt Saturated by Oxygen at 550 degree C

    International Nuclear Information System (INIS)

    Tsisar, V.P.; Fedirko, V.N.; Eliseeva, O.I.

    2007-01-01

    Corrosion resistance of stainless steels and Armco-Fe in static lead melt saturated by oxygen at 550 degree C for 2000 h was investigated. It was determined that double oxide layer was formed on the surface of investigated materials. Outer part of double oxide growths from the initial interface 'solid metal/liquid lead' towards the melt and consists of Fe 3 O 4 . Inner part of double oxide based on the matrix is composed of Fe 3 O 4 for Armco-Fe, Fe 1+x Cr 2-x O 4 for martensitic 0.2 C-13 Cr and ferritic-martensitic EP823 steels and Fe 1+x Cr 2- xO 4 +Ni for austenitic 18Cr-10Ni-1Ti. Lead did not penetrate into the matrix of tested materials and was detected only in the scale formed on austenitic steel

  20. Future changes in the Baltic Sea acid–base (pH and oxygen balances

    Directory of Open Access Journals (Sweden)

    Anders Omstedt

    2012-12-01

    Full Text Available Possible future changes in Baltic Sea acid–base (pH and oxygen balances were studied using a catchment–sea coupled model system and numerical experiments based on meteorological and hydrological forcing datasets and scenarios. By using objective statistical methods, climate runs for present climate conditions were examined and evaluated using Baltic Sea modelling. The results indicate that increased nutrient loads will not inhibit future Baltic Sea acidification; instead, the seasonal pH cycle will be amplified by increased biological production and mineralization. All examined scenarios indicate future acidification of the whole Baltic Sea that is insensitive to the chosen global climate model. The main factor controlling the direction and magnitude of future pH changes is atmospheric CO2 concentration (i.e. emissions. Climate change and land-derived changes (e.g. nutrient loads affect acidification mainly by altering the seasonal cycle and deep-water conditions. Apart from decreasing pH, we also project a decreased saturation state of calcium carbonate, decreased respiration index and increasing hypoxic area – all factors that will threaten the marine ecosystem. We demonstrate that substantial reductions in fossil-fuel burning are needed to minimise the coming pH decrease and that substantial reductions in nutrient loads are needed to reduce the coming increase in hypoxic and anoxic waters.

  1. LOW OXYGENATION STATUS INCREASES NAUSEA-VOMITING INCIDENCE IN HEMODIALYSIS PATIENTS

    Directory of Open Access Journals (Sweden)

    Cornelia DY Nekada

    2017-08-01

    Full Text Available Background and Objective: Data from Indonesia Basic Health Research (2013 states that the chronic renal failure in Indonesia is increasing, especially in Yogyakarta with the prevalence of chronic renal failure of 0,3%. If the patients of chronic renal failure are in End Stage Renal Disease (ESRD, the kidney needs replacement therapy to help its function. This therapy is called Continuous Renal Replacement Therapy (CRRT or Hemodialysis (HD. Hemodialysis therapy may influence to the imbalance of oxyhemoglobin in the blood. Patients undergoing hemodialysis may experience intradialytic nausea and vomiting. The objective of this study is to identify whether there is a relationship between pre-dialysis oxygenation status through oxygen saturation (SpO2 and respiratory rate (RR examination and the intradialytic nausea-vomiting occurrence. Method: This research is a comparative research with analytical cross sectional design. This research was conducted in hemodialysis room in Public Hospital of Panembahan Senopati Bantul. The subject of the research was taken using total sampling, by paying attention to research ethics. The total research subjects are 183 respondents. The researchers measured the oxygen saturation and patients’ respiratory rate and examined the intradialytic nausea and vomiting complaints. Result: The analysis result of Fisher’s exact in this research shows p value of 0,000 both in bivariate analysis of oxygen saturation to the nausea and vomiting occurrence and in bivariate analysis of the respiratory rate to the nausea and vomiting occurrence. The multivariate analysis employing regression logistic shows that the OR of oxygen saturation is 73,57, this means that the measurement of the abnormal oxygen saturation has the chance of seventy three times more to the nausea and vomiting occurrence, if compared to the patients with normal oxygen saturation. Conclusion and Suggestion: Intradialytic nausea and vomiting is one of the causes

  2. Effects of divided attention and operating room noise on perception of pulse oximeter pitch changes: a laboratory study.

    Science.gov (United States)

    Stevenson, Ryan A; Schlesinger, Joseph J; Wallace, Mark T

    2013-02-01

    Anesthesiology requires performing visually oriented procedures while monitoring auditory information about a patient's vital signs. A concern in operating room environments is the amount of competing information and the effects that divided attention has on patient monitoring, such as detecting auditory changes in arterial oxygen saturation via pulse oximetry. The authors measured the impact of visual attentional load and auditory background noise on the ability of anesthesia residents to monitor the pulse oximeter auditory display in a laboratory setting. Accuracies and response times were recorded reflecting anesthesiologists' abilities to detect changes in oxygen saturation across three levels of visual attention in quiet and with noise. Results show that visual attentional load substantially affects the ability to detect changes in oxygen saturation concentrations conveyed by auditory cues signaling 99 and 98% saturation. These effects are compounded by auditory noise, up to a 17% decline in performance. These deficits are seen in the ability to accurately detect a change in oxygen saturation and in speed of response. Most anesthesia accidents are initiated by small errors that cascade into serious events. Lack of monitor vigilance and inattention are two of the more commonly cited factors. Reducing such errors is thus a priority for improving patient safety. Specifically, efforts to reduce distractors and decrease background noise should be considered during induction and emergence, periods of especially high risk, when anesthesiologists has to attend to many tasks and are thus susceptible to error.

  3. Effects of divided attention and operating room noise on perception of pulse oximeter pitch changes: A laboratory study

    Science.gov (United States)

    Stevenson, Ryan A.; Fellow, Postdoctoral; Schlesinger, Joseph J.; Physician, Resident; Wallace, Mark T.

    2012-01-01

    Background Anesthesiology requires performing visually-oriented procedures while monitoring auditory information about a patient’s vital signs. A concern in operating rooms environments is the amount of competing information and the effects that divided attention have on patient monitoring, such as detecting auditory changes in arterial oxygen saturation via pulse oximetry. Methods We measured the impact of visual attentional load and auditory background noise on the ability of anesthesia residents to monitor the pulse oximeter auditory display in a laboratory setting. Accuracies and response times were recorded reflecting anesthesiologists’ abilities to detect changes in oxygen saturation across three levels of visual attention in quiet and with noise. Results Results show that visual attentional load substantially impacts the ability to detect changes in oxygen saturation levels conveyed by auditory cues signaling 99 and 98% saturation. These effects are compounded by auditory noise, with up to a 17% decline in performance. These deficits are seen in the ability to accurately detect a change in oxygen saturation and in speed of response. Conclusions Most anesthesia accidents are initiated by small errors that cascade into serious events. Lack of monitor vigilance and inattention are two of the more commonly cited factors. Reducing such errors is thus a priority for improving patient safety. Specifically, efforts to reduce distractors and lower background noise should be considered during induction and emergence, periods of especially high risk, when anesthesiologists must attend to many tasks and are thus susceptible to error. PMID:23263015

  4. Oxygen Concentration Inside a Functioning Photosynthetic Cell

    OpenAIRE

    Kihara, Shigeharu; Hartzler, Daniel A.; Savikhin, Sergei

    2014-01-01

    The excess oxygen concentration in the photosynthetic membranes of functioning oxygenic photosynthetic cells was estimated using classical diffusion theory combined with experimental data on oxygen production rates of cyanobacterial cells. The excess oxygen concentration within the plesiomorphic cyanobacterium Gloeobactor violaceus is only 0.025 μM, or four orders of magnitude lower than the oxygen concentration in air-saturated water. Such a low concentration suggests that the first oxygenic...

  5. Functional magnetic resonance imaging (fMRI) for fetal oxygenation during maternal hypoxia: initial results

    International Nuclear Information System (INIS)

    Wedegaertner, U.; Adam, G.; Tchirikov, M.; Schroeder, H.; Koch, M.

    2002-01-01

    Purpose: To investigate the potential of fMRI to measure changes in fetal tissue oxygenation during acute maternal hypoxia in fetal lambs. Material and Methods: Two ewes carrying singleton fetuses (gestational age 125 and 131 days) underwent MR imaging under inhalation anesthesia. BOLD imaging of the fetal brain, liver and myocardium was performed during acute maternal hypoxia (oxygen replaced by N 2 O). Maternal oxygen saturation and heart rate were monitored by a pulse-oxymeter attached to the maternal tongue. Results: Changes of fetal tissue oxygenation during maternal hypoxia were clearly visible with BOLD MRI. Signal intensity decreases were more distinct in liver and heart (∝40%) from control than in the fetal brain (∝10%). Conclusions: fMRI is a promising diagnostic tool to determine fetal tissue oxygenation and may open new opportunities in monitoring fetal well being in high risk pregnancies complicated by uteroplacentar insufficiency. Different signal changes in liver/heart and brain may reflect a centralization of the fetal blood flow. (orig.) [de

  6. Hemodynamic and oxygenation changes in surgical intensive care unit patients with fever and fever lowering nursing interventions.

    Science.gov (United States)

    Çelik, Sevim; Yildirim, Ismail; Arslan, Ibrahim; Yildirim, Sinan; Erdal, Fatih; Yandi, Yunus Emre

    2011-12-01

    The purpose of this study was to determine the effects of fever and nursing interventions to lower fever on hemodynamic values and oxygenation in febrile (temperature greater than 38.3°C) surgical intensive care unit patients. This retrospective study was conducted in 53 febrile patients out of 519 patients admitted to the surgical intensive care unit at a university hospital. Data were obtained from the medical records, laboratory files and nursing notes. Statistical analysis of the data was analyzed by repeated measures analysis of variance and a paired sample t-test. The average hourly urine output (F = 5.46; P = 0.002) and systolic blood pressure (F = 2.87; P = 0.03) were significantly lower after fever onset. Heart rate, respiratory rate, positive end-expiratory pressure settings and FiO(2) settings were unchanged after the development of fever. Diastolic blood pressure and oxygen saturation had non-statistically significant decreases. Nursing interventions for febrile patients consisted of medication administration (69.8%), ice (62.3%) and sponging with tepid water (62.3%). The present results showed that fever was associated with an increase in heart rate, decreased systolic arterial pressure, mean arterial pressure, oxygen saturation and hourly urine output. © 2011 Blackwell Publishing Asia Pty Ltd.

  7. Poincaré analysis of an overnight arterial oxygen saturation signal applied to the diagnosis of sleep apnea hypopnea syndrome

    International Nuclear Information System (INIS)

    Morillo, Daniel S; Rojas, Juan L; Crespo, Luis F; León, Antonio; Gross, Nicole

    2009-01-01

    The analysis of oxygen desaturations is a basic variable in polysomnographic studies for the diagnosis of sleep apnea. Several algorithms operating in the time domain already exist for sleep apnea detection via pulse oximetry, but in a disadvantageous way—they achieve either a high sensitivity or a high specificity. The aim of this study was to assess whether an alternative analysis of arterial oxygen saturation (SaO 2 ) signals from overnight pulse oximetry could yield essential information on the diagnosis of sleep apnea hypopnea syndrome (SAHS). SaO 2 signals from 117 subjects were analyzed. The population was divided into a learning dataset (70 patients) and a test set (47 patients). The learning set was used for tuning thresholds among the applied Poincaré quantitative descriptors. Results showed that the presence of apnea events in SAHS patients caused an increase in the SD 1 Poincaré parameter. This conclusion was assessed prospectively using the test dataset. 90.9% sensitivity and 84.0% specificity were obtained in the test group. We conclude that Poincaré analysis could be useful in the study of SAHS, contributing to reduce the demand for polysomnographic studies in SAHS screening

  8. Singlet oxygen quenching by oxygen in tetraphenyl-porphyrin solutions

    International Nuclear Information System (INIS)

    Dedic, Roman; Korinek, Miloslav; Molnar, Alexander; Svoboda, Antonin; Hala, Jan

    2006-01-01

    Time-resolved measurement of singlet oxygen infrared phosphorescence is a powerful tool for determination of quantum yields and kinetics of its photosensitization. This technique was employed to investigate in detail the previously observed effect of singlet oxygen quenching by oxygen. The question whether the singlet oxygen is quenched by oxygen in ground or in excited state was addressed by study of two complementary dependencies of singlet oxygen lifetimes: on dissolved oxygen concentration and on excitation intensity. Oxygen concentration dependence study of meso-tetra(4-sulphonato)phenylporphyrin (TPPS 4 ) phosphorescence kinetics showed linearity of the dependence of TPPS 4 triplet state rate-constant. Corresponding bimolecular quenching constant of (1.5±0.1)x10 9 l/mol s was obtained. On the other hand, rate constants of singlet oxygen depopulation exhibit nonlinear dependence on oxygen concentration. Comparison of zero oxygen concentration-extrapolated value of singlet oxygen lifetime of (6.5±0.4) μs to (3.7±0.1) μs observed under air-saturated conditions indicates importance of the effect of quenching of singlet oxygen by oxygen. Upward-sloping dependencies of singlet oxygen depopulation rate-constant on excitation intensity evidence that singlet oxygen is predominantly quenched by oxygen in excited singlet state

  9. Monitoring hemodynamics and oxygenation of the kidney in rats by a combined near-infrared spectroscopy and invasive probe approach

    Science.gov (United States)

    Grosenick, Dirk; Cantow, Kathleen; Arakelyan, Karen; Wabnitz, Heidrun; Flemming, Bert; Skalweit, Angela; Ladwig, Mechthild; Macdonald, Rainer; Niendorf, Thoralf; Seeliger, Erdmann

    2015-07-01

    We have developed a hybrid approach to investigate the dynamics of perfusion and oxygenation in the kidney of rats under pathophysiologically relevant conditions. Our approach combines near-infrared spectroscopy to quantify hemoglobin concentration and oxygen saturation in the renal cortex, and an invasive probe method for measuring total renal blood flow by an ultrasonic probe, perfusion by laser-Doppler fluxmetry, and tissue oxygen tension via fluorescence quenching. Hemoglobin concentration and oxygen saturation were determined from experimental data by a Monte Carlo model. The hybrid approach was applied to investigate and compare temporal changes during several types of interventions such as arterial and venous occlusions, as well as hyperoxia, hypoxia and hypercapnia induced by different mixtures of the inspired gas. The approach was also applied to study the effects of the x-ray contrast medium iodixanol on the kidney.

  10. Analysis of a microscale 'Saturation Phase-change Internal Carnot Engine'

    International Nuclear Information System (INIS)

    Lurie, Eli; Kribus, Abraham

    2010-01-01

    A micro heat engine, based on a cavity filled with a stationary working fluid under liquid-vapor saturation conditions and encapsulated by two membranes, is described and analyzed. This engine design is easy to produce using MEMS technologies and is operated with external heating and cooling. The motion of the membranes is controlled such that the internal pressure and temperature are constant during the heat addition and removal processes, and thus the fluid executes a true internal Carnot cycle. A model of this Saturation Phase-change Internal Carnot Engine (SPICE) was developed including thermodynamic, mechanical and heat transfer aspects. The efficiency and maximum power of the engine are derived. The maximum power point is fixed in a three-parameter space, and operation at this point leads to maximum power density that scales with the inverse square of the engine dimension. Inclusion of the finite heat capacity of the engine wall leads to a strong dependence of performance on engine frequency, and the existence of an optimal frequency. Effects of transient reverse heat flow, and 'parasitic heat' that does not participate in the thermodynamic cycle are observed.

  11. On the importance of prompt oxygen changes for hypofractionated radiation treatments

    International Nuclear Information System (INIS)

    Kissick, Michael; Campos, David; Van der Kogel, Albert; Kimple, Randall

    2013-01-01

    This discussion is motivated by observations of prompt oxygen changes occurring prior to a significant number of cancer cells dying (permanently stopping their metabolic activity) from therapeutic agents like large doses of ionizing radiation. Such changes must be from changes in the vasculature that supplies the tissue or from the metabolic changes in the tissue itself. An adapted linear–quadratic treatment is used to estimate the cell survival variation magnitudes from repair and reoxygenation from a two-fraction treatment in which the second fraction would happen prior to significant cell death from the first fraction, in the large fraction limit. It is clear the effects of oxygen changes are likely to be the most significant factor for hypofractionation because of large radiation doses. It is a larger effect than repair. Optimal dose timing should be determined by the peak oxygen timing. A call is made to prioritize near real time measurements of oxygen dynamics in tumors undergoing hypofractionated treatments in order to make these treatments adaptable and patient-specific. (note)

  12. Oxygen requirement of separated hybrid catfish eggs

    Science.gov (United States)

    Channel catfish egg masses require hatchery water with over 7.8 ppm dissolved oxygen at 80° F (95% air saturation) to maintain maximum oxygen consumption as they near hatching. This concentration is called the critical oxygen requirement by scientists but for the purpose of this article we will call...

  13. Oxygen incorporation into GST phase-change memory matrix

    Energy Technology Data Exchange (ETDEWEB)

    Golovchak, R., E-mail: holovchakr@apsu.edu [Department of Physics and Astronomy, Austin Peay State University, Clarksville, TN 37044 (United States); Choi, Y.G. [Department of Materials Science and Engineering, Korea Aerospace University, Gyeonggi 412-791 (Korea, Republic of); Kozyukhin, S. [Kurnakov Institute of General and Inorganic Chemistry of RAS, 31 Leninsky Pr., Moscow 119991 (Russian Federation); National Research Tomsk State University, 36 Lenin Pr., Tomsk 634050 (Russian Federation); Chigirinsky, Yu. [Scientific-Research Physicotechnical Institute at the Nizhnii Novgorod State University, Nizhnii Novgorod 603600 (Russian Federation); Kovalskiy, A.; Xiong-Skiba, P.; Trimble, J. [Department of Physics and Astronomy, Austin Peay State University, Clarksville, TN 37044 (United States); Pafchek, R.; Jain, H. [Department of Materials Science and Engineering, Lehigh University, 5 East Packer Avenue, Bethlehem, PA 18015-3195 (United States)

    2015-03-30

    Graphical abstract: - Highlights: • Surfaces of GST-225 films are depleted in Te as a result of the reaction with oxygen. • Top layers of oxidized GST-225 are formed by Sb and Ge oxide complexes. • Depth profiles of Sb and Ge oxide complexes are found to be different. • Crystallization at 300 °C in O{sub 2} atmosphere leads to Ge redistribution. - Abstract: Structural changes in amorphous and crystallized GST-225 films induced by the reaction with oxygen are studied at different depth scales. The mechanism of interaction of the very top surface layers with oxygen is studied with low-energy ion scattering (LEIS) technique, while the modifications of chemistry in the underlying surface layers are investigated with high-resolution X-ray photoelectron spectroscopy (XPS). The changes averaged through the overall film thickness are characterized by micro-Raman spectroscopy. The oxygen exposure leads to a depletion of GST-225 film surfaces in Te and formation of the antimony and germanium oxides. The antimony oxide complexes are found throughout the whole thickness of the films after their prolonged storage in air, whereas no evidence for formation of pure GeO{sub 2} phase is found in the volume of the films through Raman spectroscopy. A tendency to form Ge-rich phase within the ∼10 nm surface layer is additionally observed by LEIS profiling during crystallization of GST-225 film at 300 °C in oxygen atmosphere.

  14. Sensitivity of ocean acidification and oxygen to the uncertainty in climate change

    International Nuclear Information System (INIS)

    Cao, Long; Wang, Shuangjing; Zheng, Meidi; Zhang, Han

    2014-01-01

    Due to increasing atmospheric CO 2 concentrations and associated climate change, the global ocean is undergoing substantial physical and biogeochemical changes. Among these, changes in ocean oxygen and carbonate chemistry have great implication for marine biota. There is considerable uncertainty in the projections of future climate change, and it is unclear how the uncertainty in climate change would also affect the projection of oxygen and carbonate chemistry. To investigate this issue, we use an Earth system model of intermediate complexity to perform a set of simulations, including that which involves no radiative effect of atmospheric CO 2 and those which involve CO 2 -induced climate change with climate sensitivity varying from 0.5 °C to 4.5 °C. Atmospheric CO 2 concentration is prescribed to follow RCP 8.5 pathway and its extensions. Climate change affects carbonate chemistry and oxygen mainly through its impact on ocean temperature, ocean ventilation, and concentration of dissolved inorganic carbon and alkalinity. It is found that climate change mitigates the decrease of carbonate ions at the ocean surface but has negligible effect on surface ocean pH. Averaged over the whole ocean, climate change acts to decrease oxygen concentration but mitigates the CO 2 -induced reduction of carbonate ion and pH. In our simulations, by year 2500, every degree increase of climate sensitivity warms the ocean by 0.8 °C and reduces ocean-mean dissolved oxygen concentration by 5.0%. Meanwhile, every degree increase of climate sensitivity buffers CO 2 -induced reduction in ocean-mean carbonate ion concentration and pH by 3.4% and 0.02 units, respectively. Our study demonstrates different sensitivities of ocean temperature, carbonate chemistry, and oxygen, in terms of both the sign and magnitude to the amount of climate change, which have great implications for understanding the response of ocean biota to climate change. (letters)

  15. The evaluation of cerebral oxygenation by oximetry in patients with ischaemic stroke.

    Directory of Open Access Journals (Sweden)

    Demet G

    2000-04-01

    Full Text Available AIMS: To evaluate the clinical significance of estimation of the regional cerebral oxygen saturation (rSO2 in the patients with ischaemic stroke by the cerebral oximetry during acute, sub-acute and chronic phases. SUBJECTS AND METHODS: In this prospective study, 24 patients with ischaemic stroke in the middle cerebral artery territory were included. A detailed clinical examination and appropriate laboratory investigations were carried out. The rSO2 was determined by oximetery (INVOS 3100-SD bilaterally on the first, third, seventh, and fifteenth days. The blood pressure, the peripheral capillary oxygen saturation and the arterial blood gas values were noted too. the changes were evaluated along with Glasgow coma scale (GCS using unpaired student t-test and one way ANOVA test. RESULTS: There were significant differences between the rSO2 values in acute, subacute and chronic phases on the side of the lesion (p value < 0.05. The values of oxygen saturation gradually increased throughout the chronic phase. These values showed a positive correlation with GCS, but the results were not significant statistically. The rSO2 values were also significantly higher on the non-lesional side than those on the lesion side in the acute phase (p= 0.0034, the discrepancy disappeared during the sub-acute and chronic phases. CONCLUSION: Cerebral oximetry can be used as a measure to evaluate the cerebral oxygenation during the various phases of ischaemic stroke. It has a potential to serve as a useful marker for detection of cerebral oxygenation imbalances, to judge the effectiveness of the management and for the follow-up of patients with ischaemic stroke.

  16. Oxygen and SO2 Consumption Rates in White and Rosé Wines: Relationship with and Effects on Wine Chemical Composition.

    Science.gov (United States)

    Carrascón, Vanesa; Bueno, Mónica; Fernandez-Zurbano, Purificación; Ferreira, Vicente

    2017-11-01

    This Article addresses the study of O 2 and SO 2 consumption rates of white and rosé wines, their relationship to the initial chemical composition, and their effects on the chemical changes experienced by wine during oxidation. Eight wines were subjected to five consecutive air-saturation cycles. O 2 was monitored periodically; SO 2 , color, and antioxidant indexes were determined after each cycle, and the initial and final compositions of the wines were thoroughly determined. Wines consumed oxygen at progressively decreasing rates. In the last cycles, after a strong decrease, consistent increases of oxygen levels were seen. Oxygen consumption rates were satisfactorily modeled, being proportional to wine copper, quercetin, and kaempherol contents and negatively proportional to cinnamic acids. SO 2 consumption rates were highly diverse between wines and were positively related to free SO 2 , Mn, and pH, among others. In the last saturations, SO 2 consumption took place regardless of O 2 consumption, implying that SO 2 should reduce chemical species oxidized in previous saturations. Some volatile phenols seem to be the end point of radical-mediated oxidation of polyphenols taking place preferably in the first saturation.

  17. Cutaneous Mitochondrial PO2, but Not Tissue Oxygen Saturation, Is an Early Indicator of the Physiologic Limit of Hemodilution in the Pig.

    Science.gov (United States)

    Römers, Luuk H L; Bakker, Charlotte; Dollée, Nathalie; Hoeks, Sanne E; Lima, Alexandre; Raat, Nicolaas J H; Johannes, Tanja; Stolker, Robert J; Mik, Egbert G

    2016-07-01

    Hemodilution is a consequence of fluid replacement during blood loss and is limited by the individual ability to compensate for decreasing hemoglobin level. We tested the ability of a novel noninvasive method for measuring cutaneous mitochondrial PO2 (mitoPO2) to detect this threshold early. Anesthetized and ventilated pigs were hemodynamically monitored and randomized into a hemodilution (n = 12) or a time control (TC) group (n = 14). MitoPO2 measurements were done by oxygen-dependent delayed fluorescence of protoporphyrin IX after preparation of the skin with 20% 5-aminolevulinic acid cream. Tissue oxygen saturation (StO2) was measured with near infrared spectroscopy on the thoracic wall. After baseline measurements, progressive normovolemic hemodilution was performed in the hemodilution group in equal steps (500 ml blood replaced by 500 ml Voluven; Fresenius Kabi AG, Germany). Consecutive measurements were performed after 20-min stabilization periods and repeated 8 times or until the animal died. The TC animals remained stable with regard to hemodynamics and mitoPO2. In the hemodilution group, mitoPO2 became hemoglobin-dependent after reaching a threshold of 2.6 ± 0.2 g/dl. During hemodilution, hemoglobin and mitoPO2 decreased (7.9 ± 0.2 to 2.1 ± 0.2 g/dl; 23.6 ± 2 to 9.9 ± 0.8 mmHg), but StO2 did not. Notably, mitoPO2 dropped quite abruptly (about 39%) at the individual threshold. We observed that this decrease in mitoPO2 occurred at least one hemodilution step before changes in other conventional parameters. Cutaneous mitoPO2 decreased typically one hemodilution step before occurrence of significant alterations in systemic oxygen consumption and lactate levels. This makes mitoPO2 a potential early indicator of the physiologic limit of hemodilution and possibly a physiologic trigger for blood transfusion.

  18. Society of cardiovascular anesthesiologists: the effect of blood pressure regulation during aortic coarctation repair on brain, kidney, and muscle oxygen saturation measured by near-infrared spectroscopy: a randomized, clinical trial

    NARCIS (Netherlands)

    Moerman, Annelies; Bové, Thierry; François, Katrien; Jacobs, Stefan; Deblaere, Isabel; Wouters, Patrick; de Hert, Stefan

    2013-01-01

    In this study, we compared the effects of 3 frequently used arterial blood pressure-regulating agents on brain (rScO2), renal (SrO2), and muscle (SmO2) oxygen saturation, during aortic coarctation repair in children. Based on the reported adverse effect of sodium nitroprusside (SNP) on left-sided

  19. Structural changes of polytetrafluoroethylene during irradiation in oxygen

    International Nuclear Information System (INIS)

    Liu, Shuling; Fu, Congli; Gu, Aiqun; Yu, Zili

    2015-01-01

    To study the effect of irradiation on PTFE structure and prepare modified PTFE micropowder, PTFE was irradiated with dose up to 4 MGy in oxygen at room temperature. The structures of both irradiated and unirradiated PTFE samples were comparatively characterized by IR, XPS, Raman spectra and XRD measurement. The results showed that new groups of acyl fluoride (COF), carboxylic acid (COOH) and trifluoromethyl (CF 3 ) were formed under heavy radiation exposure in oxygen. In addition, the expansion of crystallite size or crystal lattice was first reported for the irradiated PTFE. The formation of new chemical groups and the expansion of crystallite size were elucidated by structural changes occurring in irradiation. - Highlights: • The structural change of PTFE irradiated in O 2 is different from that in vacuum. • The double bond is not found in PTFE after irradiation in oxygen. • The new groups like COF, COOH and CF 3 are formed in PTFE after irradiation. • The expansion of crystallite size is observed in the irradiated PTFE

  20. Oxygen diffusion through soil covers on sulphidic mine tailings

    International Nuclear Information System (INIS)

    Yanful, E.K.

    1993-01-01

    Engineered soil covers are being evaluated under Canada's Mine Environment Neutral Drainage (MEND) program for their effectiveness in preventing and controlling acid generation in sulfidic mill tailings. A critical parameter for predicting the performance of these covers is the diffusion coefficient of gaseous oxygen in the cover materials. Laboratory experiments conducted to determine the effective diffusion coefficient of a candidate cover material, a glacial till from an active mine site, are described. The diffusion coefficient is determined by fitting a semianalytic solution of the one-dimensional, transient diffusion equation to experimental gaseous oxygen concentration versus time graphs. Effective diffusion coefficients determined at high water saturations (85%--95%) were of the order of 8 x 10 -8 m 2 /s. The diffusion coefficients decreased with increase in water saturation as a result of the low diffusivity of gaseous oxygen in water relative to that in air and the low solubility of oxygen in water. Placement of soil covers in high saturation conditions would ensure that the flux of oxygen into tailings underneath such covers is low, resulting in low acid flux. This is confirmed by combined laboratory, field, and modeling studies

  1. Oxygen concentration inside a functioning photosynthetic cell.

    Science.gov (United States)

    Kihara, Shigeharu; Hartzler, Daniel A; Savikhin, Sergei

    2014-05-06

    The excess oxygen concentration in the photosynthetic membranes of functioning oxygenic photosynthetic cells was estimated using classical diffusion theory combined with experimental data on oxygen production rates of cyanobacterial cells. The excess oxygen concentration within the plesiomorphic cyanobacterium Gloeobactor violaceus is only 0.025 μM, or four orders of magnitude lower than the oxygen concentration in air-saturated water. Such a low concentration suggests that the first oxygenic photosynthetic bacteria in solitary form could have evolved ∼2.8 billion years ago without special mechanisms to protect them against reactive oxygen species. These mechanisms instead could have been developed during the following ∼500 million years while the oxygen level in the Earth's atmosphere was slowly rising. Excess oxygen concentrations within individual cells of the apomorphic cyanobacteria Synechocystis and Synechococcus are 0.064 and 0.25 μM, respectively. These numbers suggest that intramembrane and intracellular proteins in isolated oxygenic photosynthetic cells are not subjected to excessively high oxygen levels. The situation is different for closely packed colonies of photosynthetic cells. Calculations show that the excess concentration within colonies that are ∼40 μm or larger in diameter can be comparable to the oxygen concentration in air-saturated water, suggesting that species forming colonies require protection against reactive oxygen species even in the absence of oxygen in the surrounding atmosphere. Copyright © 2014 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  2. Muscle tissue saturation in humans studied with two non-invasive optical techniques: a comparative study

    Science.gov (United States)

    Shaharin, Alfi; Krite Svanberg, Emilie; Ellerström, Ida; Subash, Arman Ahamed; Khoptyar, Dmitry; Andersson-Engels, Stefan; Åkeson, Jonas

    2013-11-01

    Muscle tissue saturation (StO2) has been measured with two non-invasive optical techniques and the results were compared. One of the techniques is widely used in the hospitals - the CW-NIRS technique. The other is the photon timeof- flight spectrometer (pTOFS) developed in the Group of Biophotonics, Lund University, Sweden. The wavelengths used in both the techniques are 730 nm and 810 nm. A campaign was arranged to perform measurements on 21 (17 were taken for comparison) healthy adult volunteers (8 women and 13 men). Oxygen saturations were measured at the right lower arm of each volunteer. To observe the effects of different provocations on the oxygen saturation a blood pressure cuff was attached in the upper right arm. For CW-NIRS, the tissue saturation values were in the range from 70-90%, while for pTOFS the values were in the range from 55-60%.

  3. An applicable approach for extracting human heart rate and oxygen saturation during physical movements using a multi-wavelength illumination optoelectronic sensor system

    Science.gov (United States)

    Alharbi, Samah; Hu, Sijung; Mulvaney, David; Blanos, Panagiotis

    2018-02-01

    The ability to gather physiological parameters such as heart rate (HR) and oxygen saturation (SpO2%) during physical movement allows to continuously monitor personal health status without disrupt their normal daily activities. Photoplethysmography (PPG) based pulse oximetry and similar principle devices are unable to extract the HR and SpO2% reliably during physical movement due to interference in the signals that arise from motion artefacts (MAs). In this research, a flexible reflectance multi-wavelength optoelectronic patch sensor (OEPS) has been developed to overcome the susceptibility of conventional pulse oximetry readings to MAs. The OEPS incorporates light embittered diodes as illumination sources with four different wavelengths, e.g. green, orange, red, and infrared unlike the conventional pulse oximetry devices that normally measure the skin absorption of only two wavelengths (red and infrared). The additional green and orange wavelengths were found to be distinguish to the absorption of deoxyhemoglobin (RHb) and oxyhemoglobin (HbO2). The reliability of extracting physiological parameters from the green and orange wavelengths is due to absorbed near to the surface of the skin, thereby shortening the optical path and so effectively reducing the influence of physical movements. To compensate of MAs, a three-axis accelerometer was used as a reference with help of adaptive filter to reduce MAs. The experiments were performed using 15 healthy subjects aged 20 to 30. The primary results show that there are no significant difference of heart rate and oxygen saturation measurements between commercial devices and OEPS Green (r=0.992), Orange(r=0.984), Red(r=0.952) and IR(r=0.97) and SpO2% (r = 0.982, p = 0.894).

  4. Changes in oxygen partial pressure of brain tissue in an animal model of obstructive apnea

    Directory of Open Access Journals (Sweden)

    Torres Marta

    2010-01-01

    Full Text Available Abstract Background Cognitive impairment is one of the main consequences of obstructive sleep apnea (OSA and is usually attributed in part to the oxidative stress caused by intermittent hypoxia in cerebral tissues. The presence of oxygen-reactive species in the brain tissue should be produced by the deoxygenation-reoxygenation cycles which occur at tissue level during recurrent apneic events. However, how changes in arterial blood oxygen saturation (SpO2 during repetitive apneas translate into oxygen partial pressure (PtO2 in brain tissue has not been studied. The objective of this study was to assess whether brain tissue is partially protected from intermittently occurring interruption of O2 supply during recurrent swings in arterial SpO2 in an animal model of OSA. Methods Twenty-four male Sprague-Dawley rats (300-350 g were used. Sixteen rats were anesthetized and non-invasively subjected to recurrent obstructive apneas: 60 apneas/h, 15 s each, for 1 h. A control group of 8 rats was instrumented but not subjected to obstructive apneas. PtO2 in the cerebral cortex was measured using a fast-response oxygen microelectrode. SpO2 was measured by pulse oximetry. The time dependence of arterial SpO2 and brain tissue PtO2 was carried out by Friedman repeated measures ANOVA. Results Arterial SpO2 showed a stable periodic pattern (no significant changes in maximum [95.5 ± 0.5%; m ± SE] and minimum values [83.9 ± 1.3%]. By contrast, brain tissue PtO2 exhibited a different pattern from that of arterial SpO2. The minimum cerebral cortex PtO2 computed during the first apnea (29.6 ± 2.4 mmHg was significantly lower than baseline PtO2 (39.7 ± 2.9 mmHg; p = 0.011. In contrast to SpO2, the minimum and maximum values of PtO2 gradually increased (p 2 were significantly greater relative to baseline and the first apnea dip, respectively. Conclusions These data suggest that the cerebral cortex is partially protected from intermittently occurring interruption of

  5. Phenobarbital and neonatal seizures affect cerebral oxygen metabolism: a near-infrared spectroscopy study.

    Science.gov (United States)

    Sokoloff, Max D; Plegue, Melissa A; Chervin, Ronald D; Barks, John D E; Shellhaas, Renée A

    2015-07-01

    Near-infrared spectroscopy (NIRS) measures oxygen metabolism and is increasingly used for monitoring critically ill neonates. The implications of NIRS-recorded data in this population are poorly understood. We evaluated NIRS monitoring for neonates with seizures. In neonates monitored with video-electroencephalography, NIRS-measured cerebral regional oxygen saturation (rSO2) and systemic O2 saturation were recorded every 5 s. Mean rSO2 was extracted for 1-h blocks before, during, and after phenobarbital doses. For each electrographic seizure, mean rSO2 was extracted for a period of three times the duration of the seizure before and after the ictal pattern, as well as during the seizure. Linear mixed models were developed to assess the impact of phenobarbital administration and of seizures on rSO2 and fractional tissue oxygen extraction. For 20 neonates (estimated gestational age: 39.6 ± 1.5 wk), 61 phenobarbital doses and 40 seizures were analyzed. Cerebral rSO2 rose (P = 0.005), and fractional tissue oxygen extraction declined (P = 0.018) with increasing phenobarbital doses. rSO2 declined during seizures, compared with baseline and postictal phases (baseline 81.2 vs. ictal 77.7 vs. postictal 79.4; P = 0.004). Fractional tissue oxygen extraction was highest during seizures (P = 0.002). Cerebral oxygen metabolism decreases after phenobarbital administration and increases during seizures. These small, but clear, changes in cerebral oxygen metabolism merit assessment for potential clinical impact.

  6. Effect of oxygen fugacity on OH dissolution in olivine under peridotite-saturated conditions: An experimental study at 1.5-7 GPa and 1100-1300 °C

    Science.gov (United States)

    Yang, Xiaozhi

    2016-01-01

    The dissolution of OH in olivine by experimental studies at simulated conditions has attracted increasing interest over the past three decades, and the influence of pressure, temperature and composition has been relatively well constrained. Oxygen fugacity is highly heterogeneous in the upper mantle, on both temporal and spatial scales, and is an important parameter in characterizing many chemical and physical processes in the mantle. However, less attention has been devoted to the effect of oxygen fugacity on OH dissolution in olivine, and the only few available reports on this topic have led to significant inconsistency and debate. In this study, the correlation between oxygen fugacity and OH solubility in Fe-bearing olivine has been systematically investigated by conducting experiments at 1.5-7 GPa and 1100-1300 °C and under peridotite- and fluid-saturated conditions, with natural gem-quality olivine single crystals and fresh peridotite xenoliths as starting materials and with oxygen fugacity controlled by the Fe-FeO, Ni-NiO and Fe2O3-Fe3O4 oxygen buffer pairs. The water concentrations were determined by polarized analyses using a Fourier-transform infrared spectroscopy. The results show that, at all the experimental conditions, the OH bands at both high frequency (∼3650-3450 cm-1) and low frequency (∼3450-3100 cm-1) are prominent. The intensity of OH bands at ∼3355 and 3325 cm-1 increases positively with oxygen fugacity, suggesting a dominant role of Fe3+ in their incorporation. Under otherwise identical conditions, the water content is gradually enhanced with increasing pressure, temperature or oxygen fugacity. The effect of oxygen fugacity on the enhancement of OH solubility appears not sensitive to temperature (1100-1300 °C) at a given pressure, but becomes progressively stronger with increasing pressure from 1.5 to 7 GPa given the temperature. Relative to oxygen fugacity buffers, the OH solubility is on average increased by ∼50% between Fe-FeO and

  7. Cerebral and Renal Oxygen Saturation Are Not Compromised in the Presence of Retrograde Blood Flow in either the Ascending or Descending Aorta in Term or Near-Term Infants with Left-Sided Obstructive Lesions

    NARCIS (Netherlands)

    van der Laan, Michelle E.; Mebius, Mirthe J.; Roofthooft, Marcus T. R.; Bos, Arend F.; Berger, Rolf M. F.; Kooi, Elisabeth M. W.

    2017-01-01

    Background: In infants with left-sided obstructive lesions (LSOL), the presence of retrograde blood flow in either the ascending or descending aorta may lead to diminished cerebral and renal blood flow, respectively. Objectives: Our aim was to compare cerebral and renal tissue oxygen saturation

  8. Will open ocean oxygen stress intensify under climate change?

    Science.gov (United States)

    Gnanadesikan, A.; Dunne, J. P.; John, J.

    2011-07-01

    Global warming is expected to reduce oxygen solubility and vertical exchange in the ocean, changes which would be expected to result in an increase in the volume of hypoxic waters. A simulation made with a full earth system model with dynamical atmosphere, ocean, sea ice and biogeochemical cycling shows that this holds true if the condition for hypoxia is set relatively high. However, the volume of the most hypoxic waters does not increase under global warming, as these waters actually become more oxygenated. We show that the rise in oxygen is associated with a drop in ventilation time. A term-by-term analysis within the least oxygenated waters shows an increased supply of oxygen due to lateral diffusion. compensating an increase in remineralization within these highly hypoxic waters. This lateral diffusive flux is the result of an increase of ventilation along the Chilean coast, as a drying of the region under global warming opens up a region of wintertime convection in our model.

  9. Spontaneous calcium waves in Bergman glia increase with age and hypoxia and may reduce tissue oxygen

    OpenAIRE

    Mathiesen, Claus; Brazhe, Alexey; Thomsen, Kirsten; Lauritzen, Martin

    2012-01-01

    Glial calcium (Ca2+) waves constitute a means to spread signals between glial cells and to neighboring neurons and blood vessels. These waves occur spontaneously in Bergmann glia (BG) of the mouse cerebellar cortex in vivo. Here, we tested three hypotheses: (1) aging and reduced blood oxygen saturation alters wave activity; (2) glial Ca2+ waves change cerebral oxygen metabolism; and (3) neuronal and glial wave activity is correlated. We used two-photon microscopy in the cerebellar cortexes of...

  10. Low oxygen level increases proliferation and metabolic changes in bovine granulosa cells.

    Science.gov (United States)

    Shiratsuki, Shogo; Hara, Tomotaka; Munakata, Yasuhisa; Shirasuna, Koumei; Kuwayama, Takehito; Iwata, Hisataka

    2016-12-05

    The present study addresses molecular backgrounds underlying low oxygen induced metabolic changes and 1.2-fold change in bovine granulosa cell (GCs) proliferation. RNA-seq revealed that low oxygen (5%) upregulated genes associated with HIF-1 and glycolysis and downregulated genes associated with mitochondrial respiration than that in high oxygen level (21%). Low oxygen level induced high glycolytic activity and low mitochondrial function and biogenesis. Low oxygen level enhanced GC proliferation with high expression levels of HIF-1, VEGF, AKT, mTOR, and S6RP, whereas addition of anti-VEGF antibody decreased cellular proliferation with low phosphorylated AKT and mTOR expression levels. Low oxygen level reduced SIRT1, whereas activation of SIRT1 by resveratrol increased mitochondrial replication and decreased cellular proliferation with reduction of phosphorylated mTOR. These results suggest that low oxygen level stimulates the HIF1-VEGF-AKT-mTOR pathway and up-regulates glycolysis, which contributes to GC proliferation, and downregulation of SIRT1 contributes to hypoxia-associated reduction of mitochondria and cellular proliferation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Changes induced in spice paprika powder by treatment with ionizing radiation and saturated steam

    International Nuclear Information System (INIS)

    Kispeter, J.; Bajusz-Kabok, K.; Fekete, M.; Szabo, G.; Fodor, E.; Pali, T.

    2003-01-01

    The changes in spice paprika powder induced by ionizing radiation, saturated steam (SS) and their combination were studied as a function of the absorbed radiation dose and the storage time. The SS treatment lead to a decrease in color content (lightening) after 12 weeks of storage, together with the persistence of free radicals and viscosity changes for a longer period. The results suggest that ionizing radiation is a more advantageous method as concerns preservation of the quality of spice paprika

  12. The influence of norepinephrine and phenylephrine on cerebral perfusion and oxygenation during propofol-remifentanil and propofol-remifentanil-dexmedetomidine anaesthesia in piglets

    DEFF Research Database (Denmark)

    Mikkelsen, Mai Louise Grandsgaard; Ambrus, Rikard; Rasmussen, Rune

    2018-01-01

    of dexmedetomidine. Cerebral perfusion measured by laser speckle contrast imaging was related to cerebral oxygenation as measured by an intracerebral Licox probe (partial pressure of oxygen) and transcranial near infrared spectroscopy technology (NIRS) (cerebral oxygen saturation). Results During propofol......–remifentanil anaesthesia, increases in blood pressure by norepinephrine and phenylephrine did not change cerebral perfusion significantly, but cerebral partial pressure of oxygen (Licox) increased following vasopressors in both groups and increases following norepinephrine were significant (NBP: P = 0.04, LBP: P = 0......–remifentanil–dexmedetomidine anaesthesia was not followed by significant changes in cerebral perfusion. Licox measures increased significantly following both vasopressors in both groups, whereas the decreases in NIRS measures were only significant in the NBP group. Conclusions Cerebral partial pressure of oxygen measured by Licox...

  13. Quadruple labelled dual oxygen and pH-sensitive ratiometric nanosensors

    Directory of Open Access Journals (Sweden)

    Veeren M. Chauhan

    2016-05-01

    Full Text Available Nanosensors capable of simultaneously measuring dissolved oxygen concentrations from 0 to 100% saturation and pH over the full physiological range, from pH 3.5 to 7.5, that advance the methods towards understanding of key biological gradients, were synthesised. A library of water soluble oxygen-sensitive porphyrins, with three substituted charged functional groups and a chemically flexible carboxylate functional group were spectroscopically analysed to assess their sensitivity to changes in dissolved oxygen concentrations as free species in solution and in suspension as nanoparticle conjugates. A platinum cationic porphyrin was taken forward to fabricate ratiometric oxygen-sensitive nanosensors, using 5-(and-6-carboxytetramethylrhodamine (TAMRA as internal standard. In addition, quadruple labelled dual oxygen and pH-sensitive nanosensors were synthesised using the cationic Pt porphyrin, pH-sensitive fluorescein dyes, carboxyfluorescein (FAM and Oregon Green (OG, in a 1:1 ratio, and TAMRA. We envisage the dual oxygen and pH nanosensors will find broad utility in the characterisation of diverse microenvironments, where there are complex interactions between molecular oxygen and pH. Keywords: Fluorescent, Phosphorescent, Nanosensor, Oxygen, pH, Ratiometric, Platinum metalloporphyrin

  14. Children’s Oxygen Administration Strategies Trial (COAST:  A randomised controlled trial of high flow versus oxygen versus control in African children with severe pneumonia [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Kathryn Maitland

    2018-01-01

    Full Text Available Background: In Africa, the clinical syndrome of pneumonia remains the leading cause of morbidity and mortality in children in the post-neonatal period. This represents a significant burden on in-patient services. The targeted use of oxygen and simple, non-invasive methods of respiratory support may be a highly cost-effective means of improving outcome, but the optimal oxygen saturation threshold that results in benefit and the best strategy for delivery are yet to be tested in adequately powered randomised controlled trials. There is, however, an accumulating literature about the harms of oxygen therapy across a range of acute and emergency situations that have stimulated a number of trials investigating permissive hypoxia. Methods: In 4200 African children, aged 2 months to 12 years, presenting to 5 hospitals in East Africa with respiratory distress and hypoxia (oxygen saturation or = 80% (permissive hypoxia; and High flow using AIrVO2TM compared with low flow delivery (routine care. Discussion: The overarching objective is to address the key research gaps in the therapeutic use of oxygen in resource-limited setting in order to provide a better evidence base for future management guidelines. The trial has been designed to address the poor outcomes of children in sub-Saharan Africa, which are associated with high rates of in-hospital mortality, 9-10% (for those with oxygen saturations of 80-92% and 26-30% case fatality for those with oxygen saturations <80%. Clinical trial registration: ISRCTN15622505 Trial status: Recruiting

  15. A new through-tubing oil-saturation measurement system

    International Nuclear Information System (INIS)

    Roscoe, B.A.; Adolph, R.A.; Bontemy, Y.; Cheeseborough, J.C. III; Hall, J.S.; McKeon, D.C.; Pittman, D.; Seeman, B.; Thomas, S.R. Jr.

    1991-01-01

    This paper reports on carbon-oxygen logging which is used primarily to estimate oil saturation in cased-hole conditions when the formation water is fresh or unknown. The drawbacks of current techniques are: slow logging speed, large tool diameter, and excessive sensitivity to borehole fluid composition. A new, slim, neutron-induced gamma ray spectroscopy logging system has been developed to overcome some of these limitations. The new logging service is called the Reservoir Saturation (RST) Tool. Initial field tests are being carried out in the Middle East. The RST tool uses multiple detectors to separate the signal contributions from the borehole and the formation. Therefore, even when the borehole fluid composition is unknown, oil saturation can be determined in addition to the borehole oil fraction. This presents the possibility of logging flowing wells, which ensures that reinvasion and crossflow will not affect the results, and eliminates the costs of well preparation

  16. Non-invasive evaluation of blood oxygen saturation and hematocrit from T1 and T2 relaxation times: In-vitro validation in fetal blood.

    Science.gov (United States)

    Portnoy, Sharon; Seed, Mike; Sled, John G; Macgowan, Christopher K

    2017-12-01

    We propose an analytical method for calculating blood hematocrit (Hct) and oxygen saturation (sO 2 ) from measurements of its T 1 and T 2 relaxation times. Through algebraic substitution, established two-compartment relationships describing R1=T1-1 and R2=T2-1 as a function of hematocrit and oxygen saturation were rearranged to solve for Hct and sO 2 in terms of R 1 and R 2 . Resulting solutions for Hct and sO 2 are the roots of cubic polynomials. Feasibility of the method was established by comparison of Hct and sO 2 estimates obtained from relaxometry measurements (at 1.5 Tesla) in cord blood specimens to ground-truth values obtained by blood gas analysis. Monte Carlo simulations were also conducted to assess the effect of T 1 , T 2 measurement uncertainty on precision of Hct and sO 2 estimates. Good agreement was observed between estimated and ground-truth blood properties (bias = 0.01; 95% limits of agreement = ±0.13 for Hct and sO 2 ). Considering the combined effects of biological variability and random measurement noise, we estimate a typical uncertainty of ±0.1 for Hct, sO 2 estimates. Results demonstrate accurate quantification of Hct and sO 2 from T 1 and T 2 . This method is applicable to noninvasive fetal vessel oximetry-an application where existing oximetry devices are unusable or require risky blood-sampling procedures. Magn Reson Med 78:2352-2359, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  17. Multimillennium changes in dissolved oxygen under global warming: results from an AOGCM and offline ocean biogeochemical model

    Science.gov (United States)

    Yamamoto, A.; Abe-Ouchi, A.; Shigemitsu, M.; Oka, A.; Takahashi, K.; Ohgaito, R.; Yamanaka, Y.

    2016-12-01

    Long-term oceanic oxygen change due to global warming is still unclear; most future projections (such as CMIP5) are only performed until 2100. Indeed, few previous studies using conceptual models project oxygen change in the next thousands of years, showing persistent global oxygen reduction by about 30% in the next 2000 years, even after atmospheric carbon dioxide stops rising. Yet, these models cannot sufficiently represent the ocean circulation change: the key driver of oxygen change. Moreover, considering serious effect oxygen reduction has on marine life and biogeochemical cycling, long-term oxygen change should be projected for higher validity. Therefore, we used a coupled atmosphere-ocean general circulation model (AOGCM) and an offline ocean biogeochemical model, investigating realistic long-term changes in oceanic oxygen concentration and ocean circulation. We integrated these models for 2000 years under atmospheric CO2 doubling and quadrupling. After global oxygen reduction in the first 500 years, oxygen concentration in deep ocean globally recovers and overshoots, despite surface oxygen decrease and weaker Atlantic Meridional Overturning Circulation. Deep ocean convection in the Weddell Sea recovers and overshoots, after initial cessation. Thus, enhanced deep convection and associated Antarctic Bottom Water supply oxygen-rich surface waters to deep ocean, resulting global deep ocean oxygenation. We conclude that the change in ocean circulation in the Southern Ocean potentially drives millennial-scale oxygenation in the deep ocean; contrary to past reported long-term oxygen reduction and general expectation. In presentation, we will discuss the mechanism of response of deep ocean convection in the Weddell Sea and show the volume changes of hypoxic waters.

  18. 2,3-diphosphoglycerate and oxygen supply of tissues in cardiosurgical diabetics.

    Science.gov (United States)

    Beder, I; Mataseje, A; Kittova, M; Carsky, J; Fischer, V

    2005-01-01

    The oxygen supply of tissues was studied under haemodilution in cardiosurgical diabetic and non-diabetic patients. There were 30 cardiosurgery patients examined, 9 were patients with diabetes mellitus.and 21 were non-diabetic patients. Venous blood samples were examined preoperatively, intraoperatively and for 10 days after operation. Haemodilution caused a decrease in haematocrit values in both groups, as well as in the erythrocyte count and haemoglobin concentration. Postoperatively, an increase was recorded in haematological values in both groups, the values had not reached the baseline even by 10th day. Increased values of blood oxygen saturation and partial oxygen pressure during the operation returned to baseline in both groups in the postoperative days. Values of p50 did not change in both groups for the period of observation. The obtained data suggest that sufficient oxygen supply to tissues was ensured under haemodilution in cardiosurgery patients in both groups. These results confirm multifactorial dependence of blood oxygen transport to tissues (Tab. 1, Fig. 3, Ref. 13).

  19. Photoacoustic microscopy of cerebral hemodynamic and oxygen-metabolic responses to anesthetics

    Science.gov (United States)

    Cao, Rui; Li, Jun; Ning, Bo; Sun, Naidi; Wang, Tianxiong; Zuo, Zhiyi; Hu, Song

    2017-02-01

    General anesthetics are known to have profound effects on cerebral hemodynamics and neuronal activities. However, it remains a challenge to directly assess anesthetics-induced hemodynamic and oxygen-metabolic changes from the true baseline under wakefulness at the microscopic level, due to the lack of an enabling technology for high-resolution functional imaging of the awake mouse brain. To address this challenge, we have developed head-restrained photoacoustic microscopy (PAM), which enables simultaneous imaging of the cerebrovascular anatomy, total concentration and oxygen saturation of hemoglobin (CHb and sO2), and blood flow in awake mice. From these hemodynamic measurements, two important metabolic parameters, oxygen extraction fraction (OEF) and the cerebral metabolic rate of oxygen (CMRO2), can be derived. Side-by-side comparison of the mouse brain under wakefulness and anesthesia revealed multifaceted cerebral responses to isoflurane, a volatile anesthetic widely used in preclinical research and clinical practice. Key observations include elevated cerebral blood flow (CBF) and reduced oxygen extraction and metabolism.

  20. New hybrid reflectance optical pulse oximetry sensor for lower oxygen saturation measurement and for broader clinical application

    Science.gov (United States)

    Nogawa, Masamichi; Ching, Chong Thong; Ida, Takeyuki; Itakura, Keiko; Takatani, Setsuo

    1997-06-01

    A new reflectance pulse oximeter sensor for lower arterial oxygen saturation (Sa)2) measurement has been designed and evaluated in animals prior to clinical trials. The new sensor incorporates ten light emitting diode chips for each wavelength of 730 and 880 nm mounted symmetrically and at the radial separation distance of 7 mm around a photodiode chip. The separation distance of 7 mm was chosen to maximize the ratio of the pulsatile to the average plethysmographic signal level at each wavelength. The 730 and 880 wavelength combination was determined to obtain a linear relationship between the reflectance ratio of the 730 and 880 nm wavelengths and Sa)2. In addition to these features of the sensor, the Fast Fourier Transform method was employed to compute the pulsatile and average signal level at each wavelength. The performance of the new reflectance pulse oximeter sensor was evaluated in dogs in comparison to the 665/910 nm sensor. As predicted by the theoretical simulation based on a 3D photon diffusion theory, the 730/880 nm sensor demonstrated an excellent linearity over the SaO2 range from 100 to 30 percent. For the SaO2 range between 100 and 70 percent, the 665/910 and 730/880 sensors showed the standard error of around 3.5 percent and 2.1 percent, respectively, in comparison to the blood samples. For the range between 70 and 30 percent, the standard error of the 730/880 nm sensor was only 2.7 percent, while that of the 665/910 nm sensor was 9.5 percent. The 730/880 sensor showed improved accuracy for a wide range of SaO2 particularly over the range between 70 and 30 percent. This new reflectance sensor can provide noninvasive measurement of SaO2 accurately over the wide saturation range from 100 to 30 percent.

  1. Near-Infrared Spectroscopic Measurement of the Effect of Leg Dominance on Muscle Oxygen Saturation During Cycling

    Science.gov (United States)

    Ellerby, Gwenn E. C.; Lee, Stuart M. C.; Paunescu, Lelia Adelina; Pereira, Chelsea; Smith, Charles P.; Soller, Babs R.

    2011-01-01

    The effect of leg dominance on the symmetry of the biomechanics during cycling remains uncertain -- asymmetries have been observed in kinematics and kinetics, while symmetries were found in muscle activation. No studies have yet investigated the symmetry of muscle metabolism during cycling. Near-infrared spectroscopy (NIRS) provides a non-invasive method to investigate the metabolic responses of specific muscles during cycling. PURPOSE: To determine whether there was an effect of leg dominance on thigh muscle oxygen saturation (SmO2) during incrementally loaded submaximal cycling using NIRS. METHODS: Eight right leg dominant, untrained subjects (5 men, 3 women; 31+/-2 yrs; 168.6+/-1.0 cm; 67.2+/-1.8 kg, mean +/- SE) volunteered to participate. Spectra were collected bilaterally from the vastus lateralis (VL) during supine rest and cycling. SmO2 was calculated using previously published methods. Subjects pedaled at 65 rpm while resistance to pedaling was increased in 0.5 kp increments from 0.5 kp every 3 min until the subject reached 80% of age-predicted maximal heart rate. SmO2 was averaged over 3 min for each completed stage. A two-way ANOVA was performed to test for leg differences. A priori contrasts were used to compare work levels to rest. RESULTS: VL SmO2 was not different between the dominant and non-dominant legs at rest and during exercise (p=0.57). How SmO2 changed with workload was also not different between legs (p=0.32). SmO2 at 0.5 kp (60.3+/-4.0, p=0.12) and 1.0 kp (59.5+/-4.0, p=0.10) was not different from rest (69.1+/-4.0). SmO2 at 1.5 kp (55.4 4.0, p=0.02), 2.0 kp (55.7+/-5.0, p=0.04), and 2.5 kp (43.4+/-7.9, p=0.01) was significantly lower than rest. CONCLUSION: VL SmO2 during cycling is not different between dominant and non-dominant legs and decreases with moderate workload in untrained cyclists. Assuming blood flow is directed equally to both legs, similar levels of oxygen extraction (as indicated by SmO2) suggests the metabolic load of

  2. A high-resolution non-invasive approach to quantify oxygen transport across the capillary fringe and within the underlying groundwater.

    Science.gov (United States)

    Haberer, Christina M; Rolle, Massimo; Liu, Sanheng; Cirpka, Olaf A; Grathwohl, Peter

    2011-03-25

    Oxygen transport across the capillary fringe is relevant for many biogeochemical processes. We present a non-invasive technique, based on optode technology, to measure high-resolution concentration profiles of oxygen across the unsaturated/saturated interface. By conducting a series of quasi two-dimensional flow-through laboratory experiments, we show that vertical hydrodynamic dispersion in the water-saturated part of the capillary fringe is the process limiting the mass transfer of oxygen. A number of experimental conditions were tested in order to investigate the influence of grain size and horizontal flow velocity on transverse vertical dispersion in the capillary fringe. In the same setup, analogous experiments were simultaneously carried out in the fully water-saturated zone, therefore allowing a direct comparison with oxygen transfer across the capillary fringe. The outcomes of the experiments under various conditions show that oxygen transport in the two zones of interest (i.e., the unsaturated/saturated interface and the saturated zone) is characterized by very similar transverse dispersion coefficients. An influence of the capillary fringe morphology on oxygen transport has not been observed. These results may be explained by the narrow grain size distribution used in the experiments, leading to a steep decline in water saturation at the unsaturated/saturated interface and to the absence of trapped gas in this transition zone. We also modeled flow (applying the van Genuchten and the Brooks-Corey relationships) and two-dimensional transport across the capillary fringe, obtaining simulated profiles of equivalent aqueous oxygen concentration that were in good agreement with the observations. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Intramyocardial oxygen transport by quantitative diffuse reflectance spectroscopy in calves

    Science.gov (United States)

    Lindbergh, Tobias; Larsson, Marcus; Szabó, Zoltán; Casimir-Ahn, Henrik; Strömberg, Tomas

    2010-03-01

    Intramyocardial oxygen transport was assessed during open-chest surgery in calves by diffuse reflectance spectroscopy using a small intramuscular fiber-optic probe. The sum of hemo- and myoglobin tissue fraction and oxygen saturation, the tissue fraction and oxidation of cytochrome aa3, and the tissue fraction of methemoglobin were estimated using a calibrated empirical light transport model. Increasing the oxygen content in the inhaled gas, 21%-50%-100%, in five calves (group A) gave an increasing oxygen saturation of 19+/-4%, 24+/-5%, and 28+/-8% (panimals increased with LVAD pump speed (p<0.001, ANOVA) and with oxygen content in inhaled gas (p<0.001, ANOVA). The cytochrome aa3 oxidation level was above 96% in both group A and group B calves, including the two cases involving cardiac arrest. In conclusion, the estimated tissue fractions and oxygenation/oxidation levels of the myocardial chromophores during respiratory and hemodynamic provocations were in agreement with previously presented results, demonstrating the potential of the method.

  4. Accelerated Oxygen Atom Transfer and C-H Bond Oxygenation by Remote Redox Changes in Fe3 Mn-Iodosobenzene Adducts.

    Science.gov (United States)

    de Ruiter, Graham; Carsch, Kurtis M; Gul, Sheraz; Chatterjee, Ruchira; Thompson, Niklas B; Takase, Michael K; Yano, Junko; Agapie, Theodor

    2017-04-18

    We report the synthesis, characterization, and reactivity of [LFe 3 (PhPz) 3 OMn( s PhIO)][OTf] x (3: x=2; 4: x=3), where 4 is one of very few examples of iodosobenzene-metal adducts characterized by X-ray crystallography. Access to these rare heterometallic clusters enabled differentiation of the metal centers involved in oxygen atom transfer (Mn) or redox modulation (Fe). Specifically, 57 Fe Mössbauer and X-ray absorption spectroscopy provided unique insights into how changes in oxidation state (Fe III 2 Fe II Mn II vs. Fe III 3 Mn II ) influence oxygen atom transfer in tetranuclear Fe 3 Mn clusters. In particular, a one-electron redox change at a distal metal site leads to a change in oxygen atom transfer reactivity by ca. two orders of magnitude. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. MR Imaging-derived Oxygen-Hemoglobin Dissociation Curves and Fetal-Placental Oxygen-Hemoglobin Affinities.

    Science.gov (United States)

    Avni, Reut; Golani, Ofra; Akselrod-Ballin, Ayelet; Cohen, Yonni; Biton, Inbal; Garbow, Joel R; Neeman, Michal

    2016-07-01

    Purpose To generate magnetic resonance (MR) imaging-derived, oxygen-hemoglobin dissociation curves and to map fetal-placental oxygen-hemoglobin affinity in pregnant mice noninvasively by combining blood oxygen level-dependent (BOLD) T2* and oxygen-weighted T1 contrast mechanisms under different respiration challenges. Materials and Methods All procedures were approved by the Weizmann Institutional Animal Care and Use Committee. Pregnant mice were analyzed with MR imaging at 9.4 T on embryonic days 14.5 (eight dams and 58 fetuses; imprinting control region ICR strain) and 17.5 (21 dams and 158 fetuses) under respiration challenges ranging from hyperoxia to hypoxia (10 levels of oxygenation, 100%-10%; total imaging time, 100 minutes). A shorter protocol with normoxia to hyperoxia was also performed (five levels of oxygenation, 20%-100%; total imaging time, 60 minutes). Fast spin-echo anatomic images were obtained, followed by sequential acquisition of three-dimensional gradient-echo T2*- and T1-weighted images. Automated registration was applied to align regions of interest of the entire placenta, fetal liver, and maternal liver. Results were compared by using a two-tailed unpaired Student t test. R1 and R2* values were derived for each tissue. MR imaging-based oxygen-hemoglobin dissociation curves were constructed by nonlinear least square fitting of 1 minus the change in R2*divided by R2*at baseline as a function of R1 to a sigmoid-shaped curve. The apparent P50 (oxygen tension at which hemoglobin is 50% saturated) value was derived from the curves, calculated as the R1 scaled value (x) at which the change in R2* divided by R2*at baseline scaled (y) equals 0.5. Results The apparent P50 values were significantly lower in fetal liver than in maternal liver for both gestation stages (day 14.5: 21% ± 5 [P = .04] and day 17.5: 41% ± 7 [P hemoglobin dissociation curves with a shorter protocol that excluded the hypoxic periods was demonstrated. Conclusion MR imaging

  6. Dependence of nitrite oxidation on nitrite and oxygen in low-oxygen seawater

    Science.gov (United States)

    Sun, Xin; Ji, Qixing; Jayakumar, Amal; Ward, Bess B.

    2017-08-01

    Nitrite oxidation is an essential step in transformations of fixed nitrogen. The physiology of nitrite oxidizing bacteria (NOB) implies that the rates of nitrite oxidation should be controlled by concentration of their substrate, nitrite, and the terminal electron acceptor, oxygen. The sensitivities of nitrite oxidation to oxygen and nitrite concentrations were investigated using 15N tracer incubations in the Eastern Tropical North Pacific. Nitrite stimulated nitrite oxidation under low in situ nitrite conditions, following Michaelis-Menten kinetics, indicating that nitrite was the limiting substrate. The nitrite half-saturation constant (Ks = 0.254 ± 0.161 μM) was 1-3 orders of magnitude lower than in cultivated NOB, indicating higher affinity of marine NOB for nitrite. The highest rates of nitrite oxidation were measured in the oxygen depleted zone (ODZ), and were partially inhibited by additions of oxygen. This oxygen sensitivity suggests that ODZ specialist NOB, adapted to low-oxygen conditions, are responsible for apparently anaerobic nitrite oxidation.

  7. Lipid order, saturation and surface property relationships: a study of human meibum saturation.

    Science.gov (United States)

    Mudgil, Poonam; Borchman, Douglas; Yappert, Marta C; Duran, Diana; Cox, Gregory W; Smith, Ryan J; Bhola, Rahul; Dennis, Gary R; Whitehall, John S

    2013-11-01

    Tear film stability decreases with age however the cause(s) of the instability are speculative. Perhaps the more saturated meibum from infants may contribute to tear film stability. The meibum lipid phase transition temperature and lipid hydrocarbon chain order at physiological temperature (33 °C) decrease with increasing age. It is reasonable that stronger lipid-lipid interactions could stabilize the tear film since these interactions must be broken for tear break up to occur. In this study, meibum from a pool of adult donors was saturated catalytically. The influence of saturation on meibum hydrocarbon chain order was determined by infrared spectroscopy. Meibum is in an anhydrous state in the meibomian glands and on the surface of the eyelid. The influence of saturation on the surface properties of meibum was determined using Langmuir trough technology. Saturation of native human meibum did not change the minimum or maximum values of hydrocarbon chain order so at temperatures far above or below the phase transition of human meibum, saturation does not play a role in ordering or disordering the lipid hydrocarbon chains. Saturation did increase the phase transition temperature in human meibum by over 20 °C, a relatively high amount. Surface pressure-area studies showing the late take off and higher maximum surface pressure of saturated meibum compared to native meibum suggest that the saturated meibum film is quite molecularly ordered (stiff molecular arrangement) and elastic (molecules are able to rearrange during compression and expansion) compared with native meibum films which are more fluid agreeing with the infrared spectroscopic results of this study. In saturated meibum, the formation of compacted ordered islands of lipids above the surfactant layer would be expected to decrease the rate of evaporation compared to fluid and more loosely packed native meibum. Higher surface pressure observed with films of saturated meibum compared to native meibum

  8. Effect of oxygen partial pressure on the density of antiphase boundaries in Fe3O4 thin films on Si(100)

    Science.gov (United States)

    Singh, Suraj Kumar; Husain, Sajid; Kumar, Ankit; Chaudhary, Sujeet

    2018-02-01

    Polycrystalline Fe3O4 thin films were grown on Si(100) substrate by reactive DC sputtering at different oxygen partial pressures PO2 for controlling the growth associated density of antiphase boundaries (APBs). The micro-Raman analyses were performed to study the structural and electronic properties in these films. The growth linked changes in the APBs density are probed by electron-phonon coupling strength (λ) and isothermal magnetization measurements. The estimated values of λ are found to vary from 0.39 to 0.56 with the increase in PO2 from 2.2 × 10-5 to 3.0 × 10-5 Torr, respectively. The saturation magnetization (saturation field) values are found to increase (decrease) from 394 (5.9) to 439 (3.0) emu/cm3 (kOe) with the increase in PO2 . The sharp Verwey transition (∼120 K), low saturation field, high saturation magnetization and low value of λ (comparable to the bulk value ∼0.51) clearly affirm the negligible amount of APBs in the high oxygen partial pressure deposited thin films.

  9. Hemodynamic, ventilator, and ECG changes in pediatric patients undergoing extraction

    Directory of Open Access Journals (Sweden)

    Y K Sanadhya

    2013-01-01

    Full Text Available Background: Dental treatment induces pain anxiety and fear. This study was conducted to assess the changes in hemodynamic, ventilator, and electrocardiograph changes during extraction procedure among 12-15-year-old children and compare these changes with anxiety, fear, and pain. Materials and Methods: A purposive sample of 60 patients selected based on inclusion and exclusion criteria underwent study procedure in the dental OPD of a medical college and hospital. The anxiety, fear, and pain were recorded by dental anxiety scale, dental fear scale, and visual analogue scale, respectively, before the start of the procedure. The systolic blood pressure, diastolic blood pressure, heart rate, oxygen saturation, and electrocardiogram changes were monitored during the extraction procedure. The recording was taken four times (preinjection phase, injection, extraction, and postextraction and was analyzed. Results: At the preinjection phase the mean vales were systolic blood pressure (128 ± 11.2, diastolic blood pressure (85.7 ± 6.3, heart rate (79.7 ± 9.3, and oxygen saturation (97.9 ± 5.8. These values increased in injection phases and decreased in extraction phase and the least values were found after 10 min of procedure and this relation was significant for all parameters except oxygen saturation (P = 0.48, NS. ECG abnormalities were seen among 22 patients and were significant before and after injection of Local anesthetic (P = 0.0001, S. Conclusions: Anxiety, fear, and pain have an effect on hemodynamic, ventilator, and cardiovascular parameters during the extraction procedure and hence behavioral management has to be emphasized among children in dental clinics.

  10. Oxygen status during haemodialysis. The Cord-Group

    DEFF Research Database (Denmark)

    Nielsen, A L; Jensen, H Æ; Hegbrant, J

    1995-01-01

    Hypoxia during haemodialysis, mainly acetate, has been reported several times. In our study we have monitored oxygen status during 258 bicarbonate haemodialyses. A significant drop below 80 mmHg in mean oxygen tension occurred. Mean oxygen saturation reflected this drop but did not reach levels...... below 90%. The mean oxygen concentration was on the whole critical low, though slightly increasing during each haemodialysis session due to ultrafiltration. It is concluded that both hypoxia and hypoxaemia do occur during bicarbonate haemodialysis. To a group of patients generally having limited cardiac...... reserves, a poor oxygen status is a potentially serious complication to haemodialysis. Monitoring oxygen status is thus advisable....

  11. Estimation of changes in saturation and pressure from 4D seismic AVO and time-shift analysis

    NARCIS (Netherlands)

    Trani, M.; Arts, R.; Leeuwenburgh, O.; Brouwer, J.

    2011-01-01

    A reliable estimate of reservoir pressure and fluid saturation changes from time-lapse seismic data is difficult to obtain. Existing methods generally suffer from leakage between the estimated parameters. We propose a new method using different combinations of time-lapse seismic attributes based on

  12. Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO₂ sensor.

    Science.gov (United States)

    Shafique, M; Kyriacou, P A; Pal, S K

    2012-06-01

    Photoplethysmography (PPG) is a technique widely used to monitor volumetric blood changes induced by cardiac pulsations. Pulse oximetry uses the technique of PPG to estimate arterial oxygen saturation values (SpO₂). In poorly perfused tissues, SpO₂ readings may be compromised due to the poor quality of the PPG signals. A multimode finger PPG probe that operates simultaneously in reflectance, transmittance and a combined mode called "transreflectance" was developed, in an effort to improve the quality of the PPG signals in states of hypoperfusion. Experiments on 20 volunteers were conducted to evaluate the performance of the multimode PPG sensor and compare the results with a commercial transmittance pulse oximeter. A brachial blood pressure cuff was used to induce artificial hypoperfusion. Results showed that the amplitude of the transreflectance AC PPG signals were significantly different (p signals obtained from the other two conventional PPG sensors (reflectance and transmittance). At induced brachial pressures between 90 and 135 mmHg, the reflectance finger pulse oximeter failed 25 times (failure rate 42.2 %) to estimate SpO₂ values, whereas the transmittance pulse oximeter failed 8 times (failure rate 15.5 %). The transreflectance pulse oximeter failed only 3 times (failure rate 6.8 %) and the commercial pulse oximeter failed 17 times (failure rate 29.4 %).

  13. Capillary-oxygenation-level-dependent near-infrared spectrometry in frontal lobe of humans

    NARCIS (Netherlands)

    Rasmussen, Peter; Dawson, Ellen A.; Nybo, Lars; van Lieshout, Johannes J.; Secher, Niels H.; Gjedde, Albert

    2007-01-01

    Brain function requires oxygen and maintenance of brain capillary oxygenation is important. We evaluated how faithfully frontal lobe near-infrared spectroscopy (NIRS) follows haemoglobin saturation (SCap) and how calculated mitochondrial oxygen tension (PMitoO2) influences motor performance. Twelve

  14. Central venous oxygenation: when physiology explains apparent discrepancies.

    Science.gov (United States)

    Squara, Pierre

    2014-11-10

    Central venous oxygen saturation (ScvO2) >70% or mixed venous oxygen saturation (SvO2) >65% is recommended for both septic and non-septic patients. Although it is the task of experts to suggest clear and simple guidelines, there is a risk of reducing critical care to these simple recommendations. This article reviews the basic physiological and pathological features as well as the metrological issues that provide clear evidence that SvO2 and ScvO2 are adaptative variables with large inter-patient variability. This variability is exemplified in a modeled population of 1,000 standard ICU patients and in a real population of 100 patients including 15,860 measurements. In these populations, it can be seen how optimizing one to three of the four S(c)vO2 components homogenized the patients and yields a clear dependency with the fourth one. This explains the discordant results observed in large studies where cardiac output was increased up to predetermined S(c)vO2 thresholds following arterial oxygen hemoglobin saturation, total body oxygen consumption needs and hemoglobin optimization. Although a systematic S(c)vO2 goal-oriented protocol can be statistically profitable before ICU admission, appropriate intensive care mandates determination of the best compromise between S(c)vO2 and its four components, taking into account the specific constraints of each individual patient.

  15. Development of theoretical oxygen saturation calibration curve based on optical density ratio and optical simulation approach

    Science.gov (United States)

    Jumadi, Nur Anida; Beng, Gan Kok; Ali, Mohd Alauddin Mohd; Zahedi, Edmond; Morsin, Marlia

    2017-09-01

    The implementation of surface-based Monte Carlo simulation technique for oxygen saturation (SaO2) calibration curve estimation is demonstrated in this paper. Generally, the calibration curve is estimated either from the empirical study using animals as the subject of experiment or is derived from mathematical equations. However, the determination of calibration curve using animal is time consuming and requires expertise to conduct the experiment. Alternatively, an optical simulation technique has been used widely in the biomedical optics field due to its capability to exhibit the real tissue behavior. The mathematical relationship between optical density (OD) and optical density ratios (ODR) associated with SaO2 during systole and diastole is used as the basis of obtaining the theoretical calibration curve. The optical properties correspond to systolic and diastolic behaviors were applied to the tissue model to mimic the optical properties of the tissues. Based on the absorbed ray flux at detectors, the OD and ODR were successfully calculated. The simulation results of optical density ratio occurred at every 20 % interval of SaO2 is presented with maximum error of 2.17 % when comparing it with previous numerical simulation technique (MC model). The findings reveal the potential of the proposed method to be used for extended calibration curve study using other wavelength pair.

  16. Analysis of a microscale 'Saturation Phase-change Internal Carnot Engine'

    Energy Technology Data Exchange (ETDEWEB)

    Lurie, Eli [School of Mechanical Engineering, Tel Aviv University, Tel Aviv 69978 (Israel); Kribus, Abraham, E-mail: kribus@eng.tau.ac.i [School of Mechanical Engineering, Tel Aviv University, Tel Aviv 69978 (Israel)

    2010-06-15

    A micro heat engine, based on a cavity filled with a stationary working fluid under liquid-vapor saturation conditions and encapsulated by two membranes, is described and analyzed. This engine design is easy to produce using MEMS technologies and is operated with external heating and cooling. The motion of the membranes is controlled such that the internal pressure and temperature are constant during the heat addition and removal processes, and thus the fluid executes a true internal Carnot cycle. A model of this Saturation Phase-change Internal Carnot Engine (SPICE) was developed including thermodynamic, mechanical and heat transfer aspects. The efficiency and maximum power of the engine are derived. The maximum power point is fixed in a three-parameter space, and operation at this point leads to maximum power density that scales with the inverse square of the engine dimension. Inclusion of the finite heat capacity of the engine wall leads to a strong dependence of performance on engine frequency, and the existence of an optimal frequency. Effects of transient reverse heat flow, and 'parasitic heat' that does not participate in the thermodynamic cycle are observed.

  17. Late Quaternary changes in surface productivity and oxygen ...

    Indian Academy of Sciences (India)

    Changes in the abundance of selected planktic foraminiferal species and some sedimentological parameters at ODP site 728A were examined to understand the fluctuations in the surface productivity and deep sea oxygenation in the NW Arabian Sea during last ∼540 kyr. The increased relative abundances of high fertility ...

  18. 3-D Numerical Investigation on Oxygen Transfer in a Horizontal Venturi Flow with Two Holes

    Directory of Open Access Journals (Sweden)

    Zegao Yin

    2018-02-01

    Full Text Available In order to investigate the dissolved oxygen increase caused by air suction in a horizontal Venturi flow with two holes, a 3-D computational fluid dynamics model was used to explore the water and bubble mixture flow, coupled with a dissolved oxygen transfer model. A series of experiments were conducted to validate the mathematical model. A relative saturation coefficient correlation was examined factoring in dissolved oxygen concentration at the inlet, water velocity at the inlet, the hole’s diameter, contraction ratio at throat section, and the downstream length of Venturi pipe. It was found that the relative saturation coefficient increases with increasing dissolved oxygen concentration at the inlet and downstream length of Venturi pipe respectively. However, it increases with decreasing water velocity at the inlet and contraction ratio at the throat section to some extent. The hole’s diameter plays a complex role in the relative saturation coefficient. The dimensional analysis method and the least square method were used to deduce a simple formula for the relative saturation coefficient, and this was consistent with related data.

  19. The kinetics of oxygen and SO2 consumption by red wines. What do they tell about oxidation mechanisms and about changes in wine composition?

    Science.gov (United States)

    Carrascón, Vanesa; Vallverdú-Queralt, Anna; Meudec, Emmanuelle; Sommerer, Nicolas; Fernandez-Zurbano, Purificación; Ferreira, Vicente

    2018-02-15

    This work seeks to understand the kinetics of O 2 and SO 2 consumption of air-saturated red wine as a function of its chemical composition, and to describe the chemical changes suffered during the process in relation to the kinetics. Oxygen Consumption Rates (OCRs) are faster with higher copper and epigallocatechin contents and with higher absorbance at 620nm and slower with higher levels of gallic acid and catechin terminal units in tannins. Acetaldehyde Reactive Polyphenols (ARPs) may be key elements determining OCRs. It is confirmed that SO 2 is poorly consumed in the first saturation. Phenylalanine, methionine and maybe, cysteine, seem to be consumed instead. A low SO 2 consumption is favoured by low levels of SO 2 , by a low availability of free SO 2 caused by a high anthocyanin/tannin ratio, and by a polyphenolic profile poor in epigallocatechin and rich in catechin-rich tannins. Wines consuming SO 2 efficiently consume more epigallocatechin, prodelphinidins and procyanidins. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Lactate, endothelin, and central venous oxygen saturation as predictors of mortality in patients with Tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Poonam Malhotra Kapoor

    2016-01-01

    Full Text Available Background: Lactate and central venous oxygen saturation (ScVO2 are well known biomarkers for adequacy of tissue oxygenation. Endothelin, an inflammatory marker has been associated with patient′s nutritional status and degree of cyanosis. The aim of this study was to explore the hypothesis that lactate, ScVO2 and endothelin before induction may be predictive of mortality in pediatric cardiac surgery. Methods: We conducted a prospective observational study of 150 pediatric (6 months to 12 years patients who were posted for intracardiac repair for tetralogy of fallot and measured lactate, ScVO2 and endothelin before induction (T1, 20 minutes after protamine administration (T2 and 24 hours after admission to ICU (T3. Results: Preinduction lactate and endothelin levels were found to predict mortality in patients of tetralogy of fallot with an odds ratio of 6.020 (95% CI 2.111-17.168 and 1.292(95% CI 1.091-1.531 respectively. In the ROC curve analysis for lactate at T1, the AUC was 0.713 (95% CI 0.526-0.899 P = 0.019. At the cutoff value of 1.750mmol/lt, the sensitivity and specificity for the prediction of mortality was 63.6% and 65.5%, respectively. For endothelin at T1, the AUC was 0.699 (95% CI 0.516-0.883, P = 0.028 and the cutoff value was ≤2.50 (sensitivity, 63.6%; specificity, 58.3 %. ScVO2 (odds ratio 0.85 at all three time intervals, suggested that improving ScVO2 can lead to 15% reduction in mortality. Conclusions: Lactate, ScVO2 and endothelin all showed association with mortality with lactate having the maximum prediction. Lactate was found to be an independent, reliable and cost-effective measure of prediction of mortality in patients with tetralogy of fallot.

  1. 31P nuclear magnetic resonance spectroscopy studies of tumor energy metabolism and its relationship to intracapillary oxyhemoglobin saturation status and tumor hypoxia.

    Science.gov (United States)

    Rofstad, E K; DeMuth, P; Fenton, B M; Sutherland, R M

    1988-10-01

    Relationships between tumor bioenergetic status on the one hand and intracapillary oxyhemoglobin (HbO2) saturation status and fraction of radiobiologically hypoxic cells on the other were studied using two murine sarcoma lines (KHT, RIF-1) and two human ovarian carcinoma xenograft lines (MLS, OWI). Tumor energy metabolism was studied in vivo by 31P nuclear magnetic resonance (NMR) spectroscopy and the resonance area ratio (PCr + NTP beta)/Pi was used as parameter for bioenergetic status. Intracapillary HbO2 saturation status reflects the oxygen supply conditions in tumors and was measured in vitro using a cryospectrophotometric method. The KHT, RIF-1, and MLS lines showed decreasing bioenergetic status, i.e., decreasing PCr and NTP beta resonances and an increasing Pi resonance, with increasing tumor volume, whereas the OWI line showed no changes in these resonances during tumor growth. The volume-dependence of the HbO2 saturation status differed similarly among the tumor lines; HbO2 saturation status decreased with increasing tumor volume for the KHT, RIF-1, and MLS lines and was independent of tumor volume for the OWI line. Moreover, linear correlations were found between bioenergetic status and HbO2 saturation status for individual tumors of the KHT, RIF-1, and MLS lines. These observations together indicated a direct relationship between 31P-NMR spectral parameters and tumor oxygen supply conditions. However, this relationship was not identical for the different tumor lines, suggesting that it was influenced by intrinsic properties of the tumor cells such as rate of respiration and ability to survive under hypoxia. Similarly, there was no correlation between bioenergetic status and fraction of radiobiologically hypoxic cells across the four tumor lines. This indicates that 31P-NMR spectroscopy data have to be supplemented with other data, e.g., rate of oxygen consumption, cell survival time under hypoxic stress, and/or fraction of metabolically active

  2. Optimizing oxygenation and intubation conditions during awake fibre-optic intubation using a high-flow nasal oxygen-delivery system.

    Science.gov (United States)

    Badiger, S; John, M; Fearnley, R A; Ahmad, I

    2015-10-01

    Awake fibre-optic intubation is a widely practised technique for anticipated difficult airway management. Despite the administration of supplemental oxygen during the procedure, patients are still at risk of hypoxia because of the effects of sedation, local anaesthesia, procedural complications, and the presence of co-morbidities. Traditionally used oxygen-delivery devices are low flow, and most do not have a sufficient reservoir or allow adequate fresh gas flow to meet the patient's peak inspiratory flow rate, nor provide an adequate fractional inspired oxygen concentration to prevent desaturation should complications arise. A prospective observational study was conducted using a high-flow humidified transnasal oxygen-delivery system during awake fibre-optic intubation in 50 patients with anticipated difficult airways. There were no episodes of desaturation or hypercapnia using the high-flow system, and in all patients the oxygen saturation improved above baseline values, despite one instance of apnoea resulting from over-sedation. All patients reported a comfortable experience using the device. The high-flow nasal oxygen-delivery system improves oxygenation saturation, decreases the risk of desaturation during the procedure, and potentially, optimizes conditions for awake fibre-optic intubation. The soft nasal cannulae uniquely allow continuous oxygenation and simultaneous passage of the fibrescope and tracheal tube. The safety of the procedure may be increased, because any obstruction, hypoventilation, or periods of apnoea that may arise may be tolerated for longer, allowing more time to achieve ventilation in an optimally oxygenated patient. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Single-cell measurement of red blood cell oxygen affinity.

    Science.gov (United States)

    Di Caprio, Giuseppe; Stokes, Chris; Higgins, John M; Schonbrun, Ethan

    2015-08-11

    Oxygen is transported throughout the body by hemoglobin (Hb) in red blood cells (RBCs). Although the oxygen affinity of blood is well-understood and routinely assessed in patients by pulse oximetry, variability at the single-cell level has not been previously measured. In contrast, single-cell measurements of RBC volume and Hb concentration are taken millions of times per day by clinical hematology analyzers, and they are important factors in determining the health of the hematologic system. To better understand the variability and determinants of oxygen affinity on a cellular level, we have developed a system that quantifies the oxygen saturation, cell volume, and Hb concentration for individual RBCs in high throughput. We find that the variability in single-cell saturation peaks at an oxygen partial pressure of 2.9%, which corresponds to the maximum slope of the oxygen-Hb dissociation curve. In addition, single-cell oxygen affinity is positively correlated with Hb concentration but independent of osmolarity, which suggests variation in the Hb to 2,3-diphosphoglycerate (2-3 DPG) ratio on a cellular level. By quantifying the functional behavior of a cellular population, our system adds a dimension to blood cell analysis and other measurements of single-cell variability.

  4. A general model to calculate the spin-lattice (T1) relaxation time of blood, accounting for haematocrit, oxygen saturation and magnetic field strength.

    Science.gov (United States)

    Hales, Patrick W; Kirkham, Fenella J; Clark, Christopher A

    2016-02-01

    Many MRI techniques require prior knowledge of the T1-relaxation time of blood (T1bl). An assumed/fixed value is often used; however, T1bl is sensitive to magnetic field (B0), haematocrit (Hct), and oxygen saturation (Y). We aimed to combine data from previous in vitro measurements into a mathematical model, to estimate T1bl as a function of B0, Hct, and Y. The model was shown to predict T1bl from in vivo studies with a good accuracy (± 87 ms). This model allows for improved estimation of T1bl between 1.5-7.0 T while accounting for variations in Hct and Y, leading to improved accuracy of MRI-derived perfusion measurements. © The Author(s) 2015.

  5. Barley seed radiosensitivity following post-hydration in oxygen-, nitrogen- and nitrous oxide-saturated water, 1

    International Nuclear Information System (INIS)

    Singh, S.P.; Kesavan, P.C.

    1990-01-01

    Dry (∼3.5 and 4.0 per cent moisture content) barley seeds were exposed to 350 Gy of 60 Co-γ-rays in vacuo and post-hydrated at 4degC for 8 h in O 2 -, N 2 -, or N 2 O-saturated water. The effect of caffeine and t-butyl alcohol (t-BuOH) dissolved in the post-hydration medium on the magnitude of damage developing under these three different gaseous circumstances was studied. The post-irradiation damage and its modification by caffeine and t-BuOH was assessed in terms of 8-day-old seedling injury, peroxidase activity and total peroxides in the 8-day-old seedlings. Post-irradiation O 2 -saturated hydration caused maximal 8-day-old seedling injury, and increased peroxidase activity with concomitant reduction in total peroxides. Both caffeine and t-BuOH afforded significant radioprotection against post-irradiation O 2 -dependent damage. Post-irradiation N 2 O-saturated hydration was even more significantly radioprotective than the N 2 -saturated post-hydration. Under these circumstances, t-BuOH exerted no effect whatsoever on the N 2 - and N 2 O-mediated post-irradiation damage. Caffeine, on the other hand, significantly potentiated these two components of damage. A brief consideration of the physicochemical events which possibly account for the observed effects is presented. (author)

  6. Extra-cerebral oxygenation influence on near-infrared-spectroscopy-determined frontal lobe oxygenation in healthy volunteers

    DEFF Research Database (Denmark)

    Sørensen, Henrik; Rasmussen, Peter; Siebenmann, Christoph

    2015-01-01

    INTRODUCTION: Frontal lobe oxygenation (Sc O2 ) is assessed by spatially resolved near-infrared spectroscopy (SR-NIRS) although it seems influenced by extra-cerebral oxygenation. We aimed to quantify the impact of extra-cerebral oxygenation on two SR-NIRS derived Sc O2 . METHODS: Multiple...... regression analysis estimated the influence of extra-cerebral oxygenation as exemplified by skin oxygenation (Sskin O2 ) on Sc O2 in 21 healthy subjects exposed to whole-body exercise in hypoxia (Fi O2 = 12%; n = 10) and normoxia (n = 12), whole-body heating, hyperventilation (n = 21), administration...... of norepinephrine with and without petCO2 -correction (n = 15), phenylephrine and head-up tilt (n = 7). Sc O2 was assessed simultaneously by NIRO-200NX (Sniro O2 ) and INVOS-4100 (Sinvos O2 ). Arterial (Sa O2 ) and jugular bulb oxygen saturations (Sj O2 ) were obtained. RESULTS: The regression analysis indicated...

  7. pH-Sensitive Amphiphilic Block-Copolymers for Transport and Controlled Release of Oxygen

    KAUST Repository

    Patil, Yogesh Raghunath

    2017-05-31

    Saturated fluorocarbons, their derivatives and emulsions are capable of dissolving anomalously high amounts of oxygen and other gases. The mechanistic aspects of this remarkable effect remain to be explored experimentally. Here, the synthesis of a library of amphiphilic fluorous block-copolymers incorporating different fluorinated monomers is described, and the capacity of these copolymers for oxygen transport in water is systematically investigated. The structure of the fluorous monomer employed was found to have a profound effect on both the oxygen-carrying capacity and the gas release kinetics of the polymer emulsions. Furthermore, the release of O2 from the polymer dispersions could be triggered by changing the pH of the solution. This is the first example of a polymer-based system for controlled release of a non-polar, non-covalently entrapped respiratory gas.

  8. pH-Sensitive Amphiphilic Block-Copolymers for Transport and Controlled Release of Oxygen

    KAUST Repository

    Patil, Yogesh Raghunath; Almahdali, Sarah; Vu, Khanh B.; Zapsas, Georgios; Hadjichristidis, Nikolaos; Rodionov, Valentin

    2017-01-01

    Saturated fluorocarbons, their derivatives and emulsions are capable of dissolving anomalously high amounts of oxygen and other gases. The mechanistic aspects of this remarkable effect remain to be explored experimentally. Here, the synthesis of a library of amphiphilic fluorous block-copolymers incorporating different fluorinated monomers is described, and the capacity of these copolymers for oxygen transport in water is systematically investigated. The structure of the fluorous monomer employed was found to have a profound effect on both the oxygen-carrying capacity and the gas release kinetics of the polymer emulsions. Furthermore, the release of O2 from the polymer dispersions could be triggered by changing the pH of the solution. This is the first example of a polymer-based system for controlled release of a non-polar, non-covalently entrapped respiratory gas.

  9. Rejection of Erroneous Saturation Data in Optical Pulse Oximetry in Newborn Patients

    Science.gov (United States)

    Scalise, L.; Marchionni, Paolo; Carnielli, Virgilio P.

    2011-08-01

    Pulse oximetry (PO) is extensively used in intensive care unit (ICU); this is mainly due to the fact that it is a non-invasive and real-time monitoring method. PO allows to measure arterial oxygen saturation (SaO2) and in particular hemoglobin oxygenation. Optical PO is typically realized by the use of a clip (to be applied on the ear or on the finger top) containing a couple of monochromatic LED sources and a photodiode. The main drawback with the use of PO is the presence of movement artifacts or disturbance due to optical sources and skin, causing erroneous saturation data. The aim of this work is to present the measurement procedure based on a specially developed algorithm able to reject erroneous oxygen saturation data during long lasting monitoring of patients in ICU and to compare measurement data with reference data provided by EGA. We have collected SaO2 data from a standard PO and used an intensive care unit monitor to collect data. This device was connected to our acquisition system and heart rate (HR) and SaO2 data were acquired and processed by our specially developed algorithm and directly reproduced on the PC screen for use by the clinicians. The algorithm here used for the individuation and rejection of erroneous saturation data is based on the assessment of the difference between the Heart Rate (HR) measured by respectively by the ECG and PO. We have used an emogasanalyzer (EGA) for comparison of the measured data. The study was carried out in a neonatal intensive care unit (NICU), using 817 data coming from 24 patients and the observation time was of about 10000 hours. Results show a reduction in the maximum difference between the SaO2 data measured, simultaneously, on the same patient by the EGA and by the proposed method of 14.20% and of the 4.76% in average over the 817 samples. The measurement method proposed is therefore able to individuate and eliminate the erroneous saturation data due to motion artifacts and reported by the pulse oxymeter

  10. Simulation of consolidation in partially saturated soil materials

    International Nuclear Information System (INIS)

    Narasimhan, T.N.

    1982-03-01

    Partially saturated soil materials undergo consolidation, heave, collapse and failure due to changes in pore fluid pressure. The precise nature of the mechanics of such deformations is only poorly understood at present. Experimental evidence has shown that the volume change behavior of unsaturated soils cannot be adequately explained through changes in effective stress, even when a saturation dependent parameter is incorporated into the definition of effective stress. Two independent stress-state variables, involving combinations of total stress, pore air pressure and pore water pressure, are required to characterize volume changes and saturation changes in the partially saturated state. In general, two coupled conservation equations, one for the water-phase and the other for the air-phase need to be solved in order to predict the deformation behavior of unsaturated soils. If directional displacements and changes in the stress-field are required, then the conservation equations are to be integrated with an additional set of multi-dimensional force balance equations. For lack of a sufficient understanding of elastic constants such as Poisson's Ratio and Lame's constants as applied to unsaturated soils, little has been achieved so far in integrating the conservation equations and the force balance equations. For the long-term modeling of consolidation with respect to uranium mill tailings, it may be acceptable and economical to solve a single conservation equation for water, assuming that the air-phase is continuous and is at atmospheric pressure everywhere in the soil. The greatest challenge to modeling consolidation in the unsaturated zone at the presnt time is to develop enough experimental data defining the variation of void ratio and saturation with reference to the two chosen stress-state variables

  11. [Role of erythrocyte cytoplasmic structures in changes in the affinity of haemoglobin for oxygen].

    Science.gov (United States)

    Bryzgalova, N Iu; Brazhe, N A; Iusipovich, A U; Maksimov, G V; Rubin, A B

    2009-01-01

    Changes in the refractive index of the cytoplasm and the affinity of haemoporphyrin of erythrocyte haemoglobin to oxygen (pH, 2,3-diphosphoglycerate) have been investigated using laser interference microscopy and Raman spectroscopy. It has been established that a decrease in pH and an increase in the content of 2,3-diphosphoglycerate are accompanied by changes in both the form of the cell and the refractive index of the cytoplasm and the affinity of haemoporphyrin of hemoglobin to oxygen. It has been shown that as pH is reduced, the capacity of haemoporphyrin for binding oxygen decreases and as the concentration of 2,3-diphosphoglycerate is increased, the ability of haemoporphyrin for oxygen reabsorption increases.

  12. Oxygen and oxidative stress in the perinatal period

    Directory of Open Access Journals (Sweden)

    Isabel Torres-Cuevas

    2017-08-01

    Full Text Available Fetal life evolves in a hypoxic environment. Changes in the oxygen content in utero caused by conditions such as pre-eclampsia or type I diabetes or by oxygen supplementation to the mother lead to increased free radical production and correlate with perinatal outcomes.In the fetal-to-neonatal transition asphyxia is characterized by intermittent periods of hypoxia ischemia that may evolve to hypoxic ischemic encephalopathy associated with neurocognitive, motor, and neurosensorial impairment. Free radicals generated upon reoxygenation may notably increase brain damage. Hence, clinical trials have shown that the use of 100% oxygen given with positive pressure in the airways of the newborn infant during resuscitation causes more oxidative stress than using air, and increases mortality.Preterm infants are endowed with an immature lung and antioxidant system. Clinical stabilization of preterm infants after birth frequently requires positive pressure ventilation with a gas admixture that contains oxygen to achieve a normal heart rate and arterial oxygen saturation. In randomized controlled trials the use high oxygen concentrations (90% to 100% has caused more oxidative stress and clinical complications that the use of lower oxygen concentrations (30–60%. A correlation between the amount of oxygen received during resuscitation and the level of biomarkers of oxidative stress and clinical outcomes was established. Thus, based on clinical outcomes and analytical results of oxidative stress biomarkers relevant changes were introduced in the resuscitation policies. However, it should be underscored that analysis of oxidative stress biomarkers in biofluids has only been used in experimental and clinical research but not in clinical routine. The complexity of the technical procedures, lack of automation, and cost of these determinations have hindered the routine use of biomarkers in the clinical setting. Overcoming these technical and economical difficulties

  13. The competing impacts of climate change and nutrient reductions on dissolved oxygen in Chesapeake Bay

    Science.gov (United States)

    Irby, Isaac D.; Friedrichs, Marjorie A. M.; Da, Fei; Hinson, Kyle E.

    2018-05-01

    The Chesapeake Bay region is projected to experience changes in temperature, sea level, and precipitation as a result of climate change. This research uses an estuarine-watershed hydrodynamic-biogeochemical modeling system along with projected mid-21st-century changes in temperature, freshwater flow, and sea level rise to explore the impact climate change may have on future Chesapeake Bay dissolved-oxygen (DO) concentrations and the potential success of nutrient reductions in attaining mandated estuarine water quality improvements. Results indicate that warming bay waters will decrease oxygen solubility year-round, while also increasing oxygen utilization via respiration and remineralization, primarily impacting bottom oxygen in the spring. Rising sea level will increase estuarine circulation, reducing residence time in bottom waters and increasing stratification. As a result, oxygen concentrations in bottom waters are projected to increase, while oxygen concentrations at mid-depths (3 < DO < 5 mg L-1) will typically decrease. Changes in precipitation are projected to deliver higher winter and spring freshwater flow and nutrient loads, fueling increased primary production. Together, these multiple climate impacts will lower DO throughout the Chesapeake Bay and negatively impact progress towards meeting water quality standards associated with the Chesapeake Bay Total Maximum Daily Load. However, this research also shows that the potential impacts of climate change will be significantly smaller than improvements in DO expected in response to the required nutrient reductions, especially at the anoxic and hypoxic levels. Overall, increased temperature exhibits the strongest control on the change in future DO concentrations, primarily due to decreased solubility, while sea level rise is expected to exert a small positive impact and increased winter river flow is anticipated to exert a small negative impact.

  14. Abnormal gas sensing characteristics arising from catalyzed morphological changes of ionsorbed oxygen

    International Nuclear Information System (INIS)

    Xue Xinyu; Chen Zhaohui; Ma Chunhua; Xing Lili; Chen Yujin; Wang Yanguo; Wang Taihong

    2010-01-01

    Abnormal gas sensing characteristics are observed at low temperature in uniformly loaded Pt-SnO 2 nanorod gas sensors. The sensors operated at 200 deg. C exhibit opposite variations of resistances, and the change of resistance decreases with increasing ethanol concentration. In contrast, the sensors operated at 300 deg. C show regular behavior and the sensitivity is extremely high. Such behaviors are ascribed to Pt-catalyzed morphological changes of ionsorbed oxygen at low temperature. The present results are the bases for further investigating the effect of ionsorbed oxygen morphologies on gas sensing.

  15. Safety in the use of compressed air versus oxygen for the ophthalmic patient.

    Science.gov (United States)

    Rodgers, Laura A; Kulwicki, Anahid

    2002-02-01

    Oxygen, routinely administered during surgery to avoid hypoxia, poses risks including increased likelihood of surgical room fires and predisposition to retinal phototoxicity in patients. Compressed air to supplement ventilation may be safer than oxygen. The purpose of this study was to determine whether hypoxia occurs more frequently when compressed air replaces supplemental oxygen during ophthalmic surgery. A convenience sample of 111 patients was randomly assigned to receive supplemental oxygen (group 1) or compressed air (group 2). Patients with serious cardiac or pulmonary disease were excluded. Blood oxygen levels were monitored during surgery by pulse oximetry. Oxygen was administered to all group 2 patients whose oxygen saturation fell to less than 90% or by more than 5% below baseline. No differences were observed between groups in age, ASA classification, type of surgery, or anesthetic drugs or doses. Minor, but statistically higher oxygen values were observed in group 1. The frequency with which oxygen saturation decreased below 90% or below 5% of baseline was similar in both groups. Supplemental oxygen is not required routinely in selected patients undergoing ophthalmic surgery. By using compressed air, the risk of operating room fires and retinal phototoxicity may be reduced.

  16. Solubility of C-O-H volatiles in graphite-saturated martian basalts and application to martian atmospheric evolution

    Science.gov (United States)

    Stanley, B. D.; Hirschmann, M. M.; Withers, A. C.

    2012-12-01

    The modern martian atmosphere is thin, leading to surface conditions too cold to support liquid water. Yet, there is evidence of liquid surface water early in martian history that is commonly thought to require a thick CO2 atmosphere. Our previous work follows the analysis developed by Holloway and co-workers (Holloway et al. 1992; Holloway 1998), which predicts a linear relationship between CO2 and oxygen fugacity (fO2) in graphite-saturated silicate melts. At low oxygen fugacity, the solubility of CO2 in silicate melts is therefore very low. Such low calculated solubilities under reducing conditions lead to small fluxes of CO2 associated with martian magmatism, and therefore production of a thick volcanogenic CO2 atmosphere could require a prohibitively large volume of mantle-derived magma. The key assumption in these previous calculations is that the carbonate ion is the chief soluble C-O-H species. The results of the calculations would not be affected appreciably if molecular CO2, rather than carbonate ion, were an important species, but could be entirely different if there were other appreciable C-species such as CO, carbonyl (C=O) complexes, carbide (Si-C), or CH4. Clearly, graphite-saturated experiments are required to explore how much volcanogenic C may be degassed by reduced martian lavas. A series of piston-cylinder experiments were performed on synthetic martian starting materials over a range of oxygen fugacities (IW+2.3 to IW-0.9), and at pressures of 1-3 GPa and temperatures of 1340-1600 °C in Pt-graphite double capsules. CO2 contents in experimental glasses were determined using Fourier transform infrared spectroscopy (FTIR) and range from 0.0026-0.50 wt%. CO2 solubilities change by one order of magnitude with an order of magnitude change in oxygen fugacity, as predicted by previous work. Secondary ion mass spectrometry (SIMS) determinations of C contents in glasses range from 0.0131-0.2626 wt%. C contents determined by SIMS are consistently higher

  17. Minimally invasive prediction of ScvO2 in high-risk surgery : The introduction of a model Index of Oxygenation

    NARCIS (Netherlands)

    de Grooth, Harm-Jan S.; Vos, Jaap Jan; Scheeren, Thomas; van Beest, Paul

    2014-01-01

    INTRODUCTION: The purpose of this study was to examine the trilateral relationship between cardiac index (CI), tissue oxygen saturation (StO2) and central venous oxygen saturation (ScvO2) and subsequently develop a model to predict ScvO2 on minimal invasive manner in patients undergoing major

  18. Quantification of photocatalytic oxygenation of human blood.

    Science.gov (United States)

    Subrahmanyam, Aryasomayajula; Thangaraj, Paul R; Kanuru, Chandrasekhar; Jayakumar, Albert; Gopal, Jayashree

    2014-04-01

    Photocatalytic oxygenation of human blood is an emerging concept based on the principle of photocatalytic splitting of water into oxygen and hydrogen. This communication reports: (i) a design of a photocatalytic cell (PC) that separates the blood from UV (incident) radiation source, (ii) a pH, temperature and flow controlled circuit designed for quantifying the oxygenation of human blood by photocatalysis and (iii) measuring the current efficacy of ITO/TiO2 nano thin films in oxygenating human blood in a dynamic circuit in real time. The average increase in oxygen saturation was around 5% above baseline compared to control (p<0.0005). We believe this is one of the first attempts to quantify photocatalytic oxygenation of human blood under controlled conditions. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. One hour effects of salbutamol and formoterol on blood pressure, heart rate and oxygen saturation in asthmatics

    Directory of Open Access Journals (Sweden)

    Geraldo Andrade Capuchinho-Júnior

    2008-05-01

    Full Text Available Aim: To analyse systolic (SBP and diastolic blood pressure (DBP, partial oxygen saturation (SpO2 and heart rate (HR disorders for an hour after short and long acting ß2-agonists. Material and methods: Twenty-four severe persistent asthma Pulmonology outpatients at Hospital Universitario Gaffree e Guinle were selected. SBP, DBP, SpO2 and HR values were determined before and after 400 μg of salbutamol and 12 μg of formoterol, on different days, with a minimum interval of 24 hours. Results: All patients showed ventilatory obstruction, as seen by a reduced FEV1/FVC ratio. There was no statistical SBP/DBP/HR difference after bronchodilator agents, but SpO2 increased with salbutamol. Conclusion: A standard dose of salbutamol and formoterol does not cause haemodynamic disorder. Resumo: Objectivo: Analisar os possíveis efeitos do uso de β-2-agonistas, de curta e longa duração, nas pressões arteriais sistólica (PAS e diastólica (PAD, na saturação parcial de oxigénio (SpO2 e na frequência cardíaca (FC, durante o período de uma hora. Material e métodos: Vinte e quatro doentes com asma persistente grave, em tratamento no ambulatório de Pneumologia do Hospital Universitário Gaffrée e Guinle, foram seleccionados para um ensaio clínico sequencial e cruzado. Os valores da PAS, PAD, SpO2 e FC foram registados antes e após o uso de broncodilatadores, salbutamol 400 μg e formoterol 12 μg, em dias diferentes, com intervalo mínimo de 24 horas. Resultados: Todos os doentes apresentaram distúrbio ventilatório obstrutivo, identificado pela redução da relação entre o volume expiratório forçado no primeiro segundo (VEMS e a capacidade vital forçada (CVF. Após o uso de substância broncodilatadora, não houve variação significativa nas PAS e PAD, nem na FC; porém, a SpO2 aumentou com o uso de salbutamol. Conclusão: Não foram observadas

  20. Tackling the Saturation of Oxygen: The Use of Phosphorus and Sulfur as Proxies within the Neutral Interstellar Medium of Star-forming Galaxies

    Science.gov (United States)

    James, B.; Aloisi, A.

    2018-02-01

    The abundance of oxygen in galaxies is widely used in furthering our understanding of galaxy formation and evolution. Unfortunately, direct measurements of O/H in the neutral gas are extremely difficult to obtain, as the only O I line available within the Hubble Space Telescope (HST) UV wavelength range (1150–3200 Å) is often saturated. As such, proxies for oxygen are needed to indirectly derive O/H via the assumption that solar ratios based on local Milky Way sight lines hold in different environments. In this paper we assess the validity of using two such proxies, P II and S II, within more typical star-forming environments. Using HST-Cosmic Origins Spectrograph (COS) far-UV (FUV) spectra of a sample of nearby star-forming galaxies (SFGs) and the oxygen abundances in their ionized gas, we demonstrate that both P and S are mildly depleted with respect to O and follow a trend, log(P II/S II) = -1.73 +/- 0.18, in excellent agreement with the solar ratio of {log}{({{P}}/{{S}})}ȯ =-1.71 +/- 0.04 over the large range of metallicities (0.03–3.2 Z ⊙) and H I column densities ({log}[N(H I)/cm‑2] =18.44–21.28) spanned by the sample. From literature data we show evidence that both elements individually trace oxygen according to their respective solar ratios across a wide range of environments. Our findings demonst-rate that the solar ratios of {log}{({{P}}/{{O}})}ȯ =-3.28+/- 0.06 and {log}{({{S}}/{{O}})}ȯ =-1.57+/- 0.06 can both be used to derive reliable O/H abundances in the neutral gas of local and high-redshift SFGs. The difference between O/H in the ionized- and neutral gas phases is studied with respect to metallicity and H I content. The observed trends are consistent with galactic outflows and/or star formation inefficiency affecting the most metal-poor galaxies, with the possibility of primordial gas accretion at all metallicities.

  1. Gill structural change in response to turbidity has no effect on the oxygen uptake of a juvenile sparid fish.

    Science.gov (United States)

    Cumming, H; Herbert, N A

    2016-01-01

    Turbidity as a result of increased suspended sediments in coastal waters is an environmental stress of worldwide concern. Recent research on fish suggests that detrimental changes to gill structure can occur in turbid waters, with speculation that these alterations diminish fitness variables, such as growth and development, by negatively impacting the O 2 uptake capacity (respiration) of fish. Specifically to address this unknown, the impact of turbid water on the gill structure, somatic growth rate and O 2 uptake rates of a juvenile sparid species ( Pagrus auratus ) was addressed following exposure to five different turbidity treatments (turbidity units) for 30 days. Significant gill structural change was apparent with a progressive increase in turbidity and was quantified as a reduction in lamellar density, as well as an increase in basal hyperplasia, epithelial lifting and increased oxygen diffusion distance across the lamellae. The weight of control fish did not change throughout the experiment, but all fish exposed to turbid waters lost weight, and weight loss increased with nephelometric turbidity units, confirming that long-term turbidity exposure is detrimental to growth productivity. The growth of fish could be impacted in a variety of ways, but the specific hypothesis that structural alteration of the gills impairs O 2 uptake across the gills and limits growth fitness was not supported because there was no measurable difference in the standard metabolic rate, maximal metabolic rate, aerobic metabolic scope or critical oxygen saturation limit of fish measured in clear water after 30 days of exposure. Although impaired O 2 uptake as a result of structurally adjusted gills is unlikely to be the cause of poor fish growth, the exact mechanism by which growth productivity is affected in turbid conditions remains unclear and warrants further investigation.

  2. Correlation of results obtained by in-vivo optical spectroscopy with measured blood oxygen saturation using a positive linear regression fit

    Science.gov (United States)

    McCormick, Patrick W.; Lewis, Gary D.; Dujovny, Manuel; Ausman, James I.; Stewart, Mick; Widman, Ronald A.

    1992-05-01

    Near infrared light generated by specialized instrumentation was passed through artificially oxygenated human blood during simultaneous sampling by a co-oximeter. Characteristic absorption spectra were analyzed to calculate the ratio of oxygenated to reduced hemoglobin. A positive linear regression fit between diffuse transmission oximetry and measured blood oxygenation over the range 23% to 99% (r2 equals .98, p signal was observed in the patient over time. The procedure was able to be performed clinically without difficulty; rSO2 values recorded continuously demonstrate the usefulness of the technique. Using the same instrumentation, arterial input and cerebral response functions, generated by IV tracer bolus, were deconvoluted to measure mean cerebral transit time. Date collected over time provided a sensitive index of changes in cerebral blood flow as a result of therapeutic maneuvers.

  3. The competing impacts of climate change and nutrient reductions on dissolved oxygen in Chesapeake Bay

    Directory of Open Access Journals (Sweden)

    I. D. Irby

    2018-05-01

    Full Text Available The Chesapeake Bay region is projected to experience changes in temperature, sea level, and precipitation as a result of climate change. This research uses an estuarine-watershed hydrodynamic–biogeochemical modeling system along with projected mid-21st-century changes in temperature, freshwater flow, and sea level rise to explore the impact climate change may have on future Chesapeake Bay dissolved-oxygen (DO concentrations and the potential success of nutrient reductions in attaining mandated estuarine water quality improvements. Results indicate that warming bay waters will decrease oxygen solubility year-round, while also increasing oxygen utilization via respiration and remineralization, primarily impacting bottom oxygen in the spring. Rising sea level will increase estuarine circulation, reducing residence time in bottom waters and increasing stratification. As a result, oxygen concentrations in bottom waters are projected to increase, while oxygen concentrations at mid-depths (3 < DO < 5 mg L−1 will typically decrease. Changes in precipitation are projected to deliver higher winter and spring freshwater flow and nutrient loads, fueling increased primary production. Together, these multiple climate impacts will lower DO throughout the Chesapeake Bay and negatively impact progress towards meeting water quality standards associated with the Chesapeake Bay Total Maximum Daily Load. However, this research also shows that the potential impacts of climate change will be significantly smaller than improvements in DO expected in response to the required nutrient reductions, especially at the anoxic and hypoxic levels. Overall, increased temperature exhibits the strongest control on the change in future DO concentrations, primarily due to decreased solubility, while sea level rise is expected to exert a small positive impact and increased winter river flow is anticipated to exert a small negative impact.

  4. Oxygen and oxidative stress in the perinatal period.

    Science.gov (United States)

    Torres-Cuevas, Isabel; Parra-Llorca, Anna; Sánchez-Illana, Angel; Nuñez-Ramiro, Antonio; Kuligowski, Julia; Cháfer-Pericás, Consuelo; Cernada, María; Escobar, Justo; Vento, Máximo

    2017-08-01

    Fetal life evolves in a hypoxic environment. Changes in the oxygen content in utero caused by conditions such as pre-eclampsia or type I diabetes or by oxygen supplementation to the mother lead to increased free radical production and correlate with perinatal outcomes. In the fetal-to-neonatal transition asphyxia is characterized by intermittent periods of hypoxia ischemia that may evolve to hypoxic ischemic encephalopathy associated with neurocognitive, motor, and neurosensorial impairment. Free radicals generated upon reoxygenation may notably increase brain damage. Hence, clinical trials have shown that the use of 100% oxygen given with positive pressure in the airways of the newborn infant during resuscitation causes more oxidative stress than using air, and increases mortality. Preterm infants are endowed with an immature lung and antioxidant system. Clinical stabilization of preterm infants after birth frequently requires positive pressure ventilation with a gas admixture that contains oxygen to achieve a normal heart rate and arterial oxygen saturation. In randomized controlled trials the use high oxygen concentrations (90% to 100%) has caused more oxidative stress and clinical complications that the use of lower oxygen concentrations (30-60%). A correlation between the amount of oxygen received during resuscitation and the level of biomarkers of oxidative stress and clinical outcomes was established. Thus, based on clinical outcomes and analytical results of oxidative stress biomarkers relevant changes were introduced in the resuscitation policies. However, it should be underscored that analysis of oxidative stress biomarkers in biofluids has only been used in experimental and clinical research but not in clinical routine. The complexity of the technical procedures, lack of automation, and cost of these determinations have hindered the routine use of biomarkers in the clinical setting. Overcoming these technical and economical difficulties constitutes a

  5. A high-fat, high-saturated fat diet decreases insulin sensitivity without changing intra-abdominal fat in weight-stable overweight and obese adults.

    Science.gov (United States)

    von Frankenberg, Anize D; Marina, Anna; Song, Xiaoling; Callahan, Holly S; Kratz, Mario; Utzschneider, Kristina M

    2017-02-01

    We sought to determine the effects of dietary fat on insulin sensitivity and whether changes in insulin sensitivity were explained by changes in abdominal fat distribution or very low-density lipoprotein (VLDL) fatty acid composition. Overweight/obese adults with normal glucose tolerance consumed a control diet (35 % fat/12 % saturated fat/47 % carbohydrate) for 10 days, followed by a 4-week low-fat diet (LFD, n = 10: 20 % fat/8 % saturated fat/62 % carbohydrate) or high-fat diet (HFD, n = 10: 55 % fat/25 % saturated fat/27 % carbohydrate). All foods and their eucaloric energy content were provided. Insulin sensitivity was measured by labeled hyperinsulinemic-euglycemic clamps, abdominal fat distribution by MRI, and fasting VLDL fatty acids by gas chromatography. The rate of glucose disposal (Rd) during low- and high-dose insulin decreased on the HFD but remained unchanged on the LFD (Rd-low: LFD: 0.12 ± 0.11 vs. HFD: -0.37 ± 0.15 mmol/min, mean ± SE, p vs. HFD: -0.71 ± 0.26 mmol/min, p = 0.08). Hepatic insulin sensitivity did not change. Changes in subcutaneous fat were positively associated with changes in insulin sensitivity on the LFD (r = 0.78, p fat. The LFD led to an increase in VLDL palmitic (16:0), stearic (18:0), and palmitoleic (16:1n7c) acids, while no changes were observed on the HFD. Changes in VLDL n-6 docosapentaenoic acid (22:5n6) were strongly associated with changes in insulin sensitivity on both diets (LFD: r = -0.77; p fat and saturated fat adversely affects insulin sensitivity and thereby might contribute to the development of type 2 diabetes. CLINICALTRIALS. NCT00930371.

  6. Nitrogen saturation in stream ecosystems.

    Science.gov (United States)

    Earl, Stevan R; Valett, H Maurice; Webster, Jackson R

    2006-12-01

    The concept of nitrogen (N) saturation has organized the assessment of N loading in terrestrial ecosystems. Here we extend the concept to lotic ecosystems by coupling Michaelis-Menten kinetics and nutrient spiraling. We propose a series of saturation response types, which may be used to characterize the proximity of streams to N saturation. We conducted a series of short-term N releases using a tracer (15NO3-N) to measure uptake. Experiments were conducted in streams spanning a gradient of background N concentration. Uptake increased in four of six streams as NO3-N was incrementally elevated, indicating that these streams were not saturated. Uptake generally corresponded to Michaelis-Menten kinetics but deviated from the model in two streams where some other growth-critical factor may have been limiting. Proximity to saturation was correlated to background N concentration but was better predicted by the ratio of dissolved inorganic N (DIN) to soluble reactive phosphorus (SRP), suggesting phosphorus limitation in several high-N streams. Uptake velocity, a reflection of uptake efficiency, declined nonlinearly with increasing N amendment in all streams. At the same time, uptake velocity was highest in the low-N streams. Our conceptual model of N transport, uptake, and uptake efficiency suggests that, while streams may be active sites of N uptake on the landscape, N saturation contributes to nonlinear changes in stream N dynamics that correspond to decreased uptake efficiency.

  7. Clinical score and arterial oxygen saturation in children with wheezing associated respiratory illness (WARI).

    Science.gov (United States)

    Sritippayawan, S; Deerojanawong, J; Prapphal, N

    2000-10-01

    To determine the correlation between clinical score (based on respiratory rate, chest wall retractions, air entry, wheezing, consciousness and audible wheezing) and arterial oxygen saturation (SaO2: measured by pulse oximetry) as well as the most appropriate total score for predicting hypoxemia (SaO2 WARI). 70 children (1 month-5 years old) hospitalized in the Department of Pediatrics, Chulalongkorn Hospital with the diagnosis of WARI from January 1, 1996 to December 31, 1996 were studied. Half of them were diagnosed to have acute lower respiratory tract infection (LRI) with wheezing while the remainder had reactive airway disease (RAD). Cross sectional, analytical study. In each group of patients, the clinical score and SaO2 were assessed by the same pediatrician throughout the study. The correlation between the clinical signs and SaO2 as well as the cut off point of total score for predicting hypoxemia were analyzed. The sensitivity, specificity and accuracy of that total score in predicting hypoxemia were also calculated. In both groups of patients (acute LRI with wheezing and RAD group), the clinical signs correlated with SaO2 were wheezing (rs = -0.67 and -0.47 respectively) and chest wall retractions (rs = -0.57 and -0.59 respectively). Total score was also correlated with SaO2 (rs = -0.68 and -0.5 respectively). The cut off point of total score in predicting hypoxemia was 4 providing 80 per cent sensitivity in both groups with accuracy 74.3 per cent and 80 per cent respectively. This clinical score may be used to assess the severity of hypoxemia in WARI patients. Wheezing, chest wall retractions and total score correlated well with SaO2. The total score > 4 was most appropriate in predicting hypoxemia in both children with RAD and wheezing associated with LRI.

  8. Intra-dialytic blood oxygen saturation (SO2): association with dialysis hypotension (the SOGLIA Study).

    Science.gov (United States)

    Mancini, E; Perazzini, C; Gesualdo, L; Aucella, F; Limido, A; Scolari, F; Savoldi, S; Tramonti, M; Corazza, L; Atti, M; Severi, S; Bolasco, P; Santoro, A

    2017-12-01

    Intradialytic hypotension (IDH) has a dramatic impact on the main outcomes of dialysis patients. Early warning of hemodynamic worsening during dialysis would enable preventive measures to be taken. Blood oxygen saturation (SO 2 ) is used for hemodynamic monitoring in the critical care setting and may provide useful information about IDH onset. To evaluate whether short- and medium-term variations in the SO 2 signal (ST-SO 2var , MT-SO 2var ,) during dialysis are a predictor of IDH. In this 3-month observational cohort study, 51 hypotension-prone chronic hemodialysis (HD) patients, with vascular access by arteriovenous fistula (AVF) or central venous catheter (CVC), were enrolled. Continuous non-invasive blood SO 2 was monitored (fc = 0.2 Hz) by an optical sensor on the arterial line of the extracorporeal circulation; blood pressure (every 30 min), symptoms and their time of appearance were noted. Predictive power of IDH was expressed by the area under curve (AUC) sensitivity and specificity based on intradialytic variations in SO 2 . A total of 1290 HD sessions were analyzed. Overall, off-line ST-SO 2var analysis proved able to correctly predict IDH in 67 % of the sessions where IDH occurred. The best predictive performance was found in the presence of highly arterialized AVF (SO 2  > 95 %) (75 % sensitivity; AUC 0.825; p < 0.05). On the contrary, in sessions with CVC, IDH prediction proved more efficient by MT-SO 2var (AUC 0.575; p = 0.01). Intradialytic SO 2 variability could be a valid parameter to detect in advance the hemodynamic worsening that precedes IDH. Appropriate timely intervention could help prevent IDH onset.

  9. Impurities of oxygen in silicon

    International Nuclear Information System (INIS)

    Gomes, V.M.S.

    1985-01-01

    The electronic structure of oxygen complex defects in silicon, using molecular cluster model with saturation by watson sphere into the formalism of Xα multiple scattering method is studied. A systematic study of the simulation of perfect silicon crystal and an analysis of the increasing of atom number in the clusters are done to choose the suitable cluster for the calculations. The divacancy in three charge states (Si:V 2 + , Si:V 2 0 , Si:V 2 - ), of the oxygen pair (Si:O 2 ) and the oxygen-vacancy pair (Si:O.V) neighbours in the silicon lattice, is studied. Distortions for the symmetry were included in the Si:V 2 + and Si:O 2 systems. The behavior of defect levels related to the cluster size of Si:V 2 0 and Si:O 2 systems, the insulated oxygen impurity of silicon in interstitial position (Si:O i ), and the complexes involving four oxygen atoms are analysed. (M.C.K.) [pt

  10. Effect of oxygen clusters on optics, magnetism, and conductivity of (In2O3)0.9(SrO)0.1

    Science.gov (United States)

    Okunev, V. D.; Szymczak, H.; Szymczak, R.; Gierłowski, P.; Glot, A. B.; Bondarchuk, A. N.; Burkhovetski, V. V.

    2016-04-01

    We show that in In2O3-SrO ceramics with disordered structure and oxygen clusters in nanovoids, the band tails of valence and conduction bands form "negative" gap. Two types of magnetism are observed. One of them caused by formation of the "dangling bond+O2- ion" centers has been found in the samples saturated with oxygen. Another type is associated with the presence of dangling bonds in the oxygen-depleted samples. At Tconductivity of the samples. At T<54.8 K, the effects related to magnetic phase transitions in the clusters of crystalline oxygen are observed. The changes in resistance of the samples in the range of T=5-300 K correspond to the Mott's law at a dependence of local activation energy on the phase state of oxygen clusters.

  11. Oxygen titration after resuscitation from out-of-hospital cardiac arrest: a multi-centre, randomised controlled pilot study (the EXACT pilot trial).

    Science.gov (United States)

    Bray, Janet E; Hein, Cindy; Smith, Karen; Stephenson, Michael; Grantham, Hugh; Finn, Judith; Stub, Dion; Cameron, Peter

    2018-04-20

    Recent studies suggest the administration of 100% oxygen to hyperoxic levels following return-of-spontaneous-circulation (ROSC) post-cardiac arrest may be harmful. However, the feasibility and safety of oxygen titration in the prehospital setting is unknown. We conducted a multi-centre, phase-2 study testing whether prehospital titration of oxygen results in an equivalent number of patients arriving at hospital with oxygen saturations SpO2 ≥ 94%. We enrolled unconscious adults with: sustained ROSC; initial shockable rhythm; an advanced airway; and an SpO2 ≥ 95%. Initially (Sept 2015-March 2016) patients were randomised 1:1 to either 2 litres/minute (L/min) oxygen (titrated) or >10 L/min oxygen (control) via a bag-valve reservoir. However, one site experienced a high number of desaturations (SpO2 titrated arm and this arm was changed (April 2016) to an initial reduction of oxygen to 4 L/min then, if tolerated, to 2 L/min, and the desaturation limit was decreased to titrated (n = 37: 2L/min = 20 and 2-4 L/min = 17) oxygen or control (n = 24). Patients allocated to titrated oxygen were more likely to desaturate compared to controls ((SpO2 titrated: 90% vs. control: 100%) and all patients had a SpO2 ≥ 90%. One patient (control) re-arrested. Survival to hospital discharge was similar. Oxygen titration post-ROSC is feasible in the prehospital environment, but incremental titration commencing at 4L/min oxygen flow may be needed to maintain an oxygen saturation >90% (NCT02499042). Copyright © 2018. Published by Elsevier B.V.

  12. Changes in transcutaneous oxygen tension during exercise in pulmonary emphysema.

    OpenAIRE

    Hughes, J A; Gray, B J; Hutchison, D C

    1984-01-01

    Continuous measurements of transcutaneous oxygen tension (tcPO2) were made in 23 patients with radiological evidence of emphysema, at rest and during a maximal progressive exercise test. tcPO2 during the final phase of exercise was compared with tcPO2 at rest; the mean change (exercising minus resting value) in tcPO2 (delta tcPO2) was -0.8 mm Hg (SD 10.5, range -18 to +25) (-0.1 kPa (SD 1.4, range -2.4 to +3.3]. delta tcPO2 was correlated with: resting arterial oxygen tension (PaO2) (r = 0.60...

  13. A new method to measure local oxygen consumption in human skeletal muscle during dynamic exercise using near-infrared spectroscopy

    International Nuclear Information System (INIS)

    Binzoni, Tiziano; Cooper, Chris E; Wittekind, Anna L; Beneke, Ralph; Elwell, Clare E; Leung, Terence S; Van De Ville, Dimitri

    2010-01-01

    Near infrared spectroscopy (NIRS) can readily report on changes in blood volume and oxygenation. However, it has proved more problematic to measure real-time changes in blood flow and oxygen consumption. Here we report the development of a novel method using NIRS to measure local oxygen consumption in human muscle. The method utilizes the blood volume changes induced by the muscle pump during rhythmically contracting exercising skeletal muscle. We found that the saturation of the blood during the contraction phase was lower than that during the relaxation phase. The calculated oxygen drop was then divided by the contraction time to generate a value for the muscle oxygen consumption in the optical region of interest. As a test we measured the muscle oxygen consumption in the human vastus lateralis during exercise on a cycle ergometer by 11 trained male athletes (32 ± 11 years old) at 40% and 110% peak aerobic power. We saw an increase from 13.78 µmol 100 g −1 min −1 to 19.72 µmol 100 g −1 min −1 with the increase in power. The measurements are theoretically exempt from usual NIRS confounders such as myoglobin and adipose tissue and could provide a useful tool for studying human physiology

  14. Photoacoustic Imaging in Oxygen Detection

    Directory of Open Access Journals (Sweden)

    Fei Cao

    2017-12-01

    Full Text Available Oxygen level, including blood oxygen saturation (sO2 and tissue oxygen partial pressure (pO2, are crucial physiological parameters in life science. This paper reviews the importance of these two parameters and the detection methods for them, focusing on the application of photoacoustic imaging in this scenario. sO2 is traditionally detected with optical spectra-based methods, and has recently been proven uniquely efficient by using photoacoustic methods. pO2, on the other hand, is typically detected by PET, MRI, or pure optical approaches, yet with limited spatial resolution, imaging frame rate, or penetration depth. Great potential has also been demonstrated by employing photoacoustic imaging to overcome the existing limitations of the aforementioned techniques.

  15. Long term highly saturated fat diet does not induce NASH in Wistar rats

    Directory of Open Access Journals (Sweden)

    Filippi Céline

    2007-02-01

    Full Text Available Abstract Background Understanding of nonalcoholic steatohepatitis (NASH is hampered by the lack of a suitable model. Our aim was to investigate whether long term high saturated-fat feeding would induce NASH in rats. Methods 21 day-old rats fed high fat diets for 14 weeks, with either coconut oil or butter, and were compared with rats feeding a standard diet or a methionine choline-deficient (MCD diet, a non physiological model of NASH. Results MCDD fed rats rapidly lost weight and showed NASH features. Rats fed coconut (86% of saturated fatty acid or butter (51% of saturated fatty acid had an increased caloric intake (+143% and +30%. At the end of the study period, total lipid ingestion in term of percentage of energy intake was higher in both coconut (45% and butter (42% groups than in the standard (7% diet group. No change in body mass was observed as compared with standard rats at the end of the experiment. However, high fat fed rats were fattier with enlarged white and brown adipose tissue (BAT depots, but they showed no liver steatosis and no difference in triglyceride content in hepatocytes, as compared with standard rats. Absence of hepatic lipid accumulation with high fat diets was not related to a higher lipid oxidation by isolated hepatocytes (unchanged ketogenesis and oxygen consumption or hepatic mitochondrial respiration but was rather associated with a rise in BAT uncoupling protein UCP1 (+25–28% vs standard. Conclusion Long term high saturated fat feeding led to increased "peripheral" fat storage and BAT thermogenesis but did not induce hepatic steatosis and NASH.

  16. Saturation of bentonite dependent upon temperature

    International Nuclear Information System (INIS)

    Hausmannova, Lucie; Vasicek, Radek

    2010-01-01

    Document available in extended abstract form only. The fundamental idea behind the long-term safe operation of a deep repository is the use of the Multi-barrier system principle. Barriers may well differ according to the type of host rock in which the repository is located. It is assumed that the buffer in the granitic host rock environment will consist of swelling clays which boast the ideal properties for such a function i.e. low permeability, high swelling pressure, self-healing ability etc. all of which are affected primarily by mineralogy and dry density. Water content plays a crucial role in the activation of swelling pressure as well as, subsequently, in the potential self healing of the various contact areas of the numerous buffer components made from bentonite. In the case of a deep repository, a change in water content is not only connected with the possible intake of water from the host rock, but also with its redistribution owing to changes in temperature after the insertion of the heat source (disposal waste package containing spent fuel) into the repository 'nest'. The principal reason for the experimental testing of this high dry density material is the uncertainty with regard to its saturation ability (final water content or the degree of saturation) at higher temperatures. The results of the Mock-Up-CZ experiment showed that when the barrier is constantly supplied with a saturation medium over a long time period the water content in the barrier as well as the degree of saturation settle independently of temperature. The Mock-Up-CZ experiment was performed at temperatures of 30 deg. - 90 deg. C in the barrier; therefore it was decided to experimentally verify this behaviour by means of targeted laboratory tests. A temperature of 110 deg. C was added to the set of experimental temperatures resulting in samples being tested at 25 deg. C, 95 deg. C and 110 deg. C. The degree of saturation is defined as the ratio of pore water volume to pore

  17. Low pO2 Contributes to Potential Error in Oxygen Saturation Calculations Using a Point-of-Care Assay.

    Science.gov (United States)

    Gunsolus, Ian L; Love, Sara A; Kohl, Louis P; Schmidt, Martin; Apple, Fred S

    2017-12-20

    The present study addressed the accuracy of calculated oxygen saturation (sO2) using point-of-care (POC) testing compared with measured values on a blood gas analyzer. In total, 3,323 sO2 values were measured in 1,180 patients using a CO-oximeter (ABL 800 Flex; Radiometer, Copenhagen, Denmark). Measured parameters were then used to calculate an expected sO2 for the POC method (Abbott i-STAT; Abbott POC, Princeton, NJ). Cases in which calculated sO2 differed from measured sO2 by 10% or more were analyzed. Of the 3,323 comparisons performed, 260 (8%) showed discrepancies (± ≥10%) between measured and calculated sO2 values. Ninety-four of discrepant measurements (245 of 260) occurred when pO2 was less than 50 mm Hg. pH and bicarbonate distributions shifted to lower values in discrepant vs nondiscrepant cases. Our results suggest that the likelihood of discrepant sO2 is 27% among patients with pO2 less than 50 mm Hg. Direct measurement of sO2 by CO-oximetry is strongly suggested in this clinical scenario. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  18. Real-time changes in brain tissue oxygen during endovascular treatment of cerebral vasospasm

    DEFF Research Database (Denmark)

    Rasmussen, Rune; Bache, Søren; Stavngaard, Trine

    2015-01-01

    pressure (PtiO₂) in target parenchyma. However, during the intervention, dangerously low levels of brain tissue oxygen, leading to cerebral infarction, may occur. Thus, no clinical improvement was seen in two of the patients and a dramatic worsening was observed in the third patient. Because the decrease...... minute-by-minute changes in brain tissue oxygen during balloon angioplasty and intraarterial administration of vasodilators in three patients.Our results confirm that endovascular intervention is capable of not only resolving angiographic vasospasm, but also of normalizing values of brain tissue oxygen...... in brain tissue oxygen was seen after administration of vasopressor agents, this may be a contributing factor....

  19. Carbon dioxide narcosis due to inappropriate oxygen delivery: a case report.

    Science.gov (United States)

    Herren, Thomas; Achermann, Eva; Hegi, Thomas; Reber, Adrian; Stäubli, Max

    2017-07-28

    Oxygen delivery to patients with chronic obstructive pulmonary disease may be challenging because of their potential hypoxic ventilatory drive. However, some oxygen delivery systems such as non-rebreathing face masks with an oxygen reservoir bag require high oxygen flow for adequate oxygenation and to avoid carbon dioxide rebreathing. A 72-year-old Caucasian man with severe chronic obstructive pulmonary disease was admitted to the emergency department because of worsening dyspnea and an oxygen saturation of 81% measured by pulse oximetry. Oxygen was administered using a non-rebreathing mask with an oxygen reservoir bag attached. For fear of removing the hypoxic stimulus to respiration the oxygen flow was inappropriately limited to 4L/minute. The patient developed carbon dioxide narcosis and had to be intubated and mechanically ventilated. Non-rebreathing masks with oxygen reservoir bags must be fed with an oxygen flow exceeding the patient's minute ventilation (>6-10 L/minute.). If not, the amount of oxygen delivered will be too small to effectively increase the arterial oxygen saturation. Moreover, the risk of carbon dioxide rebreathing dramatically increases if the flow of oxygen to a non-rebreathing mask is lower than the minute ventilation, especially in patients with chronic obstructive pulmonary disease and low tidal volumes. Non-rebreathing masks (with oxygen reservoir bags) must be used cautiously by experienced medical staff and with an appropriately high oxygen flow of 10-15 L/minute. Nevertheless, arterial blood gases must be analyzed regularly for early detection of a rise in partial pressure of carbon dioxide in arterial blood in patients with chronic obstructive pulmonary disease and a hypoxic ventilatory drive. These patients are more safely managed using a nasal cannula with an oxygen flow of 1-2L/minute or a simple face mask with an oxygen flow of 5L/minute.

  20. Effects of beach-chair position and induced hypotension on cerebral oxygen saturation in patients undergoing arthroscopic shoulder surgery.

    Science.gov (United States)

    Lee, Jae Hoon; Min, Kyeong Tae; Chun, Yong-Min; Kim, Eun Jung; Choi, Seung Ho

    2011-07-01

    We investigated the effects of the beach-chair position and induced hypotension on regional cerebral oxygen saturation (rSO(2)) in patients undergoing arthroscopic shoulder surgery by using near-infrared spectroscopy. Twenty-eight patients scheduled for arthroscopic shoulder surgery were enrolled prospectively. After induction of anesthesia, mechanical ventilation was controlled to maintain Paco(2) at 35 to 40 mm Hg. Anesthesia was maintained with sevoflurane and remifentanil. After radial artery cannulation, mean arterial pressure (MAP) was measured at the external auditory meatus level and maintained between 60 and 65 mm Hg. The rSO(2) was measured by use of near-infrared spectroscopy. MAP and rSO(2) were recorded at the following times: before induction (T(0)), immediately after induction (T(1) [baseline]), after beach-chair position (T(2)), immediately after induced hypotension (T(3)), 1 hour after induced hypotension (T(4)), and after supine position at the end of surgery (T(5)). Cerebral desaturation was defined as a reduction in rSO(2) to less than 80% of baseline value for 15 seconds or greater. A total of 27 patients were evaluated until the end of this study. The MAP at T(2) was significantly lower than that at T(1). The MAP values at T(3) and T(4) were significantly lower than those at T(1) and T(2). The rSO(2) at T(2) was significantly lower than that at T(1). Unlike the pattern of change in the MAP, there was no additional decrease in rSO(2) at T(3) and T(4). There were 2 patients who had an episode of cerebral desaturation. The beach-chair position combined with induced hypotension significantly decreases rSO(2) in patients undergoing shoulder arthroscopic surgery under general anesthesia. Level IV, study of nonconsecutive patients without consistently applied reference gold standard. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. Assessment of the oxygen consumption in the backfill. Geochemical modelling in a saturated backfill

    International Nuclear Information System (INIS)

    Grandia, Fidel; Domenech, Cristina; Arcos, David; Duro, Lara

    2006-11-01

    The consumption of oxygen in the deep disposal is a major concern due to the ability of this element to corrode the canisters where high level nuclear wastes (HLNW) are disposed. The anoxic conditions initially present in a deep geologic environment are disturbed by the excavation of the repository facilities. After sealing the deposition holes and tunnels using clay-based materials, oxygen remains dissolved in porewater or as a gas phase in the unsaturated pores. The main mechanisms of oxygen depletion that can be considered in the backfill materials are: (1) diffusion into the surrounding rock and (2) kinetic reactions with accessory minerals and organic matter existing in the backfill. In this report, a set of numerical simulations are carried out in one and two dimensions in order to test the effect on the oxygen concentration in the pore water of all these mechanisms. The backfill considered is a 0/70 mixture of MX-80 bentonite and crushed material from the excavation itself. In addition to organic matter, the solid phases with reducing capacity in the backfill are Fe(II)-bearing minerals: pyrite (FeS 2 ) and siderite (FeCO) (as accessory minerals in the bentonite) and Fe-biotite (from the crushed granite). In the simulations, other chemical processes like cation exchange and surface complexation onto clay surfaces, and thermodynamic equilibrium with calcite, gypsum and quartz are considered. Initial composition of porewater is obtained by equilibrating the Forsmark groundwater with the backfill material. The 1D simulation consists of a number of cells with no reactive minerals or organic matter representing granite. The central cell, however, contains oxygen and reactive minerals resembling a backfill. Oxygen is allowed to move only by diffusion. The 2D model simulates the interaction with a backfill of a granitic groundwater flowing through a fracture. Like in the 1D model, the backfill contains oxygen and reactive solids. The results are very similar in

  2. Assessment of the oxygen consumption in the backfill. Geochemical modelling in a saturated backfill

    Energy Technology Data Exchange (ETDEWEB)

    Grandia, Fidel; Domenech, Cristina; Arcos, David; Duro, Lara [Enviros Spain S.L., Barcelona (Spain)

    2006-11-15

    The consumption of oxygen in the deep disposal is a major concern due to the ability of this element to corrode the canisters where high level nuclear wastes (HLNW) are disposed. The anoxic conditions initially present in a deep geologic environment are disturbed by the excavation of the repository facilities. After sealing the deposition holes and tunnels using clay-based materials, oxygen remains dissolved in porewater or as a gas phase in the unsaturated pores. The main mechanisms of oxygen depletion that can be considered in the backfill materials are: (1) diffusion into the surrounding rock and (2) kinetic reactions with accessory minerals and organic matter existing in the backfill. In this report, a set of numerical simulations are carried out in one and two dimensions in order to test the effect on the oxygen concentration in the pore water of all these mechanisms. The backfill considered is a 0/70 mixture of MX-80 bentonite and crushed material from the excavation itself. In addition to organic matter, the solid phases with reducing capacity in the backfill are Fe(II)-bearing minerals: pyrite (FeS{sub 2}) and siderite (FeCO) (as accessory minerals in the bentonite) and Fe-biotite (from the crushed granite). In the simulations, other chemical processes like cation exchange and surface complexation onto clay surfaces, and thermodynamic equilibrium with calcite, gypsum and quartz are considered. Initial composition of porewater is obtained by equilibrating the Forsmark groundwater with the backfill material. The 1D simulation consists of a number of cells with no reactive minerals or organic matter representing granite. The central cell, however, contains oxygen and reactive minerals resembling a backfill. Oxygen is allowed to move only by diffusion. The 2D model simulates the interaction with a backfill of a granitic groundwater flowing through a fracture. Like in the 1D model, the backfill contains oxygen and reactive solids. The results are very similar in

  3. Asthma and hemoglobinopathy: when is supplemental oxygen required?

    Science.gov (United States)

    Joseph, Leon; Brickner-Braun, Inbal; Pinshow, Berry; Goldberg, Shmuel; Miskin, Hagit; Picard, Elie

    2013-10-01

    Asthma is the most common reason for referral to the emergency department in childhood. In severe attacks, supplemental O2 is given when oxygen saturation level is asthma attack. Simultaneously, P(a)O2 was normal. A diagnosis of abnormal hemoglobin with decreased oxygen affinity (hemoglobin Seattle) was made on hemoglobin electrophoresis and genetic analysis. To ascertain when supplemental oxygen was needed, an oxygen dissociation curve was plotted using the tonometer technique, and it was found that an S(p)O2 of 70% is parallel to a P(a)O2 of 60 mmHg. Plotting an oxygen dissociation curve is a simple reproducible method to determine when supplemental oxygen is required for a child with a hemoglobinopathy. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.

  4. The SafeBoosC Phase II Randomised Clinical Trial : A Treatment Guideline for Targeted Near-Infrared-Derived Cerebral Tissue Oxygenation versus Standard Treatment in Extremely Preterm Infants

    NARCIS (Netherlands)

    Pellicer, Adelina; Greisen, Gorm; Benders, Manon; Claris, Olivier; Dempsey, Eugene; Fumagalli, Monica; Gluud, Christian; Hagmann, Cornelia; Hellstroem-Westas, Lena; Hyttel-Sorensen, Simon; Lemmers, Petra; Naulaers, Gunnar; Pichler, Gerhard; Roll, Claudia; van Bel, Frank; van Oeveren, Wim; Skoog, Maria; Wolf, Martin; Austin, Topun

    2013-01-01

    Near-infrared spectroscopy-derived regional tissue oxygen saturation of haemoglobin (rSto(2)) reflects venous oxygen saturation. If cerebral metabolism is stable, rSto(2) can be used as an estimate of cerebral oxygen delivery. The SafeBoosC phase II randomised clinical trial hypothesises that the

  5. A brief clinical case of monitoring of oxygenator performance and patient-machine interdependency during prolonged veno-venous extracorporeal membrane oxygenation.

    Science.gov (United States)

    Belliato, Mirko; Degani, Antonella; Buffa, Antonino; Sciutti, Fabio; Pagani, Michele; Pellegrini, Carlo; Iotti, Giorgio Antonio

    2017-10-01

    Monitoring veno-venous extracorporeal membrane oxygenation (vvECMO) during 76 days of continuous support in a 42-years old patient with end-stage pulmonary disease, listed for double-lung transplantation. Applying a new monitor (Landing ® , Eurosets, Medolla, Italy) and describing how measured and calculated parameters can be used to understand the variable interdependency between artificial membrane lung (ML) and patient native lung (NL). During vvECMO, in order to understand how the respiratory function is shared between ML and NL, ideally we should obtain data about oxygen transfer and CO 2 removal, both by ML and NL. Measurements for NL can be made on the mechanical ventilator. Measurements for ML are typically made from gas analysis on blood samples drawn from the ECMO system before and after the oxygenator, and therefore are non-continuous. Differently, the Landing monitor provides a continuous measurement of the oxygen transfer from the ML, combined with hemoglobin level, saturation of drained blood and saturation of reinfused blood. Moreover, the Landing monitor provides hemodynamics data about circulation through the ECMO system, with blood flow, pre-oxygenator pressure and post-oxygenator pressure. Of note, measurements include the drain negative pressure, whose monitoring may be particularly useful to prevent hemolysis. Real-time monitoring of vvECMO provides data helpful to understand the complex picture of a patient with severely damaged lungs on one side and an artificial lung on the other side. Data from vvECMO monitoring may help to adapt the settings of both mechanical ventilator and vvECMO. Data about oxygen transfer by the oxygenator are important to evaluate the performance of the device and may help to avoid unnecessary replacements, thus reducing risks and costs.

  6. Nasal Cannula Apneic Oxygenation Prevents Desaturation During Endotracheal Intubation: An Integrative Literature Review

    Directory of Open Access Journals (Sweden)

    Bill R. Christian

    2018-02-01

    Full Text Available Patients requiring emergency airway management may be at greater risk of acute hypoxemic events because of underlying lung pathology, high metabolic demands, insufficient respiratory drive, obesity, or the inability to protect their airway against aspiration. Emergency tracheal intubation is often required before complete information needed to assess the risk of procedural hypoxia is acquired (i.e., arterial blood gas level, hemoglobin value, or chest radiograph. During pre-oxygenation, administering high-flow nasal oxygen in addition to a non-rebreather face mask can significantly boost the effective inspired oxygen. Similarly, with the apnea created by rapid sequence intubation (RSI procedures, the same high-flow nasal cannula can help maintain or increase oxygen saturation during efforts to secure the tube (oral intubation. Thus, the use of nasal oxygen during pre-oxygenation and continued during apnea can prevent hypoxia before and during intubation, extending safe apnea time, and improve first-pass success attempts. We conducted a literature review of nasal-cannula apneic oxygenation during intubation, focusing on two components: oxygen saturation during intubation, and oxygen desaturation time. We performed an electronic literature search from 1980 to November 2017, using PubMed, Elsevier, ScienceDirect, and EBSCO. We identified 14 studies that pointed toward the benefits of using nasal cannula during emergency intubation.

  7. Comparison of the OxyMask and Venturi mask in the delivery of supplemental oxygen: Pilot study in oxygen-dependent patients

    Science.gov (United States)

    Beecroft, Jaime M; Hanly, Patrick J

    2006-01-01

    BACKGROUND: The OxyMask (Southmedic Inc, Canada) is a new face mask for oxygen delivery that uses a small ‘diffuser’ to concentrate and direct oxygen toward the mouth and nose. The authors hypothesized that this unique design would enable the OxyMask to deliver oxygen more efficiently than a Venturi mask (Hudson RCI, USA) in patients with chronic hypoxemia. METHODS: Oxygen-dependent patients with chronic, stable respiratory disease were recruited to compare the OxyMask and Venturi mask in a randomized, single-blind, cross-over design. Baseline blood oxygen saturation (SaO2) was established breathing room air, followed in a random order by supplemental oxygen through the OxyMask or Venturi mask. Oxygen delivery was titrated to maintain SaO2 4% to 5% and 8% to 9% above baseline for two separate 30 min periods of stable breathing. Oxygen flow rate, partial pressure of inspired and expired oxygen (PO2) and carbon dioxide (PCO2), minute ventilation, heart rate, nasal and oral breathing, SaO2 and transcutaneous PCO2 were collected continuously. The study was repeated following alterations to the OxyMask design, which improved clearance of carbon dioxide. RESULTS: Thirteen patients, aged 28 to 79 years, were studied initially using the original OxyMask. Oxygen flow rate was lower, inspired PO2 was higher and expired PO2 was lower while using the OxyMask. Minute ventilation and inspired and expired PCO2 were significantly higher while using the OxyMask, whereas transcutaneous PCO2, heart rate and the ratio of nasal to oral breathing did not change significantly throughout the study. Following modification of the OxyMask, 13 additional patients, aged 18 to 79 years, were studied using the same protocol. The modified OxyMask provided a higher inspired PO2 at a lower flow rate, without evidence of carbon dioxide retention. CONCLUSIONS: Oxygen is delivered safely and more efficiently by the OxyMask than by the Venturi mask in stable oxygen-dependent patients. PMID:16896425

  8. Changes in carbon storage and oxygen production in forest timber ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-10-05

    Oct 5, 2009 ... treaties and processes, has shown itself around the world and in our country as the concept of planning and ... Key words: Carbon storage, oxygen production, forest management, geographic information systems, land cover change. .... biomass transformation factors developed for the forests in Turkey are ...

  9. Oxygen Saturation Surrounding Deep Water Formation Events in the Labrador Sea From Argo-O2 Data

    Science.gov (United States)

    Wolf, Mitchell K.; Hamme, Roberta C.; Gilbert, Denis; Yashayaev, Igor; Thierry, Virginie

    2018-04-01

    Deep water formation supplies oxygen-rich water to the deep sea, spreading throughout the ocean by means of the global thermohaline circulation. Models suggest that dissolved gases in newly formed deep water do not come to equilibrium with the atmosphere. However, direct measurements during wintertime convection are scarce, and the controls over the extent of these disequilibria are poorly quantified. Here we show that, when convection reached deeper than 800 m, oxygen in the Labrador Sea was consistently undersaturated at -6.1% to -7.6% at the end of convection. Deeper convection resulted in greater undersaturation, while convection ending later in the year resulted in values closer to equilibrium, from which we produce a predictive relationship. We use dissolved oxygen data from six profiling Argo floats in the Labrador Sea between 2003 and 2016, allowing direct observations of wintertime convection. Three of the six optode oxygen sensors displayed substantial average in situ drift of -3.03 μmol O2 kg-1 yr-1 (-0.94% O2 yr-1), which we corrected to stable deepwater oxygen values from repeat ship surveys. Observations of low oxygen intrusions during restratification and a simple mixing calculation demonstrate that lateral processes act to lower the oxygen inventory of the central Labrador Sea. This suggests that the Labrador Sea is a net sink for atmospheric oxygen, but uncertainties in parameterizing gas exchange limit our ability to quantify the net uptake. Our results constrain the oxygen concentration of newly formed Labrador Sea Water and allow more precise estimates of oxygen utilization and nutrient regeneration in this water mass.

  10. Toward translating near-infrared spectroscopy oxygen saturation data for the non-invasive prediction of spatial and temporal hemodynamics during exercise

    Science.gov (United States)

    Ellwein, Laura; Samyn, Margaret M.; Danduran, Michael; Schindler-Ivens, Sheila; Liebham, Stacy; LaDisa, John F.

    2016-01-01

    Image-based computational fluid dynamics (CFD) studies conducted at rest have shown that atherosclerotic plaque in the thoracic aorta (TA) correlates with adverse wall shear stress (WSS), but there is a paucity of such data under elevated flow conditions. We developed a pedaling exercise protocol to obtain phase contrast magnetic resonance imaging (PC-MRI) blood flow measurements in the TA and brachiocephalic arteries during three-tiered supine pedaling at 130%, 150%, and 170% of resting heart rate (HR), and relate these measurements to noninvasive tissue oxygen saturation (StO2) acquired by near-infrared spectroscopy (NIRS) while conducting the same protocol. Local quantification of WSS indices by CFD revealed low time-averaged WSS on the outer curvature of the ascending aorta and the inner curvature of the descending aorta (dAo) that progressively increased with exercise, but that remained low on the anterior surface of brachiocephalic arteries. High oscillatory WSS observed on the inner curvature of the aorta persisted during exercise as well. Results suggest locally continuous exposure to potentially deleterious indices of WSS despite benefits of exercise. Linear relationships between flow distributions and tissue oxygen extraction calculated from StO2 were found between the left common carotid versus cerebral tissue (r2=0.96) and the dAo versus leg tissue (r2=0.87). A resulting six-step procedure is presented to use NIRS data as a surrogate for exercise PC-MRI when setting boundary conditions for future CFD studies of the TA under simulated exercise conditions. Relationships and ensemble averaged PC-MRI inflow waveforms are provided in an online repository for this purpose. PMID:27376865

  11. First-in-human pilot study of a spatial frequency domain oxygenation imaging system

    Science.gov (United States)

    Gioux, Sylvain; Mazhar, Amaan; Lee, Bernard T.; Lin, Samuel J.; Tobias, Adam M.; Cuccia, David J.; Stockdale, Alan; Oketokoun, Rafiou; Ashitate, Yoshitomo; Kelly, Edward; Weinmann, Maxwell; Durr, Nicholas J.; Moffitt, Lorissa A.; Durkin, Anthony J.; Tromberg, Bruce J.; Frangioni, John V.

    2011-08-01

    Oxygenation measurements are widely used in patient care. However, most clinically available instruments currently consist of contact probes that only provide global monitoring of the patient (e.g., pulse oximetry probes) or local monitoring of small areas (e.g., spectroscopy-based probes). Visualization of oxygenation over large areas of tissue, without a priori knowledge of the location of defects, has the potential to improve patient management in many surgical and critical care applications. In this study, we present a clinically compatible multispectral spatial frequency domain imaging (SFDI) system optimized for surgical oxygenation imaging. This system was used to image tissue oxygenation over a large area (16×12 cm) and was validated during preclinical studies by comparing results obtained with an FDA-approved clinical oxygenation probe. Skin flap, bowel, and liver vascular occlusion experiments were performed on Yorkshire pigs and demonstrated that over the course of the experiment, relative changes in oxygen saturation measured using SFDI had an accuracy within 10% of those made using the FDA-approved device. Finally, the new SFDI system was translated to the clinic in a first-in-human pilot study that imaged skin flap oxygenation during reconstructive breast surgery. Overall, this study lays the foundation for clinical translation of endogenous contrast imaging using SFDI.

  12. Effect of temperature on the metabolism, behaviour and oxygen requirements of Sparus aurata

    NARCIS (Netherlands)

    Remen, M.; Nederlof, M.A.J.; Folkedal, O.; Thorsheim, G.; Sitjà-Bobadilla, A.; Pérez-Sánchez, J.; Oppedal, F.; Olsen, R.E.

    2015-01-01

    We investigated the effect of temperature on the limiting oxygen saturation (LOS) of gilthead sea bream Sparus aurata. This threshold was defined as the % O2 saturation where fish no longer upheld their routine metabolic rate (RMR, the metabolic rate of fed and active fish) during a progressive

  13. On the propagation of a coupled saturation and pressure front

    Energy Technology Data Exchange (ETDEWEB)

    Vasco, D. W.

    2010-12-01

    Using an asymptotic technique, valid for a medium with smoothly varying heterogeneity, I derive an expression for the velocity of a propagating, coupled saturation and pressure front. Due to the nonlinearity of the governing equations, the velocity of the propagating front depends upon the magnitude of the saturation and pressure changes across the front in addition to the properties of the medium. Thus, the expression must be evaluated in conjunction with numerical reservoir simulation. The propagation of the two-phase front is governed by the background saturation distribution, the saturation-dependent component of the fluid mobility, the porosity, the permeability, the capillary pressure function, the medium compressibility, and the ratio of the slopes of the relative permeability curves. Numerical simulation of water injection into a porous layer saturated with a nonaqueous phase liquid indicates that two modes of propagation are important. The fastest mode of propagation is a pressure-dominated disturbance that travels through the saturated layer. This is followed, much later, by a coupled mode with a large saturation change. These two modes are also observed in a simulation using a heterogeneous porous layer. A comparison between the propagation times estimated from the results of the numerical simulation and predictions from the asymptotic expression indicates overall agreement.

  14. Effects of Cyanate and 2,3-Diphosphoglycerate on Sickling RELATIONSHIP TO OXYGENATION

    Science.gov (United States)

    Jensen, Michael; Bunn, H. Franklin; Halikas, George; Kan, Yuet Wai; Nathan, David G.

    1973-01-01

    Cyanate and 2,3-diphosphoglycerate (2,3-DPG) both influence the oxygen affinity of hemoglobin. The studies presented here concern the effects of these compounds on the sickling phenomenon. The inhibitory effect of cyanate on sickling is largely due to the fact that it increases the percentage of oxyhemoglobin S at a given oxygen tension. In addition, cyanate inhibits sickling by a mechanism that is independent of oxygenation. In this paper, we have demonstrated that the viscosity of carbamylated sickle blood was lower than that of non-carbamylated controls at the same oxygen saturation. Furthermore, carbamylation resulted in an increase in the minimum concentration of deoxy-sickle hemoglobin required for gelation. Like cyanate, 2,3-DPG affected sickling of intact erythrocytes by two mechanisms. Since 2,3-DPG decreases the percentage of oxyhemoglobin S at a given oxygen tension, sickling is enhanced. In addition, 2,3-DPG had a direct effect. When the intracellular 2,3-DPG concentration was increased in vitro, a greater percentage of cells were sickled at a given oxygen saturation. Conversely, sickling was inhibited in cells in which 2,3-DPG was artificially lowered. These data indicate that the enhancement of sickling by 2,3-DPG is in part independent of its influence on oxygen affinity. PMID:4729047

  15. Asymmetry of quadriceps muscle oxygenation during elite short-track speed skating.

    Science.gov (United States)

    Hesford, Catherine Mary; Laing, Stewart J; Cardinale, Marco; Cooper, Chris E

    2012-03-01

    It has been suggested that, because of the low sitting position in short-track speed skating, muscle blood flow is restricted, leading to decreases in tissue oxygenation. Therefore, wearable wireless-enabled near-infrared spectroscopy (NIRS) technology was used to monitor changes in quadriceps muscle blood volume and oxygenation during a 500-m race simulation in short-track speed skaters. Six elite skaters, all of Olympic standard (age = 23 ± 1.8 yr, height = 1.8 ± 0.1 m, mass = 80.1 ± 5.7 kg, midthigh skinfold thickness = 7 ± 2 mm), were studied. Subjects completed a 500-m race simulation time trial (TT). Whole-body oxygen consumption was simultaneously measured with muscle oxygenation in right and left vastus lateralis as measured by NIRS. Mean time for race completion was 44.8 ± 0.4 s. VO2 peaked 20 s into the race. In contrast, muscle tissue oxygen saturation (TSI%) decreased and plateaued after 8 s. Linear regression analysis showed that right leg TSI% remained constant throughout the rest of the TT (slope value = 0.01), whereas left leg TSI% increased steadily (slope value = 0.16), leading to a significant asymmetry (P skating has implications for training and performance.

  16. Inner Retinal Oxygen Extraction Fraction in Response to Light Flicker Stimulation in Humans

    Science.gov (United States)

    Felder, Anthony E.; Wanek, Justin; Blair, Norman P.; Shahidi, Mahnaz

    2015-01-01

    Purpose Light flicker has been shown to stimulate retinal neural activity, increase blood flow, and alter inner retinal oxygen metabolism (MO2) and delivery (DO2). The purpose of the study was to determine the change in MO2 relative to DO2 due to light flicker stimulation in humans, as assessed by the inner retinal oxygen extraction fraction (OEF). Methods An optical imaging system, based on a modified slit lamp biomicroscope, was developed for simultaneous measurements of retinal vascular diameter (D) and oxygen saturation (SO2). Retinal images were acquired in 20 healthy subjects before and during light flicker stimulation. Arterial and venous D (DA and DV) and SO2 (SO2A and SO2V) were quantified within a circumpapillary region. Oxygen extraction fraction was defined as the ratio of MO2 to DO2 and was calculated as (SO2A − SO2V)/SO2A. Reproducibility of measurements was assessed. Results Coefficients of variation and intraclass correlation coefficients of repeated measurements were <5% and ≥0.83, respectively. During light flicker stimulation, DA, DV , and SO2V significantly increased (P ≤ 0.004). Oxygen extraction fraction was 0.37 ± 0.08 before light flicker and significantly decreased to 0.31 ± 0.07 during light flicker (P = 0.001). Conclusions Oxygen extraction fraction before and during light flicker stimulation is reported in human subjects for the first time. Oxygen extraction fraction decreased during light flicker stimulation, indicating the change in DO2 exceeded that of MO2. This technology is potentially useful for the detection of changes in OEF response to light flicker in physiological and pathological retinal conditions. PMID:26469748

  17. Discrepancies between measured changes of radiobiological hypoxic fraction and oxygen tension monitoring using two assay systems

    International Nuclear Information System (INIS)

    Sasai, K.; Brown, J.M.

    1994-01-01

    This study was conducted to assess the ability of computerized pO 2 histography to measure changes in tumor oxygenation produced by low oxygen breathing. Female syngeneic C3H/Km mice bearing SCC VII/St carcinomas were used in these experiments. Changes in tumor oxygenation produced by the mice breathing 10% oxygen were assessed with computerized pO2 histography, 3 H-misonidazole binding, and the paired survival curve assay of radiosensitivity. The hypoxic cell fraction of the tumors in mice breathing 10% oxygen was 3.1 times higher than that of tumors in mice breathing normal air determined by an in vivo-in vitro clonogenic assay. Binding of radiolabeled misonidazole to the tumors in mice breathing 10% oxygen was also significantly higher than that to tumors in mice breathing normal air (p 2 value for the tumor. The number of pO 2 readings lower than 5 mmHg in the tumor was not affected by the 10% oxygen breathing. These findings indicate that increases in radiobiological hypoxic fraction produced by lower blood oxygen levels may not correlate well with the results of polarographic measurements of tumor pO 2 levels. 29 refs., 4 figs., 1 tab

  18. Processing of pulse oximeter signals using adaptive filtering and autocorrelation to isolate perfusion and oxygenation components

    Science.gov (United States)

    Ibey, Bennett; Subramanian, Hariharan; Ericson, Nance; Xu, Weijian; Wilson, Mark; Cote, Gerard L.

    2005-03-01

    A blood perfusion and oxygenation sensor has been developed for in situ monitoring of transplanted organs. In processing in situ data, motion artifacts due to increased perfusion can create invalid oxygenation saturation values. In order to remove the unwanted artifacts from the pulsatile signal, adaptive filtering was employed using a third wavelength source centered at 810nm as a reference signal. The 810 nm source resides approximately at the isosbestic point in the hemoglobin absorption curve where the absorbance of light is nearly equal for oxygenated and deoxygenated hemoglobin. Using an autocorrelation based algorithm oxygenation saturation values can be obtained without the need for large sampling data sets allowing for near real-time processing. This technique has been shown to be more reliable than traditional techniques and proven to adequately improve the measurement of oxygenation values in varying perfusion states.

  19. A multiplexed electronic architecture for opto-electronic patch sensor to effectively monitor heart rate and oxygen saturation

    Science.gov (United States)

    Yan, Liangwen; Hu, Sijung; Alharbi, Samah; Blanos, Panagiotis

    2018-02-01

    To effectively capture human vital signs, a multi-wavelength optoelectronic patch sensor (MOEPS), together with a schematic architecture of electronics, was developed to overcome the drawbacks of present photoplethysmographic (PPG) sensors. To obtain a better performance of in vivo physiological measurement, the optimal illuminations, i.e., light emitting diodes (LEDs) in the MOEPS, whose wavelength is automatically adjusted to each specific subject, were selected to capture better PPG signals. A multiplexed electronic architecture has been well established to properly drive the MOEPS and effectively capture pulsatile waveforms at rest. The protocol was designed to investigate its performance with the participation of 11 healthy subjects aged between 18 and 30. The signals obtained from green (525nm) and orange (595nm) illuminations were used to extract heart rate (HR) and oxygen saturation (SpO2%). These results were compared with data, simultaneously acquired, from a commercial ECG and a pulse oximeter. Considering the difficulty for current devices to attain the SpO2%, a new computing method, to obtain the value of SpO2%, is proposed depended on the green and orange wavelength illuminations. The values of SpO2% between the MOEPS and the commercial Pulse Oximeter devics showed that the results were in good agreement. The values of HR showed close correlation between commercial devices and the MOEPS (HR: r1=0.994(Green); r2=0.992(Orange); r3=0.975(Red); r4=0.990(IR)).

  20. A Novel β-Globin Chain Hemoglobin Variant, Hb Allentown [β137(H15)Val→Trp (GTG>TGG) HBB: c.412_413delinsTG, p.Val138Trp], Associated with Low Oxygen Saturation, Intermittent Aplastic Crises and Splenomegaly.

    Science.gov (United States)

    Collier, Anderson B; Coon, Lea M; Monteleone, Philip; Umaru, Samuel; Swanson, Kenneth C; Hoyer, James D; Oliveira, Jennifer L

    2016-01-01

    Hemoglobin (Hb) variants may be associated with low oxygen saturation and exacerbated episodes of anemia from common stressors such as viral infections. These attributes frequently cause increased clinical concern and unnecessary and expensive testing if not considered early in the evaluation of the patient. Some clinically significant Hb variants result in a normal Hb electrophoresis result, which can be method-dependent. Herein we describe a patient with low oxygen saturation and a history of hemolytic anemia who was subsequently found to carry a novel, unstable β-globin variant that we have named Hb Allentown [β137(H15)Val→Trp (GTG>TGG) HBB: c.412_413delinsTG, p.Val138Trp] for the place of identification of the variant. Hb Allentown is formed by a rare double nucleotide substitution within the same codon. Additionally, positive identification of rare Hb variants characterized by a single method is discouraged, as the Hb variant was misclassified as Hb S-South End or β6(A3)Glu→Val;β132(H10)Lys→Asn (HBB: c.[20A > T;399A > C]) by the initial laboratory.

  1. A fibre optic oxygen sensor that detects rapid PO2 changes under simulated conditions of cyclical atelectasis in vitro.

    Science.gov (United States)

    Formenti, Federico; Chen, Rongsheng; McPeak, Hanne; Matejovic, Martin; Farmery, Andrew D; Hahn, Clive E W

    2014-01-15

    Two challenges in the management of Acute Respiratory Distress Syndrome are the difficulty in diagnosing cyclical atelectasis, and in individualising mechanical ventilation therapy in real-time. Commercial optical oxygen sensors can detect [Formula: see text] oscillations associated with cyclical atelectasis, but are not accurate at saturation levels below 90%, and contain a toxic fluorophore. We present a computer-controlled test rig, together with an in-house constructed ultra-rapid sensor to test the limitations of these sensors when exposed to rapidly changing [Formula: see text] in blood in vitro. We tested the sensors' responses to simulated respiratory rates between 10 and 60 breaths per minute. Our sensor was able to detect the whole amplitude of the imposed [Formula: see text] oscillations, even at the highest respiratory rate. We also examined our sensor's resistance to clot formation by continuous in vivo deployment in non-heparinised flowing animal blood for 24h, after which no adsorption of organic material on the sensor's surface was detectable by scanning electron microscopy. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Oxygen-Partial-Pressure Sensor for Aircraft Oxygen Mask

    Science.gov (United States)

    Kelly, Mark; Pettit, Donald

    2003-01-01

    A device that generates an alarm when the partial pressure of oxygen decreases to less than a preset level has been developed to help prevent hypoxia in a pilot or other crewmember of a military or other high-performance aircraft. Loss of oxygen partial pressure can be caused by poor fit of the mask or failure of a hose or other component of an oxygen distribution system. The deleterious physical and mental effects of hypoxia cause the loss of a military aircraft and crew every few years. The device is installed in the crewmember s oxygen mask and is powered via communication wiring already present in all such oxygen masks. The device (see figure) includes an electrochemical sensor, the output potential of which is proportional to the partial pressure of oxygen. The output of the sensor is amplified and fed to the input of a comparator circuit. A reference potential that corresponds to the amplified sensor output at the alarm oxygen-partial-pressure level is fed to the second input of the comparator. When the sensed partial pressure of oxygen falls below the minimum acceptable level, the output of the comparator goes from the low state (a few millivolts) to the high state (near the supply potential, which is typically 6.8 V for microphone power). The switching of the comparator output to the high state triggers a tactile alarm in the form of a vibration in the mask, generated by a small 1.3-Vdc pager motor spinning an eccentric mass at a rate between 8,000 and 10,000 rpm. The sensation of the mask vibrating against the crewmember s nose is very effective at alerting the crewmember, who may already be groggy from hypoxia and is immersed in an environment that is saturated with visual cues and sounds. Indeed, the sensation is one of rudeness, but such rudeness could be what is needed to stimulate the crewmember to take corrective action in a life-threatening situation.

  3. Interplay of tumor vascular oxygenation and tumor pO2 observed using near-infrared spectroscopy, an oxygen needle electrode, and 19F MR pO2 mapping.

    Science.gov (United States)

    Kim, Jae G; Zhao, Dawen; Song, Yulin; Constantinescu, Anca; Mason, Ralph P; Liu, Hanli

    2003-01-01

    This study investigates the correlation of tumor blood oxygenation and tumor pO(2) with respect to carbogen inhalation. After having refined and validated the algorithms for calculating hemoglobin concentrations, we used near-infrared spectroscopy (NIRS) to measure changes of oxygenated hemoglobin concentration (delta[HbO(2)]) and used an oxygen needle electrode and (19)F MRI for pO(2) measurements in tumors. The measurements were taken from Dunning prostate R3327 tumors implanted in rats, while the anesthetized rats breathed air or carbogen. The NIRS results from tumor measurements showed significant changes in tumor vascular oxygenation in response to carbogen inhalation, while the pO(2) electrode results showed an apparent heterogeneity for tumor pO(2) response to carbogen inhalation, which was also confirmed by (19)F MR pO(2) mapping. Furthermore, we developed algorithms to estimate hemoglobin oxygen saturation, sO(2), during gas intervention based on the measured values of delta[HbO(2)] and pO(2). The algorithms have been validated through a tissue-simulating phantom and used to estimate the values of sO(2) in the animal tumor measurement based on the NIRS and global mean pO(2) values. This study demonstrates that the NIRS technology can provide an efficient, real-time, noninvasive approach to monitoring tumor physiology and is complementary to other techniques, while it also demonstrates the need for an NIR imaging technique to study spatial heterogeneity of tumor vasculature under therapeutic interventions. Copyright 2003 Society of Photo-Optical Instrumentation Engineers

  4. Reactions of oxygen and hydrogen with liquid sodium - a critical survey

    International Nuclear Information System (INIS)

    Ullmann, H.

    1982-01-01

    The fundamentals of solvation chemistry are presented with appropriate components formulated. Methods of investigation and kinetics of the reactions are described. The hydrogen equilibrium pressure and saturation solubilities are described. The chemical equilibrium between O and H in solution is presented with detailed tabulation of the saturation solutions of oxygen, hydrogen and hydroxide in liquid sodium. Agreements and differences with the literature are presented

  5. Spontaneous calcium waves in Bergman glia increase with age and hypoxia and may reduce tissue oxygen

    DEFF Research Database (Denmark)

    Mathiesen, Claus; Brazhe, Alexey; Thomsen, Kirsten Joan

    2013-01-01

    Glial calcium (Ca(2+)) waves constitute a means to spread signals between glial cells and to neighboring neurons and blood vessels. These waves occur spontaneously in Bergmann glia (BG) of the mouse cerebellar cortex in vivo. Here, we tested three hypotheses: (1) aging and reduced blood oxygen sa...... activity during aging, as well as low resting brain oxygen tension, suggests a relationship between glial waves, brain energy homeostasis, and pathology.......Glial calcium (Ca(2+)) waves constitute a means to spread signals between glial cells and to neighboring neurons and blood vessels. These waves occur spontaneously in Bergmann glia (BG) of the mouse cerebellar cortex in vivo. Here, we tested three hypotheses: (1) aging and reduced blood oxygen...... saturation alters wave activity; (2) glial Ca(2+) waves change cerebral oxygen metabolism; and (3) neuronal and glial wave activity is correlated. We used two-photon microscopy in the cerebellar cortexes of adult (8- to 15-week-old) and aging (48- to 80-week-old) ketamine-anesthetized mice after bolus...

  6. Angiotensin-converting enzyme genotype and arterial oxygen saturation at high altitude in Peruvian Quechua.

    Science.gov (United States)

    Bigham, Abigail W; Kiyamu, Melisa; León-Velarde, Fabiola; Parra, Esteban J; Rivera-Ch, Maria; Shriver, Mark D; Brutsaert, Tom D

    2008-01-01

    The I-allele of the angiotensin-converting enzyme (ACE) gene insertion/deletion (I/D) polymorphism has been associated with performance benefits at high altitude (HA). In n = 142 young males and females of largely Quechua origins in Peru, we evaluated 3 specific hypotheses with regard to the HA benefits of the I-allele: (1) the I-allele is associated with higher arterial oxygen saturation (Sa(O(2))) at HA, (2) the I-allele effect depends on the acclimatization state of the subjects, and (3) the putative I-allele effect on Sa(O(2)) is mediated by the isocapnic hypoxic ventilatory response (HVR, l/min(1)/% Sa(O(2))(1)). The subject participants comprised two different study groups including BLA subjects (born at low altitude) who were lifelong sea-level residents transiently exposed to hypobaric hypoxia (<24 h) and BHA subjects (born at HA) who were lifelong residents of HA. To control for the possibility of population stratification, Native American ancestry proportion (NAAP) was estimated as a covariate for each individual using a panel of 70 ancestry-informative molecular markers (AIMS). At HA, resting and exercise Sa(O(2)) was strongly associated with the ACE genotype, p = 0.008 with approximately 4% of the total variance in Sa(O(2)) attributed to ACE genotype. Moreover, I/I individuals maintained approximately 2.3 percentage point higher Sa(O(2)) compared to I/D and D/D. This I-allele effect was evident in both BLA and BHA groups, suggesting that acclimatization state has little influence on the phenotypic expression of the ACE gene. Finally, ACE genotype was not associated with the isocapnic HVR, although HVR had a strong independent effect on Sa(O(2)) (p = 0.001). This suggests that the I-allele effect on Sa(O(2)) is not mediated by the peripheral control of breathing, but rather by some other central cardiopulmonary effect of the ACE gene on the renin-angiotensin-aldosterone system (RAAS).

  7. Interplay of crystal fractionation, sulfide saturation and oxygen fugacity on the iron isotope composition of arc lavas: An example from the Marianas

    Science.gov (United States)

    Williams, H. M.; Prytulak, J.; Woodhead, J. D.; Kelley, K. A.; Brounce, M.; Plank, T.

    2018-04-01

    Subduction zone systems are central to a multitude of processes from the evolution of the continental crust to the concentration of metals into economically viable deposits. The interplay between oxygen fugacity, sulfur saturation, fluid exsolution and fractionating mineral assemblages that gives rise to typical arc magma chemical signatures is, however, still poorly understood and novel geochemical approaches are required to make further progress. Here we examine a well-characterized suite of arc lavas from the Marianas (W. Pacific) for their stable Fe isotope composition. In agreement with previous work and mass balance considerations, contributions from sediments and/or fluids are shown to have negligible effect on Fe isotopes. Instead, we focus on disentangling processes occurring during basalt through dacite differentiation using a sample suite from the island of Anatahan. Anatahan whole rock Fe isotope compositions (δ57Fe) range from -0.05 ± 0.05 to 0.17 ± 0.03 (2 S.D.)‰. A fractionation model is constructed, where three distinct stages of differentiation are required to satisfy the combined major and trace element and isotopic observations. In particular, the sequestration of isotopically heavy Fe into magnetite and isotopically light Fe into sulfide melts yields important constraints. The data require that lavas are first undersaturated with respect to crystalline or molten sulfide, followed by the crystallisation of magnetite, which then triggers late sulfide saturation. The model demonstrates that the final stage of removal of liquid or crystalline sulfide can effectively sequester Cu (and presumably other chalcophiles) and that late stage exsolution of magmatic fluids or brines may not be required to do this, although these processes are not mutually exclusive. Finally, the new Fe isotope data are combined with previous Tl-Mo-V stable isotope determinations on the same samples. Importantly, the multi-valent transition metal stable isotope systems of

  8. Withdrawal from high-carbohydrate, high-saturated-fat diet changes saturated fat distribution and improves hepatic low-density-lipoprotein receptor expression to ameliorate metabolic syndrome in rats.

    Science.gov (United States)

    Hazarika, Ankita; Kalita, Himadri; Kalita, Mohan Chandra; Devi, Rajlakshmi

    2017-06-01

    The "lipid hypothesis" determined that saturated fatty acid (SFA) raises low-density lipoprotein cholesterol, thereby increasing the risk for metabolic syndrome (MetS). The aim of this study was to investigate the effect of subchronic withdrawal from a high-carbohydrate, high-saturated fat (HCHF) diet during MetS with reference to changes in deleterious SFA (C12:0, lauric acid; C14:0, myristic acid; C16:0, palmitic acid; C18:0, stearic acid) distribution in liver, white adipose tissue (WAT), and feces. MetS induced by prolonged feeding of an HCHF diet in Wistar albino rat is used as a model of human MetS. The MetS-induced rats were withdrawn from the HCHF diet and changed to a basal diet for final 4 wk of the total experimental duration of 16 wk. SFA distribution in target tissues and hepatic low-density lipoprotein receptor (LDLr) expression were analyzed. Analyses of changes in SFA concentration of target tissues indicate that C16:0 and C18:0 reduced in WAT and liver after withdrawal of the HCHF diet. There was a significant (P < 0.001) decrease in fecal C12:0 with HCHF feeding, which significantly (P < 0.01) increased after withdrawal of this diet. Also, an improvement in expression of hepatic LDLr was observed after withdrawal of HCHF diet. The prolonged consumption of an HCHF diet leads to increased SFA accumulation in liver and WAT, decreased SFA excretion, and reduced hepatic LDLr expression during MetS, which is prominently reversed after subchronic withdrawal of the HCHF diet. This can contribute to better understanding of the metabolic fate of dietary SFA during MetS and may apply to the potential reversal of complications by the simple approach of nutritional modification. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Electrical conductivity modeling in fractal non-saturated porous media

    Science.gov (United States)

    Wei, W.; Cai, J.; Hu, X.; Han, Q.

    2016-12-01

    The variety of electrical conductivity in non-saturated conditions is important to study electric conduction in natural sedimentary rocks. The electrical conductivity in completely saturated porous media is a porosity-function representing the complex connected behavior of single conducting phases (pore fluid). For partially saturated conditions, the electrical conductivity becomes even more complicated since the connectedness of pore. Archie's second law is an empirical electrical conductivity-porosity and -saturation model that has been used to predict the formation factor of non-saturated porous rock. However, the physical interpretation of its parameters, e.g., the cementation exponent m and the saturation exponent n, remains questionable. On basis of our previous work, we combine the pore-solid fractal (PSF) model to build an electrical conductivity model in non-saturated porous media. Our theoretical porosity- and saturation-dependent models contain endmember properties, such as fluid electrical conductivities, pore fractal dimension and tortuosity fractal dimension (representing the complex degree of electrical flowing path). We find the presented model with non-saturation-dependent electrical conductivity datasets indicate excellent match between theory and experiments. This means the value of pore fractal dimension and tortuosity fractal dimension change from medium to medium and depends not only on geometrical properties of pore structure but also characteristics of electrical current flowing in the non-saturated porous media.

  10. Intracapillary HbO2 saturations in murine tumours and human tumour xenografts measured by cryospectrophotometry: relationship to tumour volume, tumour pH and fraction of radiobiologically hypoxic cells.

    Science.gov (United States)

    Rofstad, E K; Fenton, B M; Sutherland, R M

    1988-05-01

    Frequency distributions for intracapillary HbO2 saturation were determined for two murine tumour lines (KHT, RIF-1) and two human ovarian carcinoma xenograft lines (MLS, OWI) using a cryospectrophotometric method. The aim was to search for possible relationships between HbO2 saturation status and tumour volume, tumour pH and fraction of radiobiologically hypoxic cells. Tumour pH was measured by 31P NMR spectroscopy. Hypoxic fractions were determined from cell survival curves for tumours irradiated in vivo and assayed in vitro. Tumours in the volume range 100-4000 mm3 were studied and the majority of the vessels were found to have HbO2 saturations below 10%. The volume-dependence of the HbO2 frequency distributions differed significantly among the four tumour lines; HbO2 saturation status decreased with increasing tumour volume for the KHT, RIF-1 and MLS lines and was independent of tumour volume for the OWI line. The data indicated that the rate of decrease in HbO2 saturation status during tumour growth was related to the rate of development of necrosis. The volume-dependence of tumour pH was very similar to that of the HbO2 saturation status for all tumour lines. Significant correlations were therefore found between HbO2 saturation status and tumour pH, both within tumour lines and across the four tumour lines, reflecting that the volume-dependence of both parameters probably was a compulsory consequence of reduced oxygen supply conditions during tumour growth. Hypoxic fraction increased during tumour growth for the KHT, RIF-1 and MLS lines and was volume-independent for the OWI line, suggesting a relationship between HbO2 saturation status and hypoxic fraction within tumour lines. However, there was no correlation between these two parameters across the four tumour lines, indicating that the hypoxic fraction of a tumour is not determined only by the oxygen supply conditions; other parameters may also be important, e.g. oxygen diffusivity, rate of oxygen

  11. The combined effects of acidification and hypoxia on pH and aragonite saturation in the coastal waters of the California current ecosystem and the northern Gulf of Mexico

    Science.gov (United States)

    Feely, Richard A.; Okazaki, Remy R.; Cai, Wei-Jun; Bednaršek, Nina; Alin, Simone R.; Byrne, Robert H.; Fassbender, Andrea

    2018-01-01

    Inorganic carbon chemistry data from the surface and subsurface waters of the West Coast of North America have been compared with similar data from the northern Gulf of Mexico to demonstrate how future changes in CO2 emissions will affect chemical changes in coastal waters affected by respiration-induced hypoxia ([O2] ≤ 60 μmol kg-1). In surface waters, the percentage change in the carbon parameters due to increasing CO2 emissions are very similar for both regions even though the absolute decrease in aragonite saturation is much higher in the warmer waters of the Gulf of Mexico. However, in subsurface waters the changes are enhanced due to differences in the initial oxygen concentration and the changes in the buffer capacity (i.e., increasing Revelle Factor) with increasing respiration from the oxidation of organic matter, with the largest impacts on pH and CO2 partial pressure (pCO2) occurring in the colder West Coast waters. As anthropogenic CO2 concentrations begin to build up in subsurface waters, increased atmospheric CO2 will expose organisms to hypercapnic conditions (pCO2 >1000 μatm) within subsurface depths. Since the maintenance of the extracellular pH appears as the first line of defense against external stresses, many biological response studies have been focused on pCO2-induced hypercapnia. The extent of subsurface exposure will occur sooner and be more widespread in colder waters due to their capacity to hold more dissolved oxygen and the accompanying weaker acid-base buffer capacity. Under present conditions, organisms in the West Coast are exposed to hypercapnic conditions when oxygen concentrations are near 100 μmol kg-1 but will experience hypercapnia at oxygen concentrations of 260 μmol kg-1 by year 2100 under the highest elevated-CO2 conditions. Hypercapnia does not occur at present in the Gulf of Mexico but will occur at oxygen concentrations of 170 μmol kg-1 by the end of the century under similar conditions. The aragonite saturation

  12. Oxygen titration strategies in chronic neonatal lung disease.

    Science.gov (United States)

    Primhak, Robert

    2010-09-01

    The history of oxygen therapy in neonatology has been littered with error. Controversies remain in a number of areas of oxygen therapy, including targets and strategies in supplemental oxygen therapy in Chronic Neonatal Lung Disease (CNLD). This article reviews some of these controversies, and makes some recommendations based on the available evidence. In graduates of neonatal units who are left with CNLD, oxygen saturation should be kept above 93-95%, with levels below 90% being avoided as far as possible. Titration of oxygen should be done using oximetry recordings which include periods of different activities. Weaning of oxygen supplementation should only be done based on satisfactory recordings during a trial of a lower flow. There is insufficient evidence to say whether weaning for increasing hours a day or stepwise weaning to a continuous lower flow is a better method. Copyright 2010 Elsevier Ltd. All rights reserved.

  13. Non-invasive monitoring of tissue oxygenation during laparoscopic donor nephrectomy

    Directory of Open Access Journals (Sweden)

    Kirk Allan D

    2008-04-01

    Full Text Available Abstract Background Standard methods for assessment of organ viability during surgery are typically limited to visual cues and tactile feedback in open surgery. However, during laparoscopic surgery, these processes are impaired. This is of particular relevance during laparoscopic renal donation, where the condition of the kidney must be optimized despite considerable manipulation. However, there is no in vivo methodology to monitor renal parenchymal oxygenation during laparoscopic surgery. Methods We have developed a method for the real time, in vivo, whole organ assessment of tissue oxygenation during laparoscopic nephrectomy to convey meaningful biological data to the surgeon during laparoscopic surgery. We apply the 3-CCD (charge coupled device camera to monitor qualitatively renal parenchymal oxygenation with potential real-time video capability. Results We have validated this methodology in a porcine model across a range of hypoxic conditions, and have then applied the method during clinical laparoscopic donor nephrectomies during clinically relevant pneumoperitoneum. 3-CCD image enhancement produces mean region of interest (ROI intensity values that can be directly correlated with blood oxygen saturation measurements (R2 > 0.96. The calculated mean ROI intensity values obtained at the beginning of the laparoscopic nephrectomy do not differ significantly from mean ROI intensity values calculated immediately before kidney removal (p > 0.05. Conclusion Here, using the 3-CCD camera, we qualitatively monitor tissue oxygenation. This means of assessing intraoperative tissue oxygenation may be a useful method to avoid unintended ischemic injury during laparoscopic surgery. Preliminary results indicate that no significant changes in renal oxygenation occur as a result of pneumoperitoneum.

  14. Circulation and oxygen cycling in the Mediterranean Sea: Sensitivity to future climate change

    Science.gov (United States)

    Powley, Helen R.; Krom, Michael D.; Van Cappellen, Philippe

    2016-11-01

    Climate change is expected to increase temperatures and decrease precipitation in the Mediterranean Sea (MS) basin, causing substantial changes in the thermohaline circulation (THC) of both the Western Mediterranean Sea (WMS) and Eastern Mediterranean Sea (EMS). The exact nature of future circulation changes remains highly uncertain, however, with forecasts varying from a weakening to a strengthening of the THC. Here we assess the sensitivity of dissolved oxygen (O2) distributions in the WMS and EMS to THC changes using a mass balance model, which represents the exchanges of O2 between surface, intermediate, and deep water reservoirs, and through the Straits of Sicily and Gibraltar. Perturbations spanning the ranges in O2 solubility, aerobic respiration kinetics, and THC changes projected for the year 2100 are imposed to the O2 model. In all scenarios tested, the entire MS remains fully oxygenated after 100 years; depending on the THC regime, average deep water O2 concentrations fall in the ranges 151-205 and 160-219 µM in the WMS and EMS, respectively. On longer timescales (>1000 years), the scenario with the largest (>74%) decline in deep water formation rate leads to deep water hypoxia in the EMS but, even then, the WMS deep water remains oxygenated. In addition, a weakening of THC may result in a negative feedback on O2 consumption as supply of labile dissolved organic carbon to deep water decreases. Thus, it appears unlikely that climate-driven changes in THC will cause severe O2 depletion of the deep water masses of the MS in the foreseeable future.

  15. Changes in the composition and properties of Ashalchinskoye bitumen-saturated sandstones when exposed to water vapor

    Science.gov (United States)

    Korolev, E.; Eskin, A.; Kolchugin, A.; Morozov, V.; Khramchenkov, M.; Gabdelvalieva, R.

    2018-05-01

    bitumen saturated sandstones there are the processes of transformation of clay minerals. Mixed-illite-montmorillonite phase is primarily exposed to changes. In this case we fix initial stage of the destruction of polycrystalline particles mixed-mineral. Reducing the size of clay minerals particles along the normal to the layers (L001) is the result from lower energy costs of delamination and disintegration the crystallites along this direction, in comparison with others. Thus, using of SAGD technology at exploitation of Ashalchinskoye bitumen saturated reservoir will be followed by acidification of the pore fluid, activation processes of dissolution calcite cement and transformation of mixed-layers clays minerals.

  16. Changes in carbon storage and oxygen production in forest timber ...

    African Journals Online (AJOL)

    Decrease in forest areas world wide and the damaging of its structures is hazardous to human health, hinders and dries up the spread of oxygen in the air and also destroys carbon storage. In recent years, global warming and changes in climates depending on the increase in the green house gases have been affecting the ...

  17. The formation of non-oxidic oxygen phases on Ru(0001). From the first stages of the oxygen take-up to oxidation

    International Nuclear Information System (INIS)

    Blume, R.

    2005-01-01

    The aim of the thesis presented here was the investigation of the formation of non oxidic oxygen phases on the Ru(0001) surface. Smooth and defect rich surfaces were exposed to high oxygen pressures (up to 1 bar) at moderate temperatures (550 K). The characterisation was performed under UHV conditions using Thermal Desorption Spectroscopy (TDS), Scanning Photoemission Microscopy (SPEM), Thermal Energy Atomic Scattering (TEAS), Ultraviolett Photoelectron Spectroscopy (UPS) and Low Energy Electron Diff raction (LEED) as well as In situ by the In Situ X-Ray Photoelectron Spectroscopy (In Situ XPS). The application of this Low Temperature preparation procedure (LT) leads to an Oxygen uptake up to 3 MLE of ''subsurface'' oxygen into a smooth Ru(0001) surface without the typical indications of oxidation (MLE: Monolayer Equivalent). The accumulation of oxygen beneath the surface starts immediatly after the completion of a full chemisorbed layer. Here, the local saturation of the adsorbed oxygen is the decisive step. Diff usion of oxygen directly through the chemisorbed layer only slightly contributes to the overall uptake. Oxygen is mostly accomodated in the vicinity of the surface via surface defects which has been shown on defect rich surfaces created by mild Ar+ sputtering. The maximum oxygen capacity is 10 Atoms/Defect. The uptake is thermally activated with an activation energy of 0.15 eV. The oxygen uptake causes a massive structural change of at least the top two ruthenium layers. Whereas the ruthenium atoms of the first layer are coordinated with up to four, those of the second layer are coordinated with up to two oxygen atoms. These binding condition are metastable and can be changed by annealing the surface. With reaching the desorption temperature two distinct desorption peaks are observed with TDS. For an accumulation of about 0.5 MLE of ''subsurface'' oxygen the desorption proceeds exclusively at the characteristic temperature of the chemisorbed layer at 1040

  18. Oxidation of monovacancies in graphene by oxygen molecules

    KAUST Repository

    Kaloni, Thaneshwor P.; Cheng, Yingchun; Faccio, R.; Schwingenschlö gl, Udo

    2011-01-01

    We study the oxidation of monovacancies in graphene by oxygen molecules using first principles calculations. In particular, we address the local magnetic moments which develop at monovacancies and show that they remain intact when a molecule is adsorbed such that the dangling carbon bonds are not fully saturated. However, the lowest energy configuration does not maintain dangling bonds and is found to be semiconducting. Our data can explain the experimentally observed behavior of graphene under exposure to an oxygen plasma.

  19. Oxidation of monovacancies in graphene by oxygen molecules

    KAUST Repository

    Kaloni, Thaneshwor P.

    2011-10-14

    We study the oxidation of monovacancies in graphene by oxygen molecules using first principles calculations. In particular, we address the local magnetic moments which develop at monovacancies and show that they remain intact when a molecule is adsorbed such that the dangling carbon bonds are not fully saturated. However, the lowest energy configuration does not maintain dangling bonds and is found to be semiconducting. Our data can explain the experimentally observed behavior of graphene under exposure to an oxygen plasma.

  20. Misalignment of disposable pulse oximeter probes results in false saturation readings that influence anesthetic management.

    Science.gov (United States)

    Guan, Zhonghui; Baker, Keith; Sandberg, Warren S

    2009-11-01

    We report a small case series in which misaligned disposable pulse oximeter sensors gave falsely low saturation readings. In each instance, the sensor performed well during preinduction oxygen administration and the early part of the case, most notably by producing a plethysmographic trace rated as high quality by the oximeter software. The reported pulse oximeter oxygen saturation eventually decreased to concerning levels in each instance, but the anesthesiologists, relying on the reported high-quality signal, initially sought other causes for apparent hypoxia. They undertook maneuvers and diagnostic procedures later deemed unnecessary. When the malpositioned sensors were discovered and repositioned, the apparent hypoxia was quickly relieved in each case. We then undertook a survey of disposable oximeter sensors as patients entered the recovery room, and discovered malposition of more than 1 cm in approximately 20% of all sensors, without apparent consequence. We conclude that the technology is quite robust, but that the diagnosis of apparent hypoxia should include a quick check of oximeter position early on.

  1. Significant room-temperature ferromagnetism in porous ZnO films: The role of oxygen vacancies

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Xue; Liu, Huiyuan [College of Physics Science & Information Engineering, Hebei Normal University, Shijiazhuang 050024 (China); Key Laboratory of Advanced Films of Hebei Province, Shijiazhuang 050024 (China); Sun, Huiyuan, E-mail: huiyuansun@126.com [College of Physics Science & Information Engineering, Hebei Normal University, Shijiazhuang 050024 (China); Key Laboratory of Advanced Films of Hebei Province, Shijiazhuang 050024 (China); Liu, Lihu; Jia, Xiaoxuan [College of Physics Science & Information Engineering, Hebei Normal University, Shijiazhuang 050024 (China); Key Laboratory of Advanced Films of Hebei Province, Shijiazhuang 050024 (China)

    2015-10-15

    Graphical abstract: - Highlights: • Porous ZnO films were deposited on porous anodic alumina substrates. • Significant ferromagnetism (FM) has been observed in porous ZnO films (110 emu/cm{sup 3}). • The strong magnetic anisotropy was observed in the porous ZnO films. • The origin of FM is attributed to the oxygen vacancy with a local magnetic moment. - Abstract: Pure porous ZnO films were prepared by direct current reactive magnetron sputtering on porous anodic alumina substrates. Remarkably large room-temperature ferromagnetism was observed in the films. The highest saturation moment along the out-of-plane direction was about 110 emu/cm{sup 3}. Experimental and theoretical results suggested that the oxygen vacancies and the unique porous structure of the films are responsible for the large ferromagnetism. There are two modes of coupling between oxygen vacancies in the porous ZnO films: (i) exchange interactions directly between the oxygen vacancies and (ii) with the mediation of conduction electrons. In addition, it was found that the magnetic moment of ZnO films can be changed by tuning the concentration of oxygen vacancies. These observations may be useful in the development of ZnO-based spintronics devices.

  2. Saturated Switching Systems

    CERN Document Server

    Benzaouia, Abdellah

    2012-01-01

    Saturated Switching Systems treats the problem of actuator saturation, inherent in all dynamical systems by using two approaches: positive invariance in which the controller is designed to work within a region of non-saturating linear behaviour; and saturation technique which allows saturation but guarantees asymptotic stability. The results obtained are extended from the linear systems in which they were first developed to switching systems with uncertainties, 2D switching systems, switching systems with Markovian jumping and switching systems of the Takagi-Sugeno type. The text represents a thoroughly referenced distillation of results obtained in this field during the last decade. The selected tool for analysis and design of stabilizing controllers is based on multiple Lyapunov functions and linear matrix inequalities. All the results are illustrated with numerical examples and figures many of them being modelled using MATLAB®. Saturated Switching Systems will be of interest to academic researchers in con...

  3. Electric conductivity for laboratory and field monitoring of induced partial saturation (IPS) in sands

    Science.gov (United States)

    Kazemiroodsari, Hadi

    Liquefaction is loss of shear strength in fully saturated loose sands caused by build-up of excess pore water pressure, during moderate to large earthquakes, leading to catastrophic failures of structures. Currently used liquefaction mitigation measures are often costly and cannot be applied at sites with existing structures. An innovative, practical, and cost effective liquefaction mitigation technique titled "Induced Partial Saturation" (IPS) was developed by researchers at Northeastern University. The IPS technique is based on injection of sodium percarbonate solution into fully saturated liquefaction susceptible sand. Sodium percarbonate dissolves in water and breaks down into sodium and carbonate ions and hydrogen peroxide which generates oxygen gas bubbles. Oxygen gas bubbles become trapped in sand pores and therefore decrease the degree of saturation of the sand, increase the compressibility of the soil, thus reduce its potential for liquefaction. The implementation of IPS required the development and validation of a monitoring and evaluation technique that would help ensure that the sands are indeed partially saturated. This dissertation focuses on this aspect of the IPS research. The monitoring system developed was based on using electric conductivity fundamentals and probes to detect the transport of chemical solution, calculate degree of saturation of sand, and determine the final zone of partial saturation created by IPS. To understand the fundamentals of electric conductivity, laboratory bench-top tests were conducted using electric conductivity probes and small specimens of Ottawa sand. Bench-top tests were used to study rate of generation of gas bubbles due to reaction of sodium percarbonate solution in sand, and to confirm a theory based on which degree of saturation were calculated. In addition to bench-top tests, electric conductivity probes were used in a relatively large sand specimen prepared in a specially manufactured glass tank. IPS was

  4. Oxygen supply and oxidative phosphorylation limitation in rat myocardium in situ.

    Science.gov (United States)

    Kreutzer, U; Mekhamer, Y; Chung, Y; Jue, T

    2001-05-01

    The 1H-NMR signal of the proximal histidyl-N(delta)H of deoxymyoglobin is detectable in the in situ rat myocardium and can reflect the intracellular PO2. Under basal normoxic conditions, the cellular PO2 is sufficient to saturate myoglobin (Mb). No proximal histidyl signal of Mb is detectable. On ligation of the left anterior descending coronary artery, the Mb signal at 78 parts/million (ppm) appears, along with a peak shoulder assigned to the corresponding signal of Hb. During dopamine infusion up to 80 microg. kg(-1) x min(-1), both the heart rate-pressure product (RPP) and myocardial oxygen consumption (MVO2) increase by about a factor of 2. Coronary flow increases by 84%, and O2 extraction (arteriovenous O2 difference) rises by 31%. Despite the increased respiration and work, no deoxymyoglobin signal is detected, implying that the intracellular O2 level still saturates MbO2, well above the PO2 at 50% saturation of Mb. The phosphocreatine (PCr) level decreases, however, during dopamine stimulation, and the ratio of the change in P(i) over PCr (DeltaP(i)/PCr) increases by 0.19. Infusion of either pyruvate, as the primary substrate, or dichloroacetate, a pyruvate dehydrogenase activator, abolishes the change in DeltaP(i)/PCr. Intracellular O2 supply does not limit MVO2, and the role of ADP in regulating respiration in rat myocardium in vivo remains an open question.

  5. Soil aquifer treatment of artificial wastewater under saturated conditions

    KAUST Repository

    Essandoh, H. M K

    2011-05-01

    A 2000 mm long saturated laboratory soil column was used to simulate soil aquifer treatment under saturated conditions to assess the removal of chemical and biochemical oxygen demand (COD and BOD), dissolved organic carbon (DOC), nitrogen and phosphate, using high strength artificial wastewater. The removal rates were determined under a combination of constant hydraulic loading rates (HLR) and variable COD concentrations as well as variable HLR under a constant COD. Within the range of COD concentrations considered (42 mg L-1-135 mg L-1) it was found that at fixed hydraulic loading rate, a decrease in the influent concentrations of dissolved organic carbon (DOC), biochemical oxygen demand (BOD), total nitrogen and phosphate improved their removal efficiencies. At the high COD concentrations applied residence times influenced the redox conditions in the soil column. Long residence times were detrimental to the removal process for COD, BOD and DOC as anoxic processes and sulphate reduction played an important role as electron acceptors. It was found that total COD mass loading within the range of 911 mg d-1-1780 mg d-1 applied as low COD wastewater infiltrated coupled with short residence times would provide better effluent quality than the same mass applied as a COD with higher concentration at long residence times. The opposite was true for organic nitrogen where relatively high concentrations coupled with long residence time gave better removal efficiency. © 2011.

  6. Comparison the Effects of Shallow and Deep Endotracheal Tube Suctioning on Respiratory Rate, Arterial Blood Oxygen Saturation and Number of Suctioning in Patients Hospitalized in the Intensive Care Unit: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasinia

    2014-09-01

    Full Text Available Introduction: Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR, arterial blood oxygen saturation (SpO2 and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. Methods: In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA, chi-square and independent t-tests. Results: RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion: Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient’s trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  7. Comparison the effects of shallow and deep endotracheal tube suctioning on respiratory rate, arterial blood oxygen saturation and number of suctioning in patients hospitalized in the intensive care unit: a randomized controlled trial.

    Science.gov (United States)

    Abbasinia, Mohammad; Irajpour, Alireza; Babaii, Atye; Shamali, Mehdi; Vahdatnezhad, Jahanbakhsh

    2014-09-01

    Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR), arterial blood oxygen saturation (SpO2) and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA), chi-square and independent t-tests. RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion : Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  8. Physiological closed-loop control in intelligent oxygen therapy: A review.

    Science.gov (United States)

    Sanchez-Morillo, Daniel; Olaby, Osama; Fernandez-Granero, Miguel Angel; Leon-Jimenez, Antonio

    2017-07-01

    Oxygen therapy has become a standard care for the treatment of patients with chronic obstructive pulmonary disease and other hypoxemic chronic lung diseases. In current systems, manually continuous adjustment of O 2 flow rate is a time-consuming task, often unsuccessful, that requires experienced staff. The primary aim of this systematic review is to collate and report on the principles, algorithms and accuracy of autonomous physiological close-loop controlled oxygen devices as well to present recommendations for future research and studies in this area. A literature search was performed on medical database MEDLINE, engineering database IEEE-Xplore and wide-raging scientific databases Scopus and Web of Science. A narrative synthesis of the results was carried out. A summary of the findings of this review suggests that when compared to the conventional manual practice, the closed-loop controllers maintain higher saturation levels, spend less time below the target saturation, and save oxygen resources. Nonetheless, despite of their potential, autonomous oxygen therapy devices are scarce in real clinical applications. Robustness of control algorithms, fail-safe mechanisms, limited reliability of sensors, usability issues and the need for standardized evaluating methods of assessing risks can be among the reasons for this lack of matureness and need to be addressed before the wide spreading of a new generation of automatic oxygen devices. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Data on the effect of target temperature management at 32–34 °C in cardiac arrest patients considering assessment by regional cerebral oxygen saturation: A multicenter retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Yuka Nakatani

    2018-04-01

    Full Text Available This data article contains raw data and supplementary analyzed data regarding to the article entitled “Effect of target temperature management at 32–34 °C in cardiac arrest patients considering assessment by regional cerebral oxygen saturation: A multicenter retrospective cohort study”. We examined the effectiveness of target temperature management (TTM at 32–34 °C considering degrees of patients’ cerebral injury and cerebral circulation assessed by regional cerebral oxygen saturation (rSO2. The research is a secondary analysis of prospectively collected registry, in which comatose patients who were transferred to 15 hospitals in Japan after out-of-hospital cardiac arrest (OHCA, and we included 431 study patients. Propensity score analysis revealed that TTM at 32–34 °C decreased all-cause mortality in patients with rSO2 41–60%, and increased favorable neurological outcomes in patients with rSO2 41–60% in the original research article. With regard to the balance of covariates of propensity-score matching (PSM and inverse-probability weighting (IPW analyses, some covariates were not well balanced after the analyses between groups. The overlap plots indicate the overlap of densities of the propensity scores are low in group rSO2 41–60% and group rSO2 ≥ 61%. When patients were limited to those who achieved return of spontaneous circulation (ROSC until/on hospitals arrival, TTM still tended to decrease all-cause mortality and increase favorable outcomes in group rSO2 41–60%.

  10. Studies of non-isothermal flow in saturated and partially saturated porous media

    International Nuclear Information System (INIS)

    Ho, C.K.; Maki, K.S.; Glass, R.J.

    1993-01-01

    Physical and numerical experiments have been performed to investigate the behavior of nonisothermal flow in two-dimensional saturated and partially saturated porous media. The physical experiments were performed to identify non-isothermal flow fields and temperature distributions in fully saturated, half-saturated, and residually saturated two-dimensional porous media with bottom heating and top cooling. Two counter-rotating liquid-phase convective cells were observed to develop in the saturated regions of all three cases. Gas-phase convection was also evidenced in the unsaturated regions of the partially saturated experiments. TOUGH2 numerical simulations of the saturated case were found to be strongly dependent on the assumed boundary conditions of the physical system. Models including heat losses through the boundaries of the test cell produced temperature and flow fields that were in better agreement with the observed temperature and flow fields than models that assumed insulated boundary conditions. A sensitivity analysis also showed that a reduction of the bulk permeability of the porous media in the numerical simulations depressed the effects of convection, flattening the temperature profiles across the test cell

  11. Agreement between arterial partial pressure of carbon dioxide and saturation of hemoglobin with oxygen values obtained by direct arterial blood measurements versus noninvasive methods in conscious healthy and ill foals.

    Science.gov (United States)

    Wong, David M; Alcott, Cody J; Wang, Chong; Bornkamp, Jennifer L; Young, Jessica L; Sponseller, Brett A

    2011-11-15

    To determine agreement between indirect measurements of end-tidal partial pressure of carbon dioxide (PetCO(2)) and saturation of hemoglobin with oxygen as measured by pulse oximetry (SpO(2)) with direct measurements of PaCO(2) and calculated saturation of hemoglobin with oxygen in arterial blood (SaO(2)) in conscious healthy and ill foals. Validation study. 10 healthy and 21 ill neonatal foals. Arterial blood gas analysis was performed on healthy and ill foals examined at a veterinary teaching hospital to determine direct measurements of PaCO(2) and PaO(2) along with SaO(2). Concurrently, PetCO(2) was measured with a capnograph inserted into a naris, and SpO(2) was measured with a reflectance probe placed at the base of the tail. Paired values were compared by use of Pearson correlation coefficients, and level of agreement was assessed with the Bland-Altman method. Mean ± SD difference between PaCO(2) and PetCO(2) was 0.1 ± 5.0 mm Hg. There was significant strong correlation (r = 0.779) and good agreement between PaCO(2) and PetCO(2). Mean ± SD difference between SaO(2) and SpO(2) was 2.5 ± 3.5%. There was significant moderate correlation (r = 0.499) and acceptable agreement between SaO(2) and SpO(2). Both PetCO(2) obtained by use of nasal capnography and SpO(2) obtained with a reflectance probe are clinically applicable and accurate indirect methods of estimating and monitoring PaCO(2) and SaO(2) in neonatal foals. Indirect methods should not replace periodic direct measurement of corresponding parameters.

  12. Effects of carbon dioxide insufflation on regional cerebral oxygenation during laparoscopic surgery in children: a prospective study.

    Science.gov (United States)

    Tuna, Ayca Tas; Akkoyun, Ibrahim; Darcin, Sevtap; Palabiyik, Onur

    2016-01-01

    Laparoscopic surgery has become a popular surgical tool when compared to traditional open surgery. There are limited data on pediatric patients regarding whether pneumoperitoneum affects cerebral oxygenation although end-tidal CO2 concentration remains normal. Therefore, this study was designed to evaluate the changes of cerebral oxygen saturation using near-infrared spectroscope during laparoscopic surgery in children. The study comprised forty children who were scheduled for laparoscopic (Group L, n=20) or open (Group O, n=20) appendectomy. Hemodynamic variables, right and left regional cerebral oxygen saturation (RrSO2 and LrSO2), fraction of inspired oxygen, end-tidal carbon dioxide pressure (PETCO2), peak inspiratory pressure (Ppeak), respiratory minute volume, inspiratory and end-tidal concentrations of sevoflurane and body temperature were recorded. All parameters were recorded after anesthesia induction and before start of surgery (T0, baseline), 15min after start of surgery (T1), 30min after start of surgery (T2), 45min after start of surgery (T3), 60min after start of surgery (T4) and end of the surgery (T5). There were progressive decreases in both RrSO2 and LrSO2 levels in both groups, which were not statistically significant at T1, T2, T3, T4. The RrSO2 levels of Group L at T5 were significantly lower than that of Group O. One patient in Group L had an rSO2 value <80% of the baseline value. Carbon dioxide insufflation during pneumoperitoneum in pediatric patients may not affect cerebral oxygenation under laparoscopic surgery. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  13. [Effects of carbon dioxide insufflation on regional cerebral oxygenation during laparoscopic surgery in children: a prospective study].

    Science.gov (United States)

    Tuna, Ayca Tas; Akkoyun, Ibrahim; Darcin, Sevtap; Palabiyik, Onur

    2016-01-01

    Laparoscopic surgery has become a popular surgical tool when compared to traditional open surgery. There are limited data on pediatric patients regarding whether pneumoperitoneum affects cerebral oxygenation although end-tidal CO2 concentration remains normal. Therefore, this study was designed to evaluate the changes of cerebral oxygen saturation using near-infrared spectroscope during laparoscopic surgery in children. The study comprised forty children who were scheduled for laparoscopic (Group L, n=20) or open (Group O, n=20) appendectomy. Hemodynamic variables, right and left regional cerebral oxygen saturation (RrSO2 and LrSO2), fraction of inspired oxygen, end-tidal carbon dioxide pressure (PETCO2), peak inspiratory pressure (Ppeak), respiratory minute volume, inspiratory and end-tidal concentrations of sevoflurane and body temperature were recorded. All parameters were recorded after anesthesia induction and before start of surgery (T0, baseline), 15min after start of surgery (T1), 30min after start of surgery (T2), 45min after start of surgery (T3), 60min after start of surgery (T4) and end of the surgery (T5). There were progressive decreases in both RrSO2 and LrSO2 levels in both groups, which were not statistically significant at T1, T2, T3, T4. The RrSO2 levels of Group L at T5 were significantly lower than that of Group O. One patient in Group L had an rSO2 value <80% of the baseline value. Carbon dioxide insufflation during pneumoperitoneum in pediatric patients may not affect cerebral oxygenation under laparoscopic surgery. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  14. Oxygen sensitive polymeric nanocapsules for optical dissolved oxygen sensors

    Science.gov (United States)

    Sun, Zhijuan; Cai, Chenxin; Guo, Fei; Ye, Changhuai; Luo, Yingwu; Ye, Shuming; Luo, Jianchao; Zhu, Fan; Jiang, Chunyue

    2018-04-01

    Immobilization of the oxygen-sensitive probes (OSPs) in the host matrix greatly impacts the performance and long-term usage of the optical dissolved oxygen (DO) sensors. In this work, fluorescent dyes, as the OSPs, were encapsulated with a crosslinked fluorinated polymer shell by interfacial confined reversible addition fragmentation chain transfer miniemulsion polymerization to fabricate oxygen sensitive polymeric nanocapsules (NCs). The location of fluorescent dyes and the fluorescent properties of the NCs were fully characterized by fourier transform infrared spectrometer, x-ray photoelectron spectrometer and fluorescent spectrum. Dye-encapsulated capacity can be precisely tuned from 0 to 1.3 wt% without self-quenching of the fluorescent dye. The crosslinked fluorinated polymer shell is not only extremely high gas permeability, but also prevents the fluorescent dyes from leakage in aqueous as well as in various organic solvents, such as ethanol, acetone and tetrahydrofuran (THF). An optical DO sensor based on the oxygen sensitive NCs was fabricated, showing high sensitivity, short response time, full reversibility, and long-term operational stability of online monitoring DO. The sensitivity of the optical DO sensor is 7.02 (the ratio of the response value in fully deoxygenated and saturated oxygenated water) in the range 0.96-14.16 mg l-1 and the response time is about 14.3 s. The sensor’s work curve was fit well using the modified Stern-Volmer equation by two-site model, and its response values are hardly affected by pH ranging from 2 to 12 and keep constant during continuous measurement for 3 months. It is believed that the oxygen sensitive polymeric NCs-based optical DO sensor could be particularly useful in long-term online DO monitoring in both aqueous and organic solvent systems.

  15. Determination of optical properties, drug concentration, and tissue oxygenation in human pleural tissue before and after Photofrin-mediated photodynamic therapy

    Science.gov (United States)

    Ong, Yi Hong; Padawer-Curry, Jonah; Finlay, Jarod C.; Kim, Michele M.; Dimofte, Andreea; Cengel, Keith; Zhu, Timothy C.

    2018-02-01

    PDT efficacy depends on the concentration of photosensitizer, oxygen, and light delivery in patient tissues. In this study, we measure the in-vivo distribution of important dosimetric parameters, namely the tissue optical properties (absorption μa (λ) and scattering μs ' (λ) coefficients), photofrin concentration (cphotofrin), blood oxygen saturation (%StO2), and total hemoglobin concentration (THC), before and after PDT. We characterize the inter- and intra-patient heterogeneity of these quantities and explore how these properties change as a result of PDT treatment. The result suggests the need for real-time dosimetry during PDT to optimize the treatment condition depending on the optical and physiological properties.

  16. Interactive effects of oxygen, carbon dioxide and flow on photosynthesis and respiration in the scleractinian coral Galaxea fascicularis.

    Science.gov (United States)

    Osinga, Ronald; Derksen-Hooijberg, Marlous; Wijgerde, Tim; Verreth, Johan A J

    2017-06-15

    Rates of dark respiration and net photosynthesis were measured for six replicate clonal fragments of the stony coral Galaxea fascicularis (Linnaeus 1767), which were incubated under 12 different combinations of dissolved oxygen (20%, 100% and 150% saturation), dissolved carbon dioxide (9.5 and 19.1 µmol l -1 ) and water flow (1-1.6 versus 4-13 cm s -1 ) in a repeated measures design. Dark respiration was enhanced by increased flow and increased oxygen saturation in an interactive way, which relates to improved oxygen influx into the coral tissue. Oxygen saturation did not influence net photosynthesis: neither hypoxia nor hyperoxia affected net photosynthesis, irrespective of flow and pH, which suggests that hyperoxia does not induce high rates of photorespiration in this coral. Flow and pH had a synergistic effect on net photosynthesis: at high flow, a decrease in pH stimulated net photosynthesis by 14%. These results indicate that for this individual of G. fascicularis , increased uptake of carbon dioxide rather than increased efflux of oxygen explains the beneficial effect of water flow on photosynthesis. Rates of net photosynthesis measured in this study are among the highest ever recorded for scleractinian corals and confirm a strong scope for growth. © 2017. Published by The Company of Biologists Ltd.

  17. Saturated poroelastic actuators generated by topology optimization

    DEFF Research Database (Denmark)

    Andreasen, Casper Schousboe; Sigmund, Ole

    2011-01-01

    the coupling of internal fluid pressure and elastic shear stresses a slab of the optimized porous material deflects/deforms when a pressure is imposed and an actuator is created. Several phenomenologically based constraints are imposed in order to get a stable force transmitting actuator.......In this paper the fluid-structure interaction problem of a saturated porous media is considered. The pressure coupling properties of porous saturated materials change with the microstructure and this is utilized in the design of an actuator using a topology optimized porous material. By maximizing...

  18. Comparison of six-minute walking tests conducted with and without supplemental oxygen in patients with chronic obstructive pulmonary disease and exercise-induced oxygen desaturation

    International Nuclear Information System (INIS)

    Ozalevli, S.; Ozden, A.; Gocen, Z.; Cimrin, Arif Hikmet

    2007-01-01

    There are contradictory reports in the literature on the supplemental oxygen administered before or after exercise tests. In light of this, we compared the results of 6-minute walking tests performed in room-air conditions (A6MWT) in patients with supplemental oxygen (O6MWT) in patients with chronic obstructive pulmonary disease (COPD) and exercise-induced oxygen desaturation. Thirty-one patients with COPD were included in the study. The A6MWT and O6MWT were performed in randomized order on each patient. During the tests, severity dyspenia and tiring of the leg were evaluated by the Modified Borg Scale. Heart rate and pulsed oxygen saturation and blood pressure were measured by pulse oximeter. Walking distance was longer with the O6MWT than with the A6MWT (P=0.001). The O6MWT resulted in a smaller increase in dyspnea, leg fatigue and heart rate and a smaller drop in pulsed saturation than the A6MWT (P<0.05). The walking distance with O6MWT correlated with respiratory function and hemodynamic parameters (P<0.05). The O6MWT, which produced less hemodynamic stress and was safer than the A6MWT, might provide more accurate information on exercise limitations for patients with COPD. These results suggest that the O6MWT can be used as a standard walking exercise test for patients with COPd and exercise-induced oxygen desaturation. (author)

  19. Milrinone, a phosphodiesterase III inhibitor, prevents reduction of jugular bulb saturation during rewarming from hypothermic cardiopulmonary bypass.

    Science.gov (United States)

    Iritakenishi, T; Hayashi, Y; Yamanaka, H; Kamibayashi, T; Ueda, K; Mashimo, T

    2012-01-01

    Inadequate cerebral oxygen balance during cardiopulmonary bypass may cause neuropsychological dysfunction. Milrinone, a phosphodiesterase III inhibitor, augments cerebral blood flow by direct vasodilatation. We conducted a prospective, randomized study in patients undergoing cardiac surgery with cardiopulmonary bypass to clarify the clinical efficacy of milrinone in the imbalance of cerebral oxygen supply and demand during the rewarming period of cardiopulmonary bypass. This is a prospective, randomized and placebo-controlled study. After anesthesia, a 5.5 F fiberoptic oximeter catheter was inserted into the right jugular bulb retrogradely for monitoring the jugular venous oxyhemoglobin saturation (SjO(2)). Patients were randomly assigned to two groups, one receiving a continuous infusion of milrinone, 0.5 µg/kg/min during hypothermic cardiopulmonary bypass, and the other receiving saline as control. Milrinone significantly prevented the reduction of the jugular venous oxyhemoglobin saturation at 10 minutes from the start of rewarming compared with the control group, but did not do so from 10 to 20 minutes after rewarming. Milrinone suppresses the reduction of SjO(2) and improves the balance of cerebral oxygen supply and demand during the early rewarming period of hypothermic cardiopulmonary bypass.

  20. Will open ocean oxygen stress intensify under climate change?

    OpenAIRE

    A. Gnanadesikan; J. P. Dunne; J. John

    2011-01-01

    Global warming is expected to reduce oxygen solubility and vertical exchange in the ocean, changes which would be expected to result in an increase in the volume of hypoxic waters. A simulation made with a full earth system model with dynamical atmosphere, ocean, sea ice and biogeochemical cycling shows that this holds true if the condition for hypoxia is set relatively high. However, the volume of the most hypoxic waters does not increase under global warming, as these waters actually become...

  1. Oxygen effect on the electrical characteristics of pentacene transistors

    International Nuclear Information System (INIS)

    Hu Yan; Dong Guifang; Hu Yuanchuan; Wang Liduo; Qiu Yong

    2006-01-01

    The effect of oxygen on the electrical characteristics of organic thin film transistors with pentacene as the active layer has been investigated. The saturation currents and mobilities of the transistors increase as the ambient oxygen concentration decreases, which is ascribed to the formation of a charge transfer complex between pentacene and O 2 . The deposition rate of the pentacene layer affects this phenomenon. The transistor with the pentacene layer deposited at a rate of 15 nm min -1 shows higher sensitivity to oxygen concentration than the device with the pentacene layer deposited at 30 nm min -1 . We suggest that when deposited at a lower rate the pentacene film is less compact, leading to easier entrance of oxygen into the charge accumulation region

  2. Bulk elastic wave propagation in partially saturated porous solids

    International Nuclear Information System (INIS)

    Berryman, J.G.; Thigpen, L.; Chin, R.C.Y.

    1988-01-01

    The linear equations of motion that describe the behavior of small disturbances in a porous solid containing both liquid and gas are solved for bulk wave propagation. The equations have been simplified by neglecting effects due to changes in capillary pressure. With this simplifying assumption, the equations reduce to two coupled (vector) equations of the form found in Biot's equations (for full saturation) but with more complicated coefficients. As in fully saturated solids, two shear waves with the same speed but different polarizations exist as do two compressional waves with distinct speeds. Attenuation effects can be enhanced in the partially saturated solid, depending on the distribution of gas in the pore space. Two models of the liquid/gas spatial distribution are considered: a segregated-fluids model and a mixed-fluids model. The two models predict comparable attentuation when the gas saturation is low, but the segregated-fluids model predicts a more rapid roll-off of attenuation as the gas saturation increases

  3. Laser Doppler imaging, thermographic imaging, and tissue oxygen saturation measurements detect early skin reactions during breast radiotherapy

    Science.gov (United States)

    Harrison, David K.; Harrison, Eileen M.; Newton, David J.; Windsor, Phyllis M.

    2001-05-01

    A range of acute skin reactions, ranging from mild erythema to moist desquamation, can be seen in patients receiving standard fractionated radiotherapy to the breast for conservation therapy of breast carcinoma. In a number of cases these reactions can cause considerable discomfort and seriously affect the patient's quality of life. In previous studies we have used the techniques of laser Doppler imaging, digital thermographic imaging and lightguide spectrophotometry to study oxygen supply and blood flow in inflammatory reactions induced experimentally in forearm skin. The present study is an attempt to use the same techniques to investigate whether any or all of them can detect changes in breast skin very early on in the course of radiotherapy treatment. A further aim of the longer term study is to investigate to what extent these early changes may be able to predict the occurrence later of severe acute or delayed reactions.

  4. Comparison of actual oxygen delivery kinetics to those predicted by mathematical modeling following stage 1 palliation just prior to superior cavopulmonary anastomosis.

    Science.gov (United States)

    Yuki, Koichi; DiNardo, James A

    2015-02-01

    Optimizing systemic oxygen delivery (DO2) and hemodynamics in children with hypoplastic left heart syndrome (HLHS) is a clinical challenge. Mathematical modeling of the HLHS circulation has been used to determine the relationship between oxygen kinetic parameters and DO2 and to determine how DO2 might be optimized. The model demonstrates that neither arterial oxygen saturation (SaO2) nor mixed venous oxygen saturation (SvO2) alone accurately predicts DO2. Oxygen delivery kinetics predicted by previously described mathematical modeling were compared with actual patients' hemodynamic data. We sought to determine which patient derived parameters correlated best with DO2. Patients with HLHS who underwent cardiac catheterization prior to surgery to create a superior cavopulmonary anastomosis from 2007 to 2011 were identified. Hemodynamic data obtained were compared with the data derived from the mathematical model. Correlations between SaO2, SvO2, SaO2-SvO2, SaO2/(SaO2-SvO2), pulmonary-to-systemic blood flow ratio (Qp/Qs), and DO2 were evaluated using both linear and nonlinear analyses, and R(2) was calculated. Patients' data fit most aspects of the mathematical model. DO2 had the best correlation with SaO2/(SaO2-SvO2; R(2) = 0.8755) followed by SaO2 -SvO2 (R(2) = 0.8063), while SaO2 or SvO2 alone did not demonstrate a significant correlation as predicated by the mathematical model (R(2) = 0.09564 and 0.4831, respectively). SaO2/(SaO2 -SvO2) would be useful clinically to track changes in DO2 that occur with changes in patient condition or with interventions. © 2014 John Wiley & Sons Ltd.

  5. Pressure and fluid saturation prediction in a multicomponent reservoir, using combined seismic and electromagnetic imaging

    International Nuclear Information System (INIS)

    Hoversten, G.M.; Gritto, Roland; Washbourne, John; Daley, Tom

    2002-01-01

    This paper presents a method for combining seismic and electromagnetic measurements to predict changes in water saturation, pressure, and CO 2 gas/oil ratio in a reservoir undergoing CO 2 flood. Crosswell seismic and electromagnetic data sets taken before and during CO 2 flooding of an oil reservoir are inverted to produce crosswell images of the change in compressional velocity, shear velocity, and electrical conductivity during a CO 2 injection pilot study. A rock properties model is developed using measured log porosity, fluid saturations, pressure, temperature, bulk density, sonic velocity, and electrical conductivity. The parameters of the rock properties model are found by an L1-norm simplex minimization of predicted and observed differences in compressional velocity and density. A separate minimization, using Archie's law, provides parameters for modeling the relations between water saturation, porosity, and the electrical conductivity. The rock-properties model is used to generate relationships between changes in geophysical parameters and changes in reservoir parameters. Electrical conductivity changes are directly mapped to changes in water saturation; estimated changes in water saturation are used along with the observed changes in shear wave velocity to predict changes in reservoir pressure. The estimation of the spatial extent and amount of CO 2 relies on first removing the effects of the water saturation and pressure changes from the observed compressional velocity changes, producing a residual compressional velocity change. This velocity change is then interpreted in terms of increases in the CO 2 /oil ratio. Resulting images of the CO 2 /oil ratio show CO 2 -rich zones that are well correlated to the location of injection perforations, with the size of these zones also correlating to the amount of injected CO 2 . The images produced by this process are better correlated to the location and amount of injected CO 2 than are any of the individual

  6. Marine species in ambient low-oxygen regions subject to double jeopardy impacts of climate change.

    Science.gov (United States)

    Stortini, Christine H; Chabot, Denis; Shackell, Nancy L

    2017-06-01

    We have learned much about the impacts of warming on the productivity and distribution of marine organisms, but less about the impact of warming combined with other environmental stressors, including oxygen depletion. Also, the combined impact of multiple environmental stressors requires evaluation at the scales most relevant to resource managers. We use the Gulf of St. Lawrence, Canada, characterized by a large permanently hypoxic zone, as a case study. Species distribution models were used to predict the impact of multiple scenarios of warming and oxygen depletion on the local density of three commercially and ecologically important species. Substantial changes are projected within 20-40 years. A eurythermal depleted species already limited to shallow, oxygen-rich refuge habitat (Atlantic cod) may be relatively uninfluenced by oxygen depletion but increase in density within refuge areas with warming. A more stenothermal, deep-dwelling species (Greenland halibut) is projected to lose ~55% of its high-density areas under the combined impacts of warming and oxygen depletion. Another deep-dwelling, more eurythermal species (Northern shrimp) would lose ~4% of its high-density areas due to oxygen depletion alone, but these impacts may be buffered by warming, which may increase density by 8% in less hypoxic areas, but decrease density by ~20% in the warmest parts of the region. Due to local climate variability and extreme events, and that our models cannot project changes in species sensitivity to hypoxia with warming, our results should be considered conservative. We present an approach to effectively evaluate the individual and cumulative impacts of multiple environmental stressors on a species-by-species basis at the scales most relevant to managers. Our study may provide a basis for work in other low-oxygen regions and should contribute to a growing literature base in climate science, which will continue to be of support for resource managers as climate change

  7. Law of nonlinear flow in saturated clays and radial consolidation

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    It was derived that micro-scale amount level of average pore radius of clay changed from 0.01 to 0.1 micron by an equivalent concept of flow in porous media. There is good agreement between the derived results and test ones. Results of experiments show that flow in micro-scale pore of saturated clays follows law of nonlinear flow. Theoretical analyses demonstrate that an interaction of solid-liquid interfaces varies inversely with permeability or porous radius. The interaction is an important reason why nonlinear flow in saturated clays occurs. An exact mathematical model was presented for nonlinear flow in micro-scale pore of saturated clays. Dimension and physical meanings of parameters of it are definite. A new law of nonlinear flow in saturated clays was established. It can describe characteristics of flow curve of the whole process of the nonlinear flow from low hydraulic gradient to high one. Darcy law is a special case of the new law. A mathematical model was presented for consolidation of nonlinear flow in radius direction in saturated clays with constant rate based on the new law of nonlinear flow. Equations of average mass conservation and moving boundary, and formula of excess pore pressure distribution and average degree of consolidation for nonlinear flow in saturated clay were derived by using an idea of viscous boundary layer, a method of steady state in stead of transient state and a method of integral of an equation. Laws of excess pore pressure distribution and changes of average degree of consolidation with time were obtained. Results show that velocity of moving boundary decreases because of the nonlinear flow in saturated clay. The results can provide geology engineering and geotechnical engineering of saturated clay with new scientific bases. Calculations of average degree of consolidation of the Darcy flow are a special case of that of the nonlinear flow.

  8. Shear weakening for different lithologies observed at different saturation stages

    Science.gov (United States)

    Diethart-Jauk, Elisabeth; Gegenhuber, Nina

    2018-01-01

    For this study, samples from different lithologies ("Leitha"-limestone, "Dachstein"-limestone, "Haupt"-dolomite, "Bunt"-sandstone, Grey Berea sandstone, granite, quartzite and basalt) were selected. Samples were dried at 70 °C, respectively 105 °C and were saturated with brine. Mass, porosity, permeability, compressional and shear wave velocity were determined from dry and brine saturated samples at laboratory conditions, based on an individual measurement program. Shear modulus was calculated to find out, if shear weakening exists for the dataset. Shear weakening means that shear modulus of dry samples is higher than of saturated samples, but it is assumed that shear modulus is unaffected by saturation. "Dachstein"-limestone and basalt show shear weakening, quartzite samples show both weakening and hardening. Granite samples are affected by temperature, after drying with 105 °C no change can be observed anymore. "Bunt"-sandstone samples show a change in the shear modulus in a small extent, although they may contain clay minerals. The other lithologies show no effect. Explanations for carbonate samples can be the complicated pore structure, for basalt it could be that weathering creates clay minerals which are known as causes for a change of the shear modulus. Fluid viscosity can also be an important factor.

  9. Monitoring Cerebral and Renal Oxygenation Status during Neonatal Digestive Surgeries Using Near Infrared Spectroscopy

    Directory of Open Access Journals (Sweden)

    Jonathan Beck

    2017-06-01

    Full Text Available BackgroundDepending on the initial pathology, hypovolemia, intra-abdominal hypertension, and sepsis are often encountered in neonatal digestive surgery. Accurate newborn monitoring during and after surgery is essential to adapt resuscitation protocols. Near infrared spectroscopy (NIRS is non-invasive and can detect hypoperfusion which indicates a low circulatory blood flow, regardless of the cause.ObjectiveEvaluating changes in cerebral and renal regional oxygen saturation during neonatal digestive surgeries, conducted according to normal practices, with commonly used monitoring parameters. Analyzing retrospectively the inter-relationships between NIRS values and mean arterial pressure (MAP values as well as pre-ductal SpO2.MethodsProspective, descriptive, monocentric study. All neonates referred for surgery were included. NIRS allows the measurement of cerebral and renal oxygenation fluctuations, as well as calculating difference in intraoperative and postoperative values.ResultsNineteen patients were included. Cerebral regional oxygen saturation (C rSO2 values were stable while renal regional oxygen saturation (R rSO2 values tended to decrease with time during surgery. Indeed, 72% of rSO2 decline episodes occurred after the first 30 min of surgery, without any significant statistical differences for the next 90 min of surgery. After surgery, the lowest average C and R rSO2 values were evidenced during the first 6 h, with 60% of C rSO2 and R rSO2 anomalies occurring in that time frame. There was no significant statistical difference observed in the following 18 h. There was a significant correlation between R rSO2 and SpO2 values (p < 0.01, but not with C rSO2 values. There was no correlation with the MAP either for the C rSO2 values or R rSO2 ones.ConclusionNIRS is a promising non-invasive bedside tool to monitor cerebral and tissue perfusion, analyzing tissue microcirculation. NIRS has its interest to guide neonatal digestive

  10. Relationship Between Cerebral Oxygenation and Hemodynamic and Oxygen Transport Parameters in Surgery for Acquired Heart Diseases

    Directory of Open Access Journals (Sweden)

    A. I. Lenkin

    2012-01-01

    Full Text Available Objective: to evaluate the relationship between cerebral oxygenation and hemodynamic and oxygen transport parameters in surgical correction of concomitant acquired heart diseases. Subjects and methods. Informed consent was received from 40 patients who required surgery because of concomitant (two or more acquired heart defects. During procedure, perioperative monitoring of oxygen transport and cerebral oxygenation was performed with the aid of PiCCO2 monitor (Pulsion Medical Systems, Germany and a Fore-Sight cerebral oximeter (CASMED, USA. Anesthesia was maintained with propofol and fen-tanyl, by monitoring the depth of anesthesia. Early postoperative intensive therapy was based on the protocol for early targeted correction of hemodynamic disorders. Oxygen transport and cerebral oxygenation parameters were estimated intraopera-tively and within 24 postoperative hours. A statistical analysis including evaluation of Spearman correlations was performed with the aid of SPSS 15.0. Results. During perfusion, there was a relationship between cerebral oximetry values and hemat-ocrit levels, and oxygen partial pressure in the venous blood. Furthermore, a negative correlation between cerebral oximetry values and blood lactate levels was found 30 minutes after initiation of extracorporeal circulation (EC. During the study, there was a positive correlation between cerebral oxygenation and values of cardiac index, central venous saturation, and oxygen delivery index. There was a negative relationship between cerebral oxygenation and extravascular lung water at the beginning of surgery and a correlation between cerebral oximetry values and oxygenation index by the end of the first 24 postoperative hours. Conclusion. The cerebral oxygenation values correlate -with the main determinants of oxygen transport during EC and after cardiac surgical procedures. Cerebral oximetry may be used in early targeted therapy for the surgical correction of acquired combined

  11. Microscopic analysis of saturable absorbers: Semiconductor saturable absorber mirrors versus graphene

    Energy Technology Data Exchange (ETDEWEB)

    Hader, J.; Moloney, J. V. [Nonlinear Control Strategies, Inc., 3542 N. Geronimo Ave., Tucson, Arizona 85705 (United States); College of Optical Sciences, University of Arizona, Tucson, Arizona 85721 (United States); Yang, H.-J.; Scheller, M. [College of Optical Sciences, University of Arizona, Tucson, Arizona 85721 (United States); Koch, S. W. [Department of Physics and Materials Sciences Center, Philipps Universität Marburg, Renthof 5, 35032 Marburg (Germany)

    2016-02-07

    Fully microscopic many-body calculations are used to study the influence of strong sub-picosecond pulses on the carrier distributions and corresponding optical response in saturable absorbers used for mode-locking—semiconductor (quantum well) saturable absorber mirrors (SESAMs) and single layer graphene based saturable absorber mirrors (GSAMs). Unlike in GSAMs, the saturation fluence and recovery time in SESAMs show a strong spectral dependence. While the saturation fluence in the SESAM is minimal at the excitonic bandgap, the optimal recovery time and least pulse distortion due to group delay dispersion are found for excitation higher in the first subband. For excitation near the SESAM bandgap, the saturation fluence is about one tenth of that in the GSAM. At energies above the bandgap, the fluences in both systems become similar. A strong dependence of the saturation fluence on the pulse width in both systems is caused by carrier relaxation during the pulse. The recovery time in graphene is found to be about two to four times faster than that in the SESAMs. The occurrence of negative differential transmission in graphene is shown to be caused by dopant related carriers. In SESAMs, a negative differential transmission is found when exciting below the excitonic resonance where excitation induced dephasing leads to an enhancement of the absorption. Comparisons of the simulation data to the experiment show a very good quantitative agreement.

  12. Measurement of forearm oxygen consumption

    DEFF Research Database (Denmark)

    Astrup, A; Simonsen, L; Bülow, J

    1988-01-01

    The classical forearm technique widely used for studies of skeletal muscle metabolism requires arterial cannulation. To avoid arterial puncture it is becoming more common to arterialize blood from a contralateral hand vein by local heating. This modification and the classical method have produced...... blood flow and decreases skeletal muscle blood flow. This facilitates mixing of superficial blood with deep venous blood. Contralateral heating increased deep venous oxygen saturation and abolished the pronounced glucose-induced increase in oxygen consumption observed in the control experiments after...... contradictory results regarding the contribution of skeletal muscle to glucose-induced thermogenesis. The effect on forearm circulation and the metabolism of heating the contralateral hand was examined before and after an oral glucose load. The results suggest that contralateral heating increases subcutaneous...

  13. Do dental procedures affect lung function and arterial oxygen saturation in asthmatic patients?

    Directory of Open Access Journals (Sweden)

    Magdy Mahmoud Emara

    2013-04-01

    Conclusion: Asthmatic patients may be at a higher risk of developing oxygen desaturation after dental procedures regardless of their type with and without local anesthesia and a decrease in PEF after dental procedures with local anesthesia.

  14. Uptake rate of cationic mitochondrial inhibitor MKT-077 determines cellular oxygen consumption change in carcinoma cells.

    Directory of Open Access Journals (Sweden)

    John L Chunta

    Full Text Available OBJECTIVE: Since tumor radiation response is oxygen-dependent, radiosensitivity can be enhanced by increasing tumor oxygenation. Theoretically, inhibiting cellular oxygen consumption is the most efficient way to increase oxygen levels. The cationic, rhodacyanine dye-analog MKT-077 inhibits mitochondrial respiration and could be an effective metabolic inhibitor. However, the relationship between cellular MKT-077 uptake and metabolic inhibition is unknown. We hypothesized that rat and human mammary carcinoma cells would take up MKT-077, causing a decrease in oxygen metabolism related to drug uptake. METHODS: R3230Ac rat breast adenocarcinoma cells were exposed to MKT-077. Cellular MKT-077 concentration was quantified using spectroscopy, and oxygen consumption was measured using polarographic electrodes. MKT-077 uptake kinetics were modeled by accounting for uptake due to both the concentration and potential gradients across the plasma and mitochondrial membranes. These kinetic parameters were used to model the relationship between MKT-077 uptake and metabolic inhibition. MKT-077-induced changes in oxygen consumption were also characterized in MDA-MB231 human breast carcinoma cells. RESULTS: Cells took up MKT-077 with a time constant of ∼1 hr, and modeling showed that over 90% of intracellular MKT-077 was bound or sequestered, likely by the mitochondria. The uptake resulted in a rapid decrease in oxygen consumption, with a time constant of ∼30 minutes. Surprisingly the change in oxygen consumption was proportional to uptake rate, not cellular concentration. MKT-077 proved a potent metabolic inhibitor, with dose-dependent decreases of 45-73% (p = 0.003. CONCLUSIONS: MKT-077 caused an uptake rate-dependent decrease in cellular metabolism, suggesting potential efficacy for increasing tumor oxygen levels and radiosensitivity in vivo.

  15. Definition, significance and measurement of quantities pertaining to the oxygen carrying properties of human blood

    NARCIS (Netherlands)

    Zijlstra, WG; Maas, AHJ; Moran, RF

    1996-01-01

    A consistent set of definitions is given of the principal quantities pertaining to the oxygen transport by the blood, and of their mutual relationships, in relation to the methods used in their measurement. At the core is the correct definition of oxygen saturation, the deviation of which has

  16. Simulated effects of nitrogen saturation the global carbon budget using the IBIS model

    Science.gov (United States)

    Lu, Xuehe; Jiang, Hong; Liu, Jinxun; Zhang, Xiuying; Jin, Jiaxin; Zhu, Qiuan; Zhang, Zhen; Peng, Changhui

    2016-01-01

    Over the past 100 years, human activity has greatly changed the rate of atmospheric N (nitrogen) deposition in terrestrial ecosystems, resulting in N saturation in some regions of the world. The contribution of N saturation to the global carbon budget remains uncertain due to the complicated nature of C-N (carbon-nitrogen) interactions and diverse geography. Although N deposition is included in most terrestrial ecosystem models, the effect of N saturation is frequently overlooked. In this study, the IBIS (Integrated BIosphere Simulator) was used to simulate the global-scale effects of N saturation during the period 1961–2009. The results of this model indicate that N saturation reduced global NPP (Net Primary Productivity) and NEP (Net Ecosystem Productivity) by 0.26 and 0.03 Pg C yr−1, respectively. The negative effects of N saturation on carbon sequestration occurred primarily in temperate forests and grasslands. In response to elevated CO2 levels, global N turnover slowed due to increased biomass growth, resulting in a decline in soil mineral N. These changes in N cycling reduced the impact of N saturation on the global carbon budget. However, elevated N deposition in certain regions may further alter N saturation and C-N coupling.

  17. The adsorption of NO on an oxygen pre-covered Pt(1 1 1) surface: in situ high-resolution XPS combined with molecular beam studies

    Science.gov (United States)

    Zhu, J. F.; Kinne, M.; Fuhrmann, T.; Tränkenschuh, B.; Denecke, R.; Steinrück, H.-P.

    2003-12-01

    Adsorption of NO on a Pt(1 1 1) surface pre-covered with a p(2 × 2) atomic oxygen layer has been studied in situ by high-resolution X-ray photoelectron spectroscopy and temperature-programmed XPS using third-generation synchrotron radiation at BESSY II, Berlin, combined with molecular beam techniques and ex situ by low energy electron diffraction and temperature-programmed desorption. O 1s XP spectra reveal that an ordered p(2 × 2)-O layer dramatically changes the adsorption behavior of NO as compared to the clean surface. The atomic oxygen occupies fcc hollow sites, and therefore blocks NO adsorption on these sites, which are energetically preferred on clean Pt(1 1 1). As a consequence, NO populates on-top sites at low coverage. At 110 K for higher coverages, NO can additionally adsorb on hcp hollow sites, thereby inducing a shift of the O 1s binding energy of atomic oxygen towards lower energies by about 0.25 eV. The bond strength of the hcp hollow NO species to the substrate is weakened by the presence of atomic oxygen. A sharp p(2 × 2) LEED pattern is observed for NO adsorption on the oxygen pre-covered surface, up to saturation coverage. The total saturation coverage of NO on Pt(1 1 1) pre-covered with varying amounts of oxygen (below 0.25 ML) decreases linearly with the coverage of oxygen. The initial sticking coefficient of NO is reduced from 0.96 on clean Pt(1 1 1) to 0.88 on a p(2 × 2) oxygen pre-covered surface.

  18. Oxygen supply in aquatic ectotherms: partial pressure and solubility together explain biodiversity and size patterns.

    Science.gov (United States)

    Verberk, Wilco C E P; Bilton, David T; Calosi, Piero; Spicer, John I

    2011-08-01

    Aquatic ectotherms face the continuous challenge of capturing sufficient oxygen from their environment as the diffusion rate of oxygen in water is 3 x 10(5) times lower than in air. Despite the recognized importance of oxygen in shaping aquatic communities, consensus on what drives environmental oxygen availability is lacking. Physiologists emphasize oxygen partial pressure, while ecologists emphasize oxygen solubility, traditionally expressing oxygen in terms of concentrations. To resolve the question of whether partial pressure or solubility limits oxygen supply in nature, we return to first principles and derive an index of oxygen supply from Fick's classic first law of diffusion. This oxygen supply index (OSI) incorporates both partial pressure and solubility. Our OSI successfully explains published patterns in body size and species across environmental clines linked to differences in oxygen partial pressure (altitude, organic pollution) or oxygen solubility (temperature and salinity). Moreover, the OSI was more accurately and consistently related to these ecological patterns than other measures of oxygen (oxygen saturation, dissolved oxygen concentration, biochemical oxygen demand concentrations) and similarly outperformed temperature and altitude, which covaried with these environmental clines. Intriguingly, by incorporating gas diffusion rates, it becomes clear that actually more oxygen is available to an organism in warmer habitats where lower oxygen concentrations would suggest the reverse. Under our model, the observed reductions in aerobic performance in warmer habitats do not arise from lower oxygen concentrations, but instead through organismal oxygen demand exceeding supply. This reappraisal of how organismal thermal physiology and oxygen demands together shape aerobic performance in aquatic ectotherms and the new insight of how these components change with temperature have broad implications for predicting the responses of aquatic communities to

  19. Preparation of Boron Nitride Nanoparticles with Oxygen Doping and a Study of Their Room-Temperature Ferromagnetism.

    Science.gov (United States)

    Lu, Qing; Zhao, Qi; Yang, Tianye; Zhai, Chengbo; Wang, Dongxue; Zhang, Mingzhe

    2018-04-18

    In this work, oxygen-doped boron nitride nanoparticles with room-temperature ferromagnetism have been synthesized by a new, facile, and efficient method. There are no metal magnetic impurities in the nanoparticles analyzed by X-ray photoelectron spectroscopy. The boron nitride nanoparticles exhibit a parabolic shape with increase in the reaction time. The saturation magnetization value reaches a maximum of 0.2975 emu g -1 at 300 K when the reaction time is 12 h, indicating that the Curie temperature ( T C ) is higher than 300 K. Combined with first-principles calculation, the coupling between B 2p orbital, N 2p orbital, and O 2p orbital in the conduction bands is the main origin of room-temperature ferromagnetism and also proves that the magnetic moment changes according the oxygen-doping content change. Compared with other room temperature ferromagnetic semiconductors, boron nitride nanoparticles have widely potential applications in spintronic devices because of high temperature oxidation resistance and excellent chemical stability.

  20. The effect of rock electrical parameters on the calculation of reservoir saturation

    International Nuclear Information System (INIS)

    Li, Xiongyan; Qin, Ruibao; Liu, Chuncheng; Mao, Zhiqiang

    2013-01-01

    The error in calculating a reservoir saturation caused by the error in the cementation exponent, m, and the saturation exponent, n, should be analysed. In addition, the influence of m and n on the reservoir saturation should be discussed. Based on the Archie formula, the effect of variables m and n on the reservoir saturation is analysed, while the formula for the error in calculating the reservoir saturation, caused by the error in m and n, is deduced, and the main factors affecting the error in reservoir saturation are illustrated. According to the physical meaning of m and n, it can be interpreted that they are two independent parameters, i.e., there is no connection between m and n. When m and n have the same error, the impact of the variables on the calculation of the reservoir saturation should be compared. Therefore, when the errors of m and n are respectively equal to 0.2, 0.4 and 0.6, the distribution range of the errors in calculating the reservoir saturation is analysed. However, in most cases, the error of m and n is about 0.2. When the error of m is 0.2, the error in calculating the reservoir saturation ranges from 0% to 35%. Meanwhile, when the error in n is 0.2, the error in calculating the reservoir saturation is almost always below 5%. On the basis of loose sandstone, medium sandstone, tight sandstone, conglomerate, tuff, breccia, basalt, andesite, dacite and rhyolite, this paper first analyses the distribution range and change amplitude of m and n. Second, the impact of m and n on the calculation of reservoir saturation is elaborated upon. With regard to each lithology, the distribution range and change amplitude of m are greater than those of n. Therefore, compared with n, the effect of m on the reservoir saturation is stronger. The influence of m and n on the reservoir saturation is determined, and the error in calculating the reservoir saturation caused by the error of m and n is calculated. This is theoretically and practically significant for

  1. Canary in the coal mine: Historical oxygen decline in the Gulf of St. Lawrence due to large scale climate changes

    Science.gov (United States)

    Claret, M.; Galbraith, E. D.; Palter, J. B.; Gilbert, D.; Bianchi, D.; Dunne, J. P.

    2016-02-01

    The regional signature of anthropogenic climate change on the atmosphere and upper ocean is often difficult to discern from observational timeseries, dominated as they are by decadal climate variability. Here we argue that a long-term decline of dissolved oxygen concentrations observed in the Gulf of S. Lawrence (GoSL) is consistent with anthropogenic climate change. Oxygen concentrations in the GoSL have declined markedly since 1930 due primarily to an increase of oxygen-poor North Atlantic Central Waters relative to Labrador Current Waters (Gilbert et al. 2005). We compare these observations to a climate warming simulation using a very high-resolution global coupled ocean-atmospheric climate model. The numerical model (CM2.6), developed by the Geophysical Fluid Dynamics Laboratory, is strongly eddying and includes a biogeochemical module with dissolved oxygen. The warming scenario shows that oxygen in the GoSL decreases and it is associated to changes in western boundary currents and wind patterns in the North Atlantic. We speculate that the large-scale changes behind the simulated decrease in GoSL oxygen have also been at play in the real world over the past century, although they are difficult to resolve in noisy atmospheric data.

  2. Meal-induced changes in splanchnic blood flow and oxygen uptake in middle-aged healthy humans

    DEFF Research Database (Denmark)

    Madsen, Jan Lysgård; Søndergaard, SB; Møller, Søren

    2006-01-01

    OBJECTIVE: For decades, the determination of changes in splanchnic blood flow and oxygen uptake after a meal has been used in the management of patients with suspected chronic intestinal ischaemia. However, little is known about the normal meal-induced responses. The aim of the present study...... was therefore to measure the splanchnic blood flow and oxygen uptake before and after a standardized meal in a group of middle-aged normal volunteers. MATERIAL AND METHODS: Splanchnic blood flow and oxygen uptake were determined at baseline and after a 3600-kJ mixed meal in 8 healthy women (50-70 years) and 10...... healthy men (52-76 years). Splanchnic blood flow was measured during hepatic vein catheterization by indirect Fick principle with indocyanine green as the indicator. Splanchnic oxygen uptake was calculated from splanchnic blood flow and the arteriovenous oxygen difference. RESULTS: The meal induced...

  3. Oxygen Effects in Anaerobic Digestion

    Directory of Open Access Journals (Sweden)

    Deshai Botheju

    2009-10-01

    Full Text Available Interaction of free oxygen in bio-gasification is a sparsely studied area, apart from the common argument of oxygen being toxic and inhibitory for anaerobic micro-cultures. Some studies have, however, revealed increased solubilisation of organic matter in the presence of some free oxygen in anaerobic digestion. This article analyses these counterbalancing phenomena with a mathematical modelling approach using the widely accepted biochemical model ADM 1. Aerobic oxidation of soluble carbon and inhibition of obligatory anaerobic organisms are modelled using standard saturation type kinetics. Biomass dependent first order hydrolysis kinetics is used to relate the increased hydrolysis rate with oxygen induced increase in biomass growth. The amended model, ADM 1-Ox (oxygen, has 25 state variables and 22 biochemical processes, presented in matrix form. The computer aided simulation tool AQUASIM 2.1 is used to simulate the developed model. Simulation predictions are evaluated against experimental data obtained using a laboratory batch test array comprising miniature anaerobic bio-reactors of 100 ml total volume each, operated under different initial air headspaces giving rise to the different oxygen loading conditions. The reactors were initially fed with a glucose solution and incubated at 35 Celsius, for 563 hours. Under the oxygen load conditions of 22, 44 and 88 mg/L, the ADM1-Ox model simulations predicted the experimental methane potentials quite adequately. Both the experimental data and the simulations suggest a linear reduction of methane potential with respect to the increase in oxygen load within this range.

  4. Absence of PO2 change in fetal brain despite PO2 increase in placenta in response to maternal oxygen challenge.

    Science.gov (United States)

    Huen, I; Morris, D M; Wright, C; Sibley, C P; Naish, J H; Johnstone, E D

    2014-12-01

    Magnetic resonance imaging allows the noninvasive observation of PO2 changes between air breathing and oxygen breathing through quantification of the magnetic longitudinal relaxation time T1. Changes in PO2 are proportional to changes in the longitudinal relaxation rate ΔR1 (where ΔR1=1/T1oxygen-1/T1air). Knowledge of this response could inform clinical interventions using maternal oxygen administration antenatally to treat fetal growth restriction. We present in vivo measurements of the response of the fetal-placental unit to maternal hyperoxia. Prospective cohort. Large tertiary maternity hospital. Nine women undergoing low-risk pregnancy (21-33 weeks of gestation) and five nonpregnant adults. During imaging the air supply to mothers was changed from medical air (21% oxygen) to medical oxygen (100% oxygen) and T1 was monitored over time in both the placenta and fetal brain using a periodically repeated magnetic resonance imaging sequence. To demonstrate that the method could detect a brain response, brain responses from five normal adult volunteers were measured using a similar imaging protocol. Changes in T1 following oxygen challenge. No significant ΔR1 (P=0.42, paired t-test) was observed in fetal brains. A significant placental ΔR1 (P=0.0002, paired t-test) of 0.02±0.01/s (mean±SD) was simultaneously observed in the same participants. In the brains of the nonpregnant adults, a significant ΔR1 (P=0.01, paired t-test) of 0.005±0.002/s was observed. Short-term maternal oxygen administration does not improve fetal brain oxygenation, in contrast to the response observed in the adult brain. © 2014 Royal College of Obstetricians and Gynaecologists.

  5. [Correlation between the inspired fraction of oxygen, maternal partial oxygen pressure, and fetal partial oxygen pressure during cesarean section of normal pregnancies].

    Science.gov (United States)

    Castro, Carlos Henrique Viana de; Cruvinel, Marcos Guilherme Cunha; Carneiro, Fabiano Soares; Silva, Yerkes Pereira; Cabral, Antônio Carlos Vieira; Bessa, Roberto Cardoso

    2009-01-01

    Despite changes in pulmonary function, maternal oxygenation is maintained during obstetric regional blocks. But in those situations, the administration of supplementary oxygen to parturients is a common practice. Good fetal oxygenation is the main justification; however, this has not been proven. The objective of this randomized, prospective study was to test the hypothesis of whether maternal hyperoxia is correlated with an increase in fetal gasometric parameters in elective cesarean sections. Arterial blood gases of 20 parturients undergoing spinal block with different inspired fractions of oxygen were evaluated and correlated with fetal arterial blood gases. An increase in maternal inspired fraction of oxygen did not show any correlation with an increase of fetal partial oxygen pressure. Induction of maternal hyperoxia by the administration of supplementary oxygen did not increase fetal partial oxygen pressure. Fetal gasometric parameters did not change even when maternal parameters changed, induced by hyperoxia, during cesarean section under spinal block.

  6. Sulfur Concentration at Sulfide Saturation in Anhydrous Silicate Melts at Crustal Conditions

    Science.gov (United States)

    Liu, Y.; Samaha, N.; Baker, D. R.

    2006-05-01

    The sulfur concentration in silicate melts at sulfide saturation (SCSS) was experimentally investigated in a temperature range from 1250°C to 1450°C and a pressure range from 500 MPa to 1 GPa in a piston-cylinder apparatus. The investigated melt compositions varied from rhyolitic to basaltic. All experiments were saturated with a FeS melt. Temperature was confirmed to have a positive effect on the SCSS and no measurable pressure effect was observed. Oxygen fugacity was controlled to be either near the carbon-carbon monoxide buffer or one log unit above the nickel-nickel oxide buffer, and found to positively affect the SCSS. A series of models were constructed to predict the SCSS as a function of temperature, pressure, melt composition, oxygen fugacity and sulfur fugacity of the system. The coefficients were obtained by the regression of experimental data from this study and from data in the literature. The best model found for the prediction of the SCSS is: ln S (ppm) = 996/T + 9.875 + 0.997 ln MFM + 0.1901 ln fO2 - 0.0722 (P/T) -0.115 ln f S2, where P is in bar, T is in K, and MFM is a compositional parameter describing the melt based upon cation mole fractions: MFM = [Na + K + 2 (Ca + Mg+ Fe2+)]/[Si × (Al + Fe3+)]. This model predicts the SCSS in anhydrous silicate melts from rhyolitic to basaltic compositions at crustal conditions from 1 bar to 1.25 GPa, temperatures from ~1200 to 1400 C, and oxygen fugacities between approximately two log units below the fayalite-quartz-magnetite buffer and one log unit above the nickel-nickel oxide buffer. For cases where the oxygen and sulfur fugacities can not be adequately estimated a simpler model also works acceptably: ln S (ppm) = -5328/T + 8.431 + 1.244 ln MFM - 0.01704(P/T) + ln aFeS, where aFeS is the activity of FeS in the sulfide melt and is well approximated by a value of 1. Additional experiments were performed on other basalts in a temperature range from 1250 C to 1450 C at 1 GPa to test the models. The model

  7. Evaluation of Renal Oxygenation Level Changes after Water Loading Using Susceptibility-Weighted Imaging and T2* Mapping.

    Science.gov (United States)

    Ding, Jiule; Xing, Wei; Wu, Dongmei; Chen, Jie; Pan, Liang; Sun, Jun; Xing, Shijun; Dai, Yongming

    2015-01-01

    To assess the feasibility of susceptibility-weighted imaging (SWI) while monitoring changes in renal oxygenation level after water loading. Thirty-two volunteers (age, 28.0 ± 2.2 years) were enrolled in this study. SWI and multi-echo gradient echo sequence-based T2(*) mapping were used to cover the kidney before and after water loading. Cortical and medullary parameters were measured using small regions of interest, and their relative changes due to water loading were calculated based on baseline and post-water loading data. An intraclass correlation coefficient analysis was used to assess inter-observer reliability of each parameter. A receiver operating characteristic curve analysis was conducted to compare the performance of the two methods for detecting renal oxygenation changes due to water loading. Both medullary phase and medullary T2(*) values increased after water loading (p T2(*) changes (p > 0.05). Interobserver reliability was excellent for the T2(*) values, good for SWI cortical phase values, and moderate for the SWI medullary phase values. The area under receiver operating characteristic curve of the SWI medullary phase values was 0.85 and was not different from the medullary T2(*) value (0.84). Susceptibility-weighted imaging enabled monitoring changes in the oxygenation level in the medulla after water loading, and may allow comparable feasibility to detect renal oxygenation level changes due to water loading compared with that of T2(*) mapping.

  8. PRO-QUEST: a rapid assessment method based on progressive saturation for quantifying exchange rates using saturation times in CEST.

    Science.gov (United States)

    Demetriou, Eleni; Tachrount, Mohamed; Zaiss, Moritz; Shmueli, Karin; Golay, Xavier

    2018-03-05

    To develop a new MRI technique to rapidly measure exchange rates in CEST MRI. A novel pulse sequence for measuring chemical exchange rates through a progressive saturation recovery process, called PRO-QUEST (progressive saturation for quantifying exchange rates using saturation times), has been developed. Using this method, the water magnetization is sampled under non-steady-state conditions, and off-resonance saturation is interleaved with the acquisition of images obtained through a Look-Locker type of acquisition. A complete theoretical framework has been set up, and simple equations to obtain the exchange rates have been derived. A reduction of scan time from 58 to 16 minutes has been obtained using PRO-QUEST versus the standard QUEST. Maps of both T 1 of water and B 1 can simply be obtained by repetition of the sequence without off-resonance saturation pulses. Simulations and calculated exchange rates from experimental data using amino acids such as glutamate, glutamine, taurine, and alanine were compared and found to be in good agreement. The PRO-QUEST sequence was also applied on healthy and infarcted rats after 24 hours, and revealed that imaging specificity to ischemic acidification during stroke was substantially increased relative to standard amide proton transfer-weighted imaging. Because of the reduced scan time and insensitivity to nonchemical exchange factors such as direct water saturation, PRO-QUEST can serve as an excellent alternative for researchers and clinicians interested to map pH changes in vivo. © 2018 International Society for Magnetic Resonance in Medicine.

  9. Dissolved oxygen content as an index of water quality in San Vicente Bay, Chile (36 degrees 45'S).

    Science.gov (United States)

    Rudolph, Anny; Ahumada, Ramón; Pérez, Claudio

    2002-08-01

    The present report describes some effects of industrial and municipal effluents on the waters of San Vicente Bay. Analyses of the main substances contained in the fishing industry effluent suggest rating criteria based on the oxygen saturation of the water as an assessment of organic pollution. Six cruises were carried out throughout the Bay, from June to December 1996. Water samples were analyzed for dissolved oxygen, oil and grease content, and sediment samples for organic matter content. Water parameters (salinity, temperature) were used to characterize the Bay's hydrography, and to calculate values for oxygen saturation. The measurements demonstrated a local broad range of oxygen deficit, with a maximum of 45% in the winter to 95% in the spring. In November more than 65% of the Bay's area showed oxygen deficits greater than 40%. Organic matter was unusually high in sediments along the northern sector of the Bay. The results suggest that the oxygen depletion was a representative parameter for establishing a relative scale of water quality in this Bay.

  10. Mangiferin binding to serum albumin is non-saturable and induces conformational changes at high concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, P.G.; Barbosa, A.F. [Biochemistry Laboratory, Institute of Exact Sciences, Federal University of Alfenas, Unifal-MG, R. Gabriel Monteiro da Silva, 700, 37130-000 Alfenas, MG (Brazil); Saraiva, L.A. [Phytochemistry and Medicinal Chemistry Laboratory, Institute of Exact Sciences, Unifal-MG (Brazil); Camps, I. [Physics Laboratory, Institute of Exact Sciences, Unifal-MG (Brazil); Silveira, N.J.F. da [Bioinformatics Laboratory, Institute of Exact Sciences, Unifal-MG (Brazil); Veloso, M.P. [Phytochemistry and Medicinal Chemistry Laboratory, Institute of Exact Sciences, Unifal-MG (Brazil); Santos, M.H., E-mail: poliany.santos@gmail.com [Phytochemistry and Medicinal Chemistry Laboratory, Institute of Exact Sciences, Unifal-MG (Brazil); Schneedorf, J.M., E-mail: zemasfs@gmail.com [Biochemistry Laboratory, Institute of Exact Sciences, Federal University of Alfenas, Unifal-MG, R. Gabriel Monteiro da Silva, 700, 37130-000 Alfenas, MG (Brazil)

    2012-11-15

    The binding interaction between mangiferin (MGF), which a natural xanthone isolated from mangoes, and bovine serum albumin (BSA) was studied with absorbance and fluorescence spectroscopy, cyclic voltammetry and molecular modeling. The data were analyzed to assess the binding mechanism, effect of pH and ionic strength, conformational changes in the protein and electrical charge transfer involved. The MGF-BSA complex exhibited positive cooperativity with a 1:1 stoichiometry (K{sub d}=0.38 mmol L{sup -1}) for the first binding site and a non-saturable binding at high ligand concentrations. Furthermore, the data also suggest an increase in drug bioavailability in the acidic region and relatively low ionic strength values, which are close to physiological levels. The data suggest a specific electrostatic interaction together with hydrophobic effects and H-bonding displayed in MGF binding to the BSA IIA subdomain. Synchronous fluorescence spectra indicate that there are conformational changes in the polypeptide backbone upon ligand binding. Cyclic voltammetry indicates that there is an irreversible charge transfer between MGF and BSA that is modulated by diffusion on the electrode surface, where two electrons are transferred. These results can help the knowledge of the pharmacokinetic activities of natural or chemical xanthone-based drugs. - Highlights: Black-Right-Pointing-Pointer The MGF-BSA complex exhibited positive cooperativity beyond 1:1 stoichiometry. Black-Right-Pointing-Pointer The interaction of MGF with BSA is non-saturable at higher ligand concentration. Black-Right-Pointing-Pointer The binding was accomplished by H-bonding, hydrophobic and electrostatic forces. Black-Right-Pointing-Pointer The apparent binding constant for MGF-BSA was 0.38 mmol L{sup -1}. Black-Right-Pointing-Pointer MGF binds electrostatically to BSA, different from a hydrophobic interaction to HSA.

  11. Effects of carbogen plus fractionated irradiation on KHT tumor oxygenation

    International Nuclear Information System (INIS)

    Fenton, Bruce M.

    1997-01-01

    Background and purpose: Numerous studies have demonstrated improvements in the oxygenation of tumor cells following both irradiation and carbogen breathing. The current studies were initiated to measure the combined effects of carbogen inhalation plus single and multi-dose irradiation on tumor oxygen availability, to better define the underlying physiological relationships. Materials and methods: Using KHT murine sarcomas, radiation was delivered to the tumor-bearing legs of non-anesthetized mice. Tumors were quick-frozen prior to or following single or multifraction irradiation and carbogen breathing, and intravascular HbO 2 saturation profiles were determined cryospectrophotometrically. Results: HbO 2 levels for blood vessels located near the tumor surface initially decreased following 10 Gy irradiation, then increased and remained elevated. Interior HbO 2 levels remained unchanged. Following 2.5 Gy, HbO 2 changes were minimal. At 24 h following 10 Gy, HbO 2 levels were significantly increased compared to non-irradiated controls, and carbogen breathing produced no additional benefit. At 24 h following five fractions of 2 Gy, HbO 2 levels throughout the tumor volume were significantly higher in carbogen breathing animals than in air breathing controls. Conclusions: Although peripheral blood vessels demonstrated substantial improvements in oxygenation following irradiation, oxygen availability nearer the tumor center remained at very low levels. The utility of carbogen in enhancing tumor oxygen availability was maintained following five clinically relevant fractions. At higher doses, radiation-induced enhancements in HbO 2 levels overshadowed the carbogen effect. For either air or carbogen breathing, a decrease in the percentage of vessels with very low oxygen content did not appear to be a major factor in the reoxygenation of the KHT tumor

  12. Oxygen binding properties, capillary densities and heart weights in high altitude camelids.

    Science.gov (United States)

    Jürgens, K D; Pietschmann, M; Yamaguchi, K; Kleinschmidt, T

    1988-01-01

    The oxygen binding properties of the blood of the camelid species vicuna, llama, alpaca and dromedary camel were measured and evaluated with respect to interspecific differences. The highest blood oxygen affinity, not only among camelids but of all mammals investigated so far, was found in the vicuna (P50 = 17.6 Torr compared to 20.3-21.6 Torr in the other species). Low hematocrits (23-34%) and small red blood cells (21-30 microns 3) are common features of all camelids, but the lowest values are found in the Lama species. Capillary densities were determined in heart and soleus muscle of vicuna and llama. Again, the vicuna shows exceptional values (3720 cap/mm2 on average in the heart) for a mammal of this body size. Finally, heart weight as percent of body weight is higher in the vicuna (0.7-0.9%) than in the other camelids studied (0.5-0.7%). The possibility that these parameters, measured in New World tylopodes at sea level, are not likely to change considerably with transfer to high altitude, is discussed. In the vicuna, a unique combination of the following features seems to be responsible for an outstanding physical capability at high altitude: saturation of blood with oxygen in the lung is favored by a high blood oxygen affinity, oxygen supply being facilitated by low diffusion distances in the muscle tissue. Loading, as well as unloading, of oxygen is improved by a relatively high oxygen transfer conductance of the red blood cells, which is due to their small size and which compensates the negative effect of a low hematocrit on the oxygen conductance of blood.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Cascade damage in nickel: Production, saturation and recovery

    International Nuclear Information System (INIS)

    Birtcher, R.C.; Blewitt, T.H.

    1988-01-01

    Changes in the electrical resistivity and length were simultaneously measured during the bombardment of nickel at 70 K with 235 U fission fragments and during a subsequent isothermal annealing program. The resistivity changes and length changes were linearly related during the damage production for damage concentrations less 80% of the defect saturation limit. The initial ratio of the length change to the resistivity change was 8.4x10 4 /Ω m. At high damage concentrations, the length change increased at a slightly higher rate than the resistivity change. During isothermal annealing of the near-saturation defect concentration, the resistivity and the length changes had identical recoveries through stage I and most of stage II. During stage III annealing, the ratio of the length change to the resistivity change showed a small increase. At temperatures above 475 K, this ratio showed a marked increase as the resistivity change exhibited recovery without a corresponding recovery of the length change. These differences, which are attributed to the direct formation and growth of three-dimensional vacancy agglomerates, and results of tranmission electron microscopy suggest that the sign of the third derivative of the resistivity with respect to fast-neutron fluence (the sense of curvature in the damage rate) is positive for materials in which cascades collapse to loops, and negative for materials in which three-dimensional vacancy agglomerates are stable. (orig.)

  14. Gluon saturation in a saturated environment

    International Nuclear Information System (INIS)

    Kopeliovich, B. Z.; Potashnikova, I. K.; Schmidt, Ivan

    2011-01-01

    A bootstrap equation for self-quenched gluon shadowing leads to a reduced magnitude of broadening for partons propagating through a nucleus. Saturation of small-x gluons in a nucleus, which has the form of transverse momentum broadening of projectile gluons in pA collisions in the nuclear rest frame, leads to a modification of the parton distribution functions in the beam compared with pp collisions. In nucleus-nucleus collisions all participating nucleons acquire enhanced gluon density at small x, which boosts further the saturation scale. Solution of the reciprocity equations for central collisions of two heavy nuclei demonstrate a significant, up to several times, enhancement of Q sA 2 , in AA compared with pA collisions.

  15. Evaluación de parámetros fisiológicos en función de la saturación de oxigeno muscular en mujeres con sobrepeso y obesidad. [Evaluation physiological parameters depending on muscle oxygen saturation in overweight and obesity].

    Directory of Open Access Journals (Sweden)

    Aldo Alfonso Vasquez-Bonilla

    2017-01-01

    Full Text Available El objetivo de este estudio fue evaluar parámetros fisiológicos para comparar y correlacionar en función de la saturación de oxigeno muscular y hemoglobina total medida con espectroscopia de infrarrojo cercano no invasivo. La muestra (n=17 mujeres se dividieron en 2 grupos: sobrepeso/obesidad y normopeso, se valoró la composición corporal, parámetros fisiológicos, saturación de oxigeno muscular e indicie de esfuerzo percibido durante la prueba de esfuerzo incremental máxima en un cicloergometro en base a cuatro zonas metabólicas establecidas: fatmax, umbral aeróbico, umbral anaeróbico y zona de consumo máximo de oxígeno. Los resultados se analizaron utilizando el método estadístico Anova de un factor y la correlación de pearsón. Los resultados encontrados en el grupo normopeso la saturación de oxigeno muscular tiene correlación positiva alta con el vo2max durante la zona fatmax y umbral aeróbico (r=0,72- p=0,04 (r=0,77 – p=0,02, la frecuencia cardíaca de entrenamiento (r= -0,87 – p=0,01 tiene correlación negativa muy alta en la zona umbral anaeróbico, en el grupo sobrepeso obesidad no se encontró ninguna correlación. En conclusión las mujeres con normopeso la saturación de oxigeno muscular medida con espectroscopia de infrarrojo cercano no invasivo puede ser un buen parámetro fisiológico para programar ejercicio en la zonas fatmax, umbral aeróbico y umbral anaeróbico, pero en las mujeres con sobrepeso y obesidad se necesitan más estudios. Abstract The objective of this study was to compare physiological parameters and correlate function of muscle oxygen saturation and total hemoglobin measured with near-infrared spectroscopy noninvasive. The sample (n = 17 women were divided into 2 groups: overweight / obese and normal weight, was measured body composition, physiological parameters, saturation of muscle oxygen and index of perceived exertion during testing maximum incremental exercise on a cycle ergometer

  16. Hemodynamic parameters change earlier than tissue oxygen tension in hemorrhage.

    Science.gov (United States)

    Pestel, Gunther J; Fukui, Kimiko; Kimberger, Oliver; Hager, Helmut; Kurz, Andrea; Hiltebrand, Luzius B

    2010-05-15

    Untreated hypovolemia results in impaired outcome. This study tests our hypothesis whether general hemodynamic parameters detect acute blood loss earlier than monitoring parameters of regional tissue beds. Eight pigs (23-25 kg) were anesthetized and mechanically ventilated. A pulmonary artery catheter and an arterial catheter were inserted. Tissue oxygen tension was measured with Clark-type electrodes in the jejunal and colonic wall, in the liver, and subcutaneously. Jejunal microcirculation was assessed by laser Doppler flowmetry (LDF). Intravascular volume was optimized using difference in pulse pressure (dPP) to keep dPP below 13%. Sixty minutes after preparation, baseline measurements were taken. At first, 5% of total blood volume was withdrawn, followed by another 5% increment, and then in 10% increments until death. After withdrawal of 5% of estimated blood volume, dPP increased from 6.1% +/- 3.0% to 20.8% +/- 2.7% (P < 0.01). Mean arterial pressure (MAP), mean pulmonary artery pressure (PAP) and pulmonary artery occlusion pressure (PAOP) decreased with a blood loss of 10% (P < 0.01). Cardiac output (CO) changed after a blood loss of 20% (P < 0.05). Tissue oxygen tension in central organs, and blood flow in the jejunal muscularis decreased (P < 0.05) after a blood loss of 20%. Tissue oxygen tension in the skin, and jejunal mucosa blood flow decreased (P < 0.05) after a blood loss of 40% and 50%, respectively. In this hemorrhagic pig model systemic hemodynamic parameters were more sensitive to detect acute hypovolemia than tissue oxygen tension measurements or jejunal LDF measurements. Acute blood loss was detected first by dPP. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  17. Calculation on the heat of gasification for the saturated liquid of D2

    International Nuclear Information System (INIS)

    Ge Fangfang; China Academy of Engineering Physics, Mianyang; Zhu Zhenghe; Wang Hongbin; Zhou Weimin; Chen Hao; Liu Hongjie

    2005-01-01

    In general, the saturated stream is regarded as the ideal gas for calculating the heat of gasification for the saturated liquid. However, the result of calculation was not consistent with the general law if D 2 was treated as the ideal gas under T c =38.34 K, the critical temperature. Considering the change of the volume from the liquid state to the gas state, this paper implored the Clapeyron differential equation and the equation of vapor-liquid equilibrium, and then obtained the heat of gasification and the entropy from 20 K to 38 K and the saturation curve. The method avoided regarding the saturate gas D 2 as the ideal gas and ignoring the volume change from the liquid state to the gas state, improving the calculation exactitude. (authors)

  18. Adsorption of atomic oxygen on PdAg/Pd(111) surface alloys and coadsorption of CO

    Energy Technology Data Exchange (ETDEWEB)

    Farkas, Arnold P. [Institute of Surface Chemistry and Catalysis, Ulm University, D-89069 Ulm (Germany); Reaction Kinetics Research Group, University of Szeged, Chemical Research Center of the Hungarian Academy of Sciences, H-6720 Szeged (Hungary); Bansmann, Joachim; Diemant, Thomas; Behm, R. Juergen [Institute of Surface Chemistry and Catalysis, Ulm University, D-89069 Ulm (Germany)

    2011-07-01

    The interaction of dissociated oxygen with structurally well-defined PdAg/Pd(111) surface alloys and the coadsorption of CO was studied by high resolution electron energy loss spectroscopy (HREELS) and temperature-programmed desorption (TPD). After oxygen saturation of the non-modified Pd(111) surface at RT, we observed the formation of a prominent peak in the HREEL spectra at 60 meV corresponding to the perpendicular vibration of oxygen atoms adsorbed in threefold hollow sites. Deposition of small Ag amounts does not change the signal intensity of this peak; it decreases only above 20% Ag. Beyond this Ag content, the peak intensity steeply declines and disappears at around 55-60% Ag. CO coadsorption on the oxygen pre-covered surfaces at 120 K leads to the formation of additional features in HREELS. For a surface alloy with 29% Ag, three loss features due to CO adsorption in on-top, bridge, and threefold-hollow sites can be discriminated already after the lowest CO exposure. Annealing of the co-adsorbed layer to 200 K triggers a decrease of the oxygen concentration due to CO{sub 2} formation. These findings are corroborated by TPD spectra of the CO desorption and CO{sub 2} production.

  19. Impaired Muscle Oxygenation and Elevated Exercise Blood Pressure in Hypertensive Patients: Links With Vascular Stiffness.

    Science.gov (United States)

    Dipla, Konstantina; Triantafyllou, Areti; Koletsos, Nikolaos; Papadopoulos, Stavros; Sachpekidis, Vasileios; Vrabas, Ioannis S; Gkaliagkousi, Eugenia; Zafeiridis, Andreas; Douma, Stella

    2017-08-01

    This study examined in vivo (1) skeletal muscle oxygenation and microvascular function, at rest and during handgrip exercise, and (2) their association with macrovascular function and exercise blood pressure (BP), in newly diagnosed, never-treated patients with hypertension and normotensive individuals. Ninety-one individuals (51 hypertensives and 40 normotensives) underwent office and 24-hour ambulatory BP, arterial stiffness, and central aortic BP assessment, followed by a 5-minute arterial occlusion and a 3-minute submaximal handgrip exercise. Changes in muscle oxygenated and deoxygenated hemoglobin and tissue oxygen saturation were continuously monitored by near-infrared spectroscopy and beat-by-beat BP by Finapres. Hypertensives had higher ( P age and body mass index (BMI) adjusted). When exercising at the same submaximal intensity, hypertensives required a significantly greater ( P hypertension exhibit prominent reductions in in vivo indices of skeletal muscle oxidative capacity, suggestive of mitochondrial dysfunction, and blunted muscle microvascular reactivity. These dysfunctions were associated with higher aortic systolic BP and arterial stiffness. Dysregulations in muscle oxygen delivery/utilization and microvascular stiffness, in hypertensive patients, partially contribute to their exaggerated BP during exercise. © 2017 American Heart Association, Inc.

  20. A new theoretical interpretation of Archie's saturation exponent

    Directory of Open Access Journals (Sweden)

    P. W. J. Glover

    2017-07-01

    Full Text Available This paper describes the extension of the concepts of connectedness and conservation of connectedness that underlie the generalized Archie's law for n phases to the interpretation of the saturation exponent. It is shown that the saturation exponent as defined originally by Archie arises naturally from the generalized Archie's law. In the generalized Archie's law the saturation exponent of any given phase can be thought of as formally the same as the phase (i.e. cementation exponent, but with respect to a reference subset of phases in a larger n-phase medium. Furthermore, the connectedness of each of the phases occupying a reference subset of an n-phase medium can be related to the connectedness of the subset itself by Gi = GrefSini. This leads naturally to the idea of the term Sini for each phase i being a fractional connectedness, where the fractional connectednesses of any given reference subset sum to unity in the same way that the connectednesses sum to unity for the whole medium. One of the implications of this theory is that the saturation exponent of any phase can be now be interpreted as the rate of change of the fractional connectedness with saturation and connectivity within the reference subset.

  1. CLIMATE CHANGE. Long-term climate forcing by atmospheric oxygen concentrations.

    Science.gov (United States)

    Poulsen, Christopher J; Tabor, Clay; White, Joseph D

    2015-06-12

    The percentage of oxygen in Earth's atmosphere varied between 10% and 35% throughout the Phanerozoic. These changes have been linked to the evolution, radiation, and size of animals but have not been considered to affect climate. We conducted simulations showing that modulation of the partial pressure of oxygen (pO2), as a result of its contribution to atmospheric mass and density, influences the optical depth of the atmosphere. Under low pO2 and a reduced-density atmosphere, shortwave scattering by air molecules and clouds is less frequent, leading to a substantial increase in surface shortwave forcing. Through feedbacks involving latent heat fluxes to the atmosphere and marine stratus clouds, surface shortwave forcing drives increases in atmospheric water vapor and global precipitation, enhances greenhouse forcing, and raises global surface temperature. Our results implicate pO2 as an important factor in climate forcing throughout geologic time. Copyright © 2015, American Association for the Advancement of Science.

  2. Determination of saturation functions and wettability for chalk based on measured fluid saturations

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, D.; Bech, N.; Moeller Nielsen, C.

    1998-08-01

    The end effect of displacement experiments on low permeable porous media is used for determination of relative permeability functions and capillary pressure functions. Saturation functions for a drainage process are determined from a primary drainage experiment. A reversal of the flooding direction creates an intrinsic imbibition process in the sample, which enables determination if imbibition saturation functions. The saturation functions are determined by a parameter estimation technique. Scanning effects are modelled by the method of Killough. Saturation profiles are determined by NMR. (au)

  3. Effects of midazolam and morphine on cerebral oxygenation and hemodynamics in ventilated premature infants.

    Science.gov (United States)

    van Alfen-van der Velden, A A E M; Hopman, J C W; Klaessens, J H G M; Feuth, T; Sengers, R C A; Liem, K D

    2006-01-01

    Midazolam sedation and morphine analgesia are commonly used in ventilated premature infants. To evaluate the effects of midazolam versus morphine infusion on cerebral oxygenation and hemodynamics in ventilated premature infants. 11 patients (GA 26.6-33.0 weeks, BW 780-2,335 g) were sedated with midazolam (loading dose 0.2 mg/kg, maintenance 0.2 mg/kg/h) and 10 patients (GA 26.4-33.3 weeks, BW 842-1,955 g) were sedated with morphine (loading dose 0.05 mg/kg, maintenance 0.01 mg/kg/h). Changes in oxyhemoglobin (Delta cO2Hb) and deoxyhemoglobin (Delta cHHb) were assessed using near infrared spectrophotometry. Changes in cHbD (= Delta cO(2)Hb - Delta cHHb) reflect changes in cerebral blood oxygenation and changes in concentration of total hemoglobin (Delta ctHb = Delta cO2Hb + Delta cHHb) represent changes in cerebral blood volume (DeltaCBV). Changes in cerebral blood flow velocity (DeltaCBFV) were intermittently measured using Doppler ultrasound. Heart rate (HR), mean arterial blood pressure (MABP), arterial oxygen saturation (saO2) and transcutaneous measured pO2 (tcpO2) and pCO2 (tcpCO2) were continuously registered. Statistical analyses were carried out using linear mixed models to account for the longitudinal character study design. Within 15 min after the loading dose of midazolam, a decrease in saO2, tcpO2 and cHbD was observed in 5/11 infants. In addition, a fall in MABP and CBFV was observed 15 min after midazolam administration. Immediately after morphine infusion a decrease in saO2, tcpO2 and cHbD was observed in 6/10 infants. Furthermore, morphine infusion resulted in a persistent increase in CBV. Administration of midazolam and morphine in ventilated premature infants causes significant changes in cerebral oxygenation and hemodynamics, which might be harmful. Copyright 2006 S. Karger AG, Basel.

  4. Gradually Increased Oxygen Administration Improved Oxygenation and Mitigated Oxidative Stress after Resuscitation from Severe Hemorrhagic Shock.

    Science.gov (United States)

    Luo, Xin; Yin, Yujing; You, Guoxing; Chen, Gan; Wang, Ying; Zhao, Jingxiang; Wang, Bo; Zhao, Lian; Zhou, Hong

    2015-11-01

    The optimal oxygen administration strategy during resuscitation from hemorrhagic shock (HS) is still controversial. Improving oxygenation and mitigating oxidative stress simultaneously seem to be contradictory goals. To maximize oxygen delivery while minimizing oxidative damage, the authors proposed the notion of gradually increased oxygen administration (GIOA), which entails making the arterial blood hypoxemic early in resuscitation and subsequently gradually increasing to hyperoxic, and compared its effects with normoxic resuscitation, hyperoxic resuscitation, and hypoxemic resuscitation in severe HS. Rats were subjected to HS, and on resuscitation, the rats were randomly assigned to four groups (n = 8): the normoxic, the hyperoxic, the hypoxemic, and the GIOA groups. Rats were observed for an additional 1 h. Hemodynamics, acid-base status, oxygenation, and oxidative injury were observed and evaluated. Central venous oxygen saturation promptly recovered only in the hyperoxic and the GIOA groups, and the liver tissue partial pressure of oxygen was highest in the GIOA group after resuscitation. Oxidative stress in GIOA group was significantly reduced compared with the hyperoxic group as indicated by the reduced malondialdehyde content, increased catalase activity, and the lower histologic injury scores in the liver. In addition, the tumor necrosis factor-α and interleukin-6 expressions in the liver were markedly decreased in the GIOA group than in the hyperoxic and normoxic groups as shown by the immunohistochemical staining. GIOA improved systemic/tissue oxygenation and mitigated oxidative stress simultaneously after resuscitation from severe HS. GIOA may be a promising strategy to improve resuscitation from HS and deserves further investigation.

  5. Chemisorption of oxygen and subsequent reactions on low index surfaces of β-Mo2C

    DEFF Research Database (Denmark)

    Shi, Xue Rong; Wang, Shengguang; Wang, Jianguo

    2016-01-01

    to the carbon vacancy were identified. We examined the effect of oxygen coverage on the morphology of β-Mo2C by plotting the equilibrium crystal shape. Thermodynamic effect of temperature and reactant or product pressure on the CO/CO2 desorption were investigated. The CO/CO2 desorption is more favorable...... at the saturated oxygen coverage than the low oxygen coverage thermodynamically. The subsequent oxygen diffusion to the carbon vacancy after CO/CO2 desorption may happen depending on the surfaces and oxygen coverage....

  6. Nitrogen Saturation in Highly Retentive Watersheds?

    Science.gov (United States)

    Daley, M. L.; McDowell, W. H.

    2009-12-01

    Watershed managers are often concerned with minimizing the amount of N delivered to N-limited estuaries and coastal zones. A major concern is that watersheds might reach N saturation, in which N delivered to coastal zones increases due to declines in the efficiency of N retention despite constant or even reduced N inputs. We have quantified long-term changes in N inputs (atmospheric deposition, imported food and agricultural fertilizers), outputs (N concentration and export) and retention in the urbanizing Lamprey River watershed in coastal NH. Overall, the Lamprey watershed is 70% forested, receives about 13.5 kg N/ha/yr and has a high rate of annual N retention (85%). Atmospheric deposition (8.7 kg/ha/yr) is the largest N input to the watershed. Of the 2.2 kg N/ha/yr exported in the Lamprey River, dissolved organic N (DON) is the dominant form (50% of total) and it varies spatially throughout the watershed with wetland cover. Nitrate accounts for 30% of the N exported, shows a statistically significant increase from 1999 to 2009, and its spatial variability in both concentration and export is related to human population density. In sub-basins throughout the Lamprey, inorganic N retention is high (85-99%), but the efficiency of N retention declines sharply with increased human population density and associated anthropogenic N inputs. N assimilation in the vegetation, denitrification to the atmosphere and storage in the groundwater pool could all be important contributors to the current high rates of N retention. The temporal and spatial patterns that we have observed in nitrate concentration and export are driven by increases in N inputs and impervious surfaces over time, but the declining efficiency of N retention suggests that the watershed may also be reaching N saturation. The downstream receiving estuary, Great Bay, already suffers from low dissolved oxygen levels and eelgrass loss in part due to N loading from the Lamprey watershed. Targeting and reducing

  7. Relation between electric properties and water saturation for hematitic sandstone with frequency

    Directory of Open Access Journals (Sweden)

    M. M. Gomaa

    2008-06-01

    Full Text Available This paper focuses on the effect of water saturation on A. C. electrical conductivity and dielectric constant of fully and partially saturated hematitic sandstone sample (Aswan area, Egypt. The saturation of the sample was changed from partial to full saturation. Complex resistivity measurements at room temperature (~16°C, were performed in the frequency range from 0.1 Hz to 100 KHz. Experimental electrical spectra indicate, generally, that the electrical conductivity and dielectric constant vary strongly with water saturations and frequency. The low frequency electrical conductivity and dielectric constant are mainly controlled by surface conduction and polarization of the electrical double layer. The behaviour of the electrical conductivity and dielectric constant, with increasing water content, were argued to the orientational polarization of bound water for very low saturations, displacement of the excess surface charges for relatively low saturations, and free exchange of excess ions in double layer with the bulk electrolyte and generation of transient diffusion potentials which lag behind the applied field for high saturations.

  8. A Contribution to the Problem of Initiation of a Combustion Source in an Oil-Saturated Bed

    Science.gov (United States)

    Koznacheev, I. A.; Dobrego, K. V.

    2013-11-01

    The problem on in-situ self-ignition of an oil-saturated bed under the conditions of forced filtration of an oxygen-containing gas has been solved with analytical and numerical methods with account of the burnout of a deficient gas component. The influence of the burnout of this component and of convective removal of heat from the bed on the time of its self-ignition has been determined. Recommendations for the optimum regime of initiation of the self-ignition of the bed with account of variation of the blast flow rate and the oxygen content have been given.

  9. Effect of oxygen at low and high light intensities on the growth of Neochloris oleoabundans

    NARCIS (Netherlands)

    Sousa, C.A.; Compadre, A.; Vermuë, M.H.; Wijffels, R.H.

    2013-01-01

    The effect of partial oxygen pressure on growth of Neochloris oleoabundans was studied at near-saturating light intensity in a fully-controlled photobioreactor. At the partial oxygen pressures tested (PO2=0.24; 0.42; 0.63; 0.84 bar), the specific growth rate was 1.36; 1.16; 0.93 and 0.68 day-1,

  10. Influence of preadsorbed oxygen on the sign and magnitude of the chemisorption-induced resistance change for H2 adsorption onto Fe films

    Science.gov (United States)

    Shanabarger, M. R.

    1986-01-01

    Measurements have been made of the chemisorption-induced resistance change for H2 adsorbed onto Fe film substrates predosed with fixed coverages of chemisorbed oxygen. The measurements were made at temperatures from 295 to 340 K and for estimated oxygen coverages of less than 0.1 monolayers. Two distinct resistance change components were observed in both the adsorption kinetics and the equilibrium isotherms: a positive component which is associated with the adsorption of H2 onto a clean Fe surface, and a negative component which was correlated with the presence of the chemisorbed oxygen. The resistance change isotherms can be fit with a model which assumes that each of the resistance change components result from dissociative chemisorbed hydrogen. Possible mechanisms for the chemisorbed-oxygen-induced negative resistance change are discussed.

  11. Cerebral oxygenation is associated with neurodevelopmental outcome of preterm children at age 2 to 3 years

    NARCIS (Netherlands)

    Verhagen, Elise A.; Van Braeckel, Koenraad N. J. A.; van der Veere, Christa N.; Groen, Henk; Dijk, Peter H.; Hulzebos, Christian V.; Bos, Arend F.

    AIM: The aim of the study was to determine whether regional cerebral tissue oxygen saturation (rc SO2 ) and fractional tissue oxygen extraction (FTOE), using near-infrared spectroscopy, are associated with neurodevelopmental outcome of preterm infants. METHOD: We measured rc SO2 on days 1, 2, 3, 4,

  12. Effects of soil water saturation on sampling equilibrium and kinetics of selected polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Kim, Pil-Gon; Roh, Ji-Yeon; Hong, Yongseok; Kwon, Jung-Hwan

    2017-10-01

    Passive sampling can be applied for measuring the freely dissolved concentration of hydrophobic organic chemicals (HOCs) in soil pore water. When using passive samplers under field conditions, however, there are factors that might affect passive sampling equilibrium and kinetics, such as soil water saturation. To determine the effects of soil water saturation on passive sampling, the equilibrium and kinetics of passive sampling were evaluated by observing changes in the distribution coefficient between sampler and soil (K sampler/soil ) and the uptake rate constant (k u ) at various soil water saturations. Polydimethylsiloxane (PDMS) passive samplers were deployed into artificial soils spiked with seven selected polycyclic aromatic hydrocarbons (PAHs). In dry soil (0% water saturation), both K sampler/soil and k u values were much lower than those in wet soils likely due to the contribution of adsorption of PAHs onto soil mineral surfaces and the conformational changes in soil organic matter. For high molecular weight PAHs (chrysene, benzo[a]pyrene, and dibenzo[a,h]anthracene), both K sampler/soil and k u values increased with increasing soil water saturation, whereas they decreased with increasing soil water saturation for low molecular weight PAHs (phenanthrene, anthracene, fluoranthene, and pyrene). Changes in the sorption capacity of soil organic matter with soil water content would be the main cause of the changes in passive sampling equilibrium. Henry's law constant could explain the different behaviors in uptake kinetics of the selected PAHs. The results of this study would be helpful when passive samplers are deployed under various soil water saturations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Analysis of γ-ray irradiated pasteurized agaricus (Agaricus blazei Murill) by ESR in oxygen-free atmosphere

    International Nuclear Information System (INIS)

    Kemeya, Hiromi; Ukai, Mitsuko

    2007-01-01

    Agaricus (Agaricus blazei Murill) is one of a popular crude drug in Japan and East Asia countries. The crude drugs originating from natural raw products are easy to be contaminated by microorganism. Radiation method has been introduced as the sterilization technology for crude drugs. ESR has been used for the detection of radicals in irradiated drugs. Using ESR, we detected radical species in Agaricus before and after the gamma ray pasteurization. The ESR spectrum consists of a broad sextet centered at g=2.0, a singlet at same g-value and a singlet at g=4.0. We found that relaxation times of radicals in Agaricus varied by the presence of oxygen. Upon substitution of air by Ar, i.e., the absent of oxygen in the ESR sample tube, the T 1 value became 10 times larger than the presence of oxygen. Accordingly, the progressive saturation curve indicates more immediate saturation under the Ar than air atmosphere. Radicals, produced by the γ-ray irradiation to Agaricus, are very sensitive to oxygen. We concluded that ESR spectrum of irradiated Agaricus sample in the absence of oxygen is useful for the detection of dose level of γ-ray irradiation. (author)

  14. Prognostic value of brachioradialis muscle oxygen saturation index and vascular occlusion test in septic shock patients.

    Science.gov (United States)

    Marín-Corral, J; Claverias, L; Bodí, M; Pascual, S; Dubin, A; Gea, J; Rodriguez, A

    2016-05-01

    To compare rSO2 (muscle oxygen saturation index) static and dynamic variables obtained by NIRS (Near Infrared Spectroscopy) in brachioradialis muscle of septic shock patients and its prognostic implications. Prospective and observational study. Intensive care unit. Septic shock patients and healthy volunteers. The probe of a NIRS device (INVOS 5100) was placed on the brachioradialis muscle during a vascular occlusion test (VOT). Baseline, minimum and maximum rSO2 values, deoxygenation rate (DeOx), reoxygenation slope (ReOx) and delta value. Septic shock patients (n=35) had lower baseline rSO2 (63.8±12.2 vs. 69.3±3.3%, p<0.05), slower DeOx (-0.54±0.31 vs. -0.91±0.35%/s, p=0.001), slower ReOx (2.67±2.17 vs. 9.46±3.5%/s, p<0.001) and lower delta (3.25±5.71 vs. 15.1±3.9%, p<0.001) when compared to healthy subjects (n=20). Among septic shock patients, non-survivors showed lower baseline rSO2 (57.0±9.6 vs. 69.8±11.3%, p=0.001), lower minimum rSO2 (36.0±12.8 vs. 51.3±14.8%, p<0.01) and lower maximum rSO2 values (60.6±10.6 vs. 73.3±11.2%, p<0.01). Baseline rSO2 was a good mortality predictor (AUC 0.79; 95%CI: 0.63-0.94, p<0.01). Dynamic parameters obtained with VOT did not improve the results. Septic shock patients present an important alteration of microcirculation that can be evaluated by NIRS with prognostic implications. Monitoring microvascular reactivity in the brachioradialis muscle using VOT with our device does not seem to improve the prognostic value of baseline rSO2. Copyright © 2015 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  15. Evaluation of renal oxygenation level changes after water loading using susceptibility-weighted imaging and T2{sup *} mapping

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Jiule; Xing, Wei; Chen, Jie; Pan, Liang; Sun, Jun; Xing, Shi Jun [Dept. of Radiology, Third Affiliated Hospital of Suzhou University, Changzhou (China); Wu, Dong Mei [Shanghai Key Laboratory of Magnetic Resonance Imaging, East China Normal University, Shanghai (China); Dai, Yong Ming [Philips Healthcare, Shanghai (China)

    2015-08-15

    To assess the feasibility of susceptibility-weighted imaging (SWI) while monitoring changes in renal oxygenation level after water loading. Thirty-two volunteers (age, 28.0 ± 2.2 years) were enrolled in this study. SWI and multi-echo gradient echo sequence-based T2{sup *} mapping were used to cover the kidney before and after water loading. Cortical and medullary parameters were measured using small regions of interest, and their relative changes due to water loading were calculated based on baseline and post-water loading data. An intraclass correlation coefficient analysis was used to assess inter-observer reliability of each parameter. A receiver operating characteristic curve analysis was conducted to compare the performance of the two methods for detecting renal oxygenation changes due to water loading. Both medullary phase and medullary T2{sup *} values increased after water loading (p < 0.001), although poor correlations were found between the phase changes and the T2{sup *} changes (p > 0.05). Interobserver reliability was excellent for the T2{sup *} values, good for SWI cortical phase values, and moderate for the SWI medullary phase values. The area under receiver operating characteristic curve of the SWI medullary phase values was 0.85 and was not different from the medullary T2{sup *} value (0.84). Susceptibility-weighted imaging enabled monitoring changes in the oxygenation level in the medulla after water loading, and may allow comparable feasibility to detect renal oxygenation level changes due to water loading compared with that of T2{sup *} mapping.

  16. EFFECT OF MODERATE ALTITUDE ON PERIPHERAL MUSCLE OXYGENATION DURING LEG RESISTANCE EXERCISE IN YOUNG MALES

    Directory of Open Access Journals (Sweden)

    Toshio Matsuoka

    2004-09-01

    Full Text Available Training at moderate altitude (~1800m is often used by athletes to stimulate muscle hypoxia. However, limited date is available on peripheral muscle oxidative metabolism at this altitude (1800AL. The purpose of this study was to determine whether acute exposure to 1800AL alters muscle oxygenation in the vastus lateralis muscle during resistance exercise. Twenty young active male subjects (aged 16 - 21 yr performed up to 50 repetitions of the parallel squat at 1800AL and near sea level (SL. They performed the exercise protocol within 3 h after arrival at 1800 AL. During the exercise, the changes in oxygenated hemoglobin (OxyHb in the vastus lateralis muscle, arterial oxygen saturation (SpO2, and heart rate were measured using near infrared continuous wave spectroscopy (NIRcws and pulse oximetry, respectively. Changes in OxyHb were expressed by Deff defined as the relative index of the maximum change ratio (% from the resting level. OxyHb in the vastus lateralis muscle decreased dramatically from the resting level immediately after the start of exercise at both altitudes. The Deff during exercise was significantly (p < 0.001 lower at 1800AL (60.4 ± 6.2 % than at near SL (74.4 ± 7.6 %. SpO2 during exercise was significantly (p < 0.001 lower at 1800AL (92.0 ± 1.7 % than at near SL (96.7 ± 1.2 %. Differences (SL - 1800AL in Deff during exercise correlated fairly strongly with differences in SpO2 during exercise (r = 0.660. These results suggested that acute exposure to moderate altitude caused a more dramatical decrease in peripheral muscle oxygenation during leg resistance exercise. It is salient to note, therefore , that peripheral muscle oxygenation status at moderate altitude could be evaluated using NIRcws and that moderate altitudes might be effectively used to apply hypoxic stress on peripheral muscles.

  17. Heating of a fully saturated darcian half-space: Pressure generation, fluid expulsion, and phase change

    Science.gov (United States)

    Delaney, P.

    1984-01-01

    Analytical solutions are developed for the pressurization, expansion, and flow of one- and two-phase liquids during heating of fully saturated and hydraulically open Darcian half-spaces subjected to a step rise in temperature at its surface. For silicate materials, advective transfer is commonly unimportant in the liquid region; this is not always the case in the vapor region. Volume change is commonly more important than heat of vaporization in determining the position of the liquid-vapor interface, assuring that the temperatures cannot be determined independently of pressures. Pressure increases reach a maximum near the leading edge of the thermal front and penetrate well into the isothermal region of the body. Mass flux is insensitive to the hydraulic properties of the half-space. ?? 1984.

  18. Physical changes in MX-80 bentonite saturated under thermal gradient

    International Nuclear Information System (INIS)

    Villar, Maria Victoria; Gomez-Espina, Roberto; Gutierrez-Nebot, Luis; Campos, Rocio; Barrios, Iciar

    2012-01-01

    Document available in extended abstract form only. This study was developed in the framework of the Temperature Buffer Test (TBT project), which was a full-scale test for HLW disposal that aimed at improving the understanding of the thermo-hydro-mechanical (THM) behaviour of buffers with a temperature around and above 100 deg. C during the water saturation transient. The French organisation ANDRA run this test at the Aespoe HRL in cooperation with SKB (Svensk Kaernbraenslehantering AB 2005). To simulate the conditions of the field test in the laboratory, 20-cm high columns of MX80 bentonite compacted at dry density 1.70 g/cm 3 with an initial water content of 16 percent were submitted in thermo-hydraulic cells to heating and hydration by opposite ends for different periods of time (TH test). The temperature at the bottom of the columns was set at 140 deg. C and on top at 30 C, and deionised water was injected on top at a pressure of 0.01 MPa. The tests were running for 337, 496 and 1510 days. Upon dismantling water content, dry density, specific surface area, porosity and basal spacings, among others, were determined in different positions along the bentonite columns. The strong gradients developed are remarkable. In the shorter tests the water content decreased below the initial value in the 7 cm closest to the heater, whereas in the longer test the decrease below the initial value took place only in the 5 cm closest to the heater. In the remaining part of the columns the water content increased with respect to the initial value, particularly so in the longest test. The dry density along the bentonite changed accordingly, decreasing in the hydrated areas below the initial value and increasing near the heater. The decrease in dry density is due to the swelling of the bentonite upon saturation, while the dry density increase results from the combination of two processes: the compression of the dry areas exerted by the hydrated bentonite, and the shrinkage due to the

  19. Spontaneous calcium waves in Bergman glia increase with age and hypoxia and may reduce tissue oxygen.

    Science.gov (United States)

    Mathiesen, Claus; Brazhe, Alexey; Thomsen, Kirsten; Lauritzen, Martin

    2013-02-01

    Glial calcium (Ca(2+)) waves constitute a means to spread signals between glial cells and to neighboring neurons and blood vessels. These waves occur spontaneously in Bergmann glia (BG) of the mouse cerebellar cortex in vivo. Here, we tested three hypotheses: (1) aging and reduced blood oxygen saturation alters wave activity; (2) glial Ca(2+) waves change cerebral oxygen metabolism; and (3) neuronal and glial wave activity is correlated. We used two-photon microscopy in the cerebellar cortexes of adult (8- to 15-week-old) and aging (48- to 80-week-old) ketamine-anesthetized mice after bolus loading with OGB-1/AM and SR101. We report that the occurrence of spontaneous waves is 20 times more frequent in the cerebellar cortex of aging as compared with adult mice, which correlated with a reduction in resting brain oxygen tension. In adult mice, spontaneous glial wave activity increased on reducing resting brain oxygen tension, and ATP-evoked glial waves reduced the tissue O(2) tension. Finally, although spontaneous Purkinje cell (PC) activity was not associated with increased glia wave activity, spontaneous glial waves did affect intracellular Ca(2+) activity in PCs. The increased wave activity during aging, as well as low resting brain oxygen tension, suggests a relationship between glial waves, brain energy homeostasis, and pathology.

  20. Mechanics of non-saturated soils

    International Nuclear Information System (INIS)

    Coussy, O.; Fleureau, J.M.

    2002-01-01

    This book presents the different ways to approach the mechanics of non saturated soils, from the physico-chemical aspect to the mechanical aspect, from the experiment to the theoretical modeling, from the laboratory to the workmanship, and from the microscopic scale to the macroscopic one. Content: water and its representation; experimental bases of the behaviour of non-saturated soils; transfer laws in non-saturated environment; energy approach of the behaviour of non-saturated soils; homogenization for the non-saturated soils; plasticity and hysteresis; dams and backfilling; elaborated barriers. (J.S.)

  1. Study of dimensional changes during redox cycling of oxygen carrier materials for chemical looping combustion

    NARCIS (Netherlands)

    Fossdal, A.; Darell, O.; Lambert, A.; Schols, E.; Comte, E.; Leenman, R.N.; Blom, R.

    2015-01-01

    Dimensional and phase changes of four candidate oxygen carrier materials for chemical looping combustion are investigated by dilatometry and high-temperature X-ray diffraction during four redox cycles. NiO/Ni2AlO4 does not exhibit significant dimensional changes during cycling, and it is shown that

  2. Biogeochemical modelling of dissolved oxygen in a changing ocean

    Science.gov (United States)

    Andrews, Oliver; Buitenhuis, Erik; Le Quéré, Corinne; Suntharalingam, Parvadha

    2017-08-01

    Secular decreases in dissolved oxygen concentration have been observed within the tropical oxygen minimum zones (OMZs) and at mid- to high latitudes over the last approximately 50 years. Earth system model projections indicate that a reduction in the oxygen inventory of the global ocean, termed ocean deoxygenation, is a likely consequence of on-going anthropogenic warming. Current models are, however, unable to consistently reproduce the observed trends and variability of recent decades, particularly within the established tropical OMZs. Here, we conduct a series of targeted hindcast model simulations using a state-of-the-art global ocean biogeochemistry model in order to explore and review biases in model distributions of oceanic oxygen. We show that the largest magnitude of uncertainty is entrained into ocean oxygen response patterns due to model parametrization of pCO2-sensitive C : N ratios in carbon fixation and imposed atmospheric forcing data. Inclusion of a pCO2-sensitive C : N ratio drives historical oxygen depletion within the ocean interior due to increased organic carbon export and subsequent remineralization. Atmospheric forcing is shown to influence simulated interannual variability in ocean oxygen, particularly due to differences in imposed variability of wind stress and heat fluxes. This article is part of the themed issue 'Ocean ventilation and deoxygenation in a warming world'.

  3. Hollow Nanospheres with Fluorous Interiors for Transport of Molecular Oxygen in Water

    KAUST Repository

    Vu, Khanh B.

    2016-08-11

    A dispersion system for saturated fluorocarbon (SFC) liquids based on permeable hollow nanospheres with fluorous interiors is described. The nanospheres are well dispersible in water and are capable of immediate uptake of SFCs. The nanosphere shells are gas-permeable and feature reactive functional groups for easy modification of the exterior. These features make the SFC-filled nanospheres promising vehicles for respiratory oxygen storage and transport. Uptake of molecular oxygen into nanosphere-stabilized SFC dispersions is demonstrated.

  4. Numerical Study of Frequency-dependent Seismoelectric Coupling in Partially-saturated Porous Media

    Directory of Open Access Journals (Sweden)

    Djuraev Ulugbek

    2017-01-01

    Full Text Available The seismoelectric phenomenon associated with propagation of seismic waves in fluid-saturated porous media has been studied for many decades. The method has a great potential to monitor subsurface fluid saturation changes associated with production of hydrocarbons. Frequency of the seismic source has a significant impact on measurement of the seismoelectric effects. In this paper, the effects of seismic wave frequency and water saturation on the seismoelectric response of a partially-saturated porous media is studied numerically. The conversion of seismic wave to electromagnetic wave was modelled by extending the theoretically developed seismoelectric coupling coefficient equation. We assumed constant values of pore radius and zeta-potential of 80 micrometers and 48 microvolts, respectively. Our calculations of the coupling coefficient were conducted at various water saturation values in the frequency range of 10 kHz to 150 kHz. The results show that the seismoelectric coupling is frequency-dependent and decreases exponentially when frequency increases. Similar trend is seen when water saturation is varied at different frequencies. However, when water saturation is less than about 0.6, the effect of frequency is significant. On the other hand, when the water saturation is greater than 0.6, the coupling coefficient shows monotonous trend when water saturation is increased at constant frequency.

  5. The Effect of Chronic Hypercapnia on Oxygen Affinity and 2, 3 Diphosphoglycerate as Related to Submarine Exposure

    Science.gov (United States)

    The relationship between oxygen affinity and 2,3 diphosphoglycerate (2,3 DPG) in the red cell has been studied in chronic hypercapnia induced by...initial values after seven days of exposure. Both oxygen half-saturation pressure (P50) and the level of 2,3 DPG of the red cells followed the time

  6. Regional oxygen saturation index (rSO2) in brachioradialis and deltoid muscle. Correlation and prognosis in patients with respiratory sepsis.

    Science.gov (United States)

    Rodríguez, A; Claverias, L; Marín, J; Magret, M; Rosich, S; Bodí, M; Trefler, S; Pascual, S; Gea, J

    2015-03-01

    To compare oxygen saturation index (rSO2) obtained simultaneously in two different brachial muscles. Prospective and observational study. Intensive care unit. Critically ill patients with community-acquired pneumonia. Two probes of NIRS device (INVOS 5100) were simultaneously placed on the brachioradialis (BR) and deltoid (D) muscles. rSO2 measurements were recorded at baseline (ICU admission) and at 24h. Demographic and clinical variables were registered. Pearson's correlation coefficient was used to assess the association between continuous variables. The consistency of the correlation was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman plot. The predictive value of the rSO2 for mortality was calculated by ROC curve. Nineteen patients were included with an ICU mortality of 21.1%. The rSO2 values at baseline and at 24h were significantly higher in D than in BR muscle. Values obtained simultaneously in both limbs showed a strong correlation and adequate consistency: BR (r=0.95; p0.001) but a wide limit of agreement. Non-survivors had rSO2 values significantly lower than survivors at all times of the study. No patient with rSO2 >60% in BR died, and only 17.6% died with an rSO2 value >60% in D. Both muscles showed consistent discriminatory power for mortality. Both BR and D muscles were appropriate for measuring rSO2. Copyright © 2013 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  7. Healthy Dental Pulp Oxygen Saturation Rates in Subjects with Homozygous Sickle Cell Anemia: A Cross-Sectional Study Nested in a Cohort.

    Science.gov (United States)

    Souza, Soraia de Fátima Carvalho; Thomaz, Erika Bárbara Abreu Fonseca; Costa, Cyrene Piazera Silva

    2017-12-01

    To compare the percentage of arterial oxygen saturation (SpO 2 ) in healthy teeth with confirmed pulp vitality between individuals with sickle cell anemia (HbSS) and normal hemoglobin A (HbAA). This is a cross-sectional study nested within a cohort. Samples (n = 2543) comprised teeth with intact crowns and pulp vitality confirmed by thermal sensitivity tests and no history of caries, periodontal disease, or dental trauma. A total of 728 teeth of 113 individuals with HbSS and 1815 teeth of 246 individuals with HbAA were evaluated. Data analysis was performed using the χ 2 and Mann-Whitney tests and Spearman correlation analysis (α = 0.05). The study groups were comparable in terms of age, race, and sex (P > .05). Subjects with HbSS exhibited lower median SpO 2 levels in the body and upper teeth, excluding canines, than subjects with HbAA (P  .05). Compared with individuals with HbAA, those with HbSS exhibited lower SpO 2 in maxillary teeth with confirmed pulp vitality, except in the canines. There was no correlation between SpO 2 levels of the body and dental pulp in individuals with HbSS or HbAA. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Nuclear Magnetic Resonance and Elastic Wave Velocity of Chalk Saturated with Brines Containing Divalent Ions

    DEFF Research Database (Denmark)

    Katika, Konstantina; Alam, Mohammad Monzurul; Fabricius, Ida Lykke

    divided into groups of three and each group was saturated either with deionized water, calcite equilibrated water, or sodium chloride, magnesium chloride and calcium chloride solutions of the same ionic strength. Saturation with solutions that contain divalent ions caused major shifts in the distribution...... of the relaxation time. Core samples saturated with calcium chloride solution relaxed slower and those saturated with magnesium chloride solution relaxed faster than the rest of the samples. Along with the changes in relaxation the samples experienced smaller velocities of elastic waves when saturated with MgCl2...

  9. [The effects of oxygen partial pressure changes on the osteometric markers of the bone tissue in rats].

    Science.gov (United States)

    Berezovs'kyĭ, V Ia; Zamors'ka, T M; Ianko, R V

    2013-01-01

    Our purpose was to investigate the oxygen partial pressure changes on the osteometric and biochemical markers of bone tissue in rats. It was shown that breathing of altered gas mixture did not change the mass, general length, sagittal diameter and density thigh-bones in 12-month Wistar male-rats. The dosed normobaric hypoxia increased the activity of alkaline phosphatase and decreased the activity of tartrate-resistant acid phosphatase. At the same time normobaric hyperoxia with 40 and 90% oxygen conversely decreased the activity of alkaline phosphatase and increased the activity of tartrate-resistant acid phosphatase.

  10. Speeding-up exchange-mediated saturation transfer experiments by Fourier transform

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Marta G.; Reddy, Jithender G.; Griesinger, Christian; Lee, Donghan, E-mail: dole@nmr.mpibpc.mpg.de [Max-Planck Institute for Biophysical chemistry, Department of NMR-based Structural Biology (Germany)

    2015-11-15

    Protein motions over various time scales are crucial for protein function. NMR relaxation dispersion experiments play a key role in explaining these motions. However, the study of slow conformational changes with lowly populated states remained elusive. The recently developed exchange-mediated saturation transfer experiments allow the detection and characterization of such motions, but require extensive measurement time. Here we show that, by making use of Fourier transform, the total acquisition time required to measure an exchange-mediated saturation transfer profile can be reduced by twofold in case that one applies linear prediction. In addition, we demonstrate that the analytical solution for R{sub 1}ρ experiments can be used for fitting the exchange-mediated saturation transfer profile. Furthermore, we show that simultaneous analysis of exchange-mediated saturation transfer profiles with two different radio-frequency field strengths is required for accurate and precise characterization of the exchange process and the exchanging states.

  11. Speeding-up exchange-mediated saturation transfer experiments by Fourier transform

    International Nuclear Information System (INIS)

    Carneiro, Marta G.; Reddy, Jithender G.; Griesinger, Christian; Lee, Donghan

    2015-01-01

    Protein motions over various time scales are crucial for protein function. NMR relaxation dispersion experiments play a key role in explaining these motions. However, the study of slow conformational changes with lowly populated states remained elusive. The recently developed exchange-mediated saturation transfer experiments allow the detection and characterization of such motions, but require extensive measurement time. Here we show that, by making use of Fourier transform, the total acquisition time required to measure an exchange-mediated saturation transfer profile can be reduced by twofold in case that one applies linear prediction. In addition, we demonstrate that the analytical solution for R 1 ρ experiments can be used for fitting the exchange-mediated saturation transfer profile. Furthermore, we show that simultaneous analysis of exchange-mediated saturation transfer profiles with two different radio-frequency field strengths is required for accurate and precise characterization of the exchange process and the exchanging states

  12. Regime shifts and ecological catastrophes in a model of plankton-oxygen dynamics under the climate change.

    Science.gov (United States)

    Petrovskii, Sergei; Sekerci, Yadigar; Venturino, Ezio

    2017-07-07

    It is estimated that more than a half of the total atmospheric oxygen is produced in the oceans due to the photosynthetic activity of phytoplankton. Any significant decrease in the net oxygen production by phytoplankton is therefore likely to result in the depletion of atmospheric oxygen and in a global mass mortality of animals and humans. In its turn, the rate of oxygen production is known to depend on water temperature and hence can be affected by the global warming. We address this problem theoretically by considering a model of a coupled plankton-oxygen dynamics where the rate of oxygen production slowly changes with time to account for the ocean warming. We show that, when the temperature rises sufficiently high, a regime shift happens: the sustainable oxygen production becomes impossible and the system's dynamics leads to fast oxygen depletion and plankton extinction. We also consider a scenario when, after a certain period of increase, the temperature is set on a new higher yet apparently safe value, i.e. before the oxygen depletion disaster happens. We show that in this case the system dynamics may exhibit a long-term quasi-sustainable dynamics that can still result in an ecological disaster (oxygen depletion and mass extinctions) but only after a considerable period of time. Finally, we discuss the early warning signals of the approaching regime shift resulting in the disaster. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Inelastic neutron scattering reactions in fluid saturated rock as exploited in oil well logging

    International Nuclear Information System (INIS)

    Underwood, M.C.; Dyos, C.J.

    1986-01-01

    Oil saturated sandstone and limestone targets have been irradiated with 14 MeV neutrons. Gamma-ray spectra were accumulated and the γ-ray intensities arising from inelastic neutron scattering reactions upon carbon and oxygen measured. The results are compared with the predictions of a simple model. They enable some features of the response of (n,γ) tools used in oil well logging to be established and current uncertainties in understanding to be highlighted. (author)

  14. Myocardial oxygenation and transmural lactate metabolism during experimental acute coronary stenosis in pigs.

    Science.gov (United States)

    Gonschior, P; Gonschior, G M; Conzen, P F; Hobbhahn, J; Goetz, A E; Peter, K; Brendel, W

    1992-01-01

    Measurement of surface tissue pO2 (ptO2) with surface electrodes is increasingly applied in experimental medicine. Its use on the beating heart may seem to be problematic because transmural gradients of tissue pO2 would reduce the validity of pO2 determinations in the epicardial layers. This study attempted to determine whether ptO2 may be a valid and sensitive indicator of transmural myocardial oxygenation. In order to measure ptO2, two eight-channel Clark-type electrodes were placed on a beating porcine left ventricle (n = 13). Measurements were made at different degrees of acute stenosis of the left anterior descending artery (LAD). A 24-F cannula was inserted into the great cardiac vein, draining the poststenotic myocardium to obtain coronary venous blood samples. Transmural metabolic changes were detected simultaneously by coronary venous blood gas parameters and lactate levels. Epicardial tissue pO2 was 49 +/- 2 mm Hg (mean +/- SEM) before stenosis and decreased to a mean value of 25 +/- 2 mm Hg during stenosis. Different degrees of LAD stenosis (ptO2 range: 12-35 mm Hg) were substantial enough to alter arterio-coronary venous lactate difference (avd lactate) from +0.31 +/- 0.07 mmol/l (control) to -0.62 +/- 0.15 mmol/l (stenosis). A significant linear correlation between changes of ptO2 (delta ptO2) and changes of avd lactate (delta avd lactate) resulted (y = 0.59 + 0.62x; r = 0.86; p less than or equal to 0.001). However, linear regression analysis between delta ptO2 correlated with the corresponding data from coronary venous pO2 (delta pO2cv) oxygen content (delta O2contcv), and oxygen saturation (delta O2satcv) showed no significant correlations. We conclude that measurement of ptO2 is a sensitive and valuable indicator of transmural oxygenation in ischemic myocardium, whereas pO2cv, O2contcv and O2satcv do not seem to be valid predictors of ischemia in myocardial oxygenation.

  15. Reinforcement corrosion in alkaline chloride media with reduced oxygen concentrations

    International Nuclear Information System (INIS)

    Andrade, C.; Fullea, J.; Toro, L.; Martinez, I.; Rebolledo, N.

    2013-01-01

    It is commonly considered that the corrosion of steel in concrete is controlled by the oxygen content of the pore solution and there are service life models that relate the corrosion rate to the amount of oxygen. It is also commonly believed that in water saturated conditions the oxygen content in the pores is negligible and that underwater there is no risk of depassivation and the corrosion rate is very low. However, the available data on corrosion rates in immersed conditions do not indicate such performance; on the contrary corrosion develops when sufficient chloride reaches the reinforcement. In the present paper, results are presented for tests performed in alkaline chloride solutions that were purged with nitrogen to reduce the oxygen content. The results indicate that at very low oxygen concentrations, corrosion may develop in the presence of chlorides. The presence or absence of corrosion is influenced by the amount of chloride, the corrosion potential and the steel surface condition. (authors)

  16. Changes induced in spice paprika powder by treatment with ionizing radiation and saturated steam[Food conservation; Spice paprika; Rheology; Colorimetry; Free radicals

    Energy Technology Data Exchange (ETDEWEB)

    Kispeter, J. E-mail: kispeter@szef.u-szeged.hu; Bajusz-Kabok, K.; Fekete, M.; Szabo, G.; Fodor, E.; Pali, T. E-mail: tpali@nucleus.szbk.u-szeged.hu

    2003-12-01

    The changes in spice paprika powder induced by ionizing radiation, saturated steam (SS) and their combination were studied as a function of the absorbed radiation dose and the storage time. The SS treatment lead to a decrease in color content (lightening) after 12 weeks of storage, together with the persistence of free radicals and viscosity changes for a longer period. The results suggest that ionizing radiation is a more advantageous method as concerns preservation of the quality of spice paprika.

  17. Repulsion-based model for contact angle saturation in electrowetting.

    Science.gov (United States)

    Ali, Hassan Abdelmoumen Abdellah; Mohamed, Hany Ahmed; Abdelgawad, Mohamed

    2015-01-01

    We introduce a new model for contact angle saturation phenomenon in electrowetting on dielectric systems. This new model attributes contact angle saturation to repulsion between trapped charges on the cap and base surfaces of the droplet in the vicinity of the three-phase contact line, which prevents these surfaces from converging during contact angle reduction. This repulsion-based saturation is similar to repulsion between charges accumulated on the surfaces of conducting droplets which causes the well known Coulombic fission and Taylor cone formation phenomena. In our model, both the droplet and dielectric coating were treated as lossy dielectric media (i.e., having finite electrical conductivities and permittivities) contrary to the more common assumption of a perfectly conducting droplet and perfectly insulating dielectric. We used theoretical analysis and numerical simulations to find actual charge distribution on droplet surface, calculate repulsion energy, and minimize energy of the total system as a function of droplet contact angle. Resulting saturation curves were in good agreement with previously reported experimental results. We used this proposed model to predict effect of changing liquid properties, such as electrical conductivity, and system parameters, such as thickness of the dielectric layer, on the saturation angle, which also matched experimental results.

  18. Solubility of oxygen in liquid sodium: effect on interpretation of corrosion data

    International Nuclear Information System (INIS)

    Claxton, K.T.

    1976-01-01

    No solubility correlation relating the equilibrium oxygen concentration with the sodium saturation temperature has yet been derived which has gained general acceptance. A statistical analysis of all the available data which directly or indirectly may be taken as representing a measurement of solubility has been made. The results indicate that a real and seemingly permanent difference is apparent between the assumed equilibrium levels of oxygen measured at different saturation temperatures as reported by UK and US workers. Data analysis procedures producing sub-sets of culled data which are then used to derive a compromise solubility function are considered less than adequate. It is considered preferable and more realistic to distinguish data sub-sets by the analytical technique employed. The established vacuum distillation method is shown to yield results differing among themselves by up to a factor of four at cold trap temperatures of relevance to fast reactor operation. The vanadium wire and electrochemical cell techniques are shown to give the lowest solubility values. Appropriate factors relating UK oxygen levels to values derived from alternative methods are presented. The divergent positions prevailing for oxygen-in-sodium analysis can lead to apparent anomalies when comparisons of corrosion rates from different sources have to be made. It is shown that this situation is, in part, apparently resolved by effecting comparisons at the equivalent cold trap temperature instead of the equivalent oxygen level. It is recognised that the approach presumes equilibrium of the oxygen in the sodium with the cold trap and reference is made to alternative ''sinks'' for oxygen. It is demonstrated, by comparison of a number of recommended and observed corrosion rates from US and European sources, that, in spite of the above and other qualifications, the approach is reasonable

  19. Circulation, eddies, oxygen, and nutrient changes in the eastern tropical South Pacific Ocean

    Science.gov (United States)

    Czeschel, R.; Stramma, L.; Weller, R. A.; Fischer, T.

    2015-06-01

    A large subsurface oxygen deficiency zone is located in the eastern tropical South Pacific Ocean (ETSP). The large-scale circulation in the eastern equatorial Pacific and off the coast of Peru in November/December 2012 shows the influence of the equatorial current system, the eastern boundary currents, and the northern reaches of the subtropical gyre. In November 2012 the equatorial undercurrent (EUC) is centered at 250 m depth, deeper than in earlier observations. In December 2012, the equatorial water is transported southeastward near the shelf in the Peru-Chile undercurrent (PCUC) with a mean transport of 1.4 Sv. In the oxygen minimum zone (OMZ), the flow is overlaid with strong eddy activity on the poleward side of the OMZ. Floats with parking depth at 400 m show fast westward flow in the mid-depth equatorial channel and sluggish flow in the OMZ. Floats with oxygen sensors clearly show the passage of eddies with oxygen anomalies. The long-term float observations in the upper ocean lead to a net community production estimate at about 18° S of up to 16.7 mmol C m-3 yr-1 extrapolated to an annual rate and 7.7 mmol C m-3 yr-1 for the time period below the mixed layer. Oxygen differences between repeated ship sections are influenced by the Interdecadal Pacific Oscillation (IPO), by the phase of El Niño, by seasonal changes, and by eddies, and hence have to be interpreted with care. At and south of the Equator the decrease in oxygen in the upper ocean since 1976 is related to an increase in nitrate, phosphate, and in part silicate.

  20. Hypercapnic Acidosis Preserves Gastric Mucosal Microvascular Oxygen Saturation in a Canine Model of Hemorrhage.

    NARCIS (Netherlands)

    Schwartges, Ingo; Picker, Olaf; Beck, Christopher; Scheeren, Thomas W. L.; Schwarte, Lothar A.

    2010-01-01

    The authors aimed to clarify the effects of hypercapnic acidosis and its timing on gastric mucosal oxygenation in a canine model of hemorrhage. This was designed as a prospective, controlled, randomized animal study set in a university research laboratory. Five chronically instrumented dogs were

  1. Effects of carvedilol and propranolol on circulatory regulation and oxygenation in cirrhosis

    DEFF Research Database (Denmark)

    Hobolth, Lise; Bendtsen, Flemming; Hansen, Erik F

    2014-01-01

    =16) or propranolol (n=13). Cardiac, systemic and splanchnic parameters along with oxygen saturation and plasma renin were measured at inclusion and after 3 months. RESULTS: Arterial blood pressure, heart rate, and cardiac output decreased equally, central circulation time and systemic vascular...... oxygen gradient remained constant in both groups. Hepatic venous pressure gradient decreased equally in the carvedilol and propranolol groups (-17% and -20%, non significant). CONCLUSIONS: Systemic haemodynamics and pulmonary effects of carvedilol and propranolol are modest and this study could...

  2. The role of central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference as a goal and prognosis of sepsis treatment.

    Science.gov (United States)

    Wittayachamnankul, Borwon; Chentanakij, Boriboon; Sruamsiri, Kamphee; Chattipakorn, Nipon

    2016-12-01

    The current practice in treatment of severe sepsis and septic shock is to ensure adequate oxygenation and perfusion in patients, along with prompt administration of antibiotics, within 6 hours from diagnosis, which is considered the "golden hour" for the patients. One of the goals of treatment is to restore normal tissue perfusion. With this goal in mind, some parameters have been used to determine the success of treatment and mortality rate; however, none has been proven to be the best predictor of mortality rate in sepsis patients. Despite growing evidence regarding the prognostic indicators for mortality in sepsis patients, inconsistent reports exist. This review comprehensively summarizes the reports regarding the frequently used parameters in sepsis including central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference, as prognostic indicators for clinical outcomes in sepsis patients. Moreover, consistent findings and inconsistent reports for their pathophysiology and the potential mechanisms for their use as well as their limitations in sepsis patients are presented and discussed. Finally, a schematic strategy for potential management and benefits in sepsis patients is proposed based upon these current available data. There is currently no ideal biomarker that can indicate prognosis, predict progression of the disease, and guide treatment in sepsis. Further studies are needed to be carried out to identify the ideal biomarker that has all the desired properties. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Effect of the surface oxygen groups on methane adsorption on coals

    Energy Technology Data Exchange (ETDEWEB)

    Hao Shixiong [Department of Chemical Engineering, Sichuan University, Chengdu 610065 (China); Department of Chemical Engineering, Sichuan University of Science and Engineering, Zigong 643000 (China); Wen Jie [Department of Chemical Engineering, Sichuan University, Chengdu 610065 (China); Yu Xiaopeng [Department of Chemical Engineering, Sichuan University, Chengdu 610065 (China); Department of Chemical Engineering, Sichuan University of Science and Engineering, Zigong 643000 (China); Chu Wei, E-mail: chuwei1965_scu@yahoo.com [Department of Chemical Engineering, Sichuan University, Chengdu 610065 (China)

    2013-01-01

    Highlights: Black-Right-Pointing-Pointer We modified one coal with H{sub 2}O{sub 2}, (NH{sub 4}){sub 2}S{sub 2}O{sub 8} and HNO{sub 3} respectively, to prepare coal samples with different surface properties. Black-Right-Pointing-Pointer The oxygen groups on coal surface were characterized by XPS. Black-Right-Pointing-Pointer The textures of the coal samples were investigated by N{sub 2} adsorption at 77 K. Black-Right-Pointing-Pointer The adsorption behaviors were measured by volumetric method. Black-Right-Pointing-Pointer There was a negative correlation between methane saturated adsorption capacity and the O{sub total}/C{sub total}. - Abstract: To investigate the influence of surface oxygen groups on methane adsorption on coals, one bituminous coal was modified with H{sub 2}O{sub 2}, (NH{sub 4}){sub 2}S{sub 2}O{sub 8} and HNO{sub 3} respectively, to prepare coal samples with different surface properties. The oxygen groups on coal surface were characterized by X-ray photoelectron spectroscopy (XPS). The textures of the coal samples were investigated by N{sub 2} adsorption at 77 K. Their surface morphologies were analyzed by scanning electron microscopy (SEM). The methane adsorption behaviors of these coal samples were measured at 303 K in pressure range of 0-5.3 MPa by volumetric method. The adsorption data of methane were fitted to the Langmuir model and Dubinin-Astakhov (D-A) model. The fitting results showed that the D-A model fitted the isotherm data better than the Langmuir model. It was observed that there was, in general, a positive correlation between the methane saturated adsorption capacity and the micropore volume of coals while a negative correlation between methane saturated adsorption capacity and the O{sub total}/C{sub total}. The methane adsorption capacity was determined by the coal surface chemistry when the microporosity parameters of two samples were similar. Coal with a higher amount of oxygen surface groups, and consequently with a less

  4. Ocean (de)oxygenation from the Last Glacial Maximum to the twenty-first century: insights from Earth System models

    Science.gov (United States)

    Bopp, L.; Resplandy, L.; Untersee, A.; Le Mezo, P.; Kageyama, M.

    2017-08-01

    All Earth System models project a consistent decrease in the oxygen content of oceans for the coming decades because of ocean warming, reduced ventilation and increased stratification. But large uncertainties for these future projections of ocean deoxygenation remain for the subsurface tropical oceans where the major oxygen minimum zones are located. Here, we combine global warming projections, model-based estimates of natural short-term variability, as well as data and model estimates of the Last Glacial Maximum (LGM) ocean oxygenation to gain some insights into the major mechanisms of oxygenation changes across these different time scales. We show that the primary uncertainty on future ocean deoxygenation in the subsurface tropical oceans is in fact controlled by a robust compensation between decreasing oxygen saturation (O2sat) due to warming and decreasing apparent oxygen utilization (AOU) due to increased ventilation of the corresponding water masses. Modelled short-term natural variability in subsurface oxygen levels also reveals a compensation between O2sat and AOU, controlled by the latter. Finally, using a model simulation of the LGM, reproducing data-based reconstructions of past ocean (de)oxygenation, we show that the deoxygenation trend of the subsurface ocean during deglaciation was controlled by a combination of warming-induced decreasing O2sat and increasing AOU driven by a reduced ventilation of tropical subsurface waters. This article is part of the themed issue 'Ocean ventilation and deoxygenation in a warming world'.

  5. Ocean (de)oxygenation from the Last Glacial Maximum to the twenty-first century: insights from Earth System models.

    Science.gov (United States)

    Bopp, L; Resplandy, L; Untersee, A; Le Mezo, P; Kageyama, M

    2017-09-13

    All Earth System models project a consistent decrease in the oxygen content of oceans for the coming decades because of ocean warming, reduced ventilation and increased stratification. But large uncertainties for these future projections of ocean deoxygenation remain for the subsurface tropical oceans where the major oxygen minimum zones are located. Here, we combine global warming projections, model-based estimates of natural short-term variability, as well as data and model estimates of the Last Glacial Maximum (LGM) ocean oxygenation to gain some insights into the major mechanisms of oxygenation changes across these different time scales. We show that the primary uncertainty on future ocean deoxygenation in the subsurface tropical oceans is in fact controlled by a robust compensation between decreasing oxygen saturation (O 2sat ) due to warming and decreasing apparent oxygen utilization (AOU) due to increased ventilation of the corresponding water masses. Modelled short-term natural variability in subsurface oxygen levels also reveals a compensation between O 2sat and AOU, controlled by the latter. Finally, using a model simulation of the LGM, reproducing data-based reconstructions of past ocean (de)oxygenation, we show that the deoxygenation trend of the subsurface ocean during deglaciation was controlled by a combination of warming-induced decreasing O 2sat and increasing AOU driven by a reduced ventilation of tropical subsurface waters.This article is part of the themed issue 'Ocean ventilation and deoxygenation in a warming world'. © 2017 The Author(s).

  6. The impact of including spatially longitudinal heterogeneities of vessel oxygen content and vascular fraction in 3D tumor oxygenation models on predicted radiation sensitivity.

    Science.gov (United States)

    Lagerlöf, Jakob H; Kindblom, Jon; Bernhardt, Peter

    2014-04-01

    Oxygen distribution models have been used to analyze the influences of oxygen tensions on tissue response after radiotherapy. These distributions are often generated assuming constant oxygen tension in the blood vessels. However, as red blood cells progress through the vessels, oxygen is continuously released into the plasma and the surrounding tissue, resulting in longitudinally varying oxygen levels in the blood vessels. In the present study, the authors investigated whether a tumor oxygenation model that incorporated longitudinally varying oxygen levels would provide different predictions of necrotic fractions and radiosensitivity compared to commonly used models with a constant oxygen pressure. Our models simulated oxygen diffusion based on a Green's function approach and oxygen consumption according to the Michaelis-Menten equation. The authors constructed tumor models with different vascular fractions (VFs), from which they generated depth oxygenation curves and a look-up table of oxygen pressure gradients. The authors evaluated models of spherical tumors of various sizes, from 1 to 10(4) mg. The authors compared the results from a model with constant vessel oxygen (CVO) pressure to those from models with longitudinal variations in oxygen saturation and either a constant VF (CVF) or variable VF (VVF) within the tumor tissue. The authors monitored the necrotic fractions, defined as tumor regions with an oxygen pressure below 1 mmHg. Tumor radiation sensitivity was expressed as D99, the homogeneous radiation dose required for a tumor control probability of 0.99. In the CVO saturation model, no necrosis was observed, and decreasing the VF could only decrease the D99 by up to 10%. Furthermore, the D99 vs VF dependence was similar for different tumor masses. Compared to the CVO model, the extended CVF and VVF models provided clearly different results, including pronounced effects of VF and tumor size on the necrotic fraction and D99, necrotic fractions ranging

  7. Muscle oxygen changes following Sprint Interval Cycling training in elite field hockey players.

    Directory of Open Access Journals (Sweden)

    Ben Jones

    Full Text Available This study examined the effects of Sprint Interval Cycling (SIT on muscle oxygenation kinetics and performance during the 30-15 intermittent fitness test (IFT. Twenty-five women hockey players of Olympic standard were randomly selected into an experimental group (EXP and a control group (CON. The EXP group performed six additional SIT sessions over six weeks in addition to their normal training program. To explore the potential training-induced change, EXP subjects additionally completed 5 x 30s maximal intensity cycle testing before and after training. During these tests near-infrared spectroscopy (NIRS measured parameters; oxyhaemoglobin + oxymyoglobin (HbO2+ MbO2, tissue deoxyhaemoglobin + deoxymyoglobin (HHb+HMb, total tissue haemoglobin (tHb and tissue oxygenation (TSI % were taken. In the EXP group (5.34 ± 0.14 to 5.50 ± 0.14 m.s(-1 but not the CON group (pre = 5.37 ± 0.27 to 5.39 ± 0.30 m.s(-1 significant changes were seen in the 30-15 IFT performance. EXP group also displayed significant post-training increases during the sprint cycling: ΔTSI (-7.59 ± 0.91 to -12.16 ± 2.70%; ΔHHb+HMb (35.68 ± 6.67 to 69.44 ± 26.48 μM.cm; and ΔHbO2+ MbO2 (-74.29 ± 13.82 to -109.36 ± 22.61 μM.cm. No significant differences were seen in ΔtHb (-45.81 ± 15.23 to -42.93 ± 16.24. NIRS is able to detect positive peripheral muscle oxygenation changes when used during a SIT protocol which has been shown to be an effective training modality within elite athletes.

  8. Somatosensory evoked changes in cerebral oxygen consumption measured non-invasively in premature neonates

    Science.gov (United States)

    Roche-Labarbe, Nadege; Fenoglio, Angela; Radakrishnan, Harsha; Kocienski-Filip, Marcia; Carp, Stefan A.; Dubb, Jay; Boas, David A.; Grant, P. Ellen; Franceschini, Maria Angela

    2013-01-01

    The hemodynamic functional response is used as a reliable marker of neuronal activity in countless studies of brain function and cognition. In newborns and infants, however, conflicting results have appeared in the literature concerning the typical response, and there is little information on brain metabolism and functional activation. Measurement of all hemodynamic components and oxygen metabolism is critical for understanding neurovascular coupling in the developing brain. To this end, we combined multiple near infrared spectroscopy techniques to measure oxy- and deoxy-hemoglobin concentrations, cerebral blood volume (CBV), and relative cerebral blood flow (CBF) in the somatosensory cortex of 6 preterm neonates during passive tactile stimulation of the hand. By combining these measures we estimated relative changes in the cerebral metabolic rate of oxygen consumption (rCMRO2). CBF starts increasing immediately after stimulus onset, and returns to baseline before blood volume. This is consistent with the model of pre-capillary arteriole active dilation driving the CBF response, with a subsequent CBV increase influenced by capillaries and veins dilating passively to accommodate the extra blood. rCMRO2 estimated using the steady-state formulation shows a biphasic pattern: an increase immediately after stimulus onset, followed by a post-stimulus undershoot due to blood flow returning faster to baseline than oxygenation. However, assuming a longer mean transit time from the arterial to the venous compartment, due to the immature vascular system of premature infants, reduces the post-stimulus undershoot and increases the flow/consumption ratio to values closer to adult values reported in the literature. We are the first to report changes in local rCBF and rCMRO2 during functional activation in preterm infants. The ability to measure these variables in addition to hemoglobin concentration changes is critical for understanding neurovascular coupling in the developing

  9. The Danish tax on saturated fat

    DEFF Research Database (Denmark)

    Vallgårda, Signild; Holm, Lotte; Jensen, Jørgen Dejgård

    2015-01-01

    arguments and themes involved in the debates surrounding the introduction and the repeal. SUBJECTS/METHODS: An analysis of parliamentary debates, expert reports and media coverage; key informant interviews; and a review of studies about the effects of the tax on consumer behaviour. RESULTS: A tax......BACKGROUND/OBJECTIVES: Health promoters have repeatedly proposed using economic policy tools, taxes and subsidies, as a means of changing consumer behaviour. As the first country in the world, Denmark introduced a tax on saturated fat in 2011. It was repealed in 2012. In this paper, we present...... indicates that the tax was effective in changing consumer behaviour....

  10. A methodology to calibrate water saturation estimated from 4D seismic data

    International Nuclear Information System (INIS)

    Davolio, Alessandra; Maschio, Célio; José Schiozer, Denis

    2014-01-01

    Time-lapse seismic data can be used to estimate saturation changes within a reservoir, which is valuable information for reservoir management as it plays an important role in updating reservoir simulation models. The process of updating reservoir properties, history matching, can incorporate estimated saturation changes qualitatively or quantitatively. For quantitative approaches, reliable information from 4D seismic data is important. This work proposes a methodology to calibrate the volume of water in the estimated saturation maps, as these maps can be wrongly estimated due to problems with seismic signals (such as noise, errors associated with data processing and resolution issues). The idea is to condition the 4D seismic data to known information provided by engineering, in this case the known amount of injected and produced water in the field. The application of the proposed methodology in an inversion process (previously published) that estimates saturation from 4D seismic data is presented, followed by a discussion concerning the use of such data in a history matching process. The methodology is applied to a synthetic dataset to validate the results, the main of which are: (1) reduction of the effects of noise and errors in the estimated saturation, yielding more reliable data to be used quantitatively or qualitatively and (2) an improvement in the properties update after using this data in a history matching procedure. (paper)

  11. Functional magnetic resonance imaging (fMRI) for fetal oxygenation during maternal hypoxia: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Wedegaertner, U.; Adam, G. [Abt. fuer Diagnostische und Interventionelle Radiologie, Klinik und Poliklinik fuer Radiologie, UKE Hamburg (Germany); Tchirikov, M.; Schroeder, H. [Abt. fuer experimentelle Gynaekologie der Universitaetsfrauenklinik, Klinik und Poliklinik fuer Frauenheilkunde, UKE, Hamburg (Germany); Koch, M. [Klinik und Poliklinik fuer Neurologie, UKE Hamburg (Germany)

    2002-06-01

    Purpose: To investigate the potential of fMRI to measure changes in fetal tissue oxygenation during acute maternal hypoxia in fetal lambs. Material and Methods: Two ewes carrying singleton fetuses (gestational age 125 and 131 days) underwent MR imaging under inhalation anesthesia. BOLD imaging of the fetal brain, liver and myocardium was performed during acute maternal hypoxia (oxygen replaced by N{sub 2}O). Maternal oxygen saturation and heart rate were monitored by a pulse-oxymeter attached to the maternal tongue. Results: Changes of fetal tissue oxygenation during maternal hypoxia were clearly visible with BOLD MRI. Signal intensity decreases were more distinct in liver and heart ({proportional_to}40%) from control than in the fetal brain ({proportional_to}10%). Conclusions: fMRI is a promising diagnostic tool to determine fetal tissue oxygenation and may open new opportunities in monitoring fetal well being in high risk pregnancies complicated by uteroplacentar insufficiency. Different signal changes in liver/heart and brain may reflect a centralization of the fetal blood flow. (orig.) [German] Ziel: Untersuchung des Potentiales der funktionellen MRT (BOLD) in der Darstellung von Veraenderungen in der Sauerstoffsaettigung fetaler Gewebe waehrend akuter materner Hypoxie bei fetalen Laemmern. Material und Methoden: Die MR-Untersuchung wurde an zwei Mutterschafen mit 125 und 131 Tage alten Feten in Inhalationsnarkose durchgefuehrt. Die BOLD Messungen von fetaler Leber, Myokard und Gehirn erfolgten waehrend einer akuten Hypoxiephase des Muttertieres, in der Sauerstoff durch N{sub 2}O ersetzt wurde. Die materne Sauerstoffsaettigung und Herzfrequenz wurde durch ein Pulsoxymeter ueberwacht. Ergebnisse: Aenderungen der fetalen Gewebsoxygenierung waehrend einer akuten Hypoxiephase der Mutter waren mit der BOLD-MR-Bildgebung deutlich darstellbar. In der fetalen Leber und dem Myokard zeigte sich ein staerkerer Signalabfall um ca. 40% von den Kontrollwerten als im fetalen

  12. Effects of noninvasive ventilation on sleep outcomes in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Katzberg, Hans D; Selegiman, Adam; Guion, Lee; Yuan, Nancy; Cho, Sungho C; Katz, Jonathan S; Miller, Robert G; So, Yuen T

    2013-04-15

    The objective was to study the effects on noninvasive ventilation on sleep outcomes in patient with ALS, specifically oxygenation and overall sleep quality. Patients with ALS who met criteria for initiation of NIV were studied with a series of 2 home PSG studies, one without NIV and a follow-up study while using NIV. Primary outcome was a change in the maximum overnight oxygen saturation; secondary outcomes included change in mean overnight oxygen saturation, apnea and hypopnea indexes, sleep latency, sleep efficiency, sleep arousals, and sleep architecture. A total of 94 patients with ALS were screened for eligibility; 15 were enrolled; and 12 completed study procedures. Maximum overnight oxygen saturation improved by 7.0% (p = 0.01) and by 6.7% during REM sleep (p = 0.02) with NIV. Time spent below 90% oxygen saturation was also significant-ly better with NIV (30% vs 19%, p NIV. NIV had no effect on sleep efficiency (mean change 10%), arousal index (7 to 12), or sleep stage distribution (Friedman chi-squared = 0.40). NIV improved oxygenation but showed no significant effects on sleep efficiency, sleep arousals, restful sleep, or sleep architecture. The net impact of these changes for patients deserves further study in a larger group of ALS patients.

  13. Changes in iron levels, total iron binding capacity, transferrin saturation in race horses, before and after of physical exercise

    Directory of Open Access Journals (Sweden)

    Gláucia Abramovitc

    2014-09-01

    Full Text Available ABSTRACT. Abramovitc G., Parra A.C. & Fernandes W.R. [Changes in iron levels, total iron binding capacity, transferrin saturation in race horses, before and after of physical exercise]. Variação de níveis séricos de ferro, da capacidade total de ligação do ferro e da saturação da transferrina em equinos de corrida, antes e após exercício físico. Revista Brasileira de Medicina Veterinária, 36(3:289-293, 2014. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Rua Prof. Dr. Orlando Marques de Paiva 87, Cidade Universitária, Butantã, São Paulo, SP 05508-270, Brasil. Email: wilsonrf@usp.br The preparation of the horse for physical activities in competition is directly related to important factors such as nutrition, muscle adaptation and blood profile, related to the concentration of serum iron, total capacity total iron binding capacity (TIBC and saturation of transferrin. This study aimed to evaluate the influence of exercise in iron levels, the total iron and transferrin saturation in race horses. One hundred and eleven samples of blood serum were collected from Thoroughbred horses, from the Jockey Club of São Paulo, aged between 3 and 4 years old, male and female, clinically healthy, practitioners turf competition, in sand or grass. The samples were obtained before exercise (control time and 30 minutes after exercise (post exercise. These animals were submitted to gallop training, of high intensity and short duration for this research. As a result, it was observed that the serum concentration of iron (Fe showed a statistically significant lowering post-exercise, due to organic re-balance of iron, while TIBC (total iron binding capacity showed a clear and significant increase in their serum levels due to increased needs of iron during and after exercise. The percentage of transferrin saturation in serum was shown to be lower post-exercise, probably due to the recruitment of

  14. Determination of relative CMRO2 from CBF and BOLD changes: significant increase of oxygen consumption rate during visual stimulation

    DEFF Research Database (Denmark)

    Kim, S.G.; Rostrup, Egill; Larsson, H.B.

    1999-01-01

    signal changes were measured simultaneously using the flow-sensitive alternating inversion recovery (FAIR) technique. During hypercapnia established by an end-tidal CO2 increase of 1.46 kPa, CBF in the visual cortex increased by 47.3 +/- 17.3% (mean +/- SD; n = 9), and deltaR2* was -0.478 +/- 0.147 sec......The blood oxygenation level-dependent (BOLD) effect in functional magnetic resonance imaging depends on at least partial uncoupling between cerebral blood flow (CBF) and cerebral metabolic rate of oxygen (CMRO2) changes. By measuring CBF and BOLD simultaneously, the relative change in CMRO2 can...

  15. Outcomes of acute exacerbations in COPD in relation to pre-hospital oxygen therapy

    DEFF Research Database (Denmark)

    Ringbaek, Thomas J; Terkelsen, Jakob; Lange, Peter

    2015-01-01

    . METHODS: In an audit of 405 consecutive patients with AECOPD arriving by ambulance to Hvidovre Hospital, details of transit time, oxygen administration, saturation, and arterial blood gases were registered. Outcomes were respiratory acidosis, need of supported ventilation, length of hospitalisation......' (saturation ≥92%) had a high frequency of respiratory acidosis at hospital admission, 108 (33.5%) of 324 patients, length of stay was on average 5.1 days, 12.5% of the patients needed ventilatory support, and in-hospital mortality was 3.4%. CONCLUSION: The majority of patients with AECOPD received...

  16. Cerebral and Renal Oxygen Saturation Are Not Compromised in the Presence of Retrograde Blood Flow in either the Ascending or Descending Aorta in Term or Near-Term Infants with Left-Sided Obstructive Lesions.

    Science.gov (United States)

    van der Laan, Michelle E; Mebius, Mirthe J; Roofthooft, Marcus T R; Bos, Arend F; Berger, Rolf M F; Kooi, Elisabeth M W

    2017-01-01

    In infants with left-sided obstructive lesions (LSOL), the presence of retrograde blood flow in either the ascending or descending aorta may lead to diminished cerebral and renal blood flow, respectively. Our aim was to compare cerebral and renal tissue oxygen saturation (rSO2) between infants with LSOL with antegrade and retrograde blood flow in the ascending aorta and with and without diastolic backflow in the descending aorta. Based on 2 echocardiograms, the study group was categorized according to the direction of blood flow in the ascending and descending aorta. We measured cerebral and renal rSO2 using near-infrared spectroscopy and calculated fractional tissue oxygen extraction (FTOE). Nineteen infants with LSOL, admitted to the NICU between 0 and 28 days after birth, were included. Infants with antegrade blood flow (n = 12) and infants with retrograde blood flow in the ascending aorta (n = 7) had similar cerebral rSO2 and FTOE during both echocardiograms. Only during the first echocardiogram, infants with retrograde blood flow in the ascending aorta had lower renal FTOE (0.14 vs. 0.32, p = 0.04) and tended to have higher renal rSO2 (80 vs. 65%, p = 0.09). The presence of diastolic backflow in the descending aorta was not associated with cerebral or renal rSO2 and FTOE during the first (n = 8) as well as the second echocardiogram (n = 10). Retrograde blood flow in the ascending aorta was not associated with cerebral oxygenation, while diastolic backflow in the descending aorta was not associated with renal oxygenation in infants with LSOL. © 2017 S. Karger AG, Basel.

  17. System Li2O-MoO3 as a catalyst of oxygen (air) electrode

    International Nuclear Information System (INIS)

    Gavdzik, A.; Gajda, S.; Sofronkov, A.

    2000-01-01

    Potential of electrode on the basis of system Li x Mo 2-x O 6 (x 0.1-0.5) in alkaline solution saturated by oxygen was studied by the method of polarization curves recording. It is ascertained that the value of stationary potential characteristic of the electrode described under the conditions mentioned is determined by reversible reaction between oxygen and water molecules, resulting in formation of hydroxyl and hydrogen peroxide anions. Practicability of using the solid solutions on the basis of molybdenum oxide with additions of lithium oxide as a catalyst of oxygen (air) electrode in electrochemical current sources is demonstrated [ru

  18. Oxygen requirements of separated hybrid catfish female Ictalurus punctatus male I. furcatus eggs

    Science.gov (United States)

    Channel catfish Ictalurus punctatus egg masses require ambient water with over 95% air saturation to maintain maximum oxygen consumption as they near hatch. Since hybrid catfish eggs (channel catfish ' X blue catfish I. furcatus ') are often kept separated after fertilization by the addition of full...

  19. Noninvasive in vivo optical characterization of blood flow and oxygen consumption in the superficial plexus of skin

    Science.gov (United States)

    Liasi, Faezeh Talebi; Samatham, Ravikant; Jacques, Steven L.

    2017-11-01

    Assessing the metabolic activity of a tissue, whether normal, damaged, aged, or pathologic, is useful for diagnosis and evaluating the effects of drugs. This report describes a handheld optical fiber probe that contacts the skin, applies pressure to blanch the superficial vascular plexus of the skin, then releases the pressure to allow refill of the plexus. The optical probe uses white light spectroscopy to record the time dynamics of blanching and refilling. The magnitude and dynamics of changes in blood content and hemoglobin oxygen saturation yield an estimate of the oxygen consumption rate (OCR) in units of attomoles per cell per second. The average value of OCR on nine forearm sites on five subjects was 10±5 (amol/cell/s). This low-cost, portable, rapid, noninvasive optical probe can characterize the OCR of a skin site to assess the metabolic activity of the epidermis or a superficial lesion.

  20. Experimental and numerical study on thermal conductivity of partially saturated unconsolidated sands

    Science.gov (United States)

    Lee, Youngmin; Keehm, Youngseuk; Kim, Seong-Kyun; Shin, Sang Ho

    2016-04-01

    A class of problems in heat flow applications requires an understanding of how water saturation affects thermal conductivity in the shallow subsurface. We conducted a series of experiments using a sand box to evaluate thermal conductivity (TC) of partially saturated unconsolidated sands under varying water saturation (Sw). We first saturated sands fully with water and varied water saturation by drainage through the bottom of the sand box. Five water-content sensors were integrated vertically into the sand box to monitor water saturation changes and a needle probe was embedded to measure thermal conductivity of partially saturated sands. The experimental result showed that thermal conductivity decreases from 2.5 W/mK for fully saturated sands to 0.7 W/mK when water saturation is 5%. We found that the decreasing trend is quite non-linear: highly sensitive at very high and low water saturations. However, the boundary effects on the top and the bottom of the sand box seemed to be responsible for this high nonlinearity. We also found that the determination of water saturation is quite important: the saturation by averaging values from all five sensors and that from the sensor at the center position, showed quite different trends in the TC-Sw domain. In parallel, we conducted a pore-scale numerical modeling, which consists of the steady-state two-phase Lattice-Boltzmann simulator and FEM thermal conduction simulator on digital pore geometry of sand aggregation. The simulation results showed a monotonous decreasing trend, and are reasonably well matched with experimental data when using average water saturations. We concluded that thermal conductivity would decrease smoothly as water saturation decreases if we can exclude boundary effects. However, in dynamic conditions, i.e. imbibition or drainage, the thermal conductivity might show hysteresis, which can be investigated with pore-scale numerical modeling with unsteady-state two-phase flow simulators in our future work.

  1. Double shock dynamics induced by the saturation of defocusing nonlinearities

    KAUST Repository

    Crosta, Matteo

    2012-01-01

    We show that the saturation of defocusing nonlinearities leads to qualitative changes in the onset of wave breaking, determining double shock formation whose regularization occurs in terms of antidark solitons. In a given material, the crossover between different regimes can be controlled by changing the input intensity. © 2012 Optical Society of America.

  2. Oxygen-doped Sb{sub 4}Te phase change films for high-temperature data retention and low-power application

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Yifeng [Functional Materials Research Laboratory, Tongji University, Shanghai 200092 (China); School of Mathematics and Physics, Jiangsu Teachers University of Technology, Changzhou 213001 (China); Sun, Mingcheng [Functional Materials Research Laboratory, Tongji University, Shanghai 200092 (China); Song, Sannian; Song, Zhitang [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Micro-System and Information Technology, Chinese Academy of Sciences, Shanghai 200050 (China); Zhai, Jiwei, E-mail: apzhai@tongji.edu.cn [Functional Materials Research Laboratory, Tongji University, Shanghai 200092 (China)

    2013-02-25

    Highlights: Black-Right-Pointing-Pointer O-doped Sb{sub 4}Te phase-change films were reported. Black-Right-Pointing-Pointer The amorphous-to-crystalline transitions of O-doped Sb{sub 4}Te films were studied. Black-Right-Pointing-Pointer By doping oxygen, the stability of Sb{sub 4}Te films is improved greatly. Black-Right-Pointing-Pointer The resistance of the Sb{sub 4}Te films increases by doping oxygen. - Abstract: The amorphous-to-crystalline transitions of oxygen-doped Sb{sub 4}Te (STO) films are investigated by in situ film resistance measurements. The crystalline temperature and resistance of the oxygen-doped films increase. The analysis of X-ray diffractomer (XRD) and X-ray photoelectron spectroscopy (XPS) indicate that the films with doping of a small amount of oxygen atoms can refine the grain size and form oxide, improving the resistance and thermal stability of phase change films. Excessive oxygen in Sb{sub 4}Te will make Te separate, resulting in deteriorating the stability. As a result, STO2 film has the relatively high activation energy for crystallization. The 10-year lifetime is raised from 29 Degree-Sign C of undoped Sb{sub 4}Te film to 102 Degree-Sign C of STO3 film. Phase transition from amorphous state to crystalline state is observed at relatively lower power, compared with a device using Ge{sub 2}Sb{sub 2}Te{sub 5} film.

  3. Iron saturation control in RHIC dipole magnets

    International Nuclear Information System (INIS)

    Thompson, P.A.; Gupta, R.C.; Kahn, S.A.; Hahn, H.; Morgan, G.H.; Wanderer, P.J.; Willen, E.

    1991-01-01

    The Relativistic Heavy Ion Collider (RHIC) will require 360 dipoles of 80 mm bore. This paper discusses the field perturbations produced by the saturation of the yoke iron. Changes have been made to the yoke to reduce these perturbations, in particular, decapole -4 . Measurements and calculations for 6 series of dipole magnets are presented. 2 refs., 2 figs., 1 tab

  4. Influence of Hypoxic Interval Training and Hyperoxic Recovery on Muscle Activation and Oxygenation in Connection with Double-Poling Exercise.

    Directory of Open Access Journals (Sweden)

    Christoph Zinner

    Full Text Available Here, we evaluated the influence of breathing oxygen at different partial pressures during recovery from exercise on performance at sea-level and a simulated altitude of 1800 m, as reflected in activation of different upper body muscles, and oxygenation of the m. triceps brachii. Ten well-trained, male endurance athletes (25.3±4.1 yrs; 179.2±4.5 cm; 74.2±3.4 kg performed four test trials, each involving three 3-min sessions on a double-poling ergometer with 3-min intervals of recovery. One trial was conducted entirely under normoxic (No and another under hypoxic conditions (Ho; FiO2 = 0.165. In the third and fourth trials, the exercise was performed in normoxia and hypoxia, respectively, with hyperoxic recovery (HOX; FiO2 = 1.00 in both cases. Arterial hemoglobin saturation was higher under the two HOX conditions than without HOX (p<0.05. Integrated muscle electrical activity was not influenced by the oxygen content (best d = 0.51. Furthermore, the only difference in tissue saturation index measured via near-infrared spectroscopy observed was between the recovery periods during the NoNo and HoHOX interventions (P<0.05, d = 0.93. In the case of HoHo the athletes' Pmean declined from the first to the third interval (P < 0.05, whereas Pmean was unaltered under the HoHOX, NoHOX and NoNo conditions. We conclude that the less pronounced decline in Pmean during 3 x 3-min double-poling sprints in normoxia and hypoxia with hyperoxic recovery is not related to changes in muscle activity or oxygenation. Moreover, we conclude that hyperoxia (FiO2 = 1.00 used in conjunction with hypoxic or normoxic work intervals may serve as an effective aid when inhaled during the subsequent recovery intervals.

  5. Design of a tissue oxygenation monitor and verification on human skin

    Science.gov (United States)

    Liu, Hongyuan; Kohl-Bareis, Matthias; Huang, Xiabing

    2011-07-01

    We report the design of a tissue oxygen and temperature monitor. The non-invasive, fibre based device monitors tissue haemoglobin (Hb) and oxygen saturation (SO2) and is based on white-light reflectance spectroscopy.Visible light with wavelengths in the 500 - 650nm range is utilized. The spectroscopic algorithm takes into account the tissue scattering and melanin absorption for the calculation of tissue haemoglobin concentration and oxygen saturation. The monitor can probe superficial layers of tissue with a high spatial resolution (mm3) and a high temporal resolution (40 Hz). It provides an accurate measurement with the accuracy of SO2 at 2 % and high reliability with less than 2 % variation of continuous SO2 measurement over 12 hours. It can also form a modular system when used in conjunction with a laser Doppler monitor, enabling simultaneous measurements of Hb, SO2 and blood flow. We found experimentally that the influence of the source-detector separation on the haemoglobin parameters is small. This finding is discussed by Monte Carlo simulations for the depth sensitivity profile. The influence of probe pressure and the skin pigmentation on the measurement parameters are assessed before in vivo experimental data is presented. The combination with laser Doppler flowmetry demonstrates the importance of a measurement of both the haemoglobin and the blood flow parameters for a full description of blood tissue perfusion. This is discussed in experimental data on human skin during cuff occlusion and after hyperemisation by a pharmacological cream. Strong correlation is observed between tissue oxygen (Hb and SO2) and blood flow measurements.

  6. Noninvasive detection of change in skeletal muscle oxygenation during incremental exercise with near-infrared spectroscopy

    Science.gov (United States)

    Liu, Fang; Luo, Qingming; Xu, Guodong; Li, Pengcheng

    2003-12-01

    Near infrared spectroscopy (NIRS) has been developed as a non-invasive method to assess O2 delivery, O2 consumption and blood flow, in diverse local muscle groups at rest and during exercise. The aim of this study was to investigate local O2 consumption in exercising muscle by use of near-infrared spectroscopy (NIRS). Ten elite athletes of different sport items were tested in rest and during step incremental load exercise. Local variations of quadriceps muscles were investigated with our wireless NIRS blood oxygen monitor system. The results show that the changes of blood oxygen relate on the sport items, type of muscle, kinetic capacity et al. These results indicate that NIRS is a potential useful tool to detect local muscle oxygenation and blood flow profiles; therefore it might be easily applied for evaluating the effect of athletes training.

  7. SATURATED ZONE IN-SITU TESTING

    Energy Technology Data Exchange (ETDEWEB)

    P.W. REIMUS

    2004-11-08

    The purpose of this scientific analysis is to document the results and interpretations of field experiments that test and validate conceptual flow and radionuclide transport models in the saturated zone (SZ) near Yucca Mountain, Nevada. The test interpretations provide estimates of flow and transport parameters used in the development of parameter distributions for total system performance assessment (TSPA) calculations. These parameter distributions are documented in ''Site-Scale Saturated Zone Flow Model (BSC 2004 [DIRS 170037]), Site-Scale Saturated Zone Transport'' (BSC 2004 [DIRS 170036]), Saturated Zone Colloid Transport (BSC 2004 [DIRS 170006]), and ''Saturated Zone Flow and Transport Model Abstraction'' (BSC 2004 [DIRS 170042]). Specifically, this scientific analysis contributes the following to the assessment of the capability of the SZ to serve as part of a natural barrier for waste isolation for the Yucca Mountain repository system: (1) The bases for selection of conceptual flow and transport models in the saturated volcanics and the saturated alluvium located near Yucca Mountain. (2) Results and interpretations of hydraulic and tracer tests conducted in saturated fractured volcanics at the C-wells complex near Yucca Mountain. The test interpretations include estimates of hydraulic conductivities, anisotropy in hydraulic conductivity, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, matrix diffusion coefficients, fracture apertures, and colloid transport parameters. (3) Results and interpretations of hydraulic and tracer tests conducted in saturated alluvium at the Alluvial Testing Complex (ATC) located at the southwestern corner of the Nevada Test Site (NTS). The test interpretations include estimates of hydraulic conductivities, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass

  8. SATURATED ZONE IN-SITU TESTING

    International Nuclear Information System (INIS)

    REIMUS, P.W.

    2004-01-01

    The purpose of this scientific analysis is to document the results and interpretations of field experiments that test and validate conceptual flow and radionuclide transport models in the saturated zone (SZ) near Yucca Mountain, Nevada. The test interpretations provide estimates of flow and transport parameters used in the development of parameter distributions for total system performance assessment (TSPA) calculations. These parameter distributions are documented in ''Site-Scale Saturated Zone Flow Model (BSC 2004 [DIRS 170037]), Site-Scale Saturated Zone Transport'' (BSC 2004 [DIRS 170036]), Saturated Zone Colloid Transport (BSC 2004 [DIRS 170006]), and ''Saturated Zone Flow and Transport Model Abstraction'' (BSC 2004 [DIRS 170042]). Specifically, this scientific analysis contributes the following to the assessment of the capability of the SZ to serve as part of a natural barrier for waste isolation for the Yucca Mountain repository system: (1) The bases for selection of conceptual flow and transport models in the saturated volcanics and the saturated alluvium located near Yucca Mountain. (2) Results and interpretations of hydraulic and tracer tests conducted in saturated fractured volcanics at the C-wells complex near Yucca Mountain. The test interpretations include estimates of hydraulic conductivities, anisotropy in hydraulic conductivity, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, matrix diffusion coefficients, fracture apertures, and colloid transport parameters. (3) Results and interpretations of hydraulic and tracer tests conducted in saturated alluvium at the Alluvial Testing Complex (ATC) located at the southwestern corner of the Nevada Test Site (NTS). The test interpretations include estimates of hydraulic conductivities, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, and colloid

  9. Automatic NAA. Saturation activities

    International Nuclear Information System (INIS)

    Westphal, G.P.; Grass, F.; Kuhnert, M.

    2008-01-01

    A system for Automatic NAA is based on a list of specific saturation activities determined for one irradiation position at a given neutron flux and a single detector geometry. Originally compiled from measurements of standard reference materials, the list may be extended also by the calculation of saturation activities from k 0 and Q 0 factors, and f and α values of the irradiation position. A systematic improvement of the SRM approach is currently being performed by pseudo-cyclic activation analysis, to reduce counting errors. From these measurements, the list of saturation activities is recalculated in an automatic procedure. (author)

  10. Electrochemical quartz crystal microbalance analysis of the oxygen reduction reaction on Pt-based electrodes. Part 2: adsorption of oxygen species and ClO4(-) anions on Pt and Pt-Co alloy in HClO4 solutions.

    Science.gov (United States)

    Omura, J; Yano, H; Tryk, D A; Watanabe, M; Uchida, H

    2014-01-14

    To gain deeper insight into the role of adsorbed oxygenated species in the O2 reduction reaction (ORR) kinetics on platinum and platinum-cobalt alloys for fuel cells, we carried out a series of measurements with the electrochemical quartz crystal microbalance (EQCM) and the rotating disk electrode (RDE) in acid solution. The effects of anion adsorption on the activities for the ORR were first assessed in HClO4 and HF electrolyte solutions at various concentrations. In our previous work (Part 1), we reported that the perchlorate anion adsorbs specifically on bulk-Pt, with a Frumkin-Temkin isotherm, that is, a linear relationship between Δm and log[HClO4]. Here, we find that the specific adsorption on the Pt-skin/Pt3Co alloy was significantly stronger than that on bulk-Pt, in line with its modified electronic properties. The kinetically controlled current density j(k) for the O2 reduction at the Pt-skin/Pt3Co-RDE was about 9 times larger than that of the bulk-Pt-RDE in 0.01 M HClO4 saturated with air, but the j(k) values on Pt-skin/Pt3Co decreased with increasing [HClO4] more steeply than in the case of Pt, due to the blocking of the active sites by the specifically adsorbed ClO4(-). We have detected reversible mass changes for one or more adsorbed oxygen-containing species (Ox = O2, O, OH, H2O) on the Pt-skin/Pt3Co-EQCM and Pt-EQCM in O2-saturated and He-purged 0.01 M HClO4 solutions, in which the specific adsorption of ClO4(-) anions was negligible. The coverages of oxygen species θ(Ox) on the Pt-skin/Pt3Co in the potential range from 0.86 to 0.96 V in the O2-saturated solution were found to be larger than those on pure Pt, providing strong evidence that the higher O2 reduction activity on the Pt3Co is correlated with higher θ(Ox), contrary to the conventional view.

  11. Modeling of carbon sequestration in coal-beds: A variable saturated simulation

    International Nuclear Information System (INIS)

    Liu Guoxiang; Smirnov, Andrei V.

    2008-01-01

    Storage of carbon dioxide in deep coal seams is a profitable method to reduce the concentration of green house gases in the atmosphere while the methane as a byproduct can be extracted during carbon dioxide injection into the coal seam. In this procedure, the key element is to keep carbon dioxide in the coal seam without escaping for a long term. It is depended on many factors such as properties of coal basin, fracture state, phase equilibrium, etc., especially the porosity, permeability and saturation of the coal seam. In this paper, a variable saturation model was developed to predict the capacity of carbon dioxide sequestration and coal-bed methane recovery. This variable saturation model can be used to track the saturation variability with the partial pressures change caused by carbon dioxide injection. Saturation variability is a key factor to predict the capacity of carbon dioxide storage and methane recovery. Based on this variable saturation model, a set of related variables including capillary pressure, relative permeability, porosity, coupled adsorption model, concentration and temperature equations were solved. From results of the simulation, historical data agree with the variable saturation model as well as the adsorption model constructed by Langmuir equations. The Appalachian basin, as an example, modeled the carbon dioxide sequestration in this paper. The results of the study and the developed models can provide the projections for the CO 2 sequestration and methane recovery in coal-beds within different regional specifics

  12. The responses of photosynthesis and oxygen consumption to short-term changes in temperature and irradiance in a cyanobacterial mat (Ebro Delta, Spain)

    DEFF Research Database (Denmark)

    Epping, E.H.G.; Kühl, Michael

    2000-01-01

    We have evaluated the effects of short-term changes in incident irradiance and temperature on oxygenic photosynthesis and oxygen consumption in a hypersaline cyanobacterial mat from the Ebro Delta, Spain, in which Microcoleus chthonoplastes was the dominant phototrophic organism. The mat was incu......We have evaluated the effects of short-term changes in incident irradiance and temperature on oxygenic photosynthesis and oxygen consumption in a hypersaline cyanobacterial mat from the Ebro Delta, Spain, in which Microcoleus chthonoplastes was the dominant phototrophic organism. The mat...... was incubated in the laboratory at 15, 20, 25 and 308C at incident irradiances ranging from 0 to 1000 mmol photons m22 s21. Oxygen microsensors were used to measure steady-state oxygen profiles and the rates of gross photosynthesis, which allowed the calculation of areal gross photosynthesis, areal net oxygen...... production, and oxygen consumption in the aphotic layer of the mat. The lowest surface irradiance that resulted in detectable rates of gross photosynthesis increased with increasing temperature from 50 mmol photons m22 s21 at 158C to 500 mmol photons m22 s21 at 308C. These threshold irradiances were also...

  13. Clinical oxygen enhancement ratio of tumors in carbon ion radiotherapy: the influence of local oxygenation changes

    DEFF Research Database (Denmark)

    Antonovic, Laura; Lindblom, Emely; Dasu, Alexandru

    2014-01-01

    , using the repairable–conditionally repairable (RCR) damage model with parameters for human salivary gland tumor cells. The clinical oxygen enhancement ratio (OER) was defined as the ratio of doses required for a tumor control probability of 50% for hypoxic and well-oxygenated tumors. The resulting OER...... was well above unity for all fractionations. For the hypoxic tumor, the tumor control probability was considerably higher if LOCs were assumed, rather than static oxygenation. The beneficial effect of LOCs increased with the number of fractions. However, for very low fraction doses, the improvement related...... to LOCs did not compensate for the increase in total dose required for tumor control. In conclusion, our results suggest that hypoxia can influence the outcome of carbon ion radiotherapy because of the non-negligible oxygen effect at the low LETs in the SOBP. However, if LOCs occur, a relatively high...

  14. Probing adsorption phenomena on a single crystal Pt-alloy surface under oxygen reduction reaction conditions

    International Nuclear Information System (INIS)

    Bondarenko, Alexander S.; Stephens, Ifan E.L.; Bech, Lone; Chorkendorff, Ib

    2012-01-01

    Highlights: ► Impedance spectroscopy of Cu/Pt(1 1 1) near-surface alloy and Pt(1 1 1). ► Presence of oxygen changes little the adsorption dynamics. ► Adsorption dynamics similar on alloy and Pt(1 1 1). ► Electrosorption phenomena on alloy shifted in potential, relative to Pt(1 1 1). - Abstract: The adsorption dynamics of *OH and *O species at Pt(1 1 1) and Cu/Pt(1 1 1) near-surface alloy (NSA) surfaces in oxygen-free and O 2 -saturated 0.1 M HClO 4 was investigated. Subsurface Cu modifies the electronic structure at the Pt(1 1 1) surface resulting in weaker bonding to adsorbates like *OH, *H or *O. This provides a basis for the high oxygen reduction activity of the NSA, as predicted by density functional theory calculations. The shift in *OH adsorption of around 0.16 V towards more positive potentials can be clearly monitored in absence of O 2 and under the oxygen reduction reaction (ORR) conditions for the Cu/Pt(1 1 1) NSA. In both cases, for Pt(1 1 1) and NSA, the *OH(*O) adsorption dynamics is very similar in the absence of oxygen and under ORR conditions. Therefore, theoretical assumptions about the coverage of adsorbates in the absence of oxygen can be reasonably extrapolated to the situation when oxygen reduction takes place at the surface. A ∼5-fold improvement in the ORR activity over the Pt(1 1 1) at 0.9 V (RHE) was measured for the Cu/Pt(1 1 1) near-surface alloy.

  15. Time required for partial pressure of arterial oxygen equilibration during mechanical ventilation after a step change in fractional inspired oxygen concentration.

    Science.gov (United States)

    Cakar, N; Tuŏrul, M; Demirarslan, A; Nahum, A; Adams, A; Akýncý, O; Esen, F; Telci, L

    2001-04-01

    To determine the time required for the partial pressure of arterial oxygen (PaO2) to reach equilibrium after a 0.20 increment or decrement in fractional inspired oxygen concentration (FIO2) during mechanical ventilation. A multi-disciplinary ICU in a university hospital. Twenty-five adult, non-COPD patients with stable blood gas values (PaO2/FIO2 > or = 180 on the day of the study) on pressure-controlled ventilation (PCV). Following a baseline PaO2 (PaO2b) measurement at FIO2 = 0.35, the FIO2 was increased to 0.55 for 30 min and then decreased to 0.35 without any other change in ventilatory parameters. Sequential blood gas measurements were performed at 3, 5, 7, 9, 11, 15, 20, 25 and 30 min in both periods. The PaO2 values measured at the 30th min after a step change in FIO2 (FIO2 = 0.55, PaO2[55] and FIO2 = 0.35, PaO2[35]) were accepted as representative of the equilibrium values for PaO2. Each patient's rise and fall in PaO2 over time, PaO2(t), were fitted to the following respective exponential equations: PaO2b + (PaO2[55]-PaO2b)(1-e-kt) and PaO2[55] + (PaO2[35]-PaO2[55])(e-kt) where "t" refers to time, PaO2[55] and PaO2[35] are the final PaO2 values obtained at a new FIO2 of 0.55 and 0.35, after a 0.20 increment and decrement in FIO2, respectively. Time constant "k" was determined by a non-linear fitting curve and 90% oxygenation times were defined as the time required to reach 90% of the final equilibrated PaO2 calculated by using the non-linear fitting curves. Time constant values for the rise and fall periods were 1.01 +/- 0.71 min-1, 0.69 +/- 0.42 min-1, respectively, and 90% oxygenation times for rises and falls in PaO2 periods were 4.2 +/- 4.1 min-1 and 5.5 +/- 4.8 min-1, respectively. There was no significant difference between the rise and fall periods for the two parameters (p > 0.05). We conclude that in stable patients ventilated with PCV, after a step change in FIO2 of 0.20, 5-10 min will be adequate for obtaining a blood gas sample to measure a Pa

  16. Oxidative degradation of alternative gasoline oxygenates in aqueous solution by ultrasonic irradiation: Mechanistic study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Duk Kyung, E-mail: dkim@aum.edu [Department of Physical Science, Auburn University Montgomery, Montgomery, AL 36117 (United States); O' Shea, Kevin E., E-mail: osheak@fiu.edu [Department of Chemistry and Biochemistry, Florida International University, University Park, Miami, FL 33199 (United States); Cooper, William J. [Department of Civil and Environmental Engineering, Urban Water Research Center, University of California Irvine, Irvine, CA 92697-2175 (United States)

    2012-07-15

    Widespread pollution has been associated with gasoline oxygenates of branched ethers methyl tert-butyl ether (MTBE), di-isopropyl ether (DIPE), ethyl tert-butyl ether (ETBE), and tert-amyl ether (TAME) which enter groundwater. The contaminated plume develops rapidly and treatment for the removal/destruction of these ethers is difficult when using conventional methods. Degradation of MTBE, with biological methods and advanced oxidation processes, are rather well known; however, fewer studies have been reported for degradation of alternative oxygenates. Degradation of alternative gasoline oxygenates (DIPE, ETBE, and TAME) by ultrasonic irradiation in aqueous oxygen saturation was investigated to elucidate degradation pathways. Detailed degradation mechanisms are proposed for each gasoline oxygenate. The common major degradation pathways are proposed to involve abstraction of {alpha}-hydrogen atoms by hydroxyl radicals generated during ultrasound cavitation and low temperature pyrolytic degradation of ETBE and TAME. Even some of the products from {beta}-H abstraction overlap with those from high temperature pyrolysis, the effect of {beta}-H abstraction was not shown clearly from product study because of possible 1,5 H-transfer inside cavitating bubbles. Formation of hydrogen peroxide and organic peroxides was also determined during sonolysis. These data provide a better understanding of the degradation pathways of gasoline oxygenates by sonolysis in aqueous solutions. The approach may also serve as a model for others interested in the details of sonolysis. - Highlights: Black-Right-Pointing-Pointer Gasoline oxygenates (ETBE, TAME, DIPE) were completely degraded after 6 hours under ultrasonic irradiation in O{sub 2} saturation. Black-Right-Pointing-Pointer The major degradation pathways were proposed to involve abstraction of {alpha}-hydrogen atoms by hydroxyl radicals and low temperature pyrolytic degradation. Black-Right-Pointing-Pointer The effect of {beta

  17. Fault tolerant control of systems with saturations

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik

    2013-01-01

    This paper presents framework for fault tolerant controllers (FTC) that includes input saturation. The controller architecture known from FTC is based on the Youla-Jabr-Bongiorno-Kucera (YJBK) parameterization is extended to handle input saturation. Applying this controller architecture in connec......This paper presents framework for fault tolerant controllers (FTC) that includes input saturation. The controller architecture known from FTC is based on the Youla-Jabr-Bongiorno-Kucera (YJBK) parameterization is extended to handle input saturation. Applying this controller architecture...... in connection with faulty systems including input saturation gives an additional YJBK transfer function related to the input saturation. In the fault free case, this additional YJBK transfer function can be applied directly for optimizing the feedback loop around the input saturation. In the faulty case......, the design problem is a mixed design problem involved both parametric faults and input saturation....

  18. Effects of whole body UV-irradiation on oxygen delivery from the erythrocyte

    International Nuclear Information System (INIS)

    Humpeler, E.; Mairbaeurl, H.; Hoenigsmann, H.

    1982-01-01

    In 16 healthy caucasian volunteers (mean age: 22.2 years) the influence of whole body UV-irradiation on the oxygen transport properties of erythrocytes was investigated. Four hours after irradiation with UV (using the minimal erythema dose, MED) no variation of haemoglobin concentration, hematocrit, mean corpuscular haemoglobin concentration, pH or standard bicarbonate could be found, whereas inorganic plasma phosphate (Psub(i)), calcium, the intraerythrocytic 2,3-diphosphoglycerate (2,3-DPG), the activity of erythrocytic phosphofructokinase (PFK) and pyruvatekinase (PK) increased significantly. The half saturation tension of oxygen (P 50 -value) tended to increase. The increase of Psub(i) causes - via a stimulation of the glycolytic pathway - an increase in 2,3-DPG concentration and thus results in a shift of the oxygen dissociation curve. It is therefore possible to enhance tissue oxygenation by whole body UV-irradiation. (orig.)

  19. Sulfur concentration at sulfide saturation (SCSS) in magmatic silicate melts

    Science.gov (United States)

    Liu, Yanan; Samaha, Naji-Tom; Baker, Don R.

    2007-04-01

    The sulfur concentration in silicate melts at sulfide saturation (SCSS) was experimentally investigated in a temperature range from 1150 to 1450 °C and a pressure range from 500 MPa to 1 GPa in a piston-cylinder apparatus. The investigated melt compositions varied from rhyolitic to basaltic and water concentrations varied from 0 to ˜9 wt%. All experiments were saturated with FeS melt or pyrrhotite crystals. Temperature was confirmed to have a positive effect on the SCSS. Experimental oxygen fugacities were either near the carbon-carbon monoxide buffer or one log unit above the nickel-nickel oxide buffer, and found to positively affect the SCSS. Combining our results with data from the literature we constructed a model to predict the SCSS in melts ranging in composition from komatiitic to rhyolitic, with water concentrations from 0 to 9 wt%, at pressures from 1 bar to 9 GPa and oxygen fugacities between ˜2 log units below the fayalite-magnetite-quartz buffer to ˜2 log units above it. The coefficients were obtained by multiple linear regression of experimental data and the best model found for the prediction of the SCSS is: ln(Sinppm)=11.35251-{4454.6}/{T}-0.03190{P}/{T}+0.71006ln(MFM)-1.98063[(MFM)(XO)]+0.21867ln(XO)+0.36192lnX where P is in bar, T is in K, MFM is a compositional parameter describing the melt based upon cation mole fractions: MFM={Na+K+2(Ca+Mg+Fe)}/{Si×(Al+Fe)}, XO is the mole fraction of water in the melt, and X is the mole fraction of FeO in the melt. This model was independently tested against experiments performed on anhydrous and hydrous melts in the temperature range from 800 to 1800 °C and 1-9 GPa. The model typically predicts the measured values of the natural log of the SCSS (in ppm) for komatiitic to rhyolitic (˜42 to ˜74 wt% SiO 2) melts to within 5% relative, but is less accurate for high-silica (>76 wt% SiO 2) rhyolites, especially those with molar ratios of iron to sulfur below 2. We demonstrate how this model can be used with

  20. Multi-modal in vivo imaging of brain blood oxygenation, blood flow and neural calcium dynamics during acute seizures

    Science.gov (United States)

    Ringuette, Dene; Jeffrey, Melanie A.; Carlen, Peter L.; Levi, Ofer

    2016-03-01

    Dysfunction of the vascular endothelium has been implicated in the development of epilepsy. To better understand the relation between vascular function and seizure and provide a foundation for interpreting results from functional imaging in chronic disease models, we investigate the relationship between intracellular calcium dynamics and local cerebral blood flow and blood oxygen saturation during acute seizure-like events and pharmacological seizure rescue. To probe the relation between the aforementioned physiological markers in an acute model of epilepsy in rats, we integrated three different optical modalities together with electrophysiological recordings: Laser speckle contrast imaging (LSCI) was used to study changes in flow speeds, Intrinsic optical signal imaging (IOSI) was used to monitor changes in oxygenated, de-oxygenated, and total hemoglobin concentration, and Calcium-sensitive dye imaging was used to monitor intracellular calcium dynamics. We designed a dedicated cortical flow chamber to remove superficial blood and dye resulting from the injection procedure, which reduced spurious artifacts. The near infrared light used for IOSI and LSCI was delivered via a light pipe integrated with the flow chamber to minimize the effect of fluid surface movement on illumination stability. Calcium-sensitive dye was injected via a glass electrode used for recording the local field potential. Our system allowed us to observe and correlate increases in intracellular calcium, blood flow and blood volume during seizure-like events and provide a quantitative analysis of neurovascular coupling changes associated with seizure rescue via injection of an anti-convulsive agent.

  1. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping improves systemic and cerebral oxygenation in preterm lambs.

    Directory of Open Access Journals (Sweden)

    Graeme R Polglase

    Full Text Available As measurement of arterial oxygen saturation (SpO2 is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known.We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs.Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2 were measured continuously in apnoeic preterm lambs (126±1 day gestation. Positive pressure ventilation was initiated either 1 prior to umbilical cord clamping, or 2 after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping.Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping.The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  2. Temperature dependence of sulfide and sulfate solubility in olivine-saturated basaltic magmas

    Science.gov (United States)

    Beermann, O.; Botcharnikov, R. E.; Holtz, F.; Diedrich, O.; Nowak, M.

    2011-12-01

    The sulfur concentration at pyrrhotite- and anhydrite-saturation in primitive hydrous basaltic melt of the 2001-2002 eruption of Mt. Etna was determined at 200 MPa, T = 1050-1250 °C and at log fO 2 from FMQ to FMQ+2.2 (FMQ is Fayalite-Magnetite-Quartz oxygen buffer). At 1050 °C Au sample containers were used. A double-capsule technique, using a single crystal olivine sample container closed with an olivine piston, embedded in a sealed Au 80Pd 20 capsule, was developed to perform experiments in S-bearing hydrous basaltic systems at T > 1050 °C. Pyrrhotite is found to be a stable phase coexisting with melt at FMQ-FMQ+0.3, whereas anhydrite is stable at FMQ+1.4-FMQ+2.2. The S concentration in the melt increases almost linearly from 0.12 ± 0.01 to 0.39 ± 0.02 wt.% S at FeS-saturation and from 0.74 ± 0.01 to 1.08 ± 0.04 wt.% S at anhydrite-saturation with T ranging from 1050-1250 °C. The relationships between S concentration at pyrrhotite and/or anhydrite saturation, MgO content of the olivine-saturated melt, T, and log fO 2 observed in this study and from previous data are used to develop an empirical model for estimating the magmatic T and fO 2 from the S and MgO concentrations of H 2O-bearing olivine-saturated basaltic melts. The model can also be used to determine maximum S concentrations, if fO 2 and MgO content of the melt are known. The application of the model to compositions of melt inclusions in olivines from Mt. Etna indicates that the most primitive magmas trapped in inclusions might have been stored at log fO 2 slightly higher than FMQ+1 and at T = 1100-1150 °C, whereas more evolved melts could have been trapped at T ⩽ 1100 °C. These values are in a good agreement with the estimates obtained by other independent methods reported in the literature.

  3. Correlation of oxygenation and perfusion sensitive MRI with invasive micro probe measurements in healthy mice brain

    International Nuclear Information System (INIS)

    Sedlacik, Jan; Fiehler, Jens; Reitz, Matthias; Schmidt, Nils O.; Bolar, Divya S.; Adalsteinsson, Elfar

    2015-01-01

    The non-invasive assessment of (patho-)physiological parameters such as, perfusion and oxygenation, is of great importance for the characterization of pathologies e.g., tumors, which may be helpful to better predict treatment response and potential outcome. To better understand the influence of physiological parameters on the investigated oxygenation and perfusion sensitive MRI methods, MRI measurements were correlated with subsequent invasive micro probe measurements during free breathing conditions of air, air+10% CO2 and 100% O2 in healthy mice brain. MRI parameters were the irreversible (R2), reversible (R2') and effective (R2*) transverse relaxation rates, venous blood oxygenation level assessed by quantitative blood oxygenation level dependent (qBOLD) method and cerebral blood flow (CBF) assessed by arterial spin labeling (ASL) using a 7T small animal MRI scanner. One to two days after MRI, tissue perfusion and pO2 were measured by Laser-Doppler flowmetry and fluorescence quenching micro probes, respectively. The tissue pO2 values were converted to blood oxygen saturation by using the Hill equation. The animals were anesthetized by intra peritoneal injection of ketamine-xylazine-acepromazine (10-2-0.3 mg/ml.kg). Results for normal/hypercapnia/hyperoxia conditions were: R2[s and -1] = 20.7/20.4/20.1, R2*[s and -1] = 31.6/29.6/25.9, R2'[s and 1] = 10.9/9.2/5.7, qBOLD venous blood oxygenation level = 0.43/0.51/0.56, CBF[ml.min and -1.100g and -1] = 70.6/105.5/81.8, Laser-Doppler flowmetry[a.u.] = 89.2/120.2/90.6 and pO2[mmHg] = 6.3/32.3/46.7. All parameters were statistically significantly different with P < 0.001 between all breathing conditions. All MRI and the corresponding micro probe measurements were also statistically significantly (P ≤ 0.03) correlated with each other. However, converting the tissue pO2 to blood oxygen saturation = 0.02/0.34/0.63, showed only very limited agreement with the qBOLD venous blood oxygenation level. We found good

  4. Correlation of oxygenation and perfusion sensitive MRI with invasive micro probe measurements in healthy mice brain

    Energy Technology Data Exchange (ETDEWEB)

    Sedlacik, Jan; Fiehler, Jens [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Neuroradiology; Reitz, Matthias; Schmidt, Nils O. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Neurosurgery; Bolar, Divya S. [Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA (United States). Radiology; Adalsteinsson, Elfar [Massachusetts Institute of Technology, Cambridge, MA (United States). Electrical Engineering and Computer Science

    2015-05-01

    The non-invasive assessment of (patho-)physiological parameters such as, perfusion and oxygenation, is of great importance for the characterization of pathologies e.g., tumors, which may be helpful to better predict treatment response and potential outcome. To better understand the influence of physiological parameters on the investigated oxygenation and perfusion sensitive MRI methods, MRI measurements were correlated with subsequent invasive micro probe measurements during free breathing conditions of air, air+10% CO2 and 100% O2 in healthy mice brain. MRI parameters were the irreversible (R2), reversible (R2') and effective (R2*) transverse relaxation rates, venous blood oxygenation level assessed by quantitative blood oxygenation level dependent (qBOLD) method and cerebral blood flow (CBF) assessed by arterial spin labeling (ASL) using a 7T small animal MRI scanner. One to two days after MRI, tissue perfusion and pO2 were measured by Laser-Doppler flowmetry and fluorescence quenching micro probes, respectively. The tissue pO2 values were converted to blood oxygen saturation by using the Hill equation. The animals were anesthetized by intra peritoneal injection of ketamine-xylazine-acepromazine (10-2-0.3 mg/ml.kg). Results for normal/hypercapnia/hyperoxia conditions were: R2[s {sup and} -1] = 20.7/20.4/20.1, R2*[s {sup and} -1] = 31.6/29.6/25.9, R2'[s {sup and} 1] = 10.9/9.2/5.7, qBOLD venous blood oxygenation level = 0.43/0.51/0.56, CBF[ml.min {sup and} -1.100g {sup and} -1] = 70.6/105.5/81.8, Laser-Doppler flowmetry[a.u.] = 89.2/120.2/90.6 and pO2[mmHg] = 6.3/32.3/46.7. All parameters were statistically significantly different with P < 0.001 between all breathing conditions. All MRI and the corresponding micro probe measurements were also statistically significantly (P ≤ 0.03) correlated with each other. However, converting the tissue pO2 to blood oxygen saturation = 0.02/0.34/0.63, showed only very limited agreement with the qBOLD venous blood

  5. Empirical algorithms to predict aragonite saturation state

    Science.gov (United States)

    Turk, Daniela; Dowd, Michael

    2017-04-01

    Novel sensor packages deployed on autonomous platforms (Profiling Floats, Gliders, Moorings, SeaCycler) and biogeochemical models have a potential to increase the coverage of a key water chemistry variable, aragonite saturation state (ΩAr) in time and space, in particular in the under sampled regions of global ocean. However, these do not provide the set of inorganic carbon measurements commonly used to derive ΩAr. There is therefore a need to develop regional predictive models to determine ΩAr from measurements of commonly observed or/and non carbonate oceanic variables. Here, we investigate predictive skill of several commonly observed oceanographic variables (temperature, salinity, oxygen, nitrate, phosphate and silicate) in determining ΩAr using climatology and shipboard data. This will allow us to assess potential for autonomous sensors and biogeochemical models to monitor ΩAr regionally and globally. We apply the regression models to several time series data sets and discuss regional differences and their implications for global estimates of ΩAr.

  6. Shifts in coastal sediment oxygenation cause pronounced changes in microbial community composition and associated metabolism.

    Science.gov (United States)

    Broman, Elias; Sjöstedt, Johanna; Pinhassi, Jarone; Dopson, Mark

    2017-08-09

    A key characteristic of eutrophication in coastal seas is the expansion of hypoxic bottom waters, often referred to as 'dead zones'. One proposed remediation strategy for coastal dead zones in the Baltic Sea is to mix the water column using pump stations, circulating oxygenated water to the sea bottom. Although microbial metabolism in the sediment surface is recognized as key in regulating bulk chemical fluxes, it remains unknown how the microbial community and its metabolic processes are influenced by shifts in oxygen availability. Here, coastal Baltic Sea sediments sampled from oxic and anoxic sites, plus an intermediate area subjected to episodic oxygenation, were experimentally exposed to oxygen shifts. Chemical, 16S rRNA gene, metagenomic, and metatranscriptomic analyses were conducted to investigate changes in chemistry fluxes, microbial community structure, and metabolic functions in the sediment surface. Compared to anoxic controls, oxygenation of anoxic sediment resulted in a proliferation of bacterial populations in the facultative anaerobic genus Sulfurovum that are capable of oxidizing toxic sulfide. Furthermore, the oxygenated sediment had higher amounts of RNA transcripts annotated as sqr, fccB, and dsrA involved in sulfide oxidation. In addition, the importance of cryptic sulfur cycling was highlighted by the oxidative genes listed above as well as dsvA, ttrB, dmsA, and ddhAB that encode reductive processes being identified in anoxic and intermediate sediments turned oxic. In particular, the intermediate site sediments responded differently upon oxygenation compared to the anoxic and oxic site sediments. This included a microbial community composition with more habitat generalists, lower amounts of RNA transcripts attributed to methane oxidation, and a reduced rate of organic matter degradation. These novel data emphasize that genetic expression analyses has the power to identify key molecular mechanisms that regulate microbial community responses

  7. Singlet oxygen produced by quasi-continuous photo-excitation of hypericin in dimethyl-sulfoxide

    Energy Technology Data Exchange (ETDEWEB)

    Varchola, J.; Želonková, K. [Department of Biophysics, Faculty of Science, P. J. Šafárik University, Jesenná 5, 041 54 Košice (Slovakia); Chorvat Jr, D. [International Laser Centre, Ilkovicova 3, 841 05 Bratislava (Slovakia); Jancura, D. [Department of Biophysics, Faculty of Science, P. J. Šafárik University, Jesenná 5, 041 54 Košice (Slovakia); Center for Interdisciplinary Biosciences, Faculty of Science, P. J. Šafárik University, Jesenná 5, 041 54 Košice (Slovakia); Miskovsky, P. [Department of Biophysics, Faculty of Science, P. J. Šafárik University, Jesenná 5, 041 54 Košice (Slovakia); International Laser Centre, Ilkovicova 3, 841 05 Bratislava (Slovakia); Center for Interdisciplinary Biosciences, Faculty of Science, P. J. Šafárik University, Jesenná 5, 041 54 Košice (Slovakia); and others

    2016-09-15

    Singlet oxygen (O{sub 2}({sup 1}Δ{sub g})) production by photo-excited hypericin (Hyp) dissolved in dimethyl-sulfoxide (DMSO) was studied by means of time-resolved phosphorescence measurements. In order to minimize photo-bleaching, the samples were excited in quasi-continuous mode using long-pulse (35 μs) laser excitation. The measured lifetime of singlet oxygen is τ{sub Δ}=5.5±0.3 μs. This result helps to resolve the discrepancy existing in the literature concerning singlet oxygen lifetime in DMSO. The obtained quantum yield of singlet oxygen photosensitized by Hyp in air-saturated DMSO is Φ{sub Δ}=0.4±0.03. The rate constant for Hyp triplet state depopulation in reaction with ground state molecular oxygen is measured to be k{sub q}=1.6±0.3×10{sup 9} M{sup −1} s{sup −1}.

  8. Evaluation of Optimum Moisture Content for Composting of Beef Manure and Bedding Material Mixtures Using Oxygen Uptake Measurement

    Directory of Open Access Journals (Sweden)

    Eunjong Kim

    2016-05-01

    Full Text Available Moisture content influences physiological characteristics of microbes and physical structure of solid matrices during composting of animal manure. If moisture content is maintained at a proper level, aerobic microorganisms show more active oxygen consumption during composting due to increased microbial activity. In this study, optimum moisture levels for composting of two bedding materials (sawdust, rice hull and two different mixtures of bedding and beef manure (BS, Beef cattle manure+sawdust; BR, Beef cattle manure+rice hull were determined based on oxygen uptake rate measured by a pressure sensor method. A broad range of oxygen uptake rates (0.3 to 33.3 mg O2/g VS d were monitored as a function of moisture level and composting feedstock type. The maximum oxygen consumption of each material was observed near the saturated condition, which ranged from 75% to 98% of water holding capacity. The optimum moisture content of BS and BR were 70% and 57% on a wet basis, respectively. Although BS’s optimum moisture content was near saturated state, its free air space kept a favorable level (above 30% for aerobic composting due to the sawdust’s coarse particle size and bulking effect.

  9. Evaluation of Optimum Moisture Content for Composting of Beef Manure and Bedding Material Mixtures Using Oxygen Uptake Measurement.

    Science.gov (United States)

    Kim, Eunjong; Lee, Dong-Hyun; Won, Seunggun; Ahn, Heekwon

    2016-05-01

    Moisture content influences physiological characteristics of microbes and physical structure of solid matrices during composting of animal manure. If moisture content is maintained at a proper level, aerobic microorganisms show more active oxygen consumption during composting due to increased microbial activity. In this study, optimum moisture levels for composting of two bedding materials (sawdust, rice hull) and two different mixtures of bedding and beef manure (BS, Beef cattle manure+sawdust; BR, Beef cattle manure+rice hull) were determined based on oxygen uptake rate measured by a pressure sensor method. A broad range of oxygen uptake rates (0.3 to 33.3 mg O2/g VS d) were monitored as a function of moisture level and composting feedstock type. The maximum oxygen consumption of each material was observed near the saturated condition, which ranged from 75% to 98% of water holding capacity. The optimum moisture content of BS and BR were 70% and 57% on a wet basis, respectively. Although BS's optimum moisture content was near saturated state, its free air space kept a favorable level (above 30%) for aerobic composting due to the sawdust's coarse particle size and bulking effect.

  10. Should direct measurements of tumor oxygenation relate to the radiobiological hypoxic fraction of a tumor?

    International Nuclear Information System (INIS)

    Fenton, Bruce M.; Kiani, Mohammad F.; Siemann, Dietmar W.

    1995-01-01

    Purpose: Numerous previous studies have attempted to relate the radiobiological hypoxic fraction (HF) to direct measures of tumor oxygenation such as HbO 2 saturations, tumor pO 2 levels, or hypoxic cell labeling. Although correlations have been found within tumor lines, no overall relationships were seen across tumor lines. The current objective was to examine the effect on HF of changes in the fractions of the oxygenated and anoxic tumor cells that remain clonogenic. Methods and Materials: A mathematical model was developed that relates the HF to direct measures of tumor oxygenation. The primary assumptions were that: (a) the tumor is divided into distinct compartments of either fully oxygenated or fully anoxic cells, and (b) the survival of the oxygenated cells is negligible compared to that of the anoxic cells. Based on these assumptions, the HF is plotted as a function of the fractions of clonogenic or nonclonogenic, and oxygenated or anoxic cells. Results: If all cells are clonogenic, then the HF equals the fraction of anoxic cells. If a higher fraction of anoxic than oxygenated cells are nonclonogenic, then the HF will be overestimated by the fraction of the tumor measured to be anoxic using direct measuring techniques. If a higher fraction of the oxygenated than anoxic cells are nonclonogenic, the HF will be underestimated by the fraction of anoxic cells. Conclusion: Correlations between the HF and direct measures of tumor oxygenation have been described within tumor lines evaluated under different physiological condition. However, such relationships can be totally unpredictable between different tumors if the fraction of the anoxic cells that is clonogenic varies substantially. Clearly, if tumor anoxia cannot be detected using direct measures, this is an accurate indication that the tumor is well oxygenated. When tumor anoxia is present, however, the conclusions are ambiguous. Even when a small fraction of the tumor is measured as anoxic, direct measures

  11. A study on change in the center frequency depending on the fat content and on change in the fat saturation image with the use of a self-manufactured phantom depending on the center frequency adjustment method in an MRI breast scan

    Science.gov (United States)

    Kim, Chang-Bok; Dong, Kyung-Rae; Gho, Hee-Jin; Chung, Woon-Kwan; Joo, Kyu-Ji; Kim, Young-Jae

    2013-12-01

    This study examined the changes in the center frequency according to the fat content the using a self-manufactured phantom. In addition, the change in the fat saturation image according to when the center frequency was applied automatically or adjusted manually was analyzed to determine the importance of a manual adjustment of the center frequency. Distilled water and animal fat were solidified in a 10-ml syringe to manufacture nine phantoms for each condition (18 in total). A MR scanner at 1.5 Tesla was used to obtain a T1-weighted three dimensional fast low-angle shot (T1 3D FLASH) dynamic fat saturation image according to the spectral attenuated inversion recovery(SPAIR) method. The images obtained were classified into the following before analyzing the center frequencies for each image: Test A (image where fat was not saturated), Test B (image where fat was saturated in an automatic adjustment of the center frequency), and Test C (image where fat was saturated in a manual adjustment of the center frequency). The signal intensity (SI) values of water, fat and background were measured to calculate the signal to noise ratio (SNR) before examining the difference in the SNRs of water and fat (SNR difference = water SNR — fat SNR). The mean center frequency in Tests A, B and C was 63.631179 MHz when the fat content was 70% or lower. The mean center frequency for Tests A and B was 63.631002 MHz when the fat content was 80% or higher, which was 226 Hz lower than that for Test C (63.631228 MHz). The water SIs of Tests A, B and C with increasing fat content showed a pattern of change similar to that of the fat SIs of Tests A and C. On the other hand, the fat SI of Test B was similar to that of Test A when the fat content was 80%, which showed a large difference in change. The water SNRs of Tests A, B and C, and the fat SNR and SNR differences of Tests A and C showed similar changes according to the fat content. The difference between the fat SNR and the SNR of Test B

  12. Seasonal Oxygen Dynamics in a Thermokarst Bog in Interior Alaska: Implications for Rates of Methane Oxidation

    Science.gov (United States)

    Neumann, R. B.; Moorberg, C.; Wong, A.; Waldrop, M. P.; Turetsky, M. R.

    2015-12-01

    Methane is a potent greenhouse gas, and wetlands represent the largest natural source of methane to the atmosphere. However, much of the methane generated in anoxic wetlands never gets emitted to the atmosphere; up to >90% of generated methane can get oxidized to carbon dioxide. Thus, oxidation is an important methane sink and changes in the rate of methane oxidation can affect wetland methane emissions. Most methane is aerobically oxidized at oxic-anoxic interfaces where rates of oxidation strongly depend on methane and oxygen concentrations. In wetlands, oxygen is often the limiting substrate. To improve understanding of belowground oxygen dynamics and its impact on methane oxidation, we deployed two planar optical oxygen sensors in a thermokarst bog in interior Alaska. Previous work at this site indicated that, similar to other sites, rates of methane oxidation decrease over the growing season. We used the sensors to track spatial and temporal patterns of oxygen concentrations over the growing season. We coupled these in-situ oxygen measurements with periodic oxygen injection experiments performed against the sensor to quantify belowground rates of oxygen consumption. We found that over the season, the thickness of the oxygenated water layer at the peatland surface decreased. Previous research has indicated that in sphagnum-dominated peatlands, like the one studied here, rates of methane oxidation are highest at or slightly below the water table. It is in these saturated but oxygenated locations that both methane and oxygen are available. Thus, a seasonal reduction in the thickness of the oxygenated water layer could restrict methane oxidation. The decrease in thickness of the oxygenated layer coincided with an increase in the rate of oxygen consumption during our oxygen injection experiments. The increase in oxygen consumption was not explained by temperature; we infer it was due to an increase in substrate availability for oxygen consuming reactions and

  13. Noninvasive optical quantification of absolute blood flow, blood oxygenation, and oxygen consumption rate in exercising skeletal muscle

    Science.gov (United States)

    Gurley, Katelyn; Shang, Yu; Yu, Guoqiang

    2012-07-01

    This study investigates a method using novel hybrid diffuse optical spectroscopies [near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS)] to obtain continuous, noninvasive measurement of absolute blood flow (BF), blood oxygenation, and oxygen consumption rate (\\Vdot O2) in exercising skeletal muscle. Healthy subjects (n=9) performed a handgrip exercise to increase BF and \\Vdot O2 in forearm flexor muscles, while a hybrid optical probe on the skin surface directly monitored oxy-, deoxy-, and total hemoglobin concentrations ([HbO2], [Hb], and THC), tissue oxygen saturation (StO2), relative BF (rBF), and relative oxygen consumption rate (r\\Vdot O2). The rBF and r\\Vdot O2 signals were calibrated with absolute baseline BF and \\Vdot O2 obtained through venous and arterial occlusions, respectively. Known problems with muscle-fiber motion artifacts in optical measurements during exercise were mitigated using a novel gating algorithm that determined muscle contraction status based on control signals from a dynamometer. Results were consistent with previous findings in the literature. This study supports the application of NIRS/DCS technology to quantitatively evaluate hemodynamic and metabolic parameters in exercising skeletal muscle and holds promise for improving diagnosis and treatment evaluation for patients suffering from diseases affecting skeletal muscle and advancing fundamental understanding of muscle and exercise physiology.

  14. Combining central venous-to-arterial partial pressure of carbon dioxide difference and central venous oxygen saturation to guide resuscitation in septic shock.

    Science.gov (United States)

    Du, Wei; Liu, Da-Wei; Wang, Xiao-Ting; Long, Yun; Chai, Wen-Zhao; Zhou, Xiang; Rui, Xi

    2013-12-01

    Central venous oxygen saturation (Scvo2) is a useful therapeutic target when treating septic shock. We hypothesized that combining Scvo2 and central venous-to-arterial partial pressure of carbon dioxide difference (△Pco2) may provide additional information about survival. We performed a retrospective analysis of 172 patients treated for septic shock. All patients were treated using goal-directed therapy to achieve Scvo2 ≥ 70%. After 6 hours of treatment, we divided patients into 4 groups based on Scvo2 (<70% or ≥ 70%) and △Pco2 (<6 mm Hg or ≥ 6 mm Hg). Overall, 28-day mortality was 35.5%. For patients in whom the Scvo2 target was not achieved at 6 hours, mortality was 50.0%, compared with 29.5% in those in whom Scvo2 exceeded 70% (P = .009). In patients with Scvo2 ≥ 70%, mortality was lower if △Pco2 was <6 mm Hg than if △Pco2 was ≥ 6 mm Hg (56.1% vs 16.1%, respectively; P < .001) and 6-hour lactate clearance was superior (0.01 ± 0.61 vs 0.21 ± 0.31, respectively; P = .016). The combination of Scvo2 and △Pco2 appears to predict outcome in critically ill patients resuscitated from septic shock better than Scvo2 alone. Patients who meet both targets appear to clear lactate more efficiently. © 2013.

  15. Hypoxemia Episodes during Day and Night and Their Impact on Oxygen Saturation Targeting in Mechanically Ventilated Preterm Infants.

    Science.gov (United States)

    Jain, Deepak; D'Ugard, Carmen; Bello, Jose; Bancalari, Eduardo; Claure, Nelson

    2018-01-01

    Hypoxemia episodes (HE) occur frequently in ventilated preterm infants and hinder the achievement of arterial oxygen saturation (SpO2) targets. These episodes may increase the risk for retinopathy of prematurity and neurodevelopmental disability. There are no data on the variation in HE and SpO2 targeting between day and night. The aim of this study was to evaluate the difference between day and night on the frequency and severity of HE and achievement of SpO2 targets. Twenty-four mechanically ventilated preterm infants with ≥4 episodes of SpO2 day (9 a.m. to 5 p.m.) were compared to the night (9 p.m. to 5 a.m.) for the frequency of HE and proportion of time within and outside the target SpO2 range (90-95%). The frequency of severe HE (SpO2 night compared to the day (1.6 ± 1.0 vs. 2.4 ± 1.3 episodes/h, p = 0.008, and 0.53 ± 0.35 vs. 0.90 ± 0.54 episodes/h, p = 0.018). There was no difference in mean episode duration. The frequency and duration of mild HE (SpO2 night compared to the day (5.9 ± 2.7 vs. 7.1 ± 2.5 episodes/h, p = 0.003, and 72 ± 15 vs. 87 ± 25 s, p = 0.01, respectively). The proportion of time in severe hypoxemia (SpO2 95%) was greater, during the night compared to the day. The mean FiO2 did not differ between day and night. In this group of infants with frequent HE, nighttime was associated with fewer episodes when compared to daytime. This is likely due to less handling and sensory stimulation during the night. The increase in time spent with hyperoxemia during the night is likely to be due to more tolerance of high SpO2 with less proactive weaning of FiO2. © 2017 S. Karger AG, Basel.

  16. Barley seed radiosensitivity following post-hydration in oxygen-, nitrogen- and nitrous oxide-saturated water, 1; Influence of caffeine and t-butyl alcohol

    Energy Technology Data Exchange (ETDEWEB)

    Singh, S.P.; Kesavan, P.C. (Jawaharlal Nehru Univ., New Delhi (India). School of Life Sciences)

    1990-06-01

    Dry ({approx}3.5 and 4.0 per cent moisture content) barley seeds were exposed to 350 Gy of {sup 60}Co-{gamma}-rays in vacuo and post-hydrated at 4degC for 8 h in O{sub 2}-, N{sub 2}-, or N{sub 2}O-saturated water. The effect of caffeine and t-butyl alcohol (t-BuOH) dissolved in the post-hydration medium on the magnitude of damage developing under these three different gaseous circumstances was studied. The post-irradiation damage and its modification by caffeine and t-BuOH was assessed in terms of 8-day-old seedling injury, peroxidase activity and total peroxides in the 8-day-old seedlings. Post-irradiation O{sub 2}-saturated hydration caused maximal 8-day-old seedling injury, and increased peroxidase activity with concomitant reduction in total peroxides. Both caffeine and t-BuOH afforded significant radioprotection against post-irradiation O{sub 2}-dependent damage. Post-irradiation N{sub 2}O-saturated hydration was even more significantly radioprotective than the N{sub 2}-saturated post-hydration. Under these circumstances, t-BuOH exerted no effect whatsoever on the N{sub 2}- and N{sub 2}O-mediated post-irradiation damage. Caffeine, on the other hand, significantly potentiated these two components of damage. A brief consideration of the physicochemical events which possibly account for the observed effects is presented. (author).

  17. Achieved versus intended pulse oximeter saturation in infants born less than 28 weeks' gestation: the AVIOx study.

    Science.gov (United States)

    Hagadorn, James I; Furey, Anne M; Nghiem, Tuyet-Hang; Schmid, Christopher H; Phelps, Dale L; Pillers, De-Ann M; Cole, Cynthia H

    2006-10-01

    The objective of this study was to document pulse oximeter saturation levels achieved in the first 4 weeks of life in infants who were born at signal-extraction oximeters for a 72-hour period in each of the first 4 weeks of life. Data were compared with the pulse oximeter saturation target range prescribed by local institutional policy. Factors that were associated with intended range compliance were identified with hierarchical modeling. Fourteen centers from 3 countries enrolled 84 infants with mean +/- SD birth weight of 863 +/- 208 g and gestational age of 26 +/- 1.4 weeks. Oxygen saturation policy limits ranged between 83% and 92% for lower limits and 92% and 98% for upper limits. For infants who received respiratory support, median pulse oximeter saturation level achieved was 95%. Center-specific medial levels were within the intended range at 12 centers. Centers maintained infants within their intended range 16% to 64% of the time but were above range 20% to 73% of the time. In hierarchical modeling, wider target ranges, higher target range upper limits, presence of a policy of setting oximeter alarms close to the target range limits, and lower gestational age were associated with improved target range compliance. Success with maintaining the intended pulse oximeter saturation range varied substantially among centers, among patients within centers, and for individual patients over time. Most noncompliance was above the intended range. Methods for improving compliance and the effect of improved compliance on neonatal outcomes require additional research.

  18. Optimization of Glucose oxidase towards oxygen independency and high mediator activity for amperometric glucose determination in diabetes analytics

    OpenAIRE

    Arango Gutierrez, Erik Uwe

    2015-01-01

    Glucose oxidase is an oxidoreductase exhibiting a high β-D-glucose specificity and high stability which renders glucose oxidase well-suited for applications in diabetes care. Nevertheless, GOx activity is highly oxygen dependent which can lead to inaccuracies in amperometric β-D-glucose determinations. Therefore a directed evolution campaign with two rounds of random mutagenesis (SeSaM followed by epPCR), site saturation mutagenesis studies, and one simultaneous site saturation library (OmniC...

  19. Oxygen concentrators performance with nitrous oxide at 50:50 volume

    Directory of Open Access Journals (Sweden)

    Jorge Ronaldo Moll

    2014-06-01

    Full Text Available Background and objectives: Few investigations have addressed the safety of oxygen from concentrators for use in anesthesia in association with nitrous oxide. This study evaluated the percent of oxygen from a concentrator in association with nitrous oxide in a semi-closed rebreathing circuit. Methods: Adult patients undergoing low risk surgery were randomly allocated into two groups, receiving a fresh gas flow of oxygen from concentrators (O293 or of oxygen from concentrators and nitrous oxide (O293N2O. The fraction of inspired oxygen and the percentage of oxygen from fresh gas flow were measured every 10 min. The ratio of FiO2/oxygen concentration delivered was compared at various time intervals and between the groups. Results: Thirty patients were studied in each group. There was no difference in oxygen from concentrators over time for both groups, but there was a significant improvement in the FiO2 (p < 0.001 for O293 group while a significant decline (p < 0.001 for O293N2O. The FiO2/oxygen ratio varied in both groups, reaching a plateau in the O293 group. Pulse oximetry did not fall below 98.5% in either group. Conclusion: The FiO2 in the mixture of O293 and nitrous oxide fell during the observation period although oxygen saturation was higher than 98.5% throughout the study. Concentrators can be considered a stable source of oxygen for use during short anesthetic procedures, either pure or in association with nitrous oxide at 50:50 volume.

  20. nitrogen saturation in stream ecosystems

    OpenAIRE

    Earl, S. R.; Valett, H. M.; Webster, J. R.

    2006-01-01

    The concept of nitrogen (N) saturation has organized the assessment of N loading in terrestrial ecosystems. Here we extend the concept to lotic ecosystems by coupling Michaelis-Menten kinetics and nutrient spiraling. We propose a series of saturation response types, which may be used to characterize the proximity of streams to N saturation. We conducted a series of short-term N releases using a tracer ((NO3)-N-15-N) to measure uptake. Experiments were conducted in streams spanning a gradient ...